Karimov, Jamshid H; Sunagawa, Gengo; Such, Kimberly A; Sale, Shiva; Golding, Leonard A R; Moazami, Nader; Fukamachi, Kiyotaka
2015-12-01
The biocompatibility assessment of the Cleveland Clinic continuous-flow total artificial heart is an important part of the device developmental program. Surgical and postoperative management are key factors in achieving optimal outcomes. However, the presence of vascular anatomical abnormalities in experimental animal models is often unpredictable and may worsen the expected outcomes. We report a technical impediment encountered during total artificial heart implantation complicated by unfavorable bovine anatomy of the ascending aorta and brachiocephalic arterial trunk.
Ethical Analysis of Withdrawing Total Artificial Heart Support.
DeMartino, Erin S; Wordingham, Sara E; Stulak, John M; Boilson, Barry A; Fuechtmann, Kayla R; Singh, Nausheen; Sulmasy, Daniel P; Pajaro, Octavio E; Mueller, Paul S
2017-05-01
To describe the characteristics of patients who undergo withdrawal of total artificial heart support and to explore the ethical aspects of withdrawing this life-sustaining treatment. We retrospectively reviewed the medical records of all adult recipients of a total artificial heart at Mayo Clinic from the program's inception in 2007 through June 30, 2015. Management of other life-sustaining therapies, approach to end-of-life decision making, engagement of ethics and palliative care consultation, and causes of death were analyzed. Of 47 total artificial heart recipients, 14 patients or their surrogates (30%) requested withdrawal of total artificial heart support. No request was denied by treatment teams. All 14 patients were supported with at least 1 other life-sustaining therapy. Only 1 patient was able to participate in decision making. It is widely held to be ethically permissible to withdraw a life-sustaining treatment when the treatment no longer meets the patient's health care-related goals (ie, the burdens outweigh the benefits). These data suggest that some patients, surrogates, physicians, and other care providers believe that this principle extends to the withdrawal of total artificial heart support. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Thrombotic Depositions on Right Impeller of Double-Ended Centrifugal Total Artificial Heart In Vivo.
Karimov, Jamshid H; Horvath, David J; Okano, Shinji; Goodin, Mark; Sunagawa, Gengo; Byram, Nicole; Moazami, Nader; Golding, Leonard A R; Fukamachi, Kiyotaka
2017-05-01
The development of total artificial heart devices is a complex undertaking that includes chronic biocompatibility assessment of the device. It is considered particularly important to assess whether device design and features can be compatible long term in a biological environment. As part of the development program for the Cleveland Clinic continuous-flow total artificial heart (CFTAH), we evaluated the device for signs of thrombosis and biological material deposition in four animals that had achieved the intended 14-, 30-, or 90-day durations in each respective experiment. Explanted CFTAHs were analyzed for possible clot buildup at "susceptible" areas inside the pump, particularly the right pump impeller. Depositions of various consistency and shapes were observed. We here report our findings, along with macroscopic and microscopic analysis post explant, and provide computational fluid dynamics data with its potential implications for thrombus formation. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Biomedical engineering support. Final report, June 15, 1971--June 30, 1979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolff, W.J.; Sandquist, G.; Olsen, D.B.
On June 15, 1971 the Institute for Biomedical Engineering at the University of Utah contracted with the USAEC to provide biomedical support for an Artificial Heart Program. The goal of the program was to conceive, design, construct and test a prototype artificial heart system powered by an implantable radioisotope heat source. The system would serve as a total artificial heart for animal experiments and for studies directed at developing a total heart replacement system for humans. The major responsibilities of the Institute during the eight year contract period were to design, construct and test all blood handling components of themore » system and prove in vivo accommodation, performance and adequacy of the system in experimental animals. Upon completion of development of the Implantable Version of the Bench Model Blood Pump, a long series of comprehensive in vitro and in vivo experiments were conducted. In vivo experiments with the system conducted in calves demonstrated the general accommodation, adequate performance and good capacity to sustain the calf as a heart model for up to 36 days. During the more successful in vivo experiments the implanted calves were able to eat, drink, stand, exercise on a treadmill, and exhibited normal blood chemistry and pulmonary function.« less
Artificial heart and assist devices: directions, needs, costs, societal and ethical issues.
Van Citters, R L; Bauer, C B; Christopherson, L K; Eberhart, R C; Eddy, D M; Frye, R L; Jonsen, A R; Keller, K H; Levine, R J; McGoon, D C
1985-11-01
A Working Group appointed by the Director of the National Heart, Lung, and Blood Institute (NHBLI) has reviewed the current status of mechanical circulatory support systems (MCSS), and has examined the potential need for such devices, their cost, and certain societal and ethical issues related to their use. The media have reported the limited clinical investigative use of pneumatically energized total artificial hearts (which actually replace the patient's heart) and left ventricular assist devices (which support or replace the function of the left ventricle by pumping blood from the left heart to the aorta with the patient's heart in place). However, electrically energized systems, which will allow full implantation, permit relatively normal everyday activity, and involve battery exchange or recharge two or three times a day, are currently approaching long-term validation in animals prior to clinical testing. Such long-term left ventricular assist devices have been the primary goal of the NHLBI targeted artificial heart program. Although the ventricular assist device is regarded as an important step in the sequence of MCSS development, the Working Group believes that a fully implantable, long-term, total artificial heart will be a clinical necessity and recommends that the mission of the targeted program include the development of such systems. Past estimates of the potential usage of artificial hearts have been reviewed in the context of advances in medical care and in the prevention of cardiovascular disease. In addition, a retrospective analysis of needs was carried out within a defined population. The resulting projection of 17,000-35,000 cases annually, in patients below age 70, falls within the general range of earlier estimates, but is highly sensitive to many variables. In the absence of an actual base of data and experience with MCSS, projection of costs and prognoses was carried out using explicit sets of assumptions. The total cost of a left ventricular assist device, its implantation and maintenance for a projected average of 4 1/2 years of survival might be approximately $150,000 (in 1983 dollars). The gross annual cost to society could fall in the range of $2.5-$5 billion. Ethical issues associated with use of the artificial heart are not unique. For individual patients these relate primarily to risk-benefit, informed consent, patient selection, and privacy. However, for society as a whole, the larger concern relates to the distribution of national resources.(ABSTRACT TRUNCATED AT 400 WORDS)
Computed Flow Through An Artificial Heart And Valve
NASA Technical Reports Server (NTRS)
Rogers, Stuart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee
1994-01-01
NASA technical memorandum discusses computations of flow of blood through artificial heart and through tilting-disk artificial heart valve. Represents further progress in research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478). One purpose of research to exploit advanced techniques of computational fluid dynamics and capabilities of supercomputers to gain understanding of complicated internal flows of viscous, essentially incompressible fluids like blood. Another to use understanding to design better artificial hearts and valves.
[An artificial heart: bridge to transplantation or permanent?].
de Mol, Bas A J M; Lahpor, Jaap
2013-01-01
An artificial heart is a continuous-flow pump device with a constant output, which usually supports the left ventricle. Over the past five years, survival rates with an artificial heart have increased dramatically, but with an annual mortality of 10% per year compared with 6% for heart transplantation the artificial heart is mainly a 'bridge to transplantation' or an alternative for those patients who are not suitable for heart transplant, 'destination therapy'. It is anticipated that the number and severity of complications will decrease as a result of technological progress. The artificial heart could then become a long-term treatment option providing a good quality of life and thus become equivalent to a heart transplant.
Non-Nutritive Sweeters (Artificial Sweeteners)
... a Healthy Heart Healthy Kids Our Kids Programs Childhood Obesity What is childhood obesity? Overweight in Children BMI in Children Is Childhood Obesity an Issue in Your Home? Addressing your Child's ...
Simulation of Blood flow in Artificial Heart Valve Design through Left heart
NASA Astrophysics Data System (ADS)
Hafizah Mokhtar, N.; Abas, Aizat
2018-05-01
In this work, an artificial heart valve is designed for use in real heart with further consideration on the effect of thrombosis, vorticity, and stress. The design of artificial heart valve model is constructed by Computer-aided design (CAD) modelling and simulated using Computational fluid dynamic (CFD) software. The effect of blood flow pattern, velocity and vorticity of the artificial heart valve design has been analysed in this research work. Based on the results, the artificial heart valve design shows that it has a Doppler velocity index that is less than the allowable standards for the left heart with values of more than 0.30 and less than 2.2. These values are safe to be used as replacement of the human heart valve.
Computed Flow Through An Artificial Heart Valve
NASA Technical Reports Server (NTRS)
Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee
1994-01-01
Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).
Airway Complications of Total Artificial Heart.
Pathak, Vikas; Donovan, Colin; Malhotra, Rajiv
2017-02-01
The total artificial heart is the mechanical device which is used as a bridge to the heart transplant in patients with biventricular failure. Due to the mechanical nature of the device, patients receiving total artificial heart (TAH) require to be on anticoagulation therapy. Hemorrhage and coagulopathy are few of the known complications of TAH.
Kiselev, Iu M; Mordashev, V M; Osipov, A P; Shumakov, V I
1990-01-01
The authors review the thermodynamic bases and physiological limitations of the applicability of thermal engines for driving artificial heart ventricles. Show that the thermodynamic characteristics of Stirling and Brighton cycles do not make it possible to effectively use cycle-based engines in the artificial heart. A steam engine operating in accordance with the Rankine cycle may be regarded as an optimum type engine for that purpose. Demonstrate that according to the rules of physiology, use should be made of a separate driving of artificial heart ventricles by two independently operating steam engines. Provide the characteristics of the Soviet artificial heart "MIKRON" acceptable for implantation into the orthotopic position.
Spiliopoulos, Sotirios; Hergesell, Vera; Wasler, Andrae; Dapunt, Otto
2018-06-14
Due to the declining instances of organ donation, total artificial heart (TAH) therapy is of increasing importance for the management of end-stage biventricular heart failure. We introduce the currently most important established and novel TAH systems (SynCardia, CARMAT, ReinHeart, BiVACOR), report clinical outcomes and discuss technical requirements for the successful implementation of TAH therapy as an alternative to cardiac transplantation.
Heart failure - surgeries and devices
... right ventricular assist devices (RVAD) or a total artificial hearts. They are considered for use if you have ... be on a heart-lung bypass machine. Total artificial hearts are being developed, but are not yet in ...
Numerical Simulation Of Flow Through An Artificial Heart
NASA Technical Reports Server (NTRS)
Rogers, Stuart; Kutler, Paul; Kwak, Dochan; Kiris, Centin
1991-01-01
Research in both artificial hearts and fluid dynamics benefits from computational studies. Algorithm that implements Navier-Stokes equations of flow extended to simulate flow of viscous, incompressible blood through articifial heart. Ability to compute details of such flow important for two reasons: internal flows with moving boundaries of academic interest in their own right, and many of deficiencies of artificial hearts attributable to dynamics of flow.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-11
... heart regarding this restriction. Although Congress did not prohibit LSC from retaining the restriction... distinction to be artificial and not necessary to effectuate Congress' intention. LSC also believes that not...
[Review of wireless energy transmission system for total artificial heart].
Zhang, Chi; Yang, Ming
2009-11-01
This paper sums up the fundamental structure of wireless energy transmission system for total artificial heart, and compares the key parameters and performance of some representative systems. After that, it is discussed that the future development trend of wireless energy transmission system for total artificial heart.
Moderate hypothermia technique for chronic implantation of a total artificial heart in calves.
Karimov, Jamshid H; Grady, Patrick; Sinkewich, Martin; Sunagawa, Gengo; Dessoffy, Raymond; Byram, Nicole; Moazami, Nader; Fukamachi, Kiyotaka
2017-06-01
The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.
Initial in vitro testing of a paediatric continuous-flow total artificial heart.
Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader
2018-06-01
Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.
Design and performance of heart assist or artificial heart control systems
NASA Technical Reports Server (NTRS)
Webb, J. A., Jr.; Gebben, V. D.
1978-01-01
The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.
Hosseinian, Leila; Levin, Matthew A; Fischer, Gregory W; Anyanwu, Anelechi C; Torregrossa, Gianluca; Evans, Adam S
2015-01-01
The Total Artificial Heart (Syncardia, Tucson, AZ) is approved for use as a bridge-to-transplant or destination therapy in patients who have irreversible end-stage biventricular heart failure. We present a unique case, in which the inferior vena cava compression by a total artificial heart was initially masked for days by the concurrent placement of an extracorporeal membrane oxygenation cannula. This is the case of a 33-year-old man admitted to our institution with recurrent episodes of ventricular tachycardia requiring emergent total artificial heart and venovenous extracorporeal membrane oxygenation placement. This interesting scenario highlights the importance for critical care physicians to have an understanding of exact anatomical localization of a total artificial heart, extracorporeal membrane oxygenation, and their potential interactions. In total artificial heart patients with hemodynamic compromise or reduced device filling, consideration should always be given to venous inflow compression, particularly in those with smaller body surface area. Transesophageal echocardiogram is a readily available diagnostic tool that must be considered standard of care, not only in the operating room but also in the ICU, when dealing with this complex subpopulation of cardiac patients.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-26
... itself has had a change of heart regarding this restriction. Although Congress did not prohibit LSC from... performed. LSC continues to find such a distinction to be artificial and not necessary to effectuate...
Antretter, H; Dumfarth, J; Höfer, D
2015-09-01
To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.
Artificial heart for humanoid robot
NASA Astrophysics Data System (ADS)
Potnuru, Akshay; Wu, Lianjun; Tadesse, Yonas
2014-03-01
A soft robotic device inspired by the pumping action of a biological heart is presented in this study. Developing artificial heart to a humanoid robot enables us to make a better biomedical device for ultimate use in humans. As technology continues to become more advanced, the methods in which we implement high performance and biomimetic artificial organs is getting nearer each day. In this paper, we present the design and development of a soft artificial heart that can be used in a humanoid robot and simulate the functions of a human heart using shape memory alloy technology. The robotic heart is designed to pump a blood-like fluid to parts of the robot such as the face to simulate someone blushing or when someone is angry by the use of elastomeric substrates and certain features for the transport of fluids.
Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias
2016-10-21
The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].
Andrade, A; Nicolosi, D; Lucchi, J; Biscegli, J; Arruda, A C; Ohashi, Y; Mueller, J; Tayama, E; Glueck, J; Nosé, Y
1999-09-01
Leading international institutions are designing and developing various types of ventricular assist devices (VAD) and total artificial hearts (TAH). Some of the commercially available pulsatile VADs are not readily implantable into the thoracic cavity of smaller size patients because of size limitation. The majority of the TAH dimensions requires the removal of the patients' native heart. A miniaturized artificial heart, the auxiliary total artificial heart (ATAH), is being developed in these authors' laboratories. This device is an electromechanically driven ATAH using a brushless direct current (DC) motor fixed in a center metallic piece. This pusher plate-type ATAH control is based on Frank-Starling's law. The beating frequency is regulated through the change of the left preload, assisting the native heart in obtaining adequate blood flow. With the miniaturization of this pump, the average sized patient can have the surgical implantation procedure in the right thoracic cavity without removing the native heart. The left and right stroke volumes are 35 and 32 ml, respectively. In vitro tests were conducted, and the performance curves demonstrate that the ATAH produces 5 L/min of cardiac output at 180 bpm (10 mmHg of left inlet mean pressure and 100 mm Hg of left outlet mean pressure). Taking into account that this ATAH is working along with the native heart, this output is more than satisfactory for such a device.
Total Artificial Heart as Rescue Therapy for Primary Graft Failure in an Infant.
Ziegler, Luke A; Sainathan, Sandeep; Morell, Victor O; Sharma, Mahesh S
2018-04-01
An infant unable to be weaned from cardiopulmonary bypass after orthotopic heart transplantation was cannulated for extracorporeal membrane oxygenation. During the next 3 days, allograft failure and intracardiac thrombosis necessitated cardiectomy. To provide acute mechanical circulatory support, artificial atrial chambers were constructed with Gore-Tex conduits and PediMag centrifugal pumps were connected to each by Berlin Heart EXCOR cannulae. The PediMag pumps were subsequently exchanged for 10-mL Berlin Heart EXCOR pumps. After 60 days of support by total artificial heart, the patient was bridged successfully to a second heart transplant. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Total artificial heart implantation in a young Marfan syndrome patient.
Rao, Prashant; Keenan, Jack B; Rajab, Taufiek K; Kim, Samuel; Smith, Richard; Amabile, Orazio; Khalpey, Zain
2018-03-01
Cardiovascular complications represent the leading cause of morbidity and mortality in patients with Marfan syndrome. Here, we describe a unique case where a total artificial heart was implanted in a young Marfan syndrome woman. A 22-year-old postpartum African American female with Marfan syndrome developed multiple severe valve dysfunction and biventricular failure that was refractory to medical management. She previously had a Bentall procedure for Type A aortic dissection and repair of a Type B dissection. We implanted a total artificial heart with a good outcome. Total artificial heart is a durable option for severe biventricular failure and multiple valvular dysfunction as a bridge to transplant in a young patient with Marfan syndrome.
FLUID MECHANICS OF ARTIFICIAL HEART VALVES
Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P
2009-01-01
SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329
Fluid mechanics of artificial heart valves.
Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P
2009-02-01
1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.
Perioperative Care of the Patient With the Total Artificial Heart.
Yaung, Jill; Arabia, Francisco A; Nurok, Michael
2017-05-01
Advanced heart failure continues to be a leading cause of morbidity and mortality despite improvements in pharmacologic therapy. High demand for cardiac transplantation and shortage of donor organs have led to an increase in the utilization of mechanical circulatory support devices. The total artificial heart is an effective biventricular assist device that may be used as a bridge to transplant and that is being studied for destination therapy. This review discusses the history, indications, and perioperative management of the total artificial heart with emphasis on the postoperative concerns.
Tatsumi, Eisuke; Nakatani, Takeshi; Imachi, Kou; Umezu, Mitsuo; Kyo, Shun-Ei; Sase, Kazuhiro; Takatani, Setsuo; Matsuda, Hikaru
2007-01-01
A series of guidelines for development and assessment of next-generation medical devices has been drafted under an interagency collaborative project by the Ministry of Health, Labor and Welfare and the Ministry of Economy, Trade and Industry. The working group for assessment guidelines of next-generation artificial hearts reviewed the trend in the prevalence of heart failure and examined the potential usefulness of such devices in Japan and in other countries as a fundamental part of the process of establishing appropriate guidelines. At present, more than 23 million people suffer from heart failure in developed countries, including Japan. Although Japan currently has the lowest mortality from heart failure among those countries, the number of patients is gradually increasing as our lifestyle becomes more Westernized; the associated medical expenses are rapidly growing. The number of heart transplantations, however, is limited due to the overwhelming shortage of donor hearts, not only in Japan but worldwide. Meanwhile, clinical studies and surveys have revealed that the major causes of death in patients undergoing long-term use of ventricular assist devices (VADs) were infection, thrombosis, and mechanical failure, all of which are typical of VADs. It is therefore of urgent and universal necessity to develop next-generation artificial hearts that have excellent durability to provide at least 2 years of event-free operation with a superior quality of life and that can be used for destination therapy to save patients with irreversible heart failure. It is also very important to ensure that an environment that facilitates the development, testing, and approval evaluation processes of next-generation artificial hearts be established as soon as possible.
... your body: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Recently placed artificial joints Certain types of vascular stents Pain pumps ...
Glyantsev, Sergey P; Tchantchaleishvili, Vakhtang; Bockeria, Leo A
2016-01-01
The world's first implantable total artificial heart was designed by Vladimir Demikhov as a fourth year biology student in Voronezh, Soviet Union, in 1937. As a prototype of his device, Demikhov must have used an apparatus for extracorporeal blood circulation invented by Sergei Bryukhonenko of Moscow. The device was the size of a dog's native heart and consisted of two diaphragm pumps brought into motion by an electric motor. A dog with an implanted device lived for 2.5 hours. In addition to having the prototype, the preconditions for Demikhov's artificial heart creation were his manual dexterity, expertise in animal physiology, and his mechanistic worldview.
Total Artificial Heart Implantation After Undifferentiated High-Grade Sarcoma Excision
Kremer, Jamila; Farag, Mina; Arif, Rawa; Brcic, Andreas; Sabashnikov, Anton; Schmack, Bastian; Popov, Aron-Frederik; Karck, Matthias; Dohmen, Pascal M.; Ruhparwar, Arjang; Weymann, Alexander
2016-01-01
Background Total artificial heart (TAH) implantation in patients with aggressive tumor infiltration of the heart can be challenging. Case Report We report on a patient with a rare primary undifferentiated high-grade spindle cell sarcoma of the mitral valve and in the left atrium, first diagnosed in 2014. The referring center did a first resection in 2014. In the course of 17 months, computer tomography (CT) scan again showed massive invasion of the mitral valve and left atrium. Partial resection and mitral valve replacement was not an option. We did a subtotal heart excision with total artificial heart implantation. In this report we discuss complications, risk factors, and perioperative management of this patient. Conclusions Patients with aggressive tumors of the heart can be considered for TAH implantation. PMID:27803495
Total Artificial Heart Implantation After Undifferentiated High-Grade Sarcoma Excision.
Kremer, Jamila; Farag, Mina; Arif, Rawa; Brcic, Andreas; Sabashnikov, Anton; Schmack, Bastian; Popov, Aron-Frederik; Karck, Matthias; Dohmen, Pascal M; Ruhparwar, Arjang; Weymann, Alexander
2016-11-02
BACKGROUND Total artificial heart (TAH) implantation in patients with aggressive tumor infiltration of the heart can be challenging. CASE REPORT We report on a patient with a rare primary undifferentiated high-grade spindle cell sarcoma of the mitral valve and in the left atrium, first diagnosed in 2014. The referring center did a first resection in 2014. In the course of 17 months, computer tomography (CT) scan again showed massive invasion of the mitral valve and left atrium. Partial resection and mitral valve replacement was not an option. We did a subtotal heart excision with total artificial heart implantation. In this report we discuss complications, risk factors, and perioperative management of this patient. CONCLUSIONS Patients with aggressive tumors of the heart can be considered for TAH implantation.
Cook, Jason A; Shah, Keyur B; Quader, Mohammed A; Cooke, Richard H; Kasirajan, Vigneshwar; Rao, Kris K; Smallfield, Melissa C; Tchoukina, Inna; Tang, Daniel G
2015-12-01
The total artificial heart (TAH) is a form of mechanical circulatory support in which the patient's native ventricles and valves are explanted and replaced by a pneumatically powered artificial heart. Currently, the TAH is approved for use in end-stage biventricular heart failure as a bridge to heart transplantation. However, with an increasing global burden of cardiovascular disease and congestive heart failure, the number of patients with end-stage heart failure awaiting heart transplantation now far exceeds the number of available hearts. As a result, the use of mechanical circulatory support, including the TAH and left ventricular assist device (LVAD), is growing exponentially. The LVAD is already widely used as destination therapy, and destination therapy for the TAH is under investigation. While most patients requiring mechanical circulatory support are effectively treated with LVADs, there is a subset of patients with concurrent right ventricular failure or major structural barriers to LVAD placement in whom TAH may be more appropriate. The history, indications, surgical implantation, post device management, outcomes, complications, and future direction of the TAH are discussed in this review.
Karimov, Jamshid H; Horvath, David; Sunagawa, Gengo; Byram, Nicole; Moazami, Nader; Golding, Leonard A R; Fukamachi, Kiyotaka
2015-12-01
Post-explant evaluation of the continuous-flow total artificial heart in preclinical studies can be extremely challenging because of the device's unique architecture. Determining the exact location of tissue regeneration, neointima formation, and thrombus is particularly important. In this report, we describe our first successful experience with visualizing the Cleveland Clinic continuous-flow total artificial heart using a custom-made high-definition miniature camera.
Heart valve surgery - series (image)
... heart valves are either natural (biologic) or artificial (mechanical). Natural valves are from human donors (cadavers), modified ... artificial valves will require anticoagulation. The advantage of mechanical valves is that they last longer-thus, the ...
... the test, tell your provider if you have: Artificial heart valves Brain aneurysm clips Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not ... artificial joints Vascular stents Worked with sheet metal in ...
Magnetic resonance angiography
... your provider if you have: Brain aneurysm clips Artificial heart valve Heart defibrillator or pacemaker Inner ear (cochlear) implants Insulin or chemotherapy port Intrauterine device (IUD) Kidney ... artificial joints Vascular stent Worked with sheet metal in ...
Successful heart transplant after 1374 days living with a total artificial heart.
Gerosa, Gino; Gallo, Michele; Bottio, Tomaso; Tarzia, Vincenzo
2016-04-01
The CardioWest Total Artificial Heart (CW-TAH) has been approved as a temporary device for bridge to cardiac transplantation and is under investigation for destination therapy by US Food and Drug Administration (FDA). We herein report the longest worldwide survival out of hospital (1374 days) of a patient supported with Cardio West Total Artificial Heart (CW-TAH). This experience is intended as a proof of concept of using CW-TAH as the destination therapy in patients with biventricular failure. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Sleep and wake phase of heart beat dynamics by artificial insymmetrised patterns
NASA Astrophysics Data System (ADS)
Dudkowska, A.; Makowiec, D.
2004-05-01
In order to determine differences between healthy patients and patients with congestive heart failure we apply the artificial insymmetrised pattern (AIP) method. The AIP method by exploring a human eye ability to extract regularities and read symmetries in a dot pattern, serves a tool for qualitative discrimination of heart rate states.
Design of a hydraulic analog of the circulatory system for evaluating artificial hearts.
Donovan, F M
1975-01-01
A major problem in improving artificial heart designs is the absence of methods for accurate in vitro testing of artificial heart systems. A mock circulatory system has been constructed which hydraulically simulates the systemic and pulmonary circulations of the normal human. The device is constructed of 1/2 in. acrylic sheet and has overall dimensions of 24 in. wide, 16 in. tall, and 8 in. deep. The artificial heart to be tested is attached to the front of the device, and pumps fluid from the systemic venous chamber into the pulmonary arterial chamber and from the pulmonary venous chamber into the systemic arterial chamber. Each of the four chambers is hermetically sealed. The compliance of each chamber is determined by the volume of air trapped above the fluid in that chamber. The pulmonary and systemic resistances are set automatically by bellows-operated valves to simulate the barroreceptor response in the systemic arteries and the passive pulmonary resistance response in the pulmonary arteries. Cardiac output is measured by a turbine flowmeter in the systemic circulation. Results using the Kwan-Gett artificial heart show a good comparison between the mock circulatory system response and the calf response.
Wrobeln, Anna; Schlüter, Klaus D; Linders, Jürgen; Zähres, Manfred; Mayer, Christian; Kirsch, Michael; Ferenz, Katja B
2017-06-01
The aim of this study was to prove whether albumin-derived perfluorocarbon-based nanoparticles (capsules) can operate as a novel artificial oxygen carrier in a rat Langendorff-heart perfusion model. Hearts perfused with capsules showed increased left ventricular pressure and rate pressure product compared to hearts perfused with pure Krebs-Henseleit (KH)-buffer. The capsules prevented the myocardium from functional fail when in their absence a noxious ischemia was observed. Capsules did not change rheological properties of KH-buffer and could repeatedly reload with oxygen. This albumin-derived perfluorocarbon-based artificial oxygen carrier preserved the function of rat hearts due to the transport of oxygen in a satisfactory manner. Because of these positive results, the functionality of the applied capsules should be verified in living animals.
Cook, Jason A.; Shah, Keyur B.; Quader, Mohammed A.; Cooke, Richard H.; Kasirajan, Vigneshwar; Rao, Kris K.; Smallfield, Melissa C.; Tchoukina, Inna
2015-01-01
The total artificial heart (TAH) is a form of mechanical circulatory support in which the patient’s native ventricles and valves are explanted and replaced by a pneumatically powered artificial heart. Currently, the TAH is approved for use in end-stage biventricular heart failure as a bridge to heart transplantation. However, with an increasing global burden of cardiovascular disease and congestive heart failure, the number of patients with end-stage heart failure awaiting heart transplantation now far exceeds the number of available hearts. As a result, the use of mechanical circulatory support, including the TAH and left ventricular assist device (LVAD), is growing exponentially. The LVAD is already widely used as destination therapy, and destination therapy for the TAH is under investigation. While most patients requiring mechanical circulatory support are effectively treated with LVADs, there is a subset of patients with concurrent right ventricular failure or major structural barriers to LVAD placement in whom TAH may be more appropriate. The history, indications, surgical implantation, post device management, outcomes, complications, and future direction of the TAH are discussed in this review. PMID:26793338
... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...
... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...
... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...
Percutaneous dilatational tracheostomy following total artificial heart implantation.
Spiliopoulos, Sotirios; Dimitriou, Alexandros Merkourios; Serrano, Maria Rosario; Guersoy, Dilek; Autschbach, Ruediger; Goetzenich, Andreas; Koerfer, Reiner; Tenderich, Gero
2015-07-01
Coagulation disorders and an immune-altered state are common among total artificial heart patients. In this context, we sought to evaluate the safety of percutaneous dilatational tracheostomy in cases of prolonged need for mechanical ventilatory support. We retrospectively analysed the charts of 11 total artificial heart patients who received percutaneous dilatational tracheostomy. We focused on early and late complications. We observed no major complications and no procedure-related deaths. Early minor complications included venous oozing (45.4%) and one case of local infection. Late complications, including subglottic stenosis, stomal infection or infections of the lower respiratory tract, were not observed. In conclusion, percutaneous dilatational tracheostomy in total artificial heart patients is safe. Considering the well-known benefits of early tracheotomy over prolonged translaryngeal intubation, we advocate early timing of therapy in cases of prolonged mechanical ventilation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
From Phonomecanocardiography to Phonocardiography computer aided
NASA Astrophysics Data System (ADS)
Granados, J.; Tavera, F.; López, G.; Velázquez, J. M.; Hernández, R. T.; López, G. A.
2017-01-01
Due to lack of training doctors to identify many of the disorders in the heart by conventional listening, it is necessary to add an objective and methodological analysis to support this technique. In order to obtain information of the performance of the heart to be able to diagnose heart disease through a simple, cost-effective procedure by means of a data acquisition system, we have obtained Phonocardiograms (PCG), which are images of the sounds emitted by the heart. A program of acoustic, visual and artificial vision recognition was elaborated to interpret them. Based on the results of previous research of cardiologists a code of interpretation of PCG and associated diseases was elaborated. Also a site, within the university campus, of experimental sampling of cardiac data was created. Phonocardiography computer-aided is a viable and low cost procedure which provides additional medical information to make a diagnosis of complex heart diseases. We show some previous results.
Total artificial heart implantation for biventricular failure due to eosinophilic myocarditis.
Kawabori, Masashi; Kurihara, Chitaru; Miller, Yair; Heck, Kent A; Bogaev, Roberta C; Civitello, Andrew B; Cohn, William E; Frazier, O H; Morgan, Jeffrey A
2017-09-01
Idiopathic hypereosinophilic syndrome is a condition of unknown etiology characterized by proliferation of eosinophils and their infiltration into tissues. Although cardiac involvement is rare, eosinophilic myocarditis can lead to life-threating fulminant congestive heart failure. Treatment of patients with eosinophilic myocarditis is challenging as heart failure can be caused by biventricular dysfunction. To our knowledge, this is the first case reported in the literature describing a patient with acute severe biventricular heart failure caused by eosinophilic myocarditis with mural left ventricular apical thrombus who was successfully treated with implantation of a total artificial heart as a bridge to heart transplant.
Testing of Safety-Critical Software Embedded in an Artificial Heart
NASA Astrophysics Data System (ADS)
Cha, Sungdeok; Jeong, Sehun; Yoo, Junbeom; Kim, Young-Gab
Software is being used more frequently to control medical devices such as artificial heart or robotic surgery system. While much of software safety issues in such systems are similar to other safety-critical systems (e.g., nuclear power plants), domain-specific properties may warrant development of customized techniques to demonstrate fitness of the system on patients. In this paper, we report results of a preliminary analysis done on software controlling a Hybrid Ventricular Assist Device (H-VAD) developed by Korea Artificial Organ Centre (KAOC). It is a state-of-the-art artificial heart which completed animal testing phase. We performed software testing in in-vitro experiments and animal experiments. An abnormal behaviour, never detected during extensive in-vitro analysis and animal testing, was found.
Deairing Techniques for Double-Ended Centrifugal Total Artificial Heart Implantation.
Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Grady, Patrick; Sinkewich, Martin; Moazami, Nader; Sale, Shiva; Golding, Leonard A R; Fukamachi, Kiyotaka
2017-06-01
The unique device architecture of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) requires dedicated and specific air-removal techniques during device implantation in vivo. These procedures comprise special surgical techniques and intraoperative manipulations, as well as engineering design changes and optimizations to the device itself. The current study evaluated the optimal air-removal techniques during the Cleveland Clinic double-ended centrifugal CFTAH in vivo implants (n = 17). Techniques and pump design iterations consisted of developing a priming method for the device and the use of built-in deairing ports in the early cases (n = 5). In the remaining cases (n = 12), deairing ports were not used. Dedicated air-removal ports were not considered an essential design requirement, and such ports may represent an additional risk for pump thrombosis. Careful passive deairing was found to be an effective measure with a centrifugal pump of this design. In this report, the techniques and design changes that were made during this CFTAH development program to enable effective residual air removal and prevention of air embolism during in vivo device implantation are explained. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Spiliopoulos, Sotirios; Koerfer, Reiner; Tenderich, Gero
2014-06-01
The SynCardia total artificial heart is currently used as a bridge to transplantation therapy in cases of irreversible, acute or chronic, biventricular heart failure. We describe the implementation of this technology in the context of destination therapy in a patient with an end-stage heart failure on grounds of primary amyloidosis. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Hogan, Matthew; Mohamed, Mohamed; Tao, Ze-Wei; Gutierrez, Laura; Birla, Ravi
2015-02-01
Only 3000 heart transplants are performed in the USA every year, leaving some 30 000-70 000 Americans without proper care. Current treatment modalities for heart failure have saved many lives yet still do not correct the underlying problems of congestive heart failure. Tissue engineering represents a potential field of study wherein a combination of cells, scaffolds, and/or bioreactors can be utilized to create constructs to mimic, replace, and/or repair defective tissue. The focus of this study was to generate a bioartificial heart (BAH) model using artificial heart muscle (AHM), composed of fibrin gel and neonatal rat cardiac myocytes, and a decellularized scaffold, formed by subjecting an adult rat heart to a series of decellularization solutions. By suturing the AHM around the outside of the decellularized heart and culturing while suspended in media, we were able to retain functional cardiac cells on the scaffold as evinced by visible contractility. Observed contractility rate was correlated with biopotential measurements to confirm essential functionality of cardiac constructs. Cross-sections of the BAH show successful decellularization of the scaffold and contiguous cell-rich AHM around the perimeter of the heart. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
1991-01-01
James Antaki and a group of researchers from the University of Pittsburgh School of Medicine used many elements of the Technology Utilization Program while looking for a way to visualize and track material points within the heart muscle. What they needed were tiny artificial "eggs" containing copper sulfate solution, small enough (about 2 mm in diameter) that they would not injure the heart, and large enough to be seen in Magnetic Resonance Imaging (MRI) images; they also had to be biocompatible and tough enough to withstand the beating of the muscle. The group could not make nor buy sufficient containers. After reading an article on microspheres in NASA Tech Briefs, and a complete set of reports on microencapsulation from the Jet Propulsion Laboratory (JPL), JPL put Antaki in touch with Dr.Taylor Wang of Vanderbilt University who helped construct the myocardial markers. The research is expected to lead to improved understanding of how the heart works and what takes place when it fails.
Artificial Respiration and Artificial Circulation
Brook, Joseph; Brook, Morris H.; Lopez, Jose F.
1965-01-01
A training program in the newer methods of treatment of acute cardiopulmonary emergencies which was developed at the University Hospital, University of Saskatchewan, is reported. Artificial respiration by the chance rescuer, primary and secondary resuscitation, and post-resuscitation measures involving the use of special drugs and equipment by trained personnel are described. Figures and tables designed for wall-mounting and ready reference in an emergency situation are presented. Firstaid ventilatory adjuncts for use by trained personnel are classified and critically appraised, and the propriety of their use is emphasized. A plea is made to the medical profession and allied agencies to assume the responsibility of spreading knowledge of the new techniques more widely. Unless effective treatment is instituted early enough to prevent death or permanent anoxic damage to heart and brain, follow-through therapy will often be fruitless. PMID:14339303
Combined heart-kidney transplantation after total artificial heart insertion.
Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F
2015-01-01
We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.
Heart Conditions and Pregnancy: Know the Risks
... threatening infection of the lining of the heart (endocarditis) and heart valves. Mechanical artificial heart valves also ... your baby. If you're at risk of endocarditis, you might receive antibiotic treatment just before and ...
Past and Present of Total Artificial Heart Therapy: A Success Story.
Samak, Mostafa; Fatullayev, Javid; Sabashnikov, Anton; Zeriouh, Mohamed; Rahmanian, Parwis B; Choi, Yeong-Hoon; Wippermann, Jens; Wahlers, Thorsten; Schmack, Bastian; Ruhparwar, Arjang; Dohmen, Pascal M; Karck, Matthias; Popov, Aron-Frederik; Simon, André R; Weymann, Alexander
2015-09-07
The totally artificial heart (TAH) is among the most prominent medical innovations of the 21st century, especially due to the increasing population with end-stage heart failure. The progressive course of the disease, its resistance to conventional therapy, and the scarcity of hearts available for transplantation were the prime impetus for developing a TAH, especially when other options of mechanical circulatory assist devices are exhausted. In this review, we narrate the history of TAH, give an overview of its technology, and address the pros and cons of the currently available TAH models in light of published clinical experience.
If Your Child Has a Heart Defect (For Parents)
... congenital heart disease are at risk for bacterial endocarditis, an infection of the tissue that lines the ... who have artificial heart valves or have had endocarditis before. Most children with heart problems, however, do ...
Perioperative Prophylaxis for Total Artificial Heart Transplantation.
Chambers, H E; Pelish, P; Qiu, F; Florescu, D F
2017-11-01
Practice variation regarding perioperative antimicrobial prophylaxis in total artificial heart transplantations (TAH-t) across institutions is unknown. The aim of our survey was to assess the current practices for prevention of infection in TAH-t recipients among different programs. An electronic survey was sent to programs that implant Syncardia TAH (Syncardia Systems, Tuscon, Ariz, USA). Proportions were analyzed for categorical variables; means and SDs were analyzed for continuous variables. The majority of centers (80.8%) had a formal surgical infection prophylaxis protocol. For non-penicillin-allergic patients, five (20.1%) institutions reported using a 4-drug regimen, seven (29.2%) used a 3-drug regimen, five (20.1%) used a 2-drug regimen, and seven (29.2%) used a cephalosporin alone. Similar data was seen in the penicillin-allergic patients. Infections were reported to occur postoperatively in 52.2% centers. During the first month after TAH-t, bacteremia represented 27.3%, driveline infections 27.2%, pulmonary infections 9%, and mediastinal infections 18.2%. The most common organisms seen within the first month were Candida spp., Escherichia coli, and Pseudomonas aeruginosa (21.4%). In 65% of centers, the mean rate of death post-TAH-t due to infection was 14.5% (SD, 22.3%). The mean rate of patients surviving until orthotopic heart transplantation was 58.6% (SD, 27.7%). Preventing infections post-TAH-t is key to decreasing morbidity and mortality. All institutions administered perioperative prophylaxis for TAH-t with significant variation among the centers. The majority of the centers have a formal perioperative prophylactic protocol. Copyright © 2017. Published by Elsevier Inc.
Novel technique for airless connection of artificial heart to vascular conduits.
Karimov, Jamshid H; Gao, Shengqiang; Dessoffy, Raymond; Sunagawa, Gengo; Sinkewich, Martin; Grady, Patrick; Sale, Shiva; Moazami, Nader; Fukamachi, Kiyotaka
2017-12-01
Successful implantation of a total artificial heart relies on multiple standardized procedures, primarily the resection of the native heart, and exacting preparation of the atrial and vascular conduits for pump implant and activation. Achieving secure pump connections to inflow/outflow conduits is critical to a successful outcome. During the connection process, however, air may be introduced into the circulation, traveling to the brain and multiple organs. Such air emboli block blood flow to these areas and are detrimental to long-term survival. A correctly managed pump-to-conduit connection prevents air from collecting in the pump and conduits. To further optimize pump-connection techniques, we have developed a novel connecting sleeve that enables airless connection of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) to the conduits. In this brief report, we describe the connecting sleeve design and our initial results from two acute in vivo implantations using a scaled-down version of the CFTAH.
Application of Artificial Neural Networks in the Heart Electrical Axis Position Conclusion Modeling
NASA Astrophysics Data System (ADS)
Bakanovskaya, L. N.
2016-08-01
The article touches upon building of a heart electrical axis position conclusion model using an artificial neural network. The input signals of the neural network are the values of deflections Q, R and S; and the output signal is the value of the heart electrical axis position. Training of the network is carried out by the error propagation method. The test results allow concluding that the created neural network makes a conclusion with a high degree of accuracy.
Total Artificial Heart Implantation after Excision of Right Ventricular Angiosarcoma.
Bruckner, Brian A; Abu Saleh, Walid K; Al Jabbari, Odeaa; Copeland, Jack G; Estep, Jerry D; Loebe, Matthias; Reardon, Michael J
2016-06-01
Primary cardiac sarcomas, although rare, are aggressive and lethal, requiring thorough surgical resection and adjuvant chemotherapy for the best possible outcome. We report the case of a 32-year-old woman who underwent total artificial heart implantation for right-sided heart failure caused by right ventricular angiosarcoma. For the first several weeks in intensive care, the patient recovered uneventfully. However, a postoperative liver biopsy indicated hepatocellular injury consistent with preoperative chemotherapy. She developed continuing liver failure, from which she died despite good cardiac function.
Reich, H; Czer, L; Bannykh, S; De Robertis, M; Wolin, E; Amersi, F; Moriguchi, J; Kobashigawa, J; Arabia, F
2015-09-01
Malignancy is the leading cause of long-term morbidity and mortality after heart and other solid organ transplantation; therefore, great emphasis is placed on pre- and post-transplantation cancer screening. Even with meticulous screening during evaluation for heart transplant candidacy, an occult cancer may not be apparent. Here, we share the case of a 51-year-old man with refractory heart failure who underwent total artificial heart implantation as a bridge to transplantation with the surprise finding of an isolated deposit of metastatic carcinoid tumor nested within a left ventricular papillary muscle in his explanted heart. The primary ileal carcinoid tumor was identified and resected completely. After remaining cancer-free for 14 months, he was listed for heart transplantation and was transplanted 2 months later. He is currently 3.5 months out from heart transplantation and doing well, without evidence of recurring malignancy. Copyright © 2015 Elsevier Inc. All rights reserved.
Willem J Kolff (1911-2009): physician, inventor and pioneer: father of artificial organs.
Morrissey, Megan
2012-08-01
Medical pioneer Willem Johan Kolff was an inspirational father, son, physician and inventor. He founded the development of the first kidney dialysis machine, pioneered advances in the heart and lung machine, laid down the foundations for the first mainland blood bank in Europe and successfully implanted the first artificial heart into humans.
ERIC Educational Resources Information Center
Bramstedt, Katrina A.
2004-01-01
Total artificial heart technology as a potential clinical therapy raises the issue of elective device inactivation in both futile and non-futile situations. This article explores elective device inactivation in non-futile situations. In reply to such requests for inactivation, the medical team should reflect on the individual's decision-making…
Khalpey, Zain; Kazui, Toshinobu; Ferng, Alice S; Connell, Alana; Tran, Phat L; Meyer, Mark; Rawashdeh, Badi; Smith, Richard G; Sweitzer, Nancy K; Friedman, Mark; Lick, Scott; Slepian, Marvin J; Copeland, Jack G
2016-01-01
The 70 cc total artificial heart (TAH) has been utilized as bridge to transplant (BTT) for biventricular failure. However, the utilization of 70 cc TAH has been limited to large patients for the low output from the pulmonary as well as systemic vein compression after chest closure. Therefore, the 50 cc TAH was developed by SynCardia (Tucson, AZ) to accommodate smaller chest cavity. We report the first TAH exchange from a 70 to 50 cc due to a fit difficulty. The patient failed to be closed with a 70 cc TAH, although the patient met the conventional 70 cc TAH fit criteria. We successfully closed the chest with a 50 cc TAH.
An original valveless artificial heart providing pulsatile flow tested in mock circulatory loops.
Tozzi, Piergiorgio; Maertens, Audrey; Emery, Jonathan; Joseph, Samuel; Kirsch, Matthias; Avellan, François
2017-11-24
We present the test bench results of a valveless total artificial heart that is potentially compatible with the pediatric population. The RollingHeart is a valveless volumetric pump generating pulsatile flow. It consists of a single spherical cavity divided into 4 chambers by 2 rotating disks. The combined rotations of both disks produce changes in the volumes of the 4 cavities (suction and ejection). The blood enters/exits the spherical cavity through 4 openings that are symmetrical to the fixed rotation axis of the first disk.Mock circulatory system: The device pumps a 37% glycerin solution through 2 parallel circuits, simulating the pulmonary and systemic circulations. Flow rates are acquired with a magnetic inductive flowmeter, while pressure sensors collect pressure in the left and right outflow and inflow tracts.In vitro test protocol: The pump is run at speeds ranging from 20 to 180 ejections per minute. The waveform of the pressure generated at the inflow and outflow of the 4 chambers and the flow rate in the systemic circulation are measured. At an ejection rate of 178 min-1, the RollingHeart pumps 5.3 L/min for a systemic maximal pressure gradient of 174 mmHg and a pulmonary maximal pressure gradient of 75 mmHg. The power input was 14 W, corresponding to an efficiency of 21%. The RollingHeart represents a new approach in the domain of total artificial heart. This preliminary study endorses the feasibility of a single valveless device acting as a total artificial heart.
Machines versus medication for biventricular heart failure: focus on the total artificial heart.
Arabia, Francisco A; Moriguchi, Jaime D
2014-09-01
The medical/surgical management of advanced heart failure has evolved rapidly over the last few decades. With better understanding of heart failure pathophysiology, new pharmacological agents have been introduced that have resulted in improvements in survival. For those patients that fail to improve, mechanical circulatory support with left ventricular assist devices and total artificial hearts (TAHs) have served as a beneficial bridge to transplantation. The TAH has continued to play a significant role as a bridge to transplantation in patients with biventricular failure and more selected indications that could not be completely helped with left ventricular assist devices. Improved survival with the TAH has resulted in more patients benefiting from this technology. Improvements will eventually lead to a totally implantable device that will permanently replace the failing human heart.
System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.
Pelletier, Benedikt; Spiliopoulos, Sotirios; Finocchiaro, Thomas; Graef, Felix; Kuipers, Kristin; Laumen, Marco; Guersoy, Dilek; Steinseifer, Ulrich; Koerfer, Reiner; Tenderich, Gero
2015-01-01
Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Past and Present of Total Artificial Heart Therapy: A Success Story
Samak, Mostafa; Fatullayev, Javid; Sabashnikov, Anton; Zeriouh, Mohamed; Rahmanian, Parwis B.; Choi, Yeong-Hoon; Wippermann, Jens; Wahlers, Thorsten; Schmack, Bastian; Ruhparwar, Arjang; Dohmen, Pascal M.; Karck, Matthias; Popov, Aron-Frederik; Simon, André R.; Weymann, Alexander
2015-01-01
The totally artificial heart (TAH) is among the most prominent medical innovations of the 21st century, especially due to the increasing population with end-stage heart failure. The progressive course of the disease, its resistance to conventional therapy, and the scarcity of hearts available for transplantation were the prime impetus for developing a TAH, especially when other options of mechanical circulatory assist devices are exhausted. In this review, we narrate the history of TAH, give an overview of its technology, and address the pros and cons of the currently available TAH models in light of published clinical experience. PMID:26343363
Physiological Characterization of the SynCardia Total Artificial Heart in a Mock Circulation System
Crosby, Jessica R.; DeCook, Katrina J.; Tran, Phat L.; Smith, Richard G.; Larson, Douglas F.; Khalpey, Zain I.; Burkhoff, Daniel; Slepian, Marvin J.
2014-01-01
The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving bi-ventricular replacement system for a wide variety of patients with end-stage heart failure. While the clinical performance of the TAH is established, modern physiologic characterization, in terms of elastance behavior and pressure-volume characterization has not been defined. Herein we examine the TAH in terms of elastance using a non-ejecting left-ventricle, and then characterize the pressure-volume relationship of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Further, we show that the TAH has a pressure-volume relationship behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload, however this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared to the human heart. PMID:25551416
Physiological characterization of the SynCardia total artificial heart in a mock circulation system.
Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J
2015-01-01
The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving biventricular replacement system for a wide variety of patients with end-stage heart failure. Although the clinical performance of the TAH is established, modern physiological characterization, in terms of elastance behavior and pressure-volume (PV) characterization has not been defined. Herein, we examine the TAH in terms of elastance using a nonejecting left ventricle, and then characterize the PV relation of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Furthermore, we show that the TAH has a PV relation behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload-dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload; however, this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared with the human heart.
... may be able to replace it with an artificial (man-made) valve. Cardiac size reduction . During this procedure, your doctor removes a piece of the heart muscle from an enlarged heart. This makes your ...
Raguin, Thibaut; Dupret-Bories, Agnès; Debry, Christian
2017-01-01
Research has been fighting against organ failure and shortage of donations by supplying artificial organs for many years. With the raise of new technologies, tissue engineering and regenerative medicine, many organs can benefit of an artificial equivalent: thanks to retinal implants some blind people can visualize stimuli, an artificial heart can be proposed in case of cardiac failure while awaiting for a heart transplant, artificial larynx enables laryngectomy patients to an almost normal life, while the diabetic can get a glycemic self-regulation controlled by smartphones with an artificial device. Dialysis devices become portable, as well as the oxygenation systems for terminal respiratory failure. Bright prospects are being explored or might emerge in a near future. However, the retrospective assessment of putative side effects is not yet sufficient. Finally, the cost of these new devices is significant even if the advent of three dimensional printers may reduce it. © 2017 médecine/sciences – Inserm.
Artificial heart development program. Volume I. System development. Phase III summary report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1977-01-01
The report documents efforts and results in the development of the power system portions of a calf implantable model of nuclear-powered artificial heart. The primary objective in developing the implantable model was to solve the packaging problems for total system implantation. The power systems portion is physically that portion of the implantable model between the Pu-238 heat sources and the blood pump ventricles. The work performed had two parallel themes. The first of these was the development of an integrated implantable model for bench and animal experiments plus design effort on a more advanced model. The second was research andmore » development on components of the system done in conjunction with the development of the implantable model and to provide technology for incorporation into advanced models plus support to implantations, at the University of Utah, of the systems blood pumping elements when driven by electric motor. The efforts and results of implantable model development are covered, mainly, in the text of the report. The research and development efforts and results are reported, primarily, in the appendices (Vol. 2).« less
Yamamoto, Takahiko; Koshiji, Kohji; Homma, Akihiko; Tatsumi, Eisuke; Taenaka, Yoshiyuki
2008-01-01
Transcutaneous energy transmission (TET) that uses electromagnetic induction between the external and internal coils of a transformer is the most promising method to supply driving energy to a totally implantable artificial heart without invasion. Induction-heating (IH) cookers generate magnetic flux, and if a cooker is operated near a transcutaneous transformer, the magnetic flux generated will link with the external and internal coils of the transcutaneous transformer. This will affect the performance of the TET and the artificial heart system. Hence, it is necessary to improve the magnetic field immunity of the TET system. During operation of the system, if the transcutaneous transformer is in close proximity to an IH cooker, the electric power generated by the cooker and coupled to the transformer can drive the artificial heart system. To prevent this coupling, the external coil was shielded with a conductive shield that had a slit in it. This reduces the coupling between the transformer and the magnetic field generated by the induction cooker. However, the temperature of the shield increased due to heating by eddy currents. The temperature of the shield can be reduced by separating the IH cooker and the shield.
Numerical Simulation of Flow Through an Artificial Heart
NASA Technical Reports Server (NTRS)
Rogers, Stuart E.; Kutler, Paul; Kwak, Dochan; Kiris, Cetin
1989-01-01
A solution procedure was developed that solves the unsteady, incompressible Navier-Stokes equations, and was used to numerically simulate viscous incompressible flow through a model of the Pennsylvania State artificial heart. The solution algorithm is based on the artificial compressibility method, and uses flux-difference splitting to upwind the convective terms; a line-relaxation scheme is used to solve the equations. The time-accuracy of the method is obtained by iteratively solving the equations at each physical time step. The artificial heart geometry involves a piston-type action with a moving solid wall. A single H-grid is fit inside the heart chamber. The grid is continuously compressed and expanded with a constant number of grid points to accommodate the moving piston. The computational domain ends at the valve openings where nonreflective boundary conditions based on the method of characteristics are applied. Although a number of simplifing assumptions were made regarding the geometry, the computational results agreed reasonably well with an experimental picture. The computer time requirements for this flow simulation, however, are quite extensive. Computational study of this type of geometry would benefit greatly from improvements in computer hardware speed and algorithm efficiency enhancements.
Eslamizadeh, Gholamhossein; Barati, Ramin
2017-05-01
Early recognition of heart disease plays a vital role in saving lives. Heart murmurs are one of the common heart problems. In this study, Artificial Neural Network (ANN) is trained with Modified Neighbor Annealing (MNA) to classify heart cycles into normal and murmur classes. Heart cycles are separated from heart sounds using wavelet transformer. The network inputs are features extracted from individual heart cycles, and two classification outputs. Classification accuracy of the proposed model is compared with five multilayer perceptron trained with Levenberg-Marquardt, Extreme-learning-machine, back-propagation, simulated-annealing, and neighbor-annealing algorithms. It is also compared with a Self-Organizing Map (SOM) ANN. The proposed model is trained and tested using real heart sounds available in the Pascal database to show the applicability of the proposed scheme. Also, a device to record real heart sounds has been developed and used for comparison purposes too. Based on the results of this study, MNA can be used to produce considerable results as a heart cycle classifier. Copyright © 2017 Elsevier B.V. All rights reserved.
[Heart transplantation and long-term lvad support cost-effectiveness model].
Szentmihályi, Ilona; Barabás, János Imre; Bali, Ágnes; Kapus, Gábor; Tamás, Csilla; Sax, Balázs; Németh, Endre; Pólos, Miklós; Daróczi, László; Kőszegi, Andrea; Cao, Chun; Benke, Kálmán; Kovács, Péter Barnabás; Fazekas, Levente; Szabolcs, Zoltán; Merkely, Béla; Hartyánszky, István
2016-12-01
Heart transplantation is a high priority project at Semmelweis University. In accordance with this, the funding of heart transplantation and mechanical circulatory support also constitutes an important issue. In this report, the authors discuss the creation of a framework with the purpose of comparing the cost-effectiveness of heart transplantation and artificial heart implantation. Our created framework includes the calculation of cost, using the direct allocation method, calculating the incremental cost-effectiveness ratio and creating a cost-effectiveness plane. Using our model, it is possible to compare the initial, perioperative and postoperative expenses of both the transplanted and the artificial heart groups. Our framework can possibly be used for the purposes of long term follow-up and with the inclusion of a sufficient number of patients, the creation of cost-effectiveness analyses and supporting strategic decision-making.
