DOE Office of Scientific and Technical Information (OSTI.GOV)
Jalaeian, Hamed, E-mail: hjalaeia@umn.edu; Talaie, Reza; D’Souza, Donna
PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in themore » conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cookson, Daniel T., E-mail: danielthomascookson@yahoo.co.uk; Zaman, Zubayr; Gordon-Smith, James
2011-02-15
Purpose: To investigate the reproducibility and technical and clinical success of the parallel technique of transjugular intrahepatic portosystemic shunt (TIPS) reduction in the management of refractory hepatic encephalopathy (HE). Materials and Methods: A 10-mm-diameter self-expanding stent graft and a 5-6-mm-diameter balloon-expandable stent were placed in parallel inside the existing TIPS in 8 patients via a dual unilateral transjugular approach. Changes in portosystemic pressure gradient and HE grade were used as primary end points. Results: TIPS reduction was technically successful in all patients. Mean {+-} standard deviation portosystemic pressure gradient before and after shunt reduction was 4.9 {+-} 3.6 mmHg (range,more » 0-12 mmHg) and 10.5 {+-} 3.9 mmHg (range, 6-18 mmHg). Duration of follow-up was 137 {+-} 117.8 days (range, 18-326 days). Clinical improvement of HE occurred in 5 patients (62.5%) with resolution of HE in 4 patients (50%). Single episodes of recurrent gastrointestinal hemorrhage occurred in 3 patients (37.5%). These were self-limiting in 2 cases and successfully managed in 1 case by correction of coagulopathy and blood transfusion. Two of these patients (25%) died, one each of renal failure and hepatorenal failure. Conclusion: The parallel technique of TIPS reduction is reproducible and has a high technical success rate. A dual unilateral transjugular approach is advantageous when performing this procedure. The parallel technique allows repeat bidirectional TIPS adjustment and may be of significant clinical benefit in the management of refractory HE.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp; Guenther, Rolf W., E-mail: guenther@rad.rwth-aachen.de; Isfort, Peter, E-mail: isfort@hia.rwth-aachen.de
Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of themore » TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.« less
Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia
2012-08-15
Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.« less
He, Fu-Liang; Wang, Lei; Yue, Zhen-Dong; Zhao, Hong-Wei; Liu, Fu-Quan
2014-09-07
To evaluate the feasibility of a second parallel transjugular intrahepatic portosystemic shunt (TIPS) to reduce portal venous pressure and control complications of portal hypertension. From January 2011 to December 2012, 10 cirrhotic patients were treated for complications of portal hypertension. The demographic data, operative data, postoperative recovery data, hemodynamic data, and complications were analyzed. Ten patients underwent a primary and parallel TIPS. Technical success rate was 100% with no technical complications. The mean duration of the first operation was 89.20 ± 29.46 min and the second operation was 57.0 ± 12.99 min. The mean portal system pressure decreased from 54.80 ± 4.16 mmHg to 39.0 ± 3.20 mmHg after the primary TIPS and from 44.40 ± 3.95 mmHg to 26.10 ± 4.07 mmHg after the parallel TIPS creation. The mean portosystemic pressure gradient decreased from 43.80 ± 6.18 mmHg to 31.90 ± 2.85 mmHg after the primary TIPS and from 35.60 ± 2.72 mmHg to 15.30 ± 3.27 mmHg after the parallel TIPS creation. Clinical improvement was seen in all patients after the parallel TIPS creation. One patient suffered from transient grade I hepatic encephalopathy (HE) after the primary TIPS and four patients experienced transient grade I-II after the parallel TIPS procedure. Mean hospital stay after the first and second operations were 15.0 ± 3.71 d and 16.90 ± 5.11 d (P = 0.014), respectively. After a mean 14.0 ± 3.13 mo follow-up, ascites and bleeding were well controlled and no stenosis of the stents was found. Parallel TIPS is an effective approach for controlling portal hypertension complications.
Intravascular US-Guided Portal Vein Access: Improved Procedural Metrics during TIPS Creation.
Gipson, Matthew G; Smith, Mitchell T; Durham, Janette D; Brown, Anthony; Johnson, Thor; Ray, Charles E; Gupta, Rajan K; Kondo, Kimi L; Rochon, Paul J; Ryu, Robert K
2016-08-01
To evaluate transjugular intrahepatic portosystemic shunt (TIPS) outcomes and procedure metrics with the use of three different image guidance techniques for portal vein (PV) access during TIPS creation. A retrospective review of consecutive patients who underwent TIPS procedures for a range of indications during a 28-month study period identified a population of 68 patients. This was stratified by PV access techniques: fluoroscopic guidance with or without portography (n = 26), PV marker wire guidance (n = 18), or intravascular ultrasound (US) guidance (n = 24). Procedural outcomes and procedural metrics, including radiation exposure, contrast agent volume used, procedure duration, and PV access time, were analyzed. No differences in demographic or procedural characteristics were found among the three groups. Technical success, technical success of the primary planned approach, hemodynamic success, portosystemic gradient, and procedure-related complications were not significantly different among groups. Fluoroscopy time (P = .003), air kerma (P = .01), contrast agent volume (P = .003), and total procedural time (P = .02) were reduced with intravascular US guidance compared with fluoroscopic guidance. Fluoroscopy time (P = .01) and contrast agent volume (P = .02) were reduced with intravascular US guidance compared with marker wire guidance. Intravascular US guidance of PV access during TIPS creation not only facilitates successful TIPS creation in patients with challenging anatomy, as suggested by previous investigations, but also reduces important procedure metrics including radiation exposure, contrast agent volume, and overall procedure duration compared with fluoroscopically guided TIPS creation. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.
Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J
2010-05-01
Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1/3 border of the vertebral body was measured, and 75% when distance from target to needle tip was measured. There were no major complications. Minor complications consisted of 3 cases (25%) of cement extravasation. C-arm CBCT with needle path overlay for fluoroscopic guided vertebroplasty is feasible and allows for reliable unilateral therapy of both lumbar and thoracic vertebral bodies. Extrapedicular approaches were performed safely and with good accuracy of reaching the targets.
Saad, Wael E; Lippert, Allison; Schwaner, Sandra; Al-Osaimi, Abdullah; Sabri, Saher; Saad, Nael
2014-01-01
Objectives: Endoscopic experience in the management of duodenal varices (DVs) is limited and challenging given the anatomic constraints and limited experience. The endovascular management of DVs is not yet established and the controversy of whether to manage them by decompression with a transjugular intrahepatic portosystemic shunt (TIPS) or by transvenous obliteration is unresolved. In the literature, the 6–12 month rebleeding rate of DVs after TIPS is 21-37% and after transvenous obliteration is 13%. The purpose of the study is to evaluate the clinical outcome of combined TIPS decompression and transvenous obliteration/sclerosis. Materials and Methods: This is a retrospective study (case series) of two institutions, evaluating patients who underwent TIPS and/or transvenous obliteration/sclerosis for bleeding DVs (from January 2009 to June 2013). TIPS was performed according to a standard procedure using covered stents. Transvenous obliteration (variceal sclerosis) from the systemic and/or portal venous circulation was performed utilizing 3% sodium tetradecyl sulfate foam. Transvenous obliteration was commonly augmented with coils and/or vascular plugs. Technical (technical success of establishing TIPS and completely obliterating the DVs) and clinical outcomes (rebleeding rate and survival) were evaluated. Results: Five patients with liver cirrhosis presenting with bleeding DVs were included in the study with all eventually (and coincidentally) receiving TIPS and transvenous obliteration. Two of the five patients underwent concomitant TIPS and transvenous obliteration in the same procedural setting. However, three patients underwent transvenous obliteration due to bleeding despite a patent TIPS that had been previously placed. The average time from TIPS placement to transvenous obliteration was 125 days (range: 3-324 days). After having both procedures, there was no rebleeding in the patients during a mean follow-up period of 22 months (6–50 months). Coils and/or metallic vascular plugs were used to augment the sclerosant obliteration in four of five patients. Conclusion: The combination of TIPS decompression and foam sclerosant transvenous obliteration appears to be effective in preventing rebleeding in this limited case series and compares favorably with the existing evidence for either approach [TIPS or balloon-occluded retrograde transvenous obliteration (BRTO)] alone. PMID:25558434
Saad, Wael E; Lippert, Allison; Schwaner, Sandra; Al-Osaimi, Abdullah; Sabri, Saher; Saad, Nael
2014-01-01
Endoscopic experience in the management of duodenal varices (DVs) is limited and challenging given the anatomic constraints and limited experience. The endovascular management of DVs is not yet established and the controversy of whether to manage them by decompression with a transjugular intrahepatic portosystemic shunt (TIPS) or by transvenous obliteration is unresolved. In the literature, the 6-12 month rebleeding rate of DVs after TIPS is 21-37% and after transvenous obliteration is 13%. The purpose of the study is to evaluate the clinical outcome of combined TIPS decompression and transvenous obliteration/sclerosis. This is a retrospective study (case series) of two institutions, evaluating patients who underwent TIPS and/or transvenous obliteration/sclerosis for bleeding DVs (from January 2009 to June 2013). TIPS was performed according to a standard procedure using covered stents. Transvenous obliteration (variceal sclerosis) from the systemic and/or portal venous circulation was performed utilizing 3% sodium tetradecyl sulfate foam. Transvenous obliteration was commonly augmented with coils and/or vascular plugs. Technical (technical success of establishing TIPS and completely obliterating the DVs) and clinical outcomes (rebleeding rate and survival) were evaluated. Five patients with liver cirrhosis presenting with bleeding DVs were included in the study with all eventually (and coincidentally) receiving TIPS and transvenous obliteration. Two of the five patients underwent concomitant TIPS and transvenous obliteration in the same procedural setting. However, three patients underwent transvenous obliteration due to bleeding despite a patent TIPS that had been previously placed. The average time from TIPS placement to transvenous obliteration was 125 days (range: 3-324 days). After having both procedures, there was no rebleeding in the patients during a mean follow-up period of 22 months (6-50 months). Coils and/or metallic vascular plugs were used to augment the sclerosant obliteration in four of five patients. The combination of TIPS decompression and foam sclerosant transvenous obliteration appears to be effective in preventing rebleeding in this limited case series and compares favorably with the existing evidence for either approach [TIPS or balloon-occluded retrograde transvenous obliteration (BRTO)] alone.
Mori, Genki; Nonaka, Satoru; Oda, Ichiro; Abe, Seiichiro; Suzuki, Haruhisa; Yoshinaga, Shigetaka; Nakajima, Takeshi; Saito, Yutaka
2015-01-01
Background and study aims: Endoscopic submucosal dissection (ESD) using insulation-tipped knives (IT knives) to treat gastric lesions located on the greater curvature of the gastric body remains technically challenging because of the associated bleeding, control of which can be difficult and time consuming. To eliminate these difficulties, we developed a novel strategy which we have called the “near-side approach method” and assessed its utility. Patients and methods: We reviewed patients who underwent ESD for solitary early gastric cancer located on the greater curvature of the gastric body from January 2003 to September 2014. The technical results of ESD were compared between the group treated with the novel near-side approach method and the group treated with the conventional method. Results: This study included 238 patients with 238 lesions, 118 of which were removed using the near-side approach method and 120 of which were removed using the conventional method. The median procedure time was 92 minutes for the near-side approach method and 120 minutes for the conventional method. The procedure time was significantly shorter in the near-side approach method arm. Although, the procedure time required by an experienced endoscopist was not significantly different between the two groups (100 vs. 110 minutes), the near-side approach group showed significantly shorter procedure time for a less-experienced endoscopist (90 vs. 120 minutes). Conclusions: The near-side approach method appears to require less time to complete gastric ESD than the conventional method using IT knives for technically challenging lesions located on the greater curvature of the gastric body, especially if the procedure is performed by less-experienced endoscopists. PMID:26528496
Syed, Mubin I; Karsan, Hetal; Ferral, Hector; Shaikh, Azim; Waheed, Uzma; Akhter, Talal; Gabbard, Alan; Morar, Kamal; Tyrrell, Robert
2012-02-27
To present a dedicated series of transjugular intrahepatic porto-systemic shunts (TIPS) in the elderly since data is sparse on this population group. A retrospective review was performed of patients at least 65 years of age who underwent TIPS at our institutions between 1997 and 2010. Twenty-five patients were referred for TIPS. We deemed that 2 patients were not considered appropriate candidates due to their markedly advanced liver disease. Of the 23 patients suitable for TIPS, the indications for TIPS placement was portal hypertension complicated by refractory ascites alone (n = 9), hepatic hydrothorax alone (n = 2), refractory ascites and hydrothorax (n = 1), gastrointestinal bleeding alone (n = 8), gastrointestinal bleeding and ascites (n = 3). Of these 23 attempted TIPS procedure patients, 21 patients had technically successful TIPS procedures. A total of 29 out of 32 TIPS procedures including revisions were successful in 21 patients with a mean age of 72.1 years (range 65-82 years). Three of the procedures were unsuccessful attempts at TIPS and 8 procedures were successful revisions of our existing TIPS. Sixteen of 21 patients who underwent successful TIPS (excluding 5 patients lost to follow-up) were followed for a mean of 14.7 mo. Ascites and/or hydrothorax was controlled following technically successful procedures in 12 of 13 patients. Bleeding was controlled following technically successful procedures in 10 out of 11 patients. We have demonstrated that TIPS is an effective procedure to control refractory complications of portal hypertension in elderly patients.
Technical tips for collagenase injection treatment for Dupuytren contracture.
Meals, Roy A; Hentz, Vincent R
2014-06-01
We describe technical tips for injecting collagenase into Dupuytren cords based on experience acquired during the prerelease Food and Drug Administration clinical trials and with subsequent clinical practice. These tips include techniques for extracting the reconstituted enzyme efficiently from the vial, injecting the cord(s) with increased safety to the tendons, and anesthetizing the hand before manipulation. The tips are intended to supplement but by no means replace the manufacturer's prescribing information and training video. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Syed, Mubin I; Karsan, Hetal; Ferral, Hector; Shaikh, Azim; Waheed, Uzma; Akhter, Talal; Gabbard, Alan; Morar, Kamal; Tyrrell, Robert
2012-01-01
AIM: To present a dedicated series of transjugular intrahepatic porto-systemic shunts (TIPS) in the elderly since data is sparse on this population group. METHODS: A retrospective review was performed of patients at least 65 years of age who underwent TIPS at our institutions between 1997 and 2010. Twenty-five patients were referred for TIPS. We deemed that 2 patients were not considered appropriate candidates due to their markedly advanced liver disease. Of the 23 patients suitable for TIPS, the indications for TIPS placement was portal hypertension complicated by refractory ascites alone (n = 9), hepatic hydrothorax alone (n = 2), refractory ascites and hydrothorax (n = 1), gastrointestinal bleeding alone (n = 8), gastrointestinal bleeding and ascites (n = 3). RESULTS: Of these 23 attempted TIPS procedure patients, 21 patients had technically successful TIPS procedures. A total of 29 out of 32 TIPS procedures including revisions were successful in 21 patients with a mean age of 72.1 years (range 65-82 years). Three of the procedures were unsuccessful attempts at TIPS and 8 procedures were successful revisions of our existing TIPS. Sixteen of 21 patients who underwent successful TIPS (excluding 5 patients lost to follow-up) were followed for a mean of 14.7 mo. Ascites and/or hydrothorax was controlled following technically successful procedures in 12 of 13 patients. Bleeding was controlled following technically successful procedures in 10 out of 11 patients. CONCLUSION: We have demonstrated that TIPS is an effective procedure to control refractory complications of portal hypertension in elderly patients. PMID:22400084
Alar setback technique: a controlled method of nasal tip deprojection.
Foda, H M
2001-11-01
To describe an alar cartilage-modifying technique aimed at decreasing nasal tip projection in cases with overdeveloped alar cartilages and to compare it with other deprojection techniques used to correct such deformity. Selected case series. University and private practice settings in Alexandria, Egypt. Twenty patients presenting for rhinoplasty who had overprojected nasal tips primarily due to overdeveloped alar cartilages. All cases were primary cases except for one patient, who had undergone 2 previous rhinoplasties. An external rhinoplasty approach was used to set back the alar cartilages by shortening their medial and lateral crura. The choice of performing a high or low setback depended on the preexisting lobule-to-columella ratio. Following the setback, the alar cartilages were reconstructed in a fashion that increased the strength and stability of the tip complex. Subjective evaluation included clinical examination, analysis of preoperative and postoperative photographs, and patient satisfaction. Objective evaluation of nasal tip projection, using the Goode ratio and the nasofacial angle, was performed preoperatively and repeated at least 6 months postoperatively. A low setback was performed in 16 cases (80%) and a high setback in 4 (20%). The mean follow-up period was 18 months (range, 6-36 months). The technique effectively deprojected the nasal tip as evidenced by the considerable postoperative decrease in values of the Goode ratio and the nasofacial angle. No complications were encountered and no revision surgical procedures were required. The alar setback technique has many advantages; it results in precise predictable amounts of deprojection, controls the degree of tip rotation, preserves the natural contour of the nasal tip, respects the tip support mechanisms, increases the strength and stability of nasal tip complex, preserves or restores the normal lobule-to-columella proportion, and does not lead to alar flaring. However, the technique requires an external rhinoplasty approach and fine technical precision.
Tips on Developing Technical Training Partnerships.
ERIC Educational Resources Information Center
Just, David A.; And Others
This paper begins by presenting tips on developing technical training partnerships from the perspective of the local director of the Ohio Industrial Training Program. This section indicates that every linkage needs a catalyst and that the role of the Ohio Industrial Training Program is to be such a catalyst. The issues and concerns of which the…
Wan, Yue-Meng; Li, Yu-Hua; Xu, Ying; Wu, Hua-Mei; Li, Ying-Chun; Wu, Xi-Nan; Yang, Jin-Hui
2018-01-16
Transjugular intrahepatic portosystemic shunt (TIPS) is an established method for portal hypertension. This study was to investigate the long-term safety, technical success, and patency of TIPS, and to determine the risk factors and clinical impacts of shunt dysfunction. A total of 154 consecutive patients undergoing embolotherapy of gastric coronary vein and/or short gastric vein and TIPS creation were prospectively studied. Follow-up data included technical success, patency and revision of TIPS, and overall survival of patients. During the study, the primary and secondary technical success rates were 98.7% and 100%, respectively. Sixty-three patients developed shunt dysfunction, 30 with shunt stenosis and 33 with shunt occlusion. The cumulative 60-month primary, primary assisted, and secondary patency rates were 19.6%, 43.0%, and 93.4%, respectively. The cumulative 60-month overall survival rates were similar between the TIPS dysfunction group and the TIPS non-dysfunction group (68.6% vs. 58.6%, P = .096). Baseline portal vein thrombosis (P < .001), use of bare stents (P = .018), and portal pressure gradient (PPG) (P = .020) were independent predictors for shunt dysfunction, hepatocellular carcinoma (P < .001), and ascites (P = .003) for overall survival. The accuracy of PPG for shunt dysfunction was statistically significant (P < .001), and a cutoff value of 8.5 had 77.8% sensitivity and 64.8% specificity. The long-term safety, technical success, and patency of TIPS were good; baseline portal vein thrombosis, use of bare stents, and PPG were significantly associated with shunt dysfunction; shunt dysfunction has little impact on patients' long-term survival because of high secondary patency rates. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Technical tips: Electrode application and preventing skin breakdown techniques.
Berlin, Fira; Carlile, Jennifer A; de Burgo, Maria I; Rochon, Adrienne; Wagner, Esperanza E; Sellers, Martha C; Worrell, Amanda R; Andal, E Lauren C; Woods, Latina R
2011-09-01
The recording electrodes including their precise location, their ability to record during movements that can be intense during a convulsive seizure, and their capability to record for several days without causing skin breakdown are an integral part of long-term EEG recording. Many of the facets of EEG technology have changed dramatically with the introduction of digital EEG. But the electrode and the electrode/skin interface have not had many dramatic changes. The technologist still looks for ways to ensure correct electrode placement, good recording capabilities, and a patient with healthy skin when the electrodes are removed. This Technical Tips features ideas and experiences from several technologists. These technologists express suggestions and opinions which are accepted in Technical Tips.
Rossitto, Cristiano; Gueli Alletti, Salvatore; Costantini, Barbara; Fanfani, Francesco; Scambia, Giovanni
2016-01-01
To highlight the first case of laparoscopic hysterectomy performed with percutaneous instruments (The Percuvance System, Teleflex Incorporated, Wayne, PA). The basis of the system is a <3-mm diameter shaft that, when connected to an introducer tool tip, can be inserted percutaneously through the skin. The introducer tool tip can then be exchanged outside the body for a wide variety of 5-mm interchangeable surgical tool tips. The shaft is sufficiently strong to hold structures, and surgeons can use its interchangeable tool tips to grasp, cut, and manipulate tissue. We used a 3-dimensional high-definition 10-mm flexible tip endoscope (ENDOEYE FLEX 3D, Olympus Winter & IBE GMBH, Hamburg, Germany). Minilaparoscopy is an attractive approach for hysterectomy due to advantages such as reduced morbidities and enhanced cosmesis. However, it has not been popularized because of the lack of suitable instruments and high technical demand. The Percuvance system represents a significant advance in minimally invasive surgery. Catholic University of the Sacred Hearth, Rome, Italy. A 53-year-old, multiparous patient with endometrial endometroid cancer grade 1, Fédération Internationale de Gynécologie et d'Obstétrique stage IA. The patient provided informed consent to use the images and video of the procedure. Institutional review board approval was not required. The patient was hysteroscopically diagnosed with endometrial cancer after removal of an endometrial polyp adnexectomy. Once referred to our center, surgical staging was planned, including total hysterectomy and bilateral adnexectomy. Laparoscopy with 2 lateral percutaneous and 1 soprapubic 3-mm instruments was believed to be feasible to achieve these procedures. The operation was performed successfully with no intraoperative or postoperative complications. Operative time was 80 minutes overall, and blood loss was 50 mL. The pathology report confirmed endometrial endometroid cancer grading 1, Fédération Internationale de Gynécologie et d'Obstétrique stage IA. The patient was discharged on day 1. After 2 months, no late complications or recurrence was detected. Percutaneous total hysterectomy is technically feasible, and the use of this novel device permits surgeons to maintain a standard setting. Further studies are mandatory to define the benefits, advantages, and costs of this novel approach with respect to other minimally invasive approaches. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Surgery for Locally Recurrent Rectal Cancer: Tips, Tricks, and Pitfalls.
Warrier, Satish K; Heriot, Alexander G; Lynch, Andrew Craig
2016-06-01
Rectal cancer can recur locally in up to 10% of the patients who undergo definitive resection for their primary cancer. Surgical salvage is considered appropriate in the curative setting as well as select cases with palliative intent. Disease-free survival following salvage resection is dependent upon achieving an R0 resection margin. A clear understanding of applied surgical anatomy, appropriate preoperative planning, and a multidisciplinary approach to aggressive soft tissue, bony, and vascular resection with appropriate reconstruction is necessary. Technical tips, tricks, and pitfalls that may assist in managing these cancers are discussed and the roles of additional boost radiation and intraoperative radiation therapy in the management of such cancers are also discussed.
Laparoscopic resection of transverse colon cancer at splenic flexure: technical aspects and results.
Okuda, Junji; Yamamoto, Masashi; Tanaka, Keitaro; Masubuchi, Shinsuke; Uchiyama, Kazuhisa
2016-03-01
Laparoscopic resection of transverse colon cancer at splenic flexure is technical demanding and its efficacy remains controversial. The aim of this study was to investigate its technical aspects such as pitfalls and overcoming them, and to demonstrate the short-term and oncologic long-term outcomes. To overcome the difficulty in laparoscopic resection of transverse colon cancer at splenic flexure, we recognized the following technical tips as essential. First of all, we have to precisely identify major vessels variations feeding tumor. Secondary, anatomical dissection of mesocolon through medial approach is indispensible. Third, safe takedown of splenic flexure to fully mobilization of left hemicolon is mandatory. This cohort study analyzed 95 patients with stage II (43) and III (52) underwent resection of transverse colon cancer at splenic flexure. 61 laparoscopic surgeries (LAC) and 34 conventional open surgeries (OC) from December 1996 to December 2009 were evaluated. Short-term and oncologic long-term outcomes were recorded. Operative time was longer in LAC. However, blood loss was less, recovery of bowel function and hospital stay were shorter in LAC. There was no conversion in LAC and no significant difference in the postoperative complications. Regarding oncologic long-term outcomes, there were no significant differences between OC and LAC. Laparoscopic resection of transverse colon cancer at splenic flexure resulted in acceptable short-term and oncologic long-term outcomes. Once technical tips acquired, laparoscopic resection of transverse colon cancer at splenic flexure could be feasible as minimally invasive surgery.
Lauermann, J; Potthoff, A; Mc Cavert, M; Marquardt, S; Vaske, B; Rosenthal, H; von Hahn, T; Wacker, F; Meyer, B C; Rodt, Thomas
2016-04-01
To analyse technical and clinical success of transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and compare a stent and a stentgraft with regard to clinical and technical outcome and associated costs. 170 patients (56 ± 12 years, 32.9% females) treated with TIPS due to portal hypertension were reviewed. 80 patients received a stent (group 1) and 83 a stentgraft (group 2), and seven interventions were unsuccessful. Technical data, periprocedural imaging, follow-up ultrasound and clinical data were analysed with focus on technical success, patency, clinical outcome and group differences. Cost analysis was performed. Portal hypertension was mainly caused by ethyltoxic liver cirrhosis with ascites as dominant symptom (80%). Technical success was 93.5% with mean portosystemic gradient decrease from 16.1 ± 4.8 to 5.1 ± 2.1 mmHg. No significant differences in technical success and portosystemic gradient decrease between the groups were observed. Kaplan-Meier analysis yielded significant differences in primary patency after 14 days, 6 months and 2 years in favour of the stentgraft. Both groups showed good clinical results without significant difference in 1-year survival and hepatic encephalopathy rate. Costs to establish TIPS and to manage 2-year follow-up with constant patency and clinical success were 8876 € (group 1) and 9394 € (group 2). TIPS is a safe and effective procedure to manage portal hypertension. Stent and stentgraft enabled good technical and clinical results with a low complication rate. Primary patency rates are clearly in favour of the stentgraft, whereas the stent was more cost effective with similar clinical results in both groups.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lauermann, J., E-mail: jostlauermann@gmail.com; Potthoff, A.; Mc Cavert, M.
PurposeTo analyse technical and clinical success of transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and compare a stent and a stentgraft with regard to clinical and technical outcome and associated costs.Materials and Methods170 patients (56 ± 12 years, 32.9 % females) treated with TIPS due to portal hypertension were reviewed. 80 patients received a stent (group 1) and 83 a stentgraft (group 2), and seven interventions were unsuccessful. Technical data, periprocedural imaging, follow-up ultrasound and clinical data were analysed with focus on technical success, patency, clinical outcome and group differences. Cost analysis was performed.ResultsPortal hypertension was mainly caused by ethyltoxicmore » liver cirrhosis with ascites as dominant symptom (80 %). Technical success was 93.5 % with mean portosystemic gradient decrease from 16.1 ± 4.8 to 5.1 ± 2.1 mmHg. No significant differences in technical success and portosystemic gradient decrease between the groups were observed. Kaplan–Meier analysis yielded significant differences in primary patency after 14 days, 6 months and 2 years in favour of the stentgraft. Both groups showed good clinical results without significant difference in 1-year survival and hepatic encephalopathy rate. Costs to establish TIPS and to manage 2-year follow-up with constant patency and clinical success were 8876 € (group 1) and 9394 € (group 2).ConclusionTIPS is a safe and effective procedure to manage portal hypertension. Stent and stentgraft enabled good technical and clinical results with a low complication rate. Primary patency rates are clearly in favour of the stentgraft, whereas the stent was more cost effective with similar clinical results in both groups.« less
Cui, Jianlei; Yang, Lijun; Wang, Yang; Mei, Xuesong; Wang, Wenjun; Hou, Chaojian
2015-02-04
With the development of nanoscience and nanotechnology for the bottom-up nanofabrication of nanostructures formed from polystyrene nanoparticles, joining technology is an essential step in the manufacturing and assembly of nanodevices and nanostructures in order to provide mechanical integration and connection. To study the nanospot welding of polystyrene nanoparticles, we propose a new nanospot-soldering method using the near-field enhancement effect of a metallic atomic force microscope (AFM) probe tip that is irradiated by an optical fiber probe laser. On the basis of our theoretical analysis of the near-field enhancement effect, we set up an experimental system for nanospot soldering; this approach is carried out by using an optical fiber probe laser to irradiate the AFM probe tip to sinter the nanoparticles, providing a promising technical approach for the application of nanosoldering in nanoscience and nanotechnology.
Lee, Moses; Guyton, Gregory P; Zahoor, Talal; Schon, Lew C
2016-01-01
As a standard open approach, the lateral oblique incision has been widely used for calcaneal displacement osteotomy. However, just as with other orthopedic procedures that use an open approach, complications, including wound healing problems and neurovascular injury in the heel, have been reported. To help avoid these limitations, a percutaneous technique using a Shannon burr for calcaneal displacement osteotomy was introduced. However, relying on a free-hand technique without direct visualization at the osteotomy site has been a major obstacle for this technique. To address this problem, we developed a technical tip using a reference Kirschner wire. A reference Kirschner wire technique provides a reliable and accurate guide for minimally invasive calcaneal displacement osteotomy. Also, the technique should be easy to learn for surgeons new to the procedure. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Andring, Brice; Kalva, Sanjeeva P; Sutphin, Patrick; Srinivasa, Rajiv; Anene, Alvin; Burrell, Marc; Xi, Yin; Pillai, Anil K
2015-07-14
To assess the effect of technical parameters on outcomes of transjugular intrahepatic portosystemic shunt (TIPS) created using a stent graft. The medical records of 68 patients who underwent TIPS placement with a stent graft from 2008 to 2014 were reviewed by two radiologists blinded to the patient outcomes. Digital Subtraction Angiographic images with a measuring catheter in two orthogonal planes was used to determine the TIPS stent-to-inferior vena cava distance (SIVCD), hepatic vein to parenchymal tract angle (HVTA), portal vein to parenchymal tract angle (PVTA), and the accessed portal vein. The length and diameter of the TIPS stent and the use of concurrent variceal embolization were recorded by review of the patient's procedure note. Data on re-intervention within 30 d of TIPS placement, recurrence of symptoms, and survival were collected through the patient's chart. Cox proportional regression analysis was performed to assess the effect of these technical parameters on primary patency of TIPS, time to recurrence of symptoms, and all-cause mortality. There was no significant association between the SIVCD and primary patency (P = 0.23), time to recurrence of symptoms (P = 0.83), or all-cause mortality (P = 0.18). The 3, 6, and 12-mo primary patency rates for a SIVCD ≥ 1.5 cm were 82.4%, 64.7%, and 50.3% compared to 89.3%, 83.8%, and 60.6% for a SIVCD of < 1.5 cm (P = 0.29). The median time to stenosis for a SIVCD of ≥ 1.5 cm was 19.1 mo vs 15.1 mo for a SIVCD of < 1.5 cm (P = 0.48). There was no significant association between the following factors and primary patency: HVTA (P = 0.99), PVTA (P = 0.65), accessed portal vein (P = 0.35), TIPS stent diameter (P = 0.93), TIPS stent length (P = 0.48), concurrent variceal embolization (P = 0.13) and reinterventions within 30 d (P = 0.24). Furthermore, there was no correlation between these technical parameters and time to recurrence of symptoms or all-cause mortality. Recurrence of symptoms was associated with stent graft stenosis (P = 0.03). TIPS stent-to-caval distance and other parameters have no significant effect on primary patency, time to recurrence of symptoms, or all-cause mortality following TIPS with a stent-graft.
Orthognathic Surgery and Rhinoplasty to Address Nasomaxillary Hypoplasia.
Veeramani, Anamika; Sawh, Raj; Steinbacher, Derek M
2017-11-01
The treatment of nasomaxillary hypoplasia is challenging. The phenotype of Binder "syndrome" includes the following: midfacial hypoplasia, class III malocclusion, small or absent anterior nasal spine, flattened nose, horizontal nostrils, short columella, acute nasolabial angle, and a flat frontonasal angle. A staged approach is used, with orthognathic surgery to achieve vertical maxillary length and sagittal advancement, followed by rhinoplasty aimed to increase nasal tip projection, rotation, and columellar length. This article details the diagnosis and treatment of nasomaxillary hypoplasia, demonstrating the senior author's (D.M.S.) preferred approach and technical steps. Therapeutic, V.
Retrieval of the 1964 Laser Literature Using MIT's Project Tip.
ERIC Educational Resources Information Center
Keenan, Stella; Terry, Edward
Reported are the performance characteristics of the Massachusetts Institute of Technology Technical Information Program (TIP) system based on a study involving three search strategies in retrieval o f laser articles published in 1964. The TIP system provides access to (1) title, (2) author(s), (3) bibliographic references, and (4) literature…
Safe surgical technique for associated acetabular fractures
2013-01-01
Associated acetabular fractures are challenging injuries to manage. The complex surgical approaches and the technical difficulty in achieving anatomical reduction imply that the learning curve to achieve high-quality care of patients with such challenging injuries is extremely steep. This first article in the Journal’s “Safe Surgical Technique” section presents the standard surgical care, in conjunction with intraoperative tips and tricks, for the safe management of all subgroups of associated acetabular fractures. PMID:23414782
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bahramipour, Phillip F.; Festa, Steven; Biswal, Rajiv
Though polycystic liver disease (PCLD) has historically been considered a contraindication to TIPS, we present a case where technically successful shunt creation was achieved without the need for modification of the standard TIPS procedure, as was required in a previous report.
Dissatisfaction with Nasal Tip Shape: Secondary Tip Maneuvers.
Moyer, Jeffrey S
2018-06-01
Dissatisfaction with the appearance of the nasal tip is a common compliant in patients seeking revision surgery after rhinoplasty. Revision rhinoplasty is more technically difficult and unpredictable given the frequent presence of scar contracture, impaired skin envelope quality, and missing alar cartilage. This article describes some of the more common causes for tip revision surgery and techniques to address these abnormalities. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
NASA Astrophysics Data System (ADS)
Canzian, Blaise; Barentine, J.; Hull, T.
2012-01-01
L-3 Integrated Optical Systems (IOS) Division has been selected by the National Solar Observatory (NSO) to make the Top End Optical Assembly (TEOA) for the 4-meter Advanced Technology Solar Telescope (ATST) to operate at Haleakala, Maui. ATST will perform to a very high optical performance level in a difficult thermal environment. The TEOA, containing the 0.65-meter silicon carbide secondary mirror and support, mirror thermal management system, mirror positioning and fast tip-tilt system, field stop with thermally managed heat dump, thermally managed Lyot stop, safety interlock and control system, and support frame, operates in the "hot spot” at the prime focus of the ATST and so presents special challenges. In this paper, we will describe the L-3 IOS technical approach to meet these challenges, including subsystems for opto-mechanical positioning, rejected and stray light control, wavefront tip-tilt compensation, and thermal management. Key words: ATST, TEOA, L-3 IOS, thermal management, silicon carbide (SiC) mirrors, hexapods, solar astronomy
Ectopic Varices in the Gastrointestinal Tract: Short- and Long-Term Outcomes of Percutaneous Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Macedo, Thanila A., E-mail: macedo.thanila@mayo.edu; Andrews, James C.; Kamath, Patrick S.
2005-04-15
To evaluate the results of percutaneous management of ectopic varices, a retrospective review was carried out of 14 patients (9 men, 5 women; mean age 58 years) who between 1992 and 2001 underwent interventional radiological techniques for management of bleeding ectopic varices. A history of prior abdominal surgery was present in 12 of 14 patients. The interval between the surgery and percutaneous intervention ranged from 2 to 38 years. Transhepatic portal venography confirmed ectopic varices to be the source of portal hypertension-related gastrointestinal bleeding. Embolization of the ectopic varices was performed by a transhepatic approach with coil embolization of themore » veins draining into the ectopic varices. Transjugular intrahepatic portosystemic shunt (TIPS) was performed in the standard fashion. Eighteen procedures (12 primary coil embolizations, 1 primary TIPS, 2 re-embolizations, 3 secondary TIPS) were performed in 13 patients. One patient was not a candidate for percutaneous treatment. All interventions but one (re-embolization) were technically successful. In 2 of 18 interventions, re-bleeding occurred within 72 hr (both embolization patients). Recurrent bleeding (23 days to 27 months after initial intervention) was identified in 9 procedures (8 coil embolizations, 1 TIPS due to biliary fistula). One patient had TIPS revision because of ultrasound surveillance findings. New encephalopathy developed in 2 of 4 TIPS patients. Percutaneous coil embolization is a simple and safe treatment for bleeding ectopic varices; however, recurrent bleeding is frequent and reintervention often required. TIPS can offer good control of bleeding at the expense of a more complex procedure and associated risk of encephalopathy.« less
Editing Tips for Technical Publications in the Joint Nuclear Weapons Publication System (JNWPS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
ALLEN, TARA S.
2002-12-01
These editing tips contain helpful suggestions to assist writers who are writing, editing, and publishing technical publications in the JNWPS. The suggestions clarify some of the most common writing problems and requirements of two publications used in the JNWPS: ''DOE-DTRA TP 1-1, Joint Nuclear Weapons Publications System Operating Procedures, Specifications, and Standards, and United States Government Printing Office Style Manual''. Topics include requirements for abbreviations, formats for drafts, layouts of illustrations and tables, appropriate wording for interim changes, guidance for creating a list of effective pages, how to insert and delete pages and paragraphs, referencing other technical publications, use ofmore » revision bars, requirements for safety precautions, use of hyphens, and how to place warnings, cautions, and notes. Also included are a writer's checklist, samples of draft title pages, and a section of helpful tips for the writers who use the department's desktop publishing software program, Adobe{reg_sign} FrameMaker{reg_sign}.« less
Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.
Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G
2013-04-01
This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.
Technical refinements to improve outcomes following distal hypospadias repair.
Lacy, John M; Hendrix, Lauren N; Bole, Raevti; Habib, Enmar; Wootton, Cole W; Ziada, Ali M
2016-02-01
Hypospadias complications, most notably meatal stenosis, are commonly reported to occur after tubularized incised plate (TIP) hypospadias repair. We focus on a point of technique in TIP repair and its effect on outcome of this possible complication, as well as other commonly reported complications. Meatal stenosis after TIP can be avoided if the urethra and overlying glans are dissected and sutured separately with no attempt at cross suturing whether the urethra ends below, behind, or above the glans sutures. This hypothesis was evaluated by a prospective data collection before and after implementation to evaluate the effect of a technical refinement on rates of meatal stenosis in TIP hypospadias repair. All cases of coronal to midpenile hypospadias repair during two periods were included in our study. Group 1 included 140 consecutive patients over a 30 month period. Group 2 included 122 consecutive patients over a 36 month period during which the above mentioned technical changes were implemented by all participating pediatric urologists. Rates of complications between the two groups were compared with special emphasis on meatal stenosis. Median follow up for both groups was > 1 year. Overall complication rate in Group 1 was 31.5% compared to 9.8% in Group 2. Meatal stenosis was significantly reduced from 13 patients (9.3%) in Group 1 to 2 patients (1.6%) in Group 2, p = 0.008. The technical refinements described resulted in reduction of complication rates and a decrease in incidence of meatal stenosis.
Going Online: Helping Technical Communicators Help Translators.
ERIC Educational Resources Information Center
Flint, Patricia; Lord van Slyke, Melanie; Starke-Meyerring, Doreen; Thompson, Aimee
1999-01-01
Explains why technical communicators should help translators. Offers tips for creating "translation-friendly" documentation. Describes the research and design process used by the authors to create an online tutorial that provides technical communicators at a medical technology company the information they need to help them write and…
ERIC Educational Resources Information Center
Kennedy, Patrick M.
2004-01-01
The main reason engineers, technicians, and programmers write poor technical documents is because they have had little training or experience in that area. This article addresses some of the basics that students can use to master technical writing tasks. The article covers the most common problems writers make and offers suggestions for improving…
Materials for advanced turbine engines. Volume 1: Advanced blade tip seal system
NASA Technical Reports Server (NTRS)
Zelahy, J. W.; Fairbanks, N. P.
1982-01-01
Project 3, the subject of this technical report, was structured toward the successful engine demonstration of an improved-efficiency, long-life, tip-seal system for turbine blades. The advanced tip-seal system was designed to maintain close operating clearances between turbine blade tips and turbine shrouds and, at the same time, be resistant to environmental effects including high-temperature oxidation, hot corrosion, and thermal cycling. The turbine blade tip comprised an environmentally resistant, activated-diffussion-bonded, monocrystal superalloy combined with a thin layer of aluminium oxide abrasive particles entrapped in an electroplated NiCr matrix. The project established the tip design and joint location, characterized the single-crystal tip alloy and abrasive tip treatment, and established the manufacturing and quality-control plans required to fully process the blades. A total of 171 blades were fully manufactured, and 100 were endurance and performance engine-tested.
Application of da Vinci(®) Robot in simple or radical hysterectomy: Tips and tricks.
Iavazzo, Christos; Gkegkes, Ioannis D
2016-01-01
The first robotic simple hysterectomy was performed more than 10 years ago. These days, robotic-assisted hysterectomy is accepted as an alternative surgical approach and is applied both in benign and malignant surgical entities. The two important points that should be taken into account to optimize postoperative outcomes in the early period of a surgeon's training are how to achieve optimal oncological and functional results. Overcoming any technical challenge, as with any innovative surgical method, leads to an improved surgical operation timewise as well as for patients' safety. The standardization of the technique and recognition of critical anatomical landmarks are essential for optimal oncological and clinical outcomes on both simple and radical robotic-assisted hysterectomy. Based on our experience, our intention is to present user-friendly tips and tricks to optimize the application of a da Vinci® robot in simple or radical hysterectomies.
Radosevich, P M; LaBerge, J M; Gordon, R L
1994-01-01
Transjugular intrahepatic portosystemic shunt (TIPS) is an exciting new method for treating complications of cirrhosis. Technical advances have allowed TIPS to be widely applied in the treatment of variceal bleeding. This article presents and discusses the results of recent experiences in TIPS placement. TIPS can be successfully placed in almost all patients. The complication rate of the procedure is low. TIPS is an effective means of controlling variceal bleeding and is especially useful for controlling bleeding in patients awaiting liver transplantation. It may also have a role in the treatment of ascites and other conditions related to portal hypertension. The most important issue facing TIPS is the long-term patency of the shunt. Potential solutions to the problem of long-term shunt patency are discussed.
Alamri, A; Hyodo, A; Suzuki, K; Tanaka, Y; Uchida, T; Takano, I; Kowata, K; Iwatate, K; Suzuki, R
2012-11-01
To date, the "monorail snare technique" for the retrieval of entombed microcatheter tips during Onyx(TM) (ev3, Irvine, CA) embolisation of brain arteriovenous malformations (BAVM) has not been described. We report our experiences and some technical aspects in using this technique for the retrieval of entombed Marathon(TM) microcatheter (ev3, Plymouth, MN) tips during Onyx embolisation of BAVM treatment. Onyx was used in the embolisation of 11 patients using 25 feeders over 14 sessions. The 'monorail snare technique' was employed for 14 feeders. Each time, an Amplatz 4 mm Gooseneck Microsnare(TM) (ev3, Plymouth, MN) was loaded into an Excelsior 1018(TM) microcatheter (Boston Scientific, Natick, MA). The Marathon microcatheter was cut just distal to the hub, and the Amplatz/Excelsior combination was introduced along the length of the Marathon microcatheter towards its distal end, as far as possible. The embedded catheter was ensnared and both catheters were pulled free. Microcatheter tip removal was successful in all cases, except for one microcatheter tip becoming detached and needing no further intervention. There were no complications as a direct result of the snare technique. The monorail snare technique is a safe and easy technique for retrieving Onyx-encased microcatheter tips in the treatment of BAVM.
Pereira, Keith; Baker, Reginald; Salsamendi, Jason; Doshi, Mehul; Kably, Issam; Bhatia, Shivank
2016-05-01
Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPS function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.
Advanced and innovative wind energy concept development: Dynamic inducer system, executive summary
NASA Astrophysics Data System (ADS)
Lissaman, P. B. S.; Zalay, A. D.; Hibbs, B. H.
1981-05-01
Concepts to improve the technical and economic performance of wind energy conversion systems (WECS) were examined. One technique for improving the cost-effectiveness of WECS is the use of tip vanes. Tip vanes are small airfoils attached approximately at right angles to the rotor tips with their span oriented approximately parallel to the local freestream. The performance benefits of the dynamic inducer tip vane system were demonstrated Tow-tests conducted on a three-bladed, 3.6-meter diameter rotor show that a dynamic inducer can achieve a power coefficient of 0.5, which exceeds that of a plain rotor by about 35%.
Pippi Salle, J L; Sayed, S; Salle, A; Bagli, D; Farhat, W; Koyle, M; Lorenzo, A J
2016-02-01
The optimal treatment of proximal hypospadias remains controversial. Several techniques have been described, but the best approach remains unsettled. To evaluate and compare the complication rates of proximal hypospadias with and without ventral curvature (VC), according to three different surgical techniques: tubularized incised plate (TIP) uretroplasty, dorsal inlay graft TIP (DIG), and staged preputial repair (SR). It was hypothesized that SR performs better than TIP and DIG for proximal hypospadias. Single-center, retrospective chart review of all patients with primary proximal hypospadias reconstructed between 2003 and 2013. The DIG was selectively employed in cases with narrow urethral plate (UP) and deficient spongiosum. Extensive urethral plate (UP) mobilization (UPM), dorsal plication (DP) and/or deep transverse incisions of tunica albuginea (DTITA) were selectively performed when attempting to spare transecting the UP. Division of UP and SR was favored in cases with severe VC (>50°), which was often concurrently managed with DTITA if intrinsic curvature was present. For SR, tubularization of the graft was performed 6 months later. A total of 140 patients were included. Tubularized incised plate (TIP), DIG, and SR techniques were performed in 57, 23, and 60 patients, respectively. The TIP and DIG techniques achieved similar success rates, although DIG was performed in cases of narrow and spongiosum-deficient plates. Reoperation rates with TIP and DIG techniques was 52.6% and 52.1% (NS). Urethro-cutaneous fistulas were seen in 31.5% and 13% of TIP and DIG techniques, respectively. Staged repair accomplished better results than both TIP and DIG techniques, despite being performed in the most unfavorable cases (reoperation rate 28%). After technical modifications, the DIG technique achieved similar outcomes of SR. Proximal hypospadias remains challenging, regardless of the technique utilized for its repair. Urethro-cutaneous fistulas were more commonly seen after long TIP repairs. Approximately half of the patients undergoing long TIP and DIG procedures needed re-intervention, although the percentage decreased significantly with late modifications in the DIG group. Recurrence of VC after TIP and DIG techniques seemed to be a significant and under-reported complication. Staged repairs, despite being performed for the most severe cases, resulted in overall better outcomes. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
A novel technique for micro-hole forming on skull with the assistance of ultrasonic vibration.
Li, Zhe; Yang, Daoguo; Hao, Weidong; Wu, Tiecheng; Wu, Song; Li, Xiaoping
2016-04-01
Micro-hole opening on skull is technically challenging and is hard to realize by micro-drilling. Low-stiffness of the drill bit is a serious drawback in micro-drilling. To deal with this problem, a novel ultrasonic vibration assisted micro-hole forming technique has been developed. Tip geometry and vibration amplitude are two key factors affecting the performance of this hole forming technique. To investigate their effects, experiment was carried out with 300μm diameter tools of three different tip geometries at three different vibration amplitudes. Hole forming performance was evaluated by the required thrust force, dimensional accuracy, exit burr and micro-structure of bone tissue around the generated hole. Based on the findings from current study, the 60° conically tipped tool helps generate a micro-hole of better quality at a smaller thrust force, and it is more suitable for hole forming than the 120° conically tipped tool and the blunt tipped tool. As for the vibration amplitude, when a larger amplitude is used, a micro-hole of better quality and higher dimensional accuracy can be formed at a smaller thrust force. Findings from this study would lay a technical foundation for accurately generating a high-quality micro-hole on skull, which enables minimally invasive insertion of a microelectrode into brain for neural activity measuring. Copyright © 2015 Elsevier Ltd. All rights reserved.
Influence of wing tip morphology on vortex dynamics of flapping flight
NASA Astrophysics Data System (ADS)
Krishna, Swathi; Mulleners, Karen
2013-11-01
The mechanism of flapping wing flight provides insects with extraordinary flight capabilities. The uniquely shaped wing tips give insects an edge in flight performance and the interaction between the leading edge vortices and wing tip vortices enhance their propelling efficiencies and manoeuvrability. These are qualities that are sought after in current-day Micro Air Vehicles. A detailed understanding of the vortex dynamics of flapping flight and the influence of the wing tip planform is imperative for technical application. An experimental study is conducted to investigate the effects of different wing tip planforms on the formation, evolution and interaction of vortical structures. We thereby focus on the interaction between the coherent structures evolving from the leading edge and the wing tip during pitching and flapping motions.The spatial and temporal evolution of the three-dimensional flow structures are determined using Scanning (Stereo) Particle Image Velocimetry and an in-depth coherent structure analysis. By comparing the vortex dynamics, the aerodynamic performance of various wing tip planforms are evaluated.
Tsauo, Jiaywei; Luo, Xuefeng; Ye, Linchao; Li, Xiao
2015-06-01
This study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS). 3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate the angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients. Failure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures. Adjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.
Salle, Henri; Cavalcanti Mendes, George de Albuquerque; Gantois, Clément; Lerat, Justine; Aldahak, Nouman; Caire, François
2017-10-01
Surgery of the craniocervical junction (CCJ) and clivus is technically demanding. For many years, we have used the submandibular retropharyngeal approach for surgery of the upper cervical spine, especially hangman fracture. We hypothesized that submandibular gland resection could offer a significant cranial enlargement of the operative field, up to the clivus. Our aim in this work was to assess the feasibility of an endoscope-assisted retropharyngeal approach to the CCJ and clivus. Eight anatomic specimens were used, including 4 silicon-injected specimens. We performed a submandibular retropharyngeal approach with gland resection, and then we exposed the CCJ and clivus. We drilled the C2 vertebral body, odontoid process, C1 anterior arch, and the clivus. We noted 8 anatomic landmarks that were easily identified on each anatomic specimen. These measurements were designed to quantify the exposure of the clivus and CCJ after bone resection. A submandibular approach was feasible in all specimens. The main dimensions of the area of dural exposure after bone drilling were as follows: mean width between C1 lateral masses, 19 mm (range, 17-20 mm); at the tip of the clival window, 18 mm (range, 16-20 mm); distance between the C3 vertebra and the tip of the window within the clivus, 57 mm (range, 55-60 mm). An endoscopic submandibular retropharyngeal approach provides a simple and straightforward access to the CCJ. It also conveniently exposes the clivus. This technique could be added to the techniques used for this difficult surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
He, Fu-Liang; Wang, Lei; Zhao, Hong-Wei; Fan, Zhen-Hua; Zhao, Meng-Fei; Dai, Shan; Yue, Zhen-Dong; Liu, Fu-Quan
2015-02-28
To evaluate the feasibility of transjugular intrahepatic portosystemic shunt (TIPS) for severe jaundice secondary to acute Budd-Chiari syndrome (BCS). From February 2009 to March 2013, 37 patients with severe jaundice secondary to acute BCS were treated. Sixteen patients without hepatic venule, hepatic veins (HV) obstruction underwent percutaneous angioplasty of the inferior vena cava (IVC) and/or HVs. Twenty-one patients with HV occlusion underwent TIPS. Serum bilirubin, liver function, demographic data and operative data of the two groups of patients were analyzed. Twenty-one patients underwent TIPS and the technical success rate was 100%, with no technical complications. Sixteen patients underwent recanalization of the IVC and/or HVs and the technical success rate was 100%. The mean procedure time for TIPS was 84.0±12.11 min and angioplasty was 44.11±5.12 min (P<0.01). The mean portosystemic pressure in the TIPS group decreased significantly from 40.50±4.32 to 16.05±3.50 mmHg (P<0.01). The mean portosystemic pressure gradient decreased significantly from 33.60±2.62 to 7.30±2.21 mmHg (P<0.01). At 8 wk after the procedures, in the TIPS group, total bilirubin (TBIL) decreased significantly from 266.24±122.03 before surgery to 40.11±3.52 μmol/L (P<0.01) and direct bilirubin (DBIL) decreased significantly from 194.22±69.82 μmol/L to 29.82±3.10 μmol/L (P<0.01). In the angioplasty group, bilirubin returned to the normal range, with TBIL decreased significantly from 258.22±72.71 μmol/L to 13.33±3.54 μmol/L (P<0.01) and DBIL from 175.08±39.27 to 4.03±1.74 μmol/L (P<0.01). Liver function improved faster than TBIL. After 2 wk, in the TIPS group, alanine aminotransferase (ALT) decreased significantly from 50.33±40.61 U/L to 28.67±7.02 U/L (P<0.01) and aspartate aminotransferase (AST) from 49.46±34.33 U/L to 26.89±8.68 U/L (P<0.01). In the angioplasty group, ALT decreased significantly from 51.56±27.90 to 14.22±2.59 μmol/L (P<0.01) and AST from 60.66±39.89 μmol/L to 8.18±1.89 μmol/L (P<0.01). After mean follow-up of 12.6 mo, there was no recurrence of jaundice in either group. Severe jaundice is not a contraindication for TIPS in patients with acute BCS and TIPS is appropriate for severe jaundice due to BCS.
Peroral Endoscopic Myotomy in Children: First Experience With a New Triangular Knife.
Nabi, Zaheer; Ramchandani, Mohan; Chavan, Radhika; Tandan, Manu; Kalapala, Rakesh; Darisetty, Santosh; Reddy, Duvuur Nageshwar
2018-01-01
Peroral endoscopic myotomy (POEM) is a novel treatment modality for achalasia cardia. The procedure is technically challenging and time consuming. Recently, a new triangle tip knife (TTJ) has been introduced, which is equipped with water jet facility. In the present study, we analyzed the feasibility, safety, and efficacy of POEM in children with new triangle tip knife. We retrospectively evaluated the data of children (18 years or younger) who underwent POEM using TTJ knife at our institution. All POEM procedures were performed under general anesthesia in an endoscopy suite. Technical feasibility, safety, efficacy, and procedure duration were assessed. Ten children (4 boys, 6 girls) with mean age of 14.2 ± 2.74 (9-18) years, underwent POEM with TTJ knife. The subtypes of achalasia cardia were type I (4), type II (5), and type III (1). Two children had prior treatment with pneumatic balloon dilatation. POEM was performed via anterior route in majority of children (70%). Mean operating time was 47.6 ± 19.74 (30-98) minutes with no significant difference between anterior and posterior approaches to POEM (48.57 ± 24.01 vs 45.3 ± 3.51; P < 0.05). Four gas-related adverse events were encountered including capnoperitoneum and retroperitoneal carbon dioxide in 2 children each. Clinical success was noticed in 9 children with significant reduction in Eckardt score at 1 month after POEM (6.7 ± 1.49 vs 0.3 ± 0.48; P = 0.0001). POEM can be efficiently performed with new triangle knife equipped with water jet technique. Integration of water jet reduces procedure duration and technical difficulty with POEM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsauo, Jiaywei, E-mail: 80732059@qq.com; Luo, Xuefeng, E-mail: luobo-913@126.com; Ye, Linchao, E-mail: linchao.ye@siemens.com
2015-06-15
PurposeThis study was designed to report our results with a modified technique of three-dimensional (3D) path planning software assisted transjugular intrahepatic portosystemic shunt (TIPS).Methods3D path planning software was recently developed to facilitate TIPS creation by using two carbon dioxide portograms acquired at least 20° apart to generate a 3D path for overlay needle guidance. However, one shortcoming is that puncturing along the overlay would be technically impossible if the angle of the liver access set and the angle of the 3D path are not the same. To solve this problem, a prototype 3D path planning software was fitted with a utility to calculate themore » angle of the 3D path. Using this, we modified the angle of the liver access set accordingly during the procedure in ten patients.ResultsFailure for technical reasons occurred in three patients (unsuccessful wedged hepatic venography in two cases, software technical failure in one case). The procedure was successful in the remaining seven patients, and only one needle pass was required to obtain portal vein access in each case. The course of puncture was comparable to the 3D path in all patients. No procedure-related complication occurred following the procedures.ConclusionsAdjusting the angle of the liver access set to match the angle of the 3D path determined by the software appears to be a favorable modification to the technique of 3D path planning software assisted TIPS.« less
Tips for a Successful Job Search. PEPNet Tipsheet
ERIC Educational Resources Information Center
PEPNet-Northeast, 2009
2009-01-01
Looking for a job can be a challenging experience. It helps to have a positive attitude and to be well prepared for every aspect of the job search. This tipsheet uses information from the NTID (National Technical Institute for the Deaf) Center on Employment (NCE) at Rochester Institute of Technology/National Technical Institute for the Deaf and…
Parker, Matthew J; Guha, Neil; Stedman, Brian; Hacking, Nigel; Wright, Mark
2013-01-01
Objective To assess the benefit of trans-jugular intrahepatic porto-systemic shunt (TIPS) placement for refractory ascites. Design A retrospective observational study of all patients undergoing TIPS for refractory ascites in our hospital between 2003 and 2012. Setting Secondary care. Patients Cirrhotic patients with refractory ascites. Main outcome measures We examined direct real-world (National Health Service) health related costs in the year before and after the TIPS procedure took place. Data were collected relating to the need for reintervention and hepatic encephalopathy. Results Data were available for 24 patients who underwent TIPS for refractory ascites (86% of eligible patients). TIPS was technically successful in all cases. Mean number of bed days in the year prior to TIPS was 30.3 and 14.3 in the year following (p=0.005). No patient had ascites at the end of the year after the TIPS with less requirement for paracentesis over the course of the year (p<0.001). Mean reduction in cost was £2759 per patient. TIPS was especially cost-effective in patients requiring between 6 and 12 drains per year with a mean saving of £9204 per patient. Conclusions TIPS is both a clinically effective and economically advantageous therapeutic option for selected patients with refractory ascites. PMID:28839725
Parker, Matthew J; Guha, Neil; Stedman, Brian; Hacking, Nigel; Wright, Mark
2013-07-01
To assess the benefit of trans-jugular intrahepatic porto-systemic shunt (TIPS) placement for refractory ascites. A retrospective observational study of all patients undergoing TIPS for refractory ascites in our hospital between 2003 and 2012. Secondary care. Cirrhotic patients with refractory ascites. We examined direct real-world (National Health Service) health related costs in the year before and after the TIPS procedure took place. Data were collected relating to the need for reintervention and hepatic encephalopathy. Data were available for 24 patients who underwent TIPS for refractory ascites (86% of eligible patients). TIPS was technically successful in all cases. Mean number of bed days in the year prior to TIPS was 30.3 and 14.3 in the year following (p=0.005). No patient had ascites at the end of the year after the TIPS with less requirement for paracentesis over the course of the year (p<0.001). Mean reduction in cost was £2759 per patient. TIPS was especially cost-effective in patients requiring between 6 and 12 drains per year with a mean saving of £9204 per patient. TIPS is both a clinically effective and economically advantageous therapeutic option for selected patients with refractory ascites.
Twelve tips for the effective use of videos in medical education.
Dong, Chaoyan; Goh, Poh Sun
2015-02-01
Videos can promote learning by either complementing classroom activities, or in self-paced online learning modules. Despite the wide availability of online videos in medicine, it can be a challenge for many educators to decide when videos should be used, how to best use videos, and whether to use existing videos or produce their own. We outline 12 tips based on a review of best practices in curriculum design, current research in multimedia learning and our experience in producing and using educational videos. The 12 tips review the advantages of using videos in medical education, present requirements for teachers and students, discuss how to integrate video into a teaching programme, and describe technical requirements when producing one's own videos. The 12 tips can help medical educators use videos more effectively to promote student engagement and learning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, Keith, E-mail: keithjppereira@gmail.com; Baker, Reginald, E-mail: rbaker@med.miami.edu; Salsamendi, Jason
Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPSmore » function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.« less
Jahangiri, Younes; Kerrigan, Timothy; Li, Lei; Prosser, Dominik; Brar, Anantnoor; Righetti, Johnathan; Schenning, Ryan C; Kaufman, John A; Farsad, Khashayar
2017-12-01
To identify risk factors of stent graft thrombosis after transjugular intrahepatic portosystemic shunt (TIPS) creation. Patients who underwent TIPS creation between June 2003 and January 2016 and with follow-up assessing stent graft patency were included (n=174). Baseline comorbidities, liver function, procedural details and follow-up liver function tests were analyzed in association with hazards of thrombosis on follow-up. Competing risk cox regression models were used considering liver transplant after TIPS creation as the competing risk variable. One-, 2- and 5-year primary patency rates were 94.1%, 91.7% and 78.2%, respectively. Patient age [sub-hazard ratio (sHR): 1.13; P=0.001], body mass index (BMI) <30 (sHR: 33.08; P=0.008) and a higher post-TIPS portosystemic pressure gradient (sHR: 1.14; P=0.023) were significantly associated with TIPS thrombosis in multivariate analysis. A higher rate of TIPS thrombosis was observed in those for whom the procedure was clinically unsuccessful (P=0.014). A significant increase in incidence of thrombosis was noted with increasing tertiles of post-TIPS portosystemic gradients (P value for trend=0.017). Older age, lower BMI and higher post-TIPS portosystemic gradients were associated with higher hazards of shunt thrombosis after TIPS creation using stent grafts. Higher rates of shunt thrombosis were seen in patients for whom TIPS creation was clinically unsuccessful. The association between TIPS thrombosis and higher post-TIPS portosystemic gradients may indicate impaired flow through the shunt, a finding which may be technical or anatomic in nature and should be assessed before procedure completion.
Leiterer, Christian; Deckert-Gaudig, Tanja; Singh, Prabha; Wirth, Janina; Deckert, Volker; Fritzsche, Wolfgang
2015-05-01
Tip-enhanced Raman spectroscopy, a combination of Raman spectroscopy and scanning probe microscopy, is a powerful technique to detect the vibrational fingerprint of molecules at the nanometer scale. A metal nanoparticle at the apex of an atomic force microscope tip leads to a large enhancement of the electromagnetic field when illuminated with an appropriate wavelength, resulting in an increased Raman signal. A controlled positioning of individual nanoparticles at the tip would improve the reproducibility of the probes and is quite demanding due to usually serial and labor-intensive approaches. In contrast to commonly used submicron manipulation techniques, dielectrophoresis allows a parallel and scalable production, and provides a novel approach toward reproducible and at the same time affordable tip-enhanced Raman spectroscopy tips. We demonstrate the successful positioning of an individual plasmonic nanoparticle on a commercial atomic force microscope tip by dielectrophoresis followed by experimental proof of the Raman signal enhancing capabilities of such tips. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Technical product bulletin: this dispersant for oil spill cleanups should be applied as droplets. Manufacturer recommends that spray tips on booms be changed into solid tubing for injection of product 3 to 5 feet below water surface.
Bapst, D W; Wright, A M; Matzke, N J; Lloyd, G T
2016-07-01
Dated phylogenies of fossil taxa allow palaeobiologists to estimate the timing of major divergences and placement of extinct lineages, and to test macroevolutionary hypotheses. Recently developed Bayesian 'tip-dating' methods simultaneously infer and date the branching relationships among fossil taxa, and infer putative ancestral relationships. Using a previously published dataset for extinct theropod dinosaurs, we contrast the dated relationships inferred by several tip-dating approaches and evaluate potential downstream effects on phylogenetic comparative methods. We also compare tip-dating analyses to maximum-parsimony trees time-scaled via alternative a posteriori approaches including via the probabilistic cal3 method. Among tip-dating analyses, we find opposing but strongly supported relationships, despite similarity in inferred ancestors. Overall, tip-dating methods infer divergence dates often millions (or tens of millions) of years older than the earliest stratigraphic appearance of that clade. Model-comparison analyses of the pattern of body-size evolution found that the support for evolutionary mode can vary across and between tree samples from cal3 and tip-dating approaches. These differences suggest that model and software choice in dating analyses can have a substantial impact on the dated phylogenies obtained and broader evolutionary inferences. © 2016 The Author(s).
NASA Technical Reports Server (NTRS)
Wisler, D. C.
1981-01-01
The core compressor exit stage study program develops rear stage blading designs that have lower losses in their endwall boundary layer regions. The test data and performance results for the best stage configuration consisting of Rotor-B running with Stator-B are described. The technical approach in this efficiency improvement program utilizes a low speed research compressor. Tests were conducted in two ways: (1) to use four identical stages of blading to obtain test data in a true multistage environment and (2) to use a single stage of blading to compare with the multistage test results. The effects of increased rotor tip clearances and circumferential groove casing treatment are evaluated.
NASA Astrophysics Data System (ADS)
Goldberg, S. Nahum; Gazelle, G. Scott
1998-04-01
Radiofrequency (RF) tumor ablation has been demonstrated as a reliable method for creating thermally induced coagulation necrosis using either a percutaneous approach with image- guidance or direct surgical application of thin electrodes into treated tissues. Early clinical trials with this technology have studied the treatment of hepatic, cerebral, and bony malignancies. The extent of coagulation necrosis induced with conventional monopolar radiofrequency electrodes is dependent on overall energy deposition, the duration of RF application, and RF electrode tip length and gauge. This article will discuss these technical considerations with the goal of defining optimal parameters for RF ablation. Strategies to further increase induced coagulation necrosis including: multiprobe and bipolar arrays, and internally-cooled RF electrodes, with or without pulsed-RF or cluster technique will be presented. The development and laboratory results for many of these radiofrequency techniques, initial clinical results, and potential biophysical limitations to RF induced coagulation, such as perfusion mediated tissue cooling (vascular flow) will likewise be discussed.
Percutaneous Pulmonary Embolism Thrombectomy and Thrombolysis: Technical Tips and Tricks.
Devcic, Zlatko; Kuo, William T
2018-06-01
Catheter-directed therapy (CDT) is now acknowledged as a treatment option for select patients with acute massive or submassive pulmonary embolism (PE), and more patients are being considered for CDT if there is available expertise. Therefore, interventionalists should be aware of the variety of catheter-based treatment options, specific pitfalls to avoid during therapy, and the appropriate treatment endpoints. This article reviews currently available techniques and protocols for treating acute massive and submassive PE, with tips to safely and successfully perform percutaneous PE interventions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Eu Hyun, E-mail: doorihyun6@gmail.com; Oh, Jung Suk; Chun, Ho Jong
PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in.more » hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.« less
Kim, Eu Hyun; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil
2017-03-01
The study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion. From 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port. The monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications. The monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.
Cellular and dendritic growth in a binary melt - A marginal stability approach
NASA Technical Reports Server (NTRS)
Laxmanan, V.
1986-01-01
A simple model for the constrained growth of an array of cells or dendrites in a binary alloy in the presence of an imposed positive temperature gradient in the liquid is proposed, with the dendritic or cell tip radius calculated using the marginal stability criterion of Langer and Muller-Krumbhaar (1977). This approach, an approach adopting the ad hoc assumption of minimum undercooling at the cell or dendrite tip, and an approach based on the stability criterion of Trivedi (1980) all predict tip radii to within 30 percent of each other, and yield a simple relationship between the tip radius and the growth conditions. Good agreement is found between predictions and data obtained in a succinonitrile-acetone system, and under the present experimental conditions, the dendritic tip stability parameter value is found to be twice that obtained previously, possibly due to a transition in morphology from a cellular structure with just a few side branches, to a more fully developed dendritic structure.
