Sample records for aquifer test analysis

  1. Hydraulic properties of the Madison aquifer system in the western Rapid City area, South Dakota

    USGS Publications Warehouse

    Greene, Earl A.

    1993-01-01

    Available information on hydrogeology, data from borehole geophysical logs, and aquifer tests were used to determine the hydraulic properties of the Madison aquifer. From aquifer-test analysis, transmissivity and storage coefficient were determined for the Minnelusa and Madison aquifers, and vertical hydraulic conductivity (Kv') along with specific storage (Ss') for the Minnelusa confining bed. Borehole geophysical well logs were used to determine the thickness and location of the Minnelusa aquifer, the lower Minnelusa confining bed, and the Madison aquifer within the Madison Limestone. Porosity values determined from quantitative analysis of borehole geophysical well logs were used in analyzing the aquifer-test data. The average porosity at the two aquifer-test sites is about 10 percent in the Minnelusa aquifer, 5 percent in the lower Minnelusa confining bed, and 35 percent in the Madison aquifer. The first aquifer test, which was conducted at Rapid City production well #6, produced measured drawdown in the Minnelusa and Madison aquifers. Neuman and Witherspoon's method of determining the hydraulic properties of leaky two-aquifer systems was used to evaluate the aquifer-test data by assuming the fracture and solution-opening network is equivalent to a porous media. Analysis of the aquifer test for the Minnelusa aquifer yielded a transmissivity value of 12,000 feet squared per day and a storage coefficient of 3 x 10-3. The specific storage of the Minnelusa confining bed was 2 x 10-7 per foot, and its vertical hydraulic conductivity was 0.3 foot per day. The transmissivity of the Madison aquifer at this site was 17,000 feet squared per day, and the storage coefficient was 2 x 10-3. The second aquifer test, which was conducted at Rapid City production well #5 (RC-5) produced measured drawdown only in the Madison aquifer. Hantush and Jacob's method of determining the hydraulic properties of leaky confined aquifers with no storage in the confining bed was used to evaluate the aquifer-test data by assuming the fracture and solution-opening network is equivalent to a porous media. The analysis of data from the RC-5 aquifer test showed that transmissivity was not equal in all directions. Hantush's method was used to determine the direction of radial anisotropy and magnitude of the major and minor axes of transmissivity. The major axis of transmissivity is at an angle of 42? east of north, and the transmissivity along this axis is about 56,000 feet squared per day. The minor axis of transmissivity is at an angle of 48? west of north, and the transmissivity along this axis is about 1,300 feet squared per day. The major axis of transmissivity intersects Cleghorn Springs, a large resurgent spring on the west edge of Rapid City. The shape of the potentiometric contours of the Madison aquifer near RC-5 agree with the orientation of the transmissivity ellipse. The average value of the storage coefficient from the isotropic analysis of the aquifer-test data was 3.5 x 10-4, and the average vertical hydraulic conductivity of the lower Minnelusa confining bed was 9.6 x 10-3 foot per day.

  2. Effects of Barometric Fluctuations on Well Water-Level Measurements and Aquifer Test Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spane, Frank A.

    1999-12-16

    This report examines the effects of barometric fluctuations on well water-level measurements and evaluates adjustment and removal methods for determining areal aquifer head conditions and aquifer test analysis. Two examples of Hanford Site unconfined aquifer tests are examined that demonstrate baro-metric response analysis and illustrate the predictive/removal capabilities of various methods for well water-level and aquifer total head values. Good predictive/removal characteristics were demonstrated with best corrective results provided by multiple-regression deconvolution methods.

  3. Comparison of aquifer characteristics derived from local and regional aquifer tests.

    USGS Publications Warehouse

    Randolph, R.B.; Krause, R.E.; Maslia, M.L.

    1985-01-01

    A comparison of the aquifer parameter values obtained through the analysis of a local and a regional aquifer test involving the same area in southeast Georgia is made in order to evaluate the validity of extrapolating local aquifer-test results for use in large-scale flow simulations. Time-drawdown and time-recovery data were analyzed by using both graphical and least-squares fitting of the data to the Theis curve. Additionally, directional transmissivity, transmissivity tensor, and angle of anisotropy were computed for both tests. -from Authors Georgia drawdown transmissivity regional aquifer tests

  4. Summary and evaluation of hydraulic property data available for the Hanford Site upper basalt confined aquifer system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spane, F.A. Jr.; Vermeul, V.R.

    Pacific Northwest Laboratory, as part of the Hanford Site Ground-Water Surveillance Project, examines the potential for offsite migration of contamination within the upper basalt confined aquifer system. For the past 40 years, hydrologic testing of the upper basalt confined aquifer has been conducted by a number of Hanford Site programs. Hydraulic property estimates are important for evaluating aquifer flow characteristics (i.e., ground-water flow patterns, flow velocity, transport travel time). Presented are the first comprehensive Hanford Site-wide summary of hydraulic properties for the upper basalt confined aquifer system (i.e., the upper Saddle Mountains Basalt). Available hydrologic test data were reevaluated usingmore » recently developed diagnostic test analysis methods. A comparison of calculated transmissivity estimates indicates that, for most test results, a general correspondence within a factor of two between reanalysis and previously reported test values was obtained. For a majority of the tests, previously reported values are greater than reanalysis estimates. This overestimation is attributed to a number of factors, including, in many cases, a misapplication of nonleaky confined aquifer analysis methods in previous analysis reports to tests that exhibit leaky confined aquifer response behavior. Results of the test analyses indicate a similar range for transmissivity values for the various hydro-geologic units making up the upper basalt confined aquifer. Approximately 90% of the calculated transmissivity values for upper basalt confined aquifer hydrogeologic units occur within the range of 10{sup 0} to 10{sup 2} m{sup 2}/d, with 65% of the calculated estimate values occurring between 10{sup 1} to 10{sup 2} m{sup 2}d. These summary findings are consistent with the general range of values previously reported for basalt interflow contact zones and sedimentary interbeds within the Saddle Mountains Basalt.« less

  5. Information content of slug tests for estimating hydraulic properties in realistic, high-conductivity aquifer scenarios

    NASA Astrophysics Data System (ADS)

    Cardiff, Michael; Barrash, Warren; Thoma, Michael; Malama, Bwalya

    2011-06-01

    SummaryA recently developed unified model for partially-penetrating slug tests in unconfined aquifers ( Malama et al., in press) provides a semi-analytical solution for aquifer response at the wellbore in the presence of inertial effects and wellbore skin, and is able to model the full range of responses from overdamped/monotonic to underdamped/oscillatory. While the model provides a unifying framework for realistically analyzing slug tests in aquifers (with the ultimate goal of determining aquifer properties such as hydraulic conductivity K and specific storage Ss), it is currently unclear whether parameters of this model can be well-identified without significant prior information and, thus, what degree of information content can be expected from such slug tests. In this paper, we examine the information content of slug tests in realistic field scenarios with respect to estimating aquifer properties, through analysis of both numerical experiments and field datasets. First, through numerical experiments using Markov Chain Monte Carlo methods for gauging parameter uncertainty and identifiability, we find that: (1) as noted by previous researchers, estimation of aquifer storage parameters using slug test data is highly unreliable and subject to significant uncertainty; (2) joint estimation of aquifer and skin parameters contributes to significant uncertainty in both unless prior knowledge is available; and (3) similarly, without prior information joint estimation of both aquifer radial and vertical conductivity may be unreliable. These results have significant implications for the types of information that must be collected prior to slug test analysis in order to obtain reliable aquifer parameter estimates. For example, plausible estimates of aquifer anisotropy ratios and bounds on wellbore skin K should be obtained, if possible, a priori. Secondly, through analysis of field data - consisting of over 2500 records from partially-penetrating slug tests in a heterogeneous, highly conductive aquifer, we present some general findings that have applicability to slug testing. In particular, we find that aquifer hydraulic conductivity estimates obtained from larger slug heights tend to be lower on average (presumably due to non-linear wellbore losses) and tend to be less variable (presumably due to averaging over larger support volumes), supporting the notion that using the smallest slug heights possible to produce measurable water level changes is an important strategy when mapping aquifer heterogeneity. Finally, we present results specific to characterization of the aquifer at the Boise Hydrogeophysical Research Site. Specifically, we note that (1) K estimates obtained using a range of different slug heights give similar results, generally within ±20%; (2) correlations between estimated K profiles with depth at closely-spaced wells suggest that K values obtained from slug tests are representative of actual aquifer heterogeneity and not overly affected by near-well media disturbance (i.e., "skin"); (3) geostatistical analysis of K values obtained indicates reasonable correlation lengths for sediments of this type; and (4) overall, K values obtained do not appear to correlate well with porosity data from previous studies.

  6. Flow Generated by a Partially Penetrating Well in a Leaky Two-Aquifer System with a Storative Semiconfining Layer

    NASA Astrophysics Data System (ADS)

    Sepulveda, N.; Rohrer, K.

    2008-05-01

    The permeability of the semiconfining layers of the highly productive Floridan Aquifer System may be large enough to invalidate the assumptions of the leaky aquifer theory. These layers are the intermediate confining and the middle semiconfining units. The analysis of aquifer-test data with analytical solutions of the ground-water flow equation developed with the approximation of a low hydraulic conductivity ratio between the semiconfining layer and the aquifer may lead to inaccurate hydraulic parameters. An analytical solution is presented here for the flow in a confined leaky aquifer, the overlying storative semiconfining layer, and the unconfined aquifer, generated by a partially penetrating well in a two-aquifer system, and allowing vertical and lateral flow components to occur in the semiconfining layer. The equations describing flow caused by a partially penetrating production well are solved analytically to provide a method to accurately determine the hydraulic parameters in the confined aquifer, semiconfining layer, and unconfined aquifer from aquifer-test data. Analysis of the drawdown data from an aquifer test performed in central Florida showed that the flow solution presented here for the semiconfining layer provides a better match and a more unique identification of the hydraulic parameters than an analytical solution that considers only vertical flow in the semiconfining layer.

  7. Documentation of spreadsheets for the analysis of aquifer-test and slug-test data

    USGS Publications Warehouse

    Halford, Keith J.; Kuniansky, Eve L.

    2002-01-01

    Several spreadsheets have been developed for the analysis of aquifer-test and slug-test data. Each spreadsheet incorporates analytical solution(s) of the partial differential equation for ground-water flow to a well for a specific type of condition or aquifer. The derivations of the analytical solutions were previously published. Thus, this report abbreviates the theoretical discussion, but includes practical information about each method and the important assumptions for the applications of each method. These spreadsheets were written in Microsoft Excel 9.0 (use of trade names does not constitute endorsement by the USGS). Storage properties should not be estimated with many of the spreadsheets because most are for analyzing single-well tests. Estimation of storage properties from single-well tests is generally discouraged because single-well tests are affected by wellbore storage and by well construction. These non-ideal effects frequently cause estimates of storage to be erroneous by orders of magnitude. Additionally, single-well tests are not sensitive to aquifer-storage properties. Single-well tests include all slug tests (Bouwer and Rice Method, Cooper, Bredehoeft, Papadopulos Method, and van der Kamp Method), the Cooper-Jacob straight-line Method, Theis recovery-data analysis, Jacob-Lohman method for flowing wells in a confined aquifer, and the step-drawdown test. Multi-well test spreadsheets included in this report are; Hantush-Jacob Leaky Aquifer Method and Distance-Drawdown Methods. The distance-drawdown method is an equilibrium or steady-state method, thus storage cannot be estimated.

  8. A computer program (MACPUMP) for interactive aquifer-test analysis

    USGS Publications Warehouse

    Day-Lewis, F. D.; Person, M.A.; Konikow, Leonard F.

    1995-01-01

    This report introduces MACPUMP (Version 1.0), an aquifer-test-analysis package for use with Macintosh4 computers. The report outlines the input- data format, describes the solutions encoded in the program, explains the menu-items, and offers a tutorial illustrating the use of the program. The package reads list-directed aquifer-test data from a file, plots the data to the screen, generates and plots type curves for several different test conditions, and allows mouse-controlled curve matching. MACPUMP features pull-down menus, a simple text viewer for displaying data-files, and optional on-line help windows. This version includes the analytical solutions for nonleaky and leaky confined aquifers, using both type curves and straight-line methods, and for the analysis of single-well slug tests using type curves. An executable version of the code and sample input data sets are included on an accompanying floppy disk.

  9. Integrating borehole logs and aquifer tests in aquifer characterization

    USGS Publications Warehouse

    Paillet, Frederick L.; Reese, R.S.

    2000-01-01

    Integration of lithologic logs, geophysical logs, and hydraulic tests is critical in characterizing heterogeneous aquifers. Typically only a limited number of aquifer tests can be performed, and these need to be designed to provide hydraulic properties for the principle aquifers in the system. This study describes the integration of logs and aquifer tests in the development of a hydrostratigraphic model for the surficial aquifer system in and around Big Cypress National Preserve in eastern Collier County, Florida. Borehole flowmeter tests provide qualitative permeability profiles in most of 26 boreholes drilled in the Study area. Flow logs indicate the depth of transmissive units, which are correlated across the study area. Comparison to published studies in adjacent areas indicates that the main limestone aquifer of the 000000Tamiami Formation in the study area corresponds with the gray limestone aquifer in western Dade County and the water table and lower Tamiami Aquifer in western Collier County. Four strategically located, multiwell aquifer tests are used to quantify the qualitative permeability profiles provided by the flowmeter log analysis. The hydrostratigraphic model based on these results defines the main aquifer in the central part of the study area as unconfined to semiconfined with a transmissivity as high as 30,000 m2/day. The aquifer decreases in transmissivity to less than 10,000 m2/day in some parts of western Collier County, and becomes confined to the east and northeast of the study area, where transmissivity decreases to below 5000 m2/day.Integration of lithologic logs, geophysical logs, and hydraulic tests is critical in characterizing heterogeneous aquifers. Typically only a limited number of aquifer tests can be performed, and these need to be designed to provide hydraulic properties for the principle aquifers in the system. This study describes the integration of logs and aquifer tests in the development of a hydrostratigraphic model for the surficial aquifer system in and around Big Cypress National Preserve in eastern Collier County, Florida. Borehole flowmeter tests provide qualitative permeability profiles in most of 26 boreholes drilled in the study area. Flow logs indicate the depth of transmissive units, which are correlated across the study area. Comparison to published studies in adjacent areas indicates that the main limestone aquifer of the Tamiami Formation in the study area corresponds with the gray limestone aquifer in western Dade County and the water table and lower Tamiami Aquifer in western Collier County. Four strategically located, multiwell aquifer tests are used to quantify the qualitative permeability profiles provided by the flowmeter log analysis. The hydrostratigraphic model based on these results defines the main aquifer in the central part of the study area as unconfined to semiconfined with a transmissivity as high as 30,000 m2/day. The aquifer decreases in transmissivity to less than 10,000 m2/day in some parts of western Collier County, and becomes confined to the east and northeast of the study area, where transmissivity decreases to below 5000 m2/day.

  10. Qtracer Program for Tracer-Breakthrough Curve Analysis for Karst and Fractured-Rock Aquifers (2000)

    EPA Science Inventory

    Tracer tests are generally regarded as being the most reliable and efficient means of gathering subsurface hydraulic information. This is true for all types of aquifers, but especially so for karst and fractured-rock aquifers. Qualitative tracing tests have been conventionally em...

  11. Hydrogeology and results of aquifer tests in the vicinity of a hazardous-waste disposal site near Byron, Illinois

    USGS Publications Warehouse

    Kay, Robert T.; Olson, David N.; Ryan, Barbara J.

    1989-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Environmental Protection Agency, conducted an investigation of a Superfund Site near Byron, Illinois. The purpose of the investigation was to determine the hydrogeologic properties of the Galena-Platteville and St. Peter aquifers, the primary water-supply aquifers for domestic supply in the area. The Galena and Platteville Groups and older St. Peter Sandstone are separated by the Harmony Hill Shale Member of the Glenwood Formation. The Harmony Hill Shale Member is a semiconfining unit. Groundwater flow in the study area is from the site northwestward to the Rock River. Movement of groundwater in the dolomites is mainly through joints, fractures, and solution openings. Analysis of the Galena-Platteville aquifer-test data indicates that the calculated aquifer transmissivity ranges from 490 to 670 sq ft/day, and the calculated specific yield ranges from 0.017 to 0.140. Aquifer test data also indicate that the Galena-Platteville aquifer is heterogeneous and anisotropic. Analysis of the St. Peter aquifer-test data indicates that the calculated transmissivity of the aquifer ranges from 1,200 to 1 ,305 sq ft/day, storativity ranges from 0.000528 to 0.00128, horizontal hydraulic conductivity ranges from 2.9 to 3.1 ft/day, and leakage through the Harmony Hill Shale Member ranges from .000123 to .000217 ft/day/ft. (USGS)

  12. Analysis of pumping tests: Significance of well diameter, partial penetration, and noise

    USGS Publications Warehouse

    Heidari, M.; Ghiassi, K.; Mehnert, E.

    1999-01-01

    The nonlinear least squares (NLS) method was applied to pumping and recovery aquifer test data in confined and unconfined aquifers with finite diameter and partially penetrating pumping wells, and with partially penetrating piezometers or observation wells. It was demonstrated that noiseless and moderately noisy drawdown data from observation points located less than two saturated thicknesses of the aquifer from the pumping well produced an exact or acceptable set of parameters when the diameter of the pumping well was included in the analysis. The accuracy of the estimated parameters, particularly that of specific storage, decreased with increases in the noise level in the observed drawdown data. With consideration of the well radii, the noiseless drawdown data from the pumping well in an unconfined aquifer produced good estimates of horizontal and vertical hydraulic conductivities and specific yield, but the estimated specific storage was unacceptable. When noisy data from the pumping well were used, an acceptable set of parameters was not obtained. Further experiments with noisy drawdown data in an unconfined aquifer revealed that when the well diameter was included in the analysis, hydraulic conductivity, specific yield and vertical hydraulic conductivity may be estimated rather effectively from piezometers located over a range of distances from the pumping well. Estimation of specific storage became less reliable for piezemeters located at distances greater than the initial saturated thickness of the aquifer. Application of the NLS to field pumping and recovery data from a confined aquifer showed that the estimated parameters from the two tests were in good agreement only when the well diameter was included in the analysis. Without consideration of well radii, the estimated values of hydraulic conductivity from the pumping and recovery tests were off by a factor of four.The nonlinear least squares method was applied to pumping and recovery aquifer test data in confined and unconfined aquifers with finite diameter and partially penetrating piezometers and observation wells. Noiseless and moderately noisy drawdown data from observation points located less than two saturated thicknesses of the aquifer from the pumping well produced a set of parameters that agrees very well with piezometer test data when the diameter of the pumping well was included in the analysis. The accuracy of the estimated parameters decreased with increasing noise level.

  13. Analysis of hydrogeologic properties in the Prairie du Chien-Jordan aquifer, Shakopee Mdewakanton Sioux Community, southeastern Minnesota

    USGS Publications Warehouse

    Strobel, M.L.; Delin, G.N.

    1996-01-01

    The Neuman (1974) method for unconfined aquifers was used to analyze data collected from the two observation wells during the drawdown and recovery periods, resulting in a range of estimated aquifer hydraulic properties. Aquifer transmissivity ranged from 4,710 to 7,660 ft2/d and aquifer storativity ranged from 8.24 x 10-5 to 1.60 x 10-4. These values are generally in close agreement for all four sets of data, given the limitations of the test, indicating that the test results are accurate and representative of the aquifer hydrogeologic properties. The lack of late-time data made it impossible to accurately assess aquifer specific yield.

  14. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... withdraw or increase a withdrawal of groundwater shall perform a constant-rate aquifer test in accordance... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence...

  15. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... withdraw or increase a withdrawal of groundwater shall perform a constant-rate aquifer test in accordance... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence...

  16. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... withdraw or increase a withdrawal of groundwater shall perform a constant-rate aquifer test in accordance... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence...

  17. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... withdraw or increase a withdrawal of groundwater shall perform a constant-rate aquifer test in accordance... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence...

  18. Fracture trace map and single-well aquifer test results in a carbonate aquifer in Berkeley County, West Virginia

    USGS Publications Warehouse

    McCoy, Kurt J.; Podwysocki, Melvin H.; Crider, E. Allen; Weary, David J.

    2005-01-01

    These data contain information on the results of single-well aquifer tests, lineament analysis, and a bedrock geologic map compilation for the low-lying carbonate and shale areas of eastern Berkeley County, West Virginia. Efforts have been initiated by management agencies of Berkeley County in cooperation with the U.S. Geological Survey to further the understanding of the spatial distribution of fractures in the carbonate regions and their correlation with aquifer properties. This report presents transmissivity values from about 200 single-well aquifer tests and a map of fracture-traces determined from aerial photos and field investigations. Transmissivity values were compared to geologic factors possibly affecting its magnitude.

  19. Hydrogeologic and hydraulic characterization of aquifer and nonaquifer layers in a lateritic terrain (West Bengal, India)

    NASA Astrophysics Data System (ADS)

    Biswal, Sabinaya; Jha, Madan K.; Sharma, Shashi P.

    2018-02-01

    The hydrogeologic and hydraulic characteristics of a lateritic terrain in West Bengal, India, were investigated. Test drilling was conducted at ten sites and grain-size distribution curves (GSDCs) were prepared for 275 geologic samples. Performance evaluation of eight grain-size-analysis (GSA) methods was carried out to estimate the hydraulic conductivity (K) of subsurface formations. Finally, the GSA results were validated against pumping-test data. The GSDCs indicated that shallow aquifer layers are coarser than the deeper aquifer layers (uniformity coefficient 0.19-11.4). Stratigraphy analysis revealed that both shallow and deep aquifers of varying thickness exist at depths 9-40 and 40-79 m, respectively. The mean K estimates by the GSA methods are 3.62-292.86 m/day for shallow aquifer layers and 0.97-209.93 m/day for the deeper aquifer layers, suggesting significant aquifer heterogeneity. Pumping-test data indicated that the deeper aquifers are leaky confined with transmissivity 122.69-693.79 m2/day, storage coefficient 1.01 × 10-7-2.13 × 10-4 and leakance 2.01 × 10-7-34.56 × 10-2 day-1. Although the K values yielded by the GSA methods are generally larger than those obtained from the pumping tests, the Slichter, Harleman and US Bureau Reclamation (USBR) GSA methods yielded reasonable values at most of the sites (1-3 times higher than K estimates by the pumping-test method). In conclusion, more reliable aquifers exist at deeper depths that can be tapped for dependable water supply. GSA methods such as Slichter, Harleman and USBR can be used for the preliminary assessment of K in lateritic terrains in the absence of reliable field methods.

  20. Aquifer test interpretation using derivative analysis and diagnostic plots

    NASA Astrophysics Data System (ADS)

    Hernández-Espriú, Antonio; Real-Rangel, Roberto; Cortés-Salazar, Iván; Castro-Herrera, Israel; Luna-Izazaga, Gabriela; Sánchez-León, Emilio

    2017-04-01

    Pumping tests remain a method of choice to deduce fundamental aquifer properties and to assess well condition. In the oil and gas (O&G) industry, well testing has been the core technique in examining reservoir behavior over the last 50 years. The pressure derivative by Bourdet, it is perhaps, the most significant single development in the history of well test analysis. Recently, the so-called diagnostics plots (e.g. drawdown and drawdown derivative in a log-log plot) have been successfully tested in aquifers. However, this procedure is still underutilized by groundwater professionals. This research illustrates the applicability range, advantages and drawbacks (e.g. smoothing procedures) of diagnostic plots using field examples from a wide spectrum of tests (short/long tests, constant/variable flow rates, drawdown/buildup stages, pumping well/observation well) in dissimilar geological conditions. We analyze new and pre-existent aquifer tests in Mexico, USA, Canada, Germany, France and Saudi Arabia. In constant flow rate tests, our results show that derivative analysis is an easy, robust and powerful tool to assess near-borehole damage effects, formation heterogeneity, boundaries, flow regimes, infinite-acting radial stages, i.e., valid Theisian framework, and fracture-driven flow. In step tests, the effectiveness relies on high-frequency drawdown measurements. Moreover, we adapt O&G analytical solutions to cater for the conditions in groundwater systems. In this context, further parameters can be computed analytically from the plots, such as skin factor, head losses, wellbore storage, distance to the boundary, channel-aquifer and/or fracture zone width, among others. Therefore, diagnostic plots should be considered a mandatory tool for pumping tests analysis among hydrogeologists. This project has been supported by DGAPA (UNAM) under the research project PAPIIT IN-112815.

  1. Groundwater-level analysis of selected wells in the Hoosic River Valley near Hoosick Falls, New York, for aquifer framework and properties

    USGS Publications Warehouse

    Williams, John H.; Heisig, Paul M.

    2018-03-05

    The U.S. Geological Survey, in cooperation with the New York State Department of Environmental Conservation, analyzed groundwater levels, drilling record logs, and field water-quality data from selected wells, and the surficial geology in the Hoosic River valley south of the village of Hoosick Falls, New York, to provide information about the framework and properties of a confined aquifer. The aquifer, which consists of ice-contact sand and gravel overlain by lacustrine clay and silt, was evaluated by the New York State Department of Environmental Conservation as part of their investigation of alternate water supplies for the village whose wellfield has been affected by perfluorooctanoic acid. Wells inventoried in the study area were classified as confined, water table, or transitional between the two aquifer conditions. Groundwater levels in three confined-aquifer wells and a transitional-aquifer well responded to pumping of a test production well finished in the confined aquifer. Groundwater levels in a water-table well showed no detectable water-level change in response to test-well pumping. Analysis of drawdown and recovery data from the three confined-aquifer wells and a transitional-aquifer well through the application of the Theis type-curve method provided estimates of aquifer properties. Representation of a constant-head boundary in the analysis where an unnamed pond and fluvial-terrace deposits abut the valley wall resulted in satisfactory matches of the Theis type curves with the observed water-level responses. Aquifer transmissivity estimates ranged from 1,160 to 1,370 feet squared per day. Aquifer storativity estimates ranged from 5.2×10–5 to 1.1×10–3 and were consistent with the inferred degree of confinement and distance from the represented recharge boundary.

  2. Testing of stack-unit/aquifer sensitivity analysis using contaminant plume distribution in the subsurface of Savannah River Site, South Carolina, USA

    USGS Publications Warehouse

    Rine, J.M.; Shafer, J.M.; Covington, E.; Berg, R.C.

    2006-01-01

    Published information on the correlation and field-testing of the technique of stack-unit/aquifer sensitivity mapping with documented subsurface contaminant plumes is rare. The inherent characteristic of stack-unit mapping, which makes it a superior technique to other analyses that amalgamate data, is the ability to deconstruct the sensitivity analysis on a unit-by-unit basis. An aquifer sensitivity map, delineating the relative sensitivity of the Crouch Branch aquifer of the Administrative/Manufacturing Area (A/M) at the Savannah River Site (SRS) in South Carolina, USA, incorporates six hydrostratigraphic units, surface soil units, and relevant hydrologic data. When this sensitivity map is compared with the distribution of the contaminant tetrachloroethylene (PCE), PCE is present within the Crouch Branch aquifer within an area classified as highly sensitive, even though the PCE was primarily released on the ground surface within areas classified with low aquifer sensitivity. This phenomenon is explained through analysis of the aquifer sensitivity map, the groundwater potentiometric surface maps, and the plume distributions within the area on a unit-by- unit basis. The results of this correlation show how the paths of the PCE plume are influenced by both the geology and the groundwater flow. ?? Springer-Verlag 2006.

  3. Combined use of field and laboratory testing to predict preferred flow paths in an heterogeneous aquifer.

    PubMed

    Gierczak, R F D; Devlin, J F; Rudolph, D L

    2006-01-05

    Elevated nitrate concentrations within a municipal water supply aquifer led to pilot testing of a field-scale, in situ denitrification technology based on carbon substrate injections. In advance of the pilot test, detailed characterization of the site was undertaken. The aquifer consisted of complex, discontinuous and interstratified silt, sand and gravel units, similar to other well studied aquifers of glaciofluvial origin, 15-40 m deep. Laboratory and field tests, including a conservative tracer test, a pumping test, a borehole flowmeter test, grain-size analysis of drill cuttings and core material, and permeameter testing performed on core samples, were performed on the most productive depth range (27-40 m), and the results were compared. The velocity profiles derived from the tracer tests served as the basis for comparison with other methods. The spatial variation in K, based on grain-size analysis, using the Hazen method, were poorly correlated with the breakthrough data. Trends in relative hydraulic conductivity (K/K(avg)) from permeameter testing compared somewhat better. However, the trends in transient drawdown with depth, measured in multilevel sampling points, corresponded particularly well with those of solute mass flux. Estimates of absolute K, based on standard pumping test analysis of the multilevel drawdown data, were inversely correlated with the tracer test data. The inverse nature of the correlation was attributed to assumptions in the transient drawdown packages that were inconsistent with the variable diffusivities encountered at the scale of the measurements. Collectively, the data showed that despite a relatively low variability in K within the aquifer under study (within a factor of 3), water and solute mass fluxes were concentrated in discrete intervals that could be targeted for later bioremediation.

  4. The diagnostic plot analysis of artesian aquifers with case studies in Table Mountain Group of South Africa

    NASA Astrophysics Data System (ADS)

    Sun, Xiaobin; Xu, Yongxin; Lin, Lixiang

    2015-05-01

    Parameter estimates of artesian aquifers where piezometric head is above ground level are largely made through free-flowing and recovery tests. The straight-line method proposed by Jacob-Lohman is often used for interpretation of flow rate measured at flowing artesian boreholes. However, the approach fails to interpret the free-flowing test data from two artesian boreholes in the fractured-rock aquifer in Table Mountain Group (TMG) of South Africa. The diagnostic plot method using the reciprocal rate derivative is adapted to evaluate the artesian aquifer properties. The variation of the derivative helps not only identify flow regimes and discern the boundary conditions, but also facilitates conceptualization of the aquifer system and selection of an appropriate model for data interpretation later on. Test data from two free-flowing tests conducted in different sites in TMG are analysed using the diagnostic plot method. Based on the results, conceptual models and appropriate approaches are developed to evaluate the aquifer properties. The advantages and limitations of using the diagnostic plot method on free-flowing test data are discussed.

  5. The Qtracer2 Program for Tracer-Breakthrough Curve Analysis for Tracer Tests in Karstic Aquifers and Other Hydrologic Systems (2002)

    EPA Science Inventory

    Tracer testing is generally regarded as the most reliable and efficient method of gathering surface and subsurface hydraulic information. This is especially true for karstic and fractured-rock aquifers. Qualitative tracing tests have been conventionally employed in most karst s...

  6. Quasi-steady state conditions in heterogeneous aquifers during pumping tests

    NASA Astrophysics Data System (ADS)

    Zha, Yuanyuan; Yeh, Tian-Chyi J.; Shi, Liangsheng; Huang, Shao-Yang; Wang, Wenke; Wen, Jet-Chau

    2017-08-01

    Classical Thiem's well hydraulic theory, other aquifer test analyses, and flow modeling efforts often assume the existence of ;quasi-steady; state conditions. That is, while drawdowns due to pumping continue to grow, the hydraulic gradient in the vicinity of the pumping well does not change significantly. These conditions have built upon two-dimensional and equivalent homogeneous conceptual models, but few field data have been available to affirm the existence of these conditions. Moreover, effects of heterogeneity and three-dimensional flow on this quasi-steady state concept have not been thoroughly investigated and discussed before. In this study, we first present a quantitative definition of quasi-steady state (or steady-shape conditions) and steady state conditions based on the analytical solution of two- or three-dimensional flow induced by pumping in unbounded, homogeneous aquifers. Afterward, we use a stochastic analysis to investigate the influence of heterogeneity on the quasi-steady state concept in heterogeneous aquifers. The results of the analysis indicate that the time to reach an approximate quasi-steady state in a heterogeneous aquifer could be quite different from that estimated based on a homogeneous model. We find that heterogeneity of aquifer properties, especially hydraulic conductivity, impedes the development of the quasi-steady state condition before the flow reaching steady state. Finally, 280 drawdown-time data from the hydraulic tomographic survey conducted at a field site corroborate our finding that the quasi-steady state condition likely would not take place in heterogeneous aquifers unless pumping tests last a long period. Research significance (1) Approximate quasi-steady and steady state conditions are defined for two- or three-dimensional flow induced by pumping in unbounded, equivalent homogeneous aquifers. (2) Analysis demonstrates effects of boundary condition, well screen interval, and heterogeneity of parameters on the existence of the quasi-steady, and validity of approximate quasi-steady concept. (3) Temporal evaluation of information content about heterogeneity in head observations are analyzed in heterogeneous aquifer. (4) 280 observed drawdown-time data corroborate the stochastic analysis that quasi-steady is difficult to reach in highly heterogeneous aquifers.

  7. Three-Dimensional Flow Generated by a Partially Penetrating Well in a Two-Aquifer System

    NASA Astrophysics Data System (ADS)

    Sepulveda, N.

    2007-12-01

    An analytical solution is presented for three-dimensional (3D) flow in a confined aquifer and the overlying storative semiconfining layer and unconfined aquifer. The equation describing flow caused by a partially penetrating production well is solved analytically to provide a method to accurately determine the hydraulic parameters in the confined aquifer, semiconfining layer, and unconfined aquifer from aquifer-test data. Previous solutions for a partially penetrating well did not account for 3D flow or storativity in the semiconfining unit. The 3D and two- dimensional (2D) flow solutions in the semiconfining layer are compared for various hydraulic conductivity ratios between the aquifer and the semiconfining layer. Analysis of the drawdown data from an aquifer test in central Florida showed that the 3D solution in the semiconfining layer provides a more unique identification of the hydraulic parameters than the 2D solution. The analytical solution could be used to analyze, with higher accuracy, the effect that pumping water from the lower aquifer in a two-aquifer system has on wetlands.

  8. Aquifer test results, Green Swamp area, Florida

    USGS Publications Warehouse

    Tibbals, C.H.; Grubb, Hayes F.

    1982-01-01

    An aquifer test conducted in the Green Swamp area December 15-16 , 1975 was designed to stress the uppermost part of the Floridan aquifer so that the leakage characteristics of the overlying confining bed could be determined. A well tapping the upper part of the Floridan aquifer was pumped at a rate of about 1,040 gallons per minute for 35 hours; drawdown was measured in the Floridan aquifer and in two horizons in the confining bed. Analysis of the data indicates that the transmissivity of the uppper 160 feet of the Floridan is 13,000 square feet per day, the storage coefficient is about 0.0002.5, and the overlying confining bed leakance coefficient is about 0.02 to 0.025 per day. The vertical hydraulic diffusivity of the confining bed ranged from 610 square feet per day to 16,000 square feet per day. Results of the test indicate that, in the area of the test site, a Floridan aquifer well field would induce additional recharge to the Floridan. As a result of that increased recharge , water levels in the surficial aquifer would tend to stand lower, runoff from the area would tend to be less, and, perhaps, evapotranspiration would be less than normal.(USGS)

  9. Information fusion in regularized inversion of tomographic pumping tests

    USGS Publications Warehouse

    Bohling, Geoffrey C.; ,

    2008-01-01

    In this chapter we investigate a simple approach to incorporating geophysical information into the analysis of tomographic pumping tests for characterization of the hydraulic conductivity (K) field in an aquifer. A number of authors have suggested a tomographic approach to the analysis of hydraulic tests in aquifers - essentially simultaneous analysis of multiple tests or stresses on the flow system - in order to improve the resolution of the estimated parameter fields. However, even with a large amount of hydraulic data in hand, the inverse problem is still plagued by non-uniqueness and ill-conditioning and the parameter space for the inversion needs to be constrained in some sensible fashion in order to obtain plausible estimates of aquifer properties. For seismic and radar tomography problems, the parameter space is often constrained through the application of regularization terms that impose penalties on deviations of the estimated parameters from a prior or background model, with the tradeoff between data fit and model norm explored through systematic analysis of results for different levels of weighting on the regularization terms. In this study we apply systematic regularized inversion to analysis of tomographic pumping tests in an alluvial aquifer, taking advantage of the steady-shape flow regime exhibited in these tests to expedite the inversion process. In addition, we explore the possibility of incorporating geophysical information into the inversion through a regularization term relating the estimated K distribution to ground penetrating radar velocity and attenuation distributions through a smoothing spline model. ?? 2008 Springer-Verlag Berlin Heidelberg.

  10. Hydrogeologic data from the US Geological Survey test wells near Waycross, Ware County, Georgia

    USGS Publications Warehouse

    Matthews, S.E.; Krause, R.E.

    1983-01-01

    Two wells were constructed near Waycross, Ware County, Georgia, from July 1980 to May 1981 to collect stratigraphic, structural, geophysical, hydrologic, hydraulic, and geochemical information for the U.S. Geological Survey Tertiary Limestone Regional Aquifer-System Analysis. Data collection included geologic sampling and coring, borehole geophysical logging, packer testing, water-level measuring, water-quality sampling, and aquifer testing. In the study area, the Tertiary limestone aquifer system is about 1,300 feet thick and is confined and overlain by about 610 feet of clastic sediments. The aquifer system consists of limestone, dolomite, and minor evaporites and has high porosity and permeability. A 4-day continuous discharge aquifer test was conducted, from which a transmissivity of about 1 million feet squared per day and a storage coefficient of 0.0001 were calculated. Water from the upper part of the aquifer is of a calcium bicarbonate type. The deeper highly mineralized zone produces a sodium bicarbonate type water in which concentrations of magnesium, sulfate, chloride, sodium, and some trace metals increase with depth. (USGS)

  11. 18 CFR 806.12 - Constant-rate aquifer testing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... groundwater availability analysis to determine the availability of water during a 1-in-10-year recurrence... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Constant-rate aquifer testing. 806.12 Section 806.12 Conservation of Power and Water Resources SUSQUEHANNA RIVER BASIN...

  12. Predicting the denitrification capacity of sandy aquifers from in situ measurements using push-pull 15N tracer tests

    NASA Astrophysics Data System (ADS)

    Eschenbach, W.; Well, R.; Walther, W.

    2014-12-01

    Knowledge about the spatial variability of in situ denitrification rates (Dr(in situ)) and their relation to the denitrification capacity in nitrate-contaminated aquifers is crucial to predict the development of groundwater quality. Therefore, 28 push-pull 15N tracer tests for the measurement of in situ denitrification rates were conducted in two sandy Pleistocene aquifers in Northern Germany. The 15N analysis of denitrification derived 15N labelled N2 and N2O dissolved in water samples collected during the push-pull 15N tracer tests was performed by isotope ratio mass spectrometry (IRMS) in the lab and additionally for some tracer tests online in the field with a quadrupole membrane inlet mass spectrometer (MIMS), in order to test the feasibility of on-site real-time 15N analysis. Aquifer material from the same locations and depths as the push-pull injection points was incubated and the initial and cumulative denitrification after one year of incubation (Dcum(365)) as well as the stock of reduced compounds (SRC) was compared with in situ measurements of denitrification. This was done to derive transfer functions suitable to predict Dcum(365) and SRC from Dr(in situ). Dr(in situ) ranged from 0 to 51.5 μg N kg-1 d-1. Denitrification rates derived from on-site isotope analysis using membrane-inlet mass spectrometry satisfactorily coincided with laboratory analysis by conventional isotope ratio mass spectrometry, thus proving the feasibility of in situ analysis. Dr(in situ) was significantly higher in the sulphidic zone of both aquifers compared to the zone of non-sulphidic aquifer material. Overall, regressions between the Dcum(365) and SRC of the tested aquifer material with Dr(in situ) exhibited only a modest linear correlation for the full data set. But the predictability of Dcum(365) and SRC from Dr(in situ) data clearly increased for aquifer samples from the zone of NO3--bearing groundwater. In the NO3--free aquifer zone a lag phase of denitrification after NO3- injections was observed, which confounded the relationship between reactive compounds and in situ denitrification activity. This finding was attributed to adaptation processes in the microbial community after NO3- injections. Exemplarily, it was demonstrated that the microbial community in the NO3--free zone close below the NO3--bearing zone can be adapted to denitrification by amending wells with NO3--injections for an extended period. In situ denitrification rates were 30 to 65% higher after pre-conditioning with NO3-. Results from this study suggest that such pre-conditioning is crucial for the measurement of Dr(in situ) in deeper aquifer material from the NO3--free groundwater zone and thus for the prediction of Dcum(365) and SRC from Dr(in situ).

  13. Predicting the denitrification capacity of sandy aquifers from in situ measurements using push-pull 15N tracer tests

    NASA Astrophysics Data System (ADS)

    Eschenbach, W.; Well, R.; Walther, W.

    2015-04-01

    Knowledge about the spatial variability of in situ denitrification rates (Dr(in situ)) and their relation to the denitrification capacity in nitrate-contaminated aquifers is crucial to predict the development of groundwater quality. Therefore, 28 push-pull 15N tracer tests for the measurement of in situ denitrification rates were conducted in two sandy Pleistocene aquifers in northern Germany. The 15N analysis of denitrification-derived 15N-labelled N2 and N2O dissolved in water samples collected during the push-pull 15N tracer tests was performed using isotope ratio mass spectrometry (IRMS) in the lab and additionally for some tracer tests online in the field with a quadrupole membrane inlet mass spectrometer (MIMS) in order to test the feasibility of on-site real-time 15N analysis. Aquifer material from the same locations and depths as the push-pull injection points was incubated, and the initial and cumulative denitrification after 1 year of incubation (Dcum(365)) as well as the stock of reduced compounds (SRC) was compared with in situ measurements of denitrification. This was done to derive transfer functions suitable to predict Dcum(365) and SRC from Dr(in situ). Dr(in situ) ranged from 0 to 51.5 μg N kg-1 d-1. Denitrification rates derived from on-site isotope analysis using MIMS satisfactorily coincided with laboratory analysis by conventional IRMS, thus proving the feasibility of in situ analysis. Dr(in situ) was significantly higher in the sulfidic zone of both aquifers compared to the zone of non-sulfidic aquifer material. Overall, regressions between the Dcum(365) and SRC of the tested aquifer material with Dr(in situ) exhibited only a modest linear correlation for the full data set. However, the predictability of Dcum(365) and SRC from Dr(in situ) data clearly increased for aquifer samples from the zone of NO3--bearing groundwater. In the NO3--free aquifer zone, a lag phase of denitrification after NO3- injections was observed, which confounded the relationship between reactive compounds and in situ denitrification activity. This finding was attributed to adaptation processes in the microbial community after NO3- injections. It was also demonstrated that the microbial community in the NO3--free zone just below the NO3--bearing zone can be adapted to denitrification by NO3- injections into wells for an extended period. In situ denitrification rates were 30 to 65 times higher after pre-conditioning with NO3-. Results from this study suggest that such pre-conditioning is crucial for the measurement of Dr(in situ) in deeper aquifer material from the NO3--free groundwater zone and thus for the prediction of Dcum(365) and SRC from Dr(in situ).

  14. Hydrogeologic characterization of a fractured granitic rock aquifer, Raymond, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohen, Andrew J.B.

    1993-10-01

    The hydrogeologic properties of a shallow, fractured granitic rock aquifer in the foothills of the Sierra Nevada, California were investigated via the analysis of borehole geophysical logs and pumping tests. The drawdowns produced during these tests are not indicative of any simple conceptual aquifer model, and borehole logs show that the granite is intensely fractured. These observations are suggestive of a complex fracture-flow geometry which is extremely difficult to decipher. However, through the measurement of orientations of individual subsurface fractures from acoustic televiewer logs, and correlation between particular fractures and electrical resistivity and thermal-pulse flowmeter logs, it was found thatmore » the aquifer is, in general, comprised of two subhorizontal and nearly parallel zones of unloading fractures. Downhole flowmeter measurements taken in several wells provide further evidence for the inferred dual-layer structure of the aquifer, as well as yield quantitative measures of the contribution of flow from each zone. Analysis of drawdowns in pumped wells reveals that there are zones of relatively high transmissivity immediately around them. It was found that these properties, as well as a nearby zone of lower transmissivity, can account for their observed drawdowns. A numerical model was constructed to test whether these major heterogeneities could also account for the drawdowns in observation wells. This stepwise analysis of both the geophysical and hydrological data resulted in the formulation of a conceptual model of the aquifer which is consistent with observations, and which can account for its behavior when subjected to pumping.« less

  15. Cyclic injection, storage, and withdrawal of heated water in a sandstone aquifer at St. Paul, Minnesota: Field observations, preliminary model analysis, and aquifer thermal efficiency

    USGS Publications Warehouse

    Miller, Robert T.

    1989-01-01

    The Franconia-Ironton-Galesville aquifer is a consolidated sandstone, approximately 60 m thick, the top of which is approximately 180 m below the land surface. It is confined above by the St. Lawrence Formation--a dolomitic sandstone 8-m thick--and below by the Eau Claire Formation--a shale 30-m thick. Initial hydraulic testing with inflatable packers indicated that the aquifer has four hydraulic zones with distinctly different values of relative horizontal hydraulic conductivity. The thickness of each zone was determined by correlating data from geophysical logs, core samples, and the inflatablepacker tests.

  16. The effect of the Baton Rouge fault on flow in the Abita aquifer of southeastern Louisiana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rapp, T.R.

    1993-03-01

    The ground-water resources of southern Tangipahoa Parish and adjacent areas were studied to determine their potential for development as an alternative to the Mississippi River as a water supply source for Jefferson Parish, Louisiana. The study area, in southeastern Louisiana, is underlain by eight major aquifers and is crossed by a fault zone, referred to as the Baton Rouge fault. The fault restricts the flow of water in the aquifers of intermediate depth. Data from a test well drilling program and geophysical logs of a nearby oil well indicated that a significant freshwater aquifer that provides water to a nearbymore » municipality was actually the Abita aquifer and not the Covington aquifer, as was previously thought. The Abita aquifer, a shallower aquifer with a lower hydraulic conductivity, had been displaced to a position equivalent to that of the Covington aquifer by the Baton Rouge fault. An additional final test well drilled south of the fault penetrated the leading edge of a wedge-shaped saltwater interface. Analysis of lithologic and geophysical logs indicated that the Abita aquifer has a well-sorted, clean sand at the base of the aquifer and substantial amounts of clay in the top two-thirds of the aquifer. Geophysical logs of oil test wells south of the fault zone indicated that the sand thickens substantially to the south. The thicker sand south of a public supply well that pumps water from the Abita aquifer and the higher hydraulic conductivity of the lower part of the aquifer where the saline water was detected indicate that a much larger percentage of recharge to the public supply well may come from the south than was originally thought.« less

  17. Analysis of Tide and Offshore Storm-Induced Water Table Fluctuations for Structural Characterization of a Coastal Island Aquifer

    NASA Astrophysics Data System (ADS)

    Trglavcnik, Victoria; Morrow, Dean; Weber, Kela P.; Li, Ling; Robinson, Clare E.

    2018-04-01

    Analysis of water table fluctuations can provide important insight into the hydraulic properties and structure of a coastal aquifer system including the connectivity between the aquifer and ocean. This study presents an improved approach for characterizing a permeable heterogeneous coastal aquifer system through analysis of the propagation of the tidal signal, as well as offshore storm pulse signals through a coastal aquifer. Offshore storms produce high wave activity, but are not necessarily linked to significant onshore precipitation. In this study, we focused on offshore storm events during which no onshore precipitation occurred. Extensive groundwater level data collected on a sand barrier island (Sable Island, NS, Canada) show nonuniform discontinuous propagation of the tide and offshore storm pulse signals through the aquifer with isolated inland areas showing enhanced response to both oceanic forcing signals. Propagation analysis suggests that isolated inland water table fluctuations may be caused by localized leakage from a confined aquifer that is connected to the ocean offshore but within the wave setup zone. Two-dimensional groundwater flow simulations were conducted to test the leaky confined-unconfined aquifer conceptualization and to identify the effect of key parameters on tidal signal propagation in leaky confined-unconfined coastal aquifers. This study illustrates that analysis of offshore storm signal propagation, in addition to tidal signal propagation, provides a valuable and low resource approach for large-scale characterization of permeable heterogeneous coastal aquifers. Such an approach is needed for the effective management of coastal environments where water resources are threatened by human activities and the changing climate.

  18. Program to analyze aquifer test data and check for validity with the jacob method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Field, M.S.

    1993-01-01

    The Jacob straight-line method of aquifer analysis deals with the late-time data and small radius of the Theis type curve which plot as a straight line if the drawdown data are plotted on an arithmetic scale and the time data on a logarithmic (base 10) scale. Correct analysis with the Jacob method normally assumes that (1) the data lie on a straight line, (2) the value of the dimensionless time factor is less than 0.01, and (3) the site's hydrogeology conforms to the method's assumptions and limiting conditions. Items 1 and 2 are usually considered for the Jacob method, butmore » item 3 is often ignored, which can lead to incorrect calculations of aquifer parameters. A BASIC computer program was developed to analyze aquifer test data with the Jacob method to test the validity of its use. Aquifer test data are entered into the program and manipulated so that a slope and time intercept of the straight line drawn through the data (excluding early-time and late-time data) can be used to calculate transmissivity and storage coefficient. Late-time data are excluded to eliminate the effects of positive and negative boundaries. The time-drawdown data then are converted into dimensionless units to determine if the Jacob method's assumptions are valid for the hydrogeologic conditions under which the test was conducted.« less

  19. Analysis of three tests of the unconfined aquifer in southern Nassau County, Long Island, New York

    USGS Publications Warehouse

    Lindner, J.B.; Reilly, T.E.

    1982-01-01

    Drawdown and recovery data from three 2-day aquifer tests (OF) the unconfined (water-table) aquifer in southern Nassau County, N.Y., during the fall of 1979, were analyzed. Several simple analytical solutions, a typecurve-matching procedure, and a Galerkin finite-element radial-flow model were used to determine hydraulic conductivity, ratio of horizontal to vertical hydraulic conductivity, and specific yield. Results of the curve-matching procedure covered a broad range of values that could be narrowed through consideration of data from other sources such as published reports, drillers ' logs, or values determined by analytical solutions. Analysis by the radial-flow model was preferred because it allows for vertical variability in aquifer properties and solves the system for all observation points simultaneously, whereas the other techniques treat the aquifer as homogeneous and must treat each observation well separately. All methods produced fairly consistent results. The ranges of aquifer values at the three sites were: horizontal hydraulic conductivity, 140 to 380 feet per day; transmissivity 11,200 to 17,100 feet squared per day; ratio of horizontal to vertical hydraulic conductivity 2.4:1 to 7:1, and specific yield , 0.13 to 0.23. (USGS)

  20. Determination of hydraulic properties in the vicinity of a landfill near Antioch, Illinois

    USGS Publications Warehouse

    Kay, Robert T.; Earle, John D.

    1990-01-01

    A hydrogeologic investigation was conducted in and around a landfill near Antioch, Illinois, in December 1987. The investigation consisted, in part, of an aquifer test that was designed to determine the hydraulic connection between the hydrogeologic units in the area. The hydrogeologic units consist of a shallow, unconfined, sand and gravel aquifer of variable thickness that overlies an intermediate confining unit of variable thickness composed predominantly of till. Underlying the till is a deep, confined, sand and gravel aquifer that serves as the water supply for the village of Antioch. The aquifer test was conducted in the confined aquifer. Aquifer-test data were analyzed using the Hantush and Jacob method for a leaky confined aquifer with no storage in the confining unit. Calculated transmissivity of the confined aquifer ranged from 1.96x10^4 to 2.52x10^4 foot squared per day and storativity ranged from 2.10x10^-4 to 8.71x10^-4. Leakage through the confining unit ranged from 1.29x10^-4 to 7.84x10^-4 foot per day per foot, and hydraulic conductivity of the confining unit ranged from 3.22x10^-3 to 1.96x10^-2 foot per day. The Hantush method for analysis of a leaky confined aquifer with storage in the confining unit also was used to estimate aquifer and confining-unit properties. Transmissivity and storativity values calculated using the Hantush method are in good agreement with the values calculated from the Hantush and Jacob method. Properties of the confining unit were estimated using the ratio method of Neuman and Witherspoon. The estimated diffusivity of the confining unit ranged from 50.36 to 68.13 feet squared per day, A value for the vertical hydraulic conductivity of the confining unit calculated from data obtained using both the Hantush and the Neuman and Witherspoon methods was within the range of values calculated by the Hantush and Jacob method. The aquifer-test data clearly showed that the confining unit is hydraulically connected to the confined aquifer. The aquifer-test data also indicated that the unconfined aquifer becomes hydraulically connected to the deep sand and gravel aquifer within 24 hours after the start of pumping in the confined aquifer.

  1. Selected data on characteristics of glacial-deposit and carbonate-rock aquifers, midwestern basins and arches region

    USGS Publications Warehouse

    Joseph, R.L.; Eberts, S.M.

    1994-01-01

    In 1988, the Geological Survey (USGS) began study to examine the hydrogeologic framework, ground-water-flow systems, water chemistry, and withdrawal response of aquifers in glacial deposits and carbonate rock in the Midwestern Basins and Arches Region in western Ohio and eastern Indiana. As part of this study, data from pumped-well tests and instantaneous-rechange tests (slug tests) of wells completed in the glacial-deposit and carbonate-rock aquifers were compiled from reports and information on file with State agencies, environmental consulting firms, drilling firms, municipalities, universities, and the USGS. The data, from 73 counties in Ohio and Indiana, were entered into a computerized data base in a spreadsheet format and subsequently into a geographic information system (GIS). Aquifer-characteristics data from this compilation include the results of 105 pumped-well tests and 39 slug tests in wells completed in glacial deposits, 174 pumped-well tests in wells completed in the carbonate-rock aquifer, and 4 slug tests in wells completed in limestones and shales of Ordovician age. Transmissivities from the pumped-well tests in wells completed in glacial till and glacial-deposit aquifers (sands and gravels) range from 1.54 to 69,700 feet squared per day. Storage coefficients or specific yields range from 0.00002 to 0.38 at these wells. Horizontal-hydraulic conductivities from the slug tests in wells completed in glacial-deposit aquifers range from 0.33 to 1,000 feet per day. Transmissivities from the pumped-well tests in wells completed in the carbonate-rock aquifer range from 70 to 52,000 feet squared per day. Storage coefficient or specific yields at these wells range from 0.00001 to 0.05. Horizontal hydraulic conductivities from the slug tests in wells completed in limestones and shales of Ordovician age range from 0.0016 to 12 feet per day. These data are summarized in tables and figures within this report. The collection and compilation of selected aquifer-characteristic data for the glacial-deposit and carbonate-rock aquifers within the Midwestern Basin and Arches Region of Shaver (1985) are an essential part of the Midwestern Basins and Arches Regional Aquifer-Systems Analysis (Midwestern Basins and Arches RASA) project of the U.S. Geological Survey (USGS). Specifically, the data are needed to help describe ground-water flow in the regional aquifer system, which isone of the objectives of the Midwestern Basins and Arches RASA project (Bugliosi, 1990). To meet this objective, the Midwestern Basins and Arches RASA began subprojects in the Ohio and Indiana offices of the USGS to collect and compile available aquifer-characteristics data from aquifer tests of the glacial-deposit and carbonate-rock aquifers. The data were not reanalyzed to verify accuracy because of time constraints and insufficient data in many cases.

  2. Summary of well construction, testing, and preliminary findings from the Alligator Alley test well, Broward County, Florida

    USGS Publications Warehouse

    Meyer, F.W.

    1988-01-01

    A 2,811-foot deep test well was drilled during 1980 in The Everglades along Alligator Alley as part of the Floridan Regional Aquifer Systems Analysis project. The well was cased 895 feet deep. Hydraulic packers were used to isolate selected zones in the open hole for water samples and measurement of water levels. The well penetrated the surficial and intermediate aquifers into the Floridan aquifer system. The top of the Floridan aquifer system occurs at 770 feet and includes limestone ranging in age from Oligocene to early Eocene. About 67 percent of the total thickness of the Floridan aquifer system was penetrated by the well. The chief water-producing zones in the Floridan aquifer system occur at about 1,030 feet and at about 2,560 feet. The 1,030-foot zone contains brackish artesian groundwater, and the 2,560-foot zone contains salty artesian groundwater similar in composition to seawater. The static water geothermal gradient is indicated, and radiocarbon activities suggest that the saltwater in the lower zone is younger than brackish groundwater in the upper zone. (USGS)

  3. Analysis of complex pumping interactions during an aquifer test conducted at a well field in the coastal plain near Augusta, Georgia, October 2009

    USGS Publications Warehouse

    Gonthier, Gerald J.

    2009-01-01

    A 24-hour aquifer test was conducted in Well Field 2 near Augusta, Georgia, October 21–22, 2009, to characterize the hydraulic properties of the Midville aquifer system. The selected well was pumped at a rate of 684 gallons per minute. At the initiation of aquifer-test pumping, water levels in each of eight wells monitored for the test were still recovering from the well-field production. Because water levels had not stabilized, data analyses were needed to account for the ongoing recovery. Hydraulic properties of the Midville aquifer system were estimated by an approach based on the Theis model and superposition. The Midville aquifer system was modeled as a Theis aquifer. The principle of superposition was used to sum the effects of multiple pumping and recovery events from a single pumped well and to sum the effects of all pumped wells as the estimated total drawdown at a monitored well. Simulated drawdown at each monitored well was determined by using a spreadsheet (SUMTheis) function of aquifer transmissivity and storativity. Simulated drawdown values were transformed into simulated water levels, accounting for longterm water-level trends. The transmissivity and storativity values that were used to calibrate the simulated water levels to measured water levels (roughly 4,000 square feet per day and 2E-04, respectively) provide estimates of the transmissivity and storativity of the Midville aquifer system in the vicinity of Well Field 2. The approach used in this study can be applied to similar well-field tests in which incomplete drawdown recovery or other known pumping is evident.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prince, K.R.; Schneider, B.J.

    This study obtained estimates of the hydraulic properties of the upper glacial and Magothy aquifers in the East Meadow area for use in analyzing the movement of reclaimed waste water through the aquifer system. This report presents drawdown and recovery data form the two aquifer tests of 1978 and 1985, describes the six methods of analysis used, and summarizes the results of the analyses in tables and graphs. The drawdown and recovery data were analyzed through three simple analytical equations, two curve-matching techniques, and a finite-element radial-flow model. The resulting estimates of hydraulic conductivity, anisotropy, and storage characteristics were usedmore » as initial input values to the finite-element radial-flow model (Reilly, 1984). The flow model was then used to refine the estimates of the aquifer properties by more accurately representing the aquifer geometry and field conditions of the pumping tests.« less

  5. Summary of hydrologic testing of the Floridan aquifer system at Fort Stewart, coastal Georgia, 2009-2010

    USGS Publications Warehouse

    Gonthier, Gerald J.

    2011-01-01

    Two test wells were completed at Fort Stewart, coastal Georgia, to investigate the potential for using the Lower Floridan aquifer as a source of water to satisfy anticipated, increased water needs. The U.S. Geological Survey, in cooperation with the U.S. Department of the Army, completed hydrologic testing of the Floridan aquifer system at the study site, including flowmeter surveys, slug tests, and 24- and 72-hour aquifer tests by mid-March 2010. Analytical approaches and model simulation were applied to aquifer-test results to provide estimates of transmissivity and hydraulic conductivity of the multilayered Floridan aquifer system. Data from a 24-hour aquifer test of the Upper Floridan aquifer were evaluated by using the straight-line Cooper-Jacob analytical method. Data from a 72-hour aquifer test of the Lower Floridan aquifer were simulated by using axisymmetric model simulations. Results of aquifer testing indicated that the Upper Floridan aquifer has a transmissivity of 100,000 feet-squared per day, and the Lower Floridan aquifer has a transmissivity of 7,000 feet-squared per day. A specific storage for the Floridan aquifer system as a result of model calibration was 3E-06 ft–1. Additionally, during a 72-hour aquifer test of the Lower Floridan aquifer, a drawdown response was observed in two Upper Floridan aquifer wells, one of which was more than 1 mile away from the pumped well.

  6. Well installation, single-well testing, and particle-size analysis for selected sites in and near the Lost Creek Designated Ground Water Basin, north-central Colorado, 2003-2004

    USGS Publications Warehouse

    Beck, Jennifer A.; Paschke, Suzanne S.; Arnold, L. Rick

    2011-01-01

    This report describes results from a groundwater data-collection program completed in 2003-2004 by the U.S. Geological Survey in support of the South Platte Decision Support System and in cooperation with the Colorado Water Conservation Board. Two monitoring wells were installed adjacent to existing water-table monitoring wells. These wells were installed as well pairs with existing wells to characterize the hydraulic properties of the alluvial aquifer and shallow Denver Formation sandstone aquifer in and near the Lost Creek Designated Ground Water Basin. Single-well tests were performed in the 2 newly installed wells and 12 selected existing monitoring wells. Sediment particle size was analyzed for samples collected from the screened interval depths of each of the 14 wells. Hydraulic-conductivity and transmissivity values were calculated after the completion of single-well tests on each of the selected wells. Recovering water-level data from the single-well tests were analyzed using the Bouwer and Rice method because test data most closely resembled those obtained from traditional slug tests. Results from the single-well test analyses for the alluvial aquifer indicate a median hydraulic-conductivity value of 3.8 x 10-5 feet per second and geometric mean hydraulic-conductivity value of 3.4 x 10-5 feet per second. Median and geometric mean transmissivity values in the alluvial aquifer were 8.6 x 10-4 feet squared per second and 4.9 x 10-4 feet squared per second, respectively. Single-well test results for the shallow Denver Formation sandstone aquifer indicate a median hydraulic-conductivity value of 5.4 x 10-6 feet per second and geometric mean value of 4.9 x 10-6 feet per second. Median and geometric mean transmissivity values for the shallow Denver Formation sandstone aquifer were 4.0 x 10-5 feet squared per second and 5.9 x 10-5 feet squared per second, respectively. Hydraulic-conductivity values for the alluvial aquifer in and near the Lost Creek Designated Ground Water Basin generally were greater than hydraulic-conductivity values for the Denver Formation sandstone aquifer and less than hydraulic-conductivity values for the alluvial aquifer along the main stem of the South Platte River Basin reported by previous studies. Particle sizes were analyzed for a total of 14 samples of material representative of the screened interval in each of the 14 wells tested in this study. Of the 14 samples collected, 8 samples represent the alluvial aquifer and 6 samples represent the Denver Formation sandstone aquifer in and near the Lost Creek Designated Ground Water Basin. The sampled alluvial aquifer material generally contained a greater percentage of large particles (larger than 0.5 mm) than the sampled sandstone aquifer material. Alternatively, the sampled sandstone aquifer material generally contained a greater percentage of fine particles (smaller than 0.5 mm) than the sampled alluvial aquifer material consistent with the finding that the alluvial aquifer is more conductive than the sandstone aquifer in the vicinity of the Lost Creek Designated Ground Water Basin.

  7. Hydrogeology and water quality of the Dublin and Midville aquifer systems at Waynesboro, Burke County, Georgia, 2011

    USGS Publications Warehouse

    Gonthier, Gerard

    2013-01-01

    The hydrogeology and water quality of the Dublin and Midville aquifer systems were characterized in the City of Waynesboro area in Burke County, Georgia, based on geophysical and drillers’ logs, flowmeter surveys, a 24-houraquifer test, and the collection and chemical analysis of water samples in a newly constructed well. At the test site, the Dublin aquifer system consists of interlayered sands and clays between depths of 396 and 691 feet, and the Midville aquifer system consists of a sandy clay layer overlying a sand and gravel layer between depths of 728 and 936 feet. The new well was constructed with three screened intervals in the Dublin aquifer system and four screened intervals in the Midville aquifer system. Wellbore-flowmeter testing at a pumping rate of 1,000 gallons per minute indicated that 52.2 percent of the total flow was from the shallower Dublin aquifer system with the remaining 47.8 percent from the deeper Midville aquifer system. The lower part of the lower Midville aquifer (900 to 930 feet deep), contributed only 0.1 percent of the total flow. Hydraulic properties of the two aquifer systems were estimated using data from two wellbore-flowmeter surveys and a 24-hour aquifer test. Estimated values of transmissivity for the Dublin and Midville aquifer systems were 2,000 and 1,000 feet squared per day, respectively. The upper and lower Dublin aquifers have a combined thickness of about 150 feet and the horizontal hydraulic conductivity of the Dublin aquifer system averages 10 feet per day. The upper Midville aquifer, lower Midville confining unit, and lower Midville aquifer have a combined thickness of about 210 feet, and the horizontal hydraulic conductivity of the Midville aquifer system averages 6 feet per day. Storage coefficient of the Dublin aquifer system, computed using the Theis method on water-level data from one observation well, was estimated to be 0.0003. With a thickness of about 150 feet, the specific storage of the Dublin aquifer system averages about 2×10-6 per foot. Water quality of the Dublin and Midville aquifer systems was characterized during the aquifer test on the basis of water samples collected from composite well flow originating from five depths in the completed production well during the aquifer test. Samples were analyzed for total dissolved solids, specific conductance, pH, alkalinity, and major ions. Water-quality results from composite samples, known flow contribution from individual screens, and a mixing equation were used to calculate water-quality values for sample intervals between sample depths or below the bottom sample depth. With the exception of iron and manganese, constituent concentrations of water from each of the sampled intervals and total flow from the well were within U.S. Environmental Protection Agency primary and secondary drinking-water standards. Water from the bottommost sample interval in the lower part of the lower Midville aquifer (900 to 930 feet) contained manganese and iron concentrations of 59.1 and 1,160 micrograms per liter, respectively, which exceeded secondary drinking-water standards. Because this interval contributed only 0.1 percent of the total flow to the well, water quality of this interval had little effect on the composite well water quality. Two other sample intervals from the Midville aquifer system and the total flow from both aquifer systems contained iron concentrations that slightly exceeded the secondary drinking-water standard of 300 micrograms per liter.

  8. Hydrostratigraphy and hydrogeology of the western part of Maira area, Khyber Pakhtunkhwa, Pakistan: a case study by using electrical resistivity.

    PubMed

    Farid, Asam; Jadoon, Khanzaib; Akhter, Gulraiz; Iqbal, Muhammad Asim

    2013-03-01

    Hydrostratigraphy and hydrogeology of the Maira vicinity is important for the characterization of aquifer system and developing numerical groundwater flow models to predict the future availability of the water resource. Conventionally, the aquifer parameters are obtained by the analysis of pumping tests data which provide limited spatial information and turn out to be costly and time consuming. Vertical electrical soundings and pump testing of boreholes were conducted to delineate the aquifer system at the western part of the Maira area, Khyber Pakhtun Khwa, Pakistan. Aquifer lithology in the eastern part of the study area is dominated by coarse sand and gravel whereas the western part is characterized by fine sand. An attempt has been made to estimate the hydraulic conductivity of the aquifer system by establishing a relationship between the pumping test results and vertical electrical soundings by using regression technique. The relationship is applied to the area along the resistivity profiles where boreholes are not drilled. Our findings show a good match between pumped hydraulic conductivity and estimated hydraulic conductivity. In case of sparse borehole data, regression technique is useful in estimating hydraulic properties for aquifers with varying lithology.

  9. Data for ground-water test hole near Nicolaus, Central Valley aquifer project, California

    USGS Publications Warehouse

    French, James J.; Page, R.W.; Bertoldi, Gilbert L.

    1983-01-01

    Preliminary data are provided for the third of seven test holes drilled as a part of the Central Valley Aquifer Project which is part of the National Regional Aquifer Systems Analysis Program. The test hole was drilled in the SW 1/4 NE 1/4 sec. 2, T.12N., R.3E., Sutter County, California, about 1 1/2 miles northwest of the town of Nicolaus. Drilled to a depth of 1,150 feet below land surface, the hole is cased to a depth of 100 feet and equipped with three piezometer tubes to depths of 311, 711, and 1,071 feet. A 5-foot well screen is set in sand at the bottom of each piezometer. Each screened interval has a cement plug above and below it to isolate it from other parts of the aquifer, and the well bore is filled between the plugs with sediment. Thirty-one cores and 34 sidewall cores were recovered. Laboratory tests were made for minerology, consolidation, grain-size distribution, Atterberg limits, X-ray diffraction, thermal conductivity, and chemical analysis of water. Geophysical and thermal gradient logs were made. The hole is sampled periodically for chemical analysis of the three tapped zones and measured for water level. This report presents methods used to obtain field samples, laboratory procedures, and the data obtained. (USGS)

  10. Conceptualization of flow and transport in a limestone aquifer by multiple dedicated hydraulic and tracer tests

    NASA Astrophysics Data System (ADS)

    Mosthaf, Klaus; Brauns, Bentje; Fjordbøge, Annika S.; Rohde, Magnus M.; Kerrn-Jespersen, Henriette; Bjerg, Poul L.; Binning, Philip J.; Broholm, Mette M.

    2018-06-01

    Limestone aquifers are of great interest as a drinking water resource in many countries. They often have a complex crushed and fractured geology, which makes the analysis and description of flow and transport processes in such aquifers a challenging task. In this study, the solute transport behavior including fracture-matrix interaction in hydrogeological units of a limestone aquifer in eastern Denmark was characterized by designing, conducting and interpreting six depth-specific tracer tests involving natural- and forced-gradient conditions with multiple tracers representing different diffusion properties. To determine flow parameters, the tracer tests were complemented by a comprehensive set of depth-specific borehole and hydraulic tests. Based on the tests, a new and stronger conceptual understanding was developed for the different aquifer units. The investigated limestone aquifer is composed of a glacially crushed unit and two fractured units, with calcarenitic and bryozoan limestone of similar hydraulic properties. Hydraulic tests revealed that the crushed unit has a lower hydraulic conductivity than the fractured limestone units, likely due to the crushed conditions with small limestone clusters and small-aperture fractures potentially filled with fine material. In the fractured limestone units, a distinct preferential flow and primary transport along major horizontal fractures was inferred from the tracer tests under forced-gradient conditions. The dominant horizontal fractures were identified on impeller flow logs and appear connected between wells, having an extent of up to several hundred meters. Connectivity between the aquifer units was investigated with a long-term pumping test and tracer tests, revealing restricted vertical flow and transport. A very pronounced hydraulic conductivity contrast between major fractures and matrix could also be inferred from the borehole and hydraulic tests, which is consistent with the findings from the tracer tests. The difference in the matrix diffusion behavior of the simultaneously injected tracers and a long tailing in the breakthrough curves revealed that matrix diffusion has a strong influence on the solute transport in the fractured limestone.

  11. Analysis of Slug Tests in Formations of High Hydraulic Conductivity

    USGS Publications Warehouse

    Butler, J.J.; Garnett, E.J.; Healey, J.M.

    2003-01-01

    A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.

  12. Analysis of slug tests in formations of high hydraulic conductivity.

    PubMed

    Butler, James J; Garnett, Elizabeth J; Healey, John M

    2003-01-01

    A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.

  13. Hydrologeology and water quality of the Floridan aquifer system and effect of Lower Floridan aquifer pumping on the Upper Floridan aquifer, Pooler, Chatham County, Georgia, 2011–2012

    USGS Publications Warehouse

    Gonthier, Gerard

    2012-01-01

    Two test wells were completed in Pooler, Georgia, in 2011 to investigate the potential of using the Lower Floridan aquifer as a source of water for municipal use. One well was completed in the Lower Floridan aquifer at a depth of 1,120 feet (ft) below land surface; the other well was completed in the Upper Floridan aquifer at a depth of 486 ft below land surface. At the Pooler test site, the U.S. Geological Survey performed flowmeter surveys, packer-isolated slug tests within the Lower Floridan confining unit, slug tests of the entire Floridan aquifer system, and aquifer tests of the Upper and Lower Floridan aquifers. Drill cuttings, geophysical logs, and borehole flowmeter surveys indicate that the Upper Floridan aquifer extends 333 –515 ft below land surface, the Lower Floridan confining unit extends 515–702 ft below land surface, and the Lower Floridan aquifer extends 702–1,040 ft below land surface. Flowmeter surveys indicate that the Upper Floridan aquifer contains two water-bearing zones at depth intervals of 339 –350 and 375–515 ft; the Lower Floridan confining unit contains one zone at a depth interval of 550–620 ft; and the Lower Floridan aquifer contains five zones at depth intervals of 702–745, 745–925, 925–984, 984–1,015, and 1,015–1,040 ft. Flowmeter testing of the test borehole open to the entire Floridan aquifer system indicated that the Upper Floridan aquifer contributed 92.4 percent of the total flow rate of 708 gallons per minute; the Lower Floridan confining unit contributed 3.0 percent; and the Lower Floridan aquifer contributed 4.6 percent. Horizontal hydraulic conductivity of the Lower Floridan confining unit derived from slug tests within three packer-isolated intervals ranged from 0.5 to 10 feet per day (ft/d). Aquifer-test analyses yielded values of transmissivity for the Upper Floridan aquifer, Lower Floridan confining unit, and the Lower Floridan aquifer of 46,000, 700, and 4,000 feet squared per day (ft2/d), respectively. Horizontal hydraulic conductivity of 4 ft/d for the Lower Floridan confining unit, derived from aquifer-test analyses, is near the midrange for values derived from packer-isolated slug tests. The transmissivity of the entire Floridan aquifer system derived from aquifer-test analyses totals about 51,000 ft2/d, similar to the value of 58,000 ft2/d derived from open slug tests on the entire Floridan aquifer system. Water-level data for each aquifer test were filtered for external influences such as barometric pressure, earth-tide effects, and long-term trends to enable detection of small (less than 1 foot) water-level responses to aquifer-test pumping. During the 72-hour aquifer test of pumping the Lower Floridan aquifer, a drawdown response of 51.7 ft was observed in the Lower Floridan pumped well and a drawdown response of 0.9 foot was observed in the Upper Floridan observation well located 85 ft from the pumped well.

  14. Field demonstration of CO2 leakage detection and potential impacts on groundwater quality at Brackenridge Field Laboratory

    NASA Astrophysics Data System (ADS)

    Zou, Y.; Yang, C.; Guzman, N.; Delgado, J.; Mickler, P. J.; Horvoka, S.; Trevino, R.

    2015-12-01

    One concern related to GCS is possible risk of unintended CO2 leakage from the storage formations into overlying potable aquifers on underground sources of drinking water (USDW). Here we present a series of field tests conducted in an alluvial aquifer which is on a river terrace at The University of Texas Brackenridge Field Laboratory. Several shallow groundwater wells were completed to the limestone bedrock at a depth of 6 m and screened in the lower 3 m. Core sediments recovered from the shallow aquifer show that the sediments vary in grain size from clay-rich layers to coarse sandy gravels. Two main types of field tests were conducted at the BFL: single- (or double-) well push-pull test and pulse-like CO2 release test. A single- (or double-) well push-pull test includes three phases: the injection phase, the resting phase and pulling phase. During the injection phase, groundwater pumped from the shallow aquifer was stored in a tank, equilibrated with CO2 gasand then injected into the shallow aquifer to mimic CO2 leakage. During the resting phase, the groundwater charged with CO2 reacted with minerals in the aquifer sediments. During the pulling phase, groundwater was pumped from the injection well and groundwater samples were collected continuously for groundwater chemistry analysis. In such tests, large volume of groundwater which was charged with CO2 can be injected into the shallow aquifer and thus maximize contact of groundwater charged with CO2. Different than a single- (or double-) well push-pull test, a pulse-like CO2 release test for validating chemical sensors for CO2 leakage detection involves a CO2 release phase that CO2 gas was directly bubbled into the testing well and a post monitoring phase that groundwater chemistry was continuously monitored through sensors and/or grounder sampling. Results of the single- (or double-) well push-pull tests conducted in the shallow aquifer shows that the unintended CO2 leakage could lead to dissolution of carbonates and some silicates and mobilization of heavy metals from the aquifer sediments to groundwater, however, such mobilization posed no risks on groundwater quality at this site. The pulse-like tests have demonstrated it is plausible to use chemical sensors for CO2 leakage detection in groundwater.

  15. Site characterization methodology for aquifers in support of bioreclamation activities. Volume 2: Borehole flowmeter technique, tracer tests, geostatistics and geology. Final report, August 1987-September 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, S.C.

    1993-08-01

    This report discusses a field demonstration of a methodology for characterizing an aquifer's geohydrology in the detail required to design an optimum network of wells and/or infiltration galleries for bioreclamation systems. The project work was conducted on a 1-hectare test site at Columbus AFB, Mississippi. The technical report is divided into two volumes. Volume I describes the test site and the well network, the assumptions, and the application of equations that define groundwater flow to a well, the results of three large-scale aquifer tests, and the results of 160 single-pump tests. Volume II describes the bore hole flowmeter tests, themore » tracer tests, the geological investigations, the geostatistical analysis and the guidelines for using groundwater models to design bioreclamation systems. Site characterization, Hydraulic conductivity, Groundwater flow, Geostatistics, Geohydrology, Monitoring wells.« less

  16. Hydrogeologic characteristics and water quality of a confined sand unit in the surficial aquifer system, Hunter Army Airfield, Chatham County, Georgia

    USGS Publications Warehouse

    Gonthier, Gerard

    2012-01-01

    An 80-foot-deep well (36Q397, U.S. Geological Survey site identification 320146081073701) was constructed at Hunter Army Airfield to assess the potential of using the surficial aquifer system as a water source to irrigate a ballfield complex. A 300-foot-deep test hole was drilled beneath the ballfield complex to characterize the lithology and water-bearing characteristics of sediments above the Upper Floridan aquifer. The test hole was then completed as well 36Q397 open to a 19-foot-thick shallow, confined sand unit contained within the surficial aquifer system. A single-well, 24-hour aquifer test was performed by pumping well 36Q397 at a rate of 50 gallons per minute during July 13-14, 2011, to characterize the hydrologic properties of the shallow, confined sand unit. Two pumping events prior to the aquifer test affected water levels. Drawdown during all three pumping events and residual drawdown during recovery periods were simulated using the Theis formula on multiple changes in discharge rate. Simulated drawdown and residual drawdown match well with measured drawdown and residual drawdown using values of horizontal hydraulic conductivity and specific storage, which are typical for a confined sand aquifer. Based on the hydrologic parameters used to match simulated drawdown and residual drawdown to measured drawdown and residual drawdown, the transmissivity of the sand was determined to be about 400 feet squared per day. The horizontal hydraulic conductivity of the sand was determined to be about 20 feet per day. Analysis of a water-quality sample indicated that the water is suitable for irrigation. Sample analysis indicated a calcium-carbonate type water having a total dissolved solids concentration of 39 milligrams per liter. Specific conductance and concentrations of all analyzed constituents were below those that would be a concern for irrigation, and were below primary and secondary water-quality criteria levels.

  17. Storm-damaged saline-contaminated boreholes as a means of aquifer contamination

    USGS Publications Warehouse

    Carlson, D.A.; Van Biersel, T. P.; Milner, L.R.

    2008-01-01

    Saline water from a storm surge can flow down storm-damaged submerged water supply wells and contaminate boreholes and surrounding aquifers. Using data from conventional purging techniques, aquifer test response analysis, chemical analysis, and regression analysis of chloride/silica (Cl/Si) ratio, equations were derived to estimate the volume of saline water intrusion into a well and a porous media aquifer, the volume of water needed to purge a well shortly following an intrusion event, and the volume of water needed after delay of several or more months, when the saline plume has expanded. Purging time required is a function of volume of water and pumping rate. The study site well is located within a shoreline community of Lake Pontchartrain, St. Tammany Parish, in southeastern Louisiana, United States, which was impacted by two hurricane storm surges and had neither been rehabilitated nor chlorinated prior to our study. Chemical analysis of water samples in fall 2005 and purging of well and aquifer in June 6, 2006, indicated saline water had intruded the well in 2005 and the well and aquifer in 2006. The volume of water needed to purge the study well was approximately 200 casing volumes, which is significantly greater than conventionally used during collection of water samples for water quality analyses. ?? 2007 National Ground Water Association.

  18. Hydrogeology and water quality of the Floridan aquifer system and effect of Lower Floridan aquifer withdrawals on the Upper Floridan aquifer at Barbour Pointe Community, Chatham County, Georgia, 2013

    USGS Publications Warehouse

    Gonthier, Gerard; Clarke, John S.

    2016-06-02

    Two test wells were completed at the Barbour Pointe community in western Chatham County, near Savannah, Georgia, in 2013 to investigate the potential of using the Lower Floridan aquifer as a source of municipal water supply. One well was completed in the Lower Floridan aquifer at a depth of 1,080 feet (ft) below land surface; the other well was completed in the Upper Floridan aquifer at a depth of 440 ft below land surface. At the Barbour Pointe test site, the U.S. Geological Survey completed electromagnetic (EM) flowmeter surveys, collected and analyzed water samples from discrete depths, and completed a 72-hour aquifer test of the Floridan aquifer system withdrawing from the Lower Floridan aquifer.Based on drill cuttings, geophysical logs, and borehole EM flowmeter surveys collected at the Barbour Pointe test site, the Upper Floridan aquifer extends 369 to 567 ft below land surface, the middle semiconfining unit, separating the two aquifers, extends 567 to 714 ft below land surface, and the Lower Floridan aquifer extends 714 to 1,056 ft below land surface.A borehole EM flowmeter survey indicates that the Upper Floridan and Lower Floridan aquifers each contain four water-bearing zones. The EM flowmeter logs of the test hole open to the entire Floridan aquifer system indicated that the Upper Floridan aquifer contributed 91 percent of the total flow rate of 1,000 gallons per minute; the Lower Floridan aquifer contributed about 8 percent. Based on the transmissivity of the middle semiconfining unit and the Floridan aquifer system, the middle semiconfining unit probably contributed on the order of 1 percent of the total flow.Hydraulic properties of the Upper Floridan and Lower Floridan aquifers were estimated based on results of the EM flowmeter survey and a 72-hour aquifer test completed in Lower Floridan aquifer well 36Q398. The EM flowmeter data were analyzed using an AnalyzeHOLE-generated model to simulate upward borehole flow and determine the transmissivity of water-bearing zones. Aquifer-test data were analyzed with a two-dimensional, axisymmetric, radial, transient, groundwater-flow model using MODFLOW–2005. The flowmeter-survey and aquifer-test simulations provided an estimated transmissivity of about 60,000 square feet per day for the Upper Floridan aquifer and about 5,000 square feet per day for the Lower Floridan aquifer.Water in discrete-depth samples collected from the Upper Floridan aquifer, middle semiconfining unit, and Lower Floridan aquifer during the EM flowmeter survey in August 2013 was low in dissolved solids. Tested constituents were in concentrations within established U.S. Environmental Protection Agency drinking water-quality criteria. Concentrations of measured constituents in water samples from Lower Floridan aquifer well 36Q398 collected at the end of the 72-hour aquifer test in November 2013 were generally higher than in the discrete-depth samples collected during EM flowmeter testing in August 2013 but remained within established drinking water-quality criteria.Water-level data for the aquifer test were filtered for external influences such as barometric pressure, earth-tide effects, and long-term trends to enable detection of small (less than 1 ft) water-level responses to aquifer-test withdrawal. During the 72-hour aquifer test, the Lower Floridan aquifer was pumped at a rate of 750 gallons per minute resulting in a drawdown response of 35.5 ft in the pumped well; 1.6 ft in the Lower Floridan aquifer observation well located about 6,000 ft west of the pumped well; and responses of 0.7, 0.6, and 0.4 ft in the Upper Floridan aquifer observation wells located about 36 ft, 6,000 ft, and 6,800 ft from the pumped well, respectively

  19. Innovative Field Methods for Characterizing the Hydraulic Properties of a Complex Fractured Rock Aquifer (Ploemeur, Brittany)

    NASA Astrophysics Data System (ADS)

    Bour, O.; Le Borgne, T.; Longuevergne, L.; Lavenant, N.; Jimenez-Martinez, J.; De Dreuzy, J. R.; Schuite, J.; Boudin, F.; Labasque, T.; Aquilina, L.

    2014-12-01

    Characterizing the hydraulic properties of heterogeneous and complex aquifers often requires field scale investigations at multiple space and time scales to better constrain hydraulic property estimates. Here, we present and discuss results from the site of Ploemeur (Brittany, France) where complementary hydrological and geophysical approaches have been combined to characterize the hydrogeological functioning of this highly fractured crystalline rock aquifer. In particular, we show how cross-borehole flowmeter tests, pumping tests and frequency domain analysis of groundwater levels allow quantifying the hydraulic properties of the aquifer at different scales. In complement, we used groundwater temperature as an excellent tracer for characterizing groundwater flow. At the site scale, measurements of ground surface deformation through long-base tiltmeters provide robust estimates of aquifer storage and allow identifying the active structures where groundwater pressure changes occur, including those acting during recharge process. Finally, a numerical model of the site that combines hydraulic data and groundwater ages confirms the geometry of this complex aquifer and the consistency of the different datasets. The Ploemeur site, which has been used for water supply at a rate of about 106 m3 per year since 1991, belongs to the French network of hydrogeological sites H+ and is currently used for monitoring groundwater changes and testing innovative field methods.

  20. Detailed performance and environmental monitoring of aquifer heating and cooling systems

    NASA Astrophysics Data System (ADS)

    Acuna, José; Ahlkrona, Malva; Zandin, Hanna; Singh, Ashutosh

    2016-04-01

    The project intends to quantify the performance and environmental impact of large scale aquifer thermal energy storage, as well as point at recommendations for operating and estimating the environmental footprint of future systems. Field measurements, test of innovative equipment as well as advanced modelling work and analysis will be performed. The following aspects are introduced and covered in the presentation: -Thermal, chemical and microbiological influence of akvifer thermal energy storage systems: measurement and evaluation of real conditions and the influence of one system in operation. -Follow up of energy extraction from aquifer as compared to projected values, recommendations for improvements. -Evaluation of the most used thermal modeling tool for design and calculation of groundwater temperatures, calculations with MODFLOW/MT3DMS -Test and evaluation of optical fiber cables as a way to measure temperatures in aquifer thermal energy storages

  1. Integrated assessment of future potential global change scenarios and their hydrological impacts in coastal aquifers - a new tool to analyse management alternatives in the Plana Oropesa-Torreblanca aquifer

    NASA Astrophysics Data System (ADS)

    Pulido-Velazquez, David; Renau-Pruñonosa, Arianna; Llopis-Albert, Carlos; Morell, Ignacio; Collados-Lara, Antonio-Juan; Senent-Aparicio, Javier; Baena-Ruiz, Leticia

    2018-05-01

    Any change in the components of the water balance in a coastal aquifer, whether natural or anthropogenic, can alter the freshwater-salt water equilibrium. In this sense climate change (CC) and land use and land cover (LULC) change might significantly influence the availability of groundwater resources in the future. These coastal systems demand an integrated analysis of quantity and quality issues to obtain an appropriate assessment of hydrological impacts using density-dependent flow solutions. The aim of this work is to perform an integrated analysis of future potential global change (GC) scenarios and their hydrological impacts in a coastal aquifer, the Plana Oropesa-Torreblanca aquifer. It is a Mediterranean aquifer that extends over 75 km2 in which important historical LULC changes have been produced and are planned for the future. Future CC scenarios will be defined by using an equi-feasible and non-feasible ensemble of projections based on the results of a multi-criteria analysis of the series generated from several regional climatic models with different downscaling approaches. The hydrological impacts of these CC scenarios combined with future LULC scenarios will be assessed with a chain of models defined by a sequential coupling of rainfall-recharge models, crop irrigation requirements and irrigation return models (for the aquifer and its neighbours that feed it), and a density-dependent aquifer approach. This chain of models, calibrated using the available historical data, allow testing of the conceptual approximation of the aquifer behaviour. They are also fed with series representatives of potential global change scenarios in order to perform a sensitivity analysis regarding future scenarios of rainfall recharge, lateral flows coming from the hydraulically connected neighbouring aquifer, agricultural recharge (taking into account expected future LULC changes) and sea level rise (SLR). The proposed analysis is valuable for improving our knowledge about the aquifer, and so comprises a tool to design sustainable adaptation management strategies taking into account the uncertainty in future GC conditions and their impacts. The results show that GC scenarios produce significant increases in the variability of flow budget components and in the salinity.

  2. Data for ground-water test hole near Zamora, Central Valley Aquifer Project, California

    USGS Publications Warehouse

    French, J.J.; Page, R.W.; Bertoldi, G.L.

    1982-01-01

    Preliminary data are presented for the first of seven test holes drilled as a part of the Central Valley Aquifer Project which is part of the National Regional Aquifer Systems Analysis Program. The test hole was drilled in the SW 1/4 SE 1/4 sec. 34, T. 12 N. , R. 1 E., Yolo County, California, about 3 miles northeast of the town of Zamora. Drilled to a depth of 2,500 feet below land surface, the hole is cased to a depth of 190 feet and equipped with three piezometer tubes to depths of 947, 1,401, and 2,125 feet. A 5-foot well screen is at the bottom of each piezometer. Eighteen cores and 68 sidewall cores were recovered. Laboratory tests were made for mineralogy, hydraulic conductivity, porosity , consolidation, grain-size distribution, Atterberg limits, X-ray diffraction, diatom identification, thermal conductivity, and chemical analysis of water. Geophysical and thermal gradient logs were made. The hole is sampled periodically for chemical analysis and measured for water level in the three tapped zones. This report presents methods used to obtain field samples, laboratory procedures, and the data obtained. (USGS)

  3. Hydrogeology and preliminary assessment of regional flow in the upper Cretaceous and adjacent aquifers in the northern Mississippi embayment

    USGS Publications Warehouse

    Brahana, J.V.; Mesko, T.O.

    1988-01-01

    On a regional scale, the groundwater system of the northern Mississippi embayment is composed of a series of nonindurated clastic sediments that overlie a thick sequence of Paleozoic carbonate, sandstones, and shales. The units that comprise the geohydrologic framework of this study are the alluvium-lower Wilcox Aquifer the Midway confining unit, the Upper Cretaceous aquifer, the Cretaceous-Paleozoic confining unit, and the Ozark-St. Francois aquifer. The Upper Cretaceous aquifer of Late Cretaceous age is the primary focus of this investigation; the study is part of the Gulf Coast Regional Aquifer-System Analysis. A four layer finite-difference groundwater flow model enabled testing of alternative boundary concepts and provide a refined definition of the hydrologic budget of the deep aquifers. The alluvium-lower Wilcox aquifer, the Upper Cretaceous aquifer, and the Ozark-St. Francois aquifer form layers 2 through 4, respectively. Layer 1 is an inactive layer of constant heads representing shallow water levels, which are a major control on recharge to and discharge from the regional system. A matrix of leakance values simulates each confining unit, allowing vertical interchange of water between different aquifers. The model was calibrated to 1980 conditions by using the assumption that 1980 was near steady-state conditions; it was calibrated to simulate observed heads were found to be most sensitive to pumping, and least sensitive to the leakance. By using all available water quality and water level data, alternative boundary conditions were tested by comparing model simulated heads to observed heads. The results of the early modeling effort also contribute to a better understanding of the regional hydrologic budget, indicating that: upward leakage from the Ozark-St. Francois aquifer to the Upper Cretaceous aquifer is about 43 cu ft/sec; upward recharge of about 68 cu ft/sec occurs to the lower Wilcox-alluvium aquifer from the Upper Cretaceous aquifer; and the Midway is an effective regional confining unit. (Author 's abstract)

  4. Assessment of Anaerobic Metabolic Activity and Microbial Diversity in a Petroleum-Contaminated Aquifer Using Push-Pull Tests in Combination With Molecular Tools and Stable Isotopes

    NASA Astrophysics Data System (ADS)

    Schroth, M. H.; Kleikemper, J.; Pombo, S. A.; Zeyer, J.

    2002-12-01

    In the past, studies on microbial communities in natural environments have typically focused on either their structure or on their metabolic function. However, linking structure and function is important for understanding microbial community dynamics, in particular in contaminated environments. We will present results of a novel combination of a hydrogeological field method (push-pull tests) with molecular tools and stable isotope analysis, which was employed to quantify anaerobic activities and associated microbial diversity in a petroleum-contaminated aquifer in Studen, Switzerland. Push-pull tests consisted of the injection of test solution containing a conservative tracer and reactants (electron acceptors, 13C-labeled carbon sources) into the aquifer anoxic zone. Following an incubation period, the test solution/groundwater mixture was extracted from the same location. Metabolic activities were computed from solute concentrations measured during extraction. Simultaneously, microbial diversity in sediment and groundwater was characterized by using fluorescence in situ hybridization (FISH), denaturing gradient gel electrophoresis (DGGE), as well as phospholipids fatty acid (PLFA) analysis in combination with 13C isotopic measurements. Results from DGGE analyses provided information on the general community structure before, during and after the tests, while FISH yielded information on active populations. Moreover, using 13C-labeling of microbial PLFA we were able to directly link carbon source assimilation in an aquifer to indigenous microorganisms while providing quantitative information on respective carbon source consumption.

  5. Effects from Unsaturated Zone Flow during Oscillatory Hydraulic Testing

    NASA Astrophysics Data System (ADS)

    Lim, D.; Zhou, Y.; Cardiff, M. A.; Barrash, W.

    2014-12-01

    In analyzing pumping tests on unconfined aquifers, the impact of the unsaturated zone is often neglected. Instead, desaturation at the water table is often treated as a free-surface boundary, which is simple and allows for relatively fast computation. Richards' equation models, which account for unsaturated flow, can be compared with saturated flow models to validate the use of Darcy's Law. In this presentation, we examine the appropriateness of using fast linear steady-periodic models based on linearized water table conditions in order to simulate oscillatory pumping tests in phreatic aquifers. We compare oscillatory pumping test models including: 1) a 2-D radially-symmetric phreatic aquifer model with a partially penetrating well, simulated using both Darcy's Law and Richards' Equation in COMSOL; and 2) a linear phase-domain numerical model developed in MATLAB. Both COMSOL and MATLAB models are calibrated to match oscillatory pumping test data collected in the summer of 2013 at the Boise Hydrogeophysical Research Site (BHRS), and we examine the effect of model type on the associated parameter estimates. The results of this research will aid unconfined aquifer characterization efforts and help to constrain the impact of the simplifying physical assumptions often employed during test analysis.

  6. Geohydrology and water quality of stratified-drift aquifers in the middle Merrimack River basin, south-central New Hampshire

    USGS Publications Warehouse

    Ayotte, Joseph D.; Toppin, Kenneth W.

    1995-01-01

    The U.S. Geological Survey, in cooperation with the State of New Hampshire, Department of Environmental Services, Water Resources Division has assessed the geohydrology and water quality of stratified-drift aquifers in the middle Merrimack River basin in south-central New Hampshire. The middle Merrimack River basin drains 469 square miles; 98 square miles is underlain by stratified-drift aquifers. Saturated thickness of stratified drift within the study area is generally less than 40 feet but locally greater than 100 feet. Transmissivity of stratified-drift aquifers is generally less than 2,000 feet squared per day but locally exceeds 6, 000 feet squared per day. At present (1990), ground-water withdrawals from stratified drift for public supply are about 0.4 million gallons per day within the basin. Many of the stratified-drift aquifers within the study area are not developed to their fullest potential. The geohydrology of stratified-drift aquifers was investigated by focusing on basic aquifer properties, including aquifer boundaries; recharge, discharge, and direction of ground-water flow; saturated thickness and storage; and transmissivity. Surficial geologic mapping assisted in the determination of aquifer boundaries. Data from 757 wells and test borings were used to produce maps of water-table altitude, saturated thickness, and transmissivity of stratified drift. More than 10 miles of seismic-refraction profiling and 14 miles of seismic-reflection profiling were also used to construct the water table and saturated-thickness maps. Stratified-drift aquifers in the southern, western, and central parts of the study area are typically small and discontinuous, whereas aquifers in the eastern part along the Merrimack River valley are continuous. The Merrimack River valley aquifers formed in glacial Lakes Merrimack and Hooksett. Many other smaller discontinuous aquifers formed in small temporary ponds during deglaciation. A stratified-drift aquifer in Goffstown was analyzed for aquifer yield by use of a two-dimensional, finite-difference ground-water-flow model. Yield of the Goffstown aquifer was estimated to be 2.5 million gallons per day. Sensitivity analysis showed that the estimate of aquifer yield was most sensitive to changes in hydraulic conductivity. The amount of water induced into the aquifer from the Piscataquog River was most affected by changes in estimates of streambed conductance. Results of analysis of water samples from 10 test wells indicate that, with some exceptions, water in the stratified-drift aquifers generally meets U.S. Environmental Protection Agency primary and secondary drinking-water regulations. Water from two wells had elevated sodium concentrations, waterfront two wells had elevated concentrations of dissolved iron, and waterfront seven wells had elevated concentrations of manganese. Known areas of contamination were avoided during water-quality sampling.

  7. Hydraulic characterization of volcanic rocks in Pahute Mesa using an integrated analysis of 16 multiple-well aquifer tests, Nevada National Security Site, 2009–14

    USGS Publications Warehouse

    Garcia, C. Amanda; Jackson, Tracie R.; Halford, Keith J.; Sweetkind, Donald S.; Damar, Nancy A.; Fenelon, Joseph M.; Reiner, Steven R.

    2017-01-20

    An improved understanding of groundwater flow and radionuclide migration downgradient from underground nuclear-testing areas at Pahute Mesa, Nevada National Security Site, requires accurate subsurface hydraulic characterization. To improve conceptual models of flow and transport in the complex hydrogeologic system beneath Pahute Mesa, the U.S. Geological Survey characterized bulk hydraulic properties of volcanic rocks using an integrated analysis of 16 multiple-well aquifer tests. Single-well aquifer-test analyses provided transmissivity estimates at pumped wells. Transmissivity estimates ranged from less than 1 to about 100,000 square feet per day in Pahute Mesa and the vicinity. Drawdown from multiple-well aquifer testing was estimated and distinguished from natural fluctuations in more than 200 pumping and observation wells using analytical water-level models. Drawdown was detected at distances greater than 3 miles from pumping wells and propagated across hydrostratigraphic units and major structures, indicating that neither faults nor structural blocks noticeably impede or divert groundwater flow in the study area.Consistent hydraulic properties were estimated by simultaneously interpreting drawdown from the 16 multiple-well aquifer tests with an integrated groundwater-flow model composed of 11 well-site models—1 for each aquifer test site. Hydraulic properties were distributed across volcanic rocks with the Phase II Pahute Mesa-Oasis Valley Hydrostratigraphic Framework Model. Estimated hydraulic-conductivity distributions spanned more than two orders of magnitude in hydrostratigraphic units. Overlapping hydraulic conductivity ranges among units indicated that most Phase II Hydrostratigraphic Framework Model units were not hydraulically distinct. Simulated total transmissivity ranged from 1,600 to 68,000 square feet per day for all pumping wells analyzed. High-transmissivity zones exceeding 10,000 square feet per day exist near caldera margins and extend along the northern and eastern Pahute Mesa study area and near the southwestern edge of the study area. The estimated hydraulic-property distributions and observed hydraulic connections among geologic structures improved the characterization and representation of groundwater flow at Pahute Mesa.

  8. Review of aquifer test results for the Lansdale area, Montgomery County, Pennsylvania, 1980-95

    USGS Publications Warehouse

    Goode, Daniel J.; Senior, Lisa A.

    1998-01-01

    Aquifer and aquifer-isolation test results in and around North Penn Area 6 Superfund site, Lansdale, Montgomery County, Pennsylvania are reviewed to provide estimated aquifer properties for use in a numerical model of ground-water flow. This review is in support of remedial action investigations by U.S. Environmental Protection Agency (USEPA), Region III, Philadelphia. Data are from files of the U.S. Geological Survey, USEPA, and water companies, and from unpublished consultant reports for USEPA and corporations in the Lansdale area. Tested wells are in fractured sedimentary rocks of the Brunswick Formation, which are Triassic-aged, dipping shales and sandstones. Review procedures include, in some cases, new analyses of drawdown during pumping and recovery using analytical models of flow to wells. Estimated aquifer transmissivities (T) range from zero to about 1,300 m2/d (meters squared per day), with most tests indicating T between 10 and 100 m2/d. Aquifer-isolation testing results indicate that most flow enters wells at a few discrete zones, probably fractures or bedding plane openings. The vertical connection between the zones in a single borehole with multiple producing zones often is negligible. This suggests that the formation is vertically anisotropic; the hydraulic conductivity is much larger in the horizontal direction than in the vertical direction. Some evidence of well-field-scale horizontal anisotropy exists, with maximum transmissivity aligned with the regional northeast strike of bedding, but this evidence is weak because of the small number of observation wells, particularly wells screened in isolated depth intervals. Analysis of recovery data after constant-pumping-rate aquifer tests and of drawdown during step tests suggests that a significant fraction, perhaps as much as 85 percent, of the drawdown in some production wells is due to well loss or skin effects in or very near the pumped well and is not caused by resistance to flow in the surrounding formations.

  9. Cyclic injection, storage, and withdrawal of heated water in a sandstone aquifer at St. Paul, Minnesota: Analysis of thermal data and nonisothermal modeling of short-term test cycles

    USGS Publications Warehouse

    Miller, Robert T.; Delin, G.N.

    1994-01-01

    A three-dimensional, anisotropic, nonisothermal, ground-water-flow, and thermal-energy-transport model was constructed to simulate the four short-term test cycles. The model was used to simulate the entire short-term testing period of approximately 400 days. The only model properties varied during model calibration were longitudinal and transverse thermal dispersivities, which, for final calibration, were simulated as 3.3 and 0.33 meters, respectively. The model was calibrated by comparing model-computed results to (1) measured temperatures at selected altitudes in four observation wells, (2) measured temperatures at the production well, and (3) calculated thermal efficiencies of the aquifer. Model-computed withdrawal-water temperatures were within an average of about 3 percent of measured values and model-computed aquifer-thermal efficiencies were within an average of about 5 percent of calculated values for the short-term test cycles. These data indicate that the model accurately simulated thermal-energy storage within the Franconia-Ironton-Galesville aquifer.

  10. Design, performance, and analysis of an aquifer thermal-energy-storage experiment using the doublet-well configuration

    NASA Astrophysics Data System (ADS)

    Molz, F. J.; Melville, J. G.; Gueven, O.; Parr, A. D.

    1983-09-01

    In March 1980 Auburn University began a series of aquifer thermal energy storage (ATES) experiments using the doublet well configuration. The test site was in Mobile, Alabama. The objectives of the three experimental cycles were to demonstrate the technical feasibility of the ATES concept, to identify and resolve operational problems, and to acquire a data base for developing and testing mathematical models. Pre-injection tests were performed and analyses of hydraulic, geochemical, and thermodynamic data were completed. Three injection-storage-recovery cycles had injection volumes of 25,402 m(3), 58,010 m(3), and 58,680 m(3) and average injection temperatures of 58.50C, 81.00C. and 79.00C, respectively. The first cycle injection began in February 1981 and the third cycle recovery was completed in November 1982. Attributable to the doublet well configuration no clogging of injection wells occurred. Energy recovery percentages based on recovery volumes equal to the injection volumes were 56, 45, and 42%. Thermal convection effects were observed. Aquifer nonhomogeneity, not detectable using standard aquifer testing procedures, was shown to reduce recovery efficiency.

  11. Water-quality assessment of the Trinity River basin, Texas : ground-water quality of the Trinity, Carrizo-Wilcox, and Gulf Coast aquifers, February-August 1994

    USGS Publications Warehouse

    Reutter, David C.; Dunn, David D.