Raia, Federica; Deng, Mario C
2017-01-01
In the US population of 300 million, 3 million have heart failure with reduced ejection fraction and 300,000 have advanced heart failure. Long-term mechanical circulatory support will, within the next decade, be recommended to 30,000 patients annually in the USA, 3000 undergo heart transplantation annually. What do these advances mean for persons suffering from advanced heart failure and their loved ones/caregivers? In this perspective article, we discuss - by exemplifying a case report of a 27-year-old man receiving a Total Artificial Heart - a practice concept of modern medicine that fully incorporates the patient's personhood perspective which we have termed Relational Medicine™. From this case study, it becomes apparent that the successful practice of modern cardiovascular medicine requires the person-person encounter as a core practice element.
ERIC Educational Resources Information Center
Brock, David
2009-01-01
Despite student interest, the heart is often a poorly understood topic in biology. To help students understand this vital organ's physiology, the author created this investigation activity involving the mammalian heart and its role in the circulatory system. Students design, build, and demonstrate working artificial "hearts" to exhibit what they…
An electric artificial heart for clinical use.
Pierce, W S; Rosenberg, G; Snyder, A J; Pae, W E; Donachy, J H; Waldhausen, J A
1990-01-01
Advances in microelectronics, high-strength magnets, and control system design now make replacement of the heart using an implantable, electrically powered pump feasible. The device described herein is a compact, dual pusher plate unit with valved polyurethane sac-type ventricles positioned at either end. The power unit consists of a small, brushless direct current motor and a motion translator. A microprocessor control system is used to regulate heart beat rate and provide left-right output balance. Bench studies lasting for as long as 1 year have been performed. Heart replacement with the electric heart has been performed in 18 calves since 1984. The longest survivor lived for more than 7 months. Among the causes of termination were component failure, thromboembolic complications, and bleeding. No major problem has been identified that precludes prolonged use of the electric heart. In the future the patient with end-stage heart disease will have an electric artificial heart as one therapeutic option. Images Figs. 1A and 1B. Fig. 3. Fig. 5. PMID:2396885
Youdle, Jemma; Penn, Sarah; Maunz, Olaf; Simon, Andre
2017-01-01
We report our first clinical use of the new Protek Duo TM cannula for peripheral veno-venous extra-corporeal life support (ECLS). A 53-year-old male patient underwent implantation of a total artificial heart (TAH) for biventricular failure. However, due to the development of post-operative respiratory dysfunction, the patient required ECLS for six days.
[Multi-channel data collection and visualization system for intramyocardial electrograms].
Kastner, P; Wimmer, W; Hutten, H
2000-11-01
The aim of the project was to develop a multichannel data acquisition system for the recording and visualisation of intramyocardial electrograms (IEGM) from both the spontaneously beating and the artificially paced heart. Signal processing comprises multi-step amplification, filtering (0.05-800 Hz), and AD conversion (12 Bit max. 6.25 kHz). IEGMs can be obtained either in unipolar or bipolar mode. Stimulation of the heart is achieved by an incorporated programmable dual-chamber pacemaker that can be selectively switched to the input channels. A LabView-based graphical user interface permits the programming of all system parameters via a microcontroller, and supports data acquisition and visualisation. The system can be used in animal experiments to monitor the spread of excitation across the heart, to measure propagation velocity, or to measure the impact of drugs and pathological changes on the morphology of IEGMs.
A Soft Total Artificial Heart-First Concept Evaluation on a Hybrid Mock Circulation.
Cohrs, Nicholas H; Petrou, Anastasios; Loepfe, Michael; Yliruka, Maria; Schumacher, Christoph M; Kohll, A Xavier; Starck, Christoph T; Schmid Daners, Marianne; Meboldt, Mirko; Falk, Volkmar; Stark, Wendelin J
2017-10-01
The technology of 3D-printing has allowed the production of entirely soft pumps with complex chamber geometries. We used this technique to develop a completely soft pneumatically driven total artificial heart from silicone elastomers and evaluated its performance on a hybrid mock circulation. The goal of this study is to present an innovative concept of a soft total artificial heart (sTAH). Using the form of a human heart, we designed a sTAH, which consists of only two ventricles and produced it using a 3D-printing, lost-wax casting technique. The diastolic properties of the sTAH were defined and the performance of the sTAH was evaluated on a hybrid mock circulation under various physiological conditions. The sTAH achieved a blood flow of 2.2 L/min against a systemic vascular resistance of 1.11 mm Hg s/mL (afterload), when operated at 80 bpm. At the same time, the mean pulmonary venous pressure (preload) was fixed at 10 mm Hg. Furthermore, an aortic pulse pressure of 35 mm Hg was measured, with a mean aortic pressure of 48 mm Hg. The sTAH generated physiologically shaped signals of blood flow and pressures by mimicking the movement of a real heart. The preliminary results of this study show a promising potential of the soft pumps in heart replacements. Further work, focused on increasing blood flow and in turn aortic pressure is required. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Wyller, Vegard Bruun; Aaberge, Lars; Thaulow, Erik; Døhlen, Gaute
2011-07-01
Percutaneous catheter-based implantation of artificial heart valves is a new technique that may supplement surgery and which may be used more in the future. We here report our first experience with implantation of artificial pulmonary valves in children with congenital heart defects. Eligible patients were those with symptoms of heart failure combined with stenosis and/or insufficiency in an established artificial right ventricular outflow tract. The valve was inserted through a catheter from a vein in the groin or neck. Symptoms, echocardiography, invasive measurements and angiography were assessed for evaluation of treatment effect. Our treatment results are reported for the period April 2007-September 2009. Ten patients (seven men and three women, median age 17 years) were assessed. The procedure reduced pressure in the right ventricle (p = 0.008) and resolved the pulmonary insufficiency in all patients. The median time in hospital was two days. No patients had complications that were directly associated with the implantation procedure. One patient developed a pseudoaneurysm in the femoral artery, another had a short-lasting fever two days after the procedure and one patient experienced a stent fracture that required surgery 9 months after the implantation. After 6 months all patients had a reduced pressure gradient in the right ventricular outflow tract (p = 0.008), the pulmonary insufficiency had improved (p = 0.006) and they all reported improval of symptoms. These results persisted for at least 24 months for the four patients who were monitored until then. Percutaneous catheter-based implantation of artificial pulmonary valves improves hemodynamics in the right ventricle of selected patients with congenital heart defects. A randomized controlled study should be undertaken to provide a stronger evidence-base for usefulness of this procedure.
NASA Astrophysics Data System (ADS)
Sonntag, Simon J.; Kaufmann, Tim A. S.; Büsen, Martin R.; Laumen, Marco; Linde, Torsten; Schmitz-Rode, Thomas; Steinseifer, Ulrich
2013-04-01
Heart disease is one of the leading causes of death in the world. Due to a shortage in donor organs artificial hearts can be a bridge to transplantation or even serve as a destination therapy for patients with terminal heart insufficiency. A pusher plate driven pulsatile membrane pump, the Total Artificial Heart (TAH) ReinHeart, is currently under development at the Institute of Applied Medical Engineering of RWTH Aachen University.This paper presents the methodology of a fully coupled three-dimensional time-dependent Fluid Structure Interaction (FSI) simulation of the TAH using a commercial partitioned block-Gauss-Seidel coupling package. Partitioned coupling of the incompressible fluid with the slender flexible membrane as well as a high fluid/structure density ratio of about unity led inherently to a deterioration of the stability (‘artificial added mass instability’). The objective was to conduct a stable simulation with high accuracy of the pumping process. In order to achieve stability, a combined resistance and pressure outlet boundary condition as well as the interface artificial compressibility method was applied. An analysis of the contact algorithm and turbulence condition is presented. Independence tests are performed for the structural and the fluid mesh, the time step size and the number of pulse cycles. Because of the large deformation of the fluid domain, a variable mesh stiffness depending on certain mesh properties was specified for the fluid elements. Adaptive remeshing was avoided. Different approaches for the mesh stiffness function are compared with respect to convergence, preservation of mesh topology and mesh quality. The resulting mesh aspect ratios, mesh expansion factors and mesh orthogonalities are evaluated in detail. The membrane motion and flow distribution of the coupled simulations are compared with a top-view recording and stereo Particle Image Velocimetry (PIV) measurements, respectively, of the actual pump.
The Total Artificial Heart in End-Stage Congenital Heart Disease.
Villa, Chet R; Morales, David L S
2017-01-01
The development of durable ventricular assist devices (VADs) has improved mortality rates and quality of life in patients with end stage heart failure. While the use of VADs has increased dramatically in recent years, there is limited experience with VAD implantation in patients with complex congenital heart disease (CHD), despite the fact that the number of patients with end stage CHD has grown due to improvements in surgical and medical care. VAD use has been limited in patients with CHD and end stage heart failure due to anatomic (systemic right ventricle, single ventricle, surgically altered anatomy, valve dysfunction, etc.) and physiologic constraints (diastolic dysfunction). The total artificial heart (TAH), which has right and left sided pumps that can be arranged in a variety of orientations, can accommodate the anatomic variation present in CHD patients. This review provides an overview of the potential use of the TAH in patients with CHD.
The Total Artificial Heart in End-Stage Congenital Heart Disease
Villa, Chet R.; Morales, David L. S.
2017-01-01
The development of durable ventricular assist devices (VADs) has improved mortality rates and quality of life in patients with end stage heart failure. While the use of VADs has increased dramatically in recent years, there is limited experience with VAD implantation in patients with complex congenital heart disease (CHD), despite the fact that the number of patients with end stage CHD has grown due to improvements in surgical and medical care. VAD use has been limited in patients with CHD and end stage heart failure due to anatomic (systemic right ventricle, single ventricle, surgically altered anatomy, valve dysfunction, etc.) and physiologic constraints (diastolic dysfunction). The total artificial heart (TAH), which has right and left sided pumps that can be arranged in a variety of orientations, can accommodate the anatomic variation present in CHD patients. This review provides an overview of the potential use of the TAH in patients with CHD. PMID:28536530
Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Betterton, Edward; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J
2017-07-01
With the growth and diversity of mechanical circulatory support (MCS) systems entering clinical use, a need exists for a robust mock circulation system capable of reliably emulating and reproducing physiologic as well as pathophysiologic states for use in MCS training and inter-device comparison. We report on the development of such a platform utilizing the SynCardia Total Artificial Heart and a modified Donovan Mock Circulation System, capable of being driven at normal and reduced output. With this platform, clinically relevant heart failure hemodynamics could be reliably reproduced as evidenced by elevated left atrial pressure (+112%), reduced aortic flow (-12.6%), blunted Starling-like behavior, and increased afterload sensitivity when compared with normal function. Similarly, pressure-volume relationships demonstrated enhanced sensitivity to afterload and decreased Starling-like behavior in the heart failure model. Lastly, the platform was configured to allow the easy addition of a left ventricular assist device (HeartMate II at 9600 RPM), which upon insertion resulted in improvement of hemodynamics. The present configuration has the potential to serve as a viable system for training and research, aimed at fostering safe and effective MCS device use. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Wróbel, Krzysztof; Kurnicka, Katarzyna; Zygier, Marcin; Dyk, Wojciech; Wojdyga, Ryszard; Zieliński, Dariusz; Jarzębska, Małgorzata; Juraszyński, Zbigniew; Lichodziejewska, Barbara; Pruszczyk, Piotr; Biederman, Andrzej; Speziali, Giovanni; Kasten, Uwe
2017-01-01
Artificial chord implantation to repair a flail or prolapsing mitral valve leaflet requires open heart surgery and cardiopulmonary bypass. Transapical off-pump artificial chordae implantation is a new surgical technique proposed to treat degenerative mitral valve regurgitation. The procedure is performed using the NeoChord DS1000 system (NeoChord, Inc., St. Louis Park, MN, USA), which facilitates both implantation and lenght adjustment of the artificial chordae under two (2D)- and three (3D)-dimensional transoesophageal echocardiographic (TEE) guidance on a beating heart. Two male patients aged 60 and 55 years with severe mitral regurgitation due to posterior leaflet prolapse underwent transapical off-pump artificial chordae implantation on September 3, 2015. The procedure was performed by left minithoracotomy under general anaesthesia in a cardiac surgical theatre, using 2D and 3D TEE guidance. Early procedural success as confirmed by 3D TEE was achieved in both patients, with implantation of 6 artificial chordae in the first patient and 3 artificial chordae in the second patient. Both procedures were uneventful, and no postoperative complications were noted. The patients were discharged home on the 8th and 6th postoperative day, respectively. The NeoChord DS1000 system allows both implantation and lenght adjustment of artificial chordae under 2D and 3D TEE guidance on a beating heart. Our initial experience in 2 patients with posterior mitral leaflet prolapse indicates that the procedure is feasible and safe.
Worldwide Experience with the Syncardia Total Artificial Heart in the Pediatric Population.
Morales, David L S; Lorts, Angela; Rizwan, Raheel; Zafar, Farhan; Arabia, Francisco A; Villa, Chet R
Individual centers have documented the use of the Syncardia Total Artificial Heart (TAH) in adolescents with heart failure; however, the number of patients at any given center is small. Herein, we describe the worldwide experience for all patients ≤21 years old supported with the TAH between May 2005 and May 2015 (n = 43). The number of patients experiencing a positive outcome at 60, 90, and 120 days were 30 (70%), 27 (63%), and 25 (58%), respectively. Successful bridge to transplantation varied by diagnosis, but outcomes reported are similar to adults supported with the TAH or biventricular assist devices.
Further evidence of gaseous embolic material in patients with artificial heart valves.
Georgiadis, D; Baumgartner, R W; Karatschai, R; Lindner, A; Zerkowski, H R
1998-04-01
We undertook this study to evaluate the hypothesis that most microemboli signals in patients with artificial heart valves are gaseous, assuming that microemboli counts in cerebral arteries would progressively decline with increasing distance from the generating heart valve. A total of 10 outpatients with CarboMedics (Sulzer Carbomedics Inc., n = 5) and ATS prosthetic heart valves (n = 5) in the aortic (n = 8), mitral (n = 1), or both aortic and mitral positions (n = 1) were recruited. Monitoring was performed simultaneously over the middle and anterior cerebral arteries and the common carotid artery for 30 minutes with the 2 MHZ transducers of a color duplex scanner (common carotid artery) and pulsed-wave Doppler ultrasonography (intracranial arteries). All data were harvested in an eight-channel digital audio tape recorder, and microembolic signal counts were evaluated online by two separate observers. Significantly higher microembolic signal counts were recorded in the common carotid artery (112 [75 to 175]) compared with the middle and anterior cerebral arteries (30 [18 to 36], p < 0.0001). Interobserver variability was satisfactory (k = 0.81). Our results strongly argue for gaseous underlying embolic material in patients with artificial heart valves because bubbles are bound to implode with time.
Sudden death of a middle-aged man with an artificial vagina in situ.
Vidanapathirana, Muditha; Ruwanpura, Rohan P; Amararatne, Sriyantha Rrg
2016-01-01
Artificial vaginas are designed to imitate the female sex organ. This is the first reported case in the forensic literature of a man being pronounced dead with an artificial vagina in situ . A middle-aged man was found unconscious in a bathroom when the door was forced open and was pronounced dead on admission. Autopsy revealed that the penis was inside an artificial vagina. There were no injuries, but there were left ventricular hypertrophy, myocardial fibrosis, and narrow coronaries. The cause of death was ascertained as ischemic heart disease due to coronary atherosclerosis and the comments included were no evidence of violence, and ischemic heart disease could have been precipitated due to abnormal sexual activity. If removal of artificial vagina was done before the admission, this circumstance could not have ascertained. Removal of such devices before admission to hospitals could be the reason why such incidents do not come to light.
The total artificial heart for biventricular heart failure and beyond.
Kasirajan, Vigneshwar; Tang, Daniel G; Katlaps, Gundars J; Shah, Keyur B
2012-05-01
Treatment options for late-stage biventricular heart failure are limited but include medical therapy with intravenous inotropes, biventricular assist devices (Bi-VADs) and the total artificial heart (TAH). In this manuscript, we review the indications, surgical techniques and outcomes for the TAH. The TAH offers biventricular replacement, rather than 'assistance', as the device is placed orthotopically after excision of the entire ventricular myocardium and all four native valves. In contrast to patients with Bi-VADs, patients with the TAH have no postoperative inotrope requirements, arrhythmias or inflow/outflow cannulae-related complications. Additionally, patients participate in rehabilitation early after device placement and the development of a portable drive may facilitate hospital discharge in the USA. Furthermore, total heart replacement may be ideal for heart failure associated with unique anatomical and mechanical complications. The TAH is an effective therapeutic option for the treatment of patients dying of heart failure who may not be suitable candidates for left ventricular assist devices.
... the head; MRI - cranial; NMR - cranial; Cranial MRI; Brain MRI; MRI - brain; MRI - head ... the test, tell your provider if you have: Brain aneurysm clips An artificial heart valves Heart defibrillator ...
Implantation technique of the 50-cm3 SynCardia Total Artificial Heart: does size make a difference?
Spiliopoulos, Sotirios; Guersoy, Dilek; Dimitriou, Alexandros Merkourios; Koerfer, Reiner; Tenderich, Gero
2015-01-01
Despite downsizing, implantation technique of the 50-cm(3) SynCardia Total Artificial Heart and settings of the Companion driver remain unchanged. Owing to the absence of de-airing nipples, de-airing procedure is even more crucial and has to be performed carefully. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Design of a portable artificial heart drive system based on efficiency analysis.
Kitamura, T
1986-11-01
This paper discusses a computer simulation of a pneumatic portable piston-type artificial heart drive system with a linear d-c-motor. The purpose of the design is to obtain an artificial heart drive system with high efficiency and small dimensions to enhance portability. The design employs two factors contributing the total efficiency of the drive system. First, the dimensions of the pneumatic actuator were optimized under a cost function of the total efficiency. Second, the motor performance was studied in terms of efficiency. More than 50 percent of the input energy of the actuator with practical loads is consumed in the armature circuit in all linear d-c-motors with brushes. An optimal design is: the piston cross-sectional area of 10.5 cm2 cylinder longitudinal length of 10 cm. The total efficiency could be up to 25 percent by improving the gasket to reduce the frictional force.
Liver failure in total artificial heart therapy.
Dimitriou, Alexandros Merkourios; Dapunt, Otto; Knez, Igor; Wasler, Andrae; Oberwalder, Peter; Koerfer, Reiner; Tenderich, Gero; Spiliopoulos, Sotirios
2016-07-01
Congestive hepatopathy (CH) and acute liver failure (ALF) are common among biventricular heart failure patients. We sought to evaluate the impact of total artificial heart (TAH) therapy on hepatic function and associated clinical outcomes. A total of 31 patients received a Syncardia Total Artificial Heart. Preoperatively 17 patients exhibited normal liver function or mild hepatic derangements that were clinically insignificant and did not qualify as acute or chronic liver failure, 5 patients exhibited ALF and 9 various hepatic derangements owing to CH. Liver associated mortality and postoperative course of liver values were prospectively documented and retrospectively analyzed. Liver associated mortality in normal liver function, ALF and CH cases was 0%, 20% (P=0.03) and 44.4% (P=0.0008) respectively. 1/17 (5.8%) patients with a normal liver function developed an ALF, 4/5 (80%) patients with an ALF experienced a markedly improvement of hepatic function and 6/9 (66.6%) patients with CH a significant deterioration. TAH therapy results in recovery of hepatic function in ALF cases. Patients with CH prior to surgery form a high risk group with increased liver associated mortality.
Nishida, Masahiro
2017-09-01
This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2015 (Vol.44, No. 3, pp.130-135), with some modifications regarding several references published in 2015 or later.
Improvement on the auxiliary total artificial heart (ATAH) left chamber design.
Andrade, Aron; Fonseca, Jeison; Legendre, Daniel; Nicolosi, Denys; Biscegli, Jose; Pinotti, Marcos; Ohashi, Yukio; Nosé, Yukihiko
2003-05-01
The auxiliary total artificial heart (ATAH) is an electromechanically driven artificial heart with reduced dimensions, which is able to be implanted in the right thoracic or abdominal cavities of an average human patient without removing the natural heart or the heart neurohumoral inherent control mechanism for the arterial pressure. This device uses a brushless direct current motor and a mechanical actuator (roller screw) to move two diaphragms. The ATAH's beating frequency is regulated through the change of the left preload, based on Frank-Starling's law, assisting the native heart in obtaining adequate blood flow. The ATAH left and right stroke volumes are 38 ml and 34 ml, respectively, giving approximately 5 L/min of cardiac output at 160 bpm. Flow visualization studies were performed in critical areas on the ATAH left chamber. A closed circuit loop was used with water and glycerin (37%) at 25 degrees C. Amberlite particles (80 mesh) were illuminated by a 1 mm planar helium-neon laser light. With left mean preload fixed at 10 mm Hg and the afterload at 100 mm Hg, the heart rate varied from 60 to 200 bpm. Two porcine valves were used on the inlet and outlet ports. The flow pattern images were obtained using a color micro-camera and a video recorder. Subsequently, these images were digitized using a PC computer. A persistent stagnant flow was detected in the left chamber inlet port. After improvement on the left chamber design, this stagnant flow disappeared.
Scully, Michael S; Wessman, Dylan E; McKee, James M; Francisco, Gregory M; Nayak, Keshav R; Kobashigawa, Jon A
2017-03-01
Cardiac involvement by light-chain (AL) amyloid occurs in up to 50% of patients with primary AL amyloidosis. The prognosis of amyloid heart disease is poor with 1-year survival rates of 35 to 40%. Historically, heart transplantation was considered controversial for patients with AL amyloid cardiomyopathy (CM) given the systemic nature of the disease and poor survival. We present a case report of an active duty service member diagnosed with advanced cardiac amyloid who underwent total artificial heart transplant as a bridge to heart transplant and eventual autologous stem cell transplant. A 47-year-old active duty male initially evaluated for atypical chest pain was found to have severe concentric left ventricular hypertrophy on echocardiogram but normal voltage on electrocardiogram. Cardiac magnetic resonance imaging, laboratory studies, and bone marrow biopsy established the diagnosis of cardiac amyloidosis. At the time of diagnosis, the patient's prognosis was very poor with a median survival of 5 months on the basis of the Mayo Clinic revised prognostic staging system for amyloidosis. The patient developed rapidly progressive left ventricular dysfunction and heart failure leading to cardiac arrest. The patient received a total artificial heart as a bridge to orthotopic heart and kidney transplantation and eventual stem cell transplant. He continues to be in remission and has a fair functional capacity without restriction in activities of daily living or moderate exercise. Amyloid CM is a rare and devastating disease. The natural course of the disease has made heart transplant in these patients controversial. Modern advancements in chemotherapies and advanced heart failure treatments have improved outcomes for select patients with AL amyloid CM undergoing heart transplantation. There is ongoing research seeking improvement in treatment options and outcomes for patients with this deadly disease. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
Virtual instrument: remote control and monitoring of an artificial heart driver
NASA Astrophysics Data System (ADS)
Nguyen, An H.; Farrar, David
1993-07-01
A development of a virtual instrument based on the top-down model approach for an artificial heart driver is presented. Driver parameters and status were being dynamically updated on the virtual system at the remote station. The virtual system allowed the remote operator to interact with the physical heart driver as if he/she were at the local station. Besides use as an effective training tool, the system permits an expert operator to monitor and also control the Thoratec heart driver from a distant location. We believe that the virtual instrument for biomedical devices in general and for the Thoratec heart driver in particular, not only improves system reliability but also opens up a real possibility in reducing medical cost. Utilizing the top-down scheme developed recently for telerobotics, realtime operation in both instrument display and remote communication were possible via a low bandwidth telephone medium.
Control system for an artificial heart
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1970-01-01
Inexpensive industrial pneumatic components are combined to produce control system to drive sac-type heart-assistance blood pump with controlled pulsatile pressure that makes pump rate of flow sensitive to venous /atrial/ pressure, while stroke is centered about set operating point and pump is synchronized with natural heart.
Extracorporeal total artificial heart as bailout surgery.
Perrodin, Stéphanie F; Muller, Olivier; Gronchi, Fabrizio; Liaudet, Lucas; Hullin, Roger; Kirsch, Matthias
2017-03-01
We report the use of a total extracorporeal heart for uncontrolled bleeding following a proximal left anterior descending artery perforation, using two centrifugal ventricular assist devices after heart explantation. The literature describing similar techniques and patient outcomes for this "bailout" technique are reviewed. © 2017 Wiley Periodicals, Inc.
Artificial organs versus regenerative medicine: is it true?
Nosé, Yukihiko; Okubo, Hisashi
2003-09-01
Individuals engaged in the fields of artificial kidney and artificial heart have often mistakenly stated that "the era of artificial organs is over; regenerative medicine is the future." Contrarily, we do not believe artificial organs and regenerative medicine are different medical technologies. As a matter of fact, artificial organs developed during the last 50 years have been used as a bridge to regeneration. The only difference between regenerative medicine and artificial organs is that artificial organs for the bridge to regeneration promote tissue regeneration in situ, instead of outside the body (for example, vascular prostheses, neuroprostheses, bladder substitutes, skin prostheses, bone prostheses, cartilage prostheses, ligament prostheses, etc.). All of these artificial organs are successful because tissue regeneration over a man-made prosthesis is established inside the patient's body (artificial organs to support regeneration). Another usage of the group of artificial organs for the bridge to regeneration is to sustain the functions of the patient's diseased organs during the regeneration process of the body's healthy tissues and/or organs. This particular group includes artificial kidney, hepatic assist, respiratory assist, and circulatory assist. Proof of regeneration of these healthy tissues and/or organs is demonstrated in the short-term recovery of end-stage organ failure patients (artificial organs for bridge to regeneration). A third group of artificial organs for the bridge to regeneration accelerates the regenerating process of the patient's healthy tissues and organs. This group includes neurostimulators, artificial blood (red cells) blood oxygenators, and plasmapheresis devices, including hemodiafiltrators. So-called "therapeutic artificial organs" fall into this category (artificial organs to accelerate regeneration). Thus, almost all of today's artificial organs are useful in the bridge to regeneration of healthy natural tissues and organs. It does not matter whether these tissues are cultivated inside or outside the patient's body. Thus, we strongly believe in the need for joint development programs between artificial organ technologies and regenerative medicine technologies. In particular, the importance of using both man-made substitute organ technologies and natural tissue-derived substitute organ technologies is stressed for improved medical care in the future.
History of the Kolff Laboratory turbine driven electrohydraulic artificial heart.
Topaz, S R; Flinders, T; Topaz, H A; Jones, D
1998-11-01
The concept of an electrically powered total artificial heart has been pursued by Dr. Kolff and his associates since the 1960s. Since the 1980s these efforts have been concentrated upon the development of the electrohydraulic total artificial heart, a turbine pump powered by a brushless DC motor. Dr. Kolff realized the benefits of pulsatile flow and device response to Starling's Law, and these concepts have formed the basis of subsequent design decisions. Design iterations have both solved existing problems and exposed new challenges. The current device design is greatly improved over early attempts due to the incorporation of technologies that have recently become available as the result of progress in the fields of materials and electronics and due to the lessons learned over many years of research under the guidance of Dr. Kolff. This article describes, from its inception, the last major research project of Dr. Kolff prior to his retirement. The discussion centers around development, problems and their solutions, and the reasoning for given solutions.
Pike, F. H.; Guthrie, C. C.; Stewart, G. N.
1908-01-01
Our results may be briefly summarized: 1. Blood, when defibrinated, soon loses its power to maintain the activity of the higher nervous centers, and its nutritive properties for all tissues quickly diminish. 2. Artificial fluids, as a substitute for blood, are not satisfactory. 3. The proper oxygenation of the blood is an indispensable adjunct in the resuscitation of an animal. 4. The heart usually continues to beat for some minutes after it ceases to affect a mercury manometer, and resuscitation of it within this period by extra-thoracic massage and artificial respiration is sometimes successful. 5. Resuscitation of the heart by direct massage is the most certain method at our command. 6. A proper blood-pressure is an indispensable condition for the continued normal activity of the heart. 7. Anæsthetics, hemorrhage and induced currents applied to the heart render resuscitation more difficult than asphyxia alone. PMID:19867138
"And the Beat Goes Ona... Building Artificial Hearts in the Classroom.
ERIC Educational Resources Information Center
Brock, David L.
2000-01-01
Among the many ideas and theories in anatomy and physiology, one particular topic provides all the potential benefits of learning about the human body: the circulatory system, specifically the heart. Describes a distinctive way to study circulation and the heart that allows students to explore the basic principles of vertebrate anatomy and…
NASA Astrophysics Data System (ADS)
Siewnicka, Alicja; Fajdek, Bartlomiej; Janiszowski, Krzysztof
2010-01-01
This paper presents a model of the human circulatory system with the possible addition of a parallel assist device, which was developed for the purpose of artificial heart monitoring. Information about an identification experiment of an extracorporeal ventricle assist device POLVAD is included. The modelling methods applied and the corresponding functional blocks in a PExSim package are presented. The results of the simulation for physiological conditions, left ventricle failure and pathological conditions with parallel assistance are included.
Behrens, Lindsey G.; Goodale, Nicole L.; Turek, Joseph W.; Bates, Michael J.
2015-01-01
The temporary total artificial heart (TAH-t) is approved for destination therapy or bridge to transplant and is associated with improved survival rates before and after transplantation [1]. Postoperatively, patients with the TAH-t may experience acute respiratory failure requiring significant respiratory support. Pulmonary arteriovenous extracorporeal membrane oxygenation (ECMO) has the capabilities to provide this support while minimizing the risks of barotrauma or oxygen toxicity [2]. This report presents a novel cannulation technique for ECMO to provide support for patients after the placement of the TAH-t. PMID:25910839
Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.
Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich
2017-02-01
At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Grosek, Stefan; Mlakar, Gorazd; Vidmar, Ivan; Ihan, Alojz; Primozic, Janez
2009-01-01
To evaluate the effect of interhospital air and ground transportation of artificially ventilated neonates on heart rate and peripheral blood leukocyte counts. Prospective, observational study. Level III multidisciplinary Neonatal and Pediatric Intensive Care Unit. Fifty-eight near-term artificially ventilated transported neonates between May 2006 and April 2007. Day-helicopter, day- and night-ground transportation. Heart rate at retrieval, on admission to the ICU and 1 h later, and peripheral blood leukocyte counts on admission and 1 d later were compared. Fifteen neonates were transported by helicopter during the daytime (D-HEL), 20 by daytime ground and 23 by nighttime ground transportation (D-GROUND, N-GROUND). No differences in delivery mode, birth weight, gestational age, gender, primary diagnoses for transportation, response time and duration of transportation were found between the groups. Similarly, no differences in pH, pCO(2), blood pressure and skin temperature at retrieval and on admission to the ICU were found between the three groups. The mean heart rate at retrieval did not differ significantly, while on arrival in the ICU and 1 h later the D-GROUND group of patients showed a significantly higher mean heart rate compared to the D-HEL and N-GROUND groups. Moreover, leukocyte counts on arrival in the ICU showed significantly higher leukocyte counts in the D-GROUND group of patients compared to the D-HEL group of patients. These results demonstrate that there is an association between daytime ground transportation and higher heart rate and peripheral blood leukocytes.
Lip, Gregory Y H; Collet, Jean Philippe; de Caterina, Raffaele; Fauchier, Laurent; Lane, Deirdre A; Larsen, Torben B; Marin, Francisco; Morais, Joao; Narasimhan, Calambur; Olshansky, Brian; Pierard, Luc; Potpara, Tatjana; Sarrafzadegan, Nizal; Sliwa, Karen; Varela, Gonzalo; Vilahur, Gemma; Weiss, Thomas; Boriani, Giuseppe; Rocca, Bianca
2017-12-01
Management strategies for patients with atrial fibrillation (AF) in association with valvular heart disease (VHD) have been less informed by randomized trials, which have largely focused on ‘non-valvular AF’ patients. Thromboembolic risk also varies according to valve lesion and may also be associated with CHA2DS2-VASc score risk factor components, rather than only the valve disease being causal. Given the need to provide expert recommendations for professionals participating in the care of patients presenting with AF and associated VHD, a task force was convened by the European Heart Rhythm Association (EHRA) and European Society of Cardiology (ESC) Working Group (WG) on Thrombosis, with representation from the ESC WG on Valvular Heart Disease, Heart Rhythm Society (HRS), Asia Pacific Heart Rhythm Society (APHRS), South African Heart (SA Heart) Association and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE) with the remit to comprehensively review the published evidence, and to produce a consensus document on the management of patients with AF and associated VHD, with up-to-date consensus statements for clinical practice for different forms of VHD, based on the principles of evidence-based medicine. This is an executive summary of a consensus document which proposes that the term ‘valvular AF’ is outdated and given that any definition ultimately relates to the evaluated practical use of oral anticoagulation (OAC) type, we propose a functional EHRA (Evaluated Heartvalves, Rheumatic or Artificial) categorization in relation to the type of OAC use in patients with AF, as follows: (1) EHRA (Evaluated Heartvalves, Rheumatic or Artificial) type 1 VHD, which refers to AF patients with ‘VHD needing therapy with a vitamin K antagonist (VKA)’ and (2) EHRA (Evaluated Heartvalves, Rheumatic or Artificial) type 2 VHD, which refers to AF patients with ‘VHD needing therapy with a VKA or a non-VKA oral anticoagulant also taking into consideration CHA2DS2-VASc score risk factor components.
What about My Child and Rheumatic Fever?
... damaged heart valves. This infection is called “infective endocarditis.”You can help reduce the risk for this ... clean and cavities filled can help prevent infective endocarditis. • a history of endocarditis. • an artificial heart valve. • ...
Tejera, Eduardo; Jose Areias, Maria; Rodrigues, Ana; Ramõa, Ana; Manuel Nieto-Villar, Jose; Rebelo, Irene
2011-09-01
A model construction for classification of women with normal, hypertensive and preeclamptic pregnancy in different gestational ages using maternal heart rate variability (HRV) indexes. In the present work, we applied the artificial neural network for the classification problem, using the signal composed by the time intervals between consecutive RR peaks (RR) (n = 568) obtained from ECG records. Beside the HRV indexes, we also considered other factors like maternal history and blood pressure measurements. The obtained result reveals sensitivity for preeclampsia around 80% that increases for hypertensive and normal pregnancy groups. On the other hand, specificity is around 85-90%. These results indicate that the combination of HRV indexes with artificial neural networks (ANN) could be helpful for pregnancy study and characterization.
Effects of graded load of artificial gravity on cardiovascular functions in humans.
Iwase, Satoshi; Fu, Qi; Narita, Kenichi; Morimoto, Eiichi; Takada, Hiroki; Mano, Tadaaki
2002-12-01
An artificial gravity and ergometric exercise loading device for human use was manufactured. It has the capacity of a max 2 G-load at the heart level, and a max 150 W of work-load. Eight subjects (six completed) were subjected to four repeated trials with or without 20 W ergometric exercise. Anti-G score, defined as the G-load x running time to the endpoint, was significantly higher in the exercise trials than standing trials. Heart rate (HR), mean arterial pressure (MAP), thoracic fluid index (TFI) were significantly superior during the exercise trials. Artificial gravity by centrifuge at 1.2 or 1.4 G with 40 or 60 W of ergometric workload may be an excellent countermeasure against cardiovascular deconditioning after long exposure to microgravity.
Renal Function Recovery with Total Artificial Heart Support.
Quader, Mohammed A; Goodreau, Adam M; Shah, Keyur B; Katlaps, Gundars; Cooke, Richard; Smallfield, Melissa C; Tchoukina, Inna F; Wolfe, Luke G; Kasirajan, Vigneshwar
2016-01-01
Heart failure patients requiring total artificial heart (TAH) support often have concomitant renal insufficiency (RI). We sought to quantify renal function recovery in patients supported with TAH at our institution. Renal function data at 30, 90, and 180 days after TAH implantation were analyzed for patients with RI, defined as hemodialysis supported or an estimated glomerular filtration rate (eGFR) less than 60 ml/min/1.73 m. Between January 2008 and December 2013, 20 of the 46 (43.5%) TAH recipients (age 51 ± 9 years, 85% men) had RI, mean preoperative eGFR of 48 ± 7 ml/min/1.73 m. Renal function recovery was noted at each follow-up interval: increment in eGFR (ml/min/1.73 m) at 30, 90, and 180 days was 21 ± 35 (p = 0.1), 16.5 ± 18 (p = 0.05), and 10 ± 9 (p = 0.1), respectively. Six patients (30%) required preoperative dialysis. Of these, four recovered renal function, one remained on dialysis, and one died. Six patients (30%) required new-onset dialysis. Of these, three recovered renal function and three died. Overall, 75% (15 of 20) of patients' renal function improved with TAH support. Total artificial heart support improved renal function in 75% of patients with pre-existing significant RI, including those who required preoperative dialysis.
Wells, Dennis; Villa, Chet R; Simón Morales, David Luís
2017-01-01
While use of the total artificial heart (TAH) is growing, the use of the device is not uniform across the gender and age spectrum because the vast majority of implants are in adult males. SynCardia has recently developed a smaller 50 cc TAH that was designed to accommodate patients with a body surface area as low as 1.2 m 2 (potentially even lower using virtual implantation). Herein, we describe the early use of the 50 cc TAH (10 implants in the US and 18 outside the US). Twenty-eight devices have been implanted worldwide. Nineteen (68%) patients were female, 4 (14%) were 21 years of age or younger, and 2 (7%) had a diagnosis of congenital heart disease (1 Fontan). The smallest patient, by body surface area, was 1.35 m 2 . Six patients (21%) have been placed on the Freedom Driver, all of whom have survived. Fourteen patients (50%) have had a positive outcome to date. The development of the 50 cc TAH has expanded the population of patients who may benefit from TAH support and thus may help improve outcomes for patients who have had limited biventricular support options to date. Copyright © 2017 Elsevier Inc. All rights reserved.
Sengur, Abdulkadir
2008-03-01
In the last two decades, the use of artificial intelligence methods in medical analysis is increasing. This is mainly because the effectiveness of classification and detection systems have improved a great deal to help the medical experts in diagnosing. In this work, we investigate the use of principal component analysis (PCA), artificial immune system (AIS) and fuzzy k-NN to determine the normal and abnormal heart valves from the Doppler heart sounds. The proposed heart valve disorder detection system is composed of three stages. The first stage is the pre-processing stage. Filtering, normalization and white de-noising are the processes that were used in this stage. The feature extraction is the second stage. During feature extraction stage, wavelet packet decomposition was used. As a next step, wavelet entropy was considered as features. For reducing the complexity of the system, PCA was used for feature reduction. In the classification stage, AIS and fuzzy k-NN were used. To evaluate the performance of the proposed methodology, a comparative study is realized by using a data set containing 215 samples. The validation of the proposed method is measured by using the sensitivity and specificity parameters; 95.9% sensitivity and 96% specificity rate was obtained.
An intelligent remote monitoring system for artificial heart.
Choi, Jaesoon; Park, Jun W; Chung, Jinhan; Min, Byoung G
2005-12-01
A web-based database system for intelligent remote monitoring of an artificial heart has been developed. It is important for patients with an artificial heart implant to be discharged from the hospital after an appropriate stabilization period for better recovery and quality of life. Reliable continuous remote monitoring systems for these patients with life support devices are gaining practical meaning. The authors have developed a remote monitoring system for this purpose that consists of a portable/desktop monitoring terminal, a database for continuous recording of patient and device status, a web-based data access system with which clinicians can access real-time patient and device status data and past history data, and an intelligent diagnosis algorithm module that noninvasively estimates blood pump output and makes automatic classification of the device status. The system has been tested with data generation emulators installed on remote sites for simulation study, and in two cases of animal experiments conducted at remote facilities. The system showed acceptable functionality and reliability. The intelligence algorithm also showed acceptable practicality in an application to animal experiment data.
Shiraishi, Y; Yambe, T; Yoshizawa, M; Hashimoto, H; Yamada, A; Miura, H; Hashem, M; Kitano, T; Shiga, T; Homma, D
2012-01-01
Annuloplasty for functional mitral or tricuspid regurgitation has been made for surgical restoration of valvular diseases. However, these major techniques may sometimes be ineffective because of chamber dilation and valve tethering. We have been developing a sophisticated intelligent artificial papillary muscle (PM) by using an anisotropic shape memory alloy fiber for an alternative surgical reconstruction of the continuity of the mitral structural apparatus and the left ventricular myocardium. This study exhibited the mitral regurgitation with regard to the reduction in the PM tension quantitatively with an originally developed ventricular simulator using isolated goat hearts for the sophisticated artificial PM. Aortic and mitral valves with left ventricular free wall portions of isolated goat hearts (n=9) were secured on the elastic plastic membrane and statically pressurized, which led to valvular leaflet-papillary muscle positional change and central mitral regurgitation. PMs were connected to the load cell, and the relationship between the tension of regurgitation and PM tension were measured. Then we connected the left ventricular specimen model to our hydraulic ventricular simulator and achieved hemodynamic simulation with the controlled tension of PMs.
[Artificial heart--turbo type blood pump for long-term use].
Akamatsu, Teruaki
2003-05-01
Shortage of donor heart for transplantation necessitates long-term artificial assist heart. Turbo-pump is smaller, simpler and cheaper than the pulsatile displacement type pump, but the turbo-pump has defect of thrombus formation at the shaft seal. Our centrifugal pump with magnetically suspended impellers overcomes this defect and is ready for clinical trials now. The structures and functions are described and are compared with the other newly-developed pump of the same kinds with us. And also the pumps of centrifugal type and axial-type, of which impellers are supported by pivots, are reviewed briefly from the stand point for long-term use. Other pumps are referred too: pumps with hydrodynamic bearing and a pump with the shaft seal which is washed and cooled by saline solution.
Kalya, Anantharam; Jaroszewski, Dawn; Pajaro, Octavio; Scott, Robert; Gopalan, Radha; Kasper, Diane; Arabia, Francisco
2013-01-01
Cardiac allograft rejection and failure may require mechanical circulatory support as bridge-to-retransplantation. Prognosis in this patient group is poor and implantable ventricular assist devices have had limited success due to organ failure associated with the high dose immunosuppression required to treat ongoing rejection. We present a case from our institution and the world-wide experience utilizing the SynCardia CardioWest Total Artificial Heart (TAH-t; SynCardia Systems, Inc., Tucson, AZ, USA) for replacement of the failing graft, recovery of patient and end-organ failure with ultimate bridge to retransplantation. We present our experience and review of world-wide experience for use of TAH-t in this type patient. © 2013 John Wiley & Sons A/S.
Artificial heart for humanoid robot using coiled SMA actuators
NASA Astrophysics Data System (ADS)
Potnuru, Akshay; Tadesse, Yonas
2015-03-01
Previously, we have presented the design and characterization of artificial heart using cylindrical shape memory alloy (SMA) actuators for humanoids [1]. The robotic heart was primarily designed to pump a blood-like fluid to parts of the robot such as the face to simulate blushing or anger by the use of elastomeric substrates for the transport of fluids. It can also be used for other applications. In this paper, we present an improved design by using high strain coiled SMAs and a novel pumping mechanism that uses sequential actuation to create peristalsis-like motions, and hence pump the fluid. Various placements of actuators will be investigated with respect to the silicone elastomeric body. This new approach provides a better performance in terms of the fluid volume pumped.
Design and Evaluation of a Fully Implantable Control Unit for Blood Pumps
Unthan, Kristin; Gräf, Felix; Laumen, Marco; Finocchiaro, Thomas; Sommer, Christoph; Lanmüller, Hermann; Steinseifer, Ulrich
2015-01-01
As the number of donor hearts is limited while more and more patients suffer from end stage biventricular heart failure, Total Artificial Hearts become a promising alternative to conventional treatment. While pneumatic devices sufficiently supply the patients with blood flow, the patient's quality of life is limited by the percutaneous pressure lines and the size of the external control unit. This paper describes the development of the control unit of the ReinHeart, a fully implantable Total Artificial Heart. General requirements for any implantable control unit are defined from a technical and medical point of view: necessity of a Transcutaneous Energy Transmission, autonomous operation, safety, geometry, and efficiency. Based on the requirements, a prototype is designed; it incorporates a LiFePo4 battery pack with charger, a rectifier for transcutaneous energy transmission, the motor's driver electronics, and a microcontroller which monitors and controls all functions. In validation tests, the control unit demonstrated a stable operation on TET and battery supply and a safe switching from one supply to the other. The overall mean efficiency is 14% on TET and 22% on battery supply. The control unit is suitable for chronic animal trials of the ReinHeart. PMID:26583095
Total Artificial Heart as Bridge to Heart Transplantation in Chagas Cardiomyopathy: Case Report.
Ruzza, A; Czer, L S C; De Robertis, M; Luthringer, D; Moriguchi, J; Kobashigawa, J; Trento, A; Arabia, F
2016-01-01
Chagas disease (CD) is becoming an increasingly recognized cause of dilated cardiomyopathy outside of Latin America, where it is endemic, due to population shifts and migration. Heart transplantation (HTx) is a therapeutic option for end-stage cardiomyopathy due to CD, but may be considered a relative contraindication due to potential reactivation of the causative organism with immunosuppression therapy. The total artificial heart (TAH) can provide mechanical circulatory support in decompensated patients with severe biventricular dysfunction until the time of HTx, while avoiding immunosuppressive therapy and removing the organ most affected by the causative organism. We report herein a patient with CD and severe biventricular dysfunction, who had mechanical circulatory support with a TAH for more than 6 months, followed by successful orthotopic HTx and treatment with benznidazole for 3 months. The patient had no evidence of recurrent disease in the transplanted heart based on endomyocardial biopsy up to 1 year post-transplantation, and remains alive more than 30 months after insertion of a TAH and 24 months after HTx. Copyright © 2016 Elsevier Inc. All rights reserved.
Moshkivska, L V; Nastenko, E A; Golovenko, O S; Lazoryshynets, V V
2015-11-01
The risk factors of pulmonary complications occurrence were analyzed in children, operated on for inborn heart failures in atrificial blood circulation environment. Pulmonary complications rate and the risk factors of their occurrence were analyzed.
Heart Pump Design for Cleveland Clinic Foundation
NASA Technical Reports Server (NTRS)
2005-01-01
Through a Lewis CommTech Program project with the Cleveland Clinic Foundation, the NASA Lewis Research Center is playing a key role in the design and development of a permanently implantable, artificial heart pump assist device. Known as the Innovative Ventricular Assist System (IVAS), this device will take on the pumping role of the damaged left ventricle of the heart. The key part of the IVAS is a nonpulsatile (continuous flow) artificial heart pump with centrifugal impeller blades, driven by an electric motor. Lewis is part of an industry and academia team, led by the Ohio Aerospace Institute (OAI), that is working with the Cleveland Clinic Foundation to make IVAS a reality. This device has the potential to save tens of thousands of lives each year, since 80 percent of heart attack victims suffer irreversible damage to the left ventricle, the part of the heart that does most of the pumping. Impeller blade design codes and flow-modeling analytical codes will be used in the project. These codes were developed at Lewis for the aerospace industry but will be applicable to the IVAS design project. The analytical codes, which currently simulate the flow through the compressor and pump systems, will be used to simulate the flow within the blood pump in the artificial heart assist device. The Interdisciplinary Technology Office heads up Lewis' efforts in the IVAS project. With the aid of numerical modeling, the blood pump will address many design issues, including some fluid-dynamic design considerations that are unique to the properties of blood. Some of the issues that will be addressed in the design process include hemolysis, deposition, recirculation, pump efficiency, rotor thrust balance, and bearing lubrication. Optimum pumping system performance will be achieved by modeling all the interactions between the pump components. The interactions can be multidisciplinary and, therefore, are influenced not only by the fluid dynamics of adjacent components but also by thermal and structural effects. Lewis-developed flow-modeling codes to be used in the pump simulations will include a one-dimensional code and an incompressible three-dimensional Navier-Stokes flow code. These codes will analyze the prototype pump designed by the Cleveland Clinic Foundation. With an improved understanding of the flow phenomena within the prototype pump, design changes to improve the performance of the pump system can be verified by computer prior to fabrication in order to reduce risks. The use of Lewis flow modeling codes during the design and development process will improve pump system performance and reduce the number of prototypes built in the development phase. The first phase of the IVAS project is to fully develop the prototype in a laboratory environment that uses a water/glycerin mixture as the surrogate fluid to simulate blood. A later phase of the project will include testing in animals for final validation. Lewis will be involved in the IVAS project for 3 to 5 years.
Marom, Gil; Chiu, Wei-Che; Crosby, Jessica R.; DeCook, Katrina J.; Prabhakar, Saurabh; Horner, Marc; Slepian, Marvin J.; Bluestein, Danny
2014-01-01
The SynCardia total artificial heart (TAH) is the only FDA approved device for replacing hearts in patients with congestive heart failure. It pumps blood via pneumatically driven diaphragms and controls the flow with mechanical valves. While it has been successfully implanted in more than 1,300 patients, its size precludes implantation in smaller patients. This study’s aim was to evaluate the viability of scaled-down TAHs by quantifying thrombogenic potentials from flow patterns. Simulations of systole were first conducted with stationary valves, followed by an advanced full-cardiac-cycle model with moving valves. All the models included deforming diaphragms and platelet suspension in the blood flow. Flow stress-accumulations were computed for the platelet trajectories and thrombogenic potentials were assessed. The simulations successfully captured complex flow patterns during various phases of the cardiac-cycle. Increased stress-accumulations, but within the safety margin of acceptable thrombogenicity, were found in smaller TAHs, indicating that they are clinically viable. PMID:25354999
Leopaldi, Alberto M; Wrobel, Krzysztof; Speziali, Giovanni; van Tuijl, Sjoerd; Drasutiene, Agne; Chitwood, W Randolph
2018-01-01
Previously, cardiac surgeons and cardiologists learned to operate new clinical devices for the first time in the operating room or catheterization laboratory. We describe a biosimulator that recapitulates normal heart valve physiology with associated real-time hemodynamic performance. To highlight the advantages of this simulation platform, transventricular extruded polytetrafluoroethylene artificial chordae were attached to repair flail or prolapsing mitral valve leaflets. Guidance for key repair steps was by 2-dimensional/3-dimensional echocardiography and simultaneous intracardiac videoscopy. Multiple surgeons have assessed the use of this biosimulator during artificial chordae implantations. This simulation platform recapitulates normal and pathologic mitral valve function with associated hemodynamic changes. Clinical situations were replicated in the simulator and echocardiography was used for navigation, followed by videoscopic confirmation. This beating heart biosimulator reproduces prolapsing mitral leaflet pathology. It may be the ideal platform for surgeon and cardiologist training on many transcatheter and beating heart procedures. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.
Peberdy, Mary Ann; Gluck, Jason A; Ornato, Joseph P; Bermudez, Christian A; Griffin, Russell E; Kasirajan, Vigneshwar; Kerber, Richard E; Lewis, Eldrin F; Link, Mark S; Miller, Corinne; Teuteberg, Jeffrey J; Thiagarajan, Ravi; Weiss, Robert M; O'Neil, Brian
2017-06-13
Cardiac arrest in patients on mechanical support is a new phenomenon brought about by the increased use of this therapy in patients with end-stage heart failure. This American Heart Association scientific statement highlights the recognition and treatment of cardiovascular collapse or cardiopulmonary arrest in an adult or pediatric patient who has a ventricular assist device or total artificial heart. Specific, expert consensus recommendations are provided for the role of external chest compressions in such patients. © 2017 American Heart Association, Inc.
The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.
Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard
2017-10-01
Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Current progress in the development of a totally implantable Gyro centrifugal artificial heart.
Takami, Y; Ohtsuka, G; Mueller, J; Ebner, M; Tayama, E; Ohashi, Y; Taylor, D; Fernandes, J; Schima, H; Schmallegger, H; Wolner, E; Nosé, Y
1998-01-01
A totally implantable centrifugal artificial heart has been developed using a miniaturized pivot bearing supported centrifugal pump (Gyro PI pump). The authors report current progress in its development. The Gyro PI-601 has a priming volume of 20 ml, weighs 100 g, has a height of 60 mm, and has a diameter of 65 mm. This pump can provide 8 L/min against 150 mmHg at 2,250 rpm. It is driven by an miniaturized DC brushless motor with the coils fixed in a plastic mold that is waterproof and made of titanium (weight, 204 g; height, 18 mm; diameter, 65 mm). In this centrifugal artificial heart, two Gyro PI pumps are implanted independently to replace cardiac function without resecting the native heart. Its anatomic and surgical feasibility were confirmed experimentally. The Gyro PI-601 was implanted as a right or left ventricular assist device in the preperitoneal space of five calves. All five tests proceeded without any thromboembolic symptoms. One of five tests was extended more than 1 month to confirm the long-term feasibility of the Gyro PI-601 pump system. Based on the satisfactory results of the in vivo tests, the material conversion of the Gyro PI from polycarbonate to titanium alloy (Ti-6A1-4V) was undertaken to improve its biocompatibility for long-term implantation.
NASA Astrophysics Data System (ADS)
Chiryatyeva, Aleksandra; Trebushat, Dmitry; Prokhorokhin, Aleksei; Khakhalkin, Vladimir; Andreev, Mark; Novokhreschenov, Aleksei; Kretov, Evgeny
2017-12-01
Cardiovascular diseases are the leading cause of death worldwide. Valvular heart disease often requires valve repair or replacement. Today, surgery uses xenograft—porcine or bovine pericardium. However, bioprosthetic valves do not ensure sufficient durability. We investigated 0.6% glutaraldehyde-treated porcine pericardium to define its properties. Using a tensile test stand, we studied characteristics of the polymeric material—expanded polytetrafluoroethylene (ePTFE)—and compared it to xenopericardium. The artificial material provides a better durability; it has higher elastic modulus and ultimate tensile strength. However, ePTFE samples demonstrated direction anisotropy due to extrusion features. It requires the enhancement of quality of the ePTFE sheet or investigation of other polymeric materials to find the adequate replacement for bioprosthetic heart valves.
Tarzia, Vincenzo; Braccioni, Fausto; Bortolussi, Giacomo; Buratto, Edward; Gallo, Michele; Bottio, Tomaso; Vianello, Andrea; Gerosa, Gino
2016-06-01
Management of patients treated with CardioWest Total Artificial Heart (CW-TAH) as a bridge to heart transplantation (HTx) is complicated by difficulties in determining the optimal timing of transplantation. We present a case of a 53-year-old man supported as an outpatient with a CW-TAH, whose condition deteriorated following exchange of the portable driver. The patient was followed-up with serial cardiopulmonary exercise testing (CPET) which demonstrated a fall of peak VO2 to below 12 ml/kg/min following driver substitution, and the patient was subsequently treated with urgent orthotopic HTx. This case highlights the potential utility of CPET as a means for monitoring and indicating timing of HTx in patients with CW-TAH, as well as the potential for clinical deterioration following portable driver substitution.
