Sample records for artificial joint replacements

  1. Artificial atlanto-odontoid joint replacement through a transoral approach.

    PubMed

    Lu, Bin; He, Xi Jing; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong

    2009-01-01

    Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1-C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P B 0.021) and NZ (P B 0.002) and a significantly increased stiffness (P \\ 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P C 0.719), NZ (P C 0.580), and stiffness (P C 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities.

  2. Artificial atlanto-odontoid joint replacement through a transoral approach

    PubMed Central

    Lu, Bin; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong

    2008-01-01

    Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1–C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P ≤ 0.021) and NZ (P ≤ 0.002) and a significantly increased stiffness (P < 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P ≥ 0.719), NZ (P ≥ 0.580), and stiffness (P ≥ 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities. PMID:19043745

  3. Etidronate

    MedlinePlus

    ... the skeleton) in people who have had total hip replacement surgery (surgery to replace the hip joint with an artificial joint) or in people ... 8 ounces [180 to 240 mL]) of plain water while you are sitting or standing. Sit or ...

  4. Numerical simulation of artificial hip joint motion based on human age factor

    NASA Astrophysics Data System (ADS)

    Ramdhani, Safarudin; Saputra, Eko; Jamari, J.

    2018-05-01

    Artificial hip joint is a prosthesis (synthetic body part) which usually consists of two or more components. Replacement of the hip joint due to the occurrence of arthritis, ordinarily patients aged or older. Numerical simulation models are used to observe the range of motion in the artificial hip joint, the range of motion of joints used as the basis of human age. Finite- element analysis (FEA) is used to calculate stress von mises in motion and observes a probability of prosthetic impingement. FEA uses a three-dimensional nonlinear model and considers the position variation of acetabular liner cups. The result of numerical simulation shows that FEA method can be used to analyze the performance calculation of the artificial hip joint at this time more accurate than conventional method.

  5. Surface Modifications for Improved Wear Performance in Artificial Joints: A Review

    NASA Astrophysics Data System (ADS)

    Sullivan, Stacey J. L.; Topoleski, L. D. Timmie

    2015-11-01

    Artificial joint replacement is one of the most successful treatments for arthritis. Excellent wear and corrosion resistance, together with high strength and fracture toughness, are fundamental requirements for implant materials. Wear and/or corrosion of the materials used in artificial joints may lead to implant failure. Therefore, hard and wear-resistant materials, like cobalt-chromium-molybdenum and ceramic, are currently used as bearing surfaces. However, even using such hard materials, wear and/or corrosion related failure of artificial joints remains a central concern. One primary goal in orthopedic biomaterials research is to create more wear-resistant surfaces. Different technologies have been used to create new surfaces, or to modify existing surfaces, to prevent wear. It is the intent of this overview first to provide a summary of materials currently used as bearing surfaces in artificial joints, their functions, and their contributions to device longevity. Then, we will discuss advancements in modifying those bearing surfaces to produce more wear-resistant artificial joints.

  6. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus.

    PubMed

    Jin, Z M; Dowson, D; Fisher, J

    1997-01-01

    Lubrication mechanisms and contact mechanics have been analysed for total hip joint replacements made from hard bearing surfaces such as metal-on-metal and ceramic-on-ceramic. A similar analysis for ultra-high molecular weight polyethylene (UHMWPE) against a hard bearing surface has also been carried out and used as a reference. The most important factor influencing the predicted lubrication film thickness has been found to be the radial clearance between the ball and the socket. Full fluid film lubrication may be achieved in these hard/hard bearings provided that the surface finish of the bearing surface and the radial clearance are chosen correctly and maintained. Furthermore, there is a close relation between the predicted contact half width and the predicted lubrication film thickness. Therefore, it is important to analyse the contact mechanics in artificial hip joint replacements. Practical considerations of manufacturing these bearing surfaces have also been discussed.

  7. Three-dimensional human femoral strain analysis using ESPI

    NASA Astrophysics Data System (ADS)

    Tyrer, J. R.; Heras-Palou, C.; Slater, T.

    With age, disease or injury the joints in the human body can wear out or bones may even fail catastrophically. In many cases it is possible to replace joints and bones with artificial components (prostheses). However, prosthetic joints can have a very limited life (often less than 10 years) and require replacement or 'revision'. In order to optimise prosthetic life, it is necessary to improve the design of components and implantation techniques, which is clearly also beneficial to both patients and hospitals.

  8. Recent advances and future directions in the management of knee osteoarthritis: Can biological joint reconstruction replace joint arthroplasty and when?

    PubMed Central

    Paschos, Nikolaos K

    2015-01-01

    In this article, a concise description of the recent advances in the field of osteoarthritis management is presented. The main focus is to highlight the most promising techniques that emerge in both biological joint replacement and artificial joint arthroplasty. A critical view of high quality evidence regarding outcome and safety profile of these techniques is presented. The potential role of kinematically aligned total knee replacement, navigation, and robotic-assisted surgery is outlined. A critical description of both primary and stem cell-based therapies, the cell homing theory, the use of biologic factors and recent advancements in tissue engineering and regenerative medicine is provided. Based on the current evidence, some thoughts on a realistic approach towards answering these questions are attempted. PMID:26495242

  9. Alloplastic total temporomandibular joint replacements: do they perform like natural joints? Prospective cohort study with a historical control.

    PubMed

    Wojczyńska, A; Leiggener, C S; Bredell, M; Ettlin, D A; Erni, S; Gallo, L M; Colombo, V

    2016-10-01

    The aim of this study was to qualitatively and quantitatively describe the biomechanics of existing total alloplastic reconstructions of temporomandibular joints (TMJ). Fifteen patients with unilateral or bilateral TMJ total joint replacements and 15 healthy controls were evaluated via dynamic stereometry technology. This non-invasive method combines three-dimensional imaging of the subject's anatomy with jaw tracking. It provides an insight into the patient's jaw joint movements in real time and provides a quantitative evaluation. The patients were also evaluated clinically for jaw opening, protrusive and laterotrusive movements, pain, interference with eating, and satisfaction with the joint replacements. The qualitative assessment revealed that condyles of bilateral total joint replacements displayed similar basic motion patterns to those of unilateral prostheses. Quantitatively, mandibular movements of artificial joints during opening, protrusion, and laterotrusion were all significantly shorter than those of controls. A significantly restricted mandibular range of motion in replaced joints was also observed clinically. Fifty-three percent of patients suffered from chronic pain at rest and 67% reported reduced chewing function. Nonetheless, patients declared a high level of satisfaction with the replacement. This study shows that in order to gain a comprehensive understanding of complex therapeutic measures, a multidisciplinary approach is needed. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Aircraft to Medicine

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This video discusses how the technology of computer modeling can improve the design and durability of artificial joints for human joint replacement surgery. Also, ultrasound, originally used to detect structural flaws in aircraft, can also be used to quickly assess the severity of a burn patient's injuries, thus aiding the healing process.

  11. Selection of contact bearing couple materials for hip prosthesis using finite element analysis under static conditions

    NASA Astrophysics Data System (ADS)

    Arirajan, K. A.; Chockalingam, K.; Vignesh, C.

    2018-04-01

    Implants are the artificial parts to replace the missing bones or joints in human anatomy to give mechanical support. Hip joint replacement is an important issue in orthopaedic surgery. The main concern limiting the long-run success of the total hip replacement is the limited service life. Hip replacement technique is widely used in replacing the femur head and acetabular cup by materials that are highly biocompatible. The success of the artificial hip replacement depends upon proper material selection, structure, and shape of the hip prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. It is a critical task for selecting the best material pair in the hip prosthesis design. This work develops the finite element analysis of an artificial hip implant to study highest von Mises stress, contact pressure and elastic strain occurs for the dissimilar material combination. The different bearing couple considered for the analysis are Metal on Metal, Metal on Plastic, Metal on Ceramic, Ceramic on Plastic, Ceramic on Ceramic combinations. The analysis is carried out at different static positions of a human (i.e) standing, sitting. The results reveals that the combination with metal in contact with plastic (i.e) Titanium femoral head paired with Ultra High Molecular Weight Poly Ethylene acetabular cup reduces maximum von Mises stress and also it gives lowest contact pressure than other combination of bearing couples.

  12. Ulf Fernström (1915-1985) and his Contributions to the Development of Artificial Disc Replacements.

    PubMed

    Fisahn, Christian; Burgess, Brittni; Iwanaga, Joe; Chapman, Jens R; Oskouian, Rod J; Tubbs, R Shane

    2017-02-01

    Artificial disc replacements, which serve the function of separating vertebrae to allow for proper spinal alignment, can help treat debilitating low back pain in patients who have failed other conservative methods of treatment. A Swedish surgeon, Ulf Fernström, was the pioneer of artificial disc replacement, and his contribution in the form of Fernström balls dramatically altered spinal surgery and technique by showing the proper technique and implant that should be used for areas requiring motion in many planes. Ulf Fernström created his artificial disc inspired by the movement of the hip and knee joints. His implants attempted to restore disc spacing and articulation in patients who had failed conservative measures of treatment. Fernström balls were the first implants of their kind and represent the first attempt at artificial disc replacement. However, many surgeons and researchers questioned Fernström balls, claiming that their lack of elastic properties could damage patients. Of the wide range of implants on the market for the intervertebral disc space, all designs and applications of products stem from the initial discovery made by Fernström, thus making him a pioneer in disc replacement. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Construction of Finite Element Model for an Artificial Atlanto-Odontoid Joint Replacement and Analysis of Its Biomechanical Properties.

    PubMed

    Hu, Yong; Dong, Wei-Xin; Hann, Shannon; Yuan, Zhen-Shan; Sun, Xiao-Yang; Xie, Hui; Zhang, Meichao

    To investigate the stress distribution on artificial atlantoaxial-odontoid joint (AAOJ) components during flexion, extension, lateral bending and rotation of AAOJ model constructed with the finite element (FE) method. Human cadaver specimens of normal AAOJ were CT scanned with 1 mm -thickness and transferred into Mimics software to reconstruct the three-dimensional models of AAOJ. These data were imported into Freeform software to place a AAOJ into a atlantoaxial model. With Ansys software, a geometric model of AAOJ was built. Perpendicular downward pressure of 40 N was applied to simulate gravity of a skull, then 1.53 N• m torque was exerted separately to simulate the range of motion of the model. An FE model of atlantoaxial joint after AAOJ replacement was constructed with a total of 103 053 units and 26 324 nodes. In flexion, extension, right lateral bending and right rotation, the AAOJ displacement was 1.109 mm, 3.31 mm, 0.528 mm, and 9.678 mm, respectively, and the range of motion was 1.6°, 5.1°, 4.6° and 22°. During all ROM, stress distribution of atlas-axis changed after AAOJ replacement indicating that AAOJ can offload stress. The stress distribution in the AAOJ can be successfully analyzed with the FE method.

  14. Measurements of hip-bone distortions caused by the stress of inserted prosthesis by means of the speckle photography method

    NASA Astrophysics Data System (ADS)

    Gajda, Jerzy K.; Niesterowicz, Andrzej; Mazurkiewicz, Henryk

    1995-03-01

    A high number of osseous diseases, particularly of the backbone and hip-joint regions, result in a need for their overall treatment and prevention. Two basic treatment methods are used: physical exercises at an early stage of the illness, and surgical treatment in an advanced stage. Recently, in operational treatment of coxarthrosis the elements of the joint (acetabulum and capitellum) were replaced by their artificial counterparts, despite some drawbacks and unknowns related to this kind of treatment. In order to check the effectiveness of this treatment and to eliminate its drawbacks we have tested the joint by means of speckle photography method. The objective of this paper is an attempt to evaluate stress and displacement distributions in a system consisting of artificial acetabulum and capitellum and a natural bone in order to determine an optimum fitting of artificial acetabulum and capitellum and a natural bone in order to determine an optimum fitting of artificial elements that guarantees uniform distribution of stresses corresponding to anatomical and physiological parameters of the hip-joint. Speckle photographs have been analyzed point by point with the help of the algorithm for striped images processing.

  15. Evaluation of Rock Joint Coefficients

    NASA Astrophysics Data System (ADS)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    A computer method for evaluation of rock joint coefficients is described and several applications are presented. The method is based on two absolute numerical indicators that are formed by means of the Fourier replicas of rock joint profiles. The first indicator quantifies the vertical depth of profiles and the second indicator classifies wavy character of profiles. The absolute indicators have replaced the formerly used relative indicators that showed some artificial behavior in some cases. This contribution is focused on practical computations testing the functionality of the newly introduced indicators.

  16. Surface characteristics of bioactive Ti fabricated by chemical treatment for cartilaginous-integration.

    PubMed

    Miyajima, Hiroyuki; Ozer, Fusun; Imazato, Satoshi; Mante, Francis K

    2017-09-01

    Artificial hip joints are generally expected to fail due to wear after approximately 15years and then have to be replaced by revision surgery. If articular cartilage can be integrated onto the articular surfaces of artificial joints in the same way as osseo-integration of titanium dental implants, the wear of joint implants may be reduced or prevented. However, very few studies have focused on the relationship between Ti surface and cartilage. To explore the possibility of cartilaginous-integration, we fabricated chemically treated Ti surfaces with H 2 O 2 /HCl, collagen type II and SBF, respectively. Then, we evaluated surface characteristics of the prepared Ti samples and assessed the cartilage formation by culturing chondrocytes on the Ti samples. When oxidized Ti was immersed in SBF for 7days, apatite was formed on the Ti surface. The surface characteristics of Ti indicated that the wettability was increased by all chemical treatments compared to untreated Ti, and that H 2 O 2 /HCl treated surface had significantly higher roughness compared to the other three groups. Chondrocytes produced significantly more cartilage matrix on all chemically treated Ti surfaces compared to untreated Ti. Thus, to realize cartilaginous-integration and to prevent wear of the implants in joints, application of bioactive Ti formed by chemical treatment would be a promising and effective strategy to improve durability of joint replacement. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Normalization of load and clearance effects in ball-in-socket-like replacements.

    PubMed

    Ciavarella, M; Strozzi, A; Baldini, A; Giacopini, M

    2007-08-01

    A normalizing loading parameter useful in summarising the mechanical response of plane pin-in-plate-like contacts is extended to axisymmetric ball-in-socket-like contacts. An example addressing a compliant layered artificial hip joint is presented, and the usefulness of the normalizing loading parameter is evidenced.

  18. HiL simulation in biomechanics: a new approach for testing total joint replacements.

    PubMed

    Herrmann, Sven; Kaehler, Michael; Souffrant, Robert; Rachholz, Roman; Zierath, János; Kluess, Daniel; Mittelmeier, Wolfram; Woernle, Christoph; Bader, Rainer

    2012-02-01

    Instability of artificial joints is still one of the most prevalent reasons for revision surgery caused by various influencing factors. In order to investigate instability mechanisms such as dislocation under reproducible, physiologically realistic boundary conditions, a novel test approach is introduced by means of a hardware-in-the-loop (HiL) simulation involving a highly flexible mechatronic test system. In this work, the underlying concept and implementation of all required units is presented enabling comparable investigations of different total hip and knee replacements, respectively. The HiL joint simulator consists of two units: a physical setup composed of a six-axes industrial robot and a numerical multibody model running in real-time. Within the multibody model, the anatomical environment of the considered joint is represented such that the soft tissue response is accounted for during an instability event. Hence, the robot loads and moves the real implant components according to the information provided by the multibody model while transferring back the position and resisting moment recorded. Functionality of the simulator is proved by testing the underlying control principles, and verified by reproducing the dislocation process of a standard total hip replacement. HiL simulations provide a new biomechanical testing tool for analyzing different joint replacement systems with respect to their instability behavior under realistic movements and physiological load conditions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Corrosion behaviour and mechanical properties of functionally gradient materials developed for possible hard-tissue applications.

    PubMed

    Becker, B S; Bolton, J D

    1997-12-01

    Artificial hip joints have an average lifetime of 10 years due to aseptic loosening of the femoral stem attributed to polymeric wear debris; however, there is a steadily increasing demand from younger osteoarthritis patients aged between 15 and 40 year for a longer lasting joint of 25 years or more. Compliant layers incorporated into the acetabular cup generate elastohydrodynamic lubrication conditions between the bearing surfaces, reduce joint friction coefficients and wear debris production and could increase the average life of total hip replacements, and other human load-bearing joint replacements, i.e. total knee replacements. Poor adhesion between a fully dense substrate and the compliant layer has so far prevented any further exploitation. This work investigated the possibility of producing porous metallic, functionally gradient type acetabular cups using powder metallurgy techniques - where a porous surface was supported by a denser core - into which the compliant layers could be incorporated. The corrosion behaviour and mechanical properties of three biomedically approved alloys containing two levels of total porosity (>30% and <10%) were established, resulting in Ti-6Al-4V being identified as the most promising biocompatible functionally graded material, not only for this application but for other hard-tissue implants.

  20. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    PubMed

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

    PubMed

    Reinders, Jörn; Sonntag, Robert; Kretzer, Jan Philippe

    2014-11-01

    Polyethylene wear (PE) is known to be a limiting factor in total joint replacements. However, a standardized wear test (e.g. ISO standard) can only replicate the complex in vivo loading condition in a simplified form. In this study, two different parameters were analyzed: (a) Bovine serum, as a substitute for synovial fluid, is typically replaced every 500,000 cycles. However, a continuous regeneration takes place in vivo. How does serum-replacement interval affect the wear rate of total knee replacements? (b) Patients with an artificial joint show reduced gait frequencies compared to standardized testing. What is the influence of a reduced frequency? Three knee wear tests were run: (a) reference test (ISO), (b) testing with a shortened lubricant replacement interval, (c) testing with reduced frequency. The wear behavior was determined based on gravimetric measurements and wear particle analysis. The results showed that the reduced test frequency only had a small effect on wear behavior. Testing with 1 Hz frequency is therefore a valid method for wear testing. However, testing with a shortened replacement interval nearly doubled the wear rate. Wear particle analysis revealed only small differences in wear particle size between the different tests. Wear particles were not linearly released within one replacement interval. The ISO standard should be revised to address the marked effects of lubricant replacement interval on wear rate.

  2. The influence of resting periods on friction in the artificial hip.

    PubMed

    Nassutt, Roman; Wimmer, Markus A; Schneider, Erich; Morlock, Michael M

    2003-02-01

    Insufficient tribologic performance of total joint components is a major cause of prostheses failure. Wear has been studied intensively using testing machines that apply continuous motions. Human locomotion, however, is not well represented by continuous motions alone. Singular events and resting periods are a substantial part of daily activities. Resting does influence adhesion in the artificial joint with possible effects on friction, wear, and loosening. The current study evaluated the effects of resting on the frictional properties of hip prosthesis components. The activity measurements of 32 patients with artificial hip replacements were analyzed for resting durations of the hip. A pin-on-ball screening device was used to determine friction after characteristic resting periods and during continuous oscillating motion. All common articulation pairings were investigated. Prolonged and frequent resting periods of the hip were found for the patients. Initial friction increased with increasing resting duration for all tested materials (between 41% and 191%). The metal-on-metal articulations showed the highest friction level (0.098 for sliding) and the highest increase (191%) in friction with resting duration (0.285 after resting periods of 60 seconds). A high static frictional moment after resting periods might present a risk for aseptic implant loosening. Therefore, large head diameters of metal-on-metal joints should be used with caution, especially when additional unfavorable risk factors such as obesity, weak bone-implant interface, or high activity level are present.

  3. Development of a Wearable Assist Robot for Walk Rehabilitation After Knee Arthroplasty Surgery

    NASA Astrophysics Data System (ADS)

    Terada, H.; Zhu, Y.; Horiguchi, K.; Nakamura, M.; Takahashi, R.

    In Japan, it is popular that the disease knee joints will be replaced to artificial joints by surgery. And we have to assist so many patients for walk rehabilitation. So, the wearable assist robot has been developed. This robot includes the knee motion assist mechanism and the hip joint support mechanism. Especially, the knee motion assist mechanism consists of a non-circular gear and grooved cams. This mechanism rotates and slides simultaneously, which has two degree-of-freedom. Also, the hip joint support mechanism consists of a hip brace and a ball-joint. This mechanism can avoid motion constraints which are the internal or external rotation and the adduction or abduction. Then, the control algorithm, which considers an assisting timing for the walk rehabilitation, has been proposed. A sensing system of a walk state for this control system uses a heel contacts sensor and knee and hip joint rotation angle sensors. Also, the prototype robot has been tested. And it is confirmed that the assisting system is useful.

  4. Inspection of defects of composite materials in inner cylindrical surfaces using endoscopic shearography

    NASA Astrophysics Data System (ADS)

    Macedo, Fabiano Jorge; Benedet, Mauro Eduardo; Fantin, Analucia Vieira; Willemann, Daniel Pedro; da Silva, Fábio Aparecido Alves; Albertazzi, Armando

    2018-05-01

    This work presents the development of a special shearography system with radial sensitivity and explores its applicability for detecting adhesion flaws on internal surfaces of flanged joints of composite material pipes. The inspection is performed from the inner surface of the tube where the flange is adhered. The system uses two conical mirrors to achieve radial sensitivity. A primary 45° conical mirror is responsible for promoting the inspection of the internal tubular surface on its 360° A special Michelson interferometer is formed replacing one of the plane mirrors by a conical mirror. The image reflected by this conical mirror is shifted away from the image center in a radial way and a radial shear is produced on the images. The concept was developed and a prototype built and tested. First, two tubular steel specimens internally coated with composite material and having known artificial defects were analyzed to test the ability of the system to detect the flaws. After the principle validation, two flanged joints were then analyzed: (a) a reference one, without any artificial defects and (b) a test one with known artificial defects, simulating adhesion failures with different dimensions and locations. In all cases, thermal loading was applied through a hot air blower on the outer surface of the joint. The system presented very good results on all inspected specimens, being able to detect adhesion flaws present in the flanged joints. The experimental results obtained in this work are promising and open a new front for inspections of inner surfaces of pipes with shearography.

  5. The Influence Of Component Alignment On The Life Of Total Knee Prostheses

    NASA Astrophysics Data System (ADS)

    Bugariu, Delia; Bereteu, Liviu

    2012-12-01

    An arthritic knee affects the patient's life by causing pain and limiting movement. If the cartilage and the bone surfaces are severely affected, the natural joint is replaced with an artificial joint. The procedure is called total knee arthroplasty (TKA). Lately, the numbers of implanted total knee prostheses grow steadily. An important factor in TKA is the perfect alignment of the total knee prosthesis (TKP) components. Component misalignment can lead to the prosthesis loss by producing wear particles. The paper proposes a study on mechanical behaviors of a TKP based on numerical analysis, using ANSYS software. The numerical analysis is based on both the normal and the changed angle of the components alignment.

  6. No evidence for the use of DIR, D–D fusions, chromosome 15 open reading frames or VHreplacement in the peripheral repertoire was found on application of an improved algorithm, JointML, to 6329 human immunoglobulin H rearrangements

    PubMed Central

    Ohm-Laursen, Line; Nielsen, Morten; Larsen, Stine R; Barington, Torben

    2006-01-01

    Antibody diversity is created by imprecise joining of the variability (V), diversity (D) and joining (J) gene segments of the heavy and light chain loci. Analysis of rearrangements is complicated by somatic hypermutations and uncertainty concerning the sources of gene segments and the precise way in which they recombine. It has been suggested that D genes with irregular recombination signal sequences (DIR) and chromosome 15 open reading frames (OR15) can replace conventional D genes, that two D genes or inverted D genes may be used and that the repertoire can be further diversified by heavy chain V gene (VH) replacement. Safe conclusions require large, well-defined sequence samples and algorithms minimizing stochastic assignment of segments. Two computer programs were developed for analysis of heavy chain joints. JointHMM is a profile hidden Markow model, while JointML is a maximum-likelihood-based method taking the lengths of the joint and the mutational status of the VH gene into account. The programs were applied to a set of 6329 clonally unrelated rearrangements. A conventional D gene was found in 80% of unmutated sequences and 64% of mutated sequences, while D-gene assignment was kept below 5% in artificial (randomly permutated) rearrangements. No evidence for the use of DIR, OR15, multiple D genes or VH replacements was found, while inverted D genes were used in less than 1‰ of the sequences. JointML was shown to have a higher predictive performance for D-gene assignment in mutated and unmutated sequences than four other publicly available programs. An online version 1·0 of JointML is available at http://www.cbs.dtu.dk/services/VDJsolver. PMID:17005006

  7. [The development of research in tribology of artificial joints].

    PubMed

    Dai, Zhendong; Gong, Juanqing

    2006-06-01

    Aseptic loosening of the prosthesis is a major form for the failure of artificial joints, which results in the conglomeration of wear particles at the bone-implant interface. This paper briefly reviews the recent development of tribology of artificial joints preserving good lubrication, enhancing the wear resistance of materials for the joints, reducing the generation of sensitive-size particles and depressing the debris-tissue reactions. Suggestion for improvement in the design of artificial joints is presented.

  8. The fundamentals of biotribology and its application to spine arthroplasty

    PubMed Central

    Harper, Megan L.; Dooris, Andrew; Paré, Philippe E.

    2009-01-01

    The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results. PMID:25802638

  9. Hereditary hemochromatosis as a risk factor for joint replacement surgery.

    PubMed

    Sahinbegovic, Enijad; Dallos, Tomás; Aigner, Elmar; Axmann, Roland; Engelbrecht, Matthias; Schöniger-Hekele, Maximilian; Karonitsch, Thomas; Farkas, Martin; Karger, Thomas; Willeit, Johann; Stölzel, Ulrich; Keysser, Gernot; Datz, Christian; Kiechl, Stefan; Schett, Georg; Zwerina, Jochen

    2010-07-01

    Hemochromatosis is an inherited disease with iron overload and joint involvement resembling osteoarthritis. To determine the rate of joint replacement surgery in patients with hemochromatosis, we performed a cross-sectional cohort study. A total of 199 individuals with hereditary hemochromatosis were included. The prevalence of joint replacement surgery in hip, knee, and ankle joints because of secondary osteoarthritis was assessed. Data were compared with 917 healthy subjects from the population-based Bruneck study. A total of 32 of 199 individuals with hemochromatosis received joint replacement surgery with a total number of 52 joints replaced. Compared with expected rates in healthy individuals, patients with hemochromatosis had a significantly higher risk for joint replacement surgery (odds ratio 9.0; confidence interval, 4.6-17.4). Joint replacement occurred significantly earlier in life in patients with hemochromatosis; 21.9% of the patients with hemochromatosis and 1.7% of healthy individuals required joint replacement before the age of 50 years (P=.0027). Moreover, patients with hemochromatosis were more likely to require multiple joint replacements (8.5%) than the control group (expected rate 0.3%; P=.0001). Hemochromatosis is a risk factor for joint replacement surgery because of severe secondary osteoarthritis. Copyright 2010 Elsevier Inc. All rights reserved.

  10. [Partial replacement of the knee joint with patient-specific instruments and implants (ConforMIS iUni, iDuo)].

    PubMed

    Beckmann, J; Steinert, A; Zilkens, C; Zeh, A; Schnurr, C; Schmitt-Sody, M; Gebauer, M

    2016-04-01

    Knee arthroplasty is a successful standard procedure in orthopedic surgery; however, approximately 20 % of patients are dissatisfied with the clinical results as they suffer pain and can no longer achieve the presurgery level of activity. According to the literature the reasons are inexact fitting of the prosthesis or too few anatomically formed implants resulting in less physiological kinematics of the knee joint. Reducing the number of dissatisfied patients and the corresponding number of revisions is an important goal considering the increasing need for artificial joints. In this context, patient-specific knee implants are an obvious alternative to conventional implants. For the first time implants are now matched to the individual bone and not vice versa to achieve the best possible individual situation and geometry and more structures (e.g. ligaments and bone) are preserved or only those structures are replaced which were actually destroyed by arthrosis. According to the authors view, this represents an optimal and pioneering addition to conventional implants. Patient-specific implants and the instruments needed for correct alignment and fitting can be manufactured by virtual 3D reconstruction and 3D printing based on computed tomography (CT) scans. The portfolio covers medial as well as lateral unicondylar implants, medial as well as lateral bicompartmental implants (femorotibial and patellofemoral compartments) and cruciate ligament-preserving as well as cruciate ligament-substituting total knee replacements; however, it must be explicitly emphasized that the literature is sparse and no long-term data are available.

  11. Prerequisites for Deriving Formal Specifications from Natural Language Requirements.

    DTIC Science & Technology

    1983-04-01

    International Joint Conference on Artificial Intell1ence, American Association for Artificial Intelligence, Mento Park, CA, 1981, 385-387. Mann, William C...Centering". Proceedings of the Seventh International Joint Conference on Artificial Intelligence, American Association for Artificial Intelligence, Mento

  12. Crack Damage Parameters and Dilatancy of Artificially Jointed Granite Samples Under Triaxial Compression

    NASA Astrophysics Data System (ADS)

    Walton, G.; Alejano, L. R.; Arzua, J.; Markley, T.

    2018-06-01

    A database of post-peak triaxial test results was created for artificially jointed planes introduced in cylindrical compression samples of a Blanco Mera granite. Aside from examining the artificial jointing effect on major rock and rock mass parameters such as stiffness, peak strength and residual strength, other strength parameters related to brittle cracking and post-yield dilatancy were analyzed. Crack initiation and crack damage values for both the intact and artificially jointed samples were determined, and these damage envelopes were found to be notably impacted by the presence of jointing. The data suggest that with increased density of jointing, the samples transition from a combined matrix damage and joint slip yielding mechanism to yield dominated by joint slip. Additionally, post-yield dilation data were analyzed in the context of a mobilized dilation angle model, and the peak dilation angle was found to decrease significantly when there were joints in the samples. These dilatancy results are consistent with hypotheses in the literature on rock mass dilatancy.

  13. Arthroscopic procedures and therapeutic results of anatomical reconstruction of the coracoclavicular ligaments for acromioclavicular Joint dislocation.

    PubMed

    Takase, K; Yamamoto, K

    2016-09-01

    Surgical treatment is recommended for type 5 acromioclavicular joint dislocation on Rockwood's classification. We believe that anatomic repair of the coracoclavicular ligaments best restores the function of the acromioclavicular joint. We attempted to correctly reconstruct the anatomy of the coracoclavicular ligaments under arthroscopy, and describe the minimally invasive arthroscopic procedure. There were 22 patients; mean age at surgery, 38.1 years. Mean time to surgery was 13.2 days. Mean follow-up was 3 years 2 months. The palmaris longus tendon was excised from the ipsilateral side to replace the conoid ligament, while artificial ligament was used for reconstructing the trapezoid ligament. Both ligament reconstructions were performed arthroscopically. No temporary fixation of the acromioclavicular joint was performed. On postoperative radiographic evaluation, 4 patients showed subluxation and 2 showed dislocation of the acromioclavicular joint; the other 16 patients had maintained reduction at the final consultation. MR images 1year after surgery clearly revealed the reconstructed ligaments in 19 patients. Only 1 patient showed osteoarthritis of the acromioclavicular joint. Although it requires resection of the ipsilateral palmaris longus for grafting, we believe that anatomic reconstruction of both coracoclavicular ligaments best restores the function of the acromioclavicular joint. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Organisational Structure and Information Technology (IT): Exploring the Implications of IT for Future Military Structures

    DTIC Science & Technology

    2006-07-01

    4 Abbreviations AI Artificial Intelligence AM Artificial Memory CAD Computer Aided...memory (AM), artificial intelligence (AI), and embedded knowledge systems it is possible to expand the “effective span of competence” of...Technology J Joint J2 Joint Intelligence J3 Joint Operations NATO North Atlantic Treaty Organisation NCW Network Centric Warfare NHS National Health

  15. The use of synthetic ligaments in the design of an enhanced stability total knee joint replacement.

    PubMed

    Stokes, Michael D; Greene, Brendan C; Pietrykowski, Luke W; Gambon, Taylor M; Bales, Caroline E; DesJardins, John D

    2018-03-01

    Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.

  16. Innate Immunity Sensors Participating in Pathophysiology of Joint Diseases: A Brief Overview

    PubMed Central

    Gallo, Jiri; Raska, Milan; Konttinen, Yrjö T.; Nich, Christophe; Goodman, Stuart B.

    2015-01-01

    The innate immune system consists of functionally specialized “modules” that are activated in response to a particular set of stimuli via sensors located on the surface or inside the tissue cells. These cells screen tissues for a wide range of exogenous and endogenous danger/damage-induced signals with the aim to reject or tolerate them and maintain tissue integrity. In this line of thinking, inflammation evolved as an adaptive tool for restoring tissue homeostasis. A number of diseases are mediated by a maladaptation of the innate immune response, perpetuating chronic inflammation and tissue damage. Here, we review recent evidence on the cross talk between innate immune sensors and development of rheumatoid arthritis, osteoarthritis, and aseptic loosening of total joint replacements. In relation to the latter topic, there is a growing body of evidence that aseptic loosening and periprosthetic osteolysis results from long-term maladaptation of periprosthetic tissues to the presence of by-products continuously released from an artificial joint. PMID:25747032

  17. An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles

    PubMed Central

    Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake

    2005-01-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019

  18. Advanced Fabrication Techniques for Precisely Controlled Micro and Nano Scale Environments for Complex Tissue Regeneration and Biomedical Applications

    NASA Astrophysics Data System (ADS)

    Holmes, Benjamin

    As modern medicine advances, it is still very challenging to cure joint defects due to their poor inherent regenerative capacity, complex stratified architecture, and disparate biomechanical properties. The current clinical standard for catastrophic or late stage joint degradation is a total joint implant, where the damaged joint is completely excised and replaced with a metallic or artificial joint. However, these procedures still only lasts for 10-15 years, and there are hosts of recovery complications which can occur. Thus, these studies have sought to employ advanced biomaterials and scaffold fabricated techniques to effectively regrow joint tissue, instead of merely replacing it with artificial materials. We can hypothesize here that the inclusion of biomimetic and bioactive nanomaterials with highly functional electrospun and 3D printed scaffold can improve physical characteristics (mechanical strength, surface interactions and nanotexture) enhance cellular growth and direct stem cell differentiation for bone, cartilage and vascular growth as well as cancer metastasis modeling. Nanomaterial inclusion and controlled 3D printed features effectively increased nano surface roughness, Young's Modulus and provided effective flow paths for simulated arterial blood. All of the approaches explored proved highly effective for increasing cell growth, as a result of increasing micro-complexity and nanomaterial incorporation. Additionally, chondrogenic and osteogenic differentiation, cell migration, cell to cell interaction and vascular formation were enhanced. Finally, growth-factor(gf)-loaded polymer nanospheres greatly improved vascular cell behavior, and provided a highly bioactive scaffold for mesenchymal stem cell (MSC) and human umbilical vein endothelial cell (HUVEC) co-culture and bone formation. In conclusion, electrospinning and 3D printing when combined effectively with biomimetic and bioactive nanomaterials (i.e. carbon nanomaterials, collagen, nHA, polymer drug delivery nanospheres) can provide high performance, functional materials that also serve as effective tissue forming 3D environments. Both general science knowledge and the translational potential of tissue engineered constructs were advanced by original contributions to the fields for tissue engineering and orthopedic medicine. The most original advancement of general science comes from a successful combination of advanced nanomaterials and biomaterials with existing 3D printing and CAD design to support multiple types of cells and tissues. Future translation of these technologies was advanced due to the highly functional nature of these constructs (i.e. mechanical and hydrodynamic characteristics). Future work would involve more evaluation of vascular neogenesis, small animal models to evaluate bioactivity and biocompatibility and large clinically relevant animals to measure gross tissue formation and biomechanical performance.

  19. In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: A pilot study using open-MRI.

    PubMed

    De Coninck, Tineke; Elsner, Jonathan J; Linder-Ganz, Eran; Cromheecke, Michiel; Shemesh, Maoz; Huysse, Wouter; Verdonk, René; Verstraete, Koenraad; Verdonk, Peter

    2014-09-01

    In this pilot study we wanted to evaluate the kinematics of a knee implanted with an artificial polycarbonate-urethane meniscus device, designed for medial meniscus replacement. The static kinematic behavior of the implant was compared to the natural medial meniscus of the non-operated knee. A second goal was to evaluate the motion pattern, the radial displacement and the deformation of the meniscal implant. Three patients with a polycarbonate-urethane implant were included in this prospective study. An open-MRI was used to track the location of the implant during static weight-bearing conditions, within a range of motion of 0° to 120° knee flexion. Knee kinematics were evaluated by measuring the tibiofemoral contact points and femoral roll-back. Meniscus measurements (both natural and artificial) included anterior-posterior meniscal movement, radial displacement, and meniscal height. No difference (P>0.05) was demonstrated in femoral roll-back and tibiofemoral contact points during knee flexion between the implanted and the non-operated knees. Meniscal measurements showed no significant difference in radial displacement and meniscal height (P>0.05) at all flexion angles, in both the implanted and non-operated knees. A significant difference (P ≤ 0.05) in anterior-posterior movement during flexion was observed between the two groups. In this pilot study, the artificial polycarbonate-urethane implant, indicated for medial meniscus replacement, had no influence on femoral roll-back and tibiofemoral contact points, thus suggesting that the joint maintains its static kinematic properties after implantation. Radial displacement and meniscal height were not different, but anterior-posterior movement was slightly different between the implant and the normal meniscus. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Replacement of long segments of the esophagus with a collagen-silicone composite tube.

    PubMed

    Takimoto, Y; Nakamura, T; Teramachi, M; Kiyotani, T; Shimizu, Y

    1995-01-01

    Artificial esophagi designed thus far can be classified into three types in terms of the materials used: natural, artificial, and composite. In conventional models, even when artificial esophagi were made of ideal materials with high tissue affinity, they remained in the tissue as a foreign body, and therefore were not free of the complications caused by implanted material. The authors have designed a new type of artificial esophagus composed of a Silicone tube covered with nonantigenic collagen. The novel feature of this artificial esophagus is that the prosthesis does not remain in the implanted site, but is replaced by regenerated host tissue. Using this artificial esophagus, the authors have already succeeded in replacing a 5 cm gap in the esophagus. In this study, replacement of longer portions of the esophagus was assessed in seven dogs using a 10 cm long artificial esophagus. Stenosis did not occur in five of the seven dogs and, consequently, these dogs survived by oral feeding alone for more than 6 months without dry weight loss. The other two animals died of anesthetic accidents at the time of stent removal 6 weeks after surgery. In both cases, the internal surface of the neoesophagus was covered with a polylayer of squamous epithelium. Regenerated esophagi had normal esophageal glands and immature muscle tissue. It is therefore concluded that this new artificial esophagus is also applicable for replacement of long segments of esophagus.

  1. Analytical and finite element performance evaluation of embedded piezoelectric sensors in polyethylene

    NASA Astrophysics Data System (ADS)

    Safaei, Mohsen; Anton, Steven R.

    2017-04-01

    A common application of piezoelectric transducers is to obtain operational data from working structures and dynamic components. Collected data can then be used to evaluate dynamic characterization of the system, perform structural health monitoring, or implement various other assessments. In some applications, piezoelectric transducers are bonded inside the host structure to satisfy system requirements; for example, piezoelectric transducers can be embedded inside the biopolymers of total joint replacements to evaluate the functionality of the artificial joint. The interactions between the piezoelectric device (inhomogeneity) and the surrounding polymer matrix determine the mechanical behavior of the matrix and the electromechanical behavior of the sensor. In this work, an analytical approach is employed to evaluate the electromechanical performance of 2-D plane strain piezoelectric elements of both circular and rectangular-shape inhomogeneities. These piezoelectric elements are embedded inside medical grade ultra-high molecular weight (UHMW) polyethylene, a material commonly used for bearing surfaces of joint replacements, such as total knee replacements (TKRs). Using the famous Eshelby inhomogeneity solution, the stress and electric field inside the circular (elliptical) inhomogeneity is obtained by decoupling the solution into purely elastic and dielectric systems of equations. For rectangular (non-elliptical) inhomogeneities, an approximation method based on the boundary integral function is utilized and the same decoupling method is employed. In order to validate the analytical result, a finite element analysis is performed for both the circular and rectangular inhomogeneities and the error for each case is calculated. For elliptical geometry, the error is less than 1% for stress and electric fields inside and outside the piezoelectric inhomogeneity, whereas, the error for non-elliptical geometry is obtained as 11% and 7% for stress and electric field inside the inhomogeneity, respectively.

  2. Hierarchical Structure of Articular Bone-Cartilage Interface and Its Potential Application for Osteochondral Tissue Engineering

    NASA Astrophysics Data System (ADS)

    Bian, Weiguo; Qin, Lian; Li, Dichen; Wang, Jin; Jin, Zhongmin

    2010-09-01

    The artificial biodegradable osteochondral construct is one of mostly promising lifetime substitute in the joint replacement. And the complex hierarchical structure of natural joint is important in developing the osteochondral construct. However, the architecture features of the interface between cartilage and bone, in particular those at the micro-and nano-structural level, remain poorly understood. This paper investigates these structural data of the cartilage-bone interface by micro computerized tomography (μCT) and Scanning Electron Microscope (SEM). The result of μCT shows that important bone parameters and the density of articular cartilage are all related to the position in the hierarchical structure. The conjunctions of bone and cartilage were defined by SEM. All of the study results would be useful for the design of osteochondral construct further manufactured by nano-tech. A three-dimensional model with gradient porous structure is constructed in the environment of Pro/ENGINEERING software.

  3. An evaluation of information on the Internet of a new device: the lumbar artificial disc replacement.

    PubMed

    Garcia, Ryan M; Messerschmitt, Patrick J; Ahn, Nicholas U

    2009-02-01

    An analysis of websites, accessible to the public, was conducted pertaining to the lumbar artificial disc replacement. The objective was to investigate the content of information available on the Internet pertaining to the lumbar artificial disc replacement. The Internet is widely used by patients as an educational tool for health care information. Additionally, the Internet is used as a medium for direct-to-consumer marketing. Recent approval of the lumbar artificial disc replacement has led to the emergence of numerous websites offering information about this procedure. It is thought that patients can be influenced by information found on the Internet; therefore, it is imperative that this information be accurate and as complete as possible. Three commonly used search engines were used to locate 105 (35/search engine) websites providing information about the lumbar artificial disc replacement. Each website was evaluated with regard to authorship and content. Fifty-nine percent of the websites reviewed were authorized by a private physician group, 9% by an academic physician group, 6% by industry, 11% were news reports, and 15% were not otherwise categorized. Seventy-two percent offered a mechanism for direct contact and 30% provided clear patient selection criteria. Benefits were expressed in 87% of websites, whereas associated risks were described in 28% or less. European experiences were noted in 53%, whereas only 22% of websites detailed the current US experience. The results of this study demonstrate that much of the content of Internet-derived information pertaining to the lumbar artificial disc replacement is potentially misleading. Until long-term data are available, patients should be cautioned when using the Internet as a source for health care information, particularly with regard to the lumbar artificial disc replacement.

  4. Influence of thermofixation on artificial ACL ligament dimensional and mechanical properties

    NASA Astrophysics Data System (ADS)

    Ben Abdessalem, S.; Jedda, H.; Skhiri, S.; Karray, S.; Dahmen, J.; Boughamoura, H.

    2005-11-01

    The anterior cruciate ligament (ACL) is the major articular ligamentous structure of the knee, it functions as a joint stabilizer. When ruptured, the natural ACL ligament can be replaced by a textile synthetic ligament such as a braid, knitted cord, or woven cord. Theses structures are composed of biocompatible materials such as polyester or Gore-Tex filaments. The success of an ACL replacement is widely linked to its mechanical and dimensional properties such as tensile strength, dimensional stability and resistance to abrasion. We introduced an additional treatment in the manufacturing of textile ACL ligaments based on the thermofixation of the textile structure by using textile industry stabilization techniques. Boiling water, saturated vapor and dry heat have been tested to stabilize a braided ligament made of Dacron polyester. The application of these three techniques led to shrinkage and an increase of breaking strength of the textile structure.

  5. Biotribology of artificial hip joints

    PubMed Central

    Di Puccio, Francesca; Mattei, Lorenza

    2015-01-01

    Hip arthroplasty can be considered one of the major successes of orthopedic surgery, with more than 350000 replacements performed every year in the United States with a constantly increasing rate. The main limitations to the lifespan of these devices are due to tribological aspects, in particular the wear of mating surfaces, which implies a loss of matter and modification of surface geometry. However, wear is a complex phenomenon, also involving lubrication and friction. The present paper deals with the tribological performance of hip implants and is organized in to three main sections. Firstly, the basic elements of tribology are presented, from contact mechanics of ball-in-socket joints to ultra high molecular weight polyethylene wear laws. Some fundamental equations are also reported, with the aim of providing the reader with some simple tools for tribological investigations. In the second section, the focus moves to artificial hip joints, defining materials and geometrical properties and discussing their friction, lubrication and wear characteristics. In particular, the features of different couplings, from metal-on-plastic to metal-on-metal and ceramic-on-ceramic, are discussed as well as the role of the head radius and clearance. How friction, lubrication and wear are interconnected and most of all how they are specific for each loading and kinematic condition is highlighted. Thus, the significant differences in patients and their lifestyles account for the high dispersion of clinical data. Furthermore, such consideration has raised a new discussion on the most suitable in vitro tests for hip implants as simplified gait cycles can be too far from effective implant working conditions. In the third section, the trends of hip implants in the years from 2003 to 2012 provided by the National Joint Registry of England, Wales and Northern Ireland are summarized and commented on in a discussion. PMID:25621213

  6. The Joint Tactical Aerial Resupply Vehicle Impact on Sustainment Operations

    DTIC Science & Technology

    2017-06-09

    Artificial Intelligence , Sustainment Operations, Rifle Company, Autonomous Aerial Resupply, Joint Tactical Autonomous Aerial Resupply System 16...Integrations and Development System AI Artificial Intelligence ARCIC Army Capabilities Integration Center ARDEC Armament Research, Development and...semi- autonomous systems, and fully autonomous systems. Autonomy of machines depends on sophisticated software, including Artificial Intelligence

  7. Medical Surveillance Monthly Report (MSMR). Volume 22, Number 5, May 2015

    DTIC Science & Technology

    2015-05-01

    aTotal column equals one joint replacement per person per period. bAn individual could be counted once in each of the types of joint replacements. cRate...Percentages of joint replace- ment cases who remained in service or had left service, 2 years post-joint replacement, by gender , active component...Musculoskeletal-related disability in US Army personnel: prevalence, gender and military occupational specialties. J Occup Environ Med. 1997;39(1):68–78

  8. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    PubMed

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  9. A study of lubrication, processing conditions, and material combinations that affect the wear of micro-textured-carbide coated cobalt-chromium-molybdenum alloy surfaces used for artificial joints implants

    NASA Astrophysics Data System (ADS)

    Ettienne-Modeste, Geriel A.

    Total joint replacement remains one of the most successful treatments for arthritis. The most common materials used for artificial joints are metals (e.g., cobalt-chrome alloys or titanium alloys), which articulate against ultra-high molecular weight polyethylene. Wear related failures of artificial joints may be reduced with the use of novel micro-textured carbide surfaces. The micro-textured carbide surfaces were deposited on a CoCrMo alloy using microwave plasma-assisted chemical vapor deposition. Wear tests were conducted to determine wear mechanisms and properties of the micro-textured surfaces. The research presented in this thesis addresses: (1) rheolgoical behavior of bovine calf serum with and without antibacterial agents to determine whether they can be used as appropriate models for synovial fluid, (2) the wear behavior of the micro-textured CoCrMo surface system, and (3) the mechanical and material properties of the micro-textured CoCrMo alloy surface relevant to wear performance. The rheological studies showed that the apparent viscosity of bovine calf serum increased with an increase in concentration before and after the serum was used for wear testing. The wear analysis showed that the processing conditions (2hr deposition vs. 4hr deposition times) affected the wear properties. The 2hr carbide-on-carbide lubricated in 50% BCS produced the lowest wear factor and rate for the five wear couple systems containing the carbide disk or plate material. Greater wear was produced in serum without penicillin/streptomycin (P/S) compared to the serum containing P/S. A greater carbide coating thickness 10 (micrometers) was produced during the 4hr deposition time than for the 2hr deposition (˜3mum). The nano-hardness value was higher than the micro-hardness for both the 4hr and 2hr carbide surfaces. The micro-hardness results of the worn carbide surfaces showed that an increase in BCS concentration from 0% to 100% increased the micro-hardness (HV) for carbide surfaces (from 873 to 1344 HV).

  10. Case-Based Planning: An Integrated Theory of Planning, Learning and Memory

    DTIC Science & Technology

    1986-10-01

    rtvoeoo oldo II nocomtmry and Idonltly by block numbor) planning Case-based reasoning learning Artificial Intelligence 20. ABSTRACT (Conllnum...Computational Model of Analogical Prob- lem Solving, Proceedings of the Seventh International Joint Conference on Artificial Intelligence ...Understanding and Generalizing Plans., Proceedings of the Eight Interna- tional Joint Conference on Artificial Intelligence , IJCAI, Karlsrhue, Germany

  11. Musculoskeletal disease burden of hereditary hemochromatosis.

    PubMed

    Sahinbegovic, Enijad; Dallos, Tomáš; Aigner, Elmar; Axmann, Roland; Manger, Bernhard; Englbrecht, Matthias; Schöniger-Hekele, Maximilian; Karonitsch, Thomas; Stamm, Tanja; Farkas, Martin; Karger, Thomas; Stölzel, Ulrich; Keysser, Gernot; Datz, Christian; Schett, Georg; Zwerina, Jochen

    2010-12-01

    To determine the prevalence, clinical picture, and disease burden of arthritis in patients with hereditary hemochromatosis. In this cross-sectional observational study of 199 patients with hemochromatosis and iron overload, demographic and disease-specific variables, genotype, and organ involvement were recorded. The prevalence, intensity, and localization of joint pain were assessed, and a complete rheumatologic investigation was performed. Radiographs of the hands, knees, and ankles were scored for joint space narrowing, erosions, osteophytes, and chondrocalcinosis. In addition, the number and type of joint replacement surgeries were recorded. Joint pain was reported by 72.4% of the patients. Their mean ± SD age at the time of the initial joint symptoms was 45.8 ± 13.2 years. If joint pain was present, it preceded the diagnosis of hemochromatosis by a mean ± SD of 9.0 ± 10.7 years. Bony enlargement was observed in 65.8% of the patients, whereas synovitis was less common (13.6%). Joint space narrowing and osteophytes as well as chondrocalcinosis of the wrist and knee joints were frequent radiographic features of hemochromatosis. Joint replacement surgery was common, with 32 patients (16.1%) undergoing total joint replacement surgery due to severe OA. The mean ± SD age of these patients was 58.3 ± 10.4 years at time of joint replacement surgery. Female sex, metacarpophalangeal joint involvement, and the presence of chondrocalcinosis were associated with a higher risk of early joint failure (i.e., the need for joint replacement surgery). Arthritis is a frequent, early, and severe symptom of hemochromatosis. Disease is not confined to involvement of the metacarpophalangeal joints and often leads to severe damage requiring the replacement of joints. Copyright © 2010 by the American College of Rheumatology.

  12. Hip or knee replacement - after - what to ask your doctor

    MedlinePlus

    ... chap 7. Read More Hip joint replacement Hip pain Knee joint replacement Knee pain Osteoarthritis Patient Instructions Getting your home ready - knee or hip surgery Hip or knee replacement - before - ...

  13. Hip or knee replacement - before - what to ask your doctor

    MedlinePlus

    ... chap 7. Read More Hip joint replacement Hip pain Knee joint replacement Knee pain Osteoarthritis Patient Instructions Getting your home ready - knee or hip surgery Hip or knee replacement - after - ...

  14. Medicare Program; Comprehensive Care for Joint Replacement Payment Model for Acute Care Hospitals Furnishing Lower Extremity Joint Replacement Services. Final rule.

    PubMed

    2015-11-24

    This final rule implements a new Medicare Part A and B payment model under section 1115A of the Social Security Act, called the Comprehensive Care for Joint Replacement (CJR) model, in which acute care hospitals in certain selected geographic areas will receive retrospective bundled payments for episodes of care for lower extremity joint replacement (LEJR) or reattachment of a lower extremity. All related care within 90 days of hospital discharge from the joint replacement procedure will be included in the episode of care. We believe this model will further our goals in improving the efficiency and quality of care for Medicare beneficiaries with these common medical procedures.

  15. What makes patients aware of their artificial knee joint?

    PubMed

    Loth, F L; Liebensteiner, M C; Giesinger, J M; Giesinger, K; Bliem, H R; Holzner, B

    2018-01-08

    Joint awareness was recently introduced as a new concept for outcome assessment after total knee arthroplasty (TKA). Findings from qualitative and psychometric studies suggest that joint awareness is a distinct concept especially relevant to patients with good surgical outcome and patients at late follow-up time points. The aim of this study was to improve the understanding of the concept of joint awareness by identifying situations in which patients are aware of their artificial knee joint and to investigate what bodily sensations and psychological factors raise a patient's awareness of her/his knee. In addition, we evaluated the relative importance of patient-reported outcome parameters that are commonly assessed in orthopaedics. Qualitative interviews were conducted with patients being at least 12 months after TKA. The interviews focused on when, where and for what reasons patients were aware of their artificial knee joint. To evaluate the relative importance of 'joint awareness' after TKA among nine commonly assessed outcome parameters (e.g. pain or stiffness), we collected importance ratings ('0' indicating no importance at all and '10' indicating high importance). We conducted interviews with 40 TKA patients (mean age 69.0 years; 65.0% female). Joint awareness was found to be frequently triggered by kneeling on the floor (30%), climbing stairs (25%), and starting up after resting (25%). Patients reported joint awareness to be related to activities of daily living (68%), specific movements (60%), or meteoropathy (18%). Sensations causing joint awareness included pain (45%) or stiffness (15%). Psychological factors raising a patient's awareness of his/her knee comprised for example feelings of insecurity (15%), and fears related to revision surgeries, inflammations or recurring pain (8%). Patients' importance ratings of outcome parameters were generally high and did not allow differentiating clearly among them. We have identified a wide range of situations, activities, movements and psychological factors contributing to patients' awareness of their artificial knee joints. This improves the understanding of the concept of joint awareness and of a patient's perception of his/her artificial knee joint. The diversity of sensations and factors raising patient's awareness of their joint encourages taking a broader perspective on outcome after TKA.

  16. [Endoprostheses in geriatric traumatology].

    PubMed

    Buecking, B; Eschbach, D; Bliemel, C; Knobe, M; Aigner, R; Ruchholtz, S

    2017-01-01

    Geriatric traumatology is increasing in importance due to the demographic transition. In cases of fractures close to large joints it is questionable whether primary joint replacement is advantageous compared to joint-preserving internal fixation. The aim of this study was to describe the importance of prosthetic joint replacement in the treatment of geriatric patients suffering from frequent periarticular fractures in comparison to osteosynthetic joint reconstruction and conservative methods. A selective search of the literature was carried out to identify studies and recommendations concerned with primary arthroplasty of fractures in the region of the various joints (hip, shoulder, elbow and knee). The importance of primary arthroplasty in geriatric traumatology differs greatly between the various joints. Implantation of a prosthesis has now become the gold standard for displaced fractures of the femoral neck. In addition, reverse shoulder arthroplasty has become an established alternative option to osteosynthesis in the treatment of complex proximal humeral fractures. Due to a lack of large studies definitive recommendations cannot yet be given for fractures around the elbow and the knee. Nowadays, joint replacement for these fractures is recommended only if reconstruction of the joint surface is not possible. The importance of primary joint replacement for geriatric fractures will probably increase in the future. Further studies with larger patient numbers must be conducted to achieve more confidence in decision making between joint replacement and internal fixation especially for shoulder, elbow and knee joints.

  17. High-Level Vision and Planning Workshop Proceedings

    DTIC Science & Technology

    1989-08-01

    Correspondence in Line Drawings of Multiple View-. In Proc. of 8th Intern. Joint Conf. on Artificial intellignece . 1983. [63] Tomiyasu, K. Tutorial...joint U.S.-Israeli workshop on artificial intelligence are provided in this Institute for Defense Analyses document. This document is based on a broad...participants is provided along with applicable references for individual papers. 14. SUBJECT TERMS 15. NUMBER OF PAGES Artificial Intelligence; Machine Vision

  18. 77 FR 59082 - Drawbridge Operation Regulation; Atlantic Intracoastal Waterway (AIWW), Elizabeth River, Southern...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-26

    ... Chesapeake, VA. This deviation is necessary to facilitate replacing lift joints on the Norfolk Southern 7... accommodate lift joint replacement. Under the current operating schedule the bridge shall be left in the open.... To facilitate lift joint replacement, the drawbridge will be maintained in the closed-to-navigation...

  19. Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

    PubMed Central

    2012-01-01

    Background Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. Methods We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. Results During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. Conclusions Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding. PMID:22704638

  20. Hip joint replacement - slideshow

    MedlinePlus

    ... this page: //medlineplus.gov/ency/presentations/100006.htm Hip joint replacement - series—Normal anatomy To use the ... to slide 5 out of 5 Overview The hip joint is made up of two major parts: ...

  1. Active Ambiguity Reduction: An Experiment Design Approach to Tractable Qualitative Reasoning.

    DTIC Science & Technology

    1987-04-20

    Approach to Tractable Qualitative Reasoning Shankar A. Rajamoney t [ For Gerald F. DeJong Artificial Intelligence Research Group Coordinated Science...Representations of Knowledge in a Mechanics Problem- Solver." Proceedings of the Fifth International Joint Conference on Artificial Intelligence. Cambridge. MIA...International Joint Conference on Artificial Intelligence. Tokyo. Japan. 1979. [de Kleer84] J. de Kleer and J. S. Brown. "A Qualitative Physics Based on

  2. Tribological performance of the biological components of synovial fluid in artificial joint implants

    NASA Astrophysics Data System (ADS)

    Ghosh, Subir; Choudhury, Dipankar; Roy, Taposh; Moradi, Ali; Masjuki, H. H.; Pingguan-Murphy, Belinda

    2015-08-01

    The concentration of biological components of synovial fluid (such as albumin, globulin, hyaluronic acid, and lubricin) varies between healthy persons and osteoarthritis (OA) patients. The aim of the present study is to compare the effects of such variation on tribological performance in a simulated hip joint model. The study was carried out experimentally by utilizing a pin-on-disk simulator on ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoP) hip joint implants. The experimental results show that both friction and wear of artificial joints fluctuate with the concentration level of biological components. Moreover, the performance also varies between material combinations. Wear debris sizes and shapes produced by ceramic and polyethylene were diverse. We conclude that the biological components of synovial fluid and their concentrations should be considered in order to select an artificial hip joint to best suit that patient.

  3. Managed care and critical pathway development: the joint replacement experience.

    PubMed

    Benham, A J

    1999-01-01

    This article examines the economic, social, ethical, and political issues affecting total joint replacement patients in a managed care environment. Using general systems theory as a framework, it examines the interrelated historical events that have shaped the development of both joint replacement procedures and managed care, and discusses the extent to which these two phenomena have been mutually influential. Specifically, the article examines the initial development, implementation, and continuing evolution of clinical pathways as an easily identified and relatively discrete manifestation of managed care for the joint replacement population. While the overall impact of managed care is beyond the scope of this presentation, it is hoped that a focus on the practical application of clinical pathways to joint replacement will allow some general principles to emerge that may be useful for both patients and practitioners operating in other aspects of the managed care environment.

  4. [Orthopedic surgical implants and allergies. Joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)].

    PubMed

    Thomas, P; Schuh, A; Ring, J; Thomsen, M

    2008-03-01

    Materials used in osteosynthesis or artificial joint replacement are usually well tolerated. Complaints after such operations are mostly related to infection or mechanical problems but may also be caused by allergic reactions. The latter encompass skin changes, e.g., eczema, delayed wound/bone healing, recurrent effusion, pain, or implant loosening. In contrast to the high incidence of cutaneous metal contact allergy, allergies associated with implants are a rare condition. However, epidemiological data on the incidence of implant-related allergic reactions are still missing. Typical elicitors are nickel, chromium, cobalt, and constituents of bone cement (acrylates und additives such as gentamicin or benzoyl peroxide). After exclusion of the most common differential diagnoses, allergy diagnostic procedures are primarily based on patch tests including a metal and bone cement component series. Additional analysis of periimplant tissue is recommended. However, further studies are necessary to show the significance of the histologic findings and the role of the lymphocyte transformation test (LTT). Which combinations of factors will induce allergic sensitization to implants or trigger periimplant allergic reactions in the case of preexisting cutaneous metal allergy is still unknown. Titanium-based osteosynthesis materials are recommended for metal allergic patients. In elective hip replacements, a ceramic/polyethylene (PE) articulation should be used, and in knee replacements "alternative materials". If a regular, potentially applicable CoCr/PE articulation is preferred, the patient must be well informed and must give his/her written consent.