    2000-01-01

    Ground-water samples were collected from wells in the outcrops of the Trinity, Carrizo-Wilcox, and Gulf Coast aquifers during February-August 1994 to determine the quality of ground water in the three major aquifers in the Trinity River Basin study unit, Texas. These samples were collected and analyzed for selected properties, nutrients, major inorganic constituents, trace elements, pesticides, dissolved organic carbon, total phenols, methylene blue active substances, and volatile organic compounds as part of the U.S. Geological Survey National Water-Quality Assessment Program. Quality-control practices included the collection and analysis of blank, duplicate, and spiked samples. Samples were collected from 12 shallow wells (150 feet or less) and from 12 deep wells (greater than 150 feet) in the Trinity aquifer, 11 shallow wells and 12 deep wells in the Carrizo-Wilcox aquifer, and 14 shallow wells and 10 deep wells in the Gulf Coast aquifer. The three aquifers had similar water chemistries-calcium was the dominant cation and bicarbonate the dominant anion. Statistical tests relating well depths to concentrations of nutrients and major inorganic constituents indicated correlations between well depth and concentrations of ammonia nitrogen, nitrite plus nitrate nitrogen, bicarbonate, sodium, and dissolved solids in the Carrizo-Wilcox aquifer and between well depth and concentrations of sulfate in the Gulf Coast aquifer. The tests indicated no significant correlations for the Trinity aquifer. Concentrations of dissolved solids were larger than the secondary maximum contaminant level of 500 milligrams per liter established for drinking water by the U.S. Environmental Protection Agency in 12 wells in the Trinity aquifer, 4 wells in the Carrizo-Wilcox aquifer, and 6 wells in the Gulf Coast aquifer. Iron concentrations were larger than the secondary maximum contaminant level of 300 micrograms per liter in at least 3 samples from each aquifer, and manganese concentrations were larger than the secondary maximum contaminant level of 50 micrograms per liter in at least 2 samples from each aquifer. The pesticides atrazine, deethylatrazine, and pp'-DDE were detected in at least one sample from each aquifer. Diazinon was detected in 11 Trinity aquifer samples and 4 Carrizo-Wilcox aquifer samples. Each aquifer had one detection of a volatile organic compound-benzene in the Trinity aquifer, trichlorofluoromethane in the Carrizo-Wilcox aquifer, and trichloromethane in the Gulf Coast aquifer.

  12. A cross-site comparison of methods used for hydrogeologic characterization of the Galena-Platteville aquifer in Illinois and Wisconsin, with examples from selected Superfund sites

    USGS Publications Warehouse

    Kay, Robert T.; Mills, Patrick C.; Dunning, Charles P.; Yeskis, Douglas J.; Ursic, James R.; Vendl, Mark

    2004-01-01

    The effectiveness of 28 methods used to characterize the fractured Galena-Platteville aquifer at eight sites in northern Illinois and Wisconsin is evaluated. Analysis of government databases, previous investigations, topographic maps, aerial photographs, and outcrops was essential to understanding the hydrogeology in the area to be investigated. The effectiveness of surface-geophysical methods depended on site geology. Lithologic logging provided essential information for site characterization. Cores were used for stratigraphy and geotechnical analysis. Natural-gamma logging helped identify the effect of lithology on the location of secondary- permeability features. Caliper logging identified large secondary-permeability features. Neutron logs identified trends in matrix porosity. Acoustic-televiewer logs identified numerous secondary-permeability features and their orientation. Borehole-camera logs also identified a number of secondary-permeability features. Borehole ground-penetrating radar identified lithologic and secondary-permeability features. However, the accuracy and completeness of this method is uncertain. Single-point-resistance, density, and normal resistivity logs were of limited use. Water-level and water-quality data identified flow directions and indicated the horizontal and vertical distribution of aquifer permeability and the depth of the permeable features. Temperature, spontaneous potential, and fluid-resistivity logging identified few secondary-permeability features at some sites and several features at others. Flowmeter logging was the most effective geophysical method for characterizing secondary-permeability features. Aquifer tests provided insight into the permeability distribution, identified hydraulically interconnected features, the presence of heterogeneity and anisotropy, and determined effective porosity. Aquifer heterogeneity prevented calculation of accurate hydraulic properties from some tests. Different methods, such as flowmeter logging and slug testing, occasionally produced different interpretations. Aquifer characterization improved with an increase in the number of data points, the period of data collection, and the number of methods used.

  13. Letter Report: Stable Hydrogen and Oxygen Isotope Analysis of B-Complex Perched Water Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Brady D.; Moran, James J.; Nims, Megan K.

    Fine-grained sediments associated with the Cold Creek Unit at Hanford have caused the formation of a perched water aquifer in the deep vadose zone at the B Complex area, which includes waste sites in the 200-DV-1 Operable Unit and the single-shell tank farms in Waste Management Area B-BX-BY. High levels of contaminants, such as uranium, technetium-99, and nitrate, make this aquifer a continuing source of contamination for the groundwater located a few meters below the perched zone. Analysis of deuterium ( 2H) and 18-oxygen ( 18O) of nine perched water samples from three different wells was performed. Samples represent timemore » points from hydraulic tests performed on the perched aquifer using the three wells. The isotope analyses showed that the perched water had δ 2H and δ 18O ratios consistent with the regional meteoric water line, indicating that local precipitation events at the Hanford site likely account for recharge of the perched water aquifer. Data from the isotope analysis can be used along with pumping and recovery data to help understand the perched water dynamics related to aquifer size and hydraulic control of the aquifer in the future.« less

  14. Aquifer test to determine hydraulic properties of the Elm aquifer near Aberdeen, South Dakota

    USGS Publications Warehouse

    Schaap, Bryan D.

    2000-01-01

    The Elm aquifer, which consists of sandy and gravelly glacial-outwash deposits, is present in several counties in northeastern South Dakota. An aquifer test was conducted northeast of Aberdeen during the fall of 1999 to determine the hydraulic properties of the Elm aquifer in that area. An improved understanding of the properties of the aquifer will be useful in the possible development of the aquifer as a water resource. Historical water-level data indicate that the saturated thickness of the Elm aquifer can change considerably over time. From September 1977 through November 1985, water levels at three wells completed in the Elm aquifer near the aquifer test site varied by 5.1 ft, 9.50 ft, and 11.1 ft. From June 1982 through October 1999, water levels at five wells completed in the Elm aquifer near the aquifer test site varied by 8.7 ft, 11.4 ft, 13.2 ft, 13.8 ft, and 19.7 ft. The water levels during the fall of 1999 were among the highest on record, so the aquifer test was affected by portions of the aquifer being saturated that might not be saturated during drier times. The aquifer test was conducted using five existing wells that had been installed prior to this study. Well A, the pumped well, has an operating irrigation pump and is centrally located among the wells. Wells B, C, D, and E are about 70 ft, 1,390 ft, 2,200 ft, and 3,100 ft, respectively, in different directions from Well A. Using vented pressure transducers and programmable data loggers, water-level data were collected at the five wells prior to, during, and after the pumping, which started on November 19, 1999, and continued a little over 72 hours. Based on available drilling logs, the Elm aquifer near the test area was assumed to be unconfined. The Neuman (1974) method theoretical response curves that most closely match the observed water-level changes at Wells A and B were calculated using software (AQTESOLV for Windows Version 2.13-Professional) developed by Glenn M. Duffield of HydroSOLVE, Inc. These best fit theoretical response curves are based on a transmissivity of 24,000 ft2/d or a hydraulic conductivity of about 600 ft/d, a storage coefficient of 0.05, a specific yield of 0.42, and vertical hydraulic conductivity equal to horizontal hydraulic conductivity. The theoretical type curves match the observed data fairly closely at Wells A and B until about 2,500 minutes and 1,000 minutes, respectively, after pumping began. The increasing rate of drawdown after these breaks is an indication that a no-flow boundary (an area with much lower hydraulic conductivity) likely was encountered and that Wells A and B may be completed in a part of the Elm aquifer with limited hydraulic connection to the rest of the aquifer. Additional analysis indicates that if different assumptions regarding the screened interval for Well B and aquifer anisotropy are used, type curves can be calculated that fit the observed data using a lower specific yield that is within the commonly accepted range. When the screened interval for Well B was reduced to 5 ft near the top of the aquifer and horizontal hydraulic conductivity was set to 20 times vertical hydraulic conductivity, the type curves calculated using a specific yield of 0.1 and a transmissivity of 30,200 ft2/d also matched the observed data from Wells A and B fairly well. A version of the Theim equilibrium equation was used to calculate the theoretical drawdown in an idealized unconfined aquifer when a perfectly efficient well is being pumped at a constant rate. These calculations were performed for a range of pumping rates, drawdowns at the wells, and distances between wells that might be found in a production well field in the Elm aquifer. Although the aquifer test indicates that hydraulic conductivity near the well may be adequate to support a production well, the comparison of drawdown and recovery curves indicates the possibility that heterogeneities may limit the productive capacity of specific loca

  15. Hydrology of the Claiborne aquifer and interconnection with the Upper Floridan aquifer in southwest Georgia

    USGS Publications Warehouse

    Gordon, Debbie W.; Gonthier, Gerard

    2017-04-24

    The U.S. Geological Survey conducted a study, in cooperation with the Georgia Environmental Protection Division, to define the hydrologic properties of the Claiborne aquifer and evaluate its connection with the Upper Floridan aquifer in southwest Georgia. The effort involved collecting and compiling hydrologic data from the aquifer in subarea 4 of southwestern Georgia. Data collected for this study include borehole geophysical logs in 7 wells, and two 72-hour aquifer tests to determine aquifer properties.The top of the Claiborne aquifer extends from an altitude of about 200 feet above the North American Vertical Datum of 1988 (NAVD 88) in Terrell County to 402 feet below NAVD 88 in Decatur County, Georgia. The base of the aquifer extends from an altitude of about 60 feet above NAVD 88 in eastern Sumter County to about 750 feet below NAVD 88 in Decatur County. Aquifer thickness ranges from about 70 feet in eastern Early County to 400 feet in Decatur County.The transmissivity of the Claiborne aquifer, determined from two 72-hour aquifer tests, was estimated to be 1,500 and 700 feet squared per day in Mitchell and Early Counties, respectively. The storage coefficient was estimated to be 0.0006 and 0.0004 for the same sites, respectively. Aquifer test data from Mitchell County indicate a small amount of leakage occurred during the test. Groundwater-flow models suggest that the source of the leakage was the underlying Clayton aquifer, which produced about 2.5 feet of drawdown in response to pumping in the Claiborne aquifer. The vertical hydraulic conductivity of the confining unit between the Claiborne and Clayton aquifers was simulated to be about 0.02 foot per day.Results from the 72-hour aquifer tests run for this study indicated no interconnection between the Claiborne and overlying Upper Floridan aquifers at the two test sites. Additional data are needed to monitor the effects that increased withdrawals from the Claiborne aquifer may have on future water resources.

  16. Data for ground-water test hole near Butte City, Central Valley aquifer project, California

    USGS Publications Warehouse

    French, James J.; Page, R.W.; Bertoldi, G.L.

    1983-01-01

    This report provides preliminary data for the third of seven test holes drilled as part of the Central Valley Aquifer Project which is part of the National Regional Aquifer Systems Analysis Program. The test hole was drilled in the SW 1/4 NE 1/4 sec. 32, T. 19 N., R. 1 W., Glenn County, California, about one-half mile south of the town of Butte City. Drilled to a depth of 1,432 feet below land surface, the hole is cased to a depth of 82 feet and equipped with three piezometer tubes to depths of 592 feet, 968 feet, and 1,330 feet. A 5-foot well screen is at the bottom of each piezometer. Each screened interval has a cement plug above and below it to isolate it from other parts of the aquifer , and the well bore is filled between the plugs with sediment. Nine cores and 49 sidewall cores were recovered. Laboratory tests were made for mineralogy, hydraulic conductivity, porosity , consolidation, grain-size distribution, Atterberg limits, X-ray diffraction, and chemical quality of water. Geophysical and thermal gradient logs were made. The hole is sampled periodically for chemical analysis and measured for water level in the three tapped zones. This report presents methods used to obtain field samples, laboratory procedures, and the data obtained. (USGS)

  17. Hydrochemical analysis of groundwater using a tree-based model

    NASA Astrophysics Data System (ADS)

    Litaor, M. Iggy; Brielmann, H.; Reichmann, O.; Shenker, M.

    2010-06-01

    SummaryHydrochemical indices are commonly used to ascertain aquifer characteristics, salinity problems, anthropogenic inputs and resource management, among others. This study was conducted to test the applicability of a binary decision tree model to aquifer evaluation using hydrochemical indices as input. The main advantage of the tree-based model compared to other commonly used statistical procedures such as cluster and factor analyses is the ability to classify groundwater samples with assigned probability and the reduction of a large data set into a few significant variables without creating new factors. We tested the model using data sets collected from headwater springs of the Jordan River, Israel. The model evaluation consisted of several levels of complexity, from simple separation between the calcium-magnesium-bicarbonate water type of karstic aquifers to the more challenging separation of calcium-sodium-bicarbonate water type flowing through perched and regional basaltic aquifers. In all cases, the model assigned measures for goodness of fit in the form of misclassification errors and singled out the most significant variable in the analysis. The model proceeded through a sequence of partitions providing insight into different possible pathways and changing lithology. The model results were extremely useful in constraining the interpretation of geological heterogeneity and constructing a conceptual flow model for a given aquifer. The tree model clearly identified the hydrochemical indices that were excluded from the analysis, thus providing information that can lead to a decrease in the number of routinely analyzed variables and a significant reduction in laboratory cost.

  18. Hydrogeology of the Judith River Formation in southwestern Saskatchewan, Canada

    NASA Astrophysics Data System (ADS)

    Ferris, David; Lypka, Morgan; Ferguson, Grant

    2017-11-01

    The Judith River Formation forms an important regional aquifer in southwestern Saskatchewan, Canada. This aquifer is used for domestic and agricultural purposes in some areas and supports oil and gas production in other areas. As a result, the available data come from a range of sources and integration is required to provide an overview of aquifer characteristics. Here, data from oil and gas databases are combined with data from groundwater resource assessments. Analysis of cores, drill-stem tests and pumping tests provide a good overview of the physical hydrogeology of the Judith River Aquifer. Water chemistry data from oil and gas databases were less helpful in understanding the chemical hydrogeology due contamination of samples and unreliable laboratory analyses. Analytical modeling of past pumping in the aquifer indicates that decreases in hydraulic head exceeding 2 m are possible over distances of 10s of kilometers. Similar decreases in head should be expected for additional large withdrawals of groundwater from the Judith River Aquifer. Long-term groundwater abstraction should be limited by low pumping rates. Higher pumping rates appear to be possible for short-term uses, such as those required by the oil and gas industry.

  19. WTAQ version 2-A computer program for analysis of aquifer tests in confined and water-table aquifers with alternative representations of drainage from the unsaturated zone

    USGS Publications Warehouse

    Barlow, Paul M.; Moench, Allen F.

    2011-01-01

    The computer program WTAQ simulates axial-symmetric flow to a well pumping from a confined or unconfined (water-table) aquifer. WTAQ calculates dimensionless or dimensional drawdowns that can be used with measured drawdown data from aquifer tests to estimate aquifer hydraulic properties. Version 2 of the program, which is described in this report, provides an alternative analytical representation of drainage to water-table aquifers from the unsaturated zone than that which was available in the initial versions of the code. The revised drainage model explicitly accounts for hydraulic characteristics of the unsaturated zone, specifically, the moisture retention and relative hydraulic conductivity of the soil. The revised program also retains the original conceptualizations of drainage from the unsaturated zone that were available with version 1 of the program to provide alternative approaches to simulate the drainage process. Version 2 of the program includes all other simulation capabilities of the first versions, including partial penetration of the pumped well and of observation wells and piezometers, well-bore storage and skin effects at the pumped well, and delayed drawdown response of observation wells and piezometers.

  20. Simple method for quick estimation of aquifer hydrogeological parameters

    NASA Astrophysics Data System (ADS)

    Ma, C.; Li, Y. Y.

    2017-08-01

    Development of simple and accurate methods to determine the aquifer hydrogeological parameters was of importance for groundwater resources assessment and management. Aiming at the present issue of estimating aquifer parameters based on some data of the unsteady pumping test, a fitting function of Theis well function was proposed using fitting optimization method and then a unitary linear regression equation was established. The aquifer parameters could be obtained by solving coefficients of the regression equation. The application of the proposed method was illustrated, using two published data sets. By the error statistics and analysis on the pumping drawdown, it showed that the method proposed in this paper yielded quick and accurate estimates of the aquifer parameters. The proposed method could reliably identify the aquifer parameters from long distance observed drawdowns and early drawdowns. It was hoped that the proposed method in this paper would be helpful for practicing hydrogeologists and hydrologists.

  1. Transient well flow in leaky multiple-aquifer systems

    NASA Astrophysics Data System (ADS)

    Hemker, C. J.

    1985-10-01

    A previously developed eigenvalue analysis approach to groundwater flow in leaky multiple aquifers is used to derive exact solutions for transient well flow problems in leaky and confined systems comprising any number of aquifers. Equations are presented for the drawdown distribution in systems of infinite extent, caused by wells penetrating one or more of the aquifers completely and discharging each layer at a constant rate. Since the solution obtained may be regarded as a combined analytical-numerical technique, a type of one-dimensional modelling can be applied to find approximate solutions for several complicating conditions. Numerical evaluations are presented as time-drawdown curves and include effects of storage in the aquitard, unconfined conditions, partially penetrating wells and stratified aquifers. The outcome of calculations for relatively simple systems compares very well with published corresponding results. The proposed multilayer solution can be a valuable tool in aquifer test evaluation, as it provides the analytical expression required to enable the application of existing computer methods to the determination of aquifer characteristics.

  2. Performance evaluation testing of wells in the gradient control system at a federally operated Confined Disposal Facility using single well aquifer tests, East Chicago, Indiana

    USGS Publications Warehouse

    Lampe, David C.; Unthank, Michael D.

    2016-12-08

    The U.S. Geological Survey (USGS) performed tests to evaluate the hydrologic connection between the open interval of the well and the surrounding Calumet aquifer in response to fouling of extraction well pumps onsite. Two rounds of air slug testing were performed on seven monitoring wells and step drawdown and subsequent recovery tests on three extraction wells on a U.S. Army Corps of Engineers Confined Disposal Facility (CDF) in East Chicago, Indiana. The wells were tested in 2014 and again in 2015. The extraction and monitoring wells are part of the gradient control system that establishes an inward gradient around the perimeter of the facility. The testing established a set of protocols that site personnel can use to evaluate onsite well integrity and develop a maintenance procedure to evaluate future well performance.The results of the slug test analysis data indicate that the hydraulic connection of the well screen to the surrounding aquifer material in monitoring wells on the CDF and the reliability of hydraulic conductivity estimates of the surrounding geologic media could be increased by implementing well development maintenance. Repeated air slug tests showed increasing hydraulic conductivity until, in the case of the monitoring wells located outside of the groundwater cutoff wall (MW–4B, MW–11B, MW–14B), the difference in hydraulic conductivity from test to test decreased, indicating the results were approaching the optimal hydraulic connection between the aquifer and the well screen. Hydraulic conductivity values derived from successive tests in monitoring well D40, approximately 0.25 mile south of the CDF, were substantially higher than those derived from wells on the CDF property. Also, values did not vary from test to test like those measured in monitoring wells located on the CDF property, which indicated that a process may be affecting the connectivity of the wells on the CDF property to the Calumet aquifer. Derived hydraulic conductivity values from the initial air slug test during the 2015 testing period for MW–11A and MW–14A are an order of magnitude less than those derived from the final test during the 2014 testing period indicating the development of a low conductivity skin between the final test of the 2014 testing period and the beginning of the 2015 testing period that created a decrease in the connection of the monitoring well screen to the surrounding aquifer material.Repeated step drawdown and recovery testing of the extraction wells tested during this study provided results that indicate a slight increase in the development of a skin and a decrease in the connectivity of the extraction wells with the Calumet aquifer. Hydraulic conductivity values obtained from the test results were relatively similar in EW–4B and EW–14A but were substantially lower for EW–11C. This difference may be due to the presence of finer grained silt deposits in the area surrounding well nest 11. Skin factors calculated during the step drawdown and recovery analysis were lowest in EW–11C and relatively similar in EW–4B and EW–14A. Calculated skin factors increased slightly in the analysis of data collected in 2015 from that collected in 2014.Comparisons of the specific-capacity values calculated from well development data collected following extraction well installation to those calculated during the single well aquifer tests at EW–4B, EW–14A and EW–11C indicate that the productivity of extraction wells on the CDF property has diminished since 2008. Values calculated for monitoring wells MW–4A, MW–11A, and MW–14A were used to evaluate the decrease in air slug derived hydraulic conductivity for monitoring wells within the groundwater cutoff wall between testing in 2014 and 2015.Results from testing by this study indicate that implementation of an air slug testing regimen of the monitoring wells that control the gradient control system at the CDF throughout the course of a year may help sustain the connectivity between the monitoring wells and the surrounding aquifer and provide data to evaluate the need for different types of well development approaches to address chemical or biological fouling issues. Repeated step drawdown and recovery testing of the extraction wells tested during this study provided results that indicate a slight increase in the development of a skin and a decrease in the connectivity of the extraction wells with the Calumet aquifer. Implementation of a specific capacity testing regimen can provide data to record and track well condition through time for individual extraction wells. Results from aquifer testing by this study indicate that specific capacity test results, when paired with recovery testing, provide useful data to measure the development of any low conductivity wellbore skin through the skin factors derived for the individual extraction wells. An initial annual schedule of specific capacity and recovery tests would provide sufficient data to identify substantial short-term changes in the operating condition of the extraction wells.

  3. Summary of hydrologic testing of the Floridan aquifer system at Hunter Army Airfield, Chatham County, Georgia

    USGS Publications Warehouse

    Williams, Lester J.

    2010-01-01

    A 1,168-foot deep test well was completed at Hunter Army Airfield in the summer of 2009 to investigate the potential of using the Lower Floridan aquifer as a source of water supply to satisfy increased needs as a result of base expansion and increased troop levels. The U.S. Geological Survey conducted hydrologic testing at the test site including flowmeter surveys, packer-slug tests, and aquifer tests of the Upper and Lower Floridan aquifers. Flowmeter surveys were completed at different stages of well construction to determine the depth and yield of water-bearing zones and to identify confining beds that separate the main producing aquifers. During a survey when the borehole was open to both the upper and lower aquifers, five water-bearing zones in the Upper Floridan aquifer supplied 83.5 percent of the total pumpage, and five water-bearing zones in the Lower Floridan aquifer supplied the remaining 16.5 percent. An upward gradient was indicated from the ambient flowmeter survey: 7.6 gallons per minute of groundwater was detected entering the borehole between 750 and 1,069 feet below land surface, then moved upward, and exited the borehole into lower-head zones between 333 and 527 feet below land surface. During a survey of the completed Lower Floridan well, six distinct water-producing zones were identified; one 17-foot-thick zone at 768-785 feet below land surface yielded 47.9 percent of the total pumpage while the remaining five zones yielded between 2 and 15 percent each. The thickness and hydrologic properties of the confining unit separating the Upper and Lower Floridan aquifers were determined from packer tests and flowmeter surveys. This confining unit, which is composed of rocks of Middle Eocene age, is approximately 160 feet thick with horizontal hydraulic conductivities determined from four slug tests to range from 0.2 to 3 feet per day. Results of two separate slug tests within the middle confining unit were both 2 feet per day. Aquifer testing indicated the Upper Floridan aquifer had a transmissivity of 40,000 feet squared per day, and the Lower Floridan aquifer had a transmissivity of 10,000 feet squared per day. An aquifer test conducted on the combined aquifer system, when the test well was open from 333 to 1,112 feet, gave a transmissivity of 50,000 feet squared per day. Additionally, during the 72-hour test of the Lower Floridan aquifer, a drawdown response was observed in the Upper Floridan aquifer wells.

  4. Field Investigation of Stream-Aquifer Interactions: A Case Study in Coastal California

    NASA Astrophysics Data System (ADS)

    Pritchard-Peterson, D.; Malama, B.

    2017-12-01

    We report here results of a detailed investigation of the dynamic interaction between a stream and an alluvial aquifer at Swanton Pacific Ranch in the Scotts Creek watershed, Santa Cruz County, California. The aquifer is an important source of groundwater for cropland irrigation and for aquatic ecosystem support. Low summer base flows in Scotts Creek are a source of serious concern for land managers, fisheries biologists, and regulatory agencies due to the presence of federally protected steelhead trout and coho salmon. An understanding of the interaction between the stream and pumped aquifer will allow for assessment of the impacts of groundwater extraction on stream flows and is essential to establishing minimum flow requirements. This will aid in the development of sustainable riparian groundwater pumping practices that meet agricultural and ecological needs. Results of extensive direct-push sampling of the subsurface, laboratory falling-head permeameter tests and particle size analysis of aquifer sediments, multi-day pumping tests, long-term passive monitoring of aquifer hydraulic heads and stream stage and discharge, and electrical resistivity interrogation of the subsurface are reported here. Findings indicate that the permeable subsurface formation tapped by irrigation wells is a leaky semi-confined aquifer, overlain by a thin low permeability layer of silt and clay above which lies Scotts Creek. These results are particularly useful to land managers responsible for groundwater abstraction from wells that tap into the aquifer. Additionally, an index of stream-aquifer connectivity is proposed that would allow land managers to conveniently modify groundwater abstraction practices, minimizing concerns of stream depletion.

  5. Transient well flow in layered aquifer systems: the uniform well-face drawdown solution

    NASA Astrophysics Data System (ADS)

    Hemker, C. J.

    1999-11-01

    Previously a hybrid analytical-numerical solution for the general problem of computing transient well flow in vertically heterogeneous aquifers was proposed by the author. The radial component of flow was treated analytically, while the finite-difference technique was used for the vertical flow component only. In the present work the hybrid solution has been modified by replacing the previously assumed uniform well-face gradient (UWG) boundary condition in such a way that the drawdown remains uniform along the well screen. The resulting uniform well-face drawdown (UWD) solution also includes the effects of a finite diameter well, wellbore storage and a thin skin, while partial penetration and vertical heterogeneity are accommodated by the one-dimensional discretization. Solutions are proposed for well flow caused by constant, variable and slug discharges. The model was verified by comparing wellbore drawdowns and well-face flux distributions with published numerical solutions. Differences between UWG and UWD well flow will occur in all situations with vertical flow components near the well, which is demonstrated by considering: (1) partially penetrating wells in confined aquifers, (2) fully penetrating wells in unconfined aquifers with delayed response and (3) layered aquifers and leaky multiaquifer systems. The presented solution can be a powerful tool for solving many well-hydraulic problems, including well tests, flowmeter tests, slug tests and pumping tests. A computer program for the analysis of pumping tests, based on the hybrid analytical-numerical technique and UWG or UWD conditions, is available from the author.

  6. The surficial aquifer in east-central St Johns County, Florida

    USGS Publications Warehouse

    Hayes, Eugene C.

    1981-01-01

    The surficial aquifer, a composite of confined and unconfined water-bearing zones overlying the Miocene Hawthorn Formation, is an important source of water in St. Johns County, Fla. The water from wells open to the surficial aquifer generally meets quality standards recommended by the U.S. Environmental Protection Agency for public water supplies, except for concentrations of iron that for most wells are substantially greater than the recommended limit of 0.3 milligrams per liter. Data from 12 test wells drilled to the top of the Hawthorn formation, about 100 feet below land surface, indicate that the productive zones and confining beds in the surficial aquifer are discontinuous. Test well yields from individual zones range from less than 1 to 42 gallons per minute from depths between 20 and 100 feet below land surface. The most productive zones were generally found in the Tillman Ridge area, about 10 square miles in the west-central part of the area of investigation. Analysis of an aquifer test on a well in the Tillman Ridge area indicates a transmissivity of about 6,500 to 7,000 feet squared per day. The best local source of good quality water for development of a relatively large water supply is in the vicinity of Tillman Ridge. (USGS)

  7. Using dye tracing to establish groundwater flow paths in a limestone marble aquifer, University of California, Santa Cruz, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayes, J.; Bertschinger, V.; Aley, T.

    1993-04-01

    Areas underlain by karst aquifers are characterized by soluble rock with sinkholes, caves, and a complex underground drainage network. Groundwater issues such as flow direction, well pumping impacts, spring recharge areas, and potential contamination transport routes are greatly complicated by the unique structure of karst aquifers. Standard aquifer analysis techniques cannot be applied unless the structure of the karst aquifer is understood. Water soluble fluorescent dyes are a powerful tool for mapping the irregular subsurface connections and flow paths in karst aquifers. Mapping the subsurface connections allows reasonable estimates of the hydrologic behavior of the aquifer. Two different fluorescent dyesmore » were injected at two points in a limestone karst aquifer system beneath the University of California, Santa Cruz campus. Flow paths in the marble were thought to be closely tied to easily recognized geomorphic alignments of sinkholes associated with fault and fracture zones. The dye tests revealed unexpected and highly complex interconnections. These complex flow paths only partially corresponded to previous surface mapping and aerial photo analysis of fracture systems. Several interfingering but hydrologically unconnected flow paths evidently exist within the cavernous aquifer. For example, dye did not appear at some discharge springs close to the dye injection points, but did appear at more distant springs. This study shows how a dye tracing study in a small, well-defined limestone body can shed light on a variety of environmental and hydrological issues, including potential well pumping impact areas, wellhead protection and recharge areas, parking lot runoff injection to aquifers, and drainage routes from hazardous materials storage areas.« less

  8. Geology and hydrogeology of Naval Air Station Chase Field and Naval Auxiliary Landing Field Goliad, Bee and Goliad counties, Texas

    USGS Publications Warehouse

    Snyder, G.L.

    1995-01-01

    Large vertical hydraulic-head gradients are present between the unconfined Evangeline aquifer and confined Fleming aquifers at Naval Air Station Chase Field and Naval Auxiliary Landing Field Goliad. These gradients, together with the results of the aquifer test at Naval Air Station Chase Field and assumed characteristics of the confining units, indicate that downward flow of ground water probably occurs from the water-table aquifer to the underlying aquifers. The rate of downward flow between the two confined Fleming aquifers (from A-sand to B-sand) can be approximated using an estimate of vertical hydraulic conductivity of the intervening confining unit obtained from assumed storage characteristics and data from the aquifer test. Under the relatively high vertical hydraulic-head gradient induced by the aquifer test, ground-water movement from the A-sand aquifer to the B-sand aquifer could require about 490 years; and about 730 years under the natural gradient. Future increases in ground-water withdrawals from the B-sand aquifer might increase downward flow in the aquifer system of the study area.

  9. Groundwater conditions and studies in the Augusta–Richmond County area, Georgia, 2008–2009

    USGS Publications Warehouse

    Gonthier, Gerard; Lawrence, Stephen J.; Peck, Michael F.; Holloway, O. Gary

    2011-01-01

    Groundwater studies and monitoring efforts conducted during 2008–2009, as part of the U.S. Geological Survey (USGS) Cooperative Water Program with the City of Augusta in Richmond County, Georgia, provided data for the effective management of local water resources. During 2008–2009 the USGS completed: (1) installation of three monitoring wells and the collection of lithologic and geophysical logging data to determine the extent of hydrogeologic units, (2) collection of continuous groundwater-level data from wells near Well Fields 2 and 3, (3) collection of synoptic groundwater-level measurements and construction of potentiometric-surface maps in Richmond County to establish flow gradients and groundwater-flow directions in the Dublin and Midville aquifer systems, (4) completion of a 24-hour aquifer test to determine hydraulic characteristics of the lower Dublin aquifer, and upper and lower Midville aquifers in Well Field 2, and (5) collection of groundwater samples from selected wells in Well Field 2 for laboratory analysis of volatile organic compounds and groundwater tracers to assess groundwater quality and estimate the time of groundwater recharge. Potentiometric-surface maps of the Dublin and Midville aquifer systems for 2008–2009 indicate that the general groundwater flow direction within Richmond County is eastward toward the Savannah River, with the exception of the area around Well Field 2, where pumping interrupts the eastward flow of water toward the Savannah River and causes flow lines to bend toward the center of pumping. Results from a 24-hour aquifer test conducted in 2009 within the upper and lower Midville aquifers at Well Field 2 indicated a transmissivity and storativity for the upper and lower Midville aquifers, combined, of 4,000 feet-squared per day and 2x10-4, respectively. The upper and lower Midville aquifers and the middle lower Midville confining unit, which is 85-feet thick in this area, yielded horizontal hydraulic conductivity and specific storage values of about 45 feet per day and 2x10-6 ft-1, respectively. Results from the 24-hour aquifer test also indicate a low horizontal hydraulic conductivity for the lower Dublin aquifer of less than 1 foot per day. Of the 35 volatile organic compounds (VOCs) analyzed in 23 groundwater samples during 2008–2009, only six were detected above laboratory reporting limits in samples from eight wells. No concentration in groundwater samples collected during 2008–2009 exceeded drinking water standards. Trichloroethene had the maximum VOC concentration (1.9 micrograms per liter) collected from a water sample during 2008–2009. Water-quality sampling of several wells near Well Field 2 indicate that, while in operation, the northernmost production well might have diverted groundwater, containing low levels of trichloroethene from at least two other production wells. Analysis of sulfur hexafluoride data indicate the average year of recharge ranges between 1981 and 1984 for water samples from five wells open to the upper and lower Midville aquifers, and 1991 for a water sample from one shallow well open to the lower Dublin aquifer. All of these ages suggest a short flow path and nearby source of contamination. The actual source of low levels of VOCs at Well Field 2 remains unknown. Three newly installed monitoring wells indicate that hydrogeologic units beneath Well Fields 2 and 3 are composed of sand and clay layers. Hydrogeologic units, encountered at Well Field 2, in order of increasing depth are the lower Dublin confining unit, lower Dublin aquifer, upper Midville confining unit, upper Midville aquifer, lower Midville confining unit, and lower Midville aquifer. West of Well Field 3, hydrogeologic units, in order of increasing depth are the Upper Three Runs aquifer, Gordon confining unit, Gordon aquifer, lower Dublin confining unit, lower Dublin aquifer, upper Midville confining unit, upper Midville aquifer, lower Midville confining unit, and lower Midville aquifer.

  10. WTAQ - A computer program for aquifer-test analysis of confined and unconfined aquifers

    USGS Publications Warehouse

    Barlow, P.M.; Moench, A.F.

    2004-01-01

    Computer program WTAQ was developed to implement a Laplace-transform analytical solution for axial-symmetric flow to a partially penetrating, finite-diameter well in a homogeneous and anisotropic unconfined (water-table) aquifer. The solution accounts for wellbore storage and skin effects at the pumped well, delayed response at an observation well, and delayed or instantaneous drainage from the unsaturated zone. For the particular case of zero drainage from the unsaturated zone, the solution simplifies to that of axial-symmetric flow in a confined aquifer. WTAQ calculates theoretical time-drawdown curves for the pumped well and observation wells and piezometers. The theoretical curves are used with measured time-drawdown data to estimate hydraulic parameters of confined or unconfined aquifers by graphical type-curve methods or by automatic parameter-estimation methods. Parameters that can be estimated are horizontal and vertical hydraulic conductivity, specific storage, and specific yield. A sample application illustrates use of WTAQ for estimating hydraulic parameters of a hypothetical, unconfined aquifer by type-curve methods. Copyright ASCE 2004.

  11. Summary of hydrologic testing of the Floridan aquifer system at Fort Stewart, Georgia

    USGS Publications Warehouse

    Gonthier, Gerard

    2011-01-01

    Flowmeter surveys at the study site indicate several permeable zones within the Floridan aquifer system. The Upper Floridan aquifer is composed of two water-bearing zones-the upper zone and the lower zone. The upper zone extends from 520 to 650 feet below land surface, contributes 96 percent of the total flow, and is more permeable than the lower zone, which extends from 650 to 705 feet below land surface and contributes the remaining 4 percent of the flow. The Lower Floridan aquifer consists of three zones at depths of 912-947, 1,090-1,139, and 1,211-1,250 feet below land surface that are inter-layered with three less-permeable zones. The Lower Floridan confining unit includes a permeable zone that extends from 793 to 822 feet below land surface. Horizontal hydraulic conductivity values of the Lower Floridan confining unit derived from slug tests within four packer-isolated intervals were from 2 to 20 feet per day, with a high value of 70 feet per day obtained for one of the intervals. Aquifer testing, using analytical techniques and model simulation, indicated the Upper Floridan aquifer had a transmissivity of about 100,000 feet squared per day, and the Lower Floridan aquifer had a transmissivity of 7,000 feet squared per day. Flowmeter surveys, slug tests within packer-isolated intervals, and parameter-estimation results indicate that the hydraulic properties of the Lower Floridan confining unit are similar to those of the Lower Floridan aquifer. Water-level data, for each aquifer test, were filtered for external influences such as barometric pressure, earth-tide effects, and long-term trends to enable detection of small water-level responses to aquifer-test pumping of less than 1 foot. During a 72-hour aquifer test of the Lower Floridan aquifer, a drawdown response of 0.3 to 0.4 foot was observed in two Upper Floridan aquifer wells, one of which was more than 1 mile away from the pumped well.

  12. Investigation of artificial recharge of aquifers in Nebraska

    USGS Publications Warehouse

    Lichtler, William F.; Stannard, David I.; Kouma, Edwin

    1980-01-01

    Progressive declines of ground-water levels in some areas of Nebraska prompted this investigation into the technical feasibility of recharging aquifers through wells, impoundments, pits, and canals. Information gained from a literature search and from preliminary tests was used to design several artificial-recharge experiments in Nebraska from 1977 to 1979. In well experiments, 0.46 billion gallons of water from an aquifer recharged by the Platte River was transported by pipeline and injected through a well into a sand and gravel aquifer near Aurora. Recharge was at about 730 gallons per minute during tests of 6- and 8-months duration. No evidence of clogging of the aquifer due to chemical reactions, air entrainment, or bacteria was detected in either test. In the 6-month test, evidence of clogging due to fine sediment in the recharge water was detected; however, analysis of this test indicated that recharge could have continued for several years before rehabilitation would have become necessary. Results of the 8-month test confirmed results of the earlier test until casing failure in the supply well and subsequent sediment deposition in the recharge well caused rapid water-level rise in the recharge well. In surface-spreading experiments, maximum infiltration rates from 24-foot-diameter ring infiltrometers near Aurora and Tryon were 0.4 and 11 feet per day, respectively. Results indicate that large-scale surface spreading is feasible only where low-permeability layers are absent in the subsurface. Infiltration rates from reuse pits ranged from 0.01 to 1.6 feet per day, indicating highly variable subsurface permeability. Flow measurements in an irrigation canal near Farwell indicate an infiltration rate of 0.37 feet per day. (USGS)

  13. Accounting for Aquifer Heterogeneity in Analysis of the Skin Effect

    NASA Astrophysics Data System (ADS)

    Barrash, W.; Clemo, T.; Fox, J. J.; Johnson, T. C.

    2005-12-01

    Because results of hydraulic tests in boreholes can be influenced by wellbore skin, understanding and quantification of wellbore skin improves our ability to estimate hydraulic conductivity (K) with such tests. We have investigated positive skin at 10-cm ID PVC wells with slotted casing that were emplaced in a 15-m thick coarse fluvial aquifer at the Boise Hydrogeophysical Research Site (BHRS), and we have concluded that the skin effect derives from sand grains partially clogging the slotted casing. We use the WTAQ code (Moench, 1997; Barlow and Moench, 1999) with a redefinition of the term for delayed observation well response to include skin effects at observation wells (in addition to pumping wells) in order to analyze aquifer tests for average skin conductivity (Ks) values at individual wells at the BHRS. Systematic differences in Ks values are recognized in results at pumping (Ks Q) and observation (Ks obs) wells: larger values are seen at observation wells (average Ks obs = 0.0023 cm/s) than pumping wells. Two possible causes are recognized for the occurrence of higher Ks values at observation wells than pumping wells: (1) flow diversion between aquifer layers on approach to a pumping well with a positive skin; and (2) larger portion of flow passing through lower-K zones in the heterogeneous aquifer near the pumping well than the observation wells due to strongly radially convergent flow near the pumping well. Because of the increased drawdown at a pumping well compared with an observation well due to heterogeneity in the aquifer, observation wells provide better Ks estimates than those from pumping wells for the well-aquifer system at the BHRS.

  14. Estimation of hectare-scale soil-moisture characteristics from aquifer-test data

    USGS Publications Warehouse

    Moench, A.F.

    2003-01-01

    Analysis of a 72-h, constant-rate aquifer test conducted in a coarse-grained and highly permeable, glacial outwash deposit on Cape Cod, Massachusetts revealed that drawdowns measured in 20 piezometers located at various depths below the water table and distances from the pumped well were significantly influenced by effects of drainage from the vadose zone. The influence was greatest in piezometers located close to the water table and diminished with increasing depth. The influence of the vadose zone was evident from a gap, in the intermediate-time zone, between measured drawdowns and drawdowns computed under the assumption that drainage from the vadose zone occurred instantaneously in response to a decline in the elevation of the water table. By means of an analytical model that was designed to account for time-varying drainage, simulated drawdowns could be closely fitted to measured drawdowns regardless of the piezometer locations. Because of the exceptional quality and quantity of the data and the relatively small aquifer heterogeneity, it was possible by inverse modeling to estimate all relevant aquifer parameters and a set of three empirical constants used in the upper-boundary condition to account for the dynamic drainage process. The empirical constants were used to define a one-dimensional (ID) drainage versus time curve that is assumed to be representative of the bulk material overlying the water table. The curve was inverted with a parameter estimation algorithm and a ID numerical model for variably saturated flow to obtain soil-moisture retention curves and unsaturated hydraulic conductivity relationships defined by the Brooks and Corey equations. Direct analysis of the aquifer-test data using a parameter estimation algorithm and a two-dimensional, axisymmetric numerical model for variably saturated flow yielded similar soil-moisture characteristics. Results suggest that hectare-scale soil-moisture characteristics are different from core-scale predictions and even relatively small amounts of fine-grained material and heterogeneity can dominate the large-scale soil-moisture characteristics and aquifer response. ?? 2003 Elsevier B.V. All rights reserved.

  15. Hydrogeology of glacial deposits in a preglacial bedrock valley, Waukesha County, Wisconsin

    USGS Publications Warehouse

    Batten, W.G.; Conlon, T.D.

    1993-01-01

    Results of a 6.5-hour aquifer test indicate that the silty sand and gravel deposits have an average transmissivity of about 140 feet squared per day and an average storage coefficient of about 1.2x10"3 at one location. The horizontal hydraulic conductivity of these deposits averages about 4 feet per day. Analysis of drawdown indicates that these deposits are part of a leaky confined-aquifer system and that some water is derived from storage in an overlying clay layer. The transmissivity value determined from this aquifer test and a lack of clean sand and gravel encountered in other test holes indicate that glacial deposits at these sites may not yield enough water for a large municipal water supply. Sand and gravel deposits, capable of development as a municipal supply, may be present in the southern part of the study area. However, additional test holes are needed to determine whether adequate sand and gravel deposits underlie this area.

  16. Using borehole flow logging to optimize hydraulic-test procedures in heterogeneous fractured aquifers

    USGS Publications Warehouse

    Paillet, F.L.

    1995-01-01

    Hydraulic properties of heterogeneous fractured aquifers are difficult to characterize, and such characterization usually requires equipment-intensive and time-consuming applications of hydraulic testing in situ. Conventional coring and geophysical logging techniques provide useful and reliable information on the distribution of bedding planes, fractures and solution openings along boreholes, but it is often unclear how these locally permeable features are organized into larger-scale zones of hydraulic conductivity. New boreholes flow-logging equipment provides techniques designed to identify hydraulically active fractures intersecting boreholes, and to indicate how these fractures might be connected to larger-scale flow paths in the surrounding aquifer. Potential complications in interpreting flowmeter logs include: 1) Ambient hydraulic conditions that mask the detection of hydraulically active fractures; 2) Inability to maintain quasi-steady drawdowns during aquifer tests, which causes temporal variations in flow intensity to be confused with inflows during pumping; and 3) Effects of uncontrolled background variations in hydraulic head, which also complicate the interpretation of inflows during aquifer tests. Application of these techniques is illustrated by the analysis of cross-borehole flowmeter data from an array of four bedrock boreholes in granitic schist at the Mirror Lake, New Hampshire, research site. Only two days of field operations were required to unambiguously identify the few fractures or fracture zones that contribute most inflow to boreholes in the CO borehole array during pumping. Such information was critical in the interpretation of water-quality data. This information also permitted the setting of the available string of two packers in each borehole so as to return the aquifer as close to pre-drilling conditions as possible with the available equipment.

  17. Regional Aquifer-System Analysis Program of the US Geological Survey; bibliography, 1978-86

    USGS Publications Warehouse

    Weeks, J.B.; Sun, Ren Jen

    1987-01-01

    The Regional Aquifer-System Analysis Program of the U.S. Geological Survey was initiated in 1978. The purpose of this program is to define the regional geohydrology and establish a framework of background information on geology, hydrology, and geochemistry of the Nation 's important aquifer systems. This information is needed to develop an understanding of the Nation 's major groundwater flow systems and to support better groundwater resources management. As of 1986, investigations of 28 regional aquifer systems were planned, investigations of 9 regional aquifer systems were completed, and 11 regional aquifer systems were being studied. This report is a bibliography of reports completed under the Regional Aquifer-System Analysis Program from 1978 through 1986. The reports resulting from each regional aquifer-system study are listed after an introduction to the study. During 1978-86, 488 reports were completed under the Regional Aquifer-System Analysis Program, and 168 reports which were partially funded by the Regional Aquifer-System Analysis Program were completed under the National Research Program. (Author 's abstract)

  18. Construction, Geology, and Aquifer Testing of the Maalo Road, Aahoaka Hill, and Upper Eleele Tank Monitor Wells, Kauai, Hawaii

    USGS Publications Warehouse

    Izuka, Scot K.

    2005-01-01

    The Maalo Road, Aahoaka Hill, and Upper Eleele Tank monitor wells were constructed using rotary drilling methods between July 1998 and August 2002 as part of a program of exploratory drilling, aquifer testing, and hydrologic analysis on Kauai. Aquifer tests were conducted in the uncased boreholes of the wells. The Maalo Road monitor well in the Lihue Basin penetrated 915 feet, mostly through mafic lava flows. Most of the rock samples from this well had chemical compositions similar to the Koloa Volcanics, but the deepest sample analyzed had a composition similar to the Waimea Canyon Basalt. Water temperature ranged from 25.6 to 27.4 degrees Celsius and specific conductance ranged from 303 to 627 microsiemens per centimeter during aquifer testing. Discharge rate ranged from 174 to 220 gallons per minute and maximum drawdown was 138.25 ft during a 7-day sustained-discharge test, but the test was affected by pump and generator problems. The Aahoaka Hill monitor well in the Lihue Basin penetrated 804 feet, mostly through mafic lava flows and possibly dikes. The well penetrated rocks having chemical compositions similar to the Waimea Canyon Basalt. During the first three hours of a sustained-discharge aquifer test in which the discharge rate varied between 92 and 117 gallons per minute, water temperature was 24.6 to 25.6 degrees Celsius, and specific conductance was 212 to 238 microsiemens per centimeter; this test was halted after a short period because drawdown was high. In a subsequent 7-day test, discharge was 8 to 23 gallons per minute, and maximum drawdown was 37.71 feet after 1,515 minutes of testing. The Upper Eleele Tank monitor well is near the Hanapepe River Valley. The well penetrated 740 feet through soil, sediment, mafic lava flows, volcanic ash, and scoria. Rocks above a depth of 345 feet had compositions similar to the Koloa Volcanics, but a sample from 720 to 725 feet had a composition similar to rocks of the Waimea Canyon Basalt. During a 7-day aquifer test with a sustained discharge between 278 and 290 gallons per minute, most of the drawdown of 1.10 feet occurred in the first 455 minutes of the test. Water levels measured thereafter may have been influenced by pumping from a nearby well. Water temperature ranged from 20.2 to 21.4 degrees Celsius and specific conductance from 8,380 to 18,940 microsiemens per centimeter during the aquifer tests.

  19. Recharge rates and aquifer hydraulic characteristics for selected drainage basins in middle and east Tennessee

    USGS Publications Warehouse

    Hoos, A.B.

    1990-01-01

    Quantitative information concerning aquifer hydrologic and hydraulic characteristics is needed to manage the development of ground-water resources. These characteristics are poorly defined for the bedrock aquifers in Middle and East Tennessee where demand for water is increasing. This report presents estimates of recharge rate, storage coefficient, diffusivity, and transmissivity for representative drainage basins in Middle and East Tennessee, as determined from analyses of stream-aquifer interactions. The drainage basins have been grouped according to the underlying major aquifer, then statistical descriptions applied to each group, in order to define area1 distribution of these characteristics. Aquifer recharge rates are estimated for representative low, average, and high flow years for 63 drainage basins using hydrograph analysis techniques. Net annual recharge during average flow years for all basins ranges from 4.1 to 16.8 in/yr (inches per year), with a mean value of 7.3 in. In general, recharge rates are highest for basins underlain by the Blue Ridge aquifer (mean value11.7 in/yr) and lowest for basins underlain by the Central Basin aquifer (mean value 5.6 in/yr). Mean recharge values for the Cumberland Plateau, Highland Rim, and Valley and Ridge aquifers are 6.5, 7.4, and 6.6 in/yr, respectively. Gravity drainage characterizes ground-water flow in most surficial bedrock aquifer in Tennessee. Accordingly, a gravity yield analysis, which compares concurrent water-level and streamflow hydrographs, was used to estimate aquifer storage coefficient for nine study basins. The basin estimates range from 0.002 to 0.140; however, most estimates are within a narrow range of values, from 0.01 to 0.025. Accordingly, storage coefficient is estimated to be 0.01 for all aquifers in Middle and East Tennessee, with the exception of the aquifer in the inner part of the Central Basin, for which storage coefficient is estimated to be 0.002. Estimates of aquifer hydraulic diffusivity are derived from estimates of the streamflow recession index and drainage density for 75 drainage basins; values range from 3,300 to 130,000 ft^2/d (feet squared per day). Basin-specific and site-specific estimates of transmissivity are computed from estimates of hydraulic diffusivity and specific-capacity test data, respectively. Basin-specific, or areal, estimates of transmissivity range from 22 to 1,300 ft^2/d, with a mean of 240 ft^2/d In general, areal transmissivity is highest for basins underlain by the Cumberland Plateau aquifer (mean value 480 ft^2/d) and lowest for basins underlain by the Central Basin aquifer (mean value 79 ft^2/d). Mean transmissivity values for the Highland Rim, Valley and Ridge, and Blue Ridge aquifer are 320,140, and 120 ft^2/d respectively. Site-specific estimates of transmissivity, computed from specific-capacity data from 118 test wells in Middle and East Tennessee range from 2 to 93,000 ft^2/d with a mean of 2,600 ft^2/d Mean transmissivity values for the Cumberland Plateau, Highland Rim, Central Basin, Valley and Ridge, and Blue Ridge aquifers are 2,800,1,200, 7,800, 390, and 65Oft Id, respectively.

  20. T-COMP—A suite of programs for extracting transmissivity from MODFLOW models

    USGS Publications Warehouse

    Halford, Keith J.

    2016-02-12

    Simulated transmissivities are constrained poorly by assigning permissible ranges of hydraulic conductivities from aquifer-test results to hydrogeologic units in groundwater-flow models. These wide ranges are derived from interpretations of many aquifer tests that are categorized by hydrogeologic unit. Uncertainty is added where contributing thicknesses differ between field estimates and numerical models. Wide ranges of hydraulic conductivities and discordant thicknesses result in simulated transmissivities that frequently are much greater than aquifer-test results. Multiple orders of magnitude differences frequently occur between simulated and observed transmissivities where observed transmissivities are less than 1,000 feet squared per day.Transmissivity observations from individual aquifer tests can constrain model calibration as head and flow observations do. This approach is superior to diluting aquifer-test results into generalized ranges of hydraulic conductivities. Observed and simulated transmissivities can be compared directly with T-COMP, a suite of three FORTRAN programs. Transmissivity observations require that simulated hydraulic conductivities and thicknesses in the volume investigated by an aquifer test be extracted and integrated into a simulated transmissivity. Transmissivities of MODFLOW model cells are sampled within the volume affected by an aquifer test as defined by a well-specific, radial-flow model of each aquifer test. Sampled transmissivities of model cells are averaged within a layer and summed across layers. Accuracy of the approach was tested with hypothetical, multiple-aquifer models where specified transmissivities ranged between 250 and 20,000 feet squared per day. More than 90 percent of simulated transmissivities were within a factor of 2 of specified transmissivities.

  1. Comparison of aquifer characterization approaches through steady state groundwater model validation: A controlled laboratory sandbox study

    USGS Publications Warehouse

    Illman, W.A.; Zhu, J.; Craig, A.J.; Yin, D.

    2010-01-01

    Groundwater modeling has become a vital component to water supply and contaminant transport investigations. An important component of groundwater modeling under steady state conditions is selecting a representative hydraulic conductivity (K) estimate or set of estimates which defines the K field of the studied region. Currently, there are a number of characterization approaches to obtain K at various scales and in varying degrees of detail, but there is a paucity of information in terms of which characterization approach best predicts flow through aquifers or drawdowns caused by some drawdown inducing events. The main objective of this paper is to assess K estimates obtained by various approaches by predicting drawdowns from independent cross-hole pumping tests and total flow rates through a synthetic heterogeneous aquifer from flow-through tests. Specifically, we (1) characterize a synthetic heterogeneous aquifer built in the sandbox through various techniques (permeameter analyses of core samples, single-hole, cross-hole, and flow-through testing), (2) obtain mean K fields through traditional analysis of test data by treating the medium to be homogeneous, (3) obtain heterogeneous K fields through kriging and steady state hydraulic tomography, and (4) conduct forward simulations of 16 independent pumping tests and six flowthrough tests using these homogeneous and heterogeneous K fields and comparing them to actual data. Results show that the mean K and heterogeneous K fields estimated through kriging of small-scale K data (core and single-hole tests) yield biased predictions of drawdowns and flow rates in this synthetic heterogeneous aquifer. In contrast, the heterogeneous K distribution or ?K tomogram? estimated via steady state hydraulic tomography yields excellent predictions of drawdowns of pumping tests not used in the construction of the tomogram and very good estimates of total flow rates from the flowthrough tests. These results suggest that steady state groundwater model validation is possible in this laboratory sandbox aquifer if the heterogeneous K distribution and forcing functions (boundary conditions and source/sink terms) are characterized sufficiently. ?? 2010 by the American Geophysical Union.

  2. Smoothing analysis of slug tests data for aquifer characterization at laboratory scale

    NASA Astrophysics Data System (ADS)

    Aristodemo, Francesco; Ianchello, Mario; Fallico, Carmine

    2018-07-01

    The present paper proposes a smoothing analysis of hydraulic head data sets obtained by means of different slug tests introduced in a confined aquifer. Laboratory experiments were performed through a 3D large-scale physical model built at the University of Calabria. The hydraulic head data were obtained by a pressure transducer placed in the injection well and subjected to a processing operation to smooth out the high-frequency noise occurring in the recorded signals. The adopted smoothing techniques working in time, frequency and time-frequency domain are the Savitzky-Golay filter modeled by third-order polynomial, the Fourier Transform and two types of Wavelet Transform (Mexican hat and Morlet). The performances of the filtered time series of the hydraulic heads for different slug volumes and measurement frequencies were statistically analyzed in terms of optimal fitting of the classical Cooper's equation. For practical purposes, the hydraulic heads smoothed by the involved techniques were used to determine the hydraulic conductivity of the aquifer. The energy contents and the frequency oscillations of the hydraulic head variations in the aquifer were exploited in the time-frequency domain by means of Wavelet Transform as well as the non-linear features of the observed hydraulic head oscillations around the theoretical Cooper's equation.

  3. A quantitative analysis of hydraulic interaction processes in stream-aquifer systems

    PubMed Central

    Wang, Wenke; Dai, Zhenxue; Zhao, Yaqian; Li, Junting; Duan, Lei; Wang, Zhoufeng; Zhu, Lin

    2016-01-01

    The hydraulic relationship between the stream and aquifer can be altered from hydraulic connection to disconnection when the pumping rate exceeds the maximum seepage flux of the streambed. This study proposes to quantitatively analyze the physical processes of stream-aquifer systems from connection to disconnection. A free water table equation is adopted to clarify under what conditions a stream starts to separate hydraulically from an aquifer. Both the theoretical analysis and laboratory tests have demonstrated that the hydraulic connectedness of the stream-aquifer system can reach a critical disconnection state when the horizontal hydraulic gradient at the free water surface is equal to zero and the vertical is equal to 1. A boundary-value problem for movement of the critical point of disconnection is established for an analytical solution of the inverted water table movement beneath the stream. The result indicates that the maximum distance or thickness of the inverted water table is equal to the water depth in the stream, and at a steady state of disconnection, the maximum hydraulic gradient at the streambed center is 2. This study helps us to understand the hydraulic phenomena of water flow near streams and accurately assess surface water and groundwater resources. PMID:26818442

  4. Flow-system analysis of the Madison and Minnelusa aquifers in the Rapid City area, South Dakota--conceptual model

    USGS Publications Warehouse

    Long, Andrew J.; Putnam, Larry D.

    2002-01-01

    The conceptual model of the Madison and Minnelusa aquifers in the Rapid City area synthesizes the physical geography, hydraulic properties, and ground-water flow components of these important aquifers. The Madison hydrogeologic unit includes the karstic Madison aquifer, which is defined as the upper, more permeable 100 to 200 ft of the Madison Limestone, and the Madison confining unit, which consists of the lower, less permeable part of the Madison Limestone and the Englewood Formation. Overlying the Madison hydrogeologic unit is the Minnelusa hydrogeologic unit, which includes the Minnelusa aquifer in the upper, more permeable 200 to 300 ft and the Minnelusa confining unit in the lower, less permeable part. The Madison and Minnelusa hydrogeologic units outcrop in the study area on the eastern flank of the Black Hills where recharge occurs from streamflow losses and areal recharge. The conceptual model describes streamflow recharge, areal recharge, ground-water flow, storage in aquifers and confining units, unsaturated areas, leakage between aquifers, discharge from artesian springs, and regional outflow. Effective transmissivities estimated for the Madison aquifer range from 500 to 20,000 ft2/d and for the Minnelusa aquifer from 500 to 10,000 ft2/d. Localized anisotropic transmissivity in the Madison aquifer has tensor ratios as high as 45:1. Vertical hydraulic conductivities for the Minnelusa confining unit determined from aquifer tests range from 1.3x10-3 to 3.0x10-1 ft/d. The confined storage coefficient of the Madison and Minnelusa hydrogeologic units was estimated as 3x10-4 ft/d. Specific yield was estimated as 0.09 for the Madison and Minnelusa aquifers and 0.03 for the Madison and Minnelusa confining units. Potentiometric surfaces for the Madison and Minnelusa aquifers have a general easterly gradient of about 70 ft/mi with local variations. Temporal change in hydraulic head in the Madison and Minnelusa aquifers ranged from about 5 to 95 ft in water years 1988-97. The unconfined areas were estimated at about 53 and 36 mi2 for the Madison and Minnelusa hydrogeologic units, respectively, in contrast to an aquifer analysis area of 629 mi2. Dye-tracer tests, stable isotopes, and hydrogeologic features were analyzed conjunctively to estimate generalized ground-water flowpaths in the Madison aquifer and their influences on the Minnelusa aquifer. The western Rapid City area between Boxelder Creek and Spring Creek was characterized as having undergone extensive tectonic activity, greater brecciation in the Minnelusa Formation, large transmissivities, generally upward hydraulic gradients from the Madison aquifer to the Minnelusa aquifer, many karst springs, and converging flowpaths. Water-budget analysis included: (1) a dry-period budget for declining water levels; October 1, 1987, to March 31, 1993; (2) a wet-period budget for rising water levels, April 1, 1993, to September 30, 1997; and (3) a full 10-year period budget for water years 1988-97. By simultaneously balancing these water budgets, initial estimates of recharge, discharge, change in storage, and hydraulic properties were refined. Inflow rates for the 10-year budget included streamflow recharge of about 45 ft3/s or 61 percent of the total budget and areal recharge of 22 ft3/s or 30 percent. Streamflow recharge to the Madison hydrogeologic unit was about 86 percent of the total streamflow recharge. Outflow for the 10-year budget included springflow of 31 ft3/s or 42 percent of the total budget, water use of about 10 ft3/s or 14 percent, and regional outflow of 22 ft3/s or 30 percent. Ground-water storage increased 9 ft3/s during the 10-year period, and net ground-water movement from the Madison to Minnelusa hydrogeologic unit was about 8 ft3/s.

  5. Estimating Aquifer Properties Using Sinusoidal Pumping Tests

    NASA Astrophysics Data System (ADS)

    Rasmussen, T. C.; Haborak, K. G.; Young, M. H.

    2001-12-01

    We develop the theoretical and applied framework for using sinusoidal pumping tests to estimate aquifer properties for confined, leaky, and partially penetrating conditions. The framework 1) derives analytical solutions for three boundary conditions suitable for many practical applications, 2) validates the analytical solutions against a finite element model, 3) establishes a protocol for conducting sinusoidal pumping tests, and 4) estimates aquifer hydraulic parameters based on the analytical solutions. The analytical solutions to sinusoidal stimuli in radial coordinates are derived for boundary value problems that are analogous to the Theis (1935) confined aquifer solution, the Hantush and Jacob (1955) leaky aquifer solution, and the Hantush (1964) partially penetrated confined aquifer solution. The analytical solutions compare favorably to a finite-element solution of a simulated flow domain, except in the region immediately adjacent to the pumping well where the implicit assumption of zero borehole radius is violated. The procedure is demonstrated in one unconfined and two confined aquifer units near the General Separations Area at the Savannah River Site, a federal nuclear facility located in South Carolina. Aquifer hydraulic parameters estimated using this framework provide independent confirmation of parameters obtained from conventional aquifer tests. The sinusoidal approach also resulted in the elimination of investigation-derived wastes.

  6. A Note on the Fractal Behavior of Hydraulic Conductivity and Effective Porosity for Experimental Values in a Confined Aquifer

    PubMed Central

    De Bartolo, Samuele; Fallico, Carmine; Veltri, Massimo

    2013-01-01

    Hydraulic conductivity and effective porosity values for the confined sandy loam aquifer of the Montalto Uffugo (Italy) test field were obtained by laboratory and field measurements; the first ones were carried out on undisturbed soil samples and the others by slug and aquifer tests. A direct simple-scaling analysis was performed for the whole range of measurement and a comparison among the different types of fractal models describing the scale behavior was made. Some indications about the largest pore size to utilize in the fractal models were given. The results obtained for a sandy loam soil show that it is possible to obtain global indications on the behavior of the hydraulic conductivity versus the porosity utilizing a simple scaling relation and a fractal model in coupled manner. PMID:24385876

  7. Water-level, recharge, discharge, specific-capacity, well-yield, and aquifer-test data for the Edwards aquifer in the San Antonio area, Texas

    USGS Publications Warehouse

    Maclay, R.W.; Small, T.A.; Rettman, P.L.

    1980-01-01

    This report presents data and informat ion, and indicates other sources of data, on water level s, recharge, discharge, spec ifi c capacity, well yields, and aquifer tests for the Edwards aquifer in the Sa n Antonio area, Texas.

  8. Predevelopment Water-Level Contours for Aquifers in the Rainier Mesa and Shoshone Mountain area of the Nevada Test Site, Nye County, Nevada

    USGS Publications Warehouse

    Fenelon, Joseph M.; Laczniak, Randell J.; Halford, Keith J.

    2008-01-01

    Contaminants introduced into the subsurface of the Nevada Test Site at Rainier Mesa and Shoshone Mountain by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. Although contaminants were introduced into low-permeability rocks above the regional flow system, the potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by ground-water transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the water-level distribution within each of the major aquifers underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. The contoured water-level distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped, presented, and discussed in general terms as being one of three aquifer types?volcanic aquifer, upper carbonate aquifer, or lower carbonate aquifer. Each of these aquifer types was subdivided and mapped as independent continuous and isolated aquifers, based on the continuity of its component rock. Ground-water flow directions, as related to the transport of test-generated contaminants, were developed from water-level contours and are presented and discussed for each of the continuous aquifers. Contoured water-level altitudes vary across the study area and range from more than 5,000 feet in the volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,450 feet in the lower carbonate aquifer in the southern part of the study area. Variations in water-level altitudes within any single continuous aquifer range from a few hundred feet in a lower carbonate aquifer to just more than 1,100 feet in a volcanic aquifer. Flow directions throughout the study area are dominantly southward with minor eastward or westward deviations. Primary exceptions are westward flow in the northern part of the volcanic aquifer and eastward flow in the eastern part of the lower carbonate aquifer. Northward flow in the upper and lower carbonate aquifers in the northern part of the study area is possible but cannot be substantiated because data are lacking. Interflow between continuous aquifers is evaluated and mapped to define major flow paths. These flow paths delineate tributary flow systems, which converge to form the regional ground-water flow system. The implications of these tributary flow paths in controlling transport away from the underground test areas at Rainier Mesa and Shoshone Mountain are discussed. The obvious data gaps contributing to uncertainties in the delineation of aquifers and development of water-level contours are identified and evaluated.

  9. Analysis of pumping tests of partially penetrating wells in an unconfined aquifer using inverse numerical optimization

    NASA Astrophysics Data System (ADS)

    Hvilshøj, S.; Jensen, K. H.; Barlebo, H. C.; Madsen, B.

    1999-08-01

    Inverse numerical modeling was applied to analyze pumping tests of partially penetrating wells carried out in three wells established in an unconfined aquifer in Vejen, Denmark, where extensive field investigations had previously been carried out, including tracer tests, mini-slug tests, and other hydraulic tests. Drawdown data from multiple piezometers located at various horizontal and vertical distances from the pumping well were included in the optimization. Horizontal and vertical hydraulic conductivities, specific storage, and specific yield were estimated, assuming that the aquifer was either a homogeneous system with vertical anisotropy or composed of two or three layers of different hydraulic properties. In two out of three cases, a more accurate interpretation was obtained for a multi-layer model defined on the basis of lithostratigraphic information obtained from geological descriptions of sediment samples, gammalogs, and flow-meter tests. Analysis of the pumping tests resulted in values for horizontal hydraulic conductivities that are in good accordance with those obtained from slug tests and mini-slug tests. Besides the horizontal hydraulic conductivity, it is possible to determine the vertical hydraulic conductivity, specific yield, and specific storage based on a pumping test of a partially penetrating well. The study demonstrates that pumping tests of partially penetrating wells can be analyzed using inverse numerical models. The model used in the study was a finite-element flow model combined with a non-linear regression model. Such a model can accommodate more geological information and complex boundary conditions, and the parameter-estimation procedure can be formalized to obtain optimum estimates of hydraulic parameters and their standard deviations.

  10. Hydrologic and Geochemical Evaluation of Aquifer Storage Recovery in the Santee Limestone/Black Mingo Aquifer, Charleston, South Carolina, 1998-2002

    USGS Publications Warehouse

    Petkewich, Matthew D.; Parkhurst, David L.; Conlon, Kevin J.; Campbell, Bruce G.; Mirecki, June E.

    2004-01-01

    The hydrologic and geochemical effects of aquifer storage recovery were evaluated to determine the potential for supplying the city of Charleston, South Carolina, with large quantities of potable water during emergencies, such as earthquakes, hurricanes, or hard freezes. An aquifer storage recovery system, including a production well and three observation wells, was installed at a site located on the Charleston peninsula. The focus of this study was the 23.2-meter thick Tertiary-age carbonate and sand aquifer of the Santee Limestone and the Black Mingo Group, the northernmost equivalent of the Floridan aquifer system. Four cycles of injection, storage, and recovery were conducted between October 1999 and February 2002. Each cycle consisted of injecting between 6.90 and 7.19 million liters of water for storage periods of 1, 3, or 6 months. The volume of recovered water that did not exceed the U.S. Environmental Protection Agency secondary standard for chloride (250 milligrams per liter) varied from 1.48 to 2.46 million liters, which is equivalent to 21 and 34 percent of the total volume injected for the individual tests. Aquifer storage recovery testing occurred within two productive zones of the brackish Santee Limestone/Black Mingo aquifer. The individual productive zones were determined to be approximately 2 to 4 meters thick, based on borehole geophysical logs, electromagnetic flow-meter testing, and specific-conductance profiles collected within the observation wells. A transmissivity and storage coefficient of 37 meters squared per day and 3 x 10-5, respectively, were determined for the Santee Limestone/Black Mingo aquifer. Water-quality and sediment samples collected during this investigation documented baseline aquifer and injected water quality, aquifer matrix composition, and changes in injected/aquifer water quality during injection, storage, and recovery. A total of 193 water-quality samples were collected and analyzed for physical properties, major and minor ions, and nutrients. The aquifer and treated surface water were sodiumchloride and calcium/sodium-bicarbonate water types, respectively. Forty-five samples were collected and analyzed for total trihalomethane. Total trihalomethane data collected during aquifer storage recovery cycle 4 indicated that this constituent would not restrict the use of recovered water for drinking-water purposes. Analysis of six sediment samples collected from a cored well located near the aquifer storage recovery site showed that quartz and calcite were the dominant minerals in the Santee Limestone/Black Mingo aquifer. Estimated cation exchange capacity ranged from 12 to 36 milliequivalents per 100 grams in the lower section of the aquifer. A reactive transport model was developed that included two 2-meter thick layers to describe each of the production zones. The four layers composing the production zones were assigned porosities ranging from 0.1 to 0.3 and hydraulic conductivities ranging from 1 to 8.4 meters per day. Specific storage of the aquifer and confining units was estimated to be 1.5 x 10-5 meter-1. Longitudinal dispersivity of all layers was specified to be 0.5 meter. Leakage through the confining unit was estimated to be minimal and, therefore, not used in the reactive transport modeling. Inverse geochemical modeling indicates that mixing, cation exchange, and calcite dissolution are the dominant reactions that occur during aquifer storage recovery testing in the Santee Limestone/Black Mingo aquifer. Potable water injected into the Santee Limestone/Black Mingo aquifer evolved chemically by mixing with brackish background water and reaction with calcite and cation exchangers in the sediment. Reactive-transport model simulations indicated that the calcite and exchange reactions could be treated as equilibrium processes. Simulations with the calibrated reactive transport model indicated that approximately one-fourth of the total volume of water injected into

  11. Regional assessment of NLEAP NO3-N leaching indices

    USGS Publications Warehouse

    Wylie, B.K.; Shaffer, M.J.; Hall, M.D.

    1995-01-01

    Nonpoint source ground water contamination by nitrate nitrogen (NO3-N) leached from agricultural lands can be substantial and increase health risks to humans and animals. Accurate and rapid methods are needed to identify and map localities that have a high potential for contamination of shallow aquifers with NO3-N leached from agriculture. Evaluation of Nitrate Leaching and Economic Analysis Package (NLEAP) indices and input variables across an irrigated agricultural area on an alluvial aquifer in Colorado indicated that all leaching indices tested were more strongly correlated with aquifer NO3-N concentration than with aquifer N mass. Of the indices and variables tested, the NO3-N Leached (NL) index was the NLEAP index most strongly associated with groundwater NO3-N concentration (r2 values from 0.37 to 0.39). NO3-N concentration of the leachate was less well correlated with ground water NO3-N concentration (r2values from 0.21 to 0.22). Stepwise regression analysis indicated that, although inorganic and organic/inorganic fertilizer scenarios had similar r2 values, the Feedlot Indicator (proximity) variable was significant over and above the NO3-N Leached index for the inorganic scenario. The analysis also showed that combination of either Movement Risk Index (MIRI) or NO3-N concentration of the leachate with the NO3-N Leached index leads to an improved regression, which provides insight into area-wide associations between agricultural activities and ground water NO3-N concentration.

  12. Hydrostratigraphic interpretation of test-hole and borehole geophysical data, Kimball, Cheyenne, and Deuel Counties, Nebraska, 2011-12

    USGS Publications Warehouse

    Hobza, Christopher M.; Sibray, Steven S.

    2014-01-01

    Recently (2004) adopted legislation in Nebraska requires a sustainable balance between long-term supplies and uses of surface-water and groundwater and requires Natural Resources Districts to understand the effect of groundwater use on surface-water systems when developing a groundwater-management plan. The South Platte Natural Resources District (SPNRD) is located in the southern Nebraska Panhandle and overlies the nationally important High Plains aquifer. Declines in water levels have been documented, and more stringent regulations have been enacted to ensure the supply of ground-water will be sufficient to meet the needs of future generations. Because an improved understanding of the hydrogeologic characteristics of this aquifer system is needed to ensure sustainability of groundwater withdrawals, the U.S. Geological Survey, in cooperation with the SPNRD, Conservation and Survey Division of the University of Nebraska-Lincoln, and the Nebraska Environmental Trust, began a hydrogeologic study of the SPNRD to describe the lithology and thickness of the High Plains aquifer. This report documents these characteristics at 29 new test holes, 28 of which were drilled to the base of the High Plains aquifer. Herein the High Plains aquifer is considered to include all hydrologically connected units of Tertiary and Quaternary age. The depth to the base of aquifer was interpreted to range from 37 to 610 feet in 28 of the 29 test holes. At some locations, particularly northern Kimball County, the base-of-aquifer surface was difficult to interpret from drill cutting samples and borehole geophysical logs. The depth to the base of aquifer determined for test holes drilled for this report was compared with the base-of-aquifer surface interpreted by previous researchers. In general, there were greater differences between the base-of-aquifer elevation reported herein and those in previous studies for areas north of Lodgepole Creek compared to areas south of Lodgepole Creek. The largest difference was at test hole 5-SP-11, where an Ogallala-filled paleovalley prevously had been interpreted based on relatively sparse test-hole data west of 5-SP-11. The base of aquifer near test hole 5-SP-11 reported herein is approximately 230 ft higher in elevation than previously interpreted. Among other test holes that are likely to have been drilled in Ogallala-filled paleovalleys, the greatest difference in the interpreted base of aquifer was for test hole 7-CC-11, northeast of Potter, Nebraska, where the base of aquifer is 180 feet deeper than previously interpreted. Interpretation of test-hole and borehole geophysical data for 29 additional test holes will improve resource managers’ understanding of the hydrogeologic characteristics, including aquifer thickness. Aquifer thickness, which is related to total water in storage, is not well quantified in the north and south tablelands. The additional hydrostratigraphic interpretations provided in this report will improve the hydrogeologic framework used in current (2014) and future groundwater models, which are the basis for many water-management decisions.

  13. Predevelopment Water-Level Contours for Aquifers in the Rainier Mesa and Shoshone Mountain area of the Nevada Test Site, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joseph M. Fenelon; Randell J. Laczniak; and Keith J. Halford

    2008-06-24

    Contaminants introduced into the subsurface of the Nevada Test Site at Rainier Mesa and Shoshone Mountain by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. Although contaminants were introduced into low-permeability rocks above the regional flow system, the potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by ground-water transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the water-level distribution within each of the major aquifersmore » underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. The contoured water-level distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped, presented, and discussed in general terms as being one of three aquifer types—volcanic aquifer, upper carbonate aquifer, or lower carbonate aquifer. Each of these aquifer types was subdivided and mapped as independent continuous and isolated aquifers, based on the continuity of its component rock. Ground-water flow directions, as related to the transport of test-generated contaminants, were developed from water-level contours and are presented and discussed for each of the continuous aquifers. Contoured water-level altitudes vary across the study area and range from more than 5,000 feet in the volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,450 feet in the lower carbonate aquifer in the southern part of the study area. Variations in water-level altitudes within any single continuous aquifer range from a few hundred feet in a lower carbonate aquifer to just more than 1,100 feet in a volcanic aquifer. Flow directions throughout the study area are dominantly southward with minor eastward or westward deviations. Primary exceptions are westward flow in the northern part of the volcanic aquifer and eastward flow in the eastern part of the lower carbonate aquifer. Northward flow in the upper and lower carbonate aquifers in the northern part of the study area is possible but cannot be substantiated because data are lacking. Interflow between continuous aquifers is evaluated and mapped to define major flow paths. These flow paths delineate tributary flow systems, which converge to form the regional ground-water flow system. The implications of these tributary flow paths in controlling transport away from the underground test areas at Rainier Mesa and Shoshone Mountain are discussed. The obvious data gaps contributing to uncertainties in the delineation of aquifers and development of water-level contours are identified and evaluated.« less

  14. Estimating groundwater recharge uncertainty from joint application of an aquifer test and the water-table fluctuation method

    NASA Astrophysics Data System (ADS)

    Delottier, H.; Pryet, A.; Lemieux, J. M.; Dupuy, A.

    2018-05-01

    Specific yield and groundwater recharge of unconfined aquifers are both essential parameters for groundwater modeling and sustainable groundwater development, yet the collection of reliable estimates of these parameters remains challenging. Here, a joint approach combining an aquifer test with application of the water-table fluctuation (WTF) method is presented to estimate these parameters and quantify their uncertainty. The approach requires two wells: an observation well instrumented with a pressure probe for long-term monitoring and a pumping well, located in the vicinity, for the aquifer test. The derivative of observed drawdown levels highlights the necessity to represent delayed drainage from the unsaturated zone when interpreting the aquifer test results. Groundwater recharge is estimated with an event-based WTF method in order to minimize the transient effects of flow dynamics in the unsaturated zone. The uncertainty on groundwater recharge is obtained by the propagation of the uncertainties on specific yield (Bayesian inference) and groundwater recession dynamics (regression analysis) through the WTF equation. A major portion of the uncertainty on groundwater recharge originates from the uncertainty on the specific yield. The approach was applied to a site in Bordeaux (France). Groundwater recharge was estimated to be 335 mm with an associated uncertainty of 86.6 mm at 2σ. By the use of cost-effective instrumentation and parsimonious methods of interpretation, the replication of such a joint approach should be encouraged to provide reliable estimates of specific yield and groundwater recharge over a region of interest. This is necessary to reduce the predictive uncertainty of groundwater management models.

  15. Suggested Operating Procedures for Aquifer Pumping Tests

    EPA Pesticide Factsheets

    This document is intended as a primer, describing the process for the design and performance of an “aquifer test” (how to obtain reliable data from a pumping test) to obtain accurate estimates of aquifer parameters.

  16. Modeling cross-hole slug tests in an unconfined aquifer

    DOE PAGES

    Malama, Bwalya; Kuhlman, Kristopher L.; Brauchler, Ralf; ...

    2016-06-28

    Cross-hole slug test date are analyzed with an extended version of a recently published unconfined aquifer model accounting for waterable effects using the linearized kinematic condition. The use of cross-hole slug test data to characterize aquifer heterogeneity and source/observation well oscillation parameters is evaluated. The data were collected in a series of multi-well and multi-level pneumatic slug tests conducted at a site in Widen, Switzerland. Furthermore, the tests involved source and observation well pairs separated by distances of up to 4 m, and instrumented with pressure transducers to monitor aquifer response in discrete intervals.

  17. Quantification of aquifer properties with surface nuclear magnetic resonance in the Platte River valley, central Nebraska, using a novel inversion method

    USGS Publications Warehouse

    Irons, Trevor P.; Hobza, Christopher M.; Steele, Gregory V.; Abraham, Jared D.; Cannia, James C.; Woodward, Duane D.

    2012-01-01

    Surface nuclear magnetic resonance, a noninvasive geophysical method, measures a signal directly related to the amount of water in the subsurface. This allows for low-cost quantitative estimates of hydraulic parameters. In practice, however, additional factors influence the signal, complicating interpretation. The U.S. Geological Survey, in cooperation with the Central Platte Natural Resources District, evaluated whether hydraulic parameters derived from surface nuclear magnetic resonance data could provide valuable input into groundwater models used for evaluating water-management practices. Two calibration sites in Dawson County, Nebraska, were chosen based on previous detailed hydrogeologic and geophysical investigations. At both sites, surface nuclear magnetic resonance data were collected, and derived parameters were compared with results from four constant-discharge aquifer tests previously conducted at those same sites. Additionally, borehole electromagnetic-induction flowmeter data were analyzed as a less-expensive surrogate for traditional aquifer tests. Building on recent work, a novel surface nuclear magnetic resonance modeling and inversion method was developed that incorporates electrical conductivity and effects due to magnetic-field inhomogeneities, both of which can have a substantial impact on the data. After comparing surface nuclear magnetic resonance inversions at the two calibration sites, the nuclear magnetic-resonance-derived parameters were compared with previously performed aquifer tests in the Central Platte Natural Resources District. This comparison served as a blind test for the developed method. The nuclear magnetic-resonance-derived aquifer parameters were in agreement with results of aquifer tests where the environmental noise allowed data collection and the aquifer test zones overlapped with the surface nuclear magnetic resonance testing. In some cases, the previously performed aquifer tests were not designed fully to characterize the aquifer, and the surface nuclear magnetic resonance was able to provide missing data. In favorable locations, surface nuclear magnetic resonance is able to provide valuable noninvasive information about aquifer parameters and should be a useful tool for groundwater managers in Nebraska.

  18. Lithology, hydraulic properties, and water quality of the Sandstone Aquifer in the northwestern part of the Bad River Indian Reservation, Wisconsin, 1998-1999

    USGS Publications Warehouse

    Dunning, Charles P.

    2005-01-01

    The Precambrian sandstone aquifer in the northwestern part of the Bad River Band of Lake Superior Tribe of Chippewa Indians Reservation, Ashland County, Wisconsin, provides much of the drinking water to area residents. A study was undertaken in cooperation with the Bad River Tribe to provide specific information about the lithology, hydraulic properties, and water quality of the sandstone aquifer. During 1998 and 1999, the U.S. Geological Survey installed three monitoring wells, collected and analyzed lithologic and water samples, and conducted geophysical logging and aquifer tests to characterize the sandstone aquifer. The two monitoring wells in the southeastern part of the study area, the Diaperville Monitoring Well #1 (Diaperville MW #1) and the Tolman Monitoring Well #1 (Tolman MW #1) , are believed to have encountered older Middle Proterozoic Oronto Group sandstones. The sandstone encountered in the Ackley Monitoring Well #1 (Ackley MW #1) is believed to be Chequamegon Sandstone of the Late Proterozoic Bayfield Group. This interpretation is based on previous studies, as well as thin- section analysis of sandstone core recovered from the Ackley Monitoring Well #1. Results of aquifer tests conducted in the Diaperville Monitoring Well #1 and the Tolman Monitoring Well #1 provide ranges for hydraulic param - eter values in the sandstone aquifer: transmissivity ranges from 83 to 509 square feet per day; hydraulic conductivity ranges from 1.6 to 4.5 feet per day; storativity ranges from 0.00019 to 0.00046; and specific capacity ranges from 0.22 to 0.67 gallons per minute per foot. Though high- and low-angle fractures are present in Ackley Monitoring Well #1 core, the hydraulic properties of the bedrock appear to be due largely to the matrix porosity measured in thin section (16–21 percent) and permeability of the sandstone. The aquifer test for the Diaperville Monitoring Well #1 resulted in observed drawdown in nearby glacial wells, evidence of a hydraulic connection between the sandstone aquifer and the glacial deposits. Major ion analyses indicate that the water sampled from the sandstone aquifer at the Ackley site is of the calcium-magnesium-sodium- bicarbonate type. Based on a single sampling set, volatile organic constituents were not detected in water samples from the Diaperville Monitoring Well #1 or the Ackley Monitoring Well #1. 

  19. Groundwater Flow Systems at the Nevada Test Site, Nevada: A Synthesis of Potentiometric Contours, Hydrostratigraphy, and Geologic Structures

    USGS Publications Warehouse

    Fenelon, Joseph M.; Sweetkind, Donald S.; Laczniak, Randell J.

    2010-01-01

    Contaminants introduced into the subsurface of the Nevada Test Site by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. The potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by groundwater transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the hydraulic-head distribution within each of the major aquifers underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. A map of the hydraulic-head distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped and discussed in general terms as being one of two types: alluvial-volcanic, or carbonate. Both aquifer types are subdivided and mapped as independent regional and local aquifers, based on the continuity of their component rock. Groundwater-flow directions, approximated from potentiometric contours that were developed from the hydraulic-head distribution, are indicated on the maps and discussed for each of the regional aquifers and for selected local aquifers. Hydraulic heads vary across the study area and are interpreted to range in altitude from greater than 5,000 feet in a regional alluvial-volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,300 feet in regional alluvial-volcanic and carbonate aquifers in the southwestern part of the study area. Flow directions throughout the study area are dominantly south-southwest with some local deviations. Vertical hydraulic gradients between aquifer types are downward throughout most of the study area; however, flow from the alluvial-volcanic aquifer into the underlying carbonate aquifer, where both aquifers are present, is believed to be minor because of an intervening confining unit. Limited exchange of water between aquifer types occurs by diffuse flow through the confining unit, by focused flow along fault planes, or by direct flow where the confining unit is locally absent. Interflow between regional aquifers is evaluated and mapped to define major flow paths. These flow paths delineate tributary flow systems, which converge to form intermediate and regional flow systems. The implications of these flow systems in controlling transport of radionuclides away from the underground test areas at the Nevada Test Site are briefly discussed. Additionally, uncertainties in the delineation of aquifers, the development of potentiometric contours, and the identification of flow systems are identified and evaluated. Eleven tributary flow systems and three larger flow systems are mapped in the Nevada Test Site area. Flow systems within the alluvial-volcanic aquifer dominate the western half of the study area, whereas flow systems within the carbonate aquifer are most prevalent in the southeastern half of the study area. Most of the flow in the regional alluvial-volcanic aquifer that moves through the underground testing area on Pahute Mesa is discharged to the land surface at springs and seeps in Oasis Valley. Flow in the regional carbonate aquifer is internally compartmentalized by major geologic structures, primarily thrust faults, which constrain flow into separate corridors. Contaminants that reach the regional carbonate aquifer from testing areas in Yucca and Frenchman Flats flow toward downgradient discharge areas through the Alkali Flat-Furnace Creek Ranch or Ash Meadows flow systems and their tributaries.

  20. Cyclic injection, storage, and withdrawal of heated water in a sandstone aquifer at St. Paul, Minnesota--Analysis of thermal data and nonisothermal modeling of short-term test cycles

    USGS Publications Warehouse

    Miller, Robert T.; Delin, G.N.

    2002-01-01

    In May 1980, the University of Minnesota began a project to evaluate the feasibility of storing heated water (150 degrees Celsius) in the Franconia-Ironton Galesville aquifer (183 to 245 meters below land surface) and later recovering it for space heating. The University's steam-generation facilities supplied high-temperature water for injection. The Aquifer Thermal-Energy Storage system is a doublet-well design in which the injection-withdrawal wells are spaced approximately 250 meters apart. Water was pumped from one of the wells through a heat exchanger, where heat was added or removed. This water was then injected back into the aquifer through the other well. Four short-term test cycles were completed. Each cycle consisted of approximately equal durations of injection and withdrawal ranging from 5.25 to 8.01 days. Equal rates of injection and withdrawal, ranging from 17.4 to 18.6 liters per second, were maintained for each short-term test cycle. Average injection temperatures ranged from 88.5 to 117.9 degrees Celsius. Temperature graphs for selected depths at individual observation wells indicate that the Ironton and Galesville Sandstones received and stored more thermal energy than the upper part of the Franconia Formation. Clogging of the Ironton Sandstone was possibly due to precipitation of calcium carbonate or movement of fine-grain material or both. Vertical-profile plots indicate that the effects of buoyancy flow were small within the aquifer. A three-dimensional, anisotropic, nonisothermal, ground-water-flow, and thermal-energy-transport model was constructed to simulate the four short-term test cycles. The model was used to simulate the entire short-term testing period of approximately 400 days. The only model properties varied during model calibration were longitudinal and transverse thermal dispersivities, which, for final calibration, were simulated as 3.3 and 0.33 meters, respectively. The model was calibrated by comparing model-computed results to (1) measured temperatures at selected altitudes in four observation wells, (2) measured temperatures at the production well, and (3) calculated thermal efficiencies of the aquifer. Model-computed withdrawal-water temperatures were within an average of about 3 percent of measured values and model-computed aquifer-thermal efficiencies were within an average of about 5 percent of calculated values for the short-term test cycles. These data indicate that the model accurately simulated thermal-energy storage within the Franconia-Ironton-Galesville aquifer.

  1. Ground-Water Availability from the Hawi Aquifer in the Kohala Area, Hawaii

    USGS Publications Warehouse

    Underwood, Mark R.; Meyer, William; Souza, William R.

    1995-01-01

    A ground-water study consisting of test-well drilling, aquifer tests, and numerical simulation was done to investigate ground-water availability in the basal part of the Hawi aquifer between the western drainage divide of Pololu Valley and Upolu Point in Kohala, Hawaii. The test-well drilling provided information on geology, water levels, water quality, vertical extent of the freshwater, and the thickness of the freshwater-saltwater transition zone in that aquifer. A total of 12 test wells were drilled at eight locations. Aquifer tests were done at five locations to estimate the hydraulic conductivity of the aquifer. Using information on the distribution of recharge, vertical extent of freshwater, hydraulic conductivity, and geometry of the basal aquifer, a numerical model was used to simulate the movement of water into, through, and out of the basal aquifer, and the effect of additional pumping on the water levels in the aquifer. Results of the modeling indicate that ground-water withdrawal of 20 million gallons per day above the existing withdrawal of 0.6 million gallons per day from the basal aquifer is hydrologically feasible, but that spacing, depth, and pumping rates of individual wells are important. If pumping is concentrated, the likelihood of saltwater intrusion is increased. The additional withdrawal of 20 million gallons per day would result in a reduction of ground-water discharge to the ocean by an amount equal to pumpage. Although model-calculated declines in water-level outside the area of pumping are small, pumping could cause some reduction of streamflow near the mouth of Pololu Stream.

  2. Ground water hydraulics as a geophysical aid

    USGS Publications Warehouse

    Ferris, John G.

    1948-01-01

    The publication of the non-equilibrium formula in 1935 in a paper by Theis marked the opening of a new era in the analysis and understanding of the hydraulics of percolating ground waters. Through the past decade 9 an ever-increasing number of engineers and geologists have become familiar-with the application of this formula to practical problems of ground-water flow and have tested it in the field, against precise observations, under controlled conditions. Although the highly idealized aquifer assumed for the derivation of this formula is not of widespread occurrence in the field, we gain increasing confidence in the use of the Theis method as our backlog of proven data accumulates until we now look askance at test data which do not conform to this theory. In many cases, careful study of these anomalous data will reveal the means for estimating the degree or manner in which an observed aquifer diverges from the idealized aquifer.

  3. The in-situ decontamination of sand and gravel aquifers by chemically enhanced solubilization of multiple-compound DNAPLs with surfactant solutions: Phase 1 -- Laboratory and pilot field-scale testing and Phase 2 -- Solubilization test and partitioning and interwell tracer tests. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-10-24

    Laboratory, numerical simulation, and field studies have been conducted to assess the potential use of micellar-surfactant solutions to solubilize chlorinated solvents contaminating sand and gravel aquifers. Ninety-nine surfactants were screened for their ability to solubilize trichloroethene (TCE), perchloroethylene (PCE), and carbon tetrachloride (CTET). The field test was conducted in the alluvial aquifer which is located 20 to 30 meters beneath a vapor degreasing operation at Paducah Gaseous Diffusion Plant. This aquifer has become contaminated with TCE due to leakage of perhaps 40,000 liters of TCE, which has generated a plume of dissolved TCE extending throughout an area of approximately 3more » km{sup 2} in the aquifer. Most of the TCE is believed to be present in the overlying lacustrine deposits and in the aquifer itself as a dense, non-aqueous phase liquid, or DNAPL. The objective of the field test was to assess the efficacy of the surfactant for in situ TCE solubilization. Although the test demonstrated that sorbitan monooleate was unsuitable as a solubilizer in this aquifer, the single-well test was demonstrated to be a viable method for the in situ testing of surfactants or cosolvents prior to proceeding to full-scale remediation.« less

  4. Three-dimensional imaging of aquifer and aquitard heterogeneity via transient hydraulic tomography at a highly heterogeneous field site

    NASA Astrophysics Data System (ADS)

    Zhao, Zhanfeng; Illman, Walter A.

    2018-04-01

    Previous studies have shown that geostatistics-based transient hydraulic tomography (THT) is robust for subsurface heterogeneity characterization through the joint inverse modeling of multiple pumping tests. However, the hydraulic conductivity (K) and specific storage (Ss) estimates can be smooth or even erroneous for areas where pumping/observation densities are low. This renders the imaging of interlayer and intralayer heterogeneity of highly contrasting materials including their unit boundaries difficult. In this study, we further test the performance of THT by utilizing existing and newly collected pumping test data of longer durations that showed drawdown responses in both aquifer and aquitard units at a field site underlain by a highly heterogeneous glaciofluvial deposit. The robust performance of the THT is highlighted through the comparison of different degrees of model parameterization including: (1) the effective parameter approach; (2) the geological zonation approach relying on borehole logs; and (3) the geostatistical inversion approach considering different prior information (with/without geological data). Results reveal that the simultaneous analysis of eight pumping tests with the geostatistical inverse model yields the best results in terms of model calibration and validation. We also find that the joint interpretation of long-term drawdown data from aquifer and aquitard units is necessary in mapping their full heterogeneous patterns including intralayer variabilities. Moreover, as geological data are included as prior information in the geostatistics-based THT analysis, the estimated K values increasingly reflect the vertical distribution patterns of permeameter-estimated K in both aquifer and aquitard units. Finally, the comparison of various THT approaches reveals that differences in the estimated K and Ss tomograms result in significantly different transient drawdown predictions at observation ports.

  5. Reliable yields of public water-supply wells in the fractured-rock aquifers of central Maryland, USA

    NASA Astrophysics Data System (ADS)

    Hammond, Patrick A.

    2018-02-01

    Most studies of fractured-rock aquifers are about analytical models used for evaluating aquifer tests or numerical methods for describing groundwater flow, but there have been few investigations on how to estimate the reliable long-term drought yields of individual hard-rock wells. During the drought period of 1998 to 2002, many municipal water suppliers in the Piedmont/Blue Ridge areas of central Maryland (USA) had to institute water restrictions due to declining well yields. Previous estimates of the yields of those wells were commonly based on extrapolating drawdowns, measured during short-term single-well hydraulic pumping tests, to the first primary water-bearing fracture in a well. The extrapolations were often made from pseudo-equilibrium phases, frequently resulting in substantially over-estimated well yields. The methods developed in the present study to predict yields consist of extrapolating drawdown data from infinite acting radial flow periods or by fitting type curves of other conceptual models to the data, using diagnostic plots, inverse analysis and derivative analysis. Available drawdowns were determined by the positions of transition zones in crystalline rocks or thin-bedded consolidated sandstone/limestone layers (reservoir rocks). Aquifer dewatering effects were detected by type-curve matching of step-test data or by breaks in the drawdown curves constructed from hydraulic tests. Operational data were then used to confirm the predicted yields and compared to regional groundwater levels to determine seasonal variations in well yields. Such well yield estimates are needed by hydrogeologists and water engineers for the engineering design of water systems, but should be verified by the collection of long-term monitoring data.

  6. Advances toward field application of 3D hydraulic tomography

    NASA Astrophysics Data System (ADS)

    Cardiff, M. A.; Barrash, W.; Kitanidis, P. K.

    2011-12-01

    Hydraulic tomography (HT) is a technique that shows great potential for aquifer characterization and one that holds the promise of producing 3D hydraulic property distributions, given suitable equipment. First suggested over 15 years ago, HT assimilates distributed aquifer pressure (head) response data collected during a series of multiple pumping tests to produce estimates of aquifer property variability. Unlike traditional curve-matching analyses, which assume homogeneity or "effective" parameters within the radius of influence of a hydrologic test, HT analysis relies on numerical models with detailed heterogeneity in order to invert for the highly resolved 3D parameter distribution that jointly fits all data. Several numerical and laboratory investigations of characterization using HT have shown that property distributions can be accurately estimated between observation locations when experiments are correctly designed - a property not always shared by other, simpler 1D characterization approaches such as partially-penetrating slug tests. HT may represent one of the best methods available for obtaining detailed 3D aquifer property descriptions, especially in deep or "hard" aquifer materials, where direct-push methods may not be feasible. However, to date HT has not yet been widely adopted at contaminated field sites. We believe that current perceived impediments to HT adoption center around four key issues: 1) A paucity in the scientific literature of proven, cross-validated 3D field applications 2) A lack of guidelines and best practices for performing field 3D HT experiments; 3) Practical difficulty and time commitment associated with the installation of a large number of high-accuracy sampling locations, and the running of a large number of pumping tests; and 4) Computational difficulty associated with solving large-scale inverse problems for parameter identification. In this talk, we present current results in 3D HT research that addresses these four issues, and thus bring HT closer to field practice. Topics to be discussed include: -Improving field efficiency through design and implementation of new modular, easily-installed equipment for 3D HT. -Validating field-scale 3D HT through application and cross-validation at the Boise Hydrogeophysical Research Site. -Developing guidelines for HT implementation based on field experience, numerical modeling, and a comprehensive literature review of the past 15 years of HT research. -Application of novel, fast numerical methods for large-scale HT data analysis. The results presented will focus on the application of 3D HT, but in general we also hope to provide insights on aquifer characterization that stimulate thought on the issue of continually updating aquifer characteristics estimates while recognizing uncertainties and providing guidance for future data collection.

  7. The influence of geologic structures on deformation due to ground water withdrawal.

    PubMed

    Burbey, Thomas J

    2008-01-01

    A 62 day controlled aquifer test was conducted in thick alluvial deposits at Mesquite, Nevada, for the purpose of monitoring horizontal and vertical surface deformations using a high-precision global positioning system (GPS) network. Initial analysis of the data indicated an anisotropic aquifer system on the basis of the observed radial and tangential deformations. However, new InSAR data seem to indicate that the site may be bounded by an oblique normal fault as the subsidence bowl is both truncated to the northwest and offset from the pumping well to the south. A finite-element numerical model was developed using ABAQUS to evaluate the potential location and hydromechanical properties of the fault based on the observed horizontal deformations. Simulation results indicate that for the magnitude and direction of motion at the pumping well and at other GPS stations, which is toward the southeast (away from the inferred fault), the fault zone (5 m wide) must possess a very high permeability and storage coefficient and cross the study area in a northeast-southwest direction. Simulated horizontal and vertical displacements that include the fault zone closely match observed displacements and indicate the likelihood of the presence of the inferred fault. This analysis shows how monitoring horizontal displacements can provide valuable information about faults, and boundary conditions in general, in evaluating aquifer systems during an aquifer test.

  8. The Flow Dimension and Aquifer Heterogeneity: Field evidence and Numerical Analyses

    NASA Astrophysics Data System (ADS)

    Walker, D. D.; Cello, P. A.; Valocchi, A. J.; Roberts, R. M.; Loftis, B.

    2008-12-01

    The Generalized Radial Flow approach to hydraulic test interpretation infers the flow dimension to describe the geometry of the flow field during a hydraulic test. Noninteger values of the flow dimension often are inferred for tests in highly heterogeneous aquifers, yet subsequent modeling studies typically ignore the flow dimension. Monte Carlo analyses of detailed numerical models of aquifer tests examine the flow dimension for several stochastic models of heterogeneous transmissivity, T(x). These include multivariate lognormal, fractional Brownian motion, a site percolation network, and discrete linear features with lengths distributed as power-law. The behavior of the simulated flow dimensions are compared to the flow dimensions observed for multiple aquifer tests in a fractured dolomite aquifer in the Great Lakes region of North America. The combination of multiple hydraulic tests, observed fracture patterns, and the Monte Carlo results are used to screen models of heterogeneity and their parameters for subsequent groundwater flow modeling. The comparison shows that discrete linear features with lengths distributed as a power-law appear to be the most consistent with observations of the flow dimension in fractured dolomite aquifers.

  9. Examination of magnetic resonance soundings in the Central Platter River Basin for ground water model enhancements

    NASA Astrophysics Data System (ADS)

    Abraham, J. D.; Kress, W. H.; Cannia, J. C.; Steele, G. V.; Smith, B. D.; Woodward, D.

    2008-12-01

    In 2007, the USGS in cooperation with the Central Platte Natural Resources District, central Nebraska, initiated a four year study to test the usefulness of magnetic resonance rounding (MRS) to gather information on aquifer characteristics. Magnetic resonance sounding is a ground surface applied tool which has the potential to measure hydraulic conductivity at depth using noninvasive means. This in turn will provide a low cost alternative to traditional aquifer tests. MRS also will allow for collection of large data sets of aquifer properties during short periods of time. The work is under way in Dawson County near Lexington, Nebraska to characterize the hydrogeology of the Quaternary-age alluvial and underlying Tertiary-age Ogallala Group aquifers that occur within the Platte River Valley. This county was selected because it lies in an area of Nebraska that has major groundwater- surface water management issues which have stimulated the development of regional and local groundwater models. Data used to evaluate the MRS during this study were derived from traditional constant discharge aquifer tests, borehole flow meter tests, lithologic descriptions, borehole geophysics, and time-domain electromagnetic soundings. This study presents methods and interpretation of MRS. The MRS-derived hydraulic conductivity data will be compared to hydraulic conductivity data from two separate constant discharge pumping tests of the alluvium and Ogallala Group aquifers at Site 72 The MRS-derived hydraulic conductivity data will also be compared to conductivity estimates based on data from a borehole flow meter test. This information can potentially be incorporated into groundwater models of the area to provide improved data sets of aquifer characteristics. The research will document an integrated MRS, surface geophysical, borehole geophysical, borehole flow meter and aquifer test approach in which the hydrostratigraphy of the Platte River alluvial aquifer and Ogallala aquifer can be described.

  10. Analysis and interpretation of data obtained in tests of the geothermal aquifer at Klamath Falls, Oregon

    USGS Publications Warehouse

    Sammel, E.A.

    1984-01-01

    Water with temperatures to 130 C occurs in an extensive, heterogeneous aquifer at depths of a few hundred to nearly 2,000 feet. Chemical and isotopic analyses suggest that 190 C water mixes with cooler recharge water in a ratio of about 2 to 3 in zone within and beneath the aquifer. The water spreads from a fault zone and is tapped for space heating by more than 450 wells over a 2 square-mile area. Data obtained during a 50-day pumping and reinjection test in July and August, 1983, were fitted to theoretical double-porosity type curves. Predictions of water-level changes were made for two hypothetical pumping and reinjection schemes. It was determined that reinjection can generally offset declines due to pumping, although water levels will decline near pumped wells and will rise near injection wells. Tracer tests confirmed the double-porosity behavior of the aquifer. Discharge from thermal wells averages about 540 gallons per minute and heat discharge is about 18 x 10 to the 12th power British Thermal Units per year. Down-hole heat exchangers discharge about 13 x 10 to the 10th power British Thermal Units per year. Additional development probably is feasible. (USGS)

  11. A quantitative analysis of hydraulic interaction processes in stream-aquifer systems

    DOE PAGES

    Wang, Wenke; Dai, Zhenxue; Zhao, Yaqian; ...

    2016-01-28

    The hydraulic relationship between the stream and aquifer can be altered from hydraulic connection to disconnection when the pumping rate exceeds the maximum seepage flux of the streambed. This study proposes to quantitatively analyze the physical processes of stream-aquifer systems from connection to disconnection. A free water table equation is adopted to clarify under what conditions a stream starts to separate hydraulically from an aquifer. Both the theoretical analysis and laboratory tests have demonstrated that the hydraulic connectedness of the stream-aquifer system can reach a critical disconnection state when the horizontal hydraulic gradient at the free water surface is equalmore » to zero and the vertical is equal to 1. A boundary-value problem for movement of the critical point of disconnection is established for an analytical solution of the inverted water table movement beneath the stream. The result indicates that the maximum distance or thickness of the inverted water table is equal to the water depth in the stream, and at a steady state of disconnection, the maximum hydraulic gradient at the streambed center is 2. In conclusion, this study helps us to understand the hydraulic phenomena of water flow near streams and accurately assess surface water and groundwater resources.« less

  12. Hydraulic tests in highly permeable aquifers

    NASA Astrophysics Data System (ADS)

    Butler, James J.; Zhan, Xiaoyong

    2004-12-01

    A semianalytical solution is presented for a mathematical model describing the flow of groundwater in response to a slug or pumping test in a highly permeable, confined aquifer. This solution, which is appropriate for wells of any degree of penetration and incorporates inertial mechanisms at both the test and observation wells, can be used to gain new insights into hydraulic tests in highly permeable settings. The oscillatory character of slug- and pumping-induced responses will vary considerably across a site, even in an essentially homogeneous formation, when wells of different radii, depths, and screen lengths are used. Thus variations in the oscillatory character of responses do not necessarily indicate variations in hydraulic conductivity (K). Existing models for slug tests in partially penetrating wells in high-K aquifers neglect the storage properties of the media. That assumption, however, appears reasonable for a wide range of common conditions. Unlike in less permeable formations, drawdown at an observation well in a high-K aquifer will be affected by head losses in the pumping well. Those losses, which affect the form of the pumping-induced oscillations, can be difficult to characterize. Thus analyses of observation-well drawdown should utilize data from the period after the oscillations have dissipated whenever possible. Although inertial mechanisms can have a large impact on early-time drawdown, that impact decreases rapidly with duration of pumping and distance to the observation well. Conventional methods that do not consider inertial mechanisms should therefore be viable options for the analysis of drawdown data at moderate to large times.