Vacuum generation in pneumatic artificial heart drives with a specially designed ejector system.
Schima, H; Huber, L; Spitaler, F
1990-06-01
To improve the filling characteristics of pneumatically driven membrane artificial hearts (AHs), a vacuum is applied during diastole. This paper describes an ejector system for AH-drivers based on the Venturi effect, which was designed for this purpose. It provides vacuums of more than -40 mmHg at flow rates up to 50 l/min requiring a supplying primary gas pressure of less than 150 kPa (1140 mmHg). Under normal working conditions, the necessary supply flow was less than 5l/min. The device is small, cheap, quiet and fail-safe, and has been evaluated successfully in experimental and clinical use.
Design and analysis of a field modulated magnetic screw for artificial heart
NASA Astrophysics Data System (ADS)
Ling, Zhijian; Ji, Jinghua; Wang, Fangqun; Bian, Fangfang
2017-05-01
This paper proposes a new electromechanical energy conversion system, called Field Modulated Magnetic Screw (FMMS) as a high force density linear actuator for artificial heart. This device is based on the concept of magnetic screw and linear magnetic gear. The proposed FMMS consists of three parts with the outer and inner carrying the radially magnetized helically permanent-magnet (PM), and the intermediate having a set of helically ferromagnetic pole pieces, which modulate the magnetic fields produced by the PMs. The configuration of the newly designed FMMS is presented and its electromagnetic performances are analyzed by using the finite-element analysis, verifying the advantages of the proposed structure.
Potential woodpecker nest trees through artificial inoculation of heart rots
Richard N. Conner; James G. Dickson; J. Howard Williamson
1983-01-01
We suggest that the fungus Spongipellis pachyodon might be used to artificially create suitable hardwood nest trees for woodpeckers in both young and older trees and when supplies of potential nest trees are limited. Sizes of trees suitable for inoculation, inoculation heights, and densities of snags are suggested for six species of woodpeckers.
Mathematical Model Analysis of Heart-Arterial Interaction in Hypertension
2001-10-25
conscious dogs with dilated cardiomyopathy ,” ! " # , vol. 260, pp. H1903-H1911, 1991. [7] P. Segers, N...with data measured in the isolated canine [14] or cat [15] heart, pumping into an artificial load or in the intact sheep [16] and human [7]. Left...instantaneous pressure-volume ratio of the canine left ventricle and effects of epinephrine and heart rate on the ratio,” , vol. 32, pp. 314
AbioCor totally implantable artificial heart. How will it impact hospitals?
2002-09-01
Although heart transplantation remains the most effective treatment for severe heart failure, there are far fewer donor hearts available than there are patients who could benefit from them. One approach to addressing this shortfall is the total artificial heart, or TAH. To date, however, no TAH design has been able to achieve one of the ultimate goals of heart replacement: to allow a patient to live a reasonably normal life without being connected to external machinery. A new design, the AbioCor TAH developed by Abiomed Inc., may make this goal achievable. Thanks to a power system that transfers energy through the skin without the aid of wires, the AbioCor--currently undergoing clinical trials in the United States--allows the patient to be completely mobile. The lack of transcutaneous wires also eliminates the primary source of the infections that have plagued TAH patients in the past. Though it is not without drawbacks, the AbioCor could represent a crucial advance in TAH technology. In this Technology Overview, we describe the operation of the AbioCor and discuss its likely impact on hospitals if it is approved for marketing in the United States. We also discuss a related cardiac-support technology: ventricular assist devices (VADs), which may also be used for permanent cardiac support someday.
Marom, Gil; Chiu, Wei-Che; Slepian, Marvin J; Bluestein, Danny
2014-01-01
The total artificial heart (TAH) is a bi-ventricular mechanical circulatory support device that replaces the heart in patients with end-stage congestive heart failure. The device acts as blood pump via pneumatic activation of diaphragms altering the volume of the ventricular chambers. Flow in and out of the ventricles is controlled by mechanical heart valves. The aim of this study is to evaluate the flow regime in the TAH and to estimate the thrombogenic potential during systole. Toward that goal, three numerical models of TAHs of differing sizes, that include the deforming diaphragm and the blood flow from the left chamber to the aorta, are introduced. A multiphase model with injection of platelet particles is employed to calculate their trajectories. The shear stress accumulation in the three models are calculated along the platelets trajectories and their probability density functions, which represent the `thrombogenic footprint' of the device are compared. The calculated flow regime successfully captures the mitral regurgitation and the flows that open and close the aortic valve during systole. Physiological velocity magnitudes are found in all three models, with higher velocities and increased stress accumulation predicted for smaller devices.
Observation of cavitation in a mechanical heart valve in a total artificial heart.
Lee, Hwansung; Tsukiya, Tomonori; Homma, Akihiko; Kamimura, Tadayuki; Takewa, Yoshiaki; Nishinaka, Tomohiro; Tatsumi, Eisuke; Taenaka, Yoshiyuki; Takano, Hisateru; Kitamura, Soichiro
2004-01-01
Recently, cavitation on the surface of mechanical heart valves has been studied as a cause of fractures occurring in implanted mechanical heart valves. The cause of cavitation in mechanical heart valves was investigated using the 25 mm Medtronic Hall valve and the 23 mm Omnicarbon valve. Closing of these valves in the mitral position was simulated in an electrohydraulic totally artificial heart. Tests were conducted under physiologic pressures at heart rates from 60 to 100 beats per minute with cardiac outputs from 4.8 to 7.7 L/min. The disk closing motion was measured by a laser displacement sensor. A high-speed video camera was used to observe the cavitation bubbles in the mechanical heart valves. The maximum closing velocity of the Omnicarbon valve was faster than that of the Medtronic Hall valve. In both valves, the closing velocity of the leaflet, used as the cavitation threshold, was approximately 1.3-1.5 m/s. In the case of the Medtronic Hall valve, cavitation bubbles were generated by the squeeze flow and by the effects of the venturi and the water hammer. With the Omnicarbon valve, the cavitation bubbles were generated by the squeeze flow and the water hammer. The mechanism leading to the development of cavitation bubbles depended on the valve closing velocity and the valve stop geometry. Most of the cavitation bubbles were observed around the valve stop and were generated by the squeeze flow.
Carrault, G; Cordier, M-O; Quiniou, R; Wang, F
2003-07-01
This paper proposes a novel approach to cardiac arrhythmia recognition from electrocardiograms (ECGs). ECGs record the electrical activity of the heart and are used to diagnose many heart disorders. The numerical ECG is first temporally abstracted into series of time-stamped events. Temporal abstraction makes use of artificial neural networks to extract interesting waves and their features from the input signals. A temporal reasoner called a chronicle recogniser processes such series in order to discover temporal patterns called chronicles which can be related to cardiac arrhythmias. Generally, it is difficult to elicit an accurate set of chronicles from a doctor. Thus, we propose to learn automatically from symbolic ECG examples the chronicles discriminating the arrhythmias belonging to some specific subset. Since temporal relationships are of major importance, inductive logic programming (ILP) is the tool of choice as it enables first-order relational learning. The approach has been evaluated on real ECGs taken from the MIT-BIH database. The performance of the different modules as well as the efficiency of the whole system is presented. The results are rather good and demonstrate that integrating numerical techniques for low level perception and symbolic techniques for high level classification is very valuable.
Total Artificial Heart and Chronic Haemodialysis: A Possible Bridge to Transplantation?
Demiselle, Julien; Besson, Virginie; Sayegh, Johnny; Subra, Jean-François; Augusto, Jean-François
2016-01-01
Total artificial heart (TAH) device is sometimes necessary to treat end stage heart failure (HF). After surgery, renal impairment can occur with the need of renal replacement therapy. We report the case of a 51-year-old man who was treated with conventional hemodialysis (HD) while on support with TAH. The patient underwent HD while on TAH support during 14 months. He benefited from conventional HD, 6 sessions per week. HD sessions were well tolerated, and patient's condition and quality of life improved significantly. The main difficulty was to maintain red blood cell level because of chronic hemolysis due to TAH, which required repetitive blood transfusions, resulting in a high rate of human leukocyte antigen sensitization. Unfortunately, the patient died of mesenteric ischemia due to anticoagulation under dosing. We conclude that HD treatment is possible despite TAH and should be considered in patients with both end stage renal and HF. © 2016 S. Karger AG, Basel.
The Japanese artificial organs scene: current status.
Mitamura, Yoshinori; Murabayashi, Shun
2005-08-01
Artificial organs and regenerative medicine are the subjects of very active research and development (R&D) in Japan and various artificial organs are widely used in patients. Results of the R&D are presented at the annual conference of the Japanese Society for Artificial Organs (JSAO). Progress in the fields of artificial organs and regenerative medicine are reviewed annually in the Japanese Journal of Artificial Organs. The official English-language journal of JSAO, Journal of Artificial Organs, also publishes many original articles by Japanese researchers. Although the annual conference and the publications of JSAO provide the world with update information on artificial organs and regenerative medicine in Japan, the information is not always understood appropriately in the rest of the world, mainly due to language problems. This article therefore introduces the current status of artificial organs and regenerative medicine in Japan. Artificial hearts and metabolic support systems are reviewed here and other interesting areas such as regenerative medicine can be found elsewhere.
Hybrid Continuous-Flow Total Artificial Heart.
Fox, Carson; Chopski, Steven; Murad, Nohra; Allaire, Paul; Mentzer, Robert; Rossano, Joseph; Arabia, Francisco; Throckmorton, Amy
2018-05-01
Clinical studies using total artificial hearts (TAHs) have demonstrated that pediatric and adult patients derive quality-of-life benefits from this form of therapy. Two clinically-approved TAHs and other pumps under development, however, have design challenges and limitations, including thromboembolic events, neurologic impairment, infection risk due to large size and percutaneous drivelines, and lack of ambulation, to name a few. To address these limitations, we are developing a hybrid-design, continuous-flow, implantable or extracorporeal, magnetically-levitated TAH for pediatric and adult patients with heart failure. This TAH has only two moving parts: an axial impeller for the pulmonary circulation and a centrifugal impeller for the systemic circulation. This device will utilize the latest generation of magnetic bearing technology. Initial geometries were established using pump design equations, and computational modeling provided insight into pump performance. The designs were the basis for prototype manufacturing and hydraulic testing. The study results demonstrate that the TAH is capable of delivering target blood flow rates of 1-6.5 L/min with pressure rises of 1-92 mm Hg for the pulmonary circulation and 24-150 mm Hg for the systemic circulation at 1500-10 000 rpm. This initial design of the TAH was successful and serves as the foundation to continue its development as a novel, more compact, nonthrombogenic, and effective therapeutic alternative for infants, children, adolescents, and adults with heart failure. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
First clinical use of a bioprosthetic total artificial heart: report of two cases.
Carpentier, Alain; Latrémouille, Christian; Cholley, Bernard; Smadja, David M; Roussel, Jean-Christian; Boissier, Elodie; Trochu, Jean-Noël; Gueffet, Jean-Pierre; Treillot, Michèle; Bizouarn, Philippe; Méléard, Denis; Boughenou, Marie-Fazia; Ponzio, Olivier; Grimmé, Marc; Capel, Antoine; Jansen, Piet; Hagège, Albert; Desnos, Michel; Fabiani, Jean-Noël; Duveau, Daniel
2015-10-17
The development of artificial hearts in patients with end-stage heart disease have been confronted with the major issues of thromboembolism or haemorrhage. Since valvular bioprostheses are associated with a low incidence of these complications, we decided to use bioprosthetic materials in the construction of a novel artificial heart (C-TAH). We report here the device characteristics and its first clinical applications in two patients with end-stage dilated cardiomyopathy. The aim of the study was to evaluate safety and feasibility of the CARMAT TAH for patients at imminent risk of death from biventricular heart failure and not eligible for transplant. The C-TAH is an implantable electro-hydraulically actuated pulsatile biventricular pump. All components, batteries excepted, are embodied in a single device positioned in the pericardial sac after excision of the native ventricles. We selected patients admitted to hospital who were at imminent risk of death, having irreversible biventricular failure, and not eligible for heart transplantation, from three cardiac surgery centres in France. The C-TAH was implanted in two male patients. Patient 1, aged 76 years, had the C-TAH implantation on Dec 18, 2013; patient 2, aged 68 years, had the implantation on Aug 5, 2014. The cardiopulmonary bypass times for C-TAH implantation were 170 min for patient 1 and 157 min for patient 2. Both patients were extubated within the first 12 postoperative hours and had a rapid recovery of their respiratory and circulatory functions as well as a normal mental status. Patient 1 presented with a tamponade on day 23 requiring re-intervention. Postoperative bleeding disorders prompted anticoagulant discontinuation. The C-TAH functioned well with a cardiac output of 4·8-5·8 L/min. On day 74, the patient died due to a device failure. Autopsy did not detect any relevant thrombus formation within the bioprosthesis nor the different organs, despite a 50-day anticoagulant-free period. Patient 2 experienced a transient period of renal failure and a pericardial effusion requiring drainage, but otherwise uneventful postoperative course. He was discharged from the hospital on day 150 after surgery with a wearable system without technical assistance. After 4 months at home, the patient suffered low cardiac output. A change of C-TAH was attempted but the patient died of multiorgan failure. This preliminary experience could represent an important contribution to the development of total artificial hearts using bioprosthetic materials. CARMAT SA. Copyright © 2015 Elsevier Ltd. All rights reserved.
Maher, Dermot P; Loyferman, Rusty; Yumul, Roya; Louy, Charles
2015-01-01
The implantation of total artificial hearts (TAH) via midline sternotomy for the treatment of severe biventricular cardiac dysfunction is associated with complex postoperative pain management. Ketamaine increases blood pressure by raising sympathetic outflow and cardiac output; however, ketamine is a direct vasodilator on isolated arterial tissues. In the setting of a TAH with a mechanically fixed cardiac output, a ketamine infusion for postoperative pain control has the potential to decrease blood pressure due to direct arterial vasodilation. We present the initial experience with a ketamine infusion in a patient with a TAH with minimal observed decreases in blood pressure and significantly improved postoperative pain.
Statistical Software and Artificial Intelligence: A Watershed in Applications Programming.
ERIC Educational Resources Information Center
Pickett, John C.
1984-01-01
AUTOBJ and AUTOBOX are revolutionary software programs which contain the first application of artificial intelligence to statistical procedures used in analysis of time series data. The artificial intelligence included in the programs and program features are discussed. (JN)
Cuenca-Navalon, Elena; Laumen, Marco; Finocchiaro, Thomas; Steinseifer, Ulrich
2016-07-01
A physiological control algorithm is being developed to ensure an optimal physiological interaction between the ReinHeart total artificial heart (TAH) and the circulatory system. A key factor for that is the long-term, accurate determination of the hemodynamic state of the cardiovascular system. This study presents a method to determine estimation models for predicting hemodynamic parameters (pump chamber filling and afterload) from both left and right cardiovascular circulations. The estimation models are based on linear regression models that correlate filling and afterload values with pump intrinsic parameters derived from measured values of motor current and piston position. Predictions for filling lie in average within 5% from actual values, predictions for systemic afterload (AoPmean , AoPsys ) and mean pulmonary afterload (PAPmean ) lie in average within 9% from actual values. Predictions for systolic pulmonary afterload (PAPsys ) present an average deviation of 14%. The estimation models show satisfactory prediction and confidence intervals and are thus suitable to estimate hemodynamic parameters. This method and derived estimation models are a valuable alternative to implanted sensors and are an essential step for the development of a physiological control algorithm for a fully implantable TAH. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Computer Program Recognizes Patterns in Time-Series Data
NASA Technical Reports Server (NTRS)
Hand, Charles
2003-01-01
A computer program recognizes selected patterns in time-series data like digitized samples of seismic or electrophysiological signals. The program implements an artificial neural network (ANN) and a set of N clocks for the purpose of determining whether N or more instances of a certain waveform, W, occur within a given time interval, T. The ANN must be trained to recognize W in the incoming stream of data. The first time the ANN recognizes W, it sets clock 1 to count down from T to zero; the second time it recognizes W, it sets clock 2 to count down from T to zero, and so forth through the Nth instance. On the N + 1st instance, the cycle is repeated, starting with clock 1. If any clock has not reached zero when it is reset, then N instances of W have been detected within time T, and the program so indicates. The program can readily be encoded in a field-programmable gate array or an application-specific integrated circuit that could be used, for example, to detect electroencephalographic or electrocardiographic waveforms indicative of epileptic seizures or heart attacks, respectively.
Ryan, Thomas D; Jefferies, John L; Zafar, Farhan; Lorts, Angela; Morales, David L S
2015-01-01
Advances in medical therapies have yielded improvement in morbidity and a decrease in mortality for patients with congenital heart disease, both surgically palliated and uncorrected. An unintended consequence is a cohort of adolescent and adult patients with heart failure who require alternative therapies. One intriguing option is placement of a total artificial heart (TAH) either as a bridge to transplant or as a destination therapy. Of the 1091 Jarvik-7 type TAH (Symbion, CardioWest and SynCardia) placed between 1985 and 2012, only 24 have been performed in patients with congenital heart disease, and a total of 51 were placed in patients younger than 21. At our institution, the SynCardia TAH was implanted in a 19-year-old patient with cardiac allograft failure because of chronic rejection and related multisystem organ failure including need for hemodialysis. Over the next year, she was nutritionally and physically rehabilitated, as were her end organs, allowing her to come off dialysis, achieve normal renal function and eventually be successfully transplanted. Given the continued growth of adolescent and adult congenital heart disease populations with end-stage heart failure, the TAH may offer therapeutic options where previously there were few. In addition, smaller devices such as the SynCardia 50/50 will open the door for applications in smaller children. The Freedom Driver offers the chance for patients to leave the hospital with a TAH, as does the AbioCor, which is a fully implantable TAH option. In this report, we review the history of the TAH and potential applications in adolescent patients and congenital heart disease.
Automatic Emboli Detection System for the Artificial Heart
NASA Astrophysics Data System (ADS)
Steifer, T.; Lewandowski, M.; Karwat, P.; Gawlikowski, M.
In spite of the progress in material engineering and ventricular assist devices construction, thromboembolism remains the most crucial problem in mechanical heart supporting systems. Therefore, the ability to monitor the patient's blood for clot formation should be considered an important factor in development of heart supporting systems. The well-known methods for automatic embolus detection are based on the monitoring of the ultrasound Doppler signal. A working system utilizing ultrasound Doppler is being developed for the purpose of flow estimation and emboli detection in the clinical artificial heart ReligaHeart EXT. Thesystem will be based on the existing dual channel multi-gate Doppler device with RF digital processing. A specially developed clamp-on cannula probe, equipped with 2 - 4 MHz piezoceramic transducers, enables easy system setup. We present the issuesrelated to the development of automatic emboli detection via Doppler measurements. We consider several algorithms for the flow estimation and emboli detection. We discuss their efficiency and confront them with the requirements of our experimental setup. Theoretical considerations are then met with preliminary experimental findings from a) flow studies with blood mimicking fluid and b) in-vitro flow studies with animal blood. Finally, we discuss some more methodological issues - we consider several possible approaches to the problem of verification of the accuracy of the detection system.
Simulation of heart infarction by laser microbeams and induction of arrhythmias by optical tweezers
NASA Astrophysics Data System (ADS)
Perner, Birgit; Monajembashi, Shamci; Rapp, Alexander; Wollweber, Leo; Greulich, Karl Otto
2004-10-01
Laser microbeam and optical tweezers were used for micromanipulation of a heart tissue model consisting of embryonic chicken cardiomyocytes and bibroblasts. Using the laser microbeam a would was created, i.e. a sort of artificial heart infarction was generated. The first steps of wound repair were observed by live cell imaging. A complete filling of teh would primarily by migrating fibroblasts but not by cardiomyocytes was detected 18 hours after wounding. In another set of experiments erythrocyte mediated force application (EMFA) by optical tweezers was applied for optomechanical manipulatoin of cardiomyocytes and fibroblasts. Here we demonstrate induction of dramatic distrubances of calcium waves in a group of synchronously beating cardiomyocytes by an optomechanical input that results in cellular deformation. Surprisingly, it was found that putatively non-excitable fibroblasts respond to this mechanical stress with calcium oscillations. The results reported here indicate that the induction of artificial heart infarction can provide insights into healing processes after mycardial injury. EMFA is capable to examine effects of myocardial overload and to provide important information about processes triggered by mechanical stress on the level of single or very few cells. As a perspective, the preseneted techniques may be used to study the influence of drugs on wound healing and coordination of beating in the heart.
NASA Astrophysics Data System (ADS)
Grad, Leszek; Murawski, Krzysztof; Sulej, Wojciech
2017-08-01
In the article we presented results obtained during research, which are the continuation of work on the use of artificial neural networks to determine the relationship between the view of the membrane and the stroke volume of the blood chamber of the mechanical prosthetic heart. The purpose of the research was to increase the accuracy of determining the blood chamber volume. Therefore, the study was focused on the technique of the features that the image extraction gives. During research we used the wavelet transform. The achieved results were compared to the results obtained by other previous methods. Tests were conducted on the same mechanical prosthetic heart model used in previous experiments.
Future Prospects for the Total Artificial Heart.
Sunagawa, Gengo; Horvath, David J; Karimov, Jamshid H; Moazami, Nader; Fukamachi, Kiyotaka
2016-01-01
A total artificial heart (TAH) is the sole remaining option for patients with biventricular failure who cannot be rescued by left ventricular assist devices (LVADs) alone. However, the pulsatile TAH in clinical use today has limitations: large pump size, unknown durability, required complex anticoagulation regimen, and association with significant postsurgical complications. That pump is noisy; its large pneumatic driving lines traverse the body, with bulky external components for its drivers. Continuous-flow pumps, which caused a paradigm shift in the LVAD field, have already contributed to the rapidly evolving development of TAHs. Novel continuous-flow TAHs are only in preclinical testing or developmental stages. We here review the current state of TAHs, with recommended requirements for the TAH of the future.
Proposal of a new electromechanical total artificial heart: the TAH Serpentina.
Sauer, I M; Frank, J; Bücherl, E S
1999-03-01
A new type of energy converter for an electro-mechanical total artificial heart (TAH) based on the principle of a unidirectional moving motor is described. Named the TAH Serpentina, the concept consists of 2 major parts, a pendulum shaped movable element fixed on one side using a joint bearing and a special shaped drum cam. Pusher plates are mounted flexibly to the crossbar of the pendulum. A motor drives the special shaped drum cam linked to the pendulum through a ball bearing. The circular motion of the unidirectional moving brushless DC motor is transferred into the linear motion of the pendulum to drive the pusher plates. Using a crossbar with a variable length, the stroke of the pendulum and therefore the displaced blood volume is alterable. To achieve a variable length, an electric driven screw thread or a hydraulic system is possible. Comparable to the natural heart, cardiac output would be determined by frequency and stroke volume.
Computation of incompressible viscous flows through artificial heart devices with moving boundaries
NASA Technical Reports Server (NTRS)
Kiris, Cetin; Rogers, Stuart; Kwak, Dochan; Chang, I.-DEE
1991-01-01
The extension of computational fluid dynamics techniques to artificial heart flow simulations is illustrated. Unsteady incompressible Navier-Stokes equations written in 3-D generalized curvilinear coordinates are solved iteratively at each physical time step until the incompressibility condition is satisfied. The solution method is based on the pseudo compressibility approach and uses an implicit upwind differencing scheme together with the Gauss-Seidel line relaxation method. The efficiency and robustness of the time accurate formulation of the algorithm are tested by computing the flow through model geometries. A channel flow with a moving indentation is computed and validated with experimental measurements and other numerical solutions. In order to handle the geometric complexity and the moving boundary problems, a zonal method and an overlapping grid embedding scheme are used, respectively. Steady state solutions for the flow through a tilting disk heart valve was compared against experimental measurements. Good agreement was obtained. The flow computation during the valve opening and closing is carried out to illustrate the moving boundary capability.
Canazei, Markus; Pohl, Wilfried; Bauernhofer, Kathrin; Papousek, Ilona; Lackner, Helmut K; Bliem, Harald R; Marksteiner, Josef; Weiss, Elisabeth M
2017-01-01
Light interventions typically exert their mood-related effects during morning bright light exposures over several weeks. Evidence about immediate ambient room light effects on depressed individuals is still sparse. The present study aimed at examining the acute effects of a single moderately bright room light exposure on mood, and behavioural and cardiac stress reactions of mildly depressed geriatric inpatients during a short cognitive stimulation and while resting. Twenty-one inpatients were tested in a balanced cross-over design on 2 consecutive days under either conventional room light (standard light) or artificial sunlight conditions for 30 min. Room illumination was implemented with an artificial skylight, which perfectly imitated solar indoor illumination (e.g., cloudless sky and bright artificial sun). Light-induced changes of mood, heart rate, and heart rate variability were recorded while performing a perseveration test (acted as cognitive stimulation) twice. Additionally, light-related behaviour was observed during a resting period between the cognitive tests and various subjective ratings were obtained. Compared to standard light, exposure to artificial sunlight had a subjective calming effect over time (p = 0.029) as well as decreased heart rate and increased vagal tone (root mean squared of successive inter-beat intervals), both under cognitive workload and in resting conditions. Effect sizes of reported cardiac reactions were large. Cognitive variables were not influenced by light. Additionally, under the higher corneal illuminance of the artificial sunlight, patients perceived stronger glare (p = 0.030) and kept their eyes closed for longer times (p = 0.033) during the resting period. However, patients did not avoid bright light exposure while resting but voluntarily stayed within the area directly lit by the artificial sun nearly all the time (97%). To our knowledge, this study for the first time demonstrated immediate psychophysiological effects of a single, short room light exposure in mildly depressed geriatric inpatients during a short cognitive stimulation and while resting. The findings complement reported evidence on immediate alerting and mood-related effects of bright light exposures. © 2017 S. Karger AG, Basel.
Wotke, Jiri; Homolka, Pavel; Vasku, Jaromír; Dobsak, Petr; Palanova, Petra; Mrkvicova, Veronika; Konecny, Petr; Soska, Vladimir; Pohanka, Michal; Novakova, Marie; Yurimoto, Terumi; Saito, Itsuro; Inoue, Yusuke; Isoyama, Takashi; Abe, Yusuke
2016-12-01
Histopathological analysis can provide important information in long-term experiments with total artificial heart (TAH). Recently, a new type of blood pump, the helical flow total artificial heart (HF-TAH) was developed. This study aimed to investigate the changes in selected vital organs in animal experiments with implanted HF-TAH. Samples from lung, liver, and kidneys from two female goats (No. 1301 and No. 1304) with implanted HF-TAH were analyzed. Tissue samples were fixed in 10% formaldehyde and 4 µm thick transverse sections were stained with hematoxylin-eosin (HE). Additional staining was done for detection of connective tissue (Masson-Goldner stain) and for detection of iron (hemosiderin) deposits (Perls stain). Sections were scanned at 100× and 500× magnification with a light microscope. Experiment no. 1301 survived 100 days (cause of termination was heavy damage of the right pump); experimental goat no.1304 survived 68 days and was sacrificed due to severe right hydrodynamic bearing malfunction. Histopathological analysis of liver samples proved signs of chronic venostasis with limited focal necrotic zones. Dilated tubules, proteinaceous material in tubular lumen, and hemosiderin deposits were detected in kidney samples. Contamination of the organs by embolized micro-particles was suspected at the autopsy after discovery of visible damage (scratches) of the pump impeller surface (made from titanium alloy) in both experiments. Sporadic deposits of foreign micro-particles (presumably titanium) were observed in most of the analyzed parenchymal organs. However, the described deposits were not in direct connection with inflammatory reactions in the analyzed tissues. Histopathological analysis showed the presence of minimal contamination of the lung, kidney, and liver tissue samples by foreign material (titanium very likely). The analysis showed only limited pathological changes, especially in liver and kidneys, which might be attributed to the influence of artificial perfusion often observed in chronic TAH experiments. © 2016 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.
THE MECHANICAL HEART ON THE MEDICAL HORIZON
Kolff, Jacob; Olsen, Don B.; Kolff, Willem J.
1975-01-01
Progress in materials and design of a total artificial heart has lengthened survival times from 1½ hours in 1958 to 3 months in 1974. During those years various limiting factors were found and analyzed. Remaining limitations encountered in a 3-month survivor were localized thrombosis within the blood chambers and infection along drive lines into the mediastinum. Images PMID:15215913
Shah, Keyur B; Thanavaro, Kristin L; Tang, Daniel G; Quader, Mohammed A; Mankad, Anit K; Tchoukina, Inna; Thacker, Leroy R; Smallfield, Melissa C; Katlaps, Gundars; Hess, Michael L; Cooke, Richard H; Kasirajan, Vigneshwar
2016-11-01
Insufficient data delineate outcomes for Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile 1 patients with the total artificial heart (TAH). We studied 66 consecutive patients implanted with the TAH at our institution from 2006 through 2012 and compared outcome by INTERMACS profile. INTERMACS profiles were adjudicated retrospectively by a reviewer blinded to clinical outcomes. Survival after TAH implantation at 6 and 12 months was 76% and 71%, respectively. INTERMACS profile 1 patients had decreased 6-month survival on the device compared with those in profiles 2-4 (74% vs 95%, log rank: P = .015). For the 50 patients surviving to heart transplantation, the 1-year posttransplant survival was 82%. There was no difference in 1-year survival when comparing patients in the INTERMACS 1 profile with less severe profiles (79% vs 84%; log rank test P = .7; hazard ratio [confidence interval] 1.3 [0.3-4.8]). Patients implanted with the TAH as INTERMACS profile 1 had reduced survival to transplantation compared with less sick profiles. INTERMACS profile at the time of TAH implantation did not affect 1-year survival after heart transplantation. Copyright © 2016 Elsevier Inc. All rights reserved.
4D optical coherence tomography of aortic valve dynamics in a murine mouse model ex vivo
NASA Astrophysics Data System (ADS)
Schnabel, Christian; Jannasch, Anett; Faak, Saskia; Waldow, Thomas; Koch, Edmund
2015-07-01
The heart and its mechanical components, especially the heart valves and leaflets, are under enormous strain during lifetime. Like all highly stressed materials, also these biological components undergo fatigue and signs of wear, which impinge upon cardiac output and in the end on health and living comfort of affected patients. Thereby pathophysiological changes of the aortic valve leading to calcific aortic valve stenosis (AVS) as most frequent heart valve disease in humans are of particular interest. The knowledge about changes of the dynamic behavior during the course of this disease and the possibility of early stage diagnosis could lead to the development of new treatment strategies and drug-based options of prevention or therapy. ApoE-/- mice as established model of AVS versus wildtype mice were introduced in an ex vivo artificially stimulated heart model. 4D optical coherence tomography (OCT) in combination with high-speed video microscopy were applied to characterize dynamic behavior of the murine aortic valve and to characterize dynamic properties during artificial stimulation. OCT and high-speed video microscopy with high spatial and temporal resolution represent promising tools for the investigation of dynamic behavior and their changes in calcific aortic stenosis disease models in mice.
Artificial organs and transplantation.
Splendiani, G; Cipriani, S; Vega, A; Casciani, C U
2003-05-01
Nowadays artificial devices are not able to totally and undefinitely replace the loss of function of all vital organs and artificial organs can be used only to bridge the time to transplantation, which must be considered the first choice in the therapeutical approach for many chronic diseases. Since general population aging process is leading to an increase of organ demand, the gap between performed and requested transplantation is hard to fill. Xenotransplantation is nowadays only an experimental alternative solution and we have to do our best using available artificial organs to increase and improve the survival of patients waiting for transplantation. In this meeting we particularly dealt about organ function replacing therapy, especially regarding the kidney, heart, liver, pancreas and ear.
... medicine. Severe cases require additional treatment, such as: Artificial pacemaker. The electronic device is placed under the skin on your chest. It helps your heart maintain a regular beat. Cardiac defibrillation. A brief ...
Heat Generation in Axial and Centrifugal Flow Left Ventricular Assist Devices.
Yost, Gardner; Joseph, Christine Rachel; Royston, Thomas; Tatooles, Antone; Bhat, Geetha
Despite increasing use of left ventricular assist devices (LVADs) as a surgical treatment for advanced heart failure in an era of improved outcomes with LVAD support, the mechanical interactions between these pumps and the cardiovascular system are not completely understood. We utilized an in vitro mock circulatory loop to analyze the heat production incurred by operation of an axial flow and centrifugal flow LVAD. A HeartMate II and a HeartWare HVAD were connected to an abbreviated flow loop and were implanted in a viscoelastic gel. Temperature was measured at the surface of each LVAD. Device speed and fluid viscosity were altered and, in the HeartMate II, as artificial thrombi were attached to the inflow stator, impeller, and outflow stator. The surface temperatures of both LVADs increased in all trials and reached a plateau within 80 minutes of flow initiation. Rate of heat generation and maximum system temperature were greater when speed was increased, when viscosity was increased, and when artificial thrombi were attached to the HeartMate II impeller. Normal operation of these two widely utilized LVADs results in appreciable heat generation in vitro. Increased pump loading resulted in more rapid heat generation, which was particularly severe when a large thrombus was attached to the impeller of the HeartMate II. While heat accumulation in vivo is likely minimized by greater dissipation in the blood and soft tissues, focal temperature gains with the pump housing of these two devices during long-term operation may have negative hematological consequences.
Shah, Rachit; Patel, Dhavalkumar B; Mankad, Anit K; Rennyson, Stephen L; Tang, Daniel G; Quader, Mohammed A; Smallfield, Melissa C; Kasirajan, Vigneshwar; Shah, Keyur B
2016-01-01
Pulmonary hypertension (PH) among heart transplant recipients is associated with an increased risk of mortality. Pulmonary hemodynamics improves after left ventricular assist device (LVAD) implantation; however, the impact of PH before total artificial heart (TAH) implantation on posttransplant hemodynamics and survival is unknown. This is a single center retrospective study aimed to evaluate the impact of TAH implantation on posttransplant hemodynamics and mortality in two groups stratified according to severity of PH: high (≥3 Woods units [WU]) and low (<3 WU) baseline pulmonary vascular resistance (PVR). Hemodynamic data were obtained from right heart catheterization performed at baseline (before TAH) and posttransplant at 1 and 12 months. Patients in the high PVR group (n = 12) experienced improvement in PVR (baseline = 4.31 ± 0.7; 1-month = 1.69 ± 0.7, p < 0.001; 12-month = 48 ± 0.9, p < 0.001) and transpulmonary gradient (baseline = 15.8 ± 3.3; 1-month = 11.57 ± 5.0, p = 0.07; 12-month = 8.50 ± 4.0, p = 0.008) after transplantation, reaching similar values as the low PVR group at 12 months. The filling pressures improved in the high PVR group after heart transplantation (HT), but remained elevated. There was no significant difference in survival between the two groups at 12 months follow-up. Patients with high PVR who are bridged to transplant with TAH had improvement in PVR at 12 months after transplant, and the degree of PVR did not impact posttransplant survival.
A Research Program on Artificial Intelligence in Process Engineering.
ERIC Educational Resources Information Center
Stephanopoulos, George
1986-01-01
Discusses the use of artificial intelligence systems in process engineering. Describes a new program at the Massachusetts Institute of Technology which attempts to advance process engineering through technological advances in the areas of artificial intelligence and computers. Identifies the program's hardware facilities, software support,…
... re also more likely to recover quickly. Bacterial endocarditis. Bacteria occasionally can spread through your bloodstream and ... as a damaged or artificial heart valve. Bacterial endocarditis is associated with glomerular disease, but the connection ...
Bazylev, V V; Nemchenko, E V; Karnakhin, V A; Pavlov, A A; Mikulyak, A I
2016-01-01
Advantages and shortcomings of aortocoronary bypass grafting on the beating heart and in the conditions of artificial circulation (AC) have long been discussed. The data on patency of bypass grafts in the remote period are indicative of comparable results of operations with and without AC or advantages of using AC. In order to determine benefits of each method it is necessary to reveal intraoperative predictors of bypass grafts occlusion in the remote period. We analyzed the results of ultrasound flowmetry of the blood flow through the left internal thoracic artery during bypass grafting of the anterior descending artery with the use of AC and on the beating heart. A retrospective study included a total of 352 patients subdivided into 2 groups: Group One was composed of 120 patients undergoing surgery in the conditions of AC and Group Two comprised 232 patients subjected to similar operations on the beating heart. Blood flow was measured with the help of flowmeter VeryQ MediStim® after termination of AC and inactivation of heparin by protamine, with systolic pressure of 100-110 mm Hg. There were no statistically significant differences between the groups by the diameter and degree of stenosis of the anterior descending artery, diameter of the left internal thoracic artery. The mean volumetric blood flow velocity (Qmean) along the shunts in Group One was higher (p=0.01). No statistically significant differences by the pulsatility index (PI) between the groups were revealed (p=0.2). A conclusion was drawn that coronary bypass grafting of the anterior descending artery by the left internal thoracic artery in the conditions of artificial circulation made it possible to achieve higher volumetric velocity of blood flow through the conduit as compared with operations on the beating heart, with similar resistance index. The immediate results of the operations with the use of the both techniques did not differ.
Wireless power transfer for a pacemaker application.
Vulfin, Vladimir; Sayfan-Altman, Shai; Ianconescu, Reuven
2017-05-01
An artificial pacemaker is a small medical device that uses electrical impulses, delivered by electrodes contracting the heart muscles, to regulate the beating of the heart. The pacemaker is implanted under the skin, and uses for many years regular non-rechargeable batteries. However, the demand for rechargeable batteries in pacemakers increased, and the aim of this work is to design an efficient charging system for pacemakers.
Kim, H C; Khanwilkar, P S; Bearnson, G B; Olsen, D B
1997-01-01
An automatic physiological control system for the actively filled, alternately pumped ventricles of the volumetrically coupled, electrohydraulic total artificial heart (EHTAH) was developed for long-term use. The automatic control system must ensure that the device: 1) maintains a physiological response of cardiac output, 2) compensates for an nonphysiological condition, and 3) is stable, reliable, and operates at a high power efficiency. The developed automatic control system met these requirements both in vitro, in week-long continuous mock circulation tests, and in vivo, in acute open-chested animals (calves). Satisfactory results were also obtained in a series of chronic animal experiments, including 21 days of continuous operation of the fully automatic control mode, and 138 days of operation in a manual mode, in a 159-day calf implant.
Guidi, G; Pettenati, M C; Miniati, R; Iadanza, E
2012-01-01
In this paper we describe an Heart Failure analysis Dashboard that, combined with a handy device for the automatic acquisition of a set of patient's clinical parameters, allows to support telemonitoring functions. The Dashboard's intelligent core is a Computer Decision Support System designed to assist the clinical decision of non-specialist caring personnel, and it is based on three functional parts: Diagnosis, Prognosis, and Follow-up management. Four Artificial Intelligence-based techniques are compared for providing diagnosis function: a Neural Network, a Support Vector Machine, a Classification Tree and a Fuzzy Expert System whose rules are produced by a Genetic Algorithm. State of the art algorithms are used to support a score-based prognosis function. The patient's Follow-up is used to refine the diagnosis.
... Also known as ICD ) - An ICD is a battery-powered device placed under the skin that keeps ... Pacemaker (Also known as Artificial Pacemaker) - A small battery-operated device that helps the heart beat in ...
77 FR 27737 - Procurement List Proposed Additions
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
..., pictures, wall art, artificial plants, light fixtures, globes/lenses, trophies/display cases, drapes... Forces Medical Examiner System, Building 115, 115 Purple Heart Drive, Dover AFB, DE. NPA: The Chimes, Inc...
... with an artificial valve (this is called the Ross Procedure). This procedure may be useful for people ... valve that does not close all the way will allow blood to leak backwards. This is called ...
Helping the Library Reach Out to the Future
... the students asked questions and explored exhibits featuring artificial body parts and recent examples of medical breakthroughs. They saw and touched heart stents, pacemakers, oxygenators (old and new), a coronary ...
Rimmbach, Christian; Jung, Julia J.; David, Robert
2015-01-01
Treatment of the “sick sinus syndrome” is based on artificial pacemakers. These bear hazards such as battery failure and infections. Moreover, they lack hormone responsiveness and the overall procedure is cost-intensive. “Biological pacemakers” generated from PSCs may become an alternative, yet the typical content of pacemaker cells in Embryoid Bodies (EBs) is extremely low. The described protocol combines “forward programming” of murine PSCs via the sinus node inducer TBX3 with Myh6-promoter based antibiotic selection. This yields cardiomyocyte aggregates consistent of >80% physiologically functional pacemaker cells. These “induced-sinoatrial-bodies” (“iSABs”) are spontaneously contracting at yet unreached frequencies (400-500 bpm) corresponding to nodal cells isolated from mouse hearts and are able to pace murine myocardium ex vivo. Using the described protocol highly pure sinus nodal single cells can be generated which e.g. can be used for in vitro drug testing. Furthermore, the iSABs generated according to this protocol may become a crucial step towards heart tissue engineering. PMID:25742394
Infections in Patients with a Total Artificial Heart Are Common but Rarely Fatal.
Hidalgo, Luis F; Shah, Keyur B; Cooke, Richard H; Tang, Daniel G; Kasirajan, Vigneshwar; Cooper, Howard A; Aronow, Wilbert S
Patients who received a total artificial heart (TAH) at Virginia Commonwealth University (VCU) between January 1, 2010 and December 31, 2011 were identified from the VCU Mechanical Circulatory Support Clinical Database. Retrospective data extraction from the medical records was performed from the time of TAH implantation until heart transplantation or death. Infections were classified as confirmed or suspected. Twenty-seven men and five women, mean age 49.5 years (range 24-68 years) received a TAH. The mean duration of TAH support was 225 days (range 1-1,334 days). Of the 32 patients, 4 (12.5%) died and 28 (87.5 %) underwent heart transplantation. Causes of death were pneumonia (n = 1), TAH malfunction (n = 1), refractory cardiogenic shock (n = 1), and respiratory failure (n = 1). Seventy documented and 13 suspected infections developed in 25 patients (78%). The most common sources of infection were urinary tract (n = 26), respiratory tract (n = 18), and bloodstream (n = 11). There were five pump infections and two driveline infections. The number of infections per patient ranged from 0 to 10. Sixteen different pathogens were identified; the most common were: Klebsiella pneumoniae (n = 15), coagulase-negative Staphylococci (n = 10), Enterococcus species (n = 9), and Enterobacter species (n = 8). Mortality directly attributable to infection was infrequent.
Lee, H S; Rho, Y R; Park, C Y; Hwang, C M; Kim, W G; Sun, K; Choi, M J; Lee, K K; Cheong, J T; Shim, E B; Min, B G
2002-06-01
A moving actuator type pump has been developed as a multifunctional Korean artificial heart (AnyHeart). The pump consists of a moving actuator as an energy converter, right and left sacs, polymer (or mechanical) valves, and a rigid polyurethane housing. The actuator containing a brushless DC motor moves back and forth on an epicyclical gear train to produce a pendular motion, which compresses both sacs alternately. Of its versatile functions of ventricular assist device and total artificial heart use, we have evaluated the system performance as a single or biventricular assist device through in vitro and in vivo experiments. Pump performance and anatomical feasibility were tested using various animals of different sizes. In the case of single ventricular assist device (VAD) use, one of the sacs remained empty and a mini-compliance chamber was attached to either an outflow or inflow port of the unused sac. The in vitro and in vivo studies show acceptable performance and pump behavior. Further extensive study is required to proceed to human application.
Conversion of the CALAP (Computer Aided Landform Analysis Program) Program from FORTRAN to DUCK.
1986-09-01
J’ DUCK artificial intelligence logic programming 20 AVrACT (Cthm m reerse stabN ameeaaW idelfr by block mbae) An expert advisor program named CALAP...original program was developed in FORTRAN on an HP- 1000, a mirticomputer. CALAP was reprogrammed in an Artificial Intelligence (AI) language called DUCK...the Artificial Intelligence Center, U.S. Army Engineer Topographic Laboratory, Fort Belvoir. Z" I. S. n- Page 1 I. Introduction An expert advisor
Wireless patient monitoring system for a moving-actuator type artificial heart.
Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G
2006-10-01
In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.
9 CFR 352.7 - Marking inspected products.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., exotic animal tongues, and exotic animal hearts. EC11SE91.031 (2) For application to exotic animal calf... used on shipping containers, bond labels, artificial casings, and other articles with the approval of...
What Is a Total Artificial Heart?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
9 CFR 352.7 - Marking inspected products.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., exotic animal tongues, and exotic animal hearts. EC11SE91.031 (2) For application to exotic animal calf... used on shipping containers, bond labels, artificial casings, and other articles with the approval of...
Dement'eva, I I; Morozov, Iu A; Charnaia, M A
2013-01-01
125 patients after cardiac surgery operated on with the use of artificial blood circulation (ABC) were followed-up. Blood levels of cardiac protein, binding aliphatic acids and troponin 1 and 3 days after the operation were registered. The study showed that aorta clamping more then 90 minutes and hypothermic perfusion regimen influence cardiomyocites negatively. The state of "surgical trauma" and reperfusional myocardium damage was approximately the same during aortic surgery, myocardium revascularization with the use of aortic clamping and cardioplegia, and correction of the acquired heart disease, according to the dynamics of the studied proteins in blood. The minimal blood level of cardiac protein, binding aliphatic acids after coronary by-pass surgery on the working heart witnesses about negative influence of crystalloid hypothermic cardioplegia on coronary microcirculation.
Basta, Lofty L
2003-01-01
The Multicenter Automatic Defibrillator Implantation Trial (MADIT II) investigators assert that their results justify the placement of artificial implantable defibrillator cardioverter devices in patients aged 75 years and older with prior myocardial infarction and left ventricular dysfunction (ejection fraction of 30 or less). The authors claim that the results of the trial do not justify this conclusion. The majority of patients were male (84%) and aged 64+/-10 years. Also, 2.8% of patients assigned to the defibrillator group and 1.5% had their device removed. Of the latter subgroup, nine patients (1.3%) received a heart transplant. Twelve had their artificial implantable defibrillator cardioverter device deactivated mostly because of terminal illness. Although the study results show a significant reduction in mortality over the control group (absolute reduction=5.6%), almost the same percentage required hospitalization because of manifestation of congestive heart failure (absolute value 5%; p=0.09). Also, 1.8% had lead problems, 0.7% had infections, and the benefits were only seen after the first year. Caution is needed before the results of this study are applied to a much older cohort comprised mainly of women in whom heart transplant is contraindicated and who have multiple health problems, including cognitive impairment. Artificial implantable cardioverter/defibrillator devices are expensive and this study's results need to be duplicated in other comparable cohorts.
Okamoto, Eiji; Watanabe, Kazuya; Hashiba, Kunihiro; Inoue, Taku; Iwazawa, Eichi; Momoi, Masato; Hashimoto, Takuya; Mitamura, Yoshinori
2002-01-01
An implantable secondary battery is one of the key components in a total artificial heart system. Because a 2 year cycle life is required, the cycle life of the secondary battery as well as its charge and discharge properties are important parameters for selection of an appropriate battery. We carried out cycle life tests on four kinds of rechargeable batteries (a Ni-MH secondary battery, a Ni-Cd secondary battery, a Li-ion battery with a graphite anode, and a Li-ion battery with a nongraphitizable carbon electrode) to determine their suitability as implanted back-up batteries. Each of the batteries was charge/discharge cycled at 37 degrees C to 39 degrees C using a charge current of 1 C ampere, and they were each fully discharged under either pulsatile discharge loads, which mimicked pulsatile operation, or a nonpulsatile load equivalent to the average of the pulsatile loads. The two Li-ion batteries made by different manufacturers both met the minimum requirement of cycle life of more than 1,500 cycles, considering safety coefficient regardless of the discharge pattern. In addition, the temperature increase of these Li-ion batteries (3 degrees C) was lower than that of Ni-Cd and Ni-MH batteries (15-25 degrees C). Out of these four batteries, the two Li-ion batteries are the most suitable for use in a totally implantable artificial heart system.
Investigation of the Durability of a Diaphragm for a Total Artificial Heart.
Gräf, Felix; Rossbroich, Ralf; Finocchiaro, Thomas; Steinseifer, Ulrich
2016-10-01
One of the most critical components regarding the durability of the ReinHeart total artificial heart (TAH) is its biocompatible diaphragm, which separates the drive unit from the ventricles. Hence, a durability tester was designed to investigate its required 5-year lifetime. The aim of this study was to prove the validity of accelerated testing of the polyurethane diaphragm. The durability tester allows simultaneous testing of 12 diaphragms and mimics physiological conditions. To accelerate the time of testing, it operates with an increased speed at a frequency of 8 Hz. To prove the correctness of this acceleration, a servo-hydraulic testing machine was used to study the effect of different frequencies and their corresponding loads. Thereby the viscoelastic behavior of the polyurethane was investigated. Additionally, high-speed video measurements were performed. The force against frequency and the high-speed video measurements showed constant behavior. In the range of 1-10 Hz, the maximum resulting forces varied by 3%, and the diaphragm movement was identical. Frequencies below 10 Hz allow a valid statement of the diaphragm's mechanical durability. Viscoelasticity of the polyurethane in the considered frequency-range is negligible. The accelerated durability test is applicable to polyurethane diaphragms, and the results are applicable to TAH use. The reliability of the diaphragm for a lifetime of 5 years was found to be 80% with a confidence of 62%. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Mohamed, Mohamed A; Islas, Jose F; Schwartz, Robert J; Birla, Ravi K
Development of tissue-engineered hearts for treatment of myocardial infarction or biologic pacemakers has been hindered by the production of mostly arrhythmic or in-synergistic constructs. Electrical stimulation (ES) of these constructs has been shown to produce tissues with greater twitch force and better adrenergic response. To further our understanding of the mechanisms underlying the effect of ES, we fabricated a bioreactor capable of delivering continuous or intermittent waveforms of various types to multiple constructs simultaneously. In this study, we examined the effect of an intermittent biphasic square wave on our artificial heart muscle (AHM) composed of neonatal rat cardiac cells and fibrin gel. Twitch forces, spontaneous contraction rates, biopotentials, gene expression profiles, and histologic observations were examined for the ES protocol over a 12 day culture period. We demonstrate improved consistency between samples for twitch force and contraction rate, and higher normalized twitch force amplitudes for electrically stimulated AHMs. Improvements in electrophysiology within the AHM were noted by higher conduction velocities and lower latency in electrical response for electrically stimulated AHMs. Genes expressing key electrophysiologic and structural markers peaked at days 6 and 8 of culture, only a few days after the initiation of ES. These results may be used for optimization strategies to establish protocols for producing AHMs capable of replacing damaged heart tissue in either a contractile or electrophysiologic capacity. Optimized AHMs can lead to alternative treatments to heart failure and alleviate the limited donor supply crisis.
Mohamed, Mohamed A; Islas, Jose F; Schwartz, Robert J; Birla, Ravi K
2016-01-01
Development of tissue-engineered hearts for treatment of myocardial infarction or biological pacemakers has been hindered by the production of mostly arrhythmic or in-synergistic constructs. Electrical stimulation (ES) of these constructs has been shown to produce tissues with greater twitch force and better adrenergic response. In order to further our understanding of the mechanisms underlying the effect of ES, we fabricated a bioreactor capable of delivering continuous or intermittent waveforms of various types to multiple constructs simultaneously. In this study, we examined the effect of an intermittent biphasic square wave on our artificial heart muscle (AHM) composed of neonatal rat cardiac cells and fibrin gel. Twitch forces, spontaneous contraction rates, biopotentials, gene expression profiles, and histological observations were examined for the ES protocol over a 12 day culture period. We demonstrate improved consistency between samples for twitch force and contraction rate, and higher normalized twitch force amplitudes for electrically stimulated AHM. Improvements in electrophysiology within the AHM was noted by higher conduction velocities and lower latency in electrical response for electrically stimulated AHM. Genes expressing key electrophysiological and structural markers peaked at days 6 and 8 of culture, only a few days after the initiation of ES. These results may be used for optimization strategies to establish protocols for producing AHM capable of replacing damaged heart tissue in either a contractile or electrophysiological capacity. Optimized AHM can lead to alternative treatments to heart failure and alleviate the limited donor supply crisis. PMID:28459744
Heart Health Education in the Young
ERIC Educational Resources Information Center
Sunseri, Albert J.; Kruc, Joan E.
1978-01-01
The focus of this article is to examine selected approaches to heart health education, to describe a program the Heart Attack Prevention Program of the Chicago Heart Association is designing and implementing in heart health education, and to make recommendations concerning future development of health education programs by other agencies. (Author)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watanabe, Yoshimasa; Itoh, Takeo, E-mail: titoh@med.nagoya-cu.ac.jp; Shiraishi, Hiroaki
The organophosphorus compound sarin irreversibly inhibits acetylcholinesterase. We examined the acute cardiovascular effects of a sarin-like organophosphorus agent, bis(isopropyl methyl)phosphonate (BIMP), in anaesthetized, artificially ventilated rats. Intravenous administration of BIMP (0.8 mg/kg; the LD50 value) induced a long-lasting increase in blood pressure and tended to increase heart rate. In rats pretreated with the non-selective muscarinic-receptor antagonist atropine, BIMP significantly increased both heart rate and blood pressure. In atropine-treated rats, hexamethonium (antagonist of ganglionic nicotinic receptors) greatly attenuated the BIMP-induced increase in blood pressure without changing the BIMP-induced increase in heart rate. In rats treated with atropine plus hexamethonium, intravenous phentolaminemore » (non-selective α-adrenergic receptor antagonist) plus propranolol (non-selective β-adrenergic receptor antagonist) completely blocked the BIMP-induced increases in blood pressure and heart rate. In atropine-treated rats, the reversible acetylcholinesterase inhibitor neostigmine (1 mg/kg) induced a transient increase in blood pressure, but had no effect on heart rate. These results suggest that in anaesthetized rats, BIMP induces powerful stimulation of sympathetic as well as parasympathetic nerves and thereby modulates heart rate and blood pressure. They may also indicate that an action independent of acetylcholinesterase inhibition contributes to the acute cardiovascular responses induced by BIMP. - Highlights: • A sarin-like agent BIMP markedly increased blood pressure in anaesthetized rats. • Muscarinic receptor blockade enhanced the BIMP-induced increase in blood pressure. • Ganglionic nicotinic receptor blockade attenuated the BIMP-induced response. • Blockade of α- as well as β-receptors attenuated the BIMP-induced response.« less
A bioprosthetic total artificial heart for end-stage heart failure: Results from a pilot study.