  5. Diabetes is associated with persistent pain after hip and knee replacement

    PubMed Central

    Rajamäki, Tuomas J; Jämsen, Esa; Puolakka, Pia A; Nevalainen, Pasi I; Moilanen, Teemu

    2015-01-01

    Background and purpose In some patients, for unknown reasons pain persists after joint replacement, especially in the knee. We determined the prevalence of persistent pain following primary hip or knee replacement and its association with disorders of glucose metabolism, metabolic syndrome (MetS), and obesity. Patients and methods The incidence of pain in the operated joint was surveyed 1–2 years after primary hip replacement (74 patients (4 bilateral)) or primary knee replacement (119 patients (19 bilateral)) in 193 osteoarthritis patients who had participated in a prospective study on perioperative hyperglycemia. Of the 155 patients who completed the survey, 21 had undergone further joint replacement surgery during the follow-up and were excluded, leaving 134 patients for analysis. Persistent pain was defined as daily pain in the operated joint that had lasted over 3 months. Factors associated with persistent pain were evaluated using binary logistic regression with adjustment for age, sex, and operated joint. Results 49 of the134 patients (37%) had a painful joint and 18 of them (14%) had persistent pain. A greater proportion of knee patients than hip patients had a painful joint (46% vs. 24%; p = 0.01) and persistent pain (20% vs. 4%; p = 0.007). Previously diagnosed diabetes was strongly associated with persistent pain (5/19 vs. 13/115 in those without; adjusted OR = 8, 95% CI: 2–38) whereas MetS and obesity were not. However, severely obese patients (BMI ≥ 35) had a painful joint (but not persistent pain) more often than patients with BMI < 30 (14/21 vs. 18/71; adjusted OR = 5, 95% CI: 2–15). Interpretation Previously diagnosed diabetes is a risk factor for persistent pain in the operated joint 1–2 years after primary hip or knee replacement. PMID:25953426

  6. Health Information in Bosnian (bosanski)

    MedlinePlus

    ... new window. A Expand Section After Surgery Home Care After Total Joint Replacement - bosanski (Bosnian) Bilingual PDF Health Information ... Information Translations J Expand Section Joint Disorders Home Care After Total Joint Replacement - bosanski (Bosnian) Bilingual PDF Health Information ...

  7. Management of the patient with a total joint replacement: the primary care practitioner's role.

    PubMed

    Palmer, L M

    1999-01-01

    The primary care practitioner assumes chief responsibility for patients with arthritis. More than 40 million Americans experience some form of arthritis. Management of the patient with arthritis may include a referral to an orthopedic surgeon for surgical intervention. As estimated, up to 500,000 total joint replacement procedures are performed by orthopedic surgeons each year in the United States. Presurgical evaluation for a total joint replacement is imperative to ensure that the patient can safely undergo this surgical procedure. Postsurgical care of a patient with total joint replacement involves coordinating care with the physical therapist and orthopedic surgeon to ensure adequate follow-through with the recommended rehabilitation program, prophylactic antibiotic coverage, and observation for any complications including infection, deep-vein thrombosis, or loosening of the total-joint prosthesis.

  8. Perspective on the Ongoing Replacement of Artificial and Animal-Based Dyes with Alternative Natural Pigments in Foods and Beverages.

    PubMed

    Schweiggert, Ralf M

    2018-03-28

    This perspective highlights current trends, advances, and challenges related to the replacement of artificial dyes and the insect-based carmine with alternative natural pigments. Briefly reviewing the history of food coloration, key publications and public events leading to diverse concerns about artificial dyes and carmine will be summarized. An overview about promising alternatives in the market and those under development is provided, including a separate section on coloring foodstuffs. The perspective aims at supporting readers to keep abreast with the enormous efforts undertaken by the food and beverage industry to replace certain food dyes.

  9. Redesigning a joint replacement program using Lean Six Sigma in a Veterans Affairs hospital.

    PubMed

    Gayed, Benjamin; Black, Stephen; Daggy, Joanne; Munshi, Imtiaz A

    2013-11-01

    In April 2009, an analysis of joint replacement surgical procedures at the Richard L. Roudebush Veterans Affairs Medical Center, Indianapolis, Indiana, revealed that total hip and knee replacements incurred $1.4 million in non-Veterans Affairs (VA) care costs with an average length of stay of 6.1 days during fiscal year 2008. The Joint Replacement Program system redesign project was initiated following the Vision-Analysis-Team-Aim-Map-Measure-Change-Sustain (VA-TAMMCS) model to increase efficiency, decrease length of stay, and reduce non-VA care costs. To determine the effectiveness of Lean Six Sigma process improvement methods applied in a VA hospital. Perioperative processes for patients undergoing total joint replacement were redesigned following the VA-TAMMCS model--the VA's official, branded method of Lean Six Sigma process improvement. A multidisciplinary team including the orthopedic surgeons, frontline staff, and executive management identified waste in the current processes and initiated changes to reduce waste and increase efficiency. Data collection included a 1-year baseline period and a 20-month sustainment period. The primary endpoint was length of stay; a secondary analysis considered non-VA care cost reductions. Length of stay decreased 36% overall, decreasing from 5.3 days during the preproject period to 3.4 days during the 20-month sustainment period (P < .001). Non-VA care was completely eliminated for patients undergoing total hip and knee replacement at the Richard L. Roudebush Veterans Affairs Medical Center, producing an estimated return on investment of $1 million annually when compared with baseline cost and volumes. In addition, the volume of total joint replacements at this center increased during the data collection period. The success of the Joint Replacement Program demonstrates that VA-TAMMCS is an effective tool for Lean and Six Sigma process improvement initiatives in a surgical practice, producing a 36% sustained reduction in length of stay and completely eliminating non-VA care for total hip and knee replacements while increasing total joint replacement volume at this medical center.

  10. The effect of local anaesthetic wound infiltration on chronic pain after lower limb joint replacement: A protocol for a double-blind randomised controlled trial

    PubMed Central

    2011-01-01

    Background For the majority of patients with osteoarthritis (OA), joint replacement is a successful intervention for relieving chronic joint pain. However, between 10-30% of patients continue to experience chronic pain after joint replacement. Evidence suggests that a risk factor for chronic pain after joint replacement is the severity of acute post-operative pain. The aim of this randomised controlled trial (RCT) is to determine if intra-operative local anaesthethic wound infiltration additional to a standard anaethesia regimen can reduce the severity of joint pain at 12-months after total knee replacement (TKR) and total hip replacement (THR) for OA. Methods 300 TKR patients and 300 THR patients are being recruited into this single-centre double-blind RCT. Participants are recruited before surgery and randomised to either the standard care group or the intervention group. Participants and outcome assessors are blind to treatment allocation throughout the study. The intervention consists of an intra-operative local anaesthetic wound infiltration, consisting of 60 mls of 0.25% bupivacaine with 1 in 200,000 adrenaline. Participants are assessed on the first 5 days post-operative, and then at 3-months, 6-months and 12-months. The primary outcome is the WOMAC Pain Scale, a validated measure of joint pain at 12-months. Secondary outcomes include pain severity during the in-patient stay, post-operative nausea and vomiting, satisfaction with pain relief, length of hospital stay, joint pain and disability, pain sensitivity, complications and cost-effectiveness. A nested qualitative study within the RCT will examine the acceptability and feasibility of the intervention for both patients and healthcare professionals. Discussion Large-scale RCTs assessing the effectiveness of a surgical intervention are uncommon, particulary in orthopaedics. The results from this trial will inform evidence-based recommendations for both short-term and long-term pain management after lower limb joint replacement. If a local anaesthetic wound infiltration is found to be an effective and cost-effective intervention, implementation into clinical practice could improve long-term pain outcomes for patients undergoing lower limb joint replacement. Trial registration Current Controlled Trials ISRCTN96095682 PMID:21352559

  11. Design and simulation of a cable-pulley-based transmission for artificial ankle joints

    NASA Astrophysics Data System (ADS)

    Liu, Huaxin; Ceccarelli, Marco; Huang, Qiang

    2016-06-01

    In this paper, a mechanical transmission based on cable pulley is proposed for human-like actuation in the artificial ankle joints of human-scale. The anatomy articular characteristics of the human ankle is discussed for proper biomimetic inspiration in designing an accurate, efficient, and robust motion control of artificial ankle joint devices. The design procedure is presented through the inclusion of conceptual considerations and design details for an interactive solution of the transmission system. A mechanical design is elaborated for the ankle joint angular with pitch motion. A multi-body dynamic simulation model is elaborated accordingly and evaluated numerically in the ADAMS environment. Results of the numerical simulations are discussed to evaluate the dynamic performance of the proposed design solution and to investigate the feasibility of the proposed design in future applications for humanoid robots.

  12. A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury

    PubMed Central

    Jiang, JingLe; Marathe, Amar R.; Keene, Jennifer C.; Taylor, Dawn M.

    2016-01-01

    Background Custom-fitted skull replacement pieces are often used after a head injury or surgery to replace damaged bone. Chronic brain recordings are beneficial after injury/surgery for monitoring brain health and seizure development. Embedding electrodes directly in these artificial skull replacement pieces would be a novel, low-risk way to perform chronic brain monitoring in these patients. Similarly, embedding electrodes directly in healthy skull would be a viable minimally-invasive option for many other neuroscience and neurotechnology applications requiring chronic brain recordings. New Method We demonstrate a preclinical testbed that can be used for refining electrode designs embedded in artificial skull replacement pieces or for embedding directly into the skull itself. Options are explored to increase the surface area of the contacts without increasing recording contact diameter to maximize recording resolution. Results Embedding electrodes in real or artificial skull allows one to lower electrode impedance without increasing the recording contact diameter by making use of conductive channels that extend into the skull. The higher density of small contacts embedded in the artificial skull in this testbed enables one to optimize electrode spacing for use in real bone. Comparison with Existing Methods For brain monitoring applications, skull-embedded electrodes fill a gap between electroencephalograms recorded on the scalp surface and the more invasive epidural or subdural electrode sheets. Conclusions Embedding electrodes into the skull or in skull replacement pieces may provide a safe, convenient, minimally-invasive alternative for chronic brain monitoring. The manufacturing methods described here will facilitate further testing of skull-embedded electrodes in animal models. PMID:27979758

  13. A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury.

    PubMed

    Jiang, JingLe; Marathe, Amar R; Keene, Jennifer C; Taylor, Dawn M

    2017-02-01

    Custom-fitted skull replacement pieces are often used after a head injury or surgery to replace damaged bone. Chronic brain recordings are beneficial after injury/surgery for monitoring brain health and seizure development. Embedding electrodes directly in these artificial skull replacement pieces would be a novel, low-risk way to perform chronic brain monitoring in these patients. Similarly, embedding electrodes directly in healthy skull would be a viable minimally-invasive option for many other neuroscience and neurotechnology applications requiring chronic brain recordings. We demonstrate a preclinical testbed that can be used for refining electrode designs embedded in artificial skull replacement pieces or for embedding directly into the skull itself. Options are explored to increase the surface area of the contacts without increasing recording contact diameter to maximize recording resolution. Embedding electrodes in real or artificial skull allows one to lower electrode impedance without increasing the recording contact diameter by making use of conductive channels that extend into the skull. The higher density of small contacts embedded in the artificial skull in this testbed enables one to optimize electrode spacing for use in real bone. For brain monitoring applications, skull-embedded electrodes fill a gap between electroencephalograms recorded on the scalp surface and the more invasive epidural or subdural electrode sheets. Embedding electrodes into the skull or in skull replacement pieces may provide a safe, convenient, minimally-invasive alternative for chronic brain monitoring. The manufacturing methods described here will facilitate further testing of skull-embedded electrodes in animal models. Published by Elsevier B.V.

  14. [Review and prospect of analysis on UHMWPE wear debris in artificial hip joints].

    PubMed

    Wu, Jingping; Yuan, Chengqing; Yan, Xinping

    2010-02-01

    This paper briefly reviews the latest progress in the analyses of the technologies for artificial hip joints; and in the researches directed to the features of UHMWPE debris obtained from all kinds of experimental conditions, to the wear process and wear mechanism, and to the factors which influence the wear mechanism. Furthermore, the signification of debris atlas was illustrated. Finally, future directions to be furthered were considered and envisaged. It is suggested that emphases be laid on the relationship between the UHMWPE debris feature and the wear mechanism, and be laid synergistic effects of biochemical environment and loading environment so as to establish the predictive wear models of artificial hip joints.

  15. Continuous Glucose Monitoring

    MedlinePlus

    ... costs will be covered. What is an artificial pancreas? A CGM is one part of the “artificial pancreas” systems that are beginning to reach people with ... has played an important role in developing artificial pancreas technology. An artificial pancreas replaces manual blood glucose ...

  16. Microstructure analysis and wear behavior of titanium cermet femoral head with hard TiC layer.

    PubMed

    Luo, Yong; Ge, Shirong; Liu, Hongtao; Jin, Zhongmin

    2009-12-11

    Titanium cermet was successfully synthesized and formed a thin gradient titanium carbide coating on the surface of Ti6Al4V alloy by using a novel sequential carburization under high temperature, while the titanium cermet femoral head was produced. The titanium cermet phase and surface topography were characterized with X-ray diffraction (XRD) and backscattered electron imaging (BSE). And then the wear behavior of titanium cermet femoral head was investigated by using CUMT II artificial joint hip simulator. The surface characterization indicates that carbon effectively diffused into the titanium alloys and formed a hard TiC layer on the Ti6Al4V alloys surface with a micro-porous structure. The artificial hip joint experimental results show that titanium cermet femoral head could not only improve the wear resistance of artificial femoral head, but also decrease the wear of UHMWPE joint cup. In addition, the carburized titanium alloy femoral head could effectively control the UHMWPE debris distribution, and increase the size of UHMWPE debris. All of the results suggest that titanium cermet is a prospective femoral head material in artificial joint.

  17. [Clinical application of artificial condylar process for reconstructing temporomandibular joint].

    PubMed

    Huang, Xiangdao; Shao, Zhanying; Wang, Fasheng; Duan, Yi

    2012-01-01

    To assess the feasibility and clinical outcomes of artificial condylar process in reconstruction of the temporomandibular joint. Between January 2005 and January 2010, the reconstructions of the temporomandibular joints with artificial condylar process were performed in 10 cases (11 sides, including 7 left sides and 4 right sides). There were 7 males and 3 females with an average age of 50 years (range, 40-68 years). Mandibular condyle defects were caused by mandible tumor in 7 patients with a mean disease duration of 15 months (range, 9-24 months) and by bilateral condylar fractures in 3 patients with the disease duration of 2, 3, and 2 days respectively. According to Neff classification, there were type M and A in 1 case, type M and B in 1 case, and type M in one side and subcondylar fracture in the other side in 1 case. Incisions in all patients healed by first intention, and no complication occurred. All cases were followed up 1 to 4 years, showed facial symmetry and good occluding relation, and the mouth opening was 22-38 mm (mean, 30 mm). No temporomandibular joint clicking or pain and no recurrence of tumor were observed. Most of the artificial condylar process were in good position except 1 deviated from the correct angle slightly. All the patients could have diet normally. The results of temporomandibular joint reconstruction after tumor resection with artificial condylar process are good, but the clinical outcome for intracapsular condylar fracture is expected to be further verified.

  18. Joint Disorders - Multiple Languages

    MedlinePlus

    ... a new window. Arabic (العربية) Expand Section Home Care After Total Joint Replacement - العربية (Arabic) Bilingual PDF Health Information Translations Bosnian (bosanski) Expand Section Home Care After Total Joint Replacement - bosanski (Bosnian) Bilingual PDF Health Information ...

  19. Improving transition of care for veterans after total joint replacement.

    PubMed

    Green, Uthona R; Dearmon, Valorie; Taggart, Helen

    2015-01-01

    Patients transitioning from hospital to home are at risk for readmission to the hospital. Readmissions are costly and occur too often. Standardized discharge education processes have shown to decrease readmissions. The purpose of this quality improvement project was to utilize evidence-based practice changes to decrease 30-day all-cause readmissions after total joint replacement. Review of literature revealed that improved discharge education can decrease unnecessary readmissions after discharge. A quality improvement project was developed including standardized total joint replacement discharge education, teach-back education methodology, and improved postdischarge telephone follow-up. The quality improvement project was initiated and outcomes were evaluated. Improving coordination of the discharge process, enhanced education for patients/caregivers, and postdischarge follow-up decreased total joint replacement readmissions.

  20. STS-111 Flight Day 09 Highlights

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The STS-111 flight crew consists of Kenneth D. Cockrell, Commander, Paul S. Lockhart, Pilot, Franklin R. Chang-Diaz, Mission Specialist, Philippe Perrin, (CNES), Mission Specialist, Valery G. Korzun, (RSA), ISS Up, Peggy A. Whitson, ISS Up , Sergei Y. Treschev (RSC), ISS Up, Yuri I. Onufriyenko (RSA), ISS Down, Carl E. Walz, and Daniel W. Bursch (ISS) Down. The main goal on this ninth day of flight STS-111, is to replace the wrist roll joint of the Robotic Arm on the International Space Station. Live footage of the wrist roll joint replacement is presented. Paul Lockhart is the spacewalk coordinator for this mission. Franklin Chang-Diaz and Philippe Perrin, are responsible for replacing the wrist roll joint and performing maintenance activities. The spacewalk to repair this joint occurs outside the Space Station's Quest Airlock. The wrist roll joint was replaced successfully. The spacewalk took approximately 7 hours and 17 minutes to complete.

  1. Validating Future Force Performance Measures (Army Class): Reclassification Test and Criterion Development

    DTIC Science & Technology

    2009-09-01

    Replace CV boot assembly. 11 Replace propeller shafts , universal joints, and center bearings. 11 Replace front axle spindle . 5 Replace...propeller shafts , universal joints, and center bearings. (SL1/2) 12 Troubleshoot axles. (SL1/2) 11 Replace front axle spindle . (SL1/2) 6...Social Sciences. NOTE: The findings in this report are not to be construed as an official Department of the Army position, unless so designated by

  2. Can combined use of low-level lasers and hyaluronic acid injections prolong the longevity of degenerative knee joints?

    PubMed Central

    Ip, David; Fu, Nga Yue

    2015-01-01

    Background This study evaluated whether half-yearly hyaluronic acid injection together with low-level laser therapy in addition to standard conventional physical therapy can successfully postpone the need for joint replacement surgery in elderly patients with bilateral symptomatic tricompartmental knee arthritis. Methods In this prospective, double-blind, placebo-controlled study, 70 consecutive unselected elderly patients with bilateral tricompartmental knee arthritis were assigned at random to either one of two conservative treatment protocols to either one of the painful knees. Protocol A consisted of conventional physical therapy plus a sham light source plus saline injection, and protocol B consisted of protocol A with addition of half-yearly hyaluronic acid injection as well as low-level laser treatment instead of using saline and a sham light source. Treatment failure was defined as breakthrough pain necessitating joint replacement. Results Among the 140 painful knees treated with either protocol A or protocol B, only one of the 70 painful knees treated by protocol B required joint replacement, whereas 15 of the 70 painful knees treated by protocol A needed joint replacement surgery (P<0.05). Conclusion We conclude that half-yearly hyaluronic acid injections together with low-level laser therapy should be incorporated into the standard conservative treatment protocol for symptomatic knee arthritis, because it may prolong the longevity of the knee joint without the need for joint replacement. PMID:26346122

  3. Qualitative and Quantitative Proofs of Security Properties

    DTIC Science & Technology

    2013-04-01

    Naples, Italy (September 2012) – Australasian Joint Conference on Artifical Intelligence (December 2012). • Causality, Responsibility, and Blame...realistic solution concept, Proceedings of the 21st International Joint Conference on Artificial Intelligence (IJCAI 2009), 2009, pp. 153–158. 17. J...Conference on Artificial Intelligence (AAAI-12), 2012, pp. 1917-1923. 29. J. Y. Halpern and S. Leung, Weighted sets of probabilities and minimax

  4. Impact of the economic downturn on total joint replacement demand in the United States: updated projections to 2021.

    PubMed

    Kurtz, Steven M; Ong, Kevin L; Lau, Edmund; Bozic, Kevin J

    2014-04-16

    Few studies have explored the role of the National Health Expenditure and macroeconomics on the utilization of total joint replacement. The economic downturn has raised questions about the sustainability of growth for total joint replacement in the future. Previous projections of total joint replacement demand in the United States were based on data up to 2003 using a statistical methodology that neglected macroeconomic factors, such as the National Health Expenditure. Data from the Nationwide Inpatient Sample (1993 to 2010) were used with United States Census and National Health Expenditure data to quantify historical trends in total joint replacement rates, including the two economic downturns in the 2000s. Primary and revision hip and knee arthroplasty were identified using codes from the International Classification of Diseases, Ninth Revision, Clinical Modification. Projections in total joint replacement were estimated using a regression model incorporating the growth in population and rate of arthroplasties from 1993 to 2010 as a function of age, sex, race, and census region using the National Health Expenditure as the independent variable. The regression model was used in conjunction with government projections of National Health Expenditure from 2011 to 2021 to estimate future arthroplasty rates in subpopulations of the United States and to derive national estimates. The growth trend for the incidence of joint arthroplasty, for the overall United States population as well as for the United States workforce, was insensitive to economic downturns. From 2009 to 2010, the total number of procedures increased by 6.0% for primary total hip arthroplasty, 6.1% for primary total knee arthroplasty, 10.8% for revision total hip arthroplasty, and 13.5% for revision total knee arthroplasty. The National Health Expenditure model projections for primary hip replacement in 2020 were higher than a previously projected model, whereas the current model estimates for total knee arthroplasty were lower. Economic downturns in the 2000s did not substantially influence the national growth trends for hip and knee arthroplasty in the United States. These latest updated projections provide a basis for surgeons, hospitals, payers, and policy makers to plan for the future demand for total joint replacement surgery.

  5. Modeling and optimization of joint quality for laser transmission joint of thermoplastic using an artificial neural network and a genetic algorithm

    NASA Astrophysics Data System (ADS)

    Wang, Xiao; Zhang, Cheng; Li, Pin; Wang, Kai; Hu, Yang; Zhang, Peng; Liu, Huixia

    2012-11-01

    A central composite rotatable experimental design(CCRD) is conducted to design experiments for laser transmission joining of thermoplastic-Polycarbonate (PC). The artificial neural network was used to establish the relationships between laser transmission joining process parameters (the laser power, velocity, clamp pressure, scanning number) and joint strength and joint seam width. The developed mathematical models are tested by analysis of variance (ANOVA) method to check their adequacy and the effects of process parameters on the responses and the interaction effects of key process parameters on the quality are analyzed and discussed. Finally, the desirability function coupled with genetic algorithm is used to carry out the optimization of the joint strength and joint width. The results show that the predicted results of the optimization are in good agreement with the experimental results, so this study provides an effective method to enhance the joint quality.

  6. Hip joint replacement

    MedlinePlus

    ... Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... total hip replacement surgery in patients with hip osteoarthritis: a long-term follow-up of a randomised ...

  7. Laser textured Co-Cr-Mo alloy stored chitosan/poly(ethylene glycol) composite applied on artificial joints lubrication.

    PubMed

    Lu, Hailin; Ren, Shanshan; Guo, Junde; Li, Yue; Li, Jianhui; Dong, Guangneng

    2017-09-01

    Arthroplasty brings the wear problems because of body fluid has poor performance as lubricant. Lubricant which is used in artificial joints will rapidly degrade and be absorbed by human body after injecting. To prolong the lubricant's effectiveness, this study prepared chitosan/poly(ethylene glycol) (CS/PEG) and textures to play a role in joint lubrication and wear protection. Chitosan (CS) and poly(ethylene glycol) which have biocompatibility and biodegradability properties can be used in human body. The tribological results shown that CS/PEG sol has excellent performance when this sol was composed by 2wt% CS and 30wt% PEG, the average friction coefficient below 0.016 under the condition of 30-90N load (pressure 4.2-12.6MPa). In this study, CS/PEG was added in the texture of artificial joints, then the surfaces of the CS/PEG formed gel via NaOH solidification effect. The CS/PEG gel film could prevent the CS/PEG sol from diluting in body fluid. Meanwhile, FT-IR, XRD, UV/vis and Raman spectra revealed that CS associated with PEG via hydrogen bond effect may form a particular structure, which leaded the good tribological performance. This study provides a new, simple and green approach to enhance tribological performances of artificial joints. Copyright © 2017. Published by Elsevier B.V.

  8. Artificial organs and transplantation.

    PubMed

    Splendiani, G; Cipriani, S; Vega, A; Casciani, C U

    2003-05-01

    Nowadays artificial devices are not able to totally and undefinitely replace the loss of function of all vital organs and artificial organs can be used only to bridge the time to transplantation, which must be considered the first choice in the therapeutical approach for many chronic diseases. Since general population aging process is leading to an increase of organ demand, the gap between performed and requested transplantation is hard to fill. Xenotransplantation is nowadays only an experimental alternative solution and we have to do our best using available artificial organs to increase and improve the survival of patients waiting for transplantation. In this meeting we particularly dealt about organ function replacing therapy, especially regarding the kidney, heart, liver, pancreas and ear.

  9. [A primary application and evaluation of temporomandibular joint replacement with stock prosthesis].

    PubMed

    Zhang, Xiao-hu; Chen, Min-jie; Qiu, Ya-ting; Yang, Chi

    2012-06-01

    To evaluate the effect of total joint replacement in treatment of temporomandibular joint(TMJ) osteoarthropathy with stock prostheses. Six female patients involving 10 joints (2 unilateral and 4 bilateral), with an average age of 59 years old, were involved in this study. Three patients (5 joints) were diagnosed as internal derangement in V stage depending on MRI, 3D-CT findings and clinical characteristics. The other 3 patients (5 joints) had histories of failed temporomandibular joint operation using costochondral graft or temporalis fascial flap. The maximal mouth opening was 1.9 cm on average (range, 1.0 to 2.9cm). All the joints were replaced with Biomet standard prosthesis under general anesthesia. The follow-up period was from 7 to 49 months (average, 17.5 months). All the operations were successfully performed. Heterotopic ossification happened in a bilateral case 1 year postoperatively. One patient with bilateral joint disease complained of severe uncomfortable feeling in the region of the ears and the temples, although there was no significant positive signs according to an ENT examination. Pain relief of the joint and mouth opening improvement were significant in 4 patients. No failure was noted secondary to infection or loosening of the prostheses. The occlusal relationship kept stable postoperatively in all cases. Total TMJ joint replacement with standard prosthesis is a good choice for TMJ reconstruction. It can significantly reduce joint pain and the mouth opening limitation resulted from osteoarthritis. Long-term result remains to be evaluated based on a long-term follow-up.

  10. Chicken scFvs with an Artificial Cysteine for Site-Directed Conjugation

    PubMed Central

    Kim, Soohyun; Kim, Hyori; Chung, Junho

    2016-01-01

    For the site-directed conjugation of chemicals and radioisotopes to the chicken-derived single-chain variable fragment (scFv), we investigated amino acid residues replaceable with cysteine. By replacing each amino acid of the 157 chicken variable region framework residues (FR, 82 residues on VH and 75 on VL) with cysteine, 157 artificial cysteine mutants were generated and characterized. At least 27 residues on VL and 37 on VH could be replaced with cysteine while retaining the binding activity of the original scFv. We prepared three VL (L5, L6 and L7) and two VH (H13 and H16) mutants as scFv-Ckappa fusion proteins and showed that PEG-conjugation to the sulfhydryl group of the artificial cysteine was achievable in all five mutants. Because the charge around the cysteine residue affects the in vivo stability of thiol-maleimide conjugation, we prepared 16 charge-variant artificial cysteine mutants by replacing the flanking residues of H13 with charged amino acids and determined that the binding activity was not affected in any of the mutants except one. We prepared four charge-variant H13 artificial cysteine mutants (RCK, DCE, ECD and ECE) as scFv-Ckappa fusion proteins and confirmed that the reactivity of the sulfhydryl group on cysteine is active and their binding activity is retained after the conjugation process. PMID:26764487

  11. Effect of Slip Time in Forming Neo-Esophageal Stenosis After Replacement of a Thoracic Esophagus With Nitinol Artificial Esophagus.

    PubMed

    Liang, Xian-Liang; Liang, Jian-Hui

    2015-07-01

    Attempts have been made to investigate the effect of slip time of nitinol artificial esophagus for forming neo-esophageal stenosis after replacement of a thoracic esophagus with nitinol artificial esophagus in 20 experimental pigs. The pigs whose slip time was less than 90 days postoperatively had severe dysphagia (Bown's III) immediately after they were fed, and the dysphagia aggravated gradually later on (Bown's III-IV). The pigs whose slip time was more than 90 days postoperatively had mild/moderate dysphagia (Bown's I-II) immediately after they were fed, and the dysphagia relieved gradually later on (Bown's II-I-0). The ratios between the diameter of neo-esophagus in different slip time and normal esophagus were 25% (at 2 months postoperatively), 58% (at 4 months postoperatively), and 93% (at 6 months postoperatively), respectively. The relationship between nitinol artificial esophagus slip time and neo-esophageal stenosis showed a positive correlation. After replacement of a thoracic esophagus with nitinol artificial esophagus, the artificial esophageal slip time not only affected the original diameter of the neo-esophagus immediately, but also affected the neo-esophageal scar stricture forming process later on. The narrowing of neo-esophagus is caused by overgrowth of scar tissue. But there is the positive correlation between artificial esophagus slip time and neo-esophageal stenosis, so this can be a way of overcoming neo-esophageal stenosis by delaying slip time of artificial esophagus. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Knee joint replacement

    MedlinePlus

    ... Knee joint replacement - series References American Academy of Orthopedic Surgeons (AAOS) website. Treatment of osteoarthritis of the knee: evidence-based guideline 2nd edition (summary) . www.aaos.org/research/guidelines/TreatmentofOsteoarthritisoftheKneeGuideline.pdf . Updated May 18, 2013. Accessed ...

  13. 77 FR 25591 - Drawbridge Operation Regulation; Intracoastal Waterway, Chesapeake, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-01

    ... replacing the lift joints of the drawbridge. This deviation restricts operation of the draw span, allowing... and to perform periodic maintenance. To facilitate replacement of the lift joints of the draw span...

  14. Getting your home ready - knee or hip surgery

    MedlinePlus

    ... Philadelphia, PA: Elsevier; 2017:chap 55. Read More ACL reconstruction Hip fracture surgery Hip joint replacement Knee ... Knee joint replacement Knee microfracture surgery Patient Instructions ACL reconstruction - discharge Hip fracture - discharge Hip or knee ...

  15. Rapid replacement of bridge deck expansion joints study - phase I : [tech transfer summary].

    DOT National Transportation Integrated Search

    2014-12-01

    This initial research phase focused on documenting the current : means and methods of bridge expansion joint deterioration, : maintenance, and replacement and on identifying improvements : through all of the input gathered.

  16. Early medication use in new-onset rheumatoid arthritis may delay joint replacement: results of a large population-based study.

    PubMed

    Moura, Cristiano S; Abrahamowicz, Michal; Beauchamp, Marie-Eve; Lacaille, Diane; Wang, Yishu; Boire, Gilles; Fortin, Paul R; Bessette, Louis; Bombardier, Claire; Widdifield, Jessica; Hanly, John G; Feldman, Debbie; Maksymowych, Walter; Peschken, Christine; Barnabe, Cheryl; Edworthy, Steve; Bernatsky, Sasha

    2015-08-03

    Use of disease-modifying anti-rheumatic drugs (DMARDs) in rheumatoid arthritis (RA) may prevent joint damage and potentially reduce joint replacement surgeries. We assessed the association between RA drug use and joint replacement in Quebec, Canada. A cohort of new-onset RA patients was identified from Quebec's physician billing and hospitalization databases from 2002-2011. The outcome was defined using procedure codes submitted by orthopedic surgeons. Medication use was obtained from pharmacy databases. We used alternative Cox regression models with time-dependent variables measuring the cumulative effects of past use during different time windows (one model focussing on the first year after cohort entry) for methotrexate (MTX), and other DMARDs. Models were adjusted for baseline sociodemographics, co-morbidity and prior health service use, time-dependent cumulative use of other drugs (anti-tumor necrosis factor [anti-TNF] agents, other biologics, cyclooxygenase-2 inhibitors [COXIBs], nonselective nonsteroidal antiinflammatory drugs [NSAIDs], and systemic steroids), and markers of disease severity. During follow-up, 608 joint replacements occurred among 11,333 patients (median follow-up: 4.6 years). The best-fitting model relied on the cumulative early use (within the first year after cohort entry) of MTX and of other DMARDs, with an interaction between MTX and other DMARDs. In this model, greater exposure within the first year, to either MTX (adjusted hazard ratio, HR = 0.95 per 1 month, 95% confidence interval, 95% CI 0.93-0.97) or other DMARDs (HR = 0.97, 95% CI 0.95-0.99) was associated with longer time to joint replacement. Our results suggest that longer exposure to either methotrexate (MTX) or other DMARDs within the first year after RA diagnosis is associated with longer time to joint replacement surgery.

  17. The research of laryngeal joints to reconstruction and modeling.

    PubMed

    Zhang, Yi; Shi, Tingchun

    2014-01-01

    Larynx has a complex structure with joints and multiple functions. In order to study the artificial larynx and artificial auricle scaffold, a three-dimensional digital model of laryngeal joint is established in this paper using MIMICS with its biomechanical properties analyzed and calculated by using the finite element method. This model is based on the CT scanned images of 281 layers with an interlamellar spacing of 1.25 mm. The obtained data are denoised, segmented and smoothed before being loaded into MIMICS. By further optimizations, an accurate and complete 3D model can be obtained. Subsequently, a 3D FEM of the normal larynx joint is performed which allows observations from any dimensions and angles. Compared with natural laryngeal joint, this model has good geometric similarity and mechanically similar throat voicing functions.

  18. Joint Center for Artificial Photosynthesis

    ScienceCinema

    Koval, Carl; Lee, Kenny; Houle, Frances; Lewis, Na

    2018-05-30

    The Joint Center for Artificial Photosynthesis (JCAP) is the nation's largest research program dedicated to the development of an artificial solar-fuel generation technology. Established in 2010 as a U.S. Department of Energy (DOE) Energy Innovation Hub, JCAP aims to find a cost-effective method to produce fuels using only sunlight, water, and carbon dioxide as inputs. JCAP brings together more than 140 top scientists and researchers from the California Institute of Technology and its lead partner, Berkeley Lab, along with collaborators from the SLAC National Accelerator Laboratory, and the University of California campuses at Irvine and San Diego.

  19. Joint Center for Artificial Photosynthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koval, Carl; Lee, Kenny; Houle, Frances

    2013-12-10

    The Joint Center for Artificial Photosynthesis (JCAP) is the nation's largest research program dedicated to the development of an artificial solar-fuel generation technology. Established in 2010 as a U.S. Department of Energy (DOE) Energy Innovation Hub, JCAP aims to find a cost-effective method to produce fuels using only sunlight, water, and carbon dioxide as inputs. JCAP brings together more than 140 top scientists and researchers from the California Institute of Technology and its lead partner, Berkeley Lab, along with collaborators from the SLAC National Accelerator Laboratory, and the University of California campuses at Irvine and San Diego.

  20. Effect of motion inputs on the wear prediction of artificial hip joints

    PubMed Central

    Liu, Feng; Fisher, John; Jin, Zhongmin

    2013-01-01

    Hip joint simulators have been largely used to assess the wear performance of joint implants. Due to the complexity of joint movement, the motion mechanism adopted in simulators varies. The motion condition is particularly important for ultra-high molecular weight polyethylene (UHMWPE) since polyethylene wear can be substantially increased by the bearing cross-shear motion. Computational wear modelling has been improved recently for the conventional UHMWPE used in total hip joint replacements. A new polyethylene wear law is an explicit function of the contact area of the bearing and the sliding distance, and the effect of multidirectional motion on wear has been quantified by a factor, cross-shear ratio. In this study, the full simulated walking cycle condition based on a walking measurement and two simplified motions, including the ISO standard motion and a simplified ProSim hip simulator motion, were considered as the inputs for wear modelling based on the improved wear model. Both the full simulation and simplified motions generated the comparable multidirectional motion required to reproduce the physiological wear of the bearing in vivo. The predicted volumetric wear of the ProSim simulator motion and the ISO motion conditions for the walking cycle were 13% and 4% lower, respectively, than that of the measured walking condition. The maximum linear wear depths were almost the same, and the areas of the wear depth distribution were 13% and 7% lower for the ProSim simulator and the ISO condition, respectively, compared with that of the measured walking cycle motion condition. PMID:25540472

  1. Current progress in inorganic artificial biomaterials.

    PubMed

    Li, Zhixia; Kawashita, Masakazu

    2011-09-01

    In this review, recent advances in bioceramics, metallic biomaterials, and their composites are discussed in terms of their material properties and new medical applications. Porous calcium phosphate ceramics have attracted a lot attention as scaffolds for tissue-engineering purposes since the porous structure allows bone ingrowth. The addition of biodegradable polymers like chitosan, gelatin, and collagen have modified the degradability of the ceramics and their mechanical properties. Titanium (Ti) alloys are being developed for the fabrication of medical devices for the replacement of hard tissue such as artificial hip joints, bone plates, and dental implants because they are very reliable from the viewpoint of mechanical performance. Physical treatment such as grooving or setting a spatial gap on the surface of materials is applicable to improve the apatite formation on the Ti alloys. Blood-compatible polymers such as poly(ethylene glycol) have been successfully fixed on the surface of Ti via chemical bonding by an electrodeposition method. New functions have been explored in Ni-free, Co-Cr-Mo alloys and Mg alloys. In addition, yttrium-containing or phosphorus-containing glass microspheres (20-30 μm in diameter) and ferrimagnetic ceramic particles have exhibited great potential to realize minimally invasive treatment of cancer without surgical operation via in situ radiotherapy or hyperthermia of cancer, but it is still a major challenge to clarify the biological reaction between the artificial implants and living body before their application.

  2. Improvement in the assessment of wear of total knee replacements using coordinate-measuring machine techniques.

    PubMed

    Blunt, L A; Bills, P J; Jiang, X-Q; Chakrabarty, G

    2008-04-01

    Total joint replacement is one of the most common elective surgical procedures performed worldwide, with an estimate of 1.5x 10(6) operations performed annually. Currently joint replacements are expected to function for 10-15 years; however, with an increase in life expectancy, and a greater call for knee replacement due to increased activity levels, there is a requirement to improve their function to offer longer-term improved quality of life for patients. Wear analysis of total joint replacements has long been an important means in determining failure mechanisms and improving longevity of these devices. The effectiveness of the coordinate-measuring machine (CMM) technique for assessing volumetric material loss during simulated life testing of a replacement knee joint has been proved previously by the present authors. The purpose of the current work is to present an improvement to this method for situations where no pre-wear data are available. To validate the method, simulator tests were run and gravimetric measurements taken throughout the test, such that the components measured had a known wear value. The implications of the results are then discussed in terms of assessment of joint functionality and development of standardized CMM-based product standards. The method was then expanded to allow assessment of clinically retrieved bearings so as to ascertain a measure of true clinical wear.

  3. [The application of electroacupuncture to postoperative rehabilitation of total knee replacement].

    PubMed

    Chen, Gang; Gu, Rui-Xin; Xu, Dan-Dan

    2012-04-01

    To explore the effect of electroacupuncture therapy for postoperative rehabilitation of total knee replacement of knee osteoarthritis. Seventy cases of total knee replacement of knee osteoarthritis were randomly divided into an acupuncture-rehabilitation group and a rehabilitation group, thirty five cases in each group. In acupuncture-rehabilitation group, routine rehabilitation therapy combined with electroacupuncture therapy was applied. The acupoints selection was mainly based on pathological location; Xuehai (SP 10), Liangqiu (ST 34), Dubi (ST 35), Neixiyan (EX-LE 4) and Yanglingquan (GB 34), etc. were selected. In rehabilitation group, routine rehabilitation therapy was applied. The functions of affected knee in both groups were evaluated by artificial total knee replacement scale of the New York Hospital for Special Surgery (HSS), range of motion (ROM) of affected knee, Visual Analogue Scale (VAS) of pain and Manual Muscle Test (MMT) before, and 2, 6 and 12 weeks after surgery. HSS scores in acupuncture-rehabilitation group were markedly higher than those in rehabilitation group in 2, 6 and 12 weeks after surgery (P < 0.05, P < 0.01); VAS scores in acupuncture-rehabilitation group were markedly lower than those in rehabilitation group (P < 0.05, P < 0.01); ROM and MMT in acupuncture-rehabilitation group were little superior to those in rehabilitation group, however, there was no significant difference (all P > 0.05). Rehabilitation therapy combined with electroacupuncture can obviously restrain the pain during rehabilitation process for total knee replacement patients, improve the endurance capacity of rehabilitation training and motivation, and obviously promote the recovery of total knee joint function.

  4. Sinus MRI scan

    MedlinePlus

    ... your body: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Recently placed artificial joints Certain types of vascular stents Pain pumps ...

  5. Experience with the use of a partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft.

    PubMed

    Birk, Stephanie; Brase, Christoph; Hornung, Joachim

    2014-08-01

    In the further development of alloplastic prostheses for use in middle ear surgery, the Dresden and Cologne University Hospitals, working together with a company, introduced a new partial ossicular replacement prosthesis in 2011. The ball-and-socket joint between the prosthesis and the shaft mimics the natural articulations between the malleus and incus and between the incus and stapes, allowing reaction to movements of the tympanic membrane graft, particularly during the healing process. Retrospective evaluation To reconstruct sound conduction as part of a type III tympanoplasty, partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft was implanted in 60 patients, with other standard partial ossicular replacement prosthesis implanted in 40 patients and 64 patients. Pure-tone audiometry was carried out, on average, 19 and 213 days after surgery. Results of the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft were compared with those of the standard prostheses. Early measurements showed a mean improvement of 3.3 dB in the air-bone gap (ABG) with the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft, giving similar results than the standard implants (6.6 and 6.0 dB, respectively), but the differences were not statistically significant. Later measurements showed a statistically significant improvement in the mean ABG, 11.5 dB, compared with 4.4 dB for one of the standard partial ossicular replacement prosthesis and a tendency of better results to 6.9 dB of the other standard prosthesis. In our patients, we achieved similarly good audiometric results to those already published for the partial ossicular replacement prosthesis with a ball-and-socket joint between the plate and the shaft. Intraoperative fixation posed no problems, and the postoperative complication rate was low.

  6. Patient and implant survival following joint replacement because of metastatic bone disease

    PubMed Central

    2013-01-01

    Background Patients suffering from a pathological fracture or painful bony lesion because of metastatic bone disease often benefit from a total joint replacement. However, these are large operations in patients who are often weak. We examined the patient survival and complication rates after total joint replacement as the treatment for bone metastasis or hematological diseases of the extremities. Patients and methods 130 patients (mean age 64 (30–85) years, 76 females) received 140 joint replacements due to skeletal metastases (n = 114) or hematological disease (n = 16) during the period 2003–2008. 21 replaced joints were located in the upper extremities and 119 in the lower extremities. Clinical and survival data were extracted from patient files and various registers. Results The probability of patient survival was 51% (95% CI: 42–59) after 6 months, 39% (CI: 31–48) after 12 months, and 29% (CI: 21–37) after 24 months. The following surgical complications were seen (8 of which led to additional surgery): 2–5 hip dislocations (n = 8), deep infection (n = 3), peroneal palsy (n = 2), a shoulder prosthesis penetrating the skin (n = 1), and disassembly of an elbow prosthesis (n = 1). The probability of avoiding all kinds of surgery related to the implanted prosthesis was 94% (CI: 89–99) after 1 year and 92% (CI: 85–98) after 2 years. Conclusion Joint replacement operations because of metastatic bone disease do not appear to have given a poorer rate of patient survival than other types of surgical treatment, and the reoperation rate was low. PMID:23530874

  7. Classification of Partial Discharge Measured under Different Levels of Noise Contamination.

    PubMed

    Jee Keen Raymond, Wong; Illias, Hazlee Azil; Abu Bakar, Ab Halim

    2017-01-01

    Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD) and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE) cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA) features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN), Adaptive Neuro-Fuzzy Inference System (ANFIS) and Support Vector Machine (SVM). It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination.

  8. An evaluation of information on the internet about a new device: the cervical artificial disc replacement.

    PubMed

    Qureshi, Sheeraz A; Koehler, Steven M; Lin, James D; Bird, Justin; Garcia, Ryan M; Hecht, Andrew C

    2012-05-01

    Cross-sectional survey. The objective of this study was to investigate the authorship, content, and quality of information available to the public on the Internet pertaining to the cervical artificial disc replacement device. The Internet is widely used by patients as an educational tool for health care information. In addition, the Internet is used as a medium for direct-to-consumer marketing. Increasing interest in cervical artificial disc replacement has led to the emergence of numerous Web sites offering information about this procedure. It is thought that patients can be influenced by information found on the Internet. A cross section of Web sites accessible to the general public was surveyed. Three commonly used search engines were used to locate 150 (50/search engine) Web sites providing information about the cervical artificial disc replacement. Each Web site was evaluated with regard to authorship and content. Fifty-three percent of the Web sites reviewed were authorized by a private physician group, 4% by an academic physician group, 13% by industry, 16% were news reports, and 14% were not otherwise categorized. Sixty-five percent of Web sites offered a mechanism for direct contact and 19% provided clear patient eligibility criteria. Benefits were expressed in 80% of Web sites, whereas associated risks were described in 35% or less. European experiences were noted in 17% of Web sites, whereas only 9% of Web sites detailed the current US experience. CONCLUSION.: The results of this study demonstrate that much of the content of the Internet-derived information pertaining to the cervical artificial disc replacement is for marketing purposes and may not represent unbiased information. Until we can confirm the content on a Web site to be accurate, patients should be cautioned when using the Internet as a source for health care information related to cervical disc replacement.

  9. Load environment of rail joint bars - phase I, effects of track parameters on rail joint stresses and crack growth.

    DOT National Transportation Integrated Search

    2013-04-01

    The load environment of joint bars was assessed under a variety of loading and track conditions. Bending stresses, thermal stresses, and residual stresses were measured on commonly used joint bars. Crack growth rates from artificially induced cracks ...

  10. 3D printing technology used in severe hip deformity.

    PubMed

    Wang, Shanshan; Wang, Li; Liu, Yan; Ren, Yongfang; Jiang, Li; Li, Yan; Zhou, Hao; Chen, Jie; Jia, Wenxiao; Li, Hui

    2017-09-01

    This study was designed to assess the use of a 3D printing technique in total hip arthroplasty (THA) for severe hip deformities, where new and improved approaches are needed. THAs were performed from January 2015 to December 2016. Bioprosthesis artificial hip joints were used in both conventional and 3D printing hip arthroplasties. A total of 74 patients (57 cases undergoing conventional hip replacements and 17 undergoing 3D printing hip replacements) were followed-up for an average of 24 months. The average age of the patients was 62.7 years. Clinical data between the patients treated with different approaches were compared. Results showed that the time to postoperative weight bearing and the Harris scores of the patients in the 3D printing group were better than those for patients in the conventional hip replacement group. Unfortunately, the postoperative infection and loosening rates were higher in the 3D printing group. However, there were no significant differences in femoral neck anteversion, neck shaft, acetabular or sharp angles between ipsilateral and contralateral sides in the 3D printing group (P>0.05). The femoral neck anteversion angle was significantly different between the two sides in the conventional hip replacement group (P<0.05). Based on these results, we suggest that the 3D printing approach provides a better short-term curative effect that is more consistent with the physiological structure and anatomical characteristics of the patient, and we anticipate that its use will help improve the lives of many patients.

  11. Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles

    NASA Astrophysics Data System (ADS)

    Chakarov, Dimitar; Veneva, Ivanka; Tsveov, Mihail; Venev, Pavel

    2018-03-01

    The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual "man-robot" interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles

  12. [Creation of artificial cartilage by nanotechnology].

    PubMed

    Murosaki, Takayuki; Gong, Jian Ping; Osada, Yoshihito

    2006-02-01

    Artificial joints are made from hard and dry materials like metal or ceramics, although these artificial joints have several problems such as bacterial infection, high surface friction and wear, lack in shock-absorption. From this viewpoint, hydrogels have a high potential as substitutes for articular cartilage, although most of them suffer from lack of mechanical strength. In our recent study, we have found hydrogels, that exhibit high fracture strength as several tens of megapascals, extremely low coefficient of friction as 10(-4), high wear resistance, and with biocompatibility. These gels might open new era of soft and wet materials as substitutes for articular cartilage and other tissues.

  13. A New Approach for Human Forearm Motion Assist by Actuated Artificial Joint-An Inner Skeleton Robot

    NASA Astrophysics Data System (ADS)

    Kundu, Subrata Kumar; Kiguchi, Kazuo; Teramoto, Kenbu

    In order to help the physical activities of the elderly or physically disabled persons, we propose a new concept of a power-assist inner skeleton robot (i.e., actuated artificial joint) that is supposed to assist the human daily life motion from inside of the human body. This paper presents an implantable 2 degree of freedom (DOF) inner skeleton robot that is designed to assist human elbow flexion-extension motion and forearm supination-pronation motion for daily life activities. We have developed a prototype of the inner skeleton robot that is supposed to assist the motion from inside of the body and act as an actuated artificial joint. The proposed system is controlled based on the activation patterns of the electromyogram (EMG) signals of the user's muscles by applying fuzzy-neuro control method. A joint actuator with angular position sensor is designed for the inner skeleton robot and a T-Mechanism is proposed to keep the bone arrangement similar to the normal human articulation after the elbow arthroplasty. The effectiveness of the proposed system has been evaluated by experiment.

  14. Partial Bibliography of Work on Expert Systems,

    DTIC Science & Technology

    1982-12-01

    Bibliography: AAAI American Association for Artificial Intelligence ACM Association for Computing Machinery AFIPS American Federation of Information...Processing Societies ECAI European Conference on Artificial Intelligence IEEE Institute for Electrical and Electronic Engineers IFIPS International...Federation of Information Processing Societies IJCAI International Joint Conferences on Artificial Intelligence SIGPLAN ACM Special Interest Group on

  15. Computer Simulated Visual and Tactile Feedback as an Aid to Manipulator and Vehicle Control,

    DTIC Science & Technology

    1981-05-08

    STATEMENT ........................ 8 Artificial Intellegence Versus Supervisory Control ....... 8 Computer Generation of Operator Feedback...operator. Artificial Intelligence Versus Supervisory Control The use of computers to aid human operators can be divided into two catagories: artificial ...operator. Artificial intelligence ( A. I. ) attempts to give the computer maximum intelligence and to replace all operator functions by the computer

  16. Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

    PubMed

    Wegmann, Kilian; Hain, Moritz K; Ries, Christian; Neiss, Wolfram F; Müller, Lars P; Burkhart, Klaus J

    2015-09-01

    The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard. The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses. Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

  17. In Defense of Artificial Replacement.

    PubMed

    Shiller, Derek

    2017-06-01

    If it is within our power to provide a significantly better world for future generations at a comparatively small cost to ourselves, we have a strong moral reason to do so. One way of providing a significantly better world may involve replacing our species with something better. It is plausible that in the not-too-distant future, we will be able to create artificially intelligent creatures with whatever physical and psychological traits we choose. Granted this assumption, it is argued that we should engineer our extinction so that our planet's resources can be devoted to making artificial creatures with better lives. © 2017 John Wiley & Sons Ltd.

  18. Sweet proteins – Potential replacement for artificial low calorie sweeteners

    PubMed Central

    Kant, Ravi

    2005-01-01

    Exponential growth in the number of patients suffering from diseases caused by the consumption of sugar has become a threat to mankind's health. Artificial low calorie sweeteners available in the market may have severe side effects. It takes time to figure out the long term side effects and by the time these are established, they are replaced by a new low calorie sweetener. Saccharine has been used for centuries to sweeten foods and beverages without calories or carbohydrate. It was also used on a large scale during the sugar shortage of the two world wars but was abandoned as soon as it was linked with development of bladder cancer. Naturally occurring sweet and taste modifying proteins are being seen as potential replacements for the currently available artificial low calorie sweeteners. Interaction aspects of sweet proteins and the human sweet taste receptor are being investigated. PMID:15703077

  19. MP Joint Arthritis

    MedlinePlus

    ... is extensive and severe, joint replacement or joint fusion are effective surgical options. Learn more about joint ... the tabs at the top (Video, Articles/WEB, Images, JHS, Products/Vendors), or the filters on the ...

  20. Does addition of low-level laser therapy (LLLT) in conservative care of knee arthritis successfully postpone the need for joint replacement?

    PubMed

    Ip, David

    2015-12-01

    The current study evaluates whether the addition of low-level laser therapy into standard conventional physical therapy in elderly with bilateral symptomatic tri-compartmental knee arthritis can successfully postpone the need for joint replacement surgery. A prospective randomized cohort study of 100 consecutive unselected elderly patients with bilateral symptomatic knee arthritis with each knee randomized to receive either treatment protocol A consisting of conventional physical therapy or protocol B which is the same as protocol A with added low-level laser therapy. The mean follow-up was 6 years. Treatment failure was defined as breakthrough pain which necessitated joint replacement surgery. After a follow-up of 6 years, patients clearly benefited from treatment with protocol B as only one knee needed joint replacement surgery, while nine patients treated with protocol A needed surgery (p < 0.05). We conclude low-level laser therapy should be incorporated into standard conservative treatment protocol for symptomatic knee arthritis.

  1. MRI

    MedlinePlus

    ... the test, tell your provider if you have: Artificial heart valves Brain aneurysm clips Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not ... artificial joints Vascular stents Worked with sheet metal in ...

  2. Magnetic resonance angiography

    MedlinePlus

    ... your provider if you have: Brain aneurysm clips Artificial heart valve Heart defibrillator or pacemaker Inner ear (cochlear) implants Insulin or chemotherapy port Intrauterine device (IUD) Kidney ... artificial joints Vascular stent Worked with sheet metal in ...

  3. Classification of Partial Discharge Measured under Different Levels of Noise Contamination

    PubMed Central

    2017-01-01

    Cable joint insulation breakdown may cause a huge loss to power companies. Therefore, it is vital to diagnose the insulation quality to detect early signs of insulation failure. It is well known that there is a correlation between Partial discharge (PD) and the insulation quality. Although many works have been done on PD pattern recognition, it is usually performed in a noise free environment. Also, works on PD pattern recognition in actual cable joint are less likely to be found in literature. Therefore, in this work, classifications of actual cable joint defect types from partial discharge data contaminated by noise were performed. Five cross-linked polyethylene (XLPE) cable joints with artificially created defects were prepared based on the defects commonly encountered on site. Three different types of input feature were extracted from the PD pattern under artificially created noisy environment. These include statistical features, fractal features and principal component analysis (PCA) features. These input features were used to train the classifiers to classify each PD defect types. Classifications were performed using three different artificial intelligence classifiers, which include Artificial Neural Networks (ANN), Adaptive Neuro-Fuzzy Inference System (ANFIS) and Support Vector Machine (SVM). It was found that the classification accuracy decreases with higher noise level but PCA features used in SVM and ANN showed the strongest tolerance against noise contamination. PMID:28085953

  4. Propulsion System with Pneumatic Artificial Muscles for Powering Ankle-Foot Orthosis

    NASA Astrophysics Data System (ADS)

    Veneva, Ivanka; Vanderborght, Bram; Lefeber, Dirk; Cherelle, Pierre

    2013-12-01

    The aim of this paper is to present the design of device for control of new propulsion system with pneumatic artificial muscles. The propulsion system can be used for ankle joint articulation, for assisting and rehabilitation in cases of injured ankle-foot complex, stroke patients or elderly with functional weakness. Proposed device for control is composed by microcontroller, generator for muscles contractions and sensor system. The microcontroller receives the control signals from sensors and modulates ankle joint flex- ion and extension during human motion. The local joint control with a PID (Proportional-Integral Derivative) position feedback directly calculates desired pressure levels and dictates the necessary contractions. The main goal is to achieve an adaptation of the system and provide the necessary joint torque using position control with feedback.

  5. Burden of Restraint, Disablement and Ethnic Identity: A Case Study of Total Joint Replacement for Osteoarthritis

    PubMed Central

    Harrison, Tracie

    2010-01-01

    Health disparities in total joint replacement have been documented based on gender and ethnicity in multiple countries. Absent are studies exploring the meaning of the procedures among diverse women, which is necessary to fully understand the impact of the disparity. Drawing on ethnographic data from a life course exploration of disablement among Mexican American women with mobility impairments, one woman’s reasons for forgoing a joint replacement are considered. It is suggested that inequalities in disablement cannot be understood without considering the mulitple cultural conflicts and loyalties that push and pull women in multiple directions. PMID:21767094

  6. Respiratory pattern changes during costovertebral joint movement.

    PubMed

    Shannon, R

    1980-05-01

    Experiments were conducted to determine if costovertebral joint manipulation (CVJM) could influence the respiratory pattern. Phrenic efferent activity (PA) was monitored in dogs that were anesthetized with Dial-urethane, vagotomized, paralyzed, and artificially ventilated. Ribs 6-10 (bilaterally) were cut and separated from ribs 5-11. Branches of thoracic nerves 5-11 were cut, leaving only the joint nerve supply intact. Manual joint movement in an inspiratory or expiratory direction had an inhibitory effect on PA. Sustained displacement of the ribs could inhibit PA for a duration equal to numerous respiratory cycles. CVJM in synchrony with PA resulted in an increased respiratory rate. The inspiratory inhibitory effect of joint receptor stimulation was elicited with manual chest compression in vagotomized spontaneously breathing dogs, but not with artificial lung inflation or deflation. It is concluded that the effect of CVJM on the respiratory pattern is due to stimulation of joint mechanoreceptors, and that they exert their influence in part via the medullary-pontine rhythm generator.

  7. MO-FG-CAMPUS-IeP3-01: Evaluation of Specific Absorption Rate and Temperature Increase Induced by Artificial Medical Implants During MRI Scan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seo, Y

    Purpose: Heating of patients or burning of biological tissues around medical implants by RF power during MRI scan is a significant patient safety concern. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation due to artificial hip joints during MRI scans. Methods: SAR measurement experiment was performed on three discrete manufacturers at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T2w inversion recovery, and T2w TSE) with imaging parameters were selected. A gelled saline phantom mimicking human body tissue was made (Fig.1). FDTD method was utilized to calculate the SAR distributionmore » using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located around two artificial hip joints inside the phantom. 56 Fiber Bragg Grating (FBG) temperature sensors (28 sensors on each artificial hip joint) were located on both left and right artificial hip joints to measure temperature change during MRI scan (Fig.1). Both E-field and FBG temperature sensors were calibrated with traceability at Korea Research Institute of Standards and Science (KRISS). Results: Simulation shows that high SAR values occur in the head and tail of the implanted artificial hip joints (Fig.1 lower right). 3T MRI scanner shows that the local averaged-SAR values measured by probe 1, 2, and 3 are 2.30, 2.77, and 1.68 W/kg, compared to MRI scanner-reported whole body SAR value (≤1.5 W/kg) for T1w TSE and T2w-IR (Table 1). The maximum temperature elevation measured by FBG sensors is 1.49°C at 1.5 T, 2.0°C at 3 T, and 2.56°C at 3 T for T1w TSE, respectively (Table 2). Conclusion: It is essential to assess the safety of MRI system for patient with medical implant by measuring not only accurate SAR deposited in the body, but also temperature elevation due to the deposited SAR during clinical MRI.« less

  8. The influence of acetabular bone cracks in the press-fit hip replacement: Numerical and experimental analysis.

    PubMed

    Ramos, A; Duarte, R J; Relvas, C; Completo, A; Simões, J A

    2013-07-01

    The press-fit hip acetabular prosthesis implantation can cause crack formation in the thin regions surrounding the acetabular. As a consequence the presence of cracks in this region can lead to poor fixation and fibrous tissue formation. Numerical and experimental models of commercial press-fit hip replacements were developed to compare the behavior between the intact and implanted joints. Numerical models with an artificial crack and without crack were considered. The iliac and the femur were created through 3D geometry acquisition based on composite human replicas and 3D-Finite Element models were generated. The mechanical behavior was assessed numerically and experimentally considering the principal strains. The comparison between Finite Element model predictions and experimental measurements revealed a maximum difference of 9%. Similar distribution of the principal strains around the acetabular cavity was obtained for the intact and implanted models. When comparing the Von Mises stresses, it is possible to observe that the intact model is the one that presents the highest stress values in the entire acetabular cavity surface. The crack in the posterior side changes significantly the principal strain distribution, suggesting bone loss after hip replacement. Relatively to micromotions, these were higher on the superior side of the acetabular cavity and can change the implant stability and bone ingrowth. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Cartilage repair and joint preservation: medical and surgical treatment options.

