Qiu, Weiqiang; Liu, Ziyuan; Zhang, Zhihong; Ao, Mingxin; Li, Xuemin; Wang, Wei
2012-01-01
This study aimed to compare the effects of treatment with punctal plugs versus artificial tears on visual function and tear film stability for dry eye. A total of 56 consecutive eyes of 28 dry eye patients observed at our clinic from May to October in 2009 were divided into two groups. One group (32 eyes of 16 patients) was treated with artificial tears, and punctal plugs were used in the other group (24 eyes of 12 patients). A questionnaire was used in these patients before treatment and was repeated 2 weeks after treatment. Fluorescent staining for tear film break-up time (BUT), the Schirmer test I (STI), and contrast sensitivity was performed at the same time. The questionnaire indicated that all patients complained about the uncomfortable symptoms associated with dry eye. These symptoms were relieved after the application of artificial tears or punctal plugs, and there was no significant difference between these two groups. We found that the corneal fluorescent staining disappeared after treatment. The BUT was improved significantly after treatment in both groups, but the improvement was greater in patients who received punctal plugs than those that received artificial tears. There was no remarkable change in the STI in the artificial tears group, but a significant change was observed in the punctal plugs group. The contrast sensitivities were greatly improved in simulated daylight, night, and glare disability conditions after treatment with artificial tears and punctal plugs. However, the changes in contrast sensitivity did not significantly differ between groups. Both artificial tears and punctal plugs relieved dry eye symptoms, repaired corneal lesions, enhanced tear film stability, and improved contrast sensitivity. Punctal plugs could improve tear film stability and elongate the BUT better than artificial tears.
Artificial tears potpourri: a literature review
Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F
2014-01-01
Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. PMID:25114502
Ahn, Somin; Eom, Youngsub; Kang, Boram; Park, Jungboung; Lee, Hyung Keun; Kim, Hyo Myung; Song, Jong Suk
2018-05-01
To evaluate the effects of menthol-containing artificial tears on tear stimulation and ocular surface integrity in normal and dry eye rat models. A total of 54 male Lewis rats were used. The levels of tear secretion and tear MUC5AC concentrations were compared between the menthol-containing artificial tear-treated group (menthol group) and the vehicle-treated group (vehicle group). The groups were compared after a single instillation to evaluate the immediate effects, and after repeated instillation (five times a day for 5 days) to evaluate the longer-term effects. Tear lactate dehydrogenase (LDH) activity was measured to evaluate eye drop instillation-induced ocular surface damage. The effects of menthol-containing artificial tears were also evaluated in a dry eye rat model. After a single instillation of menthol-containing artificial tears, tear secretion increased from 4.37 (±0.75) mm at baseline to 7.37 (±1.60) mm. However, after repeated instillations, the effects of tear stimulation decreased. The tear MUC5AC concentration was significantly lower in the menthol group than in the vehicle group after a single instillation, but not after repeated instillation. However, the tear LDH concentration was significantly increased in the menthol group after repeated instillation. In the dry eye rat model, the extent of menthol-induced tear stimulation was reduced. Menthol-containing artificial tears increased tear secretion, but lowered the tear MUC5AC concentration. Menthol-induced tear stimulation was reduced after repeated instillation for 5 days and in the dry eye rat model. Conversely, repeated instillation of menthol-induced ocular surface damage, resulting in increased tear LDH activity.
Incomplete response to artificial tears is associated with features of neuropathic ocular pain.
Galor, Anat; Batawi, Hatim; Felix, Elizabeth R; Margolis, Todd P; Sarantopoulos, Konstantinos D; Martin, Eden R; Levitt, Roy C
2016-06-01
Artificial tears are first-line therapy for patients with dry eye symptoms. It is not known, however, which patient factors associate with a positive response to therapy. The purpose of this study was to evaluate whether certain ocular and systemic findings are associated with a differential subjective response to artificial tears. Cross-sectional study of 118 individuals reporting artificial tears use (hypromellose 0.4%) to treat dry eye-associated ocular pain. An evaluation was performed to assess dry eye symptoms (via the dry eye questionnaire 5 and ocular surface disease index), ocular and systemic (non-ocular) pain complaints and ocular signs (tear osmolarity, tear breakup time, corneal staining, Schirmer testing with anaesthesia, and eyelid and meibomian gland assessment). The main outcome measures were factors associated with differential subjective response to artificial tears. By self-report, 23 patients reported no improvement, 73 partial improvement and 22 complete improvement in ocular pain with artificial tears. Patients who reported no or partial improvement in pain with artificial tears reported higher levels of hot-burning ocular pain and sensitivity to wind compared with those with complete improvement. Patients were also asked to rate the intensity of systemic pain elsewhere in the body (other than the eye). Patients who reported no or incomplete improvement with artificial tears had higher systemic pain scores compared with those with complete improvement. Both ocular and systemic (non-ocular) pain complaints are associated with a differential subjective response to artificial tears. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
[Clinical characteristics of short tear film breakup time (BUT) -type dry eye].
Yamamoto, Yuji; Yokoi, Norihiko; Higashihara, Hisayo; Inagaki, Kayoko; Sonomura, Yukiko; Komuro, Aoi; Kinoshita, Shigeru
2012-12-01
To evaluate the clinical characteristics and management of short tear film breakup time (BUT) -type dry eye. Clinical background and post-treatment changes of symptoms in 77 patients with short BUT -type dry eye were investigated. Treatment consisted of artificial-tear eye-drop instillation and, if necessary, the addition of a low-density-level steroid, hyaluronic acid, a low-density-level cyclopentolate prepared by ourselves and punctal plugs inserted into the upper and lower lacrimal puncta. There were three times more women than men among the patients, and the peak age of occurrence was in the twenties in the men and in the sixties in the women. Our findings show that visual display terminal (VDT) work, contact lens (CL) wear, and changes in the sex hormones may initiate subjective symptoms. Some patients had simultaneous conjunctivochalasis, allergic conjunctivitis, and meibomian gland dysfunction. Nineteen patients (24.7%) were effectively treated with eye-drop instillation alone. Thirty-seven patients (48.1%) required punctal-plug insertion, which was completely effective in only 8 of them (21.6%). Mainly young men and menopausal women contract short BUT -type dry eye. Changes in sex hormones, VDT work and CL wear may be causal, and the disease cannot be controlled by eyedrop and punctal-plug treatment alone.
Over the counter (OTC) artificial tear drops for dry eye syndrome.
Pucker, Andrew D; Ng, Sueko M; Nichols, Jason J
2016-02-23
Over the counter (OTC) artificial tears historically have been the first line of treatment for dry eye syndrome and dry eye-related conditions like contact lens discomfort, yet currently we know little regarding the overall efficacy of individual, commercially available artificial tears. This review provides a much needed meta-analytical look at all randomized and quasi-randomized clinical trials that have analyzed head-to-head comparisons of OTC artificial tears. To evaluate the effectiveness and toxicity of OTC artificial tear applications in the treatment of dry eye syndrome compared with another class of OTC artificial tears, no treatment, or placebo. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2015, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2015), EMBASE (January 1980 to December 2015), Latin American and Caribbean Health Sciences (LILACS) (January 1982 to December 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the US Food and Drugs Administration (FDA) website (www.fda.gov). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 4 December 2015. We searched reference lists of included trials for any additional trials not identified by the electronic searches. This review includes randomized controlled trials with adult participants who were diagnosed with dry eye, regardless of race and gender. We included trials in which the age of participants was not reported, and clinical trials comparing OTC artificial tears with another class of OTC artificial tears, placebo, or no treatment. This review did not consider head-to-head comparisons of artificial tears with another type of dry-eye therapy. We followed the standard methodological procedures expected by Cochrane. Two authors independently screened the search results, reviewed full-text copies for eligibility, examined risk of bias, and extracted data. We performed meta-analysis for trials that compared similar interventions and reported comparable outcomes with sufficient data. We summarized all other included trial results in the text. We included 43 randomized controlled trials (3497 participants with dry eye). Due to the heterogeneity of study characteristics among the included trials with respect to types of diagnostic criteria, interventions, comparisons, and measurements taken, our ability to perform meta-analyses was limited. The review found that, in general, there was uncertainty whether different OTC artificial tears provide similar relief of signs and symptoms when compared with each other or placebo. Nevertheless, we found that 0.2% polyacrylic acid-based artificial tears were consistently more effective at treating dry eye symptoms than 1.4% polyvinyl alcohol-based artificial tears in two trials assessing this comparison (175 participants). All other included artificial tears produced contradictory between-group results or found no between-group differences. Our review also found that OTC artificial tears may be generally safe, but not without adverse events. Overall, we assessed the quality of evidence as low due to high risks of bias among included trials and poor reporting of outcome measures which were insufficient for quantitative analysis. Furthermore, we identified an additional 18 potentially eligible trials that were reported only in clinical trial registers with no associated results or publications. These trials reportedly enrolled 2079 total participants for whom no data are available. Such lack of reporting of trial results represents a high risk of publication bias. OTC artificial tears may be safe and effective means for treating dry eye syndrome; the literature indicates that the majority of OTC artificial tears may have similar efficacies. This conclusion could be greatly skewed by the inconsistencies in study designs and inconsistencies in reporting trial results. Additional research is therefore needed before we can draw robust conclusions about the effectiveness of individual OTC artificial tear formulations.
Demiryay, Elvan; Yaylali, Volkan; Cetin, Ebru Nevin; Yildirim, Cem
2011-09-01
The aim was to compare the effects of topical cyclosporine A and artificial tears combination with artificial tears alone in patients with dysfunctional tear syndrome (DTS). Forty-two eyes of 42 patients with DTS were enrolled in the study. The inclusion criteria for the study were Schirmer I (without anesthesia) scores below 10 mm/5 min and tear film break-up time (BUT) below 10 sec. The patients were randomly divided into two groups. The study group (22 patients) underwent 0.05% cyclosporine A treatment twice a day and preservative-free artificial tears for four times a day for 4 months. The control group (20 patients) was administered only preservative-free artificial tears four times a day for 4 months. The BUT, Schirmer test scores, corneal fluorescein staining, conjunctival lissamine green staining, and goblet cell density derived by impression cytology were recorded before and after treatment in each group. In the study group, all parameters improved statistically significantly after treatment at the 4-month follow-up compared with the pretreatment values (P<0.001 for all). In the control group, corneal fluorescein staining (P<0.001) and conjunctival lissamine green staining (P=0.014) improved, but BUT and Schirmer scores did not change significantly after treatment. At the end of the 4-month follow-up, the study group demonstrated statistically significantly better BUT (P=0.020), Schirmer scores (P=0.002), goblet cell density (P=0.006), corneal fluorescein staining (P=0.003), and conjunctival lissamine green staining (P=0.017) scores than did the control group. Topical cyclosporine A and artificial tears treatment significantly increases goblet cell density, decreases the signs of DTS, and improves ocular surface health.
Essa, Laika; Laughton, Deborah; Wolffsohn, James S
2018-02-01
To assess dry eye treatment with four preservative-free dry eye artificial tear treatments to facilitate evidence-based prescribing. A randomised, single masked crossover trial of Clinitas Soothe, Hyabak, Tears Again and TheraTears artificial tears was conducted on 50 symptomatic dry eye patients, aged 60.8±14.2years. At baseline and after trialling each treatment for 4 weeks, signs and symptoms were assessed using the Ocular Surface Disease Index (OSDI), non-invasive tear break-up time, fluorescein tear break-up time, tear meniscus height (TMH), Phenol Red test, lid-parallel conjunctival folds (LIPCOF), ocular surface staining, and lipid layer grading and osmolarity (baseline visit only). OSDI (p=0.002), LIPCOF (p=0.014) and conjunctival staining (p<0.001) significantly improved from baseline, however, the impact of each dry eye treatment on ocular symptoms and signs was similar. Clinitas Soothe and Hyabak were preferred by 34%/30% of participants, but only subjective comparison with the other drops influenced this choice. TheraTears was preferred (by 24%) by those with a lower baseline tear volume (p=0.01) and Tears Again (by 12%) by those with a thinner baseline lipid layer (p=0.04). The treatment that afforded the greatest improvement in clinical signs did not consistently match each individual's preferred treatment. If prescribed to a general dry eye population, the artificial tears performed similarly, improving symptoms and conjunctival signs. However, osmolarity balanced artificial tears were the preferred treatment in individuals with low baseline tear volume and lipisomal spray for individuals with a baseline lipid layer deficiency. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Facile Determination of Sodium Ion and Osmolarity in Artificial Tears by Sequential DNAzymes.
Kim, Eun Hye; Lee, Eun-Song; Lee, Dong Yun; Kim, Young-Pil
2017-12-07
Despite high relevance of tear osmolarity and eye abnormality, numerous methods for detecting tear osmolarity rely upon expensive osmometers. We report a reliable method for simply determining sodium ion-based osmolarity in artificial tears using sequential DNAzymes. When sodium ion-specific DNAzyme and peroxidase-like DNAzyme were used as a sensing and detecting probe, respectively, the concentration of Na⁺ in artificial tears could be measured by absorbance or fluorescence intensity, which was highly correlated with osmolarity over the diagnostic range ( R ² > 0.98). Our approach is useful for studying eye diseases in relation to osmolarity.
Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis
NITODA, EIRINI; LAVARIS, ANASTASIOS; LAIOS, KONSTANTINOS; ANDROUDI, SOPHIA; KALOGEROPOULOS, CHRIS D; TSATSOS, MICHAEL; DAMASKOS, CHRISTOS; GARMPIS, NIKOLAOS; MOSCHOS, MARILITA M
2018-01-01
Background/Aim: Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Patients and Methods: Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. Results: The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Conclusion: Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. PMID:29475928
Over the counter (OTC) artificial tear drops for dry eye syndrome
Pucker, Andrew D; Ng, Sueko M; Nichols, Jason J
2016-01-01
Background Over the counter (OTC) artificial tears historically have been the first line of treatment for dry eye syndrome and dry eye-related conditions like contact lens discomfort, yet currently we know little regarding the overall efficacy of individual, commercially available artificial tears. This review provides a much needed meta-analytical look at all randomized and quasi-randomized clinical trials that have analyzed head-to-head comparisons of OTC artificial tears. Objectives To evaluate the effectiveness and toxicity of OTC artificial tear applications in the treatment of dry eye syndrome compared with another class of OTC artificial tears, no treatment, or placebo. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2015, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2015), EMBASE (January 1980 to December 2015), Latin American and Caribbean Health Sciences (LILACS) (January 1982 to December 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the US Food and Drugs Administration (FDA) website (www.fda.gov). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 4 December 2015. We searched reference lists of included trials for any additional trials not identified by the electronic searches. Selection criteria This review includes randomized controlled trials with adult participants who were diagnosed with dry eye, regardless of race and gender. We included trials in which the age of participants was not reported, and clinical trials comparing OTC artificial tears with another class of OTC artificial tears, placebo, or no treatment. This review did not consider head-to-head comparisons of artificial tears with another type of dry-eye therapy. Data collection and analysis We followed the standard methodological procedures expected by Cochrane. Two authors independently screened the search results, reviewed full-text copies for eligibility, examined risk of bias, and extracted data. We performed meta-analysis for trials that compared similar interventions and reported comparable outcomes with sufficient data. We summarized all other included trial results in the text. Main results We included 43 randomized controlled trials (3497 participants with dry eye). Due to the heterogeneity of study characteristics among the included trials with respect to types of diagnostic criteria, interventions, comparisons, and measurements taken, our ability to perform meta-analyses was limited. The review found that, in general, there was uncertainty whether different OTC artificial tears provide similar relief of signs and symptoms when compared with each other or placebo. Nevertheless, we found that 0.2% polyacrylic acid-based artificial tears were consistently more effective at treating dry eye symptoms than 1.4% polyvinyl alcohol-based artificial tears in two trials assessing this comparison (175 participants). All other included artificial tears produced contradictory between-group results or found no between-group differences. Our review also found that OTC artificial tears may be generally safe, but not without adverse events. Overall, we assessed the quality of evidence as low due to high risks of bias among included trials and poor reporting of outcome measures which were insufficient for quantitative analysis. Furthermore, we identified an additional 18 potentially eligible trials that were reported only in clinical trial registers with no associated results or publications. These trials reportedly enrolled 2079 total participants for whom no data are available. Such lack of reporting of trial results represents a high risk of publication bias. Authors’ conclusions OTC artificial tears may be safe and effective means for treating dry eye syndrome; the literature indicates that the majority of OTC artificial tears may have similar efficacies. This conclusion could be greatly skewed by the inconsistencies in study designs and inconsistencies in reporting trial results. Additional research is therefore needed before we can draw robust conclusions about the effectiveness of individual OTC artificial tear formulations. PMID:26905373
Evaluation of a Novel Artificial Tear in the Prevention and Treatment of Dry Eye in an Animal Model.
She, Yujing; Li, Jinyang; Xiao, Bing; Lu, Huihui; Liu, Haixia; Simmons, Peter A; Vehige, Joseph G; Chen, Wei
2015-11-01
To evaluate effects of a novel multi-ingredient artificial tear formulation containing carboxymethylcellulose (CMC) and hyaluronic acid (HA) in a murine dry eye model. Dry eye was induced in mice (C57BL/6) using an intelligently controlled environmental system (ICES). CMC+HA (Optive Fusion™), CMC-only (Refresh Tears(®)), and HA-only (Hycosan(®)) artificial tears and control phosphate-buffered saline (PBS) were administered 4 times daily and compared with no treatment (n = 64 eyes per group). During regimen 1 (prevention regimen), mice were administered artificial tears or PBS for 14 days (starting day 0) while they were exposed to ICES, and assessed on days 0 and 14. During regimen 2 (treatment regimen), mice exposed to ICES for 14 days with no intervention were administered artificial tears or PBS for 14 days (starting day 14) while continuing exposure to ICES, and assessed on days 0, 14, and 28. Corneal fluorescein staining and conjunctival goblet cell density were measured. Artificial tear-treated mice had significantly better outcomes than control groups on corneal staining and goblet cell density (P < 0.01). Mice administered CMC+HA also showed significantly lower corneal fluorescein staining and higher goblet cell density, compared with CMC (P < 0.01) and HA (P < 0.05) in both regimens 1 and 2. The artificial tear formulation containing CMC and HA was effective in preventing and treating environmentally induced dry eye. Improvements observed for corneal fluorescein staining and conjunctival goblet cell retention suggest that this combination may be a viable treatment option for dry eye disease.
Marcet, Marcus M; Shtein, Roni M; Bradley, Elizabeth A; Deng, Sophie X; Meyer, Dale R; Bilyk, Jurij R; Yen, Michael T; Lee, W Barry; Mawn, Louise A
2015-08-01
To review the published literature assessing the efficacy and safety of lacrimal drainage system plug insertion for dry eye in adults. Literature searches of the PubMed and Cochrane Library databases were last conducted on March 9, 2015, without date restrictions and were limited to English language abstracts. The searches retrieved 309 unique citations. The primary authors reviewed the titles and abstracts. Inclusion criteria specified reports that provided original data on plugs for the treatment of dry eyes in at least 25 patients. Fifty-three studies of potential relevance were assigned to full-text review. The 27 studies that met the inclusion criteria underwent data abstraction by the panels. Abstracted data included study characteristics, patient characteristics, plug type, insertion technique, treatment response, and safety information. All studies were observational and rated by a methodologist as level II or III evidence. The plugs included punctal, intracanalicular, and dissolving types. Fifteen studies reported metrics of improvement in dry eye symptoms, ocular-surface status, artificial tear use, contact lens comfort, and tear break-up time. Twenty-five studies included safety data. Plug placement resulted in ≥50% improvement of symptoms, improvement in ocular-surface health, reduction in artificial tear use, and improved contact lens comfort in patients with dry eye. Serious complications from plugs were infrequent. Plug loss was the most commonly reported problem with punctal plugs, occurring on average in 40% of patients. Overall, among all plug types, approximately 9% of patients experienced epiphora and 10% required removal because of irritation from the plugs. Canaliculitis was the most commonly reported problem for intracanalicular plugs and occurred in approximately 8% of patients. Other complications were reported in less than 4% of patients on average and included tearing, discomfort, pyogenic granuloma, and dacryocystitis. On the basis of level II and III evidence in these studies, plugs improve the signs and symptoms of moderate dry eye that are not improved with topical lubrication, and they are well tolerated. There are no level I studies that describe the efficacy or safety of lacrimal drainage system plugs. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Tear Film Osmolarity in Subjects with Acute Allergic Rhinoconjunctivitis.
Nitoda, Eirini; Lavaris, Anastasios; Laios, Konstantinos; Androudi, Sophia; Kalogeropoulos, Chris D; Tsatsos, Michael; Damaskos, Christos; Garmpis, Nikolaos; Moschos, Marilita M
2018-01-01
Acute allergic rhinoconjuctivitis is the most common form of ocular allergies. The pathogenetic mechanisms are based on an immunoglobulin E (IgE)-mediated hypersensitivity reaction. On the other hand, tear osmolarity has been suggested to be an index of ocular surface damage and inflammation. These data were the motive to investigate the levels of tear osmolarity in subjects with acute allergic rhinoconjuctivitis, before and after administration of artificial tears. Forty-five subjects with acute allergic rhinoconjuctivitis were randomly divided into three groups, based on the type of artificial tears that they received: Group A (Thera tears), Group B (Wet therapy) and Group C (Tears Naturale free). The eye drops were administered six times a day for 60 days and all subjects underwent grading of subjective symptoms and clinical examination at baseline and at the end of the treatment. The diagnosis of severe eye disease, which was based on ocular surface disease index (OSDI; Allergan, Inc, Irvine, CA, USA) and tear osmolarity values, concerned all patients at baseline. Although the administration of artificial tears significantly ameliorated the symptoms and the ocular variables in all groups, the results were better in the first group. Tear osmolarity was strongly and negatively correlated with tear film breakup time (BUT) and Schirmer I test at 2 months. Contrariwise, symptoms were eliminated, when tear osmolarity was decreased. Acute allergic rhinoconjuctivitis is characterized by tear hyperosmolarity, which can be rehabilitated with the administration of hypotonic artificial tears. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Pflugfelder, Stephen C; De Paiva, Cintia S; Villarreal, Arturo L; Stern, Michael E
2008-01-01
To evaluate the effects of sequential treatment with artificial tears and cyclosporine emulsion on conjunctival goblet cell density and production of transforming growth factor (TGF)-beta2 in patients with dry eye disease. Patients with dry eye disease (N = 6) defined by an Ocular Surface Disease Index symptom score >or=25, Schirmer test 1 <10 mm, and corneal fluorescein and conjunctival lissamine green staining scores >or=3 were treated with artificial tears (Refresh Plus; Allergan, Irvine, CA) 4 times a day for 4 weeks, followed by 0.05% cyclosporine emulsion (Restasis; Allergan) twice a day for 12 weeks. Impression cytology was performed on the bulbar conjunctiva of both eyes at baseline, after artificial tear therapy, and after 6 and 12 weeks of cyclosporine therapy. Goblet cells were counted in 5 representative microscopic fields per membrane in those taken from the temporal and inferior bulbar conjunctiva of the worse eye, and membranes taken from the fellow eye were immunostained for TGF-beta2. There were no differences in mean goblet cell density between baseline and 4 weeks of artificial tears in the temporal and inferior bulbar specimens. After 6 weeks of cyclosporine emulsion, goblet cell density was significantly greater than baseline and artificial tears in the inferior bulbar conjunctiva (P < 0.01). After 12 weeks of cyclosporine emulsion, goblet cell density was significantly greater than baseline and artificial tears in both temporal and inferior bulbar sites (P < 0.01). The number of TGF-beta2-positive goblet cells was also noted to increase after 6 and 12 weeks of cyclosporine therapy (P < 0.001). Cyclosporine emulsion, but not artificial tears, increases goblet cell density and production of the immunoregulatory factor TGF-beta2 in the bulbar conjunctiva in patients with dry eye.
Determination of phosphate concentration and pH in artificial tear drops.
de Frutos-Lezaun, M; Martínez-Soroa, I; Ostra Beldarrain, M; Egia Zurutuza, A; Irastorza Larburu, M B; Fernandez Iriarte, A; Bachiller Cacho, M P
2016-08-01
To determine phosphate concentration and pH in artificial tear eye drops commercially available in Spain. A total of 71 examples of artificial tear preparations were identified in a search of Vademecum 2014 and the Spanish Medicines Agency website. In the 24 artificial tear products containing phosphates, quantification of these was performed by ultraviolet molecular absorption spectrophotometry, and the determination of pH was performed using scan image analysis algorithms of pH strips. Of the 71 artificial tears tested, 24 contained phosphate among their excipients in the data sheet, three of which had a concentration level below detection limit (<0.1mM). The mean phosphate concentration was 17.91±23.87mM. The artificial tear sample containing a higher concentration was Colircusi Humectante (87.1mM). Lubricants based on hypromellose showed the highest phosphate concentration (41.59±32.1mM), showing statistically significant differences compared to povidone (P=.0196) and hyaluronate (P=.0067). Statistically significant differences were found between products containing preservatives (32.39±20.91mM), and preservative free ones (8.49±11.98mM) (P=.0498). However, no difference was found between multidose (20.21±26.91mM) and unidose (9.31±14.39mM) samples, or between brand name (15.44±23.3mM) and generic eye drops (20.81mM). The mean pH was 6.93±0.26 (6.2-7.22). No statistical correlation was detected between phosphate concentration and pH (Spearman's Rho -0.1089 and P=.6125). A total of 24 (33.8%) of the 71 artificial tears contained phosphate. We believe identifying the phosphate concentration of artificial tears is useful information in order to avoid complications in high-risk patients. Copyright © 2016. Published by Elsevier España, S.L.U.
Göbbels, M; Gross, D
1996-01-01
In this controlled, randomized, double-masked study the effect of dexpanthenol-containing artificial tears (Siccaprotect) on patients with dry eyes was examined. 50 patients applied either dexpanthenol-containing artificial tears (Siccaprotect) or the identical, but free of dexpanthenol, eye drops five times daily into the conjunctival sac. No other ophthalmics were administered. The corneal epithelial permeability was measured by fluorophotometry and Schirmer-Test, Rose Bengal staining, tear film break-up time and the patients' subjective complaints were determined before and after 6 weeks of treatment. The dexpanthenol-containing artificial tears (Siccaprotect) improved disturbances of the corneal epithelial permeability significantly in comparison to the dexpanthenol-free eyes drops. The other parameters didn't show relevant differences. These data suggest that, in dry eyes, treatment with dexpanthenol-containing eye drops leads to a favorable and comparing with dexpanthenol-free eye drops superior improvement in disturbances of corneal epithelium permeability.
Superficial Punctate Keratitis
... A viral infection A bacterial infection (including trachoma ) Dry eyes Strong chemicals splashed in the eye Exposure to ... lenses is temporarily discontinued. When the cause is dry eyes, ointments and artificial tears are effective. Artificial tears ...
Goldmann tonometry tear film error and partial correction with a shaped applanation surface.
McCafferty, Sean J; Enikov, Eniko T; Schwiegerling, Jim; Ashley, Sean M
2018-01-01
The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used as corneas were lathed over the apical 3.06 mm diameter to simulate full applanation contact with the prism surface for both GAT and CATS prisms. Tear film separation measurements were completed with both an artificial tear and fluorescein solutions as a fluid bridge. The applanation mire thicknesses were measured and correlated with the tear film separation measurements. Human cadaver eyes were used to validate simulated cornea tear film separation measurement differences between the GAT and CATS prisms. The CATS prism tear film adhesion error (2.74±0.21 mmHg) was significantly less than the GAT prism (4.57±0.18 mmHg, p <0.001). Tear film adhesion error was independent of applanation mire thickness ( R 2 =0.09, p =0.04). Fluorescein produces more tear film error than artificial tears (+0.51±0.04 mmHg; p <0.001). Cadaver eye validation indicated the CATS prism's tear film adhesion error (1.40±0.51 mmHg) was significantly less than that of the GAT prism (3.30±0.38 mmHg; p =0.002). Measured GAT tear film adhesion error is more than previously predicted. A CATS prism significantly reduced tear film adhesion error bŷ41%. Fluorescein solution increases the tear film adhesion compared to artificial tears, while mire thickness has a negligible effect.
Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin
2018-01-01
To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.
New Eye Cleansing Product Improves Makeup-Related Ocular Problems.
Okura, Masako; Kawashima, Motoko; Katagiri, Mikiyuki; Shirasawa, Takuji; Tsubota, Kazuo
2015-01-01
Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.
New Eye Cleansing Product Improves Makeup-Related Ocular Problems
Okura, Masako; Kawashima, Motoko
2015-01-01
Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms. PMID:26347812
Posterior root tear of the medial and lateral meniscus.
Petersen, Wolf; Forkel, Philipp; Feucht, Matthias J; Zantop, Thore; Imhoff, Andreas B; Brucker, Peter U
2014-02-01
An avulsion of the tibial insertion of the meniscus or a radial tear close to the meniscal insertion is defined as a root tear. In clinical practice, the incidence of these lesions is often underestimated. However, several biomechanical studies have shown that the effect of a root tear is comparable to a total meniscectomy. Clinical studies documented progredient arthritic changes following root tears, thereby supporting basic science studies. The clinical diagnosis is limited by unspecific symptoms. In addition to the diagnostic arthroscopy, MRI is considered to be the gold standard of diagnosis of a meniscal root tear. Three different direct MRI signs for the diagnosis of a meniscus root tear have been described: Radial linear defect in the axial plane, vertical linear defect (truncation sign) in the coronal plane, and the so-called ghost meniscus sign in the sagittal plane. Meniscal extrusion is also considered to be an indirect sign of a root tear, but is less common in lateral root tears. During arthroscopy, the function of the meniscus root must be assessed by probing. However, visualization of the meniscal insertions is challenging. Refixation of the meniscal root can be performed using a transtibial pull-out suture, suture anchors, or side-to-side repair. Several short-term studies reported good clinical results after medial or lateral root repair. Nevertheless, MRI and second-look arthroscopy revealed high rates of incomplete or absent healing, especially for medial root tears. To date, most studies are case series with short-term follow-up and level IV evidence. Outerbridge grade 3 or 4 chondral lesions and varus malalignment of >5° were found to predict an inferior clinical outcome after medial meniscus root repair. Further research is needed to evaluate long-term results and to define evident criteria for meniscal root repair.
Posterior medial meniscus root ligament lesions: MRI classification and associated findings.
Choi, Ja-Young; Chang, Eric Y; Cunha, Guilherme M; Tafur, Monica; Statum, Sheronda; Chung, Christine B
2014-12-01
The purposes of this study were to determine the prevalence of altered MRI appearances of "posterior medial meniscus root ligament (PMMRL)" lesions, introduce a classification of lesion types, and report associated findings. We retrospectively reviewed 419 knee MRI studies to identify the presence of PMMRL lesions. Classification was established on the basis of lesions encountered. The medial compartment was assessed for medial meniscal tears in the meniscus proper, medial meniscal extrusion, insertional PMMRL osseous changes, regional synovitis, osteoarthritis, insufficiency fracture, and cruciate ligament abnormality. PMMRL abnormalities occurred in 28.6% (120/419) of the studies: degeneration, 14.3% (60/419) and tear, 14.3% (60/419). Our classification system included degeneration and tearing. Tearing was categorized as partial or complete with delineation of the point of failure as entheseal, midsubstance, or junction to meniscus. Of all tears, 93.3% (56/60) occurred at the meniscal junction. Univariate analysis revealed significant differences between the knees with and without PMMRL lesions in age, medial meniscal tear, medial meniscal extrusion, insertional PMMRL osseous change, regional synovitis, osteoarthritis, insufficiency fracture (p=0.017), and cruciate ligament degeneration (p<0.001). PMMRL lesions are commonly detected in symptomatic patients. We have introduced an MRI classification system. PMMRL lesions are significantly associated with age, medial meniscal tears, medial meniscal extrusion, insertional PMMRL osseous change, regional synovitis, osteoarthritis, insufficiency fracture, and cruciate ligament degeneration.
Biswas, N R; Nainiwal, S K; Das, G K; Langan, U; Dadeya, S C; Mongre, P K; Ravi, A K; Baidya, P
2003-03-01
A comparative randomised double masked multicentric clinical trial has been conducted to find out the efficacy and safety of a herbal eye drop preparation, itone eye drops with artificial tear and placebo in 120 patients with computer vision syndrome. Patients using computer for at least 2 hours continuosly per day having symptoms of irritation, foreign body sensation, watering, redness, headache, eyeache and signs of conjunctival congestion, mucous/debris, corneal filaments, corneal staining or lacrimal lake were included in this study. Every patient was instructed to put two drops of either herbal drugs or placebo or artificial tear in the eyes regularly four times for 6 weeks. Objective and subjective findings were recorded at bi-weekly intervals up to six weeks. Side-effects, if any, were also noted. In computer vision syndrome the herbal eye drop preparation was found significantly better than artificial tear (p < 0.01). No side-effects were noted by any of the drugs. Both subjective and objective improvements were observed in itone treated cases. So, itone can be considered as a useful drug in computer vision syndrome.