Latrémouille, Christian; Carpentier, Alain; Leprince, Pascal; Roussel, Jean-Christian; Cholley, Bernard; Boissier, Elodie; Epailly, Eric; Capel, Antoine; Jansen, Piet; Smadja, David M
2018-01-01
The electro-hydraulically actuated Carmat total artificial heart (C-TAH) is designed to replace the heart in patients with end-stage heart failure, either as bridge to transplant or destination therapy. It provides pulsatile flow and contains bio-prosthetic blood contacting materials. A clinical feasibility study was conducted to evaluate the C-TAH safety and performance. Hospitalized patients, at imminent risk of death from irreversible biventricular failure despite optimal medical management, and not eligible for transplant or eligible but on extracorporeal life support, were enrolled. The primary endpoint was 30-days survival. Four patients were implanted with the C-TAH, three as destination therapy (ages 76, 68, 74) and one as bridge to transplant (age 58). They had implant times of 74, 270, 254 and 20 days respectively. All patients were free from hemolysis, clinical neurologic events, clinical evidence of thrombus and device-related infections. Hemodynamic and physical recovery allowed two patients to be discharged home for a cumulative duration of 7 months. The anticoagulation management strategy comprised initial unfractionated heparin, from postoperative day 2, followed by low molecular weight heparin and aspirin. An increased D-dimer level was observed in all patients during months 1 to 4. Temporary suspension of heparin anticoagulation resulted in thrombocytopenia and increased fibrin monomer, reversed by resuming anticoagulation with heparin. Causes of death were device-related (2 cases), respiratory failure and multi-organ failure. Preliminary clinical results with the C-TAH demonstrated good safety and performance profiles in patients suffering from biventricular failure, which need to be confirmed in a pivotal study. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Gould van Praag, Cassandra D; Garfinkel, Sarah N; Sparasci, Oliver; Mees, Alex; Philippides, Andrew O; Ware, Mark; Ottaviani, Cristina; Critchley, Hugo D
2017-03-27
Naturalistic environments have been demonstrated to promote relaxation and wellbeing. We assess opposing theoretical accounts for these effects through investigation of autonomic arousal and alterations of activation and functional connectivity within the default mode network (DMN) of the brain while participants listened to sounds from artificial and natural environments. We found no evidence for increased DMN activity in the naturalistic compared to artificial or control condition, however, seed based functional connectivity showed a shift from anterior to posterior midline functional coupling in the naturalistic condition. These changes were accompanied by an increase in peak high frequency heart rate variability, indicating an increase in parasympathetic activity in the naturalistic condition in line with the Stress Recovery Theory of nature exposure. Changes in heart rate and the peak high frequency were correlated with baseline functional connectivity within the DMN and baseline parasympathetic tone respectively, highlighting the importance of individual neural and autonomic differences in the response to nature exposure. Our findings may help explain reported health benefits of exposure to natural environments, through identification of alterations to autonomic activity and functional coupling within the DMN when listening to naturalistic sounds.
Gould van Praag, Cassandra D.; Garfinkel, Sarah N.; Sparasci, Oliver; Mees, Alex; Philippides, Andrew O.; Ware, Mark; Ottaviani, Cristina; Critchley, Hugo D.
2017-01-01
Naturalistic environments have been demonstrated to promote relaxation and wellbeing. We assess opposing theoretical accounts for these effects through investigation of autonomic arousal and alterations of activation and functional connectivity within the default mode network (DMN) of the brain while participants listened to sounds from artificial and natural environments. We found no evidence for increased DMN activity in the naturalistic compared to artificial or control condition, however, seed based functional connectivity showed a shift from anterior to posterior midline functional coupling in the naturalistic condition. These changes were accompanied by an increase in peak high frequency heart rate variability, indicating an increase in parasympathetic activity in the naturalistic condition in line with the Stress Recovery Theory of nature exposure. Changes in heart rate and the peak high frequency were correlated with baseline functional connectivity within the DMN and baseline parasympathetic tone respectively, highlighting the importance of individual neural and autonomic differences in the response to nature exposure. Our findings may help explain reported health benefits of exposure to natural environments, through identification of alterations to autonomic activity and functional coupling within the DMN when listening to naturalistic sounds. PMID:28345604
Wan, W K; Campbell, G; Zhang, Z F; Hui, A J; Boughner, D R
2002-01-01
Although bioprosthetic heart valves offer the benefits of a natural opening and closing, better hemodynamics, and avoidance of life-long anticoagulant therapy, they nevertheless tend to fail in 10-15 years from tears and calcification. Several authors, including the present ones, have identified the rigid stent as a factor contributing to these failures. The ultimate solution is an artificial heart valve that has mechanical properties that allow it to move in conformity with the aortic root during the cardiac cycle, has superior hemodynamics, is nonthrombogenic, will last more than 20 years, and mitigates the need for anticoagulants. We have identified a polymer, polyvinyl alcohol (PVA) hydrogel, that has mechanical properties similar to soft tissue. The purpose of this research is to match the tensile properties of PVA to the porcine aortic root and to fabricate a stent prototype for a bioprosthetic heart valve with the use of the PVA hydrogel. Specimens of 15% w/w PVA were prepared by processing through 1-6 cycles of freezing (-20 degrees C) at 0.2 degrees C/min freeze rate and thawing (+20 degrees C) at different thawing rates (0.2 degrees C/min and 1 degrees C/min), for different holding times (1 and 6 h) at -20 degrees C. Subsequently tensile tests and stress-relaxation tests were conducted on the specimens. The different holding times at -20 degrees C demonstrated no difference in the result. The slower thawing rate improved the tensile properties but did not produce significant changes on the stress-relaxation properties. The nonlinear stress-strain curve for the PVA after the fourth freeze-thaw cycle matched the porcine aortic root within the physiological pressure range. The stress-relaxation curve for PVA also approximated the shape of the aortic root. The complex geometry of an artificial heart valve stent was successfully injection molded. These results, in combination with other preliminary findings for biocompatibility and fatigue behavior, suggest that PVA hydrogel is a promising biomaterial for implants, catheters, and artificial skin. Copyright 2002 Wiley Periodicals, Inc.
78 FR 38867 - Gastroenterology-Urology Devices; Reclassification of Implanted Blood Access Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... artificial kidney system for the treatment of patients with renal failure or toxemic conditions and provides... into the heart or blood vessel could damage tissues and result in injuries. Hemolysis. Turbulence or...
High reliability linear drive device for artificial hearts
NASA Astrophysics Data System (ADS)
Ji, Jinghua; Zhao, Wenxiang; Liu, Guohai; Shen, Yue; Wang, Fangqun
2012-04-01
In this paper, a new high reliability linear drive device, termed as stator-permanent-magnet tubular oscillating actuator (SPM-TOA), is proposed for artificial hearts (AHs). The key is to incorporate the concept of two independent phases into this linear AH device, hence achieving high reliability operation. The fault-tolerant teeth are employed to provide the desired decoupling phases in magnetic circuit. Also, as the magnets and the coils are located in the stator, the proposed SPM-TOA takes the definite advantages of robust mover and direct-drive capability. By using the time-stepping finite element method, the electromagnetic characteristics of the proposed SPM-TOA are analyzed, including magnetic field distributions, flux linkages, back- electromotive forces (back-EMFs) self- and mutual inductances, as well as cogging and thrust forces. The results confirm that the proposed SPM-TOA meets the dimension, weight, and force requirements of the AH drive device.
Incompressible viscous flow computations for the pump components and the artificial heart
NASA Technical Reports Server (NTRS)
Kiris, Cetin
1992-01-01
A finite-difference, three-dimensional incompressible Navier-Stokes formulation to calculate the flow through turbopump components is utilized. The solution method is based on the pseudocompressibility approach and uses an implicit-upwind differencing scheme together with the Gauss-Seidel line relaxation method. Both steady and unsteady flow calculations can be performed using the current algorithm. In this work, the equations are solved in steadily rotating reference frames by using the steady-state formulation in order to simulate the flow through a turbopump inducer. Eddy viscosity is computed by using an algebraic mixing-length turbulence model. Numerical results are compared with experimental measurements and a good agreement is found between the two. Included in the appendix is a paper on incompressible viscous flow through artificial heart devices with moving boundaries. Time-accurate calculations, such as impeller and diffusor interaction, will be reported in future work.
BNP and congestive heart failure.
Cowie, Martin R; Mendez, Gustavo F
2002-01-01
Brain natriuretic peptide (BNP), a peptide hormone secreted chiefly by ventricular myocytes, plays a key role in volume homeostasis. The plasma concentration of BNP is raised in various pathological states, especially heart failure. Many studies suggest that measurement of plasma BNP has clinical utility for excluding a diagnosis of heart failure in patients with dyspnea or fluid retention and for providing prognostic information in those with heart failure or other cardiac disease. It may also be of value in identifying patients after myocardial infarction in whom further assessment of cardiac function is likely to be worthwhile. Preliminary evidence suggests that measuring the plasma concentration of BNP may be useful in fine tuning therapy for heart failure. Artificially raising the circulating levels of BNP shows considerable promise as a treatment for heart failure. With simpler assay methods now available, it is likely that many physicians will measure plasma BNP to aid them in the diagnosis, risk stratification, and monitoring of their patients with heart failure or other cardiac dysfunction. Copyright 2002, Elsevier Science.
Time series data analysis using DFA
NASA Astrophysics Data System (ADS)
Okumoto, A.; Akiyama, T.; Sekino, H.; Sumi, T.
2014-02-01
Detrended fluctuation analysis (DFA) was originally developed for the evaluation of DNA sequence and interval for heart rate variability (HRV), but it is now used to obtain various biological information. In this study we perform DFA on artificially generated data where we already know the relationship between signal and the physical event causing the signal. We generate artificial data using molecular dynamics. The Brownian motion of a polymer under an external force is investigated. In order to generate artificial fluctuation in the physical properties, we introduce obstacle pillars fixed to nanostructures. Using different conditions such as presence or absence of obstacles, external field, and the polymer length, we perform DFA on energies and positions of the polymer.
Artificial intelligence in medicine: the challenges ahead.
Coiera, E W
1996-01-01
The modern study of artificial intelligence in medicine (AIM) is 25 years old. Throughout this period, the field has attracted many of the best computer scientists, and their work represents a remarkable achievement. However, AIM has not been successful-if success is judged as making an impact on the practice of medicine. Much recent work in AIM has been focused inward, addressing problems that are at the crossroads of the parent disciplines of medicine and artificial intelligence. Now, AIM must move forward with the insights that it has gained and focus on finding solutions for problems at the heart of medical practice. The growing emphasis within medicine on evidence-based practice should provide the right environment for that change.
Analysis, design, and control of a transcutaneous power regulator for artificial hearts.
Qianhong Chen; Siu Chung Wong; Tse, C K; Xinbo Ruan
2009-02-01
Based on a generic transcutaneous transformer model, a remote power supply using a resonant topology for use in artificial hearts is analyzed and designed for easy controllability and high efficiency. The primary and secondary windings of the transcutaneous transformer are positioned outside and inside the human body, respectively. In such a transformer, the alignment and gap may change with external positioning. As a result, the coupling coefficient of the transcutaneous transformer is also varying, and so are the two large leakage inductances and the mutual inductance. Resonant-tank circuits with varying resonant-frequency are formed from the transformer inductors and external capacitors. For a given range of coupling coefficients, an operating frequency corresponding to a particular coupling coefficient can be found, for which the voltage transfer function is insensitive to load. Prior works have used frequency modulation to regulate the output voltage under varying load and transformer coupling. The use of frequency modulation may require a wide control frequency range which may extend well above the load insensitive frequency. In this paper, study of the input-to-output voltage transfer function is carried out, and a control method is proposed to lock the switching frequency at just above the load insensitive frequency for optimized efficiency at heavy loads. Specifically, operation at above resonant of the resonant circuits is maintained under varying coupling-coefficient. Using a digital-phase-lock-loop (PLL), zero-voltage switching is achieved in a full-bridge converter which is also programmed to provide output voltage regulation via pulsewidth modulation (PWM). A prototype transcutaneous power regulator is built and found to to perform excellently with high efficiency and tight regulation under variations of the alignment or gap of the transcutaneous transformer, load and input voltage.
Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain
2017-08-01
Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Rapid Speed Modulation of a Rotary Total Artificial Heart Impeller.
Kleinheyer, Matthias; Timms, Daniel L; Tansley, Geoffrey D; Nestler, Frank; Greatrex, Nicholas A; Frazier, O Howard; Cohn, William E
2016-09-01
Unlike the earlier reciprocating volume displacement-type pumps, rotary blood pumps (RBPs) typically operate at a constant rotational speed and produce continuous outflow. When RBP technology is used in constructing a total artificial heart (TAH), the pressure waveform that the TAH produces is flat, without the rise and fall associated with a normal arterial pulse. Several studies have suggested that pulseless circulation may impair microcirculatory perfusion and the autoregulatory response and may contribute to adverse events such as gastrointestinal bleeding, arteriovenous malformations, and pump thrombosis. It may therefore be beneficial to attempt to reproduce pulsatile output, similar to that generated by the native heart, by rapidly modulating the speed of an RBP impeller. The choice of an appropriate speed profile and control strategy to generate physiologic waveforms while minimizing power consumption and blood trauma becomes a challenge. In this study, pump operation modes with six different speed profiles using the BiVACOR TAH were evaluated in vitro. These modes were compared with respect to: hemodynamic pulsatility, which was quantified as surplus hemodynamic energy (SHE); maximum rate of change of pressure (dP/dt); pulse power index; and motor power consumption as a function of pulse pressure. The results showed that the evaluated variables underwent different trends in response to changes in the speed profile shape. The findings indicated a possible trade-off between SHE levels and flow rate pulsatility related to the relative systolic duration in the speed profile. Furthermore, none of the evaluated measures was sufficient to fully characterize hemodynamic pulsatility. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Yurimoto, Terumi; Hara, Shintaro; Isoyama, Takashi; Saito, Itsuro; Ono, Toshiya; Abe, Yusuke
2016-09-01
Estimation of pressure and flow has been an important subject for developing implantable artificial hearts. To realize real-time viscosity-adjusted estimation of pressure head and pump flow for a total artificial heart, we propose the table estimation method with quasi-pulsatile modulation of rotary blood pump in which systolic high flow and diastolic low flow phased are generated. The table estimation method utilizes three kinds of tables: viscosity, pressure and flow tables. Viscosity is estimated from the characteristic that differential value in motor speed between systolic and diastolic phases varies depending on viscosity. Potential of this estimation method was investigated using mock circulation system. Glycerin solution diluted with salty water was used to adjust viscosity of fluid. In verification of this method using continuous flow data, fairly good estimation could be possible when differential pulse width modulation (PWM) value of the motor between systolic and diastolic phases was high. In estimation under quasi-pulsatile condition, inertia correction was provided and fairly good estimation was possible when the differential PWM value was high, which was not different from the verification results using continuous flow data. In the experiment of real-time estimation applying moving average method to the estimated viscosity, fair estimation could be possible when the differential PWM value was high, showing that real-time viscosity-adjusted estimation of pressure head and pump flow would be possible with this novel estimation method when the differential PWM value would be set high.
Memory beyond memory in heart beating, a sign of a healthy physiological condition.
Allegrini, P; Grigolini, P; Hamilton, P; Palatella, L; Raffaelli, G
2002-04-01
We describe two types of memory and illustrate each using artificial and actual heartbeat data sets. The first type of memory, yielding anomalous diffusion, implies the inverse power-law nature of the waiting time distribution and the second the correlation among distinct times, and consequently also the occurrence of many pseudoevents, namely, not genuinely random events. Using the method of diffusion entropy analysis, we establish the scaling that would be determined by the real events alone. We prove that the heart beating of healthy patients reveals the existence of many more pseudoevents than in the patients with congestive heart failure.
Yokoyama, Yoshimasa; Kawaguchi, Osamu; Kitao, Takashi; Kimura, Taro; Steinseifer, Ulrich; Takatani, Setsuo
2010-09-01
The ventricular performance is dependent on the drainage effect of rotary blood pumps (RBPs) and the performance of RBPs is affected by the ventricular pulsation. In this study, the interaction between the ventricle and RBPs was examined using the pressure-volume (P-V) diagram of the ventricle and dynamic head pressure-bypass flow (H-Q) curves (H, head pressure: arterial pressure minus ventricular pressure vs. Q, bypass flow) of the RBPs. We first investigated the relationships in a mock loop with a passive fill ventricle, followed by validation in ex vivo animal experiments. An apical drainage cannula with a micro-pressure sensor was especially fabricated to obtain ventricular pressure, while three pairs of ultrasonic crystals placed on the heart wall were used to derive ventricular volume. The mock loop-configured ventricular apical-descending aorta bypass revealed that the external work of the ventricle expressed by the area inside the P-V diagrams (EW(Heart) ) correlated strongly with the area inside dynamic H-Q curves (EW(VAD)), with the coefficients of correlation being R² = 0.869 ∼ 0.961. The results in the mock loop were verified in the ex vivo studies using three Shiba goats (10-25 kg in body weight), showing the correlation coefficients of R² = 0.802 ∼ 0.817. The linear regression analysis indicated that the increase in the bypass flow reduced pulsatility in the ventricle expressed in EW(Heart) as well as in EW(VAD) . Experimental results, both mock loop and animal studies, showed that the interaction between cardiac external work and H-Q performance of RBPs can be expressed by the relationships "EW(Heart) versus EW(VAD) ." The pulsatile nature of the native heart can be expressed in the area underneath the H-Q curves of RBPs EW(VAD) during left heart bypass indicating the status of the level of assistance by RBPs and the native heart function. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Artificial plasma experiments. Chemical release observations associated with the CRRES program
NASA Technical Reports Server (NTRS)
Mende, Stephen B.
1994-01-01
This report submitted is the final report and covers work performed under the contract for the period Apr. 12, 1985 - Dec. 23, 1993. The CRRES program investigated earth plasma environment by active experiments in which metal vapors were injected into the upper atmosphere and magnetosphere. The vapor clouds perturb the ambient ionospheric / magnetospheric environment and the effects could be monitored by passive observing instruments. Our part of the CRRES program, the Artificial Plasma Experiment program, was a ground based and aircraft based investigation to observe artificial chemical releases by optical techniques.
Sweetened Beverage Consumption, Incident Coronary Heart Disease and Biomarkers of Risk in Men
de Koning, Lawrence; Malik, Vasanti S.; Kellogg, Mark D.; Rimm, Eric B.; Willett, Walter C.; Hu, Frank B.
2012-01-01
Background Sugar-sweetened beverage consumption is associated with weight gain and risk of type 2 diabetes. Few studies have tested for a relationship with coronary heart disease (CHD), or intermediate biomarkers. The role of artificially sweetened beverages is also unclear. Methods and Results We performed an analysis of the Health Professionals Follow-up study, a prospective cohort study including 42 883 men. Associations of cumulatively averaged sugar-sweetened (e.g. sodas) and artificially sweetened (e.g. diet sodas) beverage intake with incident fatal and non-fatal CHD (myocardial infarction) were examined using proportional hazard models. There were 3683 CHD cases over 22 years of follow-up. Participants in the top quartile of sugar-sweetened beverage intake had a 20% higher relative risk of CHD than those in the bottom quartile (RR=1.20, 95% CI: 1.09, 1.33, p for trend < 0.01) after adjusting for age, smoking, physical activity, alcohol, multivitamins, family history, diet quality, energy intake, BMI, pre-enrollment weight change and dieting. Artificially sweetened beverage consumption was not significantly associated with CHD (multivariate RR=1.02, 95% CI: 0.93, 1.12, p for trend = 0.28). Adjustment for self-reported high cholesterol, high triglycerides, high blood pressure and diagnosed type 2 diabetes slightly attenuated these associations. Intake of sugar-sweetened but not artificially sweetened beverages was significantly associated with increased triglycerides, CRP, IL6, TNFr1, TNFr2, decreased HDL, Lp(a), and leptin (p values < 0.02). Conclusions Consumption of sugar-sweetened beverages was associated with increased risk of CHD and some adverse changes in lipids, inflammatory factors, and leptin. Artificially sweetened beverage intake was not associated with CHD risk or biomarkers. PMID:22412070
Okamoto, Eiji; Kato, Yoshikuni; Seino, Kazuyuki; Miura, Hidekazu; Shiraishi, Yasuyuki; Yambe, Tomoyuki; Mitamura, Yoshinori
2012-10-01
A transcutaneous communication system (TCS) is a key technology for monitoring and controlling artificial hearts and other artificial organs in the body. In this study, we developed a new TCS that uses the human body as a conductive medium. Direct data exchange provides a higher level of communication security compared to that of wireless methods without physical constraints such as an external wire. The external and internal units of the new TCS each consist mainly of a data transmitter and a data receiver. The data transmitter has an amplitude shift keying (ASK) modulator (carrier frequencies: 4 and 10 MHz) and an electrode. The ASK-modulated data current is led into the body through the electrode, and it flows back to the energy source through the body, the data receiver, and the earth ground that includes all conductors and dielectrics in the environment that are in close proximity to the patient. Performance of the TCS was evaluated by a communication test on the surface of the human body and in an animal experiment using a goat. The TCS was able to transmit data concurrently for 4 weeks between everywhere on the surface of the body and everywhere inside the body under full-duplex communication at a transmission rate of 115 kbps. The power consumption of each TCS unit was 125 mW with an ASK-modulated current of 7 mA (root-mean-square). While further study is required to secure its safety, the newly developed TCS has promise to be a next-generation transcutaneous communication device. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Pulse Power--A Heart Physiology Program for Children.
ERIC Educational Resources Information Center
Hinson, Curt
1994-01-01
Primary grade students at a Delaware elementary school currently participate in the Pulse Power heart physiology program. Students receive mastery instruction and use heart monitors to exercise performance throughout the 6-phase program. Data from homework and from the heart monitors identify student progress, knowledge, and cardiovascular…
Lessons for Health Promotion from Selected Community-Based Heart Disease Prevention Programs.
ERIC Educational Resources Information Center
Sharma, Manoj; Galletly, Carol
1997-01-01
Discusses four key community-based coronary heart disease prevention interventions, elaborating on some of the challenges they encountered. The four interventions are the Stanford Three Community Study, Stanford Five-City Project, Minnesota Heart Health Program, and Pawtucket (Rhode Island) Heart Health Program. (SM)
Efficient physics-based tracking of heart surface motion for beating heart surgery robotic systems.
Bogatyrenko, Evgeniya; Pompey, Pascal; Hanebeck, Uwe D
2011-05-01
Tracking of beating heart motion in a robotic surgery system is required for complex cardiovascular interventions. A heart surface motion tracking method is developed, including a stochastic physics-based heart surface model and an efficient reconstruction algorithm. The algorithm uses the constraints provided by the model that exploits the physical characteristics of the heart. The main advantage of the model is that it is more realistic than most standard heart models. Additionally, no explicit matching between the measurements and the model is required. The application of meshless methods significantly reduces the complexity of physics-based tracking. Based on the stochastic physical model of the heart surface, this approach considers the motion of the intervention area and is robust to occlusions and reflections. The tracking algorithm is evaluated in simulations and experiments on an artificial heart. Providing higher accuracy than the standard model-based methods, it successfully copes with occlusions and provides high performance even when all measurements are not available. Combining the physical and stochastic description of the heart surface motion ensures physically correct and accurate prediction. Automatic initialization of the physics-based cardiac motion tracking enables system evaluation in a clinical environment.
NASA Astrophysics Data System (ADS)
Cheng, Chuyang; McGonigal, Paul R.; Schneebeli, Severin T.; Li, Hao; Vermeulen, Nicolaas A.; Ke, Chenfeng; Stoddart, J. Fraser
2015-06-01
Carrier proteins consume fuel in order to pump ions or molecules across cell membranes, creating concentration gradients. Their control over diffusion pathways, effected entirely through noncovalent bonding interactions, has inspired chemists to devise artificial systems that mimic their function. Here, we report a wholly artificial compound that acts on small molecules to create a gradient in their local concentration. It does so by using redox energy and precisely organized noncovalent bonding interactions to pump positively charged rings from solution and ensnare them around an oligomethylene chain, as part of a kinetically trapped entanglement. A redox-active viologen unit at the heart of a dumbbell-shaped molecular pump plays a dual role, first attracting and then repelling the rings during redox cycling, thereby enacting a flashing energy ratchet mechanism with a minimalistic design. Our artificial molecular pump performs work repetitively for two cycles of operation and drives rings away from equilibrium toward a higher local concentration.
Project SuperHeart: An Evaluation of a Heart Disease Intervention Program For Children.
ERIC Educational Resources Information Center
Way, Joyce W.
1981-01-01
An effective way to prevent coronary heart disease in later life is to concentrate on preventive measures in the early years before coronary heart disease becomes established. Project SuperHeart, a heart disease intervention program for young children, includes physical fitness and classroom activities emphasizing basic nutritional habits. (JN)
Application of an artificial intelligence program to therapy of high-risk surgical patients.
Patil, R S; Adibi, J; Shoemaker, W C
1996-11-01
We developed an artificial intelligence program from a large computerized database of hemodynamic and oxygen transport measurements together with prior studies defining survivors' values, outcome predictors, and a branched-chain decision tree. The artificial intelligence program was then tested on the data of 100 survivors and 100 nonsurvivors not used for the development of the program or other analyses. Using the predictor as a surrogate outcome measure, the therapy recommended by the program improved the predicted outcome 3.16% per therapeutic intervention while the actual therapy given increased outcome 1.86% in surviving patients; the artificial intelligence-recommended therapy improved outcome 7.9% in nonsurvivors, while the actual therapy given increased predicted outcome -0.29% in nonsurvivors (p < .05). There were fewer patients whose predicted outcome decreased after recommended treatment (14%) than after the actual therapy given (37%). Review of therapy recommended by the program did not reveal instances of inappropriate or potentially harmful recommendations.
Artificial intelligence in medicine: the challenges ahead.
Coiera, E W
1996-01-01
The modern study of artificial intelligence in medicine (AIM) is 25 years old. Throughout this period, the field has attracted many of the best computer scientists, and their work represents a remarkable achievement. However, AIM has not been successful-if success is judged as making an impact on the practice of medicine. Much recent work in AIM has been focused inward, addressing problems that are at the crossroads of the parent disciplines of medicine and artificial intelligence. Now, AIM must move forward with the insights that it has gained and focus on finding solutions for problems at the heart of medical practice. The growing emphasis within medicine on evidence-based practice should provide the right environment for that change. PMID:8930853
Supporting Organizational Problem Solving with a Workstation.
1982-07-01
G. [., and Sussman, G. J. AMORD: Explicit Control or Reasoning. In Proceedings of the Symposium on Artificial Intellignece and Programming Languagues...0505 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK Artificial Intelligence Laboratory AREA& WORK UNIT NUMBERS 545...extending ideas from the field of Artificial Intelligence (A), we describ office work as a problem solving activity. A knowledge embedding language called
Diabetes in the national TV news: 1971-1981.
Pichert, J W
1983-01-01
Millions of Americans get virtually all their current events information from the national nightly television news programs. The purpose of this study was to learn what diabetes-related information had been broadcast over the last 11 years by the network news programs. Another objective was to learn how that coverage compared with that given other chronic diseases. The Vanderbilt Television News Archives (VTNA) has videotaped every ABC, NBC, and CBS nightly newscast since mid-1968. The contents of each telecast have been catalogued and indexed. Indexes were searched for every segment that had anything to do with diabetes from 1971 through 1981. In the last 11 years there have been 32 diabetes-related news segments. More than a third were about the controversial attempt to ban saccharin. Because each network may carry essentially the same story, the number of nonoverlapping reports was 20. The total time of the diabetes-related segments was 70 minutes. The topics covered by the news reports included oral agents (5 reports), artificial sweeteners (12), biosynthetic human insulin (BHI) (7), and an assortment of unique items. The 32 diabetes-related segments compare with 23 about arthritis, 215 about heart diseases, and 925 dealing with cancer. A compilation of the non-overlapping segments has been shown to health professionals, who felt the stories were generally accurate. Diabetes is not portrayed as a killer. Therefore, diabetes seems less serious, and therefore less newsworthy, than heart disease or cancer.
Median Sternotomy or Right Thoracotomy Techniques for Total Artificial Heart Implantation in Calves.
Karimov, Jamshid H; Moazami, Nader; Sunagawa, Gengo; Kobayashi, Mariko; Byram, Nicole; Sale, Shiva; Such, Kimberly A; Horvath, David J; Golding, Leonard A R; Fukamachi, Kiyotaka
2016-10-01
The choice of optimal operative access technique for mechanical circulatory support device implantation ensures successful postoperative outcomes. In this study, we retrospectively evaluated the median sternotomy and lateral thoracotomy incisions for placement of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) in a bovine model. The CFTAH was implanted in 17 calves (Jersey calves; weight range, 77.0-93.9 kg) through a median sternotomy (n = 9) or right thoracotomy (n = 8) for elective chronic implantation periods of 14, 30, or 90 days. Similar preoperative preparation, surgical techniques, and postoperative care were employed. Implantation of the CFTAH was successfully performed in all cases. Both methods provided excellent surgical field visualization. After device connection, however, the median sternotomy approach provided better visualization of the anastomoses and surgical lines for hemostasis confirmation and repair due to easier device displacement, which is severely limited following right thoracotomy. All four animals sacrificed after completion of the planned durations (up to 90 days) were operated through full median sternotomy. Our data demonstrate that both approaches provide excellent initial field visualization. Full median sternotomy provides larger viewing angles at the anastomotic suture line after device connection to inflow and outflow ports. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
The American Heart Association and Heart Health Education in the Young.
ERIC Educational Resources Information Center
Tevis, Betty
1979-01-01
Several of the American Heart Association's education programs are described. The newest program is Heart Health Education in the Young, designed to stress the importance of early risk factor education. (JMF)
Alignment of human cardiomyocytes on laser patterned biphasic core/shell nanowire assemblies
NASA Astrophysics Data System (ADS)
Kiefer, Karin; Lee, Juseok; Haidar, Ayman; Martinez Miró, Marina; Akkan, Cagri Kaan; Veith, Michael; Cenk Aktas, Oral; Abdul-Khaliq, Hashim
2014-12-01
The management of end stage heart failure patients is only possible by heart transplantation or by the implantation of artificial hearts as a bridge for later transplantation. However, these therapeutic strategies are limited by a lack of donor hearts and by the associated complications, such as coagulation and infection, due to the used artificial mechanical circulatory assist devices. Therefore, new strategies for myocardial regenerative approaches are under extensive research to produce contractile myocardial tissue in the future to replace non-contractile myocardial ischemic and scarred tissue. Different approaches, such as cell transplantation, have been studied intensively. Although successful approaches have been observed, there are still limitations to the application. It is envisaged that myocardial tissue engineering can be used to help replace infarcted non-contractile tissue. The developed tissue should later mimic the aligned fibrillar structure of the extracellular matrix and provide important guidance cues for the survival, function and the needed orientation of cardiomyocytes. Nanostructured surfaces have been tested to provide a guided direction that cells can follow. In the present study, the cellular adhesion/alignment of human cardiomyocytes and the biocompatibility have been investigated after cultivation on different laser-patterned nanowires compared with unmodified nanowires. As a result, the nanostructured surfaces possessed good biocompatibility before and after laser modification. The laser-induced scalability of the pattern enabled the growth and orientation of the adhered myocardial tissue. Such approaches may be used to modify the surface of potential scaffolds to develop myocardial contractile tissue in the future.
Sauer, I M; Frank, J; Spiegelberg, A; Bücherl, E S
2000-01-01
A new electromechanical energy converting system has been developed to yield an efficient and durable orthotopic total artificial heart (TAH). The energy converter we developed transforms the unidirectional rotational motion of the motor into a longitudinal forward-reverse movement of an internal geared oval, linked directly to pusher plates on both sides. To ensure a permanent positive connection between the drive gear and the internally geared wheel, a ball bearing runs inside an oval shaped guide track. Motor, gear unit, and conical pusher plates are seated between alternately ejecting and filling ventricles. The unidirectional motion of the brushless DC motor affords easier motor control, reduces energy demand, and ensures longer life of the motor when compared with a bidirectional motion system. In vitro testing has been performed on a mock circulation loop. The overall system efficiency of the TAH Ovalis was 27-39% (mean, 36%) for the pump output range of 2-7 L/min. The maximum output of 7 L/min can be obtained with a pump rate of 130 min(-1) and an afterload pressure of 140 mm Hg. For an average sized human with a mean cardiac output of 6 L/min at a mean aortic pressure of 120 mm Hg, 5 watts of input power would be required. The size of the prototype is 560 cm3, the weight is 950 g. Our first in vitro studies demonstrated the excellent efficiency and pump performance of this new electromechanical energy converter. The results prove the feasibility of this new concept's use as an energy converter for a total artificial heart.
Feasibility of a nickel-metal hydride battery for totally implantable artificial hearts.
Okamoto, E; Yoshida, T; Fujiyoshi, M; Shimanaka, M; Takeuchi, A; Mitamura, Y; Mikami, T
1996-01-01
An implantable rechargeable battery is one of the key technologies for totally implantable artificial hearts. The nickel-metal hydride (Ni-MH) battery is promising for its high energy density of 1.5-2.0 times that of a nickel-cadmium battery. In this study, the effects of pulsatile discharge loads on the operating time and cycle life of Ni-MH batteries at 39 degrees C were studied. Two battery cells (TH-3M, 1,200 mAh, phi 14.5 x 49 mm; Toshiba, Tokyo, Japan) in series were charge/discharge cycled at 39 degrees C using a charge current of 1CA (1,200 mA) and then were fully discharged to 1.0 V/cell under either pulsatile discharge loads, which mimicked a systole (1 A for 0.3 sec) and a diastole (0.4 A for 0.3 sec), or a non pulsatile discharge load equivalent to the average of the pulsatile loads (0.7 A). Each cycle life test was interrupted on the 482nd cycle under pulsatile load, and on the 423rd cycle under non pulsatile load, because of malfunction of each battery charger. The tests showed that the pulsatile discharge cells had significantly (p < 0.001) less operating time (74.0 +/- 7.15 min) throughout the test period (up to 482 days) compared to the cells under equivalent non pulsatile discharge loads (93.7 +/- 7.74 min). The pulsatile-discharged Ni-MH cells provide significantly less operating time than the constantly discharged cells; the Ni-MH battery has an operating time of over 78 min and a cycle life of almost 500 cycles at 39 degrees C. In conclusion, the Ni-MH battery is feasible as an implantable back-up battery for a totally implantable artificial heart system.
Single-Cell Resolution of Temporal Gene Expression during Heart Development.
DeLaughter, Daniel M; Bick, Alexander G; Wakimoto, Hiroko; McKean, David; Gorham, Joshua M; Kathiriya, Irfan S; Hinson, John T; Homsy, Jason; Gray, Jesse; Pu, William; Bruneau, Benoit G; Seidman, J G; Seidman, Christine E
2016-11-21
Activation of complex molecular programs in specific cell lineages governs mammalian heart development, from a primordial linear tube to a four-chamber organ. To characterize lineage-specific, spatiotemporal developmental programs, we performed single-cell RNA sequencing of >1,200 murine cells isolated at seven time points spanning embryonic day 9.5 (primordial heart tube) to postnatal day 21 (mature heart). Using unbiased transcriptional data, we classified cardiomyocytes, endothelial cells, and fibroblast-enriched cells, thus identifying markers for temporal and chamber-specific developmental programs. By harnessing these datasets, we defined developmental ages of human and mouse pluripotent stem-cell-derived cardiomyocytes and characterized lineage-specific maturation defects in hearts of mice with heterozygous mutations in Nkx2.5 that cause human heart malformations. This spatiotemporal transcriptome analysis of heart development reveals lineage-specific gene programs underlying normal cardiac development and congenital heart disease. Copyright © 2016 Elsevier Inc. All rights reserved.
Early in vivo experience with the pediatric continuous-flow total artificial heart.
Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Kuban, Barry D; Gao, Shengqiang; Dessoffy, Raymond; Fukamachi, Kiyotaka
2018-03-30
Heart transplantation in infants and children is an accepted therapy for end-stage heart failure, but donor organ availability is low and always uncertain. Mechanical circulatory support is another standard option, but there is a lack of intracorporeal devices due to size and functional range. The purpose of this study was to evaluate the in vivo performance of our initial prototype of a pediatric continuous-flow total artificial heart (P-CFTAH), comprising a dual pump with one motor and one rotating assembly, supported by a hydrodynamic bearing. In acute studies, the P-CFTAH was implanted in 4 lambs (average weight: 28.7 ± 2.3 kg) via a median sternotomy under cardiopulmonary bypass. Pulmonary and systemic pump performance parameters were recorded. The experiments showed good anatomical fit and easy implantation, with an average aortic cross-clamp time of 98 ± 18 minutes. Baseline hemodynamics were stable in all 4 animals (pump speed: 3.4 ± 0.2 krpm; pump flow: 2.1 ± 0.9 liters/min; power: 3.0 ± 0.8 W; arterial pressure: 68 ± 10 mm Hg; left and right atrial pressures: 6 ± 1 mm Hg, for both). Any differences between left and right atrial pressures were maintained within the intended limit of ±5 mm Hg over a wide range of ratios of systemic-to-pulmonary vascular resistance (0.7 to 12), with and without pump-speed modulation. Pump-speed modulation was successfully performed to create arterial pulsation. This initial P-CFTAH prototype met the proposed requirements for self-regulation, performance, and pulse modulation. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Liu, Yang; Sanchez, Pablo G; Wei, Xufeng; Li, Tieluo; Watkins, Amelia C; Li, Shu-ying; Griffith, Bartley P; Wu, Zhongjun J
2014-01-01
Background Device availability of mechanical circulatory or respiratory support to the right heart has been limited. The purpose of this study was to investigate the effect of right heart unloading and respiratory support with a wearable integrated artificial pump-lung (APL). Methods The APL device was placed surgically between the right atrium and pulmonary artery in seven sheep. Anticoagulation was performed with heparin infusion. Its ability to unload the right ventricle (RV) was investigated by echocardiograms and right heart catheterization at different bypass flow rates. Hemodynamics and Echo data were evaluated. The device flow and gas transfer rates were also measured at different device speeds. Results Hemodynamics remained stable during APL support. There was no significant change in systemic blood pressure and cardiac index. Central venous pressure, RV pressure, RV end-diastolic dimension and RV ejection fraction were significant decreased when APL device flow rate approached 2 L/min. The linear regression showed significant correlative trends between the hemodynamic and cardiac indices and the device speed. The oxygen transfer rate increased with the device speed. The oxygen saturation from APL outlet was fully saturated (>95%) during the support. The impact of the APL support on blood elements (plasma free hemoglobin and platelet activation) was minimal. Conclusion The APL device support significantly unloaded the right ventricle with increasing device speed. The APL device provided stable hemodynamic and respiratory support in terms of blood flow and oxygen transfer. The right heart unloading performance of this wearable device need to be evaluated in the animal model with right heart failure for a long term support. PMID:24746636
Shiga, Takuya; Shiraishi, Yasuyuki; Sano, Kyosuke; Taira, Yasunori; Tsuboko, Yusuke; Yamada, Akihiro; Miura, Hidekazu; Katahira, Shintaro; Akiyama, Masatoshi; Saiki, Yoshikatsu; Yambe, Tomoyuki
2016-03-01
Implantation of a total artificial heart (TAH) is one of the therapeutic options for the treatment of patients with end-stage biventricular heart failure. There is no report on the hemodynamics of the functional centrifugal-flow TAH with functional atrial contraction (fCFTAH). We evaluated the effects of pulsatile flow by atrial contraction in acute animal models. The goats received fCFTAH that we created from two centrifugal-flow ventricular assist devices. Some hemodynamic parameters maintained acceptable levels: heart rate 115.5 ± 26.3 bpm, aortic pressure 83.5 ± 10.1 mmHg, left atrial pressure 18.0 ± 5.9 mmHg, pulmonary pressure 28.5 ± 9.7 mmHg, right atrial pressure 13.6 ± 5.2 mmHg, pump flow 4.0 ± 1.1 L/min (left) 3.9 ± 1.1 L/min (right), and cardiac index 2.13 ± 0.14 L/min/m(2). fCFTAH with atrial contraction was able to maintain the TAH circulation by forming a pulsatile flow in acute animal experiments. Taking the left and right flow rate balance using the low internal pressure loss of the VAD pumps may be easier than by other pumps having considerable internal pressure loss. We showed that the remnant atrial contraction effected the flow rate change of the centrifugal pump, and the atrial contraction waves reflected the heart rate. These results indicate that remnant atria had the possibility to preserve autonomic function in fCFTAH. We may control fCFTAH by reflecting the autonomic function, which is estimated with the flow rate change of the centrifugal pump.
Successful heart transplantation in patients with total artificial heart infections.
Taimur, Sarah; Sullivan, Timothy; Rana, Mennakshi; Patel, Gopi; Roldan, Julie; Ashley, Kimberly; Pinney, Sean; Anyanwu, Anelechi; Huprikar, Shirish
2018-02-01
Data are limited on clinical outcomes in patients awaiting heart transplant (HT) with total artificial heart (TAH) infections. We retrospectively reviewed all TAH recipients at our center. TAH infection was classified as definite if a microorganism was isolated in cultures from the exit site or deep tissues around the TAH; as probable in patients without surgical or microbiologic evidence of infection but no other explanation for persistent or recurrent bloodstream infection (BSI); or possible in patients with clinical suspicion and radiographic findings suggestive of TAH infection, but without surgical intervention or microbiologic evidence. From 2012 to 2015, a total of 13 patients received a TAH, with a median age at implantation of 52 years (range: 28-60). TAH infection occurred in nine patients (seven definite, one probable, one possible) a median of 41 days after implant (range: 17-475). The majority of TAH infections were caused by Staphylococcus species. Seven of nine patients underwent HT (four had pre-HT mediastinal washout, and five had positive HT operative cultures). Three patients had an active BSI caused by the same pathogen causing TAH infection at the time of HT, with one developing a post-HT BSI with the same bacteria. No patient developed post-HT surgical site infection caused by the TAH infection pathogen. No deaths among HT recipients were attributed to infection. TAH infection is frequently associated with BSI and mediastinitis and Staphylococcus was the most common pathogen. A multimodal approach of appropriate pre- and post-HT antimicrobial therapy, surgical drainage, and heart transplantation with radical mediastinal debridement was successful in curing infection. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Applications of Artificial Intelligence in Education--A Personal View.
ERIC Educational Resources Information Center
Richer, Mark H.
1985-01-01
Discusses: how artificial intelligence (AI) can advance education; if the future of software lies in AI; the roots of intelligent computer-assisted instruction; protocol analysis; reactive environments; LOGO programming language; student modeling and coaching; and knowledge-based instructional programs. Numerous examples of AI programs are cited.…
Epidemiology of end stage renal disease and implications for public policy.
Rubin, R J
1984-01-01
In 1972 the Congress extended Medicare coverage to all persons under age 65 suffering from end stage renal disease (ESRD). The intent of this law (PL 92-603, the Social Security Amendments of 1972) was to allow all Americans access to an emerging and very expensive technology, regardless of their ability to pay. The legislation had an immediate and dramatic impact on the population receiving dialysis. Prior to the passage of the legislation the dialysis population was white, educated, young, married, employed, and male. Within 4 years after implementation of the law, the dialysis population was more than one-third nonwhite, less well educated, significantly older, and about half female--making it more representative of the population as a whole. During consideration of this legislation the dialysis population was expected to increase from 5,000 to 7,000 patients and cost $135 million in the first year. Actually, in the first year of the program, there were 10,300 patients and the cost was $241 million. Today, while patients with ESRD represent only 0.25 percent of Medicare beneficiaries, they consume approximately 10 percent of the Medicare Part B budget. The humanitarian goals of the legislation have been met, but the costs of this program continue to rise as enrollment continues to grow. It is hoped that, through research and reimbursement policies, the per capita costs can be controlled and total costs can be reduced by shifts in treatment patterns and improvement in successful transplantation rates. There will, however, continue to be demands on our health care financing system to include reimbursement for new therapeutic modalities such as artificial hearts and heart and liver transplants.The lesson from the ESRD Program is that sound decisions require accurate epidemiologic data and cost projections.It is a challenge not easily met.
LISP on a Reduced-Instruction-Set-Processor,
1986-01-01
Digital * Press, 1984. 19. Steele, G. L. Jr., and Sussman, G.J. LAMBDA : The Ultimate Imperative. Al Memo 353, MIT, Artificial ,, Inteligence Laboratory...procedure B is No 444, MIT Artificial Intelligence Laboratory, August, recursive, if procedure A can be reexecuted before the call 1977. returns. This...the programs Artificial Intelligence Programming. Lawrence Erlbaum use apply and eval, and of these three only frl uses eval Associates, Hillsdale, New
Code of Federal Regulations, 2010 CFR
2010-01-01
... livers, beef tongues, beef hearts, and smoked meats not in casings. EC11SE91.003 For application to... on shipping containers, band labels, artificial casings, and other articles with the approval of the...
Advances in material design for regenerative medicine, drug delivery and targeting/imaging
USDA-ARS?s Scientific Manuscript database
Many of the major breakthroughs and paradigm shifts in medicine to date have occurred due to innovations and materials and/or application/implementation of materials in clinical medicine. Artificial heart valves, implantable cardiac devices, limb prosthesis, cardiovascular stents, orthopedic implan...
Biofluid mechanics--an interdisciplinary research area of the future.
Liepsch, Dieter
2006-01-01
Biofluid mechanics is a complex field that focuses on blood flow and the circulation. Clinical applications include bypass and anastomosis surgery, and the development of artificial heart valves and vessels, stents, vein and dialysis shunts. Biofluid mechanics is also involved in diagnostic and therapeutic measures, including CT and MRI, and ultrasound. The study of biofluid mechanics involves measuring blood flow, pressure, pulse wave, velocity distribution, the elasticity of the vessel wall, the flow behavior of blood to minimize complications in vessel,- neuro-, and heart surgery. Biofluid mechanics influence the lungs and circulatory system, the blood flow and micro-circulation; lymph flow, and artificial organs. Flow studies in arterial models can be done without invasive techniques on patients or animals. The results of fluid mechanic studies have shown that in the addition to basic biology, an understanding of the forces and movement on the cells is essential. Because biofluid mechanics allows for the detection of the smallest flow changes, it has an enormous potential for future cell research. Some of these will be discussed.
ALOG: A spreadsheet-based program for generating artificial logs
Matthew F. Winn; Randolph H. Wynne; Philip A. Araman
2004-01-01
Log sawing simulation computer programs can be valuable tools for training sawyers as well as for testing different sawing patterns. Most available simulation programs rely on databases from which to draw logs and can be very costly and time-consuming to develop. ALOG (Artificial LOg Generator) is a Microsoft Excel®-based computer program that was developed to...
Power consumption of rotary blood pumps: pulsatile versus constant-speed mode.
Pirbodaghi, Tohid; Cotter, Chris; Bourque, Kevin
2014-12-01
We investigated the power consumption of a HeartMate III rotary blood pump based on in vitro experiments performed in a cardiovascular simulator. To create artificial-pulse mode, we modulated the pump speed by decreasing the mean speed by 2000 rpm for 200 ms and then increasing speed by 4000 rpm (mean speeds plus 2000 rpm) for another 200 ms, creating a square waveform shape. The HeartMate III was connected to a cardiovascular simulator consisting of a hydraulic pump system to simulate left ventricle pumping action, arterial and venous compliance chambers, and an adjustable valve for peripheral resistance to facilitate the desired aortic pressure. The simulator operated based on Suga's elastance model to mimic the Starling response of the heart, thereby reproducing physiological blood flow and pressure conditions. We measured the instantaneous total electrical current and voltage of the pump to evaluate its power consumption. The aim was to answer these fundamental questions: (i) How does pump speed modulation affect pump power consumption? (ii) How does the power consumption vary in relation to external pulsatile flow? The results indicate that speed modulation and external pulsatile flow both moderately increase the power consumption. Increasing the pump speed reduces the impact of external pulsatile flow. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart
Karimov, Jamshid H.; Steffen, Robert J.; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Cruz, Vincent; Golding, Leonard A.R.; Fukamachi, Kiyotaka; Moazami, Nader
2015-01-01
Implantation of mechanical circulatory support devices is challenging, especially in patients with a small chest cavity. We evaluated how well the Cleveland Clinic continuous-flow total artificial heart (CFTAH) fit the anatomy of patients about to receive a heart transplant. A mock pump model of the CFTAH was rapid-prototyped using biocompatible materials. The model was brought to the operative table, and the direction, length, and angulation of the inflow/outflow ports and outflow conduits were evaluated after the recipient's ventricles had been resected. Thoracic cavity measurements were based on preoperative computed tomographic data. The CFTAH fit well in all five patients (height, 170 ± 9 cm; weight, 75 ± 24 kg). Body surface area was 1.9 ± 0.3 m2 (range, 1.6-2.1 m2). The required inflow and outflow port orientation of both the left and right housings appeared consistent with the current version of the CFTAH implanted in calves. The left outflow conduit remained straight, but the right outflow direction necessitated a 73 ± 22 degree angulation to prevent potential kinking when crossing over the connected left outflow. These data support the fact that our design achieves the proper anatomical relationship of the CFTAH to a patient's native vessels. PMID:25806613
Raben, Anne; Richelsen, Bjørn
2012-11-01
Artificial sweeteners can be a helpful tool to reduce energy intake and body weight and thereby risk for diabetes and cardiovascular diseases (CVD). Considering the prevailing diabesity (obesity and diabetes) epidemic, this can, therefore, be an important alternative to natural, calorie-containing sweeteners. The purpose of this review is to summarize the current evidence on the effect of artificial sweeteners on body weight, appetite, and risk markers for diabetes and CVD in humans. Short-term intervention studies have shown divergent results wrt appetite regulation, but overall artificial sweeteners cannot be claimed to affect hunger. Data from longer term intervention studies are scarce, but together they point toward a beneficial effect of artificial sweeteners on energy intake, body weight, liver fat, fasting and postprandial glycemia, insulinemia, and/or lipidemia compared with sugar. Epidemiological studies are not equivocal, but large cohort studies from the USA point toward decreased body weight and lower risk of type-2 diabetes and coronory heart diseases with increased intake of artificial sweeteners compared with sugar. Artificial sweeteners, especially in beverages, can be a useful aid to maintain reduced energy intake and body weight and decrease risk of type-2 diabetes and CVD compared with sugars. However, confirmative long-term intervention trials are still needed.
Artificial intelligence programming languages for computer aided manufacturing
NASA Technical Reports Server (NTRS)
Rieger, C.; Samet, H.; Rosenberg, J.
1979-01-01
Eight Artificial Intelligence programming languages (SAIL, LISP, MICROPLANNER, CONNIVER, MLISP, POP-2, AL, and QLISP) are presented and surveyed, with examples of their use in an automated shop environment. Control structures are compared, and distinctive features of each language are highlighted. A simple programming task is used to illustrate programs in SAIL, LISP, MICROPLANNER, and CONNIVER. The report assumes reader knowledge of programming concepts, but not necessarily of the languages surveyed.
A practical guide to exercise training for heart failure patients.
Smart, Neil; Fang, Zhi You; Marwick, Thomas H
2003-02-01
Exercise training has been shown to improve exercise capacity in patients with heart failure. We sought to examine the optimal strategy of exercise training for patients with heart failure. Review of the published data on the characteristics of the training program, with comparison of physiologic markers of exercise capacity in heart failure patients and healthy individuals and comparison of the change in these characteristics after an exercise training program. Many factors, including the duration, supervision, and venue of exercise training; the volume of working muscle; the delivery mode (eg, continuous vs. intermittent exercise), training intensity; and the concurrent effects of medical treatments may influence the results of exercise training in heart failure. Starting in an individually prescribed and safely monitored hospital-based program, followed by progression to an ongoing and progressive home program of exercise appears to be the best solution to the barriers of anxiety, adherence, and "ease of access" encountered by the heart failure patient. Various exercise training programs have been shown to improve exercise capacity and symptom status in heart failure, but these improvements may only be preserved with an ongoing maintenance program.
ENGINEERING ECONOMIC ANALYSIS OF A PROGRAM FOR ARTIFICIAL GROUNDWATER RECHARGE.
Reichard, Eric G.; Bredehoeft, John D.
1984-01-01
This study describes and demonstrates two alternate methods for evaluating the relative costs and benefits of artificial groundwater recharge using percolation ponds. The first analysis considers the benefits to be the reduction of pumping lifts and land subsidence; the second considers benefits as the alternative costs of a comparable surface delivery system. Example computations are carried out for an existing artificial recharge program in Santa Clara Valley in California. A computer groundwater model is used to estimate both the average long term and the drought period effects of artificial recharge in the study area. Results indicate that the costs of artificial recharge are considerably smaller than the alternative costs of an equivalent surface system. Refs.
Measurement and reconstruction of the leaflet geometry for a pericardial artificial heart valve.
Jiang, Hongjun; Campbell, Gord; Xi, Fengfeng
2005-03-01
This paper describes the measurement and reconstruction of the leaflet geometry for a pericardial heart valve. Tasks involved include mapping the leaflet geometries by laser digitizing and reconstructing the 3D freeform leaflet surface based on a laser scanned profile. The challenge is to design a prosthetic valve that maximizes the benefits offered to the recipient as compared to the normally operating naturally-occurring valve. This research was prompted by the fact that artificial heart valve bioprostheses do not provide long life durability comparable to the natural heart valve, together with the anticipated benefits associated with defining the valve geometries, especially the leaflet geometries for the bioprosthetic and human valves, in order to create a replicate valve fabricated from synthetic materials. Our method applies the concept of reverse engineering in order to reconstruct the freeform surface geometry. A Brown & Shape coordinate measuring machine (CMM) equipped with a HyMARC laser-digitizing system was used to measure the leaflet profiles of a Baxter Carpentier-Edwards pericardial heart valve. The computer software, Polyworks was used to pre-process the raw data obtained from the scanning, which included merging images, eliminating duplicate points, and adding interpolated points. Three methods, creating a mesh model from cloud points, creating a freeform surface from cloud points, and generating a freeform surface by B-splines are presented in this paper to reconstruct the freeform leaflet surface. The mesh model created using Polyworks can be used for rapid prototyping and visualization. To fit a freeform surface to cloud points is straightforward but the rendering of a smooth surface is usually unpredictable. A surface fitted by a group of B-splines fitted to cloud points was found to be much smoother. This method offers the possibility of manually adjusting the surface curvature, locally. However, the process is complex and requires additional manipulation. Finally, this paper presents a reverse engineered design for the pericardial heart valve which contains three identical leaflets with reconstructed geometry.
Total artificial heart in the pediatric patient with biventricular heart failure.
Park, S S; Sanders, D B; Smith, B P; Ryan, J; Plasencia, J; Osborn, M B; Wellnitz, C M; Southard, R N; Pierce, C N; Arabia, F A; Lane, J; Frakes, D; Velez, D A; Pophal, S G; Nigro, J J
2014-01-01
Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m(2), thus, limiting pediatric application of this device. This unique case report shares this pediatric institution's first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m(2)) below the recommendation of 1.7 m(2). A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would fit, as well as postoperative complications in this smaller pediatric patient.
