Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users.
Witteveen, Heidi J B; Rietman, Hans S; Veltink, Peter H
2015-06-01
User feedback about grasping force and hand aperture is very important in object handling with myoelectric forearm prostheses but is lacking in current prostheses. Vibrotactile feedback increases the performance of healthy subjects in virtual grasping tasks, but no extensive validation on potential users has been performed. Investigate the performance of upper-limb loss subjects in grasping tasks with vibrotactile stimulation, providing hand aperture, and grasping force feedback. Cross-over trial. A total of 10 subjects with upper-limb loss performed virtual grasping tasks while perceiving vibrotactile feedback. Hand aperture feedback was provided through an array of coin motors and grasping force feedback through a single miniature stimulator or an array of coin motors. Objects with varying sizes and weights had to be grasped by a virtual hand. Percentages correctly applied hand apertures and correct grasping force levels were all higher for the vibrotactile feedback condition compared to the no-feedback condition. With visual feedback, the results were always better compared to the vibrotactile feedback condition. Task durations were comparable for all feedback conditions. Vibrotactile grasping force and hand aperture feedback improves grasping performance of subjects with upper-limb loss. However, it should be investigated whether this is of additional value in daily-life tasks. This study is a first step toward the implementation of sensory vibrotactile feedback for users of myoelectric forearm prostheses. Grasping force feedback is crucial for optimal object handling, and hand aperture feedback is essential for reduction of required visual attention. Grasping performance with feedback is evaluated for the potential users. © The International Society for Prosthetics and Orthotics 2014.
From a meso- to micro-scale connectome: array tomography and mGRASP
Rah, Jong-Cheol; Feng, Linqing; Druckmann, Shaul; Lee, Hojin; Kim, Jinhyun
2015-01-01
Mapping mammalian synaptic connectivity has long been an important goal of neuroscience because knowing how neurons and brain areas are connected underpins an understanding of brain function. Meeting this goal requires advanced techniques with single synapse resolution and large-scale capacity, especially at multiple scales tethering the meso- and micro-scale connectome. Among several advanced LM-based connectome technologies, Array Tomography (AT) and mammalian GFP-Reconstitution Across Synaptic Partners (mGRASP) can provide relatively high-throughput mapping synaptic connectivity at multiple scales. AT- and mGRASP-assisted circuit mapping (ATing and mGRASPing), combined with techniques such as retrograde virus, brain clearing techniques, and activity indicators will help unlock the secrets of complex neural circuits. Here, we discuss these useful new tools to enable mapping of brain circuits at multiple scales, some functional implications of spatial synaptic distribution, and future challenges and directions of these endeavors. PMID:26089781
Zhuang, Jun; Vargas-Irwin, Carlos; Donoghue, John P.
2011-01-01
Intracortical microelectrode array recordings generate a variety of neural signals with potential application as control signals in neural interface systems. Previous studies have focused on single and multiunit activity, as well as low frequency local field potentials (LFPs), but have not explored higher frequency (>200 Hz) LFPs. In addition, the potential to decode three dimensional (3-D) reach and grasp kinematics based on LFPs has not been demonstrated. Here, we use mutual information and decoding analyses to probe the information content about 3-D reaching and grasping of 7 different LFP frequency bands in the range of 0.3 Hz – 400 Hz. LFPs were recorded via 96-microelectrode arrays in primary motor cortex (M1) of two monkeys performing free reaching to grasp moving objects. Mutual information analyses revealed that higher frequency bands (e.g. 100 – 200 Hz and 200 – 400 Hz) carried the most information about the examined kinematics. Furthermore, Kalman filter decoding revealed that broadband high frequency LFPs, likely reflecting multiunit activity, provided the best decoding performance as well as substantial accuracy in reconstructing reach kinematics, grasp aperture and aperture velocity. These results indicate that LFPs, especially high frequency bands, could be useful signals for neural interfaces controlling 3-D reach and grasp kinematics. PMID:20403782
Lawrence, Marc; Gross, Gion-Pitschen; Lang, Martin; Kuhn, Andreas; Keller, Thierry; Morari, Manfred
2008-08-01
New multichannel textile neuroprotheses were developed, which comprise multiple sets of transcutaneous electrode arrays and connecting wires embroidered into a fabric layer. The electrode arrays were placed on the forearm above the extrinsic finger flexors and extensors. Activation regions for selective finger flexion and wrist extension were configured by switching a subset of the array elements between cathode, anode, and off states. We present a new isometric measurement system for the assessment of finger forces and wrist torques generated using the new neuroprostheses. Finger forces (from the middle phalanxes) were recorded using five load cells mounted on a "grasp handle" that can be arbitrarily positioned in space. The hand and the grasp handle were rigidly mounted to a 6-degree of freedom load cell, and the forces and torques about the wrist were recorded. A vacuum cushion was used to comfortably fixate the forearm. The position and orientation of the forearm, wrist, fingers, and handle were recorded using a new three-dimensional position measurement system (accuracy <+/-1 mm). The measurement system was integrated into the real-time multichannel transcutaneous electrode environment, which is able to control the spatiotemporal position of multiple activation regions. Using the combined system and textile neuroprosthesis, we were able to optimize the activation regions to produce selective finger and wrist articulation, enabling improved functional grasp.
Riehle, Alexa; Wirtssohn, Sarah; Grün, Sonja; Brochier, Thomas
2013-01-01
Grasping an object involves shaping the hand and fingers in relation to the object’s physical properties. Following object contact, it also requires a fine adjustment of grasp forces for secure manipulation. Earlier studies suggest that the control of hand shaping and grasp force involve partially segregated motor cortical networks. However, it is still unclear how information originating from these networks is processed and integrated. We addressed this issue by analyzing massively parallel signals from population measures (local field potentials, LFPs) and single neuron spiking activities recorded simultaneously during a delayed reach-to-grasp task, by using a 100-electrode array chronically implanted in monkey motor cortex. Motor cortical LFPs exhibit a large multi-component movement-related potential (MRP) around movement onset. Here, we show that the peak amplitude of each MRP component and its latency with respect to movement onset vary along the cortical surface covered by the array. Using a comparative mapping approach, we suggest that the spatio-temporal structure of the MRP reflects the complex physical properties of the reach-to-grasp movement. In addition, we explored how the spatio-temporal structure of the MRP relates to two other measures of neuronal activity: the temporal profile of single neuron spiking activity at each electrode site and the somatosensory receptive field properties of single neuron activities. We observe that the spatial representations of LFP and spiking activities overlap extensively and relate to the spatial distribution of proximal and distal representations of the upper limb. Altogether, these data show that, in motor cortex, a precise spatio-temporal pattern of activation is involved for the control of reach-to-grasp movements and provide some new insight about the functional organization of motor cortex during reaching and object manipulation. PMID:23543888
Distinct neural patterns enable grasp types decoding in monkey dorsal premotor cortex.
Hao, Yaoyao; Zhang, Qiaosheng; Controzzi, Marco; Cipriani, Christian; Li, Yue; Li, Juncheng; Zhang, Shaomin; Wang, Yiwen; Chen, Weidong; Chiara Carrozza, Maria; Zheng, Xiaoxiang
2014-12-01
Recent studies have shown that dorsal premotor cortex (PMd), a cortical area in the dorsomedial grasp pathway, is involved in grasp movements. However, the neural ensemble firing property of PMd during grasp movements and the extent to which it can be used for grasp decoding are still unclear. To address these issues, we used multielectrode arrays to record both spike and local field potential (LFP) signals in PMd in macaque monkeys performing reaching and grasping of one of four differently shaped objects. Single and population neuronal activity showed distinct patterns during execution of different grip types. Cluster analysis of neural ensemble signals indicated that the grasp related patterns emerged soon (200-300 ms) after the go cue signal, and faded away during the hold period. The timing and duration of the patterns varied depending on the behaviors of individual monkey. Application of support vector machine model to stable activity patterns revealed classification accuracies of 94% and 89% for each of the two monkeys, indicating a robust, decodable grasp pattern encoded in the PMd. Grasp decoding using LFPs, especially the high-frequency bands, also produced high decoding accuracies. This study is the first to specify the neuronal population encoding of grasp during the time course of grasp. We demonstrate high grasp decoding performance in PMd. These findings, combined with previous evidence for reach related modulation studies, suggest that PMd may play an important role in generation and maintenance of grasp action and may be a suitable locus for brain-machine interface applications.
Distinct neural patterns enable grasp types decoding in monkey dorsal premotor cortex
NASA Astrophysics Data System (ADS)
Hao, Yaoyao; Zhang, Qiaosheng; Controzzi, Marco; Cipriani, Christian; Li, Yue; Li, Juncheng; Zhang, Shaomin; Wang, Yiwen; Chen, Weidong; Chiara Carrozza, Maria; Zheng, Xiaoxiang
2014-12-01
Objective. Recent studies have shown that dorsal premotor cortex (PMd), a cortical area in the dorsomedial grasp pathway, is involved in grasp movements. However, the neural ensemble firing property of PMd during grasp movements and the extent to which it can be used for grasp decoding are still unclear. Approach. To address these issues, we used multielectrode arrays to record both spike and local field potential (LFP) signals in PMd in macaque monkeys performing reaching and grasping of one of four differently shaped objects. Main results. Single and population neuronal activity showed distinct patterns during execution of different grip types. Cluster analysis of neural ensemble signals indicated that the grasp related patterns emerged soon (200-300 ms) after the go cue signal, and faded away during the hold period. The timing and duration of the patterns varied depending on the behaviors of individual monkey. Application of support vector machine model to stable activity patterns revealed classification accuracies of 94% and 89% for each of the two monkeys, indicating a robust, decodable grasp pattern encoded in the PMd. Grasp decoding using LFPs, especially the high-frequency bands, also produced high decoding accuracies. Significance. This study is the first to specify the neuronal population encoding of grasp during the time course of grasp. We demonstrate high grasp decoding performance in PMd. These findings, combined with previous evidence for reach related modulation studies, suggest that PMd may play an important role in generation and maintenance of grasp action and may be a suitable locus for brain-machine interface applications.
Continuous decoding of human grasp kinematics using epidural and subdural signals
NASA Astrophysics Data System (ADS)
Flint, Robert D.; Rosenow, Joshua M.; Tate, Matthew C.; Slutzky, Marc W.
2017-02-01
Objective. Restoring or replacing function in paralyzed individuals will one day be achieved through the use of brain-machine interfaces. Regaining hand function is a major goal for paralyzed patients. Two competing prerequisites for the widespread adoption of any hand neuroprosthesis are accurate control over the fine details of movement, and minimized invasiveness. Here, we explore the interplay between these two goals by comparing our ability to decode hand movements with subdural and epidural field potentials (EFPs). Approach. We measured the accuracy of decoding continuous hand and finger kinematics during naturalistic grasping motions in five human subjects. We recorded subdural surface potentials (electrocorticography; ECoG) as well as with EFPs, with both standard- and high-resolution electrode arrays. Main results. In all five subjects, decoding of continuous kinematics significantly exceeded chance, using either EGoG or EFPs. ECoG decoding accuracy compared favorably with prior investigations of grasp kinematics (mean ± SD grasp aperture variance accounted for was 0.54 ± 0.05 across all subjects, 0.75 ± 0.09 for the best subject). In general, EFP decoding performed comparably to ECoG decoding. The 7-20 Hz and 70-115 Hz spectral bands contained the most information about grasp kinematics, with the 70-115 Hz band containing greater information about more subtle movements. Higher-resolution recording arrays provided clearly superior performance compared to standard-resolution arrays. Significance. To approach the fine motor control achieved by an intact brain-body system, it will be necessary to execute motor intent on a continuous basis with high accuracy. The current results demonstrate that this level of accuracy might be achievable not just with ECoG, but with EFPs as well. Epidural placement of electrodes is less invasive, and therefore may incur less risk of encephalitis or stroke than subdural placement of electrodes. Accurately decoding motor commands at the epidural level may be an important step towards a clinically viable brain-machine interface.
Continuous decoding of human grasp kinematics using epidural and subdural signals
Flint, Robert D.; Rosenow, Joshua M.; Tate, Matthew C.; Slutzky, Marc W.
2017-01-01
Objective Restoring or replacing function in paralyzed individuals will one day be achieved through the use of brain-machine interfaces (BMIs). Regaining hand function is a major goal for paralyzed patients. Two competing prerequisites for the widespread adoption of any hand neuroprosthesis are: accurate control over the fine details of movement, and minimized invasiveness. Here, we explore the interplay between these two goals by comparing our ability to decode hand movements with subdural and epidural field potentials. Approach We measured the accuracy of decoding continuous hand and finger kinematics during naturalistic grasping motions in five human subjects. We recorded subdural surface potentials (electrocorticography; ECoG) as well as with epidural field potentials (EFPs), with both standard- and high-resolution electrode arrays. Main results In all five subjects, decoding of continuous kinematics significantly exceeded chance, using either EGoG or EFPs. ECoG decoding accuracy compared favorably with prior investigations of grasp kinematics (mean± SD grasp aperture variance accounted for was 0.54± 0.05 across all subjects, 0.75± 0.09 for the best subject). In general, EFP decoding performed comparably to ECoG decoding. The 7–20 Hz and 70–115 Hz spectral bands contained the most information about grasp kinematics, with the 70–115 Hz band containing greater information about more subtle movements. Higher-resolution recording arrays provided clearly superior performance compared to standard-resolution arrays. Significance To approach the fine motor control achieved by an intact brain-body system, it will be necessary to execute motor intent on a continuous basis with high accuracy. The current results demonstrate that this level of accuracy might be achievable not just with ECoG, but with EFPs as well. Epidural placement of electrodes is less invasive, and therefore may incur less risk of encephalitis or stroke than subdural placement of electrodes. Accurately decoding motor commands at the epidural level may be an important step towards a clinically viable brain-machine interface. PMID:27900947
Electrotactile Feedback Improves Performance and Facilitates Learning in the Routine Grasping Task.
Isaković, Milica; Belić, Minja; Štrbac, Matija; Popović, Igor; Došen, Strahinja; Farina, Dario; Keller, Thierry
2016-06-13
Aim of this study was to investigate the feasibility of electrotactile feedback in closed loop training of force control during the routine grasping task. The feedback was provided using an array electrode and a simple six-level spatial coding, and the experiment was conducted in three amputee subjects. The psychometric tests confirmed that the subjects could perceive and interpret the electrotactile feedback with a high success rate. The subjects performed the routine grasping task comprising 4 blocks of 60 grasping trials. In each trial, the subjects employed feedforward control to close the hand and produce the desired grasping force (four levels). First (baseline) and the last (validation) session were performed in open loop, while the second and the third session (training) included electrotactile feedback. The obtained results confirmed that using the feedback improved the accuracy and precision of the force control. In addition, the subjects performed significantly better in the validation vs. baseline session, therefore suggesting that electrotactile feedback can be used for learning and training of myoelectric control.
Evidence for right-hand feeding biases in a left-handed population.
Flindall, Jason W; Stone, Kayla D; Gonzalez, Claudia L R
2015-05-01
We have recently shown that actions with similar kinematic requirements, but different end-state goals may be supported by distinct neural networks. Specifically, we demonstrated that when right-handed individuals reach-to-grasp food items with intent to eat, they produce smaller maximum grip apertures (MGAs) than when they grasp the same item with intent to place it in a location near the mouth. This effect was restricted to right-handed movements; left-handed movements showed no difference between tasks. The current study investigates whether (and to which side) the effect may be lateralized in left-handed individuals. Twenty-one self-identified left-handed participants grasped food items of three different sizes while grasp kinematics were captured via an Optotrak Certus motion capture array. A main effect of task was identified wherein the grasp-to-eat action generated significantly smaller MGAs than did the grasp-to-place action. Further analysis revealed that similar to the findings in right-handed individuals, this effect was significant only during right-handed movements. Upon further inspection however, we found individual differences in the magnitude and direction of the observed lateralization. These results underscore the evolutionary significance of the grasp-to-eat movement in producing population-level right-handedness in humans as well as highlighting the heterogeneity of the left-handed population.
Hook, Sharon E; Skillman, Ann D; Small, Jack A; Schultz, Irvin R
2006-07-01
Determining how gene expression profiles change with toxicant dose will improve the utility of arrays in identifying biomarkers and modes of toxic action. Isogenic rainbow trout, Oncorhyncus mykiss,were exposed to 10, 50 or 100 ng/L ethynylestradiol (a xeno-estrogen) for 7 days. Following exposure hepatic RNA was extracted. Fluorescently labeled cDNA were generated and hybridized against a commercially available Atlantic Salmon/Trout array (GRASP project, University of Victoria) spotted with 16,000 cDNAs. Transcript expression in treated vs control fish was analyzed via Genespring (Silicon Genetics) to identify genes with altered expression, as well as to determine gene clustering patterns that can be used as "expression signatures". Array results were confirmed via qRT PCR. Our analysis indicates that gene expression profiles varied somewhat with dose. Established biomarkers of exposure to estrogenic chemicals, such as vitellogenin, vitelline envelope proteins, and the estrogen receptor alpha, were induced at every dose. Other genes were dose specific, suggesting that different doses induce distinct physiological responses. These findings demonstrate that cDNA microarrays could be used to identify both toxicant class and relative dose.
Benkert, Thomas; Tian, Ye; Huang, Chenchan; DiBella, Edward V R; Chandarana, Hersh; Feng, Li
2018-07-01
Golden-angle radial sparse parallel (GRASP) MRI reconstruction requires gridding and regridding to transform data between radial and Cartesian k-space. These operations are repeatedly performed in each iteration, which makes the reconstruction computationally demanding. This work aimed to accelerate GRASP reconstruction using self-calibrating GRAPPA operator gridding (GROG) and to validate its performance in clinical imaging. GROG is an alternative gridding approach based on parallel imaging, in which k-space data acquired on a non-Cartesian grid are shifted onto a Cartesian k-space grid using information from multicoil arrays. For iterative non-Cartesian image reconstruction, GROG is performed only once as a preprocessing step. Therefore, the subsequent iterative reconstruction can be performed directly in Cartesian space, which significantly reduces computational burden. Here, a framework combining GROG with GRASP (GROG-GRASP) is first optimized and then compared with standard GRASP reconstruction in 22 prostate patients. GROG-GRASP achieved approximately 4.2-fold reduction in reconstruction time compared with GRASP (∼333 min versus ∼78 min) while maintaining image quality (structural similarity index ≈ 0.97 and root mean square error ≈ 0.007). Visual image quality assessment by two experienced radiologists did not show significant differences between the two reconstruction schemes. With a graphics processing unit implementation, image reconstruction time can be further reduced to approximately 14 min. The GRASP reconstruction can be substantially accelerated using GROG. This framework is promising toward broader clinical application of GRASP and other iterative non-Cartesian reconstruction methods. Magn Reson Med 80:286-293, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Hook, Sharon E.; Skillman, Ann D.; Small, Jack A.; Schultz, Irvin R.
2008-01-01
Determining how gene expression profiles change with toxicant dose will improve the utility of arrays in identifying biomarkers and modes of toxic action. Isogenic rainbow trout, Oncorhyncus mykiss, were exposed to 10, 50 or 100 ng/L ethynylestradiol (a xeno-estrogen) for 7 days. Following exposure hepatic RNA was extracted. Fluorescently labeled cDNA were generated and hybridized against a commercially available Atlantic Salmon/Trout array (GRASP project, University of Victoria) spotted with 16,000 cDNAs. Transcript expression in treated vs control fish was analyzed via Genespring (Silicon Genetics) to identify genes with altered expression, as well as to determine gene clustering patterns that can be used as “expression signatures”. Array results were confirmed via qRT PCR. Our analysis indicates that gene expression profiles varied somewhat with dose. Established biomarkers of exposure to estrogenic chemicals, such as vitellogenin, vitelline envelope proteins, and the estrogen receptor alpha, were induced at every dose. Other genes were dose specific, suggesting that diffierent doses induce distinct physiological responses. These findings demonstrate that cDNA microarrays could be used to identify both toxicant class and relative dose. PMID:16725192
Encoding of Both Reaching and Grasping Kinematics in Dorsal and Ventral Premotor Cortices
Best, Matthew D.
2017-01-01
Classically, it has been hypothesized that reach-to-grasp movements arise from two discrete parietofrontal cortical networks. As part of these networks, the dorsal premotor cortex (PMd) has been implicated in the control of reaching movements of the arm, whereas the ventral premotor cortex (PMv) has been associated with the control of grasping movements of the hand. Recent studies have shown that such a strict delineation of function along anatomical boundaries is unlikely, partly because reaching to different locations can alter distal hand kinematics and grasping different objects can affect kinematics of the proximal arm. Here, we used chronically implanted multielectrode arrays to record unit-spiking activity in both PMd and PMv simultaneously while rhesus macaques engaged in a reach-to-grasp task. Generalized linear models were used to predict the spiking activity of cells in both areas as a function of different kinematic parameters, as well as spike history. To account for the influence of reaching on hand kinematics and vice versa, we applied demixed principal components analysis to define kinematics synergies that maximized variance across either different object locations or grip types. We found that single cells in both PMd and PMv encode the kinematics of both reaching and grasping synergies, suggesting that this classical division of reach and grasp in PMd and PMv, respectively, does not accurately reflect the encoding preferences of cells in those areas. SIGNIFICANCE STATEMENT For reach-to-grasp movements, the dorsal premotor cortex (PMd) has been implicated in the control of reaching movements of the arm, whereas the ventral premotor cortex (PMv) has been associated with the control of grasping movements of the hand. We recorded unit-spiking activity in PMd and PMv simultaneously while macaques performed a reach-to-grasp task. We modeled the spiking activity of neurons as a function of kinematic parameters and spike history. We applied demixed principal components analysis to define kinematics synergies. We found that single units in both PMd and PMv encode the kinematics of both reaching and grasping synergies, suggesting that the division of reach and grasp in PMd and PMv, respectively, cannot be made based on their encoding properties. PMID:28077725
NASA Technical Reports Server (NTRS)
Stutzman, W. L.; Takamizawa, K.; Werntz, P.; Lapean, J.; Barts, R.
1991-01-01
The following subject areas are covered: General Reflector Antenna Systems Program version 7(GRASP7); Multiple Reflector Analysis Program for Cylindrical Antennas (MRAPCA); Tri-Reflector 2D Synthesis Code (TRTDS); a geometrical optics and a physical optics synthesis techniques; beam scanning reflector, the type 2 and 6 reflectors, spherical reflector, and multiple reflector imaging systems; and radiometric array design.
Thomas, Brittany L; Karl, Jenni M; Whishaw, Ian Q
2014-01-01
The Dual Visuomotor Channel Theory proposes that visually guided reaching is a composite of two movements, a Reach that advances the hand to contact the target and a Grasp that shapes the digits for target purchase. The theory is supported by biometric analyses of adult reaching, evolutionary contrasts, and differential developmental patterns for the Reach and the Grasp in visually guided reaching in human infants. The present ethological study asked whether there is evidence for a dissociated development for the Reach and the Grasp in nonvisual hand use in very early infancy. The study documents a rich array of spontaneous self-touching behavior in infants during the first 6 months of life and subjected the Reach movements to an analysis in relation to body target, contact type, and Grasp. Video recordings were made of resting alert infants biweekly from birth to 6 months. In younger infants, self-touching targets included the head and trunk. As infants aged, targets became more caudal and included the hips, then legs, and eventually the feet. In younger infants hand contact was mainly made with the dorsum of the hand, but as infants aged, contacts included palmar contacts and eventually grasp and manipulation contacts with the body and clothes. The relative incidence of caudal contacts and palmar contacts increased concurrently and were significantly correlated throughout the period of study. Developmental increases in self-grasping contacts occurred a few weeks after the increase in caudal and palmar contacts. The behavioral and temporal pattern of these spontaneous self-touching movements suggest that the Reach, in which the hand extends to make a palmar self-contact, and the Grasp, in which the digits close and make manipulatory movements, have partially independent developmental profiles. The results additionally suggest that self-touching behavior is an important developmental phase that allows the coordination of the Reach and the Grasp prior to and concurrent with their use under visual guidance.
Spiers, Adam J; Liarokapis, Minas V; Calli, Berk; Dollar, Aaron M
2016-01-01
Classical robotic approaches to tactile object identification often involve rigid mechanical grippers, dense sensor arrays, and exploratory procedures (EPs). Though EPs are a natural method for humans to acquire object information, evidence also exists for meaningful tactile property inference from brief, non-exploratory motions (a 'haptic glance'). In this work, we implement tactile object identification and feature extraction techniques on data acquired during a single, unplanned grasp with a simple, underactuated robot hand equipped with inexpensive barometric pressure sensors. Our methodology utilizes two cooperating schemes based on an advanced machine learning technique (random forests) and parametric methods that estimate object properties. The available data is limited to actuator positions (one per two link finger) and force sensors values (eight per finger). The schemes are able to work both independently and collaboratively, depending on the task scenario. When collaborating, the results of each method contribute to the other, improving the overall result in a synergistic fashion. Unlike prior work, the proposed approach does not require object exploration, re-grasping, grasp-release, or force modulation and works for arbitrary object start positions and orientations. Due to these factors, the technique may be integrated into practical robotic grasping scenarios without adding time or manipulation overheads.
Temporal Changes in Gene Expression in Rainbow Trout Exposed to Ethynyl Estradiol*
Skillman, Ann D.; Small, Jack A.; Schultz, Irvin R.
2007-01-01
We examined changes in the genomic response during continuous exposure to the xenoestrogen ethynylestradiol. Isogenic rainbow trout Oncorhynchus mykiss were exposed to nominal concentrations of 100 ng/L ethynyl estradiol (EE2) for a period of three weeks. At fixed time points within the exposure, fish were euthanized, livers harvested and RNA extracted. Fluorescently labeled cDNA were generated and hybridized against a commercially available Salmonid array (GRASP project, University of Victoria, Canada) spotted with 16,000 cDNAs. The slides were scanned to measure abundance of a given transcript in each sample relative to controls. Data were analyzed via Genespring (Silicon Genetics) to identify a list of up and down regulated genes, and to determine gene clustering patterns that can be used as “expression signatures”. Gene ontology was determined using the annotation available from the GRASP website. Our analysis indicates each exposure time period generated specific gene expression profiles. Changes in gene expression were best understood by grouping genes by their gene expression profiles rather than examining fold change at a particular time point. Many of the genes commonly used as biomarkers of exposure to xenoestrogens were not induced initially and did not have gene expression profiles typical of the majority of genes with altered expression. PMID:17215170
Temporal changes in gene expression in rainbow trout exposed to ethynyl estradiol.
Hook, Sharon E; Skillman, Ann D; Small, Jack A; Schultz, Irvin R
2007-02-01
We examined changes in the genomic response during continuous exposure to the xenoestrogen ethynyl estradiol. Isogenic rainbow trout Oncorhynchus mykiss were exposed to nominal concentrations of 100 ng/L ethynyl estradiol (EE2) for a period of 3 weeks. At fixed time points within the exposure, fish were euthanized, livers harvested and RNA extracted. Fluorescently labeled cDNA were generated and hybridized against a commercially available Salmonid array (GRASP project, University of Victoria, Canada) spotted with 16,000 cDNAs. The slides were scanned to measure abundance of a given transcript in each sample relative to controls. Data were analyzed via Genespring (Silicon Genetics) to identify a list of up and down regulated genes, and to determine gene clustering patterns that can be used as "expression signatures". Gene ontology was determined using the annotation available from the GRASP website. Our analysis indicates each exposure time period generated specific gene expression profiles. Changes in gene expression were best understood by grouping genes by their gene expression profiles rather than examining fold change at a particular time point. Many of the genes commonly used as biomarkers of exposure to xenoestrogens were not induced initially and did not have gene expression profiles typical of the majority of genes with altered expression.
NASA Technical Reports Server (NTRS)
Primus, H. C.
1986-01-01
Touch sensor for robot hands provides information about shape of grasped object and force exerted by gripper on object. Pins projecting from sensor create electrical signals when pressed. When grasped object depresses pin, it contacts electrode under it, connecting electrode to common electrode. Sensor indicates where, and how firmly, gripper has touched object.
Making rainfall features fun: scientific activities for teaching children aged 5-12 years
NASA Astrophysics Data System (ADS)
Gires, Auguste; Muller, Catherine L.; le Gueut, Marie-Agathe; Schertzer, Daniel
2016-05-01
Research projects now rely on an array of different channels to increase impact, including high-level scientific output, tools, and equipment, but also communication, outreach, and educational activities. This paper focuses on education for children aged 5-12 years and presents activities that aim to help them (and their teachers) grasp some of the complex underlying issues in environmental science. More generally, it helps children to become familiarized with science and scientists, with the aim to enhance scientific culture and promote careers in this field. The activities developed are focused on rainfall: (a) designing and using a disdrometer to observe the variety of drop sizes; (b) careful recording of successive dry and rainy days and reproducing patterns using a simple model based on fractal random multiplicative cascades; and (c) collaboratively writing a children's book about rainfall. These activities are discussed in the context of current state-of-the-art pedagogical practices and goals set by project funders, especially in a European Union framework.
Grasping trajectories in a virtual environment adhere to Weber's law.
Ozana, Aviad; Berman, Sigal; Ganel, Tzvi
2018-06-01
Virtual-reality and telerobotic devices simulate local motor control of virtual objects within computerized environments. Here, we explored grasping kinematics within a virtual environment and tested whether, as in normal 3D grasping, trajectories in the virtual environment are performed analytically, violating Weber's law with respect to object's size. Participants were asked to grasp a series of 2D objects using a haptic system, which projected their movements to a virtual space presented on a computer screen. The apparatus also provided object-specific haptic information upon "touching" the edges of the virtual targets. The results showed that grasping movements performed within the virtual environment did not produce the typical analytical trajectory pattern obtained during 3D grasping. Unlike as in 3D grasping, grasping trajectories in the virtual environment adhered to Weber's law, which indicates relative resolution in size processing. In addition, the trajectory patterns differed from typical trajectories obtained during 3D grasping, with longer times to complete the movement, and with maximum grip apertures appearing relatively early in the movement. The results suggest that grasping movements within a virtual environment could differ from those performed in real space, and are subjected to irrelevant effects of perceptual information. Such atypical pattern of visuomotor control may be mediated by the lack of complete transparency between the interface and the virtual environment in terms of the provided visual and haptic feedback. Possible implications of the findings to movement control within robotic and virtual environments are further discussed.
Niu, Xun; Latash, Mark L.; Zatsiorsky, Vladimir M.
2010-01-01
We studied adjustments of digit forces to changes in the friction. The subjects held a handle statically in a three-digit grasp. The friction under each digit was either high or low, resulting in eight three-element friction sets (such grasps were coined the grasps with complex friction pattern). The total load was also manipulated. It was found that digit forces were adjusted not only to the supported load and local friction, but also to friction at other digits (synergic effects). When friction under a digit was low, its tangential force decreased and the normal force increased (local effects). The synergic effects were directed to maintain the equilibrium of the handle. The relation between the individual digit forces and loads agreed with the triple-product model: fin=ki(2)ki(1)L, where fin is normal force of digit i, L is the load (newtons), ki(1) is a dimensionless coefficient representing sharing the total tangential force among the digits (Σki(1)=1.0), and ki(2) is a coefficient representing the relation between the tangential and normal forces of digit i (the overall friction equivalent, OFE). At each friction set, the central controller selected the grasping template—a three-element array of ki(2)ki(1) products—and then scaled the template with the load magnitude. PMID:17493928
NASA Astrophysics Data System (ADS)
Dochartaigh, B. É. Ó.; Fordyce, F. M.; Ander, E. L.; Bonsor, H. C.
2009-04-01
The protection of groundwater and related surface water quality is a key aspect of the European Union Water Framework Directive and environmental legislation in many countries worldwide. Globally, the protection of urban groundwater resources and related ecosystem services is of growing concern as urbanisation increases. Although urban areas are often where groundwater resources are most in need of protection, there is frequently a lack of information about threats to groundwater quality. Most studies of soil and groundwater contamination, although detailed, are site-specific, and city-wide overviews are generally lacking. The British Geological Survey (BGS) is currently undertaking the Clyde Urban Super-Project (CUSP), delivering multi-disciplinary geoscience products for the Glasgow conurbation. Under this project, a GIS-based prioritisation tool known as GRASP (GRoundwater And Soil Pollutants) has been trialled to aid urban planning and sustainable development by providing a broad-scale assessment of threats to groundwater quality across the conurbation. GRASP identifies areas where shallow groundwater quality is at greatest threat from the leaching and downward movement of potentially harmful metals in the soil. Metal contamination is a known problem in many urban centres including Glasgow, which has a long industrial heritage and associated contamination legacy, notably with respect to Cr. GRASP is based primarily upon an existing British Standard - International Standards Organisation methodology to determine the leaching potential of metals from soils, which has been validated for 11 metals: Al, Fe, Cd, Co, Cr, Cu, Hg, Ni, Mn, Pb and Zn (BS-ISO 15175:2004). However, the GRASP tool is innovative as it combines assessments of soil leaching potential with soil metal content data to highlight threats to shallow groundwater quality. The input parameters required for GRASP (soil pH, clay, organic matter, sesquioxide and metal content) are based upon a systematic geochemical dataset of 1600 soils (4 per km2) collected across Glasgow as part of the BGS Geochemical Baseline Survey of the Environment (G-BASE) project. These parameters are combined with assessments of climate, groundwater levels and the leaching potential of unsaturated Quaternary deposits to produce maps that prioritise the likely threats to shallow groundwater quality. Data processing for the GRASP methodology is carried out in five steps in Microsoft Excel®, using Visual Basic® programming language, and ArcGIS® software. The GRASP prioritisation tool is in the process of development; however, the rationale and initial derivation of the methodology for the city of Glasgow will be presented.
Compact Tactile Sensors for Robot Fingers
NASA Technical Reports Server (NTRS)
Martin, Toby B.; Lussy, David; Gaudiano, Frank; Hulse, Aaron; Diftler, Myron A.; Rodriguez, Dagoberto; Bielski, Paul; Butzer, Melisa
2004-01-01
Compact transducer arrays that measure spatial distributions of force or pressure have been demonstrated as prototypes of tactile sensors to be mounted on fingers and palms of dexterous robot hands. The pressure- or force-distribution feedback provided by these sensors is essential for the further development and implementation of robot-control capabilities for humanlike grasping and manipulation.
Bio-inspired grasp control in a robotic hand with massive sensorial input.
Ascari, Luca; Bertocchi, Ulisse; Corradi, Paolo; Laschi, Cecilia; Dario, Paolo
2009-02-01
The capability of grasping and lifting an object in a suitable, stable and controlled way is an outstanding feature for a robot, and thus far, one of the major problems to be solved in robotics. No robotic tools able to perform an advanced control of the grasp as, for instance, the human hand does, have been demonstrated to date. Due to its capital importance in science and in many applications, namely from biomedics to manufacturing, the issue has been matter of deep scientific investigations in both the field of neurophysiology and robotics. While the former is contributing with a profound understanding of the dynamics of real-time control of the slippage and grasp force in the human hand, the latter tries more and more to reproduce, or take inspiration by, the nature's approach, by means of hardware and software technology. On this regard, one of the major constraints robotics has to overcome is the real-time processing of a large amounts of data generated by the tactile sensors while grasping, which poses serious problems to the available computational power. In this paper a bio-inspired approach to tactile data processing has been followed in order to design and test a hardware-software robotic architecture that works on the parallel processing of a large amount of tactile sensing signals. The working principle of the architecture bases on the cellular nonlinear/neural network (CNN) paradigm, while using both hand shape and spatial-temporal features obtained from an array of microfabricated force sensors, in order to control the sensory-motor coordination of the robotic system. Prototypical grasping tasks were selected to measure the system performances applied to a computer-interfaced robotic hand. Successful grasps of several objects, completely unknown to the robot, e.g. soft and deformable objects like plastic bottles, soft balls, and Japanese tofu, have been demonstrated.
Software engineering capability for Ada (GRASP/Ada Tool)
NASA Technical Reports Server (NTRS)
Cross, James H., II
1995-01-01
The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) has successfully created and prototyped a new algorithmic level graphical representation for Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis has been on the automatic generation of the CSD from Ada PDL or source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional prettyprinted Ada Source code. A new Motif compliant graphical user interface has been developed for the GRASP/Ada prototype.
Appreciating the Complexity of Project Management Execution: Using Simulation in the Classroom
ERIC Educational Resources Information Center
Hartman, Nathan S.; Watts, Charles A.; Treleven, Mark D.
2013-01-01
As the popularity and importance of project management increase, so does the need for well-prepared project managers. This article discusses our experiences using a project management simulation in undergraduate and MBA classes to help students better grasp the complexity of project management. This approach gives students hands-on experience with…
Rouse, Adam G.
2016-01-01
In reaching to grasp an object, proximal muscles that act on the shoulder and elbow classically have been viewed as transporting the hand to the intended location, while distal muscles that act on the fingers simultaneously shape the hand to grasp the object. Prior studies of electromyographic (EMG) activity in upper extremity muscles therefore have focused, by and large, either on proximal muscle activity during reaching to different locations or on distal muscle activity as the subject grasps various objects. Here, we examined the EMG activity of muscles from the shoulder to the hand, as monkeys reached and grasped in a task that dissociated location and object. We quantified the extent to which variation in the EMG activity of each muscle depended on location, on object, and on their interaction—all as a function of time. Although EMG variation depended on both location and object beginning early in the movement, an early phase of substantial location effects in muscles from proximal to distal was followed by a later phase in which object effects predominated throughout the extremity. Interaction effects remained relatively small. Our findings indicate that neural control of reach-to-grasp may occur largely in two sequential phases: the first, serving to project the entire upper extremity toward the intended location, and the second, acting predominantly to shape the entire extremity for grasping the object. PMID:27009156
Rouse, Adam G.
2016-01-01
Reaching and grasping typically are considered to be spatially separate processes that proceed concurrently in the arm and the hand, respectively. The proximal representation in the primary motor cortex (M1) controls the arm for reaching, while the distal representation controls the hand for grasping. Many studies of M1 activity therefore have focused either on reaching to various locations without grasping different objects, or else on grasping different objects all at the same location. Here, we recorded M1 neurons in the anterior bank and lip of the central sulcus as monkeys performed more naturalistic movements, reaching toward, grasping, and manipulating four different objects in up to eight different locations. We quantified the extent to which variation in firing rates depended on location, on object, and on their interaction—all as a function of time. Activity proceeded largely in two sequential phases: the first related predominantly to the location to which the upper extremity reached, and the second related to the object about to be grasped. Both phases involved activity distributed widely throughout the sampled territory, spanning both the proximal and the distal upper extremity representation in caudal M1. Our findings indicate that naturalistic reaching and grasping, rather than being spatially segregated processes that proceed concurrently, each are spatially distributed processes controlled by caudal M1 in large part sequentially. Rather than neuromuscular processes separated in space but not time, reaching and grasping are separated more in time than in space. SIGNIFICANCE STATEMENT Reaching and grasping typically are viewed as processes that proceed concurrently in the arm and hand, respectively. The arm region in the primary motor cortex (M1) is assumed to control reaching, while the hand region controls grasping. During naturalistic reach–grasp–manipulate movements, we found, however, that neuron activity proceeds largely in two sequential phases, each spanning both arm and hand representations in M1. The first phase is related predominantly to the reach location, and the second is related to the object about to be grasped. Our findings indicate that reaching and grasping are successive aspects of a single movement. Initially the arm and the hand both are projected toward the object's location, and later both are shaped to grasp and manipulate. PMID:27733614
NASA Astrophysics Data System (ADS)
Hallar, A. G.; McCubbin, I. B.; Hallar, B. L.; Stockwell, W.; Kittelson, J.; Lopez, J.
2008-12-01
Geoscience Research at Storm Peak (GRASP) was designed to engage students from underrepresented groups through a partnership between Minority Serving Institutions and the University of Nevada, Reno (UNR). The program exposed the GRASP participants to potential careers in the geosciences, provided them with an authentic research experience at Storm Peak Laboratory (SPL), and gave them an opportunity to explore dynamic scenery. Undergraduate students from Howard University, Colorado State at Pueblo, Leman College, and SUNY Oneonta, gathered at SPL in June of 2008 via funding from the National Science Foundation Opportunity for Enhancing Diversity. The students reunited at Howard University in November to present the results of their research project. Throughout the year-long GRASP program students encountered the scientific process-creating a hypothesis, collecting and analyzing data, and presenting their results. Results from surveys, focus groups, and individual interviews will be discussed in this presentation.
Linear and nonlinear subspace analysis of hand movements during grasping.
Cui, Phil Hengjun; Visell, Yon
2014-01-01
This study investigated nonlinear patterns of coordination, or synergies, underlying whole-hand grasping kinematics. Prior research has shed considerable light on roles played by such coordinated degrees-of-freedom (DOF), illuminating how motor control is facilitated by structural and functional specializations in the brain, peripheral nervous system, and musculoskeletal system. However, existing analyses suppose that the patterns of coordination can be captured by means of linear analyses, as linear combinations of nominally independent DOF. In contrast, hand kinematics is itself highly nonlinear in nature. To address this discrepancy, we sought to to determine whether nonlinear synergies might serve to more accurately and efficiently explain human grasping kinematics than is possible with linear analyses. We analyzed motion capture data acquired from the hands of individuals as they grasped an array of common objects, using four of the most widely used linear and nonlinear dimensionality reduction algorithms. We compared the results using a recently developed algorithm-agnostic quality measure, which enabled us to assess the quality of the dimensional reductions that resulted by assessing the extent to which local neighborhood information in the data was preserved. Although qualitative inspection of this data suggested that nonlinear correlations between kinematic variables were present, we found that linear modeling, in the form of Principle Components Analysis, could perform better than any of the nonlinear techniques we applied.
Decoding a wide range of hand configurations from macaque motor, premotor, and parietal cortices.
Schaffelhofer, Stefan; Agudelo-Toro, Andres; Scherberger, Hansjörg
2015-01-21
Despite recent advances in decoding cortical activity for motor control, the development of hand prosthetics remains a major challenge. To reduce the complexity of such applications, higher cortical areas that also represent motor plans rather than just the individual movements might be advantageous. We investigated the decoding of many grip types using spiking activity from the anterior intraparietal (AIP), ventral premotor (F5), and primary motor (M1) cortices. Two rhesus monkeys were trained to grasp 50 objects in a delayed task while hand kinematics and spiking activity from six implanted electrode arrays (total of 192 electrodes) were recorded. Offline, we determined 20 grip types from the kinematic data and decoded these hand configurations and the grasped objects with a simple Bayesian classifier. When decoding from AIP, F5, and M1 combined, the mean accuracy was 50% (using planning activity) and 62% (during motor execution) for predicting the 50 objects (chance level, 2%) and substantially larger when predicting the 20 grip types (planning, 74%; execution, 86%; chance level, 5%). When decoding from individual arrays, objects and grip types could be predicted well during movement planning from AIP (medial array) and F5 (lateral array), whereas M1 predictions were poor. In contrast, predictions during movement execution were best from M1, whereas F5 performed only slightly worse. These results demonstrate for the first time that a large number of grip types can be decoded from higher cortical areas during movement preparation and execution, which could be relevant for future neuroprosthetic devices that decode motor plans. Copyright © 2015 the authors 0270-6474/15/351068-14$15.00/0.
Working and Learning with Knowledge in the Lobes of a Humanoid's Mind
NASA Technical Reports Server (NTRS)
Ambrose, Robert; Savely, Robert; Bluethmann, William; Kortenkamp, David
2003-01-01
Humanoid class robots must have sufficient dexterity to assist people and work in an environment designed for human comfort and productivity. This dexterity, in particular the ability to use tools, requires a cognitive understanding of self and the world that exceeds contemporary robotics. Our hypothesis is that the sense-think-act paradigm that has proven so successful for autonomous robots is missing one or more key elements that will be needed for humanoids to meet their full potential as autonomous human assistants. This key ingredient is knowledge. The presented work includes experiments conducted on the Robonaut system, a NASA and the Defense Advanced research Projects Agency (DARPA) joint project, and includes collaborative efforts with a DARPA Mobile Autonomous Robot Software technical program team of researchers at NASA, MIT, USC, NRL, UMass and Vanderbilt. The paper reports on results in the areas of human-robot interaction (human tracking, gesture recognition, natural language, supervised control), perception (stereo vision, object identification, object pose estimation), autonomous grasping (tactile sensing, grasp reflex, grasp stability) and learning (human instruction, task level sequences, and sensorimotor association).
There Must Be A-Way (to Deal with Solid Waste).
ERIC Educational Resources Information Center
Fortner, Rosanne W.
1991-01-01
Presents a class project to help upper elementary students grasp the extent of the solid waste disposal problem and develop an individual response. Includes background information for the teacher, project objectives, materials, procedures, and a listing for additional resources. (MCO)
Exploring the Occurrence of Team Learning Behaviours in Project Teams over Time
ERIC Educational Resources Information Center
Raes, Elisabeth; Boon, Anne; Kyndt, Eva; Dochy, Filip
2017-01-01
The aim of this qualitative longitudinal study is to create a more in-depth picture of the emergence of team learning behaviours throughout the lifespan of temporary project teams. In order to grasp the emergence of these behaviours, three project teams were followed from the start until the end of their project during a period of three months.…
Nanoracks CUBESAT launcher operations
2014-08-19
ISS040-E-102490 (19 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer releases a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at left.
2014-08-20
ISS040-E-102420 (20 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer releases a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at left.
2014-08-20
ISS040-E-102425 (20 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer releases a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at left.
2014-08-20
ISS040-E-102410 (20 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer is about to release a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at left.
ERIC Educational Resources Information Center
Toh, Chee-Seng
2007-01-01
A project is described which incorporates nonlaboratory research skills in a graduate level course on analytical chemistry. This project will help students to grasp the basic principles and concepts of modern analytical techniques and also help them develop relevant research skills in analytical chemistry.
NASA Astrophysics Data System (ADS)
Johansson, Emma; Lindborg, Tobias
2017-04-01
The Arctic region is sensitive to global warming, and permafrost thaw and release of old carbon are examples of processes that may have a positive feedback effect to the global climate system. Quantification and assumptions on future change are often based on model predictions. Such models require cross-disciplinary data of high quality that often is lacking. Biogeochemical processes in the landscape are highly influenced by the hydrology, which in turn is intimately related to permafrost processes. Thus, a multidisciplinary approach is needed when collecting data and setting up field experiments aiming at increase the understanding of these processes. Here we summarize and present data collected in the GRASP, Greenland Analogue Surface Project. GRASP is a catchment-scale field study of the periglacial area in the Kangerlussuaq region, West Greenland, focusing on hydrological and biogeochemical processes in the landscape. The site investigations were initiated in 2010 and have since then resulted in three separate data sets published in ESSD (Earth system and Science Data) each one focusing on i) meteorological data and hydrology, ii) biogeochemistry and iii) geometries of sediments and the active layer. The three data-sets, which are freely available via the PANGAEA data base, enable conceptual and coupled numerical modeling of hydrological and biogeochemical processes. An important strength with the GRASP data is that all data is collected within the same, relatively small, catchment area. This implies that measurements are more easily linked to the right source area or process. Despite the small catchment area it includes the major units of the periglacial hydrological system; a lake, a talik, a supra- and subpermafrost aquifer and, consequently, biogeochemical processes in each of these units may be studied. The new data from GRASP is both used with the aim to increase the knowledge of present day periglacial hydrology and biogeochemistry but also in order to predict consequences within these subjects of future climate change.
Hubble Space Telescope Deploy, Cuba, Bahamas and Gulf of Mexico
1990-04-29
STS031-151-010 (25 April 1990) --- The Hubble Space Telescope (HST), still in the grasp of Discovery's Remote Manipulator System (RMS), is backdropped over Cuba and the Bahama Islands. In this scene, it has yet to have deployment of its solar array panels and its high gain antennae. This scene was captured with a large format Aero Linhof camera used by several previous flight crews to record Earth scenes.
The Navajo Agricultural Projects Industry: Subsistence Farming to Corporate Agribusiness.
ERIC Educational Resources Information Center
Barry, Tom
1979-01-01
Originally designed to create small farms for individual Navajos, the irrigation project has grown into a single 110,000-acre corporate agribusiness, the land's management has fallen out of the grasp of individual Navajos, and the idea of subsistence farming has been plowed under for the planting of major money-making crops. (NQ)
ERIC Educational Resources Information Center
Shibahara, Rika
2017-01-01
This study examines Malaysian learners' reflections on the discourses of the Asia-Pacific War in Malaysia and Japan after engaging in "Memories of War" project. The project, which was implemented in an advanced Japanese-as-a-Foreign-Language (JFL) class at a Malaysian university, aimed to improve learners' ability to grasp power…
Update of GRASP/Ada reverse engineering tools for Ada
NASA Technical Reports Server (NTRS)
Cross, James H., II
1993-01-01
The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) successfully created and prototyped a new algorithmic level graphical representation for Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis was on the automatic generation of the CSD from Ada PDL or source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional pretty printed Ada source code. In Phase 1 of the GRASP/Ada project, the CSD graphical constructs were created and applied manually to several small Ada programs. A prototype CSD generator (Version 1) was designed and implemented using FLEX and BISON running under VMS on a VAX 11-780. In Phase 2, the prototype was improved and ported to the Sun 4 platform under UNIX. A user interface was designed and partially implemented using the HP widget toolkit and the X Windows System. In Phase 3, the user interface was extensively reworked using the Athena widget toolkit and X Windows. The prototype was applied successfully to numerous Ada programs ranging in size from several hundred to several thousand lines of source code. Following Phase 3,e two update phases were completed. Update'92 focused on the initial analysis of evaluation data collected from software engineering students at Auburn University and the addition of significant enhancements to the user interface. Update'93 (the current update) focused on the statistical analysis of the data collected in the previous update and preparation of Version 3.4 of the prototype for limited distribution to facilitate further evaluation. The current prototype provides the capability for the user to generate CSD's from Ada PDL or source code in a reverse engineering as well as forward engineering mode with a level of flexibility suitable for practical application. An overview of the GRASP/Ada project with an emphasis on the current update is provided.
Bansal, Arjun K; Truccolo, Wilson; Vargas-Irwin, Carlos E; Donoghue, John P
2012-03-01
Neural activity in motor cortex during reach and grasp movements shows modulations in a broad range of signals from single-neuron spiking activity (SA) to various frequency bands in broadband local field potentials (LFPs). In particular, spatiotemporal patterns in multiband LFPs are thought to reflect dendritic integration of local and interareal synaptic inputs, attentional and preparatory processes, and multiunit activity (MUA) related to movement representation in the local motor area. Nevertheless, the relationship between multiband LFPs and SA, and their relationship to movement parameters and their relative value as brain-computer interface (BCI) control signals, remain poorly understood. Also, although this broad range of signals may provide complementary information channels in primary (MI) and ventral premotor (PMv) areas, areal differences in information have not been systematically examined. Here, for the first time, the amount of information in SA and multiband LFPs was compared for MI and PMv by recording from dual 96-multielectrode arrays while monkeys made naturalistic reach and grasp actions. Information was assessed as decoding accuracy for 3D arm end point and grip aperture kinematics based on SA or LFPs in MI and PMv, or combinations of signal types across areas. In contrast with previous studies with ≤16 simultaneous electrodes, here ensembles of >16 units (on average) carried more information than multiband, multichannel LFPs. Furthermore, reach and grasp information added by various LFP frequency bands was not independent from that in SA ensembles but rather typically less than and primarily contained within the latter. Notably, MI and PMv did not show a particular bias toward reach or grasp for this task or for a broad range of signal types. For BCIs, our results indicate that neuronal ensemble spiking is the preferred signal for decoding, while LFPs and combined signals from PMv and MI can add robustness to BCI control.
Truccolo, Wilson; Vargas-Irwin, Carlos E.; Donoghue, John P.
2012-01-01
Neural activity in motor cortex during reach and grasp movements shows modulations in a broad range of signals from single-neuron spiking activity (SA) to various frequency bands in broadband local field potentials (LFPs). In particular, spatiotemporal patterns in multiband LFPs are thought to reflect dendritic integration of local and interareal synaptic inputs, attentional and preparatory processes, and multiunit activity (MUA) related to movement representation in the local motor area. Nevertheless, the relationship between multiband LFPs and SA, and their relationship to movement parameters and their relative value as brain-computer interface (BCI) control signals, remain poorly understood. Also, although this broad range of signals may provide complementary information channels in primary (MI) and ventral premotor (PMv) areas, areal differences in information have not been systematically examined. Here, for the first time, the amount of information in SA and multiband LFPs was compared for MI and PMv by recording from dual 96-multielectrode arrays while monkeys made naturalistic reach and grasp actions. Information was assessed as decoding accuracy for 3D arm end point and grip aperture kinematics based on SA or LFPs in MI and PMv, or combinations of signal types across areas. In contrast with previous studies with ≤16 simultaneous electrodes, here ensembles of >16 units (on average) carried more information than multiband, multichannel LFPs. Furthermore, reach and grasp information added by various LFP frequency bands was not independent from that in SA ensembles but rather typically less than and primarily contained within the latter. Notably, MI and PMv did not show a particular bias toward reach or grasp for this task or for a broad range of signal types. For BCIs, our results indicate that neuronal ensemble spiking is the preferred signal for decoding, while LFPs and combined signals from PMv and MI can add robustness to BCI control. PMID:22157115
Vargas-Irwin, Carlos E.; Truccolo, Wilson; Donoghue, John P.
2011-01-01
A prominent feature of motor cortex field potentials during movement is a distinctive low-frequency local field potential (lf-LFP) (<4 Hz), referred to as the movement event-related potential (mEP). The lf-LFP appears to be a global signal related to regional synaptic input, but its relationship to nearby output signaled by single unit spiking activity (SUA) or to movement remains to be established. Previous studies comparing information in primary motor cortex (MI) lf-LFPs and SUA in the context of planar reaching tasks concluded that lf-LFPs have more information than spikes about movement. However, the relative performance of these signals was based on a small number of simultaneously recorded channels and units, or for data averaged across sessions, which could miss information of larger-scale spiking populations. Here, we simultaneously recorded LFPs and SUA from two 96-microelectrode arrays implanted in two major motor cortical areas, MI and ventral premotor (PMv), while monkeys freely reached for and grasped objects swinging in front of them. We compared arm end point and grip aperture kinematics′ decoding accuracy for lf-LFP and SUA ensembles. The results show that lf-LFPs provide enough information to reconstruct kinematics in both areas with little difference in decoding performance between MI and PMv. Individual lf-LFP channels often provided more accurate decoding of single kinematic variables than any one single unit. However, the decoding performance of the best single unit among the large population usually exceeded that of the best single lf-LFP channel. Furthermore, ensembles of SUA outperformed the pool of lf-LFP channels, in disagreement with the previously reported superiority of lf-LFP decoding. Decoding results suggest that information in lf-LFPs recorded from intracortical arrays may allow the reconstruction of reach and grasp for real-time neuroprosthetic applications, thus potentially supplementing the ability to decode these same features from spiking populations. PMID:21273313
2014-02-11
ISS038-E-045009 (11 Feb. 2014) --- The Small Satellite Orbital Deployer (SSOD), in the grasp of the Kibo laboratory robotic arm, is photographed by an Expedition 38 crew member on the International Space Station as it deploys a set of NanoRacks CubeSats. The CubeSats program contains a variety of experiments such as Earth observations and advanced electronics testing. Station solar array panels, Earth's horizon and the blackness of space provide the backdrop for the scene.
SEOM's Sentinel-3/OLCI' project CAWA: advanced GRASP aerosol retrieval
NASA Astrophysics Data System (ADS)
Dubovik, Oleg; litvinov, Pavel; Huang, Xin; Aspetsberger, Michael; Fuertes, David; Brockmann, Carsten; Fischer, Jürgen; Bojkov, Bojan
2016-04-01
The CAWA "Advanced Clouds, Aerosols and WAter vapour products for Sentinel-3/OLCI" ESA-SEOM project aims on the development of advanced atmospheric retrieval algorithms for the Sentinel-3/OLCI mission, and is prepared using Envisat/MERIS and Aqua/MODIS datasets. This presentation discusses mainly CAWA aerosol product developments and results. CAWA aerosol retrieval uses recently developed GRASP algorithm (Generalized Retrieval of Aerosol and Surface Properties) algorithm described by Dubovik et al. (2014). GRASP derives extended set of atmospheric parameters using multi-pixel concept - a simultaneous fitting of a large group of pixels under additional a priori constraints limiting the time variability of surface properties and spatial variability of aerosol properties. Over land GRASP simultaneously retrieves properties of both aerosol and underlying surface even over bright surfaces. GRAPS doesn't use traditional look-up-tables and performs retrieval as search in continuous space of solution. All radiative transfer calculations are performed as part of the retrieval. The results of comprehensive sensitivity tests, as well as results obtained from real Envisat/MERIS data will be presented. The tests analyze various aspects of aerosol and surface reflectance retrieval accuracy. In addition, the possibilities of retrieval improvement by means of implementing synergetic inversion of a combination of OLCI data with observations by SLSTR are explored. Both the results of numerical tests, as well as the results of processing several years of Envisat/MERIS data illustrate demonstrate reliable retrieval of AOD (Aerosol Optical Depth) and surface BRDF. Observed retrieval issues and advancements will be discussed. For example, for some situations we illustrate possibilities of retrieving aerosol absorption - property that hardly accessible from satellite observations with no multi-angular and polarimetric capabilities.
Unmanned Systems: A Lab-Based Robotic Arm for Grasping
2015-06-01
Reduction Project (0704-0188) Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE June 2015 3. REPORT TYPE AND DATES COVERED...experiments. The focus of this project is to understand and apply the kinematics and dynamics for a 6 degree of freedom (DOF) Kinova JACO robotic arm...Implementation, (3) and Operational Demonstrations This research project centered on Phase 1, while focusing on three subareas: • JACO Manipulator Set Up And
Design of a Robotic Ankle Joint for a Microspine-Based Robot
NASA Technical Reports Server (NTRS)
Thatte, Nitish
2011-01-01
Successful robotic exploration of near-Earth asteroids necessitates a method of securely anchoring to the surface of these bodies without gravitational assistance. Microspine grip- per arrays that can grasp rock faces are a potential solution to this problem. A key component of a future microspine-based rover will be the ankle used to attach each microspine gripper to the robot. The ankle's purpose is twofold: 1) to allow the gripper to conform to the rock so a higher percentage of microspines attach to the surface, and 2) to neutralize torques that may dislodge the grippers from the wall. Parts were developed using computer aided design and manufactured using a variety of methods including selective laser sintering, CNC milling, and traditional manual machining techniques. Upon completion of the final prototype, the gripper and ankle system was tested to demonstrate robotic engagement and disengagement of the gripper and to determine load bearing ability. The immediate application of this project is to out t the Lemur IIb robot so it can climb and hang from rock walls.
Cooperative Project-Based Learning in a Web-Based Software Engineering Course
ERIC Educational Resources Information Center
Piccinini, Nicola; Scollo, Giuseppe
2006-01-01
Even in self-organized project-based learning, the instructors' role re-mains critical, especially in the initial orientation provided to the students in order to grasp the educational goals and the various roles they may undertake to achieve them. In this paper we survey a few questions proposed to that purpose in a web-based software engineering…
ERIC Educational Resources Information Center
Sergovich, Aimee; Johnson, Marjorie; Wilson, Timothy D.
2010-01-01
The anatomy of the pelvis is complex, multilayered, and its three-dimensional organization is conceptually difficult for students to grasp. The aim of this project was to create an explorable and projectable stereoscopic, three-dimensional (3D) model of the female pelvis and pelvic contents for anatomical education. The model was created using…
Virtual Worlds; Real Learning: Design Principles for Engaging Immersive Environments
NASA Technical Reports Server (NTRS)
Wu (u. Sjarpm)
2012-01-01
The EMDT master's program at Full Sail University embarked on a small project to use a virtual environment to teach graduate students. The property used for this project has evolved our several iterations and has yielded some basic design principles and pedagogy for virtual spaces. As a result, students are emerging from the program with a better grasp of future possibilities.
Nanoracks CUBESAT launcher operations
2014-08-20
ISS040-E-103340 (20 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer (upper right) releases a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at center. A blue and white part of Earth and the blackness of space provide the backdrop for the scene.
Self-gated fetal cardiac MRI with tiny golden angle iGRASP: A feasibility study.
Haris, Kostas; Hedström, Erik; Bidhult, Sebastian; Testud, Frederik; Maglaveras, Nicos; Heiberg, Einar; Hansson, Stefan R; Arheden, Håkan; Aletras, Anthony H
2017-07-01
To develop and assess a technique for self-gated fetal cardiac cine magnetic resonance imaging (MRI) using tiny golden angle radial sampling combined with iGRASP (iterative Golden-angle RAdial Sparse Parallel) for accelerated acquisition based on parallel imaging and compressed sensing. Fetal cardiac data were acquired from five volunteers in gestational week 29-37 at 1.5T using tiny golden angles for eddy currents reduction. The acquired multicoil radial projections were input to a principal component analysis-based compression stage. The cardiac self-gating (CSG) signal for cardiac gating was extracted from the acquired radial projections and the iGRASP reconstruction procedure was applied. In all acquisitions, a total of 4000 radial spokes were acquired within a breath-hold of less than 15 seconds using a balanced steady-state free precession pulse sequence. The images were qualitatively compared by two independent observers (on a scale of 1-4) to a single midventricular cine image from metric optimized gating (MOG) and real-time acquisitions. For iGRASP and MOG images, good overall image quality (2.8 ± 0.4 and 2.6 ± 1.3, respectively, for observer 1; 3.6 ± 0.5 and 3.4 ± 0.9, respectively, for observer 2) and cardiac diagnostic quality (3.8 ± 0.4 and 3.4 ± 0.9, respectively, for observer 1; 3.6 ± 0.5 and 3.6 ± 0.9, respectively, for observer 2) were obtained, with visualized myocardial thickening over the cardiac cycle and well-defined myocardial borders to ventricular lumen and liver/lung tissue. For iGRASP, MOG, and real time, left ventricular lumen diameter (14.1 ± 2.2 mm, 14.2 ± 1.9 mm, 14.7 ± 1.1 mm, respectively) and wall thickness (2.7 ± 0.3 mm, 2.6 ± 0.3 mm, 3.0 ± 0.4, respectively) showed agreement and no statistically significant difference was found (all P > 0.05). Images with iGRASP tended to have higher overall image quality scores compared with MOG and particularly real-time images, albeit not statistically significant in this feasibility study (P > 0.99 and P = 0.12, respectively). Fetal cardiac cine MRI can be performed with iGRASP using tiny golden angles and CSG. Comparison with other fetal cardiac cine MRI methods showed that the proposed method produces high-quality fetal cardiac reconstructions. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:207-217. © 2017 International Society for Magnetic Resonance in Medicine.
Decoding complete reach and grasp actions from local primary motor cortex populations.
Vargas-Irwin, Carlos E; Shakhnarovich, Gregory; Yadollahpour, Payman; Mislow, John M K; Black, Michael J; Donoghue, John P
2010-07-21
How the activity of populations of cortical neurons generates coordinated multijoint actions of the arm, wrist, and hand is poorly understood. This study combined multielectrode recording techniques with full arm motion capture to relate neural activity in primary motor cortex (M1) of macaques (Macaca mulatta) to arm, wrist, and hand postures during movement. We find that the firing rate of individual M1 neurons is typically modulated by the kinematics of multiple joints and that small, local ensembles of M1 neurons contain sufficient information to reconstruct 25 measured joint angles (representing an estimated 10 functionally independent degrees of freedom). Beyond showing that the spiking patterns of local M1 ensembles represent a rich set of naturalistic movements involving the entire upper limb, the results also suggest that achieving high-dimensional reach and grasp actions with neuroprosthetic devices may be possible using small intracortical arrays like those already being tested in human pilot clinical trials.
Research Opportunities for Undergraduate Students at Storm Peak Laboratory
NASA Astrophysics Data System (ADS)
Vargas, W.; Hallar, G.
2009-12-01
GRASP (Geoscience Research at Storm Peak) is a program providing field research experiences for a diverse group of undergraduate students. GRASP is funded by the National Science Foundation. Its mission is to recruit students from underrepresented groups within the geoscience community allowing students to work and live at the Storm Peak Laboratory (SPL). Data previously collected at the facility forms the basis for continuing research projects that addresses climate change, atmospheric pollution, and cloud formation. Prior to arriving at SPL, students travel to the National Center for Atmospheric Research (NCAR) to learn about supercomputing, mathematical modeling, and scientific visualization. GRASP participants met at the campus of Howard University for a reunion workshop and presented their results in November 2008. This poster illustrates the given task and methods used to analyze an increased concentration of organic carbon detected between April 4 and 5, 2008 at SPL located at the summit of Mt. Warner in Steamboat Springs, Colorado at an elevation of 3,202 meters.
An analysis of the input-output properties of neuroprosthetic hand grasps.
Memberg, W D; Crago, P E
2000-01-01
We measured the input-output properties of the hand grasps of 14 individuals with tetraplegia at the C5/C6 level who had received an implanted upper limb neuroprosthesis. The data provide a quantitative description of grasp-opening and grasp-force control with neuroprosthetic hand grasp systems. Static properties were estimated by slowly ramping the command (input) from 0 to 100%. A hand-held sensor monitored the outputs: grasp force and grasp opening. Trials were performed at different wrist positions, with two different-sized objects being held, and with both grasp modes (lateral and palmar grasps). Larger forces were produced when grasping larger objects, and greater opening was achieved with the wrist in flexion. Although active grasp force increased with wrist extension, it was not significant statistically. Lateral grasp produced larger forces than the palmar grasp. The command range can be divided into a portion that controls grasp opening and a portion that controls grasp force. The portion controlling force increased with spacer size, but did not depend significantly on grasp mode or wrist position. The force-command relationships were more linear than the position-command relationships. Grasp opening decreased significantly over a one-year period, while no significant change in grasp force was observed. These quantitative descriptions of neuroprosthetic hand grasps under varying conditions provide useful information about output capabilities that can be used to gauge the effectiveness of different control schemes and to design future control systems.
With a cloudy horizon scene as a backdrop, the Spartan 207 free-flyer is held in the grasp of the
NASA Technical Reports Server (NTRS)
1996-01-01
STS-77 ESC VIEW --- With a cloudy horizon scene as a backdrop, the Spartan 207 free-flyer is held in the grasp of the Space Shuttle Endeavour's Remote Manipulator System (RMS) following its re-capture on May 21, 1996. The view was captured with an onboard Electronic Still Camera (ESC). The six-member crew has spent a portion of the early stages of the mission in various activities involving the Spartan 207 and the related Inflatable Antenna Experiment (IAE). The Spartan project is managed by NASA's Goddard Space Flight Center (GSFC) for NASA's Office of Space Science, Washington, D.C. GMT: 09:39:35.
Nanoracks CUBESAT launcher operations
2014-08-20
ISS040-E-103327 (20 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer (upper right) is about to release a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at center. A blue and white part of Earth and the blackness of space provide the backdrop for the scene.
Nanoracks CUBESAT launcher operations
2014-08-19
ISS040-E-103545 (19 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer (mostly out of frame, upper right) releases a pair of NanoRacks CubeSat miniature satellites (center). The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at top right. A blue and white part of Earth and the blackness of space provide the backdrop for the scene.
Effect of pencil grasp on the speed and legibility of handwriting in children.
Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl; Chau, Tom
2012-01-01
Pencil grasps other than the dynamic tripod may be functional for handwriting. This study examined the impact of grasp on handwriting speed and legibility. We videotaped 120 typically developing fourth-grade students while they performed a writing task. We categorized the grasps they used and evaluated their writing for speed and legibility using a handwriting assessment. Using linear regression analysis, we examined the relationship between grasp and handwriting. We documented six categories of pencil grasp: four mature grasp patterns, one immature grasp pattern, and one alternating grasp pattern. Multiple linear regression results revealed no significant effect for mature grasp on either legibility or speed. Pencil grasp patterns did not influence handwriting speed or legibility in this sample of typically developing children. This finding adds to the mounting body of evidence that alternative grasps may be acceptable for fast and legible handwriting. Copyright © 2012 by the American Occupational Therapy Association, Inc.
Geed, Shashwati; van Kan, Peter L. E.
2017-01-01
How are appropriate combinations of forelimb muscles selected during reach-to-grasp movements in the presence of neuromotor redundancy and important task-related constraints? The authors tested whether grasp type or target location preferentially influence the selection and synergistic coupling between forelimb muscles during reach-to-grasp movements. Factor analysis applied to 14–20 forelimb electromyograms recorded from monkeys performing reach-to-grasp tasks revealed 4–6 muscle components that showed transport/preshape- or grasp-related features. Weighting coefficients of transport/preshape-related components demonstrated strongest similarities for reaches that shared the same grasp type rather than the same target location. Scaling coefficients of transport/preshape- and grasp-related components showed invariant temporal coupling. Thus, grasp type influenced strongly both transport/preshape- and grasp-related muscle components, giving rise to grasp-based functional coupling between forelimb muscles. PMID:27589010
GRASP/Ada 95: Reverse Engineering Tools for Ada
NASA Technical Reports Server (NTRS)
Cross, James H., II
1996-01-01
The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) has successfully created and prototyped an algorithmic level graphical representation for Ada software, the Control Structure Diagram (CSD), and a new visualization for a fine-grained complexity metric called the Complexity Profile Graph (CPG). By synchronizing the CSD and the CPG, the CSD view of control structure, nesting, and source code is directly linked to the corresponding visualization of statement level complexity in the CPG. GRASP has been integrated with GNAT, the GNU Ada 95 Translator to provide a comprehensive graphical user interface and development environment for Ada 95. The user may view, edit, print, and compile source code as a CSD with no discernible addition to storage or computational overhead. The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis has been on the automatic generation of the CSD from Ada 95 source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional prettyprinted Ada source code. The current update has focused on the design and implementation of a new Motif compliant user interface, and a new CSD generator consisting of a tagger and renderer. The Complexity Profile Graph (CPG) is based on a set of functions that describes the context, content, and the scaling for complexity on a statement by statement basis. When combined graphicafly, the result is a composite profile of complexity for the program unit. Ongoing research includes the development and refinement of the associated functions, and the development of the CPG generator prototype. The current Version 5.0 prototype provides the capability for the user to generate CSDs and CPGs from Ada 95 source code in a reverse engineering as well as forward engineering mode with a level of flexibility suitable for practical application. This report provides an overview of the GRASP/Ada project with an emphasis on the current update.