    PubMed

    Madry, Henning; Grün, Ulrich Wolfgang; Knutsen, Gunnar

    2011-10-01

    Articular cartilage defects are most often caused by trauma and osteoarthritis and less commonly by metabolic disorders of the subchondral bone, such as osteonecrosis and osteochondritis dissecans. Such defects do not heal spontaneously in adults and can lead to secondary osteoarthritis. Medications are indicated for symptomatic relief. Slow-acting drugs in osteoarthritis (SADOA), such as glucosamine and chondroitin, are thought to prevent cartilage degeneration. Reconstructive surgical treatment strategies aim to form a repair tissue or to unload compartments of the joint with articular cartilage damage. In this article, we selectively review the pertinent literature, focusing on original publications of the past 5 years and older standard texts. Particular attention is paid to guidelines and clinical studies with a high level of evidence, along with review articles, clinical trials, and book chapters. There have been only a few randomized trials of medical versus surgical treatments. Pharmacological therapies are now available that are intended to treat the cartilage defect per se, rather than the associated symptoms, yet none of them has yet been shown to slow or reverse the progression of cartilage destruction. Surgical débridement of cartilage does not prevent the progression of osteoarthritis and is thus not recommended as the sole treatment. Marrow-stimulating procedures and osteochondral grafts are indicated for small focal articular cartilage defects, while autologous chondrocyte implantationis mainly indicated for larger cartilage defects. These surgical reconstructive techniques play a lesser role in the treatment of osteoarthritis. Osteotomy near the knee joint is indicated for axial realignment when unilateral osteoarthritis of the knee causes axis deviation. Surgical reconstructive techniques can improve joint function and thereby postpone the need for replacement of the articular surface with an artificial joint.

  10. [Comparison of early clinical effects of two hip prosthesis designs between ceramics to ceramics and metal to polyethylene].

    PubMed

    Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng

    2013-07-01

    To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.

  11. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    PubMed

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  12. A new three-dimensional, print-on-demand temporomandibular prosthetic total joint replacement system: Preliminary outcomes.

    PubMed

    Dimitroulis, George; Austin, Stephen; Sin Lee, Peter Vee; Ackland, David

    2018-05-16

    The aim of this study is to present the preliminary clinical data on the OMX Temporomandibular Joint (TMJ) Prosthetic total joint replacement system. A prospective, cohort, clinical study was undertaken of consecutive adult patients with Category 5 end-stage joint disease who were implanted with the OMX TMJ prosthesis between May 2015 and April 2017. A total of 50 devices were implanted in 38 patients, with 12 patients receiving bilateral prosthetic joints. There were 31 females and 7 males in this cohort, who ranged in age from 20 to 66 years, with a mean of 43.8 years (±14.0 years). Ten of the 50 prosthetic joints (20%) were fully customized, while the remaining were patient matched using virtual planning software. Based on a mean follow-up period of 15.3 months (range 12-24 months) following the TMJ total joint replacement, preliminary results suggest the OMX TMJ prosthesis has made a positive impact on clinical outcomes, with a mean 74.4% reduction in joint pain levels and significant improvements (p < 0.05) in jaw function as measured by the visual analogue scales for mouth opening (30.8%), diet (77.1%), and function (59.2%). No device failures were reported during the study period. This study suggests that the print-on-demand OMX TMJ prosthesis, designed for rapid delivery of both patient-matched and fully customize devices, represents a safe, reliable and versatile implantable joint replacement system for the treatment of category 5 end-stage TMJ disease. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Patients' Perceptions of Joint Replacement Care in a Changing Healthcare System: A Qualitative Study

    PubMed Central

    Webster, Fiona; Bremner, Samantha; Katz, Joel; Watt-Watson, Judy; Kennedy, Deborah; Sawhney, Mona; McCartney, Colin

    2014-01-01

    Background: Ontario has introduced strategies over the past decade to reduce wait times and length of stay and improve access to physiotherapy for orthopaedic and other patients. The aim of this study is to explore patients' experiences of joint replacement care during a significant system change in their care setting. Methods: A secondary analysis was done on semi-structured qualitative interviews that were conducted in 2009 with 12 individuals who had undergone at least two hip or knee replacements five years apart at a specialized orthopaedic centre in Ontario, Canada. Interview transcripts were coded and then organized into themes. Results: Although the original study aimed to capture participants' experiences with changes in anaesthetic technique between their first and second joint replacements, the participants described several unrelated differences in the care they received during this period. For example, participants had difficulty obtaining a referral to an orthopaedic surgeon from their family physician. They also noted that the hospital stay and in-hospital physiotherapy they received were shorter after the second joint replacement surgery. They identified guidance from physiotherapists as an important component of their recovery, but sometimes had difficulty arranging physiotherapy after hospital discharge following their most recent surgery. Conclusions: The changes described between the first and second joint replacements provide the participants' perspective on the impact of policy changes on wait times, reduced lengths of hospital stay and physiotherapy access. The impact of these policy changes, often made in an attempt to improve access to care, had an unintended and detrimental effect on participants' perceptions and experiences of the quality of care provided. PMID:24726074

  14. Insert Modifications Improve Access to Artificial Red-Cockaded Woodpecker Next Cavities

    Treesearch

    John W. Edwards; Ernest E. Stevens; Charles A. Dachelet

    1997-01-01

    A designfor a modified, artificial Red-cockaded Woodpecker(Picoides borealis) cavity insert is presented. This modification allowed eggs and young to be inspected easily, removed, and replaced throughout the nesting period. Modifications to cavity inserts are best done before installation, but can be easily retrofitted in existing artificial cavities...

  15. Pre-operative interventions (non-surgical and non-pharmacological) for patients with hip or knee osteoarthritis awaiting joint replacement surgery--a systematic review and meta-analysis.

    PubMed

    Wallis, Jason A; Taylor, Nicholas F

    2011-12-01

    To determine if pre-operative interventions for hip and knee osteoarthritis provide benefit before and after joint replacement. Systematic review with meta-analysis of randomised controlled trials (RCTs) of pre-operative interventions for people with hip or knee osteoarthritis awaiting joint replacement surgery. Standardised mean differences (SMD) were calculated for pain, musculoskeletal impairment, activity limitation, quality of life, and health service utilisation (length of stay and discharge destination). The GRADE approach was used to determine the quality of the evidence. Twenty-three RCTs involving 1461 participants awaiting hip or knee replacement surgery were identified. Meta-analysis provided moderate quality evidence that pre-operative exercise interventions for knee osteoarthritis reduced pain prior to knee replacement surgery (SMD (95% CI)=0.43 [0.13, 0.73]). None of the other meta-analyses investigating pre-operative interventions for knee osteoarthritis demonstrated any effect. Meta-analyses provided low to moderate quality evidence that exercise interventions for hip osteoarthritis reduced pain (SMD (95% CI)=0.52 [0.04, 1.01]) and improved activity (SMD (95% CI)=0.47 [0.11, 0.83]) prior to hip replacement surgery. Meta-analyses provided low quality evidence that exercise with education programs improved activity after hip replacement with reduced time to reach functional milestones during hospital stay (e.g., SMD (95% CI)=0.50 [0.10, 0.90] for first day walking). Low to moderate evidence from mostly small RCTs demonstrated that pre-operative interventions, particularly exercise, reduce pain for patients with hip and knee osteoarthritis prior to joint replacement, and exercise with education programs may improve activity after hip replacement. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  16. Artificial tears potpourri: a literature review

    PubMed Central

    Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F

    2014-01-01

    Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. PMID:25114502

  17. The activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain

    PubMed Central

    Yue, James J; Garcia, Rolando; Miller, Larry E

    2016-01-01

    Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration − the Charité Artificial Disc in 2004 and the ProDisc-L Total Disc Replacement in 2006. In June 2015, a next-generation lumbar TDR received Food and Drug Administration approval − the activL® Artificial Disc (Aesculap Implant Systems). Compared to previous-generation lumbar TDRs, the activL® Artificial Disc incorporates specific design enhancements that result in a more precise anatomical match and allow a range of motion that better mimics the healthy spine. The results of mechanical and clinical studies demonstrate that the activL® Artificial Disc results in improved mechanical and clinical outcomes versus earlier-generation artificial discs and compares favorably to lumbar fusion. The purpose of this report is to describe the activL® Artificial Disc including implant characteristics, intended use, surgical technique, postoperative care, mechanical testing, and clinical experience to date. PMID:27274317

  18. [Minimally invasive approaches to hip and knee joints for total joint replacement].

    PubMed

    Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F

    2004-11-01

    The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.

  19. Poly(ethylene glycol)/chitosan/sodium glycerophosphate gel replaced the joint capsule with slow-release lubricant after joint surgery.

    PubMed

    Lu, Hailin; Ren, Shanshan; Li, Xing; Guo, Junde; Dong, Guangneng; Li, Jianhui; Gao, Li

    2018-08-01

    Body fluid is normally the only lubricant after joint replacement surgery, but wear problems have occurred because body fluid has poor lubrication ability. However, traditional lubricant would be diluted by body fluids and then absorbed by the human body. Therefore, an injectable gel with the ability to slow-release lubricant was designed to replace the joint capsule. The proposed gel, poly(ethylene glycol)/chitosan/sodium glycerophosphate (PEG/CS/GP) composite gel was then tested. The tribology results showed that the PEG/CS/GP gel had excellent slow-release properties, especially under pressure, and the PEG played an important role in improving the gel's rheological and mechanical properties. Moreover, this study revealed that the release solution had a good lubrication effect because the PEG and GP could crosslink via the hydrogen bond effect.

  20. Functional tooth restoration by next-generation bio-hybrid implant as a bio-hybrid artificial organ replacement therapy

    PubMed Central

    Oshima, Masamitsu; Inoue, Kaoru; Nakajima, Kei; Tachikawa, Tetsuhiko; Yamazaki, Hiromichi; Isobe, Tomohide; Sugawara, Ayaka; Ogawa, Miho; Tanaka, Chie; Saito, Masahiro; Kasugai, Shohei; Takano-Yamamoto, Teruko; Inoue, Takashi; Tezuka, Katsunari; Kuboki, Takuo; Yamaguchi, Akira; Tsuji, Takashi

    2014-01-01

    Bio-hybrid artificial organs are an attractive concept to restore organ function through precise biological cooperation with surrounding tissues in vivo. However, in bio-hybrid artificial organs, an artificial organ with fibrous connective tissues, including muscles, tendons and ligaments, has not been developed. Here, we have enveloped with embryonic dental follicle tissue around a HA-coated dental implant, and transplanted into the lower first molar region of a murine tooth-loss model. We successfully developed a novel fibrous connected tooth implant using a HA-coated dental implant and dental follicle stem cells as a bio-hybrid organ. This bio-hybrid implant restored physiological functions, including bone remodelling, regeneration of severe bone-defect and responsiveness to noxious stimuli, through regeneration with periodontal tissues, such as periodontal ligament and cementum. Thus, this study represents the potential for a next-generation bio-hybrid implant for tooth loss as a future bio-hybrid artificial organ replacement therapy. PMID:25116435

  1. Influences of post weld heat treatment on tensile strength and microstructure characteristics of friction stir welded butt joints of AA2014-T6 aluminum alloy

    NASA Astrophysics Data System (ADS)

    Rajendran, C.; Srinivasan, K.; Balasubramanian, V.; Balaji, H.; Selvaraj, P.

    2016-08-01

    Friction stir welded (FSWed) joints of aluminum alloys exhibited a hardness drop in both the advancing side (AS) and retreating side (RS) of the thermo-mechanically affected zone (TMAZ) due to the thermal cycle involved in the FSW process. In this investigation, an attempt has been made to overcome this problem by post weld heat treatment (PWHT) methods. FSW butt (FSWB) joints of Al-Cu (AA2014-T6) alloy were PWHT by two methods such as simple artificial aging (AA) and solution treatment followed by artificial aging (STA). Of these two treatments, STA was found to be more beneficial than the simple aging treatment to improve the tensile properties of the FSW joints of AA2014 aluminum alloy.

  2. Modeling and Evaluating Emotions Impact on Cognition

    DTIC Science & Technology

    2013-07-01

    Causality and Responsibility Judgment in Multi-Agent Interactions: Extended abstract. 23rd International Joint Conference on Artificial Inteligence ...responsibility judgment in multi-agent interactions." Journal of Artificial Intelligence Research v44(1), 223- 273. • Morteza Dehghani, Jonathan Gratch... Artificial Intelligence (AAAI’11). Grant related invited talks: • Keynote speaker, Workshop on Empathic and Emotional Agents at the International

  3. Autonomous Inter-Task Transfer in Reinforcement Learning Domains

    DTIC Science & Technology

    2008-08-01

    Twentieth International Joint Conference on Artificial Intelli - gence, 2007. 304 Fumihide Tanaka and Masayuki Yamamura. Multitask reinforcement learning...Functions . . . . . . . . . . . . . . . . . . . . . . 17 2.2.3 Artificial Neural Networks . . . . . . . . . . . . . . . . . . . . 18 2.2.4 Instance-based...tures [Laird et al., 1986, Choi et al., 2007]. However, TL for RL tasks has only recently been gaining attention in the artificial intelligence

  4. Smart Collections: Can Artificial Intelligence Tools and Techniques Assist with Discovering, Evaluating and Tagging Digital Learning Resources?

    ERIC Educational Resources Information Center

    Leibbrandt, Richard; Yang, Dongqiang; Pfitzner, Darius; Powers, David; Mitchell, Pru; Hayman, Sarah; Eddy, Helen

    2010-01-01

    This paper reports on a joint proof of concept project undertaken by researchers from the Flinders University Artificial Intelligence Laboratory in partnership with information managers from the Education Network Australia (edna) team at Education Services Australia to address the question of whether artificial intelligence techniques could be…

  5. Cervical MRI scan

    MedlinePlus

    ... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...

  6. Lumbar MRI scan

    MedlinePlus

    ... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...

  7. Shoulder MRI scan

    MedlinePlus

    ... you have: Brain aneurysm clips Certain types of artificial heart valves Heart defibrillator or pacemaker Inner ear (cochlear) implants Kidney disease or dialysis (you may not be able to receive contrast) Recently placed artificial joints Certain types of vascular stents Worked with ...

  8. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242)

    PubMed Central

    Dülger, L. Canan; Kapucu, Sadettin

    2016-01-01

    This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot's joint angles. PMID:27610129

  9. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242).

    PubMed

    Almusawi, Ahmed R J; Dülger, L Canan; Kapucu, Sadettin

    2016-01-01

    This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot's joint angles.

  10. An activated energy approach for accelerated testing of the deformation of UHMWPE in artificial joints.

    PubMed

    Galetz, Mathias Christian; Glatzel, Uwe

    2010-05-01

    The deformation behavior of ultrahigh molecular polyethylene (UHMWPE) is studied in the temperature range of 23-80 degrees C. Samples are examined in quasi-static compression, tensile and creep tests to determine the accelerated deformation of UHMWPE at elevated temperatures. The deformation mechanisms under compression load can be described by one strain rate and temperature dependent Eyring process. The activation energy and volume of that process do not change between 23 degrees C and 50 degrees C. This suggests that the deformation mechanism under compression remains stable within this temperature range. Tribological tests are conducted to transfer this activated energy approach to the deformation behavior under loading typical for artificial knee joints. While this approach does not cover the wear mechanisms close to the surface, testing at higher temperatures is shown to have a significant potential to reduce the testing time for lifetime predictions in terms of the macroscopic creep and deformation behavior of artificial joints. Copyright 2010. Published by Elsevier Ltd.

  11. Vibration arthrometry in the patients with failed total knee replacement.

    PubMed

    Jiang, C C; Lee, J H; Yuan, T T

    2000-02-01

    This is a preliminary research on the vibration arthrometry of artificial knee joint in vivo. Analyzing the vibration signals measured from the accelerometer on patella, there are two speed protocols in knee kinematics: 1) 2 degrees/s, the signal is called "physiological patellofemoral crepitus (PPC)", and 2) 67 degrees/s, the signal is called "vibration signal in rapid knee motion". The study has collected 14 patients who had revision total knee arthroplasty due to prosthetic wear or malalignment represent the failed total knee replacement (FTKR), and 12 patients who had just undergone the primary total knee arthroplasty in the past two to six months and have currently no knee pain represent the normal total knee replacement (NTKR). FTKR is clinically divided into three categories: metal wear, polyethylene wear of the patellar component, and no wear but with prosthesis malalignment. In PPC, the value of root mean square (rms) is used as a parameter; in vibration signals in rapid knee motion, autoregressive modeling is used for adaptive segmentation and extracting the dominant pole of each signal segment to calculate the spectral power ratios in f < 100 Hz and f > 500 Hz. It was found that in the case of metal wear, the rms value of PPC signal is far greater than a knee joint with polyethylene wear and without wear, i.e., PPC signal appears only in metal wear. As for vibration signals in rapid knee motion, prominent time-domain vibration signals could be found in the FTKR patients with either polyethylene or metal wear of the patellar component. We also found that for normal knee joint, the spectral power ratio of dominant poles has nearly 80% distribution in f < 100 Hz, is between 50% and 70% for knee with polyethylene wear and below 30% for metal wear, whereas in f > 500 Hz, spectral power ratio of dominant poles has over 30% distribution in metal wear but only nonsignificant distribution in polyethylene wear, no wear, and normal knee. The results show that vibration signals in rapid knee motion can be used for effectively detecting polyethylene wear of the patellar component in the early stage, while PPC signals can only be used to detect prosthetic metal wear in the late stage.

  12. [A cyborg is only human].

    PubMed

    Schermer, Maartje H N

    2013-01-01

    New biomedical technologies make it possible to replace parts of the human body or to substitute its functions. Examples include artificial joints, eye lenses and arterial stents. Newer technologies use electronics and software, for example in brain-computer interfaces such as retinal implants and the exoskeleton MindWalker. Gradually we are creating cyborgs: hybrids of man and machine. This raises the question: are cyborgs still humans? It is argued that they are. First, because employing technology is a typically human characteristic. Second, because in western thought the human mind, and not the body, is considered to be the seat of personhood. However, it has been argued by phenomenological philosophers that the body is more than just an object but is also a subject, important for human identity. From this perspective, we can appreciate that a bionic body does not make one less human, but it does influence the experience of being human.

  13. Study on the friction of κ-carrageenan hydrogels in air and aqueous environments.

    PubMed

    Kozbial, Andrew; Li, Lei

    2014-03-01

    Understanding the friction mechanism of polysaccharide hydrogels, which is the key component of human cartilage that has very low friction coefficient, is critical to develop next generation artificial joint replacement materials. In this study, the friction of the polysaccharide κ-carrageenan hydrogel was investigated to elucidate the effect of external load, cross-linking density, velocity, and environment on friction. Our experimental results show that (1) coefficient of friction (COF) decreases with normal load in air and remains constant in water, (2) increasing cross-linking density concurrently increases friction and is proportional to Young's modulus, (3) COF increases with testing velocity in both air and water, and (4) friction is reduced in aqueous environment due to the lubricating effect of water. The underlying frictional mechanism is discussed on the basis of water transport from bulk to surface and a previously proposed "repulsion-adsorption" model. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Regional analgesia for improvement of long-term functional outcome after elective large joint replacement.

    PubMed

    Atchabahian, Arthur; Schwartz, Gary; Hall, Charles B; Lajam, Claudette M; Andreae, Michael H

    2015-08-13

    Regional analgesia is more effective than conventional analgesia for controlling pain and may facilitate rehabilitation after large joint replacement in the short term. It remains unclear if regional anaesthesia improves functional outcomes after joint replacement beyond three months after surgery. To assess the effects of regional anaesthesia and analgesia on long-term functional outcomes 3, 6 and 12 months after elective major joint (knee, shoulder and hip) replacement surgery. We performed an electronic search of several databases (CENTRAL, MEDLINE, EMBASE, CINAHL), and handsearched reference lists and conference abstracts. We updated our search in June 2015. We included randomized controlled trials (RCTs) comparing regional analgesia versus conventional analgesia in patients undergoing total shoulder, hip or knee replacement. We included studies that reported a functional outcome with a follow-up of at least three months after surgery. We used standard methodological procedures expected by Cochrane. We contacted study authors for additional information. We included six studies with 350 participants followed for at least three months. All of these studies enrolled participants undergoing total knee replacement. Studies were at least partially blinded. Three studies had a high risk of performance bias and one a high risk of attrition bias, but the risk of bias was otherwise unclear or low.Only one study assessed joint function using a global score. Due to heterogeneity in outcome and reporting, we could only pool three out of six RCTs, with range of motion assessed at three months after surgery used as a surrogate for joint function. All studies had a high risk of detection bias. Using the random-effects model, there was no statistically significant difference between the experimental and control groups (mean difference 3.99 degrees, 95% confidence interval (CI) - 2.23 to 10.21; P value = 0.21, 3 studies, 140 participants, very low quality evidence).We did not perform further analyses because immediate adverse effects were not part of the explicit outcomes of any of these typically small studies, and long-term adverse events after regional anaesthesia are rare.None of the included studies elicited or reported long-term adverse effects like persistent nerve damage. More high-quality studies are needed to establish the effects of regional analgesia on function after major joint replacement, as well as on the risk of adverse events (falls).

  15. Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis

    PubMed Central

    Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil

    2012-01-01

    Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869

  16. Total hip arthroplasty in dwarfism. A case report.

    PubMed

    De Fine, Marcello; Traina, Francesco; Palmonari, Massimo; Tassinari, Enrico; Toni, Aldo

    2008-05-01

    In dwarfism hip arthritis, usually secondary to hip dysplasia, is a common finding at an early age. In these patients a joint replacement is a demanding procedure due to the peculiar joint deformity and the small size of the bones. We present a case of a bilateral hip replacement in a dwarf patient. In order to reduce intraoperative complications and improve the joint kinematics a thorough preoperative planning was performed by a CT based computerised system. On the basis of the planning we chose a conical shaped stem that enable as to restore limb length and offset with a low risk of femoral fracture. In conclusion, we consider total hip replacement in dwarfism a safe and effective procedure if an accurate preoperative planning is performed.

  17. Healthcare Utilization and Costs of Knee or Hip Replacements versus Pain-Relief Injections

    PubMed Central

    Pasquale, Margaret K.; Louder, Anthony M.; Cheung, Raymond Y.; Reiners, Andrew T.; Mardekian, Jack; Sanchez, Robert J.; Goli, Veerainder

    2015-01-01

    Background Given the dramatic increase in total knee and hip replacement procedures among the US population aged 45 years and older, there is a need to compare the downstream healthcare utilization and costs between patients who undergo joint replacement and those who receive intraarticular injections as a low-cost alternative. Objective To compare changes in osteoarthritis (OA)-related healthcare utilization and costs for Medicare members with OA who underwent knee or hip replacement versus those receiving steroid or viscosupplementation injections. Methods Medicare members aged ≥45 years diagnosed with OA were identified for this retrospective longitudinal study. Data were compared for patients who underwent primary knee or hip replacement surgery between July 1, 2007, and June 30, 2012, and those receiving injection of pain-relief medication during the same period. The date of joint replacement surgery was considered the index date. For the comparison cohort, the index date was 180 days postinjection of the first intraarticular injection. Medical and pharmacy claims were examined longitudinally in 90-day increments, from 180 days preindex until 360 days postindex. Difference-in-difference analyses were conducted to compare the change in OA-related healthcare costs, postindex versus preindex, between the study cohorts. Time-to-event analyses were used to measure rates of readmissions and venous thromboembolism (VTE). Results The mean age was 70.7 years for patients with knee replacement, 71.7 years for those with hip replacement, and 71.1 years for those receiving pain-relief injection (P <.0001). The RxRisk-V comorbidity index scores were 4.7, 4.4, and 4.8, respectively (P <.0001). Difference-in-difference analyses indicated that decreases in OA-related costs were greater for the joint replacement cohorts (coefficient for knee replacement*time: −0.603; hip replacement*time: −0.438; P <.001 for both) than for the comparison cohort. The VTE rates were 5.6% (knee) and 5.1% (hip) postsurgery versus 1.4% (knee) and 1.3% (hip) presurgery. Conclusion The overall difference-in-difference results showed a greater decrease in healthcare utilization and costs for the members with joint replacement than for those receiving injection. PMID:26557232

  18. Evaluation of Silicone as an Artificial Lubricant in Osteoarthrotic Joints

    PubMed Central

    Wright, V.; Haslock, D. I.; Dowson, D.; Seller, P. C.; Reeves, B.

    1971-01-01

    Silicone 300 has been evaluated as an artificial lubricant in osteoarthrotic joints by means of a pilot study in five inpatients and a control trial of 25 outpatients with 40 osteoarthrotic knees. Sequential analysis showed a significant benefit from saline compared with silicone at one week follow-up and no significant difference at one month. Measurement of stiffness with a knee arthrograph showed no difference in reduction of stiffness between the two substances. In a study of 18 rabbits there was no evidence that silicone was retained in the joint cavity for longer than 48 hours. There was a failure of clearance of iodinated serum albumin for as long as three to four days after the injection of silicone, suggesting some obstruction to lymphatic outflow. Experimentally produced cartilaginous defects did not heal quicker with the injection of silicone into the joint. PMID:5575973

  19. Hip contact forces in asymptomatic total hip replacement patients differ from normal healthy individuals: Implications for preclinical testing.

    PubMed

    Li, Junyan; Redmond, Anthony C; Jin, Zhongmin; Fisher, John; Stone, Martin H; Stewart, Todd D

    2014-08-01

    Preclinical durability testing of hip replacement implants is standardised by ISO-14242-1 (2002) which is based on historical inverse dynamics analysis using data obtained from a small sample of normal healthy individuals. It has not been established whether loading cycles derived from normal healthy individuals are representative of loading cycles occurring in patients following total hip replacement. Hip joint kinematics and hip contact forces derived from multibody modelling of forces during normal walking were obtained for 15 asymptomatic total hip replacement patients and compared to 38 normal healthy individuals and to the ISO standard for pre-clinical testing. Hip kinematics in the total hip replacement patients were comparable to the ISO data and the hip contact force in the normal healthy group was also comparable to the ISO cycles. Hip contact forces derived from the asymptomatic total hip replacement patients were comparable for the first part of the stance period but exhibited 30% lower peak loads at toe-off. Although the ISO standard provides a representative kinematic cycle, the findings call into question whether the hip joint contact forces in the ISO standard are representative of those occurring in the joint following total hip replacement. Copyright © 2014. Published by Elsevier Ltd.

  20. Joint awareness after total knee arthroplasty is affected by pain and quadriceps strength.

    PubMed

    Hiyama, Y; Wada, O; Nakakita, S; Mizuno, K

    2016-06-01

    There is a growing interest in the use of patient-reported outcomes to provide a more patient-centered view on treatment. Forgetting the artificial joint can be regarded as the goal in joint arthroplasty. The goals of the study were to describe changes in joint awareness in the artificial joint after total knee arthroplasty (TKA), and to determine which factors among pain, knee range of motion (ROM), quadriceps strength, and functional ability affect joint awareness after TKA. Patients undergoing TKA demonstrate changes in joint awareness and joint awareness is associated with pain, knee ROM, quadriceps strength, and functional ability. This prospective cohort study comprised 63 individuals undergoing TKA, evaluated at 1, 6, and 12 months postoperatively. Outcomes included joint awareness assessed using the Forgotten Joint Score (FJS), pain score, knee ROM, quadriceps strength, and functional ability. Fifty-eight individuals completed all postoperative assessments. All measures except for knee extension ROM improved from 1 to 6 months. However, there were no differences in any measures from 6 to 12 months. FJS was affected most greatly by pain at 1 month and by quadriceps strength at 6 and 12 months. Patients following TKA demonstrate improvements in joint awareness and function within 6 months after surgery, but reach a plateau from 6 to 12 months. Quadriceps strength could contribute to this plateau of joint awareness. Prospective cohort study, IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    PubMed

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Pessimistic Determination of Mechanical Conditions and Micro/macroeconomic Evaluation of Mine Pillar Replacement

    NASA Astrophysics Data System (ADS)

    Chen, Qingfa; Zhao, Fuyu

    2017-12-01

    Numerous pillars are left after mining of underground mineral resources using the open stope method or after the first step of the partial filling method. The mineral recovery rate can, however, be improved by replacement recovery of pillars. In the present study, the relationships among the pillar type, minimum pillar width, and micro/macroeconomic factors were investigated from two perspectives, namely mechanical stability and micro/macroeconomic benefit. Based on the mechanical stability formulas for ore and artificial pillars, the minimum width for a specific pillar type was determined using a pessimistic criterion. The microeconomic benefit c of setting an ore pillar, the microeconomic benefit w of artificial pillar replacement, and the economic net present value (ENPV) of the replacement process were calculated. The values of c and w were compared with respect to ENPV, based on which the appropriate pillar type and economical benefit were determined.

  3. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  4. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  5. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  6. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  7. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  8. Information Processing Research.

    DTIC Science & Technology

    1986-09-01

    Kuroe. The 3D MOSAIC Scene Understanding System. In Alan Bundy, Editor, Proceedings of the Eighth International Joint Conference on Artificial ... Artificial Jntelligencel7(1-3):409-460, August, 1981. Given a single picture which is a projection of a three-dimensional scene onto the two...values are detected as outliers by computing the distribution of values over a sliding 80 msec window. During the third pass (based on artificial

  9. Model-Based Reasoning in the Detection of Satellite Anomalies

    DTIC Science & Technology

    1990-12-01

    Conference on Artificial Intellegence . 1363-1368. Detroit, Michigan, August 89. Chu, Wei-Hai. "Generic Expert System Shell for Diagnostic Reasoning... Intellegence . 1324-1330. Detroit, Michigan, August 89. de Kleer, Johan and Brian C. Williams. "Diagnosing Multiple Faults," Artificial Intellegence , 32(1): 97...Benjamin Kuipers. "Model-Based Monitoring of Dynamic Systems," Proceedings of the Eleventh Intematianal Joint Conference on Artificial Intellegence . 1238

  10. [Evaluation of Artificial Hip Joint with Radiofrequency Heating Issues during MRI Examination: A Comparison between 1.5 T and 3 T].

    PubMed

    Yamazaki, Masaru; Ideta, Takahiro; Kudo, Sadahiro; Nakazawa, Masami

    2016-06-01

    In magnetic resonance imaging (MRI), when radiofrequency (RF) is irradiated to a subject with metallic implant, it can generate heat by RF irradiation. Recently 3 T MRI scanner has spread widely and imaging for any regions of whole body has been conducted. However specific absorption rate (SAR) of 3 T MRI becomes approximately four times as much as the 1.5 T, which can significantly affect the heat generation of metallic implants. So, we evaluated RF heating of artificial hip joints in different shapes and materials in 1.5 T and 3 T MRI. Three types of artificial hip joints made of stainless alloy, titanium alloy and cobalt chrome alloy were embedded in the human body-equivalent phantom respectively and their temperature change were measured for twenty minutes by 1.5 T and 3 T MRI. The maximum temperature rise was observed at the bottom head in all of three types of artificial hip joints, the rise being 12°C for stainless alloy, 11.9°C for titanium alloy and 6.1°C for cobalt chrome alloy in 1.5 T. The temperature rise depended on SAR and the increase of SAR had a good linear relationship with the temperature rise. It was found from the result that the RF heating of metallic implants can take place in various kinds of material and the increase of SAR has a good linear relationship with the temperature rise. This experience shows that reduction of SAR can decrease temperature of metallic implants.

  11. [Efficacy analysis on hip replacement for hip-joint diseases with Parkinson disease].

    PubMed

    Sun, Qi-Cai; Ru, Xuan-Liang; Xia, Yan-Fei; Liu, Xiao-Li; Song, Bai-Shan; Qiao, Song; Yan, Shi-Gui; Wang, Xiang-Hua

    2017-12-25

    To explore clinical efficacy of hip replacement for hip-joint diseases with Parkinson disease. From December 2011 to December 2016, 18 patients with hip-joint diseases with Parkinson disease treated by hip replacement, including 8 males and 10 females aged from 59 to 87 years old with an average of 71 years old. Among them, 3 cases were developmental dysplasia of hip, 3 cases were femoral head necrosis and 12 cases were femoral neck fracture. All patients manifested with obvious pain and limitation of stepping ability. Postoperative complications were observed and Harris score were used to compare hip joint function after operation. The incision were healed well, and pain were alleviated or disappeared, and hip joint function were improved. Eighteen patients were followed up from 1 to 3 years with an average of 2.3 years. At the latest follow up, 14 cases recovered freedom-walk, 2 cases could walk with walking stick, 1 case could walk with walking aid and 1 case was died. Among 18 patients, 2 cases were occurred dislocation, and 1 case were died for cardiac disease at 3 months after operation. Four patients were occurred slight pain. There were significant differences in Harris scores among preoperative (41.7±1.4), 6 months after operation(80.1±5.4) and the final follow-up (83.4±2.1), and 10 cases got excellent result, 4 good, 1 fair and 2 poor. Application of hip replacement for hip-joint diseases with Parkinson disease is a safe and effective clinical therapy, and has advantages of less complications and rapid recovery of hip joint function.

  12. Artificial organs 2011: a year in review.

    PubMed

    Malchesky, Paul S

    2012-03-01

    In this Editor's Review, articles published in 2011 are organized by category and briefly summarized. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, and the International Society for Rotary Blood Pumps, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level."Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ replacement, recovery, and regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers, the quality expected from such a journal would not be possible. We also express our special thanks to our Publisher, Wiley-Blackwell, for their expert attention and support in the production and marketing of Artificial Organs. In this Editor's Review, that historically has been widely well-received by our readership, we aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ replacement, recovery, and regeneration. We look forward to recording further advances in the coming years. © 2012, Copyright the Author. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. Artificial Organs 2012: a year in review.

    PubMed

    Malchesky, Paul S

    2013-03-01

    In this editor's review, articles published in 2012 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ replacement, recovery, and regeneration. As the official journal of the International Federation for Artificial Organs, the International Faculty for Artificial Organs, and the International Society for Rotary Blood Pumps, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ replacement, recovery, and regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide such meaningful suggestions to the author's work whether eventually accepted or rejected, and especially to those whose native tongue is not English. Without these excellent and dedicated reviewers, the quality expected from such a journal could not be possible. We also express our special thanks to our publisher, Wiley Periodicals, for their expert attention and support in the production and marketing of Artificial Organs. We look forward to recording further advances in the coming years. © 2013, Copyright the Author. Artificial Organs © 2013, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Cervical facet force analysis after disc replacement versus fusion.

    PubMed

    Patel, Vikas V; Wuthrich, Zachary R; McGilvray, Kirk C; Lafleur, Matthew C; Lindley, Emily M; Sun, Derrick; Puttlitz, Christian M

    2017-05-01

    Cervical total disc replacement was developed to preserve motion and reduce adjacent-level degeneration relative to fusion, yet concerns remain that total disc replacement will lead to altered facet joint loading and long-term facet joint arthrosis. This study is intended to evaluate changes in facet contact force, pressure and surface area at the treated and superior adjacent levels before and after discectomy, disc replacement, and fusion. Ten fresh-frozen human cadaveric cervical spines were potted from C2 to C7 with pressure sensors placed into the facet joints of C3-C4 and C4-C5 via slits in the facet capsules. Moments were applied to the specimens to produce axial rotation, lateral bending and extension. Facet contact force and pressure were measured at both levels for intact, discectomy at C4-C5, disc replacement with ProDisc-C (Synthes Spine, West Chester, Pennsylvania, USA) at C4-C5, and anterior discectomy and fusion with Cervical Spine Locking Plate (Synthes Spine, West Chester, Pennsylvania, USA) at C4-C5. Facet contact area was calculated from the force and pressure measurements. An analysis of variance was used to determine significant differences with P-values <0.05 indicating significance. Facet contact force was elevated at the treated level under extension following both discectomy and disc replacement, while facet contact pressure and area were relatively unchanged. Facet contact force and area were decreased at the treated level following fusion for all three loading conditions. Total disc replacement preserved facet contact force for all scenarios except extension at the treated level, highlighting the importance of the anterior disco-ligamentous complex. This could promote treated-level facet joint disease. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... replaced. (d) Each rail shall be bolted with at least two bolts at each joint. (e) Each joint bar shall be... in this subpart. (f) No rail shall have a bolt hole which is torch cut or burned. (g) No joint bar shall be reconfigured by torch cutting. ...

  16. Load Transmission Through Artificial Hip Joints due to Stress Wave Loading

    NASA Astrophysics Data System (ADS)

    Tanabe, Y.; Uchiyama, T.; Yamaoka, H.; Ohashi, H.

    Since wear of the polyethylene (Ultra High Molecular Weight Polyethylene or UHMWPE) acetabular cup is considered to be the main cause of loosening of the artificial hip joint, the cross-linked UHMWPE with high durability to wear has been developed. This paper deals with impact load transmission through the complex of an artificial hip joint consisting of a UHMWPE acetabular cup (or liner), a metallic femoral head and stem. Impact compressive tests on the complex were performed using the split-Hopkinson pressure bar apparatus. To investigate the effects of material (conventional or cross-linked UHMWPE), size and setting angle of the liner, and test temperature on force transmission, the impact load transmission ratio (ILTR) was experimentally determined. The ILTR decreased with an increase of the setting angle independent of material and size of the liner, and test temperature. The ILTR values at 37°C were larger than those at 24 °C and 60°C. The ILTR also appeared to be affected by the type of material as well as size of the liner.

  17. Recycling ground granulated blast furnace slag as cold bonded artificial aggregate partially used in self-compacting concrete.

    PubMed

    Gesoğlu, Mehmet; Güneyisi, Erhan; Mahmood, Swara Fuad; Öz, Hatice Öznur; Mermerdaş, Kasım

    2012-10-15

    Ground granulated blast furnace slag (GGBFS), a by-product from iron industry, was recycled as artificial coarse aggregate through cold bonding pelletization process. The artificial slag aggregates (ASA) replaced partially the natural coarse aggregates in production of self-compacting concrete (SCC). Moreover, as being one of the most widely used mineral admixtures in concrete industry, fly ash (FA) was incorporated as a part of total binder content to impart desired fluidity to SCCs. A total of six concrete mixtures having various ASA replacement levels (0%, 20%, 40%, 60%, and 100%) were designed with a water-to-binder (w/b) ratio of 0.32. Fresh properties of self-compacting concretes (SCC) were observed through slump flow time, flow diameter, V-funnel flow time, and L-box filling height ratio. Compressive strength of hardened SCCs was also determined at 28 days of curing. It was observed that increasing the replacement level of ASA resulted in decrease in the amount of superplasticizer to achieve a constant slump flow diameter. Moreover, passing ability and viscosity of SCC's enhanced with increasing the amount of ASA in the concrete. The maximum compressive strength was achieved for the SCC having 60% ASA replacement. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Regional analgesia for improvement of long-term functional outcome after elective large joint replacement

    PubMed Central

    Atchabahian, Arthur; Schwartz, Gary; Hall, Charles B; Lajam, Claudette M; Andreae, Michael H

    2015-01-01

    Background Regional analgesia is more effective than conventional analgesia for controlling pain and may facilitate rehabilitation after large joint replacement in the short term. It remains unclear if regional anaesthesia improves functional outcomes after joint replacement beyond three months after surgery. Objectives To assess the effects of regional anaesthesia and analgesia on long-term functional outcomes 3, 6 and 12 months after elective major joint (knee, shoulder and hip) replacement surgery. Search methods We performed an electronic search of several databases (CENTRAL, MEDLINE, EMBASE, CINAHL), and handsearched reference lists and conference abstracts. We updated our search in June 2015. Selection criteria We included randomized controlled trials (RCTs) comparing regional analgesia versus conventional analgesia in patients undergoing total shoulder, hip or knee replacement. We included studies that reported a functional outcome with a follow-up of at least three months after surgery. Data collection and analysis We used standard methodological procedures expected by Cochrane. We contacted study authors for additional information. Main results We included six studies with 350 participants followed for at least three months. All of these studies enrolled participants undergoing total knee replacement. Studies were at least partially blinded. Three studies had a high risk of performance bias and one a high risk of attrition bias, but the risk of bias was otherwise unclear or low. Only one study assessed joint function using a global score. Due to heterogeneity in outcome and reporting, we could only pool three out of six RCTs, with range of motion assessed at three months after surgery used as a surrogate for joint function. All studies had a high risk of detection bias. Using the random-effects model, there was no statistically significant difference between the experimental and control groups (mean difference 3.99 degrees, 95% confidence interval (CI) − 2.23 to 10.21; P value = 0.21, 3 studies, 140 participants, very low quality evidence). We did not perform further analyses because immediate adverse effects were not part of the explicit outcomes of any of these typically small studies, and long-term adverse events after regional anaesthesia are rare. None of the included studies elicited or reported long-term adverse effects like persistent nerve damage. Authors’ conclusions More high-quality studies are needed to establish the effects of regional analgesia on function after major joint replacement, as well as on the risk of adverse events (falls). PMID:26269416

  19. A systematic review of the relationship between subchondral bone features, pain and structural pathology in peripheral joint osteoarthritis.

    PubMed

    Barr, Andrew J; Campbell, T Mark; Hopkinson, Devan; Kingsbury, Sarah R; Bowes, Mike A; Conaghan, Philip G

    2015-08-25

    Bone is an integral part of the osteoarthritis (OA) process. We conducted a systematic literature review in order to understand the relationship between non-conventional radiographic imaging of subchondral bone, pain, structural pathology and joint replacement in peripheral joint OA. A search of the Medline, EMBASE and Cochrane library databases was performed for original articles reporting association between non-conventional radiographic imaging-assessed subchondral bone pathologies and joint replacement, pain or structural progression in knee, hip, hand, ankle and foot OA. Each association was qualitatively characterised by a synthesis of the data from each analysis based upon study design, adequacy of covariate adjustment and quality scoring. In total 2456 abstracts were screened and 139 papers were included (70 cross-sectional, 71 longitudinal analyses; 116 knee, 15 hip, six hand, two ankle and involved 113 MRI, eight DXA, four CT, eight scintigraphic and eight 2D shape analyses). BMLs, osteophytes and bone shape were independently associated with structural progression or joint replacement. BMLs and bone shape were independently associated with longitudinal change in pain and incident frequent knee pain respectively. Subchondral bone features have independent associations with structural progression, pain and joint replacement in peripheral OA in the hip and hand but especially in the knee. For peripheral OA sites other than the knee, there are fewer associations and independent associations of bone pathologies with these important OA outcomes which may reflect fewer studies; for example the foot and ankle were poorly studied. Subchondral OA bone appears to be a relevant therapeutic target. PROSPERO registration number: CRD 42013005009.

  20. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ankle joint metal/composite semi-constrained... Ankle joint metal/composite semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/composite semi-constrained cemented prosthesis is a device intended to be implanted to replace an...

  1. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer constrained... Knee joint femorotibial metal/polymer constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace part...

  2. 21 CFR 888.3660 - Shoulder joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint metal/polymer semi-constrained... Shoulder joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A shoulder joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a...

  3. 21 CFR 888.3650 - Shoulder joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint metal/polymer non-constrained... Shoulder joint metal/polymer non-constrained cemented prosthesis. (a) Identification. A shoulder joint metal/polymer non-constrained cemented prosthesis is a device intended to be implanted to replace a...

  4. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/composite semi-constrained... Ankle joint metal/composite semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/composite semi-constrained cemented prosthesis is a device intended to be implanted to replace an...

  5. Meat consumption and risk of primary hip and knee joint replacement due to osteoarthritis: a prospective cohort study

    PubMed Central

    2011-01-01

    Background There is emerging evidence for a beneficial effect of meat consumption on the musculoskeletal system. However, whether it affects the risk of knee and hip osteoarthritis is unknown. We performed a prospective cohort study to examine the relationship between meat consumption and risk of primary hip and knee replacement for osteoarthritis. Methods Eligible 35,331 participants were selected from the Melbourne Collaborative Cohort Study recruited during 1990-1994. Consumption of fresh red meat, processed meat, chicken, and fish was assessed using a food frequency questionnaire. Primary hip and knee replacement for osteoarthritis during 2001-2005 was determined by linking the cohort records to the Australian National Joint Replacement Registry. Results There was a negative dose-response relationship between fresh red meat consumption and the risk of hip replacement (hazard ratio (HR) 0.94 per increase in intake of one time/week, 95% confidence interval (CI) 0.89-0.98). In contrast, there was no association with knee replacement risk (HR 0.98, 95% CI 0.94-1.02). Consumption of processed meat, chicken and fish were not associated with risk of hip or knee replacement. Conclusion A high level consumption of fresh red meat was associated with a decreased risk of hip, but not knee, joint replacement for osteoarthritis. One possible mechanism to explain these differential associations may be via an effect of meat intake on bone strength and hip shape. Further confirmatory studies are warranted. PMID:21235820

  6. Meat consumption and risk of primary hip and knee joint replacement due to osteoarthritis: a prospective cohort study.

    PubMed

    Wang, Yuanyuan; Simpson, Julie Anne; Wluka, Anita E; English, Dallas R; Giles, Graham G; Graves, Stephen; Cicuttini, Flavia M

    2011-01-16

    There is emerging evidence for a beneficial effect of meat consumption on the musculoskeletal system. However, whether it affects the risk of knee and hip osteoarthritis is unknown. We performed a prospective cohort study to examine the relationship between meat consumption and risk of primary hip and knee replacement for osteoarthritis. Eligible 35,331 participants were selected from the Melbourne Collaborative Cohort Study recruited during 1990-1994. Consumption of fresh red meat, processed meat, chicken, and fish was assessed using a food frequency questionnaire. Primary hip and knee replacement for osteoarthritis during 2001-2005 was determined by linking the cohort records to the Australian National Joint Replacement Registry. There was a negative dose-response relationship between fresh red meat consumption and the risk of hip replacement (hazard ratio (HR) 0.94 per increase in intake of one time/week, 95% confidence interval (CI) 0.89-0.98). In contrast, there was no association with knee replacement risk (HR 0.98, 95% CI 0.94-1.02). Consumption of processed meat, chicken and fish were not associated with risk of hip or knee replacement. A high level consumption of fresh red meat was associated with a decreased risk of hip, but not knee, joint replacement for osteoarthritis. One possible mechanism to explain these differential associations may be via an effect of meat intake on bone strength and hip shape. Further confirmatory studies are warranted.

  7. Proceedings of the Organization of 1990 Meeting of International Neural Network Society Jointed with IEEE Held in Washington, DC on January 15 - 19, 1990. Volume 2. Applications Track.

    DTIC Science & Technology

    1990-11-30

    Simonotto Universita’ di Genova Learning from Natural Selection in an Artificial Environment ...................................................... 1...11-92 Ethem Alpaydin Swiss Federal Institute of Technology Framework for Distributed Artificial Neural System Simulation...11-129 David Y. Fong Lockheed Missiles and Space Co. and Christopher Tocci Raytheon Co. Simulation of Artificial Neural

  8. Moje first metatarsophalangeal replacement--a case series with functional outcomes using the AOFAS-HMI score.

    PubMed

    Brewster, Mark; McArthur, John; Mauffrey, Cyril; Lewis, Andrew Charles; Hull, Peter; Ramos, James

    2010-01-01

    We report the functional results of a case series of Moje first metatarsophalangeal total joint replacements carried out between February 2001 and November 2006. All patients who underwent Moje arthroplasty under the care of a single surgeon were included; outcome scores and complications were recorded annually. A total of 32 joints in 29 consecutive patients were followed for a mean duration of 34 (range 6 to 74) months, and the mean patient age at the time of operation was 56 (range 38 to 79) years. Hallux rigidus was the primary diagnosis in 28 (87.5%) of the cases. The mean American Orthopaedic Foot & Ankle Society Hallux-Metatarsophalangeal-Interphalangeal score at final follow-up was 74/100 (range 9 to 100), with 13 (40.63%) joints rated good to excellent. Two (6.25%) joints were revised to arthrodesis at a mean of 52 (range 41 to 63) months following the arthroplasty procedure, and the overall prevalence of postoperative complications was 6 (18.75%). Based on these results, we concluded that first MTPJ total joint replacement with the Moje device remains promising, but still has room for improvement before the results match those obtained with larger joint (knee, hip) arthroplasty. Copyright 2010 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Patients with Staged Bilateral Total Joint Arthroplasty in Registries: Immortal Time Bias and Methodological Options.

    PubMed

    van der Pas, Stéphanie L; Nelissen, Rob G H H; Fiocco, Marta

    2017-08-02

    In arthroplasty data, patients with staged bilateral total joint arthroplasty (TJA) pose a problem in statistical analysis. Subgroup analysis, in which patients with unilateral and bilateral TJA are studied separately, is sometimes considered an appropriate solution to the problem; we aim to show that this is not true because of immortal time bias. We reviewed patients who underwent staged (at any time) bilateral TJA. The logical fallacy leading to immortal time bias is explained through a simple artificial data example. The cumulative incidences of revision and death are computed by subgroup analysis and by landmark analysis based on hip replacement data from the Dutch Arthroplasty Register and on simulated data sets. For patients who underwent unilateral TJA, subgroup analysis can lead to an overestimate of the cumulative incidence of death and an underestimate of the cumulative incidence of revision. The reverse conclusion holds for patients who underwent staged bilateral TJA. Analysis of these patients can lead to an underestimate of the cumulative incidence of death and an overestimate of the cumulative incidence of revision. Immortal time bias can be prevented by using landmark analysis. When examining arthroplasty registry data, patients who underwent staged bilateral TJA should be analyzed with caution. An appropriate statistical method to address the research question should be selected.

  10. In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators.

    PubMed

    Yan, Yu; Dowson, Duncan; Neville, Anne

    2013-02-01

    The second generation Metal-on-Metal (MoM) hip replacements have been considered as an alternative to commonly used Polyethylene-on-Metal (PoM) joint prostheses due to polyethylene wear debris induced osteolysis. However, the role of corrosion and the biofilm formed under tribological contact are still not fully understood. Enhanced metal ion concentrations have been reported widely from hair, blood and urine samples of patients who received metal hip replacements and in isolated cases when abnormally high levels have caused adverse local tissue reactions. An understanding of the origin of metal ions is really important in order to design alloys for reduced ion release. Reciprocating pin-on-plate wear tester is a standard instrument to assess the interaction of corrosion and wear. However, more realistic hip simulator can provide a better understanding of tribocorrosion process for hip implants. It is very important to instrument the conventional hip simulator to enable electrochemical measurements. In this study, simple reciprocating pin-on-plate wear tests and hip simulator tests were compared. It was found that metal ions originated from two sources: (a) a depassivation of the contacting surfaces due to tribology (rubbing) and (b) corrosion of nano-sized wear particles generated from the contacting surfaces. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. [Distal fixation prosthesis for unstable intertrochanteric fractures in elderly patients: a mid-term follow-up study].

    PubMed

    Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan

    2016-06-01

    To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly patients, hip joint function in patients aged more than 80 years old is worse, while there was no obvious market effect in fracture classification, whether to use tension band and type of distal fixation prosthesis, moreover, proximal femoral osteolysis should be focused on.

  12. First metatarsophalangeal joint replacement with modular three-component press-fit implant. Preliminary report.

    PubMed

    Kolodziej, L; Bohatyrewicz, A; Zietek, P

    2013-01-01

    The aim of this retrospective study was to assess functional and radiographic results of the first metatarsophalangeal joint replacement with use of unconstrained, modular, three components, porous titanium and hydroxyapatite coated, press-fit METIS® prosthesis. According to author's knowledge, results of that type of prosthesis have never been published before. 25 prosthesis were implanted in 24 patients between February 2009 and May 2011. American Orthopaedic Foot and Ankle Society Hallux Metatarsophalangeal Interphalangeal scoring system (AOFAS-HMI) was used to assess functional results. Patients were also asked if they would undergo procedure again or recommend it to other people. Weight bearing radiographs ware made at final follow up and analyzed for presence of osteolysis and radiolucencies. In 8 patients total joint replacement was introduced as a salvage after failure of previous surgery like Keller resection arthroplasty, failed arthrodesis, avascular necrosis and postoperative arthritis. In 11 patients the reason for prosthetic replacement were hallux rigidus, in 4 cases rheumatoid arthritis and gout in one patient. In two patients additional procedures like Akin phalangeal osteotomy and in one case fifth metatarsal osteotomy, was performed. There were 20 females and 4 males in presented group. The mean age at the operation was 56 years. The average follow up period was 18 months (from 12 to 36 months). The median postoperative value of AOFAS-HMI scores was 88 points (from 75 to 95 points). First metatarsophalangeal joint motion (dorsiflexion plus plantarflexion) was classified according to AOFAS-HMI ranges as: moderately restricted (between 30 to 70 degrees) in 19 patients 80% (20 prosthesis) and severely restricted (less then 30 degrees) in 5 patients (20%). 15 (64%) patients were completely satisfied, 5 (20%) reported moderate satisfaction and (16%) 4 were totally disappointed and would not undergo this procedure again. A limited hallux dorsiflexion was the main dissatisfaction reason. Partial radiolucent line was seen in one patient (4%). Authors noticed two serious complications. In one patient, with rheumatoid arthritis, deep infection occurred 12 months after prosthesis implantation. In second case phalangeal implant was revised due to misalignment. METIS® metatarsophalangeal joint replacement allows alleviate of pain relating to hallux rigidus and partial restoration of joint movement, even in patients after failures of primary metatarsophalangeal joint surgery. AOFAS-HMI results are better than previously reported in the literature in assessment of the first metatarsophalangeal joint replacement. Radiographic results imply satisfactory bone ingrowth into the cementless implants.

  13. Comparison of the effects of forefoot joint-preserving arthroplasty and resection-replacement arthroplasty on walking plantar pressure distribution and patient-based outcomes in patients with rheumatoid arthritis.

    PubMed

    Ebina, Kosuke; Hirao, Makoto; Takagi, Keishi; Ueno, Sachi; Morimoto, Tokimitsu; Matsuoka, Hozo; Kitaguchi, Kazuma; Iwahashi, Toru; Hashimoto, Jun; Yoshikawa, Hideki

    2017-01-01

    The purpose of this retrospective study is to clarify the difference in plantar pressure distribution during walking and related patient-based outcomes between forefoot joint-preserving arthroplasty and resection-replacement arthroplasty in patients with rheumatoid arthritis (RA). Four groups of patients were recruited. Group1 included 22 feet of 11 healthy controls (age 48.6 years), Group2 included 36 feet of 28 RA patients with deformed non-operated feet (age 64.8 years, Disease activity score assessing 28 joints with CRP [DAS28-CRP] 2.3), Group3 included 27 feet of 20 RA patients with metatarsal head resection-replacement arthroplasty (age 60.7 years, post-operative duration 5.6 years, DAS28-CRP 2.4), and Group4 included 34 feet of 29 RA patients with metatarsophalangeal (MTP) joint-preserving arthroplasty (age 64.6 years, post-operative duration 3.2 years, DAS28-CRP 2.3). Patients were cross-sectionally examined by F-SCAN II to evaluate walking plantar pressure, and the self-administered foot evaluation questionnaire (SAFE-Q). Twenty joint-preserving arthroplasty feet were longitudinally examined at both pre- and post-operation. In the 1st MTP joint, Group4 showed higher pressure distribution (13.7%) than Group2 (8.0%) and Group3 (6.7%) (P<0.001). In the 2nd-3rd MTP joint, Group4 showed lower pressure distribution (9.0%) than Group2 (14.5%) (P<0.001) and Group3 (11.5%) (P<0.05). On longitudinal analysis, Group4 showed increased 1st MTP joint pressure (8.5% vs. 14.7%; P<0.001) and decreased 2nd-3rd MTP joint pressure (15.2% vs. 10.7%; P<0.01) distribution. In the SAFE-Q subscale scores, Group4 showed higher scores than Group3 in pain and pain-related scores (84.1 vs. 71.7; P<0.01) and in shoe-related scores (62.5 vs. 43.1; P<0.01). Joint-preserving arthroplasty resulted in higher 1st MTP joint and lower 2nd-3rd MTP joint pressures than resection-replacement arthroplasty, which were associated with better patient-based outcomes.

  14. Development of a Mandibular Motion Simulator for Total Joint Replacement

    PubMed Central

    Celebi, Nukhet; Rohner, E. Carlos; Gateno, Jaime; Noble, Philip C.; Ismaily, Sabir K.; Teichgraeber, John F.; Xia, James J.

    2015-01-01

    Purpose The purpose of this study was to develop a motion simulator capable of recreating and recording the full range of mandibular motions in a cadaveric preparation for an intact temporomandibular joint (TMJ) and after total joint replacement. Material and Methods A human cadaver head was used. Two sets of tracking balls were attached to the forehead and mandible, respectively. Computed tomographic (CT) scan was performed and 3-dimensional CT models of the skull were generated. The cadaver head was then dissected to attach the muscle activation cables and mounted onto the TMJ simulator. Realistic jaw motions were generated through the application of the following muscle forces: lateral pterygoid muscle, suprahyoid depressors (geniohyoid, mylohyoid, and digastric muscles), and elevator muscles. To simulate muscle contraction, cables were inserted into the mandible at the center area of each muscle's attachment. To provide a minimum mouth closing force at the initial position, the elevator muscles were combined at the anterior mandible. During mandibular movement, each motion was recorded using a high-resolution laser scanner. The right TMJ of the same head was reconstructed with a total TMJ prosthesis. The same forces were applied and the jaw motions were recorded again. CT scan was performed and 3-dimensional CT models of the skull with TMJ prosthesis were generated. Results Mandibular motions, before and after TMJ replacement, with and without lateral pterygoid muscle reattachment, were re-created in a cadaveric preparation. The laser-scanned data during the mandibular motion were used to drive 3-dimensional CT models. A movie for each mandibular motion was subsequently created for motion path analysis. Compared with mandibular motion before TMJ replacement, mandibular lateral and protrusive motions after TMJ replacement, with and without lateral pterygoid muscle reattachment, were greatly limited. The jaw motion recorded before total joint replacement was applied to the mandibular and prostheses models after total TMJ replacement. The condylar component was observed sinking into the fossa during jaw motion. Conclusion A motion simulator capable of re-creating and recording full range of mandibular motions in a cadaveric preparation has been developed. It can be used to simulate mandibular motions for the intact TMJ and total joint prosthesis, and to re-create and record their full range of mandibular motions. In addition, the full range of the recorded motion can be re-created as motion images in a computer. These images can be used for motion path analysis and to study the causation of limited range of motion after total joint replacement and strategies for improvement. PMID:21050636

  15. The development of artificial organs and prostheses worldwide and in the Ottoman Empire.

    PubMed

    Birdane, Leman; Cingi, Cemal; Elçioğlu, Ömür; Muluk, Nuray Bayar

    2016-08-01

    An artificial organ or prosthesis is a man-made device that is implanted or integrated into a human to replace a natural organ. There were many historical steps in the development of artificial organs and prostheses. New surgical techniques, the development of prosthetic materials and the creative ideas of engineers led to progress in this field. © The European Society of Cardiology 2014.

  16. The use of artificial crabs for testing predatory behavior and health in the octopus.

    PubMed

    Amodio, Piero; Andrews, Paul; Salemme, Marinella; Ponte, Giovanna; Fiorito, Graziano

    2014-01-01

    The willingness of the cephalopod mollusc Octopus vulgaris to attack a live crab is traditionally used as a method to assess the overall health and welfare of octopuses in the laboratory. This method requires placing a crab in the home tank of an animal, measuring the time (latency) taken for the octopus to initiate an attack and withdrawing the crab immediately prior to capture. The same crab is commonly used to assess multiple octopuses as part of daily welfare assessment. Growing concern for the welfare of crustaceans and a review of all laboratory practices for the care and welfare of cephalopods following the inclusion of this taxon in 2010/63/EU prompted a study of the utility of an artificial crab to replace a live crab in the assessment of octopus health. On consecutive days O. vulgaris (N=21) were presented with a live, a dead or an artificial crab, and the latency to attack measured. Despite differences in the predatory performance towards the three different crab alternatives, octopuses readily attacked the artificial (and the dead) crab, showing that they can generalize and respond appropriately towards artificial prey. Researchers should consider using an artificial crab to replace the use of a live crab as part of the routine health assessment of O. vulgaris.

  17. Description of the rates, trends and surgical burden associated with revision for prosthetic joint infection following primary and revision knee replacements in England and Wales: an analysis of the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man.