Attitude of the Saudi community towards heart donation, transplantation, and artificial hearts.
AlHabeeb, Waleed; AlAyoubi, Fakhr; Tash, Adel; AlAhmari, Leenah; AlHabib, Khalid F
2017-07-01
To understand the attitudes of the Saudi population towards heart donation and transplantation. Methods: A survey using a questionnaire addressing attitudes towards organ transplantation and donation was conducted across 18 cities in Saudi Arabia between September 2015 and March 2016. Results: A total of 1250 respondents participated in the survey. Of these, approximately 91% agree with the concept of organ transplantation but approximately 17% do not agree with the concept of heart transplantation; 42.4% of whom reject heart transplants for religious reasons. Only 43.6% of respondents expressed a willingness to donate their heart and approximately 58% would consent to the donation of a relative's organ after death. A total of 59.7% of respondents believe that organ donation is regulated and 31.8% fear that the doctors will not try hard enough to save their lives if they consent to organ donation. Approximately 77% believe the heart is removed while the donor is alive; although, the same proportion of respondents thought they knew what brain death meant. Conclusion: In general, the Saudi population seem to accept the concept of transplantation and are willing to donate, but still hold some reservations towards heart donation.
Borneman, Tracy E.; Rose, Eli T.; Simons, Theodore R.
2014-01-01
An organism's heart rate is commonly used as an indicator of physiological stress due to environmental stimuli. We used heart rate to monitor the physiological response of American Oystercatchers (Haematopus palliatus) to human activity in their nesting environment. We placed artificial eggs with embedded microphones in 42 oystercatcher nests to record the heart rate of incubating oystercatchers continuously for up to 27 days. We used continuous video and audio recordings collected simultaneously at the nests to relate physiological response of birds (heart rate) to various types of human activity. We observed military and civilian aircraft, off-road vehicles, and pedestrians around nests. With the exception of high-speed, low-altitude military overflights, we found little evidence that oystercatcher heart rates were influenced by most types of human activity. The low-altitude flights were the only human activity to significantly increase average heart rates of incubating oystercatchers (12% above baseline). Although statistically significant, we do not consider the increase in heart rate during high-speed, low-altitude military overflights to be of biological significance. This noninvasive technique may be appropriate for other studies of stress in nesting birds.
Concurrent Programming Using Actors: Exploiting Large-Scale Parallelism,
1985-10-07
ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK* Artificial Inteligence Laboratory AREA Is WORK UNIT NUMBERS 545 Technology Square...D-R162 422 CONCURRENT PROGRMMIZNG USING f"OS XL?ITP TEH l’ LARGE-SCALE PARALLELISH(U) NASI AC E Al CAMBRIDGE ARTIFICIAL INTELLIGENCE L. G AGHA ET AL...RESOLUTION TEST CHART N~ATIONAL BUREAU OF STANDA.RDS - -96 A -E. __ _ __ __’ .,*- - -- •. - MASSACHUSETTS INSTITUTE OF TECHNOLOGY ARTIFICIAL
Manufacturing Processes: New Methods for the "Materials Age." Resources in Technology.
ERIC Educational Resources Information Center
Technology Teacher, 1990
1990-01-01
To make the best use of new materials developed for everything from computers to artificial hearts to more fuel-efficient cars, improved materials syntheses and manufacturing processes are needed. This instructional module includes teacher materials, a student quiz, and possible student outcomes. (JOW)
Disease management programs for heart failure: not just for the 'sick' heart failure population.
McDonald, Ken; Conlon, Carmel; Ledwidge, Mark
2007-02-01
The development of disease management programs has been a major advance in heart failure care, bringing about significant improvements for the heart failure population, with reduction in readmission, better use of guideline therapy and improved survival. However, at present, the majority of such programs focus their attention only on the sicker segment of this population, with little application of this important service to the broader heart failure population, where potentially benefits may be even more impressive. This has led to an imbalance in the care of patients with heart failure, where aspects of management such as regular structured review and education are preferentially given to the group at the later stages of the natural history of the syndrome. This paper argues for a far wider application of the disease management program concept in heart failure care so as to bring the benefits of specialist care, patient education and follow-up to patients at an earlier stage in the natural history of heart failure.
Archive eggs: a research and management tool for avian conservation breeding
Smith, Des H.V.; Moehrenschlager, Axel; Christensen, Nancy; Knapik, Dwight; Gibson, Keith; Converse, Sarah J.
2012-01-01
Worldwide, approximately 168 bird species are captive-bred for reintroduction into the wild. Programs tend to be initiated for species with a high level of endangerment. Depressed hatching success can be a problem for such programs and has been linked to artificial incubation. The need for artificial incubation is driven by the practice of multiclutching to increase egg production or by uncertainty over the incubation abilities of captive birds. There has been little attempt to determine how artificial incubation differs from bird-contact incubation. We describe a novel archive (data-logger) egg and use it to compare temperature, humidity, and egg-turning in 5 whooping crane (Grus americana) nests, 4 sandhill crane (G. canadensis) nests, and 3 models of artificial incubator; each of which are used to incubate eggs in whooping crane captive-breeding programs. Mean incubation temperature was 31.7° C for whooping cranes and 32.83° C for sandhill cranes. This is well below that of the artificial incubators (which were set based on a protocol of 37.6° C). Humidity in crane nests varied considerably, but median humidity in all 3 artificial incubators was substantially different from that in the crane nests. Two artificial incubators failed to turn the eggs in a way that mimicked crane egg-turning. Archive eggs are an effective tool for guiding the management of avian conservation breeding programs, and can be custom-made for other species. They also have potential to be applied to research on wild populations.
A palliative approach for heart failure end-of-life care
Maciver, Jane; Ross, Heather J.
2018-01-01
Purpose of review The current review discusses the integration of guideline and evidence-based palliative care into heart failure end-of-life (EOL) care. Recent findings North American and European heart failure societies recommend the integration of palliative care into heart failure programs. Advance care planning, shared decision-making, routine measurement of symptoms and quality of life and specialist palliative care at heart failure EOL are identified as key components to an effective heart failure palliative care program. There is limited evidence to support the effectiveness of the individual elements. However, results from the palliative care in heart failure trial suggest an integrated heart failure palliative care program can significantly improve quality of life for heart failure patients at EOL. Summary Integration of a palliative approach to heart failure EOL care helps to ensure patients receive the care that is congruent with their values, wishes and preferences. Specialist palliative care referrals are limited to those who are truly at heart failure EOL. PMID:29135524
Fluid mechanics of heart valves.
Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S
2004-01-01
Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.
Simulation of Blood flow in Different Configurations Design of Bi-leaflet Mechanical Heart Valve
NASA Astrophysics Data System (ADS)
Hafizah Mokhtar, N.; Abas, Aizat
2018-05-01
In this work, two different designs of artificial heart valve were devised and then compared by considering the thrombosis, wear and valve orifice to anatomical orifice ratio of each mechanical heart valve. These different design configurations of bi-leaflet mechanical heart valves model are created through the use of Computer-aided design (CAD) modelling and simulated using Computational fluid dynamic (CFD) software. Design 1 is based on existing conventional bi-leaflet valve and design 2 based on modified bi-leaflet respectively. The flow pattern, velocity, vorticity and stress analysis have been done to justify the best design. Based on results, both of the designs show a Doppler velocity index of less than the allowable standard of 2.2 which is safe to be used as replacement of the human heart valve. However, design 2 shows that it has a lower possibility of cavitation issue which will lead to lower thrombosis and provide good central flow area of blood as compared to design 1.
Fuzzy Expert System for Heart Attack Diagnosis
NASA Astrophysics Data System (ADS)
Hassan, Norlida; Arbaiy, Nureize; Shah, Noor Aziyan Ahmad; Afizah Afif@Afip, Zehan
2017-08-01
Heart attack is one of the serious illnesses and reported as the main killer disease. Early prevention is significant to reduce the risk of having the disease. The prevention efforts can be strengthen through awareness and education about risk factor and healthy lifestyle. Therefore the knowledge dissemination is needed to play role in order to distribute and educate public in health care management and disease prevention. Since the knowledge dissemination in medical is important, there is a need to develop a knowledge based system that can emulate human intelligence to assist decision making process. Thereby, this study utilized hybrid artificial intelligence (AI) techniques to develop a Fuzzy Expert System for Diagnosing Heart Attack Disease (HAD). This system integrates fuzzy logic with expert system, which helps the medical practitioner and people to predict the risk and as well as diagnosing heart attack based on given symptom. The development of HAD is expected not only providing expert knowledge but potentially become one of learning resources to help citizens to develop awareness about heart-healthy lifestyle.
Development and Evaluation of Heartbeat: A Machine Perfusion Heart Preservation System.
Li, Yongnan; Zeng, Qingdong; Liu, Gang; Du, Junzhe; Gao, Bingren; Wang, Wei; Zheng, Zhe; Hu, Shengshou; Ji, Bingyang
2017-11-01
Static cold storage is accompanied with a partial safe ischemic interval for donor hearts. In this current study, a machine perfusion system was built to provide a better preservation for the donor heart and assessment for myocardial function. Chinese mini-swine (weight 30-35 kg, n = 16) were randomly divided into HTK, Celsior, and Heartbeat groups. All donor hearts were respectively preserved for 8 hours under static cold storage or machine perfusion. The perfusion solution is aimed to maintain its homeostasis based on monitoring the Heartbeat group. The ultrastructure of myocardium suggests better myocardial protection in the Heartbeat group compared with HTK or Celsior-preserved hearts. The myocardial and coronary artery structural and functional integrity was evaluated by immunofluorescence and Western blots in the Heartbeat. In the Heartbeat group, donor hearts maintained a high adenosine triphosphate level. Bcl-2 and Beclin-1 protein demonstrates high expression in the Celsior group. The Heartbeat system can be used to preserve donor hearts, and it could guarantee the myocardial and endothelial function of hearts during machine perfusion. Translating Heartbeat into clinical practice, it is such as to impact on donor heart preservation for cardiac transplantation. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Suzuki, T; Okamura, K; Kimura, Y; Watanabe, T; Yaegashi, N; Murotsuki, J; Uehara, S; Yajima, A
2000-05-01
The appearance of the sinusoidal heart rate pattern found on fetal cardiotocograms has not been fully explained, either physiologically or clinically. In this study we performed power spectral analysis on the sinusoidal heart rate pattern obtained by administration of arginine vasopressin and atropine sulfate to investigate its frequency components in fetal lambs with long-term instrument implantation. Eleven tests were performed in 4 fetal lambs at 120 to 130 days' gestation. An artificial sinusoidal heart rate pattern was obtained by administration of atropine sulfate and arginine vasopressin in 9 tests. An autoregression model was used to compare the spectral patterns before and during the sinusoidal heart rate pattern. Marked decreases in low-frequency (0.025-0.125 cycles/beat) and high-frequency (0.2-0.5 cycles/beat) areas were observed in the presence of the sinusoidal heart rate pattern. However, there were no significant changes in the very-low-frequency area (0.01-0.025 cycles/beat), which corresponds to the frequency of the sinusoidal heart rate pattern. The sinusoidal heart rate pattern may represent a very low-frequency component inherent in fetal heart rate variability that appears when low- and high-frequency components are reduced as a result of strongly suppressed autonomic nervous activity.
A Nonrandomized Evaluation of a Brief Nurtured Heart Approach Parent Training Program
ERIC Educational Resources Information Center
Brennan, Alison L.; Hektner, Joel M.; Brotherson, Sean E.; Hansen, Tracy M.
2016-01-01
Background: Parent training programs are increasingly being offered to the general public with little formal evaluation of their effects. One such program, the Nurtured Heart Approach to parenting (NHA; Glasser and Easley in "Transforming the difficult child: The Nurtured Heart Approach," Vaughan Printing, Nashville, 2008), contains…
Schmidt, Thomas; Bjarnason-Wehrens, Birna; Bartsch, Petra; Deniz, Ezin; Schmitto, Jan; Schulte-Eistrup, Sebastian; Willemsen, Detlev; Reiss, Nils
2018-01-01
Adequate physical and functional performance is an important prerequisite for renewed participation and integration in self-determined private and (where appropriate) professional lives following left ventricular assist device (LVAD) implantation. During cardiac rehabilitation (CR), individually adapted exercise programs aim to increase exercise capacity and functional performance. A retrospective analysis of cardiopulmonary exercise capacity and functional performance in LVAD patients at discharge from a cardiac rehabilitation program was conducted. The results from 68 LVAD patients (59 males, 9 females; 55.9 ± 11.7 years; 47 HVAD, 2 MVAD, 15 HeartMate II, 4 HeartMate 3, and 4 different implanting centers) were included in the analysis. Exercise capacity was assessed using a cardiopulmonary exercise test on a bicycle ergometer (ramp protocol; 10 W/min). The 6-min walk test was used to determine functional performance. At discharge from CR (53 ± 17 days after implantation), the mean peak work load achieved was 62.2 ± 19.3 W (38% of predicted values) or 0.79 ± 0.25 W/kg body weight. The mean cardiopulmonary exercise capacity (relative peak oxygen uptake) was 10.6 ± 5.3 mL/kg/min (37% of predicted values). The 6-min walk distance improved significantly during CR (325 ± 106 to 405 ± 77 m; P < 0.01). No adverse events were documented during CR. The results show that, even following LVAD implantation, cardiopulmonary exercise capacity remains considerably restricted. In contrast, functional performance, measured by the 6-min walk distance, reaches an acceptable level. Light everyday tasks seem to be realistically surmountable for patients, making discharge from inpatient rehabilitation possible. Long-term monitoring is required in order to evaluate the situation and how it develops further. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Artificial gait in complete spinal cord injured subjects: how to assess clinical performance.
Pithon, Karla Rocha; Abreu, Daniela Cristina Carvalho de; Vasconcelos-Neto, Renata; Martins, Luiz Eduardo Barreto; Cliquet, Alberto
2015-02-01
Adapt the 6 minutes walking test (6MWT) to artificial gait in complete spinal cord injured (SCI) patients aided by neuromuscular electrical stimulation. Nine male individuals with paraplegia (AIS A) participated in this study. Lesion levels varied between T4 and T12 and time post injured from 4 to 13 years. Patients performed 6MWT 1 and 6MWT 2. They used neuromuscular electrical stimulation, and were aided by a walker. The differences between two 6MWT were assessed by using a paired t test. Multiple r-squared was also calculated. The 6MWT 1 and 6MWT 2 were not statistically different for heart rate, distance, mean speed and blood pressure. Multiple r-squared (r2 = 0.96) explained 96% of the variation in the distance walked. The use of 6MWT in artificial gait towards assessing exercise walking capacity is reproducible and easy to apply. It can be used to assess SCI artificial gait clinical performance.
Thermally induced magnetic relaxation in square artificial spin ice.
Andersson, M S; Pappas, S D; Stopfel, H; Östman, E; Stein, A; Nordblad, P; Mathieu, R; Hjörvarsson, B; Kapaklis, V
2016-11-24
The properties of natural and artificial assemblies of interacting elements, ranging from Quarks to Galaxies, are at the heart of Physics. The collective response and dynamics of such assemblies are dictated by the intrinsic dynamical properties of the building blocks, the nature of their interactions and topological constraints. Here we report on the relaxation dynamics of the magnetization of artificial assemblies of mesoscopic spins. In our model nano-magnetic system - square artificial spin ice - we are able to control the geometrical arrangement and interaction strength between the magnetically interacting building blocks by means of nano-lithography. Using time resolved magnetometry we show that the relaxation process can be described using the Kohlrausch law and that the extracted temperature dependent relaxation times of the assemblies follow the Vogel-Fulcher law. The results provide insight into the relaxation dynamics of mesoscopic nano-magnetic model systems, with adjustable energy and time scales, and demonstrates that these can serve as an ideal playground for the studies of collective dynamics and relaxations.
Thermally induced magnetic relaxation in square artificial spin ice
NASA Astrophysics Data System (ADS)
Andersson, M. S.; Pappas, S. D.; Stopfel, H.; Östman, E.; Stein, A.; Nordblad, P.; Mathieu, R.; Hjörvarsson, B.; Kapaklis, V.
2016-11-01
The properties of natural and artificial assemblies of interacting elements, ranging from Quarks to Galaxies, are at the heart of Physics. The collective response and dynamics of such assemblies are dictated by the intrinsic dynamical properties of the building blocks, the nature of their interactions and topological constraints. Here we report on the relaxation dynamics of the magnetization of artificial assemblies of mesoscopic spins. In our model nano-magnetic system - square artificial spin ice - we are able to control the geometrical arrangement and interaction strength between the magnetically interacting building blocks by means of nano-lithography. Using time resolved magnetometry we show that the relaxation process can be described using the Kohlrausch law and that the extracted temperature dependent relaxation times of the assemblies follow the Vogel-Fulcher law. The results provide insight into the relaxation dynamics of mesoscopic nano-magnetic model systems, with adjustable energy and time scales, and demonstrates that these can serve as an ideal playground for the studies of collective dynamics and relaxations.
ERIC Educational Resources Information Center
Ross, Margaret E.
1988-01-01
Describes the experiences of one instructor in designing and implementing a short course in scientific French for upper level students majoring in applied biology at Glasgow College. Materials used and aspects of scientific language chosen are briefly discussed. (LMO)
Cardiac and Vascular Function in Bedrested Volunteers: Effects of Artificial Gravity Training
NASA Technical Reports Server (NTRS)
Meng, M.; Platts, S.; Stenger, M.; Diedrich, A.; Schlegel, T.; Natapoff, A.; Knapp, C.; Evans, J.
2007-01-01
Cardiovascular effects of an artificial gravity (AG) countermeasure on deconditioned male volunteers were studied. In two groups of men we measured cardiovascular parameters at rest and in response to 30 minutes of 80 deg. head up tilt (HUT) before, at the end of, and four days following 21 days of 6 deg. head down bed rest (HDBR). One group (N=7) underwent no countermeasure while the other (N=8) received a daily, one hour, dose (2.5 gz at the foot, decreasing to 1.0 gz at the heart) of AG training on the Johnson Space Center short radius centrifuge. Cardiovascular parameters measured included heart rate, blood pressure, stroke volume, cardiac output, peripheral vascular resistance, plasma volume shifts, and vasoactive hormones. Untrained subjects exhibited shorter tilt survival (on average 8 minutes shorter) compared to trained subjects. By the end of bed rest, mean heart rate (MHR) was elevated in both groups (both supine and during tilt). In addition, treated subjects demonstrated lower, tilt-induced, increases in MHR four days following HDBR, indicating a more rapid return to pre bed rest conditions. Results from an index of autonomic balance (percentage of MHR spectral power in the respiratory frequency range) in control of heart rate are consistent with the interpretation that parasympathetic nervous system withdrawal was responsible for both tilt- and bed rest-induced increases in MHR. Our data support our pre-study hypothesis that AG treatment would lessen cardiovascular effects of deconditioning in bed rested men and suggest that AG should be further pursued as a space flight countermeasure.
76 FR 57066 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-15
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Heart, Lung, and..., discussion, and evaluation of individual intramural programs and projects conducted by the National Heart... Assistance Program Nos. 93.233, National Center for Sleep Disorders Research; 93.837, Heart and Vascular...
77 FR 58402 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Heart, Lung, and..., discussion, and evaluation of individual intramural programs and projects conducted by the National Heart... Assistance Program Nos. 93.233, National Center for Sleep Disorders Research; 93.837, Heart and Vascular...
Nevalainen, T J; Gavin, J B; Seelye, R N; Whitehouse, S; Donnell, M
1978-07-01
The effect of normal and artificially induced rigor mortis on the vascular passage of erythrocytes and fluid through isolated dog hearts was studied. Increased rigidity of 6-mm thick transmural sections through the centre of the posterior papillary muscle was used as an indication of rigor. The perfusibility of the myocardium was tested by injecting 10 ml of 1% sodium fluorescein in Hanks solution into the circumflex branch of the left coronary artery. In prerigor hearts (20 minute incubation) fluorescein perfused the myocardium evenly whether or not it was preceded by an injection of 10 ml of heparinized dog blood. Rigor mortis developed in all hearts after 90 minutes incubation or within 20 minutes of perfusing the heart with 50 ml of 5 mM iodoacetate in Hanks solution. Fluorescein injected into hearts in rigor did not enter the posterior papillary muscle and adjacent subendocardium whether or not it was preceded by heparinized blood. Thus the vascular occlusion caused by rigor in the dog heart appears to be so effective that it prevents flow into the subendocardium of small soluble ions such as fluorescein.
A Primer for Problem Solving Using Artificial Intelligence.
ERIC Educational Resources Information Center
Schell, George P.
1988-01-01
Reviews the development of artificial intelligence systems and the mechanisms used, including knowledge representation, programing languages, and problem processing systems. Eleven books and 6 journals are listed as sources of information on artificial intelligence. (23 references) (CLB)
Inspection Methods in Programming: Cliches and Plans.
1987-12-01
PROGRAM ELEMENT. PROJECT. TASK Artificial Inteligence Laboratory AREA & WORK UN IT NUMBERS J 545 Technology Square Cambridge, MA 02139 $L. CONTROLLING...U) MASSACHUSETTS INST OF TECH CAMBRIDGE ARTIFICIAL INTELLIGENCE LAB C RICH DEC 87 AI-M-±05 UNCLASSIFIED NW014-B5-K-0124 F/G 12/5 NL ’lllll l l l...S %P W. J % % %s MASSACHUSETTS INSTITUTE OF TECHNOLOGY N ARTIFICIAL INTELLIGENCE LABORATORY 00 A.I. Memo No. 1005 December 1987 N Inspection Methods
1974-07-01
iiWU -immmemmmmm This document was generated by the Stanford Artificial Intelligence Laboratory’s document compiler, "PUB" and reproducec’ on a...for more sophisticated artificial (programming) languages. The new issues became those of how to represent a grammar as precise syntactic structures...challenge lies in discovering - either by synthesis of an artificial system, or by analysis of a natural one - the underlying logical (a. opposed to
ERIC Educational Resources Information Center
Gans, Kim M.; And Others
1994-01-01
Examines the development and implementation of the Pawtucket Heart Health Program (PHHP), a community research and demonstration project in Pawtucket (Rhode Island) focusing on PHHP's school intervention project, designed to help decrease the prevalence of cardiovascular disease risk factors among the students and staff of Pawtucket schools. (MDM)
Heart Rates of Elementary Physical Education Students during the Dancing Classrooms Program
ERIC Educational Resources Information Center
Nelson, Larry; Evans, Melissa; Guess, Wendy; Morris, Mary; Olson, Terry; Buckwalter, John
2011-01-01
We examined how different types of dance activities, along with their duration, influenced heart rate responses among fifth-grade physical education students (N = 96) who participated in the Dancing Classrooms program. Results indicated that the overall Dancing Classrooms program elicits a moderate cardiovascular heart rate response (M = 124.4…
Reed, Shelby D; Neilson, Matthew P; Gardner, Matthew; Li, Yanhong; Briggs, Andrew H; Polsky, Daniel E; Graham, Felicia L; Bowers, Margaret T; Paul, Sara C; Granger, Bradi B; Schulman, Kevin A; Whellan, David J; Riegel, Barbara; Levy, Wayne C
2015-11-01
Heart failure disease management programs can influence medical resource use and quality-adjusted survival. Because projecting long-term costs and survival is challenging, a consistent and valid approach to extrapolating short-term outcomes would be valuable. We developed the Tools for Economic Analysis of Patient Management Interventions in Heart Failure Cost-Effectiveness Model, a Web-based simulation tool designed to integrate data on demographic, clinical, and laboratory characteristics; use of evidence-based medications; and costs to generate predicted outcomes. Survival projections are based on a modified Seattle Heart Failure Model. Projections of resource use and quality of life are modeled using relationships with time-varying Seattle Heart Failure Model scores. The model can be used to evaluate parallel-group and single-cohort study designs and hypothetical programs. Simulations consist of 10,000 pairs of virtual cohorts used to generate estimates of resource use, costs, survival, and incremental cost-effectiveness ratios from user inputs. The model demonstrated acceptable internal and external validity in replicating resource use, costs, and survival estimates from 3 clinical trials. Simulations to evaluate the cost-effectiveness of heart failure disease management programs across 3 scenarios demonstrate how the model can be used to design a program in which short-term improvements in functioning and use of evidence-based treatments are sufficient to demonstrate good long-term value to the health care system. The Tools for Economic Analysis of Patient Management Interventions in Heart Failure Cost-Effectiveness Model provides researchers and providers with a tool for conducting long-term cost-effectiveness analyses of disease management programs in heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.
Transitional care programs improve outcomes for heart failure patients: an integrative review.
Stamp, Kelly D; Machado, Monique A; Allen, Nancy A
2014-01-01
Individuals with heart failure are frequently rehospitalized owing to a lack of knowledge concerning how to perform their self-care and when to inform their healthcare provider of worsening symptoms. Because there are an overwhelming number of hospital readmissions for individuals with heart failure, efforts are underway to discover how they can be supported and educated during their hospitalization and subsequently followed by a nurse after discharge for continued education and support. The purpose of this integrative review was to critically examine the interventions, quality of life, and readmission rates of individuals with heart failure who are enrolled in a transitional care program. The second aim was to examine the cost-effectiveness of nurse-led transitional care programs. The results of this integrative review (n = 20) showed that transitional care programs for individuals with heart failure can increase a patient's quality of life and decrease the number of readmissions and the overall cost of care. The types of interventions that were most successful in decreasing readmissions used home visits alone or in combination with telephone calls. There is a need for nurse researchers to address gaps in transitional care for heart failure patients by performing studies with larger randomized clinical trials and measuring outcomes such as readmissions at regular intervals over the study period. The Patient Protection and Affordable Care Act will change reimbursement for heart failure readmissions and presents opportunities for healthcare teams to build transitional care programs for patients with conditions such as heart failure. This integrative review can be used to determine effective intervention strategies for transitional care programs and highlights the gaps in research. Healthcare teams that use these programs within their practice may increase continuity of care and quality of life and decrease readmissions and healthcare costs for individuals with heart failure.
Arslanian-Engoren, Cynthia; Eastwood, Jo-Ann; De Jong, Marla J; Berra, Kathy
2015-01-01
The American Heart Association created Go Red Heart Match, a free and secure online program that enables women to connect with each other to fight heart disease either personally or as a caregiver for someone with heart disease. Through these connections, participants have an opportunity to develop a personal, private, and supportive relationship with other women; share common experiences; and motivate and encourage each other to follow a heart-healthy lifestyle. The aims of this study were to describe the demographic characteristics of the Go Red Heart Match responders and to determine whether participation in the program prompted participants to engage in heart-healthy behaviors. A secondary analysis of data collected as part of a needs assessment survey from the American Heart Association Go Red Heart Match was conducted. A total of 117 (35%) of the 334 invited women completed the survey. Most responders were female, married, and college educated. A total of 105 (90%) responders were diagnosed with a type of heart disease or stroke and 77 (73%) responders had undergone treatment. As a result of participating in the program, 75% of the responders reported the following improvements in heart-healthy behaviors: eating a more heart-healthy diet (54%), exercising more frequently (53%), losing weight (47%), and quitting smoking (10%). Responders who had a diagnosis of heart attack (n = 48) were more likely (P = .003) to quit smoking than were those with other diagnoses (n = 69). Notably, 48% of responders reported encouraging someone else in their life to speak to their doctor about their risk for heart disease. Most women who participated in Heart Match reported engaging in new heart-healthy behaviors. The findings support expanding the existing program in a more diverse population as a potentially important way to reach women and encourage cardiovascular disease risk reduction for those with heart disease and stroke.
Miessau, J; Yang, Q; Unai, S; Entwistle, J W C; Cavarocchi, N C; Hirose, H
2015-07-01
We report a unique utilization of a double-lumen, bi-caval Avalon cannula for veno-venous (VV) extracorporeal membrane oxygenation (ECMO) during placement of a total artificial heart (TAH, SynCardia, Tucson, AZ). A 22-year-old female with post-partum cardiomyopathy was rescued on veno-arterial (VA) ECMO because of cardiogenic shock. The inability to wean ECMO necessitated implantation of the TAH as a bridge to transplant. In addition, the patient continued to have respiratory failure and concomitant VV ECMO was planned with the implant. During TAH implantation, the Avalon cannula was placed percutaneously from the right internal jugular vein into the inferior vena cava (IVC) under direct vision while the right atrium was open. During VV ECMO support, adequate flows on both ECMO and TAH were maintained without adverse events. VV ECMO was discontinued, without reopening the chest, once the patient's respiratory failure improved. However, the patient subsequently developed a profound respiratory acidosis and required VV ECMO for CO2 removal. The Avalon cannula was placed in the femoral vein to avoid accessing the internal jugular vein and risking damage to the TAH. The patient's oxygenation eventually improved and the cannula was removed at the bedside. The patient was supported for 22 days on VV ECMO and successfully weaned from the ventilator prior to her orthotropic heart transplantation. © The Author(s) 2014.
Braunsdorf, Sandy
2017-07-01
Background: The growing number of mechanical circulatory support systems implanted with successful results in terms of quality of life and physical resilience means that more and more people are being discharged from hospital to live at home with an artificial heart. This puts high requirements on affected persons’ disease and therapy management – a subject which has attracted very little qualitative research to date. Aim: This study therefore sought to shed light on how people with mechanical circulatory support experience their everyday lives. The aim was to document the subjective associations of those affected from an insider perspective. Methods: Following the interpretative phenomenological paradigm, narrative interviews were conducted with two female and eight male participants. For qualitative analysis, a multi-step process guided by the methodology of hermeneutic philosophy was used. Results: The qualitative data analysis revealed five main topic areas. These describe patients’ state of health after implantation and the various adjustments, constraints and pressures necessitated by their illness and therapeutic requirements. On this basis, coping and management strategies are identified. Other significant aspects of patients’ everyday lives are social interaction and environment and health care with an artificial heart. Conclusions: The findings add to our knowledge of the day-to-day lives of people with mechanical circulatory support systems, giving us a better understanding of their specific situation.
Ahn, J M; Lee, J H; Choi, S W; Kim, W E; Omn, K S; Park, S K; Kim, W G; Roh, J R; Min, B G
1998-03-01
The moving actuator type total artificial heart (TAH) developed in the Seoul National University has numerous design improvements based upon the digital signal processor (DSP). These improvements include the implantability of all electronics, an automatic control algorithm, and extension of the battery run-time in connection with an amorphous silicon solar system (SS). The implantable electronics consist of the motor drive, main processor, intelligent Li ion battery management (LIBM) based upon the DSP, telemetry system, and transcutaneous energy transmission (TET) system. Major changes in the implantable electronics include decreasing the temperature rise by over 21 degrees C on the motor drive, volume reduction (40 x 55 x 33 mm, 7 cell assembly) of the battery pack using a Li ion (3.6 V/cell, 900 mA.h), and improvement of the battery run-time (over 40 min) while providing the cardiac output (CO) of 5 L/min at 100 mm Hg afterload when the external battery for testing is connected with the SS (2.5 W, 192.192, 1 kg) for the external battery recharge or the partial TAH drive. The phase locked loop (PLL) based telemetry system was implemented to improve stability and the error correction DSP algorithm programmed to achieve high accuracy. A field focused light emitting diode (LED) was used to obtain low light scattering along the propagation path, similar to the optical property of the laser and miniature sized, mounted on the pancake type TET coils. The TET operating resonance frequency was self tuned in a range of 360 to 410 kHz to provide enough power even at high afterloads. An automatic cardiac output regulation algorithm was developed based on interventricular pressure analysis and carried out in several animal experiments successfully. All electronics have been evaluated in vitro and in vivo and prepared for implantation of the TAH. Substantial progress has been made in designing a completely implantable TAH at the preclinical stage.
Artificial Intelligence in ADA: Pattern-Directed Processing. Final Report.
ERIC Educational Resources Information Center
Reeker, Larry H.; And Others
To demonstrate to computer programmers that the programming language Ada provides superior facilities for use in artificial intelligence applications, the three papers included in this report investigate the capabilities that exist within Ada for "pattern-directed" programming. The first paper (Larry H. Reeker, Tulane University) is…
Artificial Intelligence: Applications in Education.
ERIC Educational Resources Information Center
Thorkildsen, Ron J.; And Others
1986-01-01
Artificial intelligence techniques are used in computer programs to search out rapidly and retrieve information from very large databases. Programing advances have also led to the development of systems that provide expert consultation (expert systems). These systems, as applied to education, are the primary emphasis of this article. (LMO)
Artificial intelligence in astronomy - a forecast.
NASA Astrophysics Data System (ADS)
Adorf, H. M.
Since several years artificial intelligence techniques are being actively used in astronomy, particularly within the Hubble Space Telescope project. This contribution reviews achievements, analyses some problems of using artificial intelligence in an astronomical environment, and projects current AI programming trends into the future.
ERIC Educational Resources Information Center
Abelson, Harold; diSessa, Andy
During the summer of 1976, the MIT Artificial Intelligence Laboratory sponsored a Student Science Training Program in Mathematics, Physics, and Computer Science for high ability secondary school students. This report describes, in some detail, the style of the program, the curriculum and the projects the students under-took. It is hoped that this…
McClure, Michelle M; Utter, Fred M; Baldwin, Casey; Carmichael, Richard W; Hassemer, Peter F; Howell, Philip J; Spruell, Paul; Cooney, Thomas D; Schaller, Howard A; Petrosky, Charles E
2008-01-01
Most hatchery programs for anadromous salmonids have been initiated to increase the numbers of fish for harvest, to mitigate for habitat losses, or to increase abundance in populations at low abundance. However, the manner in which these programs are implemented can have significant impacts on the evolutionary trajectory and long-term viability of populations. In this paper, we review the potential benefits and risks of hatchery programs relative to the conservation of species listed under the US Endangered Species Act. To illustrate, we present the range of potential effects within a population as well as among populations of Chinook salmon (Oncorhynchus tshawytscha) where changes to major hatchery programs are being considered. We apply evolutionary considerations emerging from these examples to suggest broader principles for hatchery uses that are consistent with conservation goals. We conclude that because of the evolutionary risks posed by artificial propagation programs, they should not be viewed as a substitute for addressing other limiting factors that prevent achieving viability. At the population level, artificial propagation programs that are implemented as a short-term approach to avoid imminent extinction are more likely to achieve long-term population viability than approaches that rely on long-term supplementation. In addition, artificial propagation programs can have out-of-population impacts that should be considered in conservation planning. PMID:25567637
Category Induction via Distributional Analysis: Evidence from a Serial Reaction Time Task
ERIC Educational Resources Information Center
Hunt, Ruskin H.; Aslin, Richard N.
2010-01-01
Category formation lies at the heart of a number of higher-order behaviors, including language. We assessed the ability of human adults to learn, from distributional information alone, categories embedded in a sequence of input stimuli using a serial reaction time task. Artificial grammars generated corpora of input strings containing a…
Capturing Problem-Solving Processes Using Critical Rationalism
ERIC Educational Resources Information Center
Chitpin, Stephanie; Simon, Marielle
2012-01-01
The examination of problem-solving processes continues to be a current research topic in education. Knowing how to solve problems is not only a key aspect of learning mathematics but is also at the heart of cognitive theories, linguistics, artificial intelligence, and computers sciences. Problem solving is a multistep, higher-order cognitive task…
THRESHOLD LOGIC IN ARTIFICIAL INTELLIGENCE
COMPUTER LOGIC, ARTIFICIAL INTELLIGENCE , BIONICS, GEOMETRY, INPUT OUTPUT DEVICES, LINEAR PROGRAMMING, MATHEMATICAL LOGIC, MATHEMATICAL PREDICTION, NETWORKS, PATTERN RECOGNITION, PROBABILITY, SWITCHING CIRCUITS, SYNTHESIS
Fukamachi, Kiyotaka; Karimov, Jamshid H; Sunagawa, Gengo; Horvath, David J; Byram, Nicole; Kuban, Barry D; Dessoffy, Raymond; Sale, Shiva; Golding, Leonard A R; Moazami, Nader
2017-12-01
The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) on hemodynamics and pump flow in an awake chronic calf model. The sinusoidal pump speed modulations, performed on the day of elective sacrifice, were set at ±15 and ± 25% of mean pump speed at 80 bpm in four awake calves with a CFTAH. The systemic and pulmonary arterial pulse pressures increased to 12.0 and 12.3 mmHg (±15% modulation) and to 15.9 and 15.7 mmHg (±25% modulation), respectively. The pulsatility index and surplus hemodynamic energy significantly increased, respectively, to 1.05 and 1346 ergs/cm at ±15% speed modulation and to 1.51 and 3381 ergs/cm at ±25% speed modulation. This study showed that it is feasible to generate pressure pulsatility with pump speed modulation; the platform is suitable for evaluating the physiologic impact of pulsatility and allows determination of the best speed modulations in terms of magnitude, frequency, and profiles.
Artificial Intelligence--Applications in Education.
ERIC Educational Resources Information Center
Poirot, James L.; Norris, Cathleen A.
1987-01-01
This first in a projected series of five articles discusses artificial intelligence and its impact on education. Highlights include the history of artificial intelligence and the impact of microcomputers; learning processes; human factors and interfaces; computer assisted instruction and intelligent tutoring systems; logic programing; and expert…
The Syncardia™ total artificial heart: in vivo, in vitro, and computational modeling studies
Slepian, Marvin J.; Alemu, Yared; Soares, João Silva; Smith, Richard G.; Einav, Shmuel; Bluestein, Danny
2014-01-01
The SynCardia™ total artificial heart (TAH) is the only FDA-approved TAH in the world. The SynCardia™ TAH is a pneumatically driven, pulsatile system capable of flows of >9 L/min. The TAH is indicated for use as a bridge to transplantation (BTT) in patients at imminent risk of death from non-reversible bi-ventricular failure. In the Pivotal US approval trial the TAH achieved a BTT rate of >79%. Recently a multi-center, post-market approval study similarly demonstrated a comparable BTT rate. A major milestone was recently achieved for the TAH, with over 1100 TAHs having been implanted to date, with the bulk of implantation occurring at an ever increasing rate in the past few years. The TAH is most commonly utilized to save the lives of patients dying from end-stage bi-ventricular heart failure associated with ischemic or non-ischemic dilated cardiomyopathy. Beyond progressive chronic heart failure, the TAH has demonstrated great efficacy in supporting patients with acute irreversible heart failure associated with massive acute myocardial infarction. In recent years several diverse clinical scenarios have also proven to be well served by the TAH including severe heart failure associated with advanced congenital heart disease. failed or burned-out transplants, infiltrative and restrictive cardiomyopathies and failed ventricular assist devices. Looking to the future a major unmet need remains in providing total heart support for children and small adults. As such, the present TAH design must be scaled to fit the smaller patient, while providing equivalent, if not superior flow characteristics, shear profiles and overall device thrombogenicity. To aid in the development of a new “pediatric,” TAH an engineering methodology known as “Device Thrombogenicity Emulation (DTE)”, that we have recently developed and described, is being employed. Recently, to further our engineering understanding of the TAH, as steps towards next generation designs we have: (1) assessed of the degree of platelet reactivity induced by the present clinical 70 cc TAH using a closed loop platelet activity state assay, (2) modeled the motion of the TAH pulsatile mobile diaphragm, and (3) performed fluid-structure interactions and assessment of the flow behavior through inflow and outflow regions of the TAH fitted with modern bi-leaflet heart valves. Developing a range of TAH devices will afford biventricular replacement therapy to a wide range of patients, for both short and long-term therapy. PMID:23305813
An Approach to Object Recognition: Aligning Pictorial Descriptions.
1986-12-01
PERFORMING 0RGANIZATION NAMIE ANDORS IS551. PROGRAM ELEMENT. PROJECT. TASK Artificial Inteligence Laboratory AREKA A WORK UNIT NUMBERS ( 545 Technology... ARTIFICIAL INTELLIGENCE LABORATORY A.I. Memo No. 931 December, 1986 AN APPROACH TO OBJECT RECOGNITION: ALIGNING PICTORIAL DESCRIPTIONS Shimon Ullman...within the Artificial Intelligence Laboratory at the Massachusetts Institute of Technology. Support for the A.I. Laboratory’s artificial intelligence
Robert G. Hooper; William E. Taylor; Susan C. Loeb
2004-01-01
Between 1990 and 1992 an extensive artificial cavity installation program was conducted on the Francis Marion National Forest (FMNF) in coastal South Carolina where Hurricane Hugo had caused vast devastation. Four artificial cavity types were installed: drilled starts, drilled cavities, modified drilled cavities, and inserts. In 1998, we examined 443 of the artificial...
DeWalt, Darren A; Pignone, Michael; Malone, Robb; Rawls, Cathy; Kosnar, Margaret C; George, Geeta; Bryant, Betsy; Rothman, Russell L; Angel, Bonnie
2004-10-01
Development and pilot testing of a disease management program for low literacy patients with heart failure. Randomized trials have shown that disease management programs can reduce hospitalizations and improve symptoms for patients with congestive heart failure. We sought to create and pilot test such a program for patients with low literacy skills. We used focus groups and individual cognitive response interviews (CRIs) to develop an educational booklet for low literacy patients with heart failure. We incorporated the booklet into a disease management intervention that also included an initial individualized 1-h educational session and scheduled supportive phone calls that were tapered over 6 weeks. We then conducted a 3-month before-after study on patients with low literacy skills (<9th grade literacy level) in a university internal medicine clinic to test the acceptability and efficacy of our program. Outcomes of interest included heart failure-related knowledge, self-care behavior and heart failure-related symptoms measured on the Minnesota Living with Heart Failure (MLwHF) scale. Twenty-five patients were enrolled and 23 (92%) completed 3-month follow-up. Mean age was 60 years (range 35-74), 60% were men, 60% were African-American, and 74% had household income under $15,000 per year. The median reading level was fifth grade with 32% reading at or below the third grade level. Mean knowledge score at baseline was 67% and did not improve after the intervention. The proportion of patients reporting weighing themselves daily increased from 32% at baseline to 100% at 12 weeks. Mean improvement on the MLwHF scale was 9.9 points over the 3-month trial (95% CI: 0.5, 19.2), which corresponds to an improvement in one class on the New York Heart Association heart failure scale. A heart failure disease management program designed specifically for patients with low literacy skills is acceptable and is associated with improvement in self-care behavior and heart failure related symptoms.
ERIC Educational Resources Information Center
Chicago Heart Association, IL.
This handbook for nutritionists and dietitians as well as other health professionals (physicians, nurses, and health educators) is a guide to the content and conduct of the Heart Saver Program, a health education program designed to help prevent heart disease by bringing about significant changes in the food habits of the public. The content…
Oxygen and carbon dioxide transport in time-dependent blood flow past fiber rectangular arrays
NASA Astrophysics Data System (ADS)
Zierenberg, Jennifer R.; Fujioka, Hideki; Hirschl, Ronald B.; Bartlett, Robert H.; Grotberg, James B.
2009-03-01
The influence of time-dependent flows on oxygen and carbon dioxide transport for blood flow past fiber arrays arranged in in-line and staggered configurations was computationally investigated as a model for an artificial lung. Both a pulsatile flow, which mimics the flow leaving the right heart and passing through a compliance chamber before entering the artificial lung, and a right ventricular flow, which mimics flow leaving the right heart and directly entering the artificial lung, were considered in addition to a steady flow. The pulsatile flow was modeled as a sinusoidal perturbation superimposed on a steady flow while the right ventricular flow was modeled to accurately depict the period of flow acceleration (increasing flow) and deceleration (decreasing flow) during systole followed by zero flow during diastole. It was observed that the pulsatile flow yielded similar gas transport as compared to the steady flow, while the right ventricular flow resulted in smaller gas transport, with the decrease increasing with Re. The pressure drop across the fiber array (a measure of the resistance), work (an indicator of the work required of the right heart), and shear stress (a measure of potential blood cell activation and damage) are lowest for steady flow, followed by pulsatile flow, and then right ventricular flow. The pressure drop, work, shear stress, and Sherwood numbers (a measure of the gas transport efficiency) decrease with increasing porosity and are smaller for AR <1 as compared to AR >1 (AR is the distance between fibers in the flow direction/distance between fibers in direction perpendicular to flow), although for small porosities the Sherwood numbers are of similar magnitude. In general, for any fiber array geometry, high pressure drop, work, and shear stresses correlate with high Sherwood numbers, and low pressure drop, work, and shear stresses correlate with low Sherwood numbers creating a need for a compromise between pressure drop/work/shear stresses and gas transport.
NASA Astrophysics Data System (ADS)
Bayuwati, Dwi; Waluyo, Tomi B.; Widiyatmoko, Bambang
2015-01-01
An optical fiber optic sensor for detecting land displacement is discussed in this paper. The sensor system consists of a laser at wavelength 1.3 um, optical fiber coupler, optical fiber as sensor and light transmitting media, PIN photodiodedetector system, data logger and personal computer. Sensor was made from a curved optical fiber with diameter 35 mm, which will be changed into a heart-shape fiber if it is pulled. The heart-shape fiber sensor is the modification of the earlier displacement fiber sensor model which was in an ellipse form. Light to and from the optical fiber sensor was transmitted into a length of a multi core, single mode optical fiber cable. The scheme of the optical displacement sensor system has been described here. Characterization in the laboratory has been done by applying a series of pulling mechanism, on the heart-shape fiber sensor; which represents the land displacement process. Characterization in the field was carried out by mounting the sensor system on a scaled-down model of a land slope and artificially reproducing the landslide process using a steady-flow of artificial rainfall as the trigger. The voltage sensor output was recorded during the artificial landslide process. The displacement occurence can be indicated from the declining of the sensor signal received by the detector while the reference signal is steady. Characterization in the laboratory resulted in the performance of the optical fiber land displacement, namely, sensitivity 0.027(mV/mV)/mm, resolution 0.37 mm and measurement range 30 mm; compared with earlier optical fiber sensor performance with similar sensitivity and resolution which works only in 8 mm displacement range. Based on the experiment of landslides simulation in the field, we can define a critical condition in the real situation before landslides occurence to take any measures to prevent more casualties and losses.
Reich, H J; Morgan, J; Arabia, F; Czer, L; Moriguchi, J; Ramzy, D; Esmailian, F; Lam, L; Dunhill, J; Volod, O
2017-08-01
Essentials Bleeding is a major source of morbidity during mechanical circulatory support. von Willebrand factor (VWF) multimer loss may contribute to bleeding. Different patterns of VWF multimer loss were seen with the two device types. This is the first report of total artificial heart associated VWF multimer loss. Background Bleeding remains a challenge during mechanical circulatory support and underlying mechanisms are incompletely understood. Functional von Willebrand factor (VWF) impairment because of loss of high-molecular-weight multimers (MWMs) produces acquired von Willebrand disease (VWD) after left ventricular assist device (LVAD). Little is known about VWF multimers with total artificial hearts (TAHs). Here, VWF profiles with LVADs and TAHs are compared using a VWD panel. Methods VWD evaluations for patients with LVAD or TAH (2013-14) were retrospectively analyzed and included: VWF activity (ristocetin cofactor, VWF:RCo), VWF antigen (VWF:Ag), ratio of VWF:RCo to VWF:Ag, and quantitative VWF multimeric analysis. Results Twelve patients with LVADs and 12 with TAHs underwent VWD evaluation. All had either normal (47.8%) or elevated (52.2%) VWF:RCo, normal (26.1%) or elevated (73.9%) VWF:Ag and 50.0% were disproportional (ratio ≤ 0.7). Multimeric analysis showed abnormal patterns in all patients with LVADs: seven with high MWM loss; five with highest MWM loss. With TAH, 10/12 patients had abnormal patterns: all with highest MWM loss. High MWM loss correlated with presence of LVAD and highest MWM loss with TAH. Increased low MWMs were detected in 22/24. Conclusion Using VWF multimeric analysis, abnormalities after LVAD or TAH were detected that would be missed with measurements of VWF level alone: loss of high MWM predominantly in LVAD, loss of highest MWM in TAH, and elevated levels of low MWM in both. This is the first study to describe TAH-associated highest MWM loss, which may contribute to bleeding. © 2017 International Society on Thrombosis and Haemostasis.
Ivanov, K P
2014-01-01
The arrest of respiration during deep hypothermia means death, though at a low temperature the heart may rhythmically contract for 30-40 minutes more. The attempts of rewarming only shorten the time before the heart arrest. Calcium ions (Ca2+) are believed to accumulate in the nervous cells in cold. An excess of these ions inhibits the metabolism. Moreover it stimulates the cell proteases, which destroy the cell membranes. The aim of the study was to make the the attempts to develop the methods of stimulating the respiration and heart without rewarming the body. The work was carried out on wite rats 250-320g in weight. We introduced disodium salt of ethylenediaminetetraacetic acid into the animals. The second method of blocking the mechanisms of the cold death was artificial respiration. Ethylenediaminetetraacetic acid reacts with calcium ions, decreases their quantity in the blood, and, consequently, in a complex manner in the cell protoplasm. Artificial respiration not only increases the flow of oxygen into an organism but also decreases the lowest temperature threshold of the cold death of an organism. A decrease in the surviving threshold by 1.5-1.8 degrees C is very important from the point of view of reanimation of an organism since to preserve life in the critical period of reanimation each 0.5 degrees C are important. Prolongation of minimal frequency of heart contractions and maintaining a minimal arterial blood pressure in an overcooled organism given the body temperature of 11-12.5 degrees C is a special problem of great interest associated with many physiological and biological parameters.
Cardiovascular simulator improvement: pressure versus volume loop assessment.
Fonseca, Jeison; Andrade, Aron; Nicolosi, Denys E C; Biscegli, José F; Leme, Juliana; Legendre, Daniel; Bock, Eduardo; Lucchi, Julio Cesar
2011-05-01
This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Arabía, Francisco A; Cantor, Ryan S; Koehl, Devin A; Kasirajan, Vigneshwar; Gregoric, Igor; Moriguchi, Jaime D; Esmailian, Fardad; Ramzy, Danny; Chung, Joshua S; Czer, Lawrence S; Kobashigawa, Jon A; Smith, Richard G; Kirklin, James K
2018-04-26
We sought to better understand the patient population who receive a temporary total artificial heart (TAH) as bridge to transplant or as bridge to decision by evaluating data from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) database. We examined data related to survival, adverse events, and competing outcomes from patients who received TAHs between June 2006 and April 2017 and used hazard function analysis to explore risk factors for mortality. Data from 450 patients (87% men; mean age, 50 years) were available in the INTERMACS database. The 2 most common diagnoses were dilated cardiomyopathy (50%) and ischemic cardiomyopathy (20%). Risk factors for right heart failure were present in 82% of patients. Most patients were INTERMACS Profile 1 (43%) or 2 (37%) at implantation. There were 266 patients who eventually underwent transplantation, and 162 died. Overall 3-, 6-, and 12-month actuarial survival rates were 73%, 62%, and 53%, respectively. Risk factors for death included older age (p = 0.001), need for pre-implantation dialysis (p = 0.006), higher creatinine (p = 0.008) and lower albumin (p < 0.001) levels, and implantation at a low-volume center (≤10 TAHs; p < 0.001). Competing-outcomes analysis showed 71% of patients in high-volume centers were alive on the device or had undergone transplantation at 12 months after TAH implantation vs 57% in low-volume centers (p = 0.003). Patients receiving TAHs have rapidly declining cardiac function and require prompt intervention. Experienced centers have better outcomes, likely related to patient selection, timing of implantation, patient care, and device management. Organized transfer of knowledge to low-volume centers could improve outcomes. Copyright © 2018 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
76 FR 10907 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-28
... Project Division of Heart Disease and Stroke Prevention Management Information System--Revision--National... Prevention (CDC). Background and Brief Description CDC's Division of Heart Disease and Stroke Prevention... two programs: The National Heart Disease and Stroke Prevention Program (NHDSPP), and the Well...
The Artificial Intelligence Applications to Learning Programme.
ERIC Educational Resources Information Center
Williams, Noel
1992-01-01
Explains the Artificial Intelligence Applications to Learning Programme, which was developed in the United Kingdom to explore and accelerate the use of artificial intelligence (AI) technologies in learning in both the educational and industrial sectors. Highlights include program evaluation, marketing, ownership of information, consortia, and cost…
Tissue engineering and cell-based therapy toward integrated strategy with artificial organs.
Gojo, Satoshi; Toyoda, Masashi; Umezawa, Akihiro
2011-09-01
Research in order that artificial organs can supplement or completely replace the functions of impaired or damaged tissues and internal organs has been underway for many years. The recent clinical development of implantable left ventricular assist devices has revolutionized the treatment of patients with heart failure. The emerging field of regenerative medicine, which uses human cells and tissues to regenerate internal organs, is now advancing from basic and clinical research to clinical application. In this review, we focus on the novel biomaterials, i.e., fusion protein, and approaches such as three-dimensional and whole-organ tissue engineering. We also compare induced pluripotent stem cells, directly reprogrammed cardiomyocytes, and somatic stem cells for cell source of future cell-based therapy. Integrated strategy of artificial organ and tissue engineering/regenerative medicine should give rise to a new era of medical treatment to organ failure.
Three-dimentional simulation of flow-induced platelet activation in artificial heart valves
NASA Astrophysics Data System (ADS)
Hedayat, Mohammadali; Asgharzadeh, Hafez; Borazjani, Iman
2015-11-01
Since the advent of heart valve, several valve types such as mechanical and bio-prosthetic valves have been designed. Mechanical Heart Valves (MHV) are durable but suffer from thromboembolic complications that caused by shear-induced platelet activation near the valve region. Bio-prosthetic Heart Valves (BHV) are known for better hemodynamics. However, they usually have a short average life time. Realistic simulations of heart valves in combination with platelet activation models can lead to a better understanding of the potential risk of thrombus formation in such devices. In this study, an Eulerian approach is developed to calculate the platelet activation in three-dimensional simulations of flow through MHV and BHV using a parallel overset-curvilinear immersed boundary technique. A curvilinear body-fitted grid is used for the flow simulation through the anatomic aorta, while the sharp-interface immersed boundary method is used for simulation of the Left Ventricle (LV) with prescribed motion. In addition, dynamics of valves were calculated numerically using under-relaxed strong-coupling algorithm. Finally, the platelet activation results for BMV and MHV are compared with each other.
Barrios, V; Escobar, C; Pallares, V; Egocheaga, M I; Lobos, J M; Bover, R; Gómez Doblas, J J; Cosín, J
2018-03-26
Despite current treatments, morbidity and mortality of patients with heart failure remain high. The late diagnosis of heart failure, the insufficient heart failure treatment (i.e. not using the appropriate drugs, prescribing lower doses of drugs than recommended, etc.), and a poor coordination between different health care levels, may explain, at least in part, these figures. The Management of Heart Failure in Cardiology and Primary Care (MICCAP) program has been developed with the aim of optimising the integrated management of patients with heart failure between Primary Care and Cardiology, through the improvement of coordination between both health care levels. This includes continuous medical education to reinforce the diagnostic and therapeutic skills of general practitioners in the field of heart failure. The rationale and objectives of the MICCAP program are summarised in this article. Copyright © 2018 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.