  13. Hydraulic tests in highly permeable aquifers

    USGS Publications Warehouse

    Butler, James J.; Zhan, Xiaoyong

    2004-01-01

    A semianalytical solution is presented for a mathematical model describing the flow of groundwater in response to a slug or pumping test in a highly permeable, confined aquifer. This solution, which is appropriate for wells of any degree of penetration and incorporates inertial mechanisms at both the test and observation wells, can be used to gain new insights into hydraulic tests in highly permeable settings. The oscillatory character of slug‐ and pumping‐induced responses will vary considerably across a site, even in an essentially homogeneous formation, when wells of different radii, depths, and screen lengths are used. Thus variations in the oscillatory character of responses do not necessarily indicate variations in hydraulic conductivity (K). Existing models for slug tests in partially penetrating wells in high‐K aquifers neglect the storage properties of the media. That assumption, however, appears reasonable for a wide range of common conditions. Unlike in less permeable formations, drawdown at an observation well in a high‐K aquifer will be affected by head losses in the pumping well. Those losses, which affect the form of the pumping‐induced oscillations, can be difficult to characterize. Thus analyses of observation‐well drawdown should utilize data from the period after the oscillations have dissipated whenever possible. Although inertial mechanisms can have a large impact on early‐time drawdown, that impact decreases rapidly with duration of pumping and distance to the observation well. Conventional methods that do not consider inertial mechanisms should therefore be viable options for the analysis of drawdown data at moderate to large times.

  14. Effect of faults on fluid flow and chloride contamination in a carbonate aquifer system

    USGS Publications Warehouse

    Maslia, M.L.; Prowell, D.C.

    1990-01-01

    A unified, multidiscipline hypothesis is proposed to explain the anomalous pattern by which chloride has been found in water of the Upper Floridan aquifer in Brunswick, Glynn County, Georgia. Analyses of geophysical, hydraulic, water chemistry, and aquifer test data using the equivalent porous medium (EPM) approach are used to support the hypothesis and to improve further the understanding of the fracture-flow system in this area. Using the data presented herein we show that: (1) four major northeast-southwest trending faults, capable of affecting the flow system of the Upper Floridan aquifer, can be inferred from structural analysis of geophysical data and from regional fault patterns; (2) the proposed faults account for the anomalous northeastward elongation of the potentiometric surface of the Upper Floridan aquifer; (3) the faults breach the nearly impermeable units that confine the Upper Floridan aquifer from below, allowing substantial quantities of water to leak vertically upward; as a result, aquifer transmissivity need not be excessively large (as previously reported) to sustain the heavy, long-term pumpage at Brunswick without developing a steep cone of depression in the potentiometric surface; (4) increased fracturing at the intersection of the faults enhances the development of conduits that allow the upward migration of high-chloride water in response to pumping from the Upper Floridan aquifer; and (5) the anomalous movement of the chloride plume is almost entirely controlled by the faults. ?? 1990.

  15. Factor weighting in DRASTIC modeling.

    PubMed

    Pacheco, F A L; Pires, L M G R; Santos, R M B; Sanches Fernandes, L F

    2015-02-01

    Evaluation of aquifer vulnerability comprehends the integration of very diverse data, including soil characteristics (texture), hydrologic settings (recharge), aquifer properties (hydraulic conductivity), environmental parameters (relief), and ground water quality (nitrate contamination). It is therefore a multi-geosphere problem to be handled by a multidisciplinary team. The DRASTIC model remains the most popular technique in use for aquifer vulnerability assessments. The algorithm calculates an intrinsic vulnerability index based on a weighted addition of seven factors. In many studies, the method is subject to adjustments, especially in the factor weights, to meet the particularities of the studied regions. However, adjustments made by different techniques may lead to markedly different vulnerabilities and hence to insecurity in the selection of an appropriate technique. This paper reports the comparison of 5 weighting techniques, an enterprise not attempted before. The studied area comprises 26 aquifer systems located in Portugal. The tested approaches include: the Delphi consensus (original DRASTIC, used as reference), Sensitivity Analysis, Spearman correlations, Logistic Regression and Correspondence Analysis (used as adjustment techniques). In all cases but Sensitivity Analysis, adjustment techniques have privileged the factors representing soil characteristics, hydrologic settings, aquifer properties and environmental parameters, by leveling their weights to ≈4.4, and have subordinated the factors describing the aquifer media by downgrading their weights to ≈1.5. Logistic Regression predicts the highest and Sensitivity Analysis the lowest vulnerabilities. Overall, the vulnerability indices may be separated by a maximum value of 51 points. This represents an uncertainty of 2.5 vulnerability classes, because they are 20 points wide. Given this ambiguity, the selection of a weighting technique to integrate a vulnerability index may require additional expertise to be set up satisfactorily. Following a general criterion that weights must be proportional to the range of the ratings, Correspondence Analysis may be recommended as the best adjustment technique. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Aquifer test at well SMW-1 near Moenkopi, Arizona

    USGS Publications Warehouse

    Carruth, Rob; Bills, Donald J.

    2012-01-01

    The Hopi villages of Lower Moencopi and Upper Moenkopi are on the Hopi Indian Reservation south of Tuba City in northern Arizona. These adjacent Hopi villages, located west and north of the confluence of Pasture Canyon Wash and Moenkopi Wash, are dependent on groundwater withdrawals from three wells that penetrate the N aquifer and from two springs that discharge from the N aquifer. The N aquifer is the principal aquifer in this region of northern Arizona and is composed of thick beds of sandstone between less permeable layers of siltstone and mudstone. The fine-grained character of the N aquifer inhibits rapid movement of water and large yields to wells; however, the aquifer is moderately productive at yields generally less than 25 gallons per minute in the study area. In recent years, the water level has declined in the three public-supply wells and the flow from the springs has decreased, causing concern that the current water supply will not be able to accommodate peak demand and allow for residential and economic growth. In addition to the challenge imposed by declining groundwater levels, the water-supply wells and springs are located about 2 miles downgradient from the Tuba City Landfill site where studies are ongoing to determine if uranium and other metals in groundwater beneath the landfill are higher than regional concentrations in the N aquifer. In August 2008, the U.S. Geological Survey, in cooperation with the Hopi Tribe, conducted an aquifer test on well SMW-1, designed to help the Hopi Tribe determine the potential yield and water quality of the N aquifer south of Moenkopi Wash as a possible source of additional water supply. Well SMW-1 was drilled south of Moenkopi Wash to a depth of 760 feet below land surface before being backfilled and cased to about 300 feet. The well penetrates, in descending order, the Navajo Sandstone and the Kayenta Formation, both units of the N aquifer. The pre-test water level in the well was 99.15 feet below land surface. A 9.25-hour step-drawdown test and a 72-hour constant-rate test followed by recovery tests were used to investigate the performance of the test well and to estimate the transmissivity and potential yield of the N aquifer south of Moenkopi Wash. The test data were analyzed using the Cooper-Jacob method adjusted for confined conditions, the Papadopulos-Cooper method that accounts for wellbore storage, and the Theis method on the recovery data. Results of the tests indicate that in the vicinity of the well, the N aquifer has a transmissivity of about 50 feet squared per day. The test well, as completed, should yield about 15 gallons per minute with about 75 feet of drawdown (less than half of the available saturated thickness of the aquifer at the well).

  17. Ground-water resources of southern Tangipahoa Parish and adjacent areas, Louisiana

    USGS Publications Warehouse

    Rapp, T.R.

    1994-01-01

    Groundwater resources in southern Tangipahoa Parish and adjacent areas were studied to determine their potential for development as an alternative to the Mississippi River as a water-supply source for Jefferson Parish. Eight major aquifers consisting of thick sand units that underlie the study area are, in descending order: (1) shallow, (2) upper Ponchatoula, (3) lower Ponchatoula, (4) Abita, (5) Covington, (6) Tchefuncta, (7) Hammond, and (8) Amite. A fault zone, referred to as the Baton Rouge fault, crosses southern Tangipahoa Parish. Analyses of geophysical logs indicated that the deep aquifers south of the fault zone had been displaced from 350 to 400 feet, and that the deeper aquifers were not in hydraulic connection with the flow system north of the fault. The groundwater resources of southeastern Louisiana are immense and the quality of groundwater in Tangipahoa Parish is suitable for most uses. The quality of water in these aquifers generally meets the U.S. Environmental Protection Agency's standards for public supply. The hydrologic system underlying Tangipahoa Parish and adjacent areas in 1990 supplied about 19 Mgal/d of water that was suitable for public supply. However, substantial increases in pumping from the aquifer system would result in renewed water-level declines throughout the hydrologic system until a new equilibrium is established. A test we11 in southern Tangipahoa Parish, penetrated all eight aquifers. Total thickness of freshwater sand beds penetrated by the 3003-ft test hole was more than 1900 ft. Resistivity values from an electric log of the test typically averaged 200 ohm-meters, which indicates that the water has low dissolved-solids and chloride concentrations. An analysis of the Abita aquifer at Ruddock in St. John the Baptist Parish, for two of three hypothetical well fields, indicated that for a hypothetical we11 field with a pumping rate of 112 Mgal/d, the freshwater/saltwater interface could arrive at the outer perimeter we11 in 10 to 14 years. The 1990 location of the interface in the Abita aquifer is 1.9 mi from the southernmost part of the potential location of the 112 Mgal/d well field.

  18. A field assessment of the value of steady shape hydraulic tomography for characterization of aquifer heterogeneities

    USGS Publications Warehouse

    Bohling, Geoffrey C.; Butler, James J.; Zhan, Xiaoyong; Knoll, Michael D.

    2007-01-01

    Hydraulic tomography is a promising approach for obtaining information on variations in hydraulic conductivity on the scale of relevance for contaminant transport investigations. This approach involves performing a series of pumping tests in a format similar to tomography. We present a field‐scale assessment of hydraulic tomography in a porous aquifer, with an emphasis on the steady shape analysis methodology. The hydraulic conductivity (K) estimates from steady shape and transient analyses of the tomographic data compare well with those from a tracer test and direct‐push permeameter tests, providing a field validation of the method. Zonations based on equal‐thickness layers and cross‐hole radar surveys are used to regularize the inverse problem. The results indicate that the radar surveys provide some useful information regarding the geometry of the K field. The steady shape analysis provides results similar to the transient analysis at a fraction of the computational burden. This study clearly demonstrates the advantages of hydraulic tomography over conventional pumping tests, which provide only large‐scale averages, and small‐scale hydraulic tests (e.g., slug tests), which cannot assess strata connectivity and may fail to sample the most important pathways or barriers to flow.

  19. Electric analog of three-dimensional flow to wells and its application to unconfined aquifers

    USGS Publications Warehouse

    Stallman, Robert W.

    1963-01-01

    Electric-analog design criteria are established from the differential equations of ground-water flow for analyzing pumping-test data. A convenient analog design was obtained by transforming the cylindrical equation of flow to a rectilinear form. The design criteria were applied in the construction of an electric analog, which was used for studying pumping-test data collected near Grand Island, Nebr. Data analysis indicated (1) vertical flow components near pumping wells in unconfined aquifers may be much more significant in the control of water-table decline than radial flow components for as much as a day of pumping; (2) the specific yield during the first few minutes of pumping appears to be a very small fraction of that observed after pumping for more than 1 day; and (3) estimates of specific yield made from model studies seem much more sensitive to variations in assumed flow conditions than are estimates of permeability. Analysis of pumping-test data where vertical flow components are important requires that the degree of anisotropy be known. A procedure for computing anisotropy directly from drawdowns observed at five points was developed. Results obtained in the analog study emphasize the futility of calculating unconfined aquifer properties from pumping tests of short duration by means of equations based on the assumptions that vertical flow components are negligible and specific yield is constant.

  20. A Method to Estimate the Hydraulic Conductivity of the Ground by TRT Analysis.

    PubMed

    Liuzzo Scorpo, Alberto; Nordell, Bo; Gehlin, Signhild

    2017-01-01

    The knowledge of hydraulic properties of aquifers is important in many engineering applications. Careful design of ground-coupled heat exchangers requires that the hydraulic characteristics and thermal properties of the aquifer must be well understood. Knowledge of groundwater flow rate and aquifer thermal properties is the basis for proper design of such plants. Different methods have been developed in order to estimate hydraulic conductivity by evaluating the transport of various tracers (chemical, heat etc.); thermal response testing (TRT) is a specific type of heat tracer that allows including the hydraulic properties in an effective thermal conductivity value. Starting from these considerations, an expeditious, graphical method was proposed to estimate the hydraulic conductivity of the aquifer, using TRT data and plausible assumption. Suggested method, which is not yet verified or proven to be reliable, should be encouraging further studies and development in this direction. © 2016, National Ground Water Association.

  1. Constant-head pumping test of a multiaquifer well to determine characteristics of individual aquifers

    USGS Publications Warehouse

    Bennett, Gordon D.; Patten, E.P.

    1962-01-01

    This report describes the theory and field procedures for determining the transmissibility and storage coefficients and the original hydrostatic head of each aquifer penetrated by a multiaquifer well. The procedure involves pumping the well in such a manner that the drawdown of water level is constant while the discharges of the different aquifers are measured by means of borehole flowmeters. The theory is developed by analogy to the heat-flow problem solved by Smith. The internal discharge between aquifers after the well is completed is analyzed as the first step. Pumping at constant, drawdown constitutes the second step. Transmissibility and storage coefficients are determined by a method described by Jacob and Lohman, after the original internal discharge to or from the aquifer has been compensated for in the calculations. The original hydrostatic head of each aquifer is then determined by resubstituting the transmissibility and storage coefficients into the first step of the analysis. The method was tested on a well in Chester County, Pa., but the results were not entirely satisfactory, owing to the lack of sufficiently accurate methods of flow measurement and, probably, to the effects of entrance losses in the well. The determinations of the transmissibility coefficient and static head can be accepted as having order-of-magnitude significance, but the determinations of the storage coefficient, which is highly sensitive to experimental error, must be rejected. It is felt that better results may be achieved in the future, as more reliable devices for metering the flow become available and as more is learned concerning the nature of entrance losses. If accurate data can be obtained, recently developed techniques of digital or analog computation may permit determination of the response of each aquifer in the well to any form of pumping.

  2. Characterization of shallow unconsolidated aquifers in West Africa using different hydrogeological data sources as a contribution to the promotion of manual drilling and low cost techniques for groundwater exploration

    NASA Astrophysics Data System (ADS)

    Fussi, Fabio; Fumagalli, Letizia; Bonomi, Tullia; Kane, Cheikh H.; Fava, Francesco; Di Mauro, Biagio; Hamidou, Barry; Niang, Magatte; Wade, Souleye; Colombo, Roberto

    2016-04-01

    Manual drilling refers to several drilling methods that rely on human energy to construct a borehole and complete a water supply (Danert, 2015). It can be an effective strategy to increase access to groundwater in low income countries , but manual drilling can be applied only where shallow geological layers are relatively soft and water table is not too deep. It is important therefore to identify those zones where shallow hydrogeological conditions are suitable, investigating the characteristics of shallow porous aquifers. Existing hydrogeological studies are generally focused in the characterization of deep fractures aquifers, more productive and able to ensure water supply for large settlements. Information concerning shallow porous aquifers are limited. This research has been carried out in two different study areas in West Africa (North-Western Senegal and Eastern Guinea). Aim of the research is the characterization of shallow aquifer using different methods and the identification of hydrogeological condition suitable for manual drilling implementation. Three different methods to estimate geometry and hydraulic properties of shallow unconsolidated aquifers have been used: The first method is based on the analysis of stratigraphic data obtained from borehole logs of the national water point database in both countries. The following steps have been implemented on the original information using the software TANGAFRIC, specifically designed for this study: a) identification of most frequent terms used for hydrogeological description in Senegal and Guinea database; b) definition of standard categories and manual codification of data; c) automatic extraction of average distribution of textural classes at different depth intervals in the unconsolidated aquifer; d) estimation of hydraulic parameters using conversion tables between texture and hydraulic conductivity available in the literature. . The second method is based on the interpretation of pump and recovery test in large diameter wells. K values obtained from these tests provide direct information on hydraulic parameters of shallow porous aquifers (while pump tests data obtained from deep mechanized boreholes, exploiting fractured aquifers, cannot be considered representative for the target shallow aquifer of manual drilling). The third method is based on the interpretation of stratigraphic logs and simplified pump test from manual drilled wells carried out since 2012 in Guinea. In this country a standard and systematic procedure to collect hydrogeological data from these wells (therefore indicating properties of shallow aquifer) has been put in place in 2011; it is considered one of the best example worldwide about technical data collection and systematization from manual drilling activities, but its development has been stopped because of the outbreak of Ebola in this country. The integration of these 3 methods allow to estimate geometry and hydraulic behavior of shallow unconsolidated aquifer, identifying those areas where manual drilling is feasible and estimating potential yield that can be extracted. In the mean time this research provides relevant indications concerning the use of data obtained from low cost open hand dug or manually drilled wells (rarely used in hydrogeological research) for groundwater exploration of shallow aquifers.

  3. Geohydrology and water quality of stratified-drift aquifers in the lower Merrimack and coastal river basins, southeastern New Hampshire

    USGS Publications Warehouse

    Stekl, Peter J.; Flanagan, Sarah M.

    1992-01-01

    Communities in the lower Merrimack River basin and coastal river basins of southeastern New Hampshire are experiencing increased demands for water because of a rapid increase in population. The population in 1987 was 225,495 and is expected to increase by 30 percent during the next decade. As of 1987, five towns used the stratified-drift aquifers for municipal supply and withdrew an estimated 6 million gallons per day. Four towns used the bedrock aquifer for municipal supply and withdrew an average of 1 .6 million gallons per day. Stratified-drift deposits cover 78 of the 327 square miles of the study area. These deposits are generally less than 10 square miles in areal extent, and their saturated thickness ranges front less than 20 feet to as much as 100 feet . Transinissivity exceeds 4,000 square feet per day in several locations. Stratified-drift aquifers in the eastern part are predominantly small ice-contact deposits surrounded by marine sediments or till of low hydraulic conductivity. Stratified-drift aquifers in the western part consist of ice-contact and proglacial deposits that are large in areal extent and are commonly in contact with surface-water bodies. Five stratified-drift aquifers, in the towns of Derry, Windham, Kingston, North Hampton, and Greenland, have the greatest potential to supply additional amounts of water. Potential yields and contributing areas of hypothetical supply wells were estimated for an aquifer in Windham near Cobbetts Pond and for an aquifer in Kingston along the Powwow River by use of a method analogous to superposition in conjunction with a numerical ground-waterflow model. The potential yield is estimated to be 0 .6 million gallons per day for the Windham-Cobbetts Pond aquifer and 4 .0 million gallons per day for the Kingston-Powwow River aquifer. Contributing recharge area for supply wells is estimated to be 1.6 square miles in the Windham-Cobbetts Pond aquifer and 4.9 square miles in the Kingston-Powwow River aquifer. Analyses of water samples from 30 wells indicate that the water quality in the basins studied is generally suitable for drinking and other domestic purposes. Concentrations of iron and manganese exceeded the U.S . Environmental Protection Agency's (USEPA) and the New Hampshire Water Supply Engineering Bureau's secondary maximum contaminant levels for drinking water in 20 samples. With one exception, concentrations of volatile organic compounds at all wells sampled met New Hampshire Water Supply and Engineering Bureau's drinking-water standards. At one well, trichloroethylene was detected at a concentration of 5.7 micrograms per liter. Ground-water contamination has been detected at several hazardous-waste sites in the study area. Currently, 5 sites are on the USEPA's National Priority List of superfund sites, 10 sites are Resource Conservation and Recovery Act of 1976 sites, and 1 site is a Department of Defense hazardous-waste site of stratigraphic layers is a product of a material's density and the velocity at which sound travels through that material . The reflected signals return to the hydrophones at the water surface and are then filtered, amplified, and displayed graphically on the chart recorder to allow interpretation of aquifer stratigraphy and bedrock depths. Lithologic data from nearby wells and test holes were used as control points to check the interpretation of the reflection profiles. Test drilling was done at 66 locations (pls . 1-3) to determine sediment grain size, stratigraphy, depth to water table, depth to bedrock, and ground water quality . A 6-inch-diameter, hollow-stem auger was used for test drilling . Split-spoon samples of subsurface materials collected at specific depths were used to evaluate the grain-size characteristics and identify the stratigraphic sequence of materials comprising the aquifers . Thirty-eight test holes cased with a 2-inch-diameter polyvinyl-chloride (PVC) pipe and slotted screens were used to make ground-water-level measurements and collect ground-water-quality samples. Surface-water-discharge measurements were made at 16 sites during low flow when the surface water is primarily ground-water discharge . These low-flow measurements indicate quantities of ground water potentially available from aquifers. Hydraulic conductivities of aquifer materials were estimated from grain-size-distribution data from 61 samples of stratified drift . Transmissivity was estimated from well logs by assigning hydraulic conductivity to specific well-log intervals, multiplying by the saturated thickness of the interval, and summing the results . Additional transmissivity values were obtained from an analysis of specific capacity and aquifer-test data. Long-term aquifer yields and contributing areas to hypothetical supply wells were estimated by application of a method that is analogous to super position and incorporates a ground-water-flow model developed by McDonald and Harbaugh (1988) . This method was applied to two aquifers judged to have the best potential for providing additional ground-water supplies. Samples of ground water from 26 test wells and 4 municipal wells were collected in March and August 1987 for analysis of common inorganic, organic, and volatile organic constituents. Methods for collecting and analyzing the samples are described by Fishman and Freidman (1989) . The water-quality results from the well samples were used to characterize background water quality in the stratified-drift aquifers.

  4. Cross-borehole slug test analysis in a fractured limestone aquifer

    NASA Astrophysics Data System (ADS)

    Audouin, Olivier; Bodin, Jacques

    2008-01-01

    SummaryThis work proposes new semi-analytical solutions for the interpretation of cross-borehole slug tests in fractured media. Our model is an extension of a previous work by Barker [Barker, J.A., 1988. A generalized radial flow model for hydraulic tests in fractured rock. Water Resources Research 24 (10), 1796-1804; Butler Jr., J.J., Zhan X., 2004. Hydraulic tests in highly permeable aquifers. Water Resources Research 40, W12402. doi:10.1029/2003/WR002998]. It includes inertial effects at both test and observation wells and a fractional flow dimension in the aquifer. The model has five fitting parameters: flow dimension n, hydraulic conductivity K, specific storage coefficient Ss, and effective lengths of test well Le and of observation well Leo. The results of a sensitivity analysis show that the most sensitive parameter is the flow dimension n. The model sensitivity to other parameters may be ranked as follows: K > Le ˜ Leo > Ss. The sensitivity to aquifer storage remains one or two orders of magnitude lower than that to other parameters. The model has been coupled to an automatic inversion algorithm for facilitating the interpretation of real field data. This inversion algorithm is based on a Gauss-Newton optimization procedure conditioned by re-scaled sensitivities. It has been used to interpret successfully cross-borehole slug test data from the Hydrogeological Experimental Site (HES) of Poitiers, France, consisting of fractured and karstic limestones. HES data provide flow dimension values ranging between 1.6 and 2.5, and hydraulic conductivity values ranging between 4.4 × 10 -5 and 7.7 × 10 -4 m s -1. These values are consistent with previous interpretations of single-well slug tests. The results of the sensitivity analysis are confirmed by calculations of relative errors on parameter estimates, which show that accuracy on n and K is below 20% and that on Ss is about one order of magnitude. The K-values interpreted from cross-borehole slug tests are one order of magnitude higher than those previously interpreted from interference pumping tests. These findings suggest that cross-borehole slug tests focus on preferential flowpath networks made by fractures and karstic channels, i.e. the head perturbation induced by a slug test propagates only through those flowpaths with the lowest hydraulic resistance. As a result, cross-borehole slug tests are expected to identify the hydrodynamic properties of karstic-channels and fracture flowpaths, and may be considered as complementary to pumping tests which more likely provide bulk properties of the whole fracture/karstic-channel/matrix system.

  5. Use of computer programs STLK1 and STWT1 for analysis of stream-aquifer hydraulic interaction

    USGS Publications Warehouse

    Desimone, Leslie A.; Barlow, Paul M.

    1999-01-01

    Quantifying the hydraulic interaction of aquifers and streams is important in the analysis of stream base fow, flood-wave effects, and contaminant transport between surface- and ground-water systems. This report describes the use of two computer programs, STLK1 and STWT1, to analyze the hydraulic interaction of streams with confined, leaky, and water-table aquifers during periods of stream-stage fuctuations and uniform, areal recharge. The computer programs are based on analytical solutions to the ground-water-flow equation in stream-aquifer settings and calculate ground-water levels, seepage rates across the stream-aquifer boundary, and bank storage that result from arbitrarily varying stream stage or recharge. Analysis of idealized, hypothetical stream-aquifer systems is used to show how aquifer type, aquifer boundaries, and aquifer and streambank hydraulic properties affect aquifer response to stresses. Published data from alluvial and stratifed-drift aquifers in Kentucky, Massachusetts, and Iowa are used to demonstrate application of the programs to field settings. Analytical models of these three stream-aquifer systems are developed on the basis of available hydrogeologic information. Stream-stage fluctuations and recharge are applied to the systems as hydraulic stresses. The models are calibrated by matching ground-water levels calculated with computer program STLK1 or STWT1 to measured ground-water levels. The analytical models are used to estimate hydraulic properties of the aquifer, aquitard, and streambank; to evaluate hydrologic conditions in the aquifer; and to estimate seepage rates and bank-storage volumes resulting from flood waves and recharge. Analysis of field examples demonstrates the accuracy and limitations of the analytical solutions and programs when applied to actual ground-water systems and the potential uses of the analytical methods as alternatives to numerical modeling for quantifying stream-aquifer interactions.

  6. Coupled modelling of groundwater flow-heat transport for assessing river-aquifer interactions

    NASA Astrophysics Data System (ADS)

    Engeler, I.; Hendricks Franssen, H. J.; Müller, R.; Stauffer, F.

    2010-05-01

    A three-dimensional finite element model for coupled variably saturated groundwater flow and heat transport was developed for the aquifer below the city of Zurich. The piezometric heads in the aquifer are strongly influenced by the river Limmat. In the model region, the river Limmat looses water to the aquifer. The river-aquifer interaction was modelled with the standard linear leakage concept. Coupling was implemented by considering temperature dependence of the hydraulic conductivity and of the leakage coefficient (via water viscosity) and density dependent transport. Calibration was performed for isothermal conditions by inverse modelling using the pilot point method. Independent model testing was carried out with help of the available dense monitoring network for piezometric heads and groundwater temperature. The model was tested by residuals analysis with the help of measurements for both groundwater temperature and head. The comparison of model results and measurements showed high accuracy for temperature except for the Southern part of the model area, where important geological heterogeneity is expected, which could not be reproduced by the model. The comparison of simulated and measured head showed that especially in the vicinity of river Limmat model results were improved by a temperature dependent leakage coefficient. Residuals were reduced up to 30% compared to isothermal leakage coefficients. This holds particularly for regions, where the river stage is considerably above the groundwater level. Furthermore additional analysis confirmed prior findings, that seepage rates during flood events cannot be reproduced with the implemented linear leakage-concept. Infiltration during flood events is larger than expected, which can be potentially attributed to additional infiltration areas. It is concluded that the temperature dependent leakage concept improves the model results for this study area significantly, and that we expect that this is also for other areas the case.

  7. Design of a Real-Time Ground-Water Level Monitoring Network and Portrayal of Hydrologic Data in Southern Florida

    USGS Publications Warehouse

    Prinos, Scott T.; Lietz, A.C.; Irvin, R.B.

    2002-01-01

    Ground-water resources in southern Florida are under increasing stress caused by a rapid growth in population. As a result of increased demands on aquifers, water managers need more timely and accurate assessments of ground-water conditions in order to avoid or reduce adverse effects such as saltwater intrusion, loss of pumpage in residential water-supply wells, land-surface subsidence, and aquifer compaction. Hydrologic data were analyzed from three aquifer systems in southern Florida: the surficial aquifer system, which includes the Biscayne aquifer; the intermediate aquifer system, which includes the sandstone and mid-Hawthorn aquifers; and the Florida aquifer system represented by the lower Hawthorn producing zone. Long-term water-level trends were analyzed using the Seasonal Kendall trend test in 83 monitoring wells with a daily-value record spanning 26 years (1974-99). The majority of the wells with data for this period were in the Biscayne aquifer in southeastern Florida. Only 14 wells in southwestern Florida aquifers and 9 in the surficial aquifer system of Martin and Palm Beach Counties had data for the full period. Because many monitoring wells did not have data for this full period, several shorter periods were evaluated as well. The trend tests revealed small but statistically significant upward trends in most aquifers, but large and localized downward trends in the sandstone and mid-Hawthorn aquifers. Monthly means of maximum daily water levels from 246 wells were compared to monthly rainfall totals from rainfall stations in southwestern and southeastern Florida in order to determine which monitoring wells most clearly indicated decreases in water levels that corresponded to prolonged rainfall shortages. Of this total, 104 wells had periods of record over 20 years (after considering missing record) and could be compared against several drought periods. After factors such as lag, seasonal cyclicity, and cumulative functions were considered, the timing of minimum values of water level from 15 ground-water monitoring wells and average minimum rainfall values agreed 57 to 62 percent of the time over a 20 to 26 year period. On average, the timing of water-level minimums and rainfall minimums agreed about 52 percent of the time, and in some cases only agreed 29 percent of the time. A regression analysis was used to evaluate daily water levels from 203 monitoring wells that are currently, or recently had been, part of the network to determine which wells were most representative of each aquifer. The regression also was used to determine which wells provided data that could be used to provide estimations of water levels at other wells in the aquifer with a coefficient of determination (R2 value) from the regression of 0.64 or greater. In all, the regression analysis alone indicated that 35 wells, generally with 10 years or more of data, could be used to directly monitor water levels or to estimate water levels at 180 of 203 wells (89 percent of the network). Ultimately, factors such as existing instrumentation, well construction, long-term water-level trends, and variations of water level and chloride concentration were considered together with the R2 results in designing the final network. The Seasonal Kendall trend test was used to examine trends in ground-water chloride concentrations in 113 wells. Of these wells, 61 showed statistically significant trends. Fifty-six percent (34 of 61 wells) of the observed trends in chloride concentration were upward and 44 percent (27 of 61 wells) were downward. The relation between water level and chloride concentration in 114 ground-water wells was examined using Spearman's r and Pearson's r correlation coefficients. Statistically significant results showed both positive and negative relations. Based on the results of statistical analyses, period of record, well construction, and existing satellite telemetry, 33 monitoring wells were selected that could be used to a

  8. Hydrogeology and simulation of ground-water flow at US Marine Corps Air Station, Cherry Point, North Carolina, 1987-90

    USGS Publications Warehouse

    Eimers, J.L.; Daniel, C. C.; Coble, R.W.

    1994-01-01

    Geophysical and lithologic well-log data from 30 wells and chloride data, and water-level data from oil-test wells, supply wells, and observation wells were evaluated to define the hydrogeologic framework at the U.S. Marine Corps Air Station, Cherry Point, North Carolina. Elements of the hydrogeologic framework important to this study include six aquifers and their respective confining units. In descending order, these aquifers are the surficial, Yorktown, Pungo River, upper and lower Castle Hayne, and Beaufort. The upper and lower Castle Hayne and Beaufort aquifers and related confining units are relatively continuous throughout the study area. The surficial, Yorktown, Pungo River, and upper and lower Castle Hayne aquifers contain freshwater. The upper and lower Castle Hayne aquifers serve as the Air Station?s principal supply of freshwater. However, the lower Castle Hayne aquifer contains brackish water near its base and there is potential for upward movement of this water to supply wells completed in this aquifer. The potential for brackish-water encroachment is greatest if wells are screened too deep in the lower Castle Hayne aquifer or if pumping rates are too high. Lateral movement of brackish water into aquifers incised by estuarine streams is also possible if ground-water flow gradients toward these bodies are reversed by pumping. The potential for the reversed movement of water from the surficial aquifer downward to the water-supply aquifer is greatest in areas where clay confining units are missing. These missing clay units could indicate the presence of a paleochannel of the Neuse River. A quasi three-dimensional finite-difference ground-water flow model was constructed and calibrated to simulate conditions at and in the vicinity of the Air Station for the period of 1987-90. Comparisons of 94 observed and computed heads were made, and the average difference between them is -0.2 feet with a root mean square error of 5.7 feet. An analysis was made to evaluate the sensitivity of the model to the absence of the Yorktown and Pungo River confining units in a 1-square-mile area in the southern part of the Air Station. This analysis resulted in a maximum simulated head increase of 2 feet in one 0.11-square-mile model cell in the Pungo River aquifer.

  9. Hydrogeology of the area near the J4 test cell, Arnold Air Force Base, Tennessee

    USGS Publications Warehouse

    Haugh, C.J.

    1996-01-01

    The U.S. Air Force operates a major aerospace systems testing facility at Arnold Engineering Development Center (AEDC) in Coffee County, Tennessee. Dewatering operations at one of the test facilities, the J4 test cell, has affected the local ground-water hydrology. The J4 test cell is approximately 100 feet in diameter, extends approximately 250 feet below land surface, and penetrates several aquifers. Ground water is pumped continuously from around the test cell to keep the cell structurally intact. Because of the test cell's depth, dewatering has depressed water levels in the aquifers surrounding the site. The depressions that have developed exhibit anisotropy that is controlled by zones of high permeability in the aquifers. Additionally, contaminants - predominately volatile organic compounds - are present in the ground-water discharge from the test cell and in ground water at several other Installation Restoration Program (IRP) sites within the AEDC facility. The dewatering activities at J4 are drawing these contaminants from the nearby sites. The effects of dewatering at the J4 test cell were investigated by studying the lithologic and hydraulic characteristics of the aquifers, investigating the anisotropy and zones of secondary permeability using geophysical techniques, mapping the potentiometric surfaces of the underlying aquifers, and developing a conceptual model of the ground-water-flow system local to the test cell. Contour maps of the potentiometric surfaces in the shallow, Manchester, and Fort Payne aquifers (collectively, part of the Highland Rim aquifer system) show anisotropic water-level depressions centered on the J4 test cell. This anisotropy is the result of features of high permeability such as chert-gravel zones in the regolith and fractures, joints, and bedding planes in the bedrock. The presence of these features of high permeability in the Manchester aquifer results in complex flow patterns in the Highland Rim aquifers near the J4 test cell. The occurrence, distribution, and orientation of these features has a great effect on ground-water flow to the J4 test cell. The depression caused by dewatering extends out horizontally through the aquifers along the most permeable pathways. Since the aquifers above the Chattanooga Shale are not separated by distinct confining units, areas in adjacent aquifers above and below these zones of high permeability in the Manchester aquifer are also dewatered. Conditions in all Highland Rim aquifers approximate steady-state equilibrium because ground-water withdrawal at the test cell has been continuous since the late 1960's. The average ground-water discharge from the dewatering system at the J4 test cell was 105 gallons per minute, for 1992-95. The ground-water capture areas in each aquifer extend into all or parts of landfill #2 and leaching pit #2 (IRP site 1), the main testing area (IRP site 7), and the old fire training area (IRP site 10). IRP sites 8 and 12 are outside the ground-water capture areas. Of the 35 sampled wells in the J4 area, 10 produced water samples containing chlorinated organic compounds such as 1,2-dichloroethane (1,2-DCA), 1,1-dichloroethylene (1,1-DCE), and trichloroethylene (TCE) in concentrations which exceeded the Tennessee Department of Environment and Conservation Maximum Contaminant Levels (MCL's) for public water-supply systems. The highest concentrations were detected in samples from well AEDC-274 with 45 micrograms per liter (mg/L) 1,2-DCA, 320 mg/L 1,1-DCE, and 1,200 mg/L TCE. These compounds are synthetic and do not occur naturally in the environment. A sample of the ground-water discharge from the J4 test cell also contained concentrations of these compounds that exceed MCL's. Chlorinated organic compounds, including 1,2-DCA; 1,1-DCE; and TCE also have been detected at IRP sites 1, 7, 8, nd 10. The six dewatering wells surrounding the J4 test cell penetrate the Chattanooga Shale and are open to the Highland Rim aquifer system, there

  10. Subsurface storage of freshwater in South Florida; a digital analysis of recoverability

    USGS Publications Warehouse

    Merritt, Michael L.

    1983-01-01

    As part of a feasibility study of cyclic freshwater injection, digital models were implemented to analyze the relation of recovery efficiency to various hydrogeologic conditions which could prevail in brackish aquifers and to various management regimes. The analyses implemented an approach in which the control for sensitivity testing was a hypothetical aquifer representative of potential injection zones in south Florida, and parameter variations in sensitivity tests represented possible variations in aquifer conditions in the area. The permeability of the aquifer determined whether buoyancy stratification could reduce recovery efficiency. The range of permeability leading to buoyancy stratification became lower as resident fluid salinity increased. Thus, recovery efficiency was optimized by both low permeability and low resident fluid density. High levels of simulated hydrodynamic dispersion led to the lowest estimates of recovery efficiency. Advection by regional flow within the artesian injection zone could significantly affect recovery efficiency, depending upon the storage period, the volume injected, and site-specific hydraulic characteristics. Recovery efficiency was unrelated to the rate of injection or withdrawal or to the degree of penetration of permeable layers, and improved with successive cycles of injection and recovery. (USGS)

  11. Analysis of water levels in the Frenchman Flat area, Nevada Test Site

    USGS Publications Warehouse

    Bright, D.J.; Watkins, S.A.; Lisle, B.A.

    2001-01-01

    Analysis of water levels in 21 wells in the Frenchman Flat area, Nevada Test Site, provides information on the accuracy of hydraulic-head calculations, temporal water-level trends, and potential causes of water-level fluctuations. Accurate hydraulic heads are particularly important in Frenchman Flat where the hydraulic gradients are relatively flat (less than 1 foot per mile) in the alluvial aquifer. Temporal water-level trends with magnitudes near or exceeding the regional hydraulic gradient may have a substantial effect on ground-water flow directions. Water-level measurements can be adjusted for the effects of barometric pressure, formation water density (from water-temperature measurements), borehole deviation, and land-surface altitude in selected wells in the Frenchman Flat area. Water levels in one well were adjusted for the effect of density; this adjustment was significantly greater (about 17 feet) than the adjustment of water levels for barometric pressure, borehole deviation, or land-surface altitude (less than about 4 feet). Water-level measurements from five wells exhibited trends that were statistically and hydrologically significant. Statistically significant water-level trends were observed for three wells completed in the alluvial aquifer (WW-5a, UE-5n, and PW-3), for one well completed in the carbonate aquifer (SM-23), and for one well completed in the quartzite confining unit (Army-6a). Potential causes of water-level fluctuations in wells in the Frenchman Flat area include changes in atmospheric conditions (precipitation and barometric pressure), Earth tides, seismic activity, past underground nuclear testing, and nearby pumping. Periodic water-level measurements in some wells completed in the carbonate aquifer indicate cyclic-type water-level fluctuations that generally correlate with longer term changes (more than 5 years) in precipitation. Ground-water pumping fromthe alluvial aquifer at well WW-5c and pumping and discharge from well RNM-2s appear to cause water-level fluctuations in nearby observation wells. The remaining known sources of water-level fluctuations do not appear to substantially affect water-level changes (seismic activity and underground nuclear testing) or do not affect changes over a period of more than 1 year (barometric pressure and Earth tides) in wells in the Frenchman Flat area.

  12. Incorporating geologic information into hydraulic tomography: A general framework based on geostatistical approach

    NASA Astrophysics Data System (ADS)

    Zha, Yuanyuan; Yeh, Tian-Chyi J.; Illman, Walter A.; Onoe, Hironori; Mok, Chin Man W.; Wen, Jet-Chau; Huang, Shao-Yang; Wang, Wenke

    2017-04-01

    Hydraulic tomography (HT) has become a mature aquifer test technology over the last two decades. It collects nonredundant information of aquifer heterogeneity by sequentially stressing the aquifer at different wells and collecting aquifer responses at other wells during each stress. The collected information is then interpreted by inverse models. Among these models, the geostatistical approaches, built upon the Bayesian framework, first conceptualize hydraulic properties to be estimated as random fields, which are characterized by means and covariance functions. They then use the spatial statistics as prior information with the aquifer response data to estimate the spatial distribution of the hydraulic properties at a site. Since the spatial statistics describe the generic spatial structures of the geologic media at the site rather than site-specific ones (e.g., known spatial distributions of facies, faults, or paleochannels), the estimates are often not optimal. To improve the estimates, we introduce a general statistical framework, which allows the inclusion of site-specific spatial patterns of geologic features. Subsequently, we test this approach with synthetic numerical experiments. Results show that this approach, using conditional mean and covariance that reflect site-specific large-scale geologic features, indeed improves the HT estimates. Afterward, this approach is applied to HT surveys at a kilometer-scale-fractured granite field site with a distinct fault zone. We find that by including fault information from outcrops and boreholes for HT analysis, the estimated hydraulic properties are improved. The improved estimates subsequently lead to better prediction of flow during a different pumping test at the site.

  13. Estimating hydraulic properties using a moving-model approach and multiple aquifer tests

    USGS Publications Warehouse

    Halford, K.J.; Yobbi, D.

    2006-01-01

    A new method was developed for characterizing geohydrologic columns that extended >600 m deep at sites with as many as six discrete aquifers. This method was applied at 12 sites within the Southwest Florida Water Management District. Sites typically were equipped with multiple production wells, one for each aquifer and one or more observation wells per aquifer. The average hydraulic properties of the aquifers and confining units within radii of 30 to >300 m were characterized at each site. Aquifers were pumped individually and water levels were monitored in stressed and adjacent aquifers during each pumping event. Drawdowns at a site were interpreted using a radial numerical model that extended from land surface to the base of the geohydrologic column and simulated all pumping events. Conceptually, the radial model moves between stress periods and recenters on the production well during each test. Hydraulic conductivity was assumed homogeneous and isotropic within each aquifer and confining unit. Hydraulic property estimates for all of the aquifers and confining units were consistent and reasonable because results from multiple aquifers and pumping events were analyzed simultaneously. Copyright ?? 2005 National Ground Water Association.

  14. Estimating hydraulic properties using a moving-model approach and multiple aquifer tests.

    PubMed

    Halford, Keith J; Yobbi, Dann

    2006-01-01

    A new method was developed for characterizing geohydrologic columns that extended >600 m deep at sites with as many as six discrete aquifers. This method was applied at 12 sites within the Southwest Florida Water Management District. Sites typically were equipped with multiple production wells, one for each aquifer and one or more observation wells per aquifer. The average hydraulic properties of the aquifers and confining units within radii of 30 to >300 m were characterized at each site. Aquifers were pumped individually and water levels were monitored in stressed and adjacent aquifers during each pumping event. Drawdowns at a site were interpreted using a radial numerical model that extended from land surface to the base of the geohydrologic column and simulated all pumping events. Conceptually, the radial model moves between stress periods and recenters on the production well during each test. Hydraulic conductivity was assumed homogeneous and isotropic within each aquifer and confining unit. Hydraulic property estimates for all of the aquifers and confining units were consistent and reasonable because results from multiple aquifers and pumping events were analyzed simultaneously.

  15. Screening Models of Aquifer Heterogeneity Using the Flow Dimension

    NASA Astrophysics Data System (ADS)

    Walker, D. D.; Cello, P. A.; Roberts, R. M.; Valocchi, A. J.

    2007-12-01

    Despite advances in test interpretation and modeling, typical groundwater modeling studies only indirectly use the parameters and information inferred from hydraulic tests. In particular, the Generalized Radial Flow approach to test interpretation infers the flow dimension, a parameter describing the geometry of the flow field during a hydraulic test. Noninteger values of the flow dimension often are inferred for tests in highly heterogeneous aquifers, yet subsequent modeling studies typically ignore the flow dimension. Monte Carlo analyses of detailed numerical models of aquifer tests examine the flow dimension for several stochastic models of heterogeneous transmissivity, T(x). These include multivariate lognormal, fractional Brownian motion, a site percolation network, and discrete linear features with lengths distributed as power-law. The behavior of the simulated flow dimensions are compared to the flow dimensions observed for multiple aquifer tests in a fractured dolomite aquifer in the Great Lakes region of North America. The combination of multiple hydraulic tests, observed fracture patterns, and the Monte Carlo results are used to screen models of heterogeneity and their parameters for subsequent groundwater flow modeling.

  16. Comparison of denitrification activity measurements in groundwater using cores and natural-gradient tracer tests

    USGS Publications Warehouse

    Smith, R.L.; Garabedian, S.P.; Brooks, M.H.

    1996-01-01

    The transport of many solutes in groundwater is dependent upon the relative rates of physical flow and microbial metabolism. Quantifying rates of microbial processes under subsurface conditions is difficult and is most commonly approximated using laboratory studies with aquifer materials. In this study, we measured in situ rates of denitrification in a nitrate- contaminated aquifer using small-scale, natural-gradient tracer tests and compared the results with rates obtained from laboratory incubations with aquifer core material. Activity was measured using the acetylene block technique. For the tracer tests, co-injection of acetylene and bromide into the aquifer produced a 30 ??M increase in nitrous oxide after 10 m of transport (23-30 days). An advection-dispersion transport model was modified to include an acetylene-dependent nitrous oxide production term and used to simulate the tracer breakthrough curves. The model required a 4-day lag period and a relatively low sensitivity to acetylene to match the narrow nitrous oxide breakthrough curves. Estimates of in situ denitrification rates were 0.60 and 1.51 nmol of N2O produced cm-3 aquifer day-1 for two successive tests. Aquifer core material collected from the tracer test site and incubated as mixed slurries in flasks and as intact cores yielded rates that were 1.2-26 times higher than the tracer test rate estimates. Results with the coring-dependent techniques were variable and subject to the small- scale heterogeneity within the aquifer, while the tracer tests integrated the heterogeneity along a flow path, giving a rate estimate that is more applicable to transport at the scale of the aquifer.

  17. Analysis of reinjection problems at the Stony Brook ATES field test site

    NASA Astrophysics Data System (ADS)

    Supkow, D. J.; Shultz, J. A.

    1982-12-01

    Aquifer Thermal Energy Storage (ATES) is one of several energy storage technologies being investigated by the DOE to determine the feasibility of reducing energy consumption by means of energy management systems. The State University of New York, (SUNY) Stony Brook, Long Island, New York site was selected by Battelle PNL for a Phase 1 investigation to determine the feasibility of an ATES demonstration to seasonally store chill energy by injecting chilled water in the winter and recovering it at a maximum rate of 100 MBTU/hr (30 MW) in the summer. The Phase 1 study was performed during 1981 by Dames & Moore under subcontract to Batelle PLN. The pumping and injection tests were performed using two wells in a doublet configuration. Well PI-1 is a previously existing well and PI-2 was installed specifically for this investigation. Both wells are screened in the Upper Magothy aquifer from approximately 300 to 350 feet below ground surface. Nine observation wells were also installed as a portion of the investigation to monitor water level and aquifer temperature changes during the test.

  18. Development of a method for in situ measurement of denitrification in aquifers using 15N tracer tests and membrane inlet mass spectrometry

    NASA Astrophysics Data System (ADS)

    Eschenbach, W.; Well, R.; Flessa, H.; Walther, W.; Duijnisveld, W. H. M.

    2009-04-01

    In NO3- contaminated aquifers containing reduced compounds like organic carbon or sulfides, denitrification is an intense process. Its characterization is of interest because NO3- consump-tion improves water quality and N2O production can cause emission of this greenhouse gas to the atmosphere. Spatial distribution of NO3- and N2 produced by denitrification in groundwa-ter (excess N2) reflects the NO3- input as well as cumulative denitrification during aquifer pas-sage. Reaction progress (RP) at a given location, i.e. the relative consumption by denitrifica-tion of the NO3- that had been leached to the aquifers, characterizes the stage of the denitrifi-cation process. RP can be derived from the ratio between accumulated gaseous denitrification products and initial NO3- concentrations. The amount and spatial distribution of reduced com-pounds within denitrifying aquifers is not well known. Recent findings from parallel investi-gations on in situ denitrification and reactive compounds suggests that single-well 15N tracer tests might be suitable to characterize the stock of reduced compounds in aquifers (Konrad 2007). The overall objective of our studies is measure the spatial dynamics of denitrification within two sandy aquifers in northern Germany. This includes measurement of the actually occurring denitrification process. Moreover we want to determine the long-term denitrification potential which is governed by the stock of reactive material. Here we present a new approach for in situ-measurement of denitrification at monitoring wells using a combination of 15N-tracer push-pull experiments with in situ analysis of 15N-labled N2 and N2O using membrane inlet mass spectrometry (MIMS). We will present first results from a laboratory test with aquifer mesocosms using the MIMS method. In this test we supplemented aquifer material of two depths (2 and 7 m below surface) of a drinking water catchment in Northwest Germany with K15NO3 solution. After tracer application we took wa-ter samples at regular intervals with an automated sampling device over 5 days. A small part of the sample was directly conducted in the membrane inlet of our mass spectrometer and the other part was collected in serum bottles which were immediately sealed with rubber septa and stored for later measurement by isotope ratio mass spectrometer (IRMS). Results available up to now showed for both types of measurement a linear increase of deni-trification products (15(N2O+N2)) over time. At the end of our laboratory test we measured up to 270 and 2400 µg/L 15(N2O+N2) in the water samples from the supplemented aquifer mate-rial of 3 and 7 m depth respectively. Because of the online measurement with MIMS we were able to see during the experiment if and when the production of the labeled denitrification products started. Later-on this approach will be used in the field. Here, the MIMS-technique will be especially advantageous, because the success of tracer test can be immediately seen during in situ sampling. Results of excess-N2 measurements at the monitoring wells within the two aquifers showed a range of 0 to 30 mg L-1 excess-N2 and a RP between 0 and 100%. References: Konrad, C. (2007): Methoden zur Bestimmung des Umsatzes von Stickstoff, dargestellt für drei Pleistozäne Grundwasserleiter Norddeutschlands, PhD thesis, Dresden Univ. of Techn., Germany, 157 pp.

  19. Application of a nonlinear slug test model

    USGS Publications Warehouse

    McElwee, C.D.

    2001-01-01

    Knowledge of the hydraulic conductivity distribution is of utmost importance in understanding the dynamics of an aquifer and in planning the consequences of any action taken upon that aquifer. Slug tests have been used extensively to measure hydraulic conductivity in the last 50 years since Hvorslev's (1951) work. A general nonlinear model based on the Navier-Stokes equation, nonlinear frictional loss, non-Darcian flow, acceleration effects, radius changes in the wellbore, and a Hvorslev model for the aquifer has been implemented in this work. The nonlinear model has three parameters: ??, which is related primarily to radius changes in the water column; A, which is related to the nonlinear head losses; and K, the hydraulic conductivity. An additional parameter has been added representing the initial velocity of the water column at slug initiation and is incorporated into an analytical solution to generate the first time step before a sequential numerical solution generates the remainder of the time solution. Corrections are made to the model output for acceleration before it is compared to the experimental data. Sensitivity analysis and least squares fitting are used to estimate the aquifer parameters and produce some diagnostic results, which indicate the accuracy of the fit. Finally, an example of field data has been presented to illustrate the application of the model to data sets that exhibit nonlinear behavior. Multiple slug tests should be taken at a given location to test for nonlinear effects and to determine repeatability.

  20. Saline aquifer mapping project in the southeastern United States

    USGS Publications Warehouse

    Williams, Lester J.; Spechler, Rick M.

    2011-01-01

    In 2009, the U.S. Geological Survey initiated a study of saline aquifers in the southeastern United States to evaluate the potential use of brackish or saline water from the deeper portions of the Floridan aquifer system and the underlying Coastal Plain aquifer system (Fig. 1). The objective of this study is to improve the overall understanding of the available saline water resources for potential future development. Specific tasks are to (1) develop a digital georeferenced database of borehole geophysical data to enable analysis and characterization of saline aquifers (see locations in Fig. 1), (2) identify and map the regional extent of saline aquifer systems and describe the thickness and character of hydrologic units that compose these systems, and (3) delineate salinity variations at key well sites and along section lines to provide a regional depiction of the freshwater-saltwater interfaces. Electrical resistivity and induction logs, coupled with a variety of different porosity logs (sonic, density, and neutron), are the primary types of borehole geophysical logs being used to estimate the water quality in brackish and saline formations. The results from the geophysical log calculations are being compared to available water-quality data obtained from water wells and from drill-stem water samples collected in test wells. Overall, the saline aquifer mapping project is helping to improve the understanding of saline water resources in the area. These aquifers may be sources of large quantities of water that could be treated by using reverse osmosis or similar technologies, or they could be used for aquifer storage and recovery systems.

  1. Numerical groundwater-flow modeling to evaluate potential effects of pumping and recharge: implications for sustainable groundwater management in the Mahanadi delta region, India

    NASA Astrophysics Data System (ADS)

    Sahoo, Sasmita; Jha, Madan K.

    2017-12-01

    Process-based groundwater models are useful to understand complex aquifer systems and make predictions about their response to hydrological changes. A conceptual model for evaluating responses to environmental changes is presented, considering the hydrogeologic framework, flow processes, aquifer hydraulic properties, boundary conditions, and sources and sinks of the groundwater system. Based on this conceptual model, a quasi-three-dimensional transient groundwater flow model was designed using MODFLOW to simulate the groundwater system of Mahanadi River delta, eastern India. The model was constructed in the context of an upper unconfined aquifer and lower confined aquifer, separated by an aquitard. Hydraulic heads of 13 shallow wells and 11 deep wells were used to calibrate transient groundwater conditions during 1997-2006, followed by validation (2007-2011). The aquifer and aquitard hydraulic properties were obtained by pumping tests and were calibrated along with the rainfall recharge. The statistical and graphical performance indicators suggested a reasonably good simulation of groundwater flow over the study area. Sensitivity analysis revealed that groundwater level is most sensitive to the hydraulic conductivities of both the aquifers, followed by vertical hydraulic conductivity of the confining layer. The calibrated model was then employed to explore groundwater-flow dynamics in response to changes in pumping and recharge conditions. The simulation results indicate that pumping has a substantial effect on the confined aquifer flow regime as compared to the unconfined aquifer. The results and insights from this study have important implications for other regional groundwater modeling studies, especially in multi-layered aquifer systems.

  2. Influence of the heterogeneity on the hydraulic conductivity of a real aquifer

    NASA Astrophysics Data System (ADS)

    Carmine, Fallico; Aldo Pedro, Ferrante; Chiara, Vita Maria; Bartolo Samuele, De

    2010-05-01

    Many factors influence the flux in the porous media therefore the values of the representative parameters of the aquifer such as the hydraulic conductivity (k). A lot of studies have shown that this parameter increases with the portion of the aquifer tested. The main cause of this behaviour is the heterogeneity in the aquifer (Sànchez-Vila et al., 1996). It was also verified that the scale dependence of hydraulic conductivity does not depend on the specific method of measurement (Schulze-Makuch and Cherkauer, 1998). An experimental approach to study this phenomenon is based on sets of measurements carried out at different scales. However, one should consider that for the lower scale values k can be determined by direct measurements, performed in the laboratory using samples of different dimensions; whyle, for the large scales the measurement of the hydraulic conductivity requires indirect methods (Johnson and Sen, 1988; Katz and Thompson, 1986; Bernabé and Revil, 1995). In this study the confined aquifer of Montalto Uffugo test field was examined. This aquifer has the geological characteristics of a recently formed valley, with conglomeratic and sandy alluvial deposits; specifically the layer of sands and conglomerates, with a significant percentage of silt at various levels, lies about 55-60 m below the ground surface, where there is a heavy clay formation. Moreover in the test field, for the considered confined aquifer, there are one completely penetrating well, five partially penetrating wells and two completely penetrating piezometers. Along two vertical lines a series of cylindrical samples (6.4 cm of diameter and 15 cm of head) were extracted and for each one of them the k value was measured in laboratory by direct methods, based on the use of flux cells. Also indirect methods were used; in fact, a series of slug tests was carried out, determining the corresponding k values and the radius of influence (R). Moreover another series of pumping tests was carried out determining again the corresponding k values and the radius of influence; in fact, changing the pumping rate, varies also R. For the different sets of k values, obtained by different measurement methods, a statistical analysis was performed, determining the meaningful statistical parameters. All the obtained k values were examined, furnishing a scaling law of k for the considered aquifer. The equation describing this experimental trend is a power law, according to Schulze-Makuch and Cherkauer (1998). These results, obtained for the Montalto Uffugo test field, show that the hydraulic conductivity grows with the radius of influence, id est with the volume of the aquifer involved in the measurement. Moreover, the threshold value, to which k tends with the growing of R, was determined. References Bernabé, Y. and Revil, A. 1995. Pore-scale heterogeneity, energy dissipation and the transport properties of rocks. Geophys. Res. Lett. 22: 1529-1532. Johnson, D.L. and Sen, P.N. 1988. Dependence of the conductivity of a porous medium on electrolytic conductivity. Phys. Rev. B Condens. matter. 37: 3502-3510. Katz, A.J. and Thompson, A.H. 1986. Quantitative prediction of permeability in porous rock. Phys. Rev. B Condens. Matter. 34: 8179-8181. Sanchez-Villa X, Carrera J, Girardi JP (1996). Scale effects in transmissivity. J Hydrol 183:1-22. Schulze-Makuch D, Cherkauer DS (1998). Variations in hydraulic conductivity with scale of measurement during aquifer tests in heterogeneous, porous, carbonate rocks. Hydrogeol J. 6:204-215.

  3. Spatio-temporal analysis of recent groundwater-level trends in the Red River Delta, Vietnam

    NASA Astrophysics Data System (ADS)

    Bui, Duong Du; Kawamura, Akira; Tong, Thanh Ngoc; Amaguchi, Hideo; Nakagawa, Naoko

    2012-12-01

    A groundwater-monitoring network has been in operation in the Red River Delta, Vietnam, since 1995. Trends in groundwater level (1995-2009) in 57 wells in the Holocene unconfined aquifer and 63 wells in the Pleistocene confined aquifer were determined by applying the non-parametric Mann-Kendall trend test and Sen's slope estimator. At each well, 17 time series (e.g. annual, seasonal, monthly), computed from the original data, were analyzed. Analysis of the annual groundwater-level means revealed that 35 % of the wells in the unconfined aquifer showed downward trends, while about 21 % showed upward trends. On the other hand, confined-aquifer groundwater levels experienced downward trends in almost all locations. Spatial distributions of trends indicated that the strongly declining trends (>0.3 m/year) were mainly found in urban areas around Hanoi where there is intensive abstraction of groundwater. Although the trend results for most of the 17 time series at a given well were quite similar, different trend patterns were detected in several. The findings reflect unsustainable groundwater development and the importance of maintaining groundwater monitoring and a database in the Delta, particularly in urban areas.

  4. Relation between organic-wastewater compounds, groundwater geochemistry, and well characteristics for selected wells in Lansing, Michigan

    USGS Publications Warehouse

    Haack, Sheridan K.; Luukkonen, Carol L.

    2013-01-01

    In 2010, groundwater from 20 Lansing Board of Water and Light (BWL) production wells was tested for 69 organic-wastewater compounds (OWCs). The OWCs detected in one-half of the sampled wells are widely used in industrial and environmental applications and commonly occur in many wastes and stormwater. To identify factors that contribute to the occurrence of these constituents in BWL wells, the U.S. Geological Survey (USGS) interpreted the results of these analyses and related detections of OWCs to local characteristics and groundwater geochemistry. Analysis of groundwater-chemistry data collected by the BWL during routine monitoring from 1969 to 2011 indicates that the geochemistry of the BWL wells has changed over time, with the major difference being an increase in sodium and chloride. The concentrations of sodium and chloride were positively correlated to frequency of OWC detections. The BWL wells studied are all completed in the Saginaw aquifer, which consists of water-bearing sandstones of Pennsylvanian age. The Saginaw aquifer is underlain by the Parma-Bayport aquifer, and overlain by the Glacial aquifer. Two possible sources of sodium and chloride were evaluated: basin brines by way of the Parma-Bayport aquifer, and surficial sources by way of the Glacial aquifer. To determine if water from the underlying aquifer had influenced well-water geochemistry over time, the total dissolved solids concentration and changes in major ion concentrations were examined with respect to well depth, age, and pumping rate. To address a possible surficial source of sodium and chloride, 25 well, aquifer, or hydrologic characteristics, and 2 groundwater geochemistry variables that might influence whether, or the rate at which, water from the land surface could reach each well were compared to OWC detections and well chemistry. The statistical tests performed during this study, using available variables, indicated that reduced time of travel of water from the land surface to the well opening was significantly correlated with detections of OWCs. No specific well or aquifer characteristic was correlated with OWC detections; however, wells with detections tended to have less modeled confining material thickness (as simulated in the regional groundwater flow model), which is an estimate of the amount of clay or shale between the Glacial and Saginaw aquifers. Additional analyses and collection of other data would be required to more conclusively identify the source and to determine the potential vulnerability of other wells because each BWL well may have a somewhat unique set of characteristics that governs its response to pumping. Therefore, it is possible that a relevant explanatory variable was not included in this analysis. The current patterns of geochemistry, and the relation between these patterns and volume of pumpage for the BWL wells, indicates other wells may be susceptible to OWCs in the future.

  5. Conceptualization of the predevelopment groundwater flow system and transient water-level responses in Yucca Flat, Nevada National Security Site, Nevada

    USGS Publications Warehouse

    Fenelon, Joseph M.; Sweetkind, Donald S.; Elliott, Peggy E.; Laczniak, Randell J.

    2012-01-01

    Contaminants introduced into the subsurface of Yucca Flat, Nevada National Security Site, by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. The potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by groundwater transport. The primary hydrologic control on this transport is evaluated and examined through a set of contour maps developed to represent the hydraulic-head distribution within the two major aquifer systems underlying the area. Aquifers and confining units within these systems were identified and their extents delineated by merging and analyzing hydrostratigraphic framework models developed by other investigators from existing geologic information. Maps of the hydraulic-head distributions in the major aquifer systems were developed from a detailed evaluation and assessment of available water-level measurements. The maps, in conjunction with regional and detailed hydrogeologic cross sections, were used to conceptualize flow within and between aquifer systems. Aquifers and confining units are mapped and discussed in general terms as being one of two aquifer systems: alluvial-volcanic or carbonate. The carbonate aquifers are subdivided and mapped as independent regional and local aquifers, based on the continuity of their component rock. Groundwater flow directions, approximated from potentiometric contours, are indicated on the maps and sections and discussed for the alluvial-volcanic and regional carbonate aquifers. Flow in the alluvial-volcanic aquifer generally is constrained by the bounding volcanic confining unit, whereas flow in the regional carbonate aquifer is constrained by the siliceous confining unit. Hydraulic heads in the alluvial-volcanic aquifer typically range from 2,400 to 2,530 feet and commonly are elevated about 20-100 feet above heads in the underlying regional carbonate aquifer. Flow directions in the alluvial-volcanic aquifer are variable and are controlled by localized areas where small amounts of water can drain into the regional carbonate aquifer. These areas commonly are controlled by geologic structures, such as Yucca fault. Flow in the regional carbonate aquifer generally drains to the center of the basin; from there flow is to the south-southeast out of the study area toward downgradient discharge areas. Southward flow in the regional carbonate aquifer occurs in a prominent potentiometric trough that results from a faulted zone of enhanced permeability centered about Yucca fault. Vertical hydraulic gradients between the aquifer systems are downward throughout the study area; however, flow from the alluvial-volcanic aquifer into the underlying carbonate aquifer is believed to be minor because of the intervening confining unit. Transient water levels were identified and analyzed to understand hydraulic responses to stresses in Yucca Flat. Transient responses have only a minimal influence on the general predevelopment flow directions in the aquifers. The two primary anthropogenic stresses on the groundwater system since about 1950 are nuclear testing and pumping. Most of the potentiometric response in the aquifers to pumping or past nuclear testing is interim and localized. Persistent, long-lasting changes in hydraulic head caused by nuclear testing occur only in confining units where groundwater fluxes are negligible. A third stress on the groundwater system is natural recharge, which can cause minor, short- and long-term changes in water levels. Long-term hydrographs affected by natural recharge, grouped by similar trend, cluster in distinct areas of Yucca Flat and are controlled primarily by spatial differences in local recharge patterns.

  6. Geohydrology of the Vamoosa-Ada aquifer east-central Oklahoma with a section on chemical quality of water

    USGS Publications Warehouse

    D'Lugosz, Joseph J.; McClaflin, Roger G.; Marcher, Melvin V.

    1986-01-01

    The Vamoosa-Ada aquifer, which underlies an area of about 2,320 mi2, consists principally of the Vamoosa Formation and the overlying Ada Group of Pennsylvanian age. Rocks comprising the aquifer were deposited in a nearshore environment ranging from marine on the west to nonmarine on the east. Because of changes in depositional environments with time and from place to place, the aquifer is a complex sequence of fine- to very fine-grained sandstone, siltstone, shale, and conglomerate, with interbedded very thin limestone. The aggregate thickness of water-bearing sandstones is greatest south of the Cimarron River, where it reaches a maximum of 550 ft in the vicinity of Seminole. North of the Cimarron River, the average aggregate thickness of the sandstones is about 100 ft, but locally it may be as much as 200 ft. Transmissivity values derived from seven aquifer tests made for this study range from 70 to 490 ft2 per day; values decrease from south to north with decreasing sandstone thickness. Hydraulic-conductivity values range from 2 to 4 ft per day. Storage coefficients for the confined part of the aquifer, as determined from four aquifer tests made during 1944, have an average value of 0.0002. The average storage coefficient for the unconfined part of the aquifer is estimated at 0.12, based on an analysis of geophysical logs and grain-size data. The specific capacity of wells tested is generally less than 1 gallon per minute per foot of drawdown. An approximate hydrologic budget for the aquifer for 1975 gives values, in acre-feet per year, of 93,000 for recharge, 233,000 for runoff, and 2,003,000 for evapotranspiration. The total of these values is almost equal to the average annual precipitation of 2,330,000 acre-ft per year. The estimated amount of water containing a maximum of 1,500 milligrams per liter of dissolved solids stored in the aquifer is estimated at 60 million acre-ft. Of this amount, an estimated 36 million acre-ft is available for use. The quality of water in the Vamoosa-Ada aquifer generally is suitable for municipal, domestic, and stock use. Of 55 water samples analyzed in the laboratory, about 75 percent were of the sodium bicarbonate or sodium calcium bicarbonate type; the remainder were of the sodium sulfate, calcium sulfate, sodium chloride, or indeterminate types. Laboratory and on-site chemical-quality data indicate that mineralization of both ground and surface waters is greater than normal in some areas. Water samples from 7 wells and 12 stream sites had concentrations of bromide exceeding 1 milligram per liter; the only known source of bromide in the area is brine associated with petroleum production.

  7. Response to Comment by H. Lough, Department of Civil Engineering, University of Canterbury, Christchurch, New Zealand, on the Paper " Stream Depletion Predictions using Pumping Test Data from A Heterogeneous Stream-Aquifer System (A Case Study from the Gr

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kollet, S J; Zlotnik, V A

    2004-12-20

    We thank H. Lough for her interest in our data set and the attempt to re-analyze our results (Kollet and Zlotnik, 2003) using the recent model by Hunt (2003). We welcome others to share our unique data set of the pumping test from the Prairie Creek site, Nebraska, USA. Nevertheless we believe that this particular attempt failed, because H. Lough selected a wrong model of semi-confined aquifer conditions for the interpretation of the pumping test data, which was collected in an unconfined aquifer. H. Lough based her selection on the three distinct drawdown segments observed during the test. It ismore » well known that geologically distinct aquifers can yield a three-segment drawdown response under pumping conditions (e.g., Streltsova, 1988). Examples include unconfined aquifers (e.g., Neuman, 1972; Moench, 1997), aquifers with double porosity or fractures (e.g., Barenblatt et al., 1960; Boulton and Streltsova-Adams, 1978), and (semi-) confined aquifers in contact with aquitards (e.g. Cooley and Case, 1973; Moench, 1985). At the Prairie Creek site the aquifer is unconfined. The interpretation of the pumping test data collected at the site using type curves that are valid for an aquifer-aquitard system is a mistake. In fact, this approach illustrates a typical problem associated with inverse modeling: drastically different models can closely reproduce a system response and yield some parameter estimates, although the models do not represent the real system adequately. Here, the improper model yields some parameter estimates for an aquitard, although the aquitard does not exist at the Prairie Creek test site. We must also unequivocally state that the model by Hunt (2003) is clearly formulated and correct for stream-aquifer-aquitard systems within the stated limitations (pumping wells screened only in the lowest stratigraphic layer, etc.). However, the Hunt (1999) or BZT (Butler et al., 2001) models should be used for interpreting pumping tests near streams in non-leaky aquifers as outlined in our study (Kollet and Zlotnik, 2003). The purpose of the comment by H. Lough is to examine three drawdown segments and results from Kollet and Zlotnik (2003) using a newer analytical model of stream-aquifer interactions by Hunt (2003). We will address the key issues of this comment in this paper.« less

  8. Analysis of an unconfined aquifer subject to asynchronous dual-tide propagation

    USGS Publications Warehouse

    Rotzoll, K.; El-Kadi, A. I.; Gingerich, S.B.

    2008-01-01

    Most published solutions for aquifer responses to ocean tides focus on the one-sided attenuation of the signal as it propagates inland. However, island aquifers experience periodic forcing from the entire coast, which can lead to integrated effects of different tidal signals, especially on narrow high-permeability islands. In general, studies disregard a potential time lag as the tidal wave sweeps around the island. We present a one-dimensional analytical solution to the ground water flow equation subject to asynchronous and asymmetric oscillating head conditions on opposite boundaries and test it on data from an unconfined volcanic aquifer in Maui. The solution considers sediment-damping effects at the coastline. The response of Maui Aquifers indicate that water table elevations near the center of the aquifer are influenced by a combination of tides from opposite coasts. A better match between the observed ground water head and the theoretical response can be obtained with the proposed dual-tide solution than with single-sided solutions. Hydraulic diffusivity was estimated to be 2.3 ?? 107 m 2/d. This translates into a hydraulic conductivity of 500 m/d, assuming a specific yield of 0.04 and an aquifer thickness of 1.8 km. A numerical experiment confirmed the hydraulic diffusivity value and showed that the y-intercepts of the modal attenuation and phase differences estimated by regression can approximate damping factors caused by low-permeability units at the boundary.

  9. Integration of models of various types of aquifers for water quality management in the transboundary area of the Soča/Isonzo river basin (Slovenia/Italy).

    PubMed

    Vižintin, Goran; Ravbar, Nataša; Janež, Jože; Koren, Eva; Janež, Naško; Zini, Luca; Treu, Francesco; Petrič, Metka

    2018-04-01

    Due to intrinsic characteristics of aquifers groundwater frequently passes between various types of aquifers without hindrance. The complex connection of underground water paths enables flow regardless of administrative boundaries. This can cause problems in water resources management. Numerical modelling is an important tool for the understanding, interpretation and management of aquifers. Useful and reliable methods of numerical modelling differ with regard to the type of aquifer, but their connections in a single hydrodynamic model are rare. The purpose of this study was to connect different models into an integrated system that enables determination of water travel time from the point of contamination to water sources. The worst-case scenario is considered. The system was applied in the Soča/Isonzo basin, a transboundary river in Slovenia and Italy, where there is a complex contact of karst and intergranular aquifers and surface flows over bedrock with low permeability. Time cell models were first elaborated separately for individual hydrogeological units. These were the result of numerical hydrological modelling (intergranular aquifer and surface flow) or complex GIS analysis taking into account the vulnerability map and tracer tests results (karst aquifer). The obtained cellular models present the basis of a contamination early-warning system, since it allows an estimation when contaminants can be expected to appear, and in which water sources. The system proves that the contaminants spread rapidly through karst aquifers and via surface flows, and more slowly through intergranular aquifers. For this reason, karst water sources are more at risk from one-off contamination incidents, while water sources in intergranular aquifers are more at risk in cases of long-term contamination. The system that has been developed is the basis for a single system of protection, action and quality monitoring in the areas of complex aquifer systems within or on the borders of administrative units. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Proposed artificial recharge studies in northern Qatar

    USGS Publications Warehouse

    Kimrey, J.O.

    1985-01-01

    The aquifer system in northern Qatar comprises a water-table aquifer in the Rus Formation which is separated by an aquitard from a partially confined aquifer in the top of the overlying Umm er Radhuma Formation. These two aquifers are composed of limestone and dolomite of Eocene and Paleocene age and contain a fragile lens of freshwater which is heavily exploited as a source of water for agricultural irrigation. Net withdrawals are greatly in excess of total recharge, and quality of ground water is declining. Use of desalinated seawater for artificial recharge has been proposed for the area. Artificial recharge, on a large scale, could stabilize the decline in ground-water quality while allowing increased withdrawals for irrigation. The proposal appears technically feasible. Recharge should be by injection to the Umm er Radhuma aquifer whose average transmissivity is about 2,000 meters squared per day (as compared to an average of about 200 meters squared per day for the Rus aquifer). Implementation of artificial recharge should be preceded by a hydrogeologic appraisal. These studies should include test drilling, conventional aquifer tests, and recharge-recovery tests at four sites in northern Qatar. (USGS)

  11. Electrical-analog-model study of water resources of the Columbus area, Bartholomew County, Indiana

    USGS Publications Warehouse

    Watkins, Frank A.; Heisel, J.E.

    1970-01-01

    The Columbus study area is in part of a glacial outwash sand and gravel aquifer that was deposited in a preglacial bedrock valley. The study area extends from the north line of Bartholomew County to the south county line and includes a small part of Jackson County south of Sand Creek and east of the East Fork White River. This report area includes about 100 square miles of the aquifer. In the Columbus area, ground water in the outwash aquifer is unconfined. Results of pumping tests and estimates derived from specific-capacity data indicate that the average horizontal permeability for this aquifer is about 3,500 gallons per day per square foot. An average coefficient of storage of about 0.2 was determined from pumping tests. Transmissibilities range from near zero in some places along the boundary to about 500,000 gallons per day per foot in the thicker parts of the aquifer. About 800,000 acre-feet of water is in storage in the aquifer. This storage is equivalent to an average yield of 34 million gallons per day for about 21 years without recharge. An electrical-analog model was built to analyze the aquifer system and determine the effects of development. Analysis of the model indicates that there is more than enough water to meet the estimated needs of the city of Columbus without seriously depleting the aquifer. Additional withdrawals will affect the flow in the Flatrock River, but if the withdrawals are made south of the city, they will not affect the river any more than present pumping. Future pumping should be confined to the deepest part of the outwash aquifer and (or) to the area adjacent to the streams. On the basis of an hypothesized amount and distribution of pumping, the decline in water levels in the Columbus area as predicted by the model for the period 1970-2015 ranged from about 20 feet in the center of the areas of pumping to 3 feet or less in the areas upstream and downstream from these areas of pumping.

  12. Using predictive uncertainty analysis to optimise tracer test design and data acquisition

    NASA Astrophysics Data System (ADS)

    Wallis, Ilka; Moore, Catherine; Post, Vincent; Wolf, Leif; Martens, Evelien; Prommer, Henning

    2014-07-01

    Tracer injection tests are regularly-used tools to identify and characterise flow and transport mechanisms in aquifers. Examples of practical applications are manifold and include, among others, managed aquifer recharge schemes, aquifer thermal energy storage systems and, increasingly important, the disposal of produced water from oil and shale gas wells. The hydrogeological and geochemical data collected during the injection tests are often employed to assess the potential impacts of injection on receptors such as drinking water wells and regularly serve as a basis for the development of conceptual and numerical models that underpin the prediction of potential impacts. As all field tracer injection tests impose substantial logistical and financial efforts, it is crucial to develop a solid a-priori understanding of the value of the various monitoring data to select monitoring strategies which provide the greatest return on investment. In this study, we demonstrate the ability of linear predictive uncertainty analysis (i.e. “data worth analysis”) to quantify the usefulness of different tracer types (bromide, temperature, methane and chloride as examples) and head measurements in the context of a field-scale aquifer injection trial of coal seam gas (CSG) co-produced water. Data worth was evaluated in terms of tracer type, in terms of tracer test design (e.g., injection rate, duration of test and the applied measurement frequency) and monitoring disposition to increase the reliability of injection impact assessments. This was followed by an uncertainty targeted Pareto analysis, which allowed the interdependencies of cost and predictive reliability for alternative monitoring campaigns to be compared directly. For the evaluated injection test, the data worth analysis assessed bromide as superior to head data and all other tracers during early sampling times. However, with time, chloride became a more suitable tracer to constrain simulations of physical transport processes, followed by methane. Temperature data was assessed as the least informative of the solute tracers. However, taking costs of data acquisition into account, it could be shown that temperature data when used in conjunction with other tracers was a valuable and cost-effective marker species due to temperatures low cost to worth ratio. In contrast, the high costs of acquisition of methane data compared to its muted worth, highlighted methanes unfavourable return on investment. Areas of optimal monitoring bore position as well as optimal numbers of bores for the investigated injection site were also established. The proposed tracer test optimisation is done through the application of common use groundwater flow and transport models in conjunction with publicly available tools for predictive uncertainty analysis to provide modelers and practitioners with a powerful yet efficient and cost effective tool which is generally applicable and easily transferrable from the present study to many applications beyond the case study of injection of treated CSG produced water.

  13. Tabulated Transmissivity and Storage Properties of the Floridan Aquifer System in Florida and Parts of Georgia, South Carolina, and Alabama

    USGS Publications Warehouse

    Kuniansky, Eve L.; Bellino, Jason C.

    2012-04-19

    A goal of the U.S. Geological Survey Groundwater Resources Program is to assess the availability of fresh water within each of the principal aquifers in the United States with the greatest groundwater withdrawals. The Floridan aquifer system (FAS), which covers an area of approximately 100,000 square miles in Florida and parts of Georgia, Alabama, Mississippi, and South Carolina, is one such principal aquifer, having the fifth largest groundwater withdrawals in the Nation, totaling 3.64 billion gallons per day in 2000. Compilation of FAS hydraulic properties is critical to the development and calibration of groundwater flow models that can be used to develop water budgets spatially and temporally, as well as to evaluate resource changes over time. Wells with aquifer test data were identified as Upper Floridan aquifer (UFA), Lower Floridan aquifer (LFA), Floridan aquifer system (FAS, Upper Floridan with some middle and/or Lower Floridan), or middle Floridan confining unit (MCU), based on the identification from the original database or report description, or comparison of the open interval of the well with previously published maps.This report consolidates aquifer hydraulic property data obtained from multiple databases and reports of the U.S. Geological Survey, various State agencies, and the Water Management Districts of Florida, that are compiled into tables to provide a single information source for transmissivity and storage properties of the FAS as of October 2011. Transmissivity calculated from aquifer pumping tests and specific-capacity data are included. Values for transmissivity and storage coefficients are intended for use in regional or sub regional groundwater flow models; thus, any tests (aquifer pumping tests and specific capacity data) that were conducted with packers or for open intervals less than 30 feet in length are excluded from the summary statistics and tables of this report, but are included in the database.The transmissivity distribution from the aquifer pumping tests is highly variable. The transmissivity based on aquifer pumping tests (from 1,045 values for the UFA and FAS) ranges from 8 to about 9,300,000 square feet per day (ft2/d) and values of storage coefficient (646 reported) range from 3x10-9 to 0.41. The 64 transmissivity values for the LFA range from about 130 to 4,500,000 ft2/d, and the 17 storage coefficient values range from 7x10-8 to 0.03. The 14 transmissivity values for the MCU range from 1 to about 600,000 ft2/d and the 10 storage coefficient values range from 8x10-8 to 0.03. Transmissivity estimates for the UFA and FAS for 442 specific capacity tests range from approximately 200 to 1,000,000 ft2/d.

  14. Analytical results of a long-term aquifer test conducted near the Rio Grande, Albuquerque, New Mexico, with a section on piezometric-extensometric test results

    USGS Publications Warehouse

    Thorn, Conde R.; Heywood, Charles E.

    2001-01-01

    The City of Albuquerque, New Mexico, is interested in gaining a better understanding, both quantitative and qualitative, of the aquifer system in and around Albuquerque. Currently (2000), the City of Albuquerque and surrounding municipalities are completely dependent on ground-water reserves for their municipal water supply. This report presents the results of a long-term aquifer test conducted near the Rio Grande in Albuquerque. The long-term aquifer test was conducted during the winter of 1994-95. The City of Albuquerque Griegos 1 water production well was pumped continuously for 54 days at an average pumping rate of 2,331 gallons per minute. During the 54-day pumping and a 30-day recovery period, water levels were recorded in a monitoring network that consisted of 3 production wells and 19 piezometers located at nine sites. These wells and piezometers were screened in river alluvium and (or) the upper and middle parts of the Santa Fe Group aquifer system. In addition to the measurement of water levels, aquifer-system compaction was monitored during the aquifer test by an extensometer. Well-bore video and flowmeter surveys were conducted in the Griegos 1 water production well at the end of the recovery period to identify the location of primary water- producing zones along the screened interval. Analytical results from the aquifer test presented in this report are based on the methods used to analyze a leaky confined aquifer system and were performed using the computer software package AQTESOLV. Estimated transmissivities for the Griegos 1 and 4 water production wells ranged from 10,570 to 24,810 feet squared per day; the storage coefficient for the Griegos 4 well was 0.0025. A transmissivity of 13,540 feet squared per day and a storage coefficient of 0.0011 were estimated from the data collected from a piezometer completed in the production interval of the Griegos 1 well.

  15. Geopressured-geothermal test of the EDNA Delcambre No. 1 well, Tigre Lagoon Field, Vermilion Parish, Louisiana: analysis of water an dissolved natural gas. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hankins, B.E.; Karkalits, O.C.

    1978-09-01

    The Edna Delcambre et al. No. 1 gas well, shut-in since June 1975, was made available for the project. Two geopressured sand-bed aquifers were tested: sand No. 3 at a depth of 12,900 feet and sand No. 1 at a depth of 12,600 feet. Each aquifer was subjected to flow tests which lasted approximately three weeks in each case. Water samples were obtained during flow testing of the two geopressured aquifers. The water contained 11.3 to 13.3% dissolved solids. Several radioactive species were measured. Radium-226 was found to be approximately 10 times more concentrated than the average amount observed inmore » surface waters. No appreciable amount of heavy metals was detected. Recombination studies at bottom-hole conditions indicate the solubility of natural gas per barrel of water to be about 24 SCF. The methane content was 93 to 95%, and the gas had a heating value in the range of 1020 to 1070 Btu/cu.ft. During the flow tests, the gas/water ratio at the well-head was observed to be 45 to 88 SCF/Bbl water produced. (MHR)« less

  16. Regeneration of a confined aquifer after redevelopment and decommission of artesian wells, example from Grafendorf aquifer (Styria, Austria)

    NASA Astrophysics Data System (ADS)

    Mehmedovski, Nudzejma; Winkler, Gerfried

    2016-04-01

    Water is essential for life and it is therefore necessary to protect drinking water sustainably. Compared to shallow groundwater, deeper groundwater is especially important due to its characteristic tendency to remain extensively unaffected by environmental impacts. Thus, the uncontrolled waste of this valuable resource has to be avoided. A lot of artesian wells have been established in Grafendorf bei Hartberg (Styria, Austria). Almost all wells were not state-of-the art. As a result the different aquifer horizons began to intermix. Additionally some of the artesian wells had a permanent free overflow and the water was not even used. Consequently, since 1950, where the mean discharge of 37 wells was 0,334 l/s per well, the discharge has decreased to 0,090 l/s until 2013, which means a decline of about 75 %. As a reaction to these declines a decommissioning campaign was conducted where 69 artesian wells have been closed by injecting a cement-bentonite suspension (ratio 3:1). The Grafendorf aquifer is situated in the Styrian Basin and consists of 5 separated artesian horizons in Neogene sediments. These artesian horizons range from 42 m (1st horizon) to 176 m (5th horizon) and mostly consist of sand, partly of fine/medium/coarse gravel and partially with minor clay content. In order to analyse the reaction of the Grafendorf aquifer to these redevelopments, 5 monitoring wells could be used for the analysis. Some monitoring wells include different aquifer horizons and hydraulically short cut them. Thus, in this work the analysis focus on the general trend of the whole aquifer system neglecting the individual interactions between the different aquifers. In a first investigation step the hydraulic properties of the aquifer system has been determined using pumping tests which were analysed with different analytical solutions with the software AQTESOLV. Overall the pumping test solutions hardly differ in the transmissivity and hydraulic conductivity. On the contrary the results for the storativity and specific storativity differ highly which was used to determine the proper analytic solution. The average transmissivity is about 9 x 10-4 m2/s and the hydraulic conductivity is about 1,5 x 10-4 m/s. The watertable trends of the 5 observed wells were analysed. The preliminary results show an increase of the watertable between 0,10 m to 0,40 m in 3 wells and even 0,1 bar (1 m) in one well. In one well a decline of 3 m can be observed since the wells have been decommissioned. However the regeneration of the aquifer has been mostly positive so far, nevertheless more studies have to be done in future to prove a long-term behaviour of the aquifer and in particular to investigate the reaction of the individual horizons and the interaction between them.

  17. Bioelectrochemical denitrification on biocathode buried in simulated aquifer saturated with nitrate-contaminated groundwater.

    PubMed

    Nguyen, Van Khanh; Park, Younghyun; Yu, Jaecheul; Lee, Taeho

    2016-08-01

    Nitrate contamination in aquifers has posed human health under high risk because people still rely on groundwater withdrawn from aquifers as drinking water and running water sources. These days, bioelectrochemical technologies have shown a great number of benefits for nitrate remediation via autotrophic denitrification in groundwater. This study tested the working possibility of a denitrifying biocathode when installed into a simulated aquifer. The reactors were filled with sand and synthetic groundwater at various ratios (10, 50, and 100 %) to clarify the effect of various biocathode states (not-buried, half-buried, and fully buried) on nitrate reduction rate and microbial communities. Decreases in specific nitrate reduction rates were found to be correlated with increases in sand/medium ratios. A specific nitrate reduction rate of 322.6 mg m(-2) day(-1) was obtained when the biocathode was fully buried in an aquifer. Microbial community analysis revealed slight differences in the microbial communities of biocathodes at various sand/medium ratios. Various coccus- and rod-shaped bacteria were found to contribute to bioelectrochemical denitrification including Thiobacillus spp. and Paracoccus spp. This study demonstrated that the denitrifying biocathode could work effectively in a saturated aquifer and confirmed the feasibility of in situ application of microbial electrochemical denitrification technology.

  18. Python-Based Applications for Hydrogeological Modeling

    NASA Astrophysics Data System (ADS)

    Khambhammettu, P.

    2013-12-01

    Python is a general-purpose, high-level programming language whose design philosophy emphasizes code readability. Add-on packages supporting fast array computation (numpy), plotting (matplotlib), scientific /mathematical Functions (scipy), have resulted in a powerful ecosystem for scientists interested in exploratory data analysis, high-performance computing and data visualization. Three examples are provided to demonstrate the applicability of the Python environment in hydrogeological applications. Python programs were used to model an aquifer test and estimate aquifer parameters at a Superfund site. The aquifer test conducted at a Groundwater Circulation Well was modeled with the Python/FORTRAN-based TTIM Analytic Element Code. The aquifer parameters were estimated with PEST such that a good match was produced between the simulated and observed drawdowns. Python scripts were written to interface with PEST and visualize the results. A convolution-based approach was used to estimate source concentration histories based on observed concentrations at receptor locations. Unit Response Functions (URFs) that relate the receptor concentrations to a unit release at the source were derived with the ATRANS code. The impact of any releases at the source could then be estimated by convolving the source release history with the URFs. Python scripts were written to compute and visualize receptor concentrations for user-specified source histories. The framework provided a simple and elegant way to test various hypotheses about the site. A Python/FORTRAN-based program TYPECURVEGRID-Py was developed to compute and visualize groundwater elevations and drawdown through time in response to a regional uniform hydraulic gradient and the influence of pumping wells using either the Theis solution for a fully-confined aquifer or the Hantush-Jacob solution for a leaky confined aquifer. The program supports an arbitrary number of wells that can operate according to arbitrary schedules. The python wrapper invokes the underlying FORTRAN layer to compute transient groundwater elevations and processes this information to create time-series and 2D plots.

  19. Inflatable straddle packers and associated equipment for hydraulic fracturing and hydrologic testing

    USGS Publications Warehouse

    Shuter, Eugene; Pemberton, Robert R.

    1978-01-01

    Independent aquifer testing is the only way to fully understand the hydrology encountered in boreholes intersecting multiple aquifers. The most feasible method to accomplish the testing of multiple aquifer wells is through the use inflatable packers. The straddle packers and associated equipment herein described arE valuable tools for making isolated aquifer tests as well as conducting hydraulic fracturing experiments. The system, due to design, permits multiple tests in a bore-hole without the necessity of tripping in and out of the hole to redress the packers prior to testing each zone. Electronic pressure transducers, the output of which was fed into strip-chart recorders, were used to monitor the zone being tested, as well as to monitor the zones above and below the packers. This was necessary to ensure that no leaking had occurred around the packers, causing hydraulic continuity between the isolated zones.

  20. Hydrostratigraphic interpretation of test-hole and geophysical data, Upper Loup River Basin, Nebraska, 2008-10

    USGS Publications Warehouse

    Hobza, Christopher M.; Asch, Theodore H.; Bedrosian, Paul A.

    2011-01-01

    Test-hole drilling has indicated greater variation in the base-of-aquifer elevation in the western part of the upper Loup study area than in the eastern part reflecting a number of deep paleovalleys incised into the Brule Formation of the White River Group. TDEM measurements within the upper Loup study area were shown to be effective as virtual boreholes in mapping out the base of the aquifer. TDEM estimates of the base of aquifer were in good accordance with existing test-hole data and were able to improve the interpreted elevation and topology of the base of the aquifer. In 2010, AMT data were collected along a profile, approximately 12 miles (19 kilometers) in length, along Whitman Road, in Grant and Cherry Counties. The AMT results along Whitman Road indicated substantial variability in the elevation of the base of the High Plains aquifer and in the distribution of highly permeable zones within the aquifer.

  1. Subsurface storage of freshwater in South Florida; a digital model analysis of recoverability

    USGS Publications Warehouse

    Merritt, Michael L.

    1985-01-01

    As part of a study of the feasibility of recovering freshwater injected and stored underground in south Florida, a digital solute-transport model was used to investigate the relation of recovery efficiency to the variety of hydrogeologic conditions that could prevail in brackish artesian aquifers and to a variety of management alternatives. The analyses employed a modeling approach in which the control for sensitivity testing was a hypothetical aquifer considered representative of permeable zones in south Florida that might be used for storage of freshwater. Parameter variations in the tests represented possible variations in aquifer conditions in the area. The applicability of the analyses to south Florida limestone aquifers required the assumption that flow nonuniformities in those aquifers are small on the scale of volumes of water likely to be injected, and that their effect could be represented as hydrodynamic dispersion. Generally, it was shown that a loss of recovery efficiency is caused by (1) processes causing mixing of injected freshwater with native saline water (hydrodynamic dispersion), (2) processes causing the more or less irreversible displacement of the injected freshwater with respect to the well (buoyancy stratification, background hydraulic gradients, and interlayer dispersion), or (3) processes causing injection and withdrawal flow patterns to be dissimilar (directionally biased well-bore plugging, and dissimilar injection and withdrawal schedules in multiple-well systems). Other results indicated that recovery efficiency improves considerably with successive cycles, providing that each recovery phase ends when the chloride concentration of withdrawn water exceeds established criteria for potability (usually 250 milligrams per liter), and that freshwater injected into highly permeable or highly saline aquifers (such as the 'boulder zone') would buoy rapidly. Many hydrologic conditions were posed for model analysis. To have obtained comparable results with operational testing would have been more costly by orders of magnitude. The tradeoff is that the validity of results obtained from computer modeling is somewhat less certain. In particular, results must be qualified with observations that (1) the complex set of processes lumped as hydrodynamic dispersion is represented with a somewhat simplified mathematical approximation, and (2) other flow processes in limestone injection zones are as yet incompletely understood. Despite such reservations, the study is considered a practical example of the use of transport models in ground-water investigations.

  2. Estimating hydraulic properties of the Floridan Aquifer System by analysis of earth-tide, ocean-tide, and barometric effects, Collier and Hendry Counties, Florida

    USGS Publications Warehouse

    Merritt, Michael L.

    2004-01-01

    Aquifers are subjected to mechanical stresses from natural, non-anthropogenic, processes such as pressure loading or mechanical forcing of the aquifer by ocean tides, earth tides, and pressure fluctuations in the atmosphere. The resulting head fluctuations are evident even in deep confined aquifers. The present study was conducted for the purpose of reviewing the research that has been done on the use of these phenomena for estimating the values of aquifer properties, and determining which of the analytical techniques might be useful for estimating hydraulic properties in the dissolved-carbonate hydrologic environment of southern Florida. Fifteen techniques are discussed in this report, of which four were applied.An analytical solution for head oscillations in a well near enough to the ocean to be influenced by ocean tides was applied to data from monitor zones in a well near Naples, Florida. The solution assumes a completely non-leaky confining unit of infinite extent. Resulting values of transmissivity are in general agreement with the results of aquifer performance tests performed by the South Florida Water Management District. There seems to be an inconsistency between results of the amplitude ratio analysis and independent estimates of loading efficiency. A more general analytical solution that takes leakage through the confining layer into account yielded estimates that were lower than those obtained using the non-leaky method, and closer to the South Florida Water Management District estimates. A numerical model with a cross-sectional grid design was applied to explore additional aspects of the problem.A relation between specific storage and the head oscillation observed in a well provided estimates of specific storage that were considered reasonable. Porosity estimates based on the specific storage estimates were consistent with values obtained from measurements on core samples. Methods are described for determining aquifer diffusivity by comparing the time-varying drawdown in an open well with periodic pressure-head oscillations in the aquifer, but the applicability of such methods might be limited in studies of the Floridan aquifer system.

  3. Can arsenic occurrence rate in bedrock aquifers be predicted?

    USGS Publications Warehouse

    Yang, Qiang; Jung, Hun Bok; Marvinney, Robert G.; Culbertson, Charles W.; Zheng, Yan

    2012-01-01

    A high percentage (31%) of groundwater samples from bedrock aquifers in the greater Augusta area, Maine was found to contain greater than 10 μg L–1 of arsenic. Elevated arsenic concentrations are associated with bedrock geology, and more frequently observed in samples with high pH, low dissolved oxygen, and low nitrate. These associations were quantitatively compared by statistical analysis. Stepwise logistic regression models using bedrock geology and/or water chemistry parameters are developed and tested with external data sets to explore the feasibility of predicting groundwater arsenic occurrence rates (the percentages of arsenic concentrations higher than 10 μg L–1) in bedrock aquifers. Despite the under-prediction of high arsenic occurrence rates, models including groundwater geochemistry parameters predict arsenic occurrence rates better than those with bedrock geology only. Such simple models with very few parameters can be applied to obtain a preliminary arsenic risk assessment in bedrock aquifers at local to intermediate scales at other localities with similar geology.

  4. Can arsenic occurrence rates in bedrock aquifers be predicted?

    PubMed Central

    Yang, Qiang; Jung, Hun Bok; Marvinney, Robert G.; Culbertson, Charles W.; Zheng, Yan

    2012-01-01

    A high percentage (31%) of groundwater samples from bedrock aquifers in the greater Augusta area, Maine was found to contain greater than 10 µg L−1 of arsenic. Elevated arsenic concentrations are associated with bedrock geology, and more frequently observed in samples with high pH, low dissolved oxygen, and low nitrate. These associations were quantitatively compared by statistical analysis. Stepwise logistic regression models using bedrock geology and/or water chemistry parameters are developed and tested with external data sets to explore the feasibility of predicting groundwater arsenic occurrence rates (the percentages of arsenic concentrations higher than 10 µg L−1) in bedrock aquifers. Despite the under-prediction of high arsenic occurrence rates, models including groundwater geochemistry parameters predict arsenic occurrence rates better than those with bedrock geology only. Such simple models with very few parameters can be applied to obtain a preliminary arsenic risk assessment in bedrock aquifers at local to intermediate scales at other localities with similar geology. PMID:22260208

  5. Effect of an offshore sinkhole perforation in a coastal confined aquifer on submarine groundwater discharge

    USGS Publications Warehouse

    Fratesi, S.E.; Leonard, V.; Sanford, W.E.

    2007-01-01

    In order to explore submarine groundwater discharge in the vicinity of karst features that penetrate the confining layer of an offshore, partially confined aquifer, we constructed a three-dimensional groundwater model using the SUTRA (Saturated-Unsaturated TRAnsport) variable-density groundwater flow model. We ran a parameter sensitivity analysis, testing the effects of recharge rates, permeabilities of the aquifer and confining layer, and thickness of the confining layer. In all simulations, less than 20% of the freshwater recharge for the entire model exits through the sinkhole. Recirculated seawater usually accounts for 10-30% of the total outflow from the model. Often, the sinkhole lies seaward of the transition zone and acts as a recharge feature for recirculating seawater. The permeability ratio between aquifer and confining layer influences the configuration of the freshwater wedge the most; as confining layer permeability decreases, the wedge lengthens and the fraction of total discharge exiting through the sinkhole increases. Copyright ?? 2007 IAHS Press.

  6. Impact of model complexity and multi-scale data integration on the estimation of hydrogeological parameters in a dual-porosity aquifer

    NASA Astrophysics Data System (ADS)

    Tamayo-Mas, Elena; Bianchi, Marco; Mansour, Majdi

    2018-03-01

    This study investigates the impact of model complexity and multi-scale prior hydrogeological data on the interpretation of pumping test data in a dual-porosity aquifer (the Chalk aquifer in England, UK). In order to characterize the hydrogeological properties, different approaches ranging from a traditional analytical solution (Theis approach) to more sophisticated numerical models with automatically calibrated input parameters are applied. Comparisons of results from the different approaches show that neither traditional analytical solutions nor a numerical model assuming a homogenous and isotropic aquifer can adequately explain the observed drawdowns. A better reproduction of the observed drawdowns in all seven monitoring locations is instead achieved when medium and local-scale prior information about the vertical hydraulic conductivity (K) distribution is used to constrain the model calibration process. In particular, the integration of medium-scale vertical K variations based on flowmeter measurements lead to an improvement in the goodness-of-fit of the simulated drawdowns of about 30%. Further improvements (up to 70%) were observed when a simple upscaling approach was used to integrate small-scale K data to constrain the automatic calibration process of the numerical model. Although the analysis focuses on a specific case study, these results provide insights about the representativeness of the estimates of hydrogeological properties based on different interpretations of pumping test data, and promote the integration of multi-scale data for the characterization of heterogeneous aquifers in complex hydrogeological settings.

  7. Characterizing Structural and Stratigraphic Heterogeneities in a Faulted Aquifer Using Pump Tests with an Array of Westbay Multilevel Monitoring Wells

    NASA Astrophysics Data System (ADS)

    Johnson, B.; Zhurina, E. N.

    2001-12-01

    We are developing and assessing field testing and analysis methodologies for quantitative characterization of aquifer heterogenities using data measured in an array of multilevel monitoring wells (MLW) during pumping and recovery well tests. We have developed a unique field laboratory to determine the permeability field in a 20m by 40m by 70m volume in the fault partitioned, siliciclastic Hickory aquifer system in central Texas. The site incorporates both stratigraphic variations and a normal fault system that partially offsets the aquifer and impedes cross-fault flow. We constructed a high-resolution geologic model of the site based upon 1050 m of core and a suite of geophysical logs from eleven, closely spaced (3-10m), continuously cored boreholes to depths of 125 m. Westbay multilevel monitoring systems installed in eight holes provide 94 hydraulically isolated measurement zones and 25 injection zones. A good geologic model is critical to proper installation of the MLW. Packers are positioned at all significant fault piercements and selected, laterally extensive, clay-rich strata. Packers in adjacent MLW bracket selected hydrostratigraphic intervals. Pump tests utilized two, uncased, fully penetrating irrigation wells that straddle the fault system and are in close proximity (7 to 65 m) to the MLW. Pumping and recovery transient pressure histories were measured in 85 zones using pressure transducers with a resolution of 55 Pa (0.008 psi). The hydraulic response is that of an anisotropic, unconfined aquifer. The transient pressure histories vary significantly from zone to zone in a single MLW as well as between adjacent MLW. Derivative plots are especially useful for differentiating details of pressure histories. Based on the geologic model, the derivative curve of a zone reflects its absolute vertical position, vertical stratigraphic position, and proximity to either a fault or significant stratigraphic heterogeneity. Additional forward modeling is needed to assist qualitative interpretation of response curves. Prior geologic knowledge appears critical. Quantitative interpretation of the transient pressure histories requires utilizing a numerical aquifer response model coupled with a geophysical inversion algorithm.

  8. Reconnaissance of surface-water quality in the North Platte Natural Resources District, western Nebraska, 1993

    USGS Publications Warehouse

    Steele, G.V.; Cannia, J.C.

    1997-01-01

    In 1993, the U.S. Geological Survey and the North Platte Natural Resources District began a 3-year study to determine the geohydrology and water quality of the North Platte River alluvial aquifer near Oshkosh, Garden County, Nebraska. The objectives of the study were to determine the geohydrologic properties of the North Platte River alluvial aquifer, to establish a well network for long- term monitoring of concentrations of agricultural chemicals including nitrate and herbicides, and to establish baseline concentrations of major ions in the ground water. To meet these objectives, monitor wells were installed at 11 sites near Oshkosh. The geohydrologic properties of the aquifer were estimated from water-level measurements at selected irrigation wells located in the study area and short- term constant-discharge aquifer tests at two monitor wells. Water samples were collected bimonthly and analyzed for specific conductance, pH, water temperature, dissolved oxygen, and nutrients including dissolved nitrate. Samples were collected semiannually for analysis of major ions, and annually for triazine and acetamide herbicides. Evaluation of the aquifer-test data indicates the hydraulic conductivities of the North Platte River alluvial aquifer range between 169 and 184 feet per day and transmissivities ranged from 12,700 to 26,700 feet-squared per day. The average specific yield for the alluvial aquifer, based on the two aquifer tests, was 0.2. Additional hydrologic data for the alluvial aquifer include a horizontal gradient of about 0.002 foot per foot and estimated ground- water flow velocities of about 0.1 to 1.8 feet per day. Evaluation of the water-quality data indicates that nitrate concentrations exceed the U.S. Environmental Protection Agency's (USEPA) Maximum Contamination Level of 10 milligrams per liter for drinking water in areas to the east and west of Oshkosh. In these areas, nitrate concentrations generally are continuing to rise. West of Oshkosh the highest concentrations are now exceeding 50 milligrams per liter. With the exception of one sample, nitrate concentrations exceeding the Maximum Contamination Level were not detected in three wells used to monitor the ground water flowing into and out of the study area, nor in a monitor well located near a municipal well. Results of the study also indicate that an influx of water from Lost Creek Valley, north of the study area, may be mixing with ground water near Oshkosh and diluting concentrations of nitrate.

  9. Effect of wellbore storage and finite thickness skin on flow to a partially penetrating well in a phreatic aquifer

    NASA Astrophysics Data System (ADS)

    Pasandi, M.; Samani, N.; Barry, D. A.