    PubMed

    Lenguerrand, Erik; Whitehouse, Michael R; Beswick, Andrew D; Toms, Andrew D; Porter, Martyn L; Blom, Ashley W

    2017-07-10

    To describe the prevalence rates of revision surgery for the treatment of prosthetic joint infection (PJI) for patients undergoing knee replacement, their time trends, the cumulative incidence function of revision for PJI and estimate the burden of PJI at health service level. We analysed revision knee replacements performed due to a diagnosis of PJI and the linked index procedures recorded in the National Joint Registry from 2003 to 2014 for England and Wales. The cohort analysed consisted of 679 010 index primary knee replacements, 33 920 index revision knee replacements and 8247 revision total knee replacements performed due to a diagnosis of PJI. The prevalence rates, their time trends investigated by time from index surgery to revision for PJI, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. The incidence of revision total knee replacement due to PJI at 2 years was 3.2/1000 following primary and 14.4/1000 following revision knee replacement, respectively. The prevalence of revision due to PJI in the 3 months following primary knee replacement has risen by 2.5-fold (95% CI 1.2 to 5.3) from 2005 to 2013 and 7.5-fold (95% CI 1.0 to 56.1) following revision knee replacement. Over 1000 procedures per year are performed as a consequence of knee PJI, an increase of 2.8 from 2005 to 2013. Overall, 75% of revisions were two-stage with an increase in use of single-stage from 7.9% in 2005 to 18.8% in 2014. Although the risk of revision due to PJI following knee replacement is low, it is rising, and coupled with the established and further predicted increased incidence of both primary and revision knee replacements, this represents an increasing and substantial treatment burden for orthopaedic service delivery in England and Wales. This has implications for future service design and the funding of individual and specialist centres. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Description of the rates, trends and surgical burden associated with revision for prosthetic joint infection following primary and revision knee replacements in England and Wales: an analysis of the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man

    PubMed Central

    Lenguerrand, Erik; Whitehouse, Michael R; Beswick, Andrew D; Toms, Andrew D; Porter, Martyn L; Blom, Ashley W

    2017-01-01

    Objectives To describe the prevalence rates of revision surgery for the treatment of prosthetic joint infection (PJI) for patients undergoing knee replacement, their time trends, the cumulative incidence function of revision for PJI and estimate the burden of PJI at health service level. Design We analysed revision knee replacements performed due to a diagnosis of PJI and the linked index procedures recorded in the National Joint Registry from 2003 to 2014 for England and Wales. The cohort analysed consisted of 679 010 index primary knee replacements, 33 920 index revision knee replacements and 8247 revision total knee replacements performed due to a diagnosis of PJI. The prevalence rates, their time trends investigated by time from index surgery to revision for PJI, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. Results The incidence of revision total knee replacement due to PJI at 2 years was 3.2/1000 following primary and 14.4/1000 following revision knee replacement, respectively. The prevalence of revision due to PJI in the 3 months following primary knee replacement has risen by 2.5-fold (95% CI 1.2 to 5.3) from 2005 to 2013 and 7.5-fold (95% CI 1.0 to 56.1) following revision knee replacement. Over 1000 procedures per year are performed as a consequence of knee PJI, an increase of 2.8 from 2005 to 2013. Overall, 75% of revisions were two-stage with an increase in use of single-stage from 7.9% in 2005 to 18.8% in 2014. Conclusions Although the risk of revision due to PJI following knee replacement is low, it is rising, and coupled with the established and further predicted increased incidence of both primary and revision knee replacements, this represents an increasing and substantial treatment burden for orthopaedic service delivery in England and Wales. This has implications for future service design and the funding of individual and specialist centres. PMID:28698316

  19. A2-3: Impact of Mild Chronic Kidney Disease Stage on Outcomes after Total Hip or Knee Arthroplasty

    PubMed Central

    Graham, Jove; Deegan, Brian; Bowen, Thomas; Richard, Raveesh; Perkins, Robert; Foltzer, Michael

    2014-01-01

    Background/Aims Dialysis and kidney transplantation adversely impact outcomes of total hip or knee arthroplasty (THA, TKA), but complication rates have not been reported for patients with less advanced stages of chronic kidney disease (CKD). Surgeons lack the data necessary to have informed discussions regarding anticipated outcomes of joint replacement for these patients. Methods We retrospectively reviewed electronic health records of 779 adults with stages 1, 2, and 3 CKD not requiring dialysis or transplantation who underwent THA or TKA from 2004–2011, to assess infection, revision, 90-day readmission and mortality rates. Patients with less than 12 months follow-up, open fracture, prior joint surgery, pregnancy, or acute kidney injury were excluded. Chi-square analysis and Cox survival analysis compared these outcomes between the stage 1–2 and stage 3 groups, stratified by joint replaced (THA vs TKA). All models adjusted for age, sex and BMI at surgery. Results No statistically different rates of revision or infection between Stage 3 vs. Stages 1–2 were seen, although there was a trend toward increased infections in Stage 3. THA patients with Stage 3 showed a significantly increased mortality rate compared to Stage 1–2 THA patients (HR 3.40, 95% CI = 1.25–9.23, P = 0.02). Conclusions CKD affects nearly 15% of the U.S. population many of whom undergo joint replacement. End stage kidney disease (patients post-transplant or on hemodialysis) has been consistently associated with increased rates of infection and revision in excess of our observed outcomes, but the overall rate of infection/revision in our study population was only slightly higher than reported rates in the general population (2–7% vs. 1–2%, respectively). CKD should not preclude joint replacement, but these data can help clinicians engage in meaningful informed discussions with patients with mild kidney disease regarding risks for infection, revision and death following joint replacement.

  20. Cost feasibility of a pre-checking medical tourism system for U.S. patients undertaking joint replacement surgery in Taiwan.

    PubMed

    Haung, Ching-Ying; Wang, Sheng-Pen; Chiang, Chih-Wei

    2010-01-01

    Medical tourism is a relatively recent global economic and political phenomenon that has assumed increasing importance for developing countries, particularly in Asia. In fact, Taiwan possesses a niche for developing medical tourism because many hospitals provide state-of-the-art medicine in all disciplines and many doctors are trained in the United States (US). Among the most common medical procedures outsourced, joint replacements such as total knee replacement (TKR) and total hip replacement (THR) are two surgeries offered to US patients at a lower cost and shorter waiting time than in the US. This paper proposed a pre-checking medical tourism system (PCMTS) and evaluated the cost feasibility of recruiting American clients traveling to Taiwan for joint replacement surgery. Cost analysis was used to estimate the prime costs for each stage in the proposed PCMTS. Sensitivity analysis was implemented to examine how different pricings for medical checking and a surgical operation (MC&SO) and recovery, can influence the surplus per patient considering the PCMTS. Finally, the break-even method was adopted to test the tradeoff between the sunk costs of investment in the PCMTS and the annual surplus for participating hospitals. A novel business plan was built showing that pre-checking stations in medical tourism can provide post-operative care and recovery follow-up. Adjustable pricing for hospital administrators engaged in the PCMTS consisted of two main costs: US$3,700 for MC&SO and US$120 for the hospital stay. Guidelines for pricing were provided to maximize the annual surplus from this plan with different number of patients participating in PCMTS. The maximal profit margin from each American patient undertaking joint surgery is about US$24,315. Using cost analysis, this article might be the first to evaluate the feasibility of PCMTS for joint replacement surgeries. The research framework in this article is applicable when hospital administrators evaluate the feasibility of outsourced medical procedures other than TKR and THR.

  1. Artificial Organs 2015: A Year in Review.

    PubMed

    Malchesky, Paul S

    2016-03-01

    In this Editor's Review, articles published in 2015 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We take this time also to express our gratitude to our authors for providing their work to this journal. We offer our very special thanks to our reviewers who give so generously of their time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers, the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. First results of a polychromatic artificial sodium star for the correction of tilt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman, H.; Foy, R..; Tallon, M.

    1996-03-06

    This paper presents the first results of a joint experiment carried out at Lawrence Livermore National Laboratory during January, 1996. Laser and optical systems were tested to provide a polychromatic artificial sodium star for the correction of tilt. This paper presents the results of that experiment.

  3. 2D joint inversion of CSAMT and magnetic data based on cross-gradient theory

    NASA Astrophysics Data System (ADS)

    Wang, Kun-Peng; Tan, Han-Dong; Wang, Tao

    2017-06-01

    A two-dimensional forward and backward algorithm for the controlled-source audio-frequency magnetotelluric (CSAMT) method is developed to invert data in the entire region (near, transition, and far) and deal with the effects of artificial sources. First, a regularization factor is introduced in the 2D magnetic inversion, and the magnetic susceptibility is updated in logarithmic form so that the inversion magnetic susceptibility is always positive. Second, the joint inversion of the CSAMT and magnetic methods is completed with the introduction of the cross gradient. By searching for the weight of the cross-gradient term in the objective function, the mutual influence between two different physical properties at different locations are avoided. Model tests show that the joint inversion based on cross-gradient theory offers better results than the single-method inversion. The 2D forward and inverse algorithm for CSAMT with source can effectively deal with artificial sources and ensures the reliability of the final joint inversion algorithm.

  4. Alternatives to those artificial FD&C food colorants.

    PubMed

    Wrolstad, Ronald E; Culver, Catherine A

    2012-01-01

    Replacement of artificial food dyes with natural colorants is a current marketing trend, notwithstanding the fact that neither the United States nor the European Union (EU) has defined natural with respect to food colors. Consumer groups have concerns over the safety of synthetic colorants, and in addition, many of the naturally derived colorants provide health benefits. Food scientists frequently have the assignment of replacing artificial colorants with natural alternatives. This can be challenging, as naturally derived colorants are usually less stable, and all desired hues might, in fact, not be obtainable. In this review, the chemical and physical properties, limitations, and more suitable applications for those colorants that are legally available as substitutes for the synthetic colorants are summarized. Issues and challenges for certain foods are discussed, and in addition, colorants that may be available in the future are briefly described.

  5. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... shall be replaced. (c) If a joint bar is cracked or broken between the middle two bolt holes it shall be... in this subpart. (f) No rail shall have a bolt hole which is torch cut or burned. (g) No joint bar...

  6. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... shall be replaced. (c) If a joint bar is cracked or broken between the middle two bolt holes it shall be... in this subpart. (f) No rail shall have a bolt hole which is torch cut or burned. (g) No joint bar...

  7. Artificial organs 2010: a year in review.

    PubMed

    Malchesky, Paul S

    2011-03-01

    In this Editor's Review, articles published in 2010 are organized by category and briefly summarized. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, and the International Society for Rotary Blood Pumps, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level."Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide such meaningful suggestions to the author's work whether eventually accepted or rejected and especially to those whose native tongue is not English. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, Wiley-Blackwell, for their expert attention and support in the production and marketing of Artificial Organs. In this Editor's Review, that historically has been widely received by our readership, we aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. We look forward to recording further advances in the coming years. © 2011, Copyright the Author. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint (hemi-hip) acetabular metal cemented... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip joint...

  9. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  10. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  11. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/composite semi-constrained... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/composite semi-constrained cemented prosthesis is a two-part device intended to be implanted to replace a...

  12. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  13. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  14. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  15. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  16. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  17. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  18. Joint replacement recipients' views about health information privacy.

    PubMed

    Terry, Amanda L; Chesworth, Bert M; Bourne, Robert B; Stolee, Paul; Speechley, Mark

    2015-10-01

    Researchers are concerned about the possibility of restricted access to data as a result of specific consent requirements in privacy legislation, potentially resulting in smaller samples and a lack of representativeness which could bias results. In addition, there is uncertainty about what influences individuals to give consent for the use of their personal health information. To measure joint replacement recipients' health information privacy views and to assess potential predictors of these views. Cross-sectional survey. Potential joint replacement recipients from two teaching hospitals in London, Ontario, Canada. Age, gender, education, employment status, anticipated joint replacement, and expectations for surgery. Privacy concerns as measured by the Concern Scale. The response rate was 182/253 or 72%. The mean Concern score was 143.9/235.0 for the total sample (range = 82-216). Women had higher levels of privacy concerns than men on slightly over half of the individual questionnaire items. In women, surgical joint, age and employment explained 15% of the variance in concerns about personal health information privacy (P = 0.001). The model explained 6% of the variance in concerns in men (P = 0.138) and was not statistically significant. This study indicates that demographic characteristics and health-care experiences play a role in the variability of health information privacy concerns. A greater understanding of patients' privacy views about health information could lead to a greater harmonization among privacy rules, research and data access, and the preferences of health-care consumers. © 2013 John Wiley & Sons Ltd.

  19. Associations between socioeconomic status and primary total knee joint replacements performed for osteoarthritis across Australia 2003-10: data from the Australian Orthopaedic Association National Joint Replacement Registry.

    PubMed

    Brennan, Sharon L; Lane, Stephen E; Lorimer, Michelle; Buchbinder, Rachelle; Wluka, Anita E; Page, Richard S; Osborne, Richard H; Pasco, Julie A; Sanders, Kerrie M; Cashman, Kara; Ebeling, Peter R; Graves, Stephen E

    2014-10-28

    Relatively little is known about the social distribution of total knee joint replacement (TKR) uptake in Australia. We examine associations between socioeconomic status (SES) and TKR performed for diagnosed osteoarthritis 2003-10 for all Australian males and females aged ≥ 30 yr. Data of primary TKR (n=213,018, 57.4% female) were ascertained from a comprehensive national joint replacement registry. Residential addresses were matched to Australian Census data to identify area-level social disadvantage, and categorised into deciles. Estimated TKR rates were calculated. Poisson regression was used to model the relative risk (RR) of age-adjusted TKR per 1,000py, stratified by sex and SES. A negative relationship was observed between TKR rates and SES deciles. Females had a greater rate of TKR than males. Surgery utilisation was greatest for all adults aged 70-79 yr. In that age group differences in estimated TKR per 1,000py between deciles were greater for 2010 than 2003 (females: 2010 RR 4.32 and 2003 RR 3.67; males: 2010 RR 2.04 and 2003 RR 1.78). Identifying factors associated with TKR utilisation and SES may enhance resource planning and promote surgery utilisation for end-stage osteoarthritis.

  20. Effect of total shoulder replacements on airport security screening in the post-9/11 era.

    PubMed

    Dines, Joshua S; Elkousy, Hussein; Edwards, T Bradley; Gartsman, Gary M; Dines, David M

    2007-01-01

    There are few reports in the literature on the effect of orthopaedic implants on airport security devices and none on shoulder arthroplasty implants after September 11, 2001. Since 9/11, airport security screening devices have become more sensitive in response to the increasing threat of terrorism. Often, patients with joint implants activate the metal detectors and are subsequently subjected to more intensive screening. We assess the effects of shoulder joint implants on different airport security devices and what effect the results had on passenger travel. In this study, 154 patients who had previously undergone shoulder replacement responded to a questionnaire regarding their travel experiences after 9/11. Of these, 85 had flown during the time period studied (47 men and 38 women; mean age, 67.8 years); 79 had traveled domestically (mean, 7 flights), and 22 had taken international flights (mean, 6.1 flights). The questionnaire addressed each patient's height/weight, the number of flight segments flown (domestic and international), the number of times that a patient activated the doorway alarm/wand alarm, and the effect of a card stating that the patient had joint replacement (when applicable). On average, patients with shoulder replacement traveling domestically activated the security gate 52% of the time. The average for international travel was 42%. Of the patients who flew both domestically and internationally, there was a high correlation of activation (R = 0.54). Twenty-six patients had multiple joint implants (mean, 2.8). Multiple joint implants caused increased alarm activation (P < .001). All patients reported that their travel was delayed during the instances of security activation. There was no statistically significant effect of body mass index, height, weight, age, or sex on security device activation. Of the patients, 71% were told by their doctor that the shoulder replacement may activate security devices. Of these, 46 were given a card by their doctor indicating the presence of a total joint implant. In only 30% of the security encounters of these patients did the card expedite the screening process. This is the largest study on the effects of joint implants, and shoulder implants in particular, on airport security devices and the only one that has analyzed the data of post-9/11 travel. Patients traveling after total shoulder replacement are often delayed and subjected to more rigorous screening when traveling, especially in the post-9/11 environment. Doctors often warn their patients of potential problems and may try to avert this by giving them cards documenting the presence of a joint implant. The acceptance of these cards is sporadic. This study raises the importance of notifying patients of potential security delays, especially those with multiple joint implants, as they may directly affect travel plans. In addition, these patients may benefit from the establishment of an international joint registry.

  1. The impact of surface and geometry on coefficient of friction of artificial hip joints.

    PubMed

    Choudhury, Dipankar; Vrbka, Martin; Mamat, Azuddin Bin; Stavness, Ian; Roy, Chanchal K; Mootanah, Rajshree; Krupka, Ivan

    2017-08-01

    Coefficient of friction (COF) tests were conducted on 28-mm and 36-mm-diameter hip joint prostheses for four different material combinations, with or without the presence of Ultra High Molecular Weight Polyethylene (UHMWPE) particles using a novel pendulum hip simulator. The effects of three micro dimpled arrays on femoral head against a polyethylene and a metallic cup were also investigated. Clearance played a vital role in the COF of ceramic on polyethylene and ceramic on ceramic artificial hip joints. Micro dimpled metallic femoral heads yielded higher COF against a polyethylene cup; however, with metal on metal prostheses the dimpled arrays significantly reduced the COF. In situ images revealed evidence that the dimple arrays enhanced film formation, which was the main mechanism that contributed to reduced friction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Orthopaedic management of haemophilia arthropathy of the ankle.

    PubMed

    Pasta, G; Forsyth, A; Merchan, C R; Mortazavi, S M J; Silva, M; Mulder, K; Mancuso, E; Perfetto, O; Heim, M; Caviglia, H; Solimeno, L

    2008-07-01

    Joint bleeding, or haemarthrosis, is the most common type of bleeding episode experienced by individuals with haemophilia A and B. This leads to changes within the joints, including synovial proliferation, which results in further bleeding and chronic synovitis. Blood in the joint can also directly damage the cartilage, and with repeated bleeding, there is progressive destruction of both cartilage and bone. The end result is known as haemophilic arthropathy. The joints most commonly affected are the knees, elbows and ankles, although any synovial joint may be involved. In the ankle, both the tibiotalar and subtalar joints may be affected and joint bleeding and arthropathy can lead to a number of deformities. Haemophilic arthropathy can be prevented through regular factor replacement prophylaxis and implementing physiotherapy. However, when necessary, there are multiple surgical and non-surgical options available. In early ankle arthropathy with absent or minimal joint changes, both radioisotopic and chemical synoviorthesis can be used to reduce the hypertrophied synovium. These procedures can decrease the frequency of bleeding episodes, minimizing the risk of articular cartilage damage. Achilles tendon lengthening can be performed, in isolation or in combination with other surgical measures, to correct Achilles tendon contractures. Both arthroscopic and open synovectomies are available as a means to remove the friable villous layer of the synovium and are often indicated when bleeding episodes cannot be properly controlled by factor replacement therapy or synoviorthesis. In the later stages of ankle arthropathy, other surgical options may be considered. Debridement may be indicated when there are loose pieces of cartilage or anterior osteophytes, and can help to improve the joint function, even in the presence of articular cartilage damage. Supramalleolar tibial osteotomy may be indicated in patients with a valgus deformity of the hindfoot without degenerative radiographic findings. Joint fusion, or arthrodesis, is the treatment of choice in the advanced stages of ankle arthropathy although total ankle replacement is currently available. Early ankle replacement components were associated with a poor outcome, but as implant designs have improved, there have been successful outcomes achieved. As the ankle is a commonly affected joint in many individuals with haemophilia, it is important to add to the knowledge base to validate indications and timing of surgical and non-surgical interventions in ankle arthropathy.

  3. Rapid replacement of bridge deck expansion joints study - phase I.

    DOT National Transportation Integrated Search

    2014-12-01

    Bridge deck expansion joints are used to allow for movement of the bridge deck due to thermal expansion, dynamics loading, and : other factors. More recently, expansion joints have also been utilized to prevent the passage of winter de-icing chemical...

  4. Patterned CoCrMo and Al2 O3 surfaces for reduced free wear debris in artificial joint arthroplasty.

    PubMed

    Tarabolsi, Mohamad; Klassen, Thomas; Mantwill, Frank; Gärtner, Frank; Siegel, Frank; Schulz, Arndt-Peter

    2013-12-01

    Surface wear of corresponding tribological pairings is still a major problem in the application of artificial joint surgery. This study aims at developing wear reduced surfaces to utilize them in total joint arthroplasty. Using a pico-second laser, samples of medical CoCrMo metal alloy and Al2 O3 ceramic were patterned by laser material removal. The subsequent tribological investigations employed a ring-on-disc method. The results showed that those samples with modified surfaces show less mass or volume loss than those with a regular, smooth surface. Using calf serum as lubricating medium, the volume loss of the structured CoCrMo samples was eight times lower than that of regular samples. By structuring Al2 O3 surfaces, the wear volume could be reduced by 4.5 times. The results demonstrate that defined surface channels or pits enable the local sedimentation of wear debris. Thus, the amount of free debris could be reduced. Fewer abrasives in the lubricated so-called three-body-wear between the contact surfaces should result in less surface damage. Apart from direct influences on the wear behavior, less amounts of free debris of artificial joints should also be beneficial for avoiding undesired reactions with the surrounding soft tissues. The results from this study are very promising. Future investigations should involve the use of simulators meeting the natural conditions in the joint and in vivo studies with living organisms. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  5. Enhanced lubricant film formation through micro-dimpled hard-on-hard artificial hip joint: An in-situ observation of dimple shape effects.

    PubMed

    Choudhury, Dipankar; Rebenda, David; Sasaki, Shinya; Hekrle, Pavel; Vrbka, Martin; Zou, Min

    2018-05-01

    This study evaluates the impact of dimple shapes on lubricant film formation in artificial hip joints. Micro-dimples with 20-50 µm lateral size and 1 ± 0.2 µm depths were fabricated on CrCoMo hip joint femoral heads using a picosecond laser. Tribological studies were performed using a pendulum hip joint simulator to apply continuous swing flexion-extension motions. The results revealed a significantly enhanced lubricant film thickness (≥ 500 nm) with micro-dimpled prosthesis heads at equilibrium position after the lubricant film has fully developed. The average lubricant film thickness of dimpled prostheses with square- and triangular-shaped dimple arrays over time is about 3.5 that of the non-dimpled prosthesis (204 nm). Remarkably, the prosthesis with square-shaped dimple arrays showed a very fast lubricant film formation reaching their peak values within 0.5 s of pendulum movement, followed by prosthesis with triangular-shaped dimple arrays with a transition period of 42.4 s. The fully developed lubricant film thicknesses (≥ 700 nm) are significantly higher than the surface roughness (≈ 25 nm) demonstrating a hydrodynamic lubrication. Hardly any scratches appeared on the post-experimental prosthesis with square-shaped dimple array and only a few scratches were found on the post-experimental prosthesis with triangular-shaped dimple arrays. Thus, prostheses with square-shaped dimple arrays could be a potential solution for durable artificial hip joints. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Multibody dynamic simulation of knee contact mechanics

    PubMed Central

    Bei, Yanhong; Fregly, Benjamin J.

    2006-01-01

    Multibody dynamic musculoskeletal models capable of predicting muscle forces and joint contact pressures simultaneously would be valuable for studying clinical issues related to knee joint degeneration and restoration. Current three-dimensional multi-body knee models are either quasi-static with deformable contact or dynamic with rigid contact. This study proposes a computationally efficient methodology for combining multibody dynamic simulation methods with a deformable contact knee model. The methodology requires preparation of the articular surface geometry, development of efficient methods to calculate distances between contact surfaces, implementation of an efficient contact solver that accounts for the unique characteristics of human joints, and specification of an application programming interface for integration with any multibody dynamic simulation environment. The current implementation accommodates natural or artificial tibiofemoral joint models, small or large strain contact models, and linear or nonlinear material models. Applications are presented for static analysis (via dynamic simulation) of a natural knee model created from MRI and CT data and dynamic simulation of an artificial knee model produced from manufacturer’s CAD data. Small and large strain natural knee static analyses required 1 min of CPU time and predicted similar contact conditions except for peak pressure, which was higher for the large strain model. Linear and nonlinear artificial knee dynamic simulations required 10 min of CPU time and predicted similar contact force and torque but different contact pressures, which were lower for the nonlinear model due to increased contact area. This methodology provides an important step toward the realization of dynamic musculoskeletal models that can predict in vivo knee joint motion and loading simultaneously. PMID:15564115

  7. Medium-term outcomes and complications after total replacement of the temporomandibular joint. Prospective outcome analysis after 3 and 5 years.

    PubMed

    Gruber, E A; McCullough, J; Sidebottom, A J

    2015-05-01

    In this prospective analysis, we assess the medium-term benefits, efficacy, and safety of the TMJ Concepts joint replacement system in the United Kingdom. Outcome measures of pain, maximum mouth opening, and diet were recorded preoperatively and at intervals up to 3 and 5 years. All patients who had replacement temporomandibular joints (TMJ) within a 6-year period were included. A total of 58 patients (84 joints) were followed up for 3 years (mean age 47, range 19-72) and 26 (42 joints) for 5 years (mean age 46, range 27-70). The female to male ratio was 52:6 at 3 years and 23:3 at 5 years. The most common diagnosis was degenerative disease, and the mean number of previous TMJ procedures was 2.4 (range 0-14). There were significant improvements in pain scores (7.4 reduced to 0.6 at 3 years and 0.8 at 5 years), maximum mouth opening (21.0-35.5mm at 3 years and 23.8-33.7mm at 5 years), and dietary scores (4.1-9.7 at 3 years and 3.7-9.6 at 5 years). Revision operations were required in 2 patients (not included in the outcome data) for biofilm infection of the prosthesis secondary to local infection in the head and neck. One patient had weakness of the temporal branch of the facial nerve that needed correction. TMJ replacement is an effective form of management for an irreparably damaged joint, particularly in cases of ankylosis. It lessens pain and improves function with minimal long-term morbidity. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Readmission Patterns Over 90-Day Episodes of Care Among Medicare Fee-for-Service Beneficiaries Discharged to Post-acute Care.

    PubMed

    Middleton, Addie; Kuo, Yong-Fang; Graham, James E; Karmarkar, Amol; Lin, Yu-Li; Goodwin, James S; Haas, Allen; Ottenbacher, Kenneth J

    2018-04-21

    Examine readmission patterns over 90-day episodes of care in persons discharged from hospitals to post-acute settings. Retrospective cohort study. Acute care hospitals. Medicare fee-for-service enrollees (N = 686,877) discharged from hospitals to post-acute care in 2013-2014. The cohort included beneficiaries >65 years of age hospitalized for stroke, joint replacement, or hip fracture and who survived for 90 days following discharge. 90-day unplanned readmissions. The cohort included 127,680 individuals with stroke, 442,195 undergoing joint replacement, and 117,002 with hip fracture. Thirty-day readmission rates ranged from 3.1% for knee replacement patients discharged to home health agencies (HHAs) to 14.4% for hemorrhagic stroke patients discharged to skilled nursing facilities (SNFs). Ninety-day readmission rates ranged from 5.0% for knee replacement patients discharged to HHAs to 26.1% for hemorrhagic stroke patients discharged to SNFs. Differences in readmission rates decreased between stroke subconditions (hemorrhagic and ischemic) and increased between joint replacement subconditions (knee, elective hip, and nonelective hip) from 30 to 90 days across all initial post-acute discharge settings. We observed clear patterns in readmissions over 90-day episodes of care across post-acute discharge settings and subconditions. Our findings suggest that patients with hemorrhagic stroke may be more vulnerable than those with ischemic over the first 30 days after hospital discharge. For patients receiving nonelective joint replacements, readmission prevention efforts should start immediately after discharge and continue, or even increase, over the 90-day episode of care. Copyright © 2018 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  9. [Implant with a mobile or a fixed bearing in unicompartmental knee joint replacemen].

    PubMed

    Matziolis, G; Tohtz, S; Gengenbach, B; Perka, C

    2007-12-01

    Although the goal of anatomical and functional joint reconstruction in unicompartmental knee replacement is well defined, no uniform implant design has become established. In particular, the differential indications for implantation of an implant with a mobile or a fixed bearing are still not clear. The long-term results of mobile and with fixed bearings are comparable, but there are significant differences in resulting knee joint kinematics, tribological properties and implant-associated complications. In unicompartmental knee replacement mobile bearings restore the physiological joint kinematics better than fixed implants, although the differences to total knee arthroplasty seem minor. The decoupling of mobile bearings from the tibia implant allows a high level of congruence with the femoral implant, resulting in larger contact areas than with fixed bearings. This fact in combination with the more physiological joint kinematics leads to less wear and a lower incidence of osteolyses with mobile bearings. Disadvantages of mobile bearings are the higher complication and early revision rates resulting from bearing dislocation and impingement syndromes caused by suboptimal implantation technique or instability. Especially in cases with ligamentous pathology fixed bearings involve a lower complication rate. It seems their use can also be beneficial in patients with a low level of activity, as problems related to wear are of minor importance for this subgroup. The data currently available allow differentiations between various indications for implants with mobile or fixed bearings, so that the implants can be matched to the patient and the joint pathology in unicompartmental knee joint replacement.

  10. A prospective study on the risk of glove fingertip contamination during draping in joint replacement surgery.

    PubMed

    Makki, D; Deierl, K; Pandit, A; Trakru, S

    2014-09-01

    The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon's grade, the type of procedure, the role of the assistant and the dominance of the hand. A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1-5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection.

  11. Focal hypermobility observed in cervical arthroplasty with Mobi-C.

    PubMed

    Kerferd, Jack William; Abi-Hanna, David; Phan, Kevin; Rao, Prashanth; Mobbs, Ralph J

    2017-12-01

    In recent decades cervical arthroplasty, or cervical disc replacement, has been steadily increasing in popularity as a procedure for the treatment of degenerative pathologies of the cervical spine. This is based on an evolving body of literature that documents superior outcomes in cervical disc replacement over fusion, for both single and double level pathologies, in well selected patients. One of the more recent and popular implants currently on the market is the Mobi-C cervical artificial disc (LDR Medical; Troyes, France). In this paper we report on two cases where focal hypermobility was observed following total disc replacement using the Mobi-C cervical artificial disc. This is followed by a discussion as to potential contributing factors to this hypermobility in relation to both implant design, and operative technique, suggesting potential changes that might prevent this in future patients.

  12. Distraction to treat knee osteoarthritis.

    PubMed

    Flouzat-Lachaniette, Charles-Henri; Roubineau, François; Heyberger, Clémence; Bouthors, Charlie

    2017-03-01

    The objective of this article is to review data on joint distraction used to treat knee osteoarthritis. Joint distraction is a surgical procedure in which the two bony ends of the joint are gradually pulled apart then kept separated for 2 months in an external fixation frame. Weight bearing is continued to ensure variations in hydrostatic pressure within the joint. In published studies, joint distraction provided substantial clinical and structural improvements in patients with knee osteoarthritis, delaying joint replacement surgery for at least 2 years. Animal studies showed that joint distraction was associated with decrease in the secondary inflammatory response, cartilage breakdown, and subchondral bone remodeling. In vitro, the intermittent application of hydrostatic pressure stimulated the production of extracellular matrix, particularly in joints with osteoarthritis. Nevertheless, several considerations invite caution when considering the more widespread use of joint distraction. Published studies have short follow-ups and small sample sizes. In addition, the high frequency of pin tract infection is of concern, since most patients eventually require knee replacement surgery. These two considerations indicate a need for longer-term prospective studies of patient cohorts. Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  13. [Juvenile rheumatoid diseases: Endoprosthetic care of destroyed hip joints].

    PubMed

    Rehart, S; Henniger, M

    2015-07-01

    Patients with juvenile idiopathic arthritis (JIA) often suffer from involvement of the hip joints, with joint destruction and related functional limitations, making hip replacement necessary. To discover what special features are to be expected in patients with JIA and hip arthroplasty and what impact they have on surgical indication, choice of implant, and technique. Selective literature review and evaluation of our patient population. Compared with osteoarthritis patients, JIA patients are on average much younger at the time of hip replacement. Owing to the onset of the disease in childhood or adolescence and the frequent glucocorticoid therapy, growth disorders or abnormal anatomical findings are common in these patients. Bone density is often reduced at an early age. The perioperative management of medication has to be planned. Special implants for patients with rheumatic diseases do not exist, but the above peculiarities of this group of patients should be considered for surgical procedure and choice of implant and material. Overall, the results of hip arthroplasty in juvenile rheumatic diseases, in terms of pain relief and functional improvement, are good. The limited life of the arthroplasty is problematic. By relieving pain, improvement of the range of motion and activity level very high patient satisfaction is usually achieved by hip arthroplasty in JIA patients. In the case of involvement of the contralateral hip or the ipsilateral knee joint it may be useful to perform a simultaneous, single-stage joint replacement of both joints.

  14. Insight into the Tribological Behavior of Liposomes in Artificial Joints.

    PubMed

    Duan, Yiqin; Liu, Yuhong; Zhang, Caixia; Chen, Zhe; Wen, Shizhu

    2016-10-10

    Liposomes are widely used in drug delivery and gene therapy, and their new role as boundary lubricant in natural/artificial joints has been found in recent years. In this study, the tribological properties of liposomes on titanium alloy (Ti6Al4 V)/UHMWPE interface were studied by a ball-on-disc tribometer. The efficient reduction of friction coefficient and wear on both surfaces under various velocities and loads is found. A multilayer structure of physically adsorbed liposomes on Ti6Al4 V surface was also observed by atomic force microscope (AFM). Except for the hydration mechanism by phosphatidylcholine (PC) groups, the well-performed tribological properties by liposomes is also attributed to the existence of adsorbed liposome layers on both surfaces, which could reduce asperities contact and show great bearing capacity. This work enriches the research on liposomes for lubrication improvement on artificial surface and shows their value in clinical application.

  15. The tribology of metal-on-metal total hip replacements.

    PubMed

    Scholes, S C; Unsworth, A

    2006-02-01

    Total hip surgery is an effective way of alleviating the pain and discomfort caused by diseased or damaged joints. However, in the majority of cases, these joints have a finite life. The main reason for failure is osteolysis (bone resorption). It is well documented that an important cause of osteolysis, and therefore the subsequent loosening and failure of conventional metal- or ceramic-on-ultra-high molecular weight polyethylene joints, is the body's immunological response to the polyethylene wear particles. To avoid this, interest has been renewed in metal-on-metal joints. The intention of this paper is to review the studies that have taken place within different laboratories to determine the tribological performance of new-generation metal-on-metal total hip replacements. These types of joint offer a potential solution to enhance the longevity of prosthetic hip systems; however, problems may arise owing to the effects of metal ion release, which are, as yet, not fully understood.

  16. Mandatory bundled payment getting into formation for value-based care.

    PubMed

    Fink, John

    2015-10-01

    Succeeding under Medicare's enterprise Comprehensive Care for Joint Replacement Model will require collaboration among caregivers and financial arrangements to align incentives Priorities for most organization's transition to becoming a value-based hospitals will be care redesign, supply-purchasing strategy, and post-acute care provider partnering. Pursuing value for your joint replacement program will chart a path for other service lines and lead your organization's transition to becoming a value-based enterprise.

  17. On the stiffness matrix of the intervertebral joint: application to total disk replacement.

    PubMed

    O'Reilly, Oliver M; Metzger, Melodie F; Buckley, Jenni M; Moody, David A; Lotz, Jeffrey C

    2009-08-01

    The traditional method of establishing the stiffness matrix associated with an intervertebral joint is valid only for infinitesimal rotations, whereas the rotations featured in spinal motion are often finite. In the present paper, a new formulation of this stiffness matrix is presented, which is valid for finite rotations. This formulation uses Euler angles to parametrize the rotation, an associated basis, which is known as the dual Euler basis, to describe the moments, and it enables a characterization of the nonconservative nature of the joint caused by energy loss in the poroviscoelastic disk and ligamentous support structure. As an application of the formulation, the stiffness matrix of a motion segment is experimentally determined for the case of an intact intervertebral disk and compared with the matrices associated with the same segment after the insertion of a total disk replacement system. In this manner, the matrix is used to quantify the changes in the intervertebral kinetics associated with total disk replacements. As a result, this paper presents the first such characterization of the kinetics of a total disk replacement.

  18. Risk factors for renal dysfunction after total knee joint replacement.

    PubMed

    Hassan, Basim K; Sahlström, Arne; Dessau, Ram B

    2015-12-01

    Renal injury and dysfunction are serious complications after major surgery, which may lead to increased morbidity and mortality. The objective of our study was to identify the possible risk factors for renal dysfunction after total knee joint replacement. A retrospective study was conducted among 702 consecutive primary knee joint replacements performed between January 2009 and December 2012 in our department. Increased postoperative serum creatinine was considered indicative of postoperative renal injury according to RIFLE criteria. Sixty three patients (9.7%) had significant moderate or severe postoperative renal dysfunction in which 8 patients (1.2%) ended with severe and permanent renal impairment. Advanced age, low intraoperative blood pressure, hypertension, general anaesthesia, and prophylactic dicloxacillin were identified as significant risk factors. Male gender and BMI were independent risk factors for postoperative increase in serum creatinine. Smoking, female gender, diabetes mellitus and duration of surgery were not identified as significant risk factors.

  19. Ethnicity and patient's perception of risk in joint replacement surgery.

    PubMed

    Gandhi, Rajiv; Razak, Fahad; Davey, J Roderick; Mahomed, Nizar N

    2008-08-01

    Despite much evidence showing racial disparities in the use of surgical procedures, it is unknown whether ethnicity affects perception of surgical risk. We surveyed 1609 patients undergoing primary hip or knee replacement surgery. Relevant covariates including demographic data, body mass index (BMI), sex, comorbidities, education, and ethnicity were recorded. Pain and joint functional status were assessed at baseline and at 1-year followup with the Western Ontario McMaster University Osteoarthritis Index (WOMAC) pain and function scores. Risk perception was assessed with 3 survey questions. Non-European patients had greater functional disability and pain prior to surgery and demonstrated significantly greater perception of risk than European patients (p < 0.001). Independent of other covariates, non-European ethnicity was an independent predictor of a greater perception of risk (p < 0.05). Patient ethnicity is an important factor to consider in understanding a patient's perception of risk in joint replacement surgery.

  20. Implications of the Definition of an Episode of Care Used in the Comprehensive Care for Joint Replacement Model.

    PubMed

    Ellimoottil, Chad; Ryan, Andrew M; Hou, Hechuan; Dupree, James M; Hallstrom, Brian; Miller, David C

    2017-01-01

    Under the Comprehensive Care for Joint Replacement (CJR) model, hospitals are held accountable for nearly all Medicare payments that occur during the initial hospitalization until 90 days after hospital discharge (ie, the episode of care). It is not known whether unrelated expenditures resulting from this "broad" definition of an episode of care will affect participating hospitals' average episode-of-care payments. To compare the CJR program's broad definition of an episode of care with a clinically narrow definition of an episode of care. We identified Medicare claims for 23 251 patients in Michigan who were Medicare beneficiaries and who underwent joint replacement during the period from 2011 through 2013 at hospitals located in metropolitan statistical areas. Using specifications from the CJR model and the clinically narrow Hospital Compare payment measure, we constructed episodes of care and calculated 90-day episode payments. We then compared hospitals' average 90-day episode payments using the 2 definitions of an episode of care and fit linear regression models to understand whether payment differences were associated with specific hospital characteristics (average Centers for Medicare & Medicaid Services-hierarchical condition categories risk score, rural hospital status, joint replacement volume, percentage of Medicaid discharges, teaching hospital status, number of beds, percentage of joint replacements performed on African American patients, and median income of the hospital's county). We performed analyses from July 1 through October 1, 2015. The correlation and difference between average 90-day episode payments using the broad definition of an episode of care in the CJR model and the clinically narrow Hospital Compare definition of an episode of care. We identified 23 251 joint replacements (ie, episodes of care). The 90-day episode payments using the broad definition of the CJR model ranged from $17 349 to $29 465 (mean [SD] payment, $22 122 [$2600]). Episode payments were slightly lower (mean payment, $21 670) when the Hospital Compare definition was used. Both methods were strongly correlated (r = 0.99, P < .001). The average payment difference between these 2 types of episodes of care was small (mean [SD], $452 [$177]; range, $73-$1006). In our multivariable analysis, we found that the hospital characteristics examined had a minimal impact or no impact on the payment differential. The average 90-day episode payments determined by both definitions of an episode of care were strongly correlated, and there was a small payment differential for most hospitals. In the context of joint replacement bundled payments, these data suggest that hospital performance will be consistent whether a broad or clinically narrow definition of an episode of care is used.

  1. Artificial Organs 2013: a year in review.

    PubMed

    Malchesky, Paul S

    2014-03-01

    In this Editor's Review, articles published in 2013 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level". Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide so meaningful suggestions to the author's work whether eventually accepted or rejected and especially to those whose native tongue is not English. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, Wiley Periodicals, for their expert attention and support in the production and marketing of Artificial Organs. We look forward to recording further advances in the coming years. © 2014 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  2. Effect of progressive wear on the contact mechanics of hip replacements--does the realistic surface profile matter?

    PubMed

    Wang, Ling; Yang, Wenjian; Peng, Xifeng; Li, Dichen; Dong, Shuangpeng; Zhang, Shu; Zhu, Jinyu; Jin, Zhongmin

    2015-04-13

    The contact mechanics of artificial metal-on-polyethylene hip joints are believed to affect the lubrication, wear and friction of the articulating surfaces and may lead to the joint loosening. Finite element analysis has been widely used for contact mechanics studies and good agreements have been achieved with current experimental data; however, most studies were carried out with idealist spherical geometries of the hip prostheses rather than the realistic worn surfaces, either for simplification reason or lacking of worn surface profile. In this study, the worn surfaces of the samples from various stages of hip simulator testing (0 to 5 million cycles) were reconstructed as solid models and were applied in the contact mechanics study. The simulator testing results suggested that the center of the head has various departure value from that of the cup and the value of the departure varies with progressively increased wear. This finding was adopted into the finite element study for better evaluation accuracy. Results indicated that the realistic model provided different evaluation from that of the ideal spherical model. Moreover, with the progressively increased wear, large increase of the contact pressure (from 12 to 31 MPa) was predicted on the articulating surface, and the predicted maximum von Mises stress was increased from 7.47 to 13.26 MPa, indicating the marked effect of the worn surface profiles on the contact mechanics of the joint. This study seeks to emphasize the importance of realistic worn surface profile of the acetabular cup especially following large wear volume. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. [Rehabilitation of the patients following the endoprosthetic replacement of the joints of the lower extremities].

    PubMed

    Rud, I M; Melnikova, E A; Rassulova, M A; Razumov, A N; Gorelikov, A E

    2017-12-28

    The present article is the analytical review of the literature pertaining to the problem of rehabilitation of the patients following the endoprosthetic replacement of joints of the lower extremities. The relevance of the problem of interest for medical rehabilitation is beyond any doubt. The traditional methods for the rehabilitation of the patients do not always lead to the desired results. The authors discuss in detail the need for and the contemporary approaches to the rehabilitation of the patients who had undergone reconstructive surgery and arthroplasty of the joints of the lower extremities. The pathogenetically-based three-stage algorithm for medical rehabilitation is proposed.

  4. Hard-on-hard lubrication in the artificial hip under dynamic loading conditions.

    PubMed

    Sonntag, Robert; Reinders, Jörn; Rieger, Johannes S; Heitzmann, Daniel W W; Kretzer, J Philippe

    2013-01-01

    The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal.

  5. Hard-on-Hard Lubrication in the Artificial Hip under Dynamic Loading Conditions

    PubMed Central

    Sonntag, Robert; Reinders, Jörn; Rieger, Johannes S.; Heitzmann, Daniel W. W.; Kretzer, J. Philippe

    2013-01-01

    The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal. PMID:23940772

  6. Taking care of your new knee joint

    MedlinePlus

    Knee arthroplasty - precautions; Knee replacement - precautions ... After you have knee replacement surgery , you will need to be careful about how you move your knee, especially for the first few ...

  7. Shoulder replacement

    MedlinePlus

    ... the opening at the end of the shoulder blade, called the socket. This type of joint allows ... head. The socket part (glenoid) of your shoulder blade will be replaced with a smooth plastic shell ( ...

  8. Patient Use of Cost and Quality Data When Choosing a Joint Replacement Provider in the Context of Reference Pricing

    PubMed Central

    Mehrotra, Ateev; DeVries, Andrea; Wu, Sze-jung; SooHoo, Nelson F.; Martsolf, Grant R.

    2015-01-01

    Health plans are encouraging consumerism among joint replacement patients by reporting information on hospital costs and quality. Little is known about how the proliferation of such initiatives impacts patients’ selection of a surgeon and hospital. We performed a qualitative analysis of semistructured interviews with 13 patients who recently received a hip or knee replacement surgery. Patients focused on the choice of a surgeon as opposed to a hospital, and the surgeon choice was primarily made based on reputation. Most patients had long-standing relationships with an orthopedic surgeon and tended to stay with that surgeon for their replacement. Despite growing availability of cost and quality information, patients almost never used such information to make a decision. PMID:28462261

  9. The Growing Threat of Light Pollution to Ground-Based Observatories

    NASA Astrophysics Data System (ADS)

    Green, Richard F.; Luginbuhl, Christian; Wainscoat, Richard J.; Duriscoe, Dan

    2018-01-01

    With few exceptions, growing sky glow from artificial sources negatively impacts the sky background recorded at major observatories around the world. We report techniques for measuring night sky brightness and extracting the contribution of artificial sky glow at observatories and other protected sites. The increase in artificial ambient light and its changing spectrum with LED replacements is likely to be significant. A compendium of worldwide regulatory approaches to astronomical site protection gives insight on multiple effective strategies.

  10. Artificial dexterous hand

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan (Inventor)

    1990-01-01

    An artificial dexterous hand is provided for conformally engaging and manipulating objects. The hand includes an articulated digit which is connected to an engagement sub-assembly and has a first shape adaption mechanism associated with it. The digit has a digit base and first and second phalanges. The digit base is operatively interconnected to the first phalange by a base joint having a base pulley. The phalanges are operatively interconnected by a separate first phalange joint having a first phalange pulley. The engagement sub-assembly includes a tendon, which is received by the base pulley and by the first phalange pulley, and an actuation device for selectively tensioning the tendon. The first shape adaption mechanism is responsive to and receives the tendon. It is also situated between the base joint and the first phalange joint and is connected to the first phalange. Upon actuation by the actuation device, the phalanges are caused to pivot relative to the base joint and the second phalange is caused to pivot relative to the first phalange. At the same time, the first shape adaption mechanism controls the sequence of the aforementioned pivoting of the phalanges through application of braking force to the tendon.

  11. Effect of Mg and Cu on mechanical properties of high-strength welded joints of aluminum alloys obtained by laser welding

    NASA Astrophysics Data System (ADS)

    Annin, B. D.; Fomin, V. M.; Karpov, E. V.; Malikov, A. G.; Orishich, A. M.

    2017-09-01

    Results of experimental investigations of welded joints of high-strength aluminum-lithium alloys of the Al-Cu-Li and Al-Mg-Li systems are reported. The welded joints are obtained by means of laser welding and are subjected to various types of processing for obtaining high-strength welded joints. A microstructural analysis is performed. The phase composition and mechanical properties of the welded joints before and after heat treatment are studied. It is found that combined heat treatment of the welded joint (annealing, quenching, and artificial ageing) increases the joint strength, but appreciably decreases the alloy strength outside the region thermally affected by the welding process.

  12. Neurological complications of lumbar artificial disc replacement and comparison of clinical results with those related to lumbar arthrodesis in the literature: results of a multicenter, prospective, randomized investigational device exemption study of Charité intervertebral disc. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004.

    PubMed

    Geisler, Fred H; Blumenthal, Scott L; Guyer, Richard D; McAfee, Paul C; Regan, John J; Johnson, J Patrick; Mullin, Bradford

    2004-09-01

    Arthrodesis is the gold standard for surgical treatment of lumbar degenerative disc disease (DDD). Solid fusion, however, can cause stress and increased motion in the segments adjacent to the fused level. This may initiate and/or accelerate the adjacent-segment disease process. Artificial discs are designed to restore and maintain normal motion of the lumbar intervertebral segment. Restoring and maintaining normal motion of the segment reduces stresses and loads on adjacent level segments. A US Food and Drug Administration Investigational Device Exemptions multicentered study of the Charité artificial disc was completed. The control group consisted of individuals who underwent anterior lumbar interbody fusion involving BAK cages and iliac crest bone graft. This is the first report of Class I data in which a lumbar artificial disc is compared with lumbar fusion. Of 304 individuals enrolled in the study, 205 were randomized to the Charité disc-treated group and 99 to the BAK fusion-treated (control) group. Neurological status was equivalent between the two groups at 6, 12, and 24 months postoperatively. The number of patients with major, minor, or other neurological complications was equivalent. There was a greater incidence of both major and minor complications in the BAK fusion group at 0 to 42 days postoperatively. Compared with data reported in the lumbar fusion literature, the Charité disc-treated patients had equivalent or better mean changes in visual analog scale and Oswestry Disability Index scores. The Charité artificial disc is safe and effective for the treatment of single-level lumbar DDD, resulting in no higher incidence of neurological complications compared with BAK-assisted fusion and leading to equivalent or better outcomes compared with those obtained in the control group and those reported in the lumbar fusion literature.

  13. Lipid production of Chlorella vulgaris cultured in artificial wastewater medium.

    PubMed

    Feng, Yujie; Li, Chao; Zhang, Dawei

    2011-01-01

    Chlorella vulgaris was used to study algal lipid production with wastewater treatment. Artificial wastewater was used to cultivate C. vulgaris in a column aeration photobioreactor (CAP) under batch and semi-continuous cultivation with various daily culture replacements (0.5l-1.5l per 2l reactor). The cell density was decreased from 0.89 g/l with the daily replacement of 0.5l to 0.28 g/l with 1.5l replacement. However, C. vulgaris culture achieved the highest lipid content (42%, average value of the phase) and the lipid productivity (147 mg/ld(-1)) with daily replacement of 1.0 l. And then the nutrient removal efficiency were 86% (COD), 97% (NH(4)(+)) and 96% (TP), respectively. Analyses of energy efficiency showed that the net energy ratio (NER) for lipid production with daily replacement of 1.0 l (1.25) was higher than the other volume replacement protocols. And cost analyses showed that the algal biomass can be competitive with petroleum at US$ 63.97 per barrel with the potential credit for wastewater treatment. According to the above results, it is concluded that the present research will lead to an economical technology of algal lipid production. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Position of the prosthesis components in total ankle replacement and the effect on motion at the replaced joint.

    PubMed

    Cenni, Francesco; Leardini, Alberto; Cheli, Andrea; Catani, Fabio; Belvedere, Claudio; Romagnoli, Matteo; Giannini, Sandro

    2012-03-01

    In some cases of total ankle replacement, perfect alignment of the prosthetic components is not achieved. This study analyses the extent to which component positioning is critical for the final range of motion. Fourteen patients undergoing total ankle replacement were assessed preoperatively and postoperatively at seven and 13 months follow-up. X-ray pictures of the ankle were taken in static double leg stance, i.e. at neutral joint position, and in maximum plantarflexion and dorsiflexion. Measurements were obtained by a specially devised computer program based on anatomical reference points digitised on the radiograms. These allowed calculation of the position and orientation of the components in the sagittal and coronal planes, together with the joint range of motion. The mean range of motion was about 34 degrees at the first follow-up and maintained at the second. Tibial and talar components were more anterior than the mid-tibial shaft in 11 and nine patients, respectively. Mean inclination was about four degrees posterior for the tibial component and nearly one degree anterior for the talar component. A significantly larger range of motion was found in ankles both with the talar component located and inclined more anteriorly than the tibial. Correlation, though weak, was found between motion at the replaced ankle and possible residual subluxation and inclination of the components. However, a satisfactory range of motion was also achieved in those patients where recommended locations for the components could not be reached because of the size of the original joint deformity.

  15. [Total artificial heart].

    PubMed

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  16. Quantifying opportunities for hospital cost control: medical device purchasing and patient discharge planning.

    PubMed

    Robinson, James C; Brown, Timothy T

    2014-09-01

    To quantify the potential reduction in hospital costs from adoption of best local practices in supply chain management and discharge planning. We performed multivariate statistical analyses of the association between total variable cost per procedure and medical device price and length of stay, controlling for patient and hospital characteristics. Ten hospitals in 1 major metropolitan area supplied patient-level administrative data on 9778 patients undergoing joint replacement, spine fusion, or cardiac rhythm management (CRM) procedures in 2008 and 2010. The impact on each hospital of matching lowest local market device prices and lowest patient length of stay (LOS) was calculated using multivariate regression analysis controlling for patient demographics, diagnoses, comorbidities, and implications. Average variable costs ranged from $11,315 for joint replacement to $16,087 for CRM and $18,413 for spine fusion. Implantable medical devices accounted for a large share of each procedure's variable costs: 44% for joint replacement, 39% for spine fusion, and 59% for CRM. Device prices and patient length-of-stay exhibited wide variation across hospitals. Total potential hospital cost savings from achieving best local practices in device prices and patient length of stay are 14.5% for joint replacement, 18.8% for spine fusion;,and 29.1% for CRM. Hospitals have opportunities for cost reduction from adoption of best local practices in supply chain management and discharge planning.

  17. Surgery and survival in birth cohorts with severe haemophilia and differences in access to replacement therapy: The Malmö experience.

    PubMed

    Osooli, M; Steen Carlsson, K; Astermark, J; Berntorp, E

    2017-09-01

    Persons with severe haemophilia require lifelong replacement therapy, prophylaxis, to prevent bleeding. Data describing long-term outcomes of prophylactic treatment are scarce. The aim of this study was to investigate joint surgery and survival among persons with severe haemophilia with special attention to access to prophylaxis in the early years of life. Eligible participants had severe haemophilia A or B and were treated at the Malmö centre from the 1960s onward. Time from birth until joint surgery was analysed for participants negative for factor inhibitor and alive in 2000. We compared survival among the entire cohort with severe haemophilia treated at the Malmö centre with the general male population of Sweden and a sample of persons with severe haemophilia from the United Kingdom (UK). Overall, 167 participants were included, 106 (63.5%) of whom had complete data on joint surgery. Among those born before 1970, 1970-1979 and ≥1980 approximately 37%, 21% and 0% had their first joint surgery by age 30, respectively. There were no second joint surgeries reported in cohorts born ≥1970. Persons with severe haemophilia and negative for HIV treated in Malmö have attained approximately similar survival to that of the general male population in Sweden and live slightly longer than persons with severe haemophilia from the UK. Prophylaxis in Sweden, although costly, has markedly improved survival and joint outcomes for persons with severe haemophilia. This study highlights the importance of early start of replacement therapy to prevent or postpone serious joint damage. © 2017 John Wiley & Sons Ltd.

  18. Real-time controller for foot-drop correction by using surface electromyography sensor.

    PubMed

    Al Mashhadany, Yousif I; Abd Rahim, Nasrudin

    2013-04-01

    Foot drop is a disease caused mainly by muscle paralysis, which incapacitates the nerves generating the impulses that control feet in a heel strike. The incapacity may stem from lesions that affect the brain, the spinal cord, or peripheral nerves. The foot becomes dorsiflexed, affecting normal walking. A design and analysis of a controller for such legs is the subject of this article. Surface electromyography electrodes are connected to the skin surface of the human muscle and work on the mechanics of human muscle contraction. The design uses real surface electromyography signals for estimation of the joint angles. Various-speed flexions and extensions of the leg were analyzed. The two phases of the design began with surface electromyography of real human leg electromyography signal, which was subsequently filtered, amplified, and normalized to the maximum amplitude. Parameters extracted from the surface electromyography signal were then used to train an artificial neural network for prediction of the joint angle. The artificial neural network design included various-speed identification of the electromyography signal and estimation of the angles of the knee and ankle joints by a recognition process that depended on the parameters of the real surface electromyography signal measured through real movements. The second phase used artificial neural network estimation of the control signal, for calculation of the electromyography signal to be stimulated for the leg muscle to move the ankle joint. Satisfactory simulation (MATLAB/Simulink version 2012a) and implementation results verified the design feasibility.

  19. A prospective study on the risk of glove fingertip contamination during draping in joint replacement surgery

    PubMed Central

    Deierl, K; Pandit, A; Trakru, S

    2014-01-01

    Introduction The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. Methods During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon’s grade, the type of procedure, the role of the assistant and the dominance of the hand. Results A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1–5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Conclusions Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection. PMID:25198974

  20. Human-technology Integration

    NASA Astrophysics Data System (ADS)

    Mullen, Katharine M.

    Human-technology integration is the replacement of human parts and extension of human capabilities with engineered devices and substrates. Its result is hybrid biological-artificial systems. We discuss here four categories of products furthering human-technology integration: wearable computers, pervasive computing environments, engineered tissues and organs, and prosthetics, and introduce examples of currently realized systems in each category. We then note that realization of a completely artificial sytem via the path of human-technology integration presents the prospect of empirical confirmation of an aware artificially embodied system.

  1. Social support and actual versus expected length of stay in inpatient rehabilitation facilities

    PubMed Central

    Lewis, Zakkoyya H.; Hay, Catherine Cooper; Graham, James E.; Lin, Yu-Li; Karmarkar, Amol M.; Ottenbacher, Kenneth J.

    2016-01-01

    Objectives Describe impairment-specific patterns in shorter- and longer-than-expected lengths of stay in inpatient rehabilitation and examine the independent effects of social support on deviations from expected lengths of stay. Design Retrospective cohort study. Setting Inpatient rehabilitation facilities across the United States. Participants Medicare fee-for-service beneficiaries (N=119,437) who were discharged from inpatient rehabilitation facilities in 2012 following stroke, lower extremity fracture, or lower extremity joint replacement. Intervention Not applicable. Main Outcome Measure Relative length of stay (actual – expected). The Centers for Medicare and Medicaid Services posts annual expected lengths of stay based on patients’ clinical profiles at admission. We created a 3-category outcome variable: short, expected, long. Our primary independent variable (social support) also included 3 categories: family/friends, paid/other, none. Results Mean (SD) actual lengths of stay for joint replacement, fracture, and stroke were 9.8 (3.6), 13.8 (4.5), and 15.8 (7.3) days, respectively; relative lengths of stay were −1.2 (3.1), −1.6 (3.7), and −1.7 (5.2) days. Nearly half of patients (47–48%) were discharged more than 1 day earlier than expected in all 3 groups, whereas 14% of joint replacement, 15% of fracture, and 20% of stroke patients were discharged more than 1 day later than expected. In multinomial regression analysis, using family/friends as the reference group, paid/other support was associated (p<.05) with higher odds of long stays in joint replacement. No social support was associated with lower odds of short stays in all 3 impairment groups and higher odds of long stays in fracture and joint replacement. Conclusion Inpatient rehabilitation experiences and outcomes can be substantially impacted by a patient’s level of social support. More research is needed to better understand these relationships and possible unintended consequences in terms of patient access issues and provider-level quality measures. PMID:27373747

  2. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  3. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  4. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  5. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  6. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  7. How weak values emerge in joint measurements on cloned quantum systems.

    PubMed

    Hofmann, Holger F

    2012-07-13

    A statistical analysis of optimal universal cloning shows that it is possible to identify an ideal (but nonpositive) copying process that faithfully maps all properties of the original Hilbert space onto two separate quantum systems, resulting in perfect correlations for all observables. The joint probabilities for noncommuting measurements on separate clones then correspond to the real parts of the complex joint probabilities observed in weak measurements on a single system, where the measurements on the two clones replace the corresponding sequence of weak measurement and postselection. The imaginary parts of weak measurement statics can be obtained by replacing the cloning process with a partial swap operation. A controlled-swap operation combines both processes, making the complete weak measurement statistics accessible as a well-defined contribution to the joint probabilities of fully resolved projective measurements on the two output systems.

  8. Artificial fusion of the knee joint with intramedullary nail and acrylic cementation following radical excision for tumor.

    PubMed

    Persson, B M; Rydholm, A

    1984-01-01

    Extensive local excisions of skeletal tumors in the knee region create reconstruction problems with several alternative solutions. Custom-made endoprostheses now compete with joint homografts and fusion with autogenous bone-grafts. Artificial fusion utilizing an extra long Küntscher-nail and acrylic cement as a spacer is a fourth possibility with the advantages of immediate ambulation and weight-bearing, here presented in two cases. The expected disadvantages of loosening in long time survivors can be taken care of using one of the above-mentioned alternatives. This revision can be made after completion of adjunctive chemotherapy or later when called for by the occurrence of pain or instability.

  9. Older Person's Guide to Joint Replacement

    MedlinePlus

    ... he or she will refer you to an orthopedic surgeon who does hip and knee replacement surgery. ... The Arthritis Foundation Web The American Academy of Orthopedic Surgeons ' The American Association of Knee and Hip ...

  10. Deciding to have knee or hip replacement

    MedlinePlus

    ... joint replacement surgery References Harkess JW, Crockarell JR. Arthroplasty of the hip. In: Azar FM, Beaty JH, ... Philadelphia, PA: Elsevier; 2017:chap 3. Mihalko WM. Arthroplasty of the knee. In: Azar FM, Beaty JH, ...

  11. Hip Replacement: MedlinePlus Health Topic

    MedlinePlus

    ... damage. The most common cause of damage is osteoarthritis . Osteoarthritis causes pain, swelling, and reduced motion in your ... Food and Drug Administration) Genetics Genetics Home Reference: osteoarthritis (National Library of Medicine) Images Hip joint replacement - ...

