Mutlu, Ilven; Oktay, Enver
2013-04-01
Highly porous 17-4 PH stainless steel foam for biomedical applications was produced by space holder technique. Metal release and weight loss from 17-4 PH stainless steel foams was investigated in simulated body fluid and artificial saliva environments by static immersion tests. Inductively coupled plasma-mass spectrometer was employed to measure the concentrations of various metal ions released from the 17-4 PH stainless steel foams into simulated body fluids and artificial saliva. Effect of immersion time and pH value on metal release and weight loss in simulated body fluid and artificial saliva were determined. Pore morphology, pore size and mechanical properties of the 17-4 PH stainless steel foams were close to human cancellous bone. Copyright © 2012 Elsevier B.V. All rights reserved.
Akay, Canan; Tanış, Merve Ç; Sevim, Handan
2017-10-13
The aim of this study was to evaluate the cytotoxic effects of 9 different soft denture liners on the viability of L-929 mouse fibroblast cells at different incubation periods by storing them in artificial saliva (AS) with different pH levels. 96 disk samples from each lining material were prepared and divided into 4 groups: GI: No treatment; GII: Stored in artificial saliva with pH 3 for 21 days; Group III: Stored in artificial saliva with pH 7 for 21 days; and Group IV: Stored in artificial saliva with pH 14 for 21 days. The cytotoxicity of the extracts to cultured mouse fibroblasts (L-929) was measured by MTT (tetrazolium salt 3-[4,5-dimethylthiazol-2-yl]-2,5-dipHnyltetrazolium bromide) assay. Data were analyzed using 1-way analysis of variation (ANOVA). It was found that for the pH 3 values of New Truliner, Trusoft, Mollosil Plus, Dentusil, TDV, and HydroCast®; for the pH 7 values of Ufi Gel P and Elite plus; and for the pH 14 values of HydroCast®, there was a noncytotoxic effect during both the 24-hour and 48-hour incubation periods. In the control group 48-hour incubation period, HydroCast®, TDV, Mollosil, 24-hour incubation period Elite plus, for pH 3 values; Elite Plus 24-hour incubation period, for pH 7 values Trusoft 48-hour incubation period there was a moderately cytotoxic effect. This in vitro study revealed that storage in artificial saliva with different pH levels can affect the cytotoxicity of soft lining materials.
Electrochemical behavior and pH stability of artificial salivas for corrosion tests.
Queiroz, Gláucia Maria Oliveira de; Silva, Leandro Freitas; Ferreira, José Tarcísio Lima; Gomes, José Antônio da Cunha P; Sathler, Lúcio
2007-01-01
It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil) and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil). It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.
In vitro assessment of artificial saliva formulations on initial enamel erosion remineralization.
Ionta, Franciny Querobim; Mendonça, Fernanda Lyrio; de Oliveira, Gabriela Cristina; de Alencar, Catarina Ribeiro Barros; Honório, Heitor Marques; Magalhães, Ana Carolina; Rios, Daniela
2014-02-01
Various formulations of artificial saliva are present in the literature and little guidance is available on the standardization of type of saliva for use in in vitro protocols for erosive studies. The aim of this study was to evaluate the remineralizing capacity of different formulations of artificial saliva on initial enamel erosive lesion. Bovine enamel blocks were subjected to short-term acidic exposure by immersion in citric acid 0.05 M (pH 2.5) for 15s, resulting in surface softening without tissue loss. Then 90 selected eroded enamel blocks were randomly and equally divided into 6 groups according to saliva formulation (n=15): Saliva 1 (contain mucin); Saliva 2 (Saliva 1 without mucin); Saliva 3; Saliva 4; Saliva 5 (contain sodium carboxymethyl cellulose) and control (C) (deionized water). After demineralization enamel blocks were subjected to remineralization by immersion in the saliva's formulations for 2h. Enamel remineralization was measured by superficial hardness test (% superficial hardness change). The data were tested using ANOVA and Tukey's test (p<0.05). All the tested formulations of artificial saliva resulted in significantly higher enamel remineralization compared to control (p<0.001). Saliva 3 showed higher percentage of enamel remineralization than Saliva 5 (p<0.05). Besides the variety of artificial saliva for erosion in vitro protocols, all the formulations tested were able to partially remineralize initial erosive lesions. Copyright © 2013. Published by Elsevier Ltd.
Barão, Valentim A R; Mathew, Mathew T; Assunção, Wirley Gonçalves; Yuan, Judy Chia-Chun; Wimmer, Markus A; Sukotjo, Cortino
2012-09-01
To investigate the role of different levels of pH of artificial saliva under simulated oral environment on the corrosion behavior of commercially pure titanium (cp-Ti) and Ti-6Al-4V alloy. Special attention is given to understand the changes in corrosion kinetics and surface characterization of Ti by using electrochemical impedance spectroscopy (EIS). Fifty-four Ti disks (15-mm diameter, 2-mm thickness) were divided into six groups (n = 9) as a function of saliva pH (3, 6.5, and 9) and Ti type. Samples were mechanically polished using standard metallographic procedures. Standard electrochemical tests, such as open circuit potential, EIS, and potentiodynamic tests were conducted in a controlled environment. Data were evaluated by two-way ANOVA, Tukey multiple comparison test, and independent t-test (α = 0.05). Ti surfaces were examined using white-light-interferometry microscopy and scanning electron microscopy (SEM). Saliva pH level significantly affected the corrosion behavior of both Ti types. At low pH, acceleration of ions exchange between Ti and saliva, and reduction of resistance of Ti surface against corrosion were observed (P < 0.05). Corrosion rate was also significantly increased in acidic medium (P < 0.05). Similar corrosion behavior was observed for both Ti types. The white-light-interferometry images of Ti surfaces show higher surface changes at low pH level. SEM images do not show detectable changes. No pitting corrosion was observed for any group. The pH level of artificial saliva influences the corrosion behavior of cp-Ti and Ti-6Al-4V alloy in that lower pH accelerates the corrosion rate and kinetics. The corrosion products may mitigate the survival rate of dental implants. © 2011 John Wiley & Sons A/S.
NASA Astrophysics Data System (ADS)
Ismayanti, D.; Triaminingsih, S.; Eriwati, Y. K.
2017-08-01
The aim of this study was to evaluate the effect of artificial saliva with different acidities on the diametral tensile strength of Resin Modified Glass Ionomer Cement (RMGIC) coated with varnish and nanofilled coating agent. The specimens coated with coating agents were immersed in artificial saliva with pH of 4.5, 5.5, and 7 for 24 hours in an incubatorat 37°C. The diametral tensile strength of the specimens was tested with Universal Testing Machine. There were no significant differences on the diametral tensile strength of all specimens that were put into groups based on the acidity of the saliva and the type of coating agent (p>0.05). Both varnish and nanofilled coating agent stayed on the RMGIC in the acidic condition that simulated the true condition of oral cavity in people with high caries risk for the 24 hours of maturation.
In vitro enamel erosion associated with commercially available original and sour candies
Wagoner, Stephanie N.; Marshall, Teresa A.; Qian, Fang; Wefel, James S.
2009-01-01
Background Exposure to acidic foods and beverages is thought to increase risk of dental erosion. We hypothesized that the erosion potential of sour candies was greater than the erosion potentials of original candies. Methods The pH and titratable acidity of candies dissolved in artificial saliva or water were measured. Lesion depths of enamel surfaces exposed to candy slurries for 25 hours were measured. Statistics included two sample t-tests and Wilcoxon rank-sum tests to identify differences between original and sour candies and correlations to identify relationships between lesion depths, pH and titratable acidity. Results Lesion depths were generally higher following exposure to sour candies compared to original candies, and for candies dissolved in water compared to artificial saliva. Lesion depths were negatively associated with initial slurry pH and positively associated with titratable acidity. Conclusions Both original and sour candies are potentially erosive, with sour candies being of greater concern. Although saliva might protect against the erosive effects of original candies, saliva is much less likely to protect against the erosive effects of sour candies. Clinical Implications Individuals at risk for candy-associated erosion, particularly those with high intakes, pocketing behaviors or decreased salivary flow, should be provided preventive guidance regarding candy habits. PMID:19571054
Puskar, Tatjana; Jevremovic, Danimir; Williams, Robert J.; Eggbeer, Dominic; Vukelic, Djordje; Budak, Igor
2014-01-01
Dental alloys for direct metal laser sintering (DMLS) are available on the market today, but there is little scientific evidence reported on their characteristics. One of them is the release of ions, as an indicator of the corrosion characteristics of a dental alloy. Within this research, the difference in the elution of metals from DMLS and cast (CM) samples of Co-Cr-Mo dental alloy in saliva-like medium of three different pH was examined by inductively-coupled plasma mass spectrometry (ICP-MS). The obtained results show that the metal elution in artificial saliva from the DMLS alloy was lower than the elution from the CM alloy. The release of all investigated metal ions was influenced by the acidity, both from the DMLS and CM alloy, throughout the investigated period of 30 days. The change in acidity from a pH of 6.8 to a pH of 2.3 for the cast alloy led to a higher increase of the elution of Co, Cr and Mo from CM than from the DMLS alloy. The greatest release out of Co, Cr and Mo was for Co for both tested alloys. Further, the greatest release of all ions was measured at pH 2.3. In saliva of pH 2.3 and pH 4.5, the longer the investigated period, the higher the difference between the total metal ion release from the CM and DMLS alloys. Both alloys showed a safe level of elution according to the ISO definition in all investigated acidic environments. PMID:28788197
Puskar, Tatjana; Jevremovic, Danimir; Williams, Robert J; Eggbeer, Dominic; Vukelic, Djordje; Budak, Igor
2014-09-11
Dental alloys for direct metal laser sintering (DMLS) are available on the market today, but there is little scientific evidence reported on their characteristics. One of them is the release of ions, as an indicator of the corrosion characteristics of a dental alloy. Within this research, the difference in the elution of metals from DMLS and cast (CM) samples of Co-Cr-Mo dental alloy in saliva-like medium of three different pH was examined by inductively-coupled plasma mass spectrometry (ICP-MS). The obtained results show that the metal elution in artificial saliva from the DMLS alloy was lower than the elution from the CM alloy. The release of all investigated metal ions was influenced by the acidity, both from the DMLS and CM alloy, throughout the investigated period of 30 days. The change in acidity from a pH of 6.8 to a pH of 2.3 for the cast alloy led to a higher increase of the elution of Co, Cr and Mo from CM than from the DMLS alloy. The greatest release out of Co, Cr and Mo was for Co for both tested alloys. Further, the greatest release of all ions was measured at pH 2.3. In saliva of pH 2.3 and pH 4.5, the longer the investigated period, the higher the difference between the total metal ion release from the CM and DMLS alloys. Both alloys showed a safe level of elution according to the ISO definition in all investigated acidic environments.
Solubility of root-canal sealers in water and artificial saliva.
Schäfer, E; Zandbiglari, T
2003-10-01
To compare the weight loss of eight different root-canal sealers in water and in artificial saliva with different pH values. For standardized samples (n = 12 per group), ring moulds were filled with epoxy resin (AH 26, AH Plus)-, silicone (RSA RoekoSeal)-, calcium hydroxide (Apexit, Sealapex)-, zinc oxide-eugenol (Aptal-Harz)-, glass-ionomer (Ketac Endo)- and polyketone (Diaket)-based sealers. These samples were immersed in double-distilled water or artificial saliva with different pH values (7.0, 5.7 and 4.5) for 30 s, 1 min, 2 min, 5 min, 10 min, 20 min, 1 h, 2 h, 10 h, 24 h, 48 h, 72 h, 14 days and 28 days. Mean loss of weight was determined and analysed statistically using a one-way anova and Student-Newman-Keuls test for all pairwise comparisons. Most sealers were of low solubility, although Sealapex, Aptal-Harz and Ketac Endo showed a marked weight loss in all liquids. Even after 28 days of storage in water, AH 26, AH Plus, RSA RoekoSeal, and Diaket showed less than 3% weight loss. At exposure times greater than 14 days, Sealapex showed the significantly greatest weight loss of all sealers tested (P < 0.05). Aptal-Harz and Ketac Endo were significantly more soluble in saliva (pH 4.5) than in water (P < 0.05). Under the conditions of the present study, AH Plus showed the least weight loss of all sealers tested, independent of the solubility medium used. Sealapex, Aptal-Harz and Ketac Endo had a marked weight loss in all liquids.
Preventive effect of fluoridated orthodontic resins subjected to high cariogenic challenges.
Passalini, Paula; Fidalgo, Tatiana Kelly da Silva; Caldeira, Erika Machado; Gleiser, Rogerio; Nojima, Matilde da Cunha Gonçalves; Maia, Lucianne Cople
2010-01-01
The aim of the present study was to evaluate the in vitro caries preventive effect of fluoridated orthodontic resins under pH cycling with two types of acid demineralizing saliva. Brackets were bonded to 60 bovine incisors, using either Transbond Plus Color Change (n=30) or Orthodontic Fill Magic (n=30) orthodontic resins. Each group of resin was divided into 3 subgroups (n=10): immersion in remineralizing artificial saliva for 14 days, pH cycling with high cariogenic challenge in acid saliva with pH 5.5, and acid saliva with pH 4.5. After 14 days of pH cycling, the caries preventive effect on the development of white spot lesion was evaluated considering the presence of inhibition zones to white spot lesions using two scores: 0= absence and 1= presence. Kruskal Wallis and Mann-Whitney tests (a=0.05) were used. Formation of white spot lesions was observed only under pH cycling using acid saliva with pH 4.5; with Transbond Plus Color Change being significantly more effective (p<0.05) in preventing the appearance of white spot lesions effect than Orthodontic Fill Magic. The acidity of the demineralizing solution influenced the formation of white spot lesions around orthodontic brackets under highly cariogenic conditions. Transbond Plus Color Change resin presented higher caries preventive effect than Orthodontic Fill Magic.
Ajami, Shabnam; Farjood, Amin; Zare, Mahbubeh
2017-01-01
Latex elastics are still in common use due to their low cost and high flexibility to improve sagittal discrepancies or interdigitation of teeth. Mechanical properties of elastics are influenced by several environmental factors such as pH changes. This study evaluated similar latex elastics to define the influence of synergic effect of intermittent low pH and various baselines pH of saliva. Four groups of latex elastics (3-M Unitek, 3/16 inch) were tested ( n = 15 in each group). Two groups of elastics were immersed in two tanks of artificial saliva with different pH levels of 7 and 5, and two groups were immersed in two tanks of artificial saliva with intermittent drop of pH to 4. The force was measured when the elastics were stretched to 25 mm. These measurements were taken in 0, 4, 8, 12, 24, 36, and 48 h for each group. Repeated measures analysis of variance (RMANOVA) and post-hoc Tukey's test were used to assess the findings. The level of significance was 0.05%. The interaction between pH and time analyzed with RMANOVA showed no significant differences ( P > 0.05) except in 36 h ( P = 0.014). The Tukey's analysis showed that each comparison between any two groups did not indicate significant differences ( P > 0.05) except between Groups 1 and 3 and between Groups 2 and 3 ( P < 0.05). No significant correlation was seen between fluctuation of pH and force degradation in latex elastic band except in 36 h.
Wu, H; Zhang, Z X; Zhao, H P; Wu, D C; Wu, B L; Cong, R
2004-12-01
Sodium fluoride-loaded gelatin microspheres (NaF-GMS) were prepared using double-phase emulsified condensation polymerization. The average diameter of microspheres was (11.33+/-5.56) microm. The drug content and encapsulation efficiency were 8.80% and 76.73%, respectively. The fluoride releasing profiles of NaF-GMS in physiological saline and artificial saliva (pH 4.5, pH 6.8) showed that NaF-GMS had a sustained-release property and fluoride release rate was increased in pH 4.5 artificial saliva. Experiments conducted in rabbits' oral cavity using NaF-GMS and NaF solution as control revealed NaF-GMS could maintain oral fluoride retention longer than NaF solution. Cariostatic abilities of NaF-GMS including demineralization prohibition in vitro, fluoride deposition in artificial dental plaque and the ability of targeting to cariogenic bacteria were investigated in artificial dental plaque. The results indicated NaF-GMS with lower fluoride concentrations could achieve equivalent cariostatic effect to the concentrated NaF solution, at the same time, could prolong fluoride retention in dental plaque. Microscopic observation showed that NaF-GMS carrying fusion protein of glucan-binding domain could adhere more bacteria than NaF-GMS and this might indicate the possibility of targeting to cariogenic bacteria when NaF-GMS were properly modified.
Ajami, Shabnam; Farjood, Amin; Zare, Mahbubeh
2017-01-01
Background: Latex elastics are still in common use due to their low cost and high flexibility to improve sagittal discrepancies or interdigitation of teeth. Mechanical properties of elastics are influenced by several environmental factors such as pH changes. This study evaluated similar latex elastics to define the influence of synergic effect of intermittent low pH and various baselines pH of saliva. Materials and Methods: Four groups of latex elastics (3-M Unitek, 3/16 inch) were tested (n = 15 in each group). Two groups of elastics were immersed in two tanks of artificial saliva with different pH levels of 7 and 5, and two groups were immersed in two tanks of artificial saliva with intermittent drop of pH to 4. The force was measured when the elastics were stretched to 25 mm. These measurements were taken in 0, 4, 8, 12, 24, 36, and 48 h for each group. Repeated measures analysis of variance (RMANOVA) and post-hoc Tukey's test were used to assess the findings. The level of significance was 0.05%. Results: The interaction between pH and time analyzed with RMANOVA showed no significant differences (P > 0.05) except in 36 h (P = 0.014). The Tukey's analysis showed that each comparison between any two groups did not indicate significant differences (P > 0.05) except between Groups 1 and 3 and between Groups 2 and 3 (P < 0.05). Conclusion: No significant correlation was seen between fluctuation of pH and force degradation in latex elastic band except in 36 h. PMID:28348621
Mellado-Valero, Ana; Igual Muñoz, Anna; Guiñón Pina, Virginia
2018-01-01
The aim of the present study is to analyze the electrochemical behavior of five different dental alloys: two cobalt-chromium alloys (CoCr and CoCr-c), one nickel-chromium-titanium alloy (NiCrTi), one gold-palladium alloy (Au), and one titanium alloy (Ti6Al4V), and the galvanic effect when they are coupled to titanium implants (TiG2). It was carried out by electrochemical techniques (open circuit measurements, potentiodynamic curves and Zero-Resistance Ammetry) in artificial saliva (AS), with and without fluorides in different acidic conditions. The studied alloys are spontaneously passivated, but NiCrTi alloy has a very narrow passive domain and losses its passivity in presence of fluorides, so is not considered as a good option for implant superstructures. Variations of pH from 6.5 to 3 in artificial saliva do not change the electrochemical behavior of Ti, Ti6Al4V, and CoCr alloys, and couples, but when the pH of the artificial saliva is below 3.5 and the fluoride content is 1000 ppm Ti and Ti6Al4V starts actively dissolving, and CoCr-c superstructures coupled to Ti show acceleration of corrosion due to galvanic effects. Thus, NiCrTi is not recommended for implant superstructures because of risk of Ni ion release to the body, and fluorides should be avoided in acidic media because Ti, Ti6Al4V, and CoCr-c superstructures show galvanic corrosion. The best combinations are Ti/Ti6Al4V and Ti/CoCr as alternative of noble gold alloys. PMID:29361767
Mellado-Valero, Ana; Muñoz, Anna Igual; Pina, Virginia Guiñón; Sola-Ruiz, Ma Fernanda
2018-01-22
The aim of the present study is to analyze the electrochemical behavior of five different dental alloys: two cobalt-chromium alloys (CoCr and CoCr-c), one nickel-chromium-titanium alloy (NiCrTi), one gold-palladium alloy (Au), and one titanium alloy (Ti6Al4V), and the galvanic effect when they are coupled to titanium implants (TiG2). It was carried out by electrochemical techniques (open circuit measurements, potentiodynamic curves and Zero-Resistance Ammetry) in artificial saliva (AS), with and without fluorides in different acidic conditions. The studied alloys are spontaneously passivated, but NiCrTi alloy has a very narrow passive domain and losses its passivity in presence of fluorides, so is not considered as a good option for implant superstructures. Variations of pH from 6.5 to 3 in artificial saliva do not change the electrochemical behavior of Ti, Ti6Al4V, and CoCr alloys, and couples, but when the pH of the artificial saliva is below 3.5 and the fluoride content is 1000 ppm Ti and Ti6Al4V starts actively dissolving, and CoCr-c superstructures coupled to Ti show acceleration of corrosion due to galvanic effects. Thus, NiCrTi is not recommended for implant superstructures because of risk of Ni ion release to the body, and fluorides should be avoided in acidic media because Ti, Ti6Al4V, and CoCr-c superstructures show galvanic corrosion. The best combinations are Ti/Ti6Al4V and Ti/CoCr as alternative of noble gold alloys.
Remineralization of artificial enamel lesions by theobromine.
Amaechi, B T; Porteous, N; Ramalingam, K; Mensinkai, P K; Ccahuana Vasquez, R A; Sadeghpour, A; Nakamoto, T
2013-01-01
This study investigated the remineralization potential of theobromine in comparison to a standard NaF dentifrice. Three tooth blocks were produced from each of 30 teeth. Caries-like lesion was created on each block using acidified gel. A smaller block was cut from each block for baseline scanning electron microscopy imaging and electron-dispersive spectroscopy (EDS) analysis for surface Ca level. A tooth slice was cut from each lesion-bearing block for transverse microradiography (TMR) quantification of baseline mineral loss (Δz) and lesion depth (LD). Then baseline surface microhardness (SMH) of each lesion was measured. The three blocks from each tooth were assigned to three remineralizing agents: (1) artificial saliva; (2) artificial saliva with theobromine (0.0011 mol/l), and (3) NaF toothpaste slurry (0.0789 mol/l F). Remineralization was conducted using a pH cycling model with storage in artificial saliva. After a 28-day cycle, samples were analyzed using EDS, TMR, and SMH. Intragroup comparison of pre- and posttest data was performed using t tests (p < 0.05). Intergroup comparisons were performed by post hoc multistep comparisons (Tukey). SMH indicated significant (p < 0.01) remineralization only with theobromine (38 ± 32%) and toothpaste (29 ± 16%). With TMR (Δz/lD), theobromine and toothpaste exhibited significantly (p < 0.01) higher mineral gain relative to artificial saliva. With SMH and TMR, remineralization produced by theobromine and toothpaste was not significantly different. With EDS, calcium deposition was significant in all groups, but not significantly different among the groups (theobromine 13 ± 8%, toothpaste 10 ± 5%, and artificial saliva 6 ± 8%). The present study demonstrated that theobromine in an apatite-forming medium can enhance the remineralization potential of the medium. Copyright © 2013 S. Karger AG, Basel.
Hobbelink, Marieke G; He, Yan; Xu, Jia; Xie, Huixu; Stoll, Richard; Ye, Qingsong
2015-01-01
The aim of this study was to investigate the corrosive behaviour of stainless steel archwires in a more clinically relevant way by bending and exposing to various pH. One hundred and twenty pieces of rectangular stainless steel wires (0.43 × 0.64 mm) were randomly assigned into four groups. In each group, there were 15 pieces of bent wires and 15 straight ones. Prior to measurements of the wires, as individual experimental groups (group 1, 2, and 3), the wires were exposed to artificial saliva for 4 weeks at pH 5.6, 6.6, and 7.6, respectively. A control group of wires (group 4) remained in air for the same period of time before sent for measurements. Surface roughness (Ra-value) was measured by a profilometer. Young's modulus and maximum force were determined by a four-point flexural test apparatus. Scanning electron microscopy was used to observe the surface morphology of straight wire. Differences between groups were examined using a two-way analysis of variance (ANOVA). Mean surface roughness values, flexural Young's moduli, and maximum force values of bent wires are significantly different from those of the straight wires, which was the main effect of wire bending, ignoring the influence of pH. A significant effect was found between Ra-values regarding the main effect of pH, ignoring the influence of shape. There was a significant interaction effect of bending and pH on flexural Young's moduli of stainless steel archwires, while pH did not show much impact on the maximum force values of those stainless steel wires. Bigger surface irregularities were seen on SEM images of straight wires immersed in artificial saliva at pH 5.6 compared to artificial saliva at other pH values. Surface depth (Rz) was more sensitive than Ra in revealing surface roughness, both measured from 3D reconstructed SEM images. Ra showed a comparable result of surface roughness to Ra-value measured by the profilometer. Bending has a significant influence on surface roughness and mechanical properties of rectangular SS archwires. pH plays a synergistic effect on the change of mechanical properties of stainless steel (SS) wires along with wire bending.
Batra, Renu; Kataria, Pratik; Kapoor, Sonali
2016-10-01
Scientifically and clinically there has been lot of development in the field of aesthetic dentistry. However, there is limited or restricted information regarding the color stability of flowable composite materials. The aim of this study was to evaluate the spectrophotometric color stability of three different flowable composite materials with respect to three different pH of saliva. The study included 90 different samples. Thirty samples in each composite group; (Group A: G-aenial universal flo; Group B: Z 350 XT flowable; Group C: Esthet x flow). All samples from each group were immersed in distilled water for 24 hours. Total color difference (ΔE) was recorded for each sample. After this 10 samples from each group were respectively immersed in 6.5, 7 and 7.5 pH of artificial saliva. All samples were kept in dark room for seven days and then ΔE for each sample was recorded and was compared to previous recorded ΔE for the same sample. Maximum color change was seen irrespective of material in 6.5 pH of saliva. G-aenial universal flo showed least change irrespective of pH of saliva. Thus, the present study reveals that acidic pH level affects the coloration of composite resins by affecting the surface integrity and as reported in previous studies, various coloring agents in beverages and other dietary components assists the process due to absorption of these coloring substances into the resin matrix.
Matos, Irma C; Bastos, Ivan N; Diniz, Marília G; de Miranda, Mauro S
2015-08-01
Fixed prosthesis and partial dental prosthesis frameworks are usually made from welded Ni-Cr-based alloys. These structures can corrode in saliva and have to be investigated to establish their safety. The purpose of this study was to evaluate the corrosion behavior of joints joined by tungsten inert gas (TIG) welding and conventional brazing in specimens made of commercial Ni-Cr alloy in Fusayama artificial saliva at 37°C (pH 2.5 and 5.5). Eighteen Ni-Cr base metal specimens were cast and welded by brazing or tungsten inert gas methods. The specimens were divided into 3 groups (base metal, 2 welded specimens), and the composition and microstructure were qualitatively evaluated. The results of potential corrosion and corrosion current density were analyzed with a 1-way analysis of variance and the Tukey test for pairwise comparisons (α=.05). Base metal and tungsten inert gas welded material showed equivalent results in electrochemical corrosion tests, while the air-torched specimens exhibited low corrosion resistance. The performance was worst at pH 2.5. These results suggest that tungsten inert gas is a suitable welding process for use in dentistry, because the final microstructure does not reduce the corrosion resistance in artificial saliva at 37°C, even in a corrosion-testing medium that facilitates galvanic corrosion processes. Moreover, the corrosion current density of brazed Ni-Cr alloy joints was significantly higher (P<.001) than the base metal and tungsten inert gas welded joints. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Effects of environment on the release of Ni, Cr, Fe, and Co from new and recast Ni-Cr alloy.
Oyar, Perihan; Can, Gülşen; Atakol, Orhan
2014-07-01
The addition of previously cast alloy to new alloy for economic reasons may increase the release of elements. The purpose of this study was to analyze the effects of the immersion period, immersion media, and addition of previously cast alloy to new alloy on the release of elements. Disk-shaped specimens were prepared from a Ni-Cr alloy (Ni: 61 wt%, Cr: 26 wt%, Mo: 11 wt%, Si: 1.5 wt%, Fe, Ce, Al, and Co <1 wt%) (Remanium CS; Dentaurum) with new alloy (group N) and 50% new/50% recast alloy (group R). After the immersion of the specimens in both NaCl (pH 4) and artificial saliva (pH 6.7) for 3, 7, 14, 30, and 60 days, the release of ions was determined by using atomic absorption spectrometry. Data were analyzed with a 3-way ANOVA (α=.001). The release of Ni was significantly affected by the immersion period, of Ni and Cr by the alloy and media (P<.01), and of Fe by the alloy (P<.01). Ion release from the recast alloy in artificial saliva was 109.71 for Ni, 6.49 for Cr, 223.22 for Fe, and 29.90 μg/L for Co. The release of Co in NaCl was below the detection limit in both groups. The release of Ni in NaCl and artificial saliva increased with the length of the immersion period in both groups. The release of Cr and Fe was higher in artificial saliva than in NaCl in group R, regardless of the immersion period. The release of Co in NaCl was below the detection limit in both groups. Copyright © 2014 The Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Saliva with reduced calcium and phosphorous concentrations: Effect on erosion dental lesions.
Denucci, Giovanna Corrêa; Mantilla, Taís Fonseca; Amaral, Flávia Lucisano Botelho; Basting, Roberta Tarkany; França, Fabiana Mantovani Gomes; Turssi, Cecilia Pedroso
2018-02-08
To investigate whether saliva formulations with reduced calcium (Ca) and inorganic phosphorous (Pi) concentration would affect dental erosion caused by hydrochloric acid (HCl). Enamel and root dentine bovine slabs were embedded, polished and measured for surface Knoop microhardness (SMH). After reference areas were created, specimens were exposed to HCl solution (0.01M; pH 2; 120s) and immersed in artificial salivas (6h) containing three different Ca/Pi concentrations (n=15), which simulate serum conditions of normo-, mild- or severe hypocalcaemia. The control group was immersed in Ca/Pi-free saliva. The study protocol was carried out 2x/day for 5 days. Surface loss of enamel and root dentine was assessed using an optical profilometer and SMH was remeasured for enamel. ANOVA (p<0.001) and Tukey's test showed that enamel loss in groups subjected to artificial salivas that simulated mild- or severe hypocalcaemia did not differ from that resembling normocalcemia. %SMH was lower when saliva was mildly- and normally-concentrated in Ca/Pi (p<0.001). Root dentine loss was higher in saliva simulating severe hypocalcaemia than in those referring to mild, hypo- and normocalcemia. Depending on the dental substrate, salivary formulations resembling serum hypocalcaemia affected surface loss due to erosion and rehardening thereof. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Influence of stress corrosion on the mechanical properties of laser-welded titanium.
de Assis Ferreira, Nancy; Senna, Plinio Mendes; do Lago, Dalva Cristina Baptista; de Senna, Lilian Ferreira; Sampaio-Filho, Helio Rodrigues
2016-03-01
Whether laser-welded (LW) titanium can resist the stress corrosion produced by the combination of fluoride ions and stress in the oral environment is unknown. The purpose of this in vitro study was to investigate the influence of stress corrosion on the mechanical properties of LW titanium. Twenty-seven titanium bars (25×2 mm) with a circular cross-section were cut in half and laser-welded, while another 27 nonwelded (NW) bars were used as the control. Thirty bars were submitted to a flexural load of 480 N at 1 Hz and immersed in artificial saliva at pH 6 (S1) or in 1000 ppm fluoride-containing saliva at pH 6.0 (S2) or 2.0 (S3) at room temperature for up to 4000 cycles. After the stress corrosion simulation, the tensile strength and Vickers microhardness were determined (n=5). Twelve LW and NW bars were submitted to the corrosion immersion test media for 51 days (n=2) to determine polarization curves (n=2) in an artificial saliva media. The corroded surface was examined with scanning electron microscopy (SEM). The combination of fluoride and low pH significantly decreased the tensile strength of LW (P<.05). Stress corrosion did not affect the hardness of LW or NW (P>.05). NW bars immersed in S3 exhibited progressive surface dissolution, while LW bars spontaneously fractured at the welded area after 25 days of immersion in the same medium. SEM images demonstrated pitting corrosion without the presence of cracks in both groups immersed in S3. Stress corrosion caused by acidic fluoride-containing saliva and flexural load cycling decreased the tensile strength and hardness of LW titanium bars. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Titanium Ions Release from an Innovative Titanium-Magnesium Composite: an in Vitro Study.
Stanec, Zlatko; Halambek, Jasna; Maldini, Krešimir; Balog, Martin; Križik, Peter; Schauperl, Zdravko; Ćatić, Amir
2016-03-01
The innovative titanium-magnesium composite (Ti-Mg) was produced by powder metallurgy (P/M) method and is characterized in terms of corrosion behavior. Two groups of experimental material, 1 mass% (Ti-1Mg) and 2 mass% (Ti-2Mg) of magnesium in titanium matrix, were tested and compared to commercially pure titanium (CP Ti). Immersion test and chemical analysis of four solutions: artificial saliva; artificial saliva pH 4; artificial saliva with fluoride and Hank balanced salt solution were performed after 42 days of immersion, using inductively coupled plasma mass spectrometry (ICP-MS) to detect the amount of released titanium ions (Ti). SEM and EDS analysis were used for surface characterization. The difference between the results from different test solutions was assessed by ANOVA and Newman-Keuls test at p<0.05. The influence of predictor variables was found by multiple regression analysis. The results of the present study revealed a low corrosion rate of titanium from the experimental Ti-Mg group. Up to 46 and 23 times lower dissolution of Ti from Ti-1Mg and Ti-2Mg, respectively was observed compared to the control group. Among the tested solutions, artificial saliva with fluorides exhibited the highest corrosion effect on all specimens tested. SEM micrographs showed preserved dual phase surface structure and EDS analysis suggested a favorable surface bioactivity. In conclusion, Ti-Mg produced by P/M as a material with better corrosion properties when compared to CP Ti is suggested.
Novel amelogenin-releasing hydrogel for remineralization of enamel artificial caries
Fan, Yuwei; Wen, Zezhang T; Liao, Sumei; Lallier, Thomas; Hagan, Joseph L; Twomley, Jefferson T; Zhang, Jian-Feng; Sun, Zhi; Xu, Xiaoming
2013-01-01
Recently, the use of recombinant full-length amelogenin protein in combination with fluoride has shown promising results in the formation of densely packed enamel-like structures. In this study, amelogenin (rP172)-releasing hydrogels containing calcium, phosphate, and fluoride were investigated for remineralization efficacy using in vitro early enamel caries models. The hydrogels were applied to artificial caries lesions on extracted human third molars, and the remineralization efficacy was tested in different models: static gel remineralization in the presence of artificial saliva, pH cyclic treatment at pH 5.4 acetic buffer and pH 7.3 gel remineralization, and treatment with multispecies oral biofilms grown in a continuous flowing constant-depth film fermenter. The surface microhardness of remineralized enamel increased significantly when amelogenin was released from hydrogel. No cytotoxicity was observed when periodontal ligament cells were cultured with the mineralized hydrogels. PMID:23338820
Matsuyoshi, Saki; Murayama, Ryosuke; Akiba, Shunsuke; Yabuki, Chiaki; Takamizawa, Toshiki; Kurokawa, Hiroyasu; Miyazaki, Masashi
2017-04-01
The purpose of this study was to examine the effects of a dentifrice containing 5% calcium sodium phosphosilicate (CSP) on the remineralization of the enamel using optical coherence tomography (OCT). Bovine incisors were sliced and shaped in a rectangular form. One group of five specimens was treated with undersaturated 0.1 M lactic acid buffer solution (pH 4.75) for 10 min and then placed in artificial saliva (pH 7.0) (De group). Other specimens were stored in solutions of toothpaste containing CSP for 10 min, followed by 10-min immersion in the lactic acid buffer solution twice a day before storage in artificial saliva (CSP group). An additional group was stored in only artificial saliva (control group). OCT imaging on the selected location of the enamel surface was performed. The peak intensity and width at 1/e 2 were recorded in each of the six areas on the sample and averaged, and the sample size of each group was six. The integrated value in units (dB × μm) was calculated in the area of peak intensity. The data for each group was subjected to one-way repeated-measures ANOVA and Tukey HSD tests (α = 0.05). The changes in integrated values of each group were different. A slight but significant increase in the integrated value was observed in the control group, whereas a slight but significant decrease in the value was observed the De group. Integrated values increased in the CSP group. Remineralization occurred upon immersion in the toothpaste containing CSP.
Titanium Ions Release from an Innovative Titanium-Magnesium Composite: an in Vitro Study
Halambek, Jasna; Maldini, Krešimir; Balog, Martin; Križik, Peter; Schauperl, Zdravko; Ćatić, Amir
2016-01-01
Background The innovative titanium-magnesium composite (Ti-Mg) was produced by powder metallurgy (P/M) method and is characterized in terms of corrosion behavior. Material and methods Two groups of experimental material, 1 mass% (Ti-1Mg) and 2 mass% (Ti-2Mg) of magnesium in titanium matrix, were tested and compared to commercially pure titanium (CP Ti). Immersion test and chemical analysis of four solutions: artificial saliva; artificial saliva pH 4; artificial saliva with fluoride and Hank balanced salt solution were performed after 42 days of immersion, using inductively coupled plasma mass spectrometry (ICP-MS) to detect the amount of released titanium ions (Ti). SEM and EDS analysis were used for surface characterization. Results The difference between the results from different test solutions was assessed by ANOVA and Newman-Keuls test at p<0.05. The influence of predictor variables was found by multiple regression analysis. The results of the present study revealed a low corrosion rate of titanium from the experimental Ti-Mg group. Up to 46 and 23 times lower dissolution of Ti from Ti-1Mg and Ti-2Mg, respectively was observed compared to the control group. Among the tested solutions, artificial saliva with fluorides exhibited the highest corrosion effect on all specimens tested. SEM micrographs showed preserved dual phase surface structure and EDS analysis suggested a favorable surface bioactivity. Conclusion In conclusion, Ti-Mg produced by P/M as a material with better corrosion properties when compared to CP Ti is suggested. PMID:27688425
Carbohydrate-electrolyte drinks exhibit risks for human enamel surface loss
Passos, Vanara Florêncio; Lima, Juliana Paiva Marques; Santiago, Sérgio Lima; Rodrigues, Lidiany Karla Azevedo
2016-01-01
Objectives The aim of this investigation was to give insights into the impact of carbohydrate-electrolyte drinks on the likely capacity of enamel surface dissolution and the influence of human saliva exposure as a biological protective factor. Materials and Methods The pH, titratable acidity (TA) to pH 7.0, and buffer capacity (β) of common beverages ingested by patients under physical activity were analyzed. Then, we randomly distributed 50 specimens of human enamel into 5 groups. Processed and natural coconut water served as controls for testing three carbohydrate-electrolyte drinks. In all specimens, we measured surface microhardness (Knoop hardness numbers) and enamel loss (profilometry, µm) for baseline and after simulated intake cycling exposure model. We also prepared areas of specimens to be exposed to human saliva overnight prior to the simulated intake cycling exposure. The cycles were performed by alternated immersions in beverages and artificial saliva. ANOVA two-way and Tukey HDS tests were used. Results The range of pH, TA, and β were 2.85 - 4.81, 8.33 - 46.66 mM/L and 3.48 - 10.25 mM/L × pH, respectively. The highest capacity of enamel surface dissolution was found for commercially available sports drinks for all variables. Single time human saliva exposure failed to significantly promote protective effect for the acidic attack of beverages. Conclusions In this study, carbohydrate-electrolyte drinks usually consumed during endurance training may have a greater capacity of dissolution of enamel surface depending on their physicochemical proprieties associated with pH and titratable acidity. PMID:27847745
Degradation of orthodontic wires under simulated cariogenic and erosive conditions.
Jaber, Laura Cavalcante Lima; Rodrigues, José Augusto; Amaral, Flávia Lucisano Botelho; França, Fabiana Mantovani Gomes; Basting, Roberta Tarkany; Turssi, Cecilia Pedroso
2014-01-01
This study examined the effect of cariogenic and erosive challenges (CCs and ECs, respectively) on the degradation of copper-nickel-titanium (CuNiTi) orthodontic wires. Sixty wire segments were divided into four treatment groups and exposed to CCs, ECs, artificial saliva, or dry storage (no-treatment control). CC and EC were simulated using a demineralizing solution (pH 4.3) and a citric acid solution (pH 2.3), respectively. Following treatment, the average surface roughness (Ra) of the wires was assessed, and friction between the wires and a passive self-ligating bracket was measured. CuNiTi wires subjected to ECs exhibited significantly higher Ra values than did those that were stored in artificial saliva. In contrast, surface roughness was not affected by CCs. Finally, friction between the treated wires and brackets was not affected by ECs or CCs. Our results indicate that CuNiTi orthodontic wires may suffer degradation within the oral cavity, as ECs increased the surface roughness of these wires. However, rougher surfaces did not increase friction between the wire and the passive self-ligating bracket.
Maletz, Reinhard; Ottl, Peter; Warkentin, Mareike
2018-01-01
Objective Over time dental composites age due to mechanical impacts such as chewing and chemical impacts such as saliva enzymes and food ingredients. For this research, the focus was placed on chemical degradation. The objective of this study was to simulate hydrolysis by using different food simulating liquids and to assess their impact on the mechanical parameter Vickers microhardness (MHV) and the physicochemical parameter contact angle (CA). Methods Specimen of three composites (d = 6 mm, h = 2 mm; n = 435) classified with respect to their filler content (wt%), namely low-filled, medium-filled and highly-filled, were stored for 0, 14, 30, 90 and 180 days in artificial saliva (pH 7), citric acid (pH 3; pH 5), lactic acid (pH 3; pH 5) and ethanol (40%vol; 60%vol) and assessed regarding to MHV and CA. Statistics: Kruskal-Wallis test, stepwise linear regression, bivariate Spearman Rank Correlation (p < 0.05). Results While stored in artificial saliva, acid and ethanol the CA decreased especially for the low- and medium-filled composites. It was shown that rising the filler content caused less surface changes in the CA. Storage in ethanol led to a significant decrease of MHV of all composites. Regression analysis showed that the effect of in vitro aging on MHV was mainly influenced by the composite material and therefore by filler content (R2 = 0.67; p < 0.05). In contrast, the CA is more influenced by incubation time and filler content (R2 = 0.2; p < 0.05) leading to a higher risk of plaque accumulation over time. Significance: In vitro aging showed significant changes on the mechanical and physicochemical properties of dental composites which may shorten their long-term functionality. In conclusion, it can be stated, that the type of composite material, especially rising filler content seems to improve the materials’ resistance against the processes of chemical degradation. PMID:29630621
Comparison of metal release from various metallic biomaterials in vitro.
Okazaki, Yoshimitsu; Gotoh, Emiko
2005-01-01
To investigate the metal release of each base and alloying elements in vitro, SUS316L stainless steel, Co-Cr-Mo casting alloy, commercially pure Ti grade 2, and Ti-6Al-4V, V-free Ti-6Al-7Nb and Ti-15Zr-4Nb-4Ta alloys were immersed in various solutions, namely, alpha-medium, PBS(-), calf serum, 0.9% NaCl, artificial saliva, 1.2 mass% L-cysteine, 1 mass% lactic acid and 0.01 mass% HCl for 7d. The difference in the quantity of Co released from the Co-Cr-Mo casting alloy was relatively small in all the solutions. The quantities of Ti released into alpha-medium, PBS(-), calf serum, 0.9% NaCl and artificial saliva were much lower than those released into 1.2% L-cysteine, 1% lactic acid and 0.01% HCl. The quantity of Fe released from SUS316L stainless steel decreased linearly with increasing pH. On the other hand, the quantity of Ti released from Ti materials increased with decreasing pH, and it markedly attenuated at pHs of approximately 4 and higher. The quantity of Ni released from stainless steel gradually decreased with increasing pH. The quantities of Al released from the Ti-6Al-4V and Ti-6Al-7Nb alloys gradually decreased with increasing pH. A small V release was observed in calf serum, PBS(-), artificial saliva, 1% lactic acid, 1.2% l-cysteine and 0.01% HCl. The quantity of Ti released from the Ti-15Zr-4Nb-4Ta alloy was smaller than those released from the Ti-6Al-4V and Ti-6Al-7Nb alloys in all the solutions. In particular, it was approximately 30% or smaller in 1% lactic acid, 1.2% L-cysteine and 0.01% HCl. The quantity of (Zr + Nb + Ta) released was also considerably lower than that of (Al + Nb) or (Al + V) released. Therefore, the Ti-15Zr-4Nb-4Ta alloy with its low metal release in vitro is considered advantageous for long-term implants. Copyright 2004 Elsevier Ltd.
Bots, Casper P; Brand, Henk S; Veerman, Enno C I; Valentijn-Benz, Marianne; Van Amerongen, Barbara M; Nieuw Amerongen, Arie V; Valentijn, Robert M; Vos, Pieter F; Bijlsma, Joost A; Bezemer, Pieter D; ter Wee, Piet M
2005-04-01
Many patients on haemodialysis (HD) therapy suffer from a dry mouth and xerostomia. This can be relieved by mechanical and gustatory stimulation or palliative care. The aim of this crossover study was to investigate the effect and preferences of a sugar-free chewing gum (Freedent White) and a xanthan gum-based artificial saliva (Xialine) in the management of xerostomia in chronic HD patients. Sixty-five HD patients participated in a 6-week crossover trial. The artificial saliva was rated significantly lower than the chewing gum for effectiveness, taste and a global assessment. No preference differences were found for gender and age, although older subjects rated the artificial saliva with a higher mark. Thirty-nine subjects (60%) preferred chewing gum, 15% (n=10) preferred the artificial saliva. Therefore, both chewing gum and artificial saliva could play an important role in the palliative care of xerostomia in HD patients.
Effect of thermocycling on nickel release from orthodontic arch wires: an in vitro study.
Sheibaninia, Ahmad
2014-12-01
The amount of daily intake of metals from orthodontic appliances over time is a matter of great concern. Nickel results in one of the most common metal-induced allergic contact dermatitis in humans; it produces more allergic reactions than all the other metals combined together. The purpose of this study was to evaluate the effects of thermocycling on the nickel release from orthodontic arch wires stored in artificial saliva with different pH values. Forty new wire pieces were selected. Each wire piece was placed in a special capillary Pyrex tube filled with artificial saliva, which was sealed and immersed in deionized water at 37 °C. The samples were divided into four groups of ten. Group I received no treatment; group II was subjected to thermocycling. The pH of storage in groups III and IV was reduced to 4.5, and group IV was subjected to thermocycling. Thermocycling was carried out between 5 and 55 °C for 500 cycles. The release of nickel ions was statistically analyzed by two-way ANOVA for the effects of two variables: pH and thermocycling. The interaction between pH and thermocycling was found to be statistically significant (F = 12.127, P = 0.001). Two-way ANOVA showed that different storage media or pH and thermocycling had a significant effect on the nickel release (F = 52.812, P < 0.001 and F = 197.035, P < 0.001, respectively). Thermocycling and pH can adversely affect the release of nickel from orthodontic wires, while thermocycling is clearly the dominant factor.
Mayworm, Camila D; Camargo, Sérgio S; Bastian, Fernando L
2008-09-01
The aim of this study is to compare the wear resistance and hardness of two dental nanohybrid composites and to evaluate the influence of artificial saliva storage on those properties. Specimens were made from two commercial nanohybrid dental composites (Esthet-X-Dentsply and Filtek Supreme-3M). Abrasion tests were carried out in a ball-cratering machine (three body abrasion) and microscopic analysis of the wear surfaces was made using optical and scanning electron microscopy; hardness was quantified by Vickers hardness test. Those tests were repeated on specimens stored in artificial saliva. Results show that the wear rate of the studied materials is within 10(-7)mm(3)/Nmm range, one of the composites presenting wear rate twice as large as the other. After storage in artificial saliva, the wear resistance increases for both materials. Microhardness of the composites is around 52 and 64HV, Esthet-X presents higher hardness values than Filtek Supreme. After storage in artificial saliva, the microhardness of both materials decreases. Data were analyzed using ANOVA test, p < or = 0.05. Artificial saliva storage increases the materials' wear resistance, suggesting that in both materials bulk post-cure takes place and saliva absorption occurs only on the surface of the composites. This effect was confirmed by comparing the Vickers hardness before and after artificial saliva treatment and FTIR analyses. Surface microhardness of the composites decreases after storage in artificial saliva whereas bulk microhardness of the materials increases.
Panich, Muratha; Poolthong, Suchit
2009-04-01
The authors conducted an in vitro study to compare the hardness of normal enamel with enamel eroded by a cola soft drink and enamel remineralized by casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) or artificial saliva. The authors immersed 40 extracted sound central and lateral incisors alternately in a cola soft drink or artificial saliva for 10 cycles of five seconds each. They repeated this procedure two times at six-hour intervals. They divided the samples randomly into four groups and applied CPP-ACP to the samples, immersed them in artificial saliva, deionized water or both. They measured the hardness on the labial surface at baseline, after erosion and after remineralization and analyzed the data with one-way repeated-measures analysis of variance and two-way analysis of variance. The cola soft drink significantly decreased enamel hardness. CPP-ACP and CPP-ACP and artificial saliva significantly increased the hardness of eroded enamel. CPP-ACP and CPP-ACP and artificial saliva increased the hardness of eroded enamel significantly more than artificial saliva did. CPP-ACP increased the hardness of eroded enamel. CPP-ACP had a greater effect on enamel hardness than did artificial saliva. Consumption of a cola soft drink can cause tooth erosion. CPP-ACP may significantly remineralize eroded enamel compared with artificial saliva.
An In Vitro Study of the Effect of Fluoridated Milk on Oral Bacterial Biofilms
Pratten, J.; Bedi, R.; Wilson, M.
2000-01-01
Microcosmic dental plaques were grown in artificial saliva and supplemented with either milk or fluoridated milk. The presence of fluoride in the milk increased the pH of the biofilms and reduced the proportions of streptococci, demonstrating that in this model, fluoridation of milk produces biofilms with reduced cariogenic potential. PMID:10742268
Understanding of xerostomia and strategies for the development of artificial saliva.
Kho, Hong-Seop
2014-01-01
Xerostomia is becoming a major issue in dental and medical clinics with an increase of aged population. Medication is the most common etiology of xerostomia, while the most severe xerostomia generally occurs in patients with a history of head and neck radiotherapy. Xerostomic patients usually suffer from diminished quality of life due to various symptoms and complications. Decreased salivary output is a definite objective sign, but oral mucosal wetness is a more reliable factor for the evaluation of xerostomia. At present there are no effective therapeutic methods for the treatment of xerostomia. Sialogogues may have problematic side effects and their therapeutic effects last only brief duration. Artificial saliva typically does not produce satisfactory results in therapeutic efficacy. Therefore, further research and development of better therapeutic modalities are necessary. The basic concept for the development of ideal and functional artificial saliva is the mimicry of natural human saliva. We need proper candidate molecules and antimicrobial supplements to simulate the rheological and biological properties of human saliva. We also need better understanding of the interactions between the ingredients of artificial saliva themselves and between the ingredients and components of human saliva both in solution and on surface phases. In addition, we need accepted measures to evaluate the efficacy of artificial saliva. In conclusion, for the development of ideal artificial saliva, research based on the understanding of pathophysiology of xerostomia and knowledge about rheological and biological functions of human saliva are necessary.
Wine pH Prevails over Buffering Capacity of Human Saliva.
Obreque-Slier, Elías; Espínola-Espínola, Valeria; López-Solís, Remigio
2016-11-02
Wine is an acidic beverage; its pH (2.9-3.8) is critically important to its organoleptic properties. During degustation, wine interacts with <1 mL of mouth saliva, the pH of which is near 7.0. This is buffered predominantly by the carbonate/bicarbonate pair (pK a = 6.1). Few data are available on whether the buffering capacity of saliva may alter the pH of wine and thus its sensorial properties. In this study both in vitro and in vivo approaches were conducted to measure pH in mixtures of representative red and white wines with human saliva. Continuous additions of microvolumes of either wine to a definite volume (3 mL) of saliva in vitro resulted in a progressive and steep decline in the pH of the wine/saliva mixture. Thus, a few microliters of either wine (<0.27 mL) was sufficient to reduce the pH of saliva by 1 pH unit. Further additions of wine to saliva lowered the pH to that of the corresponding wine. In the in vivo assay, definite volumes (1.5-18 mL) of either wine were mixed for 15 s with the mouth saliva of individual healthy subjects before pH determination in the expectorated wine/saliva mixtures. Compared to saliva, pronounced decreases in pH were observed, thus approaching the pH of wine even with the smallest volume of wine in the assay. Altogether, these results demonstrate that the buffering capacity of wine prevails over that of saliva and that during degustation the pH of the wine/saliva mixture in the mouth is, at least temporarily, that of the corresponding wine.
Fluoride release from fluoride varnishes under acidic conditions.
Lippert, F
2014-01-01
The aim was to investigate the in vitro fluoride release from fluoride varnishes under acidic conditions. Poly(methyl methacrylate) blocks (Perspex, n=3 per group) were painted with 80 ± 5 mg fluoride varnish (n=10) and placed into artificial saliva for 30 min. Then, blocks were placed into either 1% citric acid (pH 2.27) or 0.3% citric acid (pH 3.75) solutions (n=3 per solution and varnish) for 30 min with the solutions being replaced every 5 min. Saliva and acid solutions were analyzed for fluoride content. Data were analyzed using three-way ANOVA (varnish, solution, time). The three-way interaction was significant (p>0.0001). Fluoride release and release patterns varied considerably between varnishes. Fluoride release in saliva varied by a factor of more than 10 between varnishes. Some varnishes (CavityShield, Nupro, ProFluorid, Vanish) showed higher fluoride release in saliva than during the first 5 min of acid exposure, whereas other varnishes (Acclean, Enamel-Pro, MI Varnish, Vella) showed the opposite behavior. There was little difference between acidic solutions. Fluoride release from fluoride varnishes varies considerably and also depends on the dissolution medium. Bearing in mind the limitations of laboratory research, the consumption of acidic drinks after fluoride varnish application should be avoided to optimize the benefit/risk ratio.
Leakage of fluid in different types of tracheal tubes.
Winklmaier, U; Wüst, K; Schiller, S; Wallner, F
2006-10-01
The aim of this study was to evaluate leakage of liquids, i.e., water and saliva, past low-pressure cuffs of tracheostomy tubes. Three different types of tracheostomy tubes, TRACOE vario (TRACOE Medical GmbH, Germany), Rüsch Ultra-Tracheoflex (Rüsch GmbH, Germany), and Portex Blue Line Ultra (Smiths Medical, UK) were tested in isolated pig tracheas. Sixty samples (10 tubes each of 7- and 8-mm inner diameter of each type) were used. Four different experiments were devised: type 1 (water and artificial ventilation), type 2 (water and no artificial ventilation), type 3 (saliva and artificial ventilation), and type 4 (saliva and no artificial ventilation). Six milliliters of water or artificial saliva were infused over the cuff and the volume of fluid that leaked past the cuff was measured after 5, 10, and 15 min. Intracuff pressure was also measured three times. The saliva experiments resulted in less leakage than the water experiments. Leakage after treatment with water or artificial saliva is higher without artificial ventilation than with ventilation. The amount of leakage among the tubes with respect to manufacturer showed statistically significant results. However, there were no differences among tracheostomy tubes with respect to internal diameter.
Garcia, Lucas da Fonseca Roberti; Roselino, Lourenço de Moraes Rego; Mundim, Fabrício Mariano; Pires-de-Souza, Fernanda de Carvalho Panzeri; Consani, Simonides
2010-08-01
The aim of this study was to evaluate the influence of artificial accelerated aging on dimensional stability of two types of acrylic resins (thermally and chemically activated) submitted to different protocols of storage. One hundred specimens were made using a Teflon matrix (1.5 cm x 0.5 mm) with four imprint marks, following the lost-wax casting method. The specimens were divided into ten groups, according to the type of acrylic resin, aging procedure, and storage protocol (30 days). GI: acrylic resins thermally activated, aging, storage in artificial saliva for 16 hours, distilled water for 8 hours; GII: thermal, aging, artificial saliva for 16 hours, dry for 8 hours; GIII: thermal, no aging, artificial saliva for 16 hours, distilled water for 8 hours, GIV: thermal, no aging, artificial saliva for 16 hours, dry for 8 hours; GV: acrylic resins chemically activated, aging, artificial saliva for 16 hours, distilled water for 8 hours; GVI: chemical, aging, artificial saliva for 16 hours, dry for 8 hours; GVII: chemical, no aging, artificial saliva for 16 hours, distilled water for 8 hours; GVIII: chemical, no aging, artificial saliva for 16 hours, dry for 8 hours GIX: thermal, dry for 24 hours; and GX: chemical, dry for 24 hours. All specimens were photographed before and after treatment, and the images were evaluated by software (UTHSCSA - Image Tool) that made distance measurements between the marks in the specimens (mm), calculating the dimensional stability. Data were submitted to statistical analysis (two-way ANOVA, Tukey test, p= 0.05). Statistical analysis showed that the specimens submitted to storage in water presented the largest distance between both axes (major and minor), statistically different (p < 0.05) from control groups. All acrylic resins presented dimensional changes, and the artificial accelerated aging and storage period influenced these alterations.
Influence of remineralizing gels on bleached enamel microhardness in different time intervals.
Borges, Alessandra Bühler; Yui, Karen Cristina Kazue; D'Avila, Thaís Corrêa; Takahashi, Camila Lurie; Torres, Carlos Rocha Gomes; Borges, Alexandre Luis Souto
2010-01-01
This study evaluated the influence of bleaching gel pH, the effect of applying remineralizing gels after bleaching and the effect of artificial saliva on enamel microhardness. Seventy bovine incisors were divided into three groups: Group 1 (n=10) received no bleaching procedure (control); Group 2 was bleached with a 35% hydrogen peroxide neutral gel (n=30) and Group 3 was bleached with a 35% hydrogen peroxide acid gel (n=30). Each experimental group was subdivided into three groups (n=10) according to the post-bleaching treatment: storage in artificial saliva, application of a fluoride gel and application of a combination of calcium and fluoride gel. The specimens were stored in artificial saliva for 7, 15 and 30 days and enamel microhardness was evaluated. The Vickers microhardness data were analyzed by three-way RM ANOVA, which revealed a significant difference only for treatment factor. The Tukey's test showed that the groups bleached followed by no additional treatment exhibited microhardness means significantly lower than the bleached groups treated with remineralizing gels. The Dunnet's test showed a significant difference only for the group bleached with acid gel without remineralizing treatment compared to the control group measured immediately after bleaching. It was concluded that acid bleaching gel significantly reduced enamel microhardness and that use of remineralizing gels after bleaching can significantly enhance the microhardness of bleached enamel.
Tribocorrosion mechanisms of Ti6Al4V biomedical alloys in artificial saliva with different pHs
NASA Astrophysics Data System (ADS)
Licausi, M. P.; Igual Muñoz, A.; Amigó Borrás, V.
2013-10-01
Titanium and its alloys has been widely used for the design of dental implants because of its biocompatibility, mechanical properties and corrosion resistance. The powder-metallurgy process is a promising alternative to the casting fabrication process of titanium alloys for bone implants design as the porous structure mimics the natural bone structures, allowing the bone to grow into the pores which results in a better fixation of the artificial implant. However, under in vivo conditions the implants are subjected to tribocorrosion phenomenon, which consists in the degradation mechanisms due to the combined effect of wear and corrosion. The aim of this study is to evaluate the tribocorrosion behaviour of cast and sintered Ti6Al4V biomedical alloy for dental applications using the cast material as reference. Titanium samples were tested in artificial human saliva solution with three different pHs (3, 6, 9) and in an acidic saliva with 1000 ppm fluorides (AS-3-1000F-) by different electrochemical techniques (potentiodynamic curves, potentiostatic tests and tribo-electrochemical tests). Cast and sintered titanium alloys exhibit the same tribocorrosion mechanisms in AS independently of the pH which consists in plastic deformation with passive dissolution, but the addition of fluorides to the acidified solution changes the degradation mechanism towards active dissolution of the titanium alloys.
Novel sensors for the Artificial Mouth
NASA Astrophysics Data System (ADS)
Djeghlaf, Lyes; Mielle, Patrick; Maratray, Jacques; Launay, Jérôme; Temple-Boyer, Pierre; Salles, Christian
2011-09-01
Similarly to human chewing, tasty compounds are released in saliva during the food piece mastication in the `Artificial Mouth', and so, are available continuously. Glutamate is present in numerous food, as taste enhancer, has a nice and sought "umami" taste, specific receptors and different inter individual sensitivities, and is a fair marker of the release of tasty compounds. The three sensors (for pH, salt, or glutamate concentration) have the same size, so they are easily interchangeable. Up to now, only one kind of parameter may be analysed at a time by the different sensors. Nevertheless, combined electrodes may be developed in the future.
Pedrosa, Vivianne Oliveira; Flório, Flávia Martão; Turssi, Cecília Pedroso; Amaral, Flávia Lucisano; Basting, Roberta Tarkany; França, Fabiana Mantovani
2012-12-01
To evaluate the influence of pH cycling on microtensile bond strength (µTBS) and fracture pattern of MDPB- and fluoride-containing self-etching adhesive systems to dentin, and on the cross-sectional Knoop microhardness (CSMH) of enamel and dentin adjacent to restorations. The two-step self-etching adhesive Clearfil SE Bond (SE; Kuraray), the two-step MDPBand fluoride-containing adhesive Clearfil Protect Bond (PB; Kuraray), and the one-step fluoride-containing adhesive One-Up Bond F Plus (OU; Tokuyama) were used to bond resin composite to midcoronal dentin surfaces (for µTBS testing) or to Class V cavities (for CSMH testing). µTBS and CSMH tests were performed after a 15-day period of pH cycling or storage in artificial saliva. µTBS to dentin was not affected by pH cycling or storage in artificial saliva; however, µTBS values found for PB were higher than those observed for OU. No difference existed among the µTBS values shown by PB, OU, and SE. The fracture pattern was affected by both pH cycling and adhesive system. In enamel, there was no difference in CSMH values provided by the different adhesive systems and storage media, regardless of the distance and depth from restoration. In dentin, PB and SE showed the highest CSMH values, which differed from those obtained for OU. Significantly higher CSMH values were found 100 µm from the restoration margin for all adhesive systems tested. The bond strength and microhardness in the vicinity of restorations were adhesive dependent, with MDPB and fluoride exerting no effect on the performance of the adhesive systems.
Erosion protection conferred by whole human saliva, dialysed saliva, and artificial saliva
NASA Astrophysics Data System (ADS)
Baumann, T.; Kozik, J.; Lussi, A.; Carvalho, T. S.
2016-10-01
During dental erosion, tooth minerals are dissolved, leading to a softening of the surface and consequently to irreversible surface loss. Components from human saliva form a pellicle on the tooth surface, providing some protection against erosion. To assess the effect of different components and compositions of saliva on the protective potential of the pellicle against enamel erosion, we prepared four different kinds of saliva: human whole stimulated saliva (HS), artificial saliva containing only ions (AS), human saliva dialysed against artificial saliva, containing salivary proteins and ions (HS/AS), and human saliva dialysed against deionised water, containing only salivary proteins but no ions (HS/DW). Enamel specimens underwent four cycles of immersion in either HS, AS, HS/AS, HS/DW, or a humid chamber (Ctrl), followed by erosion with citric acid. During the cycling process, the surface hardness and the calcium released from the surface of the specimens were measured. The different kinds of saliva provided different levels of protection, HS/DW exhibiting significantly better protection than all the other groups (p < 0.0001). Different components of saliva, therefore, have different effects on the protective properties of the pellicle and the right proportions of these components in saliva are critical for the ability to form a protective pellicle.
Susceptibility of bovine dental enamel with initial erosion lesion to new erosive challenges
Tereza, Guida Paola Genovez; Boteon, Ana Paula; Ferrairo, Brunna Mota; Gonçalves, Priscilla Santana Pinto; da Silva, Thiago Cruvinel; Honório, Heitor Marques; Rios, Daniela
2017-01-01
This in vitro study evaluated the impact of initial erosion on the susceptibility of enamel to further erosive challenge. Thirty bovine enamel blocks were selected by surface hardness and randomized into two groups (n = 15): GC- group composed by enamel blocks without erosion lesion and GT- group composed by enamel blocks with initial erosion lesion. The baseline profile of each block was determined using the profilometer. The initial erosion was produced by immersing the blocks into HCl 0.01 M, pH 2.3 for 30 seconds, under stirring. The erosive cycling consisted of blocks immersion in hydrochloric acid (0.01 M, pH 2.3) for 2 minutes, followed by immersion in artificial saliva for 120 minutes. This procedure was repeated 4 times a day for 5 days, and the blocks were kept in artificial saliva overnight. After erosive cycling, final profile measurement was performed. Profilometry measured the enamel loss by the superposition of initial and final profiles. Data were analyzed by t-test (p<0.05). The result showed no statistically significant difference between groups (GS = 14.60±2.86 and GE = .14.69±2.21 μm). The presence of initial erosion on bovine dental enamel does not enhance its susceptibility to new erosive challenges. PMID:28817591
Susceptibility of bovine dental enamel with initial erosion lesion to new erosive challenges.
Oliveira, Gabriela Cristina de; Tereza, Guida Paola Genovez; Boteon, Ana Paula; Ferrairo, Brunna Mota; Gonçalves, Priscilla Santana Pinto; Silva, Thiago Cruvinel da; Honório, Heitor Marques; Rios, Daniela
2017-01-01
This in vitro study evaluated the impact of initial erosion on the susceptibility of enamel to further erosive challenge. Thirty bovine enamel blocks were selected by surface hardness and randomized into two groups (n = 15): GC- group composed by enamel blocks without erosion lesion and GT- group composed by enamel blocks with initial erosion lesion. The baseline profile of each block was determined using the profilometer. The initial erosion was produced by immersing the blocks into HCl 0.01 M, pH 2.3 for 30 seconds, under stirring. The erosive cycling consisted of blocks immersion in hydrochloric acid (0.01 M, pH 2.3) for 2 minutes, followed by immersion in artificial saliva for 120 minutes. This procedure was repeated 4 times a day for 5 days, and the blocks were kept in artificial saliva overnight. After erosive cycling, final profile measurement was performed. Profilometry measured the enamel loss by the superposition of initial and final profiles. Data were analyzed by t-test (p<0.05). The result showed no statistically significant difference between groups (GS = 14.60±2.86 and GE = .14.69±2.21 μm). The presence of initial erosion on bovine dental enamel does not enhance its susceptibility to new erosive challenges.
Corrosion Behavior of AZ91D Magnesium Alloy in Three Different Physiological Environments
NASA Astrophysics Data System (ADS)
Zhou, Juncen; Li, Qing; Zhang, Haixiao; Chen, Funan
2014-01-01
Magnesium alloys have been considered as promising biomedical materials and were studied in different physiological environments. In this work, corrosion behavior of AZ91D magnesium alloy in artificial saliva, simulated body fluid (SBF), and 3.5 wt.% NaCl solution was investigated using electrochemical techniques and a short-term immersion test. In contrast with other physiological environments, the amount of aggressive ions in artificial saliva is small. In addition, a protective film is formed on the surface of samples in artificial saliva. Experimental results suggest that corrosion resistance of AZ91D magnesium alloy in artificial saliva is better than that in c-SBF and 3.5 wt.% NaCl solution.
Production and Precipitation Hardening of Beta-Type Ti-35Nb-10Cu Alloy Foam for Implant Applications
NASA Astrophysics Data System (ADS)
Mutlu, Ilven; Yeniyol, Sinem; Oktay, Enver
2016-04-01
In this study, beta-type Ti-35Nb-10Cu alloy foams were produced by powder metallurgy method for dental implant applications. 35% Nb was added to stabilize the beta-Ti phase with low Young's modulus. Cu addition enhanced sinterability and gave precipitation hardening capacity to the alloy. Sintered specimens were precipitation hardened in order to enhance the mechanical properties. Electrochemical corrosion behavior of the specimens was examined by electrochemical impedance spectroscopy in artificial saliva. Electrochemical impedance spectroscopy results indicated that the oxide film on the surface of foam is a bi-layer structure consisting of outer porous layer and inner barrier layer. Impedance values of barrier layer were higher than porous layer. Corrosion resistance of specimens decreased at high fluoride concentrations and at low pH of artificial saliva. Corrosion resistance of alloys was slightly decreased with aging. Mechanical properties, microstructure, and surface roughness of the specimens were also examined.
Gujjari, Anil K; Bhatnagar, Vishrut M; Basavaraju, Ravi M
2013-01-01
To evaluate the color stability and flexural strength of poly (methyl methacrylate) (PMMA) and bis-acrylic composite based provisional crown and bridge auto-polymerizing resins exposed to tea, coffee, cola, and food dye. Two provisional crown and bridge resins, one DPI self-cure tooth molding powder (PMMA) (Group A), and one Protemp 4 Temporization Material (bis-acrylic composite) (Group B) were used. Disk-shaped specimens for color stability testing (n = 30 for each material) and bar-shaped specimens for flexural strength testing (n = 30 for each material) were fabricated using a metal mold. The specimens were immersed in artificial saliva, artificial saliva + tea, artificial saliva + coffee, artificial saliva + cola, and artificial saliva + food dye solutions and stored in an incubator at 37°C. Color measurements were taken before immersion, and then after 3 and 7 days of immersion. Flexural strength was evaluated after 7 days of immersion. Group A showed significantly higher color stability as compared to Group B, and artificial saliva + coffee solution had the most staining capacity for the resins. Test solutions had no effect on the flexural strength of Group A, but Group B specimens immersed in artificial saliva + cola showed significantly lower flexural strength values as compared to the control group. The findings of the study showed that for materials used in the study, PMMA was more color stable than bis-acrylic composite based resin. Also, material based on PMMA was more resistant to damage from dietary beverages as compared to bis-acrylic composite based provisional crown and bridge resin.
Effects of fluoridated milk on root dentin remineralization.
Arnold, Wolfgang H; Heidt, Bastian A; Kuntz, Sebastian; Naumova, Ella A
2014-01-01
The prevalence of root caries is increasing with greater life expectancy and number of retained teeth. Therefore, new preventive strategies should be developed to reduce the prevalence of root caries. The aim of this study was to investigate the effects of fluoridated milk on the remineralization of root dentin and to compare these effects to those of sodium fluoride (NaF) application without milk. Thirty extracted human molars were divided into 6 groups, and the root cementum was removed from each tooth. The dentin surface was demineralized and then incubated with one of the following six solutions: Sodium chloride NaCl, artificial saliva, milk, milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Serial sections were cut through the lesions and investigated with polarized light microscopy and quantitative morphometry, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). The data were statistically evaluated using a one-way ANOVA for multiple comparisons. The depth of the lesion decreased with increasing fluoride concentration and was the smallest after incubation with artificial saliva+10 ppm fluoride. SEM analysis revealed a clearly demarcated superficial remineralized zone after incubation with milk+2.5 ppm fluoride, milk+10 ppm fluoride and artificial saliva+10 ppm fluoride. Ca content in this zone increased with increasing fluoride content and was highest after artificial saliva+10 ppm fluoride incubation. In the artificial saliva+10 ppm fluoride group, an additional crystalline layer was present on top of the lesion that contained elevated levels of F and Ca. Incubation of root dentin with fluoridated milk showed a clear effect on root dentin remineralization, and incubation with NaF dissolved in artificial saliva demonstrated a stronger effect.
NASA Astrophysics Data System (ADS)
Farahdillah; Triaminingsih, S.; Eriwati, Y. K.
2017-08-01
The aim of this study was to analyze the effect of salivary pH to diametral tensile strength of glass ionomer cement (GIC) coated with a coating agent. GIC specimens coated with varnish and nano-filled coating agent were stored in artificial saliva at pH values of 4.5, 5.5, and 7 for 24 h at 37°C, then the diametral tensile strength was tested by universal testing machine. Results showed that there was no significant difference in the diametral tensile strength of the GIC coated with varnish and nano-filled coating agent with decreasing of salivary pH (p < 0.05). It can be concluded that salivary pH does not affect the diametral tensile strength of GIC coated by varnish or nano-filled coating agent
Effects of Peracetic Acid on the Corrosion Resistance of Commercially Pure Titanium (grade 4).
Raimundo, Lariça B; Orsi, Iara A; Kuri, Sebastião E; Rovere, Carlos Alberto D; Busquim, Thaís P; Borie, Eduardo
2015-01-01
The aim of this study was to evaluate the corrosion resistance of pure titanium grade 4 (cp-Ti-4), subjected to disinfection with 0.2% and 2% peracetic acid during different immersion periods using anodic potentiodynamic polarization test in acid and neutral artificial saliva. Cylindrical samples of cp-Ti-4 (5 mm x 5 mm) were used to fabricate 24 working electrodes, which were mechanically polished and divided into eight groups (n=3) for disinfection in 2% and 0.2% peracetic acid for 30 and 120 min. After disinfection, anodic polarization was performed in artificial saliva with pH 4.8 and 6.8 to assess the electrochemical behavior of the electrodes. A conventional electrochemical cell, constituting a reference electrode, a platinum counter electrode, and the working electrode (cp-Ti specimens) were used with a scanning rate of 1 mV/s. Three curves were obtained for each working electrode, and corrosion was characterized by using scanning electron microscopy (SEM) and energy dispersive x-ray spectrometry (EDS). Data of corrosion potential (Ecorr) and passive current (Ipass) obtained by the polarization curves were analyzed statistically by Student's t-test (a=0.05). The statistical analysis showed no significant differences (p>0.05) between artificial saliva types at different concentrations and periods of disinfection, as well as between control and experimental groups. No surface changes were observed in all groups evaluated. In conclusion, disinfection with 0.2% and 2% peracetic acid concentrations did not cause corrosion in samples manufactured with cp-Ti-4.
Effects of sucking acidic candy on whole-mouth saliva composition.
Jensdottir, T; Nauntofte, B; Buchwald, C; Bardow, A
2005-01-01
Limited information is available on the effects of sucking acidic candies on saliva composition and the protective role of saliva in this relation. Therefore the aim of this study was to determine salivary effects of sucking acidic candies in vivo in relation to individual variations in whole-saliva flow rate (WSFR) and buffer capacity (WSbeta). Ten healthy young males (24 +/- 2 years) sucked a rhubarb-flavoured acidic hard-boiled candy with tartaric acid available on the Danish market. The whole saliva was collected into a closed system, regarding CO2, at different times as follows: firstly, unstimulated saliva for 5 min (baseline), secondly stimulated saliva for 4 min upon sucking the candy, and finally post-stimulated saliva for 10 min. Saliva pH was determined on a blood gas analyser and WSbeta was estimated from the saliva bicarbonate concentration obtained by the analyser and by ionic balance calculation. The erosive potential of the candy in saliva was estimated from the saliva pH values and degree of saturation with respect to hydroxyapatite (DS(HAp)). The results showed that saliva pH dropped from 6.5 (baseline) down to 4.5 at the fourth minute of sucking the candy, and returned to pH 6.5 five minutes after stimulation (post-stimulated). DS(HAp) decreased upon sucking the candy and saliva from all subjects became undersaturated with respect to HAp. Significant positive correlations were obtained between pH and WSFR (r(s) = 0.47; p < 0.05) and between pH and WSbeta (r(s) = 0.65; p < 0.01). In relation to WSbeta we found that 70% of the buffer capacity originating from the bicarbonate buffer system upon sucking the candy was exerted as phase buffering. We conclude that sucking this type of acidic candies changes whole-mouth saliva composition so that it may have erosive potential and that high WSFR and WSbeta have protective effects against these salivary changes. Copyright 2005 S. Karger AG, Basel.
Zundel, J; Ansari, S A; Trivedi, H M; Masters, J G; Mascaro, S
2018-05-07
The purpose of this research is to characterize the effects of mouthwash solutions on oral friction and moisture using a quantitative in vitro approach. The frictional coefficient of in vitro porcine tongue samples was measured using a magnetic levitation haptic device equipped with a custom tactor designed to mimic human skin. A commercially available moisture meter was used to measure moisture content of the samples. Tongue samples were first tested before treatment, then after application of saliva (either human or artificial), and again after application of 1 of 11 different mouthwash solutions. The data indicate that the samples treated with artificial saliva vs real saliva have comparable friction coefficient and moisture content. Furthermore, the moisture and friction coefficient remain relatively constant for up to 60 minutes after exposure to ambient conditions. Samples treated with artificial saliva have an average friction coefficient in the range of 0.70-0.80. Application of mouthwash solutions produced an average friction coefficient of 0.39-0.49 but retained the high moisture content of the artificial salivary layer. Several mouthwash solutions resulted in statistically significant differences in the friction coefficient relative to each other. The results of this study demonstrate that a magnetic levitation device can be an effective tool for in vitro oral tribology and that artificial saliva is an effective substitute for real saliva in extended in vitro experiments. The application of mouthwash generally reduces the coefficient of friction of the tongue samples while preserving a relatively high moisture level, and some mouthwashes reduce friction significantly more than others. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Xylitol concentrations in artificial saliva after application of different xylitol dental varnishes
PEREIRA, Agnes de Fátima Faustino; da SILVA, Thiago Cruvinel; da SILVA, Thelma Lopes; CALDANA, Magali de Lourdes; BASTOS, José Roberto Magalhães; BUZALAF, Marília Afonso Rabelo
2012-01-01
Objective The present study analyzed xylitol concentrations in artificial saliva over time after application of varnishes containing 10% and 20% xylitol. Material and Methods Fifteen bovine enamel specimens (8x4 mm) were randomly allocated to 3 groups (n=5/group), according to the type of varnish used: 10% xylitol, 20% xylitol and no xylitol (control). After varnish application (4 mg), specimens were immersed in vials containing 500 µL of artificial saliva. Saliva samples were collected in different times (1, 8, 12, 16, 24, 48 and 72 h) and xylitol concentrations were analyzed. Data were assessed by two-way repeated-measures ANOVA (p<0.05). Results Colorimetric analysis was not able to detect xylitol in saliva samples of the control group. Salivary xylitol concentrations were significantly higher up to 8 h after application of the 20% xylitol varnish. Thereafter, the 10% xylitol varnish released larger amounts of that polyol in artificial saliva. Conclusions Despite the results in short-term, sustained xylitol releases could be obtained when the 10% xylitol varnish was used. These varnishes seem to be viable alternatives to increase salivary xylitol levels, and therefore, should be clinically tested to confirm their effectiveness. PMID:22666828
Navarro, M; Pichini, S; Farré, M; Ortuño, J; Roset, P N; Segura, J; de la Torre, R
2001-10-01
Saliva is an alternative biologic matrix for drugs-of-abuse testing that offers the advantages of noninvasive, rapid, and easy sampling. We studied the excretion profile of 3,4-methylenedioxymethamphetamine (MDMA) and its metabolites in both saliva and plasma, as well the effect of the drug on salivary pH. Saliva and plasma samples were obtained from eight healthy MDMA consumers after ingestion of a single 100-mg dose of the drug. Concentrations of MDMA and its main metabolites, 3,4-methylenedioxyamphetamine (MDA) and 4-hydroxy-3-methoxymethamphetamine (HMMA), in saliva and plasma were measured by gas chromatography-mass spectrometry. Apparent pharmacokinetic parameters for MDMA in saliva were estimated, and the saliva-to-plasma ratio at each time interval was calculated and correlated with salivary pH. MDMA, MDA, and HMMA were detected in saliva. Salivary concentrations of MDMA were 1728.9-6510.6 microg/L and peaked at 1.5 h after drug intake. This was followed by a progressive decrease, with a mean concentration of 126.2 microg/L at 24 h. The saliva-to-plasma ratio was 32.3-1.2, with a peak of 18.1 at 1.5 h after drug administration. Salivary pH seemed to be affected by MDMA administration; pH values decreased by 0.6 units (mean pH values of 6.9 and 6.8 at 1.5 and 4 h after drug administration vs predose pH of 7.4). Measurement of MDMA in saliva is a valuable alternative to determination of plasma drug concentrations in both clinical and toxicologic studies. On-site testing is also facilitated by noninvasive and rapid collection of salivary specimens.
Nakonieczna-Rudnicka, Marta; Bachanek, Teresa; Rogowska, Wanda
2009-01-01
Dental decay is a pathological process of extrasomatic origin which leads to demineralization and proteolytic degradation of hard surfaces of a tooth susceptible to this disease. Saliva composition, including calcium ion concentration and its pH value, is of importance in the development of the carious process. Tobacco smoke contains toxic compounds which negatively influence oral health. The aim of the study was evaluation of the selected saliva components: protein concentration, Ca2+ concentration, pH value both in male and female smokers. The investigated group included 65 patients reporting for the treatment to the Department of Conservative Dentistry of Medical University in Lublin. In the investigated group male smokers constituted 15.38%, female smokers--20.00%, male nicotine abstinents 21.54% and female nicotine abstinent 43.08%. The study included both survey examinations of patients and biochemical examinations of the saliva. Mixed, non-stimulated saliva was used as a material for biochemical examinations. Ca2+ concentration and pH of the saliva were assayed with the use of Rapidlab 348 analyzer. Protein in the saliva was assayed with calorimetric method according to Lowry. Saliva was collected from smokers 10-120 minutes after smoking of several cigarettes. It was stated that Ca2+ and protein concentration as well as pH of the saliva were not correlated with sex and cigarette smoking or non-smoking.
Pimentel, Roberta Ferreira; de Oliveira, Roberto Sotto Maior Fortes; Chaves, Maria das Graças Afonso Miranda; Elias, Carlos Nelson; Gravina, Marco Abdo
2013-01-01
To evaluate and compare "in vitro" the maximum friction force generated by three types of esthetic brackets, two types of polycrystalline conventional ceramic brackets (20/40 and InVu) and one type of sapphire monocrystalline bracket (Radiance) in dry and artificial saliva wet settings. Also, to evaluate the influence exerted by artificial saliva on the friction forces of those brackets. Tests were performed in dry and artificial saliva wet setting (Oral Balance) by using an EMIC DL 10000 testing machine, simulating a 2 mm slide of 0.019 x 0.025-in rectangular stainless steel wires over the pre-angulated and pre-torqued (right superior canine, Roth prescription, slot 0.022 x 0.030-in) brackets (n = 18 for each bracket). In order to compare groups in dry and wet settings, the ANOVA was used. For comparisons related to the dry versus wet setting, the student t test was used for each group. The results showed that in the absence of saliva the Radiance monocrystalline brackets showed the highest friction coefficients, followed by the 20/40 and the InVu polycrystalline brackets. In tests with artificial saliva, the Radiance and the 20/40 brackets had statistically similar friction coefficients and both were greater than that presented by the InVu brackets. The artificial saliva did not change the maximum friction force of the Radiance brackets, but, for the others (20/40 and InVu), an increase of friction was observed in its presence. The InVu brackets showed, in the absence and in the presence of saliva, the lowest friction coefficient.
The influence of storage time and pH variation on water sorption by different composite resins.
Gusmão, George Mário de Araújo Silva; De Queiroz, Thiago Vinicius Veras; Pompeu, Guilherme Ferrer; Menezes Filho, Paulo Fonseca; da Silva, Cláudio Heliomar Vicente
2013-01-01
The objective of this work was to assess the influence of storage time and pH cycling on water sorption by different composite resins. Nine resin brands were selected and divided into groups: G1-ROK (SDI), G2-ICE (SDI), G3-GLACIER (SDI), G4-Z350 (3M/ESPE), G5-Z250 (3M/ESPE), G6-TPH 3 (DENTSPLY), G7-ESTHET X (DENTSPLY), G8-SUPRAFILL (SSWHITE), and G9-MASTERFILL (BIODINΒMICS). Ninety specimens, ten per group, were obtained using an aluminum matrix. Specimens measured 10 mm diameter × 2 mm width. The groups were divided into subgroups according to the immersion solution: A - control (n = 05) stored in artificial saliva pH = 7.0 and B-test (n = 05) submitted to seven consecutive days of pH cycling (cariogenic challenger) that consisted of immersion in a pH° = 4.3 solution for 6 h followed by immersion in a pH¹ =7.0 solution for 18 h and stored in artificial saliva pH = 7.0 until the end of the experiment. The specimens were weighed on six occasions: T 0 (after fabrication), T 1 (24 h), T 2 (7 days), T 3 (15 days), T 4 (30 days), T 5 (60 days), and then analyzed. The water sorption was determined by the weight difference between the specimens at the time intervals. The mean weight gain was exactly the same for both the subgroups within group G4. The highest means for the control subgroup were found in groups: G1, G5, G7, G8, and G9. For the pH cycling subgroup, the highest means were found in G2, G3, and G6; however, significant differences between the subgroups compared to the mean-weight gain were found for G1, G5, and G7. The water sorption of composite resins is dependent upon their storage time. The pH cycling created a significant impact on resins G1, G5, and G7. The sorption and solubility of composite resins vary according to their chemical composition.
Vuletic, Lea; Peros, Kristina; Spalj, Stjepan; Rogic, Dunja; Alajbeg, Ivan
2014-01-01
To quantify changes in pH, buffering capacity and hydrogen carbonate, phosphate, protein and urea concentrations of stimulated saliva which occur during a 30-min measurement delay after saliva collection. The correlation between time-related chemical changes and changes of salivary pH and buffering capacity was assessed in order to explain the observed changes in salivary pH and buffering capacity. Stimulated saliva samples were collected from 30 volunteers after inducing salivation by chewing a piece of parafilm. Measurements of salivary variables were made immediately after saliva collection and again 30 min later, during which time the specimens were exposed to the atmosphere in collection cups at room temperature. Postponement of measurements resulted in a significant increase in pH and a significant decrease of buffering capacity, phosphate and urea concentration. The results suggest that the time-related pH increase could primarily be attributed to loss of dissolved carbon dioxide from saliva, and confirm the importance of hydrogen carbonate in the neutralisation of hydrogen ions, but they do not support the principle of catalysed phase-buffering for the hydrogen carbonate buffer system in saliva. A decrease in phosphate and urea concentration affects salivary buffering capacity. This study emphasises the importance of the standardisation of measurement time when measuring salivary pH, buffering capacity, phosphate and urea concentrations following the collection of saliva in order to obtain comparable results. It also provides a partial explanation of the mechanisms underlying the observed changes of pH and buffering capacity over time.
Garg, Aditi; Shenoy, K Kamalakanth
2016-01-01
Soft denture liners have a key role in modern removable prosthodontics since they restore health to inflamed and abused mucosa by redistribution of forces transmitted to the edentulous ridges. The most common problems encountered using soft denture liners are water sorption and solubility when in contact with saliva or storage media. These problems are associated with swelling, distortion, support of Candida albicans growth, and stresses at the liner/denture base interface that reduces the bond strength. To evaluate the water sorption and solubility of commercially available acrylic based self cure soft denture lining material (GC RELINE™ Tissue Conditioner) after immersion in three different storage media (distilled water, Shellis artificial saliva, 5.25% sodium hypochlorite disinfectant solution) at time interval of 4, 7, 11, and 15 days. The study involved preparation of artificial saliva using Shellis formula. A total 45 standardized samples of the material (GC RELINE™) were prepared in disk form (15 mm in diameter and 2 mm in thickness). The study was divided into three groups with storage in Control (distilled water), Shellis artificial saliva, and 5.25% sodium hypochlorite. Samples were dried in a desiccator and weighed in the analytical balance to measure the initial weight (mg/cm2) of the disks (W1). The first groups (15 samples) were placed in 30 ml distilled water (Group A) at 37ºC, second group 30 ml of artificial saliva (Group B) and third group in 5.25% sodium hypochlorite (Group C). Disks were removed from disinfectant after 5 min and placed in 30 ml distilled water. On days 4, 7, 11, and 15, all samples were removed from their containers and reweighed to measure the weight (mg/cm2) of the disks after sorption (W2). The solubility was measured by placing the disks back in the desiccator after each sorption cycle and drying them to constant weight in the desiccator. These values were weight after desiccation (W3). Water sorption and solubility was calculated: 1. Sorption (mg/cm2) = (W2-W1)/Surface area 2. Solubility (mg/cm2) = (W1-W3)/Surface area. Statistical Analysis was done using one way analysis of variance and the intercomparison between each group was done using Tukey's honestly significance difference (HSD) test. Within the limitations of this study it was concluded that water sorption of the GC RELINE™ soft denture liner material was highest in distilled water followed by 5.25% sodium hypochlorite and least in Shellis artificial saliva at 4, 7, and 11 day interval. However, on the 15th day, the results showed maximum water sorption in 5.25% sodium hypochlorite followed by distilled water and least in artificial saliva. The results on solubility showed highest solubility of GC RELINE soft denture liner in artificial saliva followed by distilled water and least in 5.25% sodium hypochlorite at 4, 7, 11, and 15 day interval. The least water uptake of the soft liner in artificial saliva was due to its ionic properties and supports the theory that water uptake of these materials is osmotically driven. However, the solubility was highest in artificial saliva since it is a mix of various salts and other additives, so there is a possibility of interaction with soft denture lining material.