Çakır, B; Doğan, E; Çelik, E; Babashli, T; Uçak, T; Alagöz, G
2018-05-01
To investigate the effects of artificial tear treatment on central corneal epithelial thickness, and central, mid-peripheral and peripheral corneal thicknesses in patients with dry eye disease (DED). Patients with DED underwent ocular examinations, including Schirmer-2 test, slit lamp examination for tear break-up time (BUT), corneal topography (CT) for measuring mean central, mid-peripheral and peripheral corneal thickness values and anterior segment optic coherence tomography (AS-OCT) for obtaining central corneal epithelial thickness. After artificial tear treatment (carboxymethylcellulose and sodium hyaluronate formulations) for one month, patients were examined again at a second visit and the results were compared. Sixty-one eyes of 33 female dry eye patients (mean age: 38.3±5.7 years) were enrolled. The mean follow-up time was 36.4±3.3 days. The mean tear BUT and Schirmer-1 tests revealed significant improvement after treatment (P=0.000, P=0.000, respectively). Central corneal epithelium and mean mid-peripheral corneal thicknesses measured significantly higher after treatment (P=0.001, P=0.02). Changes in central and peripheral corneal thicknesses were not statistically significant. Artificial tear treatment in dry eye patients seems to increase central corneal epithelial and mid-peripheral corneal thicknesses. Measurement of corneal epithelial thickness can be a useful tool for evaluation of treatment response in dry eye patients. Further long-term prospective studies are needed to investigate this item. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Artificially modified collagen fibril orientation affects leather tear strength.
Kelly, Susyn J; Wells, Hannah C; Sizeland, Katie H; Kirby, Nigel; Edmonds, Richard L; Ryan, Tim; Hawley, Adrian; Mudie, Stephen; Haverkamp, Richard G
2018-07-01
Ovine leather has around half the tear strength of bovine leather and is therefore not suitable for high-value applications such as shoes. Tear strength has been correlated with the natural collagen fibril alignment (orientation index, OI). It is hypothesized that it could be possible to artificially increase the OI of the collagen fibrils and that an artificial increase in OI could increase tear strength. Ovine skins, after pickling and bating, were strained biaxially during chrome tanning. The strain ranged from 2 to 15% of the initial sample length, either uniformly in both directions by 10% or with 3% in one direction and 15% in the other. Once tanned, the leather tear strengths were measured and the collagen fibril orientation was measured using synchrotron-based small-angle X-ray scattering. The OI increased as a result of strain during tanning from 0.48 to 0.79 (P = 0.001) measured edge-on and the thickness-normalized tear strength increased from 27 to 43 N mm -1 (P < 0.001) after leather was strained 10% in two orthogonal directions. This is evidence to support a causal relationship between high OI (measured edge-on), highly influenced by thickness, and tear strength. It also provides a method to produce stronger leather. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
... techniques are used to repair a rotator cuff tear: During open repair, a surgical incision is made ... repair is done for large or more complex tears. During arthroscopy, the arthroscope is inserted through small ...
Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu
2012-09-01
This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.
An Overview on Dry Eye Treatment: Approaches for Cyclosporin A Delivery
Yavuz, Burçin; Bozdağ Pehlivan, Sibel; Ünlü, Nurşen
2012-01-01
Dry eye syndrome (DES, Keratoconjunctivitis sicca) is a common disorder of the tear film caused by decreased tear production or increased evaporation. Changes in tear composition also promote inflammation on the ocular surface by various mechanisms. Artificial tear drops, tear retention treatment, stimulation of tear secretion, or anti-inflammatory drugs may be used for dry eye treatment according to the severity of the disease. For untreated patients, the risk of ocular infection increases at considerable level and clinical course of the disease may proceed up to infection, corneal ulcer, and blindness. Artificial tears and/or punctual occlusions are used for tear replacement or preservation. New treatment approaches are designed to modify the underlying disease process. For the treatment of severe dry eye disease, cyclosporin A (CsA), the first one of the new generation immunomodulatory drugs, which has an anti-inflammatory effect, is frequently used. CsA has immunosuppressive effects following systemic application. Following local administration of CsA, it is expected to obtain effective drug concentration at the target area and to avoid the various side effects associated with systemic delivery. Microspheres, implants, and liposomes have been developed for administration of CsA subconjunctivally in order to enhance its efficiency. PMID:22619624
Veselovskaya, N N; Zherebko, I B
Conducted a comparative analysis of functional changes in tear production in patients with dry eye syndrome and endocrine ophthalmopathy in the conditions of the long-term acting of preservative free medications based on natural substances. A total of 30 people, aged 35 to 53 years old with clinical manifestations of DES on the background of EO were divided on two groups. In I group eye drops of ectoine and in II - artificial tears were administered. The examination included general and specific methods. The term of follow up - 30 days. It was found that long-term use of preservative free eye drops based on ectoine leads to more expressive positive changes in the condition of the anterior surface of the eye and the secretion and quality of the tear.
[New approaches to the treatment of keratoconjunctivitis sicca].
Safonova, T N; Gladkova, O V; Novikov, I A; Boev, V I; Fedorov, A A
A new method has been developed for the treatment of severe forms of keratoconjunctivitis sicca (KCS) that involves the use of an original cyclosporine A (CyA) saturated soft contact lens (SCL) together with preservative-free artificial tears therapy. to evaluate the effectiveness of the newly developed treatment for KCS based on the use of medical SCL saturated with 0.05% CyA. The patients (43 men, 60 eyes) with severe KCS were divided into 2 groups. Group 1 included 21 patients (30 eyes), who received artificial tears and wore 0.05% CyA-saturated silicone-hydrogel SCLs. Group 2 included 22 patients (30 eyes), who wore unsaturated original SCLs and received CyA instillations 2 times daily and, also, artificial tears. Apart from a standard ophthalmic examination, the assessment included Schirmer's test, Norn's test, vital eye stain tests, tear osmometry, laser confocal tomography of the cornea, optical coherence tomography of the anterior segment with meniscometry, impression cytology of the conjunctiva, tear pH measurement, plating of the content of the conjunctival cavity, measurement of the width of the palpebral fissure, and calculation of the ocular surface disease index. Treatment results were followed up at 1, 3, 6, and 12 months. The use of 0.05% CyA-saturated SCLs allows to halve treatment time for patients with severe KSC (down to 1 week - 1 month) as compared to unsaturated original SCLs in combination with 0.05% CyA instillations and to reduce it 5 times as compared to 0.05% CyA instillations only. The new method of KSC treatment that involves the use of medical SCL of original design (ensures even distribution of 0.05% CyA across the ocular surface) and preservative-free artificial tears has demonstrated high therapeutic effectiveness as compared to existing methods.
Bandlitz, Stefan; Purslow, Christine; Murphy, Paul J; Pult, Heiko
2014-08-26
Using a novel digital meniscometer (PDM), alterations in tear meniscus radius (TMR) were measured simultaneously with blink rate (BR) following the instillation of artificial tears. Central TMR and BR of 22 subjects (11 male and 11 female; mean age, 24.3 ± 2.6 SD years) were measured at baseline, and 0, 1, 5, 10, and 30 minutes after instillation of an artificial tear containing hydroxypropyl-guar and glycol (SYS) or saline (SAL). A dose of 35 μL was applied in one eye in a randomized order with a washout period between each drop. For SAL, compared to baseline TMR (0.33 ± 0.08 mm), TMR significantly increased with drop instillation (1.55 ± 0.69 mm) and at 1 minute (0.66 ± 0.36 mm; P < 0.05), but returned to baseline after 5 minutes. For SYS, TMR (0.32 ± 0.07 mm) remained significantly increased after application (1.62 ± 0.81 mm), and at 1 minute (0.81 ± 0.43 mm) and 5 minutes (0.39 ± 0.08 mm; P < 0.05). Compared to baseline BR with SAL (14.8 ± 7.7) and SYS (14.9 ± 9.4), values were significantly increased upon drop instillation (22.5 ± 11.8; 21.3 ± 11.8; P < 0.05), but returned to baseline after 1 minute. Dry eye symptoms were correlated with baseline BR (r = 0.550, P = 0.008). Results indicate that PDM can detect changes in TMR following instillation of artificial tears. Difference in residence time reflects the different viscosity of each drop. An overload with a large drop may result in an initially increased BR. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Asbell, Penny A
2006-11-01
Dry eye syndrome is a highly prevalent, yet largely under diagnosed, condition that can substantially affect quality of life. Left untreated, dry eye is associated with chronic eye pain and increased risk of ocular surface disease. Current demographic changes and lifestyle factors indicate that the dry eye syndrome patient population will increase significantly, ensuring that general practitioners and ophthalmic clinicians alike will experience more patients presenting with dry eye symptoms. Greater public and practitioner awareness of emerging research, technologies, and therapies is crucial to ensuring appropriate interventions to meet specific patient needs and result in clinically favorable outcomes. In August 2005, a team of ocular surface experts convened for a 1-day roundtable session to discuss the latest information on diagnosing and treating dry eye syndrome and real-world issues in artificial tear therapy, including preservative use. The discussion centered on the mild to moderate dry eye patient and critical features of the ideal artificial tear, which are preservative-free formulation, protection from microbial contamination, cost-effective, non-blurring, and easy to use. Products that match this profile have the advantage of being able to benefit the myriad of patients who comprise the dry eye syndrome population. Ocular surface health should always remain a top priority. Preferred Practice Pattern Dry Eye Syndrome Medical Treatment guidelines should be modified to recommend the use of preservative-free formula artificial tear products for all levels of dry eye conditions in consideration of the medical benefit they offer to dry eye syndrome sufferers. The growing prevalence of dry eye syndrome demands increased attention. Further research, enhanced diagnostic tests, increased use of preservative-free artificial tear formulations as first-line therapy, greater patient-practitioner interaction, and patient education are warranted.
... is mostly caused by a deficiency in the tear glands, and a common preservative in many glaucoma ... for relief is the use of lubricating artificial tears, available as over the counter eye drops, to ...
Napoli, Pietro Emanuele; Satta, Giovanni Maria; Coronella, Franco; Fossarello, Maurizio
2014-07-01
To analyze in vivo the dynamic changes induced by different artificial tears (ATs) in the precorneal tear film (PCTF) and lower tear meniscus (LTM) by using spectral-domain (SD) anterior segment optical coherence tomography (OCT). We prospectively examined 42 normal human eyes by using SD-OCT imaging. On the day before OCT imaging, all enrolled subjects were evaluated for abnormalities of ocular surface. All tear film images were obtained before and after instillation of three different types of ATs (mucomimetic, lipid-based, and saline) in five serial scans: immediately (within 30 seconds), at the first, fifth, 10th, and 20th minute. Subjects received a drop of 35 μL in one randomly selected eye. All examinations were conducted in the same conditions of temperature, brightness, humidity, and time of day. Changes in the morphological pattern of both LTM and PCTF were associated with the type of artificial tear instilled on the ocular surface. Similarly, the radius of curvature (rc), the height (h), and the depth (d) showed dynamic variations depending on treatment. Although by the 20th minute, both h and d returned to baseline values in all groups, a significant difference in rc (compared with baseline) was detected for mucomimetic ATs (P = 0.04) and lipid ATs (P = 0.02). Spectral-domain OCT imaging has preliminarily proved to be a noninvasive tool to evaluate, in real time, the different changes induced by ATs instillation. An important stride in understanding the clinical response to various tear substitutes can be achieved by this objective and quantitative approach. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
... used to increase tear production in people with dry eye disease. Cyclosporine is in a class of medications ... Be sure to mention other eye drops for dry eye disease.if you are using artificial tears, instill ...
Isolation of the ocular surface to treat dysfunctional tear syndrome associated with computer use.
Yee, Richard W; Sperling, Harry G; Kattek, Ashballa; Paukert, Martin T; Dawson, Kevin; Garcia, Marcie; Hilsenbeck, Susan
2007-10-01
Dysfunctional tear syndrome (DTS) associated with computer use is characterized by mild irritation, itching, redness, and intermittent tearing after extended staring. It frequently involves foreign body or sandy sensation, blurring of vision, and fatigue, worsening especially at the end of the day. We undertook a study to determine the effectiveness of periocular isolation using microenvironment glasses (MEGS) alone and in combination with artificial tears in alleviating the symptoms and signs of dry eye related to computer use. At the same time, we evaluated the relative ability of a battery of clinical tests for dry eye to distinguish dry eyes from normal eyes in heavy computer users. Forty adult subjects who used computers 3 hours or more per day were divided into dry eye sufferers and controls based on their scores on the Ocular Surface Disease Index (OSDI). Baseline scores were recorded and ocular surface assessments were made. On four subsequent visits, the subjects played a computer game for 30 minutes in a controlled environment, during which one of four treatment conditions were applied, in random order, to each subject: 1) no treatment, 2) artificial tears, 3) MEGS, and 4) artificial tears combined with MEGS. Immediately after each session, subjects were tested on: a subjective comfort questionnaire, tear breakup time (TBUT), fluorescein staining, lissamine green staining, and conjunctival injection. In this study, a significant correlation was found between cumulative lifetime computer use and ocular surface disorder, as measured by the standardized OSDI index. The experimental and control subjects were significantly different (P<0.05) in the meibomian gland assessment and TBUT; they were consistently different in fluorescein and lissamine green staining, but with P>0.05. Isolation of the ocular surface alone produced significant improvements in comfort scores and TBUT and a consistent trend of improvement in fluorescein staining and lissamine green staining. Isolation plus tears produced a significant improvement in lissamine green staining. The subjective comfort inventory and the TBUT test were most effective in distinguishing between the treatments used. Computer users with ocular surface complaints should have a detailed ocular surface examination and, if symptomatic, they can be effectively treated with isolation of the ocular surface, artificial tears therapy, and effective environmental manipulations.
Asiedu, Kofi; Kyei, Samuel; Ayobi, Benedict; Agyemang, Frank Okyere; Ablordeppey, Reynolds Kwame
2016-12-01
This study sought to provide an evidence-based profile of the diagnosis, treatment and knowledge or opinions on dry eye among optometrists and ophthalmologists in Ghana. This was a cross-sectional survey RESULTS: The responses of 162 participants are included in the analysis. The most commonly used test to diagnosed dry eye disease was tear break-up time followed by patient history. The most common symptom doctors heard from dry eye patients were burning sensation followed by foreign body sensation. The most often prescribed first- line treatment for dry eye was aqueous-based artificial tears followed by lipid-based artificial tears. Most practitioners considered meibomian gland dysfunction as the most common cause of dry eye followed by pterygium. The most often used test to guide or gauge therapeutic effect is patient history followed closely by tear break-up time. Most practitioners reported that 10%-20% of all their patients they see in a day are diagnosed of dry eye. This study showed tear break up time was the main test majority of practitioners in Ghana used to diagnose dry eye but patient history was the main test used to gauge therapeutic effect over time. Burning sensation was the commonest symptom practitioners heard from dry eye patients whilst artificial tears was their main and first-line treatment for dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
... may not produce enough tears. This leads to dry eyes. When dry eyes are not treated, infection, inflammation, and scarring of the cornea can occur. You can relieve dry eyes by using eye drops or artificial tears. Common ...
Choi, Nam-Hong; Son, Kyung-Mo; Victoroff, Brian N
2008-09-01
This technical note describes a new arthroscopic technique to repair a tear of posterior root of the medial meniscus. Cartilage at the insertion area of the posterior horn of the medial meniscus (PHMM) was removed using a curved curette inserted through an anteromedial portal. A metal anchor loaded with two FiberWires (Arthrex, Naples, FL) was placed at the insertion area of the PHMM through a high posteromedial portal. A PDS suture was passed the PHMM by curved suture hook through the anteromedial portal. Two limbs of the PDS were then used to pass two limbs of the FiberWire through the meniscus. The same procedure was repeated for the second FiberWire suture. The sutures were tied, achieving secure fixation of the posterior meniscal root at the anatomic insertion.
Antioxidant content and ultraviolet absorption characteristics of human tears.
Choy, Camus Kar Man; Cho, Pauline; Benzie, Iris F F
2011-04-01
Dry eye syndrome is a common age-related disorder, and decreased antioxidant/ultraviolet (UV) radiation protection in tears may be part of the cause. This study aimed to compare the tear antioxidant content and flow rate in young and older adults. The total antioxidant content and UV absorbing properties of various commercially available ophthalmic solutions used to alleviate dry eye symptoms were also examined. Minimally stimulated tears were collected from 120 healthy Chinese adults with no ocular pathology. Two age groups were studied: 19 to 29 years (n = 58) and 50 to 75 years (n = 62). Tear samples from each subject and 13 ophthalmic solutions were analyzed for total antioxidant content (as the Ferric Reducing/Antioxidant Power value). Tear flow rates were estimated from time taken to collect a fixed volume of tear fluid. UV absorbance spectra of pooled fresh reflex tear fluid and the ophthalmic solutions were determined. Results showed that the antioxidant content of minimally stimulated tears from older subjects (398 ± 160 μmol/l) was not significantly lower than that of younger subjects (348 ± 159 μmol/l; p = 0.0915). However, there was a significant difference in the tear flow rates between the two groups (p < 0.0001), with the younger group having three to four fold higher flow rate. None of the commercial preparations tested had detectable antioxidant content, and none showed the UV absorption characteristics of natural reflex tears. The effect of low flow rate on the dynamic antioxidant supply to the corneal surface indicates that older subjects have poorer overall defense against photooxidative and other oxidative processes. This could predispose older persons to corneal stress and development of dry eye syndrome. The commercially available artificial tears tested lack both the antioxidant content and UV absorbing characteristics of natural tears. Artificial tears formulations that help restore natural antioxidant and UV absorbing properties to the tear film of the aging eye may help prevent or improve dry eye symptoms and promote ocular health.
Glaucoma drops control intraocular pressure and protect optic nerves in a rat model of glaucoma.
Morrison, J C; Nylander, K B; Lauer, A K; Cepurna, W O; Johnson, E
1998-03-01
To determine whether chronic topical glaucoma therapy can control intraocular pressure (IOP) and protect nerve fibers in a rat model of pressure-induced optic nerve damage. Sixteen adult Brown Norway rats were-administered unilateral episcleral vein injections of hypertonic saline to produce scarring of the aqueous humor outflow pathways. Twice daily applications of either artificial tears (n = 6), 0.5% betaxolol (n = 5), or 0.5% apraclonidine (n = 5) were delivered to both eyes, and awake pressures were monitored with a TonoPen XL tonometer for 17 days before the rats were killed. For animals administered artificial tears, the mean IOP of the experimental eyes was 39 +/- 2 mm Hg compared with 29 +/- 1 mm Hg for the control eyes. This difference was statistically significant (P < 0.001). Mean IOPs in the experimental eyes of animals administered betaxolol and apraclonidine were 29 +/- 7 and 29 +/- 4 mm Hg, respectively, whereas the mean IOP in the control eyes was 28 +/- 1 mm Hg for both groups. There was no statistically significant difference among these values. The mean IOP for the experimental eyes in the betaxolol and apraclonidine groups was lower than that in animals administered artificial tears (P = 0.003). Quantitative histologic analysis of optic nerve damage in experimental eyes showed that four of the six animals administered artificial tears had damage involving 100% of the neural area. This degree of damage appeared in only 3 of 10 animals administered glaucoma therapy. Optic nerve protection was closely correlated with IOP history because damage was limited to less than 10% of the cross-sectional area in all animals in which the maximal IOP was less than or equal to 39 mm Hg, more than 2 SD below the mean value for eyes administered artificial tears. Topical glaucoma therapy in this model can prevent IOP elevation and protect optic nerve fibers.
[Abnormal of tear lipid layer and recent advances in clinical study of dry eye].
Xiao, Xin-Ye; Liu, Zu-Guo
2012-03-01
Dry eye is a common disease in the ophthalmological clinic, which is related to the dysfunction of tear film. The tear film is composed of lipid layer, aqueous layer and mucin layer (or lipid layer, aqueous/mucin layer). The lipid of the outmost layer derived from Meibomian gland and distributed on the tear film after blinking can decrease the evaporation and stabilize the tear film. The thickness, quality, and distribution of lipid layer are impaired in many dry eye patients, hence restoring the physiological function of lipid layer may be crucial for the treatment of this kind of dry eye. The lipid artificial tears manifest great effects on increasing lipid layer thickness, stabilizing tear film, improving Meibomian gland dysfunction, and promoting tear film distribution.
Guerini, H; Fermand, M; Godefroy, D; Feydy, A; Chevrot, A; Morvan, G; Gault, N; Drapé, J L
2012-02-01
The supraspinatus tendon is composed of 5 different layers consisting of intertwining bundles. On a front portion of the tendon, the layers become coated bundles which insert on the trochanter. At the insertion, the superficial or bursal surface of the tendon corresponding to the tendon fibers in contact with the subacromial bursa can be distinguished from the deep surface corresponding to the fibers in contact with the glenohumeral joint. A tendon tear may involve partial or total disruption of the tendon fibers and is called full-thickness tear if it affects the entire tendon, and partial-thickness tear if it involves only part of the tendon. Partial-thickness tears of the supraspinatus tendon include lesions of the superficial, deep and central surface or tendon delamination.A contrast enhanced examination requires injection of contrast agent into the joint (arthrography followed by computed tomography (CT) or magnetic resonance imaging (MRI)) to study the deep surface, and injection into the subacromial bursa (bursography followed by CT) to study the superficial surface. MRI and ultrasound (US) examination allow the study of these different tendon layers without the use of contrast agent (which is not possible at CT).
Shi, Jing-lin; Miao, Wan-hong
2012-09-01
With the understanding of the immune inflammatory response in the pathogenesis of dry eyes, and the limitations of widely used artificial tears and numerous pharmaceuticals and methods to promote tear secretion, clinicians pay more attention to the therapies that can promote tear secretion actively. Acupuncture treatment for dry eye may meet this requirement. To observe the clinical efficacy of acupuncture treatment on dry eye and the effects on duration, and to examine the mechanisms of acupuncture in treating patients with dye eyes. The study was performed at Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine from August 2010 to May 2011. Patients with the primary diagnosis of dry eye were enrolled. Sixty-five patients were randomly divided into treatment group and control group, and were given 3 weeks of acupuncture treatment or artificial tear therapy respectively. The enzyme-linked immunosorbent assay was used to detect the lactoferrin content of the tears before and after treatment. In order to evaluate the efficacy of the treatment methods, the Schirmer I test and break-up time were also measured. Compared with before treatment, the lactoferrin content in the tears of patients in the treatment group increased, break-up time was prolonged and the result of the Schirmer I test showed improvement after 3 weeks of treatment. The indexes mentioned above did not change in the control group after treatment. There were no significant differences in tear lactoferrin and Schirmer I test between one week after treatment and after 3-week treatment in the treatment group, but break-up time was significantly shortened. The result of Schirmer I test in the treatment group was significantly higher than that in the control group one week after treatment. Acupuncture can increase tear lactoferrin level, extend tear film break-up time and promote tear secretion in patients with dry eye in a time-limited trial. With the end of treatment, the effect decreased.
Artificial Ligaments: Promise or Panacea?
ERIC Educational Resources Information Center
Lubell, Adele
1987-01-01
The Food and Drug Administration has approved a prosthetic ligament for limited use in persons with damaged anterior cruciate ligaments (ACL). This article addresses ligament repair, ACL tears, current treatment, development of the Gore-Tex artificial ligament, other artificial ligaments in process, and arguments for and against their use.…
Said, Azza Mohamed Ahmed; Farag, Mona Elsayed; Abdulla, Tarek Mohamed; Ziko, Othman Ali Othman; Osman, Wesam Mohamed
2016-01-01
AIM To evaluate the effect of punctal occlusion using thermosensitive (smart plug) versus silicone plug for management of aqueous deficient dry eye on corneal sensitivity, ocular surface health and tear film stability. METHODS A comparative prospective interventional case study included 45 patients with bilateral severe form of aqueous deficient dry eye. In each patient, the smart plug was inserted in the lower punctum of the right eye which was considered as study group 1 and silicone plug was inserted in the lower punctum of the left eye of the same patient which was considered as study group 2. All patients were subjected to careful history taking and questionnaire for subjective assessment of severity of symptoms. Corneal sensitivity, corneal fluorescein, rose bengal staining, Schirmer's I test, tear film break up time and conjunctival impression cytology were performed pre and 1, 3 and 6mo post plug insertion. RESULTS A statistically significant improvement in subjective and objective manifestations occurred following treatment with both types of plugs (P<0.01). The thermosensitive plug caused significant overall improvement, decrease in frequency of application of tear substitutes and improvement of conjunctival impression cytology parameters in the inserted side (P<0.01). Canaliculitis was reported in two eyes (4.4%) following punctal occlusion using thermosensitive plug (study group 1). Spontaneous plug loss occurred in 21 eyes (46.6%) in the silicone plug group (study group 2). CONCLUSION Improvement of subjective and objective manifestations of aqueous deficient dry eye occurs following punctal plug occlusion. Thermosensitive plug has good patient's compliance with fewer complications and lower rates of loss compared to the silicone plug. PMID:27990362
Ruch, David S; Watters, Tyler Steven; Wartinbee, Daniel A; Richard, Marc J; Leversedge, Fraser J; Mithani, Suhail K
2014-08-01
To describe pertinent anatomic findings during repair of chronic, partial distal biceps tendon tears and to compare the complications of surgery with a similar cohort of acute, complete tears. Group 1 included 14 patients (15 elbows) with partial tears managed operatively an average of 10 months from onset of injury or symptoms. Group 2 included a matched cohort of 16 patients (17 elbows) treated for complete, acute tears an average of 19 days from injury. A retrospective review of all 30 patients focused on demographic data, intraoperative findings, and postoperative complications. A single, anterior incision was used in all cases with multiple suture anchors or a bicortical toggling button for fixation of the repair. We evaluated 27 men and 3 women with an average age of 55 years (group 1) and 48 years (group 2). Intratendinous ganglion formation at the site of rupture of the degenerative tendon was observed in 5 cases of partial tears and none of the complete tears. Partial tears involved the lateral aspect or short head of the biceps tendon insertion in all cases. Postoperative complications included lateral antebrachial cutaneous nerve neuritis in 8 group 1 patients and 6 group 2 patients and transient posterior interosseus nerve palsy in 3 group 1 patients. Partial distal biceps tendon ruptures showed a consistent pattern of pathology involving disruption of the lateral side of the tendon insertion involving the small head of the biceps. Degenerative intratendinous ganglion formation was present in one third of cases. Repair of chronic, partial distal biceps tendon injuries may have a higher incidence of posterior interosseous and lateral antebrachial cutaneous nerve palsies. Therapeutic III. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Wei, Xiaojia Eric; Korth, John; Brown, Simon H J; Mitchell, Todd W; Truscott, Roger J W; Blanksby, Stephen J; Willcox, Mark D P; Zhao, Zhenjun
2013-12-09
To establish a simple and rapid analytical method, based on direct insertion/electron ionization-mass spectrometry (DI/EI-MS), for measuring free cholesterol in tears from humans and rabbits. A stable-isotope dilution protocol employing DI/EI-MS in selected ion monitoring mode was developed and validated. It was used to quantify the free cholesterol content in human and rabbit tear extracts. Tears were collected from adult humans (n = 15) and rabbits (n = 10) and lipids extracted. Screening, full-scan (m/z 40-600) DI/EI-MS analysis of crude tear extracts showed that diagnostic ions located in the mass range m/z 350 to 400 were those derived from free cholesterol, with no contribution from cholesterol esters. DI/EI-MS data acquired using selected ion monitoring (SIM) were analyzed for the abundance ratios of diagnostic ions with their stable isotope-labeled analogues arising from the D6-cholesterol internal standard. Standard curves of good linearity were produced and an on-probe limit of detection of 3 ng (at 3:1 signal to noise) and limit of quantification of 8 ng (at 10:1 signal to noise). The concentration of free cholesterol in human tears was 15 ± 6 μg/g, which was higher than in rabbit tears (10 ± 5 μg/g). A stable-isotope dilution DI/EI-SIM method for free cholesterol quantification without prior chromatographic separation was established. Using this method demonstrated that humans have higher free cholesterol levels in their tears than rabbits. This is in agreement with previous reports. This paper provides a rapid and reliable method to measure free cholesterol in small-volume clinical samples.
Lee, Jong-Hyuck; Kim, Jae Hyuck; Kim, Sun Woong
2017-02-27
To compare the repeatability of central corneal thickness (CCT) measurement using the Pentacam between dry eyes and healthy eyes, as well as to investigate the effect of artificial tears on CCT measurement. The corneal thicknesses of 34 patients with dry eye and 28 healthy subjects were measured using the Pentacam. One eye from each subject was assigned randomly to a repeatability test, wherein a single operator performed three successive CCT measurements time points-before and 5 min after instillation of one artificial teardrop. The repeatability of measurements was assessed using the coefficient of repeatability and the intraclass correlation coefficient. The coefficient of repeatability values of the CCT measurements in dry and healthy eyes were 24.36 and 10.69 μm before instillation, and 16.85 and 9.72 μm after instillation, respectively. The intraclass correlation coefficient was higher in healthy eyes than that of in dry eyes (0.987 vs. 0.891), and it had improved significantly in dry eyes (0.948) after instillation of one artificial teardrop. The CCT measurement fluctuated in dry eyes (repeated-measures analysis of variance, P<0.001), whereas no significant changes were detected in healthy eyes, either before or after artificial tear instillation. Central corneal thickness measurement is less repeatable in dry eyes than in healthy eyes. Artificial tears improve the repeatability of CCT measurements obtained using the Pentacam in dry eyes.
Metabolomics and Trace Element Analysis of Camel Tear by GC-MS and ICP-MS.
Ahamad, Syed Rizwan; Raish, Mohammad; Yaqoob, Syed Hilal; Khan, Altaf; Shakeel, Faiyaz
2017-06-01
Camel tear metabolomics and elemental analysis are useful in getting the information regarding the components responsible for maintaining the protective system that allows living in the desert and dry regions. The aim of this study was to correlate that the camel tears can be used as artificial tears for the evaluation of dryness in the eye. Eye biomarkers of camel tears were analyzed by gas chromatography-mass spectroscopy (GC-MS) and inductively coupled plasma mass spectroscopy (ICP-MS). The major compounds detected in camel tears by GC-MS were alanine, valine, leucine, norvaline, glycine, cadaverine, urea, ribitol, sugars, and higher fatty acids like octadecanoic acid and hexadecanoic acid. GC-MS analysis of camel tears also finds several products of metabolites and its associated metabolic participants. ICP-MS analysis showed the presence of different concentration of elemental composition in the camel tears.
Favre, Philippe; Loeb, Michael D; Helmy, Naeder; Gerber, Christian
2008-01-01
In patients with pseudoparesis of the shoulder resulting from irreparable rotator cuff tears, reverse shoulder arthroplasty (RSA) can restore active elevation, but external rotation remains less predictable. Latissimus dorsi transfer (LDT) has been shown to be effective in restoring external rotation in patients with posterosuperior tears of the rotator cuff. The aim of this study is to determine the capacity of the LDT to restore external rotation in combination with RSA and to investigate the mechanical advantage produced by 3 different insertion sites. A biomechanical model was created using a reverse total shoulder prosthesis with 3 different transfer insertions. Moment arms were measured for 2 static positions and 1 motion of the humerus. The moment arm analysis showed that LDT can improve active external rotation in the setting of a reverse prosthesis. An insertion site on the posterior side of the greater tuberosity (adjacent to the teres minor insertion) produced a greater external rotation moment arm.
Recent developments on dry eye disease treatment compounds.
Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus
2014-01-01
Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film.
Insert Modifications Improve Access to Artificial Red-Cockaded Woodpecker Next Cavities
John W. Edwards; Ernest E. Stevens; Charles A. Dachelet
1997-01-01
A designfor a modified, artificial Red-cockaded Woodpecker(Picoides borealis) cavity insert is presented. This modification allowed eggs and young to be inspected easily, removed, and replaced throughout the nesting period. Modifications to cavity inserts are best done before installation, but can be easily retrofitted in existing artificial cavities...
In Vitro Spoilation of Silicone-Hydrogel Soft Contact Lenses in a Model-Blink Cell.