  12. [Effect of sterilisation with formaldehyde, gamma irradiation and ethylene oxide on the properties of polyethylene joint replacement components].

    PubMed

    Fulín, P; Pokorný, D; Slouf, M; Vacková, T; Dybal, J; Sosna, A

    2014-01-01

    Each method of sterilisation has some effect on the structure and properties of UHMWPE and thus also on joint replacement longevity. This study was designed to compare, using objective methods of measurement, several kinds of sterilisation and to recommend the one which has the best prospect for making joint replacements last longer. Two groups of UHMWPE samples were tested. Group 1 included virgin GUR 1020 polyethylene, non-modified and non-sterilised (Meditech, Germany). Group 2 comprised of three sets of samples sterilised with formaldehyde, gamma irradiation and ethylene oxide, respectively. In both groups, physicochemical properties were assessed by infrared spectroscopy (IR), and the oxidation (OI) and trans-vinyl (VI) indices, which show the degree of oxidation of a material, were determined. Free-radical concentrations were measured by the method of electron spin resonance (ESR). The mechanical properties of each sample were studied using small punch tests (SPT) and testing microhardness (MH). Any change in mechanical properties can affect, to various degrees, the quality and longevity of a prosthetic joint. The samples sterilised by gamma irradiation showed higher values of both the OI (0.37) and the VI index (0.038) than the other samples (OI, 0.02 to 0.05 and VI, 0). Also, the free-radical concentration was detectable only in the gamma-sterilised sample. Values obtained for mechanical properties were as follows: peak load in the range of 58.48 N (gamma irradiation) to 59.60 N (ethylene oxide); ultimate load in the range of 46.69 N (gamma irradiation) to 57.50 N (ethylene oxide); ultimate displacement in the range of 4.29 mm (gamma irradiation) to 4.58 mm (virgin polyethylene and formaldehyde); and work to failure in the range of 185.18 mJ (gamma irradiation) to 205.89 mJ (virgin polyethylene). Microhardness values were obtained in the following ranges: 41.2 to 44.6 MPa (virgin polyethylene); 40.2 to 44.1 MPa (formaldehyde); 46.1 to 49.3 MPa (gamma irradiation); and 40.3 to 44.2 MPa (ethylene oxide). The samples sterilised with formaldehyde and ethylene oxide have mechanical properties very similar to virgin polyethylene, they are not damaged by oxidation and do not contain free radicals. Owing to these characteristics, the immediate and long-term oxidation stability of the three samples is higher. The sample sterilised by gamma irradiation showed the presence of free radicals and immediate and long-term oxidative degradation. This results in the deterioration of mechanical properties and the growth of crystallinity due to enhanced oxidation and leads to higher polyethylene microhardness. Sterilisation with gamma irradiation results in oxidative degradation and mechanical property deterioration, which is one of the potential risks of a shorter life span of joint replacements. The use of ethylene oxide or formaldehyde does not change polymer properties nor has any effect on oxidation of materials. Therefore, a longer life expectancy of the joint replacements sterilised with ethylene oxide can be expected. The life span of their joint replacements is a key issue for the patients. Prosthetic joint loosening is painful and the patient often requires re-implantation. A higher number of re-implantations is associated with higher costs for the institution involved and, consequently, for the whole health care system. Although this study basically deals with chemical issues, it informs the surgeon of the latest developments leading to the improvement of implanted materials, which can increase the life expectancy of joint replacements and patients' satisfaction.

  13. Aircrew Sizing Survey 2011

    DTIC Science & Technology

    2014-10-01

    Resource JSF Joint Strike Fighter JPATS Joint Primary Aircraft Training System USMC United States Marine Corps USAF United States Air Force LIST...Surface Anthropometry Resource (CAESAR) was developed for the Joint Strike Fighter (JSF) program. The ACSS was intended to replace the JSF-CAESAR...an aircrew sample was made in 2003 by Hudson et al. They extracted a subset, named JSF CAESAR (Joint Strike Fighter), from the Civilian American and

  14. The Effect of Kinematic Conditions and Synovial Fluid Composition on the Frictional Behaviour of Materials for Artificial Joints

    PubMed Central

    Vrbka, Martin; Křupka, Ivan; Hartl, Martin

    2018-01-01

    The paper introduces an experimental investigation of frictional behaviour of materials used for joint replacements. The measurements were performed using a ball-on-disc tribometer, while four material combinations were tested; metal-on-metal, ceramic-on-ceramic, metal-on-polyethylene, and ceramic-on-polyethylene, respectively. The contact was lubricated by pure saline and various protein solutions. The experiments were realized at two mean speeds equal to 5.7 mm/s and 22 mm/s and two slide-to-roll ratios, −150% and 150%. It was found that the implant material is the fundamental parameter affecting friction. In general, the metal pair exhibited approximately two times higher friction compared to the ceramic. In particular, the friction in the case of the metal varied between 0.3 and 0.6 while the ceramic pair exhibited friction within the range from 0.15 to 0.3 at the end of the test. The lowest friction was observed for polyethylene while it decreased to 0.05 under some conditions. It can be also concluded that adding proteins to the lubricant has a positive impact on friction in the case of hard-on-hard pairs. For hard-on-soft pairs, no substantial influence of proteins was observed. The effect of kinematic conditions was found to be negligible in most cases. PMID:29748491

  15. The Effect of Kinematic Conditions and Synovial Fluid Composition on the Frictional Behaviour of Materials for Artificial Joints.

    PubMed

    Nečas, David; Vrbka, Martin; Křupka, Ivan; Hartl, Martin

    2018-05-10

    The paper introduces an experimental investigation of frictional behaviour of materials used for joint replacements. The measurements were performed using a ball-on-disc tribometer, while four material combinations were tested; metal-on-metal, ceramic-on-ceramic, metal-on-polyethylene, and ceramic-on-polyethylene, respectively. The contact was lubricated by pure saline and various protein solutions. The experiments were realized at two mean speeds equal to 5.7 mm/s and 22 mm/s and two slide-to-roll ratios, −150% and 150%. It was found that the implant material is the fundamental parameter affecting friction. In general, the metal pair exhibited approximately two times higher friction compared to the ceramic. In particular, the friction in the case of the metal varied between 0.3 and 0.6 while the ceramic pair exhibited friction within the range from 0.15 to 0.3 at the end of the test. The lowest friction was observed for polyethylene while it decreased to 0.05 under some conditions. It can be also concluded that adding proteins to the lubricant has a positive impact on friction in the case of hard-on-hard pairs. For hard-on-soft pairs, no substantial influence of proteins was observed. The effect of kinematic conditions was found to be negligible in most cases.

  16. Macrophage Integrins Modulate Response to Ultra-High Molecular Weight Polyethylene Particles and Direct Particle-Induced Osteolysis

    PubMed Central

    Zaveri, Toral D.; Dolgova, Natalia V.; Lewis, Jamal S.; Hamaker, Kiri; Clare-Salzler, Michael J.; Keselowsky, Benjamin G.

    2016-01-01

    Aseptic loosening due to peri-prosthetic osteolysis is one of the primary causes for failure of artificial joint replacements. Implant-derived wear particles, often ultra-high molecular weight polyethylene (UHMWPE) microparticles, initiate an inflammatory cascade upon phagocytosis by macrophages, which leads to osteoclast recruitment and activation, ultimately resulting in osteolysis. Investigation into integrin receptors, involved in cellular interactions with biomaterial-adsorbed adhesive proteins, is of interest to understand and modulate inflammatory processes. In this work, we investigate the role of macrophage integrins Mac-1 and RGD-binding integrins in response to UHMWPE wear particles. Using integrin knockout mice as well as integrin blocking techniques, reduction in macrophage phagocytosis and inflammatory cytokine secretion is demonstrated when these receptors are either absent or blocked. Along this line, various opsonizing proteins are shown to differentially modulate microparticle uptake and macrophage secretion of inflammatory cytokines. Furthermore, using a calvarial osteolysis model it is demonstrated that both Mac-1 integrin and RGD-binding integrins modulate the particle induced osteolysis response to UHMWPE microparticles, with a 40% decrease in the area of osteolysis by the absence or blocking of these integrins, in vivo. Altogether, these findings indicate Mac-1 and RGD-binding integrins are involved in macrophage-directed inflammatory responses to UHMWPE and may serve as therapeutic targets to mitigate wear particle induced peri-prosthetic osteolysis for improved performance of implanted joints. PMID:27889664

  17. Long-term follow-up of the experimental replacement of the esophagus with a collagen-silicone composite tube.

    PubMed

    Takimoto, Y; Okumura, N; Nakamura, T; Natsume, T; Shimizu, Y

    1993-01-01

    This study investigated ways of preventing late stenosis after replacing the esophagus with a prosthetic device and increasing survival time in an animal model. In a previous study, the authors induced neoesophageal formation and re-epithelialization at an early stage, although stenosis in the chronic stage remained a problem, and long-term survival was prevented. The authors developed an artificial esophagus made from a collagen-silicone composite tube. The silicone tube (25 mm in diameter, 50 mm long, and 1 mm thick) was covered with collagen sponge (5 mm thick). The collagen sponge was intended to be replaced by host tissue, leading to neoesophageal regeneration. The authors thought stenosis was caused primarily by poor regeneration of submucosal tissue, rather than reepithelialization. Thus, they examined the grade of stenosis relative to the time the stent became dislodged. They concluded that the occurrence of stenosis after anastomosis depends upon the duration of stenting and that stenosis did not develop when the portion replaced by the artificial esophagus was stented for at least 4 weeks.

  18. One-step generation of murine embryonic stem cell-derived mesoderm progenitors and chondrocytes in a serum-free monolayer differentiation system.

    PubMed

    Waese, Elaine Y L; Stanford, William L

    2011-01-01

    Cartilage defects have limited capacity for repair and are often replaced by fibrocartilage with inferior mechanical properties. To overcome the limitations of artificial joint replacement, high-throughput screens (HTS) could be developed to identify molecules that stimulate differentiation and/or proliferation of articular cartilage for drug therapy or tissue engineering. Currently embryonic stem cells (ESCs) can differentiate into articular cartilage by forming aggregates (embryoid body (EB), pellet, micromass), which are difficult to image. We present a novel, single-step method of generating murine ESC-derived chondrocytes in monolayer cultures under chemically defined conditions. Mesoderm induction was achieved in cultures supplemented with BMP4, activin A, or Wnt3a. Prolonged culture with sustained activin A, TGFβ3, or BMP4 supplementation led to robust chondrogenic induction. A short pulse of activin A or BMP4 also induced chondrogenesis efficiently while Wnt3a acted as a later inducer. Long-term supplementation with activin A or with activin A followed by TGFβ3 promoted articular cartilage formation. Thus, we devised a serum-free (SF) culture system to generate ESC-derived chondrocytes without the establishment of 3D cultures or the aid of cell sorting. Cultures were governed by the same signaling pathways as 3D ESC differentiation systems and limb bud mesenchyme or articular cartilage explant cultures. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Novel biological strategies for treatment of wear particle-induced periprosthetic osteolysis of orthopaedic implants for joint replacement

    PubMed Central

    Goodman, S. B.; Gibon, E.; Pajarinen, J.; Lin, T.-H.; Keeney, M.; Ren, P.-G.; Nich, C.; Yao, Z.; Egashira, K.; Yang, F.; Konttinen, Y. T.

    2014-01-01

    Wear particles and by-products from joint replacements and other orthopaedic implants may result in a local chronic inflammatory and foreign body reaction. This may lead to persistent synovitis resulting in joint pain and swelling, periprosthetic osteolysis, implant loosening and pathologic fracture. Strategies to modulate the adverse effects of wear debris may improve the function and longevity of joint replacements and other orthopaedic implants, potentially delaying or avoiding complex revision surgical procedures. Three novel biological strategies to mitigate the chronic inflammatory reaction to orthopaedic wear particles are reported. These include (i) interference with systemic macrophage trafficking to the local implant site, (ii) modulation of macrophages from an M1 (pro-inflammatory) to an M2 (anti-inflammatory, pro-tissue healing) phenotype in the periprosthetic tissues, and (iii) local inhibition of the transcription factor nuclear factor kappa B (NF-κB) by delivery of an NF-κB decoy oligodeoxynucleotide, thereby interfering with the production of pro-inflammatory mediators. These three approaches have been shown to be viable strategies for mitigating the undesirable effects of wear particles in preclinical studies. Targeted local delivery of specific biologics may potentially extend the lifetime of orthopaedic implants. PMID:24478281

  20. Cross-Shear Implementation in Sliding-Distance-Coupled Finite Element Analysis of Wear in Metal-on-Polyethylene Total Joint Arthroplasty: Intervertebral Total Disc Replacement as an Illustrative Application

    PubMed Central

    Goreham-Voss, Curtis M.; Hyde, Philip J.; Hall, Richard M.; Fisher, John; Brown, Thomas D.

    2010-01-01

    Computational simulations of wear of orthopaedic total joint replacement implants have proven to valuably complement laboratory physical simulators, for pre-clinical estimation of abrasive/adhesive wear propensity. This class of numerical formulations has primarily involved implementation of the Archard/Lancaster relationship, with local wear computed as the product of (finite element) contact stress, sliding speed, and a bearing-couple-dependent wear factor. The present study introduces an augmentation, whereby the influence of interface cross-shearing motion transverse to the prevailing molecular orientation of the polyethylene articular surface is taken into account in assigning the instantaneous local wear factor. The formulation augment is implemented within a widely-utilized commercial finite element software environment (ABAQUS). Using a contemporary metal-on-polyethylene total disc replacement (ProDisc-L) as an illustrative implant, physically validated computational results are presented to document the role of cross-shearing effects in alternative laboratory consensus testing protocols. Going forward, this formulation permits systematically accounting for cross-shear effects in parametric computational wear studies of metal-on-polyethylene joint replacements, heretofore a substantial limitation of such analyses. PMID:20399432

  1. Joint Venture Health Plans May Give ACOs a Run for Their Money.

    PubMed

    Reinke, Thomas

    2016-12-01

    Joint venture plans are starting to demonstrate their ability to implement clinical management and financial management reforms. A JV health plan replaces the offloading of financial risk by health plans to ill-equipped providers with an executive-level cost management committee stated jointly by the hospital and payer.

  2. Effect of Structured Touch and Guided Imagery for Pain and Anxiety in Elective Joint Replacement Patients--A Randomized Controlled Trial: M-TIJRP.

    PubMed

    Forward, John Brent; Greuter, Nancy Elizabeth; Crisall, Santa J; Lester, Houston F

    2015-01-01

    Postoperative management of pain after total joint arthroplasty remains a challenge despite advancements in analgesics. Evidence shows that complementary modalities with mind-body and tactile-based approaches are valid and effective adjuncts to reduce pain and anxiety postoperatively. To investigate the effectiveness of the "M" Technique (M), a registered method of structured touch using a set sequence and number of strokes, and a consistent level of pressure on hands and feet, compared with guided imagery and usual care, for the reduction of pain and anxiety in patients undergoing elective total knee or hip replacement surgery. Randomized controlled trial: M-TIJRP (MiTechnique and guided Imagery in Joint Replacement Patients [Mighty Junior P]). At a community hospital, 225 male and female patients, aged 38 to 90 years, undergoing elective total hip or knee replacement were randomly assigned to 1 of 3 groups (75 patients in each): M, guided imagery, or usual care. They were blinded to their assignment until the intervention. Reduction of pain and anxiety postoperatively. Secondary outcomes measured use of pain medication and patient satisfaction. This study yielded positive findings for the management of pain and anxiety in patients undergoing elective joint replacement using M and guided imagery for 18 to 20 minutes compared with usual care. M showed the largest predicted decreases in both pain and anxiety between groups. There was no significant difference in narcotic pain medication use between groups. Patient satisfaction survey ratings were highest for M, followed by guided imagery. The benefit of M may be because of the specifically structured sequence of touch by competent caring, trained providers.

  3. Effect of Structured Touch and Guided Imagery for Pain and Anxiety in Elective Joint Replacement Patients—A Randomized Controlled Trial: M-TIJRP

    PubMed Central

    Forward, John Brent; Greuter, Nancy Elizabeth; Crisall, Santa J; Lester, Houston F

    2015-01-01

    Context: Postoperative management of pain after total joint arthroplasty remains a challenge despite advancements in analgesics. Evidence shows that complementary modalities with mind-body and tactile-based approaches are valid and effective adjuncts to reduce pain and anxiety postoperatively. Objective: To investigate the effectiveness of the “M” Technique (M), a registered method of structured touch using a set sequence and number of strokes, and a consistent level of pressure on hands and feet, compared with guided imagery and usual care, for the reduction of pain and anxiety in patients undergoing elective total knee or hip replacement surgery. Methods: Randomized controlled trial: M-TIJRP (MiTechnique and guided Imagery in Joint Replacement Patients [Mighty Junior P]). At a community hospital, 225 male and female patients, aged 38 to 90 years, undergoing elective total hip or knee replacement were randomly assigned to 1 of 3 groups (75 patients in each): M, guided imagery, or usual care. They were blinded to their assignment until the intervention. Main Outcome Measures: Reduction of pain and anxiety postoperatively. Secondary outcomes measured use of pain medication and patient satisfaction. Results: This study yielded positive findings for the management of pain and anxiety in patients undergoing elective joint replacement using M and guided imagery for 18 to 20 minutes compared with usual care. M showed the largest predicted decreases in both pain and anxiety between groups. There was no significant difference in narcotic pain medication use between groups. Patient satisfaction survey ratings were highest for M, followed by guided imagery. Conclusion: The benefit of M may be because of the specifically structured sequence of touch by competent caring, trained providers. PMID:26222093

  4. Ranges of motion after reverse shoulder arthroplasty improve significantly the first year after surgery in patients with rheumatoid arthritis.

    PubMed

    Tiusanen, Hannu; Sarantsin, Pjotor; Stenholm, Miika; Mattie, Ryan; Saltychev, Mikhail

    2016-07-01

    To evaluate the trajectory of the change in range of motion after reverse shoulder joint replacement during 3-year follow-up among patients with rheumatoid arthritis. Retrospective cohort longitudinal study of 76 shoulder replacements performed in a university clinic. The range of shoulder motion was assessed by a physiotherapist using a manual goniometer with 5-degree precision before the surgery and 1, 3, 6, 12, and 36 months postoperatively. The shapes of the regression curves suggest that the improvement or decline observed in joint motion was happening mostly during the first year after surgery. After 1 year, the trajectories become flat and they remained unchanged until the end of follow-up. After shoulder joint replacement, the range of shoulder motion showed substantial changes during the first year only. This should be taken into account when scheduling control visits, planning rehabilitation, and predicting the use of community services after the surgery.

  5. Assessment of the Patient-Centered and Family-Centered Care Experience of Total Joint Replacement Patients Using a Shadowing Technique.

    PubMed

    Marcus-Aiyeku, Ulanda; DeBari, Margaret; Salmond, Susan

    2015-01-01

    In 2030, when baby boomers reach 65 years of age and represent 18% of the population, it is anticipated that 67 million adults will have a diagnosis of arthritis increasing the demand for total hip and knee arthroplasty. With the growing emphasis on patient- and family-centered care, the aim of this project was to assess the patient experience of patients and families throughout the entire spectrum of the total joint replacement service line care at a university regional trauma hospital. A shadowing methodology as defined by the Institute for Health Improvement was utilized. Eight patient/family groups undergoing total joint replacements were shadowed. The mapped care experience included time, caregiver, activity, shadower observations, and impressions. Findings revealed inconsistencies in the delivery of patient- and family-centered care. Communication and interactions were predominantly provider-centric, with a focus on care routines versus the patient and family, and anticipation that care would be medically directed.

  6. Wormhole Formation in RSRM Nozzle Joint Backfill

    NASA Technical Reports Server (NTRS)

    Stevens, J.

    2000-01-01

    The RSRM nozzle uses a barrier of RTV rubber upstream of the nozzle O-ring seals. Post flight inspection of the RSRM nozzle continues to reveal occurrence of "wormholes" into the RTV backfill. The term "wormholes", sometimes called "gas paths", indicates a gas flow path not caused by pre-existing voids, but by a little-understood internal failure mode of the material during motor operation. Fundamental understanding of the mechanics of the RSRM nozzle joints during motor operation, nonlinear viscoelastic characterization of the RTV backfill material, identification of the conditions that predispose the RTV to form wormholes, and screening of candidate replacement materials is being pursued by a joint effort between Thiokol Propulsion, NASA, and the Army Propulsion & Structures Directorate at Redstone Arsenal. The performance of the RTV backfill in the joint is controlled by the joint environment. Joint movement, which applies a tension and shear load on the material, coupled with the introduction of high pressure gas in combination create an environment that exceeds the capability of the material to withstand the wormhole effect. Little data exists to evaluate why the material fails under the modeled joint conditions, so an effort to characterize and evaluate the material under these conditions was undertaken. Viscoelastic property data from characterization testing will anchor structural analysis models. Data over a range of temperatures, environmental pressures, and strain rates was used to develop a nonlinear viscoelastic model to predict material performance, develop criteria for replacement materials, and quantify material properties influencing wormhole growth. Three joint simulation analogs were developed to analyze and validate joint thermal barrier (backfill) material performance. Two exploratory tests focus on detection of wormhole failure under specific motor operating conditions. A "validation" test system provides data to "validate" computer models and predictions. Finally, two candidate replacement materials are being screened and "validated" using the developed test systems.

  7. Current Risk Adjustment and Comorbidity Index Underperformance in Predicting Post-Acute Utilization and Hospital Readmissions After Joint Replacements: Implications for Comprehensive Care for Joint Replacement Model.

    PubMed

    Kumar, Amit; Karmarkar, Amol; Downer, Brian; Vashist, Amit; Adhikari, Deepak; Al Snih, Soham; Ottenbacher, Kenneth

    2017-11-01

    To compare the performances of 3 comorbidity indices, the Charlson Comorbidity Index, the Elixhauser Comorbidity Index, and the Centers for Medicare & Medicaid Services (CMS) risk adjustment model, Hierarchical Condition Category (HCC), in predicting post-acute discharge settings and hospital readmission for patients after joint replacement. A retrospective study of Medicare beneficiaries with total knee replacement (TKR) or total hip replacement (THR) discharged from hospitals in 2009-2011 (n = 607,349) was performed. Study outcomes were post-acute discharge setting and unplanned 30-, 60-, and 90-day hospital readmissions. Logistic regression models were built to compare the performance of the 3 comorbidity indices using C statistics. The base model included patient demographics and hospital use. Subsequent models included 1 of the 3 comorbidity indices. Additional multivariable logistic regression models were built to identify individual comorbid conditions associated with high risk of hospital readmissions. The 30-, 60-, and 90-day unplanned hospital readmission rates were 5.3%, 7.2%, and 8.5%, respectively. Patients were most frequently discharged to home health (46.3%), followed by skilled nursing facility (40.9%) and inpatient rehabilitation facility (12.7%). The C statistics for the base model in predicting post-acute discharge setting and 30-, 60-, and 90-day readmission in TKR and THR were between 0.63 and 0.67. Adding the Charlson Comorbidity Index, the Elixhauser Comorbidity Index, or HCC increased the C statistic minimally from the base model for predicting both discharge settings and hospital readmission. The health conditions most frequently associated with hospital readmission were diabetes mellitus, pulmonary disease, arrhythmias, and heart disease. The comorbidity indices and CMS-HCC demonstrated weak discriminatory ability to predict post-acute discharge settings and hospital readmission following joint replacement. © 2017, American College of Rheumatology.

  8. Communications and control for electric power systems: Power system stability applications of artificial neural networks

    NASA Technical Reports Server (NTRS)

    Toomarian, N.; Kirkham, Harold

    1994-01-01

    This report investigates the application of artificial neural networks to the problem of power system stability. The field of artificial intelligence, expert systems, and neural networks is reviewed. Power system operation is discussed with emphasis on stability considerations. Real-time system control has only recently been considered as applicable to stability, using conventional control methods. The report considers the use of artificial neural networks to improve the stability of the power system. The networks are considered as adjuncts and as replacements for existing controllers. The optimal kind of network to use as an adjunct to a generator exciter is discussed.

  9. Identification of patients with suboptimal results after hip arthroplasty: development of a preliminary prediction algorithm.

    PubMed

    Lungu, Eugen; Vendittoli, Pascal-André; Desmeules, François

    2015-10-05

    The ability to predict preoperatively the identity of patients undergoing hip arthroplasty at risk of suboptimal outcomes could help implement interventions targeted at improving surgical results. The objective was to develop a preliminary prediction algorithm (PA) allowing the identification of patients at risk of unsatisfactory outcomes one to two years following hip arthroplasty. Retrospective data on a cohort of 265 patients having undergone primary unilateral hip replacement (188 total arthroplasties and 77 resurfacing arthroplasties) from 2004 to 2010 were collected from our arthroplasty database. Hip pain and function, as measured by the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were collected, as well as self-reported hip joint perception after surgery. Demographic and clinical variables recorded at the time of the surgery were considered as potential predictors. Patients were considered as having a suboptimal surgical outcome if they were in the worst quartile of the postoperative total WOMAC score and perceived their operated hip as artificial with minimal or major limitations. The PA was developed using recursive partitioning. Mean postoperative surgical follow-up was 446 ± 171 days. Forty patients (15.1 %) had a postoperative total WOMAC score in the worst quartile (>11.5/100) and perceived their joint as artificial with minimal or major restrictions. A PA consisting of the following variables achieved the most acceptable level of prediction: gender, age at the time of surgery, body mass index (BMI), and three items of the preoperative WOMAC (degree of pain with walking on a flat surface and during the night as well as degree of difficulty with putting socks or stockings). The rule had a sensitivity of 75.0 % (95 % CI: 59.8-85.8), a specificity of 77.8 % (95 % CI: 71.9-82.7), a positive predictive value of 37.5 % (95 % CI: 27.7-48.5), a negative predictive value of 94.6 % (95 % CI: 90.3-97.0) and positive and negative likelihood ratios of 3.38 (95 % CI: 2.49-4.57) and 0.34 (95 % CI: 0.19-0.55) respectively. The preliminary PA shows promising results at identifying patients at risk of significant functional limitations, increased pain and inadequate joint perception after hip arthroplasty. Clinical use should not be implemented before additional validation and refining.

  10. On the matter of synovial fluid lubrication: implications for Metal-on-Metal hip tribology.

    PubMed

    Myant, Connor; Cann, Philippa

    2014-06-01

    Artificial articular joints present an interesting, and difficult, tribological problem. These bearing contacts undergo complex transient loading and multi axes kinematic cycles, over extremely long periods of time (>10 years). Despite extensive research, wear of the bearing surfaces, particularly metal-metal hips, remains a major problem. Comparatively little is known about the prevailing lubrication mechanism in artificial joints which is a serious gap in our knowledge as this determines film formation and hence wear. In this paper we review the accepted lubrication models for artificial hips and present a new concept to explain film formation with synovial fluid. This model, recently proposed by the authors, suggests that interfacial film formation is determined by rheological changes local to the contact and is driven by aggregation of synovial fluid proteins. The implications of this new mechanism for the tribological performance of new implant designs and the effect of patient synovial fluid properties are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. A Systematic Review of Different Implants and Approaches for Proximal Interphalangeal Joint Arthroplasty

    PubMed Central

    Yamamoto, Michiro; Malay, Sunitha; Fujihara, Yuki; Zhong, Lin; Chung, Kevin C.

    2016-01-01

    Background Outcomes after implant arthroplasty for primary degenerative and posttraumatic osteoarthritis (OA) of proximal interphalangeal (PIP) joint were different according to the implant design and surgical approach. The purpose of this systematic review was to evaluate outcomes of various types of implant arthroplasty for PIP joint OA with emphasis on different surgical approaches. Methods The authors searched all available literature in the PubMed and EMBASE databases for articles reporting on outcomes of implant arthroplasty for PIP joint OA. Data collection included active arc of motion (AOM), extension lag, and complications. We combined the data of various types of surface replacement arthroplasty into one group to compare with silicone arthroplasty. Results A total of 849 articles were screened, yielding 40 studies for final review. The mean postoperative AOM and the mean gain in AOM of silicone implant with volar approach were 58° and 17° respectively which was greater than surface replacement implant with dorsal approach as 51° and 8°, respectively. The mean postoperative extension lag of silicone implant with volar approach and surface replacement with dorsal approach was 5° and 14° respectively. The revision rate of silicone implant with volar approach and surface replacement with dorsal approach was 6% and 18% at the mean follow-up period of 41.2 and 51 months, respectively. Conclusions Silicone implant with volar approach showed the best AOM with less extension lag and fewer complications after surgery among all the implant designs and surgical approaches. PMID:28445369

  12. Biomechanics of the L5-S1 motion segment after total disc replacement - Influence of iatrogenic distraction, implant positioning and preoperative disc height on the range of motion and loading of facet joints.

    PubMed

    Dreischarf, Marcel; Schmidt, Hendrik; Putzier, Michael; Zander, Thomas

    2015-09-18

    Total disc replacement has been introduced to overcome negative side effects of spinal fusion. The amount of iatrogenic distraction, preoperative disc height and implant positioning have been considered important for surgical success. However, their effect on the postoperative range of motion (RoM) and loading of the facets merits further discussion. A validated osteoligamentous finite element model of the lumbosacral spine was employed and extended with four additional models to account for different disc heights. An artificial disc with a fixed center of rotation (CoR) was implemented in L5-S1. In 4000 simulations, the influence of distraction and the CoR's location on the RoM, facet joint forces (FJFs) and facet capsule ligament forces (FCLFs) was investigated. Distraction substantially altered segmental kinematics in the sagittal plane by decreasing range of flexion (0.5° per 1mm of distraction), increasing range of extension (0.7°/mm) and slightly affecting complete sagittal RoM (0.2°/mm). The distraction already strongly increased the FCLFs during surgery (up to 230N) and in flexion (~12N/mm), with higher values in models with larger preoperative disc heights, and increased FJFs in extension. A more anterior implant location decreased the RoM in all planes. In most loading cases, a more posterior location of the implant's CoR increased the FJFs and FCLFs, whereas a more caudal location increased the FCLFs but decreased the FJFs. The results of this study may explain the worse clinical results in patients with overdistraction after TDR. The complete RoM in the sagittal plane appears to be insensitive to detecting surgery-related biomechanical changes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. CONICAL, RADIOGRAPHIC, AND PATIENT-REPORTED RESULTS OF SURFACE REPLACING PROXIMAL INTERPHALANGEAL JOINT ARTHROPLASTY OF THE HAND

    PubMed Central

    Amirtharajah, Mohana; Fufa, Duretti; Lightdale, Nina; Weiland, Andew

    2011-01-01

    The purpose of this study was to evaluate the one-year clinical, radiologic and patient-reported results of surface-replacing proximal interphalangeal joint arthroplasty (SR-PIP) of the hand. Fifteen patients with 18 joints underwent the procedure, and nine patients with 11 joints had follow-up of at least one year's duration. Of these joints, six had a diagnosis of osteoarthritis with no history of trauma, three had post-traumatic arthritis, one had psoriatic arthritis, and one had erosive arthritis. The mean clinical follow-up was at 3.3 years, and the mean radiographic follow-up was at 3.1 years. The average post-operative gain in range of motion at the PIP joint was 28 degrees and was statistically significant. Six patients completed self-reported questionnaires at a mean of 4.8 years post-operatively. The mean Disabilities of the Arm, Shoulder and Hand (DASH) score post-operatively was 17, and the Michigan Hand Questionnaire (MHQ) score for overall satisfaction was 70. There were three complications but only one reoperation. Seven of 11 joints showed some evidence of subsidence on follow-up radiographic examination. However, no joints were revised sec-ondary to loosening. Longer follow-up is needed to determine if this observable radiologic subsidence leads to symptomatic loosening of the implant PMID:22096433

  14. Joint Replacement (Finger and Wrist Joints)

    MedlinePlus

    ... Lawnmower Safety Snowblower safety Pumpkin Carving Gardening Safety Turkey Carving Removing a Ring Fireworks Safety Español Artritis ... Lawnmower Safety Snowblower safety Pumpkin Carving Gardening Safety Turkey Carving Removing a Ring Fireworks Safety Español Artritis ...

  15. [Management of septic arthritis].

    PubMed

    Debrach, Anne-Cécile; Lazarou, Ilias; Gabay, Cem; Uçkay, Ilker

    2018-03-07

    Native joint septic arthritis is a medical emergency requiring urgent joint drainage and antibiotic therapy. In the absence of an artificial joint or a foreign body, the « rheumatological approach » with repetitive arthrocentesis yields similar outcomes in the literature when compared to surgical drainage. Arthrocentesis could therefore be viewed as the preferential method of joint drainage as it is associated both with reduced morbidity for patients and decreased costs for the healthcare system. In case of failure with arthrocentesis, surgical arthroscopic drainage becomes necessary. In addition, the prescription of systemic steroids is promising but requires further studies, especially in adult patient populations.

  16. The Unified Classification System (UCS): improving our understanding of periprosthetic fractures.

    PubMed

    Duncan, C P; Haddad, F S

    2014-06-01

    Periprosthetic fractures are an increasingly common complication following joint replacement. The principles which underpin their evaluation and treatment are common across the musculoskeletal system. The Unified Classification System proposes a rational approach to treatment, regardless of the bone that is broken or the joint involved. ©2014 The British Editorial Society of Bone & Joint Surgery.

  17. Rotational joint assembly for the prosthetic leg

    NASA Technical Reports Server (NTRS)

    Owens, L. J.; Jones, W. C. (Inventor)

    1977-01-01

    A rotational joint assembly for a prosthetic leg has been devised, which enables an artificial foot to rotate slightly when a person is walking, running or turning. The prosthetic leg includes upper and lower tubular members with the rotational joint assembly interposed between them. The assembly includes a restrainer mechanism which consists of a pivotably mounted paddle element. This device applies limiting force to control the rotation of the foot and also restores torque to return the foot back to its initial position.

  18. Design and preliminary biomechanical analysis of artificial cervical joint complex.

    PubMed

    Jian, Yu; Lan-Tao, Liu; Zhao, Jian-ning; Jian-ning, Zhao

    2013-06-01

    To design an artificial cervical joint complex (ACJC) prosthesis for non-fusion reconstruction after cervical subtotal corpectomy, and to evaluate the biomechanical stability, preservation of segment movements and influence on adjacent inter-vertebral movements of this prosthesis. The prosthesis was composed of three parts: the upper/lower joint head and the middle artificial vertebrae made of Cobalt-Chromium-Molybdenum (Co-Cr-Mo) alloy and polyethylene with a ball-and-socket joint design resembling the multi-axial movement in normal inter-vertebral spaces. Biomechanical tests of intact spine (control), Orion locking plate system and ACJC prosthesis were performed on formalin-fixed cervical spine specimens from 21 healthy cadavers to compare stability, range of motion (ROM) of the surgical segment and ROM of adjacent inter-vertebral spaces. As for stability of the whole lower cervical spine, there was no significant difference of flexion, extension, lateral bending and torsion between intact spine group and ACJC prosthesis group. As for segment movements, difference in flexion, lateral bending or torsion between ACJC prosthesis group and control group was not statistically significant, while ACJC prosthesis group showed an increase in extension (P < 0.05) compared to that of the control group. In addition, ACJC prosthesis group demonstrated better flexion, extension and lateral bending compared to those of Orion plating system group (P < 0.05). Difference in adjacent inter-vertebral ROM of the ACJC prosthesis group was not statistically significant compared to that of the control group. After cervical subtotal corpectomy, reconstruction with ACJC prosthesis not only obtained instant stability, but also reserved segment motions effectively, without abnormal gain of mobility at adjacent inter-vertebral spaces.

  19. Evaluation of a musculoskeletal model with prosthetic knee through six experimental gait trials.

    PubMed

    Kia, Mohammad; Stylianou, Antonis P; Guess, Trent M

    2014-03-01

    Knowledge of the forces acting on musculoskeletal joint tissues during movement benefits tissue engineering, artificial joint replacement, and our understanding of ligament and cartilage injury. Computational models can be used to predict these internal forces, but musculoskeletal models that simultaneously calculate muscle force and the resulting loading on joint structures are rare. This study used publicly available gait, skeletal geometry, and instrumented prosthetic knee loading data [1] to evaluate muscle driven forward dynamics simulations of walking. Inputs to the simulation were measured kinematics and outputs included muscle, ground reaction, ligament, and joint contact forces. A full body musculoskeletal model with subject specific lower extremity geometries was developed in the multibody framework. A compliant contact was defined between the prosthetic femoral component and tibia insert geometries. Ligament structures were modeled with a nonlinear force-strain relationship. The model included 45 muscles on the right lower leg. During forward dynamics simulations a feedback control scheme calculated muscle forces using the error signal between the current muscle lengths and the lengths recorded during inverse kinematics simulations. Predicted tibio-femoral contact force, ground reaction forces, and muscle forces were compared to experimental measurements for six different gait trials using three different gait types (normal, trunk sway, and medial thrust). The mean average deviation (MAD) and root mean square deviation (RMSD) over one gait cycle are reported. The muscle driven forward dynamics simulations were computationally efficient and consistently reproduced the inverse kinematics motion. The forward simulations also predicted total knee contact forces (166N

  20. Time-dependent behavior of rough discontinuities under shearing conditions

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Shen, Mingrong; Ding, Wenqi; Jang, Boan; Zhang, Qingzhao

    2018-02-01

    The mechanical properties of rocks are generally controlled by their discontinuities. In this study, the time-dependent behavior of rough artificial joints under shearing conditions was investigated. Based on Barton’s standard profile lines, samples with artificial joint surfaces were prepared and used to conduct the shear and creep tests. The test results showed that the shear strength of discontinuity was linearly related to roughness, and subsequently an empirical equation was established. The long-term strength of discontinuity can be identified using the inflection point of the isocreep-rate curve, and it was linearly related to roughness. Furthermore, the ratio of long-term and instantaneous strength decreased with the increase of roughness. The shear-stiffness coefficient increased with the increase of shear rate, and the influence of shear rate on the shear stiffness coefficient decreased with the decrease of roughness. Further study of the mechanism revealed that these results could be attributed to the different time-dependent behavior of intact and joint rocks.

  1. 49 CFR 213.309 - Restoration or renewal of track under traffic conditions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....g., as in joint bar replacement or rail replacement; (2) Any work that adversely affects the lateral or vertical stability of the track with the exception of spot tamping an isolated condition where not...

  2. 49 CFR 213.309 - Restoration or renewal of track under traffic conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....g., as in joint bar replacement or rail replacement; (2) Any work that adversely affects the lateral or vertical stability of the track with the exception of spot tamping an isolated condition where not...

  3. 49 CFR 213.309 - Restoration or renewal of track under traffic conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....g., as in joint bar replacement or rail replacement; (2) Any work that adversely affects the lateral or vertical stability of the track with the exception of spot tamping an isolated condition where not...

  4. 49 CFR 213.309 - Restoration or renewal of track under traffic conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....g., as in joint bar replacement or rail replacement; (2) Any work that adversely affects the lateral or vertical stability of the track with the exception of spot tamping an isolated condition where not...

  5. Searching for Order Within Chaos: Complexity Theorys Implications to Intelligence Support During Joint Operational Planning

    DTIC Science & Technology

    2017-06-09

    structures constantly arise in firefights and skirmishes on the battlefield. Source: Andrew Ilachinski, Artificial War: Multiagent- Based Simulation of...Alternative Methods of Analysis and Innovative Organizational Structures .” Conference, Rome, Italy March 31-April 2. ...Intelligence Analysis, Joint Operational Planning, Cellular Automata, Agent- Based Modeling 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18

  6. Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints

    PubMed Central

    Nine, Md J.; Choudhury, Dipankar; Hee, Ay Ching; Mootanah, Rajshree; Osman, Noor Azuan Abu

    2014-01-01

    Wear debris, of deferent sizes, shapes and quantities, generated in artificial hip and knees is largely confined to the bone and joint interface. This debris interacts with periprosthetic tissue and may cause aseptic loosening. The purpose of this review is to summarize and collate findings of the recent demonstrations on debris characterization and their biological response that influences the occurrence in implant migration. A systematic review of peer-reviewed literature is performed, based on inclusion and exclusion criteria addressing mainly debris isolation, characterization, and biologic responses. Results show that debris characterization largely depends on their appropriate and accurate isolation protocol. The particles are found to be non-uniform in size and non-homogeneously distributed into the periprosthetic tissues. In addition, the sizes, shapes, and volumes of the particles are influenced by the types of joints, bearing geometry, material combination, and lubricant. Phagocytosis of wear debris is size dependent; high doses of submicron-sized particles induce significant level of secretion of bone resorbing factors. However, articles on wear debris from engineered surfaces (patterned and coated) are lacking. The findings suggest considering debris morphology as an important parameter to evaluate joint simulator and newly developed implant materials. PMID:28788496

  7. Prediction of the Vickers Microhardness and Ultimate Tensile Strength of AA5754 H111 Friction Stir Welding Butt Joints Using Artificial Neural Network.

    PubMed

    De Filippis, Luigi Alberto Ciro; Serio, Livia Maria; Facchini, Francesco; Mummolo, Giovanni; Ludovico, Antonio Domenico

    2016-11-10

    A simulation model was developed for the monitoring, controlling and optimization of the Friction Stir Welding (FSW) process. This approach, using the FSW technique, allows identifying the correlation between the process parameters (input variable) and the mechanical properties (output responses) of the welded AA5754 H111 aluminum plates. The optimization of technological parameters is a basic requirement for increasing the seam quality, since it promotes a stable and defect-free process. Both the tool rotation and the travel speed, the position of the samples extracted from the weld bead and the thermal data, detected with thermographic techniques for on-line control of the joints, were varied to build the experimental plans. The quality of joints was evaluated through destructive and non-destructive tests (visual tests, macro graphic analysis, tensile tests, indentation Vickers hardness tests and t thermographic controls). The simulation model was based on the adoption of the Artificial Neural Networks (ANNs) characterized by back-propagation learning algorithm with different types of architecture, which were able to predict with good reliability the FSW process parameters for the welding of the AA5754 H111 aluminum plates in Butt-Joint configuration.

  8. Intelligent screening of electrofusion-polyethylene joints based on a thermal NDT method

    NASA Astrophysics Data System (ADS)

    Doaei, Marjan; Tavallali, M. Sadegh

    2018-05-01

    The combinations of infrared thermal images and artificial intelligence methods have opened new avenues for pushing the boundaries of available testing methods. Hence, in the current study, a novel thermal non-destructive testing method for polyethylene electrofusion joints was combined with k-means clustering algorithms as an intelligent screening tool. The experiments focused on ovality of pipes in the coupler, as well as misalignment of pipes-couplers in 25 mm diameter joints. The temperature responses of each joint to an internal heat pulse were recorded by an IR thermal camera, and further processed to identify the faulty joints. The results represented clustering accuracy of 92%, as well as more than 90% abnormality detection capabilities.

  9. A neural network approach for determining gait modifications to reduce the contact force in knee joint implant.

    PubMed

    Ardestani, Marzieh Mostafavizadeh; Chen, Zhenxian; Wang, Ling; Lian, Qin; Liu, Yaxiong; He, Jiankang; Li, Dichen; Jin, Zhongmin

    2014-10-01

    There is a growing interest in non-surgical gait rehabilitation treatments to reduce the loading in the knee joint. In particular, synergetic kinematic changes required for joint offloading should be determined individually for each subject. Previous studies for gait rehabilitation designs are typically relied on a "trial-and-error" approach, using multi-body dynamic (MBD) analysis. However MBD is fairly time demanding which prevents it to be used iteratively for each subject. This study employed an artificial neural network to develop a cost-effective computational framework for designing gait rehabilitation patterns. A feed forward artificial neural network (FFANN) was trained based on a number of experimental gait trials obtained from literature. The trained network was then hired to calculate the appropriate kinematic waveforms (output) needed to achieve desired knee joint loading patterns (input). An auxiliary neural network was also developed to update the ground reaction force and moment profiles with respect to the predicted kinematic waveforms. The feasibility and efficiency of the predicted kinematic patterns were then evaluated through MBD analysis. Results showed that FFANN-based predicted kinematics could effectively decrease the total knee joint reaction forces. Peak values of the resultant knee joint forces, with respect to the bodyweight (BW), were reduced by 20% BW and 25% BW in the midstance and the terminal stance phases. Impulse values of the knee joint loading patterns were also decreased by 17% BW*s and 24%BW*s in the corresponding phases. The FFANN-based framework suggested a cost-effective forward solution which directly calculated the kinematic variations needed to implement a given desired knee joint loading pattern. It is therefore expected that this approach provides potential advantages and further insights into knee rehabilitation designs. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Simulation of Blood flow in Artificial Heart Valve Design through Left heart

    NASA Astrophysics Data System (ADS)

    Hafizah Mokhtar, N.; Abas, Aizat

    2018-05-01

    In this work, an artificial heart valve is designed for use in real heart with further consideration on the effect of thrombosis, vorticity, and stress. The design of artificial heart valve model is constructed by Computer-aided design (CAD) modelling and simulated using Computational fluid dynamic (CFD) software. The effect of blood flow pattern, velocity and vorticity of the artificial heart valve design has been analysed in this research work. Based on the results, the artificial heart valve design shows that it has a Doppler velocity index that is less than the allowable standards for the left heart with values of more than 0.30 and less than 2.2. These values are safe to be used as replacement of the human heart valve.

  11. Joint BioEnergy Institute

    ScienceCinema

    Keasling, Jay; Simmons, Blake; Tartaglino, Virginia; Baidoo, Edward; Kothari, Ankita

    2018-05-11

    The Joint BioEnergy Institute (JBEI) is a U.S. Department of Energy (DOE) Bioenergy Research Center dedicated to developing advanced biofuels—liquid fuels derived from the solar energy stored in plant biomass that can replace gasoline, diesel and jet fuels.

  12. Probabilistic modelling to assess exposure to three artificial sweeteners of young Irish patients aged 1-3 years with PKU and CMPA.

    PubMed

    O'Sullivan, Aaron J; Pigat, Sandrine; O'Mahony, Cian; Gibney, Michael J; McKevitt, Aideen I

    2016-11-01

    The choice of suitable normal foods is limited for individuals with particular medical conditions, e.g., inborn errors of metabolism (phenylketonuria - PKU) or severe cow's milk protein allergy (CMPA). Patients may have dietary restrictions and exclusive or partial replacement of specific food groups with specially formulated products to meet particular nutrition requirements. Artificial sweeteners are used to improve the appearance and palatability of such food products to avoid food refusal and ensure dietary adherence. Young children have a higher risk of exceeding acceptable daily intakes for additives than adults due to higher food intakes kg -1 body weight. The Budget Method and EFSA's Food Additives Intake Model (FAIM) are not equipped to assess partial dietary replacement with special formulations as they are built on data from dietary surveys of consumers without special medical requirements impacting the diet. The aim of this study was to explore dietary exposure modelling as a means of estimating the intake of artificial sweeteners by young PKU and CMPA patients aged 1-3 years. An adapted validated probabilistic model (FACET) was used to assess patients' exposure to artificial sweeteners. Food consumption data were derived from the food consumption survey data of healthy young children in Ireland from the National Preschool and Nutrition Survey (NPNS, 2010-11). Specially formulated foods for special medical purposes were included in the exposure model to replace restricted foods. Inclusion was based on recommendations for adequate protein intake and dietary adherence data. Exposure assessment results indicated that young children with PKU and CMPA have higher relative average intakes of artificial sweeteners than healthy young children. The reliability and robustness of the model in the estimation of patient additive exposures was further investigated and provides the first exposure estimates for these special populations.

  13. Hydrogels as a Replacement Material for Damaged Articular Hyaline Cartilage

    PubMed Central

    Beddoes, Charlotte M.; Whitehouse, Michael R.; Briscoe, Wuge H.; Su, Bo

    2016-01-01

    Hyaline cartilage is a strong durable material that lubricates joint movement. Due to its avascular structure, cartilage has a poor self-healing ability, thus, a challenge in joint recovery. When severely damaged, cartilage may need to be replaced. However, currently we are unable to replicate the hyaline cartilage, and as such, alternative materials with considerably different properties are used. This results in undesirable side effects, including inadequate lubrication, wear debris, wear of the opposing articular cartilage, and weakening of the surrounding tissue. With the number of surgeries for cartilage repair increasing, a need for materials that can better mimic cartilage, and support the surrounding material in its typical function, is becoming evident. Here, we present a brief overview of the structure and properties of the hyaline cartilage and the current methods for cartilage repair. We then highlight some of the alternative materials under development as potential methods of repair; this is followed by an overview of the development of tough hydrogels. In particular, double network (DN) hydrogels are a promising replacement material, with continually improving physical properties. These hydrogels are coming closer to replicating the strength and toughness of the hyaline cartilage, while offering excellent lubrication. We conclude by highlighting several different methods of integrating replacement materials with the native joint to ensure stability and optimal behaviour. PMID:28773566

  14. Hydrogels as a Replacement Material for Damaged Articular Hyaline Cartilage.

    PubMed

    Beddoes, Charlotte M; Whitehouse, Michael R; Briscoe, Wuge H; Su, Bo

    2016-06-03

    Hyaline cartilage is a strong durable material that lubricates joint movement. Due to its avascular structure, cartilage has a poor self-healing ability, thus, a challenge in joint recovery. When severely damaged, cartilage may need to be replaced. However, currently we are unable to replicate the hyaline cartilage, and as such, alternative materials with considerably different properties are used. This results in undesirable side effects, including inadequate lubrication, wear debris, wear of the opposing articular cartilage, and weakening of the surrounding tissue. With the number of surgeries for cartilage repair increasing, a need for materials that can better mimic cartilage, and support the surrounding material in its typical function, is becoming evident. Here, we present a brief overview of the structure and properties of the hyaline cartilage and the current methods for cartilage repair. We then highlight some of the alternative materials under development as potential methods of repair; this is followed by an overview of the development of tough hydrogels. In particular, double network (DN) hydrogels are a promising replacement material, with continually improving physical properties. These hydrogels are coming closer to replicating the strength and toughness of the hyaline cartilage, while offering excellent lubrication. We conclude by highlighting several different methods of integrating replacement materials with the native joint to ensure stability and optimal behaviour.

  15. The use of artificial neural networks in experimental data acquisition and aerodynamic design

    NASA Technical Reports Server (NTRS)

    Meade, Andrew J., Jr.

    1991-01-01

    It is proposed that an artificial neural network be used to construct an intelligent data acquisition system. The artificial neural networks (ANN) model has a potential for replacing traditional procedures as well as for use in computational fluid dynamics validation. Potential advantages of the ANN model are listed. As a proof of concept, the author modeled a NACA 0012 airfoil at specific conditions, using the neural network simulator NETS, developed by James Baffes of the NASA Johnson Space Center. The neural network predictions were compared to the actual data. It is concluded that artificial neural networks can provide an elegant and valuable class of mathematical tools for data analysis.

  16. Some aspects of frictional measurements in hip joint simulators.

    PubMed

    Unsworth, Anthony

    2016-05-01

    The measurement of friction in artificial hip joints can lead to the knowledge of the lubrication mechanisms occurring in the joints. However, the measurement of friction, particularly in spherical contacts, is not always straightforward. The important loading and kinematic features must be appropriate and the friction must be measured in the correct plane. Even defining a coefficient of friction is difficult with spherical contacts as friction acts at different moment arms throughout the contact area. Thus, the generated frictional torques depend on the pressure distribution of the contact and the moment arms at which this pressure acts. The pressure distribution depends on the material properties, the surface entraining velocities, the joint diameters, and the clearance between the two surfaces of the ball and socket joint. Equally measuring friction is very taxing for machines which are applying very high loads. Slight misalignments of the application of these loads can produce torques which are very much greater than the frictional torques that we are trying to measure. This article attempts to share the thoughts behind over 40 years of measuring friction in artificial joints using the Durham Friction Simulators. This has led to accrued consistency of measurement and a robust scientific design rationale to understand the nature of friction in these spherical contacts. It also impacts on how to obtain accurate measurements as well as on the understanding of where the difficult issues lie and how to overcome them. © IMechE 2016.

  17. Transverse joint configuration development and testing for a modular bridge deck replacement system.

    DOT National Transportation Integrated Search

    2011-03-01

    According to the 2009 Report Card for Americas Infrastructure, one in four of the nations bridges are listed as : structurally deficient of functionally obsolete, establishing a dire need for new and innovative repair and replacement : techniqu...

  18. Artificial organs 2014: a year in review.

    PubMed

    Malchesky, Paul S

    2015-03-01

    In this Editor's Review, articles published in 2014 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of the International Federation for Artificial Organs, the International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers, the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons, for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Use of a GIS-based hybrid artificial neural network to prioritize the order of pipe replacement in a water distribution network.

    PubMed

    Ho, Cheng-I; Lin, Min-Der; Lo, Shang-Lien

    2010-07-01

    A methodology based on the integration of a seismic-based artificial neural network (ANN) model and a geographic information system (GIS) to assess water leakage and to prioritize pipeline replacement is developed in this work. Qualified pipeline break-event data derived from the Taiwan Water Corporation Pipeline Leakage Repair Management System were analyzed. "Pipe diameter," "pipe material," and "the number of magnitude-3( + ) earthquakes" were employed as the input factors of ANN, while "the number of monthly breaks" was used for the prediction output. This study is the first attempt to manipulate earthquake data in the break-event ANN prediction model. Spatial distribution of the pipeline break-event data was analyzed and visualized by GIS. Through this, the users can swiftly figure out the hotspots of the leakage areas. A northeastern township in Taiwan, frequently affected by earthquakes, is chosen as the case study. Compared to the traditional processes for determining the priorities of pipeline replacement, the methodology developed is more effective and efficient. Likewise, the methodology can overcome the difficulty of prioritizing pipeline replacement even in situations where the break-event records are unavailable.

  20. Efficient rehabilitation care for joint replacement patients: skilled nursing facility or inpatient rehabilitation facility?

    PubMed

    Tian, Wenqiang; DeJong, Gerben; Horn, Susan D; Putman, Koen; Hsieh, Ching-Hui; DaVanzo, Joan E

    2012-01-01

    There has been lengthy debate as to which setting, skilled nursing facility (SNF) or inpatient rehabilitation facility (IRF), is more efficient in treating joint replacement patients. This study aims to determine the efficiency of rehabilitation care provided by SNF and IRF to joint replacement patients with respect to both payment and length of stay (LOS). This study used a prospective multisite observational cohort design. Tobit models were used to examine the association between setting of care and efficiency. The study enrolled 948 knee replacement patients and 618 hip replacement patients from 11 IRFs and 7 SNFs between February 2006 and February 2007. Output was measured by motor functional independence measure (FIM) score at discharge. Efficiency was measured in 3 ways: payment efficiency, LOS efficiency, and stochastic frontier analysis efficiency. IRF patients incurred higher expenditures per case but also achieved larger motor FIM gains in shorter LOS than did SNF patients. Setting of care was not a strong predictor of overall efficiency of rehabilitation care. Great variation in characteristics existed within IRFs or SNFs and severity groups. Medium-volume facilities among both SNFs and IRFs were most efficient. Early rehabilitation was consistently predictive of efficient treatment. The advantage of either setting is not clear-cut. Definition of efficiency depends in part on preference between cost and time. SNFs are more payment efficient; IRFs are more LOS efficient. Variation within SNFs and IRFs blurred setting differences; a simple comparison between SNF and IRF may not be appropriate.

  1. Tuning the superstructure of ultrahigh-molecular-weight polyethylene/low-molecular-weight polyethylene blend for artificial joint application.

    PubMed

    Xu, Ling; Chen, Chen; Zhong, Gan-Ji; Lei, Jun; Xu, Jia-Zhuang; Hsiao, Benjamin S; Li, Zhong-Ming

    2012-03-01

    An easy approach was reported to achieve high mechanical properties of ultrahigh-molecular-weight polyethylene (UHMWPE)-based polyethylene (PE) blend for artificial joint application without the sacrifice of the original excellent wear and fatigue behavior of UHMWPE. The PE blend with desirable fluidity was obtained by melt mixing UHMWPE and low molecular weight polyethylene (LMWPE), and then was processed by a modified injection molding technology-oscillatory shear injection molding (OSIM). Morphological observation of the OSIM PE blend showed LMWPE contained well-defined interlocking shish-kebab self-reinforced superstructure. Addition of a small amount of long chain polyethylene (2 wt %) to LMWPE greatly induced formation of rich shish-kebabs. The ultimate tensile strength considerably increased from 27.6 MPa for conventional compression molded UHMWPE up to 78.4 MPa for OSIM PE blend along the flow direction and up to 33.5 MPa in its transverse direction. The impact strength of OSIM PE blend was increased by 46% and 7% for OSIM PE blend in the direction parallel and vertical to the shear flow, respectively. Wear and fatigue resistance were comparable to conventional compression molded UHMWPE. The superb performance of the OSIM PE blend was originated from formation of rich interlocking shish-kebab superstructure while maintaining unique properties of UHMWPE. The present results suggested the OSIM PE blend has high potential for artificial joint application. © 2012 American Chemical Society

  2. Behavior of single lap composite bolted joint under traction loading: Experimental investigation

    NASA Astrophysics Data System (ADS)

    Awadhani, L. V.; Bewoor, Anand

    2018-04-01

    Composite bolted joints are preferred connection in the composite structures to facilitate the dismantling for the replacements/ maintenance work. The joint behavior under tractive forces has been studied in order to understand the safety of the structure designed. The main objective of this paper is to investigate the behavior of single-lap joints in carbon fiber reinforced epoxy composites under traction loading conditions. The experiments were designed to identify the effect of bolt diameter, stacking sequence and loading rate on the properties of the joint. The experimental results show that the parameters influence the joint performance significantly.

  3. [Reconstruction and balance of soft tissue in hemi-shoulder replacement for patients with four-part fracture of the proximal humerus].

    PubMed

    Wu, Xing; Lou, Lie-ming; Chen, Zheng-rong; Zhang, Guang-jian

    2008-10-01

    To explore the effective skills of reconstruction and balance of soft tissue in hemi-shoulder replacement for patients with four-part fracture of the proximal humerus in order to avoid postoperative complications of joint instability and great tubercle displacement. From June 2002 to June 2006, 25 patients with Neer four-part fracture of the proximal humerus were adopted in the study which included 15 females and 10 males, with the mean age of 66 years (ranged from 56 years to 80 years). They were treated with humeral head replacement and should joint reparation simultaneously by modified operation approach and reconstruction and balance skills of soft tissue. The mean duration of follow-up was 2.3 years (ranged from 1 to 4.5 years). No infection, nerve damage and prosthesis loosing were found in all cases. Two cases of infra-forward dislocation or subluxation occurred due to affected limb placed on abduction splint postoperatively. One case occurred prosthesis upward displacement due to early active abduction exercise but no complains. Neither joint instability nor displacement and malunion of great tubercle were found in other patients. According to Neer scoring system, 6 cases were rated as excellent, 15 as good and 5 as fair. The good and excellent rate was 84%. In hemi-shoulder replacement for patients with Neer four-part fracture the modified operation approach and reconstruction and balance of soft tissue skills combined with rational rehabilitation exercise can prevent postoperative shoulder joint instability and displacement and malunion of great tubercle.

  4. Early mobilization of patients who have had a hip or knee joint replacement reduces length of stay in hospital: a systematic review.

    PubMed

    Guerra, Mark L; Singh, Parminder J; Taylor, Nicholas F

    2015-09-01

    To systematically review the effect of early mobilization after hip or knee joint replacement surgery on length of stay in an acute hospital. Randomized controlled trials were selected from electronic databases based on inclusion criterion requiring an experimental group mobilizing (sitting out of bed/walking) earlier than a comparison group post joint replacement surgery of the hip or knee in an acute hospital. Clinically homogeneous data were analyzed with meta-analysis. Five randomized controlled trials (totaling 622 participants) were included for review. A meta-analysis of 5 trials found a reduced length of stay of 1.8 days (95% confidence interval 1.1 to 2.6) in favor of the experimental group. In 4 of the 5 trials the experimental group first sat out of bed within 24 hours post operatively. In 4 of the 5 trials the experimental group first walked within 48 hours post operatively. Individual trials reported benefits in range of motion, muscle strength and health-related quality of life in favor of the experimental group. There were no differences in discharge destinations, incidence of negative outcomes or adverse events attributable to early mobilization when compared to the comparison groups. Early mobilization post hip or knee joint replacement surgery can result in a reduced length of stay of about 1.8 days. Trials that reported these positive results showed that early mobilization can be achieved within 24 hours of operation. This positive gain was achieved without an increase in negative outcomes. © The Author(s) 2014.