    2008-02-01

    An analytical model is presented for the analysis of constant flux tests conducted in a phreatic aquifer having a partially penetrating well with a finite thickness skin. The solution is derived in the Laplace transform domain for the drawdown in the pumping well, skin and formation regions. The time-domain solution in terms of the aquifer drawdown is then obtained from the numerical inversion of the Laplace transform and presented as dimensionless drawdown-time curves. The derived solution is used to investigate the effects of the hydraulic conductivity contrast between the skin and formation, in addition to wellbore storage, skin thickness, delayed yield, partial penetration and distance to the observation well. The results of the developed solution were compared with those from an existing solution for the case of an infinitesimally thin skin. The latter solution can never approximate that for the developed finite skin. Dimensionless drawdown-time curves were compared with the other published results for a confined aquifer. Positive skin effects are reflected in the early time and disappear in the intermediate and late time aquifer responses. But in the case of negative skin this is reversed and the negative skin also tends to disguise the wellbore storage effect. A thick negative skin lowers the overall drawdown in the aquifer and leads to more persistent delayed drainage. Partial penetration increases the drawdown in the case of a positive skin; however its effect is masked by the negative skin. The influence of a negative skin is pronounced over a broad range of radial distances. At distant observation points the influence of a positive skin is too small to be reflected in early and intermediate time pumping test data and consequently the type curve takes its asymptotic form.

  10. Preliminary data from Arbuckle test wells, Miami, Douglas, Saline, and Labette counties, Kansas

    USGS Publications Warehouse

    Gogel, Tony

    1981-01-01

    Formation data from drill-stem tests are presented for use in calculating transmissivity, hydraulic conductivity, and hydraulic head. Complete analyses of water samples from wells at sites 2, 3, and 4, and a partial analysis at site 1, are presented to indicate water quality in the aquifers.

  11. Groundwater quality assessment in semi-arid regions using integrated approaches: the case of Grombalia aquifer (NE Tunisia).

    PubMed

    Kammoun, Siwar; Trabelsi, Rim; Re, Viviana; Zouari, Kamel; Henchiri, Jihed

    2018-01-19

    As many arid and semi-arid regions in the Mediterranean Basin, the Grombalia coastal aquifer (NE Tunisia) is affected by severe groundwater exploitation and contamination. Therefore, quality assessments are becoming increasingly important as the long-term protection of water resources is at stake. Multidisciplinary investigations, like the one presented in this paper, are particularly effective in identifying the different origins of mineralization within an aquifer and investigating the impact of anthropogenic activities on groundwater quality. An integrated assessment, focused on the combined use of geostatistical, geochemical and isotopic (δ 18 O, δ 2 H and 3 H) tools, was performed in the Grombalia aquifer between February and March 2014. The overall goal was to study the main processes controlling aquifer salinization, with special focus to nitrate contamination. Results indicate a persisting deterioration of water quality over the whole basin except the south-eastern zone juxtaposing the recharge area of the aquifer. Nitrate contents exceed the drinking water standard (50 mg/l) in 70% of groundwater samples, mainly due to the excessive use of fertilizers and urban activities. Stable isotope measurements showed the contribution of modern rainwater to aquifer recharge and proved the presence of evaporation contributing to the salinity increase. Tritium values of groundwater samples suggested two hypotheses: the existence of mixture between old and recent water or/and the existence of two recharge periods of the aquifer, pre- and post-nuclear weapons test. Principal component analysis confirmed the geochemical interpretation, highlighting that water-rock interaction evaporation effect and intensive anthropogenic activities constitute the main processes controlling the regional groundwater mineralization.

  12. Characterizating Multi-layered Coastal Aquifer using Pneumatic Slug Tests

    NASA Astrophysics Data System (ADS)

    Malama, B.; Abere, M.; Mikenna, M.

    2016-12-01

    Results of pneumatic slug tests conducted in a monitoring wells of a shallow aquifer on the California Central Coast are presented. The aquifer is in the Los Osos groundwater basin on the California Central Coast, a semi-closed near-triangular groundwater basin bounded to the north and south by impermeable igneousbed rock and to the west by the Pacific Ocean. The groundwater basin is a multi-layered system comprising a perched, near-surface semi-confined, and a deep confined aquifer. The unincorporated community of Los Osos is wholly dependent on the groundwater basin that is threatened with seawater intrusion and nitratecontamination. The slug tests reported here were performed in the perched and semi-confined aquifers as part of a seawater intrusion characterization study. The semi-confined and confined aquifers show evidence of seawater intrusion with upconing in some deep aquifer municipal wells. The upconing has beeninterpreted by previous studies as evidence of preferential flow through a high permeability channel. The objective of the work was to test this hypothesis by mapping the horizontal and vertical spatial variability of hydraulic parameters across the basin and establish the extent of the high permeability unit.Here only preliminary results of slug tests conducted across the basin for vertically averaged hydraulic parameters are reported. The results provide an indication of the horizontal variability of hydraulic parameters. An additional study will be performed to characterize the vertical variability to investigate the probableexistsence of a high permeability channel.

  13. Automatic estimation of aquifer parameters using long-term water supply pumping and injection records

    NASA Astrophysics Data System (ADS)

    Luo, Ning; Illman, Walter A.

    2016-09-01

    Analyses are presented of long-term hydrographs perturbed by variable pumping/injection events in a confined aquifer at a municipal water-supply well field in the Region of Waterloo, Ontario (Canada). Such records are typically not considered for aquifer test analysis. Here, the water-level variations are fingerprinted to pumping/injection rate changes using the Theis model implemented in the WELLS code coupled with PEST. Analyses of these records yield a set of transmissivity ( T) and storativity ( S) estimates between each monitoring and production borehole. These individual estimates are found to poorly predict water-level variations at nearby monitoring boreholes not used in the calibration effort. On the other hand, the geometric means of the individual T and S estimates are similar to those obtained from previous pumping tests conducted at the same site and adequately predict water-level variations in other boreholes. The analyses reveal that long-term municipal water-level records are amenable to analyses using a simple analytical solution to estimate aquifer parameters. However, uniform parameters estimated with analytical solutions should be considered as first rough estimates. More accurate hydraulic parameters should be obtained by calibrating a three-dimensional numerical model that rigorously captures the complexities of the site with these data.

  14. Improved predictions of saturated and unsaturated zone drawdowns in a heterogeneous unconfined aquifer via transient hydraulic tomography: Laboratory sandbox experiments

    NASA Astrophysics Data System (ADS)

    Berg, Steven J.; Illman, Walter A.

    2012-11-01

    SummaryInterpretation of pumping tests in unconfined aquifers has largely been based on analytical solutions that disregard aquifer heterogeneity. In this study, we investigate whether the prediction of drawdown responses in a heterogeneous unconfined aquifer and the unsaturated zone above it with a variably saturated groundwater flow model can be improved by including information on hydraulic conductivity (K) and specific storage (Ss) from transient hydraulic tomography (THT). We also investigate whether these predictions are affected by the use of unsaturated flow parameters estimated through laboratory hanging column experiments or calibration of in situ drainage curves. To investigate these issues, we designed and conducted laboratory sandbox experiments to characterize the saturated and unsaturated properties of a heterogeneous unconfined aquifer. Specifically, we conducted pumping tests under fully saturated conditions and interpreted the drawdown responses by treating the medium to be either homogeneous or heterogeneous. We then conducted another pumping test and allowed the water table to drop, similar to a pumping test in an unconfined aquifer. Simulations conducted using a variably saturated flow model revealed: (1) homogeneous parameters in the saturated and unsaturated zones have a difficult time predicting the responses of the heterogeneous unconfined aquifer; (2) heterogeneous saturated hydraulic parameter distributions obtained via THT yielded significantly improved drawdown predictions in the saturated zone of the unconfined aquifer; and (3) considering heterogeneity of unsaturated zone parameters produced a minor improvement in predictions in the unsaturated zone, but not the saturated zone. These results seem to support the finding by Mao et al. (2011) that spatial variability in the unsaturated zone plays a minor role in the formation of the S-shape drawdown-time curve observed during pumping in an unconfined aquifer.

  15. KGS-HighK: A Fortran 90 program for simulation of hydraulic tests in highly permeable aquifers

    USGS Publications Warehouse

    Zhan, X.; Butler, J.J.

    2006-01-01

    Slug and pumping tests (hydraulic tests) are frequently used by hydrogeologists to obtain in-situ estimates of the transmissive and storage properties of a formation (Streltsova, 1988; Kruseman and de Ridder, 1990; Butler, 1998). In aquifers of high hydraulic conductivity, hydraulic tests are affected by mechanisms that are not considered in the analysis of tests in less permeable media (Bredehoeft et al., 1966). Inertia-induced oscillations in hydraulic head are the most common manifestation of such mechanisms. Over the last three decades, a number of analytical solutions that incorporate these mechanisms have been developed for the analysis of hydraulic tests in highly permeable aquifers (see Butler and Zhan (2004) for a review of this previous work). These solutions, however, are restricted to a subset of the conditions commonly encountered in the field. Recently, a more general solution has been developed that builds on this previous work to remove many of the limitations imposed by these earlier approaches (Butler and Zhan, 2004). The purpose of this note is to present a Fortran 90 program, KGS-HighK, for the evaluation of this new solution. This note begins with a brief overview of the conceptual model that motivated the development of the solution of Butler and Zhan (2004) for pumping- and slug-induced flow to/from a central well. The major steps in the derivation of that solution are described, but no details are given. Instead, a Mathematica notebook is provided for those interested in the derivation details. The key algorithms used in KGS-HighK are then described and the program structure is briefly outlined. A field example is provided to demonstrate program performance. The note concludes with a short summary section. ?? 2005 Elsevier Ltd. All rights reserved.

  16. Ground-water flow directions and estimation of aquifer hydraulic properties in the lower Great Miami River Buried Valley aquifer system, Hamilton Area, Ohio

    USGS Publications Warehouse

    Sheets, Rodney A.; Bossenbroek, Karen E.

    2005-01-01

    The Great Miami River Buried Valley Aquifer System is one of the most productive sources of potable water in the Midwest, yielding as much as 3,000 gallons per minute to wells. Many water-supply wells tapping this aquifer system are purposely placed near rivers to take advantage of induced infiltration from the rivers. The City of Hamilton's North Well Field consists of 10 wells near the Great Miami River, all completed in the lower Great Miami River Buried Valley Aquifer System. A well-drilling program and a multiple-well aquifer test were done to investigate ground-water flow directions and to estimate aquifer hydraulic properties in the lower part of the Great Miami River Buried Valley Aquifer System. Descriptions of lithology from 10 well borings indicate varying amounts and thickness of clay or till, and therefore, varying levels of potential aquifer confinement. Borings also indicate that the aquifer properties can change dramatically over relatively short distances. Grain-size analyses indicate an average bulk hydraulic conductivity value of aquifer materials of 240 feet per day; the geometric mean of hydraulic conductivity values of aquifer material was 89 feet per day. Median grain sizes of aquifer material and clay units were 1.3 millimeters and 0.1 millimeters, respectively. Water levels in the Hamilton North Well Field are affected by stream stage in the Great Miami River and barometric pressure. Bank storage in response to stream stage is evident. Results from a multiple-well aquifer test at the well field indicate, as do the lithologic descriptions, that the aquifer is semiconfined in some areas and unconfined in others. Transmissivity and storage coefficient of the semiconfined part of the aquifer were 50,000 feet squared per day and 5x10-4, respectively. The average hydraulic conductivity (450 feet per day) based on the aquifer test is reasonable for glacial outwash but is higher than calculated from grain-size analyses, implying a scale effect. Although the part of the lower Great Miami River Buried Valley Aquifer System where the Hamilton North Well Field is located is semiconfined, unconfined, or locally confined and not directly connected to the Great Miami River, the discontinuity of the clay/till layers beneath the river indicates that other, deeper parts of the aquifer system may be directly connected to the Great Miami River.

  17. Thermal well-test method

    DOEpatents

    Tsang, C.F.; Doughty, C.A.

    1984-02-24

    A well-test method involving injection of hot (or cold) water into a groundwater aquifer, or injecting cold water into a geothermal reservoir is disclosed. By making temperature measurements at various depths in one or more observation wells, certain properties of the aquifer are determined. These properties, not obtainable from conventional well test procedures, include the permeability anisotropy, and layering in the aquifer, and in-situ thermal properties. The temperature measurements at various depths are obtained from thermistors mounted in the observation wells.

  18. Thermal well-test method

    DOEpatents

    Tsang, Chin-Fu; Doughty, Christine A.

    1985-01-01

    A well-test method involving injection of hot (or cold) water into a groundwater aquifer, or injecting cold water into a geothermal reservoir. By making temperature measurements at various depths in one or more observation wells, certain properties of the aquifer are determined. These properties, not obtainable from conventional well test procedures, include the permeability anisotropy, and layering in the aquifer, and in-situ thermal properties. The temperature measurements at various depths are obtained from thermistors mounted in the observation wells.

  19. Modelling Contributions of the Local and Regional Groundwater Flow of Managed Aquifer Recharge Activities at Querença-Silves Aquifer System.

    NASA Astrophysics Data System (ADS)

    Costa, Luís; Monteiro, José Paulo; Oliveira, Manuel; Mota, Rogério; Lobo-Ferreira, João Paulo; Martins de Carvalho, José; Martins de Carvalho, Tiago; Agostinho, Rui; Hugman, Rui

    2015-04-01

    The Querença-Silves (QS) aquifer system is one of the most important natural groundwater reservoirs in the Algarve region of southern Portugal. With a surface area of 324 km2, this karst aquifer system is the main source of supply for irrigation as well as an important source of water for the urban supply. Due to the importance given to QS aquifer system by both governmental actors and end users, ongoing research during the last two decades at the University of Algarve has attempted to provide a better understanding of the hydrogeology and hydraulic behavior, which has resulted in the development of regional scale numerical models. The most recent hydrogeological data has been acquired during the ongoing MARSOL project (MARSOL-GA-2013-619120) which aims to demonstrate that Managed Aquifer Recharge (MAR) is a sound, safe and sustainable strategy that can be applied with great confidence in finding solutions to water scarcity in Southern Europe. Within the scope of the project large diameter well injection tests (with and without tracers) as well as geophysical surveys have been carried out in order to determine the infiltration capacity and aquifer properties. The results of which allowed the use of analytical methods to determine local scale values of hydraulic parameters (e.g. hydraulic conductivity and storage coefficient). These values will be compared with results from pre-existing numerical flow and transport models in order to obtain complementary solutions to the problem at local and regional scales. This analysis will contribute to the selection of the most appropriate methods to interpret, reproduce and model the impacts of MAR activities planned within the scope of the MARSOL project. Subsequent to the planned injection tests and, with the support of modelling efforts, the capacity of infiltration of rejected water from water treatment plants or surface storage dams in the large diameter well will be assessed.

  20. Interests of long-term hydrogeological observatories for characterizing and modelling heterogeneous groundwater systems at multiple temporal and spatial scales: the example of Ploemeur, a crystalline rock aquifer (Brittany).

    NASA Astrophysics Data System (ADS)

    Bour, Olivier; Longuervergne, Laurent; Le Borgne, Tanguy; Lavenant, Nicolas; de Dreuzy, Jean-Raynald; Schuite, Jonathan; Labasque, Thierry; Aquilina, Luc; Davy, Philippe

    2017-04-01

    Characterizing groundwater flows and surface interactions in heterogeneous groundwater systems such as crystalline fractured rock is often extremely complex. In particular, hydraulic properties are highly variable while groundwater chemical properties may vary both in space and time, especially due to the impact of groundwater abstraction. Here, we show the interest of hydrological observatories and long-term monitoring for characterizing hydrological processes occurring in a crystalline rock aquifer. We present results from the site of Ploemeur (French Brittany) that belongs to the network of hydrogeological sites H+ and the research infrastructure OZCAR, and where interdisciplinary and integrated research at multiple temporal and spatial scales has been developed for almost twenty years. This outstandingly heterogeneous crystalline rock aquifer is also used for groundwater supply since 1991. In particular, we show how cross-borehole flowmeter tests, pumping tests and a frequency domain analysis of groundwater levels allow quantifying the hydraulic properties of the aquifer at different scales. In addition, groundwater temperature evolution was used as an excellent tracer for characterizing groundwater flow. At the site scale, measurements of ground surface deformation through long-base tiltmeters provide robust estimates of aquifer storage and allow identifying the active structures, including those acting during recharge process. Finally, a numerical model of the watershed scale that combines hydraulic data and groundwater ages confirms the geometry of this complex aquifer and the consistency of the different datasets. In parallel, this hydrological observatory is also used for developing hydrogeophysical methods and to characterize groundwater transport and biogeochemical reactivity in the sub-surface. The Ploemeur hydrogeological observatory is a good example of the interest of focusing research activities on a site during long-term as it provides a thorough understanding of both hydrological and biogeochemical processes that can be extended to many heterogeneous aquifers.

  1. Aquifer Tests and Characterization of Transmissivity, Ada-Vamoosa Aquifer on the Osage Reservation, Osage County, Oklahoma, 2006

    USGS Publications Warehouse

    Abbott, Marvin M.; DeHay, Kelli

    2008-01-01

    The Ada-Vamoosa aquifer of northeastern Oklahoma is a sedimentary bedrock aquifer of Pennsylvanian age that crops out over 800 square miles of the Osage Reservation. The Osage Nation needed additional information regarding the production potential of the aquifer to aid them in future development planning. To address this need, the U.S. Geological Survey, in cooperation with the Osage Nation, conducted a study of aquifer properties in the Ada-Vamoosa aquifer. This report presents the results of the aquifer tests from 20 wells in the Ada-Vamoosa aquifer and one well in a minor aquifer east of the Ada-Vamoosa outcrop on the Osage Reservation. Well information for 17 of the 21 wells in this report was obtained from the Indian Health Service. Data collected by the U.S. Geological Survey during this investigation are pumping well data from four domestic wells collected during the summer of 2006. Transmissivity values were calculated from well pumping data or were estimated from specific capacity values depending on the reliability of the data. The estimated transmissivity values are 1.1 to 4.3 times greater than the calculated transmissivity values. The calculated and estimated transmissivity values range from 5 to 1,000 feet squared per day.

  2. The Impact of the Degree of Aquifer Confinement and Anisotropy on Tidal Pulse Propagation.

    PubMed

    Shuai, Pin; Knappett, Peter S K; Hossain, Saddam; Hosain, Alamgir; Rhodes, Kimberly; Ahmed, Kazi Matin; Cardenas, M Bayani

    2017-07-01

    Oceanic tidal fluctuations which propagate long distances up coastal rivers can be exploited to constrain hydraulic properties of riverbank aquifers. These estimates, however, may be sensitive to degree of aquifer confinement and aquifer anisotropy. We analyzed the hydraulic properties of a tidally influenced aquifer along the Meghna River in Bangladesh using: (1) slug tests combined with drilling logs and surface resistivity to estimate Transmissivity (T); (2) a pumping test to estimate T and Storativity (S) and thus Aquifer Diffusivity (D PT ); and (3) the observed reduction in the amplitude and velocity of a tidal pulse to calculate D using the Jacob-Ferris analytical solution. Average Hydraulic Conductivity (K) and T estimated with slug tests and borehole lithology were 27.3 m/d and 564 m 2 /d, respectively. Values of T and S determined from the pumping test ranged from 400 to 500 m 2 /d and 1 to 5 × 10 -4 , respectively with D PT ranging from 9 to 40 × 10 5  m 2 /d. In contrast, D estimated from the Jacob-Ferris model ranged from 0.5 to 9 × 10 4  m 2 /d. We hypothesized this error resulted from deviations of the real aquifer conditions from those assumed by the Jacob-Ferris model. Using a 2D numerical model tidal pulses were simulated across a range of conditions and D was calculated with the Jacob-Ferris model. Moderately confined (K top /K aquifer  < 0.01) or anisotropic aquifers (K x /K z  > 10) yield D within a factor of 2 of the actual value. The order of magnitude difference in D between pumping test and Jacob-Ferris model at our site argues for little confinement or anisotropy. © 2017, National Ground Water Association.

  3. Simulation of water-table aquifers using specified saturated thickness

    USGS Publications Warehouse

    Sheets, Rodney A.; Hill, Mary C.; Haitjema, Henk M.; Provost, Alden M.; Masterson, John P.

    2014-01-01

    Simulating groundwater flow in a water-table (unconfined) aquifer can be difficult because the saturated thickness available for flow depends on model-calculated hydraulic heads. It is often possible to realize substantial time savings and still obtain accurate head and flow solutions by specifying an approximate saturated thickness a priori, thus linearizing this aspect of the model. This specified-thickness approximation often relies on the use of the “confined” option in numerical models, which has led to confusion and criticism of the method. This article reviews the theoretical basis for the specified-thickness approximation, derives an error analysis for relatively ideal problems, and illustrates the utility of the approximation with a complex test problem. In the transient version of our complex test problem, the specified-thickness approximation produced maximum errors in computed drawdown of about 4% of initial aquifer saturated thickness even when maximum drawdowns were nearly 20% of initial saturated thickness. In the final steady-state version, the approximation produced maximum errors in computed drawdown of about 20% of initial aquifer saturated thickness (mean errors of about 5%) when maximum drawdowns were about 35% of initial saturated thickness. In early phases of model development, such as during initial model calibration efforts, the specified-thickness approximation can be a very effective tool to facilitate convergence. The reduced execution time and increased stability obtained through the approximation can be especially useful when many model runs are required, such as during inverse model calibration, sensitivity and uncertainty analyses, multimodel analysis, and development of optimal resource management scenarios.

  4. Hydrology of the Tertiary-Cretaceous aquifer system in the vicinity of Fort Rucker Aviation Center, Alabama

    USGS Publications Warehouse

    Scott, J.C.; Law, L.R.; Cobb, Riley

    1984-01-01

    Fort Rucker Aviation Center, built in 1941-42, uses ground water for its water supply. The demand for water began to exceed the capacity of the well field in 1976. The Tertiary-Cretaceous aquifer system in the Fort Rucker area consists of an upper and lower aquifer. The upper aquifer consists of the basal part of the Tuscahoma Sand, the Nanafalia and Clayton Formations, and the upper part of the Providence Sand. The lower aquifer consists of the lower part of the Providence Sand and the Ripley Formation. Most large capacity (greater than 100 gal/min (gallons per minute)) wells in the Fort Rucker area are developed in one of these aquifers, and produce 500 gal/min or more. An aquifer test made at Fort Rucker during the study indicates that the transmissivity of the upper aquifer is about 7,000 ft sq/d (feet squared per day). This test and a potentiometric map of the area indicate that wells spaced too closely together is a major problem at pumping centers in the study area. (USGS)

  5. Insights on pumping well interpretation from flow dimension analysis: The learnings of a multi-context field database

    NASA Astrophysics Data System (ADS)

    Ferroud, Anouck; Chesnaux, Romain; Rafini, Silvain

    2018-01-01

    The flow dimension parameter n, derived from the Generalized Radial Flow model, is a valuable tool to investigate the actual flow regimes that really occur during a pumping test rather than suppose them to be radial, as postulated by the Theis-derived models. A numerical approach has shown that, when the flow dimension is not radial, using the derivative analysis rather than the conventional Theis and Cooper-Jacob methods helps to estimate much more accurately the hydraulic conductivity of the aquifer. Although n has been analysed in numerous studies including field-based studies, there is a striking lack of knowledge about its occurrence in nature and how it may be related to the hydrogeological setting. This study provides an overview of the occurrence of n in natural aquifers located in various geological contexts including crystalline rock, carbonate rock and granular aquifers. A comprehensive database is compiled from governmental and industrial sources, based on 69 constant-rate pumping tests. By means of a sequential analysis approach, we systematically performed a flow dimension analysis in which straight segments on drawdown-log derivative time series are interpreted as successive, specific and independent flow regimes. To reduce the uncertainties inherent in the identification of n sequences, we used the proprietary SIREN code to execute a dual simultaneous fit on both the drawdown and the drawdown-log derivative signals. Using the stated database, we investigate the frequency with which the radial and non-radial flow regimes occur in fractured rock and granular aquifers, and also provide outcomes that indicate the lack of applicability of Theis-derived models in representing nature. The results also emphasize the complexity of hydraulic signatures observed in nature by pointing out n sequential signals and non-integer n values that are frequently observed in the database.

  6. Internal Technical Report, 1981 Annual Report, An Analysis of the Response of the Raft River Geothermal Site Monitor Wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thurow, T.L.; Large, R.M.; Allman, D.W.

    1982-04-01

    A groundwater monitoring program has been established on the Raft River Geothermal Site since 1978. The objective of this program is to document possible impacts that may be caused by geothermal production and injection on the shallow aquifers used for culinary and irrigation purposes. This annual progress report summarizes data from 12 monitor wells during 1981. These data are compared with long-term trends and are correlated with seasonal patterns, irrigation water use and geothermal production and testing. These results provide a basis for predicting long-term impacts of sustained geothermal production and testing. To date, there has been no effect onmore » the water quality of the shallow aquifers.« less

  7. Studies and projections of hydraulic conductivity of Devonian Plavinu and Daugava carbonate aquifers in Latvia

    NASA Astrophysics Data System (ADS)

    Perkone, E.; Delina, A.; Saks, T.; Raga, B.; Jātnieks, J.; Klints, I.; Popovs, K.; Babre, A.; Bikše, J.; Kalvāns, A.; Retike, I.; Ukass, J.

    2012-04-01

    Carbonate aquifers show a very wide range of hydrogeological characteristics. Carbonate rock hydrogeology display two extremes: on one hand hydrogeological properties of the carbonates are governed by the pathways of the preferential groundwater flow typical in karstic regions, on the other - some carbonate aquifers behave almost like a homogeneous, isotropic, porous medium. Most lie between these extremes, but these case variations complicates the study of carbonate aquifer properties. In this study the results of the hydraulic conductivity in carbonate aquifers measurements, hydraulic conductivity correlation between sediments lithology and the aquifer surface depth and fractures research is presented. Upper Devonian Frasnian stage Pļaviņu and Daugava carbonate aquifers in the Latvian part of the Baltic basin is considered. The aim of this research is to elaborate characteristic hydraulic conductivity values for each aquifer based on existing data of the pumping test results and other aquifer properties. Pļaviņu and Daugava carbonate aquifers mainly consist of jointed dolomite with intermediate layers of dolomitic marlstone, limestone, clays and gypsum. These aquifers are prevalent in most of the study area, except Northern and South - Eastern parts of the territory. In geological structure Daugava aquifer lies above Pļaviņu aquifer. Daugava aquifer depth changes from 10 - 20 and even less meters in Eastern part to 250 - 300 m in South - West part of study area, but thickness varies from few meters to 30 m. Pļaviņu aquifer surface depth varies from 20 - 30 m, but in uplands surface depth reaches more than 120 m, in Eastern part to more than 300 m in South - West part of study area. Aquifer average thickness varies from 20 - 40 m, but in areas with buried valleys thickness can be less than 10 meters. Outcrops of these sediments are occurring in banks of largest rivers and in some areas aquifers are karstified. In studies of the carbonate aquifers it is very important to take into account the fact that groundwater flow in carbonate aquifers is often almost entirely dependent on jointing and concomitant joint enlargement by dissolution. In this study pumping test results provide a wide range of hydraulic conductivity values, for example in Pļaviņu aquifer hydraulic conductivity varies from 0,03 - 266 m/day but in Daugava aquifer values range from 0,06 - 735 m/day. Pumping test results is provided by Latvian Environment, Geology and Meteorology Centre. Studying average values of hydraulic conductivity there exists a correlation between K and aquifer flat depth - Daugava aquifer, which in geological structure, is located above the Pļaviņu aquifer has higher average K value - 32 m/day, in Pļaviņu aquifer - 27 m/day. Correlative study of the depth and hydraulic conductivity allowed to characterize the mean values as function of the aquifer depth for the regional groundwater flow modelling. This study is supported by the European Social Fund project No. 2009/0212/1DP/1.1.1.2.0/09/APIA/VIAA/060

  8. SlugIn 1.0: A Free Tool for Automated Slug Test Analysis.

    PubMed

    Martos-Rosillo, Sergio; Guardiola-Albert, Carolina; Padilla Benítez, Alberto; Delgado Pastor, Joaquín; Azcón González, Antonio; Durán Valsero, Juan José

    2018-05-01

    The correct characterization of aquifer parameters is essential for water-supply and water-quality investigations. Slug tests are widely used for these purposes. While free software is available to interpret slug tests, some codes are not user-friendly, or do not include a wide range of methods to interpret the results, or do not include automatic, inverse solutions to the test data. The private sector has also generated several good programs to interpret slug test data, but they are not free of charge. The computer program SlugIn 1.0 is available online for free download, and is demonstrated to aid in the analysis of slug tests to estimate hydraulic parameters. The program provides an easy-to-use Graphical User Interface. SlugIn 1.0 incorporates automated parameter estimation and facilitates the visualization of several interpretations of the same test. It incorporates solutions for confined and unconfined aquifers, partially penetrating wells, skin effects, shape factor, anisotropy, high hydraulic conductivity formations and the Mace test for large-diameter wells. It is available in English and Spanish and can be downloaded from the web site of the Geological Survey of Spain. Two field examples are presented to illustrate how the software operates. © 2018, National Ground Water Association.

  9. Recovery of Ground-Water Levels from 1988 to 2003 and Analysis of Effects of 2003 and Full-Allocation Withdrawals in Critical Area 2, Southern New Jersey

    USGS Publications Warehouse

    Spitz, Frederick J.; dePaul, Vincent T.

    2008-01-01

    Water levels in the Potomac-Raritan-Magothy aquifer system within Water Supply Critical Area 2 in the southern New Jersey Coastal Plain have recovered as a result of reductions in ground-water withdrawals initiated in the early 1990s. The Critical Area consists of the depleted zone and the threatened margin. The Potomac-Raritan-Magothy aquifer system consists of the Upper, Middle, and Lower aquifers. Generally, ground-water withdrawals from these aquifers declined 5 to 10 Mgal/d (million gallons per day) and water levels recovered 0 to 40 ft (foot) from 1988 to 2003. In order to reevaluate water-allocation restrictions in Critical Area 2 in response to changes in the ground-water-flow system and demands for additional water supply due to increased development, the New Jersey Department of Environmental Protection (NJDEP) needs information about the effects of changes in those allocations. Therefore, the U.S. Geological Survey (USGS), in cooperation with the NJDEP, used an existing ground-water-flow model of the New Jersey Coastal Plain to evaluate the effects of withdrawal alternatives on hydraulic heads in the Potomac-Raritan-Magothy aquifer system in Critical Area 2. The U.S. Geological Survey Regional Aquifer System Analysis model was used to simulate steady-state ground-water flow. Two withdrawal conditions were tested by using the model to evaluate hydraulic heads and differences in heads in these aquifers: 2003 withdrawals and full-allocation withdrawals (17.4 Mgal/d greater than 2003 withdrawals). Model results are presented using head maps and head-difference maps that compare 2003 to full-allocation withdrawals. Mandated hydrologic conditions for Critical Area protection are that the simulated -30-ft head contour not extend beyond the boundary of the depleted zone and (or) be at least 5 mi (miles) updip from the 250-mg/L (milligram per liter) isochlor in all three aquifers. Simulation results indicate that, for 2003 withdrawals, the simulated -30-ft head contour in all three aquifers is generally within the boundary of the depleted zone, except in the Lower aquifer in northern Camden and northwestern Burlington Counties, and is generally 1 to 10 mi downdip from the 250-mg/L isochlor. (Corresponding observed data indicate that the -30-ft water-level contour extends beyond the southwest boundary of the depleted zone in the Upper and Middle aquifers, and is generally 5 to 20 mi downdip from the 250-mg/L isochlor in all three aquifers.) The area in which heads are below -30 ft ranges from 389 mi2 (square miles) in the Middle aquifer to 427 mi2 in the Lower aquifer. For full-allocation withdrawals, the simulated -30-ft head contour extends beyond the boundary of the depleted zone in all three aquifers in northern Camden and northwestern Burlington Counties and in the Upper aquifer in Gloucester and Salem Counties, and is generally 5 to 15 mi downdip from the 250-mg/L isochlor. The area in which heads are below -30 ft ranges from 616 mi2 in the Upper aquifer to 813 mi2 in the Lower aquifer. These results and observed data indicate that any increase in withdrawals from 2003 values would likely cause heads in the three aquifers to decline below the minimum values mandated by the NJDEP for the Critical Area.

  10. Groundwater recharge in irrigated semi-arid areas: quantitative hydrological modelling and sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Jiménez-Martínez, Joaquín; Candela, Lucila; Molinero, Jorge; Tamoh, Karim

    2010-12-01

    For semi-arid regions, methods of assessing aquifer recharge usually consider the potential evapotranspiration. Actual evapotranspiration rates can be below potential rates for long periods of time, even in irrigated systems. Accurate estimations of aquifer recharge in semi-arid areas under irrigated agriculture are essential for sustainable water-resources management. A method to estimate aquifer recharge from irrigated farmland has been tested. The water-balance-modelling approach was based on VisualBALAN v. 2.0, a computer code that simulates water balance in the soil, vadose zone and aquifer. The study was carried out in the Campo de Cartagena (SE Spain) in the period 1999-2008 for three different groups of crops: annual row crops (lettuce and melon), perennial vegetables (artichoke) and fruit trees (citrus). Computed mean-annual-recharge values (from irrigation+precipitation) during the study period were 397 mm for annual row crops, 201 mm for perennial vegetables and 194 mm for fruit trees: 31.4, 20.7 and 20.5% of the total applied water, respectively. The effects of rainfall events on the final recharge were clearly observed, due to the continuously high water content in soil which facilitated the infiltration process. A sensitivity analysis to assess the reliability and uncertainty of recharge estimations was carried out.

  11. Field testing of aquifer thermal energy storage

    NASA Astrophysics Data System (ADS)

    Kannberg, L. D.; Allen, R. D.

    1984-03-01

    Results of field and laboratory studies of aquifer thermal energy storage (ATES) indicate both the problems and promise of the concept. Geohydrothermal modeling and field testing demonstrated the ability to recover substantial quantities of aquifer stored energy. However, the local hydrologic conditions play an important role in determining the recovery temperature and storage efficiency. Geochemistry is also an important factor, particularly for higher temperature ATES systems.

  12. Determination of hydraulic conductivity in three dimensions and its relation to dispersivity: Chapter D in Ground-water contamination by crude oil at the Bemidji, Minnesota, research site; US Geological Survey Toxic Waste--ground-water contamination study

    USGS Publications Warehouse

    1984-01-01

    Recent investigations suggest that dispersion in aquifers is scale dependent and a function of the heterogeneity of aquifer materials. Theoretical stochastic studies indicate that determining hydraulic-conductivity variability in three dimensions is important in analyzing the dispersion process. Even though field methods are available to approximate hydraulic conductivity in three dimensions, the methods are not generally used because of high cost of field equipment and because measurement and analysis techniques are cumbersome and time consuming. The hypothesis of this study is that field-determined values of dispersivity are scale dependent and that they may be described as a function of hydraulic conductivity in three dimensions. The objectives of the study at the Bemidji research site are to (1) determine hydraulic conductivity of the porous media in three dimensions, (2) determine field values of dispersivity and its scale dependence on hydraulic conductivity, and (3) develop and apply a computerized data-collection, storage, and analysis system for field use in comprehensive determination of hydraulic conductivity and dispersivity. Plans for this investigation involve a variety of methods of analysis. Hydraulic conductivity will be determined separately in the horizontal and vertical planes of the hydraulic-conductivity ellipsoid. Field values of dispersivity will be determined by single-well and doublet-well injection or withdrawal tests with tracers. A computerized data-collection, storage, and analysis system to measure pressure, flow rate, tracer concentrations, and temperature will be designed for field testing. Real-time computer programs will be used to analyze field data. The initial methods of analysis will be utilized to meet the objectives of the study. Preliminary field data indicate the aquifer underlying the Bemidji site is vertically heterogeneous, cross-bedded outwash. Preliminary analysis of the flow field around a hypothetical doublet-well tracer test indicates that the location of the wells can affect the field value of dispersivity. Preliminary analysis also indicates that different values of dispersivity may result from anisotropic conditions in tests in which observation wells are located at equal radial distances from either the injection or withdrawal well.

  13. Reactive solute transport in an asymmetric aquifer-aquitard system with scale-dependent dispersion

    NASA Astrophysics Data System (ADS)

    Zhou, R.; Zhan, H.

    2017-12-01

    Abstract: The understanding of reactive solute transport in an aquifer-aquitard system is important to study transport behavior in the more complex porous media. When transport properties are asymmetric in the upper and lower aquitards, reactive solute transport in such an aquifer-aquitard system becomes a coupled three domain problem that is more complex than the symmetric case in which the upper and lower aquitards have identical transport properties. Meanwhile, the dispersivity of transport in the aquifer is considered as a linear or exponential function of travel distance due to the heterogeneity of aquifer. This study proposed new transport models to describe reactive solute transport in such an asymmetric aquifer-aquitard system with scale-dependent dispersion. Mathematical models were developed for such problems under the first-type and third-type boundary conditions to analyze the spatial-temporal concentration and mass distribution in the aquifer and aquitards with the help of Laplace transform technique and the de Hoog numerical Laplace inversion method. Breakthrough curves (BTCs) and residence time distribution curves (RTDs) obtained from the models with scale-dependent dispersion, constant dispersion and constant effective dispersivity were compared to reflect the lumped scale-dispersion effect in the aquifer-aquitard system. The newly acquired solutions were then tested extensively against previous analytical and numerical solutions and were proven to be robust and accurate. Furthermore, to study the back diffusion of contaminant mass in aquitards, a zero-contaminant mass concentration boundary condition was imposed on the inlet boundary of the system after a certain time, which is also called the process of water flushing. The diffusion loss alone the aquifer/aquitard interfaces and mass stored ratio change in each of three domains (upper aquitard, aquifer, and lower aquitard) after water flushing provided an insightful and comprehensive analysis of transport behavior with asymmetric distribution of transport properties.

  14. Analytical Solution for Flow to a Partially Penetrating Well with Storage in a Confined Aquifer

    NASA Astrophysics Data System (ADS)

    Vesselinov, V. V.; Mishra, P. K.; Neuman, S. P.

    2009-12-01

    Analytical solutions for radial flow toward a pumping well are commonly applied to analyze pumping tests conducted in confined aquifers. However, the existing analytical solutions are not capable to simultaneously take into account aquifer anisotropy, partial penetration, and wellbore storage capacity of pumping well. Ignoring these effects may have important impact on the estimated aquifer properties. We present a new analytical solution for three-dimensional, axially symmetric flow to a pumping well in confined aquifer that accouts for aquifer anisotropy, partial penetration and wellbore storage capacity of pumping well. Our analytical reduces to that of Papadopulos et.al. [1967] when the pumping well is fully penetrating, Hantush [1964] when the pumping well has no wellbore storage, and Theis [1935] when both conditions are fulfilled. The solution is evaluated through numerical inversion of its Laplace transform. We use our new solution to analyze data from synthetic and real pumping tests.

  15. PERFORMANCE AND ANALYSIS OF AQUIFER TESTS WITH IMPLICATIONS FOR CONTAMINANT TRANSPORT MODELING

    EPA Science Inventory

    The scale-dependence of dispersivity values used in contaminant transport models to estimate the spreading of contaminant plumes by hydrodynamic dispersion processes was investigated and found to be an artifact of conventional modeling approaches (especially, vertically averaged ...

  16. Hydrogeology of the surficial aquifer system, Dade County, Florida

    USGS Publications Warehouse

    Fish, J.E.; Stewart, M.T.

    1991-01-01

    An investigation of the surficial aquifer system in Dade County, begun in 1983, is part of a regional study of the aquifer system in southeastern Florida. Test drilling for lithologic samples, flow measurements during drilling, aquifer testing, and analyses of earlier data permitted delineation of the hydraulic conductivity distribution (on hydrogeologic sections), the aquifers in the system, the generalized transmissivity distribution, and interpretation of the ground-water flow system. The surficial aquifer system, in which an unconfined ground-water flow system exists, is composed of the sediments from land surface downward to the top of a regionally extensive zone of sediments of low permeability called the intermediate confining unit. The aquifer system units, which vary in composition from clay-size sediments to cavernous limestone, are hydro stratigraphically divided into the Biscayne aquifer at the top; an intervening semiconfining unit that consists principally of clayey sand; a predominantly gray limestone aquifer in the Tamiami Formation in western and west-central Dade County; and sand or clayey sand near the base of the surficial aquifer system. The base of the surficial aquifer system ranges from a depth of about 175 to 210 feet below land surface in westernmost Dade County to greater than 270 feet in northeastern Dade County. Test drilling and aquifer-test data indicate a complex hydraulic conductivity distribution. Hydraulic conductivities of the very highly permeable zone of the Biscayne aquifer commonly exceed 10,000 feet per day; in the gray limestone aquifer, they range from 210 to 780 feet per day. Transmissivities of the surficial aquifer system vary locally but have a recognizable areal trend. Estimated values generally are about 300,000 feet squared per day or greater in nearly all of central and eastern Dade County. Transmissivity is lower to the west, decreasing to less than 75,000 feet squared per day in western Dade County. High transmissivity usually is associated with thick sections of the Fort Thompson Formation within the Biscayne aquifer. The gray limestone aquifer of the Tamiami Formation has transmissivities that range from 5,800 to 39,000 feet squared per day in western Dade County. The transition from high transmissivity to relatively low transmissivity is often only a few miles wide and coincides with the decrease in thickness of the very highly permeable Fort Thompson Formation, which marks the western boundary of the Biscayne aquifer. More effective drainage as a result of extensive canal systems and large-scale pumping from municipal well fields has greatly altered the predevelopment flow system in eastern Dade County by: (1) eliminating or greatly reducing a seasonal and coastal ground-water ridge; (2) reducing deep circulation; (3) reducing or eliminating seasonal westward movement of ground water; (4) causing accelerated stormwater runoff and short ground-water flow paths; and (5) generally lowering the water table and inducing saltwater intrusion. Under predevelopment conditions in western Dade County, water entered the gray limestone aquifer by lateral movement from Broward and Collier Counties, and by downward seepage from The Everglades and the Biscayne aquifer, and moved southward and southeastward into Dade County to coastal discharge areas. Circulation in the Biscayne aquifer inland also was primarily to the south and southeast. In eastern Dade County, the seasonal ground-water ridge that formed under predevelopment conditions supported both easterly and westerly ground-water flow away from the ridge axis. This seasonal flow created a zone of lower dissolved solids.

  17. Hydraulic head applications of flow logs in the study of heterogeneous aquifers

    USGS Publications Warehouse

    Paillet, Frederick L.

    2001-01-01

    Permeability profiles derived from high-resolution flow logs in heterogeneous aquifers provide a limited sample of the most permeable beds or fractures determining the hydraulic properties of those aquifers. This paper demonstrates that flow logs can also be used to infer the large-scale properties of aquifers surrounding boreholes. The analysis is based on the interpretation of the hydraulic head values estimated from the flow log analysis. Pairs of quasi-steady flow profiles obtained under ambient conditions and while either pumping or injecting are used to estimate the hydraulic head in each water-producing zone. Although the analysis yields localized estimates of transmissivity for a few water-producing zones, the hydraulic head estimates apply to the farfield aquifers to which these zones are connected. The hydraulic head data are combined with information from other sources to identify the large-scale structure of heterogeneous aquifers. More complicated cross-borehole flow experiments are used to characterize the pattern of connection between large-scale aquifer units inferred from the hydraulic head estimates. The interpretation of hydraulic heads in situ under steady and transient conditions is illustrated by several case studies, including an example with heterogeneous permeable beds in an unconsolidated aquifer, and four examples with heterogeneous distributions of bedding planes and/or fractures in bedrock aquifers.

  18. Hydrogeology of the Croton-Ossining area, Westchester County, New York

    USGS Publications Warehouse

    Reynolds, Richard J.

    1988-01-01

    The hydrogeology of a 29-sq-mi area surrounding the village of Croton-on-Hudson, New York, is summarized on 6 sheets at 1:12 ,000 scale that show locations of wells and test holes, surficial geology, geologic sections, bedrock geology, land use, and soil permeability. The primary stratified-drift aquifer in this area is the Croton River aquifer, which consists of outwash sand and gravel that partly fills the Croton River valley from the New Croton Dam to the Hudson River--a distance of approximately 3 miles. The valley is narrow and ranges in width from 100 to 1,900 ft, and its v-notch bedrock floor ranges from 30 to 50 ft below sea level. Detailed hydrogeologic studies during 1936-38 showed the stratigraphy to consist of an upper water-table aquifer with a saturated thickness of about 35 ft, underlain by a silt and clay confining unit 8 to o0 ft in thickness that in turn is underlain by a lower confined outwash aquifer up to 40 ft thick. Aquifer-test data and laboratory permeability tests show that the average hydraulic conductivity of the upper outwash aquifer is 475 ft/d, and that of the lower confined aquifer is about 300 ft/d. The aquifer is recharged through direct precipitation, runoff from adjacent hillsides, and leakage under the new Croton Dam. Previous studies estimate the average leakage under the dam to be 0.65 Mgal/d and the total average daily recharge to the aquifer between New Croton Dam and Quaker Bridge to be 1.73 Mgal/d. (USGS)

  19. Big Data Processing for a Central Texas Groundwater Case Study

    NASA Astrophysics Data System (ADS)

    Cantu, A.; Rivera, O.; Martínez, A.; Lewis, D. H.; Gentle, J. N., Jr.; Fuentes, G.; Pierce, S. A.

    2016-12-01

    As computational methods improve, scientists are able to expand the level and scale of experimental simulation and testing that is completed for case studies. This study presents a comparative analysis of multiple models for the Barton Springs segment of the Edwards aquifer. Several numerical simulations using state-mandated MODFLOW models ran on Stampede, a High Performance Computing system housed at the Texas Advanced Computing Center, were performed for multiple scenario testing. One goal of this multidisciplinary project aims to visualize and compare the output data of the groundwater model using the statistical programming language R to find revealing data patterns produced by different pumping scenarios. Presenting data in a friendly post-processing format is covered in this paper. Visualization of the data and creating workflows applicable to the management of the data are tasks performed after data extraction. Resulting analyses provide an example of how supercomputing can be used to accelerate evaluation of scientific uncertainty and geological knowledge in relation to policy and management decisions. Understanding the aquifer behavior helps policy makers avoid negative impact on the endangered species, environmental services and aids in maximizing the aquifer yield.

  20. Extent and source of saltwater intrusion into the alluvial aquifer near Brinkley, Arkansas, 1984

    USGS Publications Warehouse

    Morris, E.E.; Bush, W.V.

    1986-01-01

    An approximate area of 56 sq mi of the alluvial aquifer just north of Brinkley, Arkansas, has been contaminated by saltwater (chloride concentration > or = 50 mg/L) intruded from underlying aquifers. The contamination was mapped from water quality data for 217 wells. Saltwater problems appear to have spread rapidly in the alluvial aquifer since the late 1940's. Chemical comparisons indicate that the alluvial aquifer was contaminated by water from the Sparta aquifer which in turn was contaminated by the underlying Nacatoch aquifer. The possibility of intrusion into the alluvial aquifer through abandoned oil and gas test wells was investigated but no evidence could be found to support this possibility. Upward movement into the alluvial aquifer from the underlying Sparta aquifer through the thinned or absent Jackson confining unit appears to be the principal reason for saltwater in the alluvial aquifer. Increased withdrawals of water from the alluvial aquifer for irrigation and public supply appear to have contributed to this upward movement. (Author 's abstract)

  1. Induced recharge of an artesian glacial-drift aquifer at Kalamazoo, Michigan

    USGS Publications Warehouse

    Reed, J.E.; Deutsch, Morris; Wiitala, S.W.

    1966-01-01

    As part of a program for managing its ground-water supply, the city of Kalamazoo has constructed induced-recharge facilities at the sites of several of its well fields. To determine the benefits of induced recharge in a water-management program, the U.S. Geological Survey, in cooperation with the city, conducted a series of field experiments at a city well field (Station 9). The 12 production wells at the test site penetrate about 160 feet of glacial drift, which can be separated into three general units a lower aquifer, an intervening confining layer, and an upper aquifer. Although the upper aquifer is not tapped by any of the municipal supply wells, it serves as a storage and transmission medium for water from the West Fork Portage Creek. The testing program consisted of four aquifer and three recharge tests. The aquifer tests show that the transmissibility of the upper and lower aquifers ranges from 50,000 to 100,000 gallons per day per foot and indicate that nearly 200 gpm (gallons per minute) leaks through the intervening aquiclude under nonpumping conditions. The object of the three recharge tests (tests 5, 6, and 7) was to observe the effects of induced recharge by varying conditions in the recharge channel. During the three recharge tests, 7 wells were pumped at a total rate averaging about 2,500 gpm. During test 5, inflow to the channel was shut off, and the water level in the channel was allowed to decline. Drawdowns measured during this test were used as a standard for comparison with drawdowns in tests 6 and 7. During test 6, the head in the recharge channel was maintained as constant as possible, and the inflow to the channel was measured. The rate of induced recharge, as indicated by the measured inflow, averaged about 300 gpm. Between tests 6 and 7, the area of the channel was increased from 27,000 to 143,000 square feet. During test 7, the head in the channel was again maintained as constant as possible, but the inflow to the larger channel increased to about 600 gpm. The principal effect of induced recharge on the two aquifers was to reduce the amount and rate of drawdown. Therefore, where water levels and artesian pressures can be maintained at high stages, the result is lower pumping costs and increased rates of withdrawal during periods of peak demand.

  2. A new analytical solution solved by triple series equations method for constant-head tests in confined aquifers

    NASA Astrophysics Data System (ADS)

    Chang, Ya-Chi; Yeh, Hund-Der

    2010-06-01

    The constant-head pumping tests are usually employed to determine the aquifer parameters and they can be performed in fully or partially penetrating wells. Generally, the Dirichlet condition is prescribed along the well screen and the Neumann type no-flow condition is specified over the unscreened part of the test well. The mathematical model describing the aquifer response to a constant-head test performed in a fully penetrating well can be easily solved by the conventional integral transform technique under the uniform Dirichlet-type condition along the rim of wellbore. However, the boundary condition for a test well with partial penetration should be considered as a mixed-type condition. This mixed boundary value problem in a confined aquifer system of infinite radial extent and finite vertical extent is solved by the Laplace and finite Fourier transforms in conjunction with the triple series equations method. This approach provides analytical results for the drawdown in a partially penetrating well for arbitrary location of the well screen in a finite thickness aquifer. The semi-analytical solutions are particularly useful for the practical applications from the computational point of view.

  3. Delineation of Areas Contributing Water to the Dry Brook Public-Supply Well, South Hadley, Massachusetts

    USGS Publications Warehouse

    Garabedian, Stephen P.; Stone, Janet Radway

    2004-01-01

    Areas contributing water to the Dry Brook public-supply well in South Hadley, Massachusetts, were delineated with a numerical ground-water-flow model that is based on geologic and hydrologic information for the confined sand and gravel aquifer pumped by the supply well. The study area is along the Connecticut River in central Massachusetts, about 12 miles north of Springfield, Massachusetts. Geologic units in the study area consist of Mesozoic-aged sedimentary and igneous bedrock, late-Pleistocene glaciolacustrine sediments, and recent alluvial deposits of the Connecticut River flood plain. Dry Brook Hill, immediately south of the supply well, is a large subaqueous lacustrine fan and delta formed during the last glacial retreat by sediment deposition into glacial Lake Hitchcock from a meltwater tunnel that was likely near where the Connecticut River cuts through the Holyoke Range. The sediments that compose the aquifer grade from very coarse sand and gravel along the northern flank of the hill, to medium sands in the body of the hill, and to finer-grained sediments along the southern flank of the hill. The interbedded and overlapping fine-grained lacustrine sediments associated with Dry Brook Hill include varved silt and clay deposits. These fine-grained sediments form a confining bed above the coarse-grained aquifer at the supply well and partially extend under the Connecticut River adjacent to the supply well. Ground-water flow in the aquifer supplying water to Dry Brook well was simulated with the U.S. Geological Survey ground-water-flow modeling code MODFLOW. The Dry Brook aquifer model was calibrated to drawdown data collected from 8 observation wells during an aquifer test conducted by pumping the supply well for 10 days at a rate of 122.2 cubic feet per minute (ft3/min; 914 gallons per minute) and to water levels collected from observation wells across the study area. Generally, the largest hydraulic conductivity values used in the model were in the sand and gravel aquifer near the Dry Brook well, which is consistent with the geologic information. Results of aquifer-test simulation indicated that spatially variable aquifer hydraulic properties and boundary conditions affected heads and ground-water flow near the well. A comparison and analysis of water-level fluctuations in study area wells to fluctuations in the Connecticut River indicated a hydraulic connection of the aquifer with the river, which is also consistent with geologic information. Simulated ground-water levels indicated that most ground water in the study area flowed toward and discharged to the Connecticut River and the Dry Brook well. Small amounts of ground water also discharged to smaller streams (Dry Brook and Bachelor Brook) in the study area. Areas contributing water to the well were delineated with the MODPATH particle-tracking routine. Results of the contributing-area analysis indicated that the greatest sources of water to the well were recharge in the Dry Brook Hill area and infiltration of Connecticut River water in an area beyond the extent of the confining bed where the aquifer is in hydraulic connection with the river. The amount of water entering the Dry Brook well from recharge dominated at a lower pumping rate (40.0 ft3/min); about 90 percent of the pumped water originated from recharge and boundary flow, and infiltration from the Connecticut River supplied the remaining 10 percent. At a high pumping rate (122.2 ft3/min), however, about half of the water pumped from the Dry Brook well originated from recharge and boundary flow (49 percent), and half originated from infiltration of water from the Connecticut River (51 percent). Results of a sensitivity analysis of the extent of areas contributing water to the Dry Brook well when pumped at 122.2 ft3/min indicated that the size of these areas did not substantially change when aquifer properties were varied. In contrast, however, the size of these areas changed most when the recharge

  4. Machine learning algorithms for modeling groundwater level changes in agricultural regions of the U.S.

    DOE PAGES

    Sahoo, S.; Russo, T. A.; Elliott, J.; ...

    2017-05-13

    Climate, groundwater extraction, and surface water flows have complex nonlinear relationships with groundwater level in agricultural regions. To better understand the relative importance of each driver and predict groundwater level change, we develop a new ensemble modeling framework based on spectral analysis, machine learning, and uncertainty analysis, as an alternative to complex and computationally expensive physical models. We apply and evaluate this new approach in the context of two aquifer systems supporting agricultural production in the United States: the High Plains aquifer (HPA) and the Mississippi River Valley alluvial aquifer (MRVA). We select input data sets by using a combinationmore » of mutual information, genetic algorithms, and lag analysis, and then use the selected data sets in a Multilayer Perceptron network architecture to simulate seasonal groundwater level change. As expected, model results suggest that irrigation demand has the highest influence on groundwater level change for a majority of the wells. The subset of groundwater observations not used in model training or cross-validation correlates strongly (R > 0.8) with model results for 88 and 83% of the wells in the HPA and MRVA, respectively. In both aquifer systems, the error in the modeled cumulative groundwater level change during testing (2003-2012) was less than 2 m over a majority of the area. Here, we conclude that our modeling framework can serve as an alternative approach to simulating groundwater level change and water availability, especially in regions where subsurface properties are unknown.« less

  5. Machine learning algorithms for modeling groundwater level changes in agricultural regions of the U.S.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sahoo, S.; Russo, T. A.; Elliott, J.

    Climate, groundwater extraction, and surface water flows have complex nonlinear relationships with groundwater level in agricultural regions. To better understand the relative importance of each driver and predict groundwater level change, we develop a new ensemble modeling framework based on spectral analysis, machine learning, and uncertainty analysis, as an alternative to complex and computationally expensive physical models. We apply and evaluate this new approach in the context of two aquifer systems supporting agricultural production in the United States: the High Plains aquifer (HPA) and the Mississippi River Valley alluvial aquifer (MRVA). We select input data sets by using a combinationmore » of mutual information, genetic algorithms, and lag analysis, and then use the selected data sets in a Multilayer Perceptron network architecture to simulate seasonal groundwater level change. As expected, model results suggest that irrigation demand has the highest influence on groundwater level change for a majority of the wells. The subset of groundwater observations not used in model training or cross-validation correlates strongly (R > 0.8) with model results for 88 and 83% of the wells in the HPA and MRVA, respectively. In both aquifer systems, the error in the modeled cumulative groundwater level change during testing (2003-2012) was less than 2 m over a majority of the area. Here, we conclude that our modeling framework can serve as an alternative approach to simulating groundwater level change and water availability, especially in regions where subsurface properties are unknown.« less

  6. Cross-well slug testing in unconfined aquifers: A case study from the Sleepers River Watershed, Vermont

    USGS Publications Warehouse

    Belitz, K.; Dripps, W.

    1999-01-01

    Normally, slug test measurements are limited to the well in which the water level is perturbed. Consequently, it is often difficult to obtain reliable estimates of hydraulic properties, particularly if the aquifer is anisotropic or if there is a wellbore skin. In this investigation, we use partially penetrating stress and observation wells to evaluate specific storage, radial hydraulic conductivity and anisotropy of the aquifer, and the hydraulic conductivity of the borehole skin. The study site is located in the W9 subbasin of the Sleepers River Research Watershed, Vermont. At the site, ~3 m of saturated till are partially penetrated by a stress well located in the center of the unconfined aquifer and six observation wells located above, below, and at the depth of the stress well at radial distances of 1.2 and 2.4 m. The observation wells were shut in with inflatable packers. The semianalytical solution of Butler (1995) was used to conduct a sensitivity analysis and to interpret slug test results. The sensitivity analysis indicates that the response of the stress well is primarily sensitive to radial hydraulic conductivity, less sensitive to anisotropy and the conductivity of the borehole skin, and nearly insensitive to specific storage. In contrast, the responses of the observation wells are sensitive to all four parameters. Interpretation of the field data was facilitated by generating type curves in a manner analogous to the method of Cooper et al. (1967). Because the value of radial hydraulic conductivity is obtained from a match point, the number of unknowns is reduced to three. The estimated values of radial hydraulic conductivity and specific storage are comparable to those derived from the methods of Bouwer and Rice (1976) and Cooper et al. (1967). The values and skin conductivity, however, could not have been obtained without the use of observation wells.Normally, slug test measurements are limited to the well in which the water level is perturbed. Consequently, it is often difficult to obtain reliable estimates of hydraulic properties, particularly if the aquifer is anisotropic or if there is a wellbore skin. In this investigation, we use partially penetrating stress and observation wells to evaluate specific storage, radial hydraulic conductivity and anisotropy of the aquifer, and the hydraulic conductivity of the borehole skin. The study site is located in the W9 subbasin of the Sleepers River Research Watershed, Vermont. At the site, approximately 3 m of saturated till are partially penetrated by a stress well located in the center of the unconfined aquifer and six observation wells located above, below, and at the depth of the stress well at radial distances of 1.2 and 2.4 m. The observation wells were shut in with inflatable packers. The semianalytical solution of Buffer (1995) was used to conduct a sensitivity analysis and to interpret slug test results. The sensitivity analysis indicates that the response of the stress well is primarily sensitive to radial hydraulic conductivity, less sensitive to anisotropy and the conductivity of the borehole skin, and nearly insensitive to specific storage. In contrast, the responses of the observation wells are sensitive to all four parameters. Interpretation of the field data was facilitated by generating type curves in a manner analogous to the method of Cooper et al. (1967). Because the value of radial hydraulic conductivity is obtained from a match point, the number of unknowns is reduced to three. The estimated values of radial hydraulic conductivity and specific storage are comparable to those derived from the methods of Bouwer and Rice (1976) and Cooper et al. (1967). The values and skin conductivity, however, could not have been obtained without the use of observation wells.

  7. Comparing flowmeter, aquifer test, and surface nuclear magnetic resonance data in Central Nebraska

    NASA Astrophysics Data System (ADS)

    Irons, T.; Abraham, J. D.; Cannia, J. C.; Steele, G.; Hobza, C. M.; Li, Y.; McKenna, J. R.

    2011-12-01

    Traditionally the only means of estimating the hydraulic properties of aquifers has involved drilling boreholes. The logistical and economic requirements of aquifer tests has limited the ability of hydrologists to construct the detailed groundwater models needed for resource management. As such, water policy decisions are often based on sparse aquifer tests combined with geologic interpretation and extrapolation. When dealing with complicated groundwater systems these extrapolations are often not accurate at the scale required to characterize the groundwater system, and additional information is needed to make better informed resource decisions. Surface nuclear magnetic resonance (SNMR) is a geophysical technique which allows for non-invasive estimates of hydraulic permeability and transmissivity. Protons in a volume of liquid water form a weak bulk magnetic moment as they align and precess about the earth's magnetic field. This moment is too small to be measured directly but may be observed by tipping it away from equilibrium using radio-frequency pulses oscillating at the same frequency as its precession (the Larmor frequency). After a short tipping pulse, the moment continues to precess around the static field, although at a tipped angle, slowly returning to its equilibrium state. The decay of these spinning magnetic moments can be observed inductively using loops of wire on the surface of the earth. In the simplest experiment a time series is recorded after a single tipping pulse. By varying the strength of the tipping pulse, different regions of the subsurface can be probed. The amplitude of the signal is directly proportional to the amount of water in the investigated volume. The decay rate of the signal is related to pore geometry and interconnectivity and can be used to estimate hydraulic conductivity. However, this relationship cannot be universally defined as it is affected by additional factors including the mineralogy of the host rock and homogeneity of the earth's magnetic field. This necessitates locally calibrating the SNMR data against aquifer tests in order to derive a relation of the SNMR data to the local aquifers. After calibration, additional SNMR data can be used at sites with the same aquifer units to produce estimates of hydraulic properties. To test this methodology, SNMR, aquifer tests and flowmeter measurements were conducted at two sites within the High Plains Aquifer in Central Nebraska. A novel compressive inversion scheme was developed that simultaneously processes the entire SNMR dataset and accounts for electrical conductivity. The inverted porosity and decay times were then regressed against the aquifer and flowmeter tests to derive local calibration coefficients. Using this calibration, the SNMR derived hydraulic conductivity estimates were in good agreement with the aquifer test-derived estimates. Since the same calibration was appropriate at both sites, SNMR data can now be collected at additional sites in the area and used to estimate hydraulic properties.

  8. Plan of study for the northern Midwest regional aquifer-system analysis

    USGS Publications Warehouse

    Steinhilber, W.L.; Young, H.L.

    1979-01-01

    Sedimentary rocks of Cambrian and Ordovician age form a major aquifer system in most of Wisconsin and Iowa, northern Illinois, northwestern Indiana, southeastern Minnesota, and northern Missouri. Many metropolitan areas depend on the aquifer for all or part of their water supplies. Declines in potentiometric head have been large in the most heavily pumped areas, most notably Chicago, Milwaukee-Waukesha, Minneapolis-St. Paul, and Des Moines. A thorough understanding of the aquifer system is needed for sound management decisions. Thus, a 4-year study of the aquifer, beginning in October 1978, is included in the U.S. Geological Survey 's program of Regional Aquifer-System Analysis. The study will evaluate the aquifer 's water-supply potential, describe its water quality, and, through computer models of the ground-water flow system, provide the means to evaluate regional aquifer response to different patterns of ground-water development. This report describes the objectives, work plan, and organization of this study. (Woodard-USGS)

  9. AQUIFER TESTING AND REBOUND STUDY IN SUPPORT OF THE 100-H DEEP CHROMIUM INVESTIGATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SMOOT JL

    2010-11-05

    The 100-HR-3 Groundwater Operable Unit (OU) second Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) 5-year review (DOEIRL-2006-20, The Second CERCLA Five-Year Review Report for the Hanford Site) set a milestone to conduct an investigation of deep hexavalent chromium contamination in the sediments of the Ringold upper mud (RUM) unit, which underlies the unconfined aquifer in the 100-H Area. The 5-year review noted that groundwater samples from one deep well extending below the aquitard (i.e., RUM) exceeded both the groundwater standard of 48 parts per billion (ppb) (Ecology Publication 94-06, Model Toxics Control Act Cleanup Statute and Regulation)more » and the federal drinking water standard of 100 {mu}g/L for hexavalent chromium. The extent of hexavalent chromium contamination in this zone is not well understood. Action 12-1 from the 5-year review is to perform additional characterization of the aquifer below the initial aquitard. Field characterization and aquifer testing were performed in the Hanford Site's 100-H Area to address this milestone. The aquifer tests were conducted to gather data to answer several fundamental questions regarding the presence of the hexavalent chromium in the deep sediments of the RUM and to determine the extent and magnitude of deeper contamination. The pumping tests were performed in accordance with the Description of Work for Aquifer Testing in Support of the 100-H Deep Chromium Investigation (SGW-41302). The specific objectives for the series of tests were as follows: (1) Evaluate the sustainable production of the subject wells using step-drawdown and constant-rate pumping tests. (2) Collect water-level data to evaluate the degree of hydraulic connection between the RUM and the unconfined (upper) aquifer (natural or induced along the well casing). (3) Evaluate the hydraulic properties of a confined permeable layer within the RUM.; (4) Collect time-series groundwater samples during testing to evaluate the extent and persistence of hexavalent chromium in the deeper zones. Use data collected to refine the current conceptual model for the 100-H Area unconfined aquifer and the RUM in this area. (5) Evaluate the concentration 'rebound' in the unconfined aquifer of hexavalent chromium and the contaminants of concern during shutdown of the extraction wells. Measure co-contaminants at the beginning, middle, and end of each pumping test. The RUM is generally considered an aquitard in the 100-HR-3 OU; however, several water-bearing sand layers are present that are confined within the RUM. The current hydrogeologic model for the 100-H Area aquifer system portrays the RUM as an aquitard layer that underlies the unconfined aquifer, which may contain permeable zones, stringers, or layers. These permeable zones may provide pathways for chromium to migrate deeper into the RUM under certain hydrogeologic conditions. One condition may be the discharge of large volumes of cooling water that occurred near the former H Reactor, which caused a mound of groundwater to form 4.9 to 10.1 m (16 to 33 ft) above the natural water table. The cooling water reportedly contained 1 to 2 mglL of hexavalent chromium for corrosion prevention. Three alternate hypotheses for the introduction of hexavalent chromium into the RUM are as follows: (1) Local groundwater with higher concentrations of hexavalent chromium originating from reactor operations at H Reactor was driven by high heads from groundwater mounding in the unconfined aquifer into the RUM via permeable pathways in the upper surface of the RUM. (2) Local groundwater with hexavalent chromium was introduced from the unconfined aquifer via well boreholes, either during drilling or as a result of poor well construction, allowing hydraulic communication between the unconfined aquifer and the RUM. (3) Hexavalent chromium migrated across the Hom area within the more permeable zones of the RUM. The three wells used for the aquifer pumping tests (199-H3-2C, 199-H4-12C, and 199-H4-15CS) exhibit hexavalent chromium contamination in confined aquifer groundwater that may be the result of one of the mechanisms described above. The purpose of the aquifer testing was to gather data to help refine the conceptual model for the source of deep contamination, examine the potential hydraulic connection between the RUM and the unconfined aquifer, evaluate the hydraulic properties of a confined layer within the RUM, and indicate the extent of hexavalent chromium contamination in the RUM. The results of this study, in conjunction with the recent Hom area investigation (DOE/RL-2008-42, Hydrogeological Summary Report for 600 Area Between 100-D and 100-H for the 100-HR-3 Groundwater Operable Unit), suggest that the first hypothesis is the most reasonable explanation. The results indicate persistent chromium concentrations over the duration of the tests, suggesting a large-scale emplacement of chromium.« less

  10. Effect of the Cedar River on the quality of the ground-water supply for Cedar Rapids, Iowa

    USGS Publications Warehouse

    Schulmeyer, P.M.

    1995-01-01

    Above-normal streamflow and precipitation during the study could have increased the effect the river had on the alluvial aquifer and on the possibility of contamination by a pathogen. Microscopic particulate analysis of 29 samples found no Giardia cysts or Crytosporidium oocysts in water collected from municipal wells. Data also indicate that the aquifer is filtering out large numbers of algae, diatoms, rotifers, and nematodes as well as filtering out Cryptosporidium, Giardia, and other protozoa. The number of algae, diatoms, rotifers, protozoa, and vegetative debris for selected municipal wells tested showed at least a reduction to 1 per 1,000 of the number found in the river. A relative risk factor and a log-reduction rate were determined for the aquifer in the vicinity of selected wells. One municipal well had a high-risk factor, three other wells had a moderate-risk factor, and four wells had a low-risk factor. The filtering efficiency of the aquifer is equivalent to a 3 log-reduction rate or 99.99-percent reduction in particulates.

  11. Monitoring-well installation, slug testing, and groundwater quality for selected sites in South Park, Park County, Colorado, 2013

    USGS Publications Warehouse

    Arnold, Larry R. Rick

    2015-01-01

    During May–June, 2013, the U.S. Geological Survey, in cooperation with Park County, Colorado, drilled and installed four groundwater monitoring wells in areas identified as needing new wells to provide adequate spatial coverage for monitoring water quality in the South Park basin. Lithologic logs and well-construction reports were prepared for each well, and wells were developed after drilling to remove mud and foreign material to provide for good hydraulic connection between the well and aquifer. Slug tests were performed to estimate hydraulic-conductivity values for aquifer materials in the screened interval of each well, and groundwater samples were collected from each well for analysis of major inorganic constituents, trace metals, nutrients, dissolved organic carbon, volatile organic compounds, ethane, methane, and radon. Documentation of lithologic logs, well construction, well development, slug testing, and groundwater sampling are presented in this report.

  12. Concentration history during pumping from a leaky aquifer with stratified initial concentration

    USGS Publications Warehouse

    Goode, Daniel J.; Hsieh, Paul A.; Shapiro, Allen M.; Wood, Warren W.; Kraemer, Thomas F.

    1993-01-01

    Analytical and numerical solutions are employed to examine the concentration history of a dissolved substance in water pumped from a leaky aquifer. Many aquifer systems are characterized by stratification, for example, a sandy layer overlain by a clay layer. To obtain information about separate hydrogeologic units, aquifer pumping tests are often conducted with a well penetrating only one of the layers. When the initial concentration distribution is also stratified (the concentration varies with elevation only), the concentration breakthrough in the pumped well may be interpreted to provide information on aquifer hydraulic and transport properties. To facilitate this interpretation, we present some simple analytical and numerical solutions for limiting cases and illustrate their application to a fractured bedrock/glacial drift aquifer system where the solute of interest is dissolved radon gas. In addition to qualitative information on water source, this method may yield estimates of effective porosity and saturated thickness (or fracture transport aperture) from a single-hole test. Little information about dispersivity is obtained because the measured concentration is not significantly affected by dispersion in the aquifer.

  13. Lithology identification of aquifers from geophysical well logs and fuzzy logic analysis: Shui-Lin Area, Taiwan

    NASA Astrophysics Data System (ADS)

    Hsieh, Bieng-Zih; Lewis, Charles; Lin, Zsay-Shing

    2005-04-01

    The purpose of this study is to construct a fuzzy lithology system from well logs to identify formation lithology of a groundwater aquifer system in order to better apply conventional well logging interpretation in hydro-geologic studies because well log responses of aquifers are sometimes different from those of conventional oil and gas reservoirs. The input variables for this system are the gamma-ray log reading, the separation between the spherically focused resistivity and the deep very-enhanced resistivity curves, and the borehole compensated sonic log reading. The output variable is groundwater formation lithology. All linguistic variables are based on five linguistic terms with a trapezoidal membership function. In this study, 50 data sets are clustered into 40 training sets and 10 testing sets for constructing the fuzzy lithology system and validating the ability of system prediction, respectively. The rule-based database containing 12 fuzzy lithology rules is developed from the training data sets, and the rule strength is weighted. A Madani inference system and the bisector of area defuzzification method are used for fuzzy inference and defuzzification. The success of training performance and the prediction ability were both 90%, with the calculated correlation of training and testing equal to 0.925 and 0.928, respectively. Well logs and core data from a clastic aquifer (depths 100-198 m) in the Shui-Lin area of west-central Taiwan are used for testing the system's construction. Comparison of results from core analysis, well logging and the fuzzy lithology system indicates that even though the well logging method can easily define a permeable sand formation, distinguishing between silts and sands and determining grain size variation in sands is more subjective. These shortcomings can be improved by a fuzzy lithology system that is able to yield more objective decisions than some conventional methods of log interpretation.

  14. Aquifer thermal-energy-storage modeling

    NASA Astrophysics Data System (ADS)

    Schaetzle, W. J.; Lecroy, J. E.

    1982-09-01

    A model aquifer was constructed to simulate the operation of a full size aquifer. Instrumentation to evaluate the water flow and thermal energy storage was installed in the system. Numerous runs injecting warm water into a preconditioned uniform aquifer were made. Energy recoveries were evaluated and agree with comparisons of other limited available data. The model aquifer is simulated in a swimming pool, 18 ft by 4 ft, which was filled with sand. Temperature probes were installed in the system. A 2 ft thick aquifer is confined by two layers of polyethylene. Both the aquifer and overburden are sand. Four well configurations are available. The system description and original tests, including energy recovery, are described.

  15. GeoChip-based analysis of microbial functional gene diversity in a landfill leachate-contaminated aquifer

    USGS Publications Warehouse

    Lu, Zhenmei; He, Zhili; Parisi, Victoria A.; Kang, Sanghoon; Deng, Ye; Van Nostrand, Joy D.; Masoner, Jason R.; Cozzarelli, Isabelle M.; Suflita, Joseph M.; Zhou, Jizhong

    2012-01-01

    The functional gene diversity and structure of microbial communities in a shallow landfill leachate-contaminated aquifer were assessed using a comprehensive functional gene array (GeoChip 3.0). Water samples were obtained from eight wells at the same aquifer depth immediately below a municipal landfill or along the predominant downgradient groundwater flowpath. Functional gene richness and diversity immediately below the landfill and the closest well were considerably lower than those in downgradient wells. Mantel tests and canonical correspondence analysis (CCA) suggested that various geochemical parameters had a significant impact on the subsurface microbial community structure. That is, leachate from the unlined landfill impacted the diversity, composition, structure, and functional potential of groundwater microbial communities as a function of groundwater pH, and concentrations of sulfate, ammonia, and dissolved organic carbon (DOC). Historical geochemical records indicate that all sampled wells chronically received leachate, and the increase in microbial diversity as a function of distance from the landfill is consistent with mitigation of the impact of leachate on the groundwater system by natural attenuation mechanisms.

  16. Geophysical Assessment of Groundwater Potential: A Case Study from Mian Channu Area, Pakistan.

    PubMed

    Hasan, Muhammad; Shang, Yanjun; Akhter, Gulraiz; Jin, Weijun

    2017-11-17

    An integrated study using geophysical method in combination with pumping tests and geochemical method was carried out to delineate groundwater potential zones in Mian Channu area of Pakistan. Vertical electrical soundings (VES) using Schlumberger configuration with maximum current electrode spacing (AB/2 = 200 m) were conducted at 50 stations and 10 pumping tests at borehole sites were performed in close proximity to 10 of the VES stations. The aim of this study is to establish a correlation between the hydraulic parameters obtained from geophysical method and pumping tests so that the aquifer potential can be estimated from the geoelectrical surface measurements where no pumping tests exist. The aquifer parameters, namely, transmissivity and hydraulic conductivity were estimated from Dar Zarrouyk parameters by interpreting the layer parameters such as true resistivities and thicknesses. Geoelectrical succession of five-layer strata (i.e., topsoil, clay, clay sand, sand, and sand gravel) with sand as a dominant lithology was found in the study area. Physicochemical parameters interpreted by World Health Organization and Food and Agriculture Organization were well correlated with the aquifer parameters obtained by geoelectrical method and pumping tests. The aquifer potential zones identified by modeled resistivity, Dar Zarrouk parameters, pumped aquifer parameters, and physicochemical parameters reveal that sand and gravel sand with high values of transmissivity and hydraulic conductivity are highly promising water bearing layers in northwest of the study area. Strong correlation between estimated and pumped aquifer parameters suggest that, in case of sparse well data, geophysical technique is useful to estimate the hydraulic potential of the aquifer with varying lithology. © 2017, National Ground Water Association.

  17. Heat tracer test in an alluvial aquifer: Field experiment and inverse modelling

    NASA Astrophysics Data System (ADS)

    Klepikova, Maria; Wildemeersch, Samuel; Hermans, Thomas; Jamin, Pierre; Orban, Philippe; Nguyen, Frédéric; Brouyère, Serge; Dassargues, Alain

    2016-09-01

    Using heat as an active tracer for aquifer characterization is a topic of increasing interest. In this study, we investigate the potential of using heat tracer tests for characterization of a shallow alluvial aquifer. A thermal tracer test was conducted in the alluvial aquifer of the Meuse River, Belgium. The tracing experiment consisted in simultaneously injecting heated water and a dye tracer in an injection well and monitoring the evolution of groundwater temperature and tracer concentration in the pumping well and in measurement intervals. To get insights in the 3D characteristics of the heat transport mechanisms, temperature data from a large number of observation wells closely spaced along three transects were used. Temperature breakthrough curves in observation wells are contrasted with what would be expected in an ideal layered aquifer. They reveal strongly unequal lateral and vertical components of the transport mechanisms. The observed complex behavior of the heat plume is explained by the groundwater flow gradient on the site and heterogeneities in the hydraulic conductivity field. Moreover, due to high injection temperatures during the field experiment a temperature-induced fluid density effect on heat transport occurred. By using a flow and heat transport numerical model with variable density coupled with a pilot point approach for inversion of the hydraulic conductivity field, the main preferential flow paths were delineated. The successful application of a field heat tracer test at this site suggests that heat tracer tests is a promising approach to image hydraulic conductivity field. This methodology could be applied in aquifer thermal energy storage (ATES) projects for assessing future efficiency that is strongly linked to the hydraulic conductivity variability in the considered aquifer.

  18. Aquifer Thermal Energy Storage in the US

    NASA Astrophysics Data System (ADS)

    Kannberg, L. D.

    1985-06-01

    DOE has funded investigation of Aquifer Thermal Energy Storage (ATES) since 1975. The scope of the ATES investigation has encompassed numerical modeling, field testing, economic analyses, and evaluation of institutional issues. ATES has received the bulk of the attention because of its widespread potential in the US. US efforts are now concentrated on a high temperature (up to 150C) ATES field test on the St. Paul campus of the University of Minnesota. Four short-term test cycles and the first of two long-term test cycles have been completed at this site. Utilization of chill ATES to meet summer air conditioning demands has been monitored at two operating sites in Tuscaloosa, Alabama. The systems utilize a cooling tower to directly chill groundwater pumped from a water table aquifer for storage in the same aquifer. The first of the two systems has exhibited relatively poor performance. More comprehensive monitoring has recently been undertaken at another site.

  19. BIODEGRADATION OF AROMATIC HYDROCARBONS BY AQUIFER MICROORGANISMS UNDER DENITRIFYING CONDITIONS

    EPA Science Inventory

    A series of laboratory tests were conducted to evaluate whether denitrification would be a suitable alternative for biorestoration of an aquifer contaminated with JP-4 jet fuel. Microcosms were prepared from both uncontaminated and contaminated-aquifer material from the site, in ...

  20. Use of Geophysical and Remote Sensing Data for Assessment of Aquifer Depletion and Related Land Deformation

    NASA Astrophysics Data System (ADS)

    Othman, Abdullah; Sultan, Mohamed; Becker, Richard; Alsefry, Saleh; Alharbi, Talal; Gebremichael, Esayas; Alharbi, Hassan; Abdelmohsen, Karem

    2018-01-01

    An integrated approach [field, Interferometric Synthetic Aperture Radar (InSAR), hydrogeology, geodesy, and spatial analysis] was adopted to identify the nature, intensity, and spatial distribution of deformational features (sinkholes, fissures, differential settling) reported over fossil aquifers in arid lands, their controlling factors, and possible remedies. The Lower Mega Aquifer System (area 2 × 106 km2) in central and northern Arabia was used as a test site. Findings suggest that excessive groundwater extraction from the fossil aquifer is the main cause of deformation: (1) deformational features correlated spatially and/or temporally with increased agricultural development and groundwater extraction, and with a decline in water levels and groundwater storage (- 3.7 ± 0.6 km3/year); (2) earthquake events (years 1985-2016; magnitude 1-5) are largely (65% of reported earthquakes) shallow (1-5 km) and increased from 1 event/year in the early 1980s (extraction 1 km3/year), up to 13 events/year in the 1990s (average annual extraction > 6.4 km3). Results indicate that faults played a role in localizing deformation given that deformational sites and InSAR-based high subsidence rates (- 4 to - 15 mm/year) were largely found within, but not outside of, NW-SE-trending grabens bound by the Kahf fault system. Findings from the analysis of Gravity Recovery and Climate Experiment solutions indicate that sustainable extraction could be attained if groundwater extraction was reduced by 3.5-4 km3/year. This study provides replicable and cost-effective methodologies for optimum utilization of fossil aquifers and for minimizing deformation associated with their use.

  1. Geology, hydrology, and results of tracer testing in the Galena-Platteville aquifer at a waste-disposal site near Byron, Illinois

    USGS Publications Warehouse

    Kay, Robert T.; Yeskis, Douglas J.; Prinos, Scott T.; Morrow, William S.; Vendl, Mark

    1999-01-01

    A study was conducted by the U.S. Geological Survey and the U.S. Environmental Protection Agency of the geohydrology of the dolomite bedrock at a waste-disposal site near Byron, Illinois. The study was designed to identify and characterize the flow pathways through the bedrock aquifer beneath the site. The geologic units of concern at the site are the Glenwood Formation of the Ancell Group, and the Platteville and Galena Groups. These deposits compose the Galena-Platteville aquifer and the underlying Harmony Hill Shale semiconfining unit. The Galena-Platteville aquifer is an unconfined aquifer. Geophysical logging, water levels, and aquifer-test data indicate the presence of interconnected, hydraulically active fractures in the middle of the Galena-Platteville aquifer (the upper flow pathway), and a second set of hydraulically active fractures (the lower flow pathway). The lower flow pathway may be present through much of the site. Few hydraulically active fractures are present in the upper part of the aquifer near the center of the site, but appear to be more numerous in the upper part of the aquifer in the western and northeastern parts of the site. Water-level data obtained during the tracer test indicate that pumping effects were present near the pumped wells. Pumping effects may have been present at several wells located along directions of identified fracture orientation from the pumped well. The upper part of the aquifer did not appear to be hydraulically well connected to the flow pathways supplying water to the pumped well. Large background changes in water levels obscured the effects of pumping and prevented calculation of aquifer properties. The velocity of the bromide tracer through the lower flow pathway under the hydraulic gradient resulting from the pumping was about 152 feet per day. Solution of the Darcy velocity equation results in a calculated effective porosity for this interval of 3.5 percent, indicating hydraulic interconnection between the fractures and the aquifer matrix. Ground-water velocity through the lower flow pathway was calculated to be 15.4 feet per day under hydrostatic conditions.

  2. SIMULATIONS OF TWO-WELL TRACER TESTS IN STRATIFIED AQUIFERS AT THE CHALK RIVER AND THE MOBILE SITES

    EPA Science Inventory

    A simulation of two-well injection-withdrawal tracer tests in stratified granular aquifers is presented for two widely separated sites substantially different in terms of vertical distributions of hydraulic conductivity, well spacings, flow rates, test durations and tracer travel...

  3. A wetland aquifer interaction test

    NASA Astrophysics Data System (ADS)

    Wise, W. R.; Annable, M. D.; Walser, J. A. E.; Switt, R. S.; Shaw, D. T.

    2000-01-01

    An understanding of the hydraulic connectivity between an isolated wetland and its underlying groundwater is required to help assess the ecological impact that changes in the groundwater level may induce. Literature values for the hydraulic conductivity of peat vary up to ten orders of magnitude, indicating the absolute necessity of obtaining site-specific information. Horizontal and vertical variability in peat layers makes the process of extrapolating point-based measurements to predict system-level behavior difficult. By inducing or augmenting a flow up from the underlying aquifer into the wetland through a rapid lowering of wetland water level, the system-level hydraulic connectivity of a wetland to the groundwater may be directly measured. At a study site, a small, seasonally flooded depression mash wetland in Florida, the method and subsequent analysis yielded a value for the hydraulic resistance of the organic layer of 6 days, indicating a significant connection between the wetland and the aquifer.

  4. Multiscale characterization of a heterogeneous aquifer using an ASR operation.

    PubMed

    Pavelic, Paul; Dillon, Peter J; Simmons, Craig T

    2006-01-01

    Heterogeneity in the physical properties of an aquifer can significantly affect the viability of aquifer storage and recovery (ASR) by reducing the recoverable proportion of low-salinity water where the ambient ground water is brackish or saline. This study investigated the relationship between knowledge of heterogeneity and predictions of solute transport and recovery efficiency by combining permeability and ASR-based tracer testing with modeling. Multiscale permeability testing of a sandy limestone aquifer at an ASR trial site showed that small-scale core data give lower-bound estimates of aquifer hydraulic conductivity (K), intermediate-scale downhole flowmeter data offer valuable information on variations in K with depth, and large-scale pumping test data provide an integrated measure of the effective K that is useful to constrain ground water models. Chloride breakthrough and thermal profiling data measured during two cycles of ASR showed that the movement of injected water is predominantly within two stratigraphic layers identified from the flowmeter data. The behavior of the injectant was reasonably well simulated with a four-layer numerical model that required minimal calibration. Verification in the second cycle achieved acceptable results given the model's simplicity. Without accounting for the aquifer's layered structure, high precision could be achieved on either piezometer breakthrough or recovered water quality, but not both. This study demonstrates the merit of an integrated approach to characterizing aquifers targeted for ASR.

  5. Selected Hydrogeologic Data for the High Plains Aquifer in Southwestern Laramie County, Wyoming, 1931-2006

    USGS Publications Warehouse

    Hallberg, Laura L.; Mason, Jon P.

    2007-01-01

    The U.S. Geological Survey, in cooperation with the Wyoming State Engineer's Office, created a hydrogeologic database for southwestern Laramie County, Wyoming. The database contains records from 166 wells and test holes drilled during 1931-2006. Several types of information, including well construction; well or test hole locations; lithologic logs; gamma, neutron, spontaneous-potential, and single-point resistivity logs; water levels; and transmissivities and storativities estimated from aquifer tests, are available in the database. Most wells and test holes in the database have records containing information about construction, location, and lithology; 77 wells and test holes have geophysical logs; 70 wells have tabulated water-level data; and 60 wells have records of aquifer-test results.

  6. Pathogen and chemical transport in the karst limestone of the Biscayne aquifer: 1. Revised conceptualization of groundwater flow

    USGS Publications Warehouse

    Renken, Robert A.; Cunningham, Kevin J.; Shapiro, Allen M.; Harvey, Ronald W.; Zygnerski, Michael R.; Metge, David W.; Wacker, Michael A.

    2008-01-01

    The Biscayne aquifer is a highly transmissive karst limestone that serves as the sole source of drinking water to over two million residents in south Florida. The aquifer is characterized by eogenetic karst, where the most transmissive void space can be an interconnected, touching‐vug, biogenically influenced porosity of biogenic origin. Public supply wells in the aquifer are in close proximity to lakes established by surface mining. The mining of the limestone has occurred to the same depths as the production wells, which has raised concerns about pathogen and chemical transport from these surface water bodies. Hydraulic and forced gradient tracer tests were conducted to augment geologic and geophysical studies and to develop a hydrogeologic conceptual model of groundwater flow and chemical transport in the Biscayne aquifer. Geologic and geophysical data indicate multiple, areally extensive subhorizontal preferential flow zones of vuggy limestone separated by rock with a matrix pore system. The hydraulic response from an aquifer test suggests that the Biscayne aquifer behaves as a dual‐porosity medium; however, the results of the tracer test showed rapid transport similar to other types of karst. The tracer test and concurrent temperature logging revealed that only one of the touching‐vug flow zones dominates transport near the production wells. On the basis of the rising limb of the breakthrough curve, the dispersivity is estimated to be less than 3% of the tracer travel distance, which suggests that the fastest flow paths in the formation are likely to yield limited dilution of chemical constituents.

  7. Hydrologic and water-chemistry data from the Cretaceous-aquifers test well (BFT-2055), Beaufort County, South Carolina

    USGS Publications Warehouse

    Landmeyer, J.E.; Bradley, P.M.

    1998-01-01

    Test well BFT-2055 was drilled through the entire thickness of Coastal Plain sediments beneath central Hilton Head Island, South Carolina, and terminated in bedrock at a depth of 3833 feet. The well was drilled to evaluate the hydraulic properties of the Cretaceous formations beneath Hilton Head Island as a potential source of supplemental water to supplies currently withdrawn from the Upper Floridan aquifer. The intervals tested include sediments of the Cape Fear and Middendorf Formations. Results from aquifer tests indicate that the transmissivity of the formations screened ranges from 1300 to 3000 feet squared per day and an average hydraulic conductivity of about 15 feet per day. Formation-fluid pressure tests indicate that the potential exists for upward ground-water flow from higher fluid pressures in the deeper Cape Fear and Middendorf Formations to lower fluid pressures in the Black Creek Formation and shallower units. A flowmeter test indicated that greater than 75 percent of the natural, unpumped flow in the well is from the screened intervals no deeper than 3100 feet. Water-chemistry analyses indicate that the water sampled from the Middendorf and Cape Fear has about 1450 milligrams per liter dissolved solids, 310 to 1000 milligrams per liter sodium, and 144 to 1600 milligrams per liter chloride. Because these chloride concentrations would render water pumped from these aquifers as nonpotable, it is unlikely that these aquifers will be used as a supplemental source of water for island residents without some form of pretreatment. Similar chloride concentrations are present in some wells in the Upper Floridan aquifer adjacent to Port Royal Sound, and these chloride concentrations were the primary reason for drilling the test well in the Cretaceous formations as a possible source of more potable water.

  8. Potentiometric surfaces of the Arnold Engineering Development Complex Area, Arnold Air Force Base, Tennessee, May and September 2011

    USGS Publications Warehouse

    Haugh, Connor J.; Robinson, John A.

    2016-01-29

    During May 2011, when water levels were near seasonal highs, water-level data were collected from 374 monitoring wells; and during September 2011, when water levels were near seasonal lows, water-level data were collected from 376 monitoring wells. Potentiometric surfaces were mapped by contouring altitudes of water levels measured in wells completed in the shallow aquifer, the upper and lower parts of the Manchester aquifer, and the Fort Payne aquifer. Water levels are generally 2 to 14 feet lower in September compared to May. The potentiometric-surface maps for all aquifers indicate a groundwater depression at the J4 test cell. Similar groundwater depressions in the shallow and upper parts of the Manchester aquifer are within the main testing area at the Arnold Engineering Development Complex at dewatering facilities.

  9. Dual-Screened Vertical Circulation Wells for Groundwater Lowering in Unconfined Aquifers.

    PubMed

    Jin, Yulan; Holzbecher, Ekkehard; Sauter, Martin

    2016-01-01

    A new type of vertical circulation well (VCW) is used for groundwater dewatering at construction sites. This type of VCW consists of an abstraction screen in the upper part and an injection screen in the lower part of a borehole, whereby drawdown is achieved without net withdrawal of groundwater from the aquifer. The objective of this study is to evaluate the operation of such wells including the identification of relevant factors and parameters based on field data of a test site and comprehensive numerical simulations. The numerical model is able to delineate the drawdown of groundwater table, defined as free-surface, by coupling the arbitrary Lagrangian-Eulerian algorithm with the groundwater flow equation. Model validation is achieved by comparing the field observations with the model results. Eventually, the influences of selected well operation and aquifer parameters on drawdown and on the groundwater flow field are investigated by means of parameter sensitivity analysis. The results show that the drawdown is proportional to the flow rate, inversely proportional to the aquifer conductivity, and almost independent of the aquifer anisotropy in the direct vicinity of the well. The position of the abstraction screen has a stronger effect on drawdown than the position of the injection screen. The streamline pattern depends strongly on the separation length of the screens and on the aquifer anisotropy, but not on the flow rate and the horizontal hydraulic conductivity. © 2015, National Ground Water Association.

  10. Using solute and heat tracers for aquifer characterization in a strongly heterogeneous alluvial aquifer

    NASA Astrophysics Data System (ADS)

    Sarris, Theo S.; Close, Murray; Abraham, Phillip

    2018-03-01

    A test using Rhodamine WT and heat as tracers, conducted over a 78 day period in a strongly heterogeneous alluvial aquifer, was used to evaluate the utility of the combined observation dataset for aquifer characterization. A highly parameterized model was inverted, with concentration and temperature time-series as calibration targets. Groundwater heads recorded during the experiment were boundary dependent and were ignored during the inversion process. The inverted model produced a high resolution depiction of the hydraulic conductivity and porosity fields. Statistical properties of these fields are in very good agreement with estimates from previous studies at the site. Spatially distributed sensitivity analysis suggests that both solute and heat transport were most sensitive to the hydraulic conductivity and porosity fields and less sensitive to dispersivity and thermal distribution factor, with sensitivity to porosity greatly reducing outside the monitored area. The issues of model over-parameterization and non-uniqueness are addressed through identifiability analysis. Longitudinal dispersivity and thermal distribution factor are highly identifiable, however spatially distributed parameters are only identifiable near the injection point. Temperature related density effects became observable for both heat and solute, as the temperature anomaly increased above 12 degrees centigrade, and affected down gradient propagation. Finally we demonstrate that high frequency and spatially dense temperature data cannot inform a dual porosity model in the absence of frequent solute concentration measurements.

  11. Conceptual and numerical models of the glacial aquifer system north of Aberdeen, South Dakota

    USGS Publications Warehouse

    Marini, Katrina A.; Hoogestraat, Galen K.; Aurand, Katherine R.; Putnam, Larry D.

    2012-01-01

    This U.S. Geological Survey report documents a conceptual and numerical model of the glacial aquifer system north of Aberdeen, South Dakota, that can be used to evaluate and manage the city of Aberdeen's water resources. The glacial aquifer system in the model area includes the Elm, Middle James, and Deep James aquifers, with intervening confining units composed of glacial till. The Elm aquifer ranged in thickness from less than 1 to about 95 feet (ft), with an average thickness of about 24 ft; the Middle James aquifer ranged in thickness from less than 1 to 91 ft, with an average thickness of 13 ft; and the Deep James aquifer ranged in thickness from less than 1 to 165 ft, with an average thickness of 23 ft. The confining units between the aquifers consisted of glacial till and ranged in thickness from 0 to 280 ft. The general direction of groundwater flow in the Elm aquifer in the model area was from northwest to southeast following the topography. Groundwater flow in the Middle James aquifer was to the southeast. Sparse data indicated a fairly flat potentiometric surface for the Deep James aquifer. Horizontal hydraulic conductivity for the Elm aquifer determined from aquifer tests ranged from 97 to 418 feet per day (ft/d), and a confined storage coefficient was determined to be 2.4x10-5. Estimates of the vertical hydraulic conductivity of the sediments separating the Elm River from the Elm aquifer, determined from the analysis of temperature gradients, ranged from 0.14 to 2.48 ft/d. Average annual precipitation in the model area was 19.6 inches per year (in/yr), and agriculture was the primary land use. Recharge to the Elm aquifer was by infiltration of precipitation through overlying outwash, lake sediments, and glacial till. The annual recharge for the model area, calculated by using a soil-water-balance method for water year (WY) 1975-2009, ranged from 0.028 inch in WY 1980 to 4.52 inches in WY 1986, with a mean of 1.56 inches. The annual potential evapotranspiration, calculated in soil-water-balance analysis, ranged from 21.8 inches in WY 1983 to 27.0 inches in WY 1985, with a mean of 24.6 inches. Water use from the glacial aquifer system primarily was from the Elm aquifer for irrigation, municipal, and suburban water supplies, and the annual rate ranged from 1.0 to 2.4 cubic feet per second (ft3/s). The MODFLOW-2005 numerical model represented the Elm aquifer, the Middle James aquifer, and the Deep James aquifer with model layers 1-3 respectively separated by confining layers 1-2 respectively. Groundwater flow was simulated with 75 stress periods beginning October 1, 1974, and ending September 30, 2009. Model grid spacing was 200 by 200 ft and boundaries were represented by specified-head boundaries and no-flow boundaries. The model used parameter estimation that focused on minimizing the difference between 954 observed and simulated hydraulic heads for 135 wells. Calibrated mean horizontal hydraulic conductivity values for model layers 1-3 were 94, 41, and 30 ft/d respectively. Vertical hydraulic conductivity values for confining layers 1 and 2 were 0.0002 and 0.0003 ft/d, respectively. Calibrated specific yield for model layer 1was 0.1 and specific storage ranged from 0.0003 to 0.0005 per foot. Calibrated mean recharge rates ranged from 2.5 in/yr where glacial till thickness was less than 10 ft to 0.8 in/yr where glacial till thickness was greater than 30 ft. Calibrated mean annual evapotranspiration rate was 8.8 in/yr. Simulated net streamflow gain from model layer 1 was 3.1 ft3/s.

  12. Hydrogeology and ground-water flow in the Memphis and Fort Pillow aquifers in the Memphis area, Tennessee

    USGS Publications Warehouse

    Brahana, J.V.; Broshears, R.E.

    2001-01-01

    On the basis of known hydrogeology of the Memphis and Fort Pillow aquifers in the Memphis area, a three-layer, finite-difference numerical model was constructed and calibrated as the primary tool to refine understanding of flow in the aquifers. The model was calibrated and tested for accuracy in simulating measured heads for nine periods of transient flow from 1886-1985. Testing and sensitivity analyses indicated that the model accurately simulated observed heads areally as well as through time. The study indicates that the flow system is currently dominated by the distribution of pumping in relation to the distribution of areally variable confining units. Current withdrawal of about 200 million gallons per day has altered the prepumping flow paths, and effectively captured most of the water flowing through the aquifers. Ground-water flow is controlled by the altitude and location of sources of recharge and discharge, and by the hydraulic characteristics of the hydrogeologic units. Leakage between the Fort Pillow aquifer and Memphis aquifer, and between the Memphis aquifer and the water-table aquifers (alluvium and fluvial deposits) is a major component of the hydrologic budget. The study indicates that more than 50 percent of the water withdrawn from the Memphis aquifer in 1980 is derived from vertical leakage across confining units, and the leakage from the shallow aquifer (potential source of contamination) is not uniformly distributed. Simulated leakage was concentrated along the upper reaches of the Wolf and Loosahatchie Rivers, along the upper reaches of Nonconnah Creek, and the surficial aquifer of the Mississippi River alluvial plain. These simulations are supported by the geologic and geophysical evidence suggesting relatively thin or sandy confining units in these general locations. Because water from surficial aquifers is inferior in quality and more susceptible to contamination than water in the deeper aquifers, high rates of leakage to the Memphis aquifer may be cause for concern. A significant component of flow (12 percent) discharging from the Fort Pillow aquifer was calculated as upward leakage to the Memphis aquifer. This upward leakage was generally limited to areas near major pumping centers in the Memphis aquifer, where heads in the Memphis aquifer have been drawn significantly below heads in the Fort Pillow aquifer. Although the Fort Pillow aquifer is not capable of producing as much water as the Memphis aquifer for similar conditions, it is nonetheless a valuable resource throughout the area.

  13. Aquifer Characteristics Data Report for the Weldon Spring Site chemical plant/raffinate pits and vicinity properties for the Weldon Spring Site Remedial Action Project, Weldon Spring, Missouri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-11-01

    This report describes the procedures and methods used, and presents the results of physical testing performed, to characterize the hydraulic properties of the shallow Mississippian-Devonian aquifer beneath the Weldon Spring chemical plant, raffinate pits, and vicinity properties. The aquifer of concern is composed of saturated rocks of the Burlington-Keokuk Limestone which constitutes the upper portion of the Mississippian-Devonian aquifer. This aquifer is a heterogeneous anisotropic medium which can be described in terms of diffuse Darcian flow overlain by high porosity discrete flow zones and conduits. Average hydraulic conductivity for all wells tested is 9.6E-02 meters/day (3.1E-01 feet/day). High hydraulic conductivitymore » values are representative of discrete flow in the fractured and weathered zones in the upper Burlington-Keokuk Limestone. They indicate heterogeneities within the Mississippian-Devonian aquifer. Aquifer heterogeneity in the horizontal plane is believed to be randomly distributed and is a function of fracture spacing, solution voids, and preglacial weathering phenomena. Relatively high hydraulic conductivities in deeper portions of the aquifer are though to be due to the presence of widely spaced fractures. 44 refs., 27 figs., 9 tabs.« less

  14. Aquifer sensitivity to pesticide leaching: Testing a soils and hydrogeologic index method

    USGS Publications Warehouse

    Mehnert, E.; Keefer, D.A.; Dey, W.S.; Wehrmann, H.A.; Wilson, S.D.; Ray, C.

    2005-01-01

    For years, researchers have sought index and other methods to predict aquifer sensitivity and vulnerability to nonpoint pesticide contamination. In 1995, an index method and map were developed to define aquifer sensitivity to pesticide leaching based on a combination of soil and hydrogeologic factors. The soil factor incorporated three soil properties: hydraulic conductivity, amount of organic matter within individual soil layers, and drainage class. These properties were obtained from a digital soil association map. The hydrogeologic factor was depth to uppermost aquifer material. To test this index method, a shallow ground water monitoring well network was designed, installed, and sampled in Illinois. The monitoring wells had a median depth of 7.6 m and were located adjacent to corn and soybean fields where the only known sources of pesticides were those used in normal agricultural production. From September 1998 through February 2001, 159 monitoring wells were sampled for 14 pesticides but no pesticide metabolites. Samples were collected and analyzed to assess the distribution of pesticide occurrence across three units of aquifer sensitivity. Pesticides were detected in 18% of all samples and nearly uniformly from samples from the three units of aquifer sensitivity. The new index method did not predict pesticide occurrence because occurrence was not dependent on the combined soil and hydrogeologic factors. However, pesticide occurrence was dependent on the tested hydrogeologic factor and was three times higher in areas where the depth to the uppermost aquifer was <6 m than in areas where the depth to the uppermost aquifer was 6 to <15 m. Copyright ?? 2005 National Ground Water Association.

  15. Stochastic analysis of the efficiency of coupled hydraulic-physical barriers to contain solute plumes in highly heterogeneous aquifers

    NASA Astrophysics Data System (ADS)

    Pedretti, Daniele; Masetti, Marco; Beretta, Giovanni Pietro

    2017-10-01

    The expected long-term efficiency of vertical cutoff walls coupled to pump-and-treat technologies to contain solute plumes in highly heterogeneous aquifers was analyzed. A well-characterized case study in Italy, with a hydrogeological database of 471 results from hydraulic tests performed on the aquifer and the surrounding 2-km-long cement-bentonite (CB) walls, was used to build a conceptual model and assess a representative remediation site adopting coupled technologies. In the studied area, the aquifer hydraulic conductivity Ka [m/d] is log-normally distributed with mean E (Ya) = 0.32 , variance σYa2 = 6.36 (Ya = lnKa) and spatial correlation well described by an exponential isotropic variogram with integral scale less than 1/12 the domain size. The hardened CB wall's hydraulic conductivity, Kw [m/d], displayed strong scaling effects and a lognormal distribution with mean E (Yw) = - 3.43 and σYw2 = 0.53 (Yw =log10Kw). No spatial correlation of Kw was detected. Using this information, conservative transport was simulated across a CB wall in spatially correlated 1-D random Ya fields within a numerical Monte Carlo framework. Multiple scenarios representing different Kw values were tested. A continuous solute source with known concentration and deterministic drains' discharge rates were assumed. The efficiency of the confining system was measured by the probability of exceedance of concentration over a threshold (C∗) at a control section 10 years after the initial solute release. It was found that the stronger the aquifer heterogeneity, the higher the expected efficiency of the confinement system and the lower the likelihood of aquifer pollution. This behavior can be explained because, for the analyzed aquifer conditions, a lower Ka generates more pronounced drawdown in the water table in the proximity of the drain and consequently a higher advective flux towards the confined area, which counteracts diffusive fluxes across the walls. Thus, a higher σYa2 results in a larger amount of low Ka values in the proximity of the drain, and a higher probability of not exceeding C∗ .