Peng, Cheng-Chun; Fajardo, Neil P; Razunguzwa, Trust; Radke, Clayton J
2015-07-01
We developed an in vitro model-blink cell that reproduces the mechanism of in vivo fouling of soft contact lenses. In the model-blink cell, model tear lipid directly contacts the lens surface after forced aqueous rupture, mirroring the pre-lens tear-film breakup during interblink. Soft contact lenses are attached to a Teflon holder and immersed in artificial tear solution with protein, salts, and mucins. Artificial tear-lipid solution is spread over the air/tear interface as a duplex lipid layer. The aqueous tear film is periodically ruptured and reformed by withdrawing and reinjecting tear solution into the cell, mimicking the blink-rupture process. Fouled deposits appear on the lenses after cycling, and their compositions and spatial distributions are subsequently analyzed by optical microscopy, laser ablation electrospray ionization mass spectrometry, and two-photon fluorescence confocal scanning laser microscopy. Discrete deposit (white) spots with an average size of 20 to 300 μm are observed on the studied lenses, confirming what is seen in vivo and validating the in vitro model-blink cell. Targeted lipids (cholesterol) and proteins (albumin from bovine serum) are identified in the discrete surface deposits. Both lipid and protein occur simultaneously in the surface deposits and overlap with the white spots observed by optical microscopy. Additionally, lipid and protein penetrate into the bulk of tested silicone-hydrogel lenses, likely attributed to the bicontinuous microstructure of oleophilic silicone and hydrophilic polymer phases of the lens. In vitro spoilation of soft contact lenses is successfully achieved by the model-blink cell confirming the tear rupture/deposition mechanism of lens fouling. The model-blink cell provides a reliable laboratory tool for screening new antifouling lens materials, surface coatings, and care solutions.
Calvão-Santos, Gil; Borges, Cristina; Nunes, Sandrina; Salgado-Borges, José; Duarte, Lilianne
2011-01-01
To compare the efficacy of 3 different artificial tears (AT) acting primarily in one of the 3 tear film layers (Tears Again®, lipidic; Opticol®, aqueous; Optive®, mucin) in recovering the tear film changes in patients with dry eye symptoms due to external causes. A total of 27 patients, with dry eye symptoms associated with extra hours of computer or contact lenses use, were randomized to 4 treatment groups: A received Tears Again®; B received Optive®; C received Opticol®; D received no treatment (control). Patients were observed in 3 visits: day 0, day 7, and day 30. Tear break-up time (TBUT) and Schirmer tests and the Ocular Surface Disease Index were performed. Data analysis was performed. There were no significant differences between the groups. From day 0 to day 30, there was a decrease in the number of eyes with abnormal TBUT (not significant) and Schirmer (significant in A, B, D; p<0.031). There was an increase in the average TBUT for all groups (significant in A, C; p<0.001) and a decrease in the average Schirmer value in groups B, C, and D (not significant) and an increase in group A (p = 0.002). There was a decrease in the average Ocular Surface Disease Index value in all groups (p<0.045). All AT were efficient at recovering the tear film, but those acting primarily on the internal and intermediate layer led to a mild decline on lachrymal production. An association of different kinds of AT acting on each layer can be the best treatment for corneal surface diseases affecting eye lubrication.
Vardhan, Prabhakar; Dhiman, Kartar Singh
2014-01-01
Dry eye syndrome (DES) is a common ophthalmic problem predominantly affecting middle-aged and elderly people. It is a disease of deficient or deranged tears and ocular surface disorder producing symptoms of discomfort, visual disturbance, and tears film instability. Shushkakshipaka, an etymologically and clinically similar entity to DES, is defined in Ayurveda as the disease affecting all parts of the eye characterized by Paka (inflammation) due to Shuskatva (dryness) caused by altered coherence of Ashru (tears) with ocular surface or due to lack of Ashru. To compare the effect of Keshanjana and Netra Parisheka in Shushkakshipaka with artificial tear drops (carboxy methyl cellulose [CMC]). To search a safe, potent and cost-effective Ayurvedic treatment for DES, a randomized comparative clinical trial was conducted on 32 patients. Patients were divided in two groups 15 in group I and 17 in group II. Group I treated with artificial tear drop four times a day for topical use and group II treated with combination therapy of Keshanjana applied topically once a day and Netra Prisheka was done thrice a day. The effect of Ayurvedic management was found to be equivalent to the standard therapy, although the trial drugs provided more relief in foreign body sensation, burning sensation, dryness, pain, photophobia, itching, crusting, stuck eyelids, tear meniscus, conjunctival congestion, Schirmer I test, and tear film break-up time (TUBT). The standard therapy provided more relief than trial drugs in mucous discharges, transiently blurred vision, redness, and the presence of mucin debris in tear film. Keshanjana and Netra Parisheka can be used as a potent, safe and cost-effective treatment to ameliorate the symptoms of DES.
Vardhan, Prabhakar; Dhiman, Kartar Singh
2014-01-01
Background: Dry eye syndrome (DES) is a common ophthalmic problem predominantly affecting middle-aged and elderly people. It is a disease of deficient or deranged tears and ocular surface disorder producing symptoms of discomfort, visual disturbance, and tears film instability. Shushkakshipaka, an etymologically and clinically similar entity to DES, is defined in Ayurveda as the disease affecting all parts of the eye characterized by Paka (inflammation) due to Shuskatva (dryness) caused by altered coherence of Ashru (tears) with ocular surface or due to lack of Ashru. Aim: To compare the effect of Keshanjana and Netra Parisheka in Shushkakshipaka with artificial tear drops (carboxy methyl cellulose [CMC]). Materials and Methods: To search a safe, potent and cost-effective Ayurvedic treatment for DES, a randomized comparative clinical trial was conducted on 32 patients. Patients were divided in two groups 15 in group I and 17 in group II. Group I treated with artificial tear drop four times a day for topical use and group II treated with combination therapy of Keshanjana applied topically once a day and Netra Prisheka was done thrice a day. Results: The effect of Ayurvedic management was found to be equivalent to the standard therapy, although the trial drugs provided more relief in foreign body sensation, burning sensation, dryness, pain, photophobia, itching, crusting, stuck eyelids, tear meniscus, conjunctival congestion, Schirmer I test, and tear film break-up time (TUBT). The standard therapy provided more relief than trial drugs in mucous discharges, transiently blurred vision, redness, and the presence of mucin debris in tear film. Conclusion: Keshanjana and Netra Parisheka can be used as a potent, safe and cost-effective treatment to ameliorate the symptoms of DES. PMID:26664237
Atsumi, Satoru; Hara, Kunio; Arai, Yuji; Yamada, Manabu; Mizoshiri, Naoki; Kamitani, Aguri; Kubo, Toshikazu
2018-01-01
Abstract Rationale: Considering the risk of osteoarthritis following resection of a horizontally torn meniscus of the knee, repairing and preserving the meniscus as much as possible is preferred. We report 3 cases of restoration of horizontally torn menisci using a novel arthroscopic method we have called “all-inside interleaf vertical suture” that afforded preservation. Patient concerns: The 3 patients (aged 14, 17, and 21 years) had knee pain through sports activity. Diagnoses: All patients had horizontal tears in the posteromedial part of the meniscus. Interventions: The method uses Fast-Fix, whereby a first anchor is inserted from the tibial surface of the tear's superior leaflet and a second anchor is inserted from the femoral surface of the tear's inferior leaflet, and the 2 leaflets are closed using vertical suture. In all cases, the suture knots were embedded between the superior leaflet and inferior leaflet, avoiding contact with the articular cartilage, and superior leaflet and inferior leaflet crimping was good. Outcomes: All 3 were able to resume competing in sport and ≥ 1 year after surgery they had no pain and their postoperative mean Lysholm scores were 99.7. There were no complications or recurrence. On magnetic resonance imaging, the signal intensity of all the horizontal tears was high before surgery but low after surgery, suggesting that the repaired tear was healing. Lessons: The all-inside interleaf vertical suture procedure is a new surgical technique that can repair posteromedial horizontal meniscal tears of the knee of young people by easy crimping of the superior and inferior leaflets without the suture knots causing complications. PMID:29443758
Autologous serum eye drops for dry eye.
Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K
2017-02-28
Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included trials. We contacted investigators to ask for missing data. For both primary and secondary outcomes, we reported mean differences with corresponding 95% confidence intervals (CIs) for continuous outcomes. We did not perform meta-analysis owing to differences in outcome assessments across trials. We identified five eligible RCTs (92 participants) that compared AS versus artificial tears or saline in individuals with dry eye of various origins (Sjögren's syndrome-related dry eye, non-Sjögren's syndrome dry eye, and postoperative dry eye induced by laser-assisted in situ keratomileusis (LASIK)). We assessed the certainty of evidence as low or very low because of lack of reporting of quantitative data for most outcomes and unclear or high risk of bias among trials. We judged most risk of bias domains to have unclear risk in two trials owing to insufficient reporting of trial characteristics, and we considered one trial to have high risk of bias for most domains. We judged the remaining two trials to have low risk of bias; however, these trials used a cross-over design and did not report data in a way that could be used to compare outcomes between treatment groups appropriately. Incomplete outcome reporting and heterogeneity among outcomes and follow-up periods prevented inclusion of these trials in a summary meta-analysis.Three trials compared AS with artificial tears; however, only one trial reported quantitative data for analysis. Low-certainty evidence from one trial suggested that AS might provide some improvement in participant-reported symptoms compared with artificial tears after two weeks of treatment; the mean difference in mean change in symptom score measured on a visual analogue scale (range 0 to 100, with higher scores representing worse symptoms) was -12.0 (95% confidence interval (CI) -20.16 to -3.84; 20 participants). This same trial found mixed results with respect to ocular surface outcomes; the mean difference in mean change in scores between AS and artificial tears was -0.9 (95% CI -1.47 to -0.33; 20 participants; low-certainty evidence) for fluorescein staining and -2.2 (95% CI -2.73 to -1.67; 20 participants; low-certainty evidence) for Rose Bengal staining. Both staining scales range from 0 to 9, with higher scores indicating worse results. The mean change in tear film break-up time was 2.00 seconds longer (95% CI 0.99 to 3.01; 20 participants; low-certainty evidence) in the AS group than in the artificial tears group. Investigators reported no clinically meaningful differences in Schirmer's test scores between groups (mean difference -0.40 mm, 95% CI -2.91 to 2.11; 20 participants; low-certainty evidence). None of these three trials reported tear hyperosmolarity and adverse events.Two trials compared AS versus saline; however, only one trial reported quantitative data for analysis of only one outcome (Rose Bengal staining). Trial investigators of the two studies reported no differences in symptom scores, fluorescein staining scores, tear film break-up times, or Schirmer's test scores between groups at two to four weeks' follow-up. Very low-certainty evidence from one trial suggested that AS might provide some improvement in Rose Bengal staining scores compared with saline after four weeks of treatment; the mean difference in Rose Bengal staining score (range from 0 to 9, with higher scores showing worse results) was -0.60 (95% CI -1.11 to -0.09; 35 participants). Neither trial reported tear hyperosmolarity outcomes. One trial reported adverse events; two of 12 participants had signs of conjunctivitis with negative culture that did resolve. Overall, investigators reported inconsistency in possible benefits of AS for improving participant-reported symptoms and other objective clinical measures. There might be some benefit in symptoms with AS compared with artificial tears in the short-term, but we found no evidence of an effect after two weeks of treatment. Well-planned, large, high-quality RCTs are warranted to examine participants with dry eye of different severities by using standardized questionnaires to measure participant-reported outcomes, as well as objective clinical tests and objective biomarkers to assess the benefit of AS therapy for dry eye.
Recent developments on dry eye disease treatment compounds
Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus
2013-01-01
Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film. PMID:24526854
Sindt, Christine W; Foulks, Gary N
2013-01-01
The aim of the study reported here was to assess the efficacy of an artificial tear emulsion for the treatment of dry eye associated with meibomian gland dysfunction (MGD). At five clinics, patients completed a 1-week treatment with their habitual topical therapy and then a 4-week treatment with open-label study medication: Systane® Balance Lubricant Eye Drops (Alcon, Alcon Inc, Fort Worth, TX, USA). Subjective assessments included a preference survey, the Impact of Dry Eye in Everyday Life questionnaire, and the Work Productivity and Activity Impairment questionnaire. Objective assessments by unmasked investigators included visual acuity, meibomian gland expression and dropout, tear film breakup time, corneal staining, and dosing frequency. At baseline, the 49 patients had mean meibomian gland expression grades and gland dropout that indicated mild to moderate MGD. Patients administered their habitual therapy 2.5 ± 1.3 times per day. After 4 weeks of study medication, the Impact of Dry Eye in Everyday Life questionnaire results indicated statistically and clinically significant improvements. Fewer than half of the participants were employed, limiting the usefulness of the Work Productivity and Activity Impairment questionnaire. Visual acuity remained statistically similar, while corneal staining and tear film breakup time improved significantly (P < 0.05) but modestly. The outcomes were achieved with 1.9 ± 1.1 doses per day of study medication, a significantly lower frequency than the habitual frequency (P < 0.001). The most common medication-related adverse event was blurred vision (3/49 patients, 6.1%). At study conclusion, 27/44 (61.4%) survey respondents preferred the study medication to their habitual therapy. The artificial tear emulsion was effective for treating the signs and symptoms of dry eye in MGD patients.
Ocular Pharmacology of Tear Film, Dry Eye, and Allergic Conjunctivitis.
Gulati, Shilpa; Jain, Sandeep
2017-01-01
Dry Eye Disease (DED) is "a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear-film instability with potential damage to the ocular surface." DED comprises two etiologic categories: aqueous-deficient dry eye (ADDE) and evaporative dry eye (EDE). Diagnostic workup of DED should include clinical history, symptom questionnaire, fluorescein TBUT, ocular surface staining grading, Schirmer I/II, lid and meibomian pathology, meibomian expression, followed by other available tests. New diagnostic tests employ the Oculus Keratograph, which performs non-invasive tear-film analysis and a bulbar redness (BR). The TearLab Osmolarity Test enables rapid clinical evaluation of tear osmolarity. Lipiview is a recently developed diagnostic tool that uses interferometry to quantitatively evaluate tear-film thickness. In DED, epithelial and inflammatory cells produce a variety of inflammatory mediators. A stagnant tear film and decreased concentration of mucin result in the accumulation of inflammatory factors that can penetrate tight junctions and cause epithelial cell death. DED treatment algorithms are based on severity of clinical signs and symptoms, and disease etiology. Therapeutic approaches include lubricating artificial tears and immunomodulatory agents.
Autologous serum eye drops for dry eye
Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K
2017-01-01
Background Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. Objectives We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. Selection criteria We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included trials. We contacted investigators to ask for missing data. For both primary and secondary outcomes, we reported mean differences with corresponding 95% confidence intervals (CIs) for continuous outcomes. We did not perform meta-analysis owing to differences in outcome assessments across trials. Main results We identified five eligible RCTs (92 participants) that compared AS versus artificial tears or saline in individuals with dry eye of various origins (Sjögren’s syndrome-related dry eye, non-Sjögren’s syndrome dry eye, and postoperative dry eye induced by laser-assisted in situ keratomileusis (LASIK)). We assessed the certainty of evidence as low or very low because of lack of reporting of quantitative data for most outcomes and unclear or high risk of bias among trials. We judged most risk of bias domains to have unclear risk in two trials owing to insufficient reporting of trial characteristics, and we considered one trial to have high risk of bias for most domains. We judged the remaining two trials to have low risk of bias; however, these trials used a cross-over design and did not report data in a way that could be used to compare outcomes between treatment groups appropriately. Incomplete outcome reporting and heterogeneity among outcomes and follow-up periods prevented inclusion of these trials in a summary meta-analysis. Three trials compared AS with artificial tears; however, only one trial reported quantitative data for analysis. Low-certainty evidence from one trial suggested that AS might provide some improvement in participant-reported symptoms compared with artificial tears after two weeks of treatment; the mean difference in mean change in symptom score measured on a visual analogue scale (range 0 to 100, with higher scores representing worse symptoms) was −12.0 (95% confidence interval (CI) −20.16 to −3.84; 20 participants). This same trial found mixed results with respect to ocular surface outcomes; the mean difference in mean change in scores between AS and artificial tears was −0.9 (95% CI −1.47 to −0.33; 20 participants; low-certainty evidence) for fluorescein staining and −2.2 (95% CI −2.73 to −1.67; 20 participants; low-certainty evidence) for Rose Bengal staining. Both staining scales range from 0 to 9, with higher scores indicating worse results. The mean change in tear film break-up time was 2.00 seconds longer (95% CI 0.99 to 3.01; 20 participants; low-certainty evidence) in the AS group than in the artificial tears group. Investigators reported no clinically meaningful differences in Schirmer’s test scores between groups (mean difference −0.40 mm, 95% CI −2.91 to 2.11; 20 participants; low-certainty evidence). None of these three trials reported tear hyperosmolarity and adverse events. Two trials compared AS versus saline; however, only one trial reported quantitative data for analysis of only one outcome (Rose Bengal staining). Trial investigators of the two studies reported no differences in symptom scores, fluorescein staining scores, tear film breakup times, or Schirmer’s test scores between groups at two to four weeks’ follow-up. Very low-certainty evidence from one trial suggested that AS might provide some improvement in Rose Bengal staining scores compared with saline after four weeks of treatment; the mean difference in Rose Bengal staining score (range from 0 to 9, with higher scores showing worse results) was −0.60 (95% CI −1.11 to – 0.09; 35 participants). Neither trial reported tear hyperosmolarity outcomes. One trial reported adverse events; two of 12 participants had signs of conjunctivitis with negative culture that did resolve. Authors’ conclusions Overall, investigators reported inconsistency in possible benefits of AS for improving participant-reported symptoms and other objective clinical measures. There might be some benefit in symptoms with AS compared with artificial tears in the short-term, but we found no evidence of an effect after two weeks of treatment. Well-planned, large, high-quality RCTs are warranted to examine participants with dry eye of different severities by using standardized questionnaires to measure participant-reported outcomes, as well as objective clinical tests and objective biomarkers to assess the benefit of AS therapy for dry eye. PMID:28245347
Atzei, A; Luchetti, R; Garagnani, L
2017-05-01
The classical definition of 'Palmer Type IB' triangular fibrocartilage complex tear, includes a spectrum of clinical conditions. This review highlights the clinical and arthroscopic criteria that enable us to categorize five classes on a treatment-oriented classification system of triangular fibrocartilage complex peripheral tears. Class 1 lesions represent isolated tears of the distal triangular fibrocartilage complex without distal radio-ulnar joint instability and are amenable to arthroscopic suture. Class 2 tears include rupture of both the distal triangular fibrocartilage complex and proximal attachments of the triangular fibrocartilage complex to the fovea. Class 3 tears constitute isolated ruptures of the proximal attachment of the triangular fibrocartilage complex to the fovea; they are not visible at radio-carpal arthroscopy. Both Class 2 and Class 3 tears are diagnosed with a positive hook test and are typically associated with distal radio-ulnar joint instability. If required, treatment is through reattachment of the distal radio-ulnar ligament insertions to the fovea. Class 4 lesions are irreparable tears due to the size of the defect or to poor tissue quality and, if required, treatment is through distal radio-ulnar ligament reconstruction with tendon graft. Class 5 tears are associated with distal radio-ulnar joint arthritis and can only be treated with salvage procedures. This subdivision of type IB triangular fibrocartilage complex tear provides more insights in the pathomechanics and treatment strategies. II.
Liu, Qingyu; Liu, Junling; Ren, Chengda; Cai, Wenting; Wei, Qingquan; Song, Yi; Yu, Jing
2017-01-01
The purpose of this study was to investigate whether acupuncture is effective at treating dry eye disease among postmenopausal women and to identify the possible mechanisms. Twenty-eight postmenopausal women with dry eye disease were randomly divided into two groups: an acupuncture plus artificial tears (AC + AT) group and an artificial tears (AT) only group. After baseline examination of clinical parameters and tear sample collection, each patient received the designated modality of topical therapy for 2 months. Post-treatment documentation of clinical parameters was recorded, and tear samples were collected. Tear samples from the AC + AT group were subjected to two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (2D nano-LC-MS/MS). Western blot analysis was also performed on tear samples from both groups. After treatment, the Ocular Surface Disease Index scores, symptom assessment scores, scores of sign assessment, and tear break-up time were significantly improved in both groups ( P =0.000). Symptom assessment scores were significantly improved in the AC + AT group ( P =0.000) compared with the AT group. 2D nano-LC-MS/MS identified 2,411 proteins, among which 142 were downregulated and 169 were upregulated. After combined AC + AT treatment, the abundance of secreted proteins was increased, whereas that of cytoplasmic proteins decreased (Pearson's χ 2 test, P =0.000, P =0.000, respectively). Proteins involved in immunity and regulation were also more abundant (Pearson's χ 2 test, P =0.040, P =0.016, respectively), while components and proliferation-related proteins were downregulated (Pearson's χ 2 test, P =0.003, P =0.011, respectively). AC + AT treatment increased protein synthesis and secretion, and improved clinical symptoms. These results indicate that acupuncture may be a complimentary therapy for treating postmenopausal dry eye disease.
Autologous serum eye drops for dry eye
Pan, Qing; Angelina, Adla; Zambrano, Andrea; Marrone, Michael; Stark, Walter J; Heflin, Thomas; Tang, Li; Akpek, Esen K
2014-01-01
Background Theoretically, autologous serum eye drops (AS) have a potential advantage over traditional therapies based on the assumption that AS serve not only as a lacrimal substitute to provide lubrication, but also contain other biochemical components mimicking natural tears more closely. The application of AS in dry eye treatment has gained popularity as a second-line therapy in the treatment of dry eye. Published studies on the subject indicate that autologous serum could be an effective treatment for dry eye. Objectives To evaluate the efficacy and safety of AS compared to artificial tears for treating dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 3), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLD MEDLINE, (January 1950 to April 2013), EMBASE (January 1980 to April 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to April 2013), the meta Register of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (September 2013) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 15 April 2013. Selection criteria We included randomized controlled trials (RCTs) in which AS was compared to artificial tears in the treatment of dry eye in adults. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text articles of potentially eligible trials. Two review authors extracted data and assessed the methodological quality and characteristics of the included trials.We contacted investigators for missing data. For both primary and secondary outcomes, we reported mean differences with corresponding 95% confidence intervals (CIs) for continuous outcomes. Main results We identified four eligible RCTs in which AS was compared with artificial tear treatment or saline in individuals (n = 72 participants) with dry eye of various etiologies (Sjögren’s syndrome-related dry eye, non-Sjögren’s syndrome dry eye and postoperative dry eye induced by laser-assisted in situ keratomileusis (LASIK)). The quality of the evidence provided by these trials was variable. A majority of the risk of bias domains were judged to have an unclear risk of bias in two trials owing to insufficient reporting of trial characteristics. One trial was considered to have a low risk of bias for most domains while another was considered to have a high risk of bias for most domains. Incomplete outcome reporting and heterogeneity in the participant populations and follow-up periods prevented the inclusion of these trials in a summary meta-analysis. For the primary outcome, improvement in participant-reported symptoms at one month, one trial (12 participants) showed no difference in participant-reported symptoms between 20% AS and artificial tears. Based on the results of two trials in 32 participants, 20% AS may provide some improvement in participant-reported symptoms compared to traditional artificial tears after two weeks of treatment. One trial also showed positive results with a mean difference in tear breakup time (TBUT) of 2.00 seconds (95% CI 0.99 to 3.01 seconds) between 20% AS and artificial tears after two weeks, which were not similar to findings from the other trials. Based on all other objective clinical assessments included in this review, AS was not associated with improvements in aqueous tear production measured by Schirmer’s test (two trials, 33 participants), ocular surface condition with fluorescein (four trials, 72 participants) or Rose Bengal staining (three trials, 60 participants), and epithelial metaplasia by impression cytology compared to artificial tears (one trial, 12 participants). Data on adverse effects were not reported by three of the included studies. In one study, there were no serious adverse events reported with the collection of and treatment with AS. Authors’ conclusions Overall there was inconsistency in the possible benefits of AS in improving participant-reported symptoms and TBUT and lack of effect based on other objective clinical measures. Well-planned, large, high-quality RCTs are warranted, in different severities of dry eye and using standardized questionnaires to measure participant-reported outcomes and objective clinical tests as well as objective biomarkers to assess the benefit of AS therapy for dry eye. PMID:23982997
Heynen, Miriam; Kay, Lise M.M.; Dominici, Claudia Yvette; Khan, Warda; Ng, Wendy W.S.; Jones, Lyndon
2011-01-01
Purpose To characterize various properties of a physiologically-relevant artificial tear solution (ATS) containing a range of tear film components within a complex salt solution, and to measure contact lens parameters and lipid deposition of a variety of contact lens materials after incubation in this ATS. Methods A complex ATS was developed that contains a range of salts, proteins, lipids, mucin, and other tear film constituents in tear-film relevant concentrations. This ATS was tested to confirm that its pH, osmolality, surface tension, and homogeneity are similar to human tears and remain so throughout the material incubation process, for up to 4 weeks. To confirm that silicone hydrogel and conventional hydrogel contact lens materials do not alter in physical characteristics beyond what is allowed by the International Organization for Standardization (ISO) 18369–2. The diameter, center thickness, and calculated base curve were measured for five different lens materials directly out of the blister pack, after a rinse in saline and then following a two week incubation in the modified ATS. To test the ATS and the effect of its composition on lipid deposition, two lens materials were incubated in the ATS and a modified version for several time points. Both ATS solutions contained trace amounts of carbon-14 cholesterol and phosphatidylcholine, such that deposition of these specific lipids could be quantified using standard methods. Results This ATS is a complex mixture that remains stable at physiologically relevant pH (7.3–7.6), osmolality (304–306 mmol/kg), surface tension (40–46 dynes/cm) and homogeneity over an incubation period of three weeks or more. The physical parameters of the lenses tested showed no changes beyond that allowed by the ISO guidelines. Incubations with the ATS found that balafilcon A lenses deposit significantly more cholesterol and phosphatidylcholine than omafilcon A lenses (p<0.05) and that removing lactoferrin and immunoglobulin G from the ATS can significantly decrease the mass of lipid deposited. Conclusions This paper describes a novel complex artificial tear solution specially designed for in-vial incubation of contact lens materials. This solution was stable and did not adversely affect the physical parameters of the soft contact lenses incubated within it and showed that lipid deposition was responsive to changes in ATS composition. PMID:22219635
Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.
2014-01-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness. PMID:25473606
Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D
2014-10-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.
Dry eye disease in French elderly subjects: the Alienor Study.
Malet, Florence; Le Goff, Mélanie; Colin, Joseph; Schweitzer, Cédric; Delyfer, Marie-Noëlle; Korobelnik, Jean-François; Rougier, Marie-Bénédicte; Radeau, Thierry; Dartigues, Jean-François; Delcourt, Cécile
2014-09-01
To describe dry eye disease in French elderly subjects. The Alienor Study is a population-based study on age-related eye disease in 963 residents of Bordeaux (France), aged 73 years or more. Self-reported dry eye disease and use of artificial tears were documented through face-to-face interview. Dry eye symptoms were assessed using the Ocular Surface Disease Index (OSDI) questionnaire and tear film stability by tear break-up time measurements (TBUT). Definite dry eye disease was defined as self-reported dry eye, confirmed by use of artificial tears and/or OSDI greater or equal to 22. Nine hundred and fifteen subjects, with mean age of 80 ± 4 years, returned the OSDI questionnaire. Of these, 271 (29.6%) subjects reported a dry eye disease and 135 (14.7%) were using artificial tears. An OSDI score > 22 was found in 359 (39.2%) subjects and a TBUT < 5 seconds in 335/746 (44.9%) subjects. Overall, definite dry eye affected 21.9% of subjects and was more frequent in women (27.1%) than in men (13.6%). After multivariate adjustment, dry eye disease was also significantly less frequent in subjects with high educational level (odds ratio (OR) = 0.49, 95% confidence interval (CI): 0.31-0.78 for long secondary school) and more frequent in subjects with ocular hypertension (OR = 1.61, 95% CI: 1.02-2.57) and those using anxiolytics (OR = 1.53, 95% CI: 1.02-2.29). This large observational study confirmed the high prevalence of dry eye symptoms among elderly subjects and confirmed some of the previously identified risk factors (in particular female gender and use of anxiolytics). © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Yildiz, Elvin H; Fan, Vincent C; Banday, Hina; Ramanathan, Lakshmi V; Bitra, Ratna K; Garry, Eileen; Asbell, Penny A
2009-07-01
To evaluate the repeatability and accuracy of a new tear osmometer that measures the osmolality of 0.5-microL (500-nanoliter) samples. Four standardized solutions were tested with 0.5-microL (500-nanoliter) samples for repeatability of measurements and comparability to standardized technique. Two known standard salt solutions (290 mOsm/kg H2O, 304 mOsm/kg H2O), a normal artificial tear matrix sample (306 mOsm/kg H2O), and an abnormal artificial tear matrix sample (336 mOsm/kg H2O) were repeatedly tested (n = 20 each) for osmolality with use of the Advanced Instruments Model 3100 Tear Osmometer (0.5-microL [500-nanoliter] sample size) and the FDA-approved Advanced Instruments Model 3D2 Clinical Osmometer (250-microL sample size). Four standard solutions were used, with osmolality values of 290, 304, 306, and 336 mOsm/kg H2O. The respective precision data, including the mean and standard deviation, were: 291.8 +/- 4.4, 305.6 +/- 2.4, 305.1 +/- 2.3, and 336.4 +/- 2.2 mOsm/kg H2O. The percent recoveries for the 290 mOsm/kg H2O standard solution, the 304 mOsm/kg H2O reference solution, the normal value-assigned 306 mOsm/kg H2O sample, and the abnormal value-assigned 336 mOsm/kg H2O sample were 100.3, 100.2, 99.8, and 100.3 mOsm/kg H2O, respectively. The repeatability data are in accordance with data obtained on clinical osmometers with use of larger sample sizes. All 4 samples tested on the tear osmometer have osmolality values that correlate well to the clinical instrument method. The tear osmometer is a suitable instrument for testing the osmolality of microliter-sized samples, such as tears, and therefore may be useful in diagnosing, monitoring, and classifying tear abnormalities such as the severity of dry eye disease.
Relevance of Lipid-Based Products in the Management of Dry Eye Disease.
Garrigue, Jean-Sébastien; Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M; Tong, Louis
2017-11-01
Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air-water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed.
Yokoi, N; Sonomura, Y; Kato, H; Komuro, A; Kinoshita, S
2015-09-01
To investigate the long-term results of 3% diquafosol ophthalmic solution as an alternative therapy to existing ophthalmic solutions, including topical immunosuppression, for the treatment of dry eye in patients with Sjögren's syndrome. This study involved 14 female dry-eye patients (mean age: 62.4 years) with Sjögren's syndrome who insufficiently responded to their current therapy. In all patients, 3% diquafosol ophthalmic solution was administered six times daily for 12 months in substitution for artificial tears and sodium hyaluronate ophthalmic solution. Their use of corticosteroid eye drops remained unchanged from that prior to the treatment with diquafosol sodium. The subjective symptoms assessed, and ocular signs including tear meniscus radius and the tear film breakup time, and ocular-surface epithelial damage score were examined at 1, 2, 3, 4, 5, 6, 9, and 12 months after initiating treatment. Among the subjective symptoms, significant improvement was obtained in dryness at 2 months post treatment, in eye fatigue at 1, 2, 3, 4, and 12 months post treatment, and in pain at 1, 2, 6, and 12 months post treatment. Difficulty in opening the eye, foreign body sensation, and redness were also significantly ameliorated at various time-points. The tear meniscus radius and the tear film breakup time were significantly improved throughout the observation period, and the corneal epithelial staining scores were significantly decreased at 3 months post treatment. In dry-eye patients with Sjögren's syndrome, treatment with 3% diquafosol ophthalmic solution improved both symptoms and signs, and that effectiveness was maintained for 12 months.
Kholinne, Erica; Lee, Hyun Joo; Kim, Sung Jung; Park, So Hyun; Jeon, In-Ho
2018-01-01
The aim of this study was to compare the microarchitecture of the greater tuberosity with or without rotator cuff tear and to obtain optimum location for anchor screw insertion for rotator cuff repair. Twenty-five humeral heads were harvested from 13 male cadavers of mean age 58.4 years, including 6 humeri with rotator cuff tear and 19 intact humeri. Six regions of interest (proximal, intermediate, and distal zones of the superficial and deep regions) were divided into the anterior (G1), middle (G2), and posterior (G3) areas of the greater tuberosity. Trabecular bone volume and cortical thickness were evaluated. Total trabecular bone volume was greater in subjects <50 years old than in subjects >50 years old but did not differ significantly in subjects with and without rotator cuff tear. Cortical thickness in both intact and torn rotator cuff groups was significantly greater in the proximal and intermediate zones than in the distal zone. Cortical thickness was related to anatomic location rather than age or cuff tear. The optimal location for anchor screw insertion during rotator cuff repair is either the proximal or intermediate region of the greater tuberosity. Age has more influence in terms of trabecular bone volume loss than rotator cuff integrity. Copyright © 2017. Production and hosting by Elsevier B.V.