NASA Technical Reports Server (NTRS)
Bune, Andris V.; Kaukler, William; Whitaker, Ann (Technical Monitor)
2001-01-01
A Modeling approach to simulate both mesoscale and microscopic forces acting in a typical AFM experiment is presented. A mesoscale level interaction between the cantilever tip and the sample surface is primarily described by the balance of attractive Van der Waals and repulsive forces. Ultimately, the goal is to measure the forces between a particle and the crystal-melt interface. Two modes of AFM operation are considered in this paper - a stationary and a "tapping" one. The continuous mechanics approach to model tip-surface interaction is presented. At microscopic levels, tip contamination and details of tip-surface interaction are modeled using a molecular dynamics approach for the case of polystyrene - succinonitrile contact. Integration of the mesoscale model with a molecular dynamic model is discussed.
Neutron and gamma (density) logging in welded tuff
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, W
This Technical Implementation Procedure (TIP) describes the field operation, and the management of data records pertaining to neutron logging and density logging in welded tuff. This procedure applies to all borehole surveys performed in support of Engineered Barrier System Field Tests (EBSFT), including the Earge Block Tests (LBT) and Initial Engineered Barrier System Field Tests (IEBSFT) - WBS 1.2.3.12.4. The purpose of this TIP is to provide guidelines so that other equally trained and qualified personnel can understand how the work is performed or how to repeat the work if needed. The work will be documented by the use ofmore » Scientific Notebooks (SNs) as discussed in 033-YMP-QP 3.4. The TIP will provide a set of guidelines which the scientists will take into account in conducting the mea- surements. The use of this TIP does not imply that this is repetitive work that does not require profes- sional judgment.« less
Koontz, Nicholas A; Wiggins, Richard H; Stoddard, Gregory J; Shah, Lubdha M
2017-10-01
There is a paucity of evidence-based literature regarding the advantages and disadvantages of the interlaminar approach and needle bevel orientation for performing a lumbar interlaminar epidural steroid injection (ESI). The purpose of this study was to determine if superior versus inferior lamina approach, needle bevel tip orientation, or both may predispose to inadvertent nonepidural penetration during lumbar interlaminar ESI. A prospective study was performed of patients with low back pain with or without radicular pain or neurogenic claudication referred for lumbar interlaminar ESI. Two hundred eleven patients were randomized by interlaminar approach (superior vs inferior) and bevel tip orientation (cranial vs caudal). Lumbar interlaminar ESI was performed by six interventionalists of varying levels of experience using fluoroscopic guidance with curved tip epidural needles, using loss-of-resistance technique and confirmation with contrast opacification. Exact Poisson regression was used to model the study outcome. Two hundred twenty-one lumbar interlaminar ESIs were performed on 211 patients, randomized to a superior (n = 121) or inferior lamina approach (n = 100) and to a cranial (n = 103) or caudal (n = 118) orientation of the bevel tip. Epidural needle placement was confirmed in 96.4% (n = 213) of cases. Nonepidural needle placement was most commonly associated with superior lamina approach and caudal bevel tip orientation, which was marginally significant (adjusted risk ratio, 6.88; 95% CI, 0.93-∞; p = 0.059). Inadvertent nonepidural needle penetration during fluoroscopically guided lumbar interlaminar ESI appears to be affected by approach, with superior lamina approach and caudal bevel tip orientation being the least favorable technique.
Risk factors for stent graft thrombosis after transjugular intrahepatic portosystemic shunt creation
Jahangiri, Younes; Kerrigan, Timothy; Li, Lei; Prosser, Dominik; Brar, Anantnoor; Righetti, Johnathan; Schenning, Ryan C.; Kaufman, John A.
2017-01-01
Background To identify risk factors of stent graft thrombosis after transjugular intrahepatic portosystemic shunt (TIPS) creation. Methods Patients who underwent TIPS creation between June 2003 and January 2016 and with follow-up assessing stent graft patency were included (n=174). Baseline comorbidities, liver function, procedural details and follow-up liver function tests were analyzed in association with hazards of thrombosis on follow-up. Competing risk cox regression models were used considering liver transplant after TIPS creation as the competing risk variable. Results One-, 2- and 5-year primary patency rates were 94.1%, 91.7% and 78.2%, respectively. Patient age [sub-hazard ratio (sHR): 1.13; P=0.001], body mass index (BMI) <30 (sHR: 33.08; P=0.008) and a higher post-TIPS portosystemic pressure gradient (sHR: 1.14; P=0.023) were significantly associated with TIPS thrombosis in multivariate analysis. A higher rate of TIPS thrombosis was observed in those for whom the procedure was clinically unsuccessful (P=0.014). A significant increase in incidence of thrombosis was noted with increasing tertiles of post-TIPS portosystemic gradients (P value for trend=0.017). Conclusions Older age, lower BMI and higher post-TIPS portosystemic gradients were associated with higher hazards of shunt thrombosis after TIPS creation using stent grafts. Higher rates of shunt thrombosis were seen in patients for whom TIPS creation was clinically unsuccessful. The association between TIPS thrombosis and higher post-TIPS portosystemic gradients may indicate impaired flow through the shunt, a finding which may be technical or anatomic in nature and should be assessed before procedure completion. PMID:29399518
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilbao, Jose Ignacio; Quiroga, Jorge; Herrero, Jose Ignacio
Since the insertion of the first TIPS in 1989 much has been learned about this therapeutic procedure. It has an established role for the treatment of some complications of portal hypertension: prevention of recurrent variceal bleeding and rescue of patients with acute uncontrollable variceal bleeding. In addition TIPS is useful for Budd-Chiari syndrome, refractory ascites and hepatorenal syndrome, although its specific role in these indications remains to be definitively established. However, the decrease in sinusoidal blood flow induced by TIPS can lead to the patient developing hepatic encephalopathy and liver failure in some cases. Therefore, TIPS should be used withmore » caution in patients with very poor liver function. From a technical point of view, successful placement of TIPS is achieved in more than 98% of cases by experienced groups. At present, evaluation of TIPS dysfunction based on morphology probably leads to an overdiagnosis of this complication since most of these cases are not associated with clinical manifestations (recurrent bleeding or refractory ascites). The major disadvantage of TIPS remains its poor long-term patency requiring a mandatory surveillance program. The indicator for shunt function/malfunction should be the portosystemic pressure gradient, which is best assessed by intravascular measurements. Shunt obstructions may be prevented or reduced by the use of stent-grafts in the future.« less
NASA Astrophysics Data System (ADS)
Jacobs, Tevis D. B.; Wabiszewski, Graham E.; Goodman, Alexander J.; Carpick, Robert W.
2016-01-01
The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tip has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture's use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingraham, Christopher R., E-mail: cringra@uw.edu; Padia, Siddharth A., E-mail: spadia@uw.edu; Johnson, Guy E., E-mail: gej@uw.edu
Background and AimsComplications of portal hypertension, such as variceal hemorrhage and ascites, are associated with significant increases in both mortality and complications during pregnancy. Transjugular intrahepatic portosystemic shunt (TIPS) is a well-established procedure for treating portal hypertension, but the safety of TIPS during pregnancy is largely unknown. In this series, we review five patients who underwent TIPS placement while pregnant and describe their clinical outcomes.MethodsFive pregnant patients with cirrhosis and portal hypertension underwent elective TIPS for complications of portal hypertension (four for secondary prevention of variceal bleeding and one for refractory ascites). Outcomes measured were recurrent bleeding episodes or needmore » for further paracenteses during pregnancy, estimated radiation dose to the fetus and gestational age at delivery. All patients were followed after delivery to evaluate technical and clinical success of the procedure.ResultsAll five patients survived pregnancy and went on to deliver successfully. When TIPS was performed for secondary prevention of variceal bleeding (n = 4), no patients demonstrated variceal bleeding after TIPS placement. When TIPS was performed for refractory ascites (n = 1), no further paracenteses were required. All patients delivered successfully, albeit prematurely. Average radiation dose estimated to the fetus was 16.3 mGy.ConclusionsThis series suggests that TIPS can be performed in selective pregnant patients with portal hypertension, with little added risk to the mother or fetus.« less
A new algorithm for primary hypospadias repair based on tip urethroplasty.
Sozubir, Selami; Snodgrass, Warren
2003-08-01
Decision making in hypospadias repair potentially can be simplified by tubularized incised plate (TIP) urethroplasty. The authors report management and outcomes in a consecutive series of primary hypospadias repairs in which the intent was to perform TIP. Records of 106 consecutive boys undergoing hypospadias repair by 1 surgeon were reviewed. Position of the meatus, degree and management of curvature, technical details of the urethroplasty, and postoperative complications were recorded. Curvature was noted in 24 (23%) of patients, but could be corrected with preservation of the urethral plate in all but 3. In another boy, the incised plate was thought "unhealthy" for tubularization. The remaining 102 underwent TIP, of whom, 75 had distal and 27 had proximal hypospadias. Complications, primarily fistulas, occurred in 14 (13%) of these patients. The other 4 boys underwent staged repairs that utilized TIP for the glanular urethra at the second operation. The authors found decision making was no longer determined by meatal location as in the past, but by severity of curvature and appearance of the incised urethral plate. Because severe curvature requiring plate transection or an "unhealthy" incised plate are uncommonly encountered, TIP repair can be performed for most hypospadias operations.
Abbou, Jeremy; Anne, Agnès; Demaille, Christophe
2006-11-16
The dynamics of a molecular layer of linear poly(ethylene glycol) (PEG) chains of molecular weight 3400, bearing at one end a ferrocene (Fc) label and thiol end-grafted at a low surface coverage onto a gold substrate, is probed using combined atomic force-electrochemical microscopy (AFM-SECM), at the scale of approximately 100 molecules. Force and current approach curves are simultaneously recorded as a force-sensing microelectrode (tip) is inserted within the approximately 10 nm thick, redox labeled, PEG chain layer. Whereas the force approach curve gives access to the structure of the compressed PEG layer, the tip-current, resulting from tip-to-substrate redox cycling of the Fc head of the chain, is controlled by chain dynamics. The elastic bounded diffusion model, which considers the motion of the Fc head as diffusion in a conformational field, complemented by Monte Carlo (MC) simulations, from which the chain conformation can be derived for any degree of confinement, allows the theoretical tip-current approach curve to be calculated. The experimental current approach curve can then be very satisfyingly reproduced by theory, down to a tip-substrate separation of approximately 2 nm, using only one adjustable parameter characterizing the chain dynamics: the effective diffusion coefficient of the chain head. At closer tip-substrate separations, an unpredicted peak is observed in the experimental current approach curve, which is shown to find its origin in a compression-induced escape of the chain from within the narrowing tip-substrate gap. MC simulations provide quantitative support for lateral chain elongation as the escape mechanism.
Ogura, Takeshi; Takagi, Wataru; Kurisu, Yoshitaka; Higuchi, Kazuhide
2016-10-01
Endoscopic retrograde cholangiopancreatography (ERCP) is the gold-standard modality for diagnosis and therapy of bilio-pancreatic disease. In particular, peroral cholangiography (POCS) is a useful modality not only for diagnosing biliary disease, but also for therapeutic procedures such as electrohydraulic lithotripsy. The SPY-DS single-operator cholangioscope has recently become available, and offers favorable visualization, a wide view, suction function and a larger accessory working channel. However, if the duodenoscope cannot be advanced into the ampulla of Vater for reasons such as surgical anatomy, POCS cannot be performed. On the other hand, percutaneous transhepatic cholangiodrainage (PTCD) has been developed as an alternative endoscopic ultrasound-guided approach to the biliary tract. Peroral transluminal cholangioscopy (PTLC) using SPY-DS is a novel approach. Because transluminal interventional procedures under endoscopic ultrasound guidance have recently been developed, our technique may have clinical impact for selected cases. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Berens, Angelique M; Harbison, Richard Alex; Li, Yangming; Bly, Randall A; Aghdasi, Nava; Ferreira, Manuel; Hannaford, Blake; Moe, Kris S
2017-08-01
To develop a method to measure intraoperative surgical instrument motion. This model will be applicable to the study of surgical instrument kinematics including surgical training, skill verification, and the development of surgical warning systems that detect aberrant instrument motion that may result in patient injury. We developed an algorithm to automate derivation of surgical instrument kinematics in an endoscopic endonasal skull base surgery model. Surgical instrument motion was recorded during a cadaveric endoscopic transnasal approach to the pituitary using a navigation system modified to record intraoperative time-stamped Euclidian coordinates and Euler angles. Microdebrider tip coordinates and angles were referenced to the cadaver's preoperative computed tomography scan allowing us to assess surgical instrument kinematics over time. A representative cadaveric endoscopic endonasal approach to the pituitary was performed to demonstrate feasibility of our algorithm for deriving surgical instrument kinematics. Technical feasibility of automatically measuring intraoperative surgical instrument motion and deriving kinematics measurements was demonstrated using standard navigation equipment.
The view from the tip of the iceberg.
Josephs, L
1997-01-01
In recent years there has been a growing interest in refining the technique of ego defense analysis. All of these approaches share in common an attempt to work closely with the patient's free associations, to interpret at a level that is accessible to the patient's consciously observing ego, and to avoid bypassing the analysis of the patient's most surface-level resistances in an effort to understand unconscious conflict. These innovations reflect a commendable effort to work in a way that is rigorously empirical, that respects the patient's autonomy, and that minimizes the pressure of the analyst's transferential authority in the patient's acceptance of the analyst's interpretations. Despite the undeniable value of these technical innovations, such approaches to ego defense analysis may inadvertently result in certain overemphases in technique that may unnecessarily constrain the analytic process. They may result in a sort of obsessive tunnel vision that is overly focused on small details to the exclusion of the larger picture. An approach that counterbalances the microscopic and the macroscopic analysis of ego defense is recommended.
DIY Solar Market Analysis STAT Webinars | State, Local, and Tribal
do they help policymakers? Solar Resource and Technical Potential: Finding, using, and making maps for decision makers PVWatts: New tips and tricks for the latest update Community Solar Scenario Tool
Technical Tips: Performing EEGs and Polysomnograms on Children with Neurodevelopmental Disabilities
Paasch, Valerie; Hoosier, Teresa M.; Accardo, Jennifer; Ewen, Joshua B.; Slifer, Keith J.
2013-01-01
Electroencephalograms (EEGs) and polysomnograms (PSGs) are critical and frequently ordered tests in the care of children with neurodevelopmental disabilities (NDD). Performing studies with this population can be very intimidating, given that the referral reasons and seizure types can be unique, and children with NDD may have any combination of behavioral or sensory challenges that can make it difficult to successfully complete a study. This article presents a variety of strategies that can be used to overcome these challenges through good preparation, patience, caregiver involvement, effective behavioral management techniques, and education about the medical aspects of EEG/PSG in NDD. This Technical Tips article features ideas and experiences from an EEG/PSG technologist, two board-certified child neurologists (one who is further certified in Clinical Neurophysiology, while the other is further certified in Sleep Medicine), and two behaviorally trained pediatric psychologists. PMID:23301283
Final Technical Report: Electrohydrodynamic Tip Streaming
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basaran, Osman
2016-01-06
When subjected to strong electric fields, liquid drops and films form conical tips and emit thin jets from their tips. Such electrodydrodynamic (EDH) tip streaming or cone-jetting phenomena, which are sometimes referred to as electrospraying, occur widely in nature, e.g., in ejection of streams of small charged drops from pointed tips of raindrops in thunderclouds, and technology, e.g., in electrospray mass spectrometry or electric field-driven solvent extraction. More recently, EHD cone-jetting has emerged as a powerful technique for direct printing of solar cells, micro- and nano- particle production, and microencapsulation for controlled release. In many of the aforementioned situations, ofmore » equal importance to the processes by which one drop disintegrates to form several drops are those by which (a) two drops come together and coalesce and (b) two drops are coupled to form a double droplet system (DDS) or a capillary switch (CS). the main objective of this research program is to advance through simulation, theory, and experiment the breakup, coalescence, and oscillatory dynamics of single and pairs of charged as well as uncharged drops.« less
Nasal tip plasty: the delivery approach revisited.
Xavier, Rui
2013-02-01
The delivery approach, though very appropriate for remodeling the tip of the nose, has been overlooked in recent years and has often been passed over for the open approach. One reason for this is the intercartilaginous incision used for the delivery approach, which may cause scarring at the nasal valve area, leading to postoperative functional obstruction of the nose. The delivery of the alar cartilages is another negative, as this maneuver will disrupt the collagen fibers that attach the upper lateral cartilages to the cephalic margin of the alar cartilages, leading to a weakening of the tip's support. We propose a modification to the traditional delivery approach by using a transcartilaginous instead of an intercartilaginous incision to prevent damage to the valve area. We also suggest taking advantage of the interference to the tip's support caused by the disruption of the collagen fibers of the scroll area. The purpose of this article is to describe this modification of the delivery approach and to emphasize the advantages that this controlled interference to the tip's support may have in selected cases. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Surgical Tips to Preserve the Facet Joint during Microdiscectomy
Park, Man-Kyu; Cho, Dae-Chul; Sung, Joo-Kyung
2013-01-01
Lumbar microdiscectomy (MD) is the gold standard for treatment of lumbar disc herniation. Generally, the surgeon attempts to protect the facet joint in hopes of avoiding postoperative pain/instability and secondary degenerative arthropathy. We believe that preserving the facet joint is especially important in young patients, owing to their life expectancy and activity. However, preserving the facet joint is not easy during lumbar MD. We propose several technical tips (superolateral extension of conventional laminotomy, oblique drilling for laminotomy, and additional foraminotomy) for facet joint preservation during lumbar MD. PMID:24294466
Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients
Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul
2013-01-01
In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276
Note: Microelectrode-shielding tip for scanning probe electron energy spectroscopy
NASA Astrophysics Data System (ADS)
Huang, Wei; Li, Zhean; Xu, Chunkai; Liu, Jian; Xu, Chunye; Chen, Xiangjun
2018-04-01
We report a novel microelectrode-shielding tip (ME tip) for scanning probe electron energy spectroscopy (SPEES). The shielding effect of this tip is studied through comparing the detection efficiency with the normal tip by both experiment and simulation. The results show that the backscattering count rate detected by the SPEES instrument using the normal tip begins to decrease as the tip approaches to the sample surface within 21 μm, while that using the ME tip only starts to drop off within 1 μm. This indicates that the electron energy spectra can be measured with the ME tip at a much closer tip-sample distance. Furthermore, it is also demonstrated that the ME tip can be used to obtain topography of the sample surface in situ simultaneously.
Orthopedic trauma surgery in the morbidly obese patient.
Bozzio, Anthony E; Gala, Raj J; Villasenor, Mario A; Hao, Jiandon; Mauffrey, Cyril
2014-05-01
The treatment of morbidly obese patients in orthopedic trauma differs in many ways compared to injured patients with normal body mass indices. This paper highlights key differences and ways to overcome obstacles. We present specific tips, as well as considerations for initial planning, positioning for surgery, intra-operative strategies, and a discussion on both anesthesia and imaging. Several treatment strategies have been shown to have better results in morbidly obese patients. Pre-operative planning is necessary for minimizing risk to the patient. The prevalence of morbid obesity has increased in the USA in the past quarter century. Treatment for orthopedic injuries in morbidly obese patients requires a multidisciplinary approach that addresses not only their orthopedic injuries, but also medical co-morbidities. A team of medicine doctors, anesthesiologists, X-ray technicians, physical and occupational therapists, respiratory therapists, and social workers is needed in addition to the orthopedic surgeon. Modifications in both pre-operative planning and intra-operative strategies may be necessary in order to accommodate the patient. This paper presents numerous technical tips that can aid in providing stable fixation for fractures, as well as addressing peri-operative issues specific to the morbidly obese.
NASA Astrophysics Data System (ADS)
Fronczak, Sean G.
The Hamaker constant, A, is a quantitative measure of the fundamental attractive van der Waals (vdW) interaction for microscale and nanoscale materials. This parameter captures each material's compositional effects on the vdW force, which is often needed as input for predicting the vdW interactions between particles and surfaces. Experimental attempts to determine A using an atomic force microscope (AFM) are typically hindered by issues inherent to the cantilever-tip-surface contact regime, such as surface roughness and deformation, and contact separation distance. Thus, we developed a new method for estimating Hamaker constants from the non-contact approach regime of an AFM experiment (Fronczak et al., 2017, Langmuir 33, 714-725). This method invokes a quasi-dynamic description of the cantilever tip's approach to contact, in which the inertial effects of the tip motion are accounted for when analyzing the trajectory of the tip's approach towards the substrate. The method was tested experimentally using silica, alumina and polystyrene substrates, and was demonstrated to yield estimates of A for these materials that were in very good agreement with previously published Lifshitz calculations. As with various other approaches to determining A, our new method relies heavily on the accuracy of the geometric model used to predict the interaction between the AFM tip and the substrate. For the initial validation experiments of our new method, we therefore focused on describing the shape of the cantilever tip as closely as possible, utilizing a complex model of a truncated pyramid with a spherical cap. Although this pyramidal geometry can be confirmed and the dimensions estimated via scanning electron microscopy (SEM), even high-resolution SEM images of the tip cannot provide sufficient detail to allow precise enough determination of the tip's geometric parameters. Consequently, we also propose an adaptation of the method, in which these difficult to quantify geometric effects are still fully captured via the convenient description of the tip as an 'effective' perfect sphere. Hence, the geometric complexity of the cantilever tip is no longer explicitly required for the determination of A. First, a tip is 'calibrated', whereby the deflection at first contact between the cantilever tip and a smooth surface of known vdW properties is determined and an effective radius, Reff, of the tip is calculated. The tip's approach to contact toward other similarly smooth surfaces can then be well-described by using only this single geometric parameter. We demonstrate the practicality and accuracy of this updated method by comparing the results with both the original pyramid model and Lifshitz approximations (when available) for flat substrates composed of silica, polystyrene, highly ordered pyrolytic graphite (HOPG), sapphire (alpha-Al3O2), Plexiglas (PMMA), and acrylonitrile butadiene styrene (ABS). Then, the modified quasi-dynamic model was employed to study the strength of the adhesive interaction between TNT and several swab materials which are used as explosive detection devices at security checkpoints. This information is crucial for the development and improvement of next-generation swab detection protocols to further advance this field. Finally, we also include the effects of thermal noise into our quasi-dynamic description of the cantilever motion to better understand how such noise might influence the accuracy of our method. We likewise determine, for the first time, the effects of instrument noise on the accuracy of other approach-to-contact methodologies for determining A.
Park, Sung Joon; Jeong, Woo-Jin; Ahn, Soon-Hyun
2017-11-01
The purpose of this study was to propose a novel, minimally invasive transaxillary approach for harvesting the scapular tip and latissimus dorsi osteomyogenous free flap for the reconstruction of a maxillectomy defect. A retrospective case series study of 4 patients who underwent reconstruction using a scapular tip composite free flap through the transaxillary approach was conducted. The data (age, sex, pathology, previous treatment and adjuvant treatment) were collected and analysed. Total operation time, number of hospital days and the cosmetic and functional outcome of reconstruction were analysed. Two male and two female patients were enrolled in this study. The patients' ages ranged from 52 to 59 years. All the patients had maxillectomy defects, with at least a classification of Okay type II, which were successfully reconstructed using a scapular tip and latissimus dorsi free flap through a minimally invasive transaxillary approach. The entire operation time for the primary tumour surgery and reconstruction ranged from 6.2 to 12.1 h (mean, 11.1 h). The average length of the hospital stay was 13 days (range, 10-16 days). No major donor site morbidity was observed, and there was no graft failure that required revision or exploration surgery. The minimally invasive transaxillary approach for harvesting the scapular tip and latissimus dorsi osteomyogenous free flap for the reconstruction of maxillectomy defect is a promising approach for more favourable functional and aesthetic outcomes when compared to the use of other bone containing free flaps and the classic approach for harvesting scapular tip and latissimus dorsi free flap. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Twenty-five years after the first TIPS in Spain.
Bilbao Jaureguízar, J I
2016-01-01
The incorporation, 25 years ago, of transjugular intrahepatic portosystemic shunting, better known by the acronym TIPS, represents an indisputable improvement in the treatment and management of patients with symptoms due to portal hypertension. This article discusses the origins of the technique and the technical innovations that have been progressively added through the years. The implantation of coated stents, which protect the stent from processes in the parenchymal track that can lead to stenosis, have helped ensure long-term patency, thus reducing the need for reintervention. Solid evidence from valuable publications has situated TIPS at the forefront of the treatment options in a wide variety of clinical situations associated with portal hypertension. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
TIP hypospadias repair: A pediatric urology indicator operation.
Snodgrass, Warren; Bush, Nicol
2016-02-01
We review development and evolution of TIP hypospadias repair, including technical changes made to improve its results. We also discuss general risk factors for hypospadias surgical complications. We describe use of a database with prospective data entry to first identify our most common complications and their frequency, and then to monitor results of technical modifications made to reduce their occurrence. Multiple logistic regression of various factors recorded in the database was done to identify those predicting increased risk for urethroplasty complications. Fistula and glans dehiscence are the two most common complications we encountered after TIP repair. Changes in urethral plate tubularization and barrier layers covering the neourethra resulted in a significant reduction in fistulas after proximal TIP. Changes in glansplasty sutures and use of preoperative testosterone to increase glans size did not reduce likelihood for dehiscence, whereas increasing the extent of glans wings dissection did. Logistic regression analysis confirmed proximal meatal location and reoperation predicted increased complications, but also identified glans width ≤ 14 mm as an independent risk factor for hypospadias urethroplasty complications. Systematic, prospective data collection facilitated identification of complications and their risk factors, and provided a means to assess results of modifications made to address them. Limiting the algorithm used for hypospadias repair increases expertise in those techniques used. Reported low surgical volumes for proximal hypospadias repair suggest subspecialization of these cases be carried out so that designated surgeons can achieve sufficient volume to analyze their results and make improvements. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
The TIPS Evaluation Project: A Theory-Driven Approach to Dissemination Research.
ERIC Educational Resources Information Center
Mulvey, Kevin P.; Hayashi, Susan W.; Hubbard, Susan M.; Kopstien, Andrea; Huang, Judy Y.
2003-01-01
Introduces the special section that focuses on four major studies under the treatment improvement protocols (TIPs) evaluation project. Provides an overview of each article, and addresses the value of using a theory-driven approach to dissemination research. (SLD)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Tevis D. B., E-mail: tjacobs@pitt.edu; Wabiszewski, Graham E.; Goodman, Alexander J.
2016-01-15
The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tipmore » has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture’s use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.« less
Miyayama, Shiro; Yamashiro, Masashi; Hattori, Yuki; Orito, Nobuaki; Matsui, Ken; Tsuji, Kazunobu; Yoshida, Miki; Matsui, Osamu
2011-05-01
The aim of this study was to evaluate the technical aspects of embolization using microcoils through a microcatheter with a tip of 2F or smaller during abdominal vascular interventions. Coil embolization through a microcatheter with a tip of 2F or smaller was attempted in 73 procedures. Two types of microcoil-Liquid Coil (Boston Scientific, Watertown, MA, USA) and Tornado Coil (Cook, Bloomington, IN, USA)-were deployed through four types of thinner microcatheter [2F tip (n = 49) and 1.8F tip (n = 24)]. Coil jams in the microcatheter and coil migration were evaluated. In total, 286 microcoils were placed (mean ± SD, 3.9 ± 4.3 coils per procedure, range 1-32 coils). In 19 procedures (26.9%), Liquid Coils were used alone. In 44 (60.3%), Tornado Coils were used alone. In 10 (13.7%), Liquid Coils and Tornado Coils were combined. There were no coil jams in the microcatheter in this series. One Tornado Coil (0.3%) delivered into the gastroduodenal artery migrated to the right hepatic artery. Liquid Coils and Tornado Coils can be placed through a thinner microcatheter without difficulty. However, there is a risk of coil migration in large vessels or at the proximal site because the catheter tip is not stabilized.
Dynamics of quiet human stance: computer simulations of a triple inverted pendulum model.
Günther, Michael; Wagner, Heiko
2016-01-01
For decades, the biomechanical description of quiet human stance has been dominated by the single inverted pendulum (SIP) paradigm. However, in the past few years, the SIP model family has been falsified as an explanatory approach. Double inverted pendulum models have recently proven to be inappropriate. Human topology with three major leg joints suggests in a natural way to examine triple inverted pendulum (TIP) models as an appropriate approach. In this study, we focused on formulating a TIP model that can synthesise stable balancing attractors based on minimalistic sensor information and actuation complexity. The simulated TIP oscillation amplitudes are realistic in vertical direction. Along with the horizontal ankle, knee and hip positions, though, all simulated joint angle amplitudes still exceed the measured ones about threefold. It is likely that they could be eventually brought down to the physiological range by using more sensor information. The TIP systems' eigenfrequency spectra come out as another major result. The eigenfrequencies spread across about 0.1 Hz...20 Hz. Our main result is that joint stiffnesses can be reduced even below statically required values by using an active hip torque balancing strategy. When reducing mono- and bi-articular stiffnesses further down to levels threatening dynamic stability, the spectra indicate a change from torus-like (stable) to strange (chaotic) attractors. Spectra of measured ground reaction forces appear to be strange-attractor-like. We would conclude that TIP models are a suitable starting point to examine more deeply the dynamic character of and the essential structural properties behind quiet human stance. Abbreviations and technical terms Inverted pendulum body exposed to gravity and pivoting in a joint around position of unstable equilibrium (operating point) SIP single inverted pendulum: one rigid body pivoting around fixation to the ground (external joint) DIP double inverted pendulum: two bodies; external and internal joint operate around instability TIP triple inverted pendulum: three bodies; external and both internal joints operate around instability QIP quadruple inverted pendulum: four bodies, foot replaces external joint; all three internal joints operate around instability Eigenfrequency characteristic frequency that a physical system is oscillating at when externally excited at a limited energy level DOF degree of freedom; in mechanics: linear displacement or angle or combination thereof Mono-articular stiffness: coefficient of proportionality between mechanical displacement of a DOF and restoring force/torque component in the respective DOF Bi-articular stiffness coefficient of proportionality between mechanical displacement of a DOF and restoring force/torque component in another DOF GRF ground reaction force HAT segment including head, arms and trunk COM centre of mass COP centre of pressure in the plane of the force platform surface.
On the diffusion of ferrocenemethanol in room-temperature ionic liquids: an electrochemical study.
Lovelock, Kevin R J; Ejigu, Andinet; Loh, Sook Fun; Men, Shuang; Licence, Peter; Walsh, Darren A
2011-06-07
The electrochemical behaviour of ferrocenemethanol (FcMeOH) has been studied in a range of room-temperature ionic liquids (RTILs) using cyclic voltammetry, chronoamperomery and scanning electrochemical microscopy (SECM). The diffusion coefficient of FcMeOH, measured using chronoamperometry, decreased with increasing RTIL viscosity. Analysis of the mass transport properties of the RTILs revealed that the Stokes-Einstein equation did not apply to our data. The "correlation length" was estimated from diffusion coefficient data and corresponded well to the average size of holes (voids) in the liquid, suggesting that a model in which the diffusing species jumps between holes in the liquid is appropriate in these liquids. Cyclic voltammetry at ultramicroelectrodes demonstrated that the ability to record steady-state voltammograms during ferrocenemethanol oxidation depended on the voltammetric scan rate, the electrode dimensions and the RTIL viscosity. Similarly, the ability to record steady-state SECM feedback approach curves depended on the RTIL viscosity, the SECM tip radius and the tip approach speed. Using 1.3 μm Pt SECM tips, steady-state SECM feedback approach curves were obtained in RTILs, provided that the tip approach speed was low enough to maintain steady-state diffusion at the SECM tip. In the case where tip-induced convection contributed significantly to the SECM tip current, this effect could be accounted for theoretically using mass transport equations that include diffusive and convective terms. Finally, the rate of heterogeneous electron transfer across the electrode/RTIL interface during ferrocenemethanol oxidation was estimated using SECM, and k(0) was at least 0.1 cm s(-1) in one of the least viscous RTILs studied.
NASA Technical Reports Server (NTRS)
Steeman, Gerald; Connell, Christopher
2000-01-01
Many librarians may feel that dynamic Web pages are out of their reach, financially and technically. Yet we are reminded in library and Web design literature that static home pages are a thing of the past. This paper describes how librarians at the Institute for Defense Analyses (IDA) library developed a database-driven, dynamic intranet site using commercial off-the-shelf applications. Administrative issues include surveying a library users group for interest and needs evaluation; outlining metadata elements; and, committing resources from managing time to populate the database and training in Microsoft FrontPage and Web-to-database design. Technical issues covered include Microsoft Access database fundamentals, lessons learned in the Web-to-database process (including setting up Database Source Names (DSNs), redesigning queries to accommodate the Web interface, and understanding Access 97 query language vs. Standard Query Language (SQL)). This paper also offers tips on editing Active Server Pages (ASP) scripting to create desired results. A how-to annotated resource list closes out the paper.
Ten Tips To Aid Teachers Creating Multimedia Presentations.
ERIC Educational Resources Information Center
Ennis, Willie; Ennis, Demetria
1996-01-01
Suggestions to help teachers create original multimedia presentations and lessons include building resource teams, knowing intellectual property and copyright issues, analyzing target audiences, carefully selecting media, considering hardware and software requirements, seeking technical support, encouraging distribution on the World Wide Web,…
Time To Talk with Your Health Care Providers: 4 Tips to Start the Conversation
... Y Z 4 Tips: Start Talking With Your Health Care Providers About Complementary Health Approaches Share: When patients ... fully informed and can help patients make wise health care decisions. Here are 4 tips to help you ...
Twelve tips for "flipping" the classroom.
Moffett, Jennifer
2015-04-01
The flipped classroom is a pedagogical model in which the typical lecture and homework elements of a course are reversed. The following tips outline the steps involved in making a successful transition to a flipped classroom approach. The tips are based on the available literature alongside the author's experience of using the approach in a medical education setting. Flipping a classroom has a number of potential benefits, for example increased educator-student interaction, but must be planned and implemented carefully to support effective learning.
Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.
Parra, Dimitri A
2015-01-01
The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.
Onyx (Ethylene-vinyl Alcohol Copolymer) in Peripheral Applications
Guimaraes, Marcelo; Wooster, Mathew
2011-01-01
Onyx is a nonadhesive liquid embolic agent approved for the treatment of brain arteriovenous malformations. Here, the use of Onyx is discussed in different peripheral procedures. The Onyx's features, its manipulation, technical details, tips, and tricks are presented followed by illustrative cases. PMID:22942553
(Dry) arthroscopic partial wrist arthrodesis: tips and tricks.
del Piñal, F; Tandioy-Delgado, F
2014-10-01
One of the options for performing a partial wrist arthrodesis is the arthroscopic technique. As a first advantage arthroscopy allows us to directly assess the state of the articular surface of the carpal bones and define the best surgical option during the salvage operation. Furthermore, it allows performance of the procedure with minimal ligament damage and minimal interference with the blood supply of the carpals. These will (presumably) entail less capsular scarring and more rapid healing. Lastly, there is cosmetic benefit by reducing the amount of external scarring. The procedure has a steep learning curve even for accomplished arthroscopists but can be performed in a competitive manner to the open procedure if the dry technique is used. The aim of this paper is to present the technical details, tricks and tips to make the procedure accessible to all hand specialists with an arthroscopic interest. As it is paramount that the surgeon is acquainted with the "dry" technique, some technical details about it will also be presented. © Georg Thieme Verlag KG Stuttgart · New York.
Klinger, Christoph; Riecken, Bettina; Schmidt, Arthur; De Gottardi, Andrea; Meier, Benjamin; Bosch, Jaime; Caca, Karel
2018-03-01
To determine safety and efficacy of transjugular portal vein recanalization with creation of intrahepatic portosystemic shunt (PVR-TIPS) in patients with chronic non-cirrhotic, non-malignant portal vein thrombosis (PVT). This retrospective study includes 17 consecutive patients with chronic non-cirrhotic PVT (cavernous transformation n = 15). PVR-TIPS was indicated because of variceal bleeding (n = 13), refractory ascites (n = 2), portal biliopathy with recurrent cholangitis (n = 1), or abdominal pain (n = 1). Treatment consisted of a combination of transjugular balloon angioplasty, mechanical thrombectomy, and-depending on extent of residual thrombosis-transjugular intrahepatic portosystemic shunt and additional stenting of the portal venous system. Recanalization was successful in 76.5 % of patients despite cavernous transformation in 88.2 %. Both 1- and 2-year secondary PV and TIPS patency rates were 69.5 %. Procedure-related bleeding complications occurred in 2 patients (intraperitoneal bleeding due to capsule perforation, n = 1; liver hematoma, n = 1) and resolved spontaneously. However, 1 patient died due to subsequent nosocomial pneumonia. During follow-up, 3 patients with TIPS occlusion and PVT recurrence experienced portal hypertensive complications. PVR-TIPS is safe and effective in selected patients with chronic non-cirrhotic PVT. Due to technical complexity and possible complications, it should be performed only in specialized centers with high experience in TIPS procedures. © Georg Thieme Verlag KG Stuttgart · New York.
Modeling the Interaction between AFM Tips and Pinned Surface Nanobubbles.
Guo, Zhenjiang; Liu, Yawei; Xiao, Qianxiang; Schönherr, Holger; Zhang, Xianren
2016-01-26
Although the morphology of surface nanobubbles has been studied widely with different AFM modes, AFM images may not reflect the real shapes of the nanobubbles due to AFM tip-nanobubble interactions. In addition, the interplay between surface nanobubble deformation and induced capillary force has not been well understood in this context. In our work we used constraint lattice density functional theory to investigate the interaction between AFM tips and pinned surface nanobubbles systematically, especially concentrating on the effects of tip hydrophilicity and shape. For a hydrophilic tip contacting a nanobubble, its hydrophilic nature facilitates its departure from the bubble surface, displaying a weak and intermediate-range attraction. However, when the tip squeezes the nanobubble during the approach process, the nanobubble shows an elastic effect that prevents the tip from penetrating the bubble, leading to a strong nanobubble deformation and repulsive interactions. On the contrary, a hydrophobic tip can easily pierce the vapor-liquid interface of the nanobubble during the approach process, leading to the disappearance of the repulsive force. In the retraction process, however, the adhesion between the tip and the nanobubble leads to a much stronger lengthening effect on nanobubble deformation and a strong long-range attractive force. The trends of force evolution from our simulations agree qualitatively well with recent experimental AFM observations. This favorable agreement demonstrates that our model catches the main intergradient of tip-nanobubble interactions for pinned surface nanobubbles and may therefore provide important insight into how to design minimally invasive AFM experiments.
Solar Photovoltaics Technology: The Revolution Begins . . .
NASA Astrophysics Data System (ADS)
Kazmerski, Lawrence
2009-11-01
The prospects of current and coming solar-photovoltaic (PV) technologies are envisioned, arguing this solar-electricity source is at a tipping point in the complex worldwide energy outlook. The emphasis of this presentation is on R&D advances (cell, materials, and module options), with indications of the limitations and strengths of crystalline (Si and GaAs) and thin-film (a-Si:H, Si, Cu(In,Ga)(Se,S)2, CdTe). The contributions and technological pathways for now and near-term technologies (silicon, III-Vs, and thin films) and status and forecasts for next- generation PV (organics, nanotechnologies, non-conventional junction approaches) are evaluated. Recent advances in concentrators with efficiencies headed toward 50%, new directions for thin films (20% and beyond), and materials/device technology issues are discussed in terms of technology progress. Insights into technical and other investments needed to tip photovoltaics to its next level of contribution as a significant clean-energy partner in the world energy portfolio. The need for R&D accelerating the now and imminent (evolutionary) technologies balanced with work in mid-term (disruptive) approaches is highlighted. Moreover, technology progress and ownership for next generation solar PV mandates a balanced investment in research on longer-term (the revolution needs revolutionary approaches to sustain itself) technologies (quantum dots, multi-multijunctions, intermediate-band concepts, nanotubes, bio-inspired, thermophotonics, solar hydrogen. . . ) having high-risk, but extremely high performance and cost returns for our next generations of energy consumers. Issues relating to manufacturing are explored-especially with the requirements for the next-generation technologies. This presentation provides insights into how this technology has developed-and where the R&D investments should be made and we can expect to be by this mid-21st century.
Nanometal Skin of Plasmonic Heterostructures for Highly Efficient Near-Field Scattering Probes
NASA Astrophysics Data System (ADS)
Zito, Gianluigi; Rusciano, Giulia; Vecchione, Antonio; Pesce, Giuseppe; di Girolamo, Rocco; Malafronte, Anna; Sasso, Antonio
2016-08-01
In this work, atomic force microscopy probes are functionalized by virtue of self-assembling monolayers of block copolymer (BCP) micelles loaded either with clusters of silver nanoparticles or bimetallic heterostructures consisting of mixed species of silver and gold nanoparticles. The resulting self-organized patterns allow coating the tips with a sort of nanometal skin made of geometrically confined nanoislands. This approach favors the reproducible engineering and tuning of the plasmonic properties of the resulting structured tip by varying the nanometal loading of the micelles. The newly conceived tips are applied for experiments of tip-enhanced Raman scattering (TERS) spectroscopy and scattering-type scanning near-field optical microscopy (s-SNOM). TERS and s-SNOM probe characterizations on several standard Raman analytes and patterned nanostructures demonstrate excellent enhancement factor with the possibility of fast scanning and spatial resolution <12 nm. In fact, each metal nanoisland consists of a multiscale heterostructure that favors large scattering and near-field amplification. Then, we verify the tips to allow challenging nongap-TER spectroscopy on thick biosamples. Our approach introduces a synergistic chemical functionalization of the tips for versatile inclusion and delivery of plasmonic nanoparticles at the tip apex, which may promote the tuning of the plasmonic properties, a large enhancement, and the possibility of adding new degrees of freedom for tip functionalization.
The effect of the serum corona on interactions between a single nano-object and a living cell
NASA Astrophysics Data System (ADS)
Dror, Yael; Sorkin, Raya; Brand, Guy; Boubriak, Olga; Urban, Jill; Klein, Jacob
2017-04-01
Nanoparticles (NPs) which enter physiological fluids are rapidly coated by proteins, forming a so-called corona which may strongly modify their interaction with tissues and cells relative to the bare NPs. In this work the interactions between a living cell and a nano-object, and in particular the effect on this of the adsorption of serum proteins, are directly examined by measuring the forces arising as an Atomic Force Microscope tip (diameter 20 nm) - simulating a nano-object - approaches and contacts a cell. We find that the presence of a serum protein corona on the tip strongly modifies the interaction as indicated by pronounced increase in the indentation, hysteresis and work of adhesion compared to a bare tip. Classically one expects an AFM tip interacting with a cell surface to be repelled due to cell elastic distortion, offset by tip-cell adhesion, and indeed such a model fits the bare-tip/cell interaction, in agreement with earlier work. However, the force plots obtained with serum-modified tips are very different, indicating that the cell is much more compliant to the approaching tip. The insights obtained in this work may promote better design of NPs for drug delivery and other nano-medical applications.
The effect of the serum corona on interactions between a single nano-object and a living cell
Dror, Yael; Sorkin, Raya; Brand, Guy; Boubriak, Olga; Urban, Jill; Klein, Jacob
2017-01-01
Nanoparticles (NPs) which enter physiological fluids are rapidly coated by proteins, forming a so-called corona which may strongly modify their interaction with tissues and cells relative to the bare NPs. In this work the interactions between a living cell and a nano-object, and in particular the effect on this of the adsorption of serum proteins, are directly examined by measuring the forces arising as an Atomic Force Microscope tip (diameter 20 nm) - simulating a nano-object - approaches and contacts a cell. We find that the presence of a serum protein corona on the tip strongly modifies the interaction as indicated by pronounced increase in the indentation, hysteresis and work of adhesion compared to a bare tip. Classically one expects an AFM tip interacting with a cell surface to be repelled due to cell elastic distortion, offset by tip-cell adhesion, and indeed such a model fits the bare-tip/cell interaction, in agreement with earlier work. However, the force plots obtained with serum-modified tips are very different, indicating that the cell is much more compliant to the approaching tip. The insights obtained in this work may promote better design of NPs for drug delivery and other nano-medical applications. PMID:28383528
Tip-enhanced Raman mapping with top-illumination AFM.
Chan, K L Andrew; Kazarian, Sergei G
2011-04-29
Tip-enhanced Raman mapping is a powerful, emerging technique that offers rich chemical information and high spatial resolution. Currently, most of the successes in tip-enhanced Raman scattering (TERS) measurements are based on the inverted configuration where tips and laser are approaching the sample from opposite sides. This results in the limitation of measurement for transparent samples only. Several approaches have been developed to obtain tip-enhanced Raman mapping in reflection mode, many of which involve certain customisations of the system. We have demonstrated in this work that it is also possible to obtain TERS nano-images using an upright microscope (top-illumination) with a gold-coated Si atomic force microscope (AFM) cantilever without significant modification to the existing integrated AFM/Raman system. A TERS image of a single-walled carbon nanotube has been achieved with a spatial resolution of ∼ 20-50 nm, demonstrating the potential of this technique for studying non-transparent nanoscale materials.
Force microscopy of layering and friction in an ionic liquid
NASA Astrophysics Data System (ADS)
Hoth, Judith; Hausen, Florian; Müser, Martin H.; Bennewitz, Roland
2014-07-01
The mechanical properties of the ionic liquid 1-butyl-1-methylpyrrolidinium tris(pentafluoroethyl) trifluorophosphate ([Py1,4][FAP]) in confinement between a SiOx and a Au(1 1 1) surface are investigated by means of atomic force microscopy (AFM) under electrochemical control. Up to 12 layers of ion pairs can be detected through force measurements while approaching the tip of the AFM to the surface. The particular shape of the force versus distance curve is explained by a model for the interaction between tip, gold surface and ionic liquid, which assumes an exponentially decaying oscillatory force originating from bulk liquid density correlations. Jumps in the tip-sample distance upon approach correspond to jumps of the compliant force sensor between branches of the oscillatory force curve. Frictional force between the laterally moving tip and the surface is detected only after partial penetration of the last double layer between tip and surface.
Personal Consumerism. Courseware Evaluation for Vocational and Technical Education.
ERIC Educational Resources Information Center
Smizer, Janet; And Others
This courseware evaluation rates the "Personal Consumerism" program developed by Aquarius People Materials. (The eight-program series--not contained in this document--includes understanding labels, consumer help, consumer fraud, consumer law, comparative shopping, consumerism and you, reading an advertisement, and tips on buying a used…
Acoustic flight tests of rotorcraft noise-abatement approaches using local differential GPS guidance
NASA Technical Reports Server (NTRS)
Chen, Robert T. N.; Hindson, William S.; Mueller, Arnold W.
1995-01-01
This paper presents the test design, instrumentation set-up, data acquisition, and the results of an acoustic flight experiment to study how noise due to blade-vortex interaction (BVI) may be alleviated. The flight experiment was conducted using the NASA/Army Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) research helicopter. A Local Differential Global Positioning System (LDGPS) was used for precision navigation and cockpit display guidance. A laser-based rotor state measurement system on board the aircraft was used to measure the main rotor tip-path-plane angle-of-attack. Tests were performed at Crows Landing Airfield in northern California with an array of microphones similar to that used in the standard ICAO/FAA noise certification test. The methodology used in the design of a RASCAL-specific, multi-segment, decelerating approach profile for BVI noise abatement is described, and the flight data pertaining to the flight technical errors and the acoustic data for assessing the noise reduction effectiveness are reported.
Variation of the energy release rate as a crack approaches and passes through an elastic inclusion
NASA Astrophysics Data System (ADS)
Li, Rongshun; Chudnovsky, A.
1993-02-01
The variation of the energy release rate (ERP) at the tip of a crack penetrating an elastic inclusion is analyzed using an approach involving modeling the random array of microcracks or other defects by an elastic inclusion with effective elastic properties. Computations are carried out using a finite element procedure. The eight-noded isoparametric serendipity element with the shift of the midpoint to the quarter-point is used to simulate the singularity at the crack tip, and the crack growth is accommodated by implementing a mesh regeneration technique. The ERP values were calculated for various crack tip positions which simulate the process of the crack approaching and penetrating the inclusion.
Variation of the energy release rate as a crack approaches and passes through an elastic inclusion
NASA Technical Reports Server (NTRS)
Li, Rongshun; Chudnovsky, A.
1993-01-01
The variation of the energy release rate (ERP) at the tip of a crack penetrating an elastic inclusion is analyzed using an approach involving modeling the random array of microcracks or other defects by an elastic inclusion with effective elastic properties. Computations are carried out using a finite element procedure. The eight-noded isoparametric serendipity element with the shift of the midpoint to the quarter-point is used to simulate the singularity at the crack tip, and the crack growth is accommodated by implementing a mesh regeneration technique. The ERP values were calculated for various crack tip positions which simulate the process of the crack approaching and penetrating the inclusion.
Dorafshar, Amir H; Januszyk, Michael; Song, David H
2010-08-01
Techniques for autologous breast reconstruction have evolved to minimize donor-site morbidity and reduce flap-specific complications. When available, the superficial inferior epigastric artery (SIEA) flap represents the optimal method to achieve the former. However, many microsurgeons have been reluctant to adopt this procedure due to technical challenges inherent to the surgery, as well as concerns with the intrinsic capacity of the superficial vessel system to adequately support this flap. This article sets forth a simple approach to the SIEA flap harvest and demonstrates that favorable results may be achieved even for small caliber vessels. A total of 46 patients underwent 53 SIEA breast reconstructions over a 6-year period using a modified approach for pedicle dissection and arterial inclusion criteria solely on the basis of presence of a palpable pulse. Average pedicle length harvested for all SIEA flaps was 6.07 cm; and mean arterial (0.96 mm) and venous (2.27 mm) diameters represent the lowest published values. Three flaps (5.7%) demonstrated fat necrosis or partial flap necrosis, with one (1.9%) complete flap loss. These results compare favorably with those of previous SIEA series employing diameter-based selection criteria, suggesting that the presence of a palpable arterial pulse may be sufficient to permit successful utilization of this flap. (c) Thieme Medical Publishers.
Surgical management of coracoid fractures: technical tricks and clinical experience.
Hill, Brian W; Jacobson, Aaron R; Anavian, Jack; Cole, Peter A
2014-05-01
The coracoid process plays a pivotal role in the foundation of the coracoacromial arch and in cases of displaced fractures; surgical management may be warranted to avoid functional compromise or impingement. A direct approach through Langer's lines allows for easy exposure and direct visualization for an anatomic reduction of simple fractures through the shaft or base of the coracoid. An anterior approach for fractures that extend into the superior glenoid fossa allows for direct exposure to obtain an anatomic articular reduction and indirect reduction of the coracoid fracture. In cases where a complex glenoid or scapula neck/body fracture is being addressed simultaneously either a posterior Judet approach can be used with an indirect reduction method or a separate anterior approach must be combined to address it if not in continuity with the superior scapular segment. Implant selection, primarily interfragmentary screws or a buttress plate, should be based on the size of the fragment, the degree of comminution, and the degree of articular involvement to ensure adequate stabilization. The purpose of this manuscript was to describe a stepwise approach to the surgical management of displaced coracoid fractures, describe surgical tips and techniques, and to present the clinical outcomes in 22 patients after surgical treatment with this approach.
NASA Astrophysics Data System (ADS)
Park, Kyoung-Duck; Raschke, Markus B.
2018-05-01
Controlling the propagation and polarization vectors in linear and nonlinear optical spectroscopy enables to probe the anisotropy of optical responses providing structural symmetry selective contrast in optical imaging. Here we present a novel tilted antenna-tip approach to control the optical vector-field by breaking the axial symmetry of the nano-probe in tip-enhanced near-field microscopy. This gives rise to a localized plasmonic antenna effect with significantly enhanced optical field vectors with control of both \\textit{in-plane} and \\textit{out-of-plane} components. We use the resulting vector-field specificity in the symmetry selective nonlinear optical response of second-harmonic generation (SHG) for a generalized approach to optical nano-crystallography and -imaging. In tip-enhanced SHG imaging of monolayer MoS$_2$ films and single-crystalline ferroelectric YMnO$_3$, we reveal nano-crystallographic details of domain boundaries and domain topology with enhanced sensitivity and nanoscale spatial resolution. The approach is applicable to any anisotropic linear and nonlinear optical response, and provides for optical nano-crystallographic imaging of molecular or quantum materials.
Newton, J Stephen; Horner, Robert H; Algozzine, Bob; Todd, Anne W; Algozzine, Kate
2012-08-01
Members of Positive Behavior Interventions and Supports (PBIS) teams from 34 elementary schools participated in a Team-Initiated Problem Solving (TIPS) Workshop and follow-up technical assistance. Within the context of a randomized wait-list controlled trial, team members who were the first recipients of the TIPS intervention demonstrated greater implementation integrity in using the problem-solving processes during their team meetings than did members of PBIS Teams in the Wait-List Control group. The success of TIPS at improving implementation integrity of the problem-solving processes is encouraging and suggests the value of conducting additional research focused on determining whether there is a functional relation between use of these problem-solving processes and actual resolution of targeted student academic and social problems. Copyright © 2012 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Sensing mode atomic force microscope
Hough, Paul V. C.; Wang, Chengpu
2003-01-01
An atomic force microscope utilizes a pulse release system and improved method of operation to minimize contact forces between a probe tip affixed to a flexible cantilever and a specimen being measured. The pulse release system includes a magnetic particle affixed proximate the probe tip and an electromagnetic coil. When energized, the electromagnetic coil generates a magnetic field which applies a driving force on the magnetic particle sufficient to overcome adhesive forces exhibited between the probe tip and specimen. The atomic force microscope includes two independently displaceable piezo elements operable along a Z-axis. A controller drives the first Z-axis piezo element to provide a controlled approach between the probe tip and specimen up to a point of contact between the probe tip and specimen. The controller then drives the first Z-axis piezo element to withdraw the cantilever from the specimen. The controller also activates the pulse release system which drives the probe tip away from the specimen during withdrawal. Following withdrawal, the controller adjusts the height of the second Z-axis piezo element to maintain a substantially constant approach distance between successive samples.
Martins, Ana; Vieira, Helena; Gaspar, Helena; Santos, Susana
2014-01-01
The marine environment harbors a number of macro and micro organisms that have developed unique metabolic abilities to ensure their survival in diverse and hostile habitats, resulting in the biosynthesis of an array of secondary metabolites with specific activities. Several of these metabolites are high-value commercial products for the pharmaceutical and cosmeceutical industries. The aim of this review is to outline the paths of marine natural products discovery and development, with a special focus on the compounds that successfully reached the market and particularly looking at the approaches tackled by the pharmaceutical and cosmetic companies that succeeded in marketing those products. The main challenges faced during marine bioactives discovery and development programs were analyzed and grouped in three categories: biodiversity (accessibility to marine resources and efficient screening), supply and technical (sustainable production of the bioactives and knowledge of the mechanism of action) and market (processes, costs, partnerships and marketing). Tips to surpass these challenges are given in order to improve the market entry success rates of highly promising marine bioactives in the current pipelines, highlighting what can be learned from the successful and unsuccessful stories that can be applied to novel and/or ongoing marine natural products discovery and development programs. PMID:24549205
CT-Guided Interventions Using a Free-Hand, Optical Tracking System: Initial Clinical Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schubert, Tilman, E-mail: TSchubert@uhbs.ch; Jacob, Augustinus L.; Pansini, Michele
2013-08-01
PurposeThe present study was designed to evaluate the geometrical accuracy and clinical applicability of a new, free-hand, CT-guided, optical navigation system.MethodsFifteen procedures in 14 consecutive patients were retrospectively analyzed. The navigation system was applied for interventional procedures on small target lesions, in cases with long needle paths, narrow access windows, or when an out-of-plane access was expected. Mean lesion volume was 27.9 ml, and mean distance to target measured was 107.5 mm. Eleven of 15 needle trajectories were planned as out-of-plane approaches regarding the axial CT plane.ResultsNinety-one percent of the biopsies were diagnostic. All therapeutic interventions were technically successful. Targetingmore » precision was high with a mean distance of the needle tip from planned target of 1.98 mm. Mean intervention time was 1:12 h. A statistically significant correlation between angular needle deviation and intervention time (p = 0.007), respiratory movement of the target (p = 0.008), and body mass index (p = 0.02) was detected. None of the evaluated parameters correlated significantly with the distance from the needle tip to the planned target.ConclusionsThe application of a navigation system for complex CT-guided procedures provided safe and effective targeting within a reasonable intervention time in our series.« less
Saad, Wael E A; Schwaner, Sandra; Lippert, Allison; Sabri, Saher S; Al-Osaimi, Abdullah; Matsumoto, Alan H; Angle, John F; Caldwell, Stephen
2014-12-01
The management of parastomal varices is not established. Transjugular intrahepatic portosystemic shunt (TIPS) creation is the most commonly described treatment; however, the rebleed rate after TIPS is 21-37%. The purpose of the study is to determine the effectiveness of transvenous obliteration using sodium tetradecyl sulfate (STS) and to describe a new simplified technique in obliterating these varices. Four patients are presented who underwent transvenous obliteration using STS. One was obliterated using balloon occlusion from the systemic veins, the second was obliterated without balloon from a transhepatic antegrade approach, and the last two patients were obliterated using the direct antegrade technique. This simplified technique requires only a micropuncture kit (not requiring balloons or coils) and ultrasound transducer compression of the systemic draining veins, relying on high portal pressure to keep the sclerosant confined to the varices. The sclerosant is essentially trapped between the portal pressure and the ultrasound-transducer compression (10-15 min). Technical success was achieved in all four patients without procedural or postprocedural complications and no rebleeding for a mean follow-up of 17 (range 2-33) months. Transvenous obliteration of parastomal varices utilizing STS as a sclerosant is safe and effective. The newly described technique is simple, feasible, and requires minimal equipment (no balloons or coils or catheters).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward
PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloonmore » retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.« less
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Antennas. 95.859 Section 95.859... SERVICES 218-219 MHz Service Technical Standards § 95.859 Antennas. (a) The overall height from ground to topmost tip of the CTS antenna shall not exceed the height necessary to assure adequate service. Certain...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Antennas. 95.859 Section 95.859... SERVICES 218-219 MHz Service Technical Standards § 95.859 Antennas. (a) The overall height from ground to topmost tip of the CTS antenna shall not exceed the height necessary to assure adequate service. Certain...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Antennas. 95.859 Section 95.859... SERVICES 218-219 MHz Service Technical Standards § 95.859 Antennas. (a) The overall height from ground to topmost tip of the CTS antenna shall not exceed the height necessary to assure adequate service. Certain...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Antennas. 95.859 Section 95.859... SERVICES 218-219 MHz Service Technical Standards § 95.859 Antennas. (a) The overall height from ground to topmost tip of the CTS antenna shall not exceed the height necessary to assure adequate service. Certain...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Antennas. 95.859 Section 95.859... SERVICES 218-219 MHz Service Technical Standards § 95.859 Antennas. (a) The overall height from ground to topmost tip of the CTS antenna shall not exceed the height necessary to assure adequate service. Certain...
Mason, Katrina A; Theodorakopoulou, Evgenia; Pafitanis, Georgios; Ghanem, Ali M; Myers, Simon R
2016-09-01
Microsurgery is used in a variety of surgical specialties, including Plastic Surgery, Maxillofacial Surgery, Ophthalmic Surgery, Otolaryngology and Neurosurgery. It is considered one of the most technically challenging fields of surgery. Microsurgical skills demand fine, precise and controlled movements, and microsurgical skill acquisition has a steep initial learning curve. Microsurgical simulation provides a safe environment for skill acquisition before operating clinically. The traditional starting point for anyone wanting to pursue microsurgery is a basic simulation training course. We present twelve tips for postgraduate and undergraduate medics on how to set up and run a basic ex-vivo microsurgery simulation training course suitable for their peers.
Integrated Turbine Tip Clearance and Gas Turbine Engine Simulation
NASA Technical Reports Server (NTRS)
Chapman, Jeffryes W.; Kratz, Jonathan; Guo, Ten-Huei; Litt, Jonathan
2016-01-01
Gas turbine compressor and turbine blade tip clearance (i.e., the radial distance between the blade tip of an axial compressor or turbine and the containment structure) is a major contributing factor to gas path sealing, and can significantly affect engine efficiency and operational temperature. This paper details the creation of a generic but realistic high pressure turbine tip clearance model that may be used to facilitate active tip clearance control system research. This model uses a first principles approach to approximate thermal and mechanical deformations of the turbine system, taking into account the rotor, shroud, and blade tip components. Validation of the tip clearance model shows that the results are realistic and reflect values found in literature. In addition, this model has been integrated with a gas turbine engine simulation, creating a platform to explore engine performance as tip clearance is adjusted. Results from the integrated model explore the effects of tip clearance on engine operation and highlight advantages of tip clearance management.
Early warning of climate tipping points
NASA Astrophysics Data System (ADS)
Lenton, Timothy M.
2011-07-01
A climate 'tipping point' occurs when a small change in forcing triggers a strongly nonlinear response in the internal dynamics of part of the climate system, qualitatively changing its future state. Human-induced climate change could push several large-scale 'tipping elements' past a tipping point. Candidates include irreversible melt of the Greenland ice sheet, dieback of the Amazon rainforest and shift of the West African monsoon. Recent assessments give an increased probability of future tipping events, and the corresponding impacts are estimated to be large, making them significant risks. Recent work shows that early warning of an approaching climate tipping point is possible in principle, and could have considerable value in reducing the risk that they pose.
Design and performance of a beetle-type double-tip scanning tunneling microscope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaschinsky, Philipp; Coenen, Peter; Pirug, Gerhard
2006-09-15
A combination of a double-tip scanning tunneling microscope with a scanning electron microscope in ultrahigh vacuum environment is presented. The compact beetle-type design made it possible to integrate two independently driven scanning tunneling microscopes in a small space. Moreover, an additional level for coarse movement allows the decoupling of the translation and approach of the tunneling tip. The position of the two tips can be controlled from the millimeter scale down to 50 nm with the help of an add-on electron microscope. The instrument is capable of atomic resolution imaging with each tip.
Smart helicopter rotor with active blade tips
NASA Astrophysics Data System (ADS)
Bernhard, Andreas Paul Friedrich
2000-10-01
The smart active blade tip (SABT) rotor is an on-blade rotor vibration reduction system, incorporating active blade tips that can be independently pitched with respect to the main blade. The active blade tip rotor development included an experimental test program culminating in a Mach scale hover test, and a parallel development of a coupled, elastic actuator and rotor blade analysis for preliminary design studies and hover performance prediction. The experimental testing focussed on a small scale rotor on a bearingless Bell-412 hub. The fabricated Mach-scale active-tip rotor has a diameter of 1.524 m, a blade chord of 76.2 mm and incorporated a 10% span active tip. The nominal operating speed is 2000 rpm, giving a tip Mach number of 0.47. The blade tips are driven by a novel piezo-induced bending-torsion coupled actuator beam, located spanwise in the hollow mid-cell of the main rotor blade. In hover at 2000 rpm, at 2 deg collective, and for an actuation of 125 Vrms, the measured blade tip deflection at the first four rotor harmonics is between +/-1.7 and +/-2.8 deg, increasing to +/-5.3 deg at 5/rev with resonant amplification. The corresponding oscillatory amplitude of the rotor thrust coefficient is between 0.7 · 10-3 and 1.3 · 10-1 at the first four rotor harmonics, increasing to 2.1 · 10-3 at 5/rev. In general, the experimental blade tip frequency response and corresponding rotor thrust response are well captured by the analysis. The flexbeam root flap bending moment is predicted in trend, but is significantly over-estimated. The blade tips did not deflect as expected at high collective settings, because of the blade tip shaft locking up in the bearing. This is caused by the high flap bending moment on the blade tip shaft. Redesign of the blade tip shaft assembly and bearing support is identified as the primary design improvement for future research. The active blade tip rotor was also used as a testbed for the evaluation of an adaptive neural-network based control algorithm. Effective background vibration reduction of an intentional 1/rev hover imbalance was demonstrated. The control algorithm also showed the capability to generate desired multi-frequency control loads on the hub, based on artificial signal injection into the vibration measurement. The research program demonstrates the technical feasibility of the active blade tip concept for vibration reduction and warrants further investigation in terms of closed loop forward flight tests in the windtunnel and full scale design studies.
ERIC Educational Resources Information Center
What Works Clearinghouse, 2017
2017-01-01
Instructional tips help educators carry out recommendations contained in IES Educator's Practice Guides. The tips, based on a practice guide authored by Steve Graham, Alisha Bollinger, Carol Booth Olson, Catherine D'Aoust, Charles MacArthur, Deborah McCutchen, and Natalie Olinghouse, translate these recommendations into actionable approaches that…
Nanostar probes for tip-enhanced spectroscopy
NASA Astrophysics Data System (ADS)
Kim, Woong; Kim, Nara; Park, Joon Won; Kim, Zee Hwan
2015-12-01
To overcome the current limit of tip-enhanced spectroscopy that is based on metallic nano-probes, we developed a new scanning probe with a metallic nanostar, a nanoparticle with sharp spikes. A Au nanoparticle of 5 nm was first attached to the end of a tip through DNA-DNA hybridization and mechanical pick-up. The nanoparticle was converted to a nanostar with a core diameter of ~70 nm and spike lengths between 50 nm and 80 nm through the reduction of Au3+ with ascorbic acid in the presence of Ag+. Fabrication yields of such tips exceeded 60%, and more than 80% of such tips showed a mechanical durability sufficient for use in scanning microscopy. Effectiveness of the new probes for tip-enhanced Raman scattering (TERS) and tip-enhanced fluorescence (TEF) was confirmed. The probes exhibited the necessary enhancement for TEF, and the tip-on and tip-off ratios varied between 5 and 100. This large tip-to-tip variability may arise from the uncontrolled orientation of the apexes of the spike with respect to the sample surface, which calls for further fabrication improvement. The result overall supports a new fabrication approach for the probe that is effective for tip-enhanced spectroscopy.To overcome the current limit of tip-enhanced spectroscopy that is based on metallic nano-probes, we developed a new scanning probe with a metallic nanostar, a nanoparticle with sharp spikes. A Au nanoparticle of 5 nm was first attached to the end of a tip through DNA-DNA hybridization and mechanical pick-up. The nanoparticle was converted to a nanostar with a core diameter of ~70 nm and spike lengths between 50 nm and 80 nm through the reduction of Au3+ with ascorbic acid in the presence of Ag+. Fabrication yields of such tips exceeded 60%, and more than 80% of such tips showed a mechanical durability sufficient for use in scanning microscopy. Effectiveness of the new probes for tip-enhanced Raman scattering (TERS) and tip-enhanced fluorescence (TEF) was confirmed. The probes exhibited the necessary enhancement for TEF, and the tip-on and tip-off ratios varied between 5 and 100. This large tip-to-tip variability may arise from the uncontrolled orientation of the apexes of the spike with respect to the sample surface, which calls for further fabrication improvement. The result overall supports a new fabrication approach for the probe that is effective for tip-enhanced spectroscopy. Electronic supplementary information (ESI) available: Illustrations of TERS and TEF experiments, information about the TEM images, scheme of surface preparation and peak assignments of TERS spectra. See DOI: 10.1039/c5nr06657c
Tip rhinoplasty--a modified delivery approach.
Xavier, Rui
2009-06-01
For many cases of tip surgery a delivery approach is selected. If the patient has long alar cartilages, it may be difficult to deliver the cartilages without twisting or tearing the domes. In such a patient, a modified delivery approach may be easier to perform. For the modified delivery approach a transcartilaginous incision is first made and cephalic resection of the alar cartilage is performed. Then a marginal incision is made, and the remaining alar cartilage is dissected and easily delivered. After both alar cartilages being delivered, they are compared, and, if necessary, further resection is done in order to achieve perfect symmetry or to achieve the desired size of the cartilages. The cartilages may then be grafted, sutured or modified as considered necessary. We have been using the modified delivery approach for the last five years and we have had no complications of the technique itself. Two patients operated on by using this approach are presented. We believe that, in patients with long alar cartilages and a wide nasal tip, this modification turns the delivery approach into an easier and safer approach.
Application of winglets and/or wing tip extensions with active load control on the Boeing 747
NASA Technical Reports Server (NTRS)
Allison, R. L.; Perkin, B. R.; Schoenman, R. L.