NASA Astrophysics Data System (ADS)
Liu, Jia-Kuang; Liu, I.-Hua; Liu, Cheng; Chang, Chen-Jung; Kung, Kuan-Chen; Liu, Yen-Ting; Lee, Tzer-Min; Jou, Jin-Long
2014-10-01
The purpose of this investigation was to develop titanium nitride (TiN)/titanium (Ti) coating on orthodontic nickel-titanium (NiTi) wires and to study the stress corrosion of specimens in vitro, simulating the intra-oral environment in as realistic a manner as possible. TiN/Ti coatings were formed on orthodontic NiTi wires by physical vapor deposition (PVD). The characteristics of untreated and TiN/Ti-coated NiTi wires were evaluated by measurement of corrosion potential (Ecorr), corrosion current densities (Icorr), breakdown potential (Eb), and surface morphology in artificial saliva with different pH and three-point bending conditions. From the potentiodynamic polarization and SEM results, the untreated NiTi wires showed localized corrosion compared with the uniform corrosion observed in the TiN/Ti-coated specimen under both unstressed and stressed conditions. The bending stress influenced the corrosion current density and breakdown potential of untreated specimens at both pH 2 and pH 5.3. Although the bending stress influenced the corrosion current of the TiN/Ti-coated specimens, stable and passive corrosion behavior of the stressed specimen was observed even at 2.0 V (Ag/AgCl). It should be noted that the surface properties of the NiTi alloy could determine clinical performance. For orthodontic application, the mechanical damage destroys the protective oxide film of NiTi; however, the self-repairing capacity of the passive film of NiTi alloys is inferior to Ti in chloride-containing solutions. In this study, the TiN coating was found able to provide protection against mechanical damage, while the Ti interlayer improved the corrosion properties in an aggressive environment.
NASA Astrophysics Data System (ADS)
Gunawarman; Giatmana, D. D.; Ilhamdi; Affi, J.; Fonna, S.; Niinomi, M.; Nakai, M.
2018-05-01
The corrosion resistance of Ti-29Nb-13Ta-4.6Zr (TNTZ) and Ti-6Al-4V alloys in oral cavity environment were studied by investigating its corrosion rate in artificial saliva solution. Corrosion measurement was conducted in 600 ml solution of Fusayama-Meyer artificial saliva containing 0.4g NaCl, 0.4g KCl, 0.795g CaCl2.2H2O, 0.69g NaH2PO4, and 1 g urea using a potentiostat controlled by a personal computer. The solution was maintained at pH 5.2 and controlled the temperature of 37°C to imitate oral cavity condition. After corrosion test, specimen surfaces were examined by SEM and EDX. The results show that the average corrosion rate of TNTZ and Ti-6Al-4V is 4,5×10-9 mmy-1 and 6,4×10-8 mmy-1, respectively, indicating that the corrosion resistance of TNTZ is slightly better than Ti-6Al-4V. This is suggested mainly due to the formation of multiple layers of Ti, Nb and Zr oxides in the surface of TNTZ. However, the formation of micro-pitting corrosion is more severe in TNTZ as compared to that of Ti-6Al-4V. The intense pitting corrosion in TNTZ is found strongly corresponded to its high impurities content and wide elemental segregation. It is recommended, therefore, a longer homogenizing process is required in TNTZ for reducing pitting corrosion attack. However, the details of corrosion mechanism are needed to be explored further.
Ardlin, Berit I; Lindholm-Sethson, Britta; Dahl, Jon E
2009-02-01
To study corrosion and to evaluate biological effects in vitro of corrosion products of a copper-aluminum-nickel alloy with 2% gold. The alloy NPGtrade mark+2 with the nominal composition Cu:77.3; Al:7.8; Ni:4.3; Fe:3.0; Zn:2.7; Au:2.0; and Mn:1.7 was characterized. Static immersion in acidic saline, pH 2.2-2.4, was used to determine release of metallic elements in a milieu simulating the condition of plaque build-up in interproximal areas of the tooth. Corrosion and surface reactions in saline and artificial saliva were studied by electrochemical techniques including registration of open-circuit-potentials, polarization curves and impedance spectra. Extracts were made in cell culture media and acidic saline and used for MTT test for cytotoxicity and HET-CAM method for irritation. The mean amount of elements released in the acidic saline were in microg cm(-2) : Cu:632; Al:210; Ni:144; Fe:122; Zn:48; Mn:52. No protective film was formed on the surface of the alloy, as extensive corrosion was observed in both saline and artificial saliva. The corrosion rate was higher in saline than in artificial saliva. Acidic extracts of the alloy diluted up to 64 times reduced cell viability with 80% or more. The extract induced coagulation of the blood vessels of the CAM and was rated as moderate irritant solution. The nickel-aluminum bronze showed high corrosion rate caused by an inability to create a protective surface layer. High levels of toxic elements were found after static immersion testing, and the corrosion products had a distinct adverse effect on the biological activity. Copyright 2008 Wiley Periodicals, Inc.
Qiao, Guang-yan; Zhang, Li-xia; Wang, Jue; Shen, Qing-ping; Su, Jian-sheng
2014-08-01
To investigate the effect of epigallocatechin gallate (EGCG) on the surface properties of nickel-chromium dental alloys after electrochemical corrosion. The surface morphology and surface structure of nickel-chromium dental alloys were examined by stereomicroscope and scanning electron microscopy before and after electrochemical tests in 0 g/L and 1.0 g/L EGCG artificial saliva. The surface element component and chemical states of nickel-chromium dental alloys were analyzed by X-ray photoelectron spectrograph after electrochemical tests in 0 g/L and 1.0 g/L EGCG artificial saliva. More serious corrosion happened on the surface of nickel-chromium alloy in 1.0 g/L EGCG artificial saliva than in 0 g/L EGCG. The diameters of corrosion pits were smaller, and the dendrite structure of the alloy surface was not affected in 0 g/L EGCG. While the diameters of corrosion pits were larger, the dendritic interval of the alloy surface began to merge, and the dendrite structure was fuzzy in 1.0 g/L EGCG. In addition, the O, Ni, Cr, Be, C and Mo elements were detected on the surface of nickel-chromium alloys after sputtered for 120 s in 0 g/L EGCG and 1.0 g/L EGCG artificial saliva after electrochemical corrosion, and the surface oxides were mainly NiO and Cr(2)O(3). Compared with 0 g/L EGCG artificial saliva, the content of O, NiO and Cr(2)O(3) were lower in 1.0 g/L EGCG. The results of surface morphology and the corrosion products both show that the corrosion resistance of nickel-chromium alloys become worse and the oxide content of corrosion products on the surface reduce in 1.0 g/L EGCG artificial saliva.
Influence of Soft Drinks with Low pH on Different Ni-Ti Orthodontic Archwire Surface Patterns
NASA Astrophysics Data System (ADS)
Abalos, C.; Paul, A.; Mendoza, A.; Solano, E.; Palazon, C.; Gil, F. J.
2013-03-01
The aim of this study was to determine the influence of soft drinks on the surface of Ni-Ti archwires and their corrosion behavior. Archwires with different patterns (smooth, scratch, dimple, and crack) were selected and characterized by scanning electron microscopy and laser confocal microscopy. Immersion tests were performed in artificial saliva (pH 6.7) with a soft drink with a pH of 2.5 for 28 days. The results showed an increase in the surface defects and/or roughness of the dimple, crack and scratch patterns with the immersion times, and a decrease in corrosion resistance. A relationship between the surface pattern and the extent of the corrosion in Ni-Ti archwires with soft drinks at low pH has been demonstrated. Pattern should be taken into account in future studies, and manufacturing processes that produce surface defects (especially cracks) should be avoided.
Gupta, Gaurav; Gupta, Tina
2011-07-01
THIS STUDY EVALUATED THE COLOR STABILITY OF FOUR PROVISIONAL MATERIALS: 1) Poly-methyl methacrylates (DPI); 2) Bis-acryl composite (ProtempTM II - 3M ESPE); 3) Bis-acryl composite (Systemp® c and b - Ivoclar Vivadent) and 4) Light polymerized composite resin (Revotek LC- GC). The color and color difference of each specimen after immersion in different staining solutions i.e. 1) tea and artificial saliva, 2) coffee and artificial saliva, 3) Pepsi and artificial saliva, 4) turmeric solution and artificial saliva was measured using reflectance spectrophotometer with CIELAB system before immersion and after immersion at 2, 5 ,7 , 10 and 15 days. Revotek LC- GC (light polymerized composite resin) was found to be the most color stable provisional restorative material followed by Protemp II (Bis-acryl composite), Systemp (Bis-acryl composite) and DPI (Methylmethacrylate resin). Turmeric solution had the maximum staining potential followed by coffee, tea and Pepsi.
Gupta, Gaurav; Gupta, Tina
2011-01-01
Aim: This study evaluated the color stability of four provisional materials: 1) Poly-methyl methacrylates (DPI); 2) Bis-acryl composite (ProtempTM II – 3M ESPE); 3) Bis-acryl composite (Systemp® c and b – Ivoclar Vivadent) and 4) Light polymerized composite resin (Revotek LC- GC). Materials and Methods: The color and color difference of each specimen after immersion in different staining solutions i.e. 1) tea and artificial saliva, 2) coffee and artificial saliva, 3) Pepsi and artificial saliva, 4) turmeric solution and artificial saliva was measured using reflectance spectrophotometer with CIELAB system before immersion and after immersion at 2, 5 ,7 , 10 and 15 days. Results: Revotek LC- GC (light polymerized composite resin) was found to be the most color stable provisional restorative material followed by Protemp II (Bis-acryl composite), Systemp (Bis-acryl composite) and DPI (Methylmethacrylate resin). Turmeric solution had the maximum staining potential followed by coffee, tea and Pepsi. PMID:22025835
Nanjundan, Kavitha; Vimala, G
2016-01-01
To evaluate the changes of static and kinetic frictional forces between the brackets and wires following exposure to a soft drink, acidic food ingredient, and acidulated fluoride prophylactic agents. Two types of Roth prescription mandibular incisor brackets were used: 3M Unitek Victory stainless steel (SS) brackets (n = 40) and Transcend 6000 polycrystalline alumina (PCA) brackets (n = 40) as well as eighty 0.019 × 0.025" dimension ortho technology SS wires of 50 mm length each. Subsequently, brackets tied with SS wires divided into eight subgroups (n = 10) and were immersed in vinegar (pH = 3.5 ± 0.5), Pepsi ® (pH = 2.46), Colgate Phos-Flur mouth rinse (pH = 5.1), and artificial saliva (control group pH = 7) for 24 h. Changes in surface morphology under scanning electron microscope ×1000, surface roughness (Ra) with surface profilometer (single bracket and single wire from each subgroup), and frictional resistance using universal testing machine were evaluated. Highest mean (standard deviation) static frictional force of 2.65 (0.25) N was recorded in Pepsi ® followed by 2.57 (0.25) N, 2.40 (0.22) N, and 2.36 (0.17) N for Vinegar, Colgate Phos-Flur mouth rinse, and artificial saliva groups, respectively. In a similar order, lesser mean kinetic frictional forces obtained. PCA brackets revealed more surface deterioration and higher frictional force values than SS brackets. A significant positive correlation was observed between frictional forces and bracket slot roughness (r = 0.861 and 0.802, respectively, for static and kinetic frictional forces, p < 0.001 for both) and wire roughness (r = 0.243 and 0.242, respectively, for static and kinetic frictional forces, p < 0.05 for both). Findings may have long-term implications when acidic food substances are used during fixed orthodontic treatment. Further, in vivo studies are required to analyze the clinical effect of acidic mediums in the oral environment during orthodontic treatment.
Improved artificial saliva for studying the cariogenic effect of carbohydrates.
Björklund, Marika; Ouwehand, Arthur C; Forssten, Sofia D
2011-07-01
Saliva is a complex fluid that possesses many important functions regarding oral health. Many in vitro studies require relatively large quantities of saliva. While natural saliva would be the material of choice, it is difficult to obtain in sufficient quantities and varies in composition. Substitutes mimicking the physicochemical properties of saliva have been developed, but these are not appropriate to study the growth of mutans streptococci. Brain Heart Infusion (BHI) has been commonly used for this, but this medium is richer in nutrients than saliva. We therefore developed artificial saliva (AS) with nutrient levels resembling those in natural saliva as a substitute for natural human saliva (HS) to study the influence of different carbon sources on mutans streptococci growth. Growth of a wild-type Streptococcus mutans strain and S. mutans ATCC 15175 in BHI, HS, and AS was monitored anaerobically. Growth of S. mutans in the modified AS was very similar to the growth in HS, both in the absence and presence of different carbon sources. We therefore conclude that the developed AS is suitable for in vitro tests on S. mutans growth.
Are salivary amylase and pH - Prognostic indicators of cancers?
Ramya, Atmakuri Shanmukha; Uppala, Divya; Majumdar, Sumit; Surekha, Ch; Deepak, K G K
2015-01-01
Saliva, "Mirror of body's health" has long been of particular interest as a substitute for blood for disease diagnosis and monitoring. The radiation effects on salivary glands are of particular interest in which salivary amylase is a good indicator of salivary glands function. Thus, estimation of these parameters represents a reasonable approach in evaluation of patient's risk for disease occurrence, intensity and prognosis. To evaluate and compare the pH and amylase levels in saliva of cancer patients prior to treatment, patients during treatment. Saliva samples of 90 individuals were taken which were divided into 3 groups - 30 individuals without cancer, 30 cancer patients prior treatment and 30 cancer patients during treatment. Materials used were pH strips and pH meter, Salivary Amylase assay. Statistical analysis - ANOVA with post-hoc Tukey's test. 1) Significant decrease in salivary amylase levels - in cancer patients, during treatment when compared to others. 2) Significant decrease in salivary pH levels in newly diagnosed cancer patients prior to treatment. To conclude, pH strips and pH meter showed to be a useful tool in the measurement of pH of saliva in individuals with and without cancer. This study showed that cancer patients without treatment have a lower pH of saliva. Treatment increased the pH of the saliva to a more alkaline level whereas amylase levels decreased in those subjects. Therefore those parameters can be an area of further research with an increased sample size, which in-turn may help in opening the doors for new dimension in non invasive prognostic markers.
Milošev, Ingrid; Kapun, Barbara; Selih, Vid Simon
2013-01-01
Metallic materials used for manufacture of dental implants have to exhibit high corrosion resistance in order to prevent metal release from a dental implant. Oral cavity is aggressive towards metals as it represents a multivariate environment with wide range of conditions including broad range of temperatures, pH, presence of bacteria and effect of abrasion. An increasing use of various Ti-based materials for dental implants and orthodontic brackets poses the question of their corrosion resistance in the presence of fluoride ions which are present in toothpaste and mouth rinse. Corrosion behaviour of Ti metal, Ti-6Al-7Nb and Ti-6Al-4V alloys and constituent metals investigated in artificial saliva is significantly affected by the presence of fluoride ions (added as NaF), as proven by electrochemical methods. Immersion test was performed for 32 days. During that time the metal dissolution was measured by inductively coupled plasma mass spectrometry. At the end of the test the composition, thickness and morphology of the surface layers formed were investigated by X-ray photoelectron spectroscopy and scanning electron microscopy.
Role of lubricants on friction between self-ligating brackets and archwires.
Leal, Renata C; Amaral, Flávia L B; França, Fabiana M G; Basting, Roberta T; Turssi, Cecilia P
2014-11-01
To evaluate the effect of different lubricants on friction between orthodontic brackets and archwires. Active (Quick, Forestadent) and passive (Damon 3MX, Ormco) self-ligating brackets underwent friction tests in the presence of mucin- and carboxymethylcellulose (CMC)-based artificial saliva, distilled water, and whole human saliva (positive control). Dry friction (no lubricant) was used as the negative control. Bracket/wire samples (0.014 × 0.025 inch, CuNiTi, SDS Ormco) underwent friction tests eight times in a universal testing machine. Two-way analysis of variance showed no significant interaction between bracket type and lubricant (P = .324). Friction force obtained with passive self-ligating brackets was lower than that for active brackets (P < .001). Friction observed in the presence of artificial saliva did not differ from that generated under lubrication with natural human saliva, as shown by Tukey test. Higher friction forces were found with the use of distilled water or when the test was performed under dry condition (ie, with no lubricant). Lubrication plays a role in friction forces between self-ligating brackets and CuNiTi wires, with mucin- and CMC-based artificial saliva providing a reliable alternative to human natural saliva.
Liu, Cong; Zhang, Erlin
2015-03-01
Ti-10Cu sintered alloy has shown strong antibacterial properties against S. aureus and E. coli and good cell biocompatibility, which displays potential application in dental application. The corrosion behaviors of the alloy in five different simulated biological solutions have been investigated by electrochemical technology, surface observation, roughness measurement and immersion test. Five different simulated solutions were chosen to simulate oral condition, oral condition with F(-) ion, human body fluids with different pH values and blood system. It has been shown that Ti-10Cu alloy exhibits high corrosion rate in Saliva pH 3.5 solution and Saliva pH 6.8 + 0.2F solution but low corrosion rate in Hank's, Tyrode's and Saliva pH 6.8 solutions. The corrosion rate of Ti-10Cu alloy was in a order of Hank's, Tyrode's, Saliva pH 6.8, Saliva-pH 3.5 and Saliva pH 6.8 + 0.2F from slow to fast. All results indicated acid and F(-) containing conditions prompt the corrosion reaction of Ti-Cu alloy. It was suggested that the Cu ion release in the biological environments, especially in the acid and F(-) containing condition would lead to high antibacterial properties without any cell toxicity, displaying wide potential application of this alloy.
Nanjannawar, Lalita Girish; Girme, Tejashree Suresh; Agrawal, Jiwanasha Manish; Agrawal, Manish Suresh; Fulari, Sangamesh Gurunath; Shetti, Shraddha Subhash; Kagi, Vishwal Ajith
2017-09-01
Hand held mobile phones are presently the most popular means of communication worldwide and have transformed our lives in many aspects. The widespread use of such devices have resulted in growing concerns regarding harmful effects of radiations emitted by them. This study was designed to evaluate the effects of mobile phone usage on nickel ion release as well as pH of saliva in patients with fixed orthodontic appliances. To assess the level of nickel ions in saliva and pH of saliva in mobile phone users undergoing fixed orthodontic treatment using inductively coupled plasma atomic emission spectrometry. A total of 42 healthy patients with fixed orthodontic appliance in mouth for a duration of six to nine months were selected for the study. They were divided into experimental group (n=21) consisting of mobile phone users and control group (n=21) of non mobile phone users. Saliva samples were collected from both the groups and nickel ion levels were measured using inductively coupled plasma-mass spectroscopy. The pH values were also assessed for both groups using pH meter. Unpaired t-test was used for the data analysis. Statistical analysis revealed that though the pH levels were reduced and the nickel ion levels were higher in the experimental group compared to the control group, the results were non significant. Mobile phone usage may affect the pH of saliva and result in increased release of nickel ions in saliva of patients with fixed orthodontic appliances in the oral cavity.
Bhusari, Chitra P; Sharma, Divya S
This study observed the topographical pattern of hydroxyapatite deposition and growth (D&G) on bleached enamel following application of two antioxidants (sodium ascorbate and catalase) using atomic force microscope. Twenty enamel specimens (4×3×2mm), prepared from extracted impacted third molars, were mounted in self-cure acrylic and randomly grouped as: Group I-untreated; Group II- 35%H 2 O 2 ; Group III- 35%H 2 O 2 + artificial saliva; Group IV- 35%H 2 O 2 + catalase+ artificial saliva; Group V- 35%H 2 O 2 + sodium ascorbate+ artificial saliva. Groups I and II were observed immediately after treatment. Groups III-V were observed after 72 hrs. Roughness average was also calculated and analyzed with non-parametric Kruskall-Wallis ANOVA and Mann-Whitney tests. H 2 O 2 dissolved matrix, exposed hydroxyapatite crystals (HACs), causing dissolution on the sides of and within HACs and opening up of nano-spaces. Artificial saliva showed growth of dissoluted crystals. Antioxidants+saliva showed potentiated remineralization by D&G on dissoluted HACs of bleached enamel. Catalase potentiated blockshaped, while sodium ascorbate the needle-shaped crystals with stair-pattern of crystallization. Evidence of oxygen bubbles was a new finding with catalase. Maximum roughness average was in group V followed by group II > group IV > group III > group I. Post-bleaching application of catalase and sodium ascorbate potentiated remineralization by saliva, but in different patterns. None of the tested antioxidant could return the original topography of enamel.
Study of experiment on leaching of bisphenol A from infant books to artificial saliva.
Sajiki, Junko; Yanagibori, Ryoko; Kobayashi, Yaeko
2010-05-01
To assess the risk of bisphenol A (BPA) exposure when infants suck or chew infant books, the concentration of BPA leaching from infant books published by Japanese makers to artificial saliva was measured. The concentration of BPA leaching from 10 infant books to 15 ml artificial saliva or water was measured at 37 degrees C for 20 hrs. BPA concentration was measured by high-performance liquid chromatography-electrochemical detection (HPLC-ECD) with solid-phase extraction. BPA was leached from all books when pieces of them were dipped both into saliva and water for 20 hrs. The highest concentration of BPA leaching from one out of 10 books was 43.4 ng/ml (for 2 hrs) in saliva, which was estimated to be approximately 0.052 mg/kg body weight/day for infants aged 6-10 months. As BPA has endocrine-disrupting effects and poses higher risks in infants than in adults, it is desired to reduce BPA use in the printing of infant books from the viewpoint of child health.
Rehman, Abdur; Amin, Faiza; Abbas, Muhammad
2014-11-01
To examine the effect of distilled water, artificial saliva and ethanol on the tensile strength of direct tooth-coloured restorative material. The study was conducted at Dr. Ishrat ul Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences (DUHS), Karachi, from April 2011 to September 2012. The testing was performed at the Pakistan Council of Scientific and Industrial Research (PCSIR) laboratories. Two composite resins Filtek Z250 and Spectrum TPH were tested. Specimens (13 mm x 3 mm x 2 mm) of each material were prepared in the stainless steel mould according to the manufacturers' instructions and distributed into 3 equal groups: one immersed in distilled water, the other in artificial saliva, and the last one in ethanol for 24 hours. Tensile strength was determined after 24 hours in universal Instron Testing Machine. There were 72 specimens in all; 36 (50%) each for Filtek Z250 and Spectrum TPH. The three sub-groups in each case had 12 (33.3%) specimens. For the Filtek Z250, there was no statistically significant difference between immersion in distilled water and artificial saliva, but the ethanol group presented lower tensile strength (p<0.05). For the Spectrum TPH, samples immersed in ethanol and artificial saliva presented lower tensile strength compared to distilled water (p<0.05). The tested composite resins were affected by the immersion media and adversely affected the mechanical properties of composite resins.
Girme, Tejashree Suresh; Agrawal, Jiwanasha Manish; Agrawal, Manish Suresh; Fulari, Sangamesh Gurunath; Shetti, Shraddha Subhash; Kagi, Vishwal Ajith
2017-01-01
Introduction Hand held mobile phones are presently the most popular means of communication worldwide and have transformed our lives in many aspects. The widespread use of such devices have resulted in growing concerns regarding harmful effects of radiations emitted by them. This study was designed to evaluate the effects of mobile phone usage on nickel ion release as well as pH of saliva in patients with fixed orthodontic appliances. Aim To assess the level of nickel ions in saliva and pH of saliva in mobile phone users undergoing fixed orthodontic treatment using inductively coupled plasma atomic emission spectrometry. Materials and Methods A total of 42 healthy patients with fixed orthodontic appliance in mouth for a duration of six to nine months were selected for the study. They were divided into experimental group (n=21) consisting of mobile phone users and control group (n=21) of non mobile phone users. Saliva samples were collected from both the groups and nickel ion levels were measured using inductively coupled plasma-mass spectroscopy. The pH values were also assessed for both groups using pH meter. Unpaired t-test was used for the data analysis. Results Statistical analysis revealed that though the pH levels were reduced and the nickel ion levels were higher in the experimental group compared to the control group, the results were non significant. Conclusion Mobile phone usage may affect the pH of saliva and result in increased release of nickel ions in saliva of patients with fixed orthodontic appliances in the oral cavity. PMID:29207841
Amperometric micro pH measurements in oxygenated saliva.
Chaisiwamongkhol, Korbua; Batchelor-McAuley, Christopher; Compton, Richard G
2017-07-24
An amperometric micro pH sensor has been developed based on the chemical oxidation of carbon fibre surfaces (diameter of 9 μm and length of ca. 1 mm) to enhance the population of surface quinone groups for the measurement of salivary pH. The pH analysis utilises the electrochemically reversible two-electron, two-proton behaviour of surface quinone groups on the micro-wire electrodes. A Nernstian response is observed across the pH range 2-8 which is the pH range of many biological fluids. We highlight the measurement of pH in small volumes of biological fluids without the need for oxygen removal and specifically the micro pH electrode is examined by measuring the pH of commercial synthetic saliva and authentic human saliva samples. The results correspond well with those obtained by using commercial glass pH electrodes on large volume samples.
Ţălu, Ştefan; Bramowicz, Miroslaw; Kulesza, Slawomir; Lainović, Tijana; Vilotić, Marko; Blažić, Larisa
2016-11-01
The aim of this study was to analyse the influence of the artificial saliva on a three-dimensional (3-D) surface texture of contemporary dental composites. The representatives of four composites types were tested: nanofilled (Filtek Ultimate Body, FUB), nanohybrid (Filtek Z550, FZ550), microfilled (Gradia Direct, GD) and microhybrid (Filtek Z250, FZ250). The specimens were polymerised and polished by the multistep protocol (SuperSnap, Shofu). Their surface was examined, before and after 3 weeks' exposure to artificial saliva storage. The surface texture was analysed using the atomic force microscope (AFM). The obtained images were processed to calculate the areal autocorrelation function (AACF), anisotropy ratio S tr (texture aspect ratio), and structure function (SF). The log-log plots of SF were used to calculate fractal properties, such as fractal dimension D, and pseudo-topothesy K. The analysis showed changes in surface anisotropy ratio S tr values, which became higher, whereas the S q roughness (root-mean-square) reduced after the artificial saliva storage. All the samples exhibited bifractal structure before the saliva treatment, but only half of them remained bifractal afterwards (GD, FZ250), whereas the other half turned into a monofractal (FUB, FZ550). The cube-count fractal dimension D cc was found to be material- and treatment-insensitive. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.
Dynamic changes in saliva after acute mental stress
Naumova, Ella A.; Sandulescu, Tudor; Bochnig, Clemens; Khatib, Philipp Al; Lee, Wing-Kee; Zimmer, Stefan; Arnold, Wolfgang H.
2014-01-01
Stress-related variations of fluoride concentration in supernatant saliva and salivary sediment, salivary cortisol, total protein and pH after acute mental stress were assessed. The hypothesis was that stress reactions have no influence on these parameters. Thirty-four male students were distributed into two groups: first received the stress exposure followed by the same protocol two weeks later but without stress exposure, second underwent the protocol without stress exposure followed by the stress exposure two weeks later. The stressor was a public speech followed by tooth brushing. Saliva was collected before, immediately after stress induction and immediately, at 10, 30 and 120 min. after tooth brushing. Cortisol concentrations, total protein, intraoral pH, and fluoride content in saliva were measured. The data were analyzed statistically. Salivary sediment was ca 4.33% by weight of whole unstimulated saliva. Fluoride bioavailability was higher in salivary sediment than in supernatant saliva. The weight and fluoride concentration was not altered during 2 hours after stress exposure. After a public speech, the salivary cortisol concentration significantly increased after 20 minutes compared to the baseline. The salivary protein concentration and pH also increased. Public speaking influences protein concentration and salivary pH but does not alter the fluoride concentration of saliva. PMID:24811301
López-Alías, José F; Martinez-Gomis, Jordi; Anglada, Josep M; Peraire, Maria
2006-09-01
The aims of this study were to quantify the metallic ions released by various dental alloys subjected to a continuous flow of saliva and to estimate the nutritional and toxicological implications of such a release. Four pieces of three nickel-based, one noble, one high-noble and two copper-aluminum alloys were cast and then immersed in a continuous flow of artificial saliva for 15 days. To simulate three meals a day, casts were subjected to thrice-daily episodes, lasting 30 min each and consisting of pH decreases and salinity increases. After 15 days, the metallic ions in the artificial saliva were analyzed. Data were expressed as averaged release rate: microg/cm2/day of ion released for each alloy. The highest value of 95% Cl of each ion was adapted to a hypothetical worst scenario of a subject with 100 cm2 of exposed metal surface. The results were compared with the tolerable upper daily intake level of each ion. The copper-aluminum alloys released copper, aluminum, nickel, manganese and iron. The nickel-based alloys essentially released nickel and chromium, while the beryllium-containing alloy released beryllium and significantly more nickel. The noble and high-noble alloys were very resistant to corrosion. The amount of ions released remained far below the upper tolerable intake level, with the exception of nickel, released by beryllium-containing nickel-based alloy, whose levels approach 50% of this threshold. The daily amount of ions released seems to be far below the tolerable upper intake levels for each ion.
Kelly, M; Vardhanabhuti, B; Luck, P; Drake, M A; Osborne, J; Foegeding, E A
2010-05-01
Whey protein beverages are adjusted to pH <4.5 to enhance clarity and stability, but this pH level is also associated with increased astringency. The goal of this investigation was to determine the effects of protein concentration on astringency and interactions between whey and salivary proteins. Whey protein beverages containing 0.25 to 13% (wt/wt) beta-lactoglobulin and 0.017% (wt/wt) sucralose at pH 2.6 to 4.2 were examined using descriptive sensory analysis. Controls were similar pH phosphate buffers at phosphate concentrations equivalent to the amount of phosphoric acid required to adjust the pH of the protein solution. Changes in astringency with protein concentration depended on pH. At pH 3.5, astringency significantly increased with protein concentration from 0.25 to 4% (wt/wt) and then remained constant from 4 to 13% (wt/wt). Conversely, at pH 2.6, astringency decreased with an increase in protein concentration [0.5-10% (wt/wt)]. This suggests a complex relationship that includes pH and buffering capacity of the beverages. Furthermore, saliva flow rates increased with increasing protein concentrations, showing that the physiological conditions in the mouth change with protein concentration. Maximum turbidity of whey protein-saliva mixtures was observed between pH 4.6 and 5.2. Both sensory evaluation and in vitro study of interactions between beta-LG and saliva indicate that astringency of whey proteins is a complex process determined by the extent of aggregation occurring in the mouth, which depends on the whey protein beverage pH and buffering capacity in addition to saliva flow rate. Copyright 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Moreira, A R; Passos, I A; Sampaio, F C; Soares, M S M; Oliveira, R J
2009-08-01
Alterations in salivary parameters may increase the caries risk in diabetic children, but, contradictory data on this issue have been reported. The aims of this study were to compare salivary parameters (flow rate, pH and calcium concentration) between healthy and type 1 diabetes mellitus (T1DM) individuals. The sample consisted of 7- to 18-year-old individuals divided into two groups: 30 subjects with T1DM (group A) and 30 healthy control subjects (group B). Fasting glucose levels were determined. Unstimulated and stimulated saliva was collected. The pH of unstimulated saliva was measured with paper strips and an electrode. Calcium concentrations in stimulated saliva were determined with a selective electrode. Group A individuals had inadequate blood glucose control (HbA(1C) >9%), with means +/- SD unstimulated salivary flow rate of 0.15 +/- 0.1 mL/min compared to 0.36 +/- 0.2 mL/min for group B (P < 0.01). Stimulated salivary flow rate was similar by both groups and above 2.0 mL/min. Saliva pH was 6.0 +/- 0.8 for group A and significantly different from 7.0 +/- 0.6 for group B (P < 0.01). Salivary calcium was 14.7 +/- 8.1 mg/L for group A and significantly higher than 9.9 +/- 6.4 mg/L for group B (P < 0.01). Except for elevated calcium concentrations in saliva, salivary parameters favoring caries such as low saliva pH and unstimulated salivary flow rate were observed in T1DM individuals.
TOLENTINO, Elen de Souza; CHINELLATO, Luiz Eduardo Montenegro; TARZIA, Olinda
2011-01-01
Objectives The aim of this work was to evaluate saliva and tongue coating pH in oral healthy patients with morning bad breath before and after use of different oral mouthrinses. Material and Methods aliva and tongue coating pH of 50 patients allocated in 5 groups were measured respectively by a digital pHmeter and color pH indicators, before, immediately after and 30 min after rinsing 5 different mouthrinses: cetilpiridine chloride associated with sodium chloride, triclosan, enzymatic solution, essential oil and distilled water. Results Only triclosan and essential oil increased salivary pH immediately after rising. The enzymatic solution decreased salivary and tongue coating pH immediately after rinsing. Conclusion Salivary pH tended to be acidic while tongue coating pH tended to be alkaline, even after rising. Triclosan and essential oil mouthrinses increased salivary pH immediately after rinsing. Enzymatic solution decreased saliva and tongue coating pH immediately after rising. PMID:21552707
Austin, R S; Rodriguez, J M; Dunne, S; Moazzez, R; Bartlett, D W
2010-10-01
To investigate the effect of an aqueous sodium fluoride solution of increasing concentration on erosion and attrition of enamel and dentine in vitro. Enamel and dentine sections from caries-free human third molars were polished flat and taped (exposing a 3 mm x 3 mm area) before being randomly allocated to 1 of 5 groups per substrate (n=10/gp): G1 (distilled water control); G2 (225 ppm NaF); G3 (1450 ppm NaF); G4 (5000 ppm NaF); G5 (19,000 ppm NaF). All specimens were subjected to 5, 10 and 15 cycles of experimental wear [1 cycle=artificial saliva (2h, pH 7.0)+erosion (0.3% citric acid, pH 3.2, 5 min)+fluoride/control (5 min)+attrition (60 linear strokes in artificial saliva from enamel antagonists loaded to 300 g)]. Following tape removal, step height (SH) in mum was measured using optical profilometry. When the number of cycles increased the amount of tooth surface loss increased significantly in enamel and dentine after attrition and erosion and for dentine after attrition. Attrition and erosion resulted in greater surface loss than attrition alone after 15 cycles of experimental wear of enamel. 5000 ppm and 19,000 ppm sodium fluoride solutions had a protective effect on erosive and attritional enamel tooth wear in vitro, however no other groups showed significant differences. The more intensive the fluoride regime the more protection was afforded to enamel from attrition and erosion. However, in this study no such protective effect was demonstrated for dentine. Copyright 2010 Elsevier Ltd. All rights reserved.
Corrosion Behavior of Titanium in Artificial Saliva by Lactic Acid
Qu, Qing; Wang, Lei; Chen, Yajun; Li, Lei; He, Yue; Ding, Zhongtao
2014-01-01
As one of the main products produced by oral microorganisms, the role of lactic acid in the corrosion of titanium is very important. In this study, the corrosion behavior of titanium in artificial saliva with and without lactic acid were investigated by open-circuit potentials (OCPs), polarization curves and electrochemical impedance spectroscopy (EIS). OCP firstly increased with the amount of lactic acid from 0 to 3.2 g/L and then tended to decrease from 3.2 to 5.0 g/L. The corrosion of titanium was distinctly affected by lactic acid, and the corrosion rate increased with increasing the amount of lactic acid. At each concentration of lactic acid, the corrosion rate clearly increased with increasing the immersing time. Results of scanning electron microscopy (SEM) also indicated that lactic acid accelerated the pitting corrosion in artificial saliva. A probable mechanism was also proposed to explain the experimental results. PMID:28788143
Williams, J A; Billington, R W; Pearson, G J
2001-01-01
The objective of this study was to determine long term release of fluoride from a resin-modified glass-ionomer cement (RMGIC) (Fuji II LC (FLC)) compared with that from two conventional acid-base setting cements (HiDense (HD) and KetacSilver (KS)) marketed for similar restorative purposes. Fluoride release from discs of cement immersed in water or artificial saliva was measured for 2.7 years using an ion selective electrode technique. The RMGIC was affected by water if immersed immediately after setting. This is similar to conventional acid-base cements and the experimental method was designed to allow for this. Over the 2.7-year period, the RMGIC and HD released similar amounts of fluoride into both water and artificial saliva. In water, the RMGIC released the most fluoride, while in artificial saliva the highest release was from HD. KS released the least amount of fluoride in both immersing liquids. In artificial saliva, release was reduced to 17-25% of that found in water, with the RMGIC showing the greatest reduction. Both acid-base cured cements showed changes in colour over the 2.7-year span, while the colour of the RMGIC was stable. It was concluded that the RMGIC released equivalent or greater amounts of fluoride than the two acid-base cure glass-ionomers over a period of 2.7 years.
NASA Astrophysics Data System (ADS)
Mahmoud, Ghada A.; Ali, Amr El-Hag; Raafat, Amany I.; Badawy, Nagwa A.; Elshahawy, Mai. F.
2018-06-01
A series of mucoadhesive nanocomposites with self disinfection properties composed of acrylic acid, polyethylene glycol and ZnO nanoparticles (AAc/PEG)-ZnO were developed for localized buccal Propranolol HCl delivery. γ-irradiation as a clean tool for graft copolymerization process was used for the preparation of (AAc/PEG) hydrogels. In suite precipitation technique was used for ZnO nanoparticles immobilization within (AAc/PEG) hydrogels. The developed (AAc/PEG)-ZnO nanocomposites were characterized by X-ray diffraction (XRD), UV-Vis spectrophotometer, energy dispersive X-ray spectroscopy (EDX) and scanning electron microscopy (SEM) to confirm the success of ZnO nanoparticles formation within the (AAc/PEG) matrices. The presence of ZnO nanoparticles improves the thermal stability as indicated using thermogravimetric analysis (TGA). The mucoadhesion characteristics such as hydration degree, surface pH, and mucoadhesive strength were evaluated in artificial saliva solution. The self disinfection property of the developed (AAc/PEG)-ZnO nanocomposites was investigated by examining their resistance to pathogenic microorganisms such as Staphylococcus aureus, Bacillus subtilis, and Escherichia coli using disc diffusion method. The release of Propranolol -HCl drug in artificial saliva was found to obey a non-Fickian diffusion mechanism. The obtained results suggests that (AAc/PEG)-ZnO nanocomposites could be used as mucoadhesive carrier for buccal drug delivery with efficient antibacterial properties.
Khan, Aftab Ahmed; Siddiqui, Adel Zia; Al-Kheraif, Abdulaziz A; Zahid, Ambreen; Divakar, Darshan Devang
2015-01-01
Objective: Erosion of tooth surface is attributed to recent shift in diet pattern and frequent use of beverages. The aim of this research was to evaluate the effects of different beverages on surface topography and hardness of nano-filled composite material. Methods: Sixty flat disc shaped resin composite samples were fabricated and placed in distilled water for 24 hours. After 24 hours test samples were dried and divided into 4 groups. Group A (n=15) specimens were placed in tight amber bottle comprising 25 ml of artificial saliva. Similarly Group B, C and D were stored in equal amounts of orange juice, milk and coca cola drink respectively. Samples were checked for hardness and surface changes were evaluated with scanning electron microscopy. Results: There were strong significant difference observed in samples immersed in orange juice and artificial saliva. A strong significant difference was seen between Group D and Group A. Group A and Group C showed no significant difference. The micro-hardness test showed reduced values among all samples. Conclusion: Beverages consumed daily have a negative influence on hardness and surface degradation of nano-filled dental composite. Comparatively, nano-filled composites possess higher surface area to volume ratio of their fillers particle size may lead to higher surface roughness than other resin based dental biomaterials. PMID:26430417
Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants.
Alves, Celha Borges Costa; Segurado, Márcio Nunes; Dorta, Miriam Cristina Leandro; Dias, Fátima Ribeiro; Lenza, Maurício Guilherme; Lenza, Marcos Augusto
2016-01-01
To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic.
Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants
Alves, Celha Borges Costa; Segurado, Márcio Nunes; Dorta, Miriam Cristina Leandro; Dias, Fátima Ribeiro; Lenza, Maurício Guilherme; Lenza, Marcos Augusto
2016-01-01
ABSTRACT Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. Results: No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Conclusion: Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic. PMID:27901227
Efficacy of pastes containing CPP-ACP and CPP-ACFP in patients with Sjögren's syndrome.
Peric, Tamara; Markovic, Dejan; Petrovic, Bojan; Radojevic, Vesna; Todorovic, Tatjana; Radicevic, Biljana Andjelski; Heinemann, Radmila Jancic; Susic, Gordana; Popadic, Aleksandra Peric; Spiric, Vesna Tomic
2015-12-01
The purpose of this study was to evaluate efficacy of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and casein phosphopeptide-amorphous calcium fluoride phosphate (CPP-ACFP) containing pastes among individuals with Sjögren's syndrome (SS). Thirty patients were randomised into three groups: CPP-ACP, CPP-ACFP, and 0.05 % NaF to be used two times a day during a 28-day experimental period. Saliva was analysed for flow rate, pH, buffering capacity and mineral concentrations. Dental plaque was examined for pH. Following the formation of artificial carious lesion, participants wore enamel slabs for an in situ remineralisation study. Remineralisation potential was examined using scanning electron microscope (SEM) and energy dispersive spectroscopic (EDS) technique. SE microphotographs were subsequently analysed for area, diameter, perimeter, roundness and the number of enamel defects and percentage of tooth surface affected by defects. At the end of the experimental period, a slight increase of salivary pH could have been observed. No differences in mineral composition of saliva were noted. The use of CPP-ACP and CPP-ACFP contributed to a significant rise of plaque pH. Image analysis revealed excessive reduction of defects' dimensions in the three experimental groups, and a decrease of the number of enamel defects in the CPP-ACP and CPP-ACFP groups. The EDS analysis did not show differences in Ca/P, Ca/O and P/O ratios in any of the treatment groups. CPP-ACP and CPP-ACFP hold promise as remineralising agents for patients with SS. Pastes containing CPP-ACP/CPP-ACFP show enhanced remineralisation potential compared with NaF mouthrinse in patients with SS.
Effect of two mouthwashes on salivary ph.
Belardinelli, Paola A; Morelatto, Rosana A; Benavidez, Tomás E; Baruzzi, Ana M; López de Blanc, Silvia A
2014-01-01
To analyze the effect of two mouthwashes on salivary pH and correlate it with age, buffer capacity and saliva flow rate in healthy volunteers, a crossover phase IV clinical study involving three age-based groups was designed. Two commercial mouthwashes (MW), Cool Mint ListerineR (MWa) and Periobacter R (MWb) were used. The unstimulated saliva of each individual was first characterized by measuring flow rate, pH, and buffer capacity. Salivary pH was evaluated before rinsing with a given MW, immediately after rinsing, 5 minutes later, and then every 10 min (at 15, 25, 35 min) until the baseline pH was recovered. Paired t-test, ANOVA with a randomized block design, and Pearson correlation tests were used. Averages were 0.63 mL/min, 7.06, and 0.87 for flow rate, pH, and buffer capacity, respectively. An immediate significant increase in salivary pH was observed after rinsing, reaching average values of 7.24 (MWb) and 7.30 (MWa), which declined to an almost stable value 15 minutes. The great increase in salivary pH, after MW use shows that saliva is a dynamic system, and that the organism is capable of responding to a stimulus with changes in its composition. It is thus evident that pH of the external agent alone is not a good indicator for its erosive potential because biological systems tend to neutralize it. The results of this study enhance the importance of in vivo measurements and reinforce the concept of the protective action of saliva.
The Release of Elements from Dental Casting Alloy into Cell-Culture Medium and Artificial Saliva
Can, Gülşen; Akpınar, Gül; Aydın, Ahmet
2007-01-01
Objectives The biocompatibility of dental casting alloys is a critical issue because these alloys are in long-term intimate contact with oral tissues. Since the biocompatibility of alloys is not completely known; the release of elements from the alloys has been studied. The aim of this study was to compare the elemental release from dental casting alloy during exposure to artificial saliva and cell-culture medium. Materials and Methods Twenty specimens made from Ni-Cr alloy were provided in the form of 5 mm diameter discs, 2 mm in thickness with a 7 mm stem attached to one face to facilitate handling. Ten of twenty samples were polished separately using a conventional technique. The remaining ten samples were left sandblasted with 50 μm Al203. Ten samples (5 polished, 5 sandblasted) were separately placed into cell-culture wells with Dulbecco’s Modified Eagle’s Medium. The other ten samples were placed separately into cell-culture wells with artificial saliva. The samples were subjected in contact with these medium for 30 days. These medium were collected every 7 days. The cell-culture medium and artificial saliva without alloy samples were subjected to elemental analyses as a control. At the end of the exposure time, Atomic Absorption Spectrometry (AAS) was used to determine the release of elements from the alloys into all collected medium. Statistical analyses were assessed with two-way ANOVA. Results In general, the elemental release occurred with in all medium. The elemental releases of sandblasted alloys were higher than polished alloys. Artificial saliva was found to cause more release from the samples. In both media, Ni released from polished and sandblasted alloys were higher than Cr and Mo. Conlusions The results suggest that the release of elements from the alloys might have correlated with the environments and the surface of dental alloy. PMID:19212482
Maden, Eda Arat; Acar, Özge; Altun, Ceyhan; Polat, Günseli Güven
This study aimed to investigate the effect of acidulated phosphate fluoride (APF) gel and casein phosphopeptide/amorphous calciumphosphate (CPP-ACP) on the dental erosion produced by carbonated soft drink in primary teeth. This study evaluated by an in vitro model the effect of APF gel and CPP-ACP on the dental enamel previously subjected to erosive challenge with carbonated soft drink. Sixty sound human primary molars were prepared by embedding the crown sections in acrylic resin blocks leaving the enamel surfaces exposed. The surface roughness of the enamel was measured with prophilometry at baseline. Specimens were randomly divided into three treatment groups (n:20): artificial saliva, CPP-ACP, 1.23% APF gel. All specimens were then exposed to an erosive challenge of carbonated soft drink and artificial saliva for 20 cycles of 20 seconds each. Demineralization-remineralization cycles was repeated twice at eight-hour intervals and roughness values were measured. Enamel samples were treated with artificial saliva, CPP-ACP, 1.23% APF gel applied for 10 min after erosive challenge. The arithmetic average roughness (Ra) readings were recorded after remineralization agents were applied. The mean surface roughness in all groups increased significantly after erosion process and decreased after remineralization treatment. After treatment, the mean surface roughness of the 1.23% APF gel group was significantly less than the other groups and the mean surface roughness of the artificial saliva group was significantly more than the other groups. 1.23% APF gel showed the highest protective effect against erosive enamel loss. Under the conditions of this study, artificial saliva, CPP-ACP and 1.23% APF treatments were able to reduce erosive enamel loss produced by carbonated soft drink in primary teeth. However, 1.23% APF gel showed the highest protective effect against erosive enamel loss.
The release of elements from dental casting alloy into cell-culture medium and artificial saliva.
Can, Gülşen; Akpınar, Gül; Aydın, Ahmet
2007-04-01
The biocompatibility of dental casting alloys is a critical issue because these alloys are in long-term intimate contact with oral tissues. Since the biocompatibility of alloys is not completely known; the release of elements from the alloys has been studied. The aim of this study was to compare the elemental release from dental casting alloy during exposure to artificial saliva and cell-culture medium. Twenty specimens made from Ni-Cr alloy were provided in the form of 5 mm diameter discs, 2 mm in thickness with a 7 mm stem attached to one face to facilitate handling. Ten of twenty samples were polished separately using a conventional technique. The remaining ten samples were left sandblasted with 50 mum Al(2)0(3). Ten samples (5 polished, 5 sandblasted) were separately placed into cell-culture wells with Dulbecco's Modified Eagle's Medium. The other ten samples were placed separately into cell-culture wells with artificial saliva. The samples were subjected in contact with these medium for 30 days. These medium were collected every 7 days. The cell-culture medium and artificial saliva without alloy samples were subjected to elemental analyses as a control. At the end of the exposure time, Atomic Absorption Spectrometry (AAS) was used to determine the release of elements from the alloys into all collected medium. Statistical analyses were assessed with two-way ANOVA. In general, the elemental release occurred with in all medium. The elemental releases of sandblasted alloys were higher than polished alloys. Artificial saliva was found to cause more release from the samples. In both media, Ni released from polished and sandblasted alloys were higher than Cr and Mo. The results suggest that the release of elements from the alloys might have correlated with the environments and the surface of dental alloy.
Effect of storage in artificial saliva and thermal cycling on Knoop hardness of resin denture teeth.
Assunção, Wirley Gonçalves; Gomes, Erica Alves; Barão, Valentim Adelino Ricardo; Barbosa, Débora Barros; Delben, Juliana Aparecida; Tabata, Lucas Fernando
2010-07-01
This study aimed to evaluate the effect of different storage periods in artificial saliva and thermal cycling on Knoop hardness of 8 commercial brands of resin denture teeth. Eigth different brands of resin denture teeth were evaluated (Artplus group, Biolux group, Biotone IPN group, Myerson group, SR Orthosit group, Trilux group, Trubyte Biotone group, and Vipi Dent Plus group). Twenty-four teeth of each brand had their occlusal surfaces ground flat and were embedded in autopolymerized acrylic resin. After polishing, the teeth were submitted to different conditions: (1) immersion in distilled water at 37+/-2 degrees C for 48+/-2h (control); (2) storage in artificial saliva at 37+/-2 degrees C for 15, 30 and 60 days, and (3) thermal cycling between 5 and 55 degrees C with 30-s dwell times for 5000 cycles. Knoop hardness test was performed after each condition. Data were analyzed with two-way ANOVA and Tukey's test (alpha=.05). In general, SR Orthosit group presented the highest statistically significant Knoop hardness value while Myerson group exhibited the smallest statistically significant mean (P<.05) in the control period, after thermal cycling, and after all storage periods. The Knoop hardness means obtained before thermal cycling procedure (20.34+/-4.45 KHN) were statistically higher than those reached after thermal cycling (19.77+/-4.13 KHN). All brands of resin denture teeth were significantly softened after storage period in artificial saliva. Storage in saliva and thermal cycling significantly reduced the Knoop hardness of the resin denture teeth. SR Orthosit denture teeth showed the highest Knoop hardness values regardless the condition tested. Copyright 2010 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Application of the thin electrolyte layer technique to corrosion testing of dental materials
NASA Astrophysics Data System (ADS)
Ledvina, Martin
Proper simulation of the oral environment for the corrosion testing of dental materials is crucial for determining corrosion rates and mechanisms correctly. In this study, the thin electrolyte layer technique (TET) was characterized and employed to investigate the importance of the chemical composition of the testing environment on the outcome of electrochemical tests. The thickness of the electrolyte layer in TET is only 0.5 mm and contains only 20 muL of electrolyte. This arrangement simulates the physical characteristics of the oral environment and facilitates testing in human saliva. Oxygen availability for reduction on the sample surface was determined, using cathodic polarization of Pt in borate buffer, to be lower in TET than in traditional (bulk electrolyte) techniques. Appreciable differences were found during polarization experiments on 316 L SS in saline and artificial saliva. Oxygen content was found to play a significant role in the corrosivity of various species contained in artificial saliva. Potentiodynamic polarization employing human saliva in TET on 316L SS proved to be very different from tests performed in artificial saliva. This was believed to be due to the presence of organic species, specifically proteins, contained in human saliva. This was further confirmed by cyclic polarization and corrosion current measurements of four commercial nickel-chromium (NiCr) alloys with varying amounts of Be. For this phase of the experiment, artificial saliva (AS), AS with 1% albumin, AS with 1% of mucin and parotid human saliva were employed as electrolytes. The results obtained in the various electrolytes depended on the composition, microstructure, stability of passive film, and the presence of casting porosity of the alloys tested. Proteins had insignificant effect on alloys with highly stable passive films, whereas, corrosion rates increased substantially in those alloys with compromised passive film formation. Proteins, especially mucin, lowered the activity of pores and seemed to produce an inhibitive action against localized corrosion. The same trends were observed in human saliva. To clarify the mechanisms of protein-surface interaction, electrochemical impedance spectroscopy (EIS) was employed with the same alloy-electrolyte combinations. Based on the results, it was hypothesized that proteins are adsorbed to the anodic areas where pits may be forming or casting porosity exists. The electrostatic interaction and affinity of proteins for metallic ions plays a significant role. The absorbed macromolecules physically block transport of reactants to and from the interface and slow down the corrosion reaction appreciably. Overall, this investigation contributed to the further understanding of the electrochemistry of the oral environment, particularly the contribution of proteinaceous species.
Effect of Fixed Orthodontic Treatment on Salivary Flow, pH and Microbial Count.
Arab, Sepideh; Nouhzadeh Malekshah, Sepideh; Abouei Mehrizi, Ehsan; Ebrahimi Khanghah, Anita; Naseh, Roya; Imani, Mohammad Moslem
2016-01-01
The present study was designed to evaluate the changes in saliva properties and oral microbial flora in patients undergoing fixed orthodontic treatment. Two important saliva properties namely the salivary flow rate and pH as well as oral microbial flora were assessed in 30 orthodontic patients before starting fixed orthodontic treatment and after six, 12 and 18 weeks of treatment. Selective media, Sabouraud dextrose agar, Mitis salivarius agar and Rogosa agar were used for isolation of Candida albicans, Streptococcus mutans and Lactobacillus acidophilus, respectively. Statistical analysis was performed using Friedman and Dunn's tests. P< 0.05 was considered statistically significant. After six, 12 and 18 weeks of commencing fixed orthodontic treatment, the total colony counts of Candida albicans, Streptococcus mutans and Lactobacillus acidophilus showed a significant increase. The saliva pH decreased during the orthodontic treatment (P< 0.05) while the salivary flow did not change significantly. Fixed orthodontic treatment causes major changes in the saliva properties. The changes in oral microflora and saliva properties show the importance of caries preventive measures during orthodontic treatment.
Hosseini-Yekani, Amene; Nadjarzadeh, Azadeh; Vossoughi, Mehrdad; Reza, Javad Zavvar; Golkari, Ali
2018-01-01
Objectives: There are inconsistent data about the association between saliva properties, dental caries, and periodontal status. In this study, we tried to examine the association between dental caries and periodontal status with salivary viscosity, flow rate, pH, and buffering capacity in adults. Methods: In the present cross-sectional study, 450 female teachers were randomly selected from schools located in Yazd, Iran. Oral examinations were conducted, and unstimulated saliva samples were collected. Salivary viscosity, flow rate, pH, and buffering capacity were assessed. The salivary physicochemical properties were compared among teachers with different types of oral health. Analyses were done using the Statistical Package for the Social Sciences version 16. Results: In total, 431 female teachers aged 40.45 ± 8.18 years were included in the study. Salivary flow rate, buffering capacity, pH, and viscosity, community periodontal index status were not significantly different in participants with and without tooth caries. There was a reverse linear association between salivary pH and flow rate with the decayed, missed, and filled teeth index (P < 0.05). The saliva buffering capacity was not significantly related to dental properties. Those with bleeding on probing had lower salivary pH, and buffering capacity compared to those with healthy gum. However, the salivary resting flow rate was not different in participants with bleeding on probing and healthy participants. Conclusion: Based on our results, saliva properties might be important predictors in oral health status. This means that any change in saliva combination might affect periodontal and dental diseases. Future prospective studies are recommended to confirm these results. PMID:29629329
Muñoz-González, Carolina; Feron, Gilles; Guichard, Elisabeth; Rodríguez-Bencomo, J José; Martín-Álvarez, Pedro J; Moreno-Arribas, M Victoria; Pozo-Bayón, M Ángeles
2014-08-20
The aim of this work was to determine the role of saliva in wine aroma release by using static and dynamic headspace conditions. In the latter conditions, two different sampling points (t = 0 and t = 10 min) corresponding with oral (25.5 °C) and postoral phases (36 °C) were monitored. Both methodologies were applied to reconstituted dearomatized white and red wines with different nonvolatile wine matrix compositions and a synthetic wine (without matrix effect). All of the wines had the same ethanol concentration and were spiked with a mixture of 45 aroma compounds covering a wide range of physicochemical characteristics at typical wine concentrations. Two types of saliva (human and artificial) or control samples (water) were added to the wines. The adequacy of the two headspace methodologies for the purposes of the study (repeatability, linear ranges, determination coefficients, etc.) was previously determined. After application of different chemometric analysis (ANOVA, LSD, PCA), results showed a significant effect of saliva on aroma release dependent on saliva type (differences between artificial and human) and on wine matrix using static headspace conditions. Red wines were more affected than white and synthetic wines by saliva, specifically human saliva, which provoked a reduction in aroma release for most of the assayed aroma compounds independent of their chemical structure. The application of dynamic headspace conditions using a saliva bioreactor at the two different sampling points (t = 0 and t = 10 min) showed a lesser but significant effect of saliva than matrix composition and a high influence of temperature (oral and postoral phases) on aroma release.
Wang, L; Wu, W; Wang, G
2018-02-27
Objective: To investigate the significance of the detection of pepsin in saliva and the pharyngeal pH monitoring in the diagnosis of laryngopharyngeal reflux disease(LPRD). Methods: A total of 176 patients (140 patients with simple pharyngitis and 36 patients with space-occupying lesions of larynx) who were suspected to have laryngopharyngeal reflux between February and December 2016 were retrospectively reviewed. All the patients were evaluated with reflux symptom index (RSI), reflux finding score (RFS) and 24-hour pharyngeal pH monitoring(Dx-pH). Saliva of patients was collected and the pepsin in the saliva was measured by enzyme-linked immunosorbent assay (ELISA). Results: The positive rate of RSI (RSI>13) and/or RFS (RFS>7) was 56.8% (100/176). The positive rate of pepsin in saliva was 40.9% (72/176) and pepsin in saliva collected at the time of onset of symptom was much higher than that at other time points ( P <0.001). The positive rate of pepsin in saliva, Ryan score and the pH<6.0 laryngopharyngeal reflux in space-occupying lesions group [55.6%(20/36), 27.8% (10/36), 69.4%(25/36), respectively] were all higher than simple pharyngitis group [37.1% (52/140), 5.0% (7/140), 50% (70/140), respectively] ( P =0.045, P <0.001, P =0.037, respectively). Conclusions: The detection of pepsin in saliva and the pharyngeal pH monitoring reflected different reflux agents, and there was great significance for the diagnosis of LPRD by using two methods together. We found that the weak acid state and consequent pepsin damage played an important role in the occurrence and development of space-occupying lesions of larynx.
Corrosion Performance of Fe-Cr-Ni Alloys in Artificial Saliva and Mouthwash Solution
Porcayo-Calderon, J.; Casales-Diaz, M.; Salinas-Bravo, V. M.; Martinez-Gomez, L.
2015-01-01
Several austenitic stainless steels suitable for high temperature applications because of their high corrosion resistance and excellent mechanical properties were investigated as biomaterials for dental use. The steels were evaluated by electrochemical techniques such as potentiodynamic polarization curves, cyclic polarization curves, measurements of open circuit potential, and linear polarization resistance. The performance of steels was evaluated in two types of environments: artificial saliva and mouthwash solution at 37°C for 48 hours. In order to compare the behavior of steels, titanium a material commonly used in dental applications was also tested in the same conditions. Results show that tested steels have characteristics that may make them attractive as biomaterials for dental applications. Contents of Cr, Ni, and other minor alloying elements (Mo, Ti, and Nb) determine the performance of stainless steels. In artificial saliva steels show a corrosion rate of the same order of magnitude as titanium and in mouthwash have greater corrosion resistance than titanium. PMID:26064083
In vitro progression of artificial white spot lesions sealed with an infiltrant resin.
Gelani, R; Zandona, A F; Lippert, F; Kamocka, M M; Eckert, G
2014-01-01
This study assessed the ability of an infiltrant resin (Icon, DMG Chemisch-Pharmazeutische Fabrik GmbH, Hamburg, Germany) to prevent artificial lesion progression in vitro when used to impregnate white spot lesions and also assessed the effect of saliva contamination on resin infiltration. Enamel specimens (n=252) were prepared and covered with nail varnish, leaving a window of sound enamel. After demineralization (pH 5.0; four weeks), specimens were divided into six groups (n=42 per group): group 1, 2% fluoride gel (positive control); group 2, resin infiltrant; group 3, resin infiltrant + fluoride gel; group 4, no treatment (negative control); group 5, resin infiltrant application after saliva contamination; and group 6, resin infiltrant + fluoride gel after saliva contamination. Specimens from each group were cut perpendicular to the surface, and one-half of each specimen was exposed to a demineralizing solution for another four weeks. The other half was set aside as a record of initial lesion depth and was used later in the determination of lesion progression. Lesion progression and infiltrant penetration were measured using confocal laser scanning microscopy (CLSM) and transverse microradiography (TMR). For lesion depth, based on CLSM, groups 2 and 3 showed the least changes when submitted to demineralization challenge, followed by group 1, then groups 5 and 6, and finally group 4. There were no significant differences between groups 2 and 3 or groups 5 and 6 in their ability to inhibit further lesion progression (p<0.05). Based on TMR, groups 2 and 3 also showed the fewest changes when submitted to demineralization challenge, followed by group 5, then groups 1 and 6, and finally group 4. In terms of mineral loss as measured by TMR, all groups that contained fluoride (groups 1, 3, and 6) show less percentage change in mineral loss than the groups that did not contain fluoride (groups 2, 4, and 5). It can be concluded that infiltrant penetration into early enamel lesions inhibited further demineralization in vitro, especially in the presence of fluoride. Saliva contamination decreased the ability of the infiltrant to prevent further demineralization, but the presence of fluoride seemed to counteract this effect.
Li, Fang; Weir, Michael D.; Fouad, Ashraf F.; Xu, Hockin H.K.
2014-01-01
Objectives Antibacterial primer and adhesive are promising to inhibit biofilms and caries. Since restorations in vivo are exposed to saliva, one concern is the attenuation of antibacterial activity due to salivary pellicles. The objective of this study was to investigate the effects of salivary pellicles on bonding agents containing a new monomer dimethylaminododecyl methacrylate (DMADDM) or nanoparticles of silver (NAg) against biofilms for the first time. Methods DMADDM and NAg were synthesized and incorporated into Scotchbond Multi-Purpose adhesive and primer. Specimens were either coated or not coated with salivary pellicles. A microcosm biofilm model was used with mixed saliva from ten donors. Two types of culture medium were used: an artificial saliva medium (McBain), and Brain Heart Infusion (BHI) medium without salivary proteins. Metabolic activity, colony-forming units (CFU), and lactic acid production of plaque microcosm biofilms were measured (n = 6). Results Bonding agents containing DMADDM and NAg greatly inhibited biofilm activities, even with salivary pellicles. When using BHI, the pre-coating of salivary pellicles on resin surfaces significantly decreased the antibacterial effect (p < 0.05). When using artificial saliva medium, pre-coating of salivary pellicles on resin did not decrease the antibacterial effect. These results suggest that artificial saliva yielded medium-derived pellicles on resin surfaces, which provided attenuating effects on biofilms similar to salivary pellicles. Compared with the commercial control, the DMADDM-containing bonding agent reduced biofilm CFU by about two orders of magnitude. Significance Novel DMADDM- and NAg-containing bonding agents substantially reduced biofilm growth even with salivary pellicle coating on surfaces, indicating a promising usage in saliva-rich environment. DMADDM and NAg may be useful in a wide range of primers, adhesives and other restoratives to achieve antibacterial and anti-caries capabilities. PMID:24332270
Li, Fang; Weir, Michael D; Fouad, Ashraf F; Xu, Hockin H K
2014-02-01
Antibacterial primer and adhesive are promising to inhibit biofilms and caries. Since restorations in vivo are exposed to saliva, one concern is the attenuation of antibacterial activity due to salivary pellicles. The objective of this study was to investigate the effects of salivary pellicles on bonding agents containing a new monomer dimethylaminododecyl methacrylate (DMADDM) or nanoparticles of silver (NAg) against biofilms for the first time. DMADDM and NAg were synthesized and incorporated into Scotchbond Multi-Purpose adhesive and primer. Specimens were either coated or not coated with salivary pellicles. A microcosm biofilm model was used with mixed saliva from ten donors. Two types of culture medium were used: an artificial saliva medium (McBain), and Brain Heart Infusion (BHI) medium without salivary proteins. Metabolic activity, colony-forming units (CFU), and lactic acid production of plaque microcosm biofilms were measured (n=6). Bonding agents containing DMADDM and NAg greatly inhibited biofilm activities, even with salivary pellicles. When using BHI, the pre-coating of salivary pellicles on resin surfaces significantly decreased the antibacterial effect (p<0.05). When using artificial saliva medium, pre-coating of salivary pellicles on resin did not decrease the antibacterial effect. These results suggest that artificial saliva yielded medium-derived pellicles on resin surfaces, which provided attenuating effects on biofilms similar to salivary pellicles. Compared with the commercial control, the DMADDM-containing bonding agent reduced biofilm CFU by about two orders of magnitude. Novel DMADDM- and NAg-containing bonding agents substantially reduced biofilm growth even with salivary pellicle coating on surfaces, indicating a promising usage in saliva-rich environment. DMADDM and NAg may be useful in a wide range of primers, adhesives and other restoratives to achieve antibacterial and anti-caries capabilities. Published by Elsevier Ltd.
Bhatia, Hind P; Sood, Shveta; Sharma, Naresh
2017-01-01
Aim To evaluate and compare the sorption, solubility, and compressive strength of three different glass ionomer cements in artificial saliva - type IX glass ionomer cement, silver-reinforced glass ionomer cement, and zirconia-reinforced glass ionomer cement, so as to determine the material of choice for stress-bearing areas. Materials and methods A total of 90 cylindrical specimens (4 mm diameter and 6 mm height) were prepared for each material following the manufacturer’s instructions. After subjecting the specimens to thermocycling, 45 specimens were immersed in artificial saliva for 24 hours for compressive strength testing under a universal testing machine, and the other 45 were evaluated for sorption and solubility, by first weighing them by a precision weighing scale (W1), then immersing them in artificial saliva for 28 days and weighing them (W2), and finally dehydrating in an oven for 24 hours and weighing them (W3). Results Group III (zirconomer) shows the highest compressive strength followed by group II (Miracle Mix) and least compressive strength is seen in group I (glass ionomer cement type IX-Extra) with statistically significant differences between the groups. The sorption and solubility values in artificial saliva were highest for glass ionomer cement type IX - Extra-GC (group I) followed by zirconomer-Shofu (group III), and the least value was seen for Miracle Mix-GC (group II). Conclusion Zirconia-reinforced glass ionomer cement is a promising dental material and can be used as a restoration in stress-bearing areas due to its high strength and low solubility and sorption rate. It may be a substitute for silver-reinforced glass ionomer cement due to the added advantage of esthetics. Clinical significance This study provides vital information to pediatric dental surgeons on relatively new restorative materials as physical and mechanical properties of the new material are compared with conventional materials to determine the best suited material in terms of durability, strength and dimensional stability. This study will boost confidence among dental surgeons in terms of handling characteristics, cost effectiveness and success rate. This study will help clinically and scientifically; pediatric dental surgeons to use this material in stress-bearing areas in pediatric patients. How to cite this article Bhatia HP, Singh S, Sood S, Sharma N. A Comparative Evaluation of Sorption, Solubility, and Com-pressive Strength of Three Different Glass Ionomer Cements in Artificial Saliva: An in vitro Study. Int J Clin Pediatr Dent 2017;10(1):49-54. PMID:28377656
Effects of Chewing Different Flavored Gums on Salivary Flow Rate and pH.
Karami Nogourani, Maryam; Janghorbani, Mohsen; Kowsari Isfahan, Raha; Hosseini Beheshti, Mozhgan
2012-01-01
Chewing gum increases salivary flow rate (SFR) and pH, but differences in preferences of gum flavor may influence SFR and pH. The aim of this paper was to assess the effect of five different flavors of sucrose-free chewing gum on the salivary flow rate and pH in healthy dental students in Isfahan, Iran. Fifteen (7 men and 8 women) healthy dental student volunteers collected unstimulated saliva and then chewed one of five flavored gums for 6 min. The whole saliva was collected and assessed for 6 consecutive days. After unstimulated saliva was collected, stimulated saliva was collected at interval of 0-1, 1-3, and 3-6 minutes after the start of different flavored chewing gums. The SFR and salivary pH were measured. The SFR increased in all five flavored gums at 1, 3, and 6 minutes after start of chewing gums (P < 0.001). The flow rate of all products reached peak in the 1st minute of stimulation, except spearmint-flavored gums which reached peak in the 6th minute. In the 1st minute, the strawberry-flavored gums showed the highest SFR. During 1-3 minutes, strawberry- and apple-flavored gums showed higher SFR, respectively. Only the spearmint- and cinnamon-flavored gum significantly increased salivary pH. Gum flavored can affect the SFR and pH and special flavors can be advised for different individuals according to their oral conditions.
Balan, Preethi; B Gogineni, Subhas; Kumari N, Sucheta; Shetty, Veena; Lakshman Rangare, Anusha; L Castelino, Renita; Areekat K, Fazil
2015-01-01
Background and aims. The aim of this study was to establish a relationship between salivary glucose levels and Candida carriage rate in type 2 diabetes mellitus patients and assess the growth characteristics and acid production of Candida in glucose-supplemented saliva. Materials and methods . A total of 90 subjects, 30 with controlled type 2 diabetes, 30 with uncontrolled type 2 diabetes and 30 without diabetes (control subjects), aged 30‒60 years, participated in the study. Unstimulated saliva was collected and investigated for glucose levels (GOD-POD method), colony-forming units (CFU) of Candida and salivary pH, using Indikrom paper strips). Analysis of statistical significance of salivary glucose and PH levels was carried out using post hoc Tukey HSD test. Correlation of Candida carriage rate with salivary glucose and salivary PH in the study groups and control group was made using Pearson's correlation. Results. Candida CFUs were significantly higher in diabetic subjects, with a significant and positive correlation with salivary glucose levels. There was a negative correlation between salivary PH levels and Candida carriage rate. Conclusion. Increased salivary glucose was associated with increased prevalence of oral Candida in diabetic subjects. The growth of Candida in saliva was accompanied by a rapid decline in PH, which in turn favored their growth.
Hegde, Rahul J; Thakkar, Janhavi B
2017-01-01
This study aimed to compare and evaluate the changes in the salivary flow rate, pH, and buffering capacity before and after chewing casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and xylitol-containing chewing gums in children. Sixty children aged between 8 and 12 years were selected for the study. They were randomly divided into Group 1 (CPP-ACP chewing gum) and Group 2 (xylitol-containing chewing gum) comprising thirty children each. Unstimulated and stimulated saliva samples at 15 and 30 min interval were collected from all children. All the saliva samples were estimated for salivary flow rate, pH, and buffering capacity. Significant increase in salivary flow rate, pH, and buffering capacity from baseline to immediately after spitting the chewing gum was found in both the study groups. No significant difference was found between the two study groups with respect to salivary flow rate and pH. Intergroup comparison indicated a significant increase in salivary buffer capacity in Group 1 when compared to Group 2. Chewing gums containing CPP-ACP and xylitol can significantly increase the physiochemical properties of saliva. These physiochemical properties of saliva have a definite relation with caries activity in children.
[The physicochemical and microbiological characteristics of saliva during and after pregnancy].
Martínez-Pabón, María C; Martínez Delgado, Cecilia M; López-Palacio, Ana M; Patiño-Gómez, Lina M; Arango-Pérez, Eduin A
2014-01-01
Identify the changes in some physiological and microbiological parameters in the saliva from a group of women during and after their pregnancies. Stimulated whole saliva was collected from a cohort of 35 women during their pregnancy and afterwards to determine each sample's physicochemical (secretion rate, pH and buffer capacity) and microbiological characteristics (acidogenic bacteria count). The pH and buffer capacity of saliva during pregnancy were lower than after pregnancy. There were no statistically significant changes regarding S. mutans and Lactobacillus spp. count, but a tendency towards increased values during pregnancy was noted. Changes occurring in the saliva of pregnant women can lead to an increase of risk of suffering disease affecting one's oral health, such as caries, gingivitis and periodontal disease; this could be prevented by appropriate diagnosis and dental follow-up, including education regarding pregnant women's oral health.
pH salivary analysis of subjects suffering from Sjögren's syndrome and laryngopharyngeal reflux.
Corvo, Marco Antonio Dos Anjos; Eckley, Claudia Alessandra; Liquidato, Bianca Maria; Castilho, Gustavo Leão; Arruda, Cibelle Nunes de
2012-02-01
Saliva is one of the components for the digestive homeostasis. Recent studies have shown that patients with laryngopharyngeal reflux (LPR) present a drop in salivary pH. Patients with Sjögren's syndrome (SS) are a potential clinical research model for xerostomia and its laryngeal and pharyngeal consequences. The aim was to evaluate the characteristics of saliva of patients with SS and LPR. 19 patients with SS plus LPR, and 12 healthy controls had their saliva studied prospectively for volume and pH. Two salivary samples were obtained from each participant: whole unstimulated saliva(WUS) and whole stimulated saliva(WSS) while chewing parafilm M®. All the participants were females. Mean age was 60 years (study group) and 44 years (control). LPR was diagnosed on all 19 subjects. The mean pH of WUS was 7.53 (SS) and 7.57 (controls), raising to 7.87 and 7.83 respectively after stimulation. The mean salivary volume of patients with SS was 1.27 mL (WUS) and 3.78 mL (WSS), whereas controls had a significantly higher salivary volume both before and after stimuli. A very high prevalence of LPR was found in patients with SS, which is probably caused by a uniform drop in salivary volume and all its contents, rather than a specific deficiency in its components, as shown previously in patients without SS.
Kuriakose, S; Sundaresan, C; Mathai, V; Khosla, E; Gaffoor, F M A
2013-01-01
This study was conducted to identify various factors in the development of rampant type of dental caries in South Kerala children, other than high sucrose intake and poor oral hygiene. This was done by comparing the salivary buffering capacity(BC), flow-rate(FR), resting pH and salivary immunoglobulin-A(s-IgA) levels in children who are caries resistant(CR) and who have rampant dental caries. Two study groups, a rampant caries group(RC) with more than five active caries lesions in the early stages and a CR with no caries lesions were selected based on a specific criteria. Unstimulated whole mixed saliva was collected directly from the floor of the mouth for a period of 10 min and the FR was calculated. Resting pH of saliva was measured using color coded pH paper. BC was measured by calculating the amount of citric acid of pH2.5, required to lower the initial pH of saliva down to 3. s-IgA levels were also estimated by immunoturbidometric method after forming a precipitate of s-IgA with specific anti-IgA antibodies. The salivary BC, FRs, pH and s-IgA levels were significantly lower in the RC group when compared to the CR group. This study showed that salivary BC, flow-rate, resting pH and levels of s-IgA in saliva are risk factors in the development of RC in children.
Corrosion behaviour of high copper dental amalgams.
Yap, A U J; Ng, B L; Blackwood, D J
2004-06-01
This study evaluated the corrosion behaviour of two high copper dental amalgam alloys [Dispersalloy (Dentsply-Caulk) and Tytin (Kerr)] in different electrolytes. Amalgam specimens were prepared, coupled to a copper wire, cemented into glass tubes and polished to a 600-grit finish. A corrosion cell was prepared using a carbon counter-electrode, a standard calomel electrode as the reference and amalgam as the working electrode. The alloys were tested in the following mediums at 37 degrees C: (i) artificial saliva based on Fusayama's solution (FS), (ii) artificial saliva with citric acid adjusted to pH 4.0 (FC) and (iii) 1% sodium chloride solution (SC). Corrosion potentials (E(corr)) and corrosion rates (I(corr)) were determined using potentiostatic and impedance spectroscopy methods. Data was subjected to anova/Scheffe's post hoc test at 0.05 significance level. For both alloys, the corrosion potential in FS was significantly greater than in SC. Corrosion potential of Tytin in FS and SC was also significantly greater than in FC. The corrosion rate of Dispersalloy in FC was significantly greater than in FS and SC. For Tytin, corrosion rate in SC was significantly greater than in FS and FC. Although no significant difference in corrosion potential/rate was observed between the alloys when tested in FS, significant differences were observed when electrochemical testing was carried out in FC and SC. The corrosion behaviour of high copper amalgam alloys are both material and environment dependent. Certain food substances may increase the corrosion of high copper amalgams.
Salivary gland dysfunction markers in type 2 diabetes mellitus patients.
Aitken-Saavedra, Juan; Rojas-Alcayaga, Gonzalo; Maturana-Ramírez, Andrea; Escobar-Álvarez, Alejandro; Cortes-Coloma, Andrea; Reyes-Rojas, Montserrat; Viera-Sapiain, Valentina; Villablanca-Martínez, Claudia; Morales-Bozo, Irene
2015-10-01
Diabetes mellitus (DM) is a chronic disease of the carbohydrate metabolism that, when not rigorously controlled, compromises systemic and organ integrity, thereby causing renal diseases, blindness, neuropathy, arteriosclerosis, infections, and glandular dysfunction, including the salivary glands. The aim of this study was to determine the relationship between the qualitative and quantitative parameters of salivary alteration, which are indicators of salivary gland dysfunction, and the level of metabolic control of type 2 diabetes patients. A convenience sample of 74 voluntary patients with type 2 DM was selected, each of whom donated a sample of unstimulated saliva. Salivary parameters such as salivary flow rate, protein concentration, pH, and xerostomia were studied. There is a positive relationship between the level of metabolic control measured with HbA1 and the protein concentration in saliva (Spearman rho = 0.329 and p = 0.004). The same assay showed an inverse correlation between HbA1 and pH (Spearman rho = -0.225 and p = 0.05). The protein concentration in saliva and, to a lesser extent, the pH may be useful as glandular dysfunction indicators in DM2 patients. Saliva, type 2 diabetes mellitus, pH, protein concentration, xerostomia.
The effect of thiopental sodium, methoxyflurane and halothane on the acid-base status in sheep.
Edjtehadi, M; Howard, B R
1978-01-01
Experiments have been carried out on 20 adult fat-tailed ewes to determine the effects of thiopental sodium, methoxyflurane and halothane on acid-base status of the saliva loss during prolonged surgical anaesthesia. The rate of loss of base in saliva depends on the volume of saliva produced, which fell sharply at the onset of anesthesia with the volatile anaesthesia. Plasma pH and plasma pvCO2 excess were both increased by the volatile anaesthetics but fell sharply during thiopental anaesthesia. Plasma pH and plasma PvCO2 showed no consistent relationship. PMID:688076
Hardness of enamel exposed to Coca-Cola and artificial saliva.
Devlin, H; Bassiouny, M A; Boston, D
2006-01-01
The purpose of this study was to determine the rate of change in indentation hardness of enamel in permanent teeth exposed to Coca-Cola. In a further experiment, the ability of a commercially available artificial saliva to remineralize enamel treated with Coca-Cola was tested. Ten enamel specimens were randomly chosen to be treated with Coca-Cola (experimental groups) and seven with water (control group). The fluids were applied for 1, 2, 3 h and overnight (15 h), washed off with a few drops of water and the moist enamel indentation hardness tested after each interval. With Coca-Cola treatment, the mean enamel hardness was 92.6% (s.d. = 7.9) of the original baseline hardness after 1 h, 93.25% (s.d. = 10.15) after 2 h, 85.7% (s.d. = 12.03) after 3 h and 80.3% after 15 h. The mean indentation hardness of control specimens treated with water was 108.7% (s.d. = 16.09) of the original hardness after 1 h, 99.09% (s.d. = 18.98) after 2 h, 98.97% (s.d. =11.24) after 3 h and 98.42% (s.d. = 22.78) after 15 h. In a separate experiment, the hardness of 9 enamel specimens was tested, as previously described, before and after treatment with Coca-Cola overnight and again after application of artificial saliva for 3 min. Coca-Cola reduced the mean indentation hardness of enamel in the teeth, but the hardness was partially restored with artificial saliva (Salivart) and increased by 18% from the demineralized enamel hardness.
Jithesh, C; Venkataramana, V; Penumatsa, Narendravarma; Reddy, S N; Poornima, K Y; Rajasigamani, K
2015-08-01
To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable.
Jithesh, C.; Venkataramana, V.; Penumatsa, Narendravarma; Reddy, S. N.; Poornima, K. Y.; Rajasigamani, K.
2015-01-01
Objectives: To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Materials and Methods: Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. Result: The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. Conclusion: The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable. PMID:26538924
Corrosion of orthodontic brackets in different spices: in vitro study.
Chaturvedi, T P
2014-01-01
Moist environment in the mouth varies and causes variable amounts of corrosion of dental materials. This is of concern particularly when metallic implants, metallic fillings, orthodontic appliances are placed in the hostile electrolytic environment in the human mouth. Components of diet rich in salt and spices are important factors influencing the corrosion of metallic appliances placed in the oral cavity. To study in vitro corrosion of orthodontic metallic brackets immersed in solutions of salt and spices in artificial saliva. Orthodontic brackets were used for corrosion studies in artificial saliva, salt, and spices using electrochemical technique and surface analysis. Electrochemical studies using different parameters were done in solutions of artificial saliva containing salt and spices. Photomicrographs from the optical microscope were also obtained. RESULTS of corrosion studies have clearly demonstrated that certain spices such as turmeric and coriander are effective in reducing corrosion, whereas salt and red chili have been found to enhance it. Surface analysis of small pits present on the surface of the as-received bracket will initiate corrosion which leads to more pitting.
Mendes-Sousa, Antonio Ferreira; Nascimento, Alexandre Alves Sousa; Queiroz, Daniel Costa; Vale, Vladimir Fazito; Fujiwara, Ricardo Toshio; Araújo, Ricardo Nascimento; Pereira, Marcos Horácio; Gontijo, Nelder Figueiredo
2013-01-01
Lutzomyia longipalpis is the vector of Leishmania infantum in the New World, and its saliva inhibits classical and alternative human complement system pathways. This inhibition is important in protecting the insect´s midgut from damage by the complement. L. longipalpis is a promiscuous blood feeder and must be protected against its host's complement. The objective of this study was to investigate the action of salivary complement inhibitors on the sera of different host species, such as dogs, guinea pigs, rats and chickens, at a pH of 7.4 (normal blood pH) and 8.15 (the midgut pH immediately after a blood meal). We also investigated the role of the chicken complement system in Leishmania clearance in the presence and absence of vector saliva. The saliva was capable of inhibiting classical pathways in dogs, guinea pigs and rats at both pHs. The alternative pathway was not inhibited except in dogs at a pH of 8.15. The chicken classical pathway was inhibited only by high concentrations of saliva and it was better inhibited by the midgut contents of sand flies. Neither the saliva nor the midgut contents had any effect on the avian alternative pathway. Fowl sera killed L. infantum promastigotes, even at a low concentration (2%), and the addition of L. longipalpis saliva did not protect the parasites. The high body temperature of chickens (40°C) had no effect on Leishmania viability during our assays. Salivary inhibitors act in a species-specific manner. It is important to determine their effects in the natural hosts of Leishmania infantum because they act on canid and rodent complements but not on chickens (which do not harbour the parasite). Moreover, we concluded that the avian complement system is the probable mechanism through which chickens eliminate Leishmania and that their high body temperature does not influence this parasite.
An Optical Sensor with Polyaniline-Gold Hybrid Nanostructures for Monitoring pH in Saliva.
Luo, Chongdai; Wang, Yangyang; Li, Xuemeng; Jiang, Xueqin; Gao, Panpan; Sun, Kang; Zhou, Jianhua; Zhang, Zhiguang; Jiang, Qing
2017-03-17
Saliva contains important personal physiological information that is related to some diseases, and it is a valuable source of biochemical information that can be collected rapidly, frequently, and without stress. In this article, we reported a new and simple localized surface plasmon resonance (LSPR) substrate composed of polyaniline (PANI)-gold hybrid nanostructures as an optical sensor for monitoring the pH of saliva samples. The overall appearance and topography of the substrates, the composition, and the wettability of the LSPR surfaces were characterized by optical and scanning electron microscope (SEM) images, infrared spectra, and contact angles measurement, respectively. The PANI-gold hybrid substrate readily responded to the pH. The response time was very short, which was 3.5 s when the pH switched from 2 to 7, and 4.5 s from 7 to 2. The changes of visible-near-infrared (NIR) spectra of this sensor upon varying pH in solution showed that-for the absorption at given wavelengths of 665 nm and 785 nm-the sensitivities were 0.0299 a.u./pH (a.u. = arbitrary unit) with a linear range of pH = 5-8 and 0.0234 a.u./pH with linear range of pH = 2-8, respectively. By using this new sensor, the pH of a real saliva sample was monitored and was consistent with the parallel measurements with a standard laboratory method. The results suggest that this novel LSPR sensor shows great potential in the field of mobile healthcare and home medical devices, and could also be modified by different sensitive materials to detect various molecules or ions in the future.
Neutralizing salivary pH by mouthwashes after an acidic challenge.
Dehghan, Mojdeh; Tantbirojn, Daranee; Kymer-Davis, Emily; Stewart, Colette W; Zhang, Yanhui H; Versluis, Antheunis; Garcia-Godoy, Franklin
2017-05-01
The aim of the present study was to test the neutralizing effect of mouthwashes on salivary pH after an acidic challenge. Twelve participants were recruited for three visits, one morning per week. Resting saliva was collected at baseline and after 2-min swishing with 20 mL orange juice as an acidic challenge. Participants then rinsed their mouth for 30 s with 20 mL water (control), an over-the-counter mouthwash (Listerine), or a two-step mouthwash, randomly assigned for each visit. Saliva was collected immediately, 15, and 45 min after rinsing. The pH values of the collected saliva were measured and analyzed with anova, followed by Student-Newman-Keuls post-hoc test (significance level: 0.05). Orange juice significantly lowered salivary pH. Immediately after rinsing, Listerine and water brought pH back to baseline values, with the pH significantly higher in the Listerine group. The two-step mouthwash raised pH significantly higher than Listerine and water, and higher than the baseline value. Salivary pH returned to baseline and was not significantly different among groups at 15 and 45 min post-rinsing. Mouth rinsing after an acidic challenge increased salivary pH. The tested mouthwashes raised pH higher than water. Mouthwashes with a neutralizing effect can potentially reduce tooth erosion from acid exposure. © 2015 Wiley Publishing Asia Pty Ltd.
Susceptibility of anthocyanins to ex vivo degradation in human saliva
Kamonpatana, Kom; Giusti, M. Mónica; Chitchumroonchokchai, Chureeporn; MorenoCruz, Maria; Riedl, Ken M.; Kumar, Purnima; Failla, Mark L.
2013-01-01
Some fruits and their anthocyanin-rich extracts have been reported to exhibit chemopreventive activity in the oral cavity. Insights regarding oral metabolism of anthocyanins remain limited. Anthocyanin-rich extracts from blueberry, chokeberry, black raspberry, red grape, and strawberry were incubated ex vivo with human saliva from 14 healthy subjects. All anthocyanins were partially degraded in saliva. Degradation of chokeberry anthocyanins in saliva was temperature dependent and decreased by heating saliva to 80 °C and after removal of cells. Glycosides of delphinidin and petunidin were more susceptible to degradation than those of cyanidin, pelargonidin, peonidin and malvidin in both intact and artificial saliva. Stability of di- and tri-saccharide conjugates of anthocyanidins slightly, but significantly, exceeded that of monosaccharide compounds. Ex vivo degradation of anthocyanins in saliva was significantly decreased after oral rinsing with antibacterial chlorhexidine. These results suggest that anthocyanin degradation in the mouth is structure-dependent and largely mediated by oral microbiota. PMID:22868153
Wu, Katie P; Ke, Jyh-Yuh; Chung, Chia-Ying; Chen, Chia-Ling; Hwang, Tsong-Long; Chou, Ming-Yen; Wong, Alice M K; Hu, Ching-Fang; Lee, Yu-Cheng
2008-01-01
Saliva is one of the most important factors in regulating oral health, with flow rate and composition changing throughout development and during disease. In view of the shortage of data, the present study aimed to shed light on the relationship between unstimulated salivary flow rate and saliva composition of healthy children in Taiwan. Forty-four normal, healthy children from 3-14 years of age were divided into three age groups: pre-school, elementary school and junior-high school. All participants received salivary flow rate, pH and saliva composition analysis under unstimulated conditions. One-way ANOVA and Pearson's correlation were used. Statistical significance was set at p < 0.05. Our results suggest that, under unstimulated conditions, the salivary flow rate of the elementary school group was greater than that of the pre-school group (p < 0.05). No difference in pH was found among the three groups. Intergroup salivary calcium, phosphorus and amylase did not reach statistical difference. As the flow rate increased, the pH increased (r = 0.364, p < 0.05) but the protein level decreased (r = -0.473, p < 0.05). In addition, salivary protein was positively correlated to age (r = 0.479, p < 0.05) and negatively correlated to pH (r = -0.361, p < 0.01). Age-related increase in the unstimulated salivary flow rate of pre-school and elementary school groups was noted. As the flow rate increased, the pH increased but the protein level decreased. The information obtained may serve as reference values for the growing interest in saliva as a diagnostic tool, especially monitoring those with neurological or oral motor dysfunction.
A device for the collection of submandibular saliva.
Hanning, Sara; Motoi, Lidia; Medlicott, Natalie; Swindells, Stephen
2012-03-01
The objective of this study was to describe the construction of a non-invasive device for the collection of submandibular saliva. Preliminary tests were carried out on saliva collected from a single donor in order to determine whether the rheological properties of submandibular saliva collected using the device were comparable to whole saliva collected using the expectoration (or 'spit') method. The device collected a lower quantity of saliva than that collected using the expectoration method. Stimulated saliva collected using the device had a pH close to that of unstimulated saliva because the sealed collection unit in the device minimised contamination. Saliva exhibited shear-thinning behaviour regardless of the method of collection, although that collected using the device was more viscous. The viscoelasticity of saliva collected using the two methods was different, probably as a result of differences in composition. This difference was greater with stimulated saliva. Despite the discrepancies between whole saliva and submandibular saliva, the device provides a non-invasive method for the collection of high-quality saliva over extended periods.