The development of a program analysis environment for Ada: Reverse engineering tools for Ada
NASA Technical Reports Server (NTRS)
Cross, James H., II
1991-01-01
The Graphical Representations of Algorithms, Structures, and Processes for Ada (GRASP/Ada) has successfully created and prototyped a new algorithm level graphical representation for Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and thus improve reliability and reduce costs. The emphasis was on the automatic generation of the CSD from Ada source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional prettyprinted Ada source code. In Phase 1 of the GRASP/Ada project, the CSD graphical constructs were created and applied manually to several small Ada programs. A prototype (Version 1) was designed and implemented using FLEX and BISON running under the Virtual Memory System (VMS) on a VAX 11-780. In Phase 2, the prototype was improved and ported to the Sun 4 platform under UNIX. A user interface was designed and partially implemented. The prototype was applied successfully to numerous Ada programs ranging in size from several hundred to several thousand lines of source code. In Phase 3 of the project, the prototype was prepared for limited distribution (GRASP/Ada Version 3.0) to facilitate evaluation. The user interface was extensively reworked. The current prototype provides the capability for the user to generate CSD from Ada source code in a reverse engineering mode with a level of flexibility suitable for practical application.
An experiment in vision based autonomous grasping within a reduced gravity environment
NASA Technical Reports Server (NTRS)
Grimm, K. A.; Erickson, J. D.; Anderson, G.; Chien, C. H.; Hewgill, L.; Littlefield, M.; Norsworthy, R.
1992-01-01
The National Aeronautics and Space Administration's Reduced Gravity Program (RGP) offers opportunities for experimentation in gravities of less than one-g. The Extravehicular Activity Helper/Retriever (EVAHR) robot project of the Automation and Robotics Division at the Lyndon B. Johnson Space Center in Houston, Texas, is undertaking a task that will culminate in a series of tests in simulated zero-g using this facility. A subset of the final robot hardware consisting of a three-dimensional laser mapper, a Robotics Research 807 arm, a Jameson JH-5 hand, and the appropriate interconnect hardware/software will be used. This equipment will be flown on the RGP's KC-135 aircraft. This aircraft will fly a series of parabolas creating the effect of zero-g. During the periods of zero-g, a number of objects will be released in front of the fixed base robot hardware in both static and dynamic configurations. The system will then inspect the object, determine the objects pose, plan a grasp strategy, and execute the grasp. This must all be accomplished in the approximately 27 seconds of zero-g.
Functional classification of grasp strategies used by hemiplegic patients
Roby-Brami, Agnès; Robertson, Johanna; Roche, Nicolas
2017-01-01
This study aimed to identify and qualify grasp-types used by patients with stroke and determine the clinical parameters that could explain the use of each grasp. Thirty-eight patients with chronic stroke-related hemiparesis and a range of motor and functional capacities (17 females and 21 males, aged 25–78), and 10 healthy subjects were included. Four objects were used (tissue packet, teaspoon, bottle and tennis ball). Participants were instructed to “grasp the object as if you are going to use it”. Three trials were video-recorded for each object. A total of 456 grasps were analysed and rated using a custom-designed Functional Grasp Scale. Eight grasp-types were identified from the analysis: healthy subjects used Multi-pulpar, Pluri-digital, Lateral-pinch and Palmar grasps (Standard Grasps). Patients used the same grasps with in addition Digito-palmar, Raking, Ulnar and Interdigital grasps (Alternative Grasps). Only patients with a moderate or relatively good functional ability used Standard grasps. The correlation and regression analyses showed this was conditioned by sufficient finger and elbow extensor strength (Pluri-digital grasp); thumb extensor and wrist flexor strength (Lateral pinch) or in forearm supinator strength (Palmar grasp). By contrast, the patients who had severe impairment used Alternative grasps that did not involve the thumb. These strategies likely compensate specific impairments. Regression and correlation analyses suggested that weakness had a greater influence over grasp strategy than spasticity. This would imply that treatment should focus on improving hand strength and control although reducing spasticity may be useful in some cases. PMID:29125855
Data-driven grasp synthesis using shape matching and task-based pruning.
Li, Ying; Fu, Jiaxin L; Pollard, Nancy S
2007-01-01
Human grasps, especially whole-hand grasps, are difficult to animate because of the high number of degrees of freedom of the hand and the need for the hand to conform naturally to the object surface. Captured human motion data provides us with a rich source of examples of natural grasps. However, for each new object, we are faced with the problem of selecting the best grasp from the database and adapting it to that object. This paper presents a data-driven approach to grasp synthesis. We begin with a database of captured human grasps. To identify candidate grasps for a new object, we introduce a novel shape matching algorithm that matches hand shape to object shape by identifying collections of features having similar relative placements and surface normals. This step returns many grasp candidates, which are clustered and pruned by choosing the grasp best suited for the intended task. For pruning undesirable grasps, we develop an anatomically-based grasp quality measure specific to the human hand. Examples of grasp synthesis are shown for a variety of objects not present in the original database. This algorithm should be useful both as an animator tool for posing the hand and for automatic grasp synthesis in virtual environments.
Technology Is Power: Suggestions for Beginning Teachers
ERIC Educational Resources Information Center
Shanklin, Nancy
2010-01-01
Shanklin knows it can be hard for new teachers to incorporate all they know about technology with the realities of a classroom. She suggests setting incremental, monthly technology goals; investing in equipment; assessing students' grasp of the technology at their disposal and their use of it in classroom projects; searching purposefully for…
Exploring Young Students' Functional Thinking
ERIC Educational Resources Information Center
Warren, Elizabeth; Miller, Jodie; Cooper, Thomas J.
2013-01-01
The "Early Years Generalizing Project" ("EYGP") involves Australian years 1 to 4 (age 5 to 9) students and investigates how they grasp and express generalizations. This paper focuses on data collected from 6 Year 1 students in an exploratory study within a clinical interview setting that required students to identify function…
Purkinje cells signal hand shape and grasp force during reach-to-grasp in the monkey.
Mason, Carolyn R; Hendrix, Claudia M; Ebner, Timothy J
2006-01-01
The cerebellar cortex and nuclei play important roles in the learning, planning, and execution of reach-to-grasp and prehensile movements. However, few studies have investigated the signals carried by cerebellar neurons during reach-to-grasp, particularly signals relating to target object properties, hand shape, and grasp force. In this study, the simple spike discharge of 77 Purkinje cells was recorded as two rhesus monkeys reached and grasped 16 objects. The objects varied systematically in volume, shape, and orientation and each was grasped at five different force levels. Linear multiple regression analyses showed the simple spike discharge was significantly modulated in relation to objects and force levels. Object related modulation occurred preferentially during reach or early in the grasp and was linearly related to grasp aperture. The simple spike discharge was positively correlated with grasp force during both the reach and the grasp. There was no significant interaction between object and grasp force modulation, supporting previous kinematic findings that grasp kinematics and force are signaled independently. Singular value decomposition (SVD) was used to quantify the temporal patterns in the simple spike discharge. Most cells had a predominant discharge pattern that remained relatively constant across object grasp dimensions and force levels. A single predominant simple spike discharge pattern that spans reach and grasp and accounts for most of the variation (>60%) is consistent with the concept that the cerebellum is involved with synergies underlying prehension. Therefore Purkinje cells are involved with the signaling of prehension, providing independent signals for hand shaping and grasp force.
Roy, Rinku; Sikdar, Debdeep; Mahadevappa, Manjunatha; Kumar, C S
2018-05-19
A stable grasp is attained through appropriate hand preshaping and precise fingertip forces. Here, we have proposed a method to decode grasp patterns from motor imagery and subsequent fingertip force estimation model with a slippage avoidance strategy. We have developed a feature-based classification of electroencephalography (EEG) associated with imagination of the grasping postures. Chaotic behaviour of EEG for different grasping patterns has been utilised to capture the dynamics of associated motor activities. We have computed correlation dimension (CD) as the feature and classified with "one against one" multiclass support vector machine (SVM) to discriminate between different grasping patterns. The result of the analysis showed varying classification accuracies at different subband levels. Broad categories of grasping patterns, namely, power grasp and precision grasp, were classified at a 96.0% accuracy rate in the alpha subband. Furthermore, power grasp subtypes were classified with an accuracy of 97.2% in the upper beta subband, whereas precision grasp subtypes showed relatively lower 75.0% accuracy in the alpha subband. Following assessment of fingertip force distributions while grasping, a nonlinear autoregressive (NAR) model with proper prediction of fingertip forces was proposed for each grasp pattern. A slippage detection strategy has been incorporated with automatic recalibration of the regripping force. Intention of each grasp pattern associated with corresponding fingertip force model was virtualised in this work. This integrated system can be utilised as the control strategy for prosthetic hand in the future. The model to virtualise motor imagery based fingertip force prediction with inherent slippage correction for different grasp types ᅟ.
Effect of visual and tactile feedback on kinematic synergies in the grasping hand.
Patel, Vrajeshri; Burns, Martin; Vinjamuri, Ramana
2016-08-01
The human hand uses a combination of feedforward and feedback mechanisms to accomplish high degree of freedom in grasp control efficiently. In this study, we used a synergy-based control model to determine the effect of sensory feedback on kinematic synergies in the grasping hand. Ten subjects performed two types of grasps: one that included feedback (real) and one without feedback (memory-guided), at two different speeds (rapid and natural). Kinematic synergies were extracted from rapid real and rapid memory-guided grasps using principal component analysis. Synergies extracted from memory-guided grasps revealed greater preservation of natural inter-finger relationships than those found in corresponding synergies extracted from real grasps. Reconstruction of natural real and natural memory-guided grasps was used to test performance and generalizability of synergies. A temporal analysis of reconstruction patterns revealed the differing contribution of individual synergies in real grasps versus memory-guided grasps. Finally, the results showed that memory-guided synergies could not reconstruct real grasps as accurately as real synergies could reconstruct memory-guided grasps. These results demonstrate how visual and tactile feedback affects a closed-loop synergy-based motor control system.
Framework GRASP: routine library for optimize processing of aerosol remote sensing observation
NASA Astrophysics Data System (ADS)
Fuertes, David; Torres, Benjamin; Dubovik, Oleg; Litvinov, Pavel; Lapyonok, Tatyana; Ducos, Fabrice; Aspetsberger, Michael; Federspiel, Christian
The present the development of a Framework for the Generalized Retrieval of Aerosol and Surface Properties (GRASP) developed by Dubovik et al., (2011). The framework is a source code project that attempts to strengthen the value of the GRASP inversion algorithm by transforming it into a library that will be used later for a group of customized application modules. The functions of the independent modules include the managing of the configuration of the code execution, as well as preparation of the input and output. The framework provides a number of advantages in utilization of the code. First, it implements loading data to the core of the scientific code directly from memory without passing through intermediary files on disk. Second, the framework allows consecutive use of the inversion code without the re-initiation of the core routine when new input is received. These features are essential for optimizing performance of the data production in processing of large observation sets, such as satellite images by the GRASP. Furthermore, the framework is a very convenient tool for further development, because this open-source platform is easily extended for implementing new features. For example, it could accommodate loading of raw data directly onto the inversion code from a specific instrument not included in default settings of the software. Finally, it will be demonstrated that from the user point of view, the framework provides a flexible, powerful and informative configuration system.
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, Leigh R.; Bacher, Daniel; Jarosiewicz, Beata; Masse, Nicolas Y.; Simeral, John D.; Vogel, Joern; Haddadin, Sami; Liu, Jie; Cash, Sydney S.; van der Smagt, Patrick; Donoghue, John P.
2012-01-01
Paralysis following spinal cord injury (SCI), brainstem stroke, amyotrophic lateral sclerosis (ALS) and other disorders can disconnect the brain from the body, eliminating the ability to carry out volitional movements. A neural interface system (NIS)1–5 could restore mobility and independence for people with paralysis by translating neuronal activity directly into control signals for assistive devices. We have previously shown that people with longstanding tetraplegia can use an NIS to move and click a computer cursor and to control physical devices6–8. Able-bodied monkeys have used an NIS to control a robotic arm9, but it is unknown whether people with profound upper extremity paralysis or limb loss could use cortical neuronal ensemble signals to direct useful arm actions. Here, we demonstrate the ability of two people with long-standing tetraplegia to use NIS-based control of a robotic arm to perform three-dimensional reach and grasp movements. Participants controlled the arm over a broad space without explicit training, using signals decoded from a small, local population of motor cortex (MI) neurons recorded from a 96-channel microelectrode array. One of the study participants, implanted with the sensor five years earlier, also used a robotic arm to drink coffee from a bottle. While robotic reach and grasp actions were not as fast or accurate as those of an able-bodied person, our results demonstrate the feasibility for people with tetraplegia, years after CNS injury, to recreate useful multidimensional control of complex devices directly from a small sample of neural signals. PMID:22596161
Grasping in One-Handed Catching in Relation to Performance
Cesqui, Benedetta; Russo, Marta; Lacquaniti, Francesco; d’Avella, Andrea
2016-01-01
Catching a flying ball involves bringing the hand to the aimed interception point at the right time, adjusting the hand posture to receive the incoming ball and to absorb the ball momentum, and closing the hand to ensure a stable grip. A small error in any of these actions can lead to a failure in catching the ball. Here we sought to gather new insights on what aspects of the catching movements affect the interceptive performance most. In particular, we wondered whether the errors occurred in bringing the hand to the interception point or in closing the fingers on the ball, and whether these two phases of interception differed between individuals. To this end, we characterized grasping and wrist movement kinematics of eleven participants attempting to catch a ball projected in space with different ball arrival heights and flight durations. The spatial position of the ball and of several markers placed on the participant’s arm were recorded by a motion capture system, the hand joint angles were recorded with an instrumented glove, and several movement features were extracted. All participants were able to intercept the ball trajectory (i.e. to touch the ball) in over 90% of cases, but they differed in the ability to grasp the ball (success rate varied between 2% and 85%). Similar temporal features were observed across individuals when they caught the ball. In particular, all participants adapted their wrist movements under varying temporal and arrival height constraints, they aligned the time of peak hand closing velocity to the time of hand-ball contact, and they maintained the same hand closing duration in the different experimental conditions. These movement features characterized successful trials, and hence allowed to evaluate the possible sources of errors underlying unsuccessful trials. Thus, inter-individual and inter-trial variability in the modulation of each kinematic feature were related to catching performance. We observed that different participants used different solutions to bring the hand to the interception point. In particular the value of the wrist velocity at impact distinguished good from poor catchers. However, each individual showed similar wrist kinematics in grasped and touched trials. We also found that specific grasping features predicted the catching outcome, both on a trial-by-trial basis and across individuals of different performance level. A higher speed of hand closing distinguished touched from grasped trials. A proper triggering of the enclosing phase of the grasping movement and an accurate alignment of the peak of the hand closing speed to the impact event predicted the catching performance of different participants. These results indicate that the control of the grasping movement was the main source of errors affecting catching performance in our experiments. Moreover, these results suggest that distinct temporal and spatial features in the coordination of the grasping movement are related to individual catching abilities. PMID:27392041
Increasing the Drive of Your Physics Class
ERIC Educational Resources Information Center
Eisenstein, Stanley
2008-01-01
First-year physics students often have a difficult time grasping Newton's laws of motion and recognizing the forces that these laws depend on. The "Paper Car" project is an experiential activity that is rich in application of force principles. It is also simple enough that students are able to integrate straightforward but non-trivial physics…
Value Disciplines: A Lens for Successful Decision Making in IT
ERIC Educational Resources Information Center
Eichen, Marc
2006-01-01
To succeed professionally, a technology manager in higher education must align institutional goals with the skill set of campus technologists and the resources available for information technology (IT) support. Getting a firm grasp on any of these parameters is not easy. Resources are often committed to multiyear projects or hidden by opaque…
Learning from Action Research about Science Teacher Preparation
ERIC Educational Resources Information Center
Mitchener, Carole P.; Jackson, Wendy M.
2012-01-01
In this article, we present a case study of a beginning science teacher's year-long action research project, during which she developed a meaningful grasp of learning from practice. Wendy was a participant in the middle grade science program designed for career changers from science professions who had moved to teaching middle grade science. An…
Development of an Interactive Anatomical Three-Dimensional Eye Model
ERIC Educational Resources Information Center
Allen, Lauren K.; Bhattacharyya, Siddhartha; Wilson, Timothy D.
2015-01-01
The discrete anatomy of the eye's intricate oculomotor system is conceptually difficult for novice students to grasp. This is problematic given that this group of muscles represents one of the most common sites of clinical intervention in the treatment of ocular motility disorders and other eye disorders. This project was designed to develop a…
Score Big! Pinball Project Teaches Simple Machine Basics
ERIC Educational Resources Information Center
Freeman, Matthew K.
2009-01-01
This article presents a design brief for a pinball game. The design brief helps students get a better grasp on the operation and uses of simple machines. It also gives them an opportunity to develop their problem-solving skills and use design skills to complete an interesting, fun product. (Contains 2 tables and 3 photos.)
ERIC Educational Resources Information Center
Jarque, Maria-Josep
2005-01-01
This document illustrates that mental functioning and communication in Catalan Sign Language (LSC) are conceptual through metaphorical projection of bodily experiences. The data in this document show how concepts are grasped, put on student's heads, exchanged, manipulated, and so on, constituting instantiations of the basic metaphors: ideas are…
Effects of grasp compatibility on long-term memory for objects.
Canits, Ivonne; Pecher, Diane; Zeelenberg, René
2018-01-01
Previous studies have shown action potentiation during conceptual processing of manipulable objects. In four experiments, we investigated whether these motor actions also play a role in long-term memory. Participants categorized objects that afforded either a power grasp or a precision grasp as natural or artifact by grasping cylinders with either a power grasp or a precision grasp. In all experiments, responses were faster when the affordance of the object was compatible with the type of grasp response. However, subsequent free recall and recognition memory tasks revealed no better memory for object pictures and object names for which the grasp affordance was compatible with the grasp response. The present results therefore do not support the hypothesis that motor actions play a role in long-term memory. Copyright © 2017 Elsevier B.V. All rights reserved.
Mena–GRASP65 interaction couples actin polymerization to Golgi ribbon linking
Tang, Danming; Zhang, Xiaoyan; Huang, Shijiao; Yuan, Hebao; Li, Jie; Wang, Yanzhuang
2016-01-01
In mammalian cells, the Golgi reassembly stacking protein 65 (GRASP65) has been implicated in both Golgi stacking and ribbon linking by forming trans-oligomers through the N-terminal GRASP domain. Because the GRASP domain is globular and relatively small, but the gaps between stacks are large and heterogeneous, it remains puzzling how GRASP65 physically links Golgi stacks into a ribbon. To explore the possibility that other proteins may help GRASP65 in ribbon linking, we used biochemical methods and identified the actin elongation factor Mena as a novel GRASP65-binding protein. Mena is recruited onto the Golgi membranes through interaction with GRASP65. Depleting Mena or disrupting actin polymerization resulted in Golgi fragmentation. In cells, Mena and actin were required for Golgi ribbon formation after nocodazole washout; in vitro, Mena and microfilaments enhanced GRASP65 oligomerization and Golgi membrane fusion. Thus Mena interacts with GRASP65 to promote local actin polymerization, which facilitates Golgi ribbon linking. PMID:26538023
Fast grasping of unknown objects using principal component analysis
NASA Astrophysics Data System (ADS)
Lei, Qujiang; Chen, Guangming; Wisse, Martijn
2017-09-01
Fast grasping of unknown objects has crucial impact on the efficiency of robot manipulation especially subjected to unfamiliar environments. In order to accelerate grasping speed of unknown objects, principal component analysis is utilized to direct the grasping process. In particular, a single-view partial point cloud is constructed and grasp candidates are allocated along the principal axis. Force balance optimization is employed to analyze possible graspable areas. The obtained graspable area with the minimal resultant force is the best zone for the final grasping execution. It is shown that an unknown object can be more quickly grasped provided that the component analysis principle axis is determined using single-view partial point cloud. To cope with the grasp uncertainty, robot motion is assisted to obtain a new viewpoint. Virtual exploration and experimental tests are carried out to verify this fast gasping algorithm. Both simulation and experimental tests demonstrated excellent performances based on the results of grasping a series of unknown objects. To minimize the grasping uncertainty, the merits of the robot hardware with two 3D cameras can be utilized to suffice the partial point cloud. As a result of utilizing the robot hardware, the grasping reliance is highly enhanced. Therefore, this research demonstrates practical significance for increasing grasping speed and thus increasing robot efficiency under unpredictable environments.
Isoform-specific tethering links the Golgi ribbon to maintain compartmentalization
Jarvela, Timothy; Linstedt, Adam D.
2014-01-01
Homotypic membrane tethering by the Golgi reassembly and stacking proteins (GRASPs) is required for the lateral linkage of mammalian Golgi ministacks into a ribbon-like membrane network. Although GRASP65 and GRASP55 are specifically localized to cis and medial/trans cisternae, respectively, it is unknown whether each GRASP mediates cisternae-specific tethering and whether such specificity is necessary for Golgi compartmentalization. Here each GRASP was tagged with KillerRed (KR), expressed in HeLa cells, and inhibited by 1-min exposure to light. Significantly, inactivation of either GRASP unlinked the Golgi ribbon, and the immediate effect of GRASP65-KR inactivation was a loss of cis- rather than trans-Golgi integrity, whereas inactivation of GRASP55-KR first affected the trans- and not the cis-Golgi. Thus each GRASP appears to play a direct and cisternae-specific role in linking ministacks into a continuous membrane network. To test the consequence of loss of cisternae-specific tethering, we generated Golgi membranes with a single GRASP on all cisternae. Remarkably, the membranes exhibited the full connectivity of wild-type Golgi ribbons but were decompartmentalized and defective in glycan processing. Thus the GRASP isoforms specifically link analogous cisternae to ensure Golgi compartmentalization and proper processing. PMID:24227884
Kinematics and force analysis of a robot hand based on an artificial biological control scheme
NASA Astrophysics Data System (ADS)
Kim, Man Guen
An artificial biological control scheme (ABCS) is used to study the kinematics and statics of a multifingered hand with a view to developing an efficient control scheme for grasping. The ABCS is based on observation of human grasping, intuitively taking it as the optimum model for robotic grasping. A final chapter proposes several grasping measures to be applied to the design and control of a robot hand. The ABCS leads to the definition of two modes of the grasping action: natural grasping (NG), which is the human motion to grasp the object without any special task command, and forced grasping (FG), which is the motion with a specific task. The grasping direction line (GDL) is defined to determine the position and orientation of the object in the hand. The kinematic model of a redundant robot arm and hand is developed by reconstructing the human upper extremity and using anthropometric measurement data. The inverse kinematic analyses of various types of precision and power grasping are studied by replacing the three-link with one virtual link and using the GDL. The static force analysis for grasping with fingertips is studied by applying the ABCS. A measure of grasping stability, that maintains the positions of contacts as well as the configurations of the redundant fingers, is derived. The grasping stability measure (GSM), a measure of how well the hand maintains grasping under the existence of external disturbance, is derived by the torque vector of the hand calculated from the external force applied to the object. The grasping manipulability measure (GMM), a measure of how well the hand manipulates the object for the task, is derived by the joint velocity vector of the hand calculated from the object velocity. The grasping performance measure (GPM) is defined by the sum of the directional components of the GSM and the GMM. Finally, a planar redundant hand with two fingers is examined in order to study the various postures of the hand performing pinch grasping by applying the GSM and the GMM.
NASA Technical Reports Server (NTRS)
Liu, Hua-Kuang (Inventor)
1992-01-01
A relatively small and low-cost system is provided for projecting a large and bright television image onto a screen. A miniature liquid crystal array is driven by video circuitry to produce a pattern of transparencies in the array corresponding to a television image. Light is directed against the rear surface of the array to illuminate it, while a projection lens lies in front of the array to project the image of the array onto a large screen. Grid lines in the liquid crystal array are eliminated by a spacial filter which comprises a negative of the Fourier transform of the grid.
Stephens, Trevor K; Kong, Nathan J; Dockter, Rodney L; O'Neill, John J; Sweet, Robert M; Kowalewski, Timothy M
2018-06-01
Surgical robots are increasingly common, yet routine tasks such as tissue grasping remain potentially harmful with high occurrences of tissue crush injury due to the lack of force feedback from the grasper. This work aims to investigate whether a blended shared control framework which utilizes real-time identification of the object being grasped as part of the feedback may help address the prevalence of tissue crush injury in robotic surgeries. This work tests the proposed shared control framework and tissue identification algorithm on a custom surrogate surgical robotic grasping setup. This scheme utilizes identification of the object being grasped as part of the feedback to regulate to a desired force. The blended shared control is arbitrated between human and an implicit force controller based on a computed confidence in the identification of the grasped object. The online identification is performed using least squares based on a nonlinear tissue model. Testing was performed on five silicone tissue surrogates. Twenty grasps were conducted, with half of the grasps performed under manual control and half of the grasps performed with the proposed blended shared control, to test the efficacy of the control scheme. The identification method resulted in an average of 95% accuracy across all time samples of all tissue grasps using a full leave-grasp-out cross-validation. There was an average convergence time of [Formula: see text] ms across all training grasps for all tissue surrogates. Additionally, there was a reduction in peak forces induced during grasping for all tissue surrogates when applying blended shared control online. The blended shared control using online identification more successfully regulated grasping forces to the desired target force when compared with manual control. The preliminary work on this surrogate setup for surgical grasping merits further investigation on real surgical tools and with real human tissues.
Force feedback requirements for efficient laparoscopic grasp control.
Westebring-van der Putten, Eleonora P; van den Dobbelsteen, John J; Goossens, Richard H M; Jakimowicz, Jack J; Dankelman, Jenny
2009-09-01
During laparoscopic grasping, tissue damage may occur due to use of excessive grasp forces and tissue slippage, whereas in barehanded grasping, humans control their grasp to prevent slippage and use of excessive force (safe grasp). This study investigates the differences in grasp control during barehanded and laparoscopic lifts. Ten novices performed lifts in order to compare pinch forces under four conditions: barehanded; using tweezers; a low-efficient grasper; and a high-efficient grasper. Results showed that participants increased their pinch force significantly later during a barehanded lift (at a pull-force level of 2.63 N) than when lifting laparoscopically (from pull-force levels of 0.77 to 1.08 N). In barehanded lifts all participants could accomplish a safe grasp, whereas in laparoscopic lifts excessive force (up to 7.9 N) and slippage (up to 38% of the trials) occurred frequently. For novices, it can be concluded that force feedback (additional to the hand-tool interface), as in skin-tissue contact, is a prerequisite to maintain a safe grasp. Much is known about grasp control during barehanded object manipulation, especially the control of pinch forces to changing loading, whereas little is known about force perception and grasp control during tool usage. This knowledge is a prerequisite for the ergonomic design of tools that are used to manipulate objects.
It’s Out of My Hands! Grasping Capacity May Not Influence Perceived Object Size
2017-01-01
Linkenauger, Witt, and Proffitt (2011) found that the perceived size of graspable objects was scaled by perceived grasping capacity. However, it is possible that this effect occurred because object size was estimated on the same trial as grasping capacity. This may have led to a conflation of estimates of perceived action capacity and spatial properties. In 5 experiments, we tested Linkenauger et al.’s claim that right-handed observers overestimate the grasping capacity of their right hand relative to their left hand, and that this, in turn, leads them to underestimate the size of objects to-be-grasped in their right hand relative to their left hand. We replicated the finding that right handers overestimate the size and grasping capacity of their right hand relative to their left hand. However, when estimates of object size and grasping capacity were made in separate tasks, objects grasped in the right hand were not underestimated relative to those grasped in the left hand. Further, when grasping capacity was physically restricted, observers appropriately recalibrated their perception of their maximum grasp but estimates of object size were unaffected. Our results suggest that changes in action capacity may not influence perceived object size if sources of conflation are controlled for. PMID:28191987
A Wearable Multi-Site System for NMES-Based Hand Function Restoration.
Crema, Andrea; Malesevic, Nebojsa; Furfaro, Ivan; Raschella, Flavio; Pedrocchi, Alessandra; Micera, Silvestro
2018-02-01
Reaching and grasping impairments significantly affect the quality of life for people who have experienced a stroke or spinal cord injury. The long-term well-being of patients varies greatly according to the restorable residual capabilities. Electrical stimulation could be a promising solution to restore motor functions in these conditions, but its use is not clinically widespread. Here, we introduce the HandNMES, an electrode array (EA) for neuromuscular electrical stimulation (NMES) aimed at grasp training and assistance. The device was designed to deliver electrical stimulation to extrinsic and intrinsic hand muscles. Six independent EAs, positioned on the user forearm and hand, deliver NMES pulses originating from an external stimulator equipped with demultiplexers for interfacing with a large number of electrodes. The garment was designed to be adaptable to user needs and anthropometric characteristics; size, shape, and contact materials can be customized, and stimulation characteristics such as intensity of stimulation and virtual electrode location, and size can be adjusted. We performed extensive tests with nine healthy subjects showing the efficacy of the HandNMES in terms of stimulation performance and personalization. Because encouraging results were achieved, in the coming months, the HandNMES device will be tested in pilot clinical trials.
Manipulation Capabilities with Simple Hands
2010-01-01
allowing it to interpret online kinesthetic data, addressing two objectives: • Grasp classification: Distinguish between successful and unsuccessful...determining the grasp outcome before the grasping process is complete, by using the entire time series or kinesthetic signature of the grasping process. As...the grasp proceeds and additional kinesthetic data accumulates, the confidence also increases. In some cases Manipulation Capabilities with Simple Hands
The Relationship of Pencil Grasp on College Students' Handwriting Speed and Legibility
ERIC Educational Resources Information Center
Shah, Lalit J.; Gladson, Beth L.
2015-01-01
To be successful in school, it is important for students to be able to communicate to teachers what they know and have learned through exams, papers, daily assignments, and projects. The primary way students display this knowledge during these tasks is in written form, and thus, the skill of handwriting is essential. School-based occupational…
ERIC Educational Resources Information Center
Texas Univ., Austin. Lyndon B. Johnson School of Public Affairs.
To remain a high wage, high income society, attention must be focused on America's learning system. Educated workers and citizens should have a better grasp of technology, and vocational-technical subjects taught in the schools must contain greater academic, abstract, theoretical, and conceptual content. Reforming vocational-technical programs…
Student Training in Transversal Competences at the University of Cordoba
ERIC Educational Resources Information Center
Serrano, Rosario Merida; Romero, Julia Angulo; Bello, Manuel Jurado; Perez, Jose Diz
2011-01-01
This article describes a research project developed at the University of Cordoba during the academic year 2007-8, in which 2414 students took part, all studying courses included in a pilot scheme for the implementation of European Credit Transfer System credits. The aim was to ascertain the opinions of students in relation to their grasp and…
Distance Education in Guyana. Report of a Project Identification Consultancy. Consultant Report 3.
ERIC Educational Resources Information Center
Commonwealth of Learning, Vancouver (British Columbia).
Distance education is the only prospect of bringing further educational opportunities within the grasp of most adults in Guyana. Some factors that make distance education desirable, such as the infrastructure and present economic problems, militate against its provision. Many of the best educated personnel in all sectors have emigrated; the loss…
Learning Grasp Context Distinctions that Generalize
NASA Technical Reports Server (NTRS)
Platt, Robert; Grupen, Roderic A.; Fagg, Andrew H.
2006-01-01
Control-based approaches to grasp synthesis create grasping behavior by sequencing and combining control primitives. In the absence of any other structure, these approaches must evaluate a large number of feasible control sequences as a function of object shape, object pose, and task. This work explores a new approach to grasp synthesis that limits consideration to variations on a generalized localize-reach-grasp control policy. A new learning algorithm, known as schema structured learning, is used to learn which instantiations of the generalized policy are most likely to lead to a successful grasp in different problem contexts. Two experiments are described where Dexter, a bimanual upper torso, learns to select an appropriate grasp strategy as a function of object eccentricity and orientation. In addition, it is shown that grasp skills learned in this way can generalize to new objects. Results are presented showing that after learning how to grasp a small, representative set of objects, the robot's performance quantitatively improves for similar objects that it has not experienced before.
The continuous end-state comfort effect: weighted integration of multiple biases.
Herbort, Oliver; Butz, Martin V
2012-05-01
The grasp orientation when grasping an object is frequently aligned in anticipation of the intended rotation of the object (end-state comfort effect). We analyzed grasp orientation selection in a continuous task to determine the mechanisms underlying the end-state comfort effect. Participants had to grasp a box by a circular handle-which allowed for arbitrary grasp orientations-and then had to rotate the box by various angles. Experiments 1 and 2 revealed both that the rotation's direction considerably determined grasp orientations and that end-postures varied considerably. Experiments 3 and 4 further showed that visual stimuli and initial arm postures biased grasp orientations if the intended rotation could be easily achieved. The data show that end-state comfort but also other factors determine grasp orientation selection. A simple mechanism that integrates multiple weighted biases can account for the data.
Mathew, Hanna; Kunde, Wilfried; Herbort, Oliver
2017-05-01
When someone grasps an object, the grasp depends on the intended object manipulation and usually facilitates it. If several object manipulation steps are planned, the first step has been reported to primarily determine the grasp selection. We address whether the grasp can be aligned to the second step, if the second step's requirements exceed those of the first step. Participants grasped and rotated a dial first by a small extent and then by various extents in the opposite direction, without releasing the dial. On average, when the requirements of the first and the second step were similar, participants mostly aligned the grasp to the first step. When the requirements of the second step were considerably higher, participants aligned the grasp to the second step, even though the first step still had a considerable impact. Participants employed two different strategies. One subgroup initially aligned the grasp to the first step and then ceased adjusting the grasp to either step. Another group also initially aligned the grasp to the first step and then switched to aligning it primarily to the second step. The data suggest that participants are more likely to switch to the latter strategy when they experienced more awkward arm postures. In summary, grasp selections for multi-step object manipulations can be aligned to the second object manipulation step, if the requirements of this step clearly exceed those of the first step and if participants have some experience with the task.
Ninu, Andrei; Dosen, Strahinja; Muceli, Silvia; Rattay, Frank; Dietl, Hans; Farina, Dario
2014-09-01
In closed-loop control of grasping by hand prostheses, the feedback information sent to the user is usually the actual controlled variable, i.e., the grasp force. Although this choice is intuitive and logical, the force production is only the last step in the process of grasping. Therefore, this study evaluated the performance in controlling grasp strength using a hand prosthesis operated through a complete grasping sequence while varying the feedback variables (e.g., closing velocity, grasping force), which were provided to the user visually or through vibrotactile stimulation. The experiments were conducted on 13 volunteers who controlled the Otto Bock Sensor Hand Speed prosthesis. Results showed that vibrotactile patterns were able to replace the visual feedback. Interestingly, the experiments demonstrated that direct force feedback was not essential for the control of grasping force. The subjects were indeed able to control the grip strength, predictively, by estimating the grasping force from the prosthesis velocity of closing. Therefore, grasping without explicit force feedback is not completely blind, contrary to what is usually assumed. In our study we analyzed grasping with a specific prosthetic device, but the outcomes are also applicable for other devices, with one or more degrees-of-freedom. The necessary condition is that the electromyography (EMG) signal directly and proportionally controls the velocity/grasp force of the hand, which is a common approach among EMG controlled prosthetic devices. The results provide important indications on the design of closed-loop EMG controlled prosthetic systems.
Poor shape perception is the reason reaches-to-grasp are visually guided online.
Lee, Young-Lim; Crabtree, Charles E; Norman, J Farley; Bingham, Geoffrey P
2008-08-01
Both judgment studies and studies of feedforward reaching have shown that the visual perception of object distance, size, and shape are inaccurate. However, feedback has been shown to calibrate feedfoward reaches-to-grasp to make them accurate with respect to object distance and size. We now investigate whether shape perception (in particular, the aspect ratio of object depth to width) can be calibrated in the context of reaches-to-grasp. We used cylindrical objects with elliptical cross-sections of varying eccentricity. Our participants reached to grasp the width or the depth of these objects with the index finger and thumb. The maximum grasp aperture and the terminal grasp aperture were used to evaluate perception. Both occur before the hand has contacted an object. In Experiments 1 and 2, we investigated whether perceived shape is recalibrated by distorted haptic feedback. Although somewhat equivocal, the results suggest that it is not. In Experiment 3, we tested the accuracy of feedforward grasping with respect to shape with haptic feedback to allow calibration. Grasping was inaccurate in ways comparable to findings in shape perception judgment studies. In Experiment 4, we hypothesized that online guidance is needed for accurate grasping. Participants reached to grasp either with or without vision of the hand. The result was that the former was accurate, whereas the latter was not. We conclude that shape perception is not calibrated by feedback from reaches-to-grasp and that online visual guidance is required for accurate grasping because shape perception is poor.
NASA Astrophysics Data System (ADS)
Didkovsky, L. V.; Wieman, S. R.; Chao, W.; Woods, T. N.; Jones, A. R.; Thiemann, E.; Mason, J. P.
2016-12-01
We discuss science and technology advantages of the Imaging Grating Spectrometer (I-GRASP) based on a novel transmission diffracting grating (TDG) made possible by technology for fabricating Fresnel zone plates (ZPs) developed at the Lawrence Berkeley National Laboratory (LBNL). Older version TDGs with 200 nm period available in the 1990s became a proven technology for providing 21 years of regular measurements of solar EUV irradiance. I-GRASP incorporates an advanced TDG with a grating period of 50 nm providing four times better diffraction dispersion than the 200 nm period gratings used in the SOHO/CELIAS/SEM, the SDO/EVE/ESP flight spectrophotometers, and the EVE/SAM sounding rocket channel. Such new technology for the TDG combined with a back-illuminated 2000 x 1504 CMOS image sensor with 7 micron pixels, will provide spatially-and-spectrally resolved images and spectra from individual Active Regions (ARs) and solar flares with high (0.15 nm) spectral resolution. Such measurements are not available in the spectral band from about 2 to 6 nm from existing or planned spectrographs and will be significantly important to study ARs and solar flare temperatures and dynamics, to improve existing spectral models, e.g. CHIANTI, and to better understand processes in the Earth's atmosphere processes. To test this novel technology, we have proposed to the NASA LCAS program an I-GRASP version for a sounding rocket flight to increase the TDG TRL to a level appropriate for future CubeSat projects.
de Freitas, Paulo B; Jaric, Slobodan
2009-04-01
We evaluated coordination of the hand grip force (GF; normal component of the force acting at the hand-object contact area) and load force (LF; the tangential component) in a variety of grasping techniques and two LF directions. Thirteen participants exerted a continuous sinusoidal LF pattern against externally fixed handles applying both standard (i.e., using either the tips of the digits or the palms; the precision and palm grasps, respectively) and non-standard grasping techniques (using wrists and the dorsal finger areas; the wrist and fist grasp). We hypothesized (1) that the non-standard grasping techniques would provide deteriorated indices of force coordination when compared with the standard ones, and (2) that the nervous system would be able to adjust GF to the differences in friction coefficients of various skin areas used for grasping. However, most of the indices of force coordination remained similar across the tested grasping techniques, while the GF adjustments for the differences in friction coefficients (highest in the palm and the lowest in the fist and wrist grasp) provided inconclusive results. As hypothesized, GF relative to the skin friction was lowest in the precision grasp, but highest in the palm grasp. Therefore, we conclude that (1) the elaborate coordination of GF and LF consistently seen across the standard grasping techniques could be generalized to the non-standard ones, while (2) the ability to adjust GF using the same grasping technique to the differences in friction of various objects cannot be fully generalized to the GF adjustment when different grasps (i.e., hand segments) are used to manipulate the same object. Due to the importance of the studied phenomena for understanding both the functional and neural control aspects of manipulation, future studies should extend the current research to the transient and dynamic tasks, as well as to the general role of friction in our mechanical interactions with the environment.
Hand synergies during reach-to-grasp.
Mason, C R; Gomez, J E; Ebner, T J
2001-12-01
An emerging viewpoint is that the CNS uses synergies to simplify the control of the hand. Previous work has shown that static hand postures for mimed grasps can be described by a few principal components in which the higher order components explained only a small fraction of the variance yet provided meaningful information. Extending that earlier work, this study addressed whether the entire act of grasp can be described by a small number of postural synergies and whether these synergies are similar for different grasps. Five right-handed adults performed five types of reach-to-grasps including power grasp, power grasp with a lift, precision grasp, and mimed power grasp and mimed precision grasp of 16 different objects. The object shapes were cones, cylinders, and spindles, systematically varied in size to produce a large range of finger joint angle combinations. Three-dimensional reconstructions of 21 positions on the hand and wrist throughout the reach-to-grasp were obtained using a four-camera video system. Singular value decomposition on the temporal sequence of the marker positions was used to identify the common patterns ("eigenpostures") across the 16 objects for each task and their weightings as a function of time. The first eigenposture explained an average of 97.3 +/- 0.89% (mean +/- SD) of the variance of the hand shape, and the second another 1.9 +/- 0.85%. The first eigenposture was characterized by an open hand configuration that opens and closes during reach. The second eigenposture contributed to the control of the thumb and long fingers, particularly in the opening of the hand during the reach and the closing in preparation for object grasp. The eigenpostures and their temporal evolutions were similar across subjects and grasps. The higher order eigenpostures, although explaining only small amounts of the variance, contributed to the movements of the fingers and thumb. These findings suggest that much of reach-to-grasp is effected using a base posture with refinements in finger and thumb positions added in time to yield unique hand shapes.
Probing the reaching-grasping network in humans through multivoxel pattern decoding.
Di Bono, Maria Grazia; Begliomini, Chiara; Castiello, Umberto; Zorzi, Marco
2015-11-01
The quest for a putative human homolog of the reaching-grasping network identified in monkeys has been the focus of many neuropsychological and neuroimaging studies in recent years. These studies have shown that the network underlying reaching-only and reach-to-grasp movements includes the superior parieto-occipital cortex (SPOC), the anterior part of the human intraparietal sulcus (hAIP), the ventral and the dorsal portion of the premotor cortex, and the primary motor cortex (M1). Recent evidence for a wider frontoparietal network coding for different aspects of reaching-only and reach-to-grasp actions calls for a more fine-grained assessment of the reaching-grasping network in humans by exploiting pattern decoding methods (multivoxel pattern analysis--MVPA). Here, we used MPVA on functional magnetic resonance imaging (fMRI) data to assess whether regions of the frontoparietal network discriminate between reaching-only and reach-to-grasp actions, natural and constrained grasping, different grasp types, and object sizes. Participants were required to perform either reaching-only movements or two reach-to-grasp types (precision or whole hand grasp) upon spherical objects of different sizes. Multivoxel pattern analysis highlighted that, independently from the object size, all the selected regions of both hemispheres contribute in coding for grasp type, with the exception of SPOC and the right hAIP. Consistent with recent neurophysiological findings on monkeys, there was no evidence for a clear-cut distinction between a dorsomedial and a dorsolateral pathway that would be specialized for reaching-only and reach-to-grasp actions, respectively. Nevertheless, the comparison of decoding accuracy across brain areas highlighted their different contributions to reaching-only and grasping actions. Altogether, our findings enrich the current knowledge regarding the functional role of key brain areas involved in the cortical control of reaching-only and reach-to-grasp actions in humans, by revealing novel fine-grained distinctions among action types within a wide frontoparietal network.
Pencil grasp and children's handwriting legibility during different-length writing tasks.
Dennis, J L; Swinth, Y
2001-01-01
This study examined the influence ofpencil grasp on handwriting legibility during both short and long writing tasks in 46fourth-grade students who were typically developing. Matched samples were used to controlfor variability. Regular classroom writing assignments were scoredfor word and letter legibility, and scores were compared using a mixed repeated-measures analysis of variance design. The two independent variables were pencil grasp (dynamic tripod grasp vs. atypical grasp) and task length (short vs. long). A significant difference was found between the letter legibility scores on the short task and the letter legibility scores on the long task. Students' legibility was greater on the short task than on the long task across both grasp conditions. No significant difference was found in scores between students who used dynamic tripod grasps and those who used atypical grasps, nor was there a significant interaction between grasp and task length. No significant differences were found between word legibility scores. The results indicate that although the students in this study wrote more legibly on the short task than on the long task, the type of grasp they used did not affect their legibility. Because of the limited sample size, the results of this study should be interpreted cautiously. More research in handwriting performance and pencil grasp is needed to provide clear expectations and treatment options for students.
Decoding Grasping Movements from the Parieto-Frontal Reaching Circuit in the Nonhuman Primate.
Nelissen, Koen; Fiave, Prosper Agbesi; Vanduffel, Wim
2018-04-01
Prehension movements typically include a reaching phase, guiding the hand toward the object, and a grip phase, shaping the hand around it. The dominant view posits that these components rely upon largely independent parieto-frontal circuits: a dorso-medial circuit involved in reaching and a dorso-lateral circuit involved in grasping. However, mounting evidence suggests a more complex arrangement, with dorso-medial areas contributing to both reaching and grasping. To investigate the role of the dorso-medial reaching circuit in grasping, we trained monkeys to reach-and-grasp different objects in the dark and determined if hand configurations could be decoded from functional magnetic resonance imaging (MRI) responses obtained from the reaching and grasping circuits. Indicative of their established role in grasping, object-specific grasp decoding was found in anterior intraparietal (AIP) area, inferior parietal lobule area PFG and ventral premotor region F5 of the lateral grasping circuit, and primary motor cortex. Importantly, the medial reaching circuit also conveyed robust grasp-specific information, as evidenced by significant decoding in parietal reach regions (particular V6A) and dorsal premotor region F2. These data support the proposed role of dorso-medial "reach" regions in controlling aspects of grasping and demonstrate the value of complementing univariate with more sensitive multivariate analyses of functional MRI (fMRI) data in uncovering information coding in the brain.
Writing Forces Associated With Four Pencil Grasp Patterns in Grade 4 Children
Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl
2013-01-01
OBJECTIVE. We investigated differences in handwriting kinetics, speed, and legibility among four pencil grasps after a 10-min copy task. METHOD. Seventy-four Grade 4 students completed a handwriting assessment before and after a copy task. Grip and axial forces were measured with an instrumented stylus and force-sensitive tablet. We used multiple linear regression to analyze the relationship between grasp pattern and grip and axial forces. RESULTS. We found no kinetic differences among grasps, whether considered individually or grouped by the number of fingers on the barrel. However, when grasps were grouped according to the thumb position, the adducted grasps exhibited higher mean grip and axial forces. CONCLUSION. Grip forces were generally similar across the different grasps. Kinetic differences resulting from thumb position seemed to have no bearing on speed and legibility. Interventions for handwriting difficulties should focus more on speed and letter formation than on grasp pattern. PMID:23433277
Update of GRASP/Ada reverse engineering tools for Ada
NASA Technical Reports Server (NTRS)
Cross, James H., II
1992-01-01
The GRASP/Ada project (Graphical Representations of Algorithms, Structures, and Processes for Ada) has successfully created and prototyped a new algorithmic level graphical representation of Ada software, the Control Structure Diagram (CSD). The primary impetus for creation of the CSD was to improve the comprehension efficiency of Ada software and, as a result, improve reliability and reduce costs. The emphasis was on the automatic generation of the CSD from Ada PDL or source code to support reverse engineering and maintenance. The CSD has the potential to replace traditional prettyprinted Ada source code. In Phase 1 of the GRASP/Ada project, the CSD graphical constructs were created and applied manually to several small Ada programs. A prototype (Version 1) was designed and implemented using FLEX and BISON running under VMS on a VAS 11-780. In Phase 2, the prototype was improved and ported to the Sun 4 platform under UNIX. A user interface was designed and partially implemented using the HP widget toolkit and the X Windows System. In Phase 3, the user interface was extensively reworked using the Athena widget toolkit and X Windows. The prototype was applied successfully to numerous Ada programs ranging in size from several hundred to several thousand lines of source code. Following Phase 3, the prototype was evaluated by software engineering students at Auburn University and then updated with significant enhancements to the user interface including editing capabilities. Version 3.2 of the prototype was prepared for limited distribution to facilitate further evaluation. The current prototype provides the capability for the user to generate CSD's from Ada PDL or source code in a reverse engineering as well as forward engineering mode with a level of flexibility suitable for practical application.
LSA Low-cost Solar Array project
NASA Technical Reports Server (NTRS)
1978-01-01
The activities of the Low-Cost Silicon Solar Array Project during the period October through December, 1977 are reported. The LSSA Project is assigned responsibility for advancing silicon solar array technology while encouraging industry to reduce the price of arrays to a level at which photovoltaic electric power systems will be competitive with more conventional power sources early in the next decade. Set forth are the goals and plans with which the Project intends to accomplish this and the progress that was made during the quarter.
Low-cost Solar Array (LSA) project
NASA Technical Reports Server (NTRS)
1978-01-01
The activities of the Low-Cost Solar Array Project are described for the period April through June 1978. The Project is assigned responsibility for advancing solar array technology while encouraging industry to reduce the price of arrays to a level at which photovoltaic electric power systems will be competitive with more conventional power sources early in the next decade. Set forth are the goals and plans with which the Project intends to accomplish this and the progress that was made during the quarter.
Gentilucci, Maurizio; Campione, Giovanna Cristina; Dalla Volta, Riccardo; Bernardis, Paolo
2009-12-01
Does the mirror system affect the control of speech? This issue was addressed in behavioral and Transcranial Magnetic Stimulation (TMS) experiments. In behavioral experiment 1, participants pronounced the syllable /da/ while observing (1) a hand grasping large and small objects with power and precision grasps, respectively, (2) a foot interacting with large and small objects and (3) differently sized objects presented alone. Voice formant 1 was higher when observing power as compared to precision grasp, whereas it remained unaffected by observation of the different types of foot interaction and objects alone. In TMS experiment 2, we stimulated hand motor cortex, while participants observed the two types of grasp. Motor Evoked Potentials (MEPs) of hand muscles active during the two types of grasp were greater when observing power than precision grasp. In experiments 3-5, TMS was applied to tongue motor cortex of participants silently pronouncing the syllable /da/ and simultaneously observing power and precision grasps, pantomimes of the two types of grasps, and differently sized objects presented alone. Tongue MEPs were greater when observing power than precision grasp either executed or pantomimed. Finally, in TMS experiment 6, the observation of foot interaction with large and small objects did not modulate tongue MEPs. We hypothesized that grasp observation activated motor commands to the mouth as well as to the hand that were congruent with the hand kinematics implemented in the observed type of grasp. The commands to the mouth selectively affected postures of phonation organs and consequently basic features of phonological units.
NASA Astrophysics Data System (ADS)
Wodlinger, B.; Downey, J. E.; Tyler-Kabara, E. C.; Schwartz, A. B.; Boninger, M. L.; Collinger, J. L.
2015-02-01
Objective. In a previous study we demonstrated continuous translation, orientation and one-dimensional grasping control of a prosthetic limb (seven degrees of freedom) by a human subject with tetraplegia using a brain-machine interface (BMI). The current study, in the same subject, immediately followed the previous work and expanded the scope of the control signal by also extracting hand-shape commands from the two 96-channel intracortical electrode arrays implanted in the subject’s left motor cortex. Approach. Four new control signals, dictating prosthetic hand shape, replaced the one-dimensional grasping in the previous study, allowing the subject to control the prosthetic limb with ten degrees of freedom (three-dimensional (3D) translation, 3D orientation, four-dimensional hand shaping) simultaneously. Main results. Robust neural tuning to hand shaping was found, leading to ten-dimensional (10D) performance well above chance levels in all tests. Neural unit preferred directions were broadly distributed through the 10D space, with the majority of units significantly tuned to all ten dimensions, instead of being restricted to isolated domains (e.g. translation, orientation or hand shape). The addition of hand shaping emphasized object-interaction behavior. A fundamental component of BMIs is the calibration used to associate neural activity to intended movement. We found that the presence of an object during calibration enhanced successful shaping of the prosthetic hand as it closed around the object during grasping. Significance. Our results show that individual motor cortical neurons encode many parameters of movement, that object interaction is an important factor when extracting these signals, and that high-dimensional operation of prosthetic devices can be achieved with simple decoding algorithms. ClinicalTrials.gov Identifier: NCT01364480.
Mollazadeh, Mohsen; Davidson, Adam G.; Schieber, Marc H.; Thakor, Nitish V.
2013-01-01
The performance of brain-machine interfaces (BMIs) that continuously control upper limb neuroprostheses may benefit from distinguishing periods of posture and movement so as to prevent inappropriate movement of the prosthesis. Few studies, however, have investigated how decoding behavioral states and detecting the transitions between posture and movement could be used autonomously to trigger a kinematic decoder. We recorded simultaneous neuronal ensemble and local field potential (LFP) activity from microelectrode arrays in primary motor cortex (M1) and dorsal (PMd) and ventral (PMv) premotor areas of two male rhesus monkeys performing a center-out reach-and-grasp task, while upper limb kinematics were tracked with a motion capture system with markers on the dorsal aspect of the forearm, hand, and fingers. A state decoder was trained to distinguish four behavioral states (baseline, reaction, movement, hold), while a kinematic decoder was trained to continuously decode hand end point position and 18 joint angles of the wrist and fingers. LFP amplitude most accurately predicted transition into the reaction (62%) and movement (73%) states, while spikes most accurately decoded arm, hand, and finger kinematics during movement. Using an LFP-based state decoder to trigger a spike-based kinematic decoder [r = 0.72, root mean squared error (RMSE) = 0.15] significantly improved decoding of reach-to-grasp movements from baseline to final hold, compared with either a spike-based state decoder combined with a spike-based kinematic decoder (r = 0.70, RMSE = 0.17) or a spike-based kinematic decoder alone (r = 0.67, RMSE = 0.17). Combining LFP-based state decoding with spike-based kinematic decoding may be a valuable step toward the realization of BMI control of a multifingered neuroprosthesis performing dexterous manipulation. PMID:23536714
Neural correlates of action perception at the onset of functional grasping
Daum, Moritz M.; Handl, Andrea; Gredebäck, Gustaf
2015-01-01
Event-related potentials were recorded while infants observe congruent or incongruent grasping actions at the age when organized grasping first emerges (4–6 months of age). We demonstrate that the event-related potential component P400 encodes the congruency of power grasps at the age of 6 months (Experiment 1) and in 5-month-old infants that have developed the ability to use power grasps (Experiment 2). This effect does not extend to precision grasps, which infants cannot perform (Experiment 3). Our findings suggest that infants’ encoding of the relationship between an object and a grasping hand (the action–perception link) is highly specialized to actions and manual configurations of actions that infants are able to perform. PMID:25193947
ROTEX-TRIIFEX: Proposal for a joint FRG-USA telerobotic flight experiment
NASA Technical Reports Server (NTRS)
Hirzinger, G.; Bejczy, A. K.
1989-01-01
The concepts and main elements of a RObot Technology EXperiment (ROTEX) proposed to fly with the next German spacelab mission, D2, are presented. It provides a 1 meter size, six axis robot inside a spacelab rack, equipped with a multisensory gripper (force-torque sensors, an array of range finders, and mini stereo cameras). The robot will perform assembly and servicing tasks in a generic way, and will grasp a floating object. The man machine and supervisory control concepts for teleoperation from the spacelab and from ground are discussed. The predictive estimation schemes for an extensive use of time-delay compensating 3D computer graphics are explained.
Vergara, Margarita; Sancho-Bru, J L; Gracia-Ibáñez, V; Pérez-González, A
2014-01-01
This paper presents the results of a descriptive survey on human grasps. Sixty-four videos were selected to represent tasks performed in the main areas of activities of daily living (ADL) (personal care, meal preparation, eating, housekeeping, etc.). All the participants were right-handed. Elementary grasps were identified for each hand, and the grasp type (from a 9-type classification), the hands involved, and the duration were registered for each case. The results show that the most commonly used grasps are: pinch, non-prehensile, cylindrical, lateral pinch and lumbrical. The presence of these grasps in the areas of ADL is, however, very different (e.g., pinch is widely used in food preparation and very little in driving). Some grasps were used more frequently with one hand or when both hands were used simultaneously (e.g., special pinch was hardly used by the left hand). Knowing the grasp types most frequently used in ADL is essential to be able to assess grasp rehabilitation processes or hand prostheses development. Copyright © 2014 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Fast grasping of unknown objects using cylinder searching on a single point cloud
NASA Astrophysics Data System (ADS)
Lei, Qujiang; Wisse, Martijn
2017-03-01
Grasping of unknown objects with neither appearance data nor object models given in advance is very important for robots that work in an unfamiliar environment. The goal of this paper is to quickly synthesize an executable grasp for one unknown object by using cylinder searching on a single point cloud. Specifically, a 3D camera is first used to obtain a partial point cloud of the target unknown object. An original method is then employed to do post treatment on the partial point cloud to minimize the uncertainty which may lead to grasp failure. In order to accelerate the grasp searching, surface normal of the target object is then used to constrain the synthetization of the cylinder grasp candidates. Operability analysis is then used to select out all executable grasp candidates followed by force balance optimization to choose the most reliable grasp as the final grasp execution. In order to verify the effectiveness of our algorithm, Simulations on a Universal Robot arm UR5 and an under-actuated Lacquey Fetch gripper are used to examine the performance of this algorithm, and successful results are obtained.
Mena-GRASP65 interaction couples actin polymerization to Golgi ribbon linking.
Tang, Danming; Zhang, Xiaoyan; Huang, Shijiao; Yuan, Hebao; Li, Jie; Wang, Yanzhuang
2016-01-01
In mammalian cells, the Golgi reassembly stacking protein 65 (GRASP65) has been implicated in both Golgi stacking and ribbon linking by forming trans-oligomers through the N-terminal GRASP domain. Because the GRASP domain is globular and relatively small, but the gaps between stacks are large and heterogeneous, it remains puzzling how GRASP65 physically links Golgi stacks into a ribbon. To explore the possibility that other proteins may help GRASP65 in ribbon linking, we used biochemical methods and identified the actin elongation factor Mena as a novel GRASP65-binding protein. Mena is recruited onto the Golgi membranes through interaction with GRASP65. Depleting Mena or disrupting actin polymerization resulted in Golgi fragmentation. In cells, Mena and actin were required for Golgi ribbon formation after nocodazole washout; in vitro, Mena and microfilaments enhanced GRASP65 oligomerization and Golgi membrane fusion. Thus Mena interacts with GRASP65 to promote local actin polymerization, which facilitates Golgi ribbon linking. © 2016 Tang et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).
Learning Grasp Strategies Composed of Contact Relative Motions
NASA Technical Reports Server (NTRS)
Platt, Robert, Jr.
2007-01-01
Of central importance to grasp synthesis algorithms are the assumptions made about the object to be grasped and the sensory information that is available. Many approaches avoid the issue of sensing entirely by assuming that complete information is available. In contrast, this paper proposes an approach to grasp synthesis expressed in terms of units of control that simultaneously change the contact configuration and sense information about the object and the relative manipulator-object pose. These units of control, known as contact relative motions (CRMs), allow the grasp synthesis problem to be recast as an optimal control problem where the goal is to find a strategy for executing CRMs that leads to a grasp in the shortest number of steps. An experiment is described that uses Robonaut, the NASA-JSC space humanoid, to show that CRMs are a viable means of synthesizing grasps. However, because of the limited amount of information that a single CRM can sense, the optimal control problem may be partially observable. This paper proposes expressing the problem as a k-order Markov Decision Process (MDP) and solving it using Reinforcement Learning. This approach is tested in a simulation of a two-contact manipulator that learns to grasp an object. Grasp strategies learned in simulation are tested on the physical Robonaut platform and found to lead to grasp configurations consistently.
Development of a bio-inspired UAV perching system
NASA Astrophysics Data System (ADS)
Xie, Pu
Although technologies of unmanned aerial vehicles (UAVs) including micro air vehicles (MAVs) have been greatly advanced in the recent years, it is still very difficult for a UAV to perform some very challenging tasks such as perching to any desired spot reliably and agilely like a bird. Unlike the UAVs, the biological control mechanism of birds has been optimized through millions of year evolution and hence, they can perform many extremely maneuverability tasks, such as perching or grasping accurately and robustly. Therefore, we have good reason to learn from the nature in order to significantly improve the capabilities of UAVs. The development of a UAV perching system is becoming feasible, especially after a lot of research contributions in ornithology which involve the analysis of the bird's functionalities. Meanwhile, as technology advances in many engineering fields, such as airframes, propulsion, sensors, batteries, micro-electromechanical-system (MEMS), and UAV technology is also advancing rapidly. All of these research efforts in ornithology and the fast growing development technologies in UAV applications are motivating further interests and development in the area of UAV perching and grasping research. During the last decade, the research contributions about UAV perching and grasping were mainly based on fixed-wing, flapping-wing, and rotorcraft UAVs. However, most of the current researches in UAV systems with perching and grasping capability are focusing on either active (powered) grasping and perching or passive (unpowered) perching. Although birds do have both active and passive perching capabilities depending on their needs, there is no UAV perching system with both capabilities. In this project, we focused on filling this gap. Inspired by the anatomy analysis of bird legs and feet, a novel perching system has been developed to implement the bionics action for both active grasping and passive perching. In addition, for developing a robust and autonomous perching system, the following objectives were included for this project. The statics model was derived through both quasi-static and analytical method. The grasping stable condition and grasping target of the mechanical gripper were studied through the static analysis. Furthermore, the contact behavior between each foot and the perched object was modeled and evaluated on SimMechanics based on the contact force model derived through virtual principle. The kinematics modeling of UAV perching system was governed with Euler angles and quaternions. Also the propulsion model of the brushless motors was introduced and calibrated. In addition, the flight dynamics model of the UAV system was developed for simulation-based analysis prior to developing a hardware prototype and flight experiment. A special inertial measurement unit (IMU) was designed which has the capability of indirectly calculating the angular acceleration from the angular velocity and the linear acceleration readings. Moreover, a commercial-of-the-shelf (COTS) autopilot-APM 2.6 was selected for the autonomous flight control of the quadrotor. The APM 2.6 is a complete open source autopilot system, which allows the user to turn any fixed, rotary wing or multi-rotor vehicle into a fully autonomous vehicle and capable of performing programmed GPS missions with pre-programed waypoints. In addition, algorithms for inverted pendulum control and autonomous perching control was introduced. The proportion-integrate-differential (PID) controller was used for the simplified UAV perching with inverted pendulum model for horizontal balance. The performance of the controller was verified through both simulation and experiment. In addition, for the purpose of achieving the autonomous perching, guidance and control algorithms were developed the UAV perching system. For guidance, the desired flight trajectory was developed based on a bio-behavioral tau theory which was established from studying the natural motion patterns of animals and human arms approaching to a fixed or moving target for grasping or capturing. The autonomous flight control was also implemented through a PID controller. Autonomous flight performance was proved through simulation in SimMechanics. Finally, the prototyping of our designs were conducted in different generations of our bio-inspired UAV perching system, which include the leg prototype, gripper prototype, and system prototype. Both the machined prototype and 3D printed prototype were tried. The performance of these prototypes was tested through experiments.
Grasping with the eyes of your hands: hapsis and vision modulate hand preference.
Stone, Kayla D; Gonzalez, Claudia L R
2014-02-01
Right-hand preference has been demonstrated for visually guided reaching and grasping. Grasping, however, requires the integration of both visual and haptic cues. To what extent does vision influence hand preference for grasping? Is there a hand preference for haptically guided grasping? Two experiments were designed to address these questions. In Experiment 1, individuals were tested in a reaching-to-grasp task with vision (sighted condition) and with hapsis (blindfolded condition). Participants were asked to put together 3D models using building blocks scattered on a tabletop. The models were simple, composed of ten blocks of three different shapes. Starting condition (Vision-First or Hapsis-First) was counterbalanced among participants. Right-hand preference was greater in visually guided grasping but only in the Vision-First group. Participants who initially built the models while blindfolded (Hapsis-First group) used their right hand significantly less for the visually guided portion of the task. To investigate whether grasping using hapsis modifies subsequent hand preference, participants received an additional haptic experience in a follow-up experiment. While blindfolded, participants manipulated the blocks in a container for 5 min prior to the task. This additional experience did not affect right-hand use on visually guided grasping but had a robust effect on haptically guided grasping. Together, the results demonstrate first that hand preference for grasping is influenced by both vision and hapsis, and second, they highlight how flexible this preference could be when modulated by hapsis.
50TH Project Air Force, 1946 - 1996.
1996-01-01
the study results challenged current doctrine on the uses of airpower by suggesting...FORCE gives us a unique opportunity to reflect on past achieve- ments and the legacy they provide for the future. The essays in this volume offer a...montage of per- sonal perspectives on that legacy. While they do not present a comprehensive history they help us grasp the significance of
IMPROVING AND EXTENDING THE JUNIOR HIGH SCHOOL ORCHESTRA REPERTORY. FINAL REPORT.
ERIC Educational Resources Information Center
MOORE, JUNE
THE BASIC AIM OF THIS 1966-67 PROJECT WAS TO ENRICH AS WELL AS EDUCATE THOSE JUNIOR HIGH SCHOOL ORCHESTRA STUDENTS WHO WILL BE THE MATURE MUSIC AUDIENCES OF THE FUTURE. A SURVEY WAS CONDUCTED OF SUITABLY ARRANGED ORCHESTRA LITERATURE WITHIN THE GRASP OF JUNIOR HIGH SCHOOL ORCHESTRA STUDENTS, AND 64 CORE SELECTIONS WERE MADE. THE MUSIC WAS…
New Ratings of Humanities Journals Do More than Rank--They Rankle
ERIC Educational Resources Information Center
Howard, Jennifer
2008-01-01
This paper reports that a large-scale, multinational attempt in Europe to rank humanities journals has set off a revolt. In a protest letter, some journal editors have called it "a dangerous and misguided exercise." The project has also started a drumbeat of alarm in this country, as U.S.-based scholars begin to grasp the implications…
Stylized Figures: Inspired by Native American Art
ERIC Educational Resources Information Center
Jensen, Susie B.
2013-01-01
Teaching elementary-level art in the Pacific Northwest makes it natural for the author to develop a lesson based on Native American art of the area. The designs of the Northwest Indians can sometimes be a bit too sophisticated for the students to grasp, however, and it can be frustrating when developing such a project. Over a Labor Day weekend,…
McMahon, Naoimh E.; Watkins, Caroline L.; Eng, Janice J.
2014-01-01
Background Only a small percentage of research is ever successfully translated into practice. The Graded Repetitive Arm Supplementary Program (GRASP) is a stroke rehabilitation intervention that anecdotally has had rapid translation from research to clinical practice. This study was conducted to explore the characteristics of this practice implementation. Objectives The aims of this study were: (1) to explore the extent of practice implementation of GRASP in the United Kingdom; (2) using an implementation framework, to explore UK therapists' opinions of implementing GRASP; and (3) if GRASP is found to be used in the United Kingdom, to investigate differences in opinions between therapists who are using GRASP in practice and those who are not. Design A cross-sectional study design was used. Methods Data were collected via an online questionnaire. Participants in this study were members of the College of Occupational Therapy Specialist Section Neurological Practice and the Association of Chartered Physiotherapists Interested in Neurology. Results Of the 274 therapists who responded to the survey, 61 (22.3%) had experience of using GRASP, 114 (41.6%) knew of GRASP but had never used it, and 99 (36.1%) had never heard of GRASP. Therapists displayed positive opinions toward the implementation of a manual with graded progressions of structured upper limb exercises for people after stroke. Opinions were different between therapists who had used GRASP and those who had not. Limitations The findings of this study may be limited by response bias. Conclusions GRASP is a relatively new stroke rehabilitation intervention that has made impressive translation into the knowledge and practice of UK therapists. Therapists' opinions would suggest that GRASP is both an acceptable and feasible intervention and has the potential to be implemented by a greater number of therapists in a range of settings. PMID:24505098
The destination defines the journey: an examination of the kinematics of hand-to-mouth movements
Gonzalez, Claudia L. R.
2016-01-01
Long-train electrical stimulation of the motor and premotor cortices of nonhuman primates can produce either hand-to-mouth or grasp-to-inspect movements, depending on the precise location of stimulation. Furthermore, single-neuron recording studies identify discrete neuronal populations in the inferior parietal and ventral premotor cortices that respond uniquely to either grasp-to-eat or grasp-to-place movements, despite their identical mechanistic requirements. These studies demonstrate that the macaque motor cortex is organized around producing functional, goal-oriented movements, rather than simply fulfilling muscular prerequisites of action. In humans, right-handed hand-to-mouth movements have a unique kinematic signature; smaller maximum grip apertures are produced when grasping to eat than when grasping to place identical targets. This is evidence that the motor cortex in humans is also organized around producing functional movements. However, in both macaques and humans, grasp-to-eat/hand-to-mouth movements have always been elicited using edible targets and have (necessarily) been paired with mouth movement. It is therefore unknown whether the kinematic distinction is a natural result of grasping food and/or is simply attributable to concurrent opening of the mouth while grasping. In experiment 1, we used goal-differentiated grasping tasks, directed toward edible and inedible targets, to show that the unique kinematic signature is present even with inedible targets. In experiment 2, we used the same goal-differentiated grasping tasks, either coupled with or divorced from an open-mouth movement, to show that the signature is not attributable merely to a planned opening of the mouth during the grasp. These results are discussed in relation to the role of hand-to-mouth movements in human development, independently of grasp-to-eat behavior. PMID:27512020
Tactility as a function of grasp force: Effects of glove, orientation, pressure, load, and handle
NASA Technical Reports Server (NTRS)
Bishu, Ram R.; Bronkema, Lisa A.; Garcia, Dishayne; Klute, Glenn; Rajulu, Sudhakar
1994-01-01
One of the reasons for reduction in performance when gloves are donned is the lack of tactile sensitivity. It was argued that grasping force for a weight to be grasped will be a function of the weight to be lifted and the hand conditions. It was further reasoned that the differences in grasping force for various hand conditions will be a correlate of the tactile sensitivity of the corresponding hand conditions. The objective of this experiment, therefore, was to determine the effects of glove type, pressure, and weight of load on the initial grasping force and stable grasping force. It was hypothesized that when a person grasps an object, he/she grasps very firmly initially and then releases the grasp slightly after realizing what force is needed to maintain a steady grasp. This would seem to be particularly true when a person is wearing a glove and has lost some tactile sensitivity and force feedback during the grasp. Therefore, the ratio of initial force and stable force and the stable force itself would represent the amount of tactile adjustment that is made when picking up an object, and this adjustment should vary with the use of gloves. A dynamometer was fabricated to measure the grasping force; the tests were performed inside a glove box. Four female and four male subjects participated in the study, which measured the effects of four variables: load effect, gender effect, glove type, and pressure variance. The only significant effects on the peak and stable force were caused by gender and the weight of the load lifted. Neither gloves nor pressure altered these forces when compared to a bare-handed condition, as was suspected before the test. It is possible that gloves facilitate in holding due to coefficient of friction while they deter in peak grasp strength.