  5. A Systematic Review of Different Implants and Approaches for Proximal Interphalangeal Joint Arthroplasty.

    PubMed

    Yamamoto, Michiro; Malay, Sunitha; Fujihara, Yuki; Zhong, Lin; Chung, Kevin C

    2017-05-01

    Outcomes after implant arthroplasty for primary degenerative and posttraumatic osteoarthritis of the proximal interphalangeal joint were different according to the implant design and surgical approach. The purpose of this systematic review was to evaluate outcomes of various types of implant arthroplasty for proximal interphalangeal joint osteoarthritis, with an emphasis on different surgical approaches. The authors searched all available literature in the PubMed and EMBASE databases for articles reporting on outcomes of implant arthroplasty for proximal interphalangeal joint osteoarthritis. Data collection included active arc of motion, extension lag, and complications. The authors combined the data of various types of surface replacement arthroplasty into one group for comparison with silicone arthroplasty. A total of 849 articles were screened, yielding 40 studies for final review. The mean postoperative arc of motion and the mean gain in arc of motion of silicone implant with the volar approach were 58 and 17 degrees, respectively, which was greater than surface replacement implant with the dorsal approach at 51 and 8 degrees, respectively. The mean postoperative extension lag of silicone implant with the volar approach and surface replacement with the dorsal approach was 5 and 14 degrees, respectively. The revision rate of silicone implant with the volar approach and surface replacement with the dorsal approach was 6 percent and 18 percent at a mean follow-up of 41.2 and 51 months, respectively. Silicone implant with the volar approach showed the best arc of motion, with less extension lag and fewer complications after surgery among all the implant designs and surgical approaches.

  6. Can physical joint simulators be used to anticipate clinical wear problems of new joint replacement implants prior to market release?

    PubMed

    Medley, John B

    2016-05-01

    One of the most important mandates of physical joint simulators is to provide test results that allow the implant manufacturer to anticipate and perhaps avoid clinical wear problems with their new products. This is best done before market release. This study gives four steps to follow in conducting such wear simulator testing. Two major examples involving hip wear simulators are discussed in which attempts had been made to predict clinical wear performance prior to market release. The second one, involving the DePuy ASR implant systems, is chosen for more extensive treatment by making it an illustrative example to explore whether wear simulator testing can anticipate clinical wear problems. It is concluded that hip wear simulator testing did provide data in the academic literature that indicated some risk of clinical wear problems prior to market release of the ASR implant systems. This supports the idea that physical joint simulators have an important role in the pre-market testing of new joint replacement implants. © IMechE 2016.

  7. Knee joint transplantation combined with surgical angiogenesis in rabbits – a new experimental model

    PubMed Central

    Kremer, Thomas; Giusti, Guilherme; Friedrich, Patricia F.; Willems, Wouter; Bishop, Allen T.; Giessler, Goetz A.

    2012-01-01

    Summary Purpose We have previously described a means to maintain bone allotransplant viability, without long-term immune modulation, replacing allogenic bone vasculature with autogenous vessels. A rabbit model for whole knee joint transplantation was developed and tested using the same methodology, initially as an autotransplant. Materials/Methods Eight New Zealand White rabbit knee joints were elevated on a popliteal vessel pedicle to evaluate limb viability in a non-survival study. Ten additional joints were elevated and replaced orthotopically in a fashion identical to allotransplantation, obviating only microsurgical repairs and immunosuppression. A superficial inferior epigastric facial (SIEF) flap and a saphenous arteriovenous (AV) bundle were introduced into the femur and tibia respectively, generating a neoangiogenic bone circulation. In allogenic transplantation, this step maintains viability after cessation of immunosuppression. Sixteen weeks later, x-rays, microangiography, histology, histomorphometry and biomechanical analysis were performed. Results Limb viability was preserved in the initial 8 animals. Both soft tissue and bone healing occurred in 10 orthotopic transplants. Surgical angiogenesis from the SIEF flap and AV bundle was always present. Bone and joint viability was maintained, with demonstrable new bone formation. Bone strength was less than the opposite side. Arthrosis and joint contractures were frequent. Conclusion We have developed a rabbit knee joint model and evaluation methods suitable for subsequent studies of whole joint allotransplantation. PMID:22113889

  8. Lactobacillus as a rare cause of an infected total knee replacement: a case report

    PubMed Central

    2009-01-01

    Introduction We report a rare case of an infected revision total knee replacement as a result of a Lactobacillus species infection. Lactobacillus infections have been associated with prolonged broad-spectrum antibiotic use. This can have implications in revision surgery, especially when patients have been on previous long-term suppressive antibiotic therapy. Case presentation An 81-year-old British man with a previous history of complex revision knee arthroplasty for infection presented with a hot, swollen knee joint. He had previously been on long-term suppressive antibiotic therapy. Aspiration of the knee joint yielded a culture of Lactobacillus species. Conclusion In patients undergoing revision joint arthroplasty, especially for previous infection, the presence of common and uncommon bacterial species must be excluded and eradicated before further surgical intervention. PMID:19830207

  9. PROUST: Knowledge-Based Program Understanding.

    DTIC Science & Technology

    1983-08-01

    undeniably yes. If anything, PROUST is the minimum that is required! The basis for this conclusion is twofold: 1. In Artificial Intelligence research...Role of Plans in Intellegent Teaching Systems. In Brown, J. S. and Sleeman, D. (editors), Intellegent Tutoring Systems. New York. 1981. [8] Goldstein, I...95, 1978. (12] Rich, C. A Formal Representation for Plans in the Programmer’s Apprentice. In Proc. of the Seventh Int. Joint Conf. on Artificial

  10. Software Architecture for Anti-Submarine Warfare Unmanned Surface Vehicles

    DTIC Science & Technology

    2016-09-01

    discussion about software systems that could be used to control these systems to make the jobs of the human operators easier. B. RESEARCH QUESTIONS... research study. To better understand the role of artificial intelligence in designing autonomous systems, S. Russell and P. Norvig jointly authored a...artificial intelligence, and autonomous systems. This serves as the framework for the real design challenge. 1. Protecting the Battle Group The United

  11. Heat-affected zone and phase composition of 0.09 C-2 Mn-1 Si-Fe steel depending on welding technique

    NASA Astrophysics Data System (ADS)

    Popova, Natalya; Ozhiganov, Eugeniy; Nikonenko, Elena; Ababkov, Nikolay; Smirnov, Aleksander; Koneva, Nina

    2017-11-01

    The paper presents the transmission electron microscopy (TEM) investigations of the structure and phase composition of the heat-affected zone (HAZ) in welded joint modified by four types of welding, namely: electrode welding and electropercussive welding both with and without the introduction of artificial flaws. Artificial flows are aluminum pieces. TEM investigations are carried out within HAZ between the deposited and base metal at 1 mm distance to the latter. The type 0.09C-2Mn-1Si-Fe steel is used as weld material. It is shown that the welding process has an effect on the material morphology, phase composition, faulted structure and its parameters. Long-range stresses are divided into plastic and elastic components. It is demonstrated that the type of welding does not change the structural quality of welded joint represented by perlite and ferrite as contrasted with their volume fraction. According to observations, any type of welding with the introduction of artificial flaws results in the destruction of perlite. Polarization of the dislocation structure occurs. The amplitude of mean internal stresses does not practically depend on the welding type. It is shown that the introduction of artificial flaws both during electrode and electropercussive welding reduce the quantitative parameters of the faulted structure.

  12. Integration of robotics and neuroscience beyond the hand: What kind of synergies?. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by Marco Santello et al.

    NASA Astrophysics Data System (ADS)

    d'Avella, Andrea

    2016-07-01

    Santello et al. [1] review an impressive amount of work on the control of biological and artificial hands that demonstrates how the concept of synergies can lead to a successful integration of robotics and neuroscience. Is it possible to generalize the same approach to the control of biological and artificial limbs and bodies beyond the hand? The human hand synergies that appear most relevant for robotic hands are those defined at the kinematic level, i.e. postural synergies [2]. Postural synergies capture the geometric relations among the many joints of the hand and allow for a low dimensional characterization and synthesis of the static hand postures involved in grasping and manipulating a large set of objects. However, many other complex motor skills such as walking, reaching, throwing, and catching require controlling multi-articular time-varying trajectories rather than static postures. Dynamic control of biological and artificial limbs and bodies, especially when geometric and inertial parameters are uncertain and the joints are compliant, poses great challenges. What kind of synergies might simplify the dynamic control of motor skills involving upper and lower limbs as well as the whole body?

  13. Medicare Program; Cancellation of Advancing Care Coordination Through Episode Payment and Cardiac Rehabilitation Incentive Payment Models; Changes to Comprehensive Care for Joint Replacement Payment Model: Extreme and Uncontrollable Circumstances Policy for the Comprehensive Care for Joint Replacement Payment Model. Final rule; interim final rule with comment period.

    PubMed

    2017-12-01

    This final rule cancels the Episode Payment Models (EPMs) and Cardiac Rehabilitation (CR) Incentive Payment Model and rescinds the regulations governing these models. It also implements certain revisions to the Comprehensive Care for Joint Replacement (CJR) model, including: Giving certain hospitals selected for participation in the CJR model a one-time option to choose whether to continue their participation in the model; technical refinements and clarifications for certain payment, reconciliation and quality provisions; and a change to increase the pool of eligible clinicians that qualify as affiliated practitioners under the Advanced Alternative Payment Model (Advanced APM) track. An interim final rule with comment period is being issued in conjunction with this final rule in order to address the need for a policy to provide some flexibility in the determination of episode costs for providers located in areas impacted by extreme and uncontrollable circumstances.

  14. The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction

    PubMed Central

    Gibon, Emmanuel; Córdova, Luis A.; Lu, Laura; Lin, Tzu-Hua; Yao, Zhenyu; Hamadouche, Moussa; Goodman, Stuart B.

    2017-01-01

    Novel evidence-based prosthetic designs and biomaterials facilitate the performance of highly successful joint replacement (JR) procedures. To achieve this goal, constructs must be durable, biomechanically sound, and avoid adverse local tissue reactions. Different biomaterials such as metals and their alloys, polymers, ceramics, and composites are currently used for JR implants. This review focuses on (1) the biological response to the different biomaterials used for TJR and (2) the chronic inflammatory and foreign-body response induced by byproducts of these biomaterials. A homeostatic state of bone and surrounding soft tissue with current biomaterials for JR can be achieved with mechanically stable, infection free and intact (as opposed to the release of particulate or ionic byproducts) implants. Adverse local tissue reactions (an acute/chronic inflammatory reaction, periprosthetic osteolysis, loosening and subsequent mechanical failure) may evolve when the latter conditions are not met. This article (Part 2 of 2) summarizes the biological response to the non-metallic materials commonly used for joint replacement including polyethylene, ceramics, and polymethylmethacrylate (PMMA), as well as the foreign body reaction to byproducts of these materials. PMID:27080740

  15. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery.

    PubMed

    Halic, Tansel; Kockara, Sinan; Bayrak, Coskun; Rowe, Richard

    2010-10-07

    Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians' training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a process called registration. This issue was overcome by a two-way (virtual object to real domain and real domain to virtual object) semi-automatic registration method. The applicability of the VICON MR setting for the ACDR surgical simulator is demonstrated. The main stream problems encountered in MR surgical simulator development are addressed. First, an effective environment for MR surgical development is constructed. Second, the strain and the stress intensities and critical forces are simulated under the various rasp instrument loadings with impacts that are applied on intervertebral surfaces of the anterior vertebrae throughout the rasping procedure. Third, two approaches are introduced to solve the registration problem in MR setting. Results show that our system creates an effective environment for surgical simulation development and solves tedious and time-consuming registration problems caused by misalignments. Further, the MR ACDR surgery simulator was tested by 5 different physicians who found that the MR simulator is effective enough to teach the anatomical details of cervical discs and to grasp the basics of the ACDR surgery and rasping procedure.

  16. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery

    PubMed Central

    2010-01-01

    Background Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians’ training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. Findings A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a process called registration. This issue was overcome by a two-way (virtual object to real domain and real domain to virtual object) semi-automatic registration method. Conclusions The applicability of the VICON MR setting for the ACDR surgical simulator is demonstrated. The main stream problems encountered in MR surgical simulator development are addressed. First, an effective environment for MR surgical development is constructed. Second, the strain and the stress intensities and critical forces are simulated under the various rasp instrument loadings with impacts that are applied on intervertebral surfaces of the anterior vertebrae throughout the rasping procedure. Third, two approaches are introduced to solve the registration problem in MR setting. Results show that our system creates an effective environment for surgical simulation development and solves tedious and time-consuming registration problems caused by misalignments. Further, the MR ACDR surgery simulator was tested by 5 different physicians who found that the MR simulator is effective enough to teach the anatomical details of cervical discs and to grasp the basics of the ACDR surgery and rasping procedure PMID:20946594

  17. Functionally graded bio-ceramic reinforced PVA hydrogel composites for knee joint artificial cartilages

    NASA Astrophysics Data System (ADS)

    Kumar, G. C. Mohan

    2018-04-01

    Research progress in materials science for bio-based materials for cartilage repair or supportive to host tissue has become a fashionable, worldwide. Few efforts in biomedical engineering has attempted in the development of newer biomaterials successfully. Bio ceramics, a class of materials been used in particulate form as a reinforcement with polymers those ensure its biocompatibility. Every artificial biomedical system has to meet the minimum in Vitro requirements for successful application. Equally the biological behavior of normal and diseased tissues is also essential to understand the artificial systems to human body.

  18. What Pacemakers Can Teach Us about the Ethics of Maintaining Artificial Organs.

    PubMed

    Hutchison, Katrina; Sparrow, Robert

    2016-11-01

    One day soon it may be possible to replace a failing heart, liver, or kidney with a long-lasting mechanical replacement or perhaps even with a 3-D printed version based on the patient's own tissue. Such artificial organs could make transplant waiting lists and immunosuppression a thing of the past. Supposing that this happens, what will the ongoing care of people with these implants involve? In particular, how will the need to maintain the functioning of artificial organs over an extended period affect patients and their doctors and the responsibilities of those who manufacture such devices? Drawing on lessons from the history of the cardiac pacemaker, this article offers an initial survey of the ethical issues posed by the need to maintain and service artificial organs. We briefly outline the nature and history of cardiac pacemakers, with a particular focus on the need for technical support, maintenance, and replacement of these devices. Drawing on the existing medical literature and on our conversations and correspondence with cardiologists, regulators, and manufacturers, we describe five sources of ethical issues associated with pacemaker maintenance: the location of the devices inside the human body, such that maintenance generates surgical risks; the complexity of the devices, which increases the risk of harms to patients as well as introducing potential injustices in access to treatment; the role of software-particularly software that can be remotely accessed-in the functioning of the devices, which generates privacy and security issues; the impact of continual development and improvement of the device; and the influence of commercial interests in the context of a medical device market in which there are several competing products. Finally, we offer some initial suggestions as to how these questions should be answered. © 2016 The Hastings Center.

  19. Scalable training of artificial neural networks with adaptive sparse connectivity inspired by network science.

    PubMed

    Mocanu, Decebal Constantin; Mocanu, Elena; Stone, Peter; Nguyen, Phuong H; Gibescu, Madeleine; Liotta, Antonio

    2018-06-19

    Through the success of deep learning in various domains, artificial neural networks are currently among the most used artificial intelligence methods. Taking inspiration from the network properties of biological neural networks (e.g. sparsity, scale-freeness), we argue that (contrary to general practice) artificial neural networks, too, should not have fully-connected layers. Here we propose sparse evolutionary training of artificial neural networks, an algorithm which evolves an initial sparse topology (Erdős-Rényi random graph) of two consecutive layers of neurons into a scale-free topology, during learning. Our method replaces artificial neural networks fully-connected layers with sparse ones before training, reducing quadratically the number of parameters, with no decrease in accuracy. We demonstrate our claims on restricted Boltzmann machines, multi-layer perceptrons, and convolutional neural networks for unsupervised and supervised learning on 15 datasets. Our approach has the potential to enable artificial neural networks to scale up beyond what is currently possible.

  20. Testing hypotheses and the advancement of science: recent attempts to falsify the equilibrium point hypothesis.

    PubMed

    Feldman, Anatol G; Latash, Mark L

    2005-02-01

    Criticisms of the equilibrium point (EP) hypothesis have recently appeared that are based on misunderstandings of some of its central notions. Starting from such interpretations of the hypothesis, incorrect predictions are made and tested. When the incorrect predictions prove false, the hypothesis is claimed to be falsified. In particular, the hypothesis has been rejected based on the wrong assumptions that it conflicts with empirically defined joint stiffness values or that it is incompatible with violations of equifinality under certain velocity-dependent perturbations. Typically, such attempts use notions describing the control of movements of artificial systems in place of physiologically relevant ones. While appreciating constructive criticisms of the EP hypothesis, we feel that incorrect interpretations have to be clarified by reiterating what the EP hypothesis does and does not predict. We conclude that the recent claims of falsifying the EP hypothesis and the calls for its replacement by EMG-force control hypothesis are unsubstantiated. The EP hypothesis goes far beyond the EMG-force control view. In particular, the former offers a resolution for the famous posture-movement paradox while the latter fails to resolve it.

  1. The Dynamic Multi-objective Multi-vehicle Covering Tour Problem

    DTIC Science & Technology

    2013-06-01

    AI Artificial Intelligence AUV Autonomous Underwater Vehicle CLP Clover Leaf Problem CSP Covering Salesman Problem CTP Covering Tour Problem CVRP...introduces a new formalization - the DMOMCTP. Related works from routing problems, Artificial Intelligence ( AI ), and MOPs are discussed briefly. As a...the rest of that framework being replaced. The codebase differs from jMetal 4.2 in that it can handle the time and DM dependent nature of the DMOMCTP

  2. Update on Renal Replacement Therapy: Implantable Artificial Devices and Bioengineered Organs.

    PubMed

    Attanasio, Chiara; Latancia, Marcela T; Otterbein, Leo E; Netti, Paolo A

    2016-08-01

    Recent advances in the fields of artificial organs and regenerative medicine are now joining forces in the areas of organ transplantation and bioengineering to solve continued challenges for patients with end-stage renal disease. The waiting lists for those needing a transplant continue to exceed demand. Dialysis, while effective, brings different challenges, including quality of life and susceptibility to infection. Unfortunately, the majority of research outputs are far from delivering satisfactory solutions. Current efforts are focused on providing a self-standing device able to recapitulate kidney function. In this review, we focus on two remarkable innovations that may offer significant clinical impact in the field of renal replacement therapy: the implantable artificial renal assist device (RAD) and the transplantable bioengineered kidney. The artificial RAD strategy utilizes micromachining techniques to fabricate a biohybrid system able to mimic renal morphology and function. The current trend in kidney bioengineering exploits the structure of the native organ to produce a kidney that is ready to be transplanted. Although these two systems stem from different technological approaches, they are both designed to be implantable, long lasting, and free standing to allow patients with kidney failure to be autonomous. However, for both of them, there are relevant issues that must be addressed before translation into clinical use and these are discussed in this review.

  3. Surrogate modeling of deformable joint contact using artificial neural networks.

    PubMed

    Eskinazi, Ilan; Fregly, Benjamin J

    2015-09-01

    Deformable joint contact models can be used to estimate loading conditions for cartilage-cartilage, implant-implant, human-orthotic, and foot-ground interactions. However, contact evaluations are often so expensive computationally that they can be prohibitive for simulations or optimizations requiring thousands or even millions of contact evaluations. To overcome this limitation, we developed a novel surrogate contact modeling method based on artificial neural networks (ANNs). The method uses special sampling techniques to gather input-output data points from an original (slow) contact model in multiple domains of input space, where each domain represents a different physical situation likely to be encountered. For each contact force and torque output by the original contact model, a multi-layer feed-forward ANN is defined, trained, and incorporated into a surrogate contact model. As an evaluation problem, we created an ANN-based surrogate contact model of an artificial tibiofemoral joint using over 75,000 evaluations of a fine-grid elastic foundation (EF) contact model. The surrogate contact model computed contact forces and torques about 1000 times faster than a less accurate coarse grid EF contact model. Furthermore, the surrogate contact model was seven times more accurate than the coarse grid EF contact model within the input domain of a walking motion. For larger input domains, the surrogate contact model showed the expected trend of increasing error with increasing domain size. In addition, the surrogate contact model was able to identify out-of-contact situations with high accuracy. Computational contact models created using our proposed ANN approach may remove an important computational bottleneck from musculoskeletal simulations or optimizations incorporating deformable joint contact models. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Surrogate Modeling of Deformable Joint Contact using Artificial Neural Networks

    PubMed Central

    Eskinazi, Ilan; Fregly, Benjamin J.

    2016-01-01

    Deformable joint contact models can be used to estimate loading conditions for cartilage-cartilage, implant-implant, human-orthotic, and foot-ground interactions. However, contact evaluations are often so expensive computationally that they can be prohibitive for simulations or optimizations requiring thousands or even millions of contact evaluations. To overcome this limitation, we developed a novel surrogate contact modeling method based on artificial neural networks (ANNs). The method uses special sampling techniques to gather input-output data points from an original (slow) contact model in multiple domains of input space, where each domain represents a different physical situation likely to be encountered. For each contact force and torque output by the original contact model, a multi-layer feed-forward ANN is defined, trained, and incorporated into a surrogate contact model. As an evaluation problem, we created an ANN-based surrogate contact model of an artificial tibiofemoral joint using over 75,000 evaluations of a fine-grid elastic foundation (EF) contact model. The surrogate contact model computed contact forces and torques about 1000 times faster than a less accurate coarse grid EF contact model. Furthermore, the surrogate contact model was seven times more accurate than the coarse grid EF contact model within the input domain of a walking motion. For larger input domains, the surrogate contact model showed the expected trend of increasing error with increasing domain size. In addition, the surrogate contact model was able to identify out-of-contact situations with high accuracy. Computational contact models created using our proposed ANN approach may remove an important computational bottleneck from musculoskeletal simulations or optimizations incorporating deformable joint contact models. PMID:26220591

  5. Artificial Muscle Kits for the Classroom

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Commonly referred to as "artificial muscles," electroactive polymer (EAP) materials are lightweight strips of highly flexible plastic that bend or stretch when subjected to electric voltage. EAP materials may prove to be a substitution for conventional actuation components such as motors and gears. Since the materials behave similarly to biological muscles, this emerging technology has the potential to develop improved prosthetics and biologically-inspired robots, and may even one day replace damaged human muscles. The practical application of artificial muscles provides a challenge, however, since the material requires improved effectiveness and durability before it can fulfill its potential.

  6. Regenerative Medicine and Restoration of Joint Function

    DTIC Science & Technology

    2014-12-01

    to resist fracture and excessive deformation under antici- pated mechanical loading conditions both during the early healing process and for longer...per sample type), the results sug- gest a correlation between percent fractured sinter neck area and mechanical properties with the lowest bending...joint replacement are used to treat a joint with an intra-articular fracture or destroyed by a combat injury. Generation of personalized, anatomically

  7. Low cracking concretes for the closure pours and overlays of the Dunlap Creek Bridge : final report.

    DOT National Transportation Integrated Search

    2017-10-01

    Joints, wide cracks, and poor-quality concretes facilitate the intrusion of chlorides, causing corrosion in bridge decks and substructures. In this study, joints were replaced with closure pours (link slabs) consisting of low permeability fiber-reinf...

  8. Development of an Underactuated 2-DOF Wrist Joint using McKibben PAMs

    NASA Astrophysics Data System (ADS)

    Rajagopal, S. P.; Jain, S.; Ramasubramanian, S. N.; Johnson, B. V.; Dwivedy, S. K.

    2014-10-01

    In this work, model of an underactuated 2-DOF wrist joint with pneumatically actuated muscles is proposed. For the joint, McKibben-type artificial muscles are used in parallel configuration for the actuation. For each Degree of Freedom (DOF) one agonist-antagonist pair arrangement is usually used with a pulley mechanism. A mathematical model of wrist joint is derived using conventional forward kinematic analysis. The static model relating pressure in the muscle with the orientation of the wrist joint is obtained by combining the experimental data and mathematical model. Regulation of pressure can be achieved by pulse width modulation control of on/off solenoid valves. A set of free vibration experiments are done for the dynamic identification of the muscle characteristics.

  9. 42 CFR 414.202 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... or contact lenses furnished subsequent to each cataract surgery with insertion of an intraocular lens; and (3) Leg, arm, back, and neck braces, and artificial legs, arms, and eyes, including replacements...

  10. Dose-dependent cytotoxicity evaluation of graphite nanoparticles for diamond-like carbon film application on artificial joints.

    PubMed

    Liao, T T; Deng, Q Y; Wu, B J; Li, S S; Li, X; Wu, J; Leng, Y X; Guo, Y B; Huang, N

    2017-01-24

    While a diamond-like carbon (DLC)-coated joint prosthesis represents the implant of choice for total hip replacement in patients, it also leads to concern due to the cytotoxicity of wear debris in the form of graphite nanoparticles (GNs), ultimately limiting its clinical use. In this study, the cytotoxicity of various GN doses was evaluated. Mouse macrophages and osteoblasts were incubated with GNs (<30 nm diameter), followed by evaluation of cytotoxicity by means of assessing inflammatory cytokines, results of alkaline phosphatase assays, and related signaling protein expression. Cytotoxicity evaluation showed that cell viability decreased in a dose-dependent manner (10-100 μg ml -1 ), and steeply declined at GNs concentrations greater than 30 μg ml -1 . Noticeable cytotoxicity was observed as the GN dose exceeded this threshold due to upregulated receptor of activator of nuclear factor kB-ligand expression and downregulated osteoprotegerin expression. Meanwhile, activated macrophage morphology was observed as a result of the intense inflammatory response caused by the high doses of GNs (>30 μg ml -1 ), as observed by the increased release of TNF-α and IL-6. The results suggest that GNs had a significant dose-dependent cytotoxicity in vitro, with a lethal dose of 30 μg ml -1 leading to dramatic increases in cytotoxicity. Our GN cytotoxicity evaluation indicates a safe level for wear debris-related arthropathy and could propel the clinical application of DLC-coated total hip prostheses.

  11. Novel Highly Porous Metal Technology in Artificial Hip and Knee Replacement: Processing Methodologies and Clinical Applications

    NASA Astrophysics Data System (ADS)

    Muth, John; Poggie, Matthew; Kulesha, Gene; Michael Meneghini, R.

    2013-02-01

    Hip and knee replacement can dramatically improve a patient's quality of life through pain relief and restored function. Fixation of hip and knee replacement implants to bone is critical to the success of the procedure. A variety of roughened surfaces and three-dimensional porous surfaces have been used to enhance biological fixation on orthopedic implants. Recently, highly porous metals have emerged as versatile biomaterials that may enhance fixation to bone and are suitable to a number of applications in hip and knee replacement surgery. This article provides an overview of several processes used to create these implant surfaces.

  12. Laboratory studies on the tribology of hard bearing hip prostheses: ceramic on ceramic and metal on metal.

    PubMed

    Vassiliou, K; Scholes, S C; Unsworth, A

    2007-01-01

    Total hip replacements offer relief to a great many patients every year around the world. With an expected service life of around 25 years on most devices, and with younger and younger patients undergoing this surgery, it is of great importance to understand the mechanisms of their function. Tribological testing of both conventional and hard bearing joint combinations have been conducted in many centres throughout the world, and, after being initially abandoned owing to premature failures, hard bearing combinations have been revisited as viable options for joint replacements. Improved design, manufacturing procedures, and material compositions have led to improved performance over first-generation designs in both metal-on-metal and ceramic-on-ceramic hip prostheses. This paper offers a review of the work conducted in an attempt to highlight the most important factors affecting joint performance and tribology of hard bearing combinations. The tribological performance of these joints is superior to that of conventional metal- or ceramic-on-polymer designs.

  13. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    PubMed Central

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329

  14. Fluid mechanics of artificial heart valves.

    PubMed

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-02-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

  15. Technical vision for robots

    NASA Astrophysics Data System (ADS)

    1985-01-01

    A new invention by scientists who have copied the structure of a human eye will help replace a human telescope-watching astronomer with a robot. It will be possible to provide technical vision not only for robot astronomers but also for their industrial fellow robots. So far, an artificial eye with dimensions close to those of a human eye discerns only black-and-white images. But already the second model of the eye is to perceive colors as well. Polymers which are suited for the role of the coat of an eye, lens, and vitreous body were applied. The retina has been replaced with a bundle of the finest glass filaments through which light rays get onto photomultipliers. They can be positioned outside the artificial eye. The main thing is to prevent great losses in the light guide.

  16. Effect of leisure time physical activity on severe knee or hip osteoarthritis leading to total joint replacement: a population-based prospective cohort study

    PubMed Central

    2012-01-01

    Background Studies on leisure time physical activity as risk factor or protective factor for knee or hip osteoarthritis (OA) show divergent results. Longitudinal prospective studies are needed to clarify the association of physical activity with future OA. The aim was to explore in a prospective population-based cohort study the influence of leisure time physical activity on severe knee or hip OA, defined as knee or hip replacement due to OA. Methods Leisure time physical activity was reported by 28320 participants (mean age 58 years (SD 7.6), 60% women) at baseline. An overall leisure time physical activity score, taking both duration and intensity of physical activities into account, was created. The most commonly reported activities were also used for analysis. The incidence of knee or hip replacement due to OA over 11 years was monitored by linkage with the Swedish hospital discharge register. Cox’s proportional hazards model (crude and adjusted for potential confounding factors) was used to assess the incidence of total joint replacement, or osteotomy (knee), in separate analyses of leisure time physical activity. Results There was no significant overall association between leisure time physical activity and risk for knee or hip replacement due to OA over the 11-year observation time. For women only, the adjusted RR (95% CI) for hip replacement was 0.66 (0.48, 0.89) (fourth vs. first quartile), indicating a lower risk of hip replacement in those with the highest compared with the lowest physical activity. The most commonly reported activities were walking, bicycling, using stairs, and gardening. Walking was associated with a lower risk of hip replacement (adjusted RR 0.76 (95% CI 0.61, 0.94), specifically for women (adjusted RR 0.75 (95% CI 0.57, 0.98)). Conclusions In this population-based study of middle-aged men and women, leisure time physical activity showed no consistent overall relationship with incidence of severe knee or hip OA, defined as joint replacement due to OA, over 11 years. For women, higher leisure time physical activity may have a protective role for the incidence of hip replacement. Walking may have a protective role for hip replacement, specifically for women. PMID:22595023

  17. Artificial chordae for degenerative mitral valve disease: critical analysis of current techniques

    PubMed Central

    Ibrahim, Michael; Rao, Christopher; Athanasiou, Thanos

    2012-01-01

    The surgical repair of degenerative mitral valve disease involves a number of technical points of importance. The use of artificial chordae for the repair of degenerative disease has increased as a part of the move from mitral valve replacement to repair of the mitral valve. The use of artificial chordae provides an alternative to the techniques pioneered by Carpentier (including the quadrangular resection, transfer of native chordae and papillary muscle shortening/plasty), which can be more technically difficult. Despite a growth in their uptake and the indications for their use, a number of challenges remain for the use of artificial chordae in mitral valve repair, particularly in the determination of the correct length to ensure optimal leaflet coaptation. Here, we analyse over 40 techniques described for artificial chordae mitral valve repair in the setting of degenerative disease. PMID:22962321

  18. [Consequence of European Directive 2004/23/EC for bone banks in Germany].

    PubMed

    Pruss, A; Knaepler, H; Katthagen, B-D; Frommelt, L

    2005-11-01

    Allogenic bone grafting is an established method in revision surgery of artificial joint replacement and spinal surgery in case of bone defects. In Germany, femoral heads from living donors undergoing total hip replacement are frequently used. These grafts are processed according to the "Guidelines for the management of bone banking" issued by the Federal Medical Board. Bone grafts are drugs according to German law. Local bone banks are excluded from the regulations of the federal law on drugs [Arzneimittelgesetz (AMG) section sign 4a (4)] if certain requirements are fulfilled. The Directive 2004/23/EC of the European Parliament and of The Council on Setting Standards of Quality and Safety for the Donation, Procurement, Testing, Processing, Preservation, Storage and Distribution of Human Tissues and Cells has to be implemented into national law within 2 years. The exception of section sign 4a (4) will no longer be possible. Thus a legal construction has to be found which allows running local bone banks in compliance with the new legal settings. Three conditions will be possible: (1) a single physician procures a graft for another patient of his, (2) grafts are procured in one hospital and are used exclusively in this hospital: a license from the local authorities and a strict quality assessment according to GMP-rules is required, (3) if the grafts are distributed to other hospitals, a license from the local authorities and registration as a drug by the federal authorities are necessary.

  19. Determination of the Corrosive Conditions Present within Aircraft Lap-Splice Joints

    NASA Technical Reports Server (NTRS)

    Lewis, Karen S.; Kelly, Robert G.; Piascik, Robert S.

    1999-01-01

    The complexity of airframe structure lends itself to damage resulting from crevice corrosion. Fuselage lap-splice joints are a particularly important structural detail in this regard because of the difficulty associated with detection and measurement of corrosion in these occluded regions. The objective of this work is to develop a laboratory corrosion test protocol to identify the chemistry to which lap joints are exposed and to develop a model of the corrosion within the joints. A protocol for collecting and identifying the chemistry of airframe crevice corrosion has been developed. Capillary electrophoresis (CE) is used to identify the ionic species contained in corrosion product samples removed from fuselage lap splice joints. CE analysis has been performed on over sixty corrosion product samples removed from both civilian and military aircraft. Over twenty different ions have been detected. Measurements of pH of wetted corroded surfaces indicated an alkaline occluded solution. After determining the species present and their relative concentrations, the resultant solution was reproduced in bulk and electrochemical tests were performed to determine the corrosion rate. Electrochemical analyses of the behavior of AA2024-T3 in these solutions gave corrosion rates of up to 250 microns per year (10 mpy). Additional tests have determined the relative importance of each of the detected ions in model solutions used for future predictive tests. The statistically significant ions have been used to create a second generation solution. Laboratory studies have also included exposure tests involving artificial lap joints exposed to various simulated bulk and crevice environments. The extent and morphology of the attack in artificial lap joints has been compared to studies of corroded samples from actual aircraft. Other effects, such as temperature and potential, as well as the impact of the environment on fatigue crack growth have also been studied.

  20. Rebooting Computers as Learning Machines

    DOE PAGES

    DeBenedictis, Erik P.

    2016-06-13

    Artificial neural networks could become the technological driver that replaces Moore's law, boosting computers' utlity through a process akin to automatic programming--although physics and computer architecture would are also a factor.

  1. Childhood Cancer: Osteosarcoma

    MedlinePlus

    ... either a bone graft (usually from a bone bank) or more often a special metal prosthesis (artificial ... risk of infection and fracture is higher with bank bone replacement and therefore metal prostheses are more ...

  2. Rebooting Computers as Learning Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeBenedictis, Erik P.

    Artificial neural networks could become the technological driver that replaces Moore's law, boosting computers' utlity through a process akin to automatic programming--although physics and computer architecture would are also a factor.

  3. Tribochemical Characterization and Tribocorrosive Behavior of CoCrMo Alloys: A Review

    PubMed Central

    Toh, Wei Quan; Liu, Erjia; Tor, Shu Beng

    2017-01-01

    Orthopedic implants first started out as an all-metal hip joint replacement. However, poor design and machinability as well as unsatisfactory surface finish subjected the all-metal joint replacement to being superseded by a polyethylene bearing. Continued improvement in manufacturing techniques together with the reality that polyethylene wear debris can cause hazardous reactions in the human body has brought about the revival of metal-on-metal (MOM) hip joints in recent years. This has also led to a relatively new research area that links tribology and corrosion together. This article aims at reviewing the commonly used tribochemical methods adopted in the analysis of tribocorrosion and putting forward some of the models and environmental factors affecting the tribocorrosive behavior of CoCrMo alloys, a widely-used class of biomaterial for orthopedic implants. PMID:29278375

  4. The trivector approach for minimally invasive total knee arthroplasty: a technical note.

    PubMed

    Benazzo, Francesco; Rossi, Stefano Marco Paolo

    2012-09-01

    One of the main criticisms of minimally invasive approaches in total knee arthroplasty has been their poor adaptability in cases of major deformity or stiffness of the knee joint. When they are used in such cases, excessive soft-tissue tension is needed to provide appropriate joint exposure. Here, we describe the "mini trivector approach," which has become our standard approach for total knee replacement because it permits us to enlarge the indication for minimally or less invasive total knee replacement to many knees where quad sparing, a subvastus approach, or a mini quad or mini midvastus snip may not be sufficient to achieve correct exposure. It consists of a limited double snip of the VMO and the quadriceps tendon that reduces tension on the extensor mechanism and allows easier verticalization of the patella as well as good joint exposure.

  5. Tribochemical Characterization and Tribocorrosive Behavior of CoCrMo Alloys: A Review.

    PubMed

    Toh, Wei Quan; Tan, Xipeng; Bhowmik, Ayan; Liu, Erjia; Tor, Shu Beng

    2017-12-26

    Orthopedic implants first started out as an all-metal hip joint replacement. However, poor design and machinability as well as unsatisfactory surface finish subjected the all-metal joint replacement to being superseded by a polyethylene bearing. Continued improvement in manufacturing techniques together with the reality that polyethylene wear debris can cause hazardous reactions in the human body has brought about the revival of metal-on-metal (MOM) hip joints in recent years. This has also led to a relatively new research area that links tribology and corrosion together. This article aims at reviewing the commonly used tribochemical methods adopted in the analysis of tribocorrosion and putting forward some of the models and environmental factors affecting the tribocorrosive behavior of CoCrMo alloys, a widely-used class of biomaterial for orthopedic implants.

  6. Late Streptococcus bovis infection of total knee replacement complicated by infective endocarditis and associated with colonic ulcers

    PubMed Central

    Nagy, Mathias Thomas; Hla, Sann Minn; Keys, Graham Watson

    2013-01-01

    Streptococcus bovis is rare cause of late infections after total knee replacement (TKR). This report presents a case of confirmed late septic arthritis following TKR caused by S bovis that was further complicated with infective endocarditis resulting in aortic valve insufficiency in an immunecompetent patient. As an association between S bovis and gastrointestinal malignancies is suggested, a workup for such malignancies was performed that revealed non-malignant ulcers in patient's ascending colon. The patient is currently recovering from his aortic valve replacement surgery and is scheduled to have annual colonoscopies. His knee joint has improved; however, he developed constant pain because of underlying chronic infection in the affected joint and has difficulties mobilising. Therefore, a revision TKR is considered but postponed until he fully recovers from his heart valve surgery. PMID:23744853

  7. Trapezium Bone Density-A Comparison of Measurements by DXA and CT.

    PubMed

    Breddam Mosegaard, Sebastian; Breddam Mosegaard, Kamille; Bouteldja, Nadia; Bæk Hansen, Torben; Stilling, Maiken

    2018-01-18

    Bone density may influence the primary fixation of cementless implants, and poor bone density may increase the risk of implant failure. Before deciding on using total joint replacement as treatment in osteoarthritis of the trapeziometacarpal joint, it is valuable to determine the trapezium bone density. The aim of this study was to: (1) determine the correlation between measurements of bone mineral density of the trapezium obtained by dual-energy X-ray absorptiometry (DXA) scans by a circumference method and a new inner-ellipse method; and (2) to compare those to measurements of bone density obtained by computerized tomography (CT)-scans in Hounsfield units (HU). We included 71 hands from 59 patients with a mean age of 59 years (43-77). All patients had Eaton-Glickel stage II-IV trapeziometacarpal (TM) joint osteoarthritis, were under evaluation for trapeziometacarpal total joint replacement, and underwent DXA and CT wrist scans. There was an excellent correlation (r = 0.94) between DXA bone mineral density measures using the circumference and the inner-ellipse method. There was a moderate correlation between bone density measures obtained by DXA- and CT-scans with (r = 0.49) for the circumference method, and (r = 0.55) for the inner-ellipse method. DXA may be used in pre-operative evaluation of the trapezium bone quality, and the simpler DXA inner-ellipse measurement method can replace the DXA circumference method in estimation of bone density of the trapezium.

  8. Prediction of the Vickers Microhardness and Ultimate Tensile Strength of AA5754 H111 Friction Stir Welding Butt Joints Using Artificial Neural Network

    PubMed Central

    De Filippis, Luigi Alberto Ciro; Serio, Livia Maria; Facchini, Francesco; Mummolo, Giovanni; Ludovico, Antonio Domenico

    2016-01-01

    A simulation model was developed for the monitoring, controlling and optimization of the Friction Stir Welding (FSW) process. This approach, using the FSW technique, allows identifying the correlation between the process parameters (input variable) and the mechanical properties (output responses) of the welded AA5754 H111 aluminum plates. The optimization of technological parameters is a basic requirement for increasing the seam quality, since it promotes a stable and defect-free process. Both the tool rotation and the travel speed, the position of the samples extracted from the weld bead and the thermal data, detected with thermographic techniques for on-line control of the joints, were varied to build the experimental plans. The quality of joints was evaluated through destructive and non-destructive tests (visual tests, macro graphic analysis, tensile tests, indentation Vickers hardness tests and t thermographic controls). The simulation model was based on the adoption of the Artificial Neural Networks (ANNs) characterized by back-propagation learning algorithm with different types of architecture, which were able to predict with good reliability the FSW process parameters for the welding of the AA5754 H111 aluminum plates in Butt-Joint configuration. PMID:28774035

  9. Quick bacteriophage-mediated bioluminescence assay for detecting Staphylococcus spp. in sonicate fluid of orthopaedic artificial joints.

    PubMed

    Šuster, Katja; Podgornik, Aleš; Cör, Andrej

    2017-07-01

    Staphylococcus spp. accounts for up to two thirds of all microorganisms causing prosthetic joint infections, with Staphylococcus aureus and Staphylococcus epidermidis being the major cause. The present study describes a diagnostic model to detect staphylococci using a specific bacteriophage and bioluminescence detection, exploring the possibility of its use on sonicate fluid of orthopaedic artificial joints. Intracellular adenosine-5'-triphosphate release by bacteriophage mediated lysis of staphylococci was assessed to determine optimal parameters for detection. With the optimized method, a limit of detection of around 103 CFU/mL was obtained after incubation with bacteriophage for 2 h. Importantly, sonicate fluid did not prevent the ability of bacteriophage to infect bacteria and all simulated infected sonicate fluid as well as 6 clinical samples with microbiologically proven staphylococcal infection were detected as positive. The total assay took approximately 4 h. Collectively, the results indicate that the developed method promises a rapid, inexpensive and specific diagnostic detection of staphylococci in sonicate fluid of infected prosthetic joints. In addition, the unlimited pool of different existing bacteriophages, with different specificity for all kind of bacteria gives the opportunity for further investigations, improvements of the current model and implementation in other medical fields for the purpose of the establishment of a rapid diagnosis.

  10. Berkeley Lab Site Map

    Science.gov Websites

    , Emeryville, CA Joint Center for Artificial Photosynthesis (JCAP) - Bldg. 976, 2929 7th St., Suite 105 Financial Officer (OCFO) - Bldg. 971, 6401 Hollis St., Emeryville CA Life Sciences Division @ Potter St

  11. Artificial Disc Replacement

    MedlinePlus

    ... Cervical Foraminotomy Spinal Fusion Nonsurgical Treatments Activity Modification Chiropractic – A Conversation with Dr. Jordan Gliedt, DC Directional ... with non-operative care such as medication, injections, chiropractic care and/or physical therapy. Typically, you will ...

  12. Replacing a Missing Tooth

    MedlinePlus

    ... usually shifted, so this must be corrected. A space is often opened up and maintained for later ... with an artificial tooth serves to maintain the space and improve speech and appearance until a definitive ...

  13. Getting a New Heart

    MedlinePlus

    ... may be able to replace it with an artificial (man-made) valve. Cardiac size reduction . During this procedure, your doctor removes a piece of the heart muscle from an enlarged heart. This makes your ...

  14. Patterns of Ninety-Day Readmissions Following Total Joint Replacement in a Bundled Payment Initiative.

    PubMed

    Behery, Omar A; Kester, Benjamin S; Williams, Jarrett; Bosco, Joseph A; Slover, James D; Iorio, Richard; Schwarzkopf, Ran

    2017-04-01

    Alternative payment models aim to improve quality and decrease costs associated with total joint replacement. Postoperative readmissions within 90 days are of interest to clinicians and administrators as there is no additional reimbursement beyond the episode bundled payment target price. The aim of this study is to improve the understanding of the patterns of readmission which would better guide perioperative patient management affecting readmissions. We hypothesize that readmissions have different timing, location, and patient health profile patterns based on whether the readmission is related to a medical or surgical diagnosis. A retrospective cohort of 80 readmissions out of 1412 total joint replacement patients reimbursed through a bundled payment plan was analyzed. Patients were grouped by readmission diagnosis (surgical or medical) and the main variables analyzed were time to readmission, location of readmission, and baseline Perioperative Orthopaedic Surgical Home and American Society of Anesthesiologists scores capturing pre-existing state of health. Nonparametric tests and multivariable regressions were used to test associations. Surgical readmissions occurred earlier than medical readmissions (mean 18 vs 33 days, P = .011), and were more likely to occur at the hospital where the surgery was performed (P = .035). Perioperative Orthopaedic Surgical Home and American Society of Anesthesiologists scores did not predict medical vs surgical readmissions (P = .466 and .879) after adjusting for confounding variables. Readmissions appear to follow different patterns depending on whether they are surgical or medical. Surgical readmissions occur earlier than medical readmissions, and more often at the hospital where the surgery was performed. The results of this study suggest that these 2 types of readmissions have different patterns with different implications toward perioperative care and follow-up after total joint replacement. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Exploring the relationships between International Classification of Functioning, Disability and Health (ICF) constructs of Impairment, Activity Limitation and Participation Restriction in people with osteoarthritis prior to joint replacement.

    PubMed

    Pollard, Beth; Johnston, Marie; Dieppe, Paul

    2011-05-16

    The International Classification of Functioning, Disability and Health (ICF) proposes three main constructs, impairment (I), activity limitation (A) and participation restriction (P). The ICF model allows for all paths between the constructs to be explored, with significant paths likely to vary for different conditions. The relationships between I, A and P have been explored in some conditions but not previously in people with osteoarthritis prior to joint replacement. The aim of this paper is to examine these relationships using separate measures of each construct and structural equation modelling. A geographical cohort of 413 patients with osteoarthritis about to undergo hip and knee joint replacement completed the Aberdeen measures of Impairment, Activity Limitation and Participation Restriction (Ab-IAP). Confirmatory factor analysis was used to test the three factor (I, A, P) measurement model. Structural equation modelling was used to explore the I, A and P pathways in the ICF model. There was support from confirmatory factor analysis for the three factor I, A, P measurement model. The structural equation model had good fit [S-B Chi-square = 439.45, df = 149, CFI robust = 0.91, RMSEA robust = 0.07] and indicated significant pathways between I and A (standardised coefficient = 0.76 p < 0.0001) and between A and P (standardised coefficient = 0.75 p < 0.0001). However, the path between I and P was not significant (standardised coefficient = 0.01). The significant pathways suggest that treatments and interventions aimed at reducing impairment, such as joint replacement, may only affect P indirectly, through A, however, longitudinal data would be needed to establish this.

  16. Modeling the Potential Economic Impact of the Medicare Comprehensive Care for Joint Replacement Episode-Based Payment Model.

    PubMed

    Maniya, Omar Z; Mather, Richard C; Attarian, David E; Mistry, Bipin; Chopra, Aneesh; Strickland, Matt; Schulman, Kevin A

    2017-11-01

    The Medicare program has initiated Comprehensive Care for Joint Replacement (CJR), a bundled payment mandate for lower extremity joint replacements. We sought to determine the degree to which hospitals will invest in care redesign in response to CJR, and to project its economic impacts. We defined 4 potential hospital management strategies to address CJR: no action, light care management, heavy care management, and heavy care management with contracting. For each of 798 hospitals included in CJR, we used hospital-specific volume, cost, and quality data to determine the hospital's economically dominant strategy. We aggregated data to assess the percentage of hospitals pursuing each strategy; savings to the health care system; and costs and percentages of CJR-derived revenues gained or lost for Medicare, hospitals, and postacute care facilities. In the model, 83.1% of hospitals (range 55.0%-100.0%) were expected to take no action in response to CJR, and 16.1% of hospitals (range 0.0%-45.0%) were expected to pursue heavy care management with contracting. Overall, CJR is projected to reduce health care expenditures by 0.5% (range 0.0%-4.1%) or $14 million (range $0-$119 million). Medicare is expected to save 2.2% (range 2.2%-2.2%), hospitals are projected to lose 3.7% (range 4.7% loss to 3.8% gain), and postacute care facilities are expected to lose 6.5% (range 0.0%-12.8%). Hospital administrative costs are projected to increase by $63 million (range $0-$148 million). CJR is projected to have a negligible impact on total health care expenditures for lower extremity joint replacements. Further research will be required to assess the actual care management strategies adopted by CJR hospitals. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Comparison of a self-administered foot evaluation questionnaire (SAFE-Q) between joint-preserving arthroplasty and resection-replacement arthroplasty in forefoot surgery for patients with rheumatoid arthritis.

    PubMed

    Ebina, Kosuke; Hirao, Makoto; Hashimoto, Jun; Nampei, Akihide; Shi, Kenrin; Tomita, Tetsuya; Futai, Kazuma; Kunugiza, Yasuo; Noguchi, Takaaki; Yoshikawa, Hideki

    2017-09-01

    To clarify the difference of patient-based outcome between joint-preserving arthroplasty and resection-replacement arthroplasty in forefoot surgery for patients with rheumatoid arthritis (RA). A total of 63 feet of 49 RA patients who underwent forefoot surgery were asked to answer pre-operative and post-operative self-administered foot evaluation questionnaire (SAFE-Q). Patients were treated with either (1) metatarsal head resection-replacement arthroplasty (28 feet, post-operative mean age 63.8 years, follow-up 4.2 years, DAS28-CRP 2.2) or (2) metatarsophalangeal joint-preserving arthroplasty (35 feet, post-operative mean age 63.1 years, follow-up 3.6 years, DAS28-CRP 2.1) at each surgeon's discretion. Mean pre-operative and post-operative subscale scores of SAFE-Q of group (1) and (2) were as follows. Pain and pain-related [(1) pre-op 36.8 to post-op 75.0 vs. (2) pre-op 42.2 to post-op 82.6], physical functioning and daily-living [(1) 43.2-68.8 vs. (2) 52.778.1], social functioning [(1) 44.3-72.0 vs. (2) 52.5-81.9], general health and well-being [(1) 48.4-68.4 vs. (2) 45.5-84.4], and shoe-related [(1) 30.1-50.3 vs. (2) 30.6-64.4]. Both general health and well-being subscale scores (p < 0.05) and shoe-related subscale scores (p < 0.05) were significantly more improved in group (2) compared with group (1). Joint-preserving arthroplasty resulted in better patient-based outcomes than resection-replacement arthroplasty.

  18. RSA and registries: the quest for phased introduction of new implants.

    PubMed

    Nelissen, Rob G H H; Pijls, Bart G; Kärrholm, Johan; Malchau, Henrik; Nieuwenhuijse, Marc J; Valstar, Edward R

    2011-12-21

    Although the overall survival of knee and hip prostheses at ten years averages 90%, recent problems with several hip and knee prostheses have illustrated that the orthopaedic community, industry, and regulators can still further improve patient safety. Given the early predictive properties of roentgen stereophotogrammetric analysis (RSA) and the meticulous follow-up of national joint registries, these two methods are ideal tools for such a phased clinical introduction. In this paper, we elaborate on the predictive power of RSA within a two-year follow-up after arthroplasty and its relationship to national joint registries. The association between RSA prosthesis-migration data and registry data is evaluated. The five-year rate of revision of RSA-tested total knee replacements was compared with that of non-RSA-tested total knee replacements. Data were extracted from the published results of the national joint registries of Sweden, Australia, and New Zealand. There was a 22% to 35% reduction in the number of revisions of RSA-tested total knee replacements as compared with non-RSA-tested total knee replacements in the national joint registries. Assuming that the total cost of total knee arthroplasty is $37,000 in the United States, a 22% to 35% reduction in the number of revisions (currently close to 55,000 annually) could lead to an estimated annual savings of over $400 million to the health-care system. The phased clinical introduction of new prostheses with two-year RSA results as a qualitative tool could lead to better patient care and could reduce the costs associated with revision total knee arthroplasty. Follow-up in registries is necessary to substantiate these results and to improve post-market surveillance.

  19. Defense Acquisitions: Assessments of Selected Weapon Programs

    DTIC Science & Technology

    2016-03-01

    Increment 3 81 Indirect Fire Protection Capability Increment 2-Intercept Block 1 (IFPC Inc 2-I Block 1) 83 Improved Turbine Engine Program (ITEP...ITEP Improved Turbine Engine Program JAGM Joint Air-to-Ground Missile JLTV Joint Light Tactical Vehicle JSTARS Recap Joint Surveillance Target...Attack Radar System Recap 09/2017 —-   Improved Turbine Engine Program 06/2018 O O O Amphibious Ship Replacement 09/2018 O O Advanced Pilot

  20. Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems

    PubMed Central

    Kuo, Chien-Wei

    2017-01-01

    Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system. PMID:29230411

  1. Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems.

    PubMed

    Su, Chen-Ying; Kuo, Chien-Wei; Fang, Hsu-Wei

    2017-01-01

    Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system.

  2. Second-site prosthetic joint infection in patients with multiple prosthetic joints.

    PubMed

    Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G

    2018-04-10

    Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.

  3. Artificial Organs 2016: A Year in Review.

    PubMed

    Hadsell, Angela T; Malchesky, Paul S

    2017-03-01

    In this Editor's Review, articles published in 2016 are organized by category and briefly summarized. We aim to provide a brief reflection of the currently available worldwide knowledge that is intended to advance and better human life while providing insight for continued application of technologies and methods of organ Replacement, Recovery, and Regeneration. As the official journal of The International Federation for Artificial Organs, The International Faculty for Artificial Organs, the International Society for Mechanical Circulatory Support, the International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation, Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. We were pleased to publish our second Virtual Issue in April 2016 on "Tissue Engineering in Bone" by Professor Tsuyoshi Takato. Our first was published in 2011 titled "Intra-Aortic Balloon Pumping" by Dr. Ashraf Khir. Other peer-reviewed Special Issues this year included contributions from the 11th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion edited by Dr. Akif Ündar and selections from the 23rd Congress of the International Society for Rotary Blood Pumps edited by Dr. Bojan Biocina. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Prevalence of Total Hip and Knee Replacement in the United States.

    PubMed

    Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J

    2015-09-02

    Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  5. Brazing graphite to graphite

    DOEpatents

    Peterson, George R.

    1976-01-01

    Graphite is joined to graphite by employing both fine molybdenum powder as the brazing material and an annealing step that together produce a virtually metal-free joint exhibiting properties similar to those found in the parent graphite. Molybdenum powder is placed between the faying surfaces of two graphite parts and melted to form molybdenum carbide. The joint area is thereafter subjected to an annealing operation which diffuses the carbide away from the joint and into the graphite parts. Graphite dissolved by the dispersed molybdenum carbide precipitates into the joint area, replacing the molybdenum carbide to provide a joint of virtually graphite.

  6. Influence of Total Knee Arthroplasty on Gait Mechanics of the Replaced and Non-Replaced Limb During Stair Negotiation.

    PubMed

    Standifird, Tyler W; Saxton, Arnold M; Coe, Dawn P; Cates, Harold E; Reinbolt, Jeffrey A; Zhang, Songning

    2016-01-01

    This study compared biomechanics during stair ascent in replaced and non-replaced limbs of total knee arthroplasty (TKA) patients with control limbs of healthy participants. Thirteen TKA patients and fifteen controls performed stair ascent. Replaced and non-replaced knees of TKA patients were less flexed at contact compared to controls. The loading response peak knee extension moment was greater in control and non-replaced knees compared with replaced. The push-off peak knee abduction moment was elevated in replaced limbs compared to controls. Loading and push-off peak hip abduction moments were greater in replaced limbs compared to controls. The push-off peak hip abduction moment was greater in non-replaced limbs compared to controls. Future rehabilitation protocols should consider the replaced knee and also the non-replaced knee and surrounding joints. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Intra-articular Enzyme Replacement Therapy with rhIDUA is Safe, Well-Tolerated, and Reduces Articular GAG Storage in the Canine Model of Mucopolysaccharidosis Type I

    PubMed Central

    Wang, Raymond Y; Aminian, Afshin; McEntee, Michael F; Kan, Shih-Hsin; Simonaro, Calogera M; Lamanna, William; Lawrence, Roger; Ellinwood, N. Matthew; Guerra, Catalina; Le, Steven Q; Dickson, Patricia I; Esko, Jeffrey D

    2014-01-01

    Background Treatment with intravenous enzyme replacement therapy and hematopoietic stem cell transplantation for mucopolysaccharidosis (MPS) type I does not address joint disease, resulting in persistent orthopedic complications and impaired quality of life. A proof-of-concept study was conducted to determine the safety, tolerability, and efficacy of intra-articular recombinant human iduronidase (IA-rhIDUA) enzyme replacement therapy in the canine MPS I model. Methods Four MPS I dogs underwent monthly rhIDUA injections (0.58 mg/joint) into the right elbow and knee for six months. Contralateral elbows and knees concurrently received normal saline. No intravenous rhIDUA therapy was administered. Monthly blood counts, chemistries, anti-rhIDUA antibody titers, and synovial fluid cell counts were measured. Lysosomal storage of synoviocytes and chondrocytes, synovial macrophages and plasma cells were scored at baseline and one month following the final injection. Results All injections were well-tolerated without adverse reactions. One animal required prednisone for spinal cord compression. There were no clinically significant abnormalities in blood counts or chemistries. Circulating anti-rhIDUA antibody titers gradually increased in all dogs except the prednisone-treated dog; plasma cells, which were absent in all baseline synovial specimens, were predominantly found in synovium of rhIDUA-treated joints at study-end. Lysosomal storage in synoviocytes and chondrocytes following 6 months of IA-rhIDUA demonstrated significant reduction compared to tissues at baseline, and saline-treated tissues at study-end. Mean joint synovial GAG levels in IA-rhIDUA joints was 8.62±5.86 μg/mg dry weight and 21.6±10.4 μg/mg dry weight in control joints (60% reduction). Cartilage heparan sulfate was also reduced in the IA-rhIDUA joints (113±39.5 ng/g wet weight) compared to saline-treated joints (142±56.4 ng/g wet weight). Synovial macrophage infiltration, which was present in all joints at baseline, was abolished in rhIDUA-treated joints only. Conclusions Intra-articular rhIDUA is well-tolerated and safe in the canine MPS I animal model. Qualitative and quantitative assessments indicate that IA-rhIDUA successfully reduces tissue and cellular GAG storage in synovium and articular cartilage, including cartilage deep to the articular surface, and eliminates inflammatory macrophages from synovial tissue. PMID:24951454

  8. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...

  9. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...

  10. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...

  11. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...

  12. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...

  13. Nature and origin of white efflorescence on bricks, artificial stones, and joint mortars of modern houses evaluated by portable Raman spectroscopy and laboratory analyses

    NASA Astrophysics Data System (ADS)

    Morillas, Héctor; Maguregui, Maite; Trebolazabala, Josu; Madariaga, Juan Manuel

    2015-02-01

    Bricks and mortar currently constitute one of the most important building materials used in the construction of most modern facades. The deterioration of these materials is caused primarily by the impact of numerous external stressors, while poor manufacturing quality, particularly of mortars, can also contribute to this process. In this work, the non-invasive Raman spectroscopy technique was used to identify the recently formed deterioration compounds (primarily sulfates and nitrates) in bricks, artificial stones, and joint mortars from detached houses in the Bilbao metropolitan area (Basque Country, North of Spain), as well as to investigate the deterioration processes taking place in these materials. Additionally, to confirm and in some cases complement the results obtained with Raman spectroscopy, SEM-EDS and XRD measurements were also carried out.

  14. Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain.

    PubMed

    Baker, Katherine M; Foutz, Timothy L; Johnsen, Kyle J; Budsberg, Steven C

    2014-09-01

    To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. 6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by TKR.

  15. Use of waste brick as a partial replacement of cement in mortar.

    PubMed

    Naceri, Abdelghani; Hamina, Makhloufi Chikouche

    2009-08-01

    The aim of this study is to investigate the use of waste brick as a partial replacement for cement in the production of cement mortar. Clinker was replaced by waste brick in different proportions (0%, 5%, 10%, 15% and 20%) by weight for cement. The physico-chemical properties of cement at anhydrous state and the hydrated state, thus the mechanical strengths (flexural and compressive strengths after 7, 28 and 90 days) for the mortar were studied. The microstructure of the mortar was investigated using scanning electron microscopy (SEM), the mineralogical composition (mineral phases) of the artificial pozzolan was investigated by the X-ray diffraction (XRD) and the particle size distributions was obtained from laser granulometry (LG) of cements powders used in this study. The results obtained show that the addition of artificial pozzolan improves the grinding time and setting times of the cement, thus the mechanical characteristics of mortar. A substitution of cement by 10% of waste brick increased mechanical strengths of mortar. The results of the investigation confirmed the potential use of this waste material to produce pozzolanic cement.