1978-01-01
The application of wing tip modifications and active control technology to the Boeing 747 airplane for the purpose of improving fuel efficiency is considered. Wing tip extensions, wing tip winglets, and the use of the outboard ailerons for active wing load alleviation are described. Modest performance improvements are indicated. A costs versus benefits approach is taken to decide which, if any, of the concepts warrant further development and flight test leading to possible incorporation into production airplanes.
Techniques of adrenal venous sampling in patients with inferior vena cava or renal vein anomalies.
Endo, Kenji; Morita, Satoru; Suzaki, Shingo; Yamazaki, Hiroshi; Nishina, Yu; Sakai, Shuji
2018-06-01
To review the techniques and technical success rate of adrenal venous sampling (AVS) in patients with inferior vena cava (IVC) or renal vein anomalies. The techniques and success rate of AVS in 15 patients with anomalies [8 with double IVC (dIVC), 3 with left IVC (ltIVC), 2 with retroaortic left renal vein (LRV), and 2 with circumaortic LRV] underwent AVS was retrospectively reviewed. Among 11 patients with IVC anomalies, the success rates for sampling the right and left adrenal veins (RAV and LAV) were 81.8 and 90.9%, respectively. In dIVC, the LAV was selected using the following four methods: approaching through the right IVC from the right femoral vein, flipping the LAV catheter tip in the LRV (n = 4) or the interiliac-communicating vein (n = 1), or through the ltIVC from the right (n = 1) or left (n = 2) femoral vein. Among the four patients with LRV anomalies, the success rate was 100% for each adrenal vein. AVS can be successfully performed in patients with anomalies. The key to technical success is understanding the venous anatomy based on pre-procedural CT images and choosing appropriate methods.
Summary of the Large Civil Tiltrotor (LCTR2) Engine Gearbox Study
NASA Technical Reports Server (NTRS)
Snyder, Christopher A.; Robuck, Mark; Wilkerson, Joseph; Nordstrom, Carl
2010-01-01
In support of the Fundamental Aeronautics Program, Subsonic Rotary Wing Project, NASA is continuing to study the Large Civil Tiltrotor (LCTR) concept to help define/refine vehicle, system and subsystem attributes. These attributes can then be used to define performance requirements and identify new or advanced technologies to achieve an operational vehicle class. As part of this goal, NASA contracted with The Boeing Company and its subcontractor Rolls-Royce to perform an investigation of different combinations of engine and gearbox variability to achieve a maximum of 50 percent rotor tip speed reduction from hover to cruise conditions. Previous NASA studies identified the 50 percent rotor speed reduction minimized vehicle gross weight and fuel burn. The LCTR2 (LCTR-iteration 2) was the contracted study baseline for initial sizing. Rotor tip speed ratios (cruise to hover) of 100, 77, and 54 percent were analyzed for each combination of engine and gearbox speed reduction to achieve the chosen rotor tip speed ratio. Three different engine and gearbox technology levels were assumed; commercial off-the-shelf (COTS), entry-in-service (EIS) in 2025 and EIS in 2035. These technology levels were applied to determine each particular effect on vehicle gross weight and fuel burn, while other vehicle technologies were assumed constant. This report summarizes the work performed that is being put together into a comprehensive NASA contractor report. Some background on the LCTR concept and baseline vehicle will be given and then a discussion concerning the technical approach utilized. Major study assumptions and results will be presented and discussed. Finally conclusions will be drawn as well as suggestions provided for future efforts.
Lin, Chun-Ting; Chen, Yu-Wei; Su, James; Wu, Chien-Ting; Hsiao, Chien-Nan; Shiao, Ming-Hua; Chang, Mao-Nan
2015-12-01
In this study, we propose an ultra-facile approach to prepare a platinum silicide nanoparticle-modified tip apex (PSM tip) used for scanning Kelvin probe microscopy (SKPM). We combined a localized fluoride-assisted galvanic replacement reaction (LFAGRR) and atmospheric microwave annealing (AMA) to deposit a single platinum silicide nanoparticle with a diameter of 32 nm on the apex of a bare silicon tip of atomic force microscopy (AFM). The total process was completed in an ambient environment in less than 3 min. The improved potential resolution in the SKPM measurement was verified. Moreover, the resolution of the topography is comparable to that of a bare silicon tip. In addition, the negative charges found on the PSM tips suggest the possibility of exploring the use of current PSM tips to sense electric fields more precisely. The ultra-fast and cost-effective preparation of the PSM tips provides a new direction for the preparation of functional tips for scanning probe microscopy.
Educating Policymakers: 2006 NPS Arms Educators
ERIC Educational Resources Information Center
Techniques: Connecting Education and Careers, 2006
2006-01-01
This article reports that at the 2006 ACTE National Policy Seminar, nearly 500 career and technical educators gathered in Washington, DC, in March to learn about what is happening with Perkins, receive tips on working with the media, and voice their opinions with their federal representatives. Attendees left this session armed with the statistics…
Laparoscopic repair of perforated peptic ulcer-technical tip.
Jayanthi, Naga Venkatesh Gupta
2013-08-01
Increasing number of gastrointestinal emergencies are managed laparoscopically. Laparoscopic repair of a perforated peptic ulcer remains contentious. Fashioning an omental patch is a crucial and an essential part of this repair, whether it is performed open or laparoscopically. This article describes a technique to fashion an adequate omental patch over the perforated peptic ulcer.
Patel, N H; Sasadeusz, K J; Seshadri, R; Chalasani, N; Shah, H; Johnson, M S; Namyslowski, J; Moresco, K P; Trerotola, S O
2001-11-01
To determine (i) whether there is a significant increase in hepatic artery blood flow (HABF) after transjugular intrahepatic portosystemic shunt (TIPS) creation and (ii) whether the extent of incremental increase in HABF is predictive of clinical outcome after TIPS creation. Prospective, nonrandomized, nonblinded duplex Doppler ultrasound (US) examinations were performed on 24 consecutive patients (19 men; Child Class A/B/C: 4/12/8, respectively) with a mean age of 52.8 years who were referred for TIPS creation for variceal bleeding. Peak hepatic artery velocity and vessel dimensions were used to calculate the hepatic arterial blood flow (HABF) before and after TIPS creation. Patients were clinically followed in the gastrohepatology clinic and TIPS US surveillance was performed at 1 and 3 months to assess shunt function. The extent of incremental increase in HABF was analyzed as a predictor of post-TIPS encephalopathy and/or death. The technical success rate of TIPS creation was 100%. The shunt diameters were either 10 mm (n = 11) or 12 mm (n = 13). TIPS resulted in a significant reduction in the portosystemic gradient from 24.3 mm Hg +/- 5.7 to 9.3 mm Hg +/- 2.9 (P <.001). The hepatic artery peak systolic velocity and HABF increased significantly after TIPS creation, from 60.8 cm/sec +/- 26.7 to 121 cm/sec +/- 51.5 (P <.001) and from 254.2 mL/min +/- 142.2 to 507.8 mL/min +/- 261.3 (P <.001), respectively. The average incremental increase in HABF from pre-TIPS to post-TIPS was 253.6 mL/min +/- 174.2 and the average decremental decrease in portosystemic gradient was 15.0 mm Hg +/- 5.3, but there was no significant correlation (r = 0.04; P =.86) between the two. All shunts were patent at 30 and 90 days without sonographic evidence of shunt dysfunction. After TIPS creation, new or worsened encephalopathy developed in five patients at 30 days and in an additional three at 90 days. They were all successfully managed medically. Three patients (12.5%) died within 30 days of the TIPS procedure. The extent of incremental increase in HABF after TIPS was variable and did not correlate with the development of 30-day and 90-day encephalopathy (P =.41 and P =.83, respectively) or 30-day mortality (P =.2). HABF increases significantly after TIPS but is not predictive of clinical outcome. The significance of the incremental increase is yet to be determined.
Minaga, Kosuke; Kitano, Masayuki; Itonaga, Masahiro; Imai, Hajime; Miyata, Takeshi; Yamao, Kentaro; Tamura, Takashi; Nuta, Junya; Warigaya, Kenji; Kudo, Masatoshi
2017-12-08
This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.
High Temperature Investigations into an Active Turbine Blade Tip Clearance Control Concept
NASA Technical Reports Server (NTRS)
Taylor, Shawn; Steinetz, Bruce M.; Oswald, Jay J.
2007-01-01
System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA s Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.
High Temperature Investigations into an Active Turbine Blade Tip Clearance Control Concept
NASA Technical Reports Server (NTRS)
Taylor, Shawn C.; Steinetz, Bruce; Oswald, Jay J.
2008-01-01
System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA s Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.
Impact of the Tips From Former Smokers Campaign on Population-Level Smoking Cessation, 2012–2015
Davis, Kevin C.; Beistle, Diane; King, Brian A.; Duke, Jennifer; Rodes, Robert; Graffunder, Corinne
2018-01-01
This study provides estimates of the long-term cumulative impact of the Centers for Disease Control and Prevention’s national tobacco education campaign, Tips From Former Smokers (Tips), on population-level smoking cessation. We used recently published estimates of the association between increased Tips campaign media doses and quit attempts to calculate campaign-attributable population sustained (6-month) quits during 2012–2015. Tips led to approximately 522,000 sustained quits during 2012–2015. These findings indicate that the Tips campaign’s comprehensive approach to combining evidence-based messages with the promotion of cessation resources was successful in achieving substantial long-term cigarette cessation at the population level over multiple years. PMID:29862960
Jung, Goo-Eun; Noh, Hanaul; Shin, Yong Kyun; Kahng, Se-Jong; Baik, Ku Youn; Kim, Hong-Bae; Cho, Nam-Joon; Cho, Sang-Joon
2015-07-07
Scanning ion conductance microscopy (SICM) is an increasingly useful nanotechnology tool for non-contact, high resolution imaging of live biological specimens such as cellular membranes. In particular, approach-retract-scanning (ARS) mode enables fast probing of delicate biological structures by rapid and repeated approach/retraction of a nano-pipette tip. For optimal performance, accurate control of the tip position is a critical issue. Herein, we present a novel closed-loop control strategy for the ARS mode that achieves higher operating speeds with increased stability. The algorithm differs from that of most conventional (i.e., constant velocity) approach schemes as it includes a deceleration phase near the sample surface, which is intended to minimize the possibility of contact with the surface. Analysis of the ion current and tip position demonstrates that the new mode is able to operate at approach speeds of up to 250 μm s(-1). As a result of the improved stability, SICM imaging with the new approach scheme enables significantly improved, high resolution imaging of subtle features of fixed and live cells (e.g., filamentous structures & membrane edges). Taken together, the results suggest that optimization of the tip approach speed can substantially improve SICM imaging performance, further enabling SICM to become widely adopted as a general and versatile research tool for biological studies at the nanoscale level.
Customized atomic force microscopy probe by focused-ion-beam-assisted tip transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Andrew; Butte, Manish J., E-mail: manish.butte@stanford.edu
2014-08-04
We present a technique for transferring separately fabricated tips onto tipless atomic force microscopy (AFM) cantilevers, performed using focused ion beam-assisted nanomanipulation. This method addresses the need in scanning probe microscopy for certain tip geometries that cannot be achieved by conventional lithography. For example, in probing complex layered materials or tall biological cells using AFM, a tall tip with a high-aspect-ratio is required to avoid artifacts caused by collisions of the tip's sides with the material being probed. We show experimentally that tall (18 μm) cantilever tips fabricated by this approach reduce squeeze-film damping, which fits predictions from hydrodynamic theory, andmore » results in an increased quality factor (Q) of the fundamental flexural mode. We demonstrate that a customized tip's well-defined geometry, tall tip height, and aspect ratio enable improved measurement of elastic moduli by allowing access to low-laying portions of tall cells (T lymphocytes). This technique can be generally used to attach tips to any micromechanical device when conventional lithography of tips cannot be accomplished.« less
Kalman filter-based EM-optical sensor fusion for needle deflection estimation.
Jiang, Baichuan; Gao, Wenpeng; Kacher, Daniel; Nevo, Erez; Fetics, Barry; Lee, Thomas C; Jayender, Jagadeesan
2018-04-01
In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle's tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects. In this paper, measurements data from an optical sensor at the needle base and a magnetic resonance (MR) gradient field-driven electromagnetic (EM) sensor placed 10 cm from the needle tip are used within a model-integrated Kalman filter-based sensor fusion scheme. Bending model-based estimations and EM-based direct estimation are used as the measurement vectors in the Kalman filter, thus establishing an online estimation approach. Static tip bending experiments show that the fusion method can reduce the mean error of the tip position estimation from 29.23 mm of the optical sensor-based approach to 3.15 mm of the fusion-based approach and from 39.96 to 6.90 mm, at the MRI isocenter and the MRI entrance, respectively. This work established a novel sensor fusion scheme that incorporates model information, which enables real-time tracking of needle deflection with MRI compatibility, in a free-hand operating setup.
A policy hackathon for analysing impacts and solutions up to 20 metres sea-level rise
NASA Astrophysics Data System (ADS)
Haasnoot, Marjolijn; Bouwer, Laurens; Kwadijk, Jaap
2017-04-01
We organised a policy hackathon in order to quantify the impacts accelerated and high-end sea-level rise up to 20 metres on the coast of the Netherlands, and develop possible solutions. This was done during one day, with 20 experts that had a wide variety of disciplines, including hydrology, geology, coastal engineering, economics, and public policy. During the process the problem was divided up into several sub-sets of issues that were analysed and solved within small teams of between 4 to 8 people. Both a top-down impact analysis and bottom-up vulnerability analysis was done by answering the questions: What is the impact of sea level rise of x meter?; and How much sea level rise can be accommodated with before transformative actions are needed? Next, adaptation tipping points were identified that describe conditions under which the coastal system starts to perform unacceptably. Reasons for an adaptation tipping point can be technical (technically not possible), economic (cost-benefits are negative), or resources (available space, sand, energy production, financial). The results are presented in a summary document, and through an infographic displaying different adaptation tipping points and milestones that occur when the sea level rises up to 20 m. No technical limitations were found for adaptation, but many important decisions need to be taken. Although accelerated sea level rise seems far away it can have important consequences for short-term decisions that are required for transformative actions. Such extensive actions require more time for implementation. Also, other action may become ineffective before their design life. This hackathon exercise shows that it is possible to map within a short time frame the issues at hand, as well as potentially effective solutions. This can be replicated for other problems, and can be useful for several decision-makers that require quick but in-depth analysis of their long-term planning problems.
Senturk, Cagin
2015-12-01
We report a case where migrated Onyx could be removed safely with a mechanical thrombectomy device after withdrawal of the damaged microcatheter. A microcatheter was retained in the superior cerebellar artery with attached Onyx fragments on its tip during embolization of a bled cerebellar AVM. During retrieval maneuvers microcatheter shaft was ruptured and Onyx fragments were released into the vertebrobasilar system causing occlusion. Finally, Onyx fragment on tip of the microcatheter could be detached with dimethyl sulfoxide injection and the microcatheter could be withdrawn. A Merci retriever device (Concentric Medical, Mountain View, CA, USA) was successfully used to retrieve most of the dislodged Onyx material and recanalize the vertebrobasilar circulation.
Comparison of Various Supersonic Turbine Tip Designs to Minimize Aerodynamic Loss and Tip Heating
NASA Technical Reports Server (NTRS)
Shyam, Vikram; Ameri, Ali
2012-01-01
The rotor tips of axial turbines experience high heat flux and are the cause of aerodynamic losses due to tip clearance flows, and in the case of supersonic tips, shocks. As stage loadings increase, the flow in the tip gap approaches and exceeds sonic conditions. This introduces effects such as shock-boundary layer interactions and choked flow that are not observed for subsonic tip flows that have been studied extensively in literature. This work simulates the tip clearance flow for a flat tip, a diverging tip gap and several contoured tips to assess the possibility of minimizing tip heat flux while maintaining a constant massflow from the pressure side to the suction side of the rotor, through the tip clearance. The Computational Fluid Dynamics (CFD) code GlennHT was used for the simulations. Due to the strong favorable pressure gradients the simulations assumed laminar conditions in the tip gap. The nominal tip gap width to height ratio for this study is 6.0. The Reynolds number of the flow is 2.4 x 10(exp 5) based on nominal tip width and exit velocity. A wavy wall design was found to reduce heat flux by 5 percent but suffered from an additional 6 percent in aerodynamic loss coefficient. Conventional tip recesses are found to perform far worse than a flat tip due to severe shock heating. Overall, the baseline flat tip was the second best performer. A diverging converging tip gap with a hole was found to be the best choice. Average tip heat flux was reduced by 37 percent and aerodynamic losses were cut by over 6 percent.
NASA Technical Reports Server (NTRS)
Bune, Andris V.; Kaukler, William F.; Whitaker, Ann F. (Technical Monitor)
2001-01-01
Modeling approach to simulate both mesoscale and microscopic forces acting in a typical AFM experiment is presented. At mesoscale level interaction between the cantilever tip and the sample surface is primarily described by the balance of attractive Van der Waals and repulsive forces. The model of cantilever oscillations is applicable to both non-contact and "tapping" AFM. This model can be farther enhanced to describe nanoparticle manipulation by cantilever. At microscopic level tip contamination and details of tip-surface interaction can be simulated using molecular dynamics approach. Integration of mesoscale model with molecular dynamic model is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Jonathan K., E-mail: jonathan.park09@gmail.com; Al-Tariq, Quazi Z., E-mail: qat200@gmail.com; Zaw, Taryar M., E-mail: taryar.zaw@gmail.com
PurposeTo assess radiofrequency (RF) ablation efficacy, as well as the patency of transjugular intrahepatic portosystemic shunts (TIPSs), in patients with hepatocellular carcinoma (HCC).Materials and MethodsRetrospective database review of patients with pre-existing TIPS undergoing RF ablation of HCC was conducted over a 159-month period ending in November 2013. TIPS patency pre- and post-RF ablation was assessed by ultrasound, angiography, and/or contrast-enhanced CT or MRI. Patient demographics and immediate post-RF ablation outcomes and complications were also reviewed.Results19 patients with 21 lesions undergoing 25 RF ablation sessions were included. Child-Pugh class A, B, and C scores were seen in 1, 13, and 5more » patients, respectively. Eleven patients (58 %) ultimately underwent liver transplantation. Immediate technical success was seen in all ablation sessions without residual tumor enhancement (100 %). No patients (0 %) suffered liver failure within 1 month of ablation. Pre-ablation TIPS patency was demonstrated in 22/25 sessions (88 %). Of 22 cases with patent TIPS prior to ablation, post-ablation patency was demonstrated in 22/22 (100 %) at immediate post-ablation imaging and in 21/22 (95 %) at last follow-up (1 patient was incidentally noted to have occlusion 31 months later). No immediate complications were observed.ConclusionAblation efficacy was similar to the cited literature values for patients without TIPS. Furthermore, TIPS patency was preserved in the majority of cases. Patients with both portal hypertension and HCC are not uncommonly encountered, and a pre-existing TIPS does not appear to be a definite contraindication for RF ablation.« less
Writing for Profit: A Catalog of Hints.
ERIC Educational Resources Information Center
Barnum, Carol M.
1981-01-01
Offers tips to business communication teachers on how to write for money. Tips include: (1) Begin by writing for free, (2) use business contacts, (3) vary approaches to writing, and (4) write about personal experiences. (FL)
Kavrut Ozturk, Nilgun; Kavakli, Ali Sait
2017-08-01
This prospective randomized study compared the coracoid and retroclavicular approaches to ultrasound-guided infraclavicular brachial plexus block (IBPB) in terms of needle tip and shaft visibility and quality of block. We hypothesized that the retroclavicular approach would increase needle tip and shaft visibility and decrease the number of needle passes compared to the coracoid approach. A total of 100 adult patients who received IBPB block for upper limb surgery were randomized into two groups: a coracoid approach group (group C) and a retroclavicular approach group (group R). In group C, the needle was inserted 2 cm medial and 2 cm inferior to the coracoid process and directed from ventral to dorsal. In group R, the needle insertion point was posterior to the clavicle and the needle was advanced from cephalad to caudal. All ultrasound images were digitally stored for analysis. The primary aim of the present study was to compare needle tip and shaft visibility between the coracoid approach and retroclavicular approach in patients undergoing upper limb surgery. The secondary aim was to investigate differences between the two groups in the number of needle passes, sensory and motor block success rates, surgical success rate, block performance time, block performance-related pain, patient satisfaction, use of supplemental local anesthetic and analgesic, and complications. Needle tip visibility and needle shaft visibility were significantly better in group R (p = 0.040, p = 0.032, respectively). Block performance time and anesthesia-related time were significantly shorter in group R (p = 0.022, p = 0.038, respectively). Number of needle passes was significantly lower in group R (p = 0.044). Paresthesia during block performance was significantly higher in group C (p = 0.045). There were no statistically significant differences between the two groups in terms of sensory or motor block success, surgical success, block-related pain, and patient satisfaction. The retroclavicular approach is associated with better needle tip and shaft visibility, reduced performance time and anesthesia-related time, less paresthesia during block performance, and fewer needle passes than the coracoid approach. TRıAL REGISTRY NUMBER: Clinicaltrials.gov (no. NCT02673086).
Onyx embolization with the Apollo detachable tip microcatheter: A single-center experience.
Miller, Timothy R; Giacon, Luciano; Kole, Matthew J; Chen, Rong; Jindal, Gaurav; Gandhi, Dheeraj
2018-06-01
Purpose The Apollo Onyx Delivery Microcatheter (Ev3, Irvine, CA) is a detachable-tip microcatheter that was developed to reduce the risk of microcatheter entrapment during ethylene-vinyl alcohol copolymer (Onyx) embolizations. We report our experience with the microcatheter in a variety of neurointerventional procedures. Methods We retrospectively reviewed all Onyx embolizations performed in the head, neck, and spine using the Apollo Onyx Delivery Microcatheter from its introduction at our institution in July 2014 to August 2016. Information regarding patient diagnoses, procedural details, as well as clinical outcomes were obtained from the electronic medical record, procedure reports, and relevant angiographic imaging. Results A total of 58 arterial pedicle Onyx embolizations were performed in 37 patients. There were no cases of microcatheter entrapment, early/inadvertent tip detachment, or vessel injury upon removal of the device. There were two instances (3.5%) of leakage of Onyx from the microcatheter detachment site during embolization, which did not result in adverse sequelae. Clinical outcomes were excellent, with nearly all embolizations achieving the intended goal. In multivariate analysis, length of Onyx reflux along the microcatheter tip and utilization of a higher viscosity agent, Onyx 34, were significantly associated with tip detachment. Conclusion The use of the Apollo Microcatheter is both safe and effective during neurointerventional embolizations using Onyx. Leakage of liquid embolic agent from the detachment site is an infrequent technical complication that may be encountered with the device.
Employing Tip-Edge brackets on canines to simplify straight-wire mechanics.
Rocke, R T
1994-10-01
The straight-wire appliance was developed in part to reduce wire bending and therefore make treatment results more predictable. Because tip prescription is built into the bracket slots, teeth are held at their final crown angulations throughout treatment. Straight-wire brackets are used in an attempt to produce bodily tooth movement. However, teeth tend to tip when a force is applied. This tipping, especially when canines are retracted, can deflect the arch wire causing supereruption of the incisors with a resultant increase in anterior overbite and an open bite in the canine/premolar area. Placing Tip-Edge brackets (TP Orthodontics, Inc., LaPorte, Ind.) on canines and employing tipping and uprighting mechanics on these teeth can overcome these problems. Two cases are presented to illustrate this approach to treatment.
NASA Astrophysics Data System (ADS)
Patil, Jyoti V.; Mali, Sawanta S.; Kamble, Archana S.; Hong, Chang K.; Kim, Jin H.; Patil, Pramod S.
2017-11-01
One dimensional (1D) metal oxide nanostructures (1D-MONS) play a key role in the development of functional devices including energy conversion, energy storage and environmental devices. They are also used for some important biomedical products like wound dressings, filter media, drug delivery and tissue engineering. The electrospinning (ES) is the versatile technique for making of 1D growth of nanostructured nanofibers, an experimental approach and its applications. The present review is focused on the 1D growth of nanostructured nanofibers in different applications like dye sensitized solar cells, perovskite solar cells, fuel cells, lithium ion batteries, redox flow batteries, supercapacitor, photocatalytic, and gas sensors based on ZnO, TiO2, MnO2, WO3, V2O5, NiO, SnO2, Fe2O3 etc. metal oxides, their composites and carbon. This review article presents an introduction to various types of ES techniques and their technical details. Also, the advantages and disadvantages of each ES technique are summarized. The various technical details such as preparative parameters, post-deposition methods, applied electric field, solution feed rate and a distance between a tip to the collector are the key factors in order to obtain exotic 1D nanostructured materials. Also, the lucid literature survey on the growth of nanostructures of various metal oxides and application in different fields are covered in this review. Further, the future perspectives has also been discussed.
Low power femtosecond tip-based nanofabrication with advanced control
NASA Astrophysics Data System (ADS)
Liu, Jiangbo; Guo, Zhixiong; Zou, Qingze
2018-02-01
In this paper, we propose an approach to enable the use of low power femtosecond laser in tip-based nanofabrication (TBN) without thermal damage. One major challenge in laser-assisted TBN is in maintaining precision control of the tip-surface positioning throughout the fabrication process. An advanced iterative learning control technique is exploited to overcome this challenge in achieving high-quality patterning of arbitrary shape on a metal surface. The experimental results are analyzed to understand the ablation mechanism involved. Specifically, the near-field radiation enhancement is examined via the surface-enhanced Raman scattering effect, and it was revealed the near-field enhanced plasma-mediated ablation. Moreover, silicon nitride tip is utilized to alleviate the adverse thermal damage. Experiment results including line patterns fabricated under different writing speeds and an "R" pattern are presented. The fabrication quality with regard to the line width, depth, and uniformity is characterized to demonstrate the efficacy of the proposed approach.
NASA Astrophysics Data System (ADS)
Nguyen-Thanh, Nhon; Li, Weidong; Zhou, Kun
2018-03-01
This paper develops a coupling approach which integrates the meshfree method and isogeometric analysis (IGA) for static and free-vibration analyses of cracks in thin-shell structures. In this approach, the domain surrounding the cracks is represented by the meshfree method while the rest domain is meshed by IGA. The present approach is capable of preserving geometry exactness and high continuity of IGA. The local refinement is achieved by adding the nodes along the background cells in the meshfree domain. Moreover, the equivalent domain integral technique for three-dimensional problems is derived from the additional Kirchhoff-Love theory to compute the J-integral for the thin-shell model. The proposed approach is able to address the problems involving through-the-thickness cracks without using additional rotational degrees of freedom, which facilitates the enrichment strategy for crack tips. The crack tip enrichment effects and the stress distribution and displacements around the crack tips are investigated. Free vibrations of cracks in thin shells are also analyzed. Numerical examples are presented to demonstrate the accuracy and computational efficiency of the coupling approach.
Troubleshooting Microcomputers. A Technical Guide for Polk County Schools.
ERIC Educational Resources Information Center
Black, B. R.; And Others
This guide was started in 1986 as an effort to pull together a collection of several computer guides that had been written over the previous several years to assist schools in making simple computer repairs. The first of six sections contains general tips and hints, including sections on tool requirements, strobe disk speed adjustment, static…
For the Article Writer...How to Win Acceptances by Psychology Journals: 21 Tips for Better Writing.
ERIC Educational Resources Information Center
Sternberg, Robert J.
1993-01-01
Twenty-one suggestions are offered for successful writing for psychology journals. Suggestions include tell readers why they should be interested, consider alternative interpretations of the data, give concrete examples, write for a somewhat broader and technically less skilled audience than you expect to read the article, and don't take…
ERIC Educational Resources Information Center
North American Association for Environmental Education, Troy, OH.
This collection gathers together over 50 high-quality materials to support environmental education (EE) curricula. Because each community has unique environmental and educational needs, the guide includes a broad set of educational materials that can be adapted to a variety of settings. The materials can be used to supplement educational…
Restaurant Role-Play in Psychology
ERIC Educational Resources Information Center
Borya, Anthony
2013-01-01
Research methods is perceived as a technical and difficult topic by some students. Using role-play to teach it can make it more accessible, meaningful and engaging. Role-playing the familiar roles of customer and waiting staff at a restaurant and discussing the variables that may affect the size of tips can help students to learn some of the key…
A scanning tunneling microscope capable of imaging specified micron-scale small samples.
Tao, Wei; Cao, Yufei; Wang, Huafeng; Wang, Kaiyou; Lu, Qingyou
2012-12-01
We present a home-built scanning tunneling microscope (STM) which allows us to precisely position the tip on any specified small sample or sample feature of micron scale. The core structure is a stand-alone soft junction mechanical loop (SJML), in which a small piezoelectric tube scanner is mounted on a sliding piece and a "U"-like soft spring strip has its one end fixed to the sliding piece and its opposite end holding the tip pointing to the sample on the scanner. Here, the tip can be precisely aligned to a specified small sample of micron scale by adjusting the position of the spring-clamped sample on the scanner in the field of view of an optical microscope. The aligned SJML can be transferred to a piezoelectric inertial motor for coarse approach, during which the U-spring is pushed towards the sample, causing the tip to approach the pre-aligned small sample. We have successfully approached a hand cut tip that was made from 0.1 mm thin Pt∕Ir wire to an isolated individual 32.5 × 32.5 μm(2) graphite flake. Good atomic resolution images and high quality tunneling current spectra for that specified tiny flake are obtained in ambient conditions with high repeatability within one month showing high and long term stability of the new STM structure. In addition, frequency spectra of the tunneling current signals do not show outstanding tip mount related resonant frequency (low frequency), which further confirms the stability of the STM structure.
Wang, Yuliang; Wang, Huimin; Bi, Shusheng; Guo, Bin
2016-01-01
The dynamic wetting properties of atomic force microscopy (AFM) tips are of much concern in many AFM-related measurement, fabrication, and manipulation applications. In this study, the wetting properties of silicon and silicon nitride AFM tips are investigated through dynamic contact angle measurement using a nano-Wilhelmy balance based method. This is done by capillary force measurement during extension and retraction motion of AFM tips relative to interfacial nanobubbles. The working principle of the proposed method and mathematic models for dynamic contact angle measurement are presented. Geometric models of AFM tips were constructed using scanning electronic microscopy (SEM) images taken from different view directions. The detailed process of tip-nanobubble interaction was investigated using force-distance curves of AFM on nanobubbles. Several parameters including nanobubble height, adhesion and capillary force between tip and nanobubbles are extracted. The variation of these parameters was studied over nanobubble surfaces. The dynamic contact angles of the AFM tips were calculated from the capillary force measurements. The proposed method provides direct measurement of dynamic contact angles for AFM tips and can also be taken as a general approach for nanoscale dynamic wetting property investigation. PMID:27452115
NASA Astrophysics Data System (ADS)
Wang, Yuliang; Wang, Huimin; Bi, Shusheng; Guo, Bin
2016-07-01
The dynamic wetting properties of atomic force microscopy (AFM) tips are of much concern in many AFM-related measurement, fabrication, and manipulation applications. In this study, the wetting properties of silicon and silicon nitride AFM tips are investigated through dynamic contact angle measurement using a nano-Wilhelmy balance based method. This is done by capillary force measurement during extension and retraction motion of AFM tips relative to interfacial nanobubbles. The working principle of the proposed method and mathematic models for dynamic contact angle measurement are presented. Geometric models of AFM tips were constructed using scanning electronic microscopy (SEM) images taken from different view directions. The detailed process of tip-nanobubble interaction was investigated using force-distance curves of AFM on nanobubbles. Several parameters including nanobubble height, adhesion and capillary force between tip and nanobubbles are extracted. The variation of these parameters was studied over nanobubble surfaces. The dynamic contact angles of the AFM tips were calculated from the capillary force measurements. The proposed method provides direct measurement of dynamic contact angles for AFM tips and can also be taken as a general approach for nanoscale dynamic wetting property investigation.
You, H-J; Moon, K-C; Yoon, E-S; Lee, B-I; Park, S-H
2016-03-01
Fractures of the mandibular condyle are one of the most common craniofacial fractures. However, the diagnosis and treatment of these fractures is controversial because of the multiple surgical approaches available. The purposes of this study were to identify surgery-related technical tips for better outcomes and to evaluate the results as well as complications encountered during 7 years of endoscope use to supplement the limited intraoral approach in the treatment of mandibular condylar fractures. Between 2005 and 2012, 50 patients with condylar fractures underwent endoscope-assisted reduction surgery. Postoperative facial bone computed tomography and panoramic radiography demonstrated adequate reduction of the condylar fractures in all patients. No condylar resorption was detected, and most patients displayed a satisfactory functional and structural recovery. There was no facial nerve damage or transitory hypoesthesia, and there were no visible scars after the surgery. Transoral endoscope-assisted treatment is a challenging but reliable method with lower morbidity and a rapid recovery. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Computer-assisted neurosurgical navigational system for transsphenoidal surgery--technical note.
Onizuka, M; Tokunaga, Y; Shibayama, A; Miyazaki, H
2001-11-01
Transsphenoidal surgery carries the risk of carotid artery injury even for very experienced neurosurgeons. The computer-assisted neurosurgical (CANS) navigational system was used to obtain more precise guidance, based on the axial and coronal images during the transsphenoidal approach for nine pituitary adenomas. The CANS navigator consists of a three-dimensional digitizer, a computer, and a graphic unit, which utilizes electromagnetic coupling technology to detect the spatial position of a suction tube attached to a magnetic sensor. Preoperatively, the magnetic resonance images are transferred and stored in the computer and the tip of the suction tube is shown on a real-time basis superimposed on the preoperative images. The CANS navigation system correctly displayed the surgical orientation and provided localization in all nine patients. No intraoperative complications were associated with the use of this system. However, outflow of cerebrospinal fluid during tumor removal may affect the accuracy, so the position of the probe when the tumor is removed must be accurately determined. The CANS navigator enables precise localization of the suction tube during the transsphenoidal approach and allows safer and less-invasive surgery.
Stachowicz, Aneta; Siudut, Jakub; Suski, Maciej; Olszanecki, Rafał; Korbut, Ryszard; Undas, Anetta; Wiśniewski, Jacek R
2017-01-01
It is well known that fibrin network binds a large variety of proteins, including inhibitors and activators of fibrinolysis, which may affect clot properties, such as stability and susceptibility to fibrinolysis. Specific plasma clot composition differs between individuals and may change in disease states. However, the plasma clot proteome has not yet been in-depth analyzed, mainly due to technical difficulty related to the presence of a highly abundant protein-fibrinogen and fibrin that forms a plasma clot. The aim of our study was to optimize quantitative proteomic analysis of fibrin clots prepared ex vivo from citrated plasma of the peripheral blood drawn from patients with prior venous thromboembolism (VTE). We used a multiple enzyme digestion filter aided sample preparation, a multienzyme digestion (MED) FASP method combined with LC-MS/MS analysis performed on a Proxeon Easy-nLC System coupled to the Q Exactive HF mass spectrometer. We also evaluated the impact of peptide fractionation with pipet-tip strong anion exchange (SAX) method on the obtained results. Our proteomic approach revealed 476 proteins repeatedly identified in the plasma fibrin clots from patients with VTE including extracellular vesicle-derived proteins, lipoproteins, fibrinolysis inhibitors, and proteins involved in immune responses. The MED FASP method using three different enzymes: LysC, trypsin and chymotrypsin increased the number of identified peptides and proteins and their sequence coverage as compared to a single step digestion. Peptide fractionation with a pipet-tip strong anion exchange (SAX) protocol increased the depth of proteomic analyses, but also extended the time needed for sample analysis with LC-MS/MS. The MED FASP method combined with a label-free quantification is an excellent proteomic approach for the analysis of fibrin clots prepared ex vivo from citrated plasma of patients with prior VTE.
2004 Annual Health Physics Report for the HEU Transparency Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2005-04-01
During the 2004 calendar year, LLNL provided health physics support for the Highly Enriched Uranium Transparency Implementation Program (HEU-TIP) in external and internal radiation protection and technical expertise into matters related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2004, there were 200 person-trips that required dose monitoring of the U.S. monitors. Of the 200 person-trips, 183 person-trips were SMVs and 17 person-trips were Transparency Monitoring Office (TMO) trips. Eight person-trips from the SMV trips were continuation trips of TMO monitors to facilities other than UEIP. The LLNL Safety Laboratories' Division provided the dosimetrymore » services for the HEU-TIP monitors.« less
Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier
2017-04-01
The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Holographic studies of shock waves within transonic fan rotors
NASA Technical Reports Server (NTRS)
Benser, W. A.; Bailey, E. E.; Gelder, T. F.
1974-01-01
NASA has funded two separate contracts to apply pulsed laser holographic interferometry to the detection of shock patterns in the outer span regions of high tip speed transonic rotors. The first holographic approach used ruby laser light reflected from a portion of the centerbody just ahead of the rotor. These holograms showed the bow wave patterns upstream of the rotor and the shock patterns just inside the blade row near the tip. The second holographic approach, on a different rotor, used light transmitted diagonally across the inlet annulus past the centerbody. This approach gave a more extensive view of the region bounded by the blade leading and trailing edges, by the part span shroud and by the blade tip. These holograms showed the passage shock emanating from the blade leading edge and a moderately strong conical shock originating at the intersection of the part span shroud leading edge and the blade suction surface.
Tringali, Stéphane; Koka, Kanthaiah; Deveze, Arnaud; Holland, N. Julian; Jenkins, Herman A.; Tollin, Daniel J.
2010-01-01
Objectives To assess the importance of 2 variables, transducer tip diameter and resection of the round window (RW) niche, affecting the optimization of the mechanical stimulation of the RW membrane with an active middle ear implant (AMEI). Materials and Methods: Ten temporal bones were prepared with combined atticotomy and facial recess approach to expose the RW. An AMEI stimulated the RW with 2 ball tip diameters (0.5 and 1.0 mm) before and after the resection of the bony rim of the RW niche. The RW drive performance, assessed by stapes velocities using laser Doppler velocimetry, was analyzed in 3 frequency ranges: low (0.25–1 kHz), medium (1–3 kHz) and high (3–8 kHz). Results Driving the RW produced mean peak stapes velocities (HEV) of 0.305 and 0.255 mm/s/V at 3.03 kHz, respectively, for the 1- and 0.5-mm tips, with the RW niche intact. Niche drilling increased the HEV to 0.73 and 0.832 mm/s/V for the 1- and 0.5-mm tips, respectively. The tip diameter produced no difference in output at low and medium frequencies; however, the 0.5-mm tip was 5 and 6 dB better than the 1-mm tip at high frequencies before and after niche drilling, respectively. Drilling the niche significantly improved the output by 4 dB at high frequencies for the 1-mm tip, and by 6 and 10 dB in the medium- and high-frequency ranges for the 0.5-mm tip. Conclusion The AMEI was able to successfully drive the RW membrane in cadaveric temporal bones using a classical facial recess approach. Stimulation of the RW membrane with an AMEI without drilling the niche is sufficient for successful hearing outputs. However, the resection of the bony rim of the RW niche significantly improved the RW stimulation at medium and higher frequencies. Drilling the niche enhances the exposure of the RW membrane and facilitates positioning the implant tip. PMID:20150727
Inventive Performance Improvement of Integrated Optical Rate Sensor Using TIPS/TRIZ
NASA Technical Reports Server (NTRS)
Blosiu, Julian O.; Youmans, Bruce R.; Kowalick, Jim
1996-01-01
The Theory of Inventive Problem Solving (TIPS or also known as TRIZ) is a new scientific approach to innovative improvements of products and processes. This methodology was applied to inventively improve performance of an Integrated Optic Rate Sensor (IORS).
Investigation on tip enhanced Raman spectra of graphene
NASA Astrophysics Data System (ADS)
Li, Xinjuan; Liu, Yanqi; Zeng, Zhuo; Wang, Peijie; Fang, Yan; Zhang, Lisheng
2018-02-01
Tip-enhanced Raman scattering (TERS) is a promising analytical approach for some two-dimensional materials and offers the possibility to correlate imaging and chemical data. Tip-enhanced Raman spectra of graphene are discussed in some details, including substrate, gap between tip-apex and sample surface as well as Ag-nanowire. The TERS spectra give special emphasis to the possibility of TERS tip to induce a large number of defects only while got the tip attached to sample surface. Then the dependence of the TERS spectra of graphene and gap between the probe tip and sample surface was studied, and distribution features of electromagnetic (EM) field around tip were also simulated by finite-difference time-domain (FDTD). The Raman signal enhancement of graphene was further discussed with respect to experimental data. Furthermore, the Ag-nanowire as a nano-antenna could significantly enhance the weak Raman signal of D-band of monolayer graphene is shown, and the TERS spectra of graphene with regard to different regions of Ag-nanowires (endpoints, body) were obtained toward investigating into the distribution of electromagnetic field.
Identification of tipping elements of the Indian Summer Monsoon using climate network approach
NASA Astrophysics Data System (ADS)
Stolbova, Veronika; Surovyatkina, Elena; Kurths, Jurgen
2015-04-01
Spatial and temporal variability of the rainfall is a vital question for more than one billion of people inhabiting the Indian subcontinent. Indian Summer Monsoon (ISM) rainfall is crucial for India's economy, social welfare, and environment and large efforts are being put into predicting the Indian Summer Monsoon. For predictability of the ISM, it is crucial to identify tipping elements - regions over the Indian subcontinent which play a key role in the spatial organization of the Indian monsoon system. Here, we use climate network approach for identification of such tipping elements of the ISM. First, we build climate networks of the extreme rainfall, surface air temperature and pressure over the Indian subcontinent for pre-monsoon, monsoon and post-monsoon seasons. We construct network of extreme rainfall event using observational satellite data from 1998 to 2012 from the Tropical Rainfall Measuring Mission (TRMM 3B42V7) and reanalysis gridded daily rainfall data for a time period of 57 years (1951-2007) (Asian Precipitation Highly Resolved Observational Data Integration Towards the Evaluation of Water Resources, APHRODITE). For the network of surface air temperature and pressure fields, we use re-analysis data provided by the National Center for Environmental Prediction and National Center for Atmospheric Research (NCEP/NCAR). Second, we filter out data by coarse-graining the network through network measures, and identify tipping regions of the ISM. Finally, we compare obtained results of the network analysis with surface wind fields and show that occurrence of the tipping elements is mostly caused by monsoonal wind circulation, migration of the Intertropical Convergence Zone (ITCZ) and Westerlies. We conclude that climate network approach enables to select the most informative regions for the ISM, providing realistic description of the ISM dynamics with fewer data, and also help to identify tipping regions of the ISM. Obtained tipping elements deserve a special attention for the meteorologists and can be used as markers of the ISM variability.
Frégeau, Chantal J; Lett, C Marc; Elliott, Jim; Yensen, Craig; Fourney, Ron M
2008-05-01
An automated process has been developed for the analysis of forensic casework samples using TECAN Genesis RSP 150/8 or Freedom EVO liquid handling workstations equipped exclusively with nondisposable tips. Robot tip cleaning routines have been incorporated strategically within the DNA extraction process as well as at the end of each session. Alternative options were examined for cleaning the tips and different strategies were employed to verify cross-contamination. A 2% sodium hypochlorite wash (1/5th dilution of the 10.8% commercial bleach stock) proved to be the best overall approach for preventing cross-contamination of samples processed using our automated protocol. The bleach wash steps do not adversely impact the short tandem repeat (STR) profiles developed from DNA extracted robotically and allow for major cost savings through the implementation of fixed tips. We have demonstrated that robotic workstations equipped with fixed pipette tips can be used with confidence with properly designed tip washing routines to process casework samples using an adapted magnetic bead extraction protocol.
Ultrafast time-resolved photoemission of a metallic tip/substrate junction
NASA Astrophysics Data System (ADS)
Meng, Xiang; Jin, Wencan; Yang, Hao; Dadap, Jerry; Osgood, Richard; Camillone, Nicholas, III
The strong near-field enhancement of metallic-tip nanostructures has attracted great interest in scanning microscopy techniques, such as surface-enhanced Raman scattering, near-field scanning optical microscopy and tip-enhanced nonlinear imaging. In this talk, we use a full vectorial 3D-FDTD method to investigate the spatial characteristics of the optical field confinement and localization between a tungsten nanoprobe and an infinite planar silver substrate, with two-color ultrafast laser excitation scheme. The degree of two-color excited field enhancement, geometry dependence, the exact mechanism of optical tip-substrate coupling and tip-substrate plasmon resonances are significant in understanding the electrodynamical responses at tip-substrate junction. The demonstrated measurements with subpicosecond time and subnanometer spatial resolution suggest a new approach to ultrafast time-resolved measurements of surface electron dynamics. DE-FG 02-90-ER-14104; DE-FG 02-04-ER-46157.
Wettability of AFM tip influences the profile of interfacial nanobubbles
NASA Astrophysics Data System (ADS)
Teshima, Hideaki; Takahashi, Koji; Takata, Yasuyuki; Nishiyama, Takashi
2018-02-01
To accurately characterize the shape of interfacial nanobubbles using atomic force microscopy (AFM), we investigated the effect of wettability of the AFM tip while operating in the peak force tapping (PFT) mode. The AFM tips were made hydrophobic and hydrophilic by Teflon AF coating and oxygen plasma treatment, respectively. It was found that the measured base radius of nanobubbles differed between AFM height images and adhesion images, and that this difference depended on the tip wettability. The force curves obtained during the measurements were also different depending on the wettability, especially in the range of the tip/nanobubble interaction and in the magnitude of the maximum attractive force in the retraction period. The difference suggests that hydrophobic tips penetrate the gas/liquid interface of the nanobubbles, with the three phase contact line being pinned on the tip surface; hydrophilic tips on the other hand do not penetrate the interface. We then quantitatively estimated the pinning position and recalculated the true profiles of the nanobubbles by comparing the height images and adhesion images. As the AFM tip was made more hydrophilic, the penetration depth decreased and eventually approached zero. This result suggests that the PFT measurement using a hydrophilic tip is vital for the acquisition of reliable nanobubble profiles.
NASA Astrophysics Data System (ADS)
Dana, Aykutlu; Ozgur, Erol; Torunoglu, Gamze
2016-09-01
We present a dynamic approach to scanning near field optical microscopy that extends the measurement technique to the third dimension, by strobing the illumination in sync with the cantilever oscillation. Nitrogen vacancy (NV) centers in nanodiamonds placed on cantilever tips are used as stable emitters for emission enhancement. Local field enhancement and modulation of optical density states are mapped in three dimensions based on fluorescence intensity and spectrum changes as the tip is scanned over plasmonic nanostructures. The excitation of NV centers is done using a total internal reflection setup. Using a digital phase locked loop to pulse the excitation in various tip sample separations, 2D slices of fluorescence enhancement can be recorded. Alternatively, a conventional SNOM tip can be used to selectively couple wideband excitation to the collection path, with subdiffraction resolution of 60 nm in x and y and 10 nm in z directions. The approach solves the problem of tip-sample separation stabilization over extended periods of measurement time, required to collect data resolved in emission wavelength and three spatial dimensions. The method can provide a unique way of accessing the three dimensional field and mode profiles of nanophotonics structures.
NASA Astrophysics Data System (ADS)
Patil, Prataprao; Vyasarayani, C. P.; Ramji, M.
2017-06-01
In this work, digital photoelasticity technique is used to estimate the crack tip fracture parameters for different crack configurations. Conventionally, only isochromatic data surrounding the crack tip is used for SIF estimation, but with the advent of digital photoelasticity, pixel-wise availability of both isoclinic and isochromatic data could be exploited for SIF estimation in a novel way. A linear least square approach is proposed to estimate the mixed-mode crack tip fracture parameters by solving the multi-parameter stress field equation. The stress intensity factor (SIF) is extracted from those estimated fracture parameters. The isochromatic and isoclinic data around the crack tip is estimated using the ten-step phase shifting technique. To get the unwrapped data, the adaptive quality guided phase unwrapping algorithm (AQGPU) has been used. The mixed mode fracture parameters, especially SIF are estimated for specimen configurations like single edge notch (SEN), center crack and straight crack ahead of inclusion using the proposed algorithm. The experimental SIF values estimated using the proposed method are compared with analytical/finite element analysis (FEA) results, and are found to be in good agreement.
Tracking Blade Tip Vortices for Numerical Flow Simulations of Hovering Rotorcraft
NASA Technical Reports Server (NTRS)
Kao, David L.
2016-01-01
Blade tip vortices generated by a helicopter rotor blade are a major source of rotor noise and airframe vibration. This occurs when a vortex passes closely by, and interacts with, a rotor blade. The accurate prediction of Blade Vortex Interaction (BVI) continues to be a challenge for Computational Fluid Dynamics (CFD). Though considerable research has been devoted to BVI noise reduction and experimental techniques for measuring the blade tip vortices in a wind tunnel, there are only a handful of post-processing tools available for extracting vortex core lines from CFD simulation data. In order to calculate the vortex core radius, most of these tools require the user to manually select a vortex core to perform the calculation. Furthermore, none of them provide the capability to track the growth of a vortex core, which is a measure of how quickly the vortex diffuses over time. This paper introduces an automated approach for tracking the core growth of a blade tip vortex from CFD simulations of rotorcraft in hover. The proposed approach offers an effective method for the quantification and visualization of blade tip vortices in helicopter rotor wakes. Keywords: vortex core, feature extraction, CFD, numerical flow visualization
Schricker, Amir A; Feld, Gregory K; Tsimikas, Sotirios
2015-11-15
Transseptal introducer sheaths are being used with increasing frequency for left-sided arrhythmia ablations and structural heart disease interventions. Sheath tip detachment and embolization is an uncommon but known complication, and several sheaths have been recalled due to such complications. We report a unique case of a fractured transseptal sheath tip that embolized to a branch of the right pulmonary artery in a patient who had undergone ablation of a left-sided atypical atrial flutter. During final removal of one of the two long 8.5-French SL1 transseptal sheaths used routinely as part of the ablation, the radiopaque tip of the sheath fractured and first embolized to the right atrium and subsequently to a secondary right pulmonary artery branch. Using techniques derived from percutaneous interventional approaches, including a multipurpose catheter, coronary guidewire, and monorail angioplasty balloon, the sheath tip was successfully wired through its inner lumen, trapped from the inside with the balloon, and removed from the body via a large femoral vein sheath, without complications. The approach detailed in this case may guide future cases and circumvent urgent surgical intervention. © 2015 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terryn, Raymond J.; Sriraman, Krishnan; Olson, Joel A., E-mail: jolson@fit.edu
A new simulator for scanning tunneling microscopy (STM) is presented based on the linear combination of atomic orbitals molecular orbital (LCAO-MO) approximation for the effective tunneling Hamiltonian, which leads to the convolution integral when applied to the tip interaction with the sample. This approach intrinsically includes the structure of the STM tip. Through this mechanical emulation and the tip-inclusive convolution model, dI/dz images for molecular orbitals (which are closely associated with apparent barrier height, ϕ{sub ap}) are reported for the first time. For molecular adsorbates whose experimental topographic images correspond well to isolated-molecule quantum chemistry calculations, the simulator makes accuratemore » predictions, as illustrated by various cases. Distortions in these images due to the tip are shown to be in accord with those observed experimentally and predicted by other ab initio considerations of tip structure. Simulations of the tunneling current dI/dz images are in strong agreement with experiment. The theoretical framework provides a solid foundation which may be applied to LCAO cluster models of adsorbate–substrate systems, and is extendable to emulate several aspects of functional STM operation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ha, Thuong G. Van, E-mail: tgvanha@radiology.bsd.uchicago.edu; Hodge, Justin; Funaki, Brian
2006-10-15
Purpose. To determine the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) creation in patients with liver cirrhosis complicated by thrombosed portal vein. Methods. This study reviewed 15 cases of TIPS creation in 15 cirrhotic patients with portal vein thrombosis at our institution over an 8-year period. There were 2 women and 13 men with a mean age of 53 years. Indications were refractory ascites, variceal hemorrhage, and refractory pleural effusion. Clinical follow-up was performed in all patients. Results. The technical success rate was 75% (3/4) in patients with chronic portal vein thrombosis associated with cavernomatous transformation and 91%more » (10/11) in patients with acute thrombosis or partial thrombosis, giving an overall success rate of 87%. Complications included postprocedural encephalopathy and localized hematoma at the access site. In patients with successful shunt placement, the total follow-up time was 223 months. The 30-day mortality rate was 13%. Two patients underwent liver transplantation at 35 days and 7 months, respectively, after TIPS insertion. One patient had an occluded shunt at 4 months with an unsuccessful revision. The remaining patients had functioning shunts at follow-up. Conclusion. TIPS creation in thrombosed portal vein is possible and might be a treatment option in certain patients.« less
NASA Astrophysics Data System (ADS)
Milkoreit, Manjana; Hodbod, Jennifer; Baggio, Jacopo; Benessaiah, Karina; Calderón-Contreras, Rafael; Donges, Jonathan F.; Mathias, Jean-Denis; Rocha, Juan Carlos; Schoon, Michael; Werners, Saskia E.
2018-03-01
The term tipping point has experienced explosive popularity across multiple disciplines over the last decade. Research on social-ecological systems (SES) has contributed to the growth and diversity of the term’s use. The diverse uses of the term obscure potential differences between tipping behavior in natural and social systems, and issues of causality across natural and social system components in SES. This paper aims to create the foundation for a discussion within the SES research community about the appropriate use of the term tipping point, especially the relatively novel term ‘social tipping point.’ We review existing literature on tipping points and similar concepts (e.g. regime shifts, critical transitions) across all spheres of science published between 1960 and 2016 with a special focus on a recent and still small body of work on social tipping points. We combine quantitative and qualitative analyses in a bibliometric approach, rooted in an expert elicitation process. We find that the term tipping point became popular after the year 2000—long after the terms regime shift and critical transition—across all spheres of science. We identify 23 distinct features of tipping point definitions and their prevalence across disciplines, but find no clear taxonomy of discipline-specific definitions. Building on the most frequently used features, we propose definitions for tipping points in general and social tipping points in SES in particular.
Methods for Improving the Curvature of Steerable Needles in Biological Tissue
Adebar, Troy K.; Greer, Joseph D.; Laeseke, Paul F.; Hwang, Gloria L.; Okamura, Allison M.
2016-01-01
Robotic needle steering systems have the potential to improve percutaneous interventions such as radiofrequency ablation of liver tumors, but steering techniques described to date have not achieved sufficiently small radius of curvature in biological tissue to be relevant to this application. In this work, the impact of tip geometry on steerable needle curvature is examined. Finite-element simulations and experiments with bent-tip needles in ex vivo liver tissue demonstrate that selection of tip length and angle can greatly improve curvature, with radius of curvature below 5 cm in liver tissue possible through judicious selection of these parameters. Motivated by the results of this analysis, a new articulated-tip steerable needle is described, in which a distal section is actively switched by a robotic system between a straight tip (resulting in a straight path) and a bent tip (resulting in a curved path). This approach allows the tip length and angle to be increased, while the straight configuration allows the needle tip to still pass through an introducer sheath and rotate inside the body. Validation testing in liver tissue shows that the new articulated-tip steerable needle achieves smaller radius of curvature compared to bent-tip needles described in previous work. Steerable needles with optimized tip parameters, which can generate tight curves in liver tissue, increase the clinical relevance of needle steering to percutaneous interventions. PMID:26441438
NASA Astrophysics Data System (ADS)
Schwyzer, Olivier; Saenger, Nicole
2016-11-01
The Hydraulic Pressure Machine (HPM) is an energy converter to exploit head differences between 0.5 and 2.5 m in small streams and irrigation canals. Previous investigations show that efficiencies above 60% are possible. Several case studies indicate good continuity for aquatic life (e.g. fish) and bed load for the technology. The technology is described as an economically and ecologically viable option for small scale hydropower generation. Primary goal of this research is to improve the HPM blade design regarding its continuity properties by maintaining good efficiency rates. This is done by modifying the blade tip and testing within a large physical model under laboratory condition. Blade tips from steel (conventional - reference case) and a combination of EPDM rubber and steel as sandwich construction (rubber, steel, rubber - adhesive layered) are tested and compared. Both materials reach similar values for hydraulic efficiency (approx. 58%) and mechanical power output (approx. 220 W). The variation of different gap sizes pointed out the importance of small clearance gaps to reach high efficiencies. For assessing the two blade tip materials regarding continuity for aquatic life, fish dummies were led through the wheel. Analysis of slow motion video of dummies hit by the blade show significant advantages for the EPDM blade tip. The EPDM rubber allows to bend and thus reduces the shock and the probability for cuts on the fish dummy. It was shown that blade tips from EPDM have certain advantages regarding continuity compared to standard blade tips from steel. No compromise regarding energy production had to be made. These results from the HPM can be transferred to breast shot water wheel and may be applied for new and retrofitting projects.
NASA Technical Reports Server (NTRS)
Robuck, Mark; Wilkerson, Joseph; Snyder, Christopher A.; Zhang, Yiyi; Maciolek, Bob
2013-01-01
In a series of study tasks conducted as a part of NASA's Fundamental Aeronautics Program, Rotary Wing Project, Boeing and Rolls-Royce explored propulsion, drive, and rotor system options for the NASA Large Civil Tilt Rotor (LCTR2) concept vehicle. The original objective of this study was to identify engine and drive system configurations to reduce rotor tip speed during cruise conditions and quantify the associated benefits. Previous NASA studies concluded that reducing rotor speed (from 650 fps hover tip speed) during cruise would reduce vehicle gross weight and fuel burn. Initially, rotor cruise speed ratios of 54% of the hover tip speed were of most interest during operation at cruise air speed of 310 ktas. Interim results were previously reported1 for cruise tip speed ratios of 100%, 77%, and 54% of the hover tip speed using engine and/or gearbox features to achieve the reduction. Technology levels from commercial off-the-shelf (COTS), through entry-in-service (EIS) dates of 2025 and 2035 were considered to assess the benefits of advanced technology on vehicle gross weight and fuel burn. This technical paper presents the final study results in terms of vehicle sizing and fuel burn as well as Operational and Support (O&S) costs. New vehicle sizing at rotor tip speed reduced to 65% of hover is presented for engine performance with an EIS 2035 fixed geometry variable speed power turbine. LCTR2 is also evaluated for missions range cases of 400, 600, 800, 1000, and 1200 nautical miles and cruise air speeds of 310, 350 and 375 ktas.
Herial, Nabeel A; Khan, Asif A; Sherr, Gregory T; Qureshi, Mushtaq H; Suri, M Fareed K; Qureshi, Adnan I
2015-09-01
The US Food and Drug Administration recently approved a detachable-tip microcatheter, the Apollo microcatheter (eV3, Inc, Irvine, California), to prevent catheter entrapment during embolization of brain arteriovenous malformations (AVMs) using liquid embolic systems. To report technical aspects and clinical results of cerebral embolizations with the Apollo microcatheter in 7 embolizations in 3 adult patients. A 62-year-old man presented with an AVM in the parieto-occipital region measuring 3.6 × 1.6 cm with major cortical feeders from the right middle cerebral artery (MCA) and minor contribution from the distal right anterior cerebral artery. Two pedicles originating from the MCA were embolized. A 48-year-old woman presented with a left frontal AVM measuring 3.3 × 1.8 cm with arterial feeders from the left MCA, left middle meningeal artery, and contralateral anterior cerebral artery. Three pedicles originating from the left MCA were embolized. A 76-year-old man presented with an arteriovenous fistula with multiple fistulous connections and feeders from both vertebral and occipital arteries and the left posterior cerebral artery draining into the left transverse, torcula, and left sigmoid sinus. Two major occipital artery feeders were embolized. Seven Apollo microcatheters were used with the Onyx 18 liquid embolic system. The length of the detachable tip was 15 mm in 2 and 30 mm in 5 embolizations. The mean microcatheter in-position time within the pedicle was 20 minutes. Detachment of tip occurred in 3 instances. No limitations in accessing target arterial feeders and safe tip disengagement were noted despite prolonged injection times. Our initial experience supports the feasibility, safety, and effectiveness of detachable-tip microcatheters in treating brain AVMs and arteriovenous fistulas.
TAKING IT TO THE PEWS: A CBPR-GUIDED HIV AWARENESS AND SCREENING PROJECT WITH BLACK CHURCHES
Berkley-Patton, Jannette; Bowe-Thompson, Carole; Bradley-Ewing, Andrea; Hawes, Starlyn; Moore, Erin; Williams, Eric; Martinez, David; Goggin, Kathy
2014-01-01
Utilizing a community-based participatory research (CBPR) approach is a potentially effective strategy for exploring the development, implementation, and evaluation of HIV interventions in African American churches. This CBPR-guided study describes a church-based HIV awareness and screening intervention (Taking It to the Pews [TIPS]) that fully involved African American church leaders in all phases of the research project. Findings from the implementation and evaluation phases indicated that church leaders delivered TIPS Tool Kit activities on an ongoing basis (about twice a month) over a 9-month period. TIPS church members were highly exposed to TIPS activities (e.g., 91% reported receiving HIV educational brochures, 84% heard a sermon about HIV). Most (87%) believed that the church should talk about HIV, and 77% believed that the church should offer HIV screening. These findings suggest that implementing an HIV intervention in Black church settings is achievable, particularly when a CBPR approach is used. PMID:20528130
Pelizzo, Gloria; Quaretti, Pietro; Moramarco, Lorenzo Paolo; Corti, Riccardo; Maestri, Marcello; Iacob, Giulio; Calcaterra, Valeria
2017-01-01
Transjugular intrahepatic portosystemic shunt (TIPS) placement is a standard procedure for the treatment of portal hypertension complications. When this conventional approach is not feasible, alternative procedures for systemic diversion of portal blood have been proposed. A one-step interventional approach, combining minilaparotomy-assisted transmesenteric (MAT) antegrade portal recanalization and TIPS, is described in an adolescent with recurrent esophageal varice bleeding and portal cavernoma (PC). A 16-year-old girl was admitted to our Unit because of repeated bleeding episodes over a short period of time due to esophageal varices in the context of a PC. A portal vein recanalization through an ileocolic vein isolation with the MAT approach followed by TIPS during the same session was performed. In the case of failed portal recanalization, this approach, would also be useful for varice endovascular embolization. Postoperative recovery was uneventful. Treatment consisting of propanolol, enoxaparin and a proton pump inhibitor was prescribed after the procedure. One month post-op, contrast enhanced computed tomography confirmed the patency of the portal and intrahepatic stent grafts. No residual peritoneal fluid was detected nor opacification of the large varices. Endoscopy showed good improvement of the varices. Doppler ultrasound confirmed the accelerated flow in the portal stent and hepatopetal flow inside the intrahepatic portal branches. Three months post-op, TIPS maintained its hourglass shape despite a slight expansion. Portal hypertension and life threatening conditions related to PC would benefit from one-step portal recanalization. MAT-TIPS is feasible and safe for the treatment of PC even in children. This minimally invasive procedure avoids or delays surgical treatment or re-transplantation when necessary in pediatric patients. PMID:28487619
Jesse, Stephen; Kalinin, Sergei V; Nikiforov, Maxim P
2013-07-09
An approach for the thermomechanical characterization of phase transitions in polymeric materials (polyethyleneterephthalate) by band excitation acoustic force microscopy is developed. This methodology allows the independent measurement of resonance frequency, Q factor, and oscillation amplitude of a tip-surface contact area as a function of tip temperature, from which the thermal evolution of tip-surface spring constant and mechanical dissipation can be extracted. A heating protocol maintained a constant tip-surface contact area and constant contact force, thereby allowing for reproducible measurements and quantitative extraction of material properties including temperature dependence of indentation-based elastic and loss moduli.
CO tip functionalization in subatomic resolution atomic force microscopy
NASA Astrophysics Data System (ADS)
Kim, Minjung; Chelikowsky, James R.
2015-10-01
Noncontact atomic force microscopy (nc-AFM) employing a CO-functionalized tip displays dramatically enhanced resolution wherein covalent bonds of polycyclic aromatic hydrocarbon can be imaged. Employing real-space pseudopotential first-principles calculations, we examine the role of CO in functionalizing the nc-AFM tip. Our calculations allow us to simulate full AFM images and ascertain the enhancement mechanism of the CO molecule. We consider two approaches: one with an explicit inclusion of the CO molecule and one without. By comparing our simulations to existing experimental images, we ascribe the enhanced resolution of the CO functionalized tip to the special orbital characteristics of the CO molecule.
CO tip functionalization in subatomic resolution atomic force microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Minjung; Chelikowsky, James R.
2015-10-19
Noncontact atomic force microscopy (nc-AFM) employing a CO-functionalized tip displays dramatically enhanced resolution wherein covalent bonds of polycyclic aromatic hydrocarbon can be imaged. Employing real-space pseudopotential first-principles calculations, we examine the role of CO in functionalizing the nc-AFM tip. Our calculations allow us to simulate full AFM images and ascertain the enhancement mechanism of the CO molecule. We consider two approaches: one with an explicit inclusion of the CO molecule and one without. By comparing our simulations to existing experimental images, we ascribe the enhanced resolution of the CO functionalized tip to the special orbital characteristics of the CO molecule.
Hoang, Jenny K; Vanka, Jyotsna; Ludwig, Benjamin J; Glastonbury, Christine M
2013-01-01
In this article, we present a 4-step approach to evaluating lymph nodes in the setting of head and neck squamous cell and thyroid carcinoma and highlight important tips and traps. The presence and extent of nodal metastases in head and neck cancer has a great impact on treatment and prognosis. Pretreatment CT and MRI of the neck are commonly performed to evaluate for nodal metastases.
Surgical tool detection and tracking in retinal microsurgery
NASA Astrophysics Data System (ADS)
Alsheakhali, Mohamed; Yigitsoy, Mehmet; Eslami, Abouzar; Navab, Nassir
2015-03-01
Visual tracking of surgical instruments is an essential part of eye surgery, and plays an important role for the surgeons as well as it is a key component of robotics assistance during the operation time. The difficulty of detecting and tracking medical instruments in-vivo images comes from its deformable shape, changes in brightness, and the presence of the instrument shadow. This paper introduces a new approach to detect the tip of surgical tool and its width regardless of its head shape and the presence of the shadows or vessels. The approach relies on integrating structural information about the strong edges from the RGB color model, and the tool location-based information from L*a*b color model. The probabilistic Hough transform was applied to get the strongest straight lines in the RGB-images, and based on information from the L* and a*, one of these candidates lines is selected as the edge of the tool shaft. Based on that line, the tool slope, the tool centerline and the tool tip could be detected. The tracking is performed by keeping track of the last detected tool tip and the tool slope, and filtering the Hough lines within a box around the last detected tool tip based on the slope differences. Experimental results demonstrate the high accuracy achieved in term of detecting the tool tip position, the tool joint point position, and the tool centerline. The approach also meets the real time requirements.
Technical aspects of contrast-enhanced ultrasound (CEUS) examinations: tips and tricks.
Greis, C
2014-01-01
Ultrasound contrast agents have substantially extended the clinical value of ultrasound, allowing the assessment of blood flow and distribution in real-time down to microcapillary level. Selective imaging of contrast agent signals requires a contrast-specific imaging mode on the ultrasound scanner, allowing real-time separation of tissue and contrast agent signals. The creation of a contrast image requires a specific interaction between the insonated ultrasound wave and the contrast agent microbubbles, leading to persistent oscillation of the bubbles. Several technical and procedural parameters have a significant influence on the quality of CEUS images and should be controlled carefully to obtain good image quality and a reliable diagnosis. Achieving the proper balance between the respective parameters is a matter of technical knowledge and experience. Appropriate training and education should be mandatory for every investigator performing CEUS examinations.
Test Rig for Active Turbine Blade Tip Clearance Control Concepts: An Update
NASA Technical Reports Server (NTRS)
Taylor, Shawn; Steinetz, Bruce; Oswald, Jay; DeCastro, Jonathan; Melcher, Kevin
2006-01-01
The objective is to develop and demonstrate a fast-acting active clearance control system to improve turbine engine performance, reduce emissions, and increase service life. System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA's Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.