Coordination of pincer grasp and transport after mechanical perturbation of the index finger
Schettino, Luis F.; Adamovich, Sergei V.
2017-01-01
Our understanding of reach-to-grasp movements has evolved from the original formulation of the movement as two semi-independent visuomotor channels to one of interdependence. Despite a number of important contributions involving perturbations of the reach or the grasp, some of the features of the movement, such as the presence or absence of coordination between the digits during the pincer grasp and the extent of spatio-temporal interdependence between the transport and the grasp, are still unclear. In this study, we physically perturbed the index finger into extension during grasping closure on a minority of trials to test whether modifying the movement of one digit would affect the movement of the opposite digit, suggestive of an overarching coordinative process. Furthermore, we tested whether disruption of the grasp results in the modification of kinematic parameters of the transport. Our results showed that a continuous perturbation to the index finger affected wrist velocity but not lateral displacement. Moreover, we found that the typical flexion of the thumb observed in nonperturbed trials was delayed until the index finger counteracted the extension force. These results suggest that physically perturbing the grasp modifies the kinematics of the transport component, indicating a two-way interdependence of the reach and the grasp. Furthermore, a perturbation to one digit affects the kinematics of the other, supporting a model of grasping in which the digits are coordinated by a higher-level process rather than being independently controlled. NEW & NOTEWORTHY A current debate concerning the neural control of prehension centers on the question of whether the digits in a pincer grasp are controlled individually or together. Employing a novel approach that perturbs mechanically the grasp component during a natural reach-to-grasp movement, this work is the first to test a key hypothesis: whether perturbing one of the digits during the movement affects the other. Our results support the idea that the digits are not independently controlled. PMID:28331008
Grasp with hand and mouth: a kinematic study on healthy subjects.
Gentilucci, M; Benuzzi, F; Gangitano, M; Grimaldi, S
2001-10-01
Neurons involved in grasp preparation with hand and mouth were previously recorded in the premotor cortex of monkey. The aim of the present kinematic study was to determine whether a unique planning underlies the act of grasping with hand and mouth in humans as well. In a set of four experiments, healthy subjects reached and grasped with the hand an object of different size while opening the mouth (experiments 1 and 3), or extending the other forearm (experiment 4), or the fingers of the other hand (experiment 5). In a subsequent set of three experiments, subjects grasped an object of different size with the mouth, while opening the fingers of the right hand (experiments 6-8). The initial kinematics of mouth and finger opening, but not of forearm extension, was affected by the size of the grasped object congruently with the size effect on initial grasp kinematics. This effect was due neither to visual presentation of the object, without the successive grasp motor act (experiment 2) nor to synchronism between finger and mouth opening (experiments 3, 7, and 8). In experiment 9 subjects grasped with the right hand an object of different size while pronouncing a syllable printed on the target. Mouth opening and sound production were affected by the grasped object size. The results of the present study are discussed according to the notion that in an action each motor act is prepared before the beginning of the motor sequence. Double grasp preparation can be used for successive motor acts on the same object as, for example, grasping food with the hand and ingesting it after bringing it to the mouth. We speculate that the circuits involved in double grasp preparation might have been the neural substrate where hand motor patterns used as primitive communication signs were transferred to mouth articulation system. This is in accordance with the hypothesis that Broca's area derives phylogenetically from the monkey premotor area where hand movements are controlled.
Grasp frequency and usage in daily household and machine shop tasks.
Bullock, Ian M; Zheng, Joshua Z; De La Rosa, Sara; Guertler, Charlotte; Dollar, Aaron M
2013-01-01
In this paper, we present results from a study of prehensile human hand use during the daily work activities of four subjects: two housekeepers and two machinists. Subjects wore a head-mounted camera that recorded their hand usage during their daily work activities in their typical place of work. For each subject, 7.45 hours of video was analyzed, recording the type of grasp being used and its duration. From this data, we extracted overall grasp frequency, duration distributions for each grasp, and common transitions between grasps. The results show that for 80 percent of the study duration the housekeepers used just five grasps and the machinists used 10. The grasping patterns for the different subjects were compared, and the overall top 10 grasps are discussed in detail. The results of this study not only lend insight into how people use their hands during daily tasks, but can also inform the design of effective robotic and prosthetic hands.
Writing forces associated with four pencil grasp patterns in grade 4 children.
Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl; Chau, Tom
2013-01-01
OBJECTIVE. We investigated differences in handwriting kinetics, speed, and legibility among four pencil grasps after a 10-min copy task. METHOD. Seventy-four Grade 4 students completed a handwriting assessment before and after a copy task. Grip and axial forces were measured with an instrumented stylus and force-sensitive tablet. We used multiple linear regression to analyze the relationship between grasp pattern and grip and axial forces. RESULTS. We found no kinetic differences among grasps, whether considered individually or grouped by the number of fingers on the barrel. However, when grasps were grouped according to the thumb position, the adducted grasps exhibited higher mean grip and axial forces. CONCLUSION. Grip forces were generally similar across the different grasps. Kinetic differences resulting from thumb position seemed to have no bearing on speed and legibility. Interventions for handwriting difficulties should focus more on speed and letter formation than on grasp pattern. Copyright © 2013 by the American Occupational Therapy Association, Inc.
Connell, Louise A; McMahon, Naoimh E; Harris, Jocelyn E; Watkins, Caroline L; Eng, Janice J
2014-08-12
The Graded Repetitive Arm Supplementary Program (GRASP) is a hand and arm exercise programme designed to increase the intensity of exercise achieved in inpatient stroke rehabilitation. GRASP was shown to be effective in a randomised controlled trial in 2009 and has since experienced unusually rapid uptake into clinical practice. The aim of this study was to conduct a formative evaluation of the implementation of GRASP to inform the development and implementation of a similar intervention in the United Kingdom. Semi-structured interviews were conducted with therapists who were involved in implementing GRASP at their work site, or who had experience of using GRASP. Normalisation Process Theory (NPT), a sociological theory used to explore the processes of embedding innovations in practice, was used to develop an interview guide. Intervention components outlined within the GRASP Guideline Manual were used to develop prompts to explore how therapists use GRASP in practice. Interview transcripts were analysed using a coding frame based on implementation theory. Twenty interviews were conducted across eight sites in British Columbia Canada. Therapists identified informal networks and the free online availability of GRASP as key factors in finding out about the intervention. All therapists reported positive opinions about the value of GRASP. At all sites, therapists identified individuals who advocated for the use of GRASP, and in six of the eight sites this was the practice leader or senior therapist. Rehabilitation assistants were identified as instrumental in delivering GRASP in almost all sites as they were responsible for organising the GRASP equipment and assisting patients using GRASP. Almost all intervention components were found to be adapted to some degree when used in clinical practice; coverage was wider, the content adapted, and the dose, when monitored, was less. Although GRASP has translated into clinical practice, it is not always used in the way in which it was shown to be effective. This formative evaluation has informed the development of a novel intervention which aims to bridge this evidence-practice gap in upper limb rehabilitation after stroke.
Heinrich, Frank; Nanda, Hirsh; Goh, Haw Zan; Bachert, Collin; Lösche, Mathias; Linstedt, Adam D.
2014-01-01
The mammalian Golgi reassembly stacking protein (GRASP) proteins are Golgi-localized homotypic membrane tethers that organize Golgi stacks into a long, contiguous ribbon-like structure. It is unknown how GRASPs undergo trans pairing given that cis interactions between the proteins in the plane of the membrane are intrinsically favored. To test the hypothesis that myristoylation of the self-interacting GRASP domain restricts its orientation on the membrane to favor trans pairing, we established an in vitro assay that recapitulates GRASP-dependent membrane tethering and used neutron reflection under similar conditions to determine the orientation of the GRASP domain. In vivo, the membrane association of GRASP proteins is conferred by the simultaneous insertion of an N-terminal myristic acid and binding to a Golgi-associated binding partner. In our assay, the latter contact was replaced using a C-terminal hexa-His moiety, which bound to Ni2+-conjugated lipids incorporated into a substrate-supported bilayer lipid membrane. Nonmyristoylated protein lacked a fixed orientation on the membrane and inefficiently tethered liposomes. In contrast, myristoylated GRASP promoted tethering and exhibited a unique membrane complex. Thus, myristoylation restricts the membrane orientation of the GRASP domain favoring interactions in trans for membrane tethering. PMID:24505136
GRASP55 Senses Glucose Deprivation through O-GlcNAcylation to Promote Autophagosome-Lysosome Fusion.
Zhang, Xiaoyan; Wang, Leibin; Lak, Behnam; Li, Jie; Jokitalo, Eija; Wang, Yanzhuang
2018-04-23
The Golgi apparatus is the central hub for protein trafficking and glycosylation in the secretory pathway. However, how the Golgi responds to glucose deprivation is so far unknown. Here, we report that GRASP55, the Golgi stacking protein located in medial- and trans-Golgi cisternae, is O-GlcNAcylated by the O-GlcNAc transferase OGT under growth conditions. Glucose deprivation reduces GRASP55 O-GlcNAcylation. De-O-GlcNAcylated GRASP55 forms puncta outside of the Golgi area, which co-localize with autophagosomes and late endosomes/lysosomes. GRASP55 depletion reduces autophagic flux and results in autophagosome accumulation, while expression of an O-GlcNAcylation-deficient mutant of GRASP55 accelerates autophagic flux. Biochemically, GRASP55 interacts with LC3-II on the autophagosomes and LAMP2 on late endosomes/lysosomes and functions as a bridge between LC3-II and LAMP2 for autophagosome and lysosome fusion; this function is negatively regulated by GRASP55 O-GlcNAcylation. Therefore, GRASP55 senses glucose levels through O-GlcNAcylation and acts as a tether to facilitate autophagosome maturation. Copyright © 2018 Elsevier Inc. All rights reserved.
No tension between assembly models of super massive black hole binaries and pulsar observations.
Middleton, Hannah; Chen, Siyuan; Del Pozzo, Walter; Sesana, Alberto; Vecchio, Alberto
2018-02-08
Pulsar timing arrays are presently the only means to search for the gravitational wave stochastic background from super massive black hole binary populations, considered to be within the grasp of current or near-future observations. The stringent upper limit from the Parkes Pulsar Timing Array has been interpreted as excluding (>90% confidence) the current paradigm of binary assembly through galaxy mergers and hardening via stellar interaction, suggesting evolution is accelerated or stalled. Using Bayesian hierarchical modelling we consider implications of this upper limit for a range of astrophysical scenarios, without invoking stalling, nor more exotic physical processes. All scenarios are fully consistent with the upper limit, but (weak) bounds on population parameters can be inferred. Recent upward revisions of the black hole-galaxy bulge mass relation are disfavoured at 1.6σ against lighter models. Once sensitivity improves by an order of magnitude, a non-detection will disfavour the most optimistic scenarios at 3.9σ.
Spatiotemporal distribution of location and object effects in reach-to-grasp kinematics
Rouse, Adam G.
2015-01-01
In reaching to grasp an object, the arm transports the hand to the intended location as the hand shapes to grasp the object. Prior studies that tracked arm endpoint and grip aperture have shown that reaching and grasping, while proceeding in parallel, are interdependent to some degree. Other studies of reaching and grasping that have examined the joint angles of all five digits as the hand shapes to grasp various objects have not tracked the joint angles of the arm as well. We, therefore, examined 22 joint angles from the shoulder to the five digits as monkeys reached, grasped, and manipulated in a task that dissociated location and object. We quantified the extent to which each angle varied depending on location, on object, and on their interaction, all as a function of time. Although joint angles varied depending on both location and object beginning early in the movement, an early phase of location effects in joint angles from the shoulder to the digits was followed by a later phase in which object effects predominated at all joint angles distal to the shoulder. Interaction effects were relatively small throughout the reach-to-grasp. Whereas reach trajectory was influenced substantially by the object, grasp shape was comparatively invariant to location. Our observations suggest that neural control of reach-to-grasp may occur largely in two sequential phases: the first determining the location to which the arm transports the hand, and the second shaping the entire upper extremity to grasp and manipulate the object. PMID:26445870
Report on the Stanford/Ames direct-link space suit prehensor
NASA Technical Reports Server (NTRS)
Jameson, J. W.; Leifer, Larry
1987-01-01
Researchers at the Center for Design Research at Stanford University, in collaboration with NASA Ames at Moffet Field, California, are developing hand-powered mechanical prehensors to replace gloves for EVA spacesuits. The design and functional properties of the first version Direct Link Prehensor (DLP) is discussed. It has a total of six degrees-of-freedom and is the most elaborate of three prehensors being developed for the project. The DLP has a robust design and utilizes only linkages and revolute joints for the drive system. With its anthropomorphic configuration of two fingers and a thumb, it is easy to control and is capable of all of the basic prehension patterns such as cylindrical or lateral pinch grasps. Kinematic analysis reveals that, assuming point contacts, a grasped object can be manipulated with three degrees-of-freedom. Yet, in practice more degrees-of-freedom are possible.
Rand, Miya Kato; Lemay, Martin; Squire, Linda M; Shimansky, Yury P; Stelmach, George E
2010-03-01
The present project was aimed at investigating how two distinct and important difficulties (coordination difficulty and pronounced dependency on visual feedback) in Parkinson's disease (PD) affect each other for the coordination between hand transport toward an object and the initiation of finger closure during reach-to-grasp movement. Subjects with PD and age-matched healthy subjects made reach-to-grasp movements to a dowel under conditions in which the target object and/or the hand were either visible or not visible. The involvement of the trunk in task performance was manipulated by positioning the target object within or beyond the participant's outstretched arm to evaluate the effects of increasing the complexity of intersegmental coordination under different conditions related to the availability of visual feedback in subjects with PD. General kinematic characteristics of the reach-to-grasp movements of the subjects with PD were altered substantially by the removal of target object visibility. Compared with the controls, the subjects with PD considerably lengthened transport time, especially during the aperture closure period, and decreased peak velocity of wrist and trunk movement without target object visibility. Most of these differences were accentuated when the trunk was involved. In contrast, these kinematic parameters did not change depending on the visibility of the hand for both groups. The transport-aperture coordination was assessed in terms of the control law according to which the initiation of aperture closure during the reach occurred when the hand distance-to-target crossed a hand-target distance threshold for grasp initiation that is a function of peak aperture, hand velocity and acceleration, trunk velocity and acceleration, and trunk-target distance at the time of aperture closure initiation. When the hand or the target object was not visible, both groups increased the hand-target distance threshold for grasp initiation compared to its value under full visibility, implying an increase in the hand-target distance-related safety margin for grasping. The increase in the safety margin due to the absence of target object vision or the absence of hand vision was accentuated in the subjects with PD compared to that in the controls. The pronounced increase in the safety margin due to absence of target object vision for the subjects with PD was further accentuated when the trunk was involved compared to when it was not involved. The results imply that individuals with PD have significant limitations regarding neural computations required for efficient utilization of internal representations of target object location and hand motion as well as proprioceptive information about the hand to compensate for the lack of visual information during the performance of complex multisegment movements.
Neural coordination during reach-to-grasp
Vaidya, Mukta; Kording, Konrad; Saleh, Maryam; Takahashi, Kazutaka
2015-01-01
When reaching to grasp, we coordinate how we preshape the hand with how we move it. To ask how motor cortical neurons participate in this coordination, we examined the interactions between reach- and grasp-related neuronal ensembles while monkeys reached to grasp a variety of different objects in different locations. By describing the dynamics of these two ensembles as trajectories in a low-dimensional state space, we examined their coupling in time. We found evidence for temporal compensation across many different reach-to-grasp conditions such that if one neural trajectory led in time the other tended to catch up, reducing the asynchrony between the trajectories. Granger causality revealed bidirectional interactions between reach and grasp neural trajectories beyond that which could be attributed to the joint kinematics that were consistently stronger in the grasp-to-reach direction. Characterizing cortical coordination dynamics provides a new framework for understanding the functional interactions between neural populations. PMID:26224773
Grasp posture alters visual processing biases near the hands
Thomas, Laura E.
2015-01-01
Observers experience biases in visual processing for objects within easy reach of their hands that may assist them in evaluating items that are candidates for action. I investigated the hypothesis that hand postures affording different types of actions differentially bias vision. Across three experiments, participants performed global motion detection and global form perception tasks while their hands were positioned a) near the display in a posture affording a power grasp, b) near the display in a posture affording a precision grasp, or c) in their laps. Although the power grasp posture facilitated performance on the motion task, the precision grasp posture instead facilitated performance on the form task. These results suggest that the visual system weights processing based on an observer’s current affordances for specific actions: fast and forceful power grasps enhance temporal sensitivity, while detail-oriented precision grasps enhance spatial sensitivity. PMID:25862545
Human grasp assist device and method of use
NASA Technical Reports Server (NTRS)
Linn, Douglas Martin (Inventor); Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor)
2012-01-01
A grasp assist device includes a glove portion having phalange rings, contact sensors for measuring a grasping force applied by an operator wearing the glove portion, and a tendon drive system (TDS). The device has flexible tendons connected to the phalange rings for moving the rings in response to feedback signals from the sensors. The TDS is connected to each of the tendons, and applies an augmenting tensile force thereto via a microcontroller adapted for determining the augmenting tensile force as a function of the grasping force. A method of augmenting a grasping force of an operator includes measuring the grasping force using the sensors, encoding the grasping force as the feedback signals, and calculating the augmenting tensile force as a function of the feedback signals using the microcontroller. The method includes energizing at least one actuator of a tendon drive system (TDS) to thereby apply the augmenting tensile force.
GRASP1 regulates synaptic plasticity and learning through endosomal recycling of AMPA receptors
Chiu, Shu-Ling; Diering, Graham Hugh; Ye, Bing; Takamiya, Kogo; Chen, Chih-Ming; Jiang, Yuwu; Niranjan, Tejasvi; Schwartz, Charles E.; Wang, Tao; Huganir, Richard L.
2017-01-01
Summary Learning depends on experience-dependent modification of synaptic efficacy and neuronal connectivity in the brain. We provide direct evidence for physiological roles of the recycling endosome protein GRASP1 in glutamatergic synapse function and animal behavior. Mice lacking GRASP1 showed abnormal excitatory synapse number, synaptic plasticity and hippocampal-dependent learning and memory due to a failure in learning-induced synaptic AMPAR incorporation. We identified two GRASP1 point mutations from intellectual disability (ID) patients that showed convergent disruptive effects on AMPAR recycling and glutamate uncaging-induced structural and functional plasticity. Wild-type GRASP1, but not ID mutants, rescues spine loss in hippocampal CA1 neurons of Grasp1 knockout mice. Together, these results demonstrate a requirement for normal recycling endosome function in AMPAR-dependent synaptic function and neuronal connectivity in vivo, and suggest a potential role for GRASP1 in the pathophysiology of human cognitive disorders. PMID:28285821
A novel algorithm for fast grasping of unknown objects using C-shape configuration
NASA Astrophysics Data System (ADS)
Lei, Qujiang; Chen, Guangming; Meijer, Jonathan; Wisse, Martijn
2018-02-01
Increasing grasping efficiency is very important for the robots to grasp unknown objects especially subjected to unfamiliar environments. To achieve this, a new algorithm is proposed based on the C-shape configuration. Specifically, the geometric model of the used under-actuated gripper is approximated as a C-shape. To obtain an appropriate graspable position, this C-shape configuration is applied to fit geometric model of an unknown object. The geometric model of unknown object is constructed by using a single-view partial point cloud. To examine the algorithm using simulations, a comparison of the commonly used motion planners is made. The motion planner with the highest number of solved runs, lowest computing time and the shortest path length is chosen to execute grasps found by this grasping algorithm. The simulation results demonstrate that excellent grasping efficiency is achieved by adopting our algorithm. To validate this algorithm, experiment tests are carried out using a UR5 robot arm and an under-actuated gripper. The experimental results show that steady grasping actions are obtained. Hence, this research provides a novel algorithm for fast grasping of unknown objects.
Marangon, Mattia; Kubiak, Agnieszka; Króliczak, Gregory
2016-01-01
The neural bases of haptically-guided grasp planning and execution are largely unknown, especially for stimuli having no visual representations. Therefore, we used functional magnetic resonance imaging (fMRI) to monitor brain activity during haptic exploration of novel 3D complex objects, subsequent grasp planning, and the execution of the pre-planned grasps. Haptic object exploration, involving extraction of shape, orientation, and length of the to-be-grasped targets, was associated with the fronto-parietal, temporo-occipital, and insular cortex activity. Yet, only the anterior divisions of the posterior parietal cortex (PPC) of the right hemisphere were significantly more engaged in exploration of complex objects (vs. simple control disks). None of these regions were re-recruited during the planning phase. Even more surprisingly, the left-hemisphere intraparietal, temporal, and occipital areas that were significantly invoked for grasp planning did not show sensitivity to object features. Finally, grasp execution, involving the re-recruitment of the critical right-hemisphere PPC clusters, was also significantly associated with two kinds of bilateral parieto-frontal processes. The first represents transformations of grasp-relevant target features and is linked to the dorso-dorsal (lateral and medial) parieto-frontal networks. The second monitors grasp kinematics and belongs to the ventro-dorsal networks. Indeed, signal modulations associated with these distinct functions follow dorso-ventral gradients, with left aIPS showing significant sensitivity to both target features and the characteristics of the required grasp. Thus, our results from the haptic domain are consistent with the notion that the parietal processing for action guidance reflects primarily transformations from object-related to effector-related coding, and these mechanisms are rather independent of sensory input modality. PMID:26779002
Relevance of grasp types to assess functionality for personal autonomy.
Gracia-Ibáñez, Verónica; Sancho-Bru, Joaquin L; Vergara, Margarita
Cross-sectional research design. Current assessment of hand function is not focused on evaluating the real abilities required for autonomy. To quantify the relevance of grasp types for autonomy to guide hand recovery and its assessment. Representative tasks of the International Classification of Functioning, Disability and Health activities in which the hands are directly involved were recorded. The videos were analyzed to identify the grasps used with each hand, and their relevance for autonomy was determined by weighting time with the frequency of appearance of each activity in disability and dependency scales. Relevance is provided globally and distinguished by hand (right-left) and bimanual function. Significant differences in relevance are also checked. The most relevant grasps are pad-to-pad pinch (31.9%), lumbrical (15.4%), cylindrical (12%), and special pinch (7.3%) together with the nonprehensile (18.6%) use of the hand. Lumbrical grasp has higher relevance for the left hand (19.9% vs 12%) while cylindrical grasp for the right hand (15.3% vs 7.7%). Relevancies are also different depending on bimanual function. Different relative importance was obtained when considering dependency vs disability scales. Pad-to-pad pinch and nonprehensile grasp are the most relevant grasps for both hands, whereas lumbrical grasp is more relevant for the left hand and cylindrical grasp for the right one. The most significant difference in bimanual function refers to pad-to-pad pinch (more relevant for unimanual actions of the left hand and bimanual actions of the right). The relative importance of each grasp type for autonomy and the differences observed between hand and bimanual action should be used in medical and physical decision-making. N/A. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Marangon, Mattia; Kubiak, Agnieszka; Króliczak, Gregory
2015-01-01
The neural bases of haptically-guided grasp planning and execution are largely unknown, especially for stimuli having no visual representations. Therefore, we used functional magnetic resonance imaging (fMRI) to monitor brain activity during haptic exploration of novel 3D complex objects, subsequent grasp planning, and the execution of the pre-planned grasps. Haptic object exploration, involving extraction of shape, orientation, and length of the to-be-grasped targets, was associated with the fronto-parietal, temporo-occipital, and insular cortex activity. Yet, only the anterior divisions of the posterior parietal cortex (PPC) of the right hemisphere were significantly more engaged in exploration of complex objects (vs. simple control disks). None of these regions were re-recruited during the planning phase. Even more surprisingly, the left-hemisphere intraparietal, temporal, and occipital areas that were significantly invoked for grasp planning did not show sensitivity to object features. Finally, grasp execution, involving the re-recruitment of the critical right-hemisphere PPC clusters, was also significantly associated with two kinds of bilateral parieto-frontal processes. The first represents transformations of grasp-relevant target features and is linked to the dorso-dorsal (lateral and medial) parieto-frontal networks. The second monitors grasp kinematics and belongs to the ventro-dorsal networks. Indeed, signal modulations associated with these distinct functions follow dorso-ventral gradients, with left aIPS showing significant sensitivity to both target features and the characteristics of the required grasp. Thus, our results from the haptic domain are consistent with the notion that the parietal processing for action guidance reflects primarily transformations from object-related to effector-related coding, and these mechanisms are rather independent of sensory input modality.
Grasp-specific motor resonance is influenced by the visibility of the observed actor.
Bunday, Karen L; Lemon, Roger N; Kilner, James M; Davare, Marco; Orban, Guy A
2016-11-01
Motor resonance is the modulation of M1 corticospinal excitability induced by observation of others' actions. Recent brain imaging studies have revealed that viewing videos of grasping actions led to a differential activation of the ventral premotor cortex depending on whether the entire person is viewed versus only their disembodied hand. Here we used transcranial magnetic stimulation (TMS) to examine motor evoked potentials (MEPs) in the first dorsal interosseous (FDI) and abductor digiti minimi (ADM) during observation of videos or static images in which a whole person or merely the hand was seen reaching and grasping a peanut (precision grip) or an apple (whole hand grasp). Participants were presented with six visual conditions in which visual stimuli (video vs static image), view (whole person vs hand) and grasp (precision grip vs whole hand grasp) were varied in a 2 × 2 × 2 factorial design. Observing videos, but not static images, of a hand grasping different objects resulted in a grasp-specific interaction, such that FDI and ADM MEPs were differentially modulated depending on the type of grasp being observed (precision grip vs whole hand grasp). This interaction was present when observing the hand acting, but not when observing the whole person acting. Additional experiments revealed that these results were unlikely to be due to the relative size of the hand being observed. Our results suggest that observation of videos rather than static images is critical for motor resonance. Importantly, observing the whole person performing the action abolished the grasp-specific effect, which could be due to a variety of PMv inputs converging on M1. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Assessment of input-output properties and control of neuroprosthetic hand grasp.
Hines, A E; Owens, N E; Crago, P E
1992-06-01
Three tests have been developed to evaluate rapidly and quantitatively the input-output properties and patient control of neuroprosthetic hand grasp. Each test utilizes a visual pursuit tracking task during which the subject controls the grasp force and grasp opening (position) of the hand. The first test characterizes the static input-output properties of the hand grasp, where the input is a slowly changing patient generated command signal and the outputs are grasp force and grasp opening. Nonlinearities and inappropriate slopes have been documented in these relationships, and in some instances the need for system returning has been indicated. For each subject larger grasp forces were produced when grasping larger objects, and for some subjects the shapes of the relationships also varied with object size. The second test quantifies the ability of the subject to control the hand grasp outputs while tracking steps and ramps. Neuroprosthesis users had rms errors two to three times larger when tracking steps versus ramps, and had rms errors four to five times larger than normals when tracking ramps. The third test provides an estimate of the frequency response of the hand grasp system dynamics, from input and output data collected during a random tracking task. Transfer functions were estimated by spectral analysis after removal of the static input-output nonlinearities measured in the first test. The dynamics had low-pass filter characteristics with 3 dB cutoff frequencies from 1.0 to 1.4 Hz. The tests developed in this study provide a rapid evaluation of both the system and the user. They provide information to 1) help interpret subject performance of functional tasks, 2) evaluate the efficacy of system features such as closed-loop control, and 3) screen the neuroprosthesis to indicate the need for retuning.
Multidigit force control during unconstrained grasping in response to object perturbations
Haschke, Robert; Ritter, Helge; Santello, Marco; Ernst, Marc O.
2017-01-01
Because of the complex anatomy of the human hand, in the absence of external constraints, a large number of postures and force combinations can be used to attain a stable grasp. Motor synergies provide a viable strategy to solve this problem of motor redundancy. In this study, we exploited the technical advantages of an innovative sensorized object to study unconstrained hand grasping within the theoretical framework of motor synergies. Participants were required to grasp, lift, and hold the sensorized object. During the holding phase, we repetitively applied external disturbance forces and torques and recorded the spatiotemporal distribution of grip forces produced by each digit. We found that the time to reach the maximum grip force during each perturbation was roughly equal across fingers, consistent with a synchronous, synergistic stiffening across digits. We further evaluated this hypothesis by comparing the force distribution of human grasping vs. robotic grasping, where the control strategy was set by the experimenter. We controlled the global hand stiffness of the robotic hand and found that this control algorithm produced a force pattern qualitatively similar to human grasping performance. Our results suggest that the nervous system uses a default whole hand synergistic control to maintain a stable grasp regardless of the number of digits involved in the task, their position on the objects, and the type and frequency of external perturbations. NEW & NOTEWORTHY We studied hand grasping using a sensorized object allowing unconstrained finger placement. During object perturbation, the time to reach the peak force was roughly equal across fingers, consistently with a synergistic stiffening across fingers. Force distribution of a robotic grasping hand, where the control algorithm is based on global hand stiffness, was qualitatively similar to human grasping. This suggests that the central nervous system uses a default whole hand synergistic control to maintain a stable grasp. PMID:28228582
Kuntz, Jessica R; Karl, Jenni M; Doan, Jon B; Whishaw, Ian Q
2018-04-01
Reach-to-grasp movements feature the integration of a reach directed by the extrinsic (location) features of a target and a grasp directed by the intrinsic (size, shape) features of a target. The action-perception theory suggests that integration and scaling of a reach-to-grasp movement, including its trajectory and the concurrent digit shaping, are features that depend upon online action pathways of the dorsal visuomotor stream. Scaling is much less accurate for a pantomime reach-to-grasp movement, a pretend reach with the target object absent. Thus, the action-perception theory proposes that pantomime movement is mediated by perceptual pathways of the ventral visuomotor stream. A distinguishing visual feature of a real reach-to-grasp movement is gaze anchoring, in which a participant visually fixates the target throughout the reach and disengages, often by blinking or looking away/averting the head, at about the time that the target is grasped. The present study examined whether gaze anchoring is associated with pantomime reaching. The eye and hand movements of participants were recorded as they reached for a ball of one of three sizes, located on a pedestal at arms' length, or pantomimed the same reach with the ball and pedestal absent. The kinematic measures for real reach-to-grasp movements were coupled to the location and size of the target, whereas the kinematic measures for pantomime reach-to-grasp, although grossly reflecting target features, were significantly altered. Gaze anchoring was also tightly coupled to the target for real reach-to-grasp movements, but there was no systematic focus for gaze, either in relation with the virtual target, the previous location of the target, or the participant's reaching hand, for pantomime reach-to-grasp. The presence of gaze anchoring during real vs. its absence in pantomime reach-to-grasp supports the action-perception theory that real, but not pantomime, reaches are online visuomotor actions and is discussed in relation with the neural control of real and pantomime reach-to-grasp movements.
Geed, Shashwati; McCurdy, Martha L.; van Kan, Peter L. E.
2017-01-01
Coordinated reach-to-grasp movements require precise spatiotemporal synchrony between proximal forelimb muscles (shoulder, elbow) that transport the hand toward a target during reach, and distal muscles (wrist, digit) that simultaneously preshape and orient the hand for grasp. The precise mechanisms through which the redundant neuromuscular circuitry coordinates reach with grasp, however, remain unclear. Recently, Geed and Van Kan (2016) demonstrated, using exploratory factor analysis (EFA), that limited numbers of global, template-like transport/preshape- and grasp-related muscle components underlie the complexity and variability of intramuscular electromyograms (EMGs) of up to 21 distal and proximal muscles recorded while monkeys performed reach-to-grasp tasks. Importantly, transport/preshape- and grasp-related muscle components showed invariant spatiotemporal coupling, which provides a potential mechanism for coordinating forelimb muscles during reach-to-grasp movements. In the present study, we tested whether ensemble discharges of forelimb neurons in the cerebellar nucleus interpositus (NI) and its target, the magnocellular red nucleus (RNm), a source of rubrospinal fibers, function as neuronal correlates of the transport/preshape- and grasp-related muscle components we identified. EFA applied to single-unit discharges of populations of NI and RNm neurons recorded while the same monkeys that were used previously performed the same reach-to-grasp tasks, revealed neuronal components in the ensemble discharges of both NI and RNm neuronal populations with characteristics broadly similar to muscle components. Subsets of NI and RNm neuronal components were strongly and significantly crosscorrelated with subsets of muscle components, suggesting that similar functional units of reach-to-grasp behavior are expressed by NI and RNm neuronal populations and forelimb muscles. Importantly, like transport/preshape- and grasp-related muscle components, their NI and RNm neuronal correlates showed invariant spatiotemporal coupling. Clinical and lesion studies have reported disruption of coupling between reach and grasp following cerebellar damage; the present results expand on those studies by identifying a neuronal mechanism that may underlie cerebellar contributions to spatiotemporal coordination of distal and proximal limb muscles during reaching to grasp. We conclude that finding similar functional units of behavior expressed at multiple levels of information processing along interposito-rubrospinal pathways and forelimb muscles supports the hypothesis that functionally related populations of NI and RNm neurons act synergistically in the control of complex coordinated motor behaviors. PMID:28270752
Miyazaki, Takaaki; Lin, Tzu-Yang; Ito, Kei; Lee, Chi-Hon; Stopfer, Mark
2016-01-01
Although the gustatory system provides animals with sensory cues important for food choice and other critical behaviors, little is known about neural circuitry immediately following gustatory sensory neurons (GSNs). Here, we identify and characterize a bilateral pair of gustatory second-order neurons in Drosophila. Previous studies identified GSNs that relay taste information to distinct subregions of the primary gustatory center (PGC) in the gnathal ganglia (GNG). To identify candidate gustatory second-order neurons (G2Ns) we screened ~5,000 GAL4 driver strains for lines that label neural fibers innervating the PGC. We then combined GRASP (GFP reconstitution across synaptic partners) with presynaptic labeling to visualize potential synaptic contacts between the dendrites of the candidate G2Ns and the axonal terminals of Gr5a-expressing GSNs, which are known to respond to sucrose. Results of the GRASP analysis, followed by a single cell analysis by FLPout recombination, revealed a pair of neurons that contact Gr5a axon terminals in both brain hemispheres, and send axonal arborizations to a distinct region outside the PGC but within the GNG. To characterize the input and output branches, respectively, we expressed fluorescence-tagged acetylcholine receptor subunit (Dα7) and active-zone marker (Brp) in the G2Ns. We found that G2N input sites overlaid GRASP-labeled synaptic contacts to Gr5a neurons, while presynaptic sites were broadly distributed throughout the neurons’ arborizations. GRASP analysis and further tests with the Syb-GRASP method suggested that the identified G2Ns receive synaptic inputs from Gr5a-expressing GSNs, but not Gr66a-expressing GSNs, which respond to caffeine. The identified G2Ns relay information from Gr5a-expressing GSNs to distinct regions in the GNG, and are distinct from other, recently identified gustatory projection neurons, which relay information about sugars to a brain region called the antennal mechanosensory and motor center (AMMC). Our findings suggest unexpected complexity for taste information processing in the first relay of the gustatory system. PMID:26004543
Miyazaki, Takaaki; Lin, Tzu-Yang; Ito, Kei; Lee, Chi-Hon; Stopfer, Mark
2015-01-01
Although the gustatory system provides animals with sensory cues important for food choice and other critical behaviors, little is known about neural circuitry immediately following gustatory sensory neurons (GSNs). Here, we identify and characterize a bilateral pair of gustatory second-order neurons (G2Ns) in Drosophila. Previous studies identified GSNs that relay taste information to distinct subregions of the primary gustatory center (PGC) in the gnathal ganglia (GNG). To identify candidate G2Ns, we screened ∼5,000 GAL4 driver strains for lines that label neural fibers innervating the PGC. We then combined GRASP (GFP reconstitution across synaptic partners) with presynaptic labeling to visualize potential synaptic contacts between the dendrites of the candidate G2Ns and the axonal terminals of Gr5a-expressing GSNs, which are known to respond to sucrose. Results of the GRASP analysis, followed by a single-cell analysis by FLP-out recombination, revealed a pair of neurons that contact Gr5a axon terminals in both brain hemispheres and send axonal arborizations to a distinct region outside the PGC but within the GNG. To characterize the input and output branches, respectively, we expressed fluorescence-tagged acetylcholine receptor subunit (Dα7) and active-zone marker (Brp) in the G2Ns. We found that G2N input sites overlaid GRASP-labeled synaptic contacts to Gr5a neurons, while presynaptic sites were broadly distributed throughout the neurons' arborizations. GRASP analysis and further tests with the Syb-GRASP method suggested that the identified G2Ns receive synaptic inputs from Gr5a-expressing GSNs, but not Gr66a-expressing GSNs, which respond to caffeine. The identified G2Ns relay information from Gr5a-expressing GSNs to distinct regions in the GNG, and are distinct from other, recently identified gustatory projection neurons, which relay information about sugars to a brain region called the antennal mechanosensory and motor center (AMMC). Our findings suggest unexpected complexity for taste information processing in the first relay of the gustatory system.
Reversible grasp reflexes in normal pressure hydrocephalus.
Thomas, Rhys H; Bennetto, Luke; Silva, Mark T
2009-05-01
We present two cases of normal pressure hydrocephalus in combination with grasp reflexes. In both cases the grasp reflexes disappeared following high volume cerebrospinal fluid removal. In one of the cases the grasp reflexes returned over a period of weeks but again resolved following definitive cerebrospinal fluid shunting surgery, and remained absent until final follow up at 9 months. We hypothesise that resolving grasp reflexes following high volume CSF removal has both diagnostic and prognostic value in normal pressure hydrocephalus, encouraging larger studies on the relevance of primitive reflexes in NPH.
Grasp Assist Device with Automatic Mode Control Logic
NASA Technical Reports Server (NTRS)
Laske, Evan (Inventor); Davis, Donald R. (Inventor); Ihrke, Chris A. (Inventor)
2018-01-01
A system includes a glove, sensors, actuator assemblies, and controller. The sensors include load sensors which measure an actual grasping force and attitude sensors which determine a glove attitude. The actuator assembly provides a grasp assist force to the glove. Respective locations of work cells in the work environment and permitted work tasks for each work cell are programmed into the controller. The controller detects the glove location and attitude. A work task is selected by the controller for the location. The controller calculates a required grasp assist force using measured actual grasping forces from the load sensors. The required grasp assist force is applied via the glove using the actuator assembly to thereby assist the operator in performing the identified work task.
Autonomous Object Manipulation Using a Soft Planar Grasping Manipulator
Katzschmann, Robert K.; Marchese, Andrew D.
2015-01-01
Abstract This article presents the development of an autonomous motion planning algorithm for a soft planar grasping manipulator capable of grasp-and-place operations by encapsulation with uncertainty in the position and shape of the object. The end effector of the soft manipulator is fabricated in one piece without weakening seams using lost-wax casting instead of the commonly used multilayer lamination process. The soft manipulation system can grasp randomly positioned objects within its reachable envelope and move them to a desired location without human intervention. The autonomous planning system leverages the compliance and continuum bending of the soft grasping manipulator to achieve repeatable grasps in the presence of uncertainty. A suite of experiments is presented that demonstrates the system's capabilities. PMID:27625916
Scaling analysis and SE simulation of the tilted cylinder-interface capillary interaction
NASA Astrophysics Data System (ADS)
Gao, S. Q.; Zhang, X. Y.; Zhou, Y. H.
2018-06-01
The capillary interaction induced by a tilted cylinder and interface is the basic configuration of many complex systems, such as micro-pillar arrays clustering, super-hydrophobicity of hairy surface, water-walking insects, and fiber aggregation. We systematically analyzed the scaling laws of tilt angle, contact angle, and cylinder radius on the contact line shape by SE simulation and experiment. The following in-depth analysis of the characteristic parameters (shift, stretch and distortion) of the deformed contact lines reveals the self-similar shape of contact line. Then a general capillary force scaling law is proposed to incredibly grasp all the simulated and experimental data by a quite straightforward ellipse approximation approach.
A soft-contact model for computing safety margins in human prehension.
Singh, Tarkeshwar; Ambike, Satyajit
2017-10-01
The soft human digit tip forms contact with grasped objects over a finite area and applies a moment about an axis normal to the area. These moments are important for ensuring stability during precision grasping. However, the contribution of these moments to grasp stability is rarely investigated in prehension studies. The more popular hard-contact model assumes that the digits exert a force vector but no free moment on the grasped object. Many sensorimotor studies use this model and show that humans estimate friction coefficients to scale the normal force to grasp objects stably, i.e. the smoother the surface, the tighter the grasp. The difference between the applied normal force and the minimal normal force needed to prevent slipping is called safety margin and this index is widely used as a measure of grasp planning. Here, we define and quantify safety margin using a more realistic contact model that allows digits to apply both forces and moments. Specifically, we adapt a soft-contact model from robotics and demonstrate that the safety margin thus computed is a more accurate and robust index of grasp planning than its hard-contact variant. Previously, we have used the soft-contact model to propose two indices of grasp planning that show how humans account for the shape and inertial properties of an object. A soft-contact based safety margin offers complementary insights by quantifying how humans may account for surface properties of the object and skin tissue during grasp planning and execution. Copyright © 2017 Elsevier B.V. All rights reserved.
Unusual hand postures but not familiar tools show motor equivalence with precision grasping.
Tang, Rixin; Whitwell, Robert L; Goodale, Melvyn A
2016-06-01
A central question in sensorimotor control is whether or not actions performed with the hands and corresponding actions performed with tools share a common underlying motor plan, even though different muscles and effectors are engaged. There is certainly evidence that tools used to extend the reach of the limb can be incorporated into the body schema after training. But even so, it is not clear whether or not actions such as grasping with tools and grasping with the fingers share the same programming network, i.e. show 'motor equivalence'. Here we first show that feedback-appropriate motor programming for grasps with atypical hand postures readily transfers to stereotypical precision grasps. In stark contrast, however, we find no evidence for an analogous transfer of the programming for grasps using tools to the same stereotypical precision grasps. These findings have important implications for our understanding of body schema. Although the extension of the limb that is afforded by tool use may be incorporated into the body schema, the programming of a grasping movement made with tools appears to resist such incorporation. It could be the case that the proprioceptive signals from the limb can be easily updated to reflect the end of a tool held in the hand, but the motor programs and sensory signals associated with grasping with the thumb and finger cannot be easily adapted to control the opening and closing of a tool. Instead, new but well-practiced motor programs are put in place for tool use that do not exhibit motor equivalence with manual grasping. Copyright © 2016 Elsevier B.V. All rights reserved.
A force vector and surface orientation sensor for intelligent grasping
NASA Technical Reports Server (NTRS)
Mcglasson, W. D.; Lorenz, R. D.; Duffie, N. A.; Gale, K. L.
1991-01-01
The paper discusses a force vector and surface orientation sensor suitable for intelligent grasping. The use of a novel four degree-of-freedom force vector robotic fingertip sensor allows efficient, real time intelligent grasping operations. The basis of sensing for intelligent grasping operations is presented and experimental results demonstrate the accuracy and ease of implementation of this approach.
Grasps Recognition and Evaluation of Stroke Patients for Supporting Rehabilitation Therapy
Sale, Patrizio; Nijenhuis, Sharon; Prange, Gerdienke; Amirabdollahian, Farshid
2014-01-01
Stroke survivors often suffer impairments on their wrist and hand. Robot-mediated rehabilitation techniques have been proposed as a way to enhance conventional therapy, based on intensive repeated movements. Amongst the set of activities of daily living, grasping is one of the most recurrent. Our aim is to incorporate the detection of grasps in the machine-mediated rehabilitation framework so that they can be incorporated into interactive therapeutic games. In this study, we developed and tested a method based on support vector machines for recognizing various grasp postures wearing a passive exoskeleton for hand and wrist rehabilitation after stroke. The experiment was conducted with ten healthy subjects and eight stroke patients performing the grasping gestures. The method was tested in terms of accuracy and robustness with respect to intersubjects' variability and differences between different grasps. Our results show reliable recognition while also indicating that the recognition accuracy can be used to assess the patients' ability to consistently repeat the gestures. Additionally, a grasp quality measure was proposed to measure the capabilities of the stroke patients to perform grasp postures in a similar way than healthy people. These two measures can be potentially used as complementary measures to other upper limb motion tests. PMID:25258709
Nelissen, Koen; Vanduffel, Wim
2017-11-08
The ability to recognize others' actions is an important aspect of social behavior. While neurophysiological and behavioral research in monkeys has offered a better understanding of how the primate brain processes this type of information, further insight with respect to the neural correlates of action recognition requires tasks that allow recording of brain activity or perturbing brain regions while monkeys simultaneously make behavioral judgements about certain aspects of observed actions. Here we investigated whether rhesus monkeys could actively discriminate videos showing grasping or non-grasping manual motor acts in a two-alternative categorization task. After monkeys became proficient in this task, we tested their ability to generalize to a number of untrained, novel videos depicting grasps or other manual motor acts. Monkeys generalized to a wide range of novel human or conspecific grasping and non-grasping motor acts. They failed, however, for videos showing unfamiliar actions such as a non-biological effector performing a grasp, or a human hand touching an object with the back of the hand. This study shows the feasibility of training monkeys to perform active judgements about certain aspects of observed actions, instrumental for causal investigations into the neural correlates of action recognition.
A novel cluster-tube self-adaptive robot hand.
Fu, Hong; Yang, Haokun; Song, Weishu; Zhang, Wenzeng
2017-01-01
This paper proposes a novel cluster-tube self-adaptive robot hand (CTSA Hand). The CTSA Hand consists of a base, a motor, a transmission mechanism, multiple elastic tendons, and a group of sliding-tube assemblies. Each sliding-tube assembly is composed of a sliding tube, a guide rod, two springs and a hinge. When the hand grasping an object, the object pushes some sliding tubes to different positions according to the surface shape of the object, the motor pulls the tendons tight to cluster tubes. The CTSA Hand can realize self-adaptive grasping of objects of different sizes and shapes. The CTSA Hand can grasp multiple objects simultaneously because the grasping of the hand acts as many grippers in different directions and heights. The grasping forces of the hand are adjusted by a closed-loop control system with potentiometer. Experimental results show that the CTSA Hand has the features of highly self-adaption and large grasping forces when grasping various objects.
Comparisons among tools, surface orientation, and pencil grasp for children 23 months of age.
Yakimishyn, Janet E; Magill-Evans, Joyce
2002-01-01
The purpose of this study was to determine whether writing tool type and angle of writing surface affect grasp. Fifty-one children 23 to 24 months of age who were typically developing drew with a primary marker, colored pencil, and small piece of crayon on a table and an easel. The marker and pencil were presented pointing left, right, and toward the child. The order of writing tool presentation was counterbalanced. Grasps were scored with a 5-point rating system and analyzed with dependent t tests. Children used a more mature grasp when drawing with a piece of crayon than with a pencil. No difference in grasp maturity was found when using a pencil compared with a marker. A more mature grasp when drawing on the easel compared with the table was used with the crayon but not with the marker or pencil. Results imply that a short writing tool combined with a vertical surface can influence the grasp of young children.
Representation of grasp postures and anticipatory motor planning in children.
Stöckel, Tino; Hughes, Charmayne M L; Schack, Thomas
2012-11-01
In this study, we investigated anticipatory motor planning and the development of cognitive representation of grasp postures in children aged 7, 8, and 9 years. Overall, 9-year-old children were more likely to plan their movements to end in comfortable postures, and have distinct representational structures of certain grasp postures, compared to the 7- and 8-year old children. Additionally, the sensitivity toward comfortable end-states (end-state comfort) was related to the mental representation of certain grasp postures. Children with grasp comfort related and functionally well-structured representations were more likely to have satisfied end-state comfort in both the simple and the advanced planning condition. In contrast, end-state comfort satisfaction for the advanced planning condition was much lower for children whose cognitive representations were not structured by grasp comfort. The results of the present study support the notion that cognitive action representation plays an important role in the planning and control of grasp postures.
Human grasping database for activities of daily living with depth, color and kinematic data streams.
Saudabayev, Artur; Rysbek, Zhanibek; Khassenova, Raykhan; Varol, Huseyin Atakan
2018-05-29
This paper presents a grasping database collected from multiple human subjects for activities of daily living in unstructured environments. The main strength of this database is the use of three different sensing modalities: color images from a head-mounted action camera, distance data from a depth sensor on the dominant arm and upper body kinematic data acquired from an inertial motion capture suit. 3826 grasps were identified in the data collected during 9-hours of experiments. The grasps were grouped according to a hierarchical taxonomy into 35 different grasp types. The database contains information related to each grasp and associated sensor data acquired from the three sensor modalities. We also provide our data annotation software written in Matlab as an open-source tool. The size of the database is 172 GB. We believe this database can be used as a stepping stone to develop big data and machine learning techniques for grasping and manipulation with potential applications in rehabilitation robotics and intelligent automation.
Action observation circuits in the macaque monkey cortex.
Nelissen, Koen; Borra, Elena; Gerbella, Marzio; Rozzi, Stefano; Luppino, Giuseppe; Vanduffel, Wim; Rizzolatti, Giacomo; Orban, Guy A
2011-03-09
In both monkeys and humans, the observation of actions performed by others activates cortical motor areas. An unresolved question concerns the pathways through which motor areas receive visual information describing motor acts. Using functional magnetic resonance imaging (fMRI), we mapped the macaque brain regions activated during the observation of grasping actions, focusing on the superior temporal sulcus region (STS) and the posterior parietal lobe. Monkeys viewed either videos with only the grasping hand visible or videos with the whole actor visible. Observation of both types of grasping videos activated elongated regions in the depths of both lower and upper banks of STS, as well as parietal areas PFG and anterior intraparietal (AIP). The correlation of fMRI data with connectional data showed that visual action information, encoded in the STS, is forwarded to ventral premotor cortex (F5) along two distinct functional routes. One route connects the upper bank of the STS with area PFG, which projects, in turn, to the premotor area F5c. The other connects the anterior part of the lower bank of the STS with premotor areas F5a/p via AIP. Whereas the first functional route emphasizes the agent and may relay visual information to the parieto-frontal mirror circuit involved in understanding the agent's intentions, the second route emphasizes the object of the action and may aid in understanding motor acts with respect to their immediate goal.
A Biologically Inspired Learning to Grasp System
2001-10-25
possible extensive discussions of data on the premotor cortex and monkey grasping circuit with Giacomo Rizzolatti , Vittorio Gallese, to whom we express...premotor specialisation for the different types of grasps that Rizzolatti group [3] has found be formed at this age yet. Infants will need to...our gratitude. REFERENCES [1] M. Jeannerod, M.A. Arbib, G. Rizzolatti , H. Sakata, “Grasping objects: the cortical mechanisms of visuomotor
NASA Technical Reports Server (NTRS)
Wilcox, Brian H.; Tso, Kam S.; Litwin, Todd E.; Hayati, Samad A.; Bon, Bruce B.
1991-01-01
Experimental robotic system semiautomatically grasps rotating object, stops rotation, and pulls object to rest in fixture. Based on combination of advanced techniques for sensing and control, constructed to test concepts for robotic recapture of spinning artificial satellites. Potential terrestrial applications for technology developed with help of system includes tracking and grasping of industrial parts on conveyor belts, tracking of vehicles and animals, and soft grasping of moving objects in general.
Maximum Grasping Reach of Operators Possessing Functional Impairments of the Upper Extremities.
1978-12-01
ADDRESS 10. PROGRAM ELEMENT, PROJECT, TASK AFITStudent at: Texas A&M University AREA & WORK UNIT NUMBERS II. CONTROLLING OFFICENA E AND AD_. . 12...RELEASE AFR 190.172 Ja e I 10, t USAF 23 SEP 1980 , ’ 1"lic Aar* e IS. SUPPLEMENTARY NOTES Approved for public release; IAW AFR 190-17 Air Force...C .. .... ..... ..... .... 141 APPENDIX D .. ... ...... ..... .... 184 APPENDIX E .. ... ..... ...... .... 187 APPENDIX F .. .... ..... ..... .... 189
The extended object-grasping network.
Gerbella, Marzio; Rozzi, Stefano; Rizzolatti, Giacomo
2017-10-01
Grasping is the most important skilled motor act of primates. It is based on a series of sensorimotor transformations through which the affordances of the objects to be grasped are transformed into appropriate hand movements. It is generally accepted that a circuit formed by inferior parietal areas AIP and PFG and ventral premotor area F5 represents the core circuit for sensorimotor transformations for grasping. However, selection and control of appropriate grip should also depend on higher-order information, such as the meaning of the object to be grasped, and the overarching goal of the action in which grasping is embedded. In this review, we describe recent findings showing that specific sectors of the ventrolateral prefrontal cortex are instrumental in controlling higher-order aspects of grasping. We show that these prefrontal sectors control the premotor cortex through two main gateways: the anterior subdivision of ventral area F5-sub-area F5a-, and the pre-supplementary area (area F6). We then review functional studies showing that both F5a and F6, besides being relay stations of prefrontal information, also play specific roles in grasping. Namely, sub-area F5a is involved in stereoscopic analysis of 3D objects, and in planning cue-dependent grasping activity. As for area F6, this area appears to play a crucial role in determining when to execute the motor program encoded in the parieto-premotor circuit. The recent discovery that area F6 contains a set of neurons encoding specific grip types suggests that this area, besides controlling "when to go", also may control the grip type, i.e., "how to go". We conclude by discussing clinical syndromes affecting grasping actions and their possible mechanisms.
A Novel Device for Grasping Assessment during Functional Tasks: Preliminary Results
Rocha, Ana Carolinne Portela; Tudella, Eloisa; Pedro, Leonardo M.; Appel, Viviane Cristina Roma; da Silva, Louise Gracelli Pereira; Caurin, Glauco Augusto de Paula
2016-01-01
This paper presents a methodology and first results obtained in a study with a novel device that allows the analysis of grasping quality. Such a device is able to acquire motion information of upper limbs allowing kinetic of manipulation analysis as well. A pilot experiment was carried out with six groups of typically developing children aged between 5 and 10 years, with seven to eight children in each one. The device, designed to emulate a glass, has an optical system composed by one digital camera and a special convex mirror that together allow image acquisition of grasping hand posture when it is grasped and manipulated. It also carries an Inertial Measurement Unit that captures motion data as acceleration, orientation, and angular velocities. The novel instrumented object is used in our approach to evaluate functional tasks performance in quantitative terms. During tests, each child was invited to grasp the cylindrical part of the device that was placed on the top of a table, simulating the task of drinking a glass of water. In the sequence, the child was oriented to transport the device back to the starting position and release it. The task was repeated three times for each child. A grasping hand posture evaluation is presented as an example to evaluate grasping quality. Additionally, motion patterns obtained with the trials performed with the different groups are presented and discussed. This device is attractive due to its portable characteristics, the small size, and its ability to evaluate grasping form. The results may be also useful to analyze the evolution of the rehabilitation process through reach-to-grasping movement and the grasping images analysis. PMID:26942178
Responses of mirror neurons in area F5 to hand and tool grasping observation
Rochat, Magali J.; Caruana, Fausto; Jezzini, Ahmad; Escola, Ludovic; Intskirveli, Irakli; Grammont, Franck; Gallese, Vittorio; Rizzolatti, Giacomo
2010-01-01
Mirror neurons are a distinct class of neurons that discharge both during the execution of a motor act and during observation of the same or similar motor act performed by another individual. However, the extent to which mirror neurons coding a motor act with a specific goal (e.g., grasping) might also respond to the observation of a motor act having the same goal, but achieved with artificial effectors, is not yet established. In the present study, we addressed this issue by recording mirror neurons from the ventral premotor cortex (area F5) of two monkeys trained to grasp objects with pliers. Neuron activity was recorded during the observation and execution of grasping performed with the hand, with pliers and during observation of an experimenter spearing food with a stick. The results showed that virtually all neurons responding to the observation of hand grasping also responded to the observation of grasping with pliers and, many of them to the observation of spearing with a stick. However, the intensity and pattern of the response differed among conditions. Hand grasping observation determined the earliest and the strongest discharge, while pliers grasping and spearing observation triggered weaker responses at longer latencies. We conclude that F5 grasping mirror neurons respond to the observation of a family of stimuli leading to the same goal. However, the response pattern depends upon the similarity between the observed motor act and the one executed by the hand, the natural motor template. PMID:20577726
Development of infrared scene projectors for testing fire-fighter cameras
NASA Astrophysics Data System (ADS)
Neira, Jorge E.; Rice, Joseph P.; Amon, Francine K.
2008-04-01
We have developed two types of infrared scene projectors for hardware-in-the-loop testing of thermal imaging cameras such as those used by fire-fighters. In one, direct projection, images are projected directly into the camera. In the other, indirect projection, images are projected onto a diffuse screen, which is then viewed by the camera. Both projectors use a digital micromirror array as the spatial light modulator, in the form of a Micromirror Array Projection System (MAPS) engine having resolution of 800 x 600 with mirrors on a 17 micrometer pitch, aluminum-coated mirrors, and a ZnSe protective window. Fire-fighter cameras are often based upon uncooled microbolometer arrays and typically have resolutions of 320 x 240 or lower. For direct projection, we use an argon-arc source, which provides spectral radiance equivalent to a 10,000 Kelvin blackbody over the 7 micrometer to 14 micrometer wavelength range, to illuminate the micromirror array. For indirect projection, an expanded 4 watt CO II laser beam at a wavelength of 10.6 micrometers illuminates the micromirror array and the scene formed by the first-order diffracted light from the array is projected onto a diffuse aluminum screen. In both projectors, a well-calibrated reference camera is used to provide non-uniformity correction and brightness calibration of the projected scenes, and the fire-fighter cameras alternately view the same scenes. In this paper, we compare the two methods for this application and report on our quantitative results. Indirect projection has an advantage of being able to more easily fill the wide field of view of the fire-fighter cameras, which typically is about 50 degrees. Direct projection more efficiently utilizes the available light, which will become important in emerging multispectral and hyperspectral applications.
Liu, Tao; Guo, Yin; Yang, Shourui; Yin, Shibin; Zhu, Jigui
2017-01-01
Industrial robots are expected to undertake ever more advanced tasks in the modern manufacturing industry, such as intelligent grasping, in which robots should be capable of recognizing the position and orientation of a part before grasping it. In this paper, a monocular-based 6-degree of freedom (DOF) pose estimation technology to enable robots to grasp large-size parts at informal poses is proposed. A camera was mounted on the robot end-flange and oriented to measure several featured points on the part before the robot moved to grasp it. In order to estimate the part pose, a nonlinear optimization model based on the camera object space collinearity error in different poses is established, and the initial iteration value is estimated with the differential transformation. Measuring poses of the camera are optimized based on uncertainty analysis. Also, the principle of the robotic intelligent grasping system was developed, with which the robot could adjust its pose to grasp the part. In experimental tests, the part poses estimated with the method described in this paper were compared with those produced by a laser tracker, and results show the RMS angle and position error are about 0.0228° and 0.4603 mm. Robotic intelligent grasping tests were also successfully performed in the experiments. PMID:28216555
Liu, Tao; Guo, Yin; Yang, Shourui; Yin, Shibin; Zhu, Jigui
2017-02-14
Industrial robots are expected to undertake ever more advanced tasks in the modern manufacturing industry, such as intelligent grasping, in which robots should be capable of recognizing the position and orientation of a part before grasping it. In this paper, a monocular-based 6-degree of freedom (DOF) pose estimation technology to enable robots to grasp large-size parts at informal poses is proposed. A camera was mounted on the robot end-flange and oriented to measure several featured points on the part before the robot moved to grasp it. In order to estimate the part pose, a nonlinear optimization model based on the camera object space collinearity error in different poses is established, and the initial iteration value is estimated with the differential transformation. Measuring poses of the camera are optimized based on uncertainty analysis. Also, the principle of the robotic intelligent grasping system was developed, with which the robot could adjust its pose to grasp the part. In experimental tests, the part poses estimated with the method described in this paper were compared with those produced by a laser tracker, and results show the RMS angle and position error are about 0.0228° and 0.4603 mm. Robotic intelligent grasping tests were also successfully performed in the experiments.
de Clauser, Larissa; Kasper, Hansjörg; Schwab, Martin E.
2016-01-01
Motor skills represent high-precision movements performed at optimal speed and accuracy. Such motor skills are learned with practice over time. Besides practice, effects of motivation have also been shown to influence speed and accuracy of movements, suggesting that fast movements are performed to maximize gained reward over time as noted in previous studies. In rodents, skilled motor performance has been successfully modeled with the skilled grasping task, in which animals use their forepaw to grasp for sugar pellet rewards through a narrow window. Using sugar pellets, the skilled grasping task is inherently tied to motivation processes. In the present study, we performed three experiments modulating animals’ motivation during skilled grasping by changing the motivational state, presenting different reward value ratios, and displaying Pavlovian stimuli. We found in all three studies that motivation affected the speed of skilled grasping movements, with the strongest effects seen due to motivational state and reward value. Furthermore, accuracy of the movement, measured in success rate, showed a strong dependence on motivational state as well. Pavlovian cues had only minor effects on skilled grasping, but results indicate an inverse Pavlovian-instrumental transfer effect on movement speed. These findings have broad implications considering the increasing use of skilled grasping in studies of motor system structure, function, and recovery after injuries. PMID:27194796
Photoacoustic projection imaging using an all-optical detector array
NASA Astrophysics Data System (ADS)
Bauer-Marschallinger, J.; Felbermayer, K.; Berer, T.
2018-02-01
We present a prototype for all-optical photoacoustic projection imaging. By generating projection images, photoacoustic information of large volumes can be retrieved with less effort compared to common photoacoustic computed tomography where many detectors and/or multiple measurements are required. In our approach, an array of 60 integrating line detectors is used to acquire photoacoustic waves. The line detector array consists of fiber-optic MachZehnder interferometers, distributed on a cylindrical surface. From the measured variation of the optical path lengths of the interferometers, induced by photoacoustic waves, a photoacoustic projection image can be reconstructed. The resulting images represent the projection of the three-dimensional spatial light absorbance within the imaged object onto a two-dimensional plane, perpendicular to the line detector array. The fiber-optic detectors achieve a noise-equivalent pressure of 24 Pascal at a 10 MHz bandwidth. We present the operational principle, the structure of the array, and resulting images. The system can acquire high-resolution projection images of large volumes within a short period of time. Imaging large volumes at high frame rates facilitates monitoring of dynamic processes.
BRDF-dependent accuracy of array-projection-based 3D sensors.
Heist, Stefan; Kühmstedt, Peter; Tünnermann, Andreas; Notni, Gunther
2017-03-10
In order to perform high-speed three-dimensional (3D) shape measurements with structured light systems, high-speed projectors are required. One possibility is an array projector, which allows pattern projection at several tens of kilohertz by switching on and off the LEDs of various slide projectors. The different projection centers require a separate analysis, as the intensity received by the cameras depends on the projection direction and the object's bidirectional reflectance distribution function (BRDF). In this contribution, we investigate the BRDF-dependent errors of array-projection-based 3D sensors and propose an error compensation process.
Dikin-type algorithms for dextrous grasping force optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buss, M.; Faybusovich, L.; Moore, J.B.
1998-08-01
One of the central issues in dextrous robotic hand grasping is to balance external forces acting on the object and at the same time achieve grasp stability and minimum grasping effort. A companion paper shows that the nonlinear friction-force limit constraints on grasping forces are equivalent to the positive definiteness of a certain matrix subject to linear constraints. Further, compensation of the external object force is also a linear constraint on this matrix. Consequently, the task of grasping force optimization can be formulated as a problem with semidefinite constraints. In this paper, two versions of strictly convex cost functions, onemore » of them self-concordant, are considered. These are twice-continuously differentiable functions that tend to infinity at the boundary of possible definiteness. For the general class of such cost functions, Dikin-type algorithms are presented. It is shown that the proposed algorithms guarantee convergence to the unique solution of the semidefinite programming problem associated with dextrous grasping force optimization. Numerical examples demonstrate the simplicity of implementation, the good numerical properties, and the optimality of the approach.« less
Leeb, Robert; Gubler, Miguel; Tavella, Michele; Miller, Heather; Del Millan, Jose R
2010-01-01
To patients who have lost the functionality of their hands as a result of a severe spinal cord injury or brain stroke, the development of new techniques for grasping is indispensable for reintegration and independency in daily life. Functional Electrical Stimulation (FES) of residual muscles can reproduce the most dominant grasping tasks and can be initialized by brain signals. However, due to the very complex hand anatomy and current limitations in FES-technology with surface electrodes, these grasp patterns cannot be smoothly executed. In this paper, we present an adaptable passive hand orthosis which is capable of producing natural and smooth movements when coupled with FES. It evenly synchronizes the grasping movements and applied forces on all fingers, allowing for naturalistic gestures and functional grasps of everyday objects. The orthosis is also equipped with a lock, which allows it to remain in the desired position without the need for long-term stimulation. Furthermore, we quantify improvements offered by the orthosis compare them with natural grasps on healthy subjects.
Low-cost solar array project and Proceedings of the 15th Project Integration Meeting
NASA Technical Reports Server (NTRS)
1980-01-01
Progress made by the Low-Cost Solar Array Project during the period December 1979 to April 1980 is described. Project analysis and integration, technology development in silicon material, large area silicon sheet and encapsulation, production process and equipment development, engineering, and operation are included.
Orientation priming of grasping decision for drawings of objects and blocks, and words.
Chainay, Hanna; Naouri, Lucie; Pavec, Alice
2011-05-01
This study tested the influence of orientation priming on grasping decisions. Two groups of 20 healthy participants had to select a preferred grasping orientation (horizontal, vertical) based on drawings of everyday objects, geometric blocks or object names. Three priming conditions were used: congruent, incongruent and neutral. The facilitating effects of priming were observed in the grasping decision task for drawings of objects and blocks but not object names. The visual information about congruent orientation in the prime quickened participants' responses but had no effect on response accuracy. The results are discussed in the context of the hypothesis that an object automatically potentiates grasping associated with it, and that the on-line visual information is necessary for grasping potentiation to occur. The possibility that the most frequent orientation of familiar objects might be included in object-action representation is also discussed.
Fast Grasp Contact Computation for a Serial Robot
NASA Technical Reports Server (NTRS)
Hargrave, Brian (Inventor); Shi, Jianying (Inventor); Diftler, Myron A. (Inventor)
2015-01-01
A system includes a controller and a serial robot having links that are interconnected by a joint, wherein the robot can grasp a three-dimensional (3D) object in response to a commanded grasp pose. The controller receives input information, including the commanded grasp pose, a first set of information describing the kinematics of the robot, and a second set of information describing the position of the object to be grasped. The controller also calculates, in a two-dimensional (2D) plane, a set of contact points between the serial robot and a surface of the 3D object needed for the serial robot to achieve the commanded grasp pose. A required joint angle is then calculated in the 2D plane between the pair of links using the set of contact points. A control action is then executed with respect to the motion of the serial robot using the required joint angle.
Magdalon, Eliane C; Michaelsen, Stella M; Quevedo, Antonio A; Levin, Mindy F
2011-09-01
Virtual reality (VR) technology is being used with increasing frequency as a training medium for motor rehabilitation. However, before addressing training effectiveness in virtual environments (VEs), it is necessary to identify if movements made in such environments are kinematically similar to those made in physical environments (PEs) and the effect of provision of haptic feedback on these movement patterns. These questions are important since reach-to-grasp movements may be inaccurate when visual or haptic feedback is altered or absent. Our goal was to compare kinematics of reaching and grasping movements to three objects performed in an immersive three-dimensional (3D) VE with haptic feedback (cyberglove/grasp system) viewed through a head-mounted display to those made in an equivalent physical environment (PE). We also compared movements in PE made with and without wearing the cyberglove/grasp haptic feedback system. Ten healthy subjects (8 women, 62.1±8.8years) reached and grasped objects requiring 3 different grasp types (can, diameter 65.6mm, cylindrical grasp; screwdriver, diameter 31.6mm, power grasp; pen, diameter 7.5mm, precision grasp) in PE and visually similar virtual objects in VE. Temporal and spatial arm and trunk kinematics were analyzed. Movements were slower and grip apertures were wider when wearing the glove in both the PE and the VE compared to movements made in the PE without the glove. When wearing the glove, subjects used similar reaching trajectories in both environments, preserved the coordination between reaching and grasping and scaled grip aperture to object size for the larger object (cylindrical grasp). However, in VE compared to PE, movements were slower and had longer deceleration times, elbow extension was greater when reaching to the smallest object and apertures were wider for the power and precision grip tasks. Overall, the differences in spatial and temporal kinematics of movements between environments were greater than those due only to wearing the cyberglove/grasp system. Differences in movement kinematics due to the viewing environment were likely due to a lack of prior experience with the virtual environment, an uncertainty of object location and the restricted field-of-view when wearing the head-mounted display. The results can be used to inform the design and disposition of objects within 3D VEs for the study of the control of prehension and for upper limb rehabilitation. Copyright © 2011 Elsevier B.V. All rights reserved.