Simmons, Peter A; Liu, Haixia; Carlisle-Wilcox, Cindy; Vehige, Joseph G
2015-01-01
Purpose To evaluate and compare the efficacy and safety of two investigational artificial tear formulations (CHO-1 and CHO-2) containing carmellose sodium, hyaluronic acid at different concentrations, and osmoprotectants, with a standard carmellose sodium-containing formulation (Refresh Tears [RT]) in the treatment of dry eye disease. Subjects and methods In this 3-month, double-masked, multicenter study, subjects (n=305) were randomized 1:1:1 to receive CHO-1, CHO-2, or RT, used as needed but at least twice daily. The primary endpoint was change in ocular surface disease index (OSDI) score from baseline to day 90. Other key outcomes included symptoms evaluated on a visual analog scale, corneal and conjunctival staining, and adverse events. Results OSDI scores and dry eye symptoms showed a rapid and sustained reduction from baseline in each group. Both CHO-1 and CHO-2 met the primary efficacy endpoint of noninferiority to RT in day 90 OSDI score change from baseline. OSDI ocular symptoms subscale improved more with CHO-1 than CHO-2 (P=0.048). In subjects with clinically relevant baseline ocular surface staining (>14 total score of a maximum of 55), day 90 improvements were greater with CHO-1 and CHO-2 than RT (P≤0.044). Day 90 improvements in OSDI ocular symptoms subscale scores were also greater with CHO-1 than RT (P<0.007) in subjects with clinically relevant ocular staining. All treatments were well tolerated. Conclusion Both combination artificial tear formulations were efficacious and well tolerated in subjects with dry eye. CHO-1 demonstrated the best performance in improving ocular symptoms and reducing ocular staining in this heterogeneous study population. PMID:25931807
Chung, So-Hyang; Lim, Sung A; Tchach, Hungwon
2016-02-01
To evaluate the efficacy and safety profile of carbomer-based lipid-containing artificial tear formulations (CBLAT) in patients with dry eye syndrome. A multicenter parallel-group study was conducted in 412 patients with dry eye syndrome. Of these patients, 221 switched from using artificial tears to CBLAT (switching group) and 191 added CBLAT to their current treatment (add-on group). Ocular symptom scores, ocular staining grades, tear film breakup time (tBUT), Schirmer I test value, and Korean dry eye level (as defined by the Korean Corneal Disease Study Group guidelines) were evaluated at baseline and after 4 weeks of treatment. After 4 weeks of treatment, ocular surface staining grade, tBUT, Schirmer I value, ocular irritation symptom scores, and the positive rate of visual symptom improved significantly in both groups. Mean reductions in ocular surface staining grades (-0.8 ± 0.9) and ocular irritation symptom scores (-0.8 ± 0.8) in the add-on group were significantly higher than those (-0.5 ± 0.8 and -0.6 ± 0.8) in the switching group (P < 0.01 and P < 0.05). The positive rate of visual symptoms (44.2%) in the add-on group was significantly higher than that (26.4%) in the switching group (P < 0.01). The decrease of Korean dry eye level was 30.1% in the switching group and 51.6% in the add-on group. More patients in the add-on group had decreased dry eye levels than those in the switching group (P < 0.0001). CBLAT improves ocular surface staining grades, tBUT, Schirmer I values, and ocular symptoms in patients with dry eye syndrome.
21 CFR 886.1800 - Schirmer strip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... device made of filter paper or similar material intended to be inserted under a patient's lower eyelid to stimulate and evaluate formation of tears. (b) Classification. Class I (general controls). If the device is...
Full-thickness tears of the supraspinatus tendon: A three-dimensional finite element analysis.
Quental, C; Folgado, J; Monteiro, J; Sarmento, M
2016-12-08
Knowledge regarding the likelihood of propagation of supraspinatus tears is important to allow an early identification of patients for whom a conservative treatment is more likely to fail, and consequently, to improve their clinical outcome. The aim of this study was to investigate the potential for propagation of posterior, central, and anterior full-thickness tears of different sizes using the finite element method. A three-dimensional finite element model of the supraspinatus tendon was generated from the Visible Human Project data. The mechanical behaviour of the tendon was fitted from experimental data using a transversely isotropic hyperelastic constitutive model. The full-thickness tears were simulated at the supraspinatus tendon insertion by decreasing the interface area. Tear sizes from 10% to 90%, in 10% increments, of the anteroposterior length of the supraspinatus footprint were considered in the posterior, central, and anterior regions of the tendon. For each tear, three finite element analyses were performed for a supraspinatus force of 100N, 200N, and 400N. Considering a correlation between tendon strain and the risk of tear propagation, the simulated tears were compared qualitatively and quantitatively by evaluating the volume of tendon for which a maximum strain criterion was not satisfied. The finite element analyses showed a significant impact of tear size and location not only on the magnitude, but also on the patterns of the maximum principal strains. The mechanical outcome of the anterior full-thickness tears was consistently, and significantly, more severe than that of the central or posterior full-thickness tears, which suggests that the anterior tears are at greater risk of propagating than the central or posterior tears. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tong, Louis; Beuerman, Roger; Simonyi, Susan; Hollander, David A; Stern, Michael E
2016-04-01
To investigate changes in signs, symptoms, and tear cytokines following punctal plug occlusion in patients with dry eye. A single-center study was conducted at Singapore Eye Research Institute. Nonabsorbable punctal plugs were inserted in the lower punctum of both eyes in patients with moderate dry eye. Over 3 weeks, in the more severe eye, dry eye symptoms, fluorescein corneal staining, Schirmer I (without topical anesthesia) test, tear film breakup time (TFBUT), and safety were assessed. Cytokine and matrix metalloproteinase-9 (MMP-9) levels in tear samples were measured. Twenty-nine patients (mean age 49.8 years) with moderate dry eye were evaluated. At baseline, mean (standard deviation) global symptoms score was 53.8 (26.5), Schirmer I test score was 5.1 (2.8) mm, and TFBUT was 2.2 (0.6) seconds. After 3 weeks, punctal occlusion significantly reduced global irritation symptoms score (P<.001) and decreased fluorescein staining in all zones (P<.01) except the inferior zone (P=.42). No significant association between levels of cytokines or MMP-9 and either TFBUT or global irritation symptoms were observed at baseline. Levels of several cytokines and MMP-9 were higher in patients with Schirmer I test scores ≤8 mm at baseline. After 3 weeks of punctal occlusion, no significant changes in overall cytokine or MMP-9 levels were observed. Punctal plug occlusion provided symptomatic relief and reduced fluorescein staining in all except the inferior zone. However, insertion of punctal plugs had minimal effect on tear cytokines and MMP-9 levels, suggesting a need for earlier treatment with anti-inflammatory agents for management of dry eye disease. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Murray, Iain R.; LaPrade, Robert F.; Musahl, Volker; Geeslin, Andrew G.; Zlotnicki, Jason P.; Mann, Barton J.; Petrigliano, Frank A.
2016-01-01
Rotator cuff tears are common and result in considerable morbidity. Tears within the tendon substance or at its insertion into the humeral head represent a considerable clinical challenge because of the hostile local environment that precludes healing. Tears often progress without intervention, and current surgical treatments are inadequate. Although surgical implants, instrumentation, and techniques have improved, healing rates have not improved, and a high failure rate remains for large and massive rotator cuff tears. The use of biologic adjuvants that contribute to a regenerative microenvironment have great potential for improving healing rates and function after surgery. This article presents a review of current and emerging biologic approaches to augment rotator cuff tendon and muscle regeneration focusing on the scientific rationale, preclinical, and clinical evidence for efficacy, areas for future research, and current barriers to advancement and implementation. PMID:27099865
Changes in the tear film and ocular surface from dry eye syndrome.
Johnson, Michael E; Murphy, Paul J
2004-07-01
Dry eye syndrome (DES) refers to a spectrum of ocular surface diseases with diverse and frequently multiple aetiologies. The common feature of the various manifestations of DES is an abnormal tear film. Tear film abnormalities associated with DES are tear deficiency, owing to insufficient supply or excessive loss, and anomalous tear composition. These categorizations are artificial, as in reality both often coexist. DES disrupts the homeostasis of the tear film with its adjacent structures, and adversely affects its ability to perform essential functions such as supporting the ocular surface epithelium and preventing microbial invasion. In addition, whatever the initial trigger, moderate and severe DES is characterized by ocular surface inflammation, which in turn becomes the cause and consequence of cell damage, creating a self-perpetuating cycle of deterioration. Progress has been made in our understanding of the aetiology and pathogenesis of DES, and these advances have encouraged a proliferation of therapeutic options. This article aims to amalgamate prevailing ideas of DES development, and to assist in that, relevant aspects of the structure, function, and production of the tear film are reviewed. Additionally, a synopsis of therapeutic strategies for DES is presented, detailing treatments currently available, and those in development.
Almubrad, Turki M; Alshehri, Fayez H; Ogbuehi, Kelechi C; Osuagwu, Uchechukwu L
2013-06-01
To compare the effect of nonpreserved oxybuprocaine and preserved artificial tears on central corneal thickness (CCT) obtained by 2 pachymeters. In this prospective, placebo-controlled study, involving a random sample of 100 eyes of 50 subjects, aged 24±2.3 years, CCT readings were obtained in 2 separate sessions with the Topcon SP-3000P and ultrasound pachymetry (USP), respectively, before, 5 and 10 min after instillation of a drop each of either oxybuprocaine hydrochloride (oxybuprocaine HCl) (group 1) or carboxymethylcellulose sodium, thera tears (group 2), and placebo. The baseline mean CCT for SP-3000P was 509±38 μm and 542±36 μm for USP. No statistical significant differences between baseline CCTs (P>0.05 for both devices) in both groups. In both group experimental eyes, neither SP-3000P nor USP-measured CCTs varied significantly from the control eyes at 5 (P>0.05) and 10 (P>0.05) mins postinstillation of drops in both sessions. In group one, the 95% confidence intervals (CIs) for the SP-3000P CCTs were similar at 5 (-16 to 17 μm) and 10 min (-16 to 17 μm), but in the USP-measured CCTs, it was wider at 10 min (-41 to 46 μm) than at 5 min (-30 to 41 μm) postinstillation. In group two, the 95% CIs at 5 and 10 mins postinstillation, respectively, ranged between -20 and 47 μm, -21 and 43 μm (SP-3000P) and -29 and 23 μm, -26 and 23 μm (USP). Within groups and between groups, variations in CCT were similar at both times intervals in all comparisons. Although oxybuprocaine HCl and thera tears consistently did not affect the mean CCT obtained by both devices at both time intervals, variation in SP-3000P measured CCT was more consistent in both sessions and narrower in relation to USP-measured CCT. It may be reasonable to suggest that measurements of CCT in normal patients be taken before examinations requiring instillation of anesthetics or such measurements when obtained postinstillation of either oxybuprocaine or preserved artificial tears be interpreted with caution.
Relevance of Lipid-Based Products in the Management of Dry Eye Disease
Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M.; Tong, Louis
2017-01-01
Abstract Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air–water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed. PMID:28956698
Management of dry eye disease.
Lemp, Michael A
2008-04-01
The management of dry eye disease (DED) encompasses both pharmacologic and nonpharmacologic approaches, including avoidance of exacerbating factors, eyelid hygiene, tear supplementation, tear retention, tear stimulation, and anti-inflammatory agents. Artificial tears are the mainstay of DED therapy but, although they improve symptoms and objective findings, there is no evidence that they can resolve the underlying inflammation in DED. Topical corticosteroids are effective anti-inflammatory agents, but are not recommended for long-term use because of their adverse-effect profiles. Topical cyclosporine--currently the only pharmacologic treatment approved by the US Food and Drug Administration specifically for DED--is safe for long-term use and is disease-modifying rather than merely palliative. Treatment selection is guided primarily by DED severity. Recently published guidelines propose a severity classification based on clinical signs and symptoms, with treatment recommendations according to severity level.
Herok, George Henryk; Mudgil, Poonam; Millar, Thomas James
2009-07-01
The lipid layer of the tear film is associated with preventing evaporative loss. The ability of human Meibomian lipids to reduce evaporation in vitro was tested. Films of human or animal Meibomian lipids or mixtures of cholesterol and phosphatidylcholine were spread on the surface of either artificial buffer or on whole tears and placed on a mass balance that was enclosed in a sealed chamber. The temperature was adjusted to 37 degrees C and gas flow was controlled. Increasing the amounts of Meibomian lipids gave a very small reduction in evaporation. It was concluded from these in vitro experiments that prevention of evaporation from the tear film is not due to the Meibomian lipids alone, but is more likely to be due to a complex interaction between components of the aqueous and the Meibomian lipids.
Laparoscopic insertion of artificial periprostatic urinary sphincter.
Gamé, Xavier; Bram, Raphael; Abu Anz, Sami; Doumerc, Nicolas; Guillotreau, Julien; Malavaud, Bernard; Rischmann, Pascal
2009-02-01
The objective of this case report is to describe the laparoscopic insertion of an artificial periprostatic urinary sphincter. We report the case of a paraplegic patient in whom an artificial urinary sphincter was inserted in a periprostatic position by way of laparoscopy to treat stress urinary incontinence. In addition to laparoscopy being minimally invasive, its advantages include the excellent quality of retroprostatic dissection and the perfect visualization it gives at the level of cuff positioning with respect to the anatomic landmarks. It is more appropriate to be able to cleave the interprostatorectal space to ensure passage of the cuff under perfectly safe conditions.
Ipsilateral Medial and Lateral Discoid Meniscus with Medial Meniscus Tear
Shimozaki, Kengo; Nakase, Junsuke; Ohashi, Yoshinori; Numata, Hitoaki; Oshima, Takeshi; Takata, Yasushi; Tsuchiya, Hiroyuki
2016-01-01
Introduction: Discoid meniscus is a well-documented knee pathology, and there are many cases of medial or lateral discoid meniscus reported in the literature. However, ipsilateral concurrent medial and lateral discoid meniscus is very rare, and only a few cases have been reported. Herein, we report a case of concurrent medial and lateral discoid meniscus. Case Report: A 27-year-old Japanese man complained of pain on medial joint space in his right knee that was diagnosed as a complete medial and lateral discoid meniscus. In magnetic resonance imaging, although the lateral discoid meniscus had no tear, the medial discoid meniscus had a horizontal tear. Arthroscopic examination of his right knee similarly revealed that the medial discoid meniscus had a horizontal tear. In addition, the discoid medial meniscus also had an anomalous insertion to the anterior cruciate ligament, and there was also mild fibrillation of the medial tibial cartilage surface. We performed arthroscopic partial meniscectomy for the torn medial discoid meniscus but not for the asymptomatic lateral discoid meniscus. The latest follow-up at 18 months indicated satisfactory results. Conclusion: We report a rare case of ipsilateral medial and lateral discoid meniscus with medial meniscus tear. The medial discoid meniscus with tear was treated with partial meniscectomy, whereas the lateral discoid meniscus without tear was only followed up. PMID:28164045
Rotator cuff tears in children and adolescents: experience at a large pediatric hospital.
Zbojniewicz, Andrew M; Maeder, Matthew E; Emery, Kathleen H; Salisbury, Shelia R
2014-06-01
Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between rotator cuff tears and physeal patency (P > 0.05). Most patients were athletes (76%). Five tears were confirmed at surgery. Poor clinical follow-up limited evaluation of patient outcomes. Rotator cuff tears can be identified during MRI examination of symptomatic child and adolescent shoulders and often consist of tear patterns associated with repetitive microtrauma in overhead athletic activities or with single traumatic events. Rotator cuff tears are seen throughout the range of skeletal maturity, often coexist with labral tears and typically are found in athletes.
Lenart, S B; Garrity, J A
2000-05-01
The presence of a corneal reflex and the ability to maintain eye closure are instrumental in protecting the cornea. Use of neuromuscular blocking agents or propofol can result in impaired eyelid closure and loss of corneal reflex, leading to corneal exposure. The cornea is then at risk for drying, infection, and scarring, which may lead to permanent visual loss. To determine whether applying artificial tear ointment to the eyes of paralyzed or heavily sedated patients receiving mechanical ventilation decreases the prevalence of exposure keratitis more than does passive closure of the eyelid. A prospective, randomized control trial was done. The sample was 50 patients in the intensive care unit receiving either neuromuscular blocking agents or propofol during mechanical ventilation. In each patient, artificial tear ointment was applied to one eye; passive closure of the eyelid was used for the other eye (control eye). Nine patients had evidence of exposure keratitis in the untreated eye, and 2 had corneal abrasions in both the treated and the control eyes. The remaining 39 patients did not have corneal abrasions in either eye. Use of the artificial tear ointment was more effective in preventing corneal exposure than was passive eyelid closure (P = .004). Eye care with a lubricating ointment on a regular, set schedule can effectively reduce the prevalence of corneal abrasions in patients who are either paralyzed or heavily sedated and thus can help prevent serious complications such as corneal ulceration, infection, and visual loss.
Bartlett, Jimmy D; Holland, Edward J; Usner, Dale W; Paterno, Michael R; Comstock, Timothy L
2008-08-01
To compare the ocular comfort and tolerability of loteprednol etabonate 0.5%/tobramycin 0.3% (LE/T; Zylet) with dexamethasone 0.1%/tobramycin 0.3% (DM/T; TobraDex) in healthy volunteers. In this multicenter, randomized, double-masked, parallel-group study, healthy volunteers (n = 306) were randomized to receive LE/T or DM/T four times per day for 28 days. Subjects recorded subjective ratings for seven comfort/tolerability parameters using an electronic patient diary (EPD). The primary endpoint was the difference at week 4 from the ratings of an artificial tear at baseline in comfort/tolerability parameters between treatment groups, using a noninferiority paradigm. ClinicalTrials. gov, NCT 00532961. The 97.5% confidence intervals for the lower bound were within -10 for all of the seven comfort/ tolerability parameters evaluated (pain, stinging/burning, irritation, itchiness, foreign-body sensation, dryness, and light sensitivity). Secondary analysis revealed small but significant within-treatment differences in pain favoring LE/T over tears and in light sensitivity favoring tears over DM/T (p < 0.01). Small between-treatment differences in the changes from baseline tear ratings to individual study visits favored LE/T for pain, stinging/burning, irritation, itchiness, foreign-body sensation, and light sensitivity at visit 4 (p < or = 0.04); for pain, stinging/burning, and foreignbody sensation at visit 5 (p < or = 0.03), and for dryness and light sensitivity at visit 6 (p < or = 0.05). LE/T satisfied all conditions of noninferiority to DM/T in comfort and tolerability. Subjects receiving LE/T were more likely to report better ocular comfort/tolerability ratings relative to baseline artificial tears than subjects receiving DM/T. The study population consisted of healthy volunteers.
Safonova, T N; Gladkova, О V; Boev, V I
2016-01-01
Laser confocal tomography of the cornea enables studying ultrathin sections of corneal layers, which provides additional reliable information on tissue changes in keratoconjunctivitis sicca (KCS). To assess the significance of laser confocal tomography of the cornea in the diagnosis and monitoring of KCS. We investigated 38 eyes of 30 patients with severe KCS. The patients were divided into two groups. Group 1 (15 patients, 19 eyes) was prescribed cyclosporine А 0.05% instillations 2 times daily, artificial tears, and soft contact lenses. Group 2 (15 patients, 19 eyes) received only instillations of cyclosporine А 0.05% 2 times daily and artificial tears. Besides standard ophthalmic examination, additional tests were performed, namely Schirmer's test, tear break-up time test, fluorescein eye stain test, tear osmolarity test (TearLab System, USA), and Heidelberg retinal tomography of the cornea (HRT, Heidelberg Engineering GmbH, Germany). HRT findings revealed a 3 times shorter epithelization period and faster recovery of corneal transparency in group 1 as compared to group 2 (1.5 and 4.5 months, respectively). There was also an evident reduction in the number of immune cells in the cornea, most pronounced in group 1 at 3 months, which is indicative of inflammation termination. The use of HRT of the cornea in KCS patients allows real-time cellular level observation of corneal changes, which together with clinical findings and diagnostic tests not only confirms the diagnosis but also determines treatment effectiveness. It has been also found that soft contact lenses accelerate epithelization of the cornea and relieve inflammation of the ocular surface in KCS patients under cyclosporine A 0.05% instillation therapy. Transparency of financial activity: the authors have no financial interest in the submitted materials and methods.
Hirata, Harumitsu; Mizerska, Kamila; Marfurt, Carl F.; Rosenblatt, Mark I.
2015-01-01
Purpose In an effort to elucidate possible neural mechanisms underlying diminished tearing in dry eye disease, this study sought to determine if hyperosmolar tears, a ubiquitous sign of dry eye disease, produce functional changes in corneal nerve responses to drying of the cornea and if these changes correlate with alterations in corneal nerve morphology. Methods In vivo extracellular electrophysiological recordings were performed in rat trigeminal ganglion neurons that innervated the cornea before, and up to 3 hours after, the ocular application of continuous hyperosmolar tears or artificial tears. In corollary experiments, immunohistochemical staining was performed to compare corneal nerve morphology in control and in eyes treated with hyperosmolar solutions. Results Our previous studies identified a population of corneal afferents, dry-sensitive neurons that are strongly excited by corneal dessication (“dry response”), a response thought to trigger the lacrimation reflex. In the present study, we found that the dry responses of corneal dry-sensitive neurons were depressed or even completely abolished by hyperosmolar tears in a time- (30 minutes to 3 hours) and dose (450- to 1000-mOsm solutions)-dependent manner. Furthermore, eyes treated with hyperosmolar tears for 3 hours contained large numbers of morphologically abnormal (granular, fragmented, or prominently beaded) subbasal nerves that appeared to be undergoing degeneration. Conclusions These results demonstrate that tear hyperosmolarity, considered to be a “core” mechanism of dry eye disease, significantly decreases physiological sensitivity and morphologic integrity of the corneal nerves important in tear production. These alterations might contribute to the diminished tearing seen clinically in dry eye patients. PMID:26720465
Hirata, Harumitsu; Mizerska, Kamila; Marfurt, Carl F; Rosenblatt, Mark I
2015-12-01
In an effort to elucidate possible neural mechanisms underlying diminished tearing in dry eye disease, this study sought to determine if hyperosmolar tears, a ubiquitous sign of dry eye disease, produce functional changes in corneal nerve responses to drying of the cornea and if these changes correlate with alterations in corneal nerve morphology. In vivo extracellular electrophysiological recordings were performed in rat trigeminal ganglion neurons that innervated the cornea before, and up to 3 hours after, the ocular application of continuous hyperosmolar tears or artificial tears. In corollary experiments, immunohistochemical staining was performed to compare corneal nerve morphology in control and in eyes treated with hyperosmolar solutions. Our previous studies identified a population of corneal afferents, dry-sensitive neurons that are strongly excited by corneal dessication ("dry response"), a response thought to trigger the lacrimation reflex. In the present study, we found that the dry responses of corneal dry-sensitive neurons were depressed or even completely abolished by hyperosmolar tears in a time- (30 minutes to 3 hours) and dose (450- to 1000-mOsm solutions)-dependent manner. Furthermore, eyes treated with hyperosmolar tears for 3 hours contained large numbers of morphologically abnormal (granular, fragmented, or prominently beaded) subbasal nerves that appeared to be undergoing degeneration. These results demonstrate that tear hyperosmolarity, considered to be a "core" mechanism of dry eye disease, significantly decreases physiological sensitivity and morphologic integrity of the corneal nerves important in tear production. These alterations might contribute to the diminished tearing seen clinically in dry eye patients.
Effect of extraoral aging conditions on mechanical properties of maxillofacial silicone elastomer.
Hatamleh, Muhanad M; Polyzois, Gregory L; Silikas, Nick; Watts, David C
2011-08-01
The purpose of this study was to investigate the effect of extraoral human and environmental conditions on the mechanical properties (tensile strength and modulus, elongation, tear strength hardness) of maxillofacial silicone elastomer. Specimens were fabricated using TechSil-S25 silicone elastomer (Technovent Ltd, Leeds, UK). Eight groups were prepared (21 specimens in each group; eight tensile, eight tear, five hardness) and conditioned differently as follows (groups 1 through 8): Dry storage for 24 hours; dry storage in dark for 6 months; storage in simulated sebum solution for 6 months; storage in simulated acidic perspiration for 6 months; accelerated artificial daylight aging under controlled moisture for 360 hours; outdoor weathering for 6 months; storage in antimicrobial silicone-cleaning solution for 30 hours; and mixed conditioning of sebum storage and light aging for 360 hours. The conditioning period selected simulated a prosthesis being in service for up to 12 months. Tensile and tear test specimens were fabricated and tested according to the International Standards Organization (ISO) standards no. 37 and 34, respectively. Shore A hardness test specimens were fabricated and tested according to the American Standards for Testing and Materials (ASTM) D 2240. Data were analyzed with one-way ANOVA, Bonferroni, and Dunnett's T3 post hoc tests (p < 0.05). Weibull analysis was also used for tensile strength and tear strength. Statistically significant differences were evident among all properties tested. Mixed conditioning of simulated sebum storage under accelerated artificial daylight aging significantly degraded mechanical properties of the silicone (p < 0.05). Mechanical properties of maxillofacial elastomers are adversely affected by human and environmental factors. Mixed aging of storage in simulated sebum under accelerated daylight aging was the most degrading regime. Accelerated aging of silicone specimens in simulated sebum under artificial daylight for 12 months of simulated clinical service greatly affected functional properties of silicone elastomer; however, in real practice, the effect is modest, since sebum concentration is lower, and daylight is less concentrated. © 2011 by The American College of Prosthodontists.
Allergy and allergic mediators in tears.
Leonardi, Andrea
2013-12-01
The identification of inflammatory mediators in the tear fluid have been extensively used in ocular allergy to find either a 'disease marker', to better understand the immune mechanisms involved in the ocular surface inflammation, or to identify potential targets for therapeutic interventions. While the clinical characteristics allow a relatively convincing diagnosis of ocular allergic diseases, in the initial, non active phases, or in the chronic stages, the diagnosis may not be clear. Although not highly specific, total tear IgE can be measured with local tests by inserting a paper strip in the lower meniscus. The measurement of tear specific inflammatory markers, such as histamine, tryptase, ECP, IL-4, IL-5 and eotaxin, may be useful for the diagnosis or monitoring ocular allergy. New technologies such as multiplex bead assays, membrane-bound antibody array and proteomic techniques can characterize the distribution of a wide range of bioactive trace proteins in tears. Dozens of mediators, cytokines, chemokines, growth factors, angiogenic modulators, enzymes and inhibitors were thus identified in small tear samples using these techniques, providing the possible identification of specific biomarker for either specific disease or disease activity. However, to date, there is no a single specific laboratory test suitable for the diagnosis and monitoring of allergic conjunctivitis. Copyright © 2013 Elsevier Ltd. All rights reserved.
Edwards, Peter; Ebert, Jay; Joss, Brendan; Bhabra, Gev; Ackland, Tim; Wang, Allan
2016-01-01
The incidence of rotator cuff tears increases with age, with full-thickness rotator cuff tears present in approximately 25% of individuals in their sixties, and more than 50% of those in their eighties. While surgery is considered an effective treatment, recurrent tears at the insertion site are common, especially with degenerative tears, which are frequent in the older population. More recently, there has been increasing interest in exercise rehabilitation and physical therapy as a means to manage partial and full thickness tears of the rotator cuff by addressing weakness and functional deficits. Recent studies have suggested that patients opting for physical therapy have demonstrated high satisfaction, an improvement in function, and success in avoiding surgery. When considering the increasing rate of shoulder surgery and the associated economic and social burden rotator cuff surgery places on both the patient and the health care system, non-surgical management such as physical therapy and exercise may, in selected cases, be a treatment alternative to surgical repair. The purpose of this clinical commentary is to provide an overview of rotator cuff pathology and pathogenesis, and to present an evidence-based case for the role of conservative rehabilitation in the management of rotator cuff injuries. Level of Evidence Level 5 PMID:27104061
Influence of artificial cavity age on red-cockaded woodpecker translocation success
Daniel Saenz; Richard R. Schaefer; Richard N. Conner; D. Craig Rudolph; Dawn K. Carrie; M. Stephen Best
2004-01-01
Red-cockaded woodpecker (Picoides borealis) translocations have been used to bolster woodpecker populations and to fill breeding vacancies. Artificial, insert cavities have been used to offset cavity shortages in woodpecker clusters and are the primary cavity type used in recruitment clusters in Texas and Arkansas, but inserts may lose their...
Fishtail on a line technique for capsular tension ring insertion.
Rixen, Jordan J; Oetting, Thomas A
2014-07-01
We describe a capsular tension ring (CTR) insertion technique that is a modification of the previously described fishtail technique. A suture line is used to pull the leading eyelet out through the main incision to form the fish configuration. Similar to the fishtail technique, this insertion technique minimizes the risk for zonular damage or a capsule tear because the CTR is not dialed into the capsular bag. The advantage of the suture line is that it prevents over bending of the CTR during insertion through the main incision, which can occur using the traditional fishtail technique. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
From the RSNA refresher courses: US of the rotator cuff: pitfalls, limitations, and artifacts.
Rutten, Matthieu J C M; Jager, Gerrit J; Blickman, Johan G
2006-01-01
High-resolution ultrasonography (US) has gained increasing popularity as a diagnostic tool for assessment of the soft tissues in shoulder impingement syndrome. US is a powerful and accurate method for diagnosis of rotator cuff tears and other rotator cuff abnormalities, provided the examiner has a detailed knowledge of shoulder anatomy, uses a standardized examination technique, and has a thorough understanding of the potential pitfalls, limitations, and artifacts. False-positive sonographic findings of rotator cuff tears can be caused by the technique (anisotropy, transducer positioning, acoustic shadowing by the deltoid septum), by the anatomy (rotator cuff interval, supraspinatus-infraspinatus interface, musculotendinous junction, fibrocartilaginous insertion), or by disease (criteria for diagnosis of rotator cuff tears, tendon inhomogeneity, acoustic shadowing by scar tissue or calcification, rotator cuff thinning). False-negative sonographic findings of rotator cuff tears can be caused by the technique (transducer frequency, suboptimal focusing, imaging protocol, transducer handling), by the anatomy (nondiastasis of the ruptured tendon fibers, posttraumatic obscuration of landmarks), by disease (tendinosis, calcifications, synovial proliferation, granulation or scar tissue, bursal thickening, massive rotator cuff tears), or by patient factors (obesity, muscularity, limited shoulder motion). (c) RSNA, 2006.
Assessment of tear osmolarity and other dry eye parameters in post-LASIK eyes.
Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo; Nemeth, Gabor
2013-07-01
To assess the tear osmolarity using the TearLab device after laser in situ keratomileusis (LASIK) and to compare the values with those obtained by traditional tear film tests before and after the procedure. Thirty eyes of 15 refractive surgery candidates (5 men and 10 women of mean age: 30.55 ± 11.79 years) were examined. Using a special questionnaire (Ocular Surface Disease Index), subjective dry eye complaints were evaluated, and then, the tear osmolarity was measured with the TearLab system (TearLab Corporation) and conventional dry eye tests were carried out. Examinations were performed preoperatively and at 1, 30, and 60 days after the surgery. The mean value of tear osmolarity was 303.62 ± 12.29 mOsm/L before the surgery and 303.58 ± 20.14 mOsm/L at 60 days after the treatment (P = 0.69). Mean lid parallel conjunctival folds value was 0.68 ± 0.68 before the procedure and 0.58 ± 0.65 subsequent to surgery (P = 0.25). Meibomian gland dysfunction was not detected. No significant deviation was observed in the values of Schirmer test, corneal staining, tear break-up time, and lid parallel conjunctival folds when compared with postoperatively obtained values during the follow-up period (P > 0.05). During LASIK flap creation, intact corneal innervation is damaged, and the ocular surface lacrimal functional unit can be impaired. In our study, no abnormal dry eye test results were observed before or after the procedure. Based on our results, LASIK treatment is safe for dry eye involving the administration of adequate artificial tears for a minimum of 3 months.
Tear film measurement by optical reflectometry technique
Lu, Hui; Wang, Michael R.; Wang, Jianhua; Shen, Meixiao
2014-01-01
Abstract. Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle. PMID:24500519
Cytokine changes in tears and relationship to contact lens discomfort.
Willcox, Mark D P; Zhao, Zhenjun; Naduvilath, Thomas; Lazon de la Jara, Percy
2015-01-01
To determine the reproducibility of a multiplex bead assay for measuring cytokines in tears and correlations between ocular discomfort with or without contact lens wear and the concentration of cytokines in tears. Ninety participants (divided into two groups) were enrolled in this prospective study. They were asked to rate their ocular comfort and collect their tears in the morning and just before sleep for 10 days with or without contact lenses. The participants collected their tears using a glass microcapillary tube for both stages. Galyfilcon A lenses were worn on a daily disposable basis during the contact lens stage, and comfort scores and tears were collected before lens insertion and prior to lens removal at the end of the day. Tears were analyzed for cytokine concentrations using a 27-plex multibead assay. Correlations were sought between cytokine concentrations and comfort. There was a significant (p<0.022) decrease in ocular comfort over the day with or without lens wear. The magnitude of ocular discomfort was significantly greater (p<0.009) with lens wear. The concentrations of 12 cytokines differed significantly between the groups; thus, these cytokines were not analyzed further. For the remaining 15 cytokines, interleukin-8 (IL-8) was the only cytokine that changed in both groups during the day without (reduced by >-0.5 Log pg/ml, p<0.001) or with lens wear (reduced by >-0.2 Log pg/ml, p<0.001). The change in the vascular endothelial growth factor (VEGF) concentration only in tears was correlated to ocular comfort, but this was not changed by contact lens wear. Ocular comfort during the day is magnified by contact lens wear. However, the increase in the change in comfort during lens wear was not associated with changes in 15 cytokines in the tear film.