2006-01-01
Nanosensors and Instrumentation Nanotechnology in Space Exploration 19 simple, rugged design. Multiwalled carbon nanotube ( MWCNT ) cathodes were grown...probe tips. Existing approaches use both SWCNTs and MWCNTs . A unique fabrication process development at NASA Ames (see ref. [4] in Chapter 6...produces very robust MWCNT tips with a high aspect ratio (> 1 µm in length and 10 nm to 20 nm in diameter). In addition, a novel and simple tip sharpening
Preventing Seal Leak During Negative Pressure Wound Therapy Near External Fixators: A Technical Tip.
Mannino, Brian J; Pullen, Michael W; Gaines, Robert
2017-03-01
Negative pressure wound therapy is an effective tool for the treatment of open wounds. Occasionally these wounds are associated with injuries or procedures that require treatment with an external fixator. This article shows how a simple, inexpensive, and commercially available product can be used to prevent loss of suction around external fixator pins within the negative pressure wound treatment area.
Engineering Therapies that Evolve to Autonomously Control Epidemics
2017-06-01
FINAL TECHNICAL REPORT Grant No. D15AP00024 “ Engineering Therapies that Evolve to Autonomously Control Epidemics” PI: Leor Weinberger...viruses could be engineered into therapeutics, known as Therapeutic Interfering Particles (’TIPs’), using the virus HIV as a model system. By engineering ... engineered TIPs could have indefinite, population-scale impact. To achieve this aim, we developed novel multi-scale models that connected the measured
Chautauqua notebook: appropriate technology on radio
DOE Office of Scientific and Technical Information (OSTI.GOV)
Renz, B.
1981-01-01
Experiences in establishing and maintaining a regional call-in information-exchange radio show (Chautauqua) on energy conservation, appropriate technology, renewable energy sources, and self-reliance are discussed. Information is presented on: appropriate technology; the Chautauquaa concept; topics discussed; research performed; guests; interviewing tips; types of listeners; program features; where to find help; promotion and publicity; the technical and engineering aspects; the budget and funding; and station policies. (MCW)
Percutaneous Treatment of Coronary Chronic Total Occlusion Part 2: Technical Approach
Galassi, Alfredo; Grantham, Aaron; Kandzari, David; Lombardi, William; Moussa, Issam; Thompson, Craig; Werner, Gerald; Chambers, Charles
2014-01-01
Dual injection is recommended for nearly all chronic total occlusion (CTO) percutaneous coronary intervention (PCI) to determine the optimal crossing strategy and guide wire advancement into the distal true lumen. Strategies that provide enhanced guide catheter support (such as long sheaths, large-bore guiding catheters, use of guide catheter extensions, and anchor techniques) are important for maximising the success rate and efficiency of CTO PCI. Use of a microcatheter or over-the-wire balloon is strongly recommended in CTO PCI for enhancing the penetrating power of the guidewire, enabling change in tip shape and allowing guidewire change (stiff CTO guidewires are not optimal for crossing non-occluded coronary segments). Adherence to a procedural strategy that standardises CTO technique and facilitates procedural success is recommended. Such a strategy would permit stepwise decision-making for antegrade and retrograde methods; inform guidewire selection; and incorporate alternative approaches for instances of initial failure. Given the paucity of long-term outcomes with use of novel crossing techniques (antegrade dissection/re-entry and retrograde), antegrade wire escalation is the preferred CTO crossing technique, if technically feasible. Using measures to minimise radiation exposure (including but not limited to use of 7.5 frames per second fluoroscopy and use of low magnification) and contrast administration is recommended. CTO PCI is best performed at centres with dedicated CTO PCI experience and expertise. Use of crossing difficulty prediction tools, such as the J-CTO score, can facilitate the selection of cases with a high likelihood of quick crossing that can be attempted at less experienced centres. PMID:29588803
Conrad, Marcelo D; Brasiliense, Leonardo B C; Richie, Alexa N; Hanel, Ricardo A
2014-05-01
Many endovascular techniques have been described in recent years for the management of wide necked aneurysms. The Y stent assisted technique has been generally used for coil embolization of wide necked bifurcation aneurysms. This technique was first described for the treatment of basilar tip aneurysms in combination with several different devices, demonstrating encouraging results. We report the results of the first two cases of wide necked basilar tip aneurysms treated with Y stent assisted coil embolization using a new low profile visible intraluminal stent (LVIS Jr; MicroVention, Tustin, California, USA) delivered through a 0.017 inch microcatheter. We also reviewed the literature comparing other endovascular techniques (coiling alone, stent assisted coiling, and Y stent assisted coiling) for wide necked aneurysms. The LVIS Jr device offers a new option for the treatment of these challenging lesions, with clear advantages over currently available intracranial stents. Larger series and long term results are needed to confirm the applicability and durability of this technique/technology.
Technical tips during implantation of selective upper airway stimulation.
Heiser, Clemens; Thaler, Erica; Soose, Ryan J; Woodson, B Tucker; Boon, Maurits
2018-03-01
Selective upper airway stimulation is now well-established in the United States and in several European countries, with more than 1,000 patients implanted since U.S. Food and Drug Administration approval in April 2014. The authors herein, all head and neck surgeons, account for approximately one of every five implants completed to date. Several of the authors also provide comprehensive longitudinal care of their patients as dual-specialty sleep medicine physicians. Multi-center, retrospective clinical analysis. More than 300 implants have been evaluated and reviewed in five different implant centers (Germany, United States). This analysis shares tips and techniques from the collective experiences with more than 300 implants, which can help newer implanters learn vicariously both for standard practices in executing routine implants through activation and, importantly, for working through more challenging encounters with anatomy, special patient phenotypes, system testing, and troubleshooting. These tips should help new implanters handle most of the situations arising during implantation and avoid common pitfalls. Laryngoscope, 128:756-762, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
The MROI fast tip-tilt correction and target acquisition system
NASA Astrophysics Data System (ADS)
Young, John; Buscher, David; Fisher, Martin; Haniff, Christopher; Rea, Alexander; Seneta, Eugene B.; Sun, Xiaowei; Wilson, Donald; Farris, Allen; Olivares, Andres; Selina, Robert
2012-07-01
The fast tip-tilt correction system for the Magdalena Ridge Observatory Interferometer (MROI) is being designed and fabricated by the University of Cambridge. The design of the system is currently at an advanced stage and the performance of its critical subsystems has been verified in the laboratory. The system has been designed to meet a demanding set of specifications including satisfying all performance requirements in ambient temperatures down to -5 °C, maintaining the stability of the tip-tilt fiducial over a 5 °C temperature change without recourse to an optical reference, and a target acquisition mode with a 60” field-of-view. We describe the important technical features of the system, which uses an Andor electron-multiplying CCD camera protected by a thermal enclosure, a transmissive optical system with mounts incorporating passive thermal compensation, and custom control software running under Xenomai real-time Linux. We also report results from laboratory tests that demonstrate (a) the high stability of the custom optic mounts and (b) the low readout and compute latencies that will allow us to achieve a 40 Hz closed-loop bandwidth on bright targets.
Tips, Tropes, and Trivia: Ideas for Teaching Educational Research.
ERIC Educational Resources Information Center
Stallings, William M.; And Others
The collective experience of more than 50 years has led to the development of approaches that have enhanced student comprehension in the teaching of educational research methods, statistics, and measurement. Tips for teachers include using illustrative problems with one-digit numbers, using common situations and everyday objects to illustrate…
A Novel Approach for Reducing Rotor Tip-Clearance Induced Noise in Turbofan Engines
NASA Technical Reports Server (NTRS)
Khorrami, Mehdi R.; Li, Fei; Choudhari, Meelan
2001-01-01
Rotor tip-clearance induced noise, both in the form of rotor self noise and rotor-stator interaction noise , constitutes a significant component of total fan noise. Innovative yet cost effective techniques to suppress rotor-generated noise are, therefore, of foremost importance for improving the noise signature of turbofan engines. To that end, the feasibility of a passive porous treatment strategy to positively modify the tip-clearance flow field is addressed. The present study is focused on accurate viscous flow calculations of the baseline and the treated rotor flow fields. Detailed comparison between the computed baseline solution and experimental measurements shows excellent agreement. Tip-vortex structure, trajectory, strength, and other relevant aerodynamic quantities are extracted from the computed database. Extensive comparison between the untreated and treated tip-clearance flow fields is performed. The effectiveness of the porous treatment for altering the rotor-tip vortex flow field in general and reducing the intensity of the tip vortex, in particular, is demonstrated. In addition, the simulated flow field for the treated tip clearly shows that substantial reduction in the intensity of both the shear layer roll-up and boundary layer separation on the wall is achieved.
An optical fiber bundle sensor for tip clearance and tip timing measurements in a turbine rig.
García, Iker; Beloki, Josu; Zubia, Joseba; Aldabaldetreku, Gotzon; Illarramendi, María Asunción; Jiménez, Felipe
2013-06-05
When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions.
An Optical Fiber Bundle Sensor for Tip Clearance and Tip Timing Measurements in a Turbine Rig
García, Iker; Beloki, Josu; Zubia, Joseba; Aldabaldetreku, Gotzon; Illarramendi, María Asunción; Jiménez, Felipe
2013-01-01
When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions. PMID:23739163
Identifying tips for intramolecular NC-AFM imaging via in situ fingerprinting
NASA Astrophysics Data System (ADS)
Sang, Hongqian; Jarvis, Samuel P.; Zhou, Zhichao; Sharp, Peter; Moriarty, Philip; Wang, Jianbo; Wang, Yu; Kantorovich, Lev
2014-10-01
A practical experimental strategy is proposed that could potentially enable greater control of the tip apex in non-contact atomic force microscopy experiments. It is based on a preparation of a structure of interest alongside a reference surface reconstruction on the same sample. Our proposed strategy is as follows. Spectroscopy measurements are first performed on the reference surface to identify the tip apex structure using a previously collected database of responses of different tips to this surface. Next, immediately following the tip identification protocol, the surface of interest is studied (imaging, manipulation and/or spectroscopy). The prototype system we choose is the mixed Si(111)-7×7 and surface which can be prepared on the same sample with a controlled ratio of reactive and passivated regions. Using an ``in silico'' approach based on ab initio density functional calculations and a set of tips with varying chemical reactivities, we show how one can perform tip fingerprinting using the Si(111)-7×7 reference surface. Then it is found by examining the imaging of a naphthalene tetracarboxylic diimide (NTCDI) molecule adsorbed on surface that negatively charged tips produce the best intramolecular contrast attributed to the enhancement of repulsive interactions.
Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Caudrelier, Jean; Bauones, Salem; Tsoumakidou, Georgia; Koch, Guillaume; Gangi, Afshin
2017-09-01
To present a new blunt-tip coaxial needle (SoftGuard) applied to access "hard-to-reach" targets undergoing percutaneous image-guided biopsy or drainage. All consecutive patients presenting between August and December 2016 with "hard-to-reach" (<10 mm from a critical nearby structure such as vessels, nerves, bowel or adjacent parenchymal organs) solid lesions requiring biopsy (group A) or abscesses requiring drainage for sepsis (group B) were prospectively included. The individual features of each patient and lesion as well as technical and clinical data were collected and analysed. Twenty-six patients (18 males, 8 females, mean age 59.81 ± 17.53 years) were enrolled in group A and nine (6 males, 3 females, mean age 58.33 ± 13.8 years) in group B. Technical success was achieved in 92.3% of cases from group A and 100% of cases from group B. Five (19.2%) minor complications were noted in group A (four small self-limiting pneumothoraces and one small self-limiting peri-pancreatic haematoma). There were no complications in group B. Histological results in group A accounted for 95% sensitivity, 100% specificity and 95.2% diagnostic accuracy. In group B, mean post-operative C-reactive protein was 41 ± 48.3 mg/L in comparison with 155 ± 117.5 mg/L at baseline (P = 0.004). The SoftGuard blunt-tip needle is a safe and effective tool when applied as a coaxial working cannula for percutaneous biopsy or drainage of "hard-to-reach" targets.
Aerodynamic Characteristics of Low-Aspect-Ratio Wings in Close Proximity to the Ground
NASA Technical Reports Server (NTRS)
Fink, Marvin P.; Lastinger, James L.
1961-01-01
A wind-tunnel investigation has been conducted to determine the effect of ground proximity on the aerodynamic characteristics of thick highly cambered rectangular wings with aspect ratios of 1. 2, 4, and 6. The results showed that, for these aspect ratios, as the ground war, approached all wings experienced increases in lift-curve slope and reductions in induced drag which resulted in increases in lift-drag ratio. Although an increase in lift-curve slope was obtained for all aspect ratios as the ground was approached, the lift coefficient at an angle of attack of 0 deg for any given aspect ratio remained nearly constant. The experimental results were in general agreement with Wieselsberger's ground-effect theory (NACA Technical Memorandum 77). As the wings approached the ground, there was an increase in static longitudinal stability at positive angles of attack. When operating in ground effect, all the wings had stability of height at positive angles of attack and instability of height at negative angles of attack. Wing-tip fairings on the wings with aspect ratios of 1 and 2 produced small increases in lift-drag ratio in ground effect. End plates extending only below the chord plane on the wing with an aspect ratio of 1 provided increases in lift coefficient and in lift-drag ratio in ground effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Rodt, Thomas, E-mail: rodt.thomas@mh-hannover.de; Rosenthal, Herbert, E-mail: rosenthal.herbert@mh-hannover.de
PurposeTo assess the impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portoystemic shunt following standard operating procedure (SOP).Material and MethodsDuring a 32-month period, 102 patients underwent transjugular intrahepatic portosystemic shunt creation (TIPS) by two interventional radiologists (IR) following our institutional SOP based on fluoroscopy guidance. Both demographic and procedural data were assessed. The duration of the intervention (D{sub Int}) and of the portal vein puncture (D{sub Punct}) was analyzed depending on the skill level of the IR as well as the anatomic or procedural factors.ResultsIn 99 of the 102 patients, successfulmore » TIPS without peri-procedural complications was performed. The mean D{sub Int} (IR1: 77 min; IR2: 51 min, P < 0.005) and the mean D{sub Punct} (IR1: 19 min; IR2: 13 min, P < 0.005) were significantly higher in TIPS performed by IR1 (with 2 years of clinical experience performing TIPS, n = 38) than by IR2 (>10 years of clinical experience performing TIPS, n = 61), (P < 0.005 both, Mann–Whitney U test). D{sub Int} showed a higher correlation with D{sub Punct} for IR2 (R{sup 2} = 0.63) than for IR1 (R{sup 2} = 0.13). There was no significant difference in the D{sub Punct} for both IRs with regard to the success of the wedged portography (P = 0.90), diameter of the portal vein (P = 0.60), central right portal vein length (P = 0.49), or liver function (MELD-Score before the TIPS procedure; P = 0.14).ConclusionTIPS following SOP is safe, fast, and reliable. The only significant factor for shorter D{sub Punct} and D{sub Int} was the clinical experience of the IR. Anatomic variability, successful portography, or liver function did not alter the duration or technical success of TIPS.« less
NASA Technical Reports Server (NTRS)
Whitcomb, R. T.
1976-01-01
Winglets, which are small, nearly vertical, winglike surfaces, substantially reduce drag coefficients at lifting conditions. The primary winglet surfaces are rearward above the wing tips; secondary surfaces are forward below the wing tips. This report presents a discussion of the considerations involved in the design of the winglets; measured effects of these surfaces on the aerodynamic forces, moments, and loads for a representative first generation, narrow body jet transport wing; and a comparison of these effects with those for a wing tip extension which results in approximately the same increase in bending moment at the wing-fuselage juncture as did the addition of the winglets.
van Vörden, Dennis; Möller, Rolf
2012-01-01
Summary Measurements of the frequency shift versus distance in noncontact atomic force microscopy (NC-AFM) allow measurements of the force gradient between the oscillating tip and a surface (force-spectroscopy measurements). When nonconservative forces act between the tip apex and the surface the oscillation amplitude is damped. The dissipation is caused by bistabilities in the potential energy surface of the tip–sample system, and the process can be understood as a hysteresis of forces between approach and retraction of the tip. In this paper, we present the direct measurement of the whole hysteresis loop in force-spectroscopy curves at 77 K on the PTCDA/Ag/Si(111) √3 × √3 surface by means of a tuning-fork-based NC-AFM with an oscillation amplitude smaller than the distance range of the hysteresis loop. The hysteresis effect is caused by the making and breaking of a bond between PTCDA molecules on the surface and a PTCDA molecule at the tip. The corresponding energy loss was determined to be 0.57 eV by evaluation of the force–distance curves upon approach and retraction. Furthermore, a second dissipation process was identified through the damping of the oscillation while the molecule on the tip is in contact with the surface. This dissipation process occurs mainly during the retraction of the tip. It reaches a maximum value of about 0.22 eV/cycle. PMID:22496993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mishchenko, L; Khan, M; Aizenberg, J
Certain natural organisms use micro-patterned surface chemistry, or ice-nucleating species, to control water condensation and ice nucleation for survival under extreme conditions. As an analogy to these biological approaches, it is shown that functionalized, hydrophilic polymers and particles deposited on the tips of superhydrophobic posts induce precise topographical control over water condensation and freezing at the micrometer scale. A bottom-up deposition process is used to take advantage of the limited contact area of a non-wetting aqueous solution on a superhydrophobic surface. Hydrophilic polymer deposition on the tips of these geometrical structures allows spatial control over the nucleation, growth, and coalescencemore » of micrometer-scale water droplets. The hydrophilic tips nucleate water droplets with extremely uniform nucleation and growth rates, uniform sizes, an increased stability against coalescence, and asymmetric droplet morphologies. Control of freezing behavior is also demonstrated via deposition of ice-nucleating AgI nanoparticles on the tips of these structures. This combination of the hydrophilic polymer and AgI particles on the tips was used to achieve templating of ice nucleation at the micrometer scale. Preliminary results indicate that control over ice crystal size, spatial symmetry, and position might be possible with this method. This type of approach can serve as a platform for systematically analyzing micrometer-scale condensation and freezing phenomena, and as a model for natural systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mishchenko, Lidiya; Khan, M.; Aizenberg, Joanna
Certain natural organisms use micro-patterned surface chemistry, or ice-nucleating species, to control water condensation and ice nucleation for survival under extreme conditions. As an analogy to these biological approaches, it is shown that functionalized, hydrophilic polymers and particles deposited on the tips of superhydrophobic posts induce precise topographical control over water condensation and freezing at the micrometer scale. A bottom-up deposition process is used to take advantage of the limited contact area of a non-wetting aqueous solution on a superhydrophobic surface. Hydrophilic polymer deposition on the tips of these geometrical structures allows spatial control over the nucleation, growth, and coalescencemore » of micrometer-scale water droplets. The hydrophilic tips nucleate water droplets with extremely uniform nucleation and growth rates, uniform sizes, an increased stability against coalescence, and asymmetric droplet morphologies. Furthermore, control of freezing behavior is also demonstrated via deposition of ice-nucleating AgI nanoparticles on the tips of these structures. The combination of the hydrophilic polymer and AgI particles on the tips was used to achieve templating of ice nucleation at the micrometer scale. Preliminary results indicate that control over ice crystal size, spatial symmetry, and position might be possible with this method. This type of approach can serve as a platform for systematically analyzing micrometer-scale condensation and freezing phenomena, and as a model for natural systems.« less
NASA Astrophysics Data System (ADS)
Fujimoto, Takahiro; Imai, Yusuke; Tei, Kazuyoku; Fujioka, Tomoo; Yamaguchi, Shigeru
2013-03-01
In most of medical and dental laser treatments, high power pulsed laser have been used as desirable light sources employing with an optical fiber delivery system. The treatment process involves high temperature thermal effect associated with direct laser absorption of the materials such as hard and soft tissues, tooth, bones and so on. Such treatments sometimes face technical difficulties suffering from their optical absorption properties. We investigate a new technology to create high temperature heat source on the tip surface of the glass fiber proposed for the medical surgery applications. Using a low power level (4 6W) semiconductor laser at a wavelength of 980nm, a laser coupled fiber tip was pre-processed to contain certain amount of TiO2 powder with a depth of 400μm from the tip surface so that the irradiated low laser energy could be perfectly absorbed to be transferred to thermal energy. Thus the laser treatment can be performed without suffering from any optical characteristic of the material. Semiconductor laser was operated quasi-CW mode pulse time duration of 180ms and more than 95% of the laser energy was converted to thermal energy in the fiber tip. by Based on twocolor thermometry by using a gated optical multichannel analyzer with 0.25m spectrometer in visible wavelength region, the temperature of the fiber tip was analyzed. The temperature of the heat source was measured to be approximately 3000K. Demonstration of laser processing employing this system was successfully carried out drilling through holes in ceramic materials simulating bone surgery.
A Dynamic Mesh-Based Approach to Model Melting and Shape of an ESR Electrode
NASA Astrophysics Data System (ADS)
Karimi-Sibaki, E.; Kharicha, A.; Bohacek, J.; Wu, M.; Ludwig, A.
2015-10-01
This paper presents a numerical method to investigate the shape of tip and melt rate of an electrode during electroslag remelting process. The interactions between flow, temperature, and electromagnetic fields are taken into account. A dynamic mesh-based approach is employed to model the dynamic formation of the shape of electrode tip. The effect of slag properties such as thermal and electrical conductivities on the melt rate and electrode immersion depth is discussed. The thermal conductivity of slag has a dominant influence on the heat transfer in the system, hence on melt rate of electrode. The melt rate decreases with increasing thermal conductivity of slag. The electrical conductivity of slag governs the electric current path that in turn influences flow and temperature fields. The melting of electrode is a quite unstable process due to the complex interaction between the melt rate, immersion depth, and shape of electrode tip. Therefore, a numerical adaptation of electrode position in the slag has been implemented in order to achieve steady state melting. In fact, the melt rate, immersion depth, and shape of electrode tip are interdependent parameters of process. The generated power in the system is found to be dependent on both immersion depth and shape of electrode tip. In other words, the same amount of power was generated for the systems where the shapes of tip and immersion depth were different. Furthermore, it was observed that the shape of electrode tip is very similar for the systems running with the same ratio of power generation to melt rate. Comparison between simulations and experimental results was made to verify the numerical model.
Unconventional Behavior of Friction at the Nanoscale beyond Amontons' Law.
Chen, Jingrun; Gao, Wang
2017-08-05
By means of a many-body van der Waals (vdW)-corrected density functional theory approach, the atomic-scale friction of a prototypical tip-substrate system consisting of an Si tip and a graphene substrate is studied. In a loading-sliding process, the tip-substrate distance is found to be essential for nanofrictional behavior, through determining the competition between vdW contributions and electronic contributions. As the tip approaches the substrate, this competition results in a smooth transition of normal forces from attraction to repulsion, and the friction coefficient in turn undergoes a sign change from negative to positive with possible giant magnitude and strong anisotropy. The loading-sliding process does not introduce any chemical modification of the underlying system. These findings reveal the boundary of validity of Amontons' law, unify negative and giant friction coefficients, rationalize the experimentally observed anisotropy of nanofriction, and are universal when vdW interactions are crucial, all of which are helpful to establish a comprehensive picture of nanofriction. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Radiative control of dark excitons at room temperature by nano-optical antenna-tip Purcell effect
NASA Astrophysics Data System (ADS)
Park, Kyoung-Duck; Jiang, Tao; Clark, Genevieve; Xu, Xiaodong; Raschke, Markus B.
2018-01-01
Excitons, Coulomb-bound electron-hole pairs, are elementary photo-excitations in semiconductors that can couple to light through radiative relaxation. In contrast, dark excitons (XD) show anti-parallel spin configuration with generally forbidden radiative emission. Because of their long lifetimes, these dark excitons are appealing candidates for quantum computing and optoelectronics. However, optical read-out and control of XD states has remained challenging due to their decoupling from light. Here, we present a tip-enhanced nano-optical approach to induce, switch and programmably modulate the XD emission at room temperature. Using a monolayer transition metal dichalcogenide (TMD) WSe2 on a gold substrate, we demonstrate 6 × 105-fold enhancement in dark exciton photoluminescence quantum yield achieved through coupling of the antenna-tip to the dark exciton out-of-plane optical dipole moment, with a large Purcell factor of ≥2 × 103 of the tip-sample nano-cavity. Our approach provides a facile way to harness excitonic properties in low-dimensional semiconductors offering new strategies for quantum optoelectronics.
Radiative control of dark excitons at room temperature by nano-optical antenna-tip Purcell effect.
Park, Kyoung-Duck; Jiang, Tao; Clark, Genevieve; Xu, Xiaodong; Raschke, Markus B
2018-01-01
Excitons, Coulomb-bound electron-hole pairs, are elementary photo-excitations in semiconductors that can couple to light through radiative relaxation. In contrast, dark excitons (X D ) show anti-parallel spin configuration with generally forbidden radiative emission. Because of their long lifetimes, these dark excitons are appealing candidates for quantum computing and optoelectronics. However, optical read-out and control of X D states has remained challenging due to their decoupling from light. Here, we present a tip-enhanced nano-optical approach to induce, switch and programmably modulate the X D emission at room temperature. Using a monolayer transition metal dichalcogenide (TMD) WSe 2 on a gold substrate, we demonstrate ~6 × 10 5 -fold enhancement in dark exciton photoluminescence quantum yield achieved through coupling of the antenna-tip to the dark exciton out-of-plane optical dipole moment, with a large Purcell factor of ≥2 × 10 3 of the tip-sample nano-cavity. Our approach provides a facile way to harness excitonic properties in low-dimensional semiconductors offering new strategies for quantum optoelectronics.
NASA Technical Reports Server (NTRS)
Kazin, S. B.; Minzner, W. R.; Paas, J. E.
1971-01-01
A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a rotor tip casing bleed slot to determine its effects on noise generation. The bleed slot was located 1/2 inch (1.3 cm) upstream of the rotor leading edge and was configured to be a continuous opening around the circumference. The bleed manifold system was operated over a range of bleed rates corresponding to as much as 6% of the fan flow at approach thrust and 4.25% of the fan flow at takeoff thrust. Acoustic results indicate that a bleed rate of 4% of the fan flow reduces the fan maximum approach 200 foot (61.0 m) sideline PNL 0.5 PNdB and the corresponding takeoff thrust noise 1.1 PNdB below the level with zero bleed. However, comparison of the standard casing (no bleed slot) and the slotted bleed casing with zero bleed shows that the bleed slot itself caused a noise increase.
Bibliography of ceramic extrusion and plasticity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janney, M.A.; Vance, M.C.; Jordan, A.C.
A comprehensive bibliography of ceramic extrusion and plasticity has been compiled. Over 670 abstracts are included covering the period 1932 to 1984. Citations cover a wide range of interests from basic science investigations to engineering ''tips'' and include references to brick and tile, whitewares, technical ceramics, theoretical models, engineering analyses, forming, drying, and raw materials. In addition to the citations, there are numerous indices to make the bibliography easy to use.
Tips and traps for reapplying used process plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conder, M.W.
1999-07-01
Many gas processing projects are based on reapplying used gas processing plants and equipment. There has been little information or advice in the literature which provides practical advice for this type of project. GPA's Technical Section A Committee has been developing a monograph on experiences in reapplying used plants and equipment. This paper includes excerpts from that monograph and presents advice illustrated by recent experiences with used plants.
Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips.
Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas
2016-09-01
Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.
Palmucci, Stefano; Roccasalva, Federica; Piccoli, Marina; Fuccio Sanzà, Giovanni; Foti, Pietro Valerio; Ragozzino, Alfonso; Milone, Pietro; Ettorre, Giovanni Carlo
2017-01-01
Since its introduction, MRCP has been improved over the years due to the introduction of several technical advances and innovations. It consists of a noninvasive method for biliary tree representation, based on heavily T2-weighted images. Conventionally, its protocol includes two-dimensional single-shot fast spin-echo images, acquired with thin sections or with multiple thick slabs. In recent years, three-dimensional T2-weighted fast-recovery fast spin-echo images have been added to the conventional protocol, increasing the possibility of biliary anatomy demonstration and leading to a significant benefit over conventional 2D imaging. A significant innovation has been reached with the introduction of hepatobiliary contrasts, represented by gadoxetic acid and gadobenate dimeglumine: they are excreted into the bile canaliculi, allowing the opacification of the biliary tree. Recently, 3D interpolated T1-weighted spoiled gradient echo images have been proposed for the evaluation of the biliary tree, obtaining images after hepatobiliary contrast agent administration. Thus, the acquisition of these excretory phases improves the diagnostic capability of conventional MRCP-based on T2 acquisitions. In this paper, technical features of contrast-enhanced magnetic resonance cholangiography are briefly discussed; main diagnostic tips of hepatobiliary phase are showed, emphasizing the benefit of enhanced cholangiography in comparison with conventional MRCP.
Centering Pregnancy: practical tips for your practice.
DeCesare, Julie Z; Jackson, Jessica R
2015-03-01
With increased access to care, current health delivery systems will need expansion to meet higher demands and needs. To define Centering Pregnancy and practical tips for implementation into both private and academic practices. Evidence was gathered through literature reviews. It was found that Centering Pregnancy offers a patient-centered, evidence-based approach to helping with access issues, as well as improving outcomes. This article describes the benefits of Centering Pregnancy to the practice, the provider, and the patient. Practical implementation tips will be offered, with suggestions for negating common implementation barriers.
Studies in a transonic rotor aerodynamics and noise facility
NASA Technical Reports Server (NTRS)
Wright, S. E.; Lee, D. J.; Crosby, W.
1984-01-01
The design, construction and testing of a transonic rotor aerodynamics and noise facility was undertaken, using a rotating arm blade element support technique. This approach provides a research capability intermediate between that of a stationary element in a moving flow and that of a complete rotating blade system, and permits the acoustic properties of blade tip elements to be studied in isolation. This approach is an inexpensive means of obtaining data at high subsonic and transonic tip speeds on the effect of variations in tip geometry. The facility may be suitable for research on broad band noise and discrete noise in addition to high-speed noise. Initial tests were conducted over the Mach number range 0.3 to 0.93 and confirmed the adequacy of the acoustic treatment used in the facility to avoid reflection from the enclosure.
Kuran, Ismail; Öreroğlu, Ali Rıza; Efendioğlu, Kamran
2014-09-01
An important consideration in rhinoplasty is maintenance of the applied tip rotation. Different techniques have been proposed to accomplish this. Loss of rotation after surgery not only results in a derotated tip but also can create a supratip deformity. As a supplement to dorsal reconstruction, the authors introduced and applied the lateral crural rein flap technique, whereby cartilage flaps are created from the cephalic portion of the lateral crura to control and stabilize tip rotation. Eleven patients underwent primary open-approach rhinoplasty that included the lateral crural rein technique; the mean follow-up time was 18 months. Excess cephalic portions of the lateral crura were prepared as medial crura-based cartilaginous flaps and were incorporated into the nasal dorsum (similar to spreader grafts) and stabilized to achieve the desired tip rotation. The lateral crural rein flap technique provided stability to the nasal tip while minimizing derotation in the postoperative period. Long-term follow-up revealed maintenance of the nasal tip rotation and symmetric dorsal aesthetic lines. The lateral crural rein flap technique is effective for controlling nasal tip rotation while reducing lateral crural cephalic excess. Longevity of the applied tip rotation is reinforced by secure attachment of the lower nasal cartilage complex to the midvault structures. 4. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.
Kumar, Sunil; Rai, Manoj K; Singh, Narender; Mangal, Manisha
2010-12-01
Shoot tips excised from in vitro proliferated shoots derived from nodal explants of jojoba [Simmondsia chinensis (Link) Schneider] were encapsulated in calcium alginate beads for germplasm exchange and distribution. A gelling matrix of 3 % sodium alginate and 100 mM calcium chloride was found most suitable for formation of ideal calcium alginate beads. Best response for shoot sprouting from encapsulated shoot tips was recorded on 0.8 % agar-solidified full-strength MS medium. Rooting was induced upon transfer of sprouted shoots to 0.8 % agar-solidified MS medium containing 1 mg l(-1) IBA. About 70 % of encapsulated shoot tips were rooted and converted into plantlets. Plants regenerated from encapsulated shoot tips were acclimatized successfully. The present encapsulation approach could also be applied as an alternative method of propagation of desirable elite genotype of jojoba.
Probabilistic Analysis and Design of a Raked Wing Tip for a Commercial Transport
NASA Technical Reports Server (NTRS)
Mason Brian H.; Chen, Tzi-Kang; Padula, Sharon L.; Ransom, Jonathan B.; Stroud, W. Jefferson
2008-01-01
An approach for conducting reliability-based design and optimization (RBDO) of a Boeing 767 raked wing tip (RWT) is presented. The goal is to evaluate the benefits of RBDO for design of an aircraft substructure. A finite-element (FE) model that includes eight critical static load cases is used to evaluate the response of the wing tip. Thirteen design variables that describe the thickness of the composite skins and stiffeners are selected to minimize the weight of the wing tip. A strain-based margin of safety is used to evaluate the performance of the structure. The randomness in the load scale factor and in the strain limits is considered. Of the 13 variables, the wing-tip design was controlled primarily by the thickness of the thickest plies in the upper skins. The report includes an analysis of the optimization results and recommendations for future reliability-based studies.
Radially leaned outlet guide vanes for fan source noise reduction
NASA Technical Reports Server (NTRS)
Kazin, S. B.
1973-01-01
Two quiet engine program half scale fans one with a subsonic and the other with a supersonic fan tip speed at takeoff were run with 30 degree leaned and radial outlet guide vanes. Acoustic data at takeoff fan speed on the subsonic tip speed fan showed decreases in 200-foot sideline noise of from 1 to 2 PNdb. The supersonic tip speed fan a takeoff fan speed, however, showed noise increases of up 3 PNdb and a decrease in fan efficiency. At approach fan speed, the subsonic tip speed fan showed a noise decrease of 2.3 PNdb at the 200-foot sideline maximum angle and an increase in efficiency. The supersonic tip speed fan showed noise increase of 3.5 PNdb and no change in efficiency. The decrease in fan efficiency and the nature of the noise increase largely high frequency broadband noise lead to the speculation that an aerodynamic problem occurred.
Measurements of lightning rod responses to nearby strikes
NASA Astrophysics Data System (ADS)
Moore, C. B.; Aulich, G. D.; Rison, W.
2000-05-01
Following Benjamin Franklin's invention of the lightning rod, based on his discovery that electrified objects could be discharged by approaching them with a metal needle in hand, conventional lightning rods in the U.S. have had sharp tips. In recent years, the role of the sharp tip in causing a lightning rod to act as a strike receptor has been questioned leading to experiments in which pairs of various sharp-tipped and blunt rods have been exposed beneath thunderclouds to determine the better strike receptor. After seven years of tests, none of the sharp Franklin rods or of the so-called “early streamer emitters” has been struck, but 12 blunt rods with tip diameters ranging from 12.7 mm to 25.4 mm have taken strikes. Our field experiments and our analyses indicate that the strike-reception probabilities of Franklin's rods are greatly increased when their tips are made moderately blunt.
Experimental determination of J-Q in the two-parameter characterization of fracture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, S.; Chiang, F.P.
1995-11-01
It is well recognized that using a single parameter to characterize crack tip deformation is no long adequate if constraint is present. Several approaches of two-parameter characterization scheme have been proposed. There are the J-T approach, the J-Q approach of Shih et al and the J-Q approach of Sharma and Aravas. The authors propose a scheme to measure the J and Q of the J-Q theory of Sharma and Aravas. They find that with the addition of Q term the experimentally measured U-field displacement component agrees well with the theoretical prediction. The agreement increases as the crack tip constraint increases.more » The results of a SEN and a CN specimen are presented.« less
Noise from propellers with symmetrical sections at zero blade angle, II
NASA Technical Reports Server (NTRS)
Deming, A F
1938-01-01
In a previous paper (Technical Note No. 605), a theory was developed that required an empirical relation to calculate sound pressures for the higher harmonics. Further investigation indicated that the modified theory agrees with experiment and that the empirical relation was due to an interference phenomenon peculiar to the test arrangement used. Comparison is made between the test results for a two-blade arrangement and the theory. The comparison is made for sound pressures in the plane of the revolving blades for varying values of tip velocity. Comparison is also made at constant tip velocity for all values of azimuth angle B. A further check is made between the theory and the experimental results for the fundamental of a four-blade arrangement with blades of the same dimensions as those used in the two-blade arrangement.
Study of mechanical behavior of AFM silicon tips under mechanical load
NASA Astrophysics Data System (ADS)
Kopycinska-Mueller, M.; Gluch, J.; Köhler, B.
2016-11-01
In this paper we address critical issues concerning calibration of AFM based methods used for nanoscale mechanical characterization of materials. It has been shown that calibration approaches based on macroscopic models for contact mechanics may yield excellent results in terms of the indentation modulus of the sample, but fail to provide a comprehensive and actual information concerning the tip-sample contact radius or the mechanical properties of the tip. Explanations for the severely reduced indentation modulus of the tip included the inadequacies of the models used for calculations of the tip-sample contact stiffness, discrepancies in the actual and ideal shape of the tip, presence of the amorphous silicon phase within the silicon tip, as well as negligence of the actual size of the stress field created in the tip during elastic interactions. To clarify these issues, we investigated the influence of the mechanical load applied to four AFM silicon tips on their crystalline state by exposing them to systematically increasing loads, evaluating the character of the tip-sample interactions via the load-unload stiffness curves, and assessing the state of the tips from HR-TEM images. The results presented in this paper were obtained in a series of relatively simple and basic atomic force acoustic microscopy (AFAM) experiments. The novel combination of TEM imaging of the AFM tips with the analysis of the load-unload stiffness curves gave us a detailed insight into their mechanical behavior under load conditions. We were able to identify the limits for the elastic interactions, as well as the hallmarks for phase transformation and dislocation formation and movement. The comparison of the physical dimensions of the AFM tips, geometry parameters determined from the values of the contact stiffness, and the information on the crystalline state of the tips allowed us a better understanding of the nanoscale contact.
Effect of Tip-Speed Constraints on the Optimized Design of a Wind Turbine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dykes, K.; Resor, B.; Platt, A.
This study investigates the effect of tip-velocity constraints on system levelized cost of energy (LCOE). The results indicate that a change in maximum tip speed from 80 to 100~m/s could produce a 32% decrease in gearbox weight (a 33% reduction in cost) which would result in an overall reduction of 1%-9% in system LCOE depending on the design approach. Three 100~m/s design cases were considered including a low tip-speed ratio/high-solidity rotor design, a high tip-speed ratio/ low-solidity rotor design, and finally a flexible blade design in which a high tip-speed ratio was used along with removing the tip deflection constraintmore » on the rotor design. In all three cases, the significant reduction in gearbox weight caused by the higher tip-speed and lower overall gear ratio was counterbalanced by increased weights for the rotor and/or other drivetrain components and the tower. As a result, the increased costs of either the rotor or drivetrain components offset the overall reduction in turbine costs from down-sizing the gearbox. Other system costs were not significantly affected, whereas energy production was slightly reduced in the 100~m/s case low tip-speed ratio case and increased in the high tip-speed ratio case. This resulted in system cost of energy reductions moving from the 80~m/s design to the 100~m/s designs of 1.2% for the low tip-speed ratio, 4.6% for the high tip-speed ratio, and 9.5% for the final flexible case (the latter result is optimistic because the impact of deflection of the flexible blade on power production was not modeled). Overall, the results demonstrate that there is a trade-off in system design between the maximum tip velocity and the overall wind plant cost of energy, and there are many trade-offs within the overall system in designing a turbine for a high maximum tip velocity.« less
NASA Astrophysics Data System (ADS)
Favors, J.; Ruiz, M. L.; Rogers, L.; Ross, K. W.; Childs-Gleason, L. M.; Allsbrook, K. N.
2017-12-01
Over a five-year period that spanned two administrations, NASA's DEVELOP National Program engaged in a partnership with the Government of the Commonwealth of Virginia to explore the use of Earth observations in state-level decision making. The partnership conducted multiple applied remote sensing projects with DEVELOP and utilized a shared-space approach, where the Virginia Governor's Office hosted NASA DEVELOP participants to mature the partnership and explore additional science opportunities in the Commonwealth. This presentation will provide an overview of various lessons learned from working in an administrative and policy environment, fostering the use of science in such an environment, and building substantive relationships with non-technical partners. An overview of the projects conducted in this partnership will provide an opportunity to explore specific best practices that enhanced the work and provide tips to enhance the potential for success for other science and technology organizations considering similar partnerships.
Reconstruction of Long Bone Infections Using the Induced Membrane Technique: Tips and Tricks.
Mauffrey, Cyril; Hake, Mark E; Chadayammuri, Vivek; Masquelet, Alain-Charles
2016-06-01
The management of posttraumatic long bone osteomyelitis remains a challenging clinical problem. A systematic approach is necessary, beginning with eradication of the infected bone and soft tissue. There are a number of options for reconstruction of the remaining bone defect, including the induced membrane technique developed by Masquelet. We describe our technique for the 2-stage treatment of long bone osteomyelitis. The first stage involves a radical debridement, stabilization of the bone with either external fixation or an antibiotic-coated intramedullary nail, and placement of a polymethylmethacrylate spacer. The second stage includes excision of the spacer and placement of autologous bone graft. Various resection methods, fixation strategies, antibiotic additives, and types of bone grafts or substitutes can be used. The purpose of our technical article is to share our personal experience and describe several nuances that are critical for the success of this treatment strategy. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Enhanced Performance Consistency in Nanoparticle/TIPS Pentacene-Based Organic Thin Film Transistors
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Zhengran; Xiao, Kai; Durant, William Mark
2011-01-01
In this study, inorganic silica nanoparticles are used to manipulate the morphology of 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS pentacene) thin films and the performance of solution-processed organic thin-film transistors (OTFTs). This approach is taken to control crystal anisotropy, which is the origin of poor consistency in TIPS pentacene based OTFT devices. Thin film active layers are produced by drop-casting mixtures of SiO{sub 2} nanoparticles and TIPS pentacene. The resultant drop-cast films yield improved morphological uniformity at {approx}10% SiO{sub 2} loading, which also leads to a 3-fold increase in average mobility and nearly 4 times reduction in the ratio of measured mobility standard deviationmore » ({mu}{sub Stdev}) to average mobility ({mu}{sub Avg}). Grazing-incidence X-ray diffraction, scanning and transmission electron microscopy as well as polarized optical microscopy are used to investigate the nanoparticle-mediated TIPS pentacene crystallization. The experimental results suggest that the SiO{sub 2} nanoparticles mostly aggregate at TIPS pentacene grain boundaries, and 10% nanoparticle concentration effectively reduces the undesirable crystal misorientation without considerably compromising TIPS pentacene crystallinity.« less
Geng, Chao; Luo, Wen; Tan, Yi; Liu, Hongmei; Mu, Jinbo; Li, Xinyang
2013-10-21
A novel approach of tip/tilt control by using divergence cost function in stochastic parallel gradient descent (SPGD) algorithm for coherent beam combining (CBC) is proposed and demonstrated experimentally in a seven-channel 2-W fiber amplifier array with both phase-locking and tip/tilt control, for the first time to our best knowledge. Compared with the conventional power-in-the-bucket (PIB) cost function for SPGD optimization, the tip/tilt control using divergence cost function ensures wider correction range, automatic switching control of program, and freedom of camera's intensity-saturation. Homemade piezoelectric-ring phase-modulator (PZT PM) and adaptive fiber-optics collimator (AFOC) are developed to correct piston- and tip/tilt-type aberrations, respectively. The PIB cost function is employed for phase-locking via maximization of SPGD optimization, while the divergence cost function is used for tip/tilt control via minimization. An average of 432-μrad of divergence metrics in open loop has decreased to 89-μrad when tip/tilt control implemented. In CBC, the power in the full width at half maximum (FWHM) of the main lobe increases by 32 times, and the phase residual error is less than λ/15.
Teaching American History: Structured Inquiry Approaches. SSEC Publication No. 185.
ERIC Educational Resources Information Center
Linden, Glenn M., Ed.; Downey, Matthew T., Ed.
This paper is one of a series of ERIC/ChESS publications intended to give practical tips on teaching various topics and disciplines in the precollege social studies curriculum. The tips offered in this publication, written by seven authors, are intended to help teacheres deal with both content and teaching strategies in American history. Each of…
A Case Study of Team-Initiated Problem Solving Addressing Student Behavior in One Elementary School
ERIC Educational Resources Information Center
Todd, Anne W.; Horner, Robert H.; Berry, Dorothy; Sanders, Carol; Bugni, Michelle; Currier, Allison; Potts, Nicky; Newton, J. Stephen; Algozzine, Bob; Algozzine, Kate
2012-01-01
Team-Initiated Problem Solving (TIPS) is an approach for organizing school team meetings to improve identification of targeted problems, use of data in the development of solutions, and development of implemented action plans. TIPS has been demonstrated in single-case and randomized controlled trial studies to improve the effectiveness of teams to…
ERIC Educational Resources Information Center
Swan, Malcolm D., Ed.
A revision of the Lorado Taft Field Campus' 1968 "Instructional Materials Packet" on providing children with educational experiences outside the classroom, this book contains materials, tips, worksheets, and plans for offering students an opportunity for supplementary outdoor experiences in a variety of subject-matter areas: animal studies,…
Intranasal approach for manipulating the depressor septi nasi.
Oh, Sang-Ha; Choi, Sangmun; Kim, Dong Woon; Jeong, Jae Yong
2012-03-01
A hyperactivated depressor septi nasi is an important factor contributing to nasal tip drooping. Although many studies have examined this, its treatment remains controversial. This study presents a surgical intervention based on an anatomic study.Ten fresh cadavers with large noses were used for the anatomic study. Between April 2008 and September 2010, 20 patients underwent surgical intervention for hyperactivated depressor septi nasi.In all of the cadaver dissections, the depressor septi nasi was present, although it was difficult to identify the muscle clearly in 6 of the cadavers. We found that the depressor septi nasi in the other 4 cadavers consisted of 3 fascicles. The medial fascicles were divided into superficial and deep fibers. Both the deep and superficial fibers were inserted into the dermocartilaginous ligament in the nearby nasal tip. After the superficial fibers were interdigitated with the orbicularis oris, they originated from the alveolar bone. The deep fibers originated at the anterior nasal spine. The intermediate fascicles inserted to the footplates of the medial crus and caudal septum. After interdigitating with the medial fascicles and orbicularis oris, they also originated from the alveolar bone. The drooping nasal tips were improved in all cases using an intranasal approach to manipulate the depressor septi nasi. No specific complication was seen. Surgical intervention of a hyperactivated depressor septi nasi using an intranasal approach was a useful method for correcting a drooping nasal tip.
NASA Astrophysics Data System (ADS)
Lewińska, Paulina; Matuła, Rafał; Dyczko, Artur
2018-01-01
Spoil tips are anthropogenic terrain structures built of leftover (coal) mining materials. They consist mostly of slate and sandstone or mudstone but also include coal and highly explosive coal dust. Coal soil tip fires cause an irreversible degradation to the environment. Government organizations notice the potential problem of spoil tip hazard and are looking for ways of fast monitoring of their temperature and inside structure. In order to test new monitoring methods an experimental was performed in the area of spoil tip of Lubelski Węgiel "Bogdanka" S.A. A survey consisted of creating a 3D discreet thermal model. This was done in order to look for potential fire areas. MASW (Multichannel analysis of surface wave) was done in order to find potential voids within the body of a tip. Existing data was digitalized and a 3D model of object's outside and inside was produced. This article provides results of this survey and informs about advantages of such an approach.
Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips
Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali
2016-01-01
Summary: Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable. PMID:27757342
Twelve tips for facilitating Millennials' learning.
Roberts, David H; Newman, Lori R; Schwartzstein, Richard M
2012-01-01
The current, so-called "Millennial" generation of learners is frequently characterized as having deep understanding of, and appreciation for, technology and social connectedness. This generation of learners has also been molded by a unique set of cultural influences that are essential for medical educators to consider in all aspects of their teaching, including curriculum design, student assessment, and interactions between faculty and learners. The following tips outline an approach to facilitating learning of our current generation of medical trainees. The method is based on the available literature and the authors' experiences with Millennial Learners in medical training. The 12 tips provide detailed approaches and specific strategies for understanding and engaging Millennial Learners and enhancing their learning. With an increased understanding of the characteristics of the current generation of medical trainees, faculty will be better able to facilitate learning and optimize interactions with Millennial Learners.
Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement.
Tacher, Vania; Petit, Arthur; Derbel, Haytham; Novelli, Luigi; Vitellius, Manuel; Ridouani, Fourat; Luciani, Alain; Rahmouni, Alain; Duvoux, Christophe; Salloum, Chady; Chiaradia, Mélanie; Kobeiter, Hicham
2017-11-01
To assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement. All consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated. Sixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm 2 , fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%). This study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.
Design Study of Propulsion and Drive Systems for the Large Civil TiltRotor (LCTR2) Rotorcraft
NASA Technical Reports Server (NTRS)
Robuck, Mark; Wilkerson, Joseph; Zhang, Yiyi; Snyder, Christopher A.; Vonderwell, Daniel
2013-01-01
Boeing, Rolls Royce, and NASA have worked together to complete a parametric sizing study for NASA's Large Civil Tilt Rotor (LCTR2) concept 2nd iteration. Vehicle gross weight and fuel usage were evaluated as propulsion and drive system characteristics were varied to maximize the benefit of reduced rotor tip speed during cruise conditions. The study examined different combinations of engine and gearbox variability to achieve rotor cruise tip speed reductions down to 54% of the hover tip speed. Previous NASA studies identified that a 54% rotor speed reduction in cruise minimizes vehicle gross weight and fuel burn. The LCTR2 was the study baseline for initial sizing. This study included rotor tip speed ratios (cruise to hover) of 100%, 77% and 54% at different combinations of engine RPM and gearbox speed reductions, which were analyzed to achieve the lightest overall vehicle gross weight (GW) at the chosen rotor tip speed ratio. Different engine and gearbox technology levels are applied ranging from commercial off-the-shelf (COTS) engines and gearbox technology to entry-in-service (EIS) dates of 2025 and 2035 to assess the benefits of advanced technology on vehicle gross weight and fuel burn. Interim results were previously reported1. This technical paper extends that work and summarizes the final study results including additional engine and drive system study accomplishments. New vehicle sizing data is presented for engine performance at a single operating speed with a multispeed drive system. Modeling details for LCTR2 vehicle sizing and subject engine and drive sub-systems are presented as well. This study was conducted in support of NASA's Fundamental Aeronautics Program, Subsonic Rotary Wing Project.
Chemical composition of felt-tip pen inks.
Germinario, Giulia; Garrappa, Silvia; D'Ambrosio, Valeria; van der Werf, Inez Dorothé; Sabbatini, Luigia
2018-01-01
Felt-tip pens are frequently used for the realization of sketches, drawings, architectural projects, and other technical designs. The formulations of these inks are usually rather complex and may be associated to those of modern paint materials where, next to the binding medium and pigments/dyes, solvents, fillers, emulsifiers, antioxidants, plasticizers, light stabilizers, biocides, and so on are commonly added. Felt-tip pen inks are extremely sensitive to degradation and especially exposure to light may cause chromatic changes and fading. In this study, we report on the complete chemical characterization of modern felt-tip pen inks that are commercially available and commonly used for the realization of artworks. Three brands of felt-tip pens (Faber-Castell, Edding, and Stabilo) were investigated with complementary analytical techniques such as thin-layer chromatography (TLC), VIS-reflectance spectroscopy, μ-Raman spectroscopy, surface-enhanced Raman spectroscopy (SERS), pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS), GC-MS, and Fourier transform infrared (FTIR) spectroscopy. The use of TLC proved to be very powerful in the study of complex mixtures of synthetic dyes. First derivatives of the reflectance spectra acquired on the TLC spots were useful in the preliminary identification of the dye, followed by Raman spectroscopy and SERS, which allowed for the unambiguous determination of the chemical composition of the pigments (phthalocyanines, dioxazines, and azo pigments) and dyes (azo dyes, triarylmethanes, xanthenes). FTIR spectroscopy was used especially for the detection of additives, as well as for confirming the nature of solvents and dyes/pigments. Finally, (Py-)GC-MS data provided information on the binders (styrene-acrylic resins, plant gums), solvents, and additives, as well as on pigments and dyes.
Takata, Hiroki; Naiki, Hiroyuki; Wang, Li; Fujiwara, Hideki; Sasaki, Keiji; Tamai, Naoto; Masuo, Sadahiro
2016-09-14
The enhancement of multiphoton emission from a single colloidal nanocrystal quantum dot (NQD) interacting with a plasmonic nanostructure was investigated using a silver-coated atomic force microscopy tip (AgTip) as the plasmonic nanostructure. Using the AgTip, which exhibited a well-defined localized surface plasmon (LSP) resonance band, we controlled the spectral overlap and the distance between the single NQD and the AgTip. The emission behavior of the single NQD when approaching the AgTip at the nanometer scale was measured using off-resonance (405 nm) and resonance (465 nm) excitation of the LSP. We directly observed the conversion of the single-photon emission from a single NQD to multiphoton emission with reduction of the emission lifetime at both excitation wavelengths as the NQD-AgTip distance decreased, whereas a decrease and increase in the emission intensity were observed at 405 and 465 nm excitation, respectively. By combining theoretical analysis and the numerical simulation of the AgTip, we deduced that the enhancement of the multiphoton emission was caused by the quenching of the single-exciton state due to the energy transfer from the NQD to the AgTip and that the emission intensity was increased by enhancement of the excitation rate due to the electric field of the LSP on the AgTip. These results provide evidence that the photon statistics and the photon flux from the single NQD can be manipulated by the plasmonic nanostructure through control of the spectral overlap and the distance.
The 30-kW ammonia arcjet technology
NASA Technical Reports Server (NTRS)
Deininger, W. D.; Chopra, A.; Pivirotto, T. J.; Goodfellow, K. D.; Barnett, J. W.
1990-01-01
The technical results are summarized of a 30 kW class ammonia propellant arcjet technology program. Evaluation of previous arcjet thruster performance, including materials analysis of used thruster components, led to the design of an arcjet with improved performance and thermal characteristics. Tests of the new engine demonstrated that engine performance is relatively insensitive to cathode tip geometry. Other data suggested a maximum sustainable arc length for a given thruster configuration, beyond which the arc may reconfigure in a destructive manner. A flow controller calibration error was identified. This error caused previously reported values of specific impulse and thrust efficiency to be 20 percent higher than the real values. Corrected arcjet performance data are given. Duration tests of 413 and 252 hours, and several tests 100 hours in duration, were performed. The cathode tip erosion rate increased with increasing arc current. Elimination of power source ripple did not affect cathode tip whisker growth. Results of arcjet modeling, diagnostic development and mission analyses are also discussed. The 30 kW ammonia arcjet may now be considered ready for development for a flight demonstration, but widespread application of 30 kW class arcjet will require improved efficiency and lifetime.
Yamamoto, Katsumi; Michida, Tomoki; Nishida, Tsutomu; Hayashi, Shiro; Naito, Masafumi; Ito, Toshifumi
2015-01-01
Endoscopic submucosal dissection (ESD) is very useful in en bloc resection of large superficial colorectal tumors but is a technically difficult procedure because the colonic wall is thin and endoscopic maneuverability is poor because of colonic flexure and extensibility. A high risk of perforation has been reported in colorectal ESD. To prevent complications such as perforation and unexpected bleeding, it is crucial to ensure good visualization of the submucosal layer by creating a mucosal flap, which is an exfoliated mucosa for inserting the tip of the endoscope under it. The creation of a mucosal flap is often technically difficult; however, various types of equipment, appropriate strategy, and novel procedures including our clip-flap method, appear to facilitate mucosal flap creation, improving the safety and success rate of ESD. Favorable treatment outcomes with colorectal ESD have already been reported in many advanced institutions, and appropriate understanding of techniques and development of training systems are required for world-wide standardization of colorectal ESD. Here, we describe recent technical advances for safe and successful colorectal ESD. PMID:26468335
Holographic studies of shock waves within transonic fan rotors
NASA Technical Reports Server (NTRS)
Benser, W. A.; Bailey, E. E.; Gelder, T. F.
1973-01-01
Pulsed laser holographic interferometry has been applied to the detection of shock patterns in the outer span regions of high tip speed transonic rotors. The first holographic approach used ruby laser light reflected from a portion of the centerbody just ahead of the rotor. These holograms showed the bow wave patterns upstream of the rotor and the shock patterns just inside the blade row near the tip. Much of the region of interest was in the shadow of the blade leading edge and could not be visualized. The second holographic approach, on a different rotor, used light transmitted diagonally across the inlet annulus past the centerbody. This approach gave a more extensive view of the region bounded by the blade leading and trailing edges, by the part span shroud and by the blade tip. These holograms showed the passage shock emanating from the blade leading edge and a moderately strong conical shock originating at the intersection of the part span shroud leading edge and the blade suction surface. Reasonable details of the shock patterns were obtained from holograms which were made without extensive rig modifications.
Surface modifications with Lissajous trajectories using atomic force microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Wei; Yao, Nan, E-mail: nyao@princeton.edu
2015-09-14
In this paper, we report a method for atomic force microscopy surface modifications with single-tone and multiple-resolution Lissajous trajectories. The tip mechanical scratching experiments with two series of Lissajous trajectories were carried out on monolayer films. The scratching processes with two scan methods have been illustrated. As an application, the tip-based triboelectrification phenomenon on the silicon dioxide surface with Lissajous trajectories was investigated. The triboelectric charges generated within the tip rubbed area on the surface were characterized in-situ by scanning Kelvin force microscopy. This method would provide a promising and cost-effective approach for surface modifications and nanofabrication.
NASA Astrophysics Data System (ADS)
Akıner, Tolga; Mason, Jeremy; Ertürk, Hakan
2017-11-01
The thermal properties of the TIP3P and TIP5P water models are investigated using equilibrium and non-equilibrium molecular dynamics techniques in the presence of solid surfaces. The performance of the non-equilibrium technique for rigid molecules is found to depend significantly on the distribution of atomic degrees of freedom. An improved approach to distribute atomic degrees of freedom is proposed for which the thermal conductivity of the TIP5P model agrees more closely with equilibrium molecular dynamics and experimental results than the existing state of the art.
Crises, noise, and tipping in the Hassell population model
NASA Astrophysics Data System (ADS)
Bashkirtseva, Irina
2018-03-01
We consider a problem of the analysis of the noise-induced tipping in population systems. To study this phenomenon, we use Hassell-type system with Allee effect as a conceptual model. A mathematical investigation of the tipping is connected with the analysis of the crisis bifurcations, both boundary and interior. In the parametric study of the abrupt changes in dynamics related to the noise-induced extinction and transition from order to chaos, the stochastic sensitivity function technique and confidence domains are used. The effectiveness of the suggested approach to detect early warnings of critical stochastic transitions is demonstrated.
NASA Astrophysics Data System (ADS)
Gersonius, Berry; Ashley, Richard; Jeuken, Ad; Nasruddin, Fauzy; Pathirana, Assela; Zevenbergen, Chris
2010-05-01
In a context of high uncertainty about hydrological variables due to climate change and other factors, the development of updated risk management approaches is as important as—if not more important than—the provision of improved data and forecasts of the future. Traditional approaches to adaptation attempt to manage future water risks to cities with the use of the predict-then-adapt method. This method uses hydrological change projections as the starting point to identify adaptive strategies, which is followed by analysing the cause-effect chain based on some sort of Pressures-State-Impact-Response (PSIR) scheme. The predict-then-adapt method presumes that it is possible to define a singular (optimal) adaptive strategy according to a most likely or average projection of future change. A key shortcoming of the method is, however, that the planning of water management structures is typically decoupled from forecast uncertainties and is, as such, inherently inflexible. This means that there is an increased risk of under- or over-adaptation, resulting in either mal-functioning or unnecessary costs. Rather than taking a traditional approach, responsible water risk management requires an alternative approach to adaptation that recognises and cultivates resiliency for change. The concept of resiliency relates to the capability of complex socio-technical systems to make aspirational levels of functioning attainable despite the occurrence of possible changes. Focusing on resiliency does not attempt to reduce uncertainty associated with future change, but rather to develop better ways of managing it. This makes it a particularly relevant perspective for adaptation to long-term hydrological change. Although resiliency is becoming more refined as a theory, the application of the concept to water risk management is still in an initial phase. Different methods are used in practice to support the implementation of a resilience-focused approach. Typically these approaches start the identification and analysis of adaptive strategies at the end of PSIR scheme: impact and examine whether, and for how long, current risk management strategies will continue to be effective under different future conditions. The most noteworthy application of this approach is the adaptation tipping point method. Adaptation tipping points (ATP) are defined as the points where the magnitude of change is such that the current risk management strategy can no longer meet its objectives. In the ATP method, policy objectives, determining aspirational functioning, are taken as the starting point. Also, the current measures to achieve these objectives are described. This is followed by a sensitivity analysis to determine the optimal and critical boundary conditions (state). Lastly, the state is related to pressures in terms of future change. It should be noted that in the ATP method the driver for adopting a new risk management strategy is not future change as such, but rather failing to meet the policy objectives. In the current paper, the ATP method is applied to the case study of an existing stormwater system in Dordrecht (the Netherlands). This application shows the potential of the ATP method to reduce the complexity of implementing a resilience-focused approach to water risk management. It is expected that this will help foster greater practical relevance of resilience as a perspective for the planning of water management structures.
NASA Astrophysics Data System (ADS)
Mönig, Harry; Amirjalayer, Saeed; Timmer, Alexander; Hu, Zhixin; Liu, Lacheng; Díaz Arado, Oscar; Cnudde, Marvin; Strassert, Cristian Alejandro; Ji, Wei; Rohlfing, Michael; Fuchs, Harald
2018-05-01
Atomic force microscopy is an impressive tool with which to directly resolve the bonding structure of organic compounds1-5. The methodology usually involves chemical passivation of the probe-tip termination by attaching single molecules or atoms such as CO or Xe (refs 1,6-9). However, these probe particles are only weakly connected to the metallic apex, which results in considerable dynamic deflection. This probe particle deflection leads to pronounced image distortions, systematic overestimation of bond lengths, and in some cases even spurious bond-like contrast features, thus inhibiting reliable data interpretation8-12. Recently, an alternative approach to tip passivation has been used in which slightly indenting a tip into oxidized copper substrates and subsequent contrast analysis allows for the verification of an oxygen-terminated Cu tip13-15. Here we show that, due to the covalently bound configuration of the terminal oxygen atom, this copper oxide tip (CuOx tip) has a high structural stability, allowing not only a quantitative determination of individual bond lengths and access to bond order effects, but also reliable intermolecular bond characterization. In particular, by removing the previous limitations of flexible probe particles, we are able to provide conclusive experimental evidence for an unusual intermolecular N-Au-N three-centre bond. Furthermore, we demonstrate that CuOx tips allow the characterization of the strength and configuration of individual hydrogen bonds within a molecular assembly.
Gallagher, Peter; Martin, Laura; Angel, Lori; Tomassoni, Gery
2007-02-01
The placement of left ventricular (LV) leads during cardiac resynchronization therapy (CRT) involves many technical difficulties. These difficulties increase procedural times and decrease procedural success rates. A total of 50 patients with severe cardiomyopathy (mean LV ejection fraction was 21 +/- 6%) and a wide QRS underwent CRT implantation. Magnetic navigation (Stereotaxis, Inc.) was used to position a magnet-tipped 0.014'' guidewire (Cronus guidewire) within the coronary sinus (CS) vasculature. LV leads were placed in a lateral CS branch, either using a standard CS delivery sheath or using a "bare-wire" approach without a CS delivery sheath. The mean total procedure time was 98.1 +/- 29.1 minutes with a mean fluoroscopy time of 22.7 +/- 15.1 minutes. The mean LV lead positioning time was 10.4 +/- 7.6 minutes. The use of a delivery sheath was associated with longer procedure times 98 +/- 32 minutes vs 80 +/- 18 minutes (P = 0.029), fluoroscopy times 23 +/- 15 minutes vs 13 +/- 4 minutes (P = 0.0007) and LV lead positioning times 10 +/- 6 minutes vs 4 +/- 2 minutes (P = 0.015) when compared to a "bare-wire" approach. When compared with 52 nonmagnetic-assisted control CRT cases, magnetic navigation reduced total LV lead positioning times (10.4 +/- 7.6 minutes vs 18.6 +/- 18.9 minutes; P = 0.005). If more than one CS branch vessel was tested, magnetic navigation was associated with significantly shorter times for LV lead placement (16.2 +/- 7.7 minutes vs 36.4 +/- 23.4 minutes; P = 0.004). Magnetic navigation is a safe, feasible, and efficient tool for lateral LV lead placement during CRT. Magnetic navigation during CRT allows for control of the tip direction of the Cronus 0.014'' guidewire using either a standard CS delivery sheath or "bare-wire" approach. Although there are some important limitations to the 0.014'' Cronus magnetic navigation can decrease LV lead placement times compared with nonmagnetic-assisted control CRT cases, particularly if multiple CS branches are to be tested.
Using Cascading Style Sheets to Design a Fly-Out Menu with Microsoft Visual Studio
ERIC Educational Resources Information Center
Liu, Chang; Downing, Charles
2010-01-01
The menu has become an integrated component within nearly all professionally designed websites. This teaching tip presents a no-code way to design either a vertical or a horizontal fly-out menu by using Cascading Style Sheets (CSS) within Microsoft Visual Studio 2008. The approach described in this tip helps students fully understand how to…
ERIC Educational Resources Information Center
Ogletree, August E.
2009-01-01
Two needs of Georgia State University Professional Development School Partnerships are to show increases in both student academic achievement and teacher efficacy. The Teacher-Intern-Professor (TIP) Model was designed to address these needs. The TIP model focuses on using the university and school partnership to support Georgia State University…
Orcutt, Sonia T.; Kobayashi, Katsuhiro; Sultenfuss, Mark; Hailey, Brian S.; Sparks, Anthony; Satpathy, Bighnesh; Anaya, Daniel A.
2016-01-01
Preoperative portal vein embolization (PVE) is used to extend the indications for major hepatic resection, and it has become the standard of care for selected patients with hepatic malignancies treated at major hepatobiliary centers. To date, various techniques with different embolic materials have been used with similar results in the degree of liver hypertrophy. Regardless of the specific strategy used, both surgeons and interventional radiologists must be familiar with each other’s techniques to be able to create the optimal plan for each individual patient. Knowledge of the segmental anatomy of the liver is paramount to fully understand the liver segments that need to be embolized and resected. Understanding the portal vein anatomy and the branching variations, along with the techniques used to transect the portal vein during hepatic resection, is important because these variables can affect the PVE procedure and the eventual surgical resection. Comprehension of the advantages and disadvantages of approaches to the portal venous system and the various embolic materials used for PVE is essential to best tailor the procedures for each patient and to avoid complications. Before PVE, meticulous assessment of the portal vein branching anatomy is performed with cross-sectional imaging, and embolization strategies are developed based on the patient’s anatomy. The PVE procedure consists of several technical steps, and knowledge of these technical tips, potential complications, and how to avoid the complications in each step is of great importance for safe and successful PVE and ultimately successful hepatectomy. Because PVE is used as an adjunct to planned hepatic resection, priority must always be placed on safety, without compromising the integrity of the future liver remnant, and close collaboration between interventional radiologists and hepatobiliary surgeons is essential to achieve successful outcomes. PMID:27014696
Novel fiber optic tip designs and devices for laser surgery
NASA Astrophysics Data System (ADS)
Hutchens, Thomas Clifton
Fiber optic delivery of laser energy has been used for years in various types of surgical procedures in the human body. Optical energy provides several benefits over electrical or mechanical surgery, including the ability to selectively target specific tissue types while preserving others. Specialty fiber optic tips have also been introduced to further customize delivery of laser energy to the tissue. Recent evolution in lasers and miniaturization has opened up opportunities for many novel surgical techniques. Currently, ophthalmic surgeons use relatively invasive mechanical tools to dissect retinal deposits which occur in proliferative diabetic retinopathy. By using the tight focusing properties of microspheres combined with the short optical penetration depth of the Erbium:YAG laser and mid-IR fiber delivery, a precise laser scalpel can be constructed as an alternative, less invasive and more precise approach to this surgery. Chains of microspheres may allow for a self limiting ablation depth of approximately 10 microm based on the defocusing of paraxial rays. The microsphere laser scalpel may also be integrated with other surgical instruments to reduce the total number of handpieces for the surgeon. In current clinical laser lithotripsy procedures, poor input coupling of the Holmium:YAG laser energy frequently damages and requires discarding of the optical fiber. However, recent stone ablation studies with the Thulium fiber laser have provided comparable results to the Ho:YAG laser. The improved spatial beam profile of the Thulium fiber laser can also be efficiently coupled into a fiber approximately one third the diameter and reduces the risk of damaging the fiber input. For this reason, the trunk optical fiber minus the distal fiber tip can be preserved between procedures. The distal fiber tip, which degrades during stone ablation, could be made detachable and disposable. A novel, low-profile, twist-locking, detachable distal fiber tip interface was designed, assembled, and tested for use in Thulium fiber laser lithotripsy. A 1.00-mm-outer-diameter detachable fiber tip interface was designed, constructed, and tested ex vivo on urinary stones in the laboratory. Similar stone ablation rates between the previously studied tapered distal fiber tip and the detachable fiber tip were measured. For urologists desiring faster TFL lithotripsy procedures, the incorporation of detachable distal fiber tips allows for rapid replacement of damaged fiber tips without concern about the laser to trunk fiber connection. This method for preserving the trunk fiber could be a motivation for integrating a dedicated laser fiber into the ureteroscope, with detachable distal tips, thus freeing the working channel for the use of other surgical instruments. During laser lithotripsy, distal fiber tip degradation increases as the fiber core diameter decreases. However, smaller fiber diameters (≤ 200 microm) are more desirable because of increased saline irrigation rates in the single working channel of the ureteroscope and less impact on ureteroscope deflection. A hollow fiber cap is proposed to reduced fiber tip degradation in small diameter fibers, without compromising stone ablation rates. The disadvantage of the hollow fiber tip observed in the study is the increase in stone retropulsion. However, integrating the hollow fiber tip with a clinically used stone basket may allow for a robust stone ablation instrument that also minimizes retropulsion. These surgical approaches involving novel specialty fiber optic tip designs are discussed in this thesis.