Multiple parietal-frontal pathways mediate grasping in macaque monkeys
Gharbawie, Omar A.; Stepniewska, Iwona; Qi, Huixin; Kaas, Jon H.
2011-01-01
The nodes of a parietal-frontal pathway that mediates grasping in primates are in anterior intraparietal area (AIP) and ventral premotor cortex (PMv). Nevertheless, multiple somatosensory and motor representations of the hand, respectively in parietal and frontal cortex, suggest that additional pathways remain unrealized. We explored this possibility in macaque monkeys by injecting retrograde tracers into grasp zones identified in M1, PMv, and area 2 with long train electrical stimulation. The M1 grasp zone was densely connected with other frontal cortex motor regions. The remainder of the connections originated from somatosensory areas 3a and S2/PV, and from the medial bank and fundus of the intraparietal sulcus (IPS). The PMv grasp zone was also densely connected with frontal cortex motor regions, albeit to a lesser extent than the M1 grasp zone. The remainder of the connections originated from areas S2/PV and aspects of the inferior parietal lobe such as PF, PFG, AIP, and the tip of the IPS. The area 2 grasp zone was densely connected with the hand representations of somatosensory areas 3b, 1, and S2/PV. The remainder of the connections was with areas 3a and 5 and the medial bank and fundus of the IPS. Connections with frontal cortex were relatively weak and concentrated in caudal M1. Thus, the three grasp zones may be nodes of parallel parietal-frontal pathways. Differential points of origin and termination of each pathway suggest varying functional specializations. Direct and indirect connections between those parietal-frontal pathways likely coordinate their respective functions into an accurate grasp. PMID:21832196
Space Geodetic Technique Co-location in Space: Simulation Results for the GRASP Mission
NASA Astrophysics Data System (ADS)
Kuzmicz-Cieslak, M.; Pavlis, E. C.
2011-12-01
The Global Geodetic Observing System-GGOS, places very stringent requirements in the accuracy and stability of future realizations of the International Terrestrial Reference Frame (ITRF): an origin definition at 1 mm or better at epoch and a temporal stability on the order of 0.1 mm/y, with similar numbers for the scale (0.1 ppb) and orientation components. These goals were derived from the requirements of Earth science problems that are currently the international community's highest priority. None of the geodetic positioning techniques can achieve this goal alone. This is due in part to the non-observability of certain attributes from a single technique. Another limitation is imposed from the extent and uniformity of the tracking network and the schedule of observational availability and number of suitable targets. The final limitation derives from the difficulty to "tie" the reference points of each technique at the same site, to an accuracy that will support the GGOS goals. The future GGOS network will address decisively the ground segment and to certain extent the space segment requirements. The JPL-proposed multi-technique mission GRASP (Geodetic Reference Antenna in Space) attempts to resolve the accurate tie between techniques, using their co-location in space, onboard a well-designed spacecraft equipped with GNSS receivers, a SLR retroreflector array, a VLBI beacon and a DORIS system. Using the anticipated system performance for all four techniques at the time the GGOS network is completed (ca 2020), we generated a number of simulated data sets for the development of a TRF. Our simulation studies examine the degree to which GRASP can improve the inter-technique "tie" issue compared to the classical approach, and the likely modus operandi for such a mission. The success of the examined scenarios is judged by the quality of the origin and scale definition of the resulting TRF.
Defense Advanced Research Projects Agency Strategic Plan
2007-02-01
be able to feel objects that are being grasped so that the prosthesis is experienced as an arm instead of as a tool; and (iii) development of...instrument, but also the ability to sense an artificial limb’s position without looking at it, and to actually " feel " precisely what the artificial limb...is touching by relaying sensations through residual nerves. (This program is also leveraging developments in a core technology program, Human Assisted
1987-01-01
two nodes behave identically. In GRASP, these constraints are entirely invisible from the user’s point of view. GRASP (Recall that the Levi - Civita ...virtual rotation GRASP is the first program implementing a new methodWl( = Levi -Ciudta symbol op for dynamic analysis of structures, parts of which may...natural coordinatization of sis for this methodology, which incorporates body flexibility components. with the large discrete motions previously
Nogami, Hirofumi; Higurashi, Eiji; Sawada, Renshi
2018-01-01
The purpose of this paper is to show the feasibility of grasping force control by feeding back signals of the developed micro-laser Doppler velocimeter (μ-LDV) and by discriminating whether a grasped object is slipping or not. LDV is well known as a high response surface velocity sensor which can measure various surfaces—such as metal, paper, film, and so on—thus suggesting the potential application of LDV as a slip sensor for grasping various objects. However, the use of LDV as a slip sensor has not yet been reported because the size of LDVs is too large to be installed on a robotic fingertip. We have solved the size problem and enabled the performance of a feasibility test with a few-millimeter-scale LDV referred to as micro-LDV (μ-LDV) by modifying the design which was adopted from MEMS (microelectromechanical systems) fabrication process. In this paper, by applying our developed μ-LDV as a slip sensor, we have successfully demonstrated grasping force control with three target objects—aluminum block, wood block, and white acrylic block—considering that various objects made of these materials can be found in homes and factories, without grasping force feedback. We provide proofs that LDV is a new promising candidate slip sensor for grasping force control to execute target grasping. PMID:29360799
Tan, U
1994-03-01
Relations of grasp-reflex strengths to serum free-thyroid hormone levels were studied in human neonates. In right-dominant (RH) males and females without familial sinistrality (-FS), grasp-reflex strengths from right (R) and left (L) inversely correlated with serum triiodothyronine (T3). In RH, +FS males, grasp-reflex strengths from R and L hands directly correlated with T3 (no correlations in RH, +FS females). There was no significant correlation between grasp reflex and T3 in non-right-handed (NRH), -FS neonates. In NRH +FS neonates, there was a significant negative linear correlation between grasp reflex from left and T3 only in NRH, +FS males. The following correlations were found between grasp reflex and thyroxine (T4): direct relation in RH, +FS males and females; inverse relation in NRH, -FS females only for the right hand; inverse correlations in NRH, +FS females. The R-L grasp reflex directly correlated with T3 in RH, -FS males, and inversely correlated with T3 in RH, -FS females (no significant correlations in others). These results indicated that thyroid hormones may influence cerebral maturation and lateralization differentially according to genetically predetermined cerebral organization. The generalizations of the hormonal effects on, at least, cerebral functioning would be wrong, if the genetically predetermined main features of the brain are neglected.
Rupp, Rüdiger; Kreilinger, Alex; Rohm, Martin; Kaiser, Vera; Müller-Putz, Gernot R
2012-01-01
Over the last decade the improvement of a missing hand function by application of neuroprostheses in particular the implantable Freehand system has been successfully shown in high spinal cord injured individuals. The clinically proven advantages of the Freehand system is its ease of use, the reproducible generation of two distinct functional grasp patterns and an analog control scheme based on movements of the contralateral shoulder. However, after the Freehand system is not commercially available for more than ten years, alternative grasp neuroprosthesis with a comparable functionality are still missing. Therefore, the aim of this study was to develop a non-invasive neuroprosthesis and to show that a degree of functional restoration can be provided to end users comparable to implanted devices. By introduction of an easy to handle forearm electrode sleeve the reproducible generation of two grasp patterns has been achieved. Generated grasp forces of the palmar grasp are in the range of the implanted system. Though pinch force of the lateral grasp is significantly lower, it can effectively used by a tetraplegic subject to perform functional tasks. The non-invasive grasp neuroprosthesis developed in this work may serve as an easy to apply and inexpensive way to restore a missing hand and finger function at any time after spinal cord injury.
Attention and reach-to-grasp movements in Parkinson's disease.
Lu, Cathy; Bharmal, Aamir; Kiss, Zelma H; Suchowersky, Oksana; Haffenden, Angela M
2010-08-01
The role of attention in grasping movements directed at common objects has not been examined in Parkinson's disease (PD), though these movements are critical to activities of daily living. Our primary objective was to determine whether patients with PD demonstrate automaticity in grasping movements directed toward common objects. Automaticity is assumed when tasks can be performed with little or no interference from concurrent tasks. Grasping performance in three patient groups (newly diagnosed, moderate, and advanced/surgically treated PD) on and off of their medication or deep brain stimulation was compared to performance in an age-matched control group. Automaticity was demonstrated by the absence of a decrement in grasping performance when attention was consumed by a concurrent spatial-visualization task. Only the control group and newly diagnosed PD group demonstrated automaticity in their grasping movements. The moderate and advanced PD groups did not demonstrate automaticity. Furthermore, the well-known effects of pharmacotherapy and surgical intervention on movement speed and muscle activation patterns did not appear to reduce the impact of attention-demanding tasks on grasping movements in those with moderate to advanced PD. By the moderate stage of PD, grasping is an attention-demanding process; this change is not ameliorated by dopaminergic or surgical treatments. These findings have important implications for activities of daily living, as devoting attention to the simplest of daily tasks would interfere with complex activities and potentially exacerbate fatigue.
Kopiske, Karl K; Bruno, Nicola; Hesse, Constanze; Schenk, Thomas; Franz, Volker H
2016-06-01
It has often been suggested that visual illusions affect perception but not actions such as grasping, as predicted by the "two-visual-systems" hypothesis of Milner and Goodale (1995, The Visual Brain in Action, Oxford University press). However, at least for the Ebbinghaus illusion, relevant studies seem to reveal a consistent illusion effect on grasping (Franz & Gegenfurtner, 2008. Grasping visual illusions: consistent data and no dissociation. Cognitive Neuropsychology). Two interpretations are possible: either grasping is not immune to illusions (arguing against dissociable processing mechanisms for vision-for-perception and vision-for-action), or some other factors modulate grasping in ways that mimic a vision-for perception effect in actions. It has been suggested that one such factor may be obstacle avoidance (Haffenden Schiff & Goodale, 2001. The dissociation between perception and action in the Ebbinghaus illusion: nonillusory effects of pictorial cues on grasp. Current Biology, 11, 177-181). In four different labs (total N = 144), we conducted an exact replication of previous studies suggesting obstacle avoidance mechanisms, implementing conditions that tested grasping as well as multiple perceptual tasks. This replication was supplemented by additional conditions to obtain more conclusive results. Our results confirm that grasping is affected by the Ebbinghaus illusion and demonstrate that this effect cannot be explained by obstacle avoidance. Copyright © 2016 Elsevier Ltd. All rights reserved.
Similar Cerebral Motor Plans for Real and Virtual Actions
Bozzacchi, Chiara; Giusti, Maria Assunta; Pitzalis, Sabrina; Spinelli, Donatella; Di Russo, Francesco
2012-01-01
A simple movement, such as pressing a button, can acquire different meanings by producing different consequences, such as starting an elevator or switching a TV channel. We evaluated whether the brain activity preceding a simple action is modulated by the expected consequences of the action itself. To further this aim, the motor-related cortical potentials were compared during two key-press actions that were identical from the kinematics point of view but different in both meaning and consequences. In one case (virtual grasp), the key-press started a video clip showing a hand moving toward a cup and grasping it; in the other case, the key-press did not produce any consequence (key-press). A third condition (real grasp) was also compared, in which subjects actually grasped the cup, producing the same action presented in the video clip. Data were collected from fifteen subjects. The results showed that motor preparation for virtual grasp (starting 3 s before the movement onset) was different from that of the key-press and similar to the real grasp preparation–as if subjects had to grasp the cup in person. In particular, both virtual and real grasp presented a posterior parietal negativity preceding activity in motor and pre-motor areas. In summary, this finding supports the hypothesis that motor preparation is affected by the meaning of the action, even when the action is only virtual. PMID:23112847
Flat Plate Solar Array Project: Proceedings of the 20th Project Integration Meeting
NASA Technical Reports Server (NTRS)
Mcdonald, R. R.
1982-01-01
Progress made by the Flat-Plate Solar Array Project during the period November 1981 to April 1982 is reported. Project analysis and integration, technology research in silicon material, large-area silicon sheet and environmental isolation, cell and module formation, engineering sciences, and module performance and failure analysis are covered.
Whitwell, Robert L.; Ganel, Tzvi; Byrne, Caitlin M.; Goodale, Melvyn A.
2015-01-01
Investigators study the kinematics of grasping movements (prehension) under a variety of conditions to probe visuomotor function in normal and brain-damaged individuals. “Natural” prehensile acts are directed at the goal object and are executed using real-time vision. Typically, they also entail the use of tactile, proprioceptive, and kinesthetic sources of haptic feedback about the object (“haptics-based object information”) once contact with the object has been made. Natural and simulated (pantomimed) forms of prehension are thought to recruit different cortical structures: patient DF, who has visual form agnosia following bilateral damage to her temporal-occipital cortex, loses her ability to scale her grasp aperture to the size of targets (“grip scaling”) when her prehensile movements are based on a memory of a target previewed 2 s before the cue to respond or when her grasps are directed towards a visible virtual target but she is denied haptics-based information about the target. In the first of two experiments, we show that when DF performs real-time pantomimed grasps towards a 7.5 cm displaced imagined copy of a visible object such that her fingers make contact with the surface of the table, her grip scaling is in fact quite normal. This finding suggests that real-time vision and terminal tactile feedback are sufficient to preserve DF’s grip scaling slopes. In the second experiment, we examined an “unnatural” grasping task variant in which a tangible target (along with any proxy such as the surface of the table) is denied (i.e., no terminal tactile feedback). To do this, we used a mirror-apparatus to present virtual targets with and without a spatially coincident copy for the participants to grasp. We compared the grasp kinematics from trials with and without terminal tactile feedback to a real-time-pantomimed grasping task (one without tactile feedback) in which participants visualized a copy of the visible target as instructed in our laboratory in the past. Compared to natural grasps, removing tactile feedback increased RT, slowed the velocity of the reach, reduced in-flight grip aperture, increased the slopes relating grip aperture to target width, and reduced the final grip aperture (FGA). All of these effects were also observed in the real time-pantomime grasping task. These effects seem to be independent of those that arise from using the mirror in general as we also compared grasps directed towards virtual targets to those directed at real ones viewed directly through a pane of glass. These comparisons showed that the grasps directed at virtual targets increased grip aperture, slowed the velocity of the reach, and reduced the slopes relating grip aperture to the widths of the target. Thus, using the mirror has real consequences on grasp kinematics, reflecting the importance of task-relevant sources of online visual information for the programming and updating of natural prehensile movements. Taken together, these results provide compelling support for the view that removing terminal tactile feedback, even when the grasps are target-directed, induces a switch from real-time visual control towards one that depends more on visual perception and cognitive supervision. Providing terminal tactile feedback and real-time visual information can evidently keep the dorsal visuomotor system operating normally for prehensile acts. PMID:25999834
Whitwell, Robert L; Ganel, Tzvi; Byrne, Caitlin M; Goodale, Melvyn A
2015-01-01
Investigators study the kinematics of grasping movements (prehension) under a variety of conditions to probe visuomotor function in normal and brain-damaged individuals. "Natural" prehensile acts are directed at the goal object and are executed using real-time vision. Typically, they also entail the use of tactile, proprioceptive, and kinesthetic sources of haptic feedback about the object ("haptics-based object information") once contact with the object has been made. Natural and simulated (pantomimed) forms of prehension are thought to recruit different cortical structures: patient DF, who has visual form agnosia following bilateral damage to her temporal-occipital cortex, loses her ability to scale her grasp aperture to the size of targets ("grip scaling") when her prehensile movements are based on a memory of a target previewed 2 s before the cue to respond or when her grasps are directed towards a visible virtual target but she is denied haptics-based information about the target. In the first of two experiments, we show that when DF performs real-time pantomimed grasps towards a 7.5 cm displaced imagined copy of a visible object such that her fingers make contact with the surface of the table, her grip scaling is in fact quite normal. This finding suggests that real-time vision and terminal tactile feedback are sufficient to preserve DF's grip scaling slopes. In the second experiment, we examined an "unnatural" grasping task variant in which a tangible target (along with any proxy such as the surface of the table) is denied (i.e., no terminal tactile feedback). To do this, we used a mirror-apparatus to present virtual targets with and without a spatially coincident copy for the participants to grasp. We compared the grasp kinematics from trials with and without terminal tactile feedback to a real-time-pantomimed grasping task (one without tactile feedback) in which participants visualized a copy of the visible target as instructed in our laboratory in the past. Compared to natural grasps, removing tactile feedback increased RT, slowed the velocity of the reach, reduced in-flight grip aperture, increased the slopes relating grip aperture to target width, and reduced the final grip aperture (FGA). All of these effects were also observed in the real time-pantomime grasping task. These effects seem to be independent of those that arise from using the mirror in general as we also compared grasps directed towards virtual targets to those directed at real ones viewed directly through a pane of glass. These comparisons showed that the grasps directed at virtual targets increased grip aperture, slowed the velocity of the reach, and reduced the slopes relating grip aperture to the widths of the target. Thus, using the mirror has real consequences on grasp kinematics, reflecting the importance of task-relevant sources of online visual information for the programming and updating of natural prehensile movements. Taken together, these results provide compelling support for the view that removing terminal tactile feedback, even when the grasps are target-directed, induces a switch from real-time visual control towards one that depends more on visual perception and cognitive supervision. Providing terminal tactile feedback and real-time visual information can evidently keep the dorsal visuomotor system operating normally for prehensile acts.
Emergent coordination underlying learning to reach to grasp with a brain-machine interface.
Vaidya, Mukta; Balasubramanian, Karthikeyan; Southerland, Joshua; Badreldin, Islam; Eleryan, Ahmed; Shattuck, Kelsey; Gururangan, Suchin; Slutzky, Marc; Osborne, Leslie; Fagg, Andrew; Oweiss, Karim; Hatsopoulos, Nicholas G
2018-04-01
The development of coordinated reach-to-grasp movement has been well studied in infants and children. However, the role of motor cortex during this development is unclear because it is difficult to study in humans. We took the approach of using a brain-machine interface (BMI) paradigm in rhesus macaques with prior therapeutic amputations to examine the emergence of novel, coordinated reach to grasp. Previous research has shown that after amputation, the cortical area previously involved in the control of the lost limb undergoes reorganization, but prior BMI work has largely relied on finding neurons that already encode specific movement-related information. In this study, we taught macaques to cortically control a robotic arm and hand through operant conditioning, using neurons that were not explicitly reach or grasp related. Over the course of training, stereotypical patterns emerged and stabilized in the cross-covariance between the reaching and grasping velocity profiles, between pairs of neurons involved in controlling reach and grasp, and to a comparable, but lesser, extent between other stable neurons in the network. In fact, we found evidence of this structured coordination between pairs composed of all combinations of neurons decoding reach or grasp and other stable neurons in the network. The degree of and participation in coordination was highly correlated across all pair types. Our approach provides a unique model for studying the development of novel, coordinated reach-to-grasp movement at the behavioral and cortical levels. NEW & NOTEWORTHY Given that motor cortex undergoes reorganization after amputation, our work focuses on training nonhuman primates with chronic amputations to use neurons that are not reach or grasp related to control a robotic arm to reach to grasp through the use of operant conditioning, mimicking early development. We studied the development of a novel, coordinated behavior at the behavioral and cortical level, and the neural plasticity in M1 associated with learning to use a brain-machine interface.
Design and fabrication of robotic gripper for grasping in minimizing contact force
NASA Astrophysics Data System (ADS)
Heidari, Hamidreza; Pouria, Milad Jafary; Sharifi, Shahriar; Karami, Mahmoudreza
2018-03-01
This paper presents a new method to improve the kinematics of robot gripper for grasping in unstructured environments, such as space operations. The robot gripper is inspired from the human hand and kept the hand design close to the structure of human fingers to provide successful grasping capabilities. The main goal is to improve kinematic structure of gripper to increase the grasping capability of large objects, decrease the contact forces and makes a successful grasp of various objects in unstructured environments. This research will describe the development of a self-adaptive and reconfigurable robotic hand for space operations through mechanical compliance which is versatile, robust and easy to control. Our model contains two fingers, two-link and three-link, with combining a kinematic model of thumb index. Moreover, some experimental tests are performed to examine the effectiveness of the hand-made in real, unstructured tasks. The results represent that the successful grasp range is improved about 30% and the contact forces is reduced approximately 10% for a wide range of target object size. According to the obtained results, the proposed approach provides an accommodative kinematic model which makes the better grasping capability by fingers geometries for a robot gripper.
Development and assessment of a hand assist device: GRIPIT.
Kim, Byungchul; In, Hyunki; Lee, Dae-Young; Cho, Kyu-Jin
2017-02-21
Although various hand assist devices have been commercialized for people with paralysis, they are somewhat limited in terms of tool fixation and device attachment method. Hand exoskeleton robots allow users to grasp a wider range of tools but are heavy, complicated, and bulky owing to the presence of numerous actuators and controllers. The GRIPIT hand assist device overcomes the limitations of both conventional devices and exoskeleton robots by providing improved tool fixation and device attachment in a lightweight and compact device. GRIPIT has been designed to assist tripod grasp for people with spinal cord injury because this grasp posture is frequently used in school and offices for such activities as writing and grasping small objects. The main development objective of GRIPIT is to assist users to grasp tools with their own hand using a lightweight, compact assistive device that is manually operated via a single wire. GRIPIT consists of only a glove, a wire, and a small structure that maintains tendon tension to permit a stable grasp. The tendon routing points are designed to apply force to the thumb, index finger, and middle finger to form a tripod grasp. A tension-maintenance structure sustains the grasp posture with appropriate tension. Following device development, four people with spinal cord injury were recruited to verify the writing performance of GRIPIT compared to the performance of a conventional penholder and handwriting. Writing was chosen as the assessment task because it requires a tripod grasp, which is one of the main performance objectives of GRIPIT. New assessment, which includes six different writing tasks, was devised to measure writing ability from various viewpoints including both qualitative and quantitative methods, while most conventional assessments include only qualitative methods or simple time measuring assessments. Appearance, portability, difficulty of wearing, difficulty of grasping the subject, writing sensation, fatigability, and legibility were measured to assess qualitative performance while writing various words and sentences. Results showed that GRIPIT is relatively complicated to wear and use compared to a conventional assist device but has advantages for writing sensation, fatigability, and legibility because it affords sufficient grasp force during writing. Two quantitative performance factors were assessed, accuracy of writing and solidity of writing. To assess accuracy of writing, we asked subjects to draw various figures under given conditions. To assess solidity of writing, pen tip force and the angle variation of the pen were measured. Quantitative evaluation results showed that GRIPIT helps users to write accurately without pen shakes even high force is applied on the pen. Qualitative and quantitative results were better when subjects used GRIPIT than when they used the conventional penholder, mainly because GRIPIT allowed them to exert a higher grasp force. Grasp force is important because disabled people cannot control their fingers and thus need to move their entire arm to write, while non-disabled people only need to move their fingers to write. The tension-maintenance structure developed for GRIPIT provides appropriate grasp force and moment balance on the user's hand, but the other writing method only fixes the pen using friction force or requires the user's arm to generate a grasp force.
Grasp planning under uncertainty
NASA Technical Reports Server (NTRS)
Erkmen, A. M.; Stephanou, H. E.
1989-01-01
The planning of dexterous grasps for multifingered robot hands operating in uncertain environments is covered. A sensor-based approach to the planning of a reach path prior to grasping is first described. An on-line, joint space finger path planning algorithm for the enclose phase of grasping was then developed. The algorithm minimizes the impact momentum of the hand. It uses a Preshape Jacobian matrix to map task-level hand preshape requirements into kinematic constraints. A master slave scheme avoids inter-finger collisions and reduces the dimensionality of the planning problem.
Clearing a Pile of Unknown Objects using Interactive Perception
2012-11-01
blocks and the shampoo . The robot now decides to grasp the bottle of shampoo . Next, the tissue box and the chunk of wood are pushed and grasped. The...20 seconds. Poking an object requires 12 (a) Initial pile (b) Poking macaroni box (c) After poking (d) Grasping shampoo (e) After grasping (f) Pooking...objects: a tissue box, a chunk of wood, a bottle of shampoo , a box of macaroni, and toy blocks. The algorithm switches between pushing to verify
The influence of object shape and center of mass on grasp and gaze
Desanghere, Loni; Marotta, Jonathan J.
2015-01-01
Recent experiments examining where participants look when grasping an object found that fixations favor the eventual index finger landing position on the object. Even though the act of picking up an object must involve complex high-level computations such as the visual analysis of object contours, surface properties, knowledge of an object’s function and center of mass (COM) location, these investigations have generally used simple symmetrical objects – where COM and horizontal midline overlap. Less research has been aimed at looking at how variations in object properties, such as differences in curvature and changes in COM location, affect visual and motor control. The purpose of this study was to examine grasp and fixation locations when grasping objects whose COM was positioned to the left or right of the objects horizontal midline (Experiment 1) and objects whose COM was moved progressively further from the midline of the objects based on the alteration of the object’s shape (Experiment 2). Results from Experiment 1 showed that object COM position influenced fixation locations and grasp locations differently, with fixations not as tightly linked to index finger grasp locations as was previously reported with symmetrical objects. Fixation positions were also found to be more central on the non-symmetrical objects. This difference in gaze position may provide a more holistic view, which would allow both index finger and thumb positions to be monitored while grasping. Finally, manipulations of COM distance (Experiment 2) exerted marked effects on the visual analysis of the objects when compared to its influence on grasp locations, with fixation locations more sensitive to these manipulations. Together, these findings demonstrate how object features differentially influence gaze vs. grasp positions during object interaction. PMID:26528207
van Kan, Peter L E; McCurdy, Martha L
2002-01-01
Reaching to grasp is of fundamental importance to primate motor behavior. One descending motor pathway that contributes to the control of this behavior is the rubrospinal tract. An important source of origin of the rubrospinal tract is the magnocellular red nucleus (RNm). Forelimb RNm neurons discharge vigorously during reach-to-grasp movements. RNm discharge is important for hand use, as coordinated whole-limb movements without hand use are not associated with strong discharge. Because RNm is functionally linked to muscles of the entire forelimb, RNm discharge may also contribute to use of the proximal limb that accompanies hand use. If RNm contributes to proximal limb use, we predict discharge to differ for reaches that differ in proximal limb involvement but require the same grasp. We tested this prediction by measuring discharge of individual RNm neurons while monkeys reached to grasp objects in four spatial locations in front of them. The animals reached from the waist to locations to the left, right, above, and below the shoulder of the "reaching" limb. RNm neurons of our sample were activated strongly during reach-to-grasp, and discharge of a third of the neurons tested depended on the spatial location of the object grasped. Discharge of RNm neurons and EMG activity of many of the distal and proximal forelimb muscles we tested were larger for reaching to grasp in the upper and/or right than lower and left target locations. Based on comparisons of each individual neuron's discharge patterns during reaches with and without preshaping the hand, we conclude that target location-dependent modulations in discharge rate of the majority of RNm neurons whose discharge differed for reaching to grasp in the four target locations contributed to aspects of hand preshaping that covaried with reach direction.
Decoding natural reach-and-grasp actions from human EEG
NASA Astrophysics Data System (ADS)
Schwarz, Andreas; Ofner, Patrick; Pereira, Joana; Ioana Sburlea, Andreea; Müller-Putz, Gernot R.
2018-02-01
Objective. Despite the high number of degrees of freedom of the human hand, most actions of daily life can be executed incorporating only palmar, pincer and lateral grasp. In this study we attempt to discriminate these three different executed reach-and-grasp actions utilizing their EEG neural correlates. Approach. In a cue-guided experiment, 15 healthy individuals were asked to perform these actions using daily life objects. We recorded 72 trials for each reach-and-grasp condition and from a no-movement condition. Main results. Using low-frequency time domain features from 0.3 to 3 Hz, we achieved binary classification accuracies of 72.4%, STD ± 5.8% between grasp types, for grasps versus no-movement condition peak performances of 93.5%, STD ± 4.6% could be reached. In an offline multiclass classification scenario which incorporated not only all reach-and-grasp actions but also the no-movement condition, the highest performance could be reached using a window of 1000 ms for feature extraction. Classification performance peaked at 65.9%, STD ± 8.1%. Underlying neural correlates of the reach-and-grasp actions, investigated over the primary motor cortex, showed significant differences starting from approximately 800 ms to 1200 ms after the movement onset which is also the same time frame where classification performance reached its maximum. Significance. We could show that it is possible to discriminate three executed reach-and-grasp actions prominent in people’s everyday use from non-invasive EEG. Underlying neural correlates showed significant differences between all tested conditions. These findings will eventually contribute to our attempt of controlling a neuroprosthesis in a natural and intuitive way, which could ultimately benefit motor impaired end users in their daily life actions.
Mapping chromatic pathways in the Drosophila visual system.
Lin, Tzu-Yang; Luo, Jiangnan; Shinomiya, Kazunori; Ting, Chun-Yuan; Lu, Zhiyuan; Meinertzhagen, Ian A; Lee, Chi-Hon
2016-02-01
In Drosophila, color vision and wavelength-selective behaviors are mediated by the compound eye's narrow-spectrum photoreceptors R7 and R8 and their downstream medulla projection (Tm) neurons Tm5a, Tm5b, Tm5c, and Tm20 in the second optic neuropil or medulla. These chromatic Tm neurons project axons to a deeper optic neuropil, the lobula, which in insects has been implicated in processing and relaying color information to the central brain. The synaptic targets of the chromatic Tm neurons in the lobula are not known, however. Using a modified GFP reconstitution across synaptic partners (GRASP) method to probe connections between the chromatic Tm neurons and 28 known and novel types of lobula neurons, we identify anatomically the visual projection neurons LT11 and LC14 and the lobula intrinsic neurons Li3 and Li4 as synaptic targets of the chromatic Tm neurons. Single-cell GRASP analyses reveal that Li4 receives synaptic contacts from over 90% of all four types of chromatic Tm neurons, whereas LT11 is postsynaptic to the chromatic Tm neurons, with only modest selectivity and at a lower frequency and density. To visualize synaptic contacts at the ultrastructural level, we develop and apply a "two-tag" double-labeling method to label LT11's dendrites and the mitochondria in Tm5c's presynaptic terminals. Serial electron microscopic reconstruction confirms that LT11 receives direct contacts from Tm5c. This method would be generally applicable to map the connections of large complex neurons in Drosophila and other animals. © 2015 Wiley Periodicals, Inc.
When pliers become fingers in the monkey motor system
Umiltà, M. A.; Escola, L.; Intskirveli, I.; Grammont, F.; Rochat, M.; Caruana, F.; Jezzini, A.; Gallese, V.; Rizzolatti, G.
2008-01-01
The capacity to use tools is a fundamental evolutionary achievement. Its essence stands in the capacity to transfer a proximal goal (grasp a tool) to a distal goal (e.g., grasp food). Where and how does this goal transfer occur? Here, we show that, in monkeys trained to use tools, cortical motor neurons, active during hand grasping, also become active during grasping with pliers, as if the pliers were now the hand fingers. This motor embodiment occurs both for normal pliers and for “reverse pliers,” an implement that requires finger opening, instead of their closing, to grasp an object. We conclude that the capacity to use tools is based on an inherently goal-centered functional organization of primate cortical motor areas. PMID:18238904
The contributions of vision and haptics to reaching and grasping
Stone, Kayla D.; Gonzalez, Claudia L. R.
2015-01-01
This review aims to provide a comprehensive outlook on the sensory (visual and haptic) contributions to reaching and grasping. The focus is on studies in developing children, normal, and neuropsychological populations, and in sensory-deprived individuals. Studies have suggested a right-hand/left-hemisphere specialization for visually guided grasping and a left-hand/right-hemisphere specialization for haptically guided object recognition. This poses the interesting possibility that when vision is not available and grasping relies heavily on the haptic system, there is an advantage to use the left hand. We review the evidence for this possibility and dissect the unique contributions of the visual and haptic systems to grasping. We ultimately discuss how the integration of these two sensory modalities shape hand preference. PMID:26441777
Kleinholdermann, Urs; Franz, Volker H; Gegenfurtner, Karl R; Stockmeier, Kerstin
2009-07-01
We used a virtual reality setup to let participants grasp discs, which differed in luminance, chromaticity and size. Current theories on perception and action propose a division of labor in the brain into a color proficient perception pathway and a less color-capable action pathway. In this study, we addressed the question whether isoluminant stimuli, which provide only a chromatic but no luminance contrast for action planning, are harder to grasp than stimuli providing luminance contrast or both kinds of contrast. Although we found that grasps of isoluminant stimuli had a slightly steeper slope relating the maximum grip aperture to disc size, all other measures of grip quality were unaffected. Overall, our results do not support the view that isoluminance of stimulus and background impedes the planning of a grasping movement.
Lanzilotto, Marco; Livi, Alessandro; Maranesi, Monica; Gerbella, Marzio; Barz, Falk; Ruther, Patrick; Fogassi, Leonardo; Rizzolatti, Giacomo; Bonini, Luca
2016-01-01
Grasping relies on a network of parieto-frontal areas lying on the dorsolateral and dorsomedial parts of the hemispheres. However, the initiation and sequencing of voluntary actions also requires the contribution of mesial premotor regions, particularly the pre-supplementary motor area F6. We recorded 233 F6 neurons from 2 monkeys with chronic linear multishank neural probes during reaching–grasping visuomotor tasks. We showed that F6 neurons play a role in the control of forelimb movements and some of them (26%) exhibit visual and/or motor specificity for the target object. Interestingly, area F6 neurons form 2 functionally distinct populations, showing either visually-triggered or movement-related bursts of activity, in contrast to the sustained visual-to-motor activity displayed by ventral premotor area F5 neurons recorded in the same animals and with the same task during previous studies. These findings suggest that F6 plays a role in object grasping and extend existing models of the cortical grasping network. PMID:27733538
Dynamical characteristics of surface EMG signals of hand grasps via recurrence plot.
Ouyang, Gaoxiang; Zhu, Xiangyang; Ju, Zhaojie; Liu, Honghai
2014-01-01
Recognizing human hand grasp movements through surface electromyogram (sEMG) is a challenging task. In this paper, we investigated nonlinear measures based on recurrence plot, as a tool to evaluate the hidden dynamical characteristics of sEMG during four different hand movements. A series of experimental tests in this study show that the dynamical characteristics of sEMG data with recurrence quantification analysis (RQA) can distinguish different hand grasp movements. Meanwhile, adaptive neuro-fuzzy inference system (ANFIS) is applied to evaluate the performance of the aforementioned measures to identify the grasp movements. The experimental results show that the recognition rate (99.1%) based on the combination of linear and nonlinear measures is much higher than those with only linear measures (93.4%) or nonlinear measures (88.1%). These results suggest that the RQA measures might be a potential tool to reveal the sEMG hidden characteristics of hand grasp movements and an effective supplement for the traditional linear grasp recognition methods.
Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis.
Schaefer, Sydney Y; DeJong, Stacey L; Cherry, Kendra M; Lang, Catherine E
2012-04-01
This study investigated whether grip type and/or task goal influenced reaching and grasping performance in poststroke hemiparesis. Sixteen adults with poststroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared with the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment.
A simple rule of thumb for elegant prehension.
Mon-Williams, M; Tresilian, J R
2001-07-10
Reaching out to grasp an object (prehension) is a deceptively elegant and skilled behavior. The movement prior to object contact can be described as having two components, the movement of the hand to an appropriate location for gripping the object, the "transport" component, and the opening and closing of the aperture between the fingers as they prepare to grip the target, the "grasp" component. The grasp component is sensitive to the size of the object, so that a larger grasp aperture is formed for wider objects; the maximum grasp aperture (MGA) is a little wider than the width of the target object and occurs later in the movement for larger objects. We present a simple model that can account for the temporal relationship between the transport and grasp components. We report the results of an experiment providing empirical support for our "rule of thumb." The model provides a simple, but plausible, account of a neural control strategy that has been the center of debate over the last two decades.
Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis
Schaefer, Sydney Y.; DeJong, Stacey L.; Cherry, Kendra M.; Lang, Catherine E.
2011-01-01
This study investigated whether grip type and/or task goal influenced reaching and grasping performance in post-stroke hemiparesis. Sixteen adults with post-stroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared to the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment. PMID:22357103
Tang, Rixin; Whitwell, Robert L; Goodale, Melvyn A
2014-01-01
Previous research (Whitwell et al. in Exp Brain Res 188:603-611, 2008; Whitwell and Goodale in Exp Brain Res 194:619-629, 2009) has shown that trial history, but not anticipatory knowledge about the presence or absence of visual feedback on an upcoming trial, plays a vital role in determining how that feedback is exploited when grasping with the right hand. Nothing is known about how the non-dominant left hand behaves under the same feedback regimens. In present study, therefore, we compared peak grip aperture (PGA) for left- and right-hand grasps executed with and without visual feedback (i.e., closed- vs. open-loop conditions) in right-handed individuals under three different trial schedules: the feedback conditions were blocked separately, they were randomly interleaved, or they were alternated. When feedback conditions were blocked, the PGA was much larger for open-loop trials as compared to closed-loop trials, although this difference was more pronounced for right-hand grasps than left-hand grasps. Like Whitwell et al., we found that mixing open- and closed-loop trials together, compared to blocking them separately, homogenized the PGA for open- and closed-loop grasping in the right hand (i.e., the PGAs became smaller on open-loop trials and larger on closed-loop trials). In addition, the PGAs for right-hand grasps were entirely determined by trial history and not by knowledge of whether or not visual feedback would be available on an upcoming trial. In contrast to grasps made with the right hand, grasps made by the left hand were affected both by trial history and by anticipatory knowledge of the upcoming visual feedback condition. But these effects were observed only on closed-loop trials, i.e., the PGAs of grasps made with the left hand on closed-loop trials were smaller when participants could anticipate the availability of feedback on an upcoming trial (alternating trials) than when they could not (randomized trials). In contrast, grasps made with the left hand on open-loop trials exhibited the same large PGAs under all feedback schedules: blocked, random, or alternating. In other words, there was no evidence for homogenization. Taken together, these results suggest that in addition to the real-time demands of the task, such as the target's size and position and the availability of visual feedback, the initial (i.e., pre-movement) programming of right-hand grasping relies on what happened on the previous trial, whereas the programming of left-hand grasping is more cognitively supervised and exploits explicit information about trial order to prepare for an upcoming trial.
Biclustering of gene expression data using reactive greedy randomized adaptive search procedure.
Dharan, Smitha; Nair, Achuthsankar S
2009-01-30
Biclustering algorithms belong to a distinct class of clustering algorithms that perform simultaneous clustering of both rows and columns of the gene expression matrix and can be a very useful analysis tool when some genes have multiple functions and experimental conditions are diverse. Cheng and Church have introduced a measure called mean squared residue score to evaluate the quality of a bicluster and has become one of the most popular measures to search for biclusters. In this paper, we review basic concepts of the metaheuristics Greedy Randomized Adaptive Search Procedure (GRASP)-construction and local search phases and propose a new method which is a variant of GRASP called Reactive Greedy Randomized Adaptive Search Procedure (Reactive GRASP) to detect significant biclusters from large microarray datasets. The method has two major steps. First, high quality bicluster seeds are generated by means of k-means clustering. In the second step, these seeds are grown using the Reactive GRASP, in which the basic parameter that defines the restrictiveness of the candidate list is self-adjusted, depending on the quality of the solutions found previously. We performed statistical and biological validations of the biclusters obtained and evaluated the method against the results of basic GRASP and as well as with the classic work of Cheng and Church. The experimental results indicate that the Reactive GRASP approach outperforms the basic GRASP algorithm and Cheng and Church approach. The Reactive GRASP approach for the detection of significant biclusters is robust and does not require calibration efforts.
Li, Zhi; Milutinović, Dejan; Rosen, Jacob
2017-05-01
Reach-to-grasp arm postures differ from those in pure reaching because they are affected by grasp position/orientation, rather than simple transport to a position during a reaching motion. This paper investigates this difference via an analysis of experimental data collected on reaching and reach-to-grasp motions. A seven-degree-of-freedom (DOFs) kinematic arm model with the swivel angle is used for the motion analysis. Compared to a widely used anatomical arm model, this model distinguishes clearly the four grasping-relevant DOFs (GR-DOFs) that are affected by positions and orientations of the objects to be grasped. These four GR-DOFs include the swivel angle that measures the elbow rotation about the shoulder-wrist axis, and three wrist joint angles. For each GR-DOF, we quantify position vs orientation task-relevance bias that measures how much the DOF is affected by the grasping position vs orientation. The swivel angle and forearm supination have similar bias, and the analysis of their motion suggests two hypotheses regarding the synergistic coordination of the macro- and micro-structures of the human arm (1) DOFs with similar task-relevance are synergistically coordinated; and (2) such synergy breaks when a task-relevant DOF is close to its joint limit without necessarily reaching the limit. This study provides a motion analysis method to reduce the control complexity for reach-to-grasp tasks, and suggests using dynamic coupling to coordinate the hand and arm of upper-limb exoskeletons.
General Rotorcraft Aeromechanical Stability Program (GRASP): Theory manual
NASA Technical Reports Server (NTRS)
Hodges, Dewey H.; Hopkins, A. Stewart; Kunz, Donald L.; Hinnant, Howard E.
1990-01-01
The general rotorcraft aeromechanical stability program (GRASP) was developed to calculate aeroelastic stability for rotorcraft in hovering flight, vertical flight, and ground contact conditions. GRASP is described in terms of its capabilities and its philosophy of modeling. The equations of motion that govern the physical system are described, as well as the analytical approximations used to derive them. The equations include the kinematical equation, the element equations, and the constraint equations. In addition, the solution procedures used by GRASP are described. GRASP is capable of treating the nonlinear static and linearized dynamic behavior of structures represented by arbitrary collections of rigid-body and beam elements. These elements may be connected in an arbitrary fashion, and are permitted to have large relative motions. The main limitation of this analysis is that periodic coefficient effects are not treated, restricting rotorcraft flight conditions to hover, axial flight, and ground contact. Instead of following the methods employed in other rotorcraft programs. GRASP is designed to be a hybrid of the finite-element method and the multibody methods used in spacecraft analysis. GRASP differs from traditional finite-element programs by allowing multiple levels of substructure in which the substructures can move and/or rotate relative to others with no small-angle approximations. This capability facilitates the modeling of rotorcraft structures, including the rotating/nonrotating interface and the details of the blade/root kinematics for various types. GRASP differs from traditional multibody programs by considering aeroelastic effects, including inflow dynamics (simple unsteady aerodynamics) and nonlinear aerodynamic coefficients.
Development of an Advanced Hydraulic Fracture Mapping System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norm Warpinski; Steve Wolhart; Larry Griffin
The project to develop an advanced hydraulic fracture mapping system consisted of both hardware and analysis components in an effort to build, field, and analyze combined data from tiltmeter and microseismic arrays. The hardware sections of the project included: (1) the building of new tiltmeter housings with feedthroughs for use in conjunction with a microseismic array, (2) the development of a means to use separate telemetry systems for the tilt and microseismic arrays, and (3) the selection and fabrication of an accelerometer sensor system to improve signal-to-noise ratios. The analysis sections of the project included a joint inversion for analysismore » and interpretation of combined tiltmeter and microseismic data and improved methods for extracting slippage planes and other reservoir information from the microseisms. In addition, testing was performed at various steps in the process to assess the data quality and problems/issues that arose during various parts of the project. A prototype array was successfully tested and a full array is now being fabricated for industrial use.« less
Grasping objects autonomously in simulated KC-135 zero-g
NASA Technical Reports Server (NTRS)
Norsworthy, Robert S.
1994-01-01
The KC-135 aircraft was chosen for simulated zero gravity testing of the Extravehicular Activity Helper/retriever (EVAHR). A software simulation of the EVAHR hardware, KC-135 flight dynamics, collision detection and grasp inpact dynamics has been developed to integrate and test the EVAHR software prior to flight testing on the KC-135. The EVAHR software will perform target pose estimation, tracking, and motion estimation for rigid, freely rotating, polyhedral objects. Manipulator grasp planning and trajectory control software has also been developed to grasp targets while avoiding collisions.
Visual guidance in control of grasping.
Janssen, Peter; Scherberger, Hansjörg
2015-07-08
Humans and other primates possess a unique capacity to grasp and manipulate objects skillfully, a facility pervasive in everyday life that has undoubtedly contributed to the success of our species. When we reach and grasp an object, various cortical areas in the parietal and frontal lobes work together effortlessly to analyze object shape and position, transform this visual information into useful motor commands, and implement these motor representations to preshape the hand before contact with the object is made. In recent years, a growing number of studies have investigated the neural circuits underlying object grasping in both the visual and motor systems of the macaque monkey. The accumulated knowledge not only helps researchers understand how object grasping is implemented in the primate brain but may also contribute to the development of novel neural interfaces and neuroprosthetics.
The force synergy of human digits in static and dynamic cylindrical grasps.
Kuo, Li-Chieh; Chen, Shih-Wei; Lin, Chien-Ju; Lin, Wei-Jr; Lin, Sheng-Che; Su, Fong-Chin
2013-01-01
This study explores the force synergy of human digits in both static and dynamic cylindrical grasping conditions. The patterns of digit force distribution, error compensation, and the relationships among digit forces are examined to quantify the synergetic patterns and coordination of multi-finger movements. This study recruited 24 healthy participants to perform cylindrical grasps using a glass simulator under normal grasping and one-finger restricted conditions. Parameters such as the grasping force, patterns of digit force distribution, and the force coefficient of variation are determined. Correlation coefficients and principal component analysis (PCA) are used to estimate the synergy strength under the dynamic grasping condition. Specific distribution patterns of digit forces are identified for various conditions. The compensation of adjacent fingers for the force in the normal direction of an absent finger agrees with the principle of error compensation. For digit forces in anti-gravity directions, the distribution patterns vary significantly by participant. The forces exerted by the thumb are closely related to those exerted by other fingers under all conditions. The index-middle and middle-ring finger pairs demonstrate a significant relationship. The PCA results show that the normal forces of digits are highly coordinated. This study reveals that normal force synergy exists under both static and dynamic cylindrical grasping conditions.
The Force Synergy of Human Digits in Static and Dynamic Cylindrical Grasps
Kuo, Li-Chieh; Chen, Shih-Wei; Lin, Chien-Ju; Lin, Wei-Jr; Lin, Sheng-Che; Su, Fong-Chin
2013-01-01
This study explores the force synergy of human digits in both static and dynamic cylindrical grasping conditions. The patterns of digit force distribution, error compensation, and the relationships among digit forces are examined to quantify the synergetic patterns and coordination of multi-finger movements. This study recruited 24 healthy participants to perform cylindrical grasps using a glass simulator under normal grasping and one-finger restricted conditions. Parameters such as the grasping force, patterns of digit force distribution, and the force coefficient of variation are determined. Correlation coefficients and principal component analysis (PCA) are used to estimate the synergy strength under the dynamic grasping condition. Specific distribution patterns of digit forces are identified for various conditions. The compensation of adjacent fingers for the force in the normal direction of an absent finger agrees with the principle of error compensation. For digit forces in anti-gravity directions, the distribution patterns vary significantly by participant. The forces exerted by the thumb are closely related to those exerted by other fingers under all conditions. The index-middle and middle-ring finger pairs demonstrate a significant relationship. The PCA results show that the normal forces of digits are highly coordinated. This study reveals that normal force synergy exists under both static and dynamic cylindrical grasping conditions. PMID:23544151
Corrections in Grasp Posture in Response to Modifications of Action Goals
Hughes, Charmayne M. L.; Seegelke, Christian; Spiegel, Marnie Ann; Oehmichen, Corinna; Hammes, Julia; Schack, Thomas
2012-01-01
There is ample evidence that people plan their movements to ensure comfortable final grasp postures at the end of a movement. The end-state comfort effect has been found to be a robust constraint during unimanual movements, and leads to the inference that goal-postures are represented and planned prior to movement initiation. The purpose of this study was to examine whether individuals make appropriate corrections to ensure comfortable final goal postures when faced with an unexpected change in action goal. Participants reached for a horizontal cylinder and placed the left or right end of the object into the target disk. As soon as the participant began to move, a secondary stimuli was triggered, which indicated whether the intended action goal had changed or not. Confirming previous research, participants selected initial grasp postures that ensured end-state comfort during non-perturbed trials. In addition, participants made appropriate on-line corrections to their reach-to-grasp movements to ensure end-state comfort during perturbed trials. Corrections in grasp posture occurred early or late in the reach-to-grasp phase. The results indicate that individuals plan their movements to afford comfort at the end of the movement, and that grasp posture planning is controlled via both feedforward and feedback mechanisms. PMID:22970119
Wallace, Patricia S; Whishaw, Ian Q
2003-01-01
Previous work has described human reflexive grasp patterns in early infancy and visually guided reaching and grasping in late infancy. There has been no examination of hand movements in the intervening period. This was the purpose of the present study. We video recorded the spontaneous hand and digit movements made by alert infants over their first 5 months of age. Over this period, spontaneous hand and digit movements developed from fists to almost continuous, vacuous movements and then to self-directed grasping movements. Amongst the many hand and digit movements observed, four grasping patterns emerged during this period: fists, pre-precision grips associated with numerous digit postures, precision grips including the pincer grasp, and self-directed grasps. The finding that a wide range of independent digit movements and grasp patterns are displayed spontaneously by infants within their first 5 months of age is discussed in relation to the development of the motor system, including the suggestion that direct connections of the pyramidal tract are functional relatively early in infancy. It is also suggested that hand babbling, consisting of first vacuous and then self-directed movements, is preparatory to targeted reaching.
Herbort, Oliver; Büschelberger, Juliane; Janczyk, Markus
2018-03-01
In adults, the motor plans for object-directed grasping movements reflects the anticipated requirements of intended future object manipulations. This prospective mode of planning has been termed second-order planning. Surprisingly, second-order planning is thought to be fully developed only by 10 years of age, when children master seemingly more complex motor skills. In this study, we tested the hypothesis that already 5- and 6-year-old children consistently use second-order planning but that this ability does not become apparent in tasks that are traditionally used to probe it. We asked 5- and 6-year-olds and adults to grasp and rotate a circular dial in a clockwise or counterclockwise direction. Although children's grasp selections were less consistent on an intra- and inter-individual level than adults' grasp selections, all children adjusted their grasps to the upcoming dial rotations. By contrast, in an also administered bar rotation task, only a subset of children adjusted their grasps to different bar rotations, thereby replicating previous results. The results indicate that 5- and 6-year-olds consistently use second-order planning in a dial rotation task, although this ability does not become apparent in bar rotation tasks. Copyright © 2017 Elsevier Inc. All rights reserved.
Low-cost Solar Array (LSA) project
NASA Technical Reports Server (NTRS)
1978-01-01
Progress made by the Low-Cost Silicon Solar Array Project during the period January through March 1978 is reported. It includes task reports on silicon material processing, large-area silicon sheet development, encapsulation materials testing and development, project engineering and operations, and manufacturing techniques, plus the steps taken to integrate these efforts.
Hook, Sharon E.; Skillman, Ann D.; Small, Jack A.; Schultz, Irvin R.
2008-01-01
The increased availability and use of DNA microarrays has allowed the characterization of gene expression patterns associated with exposure to different toxicants. An important question is whether toxicant induced changes in gene expression in fish are sufficiently diverse to allow for identification of specific modes of action and/or specific contaminants. In theory, each class of toxicant may generate a gene expression profile unique to its mode of toxic action. In this study, isogenic (cloned) rainbow trout Oncorhynchus mykiss were exposed to sublethal levels of a series of model toxicants with varying modes of action, including ethynylestradiol (xeno-estrogen), 2,2,4,4′-tetrabromodiphenyl ether (BDE-47, thyroid active), diquat (oxidant stressor), chromium VI, and benzo[a]pyrene (BaP) for a period of 1–3 weeks. An additional experiment measured trenbolone (anabolic steroid; model androgen) induced gene expression changes in sexually mature female trout. Following exposure, fish were euthanized, livers removed and RNA extracted. Fluorescently labeled cDNA were generated and hybridized against a commercially available Atlantic Salmon/Trout array (GRASP project, University of Victoria) spotted with 16,000 cDNA’s. The slides were scanned to measure abundance of a given transcript in each sample relative to controls. Data were analyzed via Genespring (Silicon Genetics) to identify a list of up- and downregulated genes, as well as to determine gene clustering patterns that can be used as “expression signatures”. The results indicate each toxicant exposure caused between 64 and 222 genes to be significantly altered in expression. Most genes exhibiting altered expression responded to only one of the toxicants and relatively few were co-expressed in multiple treatments. For example, BaP and Diquat, both of which exert toxicity via oxidative stress, upregulated 28 of the same genes, of over 100 genes altered by either treatment. Other genes associated with steroidogenesis, p450 and estrogen responsive genes appear to be useful for selectively identifying toxicant mode of action in fish, suggesting a link between gene expression profile and mode of toxicity. Our array results showed good agreement with quantitative real time polymerase chain reaction (qRT PCR), which demonstrates that the arrays are an accurate measure of gene expression. The specificity of the gene expression profile in response to a model toxicant, the link between genes with altered expression and mode of toxic action, and the consistency between array and qRT PCR results all suggest that cDNA microarrays have the potential to screen environmental contaminants for biomarkers and mode of toxic action. PMID:16488489
Hook, Sharon E; Skillman, Ann D; Small, Jack A; Schultz, Irvin R
2006-05-25
The increased availability and use of DNA microarrays has allowed the characterization of gene expression patterns associated with exposure to different toxicants. An important question is whether toxicant induced changes in gene expression in fish are sufficiently diverse to allow for identification of specific modes of action and/or specific contaminants. In theory, each class of toxicant may generate a gene expression profile unique to its mode of toxic action. In this study, isogenic (cloned) rainbow trout Oncorhynchus mykiss were exposed to sublethal levels of a series of model toxicants with varying modes of action, including ethynylestradiol (xeno-estrogen), 2,2,4,4'-tetrabromodiphenyl ether (BDE-47, thyroid active), diquat (oxidant stressor), chromium VI, and benzo[a]pyrene (BaP) for a period of 1-3 weeks. An additional experiment measured trenbolone (anabolic steroid; model androgen) induced gene expression changes in sexually mature female trout. Following exposure, fish were euthanized, livers removed and RNA extracted. Fluorescently labeled cDNA were generated and hybridized against a commercially available Atlantic Salmon/Trout array (GRASP project, University of Victoria) spotted with 16,000 cDNA's. The slides were scanned to measure abundance of a given transcript in each sample relative to controls. Data were analyzed via Genespring (Silicon Genetics) to identify a list of up- and downregulated genes, as well as to determine gene clustering patterns that can be used as "expression signatures". The results indicate each toxicant exposure caused between 64 and 222 genes to be significantly altered in expression. Most genes exhibiting altered expression responded to only one of the toxicants and relatively few were co-expressed in multiple treatments. For example, BaP and Diquat, both of which exert toxicity via oxidative stress, upregulated 28 of the same genes, of over 100 genes altered by either treatment. Other genes associated with steroidogenesis, p450 and estrogen responsive genes appear to be useful for selectively identifying toxicant mode of action in fish, suggesting a link between gene expression profile and mode of toxicity. Our array results showed good agreement with quantitative real time polymerase chain reaction (qRT PCR), which demonstrates that the arrays are an accurate measure of gene expression. The specificity of the gene expression profile in response to a model toxicant, the link between genes with altered expression and mode of toxic action, and the consistency between array and qRT PCR results all suggest that cDNA microarrays have the potential to screen environmental contaminants for biomarkers and mode of toxic action.
Osumi, Michihiro; Sumitani, Masahiko; Otake, Yuko; Morioka, Shu
2018-01-01
Pain-related fear can exacerbate physical disability and pathological pain in complex regional pain syndrome (CRPS) patients. We conducted a kinematic analysis of grasping movements with a pediatric patient suffering from CRPS in an upper limb to investigate how pain-related fear affects motor control. Using a three-dimensional measurement system, we recorded the patient's movement while grasping three vertical bars of different diameters (thin, middle, thick) with the affected and intact hands. We analyzed the maximum grasp distance between the thumb and the index finger (MGD), the peak velocity of the grasp movement (PV), and the time required for the finger opening phase (TOP) and closing phase (TCP). Consequently, the MGD and PV of grasp movements in the affected hand were significantly smaller than those of the intact hand when grasping the middle and thick bars. This might reflect pain-related fear against visual information of the target size which evokes sensation of difficulty in opening fingers widely to grasp the middle and thick bars. Although MGD and PV increased with target size, the TOP was longer in the affected hand when grasping the thick bar. These findings indicate that pain-related fear impairs motor commands that are sent to the musculoskeletal system, subsequently disrupting executed movements and their sensory feedback. Using kinematic analysis, we objectively demonstrated that pain-related fear affects the process of sending motor commands towards the musculoskeletal system in the CRPS-affected hand, providing a possible explanatory model of pathological pain. Copyright © 2017 Elsevier Ltd. All rights reserved.
The Neural Correlates of Grasping in Left-Handers: When Handedness Does Not Matter.
Begliomini, Chiara; Sartori, Luisa; Di Bono, Maria G; Budisavljević, Sanja; Castiello, Umberto
2018-01-01
Neurophysiological studies showed that in macaques, grasp-related visuomotor transformations are supported by a circuit involving the anterior part of the intraparietal sulcus, the ventral and the dorsal region of the premotor area. In humans, a similar grasp-related circuit has been revealed by means of neuroimaging techniques. However, the majority of "human" studies considered movements performed by right-handers only, leaving open the question of whether the dynamics underlying motor control during grasping is simply reversed in left-handers with respect to right-handers or not. To address this question, a group of left-handed participants has been scanned with functional magnetic resonance imaging while performing a precision grasping task with the left or the right hand. Dynamic causal modeling was used to assess how brain regions of the two hemispheres contribute to grasping execution and whether the intra- and inter-hemispheric connectivity is modulated by the choice of the performing hand. Results showed enhanced inter-hemispheric connectivity between anterior intraparietal and dorsal premotor cortices during grasping execution with the left dominant hand (LDH) (e.g., right hemisphere) compared to the right (e.g., left hemisphere). These findings suggest that that the left hand, although dominant and theoretically more skilled in left handers, might need additional resources in terms of the visuomotor control and on-line monitoring to accomplish a precision grasping movement. The results are discussed in light of theories on the modulation of parieto-frontal networks during the execution of prehensile movements, providing novel evidence supporting the hypothesis of a handedness-independent specialization of the left hemisphere in visuomotor control.
Patterns of muscle activity underlying object-specific grasp by the macaque monkey.
Brochier, T; Spinks, R L; Umilta, M A; Lemon, R N
2004-09-01
During object grasp, a coordinated activation of distal muscles is required to shape the hand in relation to the physical properties of the object. Despite the fundamental importance of the grasping action, little is known of the muscular activation patterns that allow objects of different sizes and shapes to be grasped. In a study of two adult macaque monkeys, we investigated whether we could distinguish between EMG activation patterns associated with grasp of 12 differently shaped objects, chosen to evoke a wide range of grasping postures. Each object was mounted on a horizontal shuttle held by a weak spring (load force 1-2 N). Objects were located in separate sectors of a "carousel," and inter-trial rotation of the carousel allowed sequential presentation of the objects in pseudorandom order. EMG activity from 10 to 12 digit, hand, and arm muscles was recorded using chronically implanted electrodes. We show that the grasp of different objects was characterized by complex but distinctive patterns of EMG activation. Cluster analysis shows that these object-related EMG patterns were specific and consistent enough to identify the object unequivocally from the EMG recordings alone. EMG-based object identification required a minimum of six EMGs from simultaneously recorded muscles. EMG patterns were consistent across recording sessions in a given monkey but showed some differences between animals. These results identify the specific patterns of activity required to achieve distinct hand postures for grasping, and they open the way to our understanding of how these patterns are generated by the central motor network.
Biclustering of gene expression data using reactive greedy randomized adaptive search procedure
Dharan, Smitha; Nair, Achuthsankar S
2009-01-01
Background Biclustering algorithms belong to a distinct class of clustering algorithms that perform simultaneous clustering of both rows and columns of the gene expression matrix and can be a very useful analysis tool when some genes have multiple functions and experimental conditions are diverse. Cheng and Church have introduced a measure called mean squared residue score to evaluate the quality of a bicluster and has become one of the most popular measures to search for biclusters. In this paper, we review basic concepts of the metaheuristics Greedy Randomized Adaptive Search Procedure (GRASP)-construction and local search phases and propose a new method which is a variant of GRASP called Reactive Greedy Randomized Adaptive Search Procedure (Reactive GRASP) to detect significant biclusters from large microarray datasets. The method has two major steps. First, high quality bicluster seeds are generated by means of k-means clustering. In the second step, these seeds are grown using the Reactive GRASP, in which the basic parameter that defines the restrictiveness of the candidate list is self-adjusted, depending on the quality of the solutions found previously. Results We performed statistical and biological validations of the biclusters obtained and evaluated the method against the results of basic GRASP and as well as with the classic work of Cheng and Church. The experimental results indicate that the Reactive GRASP approach outperforms the basic GRASP algorithm and Cheng and Church approach. Conclusion The Reactive GRASP approach for the detection of significant biclusters is robust and does not require calibration efforts. PMID:19208127
NASA Technical Reports Server (NTRS)
Christensen, Elmer
1985-01-01
The Flat-Plate Solar Array (FSA) Project, a Government-sponsored photovoltaics project, was initiated in January 1975 (previously named the Low-Cost Silicon Solar Array Project) to stimulate the development of PV systems for widespread use. Its goal then was to develop PV modules with 10% efficiency, a 20-year lifetime, and a selling price of $0.50 per peak watt of generating capacity (1975 dollars). It was recognized that cost reduction of PV solar-cell and module manufacturing was the key achievement needed if PV power systems were to be economically competitive for large-scale terrestrial use.
Vorontsov, Mikhail; Filimonov, Grigory; Ovchinnikov, Vladimir; Polnau, Ernst; Lachinova, Svetlana; Weyrauch, Thomas; Mangano, Joseph
2016-05-20
The performance of two prominent laser beam projection system types is analyzed through wave-optics numerical simulations for various atmospheric turbulence conditions, propagation distances, and adaptive optics (AO) mitigation techniques. Comparisons are made between different configurations of both a conventional beam director (BD) using a monolithic-optics-based Cassegrain telescope and a fiber-array BD that uses an array of densely packed fiber collimators. The BD systems considered have equal input power and aperture diameters. The projected laser beam power inside the Airy size disk at the target plane is used as the performance metric. For the fiber-array system, both incoherent and coherent beam combining regimes are considered. We also present preliminary results of side-by-side atmospheric beam projection experiments over a 7-km propagation path using both the AO-enhanced beam projection system with a Cassegrain telescope and the coherent fiber-array BD composed of 21 densely packed fiber collimators. Both wave-optics numerical simulation and experimental results demonstrate that, for similar system architectures and turbulence conditions, coherent fiber-array systems are more efficient in mitigation of atmospheric turbulence effects and generation of a hit spot of the smallest possible size on a remotely located target.
Adaptive Force Control in Grasping as a Function of Level of Developmental Disability
ERIC Educational Resources Information Center
Sprague, R. L.; Deutsch, K. M.; Newell, K. M.
2009-01-01
Background: The adaptation to the task demands of grasping (grip mode and object mass) was investigated as a function of level of developmental disability. Methods: Subjects grasped objects of different grip widths and masses that were instrumented to record grip forces. Results: Proportionally, fewer participants from the profound compared with…
Short-Term Plasticity of the Visuomotor Map during Grasping Movements in Humans
ERIC Educational Resources Information Center
Safstrom, Daniel; Edin, Benoni B.
2005-01-01
During visually guided grasping movements, visual information is transformed into motor commands. This transformation is known as the "visuomotor map." To investigate limitations in the short-term plasticity of the visuomotor map in normal humans, we studied the maximum grip aperture (MGA) during the reaching phase while subjects grasped objects…
Lanzilotto, Marco; Livi, Alessandro; Maranesi, Monica; Gerbella, Marzio; Barz, Falk; Ruther, Patrick; Fogassi, Leonardo; Rizzolatti, Giacomo; Bonini, Luca
2016-12-01
Grasping relies on a network of parieto-frontal areas lying on the dorsolateral and dorsomedial parts of the hemispheres. However, the initiation and sequencing of voluntary actions also requires the contribution of mesial premotor regions, particularly the pre-supplementary motor area F6. We recorded 233 F6 neurons from 2 monkeys with chronic linear multishank neural probes during reaching-grasping visuomotor tasks. We showed that F6 neurons play a role in the control of forelimb movements and some of them (26%) exhibit visual and/or motor specificity for the target object. Interestingly, area F6 neurons form 2 functionally distinct populations, showing either visually-triggered or movement-related bursts of activity, in contrast to the sustained visual-to-motor activity displayed by ventral premotor area F5 neurons recorded in the same animals and with the same task during previous studies. These findings suggest that F6 plays a role in object grasping and extend existing models of the cortical grasping network. © The Author 2016. Published by Oxford University Press.
LIGHTWEIGHT INTEGRATED SOLAR ARRAY AND TRANSCEIVER
2016-09-23
JOHN CARR, RIGHT, CO-PRINCIPAL INVESTIGATOR FOR NASA'S LIGHTWEIGHT INTEGRATED SOLAR ARRAY AND TRANSCEIVER PROJECT, TALKS WITH GREG LAUE, DIRECTOR OF AEROSPACE PRODUCTS FOR NEXOLVE, MANUFACTURER OF THE THIN-FILM TECHNOLOGY AND A PARTNER IN THE PROJECT.
Mirror neurons encode the subjective value of an observed action.
Caggiano, Vittorio; Fogassi, Leonardo; Rizzolatti, Giacomo; Casile, Antonino; Giese, Martin A; Thier, Peter
2012-07-17
Objects grasped by an agent have a value not only for the acting agent, but also for an individual observing the grasping act. The value that the observer attributes to the object that is grasped can be pivotal for selecting a possible behavioral response. Mirror neurons in area F5 of the monkey premotor cortex have been suggested to play a crucial role in the understanding of action goals. However, it has not been addressed if these neurons are also involved in representing the value of the grasped object. Here we report that observation-related neuronal responses of F5 mirror neurons are indeed modulated by the value that the monkey associates with the grasped object. These findings suggest that during action observation F5 mirror neurons have access to key information needed to shape the behavioral responses of the observer.
Demonstration of KHILS two-color IR projection capability
NASA Astrophysics Data System (ADS)
Jones, Lawrence E.; Coker, Jason S.; Garbo, Dennis L.; Olson, Eric M.; Murrer, Robert Lee, Jr.; Bergin, Thomas P.; Goldsmith, George C., II; Crow, Dennis R.; Guertin, Andrew W.; Dougherty, Michael; Marler, Thomas M.; Timms, Virgil G.
1998-07-01
For more than a decade, there has been considerable discussion about using different IR bands for the detection of low contrast military targets. Theory predicts that a target can have little to no contrast against the background in one IR band while having a discernible signature in another IR band. A significant amount of effort has been invested towards establishing hardware that is capable of simultaneously imaging in two IR bands to take advantage of this phenomenon. Focal plane arrays (FPA) are starting to materialize with this simultaneous two-color imaging capability. The Kinetic Kill Vehicle Hardware-in-the-loop Simulator (KHILS) team of the Air Force Research Laboratory and the Guided Weapons Evaluation Facility (GWEF), both at Eglin AFB, FL, have spent the last 10 years developing the ability to project dynamic IR scenes to imaging IR seekers. Through the Wideband Infrared Scene Projector (WISP) program, the capability to project two simultaneous IR scenes to a dual color seeker has been established at KHILS. WISP utilizes resistor arrays to produce the IR energy. Resistor arrays are not ideal blackbodies. The projection of two IR colors with resistor arrays, therefore, requires two optically coupled arrays. This paper documents the first demonstration of two-color simultaneous projection at KHILS. Agema cameras were used for the measurements. The Agema's HgCdTe detector has responsivity from 4 to 14 microns. A blackbody and two IR filters (MWIR equals 4.2 t 7.4 microns, LWIR equals 7.7 to 13 microns) were used to calibrate the Agema in two bands. Each filter was placed in front of the blackbody one at a time, and the temperature of the blackbody was stepped up in incremental amounts. The output counts from the Agema were recorded at each temperature. This calibration process established the radiance to Agema output count curves for the two bands. The WISP optical system utilizes a dichroic beam combiner to optically couple the two resistor arrays. The transmission path of the beam combiner provided the LWIR (6.75 to 12 microns), while the reflective path produced the MWIR (3 to 6.5 microns). Each resistor array was individually projected into the Agema through the beam combiner at incremental output levels. Once again the Agema's output counts were recorded at each resistor array output level. These projections established the resistor array output to Agema count curves for the MWIR and LWIR resistor arrays. Using the radiance to Agema counts curves, the MWIR and LWIR resistor array output to radiance curves were established. With the calibration curves established, a two-color movie was projected and compared to the generated movie radiance values. By taking care to correctly account for the spectral qualities of the Agema camera, the calibration filters, and the diachroic beam combiner, the projections matched the theoretical calculations. In the near future, a Lockheed- Martin Multiple Quantum Well camera with true two-color IR capability will be tested.