21 CFR 872.3900 - Posterior artificial tooth with a metal insert.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Posterior artificial tooth with a metal insert. 872.3900 Section 872.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... surrounding teeth by a bridge and is intended to provide both an improvement in appearance and functional...
21 CFR 872.3900 - Posterior artificial tooth with a metal insert.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Posterior artificial tooth with a metal insert. 872.3900 Section 872.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... surrounding teeth by a bridge and is intended to provide both an improvement in appearance and functional...
Kaido, Minako; Kawashima, Motoko; Shigeno, Yuta; Yamada, Yoshiaki; Tsubota, Kazuo
2018-05-01
Complex mechanisms underlie dry eye (DE) symptom provocation. In particular, corneal hypersensitivity may provoke symptoms in short tear break-up time (BUT) DE characterized by tear film instability. We hypothesized that improved tear film stability may alleviate corneal sensitivity in patients with short tear BUT DE. Therefore, we investigated the effect of topical diquafosol tetrasodium (DQS) on corneal sensitivity in unstable tear film DE. This prospective, randomized study included 27 subjects (age: 39.1 ± 8.4 years; range: 25-59 years) with short tear BUT DE, defined based on the presence of DE symptoms and tear film instability. Subjects were randomly divided into DQS (3% DQS, 12 subjects) and artificial tear (AT; preservative-free AT, 15 subjects) groups. Subjects applied the medication 6 times a day for 5 weeks. The perception of touch (S-touch) and pain (S-pain) sensitivity was measured using a Cochet-Bonnet esthesiometer. Tear evaluation, corneal sensitivity, and DE symptoms were compared before and after DQS or AT administration. The correlation between the improvement degrees of corneal sensitivity and DE symptoms following medication was analyzed. DQS significantly improved tear BUT and tear meniscus height (TMH) scores (p < 0.05), while AT significantly improved tear BUT (p < 0.05) but not TMH score. Mean S-pain and DE symptom scores were lower after medication use in the DQS (S-pain and DE symptoms: p < 0.05) and AT groups (S-pain: p = 0.05; DE symptoms: p < 0.05). However, S-touch did not change significantly in either group. A positive correlation was observed between the improvement degrees of S-pain and DE symptoms in the overall subjects studied. Both DQS and AT alleviate corneal hypersensitivity and DE symptoms in eyes with short tear BUT DE. However, DQS seems to be more effective to adjust tear environment, leading to the normalization of corneal sensitivity and DE symptoms. UMIN Clinical Trials Registry Identifier, UMIN000014536.
Zhu, Lei; Zhang, Cheng; Chuck, Roy S
2012-01-01
To evaluate the effect of the topical steroid, fluorometholone, and the non-steroidal anti-inflammatory drugs (NSAIDs), nepafenac and ketorolac, on inflammatory cytokine expression of the ocular surface in the botulium toxin B-induced murine dry eye model. Topical artificial tears (0.5% carboxymethylcellulose sodium), 0.1% fluorometholone, 0.1% nepafenac, and 0.4% ketorolac were applied 3 times per day in a dry eye mouse model 1 week after intralacrimal botulium toxin B (BTX-B) or saline (sham) injection. Tear production and corneal fluorescein staining were evaluated in all groups before injection at baseline and at 3 time points up to 4 weeks after injection. The pro-inflammatory cytokines interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α) were evaluated by immunohistochemistry. BTX-B-injected mice showed significantly decreased aqueous tear production and increased corneal fluorescein staining at the 1 and 2 week time points compared with normal control and saline-injected mice. In the BTX-B-injected mice, immunofluorescent staining for TNF-α and IL-1β in corneal and conjunctival epithelial cells increased significantly at the 2 and 4 week time points compared to that of normal and saline-injected mice, and returned to normal levels at the 4 week time point. Topical fluorometholone significantly improved corneal surface staining in the BTX-B-injected mice after 1 week of treatment, and increased the tear production within 2 weeks, but without statistical significant difference. Topical fluorometholone significantly decreased the staining of TNF-α and IL-1β in corneal and conjunctival epithelia after 1-week treatment. Topical artificial tears, 0.1% nepafenac, and 0.4% ketorolac did not show obvious effects on tear production, corneal surface staining, and levels of IL-1β and TNF-α expression in normal, and BTX-B-injected dry eye mice. Topical fluorometholone caused suppression of inflammatory cytokine expression on the ocular surface in the Botulium toxin B-induced murine dry eye model, while topical NSAIDs demonstrated no clearly beneficial effects.
Kim, Yung Hui; Kang, Yeon Soo; Lee, Hyo Seok; Choi, Won; You, In Cheon; Yoon, Kyung Chul
2017-10-01
The aim of this study was to evaluate the effectiveness of combined tear film therapy targeted to aqueous, mucin, and lipid layers in patients with refractory evaporative dry eye (EDE) with short tear film breakup time (TBUT). The patients who had EDE with short TBUT and severe symptoms refractory to artificial tears were treated with hyaluronic acid (HA) 0.15% and diquafosol tetrasodium (DQS) 3% (Group 1), HA and carbomer-based lipid-containing eyedrops (Liposic EDO Gel, LPO) (Group 2), or HA, DQS, and LPO (Group 3). Ocular Surface Disease Index (OSDI) score, visual analog scale (VAS) symptom score, TBUT, Schirmer score, and corneal and conjunctival staining scores were evaluated, and noninvasive tear film breakup time (NIBUT) and tear meniscus height were measured using Keratograph ® 5 M before and 1 and 3 months after treatment. OSDI scores, VAS scores, TBUT, and NIBUT were improved at 1 and 3 months after treatment in all groups (all P < 0.05). At each follow-up visit, the total OSDI, OSDI symptom, and all VAS scores were significantly lower in group 3 compared with groups 1 and 2 (all P < 0.05). In addition, TBUT and NIBUT were significantly higher in group 3 compared with groups 1 and 2 (all P < 0.05). No significant adverse effects were noted in the groups during treatment. Mucin or lipid-targeting agents combined with aqueous supplements in patients with refractory EDE with short TBUT might improve subjective symptoms and TBUT. Of this, targeting whole tear film layers was most effective in improving ocular symptoms and tear film quality.
Dry eye syndrome among computer users
NASA Astrophysics Data System (ADS)
Gajta, Aurora; Turkoanje, Daniela; Malaescu, Iosif; Marin, Catalin-Nicolae; Koos, Marie-Jeanne; Jelicic, Biljana; Milutinovic, Vuk
2015-12-01
Dry eye syndrome is characterized by eye irritation due to changes of the tear film. Symptoms include itching, foreign body sensations, mucous discharge and transitory vision blurring. Less occurring symptoms include photophobia and eye tiredness. Aim of the work was to determine the quality of the tear film and ocular dryness potential risk in persons who spend more than 8 hours using computers and possible correlations between severity of symptoms (dry eyes symptoms anamnesis) and clinical signs assessed by: Schirmer test I, TBUT (Tears break-up time), TFT (Tear ferning test). The results show that subjects using computer have significantly shorter TBUT (less than 5 s for 56 % of subjects and less than 10 s for 37 % of subjects), TFT type II/III in 50 % of subjects and type III 31% of subjects was found when compared to computer non users (TFT type I and II was present in 85,71% of subjects). Visual display terminal use, more than 8 hours daily, has been identified as a significant risk factor for dry eye. It's been advised to all persons who spend substantial time using computers to use artificial tears drops in order to minimize the symptoms of dry eyes syndrome and prevents serious complications.
Effects of diquafosol sodium eye drops on tear film stability in short BUT type of dry eye.
Shimazaki-Den, Seika; Iseda, Hiroyuki; Dogru, Murat; Shimazaki, Jun
2013-08-01
To investigate the effects of diquafosol sodium (DQS) eye drops, a purinergic P2Y2 receptor agonist, on tear film stability in patients with unstable tear film (UTF). Two prospective studies were conducted. One was an exploratory nonrandomized trial on 39 eyes with dry eye symptoms and short tear film break-up time (BUT), but without epithelial damage. Changes in symptoms, BUT, Schirmer value, and ocular surface fluorescein staining (FS) scores were studied for 3 months. The other was a randomized clinical trial of DQS and artificial tears (AT) in 17 eyes with short BUT. Eyes with decreased Schirmer values (≤ 5 mm) were excluded. Changes in symptoms, BUT, FS scores, and tear film stability using continuous corneal topographic analysis were studied for 4 weeks. In the exploratory study, while Schirmer values were not significantly increased, significant improvements in symptoms and BUT were noted at both 1 and 3 months. In the randomized clinical trial, significant improvements in symptoms were noted in the DQS group, but not in the AT group, at 2 weeks. BUT was significantly prolonged in the DQS group at 4 weeks but not in the AT group. No significant changes were noted in FS scores or tear film stability. DQS improved subjective symptoms and prolonged BUT in eyes with UTF not associated with low tear secretion and ocular surface epithelial damage. Because many patients who have UTF are refractory to conventional treatments, DQS may offer benefits in the treatment of dry eyes.
21 CFR 876.5830 - Hemodialyzer with disposable insert (Kiil type).
Code of Federal Regulations, 2010 CFR
2010-04-01
... Hemodialyzer with disposable insert (Kiil type). (a) Identification. A hemodialyzer with disposable inserts (Kiil type) is a device that is used as a part of an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that includes disposable inserts consisting of layers...
... and saliva. This causes a dry mouth and dry eyes. You may have dryness in other places that ... affected. It may include artificial tears for dye eyes and sucking on sugar-free candy or drinking water often for a dry mouth. Medicines may help with severe symptoms. NIH: ...
Effects of punctal occlusion on global tear proteins in patients with dry eye.
Tong, Louis; Zhou, Lei; Beuerman, Roger; Simonyi, Susan; Hollander, David A; Stern, Michael E
2017-10-01
To investigate effects of punctal occlusion on global tear protein levels in patients with dry eye. In this prospective, longitudinal, single-center study, nonabsorbable punctal plugs were inserted bilaterally into the lower punctum of 30 patients with moderate dry eye. Dry eye symptoms, fluorescein corneal staining, Schirmer I test, tear film break-up time, and safety were assessed in the more severely affected eye. Tear proteins at weeks 1 and 3 were quantified by iTRAQ relative to baseline preocclusion levels. Of 29 patients who completed the study, 23 (mean age 49.8 years) had sufficient tear samples for analysis. After 3 weeks, punctal occlusion significantly upregulated tear proteins, including glutathione synthase (mean of 1.6-fold, P = 0.01) and interleukin-1 receptor antagonist (1.7-fold, P = 0.032) and downregulated cholinergic receptor (neuronal) alpha-7 (0.79-fold, P = 0.039) and lymphocyte cytosolic protein-1 (0.66-fold, P = 0.012). Clustering analysis of global tear proteins revealed two clear profile changes; the first group of patients (cluster 1, n = 10) had a reduction in the inflammatory proteins (e.g., S100A8) and rise in lacrimal proteins supporting the ocular surface (e.g., lysozyme), whereas the second group (cluster 2, n = 13) had an increase in inflammatory proteins and a decrease in lacrimal proteins. Logistic regression analysis revealed that cluster 1 patients had significantly (P = 0.006) lower Schirmer scores at baseline (mean [standard deviation]: 4.3 [4.3] mm) than cluster 2 (6.8 [2.6] mm). Punctal plugs produced a beneficial pattern of tear protein change in patients with relatively low Schirmer scores within 3 weeks of punctal occlusion. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Tear fluid collection in dogs and cats using ophthalmic sponges.
Sebbag, Lionel; Harrington, Danielle M; Mochel, Jonathan P
2018-05-01
To compare the use of two ophthalmic sponges for tear collection in dogs and cats. Ten healthy dogs and 10 healthy cats. A strip (4 × 10 mm) of either cellulose or polyvinyl acetal (PVA) sponge was inserted into the ventral fornix of each eye for either 15, 30, or 60 s. The wetted strip was placed into a 0.2-mL tube that was first punctured at its bottom. Tears were eluted through the drainage hole into a 1.5-mL tube via centrifugation. Tear volume absorbed (VA) and tear volume recovered (VR) were calculated as the difference of the post- and precollection weight of the 0.2-mL tube and 1.5-mL tube, respectively. Recovery ratio (RR) was determined as the ratio between VR and VA. Ophthalmic sponges were well tolerated by all subjects. In dogs and cats, median (95% range) VA, VR, and RR were as follows: 44 μL (11-106 μL) and 16 μL (2-43 μL); 27 μL (1-84 μL) and 6 μL (0-29 μL); 64% (7-91%) and 35% (0-86%), respectively. PVA sponges achieved significantly greater VR in cats and RR in both species. All parameters were significantly greater with a collection time of 60 vs. 30 and 15 s. Body weight was associated with VA and VR in dogs but not cats. Polyvinyl acetal is better than cellulose for tear collection given its superior recovery. Ophthalmic sponges could facilitate routine analysis of tear fluid in dogs and cats, although further studies are needed to evaluate the quality of tears obtained with this method. © 2017 American College of Veterinary Ophthalmologists.
Can artificial tears prevent Acanthamoeba keratitis? An in vitro approach.
Magnet, Angela; Gomes, Thiago Santos; Pardinas, Carmen; Garcia de Blas, Natalia; Sadaba, Cruz; Carrillo, Eugenia; Izquierdo, Fernando; Del Castillo, José Manuel Benítez; Hurtado, Carolina; Del Aguila, Carmen; Fenoy, Soledad
2018-01-22
The use of contact lenses has increased in recent years as has the incidence of Dry Eye Syndrome, partly due to their use. Artificial tears are the most common treatment option. Since these changes can facilitate Acanthamoeba infection, the present study has been designed to evaluate the effect of three artificial tears treatments in the viability of Acanthamoeba genotype T4 trophozoites. Optava Fusion™, Oculotect®, and Artelac® Splash were selected due to their formulation. Viability was assessed using two staining methods, Trypan Blue stain and CTC stain at different time intervals (2, 4, 6, 8 and 24 h). Trypan Blue viability was obtained by manual count with light microscopy while the CTC stain was determined using flow cytometry. Trypan Blue staining results demonstrated a decrease in viability for Optava Fusion™ and Artelac® Splash during the first 4 h of incubation. After, this effect seems to lose strength. In the case of Oculotect®, complete cell death was observed after 2 h. Using flow cytometry analysis, Optava Fusion™ and Oculotect® exhibited the same effect observed with Trypan Blue staining. However, Artelac® Splash revealed decreasing cell respiratory activity after four hours, with no damage to the cell membrane. The present study uses, for the first time, CTC stain analyzed by flow cytometry to establish Acanthamoeba viability demonstrating its usefulness and complementarity with the traditional stain, Trypan Blue. Artelac® Splash, with no preservatives, and Optava Fusion TM, with Purite®, have not shown any useful amoebicidal activity. On the contrary, promising results presented by Ocultect®, with BAK, open up a new possibility for Acanthamoeba keratitis prophylaxis and treatment although in vivo studies should be carried out.
Reviglio, Victor E; Rana, Tayyib S; Li, Qian J; Ashraf, M Farooq; Daly, Mary K; O'Brien, Terrence P
2003-05-01
To assess the effects of nonsteroidal antiinflammatory drug (NSAID) eyedrops on the expression of matrix metalloproteinases in corneal tissue. Ocular Microbiology and Immunology Laboratory, Refractive Surgery Research Laboratory, The Wilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA. Seventy rats were divided into 2 groups: intact and debrided epithelium. Uniform central corneal epithelial defects were created in the right eye of the debrided corneal group. Each group was divided into 4 subgroups, each receiving 1 of the following eyedrops or artificial tears: The 3 NSAIDs were diclofenac sodium 0.1% (Falcon or Voltaren) and preservative-free ketorolac 0.5% (Acular PF). The artificial tears were carboxymethylcellulose sodium 0.5% (Refresh Plus PF). The eyedrops were administered 4 times a day for 1 week. The rats were killed on days 2 and 7. The corneas were excised and processed for immunohistochemical staining, Western blot assay, and zymography studies to determine the localization of the production of the following matrix metalloproteinases (MMPs): MMP-1, MMP-2, MMP-8, and MMP-9. Matrix metalloproteinase-1, MMP-8, and MMP-2 were detected in rat corneas at 48 hours in the debrided and intact epithelium groups treated with NSAID eyedrops. The MMP-1 and MMP-8 expression levels were higher in intact corneas in the diclofenac sodium groups than in the ketorolac and artificial tears groups. The expression was localized mostly in the epithelial cells and occasionally in keratocytes. This study provides preliminary evidence that topical application of some NSAIDs can induce the early expression of MMP-1, MMP-2, and MMP-8 in the cornea, suggesting that MMPs play a role in the corneal cytotoxicity of certain NSAIDs.
Chen, Tinggui; Xiao, Renbin
2014-01-01
Due to fierce market competition, how to improve product quality and reduce development cost determines the core competitiveness of enterprises. However, design iteration generally causes increases of product cost and delays of development time as well, so how to identify and model couplings among tasks in product design and development has become an important issue for enterprises to settle. In this paper, the shortcomings existing in WTM model are discussed and tearing approach as well as inner iteration method is used to complement the classic WTM model. In addition, the ABC algorithm is also introduced to find out the optimal decoupling schemes. In this paper, firstly, tearing approach and inner iteration method are analyzed for solving coupled sets. Secondly, a hybrid iteration model combining these two technologies is set up. Thirdly, a high-performance swarm intelligence algorithm, artificial bee colony, is adopted to realize problem-solving. Finally, an engineering design of a chemical processing system is given in order to verify its reasonability and effectiveness.
Biomechanical Cadaveric Evaluation of Partial Acute Peroneal Tendon Tears.
Wagner, Emilio; Wagner, Pablo; Ortiz, Cristian; Radkievich, Ruben; Palma, Felipe; Guzmán-Venegas, Rodrigo
2018-06-01
No clear guideline or solid evidence exists for peroneal tendon tears to determine when to repair, resect, or perform a tenodesis on the damaged tendon. The objective of this study was to analyze the mechanical behavior of cadaveric peroneal tendons artificially damaged and tested in a cyclic and failure mode. The hypothesis was that no failure would be observed in the cyclic phase. Eight cadaveric long leg specimens were tested on a specially designed frame. A longitudinal full thickness tendon defect was created, 3 cm in length, behind the tip of the fibula, compromising 66% of the visible width of the peroneal tendons. Cyclic testing was initially performed between 50 and 200 N, followed by a load-to-failure test. Tendon elongation and load to rupture were measured. No tendon failed or lengthened during cyclic testing. The mean load to failure for peroneus brevis was 416 N (95% confidence interval, 351-481 N) and for the peroneus longus was 723 N (95% confidence interval, 578-868 N). All failures were at the level of the defect created. In a cadaveric model of peroneal tendon tears, 33% of remaining peroneal tendon could resist high tensile forces, above the physiologic threshold. Some peroneal tendon tears can be treated conservatively without risking spontaneous ruptures. When surgically treating a symptomatic peroneal tendon tear, increased efforts may be undertaken to repair tears previously considered irreparable.
Forkel, Philipp; Herbort, Mirco; Schulze, Martin; Rosenbaum, Dieter; Kirstein, Lars; Raschke, Michael; Petersen, Wolf
2013-05-01
The purpose of this study was to evaluate the effects of different types of lateral meniscus root tears in terms of tibiofemoral contact stress. Ten porcine knees each underwent five different testing conditions with the menisci intact, a simulated lateral posterior root tear with and without cutting the meniscofemoral ligament and with an artificial tear of the posterior root of the medial meniscus. Biomechanical testing was performed at 30° of flexion with an axial load of 100 N. A pressure sensor (st Sensor Type S2042, Novel, Munich) was used to measure the tibiofemoral contact area and the tibiofemoral contact pressure. Data were analyzed to assess the differences in contact area and tibiofemoral peak contact pressure among the five meniscal conditions. There was no significant difference in mean contact pressure between the state with the menisci intact and an isolated posterior root tear of the lateral meniscus. In case of a root tear and a tear of the meniscofemoral ligament, the contact area decreased in comparison with the intact state of the menisci. After additional cutting of the meniscofemoral ligament, the tibiofemoral contact pressure was significantly higher in comparison with the intact state and the avulsion injury. In the medial compartment, joint compression forces were significantly increased in comparison with the intact state after cutting the posterior root of the medial meniscus (P < 0.05). The consequence of a medial meniscus root tear is well known and was verified by this analysis. The results of the present study show that the biomechanical consequences of a lateral meniscus root tear depend on the state of the meniscofemoral ligament. An increase in tibiofemoral contact pressure is only to be expected in combined injuries of the meniscus root and the meniscofemoral ligaments. Posterior lateral meniscus root tear might have a better prognosis in terms of the development of osteoarthritis when the meniscofemoral ligament is intact.
Gatell-Tortajada, Jordi
2016-01-01
To assess the benefits and tolerability of a dietary supplement based on omega-3 fatty acids to relieve dry eye symptoms. A total of 1,419 patients (74.3% women, mean age 58.9 years) with dry eye syndrome using artificial tears participated in a 12-week prospective study. Patients were instructed to take 3 capsules/day of the nutraceutical formulation (Brudysec(®) 1.5 g). Study variables were dry eye symptoms (scratchy and stinging sensation, eye redness, grittiness, painful and tired eyes, grating sensation, and blurry vision), conjunctival hyperemia, tear breakup time (TBUT), Schrimer I test, and Oxford grading scheme. At 12 weeks, each dry eye symptom improved significantly (P<0.001), and the use of artificial tears decreased significantly from 3.77 (standard deviation [SD] =2.08) at baseline to 3.45 (SD =1.72) (P<0.01). In addition, the Schirmer test scores and the TBUT increased significantly, and there was an increase in patients grading 0-I in the Oxford scale and a decrease of those grading IV-V. Significant differences in improvements of dry eye symptoms were also found in compliant versus noncompliant patients as well as in those with moderate/severe versus none/mild conjunctival hyperemia. Oral ω-3 fatty acids supplementation was an effective treatment for dry eye symptoms.
Perceptions of dry eye disease management in current clinical practice.
Williamson, Jennifer F; Huynh, Kyle; Weaver, Mark A; Davis, Richard M
2014-03-01
To assess the perceptions of eye care providers regarding the clinical management of dry eye. Invitations to complete a 17-question online survey were mailed to 400 members of the North Carolina Ophthalmology and Optometry Associations including community optometrists, comprehensive ophthalmologists, and cornea specialists. The survey was completed by 100 eye care providers (25% response rate). Providers reported burning (46.5%) as the most frequent symptom described by patients, followed by foreign body sensation (30.3%) and tearing (17.2%). Most respondents (80.8%) listed artificial tears as the recommended first-line treatment, even though providers reported high failure rates for both artificial tears and cyclosporine A (Restasis). Rheumatoid arthritis, Sjögren syndrome, affective disorders such as anxiety and depression, history of photorefractive surgery, smoking, and thyroid disease were acknowledged as common comorbid conditions. The survey provided an informative snapshot into the preferences of eye care providers concerning the diagnosis and management of dry eye disease. Overall, burning was the most common symptom reported by patients. Providers relied more on patient history in guiding their clinical decisions than objective signs. The survey underscores the incongruence when comparing subjective symptoms with objective signs, thereby highlighting the urgent need for the development of reliable metrics to better quantify dry eye symptoms and also the development of a more sensitive and specific test that can be used as the gold standard to diagnose dry eye.
Effect of chitosan-N-acetylcysteine conjugate in a mouse model of botulinum toxin B-induced dry eye.
Hongyok, Teeravee; Chae, Jemin J; Shin, Young Joo; Na, Daero; Li, Li; Chuck, Roy S
2009-04-01
To evaluate the effect of a thiolated polymer lubricant, chitosan-N-acetylcysteine conjugate (C-NAC), in a mouse model of dry eye. Eye drops containing 0.5% C-NAC, 0.3% C-NAC, a vehicle (control group), artificial tears, or fluorometholone were applied in a masked fashion in a mouse model of induced dry eye from 3 days to 4 weeks after botulinum toxin B injection. Corneal fluorescein staining was periodically recorded. Real-time reverse transcriptase-polymerase chain reaction and immunofluorescence staining were performed at the end of the study to evaluate inflammatory cytokine expressions. Mice treated with C-NAC, 0.5%, and fluorometholone showed a downward trend that was not statistically significant in corneal staining compared with the other groups. Chitosan-NAC formulations, fluorometholone, and artificial tears significantly decreased IL-1beta (interleukin 1beta), IL-10, IL-12alpha, and tumor necrosis factor alpha expression in ocular surface tissues. The botulinum toxin B-induced dry eye mouse model is potentially useful in evaluating new dry eye treatment. Evaluation of important molecular biomarkers suggests that C-NAC may impart some protective ocular surface properties. However, clinical data did not indicate statistically significant improvement of tear production and corneal staining in any of the groups tested. Topically applied C-NAC might protect the ocular surface in dry eye syndrome, as evidenced by decreased inflammatory cytokine expression.
Cytokine changes in tears and relationship to contact lens discomfort
Zhao, Zhenjun; Naduvilath, Thomas; Lazon de la Jara, Percy
2015-01-01
Purpose To determine the reproducibility of a multiplex bead assay for measuring cytokines in tears and correlations between ocular discomfort with or without contact lens wear and the concentration of cytokines in tears. Methods Ninety participants (divided into two groups) were enrolled in this prospective study. They were asked to rate their ocular comfort and collect their tears in the morning and just before sleep for 10 days with or without contact lenses. The participants collected their tears using a glass microcapillary tube for both stages. Galyfilcon A lenses were worn on a daily disposable basis during the contact lens stage, and comfort scores and tears were collected before lens insertion and prior to lens removal at the end of the day. Tears were analyzed for cytokine concentrations using a 27-plex multibead assay. Correlations were sought between cytokine concentrations and comfort. Results There was a significant (p<0.022) decrease in ocular comfort over the day with or without lens wear. The magnitude of ocular discomfort was significantly greater (p<0.009) with lens wear. The concentrations of 12 cytokines differed significantly between the groups; thus, these cytokines were not analyzed further. For the remaining 15 cytokines, interleukin-8 (IL-8) was the only cytokine that changed in both groups during the day without (reduced by >-0.5 Log pg/ml, p<0.001) or with lens wear (reduced by >-0.2 Log pg/ml, p<0.001). The change in the vascular endothelial growth factor (VEGF) concentration only in tears was correlated to ocular comfort, but this was not changed by contact lens wear. Conclusions Ocular comfort during the day is magnified by contact lens wear. However, the increase in the change in comfort during lens wear was not associated with changes in 15 cytokines in the tear film. PMID:25814827
Semeraro, Francesco; Forbice, Eliana; Nascimbeni, Giuseppe; Taglietti, Marco; Romano, Vito; Guerra, Germano; Costagliola, Ciro
To evaluate in vivo changes after therapy using autologous serum (AS) eye drops in Sjögren's syndrome (SS)-related dry eyes by confocal microscopy. In this study, 24 patients with SS-related dry eyes [12 in AS eye drop therapy and 12 in artificial tear (AT) therapy] and 24 healthy volunteers were recruited. Ocular Surface Disease Index (OSDI), central corneal thickness, tear film, break-up time, corneal and conjunctival staining, Schirmer's test and corneal confocal microscopy were investigated. Tear production, tear stability, corneal staining, inflammation, and central corneal thickness, Langherans cells, activated keratocytes, intermediate epithelial cell density, nerve tortuosity, number of sub-basal nerve branches, and number of bead-like formations differed between patients and controls (p<0.0001). The AT and AS groups differed in the OSDI, number of branches, and number of beadings (p<0.0001). AS eye drops improve symptoms and confocal microscopy findings in SS-related dry eyes. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Huang, Jehn-Yu; Yeh, Po-Ting; Hou, Yu-Chih
2016-01-01
To evaluate the efficacy of oral antioxidant supplementation in the treatment of patients with dry eye syndrome (DES). A prospective, randomized, double-blinded study compared the effects of an antioxidant supplement (containing anthocyanosides, astaxanthin, vitamins A, C, and E, and several herbal extracts, including Cassiae semen and Ophiopogonis japonicus) with placebo on patients with DES. We assessed dry eye symptoms, visual acuity, Schirmer's test, tear film breakup time, cornea and conjunctiva fluorescein staining, serum anti-SSA/anti-SSB antibodies, and the level of reactive oxygen species (ROS) in tears. The supplementation period was 8 weeks and patients were followed up every 4 weeks for 16 weeks. A linear mixed model was used to compare the groups, while within-group differences were tested by repeated-measures analysis of variance. Forty-three patients, 20 and 23 in treatment and placebo groups, respectively, completed the study. Liver and renal functions were normal. Diastolic blood pressure decreased in the treatment group. There were no significant differences in systolic blood pressure, dry eye symptoms, serum anti-SSA and anti-SSB, visual acuity, intraocular pressure, or fluorescein corneal staining between the groups. Tear film breakup time scores and Schirmer's test without topical anesthesia significantly improved in the treatment group. Tear ROS level differed between the groups and decreased after treatment. Overall subjective impression revealed a significant improvement with treatment compared with placebo. Oral antioxidant supplementations may increase tear production and improve tear film stability by reducing tear ROS. The vegetable-based antioxidant supplement used in this study is safe and can be utilized as an adjuvant therapy to conventional artificial tear therapy for patients with DES.
Wear and Tear of Tyres: A Stealthy Source of Microplastics in the Environment
Kole, Pieter Jan; Löhr, Ansje J.; Van Belleghem, Frank G. A. J.; Ragas, Ad M. J.
2017-01-01
Wear and tear from tyres significantly contributes to the flow of (micro-)plastics into the environment. This paper compiles the fragmented knowledge on tyre wear and tear characteristics, amounts of particles emitted, pathways in the environment, and the possible effects on humans. The estimated per capita emission ranges from 0.23 to 4.7 kg/year, with a global average of 0.81 kg/year. The emissions from car tyres (100%) are substantially higher than those of other sources of microplastics, e.g., airplane tyres (2%), artificial turf (12–50%), brake wear (8%) and road markings (5%). Emissions and pathways depend on local factors like road type or sewage systems. The relative contribution of tyre wear and tear to the total global amount of plastics ending up in our oceans is estimated to be 5–10%. In air, 3–7% of the particulate matter (PM2.5) is estimated to consist of tyre wear and tear, indicating that it may contribute to the global health burden of air pollution which has been projected by the World Health Organization (WHO) at 3 million deaths in 2012. The wear and tear also enters our food chain, but further research is needed to assess human health risks. It is concluded here that tyre wear and tear is a stealthy source of microplastics in our environment, which can only be addressed effectively if awareness increases, knowledge gaps on quantities and effects are being closed, and creative technical solutions are being sought. This requires a global effort from all stakeholders; consumers, regulators, industry and researchers alike. PMID:29053641
Wear and Tear of Tyres: A Stealthy Source of Microplastics in the Environment.
Kole, Pieter Jan; Löhr, Ansje J; Van Belleghem, Frank G A J; Ragas, Ad M J
2017-10-20
Wear and tear from tyres significantly contributes to the flow of (micro-)plastics into the environment. This paper compiles the fragmented knowledge on tyre wear and tear characteristics, amounts of particles emitted, pathways in the environment, and the possible effects on humans. The estimated per capita emission ranges from 0.23 to 4.7 kg/year, with a global average of 0.81 kg/year. The emissions from car tyres (100%) are substantially higher than those of other sources of microplastics, e.g., airplane tyres (2%), artificial turf (12-50%), brake wear (8%) and road markings (5%). Emissions and pathways depend on local factors like road type or sewage systems. The relative contribution of tyre wear and tear to the total global amount of plastics ending up in our oceans is estimated to be 5-10%. In air, 3-7% of the particulate matter (PM 2.5 ) is estimated to consist of tyre wear and tear, indicating that it may contribute to the global health burden of air pollution which has been projected by the World Health Organization (WHO) at 3 million deaths in 2012. The wear and tear also enters our food chain, but further research is needed to assess human health risks. It is concluded here that tyre wear and tear is a stealthy source of microplastics in our environment, which can only be addressed effectively if awareness increases, knowledge gaps on quantities and effects are being closed, and creative technical solutions are being sought. This requires a global effort from all stakeholders; consumers, regulators, industry and researchers alike.