  16. Use of waste brick as a partial replacement of cement in mortar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naceri, Abdelghani; Hamina, Makhloufi Chikouche

    2009-08-15

    The aim of this study is to investigate the use of waste brick as a partial replacement for cement in the production of cement mortar. Clinker was replaced by waste brick in different proportions (0%, 5%, 10%, 15% and 20%) by weight for cement. The physico-chemical properties of cement at anhydrous state and the hydrated state, thus the mechanical strengths (flexural and compressive strengths after 7, 28 and 90 days) for the mortar were studied. The microstructure of the mortar was investigated using scanning electron microscopy (SEM), the mineralogical composition (mineral phases) of the artificial pozzolan was investigated by themore » X-ray diffraction (XRD) and the particle size distributions was obtained from laser granulometry (LG) of cements powders used in this study. The results obtained show that the addition of artificial pozzolan improves the grinding time and setting times of the cement, thus the mechanical characteristics of mortar. A substitution of cement by 10% of waste brick increased mechanical strengths of mortar. The results of the investigation confirmed the potential use of this waste material to produce pozzolanic cement.« less

  17. 21 CFR 888.6 - Degree of constraint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... replacement and prevents dislocation of the prosthesis in more than one anatomic plane and consists of either... translation and rotation of the prosthesis in one or more planes via the geometry of its articulating surfaces... total joint replacement and restricts minimally prosthesis movement in one or more planes. Its...

  18. Wear analysis and finishing of bioceramic implant surfaces.

    PubMed

    Denkena, Berend; Reichstein, Martin; van der Meer, Marijke; Ostermeier, Sven; Hurschler, Christof

    2008-01-01

    A primary cause for revision operations of joint replacements is the implant loosening, due to immune reactions resulting from the agglomeration of polyethylene wear debris. Motivated by the successful application of bioceramic materials in hip joint prostheses, a trend towards the development of hard implant materials has occurred. Nonetheless in the area of total knee arthroplasty (TKA), modern efforts have still utilized polyethylene as the tibial-inlay joint component. The use of bioceramic hard-hard-pairings for total knee arthroplasty has been prevented by the complex kinematics and geometries required. Ceramics cannot cope with non-uniform loads, which suggests the need for new designs appropriate to the material. Furthermore, biomechanical requirements should be considered. A rolling-gliding wear simulator, which reproduces the movements and stresses of the knee joint on specimens of simplified geometry, has therefore been developed. High-precision machining processes for free formed bioceramic surfaces, with suitable grinding and polishing tools which adjust to constantly changing contact conditions, are essential. The goal is to put automated finishing in one clamping with five simultaneous controlled axes into practice. The developed manufacturing technologies will allow the advantageous bioceramic materials to be applied and accepted for more complex joint replacements such as knee prostheses.

  19. Effects of artificial sweeteners on body weight, food and drink intake.

    PubMed

    Polyák, Eva; Gombos, K; Hajnal, B; Bonyár-Müller, K; Szabó, Sz; Gubicskó-Kisbenedek, A; Marton, K; Ember, I

    2010-12-01

    Artificial sweeteners are widely used all over the world. They may assist in weight management, prevention of dental caries, control of blood glucose of diabetics, and also can be used to replace sugar in foods. In the animal experimentation mice were given oral doses of water solutions of table top artificial sweeteners (saccharin, cyclamate based, acesulfame-K based, and aspartame) the amount of maximum Acceptable Daily Intake (ADI) ad libitum. The controls received only tap water with the same drinking conditions as the treated groups. The mice were fed chow ad libitum.We measured food intake and body weight once a week, water and solutions of artificial sweeteners intake twice a week. The data were analysed by statistical methods (T-probe, regression analysis).Consumption of sweeteners resulted in significantly increased body weight; however, the food intake did not change.These results question the effect of non-caloric artificial sweeteners on weight-maintenance or body weight decrease.

  20. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    PubMed

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage during placement. The framework presented may be useful for designing and testing customized devices for the treatment of debilitating bone and joint conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. The structure and functioning of Dynastab DK - K fixator (knee joint) and its usefullness in clinical use.

    PubMed

    Deszczyński, J; Karpiński, J; Deszczyńska, H

    1999-12-30

    The autor describes following stages of research on external fixator Dynastab DK - K (knee joint) with in - built artificial joint enabling physiological range of movement of the knee and the use of the device in functional treatment of articular fractures of the knee. The final clinical prototype of the device was developed according to the results of the experiments with anatomical preparations of knee joints in which the trajectory of the physiological movement of the knee was stated. These observations were used to construct mechanical joint with the range of movement adequate to this of the healthy knee. The positive and negative aspects in DK - K fixator are also described. The fixator was appled in 6 difficult cases of articular fractures of knee with good results.

  2. The Discover artificial disc replacement versus fusion in cervical radiculopathy--a randomized controlled outcome trial with 2-year follow-up.

    PubMed

    Skeppholm, Martin; Lindgren, Lars; Henriques, Thomas; Vavruch, Ludek; Löfgren, Håkan; Olerud, Claes

    2015-06-01

    Several previous studies comparing artificial disc replacement (ADR) and fusion have been conducted with cautiously positive results in favor of ADR. This study is not, in contrast to most previous studies, an investigational device exemption study required by the Food and Drug Administration for approval to market the product in the United States. This study was partially funded with unrestricted institutional research grants by the company marketing the artificial disc used in this study. To compare outcomes between the concepts of an artificial disc to treatment with anterior cervical decompression and fusion (ACDF) and to register complications associated to the two treatments during a follow-up time of 2 years. This is a randomized controlled multicenter trial, including three spine centers in Sweden. The study included patients seeking care for cervical radiculopathy who fulfilled inclusion criteria. In total, 153 patients were included. Self-assessment with Neck Disability Index (NDI) as a primary outcome variable and EQ-5D and visual analog scale as secondary outcome variables. Patients were randomly allocated to either treatment with the Depuy Discover artificial disc or fusion with iliac crest bone graft and plating. Randomization was blinded to both patient and caregivers until time for implantation. Adverse events, complications, and revision surgery were registered as well as loss of follow-up. Data were available in 137 (91%) of the included and initially treated patients. Both groups improved significantly after surgery. NDI changed from 63.1 to 39.8 in an intention-to-treat analysis. No statistically significant difference between the ADR and the ACDF groups could be demonstrated with NDI values of 39.1 and 40.1, respectively. Nor in secondary outcome measures (EQ-5D and visual analog scale) could any statistically significant differences be demonstrated between the groups. Nine patients in the ADR group and three in the fusion group underwent secondary surgery because of various reasons. Two patients in each group underwent secondary surgery because of adjacent segment pathology. Complication rates were not statistically significant between groups. Artificial disc replacement did not result in better outcome compared to fusion measured with NDI 2 years after surgery. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Presidential Green Chemistry Challenge: 2008 Designing Greener Chemicals Award

    EPA Pesticide Factsheets

    Presidential Green Chemistry Challenge 2008 award winner, Dow AgroSciences, used an artificial neural network to discover spinetoram, an improved spinosad biopesticide to replace organophosphates for key pests of fruit trees.

  4. Experimental study of physical properties of artificial materials for the development of the tissue-engineered valvular heart apparatus in comparison with biological analogs

    NASA Astrophysics Data System (ADS)

    Chiryatyeva, Aleksandra; Trebushat, Dmitry; Prokhorokhin, Aleksei; Khakhalkin, Vladimir; Andreev, Mark; Novokhreschenov, Aleksei; Kretov, Evgeny

    2017-12-01

    Cardiovascular diseases are the leading cause of death worldwide. Valvular heart disease often requires valve repair or replacement. Today, surgery uses xenograft—porcine or bovine pericardium. However, bioprosthetic valves do not ensure sufficient durability. We investigated 0.6% glutaraldehyde-treated porcine pericardium to define its properties. Using a tensile test stand, we studied characteristics of the polymeric material—expanded polytetrafluoroethylene (ePTFE)—and compared it to xenopericardium. The artificial material provides a better durability; it has higher elastic modulus and ultimate tensile strength. However, ePTFE samples demonstrated direction anisotropy due to extrusion features. It requires the enhancement of quality of the ePTFE sheet or investigation of other polymeric materials to find the adequate replacement for bioprosthetic heart valves.

  5. Comprehensive Care for Joint Replacement Model (CJR); Delay of Effective Date. Final rule; delay of effective date.

    PubMed

    2017-05-19

    This final rule finalizes May 20, 2017 as the effective date of the final rule titled "Advancing Care Coordination Through Episode Payment Models (EPMs); Cardiac Rehabilitation Incentive Payment Model; and Changes to the Comprehensive Care for Joint Replacement Model (CJR)" originally published in the January 3, 2017 Federal Register. This final rule also finalizes a delay of the applicability date of the regulations at 42 CFR part 512 from July 1, 2017 to January 1, 2018 and delays the effective date of the specific CJR regulations listed in the DATES section from July 1, 2017 to January 1, 2018.

  6. Sliding mode control for a two-joint coupling nonlinear system based on extended state observer.

    PubMed

    Zhao, Ling; Cheng, Haiyan; Wang, Tao

    2018-02-01

    A two-joint coupling nonlinear system driven by pneumatic artificial muscles is introduced in this paper. A sliding mode controller with extended state observer is proposed to cope with nonlinearities and disturbances for the two-joint coupling nonlinear system. In addition, convergence of the extended state observer is presented and stability analysis of the closed-loop system is also demonstrated with the sliding mode controller. Lastly, some experiments are carried out to show the reality effectiveness of the proposed method. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  7. An in vivo comparison study in goats for a novel motion-preserving cervical joint system

    PubMed Central

    Qin, Jie; Zhao, Chenguang; Wang, Dong; Zhao, Bo; Dong, Jun; Li, Haopeng; Sang, Rongxia; Wang, Shuang; Fu, Jiao; Kong, Rangrang

    2017-01-01

    Cervical degenerative disease is one of the most common spinal disorders worldwide, especially in older people. Anterior cervical corpectomy and fusion (ACCF) is a useful method for the surgical treatment of multi-level cervical degenerative disease. Anterior cervical disc replacement (ACDR) is considered as an alternative surgical method. However, both methods have drawbacks, particularly the neck motion decrease observed after arthrodesis, and arthroplasty should only be performed on patients presenting with cervical disc disease but without any vertebral body disease. Therefore, we designed a non-fusion cervical joint system, namely an artificial cervical vertebra and intervertebral complex (ACVC), to provide a novel treatment for multi-level cervical degenerative disease. To enhance the long-term stability of ACVC, we applied a hydroxyapatite (HA) biocoating on the surface of the artificial joint. Thirty-two goats were randomly divided into four groups: a sham control group, an ACVC group, an ACVC-HA group, and an ACCF group (titanium and plate fixation group). We performed the prosthesis implantation in our previously established goat model. We compared the clinical, radiological, biomechanical, and histological outcomes among these four different groups for 24 weeks post surgery. The goats successfully tolerated the entire experimental procedure. The kinematics data for the ACVC and ACVC-HA groups were similar. The range of motion (ROM) in adjacent level increased after ACCF but was not altered after ACVC or ACVC-HA implantation. Compared with the control group, no significant difference was found in ROM and neutral zone (NZ) in flexion-extension or lateral bending for the ACVC and ACVC-HA groups, whereas the ROM and NZ in rotation were significantly greater. Compared with the ACCF group, the ROM and NZ significantly increased in all directions. Overall, stiffness was significantly decreased in the ACVC and ACVC-HA groups compared with the control group and the ACCF group. Similar results were found after a fatigue test of 5,000 repetitions of axial rotation. The histological results showed more new bone formation and better bone implant contact in the ACVC-HA group than the ACVC group. Goat is an excellent animal model for cervical spine biomechanical study. Compared with the intact state and the ACCF group, ACVC could provide immediate stability and preserve segmental movement after discectomy and corpectomy. Besides, HA biocoating provide a better bone ingrowth, which is essential for long-term stability. In conclusion, ACVC-HA brings new insight to treat cervical degenerative disease. PMID:28582418

  8. Comparison of radiographic joint space width and magnetic resonance imaging for prediction of knee replacement: A longitudinal case-control study from the Osteoarthritis Initiative.

    PubMed

    Eckstein, Felix; Boudreau, Robert; Wang, Zhijie; Hannon, Michael J; Duryea, Jeff; Wirth, Wolfgang; Cotofana, Sebastian; Guermazi, Ali; Roemer, Frank; Nevitt, Michael; John, Markus R; Ladel, Christoph; Sharma, Leena; Hunter, David J; Kwoh, C Kent

    2016-06-01

    To evaluate whether change in fixed-location measures of radiographic joint space width (JSW) and cartilage thickness by MRI predict knee replacement. Knees replaced between 36 and 60 months' follow-up in the Osteoarthritis Initiative were each matched with one control by age, sex and radiographic status. Radiographic JSW was determined from fixed flexion radiographs and subregional femorotibial cartilage thickness from 3 T MRI. Changes between the annual visit before replacement (T0) and 2 years before T0 (T-2) were compared using conditional logistic regression. One hundred and nineteen knees from 102 participants (55.5 % women; age 64.2 ± 8.7 [mean ± SD] years) were studied. Fixed-location JSW change at 22.5 % from medial to lateral differed more between replaced and control knees (case-control [cc] OR = 1.57; 95 % CI: 1.23-2.01) than minimum medial JSW change (ccOR = 1.38; 95 % CI: 1.11-1.71). Medial femorotibial cartilage loss displayed discrimination similar to minimum JSW, and central tibial cartilage loss similar to fixed-location JSW. Location-independent thinning and thickening scores were elevated prior to knee replacement. Discrimination of structural progression between knee pre-placement cases versus controls was stronger for fixed-location than minimum radiographic JSW. MRI displayed similar discrimination to radiography and suggested greater simultaneous cartilage thickening and loss prior to knee replacement. • Fixed-location JSW predicts surgical knee replacement more strongly than minimum JSW. • MRI predicts knee replacement with similar accuracy to radiographic JSW. • MRI reveals greater cartilage thinning and thickening prior to knee replacement.

  9. An Exploratory Compressive Strength Of Concrete Containing Modified Artificial Polyethylene Aggregate (MAPEA)

    NASA Astrophysics Data System (ADS)

    Hadipramana, J.; Mokhatar, S. N.; Samad, A. A. A.; Hakim, N. F. A.

    2016-11-01

    Concrete is widely used in the world as building and construction material. However, the constituent materials used in concrete are high cost when associated with the global economic recession. This exploratory aspires to have an alternative source of replacing natural aggregate with plastic wastes. An investigation of the Modified Artificial Polyethylene Aggregate (MAPEA) as natural aggregate replacement in concrete through an experimental work was conducted in this study. The MAPEA was created to improve the bonding ability of Artificial Polyethylene Aggregate (APEA) with the cement paste. The concrete was mixed with 3%, 6%, 9%, and 12% of APEA and MAPEA for 14 and 28 curing days, respectively. Furthermore, the compressive strength test was conducted to find out the optimum composition of MAPEA in concrete and compared to the APEA concrete. Besides, this study observed the influence and behaviour of MAPEA in concrete. Therefore, the Scanning Electron Microscopy was applied to observe the microstructure of MAPEA and APEA concrete. The results showed the use of high composition of an artificial aggregate resulted inferior strength on the concrete and 3% MAPEA in the concrete mix was highest compressive strength than other content. The modification of APEA (MAPEA) concrete increased its strength due to its surface roughness. However, the interfacial zone cracking was still found and decreased the strength of MAPEA concrete especially when it was age 28 days.

  10. Biomechanics of the natural, arthritic, and replaced human ankle joint

    PubMed Central

    2014-01-01

    The human ankle joint complex plays a fundamental role in gait and other activities of daily living. At the same time, it is a very complicated anatomical system but the large literature of experimental and modelling studies has not fully described the coupled joint motion, position and orientation of the joint axis of rotation, stress and strain in the ligaments and their role in guiding and stabilizing joint motion, conformity and congruence of the articular surfaces, patterns of contact at the articular surfaces, patterns of rolling and sliding at the joint surfaces, and muscle lever arm lengths. The present review article addresses these issues as described in the literature, reporting the most recent relevant findings. PMID:24499639

  11. Deconstructing the function of maternal stimulation in offspring development: Insights from the artificial rearing model in rats.

    PubMed

    Lomanowska, Anna M; Melo, Angel I

    2016-01-01

    This article is part of a Special Issue on "Parental Care". Maternal behavior has an important function in stimulating adequate growth and development of the young. Several approaches have been used in primates and rodents to deconstruct and examine the influence of specific components of maternal stimulation on offspring development. These approaches include observational studies of typical mother-infant interactions and studies of the effects of intermittent or complete deprivation of maternal contact. In this review, we focus on one unique approach using rats that enables the complete control of maternal variables by means of rearing rat pups artificially without contact with the mother or litter, while maintaining stable nutrition, temperature and exposure to stressful stimuli. This artificial rearing model permits the removal and controlled replacement of relevant maternal and litter stimuli and has contributed valuable insights regarding the influence of these stimuli on various developmental outcomes. It also enables the analysis of factors implicated in social isolation itself and their long-term influence. We provide an overview of the effects of artificial rearing on behavior, physiology, and neurobiology, including the influence of replacing maternal tactile stimulation and littermate contact on these outcomes. We then discuss the relevance of these effects in terms of the maternal role in regulating different aspects of offspring development and implications for human research. We emphasize that artificial rearing of rats does not lead to a global insult of nervous system development, making this paradigm useful in investigating specific developmental effects associated with maternal stimulation. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Incorporation of a lambda phage recombination system and EGFP detection to simplify mutagenesis of Herpes simplex virus bacterial artificial chromosomes

    PubMed Central

    Schmeisser, Falko; Weir, Jerry P

    2007-01-01

    Background Targeted mutagenesis of the herpesvirus genomes has been facilitated by the use of bacterial artificial chromosome (BAC) technology. Such modified genomes have potential uses in understanding viral pathogenesis, gene identification and characterization, and the development of new viral vectors and vaccines. We have previously described the construction of a herpes simplex virus 2 (HSV-2) BAC and the use of an allele replacement strategy to construct HSV-2 recombinants. While the BAC mutagenesis procedure is a powerful method to generate HSV-2 recombinants, particularly in the absence of selective marker in eukaryotic culture, the mutagenesis procedure is still difficult and cumbersome. Results Here we describe the incorporation of a phage lambda recombination system into an allele replacement vector. This strategy enables any DNA fragment containing the phage attL recombination sites to be efficiently inserted into the attR sites of the allele replacement vector using phage lambda clonase. We also describe how the incorporation of EGFP into the allele replacement vector can facilitate the selection of the desired cross-over recombinant BACs when the allele replacement reaction is a viral gene deletion. Finally, we incorporate the lambda phage recombination sites directly into an HSV-2 BAC vector for direct recombination of gene cassettes using the phage lambda clonase-driven recombination reaction. Conclusion Together, these improvements to the techniques of HSV BAC mutagenesis will facilitate the construction of recombinant herpes simplex viruses and viral vectors. PMID:17501993

  13. Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouzounian, T.J.; Thompson, L.; Grogan, T.J.

    The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletalmore » sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement.« less

  14. Outcomes of a Joint Replacement Surgical Home Model Clinical Pathway

    PubMed Central

    Chaurasia, Avinash; Garson, Leslie; Kain, Zeev L.; Schwarzkopf, Ran

    2014-01-01

    Optimizing perioperative care to provide maximum benefit at minimum cost may be best achieved using a perioperative clinical pathway (PCP). Using our joint replacement surgical home (JSH) model PCP, we examined length of stay (LOS) following total joint arthroplasty (TJA) to evaluate patient care optimization. We reviewed a spectrum of clinical measurements in 190 consecutive patients who underwent TJA. Patients who had surgery earlier in the week and who were earlier cases of the day had a significantly lower LOS than patients whose cases started both later in the week and later in the day. Patients discharged home had significantly lower LOS than those discharged to a secondary care facility. Patients who received regional versus general anesthesia had a significantly lower LOS. Scheduling patients discharged to home and who will likely receive regional anesthesia for the earliest morning slot and earlier in the week may help decrease overall LOS. PMID:25025045

  15. Estimation of wear in total hip replacement using a ten station hip simulator.

    PubMed

    Brummitt, K; Hardaker, C S

    1996-01-01

    The results of hip simulator tests on a total of 16 total hip joints, all of them 22.25 mm Charnley designs, are presented. Wear at up to 6.75 million cycles was assessed by using a coordinate measuring machine. The results gave good agreement with clinical estimates of wear rate on the same design of joint replacement from a number of sources. Good agreement was also obtained when comparison was made with the published results from more sophisticated simulators. The major source of variation in the results was found to occur in the first million cycles where creep predominates. The results of this study support the use of this type of simplified simulator for estimating wear in a total hip prosthesis. The capability to test a significant number of joints simultaneously may make this mechanism preferable to more complex machines in many cases.

  16. Bundled Payments in Total Joint Replacement: Keeping Our Care Affordable and High in Quality.

    PubMed

    McLawhorn, Alexander S; Buller, Leonard T

    2017-09-01

    The purpose of this review was to evaluate the literature regarding bundle payment reimbursement models for total joint arthroplasty (TJA). From an economic standpoint, TJA are cost-effective, but they represent a substantial expense to the Centers for Medicare & Medicaid Services (CMS). Historically, fee-for-service payment models resulted in highly variable cost and quality. CMS introduced Bundled Payments for Care Improvement (BPCI) in 2012 and subsequently the Comprehensive Care for Joint Replacement (CJR) reimbursement model in 2016 to improve the value of TJA from the perspectives of both CMS and patients, by improving quality via cost control. Early results of bundled payments are promising, but preserving access to care for patients with high comorbidity burdens and those requiring more complex care is a lingering concern. Hospitals, regardless of current participation in bundled payments, should develop care pathways for TJA to maximize efficiency and patient safety.

  17. [Custom-made implant for complex facial reconstruction: A case of total replacement of temporo-mandibular joint, zygomatic arch and malar bone].

    PubMed

    Guillier, D; Moris, V; See, L-A; Girodon, M; Wajszczak, B-L; Zwetyenga, N

    2017-02-01

    Total prosthetic replacement of the temporo-mandibular joint (TMJ) has become a common procedure, but it is usually limited to the TMJ itself. We report about one case of complex prosthetic joint reconstruction extending to the neighbouring bony structures. A 57-year-old patient, operated several times for a cranio-facial fibrous dysplasia, presented with a recurring TMJ ankylosis and a complexe latero-facial bone loss on the right side. We performed a reconstruction procedure including the TMJ, the zygomatic arch and the malar bone by mean of custom made composite prosthesis (chrome-cobalt-molybdenum-titanium and polyethylene). Five years postoperatively, mouth opening, nutrition, pain and oral hygiene were significantly improved. Nowadays technical possibilities allow for complex facial alloplastic reconstructions with good medium term results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Measurement of installation deformation of the acetabulum during prosthetic replacement of a hip joint using digital image correlation

    NASA Astrophysics Data System (ADS)

    Lei, Dong; Bai, Pengxiang; Zhu, Feipeng

    2018-01-01

    Nowadays, acetabulum prosthesis replacement is widely used in clinical medicine. However, there is no efficient way to evaluate the implantation effect of the prosthesis. Based on a modern photomechanics technique called digital image correlation (DIC), the evaluation method of the installation effect of the acetabulum was established during a prosthetic replacement of a hip joint. The DIC method determines strain field by comparing the speckle images between the undeformed sample and the deformed counterpart. Three groups of experiments were carried out to verify the feasibility of the DIC method on the acetabulum installation deformation test. Experimental results indicate that the installation deformation of acetabulum generally includes elastic deformation (corresponding to the principal strain of about 1.2%) and plastic deformation. When the installation angle is ideal, the plastic deformation can be effectively reduced, which could prolong the service life of acetabulum prostheses.

  19. Kidney Replacement Therapy

    MedlinePlus

    ... week, and lasts 3 to 5 hours each time. Blood travels through the artificial kidney, where waste products are ... eat a more normal diet and have more time for work and travel. Peritoneal dialysis is not for everyone, however. A ...

  20. Tribology and total hip joint replacement: current concepts in mechanical simulation.

    PubMed

    Affatato, S; Spinelli, M; Zavalloni, M; Mazzega-Fabbro, C; Viceconti, M

    2008-12-01

    Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.

  1. Position of the prosthesis and the incidence of dislocation following total hip replacement.

    PubMed

    He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song

    2007-07-05

    Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.

  2. Satisfaction with joint replacement in public versus private hospitals: a cohort study.

    PubMed

    Adie, Sam; Dao, Alan; Harris, Ian A; Naylor, Justine M; Mittal, Rajat

    2012-09-01

    In Australia, the majority of total knee and hip replacement surgeries occur in the private sector. Outcome-based research needs to be inclusive of this sector if the findings are intended to reflect the broader picture. This study compares outcomes up to 1 year post knee and hip replacement between patients treated in the public and private sectors. A prospective, observational study was performed in four high-volume joint replacement centres: two public, two private. Experienced orthopaedic surgeons contributed via their public and private practices. Knee and hip patients were recruited preoperatively. Self-reported questionnaires were completed preoperatively and at 6 and 12 months post-operatively. The primary outcome was satisfaction with surgery. Secondary outcomes included Oxford score, and SF-36 physical and mental component summary scores. Regression modelling was performed to adjust for potential confounders. Three hundred and thirty-one patients (184 public, 147 private; 215 knees, 116 hips) were recruited, with 6- and 12-month follow-up rates of 95% and 89%, respectively. Satisfaction rates were high in both public and private patients (approximately 90%) at 6 and 12 months, but private patients were less likely to be satisfied after adjusting for the strong effect of patient expectation. For both hip and knee cohorts, no between-sector differences were found in either the magnitude or rate of improvement in Oxford score or quality of life post-operatively. Joint replacement outcomes are similar for patients treated in public and private hospitals. Surgeons should manage patient expectation prior to surgery, particularly in private patients. © 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.

  3. Clinical characteristics, microbiology, and outcomes of prosthetic joint infection in Taiwan.

    PubMed

    Tsai, Jen-Chih; Sheng, Wang-Huei; Lo, Wan-Yu; Jiang, Ching-Chuan; Chang, Shan-Chwen

    2015-04-01

    Prosthetic joint infection (PJI) after total knee or hip replacement is a devastating complication associated with substantial morbidity and economic cost. The incidence of prosthetic joint infection is increasing as the use of mechanical joint replacement increases. The treatment approach to prosthetic joint infection is based on different clinical situations such as a patient's comorbidities, epidemic microbiology data, and surgical procedures. The aim of our study was to understand clinical characteristics of prosthetic joint infection, the microbiology of the prosthetic joint infection, and the outcomes of different treatment strategies during 2006-2011. We retrospectively collected cases of prosthetic joint infection in the National Taiwan University Hospital between January 1, 2006 and December 31, 2011. The patients' characteristics, microbiology, outcomes, and factors associated with treatment success were recorded. One hundred and forty-four patients were identified as having PJI. Of these, 92 patients were entered into per-protocol analysis. Staphylococcus aureus was the most common causative organism (29.9%), followed by coagulase-negative Staphylococci (16.7%), and Enterococci (9.7%). The overall treatment success rate was 50%. Patients who received a two-stage revision had a better outcome, compared to patients who underwent other types of surgeries (70% vs. 32.7%, respectively; p < 0.001). In multivariate analysis, the two-stage revision was significantly associated with treatment success (odds ratio = 3.923, 95% confidence interval = 1.53-10.04). Our study demonstrates that Staphylococcus aureus was the most common causative organisms in PJI. Performing two-stage revisions was significantly associated with a better outcome. Copyright © 2013. Published by Elsevier B.V.

  4. Feasibility study of robotic neural controllers

    NASA Technical Reports Server (NTRS)

    Magana, Mario E.

    1990-01-01

    The results are given of a feasibility study performed to establish if an artificial neural controller could be used to achieve joint space trajectory tracking of a two-link robot manipulator. The study is based on the results obtained by Hecht-Nielsen, who claims that a functional map can be implemented to a desired degree of accuracy with a three layer feedforward artificial neural network. Central to this study is the assumption that the robot model as well as its parameters values are known.

  5. An investigation of the validity of six measures of physical function in people awaiting joint replacement surgery of the hip or knee.

    PubMed

    Gill, Stephen D; de Morton, Natalie A; Mc Burney, Helen

    2012-10-01

    To assess and compare the validity of six physical function measures in people awaiting hip or knee joint replacement. Eighty-two people awaiting hip or knee replacement were assessed using six physical function measures including the WOMAC Function scale, SF-36 Physical Function scale, SF-36 Physical Component Summary scale, Patient Specific Functional Scale, 30-second chair stand test, and 50-foot timed walk. Validity was assessed using a head-to-head comparison design. Convergent validity was demonstrated with significant correlations between most measures (Spearman's rho 0.22 to 0.71). The Patient Specific Functional Scale had the lowest correlations with other measures of physical function. Discriminant validity was demonstrated with low correlations between mental health and physical function scores (Spearman's rho -0.12 to 0.33). Only the WOMAC Function scale, 30-second chair stand test, and 50-foot timed walk demonstrated known groups validity when scores for participants who walked with a gait aid were compared with those who did not. Standardized response means and Guyatt's responsiveness indexes indicated that the SF-36 was the least responsive measure. For those awaiting joint replacement surgery of the hip or knee, the current investigation found that the WOMAC Function scale, 30-second chair stand test, and 50-foot timed walk demonstrated the most evidence of validity. The Patient Specific Functional Scale might complement other measures by capturing a different aspect of physical function.

  6. Geographic region, socioeconomic position and the utilisation of primary total joint replacement for hip or knee osteoarthritis across western Victoria: a cross-sectional multilevel study of the Australian Orthopaedic Association National Joint Replacement Registry.

    PubMed

    Brennan-Olsen, Sharon; Vogrin, Sara; Holloway, Kara L; Page, Richard S; Sajjad, Muhammad A; Kotowicz, Mark A; Livingston, Patricia M; Khasraw, Mustafa; Hakkennes, Sharon; Dunning, Trish L; Brumby, Susan; Pedler, Daryl; Sutherland, Alasdair; Venkatesh, Svetha; Williams, Lana J; Duque, Gustavo; Pasco, Julie A

    2017-11-06

    Compared to urban residents, those in rural/regional areas often experience inequitable healthcare from specialist service providers. Independent of small between-area differences in utilisation, socially advantaged groups had the greatest uptake of joint replacement. These data suggest low correlation between 'need' vs. 'uptake' of surgery in rural/regional areas. Compared to urban residents, those in rural and regional areas often experience inequitable healthcare from specialist service providers, often due to geographical issues. We investigated associations between socioeconomic position (SEP), region of residence and utilisation of primary total knee replacement (TKR) and/or total hip replacement (THR) for osteoarthritis. As part of the Ageing, Chronic Disease and Injury study, we extracted data from the Australian Orthopaedic Association National Joint Replacement Registry (2011-2013) for adults that utilised primary TKR (n = 4179; 56% female) and/or THR (n = 3120; 54% female). Residential addresses were matched with the Australian Bureau of Statistics (ABS) 2011 census data: region of residence was defined according to local government areas (LGAs), and area-level SEP (quintiles) defined using an ABS-derived composite index. The ABS-determined control population (n = 591,265; 51% female) excluded individuals identified as cases. We performed multilevel logistic regression modelling using a stratified two-stage cluster design. TKR was higher for those aged 70-79 years (AOR 1.4 95%CI 1.3-1.5; referent = 60-69 years) and in the most advantaged SEP quintile (AOR 2.1, 95%CI 1.8-2.3; referent = SEP quintile 3); results were similar for THR (70-79 years = AOR 1.7, 95%CI 1.5-1.8; SEP quintile 5 = AOR 2.5, 95%CI 2.2-2.8). Total variances contributed by the variance in LGAs were 2% (SD random effects ± 0.28) and 3% (SD ± 0.32), respectively. Independent of small between-LGA differences in utilisation, and in contrast to the expected greater prevalence of osteoarthritis in disadvantaged populations, we report greater TKR and THR in more advantaged groups. Further research should investigate whether more advantaged populations may be over-serviced.

  7. Evaluation of total alloplastic temporo-mandibular joint replacement with two different types of prostheses: A three-year prospective study

    PubMed Central

    Gonzalez-Perez-Somarriba, Borja; Centeno, Gabriel; Vallellano, Carpóforo; Montes-Carmona, Jose-Francisco

    2016-01-01

    Background Temporo-Mandibular Joint (TMJ) replacement has been used clinically for years. The objective of this study was to evaluate outcomes achieved in patients with two different categories of TMJ prostheses. Material and Methods All patients who had a TMJ replacement (TMJR) implanted during the study period from 2006 through 2012 were included in this 3-year prospective study. All procedures were performed using the Biomet Microfixation TMJ Replacement System, and all involved replacing both the skull base component (glenoid fossa) and the mandibular condyle. Results Fifty-seven patients (38 females and 19 males), involving 75 TMJs with severe disease requiring reconstruction (39 unilateral, 18 bilateral) were operated on consecutively, and 68 stock prostheses and 7 custom-made prostheses were implanted. The mean age at surgery was 52.6±11.5 years in the stock group and 51.8±11.7 years in the custom-made group. In the stock group, after three years of TMJR, results showed a reduction in pain intensity from 6.4±1.4 to 1.6±1.2 (p<0.001), and an improvement in jaw opening from 2.7±0.9 cm to 4.2±0.7 cm (p<0.001). In the custom-made group, after three years of TMJR, results showed a reduction in pain intensity from 6.0±1.6 to 2.2±0.4 (p<0.001), and an improvement in jaw opening from 1.5±0.5 cm to 4.3±0.6 cm (p<0.001). No statistically significant differences between two groups were detected. Conclusions The results of this three-year prospective study support the surgical placement of TMJ prostheses (stock prosthetic, and custom-made systems), and show that the approach is efficacious and safe, reduces pain, and improves maximum mouth opening movement, with few complications. As such, TMJR represents a viable technique and a stable long-term solution for cranio-mandibular reconstruction in patients with irreversible end-stage TMJ disease. Comparing stock and custom-made groups, no statistically significant differences were detected with respect to pain intensity reduction and maximum mouth opening improvement. Key words:Temporo-mandibular joint, temporo-mandibular joint replacement, prosthesis, biomaterials, biomedical engineering, computer-aided design and manufacturing. PMID:27475697

  8. Central Sensitization and Neuropathic Features of Ongoing Pain in a Rat Model of Advanced Osteoarthritis.

    PubMed

    Havelin, Joshua; Imbert, Ian; Cormier, Jennifer; Allen, Joshua; Porreca, Frank; King, Tamara

    2016-03-01

    Osteoarthritis (OA) pain is most commonly characterized by movement-triggered joint pain. However, in advanced disease, OA pain becomes persistent, ongoing and resistant to treatment with nonsteroidal anti-inflammatory drugs (NSAIDs). The mechanisms underlying ongoing pain in advanced OA are poorly understood. We recently showed that intra-articular (i.a.) injection of monosodium iodoacetate (MIA) into the rat knee joint produces concentration-dependent outcomes. Thus, a low dose of i.a. MIA produces NSAID-sensitive weight asymmetry without evidence of ongoing pain and a high i.a. MIA dose produces weight asymmetry and NSAID-resistant ongoing pain. In the present study, palpation of the ipsilateral hind limb of rats treated 14 days previously with high, but not low, doses of i.a. MIA produced expression of the early oncogene, FOS, in the spinal dorsal horn. Inactivation of descending pain facilitatory pathways using a microinjection of lidocaine within the rostral ventromedial medulla induced conditioned place preference selectively in rats treated with the high dose of MIA. Conditioned place preference to intra-articular lidocaine was blocked by pretreatment with duloxetine (30 mg/kg, intraperitoneally at -30 minutes). These observations are consistent with the likelihood of a neuropathic component of OA that elicits ongoing, NSAID-resistant pain and central sensitization that is mediated, in part, by descending modulatory mechanisms. This model provides a basis for exploration of underlying mechanisms promoting neuropathic components of OA pain and for the identification of mechanisms that might guide drug discovery for treatment of advanced OA pain without the need for joint replacement. Difficulty in managing advanced OA pain often results in joint replacement therapy in these patients. Improved understanding of mechanisms driving NSAID-resistant ongoing OA pain might facilitate development of alternatives to joint replacement therapy. Our findings suggest that central sensitization and neuropathic features contribute to NSAID-resistant ongoing OA joint pain. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  9. Nature and origin of white efflorescence on bricks, artificial stones, and joint mortars of modern houses evaluated by portable Raman spectroscopy and laboratory analyses.

    PubMed

    Morillas, Héctor; Maguregui, Maite; Trebolazabala, Josu; Madariaga, Juan Manuel

    2015-02-05

    Bricks and mortar currently constitute one of the most important building materials used in the construction of most modern facades. The deterioration of these materials is caused primarily by the impact of numerous external stressors, while poor manufacturing quality, particularly of mortars, can also contribute to this process. In this work, the non-invasive Raman spectroscopy technique was used to identify the recently formed deterioration compounds (primarily sulfates and nitrates) in bricks, artificial stones, and joint mortars from detached houses in the Bilbao metropolitan area (Basque Country, North of Spain), as well as to investigate the deterioration processes taking place in these materials. Additionally, to confirm and in some cases complement the results obtained with Raman spectroscopy, SEM-EDS and XRD measurements were also carried out. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Joint reproductive autonomy: does Evans v Amicus Healthcare Ltd provide for a gender-neutral approach to assisted reproductive rights?

    PubMed

    Allin, Michael J

    2015-06-01

    Assisted reproductive technology encompasses methods of achieving pregnancy by artificial or partially artificial means. Whilst these methods are more commonly used by couples suffering from problems of infertility, some forms of assistance are employed by fertile couples, for example pre-implantation genetic diagnosis. The overall regulatory framework in the UK is predominantly found in the Human Fertilisation and Embryology Act 1990. The usual rules relating to consent and autonomy apply and were discussed in depth in Evans v Amicus Healthcare Ltd and later in Evans v United Kingdom. This paper considers whether the Evans litigation envisages the possibility of further encouraging joint autonomy in the use of zygotes and whether there is a continuing right to autonomy by the party not bearing the pregnancy. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Converging flow joint insert system at an intersection between adjacent transitions extending between a combustor and a turbine assembly in a gas turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiebe, David J.; Carlson, Andrew; Stoker, Kyle C.

    A transition duct system for routing a gas flow in a combustion turbine engine is provided. The transition duct system includes one or more converging flow joint inserts forming a trailing edge at an intersection between adjacent transition ducts. The converging flow joint insert may be contained within a converging flow joint insert receiver and may be disconnected from the transition duct bodies by which the converging flow joint insert is positioned. Being disconnected eliminates stress formation within the converging flow joint insert, thereby enhancing the life of the insert. The converging flow joint insert may be removable such thatmore » the insert can be replaced once worn beyond design limits.« less

  12. Biomaterials in Artificial Organs.

    ERIC Educational Resources Information Center

    Kambic, Helen E.; And Others

    1986-01-01

    Biomaterials are substances or combinations of substances that can be used in a system that treats, augments, or replaces any tissue, organ, or body function. The nature and role of these substances, particularly in the cadiovascular system, are discussed. (JN)

  13. Contact allergic gastritis: an underdiagnosed entity?

    PubMed Central

    Pföhler, Claudia; Körner, Rebecca; Vogt, Thomas; Müller, Cornelia S L

    2012-01-01

    Only a few cases of contact allergic gastritis in patients with nickel allergy have been reported. We report a case of probable contact-allergic gastritis in a 46-year-old woman. Clinical examination revealed lichenoid mucosal lesions of the gums adjacent to bridges and crowns that had been implanted several weeks back. Since implantation, the patient had suffered from gastrointestinal complaints (including stomach pain). Gastroscopy showed eosinophilic gastritis. Patch testing done under the diagnosis of contact allergic stomatitis showed positive reactions to: gold sodium thiosulphate; manganese (II) chloride; nickel (II) sulphate; palladium chloride; vanadium (III) chloride and zirconium (IV) chloride. The crowns and bridge contained gold, palladium and zirconium chloride, hence they were replaced by titan-based dentition. Shortly after replacing the artificial dentition, all gastrointestinal symptoms resolved spontaneously without further treatment. Delayed-type allergy against the components of artificial dentition seemed to be the cause of gastritis. PMID:23192576

  14. Does location of rotation center in artificial disc affect cervical biomechanics?

    PubMed

    Mo, Zhongjun; Zhao, Yanbin; Du, Chengfei; Sun, Yu; Zhang, Ming; Fan, Yubo

    2015-04-15

    A 3-dimensional finite element investigation. To compare the biomechanical performances of different rotation centers (RCs) in the prevalent artificial cervical discs. Various configurations are applied in artificial discs. Design parameters may influence the biomechanics of implanted spine. The RC is a primary variation in the popular artificial discs. Implantation of 5 prostheses was simulated at C5-C6 on the basis of a validated finite element cervical model (C3-C7). The prostheses included ball-in-socket design with a fixed RC located on the inferior endplate (BS-FI) and on the superior endplate (BS-FS), with a mobile RC at the inferior endplate (BS-MI), dual articulation with a mobile RC between the endplates (DA-M), and sliding articulation with various RCs (SA-V). The spinal motions in flexion and extension served as a displacement loading at the C3 vertebrae. Total disc replacements reduced extension moment. The ball-in-socket designs required less flexion moment, whereas the flexion stiffness of the spines with DA-M and SA-V was similar to that of the healthy model. The contributions of the implanted level to the global motions increased in the total disc replacements, except in the SA-V and DA-M models (in flexion). Ball-in-socket designs produced severe stress distributions in facet cartilage, whereas DA-M and SA-V produced more severe stress distribution on the bone-implant interface. Cervical stability was extremely affected in extension and partially affected in flexion by total disc replacement. With the prostheses with mobile RC, cervical curvature was readjusted under a low follower load. The SA-V and BS-FS designs exhibited better performances in the entire segmental stiffness and in the stability of the operative level than the BS-MI and BS-FI designs in flexion. The 5 designs demonstrated varying advantages relative to the stress distribution in the facet cartilages and on the bone-implant interface. 5.

  15. An introduction to tribology.

    PubMed

    Norris, James A; Stabile, Kathryne J; Jinnah, Riyaz H

    2008-01-01

    Tribology is the study of friction, wear, lubrication mechanisms, and their interrelationships. Biotribiology focuses on understanding diarthrodial joints and has been a branch of tribology since 1973. Since then, biotribology has played a prominent role in the evaluation and development of joint prostheses, contributing to reduced wear and increased longevity. Total joint replacements are now common for arthritic patients and are also used in treating a variety of other orthopaedic conditions. For this reason, a complete understanding of the joint lubrication and microstructure that exists in nature is crucial. A subfield of biotribology, biomimetic tribology, has been formed with this goal in mind. This review covers the basic concepts of tribology, provides a brief historical perspective on joint prostheses, and presents the application of tribology in understanding diarthrodial and prosthetic joints.

  16. Importance of preclinical evaluation of wear in hip implant designs using simulator machines.

    PubMed

    Trommer, Rafael Mello; Maru, Márcia Marie

    2017-01-01

    Total hip arthroplasty (THA) is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common material combinations used in hip designs comprise metal-on-polymer (MoP), ceramic-on-polymer (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). However, when the design of the hip implant is concerned besides the materials used, several parameters can influence its wear performance. In this scenario, where the safety and efficacy for the patient are the main issues, it is fundamental to evaluate and predict the wear rate of the hip implant design before its use in THA. This is one of the issues that should be taken into account in the preclinical evaluation step of the product, in which simulated laboratory tests are necessary. However, it is fundamental that the applied motions and loads can reproduce the wear mechanisms physiologically observed in the patient. To replicate the in vivo angular displacements and loadings, special machines known as joint simulators are employed. This article focuses on the main characteristics related to the wear simulation of hip implants using mechanical simulators, giving information to surgeons, researchers, regulatory bodies, etc., about the importance of preclinical wear evaluation. A critical analysis is performed on the differences in the principles of operation of simulators and their effects on the final results, and about future trends in wear simulation.

  17. Experimental reconstruction of cervical esophageal defect with artificial esophagus made of polyurethane in a dog model.

    PubMed

    Jiang, H; Cui, Y; Ma, K; Gong, M; Chang, D; Wang, T

    2016-01-01

    The defect of esophagus after surgical excision in patients is usually replaced by autologous stomach, jejunum, or colon. The operation brings severe trauma and complications. Using artificial esophagus to replace the defect in situ can reduce the operative trauma, simplify the operative procedures, and decrease the influence to digestive function. A variety of experiments have been designed for developing a practical artificial esophagus. Nevertheless, a safe and reliable artificial esophagus is not yet available. The objective is to evaluate the possibility of the artificial esophagus made of non-degradable polyurethane materials being used in reconstruction of the segmental defect of cervical esophagus in beagles, observe the regeneration of esophageal tissue, and gather experience for future study. The cervical esophageal defects in 13 beagles were designed to 2-cm long and were constructed by the artificial esophagus made of non-degradable polyurethane materials. Nutrition supports were given after the operation. The operative mortality, anastomotic leakage, migration of artificial esophagus, and dysphagia were followed up. The regeneration of the esophageal tissues was evaluated by histopathology and immunohistochemical labeled streptavidin-biotin method. The surgical procedures were successfully completed in all beagles, and 12-month follow-ups were done. Only one beagle died of severe infection, and all others survived until being killed. The anastomotic leakage occurred in nine beagles, most of them (8/9) were cured after supportive therapy. The migration of artificial esophagus occurred in all 12 surviving beagles, and one artificial esophagus stayed in situ after migration. All 12 surviving beagles showed dysphagia with taking only fluid or soft food. No beagle died of malnutrition. The neo-esophagus was composed of granulation tissue, and the inner surface was covered by epithelium in 2-3 months completely. But the inner surface of neo-esophagus with artificial esophagus staying in situ after migration was not covered by epithelium, and the granulation tissue was infiltrated by a great deal of inflammatory cells. Antibodies against cytokeratin were positively expressed in epithelium of neo-esophagus. Up to 12 months after operation, antibodies against smooth muscle actin and desmin were both negatively expressed in neo-esophagus. The artificial esophagus made of non-degradable polyurethane reconstructing cervical esophageal defect is practicable. Although there are some problems, including anastomotic leakage, migration, and dysphagia, they are not lethal following good supportive therapy. The esophageal epithelium can regenerate with the supporting role of artificial esophagus. In the future, deformable artificial esophagus should be improved, and a much longer follow-up will be performed to evaluate whether the esophageal gland and skeletal muscle can regenerate. © 2014 International Society for Diseases of the Esophagus.

  18. Intra-articular enzyme replacement therapy with rhIDUA is safe, well-tolerated, and reduces articular GAG storage in the canine model of mucopolysaccharidosis type I.

    PubMed

    Wang, Raymond Y; Aminian, Afshin; McEntee, Michael F; Kan, Shih-Hsin; Simonaro, Calogera M; Lamanna, William C; Lawrence, Roger; Ellinwood, N Matthew; Guerra, Catalina; Le, Steven Q; Dickson, Patricia I; Esko, Jeffrey D

    2014-08-01

    Treatment with intravenous enzyme replacement therapy and hematopoietic stem cell transplantation for mucopolysaccharidosis (MPS) type I does not address joint disease, resulting in persistent orthopedic complications and impaired quality of life. A proof-of-concept study was conducted to determine the safety, tolerability, and efficacy of intra-articular recombinant human iduronidase (IA-rhIDUA) enzyme replacement therapy in the canine MPS I model. Four MPS I dogs underwent monthly rhIDUA injections (0.58 mg/joint) into the right elbow and knee for 6 months. Contralateral elbows and knees concurrently received normal saline. No intravenous rhIDUA therapy was administered. Monthly blood counts, chemistries, anti-rhIDUA antibody titers, and synovial fluid cell counts were measured. Lysosomal storage of synoviocytes and chondrocytes, synovial macrophages and plasma cells were scored at baseline and 1 month following the final injection. All injections were well-tolerated without adverse reactions. One animal required prednisone for spinal cord compression. There were no clinically significant abnormalities in blood counts or chemistries. Circulating anti-rhIDUA antibody titers gradually increased in all dogs except the prednisone-treated dog; plasma cells, which were absent in all baseline synovial specimens, were predominantly found in synovium of rhIDUA-treated joints at study-end. Lysosomal storage in synoviocytes and chondrocytes following 6 months of IA-rhIDUA demonstrated significant reduction compared to tissues at baseline, and saline-treated tissues at study-end. Mean joint synovial GAG levels in IA-rhIDUA joints were 8.62 ± 5.86 μg/mg dry weight and 21.6 ± 10.4 μg/mg dry weight in control joints (60% reduction). Cartilage heparan sulfate was also reduced in the IA-rhIDUA joints (113 ± 39.5 ng/g wet weight) compared to saline-treated joints (142 ± 56.4 ng/g wet weight). Synovial macrophage infiltration, which was present in all joints at baseline, was abolished in rhIDUA-treated joints only. Intra-articular rhIDUA is well-tolerated and safe in the canine MPS I animal model. Qualitative and quantitative assessments indicate that IA-rhIDUA successfully reduces tissue and cellular GAG storage in synovium and articular cartilage, including cartilage deep to the articular surface, and eliminates inflammatory macrophages from synovial tissue. The MPS I canine IA-rhIDUA results suggest that clinical studies should be performed to determine if IA-rhIDUA is a viable approach to ameliorating refractory orthopedic disease in human MPS I. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Validation study of the Forgotten Joint Score-12 as a universal patient-reported outcome measure.

    PubMed

    Matsumoto, Mikio; Baba, Tomonori; Homma, Yasuhiro; Kobayashi, Hideo; Ochi, Hironori; Yuasa, Takahito; Behrend, Henrik; Kaneko, Kazuo

    2015-10-01

    The Forgotten Joint Score-12 (FJS-12) is for patients to forget their artificial joint and is reportedly a useful patient-reported outcome tool for artificial joints. The purpose of this study was to determine whether the FJS-12 is as useful as the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) or the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ) in Japan. All patients who visited our hospital's hip joint specialists following unilateral THA from August 2013 to July 2014 were evaluated. Medical staff members other than physicians administered three questionnaires. Items evaluated were (1) the reliability of the FJS-12 and (2) correlations between the FJS-12 and the total and subscale scores of the WOMAC or JHEQ. Of 130 patients, 22 were excluded. Cronbach's α coefficient was 0.97 for the FJS-12. The FJS-12 showed a significantly lower score than the WOMAC or JHEQ (p < 0.01). The FJS-12 was moderately correlated with the total WOMAC score (r = 0.522) and its subscale scores for "stiffness" (r = 0.401) and "function" (r = 0.539) and was weakly correlated with the score for "pain" (r = 0.289). The FJS-12 was favorably correlated with the total JHEQ score (r = 0.686) and its subscale scores (r = 0.530-0.643). The FJS-12 was correlated with and showed reliability similar to that of the JHEQ and WOMAC. The FJS-12, which is not affected by culture or lifestyle, may be useful in Japan.

  20. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices... Medical Devices—Part I: Evaluation and Testing,’ ” (ii) “510(k) Sterility Review Guidance of 2/12/90 (K90... device intended to be implanted to replace part of a knee joint in the treatment of primary...

  1. 77 FR 68103 - Foreign-Trade Zone 163-Ponce, PR; Notification of Proposed Production Activity; Zimmer...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-15

    ..., rods, angles shapes and sections of stainless steel; articles of iron or steel; and, artificial joints... information, contact Elizabeth Whiteman at [email protected] or (202) 482-0473. Dated: November 5...

  2. [Succession pattern of artificial vegetation community and its ecological mechanism in an arid desert region].

    PubMed

    Xu, Cailin; Li, Zizhen

    2003-09-01

    Focusing on the artificial vegetation protection system of the Shapotou section of Baotou-Lanzhou railway in the arid desert region of China, this paper examined the dynamics of dominant plant species and the succession pattern of artificial plant community in the process of establishing and developing regional artificial vegetation. It also studied the driving force and the ecologically intrinsic mechanism of the community succession. The results demonstrated that the species composition of the artificial vegetation dramatically changed after 40 years of succession, from original artificial plant community of shrub and semi-shrub to artificial-natural desert plant community with annual herb dominated. During the process of succession, the importance values of artificial shrubs, such as Caragana korshinskii and Hedysarum scoparius, decreased and gradually retreated from the artificial plant community, while the naturally multiplied annual herb, such as Eragrostis poaeoides, Bassia dasyphylla, Salsola ruthenica, Chloris virgata and etc., were presented one after another and gradually became dominant. Besides, Artemisia ordosica always played a key role in the community due to its ability of naturally sowing and self-replacement. This type of succession pattern was closely related to the shortage of precipitation resource in this region and the formation of soil crust which inhibited the reproduction of shrub and perennial herb with deep root systems. This study provided a theoretical ground for realizing persistent development of artificial plant community.

  3. Revision Rates after Primary Hip and Knee Replacement in England between 2003 and 2006

    PubMed Central

    Sibanda, Nokuthaba; Copley, Lynn P; Lewsey, Jim D; Borroff, Mick; Gregg, Paul; MacGregor, Alex J; Pickford, Martin; Porter, Martyn; Tucker, Keith; van der Meulen, Jan H

    2008-01-01

    Background Hip and knee replacement are some of the most frequently performed surgical procedures in the world. Resurfacing of the hip and unicondylar knee replacement are increasingly being used. There is relatively little evidence on their performance. To study performance of joint replacement in England, we investigated revision rates in the first 3 y after hip or knee replacement according to prosthesis type. Methods and Findings We linked records of the National Joint Registry for England and Wales and the Hospital Episode Statistics for patients with a primary hip or knee replacement in the National Health Service in England between April 2003 and September 2006. Hospital Episode Statistics records of succeeding admissions were used to identify revisions for any reason. 76,576 patients with a primary hip replacement and 80,697 with a primary knee replacement were included (51% of all primary hip and knee replacements done in the English National Health Service). In hip patients, 3-y revision rates were 0.9% (95% confidence interval [CI] 0.8%–1.1%) with cemented, 2.0% (1.7%–2.3%) with cementless, 1.5% (1.1%–2.0% CI) with “hybrid” prostheses, and 2.6% (2.1%–3.1%) with hip resurfacing (p < 0.0001). Revision rates after hip resurfacing were increased especially in women. In knee patients, 3-y revision rates were 1.4% (1.2%–1.5% CI) with cemented, 1.5% (1.1%–2.1% CI) with cementless, and 2.8% (1.8%–4.5% CI) with unicondylar prostheses (p < 0.0001). Revision rates after knee replacement strongly decreased with age. Interpretation Overall, about one in 75 patients needed a revision of their prosthesis within 3 y. On the basis of our data, consideration should be given to using hip resurfacing only in male patients and unicondylar knee replacement only in elderly patients. PMID:18767900

  4. The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction.

    PubMed

    Gibon, Emmanuel; Córdova, Luis A; Lu, Laura; Lin, Tzu-Hua; Yao, Zhenyu; Hamadouche, Moussa; Goodman, Stuart B

    2017-08-01

    Novel evidence-based prosthetic designs and biomaterials facilitate the performance of highly successful joint replacement (JR) procedures. To achieve this goal, constructs must be durable, biomechanically sound, and avoid adverse local tissue reactions. Different biomaterials such as metals and their alloys, polymers, ceramics, and composites are currently used for JR implants. This review focuses on (1) the biological response to the different biomaterials used for TJR and (2) the chronic inflammatory and foreign-body response induced by byproducts of these biomaterials. A homeostatic state of bone and surrounding soft tissue with current biomaterials for JR can be achieved with mechanically stable, infection free and intact (as opposed to the release of particulate or ionic byproducts) implants. Adverse local tissue reactions (an acute/chronic inflammatory reaction, periprosthetic osteolysis, loosening and subsequent mechanical failure) may evolve when the latter conditions are not met. This article (Part 2 of 2) summarizes the biological response to the non-metallic materials commonly used for joint replacement including polyethylene, ceramics, and polymethylmethacrylate (PMMA), as well as the foreign body reaction to byproducts of these materials. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1685-1691, 2017. © 2016 Wiley Periodicals, Inc.

  5. Shoulder Arthroplasty, from Indications to Complications: What the Radiologist Needs to Know.

    PubMed

    Lin, Dana J; Wong, Tony T; Kazam, Jonathan K

    2016-01-01

    The replaced shoulder is increasingly encountered by the radiologist, both on a dedicated and incidental basis, in this era of the growing population of aging patients wishing to preserve their mobility and function. Knowledge of the normal biomechanics of the glenohumeral joint-particularly the function of the rotator cuff and the unique relationship of the humeral head to the glenoid-is essential for understanding the need for shoulder replacement and its subsequent complications, because the intent of shoulder arthroplasty is to approximate the normal joint as closely as possible. The most common indications for shoulder arthroplasty are osteoarthritis, inflammatory arthritis, proximal humerus fractures, irreparable rotator cuff tears, rotator cuff arthropathy, and avascular necrosis of the humeral head. Knowledge of the key imaging features of these indications helps facilitate a correlative understanding between the initial diagnosis and the choice of which type of arthroplasty is used-total shoulder arthroplasty, reverse total shoulder arthroplasty, or partial joint replacement (humeral head resurfacing arthroplasty or hemiarthroplasty). The preoperative requirements and usual postoperative appearance of each arthroplasty type are summarized, as well as the complications of shoulder arthroplasty, including those unique to or closely associated with each type of arthroplasty and those that can be encountered with any type of shoulder arthroplasty. ©RSNA, 2016.

  6. A Qualitative Study of Factors Underlying Decision Making for Joint Replacement among African Americans and Latinos with Osteoarthritis

    PubMed Central

    Parks, Michael L.; Hebert-Beirne, Jennifer; Rojas, Mary; Tuzzio, Leah; Nelson, Charles L.; Boutin-Foster, Carla

    2015-01-01

    To support patients in making decisions that align with their unique cultural beliefs, an understanding of factors underlying patient preferences is needed. We sought to identify psychosocial factors that influenced decision making among African-American and Hispanic patients referred for knee or hip arthroplasty. Thirty-six participants deciding on surgery were interviewed. Responses were audio-taped, transcribed, and read. Codes were assigned to the raw data and then clustered into categories that were analyzed to yield overarching themes. This process was repeated independently by two corroborators. Six categories described the mental calculations made in patients' decision-making processes: 1) self-assessment of ft for surgery based on age and comorbidity, 2) research and development of mental report cards of their surgeons, 3) reliving of social network experiences, 4) reliance on faith and spirituality for guidance, 5) acknowledgment of fear and anxiety, and 6) setting expectations for recovery. This study advanced the understanding of how decisions about joint replacement are constructed and identified cultural levers that can be targeted for intervention. Developing culturally tailored health information that addresses some of our findings and disseminating messages through social networks may reduce the underutilization of joint replacement among racial and ethnic minority populations. PMID:25272219

  7. A qualitative study of factors underlying decision making for joint replacement among African Americans and Latinos with osteoarthritis.

    PubMed

    Parks, Michael L; Hebert-Beirne, Jennifer; Rojas, Mary; Tuzzio, Leah; Nelson, Charles L; Boutin-Foster, Carla

    2014-01-01

    To support patients in making decisions that align with their unique cultural beliefs, an understanding of factors underlying patient preferences is needed. We sought to identify psychosocial factors that influenced decision making among African-American and Hispanic patients referred for knee or hip arthroplasty. Thirty-six participants deciding on surgery were interviewed. Responses were audio-taped, transcribed, and read. Codes were assigned to the raw data and then clustered into categories that were analyzed to yield overarching themes. This process was repeated independently by two corroborators. Six categories described the mental calculations made in patients' decision-making processes: 1) self-assessment of fit for surgery based on age and comorbidity, 2) research and development of mental report cards of their surgeons, 3) reliving of social network experiences, 4) reliance on faith and spirituality for guidance, 5) acknowledgment of fear and anxiety, and 6) setting expectations for recovery. This study advanced the understanding of how decisions about joint replacement are constructed and identified cultural levers that can be targeted for intervention. Developing culturally tailored health information that addresses some of our findings and disseminating messages through social networks may reduce the underutilization of joint replacement among racial and ethnic minority populations.