Yun, M H; Cannon, D; Freivalds, A; Thomas, G
1997-10-01
Hand posture and force, which define aspects of the way an object is grasped, are features of robotic manipulation. A means for specifying these grasping "flavors" has been developed that uses an instrumented glove equipped with joint and force sensors. The new grasp specification system will be used at the Pennsylvania State University (Penn State) in a Virtual Reality based Point-and-Direct (VR-PAD) robotics implementation. Here, an operator gives directives to a robot in the same natural way that human may direct another. Phrases such as "put that there" cause the robot to define a grasping strategy and motion strategy to complete the task on its own. In the VR-PAD concept, pointing is done using virtual tools such that an operator can appear to graphically grasp real items in live video. Rather than requiring full duplication of forces and kinesthetic movement throughout a task as is required in manual telemanipulation, hand posture and force are now specified only once. The grasp parameters then become object flavors. The robot maintains the specified force and hand posture flavors for an object throughout the task in handling the real workpiece or item of interest. In the Computer integrated Manufacturing (CIM) Laboratory at Penn State, hand posture and force data were collected for manipulating bricks and other items that require varying amounts of force at multiple pressure points. The feasibility of measuring desired grasp characteristics was demonstrated for a modified Cyberglove impregnated with Force-Sensitive Resistor (FSR) (pressure sensors in the fingertips. A joint/force model relating the parameters of finger articulation and pressure to various lifting tasks was validated for the instrumented "wired" glove. Operators using such a modified glove may ultimately be able to configure robot grasping tasks in environments involving hazardous waste remediation, flexible manufacturing, space operations and other flexible robotics applications. In each case, the VR-PAD approach will finesse the computational and delay problems of real-time multiple-degree-of-freedom force feedback telemanipulation.
Freud, Erez; Macdonald, Scott N; Chen, Juan; Quinlan, Derek J; Goodale, Melvyn A; Culham, Jody C
2018-01-01
In the current era of touchscreen technology, humans commonly execute visually guided actions directed to two-dimensional (2D) images of objects. Although real, three-dimensional (3D), objects and images of the same objects share high degree of visual similarity, they differ fundamentally in the actions that can be performed on them. Indeed, previous behavioral studies have suggested that simulated grasping of images relies on different representations than actual grasping of real 3D objects. Yet the neural underpinnings of this phenomena have not been investigated. Here we used functional magnetic resonance imaging (fMRI) to investigate how brain activation patterns differed for grasping and reaching actions directed toward real 3D objects compared to images. Multivoxel Pattern Analysis (MVPA) revealed that the left anterior intraparietal sulcus (aIPS), a key region for visually guided grasping, discriminates between both the format in which objects were presented (real/image) and the motor task performed on them (grasping/reaching). Interestingly, during action planning, the representations of real 3D objects versus images differed more for grasping movements than reaching movements, likely because grasping real 3D objects involves fine-grained planning and anticipation of the consequences of a real interaction. Importantly, this dissociation was evident in the planning phase, before movement initiation, and was not found in any other regions, including motor and somatosensory cortices. This suggests that the dissociable representations in the left aIPS were not based on haptic, motor or proprioceptive feedback. Together, these findings provide novel evidence that actions, particularly grasping, are affected by the realness of the target objects during planning, perhaps because real targets require a more elaborate forward model based on visual cues to predict the consequences of real manipulation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Analysis of Hand and Wrist Postural Synergies in Tolerance Grasping of Various Objects
Liu, Yuan; Jiang, Li; Yang, Dapeng; Liu, Hong
2016-01-01
Human can successfully grasp various objects in different acceptable relative positions between human hand and objects. This grasp functionality can be described as the grasp tolerance of human hand, which is a significant functionality of human grasp. To understand the motor control of human hand completely, an analysis of hand and wrist postural synergies in tolerance grasping of various objects is needed. Ten healthy right-handed subjects were asked to perform the tolerance grasping with right hand using 6 objects of different shapes, sizes and relative positions between human hand and objects. Subjects were wearing CyberGlove attaching motion tracker on right hand, allowing a measurement of the hand and wrist postures. Correlation analysis of joints and inter-joint/inter-finger modules were carried on to explore the coordination between joints or modules. As the correlation between hand and wrist module is not obvious in tolerance grasping, individual analysis of wrist synergies would be more practical. In this case, postural synergies of hand and wrist were then presented separately through principal component analysis (PCA), expressed through the principal component (PC) information transmitted ratio, PC elements distribution and reconstructed angle error of joints. Results on correlation comparison of different module movements can be well explained by the influence factors of the joint movement correlation. Moreover, correlation analysis of joints and modules showed the wrist module had the lowest correlation among all inter-finger and inter-joint modules. Hand and wrist postures were both sufficient to be described by a few principal components. In terms of the PC elements distribution of hand postures, compared with previous investigations, there was a greater proportion of movement in the thumb joints especially the interphalangeal (IP) and opposition rotation (ROT) joint. The research could serve to a complete understanding of hand grasp, and the design, control of the anthropomorphic hand and wrist. PMID:27580298
Mine drainage control - design for reclamation and neutralization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koehrsen, L.G.; Grandt, A.F.
1970-01-01
The Peabody Coal Company Mine Drainage Neutralization Plant at the Will Scarlet mine is a versatile, full-scale facility which should add much new dimension to the science of dealing with this troublesome waste in the next several years. Hopefully, this brief outline will give other persons concerned with the mine drainage neutralization a grasp of the scope of the Peabody Research Program. It is our plan to follow this background presentation in another year with discussion of the effectiveness of the research project and the results that have been achieved. The research project reported herein is supported in part bymore » Federal Water Pollution Control Administration Research and Development Grant 14010 DAX.« less
NASA Technical Reports Server (NTRS)
Hinnant, Howard E.; Hodges, Dewey H.
1987-01-01
The General Rotorcraft Aeromechanical Stability Program (GRASP) was developed to analyse the steady-state and linearized dynamic behavior of rotorcraft in hovering and axial flight conditions. Because of the nature of problems GRASP was created to solve, the geometrically nonlinear behavior of beams is one area in which the program must perform well in order to be of any value. Numerical results obtained from GRASP are compared to both static and dynamic experimental data obtained for a cantilever beam undergoing large displacements and rotations caused by deformations. The correlation is excellent in all cases.
Nathan, Dominic E; Johnson, Michelle J; McGuire, John R
2009-01-01
Hand and arm impairment is common after stroke. Robotic stroke therapy will be more effective if hand and upper-arm training is integrated to help users practice reaching and grasping tasks. This article presents the design, development, and validation of a low-cost, functional electrical stimulation grasp-assistive glove for use with task-oriented robotic stroke therapy. Our glove measures grasp aperture while a user completes simple-to-complex real-life activities, and when combined with an integrated functional electrical stimulator, it assists in hand opening and closing. A key function is a new grasp-aperture prediction model, which uses the position of the end-effectors of two planar robots to define the distance between the thumb and index finger. We validated the accuracy and repeatability of the glove and its capability to assist in grasping. Results from five nondisabled subjects indicated that the glove is accurate and repeatable for both static hand-open and -closed tasks when compared with goniometric measures and for dynamic reach-to-grasp tasks when compared with motion analysis measures. Results from five subjects with stroke showed that with the glove, they could open their hands but without it could not. We present a glove that is a low-cost solution for in vivo grasp measurement and assistance.
Different left brain regions are essential for grasping a tool compared with its subsequent use.
Randerath, Jennifer; Goldenberg, Georg; Spijkers, Will; Li, Yong; Hermsdörfer, Joachim
2010-10-15
Tool use engages a left hemispheric network including frontal, temporal and parietal regions. Patients with left brain lesions (LBD patients) exhibit deficits when demonstrating use of a single tool (apraxia). When attempting to use a tool, some apraxic patients show errors in the preceding grasping movement. Forty-two LBD patients and 18 healthy controls grasped individual tools and demonstrated their typical use. For patients with a tool use impairment (22), lesion analysis revealed a large area of overlap in the left hemisphere, mainly in the supramarginal gyrus (SMG). For patients with erroneous grasping (12), the lesion overlay showed overlaps in the left frontal and parietal cortices, especially in the inferior frontal gyrus (IFG) and the angular gyrus (ANG). However, contrasting lesions associated with impaired grasping versus tool use impairments reveal little overlap, limited to the inferior parietal cortex. Presumably the left IFG is involved in selection processes in the context of tool use, such as choosing a functional or non-functional grasping movement depending on the task and the online information about the tool's structure and orientation. The ANG might provide this grasp related information, which is relevant for the specific action. The contribution of the SMG to tool use involves more general principals, such as integrating online and learned tool use information into the action plan for the use movement. Copyright 2010 Elsevier Inc. All rights reserved.
Yamashita, Yasunobu; Ueda, Kazuki; Kawaji, Yuki; Tamura, Takashi; Itonaga, Masahiro; Yoshida, Takeichi; Maeda, Hiroki; Magari, Hirohito; Maekita, Takao; Iguchi, Mikitaka; Tamai, Hideyuki; Ichinose, Masao; Kato, Jun
2016-01-01
Background/Aims Transpapillary forceps biopsy is an effective diagnostic technique in patients with biliary stricture. This prospective study aimed to determine the usefulness of the wire-grasping method as a new technique for forceps biopsy. Methods Consecutive patients with biliary stricture or irregularities of the bile duct wall were randomly allocated to either the direct or wire-grasping method group. In the wire-grasping method, forceps in the duodenum grasps a guide-wire placed into the bile duct beforehand, and then, the forceps are pushed through the papilla without endoscopic sphincterotomy. In the direct method, forceps are directly pushed into the bile duct alongside a guide-wire. The primary endpoint was the success rate of obtaining specimens suitable for adequate pathological examination. Results In total, 32 patients were enrolled, and 28 (14 in each group) were eligible for analysis. The success rate was significantly higher using the wire-grasping method than the direct method (100% vs 50%, p=0.016). Sensitivity and accuracy for the diagnosis of cancer were comparable in patients with the successful procurement of biopsy specimens between the two methods (91% vs 83% and 93% vs 86%, respectively). Conclusions The wire-grasping method is useful for diagnosing patients with biliary stricture or irregularities of the bile duct wall. PMID:27021502
Flat-plate solar array project. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Callaghan, W.; Mcdonald, R.
1986-01-01
In 1975, the U.S. Government contracted the Jet Propulsion Lab. to develop, by 1985, in conjunction with industry, the photovoltaics (PV) module and array technology required for widespread use of photovoltaics as a significant terrestrial energy source. As a result, a project that eventually became known as the Flat Plate Solar Array (FSA) Project was formed to manage an industry, university, and Government team to perform the necessary research and development. The original goals were to achieve widespread commercial use of PV modules and arrays through the development of technology that would allow them to be profitably sold for $1.07/peak watts (1985 dollars). A 10% module conversion efficiency and a 20 year lifetime were also goals. It is intended that the executive summary provide the means by which one can gain a perspective on 11 years of terrestrial photovoltaic research and development conducted by the FSA Project.
Spatial light modulator array with heat minimization and image enhancement features
Jain, Kanti [Briarcliff Manor, NY; Sweatt, William C [Albuquerque, NM; Zemel, Marc [New Rochelle, NY
2007-01-30
An enhanced spatial light modulator (ESLM) array, a microelectronics patterning system and a projection display system using such an ESLM for heat-minimization and resolution enhancement during imaging, and the method for fabricating such an ESLM array. The ESLM array includes, in each individual pixel element, a small pixel mirror (reflective region) and a much larger pixel surround. Each pixel surround includes diffraction-grating regions and resolution-enhancement regions. During imaging, a selected pixel mirror reflects a selected-pixel beamlet into the capture angle of a projection lens, while the diffraction grating of the pixel surround redirects heat-producing unused radiation away from the projection lens. The resolution-enhancement regions of selected pixels provide phase shifts that increase effective modulation-transfer function in imaging. All of the non-selected pixel surrounds redirect all radiation energy away from the projection lens. All elements of the ESLM are fabricated by deposition, patterning, etching and other microelectronic process technologies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mosher, J.C.; Leahy, R.M.
A new method for source localization is described that is based on a modification of the well known multiple signal classification (MUSIC) algorithm. In classical MUSIC, the array manifold vector is projected onto an estimate of the signal subspace, but errors in the estimate can make location of multiple sources difficult. Recursively applied and projected (RAP) MUSIC uses each successively located source to form an intermediate array gain matrix, and projects both the array manifold and the signal subspace estimate into its orthogonal complement. The MUSIC projection is then performed in this reduced subspace. Using the metric of principal angles,more » the authors describe a general form of the RAP-MUSIC algorithm for the case of diversely polarized sources. Through a uniform linear array simulation, the authors demonstrate the improved Monte Carlo performance of RAP-MUSIC relative to MUSIC and two other sequential subspace methods, S and IES-MUSIC.« less
Nuclear Criticism after the Cold War: A Rhetorical Analysis of Two Contemporary Atomic Campaigns
1997-08-01
Craig & Jungerman, 1986). The implications of this fission were grasped by Leo Szilard and others that fission could result in the release of massive...research of Enrico Fermi and others to study the potential for sustained chained reactions 40 produced by an atomic "pile" ( Craig & Jungerman, 1986...project to build a hydrogen bomb began at the urging of Edward Teller and after the reservations of Oppenheimer, Fermi and others ( Craig & Jungerman, 1986
Compact intra-cavity frequency doubled line beam green laser by a laser diode array pumped
NASA Astrophysics Data System (ADS)
Yan, Boxia; Qi, Yan; Wang, Yanwei
2016-10-01
Compact, high power, and low-cost green laser light sources are needed in projection-related applications such as digital cinema, rear-projection television, simulators, and command and control stations. We report a LD array directly pumped intracavity SHG Nd:YVO4/PPMgLN laser without lens or waveguide in this letter. A compact 3.12 W green laser was demonstrated by intra-cavity frequency doubled using a PPMgLN bulk crystal by a 19-emitter LD array pumped(single bar), the conversion efficiency from input LD array was 9.2%. A line-beam output suitable for laser projectors was generated, which has the potential to be scalable to small volumes and low costs for laser projection displays.
Chandarana, Hersh; Feng, Li; Ream, Justin; Wang, Annie; Babb, James S; Block, Kai Tobias; Sodickson, Daniel K; Otazo, Ricardo
2015-01-01
Purpose Demonstrate feasibility of free-breathing radial acquisition with respiratory motion-resolved compressed sensing (CS) reconstruction (XD-GRASP) for multiphase dynamic Gd-EOB-DTPA enhanced liver imaging, and compare image quality to CS reconstruction with respiratory motion-averaging (GRASP) and prior conventional breath-held Cartesian-sampled datasets (BH-VIBE) in same patients. Subjects and Methods In this HIPAA-compliant prospective study, 16 subjects underwent free-breathing continuous radial acquisition during Gd-EOB-DTPA injection, and had prior BH-VIBE exam available. Acquired data were reconstructed using motion-averaging GRASP approach, in which consecutive 84-spokes were grouped in each contrast-enhanced phase for a temporal resolution of ~14 seconds. Additionally, respiratory motion-resolved reconstruction was performed from the same k-space data, by sorting each contrast-enhanced phase into multiple respiratory motion states using compressed sensing algorithm named XD-GRASP, which exploits sparsity along both the contrast-enhancement and respiratory-state dimensions. Contrast-enhanced dynamic multi-phase XD-GRASP, GRASP, and BH-VIBE images were anonymized, pooled together in a random order and presented to two board-certified radiologists for independent evaluation of image quality, with higher score indicating more optimal exam. Results XD-GRASP reconstructions had significantly (all p<0.05) higher overall image quality scores compared to GRASP for early arterial (Reader 1: 4.3 ± 0.6 vs. 3.31 ± 0.6 ; Reader 2: 3.81 ± 0.8 vs. 3.38 ± 0.9) and late arterial (Reader 1: 4.5 ± 0.6 vs. 3.63 ± 0.6; Reader 2: 3.56 ± 0.5 vs. 2.88 ± 0.7) phases of enhancement for both readers. XD-GRASP also had higher overall image quality score in portal venous phase which was significant for Reader 1 (4.44 ± 0.5 vs. 3.75 ± 0.8; p=0.002). In addition, XD-GRASP had higher overall image quality score compared to BH-VIBE for early (Reader 1: 4.3±0.6 vs. 3.88±0.6; Reader 2: 3.81±0.8 vs. 3.50±1.0) and late (Reader 1: 4.5±0.6 vs. 3.44±0.6; Reader 2: 3.56±0.5 vs. 2.94±0.9) arterial phases. Conclusion Free-breathing motion-resolved XD-GRASP reconstructions provide diagnostic high-quality multiphase images in patients undergoing Gd-EOB-DTPA-enhanced liver exam. PMID:26146869
Bone indicators of grasping hands in lizards
2016-01-01
Grasping is one of a few adaptive mechanisms that, in conjunction with clinging, hooking, arm swinging, adhering, and flying, allowed for incursion into the arboreal eco-space. Little research has been done that addresses grasping as an enhanced manual ability in non-mammalian tetrapods, with the exception of studies comparing the anatomy of muscle and tendon structure. Previous studies showed that grasping abilities allow exploitation for narrow branch habitats and that this adaptation has clear osteological consequences. The objective of this work is to ascertain the existence of morphometric descriptors in the hand skeleton of lizards related to grasping functionality. A morphological matrix was constructed using 51 morphometric variables in 278 specimens, from 24 genera and 13 families of Squamata. To reduce the dimensions of the dataset and to organize the original variables into a simpler system, three PCAs (Principal Component Analyses) were performed using the subsets of (1) carpal variables, (2) metacarpal variables, and (3) phalanges variables. The variables that demonstrated the most significant contributions to the construction of the PCA synthetic variables were then used in subsequent analyses. To explore which morphological variables better explain the variations in the functional setting, we ran Generalized Linear Models for the three different sets. This method allows us to model the morphology that enables a particular functional trait. Grasping was considered the only response variable, taking the value of 0 or 1, while the original variables retained by the PCAs were considered predictor variables. Our analyses yielded six variables associated with grasping abilities: two belong to the carpal bones, two belong to the metacarpals and two belong to the phalanges. Grasping in lizards can be performed with hands exhibiting at least two different independently originated combinations of bones. The first is a combination of a highly elongated centrale bone, reduced palmar sesamoid, divergence angles above 90°, and slender metacarpal V and phalanges, such as exhibited by Anolis sp. and Tropidurus sp. The second includes an elongated centrale bone, lack of a palmar sesamoid, divergence angles above 90°, and narrow metacarpal V and phalanges, as exhibited by geckos. Our data suggest that the morphological distinction between graspers and non-graspers is demonstrating the existence of ranges along the morphological continuum within which a new ability is generated. Our results support the hypothesis of the nested origin of grasping abilities within arboreality. Thus, the manifestation of grasping abilities as a response to locomotive selective pressure in the context of narrow-branch eco-spaces could also enable other grasping-dependent biological roles, such as prey handling. PMID:27168987
Jarque-Bou, N; Gracia-Ibáñez, V; Sancho-Bru, J L; Vergara, M; Pérez-González, A; Andrés, F J
2016-09-01
The kinematic analysis of human grasping is challenging because of the high number of degrees of freedom involved. The use of principal component and factorial analyses is proposed in the present study to reduce the hand kinematics dimensionality in the analysis of posture for ergonomic purposes, allowing for a comprehensive study without losing accuracy while also enabling velocity and acceleration analyses to be performed. A laboratory study was designed to analyse the effect of weight and diameter in the grasping posture for cylinders. This study measured the hand posture from six subjects when transporting cylinders of different weights and diameters with precision and power grasps. The hand posture was measured using a Vicon(®) motion-tracking system, and the principal component analysis was applied to reduce the kinematics dimensionality. Different ANOVAs were performed on the reduced kinematic variables to check the effect of weight and diameter of the cylinders, as well as that of the subject. The results show that the original twenty-three degrees of freedom of the hand were reduced to five, which were identified as digit arching, closeness, palmar arching, finger adduction and thumb opposition. Both cylinder diameter and weight significantly affected the precision grasping posture: diameter affects closeness, palmar arching and opposition, while weight affects digit arching, palmar arching and closeness. The power-grasping posture was mainly affected by the cylinder diameter, through digit arching, closeness and opposition. The grasping posture was largely affected by the subject factor and this effect couldn't be attributed only to hand size. In conclusion, this kinematic reduction allowed identifying the effect of the diameter and weight of the cylinders in a comprehensive way, being diameter more important than weight. Copyright © 2016 Elsevier Ltd. All rights reserved.
On the evolution of handedness: evidence for feeding biases.
Flindall, Jason W; Gonzalez, Claudia L R
2013-01-01
Many theories have been put forward to explain the origins of right-handedness in humans. Here we present evidence that this preference may stem in part from a right hand advantage in grasping for feeding. Thirteen participants were asked to reach-to-grasp food items of 3 different sizes: SMALL (Cheerios®), MEDIUM (Froot Loops®), and LARGE (Oatmeal Squares®). Participants used both their right- and left-hands in separate blocks (50 trials each, starting order counterbalanced) to grasp the items. After each grasp, participants either a) ate the food item, or b) placed it inside a bib worn beneath his/her chin (25 trials each, blocked design, counterbalanced). The conditions were designed such that the outward and inward movement trajectories were similar, differing only in the final step of placing it in the mouth or bib. Participants wore Plato liquid crystal goggles that blocked vision between trials. All trials were conducted in closed-loop with 5000 ms of vision. Hand kinematics were recorded by an Optotrak Certus, which tracked the position of three infrared diodes attached separately to the index finger, thumb, and wrist. We found a task (EAT/PLACE) by hand (LEFT/RIGHT) interaction on maximum grip aperture (MGA; the maximum distance between the index finger and thumb achieved during grasp pre-shaping). MGAs were smaller during right-handed movements, but only when grasping with intent to eat. Follow-up tests show that the RIGHT-HAND/EAT MGA was significantly smaller than all other hand/task conditions. Because smaller grip apertures are typically associated with greater precision, our results demonstrate a right-hand advantage for the grasp-to-eat movement. From an evolutionary perspective, early humans may have preferred the hand that could grasp food with more precision, thereby maximizing the likelihood of retrieval, consumption, and consequently, survival.
Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl; Chau, Tom
2012-06-01
To investigate the impact of common pencil grasp patterns on the speed and legibility of handwriting after a 10-minute copy task, intended to induce muscle fatigue, in typically developing children and in those non-proficient in handwriting. A total of 120 Grade 4 students completed a standardised handwriting assessment before and after a 10-minute copy task. The students indicated the perceived difficulty of the handwriting task at baseline and after 10 minutes. The students also completed a self-report questionnaire regarding their handwriting proficiency upon completion. The majority of the students rated higher effort after the 10-minute copy task than at baseline (rank sum: P = 0.00001). The effort ratings were similar for the different grasp patterns (multiple linear regression: F = 0.37, P = 0.895). For both typically developing children and those with handwriting issues, the legibility of the writing samples decreased after the 10-minute copy task but the speed of writing increased. CONCLUSIONS AND SIGNIFICANCE OF THE STUDY: The quality of the handwriting decreased after the 10-minute copy task; however, there was no difference in the quality or speed scores among the different pencil grasps before and after the copy task. The dynamic tripod pencil grasp did not offer any advantage over the lateral tripod or the dynamic or lateral quadrupod pencil grasps in terms of quality of handwriting after a 10-minute copy task. These four pencil grasp patterns performed equivalently. Our findings question the practice of having students adopt the dynamic tripod pencil grasp. © 2012 The Authors Australian Occupational Therapy Journal © 2012 Occupational Therapy Australia.
How Weight Affects the Perceived Spacing between the Thumb and Fingers during Grasping
Butler, Annie A.; Héroux, Martin E.; Gandevia, Simon C.
2015-01-01
We know much about mechanisms determining the perceived size and weight of lifted objects, but little about how these properties of size and weight affect the body representation (e.g. grasp aperture of the hand). Without vision, subjects (n = 16) estimated spacing between fingers and thumb (perceived grasp aperture) while lifting canisters of the same width (6.6cm) but varied weights (300, 600, 900, and 1200 g). Lifts were performed by movement of either the wrist, elbow or shoulder to examine whether lifting with different muscle groups affects the judgement of grasp aperture. Results for perceived grasp aperture were compared with changes in perceived weight of objects of different sizes (5.2, 6.6, and 10 cm) but the same weight (600 g). When canisters of the same width but different weights were lifted, perceived grasp aperture decreased 4.8% [2.2 ‒ 7.4] (mean [95% CI]; P < 0.001) from the lightest to the heaviest canister, no matter how they were lifted. For objects of the same weight but different widths, perceived weight decreased 42.3% [38.2 ‒ 46.4] from narrowest to widest (P < 0.001), as expected from the size-weight illusion. Thus, despite a highly distorted perception of the weight of objects based on their size, we conclude that proprioceptive afferents maintain a reasonably stable perception of the aperture of the grasping hand over a wide range of object weights. Given the small magnitude of this ‘weight-grasp aperture’ illusion, we propose the brain has access to a relatively stable ‘perceptual ruler’ to aid the manipulation of different objects. PMID:25996760
Adaptive and mobile ground sensor array.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holzrichter, Michael Warren; O'Rourke, William T.; Zenner, Jennifer
The goal of this LDRD was to demonstrate the use of robotic vehicles for deploying and autonomously reconfiguring seismic and acoustic sensor arrays with high (centimeter) accuracy to obtain enhancement of our capability to locate and characterize remote targets. The capability to accurately place sensors and then retrieve and reconfigure them allows sensors to be placed in phased arrays in an initial monitoring configuration and then to be reconfigured in an array tuned to the specific frequencies and directions of the selected target. This report reviews the findings and accomplishments achieved during this three-year project. This project successfully demonstrated autonomousmore » deployment and retrieval of a payload package with an accuracy of a few centimeters using differential global positioning system (GPS) signals. It developed an autonomous, multisensor, temporally aligned, radio-frequency communication and signal processing capability, and an array optimization algorithm, which was implemented on a digital signal processor (DSP). Additionally, the project converted the existing single-threaded, monolithic robotic vehicle control code into a multi-threaded, modular control architecture that enhances the reuse of control code in future projects.« less
Mirror neurons encode the subjective value of an observed action
Caggiano, Vittorio; Fogassi, Leonardo; Rizzolatti, Giacomo; Casile, Antonino; Giese, Martin A.; Thier, Peter
2012-01-01
Objects grasped by an agent have a value not only for the acting agent, but also for an individual observing the grasping act. The value that the observer attributes to the object that is grasped can be pivotal for selecting a possible behavioral response. Mirror neurons in area F5 of the monkey premotor cortex have been suggested to play a crucial role in the understanding of action goals. However, it has not been addressed if these neurons are also involved in representing the value of the grasped object. Here we report that observation-related neuronal responses of F5 mirror neurons are indeed modulated by the value that the monkey associates with the grasped object. These findings suggest that during action observation F5 mirror neurons have access to key information needed to shape the behavioral responses of the observer. PMID:22753471
Design of precise assembly equipment of large aperture optics
NASA Astrophysics Data System (ADS)
Pei, Guoqing; Xu, Xu; Xiong, Zhao; Yan, Han; Qin, Tinghai; Zhou, Hai; Yuan, Xiaodong
2017-05-01
High-energy solid-state laser is an important way to achieve laser fusion research. Laser fusion facility includes thousands of various types of large aperture optics. These large aperture optics should be assembled with high precision and high efficiency. Currently, however, the assembly of large aperture optics is by man's hand which is in low level of efficiency and labor-intensive. Here, according to the characteristics of the assembly of large aperture optics, we designed three kinds of grasping devices. Using Finite Element Method, we simulated the impact of the grasping device on the PV value and the RMS value of the large aperture optics. The structural strength of the grasping device's key part was analyzed. An experiment was performed to illustrate the reliability and precision of the grasping device. We anticipate that the grasping device would complete the assembly of large aperture optics precisely and efficiently.
Manipulation of Unknown Objects to Improve the Grasp Quality Using Tactile Information.
Montaño, Andrés; Suárez, Raúl
2018-05-03
This work presents a novel and simple approach in the area of manipulation of unknown objects considering both geometric and mechanical constraints of the robotic hand. Starting with an initial blind grasp, our method improves the grasp quality through manipulation considering the three common goals of the manipulation process: improving the hand configuration, the grasp quality and the object positioning, and, at the same time, prevents the object from falling. Tactile feedback is used to obtain local information of the contacts between the fingertips and the object, and no additional exteroceptive feedback sources are considered in the approach. The main novelty of this work lies in the fact that the grasp optimization is performed on-line as a reactive procedure using the tactile and kinematic information obtained during the manipulation. Experimental results are shown to illustrate the efficiency of the approach.
Control of a Glove-Based Grasp Assist Device
NASA Technical Reports Server (NTRS)
Bergelin, Bryan J (Inventor); Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Linn, Douglas Martin (Inventor); Sanders, Adam M (Inventor); Askew, R. Scott (Inventor); Laske, Evan (Inventor); Ensley, Kody (Inventor)
2015-01-01
A grasp assist system includes a glove and sleeve. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. The glove contains a tendon connected at a first end to the digit. The sleeve has an actuator assembly connected to a second end of the tendon and a controller in communication with the sensor. The controller includes a configuration module having selectable operating modes and a processor that calculates a tensile force to apply to the tendon for each of the selectable operating modes to assist the grasping force in a manner that differs for each of the operating modes. A method includes measuring the grasping force, selecting the mode, calculating the tensile force, and applying the tensile force to the tendon using the actuator assembly.
An effective 3-fingered augmenting exoskeleton for the human hand.
Gearhart, C J; Varone, B; Stella, M H; BuSha, B F
2016-08-01
Every year, thousands of Americans suffer from pathological and traumatic events that result in loss of dexterity and strength of the hand. Although many supportive devices have been designed to restore functional hand movement, most are very complex and expensive. The goal of this project was to design and implement a cost-effective, electrically powered exoskeleton for the human hand that could improve grasping strength. A 3-D printed thermoplastic exoskeleton that allowed independent and enhanced movement of the index, middle and ring fingers was constructed. In addition, a 3-D printed structure was designed to house three linear actuators, an Arduino-based control system, and a power supply. A single force sensing resistor was located on the lower inner-surface of the index fingertip which was used to proportionally activate the three motors, one motor per finger, as a function of finger force applied to the sensor. The device was tested on 4 normal human subjects. Results showed that the activation of the motor control system significantly reduced the muscle effort needed to maintain a sub-maximal grasp effort.
7 degree-of-freedom neuroprosthetic control by an individual with tetraplegia
Collinger, Jennifer L; Wodlinger, Brian; Downey, John E; Wang, Wei; Tyler-Kabara, Elizabeth C; Weber, Douglas J; McMorland, Angus JC; Velliste, Meel; Boninger, Michael L; Schwartz, Andrew B
2013-01-01
SUMMARY Background We use our arms to transport and orient the hand which is used to grasp and manipulate objects. Upper limb paralysis or amputation limits a person’s ability to interact with their environment to accomplish activities of daily living. Brain-machine interfaces (BMIs) may provide a solution to restoring much of this function. Methods Two 96-channel intracortical microelectrodes were implanted in the motor cortex of an individual with tetraplegia. Thirteen weeks of BMI training were conducted with the goal of controlling an anthropomorphic prosthetic limb with 7 degrees-of-freedom (3D translation, 3D orientation, 1D grasping). Clinical measures of upper-limb function were used to assess the participant’s ability to use the prosthetic limb. Findings The participant demonstrated the ability to move the device freely in the three-dimensional (3D) workspace on the second day of training. After 13 weeks, robust 7 degree-of-freedom movements were performed routinely. Over time, performance on target-based reaching tasks improved in terms of success rate, completion time, and path efficiency. The participant was also able to use the prosthetic limb to perform skillful and coordinated reach and grasp movements that resulted in clinically significant gains in tests of upper-limb function. Interpretation This study demonstrates that a person with chronic tetraplegia can perform consistent, natural, and complex movements with an anthropomorphic robotic arm to regain clinically significant function. Funding Defense Advanced Research Projects Agency, National Institutes of Health, Department of Veterans Affairs, and UPMC Rehabilitation Institute PMID:23253623
NASA Technical Reports Server (NTRS)
1983-01-01
The Flat Plate Solar Array Project, focuses on advancing technologies relevant to the design and construction of megawatt level central station systems. Photovoltaic modules and arrays for flat plate central station or other large scale electric power production facilities require the establishment of a technical base that resolves design issues and results in practical and cost effective configurations. Design, qualification and maintenance issues related to central station arrays derived from the engineering and operating experiences of early applications and parallel laboratory reserch activities are investigated. Technical issues are examined from the viewpoint of the utility engineer, architect/engineer and laboratory researcher. Topics on optimum source circuit designs, module insulation design for high system voltages, array safety, structural interface design, measurements, and array operation and maintenance are discussed.
ERIC Educational Resources Information Center
Gentilucci, Maurizio; Campione, Giovanna Cristina; Volta, Riccardo Dalla; Bernardis, Paolo
2009-01-01
Does the mirror system affect the control of speech? This issue was addressed in behavioral and Transcranial Magnetic Stimulation (TMS) experiments. In behavioral experiment 1, participants pronounced the syllable /da/ while observing (1) a hand grasping large and small objects with power and precision grasps, respectively, (2) a foot interacting…
Development of Reaching and Grasping Skills in Infants with Down Syndrome
ERIC Educational Resources Information Center
de Campos, Ana Carolina; Rocha, Nelci Adriana Cicuto Ferreira; Savelsbergh, Geert J. P.
2010-01-01
Reaching and grasping skills have been described to emerge from a dynamic interaction between intrinsic and extrinsic factors. The aims of the study were to investigate the effect of such intrinsic factors as age and Down syndrome on the development of reaching and grasping skills and on overall gross motor skill, and to test the influence of the…
Fuzzy Logic Controller Design for A Robot Grasping System with Different Membership Functions
NASA Astrophysics Data System (ADS)
Ahmad, Hamzah; Razali, Saifudin; Rusllim Mohamed, Mohd
2013-12-01
This paper investigates the effects of the membership function to the object grasping for a three fingered gripper system. The performance of three famously used membership functions is compared to identify their behavior in lifting a defined object shape. MATLAB Simulink and SimMechanics toolboxes are used to examine the performance. Our preliminary results proposed that the Gaussian membership function surpassed the two other membership functions; triangular and trapezoid memberships especially in the context of firmer grasping and less time consumption during operations. Therefore, Gaussian membership function could be the best solution when time consumption and firmer grasp are considered.
An EMG-Controlled Robotic Hand Exoskeleton for Bilateral Rehabilitation.
Leonardis, Daniele; Barsotti, Michele; Loconsole, Claudio; Solazzi, Massimiliano; Troncossi, Marco; Mazzotti, Claudio; Castelli, Vincenzo Parenti; Procopio, Caterina; Lamola, Giuseppe; Chisari, Carmelo; Bergamasco, Massimo; Frisoli, Antonio
2015-01-01
This paper presents a novel electromyography (EMG)-driven hand exoskeleton for bilateral rehabilitation of grasping in stroke. The developed hand exoskeleton was designed with two distinctive features: (a) kinematics with intrinsic adaptability to patient's hand size, and (b) free-palm and free-fingertip design, preserving the residual sensory perceptual capability of touch during assistance in grasping of real objects. In the envisaged bilateral training strategy, the patient's non paretic hand acted as guidance for the paretic hand in grasping tasks. Grasping force exerted by the non paretic hand was estimated in real-time from EMG signals, and then replicated as robotic assistance for the paretic hand by means of the hand-exoskeleton. Estimation of the grasping force through EMG allowed to perform rehabilitation exercises with any, non sensorized, graspable objects. This paper presents the system design, development, and experimental evaluation. Experiments were performed within a group of six healthy subjects and two chronic stroke patients, executing robotic-assisted grasping tasks. Results related to performance in estimation and modulation of the robotic assistance, and to the outcomes of the pilot rehabilitation sessions with stroke patients, positively support validity of the proposed approach for application in stroke rehabilitation.
Instrumented toys for studying power and precision grasp forces in infants.
Serio, S M; Cecchi, F; Boldrini, E; Laschi, C; Sgandurra, G; Cioni, G; Dario, P
2011-01-01
Currently the study of infants grasping development is purely clinical, based on functional scales or on the observation of the infant while playing; no quantitative variables are measured or known for diagnosis of eventually disturbed development. The aim of this work is to show the results of a longitudinal study achieved by using a "baby gym" composed by a set of instrumented toys, as a tool to measure and stimulate grasping actions, in infants from 4 to 9 months of life. The study has been carried out with 7 healthy infants and it was observed, during infants development, an increase of precision grasp and a reduction of power grasp with age. Moreover the forces applied for performing both precision and power grasp increase with age. The proposed devices represent a valid tool for continuous and quantitative measuring infants manual function and motor development, without being distressful for the infant and consequently it could be suitable for early intervention training during the first year of life. The same system, in fact, could be used with infants at high risk for developmental motor disorder in order to evaluate any potential difference from control healthy infants.
LSSA (Low-cost Silicon Solar Array) project
NASA Technical Reports Server (NTRS)
1976-01-01
Methods are explored for economically generating electrical power to meet future requirements. The Low-Cost Silicon Solar Array Project (LSSA) was established to reduce the price of solar arrays by improving manufacturing technology, adapting mass production techniques, and promoting user acceptance. The new manufacturing technology includes the consideration of new silicon refinement processes, silicon sheet growth techniques, encapsulants, and automated assembly production being developed under contract by industries and universities.
Low cost silicon solar cell array
NASA Technical Reports Server (NTRS)
Bartels, F. T. C.
1974-01-01
The technological options available for producing low cost silicon solar cell arrays were examined. A project value of approximately $250/sq m and $2/watt is projected, based on mass production capacity demand. Recommendations are included for the most promising cost reduction options.
Dependence of behavioral performance on material category in an object grasping task with monkeys.
Yokoi, Isao; Tachibana, Atsumichi; Minamimoto, Takafumi; Goda, Naokazu; Komatsu, Hidehiko
2018-05-02
Material perception is an essential part of our cognitive function that enables us to properly interact with our complex daily environment. One important aspect of material perception is its multimodal nature. When we see an object, we generally recognize its haptic properties as well as its visual properties. Consequently, one must examine behavior using real objects that are perceived both visually and haptically to fully understand the characteristics of material perception. As a first step, we examined whether there is any difference in the behavioral responses to different materials in monkeys trained to perform an object grasping task in which they saw and grasped rod-shaped real objects made of various materials. We found that the monkeys' behavior in the grasping task, measured based on the success rate and the pulling force, differed depending on the material category. Monkeys easily and correctly grasped objects of some materials, such as metal and glass, but failed to grasp objects of other materials. In particular, monkeys avoided grasping fur-covered objects. The differences in the behavioral responses to the material categories cannot be explained solely based on the degree of familiarity with the different materials. These results shed light on the organization of multimodal representation of materials, where their biological significance is an important factor. In addition, a monkey that avoided touching real fur-covered objects readily touched images of the same objects presented on a CRT display. This suggests employing real objects is important when studying behaviors related to material perception.
The origins of thalamic inputs to grasp zones in frontal cortex of macaque monkeys
Stepniewska, Iwona; Kaas, Jon H.
2015-01-01
The hand representation in primary motor cortex (M1) is instrumental to manual dexterity in primates. In Old World monkeys, rostral and caudal aspects of the hand representation are located in the precentral gyrus and the anterior bank of the central sulcus, respectively. We previously reported the organization of the cortico-cortical connections of the grasp zone in rostral M1. Here we describe the organization of thalamocortical connections that were labeled from the same tracer injections. Thalamocortical connections of a grasp zone in ventral premotor cortex (PMv) and the M1 orofacial representation are included for direct comparison. The M1 grasp zone was primarily connected with ventral lateral divisions of motor thalamus. The largest proportion of inputs originated in the posterior division (VLp) followed by the medial and the anterior divisions. Thalamic inputs to the M1 grasp zone originated in more lateral aspects of VLp as compared to the origins of thalamic inputs to the M1 orofacial representation. Inputs to M1 from thalamic divisions connected with cerebellum constituted three fold the density of inputs from divisions connected with basal ganglia, whereas the ratio of inputs was more balanced for the grasp zone in PMv. Privileged access of the cerebellothalamic pathway to the grasp zone in rostral M1 is consistent with the connection patterns previously reported for the precentral gyrus. Thus, cerebellar nuclei are likely more involved than basal ganglia nuclei with the contributions of rostral M1 to manual dexterity. PMID:26254903
Park, Wanjoo; Jeong, Wookjin; Kwon, Gyu-Hyun; Kim, Yun-Hee; Kim, Laehyun
2013-06-01
This paper proposes a robotic hand rehabilitation device for grasp training. The device is designed for stroke patients to train and recover their hand grasp function in order to undertake activities of daily living (ADL). The device consists of a control unit, two small actuators, an infrared (IR) sensor, and pressure sensors in the grasp handle. The advantages of this device are that it is small in size, inexpensive, and available for use at home without specialist's supervision. In addition, a novel patient-driven strategy based on the patient's movement intention detected by the pressure sensors without bio-signals is introduced. Once the system detects a patient's movement intention, it triggers the robotic device to move the patient's hand to form the normal grasping behavior. This strategy may encourage stroke patients to participate in rehabilitation training to recover their hand grasp function and it may also enhance neural plasticity. A user study was conducted in order to investigate the usability, acceptability, satisfaction, and suggestions for improvement of the proposed device. The results of this survey included positive reviews from therapists and a stroke patient. In particular, therapists expected that the proposed patient-driven mode can motivate patients for their rehabilitation training and it can be effective to prevent a compensational strategy in active movements. It is expected that the proposed device will assist stroke patients in restoring their grasp function efficiently.
The origins of thalamic inputs to grasp zones in frontal cortex of macaque monkeys.
Gharbawie, Omar A; Stepniewska, Iwona; Kaas, Jon H
2016-07-01
The hand representation in primary motor cortex (M1) is instrumental to manual dexterity in primates. In Old World monkeys, rostral and caudal aspects of the hand representation are located in the precentral gyrus and the anterior bank of the central sulcus, respectively. We previously reported the organization of the cortico-cortical connections of the grasp zone in rostral M1. Here we describe the organization of thalamocortical connections that were labeled from the same tracer injections. Thalamocortical connections of a grasp zone in ventral premotor cortex (PMv) and the M1 orofacial representation are included for direct comparison. The M1 grasp zone was primarily connected with ventral lateral divisions of motor thalamus. The largest proportion of inputs originated in the posterior division (VLp) followed by the medial and the anterior divisions. Thalamic inputs to the M1 grasp zone originated in more lateral aspects of VLp as compared to the origins of thalamic inputs to the M1 orofacial representation. Inputs to M1 from thalamic divisions connected with cerebellum constituted three fold the density of inputs from divisions connected with basal ganglia, whereas the ratio of inputs was more balanced for the grasp zone in PMv. Privileged access of the cerebellothalamic pathway to the grasp zone in rostral M1 is consistent with the connection patterns previously reported for the precentral gyrus. Thus, cerebellar nuclei are likely more involved than basal ganglia nuclei with the contributions of rostral M1 to manual dexterity.
Fu, Qiushi; Santello, Marco
2018-01-01
The concept of postural synergies of the human hand has been shown to potentially reduce complexity in the neuromuscular control of grasping. By merging this concept with soft robotics approaches, a multi degrees of freedom soft-synergy prosthetic hand [SoftHand-Pro (SHP)] was created. The mechanical innovation of the SHP enables adaptive and robust functional grasps with simple and intuitive myoelectric control from only two surface electromyogram (sEMG) channels. However, the current myoelectric controller has very limited capability for fine control of grasp forces. We addressed this challenge by designing a hybrid-gain myoelectric controller that switches control gains based on the sensorimotor state of the SHP. This controller was tested against a conventional single-gain (SG) controller, as well as against native hand in able-bodied subjects. We used the following tasks to evaluate the performance of grasp force control: (1) pick and place objects with different size, weight, and fragility levels using power or precision grasp and (2) squeezing objects with different stiffness. Sensory feedback of the grasp forces was provided to the user through a non-invasive, mechanotactile haptic feedback device mounted on the upper arm. We demonstrated that the novel hybrid controller enabled superior task completion speed and fine force control over SG controller in object pick-and-place tasks. We also found that the performance of the hybrid controller qualitatively agrees with the performance of native human hands. PMID:29375360
General MoM Solutions for Large Arrays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fasenfest, B; Capolino, F; Wilton, D R
2003-07-22
This paper focuses on a numerical procedure that addresses the difficulties of dealing with large, finite arrays while preserving the generality and robustness of full-wave methods. We present a fast method based on approximating interactions between sufficiently separated array elements via a relatively coarse interpolation of the Green's function on a uniform grid commensurate with the array's periodicity. The interaction between the basis and testing functions is reduced to a three-stage process. The first stage is a projection of standard (e.g., RWG) subdomain bases onto a set of interpolation functions that interpolate the Green's function on the array face. Thismore » projection, which is used in a matrix/vector product for each array cell in an iterative solution process, need only be carried out once for a single cell and results in a low-rank matrix. An intermediate stage matrix/vector product computation involving the uniformly sampled Green's function is of convolutional form in the lateral (transverse) directions so that a 2D FFT may be used. The final stage is a third matrix/vector product computation involving a matrix resulting from projecting testing functions onto the Green's function interpolation functions; the low-rank matrix is either identical to (using Galerkin's method) or similar to that for the bases projection. An effective MoM solution scheme is developed for large arrays using a modification of the AIM (Adaptive Integral Method) method. The method permits the analysis of arrays with arbitrary contours and nonplanar elements. Both fill and solve times within the MoM method are improved with respect to more standard MoM solvers.« less
Performance, size, mass, and cost estimates for projected 1kW EOL Si, InP, and GaAs arrays
NASA Technical Reports Server (NTRS)
Slifer, Luther W., Jr.
1991-01-01
One method of evaluating the potential of emerging solar cell and array technologies is to compare their projected capabilities in space flight applications to those of established Si solar cells and arrays. Such an application-oriented comparison provides an integrated view of the elemental comparisons of efficiency, radiation resistance, temperature sensitivity, size, mass, and cost in combination. In addition, the assumptions necessary to make the comparisons provide insights helpful toward determining necessary areas of development or evaluation. Finally, as developments and evaluations progress, the results can be used in more precisely defining the overall potential of the new technologies in comparison to existing technologies. The projected capabilities of Si, InP, and GaAs cells and arrays are compared.
ERIC Educational Resources Information Center
Stöckel, Tino; Hughes, Charmayne M. L.
2015-01-01
This experiment examined how multiple planning constraints affect grasp posture planning in 6- to 10-year-old children (n = 16 in each group) by manipulating the intended object end-orientation (left end-down, right end-down) and initial precision demands (standard, initial precision) of a bar transport task. Results indicated that grasp posture…
Changes in performance over time while learning to use a myoelectric prosthesis
2014-01-01
Background Training increases the functional use of an upper limb prosthesis, but little is known about how people learn to use their prosthesis. The aim of this study was to describe the changes in performance with an upper limb myoelectric prosthesis during practice. The results provide a basis to develop an evidence-based training program. Methods Thirty-one able-bodied participants took part in an experiment as well as thirty-one age- and gender-matched controls. Participants in the experimental condition, randomly assigned to one of four groups, practiced with a myoelectric simulator for five sessions in a two-weeks period. Group 1 practiced direct grasping, Group 2 practiced indirect grasping, Group 3 practiced fixating, and Group 4 practiced a combination of all three tasks. The Southampton Hand Assessment Procedure (SHAP) was assessed in a pretest, posttest, and two retention tests. Participants in the control condition performed SHAP two times, two weeks apart with no practice in between. Compressible objects were used in the grasping tasks. Changes in end-point kinematics, joint angles, and grip force control, the latter measured by magnitude of object compression, were examined. Results The experimental groups improved more on SHAP than the control group. Interestingly, the fixation group improved comparable to the other training groups on the SHAP. Improvement in global position of the prosthesis leveled off after three practice sessions, whereas learning to control grip force required more time. The indirect grasping group had the smallest object compression in the beginning and this did not change over time, whereas the direct grasping and the combination group had a decrease in compression over time. Moreover, the indirect grasping group had the smallest grasping time that did not vary over object rigidity, while for the other two groups the grasping time decreased with an increase in object rigidity. Conclusions A training program should spend more time on learning fine control aspects of the prosthetic hand during rehabilitation. Moreover, training should start with the indirect grasping task that has the best performance, which is probably due to the higher amount of useful information available from the sound hand. PMID:24568148
Multisession, noninvasive closed-loop neuroprosthetic control of grasping by upper limb amputees.
Agashe, H A; Paek, A Y; Contreras-Vidal, J L
2016-01-01
Upper limb amputation results in a severe reduction in the quality of life of affected individuals due to their inability to easily perform activities of daily living. Brain-machine interfaces (BMIs) that translate grasping intent from the brain's neural activity into prosthetic control may increase the level of natural control currently available in myoelectric prostheses. Current BMI techniques demonstrate accurate arm position and single degree-of-freedom grasp control but are invasive and require daily recalibration. In this study we tested if transradial amputees (A1 and A2) could control grasp preshaping in a prosthetic device using a noninvasive electroencephalography (EEG)-based closed-loop BMI system. Participants attempted to grasp presented objects by controlling two grasping synergies, in 12 sessions performed over 5 weeks. Prior to closed-loop control, the first six sessions included a decoder calibration phase using action observation by the participants; thereafter, the decoder was fixed to examine neuroprosthetic performance in the absence of decoder recalibration. Ability of participants to control the prosthetic was measured by the success rate of grasping; ie, the percentage of trials within a session in which presented objects were successfully grasped. Participant A1 maintained a steady success rate (63±3%) across sessions (significantly above chance [41±5%] for 11 sessions). Participant A2, who was under the influence of pharmacological treatment for depression, hormone imbalance, pain management (for phantom pain as well as shoulder joint inflammation), and drug dependence, achieved a success rate of 32±2% across sessions (significantly above chance [27±5%] in only two sessions). EEG signal quality was stable across sessions, but the decoders created during the first six sessions showed variation, indicating EEG features relevant to decoding at a smaller timescale (100ms) may not be stable. Overall, our results show that (a) an EEG-based BMI for grasping is a feasible strategy for further investigation of prosthetic control by amputees, and (b) factors that may affect brain activity such as medication need further examination to improve accuracy and stability of BMI performance. © 2016 Elsevier B.V. All rights reserved.
Automated Array Assembly, Phase 2. Low-cost Solar Array Project, Task 4
NASA Technical Reports Server (NTRS)
Lopez, M.
1978-01-01
Work was done to verify the technological readiness of a select process sequence with respect to satisfying the Low Cost Solar Array Project objectives of meeting the designated goals of $.50 per peak watt in 1986 (1975 dollars). The sequence examined consisted of: (1) 3 inches diameter as-sawn Czochralski grown 1:0:0 silicon, (2) texture etching, (3) ion implanting, (4) laser annealing, (5) screen printing of ohmic contacts and (6) sprayed anti-reflective coatings. High volume production projections were made on the selected process sequence. Automated processing and movement of hardware at high rates were conceptualized to satisfy the PROJECT's 500 MW/yr capability. A production plan was formulated with flow diagrams integrating the various processes in the cell fabrication sequence.
Chandarana, Hersh; Feng, Li; Ream, Justin; Wang, Annie; Babb, James S; Block, Kai Tobias; Sodickson, Daniel K; Otazo, Ricardo
2015-11-01
This study aimed to demonstrate feasibility of free-breathing radial acquisition with respiratory motion-resolved compressed sensing reconstruction [extra-dimensional golden-angle radial sparse parallel imaging (XD-GRASP)] for multiphase dynamic gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced liver imaging, and to compare image quality to compressed sensing reconstruction with respiratory motion-averaging (GRASP) and prior conventional breath-held Cartesian-sampled data sets [BH volume interpolated breath-hold examination (VIBE)] in same patients. In this Health Insurance Portability and Accountability Act-compliant prospective study, 16 subjects underwent free-breathing continuous radial acquisition during Gd-EOB-DTPA injection and had prior BH-VIBE available. Acquired data were reconstructed using motion-averaging GRASP approach in which consecutive 84 spokes were grouped in each contrast-enhanced phase for a temporal resolution of approximately 14 seconds. Additionally, respiratory motion-resolved reconstruction was performed from the same k-space data by sorting each contrast-enhanced phase into multiple respiratory motion states using compressed sensing algorithm named XD-GRASP, which exploits sparsity along both the contrast-enhancement and respiratory-state dimensions.Contrast-enhanced dynamic multiphase XD-GRASP, GRASP, and BH-VIBE images were anonymized, pooled together in a random order, and presented to 2 board-certified radiologists for independent evaluation of image quality, with higher score indicating more optimal examination. The XD-GRASP reconstructions had significantly (all P < 0.05) higher overall image quality scores compared to GRASP for early arterial (reader 1: 4.3 ± 0.6 vs 3.31 ± 0.6; reader 2: 3.81 ± 0.8 vs 3.38 ± 0.9) and late arterial (reader 1: 4.5 ± 0.6 vs 3.63 ± 0.6; reader 2: 3.56 ± 0.5 vs 2.88 ± 0.7) phases of enhancement for both readers. The XD-GRASP also had higher overall image quality score in portal venous phase, which was significant for reader 1 (4.44 ± 0.5 vs 3.75 ± 0.8; P = 0.002). In addition, the XD-GRASP had higher overall image quality score compared to BH-VIBE for early (reader 1: 4.3 ± 0.6 vs 3.88 ± 0.6; reader 2: 3.81 ± 0.8 vs 3.50 ± 1.0) and late (reader 1: 4.5 ± 0.6 vs 3.44 ± 0.6; reader 2: 3.56 ± 0.5 vs 2.94 ± 0.9) arterial phases. Free-breathing motion-resolved XD-GRASP reconstructions provide diagnostic high-quality multiphase images in patients undergoing Gd-EOB-DTPA-enhanced liver examination.
Improving Grasp Skills Using Schema Structured Learning
NASA Technical Reports Server (NTRS)
Platt, Robert; Grupen, ROderic A.; Fagg, Andrew H.
2006-01-01
Abstract In the control-based approach to robotics, complex behavior is created by sequencing and combining control primitives. While it is desirable for the robot to autonomously learn the correct control sequence, searching through the large number of potential solutions can be time consuming. This paper constrains this search to variations of a generalized solution encoded in a framework known as an action schema. A new algorithm, SCHEMA STRUCTURED LEARNING, is proposed that repeatedly executes variations of the generalized solution in search of instantiations that satisfy action schema objectives. This approach is tested in a grasping task where Dexter, the UMass humanoid robot, learns which reaching and grasping controllers maximize the probability of grasp success.
Modeling of transdermal drug delivery with a microneedle array
NASA Astrophysics Data System (ADS)
Lv, Y.-G.; Liu, J.; Gao, Y.-H.; Xu, B.
2006-11-01
Transdermal drug delivery is generally limited by the extraordinary barrier properties of the stratum corneum, the outer 10-15 µm layer of skin. A conventional needle inserted across this barrier and into deeper tissues could effectively deliver drugs. However, it would lead to infection and cause pain, thereby reducing patient compliance. In order to administer a frequent injection of insulin and other therapeutic agents more efficiently, integrated arrays with very short microneedles were recently proposed as very good candidates for painless injection or extraction. A variety of microneedle designs have thus been made available by employing the fabrication tools of the microelectronics industry and using materials such as silicon, metals, polymers and glass with feature sizes ranging from sub-micron to nanometers. At the same time, experiments were also made to test the capability of the microneedles to inject drugs into tissues. However, due to the difficulty encountered in measurement, a detailed understanding of the spatial and transient drug delivery process still remains unclear up to now. To better grasp the mechanisms involved, quantitative theoretical models were developed in this paper to simultaneously characterize the flow and drug transport, and numerical solutions were performed to predict the kinetics of dispersed drugs injected into the skin from a microneedle array. Calculations indicated that increasing the initial injection velocity and accelerating the blood circulation in skin tissue with high porosity are helpful to enhance the transdermal drug delivery. This study provides the first quantitative simulation of fluid injection through a microneedle array and drug species transport inside the skin. The modeling strategy can also possibly be extended to deal with a wider range of clinical issues such as targeted nanoparticle delivery for therapeutics or molecular imaging.
Hoogenraad, Casper C.; Popa, Ioana; Futai, Kensuke; Sanchez-Martinez, Emma; Wulf, Phebe S.; van Vlijmen, Thijs; Dortland, Bjorn R.; Oorschot, Viola; Govers, Roland; Monti, Maria; Heck, Albert J. R.; Sheng, Morgan; Klumperman, Judith; Rehmann, Holger; Jaarsma, Dick; Kapitein, Lukas C.; van der Sluijs, Peter
2010-01-01
The endosomal pathway in neuronal dendrites is essential for membrane receptor trafficking and proper synaptic function and plasticity. However, the molecular mechanisms that organize specific endocytic trafficking routes are poorly understood. Here, we identify GRIP-associated protein-1 (GRASP-1) as a neuron-specific effector of Rab4 and key component of the molecular machinery that coordinates recycling endosome maturation in dendrites. We show that GRASP-1 is necessary for AMPA receptor recycling, maintenance of spine morphology, and synaptic plasticity. At the molecular level, GRASP-1 segregates Rab4 from EEA1/Neep21/Rab5-positive early endosomal membranes and coordinates the coupling to Rab11-labelled recycling endosomes by interacting with the endosomal SNARE syntaxin 13. We propose that GRASP-1 connects early and late recycling endosomal compartments by forming a molecular bridge between Rab-specific membrane domains and the endosomal SNARE machinery. The data uncover a new mechanism to achieve specificity and directionality in neuronal membrane receptor trafficking. PMID:20098723
A hybrid system for upper limb movement restoration in quadriplegics.
Varoto, Renato; Barbarini, Elisa Signoreto; Cliquet, Alberto
2008-09-01
Generally, quadriplegic individuals have difficulties performing object manipulation. Toward satisfactory manipulation, reach and grasp movements must be performed with voluntary control, and for that, grasp force feedback is essential. A hybrid system aiming at partial upper limb sensory-motor restoration for quadriplegics was built. Such device is composed of an elbow dynamic orthosis that provides elbow flexion/extension (range was approximately from 20 degrees to 120 degrees , and average angular speed was approximately 15 degrees /s) with forearm support, a wrist static orthosis and neuromuscular electrical stimulation for grasping generation, and a glove with force sensors that allows grasping force feedback. The glove presents two user interface modes: visual by light emitting diodes or audio emitted by buzzer. Voice control of the entire system (elbow dynamic orthosis and electrical stimulator) is performed by the patient. The movements provided by the hybrid system, combined with the scapular and shoulder movements performed by the patient, can aid quadriplegic individuals in tasks that involve reach and grasp movements.
Chahl, J S
2014-01-20
This paper describes an application for arrays of narrow-field-of-view sensors with parallel optical axes. These devices exhibit some complementary characteristics with respect to conventional perspective projection or angular projection imaging devices. Conventional imaging devices measure rotational egomotion directly by measuring the angular velocity of the projected image. Translational egomotion cannot be measured directly by these devices because the induced image motion depends on the unknown range of the viewed object. On the other hand, a known translational motion generates image velocities which can be used to recover the ranges of objects and hence the three-dimensional (3D) structure of the environment. A new method is presented for computing egomotion and range using the properties of linear arrays of independent narrow-field-of-view optical sensors. An approximate parallel projection can be used to measure translational egomotion in terms of the velocity of the image. On the other hand, a known rotational motion of the paraxial sensor array generates image velocities, which can be used to recover the 3D structure of the environment. Results of tests of an experimental array confirm these properties.
Advanced Laboratory and Field Arrays (ALFA) OWC Phase 1 Test
Bret Bosma
2016-11-07
Data from Phase 1 testing of a single ALFA OWC device at the O.H. Hinsdale Wave Research Laboratory (HWRL) at Oregon State University in Fall of 2016. Contains two zip files of raw data, one of project data ("array"), and a diagram of the device with dimensions. A "readme" file in the project data archive under "Docs" helps to explains the project data.
ERIC Educational Resources Information Center
Holmes, Scott A.; Heath, Matthew
2013-01-01
An issue of continued debate in the visuomotor control literature surrounds whether a 2D object serves as a representative proxy for a 3D object in understanding the nature of the visual information supporting grasping control. In an effort to reconcile this issue, we examined the extent to which aperture profiles for grasping 2D and 3D objects…
Artificial tactile sensing in minimally invasive surgery - a new technical approach.
Schostek, Sebastian; Ho, Chi-Nghia; Kalanovic, Daniel; Schurr, Marc O
2006-01-01
The loss of tactile sensation is a commonly known drawback of minimally invasive surgery (MIS). Since the advent of MIS, research activities in providing tactile information to the surgeon are still ongoing, in order to improve patient safety and to extend the indications for MIS. We have designed a tactile sensor system comprising a tactile laparoscopic grasper for surgical palpation. For this purpose, we developed a novel tactile sensor technology which allows the manufacturing of an integrated sensor array within an acceptable price range. The array was integrated into the jaws of a 10mm laparoscopic grasper. The tactile data are transferred wirelessly via Bluetooth and are presented visually to the surgeon. The goal was to be able to obtain information about the shape and consistency of tissue structures by gently compressing the tissue between the jaws of the tactile instrument and thus to be able to recognize and assess anatomical or pathological structures, even if they are hidden in the tissue. With a prototype of the tactile sensor system we have conducted bench-tests as well as in-vitro and in-vivo experiments. The system proved feasibility in an experimental environment, it was easy to use, and the novel tactile sensor array was applicable for both palpation and grasping manoeuvres with forces of up to 60N. The tactile data turned out to be a useful supplement to the minimal amount of haptic feedback that is provided by current endoscopic instruments and the endoscopic image under certain conditions.
Yamashita, Yasunobu; Ueda, Kazuki; Kawaji, Yuki; Tamura, Takashi; Itonaga, Masahiro; Yoshida, Takeichi; Maeda, Hiroki; Magari, Hirohito; Maekita, Takao; Iguchi, Mikitaka; Tamai, Hideyuki; Ichinose, Masao; Kato, Jun
2016-07-15
Transpapillary forceps biopsy is an effective diagnostic technique in patients with biliary stricture. This prospective study aimed to determine the usefulness of the wire-grasping method as a new technique for forceps biopsy. Consecutive patients with biliary stricture or irregularities of the bile duct wall were randomly allocated to either the direct or wire-grasping method group. In the wiregrasping method, forceps in the duodenum grasps a guidewire placed into the bile duct beforehand, and then, the forceps are pushed through the papilla without endoscopic sphincterotomy. In the direct method, forceps are directly pushed into the bile duct alongside a guide-wire. The primary endpoint was the success rate of obtaining specimens suitable for adequate pathological examination. In total, 32 patients were enrolled, and 28 (14 in each group) were eligible for analysis. The success rate was significantly higher using the wire-grasping method than the direct method (100% vs 50%, p=0.016). Sensitivity and accuracy for the diagnosis of cancer were comparable in patients with the successful procurement of biopsy specimens between the two methods (91% vs 83% and 93% vs 86%, respectively). The wire-grasping method is useful for diagnosing patients with biliary stricture or irregularities of the bile duct wall.
Reliable vision-guided grasping
NASA Technical Reports Server (NTRS)
Nicewarner, Keith E.; Kelley, Robert B.
1992-01-01
Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.
Observation-based training for neuroprosthetic control of grasping by amputees.
Agashe, Harshavardhan A; Contreras-Vidal, Jose L
2014-01-01
Current brain-machine interfaces (BMIs) allow upper limb amputees to position robotic arms with a high degree of accuracy, but lack the ability to control hand pre-shaping for grasping different objects. We have previously shown that low frequency (0.1-1 Hz) time domain cortical activity recorded at the scalp via electroencephalography (EEG) encodes information about grasp pre-shaping. To transfer this technology to clinical populations such as amputees, the challenge lies in constructing BMI models in the absence of overt training hand movements. Here we show that it is possible to train BMI models using observed grasping movements performed by a robotic hand attached to amputees' residual limb. Three transradial amputees controlled the grasping motion of an attached robotic hand via their EEG, following the action-observation training phase. Over multiple sessions, subjects successfully grasped the presented object (a bottle or a credit card) in 53±16 % of trials, demonstrating the validity of the BMI models. Importantly, the validation of the BMI model was through closed-loop performance, which demonstrates generalization of the model to unseen data. These results suggest `mirror neuron system' properties captured by delta band EEG that allows neural representation for action observation to be used for action control in an EEG-based BMI system.
Whishaw, Ian Q; Faraji, Jamshid; Kuntz, Jessica R; Mirza Agha, Behroo; Metz, Gerlinde A S; Mohajerani, Majid H
2017-09-08
Mice are adept in the use of their hands for activities such as feeding, which has led to their use in investigations of the neural basis of skilled-movements. We describe the syntactic organization of pasta-eating and the structure of hand movements used for pasta manipulation by the head-fixed mouse. An ethogram of mice consuming pieces of spaghetti reveals that they eat in bite/chew bouts. A bout begins with pasta lifted to the mouth and then manipulated with hand movements into a preferred orientation for biting. Manipulation involves many hand release-reach movements, each with a similar structure. A hand is advanced from a digit closed and flexed (collect) position to a digit extended and open position (overgrasp) and then to a digit closed and flexed (grasp) position. Reach distance, hand shaping, and grasp patterns featuring precision grasps or whole hand grasps are related. To bite, mice display hand preference and asymmetric grasps; one hand (guide grasp) directs food into the mouth and the other stabilizes the pasta for biting. When chewing after biting, the hands hold the pasta in a symmetric resting position. Pasta-eating is organized and features structured hand movements and so lends itself to the neural investigation of skilled-movements.
Effects of object shape on the visual guidance of action.
Eloka, Owino; Franz, Volker H
2011-04-22
Little is known of how visual coding of the shape of an object affects grasping movements. We addressed this issue by investigating the influence of shape perturbations on grasping. Twenty-six participants grasped a disc or a bar that were chosen such that they could in principle be grasped with identical movements (i.e., relevant sizes were identical such that the final grips consisted of identical separations of the fingers and no parts of the objects constituted obstacles for the movement). Nevertheless, participants took object shape into account and grasped the bar with a larger maximum grip aperture and a different hand angle than the disc. In 20% of the trials, the object changed its shape from bar to disc or vice versa early or late during the movement. If there was enough time (early perturbations), grasps were often adapted in flight to the new shape. These results show that the motor system takes into account even small and seemingly irrelevant changes of object shape and adapts the movement in a fine-grained manner. Although this adaptation might seem computationally expensive, we presume that its benefits (e.g., a more comfortable and more accurate movement) outweigh the costs. Copyright © 2011 Elsevier Ltd. All rights reserved.
Advanced photovoltaic solar array - Design and performance
NASA Technical Reports Server (NTRS)
Kurland, Richard; Stella, Paul
1992-01-01
This paper reports on the development of an ultralightweight flexible blanket, flatpack, foldout solar array design that can provide 3- to 4-fold improvement on specific power performance of current rigid panel arrays and a factor of two improvement over a first-generation flexible blanket array developed as a forerunner to the Space Station Freedom array. To date a prototype wing has been built with a projected specific power performance of about 138 W/kg at beginning-of-life (BOL) and 93 W/kg end-of-life (EOL) at 12 kW (BOL) for a 10-year geosynchronous (GEO) mission. The prototype wing hardware has been subjected to a series of system-level tests to demonstrate design feasibility. The design of the array is summarized. The major trade studies that led to the selection of the baseline design are discussed. Key system-level and component-level testing are described. Array-level performance projections are presented as a function of existing and advanced solar array component technology for various mission applications.
Ream, Justin M; Doshi, Ankur; Lala, Shailee V; Kim, Sooah; Rusinek, Henry; Chandarana, Hersh
2015-06-01
The purpose of this article was to assess the feasibility of golden-angle radial acquisition with compress sensing reconstruction (Golden-angle RAdial Sparse Parallel [GRASP]) for acquiring high temporal resolution data for pharmacokinetic modeling while maintaining high image quality in patients with Crohn disease terminal ileitis. Fourteen patients with biopsy-proven Crohn terminal ileitis were scanned using both contrast-enhanced GRASP and Cartesian breath-hold (volume-interpolated breath-hold examination [VIBE]) acquisitions. GRASP data were reconstructed with 2.4-second temporal resolution and fitted to the generalized kinetic model using an individualized arterial input function to derive the volume transfer coefficient (K(trans)) and interstitial volume (v(e)). Reconstructions, including data from the entire GRASP acquisition and Cartesian VIBE acquisitions, were rated for image quality, artifact, and detection of typical Crohn ileitis features. Inflamed loops of ileum had significantly higher K(trans) (3.36 ± 2.49 vs 0.86 ± 0.49 min(-1), p < 0.005) and v(e) (0.53 ± 0.15 vs 0.20 ± 0.11, p < 0.005) compared with normal bowel loops. There were no significant differences between GRASP and Cartesian VIBE for overall image quality (p = 0.180) or detection of Crohn ileitis features, although streak artifact was worse with the GRASP acquisition (p = 0.001). High temporal resolution data for pharmacokinetic modeling and high spatial resolution data for morphologic image analysis can be achieved in the same acquisition using GRASP.
Young, Jesse W; Heard-Booth, Amber N
2016-09-01
Young primates have relatively large hands and feet for their body size, perhaps enhancing grasping ability. We test the hypothesis that selection for improved grasping ability is responsible for these scaling trends by examining the ontogeny of intrinsic hand and foot proportions in capuchin monkeys (Cebus albifrons and Sapajus apella). If selection for improved grasping ability is responsible for the observed patterns of hand and foot growth in primates, we predicted that fingers and toes would be longer early in life and proportionally decline with age. We measured the lengths of manual and pedal metapodials and phalanges in a mixed-longitudinal radiographic sample. Bone lengths were (a) converted into phalangeal indices (summed non-distal phalangeal length/metapodial length) to test for age-related changes in intrinsic proportions and (b) fit to Gompertz models of growth to test for differences in the dynamics of phalangeal versus metapodial growth. Manual and pedal phalangeal indices nearly universally decreased with age in capuchin monkeys. Growth curve analyses revealed that metapodials generally grew at a faster rate, and for a longer duration, than corresponding phalanges. Our findings are consistent with the hypothesis that primates are under selection for increased grasping ability early in life. Relatively long digits may be functionally adaptive for growing capuchins, permitting a more secure grasp on both caregivers and arboreal supports, as well as facilitating early foraging. Additional studies of primates and other mammals, as well as tests of grasping performance, are required to fully evaluate the adaptive significance of primate hand and foot growth. © 2016 Wiley Periodicals, Inc.