  16. 40 CFR 147.3003 - Aquifer exemptions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Ute Mountain Ute, and All Other New Mexico Tribes § 147.3003 Aquifer exemptions. (a) Aquifer... cleanup plan shall include an analysis of pre-injection water quality for the constituents required by the...

  17. 40 CFR 147.3003 - Aquifer exemptions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., Ute Mountain Ute, and All Other New Mexico Tribes § 147.3003 Aquifer exemptions. (a) Aquifer... cleanup plan shall include an analysis of pre-injection water quality for the constituents required by the...

  18. Hydrogeology and water quality of the Floridan aquifer system and effects of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Fort Stewart, Georgia

    USGS Publications Warehouse

    Clarke, John S.; Cherry, Gregory C.; Gonthier, Gerard

    2011-01-01

    Test drilling, field investigations, and digital modeling were completed at Fort Stewart, GA, during 2009?2010, to assess the geologic, hydraulic, and water-quality characteristics of the Floridan aquifer system and evaluate the effect of Lower Floridan aquifer (LFA) pumping on the Upper Floridan aquifer (UFA). This work was performed pursuant to the Georgia Environmental Protection Division interim permitting strategy for new wells completed in the LFA that requires simulation to (1) quantify pumping-induced aquifer leakage from the UFA to LFA, and (2) identify the equivalent rate of UFA pumping that would produce the same maximum drawdown in the UFA that anticipated pumping from LFA well would induce. Field investigation activities included (1) constructing a 1,300-foot (ft) test boring and well completed in the LFA (well 33P028), (2) constructing an observation well in the UFA (well 33P029), (3) collecting drill cuttings and borehole geophysical logs, (4) collecting core samples for analysis of vertical hydraulic conductivity and porosity, (5) conducting flowmeter and packer tests in the open borehole within the UFA and LFA, (6) collecting depth-integrated water samples to assess basic ionic chemistry of various water-bearing zones, and (7) conducting aquifer tests in new LFA and UFA wells to determine hydraulic properties and assess interaquifer leakage. Using data collected at the site and in nearby areas, model simulation was used to assess the effects of LFA pumping on the UFA. Borehole-geophysical and flowmeter data indicate the LFA at Fort Stewart consists of limestone and dolomitic limestone between depths of 912 and 1,250 ft. Flowmeter data indicate the presence of three permeable zones at depth intervals of 912-947, 1,090-1,139, and 1,211?1,250 ft. LFA well 33P028 received 50 percent of the pumped volume from the uppermost permeable zone, and about 18 and 32 percent of the pumped volume from the middle and lowest permeable zones, respectively. Chemical constituent concentrations increased with depth, and water from all permeable zones contained sulfate at concentrations that exceeded the U.S. Environmental Protection Agency secondary maximum contaminant level of 250 milligrams per liter. A 72-hour aquifer test pumped LFA well 33P028 at 740 gallons per minute (gal/min), producing about 39 ft of drawdown in the pumped well and about 0.4 foot in nearby UFA well 33P029. Simulation using the U.S. Geological Survey finite-difference code MODFLOW was used to determine long-term, steady-state flow in the Floridan aquifer system, assuming the LFA well was pumped continuously at a rate of 740 gal/min. Simulated steady-state drawdown in the LFA was identical to that observed in pumped LFA well 33P028 at the end of the 72-hour test, with values larger than 1 ft extending 4.4 square miles symmetrically around the pumped well. Simulated steady-state drawdown in the UFA resulting from pumping in LFA well 33P028 exceeded 1 ft within a 1.4-square-mile circular area, and maximum drawdown in the UFA was 1.1 ft. Leakage from the UFA through the Lower Floridan confining unit contributed about 98 percent of the water to the well; lateral flow from specified-head model boundaries contributed about 2 percent. About 80 percent of the water supplied to LFA well 33P028 originated from within 1 mile of the well, and 49 percent was derived from within 0.5 mile of the well. Vertical hydraulic gradients and vertical leakage are progressively higher near the LFA pumped well which results in a correspondingly higher contribution of water from the UFA to the pumped well at distances closer to the pumped well. Simulated pumping-induced interaquifer leakage from the UFA to the LFA totaled 725 gal/min (1.04 million gallons per day), whereas simulated pumping at 205 gal/min (0.3 million gallons per day) from UFA well 33P029 produced the equivalent maximum drawdown as pumping LFA well 33P028 at 740 gal/min during the aquifer test. This equivalent pumpin

  19. Hydrogeology and Analysis of Aquifer Characteristics in West-Central Pinellas County, Florida

    DTIC Science & Technology

    1999-01-01

    Hydrogeology and Analysis of Aquifer Characteristics in West-Central Pinellas County, Florida By James C. Broska and Holly L. Barnette U.S...Geological Survey Open-File Report 99–185 Prepared in cooperation with PINELLAS COUNTY Tallahassee, Florida 1999 Report Documentation Page Form ApprovedOMB No...4. TITLE AND SUBTITLE Hydrogeology and Analysis of Aquifer Characteristics in West-Central Pinellas County, Florida 5a. CONTRACT NUMBER 5b

  20. Smart Aquifer Characterisation validated using Information Theory and Cost benefit analysis

    NASA Astrophysics Data System (ADS)

    Moore, Catherine

    2016-04-01

    The field data acquisition required to characterise aquifer systems are time consuming and expensive. Decisions regarding field testing, the type of field measurements to make and the spatial and temporal resolution of measurements have significant cost repercussions and impact the accuracy of various predictive simulations. The Smart Aquifer Characterisation (SAC) research programme (New Zealand (NZ)) addresses this issue by assembling and validating a suite of innovative methods for characterising groundwater systems at the large, regional and national scales. The primary outcome is a suite of cost effective tools and procedures provided to resource managers to advance the understanding and management of groundwater systems and thereby assist decision makers and communities in the management of their groundwater resources, including the setting of land use limits that protect fresh water flows and quality and the ecosystems dependent on that fresh water. The programme has focused novel investigation approaches including the use of geophysics, satellite remote sensing, temperature sensing and age dating. The SMART (Save Money And Reduce Time) aspect of the programme emphasises techniques that use these passive cost effective data sources to characterise groundwater systems at both the aquifer and the national scale by: • Determination of aquifer hydraulic properties • Determination of aquifer dimensions • Quantification of fluxes between ground waters and surface water • Groundwater age dating These methods allow either a lower cost method for estimating these properties and fluxes, or a greater spatial and temporal coverage for the same cost. To demonstrate the cost effectiveness of the methods a 'data worth' analysis is undertaken. The data worth method involves quantification of the utility of observation data in terms of how much it reduces the uncertainty of model parameters and decision focussed predictions which depend on these parameters. Such decision focussed predictions can include many aspects of system behaviour which underpin management decisions e.g., drawdown of groundwater levels, salt water intrusion, stream depletion, or wetland water level. The value of a data type or an observation location (e.g. remote sensing data (Westerhoff 2015) or a distributed temperature sensing measurement) is greater the more it enhances the certainty with which the model is able to predict such environmental behaviour. By comparing the difference in predictive uncertainty with or without such data, the value of potential observations is assessed. This can easily be achieved using rapid linear predictive uncertainty analysis methods (Moore 2005, Moore and Doherty 2006). By assessing the tension between the cost of data acquisition and the predictive accuracy achieved by gathering these observations in a pareto analysis, the relative cost effectiveness of these novel methods can be compared with more traditional measurements (e.g. bore logs, aquifer pumping tests, and simultaneous stream loss gaugings) for a suite of pertinent groundwater management decisions (Wallis et al 2014). This comparison illuminates those field data acquisition methods which offer the best value for the specific issues managers face in any region, and also indicates the diminishing returns of increasingly large and expensive data sets. References: Wallis I, Moore C, Post V, Wolf L, Martens E, Prommer. Using predictive uncertainty analysis to optimise tracer test design and data acquisition. Journal of Hydrology 515 (2014) 191-204. Moore, C. (2005). The use of regularized inversion in groundwater model calibration and prediction uncertainty analysis. Thesis submitted for the degree of Doctor of Philosophy at The University of Queensland, Australia. Moore, C., and Doherty, D. (2005). Role of the calibration process in reducing model predictive error. Water Resources Research 41, no.5 W05050. Westerhoff RS. Using uncertainty of Penman and Penman-Monteith methods in combined satellite and ground-based evapotranspiration estimates. Remote Sensing of Environment 169, 102-112

  1. Estimation of hydraulic parameters from an unconfined aquifer test conducted in a glacial outwash deposit, Cape Cod, Massachusetts

    USGS Publications Warehouse

    Moench, A.F.; Garabedian, Stephen P.; LeBlanc, Denis R.

    2000-01-01

    An aquifer test conducted in a sand and gravel, glacial outwash deposit on Cape Cod, Massachusetts was analyzed by means of a model for flow to a partially penetrating well in a homogeneous, anisotropic unconfined aquifer. The model is designed to account for all significant mechanisms expected to influence drawdown in observation piezometers and in the pumped well. In addition to the usual fluid-flow and storage processes, additional processes include effects of storage in the pumped well, storage in observation piezometers, effects of skin at the pumped-well screen, and effects of drainage from the zone above the water table. The aquifer was pumped at a rate of 320 gallons per minute for 72-hours and drawdown measurements were made in the pumped well and in 20 piezometers located at various distances from the pumped well and depths below the land surface. To facilitate the analysis, an automatic parameter estimation algorithm was used to obtain relevant unconfined aquifer parameters, including the saturated thickness and a set of empirical parameters that relate to gradual drainage from the unsaturated zone. Drainage from the unsaturated zone is treated in this paper as a finite series of exponential terms, each of which contains one empirical parameter that is to be determined. It was necessary to account for effects of gradual drainage from the unsaturated zone to obtain satisfactory agreement between measured and simulated drawdown, particularly in piezometers located near the water table. The commonly used assumption of instantaneous drainage from the unsaturated zone gives rise to large discrepancies between measured and predicted drawdown in the intermediate-time range and can result in inaccurate estimates of aquifer parameters when automatic parameter estimation procedures are used. The values of the estimated hydraulic parameters are consistent with estimates from prior studies and from what is known about the aquifer at the site. Effects of heterogeneity at the site were small as measured drawdowns in all piezometers and wells were very close to the simulated values for a homogeneous porous medium. The estimated values are: specific yield, 0.26; saturated thickness, 170 feet; horizontal hydraulic conductivity, 0.23 feet per minute; vertical hydraulic conductivity, 0.14 feet per minute; and specific storage, 1.3x10-5 per foot. It was found that drawdown in only a few piezometers strategically located at depth near the pumped well yielded parameter estimates close to the estimates obtained for the entire data set analyzed simultaneously. If the influence of gradual drainage from the unsaturated zone is not taken into account, specific yield is significantly underestimated even in these deep-seated piezometers. This helps to explain the low values of specific yield often reported for granular aquifers in the literature. If either the entire data set or only the drawdown in selected deep-seated piezometers was used, it was found unnecessary to conduct the test for the full 72-hours to obtain accurate estimates of the hydraulic parameters. For some piezometer groups, practically identical results would be obtained for an aquifer test conducted for only 8-hours. Drawdowns measured in the pumped well and piezometers at distant locations were diagnostic only of aquifer transmissivity.

  2. University of Minnesota Aquifer Thermal Energy Storage Field Test Facility

    NASA Astrophysics Data System (ADS)

    Walton, M.; Hoyer, M. C.

    1982-12-01

    The University of Minnesota Aquifer Thermal Energy Storage (ATES) Field Test Facility became operational. Experiments demonstrated that the Franconia-Ironton-Galesville aquifer will accept injection of 300 gpm (18.9 1 sec (-1)) at reasonable pressures with a heat buildup in the injection well of about 44 psi (31.6 m) over 8 days. Heating of the ground water caused precipitation of carbonate in the piping and injection well, but with proper water conditioning, the system will work satisfactorily at elevated temperatures.

  3. Remedial Investigation Report. Volume 11. North Central Study Area, Section 1.0 Text. Version 3.3

    DTIC Science & Technology

    1989-07-01

    Soils ... ........... NCSA 1.5-1 Summary of Alluvial Aquifer Pumping Tests ............ NCSA 1.5-2 Summary of Aquifer Parameters-Alluvial Aquifer...NCSA 1.5-3 Summary of Results for Pumping Tests in the Denver Formation ............ ...................... NCSA 1.5-4 Summary of Hydraulic...of fluid was pumped to Basin C and the liner was repaired. The remaining fluid in Basins A and C was transferred to Basin F, which by this time was

  4. Stochastic modeling of a lava-flow aquifer system

    USGS Publications Warehouse

    Cronkite-Ratcliff, Collin; Phelps, Geoffrey A.

    2014-01-01

    This report describes preliminary three-dimensional geostatistical modeling of a lava-flow aquifer system using a multiple-point geostatistical model. The purpose of this study is to provide a proof-of-concept for this modeling approach. An example of the method is demonstrated using a subset of borehole geologic data and aquifer test data from a portion of the Calico Hills Formation, a lava-flow aquifer system that partially underlies Pahute Mesa, Nevada. Groundwater movement in this aquifer system is assumed to be controlled by the spatial distribution of two geologic units—rhyolite lava flows and zeolitized tuffs. The configuration of subsurface lava flows and tuffs is largely unknown because of limited data. The spatial configuration of the lava flows and tuffs is modeled by using a multiple-point geostatistical simulation algorithm that generates a large number of alternative realizations, each honoring the available geologic data and drawn from a geologic conceptual model of the lava-flow aquifer system as represented by a training image. In order to demonstrate how results from the geostatistical model could be analyzed in terms of available hydrologic data, a numerical simulation of part of an aquifer test was applied to the realizations of the geostatistical model.

  5. Hydraulic and mechanical properties affecting ground-water flow and aquifer-system compaction, San Joaquin Valley, California

    USGS Publications Warehouse

    Sneed, Michelle

    2001-01-01

    This report summarizes hydraulic and mechanical properties affecting ground-water flow and aquifer-system compaction in the San Joaquin Valley, a broad alluviated intermontane structural trough that constitutes the southern two-thirds of the Central Valley of California. These values will be used to constrain a coupled ground-water flow and aquifer-system compaction model of the western San Joaquin Valley called WESTSIM. A main objective of the WESTSIM model is to evaluate potential future land subsidence that might occur under conditions in which deliveries of imported surface water for agricultural use are reduced and ground-water pumping is increased. Storage values generally are components of the total aquifer-system storage and include inelastic and elastic skeletal storage values of the aquifers and the aquitards that primarily govern the potential amount of land subsidence. Vertical hydraulic conductivity values generally are for discrete thicknesses of sediments, usually aquitards, that primarily govern the rate of land subsidence. The data were compiled from published sources and include results of aquifer tests, stress-strain analyses of borehole extensometer observations, laboratory consolidation tests, and calibrated models of aquifer-system compaction.

  6. Recovery of Ground-Water Levels From 1988 to 2003 and Analysis of Potential Water-Supply Management Options in Critical Area 1, East-Central New Jersey

    USGS Publications Warehouse

    Spitz, Frederick J.; Watt, Martha K.; dePaul, Vincent T.

    2008-01-01

    Water levels in four confined aquifers in the New Jersey Coastal Plain within Water Supply Critical Area 1 have recovered as a result of reductions in ground-water withdrawals initiated by the State in the late 1980s. The aquifers are the Wenonah-Mount Laurel, the Upper and Middle Potomac-Raritan-Magothy, and Englishtown aquifer system. Because of increased water demand due to increased development in Monmouth, Ocean, and Middlesex Counties, five base and nine alternate management models were designed for the four aquifers to evaluate the effects resulting from potential reallocation of part of the Critical Area 1 reductions in withdrawals. The change in withdrawals and associated water-level changes in the aquifers for 1988-2003 are discussed. Generally, withdrawals decreased 25 to 30 Mgal/d (million gallons per day), and water levels increased 0 to 80 ft (feet). The Regional Aquifer-System Analysis (RASA) ground-water-flow model of the New Jersey Coastal Plain developed by the U.S. Geological Survey was used to simulate ground-water flow and optimize withdrawals using the Ground-Water Management Process (GWM) for MODFLOW. Results of the model were used to evaluate the effects of several possible water-supply management options in order to provide the information to water managers. The optimization method, which provides a means to set constraints that support mandated hydrologic conditions, then determine the maximum withdrawals that meet the constraints, is a more cost-effective approach than simulating a range of withdrawals to determine the effects on the aquifer system. The optimization method is particularly beneficial for a regional-scale study of this kind because of the large number of wells to be evaluated. Before the model was run, a buffer analysis was done to define an area with no additional withdrawals that minimizes changes in simulated streamflow in aquifer outcrop areas and simulated movement of ground water toward the wells from areas of possible high chloride concentrations in the northern and southern parts of the Critical Area. Five base water-supply management models were developed. Each management model has an objective function, decision variables, and constraints. Two of the five management models were test cases: clean slate option and reallocation from the Wenonah-Mount Laurel aquifer and Englishtown aquifer system to small volume wells for potable water use. Nine other models also were developed as part of a trade-off analysis between withdrawal amounts and constraint values. The 14 management models included current (2003) or regularly spaced well locations with variations on the constraints of ground-water head, drawdown, velocity at the 250-mg/L (milligram per liter) isochlor, and withdrawal rate. Results of each management model were evaluated in terms of withdrawals, heads, saltwater intrusion, and source of water by aquifer. Each trade-off curve was defined by using six to nine separate management model runs. Results of the management models designed in this study indicate that a withdrawal reallocation of 5 to 20 Mgal/d within Critical Area 1 would increase the area of heads below -30 ft and the velocity at the 250-mg/L isochlor by up to 4 times that of the simulated 2003 results; the range of values are 0 to 521 square miles and 1 to 20 feet per year, respectively. The increase in area of heads below -30 ft was larger in the Middle Potomac-Raritan-Magothy aquifer than in other aquifers because that area was negligible in 2003. The range of modeled withdrawals is closely tied to management-model design. Interpretation of management model results is provided as well as a discussion of limitations.

  7. First status report on regional ground-water flow modeling for the Paradox Basin, Utah

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, R.W.

    1984-05-01

    Regional ground-water flow within the principal hydrogeologic units of the Paradox Basin is evaluated by developing a conceptual model of the flow regime in the shallow aquifers and the deep-basin brine aquifers and testing these models using a three-dimensional, finite-difference flow code. Semiquantitative sensitivity analysis (a limited parametric study) is conducted to define the system response to changes in hydrologic properties or boundary conditions. A direct method for sensitivity analysis using an adjoint form of the flow equation is applied to the conceptualized flow regime in the Leadville limestone aquifer. All steps leading to the final results and conclusions aremore » incorporated in this report. The available data utilized in this study is summarized. The specific conceptual models, defining the areal and vertical averaging of litho-logic units, aquifer properties, fluid properties, and hydrologic boundary conditions, are described in detail. Two models were evaluated in this study: a regional model encompassing the hydrogeologic units above and below the Paradox Formation/Hermosa Group and a refined scale model which incorporated only the post Paradox strata. The results are delineated by the simulated potentiometric surfaces and tables summarizing areal and vertical boundary fluxes, Darcy velocities at specific points, and ground-water travel paths. Results from the adjoint sensitivity analysis include importance functions and sensitivity coefficients, using heads or the average Darcy velocities to represent system response. The reported work is the first stage of an ongoing evaluation of the Gibson Dome area within the Paradox Basin as a potential repository for high-level radioactive wastes.« less

  8. Testing alternative conceptual models of seawater intrusion in a coastal aquifer using computer simulation, southern California, USA

    USGS Publications Warehouse

    Nishikawa, Tracy

    1997-01-01

    Two alternative conceptual models of the physical processes controlling seawater intrusion in a coastal basin in California, USA, were tested to identify a likely principal pathway for seawater intrusion. The conceptual models were tested by using a two-dimensional, finite-element groundwater flow and transport model. This pathway was identified by the conceptual model that best replicated the historical data. The numerical model was applied in cross section to a submarine canyon that is a main avenue for seawater to enter the aquifer system underlying the study area. Both models are characterized by a heterogeneous, layered, water-bearing aquifer. However, the first model is characterized by flat-lying aquifer layers and by a high value of hydraulic conductivity in the basal aquifer layer, which is thought to be a principal conduit for seawater intrusion. The second model is characterized by offshore folding, which was modeled as a very nearshore outcrop, thereby providing a shorter path for seawater to intrude. General conclusions are that: 1) the aquifer system is best modeled as a flat, heterogeneous, layered system; 2) relatively thin basal layers with relatively high values of hydraulic conductivity are the principal pathways for seawater intrusion; and 3) continuous clay layers of low hydraulic conductivity play an important role in controlling the movement of seawater.

  9. Data for four geologic test holes in the Sacramento Valley, California

    USGS Publications Warehouse

    Berkstresser, C.F.; French, J.J.; Schaal, M.E.

    1985-01-01

    The report provides geological and geophysical data for four of seven test holes drilled as a part of the Central Valley Aquifer Project, which is part of the Regional Aquifer Systems Analysis. The holes were drilled with a rotary well drilling machine to depths of 900 feet in the southwestern part of the Sacramento Valley in Solano and Yolo Counties. Geologic data for each well include lithology, texture, color, character of the contact, sorting, rounding, and cementation, determined from cuttings, cores, and sidewall covers. Fifty cores, 3 feet long, were obtained from each hole, and from eight to fourteen sidewall cores were collected. Geophysical data include a dual-induction log, spherically focused log (SFL), compensated neutron-formation density log, gamma-ray log, and a caliper log. These data are presented in four tables and on four plates. (USGS)

  10. Hydraulic characterization of aquifers by thermal response testing

    NASA Astrophysics Data System (ADS)

    Wagner, Valentin; Blum, Philipp; Bayer, Peter

    2014-05-01

    Temperature as a major physical quantity of the subsurface, and naturally occurring thermal anomalies are recognized as promising passive tracers to characterize the subsurface. Accelerated by the increasing popularity of geothermal energy, also active thermal field experiments have gained interest in hydrogeology. Such experiments involve artificial local ground heating or cooling. Among these, the thermal response test (TRT) is one of the most established field investigation techniques in shallow geothermal applications. It is a common method to investigate important subsurface heat transport parameters to design sustainable ground-source heat pump (GSHP) systems. During the test, the borehole heat exchanger (BHE) is heated up with a defined amount of energy by circulating a heat carrier fluid. By comparing temperature change between BHE inlet and outlet, the ability of the BHE to transfer heat or cold to the ambient ground is assessed. However, standard interpretation does not provide any insight into the governing processes of in-situ heat transfer. We utilize a groundwater advection sensitive TRT evaluation approach based on the analytical moving line source equation. It is shown that the TRT as a classical geothermal field test can also be used as a hydrogeological field test. Our approach benefits from the fact that thermal properties, such as thermal conductivity, of natural aquifers typically are much less variable than hydraulic properties, such as hydraulic conductivity. It is possible to determine a relatively small hydraulic conductivity range with our TRT evaluation approach, given realistic ranges for thermal conductivity, volumetric heat capacity, thermal dispersivity and thermal borehole resistance. The method is successfully tested on a large-scale geothermal laboratory experiment (9 m × 6 m × 4.5 m) and with a commercially performed TRT in the field scale. The laboratory experiment consists of a layered artificial aquifer, which is penetrated by a short BHE. This BHE is used to record a groundwater influenced TRT dataset. The performed field TRT is measured at a BHE located in the Upper Rhine Valley in South-West Germany, which penetrates a 68 m thick gravel aquifer with significant horizontal groundwater flow. At both sites, the derived hydraulic conductivity ranges obtained from TRT evaluation are shown to be within the ranges obtained from classical hydrogeological methods such as sieve analysis and pumping tests. This confirms that the temperature signal recorded during thermal response tests can be employed as a thermal tracer and that the evaluation of such a signal can be applied to estimate aquifer hydraulic conductivities.

  11. Simulation of a long-term aquifer test conducted near the Rio Grande, Albuquerque, New Mexico

    USGS Publications Warehouse

    McAda, Douglas P.

    2001-01-01

    A long-term aquifer test was conducted near the Rio Grande in Albuquerque during January and February 1995 using 22 wells and piezometers at nine sites, with the City of Albuquerque Griegos 1 production well as the pumped well. Griegos 1 discharge averaged about 2,330 gallons per minute for 54.4 days. A three-dimensional finite-difference ground-water-flow model was used to estimate aquifer properties in the vicinity of the Griegos well field and the amount of infiltration induced into the aquifer system from the Rio Grande and riverside drains as a result of pumping during the test. The model was initially calibrated by trial-and-error adjustments of the aquifer properties. The model was recalibrated using a nonlinear least-squares regression technique. The aquifer system in the area includes the middle Tertiary to Quaternary Santa Fe Group and post-Santa Fe Group valley- and basin-fill deposits of the Albuquerque Basin. The Rio Grande and adjacent riverside drains are in hydraulic connection with the aquifer system. The hydraulic-conductivity values of the upper part of the Santa Fe Group resulting from the model calibrated by trial and error varied by zone in the model and ranged from 12 to 33 feet per day. The hydraulic conductivity of the inner-valley alluvium was 45 feet per day. The vertical to horizontal anisotropy ratio was 1:140. Specific storage was 4 x 10-6 per foot of aquifer thickness, and specific yield was 0.15 (dimensionless). The sum of squared errors between the observed and simulated drawdowns was 130 feet squared. Not all aquifer properties could be estimated using nonlinear regression because of model insensitivity to some aquifer properties at observation locations. Hydraulic conductivity of the inner-valley alluvium, middle part of the Santa Fe Group, and riverbed and riverside-drain bed and specific yield had low sensitivity values and therefore could not be estimated. Of the properties estimated, hydraulic conductivity of the upper part of the Santa Fe Group was estimated to be 12 feet per day, the vertical to horizontal anisotropy ratio was estimated to be 1:82, and specific storage was estimated to be 1.2 x 10-6 per foot of aquifer thickness. The overall sum of squared errors between the observed and simulated drawdowns was 87 feet squared, a significant improvement over the model calibrated by trial and error. At the end of aquifer-test pumping, induced infiltration from the Rio Grande and riverside drains was simulated to be 13 percent of the total amount of water pumped. The remainder was water removed from aquifer storage. After pumping stopped, induced infiltration continued to replenish aquifer storage. Simulations estimated that 5 years after pumping began (about 4.85 years after pumping stopped), 58 to 72 percent of the total amount of water pumped was replenished by induced infiltration from the Rio Grande surface-water system.

  12. Characterization of a multilayer aquifer using open well dilution tests.

    PubMed

    West, L Jared; Odling, Noelle E

    2007-01-01

    An approach to characterization of multilayer aquifer systems using open well borehole dilution is described. The approach involves measuring observation well flow velocities while a nearby extraction well is pumped by introducing a saline tracer into observation wells and collecting dilution vs. depth profiles. Inspection of tracer profile evolution allows discrete permeable layers within the aquifer to be identified. Dilution profiles for well sections between permeable layers are then converted into vertical borehole flow velocities and their evolution, using an analytic solution to the advection-dispersion equation applied to borehole flow. The dilution approach is potentially able to measure much smaller flow velocities that would be detectable using flowmeters. Vertical flow velocity data from the observation wells are then matched to those generated using a hydraulic model of the aquifer system, "shorted" by the observation wells, to yield the hydraulic properties of the constituent layers. Observation well flow monitoring of pumping tests represents a cost-effective alternative or preliminary approach to pump testing each layer of a multilayer aquifer system separately using straddle packers or screened wells and requires no prior knowledge of permeable layer depths and thicknesses. The modification described here, of using tracer dilution rather than flowmeter logging to obtain well flow velocities, allows the approach to be extended to greater well separations, thus characterizing a larger volume of the aquifer. An example of the application of this approach to a multilayer Chalk Aquifer in Yorkshire, Northeast England, is presented.

  13. Shallow Carbon Sequestration Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pendergrass, Gary; Fraley, David; Alter, William

    The potential for carbon sequestration at relatively shallow depths was investigated at four power plant sites in Missouri. Exploratory boreholes were cored through the Davis Shale confining layer into the St. Francois aquifer (Lamotte Sandstone and Bonneterre Formation). Precambrian basement contact ranged from 654.4 meters at the John Twitty Energy Center in Southwest Missouri to over 1100 meters near the Sioux Power Plant in St. Charles County. Investigations at the John Twitty Energy Center included 3D seismic reflection surveys, downhole geophysical logging and pressure testing, and laboratory analysis of rock core and water samples. Plans to perform injectivity tests atmore » the John Twitty Energy Center, using food grade CO{sub 2}, had to be abandoned when the isolated aquifer was found to have very low dissolved solids content. Investigations at the Sioux Plant and Thomas Hill Energy Center in Randolph County found suitably saline conditions in the St. Francois. A fourth borehole in Platte County was discontinued before reaching the aquifer. Laboratory analyses of rock core and water samples indicate that the St. Charles and Randolph County sites could have storage potentials worthy of further study. The report suggests additional Missouri areas for further investigation as well.« less

  14. A semi-analytical solution for slug tests in an unconfined aquifer considering unsaturated flow

    NASA Astrophysics Data System (ADS)

    Sun, Hongbing

    2016-01-01

    A semi-analytical solution considering the vertical unsaturated flow is developed for groundwater flow in response to a slug test in an unconfined aquifer in Laplace space. The new solution incorporates the effects of partial penetrating, anisotropy, vertical unsaturated flow, and a moving water table boundary. Compared to the Kansas Geological Survey (KGS) model, the new solution can significantly improve the fittings of the modeled to the measured hydraulic heads at the late stage of slug tests in an unconfined aquifer, particularly when the slug well has a partially submerged screen and moisture drainage above the water table is significant. The radial hydraulic conductivities estimated with the new solution are comparable to those from the KGS, Bouwer and Rice, and Hvorslev methods. In addition, the new solution also can be used to examine the vertical conductivity, specific storage, specific yield, and the moisture retention parameters in an unconfined aquifer based on slug test data.

  15. Assessing groundwater availability and the response of the groundwater system to intensive exploitation in the North China Plain by analysis of long-term isotopic tracer data

    NASA Astrophysics Data System (ADS)

    Su, Chen; Cheng, Zhongshuang; Wei, Wen; Chen, Zongyu

    2018-03-01

    The use of isotope tracers as a tool for assessing aquifer responses to intensive exploitation is demonstrated and used to attain a better understanding of the sustainability of intensively exploited aquifers in the North China Plain. Eleven well sites were selected that have long-term (years 1985-2014) analysis data of isotopic tracers. The stable isotopes δ18O and δ2H and hydrochemistry were used to understand the hydrodynamic responses of the aquifer system, including unconfined and confined aquifers, to groundwater abstraction. The time series data of 14C activity were also used to assess groundwater age, thereby contributing to an understanding of groundwater sustainability and aquifer depletion. Enrichment of the heavy oxygen isotope (18O) and elevated concentrations of chloride, sulfate, and nitrate were found in groundwater abstracted from the unconfined aquifer, which suggests that intensive exploitation might induce the potential for aquifer contamination. The time series data of 14C activity showed an increase of groundwater age with exploitation of the confined parts of the aquifer system, which indicates that a larger fraction of old water has been exploited over time, and that the groundwater from the deep aquifer has been mined. The current water demand exceeds the sustainable production capabilities of the aquifer system in the North China Plain. Some measures must be taken to ensure major cuts in groundwater withdrawals from the aquifers after a long period of depletion.

  16. Cross-borehole flowmeter tests for transient heads in heterogeneous aquifers.

    PubMed

    Le Borgne, Tanguy; Paillet, Frederick; Bour, Olivier; Caudal, Jean-Pierre

    2006-01-01

    Cross-borehole flowmeter tests have been proposed as an efficient method to investigate preferential flowpaths in heterogeneous aquifers, which is a major task in the characterization of fractured aquifers. Cross-borehole flowmeter tests are based on the idea that changing the pumping conditions in a given aquifer will modify the hydraulic head distribution in large-scale flowpaths, producing measurable changes in the vertical flow profiles in observation boreholes. However, inversion of flow measurements to derive flowpath geometry and connectivity and to characterize their hydraulic properties is still a subject of research. In this study, we propose a framework for cross-borehole flowmeter test interpretation that is based on a two-scale conceptual model: discrete fractures at the borehole scale and zones of interconnected fractures at the aquifer scale. We propose that the two problems may be solved independently. The first inverse problem consists of estimating the hydraulic head variations that drive the transient borehole flow observed in the cross-borehole flowmeter experiments. The second inverse problem is related to estimating the geometry and hydraulic properties of large-scale flowpaths in the region between pumping and observation wells that are compatible with the head variations deduced from the first problem. To solve the borehole-scale problem, we treat the transient flow data as a series of quasi-steady flow conditions and solve for the hydraulic head changes in individual fractures required to produce these data. The consistency of the method is verified using field experiments performed in a fractured-rock aquifer.

  17. Evaluation of aquifer interconnection from aquifer characteristics computed by using specific capacity data within the vicinity of the Tremont Barrel Fill site, Clark County, Ohio

    USGS Publications Warehouse

    Gahala, Amy M.

    2015-01-01

    The results of the hydraulic analysis from 127 wells open to either the sand and gravel or the limestone aquifer indicate that the transmissivity of these aquifers is within one order of magnitude and horizontal hydraulic conductivity is within two orders of magnitude. As such, on the basis of the applied ranking system the two aquifers can be considered hydraulically interconnected.

  18. Geohydrology of the Flints Pond Aquifer, Hollis, New Hampshire

    USGS Publications Warehouse

    Ayotte, Joseph D.; Dorgan, Tracy H.

    1995-01-01

    Flints pond has been subjected to accelerated eutrophication as a result of watershed development (building of new homes and conversion of summer cottages into permanent homes) since the 1930's. Ground-water flow is the primary recharge and discharge mechanism for Flints Pond. The saturated thickness, transmissive properties, and altitude of the water table were determined by use of surface geophysics, test drilling, and aquifer-test data. Information on the geohydrology of the adjacent Flints Pond aquifer can be used in developing a water and nutrient budget for the pond-aquifer system. Ground-penetrating-radar surveys were done over more than 4 miles of the study area and on Flints Pond. Three distinct reflection signatures were commonly identifiable on the radar profiles: (1) thin, relatively flat-lying, continuous reflectors that represent fine-grained lacustrine sediment; (2) subparallel to hummocky and chaotic, coarse-grained reflectors that possibly represent coarse-grained ice-contact deposits or deltaic sediments in a lacustrine environment; and (3) sharply diffracted, fine-grained, chaotic reflectors that represent till and (or) till over bedrock. The saturated thickness of the aquifer exceeds 90 feet in the northern end of the study area and averages 30 to 50 feet in the southern and eastern parts. The saturated thickness of the western part is generally less than 10 feet. Test borings were completed at 19 sites and 13 wells (6 of which were nested pairs) were installed in various lithologic units. A water-table map, constructed from data collected in November 1994, represents average water-table conditions in the aquifer. Horizontal hydraulic conductivities calculated from single-well aquifer test data for stratified drift range from 2.8 to 226 feet per day. Hydraulic conductivities were quantitatively correlated with the reflector signatures produced with ground-penetrating radar so that transmissivities could be inferred for areas where well data were unavailable but where ground- penetrating-radar surveys were done. A saturated- thickness and transmissivity map for the aquifer shows that transmissivities exceeds 3,000 feet squared per day in the southern and east-central parts of the aquifer. Transmissivity ranges from 1,000 to 2,000 feet squared per day in the northern part of the aquifer and is generally less than 1,000 feet squared per day in the western part.

  19. The ground-water system and possible effects of underground coal mining in the Trail Mountain area, central Utah

    USGS Publications Warehouse

    Lines, Gregory C.

    1985-01-01

    The ground-water system was studied in the Trail Mountain area in order to provide hydrologic information needed to assess the hydrologic effects of underground coal mining. Well testing and spring data indicate that water occurs in several aquifers. The coal-bearing Blackhawk-Star Point aquifer is regional in nature and is the source of most water in underground mines in the region. One or more perched aquifers overlie the Blackhawk-Star Point aquifer in most areas of Trail Mountain.Aquifer tests indicate that the transmissivity of the Blackhawk-Star Point aquifer, which consists mainly of sandstone, siltstone, and shale, ranges from about 20 to 200 feet squared per day in most areas of Trail Mountain. The specific yield of the aquifer was estimated at 0.05, and the storage coefficient is about IxlO"6 per foot of aquifer where confined.The main sources of recharge to the multiaquifer system are snowmelt and rain, and water is discharged mainly by springs and by leakage along streams. Springs that issue from perched aquifers are sources of water for livestock and wildlife on Trail Mountain.Water in all aquifers is suitable for most uses. Dissolved solids concentrations range from about 250 to 700 milligrams per liter, and the predominant dissolved constituents generally are calcium, magnesium, and bicarbonate. Future underground coal mines will require dewatering when they penetrate the Blackhawk-Star Point aquifer. A finitedifference, three-dimensional computer model was used to estimate the inflow of water to various lengths and widths of a hypothetical dewatered mine and to estimate drawdowns of potentiometric surfaces in the partly dewatered aquifer. The estimates were made for a range of aquifer properties and premining hydraulic gradients that were similar to those on Trail Mountain. The computer simulations indicate that mine inflows could be several hundred gallons per minute and that potentiometric surfaces of the partly dewatered aquifer could be drawn down by several hundred feet during a reasonable life span of a mine. Because the Blackhawk-Star Point aquifer is separated from overlying perched aquifers by an unsaturated zone, mine dewatering alone would not affect perched aquifers. Mine dewatering would not significantly change water quality in the Blackhawk-Star Point aquifer. Subsidence will occur above future underground mines, but the effects on the ground-water system cannot be quantified. Subsidence fractures possibly could extend from the roof of a mine into a perched aquifer several hundred feet above. Such fractures would increase down ward percolation of water through the perching bed, and spring discharge from the perched aquifer could decrease. Flow through subsidence fractures also could increase recharge to the Blackhawk-Star Point aquifer and increase inflows to underground mines.

  20. Evaluation of unconfined-aquifer parameters from pumping test data by nonlinear least squares

    NASA Astrophysics Data System (ADS)

    Heidari, Manoutchehr; Wench, Allen

    1997-05-01

    Nonlinear least squares (NLS) with automatic differentiation was used to estimate aquifer parameters from drawdown data obtained from published pumping tests conducted in homogeneous, water-table aquifers. The method is based on a technique that seeks to minimize the squares of residuals between observed and calculated drawdown subject to bounds that are placed on the parameter of interest. The analytical model developed by Neuman for flow to a partially penetrating well of infinitesimal diameter situated in an infinite, homogeneous and anisotropic aquifer was used to obtain calculated drawdown. NLS was first applied to synthetic drawdown data from a hypothetical but realistic aquifer to demonstrate that the relevant hydraulic parameters (storativity, specific yield, and horizontal and vertical hydraulic conductivity) can be evaluated accurately. Next the method was used to estimate the parameters at three field sites with widely varying hydraulic properties. NLS produced unbiased estimates of the aquifer parameters that are close to the estimates obtained with the same data using a visual curve-matching approach. Small differences in the estimates are a consequence of subjective interpretation introduced in the visual approach.

  1. Evaluation of unconfined-aquifer parameters from pumping test data by nonlinear least squares

    USGS Publications Warehouse

    Heidari, M.; Moench, A.

    1997-01-01

    Nonlinear least squares (NLS) with automatic differentiation was used to estimate aquifer parameters from drawdown data obtained from published pumping tests conducted in homogeneous, water-table aquifers. The method is based on a technique that seeks to minimize the squares of residuals between observed and calculated drawdown subject to bounds that are placed on the parameter of interest. The analytical model developed by Neuman for flow to a partially penetrating well of infinitesimal diameter situated in an infinite, homogeneous and anisotropic aquifer was used to obtain calculated drawdown. NLS was first applied to synthetic drawdown data from a hypothetical but realistic aquifer to demonstrate that the relevant hydraulic parameters (storativity, specific yield, and horizontal and vertical hydraulic conductivity) can be evaluated accurately. Next the method was used to estimate the parameters at three field sites with widely varying hydraulic properties. NLS produced unbiased estimates of the aquifer parameters that are close to the estimates obtained with the same data using a visual curve-matching approach. Small differences in the estimates are a consequence of subjective interpretation introduced in the visual approach.

  2. U.S. Regional Aquifer Analysis Program

    NASA Astrophysics Data System (ADS)

    Johnson, Ivan

    As a result of the severe 1976-1978 drought, Congress in 1978 requested that the U.S. Geological Survey (USGS) initiate studies of the nation's aquifers on a regional scale. This continuing USGS project, the Regional Aquifer System Analysis (RASA) Program, consists of systematic studies of the quality and quantity of water in the regional groundwater systems that supply a large part of the nation's water.

  3. Trace organic chemical attenuation during managed aquifer recharge: Insights from a variably saturated 2D tank experiment

    NASA Astrophysics Data System (ADS)

    Regnery, Julia; Lee, Jonghyun; Drumheller, Zachary W.; Drewes, Jörg E.; Illangasekare, Tissa H.; Kitanidis, Peter K.; McCray, John E.; Smits, Kathleen M.

    2017-05-01

    Meaningful model-based predictions of water quality and quantity are imperative for the designed footprint of managed aquifer recharge installations. A two-dimensional (2D) synthetic MAR system equipped with automated sensors (temperature, water pressure, conductivity, soil moisture, oxidation-reduction potential) and embedded water sampling ports was used to test and model fundamental subsurface processes during surface spreading managed aquifer recharge operations under controlled flow and redox conditions at the meso-scale. The fate and transport of contaminants in the variably saturated synthetic aquifer were simulated using the finite element analysis model, FEFLOW. In general, the model concurred with travel times derived from contaminant breakthrough curves at individual sensor locations throughout the 2D tank. However, discrepancies between measured and simulated trace organic chemical concentrations (i.e., carbamazepine, sulfamethoxazole, tris (2-chloroethyl) phosphate, trimethoprim) were observed. While the FEFLOW simulation of breakthrough curves captured overall shapes of trace organic chemical concentrations well, the model struggled with matching individual data points, although compound-specific attenuation parameters were used. Interestingly, despite steady-state operation, oxidation-reduction potential measurements indicated temporal disturbances in hydraulic properties in the saturated zone of the 2D tank that affected water quality.

  4. Freshwater-saltwater transition zone movement during aquifer storage and recovery cycles in Brooklyn and Queens, New York City, USA

    USGS Publications Warehouse

    Misut, P.E.; Voss, C.I.

    2007-01-01

    Freshwater storage in deep aquifers of Brooklyn and Queens, New York, USA, is under consideration as an emergency water supply for New York City. The purpose of a New York City storage and recovery system is to provide an emergency water supply during times of drought or other contingencies and would entail longer-term storage phases than a typical annual cycle. There is concern amongst neighboring coastal communities that such a system would adversely impact their local water supplies via increased saltwater intrusion. This analysis uses three-dimensional modeling of variable-density ground-water flow and salt transport to study conditions under which hypothetical aquifer storage and recovery (ASR) may not adversely impact the coastal water supplies. A range of storage, pause, and recovery phase lengths and ASR cycle repetitions were used to test scenarios that emphasize control of potential saltwater intrusion. The USGS SUTRA code was used to simulate movement of the freshwater-saltwater transition zones in a detailed model of the upper glacial, Jameco, Magothy, and Lloyd aquifers of western Long Island, New York. Simulated transition zones in the upper glacial, Jameco, and Magothy aquifers reach a steady state for 1999 stress and recharge conditions within 1 ka; however, saltwater encroachment is ongoing in the Lloyd (deepest) aquifer, for which the effects of the rise in sea level since deglaciation on transition zone equilibration are retarded by many ka due to the thick, overlying Raritan confining unit. Pumping in the 20th century has also caused widening and landward movement of the Lloyd aquifer transition zone. Simulation of scenarios of freshwater storage by injection followed by phases of pause and recovery by extraction indicates that the effect of net storage when less water is recovered than injected is to set up a hydraulic saltwater intrusion barrier in the Lloyd aquifer which may have beneficial effects to coastal water users. ?? 2007 Elsevier B.V. All rights reserved.

  5. Freshwater saltwater transition zone movement during aquifer storage and recovery cycles in Brooklyn and Queens, New York City, USA

    NASA Astrophysics Data System (ADS)

    Misut, Paul E.; Voss, Clifford I.

    2007-04-01

    SummaryFreshwater storage in deep aquifers of Brooklyn and Queens, New York, USA, is under consideration as an emergency water supply for New York City. The purpose of a New York City storage and recovery system is to provide an emergency water supply during times of drought or other contingencies and would entail longer-term storage phases than a typical annual cycle. There is concern amongst neighboring coastal communities that such a system would adversely impact their local water supplies via increased saltwater intrusion. This analysis uses three-dimensional modeling of variable-density ground-water flow and salt transport to study conditions under which hypothetical aquifer storage and recovery (ASR) may not adversely impact the coastal water supplies. A range of storage, pause, and recovery phase lengths and ASR cycle repetitions were used to test scenarios that emphasize control of potential saltwater intrusion. The USGS SUTRA code was used to simulate movement of the freshwater-saltwater transition zones in a detailed model of the upper glacial, Jameco, Magothy, and Lloyd aquifers of western Long Island, New York. Simulated transition zones in the upper glacial, Jameco, and Magothy aquifers reach a steady state for 1999 stress and recharge conditions within 1 ka; however, saltwater encroachment is ongoing in the Lloyd (deepest) aquifer, for which the effects of the rise in sea level since deglaciation on transition zone equilibration are retarded by many ka due to the thick, overlying Raritan confining unit. Pumping in the 20th century has also caused widening and landward movement of the Lloyd aquifer transition zone. Simulation of scenarios of freshwater storage by injection followed by phases of pause and recovery by extraction indicates that the effect of net storage when less water is recovered than injected is to set up a hydraulic saltwater intrusion barrier in the Lloyd aquifer which may have beneficial effects to coastal water users.

  6. Transient well flow in vertically heterogeneous aquifers

    NASA Astrophysics Data System (ADS)

    Hemker, C. J.

    1999-11-01

    A solution for the general problem of computing well flow in vertically heterogeneous aquifers is found by an integration of both analytical and numerical techniques. The radial component of flow is treated analytically; the drawdown is a continuous function of the distance to the well. The finite-difference technique is used for the vertical flow component only. The aquifer is discretized in the vertical dimension and the heterogeneous aquifer is considered to be a layered (stratified) formation with a finite number of homogeneous sublayers, where each sublayer may have different properties. The transient part of the differential equation is solved with Stehfest's algorithm, a numerical inversion technique of the Laplace transform. The well is of constant discharge and penetrates one or more of the sublayers. The effect of wellbore storage on early drawdown data is taken into account. In this way drawdowns are found for a finite number of sublayers as a continuous function of radial distance to the well and of time since the pumping started. The model is verified by comparing results with published analytical and numerical solutions for well flow in homogeneous and heterogeneous, confined and unconfined aquifers. Instantaneous and delayed drainage of water from above the water table are considered, combined with the effects of partially penetrating and finite-diameter wells. The model is applied to demonstrate that the transient effects of wellbore storage in unconfined aquifers are less pronounced than previous numerical experiments suggest. Other applications of the presented solution technique are given for partially penetrating wells in heterogeneous formations, including a demonstration of the effect of decreasing specific storage values with depth in an otherwise homogeneous aquifer. The presented solution can be a powerful tool for the analysis of drawdown from pumping tests, because hydraulic properties of layered heterogeneous aquifer systems with partially penetrating wells may be estimated without the need to construct transient numerical models. A computer program based on the hybrid analytical-numerical technique is available from the author.

  7. GIS-based model of groundwater occurrence using geological and hydrogeological data in Precambrian Oban Massif southeastern Nigeria

    NASA Astrophysics Data System (ADS)

    Sikakwe, Gregory Udie

    2018-06-01

    This research modeled geological and hydrogeological controls on groundwater occurrence in Oban Massif and environs southeastern Nigeria. Topographical, hydrogeological, and structural maps, including lithology samples from drilled bores, well completion, and pumping test data in the study area were procured. Collection of coordinates of rock sample locations and structural data on strike and dip of rock exposures was collected. Geological and structural information collected was overlaid on the topographical, hydrogeological and structural map and digitized to produce the geological map of the study area. Thematic map on geological groundwater prospect map of the study was prepared using multicriteria evaluation. Relative weights were assigned to various rock types based on their relative contribution to groundwater occurrence and the map was reclassified using geographic information system (ArcGIS10.1) analysis. Depth ranges of the various lithologic units from drilled boreholes were used to construct lithologic correlation section of the boreholes across the study area using RockWorks16 Program software. Hydrogeological parameters such as storativity, specific capacity, transmissivity, drawdown, pumping rate, static water level, total depth, and well yield were computed from well completion reports and aquifer test. Results shows that the geologic groundwater prospect map was categorized into very good (28.73 m2), good (9.66 m2), moderate (35.08 m2), fair (49.38 m2), and poor (77.63 m2) zones. Aquifer parameters showed ranges such as (specific capacity (1.81-31.16 m2/day/m), transmissivity (0.0033-12 m2/day), storativity (9.4 × 10-3-2.3), drawdown (2.2-17.65 m), pumping rate (0.75-3.57 l/s), static water level (0-20.5 m), and total depth (3.3-61 m). Borehole depths obtained in the basement are shallower than those in the sedimentary area. Aquifer test parameters obtained from boreholes across the study indicate better correspondence with zones identified as good water prospect in the study. It was evident that well yield is not a very reliable aquifer performance indicator, because it depends largely on the efficiency of the pump installed. Therefore, other aquifer parameters must be employed in aquifer performance assessment. The geologic formation is paramount in determining aquifer performance. The result of this groundwater occurrence is useful as a guide for groundwater developers, which engineers in water resource management and land-use planners to select suitable areas to implement development schemes and also government agencies.

  8. Interlaboratory study of a method for determining nonvolatile organic carbon in aquifer materials

    USGS Publications Warehouse

    Caughey, M.E.; Barcelona, M.J.; Powell, R.M.; Cahill, R.A.; Gron, C.; Lawrenz, D.; Meschi, P.L.

    1995-01-01

    The organic carbon fraction in aquifer materials exerts a major influence on the subsurface mobilities of organic and organic-associated contaminants. The spatial distribution of total organic carbon (TOC) in aquifer materials must be determined before the transport of hydrophobic organic pollutants in aquifers can be modeled accurately. Previous interlaboratory studies showed that it is difficult to measure TOC concentrations 1%. We have tested a new analytical method designed to improve the accuracy and precision of nonvolatile TOC quantitation in geologic materials that also contain carbonate minerals. Four authentic aquifer materials and one NIST standard reference material were selected as test materials for a blind collaborative study. Nonvolatile TOC in these materials ranged from 0.05 to 1.4%, while TIC ranged from 0.46 to 12.6%. Sample replicates were digested with sulfurous acid, dried at 40??C, and then combusted at 950??C using LECO or UIC instruments. For the three test materials that contained >2% TIC, incomplete acidification resulted in a systematic positive bias of TOC values reported by five of the six laboratories that used the test method. Participants did not have enough time to become proficient with the new method before they analyzed the test materials. A seventh laboratory successfully used an alternative method that analyzed separate liquid and solid fractions of the acidified sample residues. ?? 1995 Springer-Verlag.

  9. Hydrogeologic and hydrochemical framework, south-central Great Basin, Nevada-California, with special reference to the Nevada Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winograd, I.J.; Thordarson, W.

    Intensely fractured Precambrian and Paleozoic carbonate and clastic rocks and block-faulted Cenozoic volcanic and sedimentary strata in the Nevada Test Site are divided into 10 hydrogeologic units. Three of these--the lower clastic aquitard, the lower carbonate aquifer, and the tuff aquitard--control the regional movement of ground water. The coefficients of fracture transmissiblity of these rocks are, respectively, less than 1,000, 1,000 to 900,000, and less than 200 gallons per day per foot; interstitial permeability is negligible. Solution caverns are locally present in the carbonate aquifer, but regional movement of water is controlled by variations in fracture transmissibility and by structuralmore » juxtaposition of the aquifer and the lower clastic aquitard. Water circulates freely to depths of at least 1,500 feet beneath the top of the aquifer and up to 4,200 feet below land surface. Synthesis of hydrogeologic, hydrochemical, and isotopic data suggests that an area of at least 4,500 square miles (including 10 intermontane valleys) is hydraulically integrated into one ground-water basin, the Ash Meadows basin, by interbasin movement of ground water through the widespread carbonate aquifer. Discharge from this basin--a minimum of about 17,000 acre-feet annually--occurs along a fault-controlled spring line at Ash Meadows in east-central Amargosa Desert. Intrabasin movement of water between Cenozoic aquifers and the lower carbonate aquifer is controlled by the tuff aquitard, the basal Cenozoic hydrogeologic unit. Such movement significantly influences the chemistry of water in the carbonate aquifer. Ground-water velocity through the tuff aquitard in Yucca Flat is less than 1 foot per year. Velocity through the lower carbonate aquifer ranges from an estimated 0.02 to 200 feet per day, depending upon geographic position within the flow system.Within the Nevada Test Site, ground water moves southward and southwestward toward Ash Meadows.« less

  10. Analysis of an anisotropic coastal aquifer system using variable-density flow and solute transport simulation

    USGS Publications Warehouse

    Souza, W.R.; Voss, C.I.

    1987-01-01

    The groundwater system in southern Oahu, Hawaii consists of a thick, areally extensive freshwater lens overlying a zone of transition to a thick saltwater body. This system is analyzed in cross section with a variable-density groundwater flow and solute transport model on a regional scale. The simulation is difficult, because the coastal aquifer system has a saltwater transition zone that is broadly dispersed near the discharge area, but is very sharply defined inland. Steady-state simulation analysis of the transition zone in the layered basalt aquifer of southern Oahu indicates that a small transverse dispersivity is characteristic of horizontal regional flow. Further, in this system flow is generally parallel to isochlors and steady-state behavior is insensitive to the longitudinal dispersivity. Parameter analysis identifies that only six parameters control the complex hydraulics of the system: horizontal and vertical hydraulic conductivity of the basalt aquifer; hydraulic conductivity of the confining "caprock" layer; leakance below the caprock; specific yield; and aquifer matrix compressibility. The best-fitting models indicate the horizontal hydraulic conductivity is significantly greater than the vertical hydraulic conductivity. These models give values for specific yield and aquifer compressibility which imply a considerable degree of compressive storage in the water table aquifer. ?? 1987.

  11. Uncertainty Quantification and Assessment of CO2 Leakage in Groundwater Aquifers

    NASA Astrophysics Data System (ADS)

    Carroll, S.; Mansoor, K.; Sun, Y.; Jones, E.

    2011-12-01

    Complexity of subsurface aquifers and the geochemical reactions that control drinking water compositions complicate our ability to estimate the impact of leaking CO2 on groundwater quality. We combined lithologic field data from the High Plains Aquifer, numerical simulations, and uncertainty quantification analysis to assess the role of aquifer heterogeneity and physical transport on the extent of CO2 impacted plume over a 100-year period. The High Plains aquifer is a major aquifer over much of the central United States where CO2 may be sequestered in depleted oil and gas reservoirs or deep saline formations. Input parameters considered included, aquifer heterogeneity, permeability, porosity, regional groundwater flow, CO2 and TDS leakage rates over time, and the number of leakage source points. Sensitivity analysis suggest that variations in sand and clay permeability, correlation lengths, van Genuchten parameters, and CO2 leakage rate have the greatest impact on impacted volume or maximum distance from the leak source. A key finding is that relative sensitivity of the parameters changes over the 100-year period. Reduced order models developed from regression of the numerical simulations show that volume of the CO2-impacted aquifer increases over time with 2 order of magnitude variance.

  12. Hydrogeology of the surficial and intermediate aquifer systems in Sarasota and adjacent counties, Florida

    USGS Publications Warehouse

    Barr, G.L.

    1996-01-01

    From 1991 to 1995, the hydrogeology of the surficial aquifer system and the major permeable zones and confining units of the intermediate aquifer system in southwest Florida was studied. The study area is a 1,400-square-mile area that includes Sarasota County and parts of Manatee, De Soto, Charlotte, and Lee Counties. Lithologic, geophysical, hydraulic property, and water-level data were used to correlate the hydrogeology and map the extent of the aquifer systems. Water chemistry was evaluated in southwest Sarasota County to determine salinity of the surficial and intermediate aquifer systems. The surficial aquifer is an unconfined aquifer system that overlies the intermediate aquifer system and ranges from a few feet to over 60 feet in thickness in the study area. Hydraulic properties of the surficial aquifer system determined from aquifer and laboratory tests, and model simulations vary considerably across the study area. The intermediate aquifer system, a confined aquifer system that lies between the surficial and the Upper Floridan aquifers, is composed of alternating confining units and permeable zones. The intermediate aquifer system has three major permeable zones that exhibit a wide range of hydraulic properties. Horizontal flow in the intermediate aquifer system is northeast to southwest. Most of the study area is in a discharge area of the intermediate aquifer system. Water ranges naturally from fresh in the surficial aquifer system and upper permeable zones of the intermediate aquifer system to moderately saline in the lower permeable zone. Water-quality data collected in coastal southwest Sarasota County indicate that ground-water withdrawals from major pumping centers have resulted in lateral seawater intrusion and upconing into the surficial and intermediate aquifer systems.

  13. The use of salinity contrast for density difference compensation to improve the thermal recovery efficiency in high-temperature aquifer thermal energy storage systems

    NASA Astrophysics Data System (ADS)

    van Lopik, Jan H.; Hartog, Niels; Zaadnoordijk, Willem Jan

    2016-08-01

    The efficiency of heat recovery in high-temperature (>60 °C) aquifer thermal energy storage (HT-ATES) systems is limited due to the buoyancy of the injected hot water. This study investigates the potential to improve the efficiency through compensation of the density difference by increased salinity of the injected hot water for a single injection-recovery well scheme. The proposed method was tested through numerical modeling with SEAWATv4, considering seasonal HT-ATES with four consecutive injection-storage-recovery cycles. Recovery efficiencies for the consecutive cycles were investigated for six cases with three simulated scenarios: (a) regular HT-ATES, (b) HT-ATES with density difference compensation using saline water, and (c) theoretical regular HT-ATES without free thermal convection. For the reference case, in which 80 °C water was injected into a high-permeability aquifer, regular HT-ATES had an efficiency of 0.40 after four consecutive recovery cycles. The density difference compensation method resulted in an efficiency of 0.69, approximating the theoretical case (0.76). Sensitivity analysis showed that the net efficiency increase by using the density difference compensation method instead of regular HT-ATES is greater for higher aquifer hydraulic conductivity, larger temperature difference between injection water and ambient groundwater, smaller injection volume, and larger aquifer thickness. This means that density difference compensation allows the application of HT-ATES in thicker, more permeable aquifers and with larger temperatures than would be considered for regular HT-ATES systems.

  14. Hydrostratigraphic interpretation of test-hole and surface geophysical data, Elkhorn and Loup River Basins, Nebraska, 2008 to 2011

    USGS Publications Warehouse

    Hobza, Christopher M.; Bedrosian, Paul A.; Bloss, Benjamin R.

    2012-01-01

    The Elkhorn-Loup Model (ELM) was begun in 2006 to understand the effect of various groundwater-management scenarios on surface-water resources. During phase one of the ELM study, a lack of subsurface geological information was identified as a data gap. Test holes drilled to the base of the aquifer in the ELM study area are spaced as much as 25 miles apart, especially in areas of the western Sand Hills. Given the variable character of the hydrostratigraphic units that compose the High Plains aquifer system, substantial variation in aquifer thickness and characteristics can exist between test holes. To improve the hydrogeologic understanding of the ELM study area, the U.S. Geological Survey, in cooperation with the Nebraska Department of Natural Resources, multiple Natural Resources Districts participating in the ELM study, and the University of Nebraska-Lincoln Conservation and Survey Division, described the subsurface lithology at six test holes drilled in 2010 and concurrently collected borehole geophysical data to identify the base of the High Plains aquifer system. A total of 124 time-domain electromagnetic (TDEM) soundings of resistivity were collected at and between selected test-hole locations during 2008-11 as a quick, non-invasive means of identifying the base of the High Plains aquifer system. Test-hole drilling and geophysical logging indicated the base-of-aquifer elevation was less variable in the central ELM area than in previously reported results from the western part of the ELM study area, where deeper paleochannels were eroded into the Brule Formation. In total, more than 435 test holes were examined and compared with the modeled-TDEM soundings. Even where present, individual stratigraphic units could not always be identified in modeled-TDEM sounding results if sufficient resistivity contrast was not evident; however, in general, the base of aquifer [top of the aquifer confining unit (ACU)] is one of the best-resolved results from the TDEM-based models, and estimates of the base-of-aquifer elevation are in good accordance with those from existing test-hole data. Differences between ACU elevations based on modeled-TDEM and test-hole data ranged from 2 to 113 feet (0.6 to 34 meters). The modeled resistivity results reflect the eastward thinning of Miocene-age and older stratigraphic units, and generally allowed confident identification of the accompanying change in the stratigraphic unit forming the ACU. The differences in elevation of the top of the Ogallala, estimated on the basis of the modeled-TDEM resistivity, and the test-hole data ranged from 11 to 251 feet (3.4 to 77 meters), with two-thirds of model results being within 60 feet of the test-hole contact elevation. The modeled-TDEM soundings also provided information regarding the distribution of Plio-Pleistocene gravel deposits, which had an average thickness of 100 feet (30 meters) in the study area; however, in many cases the contact between the Plio-Pleistocene deposits and the overlying Quaternary deposits cannot be reliably distinguished using TDEM soundings alone because of insufficient thickness or resistivity contrast.

  15. Hydrodispersive characterization of a sandy porous medium by tracer tests carried out in laboratory on undisturbed soil samples

    NASA Astrophysics Data System (ADS)

    Ferrante, Aldo Pedro; Fallico, Carmine; Rios, Ana C.; Fernanda Rivera, Maria; Santillan, Patricio; Salazar, Mario

    2013-04-01

    The contamination of large areas and correspondent aquifers often imposes to implement some recovery operations which are generally complex and very expensive. Anyway, these interventions necessarily require the preventive characterization of the aquifers to be reclaimed and in particular the knowledge of the relevant hydrodispersive parameters. The determination of these parameters requires the implementation tracer tests for the specific site (Sauty JP, 1978). To reduce cost and time that such test requires tracer tests on undisturbed soil samples, representative of the whole aquifer, can be performed. These laboratory tests are much less expensive and require less time, but the results are certainly less reliable than those obtained by field tests for several reasons, including the particular scale of investigation. In any case the hydrodispersive parameters values, obtained by tests carried out in laboratory, can provide useful information on the considered aquifer, allowing to carry out initial verifications on the transmission and propagation of the pollutants in the aquifer considered. For this purpose, tracer tests with inlet of short time were carried out in the Soil Physics Laboratory of the Department of Soil Protection (University of Calabria), on a series of sandy soil samples with six different lengths, repeating each test with three different water flow velocities (5 m/d; 10 m/s and 15 m/d) (J. Feyen et al., 1998). The lengths of the samples taken into account are respectively 15 cm, 24 cm, 30 cm, 45 cm, 60 cm and 75 cm, while the solution used for each test was made of 100 ml of water and NaCl with a concentration of this substance corresponding to 10 g/L. For the porous medium taken into consideration a particle size analysis was carried out, resulting primarily made of sand, with total porosity equal to 0.33. Each soil sample was placed in a flow cell in which was inlet the tracer from the bottom upwards, measuring by a conductivimeter the variation of the outgoing concentration over time and obtaining the respective breakthrough curve. The flow was induced and regulated by a peristaltic pump. The results obtained are consistent together with those obtained by other researchers for analogues soil types; moreover the existence of a scaling law for the hydrodispersive parameters considered, ie the longitudinal dispersivity (?L) and the longitudinal dispersion coefficient (DL), was also verified (Neuman S.P., 1990), (Schulze-Makuch D., 2005). References Feyen J. et al., 1998. "Modelling Water Flow and Solute Transport in Heterogeneous Soils: A Review of Recent Approaches", Silsoe Research Institute. Neuman S.P., 1990. "Universal Scaling of Hydraulic Conductivities and Dispersivities in Geologic Media", Water Resources Research, vol. 26. Schulze-Makuch D., 2005. "Longitudinal Dispersivity Data and Implications for Scaling Behavior", Ground Water, vol.43. Sauty J.P., 1978. "Identification des paramètres du transport hydrodispersif dans les aquifères par interprétation de traçages en ecoulement cylindrique convergent ou divergent", Journal of hydrology n. 39.

  16. Relation of bedrock aquifer property and geological structure in Mockcheon area, Korea

    NASA Astrophysics Data System (ADS)

    Hamm, S.-Y.; Kang, L. S.; Choi, S. J.; Lee, B. D.

    2003-04-01

    In Korea, 72 companies are producing natural mineral water mostly from bedrock aquifer of different depths (Sung et al., 2002). It is important to insure quantity of natural mineral water. However, when several natural mineral-water companies are gathered in small area, the amount of producing water can be often limited by pumping rate of the companies in the area. In the study area, five natural mineral water producing companies (Siwon Semmul, Daejeong Eumryo, Jain Guanguang, Cheongsu Eumryo and Hanju Sikpum) are located in range of 2 km radius. Consequently, wells for natural mineral water of five companies and other private wells are drilled in Mockchun area. These wells produce groundwater from bedrock with total discharge rate 1,991m3/day. Thus, it is necessary to understand the hydrogeological characteristics of bedrock groundwater to preserve groundwater quantity in the study area. Geology was investigated to understand geological structure controlling aquifer characteristics in the study area. Precambrian metamorphic rocks (metamorphosed limestone, biotite schist, augen gneiss and porphyroblastic gneiss) are intruded by Jurassic porphyritic granite and two-mica granite and by numerous acidic and intermediate dykes. Alluvium overlies older rocks by unconformity (Kang and Lim, 1974; Shin et al., 1975). Two NS-direction thrusts are developed in the study area. Main aquifer is formed between the lower thrust and the upper thrust, and the lower thrust plays role as impermeable layer. It is considered that the main aquifer was developed by brecciation during the thrust faulting. Thus, pumping wells of mineral water are also located along the thrusts. Wells of Siwon Semmul, Daejeong Eumryo and Jain Guanguang mineral water producing companies are drilled in different aquifers. However, the wells of Chungsoo Eumryo and Hanjoo Sikpoom are drilled in the same aquifer, and are influenced each other during pumping. To understand hydrogeological characteristics, field hydraulic tests (slug and pumping tests) were conducted in wells of the five companies. Pumping and slug test data were interpreted using several models to get best solution. For slug test, Cooper-Bredehoeft-Papadopulos, Bouwer &Rice, Hvorslev methods were used. In slug test, the calculated values of transmissivity and storativity by C-B-P method's range from 6.60E-3 to 3.23E-8 m2/sec, from 0.1 to 1E-10, respectively. Hydraulic conductivities by Bouwer &Rice and Hvorslev method range from 1.03E-4 to 7.47E-8 m/sec and from 1.15E-4 to 9.45 E-8 m/sec, respectively. As the models of pumping test, Hantush's "Wedge-shape confined aquifer model" (1962) and Moench-case 1 leaky-aquifer model" (1985) were adequate for the most cases. The pumping test models match well with geological information that indicates wedge-shaped aquifer. From the pumping test, the estimates of transmissivity and storativity by Hantush's and Moench-case 1's methods range from 1.23E-1 to 2.87E-6 m2/sec, from 1.34 E-1 to 2.27E-8 m2/sec, respectively.

  17. Transient bacterial contamination of the dual-porosity aquifer at Walkerton, Ontario, Canada

    NASA Astrophysics Data System (ADS)

    Worthington, Stephen R. H.; Smart, C. Christopher

    2017-06-01

    Contamination of the Paleozoic carbonate aquifer at Walkerton (Ontario, Canada) by pathogenic bacteria following heavy rain in May 2000 resulted in 2,300 illnesses and seven deaths. Subsequent tracer testing showed that there was rapid groundwater flow in the aquifer, and also rapid exchange between the aquifer and the ground surface. Electrical conductivity (EC) profiling during a 3-day pumping test showed that most flow was through bedding-plane fractures spaced about 10 m apart, that there were substantial contrasts in EC in the major fracture flows, and that there were rapid changes over time. Total coliform sampling revealed transient groundwater contamination, particularly after heavy rain and lasting up to a few days. These characteristics can be understood in terms of the dual-porosity nature of the aquifer. Most of the storage is in the matrix, but this can be considered to be static in the short term. Almost all transport is through the fracture network, which has rapid groundwater flow (˜100 m/day) and rapid transmission of pressure pulses due to the high hydraulic diffusivity. Rapid recharge can occur through thin and/or fractured overburden and at spring sites where flow is reversed by pumping during episodes of surface flooding. These characteristics facilitated the ingress of surface-derived bacteria into the aquifer, and their rapid transport within the aquifer to pumping wells. Bacterial presence is common in carbonate aquifers, and this can be explained by the well-connected, large-aperture fracture networks in these dual-porosity aquifers, even though many, such as at Walkerton, lack karst landforms.

  18. Hydrogeology and analysis of ground-water-flow system, Sagamore Marsh area, southeastern Massachusetts

    USGS Publications Warehouse

    Walter, Donald A.; Masterson, John P.; Barlow, Paul M.

    1996-01-01

    A study of the hydrogeology and an analysis of the ground-water-flow system near Sagamore Marsh, southeastern Massachusetts, was undertaken to improve the understanding of the current (1994­ 95) hydrogeologic conditions near the marsh and how the ground-water system might respond to proposed changes in the tidal-stage regime of streams that flood and drain the marsh. Sagamore Marsh is in a coastal area that is bounded to the east by Cape Cod Bay and to the south by the Cape Cod Canal. The regional geology is characterized by deltaic and glaciolacustrine sediments. The sediments consist of gravel, sand, silt, and clay and are part of the Plymouth-Carver regional aquifer system. The glacial sediments are hounded laterally by marine sand, silt, and clay along the coast. The principal aquifer in the area consists of fine to coarse glacial sand and is locally confined by fine-grained glaciolacustrine deposits consisting of silt and sandy clay and fine-grained salt-marsh sediments consisting of peat and clay. The aquifer is underlain by finer grained glaciolacustrine sediments in upland areas and by marine clay along the coast.Shallow ground water discharges primarily along the edge of the marsh, whereas deeper ground water flows beneath the marsh and discharges to Cape Cod Bay. Tidal pulses originating from Cape Cod Bay and from tidal channels in the marsh are rapidly attenuated in the subsurface. Tidal ranges in Cape Cod Bay and in the tidal channels were on the order of 9 and 1.5 feet, respectively, whereas tidal ranges in the ground-water levels were less than 0.2 foot. Tidal pulses measured in the water table beneath a barrier beach between the marsh and Cape Cod Bay were more in phase with tidal pulses from Cape Cod Bay than with tidal pulses from the tidal channels in Sagamore Marsh, whereas tidal pulses in the regional aquifer were more in phase with tidal pulses from the tidal channels. A 5-day aquifer test at a public-supply well adjacent to the marsh gave a transmissivity of the regional aquifer of 9,300 to 10,900 feet squared per day and a hydraulic conductivity of 181 to 213 feet per day, assuming a saturated thickness of the aquifer of 51.3 feet. The regional aquifer became unconfined near the pumped well during the test. The ratio of tidal ranges in the tidal channel to the ranges in the underlying aquifer at two sites (the lower and upper marsh) indicated aquifer diffusivities for the marsh sediments of 380 and 170 feet squared per day; these values correspond to hydraulic conductivities of 2.5 x 10-3 and 1.7 x 10-3 feet per day, respectively. The maximum distances from the tidal channel at the lower and upper marsh sites where tidal ranges would exceed 0.01 foot, as calculated from aquifer diffusivities and current (1995) tidal ranges in the tidal channels, were 24.4 and 26.7 feet, respectively. The maximum distances from the tidal channel where tidal pulses in the ground water would exceed 0.01 foot, using potential increased tidal stages resulting from proposed tidal-stage modifications and predicted by the U.S. Army Corps of Engineers, were 37.1 and 42.0 feet, respectively. A numerical model of the marsh and surrounding aquifer system indicated that the contributing area for the supply well adjacent to the marsh, for current (1994) pumping conditions, extends toward Great Herring Pond, about 2 miles northwest (upgradient) of the well, and does not extend beneath the marsh. The model also indicates that the predicted increases in tidal stages in the marsh will have a negligible effect on local ground-water levels.

  19. Hydrogeology of a drift-filled bedrock valley near Lino Lakes, Anoka County, Minnesota

    USGS Publications Warehouse

    Winter, T.C.; Pfannkuch, H.O.

    1976-01-01

    The bedrock surface of east-central Minnesota is dissected by an intricate network of valleys. Outside the bedrock valley at site B, 3 mi (4. 8 km) from site A, 100 ft (30 m) of drift overlies the bedrock surface. Observation wells were installed at the two sites to determine the vertical ground-water movement between the various aquifer units and the lateral movement between the two sites. An aquifer test of the lowest valley-fill aquifer at site A showed that the observation well completed in the same aquifer as the pumping well responded immediately; whereas a lag of about 100 min occurred between the lower valley fill and uppermost body of sand and gravel. This indicates that the hydraulic connection between these two layers is poor at the immediate site. Test results show that the lower sand-and-gravel aquifer has a transmissivity between 14,000 and 27,000 ft2/d (1,300 and 2,500 m2/d). Although the hydraulic gradient is vertically downward in the valley, much of the drift fill is poorly permeable. This suggests that the quantity of downward-percolating water reaching the lowest valley-fill aquifer is relatively small at the test site. Because valley cut through a number of bedrock aquifers in the region, they could potentially be an important avenue of contamination from land-surface waste. In addition, the vast network of bedrock valleys in the Twin Cities area might cause contaminants to disseminate rather rapidly throughout a large area.

  20. A multi-directional tracer test in the fractured Chalk aquifer of E. Yorkshire, UK.

    PubMed

    Hartmann, S; Odling, N E; West, L J

    2007-12-07

    A multi-borehole radial tracer test has been conducted in the confined Chalk aquifer of E. Yorkshire, UK. Three different tracer dyes were injected into three injection boreholes and a central borehole, 25 m from the injection boreholes, was pumped at 330 m(3)/d for 8 days. The breakthrough curves show that initial breakthrough and peak times were fairly similar for all dyes but that recoveries varied markedly from 9 to 57%. The breakthrough curves show a steep rise to a peak and long tail, typical of dual porosity aquifers. The breakthrough curves were simulated using a 1D dual porosity model. Model input parameters were constrained to acceptable ranges determined from estimations of matrix porosity and diffusion coefficient, fracture spacing, initial breakthrough times and bulk transmissivity of the aquifer. The model gave equivalent hydraulic apertures for fractures in the range 363-384 microm, dispersivities of 1 to 5 m and matrix block sizes of 6 to 9 cm. Modelling suggests that matrix block size is the primary controlling parameter for solute transport in the aquifer, particularly for recovery. The observed breakthrough curves suggest results from single injection-borehole tracer tests in the Chalk may give initial breakthrough and peak times reasonably representative of the aquifer but that recovery is highly variable and sensitive to injection and abstraction borehole location. Consideration of aquifer heterogeneity suggests that high recoveries may be indicative of a high flow pathway adjacent, but not necessarily connected, to the injection and abstraction boreholes whereas low recoveries may indicate more distributed flow through many fractures of similar aperture.

  1. A multiphased approach to groundwater investigations for the Edwards-Trinity and related aquifers in the Pecos County region, Texas

    USGS Publications Warehouse

    Thomas, Jonathan V.

    2014-01-01

    The Edwards-Trinity aquifer is a vital groundwater resource for agricultural, industrial, and public supply uses in the Pecos County region of western Texas. Resource managers would like to understand the future availability of water in the Edwards-Trinity aquifer in the Pecos County region and the effects of the possible increase or temporal redistribution of groundwater withdrawals. To provide resource managers with that information, the U.S. Geological Survey (USGS), in cooperation with the Middle Pecos Groundwater Conservation District, Pecos County, City of Fort Stockton, Brewster County, and Pecos County Water Control and Improvement District No. 1, completed a three-phase study of the Edwards-Trinity and related aquifers in parts of Brewster, Jeff Davis, Pecos, and Reeves Counties. The first phase was to collect groundwater, surface-water, geochemical, geophysical, and geologic data in the study area and develop a geodatabase of historical and collected data. Data compiled in the first phase of the study were used to develop the conceptual model in the second phase of the study. The third phase of the study involved the development and calibration of a numerical groundwater-flow model of the Edwards-Trinity aquifer to simulate groundwater conditions based on various groundwater-withdrawal scenarios. Analysis of well, geophysical, geochemical, and hydrologic data contributed to the development of the conceptual model in phase 1. Lithologic information obtained from well reports and geophysical data was used to describe the hydrostratigraphy and structural features of the groundwater-flow system, and aquifer-test data were used to estimate aquifer hydraulic properties. Geochemical data were used to evaluate groundwater-flow paths, water-rock interaction, aquifer interaction, and the mixing of water from different sources in phase 2. Groundwater-level data also were used to evaluate aquifer interaction, as well as to develop a potentiometric-surface map, delineate regional groundwater divides, and describe regional groundwater-flow paths. During phase 3, the data collected and compiled along with the conceptual information in the study area were incorporated into a numerical groundwater-flow model to evaluate the sustainability of recent (2008) and projected water-use demands on groundwater resources in the study area.

  2. Aquifer response to stream-stage and recharge variations. II. Convolution method and applications

    USGS Publications Warehouse

    Barlow, P.M.; DeSimone, L.A.; Moench, A.F.

    2000-01-01

    In this second of two papers, analytical step-response functions, developed in the companion paper for several cases of transient hydraulic interaction between a fully penetrating stream and a confined, leaky, or water-table aquifer, are used in the convolution integral to calculate aquifer heads, streambank seepage rates, and bank storage that occur in response to streamstage fluctuations and basinwide recharge or evapotranspiration. Two computer programs developed on the basis of these step-response functions and the convolution integral are applied to the analysis of hydraulic interaction of two alluvial stream-aquifer systems in the northeastern and central United States. These applications demonstrate the utility of the analytical functions and computer programs for estimating aquifer and streambank hydraulic properties, recharge rates, streambank seepage rates, and bank storage. Analysis of the water-table aquifer adjacent to the Blackstone River in Massachusetts suggests that the very shallow depth of water table and associated thin unsaturated zone at the site cause the aquifer to behave like a confined aquifer (negligible specific yield). This finding is consistent with previous studies that have shown that the effective specific yield of an unconfined aquifer approaches zero when the capillary fringe, where sediment pores are saturated by tension, extends to land surface. Under this condition, the aquifer's response is determined by elastic storage only. Estimates of horizontal and vertical hydraulic conductivity, specific yield, specific storage, and recharge for a water-table aquifer adjacent to the Cedar River in eastern Iowa, determined by the use of analytical methods, are in close agreement with those estimated by use of a more complex, multilayer numerical model of the aquifer. Streambank leakance of the semipervious streambank materials also was estimated for the site. The streambank-leakance parameter may be considered to be a general (or lumped) parameter that accounts not only for the resistance of flow at the river-aquifer boundary, but also for the effects of partial penetration of the river and other near-stream flow phenomena not included in the theoretical development of the step-response functions.Analytical step-response functions, developed for several cases of transient hydraulic interaction between a fully penetrating stream and a confined, leaky, or water-table aquifer, are used in the convolution integral to calculate aquifer heads, streambank seepage rates, and bank storage that occur in response to stream-stage fluctuations and basinwide recharge or evapotranspiration. Two computer programs developed on the basis of these step-response functions and the convolution integral are applied to the analysis of hydraulic interaction of two alluvial stream-aquifer systems. These applications demonstrate the utility of the analytical functions and computer programs for estimating aquifer and streambank seepage rates and bank storage.

  3. 36C1 measurements and the hydrology of an acid injection site

    USGS Publications Warehouse

    Vourvopoulos, G.; Brahana, J.V.; Nolte, E.; Korschinek, G.; Priller, A.; Dockhorn, B.

    1990-01-01

    In an area in western Tennessee (United States), an industrial firm is injecting acidic (pH = 0.1) iron chloride into permeable zones of carbonate rocks at depths ranging from 1000 to 2200 m below land surface. Overlying the injection zone at a depth of approximately 500 m below land surface is a regional fresh-water aquifer, the Knox aquifer. A study is currently underway to investigate whether the injection wells are hydraulically isolated from the fresh-water aquifer. Drilling of a test well that will reach a total depth of 2700 m has been initiated. The 36Cl content of 15 samples from the Knox aquifer, from monitor wells in the vicinity of the injection site, and from the test well have been analyzed. ?? 1990.

  4. Groundwater flow and water budget in the surficial and Floridan aquifer systems in east-central Florida

    USGS Publications Warehouse

    Sepúlveda, Nicasio; Tiedeman, Claire; O'Reilly, Andrew M.; Davis, Jeffrey B.; Burger, Patrick

    2012-01-01

    A numerical transient model of the surficial and Floridan aquifer systems in east-central Florida was developed to (1) increase the understanding of water exchanges between the surficial and the Floridan aquifer systems, (2) assess the recharge rates to the surficial aquifer system from infiltration through the unsaturated zone and (3) obtain a simulation tool that could be used by water-resource managers to assess the impact of changes in groundwater withdrawals on spring flows and on the potentiometric surfaces of the hydrogeologic units composing the Floridan aquifer system. The hydrogeology of east-central Florida was evaluated and used to develop and calibrate the groundwater flow model, which simulates the regional fresh groundwater flow system. The U.S. Geological Survey three-dimensional groundwater flow model, MODFLOW-2005, was used to simulate transient groundwater flow in the surficial, intermediate, and Floridan aquifer systems from 1995 to 2006. The East-Central Florida Transient model encompasses an actively simulated area of about 9,000 square miles. Although the model includes surficial processes-rainfall, irrigation, evapotranspiration (ET), runoff, infiltration, lake water levels, and stream water levels and flows-its primary purpose is to characterize and refine the understanding of groundwater flow in the Floridan aquifer system. Model-independent estimates of the partitioning of rainfall into ET, streamflow, and aquifer recharge are provided from a water-budget analysis of the surficial aquifer system. The interaction of the groundwater flow system with the surface environment was simulated using the Green-Ampt infiltration method and the MODFLOW-2005 Unsaturated-Zone Flow, Lake, and Streamflow-Routing Packages. The model is intended to simulate the part of the groundwater system that contains freshwater. The bottom and lateral boundaries of the model were established at the estimated depths where the chloride concentration is 5,000 milligrams per liter in the Floridan aquifer system. Potential flow across the interface represented by this chloride concentration is simulated by the General Head Boundary Package. During 1995 through 2006, there were no major groundwater withdrawals near the freshwater and saline-water interface, making the general head boundary a suitable feature to estimate flow through the interface. The east-central Florida transient model was calibrated using the inverse parameter estimation code, PEST. Steady-state models for 1999 and 2003 were developed to estimate hydraulic conductivity (K) using average annual heads and spring flows as observations. The spatial variation of K was represented using zones of constant values in some layers, and pilot points in other layers. Estimated K values were within one order of magnitude of aquifer performance test data. A simulation of the final two years (2005-2006) of the 12-year model, with the K estimates from the steady-state calibration, was used to guide the estimation of specific yield and specific storage values. The final model yielded head and spring-flow residuals that met the calibration criteria for the 12-year transient simulation. The overall mean residual for heads, defining residual as simulated minus measured value, was -0.04 foot. The overall root-mean square residual for heads was less than 3.6 feet for each year in the 1995 to 2006 simulation period. The overall mean residual for spring flows was -0.3 cubic foot per second. The spatial distribution of head residuals was generally random, with some minor indications of bias. Simulated average ET over the 1995 to 2006 period was 34.47 inches per year, compared to the calculated average ET rate of 36.39 inches per year from the model-independent water-budget analysis. Simulated average net recharge to the surficial aquifer system was 3.58 inches per year, compared with the calculated average of 3.39 inches per year from the model-independent water-budget analysis. Groundwater withdrawals from the Floridan aquifer system averaged about 920 million gallons per day, which is equivalent to about 2 inches per year over the model area and slightly more than half of the simulated average net recharge to the surficial aquifer system over the same period. Annual net simulated recharge rates to the surficial aquifer system were less than the total groundwater withdrawals from the Floridan aquifer system only during the below-average rainfall years of 2000 and 2006.

  5. Groundwater flow and water budget in the surficial and Floridan aquifer systems in east-central Florida

    USGS Publications Warehouse

    Sepúlveda, Nicasio; Tiedeman, Claire; O'Reilly, Andrew M.; Davis, Jeffery B.; Burger, Patrick

    2012-01-01

    A numerical transient model of the surficial and Floridan aquifer systems in east-central Florida was developed to (1) increase the understanding of water exchanges between the surficial and the Floridan aquifer systems, (2) assess the recharge rates to the surficial aquifer system from infiltration through the unsaturated zone and (3) obtain a simulation tool that could be used by water-resource managers to assess the impact of changes in groundwater withdrawals on spring flows and on the potentiometric surfaces of the hydrogeologic units composing the Floridan aquifer system. The hydrogeology of east-central Florida was evaluated and used to develop and calibrate the groundwater flow model, which simulates the regional fresh groundwater flow system. The U.S. Geological Survey three-dimensional groundwater flow model, MODFLOW-2005, was used to simulate transient groundwater flow in the surficial, intermediate, and Floridan aquifer systems from 1995 to 2006. The east-central Florida transient model encompasses an actively simulated area of about 9,000 square miles. Although the model includes surficial processes-rainfall, irrigation, evapotranspiration, runoff, infiltration, lake water levels, and stream water levels and flows-its primary purpose is to characterize and refine the understanding of groundwater flow in the Floridan aquifer system. Model-independent estimates of the partitioning of rainfall into evapotranspiration, streamflow, and aquifer recharge are provided from a water-budget analysis of the surficial aquifer system. The interaction of the groundwater flow system with the surface environment was simulated using the Green-Ampt infiltration method and the MODFLOW-2005 Unsaturated-Zone Flow, Lake, and Streamflow-Routing Packages. The model is intended to simulate the part of the groundwater system that contains freshwater. The bottom and lateral boundaries of the model were established at the estimated depths where the chloride concentration is 5,000 milligrams per liter in the Floridan aquifer system. Potential flow across the interface represented by this chloride concentration is simulated by the General Head Boundary Package. During 1995 through 2006, there were no major groundwater withdrawals near the freshwater and saline-water interface, making the general head boundary a suitable feature to estimate flow through the interface. The east-central Florida transient model was calibrated using the inverse parameter estimation code, PEST. Steady-state models for 1999 and 2003 were developed to estimate hydraulic conductivity (K) using average annual heads and spring flows as observations. The spatial variation of K was represented using zones of constant values in some layers, and pilot points in other layers. Estimated K values were within one order of magnitude of aquifer performance test data. A simulation of the final two years (2005-2006) of the 12-year model, with the K estimates from the steady-state calibration, was used to guide the estimation of specific yield and specific storage values. The final model yielded head and spring-flow residuals that met the calibration criteria for the 12-year transient simulation. The overall mean residual for heads, defining residual as simulated minus measured value, was -0.04 foot. The overall root-mean square residual for heads was less than 3.6 feet for each year in the 1995 to 2006 simulation period. The overall mean residual for spring flows was -0.3 cubic foot per second. The spatial distribution of head residuals was generally random, with some minor indications of bias. Simulated average evapotranspiration (ET) over the 1995 to 2006 period was 34.5 inches per year, compared to the calculated average ET rate of 36.6 inches per year from the model-independent water-budget analysis. Simulated average net recharge to the surficial aquifer system was 3.6 inches per year, compared with the calculated average of 3.2 inches per year from the model-independent waterbudget analysis. Groundwater withdrawals from the Floridan aquifer system averaged about 800 million gallons per day, which is equivalent to about 2 inches per year over the model area and slightly more than half of the simulated average net recharge to the surficial aquifer system over the same period. Annual net simulated recharge rates to the surficial aquifer system were less than the total groundwater withdrawals from the Floridan aquifer system only during the below-average rainfall years of 2000 and 2006.

  6. Test drilling and aquifer test in the Marburg schist near Mount Airy, Frederick County, Maryland

    USGS Publications Warehouse

    Meyer, Gerald

    1955-01-01

    This memorandum summarizes briefly the data obtained by test drilling and in an aquifer test at Mount Airy, Md. The tests were a part of the State - Federal cooperative study of the ground-water resources of Frederick County, and it is intended that a more complete analysis of the test data will be included in a future report describing the ground-water resource of Frederick County. The purpose of this memorandum is to make the test data immediately available to the general public. Mount Airy is located along the Carroll-Frederick County boundary bout 2 miles north of the intersection of U.S. Highway 40 with the county boundary. Its population is approximately 1,000. The municipal well field, consisting of two drilled wells (fig. 1) is in a valley about one-half mile west of the center of Mount Airy, within about 400 feet of a small stream, and north of Prospect Road. Well 1, about 40 feet north of Prospect Road, is 125 feet deep, 8 inches in diameter, and reportedly yielded 265 gallons per minute (gpm) in 1947 and 201 gpm in a half hour test in March 1955. The writer determined during the tests described in this memorandum that the well has about 34 feet of casing. Well 2, 85 feet north of well 1, is 96 feet deep, 8 inches in diameter, and reportedly yielded 120 gpm in 1947 and 127 gpm in a half hour test in March 1955. The wells are equipped with deep-well turbine pumps powered by electric motors. Cenorally only well 1 is used, and it is pumped for only a few short intervals each day to meet the water requirements of the town (about 75,000 - 80,000 gallons daily). The reported yields of these wells are considerably higher than the average for crystalline-rock wells in the Piedmont of Maryland. The test drilling was done under contract with Edward I. Brown, well driller, between May 3 and May 12, 1955. Water-supply facilities of the town of Mount Airy were kindly made available for the aquifer tests from May 22 to May 30, 1955. The pumping tests consisted of a step-drawdown and interference test on the public-supply wells on May 30, 1955, and aquifer test in which public-supply well 1 was pumped constantly for 48 hours and the effect of this pumpage was measured in all the wells and test holes on May 23-25.

  7. Semi-analytical solution of flow to a well in an unconfined-fractured aquifer system separated by an aquitard

    NASA Astrophysics Data System (ADS)

    Sedghi, Mohammad M.; Samani, Nozar; Barry, D. A.

    2018-04-01

    Semi-analytical solutions are presented for flow to a well in an extensive homogeneous and anisotropic unconfined-fractured aquifer system separated by an aquitard. The pumping well is of infinitesimal radius and screened in either the overlying unconfined aquifer or the underlying fractured aquifer. An existing linearization method was used to determine the watertable drainage. The solution was obtained via Laplace and Hankel transforms, with results calculated by numerical inversion. The main findings are presented in the form of non-dimensional drawdown-time curves, as well as scaled sensitivity-dimensionless time curves. The new solution permits determination of the influence of fractures, matrix blocks and watertable drainage parameters on the aquifer drawdown. The effect of the aquitard on the drawdown response of the overlying unconfined aquifer and the underlying fractured aquifer was also explored. The results permit estimation of the unconfined and fractured aquifer hydraulic parameters via type-curve matching or coupling of the solution with a parameter estimation code. The solution can also be used to determine aquifer hydraulic properties from an optimal pumping test set up and duration.

  8. Machine-readable files developed for the High Plains Regional Aquifer-System analysis in parts of Colorado, Kansas, Nebraska, New Mexico, Oklahoma, South Dakota, Texas, and Wyoming

    USGS Publications Warehouse

    Ferrigno, C.F.

    1986-01-01

    Machine-readable files were developed for the High Plains Regional Aquifer-System Analysis project are stored on two magnetic tapes available from the U.S. Geological Survey. The first tape contains computer programs that were used to prepare, store, retrieve, organize, and preserve the areal interpretive data collected by the project staff. The second tape contains 134 data files that can be divided into five general classes: (1) Aquifer geometry data, (2) aquifer and water characteristics , (3) water levels, (4) climatological data, and (5) land use and water use data. (Author 's abstract)

  9. Evaluation of recharge to the Skunk Creek Aquifer from a constructed wetland near Lyons, South Dakota

    USGS Publications Warehouse

    Thompson, Ryan F.

    2002-01-01

    A wetland was constructed in the Skunk Creek flood plain near Lyons in southeast South Dakota to mitigate for wetland areas that were filled during construction of a municipal golf course for the city of Sioux Falls. A water-rights permit was obtained to allow the city to pump water from Skunk Creek into the wetland during times when the wetland would be dry. The amount of water seeping through the wetland and recharging the underlying Skunk Creek aquifer was not known. The U.S. Geological Survey, in cooperation with the city of Sioux Falls, conducted a study during 1997-2000 to evaluate recharge to the Skunk Creek aquifer from the constructed wetland. Three methods were used to estimate recharge from the wetland to the aquifer: (1) analysis of the rate of water-level decline during periods of no inflow; (2) flow-net analysis; and (3) analysis of the hydrologic budget. The hydrologic budget also was used to evaluate the efficiency of recharge from the wetland to the aquifer. Recharge rates estimated by analysis of shut-off events ranged from 0.21 to 0.82 foot per day, but these estimates may be influenced by possible errors in volume calculations. Recharge rates determined by flow-net analysis were calculated using selected values of hydraulic conductivity and ranged from 566,000 gallons per day using a hydraulic conductivity of 0.5 foot per day to 1,684,000 gallons per day using a hydraulic conductivity of 1.0 foot per day. Recharge rates from the hydrologic budget varied from 0.74 to 0.85 foot per day, and averaged 0.79 foot per day. The amount of water lost to evapotranspiration at the study wetland is very small compared to the amount of water seeping from the wetland into the aquifer. Based on the hydrologic budget, the average recharge efficiency was estimated as 97.9 percent, which indicates that recharging the Skunk Creek aquifer by pumping water into the study wetland is highly efficient. Because the Skunk Creek aquifer is composed of sand and gravel, the 'recharge mound' is less distinct than might be found in an aquifer composed of finer materials. However, water levels recorded from piezometers in and around the wetland do show a higher water table than periods when the wetland was dry. The largest increases in water level occur between the wetland channel and Skunk Creek. The results of this study demonstrate that artificially recharged wetlands can be useful in recharging underlying aquifers and increasing water levels in these aquifers.

  10. A Microcomputer Program for Evaluating Pumping Test Results for Confined Aquifers.

    ERIC Educational Resources Information Center

    Smith, Stephen M.

    1986-01-01

    Describes an interactive, self-prompting BASIC program that can be incorporated in introductory and intermediate hydrology courses. Exlains how the program can be used to evaluate pumping test data and also to calculate transmissivity and storativity values of confined aquifers. The program is written for the IBM PC. (ML)

  11. Inventory and review of aquifer storage and recovery in southern Florida

    USGS Publications Warehouse

    Reese, Ronald S.

    2002-01-01

    publications > water resources investigations > report 02-4036 US Department of the Interior US Geological Survey WRI 02-4036Inventory and Review of Aquifer Storage and Recovery in Southern Florida By Ronald S. ReeseTallahassee, Florida 2002 prepared as part of the U.S. Geological Survey Place-Based Studies Program ABSTRACT Abstract Introduction Inventory of Data Case Studies Summary References Tables Aquifer storage and recovery in southern Florida has been proposed on an unprecedented scale as part of the Comprehensive Everglades Restoration Plan. Aquifer storage and recovery wells were constructed or are under construction at 27 sites in southern Florida, mostly by local municipalities or counties located in coastal areas. The Upper Floridan aquifer, the principal storage zone of interest to the restoration plan, is the aquifer being used at 22 of the sites. The aquifer is brackish to saline in southern Florida, which can greatly affect the recovery of the freshwater recharged and stored.Well data were inventoried and compiled for all wells at most of the 27 sites. Construction and testing data were compiled into four main categories: (1) well identification, location, and construction data; (2) hydraulic test data; (3) ambient formation water-quality data; and (4) cycle testing data. Each cycle during testing or operation includes periods of recharge of freshwater, storage, and recovery that each last days or months. Cycle testing data include calculations of recovery efficiency, which is the percentage of the total amount of potable water recharged for each cycle that is recovered.Calculated cycle test data include potable water recovery efficiencies for 16 of the 27 sites. However, the number of cycles at most sites was limited; except for two sites, the highest number of cycles was five. Only nine sites had a recovery efficiency above 10 percent for the first cycle, and 10 sites achieved a recovery efficiency above 30 percent during at least one cycle. The highest recovery efficiency achieved per cycle was 84 percent for cycle 16 at the Boynton Beach site.Factors that could affect recovery of freshwater varied widely between sites. The thickness of the open storage zone at all sites ranged from 45 to 452 feet. For sites with the storage zone in the Upper Floridan aquifer, transmissivity based on tests of the storage zones ranged from 800 to 108,000 feet squared per day, leakance values indicated that confinement is not good in some areas, and the chloride concentration of ambient water ranged from 500 to 11,000 milligrams per liter.Based on review of four case studies and data from other sites, several hydrogeologic and design factors appear to be important to the performance of aquifer storage and recovery in the Floridan aquifer system. Performance is maximized when the storage zone is thin and located at the top of the Upper Floridan aquifer, and transmissivity and salinity of the storage zone are moderate (less than 30,000 feet squared per day and 3,000 milligrams per liter of chloride concentration, respectively). The structural setting at a site could also be important because of the potential for updip migration of a recharged freshwater bubble due to density contrast or loss of overlying confinement due to deformation.

  12. Pumping tests in nonuniform aquifers - The radially symmetric case

    USGS Publications Warehouse

    Butler, J.J.

    1988-01-01

    Traditionally, pumping-test-analysis methodology has been limited to applications involving aquifers whose properties are assumed uniform in space. This work attempts to assess the applicability of analytical methodology to a broader class of units with spatially varying properties. An examination of flow behavior in a simple configuration consisting of pumping from the center of a circular disk embedded in a matrix of differing properties is the basis for this investigation. A solution describing flow in this configuration is obtained through Laplace-transform techniques using analytical and numerical inversion schemes. Approaches for the calculation of flow properties in conditions that can be roughly represented by this simple configuration are proposed. Possible applications include a wide variety of geologic structures, as well as the case of a well skin resulting from drilling or development. Of more importance than the specifics of these techniques for analysis of water-level responses is the insight into flow behavior during a pumping test that is provided by the large-time form of the derived solution. The solution reveals that drawdown during a pumping test can be considered to consist of two components that are dependent and independent of near-well properties, respectively. Such an interpretation of pumping-test drawdown allows some general conclusions to be drawn concerning the relationship between parameters calculated using analytical approaches based on curve-matching and those calculated using approaches based on the slope of a semilog straight line plot. The infinite-series truncation that underlies the semilog analytical approaches is shown to remove further contributions of near-well material to total drawdown. In addition, the semilog distance-drawdown approach is shown to yield an expression that is equivalent to the Thiem equation. These results allow some general recommendations to be made concerning observation-well placement for pumping tests in nonuniform aquifers. The relative diffusivity of material on either side of a discontinuity is shown to be the major factor in controlling flow behavior during the period in which the front of the cone of depression is moving across the discontinuity. Though resulting from an analysis of flow in an idealized configuration, the insights of this work into flow behavior during a pumping test are applicable to a wide class of nonuniform units. ?? 1988.

  13. Hydrology of the Coastal Lowlands aquifer system in parts of Alabama, Florida, Louisiana, and Mississippi

    USGS Publications Warehouse

    Martin, Angel; Whiteman, C.D.

    1999-01-01

    Existing data on water levels, water use, water quality, and aquifer properties were used to construct a multilayer digital model to simulate flow in the aquifer system. The report describes the geohydrologic framework of the aquifer system, and the development, calibration, and sensitivity analysis of the ground-water-flow model, but it is primarily focused on the results of the simulations that show the natural flow of ground water throughout the regional aquifer system and the changes from the natural flow caused by development of ground-water supplies.

  14. Ground-water appraisal in northwestern Big Stone County, west-central Minnesota

    USGS Publications Warehouse

    Soukup, W.G.

    1980-01-01

    Samples of water were collected for chemical analysis from wells in the surficial outwash, buried outwash, and Cretaceous aquifers. With the exception of nitrate, the greatest difference in chemical quality was between samples from the buried outwash and Cretaceous aquifers. Water from Cretaceous aquifers is softer than water from the outwash aquifers, but contains concentrations of sodium and boron that are high enough to damage soils and crops if used for irrigation. Nitrate concentrations exceeded the Minnesota Pollution Control Agency's recommended limits for drinking water in one sample from the surficial aquifer.

  15. THERMAL-ENERGY STORAGE IN A DEEP SANDSTONE AQUIFER IN MINNESOTA: FIELD OBSERVATIONS AND THERMAL ENERGY-TRANSPORT MODELING.

    USGS Publications Warehouse

    Miller, R.T.

    1986-01-01

    A study of the feasibility of storing heated water in a deep sandstone aquifer in Minnesota is described. The aquifer consists of four hydraulic zones that are areally anisotropic and have average hydraulic conductivities that range from 0. 03 to 1. 2 meters per day. A preliminary axially symmetric, nonisothermal, isotropic, single-phase, radial-flow, thermal-energy-transport model was constructed to investigate the sensitivity of model simulation to various hydraulic and thermal properties of the aquifer. A three-dimensional flow and thermal-energy transport model was constructed to incorporate the areal anisotropy of the aquifer. Analytical solutions of equations describing areally anisotropic groundwater flow around a doublet-well system were used to specify model boundary conditions for simulation of heat injection. The entire heat-injection-testing period of approximately 400 days was simulated. Model-computed temperatures compared favorably with field-recorded temperatures, with differences of no more than plus or minus 8 degree C. For each test cycle, model-computed aquifer thermal efficiency, defined as total heat withdrawn divided by total heat injected, was within plus or minus 2% of the field-calculated values.

  16. Effects of model layer simplification using composite hydraulic properties

    USGS Publications Warehouse

    Sepúlveda, Nicasio; Kuniansky, Eve L.

    2010-01-01

    The effects of simplifying hydraulic property layering within an unconfined aquifer and the underlying confining unit were assessed. The hydraulic properties of lithologic units within the unconfined aquifer and confining unit were computed by analyzing the aquifer-test data using radial, axisymmetric two-dimensional (2D) flow. Time-varying recharge to the unconfined aquifer and pumping from the confined Upper Floridan aquifer (USA) were simulated using 3D flow. Conceptual flow models were developed by gradually reducing the number of lithologic units in the unconfined aquifer and confining unit by calculating composite hydraulic properties for the simplified lithologic units. Composite hydraulic properties were calculated using either thickness-weighted averages or inverse modeling using regression-based parameter estimation. No significant residuals were simulated when all lithologic units comprising the unconfined aquifer were simulated as one layer. The largest residuals occurred when the unconfined aquifer and confining unit were aggregated into a single layer (quasi-3D), with residuals over 100% for the leakage rates to the confined aquifer and the heads in the confining unit. Residuals increased with contrasts in vertical hydraulic conductivity between the unconfined aquifer and confining unit. Residuals increased when the constant-head boundary at the bottom of the Upper Floridan aquifer was replaced with a no-flow boundary.