Muchandi, Sneha; Walimbe, Hrishikesh; Bijle, Mohammed Nadeem Ahmed; Nankar, Meenakshi; Chaturvedi, Srishti; Karekar, Priyanka
2015-03-01
Dental caries is a major problem in preschool children. The contribution of saliva in providing defense during caries process is of primary importance. pH buffer capacity through bicarbonate, phosphate and protein buffer systems have universal acceptance as a caries defense mechanism. Antioxidant capacity of saliva can constitute a first line of defense against chronic degenerative diseases including dental caries. Till date, no study is presented with salivary antioxidant capacity of younger children affected with severe early childhood caries with its salivary pH correlation. Hence, this study was carried out to compare, evaluate and correlate the salivary total antioxidant capacity (TAC) and salivary pH of children with caries-free and severe early childhood caries. Fifty children from ages 3 to 5 years divided into two study groups had undergone screening. Group I (n = 25) with severe early childhood caries (S-ECC) and group II (n = 25) who were caries free. Unstimulated whole saliva of subjects were in the collection during the study by draining method. Salivary pH determination of saliva samples was done using pH indicator paper strips. The TAC was done using an antioxidant assay with the help of a spectrophotometer at wavelength 532 nm. The means of salivary pH and TAC were subjected to analysis using unpaired student 't' test and correlation was determined using Pearsons correlation coefficient analysis. Mean salivary pH was higher in group II (7.46 ± 0.37). Mean TAC was greater in group I (1.82 ± 0.19). A statistically significant negative correlation as seen between TAC and salivary pH in S-ECC patients. The study concludes that salivary TAC increases in patients with S-ECC are by that showing a high indirect relationship with salivary pH.
Salivary pH: A diagnostic biomarker.
Baliga, Sharmila; Muglikar, Sangeeta; Kale, Rahul
2013-07-01
Saliva contains a variety of host defense factors. It influences calculus formation and periodontal disease. Different studies have been done to find exact correlation of salivary biomarkers with periodontal disease. With a multitude of biomarkers and complexities in their determination, the salivary pH may be tried to be used as a quick chairside test. The aim of this study was to analyze the pH of saliva and determine its relevance to the severity of periodontal disease. The study population consisted of 300 patients. They were divided into three groups of 100 patients each: Group A had clinically healthy gingiva, Group B who had generalized chronic gingivitis and Group C who had generalized chronic periodontitis. The randomized unstimulated saliva from each patient was collected and pH was tested. Data was analyzed statistically using analysis of variance technique. The salivary pH was more alkaline for patients with generalized chronic gingivitis as compared with the control group (P = 0.001) whereas patients with generalized chronic periodontitis had more acidic pH as compared with the control group (P = 0.001). These results indicate a significant change in the pH depending on the severity of the periodontal condition. The salivary pH shows significant changes and thus relevance to the severity of periodontal disease. Salivary pH may thus be used as a quick chairside diagnostic biomarker.
Evaluation of Solubility and Microleakage of Glass Carbomer Sealant.
Subramaniam, P; Girish Babu, K L; Jayasurya, S
2015-01-01
This study was carried out to evaluate and compare solubility and microleakage of the newly introduced moisture tolerant glass carbomer sealant. For evaluation of solubility, 20 specimens of glass carbomer and conventional glass ionomer were prepared and immersed in artificial saliva of pH 4 and 6 for seven days. The difference between initial and final weight was calculated. For evaluation of microleakage, glass carbomer was compared with a conventional resin sealant. 20 premolar teeth indicated for orthodontic extraction were collected and divided into two groups and the respective sealants were applied. It was subjected to thermocycling and then kept immersed in methylene blue for 24 hours. Dye penetration was scored. The glass carbomer specimens were less soluble than the conventional glass ionomer at both pH values. There was no significant difference in the microleakage. Being moisture resistant, glass carbomer can be used as an alternative fissure sealant material; especially in young children with partially erupted teeth and where obtaining moisture control is difficult.
SEM and EDX Study of Stainless Steels, Suggested as Human Body Implants
NASA Astrophysics Data System (ADS)
Simitchiiska, R. N.; Ivanova, D.; Fachikov, L.
2018-06-01
The most important requirement for any material used as an implant is to be biocompatible and not to cause undesirable effects in the human body. Corrosion of implants is included in the topic of biocompatibility because it is a determining factor in their sustainability and seamless fulfillment of their functional purpose. The work presents the results obtained in the comparative study of two austenitic stainless steels (Cr18Ni9 and Cr18Mn12N) in two models of artificial saliva, accepted as environments for testing the corrosion behavior of materials for these aims. The nature of the corrosion attack, the composition of the corrosion products at 37°C and the pH 5.5 and pH 6.75 of the model media were determined using physical methods such as SEM and EDX of investigation and analysis. It was found that Cr18Mn12N steel (0.61 % N), exhibits higher corrosion resistance.
Laboratory investigations into the potential anticaries efficacy of fluoride varnishes.
Lippert, Frank; Hara, Anderson Takeo; Martinez-Mier, Esperanza Angeles; Zero, Domenick T
2014-01-01
The purpose of this study was to investigate the potential anticaries efficacy of fluoride varnishes (FVs) by studying their ability to reharden and deliver fluoride to carious lesions and to release fluoride into saliva. Enamel carious lesions were created and allocated to 24 groups (11 FVs with two FV incubation times and two control groups) based on Knoop microhardness test values. FVs were applied to lesions, which were incubated in artificial saliva for two or six hours, with saliva being renewed hourly. FV was removed and lesions were remineralized in artificial saliva for 22 hours. Microhardness was measured and enamel fluoride uptake (EFU) was determined. Saliva samples (six-hour groups) were analyzed to determine fluoride release characteristics. Data were analyzed using analysis of variance. FVs differed considerably in their ability to reharden and deliver fluoride to carious lesions and in their fluoride release characteristics. Little consistency was found between investigated study variables for virtually all tested FVs. For example, a particular FV showed the highest EFU and fluoride release values but the lowest rehardening value. A longer FV contact time led to increased EFU for five of the 11 FVs. Some FVs delivered more fluoride to lesions in two hours than others did in six hours. Fluoride varnishes differ greatly in their in vitro anticaries efficacy.
Salivary gland dysfunction markers in type 2 diabetes mellitus patients
Aitken-Saavedra, Juan; Rojas-Alcayaga, Gonzalo; Maturana-Ramírez, Andrea; Escobar-Álvarez, Alejandro; Cortes-Coloma, Andrea; Reyes-Rojas, Montserrat; Viera -Sapiain, Valentina; Villablanca-Martínez, Claudia
2015-01-01
Background Diabetes mellitus (DM) is a chronic disease of the carbohydrate metabolism that, when not rigorously controlled, compromises systemic and organ integrity, thereby causing renal diseases, blindness, neuropathy, arteriosclerosis, infections, and glandular dysfunction, including the salivary glands. The aim of this study was to determine the relationship between the qualitative and quantitative parameters of salivary alteration, which are indicators of salivary gland dysfunction, and the level of metabolic control of type 2 diabetes patients. Material and Methods A convenience sample of 74 voluntary patients with type 2 DM was selected, each of whom donated a sample of unstimulated saliva. Salivary parameters such as salivary flow rate, protein concentration, pH, and xerostomia were studied. Results There is a positive relationship between the level of metabolic control measured with HbA1 and the protein concentration in saliva (Spearman rho = 0.329 and p = 0.004). The same assay showed an inverse correlation between HbA1 and pH (Spearman rho = -0.225 and p = 0.05). Conclusions The protein concentration in saliva and, to a lesser extent, the pH may be useful as glandular dysfunction indicators in DM2 patients. Key words:Saliva, type 2 diabetes mellitus, pH, protein concentration, xerostomia. PMID:26535097
Elevated Incidence of Dental Caries in a Mouse Model of Cystic Fibrosis
Catalán, Marcelo A.; Scott-Anne, Kathleen; Klein, Marlise I.; Koo, Hyun; Bowen, William H.; Melvin, James E.
2011-01-01
Background Dental caries is the single most prevalent and costly infectious disease worldwide, affecting more than 90% of the population in the U.S. The development of dental cavities requires the colonization of the tooth surface by acid-producing bacteria, such as Streptococcus mutans. Saliva bicarbonate constitutes the main buffering system which neutralizes the pH fall generated by the plaque bacteria during sugar metabolism. We found that the saliva pH is severely decreased in a mouse model of cystic fibrosis disease (CF). Given the close relationship between pH and caries development, we hypothesized that caries incidence might be elevated in the mouse CF model. Methodology/Principal Findings We induced carious lesions in CF and wildtype mice by infecting their oral cavity with S. mutans, a well-studied cariogenic bacterium. After infection, the mice were fed a high-sucrose diet for 5 weeks (diet 2000). The mice were then euthanized and their jaws removed for caries scoring and bacterial counting. A dramatic increase in caries and severity of lesions scores were apparent in CF mice compared to their wildtype littermates. The elevated incidence of carious lesions correlated with a striking increase in the S. mutans viable population in dental plaque (20-fold increase in CF vs. wildtype mice; p value<0.003; t test). We also found that the pilocarpine-stimulated saliva bicarbonate concentration was significantly reduced in CF mice (16±2 mM vs. 31±2 mM, CF and wildtype mice, respectively; p value<0.01; t test). Conclusions/Significance Considering that bicarbonate is the most important pH buffering system in saliva, and the adherence and survival of aciduric bacteria such as S. mutans are enhanced at low pH values, we speculate that the decrease in the bicarbonate content and pH buffering of the saliva is at least partially responsible for the increased severity of lesions observed in the CF mouse. PMID:21304986
A Comparative Study of Bio Degradation of Various Orthodontic Arch Wires: An In Vitro Study
Gopikrishnan, S; Melath, Anil; Ajith, V V; Mathews, N Binoy
2015-01-01
Background: Orthodontic wires are the corner stones of the science and art of orthodontics and they remain in the patient’s mouth for a prolonged period of 18-24 months. It is but natural to expect that they will undergo some biodegradation when in the oral environment during that period. This study aims to compare the biodegradation characteristics of four different orthodontic wires, stainless steel, nickel titanium (NiTi), titanium molybdenum alloy (TMA), and copper NiTi and to assess whether these biodegradation products, are within acceptable limits. Materials and Methods: This study involved the incubation of four different wires in artificial saliva and analyzing the amount of metal released from them at the end of a 28 days study period. The metals analyzed for where nickel, chromium, copper, cobalt, manganese, iron, molybdenum, and titanium. The artificial saliva was changed on days 7, 14, and 21 to prevent the saturation of metals in the artificial saliva. At the end of 28 days, these four samples of artificial saliva of each wire were mixed together and analyzed for the eight metals using an inductively coupled plasma spectroscope. Results: The results showed only the release of nickel, chromium, and iron from stainless steel wire, nickel from NiTi wire, nickel, and chromium from copper NiTi and none from TMA wire. Conclusion: The metals released from arch wires are of such minute quantities to be of any biologic hazard. The amount of metals released is well within acceptable biocompatible limits. Though this study has analyzed the biodegradation of various orthodontic wires, orthodontic wires are never used alone in mechanotherapy. Orthodontic wires along with multiband appliance system with which it is always used and in combination with accessories like face bows may release more metals. PMID:25709360
Microcomputed tomography evaluation of white spot lesion remineralization with various procedures.
Kucuk, Eyup Burak; Malkoc, Siddik; Demir, Abdullah
2016-09-01
The aim of this study was to use microcomputed tomography to evaluate the effects on white spot lesions of 3 remineralizing agents compared with artificial saliva (Inonu University, Malatya, Turkey). The agents were GC Tooth Mousse (GC International, Itabashi-ku, Tokyo, Japan), 50-ppm sodium fluoride solution (Inonu University, Malatya, Turkey), and Clinpro 5000 (3M ESPE Dental Products (St Paul, Minn). The experimental and control teeth were stored in artificial saliva. Forty-four extracted premolars were divided into 4 groups of 11 teeth each (3 experimental groups and 1 control group). After white spot lesions were created on the teeth, a remineralizing agent was applied. Microcomputed tomography scanning was performed at the following times: T0 (sound enamel), T1 (day 0, when the white spot lesion was formed), T2 (day 15), and T3 (day 30). Volume, depth, surface area, and mineral density changes of the white spot lesions were evaluated at different time points using CTAn software (SkyScan; Bruker, Kontich, Belgium). GC Tooth Mousse and Clinpro 5000 improved all measurements after 30 days. However, Clinpro 5000 was not as effective in reducing lesion depth as it was in the other parameters. The artificial saliva group and the 50-ppm sodium fluoride solution did not show significant effects in the regression of the white spot lesions at the end of the 30-day experiment. GC Tooth Mousse and Clinpro 5000 were more effective in remineralization of white spot lesions than sodium fluoride solution and artificial saliva. They can be preferred for use clinically. Microcomputed tomography is a novel and effective method that shows promise in accurately evaluating white spot lesions and remineralization. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Will, Torsten; Steckbauer, Kathrin; Hardt, Martin; van Bel, Aart J. E.
2012-01-01
In order to separate and analyze saliva types secreted during stylet propagation and feeding, aphids were fed on artificial diets. Gel saliva was deposited as chains of droplets onto Parafilm membranes covering the diets into which watery saliva was secreted. Saliva compounds collected from the diet fluid were separated by SDS-PAGE, while non-soluble gel saliva deposits were processed in a novel manner prior to protein separation by SDS-PAGE. Soluble (watery saliva) and non-soluble (gel saliva) protein fractions were significantly different. To test the effect of the stylet milieu on saliva secretion, aphids were fed on various diets. Hardening of gel saliva is strongly oxygen-dependent, probably owing to formation of sulfide bridges by oxidation of sulphydryl groups. Surface texture of gel saliva deposits is less pronounced under low-oxygen conditions and disappears in dithiothreitol containing diet. Using diets mimicking sieve-element sap and cell-wall fluid respectively showed that the soluble protein fraction was almost exclusively secreted in sieve elements while non-soluble fraction was preferentially secreted at cell wall conditions. This indicates that aphids are able to adapt salivary secretion in dependence of the stylet milieu. PMID:23056521
NASA Astrophysics Data System (ADS)
McCarroll, Louise; Solomon, Michael; Schultz, William
2016-11-01
Oral and even systemic health begins with healthy saliva by maintaining antibacterial activity, lubricating hard and soft oral tissues, healing, tasting, chewing, and swallowing. Saliva functionality is intimately linked to its rheology. Alterations in saliva rheology may indicate or cause unhealthy biological function. One imprecise pathological designation is "sticky saliva", usually self-reported or qualitatively described by health professionals. Saliva is 99% water and therefore behaves like water in shear. Saliva also contains mucins, electrolytes, enzymes, hormones, and antibodies. These additional constituents enable saliva to form a long-lasting filament with a "beads-on-a-string" morphology in extension. Therefore, the main kinematic feature that distinguishes the coupling between the oral cavity and saliva elongational mechanics. We investigate the effect of pH and salinity on saliva filament formation with preliminary experiments and compare to 1D unsteady viscoelastic models. We discuss the results in the context of saliva functionality and in generating more satisfactory saliva substitutes for those suffering from xerostomia. We will discuss when beads-on-a-string are likely to occur.
Khemiss, Mehdi; Ben Khelifa, Mohamed; Ben Saad, Helmi
2017-12-01
The aim of the present comparative study was to compare some salivary characteristics between exclusive waterpipe smokers (EWPS) and non-smokers. 72 males (36 EWPS) were recruited. The volume of stimulated saliva was determined and divided by the duration of saliva collection. The pH was measured directly using a pH meter. The buffering capacity was determined using a quantitative method which involved the addition of 10 µl HCl. Up to a total of 160 µL was titrated up to obtain a pH titration curve. At 50 µL of titrated HCl, buffering capacity was ranked into three categories: high, medium and low. EWPS and non-smoker groups had similar flow rates (1.81 ± 0.79 and 1.78 ± 1.14 mL min-1) and similar baseline pH (6.60 ± 0.37 and 6.76 ± 0.39). Statistically significant differences in the two groups' pH were observed from 30 to 160 µL of titrated up HCl. At 50 µL of titrated up HCl, the EWPS group compared to the non-smoker group had a significantly higher pH (4.79 ± 0.72 vs. 5.32 ± 0.79). To conclude, waterpipe tobacco smoking alters the buffering capacity but does not alter either salivary flow rates or the baseline pH and consistency.
Dermal exposure potential from textiles that contain silver nanoparticles
Stefaniak, Aleksandr B; Duling, Mathew G; Lawrence, Robert B; Thomas, Treye A; LeBouf, Ryan F; Wade, Eleanor E; Abbas Virji, M
2014-01-01
Background: Factors that influence exposure to silver particles from the use of textiles are not well understood. Objectives: The aim of this study was to evaluate the influence of product treatment and physiological factors on silver release from two textiles. Methods: Atomic and absorbance spectroscopy, electron microscopy, and dynamic light scattering (DLS) were applied to characterize the chemical and physical properties of the textiles and evaluate silver release in artificial sweat and saliva under varying physiological conditions. One textile had silver incorporated into fiber threads (masterbatch process) and the other had silver nanoparticles coated on fiber surfaces (finishing process). Results: Several complementary and confirmatory analytical techniques (spectroscopy, microscopy, etc.) were required to properly assess silver release. Silver released into artificial sweat or saliva was primarily in ionic form. In a simulated “use” and laundering experiment, the total cumulative amount of silver ion released was greater for the finishing process textile (0.51±0.04%) than the masterbatch process textile (0.21±0.01%); P<0.01. Conclusions: We found that the process (masterbatch vs finishing) used to treat textile fibers was a more influential exposure factor than physiological properties of artificial sweat or saliva. PMID:25000110
Dermal exposure potential from textiles that contain silver nanoparticles.
Stefaniak, Aleksandr B; Duling, Mathew G; Lawrence, Robert B; Thomas, Treye A; LeBouf, Ryan F; Wade, Eleanor E; Virji, M Abbas
2014-01-01
Factors that influence exposure to silver particles from the use of textiles are not well understood. The aim of this study was to evaluate the influence of product treatment and physiological factors on silver release from two textiles. Atomic and absorbance spectroscopy, electron microscopy, and dynamic light scattering (DLS) were applied to characterize the chemical and physical properties of the textiles and evaluate silver release in artificial sweat and saliva under varying physiological conditions. One textile had silver incorporated into fiber threads (masterbatch process) and the other had silver nanoparticles coated on fiber surfaces (finishing process). Several complementary and confirmatory analytical techniques (spectroscopy, microscopy, etc.) were required to properly assess silver release. Silver released into artificial sweat or saliva was primarily in ionic form. In a simulated "use" and laundering experiment, the total cumulative amount of silver ion released was greater for the finishing process textile (0·51±0·04%) than the masterbatch process textile (0·21±0·01%); P<0·01. We found that the process (masterbatch vs finishing) used to treat textile fibers was a more influential exposure factor than physiological properties of artificial sweat or saliva.
Saini, Rajesh; Kotian, Ravindra; Madhyastha, Prashanthi; Srikant, N
2016-01-01
The objective of this study was to compare the sorption and solubility of heat-cure and self-cure acrylic resins in different solutions. One heat-cure acrylic resin (Trevalon) and one self-cure acrylic resin (Rapid Repair) were studied. Five groups of square-shaped specimens (20 mm × 20 mm × 2 mm) were prepared for each acrylic resin and then immersed in five solutions: distilled water, artificial saliva, denture cleansing solution, distilled water, and denture cleaning solution for 12 h alternatively, artificial saliva and denture cleaning solution for 12 h alternatively at 37 ± 2°C, and tested sorption and solubility by weight gain/loss method, respectively, after 1, 6, and 11 weeks. The data were analyzed by one-way analysis of variance followed by post hoc Tukey's test. Water sorption mean values varied from 17.5 ± 0.88 to 27.25 ± 1.04 μg/mm 3 for heat cure and from 12.75 ± 0.55 to 19.75 ± 1.04 μg/mm 3 for self-cure in the different solutions after different interval periods of 1, 6, and 11 weeks. These values were statistically significant (P< 0.001). Water solubility mean values varied from 0.25 ± 0.55 to 1.5 ± 0.55 μg/mm 3 for heat cure and from 1.5 ± 0.55 to 6.5 ± 0.55 μg/mm 3 for self-cure in the different solutions after different interval periods of 1, 6, and 11 weeks. These values were statistically not significant (P > 0.05). There was no linear correlation between sorption and solubility values. Overall, analysis of results showed the maximum sorption value in denture cleansing solution followed by alternative soaking in distilled water and artificial saliva. Least sorption was observed with artificial saliva followed by distilled water. Both heat-cure and self-cure acrylic resins showed varying water sorption and solubility. The results of both water sorption and solubility showed compliance with the International Standards Organization specification. No correlation was found between water sorption and solubility. Artificial saliva solution is a better storage medium than distilled water and denture cleansing solution for both heat-cure and self-cure acrylic resins.
Oral yeast colonization throughout pregnancy
Rio, Rute; Simões-Silva, Liliana; Garro, Sofia; Silva, Mário-Jorge; Azevedo, Álvaro
2017-01-01
Background Recent studies suggest that placenta may harbour a unique microbiome that may have origin in maternal oral microbiome. Although the major physiological and hormonal adjustments observed in pregnant women lead to biochemical and microbiological modifications of the oral environment, very few studies evaluated the changes suffered by the oral microbiota throughout pregnancy. So, the aim of our study was to evaluate oral yeast colonization throughout pregnancy and to compare it with non-pregnant women. Material and Methods The oral yeast colonization was assessed in saliva of 30 pregnant and non-pregnant women longitudinally over a 6-months period. Demographic information was collected, a non-invasive intra-oral examination was performed and saliva flow and pH were determined. Results Pregnant and non-pregnant groups were similar regarding age and level of education. Saliva flow rate did not differ, but saliva pH was lower in pregnant than in non-pregnant women. Oral yeast prevalence was higher in pregnant than in non-pregnant women, either in the first or in the third trimester, but did not attain statistical significance. In individuals colonized with yeast, the total yeast quantification (Log10CFU/mL) increase from the 1st to the 3rd trimester in pregnant women, but not in non-pregnant women. Conclusions Pregnancy may favour oral yeast growth that may be associated with an acidic oral environment. Key words:Oral yeast, fungi, pregnancy, saliva pH. PMID:28160578
Saliva pH as a biomarker of exam stress and a predictor of exam performance.
Cohen, Miri; Khalaila, Rabia
2014-11-01
Salivary pH is regulated by the sympathetic and parasympathetic nervous system; therefore, it may serve as a biomarker of stress. To assess the associations between the cognitive and emotional dimensions of exam stress and pH levels, and the predictability of salivary pH in relation to test performance. A prospective study. Eighty-three nursing students answered a questionnaire on stress appraisals, experienced stress, test anxiety (including worry and emotionality subscales) and health behaviors, and gave a saliva sample for measuring pH on the morning of their first term exam and three months later. Their performance on the test (grades) was also recorded. Levels of pH in saliva were higher (levels of acidity were lower) in the post exam compared to the exam period, in parallel to lower threat appraisal, experienced stress, and test anxiety levels post exam. Controlling for smoking, physical activity and working hours per week, pH levels at both time points were predicted by appraised threat regarding the exam situation, experienced stress, and the emotionality dimension of test anxiety. pH at Time 1 predicted performance on the exams and mediated the associations of experienced stress and emotionality subscale with test performance. the present study indicates that pH levels may serve as a reliable, accessible and inexpensive means by which to assess the degree of physiological reactions to exams and other naturalistic stressors. Copyright © 2014 Elsevier Inc. All rights reserved.
Muddugangadhar, B. C.; Sangur, Rajashekar; Rudraprasad, I. V.; Nandeeshwar, D. B.; Kumar, B. H. Dhanya
2015-01-01
Purpose: This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Materials and Methods: Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Results: Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Conclusion: Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. Clinical Implications: The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics. PMID:26929540
Muddugangadhar, B C; Sangur, Rajashekar; Rudraprasad, I V; Nandeeshwar, D B; Kumar, B H Dhanya
2015-01-01
This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics.
In vitro assessment of a toothpaste range specifically designed for children.
Churchley, David; Schemehorn, Bruce R
2013-12-01
To evaluate the ability of a range of low abrasivity experimental toothpastes designed for use by children at different stages of their development (typically ages 0-2 years, 3-5 years and 6+ years) to promote fluoride uptake and remineralisation of artificial caries lesions. pH cycling study: demineralised human permanent enamel specimens were subjected to a daily pH cycling regime consisting of four 1-minute treatments with toothpaste slurries, a 4-hour acid challenge and remineralisation in pooled whole human saliva. Surface microhardness (SMH) was measured at baseline, 10 days and 20 days, and the fluoride content determined at 20 days. Enamel Fluoride Uptake (EFU): these studies were based on Method #40 described in the US Food and Drug Administration (FDA) testing procedures. Abrasivity: relative enamel abrasivity (REA) and relative dentine abrasivity (RDA) were measured using the Hefferren abrasivity test. Bioavailable fluoride: the bioavailable fluoride was determined for all experimental toothpastes from slurries of one part toothpaste plus 10 parts deionised water. Enamel remineralisation measured by changes in SMH correlated with enamel fluoride content. A statistically significant fluoride dose response was observed for all toothpastes tested across all age groups (P < 0.05). The fluoride content of specimens in the pH cycling model correlated with the EFU testing results. The enamel and dentine abrasivities were low and the level of bioavailable fluoride was high for all experimental toothpastes. A series of low abrasivity experimental toothpastes were developed which were effective at promoting fluoride uptake and remineralisation of artificial caries lesions. © 2013 FDI World Dental Federation.
Anand, Siddharth; Masih, Updesh; Yeluri, Ramakrishna
If a relation exists between salivary I PHA , buffer capacity and caries experience, then this relationship could be used as screening chair side test for caries risk assessment. One hundred ninety seven children aged 4 to 6 years were examined. Data was collected by interview and clinical examination. They were divided into low, moderate and high caries experience group of 20 children each. Two ml of each sample was used to measure the pH value with pH meter. Regarding the buffering capacity, freshly prepared hydrochloric acid (HCl) was titrated into saliva and pH was recorded. The collected saliva samples were sent to Laboratory for measurement of calcium and phosphorus. I PHA was calculated and the negative logarithms of I PHA were used to determine the enamel solubility. The correlation between salivary I PHA , buffering capacity and caries experience were evaluated. There was a significant relation between pH, log I PHA and dental caries experience, it could be considered as a predictor of dental caries. pH measurement after HCl titration in saliva could be used as chair side screening test for the assessment of caries risk.
Bardow, Allan; Lykkeaa, Joan; Qvist, Vibeke; Ekstrand, Kim; Twetman, Svante; Fiehn, Niels-Erik
2014-08-01
It was hypothesized that, by comparing matched subjects with major differences in these dental diseases, but yet normal saliva flow rates, it would be possible to obtain data on the effect of saliva composition on dental disease isolated from the effect of the flow rate. Thus, the aim of the study was to compare the major physicochemical characteristics of stimulated whole saliva in three groups of 85 subjects, each with normal saliva flow rates and at least 24 remaining teeth. A group with very little dental disease (healthy), a group with dental erosion (erosion) and a group with very high caries experience (caries) were chosen. Furthermore, the aim was to determine whether differences among groups could also be found on an individual level. Although it was not possible to retrieve three groups whose members were completely identical, the present study points in the direction that, on a group level, subjects with very little dental disease seemed to have a more favorable physicochemical saliva composition with respect to higher calcium, phosphate, bicarbonate, pH, degree of saturation with respect to hydroxyapatite and a lower critical pH (p < 0.05 or less). However, on an individual level the explanatory power for the saliva composition was only 10% for caries experience and only 11% for dental erosion (p < 0.001). The compositional analyses performed in this study on stimulated whole saliva, including major physicochemical characteristics of saliva, will most likely have little predictive value for future dental caries and erosion in single individuals.
Murugesh, Jeevitha; Annigeri, Rajeshwari G; Raheel, Syed Ahmed; Azzeghaiby, Saleh; Alshehri, Mohammad; Kujan, Omar
2015-12-01
Xerostomia is a common clinical problem, and different medications have been tried in its management. In the present study, routine dietary products are used to assess their effect on salivary flow. To assess the efficacy of yogurt and lemon juice on increase in salivation and its comparison with that of unstimulated saliva. A total of 40 volunteers (aged 19-48) were selected. The pH of yogurt was calculated, and equivalent pH lemon juice was prepared. First, normal resting saliva was collected as baseline followed by every 1 min for 5 min. Patients were given lemon juice or yogurt and then crossed over to the other group to assess the impact of the stimulants on salivary flow from 1 to 5 min. The results were analyzed statistically. Comparisons between baseline saliva secretion and that by yogurt and lemon juice (using the ANOVA test) showed that there was a significant increase after treatment at the end of the experiment for both yogurt and lemon juice. However, yogurt showed a significant increase in saliva secretion compared to baseline than lemon juice. Our findings suggest that yogurt is a potential candidate for the treatment of dry mouth.
Ahmadi-Motamayel, Fatemeh; Amjad, Samaneh Vaziri; Goodarzi, Mohammad Taghi; Poorolajal, Jalal
2018-01-01
Antioxidants protect the body against cellular damage. Saliva has immunological, enzymatic and antioxidant defense systems. Uric acid is the main and predominant salivary antioxidant. The aim of this study was to evaluate salivary uric acid levels and pH in HIV-infected patients in the west of Iran. HIV-infected patients were selected from behavioral advisory centers of Hamadan and Kermanshah Provinces, west of Iran. Saliva was collected between 8 and10 in the morning. Five mL of whole unstimulated saliva was collected in 5 minutes by spitting into sterilized Falcon tubes based on Navazesh method; pH was measured with a pH meter and uric acid was assessed with spectrophotometric method. Data were analyzed with STATA 12. Salivary pH in the HIV-positive group was lower (6.99±0.46) than the healthy controls (7.14±1.03) but the difference was not statistically significant (P=380). Uric acid concentrations in HIV-infected patients (2.94±2.14) were significantly lower in comparison to the healthy controls (5.21±2.30). The results showed a statistically significant decrease in the case group (P=0.001). Mean age and DMFT index of the case group were higher than the control group. Uric acid, the main antioxidant of saliva, was significantly lower in HIVinfected individuals; pH also was lower in these patients. HIV can alter salivary antioxidant status, which can influence patients' oral health status. Diet with antioxidant properties might be helpful in these patients. More research is necessary to discover true antioxidant and salivary changes and their relation with HIV consequences in future. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Hosseinzadeh Nik, T; Ghadirian, H; Ahmadabadi, M Nili; Shahhoseini, T; Haj-Fathalian, M
2012-01-01
Most published results about the characteristics of NiTi wires are based on the mechanical laboratory tests on the as-received wires.The purpose of this study was to investigate the effect of saliva on load-deflection characteristics of superelastic NiTi wires. In this experimental study, 15 wires of three kinds of superelastic NiTi wires (Sentalloy, Force I and Truflex) were prepared. Five specimens of each wire were tested in the as-received condition (T0) to provide baseline information and the remaining wires were divided into two groups of five. Half of them were kept inside artificial saliva for one month (T1), while the others were kept in air (T2). After 30 days, three-point bending test was done in a dental arch model and data from selected points on the unloading phase of the generated graphs were used for statistical analysis. Force I and Truflex showed significantly greater force than Sentalloy. The load values of Truflex and Force I after one month exposed to artificial saliva (T1) decreased significantly, but Sentalloy was not affected significantly. The plateau gap values were not considerably different among T0, T1 and T2. Saliva decreased the load of Force I and Truflex significantly, but it did not have a statistically significant effect on Sentalloy.
Ye, A; Streicher, C; Singh, H
2011-12-01
Whey protein beverages have been shown to be astringent at low pH. In the present study, the interactions between model whey proteins (β-lactoglobulin and lactoferrin) and human saliva in the pH range from 7 to 2 were investigated using particle size, turbidity, and ζ-potential measurements and sodium dodecyl sulfate-PAGE. The correlation between the sensory results of astringency and the physicochemical data was discussed. Strong interactions between β-lactoglobulin and salivary proteins led to an increase in the particle size and turbidity of mixtures of both unheated and heated β-lactoglobulin and human saliva at pH ∼3.4. However, the large particle size and high turbidity that occurred at pH 2.0 were the result of aggregation of human salivary proteins. The intense astringency in whey protein beverages may result from these increases in particle size and turbidity at these pH values and from the aggregation and precipitation of human salivary proteins alone at pH <3.0. The involvement of salivary proteins in the interaction is a key factor in the perception of astringency in whey protein beverages. At any pH, the increases in particle size and turbidity were much smaller in mixtures of lactoferrin and saliva, which suggests that aggregation and precipitation may not be the only mechanism linked to the perception of astringency in whey protein. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Khemiss, Mehdi; Ben Khelifa, Mohamed; Ben Saad, Helmi
2017-01-01
ABSTRACT The aim of the present comparative study was to compare some salivary characteristics between exclusive waterpipe smokers (EWPS) and non-smokers. 72 males (36 EWPS) were recruited. The volume of stimulated saliva was determined and divided by the duration of saliva collection. The pH was measured directly using a pH meter. The buffering capacity was determined using a quantitative method which involved the addition of 10 µl HCl. Up to a total of 160 µL was titrated up to obtain a pH titration curve. At 50 µL of titrated HCl, buffering capacity was ranked into three categories: high, medium and low. EWPS and non-smoker groups had similar flow rates (1.81 ± 0.79 and 1.78 ± 1.14 mL min-1) and similar baseline pH (6.60 ± 0.37 and 6.76 ± 0.39). Statistically significant differences in the two groups’ pH were observed from 30 to 160 µL of titrated up HCl. At 50 µL of titrated up HCl, the EWPS group compared to the non-smoker group had a significantly higher pH (4.79 ± 0.72 vs. 5.32 ± 0.79). To conclude, waterpipe tobacco smoking alters the buffering capacity but does not alter either salivary flow rates or the baseline pH and consistency. PMID:28266252
Terahertz pulsed imaging study to assess remineralization of artificial caries lesions
NASA Astrophysics Data System (ADS)
Churchley, David; Lynch, Richard J. M.; Lippert, Frank; O'Bryan Eder, Jennifer Susan; Alton, Jesse; Gonzalez-Cabezas, Carlos
2011-02-01
We compare terahertz-pulsed imaging (TPI) with transverse microradiography (TMR) and microindentation to measure remineralization of artificial caries lesions. Lesions are formed in bovine enamel using a solution of 0.1 M lactic acid/0.2% Carbopol C907 and 50% saturated with hydroxyapatite adjusted to pH 5.0. The 20-day experimental protocol consists of four 1 min treatment periods with dentifrices containing 10, 675, 1385, and 2700 ppm fluoride, a 4-h/day acid challenge, and, for the remaining time, specimens are stored in a 50:50 pooled human/artificial saliva mixture. Each specimen is imaged at the focal point of the terahertz beam (data-point spacing = 50 μm). The time-domain data are used to calculate the refractive index volume percent profile throughout the lesion, and the differences in the integrated areas between the baseline and post-treatment profiles are used to calculate ΔΔZ(THz). In addition, the change from baseline in both the lesion depth and the intensity of the reflected pulse from the air/enamel interface is determined. Statistically significant Pearson correlation coefficients are observed between TPI and TMR/microindentation (P < 0.05). We demonstrate that TPI has potential as a research tool for hard tissue imaging.
Is salivary pH a marker of depression among older spousal caregivers for cancer patients?
Khalaila, Rabia; Cohen, Miri; Zidan, Jamal
2014-01-01
The pH in saliva, which decreases due to the activation of the sympathetic nervous system, may serve as a biomarker of psychological distress in caregivers but has rarely been studied in this context. The aims are to examine the levels of salivary pH as a possible biomarker of depression among caregivers and whether depression mediates the association between caregiving status (cancer caregivers vs. non-cancer caregivers) and pH levels. Cross-sectional data were collected from 68 consecutive-sampled spouses of cancer patients, and 42 age-matched individuals. Lower levels of pH saliva were found among caregivers of cancer patients than in the comparison group. Being a caregiver, poor subjective health, higher depression, and lower mastery predicted lower pH levels. In addition, depression mediated the associations of mastery with pH levels. The study provides preliminary evidence that salivary pH may serve as an easily tested indicator of the stress of caregiving and its related depression.
da Silva Modesto, Karine Barros; de Godói Simões, Jéssica Bueno; de Souza, Amanda Ferreira; Damaceno, Neiva; Duarte, Danilo Antonio; Leite, Mariana Ferreira; de Almeida, Eliete Rodrigues
2015-11-01
It is recognized that cystic fibrosis (CF) patients present a risk for oral diseases, since it affects exocrine glands, and the treatment consists of a carbohydrate-rich diet. Recognizing the protective function of saliva on maintaining oral health, the aim of the study was to evaluate salivary parameters in stimulated whole saliva from children with CF. A case-control study was conducted comparing stimulated whole saliva of healthy (n=28; control group) and CF children (n=21; experimental group). Salivary flow rate, initial pH, buffer capacity (total and in each range of pH), total protein and sialic acid (total, free, and conjugated) concentration, α-amylase and salivary peroxidase activities were evaluated. Data were compared by two-tailed Student t test (95% CI; p ≤ 0.05). CF patients presented a significant reduction in salivary parameters compared with the control group (p ≤ 0.05): salivary flow rate (36%), buffer capacity (pH range from 6.9 to 6.0), sialic acid concentration (total 75%, free 61%, and conjugated 83%); α-amylase and salivary peroxidase activities (55%). Additionally, a significant increase in total protein concentration (180%) of stimulated whole saliva from CF patients was verified compared with the control group (p ≤ 0.05). Children with CF presented significant changes in salivary composition, including salivary flow rate, buffering capacity and protective proteins of the oral cavity, compared with children without CF. Copyright © 2015 Elsevier Ltd. All rights reserved.
Effect of Fluoride on Nickel-Titanium and Stainless Steel Orthodontic Archwires: An In-Vitro Study
Heravi, Farzin; Moayed, Mohamad Hadi; Mokhber, Nima
2015-01-01
Objectives: The commonly used Nickel-Titanium (NiTi) archwires in orthodontic treatment are often exposed to fluoride-containing mouthwashes. The aim of this in-vitro study was to evaluate and compare the corrosion resistance of three commercially available NiTi archwires exposed to 0.05 wt% and 0.2 wt% fluoride mouthwashes. Materials and Methods: Three different types of NiTi archwires, 0.016″ in diameter, from Dentaurum, Global, and GAC, and a stainless steel archwire from Dentaurum were examined to assess their corrosion resistance in Fusayama-Meyer artificial saliva and in two other artificial saliva containing 0.05 wt% and 0.2 wt% sodium fluoride (NaF). After the primary setup of wires, they were tested by potentiodynamic and potentiostatic polarization and corrosion potential/time analyses. Their surfaces were evaluated using a scanning electronic microscope (SEM). Results: The results showed that all the wires were passive in artificial saliva. In contrast, by adding fluoride ions to the solution, the decrease in the archwires’ corrosion resistance was in direct proportion to the increase in fluoride concentration. Conclusion: The NiTi wires experienced deterioration of their corrosion properties under the effect of fluoride but not as much as the stainless steel archwires. PMID:26005454
Efficacy of herbal toothpastes on salivary pH and salivary glucose - A preliminary study.
Khairnar, Mahesh R; Dodamani, Arun S; Karibasappa, G N; Naik, Rahul G; Deshmukh, Manjiri A
Due to dearth of literature on the effect of herbal toothpaste on saliva and salivary constituents, the present study was undertaken to evaluate and compare the effect of three different herbal toothpastes with the focus on on salivary pH and salivary glucose. Forty five subjects in the age group of 19-21 years were randomly divided into 3 groups (15 in each group) and were randomly intervened with three different herbal toothpastes (Dant Kanti, Himalaya Complete Care and Vicco Vajradanti). Unstimulated saliva samples were collected before and after brushing and salivary glucose and pH levels were assessed at an interval of one week each for a period of 4 weeks starting from day 1. All the three toothpastes were effective in reducing the overall (p < 0.05) levels as well as levels of salivary glucose from pre-brushing to post-brushing at each interval (p < 0.05) and in increasing the overall levels as well as levels of salivary pH (p < 0.05) from pre-brushing to post-brushing at each interval. Herbal toothpastes were effective in reducing salivary levels of glucose and improving pH of the saliva. Copyright © 2016 Transdisciplinary University, Bangalore and World Ayurveda Foundation. Published by Elsevier B.V. All rights reserved.
Wang, Xian-li; Guo, Tian-wen
2012-09-01
To study the corrosion resistance of casted titanium by plasma nitriding and TiN-coated compound treatments in the artificial saliva with different fluoride concentrations and to investigate whether compound treatments can increase the corrosion resistance of casted titanium. Potentiodynamic polarization technique was used to depict polarization curve and to measured the current density of corrosion (Icorr) and the electric potential of corrosion (Ecorr) of casted titanium (Group A) and casted titanium by compound treatments (Group B) in the artificial saliva with different fluoride concentrations. After electrochemical experiment, the microstructure was observed by scanning electron microscope (SEM). The Icorrs of Group A and B in the artificial saliva of different fluoride concentrations were (1530.23 ± 340.12), (2290.36 ± 320.10), (4130.52 ± 230.17) nA and (2.62 ± 0.64), (7.37 ± 3.59), (10.76 ± 6.05) nA, respectively. The Ecorrs were (-0.93 ± 0.10), (-0.89 ± 0.21), (-0.57 ± 0.09) V and (-0.21 ± 0.04), (-0.17 ± 0.03), (-0.22 ± 0.03) V, respectively.The Icorrs of Group B were significantly lower (P < 0.01)than that of Group A. The Icorrs increased significantly with the increasing of fluoride concentrations (P < 0.01). The Ecorrs of Group B were significantly higher than that of Group A (P < 0.01). The SEM confirmed the microstructure in the casted titanium was much severely than that in Group B, the microstructure in Group A and B corroded more and more heavily with increasing of fluoride concentrations. The increase of fluoride concentrations influence the corrosion resistance of both treated and untreated casted titanium negatively, but plasma nitriding and TiN-coated compound treatments can significantly increase the corrosion resistance of casted titanium.
Murugesh, Jeevitha; Annigeri, Rajeshwari G.; Raheel, Syed Ahmed; Azzeghaiby, Saleh; Alshehri, Mohammad; Kujan, Omar
2015-01-01
Background Xerostomia is a common clinical problem, and different medications have been tried in its management. In the present study, routine dietary products are used to assess their effect on salivary flow. Aim To assess the efficacy of yogurt and lemon juice on increase in salivation and its comparison with that of unstimulated saliva. Materials and Methods A total of 40 volunteers (aged 19–48) were selected. The pH of yogurt was calculated, and equivalent pH lemon juice was prepared. First, normal resting saliva was collected as baseline followed by every 1 min for 5 min. Patients were given lemon juice or yogurt and then crossed over to the other group to assess the impact of the stimulants on salivary flow from 1 to 5 min. Results The results were analyzed statistically. Comparisons between baseline saliva secretion and that by yogurt and lemon juice (using the ANOVA test) showed that there was a significant increase after treatment at the end of the experiment for both yogurt and lemon juice. However, yogurt showed a significant increase in saliva secretion compared to baseline than lemon juice. Conclusions Our findings suggest that yogurt is a potential candidate for the treatment of dry mouth. PMID:26767120
Assessment of the pharmacodynamics of intranasal, intravenous and oral scopolamine
NASA Technical Reports Server (NTRS)
Tietze, Karen J.
1990-01-01
Space motion sickness is an important issue in the space medical sciences program. One of the objectives of the ongoing clinical experimental protocol Pharmacokinetics of Intranasal Scopolamine in Normal Subjects is to evaluate the pharmacodynamics of scopolamine using salivary flow rate and pH profiles and cognitive performance tests as pharmacodynamic parameters. Normal volunteers collected saliva and performed the NTI Multiresource Performance Battery tests at designed time intervals to establish control saliva flow rates, salivary pH profiles, and the characteristics of the learning curve for the performance program under normal conditions. In the clinical part of the study, saliva samples and performance test scores are collected from healthy nonsmoking subjects after receiving a single 0.4 mg dose of either intranasal, intravenous, or oral scopolamine.
Shahabi, M; Jahanbin, A; Esmaily, H; Sharifi, H; Salari, S
2011-01-01
Resistance to corrosion is an advantageous property of orthodontic brackets; however, due to low levels of pH found in the mouth of a patient, localized corrosion may occur This can affect tooth movement by increasing friction between the arch wire and bracket slot and initiate enamel discoloration. Additionally, corrosion causes the release of elements that may lead to cytotoxic and biological side effects. The aim of this study was to compare the amount of corrosion caused by lemon juice, vinegar and Coca-Cola on orthodontic brackets in vitro and then to recommend the most suitable diet during orthodontic treatment. Sixty orthodontic brackets in three groups of twenty were immersed in a test solution (Fusamaya-Meyer artificial saliva plus lemon juice, vinegar or Coca-Cola) at a temperature of 37 degrees C +/- 1. Moreover, a negative control consisting of twenty brackets were put in pure artificial saliva. After 6 weeks the amount of corrosion was determined by measuring delta W of mean weights of brackets and the results were analyzed by general linear models (repeated measurement). Significant differences were seen during different weeks of the study (P < 0.001) and different solutions (P < 0.001). This study showed the amount of corrosion in orthodontic brackets was the most for cola followed by vinegar and then lemon juice. In addition, mean differences for cola versus lemon juice was -0.010 (sig. <0.001), vinegar versus lemon juice was -0.006 (sig. = 0.001) and cola versus vinegar was -0.004 (sig. = 0.013). Acidic effervescent soft drinks such as cola have to be eliminated or minimized in the nutritional diet of orthodontic patients because of their harmful effects on their brackets.
S. sanguinis adhesion on rough titanium surfaces: effect of culture media.
Rodríguez-Hernández, Ana G; Muñoz-Tabares, José A; Godoy-Gallardo, Maria; Juárez, Antonio; Gil, Francisco-Javier
2013-03-01
Bacterial colonization plays a key role in dental implant failure, because they attach directly on implant surface upon implantation. Between different types of bacteria associated with the oral environment, Streptococcus sanguinis is essential in this process since it is an early colonizer. In this work the relationship between titanium surfaces modified by shot blasting treatment and S. sanguinis adhesion; have been studied in approached human mouth environment. Bacteria pre-inoculated with routinary solution were put in contact with titanium samples, shot-blasted with alumina and silicon carbide, and adhesion results were compared with those obtained when bacteria were pre-inoculated with modified artificial saliva medium and on saliva pre-coated titanium samples. Our results showed that bacterial adhesion on titanium samples was influenced by culture conditions. When S. sanguinis was inoculated in routinary culture media, colonies forming unities per square millimeter presented an increment correlated with roughness and surface energy, but separated by the type of particle used during shot-blasting treatment; whereas in modified artificial saliva only a relationship between bacteria adhered and the increment in both roughness and surface energy were observed, regardless of the particle type. Finally, on human saliva pre-coated samples no significant differences were observed among roughness, surface energy or particle. Copyright © 2012 Elsevier B.V. All rights reserved.
Medvecky, L; Stulajterova, R; Giretova, M; Mincik, J; Vojtko, M; Balko, J; Briancin, J
2018-03-01
To investigate the tubule occlusion and remineralization potential of a novel toothpaste with active tetracalcium phosphate/monetite mixtures under de/remineralization cycling. Dentin de/remineralization cycling protocol consisted of demineralization in 1% citric acid at pH 4.6 with following remineralization with toothpastes and soaking in artificial saliva. Effectiveness of toothpastes to promote remineralization was evaluated by measurement of microhardness recovery, analysis of surface roughness, thickness of coating and scanning electron microscopy. The novel tetracalcium phosphate/monetite dentifrice had comparable remineralization potential as commercial calcium silicate/phosphate (SENSODYNE ® ) and magnesium aluminum silicate (Colgate ® ) toothpastes and significantly higher than control saliva (p<0.02). Surface roughness was significantly lower after treatment with prepared and SENSODYNE ® dentifirice (p<0.05). The coatings on dentin surfaces was significantly thicker after applying toothpastes as compared to negative control (p<0.001). The new fluoride toothpaste formulation with bioactive tetracalcium phosphate/monetite calcium phosphate mixture effectively occluded dentin tubules and showed good dentin remineralization potential under de/remineralization cycling. It could replace professional powder preparation based on this mixture. It was demonstrated that prepared dentifrice had comparable properties with commercial fluoride calcium silicate/phosphate or magnesium aluminum silicate dentifrices. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Effect of different fluoride varnishes on remineralization of artificial enamel carious lesions.
Mohd Said, Siti N B; Ekambaram, Manikandan; Yiu, Cynthia K Y
2017-05-01
To compare remineralization potential of topical fluoride varnishes with added calcium phosphate-based delivery systems on artificial enamel caries. Human enamel specimens (n = 60) were randomly divided into six groups: Group 0: Control (no varnish), Group 1: Duraphat ® , Group 2: MI Varnish ™ , Group 3: Embrace ™ Varnish, Group 4: Enamel Pro ® Varnish, and Group 5: Clinpro ™ White Varnish. Specimens were immersed in demineralizing solution for 96 h to create artificial caries lesion. Each specimen was then immersed in artificial saliva for 6 h after fluoride varnish application and pH cycling was performed for 8 days. Specimens were evaluated using Knoop surface microhardness (KHN) and transverse microradiography (TMR). One-way anova test was performed to examine the effect of fluoride varnishes on change in percentage of surface hardness recovery (%SHR), change in lesion depth (ΔLD), and change in mineral loss (ΔΔZ) with the significance limit set at 5%. %SHR of enamel following treatment with Group 1 was significantly higher than Group 3 and Group 4. Conversely, ΔLD and ΔΔZ of Group 1 were significantly higher than Group 2, Group 3, and Group 4. No significant differences in %SHR, ΔLD, and ΔΔZ were found between Group 1 and Group 5. Duraphat ® alone achieves significant remineralization of enamel carious lesions. Clinpro ™ White Varnish had similar enamel remineralization effect as Duraphat ® . © 2016 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Toothbrushing after an erosive attack: will waiting avoid tooth wear?
Lussi, Adrian; Lussi, Jonas; Carvalho, Thiago S; Cvikl, Barbara
2014-10-01
The purpose of this study was to determine if storage for up to 4 h in human saliva results in a decrease of erosive tooth wear (ETW) and in an increase of surface microhardness (SMH) of enamel samples after an erosive attack with subsequent abrasion. Furthermore, we determined the impact of individual salivary parameters on ETW and SMH. Enamel samples were distributed into five groups: group 1 had neither erosion nor saliva treatment; groups 2-5 were treated with erosion, then group 2 was placed in a humid chamber and groups 3-5 were incubated in saliva for 30 min, 2 h, and 4 h, respectively. After erosion and saliva treatments, all groups were treated with abrasion. Surface microhardness and ETW were measured before and after erosion, incubation in saliva, and abrasion. Surface microhardness and ETW showed significant changes throughout the experiment: SMH decreased and ETW increased in groups 2-5, regardless of the length of incubation in saliva. The results of groups 3-5 (exposed to saliva) were not significantly different from those of group 2 (not exposed to saliva). Exposure of eroded enamel to saliva for up to 4 h was not able to increase SMH or reduce ETW. However, additional experiments with artificial saliva without proteins showed protection from erosive tooth wear. The recommendation to postpone toothbrushing of enamel after an erosive attack should be reconsidered. © 2014 Eur J Oral Sci.
2013-01-01
Background The purpose of this study was to assess the surface characterization and frictional resistance between stainless steel brackets and two types of orthodontic wires made of stainless steel and nickel-titanium alloys after immersion in a chlorhexidine-containing prophylactic agent. Methods Stainless steel orthodontic brackets with either stainless steel (SS) or heat-activated nickel-titanium (Ni-Ti) wires were immersed in a 0.2% chlorhexidine and an artificial saliva environment for 1.5 h. The frictional force was measured on a universal testing machine with a crosshead speed of 10 mm/min over a 5-mm of archwire. The surface morphology of bracket slots and surface roughness of archwires after immersion in chlorhexidine were also characterized using a scanning electron microscope (SEM) and an atomic force microscope (AFM), respectively. Results There was no significant difference in the frictional resistance values between SS and Ni-Ti wires immersed in either chlorhexidine or artificial saliva. The frictional resistance values for the SS and Ni-Ti wires immersed in 0.2% chlorhexidine solution were not significantly different from that inartificial saliva. No significant difference in the average surface roughness for both wires before (as-received) and after immersion in either chlorhexidine or artificial saliva was observed. Conclusions One-and-half-hour immersion in 0.2% chlorhexidine mouthrinse did not have significant influence on the archwires surface roughness or the frictional resistance between stainless steel orthodontic brackets and archwires made of SS and Ni-Ti. Based on these results, chlorhexidine-containing mouthrinses may be prescribed as non-destructive prophylactic agents on materials evaluated in the present study for orthodontic patients. PMID:24325758
The relationship between MMPs and pH in whole saliva of radiated head and neck cancer patients.
Vuotila, T; Ylikontiola, L; Sorsa, T; Luoto, H; Hanemaaijer, R; Salo, T; Tjäderhane, L
2002-07-01
Radiation therapy for head and neck tumour patients may lead to decreased salivary flow, oral mucosal lesions and increased caries experience. Salivary matrix metalloproteinases (MMPs) may participate in the pathogenesis of mucosal lesions and dentinal caries. The aims of this study were: (i) to assay the presence, molecular forms and proteolytic activity of MMP-8 (collagenase-2) and MMP-9 (gelatinase B) in the whole saliva of head and neck cancer patients having radiation therapy; (ii) to see whether salivary pH affects the activity of MMP-8 and MMP-9; and (iii) to find out the possible connection between MMP-8 and MMP-9 with the eruption of oral mucosal lesions during radiation therapy. The whole saliva samples of 39 head and neck cancer patients having radiation therapy were collected before, during and after radiation therapy, and saliva flow rate, pH, buffer capacity, Streptococcus mutans, Lactobacillus and Candida albicans were measured. Any oral mucosal lesions were examined during each visit. The levels of MMP-8 were measured by immunofluorometric assay (IFMA) and the presence of different MMP-8 forms was analysed using Western immunoblotting. The presence and molecular forms of MMP-9 were analyzed by gelatin zymography. MMP-9 capture activity assay was used to determine the APMA-activated MMP-9 activity (total) and the endogenously active MMP-9 (free activity). Salivary flow rate, buffer capacity and pH decreased, and the levels of Lactobacilli increased significantly, during the first half of the radiation therapy. The endogenously activated salivary MMP-9 correlated with low salivary pH (P = 0.013). No connection was found between the oral mucosal lesions and salivary MMP-8 or MMP-9. In this study, salivary MMP-8 or MMP-9 did not correlate with the presence of radiation induced oral mucosal lesions, but the activation of MMP-9 may be dependent on pH.
Paszyńska, Elzbieta; Słopień, Agnieszka; Slebioda, Zuzanna S; Dyszkiewicz-Konwińska, Marta; Weglarz, Monika; Rajewski, Andrzej
2014-01-01
The aim of the study was to evaluate the status of the oral mucosa, to assess the prevalence of Candida in the oral cavity and to analyze the pH values of total saliva in patients with anorexia nervosa (AN) in comparison to the general population. A controlled clinical trial was designed for two, age-matched, female groups: patients with AN (Group A, n=31) and healthy women (Group 0, n = 40). Total saliva was collected at rest and after stimulation by chewing paraffin wax. Salivary pH was measured and macroscopic evaluation of the oral mucosa was performed with a qualitative and quantitative mycological analysis. The smear layer was collected from three different areas in the oral cavity. Selected Candida broths were used for incubation. Changes in the macroscopic structure of the oral mucosa due to multifactorial etiologies were observed. The prevalence of Candida in patients with AN was comparable to that in the general population. Salivary pH values were significantly lower in the AN patients than in the control group. The incidence of pathological changes in the oral mucosa is associated with the loss of the salivary protective barrier. This is shown by the significant reduction in the pH values of stimulated and non-stimulated saliva of the AN patients. In these patients, the monitoring of salivary parameters such as salivary flow rate and pH is indicated, and a regular dental checkup, together with soft tissue evaluation, is advised.
Food acid content and erosive potential of sugar-free confections.
Shen, P; Walker, G D; Yuan, Y; Reynolds, C; Stacey, M A; Reynolds, E C
2017-06-01
Dental erosion is an increasingly prevalent problem associated with frequent consumption of acidic foods and beverages. The aim of this study was to measure the food acid content and the erosive potential of a variety of sugar-free confections. Thirty sugar-free confections were selected and extracts analysed to determine pH, titratable acidity, chemical composition and apparent degree of saturation with respect to apatite. The effect of the sugar-free confections in artificial saliva on human enamel was determined in an in vitro dental erosion assay using change in surface microhardness. The change in surface microhardness was used to categorize the confections as high, moderate or low erosive potential. Seventeen of the 30 sugar-free confections were found to contain high concentrations of food acids, exhibit low pH and high titratable acidity and have high erosive potential. Significant correlations were found between the dental erosive potential (change in enamel surface microhardness) and pH and titratable acidity of the confections. Ten of these high erosive potential confections displayed dental messages on the packaging suggesting they were safe for teeth. Many sugar-free confections, even some with 'Toothfriendly' messages on the product label, contain high contents of food acids and have erosive potential. © 2017 Australian Dental Association.
Tuna, Suleyman Hakan; Pekmez, Nuran Ozcícek; Keyf, Filiz; Canlí, Fulya
2009-01-01
Objectives: As the choice of suprastructure alloy to be combined with titanium for the oral cavity is still a much debated issue, the aim of this study was to investigate the electrochemical interaction of the suprastructure/implant couples under the determined experiment conditions. Material and Methods: The potentiodynamic polarization curves and open-circuit potentials (OCP) of four UCLA type suprastructures coupled with straight Swiss Plus implant fixtures were taken in Afnor type artificial saliva solution at 37°C. The concentration of ions leached into artificial saliva solutions was estimated with ICP-MS. SEM images of the margins of suprastructure/implant couples were obtained before and after the electrochemical tests. Results: The OCP value of titanium became passive at the most negative potential. The lowest difference between the initial and constant OCP value was exhibited by the Au based suprastructure. Suprastructures made greater contributions to the potentiodynamic polarization curves of the implant/suprastructure couples. According to the ICP-MS results, Pd based and Au based couples dissolved less than Co-Ni based and Co-Cr based couples. Conclusions: Within the conditions this study, it may be concluded that the titanium implant forms a stable passive oxide layer in artificial saliva exposed to open air and does not affect the corrosion properties of the suprastructures. Pd based and Au based couples have been found to be more corrosion-resistant than base alloy couples. PMID:19936528
Jamilian, Abdolreza; Moghaddas, Omid; Toopchi, Shabnam; Perillo, Letizia
2014-07-01
Oral environment of the mouth is a suitable place for biodegradation of alloys used in orthodontic wires. The toxicity of these alloys namely nickel and chromium has concerned the researchers about the release of these ions from orthodontic wires and brackets. The aim of this study was to measure the levels of nickel and chromium ions released from 0.018" stainless steel (SS) and NiTi wires after immersion in three solutions. One hundred and forty-four round NiTi and 144 round SS archwires with the diameters of 0.018" were immersed in Oral B®, Orthokin® and artificial saliva. The amounts of nickel and chromium ions released were measured after 1, 6, 24 hours and 7 days. Two way repeated ANOVA showed that the amount of chromium and nickel significantly increased in all solutions during all time intervals (p < 0.002). Chromium and nickel ions were released more in NiTi wire in all solutions compared with SS wire. The lowest increase rate was also seen in artificial saliva. There is general consensus in literature that even very little amounts of nickel and chromium are dangerous for human body specially when absorbed orally; therefore, knowing the precise amount of these ions released from different wires when immersed in different mouthwashes is of high priority.
Evaluation of force degradation characteristics of orthodontic latex elastics in vitro and in vivo.
Wang, Tong; Zhou, Gang; Tan, Xianfeng; Dong, Yaojun
2007-07-01
To evaluate the characteristics of force degradation of latex elastics in clinical applications and in vitro studies. Samples of 3/16-inch latex elastics were investigated, and 12 students between the ages of 12 and 15 years were selected for the intermaxillary and intramaxillary tractions. The elastics in the control groups were set in artificial saliva and dry room conditions and were stretched 20 mm. The repeated-measure two-way analysis of variance and nonlinear regression analysis were used to identify statistical significance. Overall, there were statistically significant differences between the different methods and observation intervals. At 24- and 48-hour time intervals, the force decreased during in vivo testing and in artificial saliva (P < .001), whereas there were no significant differences in dry room conditions (P > .05). In intermaxillary traction the percentage of initial force remaining after 48 hours was 61%. In intramaxillary traction and in artificial saliva the percentage of initial force remaining was 71%, and in room conditions 86% of initial force remained. Force degradation of latex elastics was different according to their environmental conditions. There was significantly more force degradation in intermaxillary traction than in intramaxillary traction. The dry room condition caused the least force loss. There were some differences among groups in the different times to start wearing elastics in intermaxillary traction but no significant differences in intramaxillary traction.
Variation in Aedes aegypti Mosquito Competence for Zika Virus Transmission.
Roundy, Christopher M; Azar, Sasha R; Rossi, Shannan L; Huang, Jing H; Leal, Grace; Yun, Ruimei; Fernandez-Salas, Ildefonso; Vitek, Christopher J; Paploski, Igor A D; Kitron, Uriel; Ribeiro, Guilherme S; Hanley, Kathryn A; Weaver, Scott C; Vasilakis, Nikos
2017-04-01
To test whether Zika virus has adapted for more efficient transmission by Aedes aegypti mosquitoes, leading to recent urban outbreaks, we fed mosquitoes from Brazil, the Dominican Republic, and the United States artificial blood meals containing 1 of 3 Zika virus strains (Senegal, Cambodia, Mexico) and monitored infection, dissemination, and virus in saliva. Contrary to our hypothesis, Cambodia and Mexica strains were less infectious than the Senegal strain. Only mosquitoes from the Dominican Republic transmitted the Cambodia and Mexica strains. However, blood meals from viremic mice were more infectious than artificial blood meals of comparable doses; the Cambodia strain was not transmitted by mosquitoes from Brazil after artificial blood meals, whereas 61% transmission occurred after a murine blood meal (saliva titers up to 4 log 10 infectious units/collection). Although regional origins of vector populations and virus strain influence transmission efficiency, Ae. aegypti mosquitoes appear to be competent vectors of Zika virus in several regions of the Americas.
Variation in Aedes aegypti Mosquito Competence for Zika Virus Transmission
Roundy, Christopher M.; Azar, Sasha R.; Rossi, Shannan L.; Huang, Jing H.; Leal, Grace; Yun, Ruimei; Fernandez-Salas, Ildefonso; Vitek, Christopher J.; Paploski, Igor A.D.; Kitron, Uriel; Ribeiro, Guilherme S.; Hanley, Kathryn A.
2017-01-01
To test whether Zika virus has adapted for more efficient transmission by Aedes aegypti mosquitoes, leading to recent urban outbreaks, we fed mosquitoes from Brazil, the Dominican Republic, and the United States artificial blood meals containing 1 of 3 Zika virus strains (Senegal, Cambodia, Mexico) and monitored infection, dissemination, and virus in saliva. Contrary to our hypothesis, Cambodia and Mexica strains were less infectious than the Senegal strain. Only mosquitoes from the Dominican Republic transmitted the Cambodia and Mexica strains. However, blood meals from viremic mice were more infectious than artificial blood meals of comparable doses; the Cambodia strain was not transmitted by mosquitoes from Brazil after artificial blood meals, whereas 61% transmission occurred after a murine blood meal (saliva titers up to 4 log10 infectious units/collection). Although regional origins of vector populations and virus strain influence transmission efficiency, Ae. aegypti mosquitoes appear to be competent vectors of Zika virus in several regions of the Americas. PMID:28287375
Denepitiya, L; Kleinberg, I
1984-01-01
Of the 20 strains tested, Strep. mutans Ingbritt (c), LM-7(e), QP50 -1(f) and K-1R(d/g) produced the largest decreases in pH with glucose, sucrose and starch whereas E-49(a), OMZ-61(a), FA-1(b), BHT(b), GS-5(c) and OMZ-176(d/g) produced the least. In the absence of saliva, catabolism of starch was less than catabolism of either glucose or sucrose but, with saliva present, the differences were considerably reduced. The strains varied in ability to accumulate and degrade stored polysaccharide (a means of producing a more acidic pH), but without relation to serotype. No strains showed pH-rise activity with saliva supernatant, sialin or urea but the b serotypes showed pH rise with arginine and lysylarginine . All strains showed activity from endogenous substrates. Aciduricity was determined by assessing the ability to grow on brain-heart-infusion agar adjusted to pH 5.0 to 7.0. All strains grew better at pH 7.0 than 5.0. Among the least aciduric strains were those of b serotype which being among those least able to decrease the pH with fermentable carbohydrate and the only one to raise pH with arginine and arginine peptide, suggested that this serotype might appear more often in caries-free than in caries-active plaques and in plaques showing a less acidic Stephan pH response. The acid-base and aciduric properties of the non-b serotype strains indicated that any one or more of these could be associated with caries-active plaques.
Voelker, Marsha A; Simmer-Beck, Melanie; Cole, Molly; Keeven, Erin; Tira, Daniel
2013-02-01
The purpose of this preliminary study was to examine the relationship of caries risk, salivary buffering capacity, salivary pH, salivary quality (flow, consistency) and levels of Streptococcus mutans in relation to cigarette smoking. This clinical trial consisted of 53 volunteer patients receiving care in a university based dental hygiene clinic. Participants completed a questionnaire specific to their social history in regards to tobacco use, oral health and dietary history. Measurements of unstimulated saliva were collected followed by collection of stimulated saliva samples. These samples were used to measure salivary pH, buffering capacity and Streptococcus mutans levels. The subject's smoking status was significantly associated with caries risk (p= 0.001), with 25% of the variability of caries risk attributed to smoking. The smoking status was significantly associated with buffering capacity (p=0.025), with 9% of the variability of buffering status attributed to the smoking. Associations between smoking status and salivary pH were not statistically significant. The subject's caries risk was significantly associated with buffering capacity (p= 0.001), with 25% of the variability of caries risk attributed to the buffering capacity. The subject's caries risk was significantly associated with salivary pH (p= 0.031), with 9% of the variability of caries risk attributed to the salivary pH. The Streptococcus mutans test showed no statistical significance (p>0.05) possibly due to the number and low variance in the subjects. A relationship between caries risk and smoking, buffering capacity and smoking, and stimulated salivary pH and smoking were concluded. No significance difference (p>0.05) between caries risk and salivary pH, salivary quality and smoking, S. mutans and smoking were noted from the preliminary results.
Souto, Renata; Silva-Boghossian, Carina M; Colombo, Ana Paula Vieira
2014-01-01
P. aeruginosa and Acinetobacter spp. are important pathogens associated with late nosocomial pneumonia in hospitalized and institutionalized individuals. The oral cavity may be a major source of these respiratory pathogens, particularly in the presence of poor oral hygiene and periodontal infection. This study investigated the prevalence of P. aeruginosa and Acinetobacter spp. in subgingival biofilm and saliva of subjects with periodontal disease or health. Samples were obtained from 55 periodontally healthy (PH) and 169 chronic periodontitis (CP) patients. DNA was obtained from the samples and detection of P. aeruginosa and Acinetobacter spp. was carried out by multiplex and nested PCR. P. aeruginosa and Acinetobacter spp. were detected in 40% and 45% of all samples, respectively. No significant differences in the distribution of these microorganisms between men and women, subgingival biofilm and saliva samples, patients ≤ 35 and > 35 years of age, and smokers and non-smokers were observed regardless periodontal status (p > 0.05). In contrast, the frequencies of P. aeruginosa and Acinetobacter spp. in saliva and biofilm samples were significantly greater in CP than PH patients (p < 0.01). Smokers presenting P. aeruginosa and high frequencies of supragingival plaque were more likely to present CP than PH. P. aeruginosa and Acinetobacter spp. are frequently detected in the oral microbiota of CP. Poor oral hygiene, smoking and the presence of P. aeruginosa are strongly associated with periodontitis.
Souto, Renata; Silva-Boghossian, Carina M.; Colombo, Ana Paula Vieira
2014-01-01
P. aeruginosa and Acinetobacter spp. are important pathogens associated with late nosocomial pneumonia in hospitalized and institutionalized individuals. The oral cavity may be a major source of these respiratory pathogens, particularly in the presence of poor oral hygiene and periodontal infection. This study investigated the prevalence of P. aeruginosa and Acinetobacter spp. in subgingival biofilm and saliva of subjects with periodontal disease or health. Samples were obtained from 55 periodontally healthy (PH) and 169 chronic periodontitis (CP) patients. DNA was obtained from the samples and detection of P. aeruginosa and Acinetobacter spp. was carried out by multiplex and nested PCR. P. aeruginosa and Acinetobacter spp. were detected in 40% and 45% of all samples, respectively. No significant differences in the distribution of these microorganisms between men and women, subgingival biofilm and saliva samples, patients ≤ 35 and > 35 years of age, and smokers and non-smokers were observed regardless periodontal status (p > 0.05). In contrast, the frequencies of P. aeruginosa and Acinetobacter spp. in saliva and biofilm samples were significantly greater in CP than PH patients (p < 0.01). Smokers presenting P. aeruginosa and high frequencies of supragingival plaque were more likely to present CP than PH. P. aeruginosa and Acinetobacter spp. are frequently detected in the oral microbiota of CP. Poor oral hygiene, smoking and the presence of P. aeruginosa are strongly associated with periodontitis. PMID:25242933
Lomate, Purushottam R; Bonning, Bryony C
2018-07-01
Management of the brown marmorated stink bug, Halyomorpha halys (Hemiptera: Pentatomidae), an invasive, agricultural pest in the United States, has presented significant challenges. This polyphagous insect uses both extra-oral and gut-based digestion thwarting protein- or nucleotide-based control strategies. The objective of this study was to biochemically characterize the digestive enzymes (proteases and nucleases) from the saliva, salivary gland and the gut of H. halys. Enzyme profiles for the two tissues and saliva radically differ: The pH optimum for proteases in the gut was six, with cysteine proteases predominant. In contrast, the alkaline pH optima for protease activity in the salivary gland (8-10) and saliva (7) reflected abundant serine protease and cathepsin activities. RNase enzymes were most abundant in saliva, while dsRNase and DNase activities were higher in the salivary gland and saliva compared to those in the gut. These very different enzyme profiles highlight the biphasic digestive system used by this invasive species for efficient processing of plant nutrients. Knowledge of H. halys digestive physiology will allow for counteractive measures targeting digestive enzymes or for appropriate protection of protein- or nucleotide-based management options targeting this pest. © 2018 Wiley Periodicals, Inc.
Influence of leucite content on slow crack growth of dental porcelains.
Cesar, Paulo F; Soki, Fabiana N; Yoshimura, Humberto N; Gonzaga, Carla C; Styopkin, Victor
2008-08-01
To determine the stress corrosion susceptibility coefficient, n, of seven dental porcelains (A: Ceramco I; B: Ceramco-II; C: Ceramco-III; D: d.Sign; E: Cerabien; F: Vitadur-Alpha; and G: Ultropaline) after aging in air or artificial saliva, and correlate results with leucite content (LC). Bars were fired according to manufacturers' instructions and polished before induction of cracks by a Vickers indenter (19.6N, 20s). Four specimens were stored in air/room temperature, and three in saliva/37 degrees C. Five indentations were made per specimen and crack lengths measured at the following times: approximately 0; 1; 3; 10; 30; 100; 300; 1000 and 3000 h. The stress corrosion coefficient n was calculated by linear regression analysis after plotting crack length as a function of time, considering that the slope of the curve was [2/(3n+2)]. Microstructural analysis was performed to determine LC. LC of the porcelains were 22% (A and B); 6% (C); 15% (D); 0% (E and F); and 13% (G). Except for porcelains A and D, all materials showed a decrease in their n values when stored in artificial saliva. However, the decrease was more pronounced for porcelains B, F, and G. Ranking of materials varied according to storage media (in air, porcelain G showed higher n compared to A, while in saliva both showed similar coefficients). No correlation was found between n values and LC in air or saliva. Storage media influenced the n value obtained for most of the materials. LC did not affect resistance to slow crack growth regardless of the test environment.
Salivary buffer capacity, pH, and stimulated flow rate of crack cocaine users.
Woyceichoski, Iverson Ernani Cogo; Costa, Carlos Henrique; de Araújo, Cristiano Miranda; Brancher, João Armando; Resende, Luciane Grochocki; Vieira, Iran; de Lima, Antonio Adilson Soares
2013-08-01
Crack cocaine is the freebase form of cocaine that can be smoked. The use of this drug has been considered a public health problem in many countries. The aim of this study was to assess the stimulated salivary flow rate (SSFR), pH, and the buffer capacity of saliva in crack cocaine users. Stimulated whole saliva was collected from 54 selected crack cocaine users and 40 non-users. All samples were analyzed for SSFR, pH, and buffer capacity. SSFR was analyzed by gravimetric method. The buffer capacity and pH were determined using a digital pH meter. The crack cocaine users demonstrated higher buffer capacity than the control group (P > 0.05). Salivary pH was lower in crack cocaine users (P < 0.05). Mean values of the SSFR for the experimental and control groups were 1.1 and 1.3 mL/min, respectively (P > 0.05). Crack cocaine users might exhibit a significant decrease in salivary pH, but not in salivary flow rate or buffer capacity. © 2012 Blackwell Publishing Asia Pty Ltd.
Rockenbach, Maria I; Marinho, Sandra A; Veeck, Elaine B; Lindemann, Laura; Shinkai, Rosemary S
2006-01-01
Background Studies on salivary variables and pregnancy in Latin America are scarce. This study aimed to compare salivary flow rate, pH, and concentrations of calcium, phosphate, and sIgA of unstimulated whole saliva in pregnant and non-pregnant Brazilians. Methods Cross-sectional study. Sample was composed by 22 pregnant and 22 non-pregnant women attending the Obstetrics and Gynecology Clinics, São Lucas Hospital, in Porto Alegre city, South region of Brazil. Unstimulated whole saliva was collected to determine salivary flow rate, pH, and biochemical composition. Data were analyzed by Student t test and ANCOVA (two-tailed α = 0.05). Results No difference was found for salivary flow rates and concentrations of total calcium and phosphate between pregnant and non-pregnant women (p > 0.05). Pregnant women had lower pH (6.7) than non-pregnant women (7.5) (p < 0.001), but higher sIgA level (118.9 mg/L) than the latter (90.1 mg/L) (p = 0.026). Conclusion Some of the tested variables of unstimulated whole saliva were different between pregnant and non-pregnant Brazilians in this sample. Overall, the values of the tested salivary parameters were within the range of international references of normality. PMID:17132167
Evaluation of Salivary Flow Rate, pH and Buffer in Pre, Post & Post Menopausal Women on HRT.
D R, Mahesh; G, Komali; K, Jayanthi; D, Dinesh; T V, Saikavitha; Dinesh, Preeti
2014-02-01
Climateric is considered to be a natural phase of life which by definition is the period of life starting from decline in ovarian activity until after the end of ovarian function. It is accompanied by various health consequences that include the changes in saliva too. This study was carried out to evaluate the salivary flow rate, pH, buffering capacity in pre-menopausal, post-menopausal and post-menopausal women on HRT. (1) To evaluate the salivary flow rate, pH of resting saliva and stimulated saliva and buffer capacity of stimulated saliva in pre-menopausal, post-menopausal and post-menopausal women on Hormone Replacement Therapy (HRT). (2) To compare the above salivary findings between pre-menopausal, post-menopausal and post-menopausal women on HRT. The study was carried out on 60 patients. These patients were divided into three groups of 20 patients: Group 1: Pre-menopausal women (control), Group 2: post-menopausal women (case), Group 3: post-menopausal women on HRT (case). The control group consisted of 20 women volunteers, having regular ovulatory menstrual cycles with no known systemic illness and deleterious habits and Group 2 consists of 20 post-menopausal women and Group 3 will consist of 20 post-menopausal women on HRT. After clearing the mouth by swallowing, stimulated saliva was collected after chewing paraffin for 10 mins in to a glass centrifuge tube graded in 0.1 mL increments up to 10mL.in rare cases the collection time will be reduced or extended (5-15 min), salivary flow rate will be determined as ml/min, immediately after collection, pH was determined by dipping pH test paper directly into the sample of oral fluid, salivary buffer capacity was determined by using saliva check buffer kit (GC corporation). The data obtained was statistically evaluated using chi-square test, fisher exact test ANOVA analysis. In our study we found salivary flow rate significantly lower in the post-menopausal women in comparison with the menstruating women and also there was improvement in the flow rate in individuals who were on HRT, it was also observed that salivary pH of the post-menopausal group was significantly lower than that of the control group, statistically significant difference in buffer capacity values was found between the groups however buffer capacity values were higher in the post-menopausal group than the control group. From the above study it is clear that post-menopausal women will present with oral discomfort, while HRT can improve the same. Hence our role as physicians and health care providers is to incorporate preventive dental health care in post-menopausal women and clearly inform patients about both the benefits and the limitations of HRT.
Salivary characteristics of children and its relation to oral microorganism and lip mucosa dryness.
Alamoudi, Najlaa; Farsi, Najat; Faris, Jamila; Masoud, Ibrahim; Merdad, Khaled; Meisha, Dalia
2004-01-01
The aim of this paper was to present baseline data on various saliva properties among a group of Saudi children aged 5 to 11 years and to study the relationship of these properties to some oral micro-organisms as well as to lip and oral mucosa dryness. The results showed a mean of resting and stimulated flow rate of 0.54 +/- 0.40 and 1.23 +/- 0.59 respectively and mean pH value of 7.27 +/- 0.38 and 7.5 +/- .035 respectively. Fluoride concentration was estimated to be 0.151 +/- 0.07 and 0.145 +/- 0.06 in resting and stimulated saliva respectively. Children with dry lip represented 33.9% of the sample population, whereas, those with dry mucosa represented only 0.8%. No significant sex difference was evident in all parameters. 59.1% of children showed medium buffering capacity in the resting saliva, whereas, the majority of children (73.7%) showed high stimulated buffering capacity. Children showed generally high Lactobacillus counts (Lb) in the resting and stimulated saliva (57.9% and 60.5% of children). The presence of yeast also in resting and stimulated saliva seemed high in general (40% and 53% of children had high count). However, Streptococcus mutans (S. mutans) counts showed no discriminating trend in both types of saliva. The data showed no significant association between flow rate and Lb counts in both resting and stimulated saliva although there was a trend toward higher counts associated with low flow rate. The same trend was observed in resting saliva although not significant. Similarly, low resting buffering capacity was associated with high counts of Lb among a high proportion of children (68.6% of children) although not significant. A significant reverse relation was evident between S. mutans counts and stimulated flow rate (p=0.049). The majority of children with normal level of saliva pH showed no yeast colonization (62.1%). The association was significant (p=.024). Similarly, the same association was observed in the medium and high buffering group (66.2%) (p=.040). It was concluded that salivary Lb count seems to be primarily affected by some local factors other than salivary properties, such as diet. Significant inverse relationship was found between S. mutans and stimulated salivary flow. Children in general showed high percentage of yeast reflecting the affect of poor diet among the studied population group. Buffering capacity and pH had an important role in yeast colonization.
Effect of ozone to remineralize initial enamel caries: in situ study.
Samuel, S R; Dorai, S; Khatri, S G; Patil, S T
2016-06-01
Effect of ozonated water in remineralizing artificially created initial enamel caries was investigated using laser fluorescence and polarized light microscopy in an in situ study. Teeth specimens (buccal sections) were immersed in 5-ml solution of 2 mM CaCl2, 2 mM NaH2P04, and 50 mM CH3COOH at pH of 4.55 for 5 h in an incubator at 37° to create subsurface demineralization. After which, they were randomly allocated into one of the following remineralization regimens: ozone (ozonated water 0.1 mg/l and 10 % nano-hydroxyapatite paste, Aclaim(TM)), without ozone (only 10 % nano-hydroxyapatite paste, Aclaim(TM)), and control (subjects' saliva alone). Specimens were embedded in acrylic retainers worn by orthodontic patients throughout the 21-day study duration and constantly exposed to their saliva. Laser fluorescence was recorded for all the specimens at baseline, after demineralization, and remineralization using DIAGNOdent, and the results were validated using polarized microscopic examination. The results were analyzed using repeated measures, one-way ANOVA with post hoc multiple comparisons. Reduced DIAGNOdent scores and greater depth of remineralization following application of ozonated water and nano-hydroxyapatite were found compared to those of the without ozone and control groups (P < 0.001), and the ozone-treated group exhibited maximum remineralization under the polarized light microscopy. Ozonated water can be considered an effective agent in reversing the initial enamel caries alongside with nano-hydroxyapatite compared to nano-hydroxyapatite alone and saliva. Ozone water can be used to remineralize incipient carious lesions, and it enhances the remineralizing potential of nano-hydroxyapatite thereby preventing the tooth from entering into the repetitive restorative cycle.
Kinetics of salivary pH after acidic beverage intake by patients undergoing orthodontic treatment.
Turssi, Cecilia P; Silva, Carolina S; Bridi, Enrico C; Amaral, Flavia Lb; Franca, Fabiana Mg; Basting, Roberta T
2015-01-01
The saliva of patients undergoing orthodontic treatment with fixed appliances can potentially present a delay in the diluting, clearing, and buffering of dietary acids due to an increased number of retention areas. The aim of this clinical trial was to compare salivary pH kinetics of patients with and without orthodontic treatment, following the intake of an acidic beverage. Twenty participants undergoing orthodontic treatment and 20 control counterparts had their saliva assessed for flow rate, pH, and buffering capacity. There was no significant difference between salivary parameters in participants with or without an orthodontic appliance. Salivary pH recovery following acidic beverage intake was slower in the orthodontic subjects compared to controls. Patients with fixed orthodontic appliances, therefore, seem to be at higher risk of dental erosion, suggesting that dietary advice and preventive care need to be implemented during orthodontic treatment.
Effect of a single application of TiF(4) and NaF varnishes and solutions on dentin erosion in vitro.
Magalhães, Ana Carolina; Levy, Flávia Mauad; Rios, Daniela; Buzalaf, Marília Afonso Rabelo
2010-02-01
This in vitro study aimed to analyse the effect of a single application of TiF(4) and NaF varnishes and solutions to protect against dentin erosion. Bovine root dentin samples were pre-treated with NaF-Duraphat varnish (2.26%F, pH 4.5), NaF/CaF(2)-Duofluorid varnish (5.63%F, pH 8.0), NaF-experimental varnish (2.45%F, pH 4.5), TiF(4)-experimental varnish (2.45%F, pH 1.2), NaF solution (2.26%F, pH 4.5), TiF(4) solution (2.45%F, pH 1.2) and placebo varnish (pH 5.0, no-F varnish control). Controls remained untreated. Ten samples in each group were then subjected to an erosive demineralisation (Sprite Zero, 4x 90s/day) and remineralisation (artificial saliva, between the erosive cycles) cycling for 5 days. Dentin loss was measured profilometrically after pre-treatment and after 1, 3 and 5 days of de-remineralisation cycling. The data were statistically analysed by two-way ANOVA and Bonferroni's post hoc test (p<0.05). After pre-treatment, TiF(4) solution significantly induced surface loss (1.08+/-0.53 microm). Only Duraphat reduced the dentin loss overtime, but it did not significantly differ from placebo varnish (at 3rd and 5th days) and TiF(4) varnish (at 3rd day). Duraphat varnish seems to be the best option to partially reduce dentin erosion. However, the maintenance of the effects of this treatment after successive erosive challenges is limited. Copyright 2009 Elsevier Ltd. All rights reserved.
Effect of load deflection on corrosion behavior of NiTi wire.
Liu, I H; Lee, T M; Chang, C Y; Liu, C K
2007-06-01
For dental orthodontic applications, NiTi wires are used under bending conditions in the oral environment for a long period. The purpose of this study was to investigate the effect of bending stress on the corrosion of NiTi wires using potentiodynamic and potentiostatic tests in artificial saliva. The results indicated that bending stress induces a higher corrosion rate of NiTi wires in passive regions. It is suggested that the passive oxide film of specimens would be damaged under bending conditions. Auger electron spectroscopic analysis showed a lower thickness of passive films on stressed NiTi wires compared with unstressed specimens in the passive region. By scanning electron microscopy, localized corrosion was observed on stressed Sentalloy specimens after a potentiodynamic test at pH 2. In conclusion, this study indicated that bending stress changed the corrosion properties and surface characteristics of NiTi wires in a simulated intra-oral environment.
Rojas de Morales, Thais; Navas, Rita; Viera, Ninoska; Alvarez, Carmen Julia; Chaparro, Neira; Griman, Dariana
2007-10-01
To analyze the behavior of pH and sodium bicarbonate (NAHCO3) in the saliva of patients with leukemia during the administration protocol for Methotrexate (Mtx). A controlled clinical essay was carried out on 23 patients between 4 and 18 years of age with high-risk Acute Lymphoblastic Leukemia. Sampling was carried out at To: basal condition; T1: 12 hours after intravenous administration of sodium bicarbonate, before administering Mtx and T2: 3 hours after administering Mtx, the time of maximum concentration. Chiron-Diagnostic 378 equipment was used to determine pH and sodium bicarbonate. The data was interpreted using Analysis of Variance at the 5% significance level. The highest values of sodium bicarbonate were observed at T2, with salivary pH levels remaining within neutrality ranges, diminishing slightly in T1. CONCLUSION. In this study, the dose of sodium bicarbonate considered in the administration protocol of 3 g /m2 Mtx, kept sodium bicarbonate levels in saliva at normal levels and pH neutral.
Mobarak, E H
2011-01-01
To evaluate the influence of 2% and 5% chlorhexidine (CHX) pretreatment on bond durability of a self-etching adhesive to normal (ND) and caries-affected (AD) dentin after 2-years of aging in artificial saliva and under simulated intrapulpal pressure (IPP). One hundred twenty freshly extracted carious teeth were ground to expose ND and AD. Specimens were distributed into three equal groups (n=40) according to whether the dentin substrates were pretreated with 2% or 5% CHX or with water (control). Clearfil SE Bond (Kuraray) was applied to both substrates and composite cylinders (0.9 mm diameter and 0.7 mm height) were formed. Pretreatment and bonding were done while the specimens were subjected to 15 mm Hg IPP. After curing, specimens were aged in artificial saliva at 37°C and under IPP at 20 mm Hg until being tested after 24 hours or 2 years (n=20/group). Microshear bond strength was evaluated. Failure modes were determined using a scanning electron microscope (SEM) at 400× magnification. Data were statistically analyzed using three-way analysis of variance (ANOVA); one-way ANOVA tests, and t-test (p<0.05). Additional specimens (n=5/group) were prepared to evaluate interfacial silver precipitation. For the 24-hour groups, there were no significant differences among the ND groups and AD groups. For ND aged specimens, the 5% CHX group had the highest value followed by the 2% CHX and control groups, although the difference was statistically insignificant. For AD aged specimens, the 5% CHX group revealed statistically higher bond values compared to the 2% CHX and control groups. Fracture modes were predominately adhesive and mixed. Different interfacial silver depositions were recorded. Two percent or 5% CHX pretreatment has no adverse effect on the 24-hour bonding to ND and AD. Five percent CHX was able to diminish the loss in bonding to AD after 2years of aging in artificial saliva and under simulated IPP.
Channa, Naseem Aslam; Kalhoro, Dost Muhammad; Jahangir, Taj Muhammad
2018-01-01
The present study was designed to explore the easy and fast method diagnosis of tobacco products in saliva of tobacco users (TU) by FTIR. Sixty four male tobacco users (TU) with mean age range 15.3 to 30.7 years were randomly selected for collection of saliva samples before and after tobacco use (smoking, chewing and dipping tobacco). Twenty were the smoking tobacco users (STU), 24 were chewing tobacco users (CTU) and 20 were dipping tobacco users (DTU). CTU were the users of Mainpuri (n=10) and users of PEN, FIT, 2100 (n=14). Forty eight saliva samples of age and gender matched healthy individuals with negative personal or family history of any addiction were also collected for comparison which served as controls. All were analyzed for their salivary flow rate, salivary pH and salivary diagnostic bands by FTIR. Significantly increased SFR (p<0.05) and salivary pH were found in after chewing tobacco as compared to before its chewing. The comparison between after tobacco use and controls we found decreased SFR and salivary pH for STU. Significant decreased SFR and increased salivary pH were found before or after use of dipping tobacco as compared to controls. Sharp bands at 735-745 cm-1 were found and may be used as salivary diagnostic bands for STU, 945-949 cm-1 for DTU and 900-915 cm-1 for CTU as well as DTU. In conclusion, the salivary diagnostic bands were found at 735-745 cm -1 , 900-915 cm -1 and 945-949 cm -1 for TU by easy and fast method using FTIR.
Salivary pH, calcium, phosphorus and selected enzymes in healthy dogs: a pilot study.