2011-01-01
Background We herein describe a surgical technique for the repair of complete tear of the pectoralis major (PM) tendon using endobuttons to strengthen initial fixation. Methods Five male patients (3 judo players, 1 martial arts player, and 1 body builder) were treated within 2 weeks of sustaining complete tear of the PM tendon. Average age at surgery and follow-up period were 28.4 years (range, 23-33) and 28.8 months (range, 24-36). A rectangular bone trough (about 1 × 4 cm) was created on the humerus at the insertion of the distal PM tendon. The tendon stump was introduced into this trough, and fixed to the reverse side of the humeral cortex using endobuttons and non-absorbable suture. Clinical assessment of re-tear was examined by MRI. Shoulder range of motion (ROM), outcome of treatment, and isometric power were measured at final follow-up. Results There were no clinical re-tears, and MRI findings also showed continuity of the PM tendon in all cases at final follow-up. Average ROM did not differ significantly between the affected and unaffected shoulders. The clinical outcomes at final follow-up were excellent (4/5 cases) or good (1/5). In addition, postoperative isometric power in horizontal flexion of the affected shoulder showed complete recovery when compared with the unaffected side. Conclusions Satisfactory outcomes could be obtained when surgery using the endobutton technique was performed within 2 weeks after complete tear of the PM tendon. Therefore, our new technique appears promising as a useful method to treat complete tear of the PM tendon. PMID:21955511
Hori, Yuichi; Kageyama, Tomofumi; Sakamoto, Asuka; Shiba, Tomoaki; Nakamura, Masatsugu; Maeno, Takatoshi
To investigate the short-term effects of 2 new secretagogue eye drops for dry eye, 3% diquafosol tetrasodium ophthalmic solution (diquafosol) and 2% rebamipide ophthalmic suspension (rebamipide), on the concentration of mucin 5AC (MUC5AC) in rabbit tear fluid and conjunctival goblet cells. One dose of artificial tears, diquafosol or rebamipide, was instilled into 8 eyes of Japanese white rabbits. MUC5AC concentration in the tear fluid was examined using the enzyme-linked immunosorbent assay 15 min after instillation and compared with 8 untreated controls. Impression cytology was performed to measure the number of periodic acid Schiff (PAS)-positive cells and the ratio of the PAS-positive area using image analysis software. Statistical comparison was performed using ANOVA with post hoc analysis with the Tukey's test. After 15 min, only diquafosol significantly (P ≤ 0.01) increased the MUC5AC level in the tear fluid. Although no drug affected the number of PAS-positive cells, the ratio of the PAS-positive area decreased significantly (P ≤ 0.01) only in the diquafosol group. These data indicated that more PAS-positive MUC5AC was released into the tear fluid from the goblet cells by diquafosol than by rebamipide. There is a difference in the induction pattern of MUC5AC into the tears from the goblet cells between these eye drops.
Tseng, Ching-Li; Hung, Ya-Jung; Chen, Zhi-Yu; Fang, Hsu-Wei; Chen, Ko-Hua
2016-01-01
Dry eye syndrome (DES) is a common eye disease. Artificial tears (AT) are used to treat DES, but they are not effective. In this study, we assessed the anti-inflammatory effect of AT containing epigallocatechin gallate (EGCG) and hyaluronic acid (HA) on DES. Human corneal epithelial cells (HCECs) were used in the WST-8 assay to determine the safe dose of EGCG. Lipopolysaccharide-stimulated HCECs showing inflammation were treated with EGCG/HA. The expression of IL-1ß, IL-6, IL-8, and TNF-α was assessed by real-time PCR and AT physical properties such as the viscosity, osmolarity, and pH were examined. AT containing EGCG and HA were topically administered in a rabbit DES model established by treatment with 0.1% benzalkonium chloride (BAC). Tear secretion was assessed and fluorescein, H&E, and TUNEL staining were performed. Inflammatory cytokine levels in the corneas were also examined. The non-toxic optimal concentration of EGCG used for the treatment of HCECs in vitro was 10 μg/mL. The expression of several inflammatory genes, including IL-1ß, IL-6, IL-8, and TNF-α, was significantly inhibited in inflamed HCECs treated with 10 μg/mL EGCG and 0.1% (w/v) HA (E10/HA) compared to that in inflamed HCECs treated with either EGCG or HA alone. AT containing E10/HA mimic human tears, with similar osmolarity and viscosity and a neutral pH. Fluorescence examination of the ocular surface of mouse eyes showed that HA increased drug retention on the ocular surface. Topical treatment of DES rabbits with AT plus E10/HA increased tear secretion, reduced corneal epithelial damage, and maintained the epithelial layers and stromal structure. Moreover, the corneas of the E10/HA-treated rabbits showed fewer apoptotic cells, lower inflammation, and decreased IL-6, IL-8, and TNF-α levels. In conclusion, we showed that AT plus E10/HA had anti-inflammatory and mucoadhesive properties when used as topical eye drops and were effective for treating DES in rabbits.
Robert G. Hooper; William E. Taylor; Susan C. Loeb
2004-01-01
Between 1990 and 1992 an extensive artificial cavity installation program was conducted on the Francis Marion National Forest (FMNF) in coastal South Carolina where Hurricane Hugo had caused vast devastation. Four artificial cavity types were installed: drilled starts, drilled cavities, modified drilled cavities, and inserts. In 1998, we examined 443 of the artificial...
2014-01-01
Due to fierce market competition, how to improve product quality and reduce development cost determines the core competitiveness of enterprises. However, design iteration generally causes increases of product cost and delays of development time as well, so how to identify and model couplings among tasks in product design and development has become an important issue for enterprises to settle. In this paper, the shortcomings existing in WTM model are discussed and tearing approach as well as inner iteration method is used to complement the classic WTM model. In addition, the ABC algorithm is also introduced to find out the optimal decoupling schemes. In this paper, firstly, tearing approach and inner iteration method are analyzed for solving coupled sets. Secondly, a hybrid iteration model combining these two technologies is set up. Thirdly, a high-performance swarm intelligence algorithm, artificial bee colony, is adopted to realize problem-solving. Finally, an engineering design of a chemical processing system is given in order to verify its reasonability and effectiveness. PMID:25431584
Ozen, Serkan; Ozer, Murat Atabey; Akdemir, Mehmet Orçun
2017-06-01
This study aims to understand the effect of vitamin B12 deficiency on neuropathic ocular pain (NOP) and symptoms in patients with dry eye disease (DED). Patients with severe DED (without receiving topical artificial tears treatment) and ocular pain were enrolled (n = 90). Patients with severe DED and vitamin B12 deficiency (group 1, n = 45) received parenteral vitamin B12 supplement + topical treatment (artificial tears treatment + cyclosporine), and patients with severe DED and normal serum vitamin B12 level (group 2, n = 45) received only topical treatment (artificial tears treatment + cyclosporine). Patients were evaluated by the ocular surface disease index (OSDI) questionnaire, 3rd question (have you experienced painful or sore eyes during last week?) score of OSDI as a pain determiner and pain frequency measure), tear break up time (TBUT), and Schirmer's type 1 test. We compared the groups' OSDI, TBUT, and Schirmer's test recordings at the first visit and after 12 weeks retrospectively. The OSDI score, 3rd OSDI question score, TBUT, and Schirmer's test results improved after 12 weeks (p < 0.001 for each group). The mean vitamin B12 level at enrollment was 144.24 ±43.36 pg/ml in group 1 and 417.53 ±87.22 pg/ml in group 2. The mean vitamin B12 level in group 1 reached to 450 ±60.563 pg/ml after 12 weeks of treatment. The mean score changes between the groups were not statistically significant; however, the decrease in the OSDI questionnaire score (-30.80 ±5.24) and 3rd OSDI question score (-2.82 ±0.53) were remarkable in group 1 (Table 2). The mean TBUT increase was +7.98 ±2.90 s and Schirmer's test result increase was +12.16 ±2.01 mm in group 1. The mean TBUT increase was +6.18 ±1.49 s and Schirmer's test result increase was +6.71 ±1.47 mm in group 2. These findings indicate that vitamin B12 deficiency is related with NOP. It may be important to consider measuring the serum vitamin B12 level in patients with severe DED presenting with resistant ocular pain despite taking topical treatment.
Thermographic and microscopic evaluation of LARS knee ligament tearing.
Pătraşcu, Jenel Marian; Amarandei, Mihaela; Kun, Karla Noemy; Borugă, Ovidiu; Totorean, Alina; Andor, Bogdan; Florescu, Sorin
2014-01-01
Damage to knee articular ligaments causes important functional problems and adversely affects particularly the stability of the knee joint. Several methods were developed in order to repair damage to the anterior cruciate ligament (ACL), which employ autografts, allografts, as well as synthetic ligaments. One such synthetic scaffold, the ligament advanced reinforcement system (LARS) synthetic ligament is made of non-absorbing polyethylene terephthalate fibers whose structure allow tissue ingrowths in the intra-articular part, improving the stability of the joint. The LARS ligament is nowadays widely used in modern knee surgery in the Europe, Canada, China or Japan. This paper evaluates LARS ligament from two perspectives. The first regards a study done by the Orthopedics Clinic II, Timisoara, Romania, which compared results obtained by employing two techniques of ACL repair - the Bone-Tendon-Bone (BTB) or LARS arthroscopic, intra-articular techniques. This study found that patients treated with the BTB technique presented with an IKDC score of 45.82±1.14 units preoperative, with increasing values in the first nine months after each implant post-surgical ligament restoration, reaching an average value of 75.92 ± 2.88 units postoperative. Patients treated with the LARS technique presented with an IKDC score of 43.64 ± 1.11 units preoperative, and a score of 77.32 ± 2.71 units postoperative. The second perspective describes the thermographic and microscopic analysis of an artificial knee ligament tearing or loosening. The objective of the study was to obtain information regarding the design of artificial ligaments in order to expand their lifespan and avoid complications such as recurring synovitis, osteoarthritis and trauma of the knee joint. Thermographic data has shown that tearing begins from the inside out, thus improving the inner design of the ligament would probably enhance its durability. An optical microscope was employed to obtain images of structural damage in the inner layers, for use in further analysis of the tears. In conclusion, the LARS artificial ligament, like the BTB technique, displays both advantages and disadvantages. It is important to understand that these two options of ACL lesion repair are not competing. LARS could, in addition to its use in primary ACL ruptures, be utilized in revisions of autologous graft rupture post primary ACL repair.
In-vitro analysis of the microbicidal activity of 6 contact lens care solutions
2012-01-01
Background Contact lens-related infections are often associated with inadequate contact lens hygiene, and therefore, contact lens care products should be able to sufficiently minimise the amount of pathogens that are responsible for these infections. In 2001, the EN ISO 14729 was introduced to ensure adequate disinfection efficacy of contact lens care solutions, but this norm has recently been criticised. Methods In this study, six frequently used contact lens care solutions were retested according to the Stand Alone Test of the EN ISO 14729 (2001). The Stand Alone Test is a quantitative suspension test. In addition, the products were tested in a modified setting adding an organic load. The load was a mixture of human blood serum, lysozyme, and mucine, which resembles tear fluid. Results The criteria of the Stand Alone Test recommended in EN ISO 14729 were only met by Aosept Plus. This 3% hydrogen-peroxide-based contact lens care solution attained a reduction factor of > 5 log units for bacteria and > 4 for fungi in all cases. Two further contact lens care solutions, Blue Vision and Optifree Replenish, met the criteria of a reduction factor of > 3 log units for bacteria and > 1 log unit for fungi, but only in the presence of artificial tear fluid. The three remaining products did not exhibit adequate disinfecting efficacy, at least against one of the tested microorganisms. Conclusions Through the observation that the artificial tear fluid used in this study influences the disinfecting efficacy of contact lens care solutions, especially that of multi-purpose solutions, in a different way than does albumin, mucine, or even the organic load suggested in EN ISO 14729, it becomes obvious that the test conditions in the EN ISO 14729 should be revised in order to create more realistic conditions, e.g., by using a more realistic artificial tear fluid. Furthermore, we suggest adapting the EN ISO 14729 to the European test hierarchy for chemical disinfectants and antiseptics, which consists of three test phases and also requests meeting stricter criteria in order to pass the test. Unless the test conditions guarantee a sufficient reduction of potential pathogens, the risk of contact lens-related microbial keratitis and other infections will remain for the users. PMID:23033880
Active role of a human genomic insert in replication of a yeast artificial chromosome.
van Brabant, A J; Fangman, W L; Brewer, B J
1999-06-01
Yeast artificial chromosomes (YACs) are a common tool for cloning eukaryotic DNA. The manner by which large pieces of foreign DNA are assimilated by yeast cells into a functional chromosome is poorly understood, as is the reason why some of them are stably maintained and some are not. We examined the replication of a stable YAC containing a 240-kb insert of DNA from the human T-cell receptor beta locus. The human insert contains multiple sites that serve as origins of replication. The activity of these origins appears to require the yeast ARS consensus sequence and, as with yeast origins, additional flanking sequences. In addition, the origins in the human insert exhibit a spacing, a range of activation efficiencies, and a variation in times of activation during S phase similar to those found for normal yeast chromosomes. We propose that an appropriate combination of replication origin density, activation times, and initiation efficiencies is necessary for the successful maintenance of YAC inserts.
Imaging of plantar fascia and Achilles injuries undertaken at the London 2012 Olympics.
Elias, David A; Carne, Andrew; Bethapudi, Sarath; Engebretsen, Lars; Budgett, Richard; O'Connor, Philip
2013-12-01
Plantar fascia and distal Achilles injuries are common in elite athletes. Acute athletic injuries of the plantar fascia include acute plantar fasciopathy and partial or complete tears. Underlying most acute injuries is a background of underlying chronic plantar fasciopathy. Injuries may affect the central or less commonly lateral portions of the fascia and acute tears are generally proximal. Athletic Achilles injuries may occur at the mid tendon or the distal insertion, and there may be an underlying chronic tendinopathy. Acute or chronic paratendinopathy may occur as a separate entity or combined with Achilles injury. In this article, the spectrum of athletic injuries of the plantar fascia and Achilles is described, illustrated by imaging findings from the London 2012 Olympic games.
Gao, Wei-Ping; Liu, Min; Zhang, Yi-Biao
2010-06-01
To observed the clinical efficacy on dry eye syndrome treated with acupuncture on the acupoints around the eyes. Fifty-six cases of dry eye syndrome were divided into two groups, acupuncture group and western medicine group, 28 cases in each one. In acupuncture group, acupuncture was applied to Jingming (BL 1), Cuanzhu (BL 2), Sizhukong (TE 23), Tongziliao (GB 1), etc. In western medicine group, the topical artificial tear eye drops were administered. The corneal fluorescein staining, breaking-up time (BUT), tear volume and the symptom score were observed before and after treatment in two groups. In comparison before and after treatment in acupuncture group, the statistical significant difference presented in BUT, tear volume and the symptom score (all P < 0.01). In comparison before and after treatment in western medicine group, the statistical significant difference presented in corneal staining, BUT and the symptom score (P < 0.01). The improvements in BUT, tear volume and the symptom score in acupuncture group were superior to those in western medicine group (P < 0.01). Acupuncture on the acupoints around the eyes achieves a quite good efficacy on dry eye syndrome.
Effect of diquafosol tetrasodium eye drop for persistent dry eye after laser in situ keratomileusis.
Mori, Yosai; Nejima, Ryohei; Masuda, Ayami; Maruyama, Yoko; Minami, Keiichiro; Miyata, Kazunori; Amano, Shiro
2014-07-01
To evaluate the effect of diquafosol tetrasodium (DQS) for the treatment of persistent dry eye after laser in situ keratomileusis (LASIK). Miyata Eye Hospital, Miyazaki, Japan. Noncomparative case series. This prospective study included 30 eyes of 15 patients in whom dry eye had persisted for over 12 months after LASIK, and the symptoms had not improved with artificial tears and sodium hyaluronate treatment. In addition, treatment with DQS 3% eye drops, 6 times a day, was performed for 12 weeks. Best-corrected visual acuity, tear secretion with the Schirmer test, tear break-up time, and fluorescein and lissamine green staining scores on the cornea and conjunctiva were examined before and at 1, 4, and 12 weeks after the addition. A subjective questionnaire of 14 symptoms was also assessed before and 12 weeks after treatment. The fluorescein and lissamine green staining scores significantly improved over 12 weeks; however, the best-corrected visual acuity and tear secretion did not change. The symptoms of fatigue, dryness, grittiness, discomfort, difficulty in reading, and discomfort within the area of dryness improved after the additional DQS treatment. The DQS treatment improved the subjective and objective symptoms of persistent dry eye after LASIK. Increased mucin production because of the addition of DQS probably improved the tear film stability and reduced the symptoms of dry eye in patients who had persistent dry eye after LASIK.
Asbell, Penny; Vingrys, Algis J; Tan, Jacqueline; Ogundele, Abayomi; Downie, Laura E; Jerkins, Gary; Shettle, Lee
2018-05-01
To evaluate the clinical effects of using fixed (four times daily [QID]) versus as-needed (PRN) dosing of an artificial tear product (polyethylene glycol/propylene glycol [PEG/PG]; Systane Ultra) in individuals with dry eye disease. In this prospective, multicenter, observer-masked, active-control, parallel-group trial, participants were randomized (1:2 allocation) to receive 1 drop of PEG/PG QID (n = 34) or PRN (n = 63) for 28 days. The primary endpoint was change from baseline in the total ocular surface staining (TOSS) score (according to the Oxford scale) at day 28. At day 28, the change from baseline in least squares mean (LSM) TOSS scores for QID and PRN groups were -1.19 and -0.94, respectively (treatment difference [TD]: -0.26; 95% confidence interval [CI]: -∞ to 0.21; P = 0.184); superiority of QID versus PRN dosing was not established, as the upper limit of one-sided 95% CI for TD was not <0 (prespecified limit). At day 28, for QID and PRN groups, the LSM change from baseline in Impact of Dry Eye on Everyday Life (IDEEL) scores was symptom-bother, -7.0 and -2.94 (TD: -4.06, P = 0.037); treatment effectiveness, 2.43 and 0.16 (TD: 2.28, P = 0.278); and treatment-related inconvenience, -11.56 and -2.77 (TD: -8.8, P = 0.996), respectively. Incidence of adverse events was low (≤3.2%) in both the groups; no serious adverse events were reported. QID dosing of PEG/PG was not superior to PRN dosing in terms of ocular staining. The IDEEL symptom-bother score favored QID dosing, suggesting that regular use of artificial tears may provide better symptomatic relief than PRN use. (ClinicalTrials.gov number, NCT02446015.).
Vandermeer, G; Chamy, Y; Pisella, P-J
2018-02-01
Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the Optical Quality Analyzing System, Visiometrics (OQAS). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an ocular surface disease index (OSDI) score >23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there were no significant variations in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204, P<0.05), the average slope of OSI (0.04 versus 0.01, P<0.05) and the number of blinks (4.2 versus 2.8, P<0.05). Among the patients, 65% preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Vandermeer, G; Chamy, Y; Pisella, P-J
2018-03-01
Dry eye is defined by a tear film instability resulting in variable but systematic fluctuations in the quality of vision. Variability in optical quality can be demonstrated using a double pass aberrometer such as the OQAS (Optical Quality Analyzing System, Visiometrics). The goal of this work is to compare fluctuations in objective quality of vision measured by OQAS between treatment with normal saline eye drops and treatment with carmellose 0.5% and hyaluronic acid 0.1% (Optive Fusion [OF], Allergan) in patients with moderate dry eye syndrome. Optical quality was measured by evaluating the variations in the Optical Scattering Index (OSI) over 20seconds using the OQAS. Inclusion criteria were dry eye syndrome with an Ocular Surface Disease Index (OSDI) score>23 treated only with artificial tears. The patients were their own controls: OF in one eye and normal saline in the fellow eye. The choice of the subject eye and control eye was determined in a randomized fashion. OSI variations were measured in each eye before instillation, 5minutes and 2hours after instillation. The primary endpoint was OSI fluctuation over 20seconds of measurement. Secondary endpoints were the number of blinks and patient's preference (preferred eye). Preliminary results were obtained on 19 patients. Average OSDI score was 36.8. Visual acuity was 10/10 with no significant difference between the two eyes. Prior to instillation, there was no significant difference between "normal saline" and "OF" eyes in terms of OSI, OSI variability or number of blinks. In the normal saline eye, there was no significant variation in mean OSI, OSI variability, OSI slope, or number of blinks. However, in the "OF" eye, there was a significant variation between initial and 2-hour OSI variability (0.363 versus 0.204; P<0.05), the average slope of OSI (0.04 versus 0.01; P<0.05) and the number of blinks (4.2 versus 2.8; P<0.05). Sixty-five percent of patients preferred the OF eye, 24% did not have a preference, and 11% preferred the normal saline eye. Objective quality of vision measured by OQAS is an interesting parameter for evaluating the effectiveness of a lacrimal substitute. The purpose of artificial tears is, among other things, to provide comfort and a reduction of dry eye symptoms such as poor quality of vision. This study demonstrates that 0.5% carmellose and 0.1% hyaluronic acid allowed better stabilization of the tear film and thus a significant improvement in the quality of vision compared to normal saline. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance
Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.
2017-01-01
Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026
Nie, Xiao-wei; Sun, Li-jun; Hao, Yue-wen; Yang, Guang-xiao; Wang, Quan-ying
2011-03-01
To synthesize the minimal and artificial HRE, and to insert it into the anterior extremity of CMV promoter of a AAV plasmid, and then to construct the AAV regulated by hypoxic-responsive element which was introduced into 293 cell by method of Ca3(PO4)2 using three plasmids. Thus obtaining the adenoassociated virus vector regulated by hypoxic-responsive element was possibly used for gene therapy in ischemia angiocardiopathy and cerebrovascular disease. Artificially synthesize the 36 bp nucleotide sequences of four connection in series HIF-binding sites A/GCGTG(4×HBS)and a 35 bp nucleotide sequences spacing inserted into anterior extremity of CMV promoter TATA Box, then amplified by PCR. The cDNA fragment was confirmed to be right by DNA sequencing. Molecular biology routine method was used to construct a AAV vector regulated by minimal hypoxic-responsive element after the normal CMV promoter in AAV vector was replaced by the CMV promoter included minimal hypoxic-responsive element. Then, NT4-6His-PR39 fusogenic peptide was inserted into MCS of the plasmid, the recombinant AAV vector was obtained by three plasmid co-transfection in 293 cells, in which we can also investigate the expression of 6×His using immunochemistry in hypoxia environment. Artificial HRE was inserted into anterior extremity of CMV promoter and there was a correct spacing between the HRE and the TATA-box. The DNA sequencing and restriction enzyme digestion results indicated that the AAV regulated by hypoxic-responsive element was successfully constructed. Compared to the control group, the expressions of 6×His was significantly increased in the experimental groups in hypoxia environment, which confirmed that the AAV effectually regulated by the minimal HRE was inserted into anterior extremity of CMV promoter. The HRE is inserted into anterior extremity of CMV promoter to lack incision enzyme recognition site by PCR. And eukaryotic expression vector regulated by hypoxic-responsive is constructed. The AAV effectually regulated by the minimal HRE inserted into anterior extremity of CMV promoter. The vector is successfully constructed and it has important theoretical and practical value in the synteresis and therapy of ischemia angiocardiopathy and cerebrovascular disease.
[Transplantation of autologous labial salivary glands for severe dry eye].
Luo, Shun-rong; Zou, Liu-he; Yan, Chao; Pan, Zhi-qiang; Liu, Jing-ming; Chen, Zhi-yuan; Yin, Wei-hong
2013-01-01
Autologous labial salivary gland transplantation has been a promising alternative for the treatment of severe dry eye. In this article, we describe the results of the ocular surface changes after labial salivary gland transplantation and investigate the feasibility of this treatment. The results of this technique in 8 patients (eyes) who suffered from severe dry eye were prospectively analyzed after surgery (follow-up of 6 months). The best-corrected visual acuity, Schirmer I test, degree of discomfort, usage of pharmaceutical tear substitutes, tear interferometry and slit lamp examination were investigated at different time before and after surgery. All grafts remained viable and the survival rate is 100%. All patients showed significant increase in the Schirmer's test and they expressed great improvement in their ocular discomfort. The use of artificial tear substitutes was reduced because of the increased ocular surface lubrication. Although the authors' long-term experience still is limited, we believe that the procedure is a promising alternative approach for severe dry eye.
Inaba, Takaaki; Tanaka, Yasuhisa; Tamaki, Shusaku; Ito, Tomotaka; Ntambi, James M; Tsubota, Kazuo
2018-02-20
The stearoyl-CoA desaturase (SCD) family of enzymes catalyzes monounsaturated fatty acid synthesis by inserting a cis double bond at the Δ9 position of saturated fatty acids. Disruption of these enzymes has been reported to induce a severe dry skin phenotype. Since lipid abnormalities in the meibomian glands have been associated with dry eye, we analyzed selected eye tissues contributing to tear volume and composition in genetically SCD-1-deficient mice (SCD-1 KO), including the lacrimal glands and conjunctiva. Previous histopathological analysis had revealed atrophy and loss of meibomian glands; taken together with the increased goblet cell and MUC5AC expression in the conjunctiva reported here, these findings suggest that the tear volume and mucin levels secreted are enhanced in the absence of lipid secretion as a compensatory mechanism. The expression of lipid metabolism genes in lacrimal glands was decreased in SCD1 KO mice. Thus, these results provide new pathophysiological mechanisms to pursue with regard to meibomian gland dysfunction. In addition, lack of SCD-1 causes a compensatory increase in the tear volume and mucin levels associated with changes in expression of lipid metabolism genes. These results may be useful as a new concept for dry eye treatment strategies.
Sambursky, Robert
2016-01-01
The presence of clinically significant inflammation has been confirmed in the tears of 40%-65% of patients with symptoms of dry eye. Ocular surface inflammation may lead to tear film instability, epithelial cell irregularities, and permeability, resulting in chronic symptomatic pain and fluctuating vision as well as negative surgical outcomes. A retrospective single center medical chart review of 100 patients was conducted. All patients were tested with the InflammaDry test to determine if patients exhibited elevated levels of matrix metalloproteinase 9 (MMP-9). InflammaDry-positive patients were started on a combination of cyclosporine 0.05% twice daily, 2,000-4,000 mg oral omega-3 fatty acids, and frequent artificial tear replacement. InflammaDry-negative patients were started on 2,000-4,000 mg of oral omega-3 fatty acids and frequent artificial tear replacement. Each patient was retested at ~90 days. A symptom questionnaire was performed at the initial visit and at 90 days. 60% of the patients with dry eye symptoms tested positive for elevated MMP-9 at the initial visit. 78% of all patients returned for follow-up at ~90 days including 80% (48/60) of the previously InflammaDry-positive patients and 75% (30/40) of the previously InflammaDry-negative patients. A follow-up symptom questionnaire reported at least 75% symptomatic improvement in 65% (31/48) of the originally InflammaDry-positive patients and in 70% (21/30) of the initially InflammaDry-negative patients. Symptomatic improvement of at least 50% was reported in 85% (41/48) of previously InflammaDry-positive patients and 86% (26/30) of previously InflammaDry-negative patients. Following treatment, 54% (26/48) of previously InflammaDry-positive patients converted to a negative InflammaDry result. Identifying which symptomatic dry eye patients have underlying inflammation may predict patient responses to treatment and influence clinical management strategies.
Sambursky, Robert
2016-01-01
Background The presence of clinically significant inflammation has been confirmed in the tears of 40%–65% of patients with symptoms of dry eye. Ocular surface inflammation may lead to tear film instability, epithelial cell irregularities, and permeability, resulting in chronic symptomatic pain and fluctuating vision as well as negative surgical outcomes. Patients and methods A retrospective single center medical chart review of 100 patients was conducted. All patients were tested with the InflammaDry test to determine if patients exhibited elevated levels of matrix metalloproteinase 9 (MMP-9). InflammaDry-positive patients were started on a combination of cyclosporine 0.05% twice daily, 2,000–4,000 mg oral omega-3 fatty acids, and frequent artificial tear replacement. InflammaDry-negative patients were started on 2,000–4,000 mg of oral omega-3 fatty acids and frequent artificial tear replacement. Each patient was retested at ~90 days. A symptom questionnaire was performed at the initial visit and at 90 days. Results 60% of the patients with dry eye symptoms tested positive for elevated MMP-9 at the initial visit. 78% of all patients returned for follow-up at ~90 days including 80% (48/60) of the previously InflammaDry-positive patients and 75% (30/40) of the previously InflammaDry-negative patients. A follow-up symptom questionnaire reported at least 75% symptomatic improvement in 65% (31/48) of the originally InflammaDry-positive patients and in 70% (21/30) of the initially InflammaDry-negative patients. Symptomatic improvement of at least 50% was reported in 85% (41/48) of previously InflammaDry-positive patients and 86% (26/30) of previously InflammaDry-negative patients. Following treatment, 54% (26/48) of previously InflammaDry-positive patients converted to a negative InflammaDry result. Conclusion Identifying which symptomatic dry eye patients have underlying inflammation may predict patient responses to treatment and influence clinical management strategies. PMID:27920494
Tear film thickness after treatment with artificial tears in patients with moderate dry eye disease.
Schmidl, Doreen; Schmetterer, Leopold; Witkowska, Katarzyna J; Unterhuber, Angelika; dos Santos, Valentin Aranha; Kaya, Semira; Nepp, Johannes; Baar, Carina; Rosner, Peter; Werkmeister, René M; Garhofer, Gerhard
2015-04-01
This study was designed to investigate the effect of a single-drop instillation of different lacrimal substitutes on tear film thickness (TFT) assessed with optical coherence tomography in patients with mild to moderate dry eye disease. The study was performed in a randomized, double-masked, controlled parallel group design. Patients received a single dose of either unpreserved trehalose 30 mg/mL and sodium hyaluronate 1.5 mg/mL (TH-SH, Thealoz Duo), unpreserved sodium hyaluronate, 0.15% (HA, Hyabak) or sodium chloride, 0.9% (NaCl, Hydrabak) eye drops. Sixty patients finished the study according to the protocol. TFT was measured with a custom-built ultrahigh-resolution Fourier domain optical coherence tomography system providing a resolution of 1.2 μm. The mean TFT before treatment was 2.5 ± 0.4 μm. Ten minutes after instillation, TFT significantly increased in the TH-SH group from 2.4 ± 0.4 to 3.1 ± 0.9 μm (P < 0.01) and in the HA group from 2.4 ± 0.3 to 2.9 ± 0.5 μm (P < 0.01), whereas no significant change was observed in the NaCl group (from 2.6 ± 0.4 to 2.7 ± 0.4 μm, P = 0.76). The increase in TFT remained statistically significant up to 240 minutes after administration of TH-SH. In contrast, the increase in TFT after administration of HA was only statistically significant at 10, 20, and 40 minutes after drop instillation. The findings of this study indicate that single instillation of TH-SH and HA eye drops increases TFT in patients with dry eye disease. The data also indicate longer corneal residence of the TH-containing eye drops. The effect of multiple instillation and long-term use of artificial tears on TFT warrants further investigation.
Fouda, Sameh M; Mattout, Hala K
2017-06-01
Laser in situ keratomelieusis (LASIK) is one of the commonest refractive procedures performed nowadays. The dry eye problem is nearly universal in all patients after LASIK and it can be so annoying that the post-operative patient satisfaction is sometimes precluded. Conventional treatment includes the use of artificial tears. Alternative methods such as punctal plugs and botulinum toxin injection can be used for the management of post-LASIK dry eye. The aim of this study is to compare botulinum toxin injection in the orbicularis muscle to lacrimal punctal plugs for the control of post-LASIK dry eye manifestations. This is a prospective study that included 60 patients who had LASIK eye surgery for correction of refractive errors. Patients were randomly assigned to one of three methods of dry eye management; the first method was conventional medical treatment with preservative-free tear substitutes only (group A: 20 patients = 40 eyes); the second method was intraoperative injection of botulinum toxin A (BTA) in the orbicularis muscle below the lower punctum of both eyes (group B: 20 patients = 40 eyes) and the third method was intraoperative insertion of temporary extended duration silicone punctal plugs in the lower punctum of both eyes (group C: 20 patients = 40 eyes). In the first follow-up visit after 2 weeks, the two test groups (B, C) showed a statistically significant increase in both tear film break up time (TBUT) and Schirmer test score with a decrease in the OSDI score and daily frequency of lubricants used in comparison to the control group A. These differences were maintained in the next follow-up visit but they became statistically insignificant at the 3rd and 6th post-operative months. Complications were encountered more in the punctal plug patients (60%) than in BTA patients (25%) and this difference was statistically significant. The use of BTA injection to control dry eye symptoms by inducing temporary punctal ectropion is an effective method to improve patient satisfaction after LASIK eye surgery. It has higher level of patient satisfaction and fewer complications in comparison to punctal plugs or topical standard dry eye treatment.
Punctal occlusion for dry eye syndrome.
Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D
2017-06-26
Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We assessed the evidence for eight comparisons.Five trials compared punctal plugs with no punctal plugs (control). Three of these trials employed a sham treatment and two trials observed the control group. Two trials did not report outcome data relevant to this review. There was very low-certainty evidence on symptomatic improvement. The three trials that reported this outcome used different scales to measure symptoms. In all three trials, there was little or no improvement in symptom scores with punctal plugs compared with no punctal plugs. Low-certainty evidence from one trial suggested less ocular surface staining in the punctal plug group compared with the no punctal plug group however this difference was small and possibly clinically unimportant (mean difference (MD) in fluorescein staining score -1.50 points, 95% CI -1.88 to -1.12; eyes = 61). Similarly there was a small difference in tear film stability with people in the punctal plug group having more stability (MD 1.93 seconds more, 95% CI 0.67 to 3.20; eyes = 28, low-certainty evidence). The number of artificial tear applications was lower in the punctal plug group compared with the no punctal plugs group in one trial (MD -2.70 applications, 95% CI -3.11 to -2.29; eyes = 61, low-certainty evidence). One trial with low-certainty evidence reported little or no difference between the groups in Schirmer scores, but did not report any quantitative data on aqueous tear production. Very low-certainty evidence on adverse events suggested that events occurred reasonably frequently in the punctal plug group and included epiphora, itching, tenderness and swelling of lids with mucous discharge, and plug displacement.One trial compared punctal plugs with cyclosporine (20 eyes) and one trial compared punctal plugs with oral pilocarpine (55 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.Five trials compared punctal plugs with artificial tears. In one of the trials punctal plugs was combined with artificial tears and compared with artificial tears alone. There was very low-certainty evidence on symptomatic improvement. Low-certainty evidence of little or no improvement in ocular surface staining comparing punctal plugs with artificial tears (MD right eye 0.10 points higher, 0.56 lower to 0.76 higher, MD left eye 0.60 points higher, 0.10 to 1.10 higher) and low-certainty evidence of little or no difference in aqueous tear production (MD 0.00 mm/5 min, 0.33 lower to 0.33 higher)Three trials compared punctal plugs in the upper versus the lower puncta, and none of them reported the review outcomes at long-term follow-up. One trial with very low-certainty evidence reported no observed complications, but it was unclear which complications were collected.One trial compared acrylic punctal plugs with silicone punctal plugs and the trial reported outcomes at approximately 11 weeks of follow-up (36 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.One trial compared intracanalicular punctal plugs with silicone punctal plugs at three months follow-up (57 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.Finally, two trials with very low-certainty evidence compared collagen punctal plugs versus silicone punctal plugs (98 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Although the investigators of the individual trials concluded that punctal plugs are an effective means for treating dry eye signs and symptoms, the evidence in this systematic review suggests that improvements in symptoms and commonly tested dry eye signs are inconclusive. Despite the inclusion of 11 additional trials, the findings of this updated review are consistent with the previous review published in 2010. The type of punctal plug investigated, the type and severity of dry eye being treated, and heterogeneity in trial methodology confounds our ability to make decisive statements regarding the effectiveness of punctal plug use. Although punctal plugs are believed to be relatively safe, their use is commonly associated with epiphora and, less commonly, with inflammatory conditions such as dacryocystitis.
Punctal occlusion for dry eye syndrome
Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D
2017-01-01
Background Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. Objectives To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 Selection criteria We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Data collection and analysis Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. Main results We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We assessed the evidence for eight comparisons. Five trials compared punctal plugs with no punctal plugs (control). Three of these trials employed a sham treatment and two trials observed the control group. Two trials did not report outcome data relevant to this review. There was very low-certainty evidence on symptomatic improvement. The three trials that reported this outcome used different scales to measure symptoms. In all three trials, there was little or no improvement in symptom scores with punctal plugs compared with no punctal plugs. Low-certainty evidence from one trial suggested less ocular surface staining in the punctal plug group compared with the no punctal plug group however this difference was small and possibly clinically unimportant (mean difference (MD) in fluorescein staining score -1.50 points, 95% CI -1.88 to -1.12; eyes = 61). Similarly there was a small difference in tear film stability with people in the punctal plug group having more stability (MD 1.93 seconds more, 95% CI 0.67 to 3.20; eyes = 28, low-certainty evidence). The number of artificial tear applications was lower in the punctal plug group compared with the no punctal plugs group in one trial (MD -2.70 applications, 95% CI -3.11 to -2.29; eyes = 61, low-certainty evidence). One trial with low-certainty evidence reported little or no difference between the groups in Schirmer scores, but did not report any quantitative data on aqueous tear production. Very low-certainty evidence on adverse events suggested that events occurred reasonably frequently in the punctal plug group and included epiphora, itching, tenderness and swelling of lids with mucous discharge, and plug displacement. One trial compared punctal plugs with cyclosporine (20 eyes) and one trial compared punctal plugs with oral pilocarpine (55 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Five trials compared punctal plugs with artificial tears. In one of the trials punctal plugs was combined with artificial tears and compared with artificial tears alone. There was very low-certainty evidence on symptomatic improvement. Low-certainty evidence of little or no improvement in ocular surface staining comparing punctal plugs with artificial tears (MD right eye 0.10 points higher, 0.56 lower to 0.76 higher, MD left eye 0.60 points higher, 0.10 to 1.10 higher) and low-certainty evidence of little or no difference in aqueous tear production (MD 0.00 mm/5 min, 0.33 lower to 0.33 higher) Three trials compared punctal plugs in the upper versus the lower puncta, and none of them reported the review outcomes at long-term follow-up. One trial with very low-certainty evidence reported no observed complications, but it was unclear which complications were collected. One trial compared acrylic punctal plugs with silicone punctal plugs and the trial reported outcomes at approximately 11 weeks of follow-up (36 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. One trial compared intracanalicular punctal plugs with silicone punctal plugs at three months follow-up (57 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Finally, two trials with very low-certainty evidence compared collagen punctal plugs versus silicone punctal plugs (98 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Authors' conclusions Although the investigators of the individual trials concluded that punctal plugs are an effective means for treating dry eye signs and symptoms, the evidence in this systematic review suggests that improvements in symptoms and commonly tested dry eye signs are inconclusive. Despite the inclusion of 11 additional trials, the findings of this updated review are consistent with the previous review published in 2010. The type of punctal plug investigated, the type and severity of dry eye being treated, and heterogeneity in trial methodology confounds our ability to make decisive statements regarding the effectiveness of punctal plug use. Although punctal plugs are believed to be relatively safe, their use is commonly associated with epiphora and, less commonly, with inflammatory conditions such as dacryocystitis. PMID:28649802
Influence of artificial shock absorbers on human gait.
Voloshin, A; Wosk, J
1981-10-01
The effect of artificial shock absorbers on the human gait and the technique for its quantitative evaluation have been studied. The results obtained have shown that viscoelastic inserts reduced the amplitude of the incoming shock waves bearing upon the musculoskeletal system as a result of the heel strike, by 42 percent (mean value). Conservative treatment, using such inserts for patients with different clinical symptoms of degenerative joint diseases, has shown excellent results. Seventy-eight percent of the clinical symptoms disappeared, while satisfactory improvement was reported in 17 percent of the subjects.
Initial and long-term use of inserts by red-cockaded woodpeckers
Daniel Saenz; Richard N. Conner; Christopher S. Collins; D. Craig Rudolph
2001-01-01
Artificial cavities have become a standard management technique for red-cockaded woodpeckers (Picoides borealis). Seventy cavity inserts were installed in our study sites on the Angelina National Forest in eastern Texas from 1990 to 1995. Eighty-two percent of the inserts were used for at least one year. It is still too early to make a direct...
Arthroscopic-assisted latissimus dorsi transfer for subscapularis deficiency.
Kany, Jean; Guinand, Régis; Croutzet, Pierre; Valenti, Philippe; Werthel, Jean David; Grimberg, Jean
2016-04-01
Few salvage procedures have been described in case of irreparable subscapularis tear and with variable outcomes. Latissimus dorsi transfer has been widely proposed as a transfer for irreparable posterio-superior rotator cuff tear with good outcomes. The anatomic feasibility of the latissimus dorsi to reconstruct the antero-superior irreparable rotator cuff tear has been suggested, but no clinical study has ever been published. We hypothesized that it was possible to use an arthroscopic-assisted latissimus dorsi transfer to reconstruct the subscapularis function. Five patients were enrolled. A 5-7-cm axillary incision was performed to release the latissimus dorsi tendon from its humeral insertion, the teres major muscle and the apex of the scapula. Afterwards, under arthroscopic control, a 7-mm-diameter tunnel was drilled at the anterior and superior part of the humeral head with an oblique inferior and posterior direction. The tubularized latissimus dorsi tendon was introduced into the tunnel and fixed with a ZipLoop on the posterior humeral cortex. The authors show overall good experience with this technique. Level IV-a, case series.
Toda, Ikuko; Ide, Takeshi; Fukumoto, Teruki; Ichihashi, Yoshiyuki; Tsubota, Kazuo
2014-03-01
To evaluate the possible advantages of combination therapy with diquafosol tetrasodium and sodium hyaluronate for dry eye after laser in situ keratomileusis (LASIK). Prospective randomized comparative trial. A total of 206 eyes of 105 patients who underwent LASIK were enrolled in this study. Patients were randomly assigned to 1 of 4 treatment groups according to the postoperative treatment: artificial tears, sodium hyaluronate, diquafosol tetrasodium, and a combination of hyaluronate and diquafosol. Questionnaire responses reflecting subjective dry eye symptoms, uncorrected and corrected visual acuity, functional visual acuity, manifest refraction, tear break-up time, fluorescein corneal staining, Schirmer test, and corneal sensitivity were examined before and 1 week and 1 month after LASIK. Distance uncorrected visual acuity was significantly better in the combination group than in the hyaluronate group 1 week and 1 month after LASIK. Near uncorrected visual acuity was significantly better in the combination group than in the artificial tear and diquafosol groups 1 week and 1 month after LASIK. Distance functional visual acuity improved significantly only in the combination group 1 month after LASIK. The Schirmer value in the combination group was significantly higher than that in the hyaluronate group at 1 month after LASIK. Subjective dry eye symptoms in the combination group improved significantly compared with those in the other groups 1 week after surgery. Our results suggest that hyaluronate and diquafosol combination therapy is beneficial for early stabilization of visual performance and improvement of subjective dry eye symptoms in patients after LASIK. Copyright © 2014 Elsevier Inc. All rights reserved.
Paper-based surfaced enhanced Raman spectroscopy for drug level testing with tear fluid
NASA Astrophysics Data System (ADS)
Yamada, Kenji; Yokoyama, Moe; Jeong, Hieyong; Kido, Michiko; Ohno, Yuko
2015-07-01
The purpose of this study was to show the effectiveness of therapeutic drug level testing by Paper-based Surfaced Enhanced Raman Spectroscopy (PSERS) for artificial lacrimal fluid. We have been used substrates which consist of a common filter paper and gold nano-rods. The targets were Phenobarbital (PB) which dissolved in artificial lacrimal fluid. We measured them using PSERS which the wavelength was 785nm, the power was 30mW. It was found that there were the strong peaks of PB at 997cm-1 and 1026cm-1 which corresponded with solid PB spectral peak for 1mM artificial lacrimal fluid. The results demonstrated the usefulness of this method. It is concluded that our method for therapeutic drug level testing is very efficient.
Effect of viscosity on tear drainage and ocular residence time.
Zhu, Heng; Chauhan, Anuj
2008-08-01
An increase in residence time of dry eye medications including artificial tears will likely enhance therapeutic benefits. The drainage rates and the residence time of eye drops depend on the viscosity of the instilled fluids. However, a quantitative understanding of the dependence of drainage rates and the residence time on viscosity is lacking. The current study aims to develop a mathematical model for the drainage of Newtonian fluids and also for power-law non-Newtonian fluids of different viscosities. This study is an extension of our previous study on the mathematical model of tear drainage. The tear drainage model is modified to describe the drainage of Newtonian fluids with viscosities higher than the tear viscosity and power-law non-Newtonian fluids with rheological parameters obtained from fitting experimental data in literature. The drainage rate through canaliculi was derived from the modified drainage model and was incorporated into a tear mass balance to calculate the transients of total solute quantity in ocular fluids and the bioavailability of instilled drugs. For Newtonian fluids, increasing the viscosity does not affect the drainage rate unless the viscosity exceeds a critical value of about 4.4 cp. The viscosity has a maximum impact on drainage rate around a value of about 100 cp. The trends are similar for shear thinning power law fluids. The transients of total solute quantity, and the residence time agrees at least qualitatively with experimental studies. A mathematical model has been developed for the drainage of Newtonian fluids and power-law fluids through canaliculi. The model can quantitatively explain different experimental observations on the effect of viscosity on the residence of instilled fluids on the ocular surface. The current study is helpful for understanding the mechanism of fluid drainage from the ocular surface and for improving the design of dry eye treatments.
Nguyen, Yann; Bernardeschi, Daniele; Kazmitcheff, Guillaume; Miroir, Mathieu; Vauchel, Thomas; Ferrary, Evelyne; Sterkers, Olivier
2015-02-01
Loading otoprotective drug into cochlear implant might change its mechanical properties, thus compromising atraumatic insertion. This study evaluated the effect of incorporation of dexamethasone (DXM) in the silicone of cochlear implant arrays on insertion forces. Local administration of DXM with embedded array can potentially reduce inflammation and fibrosis after cochlear implantation procedure to improve hearing preservation and reduce long-term impedances. Four models of arrays have been tested: 0.5-mm distal diameter array (n = 5) used as a control, drug-free 0.4-mm distal diameter array (n = 5), 0.4-mm distal diameter array with 1% eluded DXM silicone (n = 5), and 0.4-mm distal diameter array with 10% eluded DXM silicone (n = 5). Via a motorized insertion bench, each array has been inserted into an artificial scala tympani model. The forces were recorded by a 6-axis force sensor. Each array was tested seven times for a total number of 140 insertions. During the first 10-mm insertion, no difference between the four models was observed. From 10- to 24-mm insertion, the 0.5-mm distal diameter array presented higher insertion forces than the drug-free 0.4-mm distal diameter arrays, with or without DXM. Friction forces for drug-free 0.4-mm distal diameter array and 0.4-mm distal diameter DXM eluded arrays were similar on all insertion lengths. Incorporation of DXM in silicone for cochlear implant design does not change electrode array insertion forces. It does not raise the risk of trauma during array insertion, making it suitable for long-term in situ administration to the cochlea.
Rotator cuff tendon connections with the rotator cable.
Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo
2017-07-01
The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.
[The influence of sodium hyaluronate solution and artificial tears on higher-order aberrations].
Yamashita, Tsutomu; Ochi, Shintarou; Inoue, Yasushi; Miki, Atsushi; Kiryu, Junichi; Tabuchi, Akio
2013-12-01
To investigate the influence of sodium hyaluronate solution (HA) and artificial tears (AT) on higher-order aberrations (HOAs). Twenty four eyes of 24 normal subjects and 11 eyes of 11 dry eye patients were examined. Cornea and ocular wavefront aberrations (total, spherical-like and coma-like) were measured with a Hartmann-Shack wavefront aberrometer before and after 0.1% or 0.3% HA, AT. The consecutively obtained data of the cornea and ocular HOAs were analyzed in the central 4-mm diameter for coma-like, spherical-like and total HOAs. Average HOAs, as well as fluctuation index (FI) and stability index (SI) of the HOAs over time were compared between the two groups. In normal subjects, the AVE of all aberration parameters and FI showed an increase depending on viscosity of the HA (p < 0.001). After AT and 0.1% HA treatment the cornea aberration of the dry eye patients changed from a sawtooth pattern to a stable pattern. Cornea HOAs decreased, and the optical characteristics showed improvement after AT and 0.1% HA in the dry eye patients. HOAs increased depending on the viscosity of the HA, and optical stability worsened.
In vitro modifications of the scala tympani environment and the cochlear implant array surface.
Kontorinis, Georgios; Scheper, Verena; Wissel, Kirsten; Stöver, Timo; Lenarz, Thomas; Paasche, Gerrit
2012-09-01
To investigate the influence of alterations of the scala tympani environment and modifications of the surface of cochlear implant electrode arrays on insertion forces in vitro. Research experimental study. Fibroblasts producing neurotrophic factors were cultivated on the surface of Nucleus 24 Contour Advance electrodes. Forces were recorded by an Instron 5542 Force Measurement System as three modified arrays were inserted into an artificial scala tympani model filled with phosphate-buffered saline (PBS). The recorded forces were compared to control groups including three unmodified electrodes inserted into a model filled with PBS (unmodified environment) or Healon (current practice). Fluorescence microscopy was used before and after the insertions to identify any remaining fibroblasts. Additionally, three Contour Advance electrodes were inserted into an artificial model, filled with alginate/barium chloride solution at different concentrations, while insertion forces were recorded. Modification of the scala tympani environment with 50% to 75% alginate gel resulted in a significant decrease in the insertion forces. The fibroblast-coated arrays also led to decreased forces comparable to those recorded with Healon. Fluorescence microscopy revealed fully cell-covered arrays before and partially covered arrays after the insertion; the fibroblasts on the arrays' modiolar surface remained intact. Modifications of the scala tympani's environment with 50% to 75% alginate/barium chloride and of the cochlear implant electrode surface with neurotrophic factor-producing fibroblasts drastically reduce the insertion forces. As both modifications may serve future intracochlear therapies, it is expected that these might additionally reduce possible insertion trauma. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Joo, Han-Sung; Yang, Hong-So; Park, Sang-Won; Kim, Hyun-Seung; Yun, Kwi-Dug; Ji, Min-Kyung; Lim, Hyun-Pil
2015-06-01
This study evaluated the fracture load of customized zirconia abutments with titanium insert according to preparation depths, with or without 5-year artificial aging. Thirty-six identical lithium disilicate crowns (IPS e.max press) were fabricated to replace a maxillary right central incisor and cemented to the customized zirconia abutment with titanium insert on a 4.5×10 mm titanium fixture. Abutments were fabricated with 3 preparation depths (0.5 mm, 0.7 mm, and 0.9 mm). Half of the samples were then processed using thermocycling (temperature: 5-55℃, dwelling time: 120s) and chewing simulation (1,200,000 cycles, 49 N load). All specimens were classified into 6 groups depending on the preparation depth and artificial aging (non-artificial aging groups: N5, N7, N9; artificial aging groups: A5, A7, A9). Static load was applied at 135 degrees to the implant axis in a universal testing machine. Statistical analyses of the results were performed using 1-way ANOVA, 2-way ANOVA, independent t-test and multiple linear regression. The fracture loads were 539.28 ± 63.11 N (N5), 406.56 ± 28.94 N (N7), 366.66 ± 30.19 N (N9), 392.61 ± 50.57 N (A5), 317.94 ± 30.05 N (A7), and 292.74 ± 37.15 N (A9). The fracture load of group N5 was significantly higher than those of group N7 and N9 (P<.017). Consequently, the fracture load of group A5 was also significantly higher than those of group A7 and A9 (P<.05). After artificial aging, the fracture load was significantly decreased in all groups with various preparation depths (P<.05). The fracture load of a single anterior implant restored with lithium disilicate crown on zirconia abutment with titanium insert differed depending on the preparation depths. After 5-year artificial aging, the fracture loads of all preparation groups decreased significantly.
Joo, Han-Sung; Yang, Hong-So; Park, Sang-Won; Kim, Hyun-Seung; Yun, Kwi-Dug; Ji, Min-Kyung
2015-01-01
PURPOSE This study evaluated the fracture load of customized zirconia abutments with titanium insert according to preparation depths, with or without 5-year artificial aging. MATERIALS AND METHODS Thirty-six identical lithium disilicate crowns (IPS e.max press) were fabricated to replace a maxillary right central incisor and cemented to the customized zirconia abutment with titanium insert on a 4.5×10 mm titanium fixture. Abutments were fabricated with 3 preparation depths (0.5 mm, 0.7 mm, and 0.9 mm). Half of the samples were then processed using thermocycling (temperature: 5-55℃, dwelling time: 120s) and chewing simulation (1,200,000 cycles, 49 N load). All specimens were classified into 6 groups depending on the preparation depth and artificial aging (non-artificial aging groups: N5, N7, N9; artificial aging groups: A5, A7, A9). Static load was applied at 135 degrees to the implant axis in a universal testing machine. Statistical analyses of the results were performed using 1-way ANOVA, 2-way ANOVA, independent t-test and multiple linear regression. RESULTS The fracture loads were 539.28 ± 63.11 N (N5), 406.56 ± 28.94 N (N7), 366.66 ± 30.19 N (N9), 392.61 ± 50.57 N (A5), 317.94 ± 30.05 N (A7), and 292.74 ± 37.15 N (A9). The fracture load of group N5 was significantly higher than those of group N7 and N9 (P<.017). Consequently, the fracture load of group A5 was also significantly higher than those of group A7 and A9 (P<.05). After artificial aging, the fracture load was significantly decreased in all groups with various preparation depths (P<.05). CONCLUSION The fracture load of a single anterior implant restored with lithium disilicate crown on zirconia abutment with titanium insert differed depending on the preparation depths. After 5-year artificial aging, the fracture loads of all preparation groups decreased significantly. PMID:26140169
Toda, Ikuko
2007-01-01
Dry eye is one of the most common complications after laser-assisted in situ keratomileusis (LASIK). The clinical signs of post-LASIK dry eye include positive vital staining of ocular surface, decreased tear film breakup time and Schirmer test, reduced corneal sensitivity, and decreased functional visual acuity. The symptoms and signs last at least 1 month after LASIK. Although the mechanisms for developing post-LASIK dry eye are not completely understood, loss of corneal innervation by flap-making may affect the reflex loops of the corneal-lacrimal gland, corneal-blinking, and blinking-meibomian gland, and blinking-meibomian gland, resulting in decreased aqueous and lipid tear secretion and mucin expression. As LASIK enhancement by flap-lifting induces less dry eye symptoms and signs than first surgery, it is suggested that other factors rather than loss of neurotrophic effect may be involved in the mechanisms of post-LASIK dry eye. The treatments of dry eye include artificial tears, topical cyclosporine, hot compress, punctal plugs, and autologous serum eye drops. For patients with severe preoperative dry eye, a combination of punctal plugs and serum eye drops is required to be used before surgery.
Traumatic Tear of the Latissimus Dorsi Myotendinous Junction
Friedman, Michael V.; Stensby, J. Derek; Hillen, Travis J.; Demertzis, Jennifer L.; Keener, Jay D.
2015-01-01
A case of a latissimus dorsi myotendinous junction strain in an avid CrossFit athlete is presented. The patient developed acute onset right axillary burning and swelling and subsequent palpable pop with weakness while performing a “muscle up.” Magnetic resonance imaging examination demonstrated a high-grade tear of the right latissimus dorsi myotendinous junction approximately 9 cm proximal to its intact humeral insertion. There were no other injuries to the adjacent shoulder girdle structures. Isolated strain of the latissimus dorsi myotendinous junction is a very rare injury with a scarcity of information available regarding its imaging appearance and preferred treatment. This patient was treated conservatively and was able to resume active CrossFit training within 3 months. At 6 months postinjury, he had only a mild residual functional deficit compared with his preinjury level. PMID:26502450
Wallerstein, Avi; Jackson, W Bruce; Chambers, Jeffrey; Moezzi, Amir M; Lin, Hugh; Simmons, Peter A
2018-01-01
Purpose To compare the efficacy and safety of a preservative-free, multi-ingredient formulation of carboxymethylcellulose 0.5%, hyaluronic acid 0.1%, and organic osmolytes (CMC-HA), to preservative-free carboxymethylcellulose 0.5% (CMC) in the management of postoperative signs and symptoms of dry eye following laser-assisted in situ keratomileusis (LASIK). Methods This was a double-masked, randomized, parallel-group study conducted in 14 clinical centers in Canada and Australia. Subjects with no more than mild dry eye instilled CMC-HA or CMC for 90 days post-LASIK. Ocular Surface Disease Index© (OSDI; primary efficacy measure), corneal staining, tear break-up time (TBUT), Schirmer’s test, acceptability/tolerability surveys, and visual acuity were assessed at screening and days 2, 10, 30, 60, and 90 post-surgery. Safety analyses included all enrolled. Results A total of 148 subjects (CMC-HA, n=75; CMC, n=73) were enrolled and assigned to receive treatment, and 126 subjects completed the study without any protocol violations. Post-LASIK, dry eye signs/symptoms peaked at 10 days. OSDI scores for both groups returned to normal with no differences between treatment groups at day 90 (P=0.775). Corneal staining, Schirmer’s test, TBUT, and survey results were comparable. Higher mean improvements in uncorrected visual acuity were observed in the CMC-HA group at all study visits, reaching statistical significance at day 30 (P=0.013). Both treatments were well tolerated. Conclusion CMC-HA-containing artificial tears relieved post-LASIK ocular dryness as well as CMC alone, and demonstrated incremental benefit in uncorrected vision, with a favorable safety profile. Results support use of CMC-HA eye drops to reduce signs and symptoms of ocular dryness post-LASIK. PMID:29765198
Mukhopadhyay, Somnath; Sen, Swarnali; Datta, Himadri
2015-01-01
To compare the role of topically applied serum therapy with preservative-free artificial tear (AT) drops in patients with moderate to severe dry eye in Hansen's disease along with change in tear protein profile. 144 consecutive patients were randomly divided into three groups. After a baseline examination of clinical parameters, each of the patients received designated modality of topical therapy six times a day for 6 weeks. Post-treatment documentation of clinical parameters was done at 6 weeks, and then at 12 weeks after discontinuation of topical therapy. Analysis of three tear proteins using gel electrophoresis (sodium dodecyl sulfate polyacrylamide gel electrophoresis) was done at baseline, at the first and second post-treatment visits. In the cord blood serum (CBS) group, except for McMonnies score and staining score, all other clinical parameters showed continued improvement in the first and second post-treatment analyses. In the autologous serum (ALS) group, all the clinical parameters except Schirmer's I showed significant improvement in the first post-treatment analysis .This was sustained at a significant level in the second analysis except for tear film break-up time (TBUT) and conjunctival impression cytology grading. In the AT group, all the parameters improved at a non-significant level except for TBUT in the first analysis. In the next analysis, apart from McMonnies score and TBUT, other clinical parameters did not improve. In the ALS and CBS groups, tear lysozyme, lactoferrin levels improved in both post-treatment measurements (statistically insignificant).Total tear protein continued to increase at statistically significant levels in the first and second post-treatment analyses in the CBS group and at a statistically insignificant level in the ALS group. In the AT group, the three tear proteins continued to decrease in both the analyses. In moderate to severe dry eye in Hansen's disease, serum therapy in comparison with AT drops, improves clinical parameters and causes betterment in tear protein profile. CTRI/2013/07/003802. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Jacobi, Christina; Kruse, Friedrich E; Cursiefen, Claus
2012-12-01
The aim of this prospective, randomized, clinical, single-center study was to compare the safety and efficacy of 2 ocular surface lubricant eye drops: preservative-free hydroxypropyl (HP)-Guar (SYSTANE UD(®)) eye drops versus preservative-free Tamarindus indica seed polysaccharide (TSP) 1% (VISINE INTENSIV 1% EDO(®)) eye drops. Fifty-six eyes of 28 patients with moderate keratoconjunctivitis sicca (DEWS severity level 2) were enrolled in the trial. Patients were randomized for 2 treatment groups (SYSTANE UD eye drops vs. VISINE INTENSIV 1% EDO eye drops). The eye drops in both groups were applied 5 times per day for 3 months. Statistical analyses were performed using Statistica™ software (Mann-Whitney U-test and Wilcoxon test). P-Values<0.05 were considered significant. After 3 months of treatment the patients of both groups had subjective benefit in the relief of symptoms of dry eye disease evaluated by the Ocular Surface Disease Index (OSDI) questionnaire score. Patients treated with HP-Guar and TSP showed improvements in tear film stability measured by tear break-up time (TBUT), which are statistically significant in the HP-Guar group (P=0.02). The results of this clinical trial show improvements of symptoms and signs in patients with moderate dry eye after the consistent use of preservative-free HP-Guar and TSP lubricant eye drops. Both artificial tear formulations produce amelioration in tear film stability improving eye conditions and patient quality of life. HP-Guar seems to be slightly more effective in improving ocular surface protection by decreasing tear film evaporation.
Rolando, Maurizio; Cantera, Emilia; Mencucci, Rita; Rubino, Pierangela; Aragona, Pasquale
2018-04-01
To describe a standard approach to manage tear dysfunction (TD), in order to obtain a clinically favourable outcome. TD is a highly prevalent, yet largely underdiagnosed, condition that affects from 5 to 30% of the population above 50 years old. Left untreated, TD is associated with eye discomfort and ocular surface disease, substantially affecting quality of life. Although the prevalence of this problem is increasing significantly, a standard approach to its prevention and treatment is not available yet. In September 2015, a team of Ocular Surface Italian Experts convened for a roundtable to discuss on the latest knowledge about diagnosis and treatments for TD and the real issues in the management of these patients. The discussion centred on the appropriate definition of TD, proposing a new classification of risk factors and how to identify them, how to make a correct diagnosis choosing the rational therapy (questionnaires, symptoms' time relation, seasonality, low tech diagnostic manoeuvres, specific tests for the detection of tear film disturbances leading to recognition of the level of disease and of the ocular system elements involved), which artificial tear matches the ideal profile for a rational therapy and which questions should be done to the patient. A multi-item flowchart for tear film dysfunction, with point-by-point explanatory guide, to better identify and manage the patient with this disorder is provided. The growing prevalence of TD demands increased attention. An appropriate prevention and a treatment pattern for the patient, combined with greater patient-practitioner interaction, and patient education is offered.
Jiang, Nan; Tamayol, Ali; Ruiz-Esparza, Guillermo U.; Zhang, Yu Shrike; Medina-Pando, Sofía; Gupta, Aditi; Wolffsohn, James S.; Butt, Haider; Khademhosseini, Ali
2017-01-01
The analysis of tear constituents at point-of-care settings has a potential for early diagnosis of ocular disorders such as dry eye disease, low-cost screening, and surveillance of at-risk subjects. However, current minimally-invasive rapid tear analysis systems for point-of-care settings have been limited to assessment of osmolarity or inflammatory markers and cannot differentiate between dry eye subclassifications. Here, we demonstrate a portable microfluidic system that allows quantitative analysis of electrolytes in the tear fluid that is suited for point-of-care settings. The microfluidic system consists of a capillary tube for sample collection, a reservoir for sample dilution, and a paper-based microfluidic device for electrolyte analysis. The sensing regions are functionalized with fluorescent crown ethers, o-acetanisidide, and seminaphtorhodafluor that are sensitive to mono- and divalent electrolytes, and their fluorescence outputs are measured with a smartphone readout device. The measured sensitivity values of Na+, K+, Ca2+ ions and pH in artificial tear fluid were matched with the known ion concentrations within the physiological range. The microfluidic system was tested with samples having different ionic concentrations, demonstrating the feasibility for the detection of early-stage dry eye, differential diagnosis of dry eye sub-types, and their severity staging. PMID:28207920
Moritomo, Hisao; Arimitsu, Sayuri; Kubo, Nobuyuki; Masatomi, Takashi; Yukioka, Masao
2015-02-01
To classify triangular fibrocartilage complex (TFCC) foveal lesions on the basis of computed tomography (CT) arthrography using a radial plane view and to correlate the CT arthrography results with surgical findings. We also tested the interobserver and intra-observer reliability of the radial plane view. A total of 33 patients with a suspected TFCC foveal tear who had undergone wrist CT arthrography and subsequent surgical exploration were enrolled. We classified the configurations of TFCC foveal lesions into 5 types on the basis of CT arthrography with the radial plane view in which the image slices rotate clockwise centered on the ulnar styloid process. Sensitivity, specificity, and positive predictive values were calculated for each type of foveal lesion in CT arthrography to detect foveal tears. We determined interobserver and intra-observer agreements using kappa statistics. We also compared accuracies with the radial plane views with those with the coronal plane views. Among the tear types on CT arthrography, type 3, a roundish defect at the fovea, and type 4, a large defect at the overall ulnar insertion, had high specificity and positive predictive value for the detection of foveal tears. Specificity and positive predictive values were 90% and 89% for type 3 and 100% and 100% for type 4, respectively, whereas sensitivity was 35% for type 3 and 22% for type 4. Interobserver and intra-observer agreement was substantial and almost perfect, respectively. The radial plane view identified foveal lesion of each palmar and dorsal radioulnar ligament separately, but accuracy results with the radial plane views were not statistically different from those with the coronal plane views. Computed tomography arthrography with a radial plane view exhibited enhanced specificity and positive predictive value when a type 3 or 4 lesion was identified in the detection of a TFCC foveal tear compared with historical controls. Diagnostic II. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Arthroscopic treatment options for irreparable rotator cuff tears of the shoulder
Anley, Cameron M; Chan, Samuel KL; Snow, Martyn
2014-01-01
The management of patients with irreparable rotator cuff tears remains a challenge for orthopaedic surgeons with the final treatment option in many algorithms being either a reverse shoulder arthroplasty or a tendon transfer. The long term results of these procedures are however still widely debated, especially in younger patients. A variety of arthroscopic treatment options have been proposed for patients with an irreparable rotator cuff tear without the presence of arthritis of the glenohumeral joint. These include a simple debridement with or without a biceps tenotomy, partial rotator cuff repair with or without an interval slide, tuberplasty, graft interposition of the rotator cuff, suprascapular nerve ablation, superior capsule reconstruction and insertion of a biodegradable spacer (Inspace) to depress the humeral head. These options should be considered as part of the treatment algorithm in patients with an irreparable rotator cuff and could be used as either as an interim procedure, delaying the need for more invasive surgery in the physiologically young and active, or as potential definitive procedures in the medically unfit. The aim of this review is to highlight and summarise arthroscopic procedures and the results thereof currently utilised in the management of these challenging patients. PMID:25405083
Driver's side curtain air bag-related globe rupture.