  8. Surgical Treatment for Discogenic Low-Back Pain: Lumbar Arthroplasty Results in Superior Pain Reduction and Disability Level Improvement Compared With Lumbar Fusion

    PubMed Central

    2007-01-01

    Background The US Food and Drug Administration approved the Charité artificial disc on October 26, 2004. This approval was based on an extensive analysis and review process; 20 years of disc usage worldwide; and the results of a prospective, randomized, controlled clinical trial that compared lumbar artificial disc replacement to fusion. The results of the investigational device exemption (IDE) study led to a conclusion that clinical outcomes following lumbar arthroplasty were at least as good as outcomes from fusion. Methods The author performed a new analysis of the Visual Analog Scale pain scores and the Oswestry Disability Index scores from the Charité artificial disc IDE study and used a nonparametric statistical test, because observed data distributions were not normal. The analysis included all of the enrolled subjects in both the nonrandomized and randomized phases of the study. Results Subjects from both the treatment and control groups improved from the baseline situation (P < .001) at all follow-up times (6 weeks to 24 months). Additionally, these pain and disability levels with artificial disc replacement were superior (P < .05) to the fusion treatment at all follow-up times including 2 years. Conclusions The a priori statistical plan for an IDE study may not adequately address the final distribution of the data. Therefore, statistical analyses more appropriate to the distribution may be necessary to develop meaningful statistical conclusions from the study. A nonparametric statistical analysis of the Charité artificial disc IDE outcomes scores demonstrates superiority for lumbar arthroplasty versus fusion at all follow-up time points to 24 months. PMID:25802574

  9. Obesity & osteoarthritis

    PubMed Central

    King, Lauren K.; March, Lyn; Anandacoomarasamy, Ananthila

    2013-01-01

    The most significant impact of obesity on the musculoskeletal system is associated with osteoarthritis (OA), a disabling degenerative joint disorder characterized by pain, decreased mobility and negative impact on quality of life. OA pathogenesis relates to both excessive joint loading and altered biomechanical patterns together with hormonal and cytokine dysregulation. Obesity is associated with the incidence and progression of OA of both weight-bearing and non weight-bearing joints, to rate of joint replacements as well as operative complications. Weight loss in OA can impart clinically significant improvements in pain and delay progression of joint structural damage. Further work is required to determine the relative contributions of mechanical and metabolic factors in the pathogenesis of OA. PMID:24056594

  10. CRITICAL ANALYSIS OF ARTIFICIAL TEETH FOR ENDODONTIC TEACHING

    PubMed Central

    Nassri, Maria Renata Giazzi; Carlik, Jaime; da Silva, Camila Roberta Nepomuceno; Okagawa, Renata Elisa; Lin, Suzy

    2008-01-01

    The purpose of this study was to evaluate the use of artificial teeth for endodontic teaching. A questionnaire was prepared and submitted to 18 professors of Endodontics from different Brazilian universities to evaluate the following features of five cloudy resin artificial teeth: internal and external anatomy; coronal chambers regarding their size, shape and canal path; root canal regarding their size, shape and position; fulfillment of the pulp chamber and root canals by considering the texture, quantity, color, and ease of handling; resin hardness and visualization of the radiographic image. The results presented favorable opinions, in terms of internal and external anatomy, coronal pulp chambers and root canal and handling and radiographic imaging. The contents of the pulp space and hardness of the teeth were considered satisfactory. The average grade assigned to the artificial tooth quality was 8.4, in a 0-10 scale. In conclusion, the artificial teeth have potential to replace the natural teeth in endodontic teaching; however, improvements are still necessary to reach a better quality model. PMID:19089288

  11. Critical analysis of artificial teeth for endodontic teaching.

    PubMed

    Nassri, Maria Renata Giazzi; Carlik, Jaime; da Silva, Camila Roberta Nepomuceno; Okagawa, Renata Elisa; Lin, Suzy

    2008-01-01

    The purpose of this study was to evaluate the use of artificial teeth for endodontic teaching. A questionnaire was prepared and submitted to 18 professors of Endodontics from different Brazilian universities to evaluate the following features of five cloudy resin artificial teeth: internal and external anatomy; coronal chambers regarding their size, shape and canal path; root canal regarding their size, shape and position; fulfillment of the pulp chamber and root canals by considering the texture, quantity, color, and ease of handling; resin hardness and visualization of the radiographic image. The results presented favorable opinions, in terms of internal and external anatomy, coronal pulp chambers and root canal and handling and radiographic imaging. The contents of the pulp space and hardness of the teeth were considered satisfactory. The average grade assigned to the artificial tooth quality was 8.4, in a 0-10 scale. In conclusion, the artificial teeth have potential to replace the natural teeth in endodontic teaching; however, improvements are still necessary to reach a better quality model.

  12. The Need for an Implant Identification Card at Airport Security Check

    PubMed Central

    Kosuge, Dennis; MacDowell, Andrew

    2017-01-01

    Background Joint replacement surgery is having an increasing demand as national healthcare systems confront an ever ageing population. Surgical complications associated with lower limb arthroplasty are well known but less investigation has been performed examining its effect on air travel, more specifically, unwanted and significant inconvenience caused to travelers going through airport security. Methods In lower limb arthroplasty clinics, 50 patients who met our selection criteria were given questionnaires. Ten airport security officers from 4 international airports (London Stansted, London Gatwick, London Heathrow, and Amsterdam Schiphol International Airport) were also given a separate questionnaire. The opinion of the Civil Aviation Authority was also sought. Results All 50 patients (mean age, 70.4 years; range, 55 to 84 years) who were presenting in lower limb arthroplasty clinics and who met our selection criteria volunteered to enter the study. Twenty-eight of these patients were female (mean age, 69.1 years; range, 55 to 84 years) and 22 were male (mean age, 71.2 years; range, 58 to 81 years). Of the patients, 14% stated that their joint replacements did not set off the airport security alarm. Responses were received from 10 airport security officers as well. Six airport security officers were male and 4 were female. All of the airport officers were aware of some form of implant identification card with 90% stating that these were useful to them at airport security. Eight-four percent of the patients stated that an implant identification card outlining what joint replacement they possessed and when this had been done would be very useful. Sixteen percent of the patients did not think a card would be beneficial since all of them had set off the airport alarm system only once or less in their lifetime. Conclusions It is the opinion of airport security officers and patients that joint replacement implant identification cards streamline airport security checks and decrease the need for more invasive searches at airport security. PMID:28567216

  13. The Need for an Implant Identification Card at Airport Security Check.

    PubMed

    Ali, Erden; Kosuge, Dennis; MacDowell, Andrew

    2017-06-01

    Joint replacement surgery is having an increasing demand as national healthcare systems confront an ever ageing population. Surgical complications associated with lower limb arthroplasty are well known but less investigation has been performed examining its effect on air travel, more specifically, unwanted and significant inconvenience caused to travelers going through airport security. In lower limb arthroplasty clinics, 50 patients who met our selection criteria were given questionnaires. Ten airport security officers from 4 international airports (London Stansted, London Gatwick, London Heathrow, and Amsterdam Schiphol International Airport) were also given a separate questionnaire. The opinion of the Civil Aviation Authority was also sought. All 50 patients (mean age, 70.4 years; range, 55 to 84 years) who were presenting in lower limb arthroplasty clinics and who met our selection criteria volunteered to enter the study. Twenty-eight of these patients were female (mean age, 69.1 years; range, 55 to 84 years) and 22 were male (mean age, 71.2 years; range, 58 to 81 years). Of the patients, 14% stated that their joint replacements did not set off the airport security alarm. Responses were received from 10 airport security officers as well. Six airport security officers were male and 4 were female. All of the airport officers were aware of some form of implant identification card with 90% stating that these were useful to them at airport security. Eight-four percent of the patients stated that an implant identification card outlining what joint replacement they possessed and when this had been done would be very useful. Sixteen percent of the patients did not think a card would be beneficial since all of them had set off the airport alarm system only once or less in their lifetime. It is the opinion of airport security officers and patients that joint replacement implant identification cards streamline airport security checks and decrease the need for more invasive searches at airport security.

  14. Growing Three-Dimensional Cartilage-Cell Cultures

    NASA Technical Reports Server (NTRS)

    Spaulding, Glenn F.; Prewett, Tacey L.; Goodwin, Thomas J.

    1995-01-01

    Process for growing three-dimensional cultures of mammalian cartilage from normal mammalian cells devised. Effected using horizontal rotating bioreactor described in companion article, "Simplified Bioreactor for Growing Mammalian Cells" (MSC-22060). Bioreactor provides quiescent environment with generous supplies of nutrient and oxygen. Initiated with noncartilage cells. Artificially grown tissue resembles that in mammalian cartilage. Potential use in developing therapies for damage to cartilage by joint and back injuries and by such inflammatory diseases as arthritis and temporal-mandibular joint disease. Also used to test nonsteroid anti-inflammation medicines.

  15. Neural network expert system for X-ray analysis of welded joints

    NASA Astrophysics Data System (ADS)

    Kozlov, V. V.; Lapik, N. V.; Popova, N. V.

    2018-03-01

    The use of intelligent technologies for the automated analysis of product quality is one of the main trends in modern machine building. At the same time, rapid development in various spheres of human activity is experienced by methods associated with the use of artificial neural networks, as the basis for building automated intelligent diagnostic systems. Technologies of machine vision allow one to effectively detect the presence of certain regularities in the analyzed designation, including defects of welded joints according to radiography data.

  16. Joint health and functional ability in children with haemophilia who receive intensive replacement therapy.

    PubMed

    Groen, W; van der Net, J; Bos, K; Abad, A; Bergstrom, B-M; Blanchette, V S; Feldman, B M; Funk, S; Helders, P; Hilliard, P; Manco-Johnson, M; Petrini, P; Zourikian, N; Fischer, K

    2011-09-01

    Joint physical examination is an important outcome in haemophilia; however its relationship with functional ability is not well established in children with intensive replacement therapy. Boys aged 4-16 years were recruited from two European and three North American treatment centres. Joint physical structure and function was measured with the Haemophilia Joint Health Score (HJHS) while functional ability was measured with the revised Childhood Health Assessment Questionnaire (CHAQ₃₈. Two haemophilia-specific domains were created by selecting items of the CHAQ₃₈ that cover haemophilia-specific problems. Associations between CHAQ, HJHS, cumulative number of haemarthroses and age were assessed. A total of 226 subjects - mean 10.8 years old (SD 3.8) - participated; the majority (68%) had severe haemophilia. Most severe patients (91%) were on prophylactic treatment. Lifetime number of haemarthroses [median=5; interquartile range (IQR)=1-12] and total HJHS (median = 5; IQR=1-12) correlated strongly (ρ = 0.51). Total HJHS did not correlate with age and only weakly (ρ=-0.19) with functional ability scores (median=0; IQR=-0.06-0). Overall, haemarthroses were reported most frequently in the ankles. Detailed analysis of ankle joint health scores revealed moderate associations (ρ=0.3-0.5) of strength, gait and atrophy with lower extremity tasks (e.g. stair climbing). In this population, HJHS summating six joints did not perform as well as individual joint scores, however, certain elements of ankle impairment, specifically muscle strength, atrophy and gait associated significantly with functional loss in lower extremity activities. Mild abnormalities in ankle assessment by HJHS may lead to functional loss. Therefore, ankle joints may warrant special attention in the follow up of these children. © 2011 Blackwell Publishing Ltd.

  17. Public priorities for joint pain research: results from a general population survey

    PubMed Central

    Carter, Pam; Ong, Bie Nio; Bedson, John; Jordan, Kelvin P.; Jinks, Clare

    2012-01-01

    Objective. We aimed to identify the priorities for joint pain research from a large general population survey and identify characteristics associated with these priorities. Methods. A question about research priorities was developed in collaboration with the Arthritis Research UK Primary Care Centre’s Research Users’ Group. The question was embedded in a postal survey to an existing cohort of adults with self-reported joint pain, aged ≥56 years, in North Staffordshire. Respondents were asked to rank their top three priorities for research. Factor mixture modelling was used to determine subgroups of priorities. Results. In all, 1756 (88%) people responded to the survey. Of these, 1356 (77%) gave three priorities for research. Keeping active was rated the top priority by 38%, followed by research around joint replacement (9%) and diet/weight loss (9%). Two clusters of people were identified: 62% preferred lifestyle/self-management topics (e.g. keeping active, weight loss) and 38% preferred medical intervention topics (e.g. joint replacement, tablets). Those who preferred the medical options tended to be older and have hip or foot pain. Conclusion. This study has provided population data on priorities for joint pain research expressed by a large cohort of older people who report joint pain. The most popular topics for research were linked to lifestyle and self-management opportunities. Pharmaceutical and invasive interventions, despite being common topics of research, are of less importance to these respondents than non-medical topics. Specific research questions will be generated from this study with collaboration of the patient’s group. PMID:22886341

  18. Microstructure of friction stir welded joints of 2017A aluminium alloy sheets.

    PubMed

    Mroczka, K; Dutkiewicz, J; Pietras, A

    2010-03-01

    The present study examines a friction stir welded 2017A aluminium alloy. Transmission electron microscope investigations of the weld nugget revealed the average grain size of 5 microm, moderate density of dislocations as well as the presence of nanometric precipitates located mostly in grains interiors. Scanning electron microscope observations of fractures showed the presence of ductile fracture in the region of the weld nugget with brittle precipitates in the lower part. The microhardness analysis performed on the cross-section of the joints showed fairly small changes; however, after the artificial ageing process an increase in hardness was observed. The change of the joint hardness subject to the ageing process indicates partial supersaturation in the material during friction stir welding and higher precipitation hardening of the joint.

  19. Cost-Effectiveness of Total Hip and Knee Replacements for the Australian Population with Osteoarthritis: Discrete-Event Simulation Model

    PubMed Central

    Higashi, Hideki; Barendregt, Jan J.

    2011-01-01

    Background Osteoarthritis constitutes a major musculoskeletal burden for the aged Australians. Hip and knee replacement surgeries are effective interventions once all conservative therapies to manage the symptoms have been exhausted. This study aims to evaluate the cost-effectiveness of hip and knee replacements in Australia. To our best knowledge, the study is the first attempt to account for the dual nature of hip and knee osteoarthritis in modelling the severities of right and left joints separately. Methodology/Principal Findings We developed a discrete-event simulation model that follows up the individuals with osteoarthritis over their lifetimes. The model defines separate attributes for right and left joints and accounts for several repeat replacements. The Australian population with osteoarthritis who were 40 years of age or older in 2003 were followed up until extinct. Intervention effects were modelled by means of disability-adjusted life-years (DALYs) averted. Both hip and knee replacements are highly cost effective (AUD 5,000 per DALY and AUD 12,000 per DALY respectively) under an AUD 50,000/DALY threshold level. The exclusion of cost offsets, and inclusion of future unrelated health care costs in extended years of life, did not change the findings that the interventions are cost-effective (AUD 17,000 per DALY and AUD 26,000 per DALY respectively). However, there was a substantial difference between hip and knee replacements where surgeries administered for hips were more cost-effective than for knees. Conclusions/Significance Both hip and knee replacements are cost-effective interventions to improve the quality of life of people with osteoarthritis. It was also shown that the dual nature of hip and knee OA should be taken into account to provide more accurate estimation on the cost-effectiveness of hip and knee replacements. PMID:21966520

  20. JOURNEY II XR Safety and Effectiveness PMCF

    ClinicalTrials.gov

    2018-04-19

    Rheumatoid Vasculitis With Rheumatoid Arthritis of Knee; Unilateral Post-Traumatic Osteoarthritis of Knee; Knee Osteoarthritis; Degenerative Arthritis Peripheral Joint; Failed Osteotomies; Failed Unicompartmental Replacement

  1. How to define responders in osteoarthritis

    PubMed Central

    Cooper, Cyrus; Adachi, Jonathan D.; Bardin, Thomas; Berenbaum, Francis; Flamion, Bruno; Jonsson, Helgi; Kanis, John A.; Pelousse, Franz; Lems, Willem F.; Pelletier, Jean-Pierre; Martel-Pelletier, Johanne; Reiter, Susanne; Reginster, Jean-Yves; Rizzoli, René; Bruyère, Olivier

    2013-01-01

    Background Osteoarthritis is a clinical syndrome of failure of the joint accompanied by varying degrees of joint pain, functional limitation, and reduced quality of life due to deterioration of articular cartilage and involvement of other joint structures. Scope Regulatory agencies require relevant clinical benefit on symptoms and structure modification for registration of a new therapy as a disease-modifying osteoarthritis drug (DMOAD). An international Working Group of the European Society on Clinical and Economic Aspects of Osteoporosis and Osteoarthritis (ESCEO) and International Osteoporosis Foundation was convened to explore the current burden of osteoarthritis, review current regulatory guidelines for the conduct of clinical trials, and examine the concept of responder analyses for improving drug evaluation in osteoarthritis. Findings The ESCEO considers that the major challenges in DMOAD development are the absence of a precise definition of the disease, particularly in the early stages, and the lack of consensus on how to detect structural changes and link them to clinically meaningful endpoints. Responder criteria should help identify progression of disease and be clinically meaningful. The ideal criterion should be sensitive to change over time and should predict disease progression and outcomes such as joint replacement. Conclusion The ESCEO considers that, for knee osteoarthritis, clinical trial data indicate that radiographic joint space narrowing >0.5 mm over 2 or 3 years might be a reliable surrogate measure for total joint replacement. On-going research using techniques such as magnetic resonance imaging and biochemical markers may allow the identification of these patients earlier in the disease process. PMID:23557069

  2. Comparison of air exhausts for surgical body suits (space suits) and the potential for periprosthetic joint infection.

    PubMed

    Ling, F; Halabi, S; Jones, C

    2018-07-01

    Periprosthetic joint infection is a major complication of total joint replacement surgery and is associated with significant morbidity, mortality and financial burden. Surgical body suits (space suits), originally designed to reduce the incidence of infection, have paradoxically been implicated in increased periprosthetic joint infection rates recently. Air exhausted from space suits may contribute to this increased rate of periprosthetic joint infection. To investigate the flow of air exhausted from space suits commonly used in modern operating theatres. The exhaust airflow patterns of four commercially available space suit systems were compared using a fog machine and serial still photographs. The space suit systems tested all air exhausted into the operating room. The single fan systems with a standard surgical gown exhausted air laterally from the posterior gown fold at approximately the level of the surgical field. The single fan system with a dedicated zippered suit exhausted air at a level below the surgical field. The dual fan system exhausted air out of the top of the helmet at a level above the surgical field. Space suit systems currently in use in joint replacement surgery differ significantly from traditional body exhaust systems; rather than removing contaminated air from the operating environment, modern systems exhaust this air into the operating room, in some cases potentially towards the sterile instrument tray and the surgical field. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Applying the Hájek Approach in Formula-Based Variance Estimation. Research Report. ETS RR-17-24

    ERIC Educational Resources Information Center

    Qian, Jiahe

    2017-01-01

    The variance formula derived for a two-stage sampling design without replacement employs the joint inclusion probabilities in the first-stage selection of clusters. One of the difficulties encountered in data analysis is the lack of information about such joint inclusion probabilities. One way to solve this issue is by applying Hájek's…

  4. Photovoltaic Roofs

    NASA Technical Reports Server (NTRS)

    Drummond, R. W., Jr.; Shepard, N. F., Jr.

    1984-01-01

    Solar cells perform two functions: waterproofing roof and generating electricity. Sections through horizontal and slanting joints show overlapping modules sealed by L-section rubber strips and side-by-side modules sealed by P-section strips. Water seeping through seals of slanting joints drains along channels. Rooftop photovoltaic array used watertight south facing roof, replacing shingles, tar, and gravel. Concept reduces cost of residential solar-cell array.

  5. Haemophilia and joint disease: pathophysiology, evaluation, and management

    PubMed Central

    Knobe, Karin; Berntorp, Erik

    2011-01-01

    In patients with haemophilia, regular replacement therapy with clotting factor concentrates (prophylaxis) is effective in preventing recurrent bleeding episodes into joints and muscles. However, despite this success, intra-articular and intramuscular bleeding is still a major clinical manifestation of the disease. Bleeding most commonly occurs in the knees, elbows, and ankles, and is often evident from early childhood. The pathogenesis of haemophilic arthropathy is multifactorial, with changes occurring in the synovium, bone, cartilage, and blood vessels. Recurrent joint bleeding causes synovial proliferation and inflammation (haemophilic synovitis) that contribute to end-stage degeneration (haemophilic arthropathy); with pain and limitation of motion severely affecting patients’ quality of life. If joint bleeding is not treated adequately, it tends to recur, resulting in a vicious cycle that must be broken to prevent the development of chronic synovitis and degenerative arthritis. Effective prevention and management of haemophilic arthropathy includes the use of early, aggressive prophylaxis with factor replacement therapies, as well as elective procedures, including restorative physical therapy, analgesia, aspiration, synovectomy, and orthopaedic surgery. Optimal treatment of patients with haemophilia requires a multidisciplinary team comprising a haematologist, physiotherapist, orthopaedic practitioner, rehabilitation physician, occupational therapist, psychologist, social workers, and nurses. Journal of Comorbidity 2011;1:51–59 PMID:29090136

  6. Hip joint replacement using monofilament polypropylene surgical mesh: an animal model.

    PubMed

    Białecki, Jacek; Majchrzycki, Marian; Szymczak, Antoni; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof

    2014-01-01

    Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.

  7. Hemophilia A Pseudoaneurysm in a Patient with High Responding Inhibitors Complicating Total Knee Arthroplasty: Embolization: A Cost-Reducing Alternative to Medical Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kickuth, Ralph, E-mail: ralph.kickuth@insel.ch; Anderson, Suzanne; Peter-Salonen, Kristiina

    2006-12-15

    Joint hemorrhages are very common in patients with severe hemophilia. Inhibitors in patients with hemophilia are allo-antibodies that neutralize the activity of the clotting factor. After total knee replacement, rare intra-articular bleeding complications might occur that do not respond to clotting factor replacement. We report a 40-year-old male with severe hemophilia A and high responding inhibitors presenting with recurrent knee joint hemorrhage after bilateral knee prosthetic surgery despite adequate clotting factor treatment. There were two episodes of marked postoperative hemarthrosis requiring extensive use of subsititution therapy. Eleven days postoperatively, there was further hemorrhage into the right knee. Digital subtraction angiographymore » diagnosed a complicating pseudoaneurysm of the inferior lateral geniculate artery and embolization was successfully performed. Because clotting factor replacement therapy has proved to be excessively expensive and prolonged, especially in patients with inhibitors, we recommend the use of cost-effective early angiographic embolization.« less

  8. [Efficacy of health education on patients with hip replacement based on the Internet].

    PubMed

    Zhou, Yang; Yang, Tubao; Li, Yinglan; Yu, Jie; Zeng, Biyun

    2015-03-01

    To evaluate the efficacy of health education on patients with hip replacement based on the Internet, and to establish a new health education model through modern technology. A total of 300 patients with hip replacement from March to August, 2015 were enrolled in this study. The participants were divided into a control group and an experimental group according to months surgeries performed. Traditional education was applied in the control group while the multimedia source material plus the Internet platform of Joint Registration System were applied in the experimental group. Levels of anxiety, degree of satisfaction, and postoperative complications were analyzed. The levels of knowledge, attitude and behavior compliance in the patients of the experimental group were significantly improved, while the levels of postoperative anxiety were decreased compared with those in the control group (P<0.05). Education based on the Internet platform of Joint Registration System and the computer video could improve patients' knowledge, attitude, and behavior, which is worthy of clinical spread.

  9. Extravehicular activity compatibility evaluation of developmental hardware for assembly and repair of precision reflectors

    NASA Technical Reports Server (NTRS)

    Heard, Walter L., Jr.; Lake, Mark S.; Bush, Harold G.; Jensen, J. Kermit; Phelps, James E.; Wallsom, Richard E.

    1992-01-01

    This report presents results of tests performed in neutral buoyancy by two pressure-suited test subjects to simulate Extravehicular Activity (EVA) tasks associated with the on-orbit construction and repair of a precision reflector spacecraft. Two complete neutral buoyancy assemblies of the test article (tetrahedral truss with three attached reflector panels) were performed. Truss joint hardware, two different panel attachment hardware concepts, and a panel replacement tool were evaluated. The test subjects found the operation and size of the truss joint hardware to be acceptable. Both panel attachment concepts were found to be EVA compatible, although one concept was judged by the test subjects to be considerably easier to operate. The average time to install a panel from a position within arm's reach of the test subjects was 1 min 14 sec. The panel replacement tool was used successfully to demonstrate the removal and replacement of a damaged reflector panel in 10 min 25 sec.

  10. Effects of aging treatment and heat input on the microstructures and mechanical properties of TIG-welded 6061-T6 alloy joints

    NASA Astrophysics Data System (ADS)

    Peng, Dong; Shen, Jun; Tang, Qin; Wu, Cui-ping; Zhou, Yan-bing

    2013-03-01

    Aging treatment and various heat input conditions were adopted to investigate the microstructural evolution and mechanical properties of TIG welded 6061-T6 alloy joints by microstructural observations, microhardness tests, and tensile tests. With an increase in heat input, the width of the heat-affected zone (HAZ) increases and grains in the fusion zone (FZ) coarsen. Moreover, the hardness of the HAZ decreases, whereas that of the FZ decreases initially and then increases with an increase in heat input. Low heat input results in the low ultimate tensile strength of the welded joints due to the presence of partial penetrations and pores in the welded joints. After a simple artificial aging treatment at 175°C for 8 h, the microstructure of the welded joints changes slightly. The mechanical properties of the welded joints enhance significantly after the aging process as few precipitates distribute in the welded seam.

  11. Influence of artificial shock absorbers on human gait.

    PubMed

    Voloshin, A; Wosk, J

    1981-10-01

    The effect of artificial shock absorbers on the human gait and the technique for its quantitative evaluation have been studied. The results obtained have shown that viscoelastic inserts reduced the amplitude of the incoming shock waves bearing upon the musculoskeletal system as a result of the heel strike, by 42 percent (mean value). Conservative treatment, using such inserts for patients with different clinical symptoms of degenerative joint diseases, has shown excellent results. Seventy-eight percent of the clinical symptoms disappeared, while satisfactory improvement was reported in 17 percent of the subjects.

  12. A model-based approach to stabilizing crutch supported paraplegic standing by artificial hip joint stiffness.

    PubMed

    van der Spek, Jaap H; Veltink, Peter H; Hermens, Hermie J; Koopman, Bart F J M; Boom, Herman B K

    2003-12-01

    The prerequisites for stable crutch supported standing were analyzed in this paper. For this purpose, a biomechanical model of crutch supported paraplegic stance was developed assuming the patient was standing with extended knees. When using crutches during stance, the crutches will put a position constraint on the shoulder, thus reducing the number of degrees of freedom. Additional hip-joint stiffness was applied to stabilize the hip joint and, therefore, to stabilize stance. The required hip-joint stiffness for changing crutch placement and hip-joint offset angle was studied under static and dynamic conditions. Modeling results indicate that, by using additional hip-joint stiffness, stable crutch supported paraplegic standing can be achieved, both under static as well as dynamic situations. The static equilibrium postures and the stability under perturbations were calculated to be dependent on crutch placement and stiffness applied. However, postures in which the hip joint was in extension (C postures) appeared to the most stable postures. Applying at least 60 N x m/rad hip-joint stiffness gave stable equilibrium postures in all cases. Choosing appropriate hip-joint offset angles, the static equilibrium postures changed to more erect postures, without causing instability or excessive arm forces to occur.

  13. Total Knee Replacement

    PubMed Central

    2005-01-01

    Executive Summary Objective The aim of this review was to assess the effectiveness, in terms of pain reduction and functional improvement, and costing of total knee replacement (TKR) for people with osteoarthritis for whom less invasive treatments (such as physiotherapy, analgesics, anti-inflammatory drugs, intra-articular steroids, hyaluronic acids, and arthroscopic surgery) have failed. Clinical Need Osteoarthritis affects an estimated 10% to 12% of Canadian adults. The therapeutic goals of osteoarthritis treatment are to improve joint mobility and reduce pain. Stepwise treatment options include exercise, weight loss, physiotherapy, analgesics, anti-inflammatory drugs, intra-articular steroids and hyaluronic acids, arthroscopic surgery, and, in severe cases, total joint replacement with follow-up rehabilitation. These treatments are delivered by a range of health care professionals, including physiotherapists, occupational therapists, family physicians, internists, rheumatologists, and orthopedic surgeons. TKR is an end-of-line treatment for patients with severe pain and functional limitations. More women than men undergo knee replacement, and most patients are between 55 and 84 years old. The Technology TKR is a surgical procedure in which an artificial joint or prosthesis replaces a damaged knee joint. The primary indication for TKR is pain, followed by functional limitation. Usually, a person’s daily activities must be substantially affected by pain and functional limitations for him or her to be considered a candidate for TKR. There are 3 different types of knee replacement prostheses. Non-constrained prostheses use the patient’s ligaments and muscles to provide the stability for the prosthesis. Semi-constrained prostheses provide some stability for the knee and do not rely entirely on the patient’s ligaments and muscles to provide the stability. Constrained prostheses are for patients whose ligaments and muscles are not able to provide stability for the knee prosthesis. The most common risks and complications associated with TKR are deep venous thrombosis, infection, stiffness, loosening, and osteolysis. To prevent deep venous thrombosis, patients are treated with heparin prophylactically and/or given support stockings to wear. Patients are also given antibiotics for 24 hours after surgery to minimize the risk of infection. Stiffness is another associated complication. In most patients, it can be avoided by keeping the knee moving in the days and weeks following surgery. The National Institutes of Health in the United States concluded that the indications for TKR should include the following: radiological evidence of joint damage, moderate to severe persistent pain that is not adequately relieved by nonsurgical management, and clinically significant functional limitation resulting in diminished quality of life. Review Strategy In March 2005, the following databases were searched: Cochrane Library International Agency for Health Technology Assessment (first quarter 2005), Cochrane Database of Systematic Reviews (first quarter 2005), Cochrane Central Register of Controlled Trials (first quarter 2005), MEDLINE (1966 to March 2005), MEDLINE In-Process and Other Non-indexed Citations (1966 to March 14, 2005), and EMBASE (1980 to 2005 week 9). The Medical Advisory Secretariat also searched Medscape on the Internet for recent reports on trials that were unpublished but that were presented at international conferences. In addition, the Web site Current Controlled Trials (www.controlled-trials.com) was searched for ongoing trials investigating TKR or unicompartmental knee replacement. No studies were identified that compared TKR to an alternative treatment. Several studies have been reported that compare preoperative measurement scores on targeted measures of functioning and pain to postoperative measurement scores in patients undergoing various TKR procedures. In order for the Medical Advisory Secretariat to measure the effectiveness of TKR and to compare the effectiveness of TKR across studies, effect sizes were calculated in studies that reported the standard deviations of the preoperative and postoperative measurement scores. Percent change was also calculated. For this review, a 20% improvement in outcome score was defined as the minimal clinically important difference. Summary of Findings Overall, patients who undergo TKR surgery for osteoarthritis have substantial improvements in terms of reduction of pain and improvement of function. A comparison of the mean effect score and the percent change in 19 studies that reported preoperative and postoperative outcome scores for patients who had TKR showed that the procedure is effective. The 19 studies included patients of various ages and used a variety of prostheses and techniques to implant the device. TKR was effective in all of the studies. The revision rates ranged from 0% to 13% in the studies that reported at least 5 years of follow-up. As for the factors that predict TKR outcomes, a variety of factors have been evaluated, including obesity, age, gender, prosthesis design, and surgical techniques; however, none of these have been shown to predict outcomes (pain or function) consistently across studies. However, the regression analyses identified accounted for only 12% to 27% of the variance, indicating that over 70% of the variance in the outcomes of TKR is unexplained. In terms of the timing of TKR surgery, 2 studies found that the severity of osteoarthritis does not predict outcome, but 1 study was found that higher functioning patients had significantly less pain and better function up to 2 years after surgery compared with lower functioning patients. It is important to note that the patients in the low and high function groups were evenly matched on comorbid conditions. Unicompartmental knee replacement surgery seems to be as effective as TKR surgery for people who meet the indications for it. This is a subset of people who have osteoarthritis of the knee, because for unicompartmental knee replacement to be indicated, only 1 (usually the medial) compartment of the knee can be affected. Patients who undergo this kind of surgery seem to have shorter hospital stays and faster recovery times than do patients who have TKR surgery. Conclusion There is substantial evidence to indicate that TKR effectively reduces pain and improves function. PMID:23074478

  14. [Endoprosthesis Infections - Guidelines for Antibiotic Therapy Common Guidelines of the Czech Society for Orthopaedics and Traumatology and the Society for Infectious Diseases of the Czech Medical Association of J. E. Purkyně].

    PubMed

    Musil, D; Balejová, M; Horníková, M; Chrdle, A; Mallátová, N; Nyč, O; Chmelík, V; Gallo, J; Jahoda, D; Stehlík, J

    2017-01-01

    PURPOSE OF THE STUDY This study aims to articulate regional guidelines for curative and suppressive antibiotic therapy of total joint replacement infections. MATERIAL AND METHODS When developing the standard, used as source materials were the published foreign guidelines for antibiotic therapy of prosthetic joint infections, the analysis of resistance of bacterial strains conducted in the Hospital in České Budějovice, a.s. and the assessment of strain resistance for the Czech Republic published by the European Antimicrobial Resistance Surveillance Network (EARS-Net). Considered was also the availability of individual antibiotics in the Czech Republic and restricted prescription according to the Summary of Product Characteristics as specified in the State Institute for Drug Control marketing authorisation. The expert group composed of orthopaedists, microbiologists and infectious disease specialists elaborated the basic antibiotic guideline for choosing an appropriate antibiotic/antifungal drug based on the usual susceptibility, its dose and dosage interval for initial and continuation therapy. The comments of individual specialists were gradually incorporated therein and in case of doubts majority rule was applied. The drafted document was sent for peer reviews to clinical orthopaedic, infectious disease and microbiological centres, whose comments were also incorporated and the finalised document was submitted for evaluation to specialised medical societies. RESULTS The outcome is the submitted guideline for antibiotic curative and suppressive therapy suitable for managing the prosthetic joint infections, which was approved by the committee of the Czech Society for Orthopaedics and Traumatology andthe Society for Infectious Diseases of the Czech Medical Association of J. E. Purkyně. DISCUSION Curative therapy of total joint replacement infections consists primarily in surgical treatment and has to be accompanied by adequate antibiotic therapy administered initially intravenously and later orally over a sufficient period of time. Bearing in mind the wide spectrum of pathogens that can cause infections of a joint replacement and their capacity to form a biofilm on foreign materials, the correct choice of an antibiotic, its dose and dosage interval are essential for successful treatment. Such standard should respect regional availability of antibiotics, regional pathogen resistance/susceptibility and ensure the achievement of sufficiently high concentrations at the requested location including anti-biofilm activity. CONCLUSIONS The submitted guideline is not the only treatment option for joint total replacement infections, but it makes the decisionmaking easier when treating these complications in the form of infections. The final choice of an antibiotic, its dose and duration of therapy shall be based on a critical assessment of results of microbiological (blood culture and molecular genetic) tests and reflect the patient s clinical condition. Since these are multidisciplinary issues, we consider useful for this guideline to be commented upon and approved by the committee of both the Society for Orthopaedics and Infectious Diseases so that it can become the starting point for treatment. Key words: total joint replacement infection, TEP, ATB, antibiotic therapy, consensus meeting, guideline.

  15. Prehensile control of a hand prosthesis by a microcontroller.

    PubMed

    Chappell, P H; Kyberd, P J

    1991-09-01

    The functional replacement of a natural hand and wrist is usually achieved by a split hook or an electrically powered and myoelectrically controlled artificial hand with one degree of freedom. In contrast to the commercial devices, this paper describes an experimental hand with four electric motors, nineteen sensors, and control algorithms which are written for a microcontroller. The hand significantly improves the prehension capabilities of an artificial device and leads to a design which is easily controlled by a user as it mimics the control system of the natural hand.

  16. Contemporary issues in the regulation of artificial reproduction and embryology in the UK.

    PubMed

    Garwood-Gowers, Austen

    2004-01-01

    The Human Fertilisation and Embryology Act 1990 was one of the most comprehensive and flexible vehicles for regulation of artificial reproduction and embryology of its area. However, its serviceability has recently been brought into question by both the materialisation of unforeseen dilemmas and the response of legal actors to these dilemma's which has often been ethically and democratically deficient. Nowhere is this better demonstrated than in the reproach of the regulatory authority and judiciary to the use pre-implantation genetic diagnosis and cloning by cell nuclear replacement.

  17. Corrosion in artificial saliva of a Ni-Cr-based dental alloy joined by TIG welding and conventional brazing.

    PubMed

    Matos, Irma C; Bastos, Ivan N; Diniz, Marília G; de Miranda, Mauro S

    2015-08-01

    Fixed prosthesis and partial dental prosthesis frameworks are usually made from welded Ni-Cr-based alloys. These structures can corrode in saliva and have to be investigated to establish their safety. The purpose of this study was to evaluate the corrosion behavior of joints joined by tungsten inert gas (TIG) welding and conventional brazing in specimens made of commercial Ni-Cr alloy in Fusayama artificial saliva at 37°C (pH 2.5 and 5.5). Eighteen Ni-Cr base metal specimens were cast and welded by brazing or tungsten inert gas methods. The specimens were divided into 3 groups (base metal, 2 welded specimens), and the composition and microstructure were qualitatively evaluated. The results of potential corrosion and corrosion current density were analyzed with a 1-way analysis of variance and the Tukey test for pairwise comparisons (α=.05). Base metal and tungsten inert gas welded material showed equivalent results in electrochemical corrosion tests, while the air-torched specimens exhibited low corrosion resistance. The performance was worst at pH 2.5. These results suggest that tungsten inert gas is a suitable welding process for use in dentistry, because the final microstructure does not reduce the corrosion resistance in artificial saliva at 37°C, even in a corrosion-testing medium that facilitates galvanic corrosion processes. Moreover, the corrosion current density of brazed Ni-Cr alloy joints was significantly higher (P<.001) than the base metal and tungsten inert gas welded joints. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Biofluid lubrication for artificial joints

    NASA Astrophysics Data System (ADS)

    Pendleton, Alice Mae

    This research investigated biofluid lubrication related to artificial joints using tribological and rheological approaches. Biofluids studied here represent two categories of fluids, base fluids and nanostructured biofluids. Base fluids were studied through comparison of synthetic fluids (simulated body fluid and hyaluronic acid) as well as natural biofluids (from dogs, horses, and humans) in terms of viscosity and fluid shear stress. The nano-structured biofluids were formed using molecules having well-defined shapes. Understanding nano-structured biofluids leads to new ways of design and synthesis of biofluids that are beneficial for artificial joint performance. Experimental approaches were utilized in the present research. This includes basic analysis of biofluids' property, such as viscosity, fluid shear stress, and shear rate using rheological experiments. Tribological investigation and surface characterization were conducted in order to understand effects of molecular and nanostructures on fluid lubrication. Workpiece surface structure and wear mechanisms were investigated using a scanning electron microscope and a transmission electron microscope. The surface topography was examined using a profilometer. The results demonstrated that with the adding of solid additives, such as crown ether or fullerene acted as rough as the other solids in the 3-body wear systems. In addition, the fullerene supplied low friction and low wear, which designates the lubrication purpose of this particular particle system. This dissertation is constructed of six chapters. The first chapter is an introduction to body fluids, as mentioned earlier. After Chapter II, it examines the motivation and approach of the present research, Chapter III discusses the experimental approaches, including materials, experimental setup, and conditions. In Chapter IV, lubrication properties of various fluids are discussed. The tribological properties and performance nanostructured biofluids are discussed in Chapter V, followed by summary and conclusions in Chapter VI.

  19. Knee Joint Loads and Surrounding Muscle Forces during Stair Ascent in Patients with Total Knee Replacement

    PubMed Central

    Rasnick, Robert; Standifird, Tyler; Reinbolt, Jeffrey A.; Cates, Harold E.

    2016-01-01

    Total knee replacement (TKR) is commonly used to correct end-stage knee osteoarthritis. Unfortunately, difficulty with stair climbing often persists and prolongs the challenges of TKR patents. Complete understanding of loading at the knee is of great interest in order to aid patient populations, implant manufacturers, rehabilitation, and future healthcare research. Musculoskeletal modeling and simulation approximates joint loading and corresponding muscle forces during a movement. The purpose of this study was to determine if knee joint loadings following TKR are recovered to the level of healthy individuals, and determine the differences in muscle forces causing those loadings. Data from five healthy and five TKR patients were selected for musculoskeletal simulation. Variables of interest included knee joint reaction forces (JRF) and the corresponding muscle forces. A paired samples t-test was used to detect differences between groups for each variable of interest (p<0.05). No differences were observed for peak joint compressive forces between groups. Some muscle force compensatory strategies appear to be present in both the loading and push-off phases. Evidence from knee extension moment and muscle forces during the loading response phase indicates the presence of deficits in TKR in quadriceps muscle force production during stair ascent. This result combined with greater flexor muscle forces resulted in similar compressive JRF during loading response between groups. PMID:27258086

  20. 77 FR 73279 - Airworthiness Directives; Saab AB, Saab Aerosystems Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-10

    ... AD was prompted by reports of stall events during icing conditions where the natural stall warning (buffet) was not identified. This AD requires replacing the stall warning computer (SWC) with a new SWC, which provides an artificial stall [[Page 73280

  1. Achieving Consensus on Total Joint Replacement Trial Outcome Reporting Using the OMERACT Filter: Endorsement of the Final Core Domain Set for Total Hip and Total Knee Replacement Trials for Endstage Arthritis.

    PubMed

    Singh, Jasvinder A; Dowsey, Michelle M; Dohm, Michael; Goodman, Susan M; Leong, Amye L; Scholte Voshaar, Marieke M J H; Choong, Peter F

    2017-11-01

    Discussion and endorsement of the OMERACT total joint replacement (TJR) core domain set for total hip replacement (THR) and total knee replacement (TKR) for endstage arthritis; and next steps for selection of instruments. The OMERACT TJR working group met at the 2016 meeting at Whistler, British Columbia, Canada. We summarized the previous systematic reviews, the preliminary OMERACT TJR core domain set and results from previous surveys. We discussed preliminary core domains for TJR clinical trials, made modifications, and identified challenges with domain measurement. Working group participants (n = 26) reviewed, clarified, and endorsed each of the inner and middle circle domains and added a range of motion domain to the research agenda. TJR were limited to THR and TKR but included all endstage hip and knee arthritis refractory to medical treatment. Participants overwhelmingly endorsed identification and evaluation of top instruments mapping to the core domains (100%) and use of subscales of validated multidimensional instruments to measure core domains for the TJR clinical trial core measurement set (92%). An OMERACT core domain set for hip/knee TJR trials has been defined and we are selecting instruments to develop the TJR clinical trial core measurement set to serve as a common foundation for harmonizing measures in TJR clinical trials.

  2. Meniscal tears, repairs and replacement: their relevance to osteoarthritis of the knee.

    PubMed

    McDermott, Ian

    2011-04-01

    The menisci of the knee are important load sharers and shock absorbers in the joint. Meniscal tears are common, and whenever possible meniscal tears should be surgically repaired. Meniscectomy leads to a significant increased risk of osteoarthritis, and various options now exist for replacing missing menisci, including the use of meniscal scaffolds or the replacement of the entire meniscus by meniscal allograft transplantation. The field of meniscal surgery continues to develop apace, and the future may lie in growing new menisci by tissue engineering techniques.

  3. Taking care of your new hip joint

    MedlinePlus

    Hip arthroplasty - precautions; Hip replacement - precautions; Osteoarthritis - hip; Osteoarthritis - knee ... Saunders; 2015:chap 61. Harkess JW, Crockarell JR. Arthroplasty of the hip. In: Azar FM, Beaty JH, ...

  4. High-throughput characterization for solar fuels materials discovery

    NASA Astrophysics Data System (ADS)

    Mitrovic, Slobodan; Becerra, Natalie; Cornell, Earl; Guevarra, Dan; Haber, Joel; Jin, Jian; Jones, Ryan; Kan, Kevin; Marcin, Martin; Newhouse, Paul; Soedarmadji, Edwin; Suram, Santosh; Xiang, Chengxiang; Gregoire, John; High-Throughput Experimentation Team

    2014-03-01

    In this talk I will present the status of the High-Throughput Experimentation (HTE) project of the Joint Center for Artificial Photosynthesis (JCAP). JCAP is an Energy Innovation Hub of the U.S. Department of Energy with a mandate to deliver a solar fuel generator based on an integrated photoelectrochemical cell (PEC). However, efficient and commercially viable catalysts or light absorbers for the PEC do not exist. The mission of HTE is to provide the accelerated discovery through combinatorial synthesis and rapid screening of material properties. The HTE pipeline also features high-throughput material characterization using x-ray diffraction and x-ray photoemission spectroscopy (XPS). In this talk I present the currently operating pipeline and focus on our combinatorial XPS efforts to build the largest free database of spectra from mixed-metal oxides, nitrides, sulfides and alloys. This work was performed at Joint Center for Artificial Photosynthesis, a DOE Energy Innovation Hub, supported through the Office of Science of the U.S. Department of Energy under Award No. DE-SC0004993.

  5. Reconstructing for joint angles on the shoulder and elbow from non-invasive electroencephalographic signals through electromyography

    PubMed Central

    Choi, Kyuwan

    2013-01-01

    In this study, first the cortical activities over 2240 vertexes on the brain were estimated from 64 channels electroencephalography (EEG) signals using the Hierarchical Bayesian estimation while 5 subjects did continuous arm reaching movements. From the estimated cortical activities, a sparse linear regression method selected only useful features in reconstructing the electromyography (EMG) signals and estimated the EMG signals of 9 arm muscles. Then, a modular artificial neural network was used to estimate four joint angles from the estimated EMG signals of 9 muscles: one for movement control and the other for posture control. The estimated joint angles using this method have the correlation coefficient (CC) of 0.807 (±0.10) and the normalized root-mean-square error (nRMSE) of 0.176 (±0.29) with the actual joint angles. PMID:24167469

  6. Does the person's context influence engagement in life activities following primary knee replacement? Results from a Canadian prospective cohort study.

    PubMed

    Davis, Aileen M; Venkataramanan, Viji; Bytautas-Sillanpää, Jessica; Perruccio, Anthony V; Wong, Rosalind; Carlesso, Lisa; Webster, Fiona

    2017-08-18

    The impact of the context of a person's life on recovery from surgical interventions is not well understood. This study evaluated if people's social, environmental and biomedical context was associated with change in frequency in engagement in life activities after total knee replacement (TKR). 418 people aged 30+ years who had TKR were followed presurgery to 1 year postsurgery. The outcome was change in frequency in engagement in life activities measured by the Late Life Disability Index (LLDI). Predictor variables of interest evaluated in multivariable linear regression analysis were positive and negative life events (Life Experiences Survey), development of a new comorbidity, another joint replacement and complications after TKR surgery. Mean age was 65 years, 36% were male; 22% and 21% had no comorbidity presurgery and postsurgery. Presurgery LLDI frequency was 69.6 (±11.4) and the mean change was 6.1 (±10.2). Thirty-four per cent and 65% reported at least one positive or negative life event. Seven per cent developed hypertension, 6% cardiovascular disease, 2% lung disease and 2% diabetes. Eleven per cent had a complication and 9% another hip or knee replaced. Smaller changes in LLDI frequency were associated with more negative life events (beta=-0.56; 95% CI -0.92 to-0.18) and complications (beta=-4.01; 95% CI -6.63 to -1.38) after adjusting for age, sex, education, body mass index, comorbidities presurgery, number of symptomatic joints and knee-specific pain and function, LLDI limitations and depression. A new comorbidity or another joint replacement was not associated with outcome in unadjusted or adjusted analysis. Multifaceted life experiences shape the context of peoples' lives impacting their engagement in activities important for healthy living post-TKR. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Joint Tactical Radio System Handheld, Manpack, and Small Form Fit Radios (JTRS HMS)

    DTIC Science & Technology

    2013-12-01

    requisitions through the Standard Army Supply System ( SASS ). All radios procured under the Full Rate Production (FRP) phase that become unserviceable...will be turned-in to TYAD through the SASS . Radios will be returned to the original equipment manufacturer vendor for warranty repair, or replacement...procure sustainment spares to replace unserviceable radios and ancillary items requisitioned through SASS , operations, maintenance, training

  8. The volume of the human knee joint.

    PubMed

    Matziolis, Georg; Roehner, Eric; Windisch, Christoph; Wagner, Andreas

    2015-10-01

    Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date. Therefore, the objective of this study was to determine knee joint volume and whether or not it is dependent on sex or body height. Sixty-one consecutive patients (joints) who were due to undergo endoprosthetic joint replacement were enrolled in this prospective study. During the operation, the joint volume was determined by injecting saline solution until a pressure of 200 mmHg was achieved in the joint. The average volume of all knee joints was 131 ± 53 (40-290) ml. The volume was not found to be dependent on sex, but it was dependent on the patients' height (R = 0.312, p = 0.014). This enabled an estimation of the joint volume according to V = 1.6 height - 135. The considerable inter-individual variance of the knee joint volume would suggest that it should be determined or at least estimated according to body height if the joint volume has consequences for the diagnostics or therapy of knee disorders.

  9. Biotribology of Cartilage Wear in Knee and Hip Joints Review of Recent Developments

    NASA Astrophysics Data System (ADS)

    Gulsen, Akdogan; Merve, Goncu; Meltem, Parlak

    2018-01-01

    Nowadays, the problem of wear in the knee and hip joints is an important issue that concerns many people and still requires new solutions. In recent years, researchers dealing with knee and hip articular cartilage erosion continue to investigate the subject in terms of biotribology. In this study, recent developments and studies in this relevant area are been examined. By using the basic principles of tribology, useful new methods that can be used in the field of biotribology can be produced. Artificial joints designed using various materials such as metals, ceramics, polymers and composites are still being studied. New studies in this area will affect the development of implant technology. Different alloys or composites are currently being tested for new implant designs. Moving implants with a risk of wear are tested in laboratory conditions in simulator devices before they are used in the human body. Major topics such as nanotechnology, tissue engineering, orthopedics, tribology, biotribology, lubrication, organ transplantation and artificial organs, which are still important today, will be useful in the search for finding suitable solutions in the future in biotribological studies. This review article aims to provide an overview of in-vitro studies at the theoretical and laboratory conditions that must be performed prior to clinical investigation.

  10. A small punch test technique for characterizing the elastic modulus and fracture behavior of PMMA bone cement used in total joint replacement.

    PubMed

    Giddings, V L; Kurtz, S M; Jewett, C W; Foulds, J R; Edidin, A A

    2001-07-01

    Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.

  11. Forced-air warming and ultra-clean ventilation do not mix: an investigation of theatre ventilation, patient warming and joint replacement infection in orthopaedics.

    PubMed

    McGovern, P D; Albrecht, M; Belani, K G; Nachtsheim, C; Partington, P F; Carluke, I; Reed, M R

    2011-11-01

    We investigated the capacity of patient warming devices to disrupt the ultra-clean airflow system. We compared the effects of two patient warming technologies, forced-air and conductive fabric, on operating theatre ventilation during simulated hip replacement and lumbar spinal procedures using a mannequin as a patient. Infection data were reviewed to determine whether joint infection rates were associated with the type of patient warming device that was used. Neutral-buoyancy detergent bubbles were released adjacent to the mannequin's head and at floor level to assess the movement of non-sterile air into the clean airflow over the surgical site. During simulated hip replacement, bubble counts over the surgical site were greater for forced-air than for conductive fabric warming when the anaesthesia/surgery drape was laid down (p = 0.010) and at half-height (p < 0.001). For lumbar surgery, forced-air warming generated convection currents that mobilised floor air into the surgical site area. Conductive fabric warming had no such effect. A significant increase in deep joint infection, as demonstrated by an elevated infection odds ratio (3.8, p = 0.024), was identified during a period when forced-air warming was used compared to a period when conductive fabric warming was used. Air-free warming is, therefore, recommended over forced-air warming for orthopaedic procedures.

  12. Meniscus tear surgery and meniscus replacement

    PubMed Central

    Vaquero, Javier; Forriol, Francisco

    2016-01-01

    Summary Objective the menisci are easily injured and difficult to repair. The aim of this study was to analyze the current state of meniscal surgery aimed at preserving morphology and conserving the biomechanics of the knee to prevent joint degeneration. Methodology a search of the electronic medical literature database Medline was conducted, from http://www.ncbi.nlm.nih.gov/pubmed. The search was not limited by language. Candidate articles were identified by searching for those that included the keywords meniscus, surgery, suture, implant, allograft. The limits were included for clinical research and clinical trials. Basic research was not included. The studies selected were evaluated and classified in three different categories: basic science, reconstruction (suture and meniscectomy) and implants (scaffolds and allograft). Results the consequences of meniscectomy performed at a young age can lead to a joint cartilage degeneration twenty years later. There are few surgical options for the repair of meniscal injuries in order both to preserve the meniscus and to ensure the long term survival of the knee joint, meniscectomy, repair, suturing the tear, or reconstruction, when a meniscal allograft or synthetic substitute is used to replace the meniscus, but the biomechanical properties of the native meniscus are not reproduced entirely by the scaffolds that exist today. Conclusion therapies that successfully repair or replace the meniscus are therefore likely to prevent or delay osteoarthritis progression. PMID:27331034

  13. What is the impact of a clinically related readmission measure on the assessment of hospital performance?

    PubMed

    Khouri, Roger K; Hou, Hechuan; Dhir, Apoorv; Andino, Juan J; Dupree, James M; Miller, David C; Ellimoottil, Chad

    2017-11-28

    The Hospital Readmission Reduction Program (HRRP) penalizes hospitals for high all-cause unplanned readmission rates. Many have expressed concern that hospitals serving patient populations with more comorbidities, lower incomes, and worse self-reported health status may be disproportionately penalized by readmissions that are not clinically related to the index admission. The impact of including clinically unrelated readmissions on hospital performance is largely unknown. We sought to determine if a clinically related readmission measure would significantly alter the assessment of hospital performance. We analyzed Medicare claims for beneficiaries in Michigan admitted for pneumonia and joint replacement from 2011 to 2013. We compared each hospital's 30-day readmission rate using specifications from the HRRP's all-cause unplanned readmission measure to values calculated using a clinically related readmission measure. We found that the mean 30-day readmission rates were lower when calculated using the clinically related readmission measure (joint replacement: all-cause 5.8%, clinically related 4.9%, p < 0.001; pneumonia: all cause 12.5%, clinically related 11.3%, p < 0.001)). The correlation of hospital ranks using both methods was strong (joint replacement: 0.95 (p < 0.001), pneumonia: 0.90 (p < 0.001)). Our findings suggest that, while greater specificity may be achieved with a clinically related measure, clinically unrelated readmissions may not impact hospital performance in the HRRP.

  14. Knee joint replacement - slideshow

    MedlinePlus

    ... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...

  15. Experimental validation of finite element modelling of a modular metal-on-polyethylene total hip replacement.

    PubMed

    Hua, Xijin; Wang, Ling; Al-Hajjar, Mazen; Jin, Zhongmin; Wilcox, Ruth K; Fisher, John

    2014-07-01

    Finite element models are becoming increasingly useful tools to conduct parametric analysis, design optimisation and pre-clinical testing for hip joint replacements. However, the verification of the finite element model is critically important. The purposes of this study were to develop a three-dimensional anatomic finite element model for a modular metal-on-polyethylene total hip replacement for predicting its contact mechanics and to conduct experimental validation for a simple finite element model which was simplified from the anatomic finite element model. An anatomic modular metal-on-polyethylene total hip replacement model (anatomic model) was first developed and then simplified with reasonable accuracy to a simple modular total hip replacement model (simplified model) for validation. The contact areas on the articulating surface of three polyethylene liners of modular metal-on-polyethylene total hip replacement bearings with different clearances were measured experimentally in the Leeds ProSim hip joint simulator under a series of loading conditions and different cup inclination angles. The contact areas predicted from the simplified model were then compared with that measured experimentally under the same conditions. The results showed that the simplification made for the anatomic model did not change the predictions of contact mechanics of the modular metal-on-polyethylene total hip replacement substantially (less than 12% for contact stresses and contact areas). Good agreements of contact areas between the finite element predictions from the simplified model and experimental measurements were obtained, with maximum difference of 14% across all conditions considered. This indicated that the simplification and assumptions made in the anatomic model were reasonable and the finite element predictions from the simplified model were valid. © IMechE 2014.

  16. [Contact allergic gastritis : Rare manifestation of a metal allergy].

    PubMed

    Pföhler, C; Vogt, T; Müller, C S L

    2016-05-01

    Only a few cases of contact allergic gastritis in patients with nickel allergy have been reported in the literature. We report a case of probable contact-allergic gastritis in a 46-year-old woman. Clinical examination revealed lichenoid mucosal lesions of the gums adjacent to a bridge and crowns that had been implanted several weeks previously. Since implantation, the patient suffered from gastrointestinal complaints including stomach pain. Gastroscopy and histological investigation of stomach biopsies showed eosinophilic gastritis. Patch testing done under the diagnosis of contact allergic stomatitis showed positive reactions to gold sodium thiosulphate, manganese (II) chloride, nickel (II) sulphate, palladium chloride, vanadium (III) chloride, zirconium (IV) chloride, and fragrances. The crowns and the bridge contained gold, palladium, and zirconium, hence they were replaced by titan-based dentition. Shortly after replacing the artificial dentition, all gastrointestinal symptoms resolved spontaneously without further treatment. Delayed-type allergy to components in the artificial dentition seem to have caused the gastritis.

  17. The total artificial heart for biventricular heart failure and beyond.

    PubMed

    Kasirajan, Vigneshwar; Tang, Daniel G; Katlaps, Gundars J; Shah, Keyur B

    2012-05-01

    Treatment options for late-stage biventricular heart failure are limited but include medical therapy with intravenous inotropes, biventricular assist devices (Bi-VADs) and the total artificial heart (TAH). In this manuscript, we review the indications, surgical techniques and outcomes for the TAH. The TAH offers biventricular replacement, rather than 'assistance', as the device is placed orthotopically after excision of the entire ventricular myocardium and all four native valves. In contrast to patients with Bi-VADs, patients with the TAH have no postoperative inotrope requirements, arrhythmias or inflow/outflow cannulae-related complications. Additionally, patients participate in rehabilitation early after device placement and the development of a portable drive may facilitate hospital discharge in the USA. Furthermore, total heart replacement may be ideal for heart failure associated with unique anatomical and mechanical complications. The TAH is an effective therapeutic option for the treatment of patients dying of heart failure who may not be suitable candidates for left ventricular assist devices.

  18. The Bright, Artificial Intelligence-Augmented Future of Neuroimaging Reading.

    PubMed

    Hainc, Nicolin; Federau, Christian; Stieltjes, Bram; Blatow, Maria; Bink, Andrea; Stippich, Christoph

    2017-01-01

    Radiologists are among the first physicians to be directly affected by advances in computer technology. Computers are already capable of analyzing medical imaging data, and with decades worth of digital information available for training, will an artificial intelligence (AI) one day signal the end of the human radiologist? With the ever increasing work load combined with the looming doctor shortage, radiologists will be pushed far beyond their current estimated 3 s allotted time-of-analysis per image; an AI with super-human capabilities might seem like a logical replacement. We feel, however, that AI will lead to an augmentation rather than a replacement of the radiologist. The AI will be relied upon to handle the tedious, time-consuming tasks of detecting and segmenting outliers while possibly generating new, unanticipated results that can then be used as sources of medical discovery. This will affect not only radiologists but all physicians and also researchers dealing with medical imaging. Therefore, we must embrace future technology and collaborate interdisciplinary to spearhead the next revolution in medicine.

  19. An electric artificial heart for clinical use.

    PubMed Central

    Pierce, W S; Rosenberg, G; Snyder, A J; Pae, W E; Donachy, J H; Waldhausen, J A

    1990-01-01

    Advances in microelectronics, high-strength magnets, and control system design now make replacement of the heart using an implantable, electrically powered pump feasible. The device described herein is a compact, dual pusher plate unit with valved polyurethane sac-type ventricles positioned at either end. The power unit consists of a small, brushless direct current motor and a motion translator. A microprocessor control system is used to regulate heart beat rate and provide left-right output balance. Bench studies lasting for as long as 1 year have been performed. Heart replacement with the electric heart has been performed in 18 calves since 1984. The longest survivor lived for more than 7 months. Among the causes of termination were component failure, thromboembolic complications, and bleeding. No major problem has been identified that precludes prolonged use of the electric heart. In the future the patient with end-stage heart disease will have an electric artificial heart as one therapeutic option. Images Figs. 1A and 1B. Fig. 3. Fig. 5. PMID:2396885

  20. FAA/NASA Joint University Program for Air Transportation Research 1994-1995

    NASA Technical Reports Server (NTRS)

    Remer, J. H.

    1998-01-01

    The Joint University Program for Air Transportation Research (JUP) is a coordinated set of three grants co-sponsored by the Federal Aviation Administration (FAA) and the National Aeronautics and Space Administration (NASA). Under JUP, three institutions: the Massachusetts Institute of Technology, Princeton, and Ohio Universities receive research grants and collaborate with FAA and NASA in defining and performing civil aeronautics research in a multitude of areas. Some of these disciplines are artificial intelligence, control theory, atmospheric hazards, navigation, avionics, human factors, flight dynamics, air traffic management, and electronic communications.

Top