Exploiting Artificial Intelligence To Enhance Training: A Short- and Medium-Term Perspective.
ERIC Educational Resources Information Center
Cumming, Geoff
This paper is an introductory discussion of industrial training, artificial intelligence (AI), and AI applications in training, prepared in the context of the United Kingdom Training Commission (TC) program. Following an outline of the activities and aims of the program, individual sections describe perspectives on: (1) training needs, including…
PROLOG to the Future: A Glimpse of Things to Come in Artificial Intelligence.
ERIC Educational Resources Information Center
Herther, Nancy K.
1986-01-01
Briefly introduces the programming languages of artificial intelligence and presents information on some of the new versions of these languages available for microcomputers. A tutorial for PROLOG-86, a new microcomputer version of PROLOG, is given. Information on other microcomputer versions of these programs and a bibliography are included.…
Experimental study on the effect of an artificial cardiac valve on the left ventricular flow
NASA Astrophysics Data System (ADS)
Wang, JiangSheng; Gao, Qi; Wei, RunJie; Wang, JinJun
2017-09-01
The use of artificial valves to replace diseased human heart valves is currently the main solution to address the malfunctioning of these valves. However, the effect of artificial valves on the ventricular flow still needs to be understood in flow physics. The left ventricular flow downstream of a St. Jude Medical (SJM) bileaflet mechanical heart valve (BMHV), which is a widely implanted mechanical bileaflet valve, is investigated with time-resolved particle image velocimetry in the current work. A tilting-disk valve is installed on the aortic orifice to guarantee unidirectional flow. Several post-processing tools are applied to provide combined analyses of the physics involved in the ventricular flow. The triple jet pattern that is closely related to the characteristics of the bileaflet valve is discussed in detail from both Eulerian and Lagrangian views. The effects of large-scale vortices on the transportation of blood are revealed by the combined analysis of the tracking of Lagrangian coherent structures, the Eulerian monitoring of the shear stresses, and virtual dye visualization. It is found that the utilization of the SJM BMHV complicates the ventricular flow and could reduce the efficiency of blood transportation. In addition, the kinematics of the bileaflets is presented to explore the effects of flow structures on their motion. These combined analyses could elucidate the properties of SJM BMHV. Furthermore, they could provide new insights into the understanding of other complex blood flows.
Artificial Intelligence and Autonomy: Opportunities and Challenges
2017-10-01
Cleared for Public Release Artificial Intelligence & Autonomy Opportunities and Challenges Andrew Ilachinski October 2017 Copyright © 2017 CNA... Artificial Intelligence & Autonomy Opportunities and 5a. CONTRACT NUMBER N00014-16-D-5003 Challenges 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 0605154N...conducted by unmanned and increasingly autonomous weapon systems. This exploratory study considers the state-of-the-art of artificial intelligence (AI
Artificial Intelligence Project
1990-01-01
Artifcial Intelligence Project at The University of Texas at Austin, University of Texas at Austin, Artificial Intelligence Laboratory AITR84-01. Novak...Texas at Austin, Artificial Intelligence Laboratory A187-52, April 1987. Novak, G. "GLISP: A Lisp-Based Programming System with Data Abstraction...of Texas at Austin, Artificial Intelligence Laboratory AITR85-14.) Rim, Hae-Chang, and Simmons, R. F. "Extracting Data Base Knowledge from Medical
Thermally induced magnetic relaxation in square artificial spin ice
Andersson, M. S.; Pappas, S. D.; Stopfel, H.; ...
2016-11-24
The properties of natural and artificial assemblies of interacting elements, ranging from Quarks to Galaxies, are at the heart of Physics. The collective response and dynamics of such assemblies are dictated by the intrinsic dynamical properties of the building blocks, the nature of their interactions and topological constraints. Here in this paper, we report on the relaxation dynamics of the magnetization of artificial assemblies of mesoscopic spins. In our model nano-magnetic system $-$ square artificial spin ice $-$ we are able to control the geometrical arrangement and interaction strength between the magnetically interacting building blocks by means of nano-lithography. Usingmore » time resolved magnetometry we show that the relaxation process can be described using the Kohlrausch law and that the extracted temperature dependent relaxation times of the assemblies follow the Vogel-Fulcher law. The results provide insight into the relaxation dynamics of mesoscopic nano-magnetic model systems, with adjustable energy and time scales, and demonstrates that these can serve as an ideal playground for the studies of collective dynamics and relaxations.« less
Thermally induced magnetic relaxation in square artificial spin ice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersson, M. S.; Pappas, S. D.; Stopfel, H.
The properties of natural and artificial assemblies of interacting elements, ranging from Quarks to Galaxies, are at the heart of Physics. The collective response and dynamics of such assemblies are dictated by the intrinsic dynamical properties of the building blocks, the nature of their interactions and topological constraints. Here in this paper, we report on the relaxation dynamics of the magnetization of artificial assemblies of mesoscopic spins. In our model nano-magnetic system $-$ square artificial spin ice $-$ we are able to control the geometrical arrangement and interaction strength between the magnetically interacting building blocks by means of nano-lithography. Usingmore » time resolved magnetometry we show that the relaxation process can be described using the Kohlrausch law and that the extracted temperature dependent relaxation times of the assemblies follow the Vogel-Fulcher law. The results provide insight into the relaxation dynamics of mesoscopic nano-magnetic model systems, with adjustable energy and time scales, and demonstrates that these can serve as an ideal playground for the studies of collective dynamics and relaxations.« less
NASA Astrophysics Data System (ADS)
Marijke, Grau; Vera, Abeln; Tobias, Vogt; Wilhelm, Bloch; Stefan, Schneider
2017-02-01
Artificial gravity protocols are used to improve g-tolerance of aviators and discussed as countermeasure during prolonged space flight. Little is known about the impact of artificial gravity on the red blood cells (RBC). The purpose of the study was to test how artificial gravity affects RBC deformability and aggregation, which are important determinants of microcirculation. Nine male subjects were exposed to two hypergravity protocols using a short arm human centrifuge: a continuous (CONT) protocol with constant +2 Gz for 30 min and an intermittent (INTER) protocol with repeated intervals of +2 Gz and rest. Blood was sampled pre and post interventions to measure basal blood parameters, RBC nitrite, RBC deformability, aggregation, and to determine the shear rate balancing aggregation and disaggregation (γ at dIsc min). To test for orthostasis effects, five male subjects were asked to stay for 46 min, corresponding to the length of the centrifuge protocols, with blood sampling pre and post intervention. Artificial gravity programs did not affect basal blood parameters or RBC nitrite levels; a marker for RBC deformability influencing nitric oxide. The INTER program did not affect any of the tested parameters. The CONT program did not remarkably affect RBC deformability or γ at dIsc min but significantly aggravated aggregation. Orthostasis effects were thus excluded. The results indicate that continuous artificial gravity, especially with higher g-forces applied, may negatively affect the RBC system and that for a prolonged space flight intermittent but not continuous artificial gravity might represent an appropriate countermeasure.
Artificial intelligence - NASA. [robotics for Space Station
NASA Technical Reports Server (NTRS)
Erickson, J. D.
1985-01-01
Artificial Intelligence (AI) represents a vital common space support element needed to enable the civil space program and commercial space program to perform their missions successfully. It is pointed out that advances in AI stimulated by the Space Station Program could benefit the U.S. in many ways. A fundamental challenge for the civil space program is to meet the needs of the customers and users of space with facilities enabling maximum productivity and having low start-up costs, and low annual operating costs. An effective way to meet this challenge may involve a man-machine system in which artificial intelligence, robotics, and advanced automation are integrated into high reliability organizations. Attention is given to the benefits, NASA strategy for AI, candidate space station systems, the Space Station as a stepping stone, and the commercialization of space.
Aengwanich, Worapol; Kongbuntad, Watee; Boonsorn, Thongchai
2011-09-01
The purpose of this study was to assess the effects of artificial shade, tree shade, and no shade on physiological changes, oxidative stress, and total antioxidant power in Thai Brahman cattle. Twenty-one cattle were divided into three groups: cattle maintained under artificial shade, under tree shade, and without shade. On days 1, 7, 14, 21, and 28 of the experimental period, after the cattle were set in individual stalls for 2 h, physiological changes, thiobarbituric acid reactive substances (TBARS), and total antioxidant power were investigated. The results revealed that the respiratory rate, heart rate, sweat rate and the neutrophil/lymphocyte ratio of the no-shade cattle were significantly higher than those of cattle maintained under artificial shade and tree shade (P < 0.05). During the early period of heat exposure, the total antioxidant power of the no-shade cattle was lower than those of cattle maintained under artificial shade and tree shade, but the total antioxidant power of cattle maintained under artificial shade and tree shade were not different (P > 0.05). However, rectal temperature and packed cell volume of the cattle in all groups did not differ (P > 0.05). These results showed that artificial shade and tree shade can protect cattle from sunlight compared to no shade, and that the effectiveness of tree shade for sunlight protection is at an intermediate level.
2011-05-01
leg prosthesis for above-the-knee amputees currently commercialized by Ossur hf and developed by Victhom Human Bionics Inc., a medical device...did not feel they worked as hard when wearing the K-SRDTM version POC during the loaded conditions. However, based on our heart rate measured, there
Women's Heart Advantage Program: the impact 3 years later.
Gombeski, William R; Kramer, R Kyle; Freed, Lisa; Foody, JoAnne; Parkosewich, Janet; Wilson, Tammi; Wack, Jeffery T; D'Onofrio, Gail
2005-01-01
Yale-New Haven Hospital, in partnership with Voluntary Hospital Association (VHA Inc), launched the Women's Heart Advantage program in March 2001. Major program components implemented include (1) a comprehensive initial and ongoing internal communication program; (2) a health promotion initiative including a 24-hour, 7-days-a-week women's heart line staffed by nurses and an Internet health question-and-answer forum; (3) significant ongoing communication with nurses and physicians; (4) a community outreach effort to educate poor and minority women; and (5) an aggressive effort to secure financial partners to underwrite the cost of the program. Before launching the program, a telephone survey of 300 randomly selected New Haven County women ages 40 to 70 years was initiated in January 2001 and repeated in January 2002, 2003, and 2004. Findings include (1) the percentage of women who recognize heart disease as the number-one killer of women their age increased from 26% in 2001 to 59% in 2004, (2) the percentage of women who would call 9-1-1 or go directly to a hospital emergency department increased from 63% in 2002 to 83% in 2004, and (3) the percentage of women aware of recent Women's Heart Advantage program promotion grew from 33% in 2002 to 50% in 2004. Perhaps most importantly, the number of women with heart problems admitted through the hospital's emergency department increased from 1528 per year in 2001 to 1870 per year in 2004 (7.5% annual increase), whereas the number of men with heart problems admitted through the emergency department during the same time period has been relatively low (0.8% annual increase). By linking clinical, public health, and marketing expertise along with finding ways to partner with other organizations, the Women's Heart Advantage program has contributed to remarkable changes in women's awareness, knowledge, and behaviors, suggesting a model for approaching similar health-related problems.
Jones, Deborah E; Weaver, Michael T; Friedmann, Erika
2007-07-01
The purpose of this study was to evaluate the effectiveness of a 5-week, 1 hour per week heart disease prevention program for sedentary female municipal workers with known heart disease risk factors. The program was designed to improve participants' knowledge and perceptions of their personal susceptibility to heart disease. In targeting an ethnically diverse, lower income working population, the researchers also sought to contribute to one of the goals of Healthy People 2010, the elimination of health disparities, specifically the reduction of health disparities in heart disease by 25% by the year 2010. A one-group, repeated measures, quasi-experimental design was employed. Forty-eight women 25 to 66 years old responded to the solicitation and participated in the program. Seventy-five percent were African American, 23% were White, and 2% were Latino. Participants completed a 33-item heart disease knowledge questionnaire, demographic questions, and a single visual analog scale statement to assess perceived susceptibility. Fifty-eight percent of the participants improved their knowledge of heart disease and 50% of the participants increased their perception of susceptibility to heart disease from pre- to post-intervention. The greatest improvement in knowledge and awareness of susceptibility occurred for those with limited knowledge and low perceptions of susceptibility. The gains from this workplace health education project for largely minority female municipal workers were modest, but notable. A workplace health education program for women targeted at increasing their knowledge of heart disease may also increase their perceptions of susceptibility to heart disease.
ALOG user's manual: A Guide to using the spreadsheet-based artificial log generator
Matthew F. Winn; Philip A. Araman; Randolph H. Wynne
2012-01-01
Computer programs that simulate log sawing can be valuable training tools for sawyers, as well as a means oftesting different sawing patterns. Most available simulation programs rely on diagrammed-log databases, which canbe very costly and time consuming to develop. Artificial Log Generator (ALOG) is a user-friendly Microsoft® Excel®...
Space Station Mission Planning System (MPS) development study. Volume 2
NASA Technical Reports Server (NTRS)
Klus, W. J.
1987-01-01
The process and existing software used for Spacelab payload mission planning were studied. A complete baseline definition of the Spacelab payload mission planning process was established, along with a definition of existing software capabilities for potential extrapolation to the Space Station. This information was used as a basis for defining system requirements to support Space Station mission planning. The Space Station mission planning concept was reviewed for the purpose of identifying areas where artificial intelligence concepts might offer substantially improved capability. Three specific artificial intelligence concepts were to be investigated for applicability: natural language interfaces; expert systems; and automatic programming. The advantages and disadvantages of interfacing an artificial intelligence language with existing FORTRAN programs or of converting totally to a new programming language were identified.
New Types of Artificial Muscles for Large Stroke and High Force Applications
2012-10-10
University of Texas at Dallas and include Aerogel Muscles, Torsional and Tensile Yarn Muscles, Artificial Muscles Based on Polypyrrole Laminates and...Stroke, Superelastic Carbon Nanotube Aerogel Muscles 3. Torsional and Tensile Carbon Nanotube Yarn Muscles 4. Artificial Muscles Based on...in numerous press releases and TV programs. As we reported in Science 2009, carbon nanotube aerogel sheets are the sole component of new artificial
Trimaran Resistance Artificial Neural Network
2011-01-01
11th International Conference on Fast Sea Transportation FAST 2011, Honolulu, Hawaii, USA, September 2011 Trimaran Resistance Artificial Neural Network Richard...Trimaran Resistance Artificial Neural Network 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e... Artificial Neural Network and is restricted to the center and side-hull configurations tested. The value in the parametric model is that it is able to
2014-01-01
To enhance ambulation and facilitate hospital discharge of total artificial heart (TAH)–supported patients, we adapted a mobile ventricular assistance device (VAD) driver (Excor) for TAH use and report on the performance of Excor-driven TAH patients discharged home. Ten patients stabilized on a TAH, driven by the CSS (“Circulatory Support System”), were progressively switched over to the Excor in hospital over 14 days as a pilot, with daily hemodynamics and laboratory parameters measured. Twenty-two stable TAH patients were subsequently placed on the Excor, trained, and discharged home. Clinical and hemodynamic parameters were followed. All pilot study patients were clinically stable on the Excor, with no decrease in TAH output noted (6.3 + 0.3 L/min [day 1] vs. 5.8 + 0.2 L/min [day 14], p = 0.174), with a trend suggesting improvement of both hepatic and renal function. Twenty-two TAH patients were subsequently successfully discharged home on the portable driver and were supported out of hospital for up to 598 days (range, 2–598; mean = 179 ± 140 days), remaining ambulatory, New York Heart Association (NYHA) class I or II, and free of readmission for 88.5% of the time of support. TAH patients may be effectively and safely supported by a mobile drive system. As such, the utility of the TAH may be extended to support patients beyond the hospital, at home, with overall ambulatory freedom. PMID:24577369
Balcázar, Héctor; Alvarado, Matilde; Hollen, Mary Luna; Gonzalez-Cruz, Yanira; Pedregón, Verónica
2005-07-01
In 2001, the National Heart, Lung, and Blood Institute partnered with the National Council of La Raza to conduct a pilot test of its community-based outreach program Salud Para Su Corazón (Health for Your Heart), which aims to reduce the burden of morbidity and mortality associated with cardiovascular disease among Latinos. The effectiveness of promotores de salud (community health workers) in improving heart-healthy behaviors among Latino families participating in the pilot program at seven sites was evaluated. Data on the characteristics of the promotores in the Salud Para Su Corazón program were compiled. Promotores collected data on family risk factors, health habits, referrals and screenings, information sharing, and program satisfaction from 223 participating Latino families (320 individual family members) through questionnaires. Paired t tests and chi-square tests were used to measure pretest-posttest differences among program participants. Results demonstrated the effectiveness of the promotora model in improving heart-healthy behaviors, promoting community referrals and screenings, enhancing information sharing beyond families, and satisfying participants' expectations of the program. The main outcome of interest was the change in heart-healthy behaviors among families. The community outreach model worked well in the seven pilot programs because of the successes of the promotores and the support of the community-based organizations. Successes stemmed in part from the train-the-trainer approach. Promotoria, as implemented in this program, has the potential to be integrated with a medical model of patient care for primary, secondary, and tertiary prevention.
Hannula, Manne; Huttunen, Kerttu; Koskelo, Jukka; Laitinen, Tomi; Leino, Tuomo
2008-01-01
In this study, the performances of artificial neural network (ANN) analysis and multilinear regression (MLR) model-based estimation of heart rate were compared in an evaluation of individual cognitive workload. The data comprised electrocardiography (ECG) measurements and an evaluation of cognitive load that induces psychophysiological stress (PPS), collected from 14 interceptor fighter pilots during complex simulated F/A-18 Hornet air battles. In our data, the mean absolute error of the ANN estimate was 11.4 as a visual analog scale score, being 13-23% better than the mean absolute error of the MLR model in the estimation of cognitive workload.
Wilinski, Bogdan; Opoka, Wlodzimierz; Somogyi, Eugeniusz; Piotrowska, Joanna; Wilinski, Jerzy
The interactions among natural and artificial sweeteners and endogenous sulfur metabolism have never been investigated. CBA strain mice were administered orally stevia, cyclamate or saccharin in doses of 5 mg/kg of body weight in water solutions each. The measurements of the free and acid-labile sulfane (H2S) tissue concentrations in brain, heart, liver and kidney were performed with Siegel spectrophotometric modified method. No differences in comparisons between hydrogen sulfide concentrations in the control group and each sweetener group within every tissue type were noted. In conclusion, stevia, cyclamate and saccharine do not change the endogenous sulfur metabolism to the extent of causing sulfane tissue levels alterations.
Effectiveness of the Complete Health Improvement Program
ERIC Educational Resources Information Center
Hutchins, Mathew; Melancon, Jim; Sneed, Demarcus; Nunning, Jennifer
2015-01-01
Currently, heart disease and diabetes dominate society as the leading cause of death for Americans. In this study, we examined the effectiveness of a lifestyle enhancement program on factors related to the development of heart disease. The Wabash Valley Complete Health Improvement Program (CHIP) is a community-based lifestyle change program with…
2016-09-01
other associated grants. 15. SUBJECT TERMS SUNY Poly, STEM, Artificial Intelligence , Command and Control 16. SECURITY CLASSIFICATION OF: 17...neuromorphic system has the potential to be widely used in a high-efficiency artificial intelligence system. Simulation results have indicated that the...novel multiresolution fusion and advanced fusion performance evaluation tool for an Artificial Intelligence based natural language annotation engine for
Exercise Following a Heart Attack: Some Special Considerations.
ERIC Educational Resources Information Center
Fardy, Paul S.
This paper presents information on the effectiveness of exercise programs for heart attack victims. Some of the observations come from unpublished results of a two year experiment of the National Exercise and Heart Disease Project. The paper first establishes that a group exercise program with trained supervision is advantageous for people with…
ERIC Educational Resources Information Center
Sayre, Scott Alan
The ultimate goal of the science of artificial intelligence (AI) is to establish programs that will use algorithmic computer techniques to imitate the heuristic thought processes of humans. Most AI programs, especially expert systems, organize their knowledge into three specific areas: data storage, a rule set, and a control structure. Limitations…
1982-12-01
Paris, France, June, 1982, 519-530. Latoinbe, J. C. "Equipe Intelligence Artificielle et Robotique: Etat d’avancement des recherches," Laboratoire...8217AD-A127 233 ROBOT PROGRRMMING(U) MASSACHUSETTS INST OFGTECHi/ CAMBRIDGE ARTIFICIAL INTELLIGENCE LAB T LOZANO-PEREZ UNCLASSIFIED DC8 AI-9 N884...NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK Artificial Intelligence Laboratory AREA I WORK UNIT NUMBERS ,. 545 Technology Square Cambridge
Xinyinqin: a computer-based heart sound simulator.
Zhan, X X; Pei, J H; Xiao, Y H
1995-01-01
"Xinyinqin" is the Chinese phoneticized name of the Heart Sound Simulator (HSS). The "qin" in "Xinyinqin" is the Chinese name of a category of musical instruments, which means that the operation of HSS is very convenient--like playing an electric piano with the keys. HSS is connected to the GAME I/O of an Apple microcomputer. The generation of sound is controlled by a program. Xinyinqin is used as a teaching aid of Diagnostics. It has been applied in teaching for three years. In this demonstration we will introduce the following functions of HSS: 1) The main program has two modules. The first one is the heart auscultation training module. HSS can output a heart sound selected by the student. Another program module is used to test the student's learning condition. The computer can randomly simulate a certain heart sound and ask the student to name it. The computer gives the student's answer an assessment: "correct" or "incorrect." When the answer is incorrect, the computer will output that heart sound again for the student to listen to; this process is repeated until she correctly identifies it. 2) The program is convenient to use and easy to control. By pressing the S key, it is able to output a slow heart rate until the student can clearly identify the rhythm. The heart rate, like the actual rate of a patient, can then be restored by hitting any key. By pressing the SPACE BAR, the heart sound output can be stopped to allow the teacher to explain something to the student. The teacher can resume playing the heart sound again by hitting any key; she can also change the content of the training by hitting RETURN key. In the future, we plan to simulate more heart sounds and incorporate relevant graphs.
Fluid dynamics of heart assist device
NASA Technical Reports Server (NTRS)
Jones, R. T.
1976-01-01
Certain hemodynamic phenomena that arise in connection with the use of artificial blood pumping devices are reviewed. Among these are: (1) Flows produced by collapsing bulbs; (2) the impedance presented by the aorta; (3) limiting velocities and instability of flow in elastic vessels; (4) effectiveness of valveless arterio-arterial pumps, and (5) wave reflection phenomena and instabilities associated with the intra-aortic balloon pump.
Baspinar, Osman; Sahin, Derya A; Yildirim, Ali
2016-04-01
We present the case report of a war victim child with severe burn scars, orthopnoea, and dyspnoea due to diffuse pulmonary thromboembolism. During ICU stay, a central venous catheter's 45-mm wire embolised into the heart. The embolised wire was successfully removed via transhepatic access through the creation of an artificial simple snare.
What a Decade of Experiments Reveals about Factors that Influence the Sense of Presence
2006-03-01
Function HRV heart rate variability IBM International Business Machines Corporation ICAT International Conference on Artificial Intelligence and...Questionnaire. Person-related meas.: Social anxiety , age, gender, computer use. Task-related measures: Social anxiety assessment of partner. Performance...co-presence. (4) Computer use had a significant positive correlation with co-presence. (5) Participant’s social anxiety had a significant
Fracture and embolization of a Björk-Shiley disc. Fatal failure of a prosthetic mitral valve.
Norenberg, D D; Evans, R W; Gundersen, A E; Abellera, R M
1977-12-01
A case of fracture of the disc occluder of a Bjork-Shiley mitral prosthesis with embolization of the disc fragments to distal aorta is presented. The possibility of valve dysfunction and the diagnostic value of echocardiography should be considered whenever acute heart failure occurs in a patient with an artificial valve.
ERIC Educational Resources Information Center
Yates, Joanne M.
The ideas of John Dewey and his fellow progressives have resurfaced in a movement called "writing across the curriculum." Interdisciplinary studies are now being seen as a way to break down the artificial boundaries between subject areas. Research has confirmed that language learning and experience are at the heart of education. The implications…
2014-04-01
During last years in foreign countries there was widely introduced tactic of early activation of cardio-surgery patients. Necessary components of this methodical approach are early finishing of post-operation artificial respiration and extubation of trachea, shortening of time spending in intensive therapy till 1 day and sign out from stationary after 5 days. As a result of reducing hospitalization period, the curation costs are reduced significantly. Goal of this research was the analysis of methods of anesthesia that allow early extubation and activation after cardio-surgery interventions. There were analyzed data of protocols of anesthesia and post-operation periods for 270 patients. It was concluded that applied methods of anesthesia ensure adequate protection from operation stress and allow reduce time of post-operation artificial respiration, early activation of patients without reducing level of their safety. It was also proved that application of any type of anesthesia medicines is not influencing the temp of post-operation activation. Conducted research is proving the advisability of using tactic of early activation of patients after heart operations and considers this as a tool for optimization of cardio-surgery curation.
NASA Astrophysics Data System (ADS)
Shiba, Kenji; Koshiji, Kohji
Transcutaneous Energy Transmission (TET) is one way of providing the energy needed to power a totally implantable artificial heart (TIAH). In the present study, an externally coupled TET system was implanted in a prototype human phantom to evaluate emission and immunity. In the emission evaluation, measurements were conducted based on CISPR Pub.11 and VDE 0871 standards, while immunity tests were based on the standards of the IEC 61000-4 series. The magnetic field of the radiated emission was measured using a loop antenna. At 0.1[MHz], we found the greatest magnetic field of 47.8 [dBμA/m], somewhat less than CISPR’s upper limit of 54 [dBμA/m]. For the conducted emission, by installing a noise filter and ferrite beads in the input section of the DC-power supply, conducted emission could be kept within the allowable limits of CISPR Pub.11 and VDE 0871. Finally, the immunity tests against radiated and conducted emission, electrostatic discharge and voltage fluctuation proved that the prototype could withstand the maximum level of disturbance. These results confirmed that the TET system implanted in a human phantom could, through modification, meet the emission and immunity standards.
Driver electronics design and control for a total artificial heart linear motor.
Unthan, Kristin; Cuenca-Navalon, Elena; Pelletier, Benedikt; Finocchiaro, Thomas; Steinseifer, Ulrich
2018-01-27
For any implantable device size and efficiency are critical properties. Thus, a linear motor for a Total Artificial Heart was optimized with focus on driver electronics and control strategies. Hardware requirements were defined from power supply and motor setup. Four full bridges were chosen for the power electronics. Shunt resistors were set up for current measurement. Unipolar and bipolar switching for power electronics control were compared regarding current ripple and power losses. Here, unipolar switching showed smaller current ripple and required less power to create the necessary motor forces. Based on calculations for minimal power losses Lorentz force was distributed to the actor's four coils. The distribution was determined as ratio of effective magnetic flux through each coil, which was captured by a force test rig. Static and dynamic measurements under physiological conditions analyzed interaction of control and hardware and all efficiencies were over 89%. In conclusion, the designed electronics, optimized control strategy and applied current distribution create the required motor force and perform optimal under physiological conditions. The developed driver electronics and control offer optimized size and efficiency for any implantable or portable device with multiple independent motor coils. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Rizal, Umesh; Swain, Bhabani S.; Rameshbabu, N.; Swain, Bibhu P.
2018-01-01
Amorphous silicon carbide (a-SiC:H) thin films were synthesized using trichloromethylsilane by a hot wire chemical vapor deposition process. The deposited films were characterized by Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, x-ray diffraction and x-ray photoelectron spectroscopy to confirm its chemical bonding, structural network and composition of the a-SiC:H films. The optical microscopy images reveal that hydrogen dilution increased the surface roughness and pore density of a-SiC:H thin film. The Raman spectroscopy and FTIR spectra reveal chemical network consisting of Si-Si, C-C and Si-C bonds, respectively. The XRD spectroscopy and Raman spectroscopy indicate a-SiC:H still has short-range order. In addition, in vitro cytotoxicity test ensures the behavior of cell-semiconductor hybrid to monitor the proper coordination. The live-dead assays and MTT assay reveal an increase in green nucleus cell, and cell viability is greater than 88%, respectively, showing non-toxic nature of prepared a-SiC:H film. Moreover, the result indicated by direct contact assay, and cell prefers to adhere and proliferate on a-SiC:H thin films having a positive effect as artificial heart valve coating material.
Falletta, Calogero; Pasta, Salvatore; Raffa, Giuseppe Maria; Crinò, Francesca; Sciacca, Sergio; Clemenza, Francesco
2018-02-13
Use of continuous flow left ventricle assist device (CF-LVAD) in advanced heart failure (HF) patients results in clinically relevant improvements in survival, functional capacity, and quality of life. Peripheral artery disease (PAD) can occur in patients with CF-LVAD due to the high rate of concomitance between risk factors for atherosclerosis and HF. Diagnosis of PAD can be difficult in the specific setting of a patient supported by this kind of device because of the marked alteration in waveform morphology and velocity created by the artificial physiology of an LVAD. We report the case of a 53-year-old man with HF secondary to ischemic cardiomyopathy supported by the HeartWare HVAD as bridge to transplant, who after the implant developed symptoms suggestive of PAD. We describe additional computational flow analysis for the study of PAD-related hemodynamic disturbances induced by a CF-LVAD. Flow simulations enhance the information of clinical image data, and may have an application in clinical investigations of the risk of hemodynamic disturbances induced by LVAD implantation. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
A case study of the New York City trans-fat story for international application.
Tan, Andy S L
2009-04-01
Heart disease is the leading cause of death in New York City and contributes to significant burden of disease in the United States and internationally. Excessive intake of artificial trans-fatty acids has been causally associated with increased risk of heart disease. This article describes New York City's 2007 trans-fatty acids regulation, which was aimed at lowering the prevalence of heart disease among the city's residents by prohibiting the use of trans-fatty acids in the preparation of food in the city's food outlets. The author describes sequentially: (1) formulation, (2) public consultation, (3) implementation and (4) evaluation of the policy. He proposes a strategic framework for food policy development for international policymakers who are considering similar regulations. The framework includes four domains: (1) background research, (2) stakeholder support, (3) effective policy implementation and (4) evaluation and dissemination.
Frozen Plains in the Heart of Pluto Heart
2015-07-17
At center left of Pluto vast heart-shaped feature "Tombaugh Regio" -- lies a vast, craterless plain that appears to be no more than 100 million years old, and is possibly still being shaped by geologic processes as seen by NASA New Horizons spacecraft. This frozen region is north of Pluto's icy mountains and has been informally named Sputnik Planum (Sputnik Plain), after Earth's first artificial satellite. The surface appears to be divided into irregularly-shaped segments that are ringed by narrow troughs. Features that appear to be groups of mounds and fields of small pits are also visible. This image was acquired by the Long Range Reconnaissance Imager (LORRI) on July 14 from a distance of 48,000 miles (77,000 kilometers). Features as small as one-half mile (1 kilometer) across are visible. The blocky appearance of some features is due to compression of the image. http://photojournal.jpl.nasa.gov/catalog/PIA19841
Influence of red jersey color on physical parameters in combat sports.
Dreiskaemper, Dennis; Strauss, Bernd; Hagemann, Norbert; Büsch, Dirk
2013-02-01
Hill and Barton (2005) showed that fighters in tae kwon do, boxing, and wrestling who wore red jerseys during the 2004 Olympic Games won more often than those wearing blue jerseys. Regarding these results, this study investigated the effects of jersey color during a combat situation on fighters' physical parameters of strength and heart rate. An artificial, experimental combat situation was created in which the color of sport attire was assigned randomly. Fourteen pairs of male athletes matched for weight, height, and age had to fight each other: once in a red jersey and once in a blue. Heart rate (before, during, and after the fight) and strength (before the fight) were tested wearing the blue and the red jerseys. Participants wearing red jerseys had significantly higher heart rates and significantly higher pre-contest values on the strength test. Results showed that participants' body functions are influenced by wearing red equipment.
Resource management in cardiovascular engineering: is outsourcing the solution?
Feyrer, Richard; Weyand, Michael; Kunzmann, Udo
2005-09-01
In recent years, modern medicine has changed considerably. At maximum care centers, in particular, the use of state-of-the-art medical equipment has become an essential part of patient care. HoWever, using such high-tech products also means a considerable burden on the financial resources available, because additional financing is rare. Consequently, there is a need for approaches that allow the use of state-of-the-art equipment without straining the budget unduly. The question now is whether economic strategies that have long since been established in other industries, e.g., the outsourcing of certain services, represent a potential solution for the economic problems of modern clinics. The fundamentals of outsourcing and its pros and cons are outlined and discussed, taking cardiovascular perfusion as an example, a cost-intensive field of heart surgery that is responsible for attending to heart-lung machines, artificial hearts and circulatory support systems.
Detection of MRI artifacts produced by intrinsic heart motion using a saliency model
NASA Astrophysics Data System (ADS)
Salguero, Jennifer; Velasco, Nelson; Romero, Eduardo
2017-11-01
Cardiac Magnetic Resonance (CMR) requires synchronization with the ECG to correct many types of noise. However, the complex heart motion frequently produces displaced slices that have to be either ignored or manually corrected since the ECG correction is useless in this case. This work presents a novel methodology that detects the motion artifacts in CMR using a saliency method that highlights the region where the heart chambers are located. Once the Region of Interest (RoI) is set, its center of gravity is determined for the set of slices composing the volume. The deviation of the gravity center is an estimation of the coherence between the slices and is used to find out slices with certain displacement. Validation was performed with distorted real images where a slice is artificially misaligned with respect to set of slices. The displaced slice is found with a Recall of 84% and F Score of 68%.
Patient Education Leads to Better Care for Heart Patients.
ERIC Educational Resources Information Center
Rosenberg, Stanley G.
The staff of a heart and circulatory disease program of a State department of health conducted a special project at a city hospital which showed that a well-organized treatment and education program for patients with congestive heart failure increased the patient's knowledge of his disease, medication, and diet as well as his adherence to a…
Perspectives of Puerto Rican Adults about Heart Health and a Potential Community Program
ERIC Educational Resources Information Center
Todorova, Irina L. G.; Tejada, Shirley; Castaneda-Sceppa, Carmen
2014-01-01
Background: Puerto Ricans are the second largest Hispanic group in the United States, and older adults have significant health disparities. Educational programs that address heart disease risk for this population have rarely been developed and implemented. Purpose: To address this gap, the Heart Healthy Initiative for Puerto Rican adults is being…
Marshall, Thomas; Champagne-Langabeer, Tiffiany; Castelli, Darla; Hoelscher, Deanna
2017-12-01
To present research models based on artificial intelligence and discuss the concept of cognitive computing and eScience as disruptive factors in health and life science research methodologies. The paper identifies big data as a catalyst to innovation and the development of artificial intelligence, presents a framework for computer-supported human problem solving and describes a transformation of research support models. This framework includes traditional computer support; federated cognition using machine learning and cognitive agents to augment human intelligence; and a semi-autonomous/autonomous cognitive model, based on deep machine learning, which supports eScience. The paper provides a forward view of the impact of artificial intelligence on our human-computer support and research methods in health and life science research. By augmenting or amplifying human task performance with artificial intelligence, cognitive computing and eScience research models are discussed as novel and innovative systems for developing more effective adaptive obesity intervention programs.
Artificial Leaf Based on Artificial Photosynthesis for Solar Fuel Production
2017-06-30
AFRL-AFOSR-JP-TR-2017-0054 Artificial Leaf Based on Artificial Photosynthesis for Solar Fuel Production Mamoru Nango NAGOYA INSTITUTE OF TECHNOLOGY...for Solar Fuel Production 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA2386-14-1-4015 5c. PROGRAM ELEMENT NUMBER 61102F 6. AUTHOR(S) Mamoru Nango 5d...density immobilization of the photoreactants in the nanocavity inside PGP. The maximum production efficiency of formic acid inside the nanocavity was
How to teach artificial organs.
Zapanta, Conrad M; Borovetz, Harvey S; Lysaght, Michael J; Manning, Keefe B
2011-01-01
Artificial organs education is often an overlooked field for many bioengineering and biomedical engineering students. The purpose of this article is to describe three different approaches to teaching artificial organs. This article can serve as a reference for those who wish to offer a similar course at their own institutions or incorporate these ideas into existing courses. Artificial organ classes typically fulfill several ABET (Accreditation Board for Engineering and Technology) criteria, including those specific to bioengineering and biomedical engineering programs.
Artificial Neural Network Analysis System
2001-02-27
Contract No. DASG60-00-M-0201 Purchase request no.: Foot in the Door-01 Title Name: Artificial Neural Network Analysis System Company: Atlantic... Artificial Neural Network Analysis System 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Powell, Bruce C 5d. PROJECT NUMBER 5e. TASK NUMBER...34) 27-02-2001 Report Type N/A Dates Covered (from... to) ("DD MON YYYY") 28-10-2000 27-02-2001 Title and Subtitle Artificial Neural Network Analysis
Finding Edges and Lines in Images.
1983-06-01
34 UNCLASSI FlED , SECURITY CLASSIFICATION OF THIS PAGE ("osen Data Entered) READ INSTRUCTIONSREPORT DOCUMENTATION PAGE BEFORE COMPLETING FORM I. REPORT...PERFORMING ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK Artificial Intelligence Laboratory AREA&WORKUNITNUMBERS 545 Technology Square...in the Artificial Intelligence Laboratory of the Massachusetts Institute of Technology. Support for the laboratory’s artificial intelligence research
Heart to Heart Art: Empowering Homeless Children and Youth
ERIC Educational Resources Information Center
Shepard, Jerri; Booth, Deborah
2009-01-01
This article describes Heart to Heart Art, an after-school program developed for homeless children and youth at the YWCA in Spokane, Washington. Pre-service teacher candidates from a local university create meaningful activities that engage homeless students in visual art, music, drama, cooking, and community service. Heart to Heart Art was…
ERIC Educational Resources Information Center
Smith, Richard J.; Sauer, Mardelle A.
This guide is intended to assist teachers in using computer-aided design (CAD) workstations and artificial intelligence software to teach basic drafting skills. The guide outlines a 7-unit shell program that may also be used as a generic authoring system capable of supporting computer-based training (CBT) in other subject areas. The first section…
Knowledge Based Consultation for Finite Element Structural Analysis.
1980-05-01
Intelligence Finite Element Program Tutorial 20 ABSTRACT (Continue. on rees side If necessary and ide.n’ty b,’ bit,, k nionh.) In recent years, techniques of...involved in Artificial Intelligence at Stanford University developed the program MYCIN F2], for clinical consultation of diseases that require...and Rules The basic backward chaining logic, characteristic to Artificial Intelligence . approaching 1he problem of knowledge representation was
NASA Astrophysics Data System (ADS)
Stępak, Bogusz; Dzienny, Paulina; Franke, Volker; Kunicki, Piotr; Gotszalk, Teodor; Antończak, Arkadiusz
2018-04-01
Laser-induced periodic surface structures (LIPSS) are highly periodic wavy surface features which are frequently smaller than incident light wavelength that bring possibility of nanostructuring of many materials. In this paper the possibility of using them to homogeneously structure the surface of artificial heart valve made of PyC was examined. By changing laser irradiation parameters such like energy density and pulse separation the most suitable conditions were established for 1030 nm wavelength. A wide spectrum of periodicities and geometries was obtained. Interesting side effects like creating a thin shell-like layer were observed. Modified surfaces were examined using EDX and Raman spectroscopy to determine change in elemental composition of surface.
EPA Healthy Heart Program Webinar
EPA is raising awareness of heart disease and its link to air pollution and other environmental factors as a partner in the Million Hearts, a national initiative to prevent 1 million heart attacks and strokes by 2017.
Bibliography: Artificial Intelligence.
ERIC Educational Resources Information Center
Smith, Richard L.
1986-01-01
Annotates reference material on artificial intelligence, mostly at an introductory level, with applications to education and learning. Topics include: (1) programing languages; (2) expert systems; (3) language instruction; (4) tutoring systems; and (5) problem solving and reasoning. (JM)
Application Of Artificial Intelligence To Wind Tunnels
NASA Technical Reports Server (NTRS)
Lo, Ching F.; Steinle, Frank W., Jr.
1989-01-01
Report discusses potential use of artificial-intelligence systems to manage wind-tunnel test facilities at Ames Research Center. One of goals of program to obtain experimental data of better quality and otherwise generally increase productivity of facilities. Another goal to increase efficiency and expertise of current personnel and to retain expertise of former personnel. Third goal to increase effectiveness of management through more efficient use of accumulated data. System used to improve schedules of operation and maintenance of tunnels and other equipment, assignment of personnel, distribution of electrical power, and analysis of costs and productivity. Several commercial artificial-intelligence computer programs discussed as possible candidates for use.
NASA Astrophysics Data System (ADS)
Agrawal, Narendra Kumar; Sharma, Tamanna Kumari; Chauhan, Manish; Agarwal, Ravi; Vijay, Y. K.; Swami, K. C.
2016-05-01
Biomaterials are nonviable material used in medical devices, intended to interact with biological systems, which are becoming necessary for the development of artificial material for biological systems such as artificial skin diaphragm, valves for heart and kidney, lenses for eye etc. Polymers having novel properties like antibacterial, antimicrobial, high adhesion, blood compatibility and wettability are most suitable for synthesis of biomaterial, but all of these properties does not exist in any natural or artificial polymeric material. Nano particles and plasma treatment can offer these properties to the polymers. Hence a new nano-biomaterial has been developed by modifying the surface and chemical properties of Ag nanocomposite polymer membranes (NCPM) by Argon ion plasma treatment. These membranes were characterized using different techniques for surface and chemical modifications occurred. Bacterial adhesion and wettability were also tested for these membranes, to show direct use of this new class of nano-biomaterial for biomedical applications.
Design and construction of the artificial patient module for testing bioimpedance measuring devices
NASA Astrophysics Data System (ADS)
Młyńczak, Marcel; Pariaszewska, Katarzyna; Niewiadomski, Wiktor; Cybulski, Gerard
2013-10-01
The purpose of this study was to describe the design of the electronic module for testing bioimpedance measuring devices, for example impedance cardiographs or impedance pneumographs. Artificial Patient was conceived as an electronic equivalent of the impedance of skin-electrode interface and the impedance between electrodes - measured one. Different approaches in imitating a resistance of skin and an impedance of electrode-skin connection were presented. The module was adapted for frequently applied tetrapolar electrode configuration. Therefore the design do not enclose the elements simulating impedance between skin and receiver electrodes due to negligible effect of this impedance on the current flow through the receiver. The Artificial Patient enables testing either application generators, or receiver parts, particularly the level of noise and distortions of the signal. Use of digitally controlled potentiometer allows simulating different tissue resistances changes such as constant values, very-low-frequency and low-frequency changes corresponding to those caused by breathing or heart activity. Also it allows distorting signals in order to test algorithms of artifacts attenuation.
Reed, Shelby D.; Neilson, Matthew P.; Gardner, Matthew; Li, Yanhong; Briggs, Andrew H.; Polsky, Daniel E.; Graham, Felicia L.; Bowers, Margaret T.; Paul, Sara C.; Granger, Bradi B.; Schulman, Kevin A.; Whellan, David J.; Riegel, Barbara; Levy, Wayne C.
2015-01-01
Background Heart failure disease management programs can influence medical resource use and quality-adjusted survival. Because projecting long-term costs and survival is challenging, a consistent and valid approach to extrapolating short-term outcomes would be valuable. Methods We developed the Tools for Economic Analysis of Patient Management Interventions in Heart Failure (TEAM-HF) Cost-Effectiveness Model, a Web-based simulation tool designed to integrate data on demographic, clinical, and laboratory characteristics, use of evidence-based medications, and costs to generate predicted outcomes. Survival projections are based on a modified Seattle Heart Failure Model (SHFM). Projections of resource use and quality of life are modeled using relationships with time-varying SHFM scores. The model can be used to evaluate parallel-group and single-cohort designs and hypothetical programs. Simulations consist of 10,000 pairs of virtual cohorts used to generate estimates of resource use, costs, survival, and incremental cost-effectiveness ratios from user inputs. Results The model demonstrated acceptable internal and external validity in replicating resource use, costs, and survival estimates from 3 clinical trials. Simulations to evaluate the cost-effectiveness of heart failure disease management programs across 3 scenarios demonstrate how the model can be used to design a program in which short-term improvements in functioning and use of evidence-based treatments are sufficient to demonstrate good long-term value to the health care system. Conclusion The TEAM-HF Cost-Effectiveness Model provides researchers and providers with a tool for conducting long-term cost-effectiveness analyses of disease management programs in heart failure. PMID:26542504
Cost effectiveness of a smoking cessation program in patients admitted for coronary heart disease.
Quist-Paulsen, Petter; Lydersen, Stian; Bakke, Per S; Gallefoss, Frode
2006-04-01
Smoking cessation is probably the most important action to reduce mortality after a coronary event. Smoking cessation programs are not widely implemented in patients with coronary heart disease, however, possibly because they are thought not to be worth their costs. Our objectives were to estimate the cost effectiveness of a smoking cessation program, and to compare it with other treatment modalities in cardiovascular medicine. A cost-effectiveness analysis was performed on the basis of a recently conducted randomized smoking cessation intervention trial in patients admitted for coronary heart disease. The cost per life year gained by the smoking cessation program was derived from the resources necessary to implement the program, the number needed to treat to get one additional quitter from the program, and the years of life gained if quitting smoking. The cost effectiveness was estimated in a low-risk group (i.e. patients with stable coronary heart disease) and a high-risk group (i.e. patients after myocardial infarction or unstable angina), using survival data from previously published investigations, and with life-time extrapolation of the survival curves by survival function modeling. In a lifetime perspective, the incremental cost per year of life gained by the smoking cessation program was euro 280 and euro 110 in the low and high-risk group, respectively (2000 prices). These costs compare favorably to other treatment modalities in patients with coronary heart disease, being approximately 1/25 the cost of both statins in the low-risk group and angiotensin-converting enzyme inhibitors in the high-risk group. In a sensitivity analysis, the costs remained low in a wide range of assumptions. A nurse-led smoking cessation program with several months of intervention is very cost-effective compared with other treatment modalities in patients with coronary heart disease.
Lee, Sunhee; Lee, Junga; Choi, Jae Young
2017-04-01
Adolescents with congenital heart disease need to increase their resilience in the face of challenges in order to preserve their health and quality of life. This study aimed to develop a resilience improvement program for adolescents with congenital heart disease and also to evaluate any change in resilience and quality of life as a measure of the effectiveness of the resilience improvement programs. A nonequivalent control group pretest-posttest study was designed. Twenty-five adolescents who attended the first resilience improvement program were included in the experimental group, and 31 adolescents who took part in the second program were placed in the control group. Adolescents with congenital heart disease completed a self-report questionnaire on three separate occasions: the pretest, the first posttest and the second posttest. The self-report questionnaire included general characteristics and instruments to measure resilience and quality of life. For the longitudinal analysis, generalized estimating equations were used to evaluate the difference in the estimated average trajectories of resilience and quality of life changes. Independent predictors of resilience improvement in adolescents with congenital heart disease were the experimental group ( p=0.02) and middle and high school students ( p=0.02). Quality of life was not associated with membership in the experimental group. However, males scored higher than females on quality of life measures ( p=0.02). It is essential for healthcare providers to apply various programs, including those targeted at accepting illness, improving autonomy and independently managing disease, to adolescents with congenital heart disease.
In Pursuit of Educational Justice and Liberated Hearts
ERIC Educational Resources Information Center
Mirci, Philip S.
2008-01-01
This article contributes to a discussion about educational leadership programs related to social justice and diversity. It focuses on the development of social justice leaders through a doctoral program that culminates in a Doctorate in Educational Justice. The program's design is intended to empower graduates to act with hearts liberated through…
Chorna, Olena; Baldwin, H Scott; Neumaier, Jamie; Gogliotti, Shirley; Powers, Deborah; Mouvery, Amanda; Bichell, David; Maitre, Nathalie L
2016-07-01
Infants with complex congenital heart disease are at high risk for poor neurodevelopmental outcomes. However, implementation of dedicated congenital heart disease follow-up programs presents important infrastructure, personnel, and resource challenges. We present the development, implementation, and retrospective review of 1- and 2-year outcomes of a Complex Congenital Heart Defect Neurodevelopmental Follow-Up program. This program was a synergistic approach between the Pediatric Cardiology, Cardiothoracic Surgery, Pediatric Intensive Care, and Neonatal Intensive Care Unit Follow-Up teams to provide a feasible and responsible utilization of existing infrastructure and personnel, to develop and implement a program dedicated to children with congenital heart disease. Trained developmental testers administered the Ages and Stages Questionnaire-3 over the phone to the parents of all referred children at least once between 6 and 12 months' corrected age. At 18 months' corrected age, all children were scheduled in the Neonatal Intensive-Care Unit Follow-Up Clinic for a visit with standardized neurological exams, Bayley III, multidisciplinary therapy evaluations and continued follow-up. Of the 132 patients identified in the Cardiothoracic Surgery database and at discharge from the hospital, a total number of 106 infants were reviewed. A genetic syndrome was identified in 23.4% of the population. Neuroimaging abnormalities were identified in 21.7% of the cohort with 12.8% having visibly severe insults. As a result, 23 (26.7%) received first-time referrals for early intervention services, 16 (13.8%) received referrals for new services in addition to their existing ones. We concluded that utilization of existing resources in collaboration with established programs can ensure targeted neurodevelopmental follow-up for all children with complex congenital heart disease. © 2016 American Heart Association, Inc.
Fonarow, Gregg C; Calitz, Chris; Arena, Ross; Baase, Catherine; Isaac, Fikry W; Lloyd-Jones, Donald; Peterson, Eric D; Pronk, Nico; Sanchez, Eduardo; Terry, Paul E; Volpp, Kevin G; Antman, Elliott M
2015-05-19
The workplace is an important setting for promoting cardiovascular health and cardiovascular disease and stroke prevention in the United States. Well-designed, comprehensive workplace wellness programs have the potential to improve cardiovascular health and to reduce mortality, morbidity, and disability resulting from cardiovascular disease and stroke. Nevertheless, widespread implementation of comprehensive workplace wellness programs is lacking, and program composition and quality vary. Several organizations provide worksite wellness recognition programs; however, there is variation in recognition criteria, and they do not specifically focus on cardiovascular disease and stroke prevention. Although there is limited evidence to suggest that company performance on employer health management scorecards is associated with favorable healthcare cost trends, these data are not currently robust, and further evaluation is needed. As a recognized national leader in evidence-based guidelines, care systems, and quality programs, the American Heart Association/American Stroke Association is uniquely positioned and committed to promoting the adoption of comprehensive workplace wellness programs, as well as improving program quality and workforce health outcomes. As part of its commitment to improve the cardiovascular health of all Americans, the American Heart Association/American Stroke Association will promote science-based best practices for comprehensive workplace wellness programs and establish benchmarks for a national workplace wellness recognition program to assist employers in applying the best systems and strategies for optimal programming. The recognition program will integrate identification of a workplace culture of health and achievement of rigorous standards for cardiovascular health based on Life's Simple 7 metrics. In addition, the American Heart Association/American Stroke Association will develop resources that assist employers in meeting these rigorous standards, facilitating access to high-quality comprehensive workplace wellness programs for both employees and dependents, and fostering innovation and additional research. © 2015 American Heart Association, Inc.
Computing Visible-Surface Representations,
1985-03-01
Terzopoulos N00014-75-C-0643 9. PERFORMING ORGANIZATION NAME AMC ADDRESS 10. PROGRAM ELEMENT. PROJECT, TASK Artificial Inteligence Laboratory AREA A...Massachusetts Institute of lechnolog,. Support lbr the laboratory’s Artificial Intelligence research is provided in part by the Advanced Rtccarcl Proj...dynamically maintaining visible surface representations. Whether the intention is to model human vision or to design competent artificial vision systems
Artificial Intelligence and Its Potential as an Aid to Vocational Training and Education.
ERIC Educational Resources Information Center
Aleksander, I.; And Others
This document contains a series of papers which attempt to de-mystify the subject of artificial intelligence and to show how some countries in the European Community (EC) are approaching the promotion of development and application of artificial intelligence systems that can be used as an aid in vocational training programs, as well as to…
A Memory-Process Model of Symbolic Assimilation
1974-04-01
Systems: Final Report of a Study Group, published for Artificial Intellegence by North-Holland/Amorican...contribution of the methods is answered by evaluating the same program in the context of the field of artificial intelligence. The remainder of the...been widely demonstrated on a diversity of tasks in tha history of artificial intelligence. See [r.71], chapter 2. Given a particular task to be
Bartoli, Carlo R.; Dowling, Robert D.
2011-01-01
Synopsis The recent, widespread success of mechanical circulatory support has ushered in a new era of cardiovascular medicine in which numerous implantable devices exist to treat advanced heart failure. As cardiac assist devices gain prevalence in the clinical management of cardiovascular disease, it is increasingly important to raise awareness of novel device systems, the unique mechanisms by which they function, and implications for patient management. In this article, we present state-of-the-art devices that are currently under development or in clinical trials. Devices are categorized as Standard Full-Support (HeartMate III, CorAide, Evaheart LVAS), Less-Invasive Full-Support (MVAD), Partial-Support (CircuLite Synergy Pocket Micro-Pump, Reitan Catheter Pump, Procyrion CAD, C-Pulse, Symphony Counterpulsation Device) Right Ventricular Assist Device (RVAD; DexAide, Impella RD Recover, Impella RP), and Total Artificial Heart (TAH; CardioWest, AbioCor II, Continuous-Flow TAH, Continuous-Flow BiVAD). Implantation strategy, mechanism of action, durability, efficacy, hemocompatibility, and human factors such as quality of life during device support are considered. The feasibility of novel strategies for unloading the failing heart is examined. PMID:22062206
Optimum Heart Rate to Minimize Pulsatile External Cardiac Power
NASA Astrophysics Data System (ADS)
Pahlevan, Niema; Gharib, Morteza
2011-11-01
The workload on the left ventricle is composed of steady and pulsatile components. Clinical investigations have confirmed that an abnormal pulsatile load plays an important role in the pathogenesis of left ventricular hypertrophy (LVH) and progression of LVH to congestive heart failure (CHF). The pulsatile load is the result of the complex dynamics of wave propagation and reflection in the compliant arterial vasculature. We hypothesize that aortic waves can be optimized to reduce the left ventricular (LV) pulsatile load. We used an in-vitro experimental approach to investigate our hypothesis. A unique hydraulic model was used for in-vitro experiments. This model has physical and dynamical properties similar to the heart-aorta system. Different compliant models of the artificial aorta were used to test the hypothesis under various aortic rigidities. Our results indicate that: i) there is an optimum heart rate that minimizes LV pulsatile power (this is in agreement with our previous computational study); ii) introducing an extra reflection site at the specific location along the aorta creates constructive wave conditions that reduce the LV pulsatile power.