  17. Comparison of hydraulic conductivities for a sand and gravel aquifer in southeastern Massachusetts, estimated by three methods

    USGS Publications Warehouse

    Warren, L.P.; Church, P.E.; Turtora, Michael

    1996-01-01

    Hydraulic conductivities of a sand and gravel aquifer were estimated by three methods: constant- head multiport-permeameter tests, grain-size analyses (with the Hazen approximation method), and slug tests. Sediment cores from 45 boreholes were undivided or divided into two or three vertical sections to estimate hydraulic conductivity based on permeameter tests and grain-size analyses. The cores were collected from depth intervals in the screened zone of the aquifer in each observation well. Slug tests were performed on 29 observation wells installed in the boreholes. Hydraulic conductivities of 35 sediment cores estimated by use of permeameter tests ranged from 0.9 to 86 meters per day, with a mean of 22.8 meters per day. Hydraulic conductivities of 45 sediment cores estimated by use of grain-size analyses ranged from 0.5 to 206 meters per day, with a mean of 40.7 meters per day. Hydraulic conductivities of aquifer material at 29 observation wells estimated by use of slug tests ranged from 0.6 to 79 meters per day, with a mean of 32.9 meters per day. The repeatability of estimated hydraulic conductivities were estimated to be within 30 percent for the permeameter method, 12 percent for the grain-size method, and 9.5 percent for the slug test method. Statistical tests determined that the medians of estimates resulting from the slug tests and grain-size analyses were not significantly different but were significantly higher than the median of estimates resulting from the permeameter tests. Because the permeameter test is the only method considered which estimates vertical hydraulic conductivity, the difference in estimates may be attributed to vertical or horizontal anisotropy. The difference in the average hydraulic conductivities estimated by use of each method was less than 55 percent when compared to the estimated hydraulic conductivity determined from an aquifer test conducted near the study area.

  18. Hydrologic properties of coal-beds in the Powder River Basin, Montana. II. Aquifer test analysis

    USGS Publications Warehouse

    Weeks, E.P.

    2005-01-01

    A multiple well aquifer test to determine anisotropic transmissivity was conducted on a coal-bed in the Powder River Basin, southeastern Montana, as part of a multidisciplinary investigation to determine hydrologic conditions of coal-beds in the area. For the test, three wells were drilled equidistant from and at different angles to a production well tapping the Flowers-Goodale coal seam, a 7.6-m thick seam confined at a depth of about 110 m. The test was conducted by air-lift pumping for 9 h, and water levels were monitored in the three observation wells using pressure transducers. Drawdown data collected early in the test were affected by interporosity flow between the coal fracture network and the matrix, but later data were suitable to determine aquifer anisotropy, as the slopes of the late-time semilog time-drawdown curves are nearly identical, and the zero-drawdown intercepts are different. The maximum transmissivity, trending N87??E, is 14.9 m2/d, and the minimum transmissivity 6.8 m2/d, giving an anisotropy ratio of 2.2:1. Combined specific storage of the fractures and matrix is 2??10 -5/m, and of the fracture network alone 5??10-6/m. The principal direction of the anisotropy tensor is not aligned with the face cleats, but instead is aligned with another fracture set and with dominant east-west tectonic compression. Results of the test indicate that the Flowers-Goodale coal-bed is more permeable than many coals in the Powder River Basin, but the anisotropy ratio and specific storage are similar to those found for other coal-beds in the basin.

  19. Summary of Aquifer Test Data for Arkansas - 1940-2006

    USGS Publications Warehouse

    Pugh, Aaron L.

    2008-01-01

    As demands on Arkansas's ground water continue to increase, decision-makers need all available information to ensure the sustainability of this important natural resource. From 1940 through 2006, the U.S. Geological Survey has conducted over 300 aquifer tests in Arkansas. Much of these data never have been published. This report presents the results from 206 of these aquifer tests from 21 different hydrogeologic units spread across 51 Arkansas counties. Ten of the hydrogeologic units are within the Atlantic Plain of Arkansas and consist mostly of unconsolidated and semi-consolidated deposits. The remaining 11 units are within the Interior Highlands consisting mainly of consolidated rock. Descriptive statistics are reported for each hydrologic unit with two or more tests, including the mean, minimum, median, maximum and standard deviation values for specific capacity, transmissivity, hydraulic conductivity, and storage coefficient. Hydraulic conductivity values for the major water-bearing hydrogeologic units are estimated because few conductivity values are recorded in the original records. Nearly all estimated hydraulic conductivity values agree with published hydraulic conductivity values based on the hydrogeologic unit material types. Similarly, because few specific capacity values were available in the original aquifer test records, specific capacity values are estimated for individual wells.

  20. Assessment of spatial distrilbution of porosity and aquifer geohydraulic parameters in parts of the Tertiary - Quaternary hydrogeoresource of south-eastern Nigeria

    NASA Astrophysics Data System (ADS)

    George, N. J.; Akpan, A. E.; Akpan, F. S.

    2017-12-01

    An integrated attempt exploring information deduced from extensive surface resistivity study in three Local Government Areas of Akwa Ibom State, Nigeria and data from hydrogeological sources obtained from water boreholes have been explored to economically estimate porosity and coefficient of permeability/hydraulic conductivity in parts of the clastic Tertiary - Quaternary sediments of the Niger Delta region. Generally, these parameters are predominantly estimated from empirical analysis of core samples and pumping test data generated from boreholes in the laboratory. However, this analysis is not only costly and time consuming, but also limited in areal coverage. The chosen technique employs surface resistivity data, core samples and pumping test data in order to estimate porosity and aquifer hydraulic parameters (transverse resistance, hydraulic conductivity and transmissivity). In correlating the two sets of results, Porosity and hydraulic conductivity were observed to be more elevated near the riverbanks. Empirical models utilising Archie's, Waxman-Smits and Kozeny-Carman Bear relations were employed characterising the formation parameters with wonderfully deduced good fits. The effect of surface conduction occasioned by clay usually disregarded or ignored in Archie's model was estimated to be 2.58 × 10-5 Siemens. This conductance can be used as a corrective factor to the conduction values obtained from Archie's equation. Interpretation aided measures such as graphs, mathematical models and maps which geared towards realistic conclusions and interrelationship between the porosity and other aquifer parameters were generated. The values of the hydraulic conductivity estimated from Waxman-Smits model was approximately 9.6 × 10-5m/s everywhere. This revelation indicates that there is no pronounced change in the quality of the saturating fluid and the geological formations that serve as aquifers even though the porosities were varying. The deciphered parameter relations can be used to estimate geohydraulic parameters in other locations with little or no borehole data.

  1. Testing the usefulness of 222Rn to complement conventional hydrochemical data to trace groundwater provenance in complex multi-layered aquifers. Application to the Úbeda aquifer system (Jaén, SE Spain).

    PubMed

    Ortega, L; Manzano, M; Rodríguez-Arévalo, J

    2017-12-01

    The Úbeda aquifer system is a multi-layered aquifer intensively exploited for irrigation. It covers 1100km 2 and consists of piled up sedimentary aquifer and aquitard layers from Triassic sandstones and clays at the bottom, to Jurassic carbonates (main exploited layer) in the middle, and Miocene sandstones and marls at the top. Flow network modification by intense exploitation and the existence of deep faults favour vertical mixing of waters from different layers and with distinct chemical composition. This induces quality loss and fosters risk of quantity restrictions. To support future groundwater abstraction management, a hydrogeochemical (major and some minor solutes) and isotopic ( 222 Rn) study was performed to identify the chemical signatures of the different layers and their mixing proportions in mixed samples. The study of 134 groundwater samples allowed a preliminary identification of hydrochemical signatures and mixtures, but the existence of reducing conditions in the most exploited sector prevents the utility of sulphate as a tracer of Triassic groundwater in the Jurassic boreholes. The potential of 222 Rn to establish isotopic signatures and to trace groundwater provenance in mixtures was tested. 222 Rn was measured in 48 samples from springs and boreholes in most aquifer layers. At first, clear correlations were observed between 222 Rn, Cl and SO 4 in groundwater. Afterwards, very good correlations were observed between 222 Rn and the chemical facies of the different layers established with End Member Mixing Analysis (EMMA). Using 222 Rn as part of the signatures, EMMA helped to identify end-member samples, and to quantify the mixing proportions of water from the Triassic and the Deep Miocene layers in groundwater pumped by deep agricultural wells screened in the Jurassic. The incorporation of 222 Rn to the study also allowed identifying the impact of irrigation returns through the association of moderate NO 3 , Cl, and Br contents with very low 222 Rn activities. Copyright © 2017. Published by Elsevier B.V.

  2. Flow to partially penetrating wells in unconfined heterogeneous aquifers: Mean head and interpretation of pumping tests

    NASA Astrophysics Data System (ADS)

    Dagan, G.; Lessoff, S. C.

    2011-06-01

    A partially penetrating well of length Lw and radius Rw starts to pump at constant discharge Qw at t = 0 from an unconfined aquifer of thickness D. The aquifer is of random and stationary conductivity characterized by KG (geometric mean), σY2 (log conductivity variance), and I and Iv (the horizontal and vertical integral scales). The flow problem is solved under a few simplifying assumptions commonly adopted in the literature for homogeneous media: Rw/Lw ≪ 1, linearization of the free surface condition, and constant drainable porosity n. Additionally, it is assumed that Rw/I < 1 and Lw/Iv ≫ 1 (to simplify the well boundary conditions) and that a first-order approximation in σY2 (extended to finite σY2 on a conjectural basis) is adopted. The solution is obtained for the mean head field and the associated water table equation. The main result of the analysis is that the flow domain can be divided into three zones for : (1) the neighborhood of the well R ≪ I, where = (Qw/LwKA)h0(R, z, tKefuv/nD), with h0 being the zero-order solution pertaining to a homogeneous and isotropic aquifer, KA being the conductivity arithmetic mean, and Kefuv being the effective vertical conductivity in mean uniform flow, (2) an exterior zone R ⪆ I in which ?H? = (Qw/LwKefuh)h0(R?, z, tKefuv/nD), with Kefuh being the horizontal effective conductivity, and (3) an intermediate zone in which the solution requires a few numerical quadratures, not carried out here. The application to pumping tests reveals that identification of the aquifer parameters for homogeneous and anisotropic aquifers by commonly used methods can be applied for the drawdown measured in an observation well of length Low?Iv (to ensure exchange of space and ensemble head averages) in the second zone in order to identify Kefuh, Kefuv, and n. In contrast, the use of the drawdown in the well (first zone) leads to an overestimation of Kefuh by the factor KA/Kefuh.

  3. Aquifer-test evaluation and potential effects of increased ground-water pumpage at the Stovepipe Wells Hotel area, Death Valley National Monument, California

    USGS Publications Warehouse

    Woolfenden, L.R.; Martin, Peter; Baharie, Brian

    1988-01-01

    Ground-water use in the Stovepipe Wells Hotel area in Death Valley National Monument is expected to increase significantly if the nonpotable, as well as potable, water supply is treated by reverse osmosis. During the peak tourist season, October through March, ground-water pumpage could increase by 37,500 gallons per day, or 76%. The effects of this additional pumpage on water levels in the area, particularly near a strand of phreatophytes about 10,000 feet east of the well field, are of concern. In order to evaluate the effects of increased pumpage on water levels in the Stovepipe Wells Hotel area well field, two aquifer tests were performed at the well field to determine the transmissivity and storage coefficients of the aquifer. Analysis of the aquifer test determined that a transmissivity of 1,360 feet squared per day was representative of the aquifer. The estimated value of transmissivity and the storage-coefficient values that are representative of confined (1.2 x .0004) and unconfined (0.25) conditions were used in the Theis equation to calculate the additional drawdown that might occur after 1, 10, and 50 years of increased pumpage. The drawdown calculated by using the lower storage-coefficient value represents the maximum additional drawdown that might be expected from the assumed increase in pumpage; the drawdown calculated by using the higher storage-coefficient value represents the minimum additional drawdown. Calculated additional drawdowns after 50 years of pumping range from 7.8 feet near the pumped well to 2.4 feet at the phreatophyte stand assuming confined conditions, and from 5.7 feet near the pumped well to 0.3 foot at the phreatophyte stand assuming unconfined conditions. Actual drawdowns probably will be somewhere between these values. Drawdowns measured in observation wells during 1973-85, in response to an average pumpage of 34,200 gallons per day at the Stovepipe Wells Hotel well field, are similar to the drawdowns calculated by the Theis equation for the assumed increase in pumpage. (Author 's abstract)

  4. Current approaches for the assessment of in situ biodegradation.

    PubMed

    Bombach, Petra; Richnow, Hans H; Kästner, Matthias; Fischer, Anko

    2010-04-01

    Considering the high costs and technical difficulties associated with conventional remediation strategies, in situ biodegradation has become a promising approach for cleaning up contaminated aquifers. To verify if in situ biodegradation of organic contaminants is taking place at a contaminated site and to determine if these processes are efficient enough to replace conventional cleanup technologies, a comprehensive characterization of site-specific biodegradation processes is essential. In recent years, several strategies including geochemical analyses, microbial and molecular methods, tracer tests, metabolite analysis, compound-specific isotope analysis, and in situ microcosms have been developed to investigate the relevance of biodegradation processes for cleaning up contaminated aquifers. In this review, we outline current approaches for the assessment of in situ biodegradation and discuss their potential and limitations. We also discuss the benefits of research strategies combining complementary methods to gain a more comprehensive understanding of the complex hydrogeological and microbial interactions governing contaminant biodegradation in the field.

  5. Spatial scale analysis in geophysics - Integrating surface and borehole geophysics in groundwater studies

    USGS Publications Warehouse

    Paillet, Frederick L.; Singhroy, V.H.; Hansen, D.T.; Pierce, R.R.; Johnson, A.I.

    2002-01-01

    Integration of geophysical data obtained at various scales can bridge the gap between localized data from boreholes and site-wide data from regional survey profiles. Specific approaches to such analysis include: 1) comparing geophysical measurements in boreholes with the same measurement made from the surface; 2) regressing geophysical data obtained in boreholes with water-sample data from screened intervals; 3) using multiple, physically independent measurements in boreholes to develop multivariate response models for surface geophysical surveys; 4) defining subsurface cell geometry for most effective survey inversion methods; and 5) making geophysical measurements in boreholes to serve as independent verification of geophysical interpretations. Integrated analysis of surface electromagnetic surveys and borehole geophysical logs at a study site in south Florida indicates that salinity of water in the surficial aquifers is controlled by a simple wedge of seawater intrusion along the coast and by a complex pattern of upward brine seepage from deeper aquifers throughout the study area. This interpretation was verified by drilling three additional test boreholes in carefully selected locations.

  6. Inter-aquifer Dynamics in and Near a Confining Unit Window in Shelby County, Tennessee, USA

    NASA Astrophysics Data System (ADS)

    Gentry, R. W.; McKay, L. D.; Larsen, D.; Carmichael, J. K.; Solomon, D. K.; Thonnard, N.; Anderson, J. L.

    2003-12-01

    An interdisplinary research team is investigating the interaction between the surficial alluvial aquifer and the deeper confined Memphis aquifer in the Memphis area, Shelby County, Tennessee. Previous research has identified a window in the clay-rich, upper Claiborne confining unit that separates the two aquifers near a closed municipal landfill in east-central Shelby County, an area undergoing rapid urbanization. For this investigation, a combination of environmental tracers (tritium/helium-3), major and trace ion geochemistry, hydraulic response testing, measurement of hydraulic gradients, and groundwater flow modeling is being used to quantify recharge of young water from the alluvial aquifer through the window to the Memphis aquifer. The research will provide results to better understand how windows were formed and how they influence recharge and water quality in otherwise confined parts of the Memphis aquifer downdip of its outcrop/subcrop area. Examination of continuous core samples and geophysical logs from wells installed for the study using Rotasonic drilling methods confirmed the existence of a sand-dominated window that may be as much as 1 km in diameter in the upper Claiborne confining unit. The upper Claiborne confining unit is 15 to 20 m thick in most of the study area and is overlain by a 10 to 12 m thick alluvial aquifer. The window is interpreted to have formed as a result of depositional and incisional processes in an Eocene-age deltaic system. Hydraulic gradients of several feet exist vertically between the alluvial and Memphis aquifers within the window, indicating downward flow. Groundwater age-dates from tritium/helium-3 analyses indicate that groundwater in the window at the depth of the base of the surrounding confining unit (approximately 30 m) has an apparent age of 19.8 years, which confirms the occurrence of downward flow. Young groundwater age dates (less than 32 years) also were obtained from wells in the Memphis aquifer at confined sites downgradient of the window, suggesting that a plume of young water is spreading outwards from the window and mixing with the older Memphis aquifer water. Preliminary inverse modeling of the site using a genetic algorithm coupled with a central finite difference flow model indicates a probable steady-state downward flux of about 12,000 m3/d through the window. Collection and analysis of additional groundwater samples are planned to examine geochemical conditions in the confining unit and in the Memphis aquifer upgradient of the window. These analyses will aid in developing a final conceptual model and in subsequent numerical modeling of mixing of the young recharge water with the older Memphis aquifer water.

  7. A unique approach to estimating lateral anisotropy in complex geohydrologic environments

    USGS Publications Warehouse

    Halford, K.J.; Campbell, B.

    2004-01-01

    Aquifers in fractured rock or karstic settings are likely to have anisotropic transmissivity distributions. Aquifer tests that are performed in these settings also we frequently affected by leakage from adjacent confining units. Finite-difference models such as MODFLOW are convenient tools for estimating the hydraulic characteristics of the stressed aquifer and adjacent confining units but are poor tools for the estimation of lateral anisotropy. This limitation of finite-difference methods can be overcome by application of the spin method, a technique whereby the positions of the observation wells are rotated about the production well to estimate anisotropy and orientation. Formal parameter estimation is necessary to analyze aquifer tests because of the number of parameters that we estimated. As a test, transmissivity, anisotropy, and orientation were successfully estimated for a simple hypothetical problem with known properties. The technique also was applied to estimate hydraulic properties of the Santee Limestone/Black Mingo (SL/BM) aquifer and a leaky confining unit beneath Charleston, South Carolina. A 9-day aquifer test with an average discharge of 644 1/min was analyzed numerically. Drawdowns in the SL/BM aquifer and confining unit were simulated with a 12-layer MODFLOW model that was discretized into 81 rows of 81 columns. Simulated drawdowns at seven observation wells that ranged from 23 to 2700 m from the production well were matched to measured drawdowns. Transmissivity estimated along the minor axis ranged from 10 to 15 m2/day and along the major axis ranged from 80 to 100 m2/day. The major axis of transmissivity was oriented along compass heading 116?? (degrees clockwise from north), which agrees with geologic interpretations. Vertical hydraulic conductivity and specific storage estimates for the overlying confining unit were 4 ?? 10-5m/day and 2 ?? 10-4 1/m, respectively. ?? 2004 International Association of Hydraulic Engineering and Research.

  8. Hydrogeologic reconnaissance of the Swope Oil Superfund site and vicinity, Camden and Burlington counties, New Jersey

    USGS Publications Warehouse

    Barton, G.J.; Krebs, M.M.

    1990-01-01

    Groundwater beneath a former chemical reclamation facility in New Jersey is contaminated with metals and organic compounds. The off-site migration of these compounds has not been studied; however, a nearby public-supply well is contaminated, and a public-supply well 1,400 ft downgradient from the site may be threatened. The study area, in the New Jersey part of the Atlantic Coastal Plain, is underlain by alluvial deposits composed of gravel, sand, silt, and clay. These deposits comprise the water table aquifer, the confining units, and the confined aquifer throughout the study area. The water table beneath the Swope Oil Superfund site is approximately 17 ft below sea level and groundwater levels throughout the study area are below the stage of the Delaware River. The aquifer system is recharged by precipitation, leakage of water through confining units, and the water induced from the Delaware River. Five public supply-well fields, primarily adjacent to the Delaware River, and four waste disposal sites with observation well networks are located in the study area. Both the water table and confined aquifers are contaminated in several locations. The concentration of metals and/or purgeable organic compounds in more than 20 wells exceeds the U.S. Environmental Protection Agency primary drinking-water standard and the New Jersey Department of Environmental Protection recommended drinking water criteria. Selected data from wells and test borings are presented, including well construction details; drillers ', geologists ', and geophysical logs; water levels; specific-capacity and slug test data; and chemical analysis of groundwater samples. (USGS)

  9. Optimal remediation of unconfined aquifers: Numerical applications and derivative calculations

    NASA Astrophysics Data System (ADS)

    Mansfield, Christopher M.; Shoemaker, Christine A.

    1999-05-01

    This paper extends earlier work on derivative-based optimization for cost-effective remediation to unconfined aquifers, which have more complex, nonlinear flow dynamics than confined aquifers. Most previous derivative-based optimization of contaminant removal has been limited to consideration of confined aquifers; however, contamination is more common in unconfined aquifers. Exact derivative equations are presented, and two computationally efficient approximations, the quasi-confined (QC) and head independent from previous (HIP) unconfined-aquifer finite element equation derivative approximations, are presented and demonstrated to be highly accurate. The derivative approximations can be used with any nonlinear optimization method requiring derivatives for computation of either time-invariant or time-varying pumping rates. The QC and HIP approximations are combined with the nonlinear optimal control algorithm SALQR into the unconfined-aquifer algorithm, which is shown to compute solutions for unconfined aquifers in CPU times that were not significantly longer than those required by the confined-aquifer optimization model. Two of the three example unconfined-aquifer cases considered obtained pumping policies with substantially lower objective function values with the unconfined model than were obtained with the confined-aquifer optimization, even though the mean differences in hydraulic heads predicted by the unconfined- and confined-aquifer models were small (less than 0.1%). We suggest a possible geophysical index based on differences in drawdown predictions between unconfined- and confined-aquifer models to estimate which aquifers require unconfined-aquifer optimization and which can be adequately approximated by the simpler confined-aquifer analysis.

  10. Recovery of injected freshwater to differentiate fracture flow in a low-permeability brackish aquifer

    NASA Astrophysics Data System (ADS)

    Miotliński, Konrad; Dillon, Peter J.; Pavelic, Paul; Cook, Peter G.; Page, Declan W.; Levett, Kerry

    2011-10-01

    SummaryA low-permeability weathered siltstone-sandstone aquifer containing brackish water was investigated to measure recoverability of injected freshwater with the aim of determining the significance of secondary porosity in contributing to groundwater flow and transport. Examination of the core, borehole geophysics, Radon-222, electromagnetic flowmeter (EMF) profiles and step-drawdown pumping tests did not identify whether fractures contribute to groundwater flow. A number of injection and recovery tests lasting from 3 days to 3 months using potable water showed a large degree of mixing with native groundwater. Withdrawal greater than 12-17% of the injected volume resulted in recovered water containing more native groundwater than injected water. A finite element solute transport model was set up to reproduce the observed salinity in recovered water. Without the inclusion of discrete fractures in the model it was not possible to get a fit between the observed and modelled salinity of recovered water within a realistic range of dispersivity values. The model was subsequently verified by using data from long-term injection and recovery trials. This evaluation of mixing conclusively demonstrated that the aquifer behaved as a fractured rock aquifer and not as an aquifer with primary porosity alone. Therefore, aquifer storage and recovery can be a very useful hydrogeological method to identify the occurrence of fracture flow in aquifers where there is a measurable concentration difference between the injected water and ambient groundwater.

  11. MISSISSIPPI EMBAYMENT AQUIFER SYSTEM IN MISSISSIPPI: GEOHYDROLOGIC DATA COMPILATION FOR FLOW MODEL SIMULATION.

    USGS Publications Warehouse

    Arthur, J.K.; Taylor, R.E.

    1986-01-01

    As part of the Gulf Coast Regional Aquifer System Analysis (GC RASA) study, data from 184 geophysical well logs were used to define the geohydrologic framework of the Mississippi embayment aquifer system in Mississippi for flow model simulation. Five major aquifers of Eocene and Paleocene age were defined within this aquifer system in Mississippi. A computer data storage system was established to assimilate the information obtained from the geophysical logs. Computer programs were developed to manipulate the data to construct geologic sections and structure maps. Data from the storage system will be input to a five-layer, three-dimensional, finite-difference digital computer model that is used to simulate the flow dynamics in the five major aquifers of the Mississippi embayment aquifer system.

  12. Completion summary for borehole USGS 136 near the Advanced Test Reactor Complex, Idaho National Laboratory, Idaho

    USGS Publications Warehouse

    Twining, Brian V.; Bartholomay, Roy C.; Hodges, Mary K.V.

    2012-01-01

    In 2011, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, cored and completed borehole USGS 136 for stratigraphic framework analyses and long-term groundwater monitoring of the eastern Snake River Plain aquifer at the Idaho National Laboratory. The borehole was initially cored to a depth of 1,048 feet (ft) below land surface (BLS) to collect core, open-borehole water samples, and geophysical data. After these data were collected, borehole USGS 136 was cemented and backfilled between 560 and 1,048 ft BLS. The final construction of borehole USGS 136 required that the borehole be reamed to allow for installation of 6-inch (in.) diameter carbon-steel casing and 5-in. diameter stainless-steel screen; the screened monitoring interval was completed between 500 and 551 ft BLS. A dedicated pump and water-level access line were placed to allow for aquifer testing, for collecting periodic water samples, and for measuring water levels.Geophysical and borehole video logs were collected after coring and after the completion of the monitor well. Geophysical logs were examined in conjunction with the borehole core to describe borehole lithology and to identify primary flow paths for groundwater, which occur in intervals of fractured and vesicular basalt.A single-well aquifer test was used to define hydraulic characteristics for borehole USGS 136 in the eastern Snake River Plain aquifer. Specific-capacity, transmissivity, and hydraulic conductivity from the aquifer test were at least 975 gallons per minute per foot, 1.4 × 105 feet squared per day (ft2/d), and 254 feet per day, respectively. The amount of measureable drawdown during the aquifer test was about 0.02 ft. The transmissivity for borehole USGS 136 was in the range of values determined from previous aquifer tests conducted in other wells near the Advanced Test Reactor Complex: 9.5 × 103 to 1.9 × 105 ft2/d.Water samples were analyzed for cations, anions, metals, nutrients, total organic carbon, volatile organic compounds, stable isotopes, and radionuclides. Water samples from borehole USGS 136 indicated that concentrations of tritium, sulfate, and chromium were affected by wastewater disposal practices at the Advanced Test Reactor Complex. Depth-discrete groundwater samples were collected in the open borehole USGS 136 near 965, 710, and 573 ft BLS using a thief sampler; on the basis of selected constituents, deeper groundwater samples showed no influence from wastewater disposal at the Advanced Test Reactor Complex.

  13. Effects of highway-deicer application on ground-water quality in a part of the Calumet Aquifer, northwestern Indiana

    USGS Publications Warehouse

    Watson, Lee R.; Bayless, E. Randall; Buszka, Paul M.; Wilson, John T.

    2002-01-01

    The effects of highway-deicer application on ground-water quality were studied at a site in northwestern Indiana using a variety of geochemical indicators. Site characteristics such as high snowfall rates; large quantities of applied deicers; presence of a high-traffic highway; a homogeneous, permeable, and unconfined aquifer; a shallow water table; a known ground-water-flow direction; and minimal potential for other sources of chloride and sodium to complicate source interpretation were used to select a study area where ground water was likely to be affected by deicer application. Forty-three monitoring wells were installed in an unconfined sand aquifer (the Calumet aquifer) near Beverly Shores in northwestern Indiana. Wells were installed along two transects that approximately paralleled groundwater flow in the Calumet aquifer and crossed US?12. US?12 is a highway that receives Indiana?s highest level of maintenance to maintain safe driving conditions. Ground-water quality and water-level data were collected from the monitoring wells, and precipitation and salt-application data were compiled from 1994 through 1997. The water-quality data indicated that chloride was the most easily traced indicator of highway deicers in ground water. Concentration ratios of chloride to iodide and chloride to bromide and Stiff diagrams of major element concentrations indicated that the principal source of chloride and sodium in ground water from the uppermost one-third to one-half of the Calumet relative electromagnetic conductivity defined a distinct plume of deicer-affected water in the uppermost 8 feet of aquifer at about 9 feet horizontally from the paved roadway edge and a zone of higher conductivity than background in the lower one-third of the aquifer. Chloride and sodium in the deep parts of the aquifer originated from natural sources. Chloride and sodium from highway deicers were present in the aquifer throughout the year. The highest concentrations of chloride and sodium in ground water were determined in samples collected during the spring and summer from wells open to the water table within about 9 feet of the highway. Chloride concentrations in ground water that were attributable to highway deicers also were found in tested wells about 400 feet downgradient from US?12 during the fall and winter and at greater depths than in wells closer to US?12. Chloride concentrations exceeded the U.S. Environmental Protection Agency?s (USEPA) secondary maximum contaminant level of 250 milligrams per liter for drinking water at seven wells downgradient from the highway during late winter, spring, and summer samplings. The chloride standard was exceeded only in water from wells with total depths that are less than about 10 feet below land surface. Sodium concentrations in water periodically exceeded the USEPA drinking-water equivalency level of 20 milligrams per liter in both the uppermost (deicer affected) and lower one-thirds of the aquifer. Sodium concentrations in ground water downgradient from US?12 and in the upper 5 feet of the aquifer also occasionally exceeded drinking-water standards for sodium (160 milligrams per liter) as set by the State of Florida and a standard for taste (200 milligrams per liter) as set by the World Health Organization. Dispersion was identified by analysis of aquifer-test data, isotopic dating of ground water, and water-quality data to be the process most responsible for reducing concentrations of highway deicers in the aquifer. Chemical analyses of the sand composing the aquifer indicated that cation exchange decreased the mass of deicer-related sodium in ground water, although the sand has a limited capacity to sustain the process. Automated daily measurements of specific conductance, correlated to chloride concentrations, indicated that some deicer is retained in the aquifer near the highway throughout the entire year and acts as a continuous chloride source for ground water. Peak concentrations of

  14. Ground-water levels in aquifers used for residential supply, Campton Township, Kane County, Illinois

    USGS Publications Warehouse

    Kay, Robert T.; Kraske, Kurt A.

    1996-01-01

    The U.S. Geological Survey, in cooperation with the Campton Township Board of Trustees, measured water levels in the aquifers used for residential supply in Campton Township, Kane County, Illinois. Aquifers used for residential supply are the shallow and deep aquifers in the glacial drift, composed of unconsolidated sand and gravels; the Alexandrian-Maquoketa aquifer, composed of dolomite and shale of the Alexandrian Series and the Maquoketa Group; the Galena-Platteville aquifer, composed of dolomite of the Platteville and Galena Groups; and the Ancell aquifer, composed of sandstones of the Glenwood Formation and the St. Peter Sanstone. Water-level altitudes in the shallow drift aquifers generally follow surface topography. Analysis of water-level data does not clearly indicate overutilization of these aquifers. Water-level altitudes in the deep drift aquifers decrease from west to east. Comparison of historical depth to water measurements with current (1995) measurements indicates large decreases in water levels in some areas. The deep drift aquifers may be overutilized at these locations. Water-level altitudes in the Alexandrian-Maquoketa aquifer generally decrease from west to east. The potentiometric surface of the aquifer follows the bedrock-surface topography in some locations. Localized low water-level altitudes and large decreases in water levels indicate the Alexandrian-Maquoketa aquifer is overutilized in several areas. Water-level altitudes in the wells finished in the Galena- Platteville aquifer vary by more than 300 feet. Large decreases in water levels in wells finished in the Galena-Platteville aquifer indicate the Galena-Platteville and Alexandrian-Maquoketa aquifers are overutilized in the northern part of the township. Water-level altitudes in the wells finished in the Ancell aquifer are also highly variable. There is no indication that the Ancell aquifer is overutilized.

  15. OPTIMIZING BTEX BIODEGRADATION UNDER DENITRIFYING CONDITIONS

    EPA Science Inventory

    Laboratory tests were conducted to determine optimum conditions for benzene, toluene, ethylbenzene, and xylene (collectively known as BTEX) biodegradation by aquifer microorganisms under denitrifying conditions. Microcosms, constructed with aquifer samples from Traverse City, Mic...

  16. A Semianalytical Model for Pumping Tests in Finite Heterogeneous Confined Aquifers With Arbitrarily Shaped Boundary

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Dai, Cheng; Xue, Liang

    2018-04-01

    This study presents a Laplace-transform-based boundary element method to model the groundwater flow in a heterogeneous confined finite aquifer with arbitrarily shaped boundaries. The boundary condition can be Dirichlet, Neumann or Robin-type. The derived solution is analytical since it is obtained through the Green's function method within the domain. However, the numerical approximation is required on the boundaries, which essentially renders it a semi-analytical solution. The proposed method can provide a general framework to derive solutions for zoned heterogeneous confined aquifers with arbitrarily shaped boundary. The requirement of the boundary element method presented here is that the Green function must exist for a specific PDE equation. In this study, the linear equations for the two-zone and three-zone confined aquifers with arbitrarily shaped boundary is established in Laplace space, and the solution can be obtained by using any linear solver. Stehfest inversion algorithm can be used to transform it back into time domain to obtain the transient solution. The presented solution is validated in the two-zone cases by reducing the arbitrarily shaped boundaries to circular ones and comparing it with the solution in Lin et al. (2016, https://doi.org/10.1016/j.jhydrol.2016.07.028). The effect of boundary shape and well location on dimensionless drawdown in two-zone aquifers is investigated. Finally the drawdown distribution in three-zone aquifers with arbitrarily shaped boundary for constant-rate tests (CRT) and flow rate distribution for constant-head tests (CHT) are analyzed.

  17. Aquifer pumping test report for the burn site groundwater area of concern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skelly, Michael; Ferry, Robert

    The Aquifer Pumping Test Report for the Burn Site Groundwater (BSG) Area of Concern is being submitted by National Technology and Engineering Solutions of Sandia, LLC and the U.S. Department of Energy (DOE)/National Nuclear Security Administration to describe the results of the aquifer pumping test program and related field activities that were completed at the BSG Area of Concern. This report summarizes the results of the field work and data analyses, and is being submitted to the New Mexico Environment Department (NMED) Hazardous Waste Bureau, as required by the April 14, 2016 letter, Summary of Agreements and Proposed Milestones Pursuantmore » to the Meeting of July 20, 2015, (NMED April 2016).« less

  18. Hydrogeology and water quality of the Floridan aquifer system and effect of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Hunter Army Airfield, Chatham County, Georgia

    USGS Publications Warehouse

    Clarke, John S.; Williams, Lester J.; Cherry, Gregory C.

    2010-01-01

    Test drilling and field investigations, conducted at Hunter Army Airfield (HAAF), Chatham County, Georgia, during 2009, were used to determine the geologic, hydraulic, and water-quality characteristics of the Floridan aquifer system and to evaluate the effect of Lower Floridan aquifer (LFA) pumping on the Upper Floridan aquifer (UFA). Field investigation activities included (1) constructing a 1,168-foot (ft) test boring and well completed in the LFA, (2) collecting drill cuttings and borehole geophysical logs, (3) collecting core samples for analysis of vertical hydraulic conductivity and porosity, (4) conducting flowmeter and packer tests in the open borehole within the UFA and LFA, (5) collecting depth-integrated water samples to assess basic ionic chemistry of various water-bearing zones, and (6) conducting aquifer tests in the new LFA well and in an existing UFA well to determine hydraulic properties and assess interaquifer leakage. Using data collected at the site and in nearby areas, model simulation was used to quantify the effects of interaquifer leakage on the UFA and to determine the amount of pumping reduction required in the UFA to offset drawdown resulting from the leakage. Borehole-geophysical and flowmeter data indicate the LFA at HAAF consists of limestone and dolomitic limestone between depths of 703 and 1,080 ft, producing water from six major permeable zones: 723-731; 768-785; 818-837; 917-923; 1,027-1,052; and 1,060-1,080 ft. Data from a flowmeter survey, conducted at a pumping rate of 748 gallons per minute (gal/min), suggest that the two uppermost zones contributed 469 gal/min or 62.6 percent of the total flow during the test. The remaining four zones contributed from 1.7 to 18 percent of the total flow. Grab water samples indicate that with the exception of fluoride, constituent concentrations in the LFA increased with depth; water from the deepest interval (1,075 ft) contained chloride and sulfate concentrations of 480 and 240 milligrams per liter (mg/L), respectively. These relatively high concentrations were interpreted to have little effect on the overall quality of the well because flowmeter results indicated that water from 1,060 to 1,080 ft contributed less than 2 percent of the total flow to the completed well. Results of a 72-hour aquifer test indicate that pumping a LFA well at a rate of 748 gal/min produced a drawdown response of 0.76 ft in a well completed in the UFA located 176 ft from the pumped well. A revised regional groundwater-flow model was used to simulate long-term (steady-state) leakage response of the UFA to pumping from the LFA and to estimate the equivalent amount of pumping from the UFA that would produce similar drawdown. Pumping the well at a rate of 748 gal/min (about 1 million gallons per day [Mgal/d]) resulted in a maximum simulated steady-state drawdown of 36.2 ft in the LFA and was greater than 1 ft over a 146 square-mile area. Simulated steady-state drawdown in the overlying UFA that resulted from interaquifer leakage was greater than 1 ft over a 141 square-mile area and was 2.03 ft at the pumped well. Flow to the pumped well was derived from increased lateral flow across the specified-head boundary (0.02 Mgal/d) and increased leakage from the UFA (0.52 Mgal/d), and by reductions in discharge to the Lower Floridan confining unit (0.53 Mgal/d) and to the lateral specified-head boundary (0.53 Mgal/d). Sixty-five percent of the leakage from the UFA occurred within 1 mile of the pumped well. This larger contribution results from a larger head gradient between the pumped well and the overlying aquifer in areas close to the pumped well. The Georgia Environmental Protection Division interim permitting strategy for the LFA requires simulation of (1) aquifer leakage from the UFA to LFA resulting from pumping the new LFA well, and (2) the equivalent rate of UFA pumping that induces the identical maximum drawdown in the UFA that would be expected as a result of pumping th

  19. Factors Affecting Specific-Capacity Tests and their Application--A Study of Six Low-Yielding Wells in Fractured-Bedrock Aquifers in Pennsylvania

    USGS Publications Warehouse

    Risser, Dennis W.

    2010-01-01

    This report by the U.S. Geological Survey, prepared in cooperation with the Pennsylvania Department of Environmental Protection, Bureau of Mining and Reclamation, evaluates factors affecting the application of specific-capacity tests in six low-yielding water wells in areas of coal mining or quarrying in Pennsylvania. Factors such as pumping rate, duration of pumping, aquifer properties, wellbore storage, and turbulent flow were assessed by theoretical analysis and by completing multiple well tests, selected to be representative of low-yielding household-supply wells in areas of active coal mining or quarrying. All six wells were completed in fractured-bedrock aquifers--five in coal-bearing shale, siltstone, sandstone, limestone, and coal of Pennsylvanian and Permian age and one in limestone of Cambrian age. The wells were pumped 24 times during 2007-09 at rates from 0.57 to 14 gallons per minute during tests lasting from 22 to 240 minutes. Geophysical logging and video surveys also were completed to determine the depth, casing length, and location of water-yielding zones in each of the test wells, and seasonal water-level changes were measured during 2007-09 by continuous monitoring at each well. The tests indicated that specific-capacity values were reproducible within about ? 20 percent if the tests were completed at the same pumping rate and duration. A change in pumping duration, pumping rate, or saturated aquifer thickness can have a substantial effect on the comparability of repeated tests. The largest effect was caused by a change in aquifer thickness in well YO 1222 causing specific capacity from repeated tests to vary by a factor of about 50. An increase in the duration of pumping from 60 to 180 minutes caused as much as a 62 percent decrease in specific capacity. The effect of differing pumping rates on specific capacity depends on whether or not the larger rate causes the water level in the well to fall below a major water-yielding zone; when this decline happened at well CA 462, specific capacity was reduced by about 63 percent. Estimates of the maximum yield for low-yielding wells that are computed by multiplying the available drawdown by the specific-capacity value may contain large errors if the wells were pumped at low rates that do not cause much water-level drawdown. The estimates of yield are likely to be too large because the effects of lowering the water level in the well below water-yielding zones have not been incorporated. Better yield estimates can be made by the use of step-drawdown tests or by over-pumping at a rate large enough to dewater most of the wellbore. The maximum well yield, after overpumping, can be estimated from the rate of water-level recovery or by subtracting the incremental rate of change of borehole storage at the end of the test from the pumping rate.

  20. Sensitivity of the Gravity Recovery and Climate Experiment (GRACE) to the complexity of aquifer systems for monitoring of groundwater

    NASA Astrophysics Data System (ADS)

    Katpatal, Yashwant B.; Rishma, C.; Singh, Chandan K.

    2018-05-01

    The Gravity Recovery and Climate Experiment (GRACE) satellite mission is aimed at assessment of groundwater storage under different terrestrial conditions. The main objective of the presented study is to highlight the significance of aquifer complexity to improve the performance of GRACE in monitoring groundwater. Vidarbha region of Maharashtra, central India, was selected as the study area for analysis, since the region comprises a simple aquifer system in the western region and a complex aquifer system in the eastern region. Groundwater-level-trend analyses of the different aquifer systems and spatial and temporal variation of the terrestrial water storage anomaly were studied to understand the groundwater scenario. GRACE and its field application involve selecting four pixels from the GRACE output with different aquifer systems, where each GRACE pixel encompasses 50-90 monitoring wells. Groundwater storage anomalies (GWSA) are derived for each pixel for the period 2002 to 2015 using the Release 05 (RL05) monthly GRACE gravity models and the Global Land Data Assimilation System (GLDAS) land-surface models (GWSAGRACE) as well as the actual field data (GWSAActual). Correlation analysis between GWSAGRACE and GWSAActual was performed using linear regression. The Pearson and Spearman methods show that the performance of GRACE is good in the region with simple aquifers; however, performance is poorer in the region with multiple aquifer systems. The study highlights the importance of incorporating the sensitivity of GRACE in estimation of groundwater storage in complex aquifer systems in future studies.

  1. Microbial succession and stimulation following a test well injection simulating CO2 leakage into shallow Newark Basin aquifers

    NASA Astrophysics Data System (ADS)

    Dueker, M.; Clauson, K.; Yang, Q.; Umemoto, K.; Seltzer, A. M.; Zakharova, N. V.; Matter, J. M.; Stute, M.; Takahashi, T.; Goldberg, D.; O'Mullan, G. D.

    2012-12-01

    Despite growing appreciation for the importance of microbes in altering geochemical reactions in the subsurface, the microbial response to geological carbon sequestration injections and the role of microbes in altering metal mobilization following leakage scenarios in shallow aquifers remain poorly constrained. A Newark Basin test well was utilized in field experiments to investigate patterns of microbial succession following injection of CO2 saturated water into isolated aquifer intervals. Additionally, laboratory mesocosm experiments, including microbially-active and inactive (autoclave sterilized) treatments, were used to constrain the microbial role in mineral dissolution, trace metal release, and gas production (e.g. hydrogen and methane). Hydrogen production was detected in both sterilized and unsterilized laboratory mesocosm treatments, indicating abiotic hydrogen production may occur following CO2 leakage, and methane production was detected in unsterilized, microbially active mesocosms. In field experiments, a decrease in pH following injection of CO2 saturated aquifer water was accompanied by mobilization of trace elements (e.g. Fe and Mn), the production of hydrogen gas, and increased bacterial cell concentrations. 16S ribosomal RNA clone libraries, from samples collected before and after the test well injection, were compared in an attempt to link variability in geochemistry to changes in aquifer microbiology. Significant changes in microbial composition, compared to background conditions, were found following the test well injection, including a decrease in Proteobacteria, and an increased presence of Firmicutes, Verrucomicrobia, Acidobacteria and other microbes associated with iron reducing and syntrophic metabolism. The concurrence of increased microbial cell concentration, and rapid microbial community succession, with increased concentrations of hydrogen gas suggests that abiotically produced hydrogen may serve as an ecologically-relevant energy source stimulating changes in aquifer microbial communities immediately following CO2 leakage.

  2. Combining Deterministic structures and stochastic heterogeneity for transport modeling

    NASA Astrophysics Data System (ADS)

    Zech, Alraune; Attinger, Sabine; Dietrich, Peter; Teutsch, Georg

    2017-04-01

    Contaminant transport in highly heterogeneous aquifers is extremely challenging and subject of current scientific debate. Tracer plumes often show non-symmetric but highly skewed plume shapes. Predicting such transport behavior using the classical advection-dispersion-equation (ADE) in combination with a stochastic description of aquifer properties requires a dense measurement network. This is in contrast to the available information for most aquifers. A new conceptual aquifer structure model is presented which combines large-scale deterministic information and the stochastic approach for incorporating sub-scale heterogeneity. The conceptual model is designed to allow for a goal-oriented, site specific transport analysis making use of as few data as possible. Thereby the basic idea is to reproduce highly skewed tracer plumes in heterogeneous media by incorporating deterministic contrasts and effects of connectivity instead of using unimodal heterogeneous models with high variances. The conceptual model consists of deterministic blocks of mean hydraulic conductivity which might be measured by pumping tests indicating values differing in orders of magnitudes. A sub-scale heterogeneity is introduced within every block. This heterogeneity can be modeled as bimodal or log-normal distributed. The impact of input parameters, structure and conductivity contrasts is investigated in a systematic manor. Furthermore, some first successful implementation of the model was achieved for the well known MADE site.

  3. Analysis of ground-water flow in the Catahoula aquifer system in the vicinity of Laurel and Hattiesburg, Mississippi

    USGS Publications Warehouse

    Halford, K.J.; Barber, N.L.

    1995-01-01

    The upper, middle, and lower Catahoula aquifers in the vicinity of the cites of Laurel and Hattiesburg in southern Mississippi are made up of irregular, discontinuous sand zones in the Catahoula Formation of Miocene age. In places thee three aquifers may be hydraulically well connected, and are referred to as the Catahoula aquifer system. Withdrawal from the Catahoula aquifers increased from 28 million gallons per day (Mgal/d) to 41 Mgal/d during 1970 to 1985, and decreased to 38 Mgal/d during 1990. Most withdrawal in the Laurel area is from the lower and middle Catahoula, and most withdrawal in the Hattiesburg area is from the middle and upper Catahoula aquifers. In the Laurel area, water levels in selected wells in the lower Catahoula aquifer declined at rates ranging from about 1 to 3.6 feet/ year until the late 1980's in response to the increase in pumping. A three-dimensional model was developed to represent ground-water flow in the Catahoula aquifers. Simulated water levels in the lower Catahoula aquifer, the layer most affected by pumping, were lowered from predevelopment levels as much as 130 feet in the Laurel area and 100 feet in the Hattiesburg area, according to the model analysis of 1992 conditions. Three scenarios of increased pumpage, for the period 1992-2020, were simulated. Under the low-growth scenario, water- level declines would be 20 feet or less below 1992 water levels in the middle and upper Catahoula aquifer in the Hattiesburg area, and about 60 feet in the lower Catahoula aquifer in the Laurel area. Under the moderate-growth scenario, water-level declines would be 40 feet or less below 1992 water levels in the middle Catahoula aquifer in the Hattiesburg area. Water-level declines would be about 110 feet in the lower Catahoula aquifer in the Laurel area, and water levels would approach the top of the aquifer. Under the high-growth scenario, water-level declines would be 40 feet or less in the upper Catahoula aquifer and about 80 feet in the middle Catahoula, with the largest declines occurring in the Hattiesburg area. Water levels would decline about 130 feet and would be drawn down below the top of the lower Catahoula aquifer in the Laurel area under the high-growth scenario.

  4. Revisitation of the dipole tracer test for heterogeneous porous formations

    NASA Astrophysics Data System (ADS)

    Zech, Alraune; D'Angelo, Claudia; Attinger, Sabine; Fiori, Aldo

    2018-05-01

    In this paper, a new analytical solution for interpreting dipole tests in heterogeneous media is derived by associating the shape of the tracer breakthrough curve with the log-conductivity variance. It is presented how the solution can be used for interpretation of dipole field test in view of geostatistical aquifer characterization on three illustrative examples. The analytical solution for the tracer breakthrough curve at the pumping well in a dipole tracer test is developed by considering a perfectly stratified formation. The analysis is carried out making use of the travel time of a generic solute particle, from the injection to the pumping well. Injection conditions are adapted to different possible field setting. Solutions are presented for resident and flux proportional injection mode as well as for an instantaneous pulse of solute and continuous solute injections. The analytical form of the solution allows a detailed investigation on the impact of heterogeneity, the tracer input conditions and ergodicity conditions at the well. The impact of heterogeneity manifests in a significant spreading of solute particles that increases the natural tendency to spreading induced by the dipole setup. Furthermore, with increasing heterogeneity the number of layers needed to reach ergodic conditions become larger. Thus, dipole test in highly heterogeneous aquifers might take place under non-ergodic conditions giving that the log-conductivity variance is underestimated. The method is a promising geostatistical analyzing tool being the first analytical solution for dipole tracer test analysis taking heterogeneity of hydraulic conductivity into account.

  5. Hydrogeology and Aquifer Storage and Recovery Performance in the Upper Floridan Aquifer, Southern Florida

    USGS Publications Warehouse

    Reese, Ronald S.; Alvarez-Zarikian, Carlos A.

    2007-01-01

    Well construction, hydraulic well test, ambient water-quality, and cycle test data were inventoried and compiled for 30 aquifer storage and recovery facilities constructed in the Floridan aquifer system in southern Florida. Most of the facilities are operated by local municipalities or counties in coastal areas, but five sites are currently being evaluated as part of the Comprehensive Everglades Restoration Plan. The relative performance of all sites with adequate cycle test data was determined, and compared with four hydrogeologic and design factors that may affect recovery efficiency. Testing or operational cycles include recharge, storage, and recovery periods that each last days or months. Cycle test data calculations were made including the potable water (chloride concentration of less than 250 milligrams per liter) recovery efficiency per cycle, total recovery efficiency per cycle, and cumulative potable water recovery efficiencies for all of the cycles at each site. The potable water recovery efficiency is the percentage of the total amount of potable water recharged for each cycle that is recovered; potable water recovery efficiency calculations (per cycle and cumulative) were the primary measures used to evaluate site performance in this study. Total recovery efficiency, which is the percent recovery at the end of each cycle, however, can be substantially higher and is the performance measure normally used in the operation of water-treatment plants. The Upper Floridan aquifer of the Floridan aquifer system currently is being used, or planned for use, at 29 of the aquifer storage and recovery sites. The Upper Floridan aquifer is continuous throughout southern Florida, and its overlying confinement is generally good; however, the aquifer contains brackish to saline ground water that can greatly affect freshwater storage and recovery due to dispersive mixing within the aquifer. The hydrogeology of the Upper Floridan varies in southern Florida; confinement between flow zones is better in southwestern Florida than in southeastern Florida. Vertical hydraulic conductivity in the upper part of the aquifer also may be higher in southeastern Florida because of unconformities present at formation contacts within the aquifer that may be better developed in this area. Recovery efficiencies per cycle varied widely. Eight sites had recovery efficiencies of less than about 10 percent for the first cycle, and three of these sites had not yet achieved recoveries exceeding 10 percent, even after three to five cycles. The highest recovery efficiency achieved per cycle was 94 percent. Three southeastern coastal sites and two southwestern coastal sites have achieved potable water recoveries per cycle exceeding 60 percent. One of the southeastern coastal sites and both of the southwestern coastal sites achieved good recoveries, even with long storage periods (from 174 to 191 days). The high recovery efficiencies for some cycles apparently resulted from water banking?an operational approach whereby an initial cycle with a large recharge volume of water is followed by cycles with much smaller recharge volume. This practice flushes out the aquifer around the well and builds up a buffer zone that can maintain high recovery efficiency in the subsequent cycles. The relative performance of all sites with adequate cycle test data was determined. Performance was arbitrarily grouped into ?high? (greater than 40 percent), ?medium? (between 20 and 40 percent), and ?low? (less than 20 percent) categories based primarily on their cumulative recovery efficiency for the first seven cycles, or projected to seven cycles if fewer cycles were conducted. The ratings of three sites, considered to be borderline, were modified using the overall recharge rate derived from the cumulative recharge volumes. A higher overall recharge rate (greater than 300 million gallons per year) can improve recovery efficiency because of the water-bankin

  6. Impact of climate change on mean groundwater residence time in several Mediterranean Spanish aquifers

    NASA Astrophysics Data System (ADS)

    Pulido-Velazquez, David; Marín-Lechado, Carlos; Martos-Rosillo, Sergio; Collados-Lara, Antonio-Juan; Ruíz-Constan, Ana

    2017-04-01

    The mean residence time in an aquifer, also known as natural turnover time or renewable period, can be obtained as the relation (R / St) between its storage capacity (St) and its recharge (R). It is an excellent indicator of the aquifer response capacity to its exploitation. Aquifers in which R is close to St values are extremely vulnerable to exploitation, even when it is less than the average recharge. This is especially relevant in Mediterranean climate areas, where long and intensive drought periods appear and will be exacerbated in future scenarios of global change. The natural turnover time depends on the recharge and the Global Change can produce important changes on it in the future. In this research we propose a method for a detailed estimation of natural turnover time by combining detailed 3D geological modelling of the case studies, estimated fields of specific yield for the aquifers (based on the analysis of multiple field sample), and rainfall-recharge models in several aquifer with different ratios of natural turnover time. These detailed 3D geological models have been defined by integrating information coming from seismic profiles, boreholes, magnetotelluric, electromagnetic and electrical sounding, digital elevation models, previous geological maps and new structural dates. They also allow us to deduce the reserve curve as a function of the elevation. On the other hand, different ensemble and downscaling techniques will be used to define potential future global climate change scenarios for the test-regions based on the data coming from simulations with different Regional Circulation Models (RCMs). These precipitation and temperature scenarios will be employed to feed the previously calibrated rainfall-recharge models in order to estimated future recharge and turnover time values. The methodology applied in this work could be a tool of special interest to identify at regional level which aquifers are most vulnerable to exploitation considering hydrogeological and climate change aspects. This research has been supported by the CGL2013-48424-C2-2-R (MINECO) Project.

  7. Recharge sources and geochemical evolution of groundwater in the Quaternary aquifer at Atfih area, the northeastern Nile Valley, Egypt

    NASA Astrophysics Data System (ADS)

    El-Sayed, Salah Abdelwahab; Morsy, Samah M.; Zakaria, Khalid M.

    2018-06-01

    This study addresses the topic of recharge sources and evolution of groundwater in the Atfih area situated in the northeastern part of the Nile Valley, Egypt. Inventory of water wells and collection of groundwater and surface water samples have been achieved. Water samples are analyzed for major ions according to the American Society for Testing and Materials and for the environmental isotopes analysis (oxygen-18 and deuterium) by using a Triple Liquid Isotopic Water Analyzer (Los Gatos). The groundwater is available from the Quaternary aquifer formed mainly of graded sand and gravel interbedded with clay lenses. The hydrogeologic, hydrogeochemical and isotopic investigations indicate the hydrodynamic nature of the aquifer, where different flow paths, recharge sources and evolution mechanisms are distinguished. The directions of groundwater flow are from E, W and S directions suggesting the contribution from Nile River, the Eocene aquifer and the Nile basin, respectively. The groundwater altitudes range from 13 m (MSL) to 44 m (MSL). The hydraulic gradient varies between 0.025 and 0.0015. The groundwater is alkaline (pH > 7) and has salinity ranging from fresh to brackish water (TDS between 528 mg/l and 6070 mg/l). The observed wide range in the ionic composition and water types reflects the effect of different environmental and geological conditions through which the water has flowed. The isotopic compositions of groundwater samples vary between -14.13‰ and +23.56 for δD and between - 2.91‰ and +3.10 for δ18O. The isotopic data indicates that the Quaternary aquifer receive recharge from different sources including the Recent Nile water, surplus irrigation water, old Nile water before the construction of Aswan High Dam, surface runoff of local rains and Eocene aquifer. Evaporation, water rock interaction and mixing between different types of waters are the main processes in the groundwater evolution. Major suggestions are presented to develop the aquifer productivity and to mitigate the deterioration of groundwater quality.

  8. Fractal analysis of the hydraulic conductivity on a sandy porous media reproduced in a laboratory facility.

    NASA Astrophysics Data System (ADS)

    de Bartolo, S.; Fallico, C.; Straface, S.; Troisi, S.; Veltri, M.

    2009-04-01

    The complexity characterization of the porous media structure, in terms of the "pore" phase and the "solid" phase, can be carried out by means of the fractal geometry which is able to put in relationship the soil structural properties and the water content. It is particularly complicated to describe analytically the hydraulic conductivity for the irregularity of the porous media structure. However these can be described by many fractal models considering the soil structure as the distribution of particles dimensions, the distribution of the solid aggregates, the surface of the pore-solid interface and the fractal mass of the "pore" and "solid" phases. In this paper the fractal model of Yu and Cheng (2002) and Yu and Liu (2004), for a saturated bidispersed porous media, was considered. This model, using the Sierpinsky-type gasket scheme, doesn't contain empiric constants and furnishes a well accord with the experimental data. For this study an unconfined aquifer was reproduced by means of a tank with a volume of 10 Ã- 7 Ã- 3 m3, filled with a homogeneous sand (95% of SiO2), with a high percentage (86.4%) of grains between 0.063mm and 0.125mm and a medium-high permeability. From the hydraulic point of view, 17 boreholes, a pumping well and a drainage ring around its edge were placed. The permeability was measured utilizing three different methods, consisting respectively in pumping test, slug test and laboratory analysis of an undisturbed soil cores, each of that involving in the measurement a different support volume. The temporal series of the drawdown obtained by the pumping test were analyzed by the Neuman-type Curve method (1972), because the saturated part above the bottom of the facility represents an unconfined aquifer. The data analysis of the slug test were performed by the Bouwer & Rice (1976) method and the laboratory analysis were performed on undisturbed saturated soil samples utilizing a falling head permeameter. The obtained values either of the fractal dimension of the area of the pores (Df) or of the fractal dimension of capillary tortuosity (DT), very similar to those reported in literature (Yu and Cheng, 2002; Yu and Liu, 2004; Yu, 2005) and falling in the range of definition (1 < Df < 2), resulted very close to those carried out in a previous study performed on the same apparatus but with a limited number of values (De Bartolo et al., in review). In fact in the present study the laboratory analysis were performed on other 10 undisturbed soil samples and moreover three new values of slug test and 12 new of pumping test were considered. Moreover the trend of DT growing with the scale length (L) was confirmed, as well as the invariability of, due to the homogeneity of the considered porous media. The linear scaling law of the permeability (k) close to scale length was investigated furnishing more reliable results. However for a better definition of a law of scale for Df, DT and k several number of scale length are need and a greater number of experimental data should be carried out. For this purpose the considered experimental apparatus is limited from its restricted dimensions and geometric bounds; therefore further investigations in experimental field are desirable. Bibliografy Bouwer, H. & Rice, R. C. 1976. A Slug Test for Hydraulic Conductivity of Unconfined Aquifers With Completely or Partially Penetrating Wells, Water Resources Research, 12(3). De Bartolo, S., Fallico, C., Straface, S., Troisi, S. & Veltri M. (in review). Scaling of the hydraulic conductivity measurements by a fractal analysis on an unconfined aquifer reproduced in a laboratory facility, Geoderma Special Issue 2008. Neuman, S.P. 1972. Theory of flow in unconfined aquifers considering delayed response of the water table, Water Resources Research, 8(4), 1031-1045. Yu, B.M. 2005. Fractal Character for Tortuous Streamtubes in Porous Media, Chin. Phis. Lett., 22(1), 158. Yu, B.M. & Cheng, P. 2002. A Fractal Permeability Model for Bi-Dispersed Porous Media, Int. J. Heat Mass Transfer 45(14), 2983. Yu, B.M. & Liu W. 2004. Fractal Analysis of Permeabilities for Porous Media, American Institute of Chemical Engineers 50(1), 46-57.

  9. Accounting for the Decreasing Reaction Potential of Heterogeneous Aquifers in a Stochastic Framework of Aquifer-Scale Reactive Transport

    NASA Astrophysics Data System (ADS)

    Loschko, Matthias; Wöhling, Thomas; Rudolph, David L.; Cirpka, Olaf A.

    2018-01-01

    Many groundwater contaminants react with components of the aquifer matrix, causing a depletion of the aquifer's reactivity with time. We discuss conceptual simplifications of reactive transport that allow the implementation of a decreasing reaction potential in reactive-transport simulations in chemically and hydraulically heterogeneous aquifers without relying on a fully explicit description. We replace spatial coordinates by travel-times and use the concept of relative reactivity, which represents the reaction-partner supply from the matrix relative to a reference. Microorganisms facilitating the reactions are not explicitly modeled. Solute mixing is neglected. Streamlines, obtained by particle tracking, are discretized in travel-time increments with variable content of reaction partners in the matrix. As exemplary reactive system, we consider aerobic respiration and denitrification with simplified reaction equations: Dissolved oxygen undergoes conditional zero-order decay, nitrate follows first-order decay, which is inhibited in the presence of dissolved oxygen. Both reactions deplete the bioavailable organic carbon of the matrix, which in turn determines the relative reactivity. These simplifications reduce the computational effort, facilitating stochastic simulations of reactive transport on the aquifer scale. In a one-dimensional test case with a more detailed description of the reactions, we derive a potential relationship between the bioavailable organic-carbon content and the relative reactivity. In a three-dimensional steady-state test case, we use the simplified model to calculate the decreasing denitrification potential of an artificial aquifer over 200 years in an ensemble of 200 members. We demonstrate that the uncertainty in predicting the nitrate breakthrough in a heterogeneous aquifer decreases with increasing scale of observation.

  10. Unconfined aquifer response to infiltration basins and shallow pump tests

    NASA Astrophysics Data System (ADS)

    Ostendorf, David W.; DeGroot, Don J.; Hinlein, Erich S.

    2007-05-01

    SummaryWe measure and model the unsteady, axisymmetric response of an unconfined aquifer to delayed, arbitrary recharge. Water table drainage follows the initial elastic aquifer response, as modeled for uniform, instantaneous recharge by Zlotnik and Ledder [Zlotnik, V., Ledder, G., 1992. Groundwater flow in a compressible unconfined aquifer with uniform circular recharge. Water Resources Research 28(6), 1619-1630] and delayed drainage by Moench [Moench, A.F., 1995. Combining the Neuman and Boulton models for flow to a well in an unconfined aquifer. Ground Water 33(3), 378-384]. We extend their analyses with a convolution integral that models the delayed response of an aquifer to infiltration from a circular infiltration basin. The basin routes the hydrograph to the water table with a decay constant dependent on a Brooks and Corey [Brooks, R.H., Corey, A.T., 1966. Properties of porous media affecting fluid flow. Journal of the Irrigation and Drainage Division ASCE 92(2), 61-88] unsaturated permeability exponent. The resulting closed form model approaches Neuman's [Neuman, S.P., 1972. Theory of flow in unconfined aquifers considering delayed response of the water table. Water Resources Research 8(4), 1031-1045] partially penetrating pump test equation for a small source radius, instantaneous, uniform drainage and a shallow screen section. Irrigation pump data at a well characterized part of the Plymouth-Carver Aquifer in southeastern Massachusetts calibrate the small source model, while infiltration data from the closed drainage system of State Route 25 calibrate the infiltration basin model. The calibrated permeability, elasticity, specific yield, and permeability exponent are plausible and consistent for the pump and infiltration data sets.

  11. Geohydrology of the Oklahoma Panhandle, Beaver, Cimarron, and Texas Counties

    USGS Publications Warehouse

    Hart, D.L.; Hoffman, G.L.; Goemaat, Robert L.

    1976-01-01

    The Ogallala aquifer, which consists of semiconsolidated clay, sand, and gravel, is the principal source of ground water in the Oklahoma Panhandle. This aquifer commonly yields 500 to 1,000 gallons per minute (32 to 63 litres per second) and may yield as much as 2,500 gallons per minute (158 litres per second). Based on an estimated average storage coefficient of 0.1, the quantity of water stored in the Ogallala aquifer was computed at approximately 50 million acre-feet (6.17 x 101° cubic metres). Local overdevelopment of this water resource has resulted in water-level declines of more than 40 feet (12 metres) from 1966 to 1972 in some areas of concentrated well development. The amount of ground water in storage has been reduced about 2 percent during this period.Aquifer tests indicate that transmissivity ranges from 500 to 11,800 feet squared per day (46 to 1,100 metres squared per day), the storage coefficient ranges from 0.002 to 0.11, and hydraulic conductivity ranges from 2.1 to 55 feet per day (0.6 to 16.8 metres per day). In addition to these tests, 802 specific-capacity tests were used to extend transmissivity data.Recharge to the Ogallala aquifer is primarily from precipitation and may be as much as 1 inch (25 millimetres) per year in areas where catchment and percolation are most favorable. Discharge is primarily from pumping and a small amount of natural discharge.Aquifers of limited importance are the Dakota Sandstone and the Cheyenne Sandstone Member of the Purgatoire Formation which provide water to irrigation wells in the southwestern part of Cimarron County. Irrigation wells generally are completed jointly in these aquifers and yields of 300 to 500 gallons per minute (19 to 32 litres per second) are common. Water levels in these aquifers have not shown the pronounced declines that have occurred in the Ogallala aquifer. Permian red beds provide only small quantities of water to domestic and stock wells.Water in the Ogallala aquifer, Dakota Sandstone, and Cheyenne Sandstone Member generally has a dissolved-solids concentration of less than 500 milligrams per litre. The dissolved-solids concentration in water from the Permian red beds generally exceeds 500 milligrams per litre and locally exceeds 2,000 milligrams per litre.

  12. Hydraulic properties of groundwater systems in the saprolite and sediments of the wheatbelt, Western Australia

    NASA Astrophysics Data System (ADS)

    George, Richard J.

    1992-01-01

    Hydraulic properties of deeply weathered basement rocks and variably weathered sedimentary materials were measured by pumping and slug-test methods. Results from over 200 bores in 13 catchments, and eight pumping-test sites across the eastern and central wheatbelt of Western Australia were analysed. Measurements were made in each of the major lithological units, and emphasis placed on a ubiquitous basal saprolite aquifer. Comparisons were made between alternative drilling and analytical procedures to determine the most appropriate methods of investigation. Aquifers with an average hydraulic conductivity of 0.55 m day -1 occur in variably weathered Cainozoic sediments and poorly weathered saprolite grits (0.57 m day -1). These aquifers are separated by an aquitard (0.065 m day -1) comprising the mottled and pallid zones of the deeply weathered profile. Locally higher values of hydraulic conductivity occur in the saprolite aquifer, although after prolonged periods of pumping the values decrease until they are similar to those obtained from the slug-test methods. Hydraulic conductivities measured in bores drilled with rotary auger rigs were approximately an order of magnitude lower than those measured in the same material with bores drilled by the rotary air-blast method. Wheatbelt aquifers range from predominantly unconfined (Cainozoic sediments), to confined (saprolite grit aquifer). The poorly weathered saprolite grit aquifer has moderate to high transmissivities (4-50 m 2 day -1) and is capable of producing from less than 5 to over 230 kl day -1 of ground water, which is often of a quality suitable for livestock. Yields are influenced by the variability in the permeability of isovolumetrically weathered materials from which the aquifer is derived. The overlying aquitard has a low transmissivity (< 1 m 2 day -1), especially when deeply weathered, indurated and silicified. The transmissivity of the variably weathered sedimentary materials ranges from less than 0.5 m 2 day -1 to over 10 m 2 day -1, depending on the texture of the materials and their position within the landscape. Higher transmissivity zones may occur as discrete layers of coarser textured materials. The salinity of the saprolite and sedimentary aquifers ranges from less than 2000 mgl -1 to greater than 250000 mgl -1 (total dissolved solids; TDS), depending on position within the landscape. Secondary soil salinization develops when groundwater discharge occurs from either saprolite or sedimentary aquifers.

  13. Tracer tests and the structure of permeability in the Corallian limestone aquifer of northern England, UK

    NASA Astrophysics Data System (ADS)

    Foley, Aidan; Cachandt, Gerd; Franklin, Janine; Willmore, Fergus; Atkinson, Tim

    2012-05-01

    The Corallian limestone of northern England (UK) is widely exploited for water supplies and exhibits the karstic phenomena of sinking rivers, conduit development and groundwater velocities of several kilometres per day. To test a number of model-derived source protection zones and elucidate contaminant transport mechanisms in the aquifer, three tracer tests were conducted from a set of swallow-holes draining the River Derwent toward public water supply wells in the eastern part of the aquifer. Tracers used included: Enterobacter cloacae (bacteriophage), Photine C (optical brightener), sodium fluorescein (fluorescent dye) and sulphur hexafluoride (dissolved gas), the varying properties of which make them suitable analogues for different types of potential contaminant. Observed tracer transport times and arrival patterns indicate that tracer transport occurs through karstic channels embedded in a network of primary fissures which exert control over tracer concentrations once initial tracer plumes have passed. A dipole flow system is observed between the swallow-holes and the closest abstraction well, whilst previously modelled source protection zones do not accurately reflect either groundwater velocity or those areas of the aquifer supplying the wells. These findings imply that managing such aquifers for potential contamination should rely upon empirical tracer evidence for source-protection zone modelling.

  14. Atoll island hydrogeology: flow and freshwater occurrence in a tidally dominated system

    NASA Astrophysics Data System (ADS)

    Oberdorfer, June A.; Hogan, Patrick J.; Buddemeier, Robert W.

    1990-12-01

    A layered-aquifer model of groundwater occurrence in an atoll island was tested with a solute-transport numerical model. The computer model used, SUTRA, incorporates density-dependent flow. This can be significant in freshwater-saltwater interactions associated with the freshwater lens of an atoll island. Boundary conditions for the model included ocean and lagoon tidal variations. The model was calibrated to field data from Enjebi Island, Enewetak Atoll, and tested for sensitivity to a variety of parameters. This resulted in a hydraulic conductivity of 10 m day -1 for the surficial aquifer and 1000 m day -1 for the deeper aquifer; this combination of values gave an excellent reproduction of the tidal response data from test wells. The average salinity distribution was closely reproduced using a dispersivity of 0.02m. The computer simulation quantitatively supports the layered-aquifer model, including under conditions of density-dependent flow, and shows that tidal variations are the predominant driving force for flow beneath the island. The oscillating, vertical flow produced by the tidal variations creates an extensive mixing zone of brackish water. The layered-aquifer model with tidally driven flow is a significant improvement over the Ghyben-Herzberg-Dupuit model as it is conventionally applied to groundwater studies for many Pacific reef islands.

  15. Use of tandem circulation wells to measure hydraulic conductivity without groundwater extraction

    NASA Astrophysics Data System (ADS)

    Goltz, Mark N.; Huang, Junqi; Close, Murray E.; Flintoft, Mark J.; Pang, Liping

    2008-09-01

    Conventional methods to measure the hydraulic conductivity of an aquifer on a relatively large scale (10-100 m) require extraction of significant quantities of groundwater. This can be expensive, and otherwise problematic, when investigating a contaminated aquifer. In this study, innovative approaches that make use of tandem circulation wells to measure hydraulic conductivity are proposed. These approaches measure conductivity on a relatively large scale, but do not require extraction of groundwater. Two basic approaches for using circulation wells to measure hydraulic conductivity are presented; one approach is based upon the dipole-flow test method, while the other approach relies on a tracer test to measure the flow of water between two recirculating wells. The approaches are tested in a relatively homogeneous and isotropic artificial aquifer, where the conductivities measured by both approaches are compared to each other and to the previously measured hydraulic conductivity of the aquifer. It was shown that both approaches have the potential to accurately measure horizontal and vertical hydraulic conductivity for a relatively large subsurface volume without the need to pump groundwater to the surface. Future work is recommended to evaluate the ability of these tandem circulation wells to accurately measure hydraulic conductivity when anisotropy and heterogeneity are greater than in the artificial aquifer used for these studies.

  16. Influence of the Redundant Verification and the Non-Redundant Verification on the Hydraulic Tomography

    NASA Astrophysics Data System (ADS)

    Wei, T. B.; Chen, Y. L.; Lin, H. R.; Huang, S. Y.; Yeh, T. C. J.; Wen, J. C.

    2016-12-01

    In the groundwater study, it estimated the heterogeneous spatial distribution of hydraulic Properties, there were many scholars use to hydraulic tomography (HT) from field site pumping tests to estimate inverse of heterogeneous spatial distribution of hydraulic Properties, to prove the most of most field site aquifer was heterogeneous hydrogeological parameters spatial distribution field. Many scholars had proposed a method of hydraulic tomography to estimate heterogeneous spatial distribution of hydraulic Properties of aquifer, the Huang et al. [2011] was used the non-redundant verification analysis of pumping wells changed, observation wells fixed on the inverse and the forward, to reflect the feasibility of the heterogeneous spatial distribution of hydraulic Properties of field site aquifer of the non-redundant verification analysis on steady-state model.From post literature, finding only in steady state, non-redundant verification analysis of pumping well changed location and observation wells fixed location for inverse and forward. But the studies had not yet pumping wells fixed or changed location, and observation wells fixed location for redundant verification or observation wells change location for non-redundant verification of the various combinations may to explore of influences of hydraulic tomography method. In this study, it carried out redundant verification method and non-redundant verification method for forward to influences of hydraulic tomography method in transient. And it discuss above mentioned in NYUST campus sites the actual case, to prove the effectiveness of hydraulic tomography methods, and confirmed the feasibility on inverse and forward analysis from analysis results.Keywords: Hydraulic Tomography, Redundant Verification, Heterogeneous, Inverse, Forward

  17. Direct Evidence of Meltwater Flow Within a Firn Aquifer in Southeast Greenland

    NASA Astrophysics Data System (ADS)

    Miller, Olivia; Solomon, D. Kip; Miège, Clément; Koenig, Lora; Forster, Richard; Schmerr, Nicholas; Ligtenberg, Stefan R. M.; Montgomery, Lynn

    2018-01-01

    Within the lower percolation zone of the southeastern Greenland ice sheet, meltwater has accumulated within the firn pore space, forming extensive firn aquifers. Previously, it was unclear if these aquifers stored or facilitated meltwater runoff. Following mixing of a saline solution into boreholes within the aquifer, we observe that specific conductance measurements decreased over time as flowing freshwater diluted the saline mixture in the borehole. These tests indicate that water flows through the aquifer with an average specific discharge of 4.3 × 10-6 m/s (σ = 2.5 × 10-6 m/s). The specific discharge decreases dramatically to 0 m/s, defining the bottom of the aquifer between 30 to 50 m depth. The observed flow indicates that the firn pore space is a short-term (<30 years) storage mechanism in this region. Meltwater flows out of the aquifer, likely into nearby crevasses, and possibly down to the base of the ice sheet and into the ocean.

  18. Effect of amphiphilic polyurethane nanoparticles on sorption-desorption of phenanthrene in aquifer material.

    PubMed

    Kim, Ju-Young; Shim, Sun-Bo; Shim, Jin-Kie

    2003-03-17

    Micelle-like amphiphilic nano-sized polyurethane (APU) nanoparticles were synthesized via chemical cross-linking reaction of nano-aggregates of urethane acrylate nonionomer (UAN) chain and were tested for extraction efficiency of sorbed phenanthrene from aquifer material. Even though the solubilizing performance and interfacial activity of APU nanoparticles were inferior to that of Triton X-100, in the low concentration region, APU nanoparticles could effectively reduce phenanthrene sorption on the aquifer material and extracted sorbed phenanthrene from the aquifer material, whereas Triton X-100 could not extract sorbed phenanthrene and rather increased phenanthrene sorption onto the aquifer materials. At higher concentrations, APU nanoparticles and Triton X-100 had almost the same soil washing effectiveness. This interesting result is mainly due to a lower degree of sorption of APU nanoparticles onto the aquifer material. The sorption of APU nanoparticles onto aquifer sand is largely hindered by their chemically cross-linked nature, resulting in better soil-washing performance of APU nanoparticles than Triton X-100. Copyright 2003 Elsevier Science B.V.

  19. Impact of Heterogeneity on Vadose Zone Drainage During Pumping: Numerical Simulations of the Borden Aquifer

    NASA Astrophysics Data System (ADS)

    Bunn, M. I.; Jones, J.; Endres, A. L.

    2009-05-01

    Unconfined aquifers are in direct contact with the earth's surface; hence, they are an important focus in groundwater recharge and contaminant transport studies. While pumping tests have long been used to quantify aquifer properties, the contribution of drainage from the vadose zone during pumping has been the subject of debate for decades. In 2001, a highly detailed data set was collected during a seven-day pumping test in the unconfined aquifer at CFB Borden, Ontario (Bevan et al., 2005). The frequent observation of moisture content profiles during the test has initiated a closer examination of the vadose zone response to pumping. The moisture profiles collected during the test were obtained using a neutron probe. The neutron data depicts a capillary fringe thickness that increases with both proximity to the pumping well and duration of pumping. This capillary fringe extension results in delayed drainage that persists to the end of the seven-day test with the shape of the transition zone remaining constant (Bevan et al., 2005). Simulations of the pumping test were conducted using Hydrogeosphere (Therrien et al., 2006). Initial simulations were completed based on the conceptual model of a homogeneous and slightly anisotropic aquifer. The simulation results replicated the observed piezometric response, but were unable to produce any change in the thickness of the capillary fringe. It was hypothesized that the discrepancy between observations and simulation results may be the result of assumptions such as the homogeneity of the hydraulic conductivity field. In an effort to replicate this potential mechanism for the observed extension, the conceptual model was updated to better reflect the mildly heterogeneous hydraulic conductivity field of the Borden aquifer. Conductivity fields were generated using the statistical description of the Borden aquifer given by Sudicky (1986) with an adjusted mean log conductivity to better approximate the observed piezometric response. The inclusion of heterogeneity appears to have little effect on the hydraulic head drawdown, or the thickness of the capillary fringe. Heterogeneity does lead to delayed drainage in the drier portion of the vadose zone, where volumetric water content is less than 0.13 m3/m3. This effect is more pronounced with proximity to the pumping well, and is negligible at 15 m from the well. The amount of excess moisture in the vadose zone does not appear to be a function of pumping duration.

  20. Review: Regional land subsidence accompanying groundwater extraction

    USGS Publications Warehouse

    Galloway, Devin L.; Burbey, Thomas J.

    2011-01-01

    The extraction of groundwater can generate land subsidence by causing the compaction of susceptible aquifer systems, typically unconsolidated alluvial or basin-fill aquifer systems comprising aquifers and aquitards. Various ground-based and remotely sensed methods are used to measure and map subsidence. Many areas of subsidence caused by groundwater pumping have been identified and monitored, and corrective measures to slow or halt subsidence have been devised. Two principal means are used to mitigate subsidence caused by groundwater withdrawal—reduction of groundwater withdrawal, and artificial recharge. Analysis and simulation of aquifer-system compaction follow from the basic relations between head, stress, compressibility, and groundwater flow and are addressed primarily using two approaches—one based on conventional groundwater flow theory and one based on linear poroelasticity theory. Research and development to improve the assessment and analysis of aquifer-system compaction, the accompanying subsidence and potential ground ruptures are needed in the topic areas of the hydromechanical behavior of aquitards, the role of horizontal deformation, the application of differential synthetic aperture radar interferometry, and the regional-scale simulation of coupled groundwater flow and aquifer-system deformation to support resource management and hazard mitigation measures.

  1. A method for evaluating horizontal well pumping tests.

    PubMed

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  2. Evidence for Upward Flow of Saline Water from Depth into the Mississippi River Valley Alluvial Aquifer in Southeastern Arkansas

    NASA Astrophysics Data System (ADS)

    Larsen, D.; Paul, J.

    2017-12-01

    Groundwater salinization is occurring in the Mississippi River Valley Alluvial (MRVA) aquifer in southeastern Arkansas (SE AR). Water samples from the MRVA aquifer in Chicot and Desha counties have yielded elevated Cl-concentrations with some as high as 1,639 mg/L. Considering that the MRVA aquifer is the principle source of irrigation water for the agricultural economy of SE AR, salinization needs to be addressed to ensure the sustainability of crop, groundwater, and soil resources in the area. The origin of elevated salinity in MRVA aquifer was investigated using spatial and factor analysis of historical water quality data, and sampling and tracer analysis of groundwater from irrigation, municipal, and flowing industrial wells in SE AR. Spatial analysis of Cl- data in relation to soil type, geomorphic features and sand-blow density indicate that the Cl- anomalies are more closely related to the sand-blow density than soil data, suggesting an underlying tectonic control for the distribution of salinity. Factor analysis of historical geochemical data from the MRVA and underlying Sparta aquifer shows dilute and saline groups, with saline groups weighted positively with Cl- or Na+ and Cl-. Tracer data suggest a component of evaporatively evolved crustal water of pre-modern age has mixed with younger, fresher meteoric sources in SE AR to create the saline conditions in the MRVA aquifer. Stable hydrogen and oxygen values of waters sampled from the Tertiary Sparta and MRVA aquifers deviate from the global and local meteoric water lines along an evaporative trend (slope=4.4) and mixing line with Eocene Wilcox Group groundwaters. Ca2+ and Cl- contents vary with Br- along mixing trends between dilute MRVA water and Jurassic Smackover Formation pore fluids in southern AR. Increasing Cl- content with C-14 age in MRVA aquifer groundwater suggests that the older waters are more saline. Helium isotope ratios decrease with He gas content for more saline water, consistent with crustal He production. Our model for the system invokes upward migration of Smackover pore fluids and other deep groundwater along faults in SE AR, whereby the saline fluids intrude and mix with dilute water in the MRVA aquifer to create saline conditions. Other processes, such as infiltration of saline irrigation runoff, may also be contributing to the problem.

  3. Estimation of hydraulic parameters from an unconfined aquifer test conducted in a glacial outwash deposit, Cape Cod, Massachusetts

    USGS Publications Warehouse

    Moench, Allen F.; Garabedian, Stephen P.; LeBlanc, Denis R.

    2001-01-01

    An aquifer test conducted in a sand and gravel, glacial outwash deposit on Cape Cod, Massachusetts was analyzed by means of a model for flow to a partially penetrating well in a homogeneous, anisotropic unconfined aquifer. The model is designed to account for all significant mechanisms expected to influence drawdown in observation piezometers and in the pumped well. In addition to the usual fluid-flow and storage processes, additional processes include effects of storage in the pumped well, storage in observation piezometers, effects of skin at the pumped-well screen, and effects of drainage from the zone above the water table.

  4. Multi-level slug tests in highly permeable formations: 2. Hydraulic conductivity identification, method verification, and field applications

    USGS Publications Warehouse

    Zlotnik, V.A.; McGuire, V.L.

    1998-01-01

    Using the developed theory and modified Springer-Gelhar (SG) model, an identification method is proposed for estimating hydraulic conductivity from multi-level slug tests. The computerized algorithm calculates hydraulic conductivity from both monotonic and oscillatory well responses obtained using a double-packer system. Field verification of the method was performed at a specially designed fully penetrating well of 0.1-m diameter with a 10-m screen in a sand and gravel alluvial aquifer (MSEA site, Shelton, Nebraska). During well installation, disturbed core samples were collected every 0.6 m using a split-spoon sampler. Vertical profiles of hydraulic conductivity were produced on the basis of grain-size analysis of the disturbed core samples. These results closely correlate with the vertical profile of horizontal hydraulic conductivity obtained by interpreting multi-level slug test responses using the modified SG model. The identification method was applied to interpret the response from 474 slug tests in 156 locations at the MSEA site. More than 60% of responses were oscillatory. The method produced a good match to experimental data for both oscillatory and monotonic responses using an automated curve matching procedure. The proposed method allowed us to drastically increase the efficiency of each well used for aquifer characterization and to process massive arrays of field data. Recommendations generalizing this experience to massive application of the proposed method are developed.Using the developed theory and modified Springer-Gelhar (SG) model, an identification method is proposed for estimating hydraulic conductivity from multi-level slug tests. The computerized algorithm calculates hydraulic conductivity from both monotonic and oscillatory well responses obtained using a double-packer system. Field verification of the method was performed at a specially designed fully penetrating well of 0.1-m diameter with a 10-m screen in a sand and gravel alluvial aquifer (MSEA site, Shelton, Nebraska). During well installation, disturbed core samples were collected every 0.6 m using a split-spoon sampler. Vertical profiles of hydraulic conductivity were produced on the basis of grain-size analysis of the disturbed core samples. These results closely correlate with the vertical profile of horizontal hydraulic conductivity obtained by interpreting multi-level slug test responses using the modified SG model. The identification method was applied to interpret the response from 474 slug tests in 156 locations at the MSEA site. More than 60% of responses were oscillatory. The method produced a good match to experimental data for both oscillatory and monotonic responses using an automated curve matching procedure. The proposed method allowed us to drastically increase the efficiency of each well used for aquifer characterization and to process massive arrays of field data. Recommendations generalizing this experience to massive application of the proposed method are developed.

  5. Geology of the surficial aquifer system, Dade County, Florida; lithologic logs

    USGS Publications Warehouse

    Causaras, C.R.

    1986-01-01

    The geologic framework of the surficial aquifer system in Dade County, Florida, was investigated as part of a longterm study by the USGS in cooperation with the South Florida Water Management District, to describe the geology, hydrologic characteristics, and groundwater quality of the surficial aquifer system. Thirty-three test wells were drilled completely through the surficial aquifer system and into the underlying, relatively impermeable units of the Tamiami and Hawthorn Formations. Detailed lithologic logs were made from microscopic examination of rock cuttings and cores obtained from these wells. The logs were used to prepare geologic sections that show the lithologic variations, thickness of the lithologic units, and different geologic formations that comprise the aquifers system. (Author 's abstract)

  6. Influence of tidal fluctuations in the water table and methods applied in the calculation of hydrogeological parameters. The case of Motril-Salobreña coastal aquifer

    NASA Astrophysics Data System (ADS)

    Sánchez Úbeda, Juan Pedro; Calvache Quesada, María Luisa; Duque Calvache, Carlos; López Chicano, Manuel; Martín Rosales, Wenceslao

    2013-04-01

    The hydraulic properties of coastal aquifer are essential for any estimation of groundwater flow with simple calculations or modelling techniques. Usually the application of slug test or tracers test are the techniques selected for solving the uncertainties. Other methods are based on the information associated to the changes induced by tidal fluctuation in coastal zones. The Tidal Response Method is a simple technique based in two different factors, tidal efficiency factor and time lag of the tidal oscillation regarding to hydraulic head oscillation caused into the aquifer. This method was described for a homogeneous and isotropic confined aquifer; however, it's applicable to unconfined aquifers when the ratio of maximum water table fluctuation and the saturated aquifer thickness is less than 0.02. Moreover, the tidal equations assume that the tidal signal follows a sinusoidal wave, but actually, the tidal wave is a set of simple harmonic components. Due to this, another methods based in the Fourier series have been applied in earlier studies trying to describe the tidal wave. Nevertheless, the Tidal Response Method represents an acceptable and useful technique in the Motril-Salobreña coastal aquifer. From recently hydraulic head data sets at discharge zone of the Motril-Salobreña aquifer have been calculated transmissivity values using different methods based in the tidal fluctuations and its effects on the hydraulic head. The effects of the tidal oscillation are detected in two boreholes of 132 m and 38 m depth located 300 m to the coastline. The main difficulties for the application of the method were the consideration of a confined aquifer and the variation of the effect at different depths (that is not included into the tidal equations), but these troubles were solved. In one hand, the assumption that the storage coefficient (S) in this unconfined aquifer is close to confined aquifers values due to the hydrogeological conditions at high depth and without saturation changes. In the other hand, we have monitored hydraulic head fluctuations due to tidal oscillations in different shallow boreholes close to the shoreline, and comparing with the deep ones. The calculated values with the tidal efficiency factor in the deep boreholes are about one less order of magnitude regarding to the obtained results with time lag method. Nevertheless, the application of these calculation methods based on tidal response in unconfined aquifers provides knowledge about the characteristics of the discharge zone and groundwater flow patterns, and it may be an easy and profitable alternative to traditional pumping tests.

  7. Artificial recharge to a freshwater-sensitive brackish-water sand aquifer, Norfolk, Virginia

    USGS Publications Warehouse

    Brown, Donald L.; Silvey, William Dudley

    1977-01-01

    Fresh water was injected into a brackish-water sand for storage and retrieval. The initial injection rate of 400 gpm decreased to 70 gpm during test 3. The specific capacity of the well decreased also, from 15.4 to 0.93 gpm. Current-meter surveys indicated uniform reduction in hydraulic conductivity of all contributing zones in the aquifer. Hydraulic and chemical data indicate this was caused by dispersion of the interstitial clay upon introduction of the calcium bicarbonate water into the sodium chloride bearing sand aquifer. The clay dispersion also caused particulate rearrangement and clogging of well screen. A pre-flush of 0.2 N calcium chloride solution injected in front of the fresh water at the start of test 4 stabilized the clay. However, it did not reverse the particulate clogging that permanently reduced permeability and caused sanding during redevelopment. Clogging can be prevented by stabilization of the clay using commercially available trivalent aluminum compounds. Test 1 and test 2 showed that 85 percent of the water injected can be recovered, and the water meets U.S. Public Health Standards. Storage of fresh water in a brackish-water aquifer appears feasible provided proper control measures are used. (Woodard-USGS)

  8. Geochemical studies of backfill aggregates, lake sediment cores and the Hueco Bolson Aquifer

    NASA Astrophysics Data System (ADS)

    Thapalia, Anita

    This dissertation comprises of three different researches that focuses on the application of geochemistry from aggregates, lake sediment cores and Hueco Bolson Aquifer. Each study is independent and presented in the publication format. The first chapter is already published and the second chapter is in revision phase. Overall, three studies measure the large scale (field) as well as bench scale (lab) water-rock interactions influenced by the climatic and anthropogenic factors spans from the field of environmental geology to civil engineering. The first chapter of this dissertation addresses the chemical evaluation of coarse aggregates from six different quarries in Texas. The goal of this work is to find out the best geochemical methods for assessing the corrosion potential of coarse aggregates prior to their use in mechanically stabilized earth walls. Electrochemical parameters help to define the corrosion potential of aggregates following two different leaching protocols. Testing the coarse and fine aggregates demonstrate the chemical difference due to size-related kinetic leaching effects. Field fines also show different chemistry than the bulk rock indicating the weathering impact on carbonate rocks. The second chapter investigates zinc (Zn) isotopic signatures from eight lake sediment cores collected both from pristine lakes and those impacted by urban anthropogenic contamination. Zinc from the natural weathering of rocks and anthropogenic atmospheric pollutants are transported to these lakes and the signatures are recorded in the sediments. Isotopic analysis of core samples provides the signature of anthropogenic contamination sources. Dated sediment core and isotopic analysis can identify Zn inputs that are correlated to the landuse and population change of the watersheds. Comparison of isotopic data from both pristine and urban lake sediment core also serves as an analog in other lake sediment cores in the world. The third chapter studies on Hueco Bolson Aquifer that an important sources of water in the El Paso/Cd. Juraez metroplex. To delineate the boundary between fresh and brackish water from the northern Hueco Bolson Aquifer, we utilize an integrative geochemical, geophysical, and sedimentological approach. The goal of this study is to use geophysical well-log analysis and the water chemical analysis for identifying the changes in the quality of the groundwater. A detailed microgravity survey is utilized to explore the subsurface geological structures that control the conduits and/or barriers of groundwater flow. A detailed geochemical analysis of aquifer samples provide salinity of groundwater that will complement to the subsurface structures obtained from the geophysical study. This fundamental research in developing methods from an integrated approach to estimate aquifer quality can be used as an analog for similar studies in other arid regions.

  9. Geohydrology and evaluation of water-resource potential of the upper Floridan Aquifer in the Albany area, southwestern Georgia

    USGS Publications Warehouse

    Torak, L.J.; Davis, G.S.; Strain, G.A.; Herndon, J.G.

    1993-01-01

    In the Albany area of southwestern Georgia, the Upper Floridan aquifer lies entirely within the Dougherty Plain district of the Coastal Plain physiographic province, and consists of the Ocala Limestone of late Eocene age. The aquifer is divided throughout most of the study area into an upper and a lower lithologic unit, which creates an upper and a lower water-bearing zone. The lower waterbearing zone consists of alternating layers of sandy limestone and medium-brown, recrystallized dolomitic limestone, and ranges in thickness from about 50 ft to 100 ft. It is highly fractured and exhibits well-developed permeability by solution features that are responsible for transmitting most of the ground water in the aquifer. Transmissivity of the lower water-bearing zone ranges from about 90,000 to 178,000 ft2/d. The upper water-bearing zone is a finely crystallized-to-oolitic, locally dolomitic limestone having an average thickness of about 60 ft. Transmissivities are considerably less in the upper water-bearing zone than in the lower water-bearing zone. The Upper Floridan aquifer is overlain by about 20-120 ft of undifferentiated overburden consisting of fine-to-coarse quartz sand and noncalcareous clay. A clay zone about 10-30 ft thick may be continuous throughout the southwestern part of the Albany area and, where present, causes confinement of the Upper Floridan aquifer and creates perched ground water after periods of heavy rainfall. The Upper Floridan aquifer is confined below by the Lisbon Formation, a mostly dolomitic limestone that contains trace amounts of glauconite. The Lisbon Formation is at least 50 ft thick in the study area and acts as an impermeable base to the Upper Floridan aquifer. The quality of ground water in the Upper Floridan aquifer is suitable for most uses; wells generally yield water of the hard, calcium-bicarbonate type that meets the U.S. Environmental Protection Agency's Primary or Secondary Drinking-Water Regulations. The water-resource potential of the Upper Floridan aquifer was evaluated by compiling results of drilling and aquifer testing in the study area, and by conducting computer simulations of the ground-water flow system under the seasonally low conditions of November 1985, and under conditions of pumping within a 12-mi 2 area located southwest of Albany. Results of test drilling, aquifer testing, and water-quality analyses indicate that, in the area southwest of Albany, geohydrologic conditions in the Upper Floridan aquifer, undifferentiated overburden, and Lisbon Formation were favorable for the aquifer to provide a large quantity of water without having adverse effects on the groundwater system. The confinement of the Upper Floridan aquifer by the undifferentiated overburden and the rural setting of the area of potential development decrease the likelihood that chemical constituents will enter the aquifer during development of the ground-water resources. Computer simulations of ground-water flow in the Upper Floridan aquifer, incorporating conditions for regional flow across model boundaries, leakage from rivers and other surface-water features, and vertical leakage from the undifferentiated overburden, were conducted by using a finite-element model for ground-water flow in two dimensions. Comparison of computed and measured water levels in the Upper Floridan aquifer for November 1985 at 74 locations indicated that computed water levels generally were within 5 ft of the measured values, which is the accuracy to which measured water levels were known. Water-level altitudes ranged from about 260 ft to 130 ft above sea level in the study area during calibration. Aquifer discharge to the Flint River downstream from the Lake Worth dam was computed by the calibrated model to be about 1 billion gallons per day; about 300 million gallons per day (Mgal/d) greater than was measured for similar lowflow conditions. The excess computed discharge was attributed partially to stream withdrawals for

  10. Efficient infiltration of water in the subsurface by using point-wells: A field study

    NASA Astrophysics Data System (ADS)

    Lopik, J. V.; Schotting, R.; Raoof, A.

    2017-12-01

    The ability to infiltrate large volumes of water in the subsurface would have great value for battling flooding in urban regions. Moreover, efficient water infiltration is key to optimize underground aquifer storage and recovery (ASR), aquifer thermal energy storage (ATES), as well as construction dewatering systems. Usually, variable infiltration rates of large water quantities could have a huge hydrogeological impact in the upper part of (phreatic) aquifer systems. In urban regions, minimizing excessive groundwater table fluctuations are necessary. A newly developed method, Fast, High Volume Infiltration (FHVI), by Dutch dewatering companies can be used to enable fast injection into the shallow subsurface. Conventional infiltration methods are using injection wells that screen large parts of the aquifer depth, whereas FHVI uses a specific infiltration point (1-m well screen) in the aquifer. These infiltration points are generally thin, high permeable layers in the aquifer of approximately 0.5-2 meter thick, and are embedded by less permeable layers. Currently, much higher infiltration pressures in shallow aquifers can be achieved with FHVI (up to 1 bar) compared to conventional infiltration methods ( 0.2 bar). Despite the high infiltration pressures and high discharge rate near the FHVI-filter, the stresses on shallow groundwater levels are significantly reduced with FHVI. In order to investigate the mechanisms that enable FHVI, a field experiment is conducted in a sandy aquifer to obtain insight in the 3-D hydraulic pressure distribution and flow patterns around a FHVI-filter during infiltration. A detailed characterization of the soil profile is obtained by using soil samples and cone pressure tests with a specific hydraulic profiling tool to track the vertical variation in aquifer permeability. A tracer test with bromide and heat is conducted to investigate preferential flow paths. The experimental data show that tracking small heterogeneities in aquifers and analysing the permeability difference ratio between the aimed infiltration layer and the surrounding layers in the aquifer are key to optimize the configuration of the FHVI-well. The results show that the use of point wells in thin, high permeable layers could drastically improve the efficiency of the infiltration system.

  11. A Novel Analytical Solution for Estimating Aquifer Properties and Predicting Stream Depletion Rates by Pumping from a Horizontally Anisotropic Aquifer

    NASA Astrophysics Data System (ADS)

    Huang, Y.; Zhan, H.; Knappett, P.

    2017-12-01

    Past studies modeling stream-aquifer interactions commonly account for vertical anisotropy, but rarely address horizontal anisotropy, which does exist in certain geological settings. Horizontal anisotropy is impacted by sediment deposition rates, orientation of sediment particles and orientations of fractures etc. We hypothesize that horizontal anisotropy controls the volume of recharge a pumped aquifer captures from the river. To test this hypothesis, a new mathematical model was developed to describe the distribution of drawdown from stream-bank pumping with a well screened across a horizontally anisotropic, confined aquifer, laterally bounded by a river. This new model was used to determine four aquifer parameters including the magnitude and directions of major and minor principal transmissivities and storativity based on the observed drawdown-time curves within a minimum of three non-collinear observation wells. By comparing the aquifer parameters values estimated from drawdown data generated known values, the discrepancies of the major and minor transmissivities, horizontal anisotropy ratio, storativity and the direction of major transmissivity were 13.1, 8.8, 4, 0 and <1 percent, respectively. These discrepancies are well within acceptable ranges of uncertainty for aquifer parameters estimation, when compared with other pumping test interpretation methods, which typically estimate uncertainty for the estimated parameters of 20 or 30 percent. Finally, the stream depletion rate was calculated as a function of stream-bank pumping. Unique to horizontally anisotropic aquifer, the stream depletion rate at any given pumping rate depends on the horizontal anisotropy ratio and the direction of the principle transmissivity. For example, when horizontal anisotropy ratios are 5 and 50 respectively, the corresponding depletion rate under pseudo steady-state condition are 86 m3/day and 91 m3/day. The results of this research fill a knowledge gap on predicting the response of horizontally anisotropic aquifers connected to streams. We further provide a method to estimate aquifer properties and predict stream depletion rates from observed drawdown. This new model can be used by water resources managers to exploit groundwater resource reasonably while protecting stream ecosystem.

  12. A closed form solution for constant flux pumping in a well under partial penetration condition

    NASA Astrophysics Data System (ADS)

    Yang, Shaw-Yang; Yeh, Hund-Der; Chiu, Pin-Yuan

    2006-05-01

    An analytical model for the constant flux pumping test is developed in a radial confined aquifer system with a partially penetrating well. The Laplace domain solution is derived by the application of the Laplace transforms with respect to time and the finite Fourier cosine transforms with respect to the vertical coordinates. A time domain solution is obtained using the inverse Laplace transforms, convolution theorem, and Bromwich integral method. The effect of partial penetration is apparent if the test well is completed with a short screen. An aquifer thickness 100 times larger than the screen length of the well can be considered as infinite. This solution can be used to investigate the effects of screen length and location on the drawdown distribution in a radial confined aquifer system and to produce type curves for the estimation of aquifer parameters with field pumping drawdown data.

  13. Geology of the surficial aquifer system, Broward County, Florida; lithologic logs

    USGS Publications Warehouse

    Causaras, C.R.

    1985-01-01

    The geologic framework of the surficial aquifer system, of which the Biscayne aquifer is the major component in Broward County, Florida, is presented in eight geologic cross sections. The cross sections are based on detailed lithologic logs of 27 test wells that were drilled, in the summer of 1981, through the sediments overlying the relatively impermeable units of the Hawthorn Formation, of Miocene age. The cross sections show the aquifer system as a wedge-shaped sequence of Cenozoic sediments. The aquifer thickness gradually decreases from more than 400 feet along the coast to about 160 feet in the west and southwest parts of Broward County. The sediments that comprise the aquifer system range in age from Pliocene to Pleistocene and are assigned to the following stratigraphic units from bottom to top: Tamiami Formation, Caloosahatchee Marl, Fort Thompson Formation, Key Largo Limestone, Anastasia Formation, Miami Oolite, and Pamlico Sand. (USGS)

  14. Aquifer response to stream-stage and recharge variations. II. Convolution method and applications

    NASA Astrophysics Data System (ADS)

    Barlow, P. M.; DeSimone, L. A.; Moench, A. F.

    2000-05-01

    In this second of two papers, analytical step-response functions, developed in the companion paper for several cases of transient hydraulic interaction between a fully penetrating stream and a confined, leaky, or water-table aquifer, are used in the convolution integral to calculate aquifer heads, streambank seepage rates, and bank storage that occur in response to stream-stage fluctuations and basinwide recharge or evapotranspiration. Two computer programs developed on the basis of these step-response functions and the convolution integral are applied to the analysis of hydraulic interaction of two alluvial stream-aquifer systems in the northeastern and central United States. These applications demonstrate the utility of the analytical functions and computer programs for estimating aquifer and streambank hydraulic properties, recharge rates, streambank seepage rates, and bank storage. Analysis of the water-table aquifer adjacent to the Blackstone River in Massachusetts suggests that the very shallow depth of water table and associated thin unsaturated zone at the site cause the aquifer to behave like a confined aquifer (negligible specific yield). This finding is consistent with previous studies that have shown that the effective specific yield of an unconfined aquifer approaches zero when the capillary fringe, where sediment pores are saturated by tension, extends to land surface. Under this condition, the aquifer's response is determined by elastic storage only. Estimates of horizontal and vertical hydraulic conductivity, specific yield, specific storage, and recharge for a water-table aquifer adjacent to the Cedar River in eastern Iowa, determined by the use of analytical methods, are in close agreement with those estimated by use of a more complex, multilayer numerical model of the aquifer. Streambank leakance of the semipervious streambank materials also was estimated for the site. The streambank-leakance parameter may be considered to be a general (or lumped) parameter that accounts not only for the resistance of flow at the river-aquifer boundary, but also for the effects of partial penetration of the river and other near-stream flow phenomena not included in the theoretical development of the step-response functions.

  15. Regional aquifer systems

    NASA Astrophysics Data System (ADS)

    The fifth in the American Water Resources Association (AWRA) Monograph series “Regional Aquifer Systems of the United States” has just been published as Monograph Series No. 13, “Aquifers of the Midwestern Area,” edited by L. A. Swain and A. Ivan Johnson. The 238-page publication is available for $18 to AWRA members and $21 for nonmembers.Each AWRA Annual Conference since 1985 has sponsored special seminars describing hydrologic, geochemical, and geologic characteristics of the Regional Aquifer System Analysis (RASA) studies carried out by the U.S. Geological Survey

  16. An analytical model for flow induced by a constant-head pumping in a leaky unconfined aquifer system with considering unsaturated flow

    NASA Astrophysics Data System (ADS)

    Lin, Ye-Chen; Li, Ming-Hsu; Yeh, Hund-Der

    2017-09-01

    A new mathematical model is developed to describe the flow in response to a constant-head pumping (or constant-head test, CHT) in a leaky unconfined aquifer system of infinite lateral extent with considering unsaturated flow. The model consists of an unsaturated zone on the top, an unconfined aquifer in the middle, and a second aquifer (aquitard) at the bottom. The unsaturated flow is described by Richard's equation, and the flows in unconfined aquifer and second layer are governed by the groundwater flow equation. The well partially penetrates the unconfined aquifer with a constant head in the well due to CHT. The governing equations of the model are linearized by the perturbation method and Gardner's exponential model is adopted to describe the soil retention curves. The solution of the model for drawdown distribution is obtained by applying the methods of Laplace transform and Weber transform. Then the solution for the wellbore flowrate is derived from the drawdown solution with Darcy's law. The issue of the equivalence of normalized drawdown predicted by the present solution for constant-head pumping and Tartakovsky and Neuman's (2007) solution for constant-rate pumping is discussed. On the basis of the wellbore flowrate solution, the results of the sensitivity analysis indicate that the wellbore flowrate is very sensitive to the changes in the radial hydraulic conductivity and the thickness of the saturated zone. Moreover, the results predicted from the present wellbore flowrate solution indicate that this new solution can reduce to Chang's et al. (2010a) solution for homogenous aquifers when the dimensionless unsaturated exponent approaches 100. The unsaturated zone can be considered as infinite extent in the vertical direction if the thickness ratio of the unsaturated zone to the unconfined aquifer is equal to or greater than one. As for the leakage effect, it can be ignored when the vertical hydraulic conductivity ratio (i.e., the vertical hydraulic conductivity of the lower layer over that of the unconfined aquifer) is smaller than 0.1. The present solution is compared with the numerical solution from FEMWATER for validation and the results indicate good match between these two solutions. Finally, the present solution is applied to a set of field drawdown data obtained from a CHT for the estimation of hydrogeologic parameters.