Iacopetti, Ilaria; Perazzi, Anna; Badon, Tamara; Bedin, Silvia; Contiero, Barbara; Ricci, Rebecca
2017-11-10
Saliva in dogs, as in humans, is a complex fluid secreted by different salivary glands in the oral cavity to protect the oral mucosa and teeth. The use of saliva as a substitute for blood in diagnosing and prognosticating disease in humans is widely accepted. Salivary biochemistry has also been used as a marker for periodontal disease in humans. No studies have as yet investigated the relation between salivary biochemistry and periodontal disease in dogs, however; neither has the salivary composition of healthy dogs with no oral disease been assessed. The purpose of this study was to obtain an overview on pH distribution and a set of salivary biochemical analytes (calcium, phosphorus, lactate dehydrogenase, lysozyme and amylase) commonly related to oral health in humans in a subset population of healthy young dogs with no periodontal disease or previous oral disease. Data were analyzed to gather salivary reference ranges for pH and each parameter and to assess a possible correlation between salivary and serum analytes. Twenty-nine adult client-owned dogs were recruited for the study. Lactate dehydrogenase and lysozyme showed higher concentrations in saliva than in serum, whereas amylase showed the contrary. Salivary biochemistry values did not differ between males and females or between non-neutered and neutered individuals. No significant correlations between salivary and serum calcium, phosphorus, lactate dehydrogenase, amylase and lysozyme were identified in this study. Data allowed intervals for the salivary pH and other analytes investigated to be obtained from healthy dogs with healthy oral conditions. These preliminary data can contribute to enlarge our understanding of the functional role of saliva and its relation to oral health in dogs.
Davis, Bennet; Davis, Kathy; Bigelow, Sandy; Healey, Patricia
To determine if the use of toothpicks infused with flavoring and flavoring plus the food additive spilanthol (Xerosticks™) improve saliva flow in people with opioid-induced dry mouth. Time series, nonrandomized, double-blind within-subject design. Private practice/academic multidisciplinary pain and palliative care clinic. Ten subjects with opioid-induced dry mouth were recruited, and all finished the study. Salivary flow and pH were measured consecutively at baseline, following use of a mango-flavored toothpick, and again after use of a mango-flavored toothpick infused with spilanthol. Salivary flow rates and saliva pH were compared between flavored and baseline, between flavored + spilanthol and baseline, and between the flavored and flavored + spilanthol. Mouthfeel of each toothpick was assessed using the Bluestone Mouthfeel Questionnaire. The primary measure was salivary flow, and the secondary measures were salivary pH and mouthfeel. Saliva flow increased 440 percent over baseline with use of a flavored toothpick and 628 percent over baseline with similarly flavored toothpicks infused with spilanthol, and these differences are significant (p = 0.00002). Saliva pH increased with both toothpicks (p = 0.04). The addition of spilanthol produced a greater increase in salivary flow (p = 0.05) compared to control toothpicks with flavoring alone. Furthermore, addition of spilanthol improved the "mouthfeel" of the toothpick (p = 0.00001). Toothpicks infused with either flavoring or flavoring plus spilanthol are likely to be an effective remedy for opioid-induced dry mouth. Addition of spilanthol may improve effectiveness over flavoring alone and may be better ac-cepted because spilanthol appears to improve mouthfeel.
Dibdin, G H; Dawes, C
1998-01-01
Urea diffusing from saliva into dental plaque is converted to ammonia and carbon dioxide by bacterial ureases. The influence of normal salivary urea levels on the pH of fasted plaque and on the depth and duration of a Stephan curve is uncertain. A numerical model which simulates a cariogenic challenge (a 10% sucrose rinse alone or one followed by use of chewing-gum with or without sugar) was modified to include salivary urea levels from 0 to 30 mmol/l. It incorporated: site-dependent exchange between bulk saliva and plaque surfaces via a salivary film; sugar and urea diffusion into plaque; pH-dependent rates of acid formation and urea breakdown; diffusion and dissociation of end-products and other buffers (acetate, lactate, phosphate, ammonia and carbonate); diffusion of protons and other ions; equilibration with fixed and mobile buffers; and charge-coupling between ionic flows. The Km (2.12 mmol/l) and Vmax (0.11 micromol urea/min/mg dry weight) values for urease activity and the pH dependence of Vmax were taken from the literature. From the results, it is predicted that urea concentrations normally present in saliva (3-5 mmol/l) will increase the pH at the base of a 0.5-mm-thick fasted plaque by up to 1 pH unit, and raise the pH minimum after a sucrose rinse or sugar-containing chewing-gum by at least half a pH unit. The results suggest that plaque cariogenicity may be inversely related to salivary urea concentrations, not only when the latter are elevated because of disease, but even when they are in the normal range.
Impact of a modified carbonated beverage on human dental plaque and salivary pH: an in vivo study.
Sardana, V; Balappanavar, A Y; Patil, G B; Kulkarni, N; Sagari, S G; Gupta, K D
2012-01-01
To assess the plaque and salivary pH changes at different time intervals in vivo after consumption of a carbonated beverage modified with sodium fluoride and calcium phosphate. Twenty-four subjects aged 18-25 years were recruited and randomly assigned to three groups (group A, original drink Sprite; group B, Sprite with sodium fluoride; group C, Sprite with calcium phosphate). Collection of pooled plaque and unstimulated saliva was done before and after the drinks were consumed by the subjects at 5-, 10-, 20- and 30-minute intervals. The pH rise was higher with group C for plaque and group B for saliva. Modification of the test carbonated beverage with calcium phosphate and fluoride may exert some protective potential, especially in high caries risk candidates.
Mehta, R; Nandlal, B; Prashanth, S
2013-01-01
World-wide, the contribution of dental caries to the burden of oral diseases is about 10 times higher than that of periodontal disease, the other common oral condition. Owing to its globally high prevalence, dental caries is a "pandemic" disease characterized by a high percentage of untreated carious cavities causing pain, discomfort and functional limitations. Untreated carious cavities; furthermore, have a significant impact on the general health of children and on the social and economic well-being of communities. A surgical approach to the elimination of carious lesion was developed a century ago; this approach was necessary at that time, because there was no valid alternative. The focus in caries has recently shifted to the development of methodologies for the detection of the early stages of caries lesions and the non-invasive treatment of these lesions. The non-invasive treatment of early lesions by remineralization has the potential to be a major advance in the clinical management of the disease. Remineralization of white-spot lesions may be possible with a variety of currently available agents containing fluoride, bioavailable calcium and phosphate and phosphate. This concept bridges the traditional gap between prevention and surgical procedures, which is just what dentistry needs today. The aim of this in vitro study was to evaluate and to compare the remineralization potential of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and casein phosphopeptide-amorphous calcium fluoride phosphate (CPP-ACFP) on artificial white spot enamel lesions using the quantitative light fluorescence (QLF). A total of 45 caries-free extracted maxillary first premolars were embedded in acrylic resin. The samples were randomly divided into three groups namely control group, CPP-ACP group and CPP-ACFP group with 15 samples in each group. The samples of each group were subjected to demineralization process for a period of 96 h. The samples were then mounted in the artificial mouth model and subjected to remineralization and pH cycling for a period of 21 days. QLF readings were recorded at the end of demineralization (1st, 7th, 14th and 21st day) and were statistically analyzed. As compared with artificial saliva both CPP-ACP and CPP-ACFP produced significant amount of remineralization of the artificial enamel white spot lesion (P < 0.001), however when the remineralizing effect of CPP-ACP was compared with the remineralizing effect of CPP-ACFP there was no significant difference. Significant amount of remineralization was produced by CPP-ACP and CPP-ACFP only after the 7th day. After the 14th day, the remineralization produced by both CPP-ACP and CPP-ACFP as compared to artificial saliva was non-significant.
Shekhar, Abhishek; Das, Samiran; Bhattacharyya, Jayanta; Goel, Preeti; Majumdar, Sayan; Ghosh, Soumitra
2018-01-01
This study aims to find the effect of change in different salivary factors before and after complete denture insertion and to measure the maxillary denture retention in different arch forms. Thirty completely edentulous individuals (10 each of square, tapered, and ovoid arch form of maxilla) belonging to the age group of 40-70 years were selected. Salivary factors (flow, density, pH, viscosity, and total protein) were evaluated before and after denture insertion. Retention of maxillary denture was measured in all the different arch forms. Student's independent sample's t -test was applied. The correlation was analyzed by Pearson's correlation analysis. While mean flow rate and pH of saliva increased, mean viscosity, total protein, and density of saliva decreased after maxillary complete denture insertion. A positive correlation was found between retention and total maxillary basal surface area. Retention value was found to be greatest in square type and least in tapered type. Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.
The tribocorrosion behaviour of NiTi alloy
NASA Astrophysics Data System (ADS)
Kosec, Tadeja; Močnik, Petra; Legat, Andraž
2014-01-01
In biomedical applications, NiTi alloys are used mainly because of their favourable shape memory and superelastic properties. However, in many applications the tribocorrosion properties of these alloys can be of critical concern. For this reason the electrochemical and tribocorrosion properties of superelastic NiTi sheet and orthodontic archwire were studied, taking into account their microstructures and the effect of different surface finishes. In the case of the electrochemical tests, samples were tested in artificial saliva, whereas in the tribocorrosion tests the experiments were performed in ambient air, distilled water, and artificial saliva, the latter as a corrosive medium. In these tests, the total wear rate of the alloy samples was determined, together with the corresponding chemical and tribological contributions. It was confirmed that the microstructure of the investigated alloys had a significant effect on the measured electrochemical and tribocorrosion properties.
Geng, Li; Qiao, Guang-yan; Gu, Kai-ka
2016-04-01
To investigate the effect of fluoride on electrochemical corrosion of the dental pure titanium before and after adhesion of Streptococcus mutans. The dental pure titanium specimens were tested by electrochemical measurement system including electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization curve (PD) methods in artificial saliva with 0 g/L and 1.0 g/L sodium fluoride before and after dipped into culture medium with Streptococcus mutans for 24 h. The corrosion parameters, including the polarization resistance (R(ct)), corrosion potential (E(corr)), pitting breakdown potential (E(b)), and the difference between E(corr) and E(b) representing the "pseudo-passivation" (ΔE) obtained from the electrochemical tests were used to evaluate the corrosion resistance of dental pure titanium. The data were statistically analyzed by 2×2 factorial statistical analysis to examine the effect of sodium fluoride and adhesion of Streptococcus mutans using SPSS 12.0 software package. The results showed that the corrosion parameters including R(ct), Ecorr, E(b), and ΔE of pure titanium had significant difference between before and after adhesion of Streptococcus mutans in the same solution(P<0.05), and in artificial saliva with 0 g/L and 1.0 g/L sodium fluoride(P<0.05). The dental pure titanium was prone to corrosion in artificial saliva with sodium fluoride. The corrosion resistance of pure titanium decreased distinctly after immersed in culture medium with Streptococcus mutans.
NASA Astrophysics Data System (ADS)
Arain, Sadaf Sadia; Kazi, Tasneem Gul; Arain, Asma Jabeen; Afridi, Hassan Imran; Baig, Jameel Ahmed; Brahman, Kapil Dev; Naeemullah; Arain, Salma Aslam
2015-03-01
A new approach was developed for the preconcentration of cadmium (Cd) and nickel (Ni) in artificial saliva extract of dry snuff (brown and black) products using temperature-controlled ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (TIL-UDLLμE) followed by electrothermal atomic absorption spectrometry (ETAAS). The Cd and Ni were complexed with ammonium pyrrolidinedithiocarbamate (APDC), extracted in ionic liquid drops, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6]. The multivariate strategy was applied to estimate the optimum values of experimental variables influence the % recovery of analytes by TIL-UDLLμE method. At optimum experimental conditions, the limit of detection (3s) were 0.05 and 0.14 μg L-1 while relative standard deviations (% RSD) were 3.97 and 3.55 for Cd and Ni respectively. After extraction, the enhancement factors (EF) were 87 and 79 for Cd and Ni, respectively. The RSD for six replicates of 10 μg L-1 Cd and Ni were 3.97% and 3.55% respectively. To validate the proposed method, certified reference material (CRM) of Virginia tobacco leaves was analyzed, and the determined values of Cd and Ni were in good agreement with the certified values. The concentration of Cd and Ni in artificial saliva extracts corresponds to 39-52% and 21-32%, respectively, of the total contents of both elements in dry brown and black snuff products.
Effect of Mucoprotein on the Bond Strength of Resin Composite to Human Dentin
Pinzon, Lilliam M; Powers, John M; O'Keefe, Kathy; Dusevish, Vladimir; Spencer, Paulette; Marshall, Grayson W
2010-01-01
The purpose of this study was to test the bond strength and analyze the morphology of the dentin-adhesive interface of two etch and rinse and two self-etch adhesive systems with two kinds of artificial saliva (with and without 450 mg/L mucin) contamination under different conditions of decontaminating the interface. Bonded specimens were sectioned perpendicularly to the bonded surface in 1-mm thick slabs. These 1-mm thick slabs were remounted in acrylic blocks and sectioned in sticks perpendicular to the bonding interfaces with a 1-mm2 area. Nine specimens from each condition were tested after 24 hours on a testing machine (Instron) at a speed of 0.5 mm/min for a total of 360 specimens. Means and standard deviations of bond strength (MPa) were calculated. ANOVA showed significant differences as well as Fisher's PLSD intervals (p<0.05). Different groups results ranges: Control group 34-60 MPa, saliva without mucin 0-52 MPa, and saliva with mucin 0-57 MPa. Failure sites were mixed, adhesive failure was common for the low bond strength results. P&BNT with ideal conditions and following the manufacturer's instructions (control) had the highest bond strengths and the dentin-adhesive interface exhibited an ideal morphology of a etch and rinse system. SEM gave complementary visual evidence of the effect in the dentin/adhesive interface structure with some contaminated conditions compared to their respective control groups. This in-vitro artificial saliva model with and without mucin showed that an organic component of saliva could increase or decrease the bond strength depending on the specific bonding agent and decontamination procedure. PMID:14505182
Evaluation of the erosive potential of soft drinks.
de Carvalho Sales-Peres, Sílvia Helena; Magalhães, Ana Carolina; de Andrade Moreira Machado, Maria Aparecida; Buzalaf, Marília Afonso Rabelo
2007-01-01
This in vitro study evaluated the capability of different soft drinks (Coca-Cola(R)-C, Coca-Cola Light(R)-CL, Guaraná(R)-G, Pepsi Twist(R)-P and Sprite Light(R)-SL) to erode dental enamel, relating the percentage of superficial microhardness change (%SMHC) to concentrations of fluoride and phosphate, buffering capacity and pH of these drinks. The soft drinks were evaluated in respect to concentration of phosphate and fluoride spectrophotometrically using Fiske, Subarrow method and by specific electrode (Orion 9609), respectively. The pH and the buffering capacity were determined by glass electrode and by estimating of the volume of NaOH necessary to change the pH of the drink in one unit, respectively. One hundred specimens of bovine enamel were randomly assigned to 5 groups of 20 each. They were exposed to 4 cycles of demineralisation in the beverage and remineralisation in artificial saliva. The softening of enamel was evaluated by %SMHC. The mean %SMHC was: C=77.27%, CL= 72.45%, SL=78.43%, G=66.65% and P=67.95%. Comparing the %SMHC promoted by 5 soft drinks, SL = C > CL > P = G (P<.05). There was not significant correlation between %SMHC and the other variables tested for the five drinks (P>.05). The five soft drinks caused surface softening of enamel (erosion). In respect to the chemical variables tested, despite not statistically significant, the pH seems to have more influence on the erosive potential of these drinks. (Eur J Dent 2007;1:10-13).
Phage survival: the biodegradability of M13 phage display library in vitro.
Tóthová, L'ubomíra; Bábíčková, Janka; Celec, Peter
2012-01-01
Administration of bacteriophages is used for phage therapy modulation of gut microbiome or for in vivo phage display. The aim of the study was to analyze the survival of M13 phage in different body fluids and tissues in vitro. The survival of M13 phage was measured in vitro in human blood, saliva, urine, artificial gastric juice (AGJ), and mouse homogenates of stomach, jejunum, and colon after defined time points (5, 15, or 45 Min). The plates were inspected after overnight incubation and the plaques were counted. No phage was recovered after 5 Min of incubation with AGJ. In urine, the phage survival was decreased by 44% after 5 Min of incubation (P = 0.004). In saliva, the recovered titer was decreased by 33% and 88% (P < 0.05) after 15 and 45 Min, respectively. Phage coincubation with jejunum homogenate led to significant decrease of phage titer by 72% (P < 0.01) after 15 Min and by 99% (P < 0.001) after 45 Min. Decreased survival of M13 phage depending on time of incubation was proved under several in vitro conditions, with low pH in the AGJ having the most detrimental effect on phage survival. Phage pharmacokinetics described in vitro might have applications for the use of bacteriophages in vivo. © 2012 International Union of Biochemistry and Molecular Biology, Inc.
Authentication of forensic DNA samples.
Frumkin, Dan; Wasserstrom, Adam; Davidson, Ariane; Grafit, Arnon
2010-02-01
Over the past twenty years, DNA analysis has revolutionized forensic science, and has become a dominant tool in law enforcement. Today, DNA evidence is key to the conviction or exoneration of suspects of various types of crime, from theft to rape and murder. However, the disturbing possibility that DNA evidence can be faked has been overlooked. It turns out that standard molecular biology techniques such as PCR, molecular cloning, and recently developed whole genome amplification (WGA), enable anyone with basic equipment and know-how to produce practically unlimited amounts of in vitro synthesized (artificial) DNA with any desired genetic profile. This artificial DNA can then be applied to surfaces of objects or incorporated into genuine human tissues and planted in crime scenes. Here we show that the current forensic procedure fails to distinguish between such samples of blood, saliva, and touched surfaces with artificial DNA, and corresponding samples with in vivo generated (natural) DNA. Furthermore, genotyping of both artificial and natural samples with Profiler Plus((R)) yielded full profiles with no anomalies. In order to effectively deal with this problem, we developed an authentication assay, which distinguishes between natural and artificial DNA based on methylation analysis of a set of genomic loci: in natural DNA, some loci are methylated and others are unmethylated, while in artificial DNA all loci are unmethylated. The assay was tested on natural and artificial samples of blood, saliva, and touched surfaces, with complete success. Adopting an authentication assay for casework samples as part of the forensic procedure is necessary for maintaining the high credibility of DNA evidence in the judiciary system.
Protein Buffering in Model Systems and in Whole Human Saliva
Lamanda, Andreas; Cheaib, Zeinab; Turgut, Melek Dilek; Lussi, Adrian
2007-01-01
The aim of this study was to quantify the buffer attributes (value, power, range and optimum) of two model systems for whole human resting saliva, the purified proteins from whole human resting saliva and single proteins. Two model systems, the first containing amyloglucosidase and lysozyme, and the second containing amyloglucosidase and α-amylase, were shown to provide, in combination with hydrogencarbonate and di-hydrogenphosphate, almost identical buffer attributes as whole human resting saliva. It was further demonstrated that changes in the protein concentration as small as 0.1% may change the buffer value of a buffer solution up to 15 times. Additionally, it was shown that there was a protein concentration change in the same range (0.16%) between saliva samples collected at the time periods of 13:00 and others collected at 9:00 am and 17:00. The mode of the protein expression changed between these samples corresponded to the change in basic buffer power and the change of the buffer value at pH 6.7. Finally, SDS Page and Ruthenium II tris (bathophenantroline disulfonate) staining unveiled a constant protein expression in all samples except for one 50 kDa protein band. As the change in the expression pattern of that 50 kDa protein band corresponded to the change in basic buffer power and the buffer value at pH 6.7, it was reasonable to conclude that this 50 kDa protein band may contain the protein(s) belonging to the protein buffer system of human saliva. PMID:17327922
Gonçalves, Tatiana Siqueira; de Menezes, Luciane Macedo; Ribeiro, Luciele Gonzaga; Lindholz, Catieli Gobetti; Medina-Silva, Renata
2014-01-01
The aim of this study was to evaluate the cytotoxicity induced by orthodontic bands through survival tests on Saccharomyces cerevisiae, a microorganism that presents several genetic and biochemical characteristics similar to human cells. Three groups of bands were evaluated: silver soldered (SSB), laser soldered (LSB), and bands without any solder (WSB). Yeast cells were directly exposed to the bands and indirectly, when a previous elution of the metals in artificial saliva was performed. The negative control was composed of yeast cells or artificial saliva not exposed to any kind of metal. In the direct exposure experiments, all tested groups of bands induced a slight reduction in yeast viability compared to the control. This effect was more intense for the SSB, although not statistically significant. For the indirect exposure experiments, the SSB induced a statistically significant decrease in cell viability compared to the LSB. There were no significant differences between the survival rates of the negative control and the LSB group in both direct and saliva tests. SSBs were cytotoxic, whilst LSBs were not, confirming that laser soldering may be a more biocompatible alternative for use in connecting wires to orthodontic appliances. PMID:24511527
A nocturnal decline of salivary pH associated with airway hyperresponsiveness in asthma.
Watanabe, Masanari; Sano, Hiroyuki; Tomita, Katsuyuki; Yamasaki, Akira; Kurai, Jun; Hasegawa, Yasuyuki; Igishi, Tadashi; Okazaki, Ryota; Tohda, Yuji; Burioka, Naoto; Shimizu, Eiji
2010-08-01
Salivary pH is associated with esophageal acid reflux and neutralization of esophageal acid. In this study, we assessed the association between nocturnal decline of salivary pH and airway hyperresponsiveness. Salivary pH was serially assessed in 9 patients with mild asthma (7 men and 2 women; mean age 33.3 years; mean %predicted FEV(1.0) 89.4%) and 10 healthy volunteers (6 men and 4 women; mean age 31.2 years) using a pH indicator tape. The buffering capacity of saliva was defined as the median effective dose (ED(50)) for acidification of saliva with 0.01 N HCl, and airway responsiveness was defined as the dose of methacholine producing a 35% fall in Grs (PD(35)-Grs). There was a significant correlation between the values obtained from the pH indicator tape and those obtained from the electrometric pH meter. Using the indicator tape for sequential monitoring, we observed a nocturnal fall (ΔpH) in salivary pH in all subjects. A significant correlation was found between airway hyperresponsiveness (PD(35)-Grs) and either ΔpH or ED(50) in mildly asthmatic patients. Vagal reflux dysfunction might contribute to nocturnal salivary pH as well as to airway hyperresponsiveness in mild asthmatics.
Sim, Cpc; Soong, Y L; Pang, Epp; Lim, C; Walker, G D; Manton, D J; Reynolds, E C; Wee, Jts
2018-06-01
To evaluate changes in xerostomia status, salivary characteristics and gland volumes 2 years following radiotherapy in nasopharyngeal carcinoma patients. Xerostomia scores, salivary flow rates, pH and buffering capacity were measured at pre-radiotherapy, mid-radiotherapy, 2 weeks, 3 months and 2 years post-radiotherapy. Salivary gland volumes and their correlation with radiation dose were also assessed. Mean radiation dose to oral cavity, parotid and submandibular glands (SMG) was 44.5, 65.0 and 38.6 Gy respectively. Parotid and SMG volumes decreased 33% at 3 months post-radiotherapy; volumes at 2 years post-radiotherapy were 84% and 51% of pre-radiotherapy levels, respectively. Correlations were observed between parotid gland volume per cent reduction and its radiation dose and between resting salivary flow rate reduction and post-radiotherapy/pre-radiotherapy SMG volume ratio. Salivary flow rates and resting saliva pH remained significantly low at 2 years post-radiotherapy (both flow rates, P = 0.001; resting saliva pH, P = 0.005). Similarly, xerostomia scores remained significantly higher compared with pre-radiotherapy levels. Submandibular gland volumetric shrinkage persisted 2 years after radiotherapy. Xerostomia scores remained significantly higher, and salivary flow rates and resting saliva pH remained significantly lower, suggesting that study participants were still at risk for hyposalivation-related oral diseases. © 2018 Australian Dental Association.
Evaluation of Salivary Flow Rate, pH and Buffer in Pre, Post & Post Menopausal Women on HRT
D.R., Mahesh; G., Komali; K., Jayanthi; D., Dinesh; T.V., Saikavitha; Dinesh, Preeti
2014-01-01
Background: Climateric is considered to be a natural phase of life which by definition is the period of life starting from decline in ovarian activity until after the end of ovarian function. It is accompanied by various health consequences that include the changes in saliva too. This study was carried out to evaluate the salivary flow rate, pH, buffering capacity in pre-menopausal, post-menopausal and post-menopausal women on HRT. Aims and objectives: (1) To evaluate the salivary flow rate, pH of resting saliva and stimulated saliva and buffer capacity of stimulated saliva in pre-menopausal, post-menopausal and post-menopausal women on Hormone Replacement Therapy (HRT). (2) To compare the above salivary findings between pre-menopausal, post-menopausal and post-menopausal women on HRT. Materials and Methods: The study was carried out on 60 patients. These patients were divided into three groups of 20 patients: Group 1: Pre-menopausal women (control), Group 2: post-menopausal women (case), Group 3: post-menopausal women on HRT (case). The control group consisted of 20 women volunteers, having regular ovulatory menstrual cycles with no known systemic illness and deleterious habits and Group 2 consists of 20 post-menopausal women and Group 3 will consist of 20 post-menopausal women on HRT. After clearing the mouth by swallowing, stimulated saliva was collected after chewing paraffin for 10 mins in to a glass centrifuge tube graded in 0.1 mL increments up to 10mL.in rare cases the collection time will be reduced or extended (5-15 min), salivary flow rate will be determined as ml/min, immediately after collection, pH was determined by dipping pH test paper directly into the sample of oral fluid, salivary buffer capacity was determined by using saliva check buffer kit (GC corporation). The data obtained was statistically evaluated using chi-square test, fisher exact test ANOVA analysis. Results: In our study we found salivary flow rate significantly lower in the post-menopausal women in comparison with the menstruating women and also there was improvement in the flow rate in individuals who were on HRT, it was also observed that salivary pH of the post-menopausal group was significantly lower than that of the control group, statistically significant difference in buffer capacity values was found between the groups however buffer capacity values were higher in the post-menopausal group than the control group. Conclusion: From the above study it is clear that post-menopausal women will present with oral discomfort, while HRT can improve the same. Hence our role as physicians and health care providers is to incorporate preventive dental health care in post-menopausal women and clearly inform patients about both the benefits and the limitations of HRT. PMID:24701542
Islas-Granillo, H; Borges-Yañez, SA; Medina-Solís, CE; Galan-Vidal, CA; Navarrete-Hernández, JJ; Escoffié-Ramirez, M; Maupomé, G
2014-01-01
ABSTRACT Objective: To compare a limited array of chewing-stimulated saliva features (salivary flow, pH and buffer capacity) in a sample of elderly Mexicans with clinical, sociodemographic and socio-economic variables. Subjects and Methods: A cross-sectional study was carried out in 139 adults, 60 years old and older, from two retirement homes and a senior day care centre in the city of Pachuca, Mexico. Socio-demographic, socio-economic and behavioural variables were collected through a questionnaire. A trained and standardized examiner obtained the oral clinical variables. Chewing-stimulated saliva (paraffin method) was collected and the salivary flow rate, pH and buffer capacity were measured. The analysis was performed using non-parametric tests in Stata 9.0. Results: Mean age was 79.1 ± 9.8 years. Most of the subjects included were women (69.1%). Mean chewing-stimulated salivary flow was 0.75 ± 0.80 mL/minute, and the pH and buffer capacity were 7.88 ± 0.83 and 4.20 ± 1.24, respectively. Mean chewing-stimulated salivary flow varied (p < 0.05) across type of retirement home, tooth brushing frequency, number of missing teeth and use of dental prostheses. pH varied across the type of retirement home (p < 0.05) and marginally by age (p = 0.087); buffer capacity (p < 0.05) varied across type of retirement home, tobacco consumption and the number of missing teeth. Conclusions: These exploratory data add to the body of knowledge with regard to chewing-stimulated salivary features (salivary flow rate, pH and buffer capacity) and outline the variability of those features across selected sociodemographic, socio-economic and behavioural variables in a group of Mexican elders. PMID:25867562
Vantipalli, Usha Kiran; Avula, Sai Sankar Jogendra; Enuganti, Sridevi; Bandi, Sujatha; Kakarla, Pranitha; Kuravadi, Raja Vardhan
2017-01-01
Adequate salivary flow is an important requisite in the maintenance of oral health. Salivary flow increases in response to both gustatory (taste) and mechanical (chewing) stimuli. Hence, the aim of the present study was to know the efficacy of commercially available chewing gums (sugar free and sugared) on salivary flow rate (SFR) and pH in caries-active and caries-free children. One hundred school children aged between 10 and 12 years were divided into two groups on the basis of their caries status into caries free and caries active. Unstimulated saliva was collected before start of the study. Both groups were subjected to three commercially available chewing gums (2 sugar free, 1 sugared) on consecutive days, and saliva was collected at intervals of 2 min (T2), 10 min (T10), and 30 min (T30). The pH and flow rate of saliva samples were measured before and specified time intervals after gum chewing. In both the groups, gum chewing increased the SFR, significantly at T2, and gradually declined at T30 which was significantly higher than baseline values. The pH raised significantly at T2 and gradually declined at T30 which was significantly higher than baseline values with sugar-free gums, but with sugared gums, the pH raised slightly at T2 and dropped significantly at T30. However, no statistically significant differences in pH and flow rate were noticed in both the groups. Chewing of sugar-free gums in both caries-active and caries-free children may aid in reducing the incidence of dental caries.
Islas-Granillo, H; Borges-Yañez, S A; Medina-Solís, C E; Galan-Vidal, C A; Navarrete-Hernández, J J; Escoffié-Ramirez, M; Maupomé, G
2014-12-01
To compare a limited array of chewing-stimulated saliva features (salivary flow, pH and buffer capacity) in a sample of elderly Mexicans with clinical, sociodemographic and socio-economic variables. A cross-sectional study was carried out in 139 adults, 60 years old and older, from two retirement homes and a senior day care centre in the city of Pachuca, Mexico. Sociodemographic, socio-economic and behavioural variables were collected through a questionnaire. A trained and standardized examiner obtained the oral clinical variables. Chewing-stimulated saliva (paraffin method) was collected and the salivary flow rate, pH and buffer capacity were measured. The analysis was performed using non-parametric tests in Stata 9.0. Mean age was 79.1 ± 9.8 years. Most of the subjects included were women (69.1%). Mean chewing-stimulated salivary flow was 0.75 ± 0.80 mL/minute, and the pH and buffer capacity were 7.88 ± 0.83 and 4.20 ± 1.24, respectively. Mean chewing-stimulated salivary flow varied (p < 0.05) across type of retirement home, tooth brushing frequency, number of missing teeth and use of dental prostheses. pH varied across the type of retirement home (p < 0.05) and marginally by age (p = 0.087); buffer capacity (p < 0.05) varied across type of retirement home, tobacco consumption and the number of missing teeth. These exploratory data add to the body of knowledge with regard to chewing-stimulated salivary features (salivary flow rate, pH and buffer capacity) and outline the variability of those features across selected sociodemographic, socio-economic and behavioural variables in a group of Mexican elders.
Temperature-dependent erosivity of drinks in a model simulating oral fluid dynamics.
Steiger-Ronay, Valerie; Steingruber, Andrea; Becker, Klaus; Aykut-Yetkiner, Arzu; Wiedemeier, Daniel B; Attin, Thomas
2018-03-01
Aim of this investigation was to study the temperature-dependent in vitro enamel erosion of five acidic drinks and citric acid under controlled conditions in an artificial mouth. The erosive potential of Orange juice, Coca-Cola Zero, Sprite Zero, two fruit teas and citric acid (control) was investigated on bovine enamel specimens at temperatures between 5 °C and 55 °C. The pH values and total calcium content of all test drinks were determined. Specimens were immersed into an artificial mouth to imitate physiological oral conditions for 60 h. Cyclic de- and re-mineralization was performed, imitating the intake of six drinks in six h followed by a six-hour remineralization phase, where only artificial saliva ran over the specimens. Total erosive enamel loss was determined by contact profilometry. Differences in substance loss at different temperatures were tested for statistical significance (p-values ≤ 0.05) by means of ANOVA. Rising liquid temperature did not result in a considerable change of pH. Highest substance loss was observed for citric acid (33.6 ± 6 μm to 38.7 ± 6 μm), while only little erosion was induced by fruit tea (0.8 ± 1 μm to 5.9 ± 1 μm). Rising liquid temperature did not result in significantly increased substance loss for citric acid, orange juice and Coca-Cola Zero. Sprite Zero and both fruit teas, however, caused significantly (p < 0.001) more enamel loss at elevated temperature. Not all investigated drinks showed a temperature-induced change in erosivity. For some erosive beverages it can be recommended to keep the consummation temperature as low as possible to decrease the risk of erosive tooth substance loss. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fluoride release from glass ionomer restorative materials and the effects of surface coating.
Hattab, F N; Amin, W M
2001-06-01
This in vitro study on fluoride (F) release from conventional and metal-reinforced glass ionomer investigated the following: (1) the release of F in deionized water compared to artificial saliva, (2) the effect of various surface coatings on F release, (3) the uptake of released F by hydroxyapatite, (4) the expression of the release data in a mathematical model, (5) F content in the powders and set materials, and (6) surface morphology of varnished and resin-coated specimens. Glass ionomer Ketac-Fil (KF), Fuji II (FJ), and Ketac-Silver (KS) were mixed according to the manufacturers' instructions, and prepared into specimens of 137.8 mm2 surface area. All three specimens were suspended in 50 ml of deionized water, artificial saliva, or aqueous solution of hydroxyapatite and submitted to constant agitation at 37 degrees C. In a separate experiment, the specimens were coated with varnish or light-cured bonding resin and tested for F release in solutions similar to those for uncoated specimens. The release of F occurred for 28 days. The concentration of F was measured with F-ion-specific electrode. All tested products showed a strong initial rate of F release which decreased with time until it reached a relatively steady rate after two weeks. The F released from KF and FJ was comparable in both pattern and magnitude. They released approximately four times more F than KS. In all cases, the release of F in artificial saliva was significantly (p < 0.001) less than in deionized water. Surface coating the specimens significantly reduced the F release ( p < 0.05 top < 0.001, depending on the product and type of coating). The inhibitory effect of coating markedly decreased with time. Resin coating reduced F release more than varnish in KF and KS, but not for FJ. Essentially, all F released in aqueous solution was taken up by the hydroxyapatite, with FJ ranking the highest in increasing hydroxyapatite F concentration. Over the 28 days, the quantities of F released from FJ, KF, and KS were, respectively, 3.8, 2.3, and 1.0% of the total F content in the specimens. The F concentration in the set KS was 53.9 and 72.5% of that found in KF and FJ, respectively. The release data as a function of time were best described by the power curve. Micromorphological examinations revealed remnants of surface coatings on specimens after 14 days storage in artificial saliva. Glass ionomer cements released significantly less F in artificial saliva than in deionized water. Surface coating the specimens substantially reduced F release. These clinically relevant factors were not considered by many in vitro release studies which overestimate the F availability from glass ionomers. A recall appointment 24 h after the placement of glass ionomer restoration should be given for surface finishing.
Ability of barrier coat S-PRG coating to arrest artificial enamel lesions in primary teeth.
Hosoya, Yumiko; Ando, Susumu; Otani, Hideji; Yukinari, Tetsuhiro; Miyazaki, Masashi; Garcia-Godoy, Franklin
2013-10-01
To evaluate the effects of a surface pre-reacted glass-ionomer (S-PRG) filled coating material to arrest artificial enamel lesions in primary teeth. Buccal and lingual enamel was demineralized in 0.1 M lactic acid buffer solution (pH 4.75) for 5 days and then divided in the PRG-applied and non-PRG areas. Proximal surfaces were used as a control area without demineralization and coating application. Teeth were divided into three groups (n = 4) according to the 1-week immersion in different solutions: Group 1 (distilled water), Group 2 (demineralizing solution) and Group 3 (artificial saliva). Hardness and Young's modulus by nano-indentation test, and elemental contents and ultrastructure by SEM/EDX analysis were obtained. Data were statistically analyzed using ANOVA and Fisher's PLSD at alpha = 0.05. Only for the non-PRG area in Group 1, the hardness and Young's modulus of the demineralized surface enamel were significantly lower than those of the enamel 30-60 microm beneath the surface. Demineralized enamel of non-PRG and PRG-applied areas showed similar SEM views. Only for the non-PRG area in Group 2 and control area in Group 3, the Ca/P of the surface enamel was significantly higher than that of the enamel 5-10 microm beneath the surface. There was no significant difference of the Ca/P among the measuring points from the surface to 10 microm depth of enamel for the PRG applied area in Group 2.
Qiuxia, Yang; Ying, Yang; Han, Xu; Di, Wu; Ke, Guo
2016-02-01
This study aims to determine the effect of fluoride concentration on the corrosion behavior of cobalt-chromium alloy fabricated by two different technology processes in a simulated oral environment. A total of 15 specimens were employed with selective laser melting (SLM) and another 15 for traditional casting (Cast) in cobalt-chromium alloy powders and blocks with the same material composition. The corrosion behavior of the specimens was studied by potentiodynamic polarization test under different oral environments with varying solubilities of fluorine (0, 0.05%, and 0.20% for each) in acid artificial saliva (pH = 5.0). The specimens were soaked in fluorine for 24 h, and the surface microstructure was observed under a field emission scanning electron microscope after immersing the specimens in the test solution at constant temperature. The corrosion potential (Ecorr) value of the cobalt-chromium alloy cast decreased with increasing fluoride concentration in acidic artificial saliva. The Ecorr, Icorr, and Rp values of the cobalt-chromium alloy fabricated by two different technology processes changed significantly when the fluoride concentration was 0.20% (P < 0.05). The Ecorr, Icorr, and Rp values of the cobalt-chromium alloy fabricated by two different technology processes exhibited a statistically significant difference. The Icorr value of the cobalt-chromium alloy cast was higher than that in the SLM group cobalt-chromium alloy when the fluoride concentration was 0.20% (P < 0.05). The Ecorr, tRp alues of the cobalt-chromium alloy cast were lower htan those of the SLM group cobalt-chromium alloy when the fluoride concentration was 0.20% (P< 0 .05). Fluoride ions adversely affected the corrosion resistance of the cobalt-chromium alloy fabricated by two different technology processes. The corrosion resistance of the cobalt-chromium alloy cast was worse than that of the SLM group cobalt-chromium alloy when the fluoride concentration was 0.20%.
Comparison of the cariogenicity of some processed cheeses.
Drummond, B K; Chandler, N P; Meldrum, A M
2002-12-01
Cheeses have been investigated for their potential cariogenicity in several studies and have been shown to produce little change in the resting pH in dental plaque and little or no demineralisation of enamel in most intra-oral cariogenicity studies. The aim of the present study was to investigate the cariogenicity of four processed cheese formulations. Enamel demineralisation was measured intra-orally in bovine enamel, and aliquots of 10g of each test cheese were used to assess plaque pH using the plaque harvesting technique after the San Antonio criteria. In a second experiment, the same cheeses were assessed for their effects on enamel using the intra-oral cariogenicity test (ICT) with bovine enamel. None of the four cheeses caused pH drops below the critical pH and two of the cheeses raised the pH slightly. The effects on pH were all significantly different from those of the sucrose saliva control. None of the cheeses produced microhardness changes that were statistically significantly different from the saliva control. None of these cheeses as tested were found to lead to acidogenicity and by inference to be cariogenic. They were therefore deemed to be safe for teeth when used as a food.
Yuuki, Kenji; Tsukasaki, Hiroaki; Kawawa, Tadaharu; Shiba, Akihiko; Shiba, Kiyoko
2008-07-01
Clinical findings were compared with glucose, protein, albumin, bilirubin, creatinine, pH, occult blood, ketone body, nitrite, and white blood cells contained in whole saliva to investigate the components that most markedly reflect the periodontal condition. The subjects were staff of the Prosthodontics Department, Showa University, and patients who visited for dental treatments (57 subjects in total). At the first time, saliva samples were gargled with 1.5 ml of distilled water for 15 seconds and collected by spitting out into a paper cup. At the second time, saliva samples were collected by the same method. At the third time, saliva samples after chewing paraffin gum for 60 seconds were collected by spitting out into a paper cup. Thus whole saliva collecting that was divided on three times. After sampling, 8 mul of the saliva sample was dripped in reagent sticks for the 10 items of urinary test paper and the reflectance was measured using a specific reflectometer. In the periodontal tissue evaluation, the degree of alveolar bone resorption, probing value, and tooth mobility and the presence or absence of lesions in the root furcation were examined and classified into 4 ranks. The mean values in each periodontal disease rank and correlation between the periodontal disease ranks and the components were statistically analyzed. Bilirubin and ketone body were not measurable. The components density of the 8 items was increased as the periodontal disease rank increased. Regarding the correlation between the periodontal disease ranks and the components, high correlations were noted for protein, albumin, creatinine, pH, and white blood cells. The simultaneous measurement method of 8 salivary components using test paper may be very useful for the diagnosis of periodontal disease of abutment teeth.
Sereg-Bahar, M; Jerin, A; Jansa, R; Stabuc, B; Hocevar-Boltezar, I
2015-06-01
Laryngopharyngeal reflux (LPR) and biliary duodenogastric reflux can cause damage to the laryngeal mucosa and voice disorders. The aim of this study was to find out whether levels of pepsin and bile acids in the saliva can serve as diagnostic markers of LPR. A prospective comparative study. Twenty-eight patients with LPR proven via high-resolution manometry and combined multichannel intraluminal impedance and 24-h pH monitoring and 48 healthy controls without symptoms of LPR were included in the study. In the patients with LPR symptoms, oesophagogastroscopy with oesophageal biopsy was performed. The levels of total pepsin, active pepsin, bile acids and the pH of the saliva were determined in all participants and compared between the groups. Reflux symptom index (RSI) and reflux finding score (RFS) were also obtained and compared. The groups differed significantly in RSI (P = 0.00), RFS (P = 0.00), the levels of bile acids (P = 0.005) and total pepsin in saliva (P = 0.023). The levels of total pepsin and bile acids were about three times higher in the patients with LPR than in the healthy controls. There was a significant correlation between the RSI and RFS score and the level of total pepsin and bile acids in the saliva. Histopathological examination of the oesophageal biopsy taken 5 cm above the lower oesophageal sphincter confirmed reflux in almost 93% of patients with symptoms. The study results show that the levels of total pepsin and bile acids in saliva are significantly higher in patients with LPR than in the controls, thus suggesting this as a useful tool in the diagnosis of LPR and particularly biliary LPR. © 2014 John Wiley & Sons Ltd.
Xu, Shuai; Zhang, Ling; Li, Fang; Zhou, Wei; Chen, Yujiang; Chen, Jihua
2014-06-01
To systematically investigate the aging effect of thermocycling, water storage and bacteria aggression on the stability of resin-dentin bonds. Forty molars were sectioned perpendicularly to the axis of the teeth to expose the middle-coronal dentin surfaces. The dentin surfaces were then treated with Single Bond 2 and made a core build-up. According to random digits table, the bonding specimens were divided into four groups (n = 10) as follows: immediate control group, aging group with thermocycling for 5 000 times, aging group with artificial saliva storage for 6 months and aging group with bacteria aggression for 14 days. The specimens in each group were then subjected to microtensile bond strengths (µTBS) testing and nanoleakage evaluation respectively. After aging treatments, the three aging groups showed significantly lower µTBS than the immediate control group [(44.24 ± 12.75) MPa, P < 0.05]. The immediate control group also showed the lowest value of nanoleakage. The µTBS of aging group with bacteria aggression [(25.53 ± 7.39) MPa] was significantly lower than those of the other aging groups with artificial saliva storage[(29.72 ± 6.51) MPa] and thermocycling [(31.92 ± 11.87) MPa, P < 0.05]. There were no differences in the nanoleakage values among the three aging groups (P > 0.05). All the aging treatments with artificial saliva storage, thermocycling and bacteria aggression could accelerate the degradation of bonding interfaces between an etch-and-rinse adhesive and dentin. Bacteria aggression showed the most impairing effect on the stability of resin-dentin bonds.
Ion Release and Galvanic Corrosion of Different Orthodontic Brackets and Wires in Artificial Saliva.
Tahmasbi, Soodeh; Sheikh, Tahereh; Hemmati, Yasamin B
2017-03-01
To investigate the galvanic corrosion of brackets manufactured by four different companies coupled with stainless steel (SS) or nickel-titanium (NiTi) wires in an artificial saliva solution. A total of 24 mandibular central incisor Roth brackets of four different manufacturers (American Orthodontics, Dentaurum, Shinye, ORJ) were used in this experimental study. These brackets were immersed in artificial saliva along with SS or NiTi orthodontic wires (0.016'', round) for 28 days. The electric potential difference of each bracket/ wire coupled with a saturated calomel reference electrode was measured via a voltmeter and recorded constantly. Corrosion rate (CR) was calculated, and release of ions was measured with an atomic absorption spectrometer. Stereomicroscope was used to evaluate all samples. Then, samples with corrosion were further assessed by scanning electron microscope and energy-dispersive X-ray spectroscopy. Two-way analysis of variance was used to analyze data. Among ions evaluated, release of nickel ions from Shinye brackets was significantly higher than that of other brackets. The mean potential difference was significantly lower in specimens containing a couple of Shinye brackets and SS wire compared with other specimens. No significant difference was observed in the mean CR of various groups (p > 0.05). Microscopic evaluation showed corrosion in two samples only: Shinye bracket coupled with SS wire and American Orthodontics bracket coupled with NiTi wire. Shinye brackets coupled with SS wire showed more susceptibility to galvanic corrosion. There were no significant differences among specimens in terms of the CR or released ions except the release of Ni ions, which was higher in Shinye brackets.
Sajadi, Soodabeh Sadat; Eslami Amirabadi, Gholamreza; Sajadi, Sepideh
2014-07-01
Bond failure of brackets during orthodontic treatment is a common problem; which results in treatment interference, increased treatment time and prolonged clinical time for rebonding of failed brackets. The purpose of this study was to evaluate the effects of Coca-Cola and a non-alcoholic beer on the shear bond strength and adhesive remnant index (ARI) of orthodontic metal brackets in vitro. Eighty intact human premolars were divided into two experimental groups of Coca-Cola and non-alcoholic beer (Istak), and a control group of artificial saliva. Over a period of thirty days, the test groups were immersed in the respective soft drinks for 5 minutes, twice a day. For the remainder of the time, they were kept in artificial saliva at 37°C. The control group was stored in artificial saliva during the experiment. All samples were subjected to shearing forces using Universal Testing Machine. ARI was determined with a stereomicroscope at ×12 magnification. The data of shear bond strength were statistically analyzed by one-way ANOVA and Tukey's Post-Hoc test and the data of ARI scores were analyzed by Kruskal-Wallis test. No significant difference was observed in ARIs of the three groups (P≤ 0.552). The shear bond strength of Coke group was significantly lower than that of the two other groups (P≤ 0.035); but there was no significant difference between the shear bond strength of Istak and the control group (P≤ 0.999). Coca-Cola decreased the shear bond strength of orthodontic brackets.
Mirjalili, M; Momeni, M; Ebrahimi, N; Moayed, M H
2013-05-01
Localized corrosion and effects of pre-passivation treatment of Nitinol and SS304 orthodontic wires in simulated saliva solution in the presence and absence of fluoride ions were investigated by means of potentiodynamic and potentiostatic polarisations. Results revealed that Nitinol does not show pitting corrosion in saliva solution however, SS304 shows pitting corrosion. Meanwhile fluoride ion has deteriorative effect on pitting corrosion of Nitinol, while its effect on SS304 was marginally constructive. Additionally, the presence of artificial crevice has no effect on corrosion behaviour in the presence of fluoride. Pre-passivation treatment has positive influence on pitting corrosion of both alloys in the presence of F(-) ions. Copyright © 2012 Elsevier B.V. All rights reserved.
El-Deeb, H A; Al Sherbiney, H H; Mobarak, E H
2013-01-01
To evaluate the dentin bond strength durability of adhesives containing modified-monomer with/without-fluoride after storage in artificial saliva and under intrapulpal pressure simulation (IPPS). The occlusal enamel of 48 freshly extracted teeth was trimmed to expose midcoronal dentin. Roots were sectioned to expose the pulp chamber and to connect the specimens to the pulpal-pressure assembly. Specimens were assigned into four groups (n=12) according to adhesive system utilized: a two-step etch-and-rinse adhesive system (SB, Adper Single Bond 2, 3M ESPE), a two-step self-etch adhesive system (CSE, Clearfil SE Bond, Kuraray Medical Inc), and two single-step self-etch adhesives with the same modified monomer (bis-acrylamide)-one with fluoride (AOF, AdheSE One F, Ivoclar-Vivadent) and the other without (AO, AdheSE One, Ivoclar-Vivadent). Bonding was carried out while the specimens were subjected to 15-mm Hg IPPS. Resin composite (Valux Plus, 3M ESPE) buildups were made. After curing, specimens were aged in artificial saliva and under 20-mm Hg IPPS at 37°C in a specially constructed incubator either for 24 hours or six months prior to testing. Bonded specimens (n=6/group) were sectioned into sticks (n=24/group) with a cross section of 0.9 ± 0.01 mm(2) and subjected to microtensile bond strength (μTBS) testing using a universal testing machine. Data were statistically analyzed using two-way analysis of variance (ANOVA) with repeated measures, one-way ANOVA tests, and a t-test (p<0.05). Failure modes were determined using a scanning electron microscope. The μTBS values of SB and CSE fell significantly after six-month storage in artificial saliva and under IPPS, yet these values remained significantly higher than those for the other two adhesives with modified monomers. There was no significant difference in the bond strength values between fluoride-containing and fluoride-free self-etch adhesive systems (AOF and AO) after 24 hours or six months. Modes of failure were mainly adhesive and mixed. Based on the results of this study, 1) Fluoride addition did not affect dentin bond durability; and 2) despite the fact that the single-step adhesive system with modified monomer showed stability, bond strengths associated with these systems remained lower than those of multistep adhesive systems.
Dane, Asim; Gurbuz, Taskin
2016-01-01
Objective: To isolate Helicobacter pylori (HP) from the dental plaque of a selected group of children and to compare the oral and salivary findings of patients with those of a healthy control group. Methods: A total of 70 children aged 5–15 years were included in this study. An intraoral examination was performed for each patient, and dental plaque and saliva specimens were collected for analysis. Oral health conditions, nutritional habits, tooth brushing frequency, saliva pH levels, flow velocity, and buffering capacities were noted. The Kruskal–Wallis test was used for comparison of the DMFT and dft index. The significance level was set at p=0.05. Results: The prevalence of HP in dental plaque was higher in study group than controls (p<0.05). There were no significant differences between groups with respect to DMFT and dft scores, nutritional habits, tooth brushing frequency, saliva pH level or flow velocity (p>0.05). Meanwhile, the buffering capacity of saliva was lower in HP gastritis patients (p<0.05). Conclusion: There was a high prevalence of HP in dental plaque; thus, the oral cavity may be an important reservoir for HP. Good oral hygiene could be a positive contributor to the treatment of gastritis. PMID:27648050
Dane, Asim; Gurbuz, Taskin
2016-01-01
To isolate Helicobacter pylori (HP) from the dental plaque of a selected group of children and to compare the oral and salivary findings of patients with those of a healthy control group. A total of 70 children aged 5-15 years were included in this study. An intraoral examination was performed for each patient, and dental plaque and saliva specimens were collected for analysis. Oral health conditions, nutritional habits, tooth brushing frequency, saliva pH levels, flow velocity, and buffering capacities were noted. The Kruskal-Wallis test was used for comparison of the DMFT and dft index. The significance level was set at p=0.05. The prevalence of HP in dental plaque was higher in study group than controls (p<0.05). There were no significant differences between groups with respect to DMFT and dft scores, nutritional habits, tooth brushing frequency, saliva pH level or flow velocity (p>0.05). Meanwhile, the buffering capacity of saliva was lower in HP gastritis patients (p<0.05). There was a high prevalence of HP in dental plaque; thus, the oral cavity may be an important reservoir for HP. Good oral hygiene could be a positive contributor to the treatment of gastritis.
Oral yeast colonization throughout pregnancy.
Rio, R; Simões-Silva, L; Garro, S; Silva, M-J; Azevedo, Á; Sampaio-Maia, B
2017-03-01
Recent studies suggest that placenta may harbour a unique microbiome that may have origin in maternal oral microbiome. Although the major physiological and hormonal adjustments observed in pregnant women lead to biochemical and microbiological modifications of the oral environment, very few studies evaluated the changes suffered by the oral microbiota throughout pregnancy. So, the aim of our study was to evaluate oral yeast colonization throughout pregnancy and to compare it with non-pregnant women. The oral yeast colonization was assessed in saliva of 30 pregnant and non-pregnant women longitudinally over a 6-months period. Demographic information was collected, a non-invasive intra-oral examination was performed and saliva flow and pH were determined. Pregnant and non-pregnant groups were similar regarding age and level of education. Saliva flow rate did not differ, but saliva pH was lower in pregnant than in non-pregnant women. Oral yeast prevalence was higher in pregnant than in non-pregnant women, either in the first or in the third trimester, but did not attain statistical significance. In individuals colonized with yeast, the total yeast quantification (Log10CFU/mL) increase from the 1st to the 3rd trimester in pregnant women, but not in non-pregnant women. Pregnancy may favour oral yeast growth that may be associated with an acidic oral environment.
Salivary Distinctiveness and Modifications in Males with Diabetes and Behçet's Disease
Alhaffar, Iyad
2017-01-01
Oral diseases associated with systematic diseases as metabolic and vasculitic have been included in this paper. This will enhance our understanding of the salivary function in promoting healthy oral condition. The study investigates the effects of type I and type II diabetes mellitus in well-controlled diabetic patients, in addition to Behçet disease (BD) on saliva flow rate (SFR), pH, the decay, missing, and filled tooth (DMFT) index, glucose, and major earth-alkaline ions (Ca2+ and Mg2+) compared to healthy males and age-matched controls. Saliva samples were collected from 1403 male human subjects, distributed on 7 levels including 3 control groups, and analyzed. The symptoms and clinical observations were enrolled. A preprandial salivary glucose has illustrated statistically strong significant and positive correlations with HbA1c and blood glucose levels. TIDM saliva showed lower pH, SFR, and Ca2+ but higher Mg2+, caries risk, and poor metabolic control. These led to dysfunction of secretory capacity of salivary glands. TIIDM proved higher SFR, DMFT, and glucose than TIDM patients. DM oral calcium has decreased by age while magnesium sharply slopes at seniority. BD oral fluid is associated with lower glucose and minerals but noticeably with both higher pH and DMFT. PMID:28321337
Salivary Distinctiveness and Modifications in Males with Diabetes and Behçet's Disease.
Aljerf, Loai; Alhaffar, Iyad
2017-01-01
Oral diseases associated with systematic diseases as metabolic and vasculitic have been included in this paper. This will enhance our understanding of the salivary function in promoting healthy oral condition. The study investigates the effects of type I and type II diabetes mellitus in well-controlled diabetic patients, in addition to Behçet disease (BD) on saliva flow rate (SFR), pH, the decay, missing, and filled tooth (DMFT) index, glucose, and major earth-alkaline ions (Ca 2+ and Mg 2+ ) compared to healthy males and age-matched controls. Saliva samples were collected from 1403 male human subjects, distributed on 7 levels including 3 control groups, and analyzed. The symptoms and clinical observations were enrolled. A preprandial salivary glucose has illustrated statistically strong significant and positive correlations with HbA 1c and blood glucose levels. TIDM saliva showed lower pH, SFR, and Ca 2+ but higher Mg 2+ , caries risk, and poor metabolic control. These led to dysfunction of secretory capacity of salivary glands. TIIDM proved higher SFR, DMFT, and glucose than TIDM patients. DM oral calcium has decreased by age while magnesium sharply slopes at seniority. BD oral fluid is associated with lower glucose and minerals but noticeably with both higher pH and DMFT.
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor.
Arakawa, Takahiro; Kuroki, Yusuke; Nitta, Hiroki; Chouhan, Prem; Toma, Koji; Sawada, Shin-Ichi; Takeuchi, Shuhei; Sekita, Toshiaki; Akiyoshi, Kazunari; Minakuchi, Shunsuke; Mitsubayashi, Kohji
2016-10-15
We develop detachable "Cavitas sensors" to apply to the human oral cavity for non-invasive monitoring of saliva glucose. A salivary biosensor incorporating Pt and Ag/AgCl electrodes on a mouthguard support with an enzyme membrane is developed and tested. Electrodes are formed on the polyethylene terephthalate glycol (PETG) surface of the mouthguard. The Pt working electrode is coated with a glucose oxidase (GOD) membrane. The biosensor seamlessly is integrated with a glucose sensor and a wireless measurement system. When investigating in-vitro performance, the biosensor exhibits a robust relationship between output current and glucose concentration. In artificial saliva composed of salts and proteins, the glucose sensor is capable of highly sensitive detection over a range of 5-1000µmol/L of glucose, which encompasses the range of glucose concentrations found in human saliva. We demonstrate the ability of the sensor and wireless communication module to monitor saliva glucose in a phantom jaw imitating the structure of the human oral cavity. Stable and long-term real-time monitoring (exceeding 5h) with the telemetry system is achieved. The mouthguard biosensor will be useful as a novel method for real-time non-invasive saliva glucose monitoring for better management of dental patients. Copyright © 2015 Elsevier B.V. All rights reserved.
The effect of chewing gum's flavor on salivary flow rate and pH.
Karami-Nogourani, Maryam; Kowsari-Isfahan, Raha; Hosseini-Beheshti, Mozhgan
2011-12-01
Chewing sugar-free gums is a convenient way to increase salivary flow. Salivary flow increases in response to both gustatory (taste) and mechanical (chewing) stimuli, and chewing gum can provide both of these stimuli. The aim of this study was to compare the effect of five different flavors of sugar-free chewing gum on the salivary flow rate (SFR) and pH. Fifteen dental students volunteered at the same time on six consecutive days, to collect one minute unstimulated saliva. After five minutes, while some volunteers continued to collect only unstimulated saliva, the others asked to start chewing one of the five flavored gums randomly. The flavors were spearmint, cinnamon, watermelon, strawberry, and apple. The whole saliva was collected over time periods of 0 - 1, 1 - 3, and 3 - 6 minutes, and the SFR and pH were also measured. The data were subjected to pair t-test, repeated-measures analysis of variance, and Duncan tests. Compared to the unstimulated rate, all five different flavored gums significantly increased the SFR within six minutes. Although the flow rate peaked during the first minute of stimulation with all five products, it reduced gradually, but still remained above the unstimulated saliva, after six minutes. In the first minute, the strawberry-flavored gums showed the highest weight, yet, it only induced a significantly higher SFR compared to the cinnamon-flavored gums. During one to three minutes, strawberry and apple-flavored gums showed significantly higher SFR, respectively, compared to cinnamon-flavored gums. There were no significant differences in the flow rates elicited by each flavored gum through the three-to-six minute interval, although the spearmint-flavored gums induced slightly higher SFR. Only the spearmint and cinnamon-flavored gum significantly increased the salivary pH. Gum flavor can affect the SFR and special flavors may be advised for different individuals according to their oral conditions.
Oesophageal bioadhesion of sodium alginate suspensions: particle swelling and mucosal retention.
Richardson, J Craig; Dettmar, Peter W; Hampson, Frank C; Melia, Colin D
2004-09-01
This paper describes a prospective bioadhesive liquid dosage form designed to specifically adhere to the oesophageal mucosa. It contains a swelling polymer, sodium alginate, suspended in a water-miscible vehicle and is activated by dilution with saliva to form an adherent layer of polymer on the mucosal surface. The swelling of alginate particles and the bioadhesion of 40% (w/w) sodium alginate suspensions were investigated in a range of vehicles: glycerol, propylene glycol, PEG 200 and PEG 400. Swelling of particles as a function of vehicle dilution with artificial saliva was quantified microscopically using 1,9-dimethyl methylene blue (DMMB) as a visualising agent. The minimum vehicle dilution to initiate swelling varied between vehicles: glycerol required 30% (w/w) dilution whereas PEG 400 required nearly 60% (w/w). Swelling commenced when the Hildebrand solubility parameter of the diluted vehicle was raised to 37 MPa(1/2). The bioadhesive properties of suspensions were examined by quantifying the amount of sodium alginate retained on oesophageal mucosa after washing in artificial saliva. Suspensions exhibited considerable mucoretention and strong correlations were obtained between mucosal retention, the minimum dilution to initiate swelling, and the vehicle Hildebrand solubility parameter. These relationships may allow predictive design of suspensions with specific mucoretentive properties, through judicious choice of vehicle characteristics.
Determination of elemental composition of substance lost following wear of all-ceramic materials.
Dündar, Mine; Artunç, Celal; Toksavul, Suna; Ozmen, Dilek; Turgan, Nevbahar
2003-01-01
The aim of this study was to test the possible elemental release of four different all-ceramic materials in a wear machine to predict results about their long-term behavior in the oral environment. Four different all-ceramic materials with different chemical compositions were selected for the wear testing. A total of 20 cylindric samples, five for each ceramic group, were prepared according to the manufacturers' instructions. These were subjected to two-body wear testing in an artificial saliva medium under a covered unit with a computer-operated wear machine. The artificial saliva solutions for each material were analyzed for the determination of amounts of sodium, potassium, calcium, magnesium, and lithium elements released from the glass-ceramic materials. The differences between and within groups were statistically analyzed with a one-way ANOVA, followed by Duncan tests. The statistical analyses revealed no significant differences among Na, K, Ca, or Mg levels (P > .05) released from the leucite-reinforced groups, while there was a significant (P < .05) increase in Li release from the lithium disilicate group. Considerable element release to the artifical saliva medium was demonstrated in short-term wear testing. The lithia-based ceramic was more prone to Li release when compared with other elements and materials.
Ummadi, Jyothir Ganesh; Downs, Corey J; Joshi, Vrushali S; Ferracane, Jack L; Koley, Dipankar
2016-03-15
Solid-state ion-selective electrodes are used as scanning electrochemical microscope (SECM) probes because of their inherent fast response time and ease of miniaturization. In this study, we report the development of a solid-state, low-poly(vinyl chloride), carbon-based calcium ion-selective microelectrode (Ca(2+)-ISME), 25 μm in diameter, capable of performing an amperometric approach curve and serving as a potentiometric sensor. The Ca(2+)-ISME has a broad linear response range of 5 μM to 200 mM with a near Nernstian slope of 28 mV/log[a(Ca(2+))]. The calculated detection limit for Ca(2+)-ISME is 1 μM. The selectivity coefficients of this Ca(2+)-ISME are log K(Ca(2+),A) = -5.88, -5.54, and -6.31 for Mg(2+), Na(+), and K(+), respectively. We used this new type of Ca(2+)-ISME as an SECM probe to quantitatively map the chemical microenvironment produced by a model substrate, bioactive glass (BAG). In acidic conditions (pH 4.5), BAG was found to increase the calcium ion concentration from 0.7 mM ([Ca(2+)] in artificial saliva) to 1.4 mM at 20 μm above the surface. In addition, a solid-state dual SECM pH probe was used to correlate the release of calcium ions with the change in local pH. Three-dimensional pH and calcium ion distribution mapping were also obtained by using these solid-state probes. The quantitative mapping of pH and Ca(2+) above the BAG elucidates the effectiveness of BAG in neutralizing and releasing calcium ions in acidic conditions.
Evaluation of The Erosive Potential of Soft Drinks
de Carvalho Sales-Peres, Sílvia Helena; Magalhães, Ana Carolina; de Andrade Moreira Machado, Maria Aparecida; Buzalaf, Marília Afonso Rabelo
2007-01-01
Objectives This in vitro study evaluated the capability of different soft drinks (Coca-Cola®-C, Coca-Cola Light®-CL, Guaraná®-G, Pepsi Twist®-P and Sprite Light®-SL) to erode dental enamel, relating the percentage of superficial microhardness change (%SMHC) to concentrations of fluoride and phosphate, buffering capacity and pH of these drinks. Methods The soft drinks were evaluated in respect to concentration of phosphate and fluoride spectrophotometrically using Fiske, Subarrow method and by specific electrode (Orion 9609), respectively. The pH and the buffering capacity were determined by glass electrode and by estimating of the volume of NaOH necessary to change the pH of the drink in one unit, respectively. One hundred specimens of bovine enamel were randomly assigned to 5 groups of 20 each. They were exposed to 4 cycles of demineralisation in the beverage and remineralisation in artificial saliva. The softening of enamel was evaluated by %SMHC. Results The mean %SMHC was: C=77.27%, CL= 72.45%, SL=78.43%, G=66.65% and P=67.95%. Comparing the %SMHC promoted by 5 soft drinks, SL = C > CL > P = G (P<.05). There was not significant correlation between %SMHC and the other variables tested for the five drinks (P>.05). Conclusions The five soft drinks caused surface softening of enamel (erosion). In respect to the chemical variables tested, despite not statistically significant, the pH seems to have more influence on the erosive potential of these drinks. (Eur J Dent 2007;1:10–13) PMID:19212490
Prabhakar, A R; Mahantesh, T; Ahuja, Vipin
2010-01-01
The purpose of this study was to evaluate the efficacy of banding cements in terms of retentive capability and demineralization inhibition potential. We included 48 non-carious primary mandibular second molar teeth. Preformed stainless steel bands were adapted onto the teeth. All teeth were randomly assigned to four groups: Group I (Adaptation of bands without cementation), Group II (Cementation of bands using conventional Glass Ionomer Cement), Group III (Cementation of bands using Resin-modified Glass Ionomer Cement), Group IV (Cementation of bands using Resin cement), and placed in artificial saliva. Each day, specimens were taken from artificial saliva and suspended in an artificial caries solution for 35 minutes, every 8 hours. At the end of 3 months, retention of bands was estimated using an Instron Universal Testing Machine. The mode of failure was recorded and specimens were sectioned and examined under polarized microscope for demineralized lesions. The mean retention value was highest with resin cement, followed by RMGIC, GIC, and Control group respectively. The RMGIC group showed more favorable modes of failures. All the experimental groups showed significant demineralization inhibition potential. RMGIC is the preferable banding cement and can be used effectively to cement bands in primary dentition.
Mazaheri, Romina; Jabbarifar, Ebrahim; Ghasemi, Elnaz; Akkafzadeh, Elahe; Poursaeid, Elmira
2017-01-01
Acute lymphoblastic leukemia (ALL), accounting for 23% of all malignancies in children, is the most prevalent pediatric malignancy. This study compared dental caries, oral hygiene status, salivary pH, and Streptococcus mutans counts in dental plaques and saliva of children with leukemia with those of healthy controls. This case-control cross-sectional study assessed 32 children with ALL and 32 healthy children (4-9-year-old) for gingival bleeding index (GBI), decayed, missing, and filled/decayed, missing, and filled surfaces (DMF/dmfs), and plaque index (PI). Sampling was performed to determine salivary pH and S. mutans counts of the participants. The two groups matched in terms of age, gender, and socioeconomic status. The groups were compared using independent t-test, Mann-Whitney test, Chi-square test, and Spearman's and Pearson's correlation analyses. The mean DMF/dmfs and GBI were significantly higher in the ALL group (P DMF / dmfs = 0.03; P GBI = 0.04). However, the two groups were not significantly different in the mean PI values ( P = 0.47). The mean S. mutans counts in dental plaques and saliva of the children with leukemia were significantly lower than the healthy controls ( P < 0.01). Moreover, the mean salivary pH was significantly lower in the ALL group compared to the control group ( P < 0.01). Higher caries and gingival bleeding rates, higher dental plaque accumulation in children with ALL, decreased salivary pH, and cumulative effects of other risk factors highlight the significance of oral hygiene training programs (for the parents of these children) and regular dental examinations for these children.
Alkhateeb, Alaa A; Mancl, Lloyd A; Presland, Richard B; Rothen, Marilynn L; Chi, Donald L
2017-01-01
Salivary flow rate, pH, and buffering capacity are associated with dental caries, but studies from the cystic fibrosis (CF) literature are inconclusive regarding these salivary factors and caries. The aim of this study was to evaluate these factors and their associations with dental caries in individuals with CF. Unstimulated whole saliva was collected from individuals aged 6-20 years at Seattle Children's Hospital CF Clinic, USA (n = 83). Salivary flow rate was measured in milliliters per minute. Salivary pH was assessed using a laboratory pH meter. Buffering capacity was assessed by titration with HCl. The outcome measure was caries prevalence, defined as the number of decayed, missing, or filled primary and permanent tooth surfaces. Spearman's rank correlation coefficient and the t test were used to test for bivariate associations. Multiple variable linear regression models were used to (1) run confounder-adjusted analyses and (2) assess for potential interactions. There was no significant association between salivary flow rate or buffering capacity and caries prevalence. There was a significant negative association between salivary pH and caries prevalence, but this association was no longer significant after adjusting for age. There was no significant interaction between salivary flow rate and buffering capacity or between antibiotic use and the 3 salivary factors. Our results indicate that unstimulated salivary factors are not associated with dental caries prevalence in individuals with CF. Future studies should investigate other potential saliva-related caries risk factors in individuals with CF such as cariogenic bacteria levels, salivary host defense peptide levels, and medication use. © 2016 S. Karger AG, Basel.
Osteophagia provide giraffes with phosphorus and calcium?
Bredin, I P; Skinner, J D; Mitchell, G
2008-03-01
The daily requirement for calcium and phosphorus by giraffes to sustain the growth and maintenance of their skeletons is large. The source of sufficient calcium is browse. The source of necessary phosphorus is obscure, but it could be osteophagia, a frequently observed behaviour in giraffes. We have assessed whether bone ingested as a result of osteophagia can be digested in the rumen. Bone samples from cancellous (cervical vertebrae) and dense bones (metacarpal shaft) were immersed in the rumens of five sheep, for a period of up to 30 days, and the effect compared to immersion in distilled water and in artificial saliva for 30 days. Distilled water had no effect on the bones. Dense bone samples were softened by exposure to the saliva and rumen fluid, but did not lose either calcium or phosphorus. In saliva and rumen fluid the cancellous bone samples also softened, and their mass and volume decreased as a result of exposure to saliva, but in neither fluid did they lose significant amounts of calcium and phosphorus. We conclude that although saliva and rumen fluid can soften ingested bones, there is an insignificant digestion of bones in the rumen.
Sinfiteli, Priscila de Pinto; Coutinho, Thereza Christina Lopes; Oliveira, Patrícia Regina Almeida de; Vasques, Wesley Felisberto; Azevedo, Leandra Matos; Pereira, André Maues Brabo; Tostes, Monica Almeida
2017-01-01
Casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) complexes are anticariogenic and capable of remineralizing the early stages of enamel lesions. The use of fluoride prevents dental decay and the association of CPP-ACP with fluoride can increase remineralization. To evaluate the effect of CPP-ACP and CPP-ACPF creams associated with a fluoride dentifrice to prevent enamel demineralization in a pH cyclic model. Previously selected by surface microhardness (SH) analysis, human enamel blocks (n = 56) were submitted to daily treatment with dentifrice in a pH-cycling model. The enamel blocks were divided into four groups; G1: Crest™ Cavity Protection - Procter & Gamble (1,100 ppmF of NaF); G2: Crest™ +MI Paste (MP) - Recaldent™ GC Corporation Tokyo, Japan); G3: Crest™ + MI Paste Plus (MPP) - Recaldent™ 900 ppm as NaF, GC Corporation Tokyo, Japan), and G4: control, saliva. Specimens were soaked alternatively in a demineralizing solution and in artificial saliva for 5 d. The fluoride dentifrice, with proportion of 1:3 (w/w), was applied three times for 60 s after the remineralization period. The undiluted MP and MPP creams were applied for 3 m/d. After cycling, SH was re-measured and cross section microhardness measurements were taken. The SH values observed for the groups G3 (257±70), G1 (205±70), and G2 (208±84) differed from the G4 group (98±110) (one-way ANOVA and Tukey's post hoc test). There were no differences between the groups G1xG2, G2xG3, and G1xG3 for demineralization inhibition. The percentage of volume mineral showed that, when applied with fluoride dentifrice, MPP was the most effective in preventing enamel demineralization at 50 µ from the outer enamel surface (Kruskal-Wallis and Mann Whitney p<0.05). Fluoride dentifrice associated with CPP-ACPF inhibited subsurface enamel demineralization.
Kameda, Takashi; Ohkuma, Kazuo; Oda, Hirotake; Sano, Natsuki; Batbayar, Nomintsetseg; Terashima, Yukari; Sato, Soh; Terada, Kazuto
2013-01-01
Electric toothbrushes are widely used, and their electric motors have been reported to produce low-frequency electromagnetic fields that induced electric currents in metallic objects worn by the users. In this study, we showed that electric toothbrushes generated low-frequency magnetic fields (MFs) and induced electric currents in orthodontic appliances in artificial saliva (AS), which accelerated corrosion in stainless steel (SUS) appliances, but not in titanium (Ti) appliances; the corrosion was evaluated by using an inductively coupled plasma-optical emission spectrometer and a three-dimensional laser confocal microscope. The pH of AS used for appliance immersion did not change during or after MF exposure. These results suggested that MF-induced currents from electric toothbrushes could erode SUS appliances, but not Ti appliances, because of their high corrosion potentials. Further studies are required to clarify the mechanisms of metallic corrosion by induced currents in dental fields, which may trigger metal allergies in patients.
Corrosion anisotropy of titanium deformed by the hydrostatic extrusion
NASA Astrophysics Data System (ADS)
Chojnacka, A.; Kawalko, J.; Koscielny, H.; Guspiel, J.; Drewienkiewicz, A.; Bieda, M.; Pachla, W.; Kulczyk, M.; Sztwiertnia, K.; Beltowska-Lehman, E.
2017-12-01
The corrosion behaviour of titanium rods deformed by hydrostatic extrusion (HE) in artificial saliva (Carter-Brugirard's solution of pH 7.6) was investigated using open-circuit potentials (OCPs), (DC) potentiodynamic polarisation curves and (AC) electrochemical impedance spectroscopy (EIS) techniques. Various electrochemical parameters (corrosion potential Ecorr, corrosion current (icorr), polarisation resistance Rp, charge transfer resistance Rct and oxide film resistance Rf) were analysed. Significant coherence was observed between results achieved from these procedures, i.e., all applied techniques showed the same trend for corrosion resistance. The obtained electrochemical data were then related to the microstructure parameters (crystallographic texture, grain size, grain boundary distribution and density) determined using the EBSD/SEM technique. It was found that the corrosion behaviour of titanium processed by the HE method was superior compared to the unprocessed Ti, and this was clearly dependent on the extrusion direction. The highest corrosion resistance was revealed for the HE-deformed Ti rod of the surface oriented longitudinal (parallel) to the extrusion direction.
Zhang, Jingyang; Liu, Hongling; Liang, Xue; Zhang, Min; Wang, Renke; Peng, Guang; Li, Jiyao
2015-01-01
Radiation caries have been reported to be correlated with radiotherapy-induced destruction of salivary function and changes in oral microbiota. There have been no published reports detailing patients who have remained radiation caries-free following radiotherapy for nasopharyngeal carcinoma. The aim of this study was to investigate the relationship between salivary function, oral microbiota and the absence of radiation caries. Twelve radiation caries-free patients and nine patients exhibiting radiation caries following irradiated nasopharyngeal carcinoma were selected. V40, the dose at which the volume of the contralateral parotid gland receives more than 40 Gy, was recorded. Stimulated saliva flow rate, pH values and buffering capacity were examined to assess salivary function. Stimulated saliva was used for molecular profiling by Denaturing Gradient Gel Electrophoresis. Mutans streptococci and Lactobacilli in saliva were also cultivated. There were no significant differences in V40 between radiation caries-free individuals and those with radiation caries. Compared with normal values, the radiation caries-free group had significantly decreased simulated saliva flow rate, while there were no significant differences in the saliva pH value and buffering capacity. Similar results were observed in the radiation caries group. There was no statistical difference in microbial diversity, composition and log CFU counts in cultivation from the radiation caries-free group and the radiation caries group. Eleven genera were detected in these two groups, among which Streptococcus spp. and Neisseria spp. had the highest distribution. Our results suggest that changes in salivary function and in salivary microbiota do not explain the absence of radiation caries in radiation caries-free individuals. PMID:25860481
Zhang, Jingyang; Liu, Hongling; Liang, Xue; Zhang, Min; Wang, Renke; Peng, Guang; Li, Jiyao
2015-01-01
Radiation caries have been reported to be correlated with radiotherapy-induced destruction of salivary function and changes in oral microbiota. There have been no published reports detailing patients who have remained radiation caries-free following radiotherapy for nasopharyngeal carcinoma. The aim of this study was to investigate the relationship between salivary function, oral microbiota and the absence of radiation caries. Twelve radiation caries-free patients and nine patients exhibiting radiation caries following irradiated nasopharyngeal carcinoma were selected. V40, the dose at which the volume of the contralateral parotid gland receives more than 40 Gy, was recorded. Stimulated saliva flow rate, pH values and buffering capacity were examined to assess salivary function. Stimulated saliva was used for molecular profiling by Denaturing Gradient Gel Electrophoresis. Mutans streptococci and Lactobacilli in saliva were also cultivated. There were no significant differences in V40 between radiation caries-free individuals and those with radiation caries. Compared with normal values, the radiation caries-free group had significantly decreased simulated saliva flow rate, while there were no significant differences in the saliva pH value and buffering capacity. Similar results were observed in the radiation caries group. There was no statistical difference in microbial diversity, composition and log CFU counts in cultivation from the radiation caries-free group and the radiation caries group. Eleven genera were detected in these two groups, among which Streptococcus spp. and Neisseria spp. had the highest distribution. Our results suggest that changes in salivary function and in salivary microbiota do not explain the absence of radiation caries in radiation caries-free individuals.
The role of lipopolysaccharide on the electrochemical behavior of titanium.
Barão, V A; Mathew, M T; Assunção, W G; Yuan, J C; Wimmer, M A; Sukotjo, C
2011-05-01
Lipopolysaccharide (LPS) may induce peri-implantitis and implant failure. However, the role of LPS in titanium (Ti) electrochemical behavior remains unknown. We hypothesized that LPS in saliva with different pHs affects Ti corrosion properties. Thirty-six Ti discs (15 mm × 3 mm) were divided into 12 groups according to saliva pH (3, 6.5, and 9) and Escherichia coli LPS concentration (0, 0.15, 15, and 150 µg/mL). Electrochemical tests, such as open circuit potential, potentiodynamic, and electrochemical impedance spectroscopy, were conducted in a controlled environment. Data were evaluated by Pearson correlation and regression analysis (α = 0.05). LPS and pH affected Ti corrosive behavior. In general, lower pH and higher LPS concentration accelerated Ti corrosion. In the control group, the increase of pH significantly reduced the corrosion rate and increased the capacitance of the double layer. In LPS groups, the decrease of pH significantly increased the corrosion rate of Ti. LPS negatively influenced Ti corrosion behavior. C(dl), capacitance of double layer; E(corr), corrosion potential; EIS, electrochemical impedance spectroscopy; I(corr), corrosion current density; I(pass), passivation current density; LPS, lipopolysaccharide; OCP, open circuit potential; R(p), polarization resistance; Ti, titanium.
... and saliva. This causes a dry mouth and dry eyes. You may have dryness in other places that ... affected. It may include artificial tears for dye eyes and sucking on sugar-free candy or drinking water often for a dry mouth. Medicines may help with severe symptoms. NIH: ...
The Role of New Removable Complete Dentures in Stimulated Salivary Flow and Taste Perception.
Tango, Rubens Nisie; Arata, Anelyse; Borges, Alexandre Luiz Souto; Costa, Anna K F; Pereira, Luciano Jose; Kaminagakura, Estela
2018-04-01
To evaluate the effect of replacement of inadequate complete dentures on salivary flow and taste perception in geriatric patients. Thirty-three patients, 13 males and 20 females, with a mean age of 64.4 years were submitted to stimulated and unstimulated salivary flow rate and salivary pH measurements, and sense of taste evaluation. Tests were performed 3 months before complete denture substitution and 3 weeks after denture insertion. The mean for unstimulated saliva (USS) was 2.1 ml before and 2.7 ml after replacement (p = 0.003). The mean volume of stimulated saliva was 6.3 ml before and 8.2 ml after replacement (p = 0.004). The pH mean of USS was 7.8 ± 0.44 before and 8.02 ± 0.41 after replacement (p = 0.005). No statistically significant difference was determined in the sense of taste before and 3 weeks after complete denture replacement. The replacement of inadequate complete dentures increases saliva flow; however, it does not improve taste perception. © 2016 by the American College of Prosthodontists.
Paranhos, Helena de Freitas Oliveira; Salles, Antônio Eduardo Sparça; Macedo, Leandro Dorigan de; Silva-Lovato, Cláudia Helena da; Pagnano, Valéria Oliveira; Watanabe, Evandro
2013-01-01
This study compared the levels of biofilm in maxillary and mandibular complete dentures and evaluated the number of colony-forming units (cfu) of yeasts, after using auxiliary brushing agents and artificial saliva. Twenty-three denture wearers with hyposalivation and xerostomia were instructed to brush the dentures 3 times a day during 3 weeks with the following products: Corega Brite denture dentifrice, neutral liquid soap, Corega Brite combined with Oral Balance (artificial saliva) or tap water. For biofilm quantification, the internal surfaces of the dentures were disclosed, photographed and measured using a software. For microbiological analysis, the biofilm was scrapped off, and the harvested material was diluted, sown in CHROMagar™ Candida and incubated at 37°C for 48 h. Data were analyzed statistically by two-way ANOVA and Tukey's test (α=0.05). Mandibular dentures presented a mean biofilm percentage (µ=26.90 ± 21.10) significantly greater than the maxillary ones (µ=18.0 ± 15.0) (p<0.05). Brushing using Corega Brite combined with Oral Balance (µ=15.87 ± 18.47) was more effective (p<0.05) than using the denture dentifrice (µ=19.47 ± 17.24), neutral soap (µ=23.90 ± 18.63) or tap water (control; µ=32.50 ± 20.68). For the microbiological analysis, the chi-square test did not indicate significant difference between the hygiene products for either type of denture. The more frequently isolated species of yeasts were C. albicans, C. tropicalis and C. glabrata. In conclusion, mandibular dentures had more biofilm formation than maxillary ones. Denture brushing with Corega Brite dentifrice combined with the use of Oral Balance was the most effective method for reduction of biofilm levels, but the use of products did not show difference in yeast cfu counts.
Effect of natural gel product on bovine dentin erosion in vitro
SALES-PERES, André de Carvalho; MARSICANO, Juliane Avansini; GARCIA, Rudan Paraíso; FORIM, Moacir Rossi; da SILVA, Maria Fatima das Graças Fernandes; SALES-PERES, Sílvia Helena de Carvalho
2013-01-01
Objective To evaluate the efficacy of Neem (Azadirachta indica) experimental gel for the prevention of erosive wear on bovine dentin, in vitro. Material and Methods One hundred dentin blocks were allocated into 5 experimental groups (20 samples each): C (control group, without gel); CG (control group, only base gel); F (fluoride gel, 1.23% NaF; pH 4.1, Dentsply; Brazil); N (Neem gel, 10% neem extract; pH 4.1, manipulation); NF (Neem+fluoride gel, 10% Neem extract and 1.23% NaF; pH 4.1, manipulation). The blocks were stored in artificial saliva for 24 hours. After this, they were submitted to six alternating re- and demineralization cycles. The blocks were analyzed for wear (profilometry). The results were submitted to statistical analysis by ANOVA and Tukey tests (P<0.05). Results The mean wear (±SD, µm) was shown as follows in groups: C (13.09±0.99), CG (10.60±1.99), F (10.90±1.44), N (12.68±1.13) and NF (10.84±1.65). All gels showed some preventive action when compared with control group. However, significant differences were found only between Neem+fluoride gel and fluoride gel. Conclusion A single application of a neem-containing fluoride gel reduced dentin erosion, thus it is a possible alternative in reducing dental wear. Further research should investigate the action mechanism and the synergism between them. PMID:24473728
Effect of Popping Chocolate and Candy on Enamel Microhardness of Primary and Permanent Teeth.
Tabari, Mitra; Alaghemand, Homayoon; Qujeq, Durdi; Mohammadi, Elahe
2017-01-01
Dental erosion is a common disease in children. Food diets, due to high amounts of juice, soft drinks, chewing gum, and acidic chocolate, are one of the most important risk factors in erosive processes among children. The aim of this study was to evaluate the effect of candy and chocolate on the microhardness of tooth enamel. Two types of popping candy and one type of popping chocolate were used in this study. Thirty-three healthy permanent premolar teeth and 33 primary incisor teeth (A or B) were selected. Five grams of each popping chocolate or candy was dissolved with 2 ml of artificial saliva. Subsequently, their pH and titrable acidity (TA) as well as microhardness and surface roughness of enamel were examined in the laboratory. Data were analyzed and evaluated Released 2011. IBM SPSS Statistics for Windows, Version 20.0. Armonk, NY through independent t -test, paired t -test, Tukey test, and ANOVA. The results of this study showed that only the pH of the candies was below the critical pH of the enamel (5.5) and their TA was B = 0.20 and C = 0.21. The most significant effect on the enamel microhardness of the permanent and primary teeth was by the following types of candy: orange flavor (C), strawberry flavor (B), and chocolate (A), respectively. This difference was significant ( P < 0.001) and the surface roughness increased after exposure. This study showed that popping chocolate and candy reduces microhardness of enamel.
Saliva viscosity as a potential risk factor for oral malodor.
Ueno, Masayuki; Takeuchi, Susumu; Takehara, Sachiko; Kawaguchi, Yoko
2014-11-01
The objective of this study was to assess whether saliva viscosity, measured by a viscometer, was a predictor of oral malodor. The subjects were 617 patients who visited an oral malodor clinic. The organoleptic test (OT) was used for diagnosis of oral malodor. An oral examination assessed the numbers of teeth present and decayed teeth as well as the presence or absence of dentures. Further, periodontal pocket depths (PD), gingival bleeding, dental plaque and tongue coating were investigated. Unstimulated saliva were collected for 5 min. Saliva viscosity was measured with a viscometer. Logistic regression analysis with oral malodor status by OT as a dependent variable was performed. Possible confounders including age, gender, number of teeth present, number of decayed teeth, number of teeth with PD ≥ 4 mm, number of teeth with bleeding on probing, presence or absence of dentures, plaque index, area of tongue coating, saliva flow rate, saliva pH and saliva viscosity were used as independent variables. Saliva viscosity (p = 0.047) along with the number of teeth with PD ≥4 mm (p = 0.001), plaque index (p = 0.037) and area of tongue coating (p < 0.001) were significant variables for oral malodor. Subjects with a higher number of teeth with PD ≥ 4 mm (OR = 1.32), plaque index (OR = 2.13), area of tongue coating (OR = 3.17) and saliva viscosity (OR = 1.10) were more likely to have oral malodor compared to those with lower values. The results suggested that high saliva viscosity could be a potential risk factor for oral malodor.
[Surface aspect of fixed restaurations and parodontal influences].
Ciocan-Pendefunda, Alice-Arina; Forna, Norina Consuela
2012-01-01
Any new class of materials requires a new cutting technology which, unless complied with properly, may negatively impact on the advantages and performance of the material. The modifications appeared as a result of the technological processes in the structure or surface aspect of the materials not only affects the mechanical resistance of the restorations but also casts doubts on their biological qualities. This study evaluates the impact of biomaterials involved in fixed restorations on the periodontal architecture, bearing extremely important connotations in the long run. The "in vitro" testing was conducted on culture cells for the cytotoxic effect of certain restorative materials--metallic alloys used in prosthetic restorations, composite materials, in collaboration with the Virology Laboratory of the Public Health Institute.The tested materials were metallic alloys, composite materials and acrylic resins used for the construction of standard sized plates (out of each material) in order to avoid the differences that might arise from the technological process. Artificial saliva processed to reach a pH = 7 was prepared in the Biophysics Laboratory of UMF Iasi. Material samples and the saliva inoculated with these were tested. -p. The cytotoxic effect of the tested materials on the celular cultures takes on extremely diverse forms, from discrete morphological modifications of the cells with regard to the size, shape, internal structure (for the noble and semi-noble alloys) up to the partial stripping-off of the celular film, the modification of density and coloration. In the case of the witness of non-inoculated culture, the testing results showed the presence of a continuous film, with cells having the same size, transparency and colouring, with an unaltered polyhedral contour, with visible nuclei, an image also kept in the case of the saliva witness. The involvement of restaurative materials in triggering, maintaining and aggravating a periodontal pathology indicates the capital role played by the dentist in the identications of lesions during measures by avoiding or excluding etiological agents before an obvious lesions occurs in the process of active dispensarization.