Experience with the SynCardia total artificial heart in a Canadian centre
Nguyen, Anthony; Pellerin, Michel; Perrault, Louis P.; White, Michel; Ducharme, Anique; Racine, Normand; Carrier, Michel
2017-01-01
Background The SynCardia total artificial heart (TAH) provides complete circulatory support by replacing both native ventricles. Accepted indications include bridge to transplantation and destination therapy. We review our experience with TAH implantation during a period when axial flow pump became available. Methods We retrospectively analyzed the demographics, clinical characteristics and survival of all patients receiving the TAH. Results From September 2004 to November 2016, 13 patients (12 men, mean age 45 ± 13 yr) received the TAH for refractory cardiogenic shock secondary to idiopathic (56%) or ischemic (17%) cardiomyopathy and to other various causes (33%). Before implantation, mean ejection fraction was 14% ± 4%, 7 (54%) patients had previous cardiac surgery, 4 (31%) were on mechanical ventilation, and 3 (23%) patients were on dialysis. The mean duration of TAH support was 46 ± 40 days. Three (23%) patients died while on support after a mean of 15 days. Actuarial survival on support was 77% ± 12% at 30 days after implantation. Complications on support included stroke (n = 1, 8%), acute respiratory distress syndrome requiring prolonged intubation (n = 5, 38%) and acute renal failure requiring temporary dialysis (n = 5, 38%). Ten (77%) patients survived to be transplanted after a mean of 52 ± 42 days of support. Actuarial survival rates after transplant were 67% ± 16% at 1 month and 56% ± 17% at 1 year after transplantation. Conclusion The TAH provides an alternative with low incidence of neurologic events in extremely fragile and complex patients waiting for heart transplantation. Complex and unusual anatomic conditions explained the current use of TAH. PMID:28930049
Experience with the SynCardia total artificial heart in a Canadian centre.
Nguyen, Anthony; Pellerin, Michel; Perrault, Louis P; White, Michel; Ducharme, Anique; Racine, Normand; Carrier, Michel
2017-12-01
The SynCardia total artificial heart (TAH) provides complete circulatory support by replacing both native ventricles. Accepted indications include bridge to transplantation and destination therapy. We review our experience with TAH implantation during a period when axial flow pump became available. We retrospectively analyzed the demographics, clinical characteristics and survival of all patients receiving the TAH. From September 2004 to November 2016, 13 patients (12 men, mean age 45 ± 13 yr) received the TAH for refractory cardiogenic shock secondary to idiopathic (56%) or ischemic (17%) cardiomyopathy and to other various causes (33%). Before implantation, mean ejection fraction was 14% ± 4%, 7 (54%) patients had previous cardiac surgery, 4 (31%) were on mechanical ventilation, and 3 (23%) patients were on dialysis. The mean duration of TAH support was 46 ± 40 days. Three (23%) patients died while on support after a mean of 15 days. Actuarial survival on support was 77% ± 12% at 30 days after implantation. Complications on support included stroke ( n = 1, 8%), acute respiratory distress syndrome requiring prolonged intubation ( n = 5, 38%) and acute renal failure requiring temporary dialysis ( n = 5, 38%). Ten (77%) patients survived to be transplanted after a mean of 52 ± 42 days of support. Actuarial survival rates after transplant were 67% ± 16% at 1 month and 56% ± 17% at 1 year after transplantation. The TAH provides an alternative with low incidence of neurologic events in extremely fragile and complex patients waiting for heart transplantation. Complex and unusual anatomic conditions explained the current use of TAH.
Software Reviews. PC Software for Artificial Intelligence Applications.
ERIC Educational Resources Information Center
Epp, Helmut; And Others
1988-01-01
Contrasts artificial intelligence and conventional programming languages. Reviews Personal Consultant Plus, Smalltalk/V, and Nexpert Object, which are PC-based products inspired by problem-solving paradigms. Provides information on background and operation of each. (RT)
[Animal experimentation, computer simulation and surgical research].
Carpentier, Alain
2009-11-01
We live in a digital world In medicine, computers are providing new tools for data collection, imaging, and treatment. During research and development of complex technologies and devices such as artificial hearts, computer simulation can provide more reliable information than experimentation on large animals. In these specific settings, animal experimentation should serve more to validate computer models of complex devices than to demonstrate their reliability.
Years after Inventors Die, Royalties Are Pennies from Heaven
ERIC Educational Resources Information Center
Blumenstyk, Goldie
2009-01-01
Sarah L. Kieweg had her own nice surprise when the University of Central Florida contacted her. She understood quite a bit about her father's pioneering work on artificial intelligence in the 1990s. Still, in 2006, eight years after he died of a heart attack, at age 50, the call from the university came out of the blue: some of James R. Driscoll's…
NASA Technical Reports Server (NTRS)
1985-01-01
Thermionic energy conversion is the production of energy from a nuclear source. It is a technology advanced by SNSO, a joint research and development organization formed by NASA and the AEC. SNSO contracted with Thermo Electron Corporation to develop high temperature applications, i.e., metals with high melting points. Thermo Electron Corporation's expertise resulted in contracts for products made from exotic metals such as bone implants, artificial hips, and heart pacemakers.
NASA Astrophysics Data System (ADS)
Iwase, Satoshi; Sugenoya, Junichi; Sato, Maki; Shimizu, Yuuki; Kanikowska, Dominika; Nishimura, Nooki; Takada, Hiroki; Takada, Masumi; Mano, Tadaki; Ishida, Koji; Akima, Hiroshi; Katayama, Keisho; Hirayanagi, Kaname; Shiozawa, Tomoki; Yajima, Katzuyoshi; Watanabe, Yoriko; Suzuki, Satomi; Fukunnaga, Tetsuo; Masuo, Yoshihisa
2008-06-01
Effectiveness of centrifuge-induced artificial gravity and ergometric exercise as a countermeasure to space deconditioning, including cardiovascular deconditioning, myatrophy, and osteoporosis, induced by 20 days of head-down bedrest., was examined in 12 healthy men in 2006, and 8 healthy men in 2007. Bedrest was performed with 2300 kcal of diet. Water intake was recommended more than the urine volume in a previous day. A new protocol for artificial gravity with ergometric exercise was adopted, with 1.6 G of artificial gravity at heart level and 60 W of exercise every day in 2006, and every other day in 2007. The load was suspended when subjects complained all-out, and was continued until 30 min cumulative total load time. Gravity was stepped up by 0.2 G or exercise load was stepped up by 15 W alternately when the subject endured the load for 5 min. Gravity tolerance was examined by using centrifuge, and anti-G score was determined before and after the bedrest. Not all result has been analyzed, however, effectiveness of artificial gravity with ergometric exercise was evidenced in orthostatic tolerance, physical fitness, cardiac function, myatrophy, and bone metabolism in everyday protocol, but not in every other day protocol. We concluded this everyday protocol was effective in cardiovascular deconditioning myatrophy, and bone metabolism.
Lakdizaji, Sima; Hassankhni, Hadi; Mohajjel Agdam, Alireza; Khajegodary, Mohammad; Salehi, Rezvanieh
2013-03-01
Heart failure is one of the most common cardiovascular diseases which decrease the quality of life. Most of the factors influencing the quality of life can be modified with educational interventions. Therefore, this study examined the impact of a continuous training program on quality of life of patients with heart failure. This randomized clinical trial study was conducted during May to August 2011. Forty four participants with heart failure referred to Shahid Madani's polyclinics of Tabriz were selected through convenient sampling method and were randomly allocated to two groups. The intervention group (n = 22) received ongoing training including one-to-one teaching, counseling sessions and phone calls over 3 months. The control group (n = 22) received routine care program. Data on quality of life was collected using the Minnesota Living with Heart Failure Questionnaire at baseline as well as three months later. The statistical tests showed significant differences in the physical, emotional dimensions and total quality of life in intervention group. But in control group, no significant differences were obtained. There was not any significant association in demographic characteristics and quality of life. Ongoing training programs can be effective in improving quality of life of patients with heart failure. Hence applying ongoing educational program as a non-pharmacological intervention can help to improve the quality of life of these patients.
[Heart transplant in "Nuevo Leon": the first 33 cases].
Herrera Garza, Eduardo; Molina Gamboa, Julio; Decanini Arcaute, Horacio; Ibarra Flores, Marcos; Torres García, Myrella; Macías Hidalgo, Carlos; González Oviedo, Roberto; de la Fuente Magallanes, Felipe de Jesús; Elizondo Sifuentes, Lius Angel; Villarreal Arredondo, Miguel Angel; Ortega Durán, Oscar; Martínez Bermúdez, Pedro; García Castillo, Armando; Becerra García, Oralia; Martínez Rodríguez, Diana; Contreras Lara, Carmen; Olivares de la Cerda, María de Consuelo; Treviño Treviño, Alfonso
2006-01-01
Heart failure is one of the most important causes of death worldwide. Heart transplant is the last effective alternative when the medical and surgical treatments have failed in patients with end stage heart failure, giving them an 80% one year survival rate. Unfortunately, during the outcome, the heart transplant patients can develop complications such as graft rejection and opportunistic infections because of the use of immunosuppressive therapy. In the present article we report the experience with 33 heart transplant patients. Our program not only has successfully transplanted patients with advanced age but, for the first time in Latin America we have transplanted patients assisted with the ambulatory Thoratec TLC II system. Even with limited resources, we have managed the same complications than other heart transplant programs, our 82% one year survival rate is similar than reports in medical literature.
Chamber identity programs drive early functional partitioning of the heart.
Mosimann, Christian; Panáková, Daniela; Werdich, Andreas A; Musso, Gabriel; Burger, Alexa; Lawson, Katy L; Carr, Logan A; Nevis, Kathleen R; Sabeh, M Khaled; Zhou, Yi; Davidson, Alan J; DiBiase, Anthony; Burns, Caroline E; Burns, C Geoffrey; MacRae, Calum A; Zon, Leonard I
2015-08-26
The vertebrate heart muscle (myocardium) develops from the first heart field (FHF) and expands by adding second heart field (SHF) cells. While both lineages exist already in teleosts, the primordial contributions of FHF and SHF to heart structure and function remain incompletely understood. Here we delineate the functional contribution of the FHF and SHF to the zebrafish heart using the cis-regulatory elements of the draculin (drl) gene. The drl reporters initially delineate the lateral plate mesoderm, including heart progenitors. Subsequent myocardial drl reporter expression restricts to FHF descendants. We harnessed this unique feature to uncover that loss of tbx5a and pitx2 affect relative FHF versus SHF contributions to the heart. High-resolution physiology reveals distinctive electrical properties of each heart field territory that define a functional boundary within the single zebrafish ventricle. Our data establish that the transcriptional program driving cardiac septation regulates physiologic ventricle partitioning, which successively provides mechanical advantages of sequential contraction.
The business concept of leader pricing as applied to heart failure disease management.
Hauptman, Paul J; Bednarek, Heather L
2004-01-01
The implementation of a disease management approach for patients with heart failure has been promoted as a way to improve outcomes, including a decrease in hospitalizations. However, in the absence of rigorous cost analyses and with revenues limited by professional fees, heart failure disease management programs may appear to operate at a loss. The literature outlining the importance of disease management for patients with heart failure is summarized. We review the limitations of current cost analyses and outline the economic concepts of leader pricing, vertical integration and transaction costs to argue that heart failure disease management programs may provide significant "downstream" revenue for an integrated system of health care delivery in a fee-for-service payment structure, while reducing overall costs of care. Pilot data from a university-based program are used in support of this argument. In addition, the favorable impact on patient satisfaction and loyalty can enhance market share, a vital consideration for all health systems. Options for improving the reputation of heart failure disease management within a health system are suggested. Viewed as a loss leader, disease management provides not only quality care for patients with heart failure but also appears to provide financial benefits to the health system that funds the infrastructure and administration of the program. The actual magnitude of this benefit and the degree to which it mitigates overall administration costs requires further study.
1999-10-01
Sciences A. Anatomy, physiology and pathophysiology 1. Cardiovascular a. Arrhythmias b. Ischemic heart disease/angina c. Myocardial infarction d...Hypertension e. Congestive Heart Failure f. Shock Instructional Methods 66 g. Valvular Heart disease h. Cardiomyopathy i. Peripheral vascular disease j...Pulmonary artery pressure monitoring Instructional Methods 71 3. Precordial/esophageal stethoscope /Doppler 4. Respiratory monitoring a. Apnea monitor b
McBride, Michael G; Binder, Tracy Jo; Paridon, Stephen M
2007-01-01
To determine the safety and feasibility of an inpatient exercise training program for a group of pediatric heart transplantation candidates on multiple inotropic support. Children with end-stage heart disease often require heart transplantation. Currently, no data exist on the safety and feasibility of an inpatient exercise training program in pediatric patients awaiting heart transplantation while on inotropic support. Twenty ambulatory patients (11 male; age, 13.6 +/- 3.2 years) were admitted, listed, and subsequently enrolled into an exercise training program while awaiting heart transplantation. Patient diagnoses consisted of dilated cardiomyopathy (n = 15), restrictive cardiomyopathy (n = 1), and failing single-ventricle physiology (n = 4). Inotropic support consisted of a combination of dobutamine, dopamine, or milrinone. Exercise sessions were scheduled three times a week lasting from 30 to 60 minutes and consisted of aerobic and musculoskeletal conditioning. Over 6.2 +/- 4.2 months, 1,251 of a possible 1,508 exercise training sessions were conducted, with a total of 615 hours (26.3 +/- 2.7 min/session) dedicated to low-intensity aerobic exercise. Reasons for noncompliance included a change in medical status, staffing, or patient cooperation. Two adverse episodes (seizures) occurred, neither of which resulted in termination from the program. No adverse episodes of hypotension or significant complex arrhythmias occurred. No complication of medication administration or loss of intravenous access occurred. Data from this study indicate that pediatric patients on inotropic support as a result of systemic ventricular or biventricular heart failure can safely participate in exercise training programs with relatively moderate to high compliance.
Third Conference on Artificial Intelligence for Space Applications, part 2
NASA Technical Reports Server (NTRS)
Denton, Judith S. (Compiler); Freeman, Michael S. (Compiler); Vereen, Mary (Compiler)
1988-01-01
Topics relative to the application of artificial intelligence to space operations are discussed. New technologies for space station automation, design data capture, computer vision, neural nets, automatic programming, and real time applications are discussed.
A review of European applications of artificial intelligence to space
NASA Technical Reports Server (NTRS)
Drummond, Mark (Editor); Stewart, Helen (Editor)
1993-01-01
The purpose is to describe the applications of Artificial Intelligence (AI) to the European Space program that are being developed or have been developed. The results of a study sponsored by the Artificial Intelligence Research and Development program of NASA's Office of Advanced Concepts and Technology (OACT) are described. The report is divided into two sections. The first consists of site reports, which are descriptions of the AI applications seen at each place visited. The second section consists of two summaries which synthesize the information in the site reports by organizing this information in two different ways. The first organizes the material in terms of the type of application, e.g., data analysis, planning and scheduling, and procedure management. The second organizes the material in terms of the component technologies of Artificial Intelligence which the applications used, e.g., knowledge based systems, model based reasoning, procedural reasoning, etc.
ERIC Educational Resources Information Center
Colchamiro, Rachel; Ghiringhelli, Kara; Hause, Judith
2010-01-01
The "Touching Hearts, Touching Minds" initiative was funded through a 2003 United States Department of Agriculture Special Projects grant to revitalize nutrition education and services in the Massachusetts Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) Program. The 30 nutrition education materials and…
USDA-ARS?s Scientific Manuscript database
This research is the first use of the Box-Jenkins time-series models to describe changes in heart rate (HR) of free-ranging crossbred cows (Bos taurus) receiving both programmed audio cues from directional virtual fencing (DVFTM) devices and non-programmed environmental/physiological cues. The DVFT...
42 CFR 52e.1 - To what programs do these regulations apply?
Code of Federal Regulations, 2010 CFR
2010-10-01
... HEART, LUNG, AND BLOOD INSTITUTE GRANTS FOR PREVENTION AND CONTROL PROJECTS § 52e.1 To what programs do... the prevention and control of heart, blood vessel, lung, and blood diseases, with special...
42 CFR 52e.1 - To what programs do these regulations apply?
Code of Federal Regulations, 2011 CFR
2011-10-01
... HEART, LUNG, AND BLOOD INSTITUTE GRANTS FOR PREVENTION AND CONTROL PROJECTS § 52e.1 To what programs do... the prevention and control of heart, blood vessel, lung, and blood diseases, with special...
42 CFR 52e.1 - To what programs do these regulations apply?
Code of Federal Regulations, 2013 CFR
2013-10-01
... HEART, LUNG, AND BLOOD INSTITUTE GRANTS FOR PREVENTION AND CONTROL PROJECTS § 52e.1 To what programs do... the prevention and control of heart, blood vessel, lung, and blood diseases, with special...
42 CFR 52e.1 - To what programs do these regulations apply?
Code of Federal Regulations, 2014 CFR
2014-10-01
... HEART, LUNG, AND BLOOD INSTITUTE GRANTS FOR PREVENTION AND CONTROL PROJECTS § 52e.1 To what programs do... the prevention and control of heart, blood vessel, lung, and blood diseases, with special...
42 CFR 52e.1 - To what programs do these regulations apply?
Code of Federal Regulations, 2012 CFR
2012-10-01
... HEART, LUNG, AND BLOOD INSTITUTE GRANTS FOR PREVENTION AND CONTROL PROJECTS § 52e.1 To what programs do... the prevention and control of heart, blood vessel, lung, and blood diseases, with special...
Athilingam, Ponrathi; Clochesy, John M; Labrador, Miguel A
2018-02-01
Heart failure is a complex syndrome among older adults who may experience and interpret symptoms differently. These differences in symptom interpretation may influence decision-making in symptom management. A well-informed and motivated person may develop the knowledge and skills needed to successfully manage symptoms. Therefore, the patient-centered mobile health application HeartMapp was designed to engage patients with heart failure in self-care management by offering tailored alerts and feedback using mobile phones. The main objective of this article is to describe the six-step intervention mapping approach including (1) the initial needs assessment, (2) proximal program objective, (3) selection of theory-based methods, (4) the translation of objectives into an actual program plan for mobile health intervention, (5) adaptation and implementation plan, and (6) evaluation plan that assisted the team in the development of a conceptual framework and intervention program matrix during the development of HeartMapp. The HeartMapp intervention takes the information, motivation, and behavioral skills model as the theoretical underpinning, with "patient engagement" as the key mediator in achieving targeted and persistent self-care behavioral changes in patients with heart failure. The HeartMapp intervention is proposed to improve self-care management and long-term outcomes.
ERIC Educational Resources Information Center
Finkenberg, Mel; And Others
The purpose of this study was to compare the coronary heart disease (CHD) probability estimates of a group of sedentary males involved in an exercise stress test program from 1968 through 1974 with those of a comparison group of sedentary males not involved in the program. The program was designed to evaluate cardiopulmonary function and improve…
A PKM2 signature in the failing heart
Rees, Meredith L.; Subramaniam, Janani; Li, Yuanteng; Hamilton, Dale J.; Frazier, O. Howard; Taegtmeyer, Heinrich
2015-01-01
A salient feature of the failing heart is metabolic remodeling towards predominant glucose metabolism and activation of the fetal gene program. Sunitinib is a multitargeted receptor tyrosine kinase inhibitor used for the treatment of highly vascularized tumors. In diabetic patients, sunitinib significantly decreases blood glucose. However, a considerable proportion of sunitinib-treated patients develop cardiac dysfunction or failure. We asked whether sunitinib treatment results in shift towards glycolysis in the heart. Glucose uptake by the heart was increased fivefold in mice treated with sunitinib. Transcript analysis by qPCR revealed an induction of genes associated with glycolysis and reactivation of the fetal gene program. Additionally, we observed a shift in the enzyme pyruvate kinase from the adult M1 (PKM1) isoform to the fetal M2 (PKM2) isoform, a hallmark of the Warburg Effect. This novel observation led us to examine whether a similar shift occurs in human heart failure. Examination of tissue from patients with heart failure similarly displayed an induction of PKM2. Moreover, this phenomenon was partially reversed following mechanical unloading. We propose that pyruvate kinase isoform switching represents a novel feature of the fetal gene program in the failing heart. PMID:25735978
Cardiogenic shock. Current concepts in management.
Balakumaran, K; Hugenholtz, P G
1986-10-01
This article presents a categorisation of circulatory shock and discusses the causes, haemodynamics, and clinical recognition of cardiogenic shock. The first step in the management strategy in cardiogenic shock is to guide the patient from the state of shock to one of managed haemodynamic stability. The therapeutic manoeuvres of this first step constitute the management tactics, which can be grouped under 3 general headings: (a) making the most of a malfunctioning heart; (b) improving the state of the heart; and (c) reducing the demands on the heart. In order to make the most of the heart, i.e. to get the highest possible output at the lowest possible cost, clinicians need to use their judgement in stimulating an overtaxed heart on the one hand, and in manipulating the loads on it (the preload and afterload) on the other, for although these methods may be advantageous, they are not without their pitfalls. Efforts to improve the state of the heart often necessitate surgical (e.g. mitral valve replacement) or semisurgical (e.g. coronary angiography and recanalisation) techniques, although intravenous antithrombotic agents may achieve comparable results in a few cases at the bedside. Reducing the demands on the heart is an active process involving the takeover of at least a part of the work of the heart by ancillary devices such as the intra-aortic balloon pump, and of the work of breathing by intubation and artificial ventilation. The individuality of each case of cardiogenic shock emphasises the need for empirical modulation of therapy based on feedback information obtained by haemodynamic monitoring.
Robotic air vehicle. Blending artificial intelligence with conventional software
NASA Technical Reports Server (NTRS)
Mcnulty, Christa; Graham, Joyce; Roewer, Paul
1987-01-01
The Robotic Air Vehicle (RAV) system is described. The program's objectives were to design, implement, and demonstrate cooperating expert systems for piloting robotic air vehicles. The development of this system merges conventional programming used in passive navigation with Artificial Intelligence techniques such as voice recognition, spatial reasoning, and expert systems. The individual components of the RAV system are discussed as well as their interactions with each other and how they operate as a system.
An Interactive Artificial Cutting Plane Method for Bicriterion Integer Programming Problems
1992-08-01
AUTHOR(S) Diane Breivik Allen, 1st Lt 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER AFIT Student Attending...INTERACTIVE ARTIFICIAL CUTTING PLANE METHOD FOR BICRITERION INTEGER PROGRAMMING PROBLEMS By Diane Breivik Allen A Thesis Submitted to the Faculty of...ITfiSRA&1 DTIC TAB 0 Unannounced 0 Justirication By BY Diane Breivik Allen Distributlon/ Availability CQdes Avail and/or Dist Special Approved: DTI
Defense Advanced Research Projects Agency Strategic Plan
2007-02-01
be able to feel objects that are being grasped so that the prosthesis is experienced as an arm instead of as a tool; and (iii) development of...instrument, but also the ability to sense an artificial limb’s position without looking at it, and to actually " feel " precisely what the artificial limb...is touching by relaying sensations through residual nerves. (This program is also leveraging developments in a core technology program, Human Assisted
Artificial intelligence: Learning to play Go from scratch
NASA Astrophysics Data System (ADS)
Singh, Satinder; Okun, Andy; Jackson, Andrew
2017-10-01
An artificial-intelligence program called AlphaGo Zero has mastered the game of Go without any human data or guidance. A computer scientist and two members of the American Go Association discuss the implications. See Article p.354
International Multidisciplinary Artificial Gravity (IMAG) Project
NASA Technical Reports Server (NTRS)
Laurini, Kathy
2007-01-01
This viewgraph presentation reviews the efforts of the International Multidisciplinary Artificial Gravity Project. Specifically it reviews the NASA Exploration Planning Status, NASA Exploration Roadmap, Status of Planning for the Moon, Mars Planning, Reference health maintenance scenario, and The Human Research Program.
Heidenreich, Paul A; Lewis, William R; LaBresh, Kenneth A; Schwamm, Lee H; Fonarow, Gregg C
2009-10-01
Many hospitals enrolled in the American Heart Association's Get With The Guidelines (GWTG) Program achieve high levels of recommended care for heart failure, acute myocardial infarction (MI) and stroke. However, it is unclear if outcomes are better in those hospitals recognized by the GWTG program for their processes of care. We compared hospitals enrolled in GWTG and receiving achievement awards for high levels of recommended processes of care with other hospitals using data on risk-adjusted 30-day survival for heart failure and acute MI reported by the Center for Medicare and Medicaid Services. Among the 3,909 hospitals with 30-day data reported by Center for Medicare and Medicaid Services 355 (9%) received GWTG achievement awards. Risk-adjusted mortality for hospitals receiving awards was lower for both heart failure (11.0% vs 11.2%, P = .0005) and acute MI (16.1% vs 16.5%, P < .0001) compared to those not receiving awards. After additional adjustment for hospital characteristics and noncardiac performance measures, the reduction in mortality remained significantly lower for GWTG award hospitals for acute myocardial infraction (-0.19%, 95% CI -0.33 to -0.05), but not for heart failure (-0.11%, 95% CI -0.25 to 0.02). Additional adjustment for cardiac processes of care reduced the benefit of award hospitals by 28% for heart failure mortality and 43% for acute MI mortality. Hospitals receiving achievement awards from the GWTG program have modestly lower risk adjusted mortality for acute MI and to a lesser extent, heart failure, explained in part by better process of care.
Duley, Aaron R; Janelle, Christopher M; Coombes, Stephen A
2004-11-01
The cardiovascular system has been extensively measured in a variety of research and clinical domains. Despite technological and methodological advances in cardiovascular science, the analysis and evaluation of phasic changes in heart rate persists as a way to assess numerous psychological concomitants. Some researchers, however, have pointed to constraints on data analysis when evaluating cardiac activity indexed by heart rate or heart period. Thus, an off-line application toolkit for heart rate analysis is presented. The program, written with National Instruments' LabVIEW, incorporates a variety of tools for off-line extraction and analysis of heart rate data. Current methods and issues concerning heart rate analysis are highlighted, and how the toolkit provides a flexible environment to ameliorate common problems that typically lead to trial rejection is discussed. Source code for this program may be downloaded from the Psychonomic Society Web archive at www.psychonomic.org/archive/.
Saadah, Loai M; Chedid, Fares D; Sohail, Muhammad R; Nazzal, Yazied M; Al Kaabi, Mohammed R; Rahmani, Aiman Y
2014-03-01
To identify subgroups of premature infants who may benefit from palivizumab prophylaxis during nosocomial outbreaks of respiratory syncytial virus (RSV) infection. Retrospective analysis using an artificial intelligence model. Level IIIB, 35-bed, neonatal intensive care unit (NICU) at a tertiary care hospital in the United Arab Emirates. One hundred seventy six premature infants, born at a gestational age of 22-34 weeks, and hospitalized during four RSV outbreaks that occurred between April 2005 and July 2007. We collected demographic and clinical data for each patient by using a standardized form. Input data consisted of seven categoric and continuous variables each. We trained, tested, and validated artificial neural networks for three outcomes of interest: mortality, days of supplemental oxygen, and length of NICU stay after the index case was identified. We compared variable impacts and performed reassignments with live predictions to evaluate the effect of palivizumab. Of the 176 infants, 31 (17.6%) received palivizumab during the outbreaks. All neural network configurations converged within 4 seconds in less than 400 training cycles. Infants who received palivizumab required supplemental oxygen for a shorter duration compared with controls (105.2 ± 7.2 days vs 113.2 ± 10.4 days, p=0.003). This benefit was statistically significant in male infants whose birth weight was less than 0.7 kg and who had hemodynamically significant congenital heart disease. Length of NICU stay after identification of the index case and mortality were independent of palivizumab use. Palivizumab may be an effective intervention during nosocomial outbreaks of RSV in a subgroup of extremely low-birth-weight male infants with hemodynamically significant congenital heart disease. © 2013 Pharmacotherapy Publications, Inc.
A transcutaneous energy transmission system for artificial heart adapting to changing impedance.
Fu, Yang; Hu, Liang; Ruan, Xiaodong; Fu, Xin
2015-04-01
This article presents a coil-coupling-based transcutaneous energy transmission system (TETS) for wirelessly powering an implanted artificial heart. Keeping high efficiency is especially important for TETS, which is usually difficult due to transmission impedance changes in practice, which are commonly caused by power requirement variation for different body movements and coil-couple malposition accompanying skin peristalsis. The TETS introduced in this article is designed based on a class-E power amplifier (E-PA), of which efficiency is over 95% when its load is kept in a certain range. A resonance matching and impedance compressing functions coupled network based on parallel-series capacitors is proposed in the design, to enhance the energy transmission efficiency and capacity of the coil-couple through resonating, and meanwhile compress the changing range of the transmission impedance to meet the load requirements of the E-PA and thus keep the high efficiency of TETS. An analytical model of the designed TETS is built to analyze the effect of the network and also provide bases for following parameters determination. Then, according algorithms are provided to determine the optimal parameters required in the TETS for good performance both in resonance matching and impedance compressing. The design is tested by a series of experiments, which validate that the TETS can transmit a wide range of power with a total efficiency of at least 70% and commonly beyond 80%, even when the coil-couple is seriously malpositioned. The design methodology proposed in this article can be applied to any existing TETS based on E-PA to improve their performance in actual applications. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Modeling treatment of ischemic heart disease with partially observable Markov decision processes.
Hauskrecht, M; Fraser, H
1998-01-01
Diagnosis of a disease and its treatment are not separate, one-shot activities. Instead they are very often dependent and interleaved over time, mostly due to uncertainty about the underlying disease, uncertainty associated with the response of a patient to the treatment and varying cost of different diagnostic (investigative) and treatment procedures. The framework of Partially observable Markov decision processes (POMDPs) developed and used in operations research, control theory and artificial intelligence communities is particularly suitable for modeling such a complex decision process. In the paper, we show how the POMDP framework could be used to model and solve the problem of the management of patients with ischemic heart disease, and point out modeling advantages of the framework over standard decision formalisms.
NASA Technical Reports Server (NTRS)
Vatner, S. F.
1978-01-01
Radiotelemetry was used to measure arterial pressure and mesenteric and renal blood flows from nine unrestrained, conscious baboons during periods of rest, moderate exercise, and extreme excitement. A description of the experiments hardware is presented, including artificial depressants phenylcyclidine hydrochloride, 0.5-1.0 mg/kg, and pentobarbital sodium, 15 mg/kg, and an ultrasonic telemetry flow meter. Results showed rising heart rate and arterial pressure coupled with a reduction of mesenteric and renal flows as the level of exercise was increased. These findings are compared with mesenteric and renal flows somewhat above control level, but relatively stable heart rate and arterial pressure, postprandially. Attention is given to a quantitative analysis of the experimental results.
Simulation of blood flow through an artificial heart
NASA Technical Reports Server (NTRS)
Kiris, Cetin; Chang, I-Dee; Rogers, Stuart E.; Kwak, Dochan
1991-01-01
A numerical simulation of the incompressible viscous flow through a prosthetic tilting disk heart valve is presented in order to demonstrate the current capability to model unsteady flows with moving boundaries. Both steady state and unsteady flow calculations are done by solving the incompressible Navier-Stokes equations in 3-D generalized curvilinear coordinates. In order to handle the moving boundary problems, the chimera grid embedding scheme which decomposes a complex computational domain into several simple subdomains is used. An algebraic turbulence model for internal flows is incorporated to reach the physiological values of Reynolds number. Good agreement is obtained between the numerical results and experimental measurements. It is found that the tilting disk valve causes large regions of separated flow, and regions of high shear.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nose, Y.
Methods were developed for generating an integrated, statistical model of the anatomical structures within the human thorax relevant to radioisotope powered artificial heart implantation. These methods involve measurement and analysis of anatomy in four areas: chest wall, pericardium, vascular connections, and great vessels. A model for the prediction of thorax outline from radiograms was finalized. These models were combined with 100 radiograms to arrive at a size distribution representing the adult male and female populations. (CH)
Long-term in vivo left ventricular assist device study with a titanium centrifugal pump.
Ohtsuka, G; Nakata, K; Yoshikawa, M; Mueller, J; Takano, T; Yamane, S; Gronau, N; Glueck, J; Takami, Y; Sueoka, A; Letsou, G; Schima, H; Schmallegger, H; Wolner, E; Koyanagi, H; Fujisawa, A; Baldwin, J C; Nosé, Y
1998-01-01
A totally implantable centrifugal artificial heart has been developed. The plastic prototype, Gyro PI 601, passed 2 day hemodynamic tests as a functional total artificial heart, 2 week screening tests for antithrombogenicity, and 1 month system feasibility. Based on these results, a metallic prototype, Gyro PI 702, was subjected to in vivo left ventricular assist device (LVAD) studies. The pump system employed the Gyro PI 702, which has the same inner dimensions and the same characteristics as the Gyro PI 601, including an eccentric inlet port, a double pivot bearing system, and a magnet coupling system. The PI 702 is driven with the Vienna DC brushless motor actuator. For the in vivo LVAD study, the pump actuator package was implanted in the preperitoneal space in two calves, from the left ventricular apex to the descending aorta. Case 1 achieved greater than 9 month survival without any complications, at an average flow rate of 6.6 L/min with 10.2 W input power. Case 2 was killed early due to the excessive growth of the calf, which caused functional obstruction of the inlet port. There was no blood clot inside the pump. During these periods, neither case exhibited any physiologic abnormalities. The PI 702 pump gives excellent results as a long-term implantable LVAD.
New concepts and new design of permanent maglev rotary artificial heart blood pumps.
Qian, K X; Zeng, P; Ru, W M; Yuan, H Y
2006-05-01
According to tradition, permanent maglev cannot achieve stable equilibrium. The authors have developed, to the contrary, two stable permanent maglev impeller blood pumps. The first pump is an axially driven uni-ventricular assist pump, in which the rotor with impeller is radially supported by two passive magnetic bearings, but has one point contact with the stator axially at standstill. As the pump raises its rotating speed, the increasing hydrodynamic force of fluid acting on the impeller will make the rotor taking off from contacting point and disaffiliate from the stator. Then the rotor becomes fully suspended. The second pump is a radially driven bi-ventricular assist pump, i.e., an impeller total artificial heart. Its rotor with two impellers on both ends is supported by two passive magnetic bearings, which counteract the attractive force between rotor magnets and stator coil iron core. The rotor is affiliated to the stator radially at standstill and becomes levitated during rotation. Therefore, the rotor keeps concentric with stator during rotation but eccentric at standstill, as is confirmed by rotor position detection with Honeywell sensors. It concludes that the permanent maglev needs action of a non-magnetic force to achieve stability but a rotating magnetic levitator with high speed and large inertia can maintain its stability merely with passive magnetic bearings.
Shiba, Kenji; Nukaya, Masayuki; Tsuji, Toshio; Koshiji, Kohji
2008-01-01
This paper reports on the current density and specific absorption rate (SAR) analysis of biological tissue surrounding an air-core transcutaneous transformer for an artificial heart. The electromagnetic field in the biological tissue is analyzed by the transmission line modeling method, and the current density and SAR as a function of frequency, output voltage, output power, and coil dimension are calculated. The biological tissue of the model has three layers including the skin, fat, and muscle. The results of simulation analysis show SARs to be very small at any given transmission conditions, about 2-14 mW/kg, compared to the basic restrictions of the International Commission on nonionizing radiation protection (ICNIRP; 2 W/kg), while the current density divided by the ICNIRP's basic restrictions gets smaller as the frequency rises and the output voltage falls. It is possible to transfer energy below the ICNIRP's basic restrictions when the frequency is over 250 kHz and the output voltage is under 24 V. Also, the parts of the biological tissue that maximized the current density differ by frequencies; in the low frequency is muscle and in the high frequency is skin. The boundary is in the vicinity of the frequency 600-1000 kHz.
Shiba, Kenji; Nukaya, Masayuki; Tsuji, Toshio; Koshiji, Kohji
2006-01-01
This paper reports on the specific absorption rate (SAR) and the current density analysis of biological tissue surrounding an air-core type of transcutaneous transformer for an artificial heart. The electromagnetic field in the biological tissue surrounding the transformer was analyzed by the transmission-line modeling method, and the SAR and current density as a function of frequency (200k-1 MHz) for a transcutaneous transmission of 20 W were calculated. The model's biological tissue has three layers including the skin, fat and muscle. As a result, the SAR in the vicinity of the transformer is sufficiently small and the normalized SAR value, which is divided by the ICNIRP's basic restriction, is 7 x 10(-3) or less. On the contrary, the current density is slightly in excess of the ICNIRP's basic restrictions as the frequency falls and the output voltage rises. Normalized current density is from 0.2 to 1.2. In addition, the layer in which the current's density is maximized depends on the frequency, the muscle in the low frequency (<700 kHz) and the skin in the high frequency (>700 kHz). The result shows that precision analysis taking into account the biological properties is very important for developing the transcutaneous transformer for TAH.
NASA Astrophysics Data System (ADS)
Bostock, J.; Weller, P.; Cooklin, M.
2010-07-01
Automated diagnostic algorithms are used in implantable cardioverter-defibrillators (ICD's) to detect abnormal heart rhythms. Algorithms misdiagnose and improved specificity is needed to prevent inappropriate therapy. Knowledge engineering (KE) and artificial intelligence (AI) could improve this. A pilot study of KE was performed with artificial neural network (ANN) as AI system. A case note review analysed arrhythmic events stored in patients ICD memory. 13.2% patients received inappropriate therapy. The best ICD algorithm had sensitivity 1.00, specificity 0.69 (p<0.001 different to gold standard). A subset of data was used to train and test an ANN. A feed-forward, back-propagation network with 7 inputs, a 4 node hidden layer and 1 output had sensitivity 1.00, specificity 0.71 (p<0.001). A prospective study was performed using KE to list arrhythmias, factors and indicators for which measurable parameters were evaluated and results reviewed by a domain expert. Waveforms from electrodes in the heart and thoracic bio-impedance; temperature and motion data were collected from 65 patients during cardiac electrophysiological studies. 5 incomplete datasets were due to technical failures. We concluded that KE successfully guided selection of parameters and ANN produced a usable system and that complex data collection carries greater risk of technical failure, leading to data loss.
Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee
In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.
USDA-ARS?s Scientific Manuscript database
This research is the first use of the Box-Jenkins time-series models to describe changes in heart rate (HR) of free-ranging crossbred cows (Bos taurus) receiving both programmed audio cues from directional virtual fencing (DVFTM) devices and non-programmed environmental/physiological cues. The DVFT...
Anguita Sánchez, Manuel; Lambert Rodríguez, José Luis; Bover Freire, Ramón; Comín Colet, Josep; Crespo Leiro, María G; González Vílchez, Francisco; Manito Lorite, Nicolás; Segovia Cubero, Javier; Ruiz Mateas, Francisco; Elola Somoza, Francisco Javier; Íñiguez Romo, Andrés
2016-10-01
The prevalence of heart failure remains high and represents the highest disease burden in Spain. Heart failure units have been developed to systematize the diagnosis, treatment, and clinical follow-up of heart failure patients, provide a structure to coordinate the actions of various entities and personnel involved in patient care, and improve prognosis and quality of life. There is ample evidence on the benefits of heart failure units or programs, which have become widespread in Spain. One of the challenges to the analysis of heart failure units is standardization of their classification, by determining which "programs" can be identified as heart failure "units" and by characterizing their complexity level. The aim of this article was to present the standards developed by the Spanish Society of Cardiology to classify and establish the requirements for heart failure units within the SEC-Excellence project. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
A mock heart engineered with helical aramid fibers for in vitro cardiovascular device testing.
Jansen-Park, So-Hyun; Hsu, Po-Lin; Müller, Indra; Steinseifer, Ulrich; Abel, Dirk; Autschbach, Rüdiger; Rossaint, Rolf; Schmitz-Rode, Thomas
2017-04-01
Mock heart circulation loops (MHCLs) serve as in-vitro platforms to investigate the physiological interaction between circulatory systems and cardiovascular devices. A mock heart (MH) engineered with silicone walls and helical aramid fibers, to mimic the complex contraction of a natural heart, has been developed to advance the MHCL previously developed in our group. A mock aorta with an anatomical shape enables the evaluation of a cannulation method for ventricular assist devices (VADs) and investigation of the usage of clinical measurement systems like pressure-volume catheters. Ventricle and aorta molds were produced based on MRI data and cast with silicone. Aramid fibers were layered in the silicone ventricle to reproduce ventricle torsion. A rotating hollow shaft was connected to the apex enabling the rotation of the MH and the connection of a VAD. Silicone wall thickness, aramid fiber angle and fiber pitch were varied to generate different MH models. All MH models were placed in a tank filled with variable amounts of water and air simulating the compliance. In this work, physiological ventricular torsion angles (15°-26°) and physiological pressure-volume loops were achieved. This MHCL can serve as a comprehensive testing platform for cardiovascular devices, such as artificial heart valves and cannulation of VADs.
Advancements in mechanical circulatory support for patients in acute and chronic heart failure
Csepe, Thomas A.
2017-01-01
Cardiogenic shock (CS) continues to have high mortality and morbidity despite advances in pharmacological, mechanical, and reperfusion approaches to treatment. When CS is refractory to medical therapy, percutaneous mechanical circulatory support (MCS) should be considered. Acute MCS devices, ranging from intra-aortic balloon pumps (IABPs) to percutaneous temporary ventricular assist devices (VAD) to extracorporeal membrane oxygenation (ECMO), can aid, restore, or maintain appropriate tissue perfusion before the development of irreversible end-organ damage. Technology has improved patient survival to recovery from CS, but in patients whom cardiac recovery does not occur, acute MCS can be effectively utilized as a bridge to long-term MCS devices and/or heart transplantation. Heart transplantation has been limited by donor heart availability, leading to a greater role of left ventricular assist device (LVAD) support. In patients with biventricular failure that are ineligible for LVAD implantation, further advancements in the total artificial heart (TAH) may allow for improved survival compared to medical therapy alone. In this review, we discuss the current state of acute and durable MCS, ongoing advances in LVADs and TAH devices, improved methods of durable MCS implantation and patient selection, and future MCS developments in this dynamic field that may allow for optimization of HF treatment. PMID:29268418
Managing health habits for myocardial infarction (MI) patients.
Song, R; Lee, H
2001-08-01
The study examined effects of the heart camp as a motivation enhancement program on cardiac risk reduction and behavioral modification in myocardial infarction (MI) patients. A total of 86 outpatients participated at the first heart camp and 45 returned to the second one in 8 weeks. The first and second heart camps were daylong programs consisted of health assessment, education classes, and Q&A session with interdisciplinary team approach. At the completion of the heart camp, the participants showed significantly lower scores in cardiac risk factors, and significant improvements in motivational variables, especially, perceived benefits and perceived barriers as well as in the performance of diet and exercise behaviors. The study results confirm that it is possible to enhance motivation for chronic patients like MI patients by even short period of comprehensive educational program.
Annotated Bibliography of Publications from the U.S. Navy’s Marine Mammal Program. Revision D.
1998-05-01
Artificial Insemination of Bottlenosed Dolphins. In: The Bottlenosed Dolphin, J. S. Leatherwood and R. R. Reeves (eds.). Academic Press, San Diego, CA...pp. 447-460. 88 The development of semen collection, cryopreservation, and artificial insemination tech- niques for dolphins is reported...R. A. Kastelein (eds.). Plenum Press, New York, pp. 203- 216. Reviews dolphin sonar detection experiments in artificial and natural noise
Natural Object Categorization.
1987-11-01
6-A194 103 NATURAL OBJECT CATEGORIZATION(U) MASSACHUSETTS INST OF 1/3 TECH CAMBRIDGE ARTIFICIAL INTELLIGENCE LAB R F DBICK NOY 87 AI-TR-1091 NBSSI4...ORGANI1ZATION NAME AN40 ACORES$ 10. PROGRAM ELEMENT. PROJECT. TASK Artificial Inteligence Laboratory AREA A WORK UNIT MUMBERS 545 Technology Square Cambridge...describes research done at the Department of Brain and Cognitive Sciences and the Artificial Intelligence Laboratory at the Massachusetts Institute of
Defense Information Systems Program Automated CORDIVEM Design Requirements,
1984-02-28
for the Soviet military organization and equipment. Dr. John Spagnuolo incorporated artificial intelligence techniques in the discussion of functional...4-44 4.1.2.18.2 Artificial Intelligence ...... ........ 4-49 4.1.2.18.3 Types of A.I ................. 4-51 4.1.2.19 General Planning Requirements...described later. Further, some subprocesses may need one of the various techniques associated with the broad field of Artificial Intelligence (A.I.) in
Knowledge-Based Software Development Tools
1993-09-01
GREEN, C., AND WESTFOLD, S. Knowledge-based programming self-applied. In Machine Intelligence 10, J. E. Hayes, D. Mitchie, and Y. Pao, Eds., Wiley...Technical Report KES.U.84.2, Kestrel Institute, April 1984. [181 KORF, R. E. Toward a model of representation changes. Artificial Intelligence 14, 1...Artificial Intelligence 27, 1 (February 1985), 43-96. Replinted in Readings in Artificial Intelligence and Software Engineering, C. Rich •ad R. Waters
ROSIE: A Programming Environment for Expert Systems
1985-10-01
ence on Artificial Inteligence , Tbilisi, USSR, 1975. Fain, J., D. Gorlin, F. Hayes-Roth, S. Rosenschein, H. Sowizral, and D. Waterman, The ROSIE Language...gramming environment for artificial intelligence (AI) applications. It provides particular support for designing expert systems, systems that embody
Watada, Masaya; Saisho, Ryohei; Kim, Yong-Jae; Ohuchi, Katsuhiro; Takatani, Setsuo; Um, Yong-Su
2007-01-01
All implantable devices, such as an artificial heart, an artificial lung, a pacemaker, a defibrillator, need electric power. So the electric power supply through the skin is requested. Then, it is transcutaneous energy transmission system (TETS) that has been studied and used a lot. TETS is the system which performs an electric power supply by non-contact transcutaneously using the electromagnetic induction phenomenon of an external primary side coil and a secondary side coil in human body. In this research, we are developing the core type TETS which applied for the implantable devices. In this paper, corresponding to various conditions, such as a difference in required electric power and transmission distance change, the core type transformer which can hold high transmission efficiency is designed.
Dilles, Ann; Heymans, Valerie; Martin, Sandra; Droogné, Walter; Denhaerynck, Kris; De Geest, Sabina
2011-09-01
Education, coaching and guidance of patients are important components of heart failure management. The aim of this study was to compare a computer assisted learning (CAL) program with standard education (brochures and oral information from nurses) on knowledge and self-care in hospitalized heart failure patients. Satisfaction with the CAL program was also assessed in the intervention group. A quasi-experimental design was used, with a convenience sample of in-hospital heart failure patients. Knowledge and self-care were measured using the Dutch Heart Failure Knowledge Scale and the European Heart Failure Self-care Behaviour Scale at hospital admission, at discharge and after a 3-month follow-up. Satisfaction with the CAL program was assessed at hospital discharge using a satisfaction questionnaire. Within and between groups, changes in knowledge and self-care over time were tested using a mixed regression model. Of 65 heart failure patients screened, 37 were included in the study: 21 in the CAL group and 16 in the usual care group. No significant differences in knowledge (p=0.65) or self-care (p=0.40) could be found between groups. However, both variables improved significantly over time in each study group (p<0.0001). Both educational strategies increased knowledge and improved self-care. The design did not allow isolation of the effects of standard education usual care from CAL. Economic and clinical outcomes of both methods should be evaluated in further research. Copyright © 2010. Published by Elsevier B.V.
Ernstmann, N; Karbach, U
2017-02-01
German and Turkish-speaking patients were recruited for a chronic heart failure management program. So far little is known about the special needs and characteristics of Turkish-speaking patients with chronic heart failure; therefore, the aim of this study was to examine sociodemographic and illness-related differences between German and Turkish-speaking patients with chronic heart failure. German and Turkish-speaking patients suffering from chronic heart failure and insured with the AOK Rheinland/Hamburg or the BARMER GEK health insurance companies and living in Cologne, Germany, were enrolled. Recruitment took place in hospitals, private practices and at information events. Components of the program were coordination of a guideline-oriented medical care, telemonitoring (e.g., blood pressure, electrocardiogram, and weight), a 24-h information hotline, attendance by German and Turkish-speaking nurses and a patient education program. Data were collected by standardized interviews in German or Turkish language. Data were analyzed with descriptive measures and tested for significance differences using Pearson's χ 2 -test and the t‑test. A total of 465 patients (average age 71 years, 55 % male and 33 % Turkish-speaking) were enrolled in the care program during the study period. Significant differences between German and Turkish-speaking patients were found for age, education, employment status, comorbidities, risk perception, knowledge on heart failure and fear of loss of independence. The response rate could be achieved with the help of specific measures for patient enrollment by Turkish-speaking integration nurses. The differences between German and Turkish-speaking patients should in future be taken into account in the care of people with chronic heart failure.
Kutyifa, Valentina; Daubert, James P; Olshansky, Brian; Huang, David T; Zhang, Claire; Ruwald, Anne-Christine H; McNitt, Scott; Zareba, Wojciech; Moss, Arthur J; Schuger, Claudio
2015-09-01
Data on inappropriate implantable cardioverter-defibrillator (ICD) therapy and effects of programming by heart rate are lacking. We aimed to characterize inappropriate ICD therapy and assess the effects of novel programming by heart rate. Incidence and causes of inappropriate therapy by heart rate range (below or above 200 bpm) were assessed. Predictors of inappropriate therapy and effects of programming by heart rate were evaluated with multivariate Cox regression models. Crossovers were excluded. Inappropriate therapy occurred in 9.2% of the total patient population, with 19% of patients randomized to study arm A, 3.6% in arm B, and 4.7% in arm C. Inappropriate therapies <200 bpm were attributable to supraventricular tachycardia (SVT)/sinus tachycardia (78%) or atrial fibrillation/flutter (20%). Inappropriate therapy ≥200 bpm occurred because of SVT (47%), atrial fibrillation/flutter (41%), or electromagnetic interference (13%). Conventional ICD programming was associated with more inappropriate therapy <200 bpm than high-rate or delayed therapy, as were younger age, history of atrial arrhythmia, advanced New York Heart Association functional class, ICD versus cardiac resynchronization therapy with defibrillator, and absence of diabetes. High-rate and long-delay therapy significantly reduced the risk of inappropriate therapy in the <200 bpm range. Long delay was associated with further reduction of fast (≥200 bpm) inappropriate therapy (P = .032) and a reduction in subsequent inappropriate episodes (P = .006). In MADIT-RIT, inappropriate ICD therapy is most frequent at rates below 200 bpm and can be predicted, and effectively prevented, with high-rate cutoff programming. Long-delay therapy effectively reduces fast inappropriate therapy ≥200 bpm and subsequent events. [ http://clinicaltrials.gov/ct2/show/NCT00947310]. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Agboola, Stephen; Jethwani, Kamal; Khateeb, Kholoud; Moore, Stephanie; Kvedar, Joseph
2015-04-22
Given the magnitude of increasing heart failure mortality, multidisciplinary approaches, in the form of disease management programs and other integrative models of care, are recommended to optimize treatment outcomes. Remote monitoring, either as structured telephone support or telemonitoring or a combination of both, is fast becoming an integral part of many disease management programs. However, studies reporting on the evaluation of real-world heart failure remote monitoring programs are scarce. This study aims to evaluate the effect of a heart failure telemonitoring program, Connected Cardiac Care Program (CCCP), on hospitalization and mortality in a retrospective database review of medical records of patients with heart failure receiving care at the Massachusetts General Hospital. Patients enrolled in the CCCP heart failure monitoring program at the Massachusetts General Hospital were matched 1:1 with usual care patients. Control patients received care from similar clinical settings as CCCP patients and were identified from a large clinical data registry. The primary endpoint was all-cause mortality and hospitalizations assessed during the 4-month program duration. Secondary outcomes included hospitalization and mortality rates (obtained by following up on patients over an additional 8 months after program completion for a total duration of 1 year), risk for multiple hospitalizations and length of stay. The Cox proportional hazard model, stratified on the matched pairs, was used to assess primary outcomes. A total of 348 patients were included in the time-to-event analyses. The baseline rates of hospitalizations prior to program enrollment did not differ significantly by group. Compared with controls, hospitalization rates decreased within the first 30 days of program enrollment: hazard ratio (HR)=0.52, 95% CI 0.31-0.86, P=.01). The differential effect on hospitalization rates remained consistent until the end of the 4-month program (HR=0.74, 95% CI 0.54-1.02, P=.06). The program was also associated with lower mortality rates at the end of the 4-month program: relative risk (RR)=0.33, 95% 0.11-0.97, P=.04). Additional 8-months follow-up following program completion did not show residual beneficial effects of the CCCP program on mortality (HR=0.64, 95% 0.34-1.21, P=.17) or hospitalizations (HR=1.12, 95% 0.90-1.41, P=.31). CCCP was associated with significantly lower hospitalization rates up to 90 days and significantly lower mortality rates over 120 days of the program. However, these effects did not persist beyond the 120-day program duration.
Comín-Colet, Josep; Verdú-Rotellar, José María; Vela, Emili; Clèries, Montse; Bustins, Montserrat; Mendoza, Lola; Badosa, Neus; Cladellas, Mercè; Ferré, Sofía; Bruguera, Jordi
2014-04-01
The efficacy of heart failure programs has been demonstrated in clinical trials but their applicability in the real world practice setting is more controversial. This study evaluates the feasibility and efficacy of an integrated hospital-primary care program for the management of patients with heart failure in an integrated health area covering a population of 309,345. For the analysis, we included all patients consecutively admitted with heart failure as the principal diagnosis who had been discharged alive from all of the hospitals in Catalonia, Spain, from 2005 to 2011, the period when the program was implemented, and compared mortality and readmissions among patients exposed to the program with the rates in the patients of all the remaining integrated health areas of the Servei Català de la Salut (Catalan Health Service). We included 56,742 patients in the study. There were 181,204 hospital admissions and 30,712 deaths during the study period. In the adjusted analyses, when compared to the 54,659 patients from the other health areas, the 2083 patients exposed to the program had a lower risk of death (hazard ratio=0.92 [95% confidence interval, 0.86-0.97]; P=.005), a lower risk of clinically-related readmission (hazard ratio=0.71 [95% confidence interval, 0.66-0.76]; P<.001), and a lower risk of readmission for heart failure (hazard ratio=0.86 [95% confidence interval, 0.80-0.94]; P<.001). The positive impact on the morbidity and mortality rates was more marked once the program had become well established. The implementation of multidisciplinary heart failure management programs that integrate the hospital and the community is feasible and is associated with a significant reduction in patient morbidity and mortality. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Future applications of artificial intelligence to Mission Control Centers
NASA Technical Reports Server (NTRS)
Friedland, Peter
1991-01-01
Future applications of artificial intelligence to Mission Control Centers are presented in the form of the viewgraphs. The following subject areas are covered: basic objectives of the NASA-wide AI program; inhouse research program; constraint-based scheduling; learning and performance improvement for scheduling; GEMPLAN multi-agent planner; planning, scheduling, and control; Bayesian learning; efficient learning algorithms; ICARUS (an integrated architecture for learning); design knowledge acquisition and retention; computer-integrated documentation; and some speculation on future applications.