  17. Reconsideration at Field Scale of the Relationship between Hydraulic Conductivity and Porosity: The Case of a Sandy Aquifer in South Italy

    PubMed Central

    2014-01-01

    To describe flow or transport phenomena in porous media, relations between aquifer hydraulic conductivity and effective porosity can prove useful, avoiding the need to perform expensive and time consuming measurements. The practical applications generally require the determination of this parameter at field scale, while most of the empirical and semiempirical formulas, based on grain size analysis and allowing determination of the hydraulic conductivity from the porosity, are related to the laboratory scale and thus are not representative of the aquifer volumes to which one refers. Therefore, following the grain size distribution methodology, a new experimental relation between hydraulic conductivity and effective porosity, representative of aquifer volumes at field scale, is given for a confined aquifer. The experimental values used to determine this law were obtained for both parameters using only field measurements methods. The experimental results found, also if in the strict sense valid only for the investigated aquifer, can give useful suggestions for other alluvial aquifers with analogous characteristics of grain-size distribution. Limited to the investigated range, a useful comparison with the best known empirical formulas based on grain size analysis was carried out. The experimental data allowed also investigation of the existence of a scaling behaviour for both parameters considered. PMID:25180202

  18. Characteristics of streams and aquifers and processes affecting the salinity of water in the upper Colorado River basin, Texas

    USGS Publications Warehouse

    Slade, R.M.; Buszka, P.M.

    1994-01-01

    The chemical characteristics of the saline water in streams and shallow aquifers in the study area were compared to characteristics of water that would result from the probable processes affecting the salinity of water, such as evapotranspiration, mineral dissolution, and mixing of water from streams and shallow-aquifer water with brines from deep aquifers. Dissolution of halite or mixing with deep-aquifer water was the most common cause of increased salinity in 48.0 percent of 77 water samples from shallow aquifers, as classified using salt-norm analysis; the second most common cause was the weathering and dissolution of sulfur-bearing minerals. Mixing with water from soil-mineral dissolution was classified as the principal source of chloride in 28.4 percent of 67 water samples from shallow aquifers with nitrate determinations. Trace-species/chloride ratios indicated that mixing with water from deep aquifers in rocks of the Pennsylvanian System was the principal source of chloride in 24.4 percent of 45 shallow-aquifer samples lacking nitrate determinations.

  19. A quantitative comparison of moldic and vuggy porosity structure in karst aquifers using image and geospatial analysis

    NASA Astrophysics Data System (ADS)

    Culpepper, A. R.; Manda, A. K.

    2011-12-01

    Limestone aquifers are vital sources of groundwater for domestic and industrial use throughout the world. To sustain rising population throughout the southeastern United States, aquifers are increasingly exploited to provide the populace clean and reliable water resources. The moldic Castle Hayne and the vuggy Biscayne aquifer systems are two highly productive aquifers that provide critical water resources to millions of citizens in eastern North Carolina and southeastern Florida, respectively. In order to better understand karst aquifers and evaluate the potential for contaminant transport, detailed investigation of 2D porosity and pore geometry using image and geospatial analysis were undertaken. The objective of this study is to compare and contrast the porosity structure of moldic and vuggy karst aquifers by quantifying 2D porosity and pore geometry from images of slabbed core samples and optical televiewer images. Televiewer images and images of painted core samples from the Spring Garden Member of the Castle Hayne aquifer and Miami Limestone Formation of the Biscayne aquifer were acquired for analysis of porosity structure. The procedure for converting images of slabbed core and televiewer images to a GIS useable format consisted of rectification, calibration, image enhancement, classification, recoding and filtering. In GIS, raster or vector formats were used to assess pore attributes (e.g., area and perimeter) and structure. Preliminary results show that both pore area and perimeter for the Spring Garden Member of the Castle Hayne and Miami Limestone Formation of the Biscayne aquifers can be described by exponential distributions. In both sets of slabbed core images the relatively small pores have the highest occurrence, whereas larger pores occur less frequently. However, the moldic Spring Garden Member of the Castle Hayne aquifer has larger pore sizes derived from cores images than the vuggy Miami Limestone Formation of Biscayne aquifer. Total porosity derived from core images for the Spring Garden Member averages 37.5% whereas total porosity from the Miami Limestone Formation ranges between 10-48%. Analyses of televiewer images reveal the Miami Limestone Formation consists of conduits that range in aperture from a minimum of 0.86 cm to a maximum of 159 cm with an occurrence frequency of one conduit every two meters. Whereas, televiewer images of the Spring Garden Member of the Castle Aquifer do not reveal any conduits. This study presents an example of how quantitative measures of pore attributes and structure can be used to compare karst media with different porosity characteristics. Such measures will lead to a better understanding of porosity structure in karst aquifers that can be useful for designing and running ground water flow models and assessing transport mechanisms in karst media.

  20. Experimental study on the artificial recharge of semiconfined aquifers involved in deep excavation engineering

    NASA Astrophysics Data System (ADS)

    Zheng, G.; Cao, J. R.; Cheng, X. S.; Ha, D.; Wang, F. J.

    2018-02-01

    Artificial recharge measures have been adopted to control the drawdown of confined aquifers and the ground subsidence caused by dewatering during deep excavation in Tianjin, Shanghai and other regions in China. However, research on recharge theory is still limited. Additionally, confined aquifers consisting of silt and silty sand in Tianjin have lower hydraulic conductivities than those consisting of sand or gravel, and the feasibility and effectiveness of recharge methods in these semiconfined aquifers urgently require investigation. A series of single-well and multiwell pumping and recharge tests was conducted at a metro station excavation site in Tianjin. The test results showed that it was feasible to recharge silt and silty sand semiconfined aquifers, and, to a certain extent, the hydrogeological parameters obtained from the pumping tests could be used to predict the water level rise during single-well recharge. However, the predicted results underestimated the water level rise near the recharge well (within 7 m) by approximately 10-25%, likely because the permeability coefficient around the well was reduced during the recharge process. Pressured recharge significantly improved the efficiency of the recharge process. Maintaining the recharge and pumping rates at a nearly equal level effectively controlled the surrounding surface and building settlement. However, the surrounding surface subsidence tended to rapidly develop when recharge stopped. Therefore, the recharge process should continue and gradually stop after the pumping stops. The twin-well combined recharge technique can be used to control the head loss of an aquifer when one of the recharge wells requires pumping to solve the associated clogging problems.

  1. Hydrologic analysis of the U.S. Bureau of Mines' underground oil-shale research-facility site, Piceance Creek Basin, Rio Blanco County, Colorado

    USGS Publications Warehouse

    Dale, R.H.; Weeks, John B.

    1978-01-01

    The U.S. Bureau of Mines plans to develop an underground oil-shale research facility near the center of Piceance Creek basin in Colorado. The oil-shale zone, which is to be penetrated by a shaft, is overlain by 1,400 feet of sedimentary rocks, primarily sandstone and marlstone, consisting of two aquifers separated by a confining layer. Three test holes were drilled by the U.S. Bureau of Mines to obtain samples of the oil shale, and to test the hydraulic properties of the two aquifers. The data collected during construction of the test holes were used to update an existing ground-water-flow computer model. The model was used to estimate the maximum amount of water that would have to be pumped to dewater the shaft during its construction. It is estimated that it would be necessary to pump as much as 3,080 gallons per minute to keep the shaft dry. Disposal of waste water and rock are the principal hydrologic problems associated with constructing the shaft. (Woodard-USGS)

  2. The calculation of aquifer chemistry in hot-water geothermal systems

    USGS Publications Warehouse

    Truesdell, Alfred H.; Singers, Wendy

    1974-01-01

    The temperature and chemical conditions (pH, gas pressure, and ion activities) in a geothermal aquifer supplying a producing bore can be calculated from the enthalpy of the total fluid (liquid + vapor) produced and chemical analyses of water and steam separated and collected at known pressures. Alternatively, if a single water phase exists in the aquifer, the complete analysis (including gases) of a sample collected from the aquifer by a downhole sampler is sufficient to determine the aquifer chemistry without a measured value of the enthalpy. The assumptions made are that the fluid is produced from a single aquifer and is homogeneous in enthalpy and chemical composition. These calculations of aquifer chemistry involving large amounts of ancillary information and many iterations require computer methods. A computer program in PL-1 to perform these calculations is available from the National Technical Information Service as document PB-219 376.

  3. Low temperature-pressure batch experiments and field push-pull tests: Assessing potential effects of an unintended CO2 release from CCUS projects on groundwater chemistry

    NASA Astrophysics Data System (ADS)

    Mickler, P. J.; Yang, C.; Lu, J.; Reedy, R. C.; Scanlon, B. R.

    2012-12-01

    Carbon Capture Utilization and Storage projects (CCUS), where CO2 is captured at point sources such as power stations and compressed into a supercritical liquid for underground storage, has been proposed to reduce atmospheric CO2 and mitigate global climate change. Problems may arise from CO2 releases along discreet pathways such as abandoned wells and faults, upwards and into near surface groundwater. Migrating CO2 may inversely impact fresh water resources by increasing mineral solubility and dissolution rates and mobilizing harmful trace elements including As and Pb. This study addresses the impacts on fresh water resources through a combination of laboratory batch experiments, where aquifer sediment are reacted in their corresponding groundwater in 100% CO2 environments, and field push-pull tests where groundwater is equilibrated with 100% CO2, reacted in-situ in the groundwater system, and pulled out for analyses. Batch experiments were performed on aquifer material from carbonate dominated, mixed carbonate/silicalstic, and siliclastic dominated systems. A mixed silicalstic/carbonate system was chosen for the field based push-pull test. Batch experiment results suggest carbonate dissolution increased the concentration of Ca, Mg, Sr, Ba, Mn, U and HCO3- in groundwater. In systems with significant carbonate content, dissolution continued until carbonate saturation was achieved at approximately 1000 hr. Silicate dissolution increased the conc. of Si, K Ni and Co, but at much lower rates than carbonate dissolution. The elements As, Mo, V, Zn, Se and Cd generally show similar behavior where concentrations initially increase but soon drop to levels at or below the background concentrations (~48 hours). A Push-Pull test on one aquifer system produced similar geochemical behavior but observed reaction rates are higher in batch experiments relative to push-pull tests. Release of CO2 from CCUS sites into overlying aquifer systems may adversely impact groundwater quality primarily through carbonate dissolution which releases Ca and elements that substitute for Ca in crystal lattices. Silicate weathering releases primarily Si and K at lower rates. Chemical changes with the addition of CO2 may initially mobilize As, Mo, V, Zn, Se and Cd but these elements become immobile in the lowered pH water and sorb onto aquifer minerals. A combined laboratory batch experiment and field push-pull test in fresh water aquifers overlying CCUS projects will best characterize the response of the aquifer to increased pCO2. The long experimental duration of the batch experiments may allow reactions to reach equilibrium however; reaction rates may be artificially high due to increased mineral surface areas. Field based push-pull tests offer a more realistic water rock ratio and test a much larger volume of aquifer material but the test must be shorter in duration because the high pCO2 water is subject to mixing with low pCO2 background water and migration away from the test well with groundwater flow. A comparison of the two methods best characterizes the potential effects on groundwater chemistry

  4. Potentiometric surface of the Upper Floridan aquifer in Florida and parts of Georgia, South Carolina, and Alabama, May – June 2010

    USGS Publications Warehouse

    Kinnaman, Sandra L.; Dixon, Joann F.

    2011-01-01

    The Floridan aquifer system covers nearly 100,000 square miles in the southeastern United States throughout Florida and in parts of Georgia, South Carolina, and Alabama, and is one of the most productive aquifers in the world (Miller, 1990). This sequence of carbonate rocks is hydraulically connected and is over 300 feet thick in south Florida and thins toward the north. Typically, this sequence is subdivided into the Upper Floridan aquifer, the middle confining unit, and the Lower Floridan aquifer. The majority of freshwater is contained in the Upper Floridan aquifer and is used for water supply (Miller, 1986). The Lower Floridan aquifer contains fresh to brackish water in northeastern Florida and Georgia, while in south Florida it is saline. The potentiometric surface of the Upper Floridan aquifer in May–June 2010 shown on this map was constructed as part of the U.S. Geological Survey Floridan Aquifer System Groundwater Availability Study (U.S. Geological Survey database, 2011). Previous synoptic measurements and regional potentiometric maps of the Upper Floridan aquifer were prepared for May 1980 (Johnston and others, 1981) and May 1985 (Bush and others, 1986) as part of the Floridan Regional Aquifer System Analysis.

  5. Aquifer-test compilation for the San Joaquin Valley, California

    USGS Publications Warehouse

    McClelland, E.J.

    1962-01-01

    This report is the first of a series the purpose of which is to make available in standard tabular form the results of aquifer tests that have been made by various private and public agencies in California. The scope of the compilation is to describe systematically, in a form agreed upon by the California Department of Water Resources and the Geological Survey, the (1) test location, (2) pumping data, (3) well data, and (4) summary of results. The results of these tests sometimes have been published but most frequently have been used only as a step in obtaining other information, consequently the results and even the location of aquifer tests have not been readily available.This report has been prepared by the Geological Survey under the immediate supervision of Fred Kunkel, district geologist for California, in cooperation with the California Department of Water Resources, and tabulates through October 1962 all tests analyzed by the Geological Survey for the San Joaquin Valley. The report is designed to be expanded when additional tests are analyzed or new tests are made.

  6. Using noble gas tracers to estimate residual CO2 saturation in the field: results from the CO2CRC Otway residual saturation and dissolution test

    NASA Astrophysics Data System (ADS)

    LaForce, T.; Ennis-King, J.; Paterson, L.

    2013-12-01

    Residual CO2 saturation is a critically important parameter in CO2 storage as it can have a large impact on the available secure storage volume and post-injection CO2 migration. A suite of single-well tests to measure residual trapping was conducted at the Otway test site in Victoria, Australia during 2011. One or more of these tests could be conducted at a prospective CO2 storage site before large-scale injection. The test involved injection of 150 tonnes of pure carbon dioxide followed by 454 tonnes of CO2-saturated formation water to drive the carbon dioxide to residual saturation. This work presents a brief overview of the full test sequence, followed by the analysis and interpretation of the tests using noble gas tracers. Prior to CO2 injection krypton (Kr) and xenon (Xe) tracers were injected and back-produced to characterise the aquifer under single-phase conditions. After CO2 had been driven to residual the two tracers were injected and produced again. The noble gases act as non-partitioning aqueous-phase tracers in the undisturbed aquifer and as partitioning tracers in the presence of residual CO2. To estimate residual saturation from the tracer test data a one-dimensional radial model of the near-well region is used. In the model there are only two independent parameters: the apparent dispersivity of each tracer and the residual CO2 saturation. Independent analysis of the Kr and Xe tracer production curves gives the same estimate of residual saturation to within the accuracy of the method. Furthermore the residual from the noble gas tracer tests is consistent with other measurements in the sequence of tests.

  7. Using Boreholes as Windows into Groundwater Ecosystems

    PubMed Central

    Sorensen, James P. R.; Maurice, Louise; Edwards, François K.; Lapworth, Daniel J.; Read, Daniel S.; Allen, Debbie; Butcher, Andrew S.; Newbold, Lindsay K.; Townsend, Barry R.; Williams, Peter J.

    2013-01-01

    Groundwater ecosystems remain poorly understood yet may provide ecosystem services, make a unique contribution to biodiversity and contain useful bio-indicators of water quality. Little is known about ecosystem variability, the distribution of invertebrates within aquifers, or how representative boreholes are of aquifers. We addressed these issues using borehole imaging and single borehole dilution tests to identify three potential aquifer habitats (fractures, fissures or conduits) intercepted by two Chalk boreholes at different depths beneath the surface (34 to 98 m). These habitats were characterised by sampling the invertebrates, microbiology and hydrochemistry using a packer system to isolate them. Samples were taken with progressively increasing pumped volume to assess differences between borehole and aquifer communities. The study provides a new conceptual framework to infer the origin of water, invertebrates and microbes sampled from boreholes. It demonstrates that pumping 5 m3 at 0.4–1.8 l/sec was sufficient to entrain invertebrates from five to tens of metres into the aquifer during these packer tests. Invertebrates and bacteria were more abundant in the boreholes than in the aquifer, with associated water chemistry variations indicating that boreholes act as sites of enhanced biogeochemical cycling. There was some variability in invertebrate abundance and bacterial community structure between habitats, indicating ecological heterogeneity within the aquifer. However, invertebrates were captured in all aquifer samples, and bacterial abundance, major ion chemistry and dissolved oxygen remained similar. Therefore the study demonstrates that in the Chalk, ecosystems comprising bacteria and invertebrates extend from around the water table to 70 m below it. Hydrogeological techniques provide excellent scope for tackling outstanding questions in groundwater ecology, provided an appropriate conceptual hydrogeological understanding is applied. PMID:23936176

  8. Ground-water quality assessment of the central Oklahoma Aquifer, Oklahoma; project description

    USGS Publications Warehouse

    Christenson, S.C.; Parkhurst, D.L.

    1987-01-01

    In April 1986, the U.S. Geological Survey began a pilot program to assess the quality of the Nation's surface-water and ground-water resources. The program, known as the National Water-Quality Assessment (NAWQA) program, is designed to acquire and interpret information about a variety of water-quality issues. The Central Oklahoma aquifer project is one of three ground-water pilot projects that have been started. The NAWQA program also incudes four surface-water pilot projects. The Central Oklahoma aquifer project, as part of the pilot NAWQA program, will develop and test methods for performing assessments of ground-water quality. The objectives of the Central Oklahoma aquifer assessment are: (1) To investigate regional ground-water quality throughout the aquifer in the manner consistent with the other pilot ground-water projects, emphasizing the occurrence and distribution of potentially toxic substances in ground water, including trace elements, organic compounds, and radioactive constituents; (2) to describe relations between ground-water quality, land use, hydrogeology, and other pertinent factors; and (3) to provide a general description of the location, nature, and possible causes of selected prevalent water-quality problems within the study unit; and (4) to describe the potential for water-quality degradation of ground-water zones within the study unit. The Central Oklahoma aquifer, which includes in descending order the Garber Sandstone and Wellington Formation, the Chase Group, the Council Grove Group, the Admire Group, and overlying alluvium and terrace deposits, underlies about 3,000 square miles of central Oklahoma and is used extensively for municipal, industrial, commercial, and domestic water supplies. The aquifer was selected for study by the NAWQA program because it is a major source for water supplies in central Oklahoma and because it has several known or suspected water-quality problems. Known problems include concentrations of arsenic, chromium, selenium, and gross-alpha activity that exceed drinking-water standards. Suspected problems include possible contamination of the aquifer by oil-field brines and drilling fluids, pesticides, industrial chemicals, septic-tank effluent, fertilizers, and leakage from sewage systems and underground tanks used for storage of hydrocarbons. There are four major components of the Central Oklahoma aquifer project. The first component is the collection and analysis of existing information, including chemical, hydrologic, and land-use data. The second component is the geohydrologic and geochemical investigations of the aquifer flow system. The third component is the sampling for a wide variety of inorganic, organic, and radioactive constituents as part a regional survey that will produce a consistent set of data among all ground-water pilot projects. These data can be used to: (1) Define regional ground-water quality within the Central Oklahoma aquifer, and (2) compare water quality in the Central Oklahoma aquifer to the water quality in the other ground-water study units of the NAWQA program. The fourth component is topical studies that will address, in more detail, some of the major water-quality issues pertaining to the aquifer.

  9. Evaluation of processes affecting 1,2-dibromo-3-chloropropane (DBCP) concentrations in ground water in the eastern San Joaquin Valley, California : analysis of chemical data and ground-water flow and transport simulations

    USGS Publications Warehouse

    Burow, Karen R.; Panshin, Sandra Y.; Dubrovsky, Neil H.; Vanbrocklin, David; Fogg, Graham E.

    1999-01-01

    A conceptual two-dimensional numerical flow and transport modeling approach was used to test hypotheses addressing dispersion, transformation rate, and in a relative sense, the effects of ground- water pumping and reapplication of irrigation water on DBCP concentrations in the aquifer. The flow and transport simulations, which represent hypothetical steady-state flow conditions in the aquifer, were used to refine the conceptual understanding of the aquifer system rather than to predict future concentrations of DBCP. Results indicate that dispersion reduces peak concentrations, but this process alone does not account for the apparent decrease in DBCP concentrations in ground water in the eastern San Joaquin Valley. Ground-water pumping and reapplication of irrigation water may affect DBCP concentrations to the extent that this process can be simulated indirectly using first-order decay. Transport simulation results indicate that the in situ 'effective' half-life of DBCP caused by processes other than dispersion and transformation to BAA could be on the order of 6 years.

  10. A method to investigate inter-aquifer leakage using hydraulics and multiple environmental tracers

    NASA Astrophysics Data System (ADS)

    Priestley, Stacey; Love, Andrew; Wohling, Daniel; Post, Vincent; Shand, Paul; Kipfer, Rolf; Tyroller, Lina

    2016-04-01

    Informed aquifer management decisions regarding sustainable yields or potential exploitation require an understanding of the groundwater system (Alley et al. 2002, Cherry and Parker 2004). Recently, the increase in coal seam gas (CSG) or shale gas production has highlighted the need for a better understanding of inter-aquifer leakage and contaminant migration. In most groundwater systems, the quantity or location of inter-aquifer leakage is unknown. Not taking into account leakage rates in the analysis of large scale flow systems can also lead to significant errors in the estimates of groundwater flow rates in aquifers (Love et al. 1993, Toth 2009). There is an urgent need for robust methods to investigate inter-aquifer leakage at a regional scale. This study builds on previous groundwater flow and inter-aquifer leakage studies to provide a methodology to investigate inter-aquifer leakage in a regional sedimentary basin using hydraulics and a multi-tracer approach. The methodology incorporates geological, hydrogeological and hydrochemical information in the basin to determine the likelihood and location of inter-aquifer leakage. Of particular benefit is the analysis of hydraulic heads and environmental tracers at nested piezometers, or where these are unavailable bore couplets comprising bores above and below the aquitard of interest within a localised geographical area. The proposed methodology has been successful in investigating inter-aquifer leakage in the Arckaringa Basin, South Australia. The suite of environmental tracers and isotopes used to analyse inter-aquifer leakage included the stable isotopes of water, radiocarbon, chloride-36, 87Sr/86Sr and helium isotopes. There is evidence for inter-aquifer leakage in the centre of the basin ~40 km along the regional flow path. This inter-aquifer leakage has been identified by a slight draw-down in the upper aquifer during pumping in the lower aquifer, overlap in Sr isotopes, δ2H, δ18O and chloride concentrations as well as hydrochemical evidence of mixing with shallower groundwater with shorter residence times. References Alley W. M. Healy R. W. Labaugh J. W. Reilly T. E. 2002. Hydrology - Flow and storage in groundwater systems. Science 296: 1985-1990. Cherry J. A. Parker, B. L. 2004. Role of Aquitards in the Protection of Aquifers from Contamination: A "State of Science" Report. Denver, USA. AWWA Research Foundation. Love A. J. Herczeg A. L. Armstrong D. Stadter F. Mazor E. 1993. Groundwater-Flow Regime within the Gambier Embayment of the Otway Basin, Australia - Evidence from Hydraulics and Hydrochemistry. Journal of Hydrology 143: 297-338. Tóth J. 2009. Gravitational Systems of Groundwater Flow: Theory, Evaluation, Utilization. Cambridge University Press.

  11. SUBSURFACE RESIDENCE TIMES AS AN ALGORITHM FOR AQUIFER SENSITIVITY MAPPING: TESTING THE CONCEPT WITH GROUND WATER MODELS IN THE CONTENTNEA CREEK BASIN, NORTH CAROLINA, USA

    EPA Science Inventory

    This poster will present a modeling and mapping assessment of landscape sensitivity to non-point source pollution as applied to a hierarchy of catchment drainages in the Coastal Plain of the state of North Carolina. Analysis of the subsurface residence time of water in shallow a...

  12. Hydrogeologic Appraisal of the Valley-Fill Aquifer in the Port Jervis Trough, Sullivan and Ulster Counties, New York

    USGS Publications Warehouse

    Reynolds, Richard J.

    2007-01-01

    The nature and extent of valley-fill aquifers in the Port Jervis Trough was evaluated for a 16 mile section of this valley from the Orange-Sullivan County line near Westbrookville to the village of Napanoch in Ulster County as part of the U.S. Geological Survey's Detailed Aquifer Mapping Program in New York State. The principal aquifer in the Port Jervis Trough is a 50 feet thick outwash aquifer that extends from the Phillipsport Moraine near Summitville, southward through the study area to Port Jervis, N.Y. Previous studies had estimated as much as 500 feet of saturated drift in parts of the Trough, but new well data show that much of the valley fill consists of fine-grained lacustrine sediments. Drillers' logs show that the outwash aquifer south of Summitville is underlain by as much as 275 feet of lacustrine silt and clay. North of the Phillipsport Moraine, three large glaciolacustrine deltas that were built into Glacial Lake Wawarsing provide some local and discontinuous confined aquifers through their coarser bottomset beds. Elsewhere in the Trough, collapsed and buried portions of kame deltas and terraces provide local confined aquifers. The outwash aquifer appears to be very transmissive, as evidenced by the high specific capacity of 130 gallons per minute per foot [(gal/min)/ft] of a commercial test well screened in the aquifer.

  13. Are single-well "push-pull" tests suitable tracer methods for aquifer characterization?

    NASA Astrophysics Data System (ADS)

    Hebig, Klaus; Zeilfelder, Sarah; Ito, Narimitsu; Machida, Isao; Scheytt, Traugott; Marui, Atsunao

    2013-04-01

    Recently, investigations were conducted for geological and hydrogeological characterisation of the sedimentary coastal basin of Horonobe (Hokkaido, Japan). Coastal areas are typical geological settings in Japan, which are less tectonically active than the mountain ranges. In Asia, and especially in Japan, these areas are often densely populated. Therefore, it is important to investigate the behaviour of solutes in such unconsolidated aquifers. In such settings sometimes only single boreholes or groundwater monitoring wells are available for aquifer testing for various reasons, e.g. depths of more than 100 m below ground level and slow groundwater velocities due to density driven flow. A standard tracer test with several involved groundwater monitoring wells is generally very difficult or even not possible at these depths. One of the most important questions in our project was how we can obtain information about chemical and hydraulic properties in such aquifers. Is it possible to characterize solute transport behaviour parameters with only one available groundwater monitoring well or borehole? A so-called "push-pull" test may be one suitable method for aquifer testing with only one available access point. In a push-pull test a known amount of several solutes including a conservative tracer is injected into the aquifer ("push") and afterwards extracted ("pull"). The measured breakthrough curve during the pumping back phase can then be analysed. This method has already been used previously with various aims, also in the recent project (e.g. Hebig et al. 2011, Zeilfelder et al. 2012). However, different test setups produced different tracer breakthrough curves. As no systematic evaluation of this aquifer tracer test method was done so far, nothing is known about its repeatability. Does the injection and extraction rate influence the shape of the breakthrough curve? Which role plays the often applied "chaser", which is used to push the test solution out from the borehole and gravel pack? How does density difference between the original groundwater and the test solution influence the tracer breakthrough curves? To solve these questions, seven push-pull tests were performed under controlled boundary conditions in the same well DD-2 (100 m depth). Only single parameters, as e.g. flow rate or salinization of the test solution, were varied during the experiments. By conducting these different test setups, conclusions could be drawn about the application of the push-pull method under different settings. References: Hebig, K.H., Ito, N., Scheytt, T.J. & Marui, A. (2011). Hydraulic and hydrochemical characterization of deep coastal sedimentary basins by single-well Push-Pull tests. GSA Annual Meeting, 9-12 October 2011, Minneapolis, USA. Zeilfelder, S., Ito, N., Marui, A., Hebig, K. & Scheytt, T. (2012). Push-Pull-Test und Tracer-Test in ei-nem tiefen Grundwasserleiter in Kameoka, Japan. Kurzfassung in: Liedl, R., Burghardt, D., Simon, E., Reimann, T. & Kaufmann-Knoke (Hg.). Grundwasserschutz und Grundwassernutzung. Tagung der Fachsektion Hydrogeologie in der DGG (FH-DGG). 16. - 20. Mai 2012, Dresden. Kurfassungen der Vorträge und Poster. Schriftenreihe der DGG, Heft 78, S. 192.

  14. Geochemical processes during managed aquifer recharge with desalinated seawater

    NASA Astrophysics Data System (ADS)

    Ganot, Y.; Holtzman, R.; Weisbrod, N.; Russak, A.; Katz, Y.; Kurtzman, D.

    2017-12-01

    In this work we study the geochemical processes along the variably-saturated zone during managed aquifer recharge (MAR) with reverse-osmosis desalinated seawater (DSW) to an infiltration pond at the Menashe site, located above the Israeli coastal aquifer. The DSW is post-treated by calcite dissolution (remineralization) in order to meet the Israeli desalinated water quality criteria. Suction cups and monitoring wells inside the pond were used to monitor water quality during two MAR events on 2015 and 2016. Results show that cation exchange is dominant, driven by the high Ca2+ concentration in the post-treated DSW. Stable isotope analysis shows that the composition of the shallow groundwater is similar to the recharged DSW, but with enrichment of Mg2+, Na+, Ca2+ and HCO3-. A calibrated variably-saturated reactive transport model was used to predict the geochemical evolution during 50 years of MAR with two water quality scenarios: post-treated DSW and soft DSW (without post-treatment). The latter scenario was aimed to test soil-aquifer-treatment as an alternative post-treatment technique. In terms of water quality, the results of the two scenarios were found within the range of the desalinated water criteria. Mg2+ enrichment was stable ( 2.5 mg L-1), higher than the zero concentration found in the Israeli DSW. Calcite content reduction was low (<1%) along the variably-saturated profile, after 50 years of MAR. This suggests that using soil-aquifer-treatment as a remineralization technique for DSW is potentially a sustainable practice, which is limited only by the current hydraulic capacity of the Menashe MAR site.

  15. Geochemical Processes During Managed Aquifer Recharge With Desalinated Seawater

    NASA Astrophysics Data System (ADS)

    Ganot, Y.; Holtzman, R.; Weisbrod, N.; Russak, A.; Katz, Y.; Kurtzman, D.

    2018-02-01

    We study geochemical processes along the variably-saturated zone during managed aquifer recharge (MAR) with reverse-osmosis desalinated seawater (DSW). The DSW, post-treated at the desalination plant by calcite dissolution (remineralization) to meet the Israeli water quality standards, is recharged into the Israeli Coastal Aquifer through an infiltration pond. Water quality monitoring during two MAR events using suction cups and wells inside the pond indicates that cation exchange is the dominant subsurface reaction, driven by the high Ca2+ concentration in the post-treated DSW. Stable isotope analysis shows that the shallow groundwater composition is similar to the recharged DSW, except for enrichment of Mg2+, Na+, Ca2+, and HCO3-. A calibrated variably-saturated reactive transport model is used to predict the geochemical evolution during 50 years of MAR for two water quality scenarios: (i) post-treated DSW (current practice) and (ii) soft DSW (lacking the remineralization post-treatment process). The latter scenario was aimed to test soil-aquifer-treatment (SAT) as an alternative post-treatment technique. Both scenarios provide an enrichment of ˜2.5 mg L-1 in Mg2+ due to cation exchange, compared to practically zero Mg2+ currently found in the Israeli DSW. Simulations of the alternative SAT scenario provide Ca2+ and HCO3- remineralization due to calcite dissolution at levels that meet the Israeli standard for DSW. The simulated calcite content reduction in the sediments below the infiltration pond after 50 years of MAR was low (<1%). Our findings suggest that remineralization using SAT for DSW is a potentially sustainable practice at MAR sites overlying calcareous sandy aquifers.

  16. Effect of volcanic dykes on coastal groundwater flow and saltwater intrusion: A field-scale multiphysics approach and parameter evaluation

    NASA Astrophysics Data System (ADS)

    Comte, J.-C.; Wilson, C.; Ofterdinger, U.; González-Quirós, A.

    2017-03-01

    Volcanic dykes are common discrete heterogeneities in aquifers; however, there is a lack of field examples of, and methodologies for, comprehensive in situ characterization of their properties with respect to groundwater flow and solute transport. We have applied an integrated multiphysics approach to quantify the effect of dolerite dykes on saltwater intrusion in a coastal sandstone aquifer. The approach involved ground geophysical imaging (passive magnetics and electrical resistivity tomography), well hydraulic testing, and tidal propagation analysis, which provided constraints on the geometry of the dyke network, the subsurface saltwater distribution, and the sandstone hydrodynamic properties and connectivity. A three-dimensional variable-density groundwater model coupled with a resistivity model was further calibrated using groundwater and geophysical observations. A good agreement of model simulations with tide-induced head fluctuations, geophysically derived pore water salinities, and measured apparent resistivities was obtained when dykes' hydraulic conductivity, storativity, and effective porosity are respectively about 3, 1, and 1 orders of magnitude lower than the host aquifer. The presence of the dykes results in barrier-like alterations of groundwater flow and saltwater intrusion. Preferential flow paths occur parallel to observed dyke orientations. Freshwater inflows from upland recharge areas concentrate on the land-facing side of the dykes and saltwater penetration is higher on their sea-facing side. This has major implications for managing groundwater resources in dyke-intruded aquifers, including in coastal and island regions and provides wider insights on preferential pathways of groundwater flow and transport in highly heterogeneous aquifer systems.

  17. Lattice Boltzmann methods applied to large-scale three-dimensional virtual cores constructed from digital optical borehole images of the karst carbonate Biscayne aquifer in southeastern Florida

    USGS Publications Warehouse

    Michael Sukop,; Cunningham, Kevin J.

    2014-01-01

    Digital optical borehole images at approximately 2 mm vertical resolution and borehole caliper data were used to create three-dimensional renderings of the distribution of (1) matrix porosity and (2) vuggy megaporosity for the karst carbonate Biscayne aquifer in southeastern Florida. The renderings based on the borehole data were used as input into Lattice Boltzmann methods to obtain intrinsic permeability estimates for this extremely transmissive aquifer, where traditional aquifer test methods may fail due to very small drawdowns and non-Darcian flow that can reduce apparent hydraulic conductivity. Variogram analysis of the borehole data suggests a nearly isotropic rock structure at lag lengths up to the nominal borehole diameter. A strong correlation between the diameter of the borehole and the presence of vuggy megaporosity in the data set led to a bias in the variogram where the computed horizontal spatial autocorrelation is strong at lag distances greater than the nominal borehole size. Lattice Boltzmann simulation of flow across a 0.4 × 0.4 × 17 m (2.72 m3 volume) parallel-walled column of rendered matrix and vuggy megaporosity indicates a high hydraulic conductivity of 53 m s−1. This value is similar to previous Lattice Boltzmann calculations of hydraulic conductivity in smaller limestone samples of the Biscayne aquifer. The development of simulation methods that reproduce dual-porosity systems with higher resolution and fidelity and that consider flow through horizontally longer renderings could provide improved estimates of the hydraulic conductivity and help to address questions about the importance of scale.

  18. Lattice Boltzmann methods applied to large-scale three-dimensional virtual cores constructed from digital optical borehole images of the karst carbonate Biscayne aquifer in southeastern Florida

    NASA Astrophysics Data System (ADS)

    Sukop, Michael C.; Cunningham, Kevin J.

    2014-11-01

    Digital optical borehole images at approximately 2 mm vertical resolution and borehole caliper data were used to create three-dimensional renderings of the distribution of (1) matrix porosity and (2) vuggy megaporosity for the karst carbonate Biscayne aquifer in southeastern Florida. The renderings based on the borehole data were used as input into Lattice Boltzmann methods to obtain intrinsic permeability estimates for this extremely transmissive aquifer, where traditional aquifer test methods may fail due to very small drawdowns and non-Darcian flow that can reduce apparent hydraulic conductivity. Variogram analysis of the borehole data suggests a nearly isotropic rock structure at lag lengths up to the nominal borehole diameter. A strong correlation between the diameter of the borehole and the presence of vuggy megaporosity in the data set led to a bias in the variogram where the computed horizontal spatial autocorrelation is strong at lag distances greater than the nominal borehole size. Lattice Boltzmann simulation of flow across a 0.4 × 0.4 × 17 m (2.72 m3 volume) parallel-walled column of rendered matrix and vuggy megaporosity indicates a high hydraulic conductivity of 53 m s-1. This value is similar to previous Lattice Boltzmann calculations of hydraulic conductivity in smaller limestone samples of the Biscayne aquifer. The development of simulation methods that reproduce dual-porosity systems with higher resolution and fidelity and that consider flow through horizontally longer renderings could provide improved estimates of the hydraulic conductivity and help to address questions about the importance of scale.

  19. Substantial contribution of biomethylation to aquifer arsenic cycling

    USGS Publications Warehouse

    Maguffin, Scott C.; Kirk, Matthew F.; Daigle, Ashley R.; Hinkle, Stephen R.; Jin, Qusheng

    2015-01-01

    Microbes play a prominent role in transforming arsenic to and from immobile forms in aquifers1. Much of this cycling involves inorganic forms of arsenic2, but microbes can also generate organic forms through methylation3, although this process is often considered insignificant in aquifers4, 5, 6, 7. Here we identify the presence of dimethylarsinate and other methylated arsenic species in an aquifer hosted in volcaniclastic sedimentary rocks. We find that dimethylarsinate is widespread in the aquifer and its concentration correlates strongly with arsenite concentration. We use laboratory incubation experiments and an aquifer injection test to show that aquifer microbes can produce dimethylarsinate at rates of about 0.1% of total dissolved arsenic per day, comparable to rates of dimethylarsinate production in surface environments. Based on these results, we estimate that globally, biomethylation in aquifers has the potential to transform 100 tons of inorganic arsenic to methylated arsenic species per year, compared with the 420–1,250 tons of inorganic arsenic that undergoes biomethylation in soils8. We therefore conclude that biomethylation could contribute significantly to aquifer arsenic cycling. Because biomethylation yields arsine and methylarsines, which are more volatile and prone to diffusion than other arsenic species, we further suggest that biomethylation may serve as a link between surface and subsurface arsenic cycling.

  20. MULTISPECIES REACTIVE TRACER TEST IN A SAND AND GRAVEL AQUIFER, CAPE COD, MASSACHUSETTS: PART 1: EXPERIMENTAL DESIGN AND TRANSPORT OF BROMIDE AND NICKEL-EDTA TRACERS

    EPA Science Inventory

    In this report, we summarize a portion of the results of a large-scale tracer test conducted at the U. S. Geological Survey research site on Cape Cod, Massachusetts. The site is located on a large sand and gravel glacial outwash plain in an unconfined aquifer. In April 1993, ab...

  1. Hydrogeologic framework and simulation of ground-water flow and travel time in the shallow aquifer system in the area of Naval Support Activity Memphis, Millington, Tennessee

    USGS Publications Warehouse

    Robinson, James L.; Carmichael, John K.; Halford, Keith J.; Ladd, David E.

    1997-01-01

    Naval Support Activity (NSA) Memphis is a Department of the Navy facility located at the City of Millington, Tennessee, about 5 miles north of Memphis. Contaminants have been detected in surface-water, sediment, and ground-water samples collected at the facility. As part of the Installation Restoration Program, the Navy is considering remedial-action options to prevent or lessen the effect of ground-water contamination at the facility and to control the movement and discharge of contaminants. A numerical model of the ground-water-flow system in the area of NSA Memphis was constructed and calibrated so that quantifiable estimates could be made of ground-water-flow rates, direction, and time-of-travel. The sediments beneath NSA Memphis, to a depth of about 200 feet, form a shallow aquifer system. From youngest to oldest, the stratigraphic units that form the shallow aquifer system are alluvium, loess, fluvial deposits, and the Cockfield and Cook Mountain Formations. The shallow aquifer system is organized into five hydrogeologic units: (1) a confining unit composed of the relatively low permeability sediments of the upper alluvium and the loess; (2) the A1 aquifer comprising sand and gravel of the lower alluvium and the fluvial deposits, and sand lenses in the upper part of the preserved section of the Cockfield Formation; (3) a confining unit composed of clay and silt within the upper part of the Cockfield Formation; (4) the Cockfield aquifer comprising sand lenses within the lower part of the preserved section of the Cockfield Formation; and (5) a confining unit formed by low permeability sediments of the Cook Mountain Formation that composes the upper confining unit for the Memphis aquifer. Thicknesses of individual units vary considerably across the facility. Structural and depositional features that affect the occurrence of ground water in the shallow aquifer system include faulting, an erosional scarp, and 'windows' in the confining units. Underlying the shallow aquifer system is the Memphis aquifer, the primary source of water for NSA Memphis and the City of Memphis, Tennessee. Analyses of sediment cores, aquifer and well specific-capacity tests, and numerical modeling were used to estimate the hydraulic characteristics of units of the shallow aquifer system. The vertical hydraulic conductivity of core samples of the alluvium-loess confining unit ranged from about 8.5 x 10-5 to 1.6 x 10-2 feet per day, and the total porosity of the samples ranged from about 35 to 48 percent. The results of the aquifer test were used to estimate a horizontal hydraulic conductivity of about 5 feet per day for the alluvial-fluvial deposits aquifer. The total porosity of core samples of the alluvial-fluvial deposits aquifer ranged from about 22 to 39 percent. The vertical hydraulic conductivity of core samples of the Cockfield confining unit ranged from about 4.5 x 10-5 to 2.5 x 10-3 feet per day, and the total porosity ranged from about 41 to 55 percent. Well specific-capacity tests indicate that the horizontal hydraulic conductivity of sand units that compose the Cockfield aquifer range from about 0.5 to 3 feet per day. The vertical hydraulic conductivity of core samples of the Cook Mountain confining unit ranged from about 5.0 x 10-6 to 9.9 x 10-4 feet per day. Total porosity of core samples of the Cook Mountain confining unit ranged from about 30 to 42 percent. Ground-water flow and time-of-travel in the shallow aquifer system were simulated using the MODFLOW finite-difference model and the -particle-tracking program MODPATH. A three-layer, steady-state model of the shallow aquifer system was constructed and calibrated to the potentiometric surface of the A1 aquifer. Results of numerical modeling support the proposed conceptual hydrogeologic model of the shallow aquifer system. Ground-water time-of-travel in the A1 aquifer was simulated using an assumed effective porosity of 25 percent. Typical ground-water-flow velocities were on the or

  2. Applicability of aquifer impact models to support decisions at CO 2 sequestration sites

    DOE PAGES

    Keating, Elizabeth; Bacon, Diana; Carroll, Susan; ...

    2016-07-25

    The National Risk Assessment Partnership has developed a suite of tools to assess and manage risk at CO 2 sequestration sites. This capability includes polynomial or look-up table based reduced-order models (ROMs) that predict the impact of CO 2 and brine leaks on overlying aquifers. The development of these computationally-efficient models and the underlying reactive transport simulations they emulate has been documented elsewhere (Carroll et al., 2014a; Carroll et al., 2014b; Dai et al., 2014 ; Keating et al., 2016). Here in this paper, we seek to demonstrate applicability of ROM-based analysis by considering what types of decisions and aquifermore » types would benefit from the ROM analysis. We present four hypothetical examples where applying ROMs, in ensemble mode, could support decisions during a geologic CO 2 sequestration project. These decisions pertain to site selection, site characterization, monitoring network evaluation, and health impacts. In all cases, we consider potential brine/CO 2 leak rates at the base of the aquifer to be uncertain. We show that derived probabilities provide information relevant to the decision at hand. Although the ROMs were developed using site-specific data from two aquifers (High Plains and Edwards), the models accept aquifer characteristics as variable inputs and so they may have more broad applicability. We conclude that pH and TDS predictions are the most transferable to other aquifers based on the analysis of the nine water quality metrics (pH, TDS, 4 trace metals, 3 organic compounds). Guidelines are presented for determining the aquifer types for which the ROMs should be applicable.« less

  3. Spatial and temporal changes in microbial community structure associated with recharge-influenced chemical gradients in a contaminated aquifer

    USGS Publications Warehouse

    Haack, S.K.; Fogarty, L.R.; West, T.G.; Alm, E.W.; McGuire, J.T.; Long, D.T.; Hyndman, D.W.; Forney, L.J.

    2004-01-01

    In a contaminated water-table aquifer, we related microbial community structure on aquifer sediments to gradients in 24 geochemical and contaminant variables at five depths, under three recharge conditions. Community amplified ribsosomal DNA restriction analysis (ARDRA) using universal 16S rDNA primers and denaturing gradient gel electrophoresis (DGGE) using bacterial 16S rDNA primers indicated: (i) communities in the anoxic, contaminated central zone were similar regardless of recharge; (ii) after recharge, communities at greatest depth were similar to those in uncontaminated zones; and (iii) after extended lack of recharge, communities at upper and lower aquifer margins differed from communities at the same depths on other dates. General aquifer geochemistry was as important as contaminant or terminal electron accepting process (TEAP) chemistry in discriminant analysis of community groups. The Shannon index of diversity (H) and the evenness index (E), based on DGGE operational taxonomic units (OTUs), were statistically different across community groups and aquifer depths. Archaea or sulphate-reducing bacteria 16S rRNA abundance was not clearly correlated with TEAP chemistry indicative of methanogenesis or sulphate reduction. Eukarya rRNA abundance varied by depth and date from 0 to 13% of the microbial community. This contaminated aquifer is a dynamic ecosystem, with complex interactions between physical, chemical and biotic components, which should be considered in the interpretation of aquifer geochemistry and in the development of conceptual or predictive models for natural attenuation or remediation.

  4. Comment on "Horizontal aquifer movement in a theis-theim confined system, by Donald C. Helm

    USGS Publications Warehouse

    Hsieh, Paul A.; Cooley, Richard L.

    1995-01-01

    In a recent paper, Helm [1994] presents an analysis of horizontal aquifer movement induced by groundwater withdrawal from a confined aquifer in which fluid and grains are incompressible. The analysis considers the aquifer in isolation (ignoring overlying and underlying strata) and assumes that the aquifer deforms purely in the horizontal direction (with no vertical movement). Helm's solution for grain displacement is obtained through introduction of a quantity known as bulk flux, qb, defined asqb = nvw + (1 - n)vswhere n is porosity, vw is velocity of water, and vs is the velocity of the solid grains. On the basis of the bulk flux concept, Helm develops an explanation for the driving force on the bulk material.It is our view that Helm's analysis is subject to four limitations. First, Helm's assumption of zero vertical displacement is not supported by field observations and could result in over- estimation of radial displacement. Second, in ignoring the role of overlying and underlying strata, Helm's solution does not yield reliable estimates of aquifer deformation. Third, Helm's solution method works only for problems that involve one spatial coordinate (for example, x or r) but does not generally work for problems involving three-dimensional flow and de- formation. Fourth, Helm's explanation of the driving force on the bulk material is faulty for general three-dimensional problems. The purpose of our comment is to discuss these four issues.

  5. A nonlinear model for analysis of slug-test data

    USGS Publications Warehouse

    McElwee, C.D.; Zenner, M.A.

    1998-01-01

    While doing slug tests in high-permeability aquifers, we have consistently seen deviations from the expected response of linear theoretical models. Normalized curves do not coincide for various initial heads, as would be predicted by linear theories, and are shifted to larger times for higher initial heads. We have developed a general nonlinear model based on the Navier-Stokes equation, nonlinear frictional loss, non-Darcian flow, acceleration effects, radius changes in the well bore, and a Hvorslev model for the aquifer, which explains these data features. The model produces a very good fit for both oscillatory and nonoscillatory field data, using a single set of physical parameters to predict the field data for various initial displacements at a given well. This is in contrast to linear models which have a systematic lack of fit and indicate that hydraulic conductivity varies with the initial displacement. We recommend multiple slug tests with a considerable variation in initial head displacement to evaluate the possible presence of nonlinear effects. Our conclusion is that the nonlinear model presented here is an excellent tool to analyze slug tests, covering the range from the underdamped region to the overdamped region.

  6. Interpretation of geophysical logs, aquifer tests, and water levels in wells in and near the North Penn Area 7 Superfund site, Upper Gwynedd Township, Montgomery County, Pennsylvania, 2000-02

    USGS Publications Warehouse

    Senior, Lisa A.; Cinotto, Peter J.; Conger, Randall W.; Bird, Philip H.; Pracht, Karl A.

    2005-01-01

    Ground water in the vicinity of various industrial facilities in Upper Gwynedd Township and Lansdale Borough, Montgomery County, Pa., is contaminated with various volatile organic compounds (VOCs). The 2-square-mile area was placed on the National Priorities List as the North Penn Area 7 Superfund site by the U.S. Environmental Protection Agency (USEPA) in 1989. The U.S. Geological Survey (USGS) conducted geophysical logging, aquifer testing, water-level monitoring, and streamflow measurements in the vicinity of North Penn Area 7 beginning autumn 2000 to assist the USEPA in developing an understanding of the hydrogeologic framework in the area as part of the USEPA Remedial Investigation. The study area is underlain by Triassic and Jurassic-age sandstones, siltstones, and shales of the Lockatong Formation and the Brunswick Group. Regionally, these rocks strike northeast and dip to the northwest. The sequence of rocks form a fractured-sedimentary-rock aquifer that acts as a set of confined to partially confined layered aquifers of differing permeabilities. The aquifers are recharged by precipitation and discharge to streams and wells. The Wissahickon Creek headwaters are less than 1 mile northeast of the study area, and this stream flows southwest to bisect North Penn Area 7. Ground water is pumped in the vicinity of North Penn Area 7 for industrial use and public supply. The USGS collected geophysical logs for 16 wells that ranged in depth from 50 to 623 feet. Aquifer-interval-isolation testing was done in 9 of the 16 wells, for a total of 30 zones tested. A multiple-well aquifer test was conducted by monitoring the response of 14 wells to pumping a 600-ft deep production well in February and March 2002. In addition, water levels were monitored continuously in three wells in the area and streamflow was measured quarterly at two sites on Wissahickon Creek from December 2000 through September 2002. Geophysical logging identified water-bearing zones associated with high-angle fractures and bedding-plane openings throughout the depth of the boreholes. Heatpulse-flowmeter measurements under nonpumping, ambient conditions indicated that borehole flow, where detected, was in the upward direction in three of the eight wells and in the downward direction in three wells. In two wells, both upward and downward flow were measured. Heatpulse-flowmeter measurements under pumping conditions were used to identify the most productive intervals in wells. Correlation of natural-gamma-ray and single-point-resistance logs indicated that bedding in the area probably strikes about 40 degrees northeast and dips from 6 to 7 degrees northwest. Aquifer intervals isolated by inflatable packers in wells were pumped to test productivity and to collect samples to determine chemical quality of water produced from the interval. Interval-isolation testing confirmed the presence of vertical hydraulic gradients indicated by heatpulse-flowmeter measurements. The specific capacities of isolated intervals ranged over two orders of magnitude, from 0.02 to more than 3.6 gallons per minute per foot. Intervals adjacent to isolated pumped intervals showed little response to pumping the isolated zone. The presence of vertical hydraulic gradients and lack of adjacent-interval response to pumping in isolated intervals indicate a limited degree of vertical hydraulic connection between the aquifer intervals tested. Concentrations of most VOC contaminants generally were highest in well-water samples from the shallowest isolated intervals, with some exceptions. Trichloroethylene, cis-1,2-dichloroethylene, and toluene were the most frequently detected VOCs, with maximum concentrations of greater than 340, 680, and greater than 590 micrograms per liter, respectively. Results of the aquifer test with multiple observation wells showed that water levels in 4 of the 14 wells declined in response to pumping. The four wells that responded to pumping are either along str

  7. Interactions of diffuse and focused allogenic recharge in an eogenetic karst aquifer (Florida, USA)

    NASA Astrophysics Data System (ADS)

    Langston, Abigail L.; Screaton, Elizabeth J.; Martin, Jonathan B.; Bailly-Comte, Vincent

    2012-06-01

    The karstic upper Floridan aquifer in north-central Florida (USA) is recharged by both diffuse and allogenic recharge. To understand how recharged water moves within the aquifer, water levels and specific conductivities were monitored and slug tests were conducted in wells installed in the aquifer surrounding the Santa Fe River Sink and Rise. Results indicate that diffuse recharge does not mix rapidly within the aquifer but instead flows horizontally. Stratification may be aided by the high matrix porosity of the eogenetic karst aquifer. Purging wells for sample collection perturbed conductivity for several days, reflecting mixing of the stratified water and rendering collection of representative samples difficult. Interpretive numerical simulations suggest that diffuse recharge impacts the intrusion of allogenic water from the conduit by increasing hydraulic head in the surrounding aquifer and thereby reducing influx to the aquifer from the conduit. In turn, the increase of head within the conduits affects flow paths of diffuse recharge by moving newly recharged water vertically as the water table rises and falls. This movement may result in a broad vertical zone of dissolution at the water table above the conduit system, with thinner and more focused water-table dissolution at greater distance from the conduit.

  8. Stratigraphic and structural controls on groundwater flow in an outcropping fossil fan delta: the case of Sant Llorenç del Munt range (NE Spain)

    NASA Astrophysics Data System (ADS)

    Anglés, Marc; Folch, Albert; Oms, Oriol; Maestro, Eudald; Mas-Pla, Josep

    2017-12-01

    Hydrogeological models of mountain regions present the opportunity to understand the role of geological factors on groundwater resources. The effects of sedimentary facies and fracture distribution on groundwater flow and resource exploitation are studied in the ancient fan delta of Sant Llorenç de Munt (central Catalonia, Spain) by integrating geological field observations (using sequence stratigraphy methods) and hydrogeological data (pumping tests, hydrochemistry and environmental isotopes). A comprehensive analysis of data portrays the massif as a single unit, constituted by different compartments determined by specific layers and sets of fractures. Two distinct flow systems—local and regional—are identified based on pumping test analysis as well as hydrochemical and isotopic data. Drawdown curves derived from pumping tests indicate that the behavior of the saturated layers, whose main porosity is given by the fracture network, corresponds to a confined aquifer. Pumping tests also reflect a double porosity within the system and the occurrence of impervious boundaries that support a compartmentalized model for the whole aquifer system. Hydrochemical data and associated spatial evolution show the result of water-rock interaction along the flow lines. Concentration of magnesium, derived from dolomite dissolution, is a tracer of the flow-path along distinct stratigraphic units. Water stable isotopes indicate that evaporation (near a 5% loss) occurs in a thick unsaturated zone within the massif before infiltration reaches the water table. The hydrogeological analysis of this outcropping system provides a methodology for the conceptualization of groundwater flow in similar buried systems where logging and hydrogeological information are scarce.

  9. Transport behavior of groundwater protozoa and protozoan-sized microspheres in sandy aquifer sediments

    USGS Publications Warehouse

    Harvey, R.W.; Kinner, N.E.; Bunn, A.; MacDonald, D.; Metge, D.

    1995-01-01

    Transport behaviors of unidentified flagellated protozoa (flagellates) and flagellate-sized carboxylated microspheres in sandy, organically contaminated aquifer sediments were investigated in a small-scale (1 to 4-m travel distance) natural-gradient tracer test on Cape Cod and in flow-through columns packed with sieved (0.5-to 1.0-mm grain size) aquifer sediments. The minute (average in situ cell size, 2 to 3 ??m) flagellates, which are relatively abundant in the Cape Cod aquifer, were isolated from core samples, grown in a grass extract medium, labeled with hydroethidine (a vital eukaryotic stain), and coinjected into aquifer sediments along with bromide, a conservative tracer. The 2-??m flagellates appeared to be near the optimal size for transport, judging from flowthrough column experiments involving a polydispersed (0.7 to 6.2 ??m in diameter) suspension of carboxylated microspheres. However, immobilization within the aquifer sediments accounted for a log unit reduction over the first meter of travel compared with a log unit reduction over the first 10 m of travel for indigenous, free-living groundwater bacteria in earlier tests. High rates of flagellate immobilization in the presence of aquifer sediments also was observed in the laboratory. However, immobilization rates for the laboratory-grown flagellates (initially 4 to 5 ??m) injected into the aquifer were not constant and decreased noticeably with increasing time and distance of travel. The decrease in propensity for grain surfaces was accompanied by a decrease in cell size, as the flagellates presumably readapted to aquifer conditions. Retardation and apparent dispersion were generally at least twofold greater than those observed earlier for indigenous groundwater bacteria but were much closer to those observed for highly surface active carboxylated latex microspheres. Field and laboratory results suggest that 2- ??m carboxylated microspheres may be useful as analogs in investigating several abiotic aspects of flagellate transport behavior in groundwater.

  10. Multispecies reactive tracer test in an aquifer with spatially variable chemical conditions

    USGS Publications Warehouse

    Davis, J.A.; Kent, D.B.; Coston, J.A.; Hess, K.M.; Joye, J.L.

    2000-01-01

    A field investigation of multispecies reactive transport was conducted in a well‐characterized, sand and gravel aquifer on Cape Cod, Massachusetts. The aquifer is characterized by regions of differing chemical conditions caused by the disposal of secondary sewage effluent. Ten thousand liters of groundwater with added tracers (Br, Cr(VI), and EDTA complexed with Pb, Zn, Cu, and Ni) were injected into the aquifer and distributions of the tracers were monitored for 15 months. Most of the tracers were transported more than 200 m; transport was quantified using spatial moments computed from the results of a series of synoptic samplings. Cr(VI) transport was retarded relative to Br; the retardation factor varied from 1.1 to 2.4 and was dependent on chemical conditions. At 314 days after the injection, dissolved Cr(VI) mass in the tracer cloud had decreased 85%, with the likely cause being reduction to Cr(III) in a suboxic region of the aquifer. Transport of the metal‐EDTA complexes was affected by aqueous complexation, adsorption, and dissolution‐precipitation reactions of Fe oxyhydroxide minerals in the aquifer sediments. Dissolved Pb‐EDTA complexes disappeared from the tracer cloud within 85 days, probably due to metal exchange reactions with Fe and adsorbed Zn (present prior to the injection from contamination by the sewage effluent). About 30% of the Cu‐EDTA complexes remained within the tracer cloud 314 days after injection, even though the thermodynamic stability of the Pb‐EDTA complex is greater than Cu‐EDTA. It is hypothesized that stronger adsorption of Pb2+ to the aquifer sediments causes the Pb‐EDTA complex to disassociate to a greater degree than the Cu‐EDTA complex. The mass of dissolved Zn‐EDTA increased during the first 175 days of the tracer test to 140% of the mass injected, with the increase due to desorption of sewage‐derived Zn. Dissolved Ni‐EDTA mass remained nearly constant throughout the tracer test, apparently only participating in reversible adsorption reactions. The results of the field experiment provide a chemically complex data set that can be used in the testing of reactive transport models of flow coupled with chemical reactions.

  11. Retardation of ammonium and potassium transport through a contaminated sand and gravel aquifer: The Role of cation exchange

    USGS Publications Warehouse

    Ceazan, M.L.; Thurman, E.M.; Smith, R.L.

    1989-01-01

    The role of cation exchange in the retardation of ammonium (NH4+) and potassium (K+) transport in a shallow sand and gravel aquifer was evaluated by use of observed distributions of NH4+ and K+ within a plume of sewage-contaminated groundwater, small-scale tracer injection tests, and batch sorption experiments on aquifer material. Both NH4+ and K+ were transported ???2 km in the 4-km-long contaminant plume (retardation factor, Rf = 2.0). Sediments from the NH4+-containing zone of the plume contained significant quantities of KCl-extractable NH4+ (extraction distribution coefficient, Kd,extr = 0.59-0.87 mL/g of dry sediment), and when added to uncontaminated sediments, NH4+ sorption followed a linear isotherm. Small-scale tracer tests demonstrated that NH4+ and K+ were retarded (Rf =3.5) relative to a nonreactive tracer (Br-). Sorption of dissolved NH4+ was accompanied by concomitant release of calcium (Ca2+), magnesium (Mg2+), and sodium (Na+) from aquifer sediments, suggesting involvement of cation exchange. In contrast, nitrate (NO3-) was not retarded and cleanly separated from NH4+ and K+ in the small-scale tracer tests. This study demonstrates that transport of NH4+ and K+ through a sand and gravel aquifer can be markedly affected by cation-exchange processes even at a clay content less than 0.1%.

  12. Application of laboratory permeability data

    USGS Publications Warehouse

    Johnson, A.I.

    1963-01-01

    Some of the basic material contained in this report originally was prepared in 1952 as instructional handouts for ground-water short courses and for training of foreign participants. The material has been revised and expanded and is presented in the present form to make it more readily available to the field hydrologist. Illustrations now present published examples of the applications suggested in the 1952 material. For small areas, a field pumping test is sufficient to predict the characteristics of an aquifer. With a large area under study, the aquifer properties must be determined at many different locations and it is not usually economically feasible to make sufficient field tests to define the aquifer properties in detail for the whole aquifer. By supplementing a few field tests with laboratory permeability data and geologic interpretation, more point measurements representative of the hydrologic properties of the aquifer may be obtained. A sufficient number of samples seldom can be obtained to completely identify the permeability or transmissibility in detail for a project area. However, a few judiciously chosen samples of high quality, combined with good geologic interpretation, often will permit the extrapolation of permeability information over a large area with a fair degree of reliability. The importance of adequate geologic information, as well as the importance of collecting samples representative of at least all major textural units lying within the section or area of study, cannot be overemphasized.

  13. Estimating Hydraulic Parameters When Poroelastic Effects Are Significant

    USGS Publications Warehouse

    Berg, S.J.; Hsieh, P.A.; Illman, W.A.

    2011-01-01

    For almost 80 years, deformation-induced head changes caused by poroelastic effects have been observed during pumping tests in multilayered aquifer-aquitard systems. As water in the aquifer is released from compressive storage during pumping, the aquifer is deformed both in the horizontal and vertical directions. This deformation in the pumped aquifer causes deformation in the adjacent layers, resulting in changes in pore pressure that may produce drawdown curves that differ significantly from those predicted by traditional groundwater theory. Although these deformation-induced head changes have been analyzed in several studies by poroelasticity theory, there are at present no practical guidelines for the interpretation of pumping test data influenced by these effects. To investigate the impact that poroelastic effects during pumping tests have on the estimation of hydraulic parameters, we generate synthetic data for three different aquifer-aquitard settings using a poroelasticity model, and then analyze the synthetic data using type curves and parameter estimation techniques, both of which are based on traditional groundwater theory and do not account for poroelastic effects. Results show that even when poroelastic effects result in significant deformation-induced head changes, it is possible to obtain reasonable estimates of hydraulic parameters using methods based on traditional groundwater theory, as long as pumping is sufficiently long so that deformation-induced effects have largely dissipated. ?? 2011 The Author(s). Journal compilation ?? 2011 National Ground Water Association.

  14. Ground water in northeastern Louisville, Kentucky with reference to induced filtration

    USGS Publications Warehouse

    Rorabaugh, M.I.

    1956-01-01

    In cooperation with the city of Louisville, Ky., the U. S. Geological Survey made a detailed investigation during the period February 1945 to March 1947 of the ground-water resources of a 3-square-mile area along the Ohio River north-east of Louisville. Test drilling shows that the principal aquifer consists of about 80 feet of glacial-outwash sands and gravels lying in an old river channel which was cut into rocks of Ordovician, Silurian, and Devonian age. The total ground-water storage in the area is estimated as 7 billion gallons. The ground-water levels are affected by changes in river elevation, by rainfall, and by the effects of pumping in the downtown part of Louisville 3 miles to the southwest. In the northeastern part of the area the flow of ground water, as defined by contour maps, is toward the river, and in the southwestern part of the area it is from the river toward the downtown area of overpumping. Ground water in the area has an average temperature of 56° F. The water, which is moderately hard, is suitable for domestic and industrial uses. Analysis of a pumping test made during the investigation proves that infiltration supplies can be developed. Studies to determine the degree of connection between the river and aquifer were made on the basis of chemical analyses, sections showing temperature distribution in the aquifer during the pumping test, shapes of water-level profiles in the test area, and shapes of time-drawdown curves for a number of observation wells. Quantitative studies to evaluate the hydrologic constants of the aquifer were made by both graphical and mathematical methods. The transmissibility was determined as 121,000 gpd/ft in the test area; the distance to the line source, 400 feet; and the coefficient of storage, 0.0003. A comparison of river-level fluctuations and water-level fluctuations in observation wells shows that conditions along the 6.4-mile reach of river are not greatly different from those at the site of the pumping test. It is estimated that under adverse temperature and river-stage conditions infiltration supplies could be developed to the extent of 280 million gpd in the entire 6.4-mile reach investigated; at average river-water temperature (59° F) about 400 million gpd could be developed. Diagrams were drawn showing the estimated yield of wells of different radii, at various distances from the river, and at various spacings. In making the computations allowance was made for screen losses, dewatering of the aquifer, partial penetration of wells, location wells, eccentricity of large wells, and interference among wells.

  15. Finite Element Modeling of Transient Head Field Associated with Partially Penetrating, Slug Tests in a Heterogeneous Aquifer with Low Permeability, Stratigraphic Zones and Faults

    NASA Astrophysics Data System (ADS)

    Cheng, J.; Johnson, B.; Everett, M.

    2003-12-01

    Preliminary field work shows slug interference tests using an array of multilevel active and monitoring wells have potential of permitting enhanced aquifer characterization. Analysis of these test data, however, ultimately will rely on numerical geophysical inverse models. In order to gain insight as well as to provide synthetic data sets, we use a 3-D finite element analysis (code:FEHM-LANL) to explore the effect of idealized, low permeability, stratigraphical and structural (faults) heterogeneities on the transient head field associated with a slug test in a packer-isolated interval of an open borehole. The borehole and packers are modeled explicitly; wellbore storage is selected to match values of field tests. The homogeneous model exhibits excellent agreement with that of the semi-analytical model of Liu and Butler (1995). Models are axisymmetric with a centrally located slugged interval within a homogenous, isotropic, confined aquifer with embedded, horizontal or vertical zones of lower permeability that represent low permeability strata or faults, respectively. Either one or two horizontal layers are located opposite the borehole packers, which is a common situation at the field site; layer thickness (0.15-0.75 m), permeability contrast (up to 4 orders of magnitude contrast) and lateral continuity of layers are varied between models. The effect of a "hole" in a layer also is assessed. Fault models explore effects of thickness (0.05-0.75 m) and permeability contrast as well as additional effects associated with the offset of low permeability strata. Results of models are represented most clearly by contour maps of time of arrival and normalized amplitude of peak head perturbation, but transient head histories at selected locations provide additional insight. Synthesis of the models is on-going but a few points can be made at present. Spatial patterns are distinctive and allow easy discrimination between stratigraphic and structural impedance features. Time delays and amplitude reduction increase nonlinearly with increasing permeability contrast. The capacity to discriminate the effect of layer thickness decreases as permeability contrast increases.

  16. The use of pneumatically generated water pressure signals for aquifer characterization

    NASA Astrophysics Data System (ADS)

    Fort, M.; Roberts, R.; Chace, D.

    2013-12-01

    The use of pneumatically generated pressure signals for aquifer characterization Hydraulic tests are the most reliable method of obtaining estimates of hydrologic properties, such as conductivity, that are essential for flow and transport modeling. The use of a sinusoidal signal for hydraulic testing is well established, with Streltsova (1988), Rasmussen (2003) and others having developed analytic solutions. Sinusoidal tests provide a unique easily distinguished signal that reduces ambiguity during analysis and we show that a sinusoidal pressure signal propagates farther into the formation than a standard slug-test signal. If a sinusoidal test is combined with a slug and/or a constant rate test, it can further reduce uncertainty in the estimated parameter values. We demonstrate how pneumatic pressure can be used to generate all three of these signals. By positioning pressure transducers both below the water level and in the head space above the water, we can monitor the total pressure acting on the formation and the changes in water level. From the changes in water level, it is possible to calculate the flow rate in and out of the well, assuming that the well diameter and water density are known. Using gas flow controllers with a Supervisory Control And Data Acquisition (SCADA) system we are able to precisely control the pressures in the well. The use of pneumatic pressure has the advantage that it requires less equipment (no pumps) and produces no water. We also show how the numerical well test analysis program nSIGHTS can be used to analyze all three types of tests simultaneously and to assess the relative contribution of each type of test to the parameter estimation. nSIGHTS was recently released as open source by Sandia National Laboratories and is available for free.

  17. MOLECULAR ANALYSIS OF MICROBIAL COMMUNITY STRUCTURES IN PRISTINE AND CONTAMINATED AQUIFERS: FIELD AND LABORATORY MICROCOSM EXPERIMENTS

    EPA Science Inventory

    This study used phylogenetic probes in hybridization analysis to (i) determine in situ microbial community structures in regions of a shallow sand aquifer that were oxygen depleted and fuel contaminated (FC) or aerobic and noncontaminted (NC) and (ii) examine alterations in micro...

  18. Cost analysis of ground-water supplies in the North Atlantic region, 1970

    USGS Publications Warehouse

    Cederstrom, Dagfin John

    1973-01-01

    The cost of municipal and industrial ground water (or, more specifically, large supplies of ground water) at the wellhead in the North Atlantic Region in 1970 generally ranged from 1.5 to 5 cents per thousand gallons. Water from crystalline rocks and shale is relatively expensive. Water from sandstone is less so. Costs of water from sands and gravels in glaciated areas and from Coastal Plain sediments range from moderate to very low. In carbonate rocks costs range from low to fairly high. The cost of ground water at the wellhead is low in areas of productive aquifers, but owing to the cost of connecting pipe, costs increase significantly in multiple-well fields. In the North Atlantic Region, development of small to moderate supplies of ground water may offer favorable cost alternatives to planners, but large supplies of ground water for delivery to one point cannot generally be developed inexpensively. Well fields in the less productive aquifers may be limited by costs to 1 or 2 million gallons a day, but in the more favorable aquifers development of several tens of millions of gallons a day may be practicable and inexpensive. Cost evaluations presented cannot be applied to any one specific well or specific site because yields of wells in any one place will depend on the local geologic and hydrologic conditions; however, with such cost adjustments as may be necessary, the methodology presented should have wide applicability. Data given show the cost of water at the wellhead based on the average yield of several wells. The cost of water delivered by a well field includes costs of connecting pipe and of wells that have the yields and spacings specified. Cost of transport of water from the well field to point of consumption and possible cost of treatment are not evaluated. In the methodology employed, costs of drilling and testing, pumping equipment, engineering for the well field, amortization at 5% percent interest, maintenance, and cost of power are considered. The report includes an analysis of test drilling costs leading to a production well field. The discussion shows that test drilling is a relatively low cost item and that more than a minimum of test holes in a previously unexplored area is, above all, simple insurance in keeping down costs and may easily result in final lower costs for the system. Use of the jet drill for testing is considered short sighted and may result in higher total costs and possibly failure to discover good aquifers. Economic development of ground water supplies will depend on obtaining qualified hydrologic and engineering advice, on carrying out adequate test drilling, and on utilizing high-quality (at times, more costly) material.

  19. Public Health Risk Conditioned by Chemical Composition of Ground Water

    NASA Astrophysics Data System (ADS)

    Yankovich, E.; Osipova, N.; Yankovich, K.; Matveenko, I.

    2016-03-01

    The article studies the public health potential risk originated from water consumption and estimated on the basis of the groundwater chemical composition. We have processed the results of chemical groundwater analysis in different aquifers of Tomsk district (Tomsk Oblast, Russia). More than 8400 samples of chemical groundwater analyses were taken during long-term observation period. Human health risk assessment of exposure to contaminants in drinking water was performed in accordance with the risk assessment guidance for public health concerning chemical pollution of the environment (Russian reference number: 2.1.10.1920-04-M, 2004). Identified potential risks were estimated for consuming water of each aquifer. The comparative analysis of water quality of different aquifers was performed on the basis of the risk coefficient of the total non-carcinogenic effects. The non-carcinogenic risk for the health of the Tomsk district population due to groundwater consumption without prior sanitary treatment was admitted acceptable. A rather similar picture is observed for all aquifers, although deeper aquifers show lower hazard coefficients.

  20. Specific Yields Estimated from Gravity Change during Pumping Test

    NASA Astrophysics Data System (ADS)

    Chen, K. H.; Hwang, C.; Chang, L. C.

    2017-12-01

    Specific yield (Sy) is the most important parameter to describe available groundwater capacity in an unconfined aquifer. When estimating Sy by a field pumping test, aquifer heterogeneity and well performers will cause a large uncertainty. In this study, we use a gravity-based method to estimate Sy. At the time of pumping test, amounts of mass (groundwater) are forced to be taken out. If drawdown corn is big and close enough to high precision gravimeter, the gravity change can be detected. The gravity-based method use gravity observations that are independent from traditional flow computation. Only the drawdown corn should be modeled with observed head and hydrogeology data. The gravity method can be used in most groundwater field tests, such as locally pumping/injection tests initiated by active man-made or annual variations due to natural sources. We apply our gravity method at few sites in Taiwan situated over different unconfined aquifer. Here pumping tests for Sy determinations were also carried out. We will discuss why the gravity method produces different results from traditional pumping test, field designs and limitations of the gravity method.

  1. Hydrogeology and ground-water flow of the drift and Platteville aquifer system, St Louis Park, Minnesota

    USGS Publications Warehouse

    Lindgren, R.J.

    1995-01-01

    Model simulations indicate that vertical ground-water flow from the drift aquifers and from the Platteville aquifer to underlying bedrock aquifers is greatest through bedrock valleys. The convergence of flow paths near bedrock valleys and the greater volume of water moving through the valleys would likely result in both increased concentrations and greater vertical movement of contaminants in areas underlain by bedrock valleys as compared to areas not underlain by bedrock valleys. Model results also indicate that field measurements of hydraulic head might not help locate discontinuities in confining units and additional test drilling to locate discontinuities might be necessary.

  2. Analysis of flow near a dug well in an unconfined aquifer

    NASA Astrophysics Data System (ADS)

    Sridharan, K.; Sathyanarayana, D.; Reddy, A. Siva

    1990-11-01

    A numerical analysis of flow to a dug well in an unconfined aquifer is made, taking into account well storage, elastic storage release, gravity drainage, anisotropy, partial penetration, vertical flow and seepage surface at the well face, and treating the water table in the aquifer and water level in the well as unknown boundaries. The pumped discharge is maintained constant. The solution is obtained by a two-level iterative scheme. The effects of governing parameters on the drawdown, development of seepage surface and contribution from aquifer flow to the total discharge are discussed. The degree of anisotropy and partial penetration are found to be the parameters which affect the flow characteristics most significantly. The effect of anisotropy on the development of seepage surface is very pronounced.

  3. Interpretation of well logs in a carbonate aquifer

    USGS Publications Warehouse

    MacCary, L.M.

    1978-01-01

    This report describes the log analysis of the Randolph and Sabial core holes in the Edwards aquifer in Texas, with particular attention to the principles that can be applied generally to any carbonate system. The geologic and hydrologic data were obtained during the drilling of the two holes, from extensive laboratory analysis of the cores, and from numerous geophysical logs run in the two holes. Some logging methods are inherently superiors to others for the analysis of limestone and dolomite aquifers. Three such systems are the dentistry, neutron, and acoustic-velocity (sonic) logs. Most of the log analysis described here is based on the interpretation of suites of logs from these three systems. In certain instances, deeply focused resistivity logs can be used to good advantage in carbonate rock studies; this technique is used to computer the water resistivity in the Randolph core hole. The rocks penetrated by the Randolph core hole are typical of those carbonates that have undergone very little solution by recent ground-water circulation. There are few large solutional openings; the water is saline; and the rocks are dark, dolomitic, have pore space that is interparticle or intercrystalline, and contain unoxidized organic material. The total porosity of rocks in the saline zone is higher than that of rocks in the fresh-water aquifer; however, the intrinsic permeability is much less in the saline zone because there are fewer large solutional openings. The Sabinal core hole penetrates a carbonate environment that has experienced much solution by ground water during recent geologic time. The rocks have high secondary porosities controlled by sedimentary structures within the rock; the water is fresh; and the dominant rock composition is limestone. The relative percentages of limestone and dolomite, the average matrix (grain) densities of the rock mixtures , and the porosity of the rock mass can be calculated from density, neutron, and acoustic logs. With supporting data from resistivity logs, the formation water quality can be estimated, as well as the relative cementation or tortuosity of the rock. Many of these properties calculated from logs can be verified by analysis of the core available from test holes drilled in the saline and fresh water zones.

  4. Sequence-Stratigraphic Analysis of the Regional Observation Monitoring Program (ROMP) 29A Test Corehole and Its Relation to Carbonate Porosity and Regional Transmissivity in the Floridan Aquifer System, Highlands County, Florida

    USGS Publications Warehouse

    Ward, W. C.; Cunningham, K.J.; Renken, R.A.; Wacker, M.A.; Carlson, J.I.

    2003-01-01

    An analysis was made to describe and interpret the lithology of a part of the Upper Floridan aquifer penetrated by the Regional Observation Monitoring Program (ROMP) 29A test corehole in Highlands County, Florida. This information was integrated into a one-dimensional hydrostratigraphic model that delineates candidate flow zones and confining units in the context of sequence stratigraphy. Results from this test corehole will serve as a starting point to build a robust three-dimensional sequence-stratigraphic framework of the Floridan aquifer system. The ROMP 29A test corehole penetrated the Avon Park Formation, Ocala Limestone, Suwannee Limestone, and Hawthorn Group of middle Eocene to Pliocene age. The part of the Avon Park Formation penetrated in the ROMP 29A test corehole contains two composite depositional sequences. A transgressive systems tract and a highstand systems tract were interpreted for the upper composite sequence; however, only a highstand systems tract was interpreted for the lower composite sequence of the deeper Avon Park stratigraphic section. The composite depositional sequences are composed of at least five high-frequency depositional sequences. These sequences contain high-frequency cycle sets that are an amalgamation of vertically stacked high-frequency cycles. Three types of high-frequency cycles have been identified in the Avon Park Formation: peritidal, shallow subtidal, and deeper subtidal high-frequency cycles. The vertical distribution of carbonate-rock diffuse flow zones within the Avon Park Formation is heterogeneous. Porous vuggy intervals are less than 10 feet, and most are much thinner. The volumetric arrangement of the diffuse flow zones shows that most occur in the highstand systems tract of the lower composite sequence of the Avon Park Formation as compared to the upper composite sequence, which contains both a backstepping transgressive systems tract and a prograding highstand systems tract. Although the porous and permeable layers are not thick, some intervals may exhibit lateral continuity because of their deposition on a broad low-relief ramp. A thick interval of thin vuggy zones and open faults forms thin conduit flow zones mixed with relatively thicker carbonate-rock diffuse flow zones between a depth of 1,070 and 1,244 feet below land surface (bottom of the test corehole). This interval is the most transmissive part of the Avon Park Formation penetrated in the ROMP 29A test corehole and is included in the highstand systems tract of the lower composite sequence. The Ocala Limestone is considered to be a semiconfining unit and contains three depositional sequences penetrated by the ROMP 29A test corehole. Deposited within deeper subtidal depositional cycles, no zones of enhanced porosity and permeability are expected in the Ocala Limestone. A thin erosional remnant of the shallow marine Suwannee Limestone overlies the Ocala Limestone, and permeability seems to be comparatively low because moldic porosity is poorly connected. Rocks that comprise the lower Hawthorn Group, Suwannee Limestone, and Ocala Limestone form a permeable upper zone of the Upper Floridan aquifer, and rocks of the lower Ocala Limestone and Avon Park Formation form a permeable lower zone of the Upper Floridan aquifer. On the basis of a preliminary analysis of transmissivity estimates for wells located north of Lake Okeechobee, spatial relations among groups of relatively high and low transmissivity values within the upper zone are evident. Upper zone transmissivity is generally less than 10,000 feet squared per day in areas located south of a line that extends through Charlotte, Sarasota, DeSoto, Highlands, Polk, Osceola, Okeechobee, and St. Lucie Counties. Transmissivity patterns within the lower zone of the Avon Park Formation cannot be regionally assessed because insufficient data over a wide areal extent have not been compiled.

  5. Characterization of a high-transmissivity zone by well test analysis: Steady state case

    USGS Publications Warehouse

    Tiedeman, Claire; Hsieh, Paul A.; Christian, Sarah B.

    1995-01-01

    A method is developed to analyze steady horizontal flow to a well pumped from a confined aquifer composed of two homogeneous zones with contrasting transmissivities. Zone 1 is laterally unbounded and encloses zone 2, which is elliptical in shape and is several orders of magnitude more transmissive than zone 1. The solution for head is obtained by the boundary integral equation method. Nonlinear least squares regression is used to estimate the model parameters, which include the transmissivity of zone 1, and the location, size, and orientation of zone 2. The method is applied to a hypothetical aquifer where zone 2 is a long and narrow zone of vertical fractures. Synthetic data are generated from three different well patterns, representing different areal coverage and proximity to the fracture zone. When zone 1 of the hypothetical aquifer is homogeneous, the method correctly estimates all model parameters. When zone 1 is a randomly heterogeneous transmissivity field, some parameter estimates, especially the length of zone 2, become highly uncertain. To reduce uncertainty, the pumped well should be close to the fracture zone, and surrounding observation wells should cover an area similar in dimension to the length of the fracture zone. Some prior knowledge of the fracture zone, such as that gained from a surface geophysical survey, would greatly aid in designing the well test.

  6. Empirical analysis of the stress-strain relationship between hydraulic head and subsidence in the San Joaquin Valley Aquifer

    NASA Astrophysics Data System (ADS)

    Neff, K. L.; Farr, T.

    2016-12-01

    Aquifer subsidence due to groundwater abstraction poses a significant threat to aquifer sustainability and infrastructure. The need to prevent permanent compaction to preserve aquifer storage capacity and protect infrastructure begs a better understanding of how compaction is related to groundwater abstraction and aquifer hydrogeology. The stress-strain relationship between hydraulic head changes and aquifer compaction has previously been observed to be hysteretic in both empirical and modeling studies. Here, subsidence data for central California's San Joaquin Valley derived from interferometric synthetic aperture radar (InSAR) for the period 2007-2016 is examined relative to hydraulic head levels in monitoring and production wells collected by the California Department of Water Resources. Such a large and long-term data set is available for empirical analysis for the first time thanks to advances in InSAR data collection and geospatial data management. The California Department of Water Resources (DWR) funded this work to provide the background and an update on subsidence in the Central Valley to support future policy. Part of this work was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA.

  7. Changes in chloride concentration in water from municipal wells that tap aquifers in rocks of Cambrian and Ordovician age in northeastern Illinois, 1915-84

    USGS Publications Warehouse

    Balding, G.O.

    1991-01-01

    During the past few decades, several municipalities in northeastern Illinois have noted increases in the salinity of water from wells that tap aquifers in rocks of Cambrian and Ordovician age. The municipalities have discontinued the use of, or sealed-off sections of, those wells. The aquifers involved include the Ancell, the Ironton-Galesville, and the Elmhurst-Mt. Simon. To define the location, magnitude, and possible causes for the salinity increases in the six northeastern counties of Illinois, 17 municipal wells and 1 deep test well were selected on the basis of their proximity to major pumping centers, the availability of water-quality data, and their documented maintenance history. Well depths ranged from about 960 to 3,475 feet. One well was finished in the middle confining unit, 2 wells were finished in the Ironton-Galesville aquifer, 4 wells were finished in the Eau Claire confining unit, and 10 wells were finished in the Elmhurst-Mt. Simon aquifer. The deep test well was finished below the Elmhurst-Mt. Simon aquifer in Precambrian-age rock. Chloride concentrations in the municipal wells ranged from less than 5 to greater than 600 milligrams per liter; in the deep test well, they ranged from 13 t o 37,000 milligrams per liter. Some changes in the chloride concentration in water from the studied municipal wells can be related to physical changes to the wells, including the partial filling in of a well, bridging within a well, the cleaning out of a well, or the deepening of a well. Some changes in chloride concentration are not related to physical changes but may be caused by increased pumpage; changes in pumping rate, frequency, or duration; cessation of pumping; improper abandonment of wells; and the upconing of highly mineralized water. The data base was inadequate for a quantitative study of the changes in chloride concentration in water from individual aquifers in rocks of Cambrian and Ordovician age.

  8. Hydrologic effects of stress-relief fracturing in an Appalachian Valley

    USGS Publications Warehouse

    Wyrick, Granville G.; Borchers, James W.

    1981-01-01

    A hydrologic study at Twin Falls State Park, Wyoming County, West Virginia, was made to determine how fracture systems affect the occurrence and movement of ground water in a typical valley of the Appalachian Plateaus Physiographic Province. Twin Falls was selected because it is generally unaffected by factors that would complicate an analysis of the data. The study area was the Black Fork Valley at Twin Falls. The valley is about 3 miles long and 400 to 600 feet wide and is cut into massive sandstone units interbedded with thin coal and shale beds. The study was made to determine how aquifer characteristics were related to fracture systems in this valley, so that the relation could be applied to studies of other valleys. Two sites were selected for test drilling, pumping tests, and geophysical studies. One site is in the upper part of the valley, and the second is near the lower central part. At both sites, ground water occurs mainly in horizontal bedding-plane fractures under the valley floor and in nearly vertical and horizontal slump fractures along the valley wall. The aquifer is under confined conditions under the valley floor and unconfined conditions along the valley wall. The fractures pinch out under the valley walls, which form impermeable barriers. Tests of wells near the valley center indicated a change in storage coefficient as the cone of depression caused by pumping reached the confined-unconfined boundaries; the tests also indicated barrier-image effects when the cone reached the impermeable boundaries. Drawdown from pumping near the center of the valley affected water levels at both sites, indicating a hydraulic connection from the upper to the lower end of the valley. Stream gain-and-loss studies show that ground water discharges to the stream from horizontal fractures beneath Black Fork Falls, near the mouth of Black Fork. The fracture systems that constitute most of the transmissive part of the aquifer at Twin Falls are like those described as being formed from stress relief. As stress-relief fractures have been described in other valleys of the Appalachian Plateaus, the same aquifer conditions may exist in those valleys.

  9. Pumping Test Determination of Unsaturated Aquifer Properties

    NASA Astrophysics Data System (ADS)

    Mishra, P. K.; Neuman, S. P.

    2008-12-01

    Tartakovsky and Neuman [2007] presented a new analytical solution for flow to a partially penetrating well pumping at a constant rate from a compressible unconfined aquifer considering the unsaturated zone. In their solution three-dimensional, axially symmetric unsaturated flow is described by a linearized version of Richards' equation in which both hydraulic conductivity and water content vary exponentially with incremental capillary pressure head relative to its air entry value, the latter defining the interface between the saturated and unsaturated zones. Both exponential functions are characterized by a common exponent k having the dimension of inverse length, or equivalently a dimensionless exponent kd=kb where b is initial saturated thickness. The authors used their solution to analyze drawdown data from a pumping test conducted by Moench et al. [2001] in a Glacial Outwash Deposit at Cape Cod, Massachusetts. Their analysis yielded estimates of horizontal and vertical saturated hydraulic conductivities, specific storage, specific yield and k . Recognizing that hydraulic conductivity and water content seldom vary identically with incremental capillary pressure head, as assumed by Tartakovsky and Neuman [2007], we note that k is at best an effective rather than a directly measurable soil parameter. We therefore ask to what extent does interpretation of a pumping test based on the Tartakovsky-Neuman solution allow estimating aquifer unsaturated parameters as described by more common constitutive water retention and relative hydraulic conductivity models such as those of Brooks and Corey [1964] or van Genuchten [1980] and Mualem [1976a]? We address this question by showing how may be used to estimate the capillary air entry pressure head k and the parameters of such constitutive models directly, without a need for inverse unsaturated numerical simulations of the kind described by Moench [2003]. To assess the validity of such direct estimates we use maximum likelihood- based model selection criteria to compare the abilities of numerical models based on the STOMP code to reproduce observed drawdowns during the test when saturated and unsaturated aquifer parameters are estimated either in the above manner or by means of the inverse code PEST.

  10. Inferring field-scale properties of a fractured aquifer from ground surface deformation during a well test

    NASA Astrophysics Data System (ADS)

    Schuite, Jonathan; Longuevergne, Laurent; Bour, Olivier; Boudin, Frédérick; Durand, Stéphane; Lavenant, Nicolas

    2015-12-01

    Fractured aquifers which bear valuable water resources are often difficult to characterize with classical hydrogeological tools due to their intrinsic heterogeneities. Here we implement ground surface deformation tools (tiltmetry and optical leveling) to monitor groundwater pressure changes induced by a classical hydraulic test at the Ploemeur observatory. By jointly analyzing complementary time constraining data (tilt) and spatially constraining data (vertical displacement), our results strongly suggest that the use of these surface deformation observations allows for estimating storativity and structural properties (dip, root depth, and lateral extension) of a large hydraulically active fracture, in good agreement with previous studies. Hence, we demonstrate that ground surface deformation is a useful addition to traditional hydrogeological techniques and opens possibilities for characterizing important large-scale properties of fractured aquifers with short-term well tests as a controlled forcing.

  11. Methods and applications of electrical simulation in ground-water studies in the lower Arkansas and Verdigris River Valleys, Arkansas and Oklahoma

    USGS Publications Warehouse

    Bedinger, M.S.; Reed, J.E.; Wells, C.J.; Swafford, B.F.

    1970-01-01

    The Arkansas River Multiple-Purpose Plan will provide year-round navigation on the Arkansas River from near its mouth to Muskogee, Okla., and on the Verdigris River from Muskogee to Catoosa, Okla. The altered regimen in the Arkansas and Verdigris Rivers will affect ground-water conditions in the adjacent alluvial aquifers. In 1957 the U.S. Geological Survey and U.S. Army Corps of Engineers entered into a cooperative agreement for a comprehensive ground-water study of the lower Arkansas and Verdigris River valleys. At the request of the Corps of Engineers, the Geological Survey agreed to provide (1) basic ground-water data before, during, and after construction of the Multiple-Purpose Plan and (2) interpretation and projections of postconstruction ground-water conditions. The data collected were used by the Corps of Engineers in preliminary foundation and excavation estimates and by the Geological Survey as the basis for defining the hydrologic properties of, and the ground-water conditions in, the aquifer. The projections of postconstruction ground-water conditions were used by the Corps of Engineers in the planning, design, construction, and operation of the Multiple-Purpose Plan. Analysis and projections of ground-water conditions were made by use of electrical analog models. These models use the analogy between the flow of electricity in a resistance-capacitance circuit and the flow of a liquid in a porous and permeable medium. Verification provides a test of the validity of the analog to perform as the aquifer would, within the range of historic forces. The verification process consists of simulating the action of historic forces which have acted upon the aquifer and of duplicating the aquifer response with the analog. The areal distribution of accretion can be treated as an unknown and can be determined by analog simulation of the piezometric surface in an aquifer. Comparison of accretion with depth to piezometric surface below land surface shows that accretion decreases with decreasing depth to water level. The decrease in accretion is attributed mostly to the increase in evapotranspiration from the aquifer, and where water levels are very near the land surface, to the rejection of recharge. The maximum accretion and the decrease in accretion with the decrease in depth to water are dependent upon the climate and the thickness and lithology of the fine-grained material overlying the aquifer. Dams on the Arkansas and Verdigris Rivers will impose a direct change in water levels in the aquifers adjacent to the rivers. This change will be attenuated by the resultant change in accretion to the aquifer. The analogs of aquifers in the valleys were used to determine the change in ground-water level from preconstruction to postconstruction conditions.

  12. Characterization of California Central Coast Aquifers using Pneumatic Slug Tests

    NASA Astrophysics Data System (ADS)

    Aurelius, S.; Platt, D.; Whetsler, B.; Malama, B.

    2017-12-01

    The recent prolonged drought in California, where about 75% of the population depends to some extent ongroundwater, has led to increased stresses on the state's groundwater resources due to reduced recharge andincreased abstraction to supplement dwindling surface water supplies for irrigation and other urban uses.These factors have conspired to cause historic lows in groundwater levels, lost aquifer storage capacity dueincreased potential for land subsidence, and degraded water quality in coastal aquifers faced with increasedrates of seawater intrusion. Groundwater accounts for about a third of the total water uses in California,with some coastal communities being 100% dependent on groundwater. Irrigation accounts for over 60%of all state groundwater withdrawals in California. In light of this, the state of California recently passedthe Sustainable Groundwater Management Act (SGMA) aimed at bringing the State's groundwater basinsinto sustainable regimes of abstraction, recharge and storage. Groundwater ow models are critical to thesuccessful implementation of the SGMA legislation. However, the usefulness of the models is severely limitedby a lack of detailed knowledge of aquifer properties at spatial scales that allow for accurate projections tobe made about groundwater basin sustainability by resource managers. We report here the results of highresolution pneumatic slug tests performed in two shallow aquifers in San Luis Obispo County on the CaliforniaCentral Coast to obtain detailed information about aquifer properties, including permeability and storage,and their spatial variability.

  13. On the classification of seawater intrusion

    NASA Astrophysics Data System (ADS)

    Werner, Adrian D.

    2017-08-01

    Seawater intrusion (SWI) arising from aquifer depletion is often classified as ;active; or ;passive;, depending on whether seawater moves in the same direction as groundwater flow or not. However, recent studies have demonstrated that alternative forms of active SWI show distinctly different characteristics, to the degree that the term ;active SWI; may be misleading without additional qualification. In response, this article proposes to modify hydrogeology lexicon by defining and characterizing three classes of SWI, namely passive SWI, passive-active SWI and active SWI. The threshold parameter combinations for the onset of each form of SWI are developed using sharp-interface, steady-state analytical solutions. Numerical simulation is then applied to a hypothetical case study to test the developed theory and to provide additional insights into dispersive SWI behavior. The results indicate that the three classes of SWI are readily predictable, with the exception of active SWI occurring in the presence of distributed recharge. The key characteristics of each SWI class are described to distinguish their most defining features. For example, active SWI occurring in aquifers receiving distributed recharge only creates watertable salinization downstream of the groundwater mound and only where dispersion effects are significant. The revised classification of SWI proposed in this article, along with the analysis of thresholds and SWI characteristics, provides coastal aquifer custodians with an improved basis upon which to expect salinization mechanisms to impact freshwater availability following aquifer depletion.

  14. Arsenic-Safe Aquifers in Coastal Bangladesh: AN Investigation with Ordinary Kriging Estimation

    NASA Astrophysics Data System (ADS)

    Hassan, M. M.; Ahamed, R.

    2017-10-01

    Spatial point pattern is one of the most suitable methods for analysing groundwater arsenic concentrations. Groundwater arsenic poisoning in Bangladesh has been one of the biggest environmental health disasters in recent times. About 85 million people are exposed to arsenic more than 50 μg/L in drinking water. The paper seeks to identify the existing suitable aquifers for arsenic-safe drinking water along with "spatial arsenic discontinuity" using GIS-based spatial geostatistical analysis in a small study site (12.69 km2) in the coastal belt of southwest Bangladesh (Dhopakhali union of Bagerhat district). The relevant spatial data were collected with Geographical Positioning Systems (GPS), arsenic data with field testing kits, tubewell attributes with observation and questionnaire survey. Geostatistics with kriging methods can design water quality monitoring in different aquifers with hydrochemical evaluation by spatial mapping. The paper presents the interpolation of the regional estimates of arsenic data for spatial discontinuity mapping with Ordinary Kriging (OK) method that overcomes the areal bias problem for administrative boundary. This paper also demonstrates the suitability of isopleth maps that is easier to read than choropleth maps. The OK method investigated that around 80 percent of the study site are contaminated following the Bangladesh Drinking Water Standards (BDWS) of 50 μg/L. The study identified a very few scattered "pockets" of arsenic-safe zone at the shallow aquifer.

  15. A Lagging Model for Describing Drawdown Induced by a Constant-Rate Pumping in a Leaky Confined Aquifer

    NASA Astrophysics Data System (ADS)

    Lin, Ye-Chen; Yeh, Hund-Der

    2017-10-01

    This study proposes a generalized Darcy's law with considering phase lags in both the water flux and drawdown gradient to develop a lagging flow model for describing drawdown induced by constant-rate pumping (CRP) in a leaky confined aquifer. The present model has a mathematical formulation similar to the dual-porosity model. The Laplace-domain solution of the model with the effect of wellbore storage is derived by the Laplace transform method. The time-domain solution for the case of neglecting the wellbore storage and well radius is developed by the use of Laplace transform and Weber transform. The results of sensitivity analysis based on the solution indicate that the drawdown is very sensitive to the change in each of the transmissivity and storativity. Also, a study for the lagging effect on the drawdown indicates that its influence is significant associated with the lag times. The present solution is also employed to analyze a data set taken from a CRP test conducted in a fractured aquifer in South Dakota, USA. The results show the prediction of this new solution with considering the phase lags has very good fit to the field data, especially at early pumping time. In addition, the phase lags seem to have a scale effect as indicated in the results. In other words, the lagging behavior is positively correlated with the observed distance in the Madison aquifer.

  16. Modelling an induced thermal plume with data from electrical resistivity tomography and distributed temperature sensing: a case study in northeast Italy

    NASA Astrophysics Data System (ADS)

    Cultrera, Matteo; Boaga, Jacopo; Di Sipio, Eloisa; Dalla Santa, Giorgia; De Seta, Massimiliano; Galgaro, Antonio

    2018-05-01

    Groundwater tracer tests are often used to improve aquifer characterization, but they present several disadvantages, such as the need to pour solutions or dyes into the aquifer system and alteration of the water's chemical properties. Thus, tracers can affect the groundwater flow mechanics and data interpretation becomes more complex, hindering effective study of ground heat pumps for low enthalpy geothermal systems. This paper presents a preliminary methodology based on a multidisciplinary application of heat as a tracer for defining the main parameters of shallow aquifers. The field monitoring techniques electrical resistivity tomography (ERT) and distributed temperature sensing (DTS) are noninvasive and were applied to a shallow-aquifer test site in northeast Italy. The combination of these measurement techniques supports the definition of the main aquifer parameters and therefore the construction of a reliable conceptual model, which is then described through the numerical code FEFLOW. This model is calibrated with DTS and validated by ERT outcomes. The reliability of the numerical model in terms of fate and transport is thereby enhanced, leading to the potential for better environmental management and protection of groundwater resources through more cost-effective solutions.

  17. Permeability profiles in granular aquifers using flowmeters in direct-push wells

    USGS Publications Warehouse

    Paradis, D.; Lefebvre, R.; Morin, R.H.; Gloaguen, E.

    2010-01-01

    Numerical hydrogeological models should ideally be based on the spatial distribution of hydraulic conductivity (K), a property rarely defined on the basis of sufficient data due to the lack of efficient characterization methods. Electromagnetic borehole flowmeter measurements during pumping in uncased wells can effectively provide a continuous vertical distribution of K in consolidated rocks. However, relatively few studies have used the flowmeter in screened wells penetrating unconsolidated aquifers, and tests conducted in gravel-packed wells have shown that flowmeter data may yield misleading results. This paper describes the practical application of flowmeter profiles in direct-push wells to measure K and delineate hydrofacies in heterogeneous unconsolidated aquifers having low-to-moderate K (10−6 to 10−4 m/s). The effect of direct-push well installation on K measurements in unconsolidated deposits is first assessed based on the previous work indicating that such installations minimize disturbance to the aquifer fabric. The installation and development of long-screen wells are then used in a case study validating Kprofiles from flowmeter tests at high-resolution intervals (15 cm) with K profiles derived from multilevel slug tests between packers at identical intervals. For 119 intervals tested in five different wells, the difference in log K values obtained from the two methods is consistently below 10%. Finally, a graphical approach to the interpretation of flowmeter profiles is proposed to delineate intervals corresponding to distinct hydrofacies, thus providing a method whereby both the scale and magnitude of K contrasts in heterogeneous unconsolidated aquifers may be represented.

  18. Arsenic control during aquifer storage recovery cycle tests in the Floridan Aquifer.

    PubMed

    Mirecki, June E; Bennett, Michael W; López-Baláez, Marie C

    2013-01-01

    Implementation of aquifer storage recovery (ASR) for water resource management in Florida is impeded by arsenic mobilization. Arsenic, released by pyrite oxidation during the recharge phase, sometimes results in groundwater concentrations that exceed the 10 µg/L criterion defined in the Safe Drinking Water Act. ASR was proposed as a major storage component for the Comprehensive Everglades Restoration Plan (CERP), in which excess surface water is stored during the wet season, and then distributed during the dry season for ecosystem restoration. To evaluate ASR system performance for CERP goals, three cycle tests were conducted, with extensive water-quality monitoring in the Upper Floridan Aquifer (UFA) at the Kissimmee River ASR (KRASR) pilot system. During each cycle test, redox evolution from sub-oxic to sulfate-reducing conditions occurs in the UFA storage zone, as indicated by decreasing Fe(2+) /H2 S mass ratios. Arsenic, released by pyrite oxidation during recharge, is sequestered during storage and recovery by co-precipitation with iron sulfide. Mineral saturation indices indicate that amorphous iron oxide (a sorption surface for arsenic) is stable only during oxic and sub-oxic conditions of the recharge phase, but iron sulfide (which co-precipitates arsenic) is stable during the sulfate-reducing conditions of the storage and recovery phases. Resultant arsenic concentrations in recovered water are below the 10 µg/L regulatory criterion during cycle tests 2 and 3. The arsenic sequestration process is appropriate for other ASR systems that recharge treated surface water into a sulfate-reducing aquifer. Published 2012. This article is a U.S. Government work and is in the public domain in the USA.

  19. Permeability profiles in granular aquifers using flowmeters in direct-push wells.

    PubMed

    Paradis, Daniel; Lefebvre, René; Morin, Roger H; Gloaguen, Erwan

    2011-01-01

    Numerical hydrogeological models should ideally be based on the spatial distribution of hydraulic conductivity (K), a property rarely defined on the basis of sufficient data due to the lack of efficient characterization methods. Electromagnetic borehole flowmeter measurements during pumping in uncased wells can effectively provide a continuous vertical distribution of K in consolidated rocks. However, relatively few studies have used the flowmeter in screened wells penetrating unconsolidated aquifers, and tests conducted in gravel-packed wells have shown that flowmeter data may yield misleading results. This paper describes the practical application of flowmeter profiles in direct-push wells to measure K and delineate hydrofacies in heterogeneous unconsolidated aquifers having low-to-moderate K (10(-6) to 10(-4) m/s). The effect of direct-push well installation on K measurements in unconsolidated deposits is first assessed based on the previous work indicating that such installations minimize disturbance to the aquifer fabric. The installation and development of long-screen wells are then used in a case study validating K profiles from flowmeter tests at high-resolution intervals (15 cm) with K profiles derived from multilevel slug tests between packers at identical intervals. For 119 intervals tested in five different wells, the difference in log K values obtained from the two methods is consistently below 10%. Finally, a graphical approach to the interpretation of flowmeter profiles is proposed to delineate intervals corresponding to distinct hydrofacies, thus providing a method whereby both the scale and magnitude of K contrasts in heterogeneous unconsolidated aquifers may be represented. Journal compilation © 2010 National Ground Water Association. No claim to original US government works.

  20. Evaluating degradation of hexachlorcyclohexane (HCH) isomers within a contaminated aquifer using compound-specific stable carbon isotope analysis (CSIA).