Goodenberger, Katherine E; Boyer, Doug M; Orr, Caley M; Jacobs, Rachel L; Femiani, John C; Patel, Biren A
2015-03-01
Primate evolutionary morphologists have argued that selection for life in a fine branch niche resulted in grasping specializations that are reflected in the hallucal metatarsal (Mt1) morphology of extant "prosimians", while a transition to use of relatively larger, horizontal substrates explains the apparent loss of such characters in anthropoids. Accordingly, these morphological characters-Mt1 torsion, peroneal process length and thickness, and physiological abduction angle-have been used to reconstruct grasping ability and locomotor mode in the earliest fossil primates. Although these characters are prominently featured in debates on the origin and subsequent radiation of Primates, questions remain about their functional significance. This study examines the relationship between these morphological characters of the Mt1 and a novel metric of pedal grasping ability for a large number of extant taxa in a phylogenetic framework. Results indicate greater Mt1 torsion in taxa that engage in hallucal grasping and in those that utilize relatively small substrates more frequently. This study provides evidence that Carpolestes simpsoni has a torsion value more similar to grasping primates than to any scandentian. The results also show that taxa that habitually grasp vertical substrates are distinguished from other taxa in having relatively longer peroneal processes. Furthermore, a longer peroneal process is also correlated with calcaneal elongation, a metric previously found to reflect leaping proclivity. A more refined understanding of the functional associations between Mt1 morphology and behavior in extant primates enhances the potential for using these morphological characters to comprehend primate (locomotor) evolution. © 2014 Wiley Periodicals, Inc.
The influence of grasping habits and object orientation on motor planning in children and adults.
Jovanovic, Bianca; Schwarzer, Gudrun
2017-12-01
We investigated the influence of habitual grasp strategies and object orientation on motor planning in 3-year-olds and 4- to 5-year-old children and adults. Participants were required to rotate different vertically oriented objects around 180°. Usually, adults perform this task by grasping objects with an awkward grip (thumb and index finger pointing downward) at the beginning of the movement, in order to finish it with a comfortable hand position. This pattern corresponds to the well-known end-state comfort effect (ESC) in grasp planning. The presented objects were associated with different habitual grasp orientations that either corresponded with the grasp direction required to reach end-state comfort (downward) or implied a contrary grasp orientation (upward). Additionally, they were presented either in their usual, canonical orientation (e.g., shovel with the blade oriented downward versus cup with its opening oriented upward) or upside down. As dependent variable we analyzed the number of grips conforming to the end-state comfort principle (ESC score) realized in each object type and orientation condition. The number of grips conforming to ESC strongly increased with age. In addition, the extent to which end-state comfort was considered was influenced by the actual orientation of the objects' functional parts. Thus, in all age-groups the ESC score was highest when the functional parts of the objects were oriented downward (shovel presented canonically with blade pointing downward, cup presented upside down) and corresponded to the hand orientation needed to realize ESC. © 2017 Wiley Periodicals, Inc.
3D Visual Data-Driven Spatiotemporal Deformations for Non-Rigid Object Grasping Using Robot Hands
Mateo, Carlos M.; Gil, Pablo; Torres, Fernando
2016-01-01
Sensing techniques are important for solving problems of uncertainty inherent to intelligent grasping tasks. The main goal here is to present a visual sensing system based on range imaging technology for robot manipulation of non-rigid objects. Our proposal provides a suitable visual perception system of complex grasping tasks to support a robot controller when other sensor systems, such as tactile and force, are not able to obtain useful data relevant to the grasping manipulation task. In particular, a new visual approach based on RGBD data was implemented to help a robot controller carry out intelligent manipulation tasks with flexible objects. The proposed method supervises the interaction between the grasped object and the robot hand in order to avoid poor contact between the fingertips and an object when there is neither force nor pressure data. This new approach is also used to measure changes to the shape of an object’s surfaces and so allows us to find deformations caused by inappropriate pressure being applied by the hand’s fingers. Test was carried out for grasping tasks involving several flexible household objects with a multi-fingered robot hand working in real time. Our approach generates pulses from the deformation detection method and sends an event message to the robot controller when surface deformation is detected. In comparison with other methods, the obtained results reveal that our visual pipeline does not use deformations models of objects and materials, as well as the approach works well both planar and 3D household objects in real time. In addition, our method does not depend on the pose of the robot hand because the location of the reference system is computed from a recognition process of a pattern located place at the robot forearm. The presented experiments demonstrate that the proposed method accomplishes a good monitoring of grasping task with several objects and different grasping configurations in indoor environments. PMID:27164102
On the Evolution of Handedness: Evidence for Feeding Biases
Flindall, Jason W.; Gonzalez, Claudia L. R.
2013-01-01
Many theories have been put forward to explain the origins of right-handedness in humans. Here we present evidence that this preference may stem in part from a right hand advantage in grasping for feeding. Thirteen participants were asked to reach-to-grasp food items of 3 different sizes: SMALL (Cheerios®), MEDIUM (Froot Loops®), and LARGE (Oatmeal Squares®). Participants used both their right- and left-hands in separate blocks (50 trials each, starting order counterbalanced) to grasp the items. After each grasp, participants either a) ate the food item, or b) placed it inside a bib worn beneath his/her chin (25 trials each, blocked design, counterbalanced). The conditions were designed such that the outward and inward movement trajectories were similar, differing only in the final step of placing it in the mouth or bib. Participants wore Plato liquid crystal goggles that blocked vision between trials. All trials were conducted in closed-loop with 5000 ms of vision. Hand kinematics were recorded by an Optotrak Certus, which tracked the position of three infrared diodes attached separately to the index finger, thumb, and wrist. We found a task (EAT/PLACE) by hand (LEFT/RIGHT) interaction on maximum grip aperture (MGA; the maximum distance between the index finger and thumb achieved during grasp pre-shaping). MGAs were smaller during right-handed movements, but only when grasping with intent to eat. Follow-up tests show that the RIGHT-HAND/EAT MGA was significantly smaller than all other hand/task conditions. Because smaller grip apertures are typically associated with greater precision, our results demonstrate a right-hand advantage for the grasp-to-eat movement. From an evolutionary perspective, early humans may have preferred the hand that could grasp food with more precision, thereby maximizing the likelihood of retrieval, consumption, and consequently, survival. PMID:24236078
Concatenation of Observed Grasp Phases with Observer’s Distal Movements: A Behavioural and TMS Study
De Stefani, Elisa; Innocenti, Alessandro; De Marco, Doriana; Gentilucci, Maurizio
2013-01-01
The present study aimed at determining how actions executed by two conspecifics can be coordinated with each other, or more specifically, how the observation of different phases of a reaching-grasping action is temporary related to the execution of a movement of the observer. Participants observed postures of initial finger opening, maximal finger aperture, and final finger closing of grasp after observation of an initial hand posture. Then, they opened or closed their right thumb and index finger (experiments 1, 2 and 3). Response times decreased, whereas acceleration and velocity of actual finger movements increased when observing the two late phases of grasp. In addition, the results ruled out the possibility that this effect was due to salience of the visual stimulus when the hand was close to the target and confirmed an effect of even hand postures in addition to hand apparent motion due to the succession of initial hand posture and grasp phase. In experiments 4 and 5, the observation of grasp phases modulated even foot movements and pronunciation of syllables. Finally, in experiment 6, transcranial magnetic stimulation applied to primary motor cortex 300 ms post-stimulus induced an increase in hand motor evoked potentials of opponens pollicis muscle when observing the two late phases of grasp. These data suggest that the observation of grasp phases induced simulation which was stronger during observation of finger closing. This produced shorter response times, greater acceleration and velocity of the successive movement. In general, our data suggest best concatenation between two movements (one observed and the other executed) when the observed (and simulated) movement was to be accomplished. The mechanism joining the observation of a conspecific’s action with our own movement may be precursor of social functions. It may be at the basis for interactions between conspecifics, and related to communication between individuals. PMID:24278395
Turton, A J; Cunningham, P; van Wijck, F; Smartt, Hjm; Rogers, C A; Sackley, C M; Jowett, S; Wolf, S L; Wheatley, K; van Vliet, P
2017-07-01
To determine feasibility of a randomised controlled trial (RCT) of home-based Reach-to-Grasp training after stroke. single-blind parallel group RCT. Residual arm deficit less than 12 months post-stroke. Reach-to-Grasp training in 14 one-hour therapist's visits over 6 weeks, plus one hour self-practice per day (total 56 hours). Usual care. Action Research Arm Test (ARAT), Wolf Motor Function Test (WMFT), pre-randomisation, 7, 12, 24 weeks post-randomisation. Forty-seven participants (Reach-to-Grasp=24, usual care=23) were randomised over 17 months. Reach-to-Grasp participants received a median (IQR) 14 (13,14) visits, and performed 157 (96,211) repetitions per visit; plus 30 minutes (22,45) self-practice per day. Usual care participants received 10.5 (5,14) therapist visits, comprising 38.6 (30,45) minutes of arm therapy with 16 (6,24) repetitions of functional tasks per visit. Median ARAT scores in the reach-to-grasp group were 8.5 (3.0,24.0) at baseline and 14.5 (3.5,26.0) at 24 weeks compared to median of 4 at both time points (IQR: baseline (3.0,14.0), 24 weeks (3.0,30.0)) in the usual-care group. Median WMFT tasks completed at baseline and 24 weeks were 6 (3.0,11.5) and 8.5 (4.5,13.5) respectively in the reach-to-grasp group and 4 (3.0,10.0), 6 (3.0,14.0) in the usual care group. Incidence of arm pain was similar between groups. The study was stopped before 11 patients reached the 24 weeks assessment. An RCT of home-based Reach-to-Grasp training after stroke is feasible and safe. With ARAT being our preferred measure it is estimated that 240 participants will be needed for a future two armed trial.
3D Visual Data-Driven Spatiotemporal Deformations for Non-Rigid Object Grasping Using Robot Hands.
Mateo, Carlos M; Gil, Pablo; Torres, Fernando
2016-05-05
Sensing techniques are important for solving problems of uncertainty inherent to intelligent grasping tasks. The main goal here is to present a visual sensing system based on range imaging technology for robot manipulation of non-rigid objects. Our proposal provides a suitable visual perception system of complex grasping tasks to support a robot controller when other sensor systems, such as tactile and force, are not able to obtain useful data relevant to the grasping manipulation task. In particular, a new visual approach based on RGBD data was implemented to help a robot controller carry out intelligent manipulation tasks with flexible objects. The proposed method supervises the interaction between the grasped object and the robot hand in order to avoid poor contact between the fingertips and an object when there is neither force nor pressure data. This new approach is also used to measure changes to the shape of an object's surfaces and so allows us to find deformations caused by inappropriate pressure being applied by the hand's fingers. Test was carried out for grasping tasks involving several flexible household objects with a multi-fingered robot hand working in real time. Our approach generates pulses from the deformation detection method and sends an event message to the robot controller when surface deformation is detected. In comparison with other methods, the obtained results reveal that our visual pipeline does not use deformations models of objects and materials, as well as the approach works well both planar and 3D household objects in real time. In addition, our method does not depend on the pose of the robot hand because the location of the reference system is computed from a recognition process of a pattern located place at the robot forearm. The presented experiments demonstrate that the proposed method accomplishes a good monitoring of grasping task with several objects and different grasping configurations in indoor environments.
Direct write of microlens array using digital projection photopolymerization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu Yi; Chen Shaochen
Microlens array is a key element in the field of information processing, optoelectronics, and integrated optics. Many existing fabrication processes remain expensive and complicated even though relatively low-cost replication processes have been developed. Here, we demonstrate the fabrication of microlens arrays through projection photopolymerization using a digital micromirror device (DMD) as a dynamic photomask. The DMD projects grayscale images, which are designed in a computer, onto a photocurable resin. The resin is then solidified with its thickness determined by a grayscale ultraviolet light and exposure time. Therefore, various geometries can be formed in a single-step, massively parallel fashion. We presentmore » microlens arrays made of acrylate-based polymer precursor. The physical and optical characteristics of the resulting lenses suggest that this fabrication technique is potentially suitable for applications in integrated optics.« less
The NASA Deep Space Network (DSN) Array
NASA Technical Reports Server (NTRS)
Gatti, Mark
2006-01-01
The DSN Array Project is currently working with Senior Management at both JPL and NASA to develop strategies towards starting a major implementation project. Several studies within NASA are concluding, all of which recommend that any future DSN capability include arraying of antennas to increase performance. Support of Deep Space, Lunar, and CEV (crewed exploration vehicle) missions is possible. High data rate and TDRSS formatting is being investigated. Any future DSN capacity must include Uplink. Current studies ongoing to investigate and develop technologies for uplink arraying; provides advantages in three ways: 1) N2 effect. EIRP grows as N2(-vs-N for a downlink array); 2) Improved architectural options (can separate uplink and downlink); and 3) Potential for more cost effective transmitters for fixed EIRP.
Inferring the Size of a Goal Object from an Actor's Grasping Movement in 6- and 9-Month-Old Infants
ERIC Educational Resources Information Center
Daum, Moritz M.; Vuori, Maria T.; Prinz, Wolfgang; Aschersleben, Gisa
2009-01-01
The present study applied a preferential looking paradigm to test whether 6- and 9-month old infants are able to infer the size of a goal object from an actor's grasping movement. The target object was a cup with the handle rotated either towards or away from the actor. In two experiments, infants saw the video of an actor's grasping movement…
Development and preliminary testing of an instrumented object for force analysis during grasping.
Romeo, R A; Cordella, F; Zollo, L; Formica, D; Saccomandi, P; Schena, E; Carpino, G; Davalli, A; Sacchetti, R; Guglielmelli, E
2015-01-01
This paper presents the design and realization of an instrumented object for force analysis during grasping. The object, with spherical shape, has been constructed with three contact areas in order to allow performing a tripod grasp. Force Sensing Resistor (FSR) sensors have been employed for normal force measurements, while an accelerometer has been used for slip detection. An electronic board for data acquisition has been embedded into the object, so that only the cables for power supply exit from it. Validation tests have been carried out for: (i) comparing the force measurements with a ground truth; (ii) assessing the capability of the accelerometer to detect slippage for different roughness values; (iii) evaluating object performance in grasp trials performed by a human subject.
Digital Mapping of Buried Pipelines with a Dual Array System
DOT National Transportation Integrated Search
2005-03-01
The project carried out under this agreement, which was informally called the "Dual Array Project" (the term we will use in this report), was part of the research efforts at the Office of Pipeline Safety at U.S. DOT, and was one of seven contracts aw...
NASA Technical Reports Server (NTRS)
1983-01-01
A photovoltaic Metallization Research forum, under the sponsorship of the Flat-Plate Solar Array Project consisted of five sessions, covering: (1) the current status of metallization systems, (2) system design, (3) thick-film metallization, (4) advanced techniques, and (5) future metallization challenges.
... infants; Tonic neck reflex; Galant reflex; Truncal incurvation; Rooting reflex; Parachute reflex; Grasp reflex ... up if both hands are grasping your fingers. ROOTING REFLEX This reflex occurs when the baby's cheek ...
Progress of the MAGDAS Project During 2013
NASA Astrophysics Data System (ADS)
Maeda, G.; Yoshikawa, A.; Abe, S.
2013-12-01
The magnetometer array of the MAGDAS Project is perhaps the largest magnetometer array in the world -- with 71 real time magnetometers deployed around the world. In this presentation we explain the latest status of this array and the latest data release policy. In addition, we describe various MAGDAS activities of this year, such as: (1) the ISWI and MAGDAS School in Africa, (2) the ISWI/MAGDAS presentation by the MAGDAS PI at Graz, Austria, and (3) the maintenance work done in the field for magnetometers.
Proceedings of the 16th Project Integration Meeting
NASA Technical Reports Server (NTRS)
Mcdonald, R. R.
1980-01-01
The principal achievement of the Low Cost Solar Array Project in 1980 was the attainment of $2.80/Wp Technical Readiness, and that processes and equipment now commercially available can make possible a deliverable product in 1982. A prototype array for intermediate load applications was demonstrated using frameless modules. It was proof tested to 40 lb/sq ft loading, and priced at $24/sq m, including array fabrication, module installation, shipping to the site and site installation for quantities of 20 MW.
Tang, Rixin; Whitwell, Robert L; Goodale, Melvyn A
2015-05-01
Goal-directed movements, such as reaching out to grasp an object, are necessarily constrained by the spatial properties of the target such as its size, shape, and position. For example, during a reach-to-grasp movement, the peak width of the aperture formed by the thumb and fingers in flight (peak grip aperture, PGA) is linearly related to the target's size. Suppressing vision throughout the movement (visual open loop) has a small though significant effect on this relationship. Visual open loop conditions also produce a large increase in the PGA compared to when vision is available throughout the movement (visual closed loop). Curiously, this differential effect of the availability of visual feedback is influenced by the presentation order: the difference in PGA between closed- and open-loop trials is smaller when these trials are intermixed (an effect we have called 'homogenization'). Thus, grasping movements are affected not only by the availability of visual feedback (closed loop or open loop) but also by what happened on the previous trial. It is not clear, however, whether this carry-over effect is mediated through motor (or sensorimotor) memory or through the interference of different task sets for closed-loop and open-loop feedback that determine when the movements are fully specified. We reasoned that sensorimotor memory, but not a task set for closed and open loop feedback, would be specific to the type of response. We tested this prediction in a condition in which pointing to targets was alternated with grasping those same targets. Critically, in this condition, when pointing was performed in open loop, grasping was always performed in closed loop (and vice versa). Despite the fact that closed- and open-loop trials were alternating in this condition, we found no evidence for homogenization of the PGA. Homogenization did occur, however, in a follow-up experiment in which grasping movements and visual feedback were alternated between the left and the right hand, indicating that sensorimotor (or motor) memory can operate both within and between hands when the response type is kept the same. In a final experiment, we ruled out the possibility that simply alternating the hand used to perform the grasp interferes with motor or sensorimotor memory. We did this by showing that when the hand was alternated within a block of exclusively closed- or open-loop trials, homogenization of the PGA did not occur. Taken together, the results suggest that (1) interference from simply switching between task sets for closed or open-loop feedback or from switching between the hands cannot account homogenization in the PGA and that (2) the programming and execution of grasps can borrow not only from grasping movements executed in the past by the same hand, but also from grasping movements executed with the other hand. Copyright © 2015 Elsevier B.V. All rights reserved.
e-GRASP: an integrated evolutionary and GRASP resource for exploring disease associations.
Karim, Sajjad; NourEldin, Hend Fakhri; Abusamra, Heba; Salem, Nada; Alhathli, Elham; Dudley, Joel; Sanderford, Max; Scheinfeldt, Laura B; Chaudhary, Adeel G; Al-Qahtani, Mohammed H; Kumar, Sudhir
2016-10-17
Genome-wide association studies (GWAS) have become a mainstay of biological research concerned with discovering genetic variation linked to phenotypic traits and diseases. Both discrete and continuous traits can be analyzed in GWAS to discover associations between single nucleotide polymorphisms (SNPs) and traits of interest. Associations are typically determined by estimating the significance of the statistical relationship between genetic loci and the given trait. However, the prioritization of bona fide, reproducible genetic associations from GWAS results remains a central challenge in identifying genomic loci underlying common complex diseases. Evolutionary-aware meta-analysis of the growing GWAS literature is one way to address this challenge and to advance from association to causation in the discovery of genotype-phenotype relationships. We have created an evolutionary GWAS resource to enable in-depth query and exploration of published GWAS results. This resource uses the publically available GWAS results annotated in the GRASP2 database. The GRASP2 database includes results from 2082 studies, 177 broad phenotype categories, and ~8.87 million SNP-phenotype associations. For each SNP in e-GRASP, we present information from the GRASP2 database for convenience as well as evolutionary information (e.g., rate and timespan). Users can, therefore, identify not only SNPs with highly significant phenotype-association P-values, but also SNPs that are highly replicated and/or occur at evolutionarily conserved sites that are likely to be functionally important. Additionally, we provide an evolutionary-adjusted SNP association ranking (E-rank) that uses cross-species evolutionary conservation scores and population allele frequencies to transform P-values in an effort to enhance the discovery of SNPs with a greater probability of biologically meaningful disease associations. By adding an evolutionary dimension to the GWAS results available in the GRASP2 database, our e-GRASP resource will enable a more effective exploration of SNPs not only by the statistical significance of trait associations, but also by the number of studies in which associations have been replicated, and the evolutionary context of the associated mutations. Therefore, e-GRASP will be a valuable resource for aiding researchers in the identification of bona fide, reproducible genetic associations from GWAS results. This resource is freely available at http://www.mypeg.info/egrasp .
Programming of left hand exploits task set but that of right hand depends on recent history.
Tang, Rixin; Zhu, Hong
2017-07-01
There are many differences between the left hand and the right hand. But it is not clear if there is a difference in programming between left hand and right hand when the hands perform the same movement. In current study, we carried out two experiments to investigate whether the programming of two hands was equivalent or they exploited different strategies. In the first experiment, participants were required to use one hand to grasp an object with visual feedback or to point to the center of one object without visual feedback on alternate trials, or to grasp an object without visual feedback and to point the center of one object with visual feedback on alternating trials. They then performed the tasks with the other hand. The result was that previous pointing task affected current grasping when it was performed by the left hand, but not the right hand. In experiment 2, we studied if the programming of the left (or right) hand would be affected by the pointing task performed on the previous trial not only by the same hand, but also by the right (or left) hand. Participants pointed and grasped the objects alternately with two hands. The result was similar with Experiment 1, i.e., left-hand grasping was affected by right-hand pointing, whereas right-hand grasping was immune from the interference from left hand. Taken together, the results suggest that when open- and closed-loop trials are interleaved, motor programming of grasping with the right hand was affected by the nature of the online feedback on the previous trial only if it was a grasping trial, suggesting that the trial-to-trial transfer depends on sensorimotor memory and not on task set. In contrast, motor programming of grasping with the left hand can use information about the nature of the online feedback on the previous trial to specify the parameters of the movement, even when the type of movement that occurred was quite different (i.e., pointing) and was performed with the right hand. This suggests that trial-to-trial transfer with the left hand depends on some sort of carry-over of task set for dealing with the availability of visual feedback.
Cognitive vision system for control of dexterous prosthetic hands: Experimental evaluation
2010-01-01
Background Dexterous prosthetic hands that were developed recently, such as SmartHand and i-LIMB, are highly sophisticated; they have individually controllable fingers and the thumb that is able to abduct/adduct. This flexibility allows implementation of many different grasping strategies, but also requires new control algorithms that can exploit the many degrees of freedom available. The current study presents and tests the operation of a new control method for dexterous prosthetic hands. Methods The central component of the proposed method is an autonomous controller comprising a vision system with rule-based reasoning mounted on a dexterous hand (CyberHand). The controller, termed cognitive vision system (CVS), mimics biological control and generates commands for prehension. The CVS was integrated into a hierarchical control structure: 1) the user triggers the system and controls the orientation of the hand; 2) a high-level controller automatically selects the grasp type and size; and 3) an embedded hand controller implements the selected grasp using closed-loop position/force control. The operation of the control system was tested in 13 healthy subjects who used Cyberhand, attached to the forearm, to grasp and transport 18 objects placed at two different distances. Results The system correctly estimated grasp type and size (nine commands in total) in about 84% of the trials. In an additional 6% of the trials, the grasp type and/or size were different from the optimal ones, but they were still good enough for the grasp to be successful. If the control task was simplified by decreasing the number of possible commands, the classification accuracy increased (e.g., 93% for guessing the grasp type only). Conclusions The original outcome of this research is a novel controller empowered by vision and reasoning and capable of high-level analysis (i.e., determining object properties) and autonomous decision making (i.e., selecting the grasp type and size). The automatic control eases the burden from the user and, as a result, the user can concentrate on what he/she does, not on how he/she should do it. The tests showed that the performance of the controller was satisfactory and that the users were able to operate the system with minimal prior training. PMID:20731834
Omedes, Jason; Schwarz, Andreas; Müller-Putz, Gernot R; Montesano, Luis
2018-05-01
This paper presents a hybrid BCI combining neural correlates of natural movements and interaction error-related potentials (ErrP) to perform a 3D reaching task. It focuses on the impact that design factors of such a hybrid BCI have on the ErrP signatures and in their classification. Approach. Users attempted to control a 3D virtual interface that simulated their own hand, to reach and grasp two different objects. Three factors of interest were modulated during the experimentation: (1) execution speed of the grasping, (2) type of grasping and (3) motor commands generated by motor imagery or real motion. Thirteen healthy subjects carried out the protocol. The peaks and latencies of the ErrP were analyzed for the different factors as well as the classification performance. Main results. ErrP are evoked for erroneous commands decoded from neural correlates of natural movements. The ANOVA analyses revealed that latency and magnitude of the most characteristic ErrP peaks were significantly influenced by the speed at which the grasping was executed, but not the type of grasp. This resulted in an greater accuracy of single-trial decoding of errors for fast movements (75.65%) compared to slow ones (68.99%). Significance. Invariance of ErrP to different type of grasping movements and mental strategies proves this type of hybrid interface to be useful for the design of out of the lab applications such as the operation/control of prosthesis. Factors such as the speed of the movements have to be carefully tuned in order to optimize the performance of the system. . © 2018 IOP Publishing Ltd.
Wood, Daniel K; Chouinard, Philippe A; Major, Alex J; Goodale, Melvyn A
2017-12-01
Most object-directed limb movements can be carried out with a comfortable grasp posture. However, the orientation of an object relative to our bodies can sometimes lead us to select an uncomfortable or awkward grasp posture due to limitations imposed by the biomechanics of the arm. In a series of experiments, we identified a network of cortical areas that are engaged during the selection of movement strategies. Neurologically intact participants and two brain-damaged patients with overlapping lesions in the right posterior superior parietal lobule (pSPL) performed a grasp posture selection task in which biomechanical constraints were the primary consideration for selecting an action. The task induced states of bistable actions whereby the same stimulus gave rise to categorically different grasp postures. In a behavioral experiment, the two patients displayed a large range of manual bistability with the contralesional hand, resulting in a higher incidence of awkward grasping postures. In neurologically intact participants, a separate functional magnetic resonance imaging (fMRI) experiment revealed activation of a parieto-frontal network, which included the posterior intraparietal sulcus (pIPS) along the banks of the pSPL that was parametrically modulated by the degree of bistability in grasp posture selection. Superimposing this activation over the patients' structural MRIs revealed that the pIPS/pSPL activation in the neurologically intact participants overlapped with lesioned cortical tissue in both patients; all other areas of activation overlapped with intact cortical tissue in the patients. These results provide converging evidence that the posterior parietal cortex plays a critical role in selecting biomechanically appropriate postures during reach-to-grasp behaviors. Copyright © 2016 Elsevier Ltd. All rights reserved.
Grasping convergent evolution in syngnathids: a unique tale of tails.
Neutens, C; Adriaens, D; Christiaens, J; De Kegel, B; Dierick, M; Boistel, R; Van Hoorebeke, L
2014-06-01
Seahorses and pipehorses both possess a prehensile tail, a unique characteristic among teleost fishes, allowing them to grasp and hold onto substrates such as sea grasses. Although studies have focused on tail grasping, the pattern of evolutionary transformations that made this possible is poorly understood. Recent phylogenetic studies show that the prehensile tail evolved independently in different syngnathid lineages, including seahorses, Haliichthys taeniophorus and several types of so-called pipehorses. This study explores the pattern that characterizes this convergent evolution towards a prehensile tail, by comparing the caudal musculoskeletal organization, as well as passive bending capacities in pipefish (representing the ancestral state), pipehorse, seahorse and H. taeniophorus. To study the complex musculoskeletal morphology, histological sectioning, μCT-scanning and phase contrast synchrotron scanning were combined with virtual 3D-reconstructions. Results suggest that the independent evolution towards tail grasping in syngnathids reflects at least two quite different strategies in which the ancestral condition of a heavy plated and rigid system became modified into a highly flexible one. Intermediate skeletal morphologies (between the ancestral condition and seahorses) could be found in the pygmy pipehorses and H. taeniophorus, which are phylogenetically closely affiliated with seahorses. This study suggests that the characteristic parallel myoseptal organization as already described in seahorse (compared with a conical organization in pipefish and pipehorse) may not be a necessity for grasping, but represents an apomorphy for seahorses, as this pattern is not found in other syngnathid species possessing a prehensile tail. One could suggest that the functionality of grasping evolved before the specialized, parallel myoseptal organization seen in seahorses. However, as the grasping system in pipehorses is a totally different one, this cannot be concluded from this study. © 2014 Anatomical Society.
Grasping convergent evolution in syngnathids: a unique tale of tails
Neutens, C; Adriaens, D; Christiaens, J; De Kegel, B; Dierick, M; Boistel, R; Van Hoorebeke, L
2014-01-01
Seahorses and pipehorses both possess a prehensile tail, a unique characteristic among teleost fishes, allowing them to grasp and hold onto substrates such as sea grasses. Although studies have focused on tail grasping, the pattern of evolutionary transformations that made this possible is poorly understood. Recent phylogenetic studies show that the prehensile tail evolved independently in different syngnathid lineages, including seahorses, Haliichthys taeniophorus and several types of so-called pipehorses. This study explores the pattern that characterizes this convergent evolution towards a prehensile tail, by comparing the caudal musculoskeletal organization, as well as passive bending capacities in pipefish (representing the ancestral state), pipehorse, seahorse and H. taeniophorus. To study the complex musculoskeletal morphology, histological sectioning, μCT-scanning and phase contrast synchrotron scanning were combined with virtual 3D-reconstructions. Results suggest that the independent evolution towards tail grasping in syngnathids reflects at least two quite different strategies in which the ancestral condition of a heavy plated and rigid system became modified into a highly flexible one. Intermediate skeletal morphologies (between the ancestral condition and seahorses) could be found in the pygmy pipehorses and H. taeniophorus, which are phylogenetically closely affiliated with seahorses. This study suggests that the characteristic parallel myoseptal organization as already described in seahorse (compared with a conical organization in pipefish and pipehorse) may not be a necessity for grasping, but represents an apomorphy for seahorses, as this pattern is not found in other syngnathid species possessing a prehensile tail. One could suggest that the functionality of grasping evolved before the specialized, parallel myoseptal organization seen in seahorses. However, as the grasping system in pipehorses is a totally different one, this cannot be concluded from this study. PMID:24697519
NASA Astrophysics Data System (ADS)
Sarason, C. P.; Hartzler, R.; Anderson, A.
2016-02-01
Educational literature has many stories describing the "aha" moment that teachers are privileged to observe: a student who suddenly grasps a concept (ding!), dives into an activity (whee!) or works tirelessly to complete a complicated project (wow!). Designing moments like these for students can be one of the great joys of teaching. Experiencing such a moment can have a lasting impact on student engagement and motivation, and is the underlying rationale for the importance of creating a wide array of outreach efforts, from field work to telepresence activities.During the spring of 2015, OceanGate Foundation and Seattle Central College partnered on a pilot program to design a program that had this kind of impact and created the Open The Oceans Challenge. Student teams responded to our Request for Proposal (RFP), which was centered around the exploration of a shipwreck in 150 meters of water just off the Seattle waterfront, the MT-6. Students spent a significant amount of time crafting their proposals and reported that they enjoyed the process of writing the proposal as a team. The two winning teams accompanied us on a series of submersible dives performed by OceanGate, Inc. and worked up the results afterward. In addition to researching the MT-6 wreck and documenting what they found, students were able to do basic observational research on the wreck, providing sonar and photographic data that will help form the basis of future expeditions to this site.We report on lessons learned from this pilot — the impact for the small set of students involved in this project was profound, but how can we expand the reach of such activities? Results from this experience suggest that providing a highly engaging topic and expedition may not be enough to inspire an "aha" moment that creates lasting engagement; the scaffolding and mentorship that surrounds a rich experience is also critical.
Cartier-Michaud, Amandine; Bailly, Anne-Laure; Betzi, Stéphane; Shi, Xiaoli; Lissitzky, Jean-Claude; Zarubica, Ana; Sergé, Arnauld; Roche, Philippe; Lugari, Adrien; Hamon, Véronique; Bardin, Florence; Derviaux, Carine; Lembo, Frédérique; Audebert, Stéphane; Marchetto, Sylvie; Durand, Bénédicte; Borg, Jean-Paul; Shi, Ning; Morelli, Xavier; Aurrand-Lions, Michel
2017-06-01
Spermatogenesis is a dynamic process that is regulated by adhesive interactions between germ and Sertoli cells. Germ cells express the Junctional Adhesion Molecule-C (JAM-C, encoded by Jam3), which localizes to germ/Sertoli cell contacts. JAM-C is involved in germ cell polarity and acrosome formation. Using a proteomic approach, we demonstrated that JAM-C interacted with the Golgi reassembly stacking protein of 55 kDa (GRASP55, encoded by Gorasp2) in developing germ cells. Generation and study of Gorasp2-/- mice revealed that knock-out mice suffered from spermatogenesis defects. Acrosome formation and polarized localization of JAM-C in spermatids were altered in Gorasp2-/- mice. In addition, Golgi morphology of spermatocytes was disturbed in Gorasp2-/- mice. Crystal structures of GRASP55 in complex with JAM-C or JAM-B revealed that GRASP55 interacted via PDZ-mediated interactions with JAMs and induced a conformational change in GRASP55 with respect of its free conformation. An in silico pharmacophore approach identified a chemical compound called Graspin that inhibited PDZ-mediated interactions of GRASP55 with JAMs. Treatment of mice with Graspin hampered the polarized localization of JAM-C in spermatids, induced the premature release of spermatids and affected the Golgi morphology of meiotic spermatocytes.
NASA Technical Reports Server (NTRS)
Rajulu, Sudhakar L.; Klute, Glenn K.
1993-01-01
Astronauts have the task of retrieving and deploying satellites and handling massive objects in a around the payload bay. Concerns were raised that manual handling of such massive objects might induce loads to the shuttle suits exceeding the design-certified loads. The Crew and Thermal Division of NASA JSC simulated the satellite handling tasks (Satellite Manload Tests 1 and 3) and determined the maximum possible load that a suited member could impart onto the suit. In addition, the tests revealed that the load to the suit by an astronaut could be calculated from the astronaut's maximum hand grasp breakaway strength. Thus, this study was conducted to document that hand grasp breakaway strengths of the astronauts who were scheduled to perform EVA during the upcoming missions. In addition, this study verified whether the SML 3 test results were sufficient for documenting the maximum possible load. An attempt was made to predict grasp strength from grip strength and hand anthropometry. Based on the results from this study, the SML 3 test results were deemed sufficient to document the maximum possible load on the suit. Finally, prediction of grasp strength from grip strength was not as accurate as expected. Hence, it was recommended that grasp strength be collected from the astronauts in order to obtain accurate load estimation.
Kinematic characteristics of tenodesis grasp in C6 quadriplegia.
Mateo, S; Revol, P; Fourtassi, M; Rossetti, Y; Collet, C; Rode, G
2013-02-01
Descriptive control case study. To analyze the kinematics of tenodesis grasp in participants with C6 quadriplegia and healthy control participants in a pointing task and two daily life tasks involving a whole hand grip (apple) or a lateral grip (floppy disk). France. Four complete participants with C6 quadriplegia were age matched with four healthy control participants. All participants were right-handed. The measured kinematic parameters were the movement time (MT), the peak velocity (PV), the time of PV (TPV) and the wrist angle in the sagittal plane at movement onset, at the TPV and at the movement end point. The participants with C6 quadriplegia had significantly longer MTs in both prehension tasks. No significant differences in TPV were found between the two groups. Unlike control participants, for both prehension tasks the wrist of participants with C6 quadriplegia was in a neutral position at movement onset, in flexion at the TPV, and in extension at the movement end point. Two main kinematic parameters characterize tenodesis grasp movements in C6 quadriplegics: wrist flexion during reaching and wrist extension during the grasping phase, and increased MT reflecting the time required to adjust the wrist's position to achieve the tenodesis grasp. These characteristics were observed for two different grips (whole hand and lateral grip). These results suggest sequential planning of reaching and tenodesis grasp, and should be taken into account for prehension rehabilitation in patients with quadriplegia.
Learning visuomotor transformations for gaze-control and grasping.
Hoffmann, Heiko; Schenck, Wolfram; Möller, Ralf
2005-08-01
For reaching to and grasping of an object, visual information about the object must be transformed into motor or postural commands for the arm and hand. In this paper, we present a robot model for visually guided reaching and grasping. The model mimics two alternative processing pathways for grasping, which are also likely to coexist in the human brain. The first pathway directly uses the retinal activation to encode the target position. In the second pathway, a saccade controller makes the eyes (cameras) focus on the target, and the gaze direction is used instead as positional input. For both pathways, an arm controller transforms information on the target's position and orientation into an arm posture suitable for grasping. For the training of the saccade controller, we suggest a novel staged learning method which does not require a teacher that provides the necessary motor commands. The arm controller uses unsupervised learning: it is based on a density model of the sensor and the motor data. Using this density, a mapping is achieved by completing a partially given sensorimotor pattern. The controller can cope with the ambiguity in having a set of redundant arm postures for a given target. The combined model of saccade and arm controller was able to fixate and grasp an elongated object with arbitrary orientation and at arbitrary position on a table in 94% of trials.
Advanced Photovoltaic Solar Array program status
NASA Technical Reports Server (NTRS)
Kurland, Richard M.; Stella, Paul M.
1989-01-01
The Advanced Photolvoltaic Solar Array (APSA) Program is discussed. The objective of the program is to demonstrate a producible array system by the end of this decade with a beginning-of-life (BOL) specific power of 130 W/kg at 10 kW as an intermediate milestone toward the ultimate goal of 300 W/kg at 25 kW by the year 2000. The near-term goal represents a significant improvement over existing rigid panel flight arrays (25 to 45 W/kg) and the first-generation flexible blanket NASA/OAST SAFE I array of the early 1980s, which was projected to provide about 60 W/kg BOL. The prototype wing hardware is in the last stages of fabrication and integration. The current status of the program is reported. The array configuration and key design details are shown. Projections are shown for future performance enhancements that may be expected through the use of advanced structural components and solar cells.
Ulloa, Antonio; Bullock, Daniel
2003-10-01
We developed a neural network model to simulate temporal coordination of human reaching and grasping under variable initial grip apertures and perturbations of object size and object location/orientation. The proposed model computes reach-grasp trajectories by continuously updating vector positioning commands. The model hypotheses are (1) hand/wrist transport, grip aperture, and hand orientation control modules are coupled by a gating signal that fosters synchronous completion of the three sub-goals. (2) Coupling from transport and orientation velocities to aperture control causes maximum grip apertures that scale with these velocities and exceed object size. (3) Part of the aperture trajectory is attributable to an aperture-reducing passive biomechanical effect that is stronger for larger apertures. (4) Discrepancies between internal representations of targets partially inhibit the gating signal, leading to movement time increases that compensate for perturbations. Simulations of the model replicate key features of human reach-grasp kinematics observed under three experimental protocols. Our results indicate that no precomputation of component movement times is necessary for online temporal coordination of the components of reaching and grasping.
Capacity of small groups of muscles to accomplish precision grasping tasks.
Towles, Joseph D; Valero-Cuevas, Francisco J; Hentz, Vincent R
2013-01-01
An understanding of the capacity or ability of various muscle groups to generate endpoint forces that enable grasping tasks could provide a stronger biomechanical basis for the design of reconstructive surgery or rehabilitation for the treatment of the paralyzed or paretic hand. We quantified two-dimensional endpoint force distributions for every combination of the muscles of the index finger, in cadaveric specimens, to understand the capability of muscle groups to produce endpoint forces that accomplish three common types of grasps-tripod, tip and lateral pinch-characterized by a representative level of Coulomb friction. We found that muscle groups of 4 or fewer muscles were capable of generating endpoint forces that enabled performance of each of the grasping tasks examined. We also found that flexor muscles were crucial to accomplish tripod pinch; intrinsic muscles, tip pinch; and the dorsal interosseus muscle, lateral pinch. The results of this study provide a basis for decision making in the design of reconstructive surgeries and rehabilitation approaches that attempt to restore the ability to perform grasping tasks with small groups of muscles.
Zaepffel, Manuel; Brochier, Thomas
2012-01-01
We performed electroencephalogram (EEG) recording in a precuing task to investigate the planning processes of reach-to-grasp movements in human. In this reaction time (RT) task, subjects had to reach, grasp, and pull an object as fast as possible after a visual GO signal. We manipulated two parameters: the hand shape for grasping (precision grip or side grip) and the force required to pull the object (high or low). Three seconds before the GO onset, a cue provided advance information about force, grip, both parameters, or no information at all. EEG data show that reach-to-grasp movements generate differences in the topographic distribution of the late Contingent Negative Variation (ICNV) amplitude between the 4 precuing conditions. Along with RT data, it confirms that two distinct functional networks are involved with different time courses in the planning of grip and force. Finally, we outline the composite nature of the lCNV that might reflect both high- and low-level planning processes. Copyright © 2011 Society for Psychophysiological Research.
Development of High-Fill-Factor Large-Aperture Micromirrors for Agile Optical Phased Arrays
2010-02-28
Final Project Report Contract/Grant Title: Development of High-Fill-Factor Large-Aperture Micromirrors for Agile Optical Phased Arrays...factor (HFF) micromirror array (MMA) has been proposed, fabricated and tested. Optical-phased-array (OPA) beam steering based on the HFF MMA has also...electrically tuned to multiple 2. 1. Background High-fill-factor (HFF) micromirror arrays (MMAs) can form optical phased arrays (OPAs) for laser beam
NASA Technical Reports Server (NTRS)
Phillips, M. J.
1986-01-01
Abstracts of final reports, or the latest quarterly or annual, of the Flat-Plate Solar Array (FSA) Project Contractor of Jet Propulsion Laboratory (JPL) in-house activities are presented. Also presented is a list of proceedings and publications, by author, of work connected with the project. The aim of the program has been to stimulate the development of technology that will enable the private sector to manufacture and widely use photovoltaic systems for the generation of electricity in residential, commercial, industrial, and Government applications at a cost per watt that is competitive with utility generated power. FSA Project activities have included the sponsoring of research and development efforts in silicon refinement processes, advanced silicon sheet growth techniques, higher efficiency solar cells, solar cell/module fabrication processes, encapsulation, module/array engineering and reliability, and economic analyses.
Flat-plate solar array progress and plans
NASA Technical Reports Server (NTRS)
Callaghan, W. T.
1984-01-01
The results of research into the technology of flat-plate solar arrays undertaken in the Flat-Plate Solar Array Project under the sponsorship of the U.S. Department of Energy are surveyed. Topics examined include Si refinement, ribbon-sheet substrate formation, module process sequences, environmental isolation, module engineering and testing, and photovoltaic-array economics.
Solar Arrays for Low-Irradiance Low-Temperature and High-Radiation Environments
NASA Technical Reports Server (NTRS)
Boca, Andreea (Principal Investigator); Stella, Paul; Kerestes, Christopher; Sharps, Paul
2017-01-01
This is the Base Period final report DRAFT for the JPL task 'Solar Arrays for Low-Irradiance Low-Temperature and High-Radiation Environments', under Task Plan 77-16518 TA # 21, for NASA's Extreme Environments Solar Power (EESP) project. This report covers the Base period of performance, 7/18/2016 through 5/2/2017.The goal of this project is to develop an ultra-high efficiency lightweight scalable solar array technology for low irradiance, low temperature and high-radiation (LILT/Rad) environments. The benefit this technology will bring to flight systems is a greater than 20 reduction in solar array surface area, and a six-fold reduction in solar array mass and volume. The EESP project objectives are summarized in the 'NRA Goal' column of Table 1. Throughout this report, low irradiance low temperature (LILT) refers to 5AU -125 C test conditions; beginning of life (BOL) refers to the cell state prior to radiation exposure; and end of life (EOL) refers to the test article condition after exposure to a radiation dose of 4e15 1MeV e(-)/cm(exp 2).
Imaging System With Confocally Self-Detecting Laser.
Webb, Robert H.; Rogomentich, Fran J.
1996-10-08
The invention relates to a confocal laser imaging system and method. The system includes a laser source, a beam splitter, focusing elements, and a photosensitive detector. The laser source projects a laser beam along a first optical path at an object to be imaged, and modulates the intensity of the projected laser beam in response to light reflected from the object. A beam splitter directs a portion of the projected laser beam onto a photodetector. The photodetector monitors the intensity of laser output. The laser source can be an electrically scannable array, with a lens or objective assembly for focusing light generated by the array onto the object of interest. As the array is energized, its laser beams scan over the object, and light reflected at each point is returned by the lens to the element of the array from which it originated. A single photosensitive detector element can generate an intensity-representative signal for all lasers of the array. The intensity-representative signal from the photosensitive detector can be processed to provide an image of the object of interest.
NASA Astrophysics Data System (ADS)
Pfefferkorn, T.; Oxynos, C.; Greff, P.; Gerlach, L.
2008-09-01
After the successful series of Eurostar 3000 and Spacebus 4000 satellites and due to the demand of satellite operators for even larger and more powerful satellites, ESA decided to co-fund the development of a new satellite platform which covers the market segment beyond the upper limits of both satellite families.The new satellite bus family Alphabus is developed in the frame of ARTES 8 project by a joint project team of ASTRIUM and TAS, whereas the solar array is developed by ASTRIUM GmbH.The main approaches in this design phase for the Alphabus solar array were to find a standardized and scaleable design to production and to use qualification heritage from former projects, especially Eurostar 3000, as far as possible. The main challenges for the solar array design and test philosophy were the usage of lateral deployment and related sequential deployment and the bus voltage of 102,5V and related ESD precautions.This paper provides an overview of the different configurations, their main design features and performance parameters. In addition it summarizes the development and verification approach and shows the actual qualification status.
Frey, Scott H.; Hansen, Marc; Marchal, Noah
2016-01-01
Evidence implicates ventral parieto-premotor cortices in representing the goal of grasping independent of the movements or effectors involved [Umilta, M. A., Escola, L., Intskirveli, I., Grammont, F., Rochat, M., Caruana, F., et al. When pliers become fingers in the monkey motor system. Proceedings of the National Academy of Sciences, U.S.A., 105, 2209–2213, 2008; Tunik, E., Frey, S. H., & Grafton, S. T. Virtual lesions of the anterior intraparietal area disrupt goal-dependent on-line adjustments of grasp. Nature Neuroscience, 8, 505–511, 2005]. Modern technologies that enable arbitrary causal relationships between hand movements and tool actions provide a strong test of this hypothesis. We capitalized on this unique opportunity by recording activity with fMRI during tasks in which healthy adults performed goal-directed reach and grasp actions manually or by depressing buttons to initiate these same behaviors in a remotely located robotic arm (arbitrary causal relationship). As shown previously [Binkofski, F., Dohle, C., Posse, S., Stephan, K. M., Hefter, H., Seitz, R. J., et al. Human anterior intraparietal area subserves prehension: A combined lesion and functional MRI activation study. Neurology, 50, 1253–1259, 1998], we detected greater activity in the vicinity of the anterior intraparietal sulcus (aIPS) during manual grasp versus reach. In contrast to prior studies involving tools controlled by nonarbitrarily related hand movements [Gallivan, J. P., McLean, D. A., Valyear, K. F., & Culham, J. C. Decoding the neural mechanisms of human tool use. Elife, 2, e00425, 2013; Jacobs, S., Danielmeier, C., & Frey, S. H. Human anterior intraparietal and ventral premotor cortices support representations of grasping with the hand or a novel tool. Journal of Cognitive Neuroscience, 22, 2594–2608, 2010], however, responses within the aIPS and premotor cortex exhibited no evidence of selectivity for grasp when participants employed the robot. Instead, these regions showed comparable increases in activity during both the reach and grasp conditions. Despite equivalent sensorimotor demands, the right cerebellar hemisphere displayed greater activity when participants initiated the robot’s actions versus when they pressed a button known to be nonfunctional and watched the very same actions undertaken autonomously. This supports the hypothesis that the cerebellum predicts the forthcoming sensory consequences of volitional actions [Blakemore, S. J., Frith, C. D., & Wolpert, D. M. The cerebellum is involved in predicting the sensory consequences of action. NeuroReport, 12, 1879–1884, 2001]. We conclude that grasp-selective responses in the human aIPS and premotor cortex depend on the existence of nonarbitrary causal relationships between hand movements and end-effector actions. PMID:25436672
Reliability of the Ego-Grasping Scale.
Lester, David
2012-04-01
Research using Knoblauch and Falconer's Ego-Grasping Scale is reviewed. Using a sample of 695 undergraduate students, the scale had moderate reliability (Cronbach alpha, odd-even numbered items, and test-retest), but a principal-components analysis with a varimax rotation identified five components, indicating heterogeneity in the content of the items. Lower Ego-Grasping scores appear to be associated with better psychological health. The scale has been translated and used with Korean, Kuwaiti, and Turkish students, indicating that the scale can be useful in cross-cultural studies.
NASA Technical Reports Server (NTRS)
Hodges, D. H.; Hopkins, A. S.; Kunz, D. L.; Hinnant, H. E.
1986-01-01
The General Rotorcraft Aeromechanical Stability Program (GRASP), which is a hybrid between finite element programs and spacecraft-oriented multibody programs, is described in terms of its design and capabilities. Numerical results from GRASP are presented and compared with the results from an existing, special-purpose coupled rotor/body aeromechanical stability program and with experimental data of Dowell and Traybar (1975 and 1977) for large deflections of an end-loaded cantilevered beam. The agreement is excellent in both cases.
NASA Technical Reports Server (NTRS)
Venkataraman, Subramanian T. (Editor); Iberall, Thea (Editor)
1990-01-01
Recent studies of human hand function and their implications for the design of robot hands are discussed in reviews and reports. Topics addressed include human grasp choice and robotic grasp analysis, opposition space and human prehension, coordination in normal and prosthetic reaching, and intelligent exploration by the human hand. Consideration is given to a task-oriented dextrous manipulation architecture, the control architecture for the Belgrade/USC hand, the analysis of multifingered grasping and manipulation, and tactile sensing for shape interpretation. Diagrams, graphs, and photographs are provided.
Whisker and Nose Tactile Sense Guide Rat Behavior in a Skilled Reaching Task
Parmiani, Pierantonio; Lucchetti, Cristina; Franchi, Gianfranco
2018-01-01
Skilled reaching is a complex movement in which a forelimb is extended to grasp food for eating. Video-recordings analysis of control rats enables us to distinguish several components of skilled reaching: Orient, approaching the front wall of the reaching box and poking the nose into the slot to locate the food pellet; Transport, advancing the forelimb through the slot to reach-grasp the pellet; and Withdrawal of the grasped food to eat. Although food location and skilled reaching is guided by olfaction, the importance of whisker/nose tactile sense in rats suggests that this too could play a role in reaching behavior. To test this hypothesis, we studied skilled reaching in rats trained in a single-pellet reaching task before and after bilateral whisker trimming and bilateral infraorbital nerve (ION) severing. During the task, bilaterally trimmed rats showed impaired Orient with respect to controls. Specifically, they detected the presence of the wall by hitting it with their nose (rather than their whiskers), and then located the slot through repetitive nose touches. The number of nose touches preceding poking was significantly higher in comparison to controls. On the other hand, macrovibrissae trimming resulted in no change in reaching/grasping or withdrawal components of skilled reaching. Bilaterally ION-severed rats, displayed a marked change in the structure of their skilled reaching. With respect to controls, in ION-severed rats: (a) approaches to the front wall were significantly reduced at 3–5 and 6–8 days; (b) nose pokes were significantly reduced at 3–5 days, and the slot was only located after many repetitive nose touches; (c) the reaching-grasping-retracting movement never appeared at 3–5 days; (d) explorative paw movements, equal to zero in controls, reached significance at 9–11 days; and (e) the restored reaching-grasping-retracting sequence was globally slower than in controls, but the success rate was the same. These findings strongly indicate that whisker trimming affected Orient, but not the reaching-grasping movement, while ION severing impaired both Orient (persistently) and reaching-grasping-retracting (transiently, for 1–2 weeks) components of skilled reaching in rats. PMID:29515377
Outlook for Detecting Gravitational Waves with Pulsars
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2016-04-01
Though the recent discovery of GW150914 is a thrilling success in the field of gravitational-wave astronomy, LIGO is only one tool the scientific community is using to hunt for these elusive signals. After 10 years of unsuccessful searching, how likely is it that pulsar-timing-array projects will make their own first detection soon?Frequency ranges for gravitational waves produced by different astrophysical sources. Pulsar timing arrays such as the EPTA and IPTA are used to detect low-frequency gravitational waves generated by the stochastic background and supermassive black hole binaries. [Christopher Moore, Robert Cole and Christopher Berry]Supermassive BackgroundGround-based laser interferometers like LIGO are ideal for probing ripples in space-time caused by the merger of stellar-mass black holes; these mergers cause chirps in the frequency range of tens to thousands of hertz. But how do we pick up the extremely low-frequency, nanohertz background signal caused by the orbits of pairs of supermassive black holes? For that, we need pulsar timing arrays.Pulsar timing arrays are sets of pulsars whose signals are analyzed to look for correlations in the pulse arrival time. As the space-time between us and a pulsar is stretched and then compressed by a passing gravitational wave, the pulsars pulses should arrive a little late and then a little early. Comparing these timing residuals in an array of pulsars could theoretically allow for the detection of the gravitational waves causing them.Globally, there are currently four pulsar timing array projects actively searching for this signal, with a fifth planned for the future. Now a team of scientists led by Stephen Taylor (NASA-JPL/Caltech) has estimated the likelihood that these projects will successfully detect gravitational waves in the future.Probability for SuccessExpected detection probability of the gravitational-wave background as a function of observing time, for five different pulsar timing arrays. Optimistic and conservative assumptions are made for merger rates (blue and red lines, respectively) and environmental conditions (solid and dashed lines, respectively). [Taylor et al. 2016]Taylor and collaborators statistically analyzed the detection probability for each of the projects as a function of their observing time, based on the projects estimated sensitivities and both conservative and optimistic assumptions about merger rates and environmental influences.First the bad news: based on the authors estimates, small arrays which contain only a few pulsars that each have minimal timing noise will not be likely to detect gravitational waves within the next two decades. These arrays are more useful for setting upper limits on the amplitude of the gravitational-wave background.On the other hand, large pulsar timing arrays have far more promising detection probabilities. These include the Parkes Pulsar Timing Array, the European Pulsar Timing Array, andNANOGrav which each targettens ofpulsars,withthe intent toadd more in the future as well as the International Pulsar Timing Array, which combines the efforts of all three of these projects. There is an 80% chance that, within the next decade, these projects will successfully detect the gravitational-wave background created by orbiting supermassive black holes.Based on this study, the outlook for these large arrays remains optimistic even in non-ideal conditions (such as if supermassive-black-hole merger rates are lower than we thought). So, though we may still have to wait a few years, the possibility of probing an otherwise inaccessible range of frequencies continues to make pulsar timing arrays a promising avenue of study for gravitational waves.CitationS. R. Taylor et al 2016 ApJ 819 L6. doi:10.3847/2041-8205/819/1/L6
Head Mounted Display with a Roof Mirror Array Fold
NASA Technical Reports Server (NTRS)
Olczak, Eugene (Inventor)
2014-01-01
The present invention includes a head mounted display (HMD) worn by a user. The HMD includes a display projecting an image through an optical lens. The HMD also includes a one-dimensional retro reflective array receiving the image through the optical lens at a first angle with respect to the display and deflecting the image at a second angle different than the first angle with respect to the display. The one-dimensional retro reflective array reflects the image in order to project the image onto an eye of the user.
Grasping objects by their handles: a necessary interaction between cognition and action
NASA Technical Reports Server (NTRS)
Creem, S. H.; Proffitt, D. R.; Kaiser, M. K. (Principal Investigator)
2001-01-01
Research has illustrated dissociations between "cognitive" and "action" systems, suggesting that different representations may underlie phenomenal experience and visuomotor behavior. However, these systems also interact. The present studies show a necessary interaction when semantic processing of an object is required for an appropriate action. Experiment 1 demonstrated that a semantic task interfered with grasping objects appropriately by their handles, but a visuospatial task did not. Experiment 2 assessed performance on a visuomotor task that had no semantic component and showed a reversal of the effects of the concurrent tasks. In Experiment 3, variations on concurrent word tasks suggested that retrieval of semantic information was necessary for appropriate grasping. In all, without semantic processing, the visuomotor system can direct the effective grasp of an object, but not in a manner that is appropriate for its use.
Comparison of force and tactile feedback for grasp force control in telemanipulation
NASA Technical Reports Server (NTRS)
Wiker, Steven F.; Duffie, Neil A.; Yen, Thomas Y.; Gale, Karen L.
1991-01-01
The comparative efficacy of using direct force feedback or a simple vibrotactile display to convey changes in the intensity of remote grasp force relayed from a robotic end effector is examined. The findings show that a simple vibrotactile cue, in the absence of direct force feedback, is effective in signaling abrupt changes in remote grasp force regardless of magnitude, and when changes in force are not too slow or protracted in nature (i.e., ramp time less than 2 s). In cases where the operator must dynamically tract and respond to slow but large variations in grasp force, the comparatively crude vibrotactile display would prove helpful; but would not be as effective as that of a direct contact force display. Immediate applications and utility of current generation and near-term prototype tactile displays are discussed.
Impaired anticipatory control of grasp during obstacle crossing in Parkinson's disease.
McIsaac, Tara L; Diermayr, Gudrun; Albert, Frederic
2012-05-16
During self-paced walking, people with Parkinson's disease maintain anticipatory control during object grasping. However, common functional tasks often include carrying an object while changing step patterns mid-path and maneuvering over obstacles, increasing task complexity and attentional demands. Thus, the present study investigated the effect of Parkinson's disease on the modulation of grasping force changes as a function of gait-related inertial forces. Subjects with Parkinson's disease maintained the ability to scale and to couple over time their grip and inertial forces while walking at irregular step lengths, but were unable to maintain the temporal coupling of grasping forces compared to controls during obstacle crossing. We suggest that this deterioration in anticipatory control is associated with the increased demands of task complexity and attention during obstacle crossing. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Graphical representation of robot grasping quality measures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varma, V.; Tasch, U.
1993-11-01
When an object is held by a multi-fingered hand, the values of the contact forces can be multivalued. An objective function, when used in conjunction with the frictional and geometric constraints of the grasp, can however, give a unique set of finger force values. The selection of the objective function in determining the finger forces is dependent on the type of grasp required, the material properties of the object, and the limitations of the robot fingers. In this paper several optimization functions are studied and their merits highlighted. A graphical representation of the finger force values and the objective functionmore » is introduced that enable one in selecting and comparing various grasping configurations. The impending motion of the object at different torque and finger force values are determined by observing the normalized coefficient of friction plots.« less
E-GRASP/Eratosthenes: GRGS numerical simulations and millimetric TRF realization
NASA Astrophysics Data System (ADS)
Pollet, A.; Coulot, D.; Biancale, R.; Mandea, M.
2017-12-01
To accurately measuring and understanding changes in sea level, ice sheets and other elements of the dynamic Earth system, a stable Terrestrial Reference Frame (TRF) is needed. To reach the goals for the TRF realization of 1 mm accuracy and 0.1 mm/year stability (GGOS, Meeting the Requirements of a Global Society on a Changing Planet in 2020, Plag and Pearlman, 2009), The European - Geodetic Reference Antenna in Space (E-GRASP) has been recently proposed to the ESA EE9 call. This space mission is designed to build an enduring and stable TRF, by carrying very precise sensor systems for all the key geodetic techniques used to define and monitor the TRF (DORIS, GNSS, SLR and VLBI).In this study, we present the numerical simulations carried out by the French Groupe de Recherche en Géodésie Spatiale (GRGS). We simulated the measurements of the four geodetic techniques (DORIS and SLR measurements to E-GRASP, VLBI interferometric measurements on E-GRASP and GPS measurements from ground stations and from E-GRASP) over five years. Next, we have evaluated the expected exactitude and stability of the TRF provided by the processing of these measurements. In addition, we show the expected impact of the on-board instrument calibration on the TRF. Finally, we simulated the measurements of the two LAGEOS and four DORIS satellites, quasars for VLBI and we computed two multi-technique combinations, one with E-GRASP measurements and one without, to evaluate the contribution of this satellite to a combination.
Makuuchi, Michiru; Someya, Yoshiaki; Ogawa, Seiji; Takayama, Yoshihiro
2011-01-01
In visually guided grasping, possible hand shapes are computed from the geometrical features of the object, while prior knowledge about the object and the goal of the action influence both the computation and the selection of the hand shape. We investigated the system dynamics of the human brain for the pantomiming of grasping with two aspects accentuated. One is object recognition, with the use of objects for daily use. The subjects mimed grasping movements appropriate for an object presented in a photograph either by precision or power grip. The other is the selection of grip hand shape. We manipulated the selection demands for the grip hand shape by having the subjects use the same or different grip type in the second presentation of the identical object. Effective connectivity analysis revealed that the increased selection demands enhance the interaction between the anterior intraparietal sulcus (AIP) and posterior inferior temporal gyrus (pITG), and drive the converging causal influences from the AIP, pITG, and dorsolateral prefrontal cortex to the ventral premotor area (PMv). These results suggest that the dorsal and ventral visual areas interact in the pantomiming of grasping, while the PMv integrates the neural information of different regions to select the hand posture. The present study proposes system dynamics in visually guided movement toward meaningful objects, but further research is needed to examine if the same dynamics is found also in real grasping. PMID:21739528
Brain Function Overlaps When People Observe Emblems, Speech, and Grasping
Andric, Michael; Solodkin, Ana; Buccino, Giovanni; Goldin-Meadow, Susan; Rizzolatti, Giacomo; Small, Steven L.
2013-01-01
A hand grasping a cup or gesturing ‘thumbs-up’, while both manual actions, have different purposes and effects. Grasping directly affects the cup, whereas gesturing ‘thumbs-up’ has an effect through an implied verbal (symbolic) meaning. Because grasping and emblematic gestures (‘emblems’) are both goal-oriented hand actions, we pursued the hypothesis that observing each should evoke similar activity in neural regions implicated in processing goal-oriented hand actions. However, because emblems express symbolic meaning, observing them should also evoke activity in regions implicated in interpreting meaning, which is most commonly expressed in language. Using fMRI to test this hypothesis, we had participants watch videos of an actor performing emblems, speaking utterances matched in meaning to the emblems, and grasping objects. Our results show that lateral temporal and inferior frontal regions respond to symbolic meaning, even when it is expressed by a single hand action. In particular, we found that left inferior frontal and right lateral temporal regions are strongly engaged when people observe either emblems or speech. In contrast, we also replicate and extend previous work that implicates parietal and premotor responses in observing goal-oriented hand actions. For hand actions, we found that bilateral parietal and premotor regions are strongly engaged when people observe either emblems or grasping. These findings thus characterize converging brain responses to shared features (e.g., symbolic or manual), despite their encoding and presentation in different stimulus modalities. PMID:23583968
The effects of shape crowding on grasping.
Chen, Juan; Jayawardena, Sanasi; Goodale, Melvyn Alan
2015-03-10
Crowding refers to the deleterious effect of nearby objects on the identification of a target in the peripheral visual field. A recent study (Chen, Sperandio, & Goodale, 2015) showed that when a three-dimensional (3D) disk was crowded by disks of different sizes, participants could scale their grip aperture to the size of the target, even when they could not perceive its size. It is still unclear, however, whether or not grasping can also escape to some degree the crowding of other object features, such as shape. To test this, we presented 3D rectangular blocks in isolation or crowded by other blocks in the periphery. The target and flanking blocks had the same surface area but different dimensions. Participants were required either to grasp the target block across its width or to estimate its width. We found that, consistent with what we observed earlier with size, participants can also scale their grasp to the width of the target block even when they could not perceive its width. To further explore whether or not the effect of crowding on grasping depends on how proficient people are with their right hand, we had right-handed participants perform the same test but with their left hand. We found that left-hand grasping did not escape the crowding effect on shape perception at all. Taken together, our results suggest that people can also use invisible shape information to guide actions and that this ability depends on the proficiency of the action. © 2015 ARVO.
Multimodal Encoding of Goal-Directed Actions in Monkey Ventral Premotor Grasping Neurons.
Bruni, Stefania; Giorgetti, Valentina; Fogassi, Leonardo; Bonini, Luca
2017-01-01
Visuo-motor neurons of the ventral premotor area F5 encode "pragmatic" representations of object in terms of the potential motor acts (e.g., precision grip) afforded by it. Likewise, objects with identical pragmatic features (e.g., small spheres) but different behavioral value (e.g., edible or inedible) convey different "semantic" information and thus afford different goal-directed behaviors (e.g., grasp-to-eat or grasp-to-place). However, whether F5 neurons can extract distinct behavioral affordances from objects with similar pragmatic features is unknown. We recorded 134 F5 visuo-motor neurons in 2 macaques during a contextually cued go/no-go task in which the monkey grasped, or refrained from grasping, a previously presented edible or inedible target to eat it or placing it, respectively. Sixty-nine visuo-motor neurons showed motor selectivity for the target (35 food and 34 object), and about half of them (N = 35) exhibited congruent visual preference. Interestingly, when the monkey grasped in complete darkness and could identify the target only based on haptic feedback, visuo-motor neurons lost their precontact selectivity, but most of them (80%) showed it again 60 ms after hand-target contact. These findings suggest that F5 neurons possess a multimodal access to semantic information on objects, which are transformed into motor representations of the potential goal-directed actions afforded by them. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Wiker, Steven F.; Hershkowitz, Elaine; Zik, John
1989-01-01
The following question is addressed: How much force should operators exert, or experience, when operating a telemanipulator master-controller for sustained periods without encountering significant fatigue and discomfort, and without loss of stability in psychometric perception of force. The need to minimize exertion demands to avoid fatigue is diametrically opposed by the need to present a wide range of force stimuli to enhance perception of applied or reflected forces. For 104 minutes subjects repetitiously performed a series of 15 s isometric pinch grasps; controlled at 5, 15, and 25 percent of their maximum voluntary strength. Cyclic pinch grasps were separated by rest intervals of 7.5 and 15 s. Upon completion of every 10 minute period, subjects interrupted grasping activities to gage the intensity of fatigue and discomfort in the hand and forearm using a cross-modal matching technique. A series of psychometric tests were then conducted to determine accuracy and stability in the subject's perception of force experienced. Results showed that onset of sensations of discomfort and fatigue were dependent upon the magnitude of grasp force, work/rest ratio, and progression of task. Declines in force magnitude estimation slopes, indicating a reduction in force perception sensitivity, occurred with increased grasp force when work/rest ratios were greater than 1.0. Specific recommendations for avoiding discomfort and shifts in force perception, by limiting pinch grasp force required for master-controller operation and range of force reflection or work/rest ratios, are provided.
Toward autonomous avian-inspired grasping for micro aerial vehicles.
Thomas, Justin; Loianno, Giuseppe; Polin, Joseph; Sreenath, Koushil; Kumar, Vijay
2014-06-01
Micro aerial vehicles, particularly quadrotors, have been used in a wide range of applications. However, the literature on aerial manipulation and grasping is limited and the work is based on quasi-static models. In this paper, we draw inspiration from agile, fast-moving birds such as raptors, that are able to capture moving prey on the ground or in water, and develop similar capabilities for quadrotors. We address dynamic grasping, an approach to prehensile grasping in which the dynamics of the robot and its gripper are significant and must be explicitly modeled and controlled for successful execution. Dynamic grasping is relevant for fast pick-and-place operations, transportation and delivery of objects, and placing or retrieving sensors. We show how this capability can be realized (a) using a motion capture system and (b) without external sensors relying only on onboard sensors. In both cases we describe the dynamic model, and trajectory planning and control algorithms. In particular, we present a methodology for flying and grasping a cylindrical object using feedback from a monocular camera and an inertial measurement unit onboard the aerial robot. This is accomplished by mapping the dynamics of the quadrotor to a level virtual image plane, which in turn enables dynamically-feasible trajectory planning for image features in the image space, and a vision-based controller with guaranteed convergence properties. We also present experimental results obtained with a quadrotor equipped with an articulated gripper to illustrate both approaches.
Westlake, Kelly P; Johnson, Brian P; Creath, Robert A; Neff, Rachel M; Rogers, Mark W
2016-03-01
Reactive balance recovery strategies following an unexpected loss of balance are crucial to the prevention of falls, head trauma and other major injuries in older adults. While a longstanding focus has been on understanding lower limb recovery responses, the upper limbs also play a critical role. However, when a fall occurs, little is known about the role of memory and attention shifting on the reach to grasp recovery strategy and what factors determine the speed and precision of this response beyond simple reaction time. The objective of this study was to compare response time and accuracy of a stabilizing grasp following a balance perturbation in older adult fallers compared to non-fallers and younger adults while loading the processing demands of non-spatial, verbal working memory. Working memory was engaged with a progressively challenging verb-generation task that was interrupted by an unexpected sideways platform perturbation and a pre-instructed reach to grasp response. Results revealed that the older adults, particularly those at high fall risk, demonstrated significantly increased movement time to handrail contact and grasping errors during conditions in which non-spatial memory was actively engaged. These findings provide preliminary evidence of the cognitive deficit in attention shifting away from an ongoing working memory task that underlies delayed and inaccurate protective reach to grasp responses in older adult fallers. Copyright © 2016 Elsevier B.V. All rights reserved.
Grasp movement decoding from premotor and parietal cortex.
Townsend, Benjamin R; Subasi, Erk; Scherberger, Hansjörg
2011-10-05
Despite recent advances in harnessing cortical motor-related activity to control computer cursors and robotic devices, the ability to decode and execute different grasping patterns remains a major obstacle. Here we demonstrate a simple Bayesian decoder for real-time classification of grip type and wrist orientation in macaque monkeys that uses higher-order planning signals from anterior intraparietal cortex (AIP) and ventral premotor cortex (area F5). Real-time decoding was based on multiunit signals, which had similar tuning properties to cells in previous single-unit recording studies. Maximum decoding accuracy for two grasp types (power and precision grip) and five wrist orientations was 63% (chance level, 10%). Analysis of decoder performance showed that grip type decoding was highly accurate (90.6%), with most errors occurring during orientation classification. In a subsequent off-line analysis, we found small but significant performance improvements (mean, 6.25 percentage points) when using an optimized spike-sorting method (superparamagnetic clustering). Furthermore, we observed significant differences in the contributions of F5 and AIP for grasp decoding, with F5 being better suited for classification of the grip type and AIP contributing more toward decoding of object orientation. However, optimum decoding performance was maximal when using neural activity simultaneously from both areas. Overall, these results highlight quantitative differences in the functional representation of grasp movements in AIP and F5 and represent a first step toward using these signals for developing functional neural interfaces for hand grasping.