NASA Astrophysics Data System (ADS)
Popov, Igor; Đurišić, Ivana; Belić, Milivoj R.
2017-12-01
Engineering of materials at the atomic level is one of the most important aims of nanotechnology. The unprecedented ability of scanning probe microscopy to address individual atoms opened up the possibilities for nanomanipulation and nanolitography of surfaces and later on of two-dimensional materials. While the state-of-the-art scanning probe lithographic methods include, primarily, adsorption, desorption and repositioning of adatoms and molecules on substrates or tailoring nanoribbons by etching of trenches, the precise modification of the intrinsic atomic structure of materials is yet to be advanced. Here we introduce a new concept, scanning probe microscopy with a rotating tip, for engineering of the atomic structure of membranes based on two-dimensional materials. In order to indicate the viability of the concept, we present our theoretical research, which includes atomistic modeling, molecular dynamics simulations, Fourier analysis and electronic transport calculations. While stretching can be employed for fabrication of atomic chains only, our comprehensive molecular dynamics simulations indicate that nanomanipulation by scanning probe microscopy with a rotating tip is capable of assembling a wide range of topological defects in two-dimensional materials in a rather controllable and reproducible manner. We analyze two possibilities. In the first case the probe tip is retracted from the membrane while in the second case the tip is released beneath the membrane allowing graphene to freely relax and self-heal the pore made by the tip. The former approach with the tip rotation can be achieved experimentally by rotation of the sample, which is equivalent to rotation of the tip, whereas irradiation of the membrane by nanoclusters can be utilized for the latter approach. The latter one has the potential to yield a yet richer diversity of topological defects on account of a lesser determinacy. If successfully realized experimentally the concept proposed here could be an important step toward controllable nanostructuring of two-dimensional materials.
Popov, Igor; Đurišić, Ivana; Belić, Milivoj R
2017-12-08
Engineering of materials at the atomic level is one of the most important aims of nanotechnology. The unprecedented ability of scanning probe microscopy to address individual atoms opened up the possibilities for nanomanipulation and nanolitography of surfaces and later on of two-dimensional materials. While the state-of-the-art scanning probe lithographic methods include, primarily, adsorption, desorption and repositioning of adatoms and molecules on substrates or tailoring nanoribbons by etching of trenches, the precise modification of the intrinsic atomic structure of materials is yet to be advanced. Here we introduce a new concept, scanning probe microscopy with a rotating tip, for engineering of the atomic structure of membranes based on two-dimensional materials. In order to indicate the viability of the concept, we present our theoretical research, which includes atomistic modeling, molecular dynamics simulations, Fourier analysis and electronic transport calculations. While stretching can be employed for fabrication of atomic chains only, our comprehensive molecular dynamics simulations indicate that nanomanipulation by scanning probe microscopy with a rotating tip is capable of assembling a wide range of topological defects in two-dimensional materials in a rather controllable and reproducible manner. We analyze two possibilities. In the first case the probe tip is retracted from the membrane while in the second case the tip is released beneath the membrane allowing graphene to freely relax and self-heal the pore made by the tip. The former approach with the tip rotation can be achieved experimentally by rotation of the sample, which is equivalent to rotation of the tip, whereas irradiation of the membrane by nanoclusters can be utilized for the latter approach. The latter one has the potential to yield a yet richer diversity of topological defects on account of a lesser determinacy. If successfully realized experimentally the concept proposed here could be an important step toward controllable nanostructuring of two-dimensional materials.
Basaltic Dike Propagation at Yucca Mountain, Nevada, USA
NASA Astrophysics Data System (ADS)
Gaffney, E. S.; Damjanac, B.; Warpinski, N. R.
2004-12-01
We describe simulations of the propagation of basaltic dikes using a 2-dimensional, incompressible hydrofracture code including the effects of the free surface with specific application to potential interactions of rising magma with a nuclear waste repository at Yucca Mountain, Nevada. As the leading edge of the dike approaches the free surface, confinement at the crack tip is reduced and the tip accelerates relative to the magma front. In the absence of either excess confining stress or excess gas pressure in the tip cavity, this leads to an increase of crack-tip velocity by more than an order of magnitude. By casting the results in nondimensional form, they can be applied to a wide variety of intrusive situations. When applied to an alkali basalt intrusion at the proposed high-level nuclear waste repository at Yucca Mountain, the results provide for a description of the subsurface phenomena. For magma rising at 1 m/s and dikes wider than about 0.5 m, the tip of the fissure would already have breached the surface by the time magma arrived at the nominal 300-m repository depth. An approximation of the effect of magma expansion on dike propagation is used to show that removing the restriction of an incompressible magma would result in even greater crack-tip acceleration as the dike approached the surface. A second analysis with a distinct element code indicates that a dike could penetrate the repository even during the first 2000 years after closure during which time heating from radioactive decay of waste would raise the minimum horizontal compressive stress above the vertical stress for about 80 m above and below the repository horizon. Rather than sill formation, the analysis indicates that increased pressure and dike width below the repository cause the crack tip to penetrate the horizon, but much more slowly than under in situ stress conditions. The analysis did not address the effects of either anisotropic joints or heat loss on this result.
A high precision extrapolation method in multiphase-field model for simulating dendrite growth
NASA Astrophysics Data System (ADS)
Yang, Cong; Xu, Qingyan; Liu, Baicheng
2018-05-01
The phase-field method coupling with thermodynamic data has become a trend for predicting the microstructure formation in technical alloys. Nevertheless, the frequent access to thermodynamic database and calculation of local equilibrium conditions can be time intensive. The extrapolation methods, which are derived based on Taylor expansion, can provide approximation results with a high computational efficiency, and have been proven successful in applications. This paper presents a high precision second order extrapolation method for calculating the driving force in phase transformation. To obtain the phase compositions, different methods in solving the quasi-equilibrium condition are tested, and the M-slope approach is chosen for its best accuracy. The developed second order extrapolation method along with the M-slope approach and the first order extrapolation method are applied to simulate dendrite growth in a Ni-Al-Cr ternary alloy. The results of the extrapolation methods are compared with the exact solution with respect to the composition profile and dendrite tip position, which demonstrate the high precision and efficiency of the newly developed algorithm. To accelerate the phase-field and extrapolation computation, the graphic processing unit (GPU) based parallel computing scheme is developed. The application to large-scale simulation of multi-dendrite growth in an isothermal cross-section has demonstrated the ability of the developed GPU-accelerated second order extrapolation approach for multiphase-field model.
Dependence of the ferroelectric domain shape on the electric field of the microscope tip
DOE Office of Scientific and Technical Information (OSTI.GOV)
Starkov, Alexander S.; Starkov, Ivan A., E-mail: starkov@feec.vutbr.cz
2015-08-21
A theory of an equilibrium shape of the domain formed in an electric field of a scanning force microscope (SFM) tip is proposed. We do not assume a priori that the domain has a fixed form. The shape of the domain is defined by the minimum of the free energy of the ferroelectric. This energy includes the energy of the depolarization field, the energy of the domain wall, and the energy of the interaction between the domain and the electric field of the SFM tip. The contributions of the apex and conical part of the tip are examined. Moreover, inmore » the proposed approach, any narrow tip can be considered. The surface energy is determined on the basis of the Ginzburg-Landau-Devonshire theory and takes into account the curvature of the domain wall. The variation of the free energy with respect to the domain shape leads to an integro-differential equation, which must be solved numerically. Model results are illustrated for lithium tantalate ceramics.« less
Origin choice and petal loss in the flower garden of spiral wave tip trajectories
Gray, Richard A.; Wikswo, John P.; Otani, Niels F.
2009-01-01
Rotating spiral waves have been observed in numerous biological and physical systems. These spiral waves can be stationary, meander, or even degenerate into multiple unstable rotating waves. The spatiotemporal behavior of spiral waves has been extensively quantified by tracking spiral wave tip trajectories. However, the precise methodology of identifying the spiral wave tip and its influence on the specific patterns of behavior remains a largely unexplored topic of research. Here we use a two-state variable FitzHugh–Nagumo model to simulate stationary and meandering spiral waves and examine the spatiotemporal representation of the system’s state variables in both the real (i.e., physical) and state spaces. We show that mapping between these two spaces provides a method to demarcate the spiral wave tip as the center of rotation of the solution to the underlying nonlinear partial differential equations. This approach leads to the simplest tip trajectories by eliminating portions resulting from the rotational component of the spiral wave. PMID:19791998
Origin choice and petal loss in the flower garden of spiral wave tip trajectories.
Gray, Richard A; Wikswo, John P; Otani, Niels F
2009-09-01
Rotating spiral waves have been observed in numerous biological and physical systems. These spiral waves can be stationary, meander, or even degenerate into multiple unstable rotating waves. The spatiotemporal behavior of spiral waves has been extensively quantified by tracking spiral wave tip trajectories. However, the precise methodology of identifying the spiral wave tip and its influence on the specific patterns of behavior remains a largely unexplored topic of research. Here we use a two-state variable FitzHugh-Nagumo model to simulate stationary and meandering spiral waves and examine the spatiotemporal representation of the system's state variables in both the real (i.e., physical) and state spaces. We show that mapping between these two spaces provides a method to demarcate the spiral wave tip as the center of rotation of the solution to the underlying nonlinear partial differential equations. This approach leads to the simplest tip trajectories by eliminating portions resulting from the rotational component of the spiral wave.
Modern Protection Against Lightning Strikes
NASA Astrophysics Data System (ADS)
Moore, C.
2005-05-01
The application of science to provide protection against lightning strikes began around 1750 when Benjamin Franklin who invented the lightning rod in an effort to discharge thunderclouds. Instead of preventing lightning as he expected, his rods have been quite successful as strike receptors, intercepting cloud-to ground discharges and conducting them to Earth without damage to the structures on which they are mounted. In the years since Franklin's invention there has been little attention paid to the rod configuration that best serves as a strike receptor but Franklin's original ideas continue to be rediscovered and promoted. Recent measurements of the responses of variously configured rods to nearby strikes indicate that sharp-tipped rods are not the optimum configuration to serve as strike receptors since the ionization of the air around their tips limits the strength of the local electric fields created by an approaching lightning leader. In these experiments, fourteen blunt-tipped rods exposed in strike-reception competitions with nearby sharp-tipped rods were struck by lightning but none of the sharp-tipped rods were struck.
Trials of Improved Practices (TIPs): A Strategy for Making Long-Lasting Nets Last Longer?
Harvey, Steven A.; Paredes Olórtegui, Maribel; Leontsini, Elli; Ramal Asayag, César; Scott, Kerry; Winch, Peter J.
2013-01-01
Long-lasting insecticidal net (LLIN) use is a proven malaria prevention method. Mass distribution has greatly expanded LLIN access in sub-Saharan Africa, but a gap remains between LLIN ownership and use. Furthermore, LLINs wear out more quickly than anticipated. This paper suggests a participatory research strategy—trials of improved practices (TIPs)—that could identify locally appropriate approaches to prolonging net life and increasing effective use. We used TIPs to overcome barriers to optimal net use in the Peruvian Amazon. Working with 15 families in three villages, we tested home treatment of cotton nets, use of an alternative netting fabric, and alternative washing and care instructions. TIPs helped confirm feasibility of these interventions. Although our findings are time- and context-specific, TIPs could help improve consistency and effectiveness of current LLIN use and prolong net lifespan in sub-Saharan Africa and elsewhere. This would help maximize the value of shrinking donor resources for malaria. PMID:23530074
A Complex Network Perspective on Clinical Science
Hofmann, Stefan G.; Curtiss, Joshua; McNally, Richard J.
2016-01-01
Contemporary classification systems for mental disorders assume that abnormal behaviors are expressions of latent disease entities. An alternative to the latent disease model is the complex network approach. Instead of assuming that symptoms arise from an underlying disease entity, the complex network approach holds that disorders exist as systems of interrelated elements of a network. This approach also provides a framework for the understanding of therapeutic change. Depending on the structure of the network, change can occur abruptly once the network reaches a critical threshold (the tipping point). Homogeneous and highly connected networks often recover more slowly from local perturbations when the network approaches the tipping point, allowing for the possibility to predict treatment change, relapse, and recovery. In this article we discuss the complex network approach as an alternative to the latent disease model, and we discuss its implications for classification, therapy, relapse, and recovery. PMID:27694457
[Detection of single-walled carbon nanotube bundles by tip-enhanced Raman spectroscopy].
Wu, Xiao-Bin; Wang, Jia; Wang, Rui; Xu, Ji-Ying; Tian, Qian; Yu, Jian-Yuan
2009-10-01
Raman spectroscopy is a powerful technique in the characterization of carbon nanotubes (CNTs). However, this spectral method is subject to two obstacles. One is spatial resolution, namely the diffraction limits of light, and the other is its inherent small Raman cross section and weak signal. To resolve these problems, a new approach has been developed, denoted tip-enhanced Raman spectroscopy (TERS). TERS has been demonstrated to be a powerful spectroscopic and microscopic technique to characterize nanomaterial or nanostructures. Excited by a focused laser beam, an enhanced electric field is generated in the vicinity of a metallic tip because of the surface plasmon polariton (SPP) and lightening rod effect. Consequently, Raman signal from the sample area illuminated by the enhanced field nearby the tip is enhanced. At the same time, the topography is obtained in the nanometer scale. The exact corresponding relationship between the localized Raman and the topography makes the Raman identification at the nanometer scale to be feasible. In the present paper, based on an inverted microscope and a metallic AFM tip, a tip-enhanced Raman system was set up. The radius of the Au-coated metallic tip is about 30 nm. The 532 nm laser passes through a high numerical objective (NA0.95) from the bottom to illuminate the tip to excite the enhanced electric field. Corresponding with the AFM image, the tip-enhanced near-field Raman of a 100 nm diameter single-walled carbon nanotube (SWNT) bundles was obtained. The SWNTs were prepared by arc method. Furthermore, the near-field Raman of about 3 SWNTs of the bundles was received with the spatial resolution beyond the diffraction limit. Compared with the far-field Raman, the enhancement factor of the tip-enhanced Raman is more than 230. With the super-diffraction spatial resolution and the tip-enhanced Raman ability, tip-enhanced Raman spectroscopy will play an important role in the nano-material and nano-structure characterization.
Computational Investigation of Novel Tip Leakage Mitigation Methods for High Pressure Turbine Blades
NASA Technical Reports Server (NTRS)
Ibrahim, Mounir; Gupta, Abhinav; Shyam, Vikram
2014-01-01
This paper presents preliminary findings on a possible approach to reducing tip leakage losses. In this paper a computational study was conducted on the Energy Efficient Engine (EEE) High Pressure Turbine (HPT) rotor tip geometry using the commercial numerical solver ANSYS FLUENT. The flow solver was validated against aerodynamic data acquired in the NASA Transonic Turbine Blade Cascade facility. The scope of the ongoing study is to computationally investigate how the tip leakage and overall blade losses are affected by (1) injection from the tip near the pressure side, (2) injection from the tip surface at the camber line, and (3) injection from the tip surface into the tip separation bubble. The objective is to identify the locations on the tip surface at which to place appropriately configured blowing keeping in mind the film cooling application of tip blowing holes. The validation was conducted at Reynolds numbers of 85,000, 343,000, and 685,000 and at engine realistic flow conditions. The coolant injection simulations were conducted at a Reynolds number of 343,000 based on blade chord and inlet velocity and utilized the SST turbulence model in FLUENT. The key parameters examined are the number of jets, jet angle and jet location. A coolant to inlet pressure ratio of 1.0 was studied for angles of +30 deg, -30 deg, and 90 deg to the local free stream on the tip. For the 3 hole configuration, 3 holes spaced 3 hole diameters apart with length to diameter ratio of 1.5 were used. A simulation including 11 holes along the entire mean camber line is also presented (30 deg toward suction side). In addition, the effect of a single hole is also compared to a flat tip with no injection. The results provide insight into tip flow control methods and can be used to guide further investigation into tip flow control. As noted in past research it is concluded that reducing leakage flow is not necessarily synonymous with reducing losses due to leakage.
Computational Investigation of Novel Tip Leakage Mitigation Methods for High Pressure Turbine Blades
NASA Technical Reports Server (NTRS)
Ibrahim, Mounir; Gupta, Abhinav; Shyam, Vikram
2014-01-01
This paper presents preliminary findings on a possible approach to reducing tip leakage losses. In this paper a computational study was conducted on the EEE (Energy Efficient Engine) HPT (High Pressure Turbine) rotor tip geometry using the commercial numerical solver ANSYS FLUENT. The flow solver was validated against aerodynamic data acquired in the NASA Transonic Turbine Blade Cascade facility. The scope of the ongoing study is to computationally investigate how the tip leakage and overall blade losses are affected by 1. injection from the tip near the pressure side, 2. injection from the tip surface at the camber line, and 3. injection from the tip surface into the tip separation bubble. The objective is to identify the locations on the tip surface at which to place appropriately configured blowing keeping in mind the film cooling application of tip blowing holes. The validation was conducted at Reynolds numbers of 85,000, 343,000 and 685,000 and at engine realistic flow conditions. The coolant injection simulations were conducted at a Reynolds number of 343,000 based on blade chord and inlet velocity and utilized the SST turbulence model in FLUENT. The key parameters examined are the number of jets, jet angle and jet location. A coolant to inlet pressure ratio of 1.0 was studied for angles of +30 deg., -30 deg. and 90 deg. to the local free stream on the tip. For the 3 hole configuration, 3 holes spaced 3 hole diameters apart with length to diameter ratio of 1.5 were used. A simulation including 11 holes along the entire mean camber line is also presented (30 degrees toward suction side). In addition, the effect of a single hole is also compared to a flat tip with no injection. The results provide insight into tip flow control methods and can be used to guide further investigation into tip flow control. As noted in past research it is concluded that reducing leakage flow is not necessarily synonymous with reducing losses due to leakage.
Mishra, Sundeep
The scientific discourse of chronic total occlusions interventions is mired in a technical jargon so confusing that it prevents an average interventional cardiologist from pursuing this field so much so that it has become a domain of a few. This review attempts to simplify this vernacular and present it in a manner that this procedure comes within the scope of a mainstream interventionist. Copyright © 2017. Published by Elsevier B.V.
Proto-Flight Manipulator Arm (P-FMA)
NASA Technical Reports Server (NTRS)
Britton, W. R.
1977-01-01
The technical development of the Proto-Flight Manipulator Arm (P-FMA) which is a seven-degree-of-freedom general-purpose arm capable of being remotely operated in an earth orbital environment is discussed. The P-FMA is a unique manipulator, combining the capabilities of significant dexterity, high tip forces, precise motion control, gear backdriveability, high end effector grip forces and torques, and the quality of flightworthiness. The 2.4-meter (8-foot) arm weighs 52.2 kilograms (115 pounds).
NASA Astrophysics Data System (ADS)
Tung, Yen-Chun; Chung, Ming-Han; Sung, I.-Hui; Lee, Chih-Kung
2014-03-01
Adopting optical technique to pursue micromachining must make a compromise between the focal spot sizes the depth of focus. The focal spot size determines the minimum features can be fabricated. On the other hand, the depth of focus influences the ease of alignment in positioning the fabrication light beam. A typical approach to bypass the diffraction limit is to adopt the near-field approach, which has spot size in the range of the optical fiber tip. However, the depth of focus of the emitted light beam will be limited to tens of nanometers in most cases, which posts a difficult challenge to control the distance between the optical fiber tip and the sample to be machined optically. More specifically, problems remained in this machining approach, which include issues such as residue induced by laser ablation tends to deposit near the optical fiber tip and leads to loss of coupling efficiency. We proposed a method based on illuminating femtosecond laser through a sub-wavelength annular aperture on metallic film so as to produce Bessel light beam of sub-wavelength while maintaining large depth of focus first. To further advance the ease of use in one such system, producing sub-wavelength annular aperture on a single mode optical fiber head with sub-wavelength focusing ability is detailed. It is shown that this method can be applied in material machining with an emphasis to produce high aspect ratio structure. Simulations and experimental results are presented in this paper.
NASA Astrophysics Data System (ADS)
Legleiter, Justin; Park, Matthew; Cusick, Brian; Kowalewski, Tomasz
2006-03-01
One of the major thrusts in proximal probe techniques is combination of imaging capabilities with simultaneous measurements of physical properties. In tapping mode atomic force microscopy (TMAFM), the most straightforward way to accomplish this goal is to reconstruct the time-resolved force interaction between the tip and surface. These tip-sample forces can be used to detect interactions (e.g., binding sites) and map material properties with nanoscale spatial resolution. Here, we describe a previously unreported approach, which we refer to as scanning probe acceleration microscopy (SPAM), in which the TMAFM cantilever acts as an accelerometer to extract tip-sample forces during imaging. This method utilizes the second derivative of the deflection signal to recover the tip acceleration trajectory. The challenge in such an approach is that with real, noisy data, the second derivative of the signal is strongly dominated by the noise. This problem is solved by taking advantage of the fact that most of the information about the deflection trajectory is contained in the higher harmonics, making it possible to filter the signal by “comb” filtering, i.e., by taking its Fourier transform and inverting it while selectively retaining only the intensities at integer harmonic frequencies. Such a comb filtering method works particularly well in fluid TMAFM because of the highly distorted character of the deflection signal. Numerical simulations and in situ TMAFM experiments on supported lipid bilayer patches on mica are reported to demonstrate the validity of this approach.
Spectral signatures of viewing a needle approaching one's body when anticipating pain.
Höfle, Marion; Pomper, Ulrich; Hauck, Michael; Engel, Andreas K; Senkowski, Daniel
2013-10-01
When viewing the needle of a syringe approaching your skin, anticipation of a painful prick may lead to increased arousal. How this anticipation is reflected in neural oscillatory activity and how it relates to activity within the autonomic nervous system is thus far unknown. Recently, we found that viewing needle pricks compared with Q-tip touches increases the pupil dilation response (PDR) and perceived unpleasantness of electrical stimuli. Here, we used high-density electroencephalography to investigate whether anticipatory oscillatory activity predicts the unpleasantness of electrical stimuli and PDR while viewing a needle approaching a hand that is perceived as one's own. We presented video clips of needle pricks and Q-tip touches, and delivered spatiotemporally aligned painful and nonpainful intracutaneous electrical stimuli. The perceived unpleasantness of electrical stimuli and the PDR were enhanced when participants viewed needle pricks compared with Q-tip touches. Source reconstruction using linear beamforming revealed reduced alpha-band activity in the posterior cingulate cortex (PCC) and fusiform gyrus before the onset of electrical stimuli when participants viewed needle pricks compared with Q-tip touches. Moreover, alpha-band activity in the PCC predicted PDR on a single trial level. The anticipatory reduction of alpha-band activity in the PCC may reflect a neural mechanism that serves to protect the body from forthcoming harm by facilitating the preparation of adequate defense responses. © 2013 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Arcila, Dahiana; Alexander Pyron, R; Tyler, James C; Ortí, Guillermo; Betancur-R, Ricardo
2015-01-01
Time-calibrated phylogenies based on molecular data provide a framework for comparative studies. Calibration methods to combine fossil information with molecular phylogenies are, however, under active development, often generating disagreement about the best way to incorporate paleontological data into these analyses. This study provides an empirical comparison of the most widely used approach based on node-dating priors for relaxed clocks implemented in the programs BEAST and MrBayes, with two recently proposed improvements: one using a new fossilized birth-death process model for node dating (implemented in the program DPPDiv), and the other using a total-evidence or tip-dating method (implemented in MrBayes and BEAST). These methods are applied herein to tetraodontiform fishes, a diverse group of living and extinct taxa that features one of the most extensive fossil records among teleosts. Previous estimates of time-calibrated phylogenies of tetraodontiforms using node-dating methods reported disparate estimates for their age of origin, ranging from the late Jurassic to the early Paleocene (ca. 150-59Ma). We analyzed a comprehensive dataset with 16 loci and 210 morphological characters, including 131 taxa (95 extant and 36 fossil species) representing all families of fossil and extant tetraodontiforms, under different molecular clock calibration approaches. Results from node-dating methods produced consistently younger ages than the tip-dating approaches. The older ages inferred by tip dating imply an unlikely early-late Jurassic (ca. 185-119Ma) origin for this order and the existence of extended ghost lineages in their fossil record. Node-based methods, by contrast, produce time estimates that are more consistent with the stratigraphic record, suggesting a late Cretaceous (ca. 86-96Ma) origin. We show that the precision of clade age estimates using tip dating increases with the number of fossils analyzed and with the proximity of fossil taxa to the node under assessment. This study suggests that current implementations of tip dating may overestimate ages of divergence in calibrated phylogenies. It also provides a comprehensive phylogenetic framework for tetraodontiform systematics and future comparative studies. Copyright © 2014 Elsevier Inc. All rights reserved.
Stiffness Control of Surgical Continuum Manipulators
Mahvash, Mohsen; Dupont, Pierre E.
2013-01-01
This paper introduces the first stiffness controller for continuum robots. The control law is based on an accurate approximation of a continuum robot’s coupled kinematic and static force model. To implement a desired tip stiffness, the controller drives the actuators to positions corresponding to a deflected robot configuration that produces the required tip force for the measured tip position. This approach provides several important advantages. First, it enables the use of robot deflection sensing as a means to both sense and control tip forces. Second, it enables stiffness control to be implemented by modification of existing continuum robot position controllers. The proposed controller is demonstrated experimentally in the context of a concentric tube robot. Results show that the stiffness controller achieves the desired stiffness in steady state, provides good dynamic performance, and exhibits stability during contact transitions. PMID:24273466
Twelve tips for applying change models to curriculum design, development and delivery.
McKimm, Judy; Jones, Paul Kneath
2017-10-25
Drawing primarily from business and management literature and the authors' experience, these 12 tips provide guidance to organizations, teams, and individuals involved in curriculum or program development at undergraduate, postgraduate, and continuing education levels. The tips are based around change models and approaches and can help underpin successful curriculum review, development, and delivery, as well as fostering appropriate educational innovation. A range of tools exist to support systematic program development and review, but even relatively simple changes need to take account of many factors, including the complexity of the environment, stakeholder engagement, cultural and psychological aspects, and the importance of followers.
Jin, Bo; Zhang, Weifang; Zhang, Meng; Ren, Feifei; Dai, Wei; Wang, Yanrong
2017-01-01
In order to monitor the crack tip propagation of aluminum alloy, this study investigates the variation of the spectrum characteristics of a fiber Bragg grating (FBG), combined with an analysis of the spectrum simulation. The results identify the location of the subordinate peak as significantly associated with the strain distribution along the grating, corresponding to the different plastic zones ahead of the crack tip with various crack lengths. FBG sensors could observe monotonic and cyclic plastic zones ahead of the crack tip, with the quadratic strain distribution along the grating at the crack tip-FBG distance of 1.2 and 0.7 mm, respectively. FBG sensors could examine the process zones ahead of the crack tip with the cubic strain distribution along the grating at the crack tip-FBG distance of 0.5 mm. The spectrum oscillation occurs as the crack approaches the FBG where the highly heterogeneous strain is distributed. Another idea is to use a finite element method (FEM), together with a T-matrix method, to analyze the reflection intensity spectra of FBG sensors for various crack sizes. The described crack propagation detection system may apply in structural health monitoring. PMID:28772949
Jin, Bo; Zhang, Weifang; Zhang, Meng; Ren, Feifei; Dai, Wei; Wang, Yanrong
2017-05-27
In order to monitor the crack tip propagation of aluminum alloy, this study investigates the variation of the spectrum characteristics of a fiber Bragg grating (FBG), combined with an analysis of the spectrum simulation. The results identify the location of the subordinate peak as significantly associated with the strain distribution along the grating, corresponding to the different plastic zones ahead of the crack tip with various crack lengths. FBG sensors could observe monotonic and cyclic plastic zones ahead of the crack tip, with the quadratic strain distribution along the grating at the crack tip-FBG distance of 1.2 and 0.7 mm, respectively. FBG sensors could examine the process zones ahead of the crack tip with the cubic strain distribution along the grating at the crack tip-FBG distance of 0.5 mm. The spectrum oscillation occurs as the crack approaches the FBG where the highly heterogeneous strain is distributed. Another idea is to use a finite element method (FEM), together with a T -matrix method, to analyze the reflection intensity spectra of FBG sensors for various crack sizes. The described crack propagation detection system may apply in structural health monitoring.
Attachment of Single Multiwall WS2 Nanotubes and Single WO3-x Nanowhiskers to a Probe
NASA Astrophysics Data System (ADS)
Ashiri, I.; Gartsman, K.; Cohen, S. R.; Tenne, R.
2003-10-01
WS2 nanotubes were the first inorganic fullerene-like (IF) structures to be synthesized. Although the physical properties of IF were not fully studied it seems that the WS2 nanotubes can be suitable for applications in the nanoscale range. An approach toward nanofabrication is simulated in this study. High resolution scanning electron microscope equipped with micromanipulator was used to attach single multiwall WS2 nanotubes and single WO3-x nanowhiskers to a probe, which is an atomic force microscope (AFM) silicon tip in the present case. The imaging capabilities of this nanotube or nanowhisker tip were tested in the AFM. The WO3-x nanowhisker tip was found to be stable, but it has a low lateral resolution (100nm). The WS2 nanotube tips were found to be stable only when its length was smaller than 1 μm. The fabrication technique of WS2 nanotube tip and WO3-x nanowhisker tip was found to be controllable and reliable and it can probably be used to various applications as well as for preparation of single nanotubes samples for measurements, like mechanical or optical probes.
Coherent dynamics in the rotor tip shear layer of utility-scale wind turbines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xiaolei; Hong, Jiarong; Barone, Matthew
Here, recent field experiments conducted in the near wake (up to 0.5 rotor diameters downwind of the rotor) of a Clipper Liberty C96 2.5 MW wind turbine using snow-based super-large-scale particle image velocimetry (SLPIV) were successful in visualizing tip vortex cores as areas devoid of snowflakes. The so-visualized snow voids, however, suggested tip vortex cores of complex shape consisting of circular cores with distinct elongated comet-like tails. We employ large-eddy simulation (LES) to elucidate the structure and dynamics of the complex tip vortices identified experimentally. We show that the LES, with inflow conditions representing as closely as possible the statemore » of the flow approaching the turbine when the SLPIV experiments were carried out, reproduce vortex cores in good qualitative agreement with the SLPIV results, essentially capturing all vortex core patterns observed in the field in the tip shear layer. The computed results show that the visualized vortex patterns are formed by the tip vortices and a second set of counter-rotating spiral vortices intertwined with the tip vortices. To probe the dependence of these newly uncovered coherent flow structures on turbine design, size and approach flow conditions, we carry out LES for three additional turbines: (i) the Scaled Wind Farm Technology (SWiFT) turbine developed by Sandia National Laboratories in Lubbock, TX, USA; (ii) the wind turbine developed for the European collaborative MEXICO (Model Experiments in Controlled Conditions) project; and (iii) the model turbine, and the Clipper turbine under varying inflow turbulence conditions. We show that similar counter-rotating vortex structures as those observed for the Clipper turbine are also observed for the SWiFT, MEXICO and model wind turbines. However, the strength of the counter-rotating vortices relative to that of the tip vortices from the model turbine is significantly weaker. We also show that incoming flows with low level turbulence attenuate the elongation of the tip and counter-rotating vortices. Sufficiently high turbulence levels in the incoming flow, on the other hand, tend to break up the coherence of spiral vortices in the near wake. To elucidate the physical mechanism that gives rise to such rich coherent dynamics we examine the stability of the turbine tip shear layer using the theory. We show that for all simulated cases the theory consistently indicates the flow to be unstable exactly in the region where counter-rotating spirals emerge. We thus postulate that centrifugal instability of the rotating turbine tip shear layer is a possible mechanism for explaining the phenomena we have uncovered herein.« less
Coherent dynamics in the rotor tip shear layer of utility-scale wind turbines
Yang, Xiaolei; Hong, Jiarong; Barone, Matthew; ...
2016-09-08
Here, recent field experiments conducted in the near wake (up to 0.5 rotor diameters downwind of the rotor) of a Clipper Liberty C96 2.5 MW wind turbine using snow-based super-large-scale particle image velocimetry (SLPIV) were successful in visualizing tip vortex cores as areas devoid of snowflakes. The so-visualized snow voids, however, suggested tip vortex cores of complex shape consisting of circular cores with distinct elongated comet-like tails. We employ large-eddy simulation (LES) to elucidate the structure and dynamics of the complex tip vortices identified experimentally. We show that the LES, with inflow conditions representing as closely as possible the statemore » of the flow approaching the turbine when the SLPIV experiments were carried out, reproduce vortex cores in good qualitative agreement with the SLPIV results, essentially capturing all vortex core patterns observed in the field in the tip shear layer. The computed results show that the visualized vortex patterns are formed by the tip vortices and a second set of counter-rotating spiral vortices intertwined with the tip vortices. To probe the dependence of these newly uncovered coherent flow structures on turbine design, size and approach flow conditions, we carry out LES for three additional turbines: (i) the Scaled Wind Farm Technology (SWiFT) turbine developed by Sandia National Laboratories in Lubbock, TX, USA; (ii) the wind turbine developed for the European collaborative MEXICO (Model Experiments in Controlled Conditions) project; and (iii) the model turbine, and the Clipper turbine under varying inflow turbulence conditions. We show that similar counter-rotating vortex structures as those observed for the Clipper turbine are also observed for the SWiFT, MEXICO and model wind turbines. However, the strength of the counter-rotating vortices relative to that of the tip vortices from the model turbine is significantly weaker. We also show that incoming flows with low level turbulence attenuate the elongation of the tip and counter-rotating vortices. Sufficiently high turbulence levels in the incoming flow, on the other hand, tend to break up the coherence of spiral vortices in the near wake. To elucidate the physical mechanism that gives rise to such rich coherent dynamics we examine the stability of the turbine tip shear layer using the theory. We show that for all simulated cases the theory consistently indicates the flow to be unstable exactly in the region where counter-rotating spirals emerge. We thus postulate that centrifugal instability of the rotating turbine tip shear layer is a possible mechanism for explaining the phenomena we have uncovered herein.« less
Pirooznia, Sheila K.; Chiu, Kellie; Chan, May T.; Zimmerman, John E.; Elefant, Felice
2012-01-01
Tip60 is a histone acetyltransferase (HAT) enzyme that epigenetically regulates genes enriched for neuronal functions through interaction with the amyloid precursor protein (APP) intracellular domain. However, whether Tip60-mediated epigenetic dysregulation affects specific neuronal processes in vivo and contributes to neurodegeneration remains unclear. Here, we show that Tip60 HAT activity mediates axonal growth of the Drosophila pacemaker cells, termed “small ventrolateral neurons” (sLNvs), and their production of the neuropeptide pigment-dispersing factor (PDF) that functions to stabilize Drosophila sleep–wake cycles. Using genetic approaches, we show that loss of Tip60 HAT activity in the presence of the Alzheimer’s disease-associated APP affects PDF expression and causes retraction of the sLNv synaptic arbor required for presynaptic release of PDF. Functional consequence of these effects is evidenced by disruption of the sleep–wake cycle in these flies. Notably, overexpression of Tip60 in conjunction with APP rescues these sleep–wake disturbances by inducing overelaboration of the sLNv synaptic terminals and increasing PDF levels, supporting a neuroprotective role for dTip60 in sLNv growth and function under APP-induced neurodegenerative conditions. Our findings reveal a novel mechanism for Tip60 mediated sleep–wake regulation via control of axonal growth and PDF levels within the sLNv-encompassing neural network and provide insight into epigenetic-based regulation of sleep disturbances observed in neurodegenerative diseases like Alzheimer’s disease. PMID:22982579
Transferring Codified Knowledge: Socio-Technical versus Top-Down Approaches
ERIC Educational Resources Information Center
Guzman, Gustavo; Trivelato, Luiz F.
2008-01-01
Purpose: This paper aims to analyse and evaluate the transfer process of codified knowledge (CK) performed under two different approaches: the "socio-technical" and the "top-down". It is argued that the socio-technical approach supports the transfer of CK better than the top-down approach. Design/methodology/approach: Case study methodology was…
Innovative Approaches to Teaching Technical Communication
ERIC Educational Resources Information Center
Bridgeford, Tracy, Ed.; Kitalong, Karla Saari, Ed.; Selfe, Dickie, Ed.
2004-01-01
"Innovative Approaches to Teaching Technical Communication" offers a variety of activities, projects, and approaches to energize pedagogy in technical communication and to provide a constructive critique of current practice. A practical collection, the approaches recommended here are readily adaptable to a range of technological and institutional…
Demir, Uygar Levent
2018-05-01
Underrotation of the nasal tip with narrow nasolabial angle is a common nasal deformity that leads to a long nose appearance, named drooping nose. In these patients, there are various techniques described to correct droopy tip and to achieve a desirable nasal tip rotation such as lateral crural steal, lateral crural overlay, tongue-ingroove, columellar strut graft, tip rotation sutures, cephalic trimming, and others. In this study, the effects of tongue-in-groove (TIG) and columellar strut graft (CS) and the contribution of cap graft on nasal tip rotation and projection were evaluated. Twenty-eight consecutive patients who underwent open approach rhinoplasty by the same senior author (ULD) between January 2015 and December 2016 with the diagnosis of septonasal deformity and droopy nasal tip were included. In 9 of these patients nasal tip was constructed with strut graft, in 6 patients with both strut and cap grafts, in 6 patients with TIG technique and in 7 patients with both TIG and cap graft. Standardized right lateral images were taken preoperatively and 6 months postoperatively to use for further assessments. The nasal tip rotation was evaluated by measuring nasolabial angle (NLA) and the nasal projection (NP) was evaluated by using the Goode method. Finally, the postoperative values of NLA and NP at the 6th month were compared with preoperative recorded values in between groups. Each group showed increase at nasal projection; however, significance was present only in CS graft and TIG groups (P=0.011 and P=0.027 relatively). Each 4 groups showed significant increase in nasal tip rotation. In addition, the comparison of percent changes between preoperative and postoperative NP and NLA revealed no difference (P=0.56 and P=0.431 relatively). In conclusion, the authors argued that TIG and CS graft techniques are both reliable methods to correct droopy nasal tip and using additional cap graft over dome area when required is safe and useful.
Management of acute variceal bleeding.
Herrera, Jorge L
2014-05-01
Acute variceal bleeding (AVB) is the most common cause of upper gastrointestinal hemorrhage in patients with cirrhosis. Advances in the management of AVB have resulted in decreased mortality. To minimize mortality, a multidisciplinary approach addressing airway safety, prompt judicious volume resuscitation, vasoactive and antimicrobial pharmacotherapy, and early endoscopy to obliterate varices is necessary. Placement of a transjugular intrahepatic portosystemic shunt (TIPS) has been used as rescue therapy for patients failing initial attempts at hemostasis. Patients who have a high likelihood of failing initial attempts at hemostasis may benefit from a more aggressive approach using TIPS earlier in their management. Copyright © 2014 Elsevier Inc. All rights reserved.
Frequency Response Studies using Receptance Coupling Approach in High Speed Spindles
NASA Astrophysics Data System (ADS)
Shaik, Jakeer Hussain; Ramakotaiah, K.; Srinivas, J.
2018-01-01
In order to assess the stability of high speed machining, estimate the frequency response at the end of tool tip is of great importance. Evaluating dynamic response of several combinations of integrated spindle-tool holder-tool will consume a lot of time. This paper presents coupled field dynamic response at tool tip for the entire integrated spindle tool unit. The spindle unit is assumed to be relying over the front and rear bearings and investigated using the Timoshenko beam theory to arrive the receptances at different locations of the spindle-tool unit. The responses are further validated with conventional finite element model as well as with the experiments. This approach permits quick outputs without losing accuracy of solution and further these methods are utilized to analyze the various design variables on system dynamics. The results obtained through this analysis are needed to design the better spindle unit in an attempt to reduce the frequency amplitudes at the tool tip to improvise the milling stability during cutting process.
Aperiodicity Correction for Rotor Tip Vortex Measurements
NASA Technical Reports Server (NTRS)
Ramasamy, Manikandan; Paetzel, Ryan; Bhagwat, Mahendra J.
2011-01-01
The initial roll-up of a tip vortex trailing from a model-scale, hovering rotor was measured using particle image velocimetry. The unique feature of the measurements was that a microscope was attached to the camera to allow much higher spatial resolution than hitherto possible. This also posed some unique challenges. In particular, the existing methodologies to correct for aperiodicity in the tip vortex locations could not be easily extended to the present measurements. The difficulty stemmed from the inability to accurately determine the vortex center, which is a prerequisite for the correction procedure. A new method is proposed for determining the vortex center, as well as the vortex core properties, using a least-squares fit approach. This approach has the obvious advantage that the properties are derived from not just a few points near the vortex core, but from a much larger area of flow measurements. Results clearly demonstrate the advantage in the form of reduced variation in the estimated core properties, and also the self-consistent results obtained using three different aperiodicity correction methods.
NASA Astrophysics Data System (ADS)
He, Zhengran
A newly-developed p-type organic semiconductor 6,13-bis (triisopropylsilylethynyl) pentacene (TIPS pentacene) demonstrates various advantages such as high mobility, air stability and solution processibility, but at the same time its application is restricted by major issues, such as crystal misorientation and performance variation of organic thin-film transistors (OTFTs). This dissertation demonstrates several different approaches to address these issues. As a result, both crystal orientation and areal coverage can be effectively improved, leading to an enhancement of average mobility and performance consistency of OTFTs. Chapter 1 presents an introduction and background of this dissertation. Chapter 2 explores the usage of inorganic silica nanoparticles to manipulate the morphology of TIPS pentacene thin films and the performance of solution-processed organic OTFTs. The resultant drop-cast films yield improved morphological uniformity at ~10% SiO2 loading, which also leads to a 3-fold increase in average mobility and nearly 4-times reduction in the ratio of standard deviation of mobility (μStdev) to average mobility (μAvg). The experimental results suggest that the SiO2 nanoparticles mostly aggregate at TIPS pentacene grain boundaries, and that 10% nanoparticle concentration effectively reduces the undesirable crystal misorientation without considerably compromising TIPS pentacene crystallinity. Chapter 3 discusses the utilization of air flow to effectively reduce the TIPS pentacene crystal anisotropy and enhance performance consistency in OTFTs. Under air-flow navigation (AFN), TIPS pentacene forms thin films with improved crystal orientation and increased areal coverage, which subsequently lead to a four-fold increase of average hole mobility and one order of magnitude enhancement in performance consistency. Chapter 4 investigates the critical roles of lateral and vertical phase separation in the performance of the next-generation organic and hybrid electronic devices. A novel method is demonstrated here to switch between lateral and vertical phase separation in semiconducting TIPS pentacene/ polymer blend films by simply varying the alkyl length of the polyacrylate polymer component. The phase separation modes depend on intermolecular interactions between small molecule TIPS pentacene and polymer additives. The blend film with a dominant vertical phase separation exhibits a significant enhancement in average mobility and performance consistency of organic OTFTs. Chapter 5 demonstrates an effective approach to improve both charge transport and performance consistency in solution-processed OTFTs by blending TIPS pentacene with a series of small-molecule additives: 4-butylbenzoic acid (BBA), 4-hexylbenzoic acid (HBA), and 4-octylbenzoic acid (OBA). These three small molecules share a benzoic acid moiety, but have different length of hydrophobic tails. The self-assembled interfacial layer of small molecules on the gate oxide surface leads to uniform deposition of TIPS pentacene crystal seeds and facilitates TIPS pentacene to grow along the tilted orientation of substrate, which results in a film of enhanced crystal orientation and areal coverage. OTFTs based on TIPS pentacene/small molecule blends demonstrate greatly improved average hole mobility and performance consistency, which correlates with the length of hydrophobic tail of the small-molecule additives. Chapter 6 summarizes the conclusions of this dissertation and the related future work.
Josty, I C; Ramaswamy, R; Laing, J H
2001-06-01
A case of a degloving injury to the foot is presented in a patient who also sustained severe contralateral lower-limb trauma. We report a technique for salvaging the foot by replacing the degloved skin as a full-thickness graft and securing it using the vacuum-assisted closure (VAC) device. A good outcome was achieved and technical tips are provided to facilitate reproduction of the procedure. Copyright 2001 The British Association of Plastic Surgeons.
Collaborative writing: Tools and tips.
Eapen, Bell Raj
2007-01-01
Majority of technical writing is done by groups of experts and various web based applications have made this collaboration easy. Email exchange of word processor documents with tracked changes used to be the standard technique for collaborative writing. However web based tools like Google docs and Spreadsheets have made the process fast and efficient. Various versioning tools and synchronous editors are available for those who need additional functionality. Having a group leader who decides the scheduling, communication and conflict resolving protocols is important for successful collaboration.
Users Guide for Smooth-Prop: A Program for Smoothing Propeller Tip Geometry
2013-10-01
Research and Development Canada – Atlantic Technical Memorandum DRDC Atlantic TM 2013-179 October 2013 c© Her Majesty the Queen in Right of Canada...a window You can magnify any region of the Blade or Plane Intersection windows by clicking and dragging with the left mouse button. A red rectangle...display. Each slider is a long rectangle containing a smaller black box: see Fig. 9. The black box is a handle that can be dragged back and forth
The AGARD tip research agenda for Scientific and Technical Information (STI)
NASA Technical Reports Server (NTRS)
Blados, Walter R.
1992-01-01
The Research Agenda contains three themes: information management, provision of information, and access to information. Provision of information is further divided into two subordinate themes, dissemination and bibliographic control; access to information is also further divided into two subordinate themes, barriers and equity and networking. Each theme or sub-theme was examined from four possible aspects, namely, human resources, quality assurance, cost, and technology. It was concluded that, in fact, a theme or sub-theme need not contain all four aspects.
The virtual isocentric aiming device: a new mechanical targeting concept.
Mendel, Thomas; Hänni, Markus; Gueorguiev, Boyko; Wohlrab, David; Hofmann, Gunther Olaf
2011-12-01
Minimally invasive fracture fixation can be technically demanding, especially in body regions characterised by complex bone anatomy and the presence of a significant amount of soft tissue. Hence, this procedure is associated with a high risk of implant malposition. As a consequence, radiation exposure to the patient and the surgeon increases within surgery. The purpose of this study was to evaluate the practicability and accuracy of a newly designed virtual isocentric aiming device (VIAD) as compared to the more traditional approach of the freehand insertion of K-wires. Forty polyurethane foam blocks were prepared with a reference wire (W ( R )) and covered by sponge material to simulate soft tissue. For the sake of comparison, both an untrained and an experienced surgeon were selected for the study and were advised to insert a K-wire into the foam block so as to have the same axis as the W ( R ) using both of the aforementioned methods. The clinical parameters of both techniques were analysed. In addition, 3-D precision data computed using CT-scans of each sample were evaluated. Device adjustment prolonged the time required for the experienced surgeon to complete the VIAD procedure when compared to the freehand method. However, using the VIAD, the number of plane changes made to the image intensifier in addition to the number of drill trials was significantly reduced by each surgeon. Furthermore, mechanical K-wire navigation leads to a decrease in the radiation exposure time for the untrained surgeon. VIAD-guided K-wires revealed a significant lower angle of deviation in relation to W ( R ). Tip-to-tip and tip-to-axis distances displayed a trend indicating reduced displacement values as well. The VIAD allows for simple wire insertion with increased precision as well as a reduction in radiation exposure, plane changes of the image intensifier and the number of drill trials compared to the freehand method. The VIAD also satisfies the demand for a less invasive technique. Prospectively, the VIAD represents a useful and cost-effective alternative to the freehand method.
Gap-mode enhancement on MoS2 probed by functionalized tip-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Alajlan, Abdulrahman M.; Voronine, Dmitri V.; Sinyukov, Alexander M.; Zhang, Zhenrong; Sokolov, Alexei V.; Scully, Marlan O.
2016-09-01
Surface enhancement of molecular spectroscopic signals has been widely used for sensing and nanoscale imaging. Because of the weak electromagnetic enhancement of Raman signals on semiconductors, it is motivating but challenging to study the electromagnetic effect separately from the chemical effects. We report tip-enhanced Raman scattering measurements on Au and bulk MoS2 substrates using a metallic tip functionalized with copper phthalocyanine molecules and demonstrate similar gap-mode enhancement on both substrates. We compare the experimental results with theoretical calculations to confirm the gap-mode enhancement on MoS2 using a well-established electrostatic model. The functionalized tip approach allows for suppressing the background and is ideal for separating electromagnetic and chemical enhancement mechanisms on various substrates. Our results may find a wide range of applications in MoS2-based devices, sensors, and metal-free nanoscale bio-imaging.
Rolland, N; Larson, D J; Geiser, B P; Duguay, S; Vurpillot, F; Blavette, D
2015-12-01
An analytical model describing the field evaporation dynamics of a tip made of a thin layer deposited on a substrate is presented in this paper. The difference in evaporation field between the materials is taken into account in this approach in which the tip shape is modeled at a mesoscopic scale. It was found that the non-existence of sharp edge on the surface is a sufficient condition to derive the morphological evolution during successive evaporation of the layers. This modeling gives an instantaneous and smooth analytical representation of the surface that shows good agreement with finite difference simulations results, and a specific regime of evaporation was highlighted when the substrate is a low evaporation field phase. In addition, the model makes it possible to calculate theoretically the tip analyzed volume, potentially opening up new horizons for atom probe tomographic reconstruction. Copyright © 2015 Elsevier B.V. All rights reserved.
A compact CCD-monitored atomic force microscope with optical vision and improved performances.
Mingyue, Liu; Haijun, Zhang; Dongxian, Zhang
2013-09-01
A novel CCD-monitored atomic force microscope (AFM) with optical vision and improved performances has been developed. Compact optical paths are specifically devised for both tip-sample microscopic monitoring and cantilever's deflection detecting with minimized volume and optimal light-amplifying ratio. The ingeniously designed AFM probe with such optical paths enables quick and safe tip-sample approaching, convenient and effective tip-sample positioning, and high quality image scanning. An image stitching method is also developed to build a wider-range AFM image under monitoring. Experiments show that this AFM system can offer real-time optical vision for tip-sample monitoring with wide visual field and/or high lateral optical resolution by simply switching the objective; meanwhile, it has the elegant performances of nanometer resolution, high stability, and high scan speed. Furthermore, it is capable of conducting wider-range image measurement while keeping nanometer resolution. Copyright © 2013 Wiley Periodicals, Inc.
Ab initio simulations of subatomic resolution images in noncontact atomic force microscopy
NASA Astrophysics Data System (ADS)
Kim, Minjung; Chelikowsky, James R.
2015-03-01
Direct imaging of polycyclic aromatic molecules with a subatomic resolution has recently been achieved with noncontact atomic force microscopy (nc-AFM). Specifically, nc-AFM employing a CO functionalized tip has provided details of the chemical bond in aromatic molecules, including the discrimination of bond order. However, the underlying physics of such high resolution imaging remains problematic. By employing new, efficient algorithms based on real space pseudopotentials, we calculate the forces between the nc-AFM tip and specimen. We simulate images of planar organic molecules with two different approaches: 1) with a chemically inert tip and 2) with a CO functionalized tip. We find dramatic differences in the resulting images, which are consistent with recent experimental work. Our work is supported by the DOE under DOE/DE-FG02-06ER46286 and by the Welch Foundation under Grant F-1837. Computational resources were provided by NERSC and XSEDE.
NASA Astrophysics Data System (ADS)
Erler, Engin
Tip clearance flow is the flow through the clearance between the rotor blade tip and the shroud of a turbomachine, such as compressors and turbines. This flow is driven by the pressure difference across the blade (aerodynamic loading) in the tip region and is a major source of loss in performance and aerodynamic stability in axial compressors of modern aircraft engines. An increase in tip clearance, either temporary due to differential radial expansion between the blade and the shroud during transient operation or permanent due to engine wear or manufacturing tolerances on small blades, increases tip clearance flow and results in higher fuel consumption and higher risk of engine surge. A compressor design that can reduce the sensitivity of its performance and aerodynamic stability to tip clearance increase would have a major impact on short and long-term engine performance and operating envelope. While much research has been carried out on improving nominal compressor performance, little had been done on desensitization to tip clearance increase beyond isolated observations that certain blade designs such as forward chordwise sweep, seem to be less sensitive to tip clearance size increase. The current project aims to identify through a computational study the flow features and associated mechanisms that reduces sensitivity of axial compressor rotors to tip clearance size and propose blade design strategies that can exploit these results. The methodology starts with the design of a reference conventional axial compressor rotor followed by a parametric study with variations of this reference design through modification of the camber line and of the stacking line of blade profiles along the span. It is noted that a simple desensitization method would be to reduce the aerodynamic loading of the blade tip which would reduce the tip clearance flow and its proportional contribution to performance loss. However, with the larger part of the work on the flow done in this region, this approach would entail a nominal performance penalty. Therefore, the chosen rotor design philosophy aims to keep the spanwise loading constant to avoid trading performance for desensitization. The rotor designs that resulted from this exercise are simulated in ANSYS CFX at different tip clearance sizes. The change in their performance with respect to tip clearance size (sensitivity) is compared both on an integral level in terms of pressure ratio and adiabatic efficiency, as well as on a detailed level in terms of aerodynamic losses and blockage associated with tip clearance flow. The sensitivity of aerodynamic stability is evaluated either directly through the simulations of the rotor characteristics up to the stall point (expensive in time and resources) for a few designs or indirectly through the position of the interface between the incoming and tip clearance flow with respect to the rotor leading edge plane. The latter approach is based on a generally observed stall criteria in modern axial compressors. The rotor designs are then assessed according to their sensitivity in comparison to that of the reference rotor design to detect features that can explain the trend in sensitivity to tip clearance size. These features can then be validated and the associated flow mechanisms explained through numerical simulations and modelling. Analysis of the database from the rotor parametric study shows that the observed trend in sensitivity cannot be explained by the shifting of the aerodynamic loading along the blade chord, as initially hypothesized based on the literature review. Instead, two flow features are found to reduce sensitivity of performance and stability to tip clearance, namely an increase in incoming meridional momentum in the tip region and a reduction/elimination of double leakage flow. Double leakage flow is the flow that exits the tip clearance of one blade and proceeds into the clearance of the adjacent blade rather than convecting downstream out of the local blade passage. These flow features are isolated and validated based on the reference rotor design through changes in the inlet total pressure condition to alter incoming flow momentum and blade number count to change double leakage rate. In terms of flow mechanism, double leakage is shown to be detrimental to performance and stability, and its proportional increase with tip clearance size explains the sensitivity increase in the presence of double leakage and, conversely, the desensitization effect of reducing or eliminating double leakage. The increase in incoming meridional momentum in the tip region reduces sensitivity to tip clearance through its reduction of double leakage as well as through improved mixing with tip clearance flow, as demonstrated by an analytical model without double leakage flow. The above results imply that any blade design strategy that exploits the two desensitizing flow features would reduce the performance and stability sensitivity to tip clearance size. The increase of the incoming meridional momentum can be achieved through forward chordwise sweep of the blade. The reduction of double leakage without changing blade pitch can be obtained by decreasing the blade stagger angle in the tip region. Examples of blade designs associated with these strategies are shown through CFX simulations to be successful in reducing sensitivity to tip clearance size.
Ordering theories: Typologies and conceptual frameworks for sociotechnical change.
Sovacool, Benjamin K; Hess, David J
2017-10-01
What theories or concepts are most useful at explaining socio technical change? How can - or cannot - these be integrated? To provide an answer, this study presents the results from 35 semi-structured research interviews with social science experts who also shared more than two hundred articles, reports and books on the topic of the acceptance, adoption, use, or diffusion of technology. This material led to the identification of 96 theories and conceptual approaches spanning 22 identified disciplines. The article begins by explaining its research terms and methods before honing in on a combination of fourteen theories deemed most relevant and useful by the material. These are: Sociotechnical Transitions, Social Practice Theory, Discourse Theory, Domestication Theory, Large Technical Systems, Social Construction of Technology, Sociotechnical Imaginaries, Actor-Network Theory, Social Justice Theory, Sociology of Expectations, Sustainable Development, Values Beliefs Norms Theory, Lifestyle Theory, and the Unified Theory of Acceptance and Use of Technology. It then positions these theories in terms of two distinct typologies. Theories can be placed into five general categories of being centered on agency, structure, meaning, relations or norms. They can also be classified based on their assumptions and goals rooted in functionalism, interpretivism, humanism or conflict. The article lays out tips for research methodology before concluding with insights about technology itself, analytical processes associated with technology, and the framing and communication of results. An interdisciplinary theoretical and conceptual inventory has much to offer students, analysts and scholars wanting to study technological change and society.
Ordering theories: Typologies and conceptual frameworks for sociotechnical change
Sovacool, Benjamin K; Hess, David J
2017-01-01
What theories or concepts are most useful at explaining socio technical change? How can – or cannot – these be integrated? To provide an answer, this study presents the results from 35 semi-structured research interviews with social science experts who also shared more than two hundred articles, reports and books on the topic of the acceptance, adoption, use, or diffusion of technology. This material led to the identification of 96 theories and conceptual approaches spanning 22 identified disciplines. The article begins by explaining its research terms and methods before honing in on a combination of fourteen theories deemed most relevant and useful by the material. These are: Sociotechnical Transitions, Social Practice Theory, Discourse Theory, Domestication Theory, Large Technical Systems, Social Construction of Technology, Sociotechnical Imaginaries, Actor-Network Theory, Social Justice Theory, Sociology of Expectations, Sustainable Development, Values Beliefs Norms Theory, Lifestyle Theory, and the Unified Theory of Acceptance and Use of Technology. It then positions these theories in terms of two distinct typologies. Theories can be placed into five general categories of being centered on agency, structure, meaning, relations or norms. They can also be classified based on their assumptions and goals rooted in functionalism, interpretivism, humanism or conflict. The article lays out tips for research methodology before concluding with insights about technology itself, analytical processes associated with technology, and the framing and communication of results. An interdisciplinary theoretical and conceptual inventory has much to offer students, analysts and scholars wanting to study technological change and society. PMID:28641502
Laser heating of scanning probe tips for thermal near-field spectroscopy and imaging
NASA Astrophysics Data System (ADS)
O'Callahan, Brian T.; Raschke, Markus B.
2017-02-01
Spectroscopy and microscopy of the thermal near-field yield valuable insight into the mechanisms of resonant near-field heat transfer and Casimir and Casimir-Polder forces, as well as providing nanoscale spatial resolution for infrared vibrational spectroscopy. A heated scanning probe tip brought close to a sample surface can excite and probe the thermal near-field. Typically, tip temperature control is provided by resistive heating of the tip cantilever. However, this requires specialized tips with limited temperature range and temporal response. By focusing laser radiation onto AFM cantilevers, we achieve heating up to ˜1800 K, with millisecond thermal response time. We demonstrate application to thermal infrared near-field spectroscopy (TINS) by acquiring near-field spectra of the vibrational resonances of silicon carbide, hexagonal boron nitride, and polytetrafluoroethylene. We discuss the thermal response as a function of the incident excitation laser power and model the dominant cooling contributions. Our results provide a basis for laser heating as a viable approach for TINS, nanoscale thermal transport measurements, and thermal desorption nano-spectroscopy.
Tip60 HAT Action Mediates Environmental Enrichment Induced Cognitive Restoration
Xu, Songjun; Panikker, Priyalakshmi; Iqbal, Sahira; Elefant, Felice
2016-01-01
Environmental enrichment (EE) conditions have beneficial effects for reinstating cognitive ability in neuropathological disorders like Alzheimer’s disease (AD). While EE benefits involve epigenetic gene control mechanisms that comprise histone acetylation, the histone acetyltransferases (HATs) involved remain largely unknown. Here, we examine a role for Tip60 HAT action in mediating activity- dependent beneficial neuroadaptations to EE using the Drosophila CNS mushroom body (MB) as a well-characterized cognition model. We show that flies raised under EE conditions display enhanced MB axonal outgrowth, synaptic marker protein production, histone acetylation induction and transcriptional activation of cognition linked genes when compared to their genotypically identical siblings raised under isolated conditions. Further, these beneficial changes are impaired in both Tip60 HAT mutant flies and APP neurodegenerative flies. While EE conditions provide some beneficial neuroadaptive changes in the APP neurodegenerative fly MB, such positive changes are significantly enhanced by increasing MB Tip60 HAT levels. Our results implicate Tip60 as a critical mediator of EE-induced benefits, and provide broad insights into synergistic behavioral and epigenetic based therapeutic approaches for treatment of cognitive disorder. PMID:27454757
Tip60 HAT Action Mediates Environmental Enrichment Induced Cognitive Restoration.
Xu, Songjun; Panikker, Priyalakshmi; Iqbal, Sahira; Elefant, Felice
2016-01-01
Environmental enrichment (EE) conditions have beneficial effects for reinstating cognitive ability in neuropathological disorders like Alzheimer's disease (AD). While EE benefits involve epigenetic gene control mechanisms that comprise histone acetylation, the histone acetyltransferases (HATs) involved remain largely unknown. Here, we examine a role for Tip60 HAT action in mediating activity- dependent beneficial neuroadaptations to EE using the Drosophila CNS mushroom body (MB) as a well-characterized cognition model. We show that flies raised under EE conditions display enhanced MB axonal outgrowth, synaptic marker protein production, histone acetylation induction and transcriptional activation of cognition linked genes when compared to their genotypically identical siblings raised under isolated conditions. Further, these beneficial changes are impaired in both Tip60 HAT mutant flies and APP neurodegenerative flies. While EE conditions provide some beneficial neuroadaptive changes in the APP neurodegenerative fly MB, such positive changes are significantly enhanced by increasing MB Tip60 HAT levels. Our results implicate Tip60 as a critical mediator of EE-induced benefits, and provide broad insights into synergistic behavioral and epigenetic based therapeutic approaches for treatment of cognitive disorder.
Critical dynamics in population vaccinating behavior.
Pananos, A Demetri; Bury, Thomas M; Wang, Clara; Schonfeld, Justin; Mohanty, Sharada P; Nyhan, Brendan; Salathé, Marcel; Bauch, Chris T
2017-12-26
Vaccine refusal can lead to renewed outbreaks of previously eliminated diseases and even delay global eradication. Vaccinating decisions exemplify a complex, coupled system where vaccinating behavior and disease dynamics influence one another. Such systems often exhibit critical phenomena-special dynamics close to a tipping point leading to a new dynamical regime. For instance, critical slowing down (declining rate of recovery from small perturbations) may emerge as a tipping point is approached. Here, we collected and geocoded tweets about measles-mumps-rubella vaccine and classified their sentiment using machine-learning algorithms. We also extracted data on measles-related Google searches. We find critical slowing down in the data at the level of California and the United States in the years before and after the 2014-2015 Disneyland, California measles outbreak. Critical slowing down starts growing appreciably several years before the Disneyland outbreak as vaccine uptake declines and the population approaches the tipping point. However, due to the adaptive nature of coupled behavior-disease systems, the population responds to the outbreak by moving away from the tipping point, causing "critical speeding up" whereby resilience to perturbations increases. A mathematical model of measles transmission and vaccine sentiment predicts the same qualitative patterns in the neighborhood of a tipping point to greatly reduced vaccine uptake and large epidemics. These results support the hypothesis that population vaccinating behavior near the disease elimination threshold is a critical phenomenon. Developing new analytical tools to detect these patterns in digital social data might help us identify populations at heightened risk of widespread vaccine refusal. Copyright © 2017 the Author(s). Published by PNAS.
Critical dynamics in population vaccinating behavior
Pananos, A. Demetri; Bury, Thomas M.; Wang, Clara; Schonfeld, Justin; Mohanty, Sharada P.; Nyhan, Brendan; Bauch, Chris T.
2017-01-01
Vaccine refusal can lead to renewed outbreaks of previously eliminated diseases and even delay global eradication. Vaccinating decisions exemplify a complex, coupled system where vaccinating behavior and disease dynamics influence one another. Such systems often exhibit critical phenomena—special dynamics close to a tipping point leading to a new dynamical regime. For instance, critical slowing down (declining rate of recovery from small perturbations) may emerge as a tipping point is approached. Here, we collected and geocoded tweets about measles–mumps–rubella vaccine and classified their sentiment using machine-learning algorithms. We also extracted data on measles-related Google searches. We find critical slowing down in the data at the level of California and the United States in the years before and after the 2014–2015 Disneyland, California measles outbreak. Critical slowing down starts growing appreciably several years before the Disneyland outbreak as vaccine uptake declines and the population approaches the tipping point. However, due to the adaptive nature of coupled behavior–disease systems, the population responds to the outbreak by moving away from the tipping point, causing “critical speeding up” whereby resilience to perturbations increases. A mathematical model of measles transmission and vaccine sentiment predicts the same qualitative patterns in the neighborhood of a tipping point to greatly reduced vaccine uptake and large epidemics. These results support the hypothesis that population vaccinating behavior near the disease elimination threshold is a critical phenomenon. Developing new analytical tools to detect these patterns in digital social data might help us identify populations at heightened risk of widespread vaccine refusal. PMID:29229821
A Reduced Model for Prediction of Thermal and Rotational Effects on Turbine Tip Clearance
NASA Technical Reports Server (NTRS)
Kypuros, Javier A.; Melcher, Kevin J.
2003-01-01
This paper describes a dynamic model that was developed to predict changes in turbine tip clearance the radial distance between the end of a turbine blade and the abradable tip seal. The clearance is estimated by using a first principles approach to model the thermal and mechanical effects of engine operating conditions on the turbine sub-components. These effects are summed to determine the resulting clearance. The model is demonstrated via a ground idle to maximum power transient and a lapse-rate takeoff transient. Results show the model demonstrates the expected pinch point behavior. The paper concludes by identifying knowledge gaps and suggesting additional research to improve the model.