    PubMed

    Bashir, Safdar; Hitzfeld, Kristina L; Gehre, Matthias; Richnow, Hans H; Fischer, Anko

    2015-03-15

    The applicability of compound-specific stable carbon isotope analysis (CSIA) for assessing biodegradation of hexachlorocyclohexane (HCH) isomers was investigated in a contaminated aquifer at a former pesticide processing facility. A CSIA method was developed and tested for efficacy in determining carbon isotope ratios of HCH isomers in groundwater samples using gas chromatography - isotope ratio mass spectrometry (GC-IRMS). The carbon isotope ratios of HCHs measured for samples taken from the field site confirmed contaminant source zones at former processing facilities, a storage depot and a waste dump site. The (13)C-enrichment in HCHs provided evidence for biodegradation of HCHs especially downstream of the contaminant source zones. CSIA from monitoring campaigns in 2008, 2009 and 2010 revealed temporal trends in HCH biodegradation. Thus, the impact and progress of natural attenuation processes could be evaluated within the investigated aquifer. Calculations based on the Rayleigh-equation approach yielded levels of HCH biodegradation ranging from 30 to 86 %. Moreover, time- and distance-dependent in situ first-order biodegradation rate constants were estimated with maximal values of 3 × 10(-3) d(-1) and 10 × 10(-3) m(-1) for α-HCH, 11 × 10(-3) d(-1) and 37 × 10(-3) m(-1) for β-HCH, and 6 × 10(-3) d(-1) and 19 × 10(-3) m(-1) for δ-HCH, respectively. This study highlights the applicability of CSIA for the assessment of HCH biodegradation within contaminated aquifers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Quasi-horizontal circulation cells in 3D seawater intrusion

    USGS Publications Warehouse

    Abarca, E.; Carrera, J.; Sanchez-Vila, X.; Voss, C.I.

    2007-01-01

    The seawater intrusion process is characterized by the difference in freshwater and seawater density that causes freshwater to float on seawater. Many confined aquifers have a large horizontal extension with respect to thickness. In these cases, while buoyancy acts in the vertical direction, flow is confined between the upper and bottom boundaries and the effect of gravity is controlled by variations of aquifer elevation. Therefore, the effective gravity is controlled by the slope and the shape of the aquifer boundaries. Variability in the topography of the aquifer boundaries is one case where 3D analysis is necessary. In this work, density-dependent flow processes caused by 3D aquifer geometry are studied numerically and specifically, considering a lateral slope of the aquifer boundaries. Sub-horizontal circulation cells are formed in the saltwater entering the aquifer. The penetration of the saltwater can be quantified by a dimensionless buoyancy number that measures the lateral slope of the aquifer relative to freshwater flux. The penetration of the seawater intrusion wedge is controlled more by this slope than by the aquifer thickness and dispersivity. Thus, the slope must be taken into account in order to accurately evaluate seawater intrusion. ?? 2007 Elsevier B.V. All rights reserved.

  2. Hydrogeological study of the aquifer system of the northern Sahara in the Algero-Tunisian border: A case study of Oued Souf region

    NASA Astrophysics Data System (ADS)

    Halassa, Younes; Zeddouri, Aziez; Mouhamadou, Ould Babasy; Kechiched, Rabah; Benhamida, Abdeldjebbar Slimane

    2018-05-01

    The aquifer system in The Algero-Tunisian border and Chotts region is mainly composed of two aquifers: The first is the Complex Terminal (CT) and the second is the Intercalary aquifer (CI). This study aims the identification and spatial evolution of factors that controlling the water quality in the Complex Terminal aquifer (CT) in the Chotts region (Oued Souf region - Southeastern of Algeria). The concentration of major elements, temperature, pH and salinity were monitored during 2015 in 34 wells from the CT aquifer. The geological, geophysical, hydrogeological and hydrochemical methods were applied in order to carried out a model for the investigated aquifer system and to characterize the hydrogeological and the geochemical behavior, as well as the geometrical and the lithological configuration. Multivariate statistical analyses such as Principal Component Analysis (PCA) were also used for the treatment of several data. Results show that the salinity follows the same regional distribution of Chloride, Sodium, Magnesium, Sulfate and Calcium. Note that the salinity shows low contents in the upstream part of investigated region suggesting restricted dissolution of salts. Hydro-chemical study and saturation indexes highlight the dominance of the dissolution and the precipitation of calcite, dolomite, anhydrite, gypsum and halite. The PCA analysis indicates that Na+, Cl-, Ca2+, Mg2+, SO42- and K+ variables that influence the water mineralization.

  3. Value of information analysis for groundwater quality monitoring network design Case study: Eocene Aquifer, Palestine

    NASA Astrophysics Data System (ADS)

    Khader, A.; McKee, M.

    2010-12-01

    Value of information (VOI) analysis evaluates the benefit of collecting additional information to reduce or eliminate uncertainty in a specific decision-making context. It makes explicit any expected potential losses from errors in decision making due to uncertainty and identifies the “best” information collection strategy as one that leads to the greatest expected net benefit to the decision-maker. This study investigates the willingness to pay for groundwater quality monitoring in the Eocene Aquifer, Palestine, which is an unconfined aquifer located in the northern part of the West Bank. The aquifer is being used by 128,000 Palestinians to fulfill domestic and agricultural demands. The study takes into account the consequences of pollution and the options the decision maker might face. Since nitrate is the major pollutant in the aquifer, the consequences of nitrate pollution were analyzed, which mainly consists of the possibility of methemoglobinemia (blue baby syndrome). In this case, the value of monitoring was compared to the costs of treating for methemoglobinemia or the costs of other options like water treatment, using bottled water or importing water from outside the aquifer. And finally, an optimal monitoring network that takes into account the uncertainties in recharge (climate), aquifer properties (hydraulic conductivity), pollutant chemical reaction (decay factor), and the value of monitoring is designed by utilizing a sparse Bayesian modeling algorithm called a relevance vector machine.

  4. A closed form slug test theory for high permeability aquifers.

    PubMed

    Ostendorf, David W; DeGroot, Don J; Dunaj, Philip J; Jakubowski, Joseph

    2005-01-01

    We incorporate a linear estimate of casing friction into the analytical slug test theory of Springer and Gelhar (1991) for high permeability aquifers. The modified theory elucidates the influence of inertia and casing friction on consistent, closed form equations for the free surface, pressure, and velocity fluctuations for overdamped and underdamped conditions. A consistent, but small, correction for kinetic energy is included as well. A characteristic velocity linearizes the turbulent casing shear stress so that an analytical solution for attenuated, phase shifted pressure fluctuations fits a single parameter (damping frequency) to transducer data from any depth in the casing. Underdamped slug tests of 0.3, 0.6, and 1 m amplitudes at five transducer depths in a 5.1 cm diameter PVC well 21 m deep in the Plymouth-Carver Aquifer yield a consistent hydraulic conductivity of 1.5 x 10(-3) m/s. The Springer and Gelhar (1991) model underestimates the hydraulic conductivity for these tests by as much as 25% by improperly ascribing smooth turbulent casing friction to the aquifer. The match point normalization of Butler (1998) agrees with our fitted hydraulic conductivity, however, when friction is included in the damping frequency. Zurbuchen et al. (2002) use a numerical model to establish a similar sensitivity of hydraulic conductivity to nonlinear casing friction.

  5. Southwest principal aquifers regional ground-water quality assessment

    USGS Publications Warehouse

    Anning, D.W.; Thiros, Susan A.; Bexfield, L.M.; McKinney, T.S.; Green, J.M.

    2009-01-01

    The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey is conducting a regional analysis of water quality in the principal aquifers in the southwestern United States. The Southwest Principal Aquifers (SWPA) study is building a better understanding of the susceptibility and vulnerability of basin-fill aquifers in the region to ground-water contamination by synthesizing the baseline knowledge of ground-water quality conditions in 15 basins previously studied by the NAWQA Program. The improved understanding of aquifer susceptibility and vulnerability to contamination is assisting in the development of tools that water managers can use to assess and protect the quality of ground-water resources. This fact sheet provides an overview of the basin-fill aquifers in the southwestern United States and description of the completed and planned regional analyses of ground-water quality being performed by the SWPA study.

  6. Microbial Stimulation and Succession following a Test Well Injection Simulating CO₂ Leakage into a Shallow Newark Basin Aquifer

    PubMed Central

    O’Mullan, Gregory; Dueker, M. Elias; Clauson, Kale; Yang, Qiang; Umemoto, Kelsey; Zakharova, Natalia; Matter, Juerg; Stute, Martin; Takahashi, Taro; Goldberg, David

    2015-01-01

    In addition to efforts aimed at reducing anthropogenic production of greenhouse gases, geological storage of CO2 is being explored as a strategy to reduce atmospheric greenhouse gas emission and mitigate climate change. Previous studies of the deep subsurface in North America have not fully considered the potential negative effects of CO2 leakage into shallow drinking water aquifers, especially from a microbiological perspective. A test well in the Newark Rift Basin was utilized in two field experiments to investigate patterns of microbial succession following injection of CO2-saturated water into an isolated aquifer interval, simulating a CO2 leakage scenario. A decrease in pH following injection of CO2 saturated aquifer water was accompanied by mobilization of trace elements (e.g. Fe and Mn), and increased bacterial cell concentrations in the recovered water. 16S ribosomal RNA gene sequence libraries from samples collected before and after the test well injection were compared to link variability in geochemistry to changes in aquifer microbiology. Significant changes in microbial composition, compared to background conditions, were found following the test well injections, including a decrease in Proteobacteria, and an increased presence of Firmicutes, Verrucomicrobia and microbial taxa often noted to be associated with iron and sulfate reduction. The concurrence of increased microbial cell concentrations and rapid microbial community succession indicate significant changes in aquifer microbial communities immediately following the experimental CO2 leakage event. Samples collected one year post-injection were similar in cell number to the original background condition and community composition, although not identical, began to revert toward the pre-injection condition, indicating microbial resilience following a leakage disturbance. This study provides a first glimpse into the in situ successional response of microbial communities to CO2 leakage after subsurface injection in the Newark Basin and the potential microbiological impact of CO2 leakage on drinking water resources. PMID:25635675

  7. Slugtests in fractured aquifers - advantages and caveats

    NASA Astrophysics Data System (ADS)

    Sauter, Martin

    2017-04-01

    The hydraulic characterisation of fractured aquifers is a challenge due to the large contrast between conductive fractures and a relative low conductive rock matrix. Depending on the type of problem, spanning from water resources issues at catchment scale to contaminant transport at local, borehole scale, different methodological approaches are required. The employment of slugtests as a characterisation method has a major advantage above classical pumping tests since they provide information also for the lower end of the permeability spectrum and are less logistically demanding. However, the volume of investigation of slugtests is generally small and limited to the immediate borehole area. The application of slug tests to fractured systems was investigated by Barker and Black (1983); Dougherty and Babu (1984) and Karasaki et al. (1988). Barker and Black (1983) pointed out the non-uniqueness of type curves with re¬spect to determining reservoir parameters, apart from hydraulic conductivity and sto¬rage coefficients. The unknowns in¬clude fissure densities, apertures and the hy¬draulic parameters of the rock matrix. They found that the Cooper method syste¬matically overestimates aquifer transmis-sivities by a factor of up to three. This figure however applies to a fairly homogeneously fissured aquifer such as the English Chalk. Dougherty and Babu (1984) examined in detail the effects of partial penetration, dif¬ferent skin factors and mass exchange coef-ficients in a double porosity system. They did however not present any parameter estimation solu¬tion. Karasaki et al. (1988) developed type curves for heterogeneous aquifer systems and came to the conclusion that "slug tests suffer problems of non-uniqueness to a greater ex¬tent than other well tests". In this paper, this aspect of non-uniqueness is addressed in detail, based on slugtest data in a fractured and karstified aquifer from the Swabian Alb in the SW of Germany, explanations and models of interpretation are provided and assessed with respect to their relative importance.

  8. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    USGS Publications Warehouse

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  9. Source of water to Lithia Springs in Hillsborough County, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hickey, J.J.; Coates, M.J.

    1993-03-01

    The source of water to Lithia Springs adjacent to the Alafia River in Hillsborough County, Florida has traditionally been hypothesized to be from the Upper Floridan aquifer. As a result, potential impacts from an adjacent public supply well field has been of interest since the well field began production in July, 1988. The discharge from Lithia Springs since March, 1984 has averaged about 3,600,000 cubic feet per day. Pumpage from the adjacent well field since July, 1988 has averaged about 2,500,000 cubic feet per day. A comparison between mean daily pumpage from the well field and mean daily discharge frommore » the springs showed no apparent association indicating that the Floridan aquifer may not be the source for the springs. Lithologic data suggested that the Upper Floridan aquifer was confined with no direct connection to the springs. This confining unit hypothesis was tested and accepted by pumping two wells close to the springs. The test consisted of pumping both wells for about 13 days at a combined rate that was about 40% of the average daily well field pumpage. No discernable test caused effects were observed on the springs or in an adjacent 115-foot deep well open to carbonate rock. Because of this, it was concluded that the Upper Floridan aquifer was not the source of water to Lithia Springs. Interpretation of available data suggested that the source of water to Lithia Springs was from the intermediate aquifer system located within solution riddled Early Miocene carbonate rocks of the lower Hawthorn Formation with maybe an important aquifer contribution from the Alafia River.« less

  10. AUTOMATED WATER LEVEL MEASUREMENTS IN SMALL-DIAMETER AQUIFER TUBES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PETERSEN SW; EDRINGTON RS; MAHOOD RO

    2011-01-14

    Groundwater contaminated with hexavalent chromium, strontium-90, and uranium discharges into the Columbia River along approximately 16 km (10 mi) of the shoreline. Various treatment systems have and will continue to be implemented to eliminate the impact of Hanford Site contamination to the river. To optimize the various remediation strategies, it is important to understand interactions between groundwater and the surface water of the Columbia River. An automated system to record water levels in aquifer sampling tubes installed in the hyporheic zone was designed and tested to (1) gain a more complete understanding of groundwater/river water interactions based on gaining andmore » losing conditions ofthe Columbia River, (2) record and interpret data for consistent and defensible groundwater/surface water conceptual models that may be used to better predict subsurface contaminant fate and transport, and (3) evaluate the hydrodynamic influence of extraction wells in an expanded pump-and-treat system to optimize the treatment system. A system to measure water levels in small-diameter aquifer tubes was designed and tested in the laboratory and field. The system was configured to allow manual measurements to periodically calibrate the instrument and to permit aquifer tube sampling without removing the transducer tube. Manual measurements were collected with an e-tape designed and fabricated especially for this test. Results indicate that the transducer system accurately records groundwater levels in aquifer tubes. These data are being used to refine the conceptual and numeric models to better understand interactions in the hyporheic zone of the Columbia River and the adjacent river water and groundwater, and changes in hydrochemistry relative to groundwater flux as river water recharges the aquifer and then drains back out in response to changes in the river level.« less

  11. Longitudinal hydraulic analysis of river‐aquifer exchanges

    USGS Publications Warehouse

    Konrad, C.P.

    2006-01-01

    A longitudinal analysis of transient flow between a river and an underlying aquifer is developed to calculate flow rates between the river and the aquifer and the location of groundwater seepage into the river as it changes over time. Two flow domains are defined in the analysis: an upstream domain of fluvial recharge, where water flows vertically from the river into the unsaturated portion of the aquifer and horizontally in saturated parts of the aquifer, and a downstream domain of groundwater seepage to the river, where groundwater flows parallel to the underlying impermeable base. The river does not necessarily penetrate completely through the aquifer. A one‐dimensional, unsteady flow equation is derived from mass conservation, Darcy's law, and the geometry of the river‐aquifer system to calculate the water table position and the groundwater seepage rate into the river. Models based on numerical and analytical solutions of the flow equation were applied to a reach of the Methow River in north central Washington. The calibrated models simulated groundwater seepage with a root‐mean‐square error less than 5% of the mean groundwater seepage rates for three low‐flow evaluation periods. The analytical model provides a theoretical basis for a nonlinear exponential base flow recession generated by a draining aquifer, but not an explicit functional form for the recession. Unlike cross‐sectional approaches, the longitudinal approach allows the analysis of the length and location of groundwater seepage to a river, which have important ecological implications in many rivers. In the numerical simulations, the length of the groundwater seepage varied seasonally by about 4 km and the upstream boundary of groundwater seepage was within 689 m of its location at a stream gage on 9 September 2001 and within 91 m of its location on 6 October 2002. To demonstrate its utility in ecological applications, the numerical model was used to calculate differences in length of groundwater seepage to the Methow River under an early runoff scenario and the timing of those differences with respect to life stages of chinook salmon.

  12. Digital computer simulation model of the Englishtown aquifer in the northern coastal plain of New Jersey

    USGS Publications Warehouse

    Nichols, W.D.

    1977-01-01

    Continued decline of water levels in the Englishtown aquifer, in New Jersey, has caused considerable concern regarding the ability of the aquifer to meet future yield demands. A detailed study of the capability of the aquifer to yield water entailed the use of a digital computer simulation model to evaluate aquifer and confining layer coefficients and to test alternative concepts of the hydrodynamics of the flow system. The modeled area includes about 750 square miles of the northern Coastal Plain of New Jersey and encompasses all the major centers of pumping from the Englishtown aquifer. The simulation model was calibrated by matching computed declines with historical water-level declines over the 12-year period, 1959-70. The volume of transient and steady leakage into the Englishtown aquifer from and through the adjacent confining layers equaled more than 90 percent of the total volume of water withdrawn from the aquifer between 1959 and 1970. The analytical estimate of transient leakage indicates that about 60 percent of the water withdrawn from the Englishtown between 1959 and 1970 was replaced by water released from storage in the adjacent confining beds. An additional 34 percent of the withdrawal over this time period was supported by steady leakage through the overlying confining bed from the Mount Laurel aquifer. Of the more than 30 billion gallons withdrawn from the aquifer over the 12-year period, about 2 billion gallons were obtained from storage in the aquifer. The values of aquifer and confining-layer coefficients used in the model are nearly the same as the average values obtained from field and laboratory data. (Woodard-USGS)

  13. A half-decade of field research on the Greenland firn aquifers - major advances and looming questions.

    NASA Astrophysics Data System (ADS)

    Koenig, L.; Forster, R. R.; Miller, O. L.; Solomon, D. K.; Miège, C.; Schmerr, N. C.; Montgomery, L. N.; Legchenko, A.

    2017-12-01

    In 2011, researchers first drilled into an unknown firn aquifer in Southeast, Greenland. Over the past half-decade our team has conducted field work instrumenting, modeling and remote sensing the aquifer and surrounding snow/firn/ice to get a more complete picture of the system including formation conditions, controlling mechanisms, spatial and temporal change, and connections with the larger ice sheet system. This work summarizes recently published work on the firn aquifer providing our best estimates on the spatial extents, depths and water volumes for the purpose of estimating available water that could reach the en- or subglacial hydrologic network. To do this we reconcile and explain the differences in water volume estimates from three methods, ice core measurements, magnetic resonance and dilution tests. We present measurements of the hydrologic conductivities within a Greenland firn aquifer from two methods, at multiple locations showing that water can flow more freely in ice sheet aquifers than mountain glaciers and attribute this difference to the longer duration of water retained in ice sheet aquifers. While connections of the aquifer water to the glacier bed have been hypothesized and are supported by surface velocity measurements, we still lack direct observations. We show the surface velocity for most aquifer regions ranges from a few meters to 300 m a year with substantial spatial and temporal variability. Given possible aquifer water input scenarios, derived from our field measurements, to the glacier bed, we compare and contrast the seasonal surface velocities and variability of surface velocity for different outlet glaciers that are both connected and not connected to firn aquifers.

  14. Variations in hydraulic conductivity with scale of measurement during aquifer tests in heterogeneous, porous carbonate rocks

    NASA Astrophysics Data System (ADS)

    Schulze-Makuch, Dirk; Cherkauer, Douglas S.

    Previous studies have shown that hydraulic conductivity of an aquifer seems to increase as the portion of the aquifer tested increases. To date, such studies have all relied on different methods to determine hydraulic conductivity at each scale of interest, which raises the possibility that the observed increase in hydraulic conductivity is due to the measurement method, not to the scale. This study analyzes hydraulic conductivity with respect to scale during individual aquifer tests in porous, heterogeneous carbonate rocks in southeastern Wisconsin, USA. Results from this study indicate that hydraulic conductivity generally increases during an individual test as the volume of aquifer impacted increases, and the rate of this increase is the same as the rate of increase determined by using different measurement methods. Thus, scale dependence of hydraulic conductivity during single tests does not depend on the method of measurement. This conclusion is supported by 22 of 26 aquifer tests conducted in porous-flow-dominated carbonate units within the aquifer. Instead, scale dependency is probably caused by heterogeneities within the aquifer, a conclusion supported by digital simulation. All of the observed types of hydraulic-conductivity variations with scale during individual aquifer tests can be explained by a conceptual model of a simple heterogeneous aquifer composed of high-conductivity zones within a low-conductivity matrix. Résumé Certaines études ont montré que la conductivité hydraulique d'un aquifère semble augmenter en même temps que la partie testée de l'aquifère s'étend. Jusqu'à présent, ces études ont toutes reposé sur des méthodes de détermination de la conductivité hydraulique différentes pour chaque niveau d'échelle, ce qui a conduit à penser que l'augmentation observée de la conductivité hydraulique pouvait être due aux méthodes de mesure et non à l'effet d'échelle. Cette étude analyse la conductivité hydraulique par rapport au niveau d'échelle au cours d'essais de nappe individuels, dans des roches carbonatées poreuses, hétérogènes du sud-est du Wisconsin (Etats-Unis). Les résultats obtenus indiquent que la conductivité hydraulique augmente en général au cours d'un essai individuel en même temps que le volume d'aquifère concerné augmente, et que le taux d'augmentation est le même que celui déterminé en utilisant différentes méthodes de mesures. Ainsi, le fait que la conductivité hydraulique dépende de l'échelle d'observation au cours d'essais uniques ne résulte pas de la méthode de mesure. Cette conclusion est confirmée par 22 essais de nappe sur 26 entrepris dans des unités carbonatées àécoulement poreux dominant dans l'aquifère. En revanche, cette dépendance du niveau d'échelle est probablement due aux hétérogénéités existant dans l'aquifère, conclusion confortée par une simulation. Tous les types de variations de conductivité hydraulique en fonction de l'échelle au cours d'essais de nappe peuvent être expliqués par un modèle conceptuel d'aquifère hétérogène simple constitué par des zones à forte conductivitéà l'intérieur d'une matrice à faible conductivité. Resumen Estudios previos han mostrado que la conductividad hidráulica (K) de un acuífero parece crecer con el volumen ensayado. Hasta ahora, estos estudios se han basado en la utilización de métodos distintos para la determinación de la conductividad hidráulica a cada escala de interés, lo que hace pensar en la posibilidad de que este aumento observado sea debido a la variación en el método de medida y no al cambio de escala. Este estudio analiza el valor de K en función de la escala a partir de ensayos individuales en rocas carbonatadas heterogéneas y porosas al sudeste de Wisconsin, EEUU. Los resultados de este estudio indican que la K obtenida en ensayos individuales crece generalmente al aumentar el volumen de acuífero implicado en el ensayo, y que la tasa de crecimiento es la misma que se determinaría usando diferentes métodos. Por tanto, la dependencia de la conductividad hidráulica con la escala en ensayos aislados no depende del método de medida. Esta conclusión está refrendada por 22 de los 26 ensayos llevados a cabo en las unidades carbonatadas más porosas del acuífero. Por el contrario, la dependencia con la escala está causada probablemente por las heterogeneidades en el propio acuífero, lo que se corrobora con simulaciones digitales. Todos los tipos de variaciones de K con la escala observados para los ensayos individuales se pueden explicar mediante un modelo conceptual simple que supone un acuífero heterogéneo compuesto por zonas de alta conductividad embebidas en una matriz poco conductiva.

  15. Hydrogeochemical Analysis of an Overexploited Aquifer In Bangladesh Toward Managed Aquifer Recharge Project Implementation

    NASA Astrophysics Data System (ADS)

    Rahman, M. A.; Wiegand, B. A.; Pervin, M.; Sauter, M.

    2012-12-01

    In most parts of the upper Dupitila aquifer (Dhaka City, Bangladesh) the average groundwater depletion reaches 2-3 m/year due to increasing water demands of the growing population. To counteract overexploitation of the aquifer, a more sustainable water management is required. The analysis of the local water resources system suggests that Managed Aquifer Recharge (MAR) would help to restore groundwater resources to strengthen water supply of Dhaka City, e.g., by using collected urban monsoon runoff and excess surface water from rivers. To assess possible effects of surface water or rainwater injection on groundwater quality, a comprehensive hydrogeochemical survey of the Dupitila aquifer is required. This paper presents hydrogeochemical data to document the current status of groundwater quality and to evaluate potential groundwater pollution by mobilization of hazardous chemicals as a result of changes in the hydrochemical equilibria. We performed a comprehensive review of available secondary data sources and will present new results from hydrochemical and Sr isotope investigations of water samples that were conducted within this study. Currently, groundwater quality in the upper Dupitila aquifer is characterized by variations in the electrical conductivity in the range of 200 to 1100 μS/cm, which may indicate some anthropogenic contamination by leakage from waste disposal including the sewage network and from surface water infiltration into the groundwater aquifer. Dissolved oxygen concentrations range from 1.0 to 4.9 mg/L (average 2.5 mg/L) in the upper Dupitila aquifer, while the lower Dupilita aquifer shows dissolved oxygen concentrations in the range 0 to 0.7 mg/L. Concentrations of major ions show some variation primarily due to a sedimentologically/mineralogically heterogeneous aquifer composition (sand, gravel, clay horizons), but may also be affected by anthropogenic processes. The groundwater composition is predominated by Ca-Mg-HCO3 and saturation values with respect to calcite are between -0.1 and -2.0. Trace elements are generally below WHO and Bangladesh standard values, except for higher iron and manganese concentrations in some wells. Groundwater from the Dupitila aquifer is not contaminated by arsenic, but mobilisation of arsenic from the aquifer sediments may occur when iron (III) oxides are dissolved in the storage zone. Based on the evaluation of hydrogeochemical data the major challenges and uncertainties of a MAR project implementation in Dhaka City will be discussed.

  16. Hydrogeology and water quality of the Leetown area, West Virginia

    USGS Publications Warehouse

    Kozar, Mark D.; McCoy, Kurt J.; Weary, David J.; Field, Malcolm S.; Pierce, Herbert A.; Schill, William Bane; Young, John A.

    2008-01-01

    The U.S. Geological Survey’s Leetown Science Center and the co-located U.S. Department of Agriculture’s National Center for Cool and Cold Water Aquaculture both depend on large volumes of cold clean ground water to support research operations at their facilities. Currently, ground-water demands are provided by three springs and two standby production wells used to augment supplies during periods of low spring flow. Future expansion of research operations at the Leetown Science Center is dependent on assessing the availability and quality of water to the facilities and in locating prospective sites for additional wells to augment existing water supplies. The hydrogeology of the Leetown area, West Virginia, is a structurally complex karst aquifer. Although the aquifer is a karst system, it is not typical of most highly cavernous karst systems, but is dominated by broad areas of fractured rock drained by a relatively small number of solution conduits. Characterization of the aquifer by use of fluorometric tracer tests, a common approach in most karst terranes, therefore only partly defines the hydrogeologic setting of the area. In order to fully assess the hydrogeology and water quality in the vicinity of Leetown, a multi-disciplinary approach that included both fractured rock and karst research components was needed. The U.S. Geological Survey developed this multi-disciplinary research effort to include geologic, hydrologic, geophysical, geographic, water-quality, and microbiological investigations in order to fully characterize the hydrogeology and water quality of the Leetown area, West Virginia. Detailed geologic and karst mapping provided the framework on which hydrologic investigations were based. Fracture trace and lineament analysis helped locate potential water-bearing fractures and guided installation of monitoring wells. Monitoring wells were drilled for borehole geophysical surveys, water-quality sampling, water-level measurements, and aquifer tests to characterize the quality of water and the hydraulic properties of the aquifer. Surface geophysical surveys provided a 3-dimensional view of bedrock resistivity in order to assess geologic and lithologic controls on ground-water flow. Borehole geophysical surveys were conducted in monitoring wells to assess the storage and movement of water in subsurface fractures. Numerous single-well, multi-well, and straddle packer aquifer tests and step-drawdown tests were conducted to define the hydraulic properties of the aquifer and to assess the role of bedrock fractures and solution conduits in the flow of ground water. Water samples collected from wells and springs were analyzed to assess the current quality of ground water and provide a baseline for future assessment. Microbiological sampling of wells for indicator bacteria and human and animal DNA provided an analysis of agricultural and suburban development impacts on ground-water quality. Light detection and ranging (LiDAR) data were analyzed to develop digital elevation models (DEMs) for assessing sinkhole distribution, to provide elevation data for development of a ground-water flow model, and to assess the distribution of major fractures and faults in the Leetown area. The flow of ground water in the study area is controlled by lithology and geologic structure. Bedrock, especially low permeability units such as the shale Martinsburg Formation and the Conococheague Limestone, act as barriers to water flowing down gradient and across bedding. This retardation of cross-strike flow is especially pronounced in the Leetown area, where bedding typically dips at steep angles. Highly permeable fault and fracture zones that disrupt the rocks in cross-strike directions provide avenues through which ground water can flow laterally across or through strata of low primary permeability. Significant strike parallel thrust faults and cross-strike faults typically coincide with larger solution conduits and act as drains for the more pervasive network of interconnected diffuse fractures. Results of borehole geophysical surveys indicate that although numerous fractures may intersect a borehole, only one or two of the fractures typically transmit most of the water to a well. The diffuse-flow dominated network of fractures that provides the majority of storage occupies only a small proportion of the total aquifer volume but constitutes the majority of porosity within the aquifer. Solution conduits, while occupying a relatively small volume of the overall aquifer, are especially important because they serve as primary drains for the ground-water flow system. Surface resistivity maps and cross-sectionsshow anomalous areas of low resistivities coincident with the prevailing geologic strike at N. 20º E., with major cross-strike faults, and with major springs in the region. Transmissivity derived from straddle packer tests was highly variable, and ranged over three orders of magnitude (1.8 x 10-6 to 5.9 x 10-3 ft2/d) in diffuse-flow fractures. A similar large variability in transmissivity was documented by single- and multi-well aquifer tests conducted in conduit-flow dominated portions of the aquifer (2.0 x 103 to 1.4 x 104 ft2/d) in lowland areas immediately adjacent to the Leetown Science Center. A stream-gaging station installed on Hopewell Run near the point where the stream exits the Leetown watershed indicates average daily streamflow for the Hopewell Run of approximately 11.2 ft3/s, and ranged from a minimum of 1.80 ft3/s on September 28, 2005, to a maximum of 73.0 ft3/s on December 11, 2003. Base-flow (ground-water) discharge surveys identified numerous small seeps adjacent to streams in the area. Hydrographs of the stage of Balch Spring show rapid response to individual storms. Strong correlation of the flow of Hopewell Run and Balch Spring indicates the nearby losing stream reach is partly responsible for higher fluctuations in the stage of Balch Spring. A water budget for the study period (2003-2005), based on measured precipitation and hydrograph analyses, is expressed as Precipitation (38.60 in/yr) = Surface Runoff (1.36 in/yr) + Ground-Water Discharge (17.73 in/yr) + Evapotranspiration (24.23 in/yr) – Change in storage (4.72 in/yr). Flow of ground water through the epikarst, a shallow zone of intensely weathered rock and regolith, can be rapid (on the order of days or weeks) as flow is concentrated in solution conduits. Flow within the intermediate and deeper zones is typically much slower. Eight dye-tracer tests conducted in the Leetown area found ground-water flow patterns to be divergent, with velocities ranging from about 12.5 to 610 ft/day and a median velocity of 50 ft/day. Estimates of ground-water age in carbonate rocks in the region are on the order of 15 years in the shallower portions of the aquifer to 50 years or older for deeper portions of the aquifer. Shallow springs can have a significant component of fairly young water ( Ground-water samples collected from 16 sites (12 wells and 4 springs) in the Leetown area were analyzed for more than 340 constituents. Only turbidity, indicator bacteria, and radon were typically present in concentrations exceeding U.S. Environmental Protection Agency (USEPA) drinking-water or aquatic life standards.

  17. What Can We Learn About Karst Aquifer Heterogeneity From Pumping Tests

    NASA Astrophysics Data System (ADS)

    Marechal, J. C.; Dewandel, B.; Ladouche, B.; Fleury, P.

    2016-12-01

    Due to the complexity and duality of flows, well-test interpretation into karst systems constitutes a challenging task for hydrogeologists. This is especially true when the pumping well intersects karst heterogeneities such as the conduit network. The method of diagnostic plots, widely used in oil industry, can be applied to karst hydrogeology. In this paper, the classical response of a well-test into a karst conduit is described on a log-log drawdown derivative curve. It allows identifying successive flow regimes corresponding to the contribution of various karst aquifer subsystems (fractured matrix, karst conduit, main karst drainage network) to the pumped well. In heterogeneous karst systems, the log-log diagnostic plot of drawdown and its derivative in the pumping well can help identifying departures in flow-geometry from the classical homogeneous radial case. Classically, the diagnostic plot can be divided into several portions with: (a) early data used for identifying the karst conduit storage; (b) intermediate data for identifying the type of aquifer model that should be used (e.g. double porosity, anisotropy...); and (c) late data for identifying the possible boundaries. This is illustrated on three examples from Mediterranean karsts in southern France. A one-month duratio pumping test on a well intersecting the main karst drainage network of the Cent-Fonts karst system shows (i) a preliminary contribution of the karst conduit storage capacity followed by (ii) linear flows into the fractured matrix. A pumping test on a well intersecting a small karst conduit of the Corbières karst system shows the existence of (i) bi-linear flow within both the karst conduit and the fractured matrix at early times, followed by (ii) radial flows within the fractured matrix and (iii) finally the contribution of a major karst cavity. A two-months duration pumping test on a deep confined karst aquifer under low permeability rocks into the Gardanne basin shows the existence of no-flow boundary conditions due to the basin extension. The use of diagnostic plots allows identifying the various flow regimes during pumping tests, corresponding to the response of the individual karst aquifer subsystems. This is helpful for improving the understanding of the structure of the karst aquifer and flow exchanges between subsystems.

  18. Interpretation of Borehole Geophysical Logs, Aquifer-Isolation Tests, and Water-Quality Data for Sites 1, 3, and 5 at the Willow Grove Naval Air Station/Joint Reserve Base, Horsham Township, Montgomery County, Pennsylvania: 2005

    USGS Publications Warehouse

    Sloto, Ronald A.

    2007-01-01

    Borehole geophysical logging, heatpulse-flowmeter measurements, borehole television surveys, and aquifer-isolation tests were conducted in 2005 at the Willow Grove Naval Air Station/Joint Reserve Base (NAS/JRB) in Horsham Township, Montgomery County, Pa. This study was done by the U.S. Geological Survey (USGS) in cooperation with the U.S. Navy in support of hydrogeological investigations to address ground-water contamination. Data collected for this study are valuable for understanding ground-water flow in the Stockton Formation at the local and regional scale. The Willow Grove NAS/JRB is underlain by the Stockton Formation, which consists of sedimentary rocks of Triassic age. The rocks of the Stockton Formation form a complex, heterogeneous aquifer with partially connected zones of high permeability. Borehole geophysical logs, heatpulse-flowmeter measurements, and borehole television surveys made in seven boreholes ranging from 70 to 350 ft deep were used to identify potential water-producing fractures and fracture zones and to select intervals for aquifer-isolation tests. An upward vertical hydraulic gradient was measured in one borehole, a downward vertical hydraulic gradient was measured in four boreholes, both an upward and a downward vertical hydraulic gradient were measured in one borehole, and no flow was measurable in one borehole. The aquifer-isolation tests isolated 30 discrete fractures in the seven boreholes for collection of depth-discrete hydraulic and water-quality data. Of the 30 fractures identified as potentially water producing, 26 fractures (87 percent) produced more than 1 gallon per minute of water. The specific capacity of the isolated intervals producing more than 1 gallon per minute ranged from 0.02 to 5.2 gallons per minute per foot. There was no relation between specific capacity and depth of the fracture. Samples for analysis for volatile organic compounds were collected from each isolated zone. Tetrachloroethylene (PCE) was the most prevalent compound at Site 1; concentrations were as great as 62 ?g/L (micrograms per liter). 1,1-dichloroethane was the most prevalent compound at Site 3; concentrations were as great as 9.3 ?g/L. Toluene was the most prevalent compound at Site 5; concentrations were as great as 77 ?g/L. For five out of the six wells (83 percent) sampled for field determinations of water-quality constituents, the interval with the lowest dissolved oxygen concentration had the highest total VOC concentration.

  19. Effects of hydrogeological and anthropogenic factors on the distribution of CVOCs in eogenetic karst aquifers

    NASA Astrophysics Data System (ADS)

    Torres Torres, N. I.; Padilla, I. Y.; Rivera, V. L.

    2016-12-01

    Eogenetic kart aquifers are characterized by well-developed conduit networks within a rock matrix having significant primary porosity and permeability. These aquifers are highly productive and serve as important source of water for multiple uses. As a consequence, eogenetic karst regions are attractive for industrial, urban, and agricultural development that can serve as contaminations sources for the aquifers. It is hypothesized that the distribution of contaminants in these aquifers are influenced by combined characteristics of source and hydrogeological features. This research assesses the spatio-temporal distribution of chlorinated volatile organic compounds (CVOCs) in the eogenetic karst aquifers of northern Puerto Rico (NPR) and studies the correlation between hydrogeological and anthropogenic variables and groundwater contamination using Geographic Information System and statistical methods. CVOCs, which are used as dry cleaning and industrial solvents, degreasers and paint or spot removers, are among the most commonly found groundwater contaminants in the world. The NPR karst aquifers have been heavily impacted by land development and groundwater contamination, particularly CVOCs, with Trichloroethylene, Tetrachloroethylene, and Carbon Tetrachloride among the most detected contaminants. The analysis shows that 62% of the samples and 78% of the sites sampled have presence of one or more CVOC, and that their concentrations vary with time. Detection and concentrations of certain CVOCs are associated with some sources of known contamination. Significant presence of CVOCs is also found near developed and agricultural land uses. The shallow aquifer shows greater presence of CVOCs (66%) than the confined aquifer (16%), with most detections occurring in areas of low and medium sinkholes coverage and medium hydraulic conductivities. Multivariate statistical analysis indicates that, indeed, the distribution of CVOCs in the karsts aquifers of NPR is influenced by a combination of contaminant source and hydrogeological factors. These factors, which facilitate the entry of contaminants into the system, and promote their transport and storage, have resulted in extensive spatial and temporal contamination of eogenetic karst groundwater systems, such as those found in northern Puerto Rico.

  20. Applicability of aquifer impact models to support decisions at CO2 sequestration sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keating, Elizabeth; Bacon, Diana; Carroll, Susan

    2016-09-01

    The National Risk Assessment Partnership has developed a suite of tools to assess and manage risk at CO2 sequestration sites (www.netldoe.gov/nrap). This capability includes polynomial or look-up table based reduced-order models (ROMs) that predict the impact of CO2 and brine leaks on overlying aquifers. The development of these computationally-efficient models and the underlying reactive transport simulations they emulate has been documented elsewhere (Carroll et al., 2014, Dai et al., 2014, Keating et al., 2015). The ROMs reproduce the ensemble behavior of large numbers of simulations and are well-suited to applications that consider a large number of scenarios to understand parametermore » sensitivity and uncertainty on the risk of CO2 leakage to groundwater quality. In this paper, we seek to demonstrate applicability of ROM-based ensemble analysis by considering what types of decisions and aquifer types would benefit from the ROM analysis. We present four hypothetical four examples where applying ROMs, in ensemble mode, could support decisions in the early stages in a geologic CO2 sequestration project. These decisions pertain to site selection, site characterization, monitoring network evaluation, and health impacts. In all cases, we consider potential brine/CO2 leak rates at the base of the aquifer to be uncertain. We show that derived probabilities provide information relevant to the decision at hand. Although the ROMs were developed using site-specific data from two aquifers (High Plains and Edwards), the models accept aquifer characteristics as variable inputs and so they may have more broad applicability. We conclude that pH and TDS predictions are the most transferable to other aquifers based on the analysis of the nine water quality metrics (pH, TDS, 4 trace metals, 3 organic compounds). Guidelines are presented for determining the aquifer types for which the ROMs should be applicable.« less

  1. Planning report for the Edwards-Trinity Regional Aquifer-System analysis in central Texas, southeast Oklahoma, and southwest Arkansas

    USGS Publications Warehouse

    Bush, Peter W.

    1986-01-01

    The Edwards-Trinity regional aquifer-system analysis project, begun in October 1985 and scheduled to be completed by October 1991, is one of a series of similar projects being conducted nationwide. The project is intended to define the hydrogeologic framework, and to describe the geochemistry and groundwater flow of the aquifer system in order to provide a better understanding of the system's long-term water-yielding potential. A multidisciplinary approach will be used in which computer-based digital simulation of flow in the system will be the principal method of hydrogeologic investigation.

  2. Generalized potentiometric surface of aquifers of Pleistocene age, Southern Louisiana, 1980

    USGS Publications Warehouse

    Martin, Angel; Whiteman, Charles D.

    1985-01-01

    A map of potentiometric surface defines generalized water levels for 1980 in the Pleistocene aquifers of southern Louisiana. The map was prepared as part of the Western Gulf Coast Regional Aquifer-System Analysis study. The Pleistocene deposits in southern Louisiana consist of alternating beds of sand, gravel, silt, and clay deposited under fluvial, deltaic, and near-short marine conditions. The aquifers are mainly under artesian conditions and the regional flow direction is primarily southward. Areally definable cones of depression result from heavy pumpage in the Baton Rouge, Lake Charles, and New Orleans metropolitan areas and in the rice irrigation area of southwestern Louisiana. Where water levels differ vertically within the aquifer, the lowest water levels in the vertical section were used because these levels represented the thickest and most heavily pumped unit in the aquifer. The map represents regional water levels in the Pleistocene aquifers, and is not intended to show localized variations near pumping centers. (USGS)

  3. Total Reducing Capacity in Aquifer Minerals and Sediments: Quantifying the Potential to Attenuate Cr(VI) in Groundwater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisman, S. Lara

    2015-07-20

    Hexavalent chromium, Cr(VI), is present in the environment as a byproduct of industrial processes. Due to its mobility and toxicity, it is crucial to attenuate or remove Cr(VI) from the environment. The objective of this investigation was to quantify potential natural attenuation, or reduction capacity, of reactive minerals and aquifer sediments. Samples of reduced-iron containing minerals such as ilmenite, as well as Puye Formation sediments representing a contaminated aquifer in New Mexico, were reacted with chromate. The change in Cr(VI) during the reaction was used to calculate reduction capacity. This study found that minerals that contain reduced iron, such asmore » ilmenite, have high reducing capacities. The data indicated that sample history may impact reduction capacity tests due to surface passivation. Further, this investigation identified areas for future research including: a) refining the relationships between iron content, magnetic susceptibility and reduction capacity, and b) long term kinetic testing using fresh aquifer sediments.« less

  4. Estimation of the groundwater resources of the bedrock aquifers at the Kettle Moraine Springs State Fish Hatchery, Sheboygan County, Wisconsin

    USGS Publications Warehouse

    Dunning, Charles; Feinstein, Daniel T.; Buchwald, Cheryl A.; Hunt, Randall J.; Haserodt, Megan J.

    2017-10-12

    Groundwater resources information was needed to understand regional aquifer systems and water available to wells and springs for rearing important Lake Michigan fish species at the Kettle Moraine Springs State Fish Hatchery in Sheboygan County, Wisconsin. As a basis for estimating the groundwater resources available, an existing groundwater-flow model was refined, and new groundwater-flow models were developed for the Kettle Moraine Springs State Fish Hatchery area using the U.S. Geological Survey (USGS) finite-difference code MODFLOW. This report describes the origin and construction of these groundwater-flow models and their use in testing conceptual models and simulating the hydrogeologic system.The study area is in the Eastern Ridges and Lowlands geographical province of Wisconsin, and the hatchery property is situated on the southeastern edge of the Kettle Moraine, a north-south trending topographic high of glacial origin. The bedrock units underlying the study area consist of Cambrian, Ordovician, and Silurian units of carbonate and siliciclastic lithology. In the Sheboygan County area, the sedimentary bedrock sequence reaches a thickness of as much as about 1,600 feet (ft).Two aquifer systems are present at the Kettle Moraine Springs State Fish Hatchery. A shallow system is made up of Silurian bedrock, consisting chiefly of dolomite, overlain by unconsolidated Quaternary-age glacial deposits. The glacial deposits of this aquifer system are the typical source of water to local springs, including the springs that have historically supplied the hatchery. The shallow aquifer system, therefore, consists of the unconsolidated glacial aquifer and the underlying bedrock Silurian aquifer. Most residential wells in the area draw from the Silurian aquifer. A deeper confined aquifer system is made up of Cambrian- and Ordovician-age bedrock units including sandstone formations. Because of its depth, very few wells are completed in the Cambrian-Ordovician aquifer system (COAS) near the Kettle Moraine Springs State Fish Hatchery.Three groundwater-flow models were used to estimate the water resources available to the hatchery from bedrock aquifers under selected scenarios of well placement and seasonal water requirements and subject to constraints on the effects of pumping on neighboring wells, local springs, and creeks. Model input data (recharge, water withdrawal, and boundary conditions) for these models were compiled from a number of data and information sources.The first model, named the “KMS model,” (KMS stands for Kettle Moraine Springs) is an inset model derived from a published USGS regional Lake Michigan Basin model and was constructed to simulate groundwater pumping from the semiconfined Silurian aquifer. The second model, named the “Pumping Test model,” was constructed to evaluate an aquifer pumping test conducted in the COAS as part of this project. The Pumping Test model was also used to simulate the local effects of 20 years of groundwater pumping from this deep bedrock aquifer for future hatchery operations. The third model, named the “LMB modified model,” is a version of the published Lake Michigan Basin (LMB) model that was modified with aquifer parameters refined in an area around the hatchery (approximately a 5-mile radius circle, corresponding to the area stressed by the aquifer pumping test). This LMB modified model was applied to evaluate regional effects of pumping from the confined COAS.The available Silurian aquifer groundwater resource was estimated using the KMS model with three scenarios—named “AllConstraints,” “Constraints2,” and “Constraints3”—that specified local water-level and flow constraints such as drawdown at nearby household wells, water levels inside pumping well boreholes, and flow in local streams and springs. Each scenario utilized the MODFLOW Groundwater Management Process (GWM) to select three locations from six candidate locations that provided the greatest combined flow while satisfying the constraints. The three constraint scenarios provided estimates of 430 gallons per minute (gal/min), 480 gal/min, and 520 gal/min pumping from three wells—AllConstraints, Constraints2, and Constraints3, respectively. The same three wells were selected for the scenarios that estimated 480 gal/min and 520 gal/min; the scenario that estimated 430 gal/min shared two of these same wells, but the third selected well was different.The available COAS groundwater resource was estimated by two scenarios with each conducted over a period of 20 years with the Pumping Test model and the LMB modified model. The Pumping Test model was used to simulate local effects of pumping, and the LMB modified model was used to simulate regional effects of pumping. The scenarios simulate a range of total and seasonal pumping rates potentially linked to site activities. Scenario 1 simulates two wells completed in the Cambrian-Ordovician aquifer system, each pumping for 8 months at 300 gal/min, followed by pumping for 4 months at 600 gal/min. The average yearly pumping rate of Scenario 1 is 800 gal/min. Scenario 2 simulates three wells completed in the Cambrian-Ordovician aquifer system pumping for 8 months at 200 gal/min, followed by pumping for 4 months at 500 gal/min. The average yearly pumping rate of Scenario 2 is 900 gal/min. The Pumping Test model simulations confirmed that drawdown in the boreholes of the pumping wells at the selected 2-well or 3-well rates will meet the desired condition that the pumping water level remains at least 100 ft above the highest Cambrian-Ordovician unit open to the well.The LMB modified model was used to evaluate the regional drawdown of the pumping from the confined COAS under the same 2-well and 3-well scenarios. At the nearest known existing COAS well, Campbellsport production well #4, the simulated drawdown for Scenario 1 after 20 years of cyclical pumping with two pumping wells averaging a total of 800 gal/min is 16.9 ft, whereas the simulated drawdown for Scenario 2 after 20 years of pumping with three pumping wells averaging a total of 900 gal/min is 19.0 ft. The total deep aquifer thickness at the Campbellsport location is on the order of 620 ft, meaning that the simulated drawdown for either scenario is about 3 percent of the confined aquifer thickness.The models developed as part of this project are archived in the project data release. The archive includes the model input and output files as well as MODFLOW source code and executables. (Haserodt and others, 2017).

  5. Identification of Individual Efficiency for Barometric Pressure and Ocean Tide Load Simultaneously Acted on Deep Aquifers Adjacent to the West Pacific Ocean

    NASA Astrophysics Data System (ADS)

    Shih, David Ching-Fang

    2018-06-01

    Groundwater fluctuation usually reflects the property of aquifer in nature. Actually, water level change can be caused not only by barometric pressure changes resulted from atmospheric motion, but also by the tidal effect from nearby marine system or water body. In confined aquifer, an increase in barometric pressure usually will cause a decrease in water level in well to an amount described by the barometric efficiency. The barometric efficiency can be also used as a correction factor to remove barometric effects on water levels in wells during an aquifer test. With the rise of the tidal sea on the coastal aquifer, it indicates that there will be compensating increases of water pressure and stress in the skeleton of aquifer. External forcing on groundwater level in the coastal aquifer, such as barometric effect and tidal sea, usually affect the water level to fluctuate with different phases to some extent. An adaptive adjustment to remove the combination of barometric and oceanic tidal efficiency is presented in this study. This research suggests that the presented formula can simultaneously identify the individual efficiency for barometric effect and load of tidal sea considering their combined observation of groundwater level in aquifer system. An innovative application has been demonstrated for the deep aquifers adjacent to the West Pacific Ocean.

  6. Analysis of High Plains Resource Risk and Economic Impacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tidwell, Vincent C.; Vargas, Vanessa N; Jones, Shannon M

    2016-04-01

    The importance of the High Plains Aquifer is broadly recognized as is its vulnerability to continued overuse. T his study e xplore s how continued depletions of the High Plains Aquifer might impact both critical infrastructure and the economy at the local, r egional , and national scale. This analysis is conducted at the county level over a broad geographic region within the states of Kansas and Nebraska. In total , 140 counties that overlie the High Plains Aquifer in these two states are analyzed. The analysis utilizes future climate projections to estimate crop production. Current water use and managementmore » practices are projected into the future to explore their related impact on the High Plains Aquifer , barring any changes in water management practices, regulat ion, or policy. Finally, the impact of declining water levels and even exhaustion of groundwater resources are projected for specific sectors of the economy as well as particular elements of the region's critical infrastructure.« less

  7. Water-quality characteristics and trends for selected wells possibly influenced by wastewater disposal at the Idaho National Laboratory, Idaho, 1981-2012

    USGS Publications Warehouse

    Davis, Linda C.; Bartholomay, Roy C.; Fisher, Jason C.; Maimer, Neil V.

    2015-01-01

    Volatile organic compound concentration trends were analyzed for nine aquifer wells. Trend test results indicated an increasing trend for carbon tetrachloride for the Radioactive Waste Management Complex Production Well for the period 1987–2012; however, trend analyses of data collected since 2005 show no statistically significant trend indicating that engineering practices designed to reduce movement of volatile organic compounds to the aquifer may be having a positive effect on the aquifer.

  8. A Science Plan for a Comprehensive Regional Assessment of the Atlantic Coastal Plain Aquifer System in Maryland

    USGS Publications Warehouse

    Shedlock, Robert J.; Bolton, David W.; Cleaves, Emery T.; Gerhart, James M.; Nardi, Mark R.

    2007-01-01

    The Maryland Coastal Plain region is, at present, largely dependent upon ground water for its water supply. Decades of increasing pumpage have caused ground-water levels in parts of the Maryland Coastal Plain to decline by as much as 2 feet per year in some areas of southern Maryland. Continued declines at this rate could affect the long-term sustainability of ground-water resources in Maryland's heavily populated Coastal Plain communities and the agricultural industry of the Eastern Shore. In response to a recommendation in 2004 by the Advisory Committee on the Management and Protection of the State's Water Resources, the Maryland Geological Survey and the U.S. Geological Survey have developed a science plan for a comprehensive assessment that will provide new scientific information and new data management and analysis tools for the State to use in allocating ground water in the Coastal Plain. The comprehensive assessment has five goals aimed at improving the current information and tools used to understand the resource potential of the aquifer system: (1) document the geologic and hydrologic characteristics of the aquifer system in the Maryland Coastal Plain and appropriate areas of adjacent states; (2) conduct detailed studies of the regional ground-water-flow system and water budget for the aquifer system; (3) improve documentation of patterns of water quality in all Coastal Plain aquifers, including the distribution of saltwater; (4) enhance ground-water-level, streamflow, and water-quality-monitoring networks in the Maryland Coastal Plain; and (5) develop science-based tools to facilitate sound management of the ground-water resources in the Maryland Coastal Plain. The assessment, as designed, will be conducted in three phases and if fully implemented, is expected to take 7 to 8 years to complete. Phase I, which was initiated in January 2006, is an effort to assemble all the information and investigation tools needed to do a more comprehensive assessment of the aquifer system. The work will include updating the hydrogeologic framework, developing a Geographic Information System-based aquifer information system, refinement of water-use information, assessment of existing water-quality data, and development of detailed plans for ground-water-flow and management models. Phase II is an intensive study phase during which a regional ground-water-flow model will be developed and calibrated for the entire region of Maryland in the Atlantic Coastal Plain as well as appropriate areas of Delaware and Virginia. The model will be used to simulate flow and water levels in the aquifer system and to study the water budget of the system. The model analysis will be based on published information but will be supplemented with field investigations of recharge and leakage in the aquifer system. Localized and finely discretized ground-water-flow models that are embedded in the regional model will be developed for selected areas of heavy withdrawals. Other modeling studies will be conducted to better understand flow in the unconfined parts of the aquifer system and to support the recharge studies. Phase II will also include selected water-quality studies and a study to determine how hydrologic and water-quality-monitoring networks need to be enhanced to appropriately assess the sustainability of the Coastal Plain aquifer system. Phase III will be largely devoted to the development and application of a ground-water optimization model. This model will be linked to the ground-water-flow model to create a model package that can be used to test different water-management scenarios. The management criteria that will be used to develop these scenarios will be determined in consultation with a variety of state and local stakeholders and policy makers in Phases I and II of the assessment. The development of the aquifer information system is a key component of the assessment. The system will store all relevant aquifer data

  9. Water type and concentration of dissolved solids, chloride, and sulfate in water from the St. Francois aquifer in Missouri, Arkansas, Kansas, and Oklahoma

    USGS Publications Warehouse

    Imes, Jeffrey L.; Davis, J.V.

    1990-01-01

    The St. Francois aquifer, the lowermost of three regional aquifers that form part of the Ozark Plateaus aquifer system, is composed of water-bearing sandstone and dolostone of Late Cambrian age. The aquifer was studied as part of the Central Midwest Regional Aquifer-System Analysis (CMRASA, Jorgensen and Signor, 1981), a study of regional aquifer systems in the midcontinent United States that includes parts of 10 States. Because of its significance as a source of freshwater in and adjacent to the Ozark Plateaus province (index map) of Missouri, Arkansas, Kansas, and Oklahoma, a subregional project was established to investigate the Ozark Plateaus aquifer system in more detail than the regional study could provide.The geologic and hydrologic relation between the Ozark Plateaus aquifer system and other regional aquifer systems of the Midwest is presented in Jorgensen an others (in press). The relation of the St. Francois aquifer to the Ozark Plateaus aquifer system is explained in Imes [in press (a)]. A companion publication, Imes [in press (b)], contains contour maps of the altitude of the top, thickness, and potentiometric surface of the St. Francois aquifer. This report contains maps that show water type and concentration of dissolved solids, chloride, and sulfate in water from the St. Francois aquifer. Most of the data from which these maps are compiled is stored in the CMRASA hydrochemical data base (R.B. Leonard, U.S. Geological Survey, written commun., 1986). Only water quality analyses that ionically balanced to within 10 percent are included in this report. Because few water wells are completed in the St. Francois aquifer beyond the vicinity of the St. Francois Mountains in southeastern Missouri (index map), water-quality data, with few exceptions, are limited to a relatively small area near the outcrop of the aquifer.

  10. Detecting a Defective Casing Seal at the Top of a Bedrock Aquifer.

    PubMed

    Richard, Sandra K; Chesnaux, Romain; Rouleau, Alain

    2016-03-01

    An improperly sealed casing can produce a direct hydraulic connection between two or more originally isolated aquifers with important consequences regarding groundwater quantity and quality. A recent study by Richard et al. (2014) investigated a monitoring well installed in a fractured rock aquifer with a defective casing seal at the soil-bedrock interface. A hydraulic short circuit was detected that produced some leakage between the rock and the overlying deposits. A falling-head permeability test performed in this well showed that the usual method of data interpretation is not valid in this particular case due to the presence of a piezometric error. This error is the direct result of the preferential flow originating from the hydraulic short circuit and the subsequent re-equilibration of the piezometric levels of both aquifers in the vicinity of the inlet and the outlet of the defective seal. Numerical simulations of groundwater circulation around the well support the observed impact of the hydraulic short circuit on the results of the falling-head permeability test. These observations demonstrate that a properly designed falling-head permeability test may be useful in the detection of defective casing seals. © 2015, National Ground Water Association.

  11. Evaluation of field methods for vertical high resolution aquifer characterization

    NASA Astrophysics Data System (ADS)

    Vienken, T.; Tinter, M.; Rogiers, B.; Leven, C.; Dietrich, P.

    2012-12-01

    The delineation and characterization of subsurface (hydro)-stratigraphic structures is one of the challenging tasks of hydrogeological site investigations. The knowledge about the spatial distribution of soil specific properties and hydraulic conductivity (K) is the prerequisite for understanding flow and fluid transport processes. This is especially true for heterogeneous unconsolidated sedimentary deposits with a complex sedimentary architecture. One commonly used approach to investigate and characterize sediment heterogeneity is soil sampling and lab analyses, e.g. grain size distribution. Tests conducted on 108 samples show that calculation of K based on grain size distribution is not suitable for high resolution aquifer characterization of highly heterogeneous sediments due to sampling effects and large differences of calculated K values between applied formulas (Vienken & Dietrich 2011). Therefore, extensive tests were conducted at two test sites under different geological conditions to evaluate the performance of innovative Direct Push (DP) based approaches for the vertical high resolution determination of K. Different DP based sensor probes for the in-situ subsurface characterization based on electrical, hydraulic, and textural soil properties were used to obtain high resolution vertical profiles. The applied DP based tools proved to be a suitable and efficient alternative to traditional approaches. Despite resolution differences, all of the applied methods captured the main aquifer structure. Correlation of the DP based K estimates and proxies with DP based slug tests show that it is possible to describe the aquifer hydraulic structure on less than a meter scale by combining DP slug test data and continuous DP measurements. Even though correlations are site specific and appropriate DP tools must be chosen, DP is reliable and efficient alternative for characterizing even strongly heterogeneous sites with complex structured sedimentary aquifers (Vienken et al. 2012). References: Vienken, T., Leven, C., and Dietrich, P. 2012. Use of CPT and other direct push methods for (hydro-) stratigraphic aquifer characterization — a field study. Canadian Geotechnical Journal, 49(2): 197-206. Vienken, T., and Dietrich, P. 2011. Field evaluation of methods for determining hydraulic conductivity from grain size data. Journal of Hydrology, 400(1-2): 58-71.

  12. Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic Conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

    USGS Publications Warehouse

    Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.

    2010-01-01

    Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative to volcanic-rock units is exemplified by the large difference in their estimated maximum hydraulic conductivity; 4,000 and 400 feet per day, respectively. Simulated minimum estimates of hydraulic conductivity are inexact and represent the lower detection limit of the method. Minimum thicknesses of lithologic intervals also were defined for comparing AnalyzeHOLE results to hydraulic properties in regional ground-water flow models.

  13. Assessment of Well Safety from Pressure and Temperature-Induced Damage during CO2 Injection in Deep Saline Aquifers

    NASA Astrophysics Data System (ADS)

    Singh, A. K.; Delfs, J.; Goerke, U.; Kolditz, O.

    2013-12-01

    Carbon dioxide Capture and Storage (CCS) technology is known for disposing a specific amount of CO2 from industrial release of flue gases into a suitable storage where it stays for a defined period of time in a safe way. Types of storage sites for CO2 are depleted hydrocarbon reservoirs, unmineable coal seams and saline aquifers. In this poster, we address the problem of CO2 sequestration into deep saline aquifers. The main advantage of this kind of site for the CO2 sequestration is its widespread geographic distribution. However, saline aquifers are very poorly characterized and typically located at one kilometer depth below the earth's surface. To demonstrate that supercritical CO2 injection into deep saline aquifers is technically and environmentally safe, it is required to perform thermo-hydro-mechanical analysis of failure moods with numerical models. In the poster, we present simple process-catching benchmark for testing the scenario of compressed CO2 injection into a multi- layered saline aquifer.The pores of the deformable matrix are initially filled with saline water at hydrostatic pressure and geothermal temperature conditions. This benchmark investigates (i) how the mechanical and thermal stresses enhance the permeability for CO2 migration; and (ii) subsequent failures mode, i.e., tensile, and shear failures. The tensile failure occurs when pore fluid pressure exceeds the principle stress whereas the Mohr-Coulomb failure criterion defines the shear failure mode. The thermo-hydro-mechanical (THM) model is based on a ';multi-componential flow' module . The coupled system of balance equations is solvedin the monolithic way. The Galerkin finite element approach is used for spatial discretization, whereas temporal discretization is performed with a generalized single step scheme. This numerical module has been implemented in the open-source scientific software OpenGeoSys.

  14. Aquifers as indicators of volcanic unrest - models of hydrological responses to magmatic activity and their geophysical signals

    NASA Astrophysics Data System (ADS)

    Strehlow, Karen; Gottsmann, Jo

    2014-05-01

    Aquifers respond to and modify the surface expressions of magmatic activity, and they can also become agents of unrest themselves. Therefore, monitoring the hydrology can provide a valuable window into subsurface processes in volcanic areas. Interpretations of unrest signals as groundwater responses to changes in the magmatic system can be found for many volcanoes. Changes in temperature and strain conditions, seismic excitation or the injection of magmatic fluids into hydrothermal systems are just a few of the proposed processes induced by magmatic activity that affect the local hydrology. Aquifer responses are described to include changes in water table levels, changes in temperature or composition of hydrothermal waters and pore pressure-induced ground deformation. We can observe these effects at the surface via geophysical and geochemical signals. To fully to utilise these indicators as monitoring and forecasting tools, however, it is necessary to improve our still poor understanding of the ongoing mechanisms in the interactions of hydrological and magmatic systems. An extensive literature research provided an overview on reported effects, which we investigate in detail using numerical modelling. The hydrogeophysical study uses finite element analysis to quantitatively test proposed mechanisms of aquifer excitation and the resultant geophysical signals. We present a set of generic models for two typical volcanic landforms - a stratovolcano and a caldera - that simulate the interaction between deeper magmatic systems with shallow-seated aquifers, focusing on strain and temperature effects. They predict pore pressure induced hydraulic head changes in the aquifer as well as changing groundwater temperatures and strain induced fluid migration. Volcano observatories can track these hydrological effects for example with potential field investigations or the monitoring of wells. The models allow us to explore the parameter space, contributing to a better understanding of the coupling of these two highly complex systems. Our results provide further insight into the subsurface processes at volcanic systems and will aid the evaluation of unrest signals with potential for improved eruption forecasting.

  15. Arsenic contamination of drinking water in Ireland: A spatial analysis of occurrence and potential risk.

    PubMed

    McGrory, Ellen R; Brown, Colin; Bargary, Norma; Williams, Natalya Hunter; Mannix, Anthony; Zhang, Chaosheng; Henry, Tiernan; Daly, Eve; Nicholas, Sarah; Petrunic, Barbara M; Lee, Monica; Morrison, Liam

    2017-02-01

    The presence of arsenic in groundwater has become a global concern due to the health risks from drinking water with elevated concentrations. The Water Framework Directive (WFD) of the European Union calls for drinking water risk assessment for member states. The present study amalgamates readily available national and sub-national scale datasets on arsenic in groundwater in the Republic of Ireland. However, due to the presence of high levels of left censoring (i.e. arsenic values below an analytical detection limit) and changes in detection limits over time, the application of conventional statistical methods would inhibit the generation of meaningful results. In order to handle these issues several arsenic databases were integrated and the data modelled using statistical methods appropriate for non-detect data. In addition, geostatistical methods were used to assess principal risk components of elevated arsenic related to lithology, aquifer type and groundwater vulnerability. Geographic statistical methods were used to overcome some of the geographical limitations of the Irish Environmental Protection Agency (EPA) sample database. Nearest-neighbour inverse distance weighting (IDW) and local indicator of spatial association (LISA) methods were used to estimate risk in non-sampled areas. Significant differences were also noted between different aquifer lithologies, indicating that Rhyolite, Sandstone and Shale (Greywackes), and Impure Limestone potentially presented a greater risk of elevated arsenic in groundwaters. Significant differences also occurred among aquifer types with poorly productive aquifers, locally important fractured bedrock aquifers and regionally important fissured bedrock aquifers presenting the highest potential risk of elevated arsenic. No significant differences were detected among different groundwater vulnerability groups as defined by the Geological Survey of Ireland. This research will assist management and future policy directions of groundwater resources at EU level and guide future research focused on understanding arsenic mobilisation processes to facilitate in guiding future development, testing and treatment requirements of groundwater resources. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Natural background levels and threshold values for groundwater in fluvial Pleistocene and Tertiary marine aquifers in Flanders, Belgium

    NASA Astrophysics Data System (ADS)

    Coetsiers, Marleen; Blaser, Petra; Martens, Kristine; Walraevens, Kristine

    2009-05-01

    Aquifers from the same typology can have strongly different groundwater chemistry. Deducing the groundwater quality of less well-characterized aquifers from well-documented aquifers belonging to the same typology should be done with great reserve, and can only be considered as a preliminary approach. In the EU’s 6th FP BRIDGE project “Background cRiteria for the IDentification of Groundwater thrEsholds”, a methodology for the derivation of threshold values (TV) for groundwater bodies is proposed. This methodology is tested on four aquifers in Flanders of the sand and gravel typology. The methodology works well for all but the Ledo-Paniselian aquifer, where the subdivision into a fresh and saline part is disproved, as a gradual natural transition from fresh to saline conditions in the aquifer is observed. The 90 percentile is proposed as natural background level (NBL) for the unconfined Pleistocene deposits, ascribing the outliers to possible influence of pollution. For the Tertiary aquifers, high values for different parameters have a natural origin and the 97.7 percentile is preferred as NBL. The methodology leads to high TVs for parameters presenting low NBL, when compared to the standard used as a reference. This would allow for substantial anthropogenic inputs of these parameters.

  17. Field, laboratory, and modeling investigation of the skin effect at wells with slotted casing, Boise Hydrogeophysical Research Site

    NASA Astrophysics Data System (ADS)

    Barrash, Warren; Clemo, Tom; Fox, Jessica J.; Johnson, Timothy C.

    2006-07-01

    Understanding and quantification of wellbore skin improves our ability to accurately measure or estimate hydrologic parameters with tests at wells such as pumping tests, flowmeter tests, and slug tests. This paper presents observations and results from a series of field, laboratory, and modeling tests which, together, explain the source of wellbore skin at wells at a research wellfield and which support estimation of skin thickness ( ds) and skin hydraulic conductivity ( Ks). Positive wellbore skin effects were recognized at wells in the shallow, unconfined, coarse-grained fluvial aquifer at the Boise Hydrogeophysical Research Site (BHRS). Well development efforts at the BHRS removed residual drilling fines but only marginally reduced the skin effect. Likely causes for the remaining wellbore skin effect were examined; partial clogging of screen slots with sand is consistent with field observations and can account for the magnitude of wellbore skin effect observed. We then use the WTAQ code ( Barlow and Moench, 1999) with a redefinition of the term for delayed observation well response to include skin effects at observation wells (in addition to pumping wells) in order to analyze aquifer tests at the BHRS for average Ks values at individual wells. Systematic differences in Ks values are recognized in results at pumping ( Ks_Q) and observation ( Ks_obs) wells: larger values are seen at observation wells (average Ks_obs=0.0023 cm/s) than pumping wells. Two possible causes are recognized for the occurrence of higher Ks values at observation wells than pumping wells: (1) flow diversion between aquifer layers on approach to a pumping well with positive skin; and (2) larger portion of flow passing through lower-K zones in the heterogeneous aquifer near the pumping well than the observation wells due to strongly radially convergent flow near the pumping well. For the well-aquifer system at the BHRS, modeling analyses of drawdown vs time at observation wells provide better Ks estimates than those from pumping wells.

  18. Drilling, construction, and aquifer-test data from wells 3-3307-20 and -21, Thompson Corner exploratory wells I and II, Oahu, Hawaii

    USGS Publications Warehouse

    Presley, T.K.; Oki, D.S.

    1996-01-01

    The Thompson Corner exploratory wells I and II (State well numbers 3-3307-20 and -21) were drilled near Thompson Corner, about 2.2 miles south-southwest of the town of Haleiwa. The wells are located on agricultural land in the Waialua ground-water area. The wells are about 50 feet apart and penetrate about 90 feet into the ground water. Aquifer tests were conducted using well 3-3307-20 as a pumping well and well 3-3307-21 as an observation well. Well-construction data, logs of drilling notes, geologic descriptions for the samples, and aquifer-test data are presented for the wells. The wells are two of twelve exploratory wells drilled in the north-central Oahu area between July 1993 and May 1994 in cooperation with the Honolulu Board of Water Supply.

  19. Estimation of the transmissivity of thin leaky-confined aquifers from single-well pumping tests

    NASA Astrophysics Data System (ADS)

    Worthington, Paul F.

    1981-01-01

    Data from the quasi-equilibrium phases of a step-drawdown test are used to evaluate the coefficient of non-linear head losses subject to the assumption of a constant effective well radius. After applying a well-loss correction to the observed drawdowns of the first step, an approximation method is used to estimate a pseudo-transmissivity of the aquifer from a single value of time-variant drawdown. The pseudo-transmissivities computed for each of a sequence of values of time pass through a minimum when there is least manifestation of casing-storage and leakage effects, phenomena to which pumping-test data of this kind are particularly susceptible. This minimum pseudo-transmissivity, adjusted for partial penetration effects where appropriate, constitutes the best possible estimate of aquifer transmissivity. The ease of application of the overall procedure is illustrated by a practical example.

  20. Combined use of heat and saline tracer to estimate aquifer properties in a forced gradient test

    NASA Astrophysics Data System (ADS)

    Colombani, N.; Giambastiani, B. M. S.; Mastrocicco, M.

    2015-06-01

    Usually electrolytic tracers are employed for subsurface characterization, but the interpretation of tracer test data collected by low cost techniques, such as electrical conductivity logging, can be biased by cation exchange reactions. To characterize the aquifer transport properties a saline and heat forced gradient test was employed. The field site, located near Ferrara (Northern Italy), is a well characterized site, which covers an area of 200 m2 and is equipped with a grid of 13 monitoring wells. A two-well (injection and pumping) system was employed to perform the forced gradient test and a straddle packer was installed in the injection well to avoid in-well artificial mixing. The contemporary continuous monitor of hydraulic head, electrical conductivity and temperature within the wells permitted to obtain a robust dataset, which was then used to accurately simulate injection conditions, to calibrate a 3D transient flow and transport model and to obtain aquifer properties at small scale. The transient groundwater flow and solute-heat transport model was built using SEAWAT. The result significance was further investigated by comparing the results with already published column experiments and a natural gradient tracer test performed in the same field. The test procedure shown here can provide a fast and low cost technique to characterize coarse grain aquifer properties, although some limitations can be highlighted, such as the small value of the dispersion coefficient compared to values obtained by natural gradient tracer test, or the fast depletion of heat signal due to high thermal diffusivity.

  1. Hydrogeology and chemical quality of water and soil at Carroll Island, Aberdeen Proving Ground, Maryland

    USGS Publications Warehouse

    Tenbus, F.J.; Phillips, S.W.

    1996-01-01

    Carroll Island was used for open-air testing of chemical warfare agents from the late 1940's until 1971. Testing and disposal activities weresuspected of causing environmental contamination at 16 sites on the island. The hydrogeology and chemical quality of ground water, surface water, and soil at these sites were investigated with borehole logs, environmental samples, water-level measurements, and hydrologic tests. A surficial aquifer, upper confining unit, and upper confined aquifer were defined. Ground water in the surficial aquifer generally flows from the east-central part of the island toward the surface-water bodies, butgradient reversals caused by evapotranspiration can occur during dry seasons. In the confined aquifer, hydraulic gradients are low, and hydraulic head is affected by tidal loading and by seasonal pumpage from the west. Inorganic chemistry in the aquifers is affected by brackish-water intrusion from gradient reversals and by dissolution ofcarboniferous shell material in the confining unit.The concentrations of most inorganic constituents probably resulted from natural processes, but some concentrations exceeded Federal water-quality regulations and criteria. Organic compounds were detected in water and soil samples at maximum concentrations of 138 micrograms per liter (thiodiglycol in surface water) and 12 micrograms per gram (octadecanoic acid in soil).Concentrations of organic compounds in ground water exceeded Federal drinking-water regulations at two sites. The organic compounds that weredetected in environmental samples were variously attributed to natural processes, laboratory or field- sampling contamination, fallout from industrial air pollution, and historical military activities.

  2. Hydrogeology and hydrologic conditions of the Northern Atlantic Coastal Plain aquifer System from Long Island, New York, to North Carolina

    USGS Publications Warehouse

    Masterson, John P.; Pope, Jason P.; Monti, Jack; Nardi, Mark R.; Finkelstein, Jason S.; McCoy, Kurt J.

    2013-11-14

    Updates to the regional hydrologic budget include revised estimates of aquifer recharge, water use and streamflow data. Inflow to the aquifer system of about 20,000 million gallons per day (Mgal/d) includes 19,600 Mgal/d from recharge from precipitation, 200 Mgal/d of recharge from wastewater via onsite domestic septic systems, and 200 Mgal/d from the release of water from aquifer storage. Outflow from the aquifer system includes groundwater discharge to streams (11,900 Mgal/d), groundwater withdrawals (1,500 Mgal/d), and groundwater discharge to coastal waters (6,600 Mgal/d). A numerical modeling analysis is required to improve this hydrologic budget calculation and to forecast future changes in water levels and aquifer storage caused by groundwater withdrawals, land-use changes, and the effects of climate variability and change.

  3. An analytic data analysis method for oscillatory slug tests.

    PubMed

    Chen, Chia-Shyun

    2006-01-01

    An analytical data analysis method is developed for slug tests in partially penetrating wells in confined or unconfined aquifers of high hydraulic conductivity. As adapted from the van der Kamp method, the determination of the hydraulic conductivity is based on the occurrence times and the displacements of the extreme points measured from the oscillatory data and their theoretical counterparts available in the literature. This method is applied to two sets of slug test response data presented by Butler et al.: one set shows slow damping with seven discernable extremities, and the other shows rapid damping with three extreme points. The estimates of the hydraulic conductivity obtained by the analytic method are in good agreement with those determined by an available curve-matching technique.

  4. Identification of pumping influences in long-term water level fluctuations.

    PubMed

    Harp, Dylan R; Vesselinov, Velimir V

    2011-01-01

    Identification of the pumping influences at monitoring wells caused by spatially and temporally variable water supply pumping can be a challenging, yet an important hydrogeological task. The information that can be obtained can be critical for conceptualization of the hydrogeological conditions and indications of the zone of influence of the individual pumping wells. However, the pumping influences are often intermittent and small in magnitude with variable production rates from multiple pumping wells. While these difficulties may support an inclination to abandon the existing dataset and conduct a dedicated cross-hole pumping test, that option can be challenging and expensive to coordinate and execute. This paper presents a method that utilizes a simple analytical modeling approach for analysis of a long-term water level record utilizing an inverse modeling approach. The methodology allows the identification of pumping wells influencing the water level fluctuations. Thus, the analysis provides an efficient and cost-effective alternative to designed and coordinated cross-hole pumping tests. We apply this method on a dataset from the Los Alamos National Laboratory site. Our analysis also provides (1) an evaluation of the information content of the transient water level data; (2) indications of potential structures of the aquifer heterogeneity inhibiting or promoting pressure propagation; and (3) guidance for the development of more complicated models requiring detailed specification of the aquifer heterogeneity. Copyright © 2010 The Author(s). Journal compilation © 2010 National Ground Water Association.

  5. Application of multivariate statistical analysis and hydrochemical and isotopic investigations for evaluation of groundwater quality and its suitability for drinking and agriculture purposes: case of Oum Ali-Thelepte aquifer, central Tunisia.

    PubMed

    Hassen, Imen; Hamzaoui-Azaza, Fadoua; Bouhlila, Rachida

    2016-03-01

    Groundwater plays a dominant role in arid regions; it is among the most available water resources in Tunisia. Located in northwestern Tunisia, Oum Ali-Thelepte is a deep Miocene sedimentary aquifer, where groundwater is the most important source of water supply. The aim of the study is to investigate the hydrochemical processes leading to mineralization and to assess water quality with respect to agriculture and drinking for a better management of groundwater resources. To achieve such objectives, water analysis was carried out on 16 groundwater samples collected during January-February 2014. Stable isotopes and 26 hydrochemical parameters were examined. The interpretation of these analytical data showed that the concentrations of major and trace elements were within the permissible level for human use. The distribution of mineral processes in this aquifer was identified using conventional classification techniques, suggesting that the water facies gradually changes from Ca-HCO3 to Mg-SO4 type and are controlled by water-rock interaction. These results were endorsed using multivariate statistical methods such as principal component analysis and cluster analysis. The sustainability of groundwater for drinking and irrigation was assessed based on the water quality index (WQI) and on Wilcox and Richards's diagrams. This aquifer has been classified as "excellent water" serving good irrigation in the area. As for the stable isotope, the measurements showed that groundwater samples lay between global meteoric water line (GMWL) and LMWL; hence, this arrangement signifies that the recharge of the Oum Ali-Thelepte aquifer is ensured by rainwater infiltration through mountains in the border of the aquifer without evaporation effects.

  6. Hydrogeology of the gray limestone aquifer in southern Florida

    USGS Publications Warehouse

    Reese, Ronald S.; Cunningham, Kevin J.

    2000-01-01

    Results from 35 new test coreholes and aquifer-test, water-level, and water-quality data were combined with existing hydrogeologic data to define the extent, thickness, hydraulic properties, and degree of confinement of the gray limestone aquifer in southern Florida. This aquifer, previously known to be present only in southeastern Florida (Miami-Dade, Broward, and Palm Beach Counties) below, and to the west of, the Biscayne aquifer, extends over most of central-south Florida, including eastern and central Collier County and southern Hendry County; it is the same as the lower Tamiami aquifer to the north, and it becomes the water-table aquifer and the upper limestone part of the lower Tamiami aquifer to the west. The aquifer generally is composed of gray, shelly, lightly to moderately cemented limestone with abundant shell fragments or carbonate sand, abundant skeletal moldic porosity, and minor quartz sand. The gray limestone aquifer comprises the Ochopee Limestone of the Tamiami Formation, and, in some areas, the uppermost permeable part of an unnamed formation principally composed of quartz sand. Underlying the unnamed formation is the Peace River Formation of the upper Hawthorn Group, the top of which is the base of the surficial aquifer system. Overlying the aquifer and providing confinement in much of the area is the Pinecrest Sand Member of the Tamiami Formation. The thickness of the aquifer is comparatively uniform, generally ranging from 30 to 100 feet. The unnamed formation part of the aquifer is up to 20 feet thick. The Ochopee Limestone accumulated in a carbonate ramp depositional system and contains a heterozoan carbonate-particle association. The principal rock types of the aquifer are pelecypod lime rudstones and floatstones and permeable quartz sands and sandstones. The pore types are mainly intergrain and separate vug (skeletal-moldic) pore spaces. The rock fabric and associated primary and secondary pore spaces combine to form a dual diffuse-carbonate and conduit flow system capable of producing high values of hydraulic conductivity. Transmissivity values of the aquifer are commonly greater than 50,000 feet squared per day to the west of Miami-Dade and Broward Counties. Hydraulic conductivity ranges from about 200 to 12,000 feet per day and generally increases from east to west; an east-to-west shallowing of the depositional profile of the Ochopee Limestone carbonate ramp contributes to this spatial trend. The aquifer contains two areas of high transmissivity, both of which trend northwest-southeast. One area extends through southern Hendry County. The other area extends through eastern Collier County, with a transmissivity as high as 300,000 feet squared per day; in this area, the aquifer is structurally high, the top of the aquifer is close to land surface, and it is unconfined to semiconfined. The confinement of the aquifer is good to the north and east in parts of southern Hendry, Palm Beach, Collier, Broward, and Miami-Dade Counties. In these areas, the upper confining unit approaches or is greater than 50 feet thick, and vertical leakance is less than 1.0 x 10-3 l/day. In most of the study area, the specific conductance in water from the gray limestone aquifer is 1,500 microsiemens per centimeter or less (chloride concentration of about 250 milligrams per liter or less). Areas where specific conductance is greater than 3,000 microsiemens per centimeter are found where there is a low horizontal-head gradient and the upper confining unit is greater than 50 feet thick. An area with specific conductance less than 1,500 microsiemens per centimeter extends from southern Hendry County to the southeast into western Broward County and coincides with an area of high transmissivity. However, much of this area has good confinement. The potentiometric gradient also is to the southeast in much of the area, and this area of low specific conductance is probably caused by a relatively rapid downgradient movement of fres

  7. AEM and NMR: Tools for the Future of Groundwater Management

    NASA Astrophysics Data System (ADS)

    Abraham, J. D.; Cannia, J. C.; Lawrie, K.

    2012-12-01

    Within the world, understanding groundwater resources and their management are growing in importance to society as groundwater resources are stressed by drought and continued development. To minimize conflicts, tools and techniques need to be applied to support knowledge-based decisions and management. Airborne electromagnetic (AEM) surveys provide high-quality subsurface data not available from any other source for building the complex hydrogeologic frameworks needed by water-resource managers for effective groundwater management. Traditionally, point data, such as borehole logs, borehole geophysics, surface geophysics, and aquifer tests were interpolated over long distances to create hydrogeologic frameworks. These methods have enjoyed a long history of being the best available technology to inform our understanding of groundwater and how it moves. The AEM techniques proivde pathway for geoscientists to follow to develop more accurate descriptions of the hydrogeological framework. However, the critical and challenging measurements in characterizing aquifers include effective porosity and hydraulic conductivity. These parameters are not reliable derived from AEM. Typically, values for effective porosity and hydraulic conductivity are derived by lithological comparisons with published data; direct measurements of hydraulic conductivity acquired by a few constant head aquifer tests or slug tests; and expensive and time consuming laboratory measurements of cores which can be biased by sampling and the difficulty of making measurements on unconsolidated materials. Aquifer tests are considered to be the best method to gather information on hydraulic conductivity but are rare because of cost and difficult logistics. Also they are unique in design and interpretation from site to site. Nuclear Magnetic Resonance (NMR) can provide a direct measurement of the presence of water in the pore space of aquifer materials. Detection and direct measurement is possible due to the nuclear magnetization of the hydrogen (protons) in the water. These measurements are the basis of the familiar MRI (magnetic resonance imaging) in medical applications. NMR is also widely used in logging applications within the petroleum industry. Effective porosity values were derived directly from the borehole and surface NMR data, and hydraulic conductivity values were calculated using empirical relationships calibrated and verified with few laboratory permeameter and aquifer tests. NMR provides measurements of the effective porosity and hydraulic conductivity at a resolution not possible using traditional methods. Unlike aquifer tests, NMR logs are not unique in design and are applied in similar fashion from borehole to borehole providing a standard way of measuring hydraulic properties. When the hydraulic properties from the NMR are integrated with hydrogeological framework interpretations of AEM data large areas can be characterized. This allows a much more robust method for conceptualizing groundwater models then simply using previously published data for assigning effective porosity and hydraulic conductivity. Examples from the North Platte River Basin in Nebraska and the Murray Darling Basin of Australia illustrate that borehole and surface NMR allows superior, rapid measurements of the complexities of aquifers within when integrated with AEM.

  8. Graphical viewer for displaying locations and logs of selected wells and test holes in Putnam County, New York

    USGS Publications Warehouse

    Wolcott, Stephen W.

    2005-01-01

    Aquifers (water bearing geologic units) are the primary source of drinking water in most of Putnam County, N.Y. The principal sources of data used to define the geometry and hydraulic characteristics of aquifers are the logs of wells and test holes within the county. This report explains how to use a graphical viewer, available on the World Wide Web (http://ny.water.usgs.gov/pubs/of/of051198), to locate selected wells and test holes in Putnam County and display their logs.

  9. Hydrogeology and simulation of flow between the alluvial and bedrock aquifers in the upper Black Squirrel Creek basin, El Paso County, Colorado

    USGS Publications Warehouse

    Watts, K.R.

    1995-01-01

    Anticipated increases in pumping from the bedrock aquifers in El Paso County potentially could affect the direction and rate of flow between the alluvial and bedrock aquifers and lower water levels in the overlying alluvial aquifer. The alluvial aquifer underlies about 90 square miles in the upper Black Squirrel Creek Basin of eastern El Paso County. The alluvial aquifer consists of unconsolidated alluvial deposits that unconformably overlie siltstones, sandstones, and conglomerate (bedrock aquifers) and claystone, shale, and coal (bedrock confining units) of the Denver Basin. The bedrock aquifers (Dawson, Denver, Arapahoe, and Laramie-Fox Hills aquifers) are separated by confining units (upper and lower Denver and the Laramie confining units) and overlie a relatively thick and impermeable Pierre confining unit. The Pierre confining unit is assumed to be a no-flow boundary at the base of the alluvial/ bedrock aquifer system. During 1949-90, substantial water-level declines, as large as 50 feet, in the alluvial aquifer resulted from withdrawals from the alluvial aquifer for irrigation and municipal supplies. Average recharge to the alluvial aquifer from infiltration of precipitation and surface water was an estimated 11.97 cubic feet per second and from the underlying bedrock aquifers was an estimated 0.87 cubic foot per second. Water-level data from eight bedrock observation wells and eight nearby alluvial wells indicate that, locally, the alluvial and bedrock aquifers probably are hydraulically connected and that the alluvial aquifer in the upper Black Squirrel Creek Basin receives recharge from the Denver and Arapahoe aquifers but-locally recharges the Laramie-Fox Hills aquifer. Subsurface-temperature profiles were evaluated as a means of estimating specific discharge across the bedrock surface (the base of the alluvial aquifer). However, assumptions of the analytical method were not met by field conditions and, thus, analyses of subsurface-temperature profiles did not reliably estimate specific discharge across the bedrock surface. The vertical hydraulic diffusivity of a siltstone and sandstone in the lower Denver confining unit was estimated, by an aquifer test, to be about 8 x 10'4 square foot per day. Physical and chemical characteristics of water from the bedrock aquifers in the study area generally differ from the physical and chemical characteristics of water from the alluvial aquifer, except for the physical and chemical characteristics of water from one bedrock well, which is completed in the Laramie-Fox Hills aquifer. In the southern part of the study area, physical and chemical characteristics of ground water indicate downward flow of water from the alluvial aquifer to the Laramie-Fox Hills aquifer. A three-dimensional numerical model was used to evaluate flow of water between the alluvial aquifer and underlying bedrock. Simulation of steady-state conditions indicates that flow from the bedrock aquifers to the alluvial aquifer was about 7 percent of recharge to the alluvial aquifer, about 0.87 cubic foot per second. The potential effects of withdrawal from the alluvial and bedrock aquifers at estimated (October 1989 to September 1990) rates and from the bedrock aquifers at two larger hypothetical rates were simulated for a 50-year projection period. The model simulations indicate that water levels in the alluvial aquifer will decline an average of 8.6 feet after 50 years of pumping at estimated October 1989 to September 1990 rates. Increases in withdrawals from the bedrock aquifers in El Paso County were simulated to: (1) Capture flow that currently discharges from the bedrock aquifers to springs and streams in upland areas and to the alluvial aquifer, (2) induce flow downward from the alluvial aquifer, and (3) accelerate the rate of waterlevel decline in the alluvial aquifer.

  10. Field Measurements and Modeling of the Southeast Greenland Firn Aquifer

    NASA Astrophysics Data System (ADS)

    Miller, O. L.; Solomon, D. K.; Miège, C.; Voss, C. I.; Koenig, L.; Forster, R. R.; Schmerr, N. C.; Montgomery, L. N.; Legchenko, A.; Ligtenberg, S.

    2016-12-01

    An extensive firn aquifer forms in southeast Greenland as surface meltwater percolates through the upper seasonal snow and firn layers to depth and saturates open pore spaces. The firn aquifer is found at depths from about 10 to 35 m below the snow surface in areas with high accumulation rates and high melt rates. The firn aquifer retains significant volume of meltwater and heat within the ice sheet. The first-ever hydrologic and geochemical measurements from several boreholes drilled into the aquifer have been made 50 km upstream of Helheim Glacier terminus in SE Greenland. This field data is used with a version of the SUTRA groundwater simulator that represents the freeze/thaw process to model the hydrologic and thermal conditions of the ice sheet, including aquifer water recharge, lateral flow, and discharge. Meltwater generation during the summer season is modeled using degree day methods, and meltwater recharge to the aquifer (10-70 cm/year) is calculated using water level fluctuations and volumetric flow measurements (3e-7 to 5e-6 m3/s). Aquifer hydrologic parameters, including hydraulic conductivity (2e-5 to 4e -4 m/s), storativity, and specific discharge (3e-7 to 5e-6 m/s), are estimated from aquifer pumping tests and tracer experiments. In situ measurements were obtained using a novel heated piezometer, which advances downward through the unsaturated and saturated zones of the aquifer by melting the surrounding firn. Innovative modeling approaches blending unsaturated and saturated groundwater flow modeling and ice thermodynamics indicate the importance of surface topography controls on fluid flow within the aquifer, and forecast the nature and volume of aquifer water discharge into crevasses at the edge of the ice sheet. This pioneering study is crucial to understanding the aquifer's influence on mass balance estimates of the ice sheet.

  11. Evaluation of the fate of arsenic-contaminated groundwater at different aquifers of Thar coalfield Pakistan.

    PubMed

    Ali, Jamshed; Kazi, Tasneem G; Baig, Jameel A; Afridi, Hassan I; Arain, Mariam S; Ullah, Naeem; Brahman, Kapil D; Arain, Sadaf S; Panhwar, Abdul H

    2015-12-01

    In present study, the ground water at different aquifers was evaluated for physicochemical parameters, iron, total arsenic, total inorganic arsenic and arsenic species (arsenite and arsenate). The samples of groundwater were collected at different depths, first aquifer (AQ1) 50-60 m, second aquifer (AQ2) 100-120 m, and third aquifer (AQ3) 200-250 m of Thar coalfield, Pakistan. Total inorganic arsenic was determined by solid phase extraction using titanium dioxide as an adsorbent. The arsenite was determined by cloud point extraction using ammonium pyrrolidinedithiocarbamate as a chelating reagent, and resulted complex was extracted by Triton X-114. The resulted data of groundwater were reported in terms of basic statistical parameters, principal component, and cluster analysis. The resulted data indicated that physicochemical parameters of groundwater of different aquifers were exceeded the World Health Organization provisional guideline for drinking water except pH and SO4(2-). The positive correlation was observed between arsenic species and physicochemical parameters of groundwater except F(-) and K(+), which might be caused by geochemical minerals. Results of cluster analysis indicated that groundwater samples of AQ1 was highly contaminated with arsenic species as compared to AQ2 and AQ3 (p > 0.05).

  12. Derivation of groundwater threshold values for analysis of impacts predicted at potential carbon sequestration sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Last, G. V.; Murray, C. J.; Bott, Y.

    2016-06-01

    The U.S. Department of Energy’s (DOE’s) National Risk Assessment Partnership (NRAP) Project is developing reduced-order models to evaluate potential impacts to groundwater quality due to carbon dioxide (CO 2) or brine leakage, should it occur from deep CO 2 storage reservoirs. These efforts targeted two classes of aquifer – an unconfined fractured carbonate aquifer based on the Edwards Aquifer in Texas, and a confined alluvium aquifer based on the High Plains Aquifer in Kansas. Hypothetical leakage scenarios focus on wellbores as the most likely conduits from the storage reservoir to an underground source of drinking water (USDW). To facilitate evaluationmore » of potential degradation of the USDWs, threshold values, below which there would be no predicted impacts, were determined for each of these two aquifer systems. These threshold values were calculated using an interwell approach for determining background groundwater concentrations that is an adaptation of methods described in the U.S. Environmental Protection Agency’s Unified Guidance for Statistical Analysis of Groundwater Monitoring Data at RCRA Facilities. Results demonstrate the importance of establishing baseline groundwater quality conditions that capture the spatial and temporal variability of the USDWs prior to CO 2 injection and storage.« less

  13. Bibliography of Regional Aquifer-System Analysis Program of the US Geological Survey, 1978-91

    USGS Publications Warehouse

    Sun, Ren Jen; Weeks, John B.

    1991-01-01

    The Regional Aquifer-System Analysis (RASA) Program of the U.S. Geological Survey was initiated in 1978. The purpose of this program is to define the regional geohydrology and establish a framework of background information on geology, hydrology, and geochemistry of the Nation's important aquifer systems. This information is critically needed to develop an understanding of the Nation's major ground-water flow systems and to support better management of ground-water resources.As of May 1991, 28 of the Nation's major aquifer systems have been identified for study under this program. Of these, 17 regional aquifer-system studies have been completed, and 8 studies are ongoing. Starting in 1988, the program devoted part of its resources to compilation of a Nationwide ground-water atlas that presents a comprehensive summary of the Nation's major ground-water resources. The atlas, which is designed in a graphical format supported by descriptive text, will serve as a basic reference for the location, geography, geology, and hydrologic characteristics of the major aquifers in the Nation.This bibliography lists the published 876 reports resulting from various studies of the program, from 1978 through May 1991. The list of reports for each study is placed after a brief description of that study.

  14. Water type and concentration of dissolved solids, chloride, and sulfate in water from the Ozark aquifer in Missouri, Arkansas, Kansas, and Oklahoma

    USGS Publications Warehouse

    Imes, Jeffrey L.; Davis, J.V.

    1991-01-01

    The Ozark aquifer is a thick sequence of water-bearing dolostone, limestone, and sandstone of latest Cambrian through Middle Devonian age that is widely used as a source of water throughout the Ozark Plateaus province (index map). The Ozark aquifer is the largest of three aquifers that form part of the Ozark Plateaus aquifer system. The aquifer was studied as part of the Central Midwest Regional Aquifer-System Analysis (CMRASA; Jorgensen and Signor, 1981), a study of regional aquifer systems in the midcontinent United States that includes parts of 10States. Because of its significance as a source of freshwater in parts of Missouri, Arkansas, Kansas, and Oklahoma, a subregional project was established to investigate the Ozark Plateaus aquifer system in more detail than the regional study could provide.The geologic and hydrologic relation between the Ozark Plateaus aquifer system and other regional aquifer systems of the Midwest is presented in Jorgensen and others (in press). The relation of the Ozark aquifer to the Ozark Plateaus aquifer system is explained in Imes [in press (a)]. A companion publication, Imes [1990 (b)], contains contour maps of the altitude of the top, thickness, and potentiometric surface of the Ozark aquifer. This report contains maps that show water type and concentrations of dissolved solids, chloride, and sulfate in water from the Ozark aquifer. Most of the data from which these maps are compiled is stored in the CMRASA hydrochemical data base (R.B. Leonard, U.S. Geological Survey, written commun., 1986). Data for Oklahoma were also taken from data published by Havens (1978). The maps in this report on the Ozark subregion may contain small differences from maps in other CMRASA publications because the criteria for data selection may be different and the subregional maps may contain additional data. However, regional trends in these maps are consistent with other maps published as part of the regional project.

  15. Bibliography of Regional Aquifer-System Analysis Program of the US Geological Survey, 1978-96

    USGS Publications Warehouse

    Sun, Ren Jen; Weeks, John B.; Grubb, Hayes F.

    1997-01-01

    The Regional Aquifer-System Analysis (RASA) Program of the U.S. Geological Survey was initiated in 1978 and was completed in 1995. The purpose of this program was to define the regional geohydrology and establish a framework of background information on geology, hydrology, and geochemistry of the Nation's important aquifer systems. This information is critically needed to develop an understanding of the Nation's major ground-water flow systems and to support better management of ground-water resources. Twenty-five of the Nation's major aquifer systems were studied under this program. Starting in 1988, the program devoted part of its resources to compilation of a National Ground Water Atlas that presets a comprehensive summary of the Nation's major ground-water resources. The atlas, which is designed in a graphical format supported by descriptive text, serves as a basic reference for the location, geography, geology, and hydrologic characteristics of the major aquifers in the Nation. This bibliography lists 1,105 reports that result from various studies of the program. The list of reports for each study follows a brief description of that study.

  16. Heterogeneity of hydrodynamic properties and groundwater circulation of a coastal andesitic volcanic aquifer controlled by tectonic induced faults and rock fracturing - Martinique island (Lesser Antilles - FWI)

    NASA Astrophysics Data System (ADS)

    Vittecoq, B.; Reninger, P. A.; Violette, S.; Martelet, G.; Dewandel, B.; Audru, J. C.

    2015-10-01

    We conducted a multidisciplinary study to analyze the structure and the hydrogeological functioning of an andesitic coastal aquifer and to highlight the importance of faults and associated rock fracturing on groundwater flow. A helicopter-borne geophysical survey with an unprecedented resolution (SkyTEM) was flown over this aquifer in 2013. TDEM resistivity, total magnetic intensity, geological and hydrogeological data from 30 boreholes and two pumping tests were correlated, including one which lasted an exceptional 15 months. We demonstrate that heterogeneous hydrodynamic properties and channelized flows result from tectonically-controlled aquifer compartmentalization along the structural directions of successive tectonic phases. Significant fracturing of the central compartment results in enhanced hydrodynamic properties of the aquifer and an inverse relationship between electrical resistivity and transmissivity. Basalts within the fractured compartment have lower resistivity and higher permeability than basalts outside the compartment. Pumping tests demonstrate that the key factor is the hydraulic conductivity contrast between compartments rather than the hydrodynamic properties of the fault structure. In addition, compartmentalization and associated transmissivity contrasts protect the aquifer from seawater intrusion. Finally, unlike basaltic volcanic islands, the age of the volcanic formations is not the key factor that determines hydrodynamic properties of andesitic islands. Basalts that are several million years old (15 Ma here) have favorable hydrodynamic properties that are generated or maintained by earthquakes/faulting that result from active subduction beneath these islands, which is superimposed on their primary permeability.

  17. Hydrogeological characterization of flow system in a karstic aquifer, Seymareh dam, Iran

    NASA Astrophysics Data System (ADS)

    Behrouj Peely, Ahmad; Mohammadi, Zargham; Raeisi, Ezzatollah; Solgi, Khashayar; Mosavi, Mohammad J.; Kamali, Majid

    2018-07-01

    In order to determine the characteristics of the flow system in a karstic aquifer, an extensive hydrogeological study includes dye tracing test was conducted. The aquifer suited left abutment of Seymareh Dam, in Ravandi Anticline and discharges by more than 50 springs in the southern flank. Flow system in the aquifer is mainly controlled by the reservoir of Seymareh Dam. Time variations of the spring discharge and water table in the observation wells were highly correlated with the reservoir water level. The average groundwater velocity ranges from 0.2 to more than 14 m/h based on the dye tracing test. The probable flow paths were differentiated in two groups including the flow paths in the northern and southern flanks of Ravandi Anticline. Types of groundwater flow in the proposed flow paths are determined as diffuse or conduit flow type considering groundwater velocity and shape of the breakthrough curves. An index is proposed for differentiation of diffuse and conduit flow system based on relationship of groundwater velocity and hydraulic gradient. Dominant geometry of the flow routs (e.g., conduit diameter and fracture aperture) is estimated for the groundwater flow paths toward the springs. Based on velocity variations and variance coefficient of the water table and discharge of springs on map view a major karst conduit was probably developed in the aquifer. This research emphasizes applying of an extensive hydrogeological study for characterization of flow system in the karst aquifer.

  18. Hydrology of sand-and-gravel aquifer in central and southern Escambia County, Florida

    USGS Publications Warehouse

    Trapp, Henry

    1975-01-01

    The sand-and-gravel aquifer is the only fresh-water aquifer in the Pensacola area. Problems related to development of the aquifer include maximum safe yield, local contamination, local salt-water intrusion, corrosiveness of the water, areas of high iron concentration, and increasing nitrate concentration. The city of Pensacola is seeking hydrologic information, including water-quality data, to plan for future expansion of the water-supply system. This report summarizes the third year's findings of a 6-year study of the sand-and-gravel aquifer. Although the thickness of the aquifer locally exceeds 1,000 feet (300 metres) most of the clean sand layers are no more than 450 feet (140 metres) below land surface. The highest head is at the north edge of the area; the head is drawn down below sea level in areas of heavy pumping. Ground water moves southward from the northern half of the county to be intercepted near Cantonment. Virtually all ground water discharged south of Cantonment derives from local precipitation. The report contains maps showing concentrations of carbon dioxide, nitrate, and iron in water from the aquifer, potentiometric maps, geohydrologic sections, and lithologic and radioactive logs of test holes.

  19. Selected hydrogeologic and water-quality data from Jones Beach Island, Long Island, New York

    USGS Publications Warehouse

    Scorca, M.P.; Reilly, T.E.; Franke, O.L.

    1995-01-01

    A data-collection site was instrumented on Jones Beach Island, a barrier island south of Long Island, N.Y., to study local freshwater/ saltwater relations in the shallow ground-water system. A geologic test boring revealed about 88 feet of well-sorted glacial outwash sand above about 15 feet of Gardiners Clay, which directly overlies silty sand of the Magothy Formation. Tidal effects on water levels in Great South Bay, the upper glacial aquifer, and the Magothy aquifer were observed and quantified with a tidal gage in the bay and analog water-level recorders in the wells.Chloride concentrations in the upper Magothy aquifer were higher than expected--about 270 mg/L (milligrams per liter), and those in the upper glacial aquifer were 17,000 to 19,000 mg/L, about the same as in Great South Bay. Estimates of pressure and freshwater equivalent heads indicate that, at the data-collection site, freshwater is discharging upward from the Magothy aquifer into the salty upper glacial aquifer, but dilution by this freshwater is undetectable. The reason for the elevated chloride concentration in the Magothy aquifer cannot be determined from available hydrogeologic information.

  20. Intrinsic and specific vulnerability of groundwater in central Spain: the risk of nitrate pollution

    NASA Astrophysics Data System (ADS)

    Martínez-Bastida, Juan J.; Arauzo, Mercedes; Valladolid, Maria

    2010-05-01

    The intrinsic vulnerability of groundwater in the Comunidad de Madrid (central Spain) was evaluated using the DRASTIC and GOD indexes. Groundwater vulnerability to nitrate pollution was also assessed using the composite DRASTIC (CD) and nitrate vulnerability (NV) indexes. The utility of these methods was tested by analyzing the spatial distribution of nitrate concentrations in the different aquifers located in the study area: the Tertiary Detrital Aquifer, the Moor Limestone Aquifer, the Cretaceous Limestone Aquifer and the Quaternary Aquifer. Vulnerability maps based on these four indexes showed very similar results, identifying the Quaternary Aquifer and the lower sub-unit of the Moor Limestone Aquifer as deposits subjected to a high risk of nitrate pollution due to intensive agriculture. As far as the spatial distribution of groundwater nitrate concentrations is concerned, the NV index showed the greatest statistical significance ( p < 0.01). This new type of multiplicative model offers greater accuracy in estimations of specific vulnerability with respect to the real impact of each type of land use. The results of this study provide a basis on which to guide the designation of nitrate vulnerable zones in the Comunidad de Madrid, in line with European Union Directive 91/676/EEC.

Top