Vishnubhotla, Gautam; Basapogu, Sreeramulu; Karnati, Rajeev Kumar Reddy; Dasari, Pradeep Prabhu; Thommandru, Mani Victor; Bethu, Mohana Bindu
2016-11-01
Dry retraction cords help to displace the gingiva and also to absorb the gingival crevicular fluid and saliva to maintain a dry field. When used along with medicaments whether these medicaments help to improve the absorption of fluid or affect the fluid absorption by decreasing the efficiency of the retraction cord is unknown. The aim of the study was to know the effect of various medicaments on the fluid absorbency of the retraction cords and also, to know whether the thickness of the retraction cords influences it's fluid absorbency. A total of 90 samples of 5cm length retraction cords were taken. Cords were divided into 30 samples for each cord thickness of 0, 1 and 2. Of these 30 samples, 10 samples were used to measure dry weight (Group I), 10 samples were immersed in 15.5% ferric sulfate (Group II) and remaining 10 samples were immersed in 10% aluminium chloride (Group III) for a period of 20 minutes. The excess medicament was removed by blotting paper. Initial weight was recorded. Following this, five cords from each group were immersed in plasma solution and remaining in artificial saliva for 10 minutes. Then these were taken out and measured. The amount of the fluid absorbed was determined by subtracting the weight before fluid immersion (weight after immersion in test medicament) from the weight after fluid immersion (weight after immersion in plasma or artificial saliva). The study was analyzed through one-way ANOVA and Bonferroni post-hoc comparisons for pair wise differences. When immersed in medicaments, there is a significant difference in absorption of fluids (artificial saliva and plasma) between the untreated dry cord and cord treated with 15.5% ferric sulfate (p<0.05). But, there was no significant difference in fluid absorption between the dry untreated cord and cord treated with 10% aluminum chloride and between cords treated with 15.5% ferric sulfate and 10% aluminum chloride. Ferric sulfate (15.5%) is a better medicament for absorption of fluid.
Zhang, Chao; Liu, Jiming; Yu, Wenwen; Sun, Daqian; Sun, Xinhua
2015-10-01
In this study, laser-welded composite arch wire (CAW) with a copper interlayer was exposed to artificial saliva containing salivary amylase or pancreatic amylase, and the resultant corrosion behavior was studied. The purpose was to determine the mechanisms by which salivary amylase and pancreatic amylase contribute to corrosion. The effects of amylase on the electrochemical resistance of CAW were tested by potentiodynamic polarization measurements. The dissolved corrosion products were determined by ICP-OES, and the surfaces were analyzed by SEM, AFM and EDS. The results showed that both exposure to salivary amylase and pancreatic amylase significantly improved the corrosion resistance of CAW. Even isozyme could have different influences on the alloy surface. When performing in vitro research of materials to be used in oral cavity, the effect of α-amylase should be taken into account since a simple saline solution does not entirely simulate the physiological situation. Copyright © 2015 Elsevier B.V. All rights reserved.
Chen, Lei; Cai, Hui; Xu, Guo-fu; Fang, Chang-yun
2006-06-01
To determine the effect of porcelain firing cycle on microstructure of 4 metal ceramic alloys, and to analyze the changes of their corrosion resistance in the artificial saliva. We simulated the process of firing and repolishing when fabricating porcelain-fused-to-metal restoration in clinic,and then observed the microstructures of Ni-Cr, Ni-Cr-Ti, Co-Cr alloys and high gold alloy by field emission scanning electron microscopy and energy dispersive spectroscopy. The electrochemical corrosion behavior of alloys in artificial saliva was analyzed by polarization curves and corrview 2 corrosion analysis software. The data of self-corrosion potential and transpassive potential were obtained and analyzed. After the porcelain firing cycle, the surface composition changed slightly, and the morphological in the 3 predominate base metal alloys also changed. The self-corrosion potential turned to more negative, and the transpassive potential declined. The procedure of porcelain firing cycle can affect the surface microstructure and increase the corrosion of 4 metal-ceramic alloys.
Iijima, Masahiro; Yuasa, Toshihiro; Endo, Kazuhiko; Muguruma, Takeshi; Ohno, Hiroki; Mizoguchi, Itaru
2010-01-01
This study investigated the corrosion properties of ion implanted nickel-titanium wire (Neo Sentalloy Ionguard) in artificial saliva and fluoride mouth rinse solutions (Butler F Mouthrinse, Ora-Bliss). Non ion implanted nickel-titanium wire (Neo Sentalloy) was used as control. The anodic corrosion behavior was examined by potentiodynamic polarization measurement. The surfaces of the specimens were examined with SEM. The elemental depth profiles were characterized by XPS. Neo Sentalloy Ionguard in artificial saliva and Butler F Mouthrinse (500 ppm) had a lower current density than Neo Sentalloy. In addition, breakdown potential of Neo Sentalloy Ionguard in Ora-Bliss (900 ppm) was much higher than that of Neo Sentalloy although both wires had similar corrosion potential in Ora-Bliss (450 and 900 ppm). The XPS results for Neo Sentalloy Ionguard suggested that the layers consisted of TiO(2) and TiN were present on the surface and the layers may improve the corrosion properties.
210Po in Human Saliva of Smokeless Tobacco Users.
Meli, Maria Assunta; Desideri, Donatella; Roselli, Carla; Feduzi, Laura
2017-01-01
The occurrence and mobility of Po in oral smokeless tobacco products (STPs) were determined because its effects on human health must be taken into account. This research was subdivided into two parts: determination by alpha spectrometry of the Po activity concentration in 16 oral smokeless tobacco products of different brands purchased in local specialty stores in Europe and evaluation of its percent extraction into an artificial salivary gland during sucking or chewing operations. Polonium-210 was detected in all samples, and its concentrations ranged from 3.46 to 14.8 Bq kg (mean value of 7.45 ± 3.82 Bq kg). The highest concentration was found in chewing tobacco. The samples showed no significant difference in the content of Po level. The data obtained in this study show that the polonium, although poorly extracted (12.8 ± 8.96%) by artificial saliva, is not totally retained within the smokeless tobacco products, with a consequent potential health hazard associated with oral use of these products.
Basir, Leila; Meshki, Razieh; Behbudi, Azam; Rakhshan, Vahid
2018-05-23
Nickel and chromium existing in stainless-steel crowns (SSCs, used in pediatric dentistry) might be cytotoxic and allergenic. However, no in vivo studies have examined their salivary levels in children using SSCs, or in young children without SSCs. Also, the effect of acidity on metal ion release has not yet been evaluated in any previous in vivo studies in the whole literature. Therefore, this preliminary before-after clinical trial was conducted. Salivary nickel/chromium levels of 30 children before and after 2 months of placement of SSCs were measured using atomic absorption spectrophotometry. Salivary pH was measured with a digital pH meter. The effects of treatment, pH, number of SSCs, gender, and age on salivary ions were analyzed statistically (α = 0.05, β = 0.15). Salivary nickel concentrations increased from 4.9010 ± 4.7390 to 5.6320 ± 4.7210 μg/L (P = 0.000, paired t test). Chromium increased from 0.3273 ± 0.5214 to 0.4199 ± 0.6404 μg/L (P = 0.016). Saliva pH increased from 6.81 ± 0.52 to 7.04 ± 0.47 (P = 0.000). Ion levels were not correlated with pH (P > 0.14), except chromium in the follow-up (rho = - 0.435, P = 0.016). Nickel increase (but not chromium increase) was correlated with pH increase (rho = 0.367, P = 0.046). Age was only correlated with baseline chromium (rho = 0.373, P = 0.042). Being male was associated with baseline/follow-up nickel levels (P ≤ 0.030). SSC number was not correlated with ions or pH (P > 0.36). It was shown for the first time that SSCs might increase salivary nickel and chromium concentrations and reduce saliva acidity. Nickel increase might be in line with pH elevation. The raised pH might be associated with reduced chromium release. Boys might have higher nickel levels than might girls, with or without SSCs.
Preiskorn, Joshua; Studer, Sophie; Rauh, Reinhold; Lukačin, Richard; Geffert, Christoph; Fleischhaker, Christian; Clement, Hans-Willi; Schulz, Eberhard; Biscaldi, Monica
2018-05-03
BackgroundTherapeutic drug monitoring (TDM) is becoming increasingly important in psychiatric therapy; especially in children. However, for several reasons, it cannot yet be implemented as a daily routine in clinical or outpatient settings. To evaluate new, non-invasive procedures; blood and saliva (oral fluid) samples were collected from patients with attention-deficit/hyperactivity disorder (ADHD) who were also being administered methylphenidate (MPH). The study's main purposes were to correlate MPH concentrations in serum and saliva between subjects; and to analyze intraindividual variation of serum concentration.MethodsThirty-six ADHD patients (27 children and 9 adults) on methylphenidate medication were included for drug analysis. MPH and its major metabolite ritalinic acid (RA) were quantified using LC-MS/MS measurements. The following correlations were investigated: 1) between drug concentrations in serum and saliva, and 2) between pH value and saliva to serum concentration ratio. Furthermore, the mean intraindividual MPH-concentration fluctuation in saliva under constant frame conditions was analyzed.ResultsAfter quantification, MPH concentrations were approximately 5 times higher in the saliva than in the serum, while the concentrations of RA were much lower in saliva. We found significant correlations between concentrations of MPH in serum and saliva (r=0.51, p<0.05). Saliva MPH measures, compared to serum, were pH-dependent(r=-0.56, p<0.01). Daily coefficient of variance of saliva concentration in children taking constant medication was 27.3% (11%-42 %), while the coefficient of variance for the ratio of saliva to serum was 122% (2%-2060%).ConclusionsOur data indicates that the interindividual variation in saliva to serum concentrations is rather high, while the intraindividual variation is fairly low, as already shown in the literature for repeated citalopram serum measurements. Saliva may well serve as an alternative matrix for TDM of MPH in ADHD patients, especially for follow-up examinations. Future research should focus on analyzing the relationship between drug levels in saliva and clinical effects; as well as on understanding the mechanisms that generate saliva drug concentrations. These are essential steps prior to potential clinical use.
Factors regulating astringency of whey protein beverages.
Beecher, J W; Drake, M A; Luck, P J; Foegeding, E A
2008-07-01
A rapidly growing area of whey protein use is in beverages. There are 2 types of whey protein-containing beverages: those at neutral pH and those at low pH. Astringency is very pronounced at low pH. Astringency is thought to be caused by compounds in foods that bind with and precipitate salivary proteins; however, the mechanism of astringency of whey proteins is not understood. The effect of viscosity and pH on the astringency of a model beverage containing whey protein isolate was investigated. Trained sensory panelists (n = 8) evaluated the viscosity and pH effects on astringency and basic tastes of whey protein beverages containing 6% wt/vol protein. Unlike what has been shown for alum and polyphenols, increasing viscosity (1.6 to 7.7 mPa.s) did not decrease the perception of astringency. In contrast, the pH of the whey protein solution had a major effect on astringency. A pH 6.8 whey protein beverage had a maximum astringency intensity of 1.2 (15-point scale), whereas that of a pH 3.4 beverage was 8.8 (15-point scale). Astringency decreased between pH 3.4 and 2.6, coinciding with an increase in sourness. Decreases in astringency corresponded to decreases in protein aggregation as observed by turbidity. We propose that astringency is related to interactions between positively charged whey proteins and negatively charged saliva proteins. As the pH decreased between 3.4 and 2.6, the negative charge on the saliva proteins decreased, causing the interactions with whey proteins to decrease.
Shafiee, Hadi; Kanakasabapathy, Manoj Kumar; Juillard, Franceline; Keser, Mert; Sadasivam, Magesh; Yuksekkaya, Mehmet; Hanhauser, Emily; Henrich, Timothy J.; Kuritzkes, Daniel R.; Kaye, Kenneth M.; Demirci, Utkan
2015-01-01
We report a biosensing platform for viral load measurement through electrical sensing of viruses on a flexible plastic microchip with printed electrodes. Point-of-care (POC) viral load measurement is of paramount importance with significant impact on a broad range of applications, including infectious disease diagnostics and treatment monitoring specifically in resource-constrained settings. Here, we present a broadly applicable and inexpensive biosensing technology for accurate quantification of bioagents, including viruses in biological samples, such as plasma and artificial saliva, at clinically relevant concentrations. Our microchip fabrication is simple and mass-producible as we print microelectrodes on flexible plastic substrates using conductive inks. We evaluated the microchip technology by detecting and quantifying multiple Human Immunodeficiency Virus (HIV) subtypes (A, B, C, D, E, G, and panel), Epstein-Barr Virus (EBV), and Kaposi’s Sarcoma-associated Herpes Virus (KSHV) in a fingerprick volume (50 µL) of PBS, plasma, and artificial saliva samples for a broad range of virus concentrations between 102 copies/mL and 107 copies/mL. We have also evaluated the microchip platform with discarded, de-identified HIV-infected patient samples by comparing our microchip viral load measurement results with reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR) as the gold standard method using Bland-Altman Analysis. PMID:26046668
Changes in human parotid salivary protein and sialic acid levels during pregnancy.
D'Alessandro, S; Curbelo, H M; Tumilasci, O R; Tessler, J A; Houssay, A B
1989-01-01
Saliva was collected with a Carlson-Crittenden device, under citric acid stimulation, in 107 pregnant women, 9 puerperal and 7 non-pregnant controls. No significant changes were found in salivary flow rate, pH and amylase levels. The total protein levels were decreased during pregnancy and the puerperium. The sialic acid levels decreased gradually but markedly during pregnancy, returning to normal levels in the puerperium. These changes in parotid saliva may be related to the hormonal changes of pregnancy.
Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav
2009-05-01
Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.
Ribelles Llop, M; Guinot Jimeno, F; Mayné Acién, R; Bellet Dalmau, L J
2010-03-01
The first studies on the use of chewing gum in dentistry were done in the 1970s. The Turku Sugar Studies, carried out between 1970 and 1973, showed the excellent anticaries properties of xylitol chewing gums. Since then, many dentists, particularly in Scandinavian countries, have studied the role of chewing xylitol-sweetened chewing gums as another preventive strategy in the control of dental caries. To compare variations in salivary flow rate, pH, buffering capacity, and levels of Streptococcus mutans in baseline conditions and after chewing paraffin pellets or xylitol chewing gum in children between the ages of 6 and 12 years who eat lunch in a school canteen. The study sample consisted of 90 children divided into 2 study groups, and a control group. The children ate lunch at the canteen of the Escultor Ortells state school in the town of Vila-real (Castellón, Spain). The baseline data recorded in the first phase of the study were compared with the data recorded in the second phase, after 15 minutes of chewing xylitol- sweetened chewing gums or paraffin pellets, depending on the study group. Salivary flow rate was measured by collecting the stimulated saliva in a graduated beaker. Levels of pH were measured using a Cyberscan pH 110 pH meter (Eutech Instruments). CRT buffer strips and the CRT bacteria test (Ivoclar-Vivadent) were used to measure buffering capacity and levels of S. mutans, respectively. The data obtained after sample collection were compared by means of a 1-way analysis of variance using the StatGraphics Plus statistical software package, version 5.0. Statistically significant differences were found (p<.05) when pH, buffering capacity and levels of S. mutans were compared between the 3 groups. Comparison of salivary flow rates revealed no statistically significant differences (p>.05), though salivary flow rates were higher in the groups where gum was chewed. The effect of chewing is essential to the stimulation of salivary flow and the resulting recovery of pH levels and reduction of levels of S. mutans in saliva.
Preston, K P; Higham, S M; Smith, P W
2007-06-01
The efficacy of three techniques for the disinfection of artificial sub-surface root caries lesions and their response to subsequent episodes of de- and remineralization was investigated quantitatively in vitro. Sub-surface dentinal lesions (n=20), cut into four experimental blocks and deliberately contaminated with Streptococcus mutans, were subject to either steam autoclaving (121 degrees C, 5min), gamma irradiation (4100Gy), immersion in 0.1% (w/v) thymol-distilled water solution (24h) or reserved as a control. Next, the lesions were incubated aerobically in sterile nutrient broth for 24h at 37 degrees C and resultant cultures plated onto blood agar and neutralisation agar. Ten blocks from each experimental group were then immersed in an acidic buffer solution or exposed to artificial saliva for 5 days. Baseline changes in the mineral content and distribution of the lesions were assessed by transverse microradiography (TMR). Micro-organisms were recovered from each control block and one block treated by gamma irradiation. Steam autoclaving and immersion in a thymol solution significantly decreased (p<0.05) the amount of mineral lost from the body of lesions subject to a further acid challenge. Mineral ion uptake by lesions exposed to artificial saliva was significantly increased (p<0.05) through disinfection by steam autoclaving. Gamma irradiation proved the most acceptable method for the disinfection of sub-surface root dentine lesions having the least adverse effect on demineralization and remineralization.
Jiang, F G; Lin, X Y; Yan, Z G; Hu, Z Y; Liu, G M; Sun, Y D; Liu, X W; Wang, Z H
2017-04-01
Increasing dietary roughage level is a commonly used strategy to prevent subacute ruminal acidosis. We hypothesized that high-roughage diets could promote chewing activity, saliva secretion, and hence more alkaline to buffer rumen pH. To verify the hypothesis, 12 multiparous Holstein cows in mid lactation were randomly allocated to 4 treatments in a triplicated 4 × 4 Latin square experiment with one cow in each treatment surgically fitted with a ruminal cannula. Treatments were diets containing 40, 50, 60, or 70% of roughage on a DM basis. Increasing dietary roughage level decreased DM, CP, OM, starch, and NE L intake, increased ADF intake, and decreased milk yield linearly. Intake of NDF was quite stable across treatments and ranged from 7.8 to 8.1 kg/d per cow. Daily eating time increased linearly with increased roughage level. The increase in eating time was due to increased eating time per meal but not number of meals per day, which was stable and ranged from 8.3 to 8.5 meals per day across treatments. Increasing dietary roughage level had no effect on ruminating time (min/d), the number of ruminating periods (rumination periods per d), and chewing time per ruminating period (min/ruminating period). Ruminating time per kilogram of NDF intake and total chewing time per kilogram of ADF intake were similar across treatments (57.4 and 183.8 min/kg, respectively). Increasing dietary roughage level linearly increased daily total chewing time; linearly elevated the mean, maximum, and minimum ruminal pH; and linearly decreased total VFA concentration and molar proportion of propionate in ruminal fluid. Saliva secretion during eating was increased, the secretion during rumination was unaffected, but the secretion during resting tended to decrease with increased dietary roughage level. As a result, total saliva secretion was not affected by treatments. In conclusion, the results of the present study did not support the concept that high-roughage diets elevated ruminal pH through increased salivary recycling of buffering substrates. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Caries prevalence in chronic alcoholics and the relationship to salivary flow rate and pH.
Dukić, Walter; Dobrijević, Tanja Trivanović; Katunarić, Marina; Lesić, Stjepanka
2013-03-01
The aim of this study was to investigate the dental status of alcoholics; to evaluate the relationship of unstimulated and stimulated saliva pH on their decayed/missing/filled teeth (DMFT); and to evaluate the relationship of unstimulated and stimulated salivary flow rate on their DMFT. A cross-sectional study was conducted in patients treated for alcohol dependency (n = 70; mean age 41.7 years) and a control group of non-alcoholics (n = 70; mean age 39.1 years). Examinations for dental caries were conducted using the World Health Organization (WHO) criteria and questionnaires. The correlation between nominal variables was determined using chi2 test (alpha = 0.05). The correlation between interval variables was determined using Pearson's correlation coefficient. The mean DMFT was similar in alcoholics (14.40) and the control group (13.44) (p > 0.05). There was a statistically significant correlation between alcoholism and unstimulated salivary flow rate (p < 0.05), but no relationship on DMFT was recorded. No statistically significant differences were found between alcoholics and controls in terms of stimulated salivary flow rate (p > 0.05) or stimulated salivary flow on DMFT (p > 0.05). There was a statistically significant correlation between alcoholism and the pH value of stimulated saliva (p < 0.01). There was no correlation between the amount of alcohol consumed and the number of carious lesions (p > 0.05). No major differences were found with respect to overall DMFT in alcoholics compared to the control group. Alcoholism and stimulated salivary flow rate showed no correlation. Unstimulated salivary flow rate as well as the pH values of both unstimulated and stimulated saliva, were lower in the alcoholic group.
Affinity interactions between natural pigments and human whole saliva.
Yao, Jiang-Wu; Lin, Feng; Tao, Tao; Lin, Chang-Jian
2011-03-01
The aim of the present study was to assess the null hypothesis that there are no differences of affinity between pigments and human whole saliva (WS), and the affinity is not influenced by the functional groups of pigments, temperatures, pH values, and salt concentrations. The affinity constants of interactions between WS and theaflavin (TF)/curcumin (Cur)/cyanidin (Cy) were determined by surface plasmon resonance (SPR) and fluorescence quenching. Mass-uptake at various temperatures, pH values, and salt concentrations was also carried out. The order of affinity of the pigments binding to WS is TF>Cur>Cy. A large number of complexes and precipitations of pigments/proteins were formed through a quick, strong, and almost irreversible binding process. The mass-uptake of pigments was affected not only by the functional groups, but also by molecular weight of pigments, temperatures, pH values, and salt concentrations. The complex of pigments may easily and rapidly deposit onto the WS film, and are difficult to remove from the WS surface. However, the complex of pigments can be reduced by properly regulating the physicochemical conditions, such as temperatures, pH values, and salt concentrations. Copyright © 2010 Elsevier Ltd. All rights reserved.
Ito, Tatsuro; Ichinosawa, Takahiro; Shimizu, Takehiko
2017-01-01
Streptococcus mutans, the major causative agent of dental caries, adheres to tooth surfaces via the host salivary glycoprotein-340 (gp340). This adherence can be competitively inhibited by peptides derived from the SspA/B adhesins of Streptococcus gordonii, a human commensal microbe that competes for the same binding sites. Ssp(A4K-A11K), a double-lysine substituted SspA/B peptide analogue, has been shown to exhibit superior in vitro binding affinity for a gp340-derived peptide (SRCRP2), suggesting that Ssp(A4K-A11K) may be of clinical interest. In the present work, we tested the inhibitory effects of Ssp(A4K-A11K) on adherence and biofilm formation of S. mutans by reconstructing an artificial oral environment using saliva-coated polystyrene plates and hydroxyapatite disks. Bacterial adherence (adherence period: 1 h) was assessed by an enzyme-linked immunosorbent assay using biotinylated bacterial cells. Biofilm formation (periods: 8, 11, or 14 h) was assessed by staining and imaging of the sessile cells, or by recovering biofilm cells and plating for cell counts. The pH values of the culture media were measured as a biofilm acidogenicity indicator. Bactericidality was measured by loss of optical density during culturing in the presence of the peptide. We observed that 650 μM Ssp(A4K-A11K) significantly inhibited adherence of S. mutans to saliva-coated polystyrene; a similar effect was seen on bacterial affinity for SRCRP2. Ssp(A4K-A11K) had lesser effects on the adherence of commensal streptococci. Pretreatment of polystyrene and hydroxyapatite with 650 μM Ssp(A4K-A11K) significantly attenuated biofilm formation, whether tested with glucose- or sucrose-containing media. The SspA/B peptide’s activity did not reflect bactericidality. Strikingly, pH in Ssp-treated 8-h (6.8 ± 0.06) and 11-h (5.5 ± 0.06) biofilms showed higher values than the critical pH. Thus, Ssp(A4K-A11K) acts by inhibiting bacterial adherence and cariogrnic biofilm formation. We further consider these results in the context of the safety, specificity, and stability properties of the Ssp(A4K-A11K) peptide. PMID:28394940
Pregnancy related changes in human salivary secretion and composition in a Nigerian population.
Lasisi, T J; Ugwuadu, P N
2014-12-01
A variety of physiological changes occurring during pregnancy has been shown to affect the oral health. Saliva is critical for preserving and maintaining the health of oral tissues and has been used as a source of non-invasive investigation of different conditions in human and animal studies. This study was designed to evaluate changes in secretion and composition of saliva in pregnant women in a Nigerian population. This was a descriptive cross-sectional study using purposive sampling technique. Saliva samples were collected from 50 pregnant and age matched 50 non-pregnant women. Salivary flow rate, pH, total protein and concentrations of sodium, potassium, calcium, phosphate and bicarbonate were determined and compared using paired independent sample t test. Salivary pH,mean concentrations of potassium and bicarbonate were significantly reduced while mean concentrations of salivary sodium and phosphate were significantly elevated in pregnant women compared to non-pregnant women (P < 0.05). However, there was no significant difference in the salivary flow rate, concentrations of total protein and calcium. Salivary pH, bicarbonate and potassium concentrations were reduced while sodium and phosphate concentrations were elevated in pregnant women. These findings suggest that pregnant women may be predisposed to higher caries incidence.
Lomate, Purushottam R.; Bonning, Bryony C.
2016-01-01
Stink bugs negatively impact numerous plant species of agricultural and horticultural importance. While efforts to develop effective control measures are underway, the unique digestive physiology of these pests presents a significant hurdle for either protein- or nucleotide-based management options. Here we report the comparative biochemical and proteomic characterization of proteases and nucleases from the gut, salivary gland and saliva of the southern green stink bug, Nezara viridula. The pH optimum for protease activity was acidic (5 to 6) in the gut with the primary proteases being cysteine proteases, and alkaline (8 to 9) in the saliva and salivary gland with the primary proteases being serine proteases. The serine proteases in saliva differ biochemically from trypsin and chymotrypsin, and the cathepsins in the gut and saliva showed distinct properties in inhibitor assays. Nuclease activity (DNase, RNase, dsRNase) was concentrated in the salivary gland and saliva with negligible activity in the gut. The most abundant proteins of the gut (530) and salivary gland (631) identified by proteomic analysis included four gut proteases along with eight proteases and one nuclease from the salivary gland. Understanding of N. viridula digestive physiology will facilitate the design of new strategies for management of this significant pest. PMID:27282882
Zhou, Jaclyn S; Chen, Angel Y S; Drucker, Martin; Lopez, Nicole H; Carpenter, Alyssa; Ng, James C K
2017-12-01
Transmission of plant viruses by phytophagous hemipteran insects encompasses complex interactions underlying a continuum of processes involved in virus acquisition, retention and inoculation combined with vector feeding behavior. Here, we investigated the effects of dietary pH on whitefly (Bemisia tabaci) feeding behavior and release of Lettuce infectious yellows virus (LIYV) virions retained in the vector's foregut. Electrical penetration graph analysis revealed that variables associated with whitefly probing and ingestion did not differ significantly in pH (4, 7.4, and 9) adjusted artificial diets. To investigate virus retention and release, whiteflies allowed to acquire LIYV virions in a pH 7.4 artificial diet were fed pH 4, 7.4, or 9 virion-free artificial (clearing) diets. Immunofluorescent localization analyses indicated that virions remained bound to the foreguts of approximately 20%-24% of vectors after they fed on each of the 3 pH-adjusted clearing diets. When RNA preparations from the clearing diets were analyzed by reverse transcription (RT) nested-PCR and, in some cases, real-time qPCR, successful amplification of LIYV-specific sequence was infrequent but consistently repeatable for the pH 7.4 diet but never observed for the pH 4 and 9 diets, suggesting a weak pH-dependent effect for virion release. Viruliferous vectors that fed on each of the 3 pH-adjusted clearing diets transmitted LIYV to virus-free plants. These results suggest that changes in pH values alone in artificial diet do not result in observable changes in whitefly feeding behaviors, an observation that marks a first in the feeding of artificial diet by whitefly vectors; and that there is a potential causal and contingent relationship between the pH in artificial diet and the release/inoculation of foregut bound virions. © 2017 Institute of Zoology, Chinese Academy of Sciences.
Effect of Popping Chocolate and Candy on Enamel Microhardness of Primary and Permanent Teeth
Tabari, Mitra; Alaghemand, Homayoon; Qujeq, Durdi; Mohammadi, Elahe
2017-01-01
Aims and Objectives: Dental erosion is a common disease in children. Food diets, due to high amounts of juice, soft drinks, chewing gum, and acidic chocolate, are one of the most important risk factors in erosive processes among children. The aim of this study was to evaluate the effect of candy and chocolate on the microhardness of tooth enamel. Materials and Methods: Two types of popping candy and one type of popping chocolate were used in this study. Thirty-three healthy permanent premolar teeth and 33 primary incisor teeth (A or B) were selected. Five grams of each popping chocolate or candy was dissolved with 2 ml of artificial saliva. Subsequently, their pH and titrable acidity (TA) as well as microhardness and surface roughness of enamel were examined in the laboratory. Data were analyzed and evaluated Released 2011. IBM SPSS Statistics for Windows, Version 20.0. Armonk, NY through independent t-test, paired t-test, Tukey test, and ANOVA. Results: The results of this study showed that only the pH of the candies was below the critical pH of the enamel (5.5) and their TA was B = 0.20 and C = 0.21. The most significant effect on the enamel microhardness of the permanent and primary teeth was by the following types of candy: orange flavor (C), strawberry flavor (B), and chocolate (A), respectively. This difference was significant (P < 0.001) and the surface roughness increased after exposure. Conclusions: This study showed that popping chocolate and candy reduces microhardness of enamel. PMID:29387623
Effect of four over-the-counter tooth-whitening products on enamel microhardness.
Majeed, A; Grobler, S R; Moola, M H; Oberholzer, T G
2011-10-01
This in vitro study evaluated the effect of four over-the-counter tooth-whitening products on enamel microhardness. Fifty enamel blocks were prepared from extracted human molar teeth. The enamel surfaces were polished up to 1200 grit fineness and the specimens randomly divided into five groups. Enamel blocks were exposed to: Rapid White (n=10); Absolute White (n=10); Speed White (n=10) and White Glo (n=10) whitening products, according to the manufacturers' instructions. As control, ten enamel blocks were kept in artificial saliva at 37 degrees C without any treatment. Microhardness values were obtained before exposure (baseline) and after 1, 7 and 14-day treatment periods using a digital hardness tester with a Vickers diamond indenter. Data were analysed using Wilcoxon Signed Rank Sum Test, one-way ANOVA and Tukey-Kramer Multiple Comparison Test (p<0.05). Both Rapid White and Absolute White reduced enamel microhardness. Speed White increased the microhardness of enamel, while White Glo and artificial saliva had no effect on hardness. Over-the-counter tooth-whitening products might decrease enamel microhardness depending on the type of product.
Li, Lei; Li, Shunling; Qu, Qing; Zuo, Limei; He, Yue; Zhu, Baolin; Li, Cong
2017-01-01
Bacteria biofilm formation on metals is well-known, while biofilm architecture varies under different conditions. To date, few studies have determined the possible contribution to corrosion of titanium made by biofilm architecture. We investigated the interaction between the oral Streptococcus sanguis biofilm architecture and its influence on titanium corrosion in enriched artificial saliva using electrochemical methods and microscopic study. Patchy biofilms were observed on titanium surface after being immersed in solution containing S. sanguis. The thickness and size of the patchy biofilms increased with an increase of immersion time. The extensive pits were clearly observed by scanning electron microscopy, showing that adsorption of S. sanguis on titanium promoted the localized corrosion. The electrochemical results indicated that the corrosion rates were clearly accelerated in the presence of S. sanguis. The low icorr and high Rt in the first 48 h indicated that a typical passive behavior still remained. Our study showed that the pitting corrosion of titanium was mainly attributed to the formation of a self-catalytic corrosion cell by the co-effect of patchy biofilm and organic acid secreted by S. sanguis. PMID:28772615
Li, Lei; Li, Shunling; Qu, Qing; Zuo, Limei; He, Yue; Zhu, Baolin; Li, Cong
2017-03-03
Bacteria biofilm formation on metals is well-known, while biofilm architecture varies under different conditions. To date, few studies have determined the possible contribution to corrosion of titanium made by biofilm architecture. We investigated the interaction between the oral Streptococcus sanguis biofilm architecture and its influence on titanium corrosion in enriched artificial saliva using electrochemical methods and microscopic study. Patchy biofilms were observed on titanium surface after being immersed in solution containing S. sanguis . The thickness and size of the patchy biofilms increased with an increase of immersion time. The extensive pits were clearly observed by scanning electron microscopy, showing that adsorption of S. sanguis on titanium promoted the localized corrosion. The electrochemical results indicated that the corrosion rates were clearly accelerated in the presence of S. sanguis . The low i corr and high R t in the first 48 h indicated that a typical passive behavior still remained. Our study showed that the pitting corrosion of titanium was mainly attributed to the formation of a self-catalytic corrosion cell by the co-effect of patchy biofilm and organic acid secreted by S. sanguis .
Pavlovian conditioning of phobic fear: effects on skin and salivary pH.
Chorot, P; Sandin, B; Fernandez-Trespalacios, J L
1992-01-01
This experimental work was designed to investigate the relationships between pH and conditioned fear. The levels of pH were measured in skin and saliva, and were studied in connection with conditioned electrodermal and heart rate (HR) responses (extinction versus resistance to extinction or enhancement). The results of this investigation show that the changes in skin and salivary pH have a tendency to occur in an inverse pattern to the changes in skin conductance and HR. The data are interpreted in terms of skin and salivary pH as new psychophysiological variables and as new tools for psychopathological and psychosomatic research.
NASA Astrophysics Data System (ADS)
Srinivasan, Samuelraj; Prabhu, Vijendra; Chandra, Subhash; Koshy, Shalini; Acharya, Shashidhar; Mahato, Krishna K.
2014-02-01
The present era of minimal invasive dentistry emphasizes the early detection and remineralization of initial enamel caries. Ozone has been shown to reverse the initial demineralization before the integrity of the enamel surface is lost. Nano-hydroxyapatite is a proven remineralizing agent for early enamel caries. In the present study, the effect of ozone in enhancing the remineralizing potential of nano-hydroxyapatite on artificially demineralized enamel was investigated using laser induced fluorescence. Thirty five sound human premolars were collected from healthy subjects undergoing orthodontic treatment. Fluorescence was recorded by exciting the mesial surfaces using 325 nm He-Cd laser with 2 mW power. Tooth specimens were subjected to demineralization to create initial enamel caries. Following which the specimens were divided into three groups, i.e ozone (ozonated water for 2 min), without ozone and artificial saliva. Remineralization regimen was followed for 3 weeks. The fluorescence spectra of the specimens were recorded from all the three experimental groups at baseline, after demineralization and remineralization. The average spectrum for each experimental group was used for statistical analysis. Fluorescence intensities of Ozone treated specimens following remineralization were higher than that of artificial saliva, and this difference was found to be statistically significant (P<0.0001). In a nutshell, ozone enhanced the remineralizing potential of nanohydroxyapatite, and laser induced fluorescence was found to be effective in assessing the surface mineral changes in enamel. Ozone can be considered an effective agent in reversing the initial enamel caries there by preventing the tooth from entering into the repetitive restorative cycle.
A comparison of sports and energy drinks--Physiochemical properties and enamel dissolution.
Jain, Poonam; Hall-May, Emily; Golabek, Kristi; Agustin, Ma Zenia
2012-01-01
The consumption of sports and energy drinks by children and adolescents has increased at an alarming rate in recent years. It is essential for dental professionals to be informed about the physiochemical properties of these drinks and their effects on enamel. The present study measured the fluoride levels, pH, and titratable acidity of multiple popular, commercially available brands of sports and energy drinks. Enamel dissolution was measured as weight loss using an in vitro multiple exposure model consisting of repeated short exposures to these drinks, alternating with exposure to artificial saliva. The relationship between enamel dissolution and fluoride levels, pH, and titratable acidity was also examined. There was a statistically significant difference between the fluoride levels (p = 0.034) and pH (p = 0.04) of the sports and energy drinks studied. The titratable acidity of energy drinks (11.78) was found to be significantly higher than that of sports drinks (3.58) (p < 0.001). Five of the energy drinks (Red Bull Sugar Free, Monster Assault, Von Dutch, Rockstar, and 5-Hour Energy) were found to have the highest titratable acidity values among the brands studied. Enamel weight loss after exposure to energy drinks was significantly higher than it was after exposure to sports drinks. The effect of titratable acidity on enamel weight loss was found to vary inversely with the pH of the drinks. The findings indicated that energy drinks have significantly higher titratable acidity and enamel dissolution associated with them than sports drinks. Enamel weight loss after exposure to energy drinks was more than two times higher than it was after exposure to sports drinks. Titratable acidity is a significant predictor of enamel dissolution, and its effect on enamel weight loss varies inversely with the pH of the drink. The data from the current study can be used to educate patients about the differences between sports and energy drinks and the effects of these drinks on tooth enamel.
Ion release and cytotoxicity of stainless steel wires.
Oh, Keun-Taek; Kim, Kyoung-Nam
2005-12-01
Heat treatment is generally applied to orthodontic stainless steel (SS) wires to relieve the stresses that result from their manipulation by orthodontists. The quality and thickness of the oxide films formed on the surface of heat-treated wires can vary, and it is believed that these oxide films can influence the properties of heat-treated wires. The aim of this study was to investigate the influence of heat treatment and cooling methods on the amount of metal ions released and to examine the cytotoxicity of heat-treated wires. In this study, four types of SS wires (Remanium, Permachrome, Colboloy and Orthos) with a cross-sectional area of 0.41 x 0.56 mm were investigated. These wires were heat-treated in a vacuum, air, or argon environment, and were cooled in either a furnace or a water bath. Four control groups and 24 experimental groups were classified according to the type of wires, heat treatment conditions and cooling methods. In each group, the amount of nickel released as well as its cytotoxicity was investigated. The concentration of dissolved nickel ions in artificial saliva was measured for a period of up to 12 weeks. In all groups, the concentration of dissolved nickel ions in artificial saliva was lowest for the vacuum heat treatment-furnace cooling group and a significant difference was shown compared with the other experimental groups. The concentration of dissolved nickel ions in artificial saliva was highest in the groups heat-treated in air (P < 0.05), while the amount of nickel released was highest in the Remanium and Colboloy (P < 0.05). The cytotoxicity was mild in all the experimental groups but the response index of the air groups was slightly higher than in the other groups. According to these results, SS wires retain their high corrosion resistance and low ion release rate when heat-treated in a vacuum and cooled in a furnace.
Yang, Ze-min; Chen, Long-hui; Lin, Jing; Zhang, Min; Yang, Xiao-rong; Chen, Wei-wen
2015-02-01
To compare the effect of citric acid stimulation on salivary alpha-amylase (sAA), total protein (TP), salivary flow rate, and pH value between Pi deficiency (PD) children and healthy children, thereby providing evidence for Pi controlling saliva theory. Twenty PD children were recruited, and 29 healthy children were also recruited at the same time. Saliva samples from all subjects were collected before and after citric acid stimulation. The sAA activity and amount, TP contents, salivary flow rate, and pH value were determined and compared. (1) Citric acid stimulation was able to significantly increase salivary flow rate, pH value, sAA activities, sAA specific activity and sAA amount (including glycosylated and non-glycosylated sAA amount) in healthy children (P<0.05), while it could markedly increase salivary flow rate, pH value, and glycosylated sAA levels in PD children (P<0.05); (2) Although there was no statistical difference in determined salivary indices between the two groups (P>0.05), salivary indices except salivary flow rate and glycosylated sAA levels decreased more in PD children. There was statistical difference in sAA activity ratio, sAA specific activity ratio, and the ratio of glycosylated sAA levels between PD children and healthy children (P<0.05). PD children had decreased response to citric acid stimulation.
Erosive effects of common beverages on extracted premolar teeth.
Seow, W K; Thong, K M
2005-09-01
Dental erosion is highly prevalent today, and acidic drinks are thought to be an important cause. The aim of the present investigation was to determine the erosive potential of a range of common beverages on extracted human teeth. The beverages were tested for their individual pHs using a pH meter. The clinical effects of the most erosive beverages were determined by the degree of etching and Vickers microhardness of enamel. The results showed that many common beverages have pHs sufficiently low to cause enamel erosion. Lime juice concentrate (pH 2.1) had the lowest pH, followed by Coca-cola and Pepsi (both with pH 2.3) and Lucozade (pH 2.5). The erosive potential of these beverages was demonstrated by the deep etching of the enamel after five minutes. The Vickers Hardness of enamel was reduced by about 50 per cent in the case of lime juice (p < 0.001) and 24 per cent in the case of Coca-cola (p < 0.004). Addition of saliva to 50 per cent (v/v) of Coca-cola completely reversed the erosive effects on the enamel. Although only a few of the beverages with the lowest pHs were tested, the present study showed that the most acidic drinks had the greatest erosive effects on enamel. While saliva was protective against erosion, relatively large volumes were required to neutralize the acidity.
Proteomic Profiling of Cereal Aphid Saliva Reveals Both Ubiquitous and Adaptive Secreted Proteins
Wilkinson, Tom L.
2013-01-01
The secreted salivary proteins from two cereal aphid species, Sitobion avenae and Metopolophium dirhodum, were collected from artificial diets and analysed by tandem mass spectrometry. Protein identification was performed by searching MS data against the official protein set from the current pea aphid (Acyrthosiphon pisum) genome assembly and revealed 12 and 7 proteins in the saliva of S. avenae and M. dirhodum, respectively. When combined with a comparable dataset from A. pisum, only three individual proteins were common to all the aphid species; two paralogues of the GMC oxidoreductase family (glucose dehydrogenase; GLD) and ACYPI009881, an aphid specific protein previously identified as a putative component of the salivary sheath. Antibodies were designed from translated protein sequences obtained from partial cDNA sequences for ACYPI009881 and both saliva associated GLDs. The antibodies detected all parent proteins in secreted saliva from the three aphid species, but could only detect ACYPI009881, and not saliva associated GLDs, in protein extractions from the salivary glands. This result was confirmed by immunohistochemistry using whole and sectioned salivary glands, and in addition, localised ACYPI009881 to specific cell types within the principal salivary gland. The implications of these findings for the origin of salivary components and the putative role of the proteins identified are discussed in the context of our limited understanding of the functional relationship between aphid saliva and the plants they feed on. The mass spectrometry data have been deposited to the ProteomeXchange and can be accessed under the identifier PXD000113. PMID:23460852
Proteomic profiling of cereal aphid saliva reveals both ubiquitous and adaptive secreted proteins.
Rao, Sohail A K; Carolan, James C; Wilkinson, Tom L
2013-01-01
The secreted salivary proteins from two cereal aphid species, Sitobion avenae and Metopolophium dirhodum, were collected from artificial diets and analysed by tandem mass spectrometry. Protein identification was performed by searching MS data against the official protein set from the current pea aphid (Acyrthosiphon pisum) genome assembly and revealed 12 and 7 proteins in the saliva of S. avenae and M. dirhodum, respectively. When combined with a comparable dataset from A. pisum, only three individual proteins were common to all the aphid species; two paralogues of the GMC oxidoreductase family (glucose dehydrogenase; GLD) and ACYPI009881, an aphid specific protein previously identified as a putative component of the salivary sheath. Antibodies were designed from translated protein sequences obtained from partial cDNA sequences for ACYPI009881 and both saliva associated GLDs. The antibodies detected all parent proteins in secreted saliva from the three aphid species, but could only detect ACYPI009881, and not saliva associated GLDs, in protein extractions from the salivary glands. This result was confirmed by immunohistochemistry using whole and sectioned salivary glands, and in addition, localised ACYPI009881 to specific cell types within the principal salivary gland. The implications of these findings for the origin of salivary components and the putative role of the proteins identified are discussed in the context of our limited understanding of the functional relationship between aphid saliva and the plants they feed on. The mass spectrometry data have been deposited to the ProteomeXchange and can be accessed under the identifier PXD000113.
Evaluation of salivary surface tension in a cohort of young healthy adults.
Foglio-Bonda, P L; Laguini, E; Davoli, C; Pattarino, F; Foglio-Bonda, A
2018-03-01
To determine salivary pH, flow rate (FR) and surface tension (γs) in a cohort of 30 healthy young adults. To acquire cohort biological independent variables (age, gender, weight, height, medications, smoking, pathologies, and allergies) and to correlate them with pH, FR and γs obtained values. Evaluate the possible variation of the γs values during the time after the withdrawal and the influence of the operational abilities of the experimenting operators. Evaluate the relationship between γs, pH and FR and the dependence between pH and FR. Non-stimulated saliva samples were taken in four different time span, for three days, with a drooling method for 15 minutes. The saliva sample was analyzed, in terms of γs, by two different operators (OP1 and OP2), twice consecutive (γs-1 and γs-2) for a total of 360 measurements. The γs was calculated using the du Noüy method. The FR was evaluated by weighing technique and pH by pH indicator papers. The measurements of γs performed by two different operators (OP1, OP2) showed respectively average values of 46.46 mN/m and 43.45 mN/m, while the mean FR was 0.29 ± 0.13 mL/min and the average pH was 7.1 ± 0.43. There were no significant correlations between γs and the biological variables analyzed. We can consider as reference values, in a sample of young adults, γs 45.56 ± 6.51 mN/m.
Ahmadi-Motamayel, Fatemeh; Falsafi, Parisa; Goodarzi, Mohammad T.; Poorolajal, Jalal
2016-01-01
Objectives: Saliva contains alkaline phosphatase (ALP)—a key intracellular enzyme related to destructive processes and cellular damage—and has buffering capacity (BC) against acids due to the presence of bicarbonate and phosphate ions. Smoking may have deleterious effects on the oral environment due to pH changes which can affect ALP activity. This study aimed to evaluate the salivary pH, BC and ALP activity of male smokers and healthy non-smokers. Methods: This retrospective cohort study took place between August 2012 and December 2013. A total of 251 healthy male non-smokers and 259 male smokers from Hamadan, Iran, were selected. Unstimulated whole saliva was collected from each participant and pH and BC were determined using a pH meter. Salivary enzymes were measured by spectrophotometric assay. Results: Mean salivary pH (7.42 ± 0.48 and 7.52 ± 0.43, respectively; P = 0.018) and BC (3.41 ± 0.54 and 4.17 ± 0.71; P = 0.001) was significantly lower in smokers compared to non-smokers. Mean ALP levels were 49.58 ± 23.33 IU/L among smokers and 55.11 ± 27.85 IU/L among non-smokers (P = 0.015). Conclusion: Significantly lower pH, BC and ALP levels were observed among smokers in comparison to a healthy control group. These salivary alterations could potentially be utilised as biochemical markers for the evaluation of oral tissue function and side-effects among smokers. Further longitudinal studies are recommended to evaluate the effects of smoking on salivary components. PMID:27606111
Ahmadi-Motamayel, Fatemeh; Falsafi, Parisa; Goodarzi, Mohammad T; Poorolajal, Jalal
2016-08-01
Saliva contains alkaline phosphatase (ALP)-a key intracellular enzyme related to destructive processes and cellular damage-and has buffering capacity (BC) against acids due to the presence of bicarbonate and phosphate ions. Smoking may have deleterious effects on the oral environment due to pH changes which can affect ALP activity. This study aimed to evaluate the salivary pH, BC and ALP activity of male smokers and healthy non-smokers. This retrospective cohort study took place between August 2012 and December 2013. A total of 251 healthy male non-smokers and 259 male smokers from Hamadan, Iran, were selected. Unstimulated whole saliva was collected from each participant and pH and BC were determined using a pH meter. Salivary enzymes were measured by spectrophotometric assay. Mean salivary pH (7.42 ± 0.48 and 7.52 ± 0.43, respectively; P = 0.018) and BC (3.41 ± 0.54 and 4.17 ± 0.71; P = 0.001) was significantly lower in smokers compared to non-smokers. Mean ALP levels were 49.58 ± 23.33 IU/L among smokers and 55.11 ± 27.85 IU/L among non-smokers (P = 0.015). Significantly lower pH, BC and ALP levels were observed among smokers in comparison to a healthy control group. These salivary alterations could potentially be utilised as biochemical markers for the evaluation of oral tissue function and side-effects among smokers. Further longitudinal studies are recommended to evaluate the effects of smoking on salivary components.
Saliva characteristics, diet and carioreceptivity in dental students.
Chifor, Ioana; Badea, Iulia; Chifor, Radu; Popa, Dan; Staniste, Liviu; Tarmure, Dragos; Avram, Ramona
2014-01-01
The use of sugar by dental plaque microorganisms leads to acid formation from the bacteria metabolism, which determines a decrease of pH onto teeth surfaces. The value of the critical pH is 5.2-5.5. We aimed to evaluate the capacity of patients to change their diet towards caries prevention after acknowledging the values of saliva parameters (pH, buffer capacity). A group of 52 subjects were clinically examined according to the International Caries Assessment and Detection System protocol. They were required to complete a diet questionnaire and salivary tests were made for the oral mucosa hydration level, pH, buffer capacity, salivary flow rate at rest and upon stimulation. 4 pre-calibrated 6th year students and 2 dentists performed the tests and the ICDAS examination. One week after the tests, the subjects were asked to complete the diet questionnaire again. The studied group consisted of students aged between 23-26 years, randomly selected among 6(th) year students of the Faculty of Dentistry from Cluj-Napoca. The mean DMF-S index was 18.39. Most of the patients (65%) had a DMF-S index between 9 and 21. Just 2.5% had an index of 3, which was the lowest value recorded. 5% of the patients had a DMFS of 35, which was the maximal value recorded. The distribution of DMF-S was normal. 50% of the patients had no active caries. Even though most subjects (19.23%) had a pH within the normal interval, most of them were at the bottom value of the interval (6.8). Most subjects had a pH of 6.4, which is moderately acid. The mean pH was 6.7, therefore, a moderately acid one. The Pearson correlation coefficient between DMFS and pH was 0.255. A mild negative correlation (-0.275) was found between the cariogenic food and buffer capacity. A week later we noticed a statistically significant decrease of cariogenic foods and drinks in students with acid pH and with low buffer capacity. A regular intake of cakes, bonbons and chocolate was reported by subjects who had a high DMF-S value and a low saliva buffer capacity. Only after the patients were aware of their caries risk, did they change their diet towards a non-cariogenic one, even though they had had the theoretical knowledge regarding caries prevention for at least 3 years. We conclude that the use of the chair-side salivary test should be highly recommended for cario-receptive patients.
Sinfiteli, Priscila de Pinto; Coutinho, Thereza Christina Lopes; de Oliveira, Patrícia Regina Almeida; Vasques, Wesley Felisberto; Azevedo, Leandra Matos; Pereira, André Maues Brabo; Tostes, Monica Almeida
2017-01-01
Abstract Casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) complexes are anticariogenic and capable of remineralizing the early stages of enamel lesions. The use of fluoride prevents dental decay and the association of CPP-ACP with fluoride can increase remineralization. Objective: To evaluate the effect of CPP-ACP and CPP-ACPF creams associated with a fluoride dentifrice to prevent enamel demineralization in a pH cyclic model. Material and Methods: Previously selected by surface microhardness (SH) analysis, human enamel blocks (n = 56) were submitted to daily treatment with dentifrice in a pH-cycling model. The enamel blocks were divided into four groups; G1: Crest™ Cavity Protection - Procter & Gamble (1,100 ppmF of NaF); G2: Crest™ +MI Paste (MP) - Recaldent™ GC Corporation Tokyo, Japan); G3: Crest™ + MI Paste Plus (MPP) - Recaldent™ 900 ppm as NaF, GC Corporation Tokyo, Japan), and G4: control, saliva. Specimens were soaked alternatively in a demineralizing solution and in artificial saliva for 5 d. The fluoride dentifrice, with proportion of 1:3 (w/w), was applied three times for 60 s after the remineralization period. The undiluted MP and MPP creams were applied for 3 m/d. After cycling, SH was re-measured and cross section microhardness measurements were taken. Results: The SH values observed for the groups G3 (257±70), G1 (205±70), and G2 (208±84) differed from the G4 group (98±110) (one-way ANOVA and Tukey's post hoc test). There were no differences between the groups G1xG2, G2xG3, and G1xG3 for demineralization inhibition. The percentage of volume mineral showed that, when applied with fluoride dentifrice, MPP was the most effective in preventing enamel demineralization at 50 µ from the outer enamel surface (Kruskal-Wallis and Mann Whitney p<0.05). Conclusion: Fluoride dentifrice associated with CPP-ACPF inhibited subsurface enamel demineralization. PMID:29211281
Vuletic, L; Spalj, S; Rogic, D; Ruzic, L; Alajbeg, I
2013-12-01
The aim of this study was to assess if the consumption of 3 g of a commercially available L-arginine dietary supplement causes a postabsorptive rise in urea concentration or pH of unstimulated saliva in a group of physically active individuals. Salivary urea and pH were determined for 117 participants in a randomized double-blinded placebo-controlled study. Samples were collected by 'spitting' method in fasting conditions. One hour prior to their second visit, participants consumed three tablets of L-arginine or placebo. Urea concentration was significantly lower at second measurement for both the study and control group. The magnitude of the change was not significant between the groups. pH was higher for both groups at second measurement, but only significant for the study group. The magnitude of the change was significant between the groups. Participants who intermittently ingested protein dietary supplements and those with a Body Mass Index (BMI) higher than 25 had significantly higher basal urea concentration. The results of this study did not confirm the hypothesis. Further studies are needed to determine the effects of different doses of L-arginine supplements on the biochemical composition of saliva and the influence of their long-term consumption on the risk of developing dental diseases. © 2013 Australian Dental Association.
Diab, Hafez M; Motlaq, Suha Saeed; Alsharare, Amal; Alshammery, Ashwaq; Alshammery, Nadia; Khawja, Shabnam Gulzar; Shah, Altaf H
2016-10-01
Autism is a neuro-developmental disorder which is manifested as impairment of social interaction, communication and a repetitive behaviour. Autism can obscure dental treatment for the affected patients; furthermore, children with autism commonly have destructive oral habits. The aims of this study were to evaluate the Modified Gingival Index (MGI), Plaque Index (PI), salivary pH and buffering capacity of the saliva among autistic children compared to normal children in Riyadh City that may provide baseline data to enable comparison and future planning of dental services for autistic children. A total of 50 children diagnosed with autism (mean age 8.5 years) were selected from Azzam Autism School, Riyadh City. The control group consisted of 50 non-autistic school children (mean age 8.7 years), gender matched, selected from Outpatient Clinic, Riyadh Colleges of Dentistry and Pharmacy. MGI, PI, salivary pH and salivary buffer capacity tests were done for all participants. The buffering capacity of the stimulated saliva was grouped under 'very low', 'low' and 'normal'. Pearson's Chi square and one way ANOVA were used to find statistical significance if any among the autistic and the normal control group. The results of the study showed that the mean ± standard deviation of MGI, PI and pH of unstimulated resting saliva for autistic group were 1.82 ± 0.65, 1.92 ± 0.35 and 6.8 ± 0.5 respectively. Normal control group had values 1.35 ± 0.85, 1.44 ± 0.43 and 7 ± 0.4 respectively. A statistically significant difference between both groups for all parameters was found. Salivary buffering capacity was found to be normal for the majority among both groups. However, 60% children among the autistic group presented with normal buffering capacity of the stimulated saliva as compared to 70% among the normal control group. However, this difference was not statistically significant (p = 0.544). Children with autism appear to have higher gingival inflammation, poor oral hygiene and a slightly lower salivary pH as compared to healthy control group. Special oral health programmes regarding treatment and maintenance of good oral health should be taken in consideration for autistic children.
Diab, Hafez M; Motlaq, Suha Saeed; Alsharare, Amal; Alshammery, Ashwaq; Alshammery, Nadia; Khawja, Shabnam Gulzar
2016-01-01
Introduction Autism is a neuro-developmental disorder which is manifested as impairment of social interaction, communication and a repetitive behaviour. Autism can obscure dental treatment for the affected patients; furthermore, children with autism commonly have destructive oral habits. Aim The aims of this study were to evaluate the Modified Gingival Index (MGI), Plaque Index (PI), salivary pH and buffering capacity of the saliva among autistic children compared to normal children in Riyadh City that may provide baseline data to enable comparison and future planning of dental services for autistic children. Materials and Methods A total of 50 children diagnosed with autism (mean age 8.5 years) were selected from Azzam Autism School, Riyadh City. The control group consisted of 50 non-autistic school children (mean age 8.7 years), gender matched, selected from Outpatient Clinic, Riyadh Colleges of Dentistry and Pharmacy. MGI, PI, salivary pH and salivary buffer capacity tests were done for all participants. The buffering capacity of the stimulated saliva was grouped under ‘very low’, ‘low’ and ‘normal’. Pearson’s Chi square and one way ANOVA were used to find statistical significance if any among the autistic and the normal control group. Results The results of the study showed that the mean ± standard deviation of MGI, PI and pH of unstimulated resting saliva for autistic group were 1.82 ± 0.65, 1.92 ± 0.35 and 6.8 ± 0.5 respectively. Normal control group had values 1.35 ± 0.85, 1.44 ± 0.43 and 7 ± 0.4 respectively. A statistically significant difference between both groups for all parameters was found. Salivary buffering capacity was found to be normal for the majority among both groups. However, 60% children among the autistic group presented with normal buffering capacity of the stimulated saliva as compared to 70% among the normal control group. However, this difference was not statistically significant (p = 0.544). Conclusion Children with autism appear to have higher gingival inflammation, poor oral hygiene and a slightly lower salivary pH as compared to healthy control group. Special oral health programmes regarding treatment and maintenance of good oral health should be taken in consideration for autistic children. PMID:27891471
Prevention of dentine erosion by brushing with anti-erosive toothpastes.
Aykut-Yetkiner, Arzu; Attin, Thomas; Wiegand, Annette
2014-07-01
This in vitro study aimed to investigate the preventive effect of brushing with anti-erosive toothpastes compared to a conventional fluoride toothpaste on dentine erosion. Bovine dentine specimens (n=12 per subgroup) were eroded in an artificial mouth (6 days, 6×30 s/day) using either citric acid (pH:2.5) or a hydrochloric acid/pepsin solution (pH:1.6), simulating extrinsic or intrinsic erosive conditions, respectively. In between, the specimens were rinsed with artificial saliva. Twice daily, the specimens were brushed for 15 s in an automatic brushing machine at 2.5 N with a conventional fluoride toothpaste slurry (elmex, AmF) or toothpaste slurries with anti-erosive formulations: Apacare (NaF/1% nHAP), Biorepair (ZnCO3-HAP), Chitodent (Chitosan), elmex Erosionsschutz (NaF/AmF/SnCl2/Chitosan), mirasensitive hap (NaF/30% HAP), Sensodyne Proschmelz (NaF/KNO3). Unbrushed specimens served as control. Dentine loss was measured profilometrically and statistically analysed using two-way and one-way ANOVA followed by Scheffe's post hoc tests. RDA-values of all toothpastes were determined, and linear mixed models were applied to analyse the influence of toothpaste abrasivity on dentine wear (p<0.05). Dentine erosion of unbrushed specimens amounted to 5.1±1.0 μm (extrinsic conditions) and 12.9±1.4 μm (intrinsic conditions). All toothpastes significantly reduced dentine erosion by 24-67% (extrinsic conditions) and 21-40% (intrinsic conditions). Biorepair was least effective, while all other toothpastes were not significantly different from each other. Linear mixed models did not show a significant effect of the RDA-value of the respective toothpaste on dentine loss. Toothpastes with anti-erosive formulations reduced dentine erosion, especially under simulated extrinsic erosive conditions, but were not superior to a conventional fluoride toothpaste. Copyright © 2014 Elsevier Ltd. All rights reserved.
Jaffer, F; Finer, Y; Santerre, J P
2002-04-01
Cholesterol esterase (CE) and pseudocholinesterase (PCE) have been reported to degrade commercial and model composite resins containing bisphenylglycidyl dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA) or the latter in combination with urethane modified BisGMA monomer systems. In addition, human saliva has been shown to contain esterase like activities similar to CE and PCE. Hence, it was the aim of the current study to determine to what extent human saliva could degrade two common commercial composite resins (Z250 from 3M Inc. and Spectrum TPH from L.D. Caulk) which contain the above monomer systems. Saliva samples from different volunteers were collected, processed, pooled, and freeze-dried. TEGDMA and BisGMA monomers were incubated with human saliva derived esterase activity (HSDEA) and their respective hydrolysis was monitored using high performance liquid chromatography (HPLC). Both monomers were completely hydrolyzed within 25 h by HSDEA. Photopolymerized composites were incubated with buffer or human saliva (pH 7.0 and 37 C) for 2, 8 and 16 days. The incubation solutions were analyzed using HPLC and mass spectrometry. Surface morphology characterization was carried out using scanning electron microscopy. Upon biodegradation, the Z250 composite yielded higher amounts of BisGMA and TEGDMA related products relative to the TPH composite. However, there were higher amounts of ethoxylated bis-phenol A released from the TPH material. In terms of total mass of products released, human saliva demonstrated a greater ability to degrade Z250. In summary, HSDEA has been shown to contain esterase activities that can readily catalyze the biodegradation of current commercial composite resins.
McKie, Michael J; Andrews, Susan A; Andrews, Robert C
2016-02-15
The presence of endocrine disrupting compounds (EDCs), pharmaceutically active compounds (PhACs) and artificial sweeteners are of concern to water providers because they may be incompletely removed by wastewater treatment processes and they pose an unknown risk to consumers due to long-term consumption of low concentrations of these compounds. This study utilized pilot-scale conventional and biological drinking water treatment processes to assess the removal of nine PhACs and EDCs, and two artificial sweeteners. Conventional treatment (coagulation, flocculation, settling, non-biological dual-media filtration) was compared to biofilters with or without the addition of in-line coagulant (0.2-0.8 mg Al(3+)/L; alum or PACl). A combination of biofiltration, with or without in-line alum, and conventional filtration was able to reduce 7 of the 9 PhACs and EDCs by more than 50% from river water while artificial sweeteners were inconsistently removed by conventional treatment or biofiltration. Increasing doses of PACl from 0 to 0.8 mg/L resulted in average removals of PhACs, EDCs increasing from 39 to 70% and artificial sweeteners removal increasing from ~15% to ~35% in lake water. These results suggest that a combination of biological, chemical and physical treatment can be applied to effectively reduce the concentration of EDCs, PhACs, and artificial sweeteners. Copyright © 2015 Elsevier B.V. All rights reserved.
Metal release from simulated fixed orthodontic appliances.
Hwang, C J; Shin, J S; Cha, J Y
2001-10-01
Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 +/- 0.15, 37 degrees C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 x .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco's copper NiTi and Tomy's Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500 degrees C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows: (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.
The effect of fluoride varnishes on caries lesions: an in vitro investigation.
Al Dehailan, Laila; Martinez-Mier, Esperanza Angeles; Lippert, Frank
2016-09-01
The purpose of this study was to investigate the effect of five commercially available fluoride varnishes (FV) on caries lesions. Ninety bovine enamel specimens were assigned to five varnish groups (n = 18). Early caries lesions were created in the specimens and characterized using Vickers surface microhardness number (VHN). FV was applied to each group of specimens. Immediately afterwards, 7.5 ml of artificial saliva (AS) were pipetted over each group of specimens, collected and renewed every 15 min for 6 h. AS samples were analyzed for fluoride using an ion-specific electrode. Enamel fluoride uptake (EFU) was determined using the acid etch technique. Each group was then subjected to a pH cycling regimen for 5 days after which VHN was determined again. One-way analysis of variance (ANOVA) was used for data analysis. FVs differed in their rehardening capability (highest mean value was for Enamel Pro = 32.3 ± 5.8 and lowest mean value was for Vanish = 18.9 ± 11.3). No significant difference in EFU was found among groups. Total fluoride release over 6 h was in the order of MI Varnish (303 μg/ml) > Enamel Pro (217 μg/ml) > Flor-Opal (153 μg/ml) > PreviDent(84 μg/ml) > Vanish(28 μg/ml). ΔVHN and fluoride release characteristics differ among FV products. These differences may be attributed to the different compositions and physical properties of the tested FV. Fundamental, comparable research on FV and how different formulations affect early caries lesion rehardening, fluoride release into saliva, and uptake by teeth is scarce.
Haznedaroglu, Eda; Mentes, Ali R; Tanboga, Iknur
2012-03-01
The aim of this in vitrostudy was to evaluate the microleakage of a glass-ionomer surface-protector cement (GC Fuji Triage) placed onto the fissure surfaces of extracted human molars prepared using six different treatment procedures. Ninety-six extracted non-carious human molar teeth were divided into five enamel treatment groups: (Gp1) air-abraded (Micadent II, Medidenta); (Gp2) air-abraded and conditioned with 10% polyacrylic acid (GC dentin conditioner); (Gp3) prepared by a bur designed for enameloplasty (#8833 Komet); (Gp4) prepared with a bur and conditioned; (Gp5) conditioned; and (Gp6) no treatment (control). The teeth were then sealed with GC Fuji Triage. The teeth were thermocycled and left in distilled water or artificial saliva for one week, coated twice with nail varnish, and stained in a dye. They were sectioned and scored for microleakage. All groups showed microleakage. Samples that were kept in saliva had better results than those that were kept in distilled water (P<0.05). Samples conditioned before the treatment were also better than non-conditioned groups (P<0.05). In distilled water and artificial saliva, the range of the groups was, from the best, Gp2
Determination of phosphate concentration and pH in artificial tear drops.
de Frutos-Lezaun, M; Martínez-Soroa, I; Ostra Beldarrain, M; Egia Zurutuza, A; Irastorza Larburu, M B; Fernandez Iriarte, A; Bachiller Cacho, M P
2016-08-01
To determine phosphate concentration and pH in artificial tear eye drops commercially available in Spain. A total of 71 examples of artificial tear preparations were identified in a search of Vademecum 2014 and the Spanish Medicines Agency website. In the 24 artificial tear products containing phosphates, quantification of these was performed by ultraviolet molecular absorption spectrophotometry, and the determination of pH was performed using scan image analysis algorithms of pH strips. Of the 71 artificial tears tested, 24 contained phosphate among their excipients in the data sheet, three of which had a concentration level below detection limit (<0.1mM). The mean phosphate concentration was 17.91±23.87mM. The artificial tear sample containing a higher concentration was Colircusi Humectante (87.1mM). Lubricants based on hypromellose showed the highest phosphate concentration (41.59±32.1mM), showing statistically significant differences compared to povidone (P=.0196) and hyaluronate (P=.0067). Statistically significant differences were found between products containing preservatives (32.39±20.91mM), and preservative free ones (8.49±11.98mM) (P=.0498). However, no difference was found between multidose (20.21±26.91mM) and unidose (9.31±14.39mM) samples, or between brand name (15.44±23.3mM) and generic eye drops (20.81mM). The mean pH was 6.93±0.26 (6.2-7.22). No statistical correlation was detected between phosphate concentration and pH (Spearman's Rho -0.1089 and P=.6125). A total of 24 (33.8%) of the 71 artificial tears contained phosphate. We believe identifying the phosphate concentration of artificial tears is useful information in order to avoid complications in high-risk patients. Copyright © 2016. Published by Elsevier España, S.L.U.
2011-01-01
Background Hyposalivation is caused by various syndromes, diabetes, drugs, inflammation, infection, or radiotherapy of the salivary glands. Patients with hyposalivation often show an increased caries incidence. Moreover, hyposalivation is frequently accompanied by oral discomfort and impaired oral functions, and saliva substitutes are widely used to alleviate oral symptoms. However, preference of saliva substitutes due to taste, handling, and relief of oral symptoms has been discussed controversially. Some of the marketed products have shown demineralizing effects on dental hard tissues in vitro. This demineralizing potential is attributed to the undersaturation with respect to calcium phosphates. Therefore, it is important to modify the mineralizing potential of saliva substitutes to prevent carious lesions. Thus, the aim of the present study was to evaluate the effects of a possible remineralizing saliva substitute (SN; modified Saliva natura) compared to a demineralizing one (G; Glandosane) on mineral parameters of sound bovine dentin and enamel as well as on artificially demineralized enamel specimens in situ. Moreover, oral well-being after use of each saliva substitute was recorded. Methods/Design Using a randomized, double-blind, crossover, phase II/III in situ trial, volunteers with hyposalivation utilize removable dentures containing bovine specimens during the experimental period. The volunteers are divided into two groups, and are required to apply both saliva substitutes for seven weeks each. After both test periods, differences in mineral loss and lesion depth between values before and after exposure are evaluated based on microradiographs. The oral well-being of the volunteers before and after therapy is determined using questionnaires. With respect to the microradiographic analysis, equal mineral losses and lesion depths of enamel and dentin specimens during treatment with SN and G, and no differences in patients' experienced oral comfort after SN compared to G usage are expected (H0). Discussion Up to now, 14 patients have been included in the study, and no reasons for early termination of the trial have been identified. The design seems suitable for determining the effects of saliva substitutes on dental hard tissues in situ, and should provide detailed information on the oral well-being after use of different saliva substitutes in patients with hyposalivation. Trial registration ClinicalTrials.gov ID. NCT01165970 PMID:21477333
Foglio-Bonda, P L; Migliario, M; Rocchetti, V; Pattarino, F; Foglio-Bonda, A
2013-09-01
To analyse pH and flow rate (FR) of unstimulated whole saliva (UWS), detecting their possible correlations both among themselves and with body profile; in addition to identify daily, annually and gender differences. Eighty-one (47 ♀; 34 ♂) healthy young adults (mean age 22.7±4.09 years old) were enrolled. Saliva was sampled using spitting method. The data were statistically analysed using Pearson's coefficient, ANOVA or Kruskal-Wallis test, Student's t test or the Wilcoxon-Mann-Whitney test. The mean UWS/FR was 0.643 ml/min (range 0.164-1.656 ml/min; percentile 25 = 0.400 ml/min; percentile 50 = 0.643 ml/min, percentile 75 = 0.832 ml/min; median = 0.590 ml/min) and no significant differences were found in gender. The mean UWS/pH was 6.95 (range 6.06-7.91, S.D. 0.28, RSD % 4.08): pH was higher in males (7.02) than females (6.92; p = 0.009). The UWS/FR increased almost steadily during the day: from 0.593 ml/min at 9:00 to 0.669 ml/min at 17:00 (p = 0.04), the greatest increase was found between 9:00 and 11:00. Through the seasons the UWS/FR decreased from summer to spring with a difference of 0.048 ml/min (p < 0.05). The UWS/pH showed a slight increase between 9:00 and 17:00 (p < 0.05). There were little differences in UWS/pH among the seasons (max. 0.09; p < 0.05). Only a significant correlation between UWS/FR and pH was found (R = 0.20; p = 0.008). We did not find correlations between body profile vs UWS/FR or pH. UWS/FR varies more widely than UWS/pH: maintaining a proper acid/base balance is an essential factor for the homeostasis of the oral cavity and probably this would explain the reason for the lack of the variables evaluated influencing UWS/pH.
Salivary pH and buffering capacity in early and late human immunodeficiency virus infection.
Hegde, Mithra N; Malhotra, Amit; Hegde, Nidarsh D
2013-11-01
Human immunodeficiency virus (HIV) causes severe immunosuppression due to progressive decrease in the CD4 T lymphocyte cells during the course of the disease and this affects all the body systems including glandular secretions. A number of lesions affecting the salivary glands have been noted in HIV infection. The objective of this study was to evaluate the salivary pH and the buffering capacity in HIV positive individuals and comparing it with the HIV negative healthy individuals. The study was carried out on 200 HIV positive subjects aged 20-40 years, divided into two groups on the basis of CD4 count and 100 HIV negative healthy individuals as control group. Both unstimulated and stimulated saliva were collected and the pH and buffering capacity ascertained using the saliva check kit. (GC Asia Dental Pvt. Ltd., Singapore, 508724). All the three groups were compared using the ANOVA and it was found there was highly significant decrease in pH and buffering capacity with increase in immunosuppression. The intergroup comparison was carried out using the Tukey honestly significant difference (HSD) and the Chi square test. Group 1; CD4 count <200 and Group 2, CD4 count >200 showed a significant decrease in unstimulated salivary flow, stimulated salivary flow, and pH in comparison to HIV negative individuals; however, change in buffering capacity in Group 2 was not significant. There is a decrease in pH and buffering capacity in HIV infected patients. This decrease may be one of the factors responsible for increased caries in HIV infected population.
USDA-ARS?s Scientific Manuscript database
Salivary proteins of Culicoides biting midges are thought to play a key role in the induction of summer eczema (SE), a seasonal recurrent allergic dermatitis in horses. The present study describes the identification of a candidate allergen in artificially collected saliva of the North American speci...
The effect of different beverages on surface hardness of nanohybrid resin composite and giomer.
Tanthanuch, Saijai; Kukiattrakoon, Boonlert; Siriporananon, Chantima; Ornprasert, Nawanda; Mettasitthikorn, Wathu; Likhitpreeda, Salinla; Waewsanga, Sulawan
2014-05-01
To investigate the effects of five beverages (apple cider, orange juice, Coca-Cola, coffee, and beer) on microhardness and surface characteristic changes of nanohybrid resin composite and giomer. Ninety-three specimens of each resin composite and giomer were prepared. Before immersion, baseline data of Vicker's microhardness was recorded and surface characteristics were examined using scanning electron microscopy (SEM). Five groups of discs (n = 18) were alternately immersed in 25 mL of each beverage for 5 s and in 25 mL of artificial saliva for 5 s for 10 cycles. Specimens were then stored in artificial saliva for 24 h. This process was repeated for 28 days. After immersion, specimens were evaluated and data were analyzed by two-way repeated analysis of variance (ANOVA), Tukey's honestly significant difference (HSD), and a t-test (α = 0.05). Microhardness of all groups significantly decreased after being immersed in the tested beverages (P < 0.05). SEM photomicrographs presented surface degradation of all groups. The effect of these beverages on the surface of both restorative materials also depended upon the exposure time and chemical composition of the restorative materials and beverages.
The effect of different beverages on surface hardness of nanohybrid resin composite and giomer
Tanthanuch, Saijai; Kukiattrakoon, Boonlert; Siriporananon, Chantima; Ornprasert, Nawanda; Mettasitthikorn, Wathu; Likhitpreeda, Salinla; Waewsanga, Sulawan
2014-01-01
Aims: To investigate the effects of five beverages (apple cider, orange juice, Coca-Cola, coffee, and beer) on microhardness and surface characteristic changes of nanohybrid resin composite and giomer. Materials and Methods: Ninety-three specimens of each resin composite and giomer were prepared. Before immersion, baseline data of Vicker's microhardness was recorded and surface characteristics were examined using scanning electron microscopy (SEM). Five groups of discs (n = 18) were alternately immersed in 25 mL of each beverage for 5 s and in 25 mL of artificial saliva for 5 s for 10 cycles. Specimens were then stored in artificial saliva for 24 h. This process was repeated for 28 days. After immersion, specimens were evaluated and data were analyzed by two-way repeated analysis of variance (ANOVA), Tukey's honestly significant difference (HSD), and a t-test (α = 0.05). Results: Microhardness of all groups significantly decreased after being immersed in the tested beverages (P < 0.05). SEM photomicrographs presented surface degradation of all groups. Conclusions: The effect of these beverages on the surface of both restorative materials also depended upon the exposure time and chemical composition of the restorative materials and beverages. PMID:24944451
Effect of Ag Addition on the Electrochemical Performance of Cu10Al in Artificial Saliva
Salgado-Salgado, R. J.; Sotelo-Mazon, O.; Rodriguez-Diaz, R. A.; Salinas-Solano, G.
2016-01-01
In this work we proposed to evaluate the corrosion resistance of four different alloys by electrochemical techniques, a binary alloy Cu10Al, and three ternary alloys Cu10Al-xAg (x = 5, 10, and 15 wt.%) to be used like biomaterials in dental application. Biomaterials proposed were tested in artificial saliva at 37°C for 48 h. In addition, pure metals Cu, Al, Ag, and Ti as reference materials were evaluated. In general the short time tests indicated that the Ag addition increases the corrosion resistance and reduces the extent of localized attack of the binary alloy. Moreover, tests for 48 hours showed that the Ag addition increases the stability of the passive layer, thereby reducing the corrosion rate of the binary alloy. SEM analysis showed that Cu10Al alloy was preferably corroded by grain boundaries, and the Ag addition modified the form of attack of the binary alloy. Cu-rich phases reacted with SCN− anions forming a film of CuSCN, and the Ag-rich phase is prone to react with SCN− anions forming AgSCN. Thus, binary and ternary alloys are susceptible to tarnish in the presence of thiocyanate ions. PMID:27660601
Effect of endurance training on dental erosion, caries, and saliva.
Frese, C; Frese, F; Kuhlmann, S; Saure, D; Reljic, D; Staehle, H J; Wolff, D
2015-06-01
The aim of this investigation was to give insights into the impact of endurance training on oral health, with regard to tooth erosion, caries, and salivary parameters. The study included 35 triathletes and 35 non-exercising controls. The clinical investigation comprised oral examination, assessment of oral status with special regard to caries and erosion, saliva testing during inactivity, and a self-administered questionnaire about eating, drinking, and oral hygiene behavior. In addition, athletes were asked about their training habits and intake of beverages and sports nutrition. For saliva assessment during exercise, a subsample of n = 15 athletes volunteered in an incremental running field test (IRFT). Athletes showed an increased risk for dental erosion (P = 0.001). No differences were observed with regard to caries prevalence and salivary parameters measured during inactivity between athletes and controls. Among athletes, a significant correlation was found between caries prevalence and the cumulative weekly training time (r = 0.347, P = 0.04). In athletes after IRFT and at maximum workload, saliva flow rates decreased (P = 0.001 stimulated; P = 0.01 unstimulated) and saliva pH increased significantly (P = 0.003). Higher risk for dental erosions, exercise-dependent caries risk, and load-dependent changes in saliva parameters point out the need for risk-adapted preventive dental concepts in the field of sports dentistry. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Force decay and deformation of orthodontic elastomeric ligatures.
Taloumis, L J; Smith, T M; Hondrum, S O; Lorton, L
1997-01-01
This study evaluated commercially available molded gray elastomeric ligatures from seven companies for force decay, dimensional change, and the relationship between ligature dimension and force. The initial wall thickness, inside diameter, outside diameter, and force levels of each ligature were measured. Three of four test groups of ligatures were stretched over stainless steel dowels with a circumference approximating that of a large orthodontic twin bracket. Test group 1 was kept at room temperature and humidity for 28 days and test group 2 in a synthetic saliva bath at 37 degrees C, pH 6.84 for 28 days. The residual forces and dimensional changes were measured. The third test group was placed in a synthetic saliva bath at 37 degrees C, pH 6.84, and force levels recorded at initial, 24 hours, 7 days, 14 days, and 28 days. The fourth test group of unstretched samples was placed in a synthetic saliva bath at 37 degrees C, pH 6.84 for 28 days to evaluate dimensional changes due solely to moisture sorption. The results for stretched samples in a simulated oral environment revealed the following: (1) Moisture and heat had a pronounced effect on force decay and permanent deformation, (2) a positive correlation existed between the wall thickness and force, (3) a negative correlation existed between the inside diameter and force, (4) a weak correlation existed between outside diameter and force, (5) the greatest force loss occurred in the first 24 hours and the decay pattern was similar for all ligatures tested, and (6) unstretched ligatures absorbed moisture in the range of 0.060% to 3.15%. The ligatures tested appear to be suitable for use during initial aligning and leveling. However, the rapid force loss and permanent deformation of these products may preclude their use for rotational and torque corrections.
Ho, Jessica; Firmalino, Miracle Vania; Anbarani, Afarin Golabgir; Takesh, Thair; Epstein, Joel; Wilder-Smith, Petra
2017-02-01
The goal of this study was to identify the in vivo effects in patients with hyposalivation of a novel slowly dissolving adhering test disc upon on enamel remineralization, oral biofilm, salivary production, pH and buffering, gingival health, and on self-evaluation of oral well-being. Five subjects with xerostomia wore custom made retainers carrying 5 demineralized enamel chips for periods of 1 week each. In 1 study arm, subjects used the test agent plus oral hygiene self-care; in the other they used oral hygiene self-care only, with a 1 week washout in between arms. The treatment sequence was randomized. Before and after each study arm Plaque Index (PI), Gingival Index (GI) and Sulcus Bleeding Index (mSBI) were recorded. Clinical plaque staining was quantified using digital image analysis. Saliva production, pH and buffering capacity were recorded. Subjects completed a self-evaluation questionnaire for oral comfort. Enamel samples underwent standardized Knoop microhardness testing to quantify mineralization status. Plaque presence and clinical Plaque Indices decreased significantly with test agent use (p<0.05). Five-minute saliva production almost doubled 10 and 40 minutes after oral test disc insertion (significant, p<0.05). Salivary pH buffering improved in 4/5 subjects with disc use. All demineralized tooth samples re-hardened intraorally (p>0.05). The discs favorably impacted eating problems and dental sensitivity. Subjects were positive about disc flavor and mouth feel. Using established in vivo techniques, the effects of a novel product in xerostomic patients were evaluated and quantified. The adhering disc facilitated eating, reduced dental sensitivity, improved saliva production and buffering capacity, reduced plaque, and alleviated xerostomia symptoms. Xerostomia management is challenging. A novel dry mouth disc was effective in alleviating dry mouth symptoms.
Pandey, Pallavi; Reddy, N Venugopal; Rao, V Arun Prasad; Saxena, Aditya; Chaudhary, C P
2015-03-01
The aim of the study was to evaluate salivary flow rate, pH, buffering capacity, calcium, total protein content and total antioxidant capacity in relation to dental caries, age and gender. The study population consisted of 120 healthy children aged 7-15 years that was further divided into two groups: 7-10 years and 11-15 years. In this 60 children with DMFS/dfs = 0 and 60 children with DMFS/dfs ≥5 were included. The subjects were divided into two groups; Group A: Children with DMFS/dfs = 0 (caries-free) Group B: Children with DMFS/dfs ≥5 (caries active). Unstimulated saliva samples were collected from all groups. Flow rates were determined, and samples analyzed for pH, buffer capacity, calcium, total protein and total antioxidant status. Salivary antioxidant activity is measured with spectrophotometer by an adaptation of 2,2'-azino-di-(3-ethylbenzthiazoline-6-sulphonate) assays. The mean difference of the two groups; caries-free and caries active were proved to be statistically significant (P < 0.05) for salivary calcium, total protein and total antioxidant level for both the sexes in the age group 7-10 years and for the age 11-15 years the mean difference of the two groups were proved to be statistically significant (P < 0.05) for salivary calcium level for both the sexes. Salivary total protein and total antioxidant level were proved to be statistically significant for male children only. In general, total protein and total antioxidants in saliva were increased with caries activity. Calcium content of saliva was found to be more in caries-free group and increased with age.
Chromium release from new stainless steel, recycled and nickel-free orthodontic brackets.
Sfondrini, Maria Francesca; Cacciafesta, Vittorio; Maffia, Elena; Massironi, Sarah; Scribante, Andrea; Alberti, Giancarla; Biesuz, Raffaela; Klersy, Catherine
2009-03-01
To test the hypothesis that there is no difference in the amounts of chromium released from new stainless steel brackets, recycled stainless steel brackets, and nickel-free (Ni-free) orthodontic brackets. This in vitro study was performed using a classic batch procedure by immersion of the samples in artificial saliva at various acidities (pH 4.2, 6.5, and 7.6) over an extended time interval (t(1) = 0.25 h, t(2) = 1 h, t(3) = 24 h, t(4) = 48 h, t(5) = 120 h). The amount of chromium release was determined using an atomic absorption spectrophotometer and an inductively coupled plasma atomic emission spectrometer. Statistical analysis included a linear regression model for repeated measures, with calculation of Huber-White robust standard errors to account for intrabracket correlation of data. For post hoc comparisons the Bonferroni correction was applied. The greatest amount of chromium was released from new stainless steel brackets (0.52 +/- 1.083 microg/g), whereas the recycled brackets released 0.27 +/- 0.38 microg/g. The smallest release was measured with Ni-free brackets (0.21 +/- 0.51 microg/g). The difference between recycled brackets and Ni-free brackets was not statistically significant (P = .13). For all brackets, the greatest release (P = .000) was measured at pH 4.2, and a significant increase was reported between all time intervals (P < .002). The hypothesis is rejected, but the amount of chromium released in all test solutions was well below the daily dietary intake level.
Hohensinn, Barbara; Haselgrübler, Renate; Müller, Ulrike; Stadlbauer, Verena; Lanzerstorfer, Peter; Lirk, Gerald; Höglinger, Otmar; Weghuber, Julian
2016-11-30
Dietary inorganic nitrate (NO 3 - ) and its reduced forms nitrite (NO 2 - ) and nitric oxide (NO), respectively, are of critical importance for host defense in the oral cavity. High concentrations of salivary nitrate are linked to a lower prevalence of caries due to growth inhibition of cariogenic bacteria. In-vitro studies suggest that the formation of antimicrobial NO results in an increase of the pH preventing erosion of tooth enamel. The purpose of this study was to prove this effect in-vivo. In a randomized clinical study with 46 subjects we investigated whether NO 3 - rich beetroot juice exhibits a protective effect against caries by an increase of salivary pH. Our results show that, in comparison to a placebo group, consumption of beetroot juice that contains 4000 mg/L NO 3 - results in elevated levels of salivary NO 2 - , nitrite NO 3 - , and NO. Furthermore, we determined an increase of the mean pH of saliva from 7.0 to 7.5, confirming the anti-cariogenic effect of the used NO 3 - -rich beetroot juice. Taken together, we have found that NO 3 - -rich beetroot juice holds potential effects against dental caries by preventing acidification of human saliva. C-87-15 (Ethics Commissions of Upper Austria). Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Bernardi, Maria José; Reis, Alessandra; Loguercio, Alessandro Dourado; Kehrig, Ruth; Leite, Mariana Ferreira; Nicolau, José
2007-01-01
This study measured the flow rate, pH and buffering capacity of saliva from well- and poorly metabolically controlled Type 2 diabetic patients in three cities of the southern part of Brazil, compared with healthy individuals from the same cities. Whole saliva was collected by mechanical stimulation and buffering capacity and glucose level were measured. Blood was collected after 12 hours fasting and glucose and glycosylated haemoglobin concentrations were determined. The data were analysed by one-way ANOVA and Student-Newman-Keuls (alpha= 0.05). The flow rate was lower in the Type 2 diabetic patients, regardless of whether they were well or poorly metabolically controlled, compared with healthy individuals (p < 0.05). Salivary glucose concentration was higher in both diabetic patient groups, i.e. well and poorly metabolically controlled, than in the control (p < 0.05). The metabolic control of hyperglycaemia was not sufficient to improve the salivary flow rate or the salivary glucose concentration.
Lee, Sang-Bae; González-Cabezas, Carlos; Kim, Kwang-Mahn; Kim, Kyoung-Nam; Kuroda, Kenichi
2015-08-10
This study reports a synthetic polymer functionalized with catechol groups as dental adhesives. We hypothesize that a catechol-functionalized polymer functions as a dental adhesive for wet dentin surfaces, potentially eliminating the complications associated with saliva contamination. We prepared a random copolymer containing catechol and methoxyethyl groups in the side chains. The mechanical and adhesive properties of the polymer to dentin surface in the presence of water and salivary components were determined. It was found that the new polymer combined with an Fe(3+) additive improved bond strength of a commercial dental adhesive to artificial saliva contaminated dentin surface as compared to a control sample without the polymer. Histological analysis of the bonding structures showed no leakage pattern, probably due to the formation of Fe-catechol complexes, which reinforce the bonding structures. Cytotoxicity test showed that the polymers did not inhibit human gingival fibroblast cells proliferation. Results from this study suggest a potential to reduce failure of dental restorations due to saliva contamination using catechol-functionalized polymers as dental adhesives.
2015-01-01
This study reports a synthetic polymer functionalized with catechol groups as dental adhesives. We hypothesize that a catechol-functionalized polymer functions as a dental adhesive for wet dentin surfaces, potentially eliminating the complications associated with saliva contamination. We prepared a random copolymer containing catechol and methoxyethyl groups in the side chains. The mechanical and adhesive properties of the polymer to dentin surface in the presence of water and salivary components were determined. It was found that the new polymer combined with an Fe3+ additive improved bond strength of a commercial dental adhesive to artificial saliva contaminated dentin surface as compared to a control sample without the polymer. Histological analysis of the bonding structures showed no leakage pattern, probably due to the formation of Fe–catechol complexes, which reinforce the bonding structures. Cytotoxicity test showed that the polymers did not inhibit human gingival fibroblast cells proliferation. Results from this study suggest a potential to reduce failure of dental restorations due to saliva contamination using catechol-functionalized polymers as dental adhesives. PMID:26176305
Pitta, João; Branco, Teresa C; Portugal, Jaime
2018-05-01
Saliva contamination has been shown to decrease bonding to zirconia. Adopting a less contamination-sensitive cement system may be an alternative to decontamination. The purpose of this in vitro study was to assess the ability of different primer/cement systems to promote a durable bond to zirconia after saliva contamination. Zirconia blocks (Lava Plus) (N=320) were airborne-particle abraded (50 μm Al 2 O 3 ) and divided into 32 experimental groups (n=10) according to the variables in the study: saliva contamination; primer/cement system (Panavia SA [PSA]; RelyX Unicem 2 [RU2]; Bifix SE [BSE]; Panavia F2.0 [PF2]; Scotchbond Universal + RelyX Ultimate [SBU+RXU]; Futurabond M+ + Bifix QM [FBM+BQM]; All-Bond Universal + Duo-link [ABU+DL]; Z-Prime Plus + Duo-link [ZPP+DL]; and aging period (72 hours; 30 days with 10 000 thermocycles at 5°C to 55°C). After half of the blocks had been contaminated with fresh human saliva for 10 minutes, rinsed with water, and air-dried, each primer/cement was applied. Polymerized composite resin disks were then placed over the cement, and the resin cement was light-polymerized for 20 seconds each at 2 opposite margins. After the aging time, the specimens were tested in shear (1 mm/min). The failure mode was classified as adhesive, cohesive, or mixed. Statistical analysis of the shear bond strength (SBS) data was performed with ANOVA followed by Tukey honest significant difference post hoc tests. Chi-square tests were used to analyze the failure mode data (α=.05). The mean SBS ranged between 4.2 and 34.5 MPa. Shear bond strength was influenced (P<.001) by all the factors studied (cement system, saliva contamination, aging time). SBU+RXU and FBM+BQM showed a higher mean SBS than those of the other experimental groups (P<.05) and were the only groups not affected by saliva contamination (P>.05). Failure was predominantly classified as adhesive. In general, saliva contamination and aging decreased bonding efficacy. Two systems, combining an application of a universal adhesive and a resin cement (SBU+RXU and FBM+BQM) were not affected by saliva contamination. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
[Stress-corrosion test of TIG welded CP-Ti].