Smith, Selina A; Sheats, Joyce Q; Whitehead, Mary S; Delmoor, Ernestine; Britt, Thomas; Harris, Cassandra L; Robinson-Flint, Janette; Porche-Smith, L Monique; Umeakunne, Kayellen Edmonds; Coughlin, Steven S
Supplementing nutrition education with skills-building activities may enhance community awareness of diet-related cancer prevention guidelines. To develop a cookbook with lifestyle tips, recipes were solicited from the National Black Leadership Initiative on Cancer (NBLIC) community coalitions and dietary intake advice from participants in the Educational Program to Increase Colorectal Cancer Screening (EPICS). With guidance from a chef and registered dietitian, recipes were tested, assessed, and transformed; lifestyle advice was obtained from focus groups. The cookbook with lifestyle tips, named "Down Home Healthy Living (DHHL) 2.0," was distributed in print form to 2,500 EPICS participants and shared electronically through websites and social media.
Smith, Selina A.; Sheats, Joyce Q.; Whitehead, Mary S.; Delmoor, Ernestine; Britt, Thomas; Harris, Cassandra L.; Robinson-Flint, Janette; Porche-Smith, L. Monique; Umeakunne, Kayellen Edmonds; Coughlin, Steven S.
2015-01-01
Supplementing nutrition education with skills-building activities may enhance community awareness of diet-related cancer prevention guidelines. To develop a cookbook with lifestyle tips, recipes were solicited from the National Black Leadership Initiative on Cancer (NBLIC) community coalitions and dietary intake advice from participants in the Educational Program to Increase Colorectal Cancer Screening (EPICS). With guidance from a chef and registered dietitian, recipes were tested, assessed, and transformed; lifestyle advice was obtained from focus groups. The cookbook with lifestyle tips, named “Down Home Healthy Living (DHHL) 2.0,” was distributed in print form to 2,500 EPICS participants and shared electronically through websites and social media. PMID:26709388
NASA Astrophysics Data System (ADS)
McCaffrey, M. S.; Stroeve, J. C.
2011-12-01
The "Grand Challenges" to address Global Change identified by the International Council for Science (ICSU) and its partners through the Earth System Sustainability Initiative-improving forecasting, enhancing and integrating observation systems, confining and minimizing global environmental change, responding effectively to change, as well as innovating and evaluating these efforts-require an integrative approach that engages and inspires society in general and young people in particular. What are some of the effective strategies-and stumbling blocks-in being able to make Earth System science and related sustainability efforts relevant and practical to non-technical audiences? Recent climate education projects have pioneered new strategies toward linking and infusing research with education, science with solutions. For example, the Climate Literacy and Energy Awareness Network (CLEAN), a National Science Digital Library Pathway funded by NSF, has approached this integral approach by "closing the loop" between climate and energy topics, identifying and annotating high quality online resources relating to the carbon cycle and related topics. The Inspiring Climate Education Excellence (ICEE) project, funded by NASA, offers professional development for teachers that infuses climate science with solutions as an emerging "best practice" while being sensitive to the emotional, psychological and political aspects of avoiding "gloom and doom" on one hand or advocating for particular policy solutions on another. Other examples includes NASA's climate website (http://climate.nasa.gov ), which serves as a robust, engaging portal for climate research and data, especially for educators. The recent PBS series Earth: The Operators' Manual and related book and website are other recent example of how climate science research, education and solutions can be incorporated in a way that is appealing and informative. The Alliance for Climate Education (ACE) has given assemblies in thousands of US high schools that integrate climate science and solutions in a way that inspires and informs youth, and similar programs exist internationally. Other approaches to prepare vulnerable communities, especially young people, for natural hazards and human-induced environmental change include programs such as Plan International's "Child Centered Disaster Risk Reduction- Building Resilience Through Participation," and their "Weathering the Storm" project, focusing on integrating the needs of teenage girls with climate change adaptation and risk reduction. While minimizing global environmental and climate change is crucial, these and related programs that weave research with education, science with solutions offer the potential for addressing the "Grand Challenges" by better preparing for societal and environmental tipping points through a more balanced and integrated approach to addressing change."
Rotorcraft In-Plane Noise Reduction Using Active/Passive Approaches with Induced Vibration Tracking
NASA Astrophysics Data System (ADS)
Chia, Miang Hwee
A comprehensive study of the use of active and passive approaches for in-plane noise reduction, including the vibrations induced during noise reduction, was conducted on a hingeless rotor configuration resembling the MBB BO-105 rotor. First, a parametric study was performed to examine the effects of rotor blade stiffness on the vibration and noise reduction performance of a 20%c plain trailing edge flap and a 1.5%c sliding microflap. This was accomplished using a comprehensive code AVINOR (for Active VIbration and NOise Reduction). A two-dimensional unsteady reduced order aerodynamic model (ROM), using the Rational Function Approximation approach and CFD-based oscillatory aerodynamic load data, was used in the comprehensive code. The study identified a hingeless blade configuration with torsional frequency of 3.17/rev as an optimum configuration for studying vibration and noise reduction using on-blade control devices such as flaps or microflaps. Subsequently, a new suite of computational tools capable of predicting in-plane low frequency sound pressure level (LFSPL) rotorcraft noise and its control was developed, replacing the acoustic module WOPWOP in AVINOR with a new acoustic module HELINOIR (for HELIcopter NOIse Reduction), which overcomes certain limitations associated with WOPWOP. The new suite, consisting of the AVINOR/HELINOIR combination, was used to study active flaps, as well as microflaps operating in closed-loop mode for in-plane noise reduction. An alternative passive in-plane noise reduction approach using modification to the blade tip in the 10%R outboard region was also studied. The new suite consisting of the AVINOR/HELINOIR combination based on a compact aeroacoustic model was validated by comparing with wind tunnel test results, and subsequently verified by comparing with computational results. For active control, the in-plane noise reduction obtained with a single 20%c plain trailing edge flap during level flight at a moderate advance ratio was examined. Different configurations of far-field and near-field feedback microphone locations were examined to develop a fundamental understanding of the feedback microphone locations on the noise reduction process A near-field microphone located on the tip of a nose boom was found to produce a LFSPL reduction of up to 6dB. However, this noise reduction was accompanied by an out-of-plane noise increase of 18dB and 60% increase in vertical hub shear. For passive control, three tip geometries having sweep, dihedral, and anhedral, were considered. The tip dihedral reduced LFSPL by up to 2dB without a vibratory load penalty. However, this was accompanied by an increase in the mid frequency sound pressure levels (MFSPL). The tip sweep and tip anhedral produced an increase in in-plane LFSPL below the horizon. A comparison of the active and passive approaches indicated that active approaches implemented by a plain flap with a feedback microphone located on the nose boom is superior to the passive control approaches. However, there is a general trade-off between LFSPL reduction, MFSPL generation and vibratory hub loads induced by noise control.
Tip localization of an atomic force microscope in transmission microscopy with nanoscale precision
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumann, Fabian; Pippig, Diana A., E-mail: diana.pippig@physik.uni-muenchen.de; Gaub, Hermann E.
Since the atomic force microscope (AFM) has evolved into a general purpose platform for mechanical experiments at the nanoscale, the need for a simple and generally applicable localization of the AFM cantilever in the reference frame of an optical microscope has grown. Molecular manipulations like in single molecule cut and paste or force spectroscopy as well as tip mediated nanolithography are prominent examples for the broad variety of applications implemented to date. In contrast to the different kinds of superresolution microscopy where fluorescence is used to localize the emitter, we, here, employ the absorbance of the tip to localize itsmore » position in transmission microscopy. We show that in a low aperture illumination, the tip causes a significant reduction of the intensity in the image plane of the microscope objective when it is closer than a few hundred nm. By independently varying the z-position of the sample slide, we could verify that this diffraction limited image of the tip is not caused by a near field effect but is rather caused by the absorbance of the transmitted light in the low apex needle-like tip. We localized the centroid position of this tip image with a precision of better than 6 nm and used it in a feedback loop to position the tip into nano-apertures of 110 nm radius. Single-molecule force spectroscopy traces on the unfolding of individual green fluorescent proteins within the nano-apertures showed that their center positions were repeatedly approached with very high fidelity leaving the specific handle chemistry on the tip’s surface unimpaired.« less
A Design Thinking Approach to Teaching Knowledge Management
ERIC Educational Resources Information Center
Wang, Shouhong; Wang, Hai
2008-01-01
Pedagogies for knowledge management courses are still undeveloped. This Teaching Tip introduces a design thinking approach to teaching knowledge management. An induction model used to guide students' real-life projects for knowledge management is presented. (Contains 1 figure.)
On mapping subangstrom electron clouds with force microscopy.
Wright, C Alan; Solares, Santiago D
2011-11-09
In 2004 Hembacher et al. (Science 2004, 305, 380-383) reported simultaneous higher-harmonics atomic force mocroscopy (AFM)/scanning tunneling microscopy (STM) images acquired while scanning a graphite surface with a tungsten tip. They interpreted the observed subatomic features in the AFM images as the signature of lobes of increased electron density at the tungsten tip apex. Although these intriguing images have stirred controversy, an in-depth theoretical feasibility study has not yet been produced. Here we report on the development of a method for simulating higher harmonics AFM images and its application to the same system. Our calculations suggest that four lobes of increased electron density are expected to be present at a W(001) tip apex atom and that the corresponding higher harmonics AFM images of graphite can exhibit 4-fold symmetry features. Despite these promising results, open questions remain since the calculated amplitudes of the higher harmonics generated by the short-range forces are on the order of hundredths of picometers, leading to very small corrugations in the theoretical images. Additionally, the complex, intermittent nature of the tip-sample interaction, which causes constant readjustment of the tip and sample orbitals as the tip approaches and retracts from the surface, prevents a direct quantitative connection between the electron density and the AFM image features.
Fusion of electromagnetic trackers to improve needle deflection estimation: simulation study.
Sadjadi, Hossein; Hashtrudi-Zaad, Keyvan; Fichtinger, Gabor
2013-10-01
We present a needle deflection estimation method to anticipate needle bending during insertion into deformable tissue. Using limited additional sensory information, our approach reduces the estimation error caused by uncertainties inherent in the conventional needle deflection estimation methods. We use Kalman filters to combine a kinematic needle deflection model with the position measurements of the base and the tip of the needle taken by electromagnetic (EM) trackers. One EM tracker is installed on the needle base and estimates the needle tip position indirectly using the kinematic needle deflection model. Another EM tracker is installed on the needle tip and estimates the needle tip position through direct, but noisy measurements. Kalman filters are then employed to fuse these two estimates in real time and provide a reliable estimate of the needle tip position, with reduced variance in the estimation error. We implemented this method to compensate for needle deflection during simulated needle insertions and performed sensitivity analysis for various conditions. At an insertion depth of 150 mm, we observed needle tip estimation error reductions in the range of 28% (from 1.8 to 1.3 mm) to 74% (from 4.8 to 1.2 mm), which demonstrates the effectiveness of our method, offering a clinically practical solution.
Ultrathin MoS2 and WS2 layers on silver nano-tips as electron emitters
NASA Astrophysics Data System (ADS)
Loh, Tamie A. J.; Tanemura, Masaki; Chua, Daniel H. C.
2016-09-01
2-dimensional (2D) inorganic analogues of graphene such as MoS2 and WS2 present interesting opportunities for field emission technology due to their high aspect ratio and good electrical conductivity. However, research on 2D MoS2 and WS2 as potential field emitters remains largely undeveloped compared to graphene. Herein, we present an approach to directly fabricate ultrathin MoS2 and WS2 onto Ag nano-tips using pulsed laser deposition at low temperatures of 450-500 °C. In addition to providing a layer of chemical and mechanical protection for the Ag nano-tips, the growth of ultrathin MoS2 and WS2 layers on Ag led to enhanced emission properties over that of pristine nano-tips due to a reduction of the effective barrier height arising from charge injection from Ag to the overlying MoS2 or WS2. For WS2 on Ag nano-tips, the phasic mixture was also an important factor influencing the field emission performance. The presence of 1T-WS2 at the metal-WS2 interface in a hybrid film of 2H/1T-WS2 leads to improvement in the field emission capabilities as compared to pure 2H-WS2 on Ag nano-tips.
Transillumination for needle localization in the larynx.
Hoffman, Henry T; Dailey, Seth H; Bock, Jonathan M; Thibeault, Susan L; McCulloch, Timothy M
2015-10-01
Transillumination through laryngeal soft tissue may be used to direct percutaneous transcricothyroid membrane subepithelial needle placement in the larynx. Cadaver simulation (canine and human). Lighted devices, including sialendoscopes and fiberoptic cables, were tested as transilluminating obturators in trocars and needles through multiple studies to identify appropriate illumination, monitoring, and equipment for successful localization of needle/trocar tips placed within laryngeal tissue. Lighted 250-micron fiberoptic cables within 23-gauge needles were successfully placed percutaneously through the cricothyroid membrane and maneuvered submucosally into Reinke's space, the midlateral vocal fold, and through the thyroarytenoid gap with monitoring via flexible transnasal laryngoscopy. Technical adaptations in the course of study permitted successful simulation of clinical use in full cadaver study for accurate injection laryngoplasty, confirmed by laryngeal dissection following collagen injection. Small caliber fiberoptic cables are useful as transilluminating obturators to accurately direct needle position within laryngeal tissue. Clinical application of this new technique is anticipated to improve the accuracy of percutaneous needle localization in the larynx, as well as to assist in directed instrumentation of the larynx from an external approach. N/A. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Tips and tricks for flow cytometry-based analysis and counting of microparticles.
Poncelet, Philippe; Robert, Stéphane; Bailly, Nicolas; Garnache-Ottou, Francine; Bouriche, Tarik; Devalet, Bérangère; Segatchian, Jerard H; Saas, Philippe; Mullier, François
2015-10-01
Submicron-sized extra-cellular vesicles generated by budding from the external cell membranes, microparticles (MPs) are important actors in transfusion as well as in other medical specialties. After briefly positioning their role in the characterization of labile blood products, this technically oriented chapter aims to review practical points that need to be considered when trying to use flow cytometry for the analysis, characterization and absolute counting of MP subsets. Subjects of active discussions relative to instrumentation will include the choice of the trigger parameter, possible standardization approaches requiring instrument quality-control, origin and control of non-specific background and of coincidence artifacts, choice of the type of electronic signals, optimal sheath fluid and sample speed. Questions related to reagents will cover target antigens and receptors, multi-color reagents, negative controls, enumeration of MPs and limiting artifacts due to unexpected (micro-) coagulation of plasma samples. Newly detected problems are generating innovative solutions and flow cytometry will continue to remain the technology of choice for the analysis of MPs, in the domain of transfusion as well as in many diverse specialties. Copyright © 2015 Elsevier Ltd. All rights reserved.
Pulverization provides a mechanism for the nucleation of earthquakes at low stress on strong faults
Felzer, Karen R.
2014-01-01
An earthquake occurs when rock that has been deformed under stress rebounds elastically along a fault plane (Gilbert, 1884; Reid, 1911), radiating seismic waves through the surrounding earth. Rupture along the entire fault surface does not spontaneously occur at the same time, however. Rather the rupture starts in one tiny area, the rupture nucleation zone, and spreads sequentially along the fault. Like a row of dominoes, one bit of rebounding fault triggers the next. This triggering is understood to occur because of the large dynamic stresses at the tip of an active seismic rupture. The importance of these crack tip stresses is a central question in earthquake physics. The crack tip stresses are minimally important, for example, in the time predictable earthquake model (Shimazaki and Nakata, 1980), which holds that prior to rupture stresses are comparable to fault strength in many locations on the future rupture plane, with bits of variation. The stress/strength ratio is highest at some point, which is where the earthquake nucleates. This model does not require any special conditions or processes at the nucleation site; the whole fault is essentially ready for rupture at the same time. The fault tip stresses ensure that the rupture occurs as a single rapid earthquake, but the fact that fault tip stresses are high is not particularly relevant since the stress at most points does not need to be raised by much. Under this model it should technically be possible to forecast earthquakes based on the stress-renewaql concept, or estimates of when the fault as a whole will reach the critical stress level, a practice used in official hazard mapping (Field, 2008). This model also indicates that physical precursors may be present and detectable, since stresses are unusually high over a significant area before a large earthquake.
Microspheres in Plasma Display Panels
NASA Technical Reports Server (NTRS)
2006-01-01
Filling small bubbles of molten glass with gases is just as difficult as it sounds, but the technical staff at NASA is not known to shy away from a difficult task. When Microsphere Systems, Inc. (MSI), of Ypsilanti, Michigan, and Imaging Systems Technology, Inc. (IST), of Toledo, Ohio, were trying to push the limits of plasma displays but were having difficulty with the designs, NASA s Glenn Garrett Morgan Commercialization Initiative (GMCI) assembled key personnel at Glenn Research Center and Ohio State University for a brainstorming session to come up with a solution for the companies. They needed a system that could produce hollow, glass micro-sized spheres (microspheres) that could be filled with a variety of gasses. But the extremely high temperature required to force the micro-sized glass bubbles to form at the tip of a metal nozzle resulted in severe discoloration of the microspheres. After countless experiments on various glass-metal combinations, they had turned to the GMCI for help. NASA experts in advanced metals, ceramics, and glass concluded that a new design approach was necessary. The team determined that what was needed was a phosphate glass composition that would remain transparent, and they went to work on a solution. Six weeks later, using the design tips from the NASA team, Tim Henderson, president of MSI, had designed a new system in which all surfaces in contact with the molten glass would be ceramic instead of metal. Meanwhile, IST was able to complete a Phase I Small Business Innovation Research (SBIR) grant supported by the National Science Foundation (NSF) and supply a potential customer with samples of the microspheres for evaluation as filler materials for high-performance insulations.
Thomas, Pious; Sekhar, Aparna Chandra
2017-05-01
The interior of plants constitutes a unique environment for microorganisms with various organisms inhabiting as endophytes. Unlike subterranean plant parts, aboveground parts are relatively less explored for endophytic microbial diversity. We employed a combination of cultivation and molecular approaches to study the endophytic bacterial diversity in banana shoot-tips. Cultivable bacteria from 20 sucker shoot-tips of cv. Grand Naine included 37 strains under 16 genera and three phyla (Proteobacteria, Actinobacteria, Firmicutes). 16S rRNA gene-ribotyping approach on 799f and 1492r PCR-amplicons to avoid plant organelle sequences was ineffective showing limited bacterial diversity. 16S rRNA metagene profiling targeting the V3-V4 hypervariable region after filtering out the chloroplast (74.2 %), mitochondrial (22.9 %), and unknown sequences (1.1 %) revealed enormous bacterial diversity. Proteobacteria formed the predominant phylum (64 %) succeeded by Firmicutes (12.1 %), Actinobacteria (9.5 %), Bacteroidetes (6.4 %), Planctomycetes, Cyanobacteria, and minor shares (<1 %) of 14 phyla including several candidate phyla besides the domain Euryarchaeota (0.2 %). Microbiome analysis of single shoot-tips through 16S rRNA V3 region profiling showed similar taxonomic richness and diversity and was less affected by plant sequence interferences. DNA extraction kit ominously influenced the phylogenetic diversity. The study has revealed vast diversity of normally uncultivable endophytic bacteria prevailing in banana shoot-tips (20 phyla, 46 classes) with about 2.6 % of the deciphered 269 genera and 1.5 % of the 656 observed species from the same source of shoot-tips attained through cultivation. The predominant genera included several agriculturally important bacteria. The study reveals an immense ecosystem of endophytic bacteria in banana shoot tissues endorsing the earlier documentation of intracellular "Cytobacts" and "Peribacts" with possible roles in plant holobiome and hologenome.
NASA Technical Reports Server (NTRS)
Pinelli, Thomas E.
1992-01-01
The goal is the creation of a generally accepted, systematically developed and implemented, but user focused, research agenda for the Advisory Group for Aerospace Research and Development (AGARD) and the Technical Information Panel (TIP) member countries. Information use seldom exists as an isolated incident. Information use usually takes place within organizational and interpersonal contexts. Therefore, it should not be studied in isolation, but rather in an holistic environment. Once implemented, this research agenda could be completed within 3 to 5 years. The results would be generalizable to AGARD member nations, would form the basis for the development of theory based practice, and would form a significant body of knowledge that can be used by AGARD information professionals for policy, practice, product, and systems development.
Final Technical Report for SISGR: Ultrafast Molecular Scale Chemical Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hersam, Mark C.; Guest, Jeffrey R.; Guisinger, Nathan P.
2017-04-10
The Northwestern-Argonne SISGR program utilized newly developed instrumentation and techniques including integrated ultra-high vacuum tip-enhanced Raman spectroscopy/scanning tunneling microscopy (UHV-TERS/STM) and surface-enhanced femtosecond stimulated Raman scattering (SE-FSRS) to advance the spatial and temporal resolution of chemical imaging for the study of photoinduced dynamics of molecules on plasmonically active surfaces. An accompanying theory program addressed modeling of charge transfer processes using constrained density functional theory (DFT) in addition to modeling of SE-FSRS, thereby providing a detailed description of the excited state dynamics. This interdisciplinary and highly collaborative research resulted in 62 publications with ~ 48% of them being co-authored by multiplemore » SISGR team members. A summary of the scientific accomplishments from this SISGR program is provided in this final technical report.« less
Image simulation and surface reconstruction of undercut features in atomic force microscopy
NASA Astrophysics Data System (ADS)
Qian, Xiaoping; Villarrubia, John; Tian, Fenglei; Dixson, Ronald
2007-03-01
CD-AFMs (critical dimension atomic force microscopes) are instruments with servo-control of the tip in more than one direction. With appropriately "boot-shaped" or flared tips, such instruments can image vertical or even undercut features. As with any AFM, the image is a dilation of the sample shape with the tip shape. Accurate extraction of the CD requires a correction for the tip effect. Analytical methods to correct images for the tip shape have been available for some time for the traditional (vertical feedback only) AFMs, but were until recently unavailable for instruments with multi-dimensional feedback. Dahlen et al. [J. Vac. Sci. Technol. B23, pp. 2297-2303, (2005)] recently introduced a swept-volume approach, implemented for 2-dimensional (2D) feedback. It permits image simulation and sample reconstruction, techniques previously developed for the traditional instruments, to be extended for the newer tools. We have introduced [X. Qian and J. S. Villarrubia, Ultramicroscopy, in press] an alternative dexel-based method, that does the same in either 2D or 3D. This paper describes the application of this method to sample shapes of interest in semiconductor manufacturing. When the tip shape is known (e.g., by prior measurement using a tip characterizer) a 3D sample surface may be reconstructed from its 3D image. Basing the CD measurement upon such a reconstruction is shown here to remove some measurement artifacts that are not removed (or are incompletely removed) by the existing measurement procedures.
Kovac, Jason R; Luke, Patrick P
2010-01-01
Excision of renal cell carcinoma (RCC) with corresponding vena cava thrombus is a technical challenge requiring open resection and vascular clamping. A 58 year old male with a right kidney tumor presented with a thrombus extending 1 cm into the vena cava. Using a hand-assisted transperitoneal approach through a 7 cm gel-port, the right kidney was dissected and the multiple vascular collaterals supplying the tumor were identified and isolated. The inferior vena cava was mobilized 4 cm cephalad and 4 cm caudal to the right renal vein. Lateral manual traction was applied to the right kidney allowing the tumor thrombus to be retracted into the renal vein, clear of the vena cava. After laparoscopic ultrasonographic confirmation of the location of the tip of the tumor thrombus, an articulating laparoscopic vascular stapler was used to staple the vena cava at the ostium of the right renal vein. This allowed removal of the tumor thrombus without the need for a Satinsky clamp. The surgery was completed in 243 minutes with no intra-operative complications. The entire kidney and tumor thrombus was removed with negative surgical margins. Estimated blood loss was 300 cc. We present a laparoscopic resection of a renal mass with associated level II thrombus using a hand-assisted approach. In patients with minimal caval involvement, our surgical approach presents an option to the traditional open resection of a renal mass.
Quartararo, N; Barry, P H
1987-12-01
A technical problem associated with the patch clamp technique has been the changing of solutions bathing the membrane patch. The simple technique described here solves this problem by means of a movable polythene sleeve placed on the shaft of the patch clamp pipette. The sleeve is initially placed so that the tip of the pipette is exposed. A gigaohm seal is formed using standard techniques. The patch is then excised and the sleeve is slipped down a few mm past the end of the tip of the pipette. When the pipette and sleeve is now removed from the solution, a small drop of solution covering the membrane patch is held in place at the end of the sleeve by surface tension. The pipette is then easily transferred to a different solution without passing the membrane patch through the air-water interface. The sleeve is then simply pulled back up the pipette shaft to expose the membrane patch to the new solution.
Piek, J; Raes, P
1996-01-01
We described a new ventricular catheter that is the combination of a "classic" ventricular catheter with a piezo-resistive transducer at its tip. The device allows parallel recordings of intraventricular fluid pressure via a chip and a fluid-filled external transducer, drainage of cerebrospinal fluid from the ventricle or injection of fluid into the ventricle with simultaneous monitoring of intracranial pressure, and recording of brain tissue pressure in cases of misplacement or dislocation of the ventricular catheter or in cases of progressively narrowing ventricles caused by brain edema. Clinical tests in various situations at different pressure ranges (total recording time, 1356 h in 13 patients) gave excellent correlations of both pressures. Application of the device is especially indicated in clinical situations in which pressure-controlled drainage is desirable, occlusion of ventricular bolts is likely, or pressure-volume tests are needed.
Completion of the Design of the Top End Optical Assembly for ATST
NASA Astrophysics Data System (ADS)
Canzian, Blaise; Barentine, J.
2013-01-01
L-3 Integrated Optical Systems (IOS) Division has been selected by the National Solar Observatory (NSO) to make the Top End Optical Assembly (TEOA) for the 4-meter Advanced Technology Solar Telescope (ATST) to operate at Haleakala, Maui. ATST will perform to a very high optical performance level in a difficult operational environment. The TEOA (including a 0.65-meter silicon carbide secondary mirror and support, mirror thermal management system, mirror positioning and fast tip-tilt system, field stop with thermally managed heat dump, Lyot stop, safety interlock and control system, and support frame) operates in the “hot spot” at the prime focus of the ATST, presenting unusual challenges. L-3 IOS has passed Critical Design Review of the TEOA. In this paper, we describe L-3 IOS success meeting technical challenges, including our solutions for optic fabrication, opto-mechanical positioning, rejected and stray light control, wavefront tip-tilt compensation, and thermal management and control.
Manuel, D G; Ho, T H; Harper, S; Anderson, G M; Lynch, J; Rosella, L C
2014-07-01
Most individual preventive therapies potentially narrow or widen health disparities depending on the difference in community effectiveness across socioeconomic position (SEP). The equity tipping point (defined as the point at which health disparities become larger) can be calculated by varying components of community effectiveness such as baseline risk of disease, intervention coverage and/or intervention efficacy across SEP. We used a simple modelling approach to estimate the community effectiveness of diabetes prevention across SEP in Canada under different scenarios of intervention coverage. Five-year baseline diabetes risk differed between the lowest and highest income groups by 1.76%. Assuming complete coverage across all income groups, the difference was reduced to 0.90% (144 000 cases prevented) with lifestyle interventions and 1.24% (88 100 cases prevented) with pharmacotherapy. The equity tipping point was estimated to be a coverage difference of 30% for preventive interventions (100% and 70% coverage among the highest and lowest income earners, respectively). Disparities in diabetes risk could be measurably reduced if existing interventions were equally adopted across SEP. However, disparities in coverage could lead to increased inequity in risk. Simple modelling approaches can be used to examine the community effectiveness of individual preventive interventions and their potential to reduce (or increase) disparities. The equity tipping point can be used as a critical threshold for disparities analyses.
Nanostructured Tip-Shaped Biosensors: Application of Six Sigma Approach for Enhanced Manufacturing.
Kahng, Seong-Joong; Kim, Jong-Hoon; Chung, Jae-Hyun
2016-12-23
Nanostructured tip-shaped biosensors have drawn attention for biomolecule detection as they are promising for highly sensitive and specific detection of a target analyte. Using a nanostructured tip, the sensitivity is increased to identify individual molecules because of the high aspect ratio structure. Various detection methods, such as electrochemistry, fluorescence microcopy, and Raman spectroscopy, have been attempted to enhance the sensitivity and the specificity. Due to the confined path of electrons, electrochemical measurement using a nanotip enables the detection of single molecules. When an electric field is combined with capillary action and fluid flow, target molecules can be effectively concentrated onto a nanotip surface for detection. To enhance the concentration efficacy, a dendritic nanotip rather than a single tip could be used to detect target analytes, such as nanoparticles, cells, and DNA. However, reproducible fabrication with relation to specific detection remains a challenge due to the instability of a manufacturing method, resulting in inconsistent shape. In this paper, nanostructured biosensors are reviewed with our experimental results using dendritic nanotips for sequence specific detection of DNA. By the aid of the Six Sigma approach, the fabrication yield of dendritic nanotips increases from 20.0% to 86.6%. Using the nanotips, DNA is concentrated and detected in a sequence specific way with the detection limit equivalent to 1000 CFU/mL. The pros and cons of a nanotip biosensor are evaluated in conjunction with future prospects.
Gaba, Ron C; Shah, Kruti D; Couture, Patrick M; Parvinian, Ahmad; Minocha, Jeet; Knuttinen, M Grace; Bui, James T
2013-01-01
To assess within-patient temporal variability in Model for End Stage Liver Disease (MELD) scores and impact on outcome prognostication after transjugular intrahepatic portosystemic shunt (TIPS) creation. In this single institution retrospective study, MELD score was calculated in 68 patients (M:F = 42:26, mean age 55 years) at 4 pre-procedure time points (1, 2-6, 7-14, and 15-35 days) before TIPS creation. Medical record review was used to identify 30- and 90-day clinical outcomes. Within-patient variability in pre-procedure MELD scores was assessed using repeated measures analysis of variance, and the ability of MELD scores at different time points to predict post-TIPS mortality was evaluated by comparing area under receiver operating characteristic (AUROC) curves. TIPS were successfully created for ascites (n = 30), variceal hemorrhage (n = 29), hepatic hydrothorax (n = 8), and portal vein thrombosis (n = 1). Pre-TIPS MELD scores showed significant (P = 0.032) within-subject variance that approached ± 18.5%. Higher MELD scores demonstrated greater variability in sequential scores as compared to lower MELD scores. Overall 30- and 90-day patient mortality was 22% (15/67) and 38% (24/64). AUROC curves showed that most recent MELD scores performed on the day of TIPS had superior predictive capacity for 30- (0.876, P = 0.037) and 90-day (0.805 P = 0.020) mortality compared to MELD scores performed 2-6 or 7-14 days prior. In conclusion, MELD scores show within-patient variability over time, and scores calculated on the day of TIPS most accurately predict risk and should be used for patient selection and counseling.
Nandre, Rahul M; Ruan, Xiaosai; Duan, Qiangde; Sack, David A; Zhang, Weiping
2016-06-30
Diarrhea continues to be a leading cause of death in children younger than 5 years in developing countries. Enterotoxigenic Escherichia coli (ETEC) is a leading bacterial cause of children's diarrhea and travelers' diarrhea. ETEC bacteria initiate diarrheal disease by attaching to host receptors at epithelial cells and colonizing in small intestine. Therefore, preventing ETEC attachment has been considered the first line of defense against ETEC diarrhea. However, developing vaccines effectively against ETEC bacterial attachment encounters challenge because ETEC strains produce over 23 immunologically heterogeneous adhesins. In this study, we applied MEFA (multiepitope fusion antigen) approach to integrate epitopes from adhesin tips or adhesive subunits of CFA/I, CS1, CS2, CS3, CS4, CS5, CS6, CS21 and EtpA adhesins and to construct an adhesin tip MEFA peptide. We then examined immunogenicity of this tip MEFA in mouse immunization, and assessed potential application of this tip MEFA for ETEC vaccine development. Data showed that mice intraperitoneally immunized with this adhesin tip MEFA developed IgG antibody responses to all nine ETEC adhesins. Moreover, ETEC and E. coli bacteria expressing these nine adhesins, after incubation with serum of the immunized mice, exhibited significant reduction in attachment to Caco-2 cells. These results indicated that anti-adhesin antibodies induced by this adhesin tip MEFA blocked adherence of the most important ETEC adhesins, suggesting this multivalent tip MEFA may be useful for developing a broadly protective anti-adhesin vaccine against ETEC diarrhea. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balke, Nina; Kalinin, Sergei V.; Jesse, Stephen
Kelvin probe force microscopy (KPFM) has provided deep insights into the role local electronic, ionic and electrochemical processes play on the global functionality of materials and devices, even down to the atomic scale. Conventional KPFM utilizes heterodyne detection and bias feedback to measure the contact potential difference (CPD) between tip and sample. This measurement paradigm, however, permits only partial recovery of the information encoded in bias- and time-dependent electrostatic interactions between the tip and sample and effectively down-samples the cantilever response to a single measurement of CPD per pixel. This level of detail is insufficient for electroactive materials, devices, ormore » solid-liquid interfaces, where non-linear dielectrics are present or spurious electrostatic events are possible. Here, we simulate and experimentally validate a novel approach for spatially resolved KPFM capable of a full information transfer of the dynamic electric processes occurring between tip and sample. General acquisition mode, or G-Mode, adopts a big data approach utilising high speed detection, compression, and storage of the raw cantilever deflection signal in its entirety at high sampling rates (> 4 MHz), providing a permanent record of the tip trajectory. We develop a range of methodologies for analysing the resultant large multidimensional datasets involving classical, physics-based and information-based approaches. Physics-based analysis of G-Mode KPFM data recovers the parabolic bias dependence of the electrostatic force for each cycle of the excitation voltage, leading to a multidimensional dataset containing spatial and temporal dependence of the CPD and capacitance channels. We use multivariate statistical methods to reduce data volume and separate the complex multidimensional data sets into statistically significant components that can then be mapped onto separate physical mechanisms. Overall, G-Mode KPFM offers a new paradigm to study dynamic electric phenomena in electroactive interfaces as well as offer a promising approach to extend KPFM to solid-liquid interfaces.« less
Balke, Nina; Kalinin, Sergei V.; Jesse, Stephen; ...
2016-08-12
Kelvin probe force microscopy (KPFM) has provided deep insights into the role local electronic, ionic and electrochemical processes play on the global functionality of materials and devices, even down to the atomic scale. Conventional KPFM utilizes heterodyne detection and bias feedback to measure the contact potential difference (CPD) between tip and sample. This measurement paradigm, however, permits only partial recovery of the information encoded in bias- and time-dependent electrostatic interactions between the tip and sample and effectively down-samples the cantilever response to a single measurement of CPD per pixel. This level of detail is insufficient for electroactive materials, devices, ormore » solid-liquid interfaces, where non-linear dielectrics are present or spurious electrostatic events are possible. Here, we simulate and experimentally validate a novel approach for spatially resolved KPFM capable of a full information transfer of the dynamic electric processes occurring between tip and sample. General acquisition mode, or G-Mode, adopts a big data approach utilising high speed detection, compression, and storage of the raw cantilever deflection signal in its entirety at high sampling rates (> 4 MHz), providing a permanent record of the tip trajectory. We develop a range of methodologies for analysing the resultant large multidimensional datasets involving classical, physics-based and information-based approaches. Physics-based analysis of G-Mode KPFM data recovers the parabolic bias dependence of the electrostatic force for each cycle of the excitation voltage, leading to a multidimensional dataset containing spatial and temporal dependence of the CPD and capacitance channels. We use multivariate statistical methods to reduce data volume and separate the complex multidimensional data sets into statistically significant components that can then be mapped onto separate physical mechanisms. Overall, G-Mode KPFM offers a new paradigm to study dynamic electric phenomena in electroactive interfaces as well as offer a promising approach to extend KPFM to solid-liquid interfaces.« less
A Learning Cycle Approach To Introducing Osmosis.
ERIC Educational Resources Information Center
Lawson, Anton E.
2000-01-01
Presents an inquiry activity with a learning cycle approach to engage students in testing their own hypotheses about how molecules move through cell membranes. Offers student materials and teacher materials, including teaching tips for each phase of the learning cycle. (Contains 11 references.) (ASK)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiefer, Ryan M., E-mail: rkiefer11@gmail.com; Pandey, Nirnimesh; Trerotola, Scott O.
PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tipmore » embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.« less
Volumetric three-component velocimetry measurements of the turbulent flow around a Rushton turbine
NASA Astrophysics Data System (ADS)
Sharp, Kendra V.; Hill, David; Troolin, Daniel; Walters, Geoffrey; Lai, Wing
2010-01-01
Volumetric three-component velocimetry measurements have been taken of the flow field near a Rushton turbine in a stirred tank reactor. This particular flow field is highly unsteady and three-dimensional, and is characterized by a strong radial jet, large tank-scale ring vortices, and small-scale blade tip vortices. The experimental technique uses a single camera head with three apertures to obtain approximately 15,000 three-dimensional vectors in a cubic volume. These velocity data offer the most comprehensive view to date of this flow field, especially since they are acquired at three Reynolds numbers (15,000, 107,000, and 137,000). Mean velocity fields and turbulent kinetic energy quantities are calculated. The volumetric nature of the data enables tip vortex identification, vortex trajectory analysis, and calculation of vortex strength. Three identification methods for the vortices are compared based on: the calculation of circumferential vorticity; the calculation of local pressure minima via an eigenvalue approach; and the calculation of swirling strength again via an eigenvalue approach. The use of two-dimensional data and three-dimensional data is compared for vortex identification; a `swirl strength' criterion is less sensitive to completeness of the velocity gradient tensor and overall provides clearer identification of the tip vortices. The principal components of the strain rate tensor are also calculated for one Reynolds number case as these measures of stretching and compression have recently been associated with tip vortex characterization. Vortex trajectories and strength compare favorably with those in the literature. No clear dependence of trajectory on Reynolds number is deduced. The visualization of tip vortices up to 140° past blade passage in the highest Reynolds number case is notable and has not previously been shown.
Fracture Mechanics Analyses for Interface Crack Problems - A Review
NASA Technical Reports Server (NTRS)
Krueger, Ronald; Shivakumar, Kunigal; Raju, Ivatury S.
2013-01-01
Recent developments in fracture mechanics analyses of the interfacial crack problem are reviewed. The intent of the review is to renew the awareness of the oscillatory singularity at the crack tip of a bimaterial interface and the problems that occur when calculating mode mixity using numerical methods such as the finite element method in conjunction with the virtual crack closure technique. Established approaches to overcome the nonconvergence issue of the individual mode strain energy release rates are reviewed. In the recent literature many attempts to overcome the nonconvergence issue have been developed. Among the many approaches found only a few methods hold the promise of providing practical solutions. These are the resin interlayer method, the method that chooses the crack tip element size greater than the oscillation zone, the crack tip element method that is based on plate theory and the crack surface displacement extrapolation method. Each of the methods is validated on a very limited set of simple interface crack problems. However, their utility for a wide range of interfacial crack problems is yet to be established.
Infrared Thermal Imaging During Ultrasonic Aspiration of Bone
NASA Astrophysics Data System (ADS)
Cotter, D. J.; Woodworth, G.; Gupta, S. V.; Manandhar, P.; Schwartz, T. H.
Ultrasonic surgical aspirator tips target removal of bone in approaches to tumors or aneurysms. Low profile angled tips provide increased visualization and safety in many high risk surgical situations that commonly were approached using a high speed rotary drill. Utilization of the ultrasonic aspirator for bone removal raised questions about relative amount of local and transmitted heat energy. In the sphenoid wing of a cadaver section, ultrasonic bone aspiration yielded lower thermal rise in precision bone removal than rotary mechanical drills, with maximum temperature of 31 °C versus 69 °C for fluted and 79 °C for diamond drill bits. Mean ultrasonic fragmentation power was about 8 Watts. Statistical studies using tenacious porcine cranium yielded mean power levels of about 4.5 Watts to 11 Watts and mean temperature of less than 41.1 °C. Excessively loading the tip yielded momentary higher power; however, mean thermal rise was less than 8 °C with bone removal starting at near body temperature of about 37 °C. Precision bone removal and thermal management were possible with conditions tested for ultrasonic bone aspiration.
Numerical Analysis of Crack Tip Plasticity and History Effects under Mixed Mode Conditions
NASA Astrophysics Data System (ADS)
Lopez-Crespo, Pablo; Pommier, Sylvie
The plastic behaviour in the crack tip region has a strong influence on the fatigue life of engineering components. In general, residual stresses developed as a consequence of the plasticity being constrained around the crack tip have a significant role on both the direction of crack propagation and the propagation rate. Finite element methods (FEM) are commonly employed in order to model plasticity. However, if millions of cycles need to be modelled to predict the fatigue behaviour of a component, the method becomes computationally too expensive. By employing a multiscale approach, very precise analyses computed by FEM can be brought to a global scale. The data generated using the FEM enables us to identify a global cyclic elastic-plastic model for the crack tip region. Once this model is identified, it can be employed directly, with no need of additional FEM computations, resulting in fast computations. This is done by partitioning local displacement fields computed by FEM into intensity factors (global data) and spatial fields. A Karhunen-Loeve algorithm developed for image processing was employed for this purpose. In addition, the partitioning is done such as to distinguish into elastic and plastic components. Each of them is further divided into opening mode and shear mode parts. The plastic flow direction was determined with the above approach on a centre cracked panel subjected to a wide range of mixed-mode loading conditions. It was found to agree well with the maximum tangential stress criterion developed by Erdogan and Sih, provided that the loading direction is corrected for residual stresses. In this approach, residual stresses are measured at the global scale through internal intensity factors.
Fronczak, Sean G; Dong, Jiannan; Browne, Christopher A; Krenek, Elizabeth C; Franses, Elias I; Beaudoin, Stephen P; Corti, David S
2017-01-24
In order to minimize the effects of surface roughness and deformation, a new method for estimating the Hamaker constant, A, of solids using the approach-to-contact regime of an atomic force microscope (AFM) is presented. First, a previous "jump-into-contact" quasi-static method for determining A from AFM measurements is analyzed and then extended to include various AFM tip-surface force models of interest. Then, to test the efficacy of the "jump-into-contact" method, a dynamic model of the AFM tip motion is developed. For finite AFM cantilever-surface approach speeds, a true "jump" point, or limit of stability, is found not to appear, and the quasi-static model fails to represent the dynamic tip behavior at close tip-surface separations. Hence, a new "quasi-dynamic" method for estimating A is proposed that uses the dynamically well-defined deflection at which the tip and surface first come into contact, d c , instead of the dynamically ill-defined "jump" point. With the new method, an apparent Hamaker constant, A app , is calculated from d c and a corresponding quasi-static-based equation. Since A app depends on the cantilever's approach speed, v c , and the AFM's sampling resolution, δ, a double extrapolation procedure is used to determine A app in the quasi-static (v c → 0) and continuous sampling (δ → 0) limits, thereby recovering the "true" value of A. The accuracy of the new method is validated using simulated AFM data. To enable the experimental implementation of this method, a new dimensionless parameter τ is introduced to guide cantilever selection and the AFM operating conditions. The value of τ quantifies how close a given cantilever is to its quasi-static limit for a chosen cantilever-surface approach speed. For sufficiently small values of τ (i.e., a cantilever that effectively behaves "quasi-statically"), simulated data indicate that A app will be within ∼3% or less of the inputted value of the Hamaker constant. This implies that Hamaker constants can be reliably estimated using a single measurement taken with an appropriately chosen cantilever and a slow, yet practical, approach speed (with no extrapolation required). This result is confirmed by the very good agreement found between the experimental AFM results obtained using this new method and previously reported predictions of A for amorphous silica, polystyrene, and α-Al 2 O 3 substrates obtained using the Lifshitz method.
Golwala, Sohil N; Vance, Ansar Z; Tuerff, Sonya N
2016-01-01
Introduction In symptomatic subclavian steal syndrome, endovascular treatment is the first line of therapy prior to extra-anatomic surgical bypass procedures. Subintimal recanalization has been well described in the literature for the coronary arteries, and more recently, in the lower extremities. By modifying this approach, we present a unique retrograde technique using a heavy tip microwire to perform controlled subintimal dissection. Methods We present two cases of symptomatic subclavian steal related to chronic total occlusion of the left subclavian artery and right innominate artery, respectively. Standard crossing techniques were unsuccessful. Commonly at this point, the procedures would be aborted and open surgical intervention would have to be pursued. In our cases, retrograde access was easily achieved via an ipsilateral retrograde radial artery, using controlled subintimal dissection and a heavy-tipped wire. Results We were able to easily achieve recanalization in both attempted cases of chronic total occlusion of the subclavian and innominate artery, using a retrograde radial subintimal approach. Subsequent stent-supported angioplasty resulted in complete revascularization. No major complications were encountered during the procedures; however, one patient did develop thromboembolic stroke secondary to platelet aggregation to the stent graft, 9 days post-procedure. Conclusions Endovascular treatment is considered the first-line intervention in medically refractory patients with symptomatic subclavian steal syndrome. In the setting of chronic total occlusions, a retrograde radial subintimal approach using a heavy tip wire for controlled subintimal dissection is a novel technique that may be considered when standard approaches and wires have failed. PMID:26861024
Huntington, Henry P; Goodstein, Eban; Euskirchen, Eugénie
2012-02-01
Climate change incurs costs, but government adaptation budgets are limited. Beyond a certain point, individuals must bear the costs or adapt to new circumstances, creating political-economic tipping points that we explore in three examples. First, many Alaska Native villages are threatened by erosion, but relocation is expensive. To date, critically threatened villages have not yet been relocated, suggesting that we may already have reached a political-economic tipping point. Second, forest fires shape landscape and ecological characteristics in interior Alaska. Climate-driven changes in fire regime require increased fire-fighting resources to maintain current patterns of vegetation and land use, but these resources appear to be less and less available, indicating an approaching tipping point. Third, rapid sea level rise, for example from accelerated melting of the Greenland ice sheet, will create a choice between protection and abandonment for coastal regions throughout the world, a potential global tipping point comparable to those now faced by Arctic communities. The examples illustrate the basic idea that if costs of response increase more quickly than available resources, then society has fewer and fewer options as time passes.
Optical probe for determining the fat/lean interface in cuts of meat
Weber, Thomas M.; Callow, Diane S.; Jones, James F.; Kuehl, Michael A.; Spletzer, Barry L.
2005-02-22
An apparatus and method for locating the boundary surface between a layer of fatty tissue and lean tissue in a cut of meat, such as beef, such as slabs of meat undergoing trimming and cutting in commercial meet processing facilitates. The invention exploits the fact that fatty tissue and lean tissue have significantly different responses to incident light energy. By gauging the degree to which a generated beam of light is scattered and reflected by the tissues under evaluation, the invention permits the character of the tissue to be ascertained. An incident beam of light, such as green light, is generated and transmitted to a probe tip, which tip is inserted into the cut of meat under investigation. The light beam is emitted into the meat tissues from the probe tip, and then is scattered and reflected by the tissues, whereupon some fraction of the emitted light returns to the probe tip. The returning light energy is transmitted to a detector; relative changes in the returning light transmitted to the detector permit the operator to determine when the probe tip is approaching or penetrating the fat/lean tissue interface.
Mechanical manipulation of magnetic nanoparticles by magnetic force microscopy
NASA Astrophysics Data System (ADS)
Liu, Jinyun; Zhang, Wenxiao; Li, Yiquan; Zhu, Hanxing; Qiu, Renxi; Song, Zhengxun; Wang, Zuobin; Li, Dayou
2017-12-01
A method has been developed in this work for the mechanical manipulation of magnetic nanoparticles (MNPs). A helical curve was designed as the capture path to pick up and remove the target nanoparticle on a mica surface by a magnetic probe based on the magnetic force microscope (MFM). There were magnetic, tangential and pushing forces acting on the target particle during the approaching process when the tip followed the helical curve as the capture path. The magnetic force was significant when the tip was closer to the particle. The target particle can be attached on the surface of the magnetic probe tip and then be picked up after the tip retracted from the mica surface. Theoretical analysis and experimental results were presented for the pick-up and removal of MNPs. With this method, the precision and flexibility of manipulation of MNPs were improved significantly compared to the pushing or sliding of the target object away from the corresponding original location following a planned path.
Imaging thermal conductivity with nanoscale resolution using a scanning spin probe
Laraoui, Abdelghani; Aycock-Rizzo, Halley; Gao, Yang; ...
2015-11-20
The ability to probe nanoscale heat flow in a material is often limited by lack of spatial resolution. Here, we use a diamond-nanocrystal-hosted nitrogen-vacancy centre attached to the apex of a silicon thermal tip as a local temperature sensor. We apply an electrical current to heat up the tip and rely on the nitrogen vacancy to monitor the thermal changes the tip experiences as it is brought into contact with surfaces of varying thermal conductivity. By combining atomic force and confocal microscopy, we image phantom microstructures with nanoscale resolution, and attain excellent agreement between the thermal conductivity and topographic maps.more » The small mass and high thermal conductivity of the diamond host make the time response of our technique short, which we demonstrate by monitoring the tip temperature upon application of a heat pulse. Our approach promises multiple applications, from the investigation of phonon dynamics in nanostructures to the characterization of heterogeneous phase transitions and chemical reactions in various solid-state systems.« less
Amini, Abbas; Cheng, Chun
2013-01-01
Due to a distinct nature of thermomechanical smart materials' reaction to applied loads, a revolutionary approach is needed to measure the hardness and to understand its size effect for pseudoelastic NiTi shape memory alloys (SMAs) during the solid-state phase transition. Spherical hardness is increased with depths during the phase transition in NiTi SMAs. This behaviour is contrary to the decrease in the hardness of NiTi SMAs with depths using sharp tips and the depth-insensitive hardness of traditional metallic alloys using spherical tips. In contrast with the common dislocation theory for the hardness measurement, the nature of NiTi SMAs' hardness is explained by the balance between the interface and the bulk energy of phase transformed SMAs. Contrary to the energy balance in the indentation zone using sharp tips, the interface energy was numerically shown to be less dominant than the bulk energy of the phase transition zone using spherical tips. PMID:23963305
Completo, A; Fonseca, F; Simões, J A; Ramos, A; Relvas, C
2012-10-01
Revision total knee arthroplasty presents numerous technical challenges, with lower patient outcomes compared with those obtained in primary surgery. Extended stems have been used in revision total knee arthroplasty to improve component alignment and fixation. Hybrid fixation with cemented tibial tray and press-fit stem has shown good results. One of the disadvantages of this technique is pain related to the presence of a cementless diaphyseal engaging stem, often designated as end-of-stem pain. Patients with this pain have reported a decrease in overall satisfaction, as well as demonstrate a lower clinical outcome score. Clinical findings suggest that stem material and design are important factors in the development of end-of-stem pain. Therefore, a question can be raised: can a novel press-fit stem concept minimize bone strain changes at the stem tip? The hypothesis here considered lies upon the fact, that if periosteal cortex strain changes are minimized at the stem tip comparatively to the intact situation, the risk of end-of-stem pain might be minimized. This pre-clinical study was accomplished using synthetic tibiae to experimentally predict the periosteal cortex strains at the proximal and stem tip regions, with a commercial press-fit stem and a new stem concept. The results demonstrated that the new stem concept has the ability to minimize strain changes induced by the stem tip at the distal periosteal cortex and consequently, at the periosteal layer of bone tissue, which is highly pain sensitive, probably contributing to the reduction of the risk of end-of-stem pain. Copyright © 2012 Elsevier B.V. All rights reserved.
Shivalli, Siddharudha; Srivastava, Ratan Kumar; Singh, Gyan Prakash
2015-01-01
Behavior Change Communications (BCC) play a decisive role in modifying socio-cultural norms affecting the perception and nutritional practices during pregnancy. To examine the effectiveness of 'Trials of Improved Practices' (TIPs) on dietary and iron-folate intake during pregnancy. Community based quasi experimental study with a control group. Four villages of Chiraigaon Community Development Block of Varanasi, India from May 2010 and recruited from August 2010. End line assessment, after 12 weeks of intervention, was completed in April 2011. Pregnant women in 13-28 weeks of gestation. TIPs was implemented in addition to ongoing essential obstetric care services in two villages through 3 home (assessment, negotiation and evaluation) visits and only assessment and evaluation visits in the other two control villages. Interpersonal communication, endorsing the active participation of family members and home based reminder materials were the TIPs based strategies. The effect of TIPs was assessed by comparing key outcome variables at baseline and after 12 weeks of intervention. Hemoglobin%, anemia prevalence, weight gain, compliance for iron-folate supplementation and dietary intake of calorie, protein, calcium and iron. A total of 86 participants completed the study. At the end, mean hemoglobin levels were 11.5±1.24 g/dl and 10.37±1.38 g/dl in the TIPs and control groups, respectively. The prevalence of anemia reduced by half in TIPs group and increased by 2.4% in the control group. Weight gain (grams/week) was significantly (p<0.01) higher in TIPs group (326.9±91.8 vs. 244.6±97.4). More than 85% of the PW in TIPs group were compliant for Iron-folate and only 38% were compliant among controls. The mean intake of protein increased by 1.78gm in intervention group and decreased by 1.81 gm in controls (p<0.05). More than two thirds of PW in TIPs group were taking one extra meal and only one third of controls were doing the same. TIPs found to be an effective approach to improve the nutritional status of pregnant women in the study area. TIPs strategy could be further explored on larger sample representing different socio-cultural and geographical areas. Clinical Trial Registry of India CTRI/2015/02/005517.
Nioradze, Nikoloz; Kim, Jiyeon; Amemiya, Shigeru
2011-02-01
We report on a novel theory and experiment for scanning electrochemical microscopy (SECM) to enable quasi-steady-state voltammetry of rapid electron transfer (ET) reactions at macroscopic substrates. With this powerful approach, the substrate potential is cycled widely across the formal potential of a redox couple while the reactant or product of a substrate reaction is amperometrically detected at the tip in the feedback or substrate generation/tip collection mode, respectively. The plot of tip current versus substrate potential features the retraceable sigmoidal shape of a quasi-steady-state voltammogram although a transient voltammogram is obtained at the macroscopic substrate. Finite element simulations reveal that a short tip-substrate distance and a reversible substrate reaction (except under the tip) are required for quasi-steady-state voltammetry. Advantageously, a pair of quasi-steady-state voltammograms is obtained by employing both operation modes to reliably determine all transport, thermodynamic, and kinetic parameters as confirmed experimentally for rapid ET reactions of ferrocenemethanol and 7,7,8,8-tetracyanoquinodimethane at a Pt substrate with ∼0.5 μm-radius Pt tips positioned at 90 nm-1 μm distances. Standard ET rate constants of ∼7 cm/s were obtained for the latter mediator as the largest determined for a substrate reaction by SECM. Various potential applications of quasi-steady-state voltammetry are also proposed.
Walke, Peter; Fujita, Yasuhiko; Peeters, Wannes; Toyouchi, Shuichi; Frederickx, Wout; De Feyter, Steven; Uji-I, Hiroshi
2018-04-26
Tip-enhanced Raman scattering (TERS) microscopy is a unique analytical tool to provide complementary chemical and topographic information of surfaces with nanometric resolution. However, difficulties in reliably producing the necessary metallized scanning probe tips has limited its widespread utilisation, particularly in the case of cantilever-based atomic force microscopy. Attempts to alleviate tip related issues using colloidal or bottom-up engineered tips have so far not reported consistent probes for both Raman and topographic imaging. Here we demonstrate the reproducible fabrication of cantilever-based high-performance TERS probes for both topographic and Raman measurements, based on an approach that utilises noble metal nanowires as the active TERS probe. The tips show 10 times higher TERS contrasts than the most typically used electrochemically-etched tips, and show a reproducibility for TERS greater than 90%, far greater than found with standard methods. We show that TERS can be performed in tapping as well as contact AFM mode, with optical resolutions around or below 15 nm, and with a maximum resolution achieved in tapping-mode of 6 nm. Our work illustrates that superior TERS probes can be produced in a fast and cost-effective manner using simple wet-chemistry methods, leading to reliable and reproducible high-resolution and high-sensitivity TERS, and thus renders the technique applicable for a broad community.
Outreach to Inspire Girls in Geology: A Recipe for Success (Invited)
NASA Astrophysics Data System (ADS)
Kekelis, L.
2010-12-01
Geology and engineering careers can seem very abstract to a young girl, especially to a girl who has no role model in technical fields. Many girls want to make the world a better place but don’t see how their interests connect with geology or engineering. Role models and field trips to worksites are instrumental in encouraging girls to consider careers in geoscience and engineering. The opportunities to see real-world applications of technology and meet with role models who work in technical fields are extremely impactful and can have a strong influence on a girl’s career path. Together we need to do a better job of communicating what geoscience and engineering have to offer girls and what girls have to offer these fields. This presentation will provide practical tips to help combat stereotypes, 2) share resources for outreach at one-day special events, summer camps, visits to the classroom and field trips to corporate sites and college campuses, and 3) highlight strategies for groups to work collaboratively in outreach. This presentation will help those currently involved in outreach who want to improve on existing efforts, along with those who have never done outreach and are interested in getting started. Techbridge will share a “recipe for success” for planning and hosting role model visits to the classroom and field trips. A case study of outreach by Chevron with Techbridge girls will be shared including the pre-event planning that made this event a success. Activities that make geology fun and friendly to girls and tips for dispelling stereotypes about careers in geology and engineering will also be shared. Participants will be invited to ask questions and share on topics of interest, such as “Challenges with outreach,” “How to get involved without burning out,” and “How to show your manager or organization that outreach is worth the effort.” We will also promote a candid discussion of the challenges that can arise along with way and how to overcome them. Participants will receive a copy of our role model outreach guide and CD toolkit, Get Involved. Make a Difference, developed by the Techbridge team. This guide includes practical tips and suggestions as well as successful case studies in outreach to K-12. These materials include sample icebreakers and hands-on activities, biographies of students and role models, questions to facilitate conversations between role models and students, scavenger hunts for tours, suggested schedule and timeline, evaluations, tips for success, and more.
Overview of hybridization and detection techniques.
Hilario, Elena
2007-01-01
A misconception regarding the sensitivity of nonradioactive methods for screening genomic DNA libraries often hinders the establishment of these environmentally friendly techniques in molecular biology laboratories. Nonradioactive probes, properly prepared and quantified, can detect DNA target molecules to the femtomole range. However, appropriate hybridization techniques and detection methods should also be adopted for an efficient use of nonradioactive techniques. Detailed descriptions of genomic library handling before and during the nonradioactive hybridization and detection are often omitted from publications. This chapter aims to fill this void by providing a collection of technical tips on hybridization and detection techniques.
How to prepare and submit abstracts for scientific meetings
Japiassú, Andre Miguel
2013-01-01
The presentation of study results is a key step in scientific research, and submitting an abstract to a meeting is often the first form of public communication. Meeting abstracts have a defined structure that is similar to abstracts for scientific articles, with an introduction, the objective, methods, results and conclusions. However, abstracts for meetings are not presented as part of a full article and, therefore, must contain the necessary and most relevant data. In this article, we detail their structure and include tips to make them technically correct. PMID:23917970
How to prepare and submit abstracts for scientific meetings.
Japiassú, Andre Miguel
2013-01-01
The presentation of study results is a key step in scientific research, and submitting an abstract to a meeting is often the first form of public communication. Meeting abstracts have a defined structure that is similar to abstracts for scientific articles, with an introduction, the objective, methods, results and conclusions. However, abstracts for meetings are not presented as part of a full article and, therefore, must contain the necessary and most relevant data. In this article, we detail their structure and include tips to make them technically correct.
EEE Links, Volume 9, No. 1, January 2003 Focus on Plastic Parts
NASA Technical Reports Server (NTRS)
2003-01-01
The January 2003 issue of Electronic, Electromechanical, Electric (EEE) Links is presented. The Programmable Logic Application Notes column has been reinstated in this newsletter. Written by Rich Katz of NASA's Office of Logic Design (OLD), the application notes offer technical tips intended to prevent flight design errors and enhance research, development, and use of programmable logic and elements for space flight applications. An archive of these notes columns from previous issues of EEE Links is available at http://www.klabs.org/richcontent/eeelink s/EEE Links.htm.
Visualization and Quantification of Rotor Tip Vortices in Helicopter Flows
NASA Technical Reports Server (NTRS)
Kao, David L.; Ahmad, Jasim U.; Holst, Terry L.
2015-01-01
This paper presents an automated approach for effective extraction, visualization, and quantification of vortex core radii from the Navier-Stokes simulations of a UH-60A rotor in forward flight. We adopt a scaled Q-criterion to determine vortex regions and then perform vortex core profiling in these regions to calculate vortex core radii. This method provides an efficient way of visualizing and quantifying the blade tip vortices. Moreover, the vortices radii are displayed graphically in a plane.
2015-04-23
blade geometry parameters the TPL design 9 tool was initiated by running the MATLAB script (*.m) Main_SpeedLine_Auto. Main_SpeedLine_Auto...SolidWorks for solid model generation of the blade shapes. Computational Analysis With solid models generated of the gas -path air wedge, automated...287 mm (11.3 in) Constrained by existing TCR geometry Number of Passages 12 None A blade tip-down design approach was used. The outputs of the
Fuel conservation through active control of rotor clearances
NASA Technical Reports Server (NTRS)
Beitler, R. S.; Saunders, A. A.; Wanger, R. P.
1980-01-01
Under the NASA-sponsored Energy Efficient Engine (EEE) Project, technology is being developed which will significantly reduce the fuel consumption of turbofan engines for subsonic transport aircraft. One technology concept being pursued is active control of rotor tip clearances. Attention is given to rotor tip clearance considerations and an overview of preliminary study results as well as the General Electric EEE clearance control approach is presented. Finally, potential fuel savings with active control of rotor clearances for a typical EEE mission are predicted.
Sharifi, M; Lauer, J; Pompili, V J; Dillon, J C
1999-11-01
In this report, we describe an alternative method to the conventional arteriographic techniques of the left internal mammary artery (LIMA) graft using a balloon-tipped floatation catheter placed within the left subclavian artery. The floatation catheter will serve as both an occluder of the subclavian artery as well as a port for contrast injection. It may be effectively employed in the rare instances where direct cannulation of the LIMA graft is not possible.
Regnault, David; d'Alteroche, Louis; Nicolas, Charlotte; Dujardin, Fanny; Ayoub, Jean; Perarnau, Jean Marc
2018-05-01
Transjugular intrahepatic portosystemic shunt (TIPS) is considered to be well suited for the treatment of noncirrhotic portal hypertension (NCPHT) because of a usually severe portal hypertension (PHT) and a mild liver failure, but very less data are available. Records of patients referred for TIPS between 2004 and 2015 for NCPHT were reviewed. No patient should have clinical or biological or histological features of cirrhosis. Twenty-five patients with a wide variety of histological lesions (sinusoidal dilatations, granulomatosis, regenerative nodular hyperplasia, obliterative portal venopathy, or subnormal liver) and a wide variety of associated diseases (thrombophilia, sarcoidosis, common variable immunodeficiency, scleroderma, Castleman's disease, early primitive biliary cirrhosis, congenital liver fibrosis, chemotherapy, purinethol intake, and congenital varices) were included. Two complications occurred during the procedure: one periprosthetic hematoma and the other misposition of a covered stent. During the first month, two other patients had an early thrombosis, another had induced encephalopathy, and one died of early rebleeding. Two of these complications occurred in patients with cavernoma. With a mean follow-up of 39 months, 10 patients experienced at least one episode of spontaneous encephalopathy, with three of these patients requiring a stent reduction. Five patients had a recurrence of their initial symptoms, and one had an asymptomatic hemodynamic dysfunction. TIPS is effective in NCPHT but can be technically difficult, especially in the case of cavernoma. Good liver function does not prevent the occurrence of long-term encephalopathy.
NASA Astrophysics Data System (ADS)
Wang, Wei; Wang, Liang; Dai, Gaole; Deng, Wei; Zhang, Xiujuan; Jie, Jiansheng; Zhang, Xiaohong
2017-10-01
Organic field-effect transistors (OFETs) based on organic micro-/nanocrystals have been widely reported with charge carrier mobility exceeding 1.0 cm2 V-1 s-1, demonstrating great potential for high-performance, low-cost organic electronic applications. However, fabrication of large-area organic micro-/nanocrystal arrays with consistent crystal growth direction has posed a significant technical challenge. Here, we describe a solution-processed dip-coating technique to grow large-area, aligned 9,10-bis(phenylethynyl) anthracene (BPEA) and 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-PEN) single-crystalline nanoribbon arrays. The method is scalable to a 5 × 10 cm2 wafer substrate, with around 60% of the wafer surface covered by aligned crystals. The quality of crystals can be easily controlled by tuning the dip-coating speed. Furthermore, OFETs based on well-aligned BPEA and TIPS-PEN single-crystalline nanoribbons were constructed. By optimizing channel lengths and using appropriate metallic electrodes, the BPEA and TIPS-PEN-based OFETs showed hole mobility exceeding 2.0 cm2 V-1 s-1 (average mobility 1.2 cm2 V-1 s-1) and 3.0 cm2 V-1 s-1 (average mobility 2.0 cm2 V-1 s-1), respectively. They both have a high on/off ratio ( I on/ I off) > 109. The performance can well satisfy the requirements for light-emitting diodes driving.
The Microstructural Evolution of Fatigue Cracks in FCC Metals
NASA Astrophysics Data System (ADS)
Gross, David William
The microstructural evolution during fatigue crack propagation was investigated in a variety of planar and wavy slip FCC metals. The planar materials included Haynes 230, Nitronic 40, and 316 stainless steel, and the wavy materials included pure nickel and pure copper. Three different sets of experiments were performed to fully characterize the microstructural evolution. The first, performed on Haynes 230, mapped the strain field ahead a crack tip using digital image correlation and electron backscatter diffraction techniques. Focused ion beam (FIB) lift-out techniques were then utilized to extract transmission electron microscopy (TEM) samples at specific distances from the crack tip. TEM investigations compared the measured strain to the microstructure. Overall, the strain measured via DIC and EBSD was only weakly correlated to the density of planar slip bands in the microstructure. The second set of experiments concerned the dislocation structure around crack tips. This set of experiments was performed on all the materials. The microstructure at arrested fatigue cracks on the free surface was compared to the microstructure found beneath striations on the fracture surfaces by utilizing FIB micromachining to create site-specific TEM samples. The evolved microstructure depended on the slip type. Strong agreement was found between the crack tip microstructure at the free surface and the fracture surface. In the planar materials, the microstructure in the plastic zone consisted of bands of dislocations or deformation twins, before transitioning to a refined sub-grain microstructure near the crack flank. The sub-grain structure extended 300-500 nm away from the crack flank in all the planar slip materials studied. In contrast, the bulk structure in the wavy slip material consisted of dislocation cells and did not transition to a different microstructure as the crack tip was approached. The strain in wavy slip was highest near the crack tip, as the misorientations between the dislocation cells increased and the cell size decreased as the crack flank was approached. The final set of experiments involved reloading the arrested crack tips in monotonic tension. This was performed on both the Haynes 230 and 316 stainless steel. This technique exposed the fracture surface and location of the arrested crack tip away from the free surface, allowing for a sample to be extracted via FIB micromachining and TEM evaluation of the microstructure. This permitted the crack tip microstructure to be investigated without exposing the microstructure to crack closure or free surface effects. These experiments confirmed what was inferred from the earlier experiments, namely that the banded structure was a product of the crack tip plastic zone and the refined structure was a product of the strain associated with crack advance. Overall the microstructural complexity presented in this work was much higher than would be predicted by current models of fatigue crack propagation. It is recommended that future models attempt to simulate interactions between the dislocations emitted during fatigue crack growth and the pre-existing microstructure to more accurately simulate the processes occurring at the crack tip during crack growth.