COGNITION, ACTION, AND OBJECT MANIPULATION
Rosenbaum, David A.; Chapman, Kate M.; Weigelt, Matthias; Weiss, Daniel J.; van der Wel, Robrecht
2012-01-01
Although psychology is the science of mental life and behavior, it has paid little attention to the means by which mental life is translated into behavior. One domain where links between cognition and action have been explored is the manipulation of objects. This article reviews psychological research on this topic, with special emphasis on the tendency to grasp objects differently depending on what one plans to do with the objects. Such differential grasping has been demonstrated in a wide range of object manipulation tasks, including grasping an object in a way that reveals anticipation of the object's future orientation, height, and required placement precision. Differential grasping has also been demonstrated in a wide range of behaviors, including one-hand grasps, two-hand grasps, walking, and transferring objects from place to place as well as from person to person. The populations in whom the tendency has been shown are also diverse, including nonhuman primates as well as human adults, children, and babies. Meanwhile, the tendency is compromised in a variety of clinical populations and in children of a surprisingly advanced age. Verbal working memory is compromised as well if words are memorized while object manipulation tasks are performed; the recency portion of the serial position curve is reduced in this circumstance. In general, the research reviewed here points to rich connections between cognition and action as revealed through the study of object manipulation. Other implications concern affordances, Donders' Law, and naturalistic observation and the teaching of psychology. PMID:22448912
Low-cost silicon solar array project environmental hail model for assessing risk to solar collectors
NASA Technical Reports Server (NTRS)
Gonzalez, C.
1977-01-01
The probability of solar arrays being struck by hailstones of various sizes as a function of geographic location and service life was assessed. The study complements parallel studies of solar array sensitivity to hail damage, the final objective being an estimate of the most cost effective level for solar array hail protection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grant, Robert
Under this grant, three significant software packages were developed or improved, all with the goal of improving the ease-of-use of HPC libraries. The first component is a Python package, named DistArray (originally named Odin), that provides a high-level interface to distributed array computing. This interface is based on the popular and widely used NumPy package and is integrated with the IPython project for enhanced interactive parallel distributed computing. The second Python package is the Distributed Array Protocol (DAP) that enables separate distributed array libraries to share arrays efficiently without copying or sending messages. If a distributed array library supports themore » DAP, it is then automatically able to communicate with any other library that also supports the protocol. This protocol allows DistArray to communicate with the Trilinos library via PyTrilinos, which was also enhanced during this project. A third package, PyTrilinos, was extended to support distributed structured arrays (in addition to the unstructured arrays of its original design), allow more flexible distributed arrays (i.e., the restriction to double precision data was lifted), and implement the DAP. DAP support includes both exporting the protocol so that external packages can use distributed Trilinos data structures, and importing the protocol so that PyTrilinos can work with distributed data from external packages.« less
Low-cost solar array project progress and plans
NASA Technical Reports Server (NTRS)
Callaghan, W. T.
1981-01-01
The considered project is part of the DOE Photovoltaic Technology and Market Development Program. This program is concerned with the development and the utilization of cost-competitive photovoltaic systems. The project has the objective to develop, by 1986, the national capability to manufacture low-cost, long-life photovoltaic arrays at production rates that will realize economies of scale, and at a price of less than $0.70/watt. The array performance objectives include an efficiency greater than 10% and an operating lifetime longer than 20 years. The objective of the silicon material task is to establish the practicality of processes for producing silicon suitable for terrestrial photovoltaic applications at a price of $14/kg. The large-area sheet task is concerned with the development of process technology for sheet formation. Low-cost encapsulation material systems are being developed in connection with the encapsulation task. Another project goal is related to the development of economical process sequences.
Rana computatrix to human language: towards a computational neuroethology of language evolution.
Arbib, Michael A
2003-10-15
Walter's Machina speculatrix inspired the name Rana computatrix for a family of models of visuomotor coordination in the frog, which contributed to the development of computational neuroethology. We offer here an 'evolutionary' perspective on models in the same tradition for rat, monkey and human. For rat, we show how the frog-like taxon affordance model provides a basis for the spatial navigation mechanisms that involve the hippocampus and other brain regions. For monkey, we recall two models of neural mechanisms for visuomotor coordination. The first, for saccades, shows how interactions between the parietal and frontal cortex augment superior colliculus seen as the homologue of frog tectum. The second, for grasping, continues the theme of parieto-frontal interactions, linking parietal affordances to motor schemas in premotor cortex. It further emphasizes the mirror system for grasping, in which neurons are active both when the monkey executes a specific grasp and when it observes a similar grasp executed by others. The model of human-brain mechanisms is based on the mirror-system hypothesis of the evolution of the language-ready brain, which sees the human Broca's area as an evolved extension of the mirror system for grasping.
Humanoid Mobile Manipulation Using Controller Refinement
NASA Technical Reports Server (NTRS)
Platt, Robert; Burridge, Robert; Diftler, Myron; Graf, Jodi; Goza, Mike; Huber, Eric; Brock, Oliver
2006-01-01
An important class of mobile manipulation problems are move-to-grasp problems where a mobile robot must navigate to and pick up an object. One of the distinguishing features of this class of tasks is its coarse-to-fine structure. Near the beginning of the task, the robot can only sense the target object coarsely or indirectly and make gross motion toward the object. However, after the robot has located and approached the object, the robot must finely control its grasping contacts using precise visual and haptic feedback. This paper proposes that move-to-grasp problems are naturally solved by a sequence of controllers that iteratively refines what ultimately becomes the final solution. This paper introduces the notion of a refining sequence of controllers and characterizes this type of solution. The approach is demonstrated in a move-to-grasp task where Robonaut, the NASA/JSC dexterous humanoid, is mounted on a mobile base and navigates to and picks up a geological sample box. In a series of tests, it is shown that a refining sequence of controllers decreases variance in robot configuration relative to the sample box until a successful grasp has been achieved.
Improvement and Neuroplasticity after Combined Rehabilitation to Forced Grasping
Ogata, Atsuko; Kawahira, Kazumi; Shimodozono, Megumi
2017-01-01
The grasp reflex is a distressing symptom but the need to treat or suppress it has rarely been discussed in the literature. We report the case of a 17-year-old man who had suffered cerebral infarction of the right putamen and temporal lobe 10 years previously. Forced grasping of the hemiparetic left upper limb was improved after a unique combined treatment. Botulinum toxin type A (BTX-A) was first injected into the left biceps, wrist flexor muscles, and finger flexor muscles. Forced grasping was reduced along with spasticity of the upper limb. In addition, repetitive facilitative exercise and object-related training were performed under low-amplitude continuous neuromuscular electrical stimulation. Since this 2-week treatment improved upper limb function, we compared brain activities, as measured by near-infrared spectroscopy during finger pinching, before and after the combined treatment. Brain activities in the ipsilesional sensorimotor cortex (SMC) and medial frontal cortex (MFC) during pinching under electrical stimulation after treatment were greater than those before. The results suggest that training under electrical stimulation after BTX-A treatment may modulate the activities of the ipsilesional SMC and MFC and lead to functional improvement of the affected upper limb with forced grasping. PMID:28265475
NASA Astrophysics Data System (ADS)
Kim, Hyeon-Min; Yoon, Joungwon; Shin, Hee-Suk; Kim, Gab-Soon
2012-02-01
Some patients cannot use their hands because of the paralysis of their fingers. Their fingers can recover with rehabilitative training, and the extent of rehabilitation can be judged by grasping a cylindrical-object with their fingers. At present, the cylindrical-object used in hospitals is only a plastic cylinder, which cannot measure grasping force of the fingers. Therefore, doctors must judge the extent of rehabilitation by watching patients' fingers as they grasp the plastic cylinder. In this paper, the development of two cylindrical-type finger force measuring systems with four force sensors for left hand and right hand were developed. The developed finger force measuring system can measure the grasping force of patients' each finger (forefinger, middle finger, ring finger and little finger), and the measured results could be used to judge the rehabilitation extent of a finger patient. The grasping force tests of men and women were performed using the developed cylindrical-type finger force measuring systems. The tests confirm that the average finger forces of right hand and left hand for men were about 194 N and 179 N, and for women, 108 N and 95 N.
Strbac, Matija; Kočović, Slobodan; Marković, Marko; Popović, Dejan B
2014-01-01
We present a computer vision algorithm that incorporates a heuristic model which mimics a biological control system for the estimation of control signals used in functional electrical stimulation (FES) assisted grasping. The developed processing software acquires the data from Microsoft Kinect camera and implements real-time hand tracking and object analysis. This information can be used to identify temporal synchrony and spatial synergies modalities for FES control. Therefore, the algorithm acts as artificial perception which mimics human visual perception by identifying the position and shape of the object with respect to the position of the hand in real time during the planning phase of the grasp. This artificial perception used within the heuristically developed model allows selection of the appropriate grasp and prehension. The experiments demonstrate that correct grasp modality was selected in more than 90% of tested scenarios/objects. The system is portable, and the components are low in cost and robust; hence, it can be used for the FES in clinical or even home environment. The main application of the system is envisioned for functional electrical therapy, that is, intensive exercise assisted with FES.
Grasping with mechanical intelligence. M.S. Thesis
NASA Technical Reports Server (NTRS)
Ulrich, Nathan Thatcher
1988-01-01
Many robotic hands have been designed and a number have been built. Because of the difficulty of controlling and using complex hands, which usually have nine or more degrees of freedom, the simple one- or two-degree-of-freedom gripper is still the most common robotic end effector. A new category of device is presented: a medium-complexity end effector. With three to five degrees of freedom, such a tool is much easier to control and use, as well as more economical, compact and lightweight than complex hands. In order to increase the versatility, it was necessary to identify grasping primitives and to implement them in the mechanism. In addition, power and enveloping grasps are stressed over fingertip and precision grasps. The design is based upon analysis of object apprehension types, requisite characteristics for active sensing, and a determination of necessary environmental interactions. Contained are the general concepts necessary to the design of a medium-complexity end effector, an analysis of typical performance, and a computer simulation of a grasp planning algorithm specific to this type of mechanism. Finally, some details concerning the UPenn Hand-a tool designed for the research laboratory-are presented.
Humanoid Mobile Manipulation Using Controller Refinement
NASA Technical Reports Server (NTRS)
Platt, Robert; Burridge, Robert; Diftler, Myron; Graf, Jodi; Goza, Mike; Huber, Eric
2006-01-01
An important class of mobile manipulation problems are move-to-grasp problems where a mobile robot must navigate to and pick up an object. One of the distinguishing features of this class of tasks is its coarse-to-fine structure. Near the beginning of the task, the robot can only sense the target object coarsely or indirectly and make gross motion toward the object. However, after the robot has located and approached the object, the robot must finely control its grasping contacts using precise visual and haptic feedback. In this paper, it is proposed that move-to-grasp problems are naturally solved by a sequence of controllers that iteratively refines what ultimately becomes the final solution. This paper introduces the notion of a refining sequence of controllers and characterizes this type of solution. The approach is demonstrated in a move-to-grasp task where Robonaut, the NASA/JSC dexterous humanoid, is mounted on a mobile base and navigates to and picks up a geological sample box. In a series of tests, it is shown that a refining sequence of controllers decreases variance in robot configuration relative to the sample box until a successful grasp has been achieved.
An electromyographic analysis of two handwriting grasp patterns.
de Almeida, Pedro Henrique Tavares Queiroz; da Cruz, Daniel Marinho Cezar; Magna, Luis Alberto; Ferrigno, Iracema Serrat Vergotti
2013-08-01
Handwriting is a fundamental skill needed for the development of daily-life activities during lifetime and can be performed using different forms to hold the writing object. In this study, we monitored the sEMG activity of trapezius, biceps brachii, extensor carpi radialis brevis and flexor digitorum superficialis during a handwriting task with two groups of subjects using different grasp patterns. Twenty-four university students (thirteen males and eleven females; mean age of 22.04±2.8years) were included in this study. We randomly invited 12 subjects that used the Dynamic Tripod grasp and 12 subjects that used the Static Tripod grasp. The static tripod group showed statistically significant changes in the sEMG activity of trapezium and biceps brachii muscles during handwriting when compared to dynamic tripod group's subjects. No significant differences were found in extensor carpi radialis brevis and flexor digitorum superficialis activities among the two groups. The findings in this study suggest an increased activity of proximal muscles among subjects using a transitional grasp, indicating potential higher energy expenditure and muscular harm with the maintenance of this motor pattern in handwriting tasks, especially during the progression in academic life. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kočović, Slobodan; Popović, Dejan B.
2014-01-01
We present a computer vision algorithm that incorporates a heuristic model which mimics a biological control system for the estimation of control signals used in functional electrical stimulation (FES) assisted grasping. The developed processing software acquires the data from Microsoft Kinect camera and implements real-time hand tracking and object analysis. This information can be used to identify temporal synchrony and spatial synergies modalities for FES control. Therefore, the algorithm acts as artificial perception which mimics human visual perception by identifying the position and shape of the object with respect to the position of the hand in real time during the planning phase of the grasp. This artificial perception used within the heuristically developed model allows selection of the appropriate grasp and prehension. The experiments demonstrate that correct grasp modality was selected in more than 90% of tested scenarios/objects. The system is portable, and the components are low in cost and robust; hence, it can be used for the FES in clinical or even home environment. The main application of the system is envisioned for functional electrical therapy, that is, intensive exercise assisted with FES. PMID:25202707
Interactions between dorsal and ventral streams for controlling skilled grasp
van Polanen, Vonne; Davare, Marco
2015-01-01
The two visual systems hypothesis suggests processing of visual information into two distinct routes in the brain: a dorsal stream for the control of actions and a ventral stream for the identification of objects. Recently, increasing evidence has shown that the dorsal and ventral streams are not strictly independent, but do interact with each other. In this paper, we argue that the interactions between dorsal and ventral streams are important for controlling complex object-oriented hand movements, especially skilled grasp. Anatomical studies have reported the existence of direct connections between dorsal and ventral stream areas. These physiological interconnections appear to be gradually more active as the precision demands of the grasp become higher. It is hypothesised that the dorsal stream needs to retrieve detailed information about object identity, stored in ventral stream areas, when the object properties require complex fine-tuning of the grasp. In turn, the ventral stream might receive up to date grasp-related information from dorsal stream areas to refine the object internal representation. Future research will provide direct evidence for which specific areas of the two streams interact, the timing of their interactions and in which behavioural context they occur. PMID:26169317
Differential effects of delay upon visually and haptically guided grasping and perceptual judgments.
Pettypiece, Charles E; Culham, Jody C; Goodale, Melvyn A
2009-05-01
Experiments with visual illusions have revealed a dissociation between the systems that mediate object perception and those responsible for object-directed action. More recently, an experiment on a haptic version of the visual size-contrast illusion has provided evidence for the notion that the haptic modality shows a similar dissociation when grasping and estimating the size of objects in real-time. Here we present evidence suggesting that the similarities between the two modalities begin to break down once a delay is introduced between when people feel the target object and when they perform the grasp or estimation. In particular, when grasping after a delay in a haptic paradigm, people scale their grasps differently when the target is presented with a flanking object of a different size (although the difference does not reflect a size-contrast effect). When estimating after a delay, however, it appears that people ignore the size of the flanking objects entirely. This does not fit well with the results commonly found in visual experiments. Thus, introducing a delay reveals important differences in the way in which haptic and visual memories are stored and accessed.
RoBlock: a prototype autonomous manufacturing cell
NASA Astrophysics Data System (ADS)
Baekdal, Lars K.; Balslev, Ivar; Eriksen, Rene D.; Jensen, Soren P.; Jorgensen, Bo N.; Kirstein, Brian; Kristensen, Bent B.; Olsen, Martin M.; Perram, John W.; Petersen, Henrik G.; Petersen, Morten L.; Ruhoff, Peter T.; Skjolstrup, Carl E.; Sorensen, Anders S.; Wagenaar, Jeroen M.
2000-10-01
RoBlock is the first phase of an internally financed project at the Institute aimed at building a system in which two industrial robots suspended from a gantry, as shown below, cooperate to perform a task specified by an external user, in this case, assembling an unstructured collection of colored wooden blocks into a specified 3D pattern. The blocks are identified and localized using computer vision and grasped with a suction cup mechanism. Future phases of the project will involve other processes such as grasping and lifting, as well as other types of robot such as autonomous vehicles or variable geometry trusses. Innovative features of the control software system include: The use of an advanced trajectory planning system which ensures collision avoidance based on a generalization of the method of artificial potential fields, the use of a generic model-based controller which learns the values of parameters, including static and kinetic friction, of a detailed mechanical model of itself by comparing actual with planned movements, the use of fast, flexible, and robust pattern recognition and 3D-interpretation strategies, integration of trajectory planning and control with the sensor systems in a distributed Java application running on a network of PC's attached to the individual physical components. In designing this first stage, the aim was to build in the minimum complexity necessary to make the system non-trivially autonomous and to minimize the technological risks. The aims of this project, which is planned to be operational during 2000, are as follows: To provide a platform for carrying out experimental research in multi-agent systems and autonomous manufacturing systems, to test the interdisciplinary cooperation architecture of the Maersk Institute, in which researchers in the fields of applied mathematics (modeling the physical world), software engineering (modeling the system) and sensor/actuator technology (relating the virtual and real worlds) could collaborate with systems integrators to construct intelligent, autonomous systems, and to provide a showpiece demonstrator in the entrance hall of the Institute's new building.
NASA Astrophysics Data System (ADS)
Takita, Masato
2017-06-01
We have started up the ALPACA (Andes Large area PArticle detector for Cosmic ray physics and Astronomy) project. The ALPACA experiment is composed of an 83,000 m2 air shower array and a 5,400 m2 underground muon detector array to make wide field-of-view high-sensitivity observations of high-energy cosmic rays/cosmic gamma rays on the Cerro Estuqueria highland, 4,740 m above sea level around Mount Chacaltaya, Bolivia. We briefly report on the design concept of the new project and its physics targets.
Supporting Current Energy Conversion Projects through Numerical Modeling
NASA Astrophysics Data System (ADS)
James, S. C.; Roberts, J.
2016-02-01
The primary goals of current energy conversion (CEC) technology being developed today are to optimize energy output and minimize environmental impact. CEC turbines generate energy from tidal and current systems and create wakes that interact with turbines located downstream of a device. The placement of devices can greatly influence power generation and structural reliability. CECs can also alter the environment surrounding the turbines, such as flow regimes, sediment dynamics, and water quality. These alterations pose potential stressors to numerous environmental receptors. Software is needed to investigate specific CEC sites to simulate power generation and hydrodynamic responses of a flow through a CEC turbine array so that these potential impacts can be evaluated. Moreover, this software can be used to optimize array layouts that yield the least changes to the environmental (i.e., hydrodynamics, sediment dynamics, and water quality). Through model calibration exercises, simulated wake profiles and turbulence intensities compare favorably to the experimental data and demonstrate the utility and accuracy of a fast-running tool for future siting and analysis of CEC arrays in complex domains. The Delft3D modeling tool facilitates siting of CEC projects through optimization of array layouts and evaluation of potential environmental effect all while provide a common "language" for academics, industry, and regulators to be able to discuss the implications of marine renewable energy projects. Given the enormity of any full-scale marine renewable energy project, it necessarily falls to modeling to evaluate how array operations must be addressed in an environmental impact statement in a way that engenders confidence in the assessment of the CEC array to minimize environmental effects.
NASA Technical Reports Server (NTRS)
Cross, James H., II
1991-01-01
The main objective is the investigation, formulation, and generation of graphical representations of algorithms, structures, and processes for Ada (GRASP/Ada). The presented task, in which various graphical representations that can be extracted or generated from source code are described and categorized, is focused on reverse engineering. The following subject areas are covered: the system model; control structure diagram generator; object oriented design diagram generator; user interface; and the GRASP library.
NASA Astrophysics Data System (ADS)
Stetson, Suzanne; Weber, Hadley; Crosby, Frank J.; Tinsley, Kenneth; Kloess, Edmund; Nevis, Andrew J.; Holloway, John H., Jr.; Witherspoon, Ned H.
2004-09-01
The Airborne Littoral Reconnaissance Technologies (ALRT) project has developed and tested a nighttime operational minefield detection capability using commercial off-the-shelf high-power Laser Diode Arrays (LDAs). The Coastal System Station"s ALRT project, under funding from the Office of Naval Research (ONR), has been designing, developing, integrating, and testing commercial arrays using a Cessna airborne platform over the last several years. This has led to the development of the Airborne Laser Diode Array Illuminator wide field-of-view (ALDAI-W) imaging test bed system. The ALRT project tested ALDAI-W at the Army"s Night Vision Lab"s Airborne Mine Detection Arid Test. By participating in Night Vision"s test, ALRT was able to collect initial prototype nighttime operational data using ALDAI-W, showing impressive results and pioneering the way for final test bed demonstration conducted in September 2003. This paper describes the ALDAI-W Arid Test and results, along with processing steps used to generate imagery.
Subarray Processing for Projection-based RFI Mitigation in Radio Astronomical Interferometers
NASA Astrophysics Data System (ADS)
Burnett, Mitchell C.; Jeffs, Brian D.; Black, Richard A.; Warnick, Karl F.
2018-04-01
Radio Frequency Interference (RFI) is a major problem for observations in Radio Astronomy (RA). Adaptive spatial filtering techniques such as subspace projection are promising candidates for RFI mitigation; however, for radio interferometric imaging arrays, these have primarily been used in engineering demonstration experiments rather than mainstream scientific observations. This paper considers one reason that adoption of such algorithms is limited: RFI decorrelates across the interferometric array because of long baseline lengths. This occurs when the relative RFI time delay along a baseline is large compared to the frequency channel inverse bandwidth used in the processing chain. Maximum achievable excision of the RFI is limited by covariance matrix estimation error when identifying interference subspace parameters, and decorrelation of the RFI introduces errors that corrupt the subspace estimate, rendering subspace projection ineffective over the entire array. In this work, we present an algorithm that overcomes this challenge of decorrelation by applying subspace projection via subarray processing (SP-SAP). Each subarray is designed to have a set of elements with high mutual correlation in the interferer for better estimation of subspace parameters. In an RFI simulation scenario for the proposed ngVLA interferometric imaging array with 15 kHz channel bandwidth for correlator processing, we show that compared to the former approach of applying subspace projection on the full array, SP-SAP improves mitigation of the RFI on the order of 9 dB. An example of improved image synthesis and reduced RFI artifacts for a simulated image “phantom” using the SP-SAP algorithm is presented.
Getting the right grasp on executive function
Gonzalez, Claudia L. R.; Mills, Kelly J.; Genee, Inge; Li, Fangfang; Piquette, Noella; Rosen, Nicole; Gibb, Robbin
2014-01-01
Executive Function (EF) refers to important socio-emotional and cognitive skills that are known to be highly correlated with both academic and life success. EF is a blanket term that is considered to include self-regulation, working memory, and planning. Recent studies have shown a relationship between EF and motor control. The emergence of motor control coincides with that of EF, hence understanding the relationship between these two domains could have significant implications for early detection and remediation of later EF deficits. The purpose of the current study was to investigate this relationship in young children. This study incorporated the Behavioral Rating Inventory of Executive Function (BRIEF) and two motor assessments with a focus on precision grasping to test this hypothesis. The BRIEF is comprised of two indices of EF: (1) the Behavioral Regulation Index (BRI) containing three subscales: Inhibit, Shift, and Emotional Control; (2) the Metacognition Index (MI) containing five subscales: Initiate, Working Memory, Plan/Organize, Organization of Materials, and Monitor. A global executive composite (GEC) is derived from the two indices. In this study, right-handed children aged 5–6 and 9–10 were asked to: grasp-to-construct (Lego® models); and grasp-to-place (wooden blocks), while their parents completed the BRIEF questionnaire. Analysis of results indicated significant correlations between the strength of right hand preference for grasping and numerous elements of the BRIEF including the BRI, MI, and GEC. Specifically, the more the right hand was used for grasping the better the EF ratings. In addition, patterns of space-use correlated with the GEC in several subscales of the BRIEF. Finally and remarkably, the results also showed a reciprocal relationship between hand and space use for grasping and EF. These findings are discussed with respect to: (1) the developmental overlap of motor and executive functions; (2) detection of EF deficits through tasks that measure lateralization of hand and space use; and (3) the possibility of using motor interventions to remediate EF deficits. PMID:24778624
An investigation of the tri-bar gripping system on isometric muscular endurance.
Drury, Daniel G; Faggiono, Heath; Stuempfle, Kristin J
2004-11-01
Recently, a new product called the Tri-Bar has been introduced as an alternative to the standard round weightlifting bar. The Tri-Bar has the same weight, length, and circumference as a standard weightlifting bar and differs only in that the shape of the bar is formed like a triangle with rounded edges. Theoretically, the shape of the bar will enhance gripping comfort and increase muscular endurance. We studied 32 moderately trained males who were free from upper-body injury or limitation. Each participant completed 4 visits to the lab as part of 2 separate investigations. The first investigation was a comparison of straight-arm hang times while grasping a standard Olympic bar or a Tri-Bar attached to the top of a power rack. The second investigation involved grasping a standard revolving cable handle or a Tri-Bar revolving handle attached to a weight equal to half the subject's body weight. In both investigations, time was used as a measure of isometric muscular endurance. Differences were determined using a dependent t-test, and a level of significance was set at p < 0.05. Mean hang times were significantly longer when the men hung from the Tri-Bar (107.6 seconds) versus the standard bar (95.4 seconds) (p = 0.015). Conversely, in the investigation using the revolving handles, the round bar produced longer grasping times (71.5 seconds) than the Tri-Bar (62.6 seconds) (p = 0.000). The results of this investigation indicate that a fixed and stable Tri-Bar may help to increase hang time, but a Tri-Bar free to rotate within the grasp may decrease grasping time in comparison to a standard round handle. With regard to exercises that require isometric grasping, the Tri-Bar may be an effective alternative to the standard bar for increasing isometric grasping endurance.
de Bruin, Natalie; Bryant, Devon C.; Gonzalez, Claudia L. R.
2014-01-01
Hemispatial neglect is a common outcome of stroke that is characterized by the inability to orient toward, and attend to stimuli in contralesional space. It is established that hemispatial neglect has a perceptual component, however, the presence and severity of motor impairments is controversial. Establishing the nature of space use and spatial biases during visually guided actions amongst healthy individuals is critical to understanding the presence of visuomotor deficits in patients with neglect. Accordingly, three experiments were conducted to investigate the effect of object spatial location on patterns of grasping. Experiment 1 required right-handed participants to reach and grasp for blocks in order to construct 3D models. The blocks were scattered on a tabletop divided into equal size quadrants: left near, left far, right near, and right far. Identical sets of building blocks were available in each quadrant. Space use was dynamic, with participants initially grasping blocks from right near space and tending to “neglect” left far space until the final stages of the task. Experiment 2 repeated the protocol with left-handed participants. Remarkably, left-handed participants displayed a similar pattern of space use to right-handed participants. In Experiment 3 eye movements were examined to investigate whether “neglect” for grasping in left far reachable space had its origins in attentional biases. It was found that patterns of eye movements mirrored patterns of reach-to-grasp movements. We conclude that there are spatial biases during visually guided grasping, specifically, a tendency to neglect left far reachable space, and that this “neglect” is attentional in origin. The results raise the possibility that visuomotor impairments reported among patients with right hemisphere lesions when working in contralesional space may result in part from this inherent tendency to “neglect” left far space irrespective of the presence of unilateral visuospatial neglect. PMID:24478751
Temporal-spatial parameters of the upper limb during a Reach & Grasp Cycle for children.
Butler, Erin E; Ladd, Amy L; Lamont, Lauren E; Rose, Jessica
2010-07-01
The objective of this study was to characterize normal temporal-spatial patterns during the Reach & Grasp Cycle and to identify upper limb motor deficits in children with cerebral palsy (CP). The Reach & Grasp Cycle encompasses six sequential tasks: reach, grasp cylinder, transport to self (T(1)), transport back to table (T(2)), release cylinder, and return to initial position. Three-dimensional motion data were recorded from 25 typically developing children (11 males, 14 females; ages 5-18 years) and 12 children with hemiplegic CP (2 males, 10 females; ages 5-17 years). Within-day and between-day coefficients of variation for the control group ranged from 0 to 0.19, indicating good repeatability of all parameters. The mean duration of the Cycle for children with CP was nearly twice as long as controls, 9.5±4.3s versus 5.1±1.2s (U=37.0, P=.002), partly due to prolonged grasp and release durations. Peak hand velocity occurred at approximately 40% of each phase and was greater during the transport (T(1), T(2)) than non-transport phases (reach, return) in controls (P<.001). Index of curvature was lower during transport versus non-transport phases for all children. Children with CP demonstrated an increased index of curvature during reach (U=46.0, P=.0074) and an increased total number of movement units (U=16.5, P<.0001) compared to controls, indicating less efficient and less smooth movements. Total duration of the Reach & Grasp Cycle (rho=.957, P<.0001), index of curvature during reach and T(1) (rho=.873, P=.0002 and rho=.778, P=.0028), and total number of movement units (rho=.907, P<.0001) correlated strongly with MACS score. The consistent normative data and the substantial differences between children with CP and controls reflect utility of the Reach & Grasp Cycle for quantitative evaluation of upper limb motor deficits. Copyright © 2010 Elsevier B.V. All rights reserved.
Raghavan, Preeti; Santello, Marco; Gordon, Andrew M; Krakauer, John W
2010-06-01
Efficient grasping requires planned and accurate coordination of finger movements to approximate the shape of an object before contact. In healthy subjects, hand shaping is known to occur early in reach under predominantly feedforward control. In patients with hemiparesis after stroke, execution of coordinated digit motion during grasping is impaired as a result of damage to the corticospinal tract. The question addressed here is whether patients with hemiparesis are able to compensate for their execution deficit with a qualitatively different grasp strategy that still allows them to differentiate hand posture to object shape. Subjects grasped a rectangular, concave, and convex object while wearing an instrumented glove. Reach-to-grasp was divided into three phases based on wrist kinematics: reach acceleration (reach onset to peak horizontal wrist velocity), reach deceleration (peak horizontal wrist velocity to reach offset), and grasp (reach offset to lift-off). Patients showed reduced finger abduction, proximal interphalangeal joint (PIP) flexion, and metacarpophalangeal joint (MCP) extension at object grasp across all three shapes compared with controls; however, they were able to partially differentiate hand posture for the convex and concave shapes using a compensatory strategy that involved increased MCP flexion rather than the PIP flexion seen in controls. Interestingly, shape-specific hand postures did not unfold initially during reach acceleration as seen in controls, but instead evolved later during reach deceleration, which suggests increased reliance on sensory feedback. These results indicate that kinematic analysis can identify and quantify within-limb compensatory motor control strategies after stroke. From a clinical perspective, quantitative study of compensation is important to better understand the process of recovery from brain injury. From a motor control perspective, compensation can be considered a model for how joint redundancy is exploited to accomplish the task goal through redistribution of work across effectors.
Concentrator enhanced solar arrays design study
NASA Technical Reports Server (NTRS)
Lott, D. R.
1978-01-01
The analysis and preliminary design of a 25 kW concentrator enhanced lightweight flexible solar array are presented. The study was organized into five major tasks: (1) assessment and specification of design requirements; (2) mechanical design; (3) electric design; (4) concentrator design; and (5) cost projection. The tasks were conducted in an iterative manner so as to best derive a baseline design selection. The objectives of the study are discussed and comparative configurations and mass data on the SEP (Solar Electric Propulsion) array design, concentrator design options and configuration/mass data on the selected concentrator enhanced solar array baseline design are presented. Design requirements supporting design analysis and detailed baseline design data are discussed. The results of the cost projection analysis and new technology are also discussed.
Development of autonomous grasping and navigating robot
NASA Astrophysics Data System (ADS)
Kudoh, Hiroyuki; Fujimoto, Keisuke; Nakayama, Yasuichi
2015-01-01
The ability to find and grasp target items in an unknown environment is important for working robots. We developed an autonomous navigating and grasping robot. The operations are locating a requested item, moving to where the item is placed, finding the item on a shelf or table, and picking the item up from the shelf or the table. To achieve these operations, we designed the robot with three functions: an autonomous navigating function that generates a map and a route in an unknown environment, an item position recognizing function, and a grasping function. We tested this robot in an unknown environment. It achieved a series of operations: moving to a destination, recognizing the positions of items on a shelf, picking up an item, placing it on a cart with its hand, and returning to the starting location. The results of this experiment show the applicability of reducing the workforce with robots.
Human Grasp Assist Device With Exoskeleton
NASA Technical Reports Server (NTRS)
Bergelin, Bryan J (Inventor); Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Linn, Douglas Martin (Inventor); Bridgwater, Lyndon B. J. (Inventor)
2014-01-01
A grasp assist system includes a glove, actuator assembly, and controller. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. Phalange rings are positioned with respect to the digit. A flexible tendon is connected at one end to one of the rings and is routed through the remaining rings. An exoskeleton positioned with respect to the digit includes hinged interconnecting members each connected to a corresponding ring, and/or a single piece of slotted material. The actuator assembly is connected to another end of the tendon. The controller calculates a tensile force in response to the measured grasping force, and commands the tensile force from the actuator assembly to thereby pull on the tendon. The exoskeleton offloads some of the tensile force from the operator's finger to the glove.
Twelve-Month-Olds' Understanding of Intention Transfer through Communication
Cheung, Him; Xiao, Wen; Lai, Ching Man
2012-01-01
Do infants understand that intention can be transferred through communication? We answered this question by examining 12-month-olds' looking times in a violation-of-expectation paradigm with two human agents. In familiarization, the non-acting agent spoke, clapped her hands, read aloud a book, or remained silent before the acting agent grasped one (the target) of two objects. During test only the non-actor remained, grasping either the target or distractor. The infants looked longer in the distractor than target condition, suggesting violation of expectation, only if the non-actor had spoken or clapped in familiarization. Because the non-actor never had grasped any of the objects in familiarization, the infants' expectation on her behavior could have developed from the understanding that her intention was transferred to the actor, who executed it by grasping the target in familiarization, via speaking and clapping as acts of communication (but not reading aloud and remaining silent). PMID:23029427
Twelve-month-olds' understanding of intention transfer through communication.
Cheung, Him; Xiao, Wen; Lai, Ching Man
2012-01-01
Do infants understand that intention can be transferred through communication? We answered this question by examining 12-month-olds' looking times in a violation-of-expectation paradigm with two human agents. In familiarization, the non-acting agent spoke, clapped her hands, read aloud a book, or remained silent before the acting agent grasped one (the target) of two objects. During test only the non-actor remained, grasping either the target or distractor. The infants looked longer in the distractor than target condition, suggesting violation of expectation, only if the non-actor had spoken or clapped in familiarization. Because the non-actor never had grasped any of the objects in familiarization, the infants' expectation on her behavior could have developed from the understanding that her intention was transferred to the actor, who executed it by grasping the target in familiarization, via speaking and clapping as acts of communication (but not reading aloud and remaining silent).
Human Grasp Assist Device Soft Goods
NASA Technical Reports Server (NTRS)
Ihrke, Chris A. (Inventor); Davis, Donald R. (Inventor); Bergelin, Bryan (Inventor); Bridgwater, Lyndon B. J. (Inventor); Bibby, Heather (Inventor); Schroeder, Judy (Inventor); Linn, Douglas Martin (Inventor); Erkkila, Craig (Inventor)
2015-01-01
A grasp assist system includes a glove and a flexible sleeve. The glove includes a digit such as a finger or thumb, a force sensor configured to measure a grasping force applied to an object by an operator wearing the glove, and adjustable phalange rings positioned with respect to the digit. A saddle is positioned with respect to the finger. A flexible tendon is looped at one end around the saddle. A conduit contains the tendon. A conduit anchor secured within a palm of the glove receives the conduit. The sleeve has pockets containing an actuator assembly connected to another end of the tendon and a controller. The controller is in communication with the force sensor, and calculates a tensile force in response to the measured grasping force. The controller commands the tensile force from the actuator assembly to tension the tendon and thereby move the finger.
Smart hands for the EVA retriever
NASA Technical Reports Server (NTRS)
Hess, Clifford W.; Li, Larry C.
1990-01-01
Dexterous, robotic hands are required for the extravehicular activity retriever (EVAR) system being developed by the NASA Johnson Space Center (JSC). These hands, as part of the EVAR system, must be able to grasp objects autonomously and securely which inadvertently separate from the Space Station. Development of the required hands was initiated in 1987. Outlined here are the hand development activities, including design considerations, progress to date, and future plans. Several types of dexterous hands that were evaluated, along with a proximity-sensing capability that was developed to initiate a reflexive, adaptive grasp, are described. The evaluations resulted in the design and fabrication of a 6-degree-of-freedom (DOF) hand that has two fingers and a thumb arranged in an anthropomorphic configuration. Finger joint force and position sensors are included in the design, as well as infrared proximity sensors which allow initiation of the grasp sequence when an object is detected within the grasp envelope.
Synthesis Study of a 6-Element Non-Uniform Array with Tilted Elements for CLARREO Project
NASA Technical Reports Server (NTRS)
Jamnejad, Vahraz; Hoorfar, Ahmad
2012-01-01
This paper presents the results of a preliminary study of the gain/pattern properties of a 6-element Radio Occultation (RO) array for the proposed CLARREO (Climate Absolute Radiance and Refractivity Observatory (CLARREO) Project. CLARREO is one of the 4 highest priority missions recommended in the National Research Council Earth Science Decadal Survey.
Space-Based Telemetry and Range Safety Project Ku-Band and Ka-Band Phased Array Antenna
NASA Technical Reports Server (NTRS)
Whiteman, Donald E.; Valencia, Lisa M.; Birr, Richard B.
2005-01-01
The National Aeronautics and Space Administration Space-Based Telemetry and Range Safety study is a multiphase project to increase data rates and flexibility and decrease costs by using space-based communications assets for telemetry during launches and landings. Phase 1 used standard S-band antennas with the Tracking and Data Relay Satellite System to obtain a baseline performance. The selection process and available resources for Phase 2 resulted in a Ku-band phased array antenna system. Several development efforts are under way for a Ka-band phased array antenna system for Phase 3. Each phase includes test flights to demonstrate performance and capabilities. Successful completion of this project will result in a set of communications requirements for the next generation of launch vehicles.
Ku- and Ka-Band Phased Array Antenna for the Space-Based Telemetry and Range Safety Project
NASA Technical Reports Server (NTRS)
Whiteman, Donald E.; Valencia, Lisa M.; Birr, Richard B.
2005-01-01
The National Aeronautics and Space Administration Space-Based Telemetry and Range Safety study is a multiphase project to increase data rates and flexibility and decrease costs by using space-based communications assets for telemetry during launches and landings. Phase 1 used standard S-band antennas with the Tracking and Data Relay Satellite System to obtain a baseline performance. The selection process and available resources for Phase 2 resulted in a Ku-band phased array antenna system. Several development efforts are under way for a Ka-band phased array antenna system for Phase 3. Each phase includes test flights to demonstrate performance and capabilities. Successful completion of this project will result in a set of communications requirements for the next generation of launch vehicles.
Volitional and automatic control of the hand when reaching to grasp objects.
Chen, Zhongting; Saunders, Jeffrey Allen
2018-06-01
When picking up an object, we tend to grasp at contact points that allow a stable grip. Recent studies have demonstrated that appropriate grasp points can be selected during an ongoing movement in response to unexpected perturbations of the target object. In this study, we tested whether such online grip adjustments are automatic responses or can be controlled volitionally. Subjects performed virtual grasping movements toward target 2D shapes that sometimes changed shape or orientation during movement. Unlike in previous studies, the conditions and task requirements discouraged any online adjustments toward the perturbed shapes. In Experiment 1, target shapes were perturbed briefly (200 ms) during movement before reverting to the original shape, and subjects were instructed to ignore the transient perturbations. Despite subjects' intentions, we observed online adjustments of grip orientation that were toward the expected grip axis of the briefly presented shape. In Experiment 2, we added a stop-signal to the grasping task, with target perturbation as the stop cue. We again observed unnecessary online adjustments toward the grip axis of the perturbed shape, with similar latency. Furthermore, the grip adjustments continued after the forward motion of the hand had stopped, indicating that the automatic response to the perturbed target shape co-occurred with the volitional response to the perturbation onset. Our results provide evidence that automatic control mechanisms are used to guide the fingers to appropriate grasp points and suggest that these mechanisms are distinct from those involved with volitional control. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Rapid decrement in the effects of the Ponzo display dissociates action and perception.
Whitwell, Robert L; Buckingham, Gavin; Enns, James T; Chouinard, Philippe A; Goodale, Melvyn A
2016-08-01
It has been demonstrated that pictorial illusions have a smaller influence on grasping than they do on perceptual judgments. Yet to date this work has not considered the reduced influence of an illusion as it is measured repeatedly. Here we studied this decrement in the context of a Ponzo illusion to further characterize the dissociation between vision for perception and for action. Participants first manually estimated the lengths of single targets in a Ponzo display with their thumb and index finger, then actually grasped these targets in another series of trials, and then manually estimated the target lengths again in a final set of trials. The results showed that although the perceptual estimates and grasp apertures were equally sensitive to real differences in target length on the initial trials, only the perceptual estimates remained biased by the illusion over repeated measurements. In contrast, the illusion's effect on the grasps decreased rapidly, vanishing entirely after only a few trials. Interestingly, a closer examination of the grasp data revealed that this initial effect was driven largely by undersizing the grip aperture for the display configuration in which the target was positioned between the diverging background lines (i.e., when the targets appeared to be shorter than they really were). This asymmetry between grasping apparently shorter and longer targets suggests that the sensorimotor system may initially treat the edges of the configuration as obstacles to be avoided. This finding highlights the sensorimotor system's ability to rapidly update motor programs through error feedback, manifesting as an immunity to the effects of illusion displays even after only a few trials.
Transfer of adaptation reveals shared mechanism in grasping and manual estimation.
Cesanek, Evan; Domini, Fulvio
2018-06-19
An influential idea in cognitive neuroscience is that perception and action are highly separable brain functions, implemented in distinct neural systems. In particular, this theory predicts that the functional distinction between grasping, a skilled action, and manual estimation, a type of perceptual report, should be mirrored by a split between their respective control systems. This idea has received support from a variety of dissociations, yet many of these findings have been criticized for failing to pinpoint the source of the dissociation. In this study, we devised a novel approach to this question, first targeting specific grasp control mechanisms through visuomotor adaptation, then testing whether adapted mechanisms were also involved in manual estimation - a response widely characterized as perceptual in function. Participants grasped objects in virtual reality that could appear larger or smaller than the actual physical sizes felt at the end of each grasp. After brief exposure to a size perturbation, manual estimates were biased in the same direction as the maximum grip apertures of grasping movements, indicating that the adapted mechanism is active in both tasks, regardless of the perception-action distinction. Additional experiments showed that the transfer effect generalizes broadly over space (Exp. 1B) and does not appear to arise from a change in visual perception (Exp. 2). We discuss two adaptable mechanisms that could have mediated the observed effect: (a) an afferent proprioceptive mechanism for sensing grip shape; and (b) an efferent visuomotor transformation of size information into a grip-shaping motor command. Copyright © 2018. Published by Elsevier Ltd.
An involuntary stereotypical grasp tendency pervades voluntary dynamic multifinger manipulation
Rácz, Kornelius; Brown, Daniel
2012-01-01
We used a novel apparatus with three hinged finger pads to characterize collaborative multifinger interactions during dynamic manipulation requiring individuated control of fingertip motions and forces. Subjects placed the thumb, index, and middle fingertips on each hinged finger pad and held it—unsupported—with constant total grasp force while voluntarily oscillating the thumb's pad. This task combines the need to 1) hold the object against gravity while 2) dynamically reconfiguring the grasp. Fingertip force variability in this combined motion and force task exhibited strong synchrony among normal (i.e., grasp) forces. Mechanical analysis and simulation show that such synchronous variability is unnecessary and cannot be explained solely by signal-dependent noise. Surprisingly, such variability also pervaded control tasks requiring different individuated fingertip motions and forces, but not tasks without finger individuation such as static grasp. These results critically extend notions of finger force variability by exposing and quantifying a pervasive challenge to dynamic multifinger manipulation: the need for the neural controller to carefully and continuously overlay individuated finger actions over mechanically unnecessary synchronous interactions. This is compatible with—and may explain—the phenomenology of strong coupling of hand muscles when this delicate balance is not yet developed, as in early childhood, or when disrupted, as in brain injury. We conclude that the control of healthy multifinger dynamic manipulation has barely enough neuromechanical degrees of freedom to meet the multiple demands of ecological tasks and critically depends on the continuous inhibition of synchronous grasp tendencies, which we speculate may be of vestigial evolutionary origin. PMID:22956798
Viewing geometry determines the contribution of binocular vision to the online control of grasping.
Keefe, Bruce D; Watt, Simon J
2017-12-01
Binocular vision is often assumed to make a specific, critical contribution to online visual control of grasping by providing precise information about the separation between digits and object. This account overlooks the 'viewing geometry' typically encountered in grasping, however. Separation of hand and object is rarely aligned precisely with the line of sight (the visual depth dimension), and analysis of the raw signals suggests that, for most other viewing angles, binocular feedback is less precise than monocular feedback. Thus, online grasp control relying selectively on binocular feedback would not be robust to natural changes in viewing geometry. Alternatively, sensory integration theory suggests that different signals contribute according to their relative precision, in which case the role of binocular feedback should depend on viewing geometry, rather than being 'hard-wired'. We manipulated viewing geometry, and assessed the role of binocular feedback by measuring the effects on grasping of occluding one eye at movement onset. Loss of binocular feedback resulted in a significantly less extended final slow-movement phase when hand and object were separated primarily in the frontoparallel plane (where binocular information is relatively imprecise), compared to when they were separated primarily along the line of sight (where binocular information is relatively precise). Consistent with sensory integration theory, this suggests the role of binocular (and monocular) vision in online grasp control is not a fixed, 'architectural' property of the visuo-motor system, but arises instead from the interaction of viewer and situation, allowing robust online control across natural variations in viewing geometry.
Liquid sodium testing of in-house phased array EMAT transducer for L-wave applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Bourdais, F.; Le Polles, T.; Baque, F.
2015-07-01
This paper describes the development of an in-house phased array EMAT transducer for longitudinal wave inspection in liquid sodium. The work presented herein is part of an undergoing project aimed at improving in-service inspection techniques for the ASTRID reactor project. The design process of the phased array EMAT probe is briefly explained and followed by a review of experimental test results. We first present test results obtained in the laboratory while the last part of the paper describes the liquid sodium testing and the produced ultrasound images. (authors)
Design and fabrication of microstrip antenna arrays
NASA Technical Reports Server (NTRS)
1978-01-01
A microstrip array project was conducted to demonstrate the feasibility of designing and fabricating simple, low cost, low sidelobe phased arrays with circular disk microstrip radiating elements. Design data were presented for microstrip elements and arrays including the effects of the protective covers, the mutual interaction between elements, and stripline feed network design. Low cost multilayer laminate fabrication techniques were also investigated. Utilizing this design data two C-band low sidelobe arrays were fabricated and tested: an eight-element linear and a sixty-four element planar array. These arrays incorporated stripline Butler matrix feed networks to produce a low sidelobe broadside beam.
APSA - A new generation of photovoltaic solar arrays
NASA Technical Reports Server (NTRS)
Stella, P. M.; Kurland, R. M.
1989-01-01
This paper provides details on the Advanced Photovoltaic Solar Array (APSA) wing design, fabrication, and testing. The impact of array size change on performance and mechanical characteristics is discussed. Projections for future performance enhancements that may be expected through the use of advanced solar cells presently under development are examined.
LSSA (Low-cost Silicon Solar Array) project
NASA Technical Reports Server (NTRS)
1976-01-01
The Photovoltaic Conversion Program was established to find methods of economically generating enough electrical power to meet future requirements. Activities and progress in the following areas are discussed: silicon-refinement processes; silicon-sheet-growth techniques; encapsulants; manufacturing of off-the-shelf solar arrays; and procurement of semistandardized solar arrays.
Qualitative research and the profound grasp of the obvious.
Hurley, R E
1999-01-01
OBJECTIVE: To discuss the value of promoting coexistent and complementary relationships between qualitative and quantitative research methods as illustrated by presentations made by four respected health services researchers who described their experiences in multi-method projects. DATA SOURCES: Presentations and publications related to the four research projects, which described key substantive and methodological areas that had been addressed with qualitative techniques. PRINCIPAL FINDINGS: Sponsor interest in timely, insightful, and reality-anchored evidence has provided a strong base of support for the incorporation of qualitative methods into major contemporary policy research studies. In addition, many issues may be suitable for study only with qualitative methods because of their complexity, their emergent nature, or because of the need to revisit and reexamine previously untested assumptions. CONCLUSION: Experiences from the four projects, as well as from other recent health services studies with major qualitative components, support the assertion that the interests of sponsors in the policy realm and pressure from them suppress some of the traditional tensions and antagonisms between qualitative and quantitative methods. PMID:10591276
Outlook for coastal plain forests: a subregional report from the Southern Forest Futures Project
Kier Klepzig; Richard Shelfer; Zanethia Choice
2014-01-01
The U.S. Coastal Plain consists of seven sections: the Northern Atlantic, Eastern Atlantic, Peninsular Florida, Southern Gulf, Middle Gulf-East, Middle Gulf-West, and Western Gulf. It covers a large area, consists of a diverse array of habitats, and supports a diverse array of uses. This report presents forecasts from the Southern Forest Futures Project that are...
LIGHTWEIGHT INTEGRATED SOLAR ARRAY AND TRANSCEIVER
2016-09-23
JOHN CARR, CO-PRINCIPAL INVESTIGATOR FOR NASA'S LIGHTWEIGHT INTEGRATED SOLAR ARRAY AND TRANSCEIVER PROJECT, KNEELS TO SHOW HOW ONE OF THE THIN-FILM SIDES OR "PETALS" IN WHICH PHOTO-VOLTAIC CELLS ARE EMBEDDED, IS FOLDED AND STOWED BEFORE LAUNCH. LOOKING ON DURING A DEMONSTRATION AFTER TESTING AT NEXOLVE, ARE LES JOHNSON, LEFT, ALSO CO-PRINCIPAL INVESTIGATOR, AND DARREN BOYD, RIGHT, THE RADIO FREQUENCY LEAD FOR THE PROJECT.
Glyco-Immune Diagnostic Signatures and Therapeutic Targets of Mesothelioma
2015-09-01
Mesothelioma; Glycan Array; Immunoprofiles; Robotic Arrayer 16. SECURITY CLASSIFICATION OF: U 17. LIMITATION OF ABSTRACT: UU 18. NUMBER OF PAGES 19 19a...PROJECT SUMMARY: General Comments: This project involved novel technology in which biochemically synthesized glycans were robotically printed on glass...include 386 glycans and the platform was known as the PGA-400. (Figure 1) A standard robotic technology for printing a large range of
Remotely piloted vehicle: Application of the GRASP analysis method
NASA Technical Reports Server (NTRS)
Andre, W. L.; Morris, J. B.
1981-01-01
The application of General Reliability Analysis Simulation Program (GRASP) to the remotely piloted vehicle (RPV) system is discussed. The model simulates the field operation of the RPV system. By using individual component reliabilities, the overall reliability of the RPV system is determined. The results of the simulations are given in operational days. The model represented is only a basis from which more detailed work could progress. The RPV system in this model is based on preliminary specifications and estimated values. The use of GRASP from basic system definition, to model input, and to model verification is demonstrated.
Tactile Gloves for Autonomous Grasping With the NASA/DARPA Robonaut
NASA Technical Reports Server (NTRS)
Martin, T. B.; Ambrose, R. O.; Diftler, M. A.; Platt, R., Jr.; Butzer, M. J.
2004-01-01
Tactile data from rugged gloves are providing the foundation for developing autonomous grasping skills for the NASA/DARPA Robonaut, a dexterous humanoid robot. These custom gloves compliment the human like dexterity available in the Robonaut hands. Multiple versions of the gloves are discussed, showing a progression in using advanced materials and construction techniques to enhance sensitivity and overall sensor coverage. The force data provided by the gloves can be used to improve dexterous, tool and power grasping primitives. Experiments with the latest gloves focus on the use of tools, specifically a power drill used to approximate an astronaut's torque tool.
Efficient visual grasping alignment for cylinders
NASA Technical Reports Server (NTRS)
Nicewarner, Keith E.; Kelley, Robert B.
1992-01-01
Monocular information from a gripper-mounted camera is used to servo the robot gripper to grasp a cylinder. The fundamental concept for rapid pose estimation is to reduce the amount of information that needs to be processed during each vision update interval. The grasping procedure is divided into four phases: learn, recognition, alignment, and approach. In the learn phase, a cylinder is placed in the gripper and the pose estimate is stored and later used as the servo target. This is performed once as a calibration step. The recognition phase verifies the presence of a cylinder in the camera field of view. An initial pose estimate is computed and uncluttered scan regions are selected. The radius of the cylinder is estimated by moving the robot a fixed distance toward the cylinder and observing the change in the image. The alignment phase processes only the scan regions obtained previously. Rapid pose estimates are used to align the robot with the cylinder at a fixed distance from it. The relative motion of the cylinder is used to generate an extrapolated pose-based trajectory for the robot controller. The approach phase guides the robot gripper to a grasping position. The cylinder can be grasped with a minimal reaction force and torque when only rough global pose information is initially available.
Testing of visual field with virtual reality goggles in manual and visual grasp modes.
Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas
2014-01-01
Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.
Classification of right-hand grasp movement based on EMOTIV Epoc+
NASA Astrophysics Data System (ADS)
Tobing, T. A. M. L.; Prawito, Wijaya, S. K.
2017-07-01
Combinations of BCT elements for right-hand grasp movement have been obtained, providing the average value of their classification accuracy. The aim of this study is to find a suitable combination for best classification accuracy of right-hand grasp movement based on EEG headset, EMOTIV Epoc+. There are three movement classifications: grasping hand, relax, and opening hand. These classifications take advantage of Event-Related Desynchronization (ERD) phenomenon that makes it possible to differ relaxation, imagery, and movement state from each other. The combinations of elements are the usage of Independent Component Analysis (ICA), spectrum analysis by Fast Fourier Transform (FFT), maximum mu and beta power with their frequency as features, and also classifier Probabilistic Neural Network (PNN) and Radial Basis Function (RBF). The average values of classification accuracy are ± 83% for training and ± 57% for testing. To have a better understanding of the signal quality recorded by EMOTIV Epoc+, the result of classification accuracy of left or right-hand grasping movement EEG signal (provided by Physionet) also be given, i.e.± 85% for training and ± 70% for testing. The comparison of accuracy value from each combination, experiment condition, and external EEG data are provided for the purpose of value analysis of classification accuracy.
Efficient visual grasping alignment for cylinders
NASA Technical Reports Server (NTRS)
Nicewarner, Keith E.; Kelley, Robert B.
1991-01-01
Monocular information from a gripper-mounted camera is used to servo the robot gripper to grasp a cylinder. The fundamental concept for rapid pose estimation is to reduce the amount of information that needs to be processed during each vision update interval. The grasping procedure is divided into four phases: learn, recognition, alignment, and approach. In the learn phase, a cylinder is placed in the gripper and the pose estimate is stored and later used as the servo target. This is performed once as a calibration step. The recognition phase verifies the presence of a cylinder in the camera field of view. An initial pose estimate is computed and uncluttered scan regions are selected. The radius of the cylinder is estimated by moving the robot a fixed distance toward the cylinder and observing the change in the image. The alignment phase processes only the scan regions obtained previously. Rapid pose estimates are used to align the robot with the cylinder at a fixed distance from it. The relative motion of the cylinder is used to generate an extrapolated pose-based trajectory for the robot controller. The approach phase guides the robot gripper to a grasping position. The cylinder can be grasped with a minimal reaction force and torque when only rough global pose information is initially available.
Kukke, Sahana N.; Curatalo, Lindsey A.; de Campos, Ana Carolina; Hallett, Mark; Alter, Katharine E.; Damiano, Diane L.
2015-01-01
Functional reaching is impaired in dystonia. Here, we analyze upper extremity kinematics to quantify timing and coordination abnormalities during unimanual reach-to-grasp movements in individuals with childhood-onset unilateral wrist dystonia. Kinematics were measured during movements of both upper limbs in a patient group (n = 11, age = 17.5 ± 5 years), and a typically developing control group (n = 9, age = 16.6 ± 5 years). Hand aperture was computed to study the coordination of reach and grasp. Time-varying joint synergies within one upper limb were calculated using a novel technique based on principal component analysis to study intra-limb coordination. In the non-dominant arm, results indicate reduced coordination between reach and grasp in patients who could not lift the grasped object compared to those who could lift it. Lifters exhibit incoordination in distal upper extremity joints later in the movement and non-lifters lacked coordination throughout the movement and in the whole upper limb. The amount of atypical coordination correlates with dystonia severity in patients. Reduced coordination during movement may reflect deficits in the execution of simultaneous movements, motor planning, or muscle activation. Rehabilitation efforts can focus on particular time points when kinematic patterns deviate abnormally to improve functional reaching in individuals with childhood-onset dystonia. PMID:26208359
Exploration of Hand Grasp Patterns Elicitable Through Non-Invasive Proximal Nerve Stimulation.
Shin, Henry; Watkins, Zach; Hu, Xiaogang
2017-11-29
Various neurological conditions, such as stroke or spinal cord injury, result in an impaired control of the hand. One method of restoring this impairment is through functional electrical stimulation (FES). However, traditional FES techniques often lead to quick fatigue and unnatural ballistic movements. In this study, we sought to explore the capabilities of a non-invasive proximal nerve stimulation technique in eliciting various hand grasp patterns. The ulnar and median nerves proximal to the elbow joint were activated transcutanously using a programmable stimulator, and the resultant finger flexion joint angles were recorded using a motion capture system. The individual finger motions averaged across the three joints were analyzed using a cluster analysis, in order to classify the different hand grasp patterns. With low current intensity (<5 mA and 100 µs pulse width) stimulation, our results show that all of our subjects demonstrated a variety of consistent hand grasp patterns including single finger movement and coordinated multi-finger movements. This study provides initial evidence on the feasibility of a proximal nerve stimulation technique in controlling a variety of finger movements and grasp patterns. Our approach could also be developed into a rehabilitative/assistive tool that can result in flexible movements of the fingers.
Kukke, Sahana N; Curatalo, Lindsey A; de Campos, Ana Carolina; Hallett, Mark; Alter, Katharine E; Damiano, Diane L
2016-05-01
Functional reaching is impaired in dystonia. Here, we analyze upper extremity kinematics to quantify timing and coordination abnormalities during unimanual reach-to-grasp movements in individuals with childhood-onset unilateral wrist dystonia. Kinematics were measured during movements of both upper limbs in a patient group ( n = 11, age = 17.5 ±5 years), and a typically developing control group ( n = 9, age = 16.6 ±5 years). Hand aperture was computed to study the coordination of reach and grasp. Time-varying joint synergies within one upper limb were calculated using a novel technique based on principal component analysis to study intra-limb coordination. In the non-dominant arm, results indicate reduced coordination between reach and grasp in patients who could not lift the grasped object compared to those who could lift it. Lifters exhibit incoordination in distal upper extremity joints later in the movement and non-lifters lacked coordination throughout the movement and in the whole upper limb. The amount of atypical coordination correlates with dystonia severity in patients. Reduced coordination during movement may reflect deficits in the execution of simultaneous movements, motor planning, or muscle activation. Rehabilitation efforts can focus on particular time points when kinematic patterns deviate abnormally to improve functional reaching in individuals with childhood-onset dystonia.
Neuromimetic Event-Based Detection for Closed-Loop Tactile Feedback Control of Upper Limb Prostheses
Osborn, Luke; Kaliki, Rahul; Soares, Alcimar; Thakor, Nitish
2016-01-01
Upper limb amputees lack the valuable tactile sensing that helps provide context about the surrounding environment. Here we utilize tactile information to provide active touch feedback to a prosthetic hand. First, we developed fingertip tactile sensors for producing biomimetic spiking responses for monitoring contact, release, and slip of an object grasped by a prosthetic hand. We convert the sensor output into pulses, mimicking the rapid and slowly adapting spiking responses of receptor afferents found in the human body. Second, we designed and implemented two neuromimetic event-based algorithms, Compliant Grasping and Slip Prevention, on a prosthesis to create a local closed-loop tactile feedback control system (i.e. tactile information is sent to the prosthesis). Grasping experiments were designed to assess the benefit of this biologically inspired neuromimetic tactile feedback to a prosthesis. Results from able-bodied and amputee subjects show the average number of objects that broke or slipped during grasping decreased by over 50% and the average time to complete a grasping task decreased by at least 10% for most trials when comparing neuromimetic tactile feedback with no feedback on a prosthesis. Our neuromimetic method of closed-loop tactile sensing is a novel approach to improving the function of upper limb prostheses. PMID:27777640
The Effects of Linear Microphone Array Changes on Computed Sound Exposure Level Footprints
NASA Technical Reports Server (NTRS)
Mueller, Arnold W.; Wilson, Mark R.
1997-01-01
Airport land planning commissions often are faced with determining how much area around an airport is affected by the sound exposure levels (SELS) associated with helicopter operations. This paper presents a study of the effects changing the size and composition of a microphone array has on the computed SEL contour (ground footprint) areas used by such commissions. Descent flight acoustic data measured by a fifteen microphone array were reprocessed for five different combinations of microphones within this array. This resulted in data for six different arrays for which SEL contours were computed. The fifteen microphone array was defined as the 'baseline' array since it contained the greatest amount of data. The computations used a newly developed technique, the Acoustic Re-propagation Technique (ART), which uses parts of the NASA noise prediction program ROTONET. After the areas of the SEL contours were calculated the differences between the areas were determined. The area differences for the six arrays are presented that show a five and a three microphone array (with spacing typical of that required by the FAA FAR Part 36 noise certification procedure) compare well with the fifteen microphone array. All data were obtained from a database resulting from a joint project conducted by NASA and U.S. Army researchers at Langley and Ames Research Centers. A brief description of the joint project test design, microphone array set-up, and data reduction methodology associated with the database are discussed.
Development of optics with micro-LED arrays for improved opto-electronic neural stimulation
NASA Astrophysics Data System (ADS)
Chaudet, Lionel; Neil, Mark; Degenaar, Patrick; Mehran, Kamyar; Berlinguer-Palmini, Rolando; Corbet, Brian; Maaskant, Pleun; Rogerson, David; Lanigan, Peter; Bamberg, Ernst; Roska, Botond
2013-03-01
The breakthrough discovery of a nanoscale optically gated ion channel protein, Channelrhodopsin 2 (ChR2), and its combination with a genetically expressed ion pump, Halorhodopsin, allowed the direct stimulation and inhibition of individual action potentials with light alone. This work reports developments of ultra-bright elec tronically controlled optical array sources with enhanced light gated ion channels and pumps for use in systems to further our understanding of both brain and visual function. This work is undertaken as part of the European project, OptoNeuro. Micro-LED arrays permit spatio-temporal control of neuron stimulation on sub-millisecond timescales. However they are disadvantaged by their broad spatial light emission distribution and low fill factor. We present the design and implementation of a projection and micro-optics system for use with a micro-LED array consisting of a 16x16 matrix of 25 μm diameter micro-LEDs with 150 μm centre-to-centre spacing and an emission spectrum centred at 470 nm overlapping the peak sensitivity of ChR2 and its testing on biological samples. The projection system images the micro-LED array onto micro-optics to improve the fill-factor from ~2% to more than 78% by capturing a larger fraction of the LED emission and directing it correctly to the sample plane. This approach allows low fill factor arrays to be used effectively, which in turn has benefits in terms of thermal management and electrical drive from CMOS backplane electronics. The entire projection system is integrated into a microscope prototype to provide stimulation spots at the same size as the neuron cell body (μ10 pm).
SKS splitting results in central Italy and Dinaric region inside the AlpArray-CASE project
NASA Astrophysics Data System (ADS)
Salimbeni, S.; Prevolnik, S.; Pondrelli, S.; Molinari, I.; Stipcevic, J.; Kissling, E.; Šipka, V.; Herak, M.
2017-12-01
In the framework of the AlpArray project (AlpArray Seismic Network, 2015), the complementary "Central Adriatic Seismic Experiment" (CASE; AlpArray Seismic Network, 2016) was established as collaboration between ETH Zürich, University of Zagreb, INGV and Republic Hydrometeorological Service of Republic of Srpska. The CASE project consists of 9 temporary stations, installed in October 2016, located in Bosnia and Herzegovina, Croatia and Italy. Temporary broadband seismic stations, with the permanent stations present in the region shared by the Croatian Seismological Service and INGV, make an almost continuous transect cutting the Central-Southern Appenines, the central Adriatic region, central External Dinarides and finishing at the eastern margin of the Internal Dinarides. The presence of the the Apenninic and Dinarides slabs, verging in opposite directions and plunging along the opposite sides of the Adriatic plate, make this area a peculiar spot to understand the complex dynamic of the region. Various tomographic images (e.g. Bijwaard and Spakman, 2000; Piromallo and Morelli, 2003) shows not continuous slabs under the Appenines and the Dinarides, suggesting the presence of slab-gaps right beneath the region covered by the CASE experiment. Here we present the preliminary results of the SKS splitting analysis performed on the data recorded by the temporary and permanent seismic stations included in the CASE project. The new results, in combination with previous interpretation, will provide clues about how Northern and Southern Apennines are connected at depth, how the slab rollback of the Apennines thrust belt acted and if and how the Apennines are in relation with the Dinaric region. Together with the measurements from previous studies and from the AlpArray project, our new data will support the mapping of the seismic anisotropy deformation pattern from Western Alps to Pannonian region.
Barz, F; Livi, A; Lanzilotto, M; Maranesi, M; Bonini, L; Paul, O; Ruther, P
2017-06-01
Application-specific designs of electrode arrays offer an improved effectiveness for providing access to targeted brain regions in neuroscientific research and brain machine interfaces. The simultaneous and stable recording of neuronal ensembles is the main goal in the design of advanced neural interfaces. Here, we describe the development and assembly of highly customizable 3D microelectrode arrays and demonstrate their recording performance in chronic applications in non-human primates. System assembly relies on a microfabricated stacking component that is combined with Michigan-style silicon-based electrode arrays interfacing highly flexible polyimide cables. Based on the novel stacking component, the lead time for implementing prototypes with altered electrode pitches is minimal. Once the fabrication and assembly accuracy of the stacked probes have been characterized, their recording performance is assessed during in vivo chronic experiments in awake rhesus macaques (Macaca mulatta) trained to execute reaching-grasping motor tasks. Using a single set of fabrication tools, we implemented three variants of the stacking component for electrode distances of 250, 300 and 350 µm in the stacking direction. We assembled neural probes with up to 96 channels and an electrode density of 98 electrodes mm -2 . Furthermore, we demonstrate that the shank alignment is accurate to a few µm at an angular alignment better than 1°. Three 64-channel probes were chronically implanted in two monkeys providing single-unit activity on more than 60% of all channels and excellent recording stability. Histological tissue sections, obtained 52 d after implantation from one of the monkeys, showed minimal tissue damage, in accordance with the high quality and stability of the recorded neural activity. The versatility of our fabrication and assembly approach should significantly support the development of ideal interface geometries for a broad spectrum of applications. With the demonstrated performance, these probes are suitable for both semi-chronic and chronic applications.
NASA Astrophysics Data System (ADS)
Barz, F.; Livi, A.; Lanzilotto, M.; Maranesi, M.; Bonini, L.; Paul, O.; Ruther, P.
2017-06-01
Objective. Application-specific designs of electrode arrays offer an improved effectiveness for providing access to targeted brain regions in neuroscientific research and brain machine interfaces. The simultaneous and stable recording of neuronal ensembles is the main goal in the design of advanced neural interfaces. Here, we describe the development and assembly of highly customizable 3D microelectrode arrays and demonstrate their recording performance in chronic applications in non-human primates. Approach. System assembly relies on a microfabricated stacking component that is combined with Michigan-style silicon-based electrode arrays interfacing highly flexible polyimide cables. Based on the novel stacking component, the lead time for implementing prototypes with altered electrode pitches is minimal. Once the fabrication and assembly accuracy of the stacked probes have been characterized, their recording performance is assessed during in vivo chronic experiments in awake rhesus macaques (Macaca mulatta) trained to execute reaching-grasping motor tasks. Main results. Using a single set of fabrication tools, we implemented three variants of the stacking component for electrode distances of 250, 300 and 350 µm in the stacking direction. We assembled neural probes with up to 96 channels and an electrode density of 98 electrodes mm-2. Furthermore, we demonstrate that the shank alignment is accurate to a few µm at an angular alignment better than 1°. Three 64-channel probes were chronically implanted in two monkeys providing single-unit activity on more than 60% of all channels and excellent recording stability. Histological tissue sections, obtained 52 d after implantation from one of the monkeys, showed minimal tissue damage, in accordance with the high quality and stability of the recorded neural activity. Significance. The versatility of our fabrication and assembly approach should significantly support the development of ideal interface geometries for a broad spectrum of applications. With the demonstrated performance, these probes are suitable for both semi-chronic and chronic applications.
Simplification of Visual Rendering in Simulated Prosthetic Vision Facilitates Navigation.