Li, H; Wang, Y; Zhou, Z; Meng, X; Liang, Q; Zhang, X; Zhao, Y
2000-12-01
In this study TIG (Tungsten Inert Gas) welded CP-Ti were subjected to stress-corrosion test under 261 MPa in artificial saliva of 37 degrees C for 3 months. No significant difference was noted on mechanical test (P > 0.05). No color-changed and no micro-crack on the sample's surface yet. These results indicate that TIG welded CP-Ti offers excellent resistance to stress corrosion.
Effect of bleaching agents and soft drink on titanium surface topography.
Faverani, Leonardo P; Barão, Valentim A R; Ramalho-Ferreira, Gabriel; Ferreira, Mayara B; Garcia-Júnior, Idelmo R; Assunção, Wirley G
2014-01-01
The effects of carbamide peroxide, hydrogen peroxide and cola soft drink on the topographic modifications of commercially-pure titanium (CP-Ti) and Ti-6Al-4V were investigated. Ti discs were divided into 18 groups (n = 4) based on the solution treatment and Ti type. Specimens were immersed in 3 mL of each solution for 4 h per day (for the remaining 20 h, discs were left dry or immersed in artificial saliva) for 15 days. For control, specimens were immersed in only artificial saliva. Ti surfaces were examined using scanning electron (SEM) and atomic force (AFM) microscopes and their surface roughness (in µm) and surface chemical modifications were investigated. Data were analyzed by ANOVA and Tukey's test (α = 0.05). Groups immersed in 35% hydrogen peroxide showed the highest roughness (Ra) (171.65 ± 4.04 for CP-Ti and 145.91 ± 14.71 for Ti-6Al-4V) (p < 0.05), followed by groups treated with carbamide peroxide 16% (110.91 ± 0.8 for CP-Ti and 49.28 ± 0.36 for Ti-6Al-4V) and 35% (65.67 ± 1.6 for CP-Ti and 53.87 ± 1.98 for Ti-6Al-4V); treatment with artificial saliva did not affect the results. These values were statistically superior to those observed prior to the treatment and to those of the control group (31.0 ± 0.99 for CP-Ti and 29.95 ± 0.58 for Ti-6Al-4V). Cola soft drink did not alter the surface roughness of either Ti type (p > 0.05). SEM and AFM revealed dramatic changes in the specimens surfaces immersed in the 35% hydrogen peroxide, mainly for CP-Ti. No detectable chemical modifications on the Ti surface were observed. Bleaching agents promoted significant changes in Ti topography, which could affect the longevity of implants treatments. Copyright © 2013 Wiley Periodicals, Inc.
Galbraith, David A.; Grozinger, Christina M.; Felton, Gary W.
2017-01-01
Generalist herbivores feed on a wide array of plants and need to adapt to varying host qualities and defenses. One of the first insect derived secretions to come in contact with the plant is the saliva. Insect saliva is potentially involved in both the pre-digestion of the host plant as well as induction/suppression of plant defenses, yet how the salivary glands respond to changes in host plant at the transcriptional level is largely unknown. The objective of this study was to determine how the labial salivary gland transcriptome varies according to the host plant on which the insect is feeding. In order to determine this, cabbage looper (Trichoplusia ni) larvae were reared on cabbage, tomato, and pinto bean artificial diet. Labial glands were dissected from fifth instar larvae and used to extract RNA for RNASeq analysis. Assembly of the resulting sequencing reads resulted in a transcriptome library for T. ni salivary glands consisting of 14,037 expressed genes. Feeding on different host plant diets resulted in substantial remodeling of the gland transcriptomes, with 4,501 transcripts significantly differentially expressed across the three treatment groups. Gene expression profiles were most similar between cabbage and artificial diet, which corresponded to the two diets on which larvae perform best. Expression of several transcripts involved in detoxification processes were differentially expressed, and transcripts involved in the spliceosome pathway were significantly downregulated in tomato-reared larvae. Overall, this study demonstrates that the transcriptomes of the salivary glands of the cabbage looper are strongly responsive to diet. It also provides a foundation for future functional studies that can help us understand the role of saliva of chewing insects in plant-herbivore interactions. PMID:28792546
Soares, Luís Eduardo Silva; De Carvalho Filho, Antonio Carlos Belfort
2015-03-01
The effects of fluoride treatment on bovine enamel subjected to acid erosion were studied by roughness (Ra) measurements, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and microenergy-dispersive X-ray fluorescence spectrometry (μ-EDXRF). Enamel samples (63) were divided into nine groups (n = 7): artificial saliva (AS), Pepsi Twist(®) (PT), orange juice (OJ), Duraphat(®) + Pepsi Twist(®) (DPH/PT), Duraphat(®) + orange juice (DPH/OJ), Duofluorid(®) + Pepsi Twist(®) (DUO/PT), Duofluorid(®) + orange juice (DUO/OJ), fluoride gel + Pepsi Twist(®) (FG/PT), and fluoride gel + orange juice (FG/OJ). Fluoride was applied and the samples were submitted to six cycles (demineralization: Pepsi Twist(®) or orange juice, 10 min; remineralization: saliva, 1 h). The enamel surface in depth was exposed and 63 line-scan maps were performed. The elemental analysis by EDS revealed that only fluoride treated groups had any detectable fluorine after erosion cycles (DPH/PT: 3.50 wt%; DPH/OJ: 3.37 wt%; DUO/PT: 2.69 wt%; DUO/OJ: 3.54 wt%; FG/PT: 2.17 wt%; FG/OJ: 2.77 wt%). PT treatment resulted in significantly higher Ra values than the artificial saliva (P < 0.001). Scanning electron microscopy (SEM) analysis of fluoride protected enamel showed areas with some globular structures or a residual layer of varnish. The enamel thickness was significantly lower in PT (0.63 ± 0.087 mm) than in DPH/PT (0.87 ± 0.16 mm) and DUO/PT (0.92 ± 0.14 mm) groups (P < 0.01). Fluoride treatments protected enamel without Ra increase and loss of enamel tissue. © 2015 Wiley Periodicals, Inc.
Marangoni-Lopes, L; Rodrigues, L P; Mendonça, R H; Nobre-Dos Santos, M
2016-12-01
We aimed to perform a longitudinal investigation of the effects of radiotherapy on salivary flow rate, pH, buffering capacity, and protein composition of saliva and on the quality of life of children with Hodgkin disease. Ten children (6-16-year-old) with Hodgkin disease and 10 matched healthy children were investigated. Stimulated and non-stimulated saliva samples were collected at baseline, after 1080 and 2160cGy of radiation, and 1, 2, and 3 months post-radiotherapy. The salivary flow rate was expressed as mL/min. Buffer capacity was determined by titration. Amylase activity, immunoglobulin A, mucin, and lactoferrin concentrations were determined by ELISA. Quality of life was assessed by Quality of Life - Head and Neck module 35 questionnaire. We found that radiotherapy caused hyposalivation at 1080cGy and 1 month after radiotherapy and reduced buffering capacity at 2160cGy. Mucin concentration and amylase activity in non-stimulated saliva increased 1 month after radiotherapy. Lactoferrin concentration increased during and after radiotherapy. Immunoglobulin A concentration increased at 1080cGy, 1 and 2 months, for non-stimulated saliva and at 2160cGy and 1 month for stimulated saliva. Children reported more pain after radiotherapy and more xerostomia during radiotherapy. We concluded that the radiotherapy protocol affected the children's salivary properties and children's quality of life. Copyright © 2016 Elsevier Ltd. All rights reserved.
Biocorrosion Evaluation on a Zr-Cu-Ag-Ti Metallic Glass
NASA Astrophysics Data System (ADS)
Kumar, Shresh; Anwar, Rebin; Ryu, Wookha; Park, E. S.; Vincent, S.
2018-04-01
Metallic glasses are in high demand for fabrication of variety of innovative products, in particular surgical and biomedical tools and devices owing to its excellent biocompatible properties. In the present investigation, a novel Zr39.5Cu50.5Ag4Ti6 metallic glass composition was synthesized using melt spinning technique. Potentiodynamic polarization studies were conducted to investigate bio-corrosion behaviour of Zr39.5Cu50.5Ag4Ti6 metallic glass. The test were conducted in various simulated artificial body conditions such as artificial saliva solution, phosphate-buffered saline solution, artificial blood plasma solution, and Hank’s balanced saline solution. The bio-corrosion results of metallic glass were compared with traditional biomaterials. The study aims to provide bio-compatible properties of Zr39.5Cu50.5Ag4Ti6 metallic glass.
The influence of fluoride varnish on the attrition of dentine.
Li, H; Watson, T F; Sherriff, M; Curtis, R; Bartlett, D W
2007-01-01
Previous investigations have shown the potential for fluoride to be protective in an abrasion/erosion laboratory model. The aim of this study was to investigate the effect of high concentrations of fluoride delivered in a varnish on attrition of dentine. Fifteen caries-free, intact lower third molar teeth were sectioned and the enamel removed by a water-cooled diamond disc. Polished dentine surfaces were divided into 8 areas, 4 of which were randomly covered with a high-concentration fluoride varnish for 24 h. The samples were subjected to 5,000 cycles of attrition bathed under artificial saliva. Microhardness testing adjacent to the wear scars showed no statistical difference between the fluoride-treated (71.42 KHN, SD 10.52) and control surfaces (72.66 KHN, SD 9.69). The volume of the wear scar was statistically greater for the fluoride-treated surface at 9.6 microm(3) (SD 4.92) and 8.13 microm(3) (SD 5.54) for the control areas (p = 0.029). The low pH of the fluoride varnish appears to have increased the amount of wear from attrition in this laboratory study. Copyright 2007 S. Karger AG, Basel.
An experiment on the attrition of acid demineralized dentine in vitro.
Li, H; Liu, M C; Deng, M; Moazzez, R; Bartlett, D W
2011-03-01
A laboratory investigation was designed to test the hypothesis that acids increase the rate of wear caused by attrition on dentine. Dentine sections from 10 teeth were polished, cleaned in an ultrasonic bath and divided into 8 equally sized areas. The occlusal tip of a tooth, placed vertically in a wear machine and loaded at 150 N, was moved against each dentine section for 5000 return strokes with artificial saliva acting as a lubricant. Each dentine section was divided into 8 sections and half randomly immersed in a 1% citric acid solution (pH 2.3) for 20 minutes. The wear regime produced 8 wear scars in total per dentine sample. The volume of each wear scar was measured using a contacting digitizing profilometer. A total of 80 wear scars were produced with 40 treated with acid and 40 acting as controls. The mean for wear volume of the dentine scars with acid was 4.84 μm(3) (1.38) and for the non-acid surface 2.95 μm(3) (0.86). This difference was statistically significant (p < 0.05). These results support the hypothesis that acids increase the rate of wear caused by attrition on dentine. © 2011 Australian Dental Association.
A PEROXIDASE-MEDIATED, STREPTOCOCCUS MITIS-DEPENDENT ANTIMICROBIAL SYSTEM IN SALIVA
Hamon, Charles B.; Klebanoff, Seymour J.
1973-01-01
H2O2 formation by Streptococcus mitis was measured by the catalase-dependent conversion of [14C]formate to 14CO2 ; it was optimal at pH 6.0–6.5 and required glucose. The H2O2 formed by S. mitis could be employed as a component of an antimicrobial system that also included lactoperoxidase (LPO) and either iodide or thiocyanate ions in the concentrations present in saliva. The antimicrobial effect of the LPO-iodide-S. mitis system was measured by the decrease in the viable cell count of the target organisms (Escherichia coli, Staphylococcus aureus, Candida tropicalis). The antimicrobial effect of the LPO-thiocyanate-S. mitis system was measured by the decrease in the rate of growth or the rate of uptake of [14C]valine by the target organisms (E. coli, S. aureus). Mixed or parotid saliva could replace LPO and thiocyanate ions in the S. mitis-dependent inhibition of bacterial growth and valine uptake. The presence in saliva of a peroxidase-mediated, antimicrobial system dependent on microbial metabolism for H2O2 and its role as a natural host defense mechanism are considered. PMID:4685704
Morou-Bermudez, E; Elias-Boneta, A; Billings, RJ; Burne, RA; Garcia-Rivas, V; Brignoni-Nazario, V; Suarez-Perez, E
2011-01-01
Bacterial urease activity in dental plaque and in saliva generates ammonia, which can increase the plaque pH and can protect acid-sensitive oral bacteria. Recent cross-sectional studies suggest that reduced ability to generate ammonia from urea in dental plaque can be an important caries risk factor. In spite of this proposed important clinical role, there is currently no information available regarding important clinical aspects of oral ureolysis in children. OBJECTIVE The objective of this study was to evaluate the distribution and pattern of urease activity in the dental plaque and in the saliva of children during a three-year period, and to examine the relationship of urease with some important caries risk factors. METHODS A longitudinal study was conducted with repeated measures over a three-year period on a panel of 80 children, ages three to six years at recruitment. The dynamics of change in urease activity were described and associated with clinical, biological, and behavioral caries risk factors. RESULTS Urease activity in plaque showed a trend to remain stable during the study period and was negatively associated with sugar consumption (P<0.05). Urease activity in unstimulated saliva increased with age, and it was positively associated with the levels of mutans streptococci in saliva and with the educational level of the parents (P<0.05). CONCLUSIONS The results of this study reveal interesting and complex interactions between oral urease activity and some important caries risk factors. Urease activity in saliva could be an indicator of mutans infection in children. PMID:21616477
Morou-Bermudez, E; Elias-Boneta, A; Billings, R J; Burne, R A; Garcia-Rivas, V; Brignoni-Nazario, V; Suarez-Perez, E
2011-11-01
Bacterial urease activity in dental plaque and in saliva generates ammonia, which can increase the plaque pH and can protect acid-sensitive oral bacteria. Recent cross-sectional studies suggest that reduced ability to generate ammonia from urea in dental plaque can be an important caries risk factor. In spite of this proposed important clinical role, there is currently no information available regarding important clinical aspects of oral ureolysis in children. The objective of this study was to evaluate the distribution and pattern of urease activity in the dental plaque and in the saliva of children during a three-year period, and to examine the relationship of urease with some important caries risk factors. A longitudinal study was conducted with repeated measures over a three-year period on a panel of 80 children, aged 3-6 years at recruitment. The dynamics of change in urease activity were described and associated with clinical, biological, and behavioural caries risk factors. Urease activity in plaque showed a trend to remain stable during the study period and was negatively associated with sugar consumption (P<0.05). Urease activity in unstimulated saliva increased with age, and it was positively associated with the levels of mutans streptococci in saliva and with the educational level of the parents (P<0.05). The results of this study reveal interesting and complex interactions between oral urease activity and some important caries risk factors. Urease activity in saliva could be an indicator of mutans infection in children. Copyright © 2011 Elsevier Ltd. All rights reserved.
Robaski, Aliden-Willian; Pamato, Saulo; Tomás-de Oliveira, Marcelo; Pereira, Jefferson-Ricardo
2017-07-01
The enamel condition and the quality of surface are points that need to be considered for achieving optimal efficiency in the treatment with orthodontic brackets. The aim of this study was to assess the immediate bond strength of metallic brackets cemented to dental. Forty human premolars were double-sectioned, placed in PVC matrices and randomly divided into 10 groups (n=8). They received artificial saliva contamination before or after the application of adhesive systems, except for the control groups. The metallic brackets were cemented using two orthodontic cements (Transbond™ Plus Color Change, 3M Unitek e Transbond™ XT Light, 3M Unitek). The specimens were subjected to mechanical shear bond strength testing and classified according to the fracture pattern. The results were analyzed using a two-way ANOVA and Tukey's test for multiple comparisons ( p <0.05). ANOVA analysis showed statistically significant differences between the groups ( p =0.01). The Tukey's multiple comparison test indicated statistically significant difference between G6 and G7 groups ( p <0.05). A high prevalence of adhesive failure in the groups receiving the hydrophobic adhesive system. The saliva contamination prior to the application of a hydrophobic simplified conventional adhesive system was responsible for decreasing the immediate bond strength values of brackets cemented on the dental enamel. Key words: Bonding, orthodontic brackets, shear bond strength, saliva, adhesive systems.
Disintegration of sublingual tablets: proposal for a validated test method and acceptance criterion.
Weda, M; van Riet-Nales, D A; van Aalst, P; de Kaste, D; Lekkerkerker, J F F
2006-12-01
In the Netherlands the market share of isosorbide dinitrate 5 mg sublingual tablets is dominated by 2 products (A and B). In the last few years complaints have been received from health care professionals on product B. During patient use the disintegration of the tablet was reported to be slow and/or incomplete, and ineffectiveness was experienced. In the European Pharmacopoeia (Ph. Eur.) no requirement is present for the disintegration time of sublingual tablets. The purpose of this study was to compare the in vitro disintegration time of products A and B, and to establish a suitable test method and acceptance criterion. A and B were tested with the Ph. Eur. method described in the monograph on disintegration of tablets and capsules as well as with 3 modified tests using the same Ph. Eur. apparatus, but without movement of the basket-rack assembly. In modified test 1 and modified test 2 water was used as medium (900 ml and 50 ml respectively), whereas in modified test 3 artificial saliva was used (50 ml). In addition, disintegration was tested in Nessler tubes with 0.5 and 2 ml of water. Finally, the Ph. Eur. method was also applied to other sublingual tablets with other drug substances on the Dutch market. With modified test 3 no disintegration could be achieved within 20 min. With the Ph. Eur. method and modified tests 1 and 2 product A and B differed significantly (p < 0. 001), with product B having longer disintegration times. These 3 methods were capable of discriminating between products and between batches. The time measured with the Ph. Eur. method was significantly lower compared to modified tests 1 and 2 (p < 0.001) and correlated well with the Nessler tube results. It is concluded that the in vivo complaints on product B could be related to the in vitro data. Furthermore, it is proposed that for immediate release of sublingual tablets the disintegration time should be tested. The Ph. Eur. method is considered suitable for this test. In view of the products currently on the market and taking into consideration requirements in the United States Pharmacopeia and Japanese Pharmacopoeia, an acceptance criterion of not more than 2 min is proposed.
In vitro dentin tubule occlusion and remineralization competence of various toothpastes.
Farooq, Imran; Moheet, Imran Alam; AlShwaimi, Emad
2015-09-01
The purpose of this study was to evaluate dentin tubule occlusion and remineralization competence of various toothpastes containing fluoride, bioactive glass (BG), and hydroxyapatite (HAP) as active ingredients. Sixty dentin discs that were etched with ethylene-diamine-tetraacetic acid (EDTA) were randomly divided into nine groups. The first five groups containing eight dentin discs corresponded to subsequent brushing experiments: control, distilled water, fluoride toothpaste, BG toothpaste, and HAP toothpaste. Scanning electron microscopy (SEM) was used to demonstrate tubule occlusion after 7 days of simulated brushing (twice a day for 2min), which was followed by a citric acid challenge. The discs were stored in freshly prepared artificial saliva (AS) after every brushing cycle. The remaining four groups that contained five discs each received the following treatment: discs kept in distilled water (control), discs kept in a mixture of AS (pH 7.2) and 2g fluoride toothpaste, discs kept in a mixture of AS and 2g BG toothpaste, and discs kept in a mixture of AS and 2g HAP toothpaste. These discs were left in the mixture for one week at 37°C and were then examined under SEM. The pH of the leftover mixture was analyzed using a pH meter. The Wilcoxon signed-rank test was used to identify any statistically significant differences (p<0.05). All toothpastes demonstrated tubule occlusion after simulated brushing experiments. However, after the citric acid challenge, particles of fluoride toothpaste were completely washed away from the tubules whereas HAP and BG toothpastes demonstrated tremendous resistance to the acid challenge. After immersion of the discs in the mixture of AS and toothpaste, HAP and BG toothpastes again showed superior tubule occlusion in comparison to the other groups, but the highest pH increase was observed for fluoride toothpaste after mixing the toothpastes in AS. The results of this study demonstrate that the highest tubule occlusion competence (both pre-and post-citric acid challenge) was achieved by HAP toothpaste, followed by BG toothpaste. After mixing the toothpastes in AS, the highest pH increase was observed for fluoride toothpaste, showing its superior remineralization and buffering capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.
On the ecosystemic network of saliva in healthy young adults
Zaura, Egija; Brandt, Bernd W; Prodan, Andrei; Teixeira de Mattos, Maarten Joost; Imangaliyev, Sultan; Kool, Jolanda; Buijs, Mark J; Jagers, Ferry LPW; Hennequin-Hoenderdos, Nienke L; Slot, Dagmar E; Nicu, Elena A; Lagerweij, Maxim D; Janus, Marleen M; Fernandez-Gutierrez, Marcela M; Levin, Evgeni; Krom, Bastiaan P; Brand, Henk S; Veerman, Enno CI; Kleerebezem, Michiel; Loos, Bruno G; van der Weijden, G A; Crielaard, Wim; Keijser, Bart JF
2017-01-01
A dysbiotic state is believed to be a key factor in the onset of oral disease. Although oral diseases have been studied for decades, our understanding of oral health, the boundaries of a healthy oral ecosystem and ecological shift toward dysbiosis is still limited. Here, we present the ecobiological heterogeneity of the salivary ecosystem and relations between the salivary microbiome, salivary metabolome and host-related biochemical salivary parameters in 268 healthy adults after overnight fasting. Gender-specific differences in the microbiome and metabolome were observed and were associated with salivary pH and dietary protein intake. Our analysis grouped the individuals into five microbiome and four metabolome-based clusters that significantly related to biochemical parameters of saliva. Low salivary pH and high lysozyme activity were associated with high proportions of streptococcal phylotypes and increased membrane-lipid degradation products. Samples with high salivary pH displayed increased chitinase activity, higher abundance of Veillonella and Prevotella species and higher levels of amino acid fermentation products, suggesting proteolytic adaptation. An over-specialization toward either a proteolytic or a saccharolytic ecotype may indicate a shift toward a dysbiotic state. Their prognostic value and the degree to which these ecotypes are related to increased disease risk remains to be determined. PMID:28072421
NASA Astrophysics Data System (ADS)
D'Almeida, Mélanie; Amalric, Julien; Brunon, Céline; Grosgogeat, Brigitte; Toury, Bérangère
2015-02-01
Peri-implant bacterial infections are the main cause of complications in dentistry. Our group has previously proposed the attachment of chitosan on titanium implants via a covalent bond to improve its antibacterial properties while maintaining its biocompatibility. A better knowledge of the coating preparation process allows a better understanding of the bioactive coating in biological conditions. In this work, several relevant characterization techniques were used to assess an implant device during its production phase and its resistance in natural media at different pH. The titanium surface was functionalized with 3-aminopropyltriethoxysilane (APTES) followed by grafting of an organic coupling agent; succinic anhydride, able to form two covalent links, with the substrate through a Ti-O-Si bond and the biopolymer through a peptide bond. Each step of the coating synthesis as well as the presence confirmation of the biopolymer on titanium after saliva immersion was followed by FTIR-ATR, SEM, EDS, 3D profilometry, XPS and ToF-SIMS analyses. Results allowed to highlight the efficiency of each step of the process, and to propose a mechanism occurring during the chitosan coating degradation in saliva media at pH 5 and at pH 3.
Rearing two fruit flies pests on artificial diet with variable pH.
Dias, N P; Nava, D E; Smaniotto, G; Garcia, M S; Valgas, R A
2018-04-23
Fruit flies (Diptera: Tephritidae) are considered the main fruit pests worldwide. In Brazil, two species are predominant: the South American fruit fly, Anastrepha fraterculus and the Mediterranean fruit fly, Ceratitis capitata. In this study, we evaluated the effect of artificial diets with variable pH in their larval development and adult performance. The experiments were carried out in the laboratory at 25 ± 2 °C, 70 ± 10% RH and 12:12h (L:D) photoperiod. Semisolid diets with pH values of 6.0, 5.0, 4.0, 3.0, 2.0, 1.5, and 1.0, adjusted by adding hydrochloric acid were tested. Results indicated that the diet with pH 6.0 did not support larval development of both species of fruit fly. Diets with greater acidic pH values did not allow egg, larvae or pupae development and adult reproduction of A. fraterculus. For C. capitata , the pH of artificial diet exerts greater influence compared to A. fraterculus on the duration and viability of the larval stage, number of pupae, sex ratio and longevity of males.
Li, H. F.; Qiu, K. J.; Yuan, W.; Zhou, F. Y.; Wang, B. L.; Li, L.; Zheng, Y. F.; Liu, Y. H.
2016-01-01
In the present study, the microstructure, mechanical property, castability, corrosion behavior and in vitro cytocompatibility of binary Ti–2X alloys with various alloying elements, including Ag, Bi, Ga, Ge, Hf, In, Mo, Nb, Sn and Zr, were systematically investigated, in order to assess their potential applications in dental field. The experimental results showed that all binary Ti‒2X alloys consisted entirely α–Ti phase. The tensile strength and microhardness of Ti were improved by adding alloying elements. The castability of Ti was significantly improved by separately adding 2 wt.% Bi, Ga, Hf, Mo, Nb, Sn and Zr. The corrosion resistance of Ti in both normal artificial saliva solution (AS) and extreme artificial saliva solution (ASFL, AS with 0.2 wt.% NaF and 0.3 wt.% lactic acid) has been improved by separately adding alloying elements. In addition, the extracts of studied Ti‒2X alloys produced no significant deleterious effect to both fibroblasts L929 cells and osteoblast-like MG63 cells, indicating a good in vitro cytocompatibility, at the same level as pure Ti. The combination of enhanced mechanical properties, castability, corrosion behavior, and in vitro cytocompatibility make the developed Ti‒2X alloys have great potential for future stomatological applications. PMID:27874034
NASA Astrophysics Data System (ADS)
Soares, Luís. Eduardo Silva; Nahorny, Sídnei; Marciano, Fernanda Roberta; Zanin, Hudson; Lobo, Anderson de Oliveira
2015-06-01
New biomaterials such as multi-walled carbon nanotubes oxide/graphene oxide (MWCNTO/GO), nanohydroxyapatite (nHAp) and combination of them together or not to acidulated phosphate fluoride gel (F) have been tested as protective coating before root dentin erosion. Fourteen bovine teeth were cleaned, polished, divided into two parts (n=28) and assigned to seven groups: (Control) - without previous surface treatment; F treatment; nHAp; MWCNTO/GO; F+nHAp; F+MWCNTO/GO and F+MWCNTO/GO/nHAp composites. Each sample had two sites of pre-treatments: acid etched area and an area without treatment. After the biomaterials application, the samples were submitted to six cycles (demineralization: orange juice, 10 min; remineralization: artificial saliva, 1 h). Micro energy-dispersive X-ray fluorescence spectrometry (μ-EDXRF) mapping area analyses were performed after erosive cycling on both sites (n=84). μ-EDXRF mappings showed that artificial saliva and MWCNTO/GO/nHAp/F composite treatments produced lower dentin demineralization than in the other groups. Exposed dentin tubules allowed better interaction of nanobiomaterials than in smear layer covered dentin. Association of fluoride with other biomaterials had a positive influence on acid etched dentin. MWCNTO/GO/nHAp/F composite treatment resulted in levels of demineralization similar to the control group.
NASA Astrophysics Data System (ADS)
Saragih, D. A.; Herda, E.; Triaminingsih, S.
2017-08-01
The aim of this study was to analyze the influence of topical application of 6.5% and 12.5% grapeseed extract gels for duration of application 16 and 32 minutes on the enamel surface hardness following tooth demineralization by an energy drink. The samples were 21 bovine teeth that underwent demineralization by immersion in the energy drink for 5 minutes in an incubator at 37°C. The demineralized specimens were randomly divided into a control group and 2 treatment groups. The control group was immersed in artificial saliva for 6 hours at 37°C, whereas the treatment groups were treated with topical 6.5% and 12.5% grapeseed extract gels for durations of 16 and 32 minutes and then immersed in artificial saliva for 6 hours at 37°C. The hardness was measured with a Knoop hardness tester. Statistical analysis by repeated ANOVA and one-way ANOVA revealed a significant increase in the enamel hardness value (p<0.05) after the application of the topical grapeseed extract gels at both concentrations. Application of 12.5% topical grapeseed extract gel for 32 minutes resulted in a restored hardness that insignificant diffrence from the initial hardness value obtained before demineralization (p>0.05).
Ota, Y; Morito, A; Fujisawa, K; Nishida, M; Hata, H; Ueno, T; Yurikusa, T; Murata, T
2012-11-01
A moisturising micro-gel spray for prevention of dryness was compared with commercial products and artificial saliva in vitro and in a clinical setting in patients with cancer. Survival of cultured human gingival epithelial cells was evaluated after treatment with each product for 15 min. A dry test was performed for products giving a 50% survival rate, in which cell survival was measured after drying of cells treated with each product. The survival rates of cells treated with the micro-gel spray and artificial saliva were significantly higher than those of control cells. The micro-gel spray was then evaluated for 1 week in patients with symptoms of dry mouth caused by cancer treatment. There was significant improvement of these symptoms at night and on awakening and of subjective symptoms of decreased salivary volume (P < 0.05). Mean visual analogue scale scores also significantly decreased (P < 0.01). These data suggest that evaluation of moisturising products for dryness prevention can be performed in cultured cells, since products that performed well in vitro also showed good efficacy for symptoms of dry mouth. The micro-gel spray was particularly effective for relieving symptoms of dry mouth in patients with cancer. © 2012 Blackwell Publishing Ltd.
de Oliveira, Ana Luísa Botta Martins; Botta, Ana Carolina; Campos, Juliana Álvares Duarte Bonini; Garcia, Patrícia Petromilli Nordi Sasso
2014-08-01
This study evaluated the influence of fluoride mouth rinses and repolishing on the superficial morphology and color stability of nanofilled resin. About 150 specimens were prepared and polished using aluminum oxide discs for 15 s with a pressure of 2 kg. The experimental groups were divided according to the immersion medium (artificial saliva, 0.5% sodium fluoride, Fluordent Reach, Oral B, Fluorgard) and repolishing procedure (without and with). The specimens were continuously immersed for 1 week. Thereafter, half of each sample was repolished. A color reading was performed after 24 h of immersion in the artificial saliva baseline, after continuous immersion, and after repolishing. The superficial morphology was examined using scanning electron microscopy (SEM) in a qualitative way. Color change (∆E) data were submitted to a mixed analysis of variance using a Shapiro-Wilk test (p>0.05 for the different immersion media) and Sidak's test (p<0.05 for the differences between groups). In the interaction between the repolishing and the immersion media, Fluorgard showed a statistical difference between the ∆E values with and without repolishing (p<0.0001). On the SEM observations, both Fluordent Reach and Fluorgard caused degradation of the superficial resinous matrix of the composite after continuous immersion. This matrix was removed after repolishing.
Mucosal pH, dental findings, and salivary composition in pediatric liver transplant recipients.
Davidovich, Esti; Asher, Ran; Shapira, Joseph; Brand, Henk S; Veerman, Enno C I; Shapiro, Rivka
2013-07-15
Oral health and dental maintenance have become part of the standard of care for pediatric liver transplant recipients. These individuals tend to suffer particularly from dental problems, such as gingival enlargement, gingivitis, poor oral hygiene, dental hypoplasia, and caries. Saliva composition influences oral hygiene and disease states. We investigated saliva composition and its association with the oral health of young recipients of liver transplants. In 70 patients, 36 liver transplant recipients (ages 2-23 years) and 34 healthy controls (ages 4-21 years), we measured the following variables: (a) oral hygiene, (b) gingival inflammation, (c) caries status, (d) dental calculus formation, (e) oral mucosal pH, and (f) salivary protein composition. Lower mean decayed, missing, and filled teeth index (P=0.0038), higher mean gingival index (P=0.0001), and higher mean calculus score (P=0.003) were found in the transplanted study group compared with the control. The mean mucosal pH for seven intraoral sites was higher in the transplant group (P=0.0006). The median salivary albumin concentration was significantly lower in the transplant group (P=0.01), as was the median salivary albumin/total protein ratio (P=0.0002). In post-liver transplant pediatric recipients, low incidence of caries, together with high incidence of dental calculus, could be attributed to elevated oral mucosal pH. Salivary albumin and immunoglobulin A levels were relatively low in these patients. Clinicians should pay particular attention to the oral health and dental care of liver transplanted children.
The effect of orthodontic bonding materials on dental plaque accumulation and composition in vitro.
Badawi, H; Evans, R D; Wilson, M; Ready, D; Noar, J H; Pratten, J
2003-08-01
The aim of this study was to investigate the accumulation and composition of microcosm dental plaque on different orthodontic bonding materials using an in vitro model. Microcosm plaques were grown on discs of a range of bonding materials in a constant depth film fermentor. The biofilms were derived from human saliva and supplied with artificial saliva as a source of nutrients. The number of viable bacteria in the biofilms was determined and the streptococci present were identified to species level. The results showed that there was no significant difference in bacterial accumulation between different bonding materials, however, biofilms grown on materials which were fluoride releasing, did not contain Streptococcus mutans. This in vitro study has shown that the use of fluoride-releasing bonding materials may support the growth of supragingival plaque, which does not contain S. mutans.
Morzel, Martine; Truntzer, Caroline; Neyraud, Eric; Brignot, Hélène; Ducoroy, Patrick; Lucchi, Géraldine; Canlet, Cécile; Gaillard, Ségolène; Nicod, Florian; Nicklaus, Sophie; Peretti, Noël; Feron, Gilles
2017-05-01
Identifying objective markers of diet would be beneficial to research fields such as nutritional epidemiology. As a preliminary study on the validity of using saliva for this purpose, and in order to explore the relationship between saliva and diet, we focused on clearly contrasted groups of children: children with eating difficulties (ED) receiving at least 50% of their energy intake through artificial nutrition vs healthy controls (C). Saliva of ED and C children was analyzed by various methods (targeted biochemical analyses, 2-D electrophoresis coupled to MS, 1 H NMR) and their diet was characterized using food frequency questionnaires, considering 148 food items grouped into 13 categories. Complete datasets were obtained for 16 ED and 16 C subjects (median age 4.7y and 5.0y, respectively) and the statistical link between salivary and dietary characteristics was studied by Multiple Factor Analysis (MFA). Overall, ED children showed as expected lower consumption frequency scores and higher food selectivity. The two groups of children differed in "diet/saliva" associations. Some distinctive salivary variables were common to both groups of children. For example, carbonic anhydrase 6 and the consumption frequency of biscuits & sweets and drinks were positively associated with the MFA axis 1 in C children, but oppositely associated in ED children. Specifically for ED children, abundant salivary proteins (cystatins, amylase, amylase fragments) and some metabolites (amino acids, galactose, lactate) correlated with axis 1, together with the consumption frequency of sauces & seasonings, bread & cereal products, ready-to-eat meals, fish, biscuits & sweets, drinks and potatoes. Specifically for C children, several proteins (serum albumin, haptoglobin, Igκ, apolipoprotein A-1, α-1 antitrypsin) correlated with axis 1, together with the consumption frequency of biscuits & sweets, milk & dairy products, drinks, fruit, meat and vegetables. This study demonstrates that the qualitative aspect of diet is linked to saliva composition, and that the associations between dietary consumption and salivary composition differ between groups of subjects with contrasted diets. Copyright © 2017 Elsevier Inc. All rights reserved.
Association between nocturnal bruxism and gastroesophageal reflux.
Miyawaki, Shouichi; Tanimoto, Yuko; Araki, Yoshiko; Katayama, Akira; Fujii, Akihito; Takano-Yamamoto, Teruko
2003-11-01
To examine the relationship between nocturnal bruxism and gastroesophageal reflux. Controlled descriptive study and double-blind, placebo-controlled, clinical study. Portable pH monitoring, electromyography, and audio-video recordings were conducted during the night in the subjects' home. Ten patients with bruxism and 10 normal subjects were matched for height, weight, age, and sex. They did not have symptoms of gastroesophageal reflux disease. Medication with a proton pump inhibitor (ie, a gastric-acid-inhibiting drug). The bruxism group showed a significantly higher frequency of nocturnal rhythmic masticatory muscle activity (RMMA) episodes (mean +/- SD: 6.7 +/- 2.2 times per hour) and a higher frequency and percentage of time of gastroesophageal reflux episodes with a pH less than 4.0 and 5.0 (0.5 +/- 0.9 and 3.6 +/- 1.6 times per hour and 1.3% +/- 2.5% and 7.4% +/- 12.6%, respectively) than the control group (RMMA episodes: 2.4 +/- 0.9 times per hour; gastroesophageal reflux episodes: 0.0 +/- 0.0 and 0.1 +/- 0.3 times per hour and 0.0% +/- 0.0% and 0.0% +/- 0.0%, respectively). In the bruxism group, 100% of the gastroesophageal reflux episodes with a pH less than 3.0 and 4.0 included both an RMMA episode and an electromyographic burst, the duration of which was approximately 0.5 to 1.0 seconds, probably representing swallowing of saliva. The majority of gastroesophageal reflux episodes with a pH of 4.0 to 5.0 also included both an RMMA episode and an electromyographic burst in the control and bruxism groups (100% +/- 0.0% vs 70.7% +/- 16.5%), again probably due to swallowing of saliva. The remaining minority of gastroesophageal reflux episodes with a pH of 4.0 to 5.0 contained only an electromyographic burst (swallowing of saliva). The frequency of RMMA episodes after the release of the medication from the proton pump inhibitor, which increased the gastric and esophageal pH, was significantly lower than that after administration of the placebo in the control and bruxism groups (1.0 +/- 0.6 vs 1.9 +/- 3.2 times per hour, and 3.7 +/- 1.9 vs. 6.0 +/- 2.2 times per hour, respectively). Nocturnal bruxism may be secondary to nocturnal gastroesophageal reflux, occurring via sleep arousal and often together with swallowing. The physiologic link between bruxism and the increase in salivation needs to be investigated.
Kong, F X; Liu, Y; Hu, W; Shen, P P; Zhou, C L; Wang, L S
2000-02-01
Biochemical responses of Pinus massoniana, with and without the inoculation mycorrhizal fungus Pisolithus tinctorius at the root, to artificial acid rain (pH 2.0) and various Ca/Al ratios were investigated. Some enzymes associated with the nutritive metabolism, such as acid phosphatase, alkaline phosphatase, nitrate reductase, mannitol dehydrogenase and trehalase, in the roots, stems and leaves of plant were obviously inhibited by the artificial acid rain and Al. After treatment with pH 2.0 + Ca/Al (0/1 or 1/10) artificial acid rain, the protein content in the organs was decreased. However, the activities of superoxide dismutase (SOD) and peroxidase (POD) and glutathione (GSH) concentrations were induced. It demonstrated that acid rain and Al could induce oxygen radicals in plant. Compared with the treatments with lower pH or Al, respectively, the combination of lower pH and Al concentration was more toxic to P. massoniana. Al toxicity could be ameliorated by the addition of Ca and the amelioration was the most when the ratio was 1/1 among the various Ca/Al ratio. Infection with mycorrhizal fungus P. tinctorius at the root of P. massoniana increased the ability of the plant to resist the toxicity of artificial acid rain and Al stress.
Du, Xing; Wang, Feng; Hu, Zhiwei; Wu, Jimin; Wang, Zhonggao; Yan, Chao; Zhang, Chao; Tang, Juan
2017-10-17
None of current diagnostic methods has been proven to be a reliable tool for gastro-esophageal reflux disease (GERD). Pepsin in saliva has been proposed as a promising diagnostic biomarker for gastro-esophageal reflux. We aimed to determine the diagnostic value of salivary pepsin detection for GERD. Two hundred and fifty patients with symptoms suggestive of GERD and 35 asymptomatic healthy volunteers provided saliva on morning waking, after lunch and dinner for pepsin determination using the Peptest lateral flow device. All patients underwent 24-h multichannel intraluminal impedance pH (24-h MII-pH) monitoring and upper gastrointestinal endoscopy. Based on 24-h MII-pH and endoscopy study, patients were defined as GERD (abnormal MII-pH results and/or reflux esophagitis) and non-GERD otherwise. Patients with GERD had a higher prevalence of pepsin in saliva and higher pepsin concentration than patients with non-GERD and healthy controls (P < 0.001 for all). The pepsin test had a sensitivity of 73% and a specificity of 88.3% for diagnosing GERD using the optimal cut-off value of 76 ng/mL. Postprandial saliva samples collected when the symptoms occurred had a more powerful ability to identify GERD. Salivary pepsin test had moderate diagnostic value for GERD. It may be a promising tool to replace the use of currently invasive tools with advantages of non-invasive, easy to perform and cost effective. ChiCTR-DDD-16009506 (date of registration: October 20, 2016).
Salem, A Z M; López, S; Ranilla, M J; González, J S
2013-03-01
Eight Merino sheep (49.4 ± 4.23 kg BW) and 8 Alpine goats (53.2 ± 2.51 kg BW) were used to study the effect of ingestion of quebracho tannins on salivation. Four sheep and 4 goats were individually fed a daily allotment of 20 g DM of alfalfa hay/kg BW (Control). Another 4 sheep and 4 goats were also given 20 g DM of alfalfa hay/kg BW supplemented with 50 g of quebracho/kg DM (Tannin) for a period of 64 d. The saliva secretion from the left parotid gland was collected by insertion of a polyvinyl chloride catheter into the parotid duct and the amount of parotid saliva produced recorded over three 48-h periods on d 1 and 2 (P1), d 31 and 32 (P2), and d 61 and 62 (P3) after the tannin feeding was initiated. The total amount of saliva produced was estimated from rumen water kinetics determined on d 4, d 34, and d 64 of the experiment. Experimental design was completely randomized, with repeated measures on each experimental unit, performing separate analysis for sheep and goats. Parotid saliva production was not affected by the sampling period in either animal species receiving the Control diet. Corresponding values for sheep were 2.04, 2.12, and 2.27 L/d (P = 0.89) and for goats 1.65, 1.79, and 1.86 L/d (P = 0.95). Sheep fed the Tannin diet produced 55, 73, and 107% of the amount of saliva recorded in sheep fed the Control diet on P1, P2, or P3, respectively. Corresponding values in goats were 88, 130, and 134% on P1, P2, or P3, respectively. Estimated total saliva production was not affected (P = 0.50 for sheep and P = 0.97 for goats) by the ingestion of quebracho. There was no difference (P > 0.10) in osmotic pressure, P, Mg, Ca, urea, and protein concentrations in parotid saliva. There were, however, differences in Na and K concentrations in response to the ingestion of quebracho tannins, with Na concentrations increasing (P = 0.05) and K concentrations decreasing (P = 0.04) in sheep saliva and pH increasing (P = 0.05) in goat saliva. In conclusion, the inclusion of quebracho at 50 g/kg DM for 64 d does not appear to alter saliva production in sheep and goats.
Effect of four different opalescence tooth-whitening products on enamel microhardness.
Majeed, A; Grobler, S R; Moola, M H; Rossouw, R J; van Kotze, T J W
2008-06-01
The purpose was to evaluate the effect of various Opalescence tooth-whitening products on enamel. Enamel blocks were exposed to Opalescence PF 10% Carbamide Peroxide (n = 10), Opalescence PF 20% Carbamide Peroxide (n = 10), Opalescence Trèswhite Supreme 10% Hydrogen Peroxide (n = 10) and Opalescence Quick PF 45% Carbamide Peroxide (n = 10) according to the manufacturer's instructions. The control group was enamel blocks (n = 10) kept in artificial saliva. The values were obtained before exposure and after the 14-days treatment period. Enamel blocks were kept in saliva between treatments. Indent marks on enamel blocks were examined using the scanning electron microscope for treatment effects. All four different Opalescence products damaged enamel. The most damage was done when treated for a long period (112 hours). SEM images also showed damage to enamel by all 4 products. Opalescence with 10% and with 20% Carbamide Peroxide showed the highest damage, which also differed significantly (p < 0.05) from the saliva control group (p < 0.05; Tukey-Kramer Multiple comparison test). All 4 Opalescence products damaged enamel. Higher damage was done by the 10% carbamide peroxide and 20% carbamide peroxide products because of the much longer exposure period (112 hours in comparison to 7 hours).
Nordström, Anna; Birkhed, Dowen
2013-01-01
The aim was to investigate fluoride (F) retention in plaque, saliva and pH drop in plaque using high-F toothpaste (5000 ppm F) or standard toothpaste (1450 ppm F) twice a day or 3-times a day. A method using the toothpaste as a 'lotion' and massaging the buccal surfaces with the fingertip was also evaluated. The investigation had a randomized, single-blinded, cross-over design and 16 subjects participated in six brushing regimes: (1) 5000 ppm F; twice a day, (2) 5000 ppm; 3-times/day, (3) 5000 ppm; twice a day, plus the 'massage' method once a day, (4) 1450 ppm F; twice a day, (5) 1450 ppm; 3-times/day and (6) 1450 ppm; twice a day, plus the 'massage' method once a day. The outcome measure was F retention in plaque, saliva and the plaque-pH change after a sucrose rinse. The highest F concentration was found using high-F toothpaste (No 1-3) and differed significantly from those with 1450 ppm (No 4-6). Brushing with high-F toothpaste 3-times a day (No 2) resulted in a 3.6-times higher F saliva value compared with standard toothpaste twice a day (No 4) (p < 0.001). Increasing the frequency of application, from twice to 3-times a day, increased the F retention in plaque significantly when the two methods for application 3-times a day were pooled (p < 0.05). Brushing with 5000 and 1450 ppm toothpastes twice a day plus the 'massage' once a day resulted in the same F concentration in saliva and plaque as brushing 3-times a day with the same paste. A third application of toothpaste is increasing the F retention and toothpaste as a 'lotion' and massaging the buccal surfaces with the fingertip may be a simple and inexpensive way of delivering F a third time during the day.
Influence of sport mouthguards on the ecological factors of the children oral cavity
2014-01-01
Background The use of fixed and/or removable dental devices is an attributable factor that may affect the oral cavity homeostasis. The aim of this study was to monitor the oral environmental changes caused by dental devices, as sports mouthguards with the aid of a chair-side test. Methods Sixty children with sports-mouthguards were analyzed at baseline (T0), after 6 months of dental devices use (T1), after a year (T2) and after almost 6 months without using it (T3). At T0, a clinical monitoring was performed and the DMFT index was recorded. At each time of observation, the following parameters were recorded: FMPS, FMBS, unstimulated-flow rate, saliva consistency, resting pH, stimulated saliva, buffer capacity, the CFU/ml of Streptococcus mutans. Results In 60 subjects, mean age 9.9 ± 1.2, mean value of DMFT 1.55 ± 1.29,dmf-t 3.43 ± 1.21, FMPS and FMBS values increased significantly at T2. The values of unstimulated flow rate vary significantly within the observation times. The pH value and the buffering capacity reduced significantly at T2. The tests for the detection of S. mutans were negative in all the subjects in several observation times. All patients regularly used fluoridated toothpaste and comply with normal standards of oral hygiene; but over time the patients lost their initial motivation. Conclusions Sport treatment with dental devices dues to changes in oral ecological factors: increases FMPS, FMBS and reduces the buffering capacity and the salivary pH. The use of removable devices increases the retentive plaque surfaces and inhibits the protective effect of saliva. The so-called “chair-side” tests were able to easily monitor patients and to determine the risk of oral disease during sport treatment. PMID:25091394
Liang, Kunneng; Zhou, Han; Weir, Michael D; Bao, Chongyun; Reynolds, Mark A; Zhou, Xuedong; Li, Jiyao; Xu, Hockin H K
2017-07-01
Patients with dry mouth often have an acidic oral environment lacking saliva that provides calcium (Ca) and phosphate (P) ions. However, there has been no study on dentin remineralization by placing samples in an acidic solution without Ca and P ions. Previous studies used saliva-like solutions with neutral pH and Ca and P ions. Therefore, the objective of this study was to investigate a novel method of combining poly(amido amine) (PAMAM) with a composite of nanoparticles of amorphous calcium phosphate (NACP) on dentin remineralization in an acidic solution without Ca and P ions for the first time. Demineralized dentin specimens were tested into four groups: (1) dentin control, (2) dentin coated with PAMAM, (3) dentin with NACP nanocomposite, (4) dentin with PAMAM plus NACP composite. Specimens were treated with lactic acid at pH 4 without initial Ca and P ions for 21 days. Acid neutralization and Ca and P ion concentrations were measured. Dentin specimens were examined by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and hardness testing vs. remineralization efficacy. NACP composite had mechanical properties similar to commercial control composites (p>0.1). NACP composite neutralized acid and released Ca and P ions. PAMAM alone failed to induce dentin remineralization. NACP alone achieved mild remineralization and slightly increased dentin hardness at 21days (p>0.1). In contrast, the PAMAM+NACP nanocomposite method in acid solution without initial Ca and P ions greatly remineralized the pre-demineralized dentin, restoring its hardness to approach that of healthy dentin (p>0.1). Dentin remineralization via PAMAM+NACP in pH 4 acid without initial Ca and P ions was demonstrated for the first time, when conventional methods such as PAMAM did not work. The novel PAMAM+NACP nanocomposite method is promising to protect tooth structures, especially for patients with reduced saliva to inhibit caries. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Effect of Lactoferrin on Oral Biofilm Formation
2009-10-01
dental implant failures, denture stomatitis and oral yeast infections such as candidiasis. It is one of the most widely studied biofilm systems, yet...and Company, Sparks, MD) and incubated at 37C for 24 h. P. gingivalis was grown in trypticase soy broth– yeast extract supplemented with 0.05% cysteine...protein, was purchased from (Sigma). In the attachment assays, artificial saliva (1 g lemco (refined meat extract of very light colour), 2 g yeast extract
A ``plasmonic cuvette'': dye chemistry coupled to plasmonic interferometry for glucose sensing
NASA Astrophysics Data System (ADS)
Siu, Vince S.; Feng, Jing; Flanigan, Patrick W.; Palmore, G. Tayhas R.; Pacifici, Domenico
2014-06-01
A non-invasive method for the detection of glucose is sought by millions of diabetic patients to improve personal management of blood glucose over a lifetime. In this work, the synergistic advantage of combining plasmonic interferometry with an enzyme-driven dye assay yields an optical sensor capable of detecting glucose in saliva with high sensitivity and selectivity. The sensor, coined a "plasmonic cuvette," is built around a nano-scale groove-slit-groove (GSG) plasmonic interferometer coupled to an Amplex-red/Glucose-oxidase/Glucose (AR/GOx/Glucose) assay. The proposed device is highly sensitive, with a measured intensity change of 1.7×105%/m (i.e., one order of magnitude more sensitive than without assay) and highly specific for glucose sensing in picoliter volumes, across the physiological range of glucose concentrations found in human saliva (20-240 μm). Real-time glucose monitoring in saliva is achieved by performing a detailed study of the underlying enzyme-driven reactions to determine and tune the effective rate constants in order to reduce the overall assay reaction time to ˜2 min. The results reported suggest that by opportunely choosing the appropriate dye chemistry, a plasmonic cuvette can be turned into a general, real-time sensing scheme for detection of any molecular target, with high sensitivity and selectivity, within extremely low volumes of biological fluid (down to femtoliters). Hereby, we present the results on glucose detection in artificial saliva as a notable and clinically relevant case study.
A Compact Optical Instrument with Artificial Neural Network for pH Determination
Capel-Cuevas, Sonia; López-Ruiz, Nuria; Martinez-Olmos, Antonio; Cuéllar, Manuel P.; Pegalajar, Maria del Carmen; Palma, Alberto José; de Orbe-Payá, Ignacio; Capitán-Vallvey, Luis Fermin
2012-01-01
The aim of this work was the determination of pH with a sensor array-based optical portable instrument. This sensor array consists of eleven membranes with selective colour changes at different pH intervals. The method for the pH calculation is based on the implementation of artificial neural networks that use the responses of the membranes to generate a final pH value. A multi-objective algorithm was used to select the minimum number of sensing elements required to achieve an accurate pH determination from the neural network, and also to minimise the network size. This helps to minimise instrument and array development costs and save on microprocessor energy consumption. A set of artificial neural networks that fulfils these requirements is proposed using different combinations of the membranes in the sensor array, and is evaluated in terms of accuracy and reliability. In the end, the network including the response of the eleven membranes in the sensor was selected for validation in the instrument prototype because of its high accuracy. The performance of the instrument was evaluated by measuring the pH of a large set of real samples, showing that high precision can be obtained in the full range. PMID:22778668
NASA Technical Reports Server (NTRS)
Mehta, Satish K.; Crucian, Brian; Pierson, Duane L.; Sams, Clarence; Stowe, Raymond P.
2007-01-01
Numerous studies have indicated that dysregulation of the immune system occurs during or after spaceflight. Using 21 day -6 degrees head-down tilt bed rest as a spaceflight analog, this study describes the effects of artificial gravity (AG) as a daily countermeasure on immunity, stress and reactivation of clinically important latent herpes viruses. The specific aims were to evaluate psychological and physiological stress, to determine the status of the immune system, and to quantify reactivation of latent herpes viruses. Blood, saliva, and urine samples were collected from each participating subject at different times throughout the study. An immune assessment was performed on all treatment and control subjects that consisted of a comprehensive peripheral immunophenotype analysis, intracellular cytokine profiles and a measurement of T cell function. The treatment group displayed no differences throughout the course of the study with regards to peripheral leukocyte distribution, cytokine production or T cell function. Shedding of Epstein barr virus (EBV), Cytomegalovirus (CMV), and Varicella zoster virus (VZV) was quantified by real time PCR in saliva and urine samples, respectively. There was no significant difference in CMV DNA in the treatment group as compared to the control group. EBV and VZV on the other hand showed a mild reactivation during the study. There were no significant differences in cortisol between the control and treatment groups. In addition, no significant differences between antiviral antibody titers (EBV-VCA, -EA, -EBNA, CMV) or tetramer-positive (EBV, CMV) were found between the two groups. EBV DNA copies in blood were typically undetectable but never exceeded 1,500 copies per 106 PBMCs. Overall, these data indicate that the artificial gravity countermeasure and the 21 day head-down tilt bed rest regimen had no observable adverse effect on immune function.
NASA Technical Reports Server (NTRS)
Mehta, Satish; Crusian, Brian; Pierson, Duane; Sams, Clarence; Stowe, Raymond
2007-01-01
Numerous studies have indicated that dysregulation of the immune system occurs during or after spaceflight. Using 21 day -6 deg. head-down tilt bed rest as a spaceflight analog, this study describes the effects of artificial gravity as a daily countermeasure on immunity, stress and reactivation of clinically important latent herpes viruses. The specific aims were to evaluate psychological and physiological stress, to determine the status of the immune system and to quantify reactivation of latent herpes viruses. Blood, saliva, and urine samples were collected from each participating subject at different times throughout the study. An immune assessment was performed on all treatment and control subjects that consisted of a comprehensive peripheral immunophenotype analysis, intracellular cytokine profiles and a measurement of T cell function. The treatment group displayed no differences throughout the course of the study with regards to peripheral leukocyte distribution, cytokine production or T cell function. Shedding of EBV and CMV was quantified by real time PCR in saliva and urine samples, respectively. There was no significant difference in CMV DNA in the treatment group as compared to the control group. EBV and VZV on the other hand showed a mild reactivation during the study. There were no significant differences in plasma cortisol between the control and treatment groups. In addition, no significant differences between antiviral antibody titers (EBV-VCA, -EA, -EBNA, CMV) or tetramer-positive (EBV, CMV) were found between the two groups. EBV DNA copies in blood were typically undetectable but never exceeded 1,500 copies per 10(exp 6) PBMCs. These data indicate that the artificial gravity countermeasure and the 21 day head-down tilt bed rest regimen had no observable adverse effect on immune function.
Unstimulated salivary flow rate, pH and buffer capacity of saliva in healthy volunteers.
Fenoll-Palomares, C; Muñoz Montagud, J V; Sanchiz, V; Herreros, B; Hernández, V; Mínguez, M; Benages, A
2004-11-01
To assess the salivary flow rate, pH, and buffer capacity of healthy volunteers, and their relationships with age, gender, obesity, smoking, and alcohol consumption, and to establish the lower-end value of normal salivary flow (oligosialia). A prospective study was conducted in 159 healthy volunteers (age > 18 years, absence of medical conditions that could decrease salivary flow). Unstimulated whole saliva was collected during ten minutes, and salivary flow rate (ml/min), pH, and bicarbonate concentration (mmol/l) were measured using a Radiometer ABL 520. The 5 percentile of salivary flow rate and bicarbonate concentration was considered the lower limit of normality. Median salivary flow rate was 0.48 ml/min (range: 0.1-2 ml/min). Age younger than 44 years was associated with higher flow rates (OR 2.10). Compared with women, men presented a higher flow rate (OR 3.19) and buffer capacity (OR 2.81). Bicarbonate concentration correlated with salivary flow rate. The lower-end values of normal flow rate and bicarbonate concentration were 0.15 ml/min and 1.800 mmol/l, respectively. The presence of obesity, smoking, and alcohol consumption did not influence salivary parameters. In healthy volunteers, salivary flow rate depends on age and gender, and correlates with buffer capacity. Obesity, smoking, and alcohol use do not influence salivary secretion.
Ionescu, S; Bădiţă, D; Artino, M; Dragomir, M; Huidovici, E; Niţă, V; Chiţoi, E
1998-01-01
The study was performed on 31 diabetic patients of both sexes, divided in 2 groups: group I--17 patients with insulin-dependent diabetes (IDDM) and group II--14 patients with noninsulin-dependent diabetes (NIDDM) and compared with a control group of 16 non-diabetic subjects. Mixed saliva was sampled without stimulation during 2 periods of the day: 07:30-08:00 before breakfast and 17:30-18:00 before dinner. We determined: salivary flow rate, pH with Merck indicator and, after homogenization, the thiocianat with the FeCl3 method and LDH activity (the Norbert method adapted in our laboratory for saliva). Our study showed the same diurnal changes in flow rate and salivary pH in both diabetic and control groups: minimal values in the morning and maximal ones in the afternoon. In non-smoking diabetic patients the salivary thiocianat had maximal values in the morning and minimal ones in the afternoon; similar behaviour, but less obvious was observed in smoking diabetic patients and in the control group regardless of the smoking habit. LDH activity showed unsignificant diurnal variations in the diabetic patients. In the control group we found a significant decrease of LDH activity in the afternoon. The discussion is about the implication of these salivary parameters in the pathology of oral cavity: gingivitis, periodontitis and caries in diabetic patients.
Díaz Rosas, C Y; Cárdenas Vargas, E; Castañeda-Delgado, J E; Aguilera-Galaviz, L A; Aceves Medina, M C
2018-06-01
Diabetes mellitus is a chronic disease that has manifestations other than alterations in endocrine regulation or in metabolic pathways. Several diseases of the oral cavity have been associated with diabetes mellitus type 1 and 2 in young people according to their evolution. Scarce information exists regarding the role of diabetes and its association with the oral health status in paediatric diabetic patients. The aims of the study were to assess the quality of saliva, saliva acidogenicity, dental caries experience, fluorosis and periodontal status in diabetic patients and to evaluate their relationship with metabolic control variables and nutritional plan adherence. The study population consisted of 60 paediatric patients with both types of diabetes mellitus. Saliva testing included stimulated flow, pH (using pH indicator strips), buffer capacity and Snyder's Test. DMFT/dmft and dental caries experience were determined on the basis of ICDAS II codes. The periodontal status was assessed by PI and GI and fluorosis by FI. Nutritional plan adherence was established from the subscale "Dietary Control" of the Diabetes Self-Management Profile questionnaire. Medical Data was retrieved from the clinical registers in the Diabetic Clinic. We describe the main characteristics of the oral cavity related variables of our population that might guide the clinical practice in similar settings; we found a dmft/DMFT of 1.71 ± 1.74 and 0.64 ± 1.03, PI of 1.91 ± 0.75, GI of 0.50 ± 0.56 and a fluorosis prevalence of 61%. We identified several correlated variables, which indicate strong associations between the nutritional habits of the patients and co-occurrence of oral cavity physiopathological alterations. Several correlations were found between acidogenic activity of the saliva (Snyder Test) and the percentage of adherence to the nutritional plan and to the dmft index. Furthermore, a significant correlation between the buffering capacity of the saliva and the glycemic control of the participants was found. Neither an association nor a difference among means was found between treatment regime and the plaque index. The results of the present study concluded that there was a significant relationship between diabetes mellitus and an increased prevalence of oral cavity related diseases in the paediatric population. These are also associated with a poor adherence to the nutritional plan.
Elkafri, I H; Mashlah, A; Shaqifa, A
2014-03-13
This study was evaluated the relationship between blood glucose levels and salivary pH and buffering capacity in type II diabetic patients. The sample comprised 210 participants (age ranged 40-60 years). Based on fasting blood glucose levels the participants were divided into 3 groups: controls with normal blood glucose levels; diabetic patients with levels ≤ 200 mg/dL; and diabetic patients with levels > 200 mg/dL. Salivary pH and buffering capacity were determined in a sample of resting (non-stimulated) saliva taken from each participant. Salivary pH levels in diabetic patients with blood glucose levels > 200 mg/dL were lower than in the controls and diabetic patients with levels ≤ 200 mg/dL. Salivary pH levels were comparable in controls and diabetic patients with blood glucose levels ≤ 200 mg/dL. Salivary buffering capacity in the 3 groups was comparable.
Bradna, Pavel; Vrbova, Radka; Fialova, Vlasta; Housova, Devana; Gojisova, Eva
2016-09-01
This study investigated formation of protective deposits on the enamel surface after application of several anti-erosive toothpastes with different active ingredients. NaF-containing Sensodyne Pronamel, SnCl 2 /F-based Elmex Erosion Protection and calcium phosphate-based BioRepair Plus Sensitivity Control, SensiShield and Enamel Care toothpastes with claimed anti-erosive properties were tested. Artificial saliva and Elmex Erosion Protection mouth rinse served as control groups. The toothpastes were applied 30 times by a toothbrush for 2 min per day, mouth rinse for 30 s on polished enamel of thirty five human molars (n = 5) with series of five rhomboid-shaped indents of various length prepared by a Knoop indentor. After 15 and 30 applications, the shape of the indents and surface morphology was characterised using light and scanning electron microscopy. At the end of treatment, the samples were exposed to 0.2 wt. % citric acid (pH 3.30) to test resistance of the treated enamel to erosion. Pronounced differences were observed between protective properties of the toothpastes. While Sensodyne Pronamel and BioRepair Plus Sensitivity Control did not produce any protective deposits, Enamel Care formed a compact layer of deposits which protected the enamel surface against erosion. With Elmex Erosion Protection and SensiShield fractured indent edges and scratches on the treated enamel suggested that their abrasive properties prevailed over ability of active ingredients to form deposits. These results revealed that toothpastes with strong potential to form acid-resistant deposits on the enamel surface and of low abrasivity should be used for effective prevention of enamel erosion. SCANNING 38:380-388, 2016. © 2015 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Churchley, David; Lippert, Frank; Lynch, Richard; Alton, Jesse; Gonzalez-Cabezas, C.; Eder, J.
2009-02-01
The aim of this study was to determine the ability of Terahertz Pulsed Imaging (TPI) to measure mineral changes in enamel lesions during de/remineralisation studies. A comparison was made between transverse microradiography (TMR) and microhardness measurements. Artificial lesions were formed in bovine enamel using a solution of 0.1 M lactic acid (pH 5.0) containing 0.2% Carbopol C907 and 50% saturated with hydroxyapatite. The 20 day experimental protocol consisted of four, one-minute treatment periods with dentifrices containing 10, 675, 1385 and 2700ppm fluoride, a 4 h/day acid challenge, and for the remaining time specimens were stored in a 50:50 pooled human / artificial saliva mixture. Terahertz images were generated by positioning the specimens at the focus of the beam and raster scanning the optics to collect the reflections from the air / enamel (AEI) and lesion / enamel (LEI) interface. Significant differences were observed in the intensity change from baseline of the AEI and LEI reflections upon treatment with the four dentifrices. A linear correlation was observed between ΔAEI vs ΔVHN (r2 = 0.997), ΔAEI vs ΔKHN (r2 =0.964), ΔII (ratio of LEI to AEI) vs ΔΔZ (r2 =0.875) and ΔLEI vs ΔΔZ (r2 =0.870). Statistically significant correlations (p<0.05 Pearson correlation coefficient) were also found between the TPI and microhardness / microradiography data. This study has demonstrated that TPI is a useful technology to measure in vitro (and possibly in situ) mineral changes in enamel and is sufficiently sensitive to discriminate between the levels of remineralization produced by the different dentifrices.
In Vitro Comparative Study of Two Different Bleaching Agents on Micro-hardness Dental Enamel.
Fatima, Nazish; Ali Abidi, Syed Yawar; Meo, Ashraf Ali
2016-02-01
To evaluate the effect of home-use bleaching agent containing 16% Carbamide Peroxide (CP) and in-office bleaching agent containing 38% Hydrogen Peroxide (HP) on enamel micro-hardness. An in vitroexperimental study. Department of Operative Dentistry and Science of Dental Materials at Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences and Material Engineering Department of NED University of Engineering and Technology, Karachi, from July to December 2014. Atotal of 90 enamel slabs from 45 sound human 3rd molar were randomly divided into 3 groups. Each group contained 30 specimens (n=30). Group 1 was kept in artificial saliva at 37°C in incubator during the whole experiment. However, Groups 2 and 3 were treated with power whitening gel and tooth whitening pen respectively. After bleaching session, specimens were thoroughly rinsed with deionized water again for 10 seconds and then stored in artificial saliva at 37°C in incubator. Artificial saliva was changed after every 2 days. The Vickers hardness tester (Wolpert 402 MVD, Germany) was adjusted to a load of 0.1 kg (100 gm) and dwell time of 5 seconds. Three Vickers were performed on each specimen using a hardness tester according to the ISO 6507-3:1998 specification. Micro-hardness measurements were performed before and after bleaching at day 1, 7 and 14. In the control group, the baseline micro-hardness was 181.1 ±9.3 which was reduced after the storage on day 1, 7 and 14 (p = 0.104). In Group 2, baseline micro-hardness was 180.4 ±10.1 which was reduced to 179.79 ±10.0 units after day 1. Whereas, on day 7 and 14, the values of micro-hardness were 179.8 ±10 and 179.7 ±10.29, respectively (p=0.091). Furthermore, the baseline micro-hardness in Group 3 was 174.0 ±22.9 units which was reduced to 173 ±23 on day 1, 170 ±30 on day 7 and 173 ±23 on day 14 (p = 0.256). The statistically insignificant difference was found among micro-hardness values of different bleaching agents (p = 0.118). Bleaching with 38% Hydrogen Peroxide (HP) and 16% Carbamide Peroxide (CP) resulted in insignificant effect on surface micro-hardness of enamel.
Rosalbino, F; Delsante, S; Borzone, G; Scavino, G
2012-05-01
Titanium alloys exhibit excellent corrosion resistance in most aqueous media due to the formation of a stable oxide film, and some of these alloys (particularly Ti-6Al-7Nb) have been chosen for surgical and odontological implants for their resistance and biocompatibility. Treatment with fluorides (F(-)) is known to be the main method for preventing plaque formation and dental caries. Toothpastes, mouthwashes, and prophylactic gels can contain from 200 to 20,000 ppm F(-) and can affect the corrosion behaviour of titanium alloy devices present in the oral cavity. In this work, the electrochemical corrosion behaviour of Ti-1M alloys (M = Ag, Au, Pd, Pt) was assessed in artificial saliva of pH = 3.0 containing 910 ppm F(-) (0.05 M NaF) through open circuit potential, E(OC), and electrochemical impedance spectroscopy (EIS) measurements. The corrosion behaviour of the Ti-6Al-7Nb commercial alloy was also evaluated for comparison. E (OC) measurements show an active behaviour for all the titanium alloys in fluoridated acidified saliva due to the presence of significant concentrations of HF and HF(2) (-) species that dissolve the spontaneous air-formed oxide film giving rise to surface activation. However, an increase in stability of the passive oxide layer and consequently a decrease in surface activation is observed for the Ti-1M alloys. This behaviour is confirmed by EIS measurements. In fact, the Ti-6Al-7Nb alloy exhibits lower impedance values as compared with Ti-1M alloys, the highest values being measured for the Ti-1Au alloy. The experimental results show that the corrosion resistance of the studied Ti-1M alloys is similar to or better than that of Ti-6Al-7Nb alloy currently used as biomaterial, suggesting their potential for dental applications.
Long-term effect of tobacco on unstimulated salivary pH.
Grover, Neeraj; Sharma, Jyoti; Sengupta, Shamindra; Singh, Sanjeet; Singh, Nishant; Kaur, Harjeet
2016-01-01
The aim of this study was to analyze and compare the effects of tobacco on salivary pH between tobacco chewers, smokers and controls. A total of 60 subjects (males and females) aged 25-40 years, were divided equally into three groups: Tobacco smokers (Group A), chewers (Group B) and controls (Group C). Saliva of each subject was collected under resting condition. Salivary pH was determined using the specific salivary pH meter. The mean (±standard deviation) pH for Group A was 6.75 (±0.11), Group B was 6.5 (±0.29) and Group C was 7.00 (±0.28) after comparison. The significant results showed lower salivary pH in Groups A and B as compared to controls. Salivary pH was lowest in Group B compared to Group A and Group C. This study indicates that a lower (acidic) salivary pH was observed in tobacco users as compared with control. These alterations in pH due to the long-term effect of tobacco use can render oral mucosa vulnerable to various oral and dental diseases.
Levels of salivary stress markers in patients with anxiety about halitosis.
Fukui, Makoto; Hinode, Daisuke; Yokoyama, Masaaki; Yoshioka, Masami; Kataoka, Kosuke; Ito, Hiro-O
2010-11-01
To investigate the relationship between salivary stress markers and mental stress states in patients complaining of oral malodour. The utility of the salivary stress markers in assessment of mental conditions of those patients was also investigated. The study population included 74 patients, aged 20-59 years, who complained of oral malodour and were referred to the Breath Odor Clinic at Tokushima University Hospital. Patients were classified into two groups, genuine halitosis (GH) and psychosomatic halitosis (PH), according to the results of organoleptic rating measurement. All patients were subjected to examination by the Cornell Medical Index (CMI) Health Questionnaire. Resting saliva was collected and levels of salivary IgA, cortisol and chromogranin A were determined by ELISA. Twenty-three volunteers not complaining of halitosis were included as the control group. Kruskal-Wallis test and Mann-Whitney's U-test were used for statistical analysis. A significant increase was observed in the concentrations of salivary cortisol in the PH group as compared with GH and control groups (p<0.05). Concentrations of IgA and chromogranin A in saliva were not significantly different among the three groups. In addition, higher salivary cortisol concentrations were found in CMI scale III and IV (tendency towards neurosis) than in scale I and II (normal) (p<0.05). Since salivary cortisol reflects a status of chronic stress condition, psychosomatic halitosis might be closely related to this state of chronic stress. Determination of cortisol levels in saliva may provide useful information for evaluating the mental status of patients complaining of halitosis. Copyright © 2010 Elsevier Ltd. All rights reserved.
Berry, Robert E; Muthu, Dhanasekaran; Yang, Fei; Walker, F Ann
2015-01-20
The β-barrel nitrophorin (NP) heme proteins are found in the saliva of the blood-sucking insect Rhodnius prolixus, which synthesizes and stores nitric oxide (NO) in the salivary glands. NO is bound to iron of the NPs and is released by dilution and an increase in pH when the insect spits its saliva into the tissues of a victim, to aid in obtaining a blood meal. In the adult insect, there are four nitrophorins, NP1-NP4, which have sequence similarities in two pairs, NP1 and NP4 (90% identical) and NP2 and NP3 (80% identical). The available crystal structures of NP4 have been used to propose that pH-dependent changes in the conformation of two loops between adjacent β-strands at the front opening of the protein, the A-B and G-H loops, determine the rate of NO release. At pH 7.3, NP4 releases NO 17 times faster than NP2 does. In this work, the aqua complexes of NP4 and NP2 have been investigated by nuclear magnetic resonance (NMR) relaxation measurements to probe the pico- to nanosecond and micro- to millisecond time scale motions at two pH values, 6.5 and 7.3. It is found that NP4-OH2 is fairly rigid and only residues in the loop regions show dynamics at pH 6.5; at pH 7.3, much more dynamics of the loops and most of the β-strands are observed while the α-helices remain fairly rigid. In comparison, NP2-OH2 shows much less dynamics, albeit somewhat more than that of the previously reported NP2-NO complex [Muthu, D., Berry, R. E., Zhang, H., and Walker, F. A. (2013) Biochemistry 52, 7910-7925]. The reasons for this major difference between NP4 and NP2 are discussed.
2015-01-01
The β-barrel nitrophorin (NP) heme proteins are found in the saliva of the blood-sucking insect Rhodnius prolixus, which synthesizes and stores nitric oxide (NO) in the salivary glands. NO is bound to iron of the NPs and is released by dilution and an increase in pH when the insect spits its saliva into the tissues of a victim, to aid in obtaining a blood meal. In the adult insect, there are four nitrophorins, NP1–NP4, which have sequence similarities in two pairs, NP1 and NP4 (90% identical) and NP2 and NP3 (80% identical). The available crystal structures of NP4 have been used to propose that pH-dependent changes in the conformation of two loops between adjacent β-strands at the front opening of the protein, the A–B and G–H loops, determine the rate of NO release. At pH 7.3, NP4 releases NO 17 times faster than NP2 does. In this work, the aqua complexes of NP4 and NP2 have been investigated by nuclear magnetic resonance (NMR) relaxation measurements to probe the pico- to nanosecond and micro- to millisecond time scale motions at two pH values, 6.5 and 7.3. It is found that NP4-OH2 is fairly rigid and only residues in the loop regions show dynamics at pH 6.5; at pH 7.3, much more dynamics of the loops and most of the β-strands are observed while the α-helices remain fairly rigid. In comparison, NP2-OH2 shows much less dynamics, albeit somewhat more than that of the previously reported NP2-NO complex [Muthu, D., Berry, R. E., Zhang, H., and Walker, F. A. (2013) Biochemistry 52, 7910–7925]. The reasons for this major difference between NP4 and NP2 are discussed. PMID:25486224
Sima, Michal; Ferencova, Blanka; Warburg, Alon; Rohousova, Iva; Volf, Petr
2016-01-01
Background Certain salivary proteins of phlebotomine sand flies injected into the host skin during blood-feeding are highly antigenic and elicit strong antibody-mediated immune responses in repeatedly-exposed hosts. These antibodies can be measured by enzyme-linked immuno sorbent assays (ELISAs) using salivary gland homogenates (SGHs) as the source of antigens and serve as a markers for exposure to biting sand flies. Large-scale screening for anti-sand fly saliva antibodies requires replacement of SGH with recombinant salivary proteins. In East Africa, Phlebotomus orientalis is the main vector of Leishmania donovani, a trypanosomatid parasite causing visceral leishmaniasis. We tested recombinant salivary proteins derived from Ph. orientalis saliva to study exposure of domestic animals to this sand fly species. Methodology/Principal Findings Antigenic salivary proteins from Ph. orientalis were identified by immunoblot and mass spectrometry. Recombinant apyrase rPorSP15, yellow-related protein rPorSP24, ParSP25-like protein rPorSP65, D7-related protein rPorSP67, and antigen 5-related protein rPorSP76 were tested using ELISA with sera of domestic animals from L. donovani foci in Ethiopia where Ph. orientalis is present. Our results highlighted recombinant yellow-related protein rPorSP24 as the most promising antigen, displaying a high positive correlation coefficient as well as good sensitivity and specificity when compared to SGH. This recombinant protein was the most suitable one for testing sera of dogs, sheep, and goats. In addition, a different antigen, rPorSP65 was found efficacious for testing canine sera. Conclusions/Significance Recombinant salivary proteins of Ph. orientalis, specifically rPorSP24, were shown to successfully substitute SGH in serological experiments to measure exposure of domestic animals to Ph. orientalis, the vector of L. donovani. The results suggest that rPorSP24 might be a suitable antigen for detecting anti-Ph. orientalis antibody-mediated reactions also in other host species. PMID:26986566
Sima, Michal; Ferencova, Blanka; Warburg, Alon; Rohousova, Iva; Volf, Petr
2016-03-01
Certain salivary proteins of phlebotomine sand flies injected into the host skin during blood-feeding are highly antigenic and elicit strong antibody-mediated immune responses in repeatedly-exposed hosts. These antibodies can be measured by enzyme-linked immuno sorbent assays (ELISAs) using salivary gland homogenates (SGHs) as the source of antigens and serve as a markers for exposure to biting sand flies. Large-scale screening for anti-sand fly saliva antibodies requires replacement of SGH with recombinant salivary proteins. In East Africa, Phlebotomus orientalis is the main vector of Leishmania donovani, a trypanosomatid parasite causing visceral leishmaniasis. We tested recombinant salivary proteins derived from Ph. orientalis saliva to study exposure of domestic animals to this sand fly species. Antigenic salivary proteins from Ph. orientalis were identified by immunoblot and mass spectrometry. Recombinant apyrase rPorSP15, yellow-related protein rPorSP24, ParSP25-like protein rPorSP65, D7-related protein rPorSP67, and antigen 5-related protein rPorSP76 were tested using ELISA with sera of domestic animals from L. donovani foci in Ethiopia where Ph. orientalis is present. Our results highlighted recombinant yellow-related protein rPorSP24 as the most promising antigen, displaying a high positive correlation coefficient as well as good sensitivity and specificity when compared to SGH. This recombinant protein was the most suitable one for testing sera of dogs, sheep, and goats. In addition, a different antigen, rPorSP65 was found efficacious for testing canine sera. Recombinant salivary proteins of Ph. orientalis, specifically rPorSP24, were shown to successfully substitute SGH in serological experiments to measure exposure of domestic animals to Ph. orientalis, the vector of L. donovani. The results suggest that rPorSP24 might be a suitable antigen for detecting anti-Ph. orientalis antibody-mediated reactions also in other host species.
Corrosion of dental alloys in artificial saliva with Streptococcus mutans.
Lu, Chunhui; Zheng, Yuanli; Zhong, Qun
2017-01-01
A comparative study of the corrosion resistance of CoCr and NiCr alloys in artificial saliva (AS) containing tryptic soy broth (Solution 1) and Streptococcus mutans (S. mutans) species (Solution 2) was performed by electrochemical methods, including open circuit potential measurements, impedance spectroscopy, and potentiodynamic polarization. The adherence of S. mutans to the NiCr and CoCr alloy surfaces immersed in Solution 2 for 24 h was verified by scanning electron microscopy, while the results of electrochemical impedance spectroscopy confirmed the importance of biofilm formation for the corrosion process. The R(QR) equivalent circuit was successfully used to fit the data obtained for the AS mixture without S. mutans, while the R(Q(R(QR))) circuit was found to be more suitable for describing the biofilm properties after treatment with the AS containing S. mutans species. In addition, a negative shift of the open circuit potential with immersion time was observed for all samples regardless of the solution type. Both alloys exhibited higher charge transfer resistance after treatment with Solution 2, and lower corrosion current densities were detected for all samples in the presence of S. mutans. The obtained results suggest that the biofilm formation observed after 24 h of exposure to S. mutans bacteria might enhance the corrosion resistance of the studied samples by creating physical barriers that prevented oxygen interactions with the metal surfaces.
[Effect of chloride ion on corrosion of two commonly used dental alloys].
Chen, Lei; Zhang, Weidan; Zhang, Yuanyuan
2014-11-01
To investigate the eff ect of chloride concentration on the corrosion of Co-Cr alloy and pure Ti in a simulated oral environment. The electrochemical corrosion tests of pure Ti and Co-Cr alloy were carried out in neutral artificial saliva solutions with different NaCl concentrations (0.9%, 2.0%, and 3.0%). Th e morphologies of corroded surface for pure Ti and Co-Cr alloy were observed by scanning electron microscope (SEM). Th e changes in the self-corrosion potentials (Ecorr) for pure Ti and Co-Cr alloy in three kinds of artificial saliva solutions was not obvious. However, the self-corrosion current densities (Icorr) of pure Ti were much lower than those of Co-Cr. The Icorr of Co-Cr alloy increased in a concentration-dependent manner of NaCl, whereas the breakdown potential (Eb) of Co-Cr alloy decreased in a concentration-dependent manner. Th e potential ranged for the breakdown of oxide film (Ev) was shortened in a concentration-dependent manner of NaCl. There was no obvious difference in the Icorr of pure Ti with different concentrations of NaCl. The breakdown potential was not seen according to the polarization curves. In a certain range, the increase of the concentration of Cl- leads to accelerate the corrosion behavior of Co-Cr alloy, but it does not affect pure Ti.
Effect of a novel bioactive glass-ceramic on dentinal tubule occlusion: an in vitro study.
Zhong, Y; Liu, J; Li, X; Yin, W; He, T; Hu, D; Liao, Y; Yao, X; Wang, Y
2015-03-01
This in vitro study aimed to assess the ability and efficacy of HX-BGC, a novel bioactive glass-ceramic (SiO2-P2 O5-CaO-Na2 O-SrO), to reduce dentine tubule permeability. Dentine discs from human third molars were etched and randomly allocated into five groups: Group 1--distilled water; Group 2--Sensodyne Repair toothpaste (containing NovaMin®); Group 3--HX-BGC toothpaste (containing 7.5% HX-BGC); Group 4--control toothpaste (without HX-BGC); and Group 5--HX-BGC powder. Specimens were treated daily by brushing with an electric toothbrush for 20 seconds. Between daily treatments (7 days total), specimens were immersed in artificial saliva for 24 hours. Dentine permeability was measured at baseline, after the first treatment, after the first 24-hour immersion in artificial saliva and at the end of day 7. Dentine morphology and surface deposits were observed by scanning electron microscopy after one day and 7 days of treatment, respectively. Sensodyne Repair and bioactive glass-ceramic toothpaste significantly and immediately lowered dentine permeability. The HX-BGC powder group showed the highest reduction in dentine permeability after 7 days of treatment. The novel bioactive glass-ceramic material HX-BGC is effective in reducing dentine permeability by occluding open dentine tubules, indicating that HX-BGC may be a potential treatment for dentine hypersensitivity. © 2015 Australian Dental Association.
Comparison of metal ion release from different bracket archwire combinations: an in vitro study.
Karnam, Srinivas Kumar; Reddy, A Naveen; Manjith, C M
2012-05-01
The metal ion released from the orthodontic appliance may cause allergic reactions particularly nickel and chromium ions. Hence, this study was undertaken to determine the amount of nickel, chromium, copper, cobalt and iron ions released from simulated orthodontic appliance made of new archwires and brackets. Sixty sets of new archwire, band material, brackets and ligature wires were prepared simulating fixed orthodontic appliance. These sets were divided into four groups of fifteen samples each. Group 1: Stainless steel rectangular archwires. Group 2: Rectangular NiTi archwires. Group 3: Rectangular copper NiTi archwires. Group 4: Rectangular elgiloy archwires. These appliances were immersed in 50 ml of artificial saliva solution and stored in polypropylene bottles in the incubator to simulate oral conditions. After 90 days the solution were tested for nickel, chromium, copper, cobalt and iron ions using atomic absorption spectrophotometer. Results showed that high levels of nickel ions were released from all four groups, compared to all other ions, followed by release of iron ion levels. There is no significant difference in the levels of all metal ions released in the different groups. The study confirms that the use of newer brackets and newer archwires confirms the negligible release of metal ions from the orthodontic appliance. The measurable amount of metals, released from orthodontic appliances in artificial saliva, was significantly below the average dietary intake and did not reach toxic concentrations.
Penumatsa, Narendra Varma; Kaminedi, Raja Rajeswari; Baroudi, Kusai; Barakath, Ola
2015-01-01
Objective: The aim of this study was to evaluate the potential of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) in remineralizing the bleached enamel surface using micro-hardness. Materials and Methods: Thirty human enamel slabs were randomly divided into three groups (n = 10). Groups A and B were exposed to 20% carbamide peroxide and 35% carbamide peroxide gel, respectively. After the exposure to the bleaching agent, the slabs were kept in artificial saliva for 1-week. Group C (control group) were kept in artificial saliva for 1-week. Vickers micro-hardness test was performed by Leica VMHT-Mot micro-hardness tester. CPP-ACP (Gc Tooth Mousse, Melbourne, Australia) was then applied to specimens of Groups A and B for 3 min for 2 weeks. Micro-hardness values of postbleach Group A (Ar) and Group B (Br) were recorded and statistically analyzed by paired t-test and one-way analysis of variance at the significance level of α =0.05. Results: There was a significant decrease in micro-hardness of enamel in carbamide peroxide bleached groups. However, there was a significant increase in micro-hardness after the remineralization by CPP-ACP and the extent of remineralization is more for the Group B. Conclusions: That bleaching agents reduced enamel micro-hardness and the use of CPP-ACP after bleaching can significantly enhance the micro-hardness of bleached enamel. PMID:26538923
Shahabi, Mostafa; Salari, Soheil; Poosti, Maryam; Abtahi, Mostafa
2017-01-01
During sliding mechanics, the frictional force (FF) is an important counterforce to orthodontic tooth movement. The purpose of this in vitro study was to investigate the static and kinetic FFs of S silica-insert ceramic (SIC) brackets with Teflon-coated (TC) and conventional S stainless steel (SS) archwires. The target group of this study included 80 maxillary canine 0.022 inch slot SIC brackets. Forty SS brackets were used as the control. TC and conventional uncoated SS archwires of different dimensions (0.016, 0.018, 0.016 × 0.022, and 0.018 × 0.025 inch) were examined. All tests were carried out under artificial saliva injected condition. Scanning Electron Micrographs were prepared for two samples of coated and uncoated archwires. Analysis of variance and Tukey post hoc tests were used for statistical purposes (level of significance P < 0.05). SIC brackets showed significantly lower levels of FFs than SS brackets. TC archwires had greater frictional values than conventional uncoated ones. They also exhibited an unusual behavior of increasing kinetic FFs with time. Indentation and delamination of coating were obvious under scanning electron microscopy observations. From the standpoint of friction, SIC brackets may serve well, even better than SS brackets, in sliding mechanics. The coating layer of the archwires may delaminate and lost, causing an impediment to tooth movement.
Shahabi, Mostafa; Salari, Soheil; Poosti, Maryam; Abtahi, Mostafa
2017-01-01
Background: During sliding mechanics, the frictional force (FF) is an important counterforce to orthodontic tooth movement. The purpose of this in vitro study was to investigate the static and kinetic FFs of S silica-insert ceramic (SIC) brackets with Teflon-coated (TC) and conventional S stainless steel (SS) archwires. Materials and Methods: The target group of this study included 80 maxillary canine 0.022 inch slot SIC brackets. Forty SS brackets were used as the control. TC and conventional uncoated SS archwires of different dimensions (0.016, 0.018, 0.016 × 0.022, and 0.018 × 0.025 inch) were examined. All tests were carried out under artificial saliva injected condition. Scanning Electron Micrographs were prepared for two samples of coated and uncoated archwires. Analysis of variance and Tukey post hoc tests were used for statistical purposes (level of significance P < 0.05). Results: SIC brackets showed significantly lower levels of FFs than SS brackets. TC archwires had greater frictional values than conventional uncoated ones. They also exhibited an unusual behavior of increasing kinetic FFs with time. Indentation and delamination of coating were obvious under scanning electron microscopy observations. Conclusion: From the standpoint of friction, SIC brackets may serve well, even better than SS brackets, in sliding mechanics. The coating layer of the archwires may delaminate and lost, causing an impediment to tooth movement. PMID:29238380
Ghazal, Abdul Razzak A; Hajeer, Mohammad Y; Al-Sabbagh, Rabab; Alghoraibi, Ibrahim; Aldiry, Ahmad
2015-01-01
This study aimed to compare superelastic and heat-activated nickel-titanium orthodontic wires' surface morphology and potential release of nickel ions following exposure to oral environment conditions. Twenty-four 20-mm-length distal cuts of superelastic (NiTi Force I®) and 24 20-mm-length distal cuts of heat-activated (Therma-Ti Lite®) nickel-titanium wires (American Orthodontics, Sheboygan, WI, USA) were divided into two equal groups: 12 wire segments left unused and 12 segments passively exposed to oral environment for 1 month. Scanning electron microscopy and atomic force microscopy were used to analyze surface morphology of the wires which were then immersed in artificial saliva for 1 month to determine potential nickel ions' release by means of atomic absorption spectrophotometer. Heat-activated nickel-titanium (NiTi) wires were rougher than superelastic wires, and both types of wires released almost the same amount of Ni ions. After clinical exposure, more surface roughness was recorded for superelastic NiTi wires and heat-activated NiTi wires. However, retrieved superelastic NiTi wires released less Ni ions in artificial saliva after clinical exposure, and the same result was recorded regarding heat-activated wires. Both types of NiTi wires were obviously affected by oral environment conditions; their surface roughness significantly increased while the amount of the released Ni ions significantly declined.
Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires.
Geramy, Allahyar; Hooshmand, Tabassom; Etezadi, Tahura
2017-09-01
The friction between the brackets and orthodontic wire during sliding mechanics inflicts difficulties such as decreasing the applied force and tooth movement and also the loss of anchorage. Therefore, many studies have focused on the factors that affect the friction. The purpose of this study was to assess the effect of 0.05% sodium fluoride mouthwash on the friction between orthodontic brackets and wire. Four types of orthodontic wires including rectangular standard stainless steel (SS), titanium molybdenum alloy (TMA), nickel-titanium (NiTi) and copper-nickel-titanium (Cu-NiTi) were selected. In each group, half of the samples were immersed in 0.05% sodium fluoride mouthwash and the others were immersed in artificial saliva for 10 hours. An elastomeric ligature was used for ligating the wires to brackets. The frictional test was performed in a universal testing machine at the speed of 10 mm/minute. Two-way ANOVA was used for statistical analysis of the friction rate. The friction rate was significantly higher after immersion in 0.05% sodium fluoride mouthwash in comparison with artificial saliva (P=0.00). Cu-NiTi wire showed the highest friction value followed by TMA, NiTi and SS wires. According to the results of the current study, 0.05% sodium fluoride mouthwash increased the frictional characteristics of all the evaluated orthodontic wires.
Investigation on the Tribological Behavior and Wear Mechanism of Five Different Veneering Porcelains
Min, Jie; Zhang, Qianqian; Qiu, Xiaoli; Zhu, Minhao; Yu, Haiyang; Gao, Shanshan
2015-01-01
Objectives The primary aim of this research was to investigate the wear behavior and wear mechanism of five different veneering porcelains. Methods Five kinds of veneering porcelains were selected in this research. The surface microhardness of all the samples was measured with a microhardness tester. Wear tests were performed on a ball-on-flat PLINT fretting wear machine, with lubrication of artificial saliva at 37°C. The friction coefficients were recorded by the testing system. The microstructure features, wear volume, and damage morphologies were recorded and analyzed with a confocal laser scanning microscope and a scanning electron microscope. The wear mechanism was then elucidated. Results The friction coefficients of the five veneering porcelains differ significantly. No significant correlation between hardness and wear volume was found for these veneering porcelains. Under lubrication of artificial saliva, the porcelain with higher leucite crystal content exhibited greater wear resistance. Additionally, leucite crystal size and distribution in glass matrix influenced wear behavior. The wear mechanisms for these porcelains were similar: abrasive wear dominates the early stage, whereas delamination was the main damage mode at the later stage. Furthermore, delamination was more prominent for porcelains with larger crystal sizes. Significance Wear compatibility between porcelain and natural teeth is important for dental restorative materials. Investigation on crystal content, size, and distribution in glass matrix can provide insight for the selection of dental porcelains in clinical settings. PMID:26368532
Influence of the casting processing route on the corrosion behavior of dental alloys.
Galo, Rodrigo; Rocha, Luis Augusto; Faria, Adriana Claudia; Silveira, Renata Rodrigues; Ribeiro, Ricardo Faria; de Mattos, Maria da Gloria Chiarello
2014-12-01
Casting in the presence of oxygen may result in an improvement of the corrosion performance of most alloys. However, the effect of corrosion on the casting without oxygen for dental materials remains unknown. The aim of this study was to investigate the influence of the casting technique and atmosphere (argon or oxygen) on the corrosion behavior response of six different dental casting alloys. The corrosion behavior was evaluated by electrochemical measurements performed in artificial saliva for the different alloys cast in two different conditions: arc melting in argon and oxygen-gas flame centrifugal casting. A slight decrease in open-circuit potential for most alloys was observed during immersion, meaning that the corrosion tendency of the materials increases due to the contact with the solution. Exceptions were the Co-based alloys prepared by plasma, and the Co-Cr-Mo and Ni-Cr-4Ti alloys processed by oxidized flame, in which an increase in potential was observed. The amount of metallic ions released into the artificial saliva solution during immersion was similar for all specimens. Considering the pitting potential, a parameter of high importance when considering the fluctuating conditions of the oral environment, Co-based alloys show the best performance in comparison with the Ni-based alloys, independent of the processing route. Copyright © 2014 Elsevier B.V. All rights reserved.
Corrosion of dental alloys in artificial saliva with Streptococcus mutans
Lu, Chunhui; Zheng, Yuanli; Zhong, Qun
2017-01-01
A comparative study of the corrosion resistance of CoCr and NiCr alloys in artificial saliva (AS) containing tryptic soy broth (Solution 1) and Streptococcus mutans (S. mutans) species (Solution 2) was performed by electrochemical methods, including open circuit potential measurements, impedance spectroscopy, and potentiodynamic polarization. The adherence of S. mutans to the NiCr and CoCr alloy surfaces immersed in Solution 2 for 24 h was verified by scanning electron microscopy, while the results of electrochemical impedance spectroscopy confirmed the importance of biofilm formation for the corrosion process. The R(QR) equivalent circuit was successfully used to fit the data obtained for the AS mixture without S. mutans, while the R(Q(R(QR))) circuit was found to be more suitable for describing the biofilm properties after treatment with the AS containing S. mutans species. In addition, a negative shift of the open circuit potential with immersion time was observed for all samples regardless of the solution type. Both alloys exhibited higher charge transfer resistance after treatment with Solution 2, and lower corrosion current densities were detected for all samples in the presence of S. mutans. The obtained results suggest that the biofilm formation observed after 24 h of exposure to S. mutans bacteria might enhance the corrosion resistance of the studied samples by creating physical barriers that prevented oxygen interactions with the metal surfaces. PMID:28350880
Proteomic Analysis of Saliva Identifies Potential Biomarkers for Orthodontic Tooth Movement
Ellias, Mohd Faiz; Zainal Ariffin, Shahrul Hisham; Karsani, Saiful Anuar; Abdul Rahman, Mariati; Senafi, Shahidan; Megat Abdul Wahab, Rohaya
2012-01-01
Orthodontic treatment has been shown to induce inflammation, followed by bone remodelling in the periodontium. These processes trigger the secretion of various proteins and enzymes into the saliva. This study aims to identify salivary proteins that change in expression during orthodontic tooth movement. These differentially expressed proteins can potentially serve as protein biomarkers for the monitoring of orthodontic treatment and tooth movement. Whole saliva from three healthy female subjects were collected before force application using fixed appliance and at 14 days after 0.014′′ Niti wire was applied. Salivary proteins were resolved using two-dimensional gel electrophoresis (2DE) over a pH range of 3–10, and the resulting proteome profiles were compared. Differentially expressed protein spots were then identified by MALDI-TOF/TOF tandem mass spectrometry. Nine proteins were found to be differentially expressed; however, only eight were identified by MALDI-TOF/TOF. Four of these proteins—Protein S100-A9, immunoglobulin J chain, Ig alpha-1 chain C region, and CRISP-3—have known roles in inflammation and bone resorption. PMID:22919344
NASA Astrophysics Data System (ADS)
Uzer, B.; Birer, O.; Canadinc, D.
2017-09-01
Dissolution-reformation cycle of the passive oxide layer on the nickel-titanium (NiTi) orthodontic archwires was investigated, which has recently been recognized as one of the key parameters dictating the biocompatibility of archwires. Specifically, commercially available NiTi orthodontic archwires were immersed in artificial saliva solutions of different pH values (2.3, 3.3, and 4.3) for four different immersion periods: 1, 7, 14, and 30 days. Characterization of the virgin and tested samples revealed that the titanium oxide layer on the NiTi archwire surfaces exhibit a dissolution-reformation cycle within the first 14 days of the immersion period: the largest amount of Ni ion release occurred within the first week of immersion, while it significantly decreased during the reformation period from day 7 to day 14. Furthermore, the oxide layer reformation was catalyzed on the grooves within the peaks and valleys due to relatively larger surface energy of these regions, which eventually decreased the surface roughness significantly within the reformation period. Overall, the current results clearly demonstrate that the analyses of dissolution-reformation cycle of the oxide layer in orthodontic archwires, surface roughness, and ion release behavior constitute utmost importance in order to ensure both the highest degree of biocompatibility and an efficient medical treatment.
Bioactivity tests of calcium phosphates with variant molar ratios of main components.
Pluta, Klaudia; Sobczak-Kupiec, Agnieszka; Półtorak, Olga; Malina, Dagmara; Tyliszczak, Bożena
2018-03-09
Calcium phosphates constitute attractive materials of biomedical applications. Among them particular attention is devoted to bioactive hydroxyapatite (HAp) and bioresorbable tricalcium phosphate (TCP) that possess ability to bind to living bones and can be used clinically as important bone substitutes. Notably, in vivo bone bioactivity can be predicted from apatite formation of bone immersed in SBF fluids. Thus, analyses of behavior of calcium phosphates immersed in various bio fluids are of great importance. Recently, stoichiometric HAp and TCP structures have been widely studied, whereas only limited number of publications have been devoted to analyses of nonstoichiometric calcium phosphates. Here, we report physicochemical analysis of natural and synthetic phosphates with variable Ca/P molar ratios. Subsequently attained structures were subjected to incubation in either artificial saliva or Ringer's fluids. Both pH and conductivity of such fluids were determined before and after incubation. Furthermore, the influence of the Ca/P values on such parameters was exemplified. Physicochemical analysis of received materials was performed by XRD and FT-IR characterization techniques. Their potential antibacterial activity and behavior in the presence of infectious microorganisms as Escherichia coli and Staphylococcus aureus was also evaluated. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2018. © 2018 Wiley Periodicals, Inc.
Morott, Joseph T.; Pimparade, Manjeet; Park, Jun-Bom; Worley, Chelsea P.; Majumdar, Soumyajit; Lian, Zhuoyang; Pinto, Elanor; Bi, Yunxia; Durig, Thomas; Repka, Michael A.
2015-01-01
The primary aim of this research was to produce successfully taste masked formulations of Sildenafil Citrate (SC) using hot-melt extrusion (HME) technology. Multiple screw configurations and polymeric carriers were evaluated for their effects on taste masking efficiency, which was assessed by both E-tongue analysis and in vitro dissolution in simulated salivary fluid (SSF, pH 6.8 artificial saliva). The screw configurations were further assessed for their effects on the morphology of the API using PXRD, FT-IR and mid-infrared chemical imaging. It was determined that the screw configuration had a profound effect on the taste masking efficiency of the formulations as a result of altering the physical state of the API. Selected extruded formulations using ethylcellulose (EC) with a pore former were further formulated into orally disintegrating tablets (ODTs), which were optimized by varying the grade and percentage of the superdisintegrant used. An optimized disintegration time of approximately 8 seconds was achieved. The final ODT formulation exhibited excellent taste masking properties with over 85% drug release in gastric media as well as physical tablet properties. Interestingly, friability, which tends to be a common concern when formulating ODTs, was well within the acceptable limits (<1%) for common tablets. PMID:25410968
Release of beryllium from mineral ores in artificial lung and skin surface fluids.
Duling, Matthew G; Stefaniak, Aleksandr B; Lawrence, Robert B; Chipera, Steve J; Virji, M Abbas
2012-06-01
Exposure to some manufactured beryllium compounds via skin contact or inhalation can cause sensitization. A portion of sensitized persons who inhale beryllium may develop chronic beryllium disease (CBD). Little is understood about exposures to naturally occurring beryllium minerals. The purpose of this study was to assess the bioaccessibility of beryllium from bertrandite ore. Dissolution of bertrandite from two mine pits (Monitor and Blue Chalk) was evaluated for both the dermal and inhalation exposure pathways by determining bioaccessibility in artificial sweat (pH 5.3 and pH 6.5), airway lining fluid (SUF, pH 7.3), and alveolar macrophage phagolysosomal fluid (PSF, pH 4.5). Significantly more beryllium was released from Monitor pit ore than Blue Chalk pit ore in artificial sweat buffered to pH 5.3 (0.88 ± 0.01% vs. 0.36 ± 0.00%) and pH 6.5 (0.09 ± 0.00% vs. 0.03 ± 0.01%). Rates of beryllium released from the ores in artificial sweat were faster than previously measured for manufactured forms of beryllium (e.g., beryllium oxide), known to induce sensitization in mice. In SUF, levels of beryllium were below the analytical limit of detection. In PSF, beryllium dissolution was biphasic (initial rapid diffusion followed by latter slower surface reactions). During the latter phase, dissolution half-times were 1,400 to 2,000 days, and rate constants were ~7 × 10(-10) g/(cm(2)·day), indicating that bertrandite is persistent in the lung. These data indicate that it is prudent to control skin and inhalation exposures to bertrandite dusts.
Relating rheology and tribology of commercial dairy colloids to sensory perception.
Laguna, Laura; Farrell, Grace; Bryant, Michael; Morina, Ardian; Sarkar, Anwesha
2017-02-22
This study aims to investigate the relationship between rheological and tribological properties of commercial full fat and fat-free/low fat versions of liquid and soft solid colloidal systems (milk, yoghurt, soft cream cheese) with their sensory properties. Oscillatory measurements (strain, frequency), flow curves and tribological measurements (lubrication behaviour using Stribeck analysis) were conducted. Oral condition was mimicked using artificial saliva at 37 ○ C. Discrimination test was conducted by 63 untrained consumers, followed by a qualitative questionnaire. Consumers significantly discriminated the fat-free/low fat from the full fat versions (p < 0.01) in all product classes, with most common verbatim used being "creamy", "sweet" for the full fat versus "watery", "sour" for the fat-free samples. Flow behaviour of both versions of milk showed overlapping trends with no significant differences identified both in absence and presence of saliva (p > 0.05). Full fat and fat free yoghurts had similar yielding behaviour and elastic modulus (G'), even in simulated oral conditions. However, in case of soft cream cheese, the full fat version had a moderately higher G' than the low fat counterpart. Even in presence of artificial saliva, there was slight but significant difference in viscoelasticity between the cream cheese variants depending on fat content (p < 0.05). Stribeck curve analyses showed that at lower entrainment velocities (1-100 mm s -1 ), both full fat yoghurt and soft cream cheese exhibited a significantly lower traction coefficient when compared to fat-free/low fat versions (p < 0.05), which might be attributed to the lubricating effect of the coalesced fat droplets. Surprisingly, whole and skim milks showed no significant difference in traction coefficients irrespective of the entrainment speeds (p > 0.05). Results suggest that sensory distinction between fat-free and full fat versions, particularly in semi-solid systems could be better predicted by lubrication data as compared to bulk rheology.
NASA Astrophysics Data System (ADS)
Teraji, T.; Arakaki, T.; Suzuka, T.
2012-12-01
Use of artificial sweeteners in beverages and food has been rapidly increasing because of their non-calorie nature. In Japan, aspartame, acesulfame K and sucralose are among the most widely used artificial sweeteners. Because the artificial sweeteners are not metabolized in human bodies, they are directly excreted into the environment without chemical transformations. We initiated a study to better understand the fate of artificial sweeteners in the marine environment. The hydroxyl radical (OH), the most potent reactive oxygen species, reacts with various compounds and determines the environmental oxidation capacity and the life-time of many compounds. The steady-state OH concentration and the reaction rate constants between the compound and OH are used to estimate the life-time of the compound. In this study, we determine the bimolecular rate constants between aspartame, acefulfame K and saccharin and OH at various pH and temperature conditions using a competition kinetics technique. We use hydrogen peroxide as a photochemical source of OH. Bimolecular rate constant we obtained so far for aspartame was (2.6±1.2)×109 M-1 s-1 at pH = 3.0 and (4.9±2.3)×109 M-1 s-1 at pH = 5.5. Little effect was seen by changing the temperatures between 15 and 40 oC. Activation energy (Ea) was calculated to be -1.0 kJ mol-1 at pH = 3.0, +8.5 kJ mol-1 at pH = 5.5, which could be regarded as zero. We will report bimolecular rate constants at different pHs and temperatures for acesulfame K and saccharin, as well. Possible reaction by-products for aspartame will be also reported. We will further discuss the fate of aspartame in the coastal environment.
Botelho, Juliana Nunes; Villegas-Salinas, Mario; Troncoso-Gajardo, Pía; Giacaman, Rodrigo Andrés; Cury, Jaime Aparecido
2016-05-20
Sucrose is the most cariogenic dietary carbohydrate and starch is considered non-cariogenic for enamel and moderately cariogenic for dentine. However, the cariogenicity of the combination of starch and sucrose remains unclear. The aim of this study was to evaluate the effect of this combination on Streptococcus mutans biofilm composition and enamel and dentine demineralization. Biofilms of S. mutans UA159 were grown on saliva-coated enamel and dentine slabs in culture medium containing 10% saliva. They were exposed (8 times/day) to one of the following treatments: 0.9% NaCl (negative control), 1% starch, 10% sucrose, or 1% starch and 10% sucrose (starch + sucrose). To simulate the effect of human salivary amylase on the starch metabolization, the biofilms were pretreated with saliva before each treatment and saliva was also added to the culture medium. Acidogenicity of the biofilm was estimated by evaluating (2 times/day) the culture medium pH. After 4 (dentine) or 5 (enamel) days of growth, biofilms (n = 9) were individually collected, and the biomass, viable microorganism count, and polysaccharide content were quantified. Dentine and enamel demineralization was assessed by determining the percentage of surface hardness loss. Biofilms exposed to starch + sucrose were more acidogenic and caused higher demineralization (p < 0.0001) on either enamel or dentine than those exposed to each carbohydrate alone. The findings suggest that starch increases the cariogenic potential of sucrose.
Diverio, S; Guelfi, G; Barbato, O; Di Mari, W; Egidi, M G; Santoro, M M
2015-01-01
Exercise has been shown to increase mRNA expression of a growing number of genes. The aim of this study was to assess if mRNA expression of the metabolism- and oxidative stress-related genes GLUT4 (glucose transporter 4), COX2 (cyclooxygenase 2), SOD1 (superoxide dismutase 1) and HSP70 (heat shock protein 70) in saliva changes following acute exercise stress in dogs. For this purpose, 12 avalanche dogs of the Italian Military Force Guardia di Finanza were monitored during simulation of a search for a buried person in an artificial avalanche area. Rectal temperature (RT) and saliva samples were collected the day before the trial (T0), immediately after the descent from a helicopter at the onset of a simulated avalanche search and rescue operation (T1), after the discovery of the buried person (T2) and 2 h later (T3). Expressions of GLUT4, SOD1, COX2 and HSP70 were measured by real-time PCR. The simulated avalanche search and rescue operation was shown to exert a significant effect on RT, as well as on the expression of all metabolism- and oxidative stress-related genes investigated, which peaked at T2. The observed expression patterns indicate an acute exercise stress-induced upregulation, as confirmed by the reductions in expression at T3. Moreover, our findings indicate that saliva is useful for assessing metabolism- and oxidative stress-related genes without the need for restraint, which could affect working dog performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vincent, S.; Daiwile, A.; Devi, S. S.
Metallic glasses are a potential and compatible implant candidate for biomedical applications. In the present investigation, a comparative study between novel Zr 55Co 30Ti 15 and Cu 60Zr 20Ti 20 metallic glasses is carried out to evaluate in vitro biocompatibility using simulated body fluids. The bio-corrosion behavior of Zr- and Cu-based metallic glasses in different types of artificial body fluids such as artificial saliva solution, phosphate-buffered saline solution, artificial blood plasma solution, and Hank’s balanced saline solution is evaluated using potentiodynamic polarization studies at a constant body temperature of 310.15 K (37 °C). Surface morphology of samples after bio-corrosion experimentsmore » was observed by scanning electron microscopy. In vitro cytotoxicity test on glassy alloys were performed using human osteosarcoma cell line as per 10993-5 guidelines from International Organization for Standardization. As a result, the comparative study between Zr- and Cu-based glassy alloys provides vital information about the effect of elemental composition on biocompatibility of metallic glasses.« less
Disposition of acetaminophen in milk, saliva, and plasma of lactating women.
Berlin, C M; Yaffe, S J; Ragni, M
1980-01-01
Acetaminophen (APAP) is a widely used analgesic and antipyretic, but its disposition in human milk has not yet been reported. Twelve nursing mothers (nursing two to 22 months) were given a single 650-mg peroral dose of APAP. Simultaneous saliva and milk samples were collected at zero, 1/4, 1/2, 3/4, 1, 2, 3, 5, 8, 12, and 24 hours after maternal dosing. In two mothers, plasma samples were also obtained at several points during the first six hours. Single voided urine samples were collected from the infants three to five hours after maternal dosing (two hours after nursing at peak maternal milk levels). All samples were assayed for APAP by high pressure liquid chromatography (HPCL) using a mobile phase of 0.05 M Na acetate pH 4.0-acetonitrile (93:10) with n-butyryl-p-aminophenol as the internal standard. APAP appeared in saliva and milk in the 1/4-hour samples; peak level (10-15 micrograms/ml) were achieved by one to two hours. Saliva/milk ratios during the elimination phase ranged from 0.7 to 1.1, with most values between 0.8 and 0.9. In two patients studied, saliva/plasma ratios were 0.9 to 1.0. Elimination phase t 1/2 (calculated from beta) ranged from 1.35 to 3.50 (x = 2.28 +/- SD 0.69) hours for milk, and from 1.72 to 3.30 (x = 2.48 +/- 0.56) hours for saliva. There was close agreement between saliva t 1/2 and milk t 1/2 for each patient. Assuming each infant ingested 90 ml milk at 3, 6, and 9 hours after maternal ingestion of APAP, the amount of APAP available for ingestion ranged from 0.28 to 1.51 mg (x = 0.88 +/- 0.31) or from 0.04% to 0.23% (x = 0.14 +/- 0.04) of maternal dose. Neither APAP nor metabolite was detected in nursing infants' urine. Maternal APAP ingestion in usual analgesic doses does not appear to present a risk to the nursing infant.
Passos, Vanara Florêncio; Rodrigues, Lidiany Karla Azevedo; Santiago, Sérgio Lima
2018-02-01
To evaluate, in vitro, the effect of Mg(OH) 2 dentifrice, and the influence of the number of experimental days, on the extrinsic (citric acid -CA) and intrinsic (hydrochloric acid -HCl) enamel erosion models. Human enamel slabs were selected according to surface hardness and randomly assigned to 3 groups (n=9) as follows: non-fluoridated (negative control), NaF (1450ppm F- positive control) and Mg(OH) 2 (2%) dentifrices. The slabs were daily submitted to a 2-h period of pellicle formation and, over a period of 5days, submitted to cycles (3×/day) of erosive challenge (CA 0.05M, pH=3.75 or HCl 0.01M, pH=2 for 30s), treatment (1min -1:3w/w of dentifrice/distilled water) and remineralization (artificial saliva/120min). Enamel changes were determined by surface hardness loss (SHL) for each day and mechanical profilometry analysis. Data were analyzed by two-way ANOVA followed by Tukey's test to % SHL and one-way ANOVA to profilometry (p<0.05). The number of experimental days influenced the erosion process for the two types of erosion models (p<0.001). Mg(OH) 2 -containing dentifrices were effective in reducing enamel extrinsic acid erosion as determined by % SHL (p<0.001) when compared to the control group, being better than positive control (p<0.001); however, the dentifrices were not effective for the intrinsic model (p=0.295). With regards to surface wear, no statistically significant differences were found among the groups for CA (p=0.225) and HCl (p=0.526). The findings suggest that Mg(OH) 2 dentifrices might protect enamel against slight erosion, but protection was not effective for stronger acid erosion. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effect of NaF and TiF(4) varnish and solution on bovine dentin erosion plus abrasion in vitro.
Magalhães, Ana Carolina; Levy, Flávia Mauad; Rizzante, Fábio A; Rios, Daniela; Buzalaf, Marília Afonso Rabelo
2012-03-01
This in vitro study aimed to analyze the effect of TiF(4) compared to NaF varnishes and solutions, to protect against dentin erosion associated with abrasion. Bovine dentin specimens were pre-treated with NaF-Duraphat (2.26% F), NaF/CaF(2)-Duofluorid (5.63% F), experimental-NaF (2.45% F), experimental-TiF(4) (2.45% F) and placebo varnishes; NaF (2.26% F) and TiF(4) (2.45% F) solutions. Controls remained untreated. The erosive pH cycling was performed using a soft drink (pH 2.6) 4 × 90 s/day and the toothbrushing-abrasion 2 × 10 s/day, in vitro for 5 days. Between the challenges, the specimens were exposed to artificial saliva. Dentin tissue loss was measured profilometrically (μm). ANOVA/Tukey's test showed that all fluoridated varnishes (Duraphat, 7.5 ± 1.1; Duofluorid, 6.8 ± 1.1; NaF, 7.2 ± 1.9; TiF(4), 6.5 ± 1.0) were able to significantly reduce dentin tissue loss (40.7% reduction compared to control) when compared to placebo varnish (11.2 ± 1.3), control (11.8 ± 1.7) and fluoridated (NaF, 9.9 ± 1.8; TiF(4), 10.3 ± 2.1) solutions (p < 0.0001), which in turn did not significantly differ from each other. All fluoridated varnishes, but not the solutions, had a similar performance and a good potential to reduce dentin tissue loss under mild erosive and abrasive conditions in vitro. Risk patients for erosion and abrasion, especially those with exposed dentin, should benefit from this clinical preventive measure. Further research has to confirm this promising result in the clinical situation.
Koopman, Jessica E; Röling, Wilfred F M; Buijs, Mark J; Sissons, Christopher H; ten Cate, Jacob M; Keijser, Bart J F; Crielaard, Wim; Zaura, Egija
2015-02-01
Dysbiosis induced by low pH in the oral ecosystem can lead to caries, a prevalent bacterial disease in humans. The amino acid arginine is one of the pH-elevating agents in the oral cavity. To obtain insights into the effect of arginine on oral microbial ecology, a multi-plaque "artificial mouth" (MAM) biofilm model was inoculated with saliva from a healthy volunteer and microcosms were grown for 4 weeks with 1.6 % (w/v) arginine supplement (Arginine) or without (Control), samples were taken at several time-points. A cariogenic environment was mimicked by sucrose pulsing. The bacterial composition was determined by 16S rRNA gene amplicon sequencing, the presence and amount of Candida and arginine deiminase system genes arcA and sagP by qPCR. Additionally, ammonium and short-chain fatty acid concentrations were determined. The Arginine microcosms were dominated by Streptococcus, Veillonella, and Neisseria and remained stable in time, while the composition of the Control microcosms diverged significantly in time, partially due to the presence of Megasphaera. The percentage of Candida increased 100-fold in the Control microcosms compared to the Arginine microcosms. The pH-raising effect of arginine was confirmed by the pH and ammonium results. The abundances of sagP and arcA were highest in the Arginine microcosms, while the concentration of butyrate was higher in the Control microcosms. We demonstrate that supplementation with arginine serves a health-promoting function; it enhances microcosm resilience toward acidification and suppresses outgrowth of the opportunistic pathogen Candida. Arginine facilitates stability of oral microbial communities and prevents them from becoming cariogenic.
Frasseto, F; Parisotto, T M; Peres, R C R; Marques, M R; Line, S R P; Nobre Dos Santos, M
2012-01-01
This study aimed to determine the activity of carbonic anhydrase isoenzyme VI (CAVI) in the saliva of preschool children with caries and to investigate the relationship between caries and salivary CAVI activity, salivary flow rate and biofilm pH before and after a 20% sucrose rinse. Thirty preschool children aged 45.3-80.3 months were divided into two groups: a caries-free group and a caries group. Clinical examinations were conducted by one examiner (κ = 0.95) according to WHO criteria (dmfs) and early caries lesions. From each subject, CAVI activity, salivary flow rate and plaque pH were determined before and after a sucrose rinse. The results were submitted to Wilcoxon, Mann-Whitney and Spearman correlation tests (α = 0.05). The results showed that prerinse CAVI activity and its variation were higher in the saliva from caries children than from caries-free children. No difference was found between the two groups in postrinse salivary CAVI activity. After rinsing, biofilm pH differences were lower in both groups (p = 0.0012 and p = 0.0037 for the caries and caries-free groups, respectively). Also, after the sucrose rinse, salivary flow rate significantly increased in caries and caries-free groups (p = 0.0003, p = 0.0037). The variation of salivary CAVI activity was negatively correlated with caries (r = -0.501, p = 0.005). Child's age showed a positive correlation with caries (r = 0.456, p = 0.011). These results suggest that variation of salivary CAVI activity and child's age are associated with dental caries in preschool children. Copyright © 2012 S. Karger AG, Basel.
Atara, Achyuta G.; Manjusha, R.; Shukla, Vinay J.; Vaghela, Dharmendra B.; Rooparalia, Brijesh
2014-01-01
Background: Dental caries is the most common complaint encountered in clinical practice. Virtually every adult in the world has experience of dental caries. It affects almost 80% of the population. It is now being viewed in dual perspective- “caries as a disease” and “caries as a lesion”. Aims: To evaluate the efficacy of Triphaladi Gandusha for its anti-caries activity and improvement in Oral Hygiene Index in high risk patients of dental caries and to compare the efficacy of prevalent method of mouth rinsing and classical method of Gandusha. Materials and Methods: The study was conducted in 40 patients, 20 in each Group-1 and 2. Group -1 was given prepared Triphaladi mouthwash (mouth rinse) while Group-2 was given Triphaladi Kwath for Gandusha (retention). Results: The effect of treatment was assessed by subjective and objective parameters (like salivary pH, buffering capacity and microbial count). Triphaladi Gandusha (retention) in Group - 2 provided better results in the improvement of Ruja (toothache), Dantaharsha (tooth sensitivity), Sarambha (inflammation), pH of saliva, microbial count in salivary sample. And Triphaladi Mouthwash in Group - 1 provided better results in Srava (discharge), bad breath, pH of saliva and buffering capacity of salivary sample. There was no improvement in Chidrata (cavity formation), Krishnata (discoloration) and Chaladanta (mobility) with Triphaladi Gandusha and mouthwash. Conclusion: Study concluded that although both groups were effective, but Gandusha group patients’ got better relief in subjective symptoms compared to mouthwash group. PMID:25364198
Atara, Achyuta G; Manjusha, R; Shukla, Vinay J; Vaghela, Dharmendra B; Rooparalia, Brijesh
2014-01-01
Dental caries is the most common complaint encountered in clinical practice. Virtually every adult in the world has experience of dental caries. It affects almost 80% of the population. It is now being viewed in dual perspective- "caries as a disease" and "caries as a lesion". To evaluate the efficacy of Triphaladi Gandusha for its anti-caries activity and improvement in Oral Hygiene Index in high risk patients of dental caries and to compare the efficacy of prevalent method of mouth rinsing and classical method of Gandusha. The study was conducted in 40 patients, 20 in each Group-1 and 2. Group -1 was given prepared Triphaladi mouthwash (mouth rinse) while Group-2 was given Triphaladi Kwath for Gandusha (retention). The effect of treatment was assessed by subjective and objective parameters (like salivary pH, buffering capacity and microbial count). Triphaladi Gandusha (retention) in Group - 2 provided better results in the improvement of Ruja (toothache), Dantaharsha (tooth sensitivity), Sarambha (inflammation), pH of saliva, microbial count in salivary sample. And Triphaladi Mouthwash in Group - 1 provided better results in Srava (discharge), bad breath, pH of saliva and buffering capacity of salivary sample. There was no improvement in Chidrata (cavity formation), Krishnata (discoloration) and Chaladanta (mobility) with Triphaladi Gandusha and mouthwash. Study concluded that although both groups were effective, but Gandusha group patients' got better relief in subjective symptoms compared to mouthwash group.
Shih, Yu-En; Lin, Yu-Chih; Chung, Tse-Yu; Liu, Mei-Chun; Chen, Guan-Heng; Wu, Chia-Chang; Tzen, Jason T C
2017-10-01
Astringency, a sensory characteristic of food and beverages rich in polyphenols, mainly results from the formation of complexes between polyphenols and salivary proteins, causing a reduction of the lubricating properties of saliva. To develop an in vitro assay to estimate the astringency of oolong tea infusion, artificial oil bodies were constituted with sesame oil sheltered by a modified caleosin fused with histatin 3, one of the human salivary small peptides. Aggregation of artificial oil bodies was induced when they were mixed with oolong tea infusion or its major polyphenolic compound, (-)-epigallocatechin gallate (EGCG) of 100μM as observed in light microscopy. The aggregated artificial oil bodies gradually floated on top of the solution and formed a visible milky layer whose thickness was in proportion to the concentrations of tea infusion. This assay system was applied to test four different oolong tea infusions with sensory astringency corresponding to their EGCG contents. The result showed that relative astringency of the four tea infusions was correlated to the thickness of floated artificial oil bodies, and could be estimated according to the standard curve generated by simultaneously observing a serial dilution of the tea infusion with the highest astringency. Copyright © 2016. Published by Elsevier B.V.
Smartphone based non-invasive salivary glucose biosensor.
Soni, Anuradha; Jha, Sandeep Kumar
2017-12-15
The present work deals with the development of a non-invasive optical glucose biosensor using saliva samples and a smartphone. The sensor was fabricated with a simple methodology by immobilization of Glucose oxidase enzyme along with a pH responsive dye on a filter paper based strip. The strip changes color upon reaction with glucose present in saliva and the color changes were detected using a smartphone camera through RGB profiling. This standalone biosensor showed good sensitivity and low interference while operating within 20 s response time. We used various means for improvements such as the use of slope method instead of differential response; use of a responsive pH indicator and made numerous tweaks in the smartphone app. Calibration with spiked saliva samples with slopes for (R + G + B) pixels revealed an exponentially increasing calibration curve with a linear detection range of 50-540 mg/dL, sensitivity of 0.0012 pixels sec -1 /mg dL -1 and LOD of 24.6 mg/dL. The biosensor was clinically validated on both healthy and diabetic subjects divided into several categories based on sex, age, diabetic status etc. and correlation between blood and salivary glucose has been established for better standardization of the sensor. Correlation of 0.44 was obtained between blood and salivary glucose in healthy individuals whereas it was 0.64 and 0.94 in case of prediabetic and diabetic patients respectively. The developed biosensor has the potential to be used for mass diagnosis of diabetes especially in such areas where people remain prohibited from routine analysis due to high healthcare cost. Apart from that, a smartphone would be the only device the user needs for this measurement, along with a disposable low cost test strip. Copyright © 2017 Elsevier B.V. All rights reserved.
Hyaluronidase activity in the salivary glands of tabanid flies.
Volfova, Vera; Tothova, Viktorie; Volf, Petr
2016-06-01
Tabanids are haematophagous insects that act as biological and mechanical vectors of various diseases, including viruses, bacteria and parasites. The saliva of these insects contains strong anticoagulant and vasodilatory activities as well as immunoregulatory peptides. Here we demonstrate pronounced hyaluronidase (hyase) activity in ten tabanid species of the genera Chrysops, Haematopota, Hybomitra and Tabanus. Compared to other haematophagous insects, the ability of tabanid hyases to hydrolyze hyaluronic acid (HA) is extremely high, for example the enzyme activity of Hybomitra muehlfeldi was found to be 32-fold higher than the salivary hyase activity of the sand fly Phlebotomus papatasi. Hyases of all ten tabanid species tested also cleaved chondroitin sulfate A, another glycosaminoglycan present in the extracellular matrix of vertebrates. The pH optimum of the enzyme activity was measured in eight tabanid species; the hyase of Haemopota pluvialis was the only one with optimum at pH 4.0, while in the other seven species the activity optimum was at 5.0. SDS PAGE zymography showed the monomeric character of the enzymes in all tabanid species tested. Under non-reducing conditions the activities were visible as single bands with estimated MW between 35 and 52 kDa. The very high hyaluronidase activity in tabanid saliva might be related to their aggressive biting behavior as well as to their high efficiency as mechanical vectors. As they are supposedly involved in the enlargement of feeding hematomas, hyases might contribute to the mechanical transmission of pathogens. Pathogens present in vector mouthparts are co-inoculated into the vertebrate host together with saliva and may benefit from increased tissue permeability and the immunomodulatory activity of the salivary hyase. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Reduced salivary flow and colonization by mutans streptococci in children with Down syndrome
Areias, Cristina; Sampaio-Maia, Benedita; de Lurdes Pereira, Maria; Azevedo, Álvaro; Melo, Paulo; Andrade, Casimiro; Scully, Crispian
2012-01-01
OBJECTIVES: Although individuals with Down syndrome have considerable oral disease, the prevalence of dental caries in this group is low. The present study aimed to compare known risk factors for dental caries development in children with Down syndrome and a matched population (siblings). In both populations, the number of acidogenic microorganisms, such as mutans streptococci, lactobacilli and Candida species, and the paraffin-stimulated pH, flow rate and IgA concentration in whole saliva were evaluated and compared. METHOD: Saliva was collected, and the caries index was evaluated in 45 sibling pairs aged between 6 and 18 years old. The salivary IgA concentration was determined by immunoturbidimetry. Salivary mutans streptococci, lactobacilli and Candida species were quantified on mitis salivarius agar containing bacitracin and 20% sucrose, rogosa agar supplemented with glacial acetic acid and sabouraud agar supplemented with chloramphenicol, respectively. RESULTS: Down syndrome children had a higher caries-free rate (p<0.05) and lower salivary mutans streptococci counts (p<0.03) compared to their siblings. Similar numbers of lactobacilli and Candida species were found in both groups. Salivary flow rates were 36% lower in Down syndrome children compared to their siblings (p<0.05). The salivary pH did not differ between Down syndrome children and controls. The Down syndrome children had an IgA secretion rate 29% lower than that of their siblings, but this difference was not statistically significant. CONCLUSIONS: In conclusion, the lower number of mutans streptococci in the saliva may be one of the factors contributing to the lower caries rate observed in Down syndrome children, despite evidence of hyposalivation. PMID:23018295
Steiger-Ronay, Valerie; Tektas, Sibel; Attin, Thomas; Lussi, Adrian; Becker, Klaus; Wiedemeier, Daniel B; Beyeler, Barbara; Carvalho, Thiago S
2018-06-07
The aim of this in vitro study was to investigate the impact of saliva on the abrasion of eroded enamel using two measuring methods. A total of 80 bovine enamel specimens from 20 bovine incisors were allocated to four experimental groups (n = 20 specimens per group). After baseline surface microhardness (SMH) measurements and profilometry all specimens were subjected to erosion (2 min, 1% citric acid, pH: 3.6, 37°C). SMH was determined again, and the depths of the Knoop indentations were calculated. Thereafter, specimens were incubated in human saliva (group 1 - no incubation/control, group 2 - 0.5 h, group 3 - 1 h, group 4 - 2 h) before toothbrush abrasion was performed. After final SMH measurements and profilometry, indentations were remeasured, and surface loss was calculated. SMH did not return to baseline values regardless of the length of saliva incubation. Further, an irreversible substance loss was observed for all specimens. With the indentation method, significantly (p < 0.05) more substance loss was found for controls (least square means ± standard error of 198 ± 19 nm) than for groups 2-4 (110 ± 10, 114 ± 11, and 105 ± 14 nm). Profilometric assessment showed significantly more substance loss for controls (122 ± 8 nm) than for group 4 (106 ± 5 nm). Intraclass correlation for interrater reliability between measurement methods was low (0.21, CI: 0.1-0.3), indicating poor agreement. Exposure of eroded enamel to saliva for up to 2 h could not re-establish the original SMH. The amount of measured substance loss depended on the measurement method applied. © 2018 S. Karger AG, Basel.
Factors which influence levels of selected organisms in saliva of older individuals.
Loesche, W J; Schork, A; Terpenning, M S; Chen, Y M; Stoll, J
1995-01-01
The most commonly measured bacterial parameters in saliva are the levels of the mutans group streptococci and lactobacilli, which have diagnostic implications for the incidence of dental decay. Diagnostic guidelines which are applicable to children and young adults in whom most, if not all, teeth are present and in whom the rate of stimulated saliva is almost always greater than 0.5 ml/min have been developed. Dental decay is a potential health problem of considerable magnitude among elderly individuals. In elderly individuals, missing teeth, the presence of dentures, and a reduced salivary flow could confound the interpretation of salivary levels of cariogenic bacteria. In the present study, in which saliva was collected from more than 560 elderly individuals (average age, 70 +/- 8 years), there was a significant positive relationship between the salivary levels of Streptococcus mutans and increased numbers of teeth. There was a positive association between the salivary levels of S. mutans and decay when the data were stratified for the presence of a complaint of xerostomia and the presence of dentures. However, a similar analysis indicated that lactobacilli and yeasts were more likely to be associated with decay. The various variables which could influence the bacterial counts per milliliter of saliva, e.g., independent or dependent living status, complaint of xerostomia, stimulated salivary flow, salivary pH, the presence of dentures, number of teeth, and decay, were analyzed simultaneously by using a multivariable linear model. In that analysis the number of decayed teeth was significantly associated with the presence of lactobacilli (P = 0.0001) and yeasts (P = 0.025) but not with the presence of S. mutans.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8567881
NMR Studies of the Dynamics of Nitrophorin 2 Bound to Nitric Oxide†
Muthu, Dhanasekaran; Berry, Robert E.; Zhang, Hongjun; Walker, F. Ann
2013-01-01
The Rhodnius nitrophorins are β-barrel proteins of the lipocalin fold with a heme protruding from the open end of the barrel. They are found in the saliva of the blood-sucking insect Rhodnius prolixus, which synthesizes and stores nitric oxide (NO) in the salivary glands, where NO is bound to iron. NO is released by dilution and pH rise when the insect spits its saliva into the tissues of a victim, to aid in obtaining a blood meal. In the adult insect there are four nitrophorins, NP1, NP2, NP3 and NP4. At pH 7.3, NP4 releases NO 17 times faster than does NP2, as measured by stopped-flow kinetics. A number of crystal structures of the least abundant protein, NP4, are available. These structures have been used to propose that two loops between adjacent β-strands at the front opening of the protein, the A-B and G-H loops, determine the rate of NO release. In order to learn how the protein loops contribute to release of NO for each of the nitrophorins, the dynamics of these proteins are being studied in our laboratory. In this work, the NP2-NO complex has been investigated by NMR relaxation measurements to probe the pico- to nanosecond and micro- to millisecond time scale motions at three pH values, 5.0, 6.5, and 7.3. It is found that at pH 5.0 and 6.5, NP2-NO is rigid and only a few residues in the loop regions show dynamics, while at pH 7.3 somewhat more dynamics, particularly of the A-B loop, are observed. Comparison to other lipocalins shows that all are relatively rigid, and that the dynamics of lipocalins in general are much more subtle than those of mainly α-helical proteins. PMID:24116947
Barac, Radomir; Gasic, Jovanka; Trutic, Natasa; Sunaric, Slavica; Popovic, Jelena; Djekic, Petar; Radenkovic, Goran; Mitic, Aleksandar
2015-01-01
Objective To assess the erosive potential of various soft drinks by measuring initial pH and titratable acidity (TA) and to evaluate enamel surface roughness using different exposure times. Materials and Methods The initial pH of the soft drinks (group 1: Coca-Cola; group 2: orange juice; group 3: Cedevita; group 4: Guarana, and group 5: strawberry yoghurt) was measured using a pH meter, and TA was measured by titration with NaOH. Enamel samples (n = 96), cut from unerupted human third molars, were randomly assigned to 6 groups: experimental (groups 1–5) and control (filtered saliva). The samples were exposed to 50 ml of soft drinks for 15, 30 and 60 min, 3 times daily, during 10 days. Between immersions, the samples were kept in filtered saliva. Enamel surface roughness was measured by diamond stylus profilometer using the following roughness parameters: Ra, Rq, Rz, and Ry. Data were analyzed by one-way ANOVA, Tukey's post hoc and Student-Newman-Keuls post hoc tests. Results The pH values of the soft drinks ranged from 2.52 (Guarana) to 4.21 (strawberry yoghurt). Orange juice had the highest TA, requiring 5.70 ml of NaOH to reach pH 7.0, whereas Coca-Cola required only 1.87 ml. Roughness parameters indicated that Coca-Cola had the strongest erosion potential during the 15 min of exposure, while Coca-Cola and orange juice were similar during 30- and 60-min exposures. There were no significant differences related to all exposure times between Guarana and Cedevita. Strawberry yoghurt did not erode the enamel surface regardless of the exposure time. Conclusion All of the tested soft drinks except yoghurt were erosive. Erosion of the enamel surfaces exposed to Coca-Cola, orange juice, Cedevita, and Guarana was directly proportional to the exposure time. PMID:26111496
Barac, Radomir; Gasic, Jovanka; Trutic, Natasa; Sunaric, Slavica; Popovic, Jelena; Djekic, Petar; Radenkovic, Goran; Mitic, Aleksandar
2015-01-01
To assess the erosive potential of various soft drinks by measuring initial pH and titratable acidity (TA) and to evaluate enamel surface roughness using different exposure times. The initial pH of the soft drinks (group 1: Coca-Cola; group 2: orange juice; group 3: Cedevita; group 4: Guarana, and group 5: strawberry yoghurt) was measured using a pH meter, and TA was measured by titration with NaOH. Enamel samples (n = 96), cut from unerupted human third molars, were randomly assigned to 6 groups: experimental (groups 1-5) and control (filtered saliva). The samples were exposed to 50 ml of soft drinks for 15, 30 and 60 min, 3 times daily, during 10 days. Between immersions, the samples were kept in filtered saliva. Enamel surface roughness was measured by diamond stylus profilometer using the following roughness parameters: Ra, Rq, Rz, and Ry. Data were analyzed by one-way ANOVA, Tukey's post hoc and Student-Newman-Keuls post hoc tests. The pH values of the soft drinks ranged from 2.52 (Guarana) to 4.21 (strawberry yoghurt). Orange juice had the highest TA, requiring 5.70 ml of NaOH to reach pH 7.0, whereas Coca-Cola required only 1.87 ml. Roughness parameters indicated that Coca-Cola had the strongest erosion potential during the 15 min of exposure, while Coca-Cola and orange juice were similar during 30- and 60-min exposures. There were no significant differences related to all exposure times between Guarana and Cedevita. Strawberry yoghurt did not erode the enamel surface regardless of the exposure time. All of the tested soft drinks except yoghurt were erosive. Erosion of the enamel surfaces exposed to Coca-Cola, orange juice, Cedevita, and Guarana was directly proportional to the exposure time. © 2015 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blanpied, G.D.
Trees of seedling apple (Malus domesticas borkh.) received 2.5 cm of artificial rain at pH 3.3 or 4.2, each with 0.4 or 1.4 mg Ca/liter of rain water during 7-hour periods. In the early summer period (June 19-July 10) artificial rain reduced Ca in apple leaves, but there were no significant differences due to pH or Ca concentration in the rain. Ca losses during rain treatment appeared to be recovered during 1 week holding periods after treatment. In the autumn period (September 25-October 16) the reduction in leaf Ca was greatest wih low pH, low Ca rain and least withmore » high pH, high Ca rain, which increased Ca in the leaves. K in the leaves was reduced more than Ca, but was not affected by pH or Ca in the rain during either period of observation.« less
Aksit Bıcak, Damla; Akyuz, Serap; Kıratlı, Binnur; Usta, Merve; Urganci, Nafiye; Alev, Burcin; Yarat, Aysen; Sahin, Fikrettin
2017-03-21
The oral cavity can be an extra-gastric reservoir for Helicobacter pylori (H.pylori). This can play a role in the pathogenesis of halitosis, glossitis, recurrent aphthous stomatitis, and dental caries. The present study was conducted to detect the presence of H.pylori within the dental biofilm and in saliva samples collected from children suffering from dyspepsia and children without any gastrointestinal complaints. Associations with gastric infection, halitosis, and some oral parameters were also evaluated. Seventy children (aged between 5-16) with dyspepsia were selected for the study group and control group composed of 30 healthy children without dyspepsia were also included in the study. After detailed oral and clinical examinations for oral parameters, saliva, and supragingival dental biofilm samples were collected for 16S rRNA and 23S rRNA genes detection by real-time polymerase chain reaction (RT-PCR). The presence of gastric H.pylori was evaluated in endoscopic biopsy specimens histopathologically. Halitosis was evaluated by benzoyl-DL-arginine-naphthylamid (BANA) test. Salivary S.mutans and Lactobacilli sp. counts were also carried out by commercial kits. H.pylori was histopathologically detected amongst 83% of the children with the dyspeptic condition. The detection rate of this bacteria in dental biofilm and saliva samples and halitosis were found relatively higher in the dyspeptic children rather than the control group (p < 0.01). Halitosis was not significantly different between dyspeptic children and those detected with H.pylori (p > 0.05). In the gastric H.pylori positive group with dyspepsia, DMFT/S and dmft/s numbers and plaque indices were found higher than the control group (p < 0.01). Only plaque indices of gastric H.pylori negative group with dyspepsia were found higher than the control group (p < 0.01). S.mutans and Lactobacilli sp. counts were not significantly different between gastric H.pylori positive and negative groups (p > 0.05). Comparing to those with negative for both genes, in children whose dental biofilm and saliva samples were positive for both 16S rRNA and 23S rRNA genes, significantly higher results for halitosis, and DMFS numbers and significantly lower results for dmfs numbers and pH values were found (p < 0.01). Helicobacter pylori can occur in the oral cavity aside and independently from the stomach. However, the high number of bacteria in the oral cavities of children with gastric H.pylori, an association between the presence of H.pylori and halitosis, DMFS, and pH were found.
Armet is an effector protein mediating aphid-plant interactions.
Wang, Wei; Dai, Huaien; Zhang, Yi; Chandrasekar, Raman; Luo, Lan; Hiromasa, Yasuaki; Sheng, Changzhong; Peng, Gongxin; Chen, Shaoliang; Tomich, John M; Reese, John; Edwards, Owain; Kang, Le; Reeck, Gerald; Cui, Feng
2015-05-01
Aphid saliva is predicted to contain proteins that modulate plant defenses and facilitate feeding. Armet is a well-characterized bifunctional protein in mammalian systems. Here we report a new role of Armet, namely as an effector protein in the pea aphid, Acyrthosiphon pisum. Pea aphid Armet's physical and chemical properties and its intracellular role are comparable to those reported for mammalian Armets. Uniquely, we detected Armet in aphid watery saliva and in the phloem sap of fava beans fed on by aphids. Armet's transcript level is several times higher in the salivary gland when aphids feed on bean plants than when they feed on an artificial diet. Knockdown of the Armet transcript by RNA interference disturbs aphid feeding behavior on fava beans measured by the electrical penetration graph technique and leads to a shortened life span. Inoculation of pea aphid Armet protein into tobacco leaves induced a transcriptional response that included pathogen-responsive genes. The data suggest that Armet is an effector protein mediating aphid-plant interactions. © FASEB.
Effect of temperature on the orthodontic clinical applications of niti closed-coil springs
Espinar-Escalona, Eduardo; Llamas-Carreras, José M.; Barrera-Mora, José M.; Abalos-Lasbrucci, Camilo
2013-01-01
NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the austenitic retransformation during the unloading. The temperature variations induced changes in the spring force. Objectives: The aim of this study is to investigate the effect of the temperature variations in the spring forces and corrosion behaviour simulating the ingestion hot/cold drinks and food. Study Design: The springs were subjected to a tensile force using universal testing machine MTS-Adamel (100 N load cell). All tests were performed in artificial saliva maintained at different temperatures. The corrosion tests were performed according to the ISO-standard 10993-15:2000. Results: The increase in temperature of 18oC induced an increase in the spring force of 30%. However, when the temperature returns to 37oC the distraction force recovers near the initial level. After cooling down the spring to 15oC, the force decreased by 46%. This investigation show as the temperature increase, the corrosion potential shifts towards negative values and the corrosion density is rising. Conclusions: The changes of the temperatures do not modify the superelastic behaviour of the NiTi closed-coil springs. The corrosion potential of NiTi in artificial saliva is decreasing by the rise of the temperatures. Key words:Superelasticity, NiTi, springs, orthodontic, coils, recovery, temperature. PMID:23722142
In vitro study of color stability of polycrystalline and monocrystalline ceramic brackets
de Oliveira, Cibele Braga; Maia, Luiz Guilherme Martins; Santos-Pinto, Ary; Gandini Júnior, Luiz Gonzaga
2014-01-01
Objective The aim of this in vitro study was to analyze color stability of monocrystalline and polycrystalline ceramic brackets after immersion in dye solutions. Methods Seven ceramic brackets of four commercial brands were tested: Two monocrystalline and two polycrystalline. The brackets were immersed in four dye solutions (coffee, red wine, Coke and black tea) and in artificial saliva for the following times: 24 hours, 7, 14 and 21 days, respectively. Color changes were measured by a spectrophotometer. Data were assessed by Multivariate Profile Analysis, Analysis of Variance (ANOVA) and Multiple Comparison Tests of means. Results There was a perceptible change of color in all ceramic brackets immersed in coffee (ΔE* Allure = 7.61, Inspire Ice = 6.09, Radiance = 6.69, Transcend = 7.44), black tea (ΔE* Allure = 6.24, Inspire Ice = 5.21, Radiance = 6.51, Transcend = 6.14) and red wine (ΔE* Allure = 6.49, Inspire Ice = 4.76, Radiance = 5.19, Transcend = 5.64), but no change was noticed in Coke and artificial saliva (ΔE < 3.7). Conclusion Ceramic brackets undergo color change when exposed to solutions of coffee, black tea and red wine. However, the same crystalline structure, either monocrystalline or polycrystalline, do not follow the same or a similar pattern in color change, varying according to the bracket fabrication, which shows a lack of standardization in the manufacturing process. Coffee dye produced the most marked color changes after 21 days of immersion for most ceramic brackets evaluated. PMID:25279530
Heggendorn, Fabiano Luiz; Gonçalves, Lucio Souza; Dias, Eliane Pedra; de Oliveira Freitas Lione, Viviane; Lutterbach, Márcia Teresa Soares
2015-08-01
This study assessed the biocorrosive capacity of two bacteria: Desulfovibrio desulfuricans and Desulfovibrio fairfieldensis on endodontic files, as a preliminary step in the development of a biopharmaceutical, to facilitate the removal of endodontic file fragments from root canals. In the first stage, the corrosive potential of the artificial saliva medium (ASM), modified Postgate E medium (MPEM), 2.5 % sodium hypochlorite (NaOCl) solution and white medium (WM), without the inoculation of bacteria was assessed by immersion assays. In the second stage, test samples were inoculated with the two species of sulphur-reducing bacteria (SRB) on ASM and modified artificial saliva medium (MASM). In the third stage, test samples were inoculated with the same species on MPEM, ASM and MASM. All test samples were viewed under an infinite focus Alicona microscope. No test sample became corroded when immersed only in media, without bacteria. With the exception of one test sample between those inoculated with bacteria in ASM and MASM, there was no evidence of corrosion. Fifty percent of the test samples demonstrated a greater intensity of biocorrosion when compared with the initial assays. Desulfovibrio desulfuricans and D. fairfieldensis are capable of promoting biocorrosion of the steel constituent of endodontic files. This study describes the initial development of a biopharmaceutical to facilitate the removal of endodontic file fragments from root canals, which can be successfully implicated in endodontic therapy in order to avoiding parendodontic surgery or even tooth loss in such events.
The effect of different drinks on tooth color after home bleaching
Karadas, Muhammet; Seven, Nilgun
2014-01-01
Objective: This study evaluated the influence of coffee, tea, cola, and red wine staining on the color of teeth after home bleaching. Materials and Methods: A total of 45 samples were obtained from 45 sound maxillary central incisors. The home bleaching procedure was performed using 10% carbamide peroxide gel applied to the sample surface for a period of 6 h each day, for 14 days. After bleaching, baseline color measurements were taken, and the samples were immersed in four staining solutions (coffee, tea, cola, and red wine) or artificial saliva (n = 9). Following 15 min and 6 h of immersion on the first day and next day, respectively, the samples were washed with distilled water for 10 s. After 15 min, 6 h, 1 week, and 1 month immersions, the color values of each sample were remeasured and the color change values (∆E) were calculated. Color change analysis was performed using a spectrophotometer. The results were analyzed using analysis of variance and Tukey's honestly significant difference test (P <0.05). Results: Of all the staining solutions, the lowest ∆E values were observed with coffee staining versus artificial saliva (control group), for all time intervals evaluated after whitening. Although no statistically differences were observed between the coffee and control group at all the time points evaluated, there were statistically significant differences between the red wine, cola, and tea solutions. Conclusion: Following tooth whitening, patients should avoid drinks that cause tooth staining, particularly red wine, tea and cola. PMID:24966778
In vitro study of color stability of polycrystalline and monocrystalline ceramic brackets.
de Oliveira, Cibele Braga; Maia, Luiz Guilherme Martins; Santos-Pinto, Ary; Gandini Junior, Luiz Gonzaga
2014-01-01
The aim of this in vitro study was to analyze color stability of monocrystalline and polycrystalline ceramic brackets after immersion in dye solutions. Seven ceramic brackets of four commercial brands were tested: Two monocrystalline and two polycrystalline. The brackets were immersed in four dye solutions (coffee, red wine, Coke and black tea) and in artificial saliva for the following times: 24 hours, 7, 14 and 21 days, respectively. Color changes were measured by a spectrophotometer. Data were assessed by Multivariate Profile Analysis, Analysis of Variance (ANOVA) and Multiple Comparison Tests of means. There was a perceptible change of color in all ceramic brackets immersed in coffee (ΔE* Allure = 7.61, Inspire Ice = 6.09, Radiance = 6.69, Transcend = 7.44), black tea (ΔE* Allure = 6.24, Inspire Ice = 5.21, Radiance = 6.51, Transcend = 6.14) and red wine (ΔE* Allure = 6.49, Inspire Ice = 4.76, Radiance = 5.19, Transcend = 5.64), but no change was noticed in Coke and artificial saliva (ΔE < 3.7). Ceramic brackets undergo color change when exposed to solutions of coffee, black tea and red wine. However, the same crystalline structure, either monocrystalline or polycrystalline, do not follow the same or a similar pattern in color change, varying according to the bracket fabrication, which shows a lack of standardization in the manufacturing process. Coffee dye produced the most marked color changes after 21 days of immersion for most ceramic brackets evaluated.
Ayaz, Elif Aydoğan; Bağış, Bora; Turgut, Sedanur
2015-10-16
The purpose of this study was to evaluate the effects of thermal cycling on the surface roughness, hardness and flexural strength of denture resins. Polyamide (PA; Deflex and Valplast) and polymethylmethacrylate (PMMA; QC-20 and Acron MC) denture materials were selected. A total of 180 specimens were fabricated and then divided into 3 groups. The first group (group 1) acted as a control and was not thermocycled. The second group (group 2) was subjected to thermocycling for 10,000 cycles in artificial saliva and 5,000 cycles in distilled water. The last group (group 3) was thermocycled for 20,000 cycles in artificial saliva and 10,000 cycles in distilled water. The surface roughness were measured with a profilometer. The hardness of the resins were measured with a Vickers Hardness Tester using a 100-gf load. The flexural strength test was performed using the universal test machine with a crosshead speed of 5 mm/min. Data were analyzed using statistical software. The results of the measurements in the 3 different tests were analyzed by Kruskal-Wallis test with Bonferroni correction. Multiple comparisons were made by Conover and Wilcoxon tests. There was a significant difference between the PMMA and PA groups in terms of surface roughness, hardness and transverse strength before and after thermal cycling (p<0.001). Thermal cycling did not change the surface roughness, hardness and flexural strength values of either the PMMA or PA group (p>0.001).
Backus, Elaine A; Shugart, Holly J; Rogers, Elizabeth E; Morgan, J Kent; Shatters, Robert
2015-05-01
Xylella fastidiosa is unique among insect-transmitted plant pathogens because it is propagative but noncirculative, adhering to and multiplying on the cuticular lining of the anterior foregut. Any inoculation mechanism for X. fastidiosa must explain how bacterial cells exit the vector's stylets via the food canal and directly enter the plant. A combined egestion-salivation mechanism has been proposed to explain these unique features. Egestion is the putative outward flow of fluid from the foregut via hypothesized bidirectional pumping of the cibarium. The present study traced green fluorescent protein-expressing X. fastidiosa or fluorescent nanoparticles acquired from artificial diets by glassy-winged sharpshooters, Homalodisca vitripennis, as they were egested into simultaneously secreted saliva. X. fastidiosa or nanoparticles were shown to mix with gelling saliva to form fluorescent deposits and salivary sheaths on artificial diets, providing the first direct, conclusive evidence of egestion by any hemipteran insect. Therefore, the present results strongly support an egestion-salivation mechanism of X. fastidiosa inoculation. Results also support that a column of fluid is transiently held in the foregut without being swallowed. Evidence also supports (but does not definitively prove) that bacteria were suspended in the column of fluid during the vector's transit from diet to diet, and were egested with the held fluid. Thus, we hypothesize that sharpshooters could be true "flying syringes," especially when inoculation occurs very soon after uptake of bacteria, suggesting the new paradigm of a nonpersistent X. fastidiosa transmission mechanism.
Technical Note: Artificial coral reef mesocosms for ocean acidification investigations
NASA Astrophysics Data System (ADS)
Leblud, J.; Moulin, L.; Batigny, A.; Dubois, P.; Grosjean, P.
2014-11-01
The design and evaluation of replicated artificial mesocosms are presented in the context of a thirteen month experiment on the effects of ocean acidification on tropical coral reefs. They are defined here as (semi)-closed (i.e. with or without water change from the reef) mesocosms in the laboratory with a more realistic physico-chemical environment than microcosms. Important physico-chemical parameters (i.e. pH, pO2, pCO2, total alkalinity, temperature, salinity, total alkaline earth metals and nutrients availability) were successfully monitored and controlled. Daily variations of irradiance and pH were applied to approach field conditions. Results highlighted that it was possible to maintain realistic physico-chemical parameters, including daily changes, into artificial mesocosms. On the other hand, the two identical artificial mesocosms evolved differently in terms of global community oxygen budgets although the initial biological communities and physico-chemical parameters were comparable. Artificial reef mesocosms seem to leave enough degrees of freedom to the enclosed community of living organisms to organize and change along possibly diverging pathways.
Karlinsey, Robert L; Mackey, Allen C; Stookey, George K; Pfarrer, Aaron M
2009-06-01
To determine the fluoride dose response of experimental NaF dentifrices containing a prospective calcium phosphate technology, along with the corresponding relative enamel and dentin abrasion values. 3 mm diameter bovine enamel specimens were mounted, ground and polished, and softened in a carbopol-lactic acid solution (pH = 5.0) for 36 hours at 37 degrees C. Specimens were then measured for baseline Vickers microhardness and stratified (N = 18, mean VHN = 33) into eight groups. These groups consisted of a placebo paste, four test dentifrices (A, B, C, D) with three of the four (A, B, C) containing a promising calcium phosphate ingredient, Crest Cavity Protection, MI Paste Plus, and PreviDent Booster 5000. The groups were cycled in a lesion reversal pH cycling model consisting of four 2-minute treatment periods (diluted 1:3 with DI water) and one 4-hour acid challenge (carbopol-lactic acid, pH = 5.0) per day. Between these events, specimens were immersed in artificial saliva (pH = 7.0). After 20 days of cycling, the specimens were microdrilled and analyzed for fluoride content, and also measured for Vickers surface microhardness after 10 and 20 days of cycling and after a 2-hour and 16-hour post-cycle acid challenge (carbopol-lactic acid, pH = 5.0). Separately, relative dentin and enamel abrasion (RDA and REA) were performed using the ADA recommended radiotracer method. A fluoride dose response was observed for the test dentifrices after 10 and 20 days of pH cycling, with test dentifrice C promoting the highest remineralization among the groups while both the MI Paste Plus and PreviDent systems provide the least remineralization (one-way ANOVA, SNK, P < 0.05). With respect to enamel fluoride uptake, the group facilitating the highest incorporation of fluoride into the enamel lesion was test dentifrice C, while the least effective NaF system was the MI Paste Plus (one-way ANOVA, SNK, P < 0.05). In terms of formulation abrasion, the REA scores were similar among the test dentifrices, MI Paste Plus, and PreviDent and compared favorably to the ADA reference material score (one-way ANOVA, SNK, P < 0.05); relative to the ADA reference material RDA score, the data indicate that MI Paste Plus was essentially non-abrasive, while PreviDent was significantly more abrasive to dentin (one-way ANOVA, SNK, P < 0.05). Altogether, these data show the developmental test dentifrices demonstrate a fluoride dose response and show great promise in remineralizing white-spot enamel lesions relative to MI Paste Plus and PreviDent.
A Reproducible Oral Microcosm Biofilm Model for Testing Dental Materials
Rudney, J.D.; Chen, R.; Lenton, P.; Li, J.; Li, Y.; Jones, R.S.; Reilly, C.; Fok, A.S.; Aparicio, C.
2012-01-01
Aims Most studies of biofilm effects on dental materials use single-species biofilms, or consortia. Microcosm biofilms grown directly from saliva or plaque are much more diverse, but difficult to characterize. We used the Human Oral Microbial Identification Microarray (HOMIM) to validate a reproducible oral microcosm model. Methods and Results Saliva and dental plaque were collected from adults and children. Hydroxyapatite and dental composite disks were inoculated with either saliva or plaque, and microcosm biofilms were grown in a CDC biofilm reactor. In later experiments, the reactor was pulsed with sucrose. DNA from inoculums and microcosms were analyzed by HOMIM for 272 species. Microcosms included about 60% of species from the original inoculum. Biofilms grown on hydroxyapatite and composites were extremely similar. Sucrose-pulsing decreased diversity and pH, but increased the abundance of Streptococcus and Veilonella. Biofilms from the same donor, grown at different times, clustered together. Conclusions This model produced reproducible microcosm biofilms that were representative of the oral microbiota. Sucrose induced changes associated with dental caries. Significance and Impact of the Study This is the first use of HOMIM to validate an oral microcosm model that can be used to study the effects of complex biofilms on dental materials. PMID:22925110
Guo, Lin; Wang, Yu; Zheng, Yiliang; Huang, Zhipeng; Cheng, Yiyuan; Ye, Jiannong; Chu, Qingcui; Huang, Dongping
2016-03-01
A capillary electrophoresis approach with capacitively coupled contactless conductivity detection method has been developed for the determination of inorganic metabolites (thiocyanate, nitrite and nitrate) in human saliva. Field amplified sample injection, as a simple sample stacking technique, was used in conjunction for online preconcentration of above inorganic anions. A selective separation for the target anions from other coexisting constituents present in saliva could be obtained within 14min in a 10mmol/L His-90mmol/L HAc buffer (pH 3.70) at the separation voltage of -18kV. The limits of detection and limits of quantification of the three analytes were within the range of 3.1-4.9ng/mL (S/N=3) and 10-16ng/mL (S/N=10), respectively. The average recovery data were in the range of 81-108% at three different concentrations. This method provides a simple, rapid and direct approach for metabolite analyses of nitric oxide and cyanide based on noninvasive saliva sample, which presents a potential fast screening tool for clinical test. Copyright © 2016 Elsevier B.V. All rights reserved.
Could Alkali Production Be Considered an Approach for Caries Control?
Gordan, V.V.; Garvan, C.W.; Ottenga, M.E.; Schulte, R.; Harris, P.A.; McEdward, D.; Magnusson, I.
2011-01-01
This study investigated the relationship of arginine deiminase (ADS) and urease activities with dental caries through a case-control study. ADS and urease activities were measured in dental smooth-surface supragingival plaque and whole saliva samples from 93 subjects, who were in three different groups: caries-free (n = 31), caries-active (n = 30), and caries-experienced (n = 32). ADS activity was measured by quantification of the ammonia generated from the incubation of plaque and saliva samples in a mixture containing 50 mM arginine-HCl and 50 mM Tris-maleate buffer, pH 6.0. ADS-specific activity was defined as nanomoles of ammonia generated per minute per milligram of protein. Urease activity was determined by quantification of ammonia produced from 50 mM urea. For bacterial identification and enumeration real-time qPCR analysis was used. Groups were compared using Kruskal-Wallis tests. Spearman correlations were used to analyze plaque metabolic activity and bacterial relationships. The results revealed significantly higher ammonia production from arginine in saliva (1.06 vs. 0.18; p < 0.0001) and plaque samples (1.74 vs. 0.58; p < 0.0001) from caries-free subjects compared to caries-active subjects. Urease levels were about 3-fold higher in the plaque of caries-free subjects (p < 0.0001). Although higher urease activity in saliva of caries-experienced and caries-free subjects was evident, no significant difference was found between the groups. PMID:21071940
Aguirrebeitia, Josu; Abasolo, Mikel; Müftü, Sinan; Vallejo, Javier
2017-04-01
A previous study investigated the effects of the preload and taper-angle mismatch in tapered implant systems on the removal force characteristics of the self-locking mechanism. The present study builds upon the previous one and introduces the effects of the time elapsed between insertion and removal and the presence of saliva in the implant-abutment interface as 2 new additional parameters. The purpose of this in vitro study was to elucidate the influences of design and clinical parameters on the removal force for implant systems that use tapered interference fit (TIF) type connections by measuring the force needed to remove an abutment from an implant. Ninety-six implants with tapered abutment-implant interfaces specifically built for an unreplicated factorial design were tested on a custom-built workbench for removal force. Four levels were chosen for the preload, F P , and the taper mismatch Δθ; 3 levels for the wait time t; and 2 levels for the saliva presence s at the interface. A regression model was used based on physical reasoning and a theoretical understanding of the interface. A 4-way ANOVA was used to evaluate the influence of the main effects and interactions (α=.05). The experiments strongly indicated that preload, taper mismatch, and saliva presence are relevant variables in removal force. The wait time becomes important when its effect is evaluated along with the preload. The results of this study can be used for decision making in the design and use of TIF type systems. The study supports the use of artificial saliva in any implant design experiment because of its significance in the removal force of the abutment. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Role of plaque in the clearance of salivary sucrose and its influence on salivary ph.
Kumar, A; Hedge, R; Dixit, U
2011-01-01
The prevalence of dental caries in children, in India, is higher than many of the industrialized countries. The sugar most commonly associated with dental caries is sucrose, as the microorganisms in the dental plaque have the ability to convert this dietary constituent into various organic acids. This study was conducted to study the effect of the presence of plaque on the salivary clearance of sucrose and to study the effect of the presence of plaque on salivary pH, following sucrose clearance. Salivary sucrose determination was done by using the anthrone technique. A Digital MHOS pH meter estimated the salivary pH. Presence of plaque increased the salivary sucrose clearance time and decreased the salivary pH at various time intervals. The microbial etiology of dental caries is the dynamic relationship among the dental plaque microbiota, dietary carbohydrates, saliva and pH lowering, and the cariogenic potential of the dental plaque. Caries occur preferentially in the dentition sites characterized by high exposure to carbohydrate and diminished salivary effect.
Beuchat, L. R.
1973-01-01
Thermal resistance and minimal pH and temperature conditions for growth of Vibrio parahaemolyticus in artificial media containing 3 and 7% sodium chloride were studied. Growth was observed at pH 4.8 and at 5 C. PMID:4715562
A study of the interactions between glass-ionomer cement and S. sanguis biofilms
NASA Astrophysics Data System (ADS)
Hengtrakool, Chanotai
Glass-ionomer cements (GIC) have been used for dental procedures for many years and more recently in other medical applications such as bone cements, for bone reconstruction and also as drug release agents. The postulated caries-preventive activities of GIC are thought to result from their sealing ability, remineralization potential and antibacterial effects. Extensive 'in vitro' investigations have attempted to quantify these effects. In this study, an artificial mouth model, simulating 'in vivo' conditions at the tooth surface, was used to achieve a better understanding of the interaction of oral bacteria with the cements. This study investigated the interaction of Streptococcus sanguis, a common mouth commensal, with two glass-ionomer formulations (one containing fluoride and the other without fluoride ion) with particular reference to bacterial growth, changes in surface roughness and hardness of the glass-ionomer cement with respect to time. Restorative materials with rough surfaces will promote bacterial accumulation 'in vivo' and plaque formation is one factor in surface degradation. The constant depth film fermenter (CDFF) permits the examination of these phenomena and was used to investigate glass-ionomer/S. sanguis biofilm interaction over periods up to 14 days. In conjunction with these studies, surface roughness was measured using a 3-dimension laser profilometer and the surface hardness evaluated using a micro-indenter. Fluoride release from the cement was measured over 84 days. The results showed that autoclaving the CDFF prior to bacterial innoculate did not appear to affect the long-term fluoride release of the GIC. Laser profilometry revealed that the initial roughness and surface area of the GICs was significantly greater than the hydroxyapatite control. S. sanguis viable counts were significantly reduced for both glass-ionomer formulations in the shortterm, the greater reduction being with fluoride-GIC. S. sanguis biofilms produced similar hardness reduction on the surface of GIC:A to those observed with lactic acid pH 5 and artificial saliva whereas the effect on GIC:B was equivalent to that of lactic acid pH between 4 and 5. GICs showed changes in surface roughness after removal the biofilms. This indicates that while S. sanguis biofilm is affected by the GIC, there is also an increase in roughness of the cement indicating some degradation.
Rizvi, Abbas; Zafar, Muhammad S; Al-Wasifi, Yasser; Fareed, Wamiq; Khurshid, Zohaib
2016-01-01
This study is aimed to establish the microtensile bond strength of enamel following exposure to an aerated drink at various time intervals with/without application of remineralization agent. In addition, degree of remineralization and demineralization of tooth enamel has been assessed using polarized light microscopy. Seventy extracted human incisors split into two halves were immersed in aerated beverage (cola drink) for 5 min and stored in saliva until the time of microtensile bond testing. Prepared specimens were divided randomly into two study groups; remineralizing group (n = 70): specimens were treated for remineralization using casein phosphopeptides and amorphous calcium phosphate (CPP-ACP) remineralization agent (Recaldent™; GC Europe) and control group (n = 70): no remineralization treatment; specimens were kept in artificial saliva. All specimens were tested for microtensile bond strength at regular intervals (1 h, 1 days, 2 days, 1 week, and 2 weeks) using a universal testing machine. The results statistically analyzed (P = 0.05) using two-way ANOVA test. Results showed statistically significant increase in bond strength in CPP-ACP tested group (P < 0.05) at all-time intervals. The bond strength of remineralizing group samples at 2 days (~13.64 megapascals [MPa]) is comparable to that of control group after 1 week (~12.44 MPa). CPP-ACP treatment of teeth exposed to an aerated drink provided significant increase in bond strength at a shorter interval compared to teeth exposed to saliva alone.
Tunable alumina 2D photonic-crystal structures via biomineralization of peacock tail feathers
NASA Astrophysics Data System (ADS)
Jiang, Yonggang; Wang, Rui; Feng, Lin; Li, Jian; An, Zhonglie; Zhang, Deyuan
2018-04-01
Peacock tail feathers with subtle periodic nanostructures exhibit diverse striking brilliancy, which can be applied as natural templates to fabricate artificial photonic crystals (PhCs) via a biomineralization method. Alumina photonic-crystal structures are successfully synthesized via an immersion and two-step calcination process. The lattice constants of the artificial PhCs are greatly reduced compared to their natural matrices. The lattice constants are tunable by modifying the final annealing conditions in the biomineralization process. The reflection spectra of the alumina photonic-crystal structures are measured, which is related to their material and structural parameters. This work suggests a facile fabrication process to construct alumina PhCs with a high-temperature resistance.
Sgan-Cohen, H D; Bajali, M; Eskander, L; Steinberg, D; Zini, A
2015-01-01
There are currently inadequate data regarding the prevalence of dental caries and its associated variables, among Palestinian children. To determine the current prevalence of dental caries and related variables, among Palestinian children in East Jerusalem. A stratified sample of 286 East Jerusalem Palestinian children was selected, employing randomly chosen sixth grade clusters from three pre-selected socio-economic school groups. Dental caries was recorded according to WHO recommendations. Salivary flow, pH, buffer capacity and microbial parameters, were recorded according to previously employed methodologies. The mean level of caries experience, by DMFT, was 1.98 ± 2.05. This level was higher than those found among Israeli children, but lower than several other Middle Eastern countries. In uni-variate analysis, significant associations were revealed between caries and school categories, which indicated lower, middle and higher socio-economic position(SEP), mothers' employment, home densities, dental visits, tooth brushing, Streptococci mutans (SM), Lactobacilli (LB), and saliva pH. According to a linear logistic regression model, children learning in lower SEP schools, with higher SM levels and more acidic saliva, had a higher chance of experiencing dental caries. These findings should be considered in the planning of services and dental health care programs for Palestinian children.
Feng, Yong-wen; Wu, Ming; Li, Ying; Zeng, Jing-jing; Li, Ming-li; He, Yun; Li, Dan-hui; Cui, Man-li
2012-02-01
To investigate the direct relationship and significance between the pH value of gastric juice and positive fungi in culture critical patients with artificial airway in intensive care unit (ICU) by analyzing and identifying the type of fungi and their sensitivity to antifungal therapy. A prospective study was conducted.One hundred and sixty patients (between December, 2008 and October, 2011) with artificial airway lasting longer than 48 hours were studied in the ICU at the First Affiliated Hospital of Shenzhen University. The gastric juice specimens were collected through a nasogastric tube, their pH values were measured using precise litmus paper. These samples were divided into six groups according to their pH values: pH ≤ 2.0, pH 2.1-3.0, pH 3.1-4.0, pH 4.1-5.0, pH 5.1-6.0 and pH 6.1-7.0, and then fungi were cultured in these specimens with different pH values. Susceptibility of different fungicide drugs were also investigated. The susceptibility of fungi to gastric juice with different pH values was also investigated. The relationship between 28-day survival rate and the presence of fungi in gastric juice was analyzed in order to analyze the relationship of the presence of fungi in gastric juice and clinical outcome. (1) No fungal growth was found in the gastric juice with pH value lower than 4.0, and the positive rate of fungal culture was significantly increased when the pH value of gastric juice raised. (2) The positive rate of fungal growth was 27.9% (55/197), in which, the positive rate of Candida and non-Candida fungi was 38.2% (21/55) and 61.8% (34/55) respectively, and the difference was significant statistically [χ(2) = 4.16, P < 0.05]. (3) The fungal positive rate was 40.0% (22/55) and 60.0% (33/55) respectively, in survivors (102 cases) and non-survivors (58 cases). The percentage of Candida infection and non-Candida infection was 54.5% (12/22) and 45.5% (10/22) respectively, in survivors, and it was 27.3% (9/33) and 72.7% (24/33), respectively, in non-survivors. The rate of resistance of Candida and non-Candida fungi was 4.7%-14.3% (mean 10.1%) and 0-60% (mean 28.5%) respectively. Positive fungus culture rate was higher in critical patients with artificial airway and higher gastric juice pH values. Non-Candida fungi were mainly found in gastric juice with increasing resistance rate. Candida was more commonly found in survivors, and non-Candida fungi were more commonly found in non-survivors.
Nano-hydroxyapatite could Compensate the Adverse Effect of soft carbonated Drinks on Enamel.
Rezvani, Mohammad B; Rouhollahi, Mohammad R; Andalib, Fahimeh; Hamze, Faeze
2016-08-01
Since one of the most important disadvantages of soft drinks includes their adverse effect on mineral content of enamel because of their low pH, this study examined the microhardness of enamel before and after exposure to a soft drink containing different concentrations of nano-hydroxyapatite (nano-HA) as an additive. Sixty caries free human premolars were mounted in epoxy resin. After polishing, the baseline micro-hardness was recorded three times for each specimen using a Vickers indenter at 50 gm load. Subsequently, the samples were divided into six groups, which were treated for 5 minutes at 9°C by a cola-based drink contacting 0, 0.5, 1, 5, and 10 wt.% of nano-HA while the control group was immersed in artificial saliva. Ultimately, the final microhardness was assessed three times again for each specimen. Paired t-test showed that in groups containing 0 and 0.5 wt.% of nano-HA, the microhardness was significantly reduced after treatment protocol (p = 0.00 and 0.01 respectively). Whereas in the other groups the microhardness was not significantly changed after treatment (p > 0.05). Pure cola-based drink has a pronounced adverse effect on enamel microhardness, while admixing it with nano-HA could act as a protective factor. Although soft beverages are hazardous to tooth structure, some additives could compensate their adverse effect.
Marquezin, Maria Carolina Salomé; Pedroni-Pereira, Aline; Araujo, Darlle Santos; Rosar, João Vicente; Barbosa, Taís S; Castelo, Paula Midori
2016-08-01
The objective of this study is to better understand salivary and masticatory characteristics, this study evaluated the relationship among salivary parameters, bite force (BF), masticatory performance (MP) and gustatory sensitivity in healthy children. The secondary outcome was to evaluate possible gender differences. One hundred and sixteen eutrophic subjects aged 7-11 years old were evaluated, caries-free and with no definite need of orthodontic treatment. Salivary flow rate and pH, total protein (TP), alpha-amylase (AMY), calcium (CA) and phosphate (PHO) concentrations were determined in stimulated (SS) and unstimulated saliva (US). BF and MP were evaluated using digital gnathodynamometer and fractional sieving method, respectively. Gustatory sensitivity was determined by detecting the four primary tastes (sweet, salty, sour and bitter) in three different concentrations. Data were evaluated using descriptive statistics, Mann-Whitney/t-test, Spearman correlation and multiple regression analysis, considering α = 0.05. Significant positive correlation between taste and age was observed. CA and PHO concentrations correlated negatively with salivary flow and pH; sweet taste scores correlated with AMY concentrations and bitter taste sensitivity correlated with US flow rate (p < 0.05). No significant difference between genders in salivary, masticatory characteristics and gustatory sensitivity was observed. The regression analysis showed a weak relationship between the distribution of chewed particles among the different sieves and BF. The concentration of some analytes was influenced by salivary flow and pH. Age, saliva flow and AMY concentrations influenced gustatory sensitivity. In addition, salivary, masticatory and taste characteristics did not differ between genders, and only a weak relation between MP and BF was observed.
Rinaldi, Alessandra; Gambuti, Angelita; Moio, Luigi
2012-04-01
Astringency is a complex sensation mainly caused by the precipitation of salivary proteins with polyphenols. In wine it can be enhanced or reduced depending on the composition of the medium. In order to investigate the effect of ethanol, tartaric acid, fructose, and commercial mannoproteins (MPs) addition on the precipitation of salivary proteins, the saliva precipitation index (SPI) was determined by means of the sodium dodecyl sulphate polyacrylamide gel electrophoresis of human saliva after the reaction with Merlot wines and model solutions. Gelatin index, ethanol index, and Folin-Ciocalteu index were also determined. As resulted by Pearson's correlation, data on SPI were well correlated with the sensory analysis performed on the same samples. In a second experiment, increasing the ethanol (11%-13%-17%), MPs (0-2-8 g/L), fructose (0-2-6 g/L) level, and pH values (2.9-3.0-3.6), a decrease in the precipitation of salivary proteins was observed. A difference in the SPI between model solution and red wine stated that an influence of wine matrix on the precipitation of salivary proteins occurred. Results provide interesting suggestions for enologists, which could modulate the astringency of red wine by: (i) leaving some residual reducing sugars (such as fructose) in red wine during winemaking of grapes rich in tannins; (ii) avoiding the lowering of pH; (iii) adding commercial mannoproteins or promoting a "sur lie" aging; and (iv) harvesting grapes at high technological maturity in order to obtain wines with a satisfactory alcoholic content when possible. © 2012 Institute of Food Technologists®
Kobus, Agnieszka; Kierklo, Anna; Zalewska, Anna; Kuźmiuk, Anna; Szajda, Sławomir Dariusz; Ławicki, Sławomir; Bagińska, Joanna
2017-06-02
There have been inconsistent conclusions regarding salivary abnormalities and their effect on oral health of Juvenile Idiopathic Arthritis (JIA) patients. The purpose of the study was to evaluate the flow rate and selected biochemical parameters of unstimulated whole saliva in correlation to oral health in JIA children. Thirty-four JIA patients and 34 age- and sex-matched controls not affected by JIA (C) were divided into two groups: with mixed and permanent dentition. DMFT/dmft, gingival and simplified oral hygiene indices were evaluated. Salivary flow rate, pH, lysozyme, lactoferrin, salivary protein concentrations and peroxidase activity were assessed. The salivary flow rate was significantly lower in the total JIA group (0.41 ml/min) as compared with the C (0.51 ml/min) and in the permanent dentition of JIA children (0.43 ml/min) as compared with the C (0.61 ml/min). A significantly lower pH was observed in total (6.74), mixed (6.7) and permanent (6.76) dentition of JIA groups in comparison to the C (7.25, 7.21, 7.28 respectively). The specific activity of peroxidase was significantly higher in JIA patients (total 112.72 IU/l, mixed dentition 112.98 IU/l, permanent dentition 112.5 IU/l) than in the C group (total 70.03 IU/l, mixed dentition 71.83 IU/l, permanent dentition 68.61 IU/l). The lysozyme concentration in JIA patients (total and permanent dentition groups) was significantly higher than in the C group. There were no significant differences in lactoferrin and salivary protein concentrations. There were no statistically significant differences in oral status between JIA patients and C, respectively: DMFT = 5.71, dmft = 3.73, OHI-S = 0.95, GI = 0.25 and DMFT 5.71, dmft = 3.73, OHI-S = 0.85, GI = 0.24. The specific activity of peroxidase in the unstimulated whole saliva was inversely correlated with the GI index, whereas the salivary lysozyme concentration was inversely correlated with the dmft index in JIA patients. In the course of JIA occur a reduction of the resting salivary flow rate and a decrease of saliva pH. In spite of this, no differences in the clinical oral status between the JIA children population and the control group were found. The mobilisation of salivary peroxidase and lysozyme contributes to the maintenance of healthy oral tissues.
Kumar, Shikhar; Sogi, Suma H P; Indushekar, K R
2013-01-01
This research paper primarily focuses on the importance of use of xylitol among school children. The purpose of this paper is to evaluate the salivary and dental plaque pH changes after consumption of sugared and sugar-free (xylitol) chewing gums in children. A total of 30 school children were selected for this study and were divided into two equal groups and given both chewing gums for the experiment. Children consuming the sugar-free (xylitol) chewing gum showed a marked increase in the pH of saliva and plaque when compared to their counterpart. All these values had a significant difference of P ≤ 0.0001. Xylitol is a safe all-natural sweetener which helps to reduce tooth decay. It plays a unique role in preventive strategies for better health.
Bio-corrosion and cytotoxicity studies on novel Zr 55Co 30Ti 15 and Cu 60Zr 20Ti 20 metallic glasses
Vincent, S.; Daiwile, A.; Devi, S. S.; ...
2014-09-26
Metallic glasses are a potential and compatible implant candidate for biomedical applications. In the present investigation, a comparative study between novel Zr 55Co 30Ti 15 and Cu 60Zr 20Ti 20 metallic glasses is carried out to evaluate in vitro biocompatibility using simulated body fluids. The bio-corrosion behavior of Zr- and Cu-based metallic glasses in different types of artificial body fluids such as artificial saliva solution, phosphate-buffered saline solution, artificial blood plasma solution, and Hank’s balanced saline solution is evaluated using potentiodynamic polarization studies at a constant body temperature of 310.15 K (37 °C). Surface morphology of samples after bio-corrosion experimentsmore » was observed by scanning electron microscopy. In vitro cytotoxicity test on glassy alloys were performed using human osteosarcoma cell line as per 10993-5 guidelines from International Organization for Standardization. As a result, the comparative study between Zr- and Cu-based glassy alloys provides vital information about the effect of elemental composition on biocompatibility of metallic glasses.« less
Gambuti, Angelita; Rinaldi, Alessandra; Ugliano, Maurizio; Moio, Luigi
2013-02-27
The aim of this study was to evaluate the effect of oxygen exposure of red wine, before (micro-oxygenation) and after (nano-oxygenation) bottling, on the phenolic composition and astringency of wine. The astringency was evaluated by sensory analysis and by a method based on the SDS-PAGE of salivary proteins after reaction of saliva with wine (SPI, saliva precipitation index). Micro-oxygenation caused a stabilization of color, but this effect disappeared after long aging. For the wine with the lower pH a decrease of wine astringency and SPI was observed 42 months after micro-oxygenation. Oxygen ingress through the closure postbottling was positively correlated with the decrease of SPI. Therefore, the astringency and reactivity of wines toward salivary proteins of a bottled red wine can be modulated by controlled oxygen exposure during aging. For both experiments the effect of oxygen exposure depended on wine composition.