An application of artificial intelligence to the interpretation of mass spectra.
NASA Technical Reports Server (NTRS)
Buchanan, B. G.; Duffield, A. M.; Robertson, A. V.
1971-01-01
Description of the DENDRAL (Dendritic Algorithm) project, the objectives of which were to base the computer program on an alogorithm that generates an exhaustive, nonredundant list of all the structural isomers of a given chemical composition, and to devise a computer program that would perform an organic structure determination, given a molecular formula and a mass spectrum. This program is called 'Heuristic DENDRAL' and it operates by using the known structure/spectrum correlations to constrain the DENDRAL isomer generator to produce a single isomer for that composition. The collaboration of chemists and computer scientists has produced a tool of some practical utility from the chemical viewpoint, and an interesting program from the viewpoint of artificial intelligence.
Marriner, Nick; Morhange, Christophe; Kaniewski, David; Carayon, Nicolas
2014-07-03
Beirut, Sidon and Tyre were major centres of maritime trade from the Bronze Age onwards. This economic prosperity generated increased pressures on the local environment, through urbanization and harbour development. Until now, however, the impact of expanding seaport infrastructure has largely been neglected and there is a paucity of data concerning the environmental stresses caused by these new forms of anthropogenic impacts. Sediment archives from Beirut, Sidon and Tyre are key to understanding human impacts in harbour areas because: (i) they lie at the heart of ancient trade networks; (ii) they encompass the emergence of early maritime infrastructure; and (iii) they enable human alterations of coastal areas to be characterized over long timescales. Here we report multivariate analyses of litho- and biostratigraphic data to probe human stressors in the context of their evolving seaport technologies. The statistical outcomes show a notable break between natural and artificial sedimentation that began during the Iron Age. Three anchorage phases can be distinguished: (i) Bronze Age proto-harbours that correspond to natural anchorages, with minor human impacts; (ii) semi-artificial Iron Age harbours, with stratigraphic evidence for artificial reinforcement of the natural endowments; and (iii) heavy human impacts leading to completely artificial Roman and Byzantine harbours.
Marriner, Nick; Morhange, Christophe; Kaniewski, David; Carayon, Nicolas
2014-01-01
Beirut, Sidon and Tyre were major centres of maritime trade from the Bronze Age onwards. This economic prosperity generated increased pressures on the local environment, through urbanization and harbour development. Until now, however, the impact of expanding seaport infrastructure has largely been neglected and there is a paucity of data concerning the environmental stresses caused by these new forms of anthropogenic impacts. Sediment archives from Beirut, Sidon and Tyre are key to understanding human impacts in harbour areas because: (i) they lie at the heart of ancient trade networks; (ii) they encompass the emergence of early maritime infrastructure; and (iii) they enable human alterations of coastal areas to be characterized over long timescales. Here we report multivariate analyses of litho- and biostratigraphic data to probe human stressors in the context of their evolving seaport technologies. The statistical outcomes show a notable break between natural and artificial sedimentation that began during the Iron Age. Three anchorage phases can be distinguished: (i) Bronze Age proto-harbours that correspond to natural anchorages, with minor human impacts; (ii) semi-artificial Iron Age harbours, with stratigraphic evidence for artificial reinforcement of the natural endowments; and (iii) heavy human impacts leading to completely artificial Roman and Byzantine harbours. PMID:24989979
Iwase, Satoshi
2005-01-01
To test the effectiveness of centrifuge-induced artificial gravity with ergometric exercise, 12 healthy young men (20.7 +/- 1.9 yr) were exposed to simulated microgravity for 14 days of -6 degrees head-down bedrest. Half the subjects were randomly selected and loaded 1.2 G artificial gravity with 60 W (four out of six subjects) or 40 W (two out of six subjects) of ergometric workload on days 1, 2, 3, 5, 7, 9, 11, 12, 13, 14 (CM group). The rest of the subjects served as the control. Anti-G score, defined as the G-load x running time to the endpoint, was significantly elongated by the load of the centrifuge-ergometer. Plasma volume loss was suppressed (-5.0 +/- 2.4 vs. -16.4 +/- 1.9%), and fluid volume shift was prevented by the countermeasure load. Elevated heart rate and muscle sympathetic nerve activity after bedrest were counteracted, and exaggerated response to head-up tilt was also suppressed. Centrifuge-induced artificial gravity with exercise is effective in preventing cardiovascular deconditioning due to microgravity exposure, however, an effective and appropriate regimen (magnitude of G-load and exercise workload) should be determined in future studies. c2005 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Marriner, Nick; Morhange, Christophe; Kaniewski, David; Carayon, Nicolas
2014-07-01
Beirut, Sidon and Tyre were major centres of maritime trade from the Bronze Age onwards. This economic prosperity generated increased pressures on the local environment, through urbanization and harbour development. Until now, however, the impact of expanding seaport infrastructure has largely been neglected and there is a paucity of data concerning the environmental stresses caused by these new forms of anthropogenic impacts. Sediment archives from Beirut, Sidon and Tyre are key to understanding human impacts in harbour areas because: (i) they lie at the heart of ancient trade networks; (ii) they encompass the emergence of early maritime infrastructure; and (iii) they enable human alterations of coastal areas to be characterized over long timescales. Here we report multivariate analyses of litho- and biostratigraphic data to probe human stressors in the context of their evolving seaport technologies. The statistical outcomes show a notable break between natural and artificial sedimentation that began during the Iron Age. Three anchorage phases can be distinguished: (i) Bronze Age proto-harbours that correspond to natural anchorages, with minor human impacts; (ii) semi-artificial Iron Age harbours, with stratigraphic evidence for artificial reinforcement of the natural endowments; and (iii) heavy human impacts leading to completely artificial Roman and Byzantine harbours.
NASA Astrophysics Data System (ADS)
Iwase, Satoshi
2005-07-01
To test the effectiveness of centrifuge-induced artificial gravity with ergometric exercise, 12 healthy young men (20.7±1.9yr) were exposed to simulated microgravity for 14 days of -6∘ head-down bedrest. Half the subjects were randomly selected and loaded 1.2 G artificial gravity with 60 W (four out of six subjects) or 40 W (two out of six subjects) of ergometric workload on days 1,2,3,5,7,9,11,12,13,14 (CM group). The rest of the subjects served as the control. Anti-G score, defined as the G-load×running time to the endpoint, was significantly elongated by the load of the centrifuge-ergometer. Plasma volume loss was suppressed ( -5.0±2.4 vs. -16.4±1.9%), and fluid volume shift was prevented by the countermeasure load. Elevated heart rate and muscle sympathetic nerve activity after bedrest were counteracted, and exaggerated response to head-up tilt was also suppressed. Centrifuge-induced artificial gravity with exercise is effective in preventing cardiovascular deconditioning due to microgravity exposure, however, an effective and appropriate regimen (magnitude of G-load and exercise workload) should be determined in future studies.
Adams, Jenny; Roberts, Joanne; Simms, Kay; Cheng, Dunlei; Hartman, Julie; Bartlett, Charles
2009-03-15
We designed a study to measure the functional capacity requirements of firefighters to aid in the development of an occupation-specific training program in cardiac rehabilitation; 23 healthy male firefighters with no history of heart disease completed a fire and rescue obstacle course that simulated 7 common firefighting tasks. They wore complete personal protective equipment and portable metabolic instruments that included a data collection mask. We monitored each subject's oxygen consumption (VO(2)) and working heart rate, then calculated age-predicted maximum heart rates (220 - age) and training target heart rates (85% of age-predicted maximum heart rate). During performance of the obstacle course, the subjects' mean working heart rates and peak heart rates were higher than the calculated training target heart rates (t(22) = 5.69 [working vs target, p <0.001] and t(22) = 15.14 [peak vs target, p <0.001]). These findings, with mean results for peak VO(2) (3,447 ml/min) and metabolic equivalents (11.9 METs), show that our subjects' functional capacity greatly exceeded that typically attained by patients in traditional cardiac rehabilitation programs (5 to 8 METs). In conclusion, our results indicate the need for intense, occupation-specific cardiac rehabilitation training that will help firefighters safely return to work after a cardiac event.
Care management for low-risk patients with heart failure: a randomized, controlled trial.
DeBusk, Robert Frank; Miller, Nancy Houston; Parker, Kathleen Marie; Bandura, Albert; Kraemer, Helena Chmura; Cher, Daniel Joseph; West, Jeffrey Alan; Fowler, Michael Bruce; Greenwald, George
2004-10-19
Nurse care management programs for patients with chronic illness have been shown to be safe and effective. To determine whether a telephone-mediated nurse care management program for heart failure reduced the rate of rehospitalization for heart failure and for all causes over a 1-year period. Randomized, controlled trial of usual care with nurse management versus usual care alone in patients hospitalized for heart failure from May 1998 through October 2001. 5 northern California hospitals in a large health maintenance organization. Of 2786 patients screened, 462 met clinical criteria for heart failure and were randomly assigned (228 to intervention and 234 to usual care). Nurse care management provided structured telephone surveillance and treatment for heart failure and coordination of patients' care with primary care physicians. Time to first rehospitalization for heart failure or for any cause and time to a combined end point of first rehospitalization, emergency department visit, or death. At 1 year, half of the patients had been rehospitalized at least once and 11% had died. Only one third of rehospitalizations were for heart failure. The rate of first rehospitalization for heart failure was similar in both groups (proportional hazard, 0.85 [95% CI, 0.46 to 1.57]). The rate of all-cause rehospitalization was similar (proportional hazard, 0.98 [CI, 0.76 to 1.27]). The findings of this study, conducted in a single health care system, may not be generalizable to other health care systems. The overall effect of the intervention was minor. Among patients with heart failure at low risk on the basis of sociodemographic and medical attributes, nurse care management did not statistically significantly reduce rehospitalizations for heart failure or for any cause. Such programs may be less effective for patients at low risk than those at high risk.
Counseling, Artificial Intelligence, and Expert Systems.
ERIC Educational Resources Information Center
Illovsky, Michael E.
1994-01-01
Considers the use of artificial intelligence and expert systems in counseling. Limitations are explored; candidates for counseling versus those for expert systems are discussed; programming considerations are reviewed; and techniques for dealing with rational, nonrational, and irrational thoughts and feelings are described. (Contains 46…
Tan, Zhixiang; Zhang, Yi; Zeng, Deping; Wang, Hua
2015-04-01
We proposed a research of a heart sound envelope extraction system in this paper. The system was implemented on LabVIEW based on the Hilbert-Huang transform (HHT). We firstly used the sound card to collect the heart sound, and then implemented the complete system program of signal acquisition, pretreatment and envelope extraction on LabVIEW based on the theory of HHT. Finally, we used a case to prove that the system could collect heart sound, preprocess and extract the envelope easily. The system was better to retain and show the characteristics of heart sound envelope, and its program and methods were important to other researches, such as those on the vibration and voice, etc.
76 FR 19103 - National Heart, Lung, and Blood Institute; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-06
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Heart, Lung, and..., Division of Lung Diseases, National Heart, Lung, and Blood Institute, National Institutes of Health, 6701... Assistance Program Nos. 93.233, National Center for Sleep Disorders Research; 93.837, Heart and [[Page 19104...
78 FR 30319 - National Heart, Lung, and Blood Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-22
...: Heart, Lung, and Blood Initial Review Group; Heart, Lung, and Blood Program Project Review Committee... Blood Institute; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory Committee... clearly unwarranted invasion of personal privacy. Name of Committee: National Heart, Lung, and Blood...
USDA-ARS?s Scientific Manuscript database
A variety of nutrition symbols and rating systems are in use on the front of food packages. They are intended to help consumers make healthier food choices. One system, the American Heart Association Heart (AHA) Heart-Check Program, has evolved over time to incorporate current science-based recommen...
New continuous-flow total artificial heart and vascular permeability.
Feng, Jun; Cohn, William E; Parnis, Steven M; Sodha, Neel R; Clements, Richard T; Sellke, Nicholas; Frazier, O Howard; Sellke, Frank W
2015-12-01
We tested the short-term effects of completely nonpulsatile versus pulsatile circulation after ventricular excision and replacement with total implantable pumps in an animal model on peripheral vascular permeability. Ten calves underwent cardiac replacement with two HeartMate III continuous-flow rotary pumps. In five calves, the pump speed was rapidly modulated to impart a low-frequency pulse pressure in the physiologic range (10-25 mm Hg) at a rate of 40 pulses per minute (PP). The remaining five calves were supported with a pulseless systemic circulation and no modulation of pump speed (NP). Skeletal muscle biopsies were obtained before cardiac replacement (baseline) and on postoperative days (PODs) 1, 7, and 14. Skeletal muscle-tissue water content was measured, and morphologic alterations of skeletal muscle were assessed. VE-cadherin, phospho-VE-cadherin, and CD31 were analyzed by immunohistochemistry. There were no significant changes in tissue water content and skeletal muscle morphology within group or between groups at baseline, PODs 1, 7, and 14, respectively. There were no significant alterations in the expression and/or distribution of VE-cadherin, phospho-VE-cadherin, and CD31 in skeletal muscle vasculature at baseline, PODs 1, 7, and 14 within each group or between the two groups, respectively. Although continuous-flow total artificial heart (CFTAH) with or without a pulse pressure caused slight increase in tissue water content and histologic damage scores at PODs 7 and 14, it failed to reach statistical significance. There was no significant adherens-junction protein degradation and phosphorylation in calf skeletal muscle microvasculature after CFTAH implantation, suggesting that short term of CFTAH with or without pulse pressure did not cause peripheral endothelial injury and did not increase the peripheral microvascular permeability. Copyright © 2015 Elsevier Inc. All rights reserved.
The challenge of home discharge with a total artificial heart: the La Pitie Salpetriere experience.
Demondion, Pierre; Fournel, Ludovic; Niculescu, Michaela; Pavie, Alain; Leprince, Pascal
2013-11-01
The total artificial heart (TAH) helps to counteract the current decrease in heart donors and is likely to bridge patients to transplant under favourable conditions. Today's mobile consoles facilitate home discharge. The aim of this study was to report on the La Pitie Hospital experience with CardioWest TAH recipients, and more particularly, on generally successful outpatient' management. A retrospective analysis was performed on clinical and biological data from patients implanted with a TAH between December 2006 and July 2010 in a single institution. Morbi-mortality during hospital stay, number and causes of rehospitalizations, quality of life during home discharge, bridge to transplant results and survival have all been analysed. Twenty-seven patients were implanted with the CardioWest. Fifteen patients (55.5%) died during support. Prior to home discharge, the most frequent cause of death was multi-organ failure (46.6%). Twelve patients were discharged home from hospital within a median of 88 days [range 35-152, interquartile range 57] postimplantation. Mean rehospitalization rate was 1.2 by patient, on account of device infection (n = 7), technical problems with the console (n = 3) and other causes (n = 4). Between discharge and transplant, patients spent 87% of their support time out of hospital. All patients who returned home with the TAH were subsequently transplanted, and 1 died in post-transplant. Despite the morbidity and mortality occurring during the postimplantation period, home discharge with a TAH is possible. Portables drivers allow for a safe return home. Aside from some remaining weak points such as infectious complications or noise, CardioWest TAH allows for successful rehabilitation of graft candidates, and assures highly satisfactory transplant results.
Okamoto, E; Shimanaka, M; Suzuki, S; Baba, K; Mitamura, Y
1999-01-01
The usefulness of a remote monitoring system that uses a personal handy phone for artificial heart implanted patients was investigated. The type of handy phone used in this study was a personal handy phone system (PHS), which is a system developed in Japan that uses the NTT (Nippon Telephone and Telegraph, Inc.) telephone network service. The PHS has several advantages: high-speed data transmission, low power output, little electromagnetic interference with medical devices, and easy locating of patients. In our system, patients have a mobile computer (Toshiba, Libretto 50, Kawasaki, Japan) for data transmission control between an implanted controller and a host computer (NEC, PC-9821V16) in the hospital. Information on the motor rotational angle (8 bits) and motor current (8 bits) of the implanted motor driven heart is fed into the mobile computer from the implanted controller (Hitachi, H8/532, Yokohama, Japan) according to 32-bit command codes from the host computer. Motor current and motor rotational angle data from inside the body are framed together by a control code (frame number and parity) for data error checking and correcting at the receiving site, and the data are sent through the PHS connection to the mobile computer. The host computer calculates pump outflow and arterial pressure from the motor rotational angle and motor current values and displays the data in real-time waveforms. The results of this study showed that accurate data on motor rotational angle and current could be transmitted from the subjects while they were walking or driving a car to the host computer at a data transmission rate of 9600 bps. This system is useful for remote monitoring of patients with an implanted artificial heart.
Fresiello, Libera; Khir, Ashraf William; Di Molfetta, Arianna; Kozarski, Maciej; Ferrari, Gianfranco
2013-03-01
Despite 50 years of research to assess the intra-aortic balloon pump (IABP) effects on patients' hemodynamics, some issues related to the effects of this therapy are still not fully understood. One of these issues is the effect of IABP, its inflation timing and duration on peripheral circulation autonomic controls. This work provides a systematic analysis of IABP effects on baroreflex using a cardiovascular hybrid model, which consists of computational and hydraulic submodels. The work also included a baroreflex computational model that was connected to a hydraulic model with a 40-cm(3) balloon. The IABP was operated at different inflation trigger timings (-0.14 to 0.31 s) and inflation durations (0.05-0.45 s), with time of the dicrotic notch being taken as t = 0. Baroreflex-dependent parameters-afferent and efferent pathway activity, heart rate, peripheral resistance, and venous tone-were evaluated at each of the inflation trigger times and durations considered. Balloon early inflation (0.09 s before the dicrotic notch) with inflation duration of 0.25 s generated a maximum net increment of afferent pathway activity of 10%, thus leading to a decrement of efferent sympathetic activity by 15.3% compared with baseline values. These times also resulted in a reduction in peripheral resistance and heart rate by 4 and 4.3% compared with baseline value. We conclude that optimum IABP triggering time results in positive effects on peripheral circulation autonomic controls. Conversely, if the balloon is not properly timed, peripheral resistance and heart rate may even increase, which could lead to detrimental outcomes. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Chuvashov, I. N.
2011-07-01
In this paper complex of algorithms and programs for solving inverse problems of artificial earth satellite dynamics is described. Complex has been intended for satellite orbit improvement, calculation of motion model parameters and etc. Programs complex has been worked up for cluster "Skiff Cyberia". Results of numerical experiments obtained by using new complex in common the program "Numerical model of the system artificial satellites motion" is presented in this paper.
An Artificial Particle Precipitation Technique Using HAARP-Generated VLF Waves
2006-11-02
AFRL-VS-HA-TR-2007-1021 An Artificial Particle Precipitation Technique Using HAARP -Generated VLF Waves O o o r- Q M. J. Kosch T. Pedersen J...Artificial Particle Precipitation Technique Using HAARP Generated VLF Waves. 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 62101F...model. The frequency-time modulated VLF wave patterns have been successfully implemented at the HAARP ionospheric modification facility in Alaska
2007-03-01
Intelligence AIS Artificial Immune System ANN Artificial Neural Networks API Application Programming Interface BFS Breadth-First Search BIS Biological...problem domain is too large for only one algorithm’s application . It ranges from network - based sniffer systems, responsible for Enterprise-wide coverage...options to network administrators in choosing detectors to employ in future ID applications . Objectives Our hypothesis validity is based on a set
1989-10-01
Northeast Aritificial Intelligence Consortium (NAIC). i Table of Contents Execu tive Sum m ary...o g~nIl ’vLr COPY o~ T- RADC-TR-89-259, Vol XI (of twelve) N Interim Report SOctober 1989 NORTHEAST ARTIFICIAL INTELLIGENCE CONSORTIUM ANNUAL REPORT...ORGANIZATION 6b. OFFICE SYMBOL 7a. NAME OF MONITORING ORGANIZATION Northeast Artificial (If applicable) Intelligence Consortium (NAIC) . Rome Air Development
Du, Tingsong; Hu, Yang; Ke, Xianting
2015-01-01
An improved quantum artificial fish swarm algorithm (IQAFSA) for solving distributed network programming considering distributed generation is proposed in this work. The IQAFSA based on quantum computing which has exponential acceleration for heuristic algorithm uses quantum bits to code artificial fish and quantum revolving gate, preying behavior, and following behavior and variation of quantum artificial fish to update the artificial fish for searching for optimal value. Then, we apply the proposed new algorithm, the quantum artificial fish swarm algorithm (QAFSA), the basic artificial fish swarm algorithm (BAFSA), and the global edition artificial fish swarm algorithm (GAFSA) to the simulation experiments for some typical test functions, respectively. The simulation results demonstrate that the proposed algorithm can escape from the local extremum effectively and has higher convergence speed and better accuracy. Finally, applying IQAFSA to distributed network problems and the simulation results for 33-bus radial distribution network system show that IQAFSA can get the minimum power loss after comparing with BAFSA, GAFSA, and QAFSA.
Hu, Yang; Ke, Xianting
2015-01-01
An improved quantum artificial fish swarm algorithm (IQAFSA) for solving distributed network programming considering distributed generation is proposed in this work. The IQAFSA based on quantum computing which has exponential acceleration for heuristic algorithm uses quantum bits to code artificial fish and quantum revolving gate, preying behavior, and following behavior and variation of quantum artificial fish to update the artificial fish for searching for optimal value. Then, we apply the proposed new algorithm, the quantum artificial fish swarm algorithm (QAFSA), the basic artificial fish swarm algorithm (BAFSA), and the global edition artificial fish swarm algorithm (GAFSA) to the simulation experiments for some typical test functions, respectively. The simulation results demonstrate that the proposed algorithm can escape from the local extremum effectively and has higher convergence speed and better accuracy. Finally, applying IQAFSA to distributed network problems and the simulation results for 33-bus radial distribution network system show that IQAFSA can get the minimum power loss after comparing with BAFSA, GAFSA, and QAFSA. PMID:26447713
CTCF counter-regulates cardiomyocyte development and maturation programs in the embryonic heart.
Gomez-Velazquez, Melisa; Badia-Careaga, Claudio; Lechuga-Vieco, Ana Victoria; Nieto-Arellano, Rocio; Tena, Juan J; Rollan, Isabel; Alvarez, Alba; Torroja, Carlos; Caceres, Eva F; Roy, Anna R; Galjart, Niels; Delgado-Olguin, Paul; Sanchez-Cabo, Fatima; Enriquez, Jose Antonio; Gomez-Skarmeta, Jose Luis; Manzanares, Miguel
2017-08-01
Cardiac progenitors are specified early in development and progressively differentiate and mature into fully functional cardiomyocytes. This process is controlled by an extensively studied transcriptional program. However, the regulatory events coordinating the progression of such program from development to maturation are largely unknown. Here, we show that the genome organizer CTCF is essential for cardiogenesis and that it mediates genomic interactions to coordinate cardiomyocyte differentiation and maturation in the developing heart. Inactivation of Ctcf in cardiac progenitor cells and their derivatives in vivo during development caused severe cardiac defects and death at embryonic day 12.5. Genome wide expression analysis in Ctcf mutant hearts revealed that genes controlling mitochondrial function and protein production, required for cardiomyocyte maturation, were upregulated. However, mitochondria from mutant cardiomyocytes do not mature properly. In contrast, multiple development regulatory genes near predicted heart enhancers, including genes in the IrxA cluster, were downregulated in Ctcf mutants, suggesting that CTCF promotes cardiomyocyte differentiation by facilitating enhancer-promoter interactions. Accordingly, loss of CTCF disrupts gene expression and chromatin interactions as shown by chromatin conformation capture followed by deep sequencing. Furthermore, CRISPR-mediated deletion of an intergenic CTCF site within the IrxA cluster alters gene expression in the developing heart. Thus, CTCF mediates local regulatory interactions to coordinate transcriptional programs controlling transitions in morphology and function during heart development.
CTCF counter-regulates cardiomyocyte development and maturation programs in the embryonic heart
Gomez-Velazquez, Melisa; Badia-Careaga, Claudio; Lechuga-Vieco, Ana Victoria; Nieto-Arellano, Rocio; Rollan, Isabel; Alvarez, Alba; Torroja, Carlos; Caceres, Eva F.; Roy, Anna R.; Galjart, Niels; Sanchez-Cabo, Fatima; Enriquez, Jose Antonio; Gomez-Skarmeta, Jose Luis
2017-01-01
Cardiac progenitors are specified early in development and progressively differentiate and mature into fully functional cardiomyocytes. This process is controlled by an extensively studied transcriptional program. However, the regulatory events coordinating the progression of such program from development to maturation are largely unknown. Here, we show that the genome organizer CTCF is essential for cardiogenesis and that it mediates genomic interactions to coordinate cardiomyocyte differentiation and maturation in the developing heart. Inactivation of Ctcf in cardiac progenitor cells and their derivatives in vivo during development caused severe cardiac defects and death at embryonic day 12.5. Genome wide expression analysis in Ctcf mutant hearts revealed that genes controlling mitochondrial function and protein production, required for cardiomyocyte maturation, were upregulated. However, mitochondria from mutant cardiomyocytes do not mature properly. In contrast, multiple development regulatory genes near predicted heart enhancers, including genes in the IrxA cluster, were downregulated in Ctcf mutants, suggesting that CTCF promotes cardiomyocyte differentiation by facilitating enhancer-promoter interactions. Accordingly, loss of CTCF disrupts gene expression and chromatin interactions as shown by chromatin conformation capture followed by deep sequencing. Furthermore, CRISPR-mediated deletion of an intergenic CTCF site within the IrxA cluster alters gene expression in the developing heart. Thus, CTCF mediates local regulatory interactions to coordinate transcriptional programs controlling transitions in morphology and function during heart development. PMID:28846746
Pulsatility flow around a single cylinder - an experimental model of flow inside an artificial lung
NASA Astrophysics Data System (ADS)
Lin, Yu-Chun; Bull, Joseph L.
2004-11-01
Pulsatile flow past a single cylinder is experimentally investigated using particle image velocimetry. This study aims to elucidate the effects of pulstility on the velocity field, which influences the convection-dominated transport within the fluid. The artificial lung device can be connected in parallel or series with the native lungs and may potentially be used as a bridge to transplant or for pulmonary replacement. The artificial lung consists of hollow microfibers through which gas flows and blood flows around. Blood flow through the device is pulsatile because it is driven entirely by the right heart. Steady flow over bluff bodies has been investigated in many contexts, such as heat exchangers. However, few studies have been investigated the effect of pulsatility. The effects of frequency, amplitude of pulsatility, and average flow rate on the formation of vortices after a cylinder are examined. Vortices near the cylinder are found to develop at lower Reynolds number in pulsatile flow than in steady flow. This work is supported by NIH grant R01 HL69420-01.
Computational Hemodynamics Involving Artificial Devices
NASA Technical Reports Server (NTRS)
Kwak, Dochan; Kiris, Cetin; Feiereisen, William (Technical Monitor)
2001-01-01
This paper reports the progress being made towards developing complete blood flow simulation capability in human, especially, in the presence of artificial devices such as valves and ventricular assist devices. Devices modeling poses unique challenges different from computing the blood flow in natural hearts and arteries. There are many elements needed such as flow solvers, geometry modeling including flexible walls, moving boundary procedures and physiological characterization of blood. As a first step, computational technology developed for aerospace applications was extended in the recent past to the analysis and development of mechanical devices. The blood flow in these devices is practically incompressible and Newtonian, and thus various incompressible Navier-Stokes solution procedures can be selected depending on the choice of formulations, variables and numerical schemes. Two primitive variable formulations used are discussed as well as the overset grid approach to handle complex moving geometry. This procedure has been applied to several artificial devices. Among these, recent progress made in developing DeBakey axial flow blood pump will be presented from computational point of view. Computational and clinical issues will be discussed in detail as well as additional work needed.
A thin film nitinol heart valve.
Stepan, Lenka L; Levi, Daniel S; Carman, Gregory P
2005-11-01
In order to create a less thrombogenic heart valve with improved longevity, a prosthetic heart valve was developed using thin film nitinol (NiTi). A "butterfly" valve was constructed using a single, elliptical piece of thin film NiTi and a scaffold made from Teflon tubing and NiTi wire. Flow tests and pressure readings across the valve were performed in vitro in a pulsatile flow loop. Bio-corrosion experiments were conducted on untreated and passivated thin film nitinol. To determine the material's in vivo biocompatibility, thin film nitinol was implanted in pigs using stents covered with thin film NiTi. Flow rates and pressure tracings across the valve were comparable to those through a commercially available 19 mm Perimount Edwards tissue valve. No signs of corrosion were present on thin film nitinol samples after immersion in Hank's solution for one month. Finally, organ and tissue samples explanted from four pigs at 2, 3, 4, and 6 weeks after thin film NiTi implantation appeared without disease, and the thin film nitinol itself was without thrombus formation. Although long term testing is still necessary, thin film NiTi may be very well suited for use in artificial heart valves.
Hybrid Applications Of Artificial Intelligence
NASA Technical Reports Server (NTRS)
Borchardt, Gary C.
1988-01-01
STAR, Simple Tool for Automated Reasoning, is interactive, interpreted programming language for development and operation of artificial-intelligence application systems. Couples symbolic processing with compiled-language functions and data structures. Written in C language and currently available in UNIX version (NPO-16832), and VMS version (NPO-16965).
A Starter's Guide to Artificial Intelligence.
ERIC Educational Resources Information Center
McConnell, Barry A.; McConnell, Nancy J.
1988-01-01
Discussion of the history and development of artificial intelligence (AI) highlights a bibliography of introductory books on various aspects of AI, including AI programing; problem solving; automated reasoning; game playing; natural language; expert systems; machine learning; robotics and vision; critics of AI; and representative software. (LRW)
Artificial consciousness and the consciousness-attention dissociation.
Haladjian, Harry Haroutioun; Montemayor, Carlos
2016-10-01
Artificial Intelligence is at a turning point, with a substantial increase in projects aiming to implement sophisticated forms of human intelligence in machines. This research attempts to model specific forms of intelligence through brute-force search heuristics and also reproduce features of human perception and cognition, including emotions. Such goals have implications for artificial consciousness, with some arguing that it will be achievable once we overcome short-term engineering challenges. We believe, however, that phenomenal consciousness cannot be implemented in machines. This becomes clear when considering emotions and examining the dissociation between consciousness and attention in humans. While we may be able to program ethical behavior based on rules and machine learning, we will never be able to reproduce emotions or empathy by programming such control systems-these will be merely simulations. Arguments in favor of this claim include considerations about evolution, the neuropsychological aspects of emotions, and the dissociation between attention and consciousness found in humans. Ultimately, we are far from achieving artificial consciousness. Copyright © 2016 Elsevier Inc. All rights reserved.
Teachers and artificial intelligence. The Logo connection.
Merbler, J B
1990-12-01
This article describes a three-phase program for training special education teachers to teach Logo and artificial intelligence. Logo is derived from the LISP computer language and is relatively simple to learn and use, and it is argued that these factors make it an ideal tool for classroom experimentation in basic artificial intelligence concepts. The program trains teachers to develop simple demonstrations of artificial intelligence using Logo. The material that the teachers learn to teach is suitable as an advanced level topic for intermediate- through secondary-level students enrolled in computer competency or similar courses. The material emphasizes problem-solving and thinking skills using a nonverbal expressive medium (Logo), thus it is deemed especially appropriate for hearing-impaired children. It is also sufficiently challenging for academically talented children, whether hearing or deaf. Although the notion of teachers as programmers is controversial, Logo is relatively easy to learn, has direct implications for education, and has been found to be an excellent tool for empowerment-for both teachers and children.
Olypher, Andrey; Cymbalyuk, Gennady; Calabrese, Ronald L
2006-12-01
The leech heartbeat CPG is paced by the alternating bursting of pairs of mutually inhibitory heart interneurons that form elemental half-center oscillators. We explore the control of burst duration in heart interneurons using a hybrid system, where a living, pharmacologically isolated, heart interneuron is connected with artificial synapses to a model heart interneuron running in real-time, by focusing on a low-voltage-activated (LVA) calcium current I(CaS). The transition from silence to bursting in this half-center oscillator occurs when the spike frequency of the bursting interneuron declines to a critical level, f(Final), at which the inhibited interneuron escapes owing to a build-up of the hyperpolarization-activated cation current, I(h). We varied I(CaS) inactivation time constant either in the living heart interneuron or in the model heart interneuron. In both cases, varying I(CaS) inactivation time constant did not affect f(Final) of either interneuron, but in the varied interneuron, the time constant of decline of spike frequency during bursts to f(Final) and thus the burst duration varied directly and nearly linearly with I(CaS) inactivation time constant. Bursts of the opposite, nonvaried interneuron did not change. We show also that control of burst duration by I(CaS) inactivation does not require synaptic interaction by reconstituting autonomous bursting in synaptically isolated living interneurons with injected I(CaS). Therefore inactivation of LVA calcium current is critically important for setting burst duration and thus period in a heart interneuron half-center oscillator and is potentially a general intrinsic mechanism for regulating burst duration in neurons.
Bäcker, Henrik; Polgár, Livia; Soós, Pal; Lajkó, Eszter; Láng, Orsolya; Merkely, Bela; Szabó, Gabor; Dohmen, Pascal M.; Weymann, Alexander; Kőhidai, Laszlo
2017-01-01
Background Experiments on porcine heart scaffold represent significant assays in development of immunoneutral materials for cardiac surgery. Characterization of cell-cell and cell-scaffold interactions is essential to understand the homing process of cardiac cells into the scaffolds. Material/Methods In the present study, the highly sensitive and real-time impedimetric technique of xCELLigence SP was used to monitor cell adhesion, which is the key process of recellularization in heart scaffolds. Our objectives were: (i) to characterize the effect of decellularized porcine heart scaffold on cell adhesion of human cardiovascular cells potentially used in the recellularization process; and (ii) to investigate cell-extracellular matrix element interactions for building artificial multi-layer systems, applied as cellular models of recellularization experiments. Human fibrosarcoma, endothelial, and cardiomyocyte cells were investigated and the effect of decellularized porcine heart scaffold (HS) and fibronectin on cell adhesion was examined. Adhesion was quantified as slope of curves. Results Heart scaffold had neutral effect on cardiomyocytes as well as on endothelial cells. Adhesion of cardiomyocytes was increased by fibronectin (1.480±0.021) compared to control (0.745±0.029). The combination of fibronectin and HS induced stronger adhesion of cardiomyocytes (2.407±0.634) than fibronectin alone. Endothelial and fibrosarcoma cells showed similarly strong adhesion profiles with marked enhancer effect by fibronectin. Conclusions Decellularized porcine HS does not inhibit adhesion of human cardiovascular cells at the cell biological level, while fibronectin has strong cell adhesion-inducer effect, as well as an enhancer effect on activity of HS. Consequently, decellularized porcine hearts could be used as scaffolds for recellularization with cardiomyocytes and endothelial cells with fibronectin acting as a regulator, leading to construction of working bioartificial hearts. PMID:28493851
Naveed, Muhammad; Han, Lei; Khan, Ghulam Jilany; Yasmeen, Sufia; Mikrani, Reyaj; Abbas, Muhammad; Cunyu, Li; Xiaohui, Zhou
2018-06-01
Congestive heart failure (CHF) is a complicated pathophysiological syndrome, leading cause of hospitalization as well as mortalities in developed countries wherein an irregular function of the heart leads to the insufficient blood supply to the body organs. It is an accumulative slackening of various complications including myocardial infarction (MI), coronary heart disease (CAD), hypertension, valvular heart disease (VHD) and cardiomyopathy; its hallmarks include hypertrophy, increased interstitial fibrosis and loss of myocytes. The etiology of CHF is very complex and despite the rapid advancement in pharmacological and device-based interventional therapies still, a single therapy may not be sufficient to meet the demand for coping with the diseases. Total artificial hearts (TAH) and ventricular assist devices (VADs) have been widely used clinically to assist patients with severe HF. Unfortunately, direct contact between the patient's blood and device leads to thromboembolic events, and then coagulatory factors, as well as, infection contribute significantly to complicate the situation. There is no effective treatment of HF except cardiac transplantation, however, genetic variations, tissue mismatch; differences in certain immune response and socioeconomic crisis are an important concern with cardiac transplantation suggesting an alternate bridge to transplant (BTT) or destination therapies (DT). For these reasons, researchers have turned to mechanically driven compression devices, ventricular restraint devices (VRD) and heart patches. The ASD is a combination of all operational patches and cardiac support devices (CSD) by delivering biological agents and can restrain or compress the heart. Present study summarizes the accessible peer-reviewed literature focusing on the mechanism of Direct Cardiac Compression (DCC) devices, VRD and patches and their acquaintance to optimize the therapeutic efficacy in a synergistic way. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Myocardial NF-κB activation is essential for zebrafish heart regeneration
Karra, Ravi; Knecht, Anne K.; Kikuchi, Kazu; Poss, Kenneth D.
2015-01-01
Heart regeneration offers a novel therapeutic strategy for heart failure. Unlike mammals, lower vertebrates such as zebrafish mount a strong regenerative response following cardiac injury. Heart regeneration in zebrafish occurs by cardiomyocyte proliferation and reactivation of a cardiac developmental program, as evidenced by induction of gata4 regulatory sequences in regenerating cardiomyocytes. Although many of the cellular determinants of heart regeneration have been elucidated, how injury triggers a regenerative program through dedifferentiation and epicardial activation is a critical outstanding question. Here, we show that NF-κB signaling is induced in cardiomyocytes following injury. Myocardial inhibition of NF-κB activity blocks heart regeneration with pleiotropic effects, decreasing both cardiomyocyte proliferation and epicardial responses. Activation of gata4 regulatory sequences is also prevented by NF-κB signaling antagonism, suggesting an underlying defect in cardiomyocyte dedifferentiation. Our results implicate NF-κB signaling as a key node between cardiac injury and tissue regeneration. PMID:26472034
Myocardial NF-κB activation is essential for zebrafish heart regeneration.
Karra, Ravi; Knecht, Anne K; Kikuchi, Kazu; Poss, Kenneth D
2015-10-27
Heart regeneration offers a novel therapeutic strategy for heart failure. Unlike mammals, lower vertebrates such as zebrafish mount a strong regenerative response following cardiac injury. Heart regeneration in zebrafish occurs by cardiomyocyte proliferation and reactivation of a cardiac developmental program, as evidenced by induction of gata4 regulatory sequences in regenerating cardiomyocytes. Although many of the cellular determinants of heart regeneration have been elucidated, how injury triggers a regenerative program through dedifferentiation and epicardial activation is a critical outstanding question. Here, we show that NF-κB signaling is induced in cardiomyocytes following injury. Myocardial inhibition of NF-κB activity blocks heart regeneration with pleiotropic effects, decreasing both cardiomyocyte proliferation and epicardial responses. Activation of gata4 regulatory sequences is also prevented by NF-κB signaling antagonism, suggesting an underlying defect in cardiomyocyte dedifferentiation. Our results implicate NF-κB signaling as a key node between cardiac injury and tissue regeneration.
Waagstein, Finn; Rutherford, John D
2017-09-05
Finn Waagstein was born in Copenhagen in 1938. He graduated from Aarhus University Medical School in 1964. He received his cardiology training in the Sahlgrenska University Hospital at the University of Gothenburg, Sweden. He was appointed Associate Professor in 1980, and he assisted in establishing and directing the first Swedish heart transplant program. From 1990 he directed the heart failure and cardiomyopathy research programs. He is currently Professor of Cardiology and senior physician at Wallenberg Laboratory. In 2002, he was awarded the King Faisal International Prize for Medicine. © 2017 American Heart Association, Inc.
Jaarsma, T; Halfens, R; Senten, M; Abu Saad, H H; Dracup, K
1998-01-01
Recovery from heart failure and coping with the effects of this serious condition has a major impact on the self-care demand of patients with heart failure. To prevent potential self-care deficits, education and support are important issues in nursing care. The purpose of this article is to describe the development of a supportive-educative program that is designed to enhance self-care abilities of patients with heart failure. To structure nursing care for these patients and their families in a consistent systematized way, Orem's general theory of nursing is used as a frame of reference.
Zhu, Li-Xia; Ho, Shuk-Ching; Wong, Thomas K S
2013-11-01
Regular exercise has been shown to be beneficial to patients with heart disease. Previous studies have indicated that health education can effectively increase participants' physical activity. However, no systematic review was conducted to evaluate the effectiveness of health education programs on changing exercise behavior among patients with heart disease. The aim of this study was to examine the effectiveness of health education programs on exercise behavior among heart disease patients. Potential studies were retrieved in the Cochrane Central Register of Controlled Trials, MEDLINE, CINAHL, EMbase, PsycINFO, the British Nursing Index and Archive, Science Direct, and ERIC via EBSCOhost. Meta-analysis was done using the random-effect model. Thirty-seven studies were identified. Only 12 studies delivered health education based on various theories/models. Twenty-eight studies were included in the meta-analyses. The results showed that health education had significantly positive effects on exercise adherence (risk ratio = 1.35 to 1.48), exercise duration (SMD = 0.25 to 0.69), exercise frequency (MD = 0.54 to 1.46 session/week), and exercise level (SMD = 0.25), while no significant effects were found on exercise energy expenditure and cognitive exercise behavior. Health education has overall positive effects on changing exercise behavior among heart disease patients. Few theoretical underpinning studies were conducted for changing exercise behavior among heart disease patients. The findings suggest that health education improves exercise behavior for heart disease patients. Health professionals should reinforce health education programs for them. © 2013 Chinese Cochrane Center, West China Hospital of Sichuan University and Wiley Publishing Asia Pty Ltd.
[Psychophysiological studies in the pre-school children].
Ullner, R; von Braun, G S; Ziegelmayer, G
1976-10-14
The behavior of 24 children, aged 3-6 years, was recorded on video-tape. Simultaneously the ECG was recorded telemetrically. These observations were made during two pre-school educational programs lasting 90 minutes each: "Didactic games" and "Elementary music and movement program". For each child a scale was developed to show the correlation of mean heart-rate and well defined motor-activity. It was evident that the mean heart-rate was higher during the music program than during the didactic program, corresponding to the higher motor-activity. But it was found that in the didactic program the variation of the heart-rate within short intervals was higher due to the more frequent occurrence of respiratory arrhythmias. It was also seen that during the music program the children showed no signs of exertion as they did towards the end of the didactic program. Respiratory arrhythmias were not seen in children who according to the Schellong-test were classified as stable in their cardiovascular system. The arrhythmias occurred mainly when the children showed signs of fatigue.
ERIC Educational Resources Information Center
Meng, Karin; Seekatz, Bettina; Haug, Günter; Mosler, Gabriele; Schwaab, Bernhard; Worringen, Ulrike; Faller, Hermann
2014-01-01
Patient education is an essential part of the treatment of coronary heart disease in cardiac rehabilitation. In Germany, no standardized and evaluated patient education programs for coronary heart disease have been available so far. In this article, we report the evaluation of a patient-oriented program. A multicenter quasi-experimental,…
Gender differences in blood pressure regulation following artificial gravity exposure
NASA Astrophysics Data System (ADS)
Evans, Joyce; Goswami, Nandu; Kostas, Vladimir; Zhang, Qingguang; Ferguson, Connor; Moore, Fritz; Stenger, Michael, , Dr; Serrador, Jorge; W, Siqi
Introduction. Before countermeasures to space flight cardiovascular deconditioning are established, gender differences in cardiovascular responses to orthostatic stress, in general, and to orthostatic stress following exposure to artificial gravity (AG), in particular, need to be determined. Our recent determination that a short exposure to AG improved the orthostatic tolerance limit (OTL) of cardiovascularly deconditioned subjects drives the current effort to determine mechanisms of that improvement in men and in women. Methods. We determined the OTL of 9 men and 8 women following a 90 min exposure to AG compared to that following 90 min of head down bed rest (HDBR). On both days (21 days apart), subjects were made hypovolemic (low salt diet plus 20 mg intravenous furosemide) and orthostatic tolerance was determined from a combination of head up tilt and increasing lower body negative pressure until presyncope. Mean values and correlations with OTL were determined for heart rate, blood pressure, stroke volume, cardiac output, total peripheral resistance (Finometer), middle cerebral artery flow velocity (DWL), partial pressure of carbon dioxide (Novametrics) and body segmental impedance (UFI THRIM) at supine baseline, during orthostatic stress to presyncope and at supine recovery. Results. Orthostatic tolerance of these hypovolemic subjects was significantly greater following AG than following HDBR. Exposure to AG increased cardiac output in both men and women and increased stroke volume in women. In addition, AG decreased systolic blood pressure in men, but not women, and increased cerebral flow in women, but not men. In both men and women, AG exposure decreased peripheral resistance and decreased cerebrovascular resistance in women. Men’s heart rate rose more at the end of OTL on their AG, compared to their HDBR, day but women’s fell. Presyncopal stroke volume reached the same level on each day of study for both men and women. Conclusions. In the present study, men and women demonstrated significantly different strategies for regulating blood pressure and cerebral flow both at rest and during orthostatic stress on the day in which they had undergone exposure to AG. Since, in both men and women, a single, acute bout of AG exposure improved orthostatic tolerance, the feasibility of short exposures to AG during longer spaceflights or prior to entry into a gravitational (Earth or Mars) environment, should be explored. Given the known beneficial effects of AG on other organ systems, the present study indicates that the positive effect of artificial gravity on cardiac output make AG a likely candidate for sustaining cardiovascular conditioning upon return to gravity. Supported by KY NASA EPSCoR Grant #NNX07AT58A, KY State Matching Grants, NASA JSC Human Research Program and NASA Ames Research Center.
Lifestyle modification with diet and exercise in obese patients with heart failure - A pilot study
USDA-ARS?s Scientific Manuscript database
There is a paucity of data regarding intentional weight loss in obese heart failure patients. This study sought to ascertain the safety and effectiveness of a lifestyle modification program in patients with systolic heart failure and metabolic syndrome. Patients (n=20) with systolic heart failure (e...
77 FR 30541 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Heart, Lung, and... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group; Heart, Lung, and Blood Program Project Review Committee. Date: June 15, 2012. Time: 8 a.m. to 5 p.m...
76 FR 10912 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-28
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Heart, Lung, and... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group, Heart, Lung, and Blood Program Project Review Committee. Date: March 18, 2011. Time: 8 a.m. to 5 p.m...
77 FR 12599 - National Heart, Lung, and Blood Institute; Notice of Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Heart, Lung, and... unwarranted invasion of personal privacy. Name of Committee: Heart, Lung, and Blood Initial Review Group, Heart, Lung, and Blood Program Project Review Committee. Date: March 23, 2012. Time: 8 a.m. to 2 p.m...
Berg, Gregory D; Wadhwa, Sandeep; Johnson, Alan E
2004-10-01
To investigate the utilization and financial outcomes of a telephonic nursing disease-management program for elderly patients with heart failure. A 1-year concurrent matched-cohort study employing propensity score matching. Medicare+Choice recipients residing in Ohio, Kentucky, and Indiana. A total of 533 program participants aged 65 and older matched to nonparticipants. Disease-management heart failure program employing a structured, evidence-based, telephonic nursing intervention designed to provide patient education, counseling, and monitoring services. Medical service utilization, including hospitalizations, emergency department visits, medical doctor visits, skilled nursing facility (SNF) days, selected clinical indicators, and financial effect. The intervention group had considerably and significantly lower rates of acute service utilization than the control group, including 23% fewer hospitalizations, 26% fewer inpatient bed days, 22% fewer emergency department visits, 44% fewer heart failure hospitalizations, 70% fewer 30-day readmissions, and 45% fewer SNF bed days. Claims costs were 1,792 dollars per person lower in the intervention group than in the control group (inclusive of intervention costs), and the return on investment was calculated to be 2.31. The study demonstrates that a commercially delivered heart failure disease-management program significantly reduced hospitalizations, emergency department visits, and SNF days. The intervention group had 17% lower costs than the control group; when intervention costs were included, the intervention group had 10% lower costs.
Protect your heart: a culture-specific multimedia cardiovascular health education program.
Shah, Amy; Clayman, Marla L; Glass, Sara; Kandula, Namratha R
2015-04-01
South Asians, the second fastest growing racial/ethnic minority in the United States, have high rates of coronary heart disease. Few coronary heart disease prevention efforts target this population. The authors developed and tested a culture-specific, multimedia coronary heart disease prevention education program in English and Hindi for South Asians. Participants were recruited from community organizations in Chicago, Illinois, between June and October of 2011. Bilingual interviewers used questionnaires to assess participants' knowledge and perceptions before and after the patient education program. The change from pretest score to posttest score was calculated using a paired t test. Linear regression was used to determine the association between posttest scores and education and language. Participants' (N = 112) average age was 41 years, 67% had more than a high school education, and 50% spoke Hindi. Participants' mean pretest score was 15 (SD = 4). After the patient education program, posttest scores increased significantly among all participants (posttest score = 24, SD = 4), including those with limited English proficiency. Lower education was associated with a lower posttest score (β = -2.2, 95% CI [-0.68, -3.83]) in adjusted regression. A culture-specific, multimedia patient education program significantly improved knowledge and perceptions about coronary heart disease prevention among South Asian immigrants. Culturally salient multimedia education may be an effective and engaging way to deliver health information to diverse patient populations.
Telerehabilitation for patients with heart failure.
Tousignant, Michel; Mampuya, Warner Mbuila
2015-02-01
Heart failure is a chronic and progressive condition that is associated with high morbidity and mortality rates. Even though cardiac rehabilitation (CR) has been shown to be beneficial to heart failure patients, only a very small proportion of them will actually be referred and eventually participate. The low participation rate is due in part to accessibility and travel difficulties. Telerehabilitation is a new approach in the rehabilitation field that allows patients to receive a complete rehabilitation program at home in a safe manner and under adequate supervision. We believe that by increasing accessibility to CR, telerehabilitation programs will significantly improve heart failure patients' functional capacity and quality of life. However, it is crucial to provide policy makers with evidence-based data on cardiac telerehabilitation if we want to see its successful implementation in heart failure patients.
Artificial Intelligence Applications to Videodisc Technology
Vries, John K.; Banks, Gordon; McLinden, Sean; Moossy, John; Brown, Melanie
1985-01-01
Much of medical information is visual in nature. Since it is not easy to describe pictorial information in linguistic terms, it has been difficult to store and retrieve this type of information. Coupling videodisc technology with artificial intelligence programming techniques may provide a means for solving this problem.
2014-05-27
closely coupled, could lead to new materials for artificial photosynthesis and organic electronics. The views, opinions and/or findings contained in...new materials for artificial photosynthesis and organic electronics. (a) Papers published in peer-reviewed journals (N/A for none) Enter List of
Computer Intelligence: Unlimited and Untapped.
ERIC Educational Resources Information Center
Staples, Betsy
1983-01-01
Herbert Simon (Nobel prize-winning economist/professor) expresses his views on human and artificial intelligence, problem solving, inventing concepts, and the future. Includes comments on expert systems, state of the art in artificial intelligence, robotics, and "Bacon," a computer program that finds scientific laws hidden in raw data.…
Artificial Intelligence: The Expert Way.
ERIC Educational Resources Information Center
Bitter, Gary G.
1989-01-01
Discussion of artificial intelligence (AI) and expert systems focuses on their use in education. Characteristics of good expert systems are explained; computer software programs that contain applications of AI are described, highlighting one used to help educators identify learning-disabled students; and the future of AI is discussed. (LRW)
ERIC Educational Resources Information Center
Fox, Edward A.
1987-01-01
Discusses the CODER system, which was developed to investigate the application of artificial intelligence methods to increase the effectiveness of information retrieval systems, particularly those involving heterogeneous documents. Highlights include the use of PROLOG programing, blackboard-based designs, knowledge engineering, lexicological…
AM: An Artificial Intelligence Approach to Discovery in Mathematics as Heuristic Search
1976-07-01
Artificial Intelligence Approach to Discovery in Mathematics as Heuristic Search by Douglas B. Len-t APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED (A...570 AM: An Artificial Intelligence Approach to Discovery in Mathematics as Heuristic Search by Douglas B. Lenat ABSTRACT A program, called "AM", is...While AM’s " approach " to empirical research may be used in other scientific domains, the main limitation (reliance on hindsight) will probably recur
1988-06-01
Continue on reverse if necessary and identify by block number) FIELD GROUP SUB-GROUP Computer Assisted Instruction; Artificial Intelligence 194...while he/she tries to perform given tasks. Means-ends analysis, a classic technique for solving search problems in Artificial Intelligence, has been...he/she tries to perform given tasks. Means-ends analysis, a classic technique for solving search problems in Artificial Intelligence, has been used
Planning treatment of ischemic heart disease with partially observable Markov decision processes.
Hauskrecht, M; Fraser, H
2000-03-01
Diagnosis of a disease and its treatment are not separate, one-shot activities. Instead, they are very often dependent and interleaved over time. This is mostly due to uncertainty about the underlying disease, uncertainty associated with the response of a patient to the treatment and varying cost of different diagnostic (investigative) and treatment procedures. The framework of partially observable Markov decision processes (POMDPs) developed and used in the operations research, control theory and artificial intelligence communities is particularly suitable for modeling such a complex decision process. In this paper, we show how the POMDP framework can be used to model and solve the problem of the management of patients with ischemic heart disease (IHD), and demonstrate the modeling advantages of the framework over standard decision formalisms.
Collado-Mesa, Fernando; Alvarez, Edilberto; Arheart, Kris
2018-02-21
Advances in artificial intelligence applied to diagnostic radiology are predicted to have a major impact on this medical specialty. With the goal of establishing a baseline upon which to build educational activities on this topic, a survey was conducted among trainees and attending radiologists at a single residency program. An anonymous questionnaire was distributed. Comparisons of categorical data between groups (trainees and attending radiologists) were made using Pearson χ 2 analysis or an exact analysis when required. Comparisons were made using the Wilcoxon rank sum test when the data were not normally distributed. An α level of 0.05 was used. The overall response rate was 66% (69 of 104). Thirty-six percent of participants (n = 25) reported not having read a scientific medical article on the topic of artificial intelligence during the past 12 months. Twenty-nine percent of respondents (n = 12) reported using artificial intelligence tools during their daily work. Trainees were more likely to express doubts on whether they would have pursued diagnostic radiology as a career had they known of the potential impact artificial intelligence is predicted to have on the specialty (P = .0254) and were also more likely to plan to learn about the topic (P = .0401). Radiologists lack exposure to current scientific medical articles on artificial intelligence. Trainees are concerned by the implications artificial intelligence may have on their jobs and desire to learn about the topic. There is a need to develop educational resources to help radiologists assume an active role in guiding and facilitating the development and implementation of artificial intelligence tools in diagnostic radiology. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.