Finite Element Model and Validation of Nasal Tip Deformation
Manuel, Cyrus T; Harb, Rani; Badran, Alan; Ho, David; Wong, Brian JF
2016-01-01
Nasal tip mechanical stability is important for functional and cosmetic nasal airway surgery. Palpation of the nasal tip provides information on tip strength to the surgeon, though it is a purely subjective assessment. Providing a means to simulate nasal tip deformation with a validated model can offer a more objective approach in understanding the mechanics and nuances of the nasal tip support and eventual nasal mechanics as a whole. Herein we present validation of a finite element (FE) model of the nose using physical measurements recorded using an ABS plastic-silicone nasal phantom. Three-dimensional photogrammetry was used to capture the geometry of the phantom at rest and while under steady state load. The silicone used to make the phantom was mechanically tested and characterized using a linear elastic constitutive model. Surface point clouds of the silicone and FE model were compared for both the loaded and unloaded state. The average Hausdorff distance between actual measurements and FE simulations across the nose were 0.39mm ± 1.04 mm and deviated up to 2mm at the outermost boundaries of the model. FE simulation and measurements were in near complete agreement in the immediate vicinity of the nasal tip with millimeter accuracy. We have demonstrated validation of a two-component nasal FE model, which could be used to model more complex modes of deformation where direct measurement may be challenging. This is the first step in developing a nasal model to simulate nasal mechanics and ultimately the interaction between geometry and airflow. PMID:27633018
Finite Element Model and Validation of Nasal Tip Deformation.
Manuel, Cyrus T; Harb, Rani; Badran, Alan; Ho, David; Wong, Brian J F
2017-03-01
Nasal tip mechanical stability is important for functional and cosmetic nasal airway surgery. Palpation of the nasal tip provides information on tip strength to the surgeon, though it is a purely subjective assessment. Providing a means to simulate nasal tip deformation with a validated model can offer a more objective approach in understanding the mechanics and nuances of the nasal tip support and eventual nasal mechanics as a whole. Herein we present validation of a finite element (FE) model of the nose using physical measurements recorded using an ABS plastic-silicone nasal phantom. Three-dimensional photogrammetry was used to capture the geometry of the phantom at rest and while under steady state load. The silicone used to make the phantom was mechanically tested and characterized using a linear elastic constitutive model. Surface point clouds of the silicone and FE model were compared for both the loaded and unloaded state. The average Hausdorff distance between actual measurements and FE simulations across the nose were 0.39 ± 1.04 mm and deviated up to 2 mm at the outermost boundaries of the model. FE simulation and measurements were in near complete agreement in the immediate vicinity of the nasal tip with millimeter accuracy. We have demonstrated validation of a two-component nasal FE model, which could be used to model more complex modes of deformation where direct measurement may be challenging. This is the first step in developing a nasal model to simulate nasal mechanics and ultimately the interaction between geometry and airflow.
A statistical approach for generating synthetic tip stress data from limited CPT soundings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basalams, M.K.
CPT tip stress data obtained from a Uranium mill tailings impoundment are treated as time series. A statistical class of models that was developed to model time series is explored to investigate its applicability in modeling the tip stress series. These models were developed by Box and Jenkins (1970) and are known as Autoregressive Moving Average (ARMA) models. This research demonstrates how to apply the ARMA models to tip stress series. Generation of synthetic tip stress series that preserve the main statistical characteristics of the measured series is also investigated. Multiple regression analysis is used to model the regional variationmore » of the ARMA model parameters as well as the regional variation of the mean and the standard deviation of the measured tip stress series. The reliability of the generated series is investigated from a geotechnical point of view as well as from a statistical point of view. Estimation of the total settlement using the measured and the generated series subjected to the same loading condition are performed. The variation of friction angle with depth of the impoundment materials is also investigated. This research shows that these series can be modeled by the Box and Jenkins ARMA models. A third degree Autoregressive model AR(3) is selected to represent these series. A theoretical double exponential density function is fitted to the AR(3) model residuals. Synthetic tip stress series are generated at nearby locations. The generated series are shown to be reliable in estimating the total settlement and the friction angle variation with depth for this particular site.« less
The Hardy-Weinberg Equilibrium--Some Helpful Suggestions.
ERIC Educational Resources Information Center
Ortiz, Mary T.; Taras, Loretta; Stavroulakis, Anthea M.
2000-01-01
Describes an approach that provides mathematical tips and helpful suggestions for presenting the Hardy-Weinberg equilibrium to predict allele frequencies, phenotypes, and genotypes in populations. (ASK)
Are you Scared Yet?: Evaluating Fear Appeal Messages in Tweets about the Tips Campaign.
Emery, Sherry L; Szczypka, Glen; Abril, Eulàlia Puig; Kim, Yoonsang; Vera, Lisa
2014-04-01
In March 2012, the CDC launched "Tips from Former Smokers," a $54 million national campaign featuring individuals experiencing long-term health consequences of smoking. The campaign approach was based on strong evidence that anti-tobacco ads portraying fear, graphic images, and personal testimonials are associated with attitudinal and behavior change. Yet it was also controversial; critics cited the danger that viewers might reject such intensely graphic messages. Tasked with informing this debate, our study analyzes the corpus of Tips campaign-related tweets obtained via the Twitter Firehose. We provide a novel and rigorous method for media campaign evaluation within the framework of the Extended Parallel Process Model. Among the relevant Tweets, 87% showed evidence of message acceptance, while 7% exhibited message rejection.
Ultra compact multitip scanning tunneling microscope with a diameter of 50 mm.
Cherepanov, Vasily; Zubkov, Evgeny; Junker, Hubertus; Korte, Stefan; Blab, Marcus; Coenen, Peter; Voigtländer, Bert
2012-03-01
We present a multitip scanning tunneling microscope (STM) where four independent STM units are integrated on a diameter of 50 mm. The coarse positioning of the tips is done under the control of an optical microscope or scanning electron microscopy in vacuum. The heart of this STM is a new type of piezoelectric coarse approach called KoalaDrive. The compactness of the KoalaDrive allows building a four-tip STM as small as a single-tip STM with a drift of less than 0.2 nm/min at room temperature and lowest resonance frequencies of 2.5 kHz (xy) and 5.5 kHz (z). We present as examples of the performance of the multitip STM four point measurements of silicide nanowires and graphene.
ERIC Educational Resources Information Center
Jones, Natasha N.
2016-01-01
This article argues for the need for a social justice approach to technical communication research and pedagogy. Given previous calls by scholars in technical and professional communication (TPC) for an attention to diversity, inclusion, and equality, the author examines the place and purpose of social justice in TPC and provides useful approaches…
Nanostructured Tip-Shaped Biosensors: Application of Six Sigma Approach for Enhanced Manufacturing
Kahng, Seong-Joong; Kim, Jong-Hoon; Chung, Jae-Hyun
2016-01-01
Nanostructured tip-shaped biosensors have drawn attention for biomolecule detection as they are promising for highly sensitive and specific detection of a target analyte. Using a nanostructured tip, the sensitivity is increased to identify individual molecules because of the high aspect ratio structure. Various detection methods, such as electrochemistry, fluorescence microcopy, and Raman spectroscopy, have been attempted to enhance the sensitivity and the specificity. Due to the confined path of electrons, electrochemical measurement using a nanotip enables the detection of single molecules. When an electric field is combined with capillary action and fluid flow, target molecules can be effectively concentrated onto a nanotip surface for detection. To enhance the concentration efficacy, a dendritic nanotip rather than a single tip could be used to detect target analytes, such as nanoparticles, cells, and DNA. However, reproducible fabrication with relation to specific detection remains a challenge due to the instability of a manufacturing method, resulting in inconsistent shape. In this paper, nanostructured biosensors are reviewed with our experimental results using dendritic nanotips for sequence specific detection of DNA. By the aid of the Six Sigma approach, the fabrication yield of dendritic nanotips increases from 20.0% to 86.6%. Using the nanotips, DNA is concentrated and detected in a sequence specific way with the detection limit equivalent to 1000 CFU/mL. The pros and cons of a nanotip biosensor are evaluated in conjunction with future prospects. PMID:28025540
Design of Single Stage Axial Turbine with Constant Nozzle Angle Blading for Small Turbojet
NASA Astrophysics Data System (ADS)
Putra Adnan, F.; Hartono, Firman
2018-04-01
In this paper, an aerodynamic design of a single stage gas generator axial turbine for small turbojet engine is explained. As per design requirement, the turbine should be able to deliver power output of 155 kW at 0.8139 kg/s gas mass flow, inlet total temperature of 1200 K and inlet total pressure of 335330 Pa. The design phase consist of several steps, i.e.: determination of velocity triangles in 2D plane, 2D blading design and 3D flow analysis at design point using Computational Fluid Dynamics method. In the determination of velocity triangles, two conditions are applied: zero inlet swirl (i.e. the gas flow enter the turbine at axial direction) and constant nozzle angle design (i.e. the inlet and outlet angle of the nozzle blade are constant from root to tip). The 2D approach in cascade plane is used to specify airfoil type at root, mean and tip of the blade based on inlet and outlet flow conditions. The 3D approach is done by simulating the turbine in full configuration to evaluate the overall performance of the turbine. The observed parameters including axial gap, stagger angle, and tip clearance affect its output power. Based on analysis results, axial gap and stagger angle are positively correlated with output power up to a certain point at which the power decreases. Tip clearance, however, gives inversely correlation with output power.
Akhtar, Kashif; Sugand, Kapil; Sperrin, Matthew; Cobb, Justin; Standfield, Nigel; Gupte, Chinmay
2015-01-01
Virtual-reality (VR) simulation in orthopedic training is still in its infancy, and much of the work has been focused on arthroscopy. We evaluated the construct validity of a new VR trauma simulator for performing dynamic hip screw (DHS) fixation of a trochanteric femoral fracture. 30 volunteers were divided into 3 groups according to the number of postgraduate (PG) years and the amount of clinical experience: novice (1-4 PG years; less than 10 DHS procedures); intermediate (5-12 PG years; 10-100 procedures); expert (> 12 PG years; > 100 procedures). Each participant performed a DHS procedure and objective performance metrics were recorded. These data were analyzed with each performance metric taken as the dependent variable in 3 regression models. There were statistically significant differences in performance between groups for (1) number of attempts at guide-wire insertion, (2) total fluoroscopy time, (3) tip-apex distance, (4) probability of screw cutout, and (5) overall simulator score. The intermediate group performed the procedure most quickly, with the lowest fluoroscopy time, the lowest tip-apex distance, the lowest probability of cutout, and the highest simulator score, which correlated with their frequency of exposure to running the trauma lists for hip fracture surgery. This study demonstrates the construct validity of a haptic VR trauma simulator with surgeons undertaking the procedure most frequently performing best on the simulator. VR simulation may be a means of addressing restrictions on working hours and allows trainees to practice technical tasks without putting patients at risk. The VR DHS simulator evaluated in this study may provide valid assessment of technical skill.
Sakaki, Kelly; Esmaeilsabzali, Hadi; Massah, Shabnam; Prefontaine, Gratien G; Dechev, Nikolai; Burke, Robert D; Park, Edward J
2013-11-01
Single cell electroporation (SCE), via microcapillary, is an effective method for molecular, transmembrane transport used to gain insight on cell processes with minimal preparation. Although possessing great potential, SCE is difficult to execute and the technology spans broad fields within cell biology and engineering. The technical complexities, the focus and expertise demanded during manual operation, and the lack of an automated SCE platform limit the widespread use of this technique, thus the potential of SCE has not been realized. In this study, an automated biomanipulator for SCE is presented. Our system is capable of delivering molecules into the cytoplasm of extremely thin cellular features of adherent cells. The intent of the system is to abstract the technical challenges and exploit the accuracy and repeatability of automated instrumentation, leaving only the focus of the experimental design to the operator. Each sequence of SCE including cell and SCE site localization, tip-membrane contact detection, and SCE has been automated. Positions of low-contrast cells are localized and "SCE sites" for microcapillary tip placement are determined using machine vision. In addition, new milestones within automated cell manipulation have been achieved. The system described herein has the capability of automated SCE of "thin" cell features less than 10 μm in thickness. Finally, SCE events are anticipated using visual feedback, while monitoring fluorescing dye entering the cytoplasm of a cell. The execution is demonstrated by inserting a combination of a fluorescing dye and a reporter gene into NIH/3T3 fibroblast cells.
"One-Size-Does-Not-Fit-All": Teaching MBA Students Different ERP Implementation Strategies
ERIC Educational Resources Information Center
Venkatesh, Viswanath
2008-01-01
This teaching tip discusses an approach to educating MBA students regarding strategies to select, design, and implement enterprise resource planning (ERP) systems. The teaching approach presented here discusses how to teach students about different strategies based success stories from three different organizations, namely Cisco, Tektronix, and…
Tapping mode imaging and measurements with an inverted atomic force microscope.
Chan, Sandra S F; Green, John-Bruce D
2006-07-18
This report demonstrates the successful use of the inverted atomic force microscope (i-AFM) for tapping mode AFM imaging of cantilever-supported samples. i-AFM is a mode of AFM operation in which a sample supported on a tipless cantilever is imaged by one of many tips in a microfabricated tip array. Tapping mode is an intermittent contact mode whereby the cantilever is oscillated at or near its resonance frequency, and the amplitude and/or phase are used to image the sample. In the process of demonstrating that tapping mode images could be obtained in the i-AFM design, it was observed that the amplitude of the cantilever oscillation decreased markedly as the cantilever and tip array were approached. The source of this damping of the cantilever oscillations was identified to be the well-known "squeeze film damping", and the extent of damping was a direct consequence of the relatively shorter tip heights for the tip arrays, as compared to those of commercially available tapping mode cantilevers with integrated tips. The functional form for the distance dependence of the damping coefficient is in excellent agreement with previously published models for squeeze film damping, and the values for the fitting parameters make physical sense. Although the severe damping reduces the cantilever free amplitude substantially, we found that we were still able to access the low-amplitude regime of oscillation necessary for attractive tapping mode imaging of fragile molecules.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, Keith, E-mail: keithjppereira@gmail.com; Carrion, Andres F., E-mail: andres.carrionmonsa@jhsmiami.org; Salsamendi, Jason, E-mail: JSalsamendi@med.miami.edu
Transjugular intrahepatic portosystemic shunt (TIPS) has evolved as an effective intervention for treatment of complications of portal hypertension. The use of polytetrafluoroethylene-covered stents have improved the patency of the shunts and diminished the incidence of TIPS dysfunction. However, TIPS-related refractory hepatic encephalopathy (rHE) poses a significant challenge. Approximately 3–7 % of patients with TIPS develop rHE. Refractory hepatic encephalopathy is defined as a recurrent or persistent encephalopathy despite appropriate medical treatment. Hepatic encephalopathy can be an extremely debilitating complication that profoundly affects quality of life. The approach to management of patients with rHE is complex and typically requires collaboration between differentmore » specialties. Liver transplantation is the ultimate treatment for rHE; however, the ongoing shortage of organ donation markedly limits this treatment option. Alternative therapies such as shunt occlusion or reduction can control symptoms and serve as a ‘bridge’ therapy to liver transplantation. Therefore, interventional radiologists play a key role in the management of these patients by offering a variety of endovascular techniques. The purpose of this review is to highlight some of these endovascular techniques and to develop a therapeutic algorithm that can be applied in clinical practice for the management of rHE.« less
Optical detection of ultrasound using an apertureless near-field scanning optical microscopy system
NASA Astrophysics Data System (ADS)
Ahn, Phillip; Zhang, Zhen; Sun, Cheng; Balogun, Oluwaseyi
2013-01-01
Laser ultrasonics techniques are power approaches for non-contact generation and detection of high frequency ultrasound on a local scale. In these techniques, optical diffraction limits the spatial information that can be accessed from a measurement. In order to improve the lateral spatial resolution, we incorporate an apertureless near-field scanning optical microscope (aNSOM) into laser ultrasonics setup for local detection of laser generated ultrasound. The aNSOM technique relies on the measurement of a weak backscattered near-field light intensity resulting from the oblique illumination of a nanoscale probe-tip positioned close to a sample surface. We enhance the optical near-field intensity by coupling light to surface plasmon polaritons (SPPs) on the shaft of an atomic force microscopy (AFM) cantilever. The SPPs propagate down the AFM shaft, localize at the tip apex, and are backscattered to the far-field when the separation distance between the probe tip and the sample surface is comparable to the probe-tip radius. The backscattered near-field intensity is dynamically modulated when an ultrasonic wave arrives at the sample surface leading to a transient change in the tip-sample separation distance. We present experimental results detailing measurement of broadband and narrowband laser generated ultrasound in solids with frequencies reaching up to 180 MHz range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwarz, Udo; Albers, Boris J.; Liebmann, Marcus
2008-02-27
The authors present the design and first results of a low-temperature, ultrahigh vacuum scanning probe microscope enabling atomic resolution imaging in both scanning tunneling microscopy (STM) and noncontact atomic force microscopy (NC-AFM) modes. A tuning-fork-based sensor provides flexibility in selecting probe tip materials, which can be either metallic or nonmetallic. When choosing a conducting tip and sample, simultaneous STM/NC-AFM data acquisition is possible. Noticeable characteristics that distinguish this setup from similar systems providing simultaneous STM/NC-AFM capabilities are its combination of relative compactness (on-top bath cryostat needs no pit), in situ exchange of tip and sample at low temperatures, short turnaroundmore » times, modest helium consumption, and unrestricted access from dedicated flanges. The latter permits not only the optical surveillance of the tip during approach but also the direct deposition of molecules or atoms on either tip or sample while they remain cold. Atomic corrugations as low as 1 pm could successfully be resolved. In addition, lateral drifts rates of below 15 pm/h allow long-term data acquisition series and the recording of site-specific spectroscopy maps. Results obtained on Cu(111) and graphite illustrate the microscope's performance.« less
Basic features of waste material storage in underground space in relation to geomechanics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konecny, P.
1994-12-31
It is logical to consider utilizing underground cavities for waste material disposal because, during mining, great volumes of rock materials are extracted, and underground hollow areas and communicating workings are created that can, in general, be utilized for waste disposal. Additionally, in many cases, underground waste disposal favorably supports mining process technology (for instance, application of power plant fly ash and preparation plant tailings as hardened backfill). However, it is necessary to give particular attention to the preparation, operation, and isolation of underground tip areas; errors and, in extreme cases, emergencies in underground tips are generally more difficult to dealmore » with than those in surface tips. A tip place constructed underground becomes part of the rock massif; therefore, all natural laws that rule the rock massif must be respected. Of course, such an approach requires knowledge of processes and natural regularities that will occur in rock strata where tip places have been constructed. Such knowledge is gained through familiarity with contemporary geomechanical science. The paper discusses basic geomechanical principles of underground waste disposal; geomechanical aspects of rock massif evaluation in view of waste material storage in mine workings; and plans for an experimental project for waste disposal in the Dul Ostrava underground mine.« less
Niu, Gang; Capellini, Giovanni; Schubert, Markus Andreas; Niermann, Tore; Zaumseil, Peter; Katzer, Jens; Krause, Hans-Michael; Skibitzki, Oliver; Lehmann, Michael; Xie, Ya-Hong; von Känel, Hans; Schroeder, Thomas
2016-03-04
The integration of dislocation-free Ge nano-islands was realized via selective molecular beam epitaxy on Si nano-tip patterned substrates. The Si-tip wafers feature a rectangular array of nanometer sized Si tips with (001) facet exposed among a SiO2 matrix. These wafers were fabricated by complementary metal-oxide-semiconductor (CMOS) compatible nanotechnology. Calculations based on nucleation theory predict that the selective growth occurs close to thermodynamic equilibrium, where condensation of Ge adatoms on SiO2 is disfavored due to the extremely short re-evaporation time and diffusion length. The growth selectivity is ensured by the desorption-limited growth regime leading to the observed pattern independence, i.e. the absence of loading effect commonly encountered in chemical vapor deposition. The growth condition of high temperature and low deposition rate is responsible for the observed high crystalline quality of the Ge islands which is also associated with negligible Si-Ge intermixing owing to geometric hindrance by the Si nano-tip approach. Single island as well as area-averaged characterization methods demonstrate that Ge islands are dislocation-free and heteroepitaxial strain is fully relaxed. Such well-ordered high quality Ge islands present a step towards the achievement of materials suitable for optical applications.
Niu, Gang; Capellini, Giovanni; Schubert, Markus Andreas; Niermann, Tore; Zaumseil, Peter; Katzer, Jens; Krause, Hans-Michael; Skibitzki, Oliver; Lehmann, Michael; Xie, Ya-Hong; von Känel, Hans; Schroeder, Thomas
2016-01-01
The integration of dislocation-free Ge nano-islands was realized via selective molecular beam epitaxy on Si nano-tip patterned substrates. The Si-tip wafers feature a rectangular array of nanometer sized Si tips with (001) facet exposed among a SiO2 matrix. These wafers were fabricated by complementary metal-oxide-semiconductor (CMOS) compatible nanotechnology. Calculations based on nucleation theory predict that the selective growth occurs close to thermodynamic equilibrium, where condensation of Ge adatoms on SiO2 is disfavored due to the extremely short re-evaporation time and diffusion length. The growth selectivity is ensured by the desorption-limited growth regime leading to the observed pattern independence, i.e. the absence of loading effect commonly encountered in chemical vapor deposition. The growth condition of high temperature and low deposition rate is responsible for the observed high crystalline quality of the Ge islands which is also associated with negligible Si-Ge intermixing owing to geometric hindrance by the Si nano-tip approach. Single island as well as area-averaged characterization methods demonstrate that Ge islands are dislocation-free and heteroepitaxial strain is fully relaxed. Such well-ordered high quality Ge islands present a step towards the achievement of materials suitable for optical applications. PMID:26940260
Meng, Fengqun; Cao, Rui; Yang, Dongmei; Niklas, Karl J; Sun, Shucun
2014-01-01
Species in high-rainfall regions have two major alternative approaches to quickly drain off water, i.e., increasing leaf inclination angles relative to the horizontal plane, or developing long leaf drip tips. We hypothesized that shade-adapted species will have more pronounced leaf drip tips but not greater inclination angles (which can reduce the ability to intercept light) compared to sun-adapted species and that length of leaf drip tips will be negatively correlated with photosynthetic capacity [characterized by light-saturated net photosynthetic rates (Amax), associated light compensation points (LCP), and light saturation points (LSP)]. We tested this hypothesis by measuring morphological and physiological traits that are associated with light-interception and water shedding for seven shade-adapted shrub species, ten sun-adapted understory shrub species, and 15 sun-adapted tree species in a subtropical Chinese rainforest, where mean annual precipitation is around 1,600 mm. Shade-adapted understory species had lower LMA, Amax, LSP, and LCP compared to understory or canopy sun-adapted species; their leaf and twig inclination angles were significantly smaller and leaf drip tips were significantly longer than those in sun-adapted species. This suggests that shade-adapted understory species tend to develop pronounced leaf drip tips but not large leaf inclination angles to shed water. The length of leaf drip tips was negatively correlated with leaf inclination angles and photosynthetic capacity. These relationships were consistent between ordinary regression and phylogenetic generalized least squares analyses. Our study illustrates the trade-offs between light interception and leaf water shedding and indicates that length of leaf drip tips can be used as an indicator of adaptation to shady conditions and overall photosynthetic performance of shrub species in subtropical rainforests.
Cut-cell method based large-eddy simulation of tip-leakage flow
NASA Astrophysics Data System (ADS)
Pogorelov, Alexej; Meinke, Matthias; Schröder, Wolfgang
2015-07-01
The turbulent low Mach number flow through an axial fan at a Reynolds number of 9.36 × 105 based on the outer casing diameter is investigated by large-eddy simulation. A finite-volume flow solver in an unstructured hierarchical Cartesian setup for the compressible Navier-Stokes equations is used. To account for sharp edges, a fully conservative cut-cell approach is applied. A newly developed rotational periodic boundary condition for Cartesian meshes is introduced such that the simulations are performed just for a 72° segment, i.e., the flow field over one out of five axial blades is resolved. The focus of this numerical analysis is on the development of the vortical flow structures in the tip-gap region. A detailed grid convergence study is performed on four computational grids with 50 × 106, 250 × 106, 1 × 109, and 1.6 × 109 cells. Results of the instantaneous and the mean fan flow field are thoroughly analyzed based on the solution with 1 × 109 cells. High levels of turbulent kinetic energy and pressure fluctuations are generated by a tip-gap vortex upstream of the blade, the separating vortices inside the tip gap, and a counter-rotating vortex on the outer casing wall. An intermittent interaction of the turbulent wake, generated by the tip-gap vortex, with the downstream blade, leads to a cyclic transition with high pressure fluctuations on the suction side of the blade and a decay of the tip-gap vortex. The disturbance of the tip-gap vortex results in an unsteady behavior of the turbulent wake causing the intermittent interaction. For this interaction and the cyclic transition, two dominant frequencies are identified which perfectly match with the characteristic frequencies in the experimental sound power level and therefore explain their physical origin.
Shivalli, Siddharudha; Srivastava, Ratan Kumar; Singh, Gyan Prakash
2015-01-01
Background Behavior Change Communications (BCC) play a decisive role in modifying socio-cultural norms affecting the perception and nutritional practices during pregnancy. Objective To examine the effectiveness of ‘Trials of Improved Practices’ (TIPs) on dietary and iron-folate intake during pregnancy. Design Community based quasi experimental study with a control group Setting Four villages of Chiraigaon Community Development Block of Varanasi, India from May 2010 and recruited from August 2010. End line assessment, after 12 weeks of intervention, was completed in April 2011. Participants Pregnant women in 13–28 weeks of gestation Intervention TIPs was implemented in addition to ongoing essential obstetric care services in two villages through 3 home (assessment, negotiation and evaluation) visits and only assessment and evaluation visits in the other two control villages. Interpersonal communication, endorsing the active participation of family members and home based reminder materials were the TIPs based strategies. The effect of TIPs was assessed by comparing key outcome variables at baseline and after 12 weeks of intervention. Outcome Measures Hemoglobin%, anemia prevalence, weight gain, compliance for iron-folate supplementation and dietary intake of calorie, protein, calcium and iron. Results A total of 86 participants completed the study. At the end, mean hemoglobin levels were 11.5±1.24 g/dl and 10.37±1.38 g/dl in the TIPs and control groups, respectively. The prevalence of anemia reduced by half in TIPs group and increased by 2.4% in the control group. Weight gain (grams/week) was significantly (p<0.01) higher in TIPs group (326.9±91.8 vs. 244.6±97.4). More than 85% of the PW in TIPs group were compliant for Iron-folate and only 38% were compliant among controls. The mean intake of protein increased by 1.78gm in intervention group and decreased by 1.81 gm in controls (p<0.05). More than two thirds of PW in TIPs group were taking one extra meal and only one third of controls were doing the same. Conclusion TIPs found to be an effective approach to improve the nutritional status of pregnant women in the study area. TIPs strategy could be further explored on larger sample representing different socio-cultural and geographical areas. Trial Registration Clinical Trial Registry of India CTRI/2015/02/005517 PMID:26367775
Torres, Luis G.; Kuntz, Alan; Gilbert, Hunter B.; Swaney, Philip J.; Hendrick, Richard J.; Webster, Robert J.; Alterovitz, Ron
2015-01-01
Concentric tube robots are thin, tentacle-like devices that can move along curved paths and can potentially enable new, less invasive surgical procedures. Safe and effective operation of this type of robot requires that the robot’s shaft avoid sensitive anatomical structures (e.g., critical vessels and organs) while the surgeon teleoperates the robot’s tip. However, the robot’s unintuitive kinematics makes it difficult for a human user to manually ensure obstacle avoidance along the entire tentacle-like shape of the robot’s shaft. We present a motion planning approach for concentric tube robot teleoperation that enables the robot to interactively maneuver its tip to points selected by a user while automatically avoiding obstacles along its shaft. We achieve automatic collision avoidance by precomputing a roadmap of collision-free robot configurations based on a description of the anatomical obstacles, which are attainable via volumetric medical imaging. We also mitigate the effects of kinematic modeling error in reaching the goal positions by adjusting motions based on robot tip position sensing. We evaluate our motion planner on a teleoperated concentric tube robot and demonstrate its obstacle avoidance and accuracy in environments with tubular obstacles. PMID:26413381
Torres, Luis G; Kuntz, Alan; Gilbert, Hunter B; Swaney, Philip J; Hendrick, Richard J; Webster, Robert J; Alterovitz, Ron
2015-05-01
Concentric tube robots are thin, tentacle-like devices that can move along curved paths and can potentially enable new, less invasive surgical procedures. Safe and effective operation of this type of robot requires that the robot's shaft avoid sensitive anatomical structures (e.g., critical vessels and organs) while the surgeon teleoperates the robot's tip. However, the robot's unintuitive kinematics makes it difficult for a human user to manually ensure obstacle avoidance along the entire tentacle-like shape of the robot's shaft. We present a motion planning approach for concentric tube robot teleoperation that enables the robot to interactively maneuver its tip to points selected by a user while automatically avoiding obstacles along its shaft. We achieve automatic collision avoidance by precomputing a roadmap of collision-free robot configurations based on a description of the anatomical obstacles, which are attainable via volumetric medical imaging. We also mitigate the effects of kinematic modeling error in reaching the goal positions by adjusting motions based on robot tip position sensing. We evaluate our motion planner on a teleoperated concentric tube robot and demonstrate its obstacle avoidance and accuracy in environments with tubular obstacles.
Compact variable-temperature scanning force microscope.
Chuang, Tien-Ming; de Lozanne, Alex
2007-05-01
A compact design for a cryogenic variable-temperature scanning force microscope using a fiber-optic interferometer to measure cantilever deflection is presented. The tip-sample coarse approach and the lateral tip positioning are performed by piezoelectric positioners in situ. The microscope has been operated at temperatures between 6 and 300 K. It is designed to fit into an 8 T superconducting magnet with the field applied in the out-of-plane direction. The results of scanning in various modes are demonstrated, showing contrast based on magnetic field gradients or surface potentials.
Highly Productive Tools For Turning And Milling
NASA Astrophysics Data System (ADS)
Vasilko, Karol
2015-12-01
Beside cutting speed, shift is another important parameter of machining. Its considerable influence is shown mainly in the workpiece machined surface microgeometry. In practice, mainly its combination with the radius of cutting tool tip rounding is used. Options to further increase machining productivity and machined surface quality are hidden in this approach. The paper presents variations of the design of productive cutting tools for lathe work and milling on the base of the use of the laws of the relationship among the highest reached uneveness of machined surface, tool tip radius and shift.
Numerical investigation of tip clearance cavitation in Kaplan runners
NASA Astrophysics Data System (ADS)
Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.
2016-11-01
There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.
Lakhoo, Janesh; Bui, James T; Lokken, R Peter; Ray, Charles E; Gaba, Ron C
2016-07-01
To assess the efficacy of transjugular intrahepatic portosystemic shunt (TIPS) creation with or without variceal coil and/or plug embolization in decompressing or occluding gastric varices (GVs). In this retrospective study, 78 patients with GV bleeding who underwent TIPS creation with or without embolotherapy with metallic coils and/or plugs from 1999 to 2014 were identified. Individuals who had a bare-metal TIPS and/or lacked post-TIPS imaging or endoscopic follow-up were excluded. The final cohort included 26 patients (16 men; median age, 54 y; median Model for End-stage Liver Disease score, 16). Variceal types, supplying vessels, and postprocedure GV patency on cross-sectional imaging or endoscopy were assessed. The primary study outcome measure was GV patency rate as a surrogate for efficacy of TIPS creation with or without embolization. GVs included gastroesophageal varix types 1 (n = 10) and 2 (n = 2), isolated GV types 1 (n = 4) and 2 (n = 2), and unspecified (n = 8). TIPS creation resulted in a median final portosystemic pressure gradient of 7 mm Hg. Multiple GV-supplying vessels (left/posterior/short gastric veins) were present in 65% of patients (n = 17). Embolization was performed in 69% (n = 18). Thirteen, four, and nine patients had imaging, endoscopic, or both imaging/endoscopic follow-up. GV patency rate was 65% (n = 17; 61%/75% with/without embolization) at a median of 128.5 days (range, 1-1,295 d) after TIPS creation. Incidence of recurrent bleeding was 27% (n = 7), and the 90-day mortality rate was 15% (n = 4). In this study, most GVs showed persistent patency despite TIPS decompression and variceal embolization, and the incidence of recurrent bleeding was high. The findings suggest suboptimal efficacy for GVs, and indicate a need for study of alternative or adjunctive approaches to GV treatment, such as chemical obliteration. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Huanbin; Xue, Guobiao; Wu, Jiake
Multi-component active materials are widely used for organic electronic devices, with every component contributing complementary and synergistic optoelectronic functions. Mixing these components generally leads to lowered crystallinity and weakened charge transport. Therefore, preparing the active materials without substantially disrupting the crystalline lattice is highly desired. In this paper, we show that crystallization of TIPS-pentacene from solutions in the presence of fluorescent nanofibers of a perylene bisimide derivative (PBI) leads to formation of composites with nanofiber guest incorporated in the crystal host. In spite of the binary composite structure, the TIPS-pentacene maintains the single-crystalline nature. As a result, the incorporation ofmore » the PBI guest introduces additional fluorescence function but does not significantly reduce the charge transport property of the TIPS-pentacene host, exhibiting field-effect mobility as high as 3.34 cm 2 V -1 s -1 even though 26.4% of the channel area is taken over by the guest. Finally, as such, this work provides a facile approach toward high-performance multifunctional organic electronic materials.« less
Atomistic minimal model for estimating profile of electrodeposited nanopatterns
NASA Astrophysics Data System (ADS)
Asgharpour Hassankiadeh, Somayeh; Sadeghi, Ali
2018-06-01
We develop a computationally efficient and methodologically simple approach to realize molecular dynamics simulations of electrodeposition. Our minimal model takes into account the nontrivial electric field due a sharp electrode tip to perform simulations of the controllable coating of a thin layer on a surface with an atomic precision. On the atomic scale a highly site-selective electrodeposition of ions and charged particles by means of the sharp tip of a scanning probe microscope is possible. A better understanding of the microscopic process, obtained mainly from atomistic simulations, helps us to enhance the quality of this nanopatterning technique and to make it applicable in fabrication of nanowires and nanocontacts. In the limit of screened inter-particle interactions, it is feasible to run very fast simulations of the electrodeposition process within the framework of the proposed model and thus to investigate how the shape of the overlayer depends on the tip-sample geometry and dielectric properties, electrolyte viscosity, etc. Our calculation results reveal that the sharpness of the profile of a nano-scale deposited overlayer is dictated by the normal-to-sample surface component of the electric field underneath the tip.
The sinusoidal probe: a new approach to improve electrode longevity
Sohal, Harbaljit S.; Jackson, Andrew; Jackson, Richard; Clowry, Gavin J.; Vassilevski, Konstantin; O’Neill, Anthony; Baker, Stuart N.
2014-01-01
Micromotion between the brain and implanted electrodes is a major contributor to the failure of invasive brain–machine interfaces. Movements of the electrode tip cause recording instabilities while spike amplitudes decline over the weeks/months post-implantation due to glial cell activation caused by sustained mechanical trauma. We have designed a sinusoidal probe in order to reduce movement of the recording tip relative to the surrounding neural tissue. The probe was microfabricated from flexible materials and incorporated a sinusoidal shaft to minimize tethering forces and a 3D spheroid tip to anchor the recording site within the brain. Compared to standard microwire electrodes, the signal-to-noise ratio and local field potential power of sinusoidal probe recordings from rabbits was more stable across recording periods up to 678 days. Histological quantification of microglia and astrocytes showed reduced neuronal tissue damage especially for the tip region between 6 and 24 months post-implantation. We suggest that the micromotion-reducing measures incorporated into our design, at least partially, decreased the magnitude of gliosis, resulting in enhanced longevity of recording. PMID:24808859
Li, Huanbin; Xue, Guobiao; Wu, Jiake; ...
2017-08-18
Multi-component active materials are widely used for organic electronic devices, with every component contributing complementary and synergistic optoelectronic functions. Mixing these components generally leads to lowered crystallinity and weakened charge transport. Therefore, preparing the active materials without substantially disrupting the crystalline lattice is highly desired. In this paper, we show that crystallization of TIPS-pentacene from solutions in the presence of fluorescent nanofibers of a perylene bisimide derivative (PBI) leads to formation of composites with nanofiber guest incorporated in the crystal host. In spite of the binary composite structure, the TIPS-pentacene maintains the single-crystalline nature. As a result, the incorporation ofmore » the PBI guest introduces additional fluorescence function but does not significantly reduce the charge transport property of the TIPS-pentacene host, exhibiting field-effect mobility as high as 3.34 cm 2 V -1 s -1 even though 26.4% of the channel area is taken over by the guest. Finally, as such, this work provides a facile approach toward high-performance multifunctional organic electronic materials.« less
The performance of the MROI fast tip-tilt correction system
NASA Astrophysics Data System (ADS)
Young, John; Buscher, David; Fisher, Martin; Haniff, Christopher; Rea, Alexander; Seneta, Eugene; Sun, Xiaowei; Wilson, Donald; Farris, Allen; Olivares, Andres
2014-07-01
The fast tip-tilt (FTT) correction system for the Magdalena Ridge Observatory Interferometer (MROI) is being developed by the University of Cambridge. The design incorporates an EMCCD camera protected by a thermal enclosure, optical mounts with passive thermal compensation, and control software running under Xenomai real-time Linux. The complete FTT system is now undergoing laboratory testing prior to being installed on the first MROI unit telescope in the fall of 2014. We are following a twin-track approach to testing the closed-loop performance: tracking tip-tilt perturbations introduced by an actuated flat mirror in the laboratory, and undertaking end-to-end simulations that incorporate realistic higher-order atmospheric perturbations. We report test results that demonstrate (a) the high stability of the entire opto-mechanical system, realized with a completely passive design; and (b) the fast tip-tilt correction performance and limiting sensitivity. Our preliminary results in both areas are close to those needed to realise the ambitious stability and sensitivity goals of the MROI which aims to match the performance of current natural guide star adaptive optics systems.
A novel drill design for photoacoustic guided surgeries
NASA Astrophysics Data System (ADS)
Shubert, Joshua; Lediju Bell, Muyinatu A.
2018-02-01
Fluoroscopy is currently the standard approach for image guidance of surgical drilling procedures. In addition to the harmful radiation dose to the patient and surgeon, fluoroscopy fails to visualize critical structures such as blood vessels and nerves within the drill path. Photoacoustic imaging is a well-suited imaging method to visualize these structures and it does not require harmful ionizing radiation. However, there is currently no clinical system available to deliver light to occluded drill bit tips. To address this challenge, a prototype drill was designed, built, and tested using an internal light delivery system that allows laser energy to be transferred from a stationary laser source to the tip of a spinning drill bit. Photoacoustic images were successfully obtained with the drill bit submerged in water and with the drill tip inserted into a thoracic vertebra from a human cadaver.
NASA Technical Reports Server (NTRS)
Kazin, S. B.
1973-01-01
Acoustic tests were conducted on a high tip speed (1550 ft/sec, 472.44 m/sec) single stage fan with varying amounts of wall acoustic treatment and with circumferential slots over the rotor blade tips. The slots were also tested with acoustic treatment placed behind the slots. The wall treatment results show that the inlet treatment is more effective at high fan speeds and aft duct treatment is more effective at low fan speeds. Maximum PNL's on a 200-foot (60.96 m) sideline show the untreated slots to have increased the rear radiated noise at approach. However, when the treatment was added to the slots inlet radiated noise was decreased, resulting in little change relative to the solid casing on an EPNL basis.
NASA Astrophysics Data System (ADS)
Canzian, Blaise; Barentine, J.; Arendt, J.; Bader, S.; Danyo, G.; Heller, C.
2012-09-01
L-3 Integrated Optical Systems (IOS) Division has been selected by the National Solar Observatory (NSO) to design and produce the Top End Optical Assembly (TEOA) for the 4-meter Advanced Technology Solar Telescope (ATST) to operate at Haleakal', Maui. ATST will perform to a very high optical performance level in a difficult thermal environment. The TEOA, containing the 0.65-meter silicon carbide secondary mirror and support, mirror thermal management system, mirror positioning and fast tip-tilt system, field stop with thermally managed heat dump, thermally managed Lyot stop, safety interlock and control system, and support frame, operates in the "hot spot" at the prime focus of the ATST and so presents special challenges. In this paper, we describe progress in the L-3 technical approach to meeting these challenges, including silicon carbide off-axis mirror design, fabrication, and high accuracy figuring and polishing all within L-3; mirror support design; the design for stray light control; subsystems for opto-mechanical positioning and high accuracy absolute mirror orientation sensing; Lyot stop design; and thermal management of all design elements to remain close to ambient temperature despite the imposed solar irradiance load.
Servat, Juan J; Elia, Maxwell Dominic; Gong, Dan; Manes, R Peter; Black, Evan H; Levin, Flora
2014-12-01
To assess the feasibility of routine use of electromagnetic image guidance systems in orbital decompression. Six consecutive patients underwent stereotactic-guided three wall orbital decompression using the novel Fusion ENT Navigation System (Medtronic), a portable and expandable electromagnetic guidance system with multi-instrument tracking capabilities. The system consists of the Medtronic LandmarX System software-enabled computer station, signal generator, field-generating magnet, head-mounted marker coil, and surgical tracking instruments. In preparation for use of the LandmarX/Fusion protocol, all patients underwent preoperative non-contrast CT scan from the superior aspect of the frontal sinuses to the inferior aspect of the maxillary sinuses that includes the nasal tip. The Fusion ENT Navigation System (Medtronic™) was used in 6 patients undergoing maximal 3-wall orbital decompression for Graves' orbitopthy after a minimum of six months of disease inactivity. Preoperative Hertel exophthalmometry measured more than 27 mm in all patients. The navigation system proved to be no more difficult technically than the traditional orbital decompression approach. Electromagnetic image guidance is a stereotactic surgical navigation system that provides additional intraoperative flexibility in orbital surgery. Electromagnetic image-guidance offers the ability to perform more aggressive orbital decompressions with reduced risk.
ASME V\\&V challenge problem: Surrogate-based V&V
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beghini, Lauren L.; Hough, Patricia D.
2015-12-18
The process of verification and validation can be resource intensive. From the computational model perspective, the resource demand typically arises from long simulation run times on multiple cores coupled with the need to characterize and propagate uncertainties. In addition, predictive computations performed for safety and reliability analyses have similar resource requirements. For this reason, there is a tradeoff between the time required to complete the requisite studies and the fidelity or accuracy of the results that can be obtained. At a high level, our approach is cast within a validation hierarchy that provides a framework in which we perform sensitivitymore » analysis, model calibration, model validation, and prediction. The evidence gathered as part of these activities is mapped into the Predictive Capability Maturity Model to assess credibility of the model used for the reliability predictions. With regard to specific technical aspects of our analysis, we employ surrogate-based methods, primarily based on polynomial chaos expansions and Gaussian processes, for model calibration, sensitivity analysis, and uncertainty quantification in order to reduce the number of simulations that must be done. The goal is to tip the tradeoff balance to improving accuracy without increasing the computational demands.« less
Advances in laser technology and fibre-optic delivery systems in lithotripsy.
Fried, Nathaniel M; Irby, Pierce B
2018-06-08
The flashlamp-pumped, solid-state holmium:yttrium-aluminium-garnet (YAG) laser has been the laser of choice for use in ureteroscopic lithotripsy for the past 20 years. However, although the holmium laser works well on all stone compositions and is cost-effective, this technology still has several fundamental limitations. Newer laser technologies, including the frequency-doubled, double-pulse YAG (FREDDY), erbium:YAG, femtosecond, and thulium fibre lasers, have all been explored as potential alternatives to the holmium:YAG laser for lithotripsy. Each of these laser technologies is associated with technical advantages and disadvantages, and the search continues for the next generation of laser lithotripsy systems that can provide rapid, safe, and efficient stone ablation. New fibre-optic approaches for safer and more efficient delivery of the laser energy inside the urinary tract include the use of smaller-core fibres and fibres that are tapered, spherical, detachable or hollow steel, or have muzzle brake distal fibre-optic tips. These specialty fibres might provide advantages, including improved flexibility for maximal ureteroscope deflection, reduced cross section for increased saline irrigation rates through the working channel of the ureteroscope, reduced stone retropulsion for improved stone ablation efficiency, and reduced fibre degradation and burnback for longer fibre life.
Tip-over prevention through heuristic reactive behaviors for unmanned ground vehicles
NASA Astrophysics Data System (ADS)
Talke, Kurt; Kelley, Leah; Longhini, Patrick; Catron, Garret
2014-06-01
Skid-steer teleoperated robots are commonly used by military and civilian crews to perform high-risk, dangerous and critical tasks such as bomb disposal. Their missions are often performed in unstructured environments with irregular terrain, such as inside collapsed buildings or on rough terrain covered with a variety of media, such as sand, brush, mud, rocks and debris. During such missions, it is often impractical if not impossible to send another robot or a human operator to right a toppled robot. As a consequence, a robot tip-over event usually results in mission failure. To make matters more complicated, such robots are often equipped with heavy payloads that raise their centers of mass and hence increase their instability. Should the robot be equipped with a manipulator arm or flippers, it may have a way to self-right. The majority of manipulator arms are not designed for and are likely to be damaged during self-righting procedures, however, which typically have a low success rate. Furthermore, those robots not equipped with manipulator arms or flippers have no self-righting capabilities. Additionally, due to the on-board camera frame of reference, the video feed may cause the robot to appear to be on at level ground, when it actually may be on a slope nearing tip-over. Finally, robot operators are often so focused on the mission at hand they are oblivious to their surroundings, similar to a kid playing a video game. While this may not be an issue in the living room, it is not a good scenario to experience on the battlefield. Our research seeks to remove tip-over monitoring from the already large list of tasks an operator must perform. An autonomous tip-over prevention behavior for a mobile robot with a static payload has been developed, implemented and experimentally validated on two different teleoperated robotic platforms. Suitable for use with both teleoperated and autonomous robots, the prevention behavior uses the force-angle stability measure, previously experimentally validated, to predict the likelihood of robot tip-over and trigger prevention behaviors. A unique heuristic approach to tip-over avoidance was investigated, wherein a set of evasive maneuvers that an expert teleoperator might take are activated when the tip-over-likelihood estimate passes a critical threshold. This control approach was validated on an iRobot Packbot as well as on a Segway RMP 440. The heuristic laws demonstrated the advantage of alerting operators to a tip-over scenario and gave them more time to correct the situation, as well as the ability to automatically initiate recovery on the y". This research shows promise in preventing dangerous scenarios that could damage a robot and/or compromise its mission, thus saving lives. It further provides a good foundation for follow-on development involving the expansion and integration of the prevention-control algorithms, to include movable payloads, environment manipulation, 2D or 3D look-ahead laser sensing and mapping, and adaptive path planning.
Cugat, Ramón; Alentorn-Geli, Eduard; Cuscó, Xavier; Navarro, Jordi; Steinbacher, Gilbert; Álvarez-Díaz, Pedro; Seijas, Roberto; Barastegui, David; García-Balletbó, Montse
2018-02-01
Posterior cruciate ligament reconstruction using the transtibial technique provides successful clinical outcomes. However, a bone-patellar tendon-bone (BTB) autograft with the transtibial technique has not been used by some surgeons because of concerns with graft passage from the tibial to the femoral tunnels (sharp turn) that can damage graft fibers. In the present surgical technique, an arthroscopic, transtibial, single-bundle technique for posterior cruciate ligament reconstruction using the BTB autograft with an easy and effective technical tip to facilitate graft passage is presented. Once the BTB is harvested, the femoral bone block is divided into 2 equal-sized blocks providing an articulated structure while preserving the tendon component. This facilitates the passage of the BTB tendon once it is entered in the posterior tibia and the graft has to make a sharp turn to reach the femoral tunnel. This easy and effective technique tip may avoid graft damage during the sharp turn, while maintaining all the advantages of a BTB autograft (bone-to-bone healing, own tissue with fast incorporation, and strong fixation and stability).
Development of the fast steering secondary mirror assembly of GMT
NASA Astrophysics Data System (ADS)
Lee, Sungho; Cho, Myung K.; Park, Chan; Han, Jeong-Yeol; Jeong, Ueejeong; Yoon, Yang-noh; Song, Je Heon; Park, Byeong-Gon; Dribusch, Christoph; Park, Won Hyun; Jun, Youra; Yang, Ho-Soon; Moon, Il-Kwon; Oh, Chang Jin; Kim, Ho-Sang; Lee, Kyoung-Don; Bernier, Robert; Alongi, Chris; Rakich, Andrew; Gardner, Paul; Dettmann, Lee; Rosenthal, Wylie
2016-07-01
The Giant Magellan Telescope (GMT) will be featured with two Gregorian secondary mirrors, an adaptive secondary mirror (ASM) and a fast-steering secondary mirror (FSM). The FSM has an effective diameter of 3.2 m and built as seven 1.1 m diameter circular segments, which are conjugated 1:1 to the seven 8.4m segments of the primary. Each FSM segment contains a tip-tilt capability for fine co-alignment of the telescope sub-apertures and fast guiding to attenuate telescope wind shake and mount control jitter. This tip-tilt capability thus enhances performance of the telescope in the seeing limited observation mode. As the first stage of the FSM development, Phase 0 study was conducted to develop a program plan detailing the design and manufacturing process for the seven FSM segments. The FSM development plan has been matured through an internal review by the GMTO-KASI team in May 2016 and fully assessed by an external review in June 2016. In this paper, we present the technical aspects of the FSM development plan.
Guidelines for preparing software user documentation
NASA Technical Reports Server (NTRS)
Miller, Diane F.
1987-01-01
Clear, easy-to-use software user's manuals make strong demands on special technical communication techniques. Principles and guidelines are given for analyzing the audience and dealing with wide-ranging backgrounds of potential users. Types of information to be included in a complete manual are suggested, with a technique for creating a user-oriented rather than process-oriented organization. Accuracy verification is emphasized. Simple tips are gievn for formatting for quick comprehension and reference, for deciding on packaging, for creating helpful illustrations and examples, and for setting up clear and consistent conventions. Simple guidelines are offered for writing clearly and concisely and for editing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
E.N. Stepanov; I.I. Mel'nikov; V.P. Gridasov
In active production at OAO Magnitogorskii Metallurgicheskii Kombinat (MMK), samples of melt materials were taken during shutdown and during planned repairs at furnaces 1 and 8. In particular, coke was taken from the tuyere zone at different distances from the tuyere tip. The mass of the point samples was 2-15 kg, depending on the sampling zone. The material extracted from each zone underwent magnetic separation and screening by size class. The resulting coke sample was averaged out and divided into parts: one for determining the granulometric composition and mechanical strength; and the other for technical analysis and determination of themore » physicochemical properties of the coke.« less
Ehud, Atoun; Ehud, Rath; Alexander, Van Tongel; Ali, Narvani; Giusseppe, Sforza; Ofer, Levy
2012-07-01
A new technical tip for the improvement of the arthroscopic treatment of symptomatic calcifying tendinitis is described. Arthroscopic excision of calcifying tendonitis may result with multiple minute calcific debris in the subacromial bursa, causing severe post operative pain due to chemical irritation of the bursa. We suggest the use of a bladeless shaver barrel as a "Hoover" (vacuum cleaner) for arthroscopic clearance of these miniature calcific debris from the subacromial space after resection of the major deposits. The use of this technique resulted in good clinical outcome with improved post operative pain.
Robitschek, Jon; Dresner, Harley; Hilger, Peter
2017-12-01
Photographic nasal analysis constitutes a critical step along the path toward accurate diagnosis and precise surgical planning in rhinoplasty. The learned process by which one assesses photographs, analyzes relevant anatomical landmarks, and generates a global view of the nasal aesthetic is less widely described. To discern the common pitfalls in performing photographic nasal analysis and to quantify the utility of a systematic approach model in teaching photographic nasal analysis to otolaryngology residents. This prospective observational study included 20 participants from a university-based otolaryngology residency program. The control and intervention groups underwent baseline graded assessment of 3 patients. The intervention group received instruction on a systematic approach model for nasal analysis, and both groups underwent postintervention testing at 10 weeks. Data were collected from October 1, 2015, through June 1, 2016. A 10-minute, 11-slide presentation provided instruction on a systematic approach to nasal analysis to the intervention group. Graded photographic nasal analysis using a binary 18-point system. The 20 otolaryngology residents (15 men and 5 women; age range, 24-34 years) were adept at mentioning dorsal deviation and dorsal profile with focused descriptions of tip angle and contour. Areas commonly omitted by residents included verification of the Frankfort plane, position of the lower lateral crura, radix position, and ratio of the ala to tip lobule. The intervention group demonstrated immediate improvement after instruction on the teaching model, with the mean (SD) postintervention test score doubling compared with their baseline performance (7.5 [2.7] vs 10.3 [2.5]; P < .001). At 10 weeks after the intervention, the mean comparative improvement in overall graded nasal analysis was 17% (95% CI, 10%-23%; P < .001). Otolaryngology residents demonstrated proficiency at incorporating nasal deviation, tip angle, and dorsal profile contour into their nasal analysis. They often omitted verification of the Frankfort plane, position of lower lateral crura, radix depth, and ala-to-tip lobule ratio. Findings with this novel 10-minute teaching model should be validated at other teaching institutions, and the instruction model should be further enhanced to teach more sophisticated analysis to residents as they proceed through training. NA.
Tam, Yuk Him; Pang, Kristine Kit Yi; Wong, Yuen Shan; Tsui, Siu Yan; Wong, Hei Yi; Mou, Jennifer Wai Cheung; Chan, Kin Wai; Lee, Kim Hung
2016-11-01
To investigate and compare the outcomes after tubularized incised plate (TIP) urethroplasty in mid-shaft and proximal hypospadias using a standard and a modified technique. We conducted a retrospective study in 104 consecutive children who underwent mid-shaft or proximal TIP repairs from Jan 2007 to Sept 2015. Patients in Cohort One had dorsal dartos (DD) neourethral coverage while patients in Cohort Two had either de-epithelialized split preputial (DESP) or tunica vaginalis (TV) flap coverage. TV flap was used only when DESP flap was not sufficient to cover the neourethra. There were 52 patients each in Cohort One (DD, n = 52) and Cohort Two (DESP, n = 38; TV, n = 14) with no difference in ratio of mid-shaft/proximal between the two cohorts. At a median follow-up of 28 months, 36 patients (34.6 %) developed 47 complications including fistula (n = 19; 18.3 %) and neourethral dehiscence (n = 4; 3.8 %). Cohort One patients had significantly more fistula (28.8 vs 7.7 %; p = 0.005) and neourethral dehiscence (7.7 vs 0 %; p = 0.04) than Cohort Two. There was no difference between the two cohorts in the complication rates of meatal stenosis, recurrent ventral curvature and neourethral stricture. Both DESP and TV flap appear to be superior to DD in preventing fistula and neourethral dehiscence in non-distal TIP repairs.
Wavefront sensing and adaptive control in phased array of fiber collimators
NASA Astrophysics Data System (ADS)
Lachinova, Svetlana L.; Vorontsov, Mikhail A.
2011-03-01
A new wavefront control approach for mitigation of atmospheric turbulence-induced wavefront phase aberrations in coherent fiber-array-based laser beam projection systems is introduced and analyzed. This approach is based on integration of wavefront sensing capabilities directly into the fiber-array transmitter aperture. In the coherent fiber array considered, we assume that each fiber collimator (subaperture) of the array is capable of precompensation of local (onsubaperture) wavefront phase tip and tilt aberrations using controllable rapid displacement of the tip of the delivery fiber at the collimating lens focal plane. In the technique proposed, this tip and tilt phase aberration control is based on maximization of the optical power received through the same fiber collimator using the stochastic parallel gradient descent (SPGD) technique. The coordinates of the fiber tip after the local tip and tilt aberrations are mitigated correspond to the coordinates of the focal-spot centroid of the optical wave backscattered off the target. Similar to a conventional Shack-Hartmann wavefront sensor, phase function over the entire fiber-array aperture can then be retrieved using the coordinates obtained. The piston phases that are required for coherent combining (phase locking) of the outgoing beams at the target plane can be further calculated from the reconstructed wavefront phase. Results of analysis and numerical simulations are presented. Performance of adaptive precompensation of phase aberrations in this laser beam projection system type is compared for various system configurations characterized by the number of fiber collimators and atmospheric turbulence conditions. The wavefront control concept presented can be effectively applied for long-range laser beam projection scenarios for which the time delay related with the double-pass laser beam propagation to the target and back is compared or even exceeds the characteristic time of the atmospheric turbulence change - scenarios when conventional target-in-the-loop phase-locking techniques fail.
Technical Communication in the 21st Century: Where Are We Going?
ERIC Educational Resources Information Center
Killingsworth, M. Jimmie
1999-01-01
Explores how technical communicators arrive at their attitudes toward the future and the effects of such attitudes toward current practice. Argues for a critically informed, open-minded approach to the future, an approach that encourages an honest self-criticism within the discipline of technical communication. (SC)
Wilma Winds Whip Mexico Yucatan
2005-10-21
The eye of Hurricane Wilma, a menacing Category 4 storm, approaches the northeastern tip of Mexico Yucatan Peninsula in this October 21 image from NASA QuikScat satellite, depicting relative wind speeds and direction.
The most effective strategy for controlling pests in your lawn and garden may be to combine methods in an approach known as Integrated Pest Management. See videos and find tips for implementing IPM at your residence.
[Effective communication with talkative patients: 10 tips].
Giroldi, Esther; Veldhuijzen, Wemke; Bareman, Frits; Bueving, Herman; van der Weijden, Trudy; van der Vleuten, Cees; Muris, Jean
2016-01-01
Consultations with talkative patients present a challenge to doctors. It is difficult to gather all the necessary information within the available time, without damaging the doctor-patient relationship. Based on the listed existing literature and doctors' experiences, we present ten tips for gathering information from talkative patients in an effective manner whilst maintaining a good therapeutic alliance. In consultations with talkative patients, it is important to explore the cause of patients' talkativeness and to adapt one's communication approach accordingly.- Familiar communication strategies such as 'summarizing' can still be applied. When taking this route, a more directive communication approach--e.g. by means of a 'closed-ended summary'--can prevent the patient interrupting the doctor or departing from his subject. There are strategies aimed at avoiding a damaging effect to the doctor-patient relationship when applying this approach: don't be overly directive, make the patient co-responsible for efficient time management in the consultation, and make use of empathic interrupting and humour.
Self-Recirculating Casing Treatment Concept for Enhanced Compressor Performance
NASA Technical Reports Server (NTRS)
Hathaway, Michael D.
2002-01-01
A state-of-the-art CFD code (APNASA) was employed in a computationally based investigation of the impact of casing bleed and injection on the stability and performance of a moderate speed fan rotor wherein the stalling mass flow is controlled by tip flow field breakdown. The investigation was guided by observed trends in endwall flow characteristics (e.g., increasing endwall aerodynamic blockage) as stall is approached and based on the hypothesis that application of bleed or injection can mitigate these trends. The "best" bleed and injection configurations were then combined to yield a self-recirculating casing treatment concept. The results of this investigation yielded: 1) identification of the fluid mechanisms which precipitate stall of tip critical blade rows, and 2) an approach to recirculated casing treatment which results in increased compressor stall range with minimal or no loss in efficiency. Subsequent application of this approach to a high speed transonic rotor successfully yielded significant improvements in stall range with no loss in compressor efficiency.
Cross-validated detection of crack initiation in aerospace materials
NASA Astrophysics Data System (ADS)
Vanniamparambil, Prashanth A.; Cuadra, Jefferson; Guclu, Utku; Bartoli, Ivan; Kontsos, Antonios
2014-03-01
A cross-validated nondestructive evaluation approach was employed to in situ detect the onset of damage in an Aluminum alloy compact tension specimen. The approach consisted of the coordinated use primarily the acoustic emission, combined with the infrared thermography and digital image correlation methods. Both tensile loads were applied and the specimen was continuously monitored using the nondestructive approach. Crack initiation was witnessed visually and was confirmed by the characteristic load drop accompanying the ductile fracture process. The full field deformation map provided by the nondestructive approach validated the formation of a pronounced plasticity zone near the crack tip. At the time of crack initiation, a burst in the temperature field ahead of the crack tip as well as a sudden increase of the acoustic recordings were observed. Although such experiments have been attempted and reported before in the literature, the presented approach provides for the first time a cross-validated nondestructive dataset that can be used for quantitative analyses of the crack initiation information content. It further allows future development of automated procedures for real-time identification of damage precursors including the rarely explored crack incubation stage in fatigue conditions.
Near-Field Spectroscopy with Nanoparticles Deposited by AFM
NASA Technical Reports Server (NTRS)
Anderson, Mark S.
2008-01-01
An alternative approach to apertureless near-field optical spectroscopy involving an atomic-force microscope (AFM) entails less complexity of equipment than does a prior approach. The alternative approach has been demonstrated to be applicable to apertureless near-field optical spectroscopy of the type using an AFM and surface enhanced Raman scattering (SERS), and is expected to be equally applicable in cases in which infrared or fluorescence spectroscopy is used. Apertureless near-field optical spectroscopy is a means of performing spatially resolved analyses of chemical compositions of surface regions of nanostructured materials. In apertureless near-field spectroscopy, it is common practice to utilize nanostructured probe tips or nanoparticles (usually of gold) having shapes and dimensions chosen to exploit plasmon resonances so as to increase spectroscopic-signal strengths. To implement the particular prior approach to which the present approach is an alternative, it is necessary to integrate a Raman spectrometer with an AFM and to utilize a special SERS-active probe tip. The resulting instrumentation system is complex, and the tasks of designing and constructing the system and using the system to acquire spectro-chemical information from nanometer-scale regions on a surface are correspondingly demanding.
Baig, Zeeshan; Mamat, Othman; Mustapha, Mazli; Mumtaz, Asad; Munir, Khurram S; Sarfraz, Mansoor
2018-07-01
The exceptional properties of graphene and its structural uniqueness can improve the performance of nanocomposites if it can attain the uniform dispersion. Tip sonication assisted graphene solvent dispersion has been emerged as an efficient approach but it can cause significant degradation of graphene structure. This study aimed to evaluate the parametric influence of tip sonication on the characteristics of sp 2 carbon structure in graphene nanoplatelets by varying the sonication time and respective energy at three different amplitudes (60%, 80% and 100%). The study is essential to identify appropriate parameters so as to achieve high-quality and defect-free graphene with a highly desirable aspect ratio after solvent dispersion for composite reinforcement. Quantitative approach via Raman spectroscopy is used to find the defect ratio and lateral size of graphene evolved under the effect of tip sonication parameters. Results imply that the defect ratio is steady and increases continually with GNPs, along with the transformation to the nano-crystalline stage I up to 60 min sonication at all amplitudes. Exfoliation was clearly observed at all amplitudes together with sheet re-stacking due to considerable size reduction of sheets with large quantity. Finally, considerable GNPs fragmentation occurred during sonication with increased amplitude and time as confirmed by the reduction of sp 2 domain (La) and flake size. This also validates the formation of edge-type defect in graphene. Convincingly, lower amplitude and time (up to 60 min) produce better results for a low defect content and larger particle size as quantified by Raman analysis. Copyright © 2018 Elsevier B.V. All rights reserved.
Suh, Dong Won; Han, Seung Beom; Yeo, Woo Jin; Lee, Won Hee; Kwon, Jae Ho; Kyung, Bong Soo
2017-01-01
Background: Tunnel widening (TW) after anterior cruciate ligament (ACL) reconstruction can be a serious complication, and there is controversy over how to prevent it. This study aimed to suggest surgical approaches to prevent TW using an allo-Achilles tendon graft, and then to evaluate TW after these surgical tips were applied. Materials and Methods: Sixty two patients underwent ACL reconstruction with an allo-Achilles tendon graft. Four surgical approaches were used: Making a tibial tunnel by bone impaction, intraarticular reamer application, bone portion application for the femoral tunnel, and an additional bone plug application for the tibial tunnel. After more than 1-year, followup radiographs including anteroposterior and lateral views were taken in 29 patients encompassing thirty knees. The diameter of the tunnels at postoperation day 1 (POD1) and at followup was measured and compared. Results: In 18 knees (60%), there were no visible femoral tunnel margins on the radiographs at POD1 or followup. In the other 12 cases, which had visible femoral tunnel margins on followup radiographs, the mean femoral tunnel diameter was 8.6 mm. In the tibial tunnel, the mean diameters did not increase on all three levels (proximal, middle, and distal), and there was no statistically significant difference between the diameters at POD1 and followup. Conclusion: The suggested tips for surgery involving an allo-Achilles tendon graft can effectively prevent TW after ACL reconstruction according to this case series. These surgical tips can prevent TW. PMID:28400663
Electrostatic contribution from solvent in modulating single-walled carbon nanotube association
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ou, Shu-Ching; Patel, Sandeep, E-mail: sapatel@udel.edu
We perform all-atom molecular dynamics simulations to compute the potential of mean force (PMF) between two (10,10) single-walled carbon nanotubes solvated in pure nonpolarizable SPC/E and polarizable TIP4P-FQ water, at various temperatures. In general, the reversible work required to bring two nanotubes from a dissociated state (free energy reference) to contact state (free energy minimum) is more favorable and less temperature-dependent in TIP4P-FQ than in SPC/E water models. In contrast, molecular properties and behavior of water such as the spatially-resolved water number density (intertube, intratube, or outer regions), for TIP4P-FQ are more sensitive to temperature than SPC/E. Decomposition of themore » solvent-induced PMF into different spatial regions suggests that TIP4P-FQ has stronger temperature dependence; the opposing destabilizing/stabilizing contributions from intertube water and more distal water balance each other and suppress the temperature dependence of total association free energy. Further investigation of hydrogen bonding network in intertube water reveals that TIP4P-FQ retains fewer hydrogen bonds than SPC/E, which correlates with the lower water number density in this region. This reduction of hydrogen bonds affects the intertube water dipoles. As the intertube volume decreases, TIP4P-FQ dipole moment approaches the gas phase value; the distribution of dipole magnitude also becomes narrower due to less average polarization/perturbation from other water molecules. Our results imply that the reduction of water under confinement may seem trivial, but underlying effects to structure and free energetics are non-negligible.« less
A Pragmatic Approach to Getting Published: 35 Tips for Early Career Researchers
Glover, Natasha M.; Antoniadi, Ioanna; George, Gavin M.; Götzenberger, Lars; Gutzat, Ruben; Koorem, Kadri; Liancourt, Pierre; Rutowicz, Kinga; Saharan, Krishna; You, Wanhui; Mayer, Philipp
2016-01-01
It is trite to say “publish or perish,” yet many early career researchers are often at a loss on how to best get their work published. With strong competition and many manuscripts submitted, it is difficult to convince editors and reviewers to opt for acceptance. A pragmatic approach to publishing may increase one's odds of success. Here, we – a group of postdocs in the field of plant science – present specific recommendations for early career scientists on advanced levels. We cannot provide a recipe-like set of instructions with success guaranteed, but we come from a broad background in plant science, with experience publishing in a number of journals of varying topics and impact factors. We provide tips, tricks, and tools for collaboration, journal selection, and achieving acceptance. PMID:27242817
Acoustic Power Transmission Through a Ducted Fan
NASA Technical Reports Server (NTRS)
Envia, Ed
2016-01-01
For high-speed ducted fans, when the rotor flowfield is shock-free, the main contribution to the inlet radiated acoustic power comes from the portion of the rotor stator interaction sound field that is transmitted upstream through the rotor. As such, inclusion of the acoustic transmission is an essential ingredient in the prediction of the fan inlet noise when the fan tip relative speed is subsonic. This paper describes a linearized Euler based approach to computing the acoustic transmission of fan tones through the rotor. The approach is embodied in a code called LINFLUX was applied to a candidate subsonic fan called the Advanced Ducted Propulsor (ADP). The results from this study suggest that it is possible to make such prediction with sufficient fidelity to provide an indication of the acoustic transmission trends with the fan tip speed.
Quality Concerns in Technical Education in India: A Quantifiable Quality Enabled Model
ERIC Educational Resources Information Center
Gambhir, Victor; Wadhwa, N. C.; Grover, Sandeep
2016-01-01
Purpose: The paper aims to discuss current Technical Education scenarios in India. It proposes modelling the factors affecting quality in a technical institute and then applying a suitable technique for assessment, comparison and ranking. Design/methodology/approach: The paper chose graph theoretic approach for quantification of quality-enabled…
Training and Maintaining System-Wide Reliability in Outcome Management.