Mori, Masanobu; Yamamoto, Tsukasa; Kaseda, Maki; Yamada, Sachiko; Itabashi, Hideyuki
2012-03-01
A combination of polyvinyl alcohol chemically coated capillary (PVA capillary) and background electrolyte (BGE) with ion-pair reagent (hexamethonium dichloride, HMC) was used on capillary ion electrophoresis-UV detection (CIE-UV) for analysis of Br⁻, I⁻, NO₂⁻, NO₃⁻, SCN⁻ and uric acid in human saliva. The PVA capillary prepared in our laboratory minimized electro-osmotic flow (EOF) at the BGE in pH 3-10, and did not affect the UV detection at 210 nm by the PVA-layer on capillary wall. Therefore, use of the PVA capillary was suitable for sensitive UV detection for analyte anions, as well as suppression of protein adsorption. In this study, we optimized the BGE of 10 mM phosphate plus 10 mM HMC with applying a voltage of -15 kV. HMC as an additive to BGE could manipulate the electrophoretic mobility of anions, without electrostatic adsorption to the PVA capillary. The CIE-UV could separate and determine analyte anions in human saliva containing proteins by the direct injection without pretreatments such as dilution or deproteinization within 13 min. The relative standard deviations (n=10) were ranged of 0.5-1.6% in migration times, 2.2-6.8% in peak heights and 2.8-8.4% in peak areas. The limits of detection (S/N=3) were ranged of 3.42-6.87 μM. The peak height of anions in this system was gradually decreased through the successive injections of saliva samples, but the problem was successfully solved by periodically conditioning the PVA capillary. The quantifiability of anions in human saliva samples by the CIE-UV was evaluated through the recoveries by standard addition methods and comparison of other representative analytical methods, as well as identification by ion chromatography (IC). From the anion analyses in 12 different saliva samples, the CIE-UV demonstrated that can obtain obvious differences in concentrations of SCN⁻ between of smoker and non-smoker and those of uric acid between male and female with satisfactory results. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
de Souza, Cláudio M. D.; Carneiro, Cristine E. A.; Baú, João Paulo T.; da Costa, Antonio C. S.; Ivashita, Flávio F.; Paesano, Andrea; di Mauro, Eduardo; de Santana, Henrique; Holm, Nils G.; Neubeck, Anna; Zaia, Cássia T. B. V.; Zaia, Dimas A. M.
2013-04-01
In the present work, the interactions between forsterite-91 with distilled water and forsterite-91 with artificial seawater were studied at two pHs (2.0 and 8.0) using different techniques. A large increase in pH was observed for samples incubated at an initially acidic pH (2.0) due to the dissolution of forsterite-91 in distilled water and artificial seawater. Thus, in acidic hydrothermal vents, an increase in the amount of hydrocarbons and magnetite should be expected due to the release of Fe(II). The pHPZC decreased and the pHIEP increased when forsterite-91 was treated with distilled water and artificial seawater. The ions from the artificial seawater had an effect on zeta potential. Scanning electron microscopy (SEM) images and X-ray diffractograms showed halite in the samples of forsterite-91 mixed with artificial seawater. The presence of halite or adsorption of ions on the surface of forsterite-91 could affect the synthesis of magnetite and hydrocarbons in hydrothermal vents, due to a decrease in the dissolution rates of forsterite-91. The dissolution of forsterite-91 yields low concentrations of Fe(III) and Mn(II) as detected by electron paramagnetic resonance (EPR) spectroscopy. Microanalysis of forsterite-91 showed a higher amount of Mn, with an oxidation that was likely not +II, as Mn in supernatant solutions was only detected by EPR spectroscopy after mixing with artificial seawater at pH 2.0. As Fe(III) and Mn(II) are catalyst constituents of magnetite and manganese oxide, respectively, their presence is important for synthesis in hydrothermal vents. Etch pits were observed only in the forsterite-91 sample mixed with distilled water at pH 8.0. Na, Cl, S, Ca and K were detected in the samples mixed with artificial seawater by SEM-EDS. Si, Mg, Fe and Al were detected in almost all supernatant samples due to forsterite-91 dissolution. Cr was not dissolved in the experiments, thus Cr in the mineral could serve as an effective catalyst for Fischer Tropsch Types (FTT) reactions in hydrothermal vent systems. X-ray diffractograms of the original forsterite-91 also showed peaks arising from zeolites and clinochlore. After the samples were treated with artificial seawater, X-ray diffractograms showed the dissolution of zeolite. Experiments should be performed in the natural environment to verify the potential for zeolites to act as a catalyst in hydrothermal vents.
2016-06-01
plaque or exogenous acid sources (e.g. sugar and soda) outweigh the protective factors of saliva (calcium, phosphate, antibacterial factors, and...ecological catastrophes? Microbiology, 149(Pt 2), 279-294. Martignon S, Ekstrand KR, Ellwood R. (2006). Efficacy of sealing proximal early active ...oral hydrogen-ion concentrations associated with dental caries activity . Journal of Dental Research, 23(4), 257-266. Stephan RM. (1947). pH and
Functional Evaluation of Proteins in Watery and Gel Saliva of Aphids
van Bel, Aart J. E.; Will, Torsten
2016-01-01
Gel and watery saliva are regarded as key players in aphid–pIant interactions. The salivary composition seems to be influenced by the variable environment encountered by the stylet tip. Milieu sensing has been postulated to provide information needed for proper stylet navigation and for the required switches between gel and watery saliva secretion during stylet progress. Both the chemical and physical factors involved in sensing of the stylet’s environment are discussed. To investigate the salivary proteome, proteins were collected from dissected gland extracts or artificial diets in a range of studies. We discuss the advantages and disadvantages of either collection method. Several proteins were identified by functional assays or by use of proteomic tools, while most of their functions still remain unknown. These studies disclosed the presence of at least two proteins carrying numerous sulfhydryl groups that may act as the structural backbone of the salivary sheath. Furthermore, cell-wall degrading proteins such a pectinases, pectin methylesterases, polygalacturonases, and cellulases as well as diverse Ca2+-binding proteins (e.g., regucalcin, ARMET proteins) were detected. Suppression of the plant defense may be a common goal of salivary proteins. Salivary proteases are likely involved in the breakdown of sieve-element proteins to invalidate plant defense or to increase the availability of organic N compounds. Salivary polyphenoloxidases, peroxidases and oxidoreductases were suggested to detoxify, e.g., plant phenols. During the last years, an increasing number of salivary proteins have been categorized under the term ‘effector’. Effectors may act in the suppression (C002 or MIF cytokine) or the induction (e.g., Mp10 or Mp 42) of plant defense, respectively. A remarkable component of watery saliva seems the protein GroEL that originates from Buchnera aphidicola, the obligate symbiont of aphids and probably reflects an excretory product that induces plant defense responses. Furthermore, chitin fragments in the saliva may trigger defense reactions (e.g., callose deposition). The functions of identified proteins and protein classes are discussed with regard to physical and chemical characteristics of apoplasmic and symplasmic plant compartments. PMID:28018380
Ash, A; Wilde, P J; Bradshaw, D J; King, S P; Pratten, J R
2016-03-14
The salivary conditioning film (SCF) that forms on all surfaces in the mouth plays a key role in lubricating the oral cavity. As this film acts as an interface between tongue, enamel and oral mucosa, it is likely that any perturbations to its structure could potentially lead to a change in mouthfeel perception. This is often experienced after exposure to oral hygiene products. For example, consumers that use dentifrice that contain a high concentration of sodium bicarbonate (SB) often report a clean mouth feel after use; an attribute that is clearly desirable for oral hygiene products. However, the mechanisms by which SB interacts with the SCF to alter lubrication in the mouth is unknown. Therefore, saliva and the SCF was exposed to high ionic strength and alkaline solutions to elucidate whether the interactions observed were a direct result of SB, its high alkalinity or its ionic strength. Characteristics including bulk viscosity of saliva and the viscoelasticity of the interfacial salivary films that form at both the air/saliva and hydroxyapatite/saliva interfaces were tested. It was hypothesised that SB interacts with the SCF in two ways. Firstly, the ionic strength of SB shields electrostatic charges of salivary proteins, thus preventing protein crosslinking within the film and secondly; the alkaline pH (≈8.3) of SB reduces the gel-like structure of mucins present in the pellicle by disrupting disulphide bridging of the mucins via the ionization of their cysteine's thiol group, which has an isoelectric point of ≈8.3.
Kondo, Yusuke; Nakamoto, Tetsuji; Mukaibo, Taro; Kidokoro, Manami; Masaki, Chihiro; Hosokawa, Ryuji
2011-04-01
Cevimeline and pilocarpine are muscarinic agonists used clinically to treat dry mouth. In this study, we explored fluid secretion from mouse submandibular glands to determine the mechanism of cevimeline, pilocarpine, and an experimentally used agent carbachol. Cevimeline evoked almost the same amount of secretion at concentrations from 30 μM to 1 mM. Pilocarpine also induced secretion at a concentration as low as 1 μM and was the most powerful secretagogue at 10 μM. Secretion was induced by carbachol at 0.1 μM, with maximum secretion at 1.0 μM. Cevimeline induced monophasic secretion at all concentrations tested, whereas higher concentrations of pilocarpine and carbachol induced secretion with variable kinetics, i.e., an initial transient high flow rate, followed by decreased secretion after 2 to 3 min. In the presence of an epithelial Na(+) channel blocker, amiloride, neither carbachol nor pilocarpine affected the Na(+) level of secreted saliva; however, it significantly increased the Na(+) content of cevimeline-induced saliva. The intracellular Ca(2+) response of acinar cells was almost identical among all three agents, although recovery after drug removal was slower for cevimeline and pilocarpine. A profound decrease in intracellular pH was observed during pilocarpine and carbachol treatment, whereas intracellular acidification induced by cevimeline was only seen in the presence of a Na(+)/H(+) exchange inhibitor. When external HCO(3)(-) was removed, cevimeline-induced saliva significantly decreased. These findings suggest that cevimeline specifically activates Na(+)/H(+) exchange and may promote Na(+) reabsorption by stabilizing epithelial sodium channel activity.
Canhisares-Filho, José E; Carneiro, Cristine E A; de Santana, Henrique; Urbano, Alexandre; da Costa, Antonio C S; Zaia, Cássia T B V; Zaia, Dimas A M
2015-09-01
Minerals could have played an important role in concentration, protection, and polymerization of biomolecules. Although iron is the fourth most abundant element in Earth's crust, there are few works in the literature that describe the use of iron oxide-hydroxide in prebiotic chemistry experiments. In the present work, the interaction of adenine, thymine, and uracil with ferrihydrite was studied under conditions that resemble those of prebiotic Earth. At acidic pH, anions in artificial seawater decreased the pH at the point of zero charge (pHpzc) of ferrihydrite; and at basic pH, cations increased the pHpzc. The adsorption of nucleic acid bases onto ferrihydrite followed the order adenine > uracil > thymine. Adenine adsorption peaked at neutral pH; however, for thymine and uracil, adsorption increased with increasing pH. Electrostatic interactions did not appear to play an important role on the adsorption of nucleic acid bases onto ferrihydrite. Adenine adsorption onto ferrihydrite was higher in distilled water compared to artificial seawater. After ferrihydrite was mixed with artificial seawaters or nucleic acid bases, X-ray diffractograms and Fourier transform infrared spectra did not show any change. Surface-enhanced Raman spectroscopy showed that the interaction of adenine with ferrihydrite was not pH-dependent. In contrast, the interactions of thymine and uracil with ferrihydrite were pH-dependent such that, at basic pH, thymine and uracil lay flat on the surface of ferrihydrite, and at acidic pH, thymine and uracil were perpendicular to the surface. Ferrihydrite adsorbed much more adenine than thymine; thus adenine would have been better protected against degradation by hydrolysis or UV radiation on prebiotic Earth.
Effect of Energy Drinks on Discoloration of Silorane and Dimethacrylate-Based Composite Resins.
Ahmadizenouz, Ghazaleh; Esmaeili, Behnaz; Ahangari, Zohreh; Khafri, Soraya; Rahmani, Aghil
2016-08-01
This study aimed to assess the effects of two energy drinks on color change (ΔE) of two methacrylate-based and a silorane-based composite resin after one week and one month. Thirty cubic samples were fabricated from Filtek P90, Filtek Z250 and Filtek Z350XT composite resins. All the specimens were stored in distilled water at 37°C for 24 hours. Baseline color values (L*a*b*) of each specimen were measured using a spectrophotometer according to the CIEL*a*b* color system. Ten randomly selected specimens from each composite were then immersed in the two energy drinks (Hype, Red Bull) and artificial saliva (control) for one week and one month. Color was re-assessed after each storage period and ΔE values were calculated. The data were analyzed using the Kruskal Wallis and Mann-Whitney U tests. Filtek Z250 composite showed the highest ΔE irrespective of the solutions at both time points. After seven days and one month, the lowest ΔE values were observed in Filtek Z350XT and Filtek P90 composites immersed in artificial saliva, respectively. The ΔE values of Filtek Z250 and Z350XT composites induced by Red Bull and Hype energy drinks were not significantly different. Discoloration of Filtek P90 was higher in Red Bull energy drink at both time points. Prolonged immersion time in all three solutions increased ΔE values of all composites. However, the ΔE values were within the clinically acceptable range (<3.3) at both time points.
Dehghan, Mojdeh; Vieira Ozorio, Jose Estevam; Chanin, Simon; Tantbirojn, Daranee; Versluis, Antheunis; Garcia-Godoy, Franklin
2017-01-01
Tooth erosion from an acidic insult may be exacerbated by toothbrushing. The purposes of this study were to develop an in vitro methodology to measure enamel loss after brushing immediately following an acidic episode and to investigate the effect of brushing with an anti-erosive toothpaste. The null hypotheses tested were that tooth erosion after brushing with the toothpaste would not be different from brushing with water and that a 1-hour delay before brushing would not reduce tooth erosion. Forty bovine enamel slabs were embedded, polished, and subjected to baseline profilometry. Specimens were bathed in hydrochloric acid for 10 minutes to simulate stomach acid exposure before post-acid profilometry. Toothbrushing was then simulated with a cross-brushing machine and followed by postbrushing profilometry. Group 1 was brushed with water; group 2 was brushed with a 50:50 toothpaste-water slurry; and groups 3 and 4 were immersed in artificial saliva for 1 hour before brushing with water or the toothpaste slurry, respectively. The depth of enamel loss was analyzed and compared using 1-way analysis of variance and post hoc testing (α = 0.05). Greater enamel loss was measured in groups brushed with toothpaste than in groups brushed with water. One-hour immersion in artificial saliva significantly reduced enamel loss when teeth were brushed with water (group 3; P < 0.05) but not with toothpaste (group 4). This study established a protocol for measuring enamel loss resulting from erosion followed by toothbrush abrasion. The results confirmed the abrasive action of toothpaste on acid-softened enamel.
Mineral loss and color change of enamel after bleaching and staining solutions combination.
de Araújo, Larissa Sgarbosa Napoleão; dos Santos, Paulo Henrique; Anchieta, Rodolfo Bruniera; Catelan, Anderson; Fraga Briso, André Luiz; Fraga Zaze, Ana Carolina Soares; Sundfeld, Renato Herman
2013-10-01
Pigments of food and beverages could affect dental bleaching efficacy. The aim of this investigation was to evaluate color change and mineral loss of tooth enamel as well as the influence of staining solutions normally used by adolescent patients undergoing home bleaching. Initial hardness and baseline color were measured on enamel blocks. Specimens were divided into five groups (n=5): G1 (control) specimens were kept in artificial saliva throughout the experiment (3 weeks); G2 enamel was exposed to 10% carbamide peroxide for 6 h daily, and after this period, the teeth were cleaned and stored in artificial saliva until the next bleaching session; and G3, G4, and G5 received the same treatments as G2, but after bleaching, they were stored for 1 h in cola soft drink, melted chocolate, or red wine, respectively. Mineral loss was obtained by the percentage of hardness reduction, and color change was determined by the difference between the data obtained before and after treatments. Data were subjected to analysis of variance and Fisher's test (α=0.05). G3 and G5 showed higher mineral loss (92.96 ± 5.50 and 94.46 ± 1.00, respectively) compared to the other groups (p ≤ 0.05). G5 showed high-color change (9.34 ± 2.90), whereas G1 presented lower color change (2.22 ± 0.44) (p ≤ 0.05). Acidic drinks cause mineral loss of the enamel, which could modify the surface and reduce staining resistance after bleaching.
Dentin remineralization in acid challenge environment via PAMAM and calcium phosphate composite.
Liang, Kunneng; Weir, Michael D; Xie, Xianju; Wang, Lin; Reynolds, Mark A; Li, Jiyao; Xu, Hockin H K
2016-11-01
The objective of this study was to investigate the effects of poly (amido amine) (PAMAM), composite with nanoparticles of amorphous calcium phosphate (NACP), and the combined PAMAM+NACP nanocomposite treatment, on remineralization of demineralized dentin in a cyclic artificial saliva/lactic acid environment for the first time. Dentin specimens were prepared and demineralized with 37% phosphoric acid for 15s. Four groups were prepared: (1) dentin control, (2) dentin coated with PAMAM, (3) dentin with NACP composite, (4) dentin with PAMAM+NACP. Specimens were treated with a cyclic artificial saliva/lactic acid regimen for 21days. Acid neutralization and calcium (Ca) and phosphate (P) ion concentrations were measured. The remineralized dentin specimens were examined by scanning electron microscopy (SEM) and hardness testing. NACP nanocomposite had mechanical properties similar to commercial control composites (p>0.1). NACP composite had acid-neutralization and Ca and P ion release capability. PAMAM or NACP composite each alone achieved remineralization and increased the hardness of demineralized dentin (p<0.05). PAMAM+NACP nanocomposite achieved the greatest mineral regeneration in demineralized dentin and the greatest hardness increase in demineralized dentin, which approached the hardness of healthy dentin (p>0.1). The superior remineralization efficacy of PAMAM+NACP was demonstrated for the first time. PAMAM+NACP induced remineralization in demineralized dentin in an acid challenge environment, when conventional remineralization methods such as PAMAM did not work well. The novel PAMAM+NACP composite approach is promising for a wide range of dental applications to inhibit caries and protect tooth structures. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Saffarpour, Mahshid; Mohammadi, Maryam; Tahriri, Mohammadreza; Zakerzadeh, Azadeh
2017-07-01
This study assessed the efficacy of modified bioactive glass (MBG) for dentin remineralization and obstruction of dentinal tubules. Thirty-six dentin discs were made from 20 third molars and were stored in 12% lactic acid solution for two weeks to induce demineralization. The samples were divided into three groups (n=12): 1- BG, 2- BG modified with 5% strontium (Sr) and 3- BG modified with 10% Sr. After applying the BG, the samples were stored in artificial saliva for 7, 14 and 21 days. Attenuated Total Reflection-Fourier Transform Infrared Spectroscopy (ATR-FTIR), X-ray Diffraction (XRD) analysis, Scanning Electron Microscopy (SEM), and Energy-Dispersive X-ray (EDX) analysis were used to assess remineralization. Also, 6 dentin discs were divided into three groups of BG, BG modified with 5% Sr and BG modified with 10% Sr, to examine tubular occlusion. The discs were etched using 0.5M of EDTA for two minutes and were stored in artificial saliva for 7 days. Changes in dentin surface morphology were evaluated under SEM. Group 3 showed high rates of remineralization at days 7 and 14, although the rate decreased at day 21. Group 2 exhibited high rates of remineralization at days 7, 14 and 21. Dentinal tubules were partially occluded by BG and BG modified with 5% Sr, while they were almost completely obstructed after the use of BG modified with 10% Sr. Strontium increases remineralization. Addition of 10% Sr to BG enhances apatite formation; however, the apatite dissolves over time. Addition of 5% Sr to BG stabilizes the apatite lattice and increases the remineralization.
Combining Bioactive Multifunctional Dental Composite with PAMAM for Root Dentin Remineralization
Xiao, Shimeng; Liang, Kunneng; Weir, Michael D.; Cheng, Lei; Liu, Huaibing; Zhou, Xuedong; Ding, Yi; Xu, Hockin H. K.
2017-01-01
Objectives. The objectives of this study were to: (1) develop a bioactive multifunctional composite (BMC) via nanoparticles of amorphous calcium phosphate (NACP), 2-methacryloyloxyethyl phosphorylcholine (MPC), dimethylaminohexadecyl methacrylate (DMAHDM) and nanoparticles of silver (NAg); and (2) investigate the effects of combined BMC + poly (amido amine) (PAMAM) on remineralization of demineralized root dentin in a cyclic artificial saliva/lactic acid environment for the first time. Methods. Root dentin specimens were prepared and demineralized with 37% phosphoric acid for 15 s. Four groups were prepared: (1) root dentin control; (2) root dentin with BMC; (3) root dentin with PAMAM; (4) root dentin with BMC + PAMAM. Specimens were treated with a cyclic artificial saliva/lactic acid regimen for 21 days. Calcium (Ca) and phosphate (P) ion concentrations and acid neutralization were determined. The remineralized root dentin specimens were examined via hardness testing and scanning electron microscopy (SEM). Results. Mechanical properties of BMC were similar to commercial control composites (p = 0.913). BMC had excellent Ca and P ion release and acid-neutralization capability. BMC or PAMAM alone each achieved slight mineral regeneration in demineralized root dentin. The combined BMC + PAMAM induced the greatest root dentin remineralization, and increased the hardness of pre-demineralized root dentin to match that of healthy root dentin (p = 0.521). Significance. The excellent root dentin remineralization effects of BMC + PAMAM were demonstrated for the first time. BMC + PAMAM induced effective and complete root dentin remineralization in an acid challenge environment. The novel BMC + PAMAM method is promising for Class V and other restorations to remineralize and protect tooth structures. PMID:28772450
Combining Bioactive Multifunctional Dental Composite with PAMAM for Root Dentin Remineralization.
Xiao, Shimeng; Liang, Kunneng; Weir, Michael D; Cheng, Lei; Liu, Huaibing; Zhou, Xuedong; Ding, Yi; Xu, Hockin H K
2017-01-22
Objectives . The objectives of this study were to: (1) develop a bioactive multifunctional composite (BMC) via nanoparticles of amorphous calcium phosphate (NACP), 2-methacryloyloxyethyl phosphorylcholine (MPC), dimethylaminohexadecyl methacrylate (DMAHDM) and nanoparticles of silver (NAg); and (2) investigate the effects of combined BMC + poly (amido amine) (PAMAM) on remineralization of demineralized root dentin in a cyclic artificial saliva/lactic acid environment for the first time. Methods . Root dentin specimens were prepared and demineralized with 37% phosphoric acid for 15 s. Four groups were prepared: (1) root dentin control; (2) root dentin with BMC; (3) root dentin with PAMAM; (4) root dentin with BMC + PAMAM. Specimens were treated with a cyclic artificial saliva/lactic acid regimen for 21 days. Calcium (Ca) and phosphate (P) ion concentrations and acid neutralization were determined. The remineralized root dentin specimens were examined via hardness testing and scanning electron microscopy (SEM). Results . Mechanical properties of BMC were similar to commercial control composites ( p = 0.913). BMC had excellent Ca and P ion release and acid-neutralization capability. BMC or PAMAM alone each achieved slight mineral regeneration in demineralized root dentin. The combined BMC + PAMAM induced the greatest root dentin remineralization, and increased the hardness of pre-demineralized root dentin to match that of healthy root dentin ( p = 0.521). Significance . The excellent root dentin remineralization effects of BMC + PAMAM were demonstrated for the first time. BMC + PAMAM induced effective and complete root dentin remineralization in an acid challenge environment. The novel BMC + PAMAM method is promising for Class V and other restorations to remineralize and protect tooth structures.
Use of zinc phosphate cement as a luting agent for Denzir™ copings: an in vitro study
Söderholm, Karl-Johan M; Mondragon, Eduardo; Garcea, Ileana
2003-01-01
Background The clinical success rate with zinc phosphate cemented Procera crowns is high. The objective with this study was to determine whether CADCAM processed and zinc phosphate cemented Denzir copings would perform as well as zinc phosphate cemented Procera copings when tested in vitro in tension. Methods Twelve Procera copings and twenty-four Denzir copings were made. After the copings had been made, twelve of the Denzir copings were sandblasted on their internal surfaces. All copings were then cemented with zinc phosphate cement to carbon steel dies and transferred to water or artificial saliva. Two weeks after cementation, half of the samples were tested. The remaining samples were tested after one year in the storage medium. All tests were done in tension and evaluated with an ANOVA. Results Sandblasted and un-sandblasted Denzir copings performed as well as Procera copings. Storage in water or artificial saliva up to one year did not decrease the force needed to dislodge any of the coping groups. Three copings fractured during testing and one coping developed a crack during testing. The three complete fractures occurred in Procera copings, while the partly cracked coping was a Denzir coping. Conclusion No significant differences existed between the different material groups, and the retentive force increased rather than decreased with time. Fewer fractures occurred in Denzir copings, explained by the higher fracture toughness of the Denzir material. Based on good clinical results with zinc phosphate cemented Procera crowns, we foresee that zinc phosphate cement luted Denzir copings are likely to perform well clinically. PMID:12622874
Salivary buffer effect in relation to late pregnancy and postpartum.
Laine, M; Pienihäkkinen, K
2000-02-01
We studied the salivary pH, buffer effect (BE), and flow rates of unstimulated and paraffin-stimulated saliva of 8 women in their late pregnancy and postpartum. Salivary samples were collected about 1 month prior to and about 2 months after delivery. In non-pregnant control women, two paraffin-stimulated salivary samples were collected 1 month apart. The salivary BE increased significantly from late pregnancy to postpartum without exception. The increase was 2.04 +/- 1.17 pH units (P < 0.001) on average. The BE increased from 4.79 +/- 1.64 (final pH) to 6.82 +/- 1.01 (final pH). This change was not due to variation in salivary flow rates, since both unstimulated and paraffin-stimulated flow rates remained unchanged. In control women the difference between the 2 BE measurements was only 0.13 +/- 0.47 pH units on average. We concluded that women with high postpartum BE values may have moderate or even low BE values in late pregnancy. In control women, individual variation was found to be low in all variables studied.
Meta-Cresol Purple Reference Material® (RM) for Seawater pH Measurements
NASA Astrophysics Data System (ADS)
Easley, R. A.; Waters, J. F.; Place, B. J.; Pratt, K. W.
2016-02-01
The pH of seawater is a fundamental quantity that governs the carbon dioxide - carbonate system in the world's oceans. High quality pH measurements for long-term monitoring, shipboard studies, and shorter-term biological studies (mesocosm and field experiments) can be ensured through a reference material (RM) that is compatible with existing procedures and which is traceable to primary pH measurement metrology. High-precision spectrophotometric measurements of seawater pH using an indicator dye such as meta-cresol purple (mCP) are well established. However, traceability of these measurements to the International System of Units (SI) additionally requires characterizing the spectrophotometric pH response of the dye in multiple artificial seawater buffers that themselves are benchmarked via primary pH (Harned cell) measurements at a range of pH, salinity, and temperature. NIST is currently developing such a mCP pH RM using this approach. This material will also incorporate new procedures developed at NIST for assessing the purity and homogeneity of the mCP reagent itself. The resulting mCP will provide long-term (years) stability and ease of shipment compared to artificial seawater pH buffers. These efforts will provide the oceanographic user community with a NIST issued mCP (RM), characterized as to its molar absorptivity values and acid dissociation constants (pKa), with uncertainties that comply with the Guide to the Expression of Uncertainty in Measurement (GUM).
Electroactive hydrogel comprising poly(methyl 2-acetamido acrylate) for an artificial actuator
NASA Astrophysics Data System (ADS)
Ha, Eun-Ju; Kim, Bong-Soo; Park, Chun-ho; Lee, Jang-Oo; Paik, Hyun-jong
2013-08-01
A poly(methyl 2-acetamidoacrylic acrylate) (MAA) hydrogel was developed for use in an artificial actuator. The equilibrium swelling ratio of the MAA hydrogel was observed at different pH values with different concentrations of cross-linking agent; the hydrogel containing 2% cross-linking agent exhibited the maximum equilibrium swelling ratio at pH 10. The bending behavior of the MAA hydrogel under an electric field was measured in aqueous NaCl. The actuation response of the MAA hydrogel occurred via reversible bending behavior at 6 V. It was found that the MAA hydrogel features stable bending behavior over consecutive cycles in aqueous NaCl at different voltages depending on the cross-linking agent. Hence, the MAA hydrogel can be utilized as an artificial actuator using electrical stimulus.
Kirstilä, V; Lenander-Lumikari, M; Söderling, E; Tenovuo, J
1996-12-01
This study evaluates the effects of two oral hygiene products containing nonimmunoglobulin antimicrobial agents on whole saliva and on subjective oral symptoms in patients with xerostomia. Twenty patients used a lactoperoxidase-system-containing toothpaste (Biotene) combined with the use of a mouthrinse (Biotene), comprising also lysozyme and lactoferrin, for 4 weeks. Saliva samples were collected at base line, after 4 weeks' use of the products, and at the end of a 4-week washout period. Samples were analyzed for selected biochemical and microbiologic factors. The effects on subjective oral symptoms were also recorded. A 4-week daily use of toothpaste and mouthrinse relieved the symptoms of oral dryness in 16 patients. The levels of salivary hypothiocyanite, lysozyme, lactoferrin, or myeloperoxidase activity did not change, but there was a significant decrease in salivary pH (P < 0.05), total peroxidase activity (P < 0.05), and total protein content (P = 0.01). In patients with the lowest salivary flow rates (n = 5) a significant (P > or = 0.04) increase was detected in salivary hypothiocyanite concentrations. No major changes occurred in salivary microflora. The products relieved subjective oral symptoms in most xerostomic patients, but this was not necessarily related to the presence of antimicrobial agents.
A paper strip based non-invasive glucose biosensor for salivary analysis.
Soni, Anuradha; Jha, Sandeep Kumar
2015-05-15
In our present study, we developed an optical biosensor for direct determination of salivary glucose by using immobilized glucose oxidase enzyme on filter paper strip (specific activity 1.4 U/strip) and then reacting it with synthetic glucose samples in presence of co-immobilized color pH indicator. The filter paper changed color based on concentration of glucose in reaction media and hence, by scanning this color change (using RGB profiling) through an office scanner and open source image processing software (GIMP) the concentration of glucose in the reaction medium could be deduced. Once the biosensor was standardized, the synthetic glucose sample was replaced with human saliva from donors. The individual's blood glucose level at the time of obtaining saliva was also measured using an Accuchek(™) active glucometer (Roche Inc.). In this preliminary study, a correlation of nearly 0.64 was found between glucose levels in saliva and blood of healthy individuals and in diabetic patients it was nearly in the order of 0.95, thereby validating the importance of salivary analysis. The RGB profiling method obtained a detection range of 9-1350 mg/dL glucose at a response time of 45 s and LOD of 22.2 mg/dL. Copyright © 2014 Elsevier B.V. All rights reserved.
Vongsavan, Kadkao; Rirattanapong, Praphasri; Surarit, Rudee
2016-03-01
Dental caries are a major public health problem worldwide. The aim of this study was to compare the effects of children's follow-on instant powdered cow's milk formula, buffalo milk formula and a chicken-based formula on microhardness of bovine enamel with artificial caries-like lesions. Forty bovine teeth were each placed in acrylic blocks and the enamel surfaces were polished to create flat 5 x 5 millimeter surfaces. The teeth surfaces were then demineralized using 0.1M lactic acid (pH 4.5) to achieve an enamel microhardness of 35-65 Vickers Hardness Numbers (VHN). All specimens were then randomly allocated into one of 4 groups (n=10/group). For remineralization, each group was soaked in a different kind of milk formula for 2 hours at 37°C except group 1 which was a negative control (artificial saliva) group. Group 2 was soaked in Murrah™ buffalo milk formula (a positive control ), group 3 in S-26-Promil-Gold™ (cow's milk formula) and group 4 in a chicken-based formula (Siriraj Hospital, Mahidol University). The microhardness of the specimens was then measured again. Data were analyzed using a one-way ANOVA and paired t-test with a 95% confidence interval. After exposure to the formula, the mean VHN for each study group was significantly higher (paired t-test, p < 0.05) except for group 1 (p = 0.345). The mean VHN for the the Murrah™ buffalo milk formula, the chicken-based formula and the S-26-Promil-Gold™ formula group were not significantly different from each other (one-way ANOVA, p > 0.05). In conclusion, S-26-Promil-Gold™ follow-on cow milk formula, Murrah™ buffalo milk formula and the chicken-based formula all increased bovine enamel microhardness after soaking for 2 hours.
Schubert, S.; Vente, A.
2017-01-01
ABSTRACT The pharmacodynamics of finafloxacin, ciprofloxacin, and levofloxacin against extended-spectrum-β-lactamase (ESBL)-producing Enterobacteriaceae isolates were compared. Since quinolones lose activity in acidic media, and particularly in urine, their activities were tested in parallel under conventional conditions and in acidic artificial urine. For this purpose, TEM- and SHV-type ESBL-producing Escherichia coli and Klebsiella pneumoniae strains and their wild-type counterparts were exposed in a modified Grasso model to simulated concentrations of drugs in serum and urine following oral doses of either finafloxacin at 800 mg once a day (q.d.), immediate-release ciprofloxacin at 500 mg twice a day (b.i.d.), extended-release ciprofloxacin at 1,000 mg q.d., or levofloxacin at 500 or 750 mg q.d. The concentrations of the drugs in urine were fitted by compartmental modeling. Bacteria were cultivated in Mueller-Hinton broth (MHB) at pH 7.2 or 5.8 or in artificial urine at pH 5.8. Bacteria were counted every 2 h until 10 h and at 24 h; the areas under the bacterial-count–versus–time curves were calculated. It was found that finafloxacin eliminated all strains within 2 h under all the conditions studied. At all doses studied, ciprofloxacin and levofloxacin were highly active against wild-type strains in MHB at pH 7.2 but lost activity in MHB, and particularly in urine, at pH 5.8. Viable counts of ESBL producers were reduced for 6 to 8 h by 3 log10 titers, but the bacteria regrew thereafter. Ciprofloxacin and levofloxacin were almost inactive against the SHV producer grown in artificial urine. We conclude that pharmacodynamic models using artificial urine may mirror the physiology of urinary tract infections more closely than those using conventional media. In contrast to ciprofloxacin and levofloxacin, finafloxacin gained activity in this model at an acidic pH, maintained activity in artificial urine, and was active against TEM and SHV producers. PMID:28193648
Dalhoff, A; Schubert, S; Vente, A
2017-05-01
The pharmacodynamics of finafloxacin, ciprofloxacin, and levofloxacin against extended-spectrum-β-lactamase (ESBL)-producing Enterobacteriaceae isolates were compared. Since quinolones lose activity in acidic media, and particularly in urine, their activities were tested in parallel under conventional conditions and in acidic artificial urine. For this purpose, TEM- and SHV-type ESBL-producing Escherichia coli and Klebsiella pneumoniae strains and their wild-type counterparts were exposed in a modified Grasso model to simulated concentrations of drugs in serum and urine following oral doses of either finafloxacin at 800 mg once a day (q.d.), immediate-release ciprofloxacin at 500 mg twice a day (b.i.d.), extended-release ciprofloxacin at 1,000 mg q.d., or levofloxacin at 500 or 750 mg q.d. The concentrations of the drugs in urine were fitted by compartmental modeling. Bacteria were cultivated in Mueller-Hinton broth (MHB) at pH 7.2 or 5.8 or in artificial urine at pH 5.8. Bacteria were counted every 2 h until 10 h and at 24 h; the areas under the bacterial-count-versus-time curves were calculated. It was found that finafloxacin eliminated all strains within 2 h under all the conditions studied. At all doses studied, ciprofloxacin and levofloxacin were highly active against wild-type strains in MHB at pH 7.2 but lost activity in MHB, and particularly in urine, at pH 5.8. Viable counts of ESBL producers were reduced for 6 to 8 h by 3 log 10 titers, but the bacteria regrew thereafter. Ciprofloxacin and levofloxacin were almost inactive against the SHV producer grown in artificial urine. We conclude that pharmacodynamic models using artificial urine may mirror the physiology of urinary tract infections more closely than those using conventional media. In contrast to ciprofloxacin and levofloxacin, finafloxacin gained activity in this model at an acidic pH, maintained activity in artificial urine, and was active against TEM and SHV producers. Copyright © 2017 Dalhoff et al.
da Mata, A D S P; da Silva Marques, D N; Silveira, J M L; Marques, J R O F; de Melo Campos Felino, E T; Guilherme, N F R P M
2009-04-01
To compare salivary pH changes and stimulation efficacy of two different gustatory stimulants of salivary secretion (GSSS). Portuguese Dental Faculty Clinic. Double blind randomized controlled trial. One hundred and twenty volunteers were randomized to two intervention groups. Sample sized was calculated using an alpha error of 0.05 and a beta of 0.20. Participants were randomly assigned to receive a new gustatory stimulant of secretory secretion containing a weaker malic acid, fluoride and xylitol or a traditionally citric acid-based one. Saliva collection was obtained by established methods at different times. The salivary pH of the samples was determined with a pH meter and a microelectrode. Salivary pH variations and counts of subjects with pH below 5.5 for over 1 min and stimulated salivary flow were the main outcome measures. Both GSSS significantly stimulated salivary output without significant differences between the two groups. The new gustatory stimulant of salivary secretion presented a risk reduction of 80 +/- 10.6% (95% CI) when compared with the traditional one. Gustatory stimulants of salivary secretion with fluoride, xylitol and lower acid content maintain similar salivary stimulation capacity while reducing significantly the dental erosion predictive potential.
Salivary pH and Buffering Capacity as Risk Markers for Early Childhood Caries: A Clinical Study.
Jayaraj, D; Ganesan, S
2015-01-01
The diagnostic utility of saliva is currently being explored in various branches of dentistry, remarkably in the field of caries research. This study was aimed to determine if assessment of salivary pH and buffering capacity would serve as reliable tools in risk prediction of early childhood caries (ECC). Paraffin-stimulated salivary samples were collected from 50 children with ECC (group I) and 50 caries free children (group II). Salivary pH and buffering capacity (by titration with 0.1 N hydrochloric acid) were assessed using a handheld digital pH meter in both groups. The data obtained were subjected to statistical analysis. Statistically, no significant difference was observed between both the groups for all salivary parameters assessed, except for the buffering capacity level at 150 μl titration of 0.1 N hydrochloric acid (p = 0.73; significant at 1% level). Salivary pH and buffering capacity may not serve as reliable markers for risk prediction of ECC. How to cite this article: Jayaraj D, Ganesan S. Salivary pH and Buffering Capacity as Risk Markers for Early Childhood Caries: A Clinical Study. Int J Clin Pediatr Dent 2015;8(3):167-171.
Role of enamel deminerlization and remineralization on microtensile bond strength of resin composite
Rizvi, Abbas; Zafar, Muhammad S.; Al-Wasifi, Yasser; Fareed, Wamiq; Khurshid, Zohaib
2016-01-01
Objective: This study is aimed to establish the microtensile bond strength of enamel following exposure to an aerated drink at various time intervals with/without application of remineralization agent. In addition, degree of remineralization and demineralization of tooth enamel has been assessed using polarized light microscopy. Materials and Methods: Seventy extracted human incisors split into two halves were immersed in aerated beverage (cola drink) for 5 min and stored in saliva until the time of microtensile bond testing. Prepared specimens were divided randomly into two study groups; remineralizing group (n = 70): specimens were treated for remineralization using casein phosphopeptides and amorphous calcium phosphate (CPP-ACP) remineralization agent (Recaldent™; GC Europe) and control group (n = 70): no remineralization treatment; specimens were kept in artificial saliva. All specimens were tested for microtensile bond strength at regular intervals (1 h, 1 days, 2 days, 1 week, and 2 weeks) using a universal testing machine. The results statistically analyzed (P = 0.05) using two-way ANOVA test. Results: Results showed statistically significant increase in bond strength in CPP-ACP tested group (P < 0.05) at all-time intervals. The bond strength of remineralizing group samples at 2 days (~13.64 megapascals [MPa]) is comparable to that of control group after 1 week (~12.44 MPa). Conclusions: CPP-ACP treatment of teeth exposed to an aerated drink provided significant increase in bond strength at a shorter interval compared to teeth exposed to saliva alone. PMID:27403057
Nair, U J; Nair, J; Friesen, M D; Bartsch, H; Ohshima, H
1995-05-01
The habit of betel quid chewing, common in South-East Asia and the South Pacific islands, is causally associated with an increased risk of oral cancer. Reactive oxygen species formed from polyphenolic betel quid ingredients and lime at alkaline pH have been implicated as the agents responsible for DNA and tissue damage. To determine whether hydroxyl radical (HO.) is generated in the human oral cavity during chewing of betel quid, the formation of o- and m-tyrosine from L-phenylalanine was measured. Both o- and m-tyrosine were formed in vitro in the presence of extracts of areca nut and/or catechu, transition metal ions such as Cu2+ and Fe2+ and lime or sodium carbonate (alkaline pH). Omission of any of these ingredients from the reaction mixture significantly reduced the yield of tyrosines. Hydroxyl radical scavengers such as ethanol, D-mannitol and dimethylsulfoxide inhibited the phenylalanine oxidation in a dose-dependent fashion. Five volunteers chewed betel quid consisting of betel leaf, areca nut, catechu and slaked lime (without tobacco). Their saliva, collected after chewing betel quid, contained high concentrations of p-tyrosine, but no appreciable amounts of o- or m-tyrosine. Saliva samples from the same subjects after chewing betel quid to which 20 mg phenylalanine had been added contained o- and m-tyrosine at concentrations ranging from 1010 to 3000 nM and from 1110 to 3140 nM respectively. These levels were significantly higher (P < 0.005) than those of subjects who kept phenylalanine in the oral cavity without betel quid, which ranged from 14 to 70 nM for o-tyrosine and from 10 to 35 nM for m-tyrosine. These studies clearly demonstrate that the HO. radical is formed in the human oral cavity during betel quid chewing and is probably implicated in the genetic damage that has been observed in oral epithelial cells of chewers.
Boz, M A; Sarıca, M; Yamak, U S
2017-04-01
1. This study investigates the slaughter, carcass and meat quality traits of artificially and naturally hatched geese in intensive and free-range production systems. 2. The study was conducted with 114 naturally hatched and 102 artificially hatched geese. From each replicate of the intensive and free-range systems, one female and one male goose were slaughtered at the ages of 14, 16 and 18 weeks (a total of 32 geese per slaughter week). 3. Artificially hatched geese had higher slaughter weights (5280 vs. 4404 g), carcass weights (3520 vs. 2863), dressing percentages (66.6-65.2% vs. 65.0-63.6%) and carcass part, feather and edible inner organ weights. The ratio of both edible inner organs and abdominal fat was higher in naturally hatched geese. Breast meat L*, a* and pH values and thigh meat dry matter values were higher in artificially hatched geese, whereas thigh meat b* and pH values were higher in naturally hatched geese. 4. Intensively reared geese had higher slaughter weights (4900 vs. 4783 g), carcass weights (3253 vs. 3130 g) and abdominal fat weights (280 vs. 250 g), as well as higher dressing percentages (66.3-64.9% vs. 65.3-63.9%). Breast meat b* and thigh meat L* values were higher in the intensive system, while breast and thigh pH values, dripping loss and cooking loss were higher in the free-range system. Water-holding capacity was higher in the intensive system. 5. In conclusion, artificially hatched, intensively reared geese had the highest slaughter weights; however, both artificially and naturally hatched geese raised in a free-range system reached acceptable slaughter weights and can thus be recommended for use with this type of production system.
Abbate, G M; Levrini, L; Caria, M P
2014-01-01
This study evaluated whether sodium bicarbonate applied on the oral mucosa through a new mucoadhesive spray (Cariex) could control a drop in salivary pH after a glucose rinse, and therefore enhance the buffering potential of saliva. A sample of 50 healthy adults was selected. At day 1, the measurement of salivary pH was performed in the lower fornix in correspondence with the lower molars. Each subject rinsed with 10 ml of a 10% glucose solution and then pH was monitored continually for 40 minutes. At day 2, the same experimental procedure was repeated and three shots of the spray were administered on the oral mucosa. The tested spray is composed of sodium bicarbonate, xylitol, and excipients. Without the mucoadhesive spray, salivary pH became significantly lower following the glucose rinse (p < 0.01). Following the spray, the time in which the pH remained lower than 6.0 was reduced statistically significantly (p < 0.01). A continual rise of salivary pH was observed for the 40 minutes in which the pH recording was performed. Conclusions: The use of a sodium bicarbonate spray on the mucosa was shown to control the lowering of salivary pH following carbohydrate consumption, and might therefore add to the prevention of caries and dental erosion.
Salivary pH as a marker of plasma adiponectin concentrations in Women.
Tremblay, Monique; Loucif, Yacine; Methot, Julie; Brisson, Diane; Gaudet, Daniel
2012-02-03
Plasma adiponectin is a significant correlate of the pro-inflammatory cardiometabolic risk profile associated with obesity and type 2 diabetes. Salivary pH is influenced by several cardiometabolic risk components such as inflammation, oxidation and numerous oral and systemic health modulators, including the menopausal status. This study aimed to assess the association between plasma adiponectin concentrations and salivary pH in women according to the menopausal status. Unstimulated saliva collection was performed in 151 Caucasian women of French-Canadian origin (53 premenopausal women (PMW) and 98 menopausal women (MW)). Student's t test, ANOVA and linear regression models were used to assess the association between plasma adiponectin concentrations and salivary pH. Plasma adiponectin levels increased as a function of salivary pH in the whole sample and among MW (r = 0.29 and r = 0.36, p < 0.001). The proportion of the variance of plasma adiponectin levels explained by the salivary pH (R2) was 10.8% (p < 0.001). Plasma adiponectin levels progressively increased across salivary pH quartiles (p = 0.005). These results suggest that salivary pH is a significant correlate of plasma adiponectin levels in women. With the increasing prevalence of type 2 diabetes and obesity, new technologies should be developed to more easily monitor health status, disease onset and progression. Salivary pH, a simple, inexpensive and non-invasive measure, could be a very promising avenue.
Hatim, Nadira A; Al-Tahho, Omar Zeno
2013-09-01
Evaluation of the effect of different beverages (tea with sugar, coffee with sugar, and Pepsi), and immersion time cycles (2, 4, and 12 weeks) on color change property, and dimensional change of Vertex Dental BV, Netherlands heat cured acrylic resin, recently modified Vertex Dental BV, Netherlands heat cured acrylic resin with additive (20 % banana oil), and Valplast(®) flexible resin (FR) denture base materials by using artificial saliva cycle. The total samples of this study for color, and dimensional changes were 360 samples, divided into three groups according to the type of the material, Vertex Dental BV, Netherlands heat cured acrylic resin, modified heat cured acrylic resin (Vertex with additive 20 % banana oil), and Valplast(®) FR groups, each group contains 120 samples. The thermal cycling used in this study was as follows: The samples were incubated in distilled water at 37 ± 1 °C for 2 days for conditioning. Then, the samples were immersed in beverage solutions for 10 min daily at 50 ± 1 °C temperature for tea, and coffee with sugar, while for Pepsi at 20 ± 1 °C. Then, the samples were immersed in artificial saliva at 37 ± 1 °C for 5 h, and 10 min. This cycle was repeated three times daily, and then the samples were immersed in distilled water at 22 ± 2 °C room temperature for 8 h at night. This cycle was repeated for 2, 4, and 12 weeks. At the end of each time period, the immersed samples were tested to evaluate the color change property. Descriptive statistics, ANOVA, and Duncan's multiple range tests were used to analyze the collected data. The results of this study showed that, in comparison between the materials at different times for colors L*a*b* properties, there were significant differences at P ≤ 0.05 except in color b* at 12 weeks, which showed no significant difference at P > 0.05 between materials. And there was a significant difference in dimensional change at P > 0.05 for different beverages, and times of immersion. The largest color, and dimensional changes were observed in the Valplast(®) FR, whereas tea was found to be the most chromatic agent, and showed unaccepted color change (ΔE ≤ 3.7) in vitro study as compared with coffee, Pepsi, and artificial saliva solutions.
Salivary flow rate and pH in patients with oral pathologies.
Foglio-Bonda, P L; Brilli, K; Pattarino, F; Foglio-Bonda, A
2017-01-01
Determine salivary pH and flow rate (FR) in a sample of 164 patients who came to Oral Pathology ambulatory, 84 suffering from oral lesions and 80 without oral lesions. Another aim was to evaluate factors that influence salivary flow rate. Subjects underwent clinical examination and completed an anamnestic questionnaire in order to obtain useful information that was used to classify participants in different groups. Unstimulated whole saliva (UWS) was collected using the spitting method at 11:00 am. The FR was evaluated with the weighing technique and a portable pHmeter, equipped with a microelectrode, was used to measure pH. Both univariate and classification (single and Random Forest) analyses were performed. The data analysis showed that FR and pH showed significant differences (p < 0.001) between patients with oral lesions (FR = 0.336 mL/min, pH = 6.69) and the ones without oral lesions (FR = 0.492 mL/min, pH = 6.96). By Random Forest, oral lesions and antihypertensive drugs were ranked in the top two among the evaluated variables to discretize subjects with FR = 0.16 mL/min. Our study shows that there is a relationship between oral lesions, antihypertensive drugs and alteration of pH and FR.
Radha, G; Swathi, V; Jha, Abhishek
2016-01-01
This study explores the association of disabilities and oral health. The aim of the study was to assess the salivary and plaque pH and oral health status of children with and without disabilities. A total of 100 schoolchildren (50 with disabilities and 50 without disabilities) were examined from 9 to 15 years age group. Saliva and plaque pH analysis were done to both the groups. Clinical data were collected on periodontal status, dental caries using WHO criteria. pH values of different groups, difference between the means were calculated using independent t-test, and frequency distribution was analyzed using Chi-square test. Statistical significance, P value was set at 0.05. Mean plaque and salivary pH scores were lesser (5.73 and 5.67) in children with intellectual disabilities (IDs) (P< 0.001). Subjects with disabilities had also statistically significant higher CPI scores and decayed, missing, and filled scores than their healthy counterparts (P< 0.001). There is a statistically significant difference in plaque and salivary pH among children with and without ID with lower plaque and salivary pH among children with ID. In addition to this, the oral health was also more compromised in children with ID, which confirms a need for preventive treatment for these children.
Hormonal responses of pilots to training flights: the effects of experience on apparent stress.
Otsuka, Yasutami; Onozawa, Akihiko; Miyamoto, Yoshinori
2006-04-01
The levels of urinary noradrenaline (NAd), adrenaline (Ad) and salivary cortisol (Cor) were determined in student and instructor pilots during Phase 1 (training with propeller engine; PH1), and Phase 2 (training with jet engine; PH2) flight training. The subjects in PH1 were 30 students and 33 instructors, and in PH2 were 17 students and 15 instructors. Urine and saliva were collected approximately 30 min before and 20 min after the flights. The ratio (post/preflight) of the hormonal levels was calculated to compare the students with the instructors and/or PH1 with PH2. In PH1, the levels of all three hormones for postflight were significantly higher than for preflight in students, and the ratios of all three hormones in students were significantly higher than in instructors. In PH2, the ratios of all three hormones for students and instructors did not differ significantly, and the ratios of Ad and Cor levels in students for PH2 were significantly lower than for PH1 (Ad: 1.64 +/- 0.10 vs. 2.23 +/- 0.14; Cor: 0.86 +/- 0.16 vs. 1.68 +/- 0.11, respectively). The results from PH1 clearly demonstrated that flight stress for students was significantly higher than for instructors. The ratios might be regarded as result of adaptation to flight stress in students. We conclude that the ratios of Ad and Cor levels are a good indicator of stress coping in student pilots.
Tarver, Matthew R; Shade, Richard E; Shukle, Richard H; Moar, William J; Muir, William M; Murdock, Larry M; Pittendrigh, Barry R
2007-05-01
The cowpea bruchid (Callosobruchus maculatus F.) (Chrysomelidae: Bruchini) is a major pest of stored cowpea grain. With limited available technologies for controlling the bruchid, transgenic cowpeas with bruchid resistance genes engineered into them could become the next management tools. An investigation was made of two different sets of potential transgenic insecticidal compounds using an artificial seed system: (i) CIP-PH-BT-J and recombinant egg white avidin, and (ii) avidin and wheat alpha-amylase inhibitor. CIP-PH-BT-J (0.1%; 1000 mg kg(-1)) and recombinant egg white avidin (0.006%; 60 mg kg(-1)) incorporated separately into artificial seeds caused 98.2 and 99% larval mortality rates respectively. Combining CIP-PH-BT-J and avidin in the same artificial seed provided additional mortality compared with each factor incorporated singly; no insects survived in seeds with the combined toxins. Similarly, when avidin and wheat alpha-amylase inhibitor (alphaAI) (1%; 10 g kg(-1)) were incorporated separately into artificial seeds, this caused 99.8 and 98% mortality respectively. However, in combination, avidin and alphaAI did not increase mortality, but they did cause a significant increase in developmental time of the cowpea bruchids. These results emphasize that the joint action of potential insecticidal compounds cannot be predicted from results obtained separately for each compound, and they suggest potential transgenes for further consideration.
Walliczek-Dworschak, Ute; Schöps, Franz; Feron, Gilles; Brignot, Helene; Hähner, Antje; Hummel, Thomas
2017-10-01
This study investigated the relation of the fungiform taste papillae density and saliva composition with the taste perception of patients suffering from diagnosed taste disorders. For this purpose, 81 patients and 40 healthy subjects were included. Taste was measured by means of regional and whole mouth chemosensory tests, and electrogustometry. Olfaction was assessed using the Sniffin Sticks. Fungiform papillae were quantified using the "Denver Papillae Protocol for Objective Analysis of Fungiform Papillae". In addition, salivary parameters [flow rate, total proteins, catalase, total anti-oxidative capacity (TAC), carbonic anhydrase VI (caVI), and pH] were determined and the Beck Depression Inventory was administered. Patients showed less taste papillae compared to healthy subjects. The number of papillae correlated with total taste strip score and salivary flow rate. Regarding salivary parameters, the flow rate, protein concentration, and TAC of patients were higher compared to controls. In addition, salivary flow rate, protease, caVI, and catalase values correlated with the summed taste strip score. Regarding various taste disorders, salty-dysgeusia patients showed the lowest taste test scores compared to those with bitter or metal-dysgeusia. Olfactory function of patients was significantly worse compared to healthy controls. This difference was most pronounced for ageusia patients. Compared to controls, patients also exhibited higher depressive symptoms. The density of fungiform papillae seemed to be positively associated with taste perception. Furthermore, patients exhibited changes in saliva composition (higher salivary flow rate, increased protein concentration, proteolysis, and TAC) compared to controls indicating that assessment of saliva may be critical for the diagnostic procedure in taste disorders. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Development of Co-based bulk metallic glasses as potential biomaterials.
Zhou, Zeyan; Wei, Qin; Li, Qiang; Jiang, Bingliang; Chen, You; Sun, Yanfei
2016-12-01
A new series of Co80-x-yCrxMoyP14B6 (x=5 y=5; x=5 y=10; x=10 y=10, all values in at.%) bulk metallic glasses (BMGs) with a maximum diameter of 1.5mm has been developed for using them as potential bio-implant materials by a combination of fluxing treatment and J-quenching technique. The performance of the present Co-based BMGs in biomedical implant applications was investigated as compared to the CoCrMo biomedical alloy (ASTM F75) and 316L stainless steel (316L SS). The corrosion behavior of the samples was investigated in both Hank's solution (pH=7.4) and artificial saliva solution (pH=6.3) at 37°C employing electrochemical measurements. The results indicate that the Co-based BMGs exhibit much higher corrosion resistance in the simulated body solutions than that of 316L SS. Compared with the corrosion resistance of ASTM F75, that of Co70Cr5Mo5P14B6 and Co65Cr5Mo10P14B6 BMGs is found to be lower and that of Co60Cr10Mo10P14B6 BMG is higher. The concentrations of Co, Cr, and Mo ions released into the simulated body solutions from our Co-based BMGs after potentiodynamic polarization are significantly lower than that released from ASTM F75. The biocompatibility of the specimens was evaluated using an in vitro test of NIH3T3 cell culture in the specimen extraction media for 1, 3, 5, and 7days, revealing the non-cytotoxicity of the Co-based BMGs towards NIH3T3 cells. Moreover, examinations on the cell adhesion and growth on the surface of the specimens indicate that the Co-based BMGs exhibit better cell viability compared to ASTM F75 and 316L SS biomedical alloys. Copyright © 2016 Elsevier B.V. All rights reserved.
Titratable acidity of beverages influences salivary pH recovery.
Tenuta, Livia Maria Andaló; Fernández, Constanza Estefany; Brandão, Ana Carolina Siqueira; Cury, Jaime Aparecido
2015-01-01
A low pH and a high titratable acidity of juices and cola-based beverages are relevant factors that contribute to dental erosion, but the relative importance of these properties to maintain salivary pH at demineralizing levels for long periods of time after drinking is unknown. In this crossover study conducted in vivo, orange juice, a cola-based soft drink, and a 10% sucrose solution (negative control) were tested. These drinks differ in terms of their pH (3.5 ± 0.04, 2.5 ± 0.05, and 5.9 ± 0.1, respectively) and titratable acidity (3.17 ± 0.06, 0.57 ± 0.04 and < 0.005 mmols OH- to reach pH 5.5, respectively). Eight volunteers with a normal salivary flow rate and buffering capacity kept 15 mL of each beverage in their mouth for 10 s, expectorated it, and their saliva was collected after 15, 30, 45, 60, 90, and 120 s. The salivary pH, determined using a mini pH electrode, returned to the baseline value at 30 s after expectoration of the cola-based soft drink, but only at 90 s after expectoration of the orange juice. The salivary pH increased to greater than 5.5 at 15 s after expectoration of the cola drink and at 30 s after expectoration of the orange juice. These findings suggest that the titratable acidity of a beverage influences salivary pH values after drinking acidic beverages more than the beverage pH.
Computational strategy for quantifying human pesticide exposure based upon a saliva measurement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Timchalk, Charles; Weber, Thomas J.; Smith, Jordan N.
The National Research Council of the National Academies report, Toxicity Testing in the 21st Century: A Vision and Strategy, highlighted the importance of quantitative exposure data for evaluating human toxicity risk and noted that biomonitoring is a critical tool for quantitatively evaluating exposure from both environmental and occupational settings. Direct measurement of chemical exposures using personal monitoring provides the most accurate estimation of a subject’s true exposure, and non-invasive methods have also been advocated for quantifying the pharmacokinetics and bioavailability of drugs and xenobiotics. In this regard, there is a need to identify chemicals that are readily cleared in salivamore » at concentrations that can be quantified to support the implementation of this approach.. The current manuscript describes the use of computational modeling approaches that are closely coupled to in vivo and in vitro experiments to predict salivary uptake and clearance of xenobiotics. The primary mechanism by which xenobiotics leave the blood and enter saliva is thought to involve paracellular transport, passive transcellular diffusion, or trancellular active transport with the majority of drugs and xenobiotics cleared from plasma into saliva by passive diffusion. The transcellular or paracellular diffusion of unbound chemicals in plasma to saliva has been computational modeled using a combination of compartmental and physiologically based approaches. Of key importance for determining the plasma:saliva partitioning was the utilization of a modified Schmitt algorithm that calculates partitioning based upon the tissue composition, pH, chemical pKa and plasma protein-binding. Sensitivity analysis of key model parameters specifically identified that both protein-binding and pKa (for weak acids and bases) had the most significant impact on the determination of partitioning and that there were clear species dependent differences based upon physiological variance between rats and humans. Ongoing efforts are focused on extending this modeling strategy to an in vitro salivary acinar cell based system that will be utilized to experimentally determine and computationally predict salivary gland uptake and clearance for a broad range of xenobiotics. Hence, it is envisioned that a combination of salivary biomonitoring and computational modeling will enable the non-invasive measurement of both environmental and occupational exposure in human populations using saliva.« less
Effect of double-layer application on dentin bond durability of one-step self-etch adhesives.
Taschner, M; Kümmerling, M; Lohbauer, U; Breschi, L; Petschelt, A; Frankenberger, R
2014-01-01
The aim of this in vitro study was 1) to analyze the influence of a double-layer application technique of four one-step self-etch adhesive systems on dentin and 2) to determine its effect on the stability of the adhesive interfaces stored under different conditions. Four different one-step self-etch adhesives were selected for the study (iBondSE, Clearfil S(3) Bond, XenoV(+), and Scotchbond Universal). Adhesives were applied according to manufacturers' instructions or with a double-layer application technique (without light curing of the first layer). After bonding, resin-dentin specimens were sectioned for microtensile bond strength testing in accordance with the nontrimming technique and divided into 3 subgroups of storage: a) 24 hours (immediate bond strength, T0), b) six months (T6) in artificial saliva at 37°C, or c) five hours in 10 % NaOCl at room temperature. After storage, specimens were stressed to failure. Fracture mode was assessed under a light microscope. At T0, iBond SE showed a significant increase in microtensile bond strength when the double-application technique was applied. All adhesive systems showed reduced bond strengths after six months of storage in artificial saliva and after storage in 10% NaOCl for five hours; however at T6, iBond SE, Clearfil S(3) Bond, and XenoV(+) showed significantly higher microtensile bond strength results for the double-application technique compared with the single-application technique. Scotchbond Universal showed no difference between single- or double-application, irrespective of the storage conditions. The results of this study show that improvements in bond strength of one-step self-etch adhesives by using the double-application technique are adhesive dependent.
A caffeine-maltodextrin mouth rinse counters mental fatigue.
Van Cutsem, Jeroen; De Pauw, Kevin; Marcora, Samuele; Meeusen, Romain; Roelands, Bart
2018-04-01
Mental fatigue is a psychobiological state caused by prolonged periods of demanding cognitive activity that has negative implications on many aspects in daily life. Caffeine and carbohydrate ingestion have been shown to be able to reduce these negative effects of mental fatigue. Intake of these substances might however be less desirable in some situations (e.g., restricted caloric intake, Ramadan). Rinsing caffeine or glucose within the mouth has already been shown to improve exercise performance. Therefore, we sought to evaluate the effect of frequent caffeine-maltodextrin (CAF-MALT) mouth rinsing on mental fatigue induced by a prolonged cognitive task. Ten males (age 23 ± 2 years, physical activity 7.3 ± 4.3 h/week, low CAF users) performed two trials. Participants first completed a Flanker task (3 min), then performed a 90-min mentally fatiguing task (Stroop task), followed by another Flanker task. Before the start and after each 12.5% of the Stroop task (eight blocks), subjects received a CAF-MALT mouth rinse (MR: 0.3 g/25 ml CAF: 1.6g/25 ml MALT) or placebo (PLAC: 25 ml artificial saliva). Self-reported mental fatigue was lower in MR (p = 0.017) compared to PLAC. Normalized accuracy (accuracy first block = 100%) was higher in the last block of the Stroop in MR (p = 0.032) compared to PLAC. P2 amplitude in the dorsolateral prefrontal cortex (DLPFC) decreased over time only in PLAC (p = 0.017). Frequent mouth rinsing during a prolonged and demanding cognitive task reduces mental fatigue compared to mouth rinsing with artificial saliva.
Dentine Tubule Occlusion by Novel Bioactive Glass-Based Toothpastes
Hill, Robert G.; Chen, Xiaojing
2018-01-01
There are numerous over-the-counter (OTC) and professionally applied (in-office) products and techniques currently available for the treatment of dentine hypersensitivity (DH), but more recently, the use of bioactive glasses in toothpaste formulations have been advocated as a possible solution to managing DH. Aim. The aim of the present study, therefore, was to compare several bioactive glass formulations to investigate their effectiveness in an established in vitro model. Materials and Methods. A 45S5 glass was synthesized in the laboratory together with several other glass formulations: (1) a mixed glass (fluoride and chloride), (2) BioMinF, (3) a chloride glass, and (4) an amorphous chloride glass. The glass powders were formulated into five different toothpaste formulations. Dentine discs were sectioned from extracted human teeth and prepared for the investigation by removing the cutting debris (smear layer) following sectioning using a 6% citric acid solution for 2 minutes. Each disc was halved to provide test and control halves for comparison following the brushing of the five toothpaste formulations onto the test halves for each toothpaste group. Following the toothpaste application, the test discs were immersed in either artificial saliva or exposed to an acid challenge. Results. The dentine samples were analyzed using scanning electron microscopy (SEM), and observation of the SEM images indicated that there was good surface coverage following artificial saliva immersion. Furthermore, although the acid challenge removed the hydroxyapatite layer on the dentine surface for most of the samples, except for the amorphous chloride glass, there was evidence of tubular occlusion in the dentine tubules. Conclusions. The conclusions from the study would suggest that the inclusion of bioactive glass into a toothpaste formulation may be an effective approach to treat DH. PMID:29849637
De Oliveira, Ana Luísa Botta Martins; Botta, Ana Carolina; Campos, Juliana Álvares Duarte Bonini; Garcia, Patrícia Petromilli Nordi Sasso
2014-11-01
Composite resin is a dental material susceptible to color change over time which limits the longevity of restorations made with this material. The influence of light curing units and different fluoride mouthrinses on superficial morphology and color stability of a nanofilled composite resin was evaluated. Specimens (N = 150) were prepared and polished. The experimental groups were divided according to the type of light source (halogen and LED) and immersion media (artificial saliva, 0.05% sodium fluoride solution-manipulated, Fluordent Reach, Oral B, Fluorgard). Specimens remained in artificial saliva for 24-h baseline. For 60 days, they were immersed in solutions for 1 min. Color readout was taken at baseline and after 60 days of immersion. Surface morphology was analyzed by Scanning Electron Microscopy (SEM) after 60 days of immersion. Color change data were submitted to two-way Analysis of Variance and Tukey tests (α = 0.05). Surface morphology was qualitatively analyzed. The factor light source presented no significant variability (P = 0.281), the immersion media, significant variability (P < 0.001) and interaction between factors, no significant variability (P = 0.050). According to SEM observations, no difference was noted in the surface of the specimens polymerized by different light sources, irrespective of the immersion medium. It was concluded that the light source did not influence the color stability of composite, irrespective of the immersion media, and among the fluoride solutions analyzed, Fluorgard was the one that promoted the greatest color change, however, this was not clinically perceptible. The immersion media did not influence the morphology of the studied resin. © 2014 Wiley Periodicals, Inc.
Anand, Ashish; Sharma, Arun; Kumar, Piush; Sandhu, Meera; Sachdeva, Shobhit; Sachdev, Vinod
2015-01-01
The aim of the study was to compare and evaluate the in vitro biodegradation of nickel and chromium from space maintainers, made of three different companies, i.e (Dantaurum, Rocky mountain and Dtech) in artificial saliva. The study comprised of 30 space maintainers out of which 10 were fabricated using Dantaurum, 10 using Rocky mountain and 10 using Dtech band materials. Stainless steel wire (Dantaurum, Rocky mountain and Konark) was used for making loops and Leone solder and flux was used for soldering. Each group was further divided into four subgroups containing 1, 2, 3 and 4 space maintainers respectively. The space maintainers in each subgroup were placed in separate glass beakers containing 100 ml of artificial saliva at 37°C for 4 weeks. Salivary samples from each beaker was analyzed for nickel and chromium ions separately on days 1, 7, 14, 21 and 28 days using inductively coupled plasma-optical emission spectrophotometer. Total release of nickel and chromium from all band and loop space maintainers ranged from 0.020 to 1.524 ppm and 0.002 to 0.289 ppm respectively. The release of nickel and chromium between the groups and within the groups was not significant (p < 0.5). There was no substantial release of nickel and chromium from space maintainers made of Dantaurum, Rocky mountain and Dtech which could cause any toxicity. How to cite this article: Anand A, Sharma A, Kumar P, Sandhu M, Sachdeva S, Sachdev V. A Comparative Study of Biodegradation of Nickel and Chromium from Space Maintainers: An in vitro Study. Int J Clin Pediatr Dent 2015; 8(1):37-41.
Rathi, Nilesh; Baid, Rutika; Baliga, Sudhindra; Thosar, Nilima
2017-04-01
To evaluate and compare the microhardness of deciduous teeth treated with nano-hydroxyapatite and calcium sucrose phosphate after iron drop exposure. Twenty healthy anterior deciduous teeth were collected and stored in 0.9% saline solution at room temperature. All the teeth were immersed in artificial saliva in an incubator shaker at 37° for an hour and then subjected to Vickers microhardness test at 100g load for 5 seconds. The teeth were then immersed in iron drop for 5 minutes, twice daily, rinsed with distilled water and kept in artificial saliva. This procedure was repeated for 7 days and teeth were subjected to microhardness testing. Further, the teeth were divided in two groups, each group containing 10 teeth. In group I, nanohydroxyapatite preparation and in group II, calcium sucrose phosphate were applied for 10 minutes, twice daily for 7 days and subjected again to microhardness testing again. Vickers microhardness analysis revealed that iron drop exposure to teeth caused significant decrease in microhardness ( p <0.05). Application of nanohydroxyapatite preparation in Group I showed significantly increased enamel microhardness (206.90) than that after iron drop exposure. Similarly, application of calcium sucrose phosphate in Group II showed significantly increased enamel microhardness (200.89) than that after iron drop exposure. Statistical difference was seen between the two groups, with nanohydroxyapatite preparation showing increased microhardness than calcium sucrose phosphate. Nanohydroxyapatite preparation and calcium sucrose phosphate have remineralizing effect over teeth affected by acid challenge of iron drops, nanohydroxyapatite preparation showing better results than calcium sucrose phosphate. Key words: Iron drops, Nanohydroxyapaptite, calcium sucrose phosphate, anticay.
Effects of a bleaching agent with calcium on bovine enamel
Alexandrino, Larissa; Gomes, Yasmin; Alves, Eliane; Costi, Hilton; Rogez, Hervé; Silva, Cecy
2014-01-01
Objective: This in vitro study analyzed the effects of a bleaching treatment containing 35% hydrogen peroxide (HP) with or without calcium on bovine enamel, using the Knoop hardness number (KHN), tristimulus colorimetry (TC), and scanning electron microscopy. Materials and Methods: Forty-five specimens were randomly divided into groups (n = 5), which included artificial saliva (negative control [NC]), 35% HP (positive control [PC]), and 35% HP Blue Calcium (HP Blue). The specimens were subjected to three bleaching sessions. During the sessions, the specimens were immersed in artificial saliva at 37°C. Before and after bleaching, KHN tests were conducted using a force of 25 gf for 5 s. TC was performed using the CIE-L*a*b* system and readouts were obtained at the following 4 time points: Before the bleaching treatment; after the first session, the second session, and the third session. The specimens were dehydrated and coated with gold, and the photomicrographs were analyzed in a double-blind manner with a LEO microscope. Results: Using one-way analysis of variance and Tukey's test (P < 0.05), a statistically significant difference was identified between the initial and final mean KHNs of the NC and PC groups, while the initial and final mean KHNs were not significantly different in the HP Blue group. The final mean values of ΔE, ΔL, and Δb of the PC and HP Blue groups were significantly higher than the initial values (P < 0.01 for both). The photomicrographs revealed no differences among the groups. Conclusions: Therefore, treatment with HP Blue prevented changes in the KHN without reducing the efficacy of bleaching. PMID:25202210
Effect of Bleaching Mouthwash on Force Decay of Orthodontic Elastomeric Chains.
Behnaz, Mohammad; Namvar, Fatemeh; Sohrabi, Setareh; Parishanian, Mina
2018-02-01
Force decay elastomeric chains are significant, and it is a clinical problem. The aim of this study was to evaluate the effects of bleaching agent in the mouthwash on the force decay of orthodontic chains. In this experimental study, 160 gray closed elastomeric chains were randomly divided into three groups (one control and two test groups). Four loops of chains were stretched for 25 mm on custom-made jig. Control group specimens were immersed in artificial saliva during the test period. Test group specimens were immersed twice a day for 30 seconds in the whitening (LISTERINE® HEALTHY WHITE™) and daily sodium fluoride (LISTERINE® TOTAL CARE ZERO) mouthwashes. All specimens were immersed in artificial saliva at 37°C. Force was measured at different time points (initial, 1, 7, 14, 21, 28 days). Statistical analysis was performed by two-way analysis of variance (ANOVA) and Bonferroni methods (a = 0.05). Force of elastomeric chains was decreased dramatically in all groups during the experiment. After 24 hours, force was decreased by 42.18, 48.34, and 53.38% in control group, daily, and bleaching mouthwash groups respectively. The corresponding numbers after 4 weeks were 66.30, 76.73, and 86.48. The difference between three groups at days 1 and 28 was statistically significant (p < 0.05). Within the limitations of the current in vitro study, bleaching and sodium fluoride mouthwashes could cause force decay of orthodontic elastomeric chains. Whitening mouthwash is more weakening for elastomeric chains. Use of whitening mouthwash by orthodontic patients could decrease the force of elastomeric chains, so it could be recommended to use them for a short time.
Nano-graphene oxide incorporated into PMMA resin to prevent microbial adhesion.
Lee, Jung-Hwan; Jo, Jeong-Ki; Kim, Dong-Ae; Patel, Kapil Dev; Kim, Hae-Won; Lee, Hae-Hyoung
2018-04-01
Although polymethyl methacrylate (PMMA) is widely used as a dental material, a major challenge of using this substance is its poor antimicrobial (anti-adhesion) effects, which increase oral infections. Here, graphene-oxide nanosheets (nGO) were incorporated into PMMA to introduce sustained antimicrobial-adhesive effects by increasing the hydrophilicity of PMMA. After characterizing nGO and nGO-incorporated PMMA (up to 2wt%) in terms of morphology and surface characteristics, 3-point flexural strength and hardness were evaluated. The anti-adhesive effects were determined for 4 different microbial species with experimental specimens and the underlying anti-adhesive mechanism was investigated by a non-thermal oxygen plasma treatment. Sustained antimicrobial-adhesive effects were characterized with incubation in artificial saliva for up to 28 days. The typical nanosheet morphology was observed for nGO. Incorporating nGO into PMMA roughened its surface and increased its hydrophilicity without compromising flexural strength or surface hardness. An anti-adhesive effect after 1h of exposure to microbial species in artificial saliva was observed in nGO-incorporated specimens, which accelerated with increasing levels of nGO without significant cytotoxicity to oral keratinocytes. Plasma treatment of native PMMA demonstrated that the antimicrobial-adhesive effects of nGO incorporation were at least partially due to increased hydrophilicity, not changes in the surface roughness. A sustained antimicrobial-adhesive property against Candida albicans was observed in 2% nGO for up to 28 days. The presence of sustained anti-adhesion properties in nGO-incorporated PMMA without loading any antimicrobial drugs suggests the potential usefulness of this compound as a promising antimicrobial dental material for dentures, orthodontic devices and provisional restorative materials. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Efficacy of Modified Bioactive Glass for Dentin Remineralization and Obstruction of Dentinal Tubules
Saffarpour, Mahshid; Tahriri, Mohammadreza; Zakerzadeh, Azadeh
2017-01-01
Objectives: This study assessed the efficacy of modified bioactive glass (MBG) for dentin remineralization and obstruction of dentinal tubules. Materials and Methods: Thirty-six dentin discs were made from 20 third molars and were stored in 12% lactic acid solution for two weeks to induce demineralization. The samples were divided into three groups (n=12): 1- BG, 2- BG modified with 5% strontium (Sr) and 3- BG modified with 10% Sr. After applying the BG, the samples were stored in artificial saliva for 7, 14 and 21 days. Attenuated Total Reflection-Fourier Transform Infrared Spectroscopy (ATR-FTIR), X-ray Diffraction (XRD) analysis, Scanning Electron Microscopy (SEM), and Energy-Dispersive X-ray (EDX) analysis were used to assess remineralization. Also, 6 dentin discs were divided into three groups of BG, BG modified with 5% Sr and BG modified with 10% Sr, to examine tubular occlusion. The discs were etched using 0.5M of EDTA for two minutes and were stored in artificial saliva for 7 days. Changes in dentin surface morphology were evaluated under SEM. Results: Group 3 showed high rates of remineralization at days 7 and 14, although the rate decreased at day 21. Group 2 exhibited high rates of remineralization at days 7, 14 and 21. Dentinal tubules were partially occluded by BG and BG modified with 5% Sr, while they were almost completely obstructed after the use of BG modified with 10% Sr. Conclusions: Strontium increases remineralization. Addition of 10% Sr to BG enhances apatite formation; however, the apatite dissolves over time. Addition of 5% Sr to BG stabilizes the apatite lattice and increases the remineralization. PMID:29285031
Ribeiro, Ana Lúcia Roselino; Hammer, Peter; Vaz, Luís Geraldo; Rocha, Luís Augusto
2013-12-01
The main aim of this work was to assess the electrochemical behavior of new Ti35Nb5Zr and Ti35Nb10Zr alloys in artificial saliva at 37 °C to verify if they are indicated to be used as biomaterials in dentistry as alternatives to Ti6Al4V alloys in terms of corrosion protection efficiency of the material. Electrochemical impedance spectroscopy (EIS) experiments were carried out for different periods of time (0.5-216 h) in a three-electrode cell, where the working electrode (Ti alloys) was exposed to artificial saliva at 37 °C. The near-surface region of the alloys was investigated using x-ray photoelectron spectroscopy (XPS). All alloys exhibited an increase in corrosion potential with the immersion time, indicating the growth and stabilization of the passive film. Ti35Nb5Zr and Ti6Al4V alloys had their EIS results interpreted by a double-layer circuit, while the Ti35Nb10Zr alloy was modeled by a one-layer circuit. In general, the new TiNbZr alloys showed similar behavior to that observed for the Ti6Al4V. XPS results suggest, in the case of the TiNbZr alloys, the presence of a thicker passive layer containing a lower fraction of TiO2 phase than that of Ti6Al4V. After long-term immersion, all alloys develop a calcium phosphate phase on the surface. The new TiNbZr alloys appear as potential candidates to be used as a substitute to Ti6Al4V in the manufacturing of dental implant-abutment sets.
Duarte, Antônio R C; Neto, João P Silva; Souza, Júlio C M; Bonachela, Wellington C
2013-06-01
Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conexão®, (E) Emfils®, (I) INP®, (S) SIN®, and (T) Titanium Fix®. The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20 Ncm using a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronic microscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions. © 2012 by the American College of Prosthodontists.
Effects of chemical composition on the corrosion of dental alloys.
Galo, Rodrigo; Ribeiro, Ricardo Faria; Rodrigues, Renata Cristina Silveira; Rocha, Luís Augusto; de Mattos, Maria da Glória Chiarello
2012-01-01
The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.
Tuna, Süleyman Hakan; Özçiçek Pekmez, Nuran; Kürkçüoğlu, Işin
2015-11-01
The effects of fabrication methods on the corrosion resistance of frameworks produced with Co-Cr alloys are not clear. The purpose of this in vitro study was to evaluate the electrochemical corrosion resistance of Co-Cr alloy specimens that were fabricated by conventional casting, milling, and laser sintering. The specimens fabricated with 3 different methods were investigated by potentiodynamic tests and electrochemical impedance spectroscopy in an artificial saliva. Ions released into the artificial saliva were estimated with inductively coupled plasma-mass spectrometry, and the results were statistically analyzed. The specimen surfaces were investigated with scanning electron microscopy before and after the tests. In terms of corrosion current and Rct properties, statistically significant differences were found both among the means of the methods and among the means of the material groups (P<.05). With regard to ions released, a statistically significant difference was found among the material groups (P<.05); however, no difference was found among the methods. Scanning electron microscopic imaging revealed that the specimens produced by conventional casting were affected to a greater extent by etching and electrochemical corrosion than those produced by milling and laser sintering. The corrosion resistance of a Co-Cr alloy specimens fabricated by milling or laser sintering was greater than that of the conventionally cast alloy specimens. The Co-Cr specimens produced by the same method also differed from one another in terms of corrosion resistance. These differences may be related to the variations in the alloy compositions. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Souza, Júlio C. M.; Silva, Joel B.; Aladim, Andrea; Carvalho, Oscar; Nascimento, Rubens M.; Silva, Filipe S.; Martinelli, Antonio E.; Henriques, Bruno
2016-01-01
Background: Glass-ionomer cements perform a protective effect on the dentin-pulp complex considering the F ions release and chemical bonding to the dental structures. On the other hand, those materials have poor physic-mechanical properties in comparison with the restorative resin composite. The main aim of this work was to evaluate the influence of zirconia and/or alumina fillers on the microstructure and strength of a resin modified glass-ionomer cement after thermal cycling. Methods: An in vitro experimental study was carried out on 9 groups (n = 10) of cylindrical samples (6 x 4 mm) made from resin modified glass-ionomer (Vitremer, 3M, USA) with different contents of alumina and/or zirconia fillers. A nano-hybrid resin composite was tested as a control group. Samples were mechanically characterized by axial compressive tests and electron scanning microscopy (SEM) coupled to energy dispersive X-ray spectrophotometry (EDS), before and after thermal cycling. Thermal cycling procedures were performed at 3000, 6000 and 10000 cycles in Fusayama´s artificial saliva at 5 and 60 oC. Results: An improvement of compressive strength was noticed on glass-ionomer reinforced with alumina fillers in comparison with the commercial glass ionomer. SEM images revealed the morphology and distribution of alumina or zirconia in the microstructure of glass-ionomers. Also, defects such as cracks and pores were detected on the glass-ionomer cements. The materials tested were not affected by thermal cycling in artificial saliva. Conclusion: Addition of inorganic particles at nano-scale such as alumina can increase the mechanical properties of glass-ionomer cements. However, the presence of cracks and pores present in glass-ionomer can negatively affect the mechanical properties of the material because they are areas of stress concentration. PMID:27053969
Metal release profiles of orthodontic bands, brackets, and wires: an in vitro study.
Wendl, B; Wiltsche, H; Lankmayr, E; Winsauer, H; Walter, A; Muchitsch, A; Jakse, N; Wendl, M; Wendl, T
2017-11-01
The present study evaluated the temporal release of Co Cr, Mn, and Ni from the components of a typical orthodontic appliance during simulated orthodontic treatment. Several commercially available types of bands, brackets, and wires were exposed to an artificial saliva solution for at least 44 days and the metals released were quantified in regular intervals using inductively coupled plasma quadrupole mass spectrometry (ICP-MS, Elan DRC+, Perkin Elmer, USA). Corrosion products encountered on some products were investigated by a scanning electron microscope equipped with an energy dispersive X-ray microanalyzer (EDX). Bands released the largest quantities of Co, Cr, Mn, and Ni, followed by brackets and wires. Three different temporal metal release profiles were observed: (1) constant, though not necessarily linear release, (2) saturation (metal release stopped after a certain time), and (3) an intermediate release profile that showed signs of saturation without reaching saturation. These temporal metal liberation profiles were found to be strongly dependent on the individual test pieces. The corrosion products which developed on some of the bands after a 6-month immersion in artificial saliva and the different metal release profiles of the investigated bands were traced back to different attachments welded onto the bands. The use of constant release rates will clearly underestimate metal intake by the patient during the first couple of days and overestimate exposure during the remainder of the treatment which is usually several months long. While our data are consistent with heavy metal release by orthodontic materials at levels well below typical dietary intake, we nevertheless recommend the use of titanium brackets and replacement of the band with a tube in cases of severe Ni or Cr allergy.
Effect of Energy Drinks on Discoloration of Silorane and Dimethacrylate-Based Composite Resins
Ahmadizenouz, Ghazaleh; Esmaeili, Behnaz; Ahangari, Zohreh; Khafri, Soraya; Rahmani, Aghil
2016-01-01
Objectives: This study aimed to assess the effects of two energy drinks on color change (ΔE) of two methacrylate-based and a silorane-based composite resin after one week and one month. Materials and Methods: Thirty cubic samples were fabricated from Filtek P90, Filtek Z250 and Filtek Z350XT composite resins. All the specimens were stored in distilled water at 37°C for 24 hours. Baseline color values (L*a*b*) of each specimen were measured using a spectrophotometer according to the CIEL*a*b* color system. Ten randomly selected specimens from each composite were then immersed in the two energy drinks (Hype, Red Bull) and artificial saliva (control) for one week and one month. Color was re-assessed after each storage period and ΔE values were calculated. The data were analyzed using the Kruskal Wallis and Mann–Whitney U tests. Results: Filtek Z250 composite showed the highest ΔE irrespective of the solutions at both time points. After seven days and one month, the lowest ΔE values were observed in Filtek Z350XT and Filtek P90 composites immersed in artificial saliva, respectively. The ΔE values of Filtek Z250 and Z350XT composites induced by Red Bull and Hype energy drinks were not significantly different. Discoloration of Filtek P90 was higher in Red Bull energy drink at both time points. Conclusions: Prolonged immersion time in all three solutions increased ΔE values of all composites. However, the ΔE values were within the clinically acceptable range (<3.3) at both time points. PMID:28127318
Daood, Umer; Swee Heng, Chan; Neo Chiew Lian, Jennifer; Fawzy, Amr S
2015-06-26
To modify two-step experimental etch-and-rinse dentin adhesive with different concentrations of riboflavin and to study its effect on the bond strength, degree of conversion, along with resin infiltration within the demineralized dentin substrate, an experimental adhesive-system was modified with different concentrations of riboflavin (m/m, 0, 1%, 3%, 5% and 10%). Dentin surfaces were etched with 37% phosphoric acid, bonded with respective adhesives, restored with restorative composite-resin, and sectioned into resin-dentin slabs and beams to be stored for 24 h or 9 months in artificial saliva. Micro-tensile bond testing was performed with scanning electron microscopy to analyse the failure of debonded beams. The degree of conversion was evaluated with Fourier transform infrared spectroscopy (FTIR) at different time points along with micro-Raman spectroscopy analysis. Data was analyzed with one-way and two-way analysis of variance followed by Tukey's for pair-wise comparison. Modification with 1% and 3% riboflavin increased the micro-tensile bond strength compared to the control at 24 h and 9-month storage with no significant differences in degree of conversion (P<0.05). The most predominant failure mode was the mixed fracture among all specimens except 10% riboflavin-modified adhesive specimens where cohesive failure was predominant. Raman analysis revealed that 1% and 3% riboflavin adhesives specimens showed relatively higher resin infiltration. The incorporation of riboflavin in the experimental two-step etch-and-rinse adhesive at 3% (m/m) improved the immediate bond strengths and bond durability after 9-month storage in artificial saliva without adversely affecting the degree of conversion of the adhesive monomers and resin infiltration.
Brandão, Gustavo Antônio Martins; Simas, Rafael Menezes; de Almeida, Leandro Moreira; da Silva, Juliana Melo; Meneghim, Marcelo de Castro; Pereira, Antonio Carlos; de Almeida, Haroldo Amorim; Brandão, Ana Maria Martins
2013-01-01
To evaluate the in vitro ionic degradation and slot base corrosion of metallic brackets subjected to brushing with dentifrices, through analysis of chemical composition by Energy Dispersive Spectroscopy (EDS) and qualitative analysis by Scanning Electron Microscopy (SEM). Thirty eight brackets were selected and randomly divided into four experimental groups (n = 7). Two groups (n = 5) worked as positive and negative controls. Simulated orthodontic braces were assembled using 0.019 x 0.025-in stainless steel wires and elastomeric rings. The groups were divided according to surface treatment: G1 (Máxima Proteção Anticáries®); G2 (Total 12®); G3 (Sensitive®); G4 (Branqueador®); Positive control (artificial saliva) and Negative control (no treatment). Twenty eight brushing cycles were performed and evaluations were made before (T0) and after (T1) experiment. The Wilcoxon test showed no difference in ionic concentrations of titanium (Ti), chromium (Cr), iron (Fe) and nickel (Ni) between groups. G2 presented significant reduction (p < 0.05) in the concentration of aluminium ion (Al). Groups G3 and G4 presented significant increase (p < 0.05) in the concentration of aluminium ion. The SEM analysis showed increased characteristics indicative of corrosion on groups G2, G3 and G4. The EDS analysis revealed that control groups and G1 did not suffer alterations on the chemical composition. G2 presented degradation in the amount of Al ion. G3 and G4 suffered increase in the concentration of Al. The immersion in artificial saliva and the dentifrice Máxima Proteção Anticáries® did not alter the surface polishing. The dentifrices Total 12®, Sensitive® and Branqueador® altered the surface polishing.
Liu, Jia-Kuang; Lee, Tzer-Min; Liu, I-Hua
2011-08-01
For orthodontic applications, equiatomic nickel-titanium (NiTi) wires are used to level and align the teeth under bending conditions in the oral environment for long periods. The aim of study was to investigate the influence of bending stress on the nickel release of commercial NiTi orthodontic wires in vitro, simulating the intraoral environment as realistically as possible. Two types of as-received orthodontic NiTi wires, free of performed internal stress, were immersed in artificial saliva. Half of the NiTi wires were exposed to continuous bending stress throughout the 14-day experimental period. The stressed NiTi wires exhibited substantial increases in the nickel release compared with the unstressed specimens during all experimental periods. The highest dissolution rate during the 0 to 1 day incubation period was observed for all stressed specimens. However, a slight increase of nickel released as a function of time was observed in the 3 groups of stressed specimens after 3 days of immersion. For the stressed specimens, it was hypothesized that the bending stress would induce buckling or cracking of the protective oxide film of the NiTi wires. In this study, the mechanism of nickel release was the underlying metal surface reacting with the surrounding environment. The results indicated that bending stress influences the nickel release of NiTi wires. The factor of loading condition with respect to corrosion behavior and passive film should be considered in view of the widespread use of NiTi wires for dental devices. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.