Vergnieux, Victor; Macé, Marc J-M; Jouffrais, Christophe
2017-09-01
Visual neuroprostheses are still limited and simulated prosthetic vision (SPV) is used to evaluate potential and forthcoming functionality of these implants. SPV has been used to evaluate the minimum requirement on visual neuroprosthetic characteristics to restore various functions such as reading, objects and face recognition, object grasping, etc. Some of these studies focused on obstacle avoidance but only a few investigated orientation or navigation abilities with prosthetic vision. The resolution of current arrays of electrodes is not sufficient to allow navigation tasks without additional processing of the visual input. In this study, we simulated a low resolution array (15 × 18 electrodes, similar to a forthcoming generation of arrays) and evaluated the navigation abilities restored when visual information was processed with various computer vision algorithms to enhance the visual rendering. Three main visual rendering strategies were compared to a control rendering in a wayfinding task within an unknown environment. The control rendering corresponded to a resizing of the original image onto the electrode array size, according to the average brightness of the pixels. In the first rendering strategy, vision distance was limited to 3, 6, or 9 m, respectively. In the second strategy, the rendering was not based on the brightness of the image pixels, but on the distance between the user and the elements in the field of view. In the last rendering strategy, only the edges of the environments were displayed, similar to a wireframe rendering. All the tested renderings, except the 3 m limitation of the viewing distance, improved navigation performance and decreased cognitive load. Interestingly, the distance-based and wireframe renderings also improved the cognitive mapping of the unknown environment. These results show that low resolution implants are usable for wayfinding if specific computer vision algorithms are used to select and display appropriate information regarding the environment. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Rule, Michael E.; Vargas-Irwin, Carlos; Donoghue, John P.; Truccolo, Wilson
2015-01-01
Understanding the sources of variability in single-neuron spiking responses is an important open problem for the theory of neural coding. This variability is thought to result primarily from spontaneous collective dynamics in neuronal networks. Here, we investigate how well collective dynamics reflected in motor cortex local field potentials (LFPs) can account for spiking variability during motor behavior. Neural activity was recorded via microelectrode arrays implanted in ventral and dorsal premotor and primary motor cortices of non-human primates performing naturalistic 3-D reaching and grasping actions. Point process models were used to quantify how well LFP features accounted for spiking variability not explained by the measured 3-D reach and grasp kinematics. LFP features included the instantaneous magnitude, phase and analytic-signal components of narrow band-pass filtered (δ,θ,α,β) LFPs, and analytic signal and amplitude envelope features in higher-frequency bands. Multiband LFP features predicted single-neuron spiking (1ms resolution) with substantial accuracy as assessed via ROC analysis. Notably, however, models including both LFP and kinematics features displayed marginal improvement over kinematics-only models. Furthermore, the small predictive information added by LFP features to kinematic models was redundant to information available in fast-timescale (<100 ms) spiking history. Overall, information in multiband LFP features, although predictive of single-neuron spiking during movement execution, was redundant to information available in movement parameters and spiking history. Our findings suggest that, during movement execution, collective dynamics reflected in motor cortex LFPs primarily relate to sensorimotor processes directly controlling movement output, adding little explanatory power to variability not accounted by movement parameters. PMID:26157365
Imaging with New Classic and Vision at the NPOI
NASA Astrophysics Data System (ADS)
Jorgensen, Anders
2018-04-01
The Navy Precision Optical Interferometer (NPOI) is unique among interferometric observatories for its ability to position telescopes in an equally-spaced array configuration. This configuration is optimal for interferometric imaging because it allows the use of bootstrapping to track fringes on long baselines with signal-to-noise ratio less than one. When combined with coherent integration techniques this can produce visibilities with acceptable SNR on baselines long enough to resolve features on the surfaces of stars. The stellar surface imaging project at NPOI combines the bootstrapping array configuration of the NPOI array, real-time fringe tracking, baseline- and wavelength bootstrapping with Earth rotation to provide dense coverage in the UV plane at a wide range of spatial frequencies. In this presentation, we provide an overview of the project and an update of the latest status and results from the project.
Extracting Objects for Aerial Manipulation on UAVs Using Low Cost Stereo Sensors
Ramon Soria, Pablo; Bevec, Robert; Arrue, Begoña C.; Ude, Aleš; Ollero, Aníbal
2016-01-01
Giving unmanned aerial vehicles (UAVs) the possibility to manipulate objects vastly extends the range of possible applications. This applies to rotary wing UAVs in particular, where their capability of hovering enables a suitable position for in-flight manipulation. Their manipulation skills must be suitable for primarily natural, partially known environments, where UAVs mostly operate. We have developed an on-board object extraction method that calculates information necessary for autonomous grasping of objects, without the need to provide the model of the object’s shape. A local map of the work-zone is generated using depth information, where object candidates are extracted by detecting areas different to our floor model. Their image projections are then evaluated using support vector machine (SVM) classification to recognize specific objects or reject bad candidates. Our method builds a sparse cloud representation of each object and calculates the object’s centroid and the dominant axis. This information is then passed to a grasping module. Our method works under the assumption that objects are static and not clustered, have visual features and the floor shape of the work-zone area is known. We used low cost cameras for creating depth information that cause noisy point clouds, but our method has proved robust enough to process this data and return accurate results. PMID:27187413
Extracting Objects for Aerial Manipulation on UAVs Using Low Cost Stereo Sensors.
Ramon Soria, Pablo; Bevec, Robert; Arrue, Begoña C; Ude, Aleš; Ollero, Aníbal
2016-05-14
Giving unmanned aerial vehicles (UAVs) the possibility to manipulate objects vastly extends the range of possible applications. This applies to rotary wing UAVs in particular, where their capability of hovering enables a suitable position for in-flight manipulation. Their manipulation skills must be suitable for primarily natural, partially known environments, where UAVs mostly operate. We have developed an on-board object extraction method that calculates information necessary for autonomous grasping of objects, without the need to provide the model of the object's shape. A local map of the work-zone is generated using depth information, where object candidates are extracted by detecting areas different to our floor model. Their image projections are then evaluated using support vector machine (SVM) classification to recognize specific objects or reject bad candidates. Our method builds a sparse cloud representation of each object and calculates the object's centroid and the dominant axis. This information is then passed to a grasping module. Our method works under the assumption that objects are static and not clustered, have visual features and the floor shape of the work-zone area is known. We used low cost cameras for creating depth information that cause noisy point clouds, but our method has proved robust enough to process this data and return accurate results.
Global cortical activity predicts shape of hand during grasping
Agashe, Harshavardhan A.; Paek, Andrew Y.; Zhang, Yuhang; Contreras-Vidal, José L.
2015-01-01
Recent studies show that the amplitude of cortical field potentials is modulated in the time domain by grasping kinematics. However, it is unknown if these low frequency modulations persist and contain enough information to decode grasp kinematics in macro-scale activity measured at the scalp via electroencephalography (EEG). Further, it is unclear as to whether joint angle velocities or movement synergies are the optimal kinematics spaces to decode. In this offline decoding study, we infer from human EEG, hand joint angular velocities as well as synergistic trajectories as subjects perform natural reach-to-grasp movements. Decoding accuracy, measured as the correlation coefficient (r) between the predicted and actual movement kinematics, was r = 0.49 ± 0.02 across 15 hand joints. Across the first three kinematic synergies, decoding accuracies were r = 0.59 ± 0.04, 0.47 ± 0.06, and 0.32 ± 0.05. The spatial-temporal pattern of EEG channel recruitment showed early involvement of contralateral frontal-central scalp areas followed by later activation of central electrodes over primary sensorimotor cortical areas. Information content in EEG about the grasp type peaked at 250 ms after movement onset. The high decoding accuracies in this study are significant not only as evidence for time-domain modulation in macro-scale brain activity, but for the field of brain-machine interfaces as well. Our decoding strategy, which harnesses the neural “symphony” as opposed to local members of the neural ensemble (as in intracranial approaches), may provide a means of extracting information about motor intent for grasping without the need for penetrating electrodes and suggests that it may be soon possible to develop non-invasive neural interfaces for the control of prosthetic limbs. PMID:25914616
May, Zacnicte; Fouad, Karim; Shum-Siu, Alice; Magnuson, David S K
2015-09-15
A rarely explored subject in animal research is the effect of pre-injury variables on behavioral outcome post-SCI. Low reporting of such variables may underlie some discrepancies in findings between laboratories. Particularly, intensive task-specific training before a SCI might be important, considering that sports injuries are one of the leading causes of SCI. Thus, individuals with SCI often underwent rigorous training before their injuries. In the present study, we asked whether training before SCI on a grasping task or a swimming task would influence motor recovery in rats. Swim pre-training impaired recovery of swimming 2 and 4 weeks post-injury. This result fits with the idea of motor learning interference, which posits that learning something new may disrupt learning of a new task; in this case, learning strategies to compensate for functional loss after SCI. In contrast to swimming, grasp pre-training did not influence grasping ability after SCI at any time point. However, grasp pre-trained rats attempted to grasp more times than untrained rats in the first 4 weeks post-injury. Also, lesion volume of grasp pre-trained rats was greater than that of untrained rats, a finding which may be related to stress or activity. The increased participation in rehabilitative training of the pre-trained rats in the early weeks post-injury may have potentiated spontaneous plasticity in the spinal cord and counteracted the deleterious effect of interference and bigger lesions. Thus, our findings suggest that pre-training plays a significant role in recovery after CNS damage and needs to be carefully controlled for. Copyright © 2015 Elsevier B.V. All rights reserved.
Chen, Juan; Sperandio, Irene; Goodale, Melvyn Alan
2018-03-19
Our brain integrates information from multiple modalities in the control of behavior. When information from one sensory source is compromised, information from another source can compensate for the loss. What is not clear is whether the nature of this multisensory integration and the re-weighting of different sources of sensory information are the same across different control systems. Here, we investigated whether proprioceptive distance information (position sense of body parts) can compensate for the loss of visual distance cues that support size constancy in perception (mediated by the ventral visual stream) [1, 2] versus size constancy in grasping (mediated by the dorsal visual stream) [3-6], in which the real-world size of an object is computed despite changes in viewing distance. We found that there was perfect size constancy in both perception and grasping in a full-viewing condition (lights on, binocular viewing) and that size constancy in both tasks was dramatically disrupted in the restricted-viewing condition (lights off; monocular viewing of the same but luminescent object through a 1-mm pinhole). Importantly, in the restricted-viewing condition, proprioceptive cues about viewing distance originating from the non-grasping limb (experiment 1) or the inclination of the torso and/or the elbow angle of the grasping limb (experiment 2) compensated for the loss of visual distance cues to enable a complete restoration of size constancy in grasping but only a modest improvement of size constancy in perception. This suggests that the weighting of different sources of sensory information varies as a function of the control system being used. Copyright © 2018 Elsevier Ltd. All rights reserved.
Downey, John E; Weiss, Jeffrey M; Muelling, Katharina; Venkatraman, Arun; Valois, Jean-Sebastien; Hebert, Martial; Bagnell, J Andrew; Schwartz, Andrew B; Collinger, Jennifer L
2016-03-18
Recent studies have shown that brain-machine interfaces (BMIs) offer great potential for restoring upper limb function. However, grasping objects is a complicated task and the signals extracted from the brain may not always be capable of driving these movements reliably. Vision-guided robotic assistance is one possible way to improve BMI performance. We describe a method of shared control where the user controls a prosthetic arm using a BMI and receives assistance with positioning the hand when it approaches an object. Two human subjects with tetraplegia used a robotic arm to complete object transport tasks with and without shared control. The shared control system was designed to provide a balance between BMI-derived intention and computer assistance. An autonomous robotic grasping system identified and tracked objects and defined stable grasp positions for these objects. The system identified when the user intended to interact with an object based on the BMI-controlled movements of the robotic arm. Using shared control, BMI controlled movements and autonomous grasping commands were blended to ensure secure grasps. Both subjects were more successful on object transfer tasks when using shared control compared to BMI control alone. Movements made using shared control were more accurate, more efficient, and less difficult. One participant attempted a task with multiple objects and successfully lifted one of two closely spaced objects in 92 % of trials, demonstrating the potential for users to accurately execute their intention while using shared control. Integration of BMI control with vision-guided robotic assistance led to improved performance on object transfer tasks. Providing assistance while maintaining generalizability will make BMI systems more attractive to potential users. NCT01364480 and NCT01894802 .
Development of novel force-limiting grasping forceps with a simple mechanism.
Sakaguchi, Yasuto; Sato, Toshihiko; Yutaka, Yojiro; Muranishi, Yusuke; Komatsu, Teruya; Yoshizawa, Akihiko; Nakajima, Naoki; Nakamura, Tatsuo; Date, Hiroshi
2018-06-06
In endoscopic surgery, fragile tissues may be damaged by the application of excessive force. Thus, we developed novel endoscopic forceps with a simple force-limiting mechanism. The novel forceps were constructed with a leaf spring, and the spring thickness determines grasping pressure. We established an evaluation system (maximum score is 11 points) for lung tissue damage leading to complications. We tested the conventional forceps (186.8 kPa) and 3 novel spring forceps with the following thicknesses: 1.3 mm (53.0 kPa), 2.2 mm (187.7 kPa) and 2.8 mm (369.2 kPa). After grasping, peripheral canine lung tissues were microscopically examined for acute- and late-phase damages. In the acute phase (20 sites), the novel forceps caused capillary congestion and haemorrhage in the subpleural tissue, whereas the conventional forceps caused deep tissue and pleural damages. In the late phase (30 sites), both forceps caused fibroblast formation and interstitial thickening, which progressed to the deeper tissues as grasping pressure increased. In the acute phase, the median scores were 2.0 and 6.0 for the novel and conventional forceps, respectively (P = 0.003). In the late phase, the median scores were 2.0, 2.5 and 5.0 for 1.3-, 2.2- and 2.8-mm thick forceps, respectively, and 5.0 for the conventional forceps (P < 0.001). In both phases, the novel forceps with grasping pressure set below 187.7 kPa (2.2 mm) caused significantly less lung tissue damage than the conventional forceps. The novel endoscopic forceps are able to regulate the tissue-grasping pressure and induce less damage in lung tissues than conventional forceps.
Bimanual reach to grasp movements after cervical spinal cord injury.
Britten, Laura; Coats, Rachel; Ichiyama, Ronaldo; Raza, Wajid; Jamil, Firas; Astill, Sarah
2017-01-01
Injury to the cervical spinal cord results in bilateral deficits in arm/hand function reducing functional independence and quality of life. To date little research has been undertaken to investigate control strategies of arm/hand movements following cervical spinal cord injury (cSCI). This study aimed to investigate unimanual and bimanual coordination in patients with acute cSCI using 3D kinematic analysis as they performed naturalistic reach to grasp actions with one hand, or with both hands together (symmetrical task), and compare this to the movement patterns of uninjured younger and older adults. Eighteen adults with a cSCI (mean 61.61 years) with lesions at C4-C8, with an American Spinal Injury Association (ASIA) grade B to D and 16 uninjured younger adults (mean 23.68 years) and sixteen uninjured older adults (mean 70.92 years) were recruited. Participants with a cSCI produced reach-to-grasp actions which took longer, were slower, and had longer deceleration phases than uninjured participants. These differences were exacerbated during bimanual reach-to-grasp tasks. Maximal grasp aperture was no different between groups, but reached earlier by people with cSCI. Participants with a cSCI were less synchronous than younger and older adults but all groups used the deceleration phase for error correction to end the movement in a synchronous fashion. Overall, this study suggests that after cSCI a level of bimanual coordination is retained. While there seems to be a greater reliance on feedback to produce both the reach to grasp, we observed minimal disruption of the more impaired limb on the less impaired limb. This suggests that bimanual movements should be integrated into therapy.
Bimanual reach to grasp movements after cervical spinal cord injury
Raza, Wajid; Jamil, Firas
2017-01-01
Injury to the cervical spinal cord results in bilateral deficits in arm/hand function reducing functional independence and quality of life. To date little research has been undertaken to investigate control strategies of arm/hand movements following cervical spinal cord injury (cSCI). This study aimed to investigate unimanual and bimanual coordination in patients with acute cSCI using 3D kinematic analysis as they performed naturalistic reach to grasp actions with one hand, or with both hands together (symmetrical task), and compare this to the movement patterns of uninjured younger and older adults. Eighteen adults with a cSCI (mean 61.61 years) with lesions at C4-C8, with an American Spinal Injury Association (ASIA) grade B to D and 16 uninjured younger adults (mean 23.68 years) and sixteen uninjured older adults (mean 70.92 years) were recruited. Participants with a cSCI produced reach-to-grasp actions which took longer, were slower, and had longer deceleration phases than uninjured participants. These differences were exacerbated during bimanual reach-to-grasp tasks. Maximal grasp aperture was no different between groups, but reached earlier by people with cSCI. Participants with a cSCI were less synchronous than younger and older adults but all groups used the deceleration phase for error correction to end the movement in a synchronous fashion. Overall, this study suggests that after cSCI a level of bimanual coordination is retained. While there seems to be a greater reliance on feedback to produce both the reach to grasp, we observed minimal disruption of the more impaired limb on the less impaired limb. This suggests that bimanual movements should be integrated into therapy. PMID:28384247
Fixation Biases towards the Index Finger in Almost-Natural Grasping
Voudouris, Dimitris; Smeets, Jeroen B. J.; Brenner, Eli
2016-01-01
We use visual information to guide our grasping movements. When grasping an object with a precision grip, the two digits need to reach two different positions more or less simultaneously, but the eyes can only be directed to one position at a time. Several studies that have examined eye movements in grasping have found that people tend to direct their gaze near where their index finger will contact the object. Here we aimed at better understanding why people do so by asking participants to lift an object off a horizontal surface. They were to grasp the object with a precision grip while movements of their hand, eye and head were recorded. We confirmed that people tend to look closer to positions that a digit needs to reach more accurately. Moreover, we show that where they look as they reach for the object depends on where they were looking before, presumably because they try to minimize the time during which the eyes are moving so fast that no new visual information is acquired. Most importantly, we confirmed that people have a bias to direct gaze towards the index finger’s contact point rather than towards that of the thumb. In our study, this cannot be explained by the index finger contacting the object before the thumb. Instead, it appears to be because the index finger moves to a position that is hidden behind the object that is grasped, probably making this the place at which one is most likely to encounter unexpected problems that would benefit from visual guidance. However, this cannot explain the bias that was found in previous studies, where neither contact point was hidden, so it cannot be the only explanation for the bias. PMID:26766551
Effects of accuracy constraints on reach-to-grasp movements in cerebellar patients.
Rand, M K; Shimansky, Y; Stelmach, G E; Bracha, V; Bloedel, J R
2000-11-01
Reach-to-grasp movements of patients with pathology restricted to the cerebellum were compared with those of normal controls. Two types of paradigms with different accuracy constraints were used to examine whether cerebellar impairment disrupts the stereotypic relationship between arm transport and grip aperture and whether the variability of this relationship is altered when greater accuracy is required. The movements were made to either a vertical dowel or to a cross bar of a small cross. All subjects were asked to reach for either target at a fast but comfortable speed, grasp the object between the index finger and thumb, and lift it a short distance off the table. In terms of the relationship between arm transport and grip aperture, the control subjects showed a high consistency in grip aperture and wrist velocity profiles from trial to trial for movements to both the dowel and the cross. The relationship between the maximum velocity of the wrist and the time at which grip aperture was maximal during the reach was highly consistent throughout the experiment. In contrast, the time of maximum grip aperture and maximum wrist velocity of the cerebellar patients was quite variable from trial to trial, and the relationship of these measurements also varied considerably. These abnormalities were present regardless of the accuracy requirement. In addition, the cerebellar patients required a significantly longer time to grasp and lift the objects than the control subjects. Furthermore, the patients exhibited a greater grip aperture during reach than the controls. These data indicate that the cerebellum contributes substantially to the coordination of movements required to perform reach-to-grasp movements. Specifically, the cerebellum is critical for executing this behavior with a consistent, well-timed relationship between the transport and grasp components. This contribution is apparent even when accuracy demands are minimal.
Cheng, Kenneth C; McKay, Sandra M; King, Emily C; Maki, Brian E
2012-11-01
Rapid reach-to-grasp reactions are a prevalent response to sudden loss of balance and play an important role in preventing falls. A previous study indicated that young adults are able to guide functionally effective grasping reactions using visuospatial information (VSI) stored in working memory. The present study addressed whether healthy older adults are also able to use "stored" VSI in this manner or are more dependent on "online" visual control. Liquid-crystal goggles were used to force reliance on either stored or online VSI while reaching to grasp a small handhold in response to unpredictable platform perturbations. A motor-driven device varied the handhold location unpredictably for each trial. Twelve healthy older adults (65-79 years) were compared with 12 young adults (19-29 years) tested in a previous study. Reach-to-grasp reactions were slower and more variable in older adults, regardless of the nature of the available VSI. When forced to rely on stored VSI, both age groups showed a reduction in reach accuracy; however, a tendency to undershoot the handhold was exacerbated in the older adults. Forced reliance on online VSI led to similar delays in both age groups; however, the older adults were more likely to reach with the "wrong" limb (contralateral to the handhold) and/or raise both arms initially (possibly to "buy" more time for final limb selection). Situations that force the central nervous system to rely on either stored or online VSI tend to exacerbate age-related reductions in speed and accuracy of reach-to-grasp balance-recovery reactions. Further work is needed to determine if this increases risk of falling in daily life.
Brazilian Decimetric Array (BDA) project - Phase II
NASA Astrophysics Data System (ADS)
Faria, C.; Stephany, S.; Sawant, H. S.; Cecatto, J. R.; Fernandes, F. C. R.
2010-02-01
The configuration of the second phase of the Brazilian Decimetric Array (BDA), installed at Cachoeira Paulista, Brazil (Longitude 45° 0‧ 20″ W and Latitude 22° 41‧ 19″ S), is a T-shaped array where 21 antennas are being added to existing 5 antennas of the first phase. In the third phase, in each arm of the T array, four more antennas will be added and baselines will be increased to 2.5 × 1.25 km in east-west and south directions, respectively. The antennas will be equally spaced at the distances of 250 meters from the central antenna of the T-array. Also, the frequency range will be increased to 1.2-1.7, 2.8 and 5.6 GHz. The Second phase of the BDA should be operational by the middle of 2010 and will operate in the frequency range of (1.2-1.7) GHz for solar and non solar observations. Here, we present the characteristics of the second phase of the BDA project, details of the array configuration, the u-v coverage, the synthesized beam obtained for the proposed configuration.
Plenoptic projection fluorescence tomography.
Iglesias, Ignacio; Ripoll, Jorge
2014-09-22
A new method to obtain the three-dimensional localization of fluorochrome distributions in micrometric samples is presented. It uses a microlens array coupled to the image port of a standard microscope to obtain tomographic data by a filtered back-projection algorithm. Scanning of the microlens array is proposed to obtain a dense data set for reconstruction. Simulation and experimental results are shown and the implications of this approach in fast 3D imaging are discussed.
Proposed biomimetic molecular sensor array for astrobiology applications
NASA Astrophysics Data System (ADS)
Cullen, D. C.; Grant, W. D.; Piletsky, S.; Sims, M. R.
2001-08-01
A key objective of future astrobiology lander missions, e.g. to Mars and Europa, is the detection of biomarkers - molecules whose presence indicates the existence of either current or extinct life. To address limitations of current analytical methods for biomarker detection, we describe the methodology of a new project for demonstration of a robust molecular-recognition sensor array for astrobiology biomarkers. The sensor array will be realised by assembling components that have been demonstrated individually in previous or current research projects. The major components are (1) robust artificial molecular receptors comprised of molecular imprinted polymer (MIP) recognition systems and (2) a sensor array comprised of both optical and electrochemical sensor elements. These components will be integrated together using ink-jet printing technology coupled with in situ photo-polymerisation of MIPs. For demonstration, four model biomarkers are chosen as targets and represent various classes of potential biomarkers. Objectives of the proposed work include (1) demonstration of practical proof-of-concept, (2) identify areas for further development and (3) provide performance and design data for follow-up projects leading to astrobiology missions.
Laser diode arrays for naval reconnaissance
NASA Astrophysics Data System (ADS)
Holloway, John H., Jr.; Crosby, Frank J.; Petee, Danny A.; Suiter, Harold R.; Witherspoon, Ned H.
2003-09-01
The Airborne Littoral Reconnaissance Technologies (ALRT) Project has demonstrated a nighttime operational minefield detection capability using commercial off-the-shelf high-power Laser Diode Arrays (LDAs). Historically, optical aerial detection of minefields has primarily been limited to daytime operations but LDAs promise compact and efficient lighting to allow for enhanced reconnaissance operations for future mine detection systems. When combined with high-resolution intensified imaging systems, LDAs can illuminate otherwise unseen areas. Future wavelength options will open the way for active multispectral imaging with LDAs. The Coastal Systems Station working for the Office of Naval Research on the ALRT project has designed, developed, integrated, and tested both prototype and commercial arrays from a Cessna airborne platform. Detailed test results show the ability to detect several targets of interest in a variety of background conditions. Initial testing of the prototype arrays, reported on last year, was completed and further investigations of the commercial versions were performed. Polarization-state detection studies were performed, and advantageous properties of the source-target-sensor geometry noted. Current project plans are to expand the field-of-view coverage for Naval exercises in the summer of 2003. This paper describes the test collection, data library products, array information, on-going test analysis results, and future planned testing of the LDAs.
Liarokapis, Minas V; Artemiadis, Panagiotis K; Kyriakopoulos, Kostas J; Manolakos, Elias S
2013-09-01
A learning scheme based on random forests is used to discriminate between different reach to grasp movements in 3-D space, based on the myoelectric activity of human muscles of the upper-arm and the forearm. Task specificity for motion decoding is introduced in two different levels: Subspace to move toward and object to be grasped. The discrimination between the different reach to grasp strategies is accomplished with machine learning techniques for classification. The classification decision is then used in order to trigger an EMG-based task-specific motion decoding model. Task specific models manage to outperform "general" models providing better estimation accuracy. Thus, the proposed scheme takes advantage of a framework incorporating both a classifier and a regressor that cooperate advantageously in order to split the task space. The proposed learning scheme can be easily used to a series of EMG-based interfaces that must operate in real time, providing data-driven capabilities for multiclass problems, that occur in everyday life complex environments.
Development of a parametric kinematic model of the human hand and a novel robotic exoskeleton.
Burton, T M W; Vaidyanathan, R; Burgess, S C; Turton, A J; Melhuish, C
2011-01-01
This paper reports the integration of a kinematic model of the human hand during cylindrical grasping, with specific focus on the accurate mapping of thumb movement during grasping motions, and a novel, multi-degree-of-freedom assistive exoskeleton mechanism based on this model. The model includes thumb maximum hyper-extension for grasping large objects (~> 50 mm). The exoskeleton includes a novel four-bar mechanism designed to reproduce natural thumb opposition and a novel synchro-motion pulley mechanism for coordinated finger motion. A computer aided design environment is used to allow the exoskeleton to be rapidly customized to the hand dimensions of a specific patient. Trials comparing the kinematic model to observed data of hand movement show the model to be capable of mapping thumb and finger joint flexion angles during grasping motions. Simulations show the exoskeleton to be capable of reproducing the complex motion of the thumb to oppose the fingers during cylindrical and pinch grip motions. © 2011 IEEE
Sensorized toys for measuring manipulation capabilities of infants at home.
Passetti, Giovanni; Cecchi, Francesca; Baldoli, Ilaria; Sgandurra, Giuseppina; Beani, Elena; Cioni, Giovanni; Laschi, Cecilia; Dario, Paolo
2015-01-01
Preterm infants, i.e. babies born after a gestation period shorter than 37 weeks, spend less time exploring objects. The quantitative measurement of grasping actions and forces in infants can give insights on their typical or atypical motor development. The aim of this work was to test a new tool, a kit of sensorized toys, to longitudinally measure, monitor and promote preterm infants manipulation capabilities with a purposive training in an ecological environment. This study presents preliminary analysis of grasping activity. Three preterm infants performed 4 weeks of daily training at home. Sensorized toys with embedded pressure sensors were used as part of the training to allow quantitative analysis of grasping (pressure and acceleration applied to toys while playing). Each toy was placed on the midline, while the infant was in supine position. Preliminary data show differences in the grasping parameters in relation to infants age and the performed daily training. Ongoing clinical trial will allow a full validation of this new tool for promoting object exploration in preterm infants.
NASA Astrophysics Data System (ADS)
Fornas, D.; Sales, J.; Peñalver, A.; Pérez, J.; Fernández, J. J.; Marín, R.; Sanz, P. J.
2016-03-01
This article presents research on the subject of autonomous underwater robot manipulation. Ongoing research in underwater robotics intends to increase the autonomy of intervention operations that require physical interaction in order to achieve social benefits in fields such as archaeology or biology that cannot afford the expenses of costly underwater operations using remote operated vehicles. Autonomous grasping is still a very challenging skill, especially in underwater environments, with highly unstructured scenarios, limited availability of sensors and adverse conditions that affect the robot perception and control systems. To tackle these issues, we propose the use of vision and segmentation techniques that aim to improve the specification of grasping operations on underwater primitive shaped objects. Several sources of stereo information are used to gather 3D information in order to obtain a model of the object. Using a RANSAC segmentation algorithm, the model parameters are estimated and a set of feasible grasps are computed. This approach is validated in both simulated and real underwater scenarios.
Chen, Juan; Sperandio, Irene; Goodale, Melvyn Alan
2015-01-01
Objects rarely appear in isolation in natural scenes. Although many studies have investigated how nearby objects influence perception in cluttered scenes (i.e., crowding), none has studied how nearby objects influence visually guided action. In Experiment 1, we found that participants could scale their grasp to the size of a crowded target even when they could not perceive its size, demonstrating for the first time that neurologically intact participants can use visual information that is not available to conscious report to scale their grasp to real objects in real scenes. In Experiments 2 and 3, we found that changing the eccentricity of the display and the orientation of the flankers had no effect on grasping but strongly affected perception. The differential effects of eccentricity and flanker orientation on perception and grasping show that the known differences in retinotopy between the ventral and dorsal streams are reflected in the way in which people deal with targets in cluttered scenes. © The Author(s) 2014.
Slip speed feedback for grip force control.
Damian, D D; Arita, A H; Martinez, H; Pfeifer, R
2012-08-01
Grasp stability in the human hand has been resolved by means of an intricate network of mechanoreceptors integrating numerous cues about mechanical events, through an ontogenetic grasp practice. An engineered prosthetic interface introduces considerable perturbation risks in grasping, calling for feedback modalities that address the underlying slip phenomenon. In this study, we propose an enhanced slip feedback modality, with potential for myoelectric-based prosthetic applications, that relays information regarding slip events, particularly slip occurrence and slip speed. The proposed feedback modality, implemented using electrotactile stimulation, was evaluated in psychophysical studies of slip control in a simplified setup. The obtained results were compared with vision and a binary slip feedback that transmits on-off information about slip detection. The slip control efficiency of the slip speed display is comparable to that obtained with vision feedback, and it clearly outperforms the efficiency of the on-off slip modality in such tasks. These results suggest that the proposed tactile feedback is a promising sensory method for the restoration of stable grasp in prosthetic applications.
Neurons in Primary Motor Cortex Encode Hand Orientation in a Reach-to-Grasp Task.
Ma, Chaolin; Ma, Xuan; Fan, Jing; He, Jiping
2017-08-01
It is disputed whether those neurons in the primary motor cortex (M1) that encode hand orientation constitute an independent channel for orientation control in reach-to-grasp behaviors. Here, we trained two monkeys to reach forward and grasp objects positioned in the frontal plane at different orientation angles, and simultaneously recorded the activity of M1 neurons. Among the 2235 neurons recorded in M1, we found that 18.7% had a high correlation exclusively with hand orientation, 15.9% with movement direction, and 29.5% with both movement direction and hand orientation. The distributions of neurons encoding hand orientation and those encoding movement direction were not uniform but coexisted in the same region. The trajectory of hand rotation was reproduced by the firing patterns of the orientation-related neurons independent of the hand reaching direction. These results suggest that hand orientation is an independent component for the control of reaching and grasping activity.
Lee, Sang-Yeol; Park, Yi-Jeong; Park, Hye-Min; Bae, Hae-Jin; Yu, Min-Ji; Choi, Hee-Won; Hwang, Na-Young
2014-02-01
[Purpose] This study verified the changes in muscle activities and grasping power during maximal isometric exercise of the forearm and masseter muscle with and without a mandibular orthopedic repositioning appliance (MORA). It also offers basic data for defining the correlation of function of hand with mouth. [Methods] EMG was used to measure masticatory muscle, flexor bundle and extensor bundle activities with or without MORA while subjects performed the hook grip and pinch grip. The measuring tool used for measuring grip strength was the same as that used for measuring pinch and hook strength. The subjects were 28 healthy young adults. [Result] Muscle activity and grasping power significantly increased when wearing the MORA. [Conclusion] The result indicates that wearing MORA can increase muscle activity and grasping power of forearm and masseter muscle. We think wearing MORA might help improve the function of the forearm because it activates the function of the masseter.
The Extrastriate Body Area Computes Desired Goal States during Action Planning123
2016-01-01
Abstract How do object perception and action interact at a neural level? Here we test the hypothesis that perceptual features, processed by the ventral visuoperceptual stream, are used as priors by the dorsal visuomotor stream to specify goal-directed grasping actions. We present three main findings, which were obtained by combining time-resolved transcranial magnetic stimulation and kinematic tracking of grasp-and-rotate object manipulations, in a group of healthy human participants (N = 22). First, the extrastriate body area (EBA), in the ventral stream, provides an initial structure to motor plans, based on current and desired states of a grasped object and of the grasping hand. Second, the contributions of EBA are earlier in time than those of a caudal intraparietal region known to specify the action plan. Third, the contributions of EBA are particularly important when desired and current object configurations differ, and multiple courses of actions are possible. These findings specify the temporal and functional characteristics for a mechanism that integrates perceptual processing with motor planning. PMID:27066535
Squillace, Mary; Ray, Sharon; Milazzo, Maria
2015-01-01
This study examined the gross grasp strength and fine motor dexterity of adolescents, who are diagnosed with multiple sclerosis (MS). A total sample size of 72 participants between the ages of 13 to 17 was studied. Thirty six with a diagnosis of pediatric relapse remitting MS and 36 matched control participants were selected from various local youth groups. Data on hand strength and dexterity was collected using a dynamometer, nine hole peg board and Purdue pegboard on both groups. Utilizing ANCOVA to describe the differences across the two groups by diagnosis, controlling for age and gender, it was found that the MS group demonstrated significantly decreased dexterity when compared to age and gender matched controls. There was no significant difference in gross grasp strength by diagnostic group. This preliminary study showed that children with a diagnosis of pediatric MS may have differences in fine motor dexterity, but not gross grasp strength from their peers who do not have the diagnosis. Further study is indicated to examine this phenomenon.
NASA Technical Reports Server (NTRS)
Platt, Robert (Inventor); Wampler, II, Charles W. (Inventor); Abdallah, Muhammad E. (Inventor)
2013-01-01
A robotic system includes a robot having manipulators for grasping an object using one of a plurality of grasp types during a primary task, and a controller. The controller controls the manipulators during the primary task using a multiple-task control hierarchy, and automatically parameterizes the internal forces of the system for each grasp type in response to an input signal. The primary task is defined at an object-level of control, e.g., using a closed-chain transformation, such that only select degrees of freedom are commanded for the object. A control system for the robotic system has a host machine and algorithm for controlling the manipulators using the above hierarchy. A method for controlling the system includes receiving and processing the input signal using the host machine, including defining the primary task at the object-level of control, e.g., using a closed-chain definition, and parameterizing the internal forces for each of grasp type.
Sweetwater, Texas Large N Experiment
NASA Astrophysics Data System (ADS)
Sumy, D. F.; Woodward, R.; Barklage, M.; Hollis, D.; Spriggs, N.; Gridley, J. M.; Parker, T.
2015-12-01
From 7 March to 30 April 2014, NodalSeismic, Nanometrics, and IRIS PASSCAL conducted a collaborative, spatially-dense seismic survey with several thousand nodal short-period geophones complemented by a backbone array of broadband sensors near Sweetwater, Texas. This pilot project demonstrates the efficacy of industry and academic partnerships, and leveraged a larger, commercial 3D survey to collect passive source seismic recordings to image the subsurface. This innovative deployment of a large-N mixed-mode array allows industry to explore array geometries and investigate the value of broadband recordings, while affording academics a dense wavefield imaging capability and an operational model for high volume instrument deployment. The broadband array consists of 25 continuously-recording stations from IRIS PASSCAL and Nanometrics, with an array design that maximized recording of horizontal-traveling seismic energy for surface wave analysis over the primary target area with sufficient offset for imaging objectives at depth. In addition, 2639 FairfieldNodal Zland nodes from NodalSeismic were deployed in three sub-arrays: the outlier, backbone, and active source arrays. The backbone array consisted of 292 nodes that covered the entire survey area, while the outlier array consisted of 25 continuously-recording nodes distributed at a ~3 km distance away from the survey perimeter. Both the backbone and outlier array provide valuable constraints for the passive source portion of the analysis. This project serves as a learning platform to develop best practices in the support of large-N arrays with joint industry and academic expertise. Here we investigate lessons learned from a facility perspective, and present examples of data from the various sensors and array geometries. We will explore first-order results from local and teleseismic earthquakes, and show visualizations of the data across the array. Data are archived at the IRIS DMC under stations codes XB and 1B.
Online kinematic regulation by visual feedback for grasp versus transport during reach-to-pinch
Nataraj, Raviraj; Pasluosta, Cristian; Li, Zong-Ming
2014-01-01
Purpose This study investigated novel kinematic performance parameters to understand regulation by visual feedback (VF) of the reaching hand on the grasp and transport components during the reach-to-pinch maneuver. Conventional metrics often signify discrete movement features to postulate sensory-based control effects (e.g., time for maximum velocity to signify feedback delay). The presented metrics of this study were devised to characterize relative vision-based control of the sub-movements across the entire maneuver. Methods Movement performance was assessed according to reduced variability and increased efficiency of kinematic trajectories. Variability was calculated as the standard deviation about the observed mean trajectory for a given subject and VF condition across kinematic derivatives for sub-movements of inter-pad grasp (distance between thumb and index finger-pads; relative orientation of finger-pads) and transport (distance traversed by wrist). A Markov analysis then examined the probabilistic effect of VF on which movement component exhibited higher variability over phases of the complete maneuver. Jerk-based metrics of smoothness (minimal jerk) and energy (integrated jerk-squared) were applied to indicate total movement efficiency with VF. Results/Discussion The reductions in grasp variability metrics with VF were significantly greater (p<0.05) compared to transport for velocity, acceleration, and jerk, suggesting separate control pathways for each component. The Markov analysis indicated that VF preferentially regulates grasp over transport when continuous control is modeled probabilistically during the movement. Efficiency measures demonstrated VF to be more integral for early motor planning of grasp than transport in producing greater increases in smoothness and trajectory adjustments (i.e., jerk-energy) early compared to late in the movement cycle. Conclusions These findings demonstrate the greater regulation by VF on kinematic performance of grasp compared to transport and how particular features of this relativistic control occur continually over the maneuver. Utilizing the advanced performance metrics presented in this study facilitated characterization of VF effects continuously across the entire movement in corroborating the notion of separate control pathways for each component. PMID:24968371
Decoding Information for Grasping from the Macaque Dorsomedial Visual Stream.
Filippini, Matteo; Breveglieri, Rossella; Akhras, M Ali; Bosco, Annalisa; Chinellato, Eris; Fattori, Patrizia
2017-04-19
Neurodecoders have been developed by researchers mostly to control neuroprosthetic devices, but also to shed new light on neural functions. In this study, we show that signals representing grip configurations can be reliably decoded from neural data acquired from area V6A of the monkey medial posterior parietal cortex. Two Macaca fascicularis monkeys were trained to perform an instructed-delay reach-to-grasp task in the dark and in the light toward objects of different shapes. Population neural activity was extracted at various time intervals on vision of the objects, the delay before movement, and grasp execution. This activity was used to train and validate a Bayes classifier used for decoding objects and grip types. Recognition rates were well over chance level for all the epochs analyzed in this study. Furthermore, we detected slightly different decoding accuracies, depending on the task's visual condition. Generalization analysis was performed by training and testing the system during different time intervals. This analysis demonstrated that a change of code occurred during the course of the task. Our classifier was able to discriminate grasp types fairly well in advance with respect to grasping onset. This feature might be important when the timing is critical to send signals to external devices before the movement start. Our results suggest that the neural signals from the dorsomedial visual pathway can be a good substrate to feed neural prostheses for prehensile actions. SIGNIFICANCE STATEMENT Recordings of neural activity from nonhuman primate frontal and parietal cortex have led to the development of methods of decoding movement information to restore coordinated arm actions in paralyzed human beings. Our results show that the signals measured from the monkey medial posterior parietal cortex are valid for correctly decoding information relevant for grasping. Together with previous studies on decoding reach trajectories from the medial posterior parietal cortex, this highlights the medial parietal cortex as a target site for transforming neural activity into control signals to command prostheses to allow human patients to dexterously perform grasping actions. Copyright © 2017 the authors 0270-6474/17/374311-12$15.00/0.
Reaching and Grasping in Autism Spectrum Disorder: A Review of Recent Literature
Sacrey, Lori-Ann R.; Germani, Tamara; Bryson, Susan E.; Zwaigenbaum, Lonnie
2013-01-01
Impairments in motor functioning, which, until recently, have rarely been a primary focus in autism spectrum disorder (ASD) research, may play a key role in the early expression of biological vulnerability and be associated with key social-communication deficits. This review summarizes current knowledge of motor behavior in ASD, focusing specifically on reaching and grasping. Convergent data across the lifespan indicate that impairments to reaching and grasping emerge early in life, affect the planning and execution of motor programs, and may be impacted by additional impairments to sensory control of motor behavior. The relationship between motor impairments and diagnostic outcomes will be discussed. PMID:24478753
Ground Robotic Hand Applications for the Space Program study (GRASP)
NASA Astrophysics Data System (ADS)
Grissom, William A.; Rafla, Nader I.
1992-04-01
This document reports on a NASA-STDP effort to address research interests of the NASA Kennedy Space Center (KSC) through a study entitled, Ground Robotic-Hand Applications for the Space Program (GRASP). The primary objective of the GRASP study was to identify beneficial applications of specialized end-effectors and robotic hand devices for automating any ground operations which are performed at the Kennedy Space Center. Thus, operations for expendable vehicles, the Space Shuttle and its components, and all payloads were included in the study. Typical benefits of automating operations, or augmenting human operators performing physical tasks, include: reduced costs; enhanced safety and reliability; and reduced processing turnaround time.
Ground Robotic Hand Applications for the Space Program study (GRASP)
NASA Technical Reports Server (NTRS)
Grissom, William A.; Rafla, Nader I. (Editor)
1992-01-01
This document reports on a NASA-STDP effort to address research interests of the NASA Kennedy Space Center (KSC) through a study entitled, Ground Robotic-Hand Applications for the Space Program (GRASP). The primary objective of the GRASP study was to identify beneficial applications of specialized end-effectors and robotic hand devices for automating any ground operations which are performed at the Kennedy Space Center. Thus, operations for expendable vehicles, the Space Shuttle and its components, and all payloads were included in the study. Typical benefits of automating operations, or augmenting human operators performing physical tasks, include: reduced costs; enhanced safety and reliability; and reduced processing turnaround time.
Investigation of a playa lake bed using geophysical electrical methods
NASA Astrophysics Data System (ADS)
Herrmenn, M.; Gurrola, H.; William, R.; Montalvo, R.; Horton, S.; Homberg, J.; Allen, T.; Bribiesca, E.; Lindsey, C.; Anderson, H.; Seshadri, S.; Manns, S.; Hassan, A.; Loren, C.
2005-12-01
The 2005 undergraduate applied geophysical class of Texas Tech University conducted a geophysical survey of a playa lake approximately 10 miles northwest of Lubbock Texas. The playa lake is primarily used as grazing land for two llamas and a hand full of sheep, and has been recently used as a dump for broken down sheds and barrels. Our goal was to model the subsurface of the transition from the playa to plains geology and investigate the possible contamination, of the soil and the data, by the metal dumped at the surface. We conducted our survey with and EM31 and homemade D.C. resistivity and SP equipment that allowed students to grasp the theories more clearly. SP readings were collected using clay pots constructed from terracotta pots and copper tubing purchased at the local hardware store and voltage measurements collected with handle held multi-meters. D.C. resistivity data were collected in a dipole-dipole array using 20 nine volt batteries connected in series with a large enough variable resistor and amp meter to regulate steady current flow. A multi meter was used to collect voltage readings. Wenner array data were collected using a home-made multi-filament cable connected switch box to allow a central user to regulate current and take voltage reading. A map of conductivity produced from a 10 m of EM31 reading show that conductivity anomalies mirror topography. The SP profiles show high values in the playa lake that drop off as we move from the clay rich lake bed to normal grassland. Analysis of both the Dipole-Dipole and Wenner array data support a model with 3 flat layers increasing in resistivity with depth. It appears that these remain flat passing beneath the playa and the playa is eroded into these layers.
Community College Faculty Development Program and Student Achievement
ERIC Educational Resources Information Center
Perez, Aaron M.; McShannon, Judy; Hynes, Pat
2012-01-01
Community college administrators look for strategies to help students. GRASP (Gaining Retention and Achievement for Students Program) is a semester-long faculty development program that coaches community college instructors about simple, effective teaching strategies that promote student academic achievement. GRASP is founded on the belief that…
Functional Electrical Therapy Systems: Neuroprostheses for Life-Like Reach and Grasp
2001-10-25
communication channel by means of an infrared link. Keywords – Neuroprosthesis, therapy, reaching, grasping I. INTRODUCTION Functional electrical...present technology and the next generation. Proc 2nd Int Symp IFESS, Burnaby, pp 139-140, 1997. [7] Ocadiz G, Mayagoitia RE. Programmable eight channel
Flat-plate solar array project. Volume 5: Process development
NASA Technical Reports Server (NTRS)
Gallagher, B.; Alexander, P.; Burger, D.
1986-01-01
The goal of the Process Development Area, as part of the Flat-Plate Solar Array (FSA) Project, was to develop and demonstrate solar cell fabrication and module assembly process technologies required to meet the cost, lifetime, production capacity, and performance goals of the FSA Project. R&D efforts expended by Government, Industry, and Universities in developing processes capable of meeting the projects goals during volume production conditions are summarized. The cost goals allocated for processing were demonstrated by small volume quantities that were extrapolated by cost analysis to large volume production. To provide proper focus and coverage of the process development effort, four separate technology sections are discussed: surface preparation, junction formation, metallization, and module assembly.
Phased Array Mirror Extendible Large Aperture (PAMELA) Optics Adjustment
NASA Technical Reports Server (NTRS)
1995-01-01
Scientists at Marshall's Adaptive Optics Lab demonstrate the Wave Front Sensor alignment using the Phased Array Mirror Extendible Large Aperture (PAMELA) optics adjustment. The primary objective of the PAMELA project is to develop methods for aligning and controlling adaptive optics segmented mirror systems. These systems can be used to acquire or project light energy. The Next Generation Space Telescope is an example of an energy acquisition system that will employ segmented mirrors. Light projection systems can also be used for power beaming and orbital debris removal. All segmented optical systems must be adjusted to provide maximum performance. PAMELA is an on going project that NASA is utilizing to investigate various methods for maximizing system performance.
The environment of the wind-wind collision region of η Carinae
NASA Astrophysics Data System (ADS)
Panagiotou, C.; Walter, R.
2018-02-01
Context. η Carinae is a colliding wind binary hosting two of the most massive stars and featuring the strongest wind collision mechanical luminosity. The wind collision region of this system is detected in X-rays and γ-rays and offers a unique laboratory for the study of particle acceleration and wind magneto-hydrodynamics. Aim. Our main goal is to use X-ray observations of η Carinae around periastron to constrain the wind collision zone geometry and understand the reasons for its variability. Methods: We analysed 10 Nuclear Spectroscopic Telescope Array (NuSTAR) observations, which were obtained around the 2014 periastron. The NuSTAR array monitored the source from 3 to 30 keV, which allowed us to grasp the continuum and absorption parameters with very good accuracy. We were able to identify several physical components and probe their variability. Results: The X-ray flux varied in a similar way as observed during previous periastrons and largely as expected if generated in the wind collision region. The flux detected within 10 days of periastron is lower than expected, suggesting a partial disruption of the central region of the wind collision zone. The Fe Kα line is likely broadened by the electrons heated along the complex shock fronts. The variability of its equivalent width indicates that the fluorescence region has a complex geometry and that the source obscuration varies quickly with the line of sight.
The research on multi-projection correction based on color coding grid array
NASA Astrophysics Data System (ADS)
Yang, Fan; Han, Cheng; Bai, Baoxing; Zhang, Chao; Zhao, Yunxiu
2017-10-01
There are many disadvantages such as lower timeliness, greater manual intervention in multi-channel projection system, in order to solve the above problems, this paper proposes a multi-projector correction technology based on color coding grid array. Firstly, a color structured light stripe is generated by using the De Bruijn sequences, then meshing the feature information of the color structured light stripe image. We put the meshing colored grid intersection as the center of the circle, and build a white solid circle as the feature sample set of projected images. It makes the constructed feature sample set not only has the perceptual localization, but also has good noise immunity. Secondly, we establish the subpixel geometric mapping relationship between the projection screen and the individual projectors by using the structure of light encoding and decoding based on the color array, and the geometrical mapping relation is used to solve the homography matrix of each projector. Lastly the brightness inconsistency of the multi-channel projection overlap area is seriously interfered, it leads to the corrected image doesn't fit well with the observer's visual needs, and we obtain the projection display image of visual consistency by using the luminance fusion correction algorithm. The experimental results show that this method not only effectively solved the problem of distortion of multi-projection screen and the issue of luminance interference in overlapping region, but also improved the calibration efficient of multi-channel projective system and reduced the maintenance cost of intelligent multi-projection system.
Control of a Robotic Hand Using a Tongue Control System-A Prosthesis Application.
Johansen, Daniel; Cipriani, Christian; Popovic, Dejan B; Struijk, Lotte N S A
2016-07-01
The aim of this study was to investigate the feasibility of using an inductive tongue control system (ITCS) for controlling robotic/prosthetic hands and arms. This study presents a novel dual modal control scheme for multigrasp robotic hands combining standard electromyogram (EMG) with the ITCS. The performance of the ITCS control scheme was evaluated in a comparative study. Ten healthy subjects used both the ITCS control scheme and a conventional EMG control scheme to complete grasping exercises with the IH1 Azzurra robotic hand implementing five grasps. Time to activate a desired function or grasp was used as the performance metric. Statistically significant differences were found when comparing the performance of the two control schemes. On average, the ITCS control scheme was 1.15 s faster than the EMG control scheme, corresponding to a 35.4% reduction in the activation time. The largest difference was for grasp 5 with a mean AT reduction of 45.3% (2.38 s). The findings indicate that using the ITCS control scheme could allow for faster activation of specific grasps or functions compared with a conventional EMG control scheme. For transhumeral and especially bilateral amputees, the ITCS control scheme could have a significant impact on the prosthesis control. In addition, the ITCS would provide bilateral amputees with the additional advantage of environmental and computer control for which the ITCS was originally developed.
Müller-Lyer figures influence the online reorganization of visually guided grasping movements.
Heath, Matthew; Rival, Christina; Neely, Kristina; Krigolson, Olav
2006-03-01
In advance of grasping a visual object embedded within fins-in and fins-out Müller-Lyer (ML) configurations, participants formulated a premovement grip aperture (GA) based on the size of a neutral preview object. Preview objects were smaller, veridical, or larger than the size of the to-be-grasped target object. As a result, premovement GA associated with the small and large preview objects required significant online reorganization to appropriately grasp the target object. We reasoned that such a manipulation would provide an opportunity to examine the extent to which the visuomotor system engages egocentric and/or allocentric visual cues for the online, feedback-based control of action. It was found that the online reorganization of GA was reliably influenced by the ML figures (i.e., from 20 to 80% of movement time), regardless of the size of the preview object, albeit the small and large preview objects elicited more robust illusory effects than the veridical preview object. These results counter the view that online grasping control is mediated by absolute visual information computed with respect to the observer (e.g., Glover in Behav Brain Sci 27:3-78, 2004; Milner and Goodale in The visual brain in action 1995). Instead, the impact of the ML figures suggests a level of interaction between egocentric and allocentric visual cues in online action control.
Takemura, Naohiro; Fukui, Takao; Inui, Toshio
2015-01-01
In human reach-to-grasp movement, visual occlusion of a target object leads to a larger peak grip aperture compared to conditions where online vision is available. However, no previous computational and neural network models for reach-to-grasp movement explain the mechanism of this effect. We simulated the effect of online vision on the reach-to-grasp movement by proposing a computational control model based on the hypothesis that the grip aperture is controlled to compensate for both motor variability and sensory uncertainty. In this model, the aperture is formed to achieve a target aperture size that is sufficiently large to accommodate the actual target; it also includes a margin to ensure proper grasping despite sensory and motor variability. To this end, the model considers: (i) the variability of the grip aperture, which is predicted by the Kalman filter, and (ii) the uncertainty of the object size, which is affected by visual noise. Using this model, we simulated experiments in which the effect of the duration of visual occlusion was investigated. The simulation replicated the experimental result wherein the peak grip aperture increased when the target object was occluded, especially in the early phase of the movement. Both predicted motor variability and sensory uncertainty play important roles in the online visuomotor process responsible for grip aperture control. PMID:26696874
Feng, Li; Axel, Leon; Chandarana, Hersh; Block, Kai Tobias; Sodickson, Daniel K; Otazo, Ricardo
2016-02-01
To develop a novel framework for free-breathing MRI called XD-GRASP, which sorts dynamic data into extra motion-state dimensions using the self-navigation properties of radial imaging and reconstructs the multidimensional dataset using compressed sensing. Radial k-space data are continuously acquired using the golden-angle sampling scheme and sorted into multiple motion-states based on respiratory and/or cardiac motion signals derived directly from the data. The resulting undersampled multidimensional dataset is reconstructed using a compressed sensing approach that exploits sparsity along the new dynamic dimensions. The performance of XD-GRASP is demonstrated for free-breathing three-dimensional (3D) abdominal imaging, two-dimensional (2D) cardiac cine imaging and 3D dynamic contrast-enhanced (DCE) MRI of the liver, comparing against reconstructions without motion sorting in both healthy volunteers and patients. XD-GRASP separates respiratory motion from cardiac motion in cardiac imaging, and respiratory motion from contrast enhancement in liver DCE-MRI, which improves image quality and reduces motion-blurring artifacts. XD-GRASP represents a new use of sparsity for motion compensation and a novel way to handle motions in the context of a continuous acquisition paradigm. Instead of removing or correcting motion, extra motion-state dimensions are reconstructed, which improves image quality and also offers new physiological information of potential clinical value. © 2015 Wiley Periodicals, Inc.
Feng, Li; Axel, Leon; Chandarana, Hersh; Block, Kai Tobias; Sodickson, Daniel K.; Otazo, Ricardo
2015-01-01
Purpose To develop a novel framework for free-breathing MRI called XD-GRASP, which sorts dynamic data into extra motion-state dimensions using the self-navigation properties of radial imaging and reconstructs the multidimensional dataset using compressed sensing. Methods Radial k-space data are continuously acquired using the golden-angle sampling scheme and sorted into multiple motion-states based on respiratory and/or cardiac motion signals derived directly from the data. The resulting under-sampled multidimensional dataset is reconstructed using a compressed sensing approach that exploits sparsity along the new dynamic dimensions. The performance of XD-GRASP is demonstrated for free-breathing three-dimensional (3D) abdominal imaging, two-dimensional (2D) cardiac cine imaging and 3D dynamic contrast-enhanced (DCE) MRI of the liver, comparing against reconstructions without motion sorting in both healthy volunteers and patients. Results XD-GRASP separates respiratory motion from cardiac motion in cardiac imaging, and respiratory motion from contrast enhancement in liver DCE-MRI, which improves image quality and reduces motion-blurring artifacts. Conclusion XD-GRASP represents a new use of sparsity for motion compensation and a novel way to handle motions in the context of a continuous acquisition paradigm. Instead of removing or correcting motion, extra motion-state dimensions are reconstructed, which improves image quality and also offers new physiological information of potential clinical value. PMID:25809847
Effects of material properties and object orientation on precision grip kinematics.
Paulun, Vivian C; Gegenfurtner, Karl R; Goodale, Melvyn A; Fleming, Roland W
2016-08-01
Successfully picking up and handling objects requires taking into account their physical properties (e.g., material) and position relative to the body. Such features are often inferred by sight, but it remains unclear to what extent observers vary their actions depending on the perceived properties. To investigate this, we asked participants to grasp, lift and carry cylinders to a goal location with a precision grip. The cylinders were made of four different materials (Styrofoam, wood, brass and an additional brass cylinder covered with Vaseline) and were presented at six different orientations with respect to the participant (0°, 30°, 60°, 90°, 120°, 150°). Analysis of their grasping kinematics revealed differences in timing and spatial modulation at all stages of the movement that depended on both material and orientation. Object orientation affected the spatial configuration of index finger and thumb during the grasp, but also the timing of handling and transport duration. Material affected the choice of local grasp points and the duration of the movement from the first visual input until release of the object. We find that conditions that make grasping more difficult (orientation with the base pointing toward the participant, high weight and low surface friction) lead to longer durations of individual movement segments and a more careful placement of the fingers on the object.
Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes
Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas
2014-01-01
Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326
Optimizing pattern recognition-based control for partial-hand prosthesis application.
Earley, Eric J; Adewuyi, Adenike A; Hargrove, Levi J
2014-01-01
Partial-hand amputees often retain good residual wrist motion, which is essential for functional activities involving use of the hand. Thus, a crucial design criterion for a myoelectric, partial-hand prosthesis control scheme is that it allows the user to retain residual wrist motion. Pattern recognition (PR) of electromyographic (EMG) signals is a well-studied method of controlling myoelectric prostheses. However, wrist motion degrades a PR system's ability to correctly predict hand-grasp patterns. We studied the effects of (1) window length and number of hand-grasps, (2) static and dynamic wrist motion, and (3) EMG muscle source on the ability of a PR-based control scheme to classify functional hand-grasp patterns. Our results show that training PR classifiers with both extrinsic and intrinsic muscle EMG yields a lower error rate than training with either group by itself (p<0.001); and that training in only variable wrist positions, with only dynamic wrist movements, or with both variable wrist positions and movements results in lower error rates than training in only the neutral wrist position (p<0.001). Finally, our results show that both an increase in window length and a decrease in the number of grasps available to the classifier significantly decrease classification error (p<0.001). These results remained consistent whether the classifier selected or maintained a hand-grasp.
Action Priority: Early Neurophysiological Interaction of Conceptual and Motor Representations
Koester, Dirk; Schack, Thomas
2016-01-01
Handling our everyday life, we often react manually to verbal requests or instruction, but the functional interrelations of motor control and language are not fully understood yet, especially their neurophysiological basis. Here, we investigated whether specific motor representations for grip types interact neurophysiologically with conceptual information, that is, when reading nouns. Participants performed lexical decisions and, for words, executed a grasp-and-lift task on objects of different sizes involving precision or power grips while the electroencephalogram was recorded. Nouns could denote objects that require either a precision or a power grip and could, thus, be (in)congruent with the performed grasp. In a control block, participants pointed at the objects instead of grasping them. The main result revealed an event-related potential (ERP) interaction of grip type and conceptual information which was not present for pointing. Incongruent compared to congruent conditions elicited an increased positivity (100–200 ms after noun onset). Grip type effects were obtained in response-locked analyses of the grasping ERPs (100–300 ms at left anterior electrodes). These findings attest that grip type and conceptual information are functionally related when planning a grasping action but such an interaction could not be detected for pointing. Generally, the results suggest that control of behaviour can be modulated by task demands; conceptual noun information (i.e., associated action knowledge) may gain processing priority if the task requires a complex motor response. PMID:27973539
Dewar, Michaela T; Carey, David P
2006-01-01
Recent findings of visuomotor immunity to perceptual illusions have been attributed to a perception-action division of labour within two anatomically segregated streams in the visual cortex. However, critics argue that such experimental findings are not valid and have suggested that the perception-action dissociations can be explained away by differential attentional/processing demands, rather than a functional dissociation in the neurologically intact brain: perceptual tasks require processing of the entire illusion display while visuomotor tasks only require processing the target that is acted upon. The present study examined whether grasping of the Müller-Lyer display would remain immune to the illusion when the task required the direction of attention or a related resource towards both Müller-Lyer shafts. Twelve participants were required to match and grasp two Müller-Lyer shafts bimanually (i.e. one with each hand). It was found that bimanual grasping was not significantly affected by the illusion, while there was a highly significant illusion effect on perceptual estimation by matching. Furthermore, it was established that this dissociation did not result from a differing baseline rate of change in manual estimation and grasping aperture to a change in physical object size. These findings provide further support for the postulated perception-action dissociation and fail to uphold the idea that grasping 'immunity' to the Müller-Lyer illusions merely represents an experimental artefact.
1992-09-12
This STS-48 onboard photo is of the Upper Atmosphere Research Satellite (UARS) in the grasp of the RMS (Remote Manipulator System) during deployment, September 1991. UARS gathers data related to the chemistry, dynamics, and energy of the ozone layer. UARS data is used to study energy input, stratospheric photo chemistry, and upper atmospheric circulation. UARS helps us understand and predict how the nitrogen and chlorine cycles, and the nitrous oxides and halo carbons which maintain them, relate to the ozone balance. It also observes diurnal variations in short-lived stratospheric chemical species important to ozone destruction. Data from UARS enables scientists to study ozone depletion in the upper atmosphere.
1991-09-12
This STS-48 onboard photo is of the Upper Atmosphere Research Satellite (UARS) in the grasp of the RMS (Remote Manipulator System) during deployment, September 1991. UARS gathers data related to the chemistry, dynamics, and energy of the ozone layer. UARS data is used to study energy input, stratospheric photo chemistry, and upper atmospheric circulation. UARS helps us understand and predict how the nitrogen and chlorine cycles, and the nitrous oxides and halo carbons which maintain them, relate to the ozone balance. It also observes diurnal variations in short-lived stratospheric chemical species important to ozone destruction. Data from UARS enables scientists to study ozone depletion in the upper atmosphere.
NASA Technical Reports Server (NTRS)
Galeazzi, M.; Prasai, K.; Uprety, Y.; Chiao, M.; Collier, M. R.; Koutroumpa, D.; Porter, F. S.; Snowden, S.; Cravens, T.; Robertson, I.;
2011-01-01
The Diffuse X-rays from the Local galaxy (DXL) mission is an approved sounding rocket project with a first launch scheduled around December 2012. Its goal is to identify and separate the X-ray emission generated by solar wind charge exchange from that of the local hot bubble to improve our understanding of both. With 1,000 square centimeters proportional counters and grasp of about 10 square centimeters sr both in the 1/4 and 3/4 keV bands, DXL will achieve in a 5-minute flight what cannot be achieved by current and future X-ray satellites.
Student designed experiments to learn fluids
NASA Astrophysics Data System (ADS)
Stern, Catalina
2013-11-01
Lasers and high speed cameras are a wonderful tool to visualize the very complex behavior of fluids, and to help students grasp concepts like turbulence, surface tension and vorticity. In this work we present experiments done by physics students in their senior year at the School of Science of the National University of Mexico as a final project in the continuum mechanics course. Every semester, the students make an oral presentation of their work and videos and images are kept in the web page ``Pasión por los Fluidos''. I acknowledge support from the Physics Department of Facultad de Ciencias, Universidad Nacional Autónoma de México.
In this medium close-up view, captured by an Electronic Still Camera (ESC), the Spartan 207
NASA Technical Reports Server (NTRS)
1996-01-01
STS-77 ESC VIEW --- In this medium close-up view, captured by an Electronic Still Camera (ESC), the Spartan 207 free-flyer is held in the grasp of the Space Shuttle Endeavour's Remote Manipulator System (RMS) following its re-capture on May 21, 1996. The six-member crew has spent a portion of the early stages of the mission in various activities involving the Spartan 207 and the related Inflatable Antenna Experiment (IAE). The Spartan project is managed by NASA's Goddard Space Flight Center (GSFC) for NASA's Office of Space Science, Washington, D.C. GMT: 09:38:05.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1983-11-15
A Photovoltaic Metallization Research Forum, under the sponsorship of the Jet Propulsion Laboratory's Flat-Plate Solar Array Project and the US Department of Energy, was held March 16-18, 1983 at Pine Mountain, Georgia. The Forum consisted of five sessions, covering (1) the current status of metallization systems, (2) system design, (3) thick-film metallization, (4) advanced techniques and (5) future metallization challenges. Twenty-three papers were presented.
Operation and performance of the EEE network array for the detection of cosmic rays
NASA Astrophysics Data System (ADS)
Abbrescia, M.; Avanzini, C.; Baldini, L.; Baldini Ferroli, R.; Batignani, G.; Bencivenni, G.; Bossini, E.; Chiavassa, A.; Cicalò, C.; Cifarelli, L.; Coccia, E.; Corvaglia, A.; De Gruttola, D.; De Pasquale, S.; Di Giovanni, A.; D'Incecco, M.; Dreucci, M.; Fabbri, F. L.; Fattibene, E.; Ferraro, A.; Frolov, V.; Galeotti, P.; Garbini, M.; Gemme, G.; Gnesi, I.; Grazzi, S.; Gustavino, C.; Hatzifotiadou, D.; La Rocca, P.; Licciulli, F.; Maggiora, A.; Maragoto Rodriguez, O.; Maron, G.; Martelli, B.; Mazziotta, M. N.; Miozzi, S.; Nania, R.; Noferini, F.; Nozzoli, F.; Panareo, M.; Panetta, M. P.; Paoletti, R.; Park, W.; Perasso, L.; Pilo, F.; Piragino, G.; Riggi, F.; Righini, G. C.; Sartorelli, G.; Scapparone, E.; Schioppa, M.; Scribano, A.; Selvi, M.; Serci, S.; Siddi, E.; Squarcia, S.; Stori, L.; Taiuti, M.; Terreni, G.; Visnyei, O. B.; Vistoli, M. C.; Votano, L.; Williams, M. C. S.; Zani, S.; Zichichi, A.; Zuyeuski, R.
2017-02-01
The EEE (Extreme Energy Events) Project is an experiment for the detection of cosmic ray muons by means of a sparse array of telescopes, each made of three Multigap Resistive Plate Chambers (MRPC), distributed over all the Italian territory and at CERN. The main scientific goals of the Project are the investigation of the properties of the local muon flux, the detection of Extensive Air Showers (EAS) and the search for long-distance correlations between far telescopes. The Project is also characterized by a strong educational and outreach aspect since the telescopes are managed by teams of students and teachers who had previously constructed them at CERN. In this paper an overall description of the experiment is given, including the design, construction and performance of the telescopes. The operation of the whole array, which currently consists of more than 50 telescopes, is also presented by showing the most recent physics results.
Business planning: a template for success.
Dye, Judy
2002-01-01
Because managing a laboratory, or any health-care entity, is as much a business as a service, it is important for you to have a good grasp on how you can take opportunities from idea conception to implementation to assessment/revision. Regardless of the size of your proposed project, you need to consider a number of factors, among them: your history and what opportunities you can seize from your strengths and weaknesses; the overall business climate; anticipated costs; staff involvement; how you will market your project; and what measures to use to determine your success. Above all else, you need to set goals, both ultimate and intermediate, to instill focus, incentive, and a sense of achievement. The next time someone on your staff says, "Why don't we try that?," refer to this Template Topic. It can serve as a tool to help you determine whether you should try "that" and be the compass that helps guide your efforts.
NASA Astrophysics Data System (ADS)
Holm Jacobsen, Bo
2010-05-01
The ambition is to make the citizen (i.e. pupil/student/scholar/voter/journalist/politician) comprehend better and more scientifically all time scales from the lifespan of the universe to the personal life project by a consistent geographical mapping of time at a scale of 1 mm per 100 years. The processes which change earth systems like life, climate, topography and plate tectonics operate at very different timescales. The understanding of these systems is essential not only for students and scholars of earth science but also for pupils, voters and politicians who make decisions of possibly significant consequence to climate and biodiversity not only for our generation but for thousands or even millions of years ahead. With a consistent linear mapping of time to a scale of 1 millimetre per 100 years, historical time (
Use of Grasp Force Focus Positioning to Enhance the Torque Resistance Capability of Robotic Grasps
1990-12-13
8217SEQUENTIAL’, 124 1 FORM=’FORMATTED’) 125 OPEN(18,FILE=’CNTCTS’//RUN//’. DkT ’ ,STATUS=’NEW’, 126 1 ACCESS=’SEqtJENTIAL’, 127 1 FO’FOMTED’) 128 OPEN(19,FILE
Film Perception Under Ordinary Viewing Conditions
ERIC Educational Resources Information Center
Hegarty, Seamus F.
1978-01-01
After viewing a film, a sample of 10 and 11 year old children completed questionnaires which gave information on their grasp of the film's content, on matching variables, and on design factors. In this way it was possible to examine patterns in the grasp of content and relate them to other variables. (Author)
University Students' Grasp of Inflection Points
ERIC Educational Resources Information Center
Tsamir, Pessia; Ovodenko, Regina
2013-01-01
This paper describes university students' grasp of inflection points. The participants were asked what inflection points are, to mark inflection points on graphs, to judge the validity of related statements, and to find inflection points by investigating (1) a function, (2) the derivative, and (3) the graph of the derivative. We found four…
Measuring research progress in photovoltaics
NASA Technical Reports Server (NTRS)
Jackson, B.; Mcguire, P.
1986-01-01
The role and some results of the project analysis and integration function in the Flat-plate Solar Array (FSA) Project are presented. Activities included supporting the decision-making process, preparation of plans for project direction, setting goals for project activities, measuring progress within the project, and the development and maintenance of analytical models.