Barwick, Melanie A; Urajnik, Diana J; Moore, Julia E
2014-01-01
The Child and Adolescent Functional Assessment Scale (CAFAS) is widely used for outcome management, for providing real time client and program level data, and the monitoring of evidence-based practices. Methods of reliability training and the assessment of rater drift are critical for service decision-making within organizations and systems of care. We assessed two approaches for CAFAS training: external technical assistance and internal technical assistance. To this end, we sampled 315 practitioners trained by external technical assistance approach from 2,344 Ontario practitioners who had achieved reliability on the CAFAS. To assess the internal technical assistance approach as a reliable alternative training method, 140 practitioners trained internally were selected from the same pool of certified raters. Reliabilities were high for both practitioners trained by external technical assistance and internal technical assistance approaches (.909-.995, .915-.997, respectively). 1 and 3-year estimates showed some drift on several scales. High and consistent reliabilities over time and training method has implications for CAFAS training of behavioral health care practitioners, and the maintenance of CAFAS as a global outcome management tool in systems of care.
From Kondo to local singlet state in graphene nanoribbons with magnetic impurities
NASA Astrophysics Data System (ADS)
Diniz, G. S.; Luiz, G. I.; Latgé, A.; Vernek, E.
2018-03-01
A detailed analysis of the Kondo effect of a magnetic impurity in a zigzag graphene nanoribbon is addressed. An adatom is coupled to the graphene nanoribbon via a hybridization amplitude Γimp in a hollow- or top-site configuration. In addition, the adatom is also weakly coupled to a metallic scanning tunnel microscope (STM) tip by a hybridization function Γtip that provides a Kondo screening of its magnetic moment. The entire system is described by an Anderson-like Hamiltonian whose low-temperature physics is accessed by employing the numerical renormalization-group approach, which allows us to obtain the thermodynamic properties used to compute the Kondo temperature of the system. We find two screening regimes when the adatom is close to the edge of the zigzag graphene nanoribbon: (1) a weak-coupling regime (Γimp≪Γtip ), in which the edge states produce an enhancement of the Kondo temperature TK, and (2) a strong-coupling regime (Γimp≫Γtip ), in which a local singlet is formed, to the detriment of the Kondo screening by the STM tip. These two regimes can be clearly distinguished by the dependence of their characteristic temperature T* on the coupling between the adatom and the carbon sites of the graphene nanoribbon Vimp. We observe that in the weak-coupling regime T* increases exponentially with Vimp2. Differently, in the strong-coupling regime, T* increases linearly with Vimp2.
Forensic DNA typing from teeth using demineralized root tips.
Corrêa, Heitor Simões Dutra; Pedro, Fabio Luis Miranda; Volpato, Luiz Evaristo Ricci; Pereira, Thiago Machado; Siebert Filho, Gilberto; Borges, Álvaro Henrique
2017-11-01
Teeth are widely used samples in forensic human genetic identification due to their persistence and practical sampling and processing. Their processing, however, has changed very little in the last 20 years, usually including powdering or pulverization of the tooth. The objective of this study was to present demineralized root tips as DNA sources while, at the same time, not involving powdering the samples or expensive equipment for teeth processing. One to five teeth from each of 20 unidentified human bodies recovered from midwest Brazil were analyzed. Whole teeth were demineralized in EDTA solution with daily solution change. After a maximum of approximately seven days, the final millimeters of the root tip was excised. This portion of the sample was used for DNA extraction through a conventional organic protocol. DNA quantification and STR amplification were performed using commercial kits followed by capillary electrophoresis on 3130 or 3500 genetic analyzers. For 60% of the unidentified bodies (12 of 20), a full genetic profile was obtained from the extraction of the first root tip. By the end of the analyses, full genetic profiles were obtained for 85% of the individuals studied, of which 80% were positively identified. This alternative low-tech approach for postmortem teeth processing is capable of extracting DNA in sufficient quantity and quality for forensic casework, showing that root tips are viable nuclear DNA sources even after demineralization. Copyright © 2017 Elsevier B.V. All rights reserved.
SMART micro-scissors with dual motors and OCT sensors (Conference Presentation)
NASA Astrophysics Data System (ADS)
Yeo, Chaebeom; Jang, Seonjin; Park, Hyun-cheol; Gehlbach, Peter L.; Song, Cheol
2017-02-01
Various end-effectors of microsurgical instruments have been developed and studied. Also, many approaches to stabilize the tool-tip using robotics have been studied such as the steady hand robot system, Micron, and SMART system. In our previous study, the horizontal SMART micro-scissors with a common path swept source OCT distance and one linear piezoelectric (PZT) motor was demonstrated as a microsurgical system. Because the outer needle is connected with a mechanical handle and moved to engage the tool tip manually, the tool tip position is instantaneously changed during the engaging. The undesirable motion can make unexpected tissue damages and low surgical accuracy. In this study, we suggest a prototype horizontal SMART micro-scissors which has dual OCT sensors and two motors to improve the tremor cancellation. Dual OCT sensors provide two distance information. Front OCT sensor detects a distance from the sample surface to the tool tip. Rear OCT sensors gives current PZT motor movement, acting like a motor encoder. The PZT motor can compensate the hand tremor with a feedback loop control. The manual engaging of tool tip in previous SMART system is replaced by electrical engaging using a squiggle motor. Compared with previous study, this study showed better performance in the hand tremor reduction. From the result, the SMART with automatic engaging may become increasingly valuable in microsurgical instruments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kew, Jacqueline; Davies, Roger P.
2004-01-15
A new method is described for guiding hepato-portalvenous puncture using a longitudinal side-view intravascular ultrasound(L-IVUS) transducer to assist in the performance of transjugularintrahepatic portosystemic shunt (TIPS) in three Australian swine.Simultaneous L-IVUS with an AcuNav (registered) 5-10 MHz 10 Fr transducer(Acuson Corporation, Mountain View, CA, USA) and fluoroscopy guidance was used to image and monitor the hepatic to portal venous puncture,dilatation of the tract, and deployment of the TIPS stent. Flow through the shunt could be demonstrated with both L-IVUS and angiography. TIPS was successful in all swine. The time for portal vein puncture once the target portal vein was identifiedmore » was reduced at each attempt. The number of portal vein puncture attempts was 2, 1, and 1. No post-procedural complication was evident. L-IVUS-guided TIPS is practical and has the potential to improve safety by permitting simultaneous ultrasound and fluoroscopic imaging of the needle and target vascular structures. This technique allows for a more streamlined approach to TIPS, decreasing the fluoroscopic time (hence,decreasing the radiation exposure to the staff and patient) and anesthetic time. In addition, there are improved safety benefits obviating the need for wedged portography, facilitating avoidance of bile duct and hepatic arterial puncture, and minimizing hepatic injury by decreasing liver capsular puncture and the attendant risks.« less
Coral Reef Resilience, Tipping Points and the Strength of Herbivory
Holbrook, Sally J.; Schmitt, Russell J.; Adam, Thomas C.; Brooks, Andrew J.
2016-01-01
Coral reefs increasingly are undergoing transitions from coral to macroalgal dominance. Although the functional roles of reef herbivores in controlling algae are becoming better understood, identifying possible tipping points in the herbivory-macroalgae relationships has remained a challenge. Assessment of where any coral reef ecosystem lies in relation to the coral-to-macroalgae tipping point is fundamental to understanding resilience properties, forecasting state shifts, and developing effective management practices. We conducted a multi-year field experiment in Moorea, French Polynesia to estimate these properties. While we found a sharp herbivory threshold where macroalgae escape control, ambient levels of herbivory by reef fishes were well above that needed to prevent proliferation of macroalgae. These findings are consistent with previously observed high resilience of the fore reef in Moorea. Our approach can identify vulnerable coral reef systems in urgent need of management action to both forestall shifts to macroalgae and preserve properties essential for resilience. PMID:27804977
Virtual Tool Mark Generation for Efficient Striation Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekstrand, Laura; Zhang, Song; Grieve, Taylor
2014-02-16
This study introduces a tool mark analysis approach based upon 3D scans of screwdriver tip and marked plate surfaces at the micrometer scale from an optical microscope. An open-source 3D graphics software package is utilized to simulate the marking process as the projection of the tip's geometry in the direction of tool travel. The edge of this projection becomes a virtual tool mark that is compared to cross-sections of the marked plate geometry using the statistical likelihood algorithm introduced by Chumbley et al. In a study with both sides of six screwdriver tips and 34 corresponding marks, the method distinguishedmore » known matches from known nonmatches with zero false-positive matches and two false-negative matches. For matches, it could predict the correct marking angle within ±5–10°. Individual comparisons could be made in seconds on a desktop computer, suggesting that the method could save time for examiners.« less
Velocity Dependence of the Kinetic Friction of Nanoparticles
NASA Astrophysics Data System (ADS)
Dietzel, Dirk; Feldmann, Michael; Schirmeisen, Andre
2010-03-01
The velocity dependence of interfacial friction is of high interest to unveil the fundamental processes in nanoscopic friction. So far, different forms of velocity dependence have been observed for contacts between friction force microscope (FFM) tips and a substrate surface. In this work we present velocity-dependent friction measurements performed by nanoparticle manipulation of antimony nanoparticles on atomically flat HOPG substrates under UHV conditions. This allows to analyze interfacial friction for very well defined and clean surface contacts. A novel approach to nanoparticle manipulation, the so called 'tip-on-top' technique [1], made it possible to manipulate the same particle many times while varying the velocity. The antimony particles exhibit a qualitatively different velocity dependence on friction in comparison to direct tip-HOPG contacts. A characteristic change in velocity dependence was observed when comparing freshly prepared particles to contaminated specimen, which were exposed to air before the manipulation experiments. [1] Dietzel et al., Appl. Phys. Lett. 95, 53104 (2009)
Trevethan, Thomas; Shluger, Alexander
2009-07-01
We present the results of theoretical modelling that predicts how a process of transfer of single electrons between two defects on an insulating surface can be induced using a scanning force microscope tip. A model but realistic system is employed which consists of a neutral oxygen vacancy and a noble metal (Pt or Pd) adatom on the MgO(001) surface. We show that the ionization potential of the vacancy and the electron affinity of the metal adatom can be significantly modified by the electric field produced by an ionic tip apex at close approach to the surface. The relative energies of the two states are also a function of the separation of the two defects. Therefore the transfer of an electron from the vacancy to the metal adatom can be induced either by the field effect of the tip or by manipulating the position of the metal adatom on the surface.
NASA Astrophysics Data System (ADS)
Matz, Gregor; Messerschmidt, Bernhard; Göbel, Werner; Filser, Severin; Betz, Christian; Kunze, Marcel; Flaemig, Sven; Ehrhardt, André; Irion, Klaus-Martin; Herms, Jochen; Gross, Herbert
2017-02-01
We demonstrate a flexible stand-alone, minimally invasive video-endomicroscope with an outer diameter of 1.6 mm and a length of the rigid tip of 6.7 mm that enables surgeons and biologists to image hardly accessible regions in-vivo in epifluorescence mode. The 60 mg light device improves state-of-the-art objectives by a double deflection approach using a side-fire fiber in combination with spherical microlenses, GRIN-lenses with a specific adapted gradient index profile and an extremely miniaturized chip-on-the-tip camera to achieve an excellent imaging quality. A high NA of 0.7 enables the observation of subcellular features within the entire field of view with a diameter of 183 μm, assure a bright and high-contrast image and promise a good overview during the intervention. Ex-vivo measurements of biological samples confirmed the functionality of the probe.
Bioinspired Composite Microfibers for Skin Adhesion and Signal Amplification of Wearable Sensors.
Drotlef, Dirk-M; Amjadi, Morteza; Yunusa, Muhammad; Sitti, Metin
2017-07-01
A facile approach is proposed for superior conformation and adhesion of wearable sensors to dry and wet skin. Bioinspired skin-adhesive films are composed of elastomeric microfibers decorated with conformal and mushroom-shaped vinylsiloxane tips. Strong skin adhesion is achieved by crosslinking the viscous vinylsiloxane tips directly on the skin surface. Furthermore, composite microfibrillar adhesive films possess a high adhesion strength of 18 kPa due to the excellent shape adaptation of the vinylsiloxane tips to the multiscale roughness of the skin. As a utility of the skin-adhesive films in wearable-device applications, they are integrated with wearable strain sensors for respiratory and heart-rate monitoring. The signal-to-noise ratio of the strain sensor is significantly improved to 59.7 because of the considerable signal amplification of microfibrillar skin-adhesive films. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Coral Reef Resilience, Tipping Points and the Strength of Herbivory.
Holbrook, Sally J; Schmitt, Russell J; Adam, Thomas C; Brooks, Andrew J
2016-11-02
Coral reefs increasingly are undergoing transitions from coral to macroalgal dominance. Although the functional roles of reef herbivores in controlling algae are becoming better understood, identifying possible tipping points in the herbivory-macroalgae relationships has remained a challenge. Assessment of where any coral reef ecosystem lies in relation to the coral-to-macroalgae tipping point is fundamental to understanding resilience properties, forecasting state shifts, and developing effective management practices. We conducted a multi-year field experiment in Moorea, French Polynesia to estimate these properties. While we found a sharp herbivory threshold where macroalgae escape control, ambient levels of herbivory by reef fishes were well above that needed to prevent proliferation of macroalgae. These findings are consistent with previously observed high resilience of the fore reef in Moorea. Our approach can identify vulnerable coral reef systems in urgent need of management action to both forestall shifts to macroalgae and preserve properties essential for resilience.
Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breault, Stéphane, E-mail: stephane.breault@chuv.ch; Glauser, Frédéric, E-mail: frederic.glauser@chuv.ch; Babaker, Malik, E-mail: malik.babaker@chuv.ch
2015-06-15
PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis”more » maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.« less
Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2017-02-01
A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.
Granados, Alejandro; Vakharia, Vejay; Rodionov, Roman; Schweiger, Martin; Vos, Sjoerd B; O'Keeffe, Aidan G; Li, Kuo; Wu, Chengyuan; Miserocchi, Anna; McEvoy, Andrew W; Clarkson, Matthew J; Duncan, John S; Sparks, Rachel; Ourselin, Sébastien
2018-06-01
The accurate and automatic localisation of SEEG electrodes is crucial for determining the location of epileptic seizure onset. We propose an algorithm for the automatic segmentation of electrode bolts and contacts that accounts for electrode bending in relation to regional brain anatomy. Co-registered post-implantation CT, pre-implantation MRI, and brain parcellation images are used to create regions of interest to automatically segment bolts and contacts. Contact search strategy is based on the direction of the bolt with distance and angle constraints, in addition to post-processing steps that assign remaining contacts and predict contact position. We measured the accuracy of contact position, bolt angle, and anatomical region at the tip of the electrode in 23 post-SEEG cases comprising two different surgical approaches when placing a guiding stylet close to and far from target point. Local and global bending are computed when modelling electrodes as elastic rods. Our approach executed on average in 36.17 s with a sensitivity of 98.81% and a positive predictive value (PPV) of 95.01%. Compared to manual segmentation, the position of contacts had a mean absolute error of 0.38 mm and the mean bolt angle difference of [Formula: see text] resulted in a mean displacement error of 0.68 mm at the tip of the electrode. Anatomical regions at the tip of the electrode were in strong concordance with those selected manually by neurosurgeons, [Formula: see text], with average distance between regions of 0.82 mm when in disagreement. Our approach performed equally in two surgical approaches regardless of the amount of electrode bending. We present a method robust to electrode bending that can accurately segment contact positions and bolt orientation. The techniques presented in this paper will allow further characterisation of bending within different brain regions.
ERIC Educational Resources Information Center
Beller, Jennifer M.
2013-01-01
This article describes a programmatic approach to undergraduate research (UGR) at Washington State University. In a programmatic approach, UGR is woven throughout the curriculum, with the expressed intent of producing undergraduate students who have at least a moderate ability to read, use, conduct, and present research. Washington State…
Fabrication of mesoporous polymer monolith: a template-free approach.
Okada, Keisuke; Nandi, Mahasweta; Maruyama, Jun; Oka, Tatsuya; Tsujimoto, Takashi; Kondoh, Katsuyoshi; Uyama, Hiroshi
2011-07-14
Mesoporous polyacrylonitrile (PAN) monolith has been fabricated by a template-free approach using the unique affinity of PAN towards a water/dimethyl sulfoxide (DMSO) mixture. A newly developed Thermally Induced Phase Separation Technique (TIPS) has been used to obtain the polymer monoliths and their microstructures have been controlled by optimizing the concentration and cooling temperature.
Identifying Technical Vocabulary
ERIC Educational Resources Information Center
Chung, Teresa Mihwa; Nation, Paul
2004-01-01
This study compared four different approaches to identifying technical words in an anatomy text. The first approach used a four step rating scale, and was used as the comparison for evaluating the other three approaches. It had a high degree of reliability. The least successful approach was that using clues provided by the writer such as labels in…
Jurling, Alden S; Fienup, James R
2014-03-01
Extending previous work by Thurman on wavefront sensing for segmented-aperture systems, we developed an algorithm for estimating segment tips and tilts from multiple point spread functions in different defocused planes. We also developed methods for overcoming two common modes for stagnation in nonlinear optimization-based phase retrieval algorithms for segmented systems. We showed that when used together, these methods largely solve the capture range problem in focus-diverse phase retrieval for segmented systems with large tips and tilts. Monte Carlo simulations produced a rate of success better than 98% for the combined approach.
Airplane wing vibrations due to atmospheric turbulence
NASA Technical Reports Server (NTRS)
Pastel, R. L.; Caruthers, J. E.; Frost, W.
1981-01-01
The magnitude of error introduced due to wing vibration when measuring atmospheric turbulence with a wind probe mounted at the wing tip was studied. It was also determined whether accelerometers mounted on the wing tip are needed to correct this error. A spectrum analysis approach is used to determine the error. Estimates of the B-57 wing characteristics are used to simulate the airplane wing, and von Karman's cross spectrum function is used to simulate atmospheric turbulence. It was found that wing vibration introduces large error in measured spectra of turbulence in the frequency's range close to the natural frequencies of the wing.
The initiation, propagation, and effect of matrix microcracks in cross-ply and related laminates
NASA Technical Reports Server (NTRS)
Nairn, John A.; Hu, Shoufeng; Liu, Siulie; Bark, Jong
1991-01-01
Recently, a variational mechanics approach was used to determine the thermoelastic stress state in cracked laminates. Described here is a generalization of the variational mechanics techniques to handle other cross-ply laminates, related laminates, and to account for delaminations emanating from microcrack tips. Microcracking experiments on Hercules 3501-6/AS4 carbon fiber/epoxy laminates show a staggered cracking pattern. These results can be explained by the variational mechanics analysis. The analysis of delaminations emanating from microcrack tips has resulted in predictions about the structural and material variables controlling competition between microcracking and delamination failure modes.
NASA Technical Reports Server (NTRS)
Sekula, Martin K.
2012-01-01
Projection moir interferometry (PMI) was employed to measure blade deflections during a hover test of a generic model-scale rotor in the NASA Langley 14x22 subsonic wind tunnel s hover facility. PMI was one of several optical measurement techniques tasked to acquire deflection and flow visualization data for a rotor at several distinct heights above a ground plane. Two of the main objectives of this test were to demonstrate that multiple optical measurement techniques can be used simultaneously to acquire data and to identify and address deficiencies in the techniques. Several PMI-specific technical challenges needed to be addressed during the test and in post-processing of the data. These challenges included developing an efficient and accurate calibration method for an extremely large (65 inch) height range; automating the analysis of the large amount of data acquired during the test; and developing a method to determinate the absolute displacement of rotor blades without a required anchor point measurement. The results indicate that the use of a single-camera/single-projector approach for the large height range reduced the accuracy of the PMI system compared to PMI systems designed for smaller height ranges. The lack of the anchor point measurement (due to a technical issue with one of the other measurement techniques) limited the ability of the PMI system to correctly measure blade displacements to only one of the three rotor heights tested. The new calibration technique reduced the data required by 80 percent while new post-processing algorithms successfully automated the process of locating rotor blades in images, determining the blade quarter chord location, and calculating the blade root and blade tip heights above the ground plane.
Gonenc, Berk; Chae, Jeremy; Gehlbach, Peter; Taylor, Russell H.; Iordachita, Iulian
2017-01-01
Retinal vein cannulation is a technically demanding surgical procedure where therapeutic agents are injected into the retinal veins to treat occlusions. The clinical feasibility of this approach has been largely limited by the technical challenges associated with performing the procedure. Among the challenges to successful vein cannulation are identifying the moment of venous puncture, achieving cannulation of the micro-vessel, and maintaining cannulation throughout drug delivery. Recent advances in medical robotics and sensing of tool-tissue interaction forces have the potential to address each of these challenges as well as to prevent tissue trauma, minimize complications, diminish surgeon effort, and ultimately promote successful retinal vein cannulation. In this paper, we develop an assistive system combining a handheld micromanipulator, called “Micron”, with a force-sensing microneedle. Using this system, we examine two distinct methods of precisely detecting the instant of venous puncture. This is based on measured tool-tissue interaction forces and also the tracked position of the needle tip. In addition to the existing tremor canceling function of Micron, a new control method is implemented to actively compensate unintended movements of the operator, and to keep the cannulation device securely inside the vein following cannulation. To demonstrate the capabilities and performance of our uniquely upgraded system, we present a multi-user artificial phantom study with subjects from three different surgical skill levels. Results show that our puncture detection algorithm, when combined with the active positive holding feature enables sustained cannulation which is most evident in smaller veins. Notable is that the active holding function significantly attenuates tool motion in the vein, thereby reduces the trauma during cannulation. PMID:28946634
NASA Astrophysics Data System (ADS)
Hou, Fang
With the extensive application of fiber-reinforced composite laminates in industry, research on the fracture mechanisms of this type of materials have drawn more and more attentions. A variety of fracture theories and models have been developed. Among them, the linear elastic fracture mechanics (LEFM) and cohesive-zone model (CZM) are two widely-accepted fracture models, which have already shown applicability in the fracture analysis of fiber-reinforced composite laminates. However, there remain challenges which prevent further applications of the two fracture models, such as the experimental measurement of fracture resistance. This dissertation primarily focused on the study of the applicability of LEFM and CZM for the fracture analysis of translaminar fracture in fibre-reinforced composite laminates. The research for each fracture model consisted of two sections: the analytical characterization of crack-tip fields and the experimental measurement of fracture resistance parameters. In the study of LEFM, an experimental investigation based on full-field crack-tip displacement measurements was carried out as a way to characterize the subcritical and steady-state crack advances in translaminar fracture of fiber-reinforced composite laminates. Here, the fiber-reinforced composite laminates were approximated as anisotropic solids. The experimental investigation relied on the LEFM theory with a modification with respect to the material anisotropy. Firstly, the full-field crack-tip displacement fields were measured by Digital Image Correlation (DIC). Then two methods, separately based on the stress intensity approach and the energy approach, were developed to measure the crack-tip field parameters from crack-tip displacement fields. The studied crack-tip field parameters included the stress intensity factor, energy release rate and effective crack length. Moreover, the crack-growth resistance curves (R-curves) were constructed with the measured crack-tip field parameters. In addition, an error analysis was carried out with an emphasis on the influence of out-of-plane rotation of specimen. In the study of CZM, two analytical inverse methods, namely the field projection method (FPM) and the separable nonlinear least-squares method, were developed for the extraction of cohesive fracture properties from crack-tip full-field displacements. Firstly, analytical characterizations of the elastic fields around a crack-tip cohesive zone and the cohesive variables within the cohesive zone were derived in terms of an eigenfunction expansion. Then both of the inverse methods were developed based on the analytical characterization. With the analytical inverse methods, the cohesive-zone law (CZL), cohesive-zone size and position can be inversely computed from the cohesive-crack-tip displacement fields. In the study, comprehensive numerical tests were carried out to investigate the applicability and robustness of two inverse methods. From the numerical tests, it was found that the field projection method was very sensitive to noise and thus had limited applicability in practice. On the other hand, the separable nonlinear least-squares method was found to be more noise-resistant and less ill-conditioned. Subsequently, the applicability of separable nonlinear least-squares method was validated with the same translaminar fracture experiment for the study of LEFM. Eventually, it was found that the experimental measurements of R-curves and CZL showed a great agreement, in both of the fracture energy and the predicted load carrying capability. It thus demonstrated the validity of present research for the translaminar fracture of fiber-reinforced composite laminates.
Radiation Effects in M and NEMS
2016-03-31
10.1117/12.876968 casing mobile core AFM tip Pt wire x δ a Figure 5. Proposed approach to combine single crystal silicon MEMS (Sandia) fab capabilities and form supporting structure for 2D materials (VU). 198
Neural adaptive control for vibration suppression in composite fin-tip of aircraft.
Suresh, S; Kannan, N; Sundararajan, N; Saratchandran, P
2008-06-01
In this paper, we present a neural adaptive control scheme for active vibration suppression of a composite aircraft fin tip. The mathematical model of a composite aircraft fin tip is derived using the finite element approach. The finite element model is updated experimentally to reflect the natural frequencies and mode shapes very accurately. Piezo-electric actuators and sensors are placed at optimal locations such that the vibration suppression is a maximum. Model-reference direct adaptive neural network control scheme is proposed to force the vibration level within the minimum acceptable limit. In this scheme, Gaussian neural network with linear filters is used to approximate the inverse dynamics of the system and the parameters of the neural controller are estimated using Lyapunov based update law. In order to reduce the computational burden, which is critical for real-time applications, the number of hidden neurons is also estimated in the proposed scheme. The global asymptotic stability of the overall system is ensured using the principles of Lyapunov approach. Simulation studies are carried-out using sinusoidal force functions of varying frequency. Experimental results show that the proposed neural adaptive control scheme is capable of providing significant vibration suppression in the multiple bending modes of interest. The performance of the proposed scheme is better than the H(infinity) control scheme.
Molecular Identification of Ectomycorrhizal Mycelium in Soil Horizons
Landeweert, Renske; Leeflang, Paula; Kuyper, Thom W.; Hoffland, Ellis; Rosling, Anna; Wernars, Karel; Smit, Eric
2003-01-01
Molecular identification techniques based on total DNA extraction provide a unique tool for identification of mycelium in soil. Using molecular identification techniques, the ectomycorrhizal (EM) fungal community under coniferous vegetation was analyzed. Soil samples were taken at different depths from four horizons of a podzol profile. A basidiomycete-specific primer pair (ITS1F-ITS4B) was used to amplify fungal internal transcribed spacer (ITS) sequences from total DNA extracts of the soil horizons. Amplified basidiomycete DNA was cloned and sequenced, and a selection of the obtained clones was analyzed phylogenetically. Based on sequence similarity, the fungal clone sequences were sorted into 25 different fungal groups, or operational taxonomic units (OTUs). Out of 25 basidiomycete OTUs, 7 OTUs showed high nucleotide homology (≥99%) with known EM fungal sequences and 16 were found exclusively in the mineral soil. The taxonomic positions of six OTUs remained unclear. OTU sequences were compared to sequences from morphotyped EM root tips collected from the same sites. Of the 25 OTUs, 10 OTUs had ≥98% sequence similarity with these EM root tip sequences. The present study demonstrates the use of molecular techniques to identify EM hyphae in various soil types. This approach differs from the conventional method of EM root tip identification and provides a novel approach to examine EM fungal communities in soil. PMID:12514012
Bauer, Brad A.; Patel, Sandeep
2009-01-01
We present an extension of the TIP4P-QDP model, TIP4P-QDP-LJ, that is designed to couple changes in repulsive and dispersive nonbond interactions to changes in polarizability. Polarizability is intimately related to the dispersion component of classical force field models of interactions, and we explore the effect of incorporating this connection explicitly on properties along the liquid-vapor coexistence curve of pure water. Parametrized to reproduce condensed-phase liquid water properties at 298 K, the TIP4P-QDP-LJ model predicts density, enthalpy of vaporization, self-diffusion constant, and the dielectric constant at ambient conditions to about the same accuracy as TIP4P-QDP but shows remarkable improvement in reproducing the liquid-vapor coexistence curve. TIP4P-QDP-LJ predicts critical constants of Tc=623 K, ρc=0.351 g∕cm3, and Pc=250.9 atm, which are in good agreement with experimental values of Tc=647.1 K, ρc=0.322 g∕cm3, and Pc=218 atm, respectively. Applying a scaling factor correction (obtained by fitting the experimental vapor-liquid equilibrium data to the law of rectilinear diameters using a three-term Wegner expansion) the model predicts critical constants (Tc=631 K and ρc=0.308 g∕cm3). Dependence of enthalpy of vaporization, self-diffusion constant, surface tension, and dielectric constant on temperature are shown to reproduce experimental trends. We also explore the interfacial potential drop across the liquid-vapor interface for the temperatures studied. The interfacial potential demonstrates little temperature dependence at lower temperatures (300–450 K) and significantly enhanced (exponential) dependence at elevated temperatures. Terms arising from the decomposition of the interfacial potential into dipole and quadrupole contributions are shown to monotonically approach zero as the temperature approaches the critical temperature. Results of this study suggest that self-consistently treating the coupling of phase-dependent polarizability with dispersion interactions in classical water force fields may be an important effect for the extension of polarizable water force fields to reproduce properties along the liquid-vapor coexistence envelope as well as near critical conditions. More importantly, the present study demonstrates the rather remarkable transferability of a water model parametrized to a single state point to other thermodynamic states. Further studies are recommended. PMID:19725623
Bauer, Brad A; Patel, Sandeep
2009-08-28
We present an extension of the TIP4P-QDP model, TIP4P-QDP-LJ, that is designed to couple changes in repulsive and dispersive nonbond interactions to changes in polarizability. Polarizability is intimately related to the dispersion component of classical force field models of interactions, and we explore the effect of incorporating this connection explicitly on properties along the liquid-vapor coexistence curve of pure water. Parametrized to reproduce condensed-phase liquid water properties at 298 K, the TIP4P-QDP-LJ model predicts density, enthalpy of vaporization, self-diffusion constant, and the dielectric constant at ambient conditions to about the same accuracy as TIP4P-QDP but shows remarkable improvement in reproducing the liquid-vapor coexistence curve. TIP4P-QDP-LJ predicts critical constants of T(c)=623 K, rho(c)=0.351 g/cm(3), and P(c)=250.9 atm, which are in good agreement with experimental values of T(c)=647.1 K, rho(c)=0.322 g/cm(3), and P(c)=218 atm, respectively. Applying a scaling factor correction (obtained by fitting the experimental vapor-liquid equilibrium data to the law of rectilinear diameters using a three-term Wegner expansion) the model predicts critical constants (T(c)=631 K and rho(c)=0.308 g/cm(3)). Dependence of enthalpy of vaporization, self-diffusion constant, surface tension, and dielectric constant on temperature are shown to reproduce experimental trends. We also explore the interfacial potential drop across the liquid-vapor interface for the temperatures studied. The interfacial potential demonstrates little temperature dependence at lower temperatures (300-450 K) and significantly enhanced (exponential) dependence at elevated temperatures. Terms arising from the decomposition of the interfacial potential into dipole and quadrupole contributions are shown to monotonically approach zero as the temperature approaches the critical temperature. Results of this study suggest that self-consistently treating the coupling of phase-dependent polarizability with dispersion interactions in classical water force fields may be an important effect for the extension of polarizable water force fields to reproduce properties along the liquid-vapor coexistence envelope as well as near critical conditions. More importantly, the present study demonstrates the rather remarkable transferability of a water model parametrized to a single state point to other thermodynamic states. Further studies are recommended.
Technically natural vacuum energy at the tip of a supersymmetric teardrop
NASA Astrophysics Data System (ADS)
Williams, Matthew
2014-04-01
A minimal supersymmetric braneworld model is presented which has (i) zero classical four-dimensional vacuum curvature, despite the large naive vacuum energy due to contributions from Standard Model particles and (ii) one-(bulk)-loop quantum corrections to the vacuum energy with a size set by the radius of the extra-dimensional spheroid. These corrections are technically natural because a Bogomol'nyi-Prasad-Sommerfield-like relation between the brane tension and R charge—which would have preserved (half of) the bulk supersymmetry—is violated by the requirement that the stabilizing R-symmetry gauge flux be quantized. The extra-dimensional geometry is similar to previous rugby-ball geometries, but is simpler in that there is only one brane and so fewer free parameters. Although the sign of the renormalized vacuum energy ends up being the unphysical one for this model (in the limit considered here, where the massive bulk loop is the leading contribution), it serves as an illustrative example of the relevant physics.
Imaging windows for long-term intravital imaging: General overview and technical insights.
Alieva, Maria; Ritsma, Laila; Giedt, Randy J; Weissleder, Ralph; van Rheenen, Jacco
2014-01-01
Intravital microscopy is increasingly used to visualize and quantitate dynamic biological processes at the (sub)cellular level in live animals. By visualizing tissues through imaging windows, individual cells (e.g., cancer, host, or stem cells) can be tracked and studied over a time-span of days to months. Several imaging windows have been developed to access tissues including the brain, superficial fascia, mammary glands, liver, kidney, pancreas, and small intestine among others. Here, we review the development of imaging windows and compare the most commonly used long-term imaging windows for cancer biology: the cranial imaging window, the dorsal skin fold chamber, the mammary imaging window, and the abdominal imaging window. Moreover, we provide technical details, considerations, and trouble-shooting tips on the surgical procedures and microscopy setups for each imaging window and explain different strategies to assure imaging of the same area over multiple imaging sessions. This review aims to be a useful resource for establishing the long-term intravital imaging procedure.
The effect of cutting conditions on power inputs when machining
NASA Astrophysics Data System (ADS)
Petrushin, S. I.; Gruby, S. V.; Nosirsoda, Sh C.
2016-08-01
Any technological process involving modification of material properties or product form necessitates consumption of a certain power amount. When developing new technologies one should take into account the benefits of their implementation vs. arising power inputs. It is revealed that procedures of edge cutting machining are the most energy-efficient amongst the present day forming procedures such as physical and technical methods including electrochemical, electroerosion, ultrasound, and laser processing, rapid prototyping technologies etc, such as physical and technical methods including electrochemical, electroerosion, ultrasound, and laser processing, rapid prototyping technologies etc. An expanded formula for calculation of power inputs is deduced, which takes into consideration the mode of cutting together with the tip radius, the form of the replaceable multifaceted insert and its wear. Having taken as an example cutting of graphite iron by the assembled cutting tools with replaceable multifaceted inserts the authors point at better power efficiency of high feeding cutting in comparison with high-speed cutting.
Spatially discrete thermal drawing of biodegradable microneedles for vascular drug delivery.
Choi, Chang Kuk; Lee, Kang Ju; Youn, Young Nam; Jang, Eui Hwa; Kim, Woong; Min, Byung-Kwon; Ryu, WonHyoung
2013-02-01
Spatially discrete thermal drawing is introduced as a novel method for the fabrication of biodegradable microneedles with ultra-sharp tip ends. This method provides the enhanced control of microneedle shapes by spatially controlling the temperature of drawn polymer as well as drawing steps and speeds. Particular focus is given on the formation of sharp tip ends of microneedles at the end of thermal drawing. Previous works relied on the fracture of polymer neck by fast drawing that often causes uncontrolled shapes of microneedle tips. Instead, this approach utilizes the surface energy of heated polymer to form ultra-sharp tip ends. We have investigated the effect of such temperature control, drawing speed, and drawing steps in thermal drawing process on the final shape of microneedles using biodegradable polymers. XRD analysis was performed to analyze the effect of thermal cycle on the biodegradable polymer. Load-displacement measurement also showed the dependency of mechanical strengths of microneedles on the microneedle shapes. Ex vivo vascular tissue insertion and drug delivery demonstrated microneedle insertion to tunica media layer of canine aorta and drug distribution in the tissue layer. Copyright © 2012 Elsevier B.V. All rights reserved.
Multi scale modeling of 2450MHz electric field effects on microtubule mechanical properties.
Setayandeh, S S; Lohrasebi, A
2016-11-01
Microtubule (MT) rigidity and response to 2450MHz electric fields were investigated, via multi scale modeling approach. For this purpose, six systems were designed and simulated to consider all types of feasible interactions between α and β monomers in MT, by using all atom molecular dynamics method. Subsequently, coarse grain modeling was used to design different lengths of MT. Investigation of effects of external 2450MHz electric field on MT showed MT less rigidity in the presence of such field, which may perturb its functions. Moreover, an additional computational setup was designed to study effects of 2450MHz field on MT response to AFM tip. It was found, more tip velocity led to MT faster transformation and less time was required to change MT elastic response to plastic one, applying constant radius. Moreover it was observed smaller tip caused to increase required time to change MT elastic response to plastic one, considering constant velocity. Furthermore, exposing MT to 2450MHz field led to no significant changes in MT response to AFM tip, but quick change in MT elastic response to plastic one. Copyright © 2016 Elsevier Inc. All rights reserved.
Sensitivity of collective action to uncertainty about climate tipping points
NASA Astrophysics Data System (ADS)
Barrett, Scott; Dannenberg, Astrid
2014-01-01
Despite more than two decades of diplomatic effort, concentrations of greenhouse gases continue to trend upwards, creating the risk that we may someday cross a threshold for `dangerous' climate change. Although climate thresholds are very uncertain, new research is trying to devise `early warning signals' of an approaching tipping point. This research offers a tantalizing promise: whereas collective action fails when threshold uncertainty is large, reductions in this uncertainty may bring about the behavioural change needed to avert a climate `catastrophe'. Here we present the results of an experiment, rooted in a game-theoretic model, showing that behaviour differs markedly either side of a dividing line for threshold uncertainty. On one side of the dividing line, where threshold uncertainty is relatively large, free riding proves irresistible and trust illusive, making it virtually inevitable that the tipping point will be crossed. On the other side, where threshold uncertainty is small, the incentive to coordinate is strong and trust more robust, often leading the players to avoid crossing the tipping point. Our results show that uncertainty must be reduced to this `good' side of the dividing line to stimulate the behavioural shift needed to avoid `dangerous' climate change.
Design, analysis, optimization and control of rotor tip flows
NASA Astrophysics Data System (ADS)
Maesschalck, Cis Guy M. De
Developments in turbomachinery focus on efficiency and reliability enhancements, while reducing the production costs. In spite of the many noteworthy experimental and numerical investigations over the past decades, the turbine tip design presents numerous challenges to the engine manufacturers, and remains the primary factor defining the machine durability for the periodic removal of the turbine components during overhaul. Due to the hot gases coming from the upstream combustion chamber, the turbine blades are subjected to temperatures far above the metal creep temperature, combined with severe thermal stresses induced within the blade material. Inadequate designs cause early tip burnouts leading to considerable performance degradations, or even a catastrophic turbine failure. Moreover, the leakage spillage, nowadays often exceeding the transonic regime, generates large aerodynamic penalties which are responsible for about one third of the turbine losses. In this view, the current doctoral research exploits the potential through the modification and optimization of the blade tip shape as a means to control the tip leakage flow aerodynamics and manage the heat load distribution over the blade profile to improve the turbine efficiency and durability. Three main design strategies for unshrouded turbine blade tips were analyzed and optimized: tight running clearances, blade tip contouring and the use of complex squealer-like geometries. The altered overtip flow physics and heat transfer characteristics were simulated for tight gap sizes as low as 0.5% down to 0.1% of the blade height, occurring during engine transients and soon to be expected due to recent developments in active clearance control strategies. The potential of fully 3D contoured blade top surfaces, allowing to adapt the profile locally to the changing flow conditions throughout the camberline, is quantified. First adopting a quasi-3D approach and subsequently using a full 3D optimization. For the industrial rub-safe squealer profiles featuring cavities separated by upstanding rims, a topology-like multi-objective 3D optimization strategy is used to identify so far undiscovered, optimal blade tip profiles. Furthermore, the additional potential of the widely adopted shroud coolant injection just upstream of the rotor blade is examined. Specifically, the possibility of combining the beneficial effect of the purge flow in the overtip region while minimizing the detrimental influence on the upper passage vortex is explored. Eventually, a high-speed rotating turbine facility at the von Karman Institute was redesigned, allowing simultaneous testing of multiple distinct blade (tip) profiles mounted in separate sectors around the rotor annulus. Important considerations related with the balancing and precise clearance design are highlighted, arising from the complexity of such rainbow-rotor configuration. Moreover, approaches are described to integrate Reynolds-Averaged Navier-Stokes simulations to a priori estimate the errors induced by the finite spatial sampling and inherent limited sensor bandwidth. This research effort provided new insights into the overtip flow topology and aerothermal characteristics, identified new design strategies to create future turbines with enhanced aerodynamic efficiencies and reduced thermal loads, and paved the way for an elaborate experimental validation in a rotating turbine facility, at engine-matched conditions.
Technical Subjects in Secondary Schools
ERIC Educational Resources Information Center
Howard, A. E.
2008-01-01
Purpose: This paper aims to examine technical education in various types of secondary schools, and suggests three levels of technical courses to be taught in secondary schools. Design/methodology/approach: The paper discusses the differences between technical schools and colleges, and vocational technical courses taught in "academic"…
Conceptual Design of a Two Spool Compressor for the NASA Large Civil Tilt Rotor Engine
NASA Technical Reports Server (NTRS)
Veres, Joseph P.; Thurman, Douglas R.
2010-01-01
This paper focuses on the conceptual design of a two spool compressor for the NASA Large Civil Tilt Rotor engine, which has a design-point pressure ratio goal of 30:1 and an inlet weight flow of 30.0 lbm/sec. The compressor notional design requirements of pressure ratio and low-pressure compressor (LPC) and high pressure ratio compressor (HPC) work split were based on a previous engine system study to meet the mission requirements of the NASA Subsonic Rotary Wing Projects Large Civil Tilt Rotor vehicle concept. Three mean line compressor design and flow analysis codes were utilized for the conceptual design of a two-spool compressor configuration. This study assesses the technical challenges of design for various compressor configuration options to meet the given engine cycle results. In the process of sizing, the technical challenges of the compressor became apparent as the aerodynamics were taken into consideration. Mechanical constraints were considered in the study such as maximum rotor tip speeds and conceptual sizing of rotor disks and shafts. The rotor clearance-to-span ratio in the last stage of the LPC is 1.5% and in the last stage of the HPC is 2.8%. Four different configurations to meet the HPC requirements were studied, ranging from a single stage centrifugal, two axi-centrifugals, and all axial stages. Challenges of the HPC design include the high temperature (1,560deg R) at the exit which could limit the maximum allowable peripheral tip speed for centrifugals, and is dependent on material selection. The mean line design also resulted in the definition of the flow path geometry of the axial and centrifugal compressor stages, rotor and stator vane angles, velocity components, and flow conditions at the leading and trailing edges of each blade row at the hub, mean and tip. A mean line compressor analysis code was used to estimate the compressor performance maps at off-design speeds and to determine the required variable geometry reset schedules of the inlet guide vane and variable stators that would result in the transonic stages being aerodynamically matched with high efficiency and acceptable stall margins based on user specified maximum levels of rotor diffusion factor and relative velocity ratio.
Ahn, J H; Kim, I S; Yang, J H; Lee, I G; Seo, D H; Kim, S P
2017-02-01
The lower superior vena cava (SVC), near its junction with the right atrium (RA), is considered the ideal location for the central venous catheter tip to ensure proper function and prevent injuries. We determined catheter insertion depth with a new formula using the sternoclavicular joint and the carina as radiological landmarks, with a 1.5 cm safety margin. The accuracy of tip positioning with the radiological landmark-based technique (R) and Peres' formula (P) was compared using transoesophageal echocardiography. Real-time ultrasound-guided central venous catheter insertion was done through the right internal jugular or subclavian vein. Patients were randomly assigned to either the P group (n=93) or the R group (n=95). Optimal catheter tip position was considered to be within 2 cm above and 1 cm below the RA-SVC junction. Catheter tip position, abutment, angle to the vascular wall, and flow stream were evaluated on a bicaval view. The distance from the skin insertion point to the RA-SVC junction and determined depth of catheter insertion were more strongly correlated in the R group [17.4 (1.2) and 16.7 (1.5) cm; r=0.821, P<0.001] than in the P group [17.3 (1.2) and 16.4 (1.1) cm; r=0.517, P<0.001], with z=3.96 (P<0.001). More tips were correctly positioned in the R group than in the P group (74 vs 93%, P=0.001). Abutment, tip angle to the lateral wall >40°, and disrupted flow stream were comparable. Catheter tip position was more accurate with a radiological landmark-based technique than with Peres' formula. Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp KCT0001937. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Kim, Se-Chan; Heinze, Ingo; Schmiedel, Alexandra; Baumgarten, Georg; Knuefermann, Pascal; Hoeft, Andreas; Weber, Stefan
2015-01-01
Visualisation of a central venous catheter (CVC) with ultrasound is restricted to the internal jugular vein (IJV). CVC tip position is confirmed by chest radiography, intracardiac ECG or transoesophageal/transthoracic echocardiography (TEE/TTE). We explored the feasibility, safety and accuracy of a right supraclavicular view for visualisation of the lower superior vena cava (SVC) and the right pulmonary artery (RPA) as an ultrasound landmark for real-time ultrasound-guided CVC tip positioning via the right IJV. Ultrasound was then compared with chest radiography. An observational pilot study. Bonn, University Hospital, Germany. From July to October 2012. Fifty-one patients scheduled for elective surgery. Reasons for exclusion were emergency procedure, thrombosis or small IJV lumen and mechanical obstacle to guidewire advancement. In 48 patients, CVC insertion via the right IJV and progress of the guidewire into the lower SVC were continuously guided by an ultrasound transducer in the right supraclavicular fossa. CVC tip position in lower SVC and tip-to-carina distance were assessed with chest radiography as a reference method and additionally with TEE in cardiothoracic patients. Insertion depth was compared with intracardiac ECG and body-height formula. The guidewire tip was seen in the SVC of all patients. In four patients, the tip was not visible in proximity of the RPA. Chest radiography and TEE confirmed CVC tip position in the lower SVC (zone A). Bland-Altman analysis revealed an average of difference of 1.6 cm for ultrasound versus ECG (95% limit of agreement -2 to 5 cm) and an average of difference of 1 cm for ultrasound versus body-height formula (95% limit of agreement -2 to 4 cm). Ultrasound via a right supraclavicular view is a feasible, well tolerated and accurate approach and should be further explored. Chest radiography confirmed CVC position in the lower SVC.
Combining the Cutting and Mulliken methods for primary repair of the bilateral cleft lip nose.
Morovic, Carmen Gloria; Cutting, Court
2005-11-01
Since 1990, primary bilateral cleft nasal reconstruction has been focused on placing the lower lateral cartilages into normal anatomical position. Of the four major techniques in this class, the Cutting (i.e., retrograde) method and the Mulliken method have been most successful. The retrograde method makes no external nasal incisions, but requires either preoperative or postoperative nasal molding to achieve maximum benefit. Mulliken's technique does not require molding, but leaves the footplates of the medial crura in the depression above the projecting premaxilla associated with the diminutive anterior nasal spine. Leaving the footplates in place also prevents adequate approximation of the alar bases. In this article, the two methods are combined to achieve the benefits of both. We report our experience with the retrograde nasal approach associated with marginal rim incisions (Mulliken method) in a series of 25 consecutive bilateral cleft lip cases simultaneous with lip repair. We performed a retrograde approach through membranous septum incisions elevating a prolabial-columellar flap. To facilitate alar cartilage manipulation we added bilateral marginal rim incisions. Nasal width, columella length and width, tip projection, and nasolabial angle were analyzed after a minimum of 2 years after surgery. These were compared with a normal, age-matched, control group. We also examined nostril symmetry and marginal nostril scars. Columellar length was not statistically significantly different from that of the control group (p = 0.122442). Nasal width, columellar width, tip projection, and nasolabial angle were all significantly greater in the cleft group than normal (p < 0.001). No hypertrophied scars were found associated with the marginal rim scar. Adding the Mulliken approach allows alar cartilage manipulation to be performed more easily than when using the retrograde approach alone. Tip projection and alar base narrowing are facilitated using the combined technique rather than the Mulliken approach alone. Prolabial flap manipulation is safe using this combined approach, even in cases with a severely projected premaxilla. We believe that the combined approach is safe and yields better long-term results than either technique alone.
A Geographic Approach to the Study of Natural Gas.
ERIC Educational Resources Information Center
Sheskin, Ira M.
1980-01-01
Provides information, tips, references, and materials to high school and college level geography teachers on developing a unit on natural gas. Data are presented in the form of tables, maps, figures, and textual analysis. (Author/DB)
A Hybrid Multi-Scale Model of Crystal Plasticity for Handling Stress Concentrations
Sun, Shang; Ramazani, Ali; Sundararaghavan, Veera
2017-09-04
Microstructural effects become important at regions of stress concentrators such as notches, cracks and contact surfaces. A multiscale model is presented that efficiently captures microstructural details at such critical regions. The approach is based on a multiresolution mesh that includes an explicit microstructure representation at critical regions where stresses are localized. At regions farther away from the stress concentration, a reduced order model that statistically captures the effect of the microstructure is employed. The statistical model is based on a finite element representation of the orientation distribution function (ODF). As an illustrative example, we have applied the multiscaling method tomore » compute the stress intensity factor K I around the crack tip in a wedge-opening load specimen. The approach is verified with an analytical solution within linear elasticity approximation and is then extended to allow modeling of microstructural effects on crack tip plasticity.« less
A Hybrid Multi-Scale Model of Crystal Plasticity for Handling Stress Concentrations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Shang; Ramazani, Ali; Sundararaghavan, Veera
Microstructural effects become important at regions of stress concentrators such as notches, cracks and contact surfaces. A multiscale model is presented that efficiently captures microstructural details at such critical regions. The approach is based on a multiresolution mesh that includes an explicit microstructure representation at critical regions where stresses are localized. At regions farther away from the stress concentration, a reduced order model that statistically captures the effect of the microstructure is employed. The statistical model is based on a finite element representation of the orientation distribution function (ODF). As an illustrative example, we have applied the multiscaling method tomore » compute the stress intensity factor K I around the crack tip in a wedge-opening load specimen. The approach is verified with an analytical solution within linear elasticity approximation and is then extended to allow modeling of microstructural effects on crack tip plasticity.« less
Determination of Fracture Parameters for Multiple Cracks of Laminated Composite Finite Plate
NASA Astrophysics Data System (ADS)
Srivastava, Amit Kumar; Arora, P. K.; Srivastava, Sharad Chandra; Kumar, Harish; Lohumi, M. K.
2018-04-01
A predictive method for estimation of stress state at zone of crack tip and assessment of remaining component lifetime depend on the stress intensity factor (SIF). This paper discusses the numerical approach for prediction of first ply failure load (FL), progressive failure load, SIF and critical SIF for multiple cracks configurations of laminated composite finite plate using finite element method (FEM). The Hashin and Chang failure criterion are incorporated in ABAQUS using subroutine approach user defined field variables (USDFLD) for prediction of progressive fracture response of laminated composite finite plate, which is not directly available in the software. A tensile experiment on laminated composite finite plate with stress concentration is performed to validate the numerically predicted subroutine results, shows excellent agreement. The typical results are presented to examine effect of changing the crack tip distance (S), crack offset distance (H), and stacking fiber angle (θ) on FL, and SIF .
Dynamics of cell wall elasticity pattern shapes the cell during yeast mating morphogenesis
Goldenbogen, Björn; Giese, Wolfgang; Hemmen, Marie; Uhlendorf, Jannis; Herrmann, Andreas
2016-01-01
The cell wall defines cell shape and maintains integrity of fungi and plants. When exposed to mating pheromone, Saccharomyces cerevisiae grows a mating projection and alters in morphology from spherical to shmoo form. Although structural and compositional alterations of the cell wall accompany shape transitions, their impact on cell wall elasticity is unknown. In a combined theoretical and experimental approach using finite-element modelling and atomic force microscopy (AFM), we investigated the influence of spatially and temporally varying material properties on mating morphogenesis. Time-resolved elasticity maps of shmooing yeast acquired with AFM in vivo revealed distinct patterns, with soft material at the emerging mating projection and stiff material at the tip. The observed cell wall softening in the protrusion region is necessary for the formation of the characteristic shmoo shape, and results in wider and longer mating projections. The approach is generally applicable to tip-growing fungi and plants cells. PMID:27605377
Design and Control of a Mechatronic Tracheostomy Tube for Automated Tracheal Suctioning.
Do, Thanh Nho; Seah, Tian En Timothy; Phee, Soo Jay
2016-06-01
Mechanical ventilation is required to aid patients with breathing difficulty to breathe more comfortably. A tracheostomy tube inserted through an opening in the patient neck into the trachea is connected to a ventilator for suctioning. Currently, nurses spend millions of person-hours yearly to perform this task. To save significant person-hours, an automated mechatronic tracheostomy system is needed. This system allows for relieving nurses and other carers from the millions of person-hours spent yearly on tracheal suctioning. In addition, it will result in huge healthcare cost savings. We introduce a novel mechatronic tracheostomy system including the development of a long suction catheter, automatic suctioning mechanisms, and relevant control approaches to perform tracheal suctioning automatically. To stop the catheter at a desired position, two approaches are introduced: 1) Based on the known travel length of the catheter tip; 2) Based on a new sensing device integrated at the catheter tip. It is known that backlash nonlinearity between the suction catheter and its conduit as well as in the gear system of the actuator are unavoidable. They cause difficulties to control the exact position of the catheter tip. For the former case, we develop an approximate model of backlash and a direct inverse scheme to enhance the system performances. The scheme does not require any complex inversions of the backlash model and allows easy implementations. For the latter case, a new sensing device integrated into the suction catheter tip is developed and backlash compensation controls are avoided. Automated suctioning validations are successfully carried out on the proposed experimental system. Comparisons and discussions are also introduced. The results demonstrate a significant contribution and potential benefits to the mechanical ventilation areas.
ERIC Educational Resources Information Center
Thakkar, Jitesh; Deshmukh, S. G.; Shastree, Anil
2006-01-01
Purpose: To explore the potential for adoption of TQM in self-financed technical institutions in the light of new demands and challenges posed by customers/students and society. Design/methodology/approach: The paper presents use of quality function deployment (QFD) which prioritizes technical requirements and correlates them with various…
Optimized technical and scientific design approach for high performance anticoincidence shields
NASA Astrophysics Data System (ADS)
Graue, Roland; Stuffler, Timo; Monzani, Franco; Bastia, Paolo; Gryksa, Werner; Pahl, Germit
2018-04-01
This paper, "Optimized technical and scientific design approach for high performance anticoincidence shields," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mark, H.
A development history and development status evaluation is presented for weapons technologies capable of serving as defenses against nuclear-tipped ballistic missiles. The decisive turning-point in this history was the March 23, 1983 announcement by President Reagan of the Strategic Defense Initiative (SDI). Due to President Reagan's emphasis on population protection, 'global' defense systems have tended to dominate SDI design efforts. The most important SDI technical achievements to date encompass (1) miniature homig devices, (2) the upgrade of the Patriot SAM for missile-interception capabilities, (3) light exoatmospheric projectiles, such as 'Brilliant Pebbles', (4) successful laser-communications experiments, and (5) the warhead/decoy-discriminating Firepondmore » lidar system. 7 refs.« less
Destruction of giant cluster-like vesicles by an ultrasonically activated device
NASA Astrophysics Data System (ADS)
Yahagi, Ryosuke; Yoshida, Kenji; Zhang, Yiting; Ebata, Masahiko; Toyota, Taro; Yamaguchi, Tadashi; Hayashi, Hideki
2016-07-01
In this paper, we propose a technically simple method of destroying a tissue marker composed of giant cluster-like vesicles (GCVs) to facilitate laparoscopic surgeries; the method releases various biological tracers contained in GCVs. An ultrasonically activated device (USAD) emitting 55.5 kHz ultrasound was employed for this purpose. Optical microscopy and fluorospectrophotometry revealed the destruction of GCVs after ultrasound irradiation when the blade tip was set 1.0 mm or closer to, but not directly in contact with, a GCV-containing cell. This means that USAD could be safely used for destroying this GCV tissue marker in clinical settings.
A synthetic peptide blocking TRPV1 activation inhibits UV-induced skin responses.
Kang, So Min; Han, Sangbum; Oh, Jang-Hee; Lee, Young Mee; Park, Chi-Hyun; Shin, Chang-Yup; Lee, Dong Hun; Chung, Jin Ho
2017-10-01
Transient receptor potential type 1 (TRPV1) can be activated by ultraviolet (UV) irradiation, and mediates UV-induced matrix metalloproteinase (MMP)-1 and proinflammatory cytokines in keratinocytes. Various chemicals and compounds targeting TRPV1 activation have been developed, but are not in clinical use mostly due to their safety issues. We aimed to develop a novel TRPV1-targeting peptide to inhibit UV-induced responses in human skin. We designed and generated a novel TRPV1 inhibitory peptide (TIP) which mimics the specific site in TRPV1 (aa 701-709: Gln-Arg-Ala-Ile-Thr-Ile-Leu-Asp-Thr, QRAITILDT), Thr 705 , and tested its efficacy of blocking UV-induced responses in HaCaT, mouse, and human skin. TIP effectively inhibited capsaicin-induced calcium influx and TRPV1 activation. Treatment of HaCaT with TIP prevented UV-induced increases of MMP-1 and pro-inflammatory cytokines such as interleukin (IL)-6 and tumor necrosis factor-α. In mouse skin in vivo, TIP inhibited UV-induced skin thickening and prevented UV-induced expression of MMP-13 and MMP-9. Moreover, TIP attenuated UV-induced erythema and the expression of MMP-1, MMP-2, IL-6, and IL-8 in human skin in vivo. The novel synthetic peptide targeting TRPV1 can ameliorate UV-induced skin responses in vitro and in vivo, providing a promising therapeutic approach against UV-induced inflammation and photoaging. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Park, Kyoung-Duck
Photon-induced phenomena in molecules and other materials play a significant role in device applications as well as understanding their physical properties. While a range of device applications using organic and inorganic molecules and soft and hard materials have led striking developments in modern technologies, using bulk systems has reached the limit in their functions, performance, and regarding application range. Recently, low-dimensional systems have emerged as appealing resources for the advanced technologies based on their significantly improved functions and properties. Hence, understanding light-matter interactions at their natural length scale is of fundamental significance, in addition to the next generation device applications. This thesis demonstrates a range of new functions and behaviors of low-dimensional materials revealed and controlled by the advanced tip-enhanced near-field spectroscopy and imaging techniques exceeding the current instrumental limits. To understand the behaviors of zero-dimensional (0D) molecular systems in interacting environments, we explore new regimes in tip-enhanced Raman spectroscopy (TERS) and scanning near-field optical microscopy (SNOM), revealing the fundamental nature of single-molecule dynamics and nanoscale spatial heterogeneity of biomolecules on the cell membranes. To gain insight into intramolecular properties and dynamic processes of single molecules, we use TERS at cryogenic temperatures. From temperature-dependent line narrowing and splitting, we investigate and quantify ultrafast vibrational dephasing, intramolecular coupling, and conformational heterogeneity. Through correlation analysis of fluctuations of individual modes, we observe rotational motion and spectral fluctuations of single-molecule. We extend single-molecule spectroscopy study into in situ nano-biomolecular imaging of cancer cells by developing in-liquid SNOM. We use a new mechanical resonance control, achieving a high-Q force sensing of the near-field probe. We reveal nanoscale correlations between surface biomolecules and intracellular organelle structures through near-field imaging of the spatial distribution of EGFRs on the membrane of A431 cancer cells. In addition, to understand modified spontaneous emission properties of single quantum dots coupled strongly with localized plasmon, we perform tip-enhanced photoluminescence (TEPL) spectroscopy of the single CdSe/ZnS quantum dots on gold film. We probe and control nanoscale processes in van der Waals two-dimensional (2D) materials. To understand lattice and electronic structure as well as elastic and phonon scattering properties of grain boundaries (GBs) in large-area graphene, we perform TERS imaging. Through correlated analysis of multispectral TERS images with corresponding topography and near-field scattering image, we reveal bilayer structure of GBs in the form of twisted stacking. In addition, we determine the misorientation angles of the bilayer GBs from a detailed quantitative investigation of the Raman modes. In addition, we present a new hybrid nano-optomechanical tip-enhanced spectroscopy and imaging approach combining TERS, TEPL, and atomic force local strain manipulation to probe the heterogeneous PL responses at nanoscale defects and control the local bandgap in transition metal dichalcogenide (TMD) monolayer. We further extend this approach to probe and control the radiative emission of dark excitons and localized excitons. Based on nano-tip enhanced spectroscopy with 600,000-fold PL enhancement induced by the plasmonic Purcell effect and few-fs radiative dynamics of the optical antenna tip, we can directly probe and actively modulate the dark exciton and localized exciton emissions in time ( ms) and space (<15 nm) at room temperature. Lastly, to extend the range of tip-enhanced microscopy applications to nano-crystallography and nonlinear optics, we present a generalizable approach controlling the excitation polarizability for both in-plane and out-of-plane vector fields by breaking the axial symmetry of a conventional Au tip. This vector field control with the tip enables probing of nonlinear optical second harmonic generation (SHG) responses from a range of ferroic materials as well as van der Waals 2D materials. Specifically, we demonstrate SHG nano-crystallography results for MoS2 monolayer film, ferroelectric YMnO3, BaTiO3-BiFeO3 multiferroics, and PbTiO3/SrTiO 3 superlattices.
Time to Talk: 6 Things To Know About Massage Therapy for Health Purposes
... that massage therapy may also promote relaxation and boost mood in people with cancer. A recent review ... mail More Tips 5 Things To Know About Mind and Body Approaches for Substance Use Disorders 6 ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kovoor-Misra, S.
Technical organizations are not only vulnerable to crises, but have the potential to create catastrophic crises. This has been devastatingly illustrated by recent crises, such as the gas leak in Bhopal, India, the Exxon Valdez oil spill, and the Challenger explosion. Thus, crises preparation for these organizations. This paper describes a Multidimensional Approach to crisis preparation for technical organizations. As part of this approach, come critical factors for crisis preparation are also described. The Multidimensional Approach is derived from the literature and a study of the crisis preparation of nine technical organizations. 28 refs., 3 figs., 4 tab.
Kato, Haruaki; Kobayashi, Shinya; Kawakami, Masako; Inoue, Hiroo; Iijima, Kazuyoshi; Nishizawa, Osamu
2004-10-01
Repair of a posterior urethral disruption associated with a pelvic fracture is a challenge for urologic surgeons. Here, we provide surgical and strategic tips to facilitate the delayed surgical repair of urethral distraction defects. Nine patients each with a traumatic posterior urethral distraction defect underwent delayed transperineal or transperineoabdominal bulboprostatic anastomosis. Four patients had previously undergone multiple procedures. Seven patients regained satisfactory urination without incontinence, although one other patient is suffering from incontinence. In one patient, urethral disruption occurred again after removal of the urethral catheter, and he is being managed by suprapubic catheter. In our experience, the key to success is to perform a true bulboprostatic mucosa-to-mucosa anastomosis without tension. For this purpose, a transperineoabdominal approach is of particular importance when the healthy mucosa of the prostatic apex cannot be revealed through a perineal approach due to dense fibrous scar or fractured bone. A partial pubectomy may be necessary according to the situation. By the transperineoabdominal approach, the scar tissue can be bypassed through a broad sub-pubic-arch tunnel, and a reliable anastomosis achieved.
Bloodless laparoscopic liver resection using radiofrequency thermal energy in the porcine model.
Tsalis, Konstantinos; Blouhos, Konstantinos; Vasiliadis, Konstantinos; Kalfadis, Stavros; Tsachalis, Theodoros; Savvas, Ioannis; Betsis, Dimitrios
2007-02-01
The aim of this study was to assess the feasibility and safety of laparoscopic hepatectomy using radiofrequency (RF) thermal energy in a porcine model. Fifteen female domestic pigs weighing 29.3 kg (range 25 to 35 kg) were used. Five transversal abdominal incisions (3 of 1 cm and 2 of 0.5 cm) were made for the introduction of the video camera and the other laparoscopic instruments. With the porta hepatis not clamped, the liver was inspected and the preferred lobe each time was divided using RF (cool-tip electrode 3 cm) with minimum bleeding. Serum liver enzymes and blood counts were drawn pre and postoperatively. All animals were killed after 1 week. The mean time of the procedures was 119 minutes (range 100 to 155 min). There were no intraoperative complications. Mean blood loss was 27 mL (range 5 to 60 mL), and the mass of the resected specimen was 132.5 g (range 65 to 305 g). There were no postoperative complications or deaths. Bloodless laparoscopic hepatectomy was technically feasible and safe in the porcine model using cool-tip electrode and 500-kHz RF Generator.
Technological innovation in video-assisted thoracic surgery.
Özyurtkan, Mehmet Oğuzhan; Kaba, Erkan; Toker, Alper
2017-01-01
The popularity of video-assisted thoracic surgery (VATS) which increased worldwide due to the recent innovations in thoracic surgical technics, equipment, electronic devices that carry light and vision and high definition monitors. Uniportal VATS (UVATS) is disseminated widely, creating a drive to develop new techniques and instruments, including new graspers and special staplers with more angulation capacities. During the history of VATS, the classical 10 mm 0° or 30° rigid rod lens system, has been replaced by new thoracoscopes providing a variable angle technology and allowing 0° and 120° range of vision. Besides, the tip of these novel thoracoscopes can be positioned away from the operating side minimize fencing with other thoracoscopic instruments. The curved-tip stapler technology, and better designed endostaplers helped better dissection, precision of control, more secure staple lines. UVATS also contributed to the development of embryonic natural orifice transluminal endoscopic surgery. Three-dimensional VATS systems facilitated faster and more accurate grasping, suturing, and dissection of the tissues by restoring natural 3D vision and the perception of depth. Another innovation in VATS is the energy-based coagulative and tissue fusion technology which may be an alternative to endostaplers.
A Large-eddy Simulation Study of Vertical Axis Wind Turbine Wakes in the Atmospheric Boundary Layer
NASA Astrophysics Data System (ADS)
Shamsoddin, Sina; Porté-Agel, Fernando
2016-04-01
Vertical axis wind turbines (VAWTs) offer some advantages over their horizontal axis counterparts, and are being considered as a viable alternative to conventional horizontal axis wind turbines (HAWTs). Nevertheless, a relative shortage of scientific, academic and technical investigations of VAWTs is observed in the wind energy community with respect to HAWTs. Having this in mind, in this work, we aim to study the wake of a single VAWT, placed in the atmospheric boundary layer, using large-eddy simulation (LES) coupled with actuator line model (ALM). It is noteworthy that this is the first time that such a study is being performed. To do this, for a typical 1 MW VAWT design, first, the variation of power coefficient with both the chord length of the blades and the tip-speed ratio is analyzed using LES-ALM, and an optimum combination of chord length and tip-speed ratio is obtained. Subsequently, the wake of a VAWT with these optimum specifications is thoroughly examined by showing different relevant mean and turbulent wake flow statistics. Keywords: vertical axis wind turbine (VAWT); VAWT wake; Atmospheric Boundary Layer (ABL); large eddy simulation (LES); actuator line model (ALM); turbulence.
Microshell-tipped optical fibers as sensors of high-pressure pulses in adverse environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benjamin, R.F.; Mayer, F.J.; Maynard, R.L.
1984-01-01
An optical-fiber sensor for detecting the arrival of strong pressure pulses was developed. The sensor consists of an optical fiber, tipped with a gas-filled microballoon. They have been used successfully in adverse environments including explosives, ballistics and electromagnetic pulses (EMP). The sensor produces a bright optical pulse caused by the rapid shock-heating of a gas, typically argon or xenon, which is confined in the spherical glass or plastic microballoon. The light pulse is transmitted via the optical fiber to a photo detector, usually a streak camera or photomultiplier tube. The microballoon optical sensor (called an optical pin by analogy tomore » standard electrical pins), was originally developed for diagnosing an explosive, pulsed-power generator. Optical pins are required due to the EMP. The optical pins are economical arrival-time indicators because many channels can be recorded by one streak camera. The generator tests and related experiments, involving projectile velocities and detonation velocities of several kilometers per sec have demonstrated the usefulness of the sensors in explosives and ballistics applications. The technical and cost advantages of this optical pin make it potentially useful for many electromagnetic, explosive, and ballistics applications.« less