Porter, Ashley J; Hayes, Rylan; Lee, Lawrence; O'Hagan, Stephen
2018-06-04
A 35-year-old man presented after a high-speed motor vehicle accident and the driver's side curtain air bag causing blunt force trauma rupturing his right globe. The tangential force of the air bag resulted in an unusual arcuate horseshoe-shaped rupture through the lateral rectus insertion, causing avulsion of the muscle and tearing the sclera, with the apices of the tear extending anteriorly towards the limbus. Repair of the globe rupture was undertaken, and secondary vitrectomy revealed that the scleral tear had not involved the retina abutting the ora serrata. Silicone oil tamponade was used to fill the globe and the postoperative best corrected vision was 6/9. This is the first reported case of a ruptured globe caused by a side curtain air bag, resulting in a uniquely shaped arcuate scleral wound combined with lateral rectus avulsion, not associated with rhegmatogenous retinal damage, and is the first air bag-related globe rupture with scleral involvement to report a final best-corrected visual acuity better than 6/60. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Si, Wen; Li, Zhan-Ting; Hou, Jun-Li
2014-04-25
Three new artificial transmembrane channel molecules have been designed and synthesized by attaching positively charged Arg-incorporated tripeptide chains to pillar[5]arene. Fluorescent and patch-clamp experiments revealed that voltage can drive the molecules to insert into and leave from a lipid bilayer and thus switch on and off the transport of K(+) ions. One of the molecules was found to display antimicrobial activity toward Bacillus subtilis with half maximal inhibitory concentration (IC50 ) of 10 μM which is comparable to that of natural channel-forming peptide alamethicin. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Low back pain: conservative treatment with artificial shock absorbers.
Wosk, J; Voloshin, A S
1985-03-01
A new method of conservative treatment for low back pain (LBP) was studied by follow-up investigation of 382 patients during the last five years. The attempt to reduce repetitive impulsive intervertebral impact in the troublesome S1-L5-4 area by significant improvement of the foot's attenuational capacity through artificial viscoelastic shock absorbing was prompted by the authors' work on decreased capability of LBP spines to attenuate axially propagated walking stresses. Viscoelastic shoe inserts were used in addition to light flexible shoes as artificial shock absorbing devices. Maximal amplitudes of bone oscillation during walking were reduced by about 40% by the viscoelastic inserts. Rapid and surprisingly significant improvement of pain syndrome and patient mobility occurred in about 80% of the patients. The accelerographic patterns recorded on a sacrum of patient with LBP were unusual for a healthy subject; they usually disappeared after treatment in LBP cases. Results suggested that poor walking impact attenuation was a true cause for prolonging intervertebral structures overstrain and consequent degeneration. It seemed logical that as spine damage could be explained primarily by prolonged impulsive overstrain, treatment must include viscoelastic inserts which increase foot shock absorbing capacity and help cushion the spine.
Antimicrobial role of human meibomian lipids at the ocular surface.
Mudgil, Poonam
2014-10-14
Human meibomian lipids form the outermost lipid layer of the tear film and serve many important functions to maintain its integrity. Although not investigated earlier, these lipids may have antimicrobial properties that help in strengthening the innate host defense of tears at the ocular surface. The aim of this study was to investigate the antimicrobial role of human meibomian lipids. Ocular pathogenic bacteria, Staphylococcus aureus 31, Pseudomonas aeruginosa 19, Pseudomonas aeruginosa 20, and Serratia marcescens 35, were grown in the presence and absence of human meibomian lipids in an artificial tear solution at the physiological temperature. Viable counts were obtained to note the number of bacteria surviving the treatment with meibomian lipids. Bacterial cells were imaged using scanning electron microscopy to observe the damages caused by meibomian lipids. Viable count results showed that in the presence of meibomian lipids, growth of all bacteria was considerably lower. Scanning electron microscopy showed that meibomian lipids caused extensive cellular damage to bacteria as manifested in smaller size, loss of aggregation, abnormal phenotype, cellular distortion, damaged cell wall, and cell lysis. This is the first-ever report of the antimicrobial role of human meibomian lipids. These lipids possess antimicrobial properties against both Gram-positive and Gram-negative bacteria and are involved in the innate host defense of tears in protecting the ocular surface against microbial pathogens. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Aziz, Mina Sr; Tsuji, Matthew Rs; Nicayenzi, Bruce; Crookshank, Meghan C; Bougherara, Habiba; Schemitsch, Emil H; Zdero, Radovan
2014-05-01
During orthopedic surgery, screws are inserted by "subjective feel" in humeri for fracture fixation, that is, stopping torque, while trying to prevent accidental over-tightening that causes screw-bone interface failure, that is, stripping torque. However, no studies exist on stopping torque, stripping torque, or stopping/stripping torque ratio in human or artificial humeri. This study evaluated five types of humeri, namely, human fresh-frozen (n = 19), human embalmed (n = 18), human dried (n = 15), artificial "normal" (n = 13), and artificial "osteoporotic" (n = 13). An orthopedic surgeon used a torque screwdriver to insert 3.5-mm-diameter cortical screws into humeral shafts and 6.5-mm-diameter cancellous screws into humeral heads by "subjective feel" to obtain stopping and stripping torques. The five outcome measures were raw and normalized stopping torque, raw and normalized stripping torque, and stopping/stripping torque ratio. Normalization was done as raw torque/screw-bone interface area. For "gold standard" fresh-frozen humeri, cortical screw tests yielded averages of 1312 N mm (raw stopping torque), 30.4 N/mm (normalized stopping torque), 1721 N mm (raw stripping torque), 39.0 N/mm (normalized stripping torque), and 82% (stopping/stripping torque ratio). Similarly, fresh-frozen humeri gave cancellous screw average results of 307 N mm (raw stopping torque), 0.9 N/mm (normalized stopping torque), 392 N mm (raw stripping torque), 1.2 N/mm (normalized stripping torque), and 79% (stopping/stripping torque ratio). Of the five cortical screw parameters for fresh-frozen humeri versus other groups, statistical equivalence (p ≥ 0.05) occurred in four cases (embalmed), three cases (dried), four cases (artificial "normal"), and four cases (artificial "osteoporotic"). Of the five cancellous screw parameters for fresh-frozen humeri versus other groups, statistical equivalence (p ≥ 0.05) occurred in five cases (embalmed), one case (dried), one case (artificial "normal"), and zero cases (artificial "osteoporotic"). Stopping/stripping torque ratios were relatively constant for all groups at 77%-88% (cortical screws) and 79%-92% (cancellous screws). © IMechE 2014.
The Effect of Autologous Platelet Lysate Eye Drops: An In Vivo Confocal Microscopy Study
Fea, Antonio M.; Testa, Valeria; Machetta, Federica; Parisi, Simone; D'Antico, Sergio; Spinetta, Roberta; Fusaro, Enrico; Grignolo, Federico M.
2016-01-01
Purpose. To determine the effectiveness of autologous platelet lysate (APL) eye drops in patients with primary Sjögren syndrome (SS) dry eye, refractory to standard therapy, in comparison with patients treated with artificial tears. We focused on the effect of APL on cornea morphology with the in vivo confocal microscopy (IVCM). Methods. Patients were assigned to two groups: group A used autologous platelet lysate QID, and group B used preservative-free artificial tears QID, for 90 days. Ophthalmological assessments included ocular surface disease index (OSDI), best corrected visual acuity (BCVA), Schirmer test, fluorescein score, and breakup time (BUT). A subgroup of patients in group A underwent IVCM: corneal basal epithelium, subbasal nerves, Langerhans cells, anterior stroma activated keratocytes, and reflectivity were evaluated. Results. 60 eyes of 30 patients were enrolled; in group A (n = 20 patients) mean OSDI, fluorescein score, and BUT showed significant improvement compared with group B (n = 10 patients). The IVCM showed a significant increase in basal epithelium cells density and subbasal nerve plexus density and number and a decrease in Langerhans cells density (p < 0.05). Conclusion. APL was found effective in the treatment of SS dry eye. IVCM seems to be a useful tool to visualize cornea morphologic modifications. PMID:27200376
The Effect of Autologous Platelet Lysate Eye Drops: An In Vivo Confocal Microscopy Study.
Fea, Antonio M; Aragno, Vittoria; Testa, Valeria; Machetta, Federica; Parisi, Simone; D'Antico, Sergio; Spinetta, Roberta; Fusaro, Enrico; Grignolo, Federico M
2016-01-01
Purpose. To determine the effectiveness of autologous platelet lysate (APL) eye drops in patients with primary Sjögren syndrome (SS) dry eye, refractory to standard therapy, in comparison with patients treated with artificial tears. We focused on the effect of APL on cornea morphology with the in vivo confocal microscopy (IVCM). Methods. Patients were assigned to two groups: group A used autologous platelet lysate QID, and group B used preservative-free artificial tears QID, for 90 days. Ophthalmological assessments included ocular surface disease index (OSDI), best corrected visual acuity (BCVA), Schirmer test, fluorescein score, and breakup time (BUT). A subgroup of patients in group A underwent IVCM: corneal basal epithelium, subbasal nerves, Langerhans cells, anterior stroma activated keratocytes, and reflectivity were evaluated. Results. 60 eyes of 30 patients were enrolled; in group A (n = 20 patients) mean OSDI, fluorescein score, and BUT showed significant improvement compared with group B (n = 10 patients). The IVCM showed a significant increase in basal epithelium cells density and subbasal nerve plexus density and number and a decrease in Langerhans cells density (p < 0.05). Conclusion. APL was found effective in the treatment of SS dry eye. IVCM seems to be a useful tool to visualize cornea morphologic modifications.
Combination of hyaluronic acid, carmellose, and osmoprotectants for the treatment of dry eye disease
Mateo Orobia, Antonio José; Saa, Jorge; Ollero Lorenzo, Alberto; Herreras, José María
2018-01-01
Background Dry Eye Disease (DED) is a multifactorial disease, with a high prevalence, that can have a great impact on the quality of life of patients. The first step of treatment includes the use of lacrimal substitutes composed of polymers, possible to associate osmoprotectant agents to the lacrimal substitutes. The aim of this article is to analyze the properties of the combination of hyaluronic acid (HA), carmellose, and osmoprotectors (Optava Fusion®; Allergan, Inc., Irvine, CA, USA) on DED. General considerations on the use of artificial tears are also proposed. Methods A group of ophthalmologists, experts in the management of the ocular surface, analyzed different aspects related to DED; among them, the use of artificial tears in general and the properties of the combination of HA, carmellose, and osmoprotectors, in particular, were discussed. A review of the literature was carried out, which included different articles published in Spanish, English, and French until April 2017. Conclusions DED is a common chronic pathology that usually requires sustained treatment. In addition, the combination of HA, carmellose, and osmoprotectors has proven to be effective in the treatment of symptoms and signs of dry eye by the synergistic action of all its components. This review provides key elements to help ophthalmologists who begin in the management of DED. PMID:29563769
Friedman, Michael V; Stensby, J Derek; Hillen, Travis J; Demertzis, Jennifer L; Keener, Jay D
2015-01-01
A case of a latissimus dorsi myotendinous junction strain in an avid CrossFit athlete is presented. The patient developed acute onset right axillary burning and swelling and subsequent palpable pop with weakness while performing a "muscle up." Magnetic resonance imaging examination demonstrated a high-grade tear of the right latissimus dorsi myotendinous junction approximately 9 cm proximal to its intact humeral insertion. There were no other injuries to the adjacent shoulder girdle structures. Isolated strain of the latissimus dorsi myotendinous junction is a very rare injury with a scarcity of information available regarding its imaging appearance and preferred treatment. This patient was treated conservatively and was able to resume active CrossFit training within 3 months. At 6 months postinjury, he had only a mild residual functional deficit compared with his preinjury level. © 2015 The Author(s).
Gupta, Amit; Rattan, Amulya; Kumar, Sunil; Rathi, Vinita
2017-09-01
A 13-year-old girl, who did not receive any treatment for few hours following Road Traffic Injury (RTI), reported to the Casualty Department and found to have patent airway with clinically normal C spine, air-hunger (RR 42/minute), trachea deviated to left, distended neck veins and absent breath sounds on the right side. The chest X-ray she carried, done immediately after the injury, showed right sided tension pneumothorax. She was put on oxygen at 11 L/minute and an Intercostal chest tube drainage (ICD) was inserted on right side. Her oxygen saturation (40%) failed to improve. ICD bag showed continuous bubbling and air entry remained absent on the right side. An urgent right thoracotomy was done which revealed right main bronchus tear; the tear was repaired using interrupted Prolene ® sutures. Patient recovered well and was discharged 10 days later in a stable condition.
Villacis, Diego; Merriman, Jarrad; Wong, Karlton; Rick Hatch, George F.
2013-01-01
Latissimus dorsi transfer is a well-established method for the treatment of posterosuperior massive irreparable rotator cuff tears. We propose using an arthroscopically assisted technique that avoids insult to the deltoid. With the patient in the lateral decubitus position, an L-shaped incision is made along the anterior belly of the latissimus muscle and then along the posterior axillary line. The latissimus and teres major are identified and separated. The tendon insertion of the latissimus is isolated, and a FiberWire traction suture (Arthrex, Naples, FL) is placed, facilitating dissection of the muscle to the thoracodorsal neurovascular pedicle and subsequent mobilization. The interval deep to the deltoid and superficial to the teres minor is developed into a subdeltoid tunnel for arthroscopic tendon transfer. The latissimus tendon is then transferred and stabilized arthroscopically to the lateral aspect of the infraspinatus and supraspinatus footprints by multiple suture anchors. PMID:23767006
Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos
2017-11-01
In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo
2014-01-01
Background The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis®) for the treatment of dry eye syndrome in rabbits. Methods Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis®-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. Results After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis®-treated group. The AUC0–24 h for rabbit’s tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis®. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis®. Conclusion These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes. PMID:25143728
Aragona, Pasquale; Rania, Laura; Roszkowska, Anna M; Spinella, Rosaria; Postorino, Elisa; Puzzolo, Domenico; Micali, Antonio
2013-09-01
To evaluate the effect of aminoacid enriched artificial tears on the ocular surface of patients with dysfunctional tear syndrome (DTS). Forty patients were divided into two groups: group 1 treated for 90 days with sodium hyaluronate (SH) 0.15% 1 drop × 5 times/day; group 2 treated for 90 days with SH 0.15% + aminoacids mixture 1 drop × 5 times/day. Symptom score questionnaire, tear break-up time (TBUT), corneal fluorescein stain, Shirmer's I test and confocal microscopy were performed at baseline and after 30 and 90 days. Confocal images underwent morphometric analysis. Both treatments improved symptoms after 1 month. Group 2 patients showed at 1 month an improvement of TBUT and corneal stain, maintained throughout the study. Also Shirmer's I test improved after 3 months. In group 1, an improvement of TBUT and corneal stain was observed after 3 months. The morphometric analysis of confocal images demonstrated at month 1 an improvement of nerve tortuosity in group 2; after 3 months both groups showed a significant improvement versus baseline. The epithelium showed, in both groups, a reduction in hyperreflective large cells starting from 1 month; the area of the cells was significantly reduced after 3 months, with a significant higher reduction in group 2. The perineural stromal opacity was significantly increased after 3 months, particularly in group 2. This is the first study addressing corneal changes after amino acids administration in a DTS population. The treatment with amino acids enriched SH can be considered a useful tool in the treatment of DTS. © 2013 The Authors Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.
Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo
2014-01-01
The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis) for the treatment of dry eye syndrome in rabbits. Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis-treated group. The AUC₀₋₂₄ h for rabbit's tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis. These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes.
Adsorption of human tear lipocalin to human meibomian lipid films.
Millar, Thomas J; Mudgil, Poonam; Butovich, Igor A; Palaniappan, Chendur K
2009-01-01
Tear lipocalin (Tlc) is a major lipid binding protein in tears and is thought to have an important role in stabilizing the Meibomian lipid layer by transferring lipids to it from the aqueous layer or ocular surface, or by adsorbing to it directly. These possible roles have been investigated in vitro using human Tlc. Tlc was purified from human tears by size exclusion chromatography followed by ion exchange chromatography. Three additional samples of the Tlc were prepared by lipidation, delipidation, and relipidation. The lipids extracted from the purified Tlc were analyzed by HPLC-MS followed by fragmentation. Adsorption of these different forms of Tlc to a human Meibomian lipid film spread on the surface of an artificial tear buffer in a Langmuir trough were observed by recording changes in the pressure with time (Pi-T profile) and monitoring the appearance of the film microscopically. These results were compared with similar experiments using a bovine Meibomian lipid film. The results indicated that Tlc binds slowly to a human Meibomian lipid film compared with lysozyme or lactoferrin, even at 37 degrees C. The adsorption of Tlc to a human Meibomian lipid film was very different from its adsorption to a bovine Meibomian lipid film, indicating the nature of the lipids in the film is critical to the adsorption process. Similarly, the different forms of Tlc had quite distinct adsorption patterns, as indicated both by changes in Pi-T profiles and the microscopic appearance of the films. It was concluded that human Tlc was capable of adsorbing to and penetrating into a Meibomian lipid layer, but this process is very complex and depends on both the types of lipids bound to Tlc and the lipid complement comprising the Meibomian lipid film.
Adsorption of Human Tear Lipocalin to Human Meibomian Lipid Films
Millar, Thomas J.; Mudgil, Poonam; Butovich, Igor A.; Palaniappan, Chendur K.
2009-01-01
Purpose Tear lipocalin (Tlc) is a major lipid binding protein in tears and is thought to have an important role in stabilizing the Meibomian lipid layer by transferring lipids to it from the aqueous layer or ocular surface, or by adsorbing to it directly. These possible roles have been investigated in vitro using human Tlc. Methods Tlc was purified from human tears by size exclusion chromatography followed by ion exchange chromatography. Three additional samples of the Tlc were prepared by lipidation, delipidation, and relipidation. The lipids extracted from the purified Tlc were analyzed by HPLC-MS followed by fragmentation. Adsorption of these different forms of Tlc to a human Meibomian lipid film spread on the surface of an artificial tear buffer in a Langmuir trough were observed by recording changes in the pressure with time (∏-T profile) and monitoring the appearance of the film microscopically. These results were compared with similar experiments using a bovine Meibomian lipid film. Results The results indicated that Tlc binds slowly to a human Meibomian lipid film compared with lysozyme or lactoferrin, even at 37°C. The adsorption of Tlc to a human Meibomian lipid film was very different from its adsorption to a bovine Meibomian lipid film, indicating the nature of the lipids in the film is critical to the adsorption process. Similarly, the different forms of Tlc had quite distinct adsorption patterns, as indicated both by changes in ∏-T profiles and the microscopic appearance of the films. Conclusions It was concluded that human Tlc was capable of adsorbing to and penetrating into a Meibomian lipid layer, but this process is very complex and depends on both the types of lipids bound to Tlc and the lipid complement comprising the Meibomian lipid film. PMID:18757516
Pharmacokinetic Studies of Sustained-Release Depot of Dexamethasone in Beagle Dogs.
Blizzard, Charles; Desai, Ankita; Driscoll, Arthur
2016-11-01
To examine the pharmacokinetic characteristics of sustained-release dexamethasone depots in two separate canine studies. Dexamethasone depots loaded with a clinically representative (0.4 mg) dose (DEXTENZA™; Ocular Therapeutix) or an elevated (0.7 mg) dose were inserted into the canaliculi of beagle eyes (n = 37 and n = 34, respectively). Tear fluid was collected for pharmacokinetic analysis of dexamethasone in both studies at predetermined time points. Explanted 0.4 mg depots were collected weekly to measure remaining drug level. Clinical observations and ophthalmic examinations were performed in both studies at each visit. The 0.4 mg depots released a median 308 μg by day 15 and tapered to complete drug release by day 28. Median dexamethasone tear fluid concentrations in the 0.4 mg study group decreased from 2,805 ng/mL at day 7 to 0 ng/mL on day 28. Median dexamethasone tear fluid concentrations in the 0.7 mg study group decreased from 4,370 ng/mL at 6 h post insertion to 830 ng/mL on day 35. Mean ± standard deviation intraocular pressures in the 0.4 and 0.7 mg study groups were 20.7 ± 2.8 and 19.0 ± 4.1 mmHg at baseline, respectively, and demonstrated no meaningful change (20.5 ± 3.0 and 20.6 ± 2.9 mmHg, respectively) over the studies' durations. No ocular toxicities were attributed to the dexamethasone depot. Sustained-release dexamethasone produced no identifiable ocular toxicity in this animal model, and pharmacokinetics demonstrated a sustained and tapered drug release over 28 days at a 0.4 mg dose and exceeded 35 days at a 0.7 mg dose.
A novel nanoscale-dispersed eye ointment for the treatment of dry eye disease
NASA Astrophysics Data System (ADS)
Zhang, Wenjian; Wang, Yan; Lee, Benjamin Tak Kwong; Liu, Chang; Wei, Gang; Lu, Weiyue
2014-03-01
A novel nanoscale-dispersed eye ointment (NDEO) for the treatment of severe evaporative dry eye has been successfully developed. The excipients used as semisolid lipids were petrolatum and lanolin, as used in conventional eye ointment, which were coupled with medium-chain triglycerides (MCT) as a liquid lipid; both phases were then dispersed in polyvinyl pyrrolidone solution to form a nanodispersion. Single-factor experiments were conducted to optimize the formulations. A transmission electron micrograph showed that the ointment matrix was entrapped in the nanoemulsion of MCT, with a mean particle size of about 100 nm. The optimized formulation of NDEO was stable when stored for six months at 4 °C, and demonstrated no cytotoxicity to human corneal epithelial cells when compared with commercial polymer-based artificial tears (Tears Natural® Forte). The therapeutic effects of NDEO were evaluated on a mouse model with ‘dry eye’. Both the tear break-up time and fluorescein staining demonstrated therapeutic improvement, displaying a trend of positive correlation with higher concentrations of ointment matrix in the NDEO formulations compared to a marketed product. Histological evaluation demonstrated that the NDEO restored the normal corneal and conjunctival morphology and is safe for ophthalmic application.
Blood, men and tears: keeping IUDs in place in Bangladesh.
Bradley, Janet E; Alam, Mahboob-E-; Shabnam, Fatema; Beattie, Tara S H
2009-06-01
The Intra-Uterine Device (IUD) is an effective method of contraception, but in Bangladesh is associated with high levels of discontinuation within the first year. This study involved data collection from a retrospective cohort of women who had an IUD inserted 12 months earlier. In the cohort, 330 women were interviewed to identify factors associated with discontinuation. Later, 20 women, of the 103 who reported discontinuing because of excessive menstrual bleeding, were interviewed again and in depth about these issues. Of 330 women who had an IUD inserted, 47.3% had discontinued use one year post-insertion. In univariate and multivariate analyses, IUD discontinuation was strongly associated with side-effects (heavier periods; abdominal pain) and spousal factors (not discussing IUD with husband pre-insertion), but not with service delivery factors. In-depth interviews with women who reported excessive blood loss as the main reason for discontinuation found a doubling of both menstrual days and blood loss after IUD insertion. In Bangladesh, women cannot pray, have sexual intercourse, perform household tasks or participate in community activities during menstruation. Thus, women with menstrual side-effects faced serious physical, social and psychological challenges that made continuation difficult. Among those who discontinued, spouses were generally unsupportive and sometimes abusive, particularly when not involved in the decision to use the IUD.
Ocular allergy and dry eye syndrome.
Bielory, Leonard
2004-10-01
Ocular allergy is a common clinical disorder that includes dry eye syndrome in its differential diagnosis. While ocular allergy treatments have continued to evolve since the early 1990s when the new prescription topical agents became available, there have been no major advances in the treatment of dry eye syndrome other than changes in the chemical structures of various artificial tear formulations. This review is timely and relevant due to the recent FDA approval of several new agents for the treatment of dry eye syndrome. The literature reviewed brings the practicing allergist/clinical immunologist up to date on the recent understanding that T-cell activation plays a key role in dry eye syndrome immunopathophysiology. In addition, the parallel novel treatment developments are discussed, including new formulations for tear substitutes, topical cyclosporine A and purinergic receptor (P2Y2) agonists. The recent developments bode well for patients who are referred for ocular allergy, including dry eye syndrome. A new formulation for a tear substitute that generates a 'soft gel' covering the ocular surface (in situ) is ideal for early forms of dry syndrome, while topical cyclosporine is the first new real prescription treatment for patients with moderate to severe forms of dry eye. Another potential agent to revolutionize the treatment of various disorders is based on the discovery of the purinergic receptor agonists. This is not only relevant for the production of mucin and the change in tear fluid content, but it may also have implications for other sinopulmonary disorders such as cystic fibrosis and chronic sinusitis.
Shariyate, Mohammad J; Kachooei, Amir R; Ebrahimzadeh, Mohammad H
2017-11-01
The patient was a 61-year-old female with massive rotator cuff tear who had no history of smoking, COPD, asthma, or other pulmonary diseases. Four hours following shoulder arthroscopy, the patient developed progressive dyspnea, which was diagnosed as pneumothorax with subcutaneous emphysema extending to the neck and face. Chest tube was inserted promptly. The patient was discharged with a good condition after 7 days. Follow up of the patient for the next 3 months was uneventful.
Seto, Song P; Parks, Akia N; Qiu, Yongzhi; Soslowsky, Louis J; Karas, Spero; Platt, Manu O; Temenoff, Johnna S
2015-09-01
While overuse of the supraspinatus tendon is a leading factor in rotator cuff injury, the underlying biochemical changes have not been fully elucidated. In this study, torn human rotator cuff (supraspinatus) tendon tissue was analyzed for the presence of active cathepsin proteases with multiplex cysteine cathepsin zymography. In addition, an overuse injury to supraspinatus tendons was induced through downhill running in an established rat model. Histological analysis demonstrated that structural damage occurred by 8 weeks of overuse compared to control rats in the region of tendon insertion into bone. In both 4- and 8-week overuse groups, via zymography, there was approximately a 180% increase in cathepsin L activity at the insertion region compared to the controls, while no difference was found in the midsubstance area. Additionally, an over 400% increase in cathepsin K activity was observed for the insertion region of the 4-week overused tendons. More cathepsin K and L immunostaining was observed at the insertion region of the overuse groups compared to controls. These results provide important information on a yet unexplored mechanism for tendon degeneration that may operate alone or in conjunction with other proteases to contribute to chronic tendinopathy.
Seto, Song P.; Parks, Akia N.; Qiu, Yongzhi; Soslowsky, Louis J.; Karas, Spero; Platt, Manu O.; Temenoff, Johnna S.
2015-01-01
While overuse of the supraspinatus tendon is a leading factor in rotator cuff injury, the underlying biochemical changes have not been fully elucidated. In this study, torn human rotator cuff (supraspinatus) tendon tissue was analyzed for the presence of active cathepsin proteases with multiplex cysteine cathepsin zymography. In addition, an overuse injury to supraspinatus tendons was induced through downhill running in an established rat model. Histological analysis demonstrated that structural damage occurred by 8 weeks of overuse compared to control rats in the region of tendon insertion into bone. In both 4- and 8-week overuse groups, via zymography, there was approximately a 180% increase in cathepsin L activity at the insertion region compared to the controls, while no difference was found in the midsubstance area. Additionally, an over 400% increase in cathepsin K activity was observed for the insertion region of the 4-week overused tendons. More cathepsin K and L immunostaining was observed at the insertion region of the overuse groups compared to controls. These results provide important information on a yet unexplored mechanism for tendon degeneration that may operate alone or in conjunction with other proteases to contribute to chronic tendinopathy. PMID:25558848
Dry Eye Management: Targeting the Ocular Surface Microenvironment.
Zhang, Xiaobo; M, Vimalin Jeyalatha; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo; Li, Wei
2017-06-29
Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment.
Dry Eye Management: Targeting the Ocular Surface Microenvironment
Zhang, Xiaobo; Jeyalatha M, Vimalin; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo
2017-01-01
Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment. PMID:28661456
New insights into the diagnosis and treatment of dry eye.
Dogru, Murat; Tsubota, Kazuo
2004-04-01
Over the past decade, numerous advances have been made in relation to dry eye diagnostic markers, technologies, and treatment options. The mainstay of treatment of dry eye is the use of artificial tear solutions and punctum plugs. A goal is the development of agents that provide symptomatic treatment and, at the same time, improve ocular surface keratinization. It is the authors' opinion that the functional visual acuity tester and the new tear stability analysis system will be widely used to improve diagnosis and evaluate treatment outcomes in KCS. Advances in treatment will utilize anti-inflammatory agents, immune suppressants such as Cyclosporin A and FK-506, growth hormones, androgens, topical mucins and ocular surface stimulating drugs, like INS365. Although aqueous-deficient dry eye is most commonly not associated with Sjogren syndrome (SS), aqueous-deficient dry eye is often most severe in patients with SS; thus, this article focuses mainly on SS-associated dry eye.
Direct measurement of hoop strains in the intact and torn human medial meniscus.
Jones, R Spencer; Keene, G C R; Learmonth, D J A; Bickerstaff, D; Nawana, N S; Costi, J J; Pearcy, M J
1996-07-01
OBJECTIVE: To measure the circumferential or hoop strains generated in the medial meniscus during loading of the knee joint and to examine the effect of longitudinal and radial tears in the meniscus on these strain values. DESIGN: An in vitro investigation measuring the circumferential strains in the medial menisci of cadaveric human knees as they were loaded in a materials testing machine. BACKGROUND: The menisci transmit approximately 50% of the load through the knee, the rest being transmitted by direct contact of the articular cartilage. Damage to the menisci will alter the pattern of load transmission as will meniscectomy. This study examined the changes in the mechanics of the meniscus in situ as a result of simulated tears to assess the effect of its load carrying capacity and the implications of surgery to remove part or all of a damaged meniscus. METHODS: Nineteen human cadaveric knees were tested. Windows were made in the joint capsule and strain gauges inserted into the anterior, middle and posterior sections of the medial meniscus. The knees were then loaded to three times body weight at speeds of 50 and 500 mm/min, with the knee joint at 0 degrees and 30 degrees of flexion. The tests were repeated following the creation of a longitudinal or a radial tear in the meniscus. RESULTS: The intact menisci showed significantly less strain in the posterior section compared to the anterior and middle sections (P < 0.003, with strains of 1.54%, 2.86% and 2.65% respectively). With a longitudinal tear this pattern changed with strains decreasing anteriorly and increasing posteriorly. There were also significant differences at different angles of knee joint flexion not seen in the intact meniscus. 50% radial tears reduced the strains anteriorly whilst a complete radial tear completely defunctioned the meniscus. CONCLUSIONS: This study has shown that there are significantly different hoop strains produced in different sections of the medial meniscus under load and the patterns of strain distribution are disturbed by meniscal tears. RELEVANCE: These results provide important data for mathematical models which must include non-uniform behaviour. They also have implications for the surgical management of torn menisci. Undamaged portions should be preserved and the integrity of the circumferential fibres maintained to ensure the menisci retain a load bearing capability.
Technique of laser chromosome welding for chromosome repair and artificial chromosome creation.
Huang, Yao-Xiong; Li, Lin; Yang, Liu; Zhang, Yi
2018-04-01
Here we report a technique of laser chromosome welding that uses a violet pulse laser micro-beam for welding. The technique can integrate any size of a desired chromosome fragment into recipient chromosomes by combining with other techniques of laser chromosome manipulation such as chromosome cutting, moving, and stretching. We demonstrated that our method could perform chromosomal modifications with high precision, speed and ease of use in the absence of restriction enzymes, DNA ligases and DNA polymerases. Unlike the conventional methods such as de novo artificial chromosome synthesis, our method has no limitation on the size of the inserted chromosome fragment. The inserted DNA size can be precisely defined and the processed chromosome can retain its intrinsic structure and integrity. Therefore, our technique provides a high quality alternative approach to directed genetic recombination, and can be used for chromosomal repair, removal of defects and artificial chromosome creation. The technique may also have applicability on the manipulation and extension of large pieces of synthetic DNA.
Richard N. Conner; Daniel Saenz; D. Craig Rudolph; Robert N. Coulson
1998-01-01
Southern pine beetle (Dendroctonus frontalis) infestation is the major cause of mortality for red-cockaded woodpecker (Picoides borealis) cavity trees in loblolly (Pinus taeda) and shortleaf (P. echinata) pines. Recent intensive management for red-cockaded woodpeckers includes the use of artificial cavity inserts. Between 1991 and 1996 the authors examined southern...
Artificial dielectric polarizing-beamsplitter and isolator for the terahertz region.
Mendis, Rajind; Nagai, Masaya; Zhang, Wei; Mittleman, Daniel M
2017-07-19
We demonstrate a simple and effective strategy for implementing a polarizing beamsplitter for the terahertz spectral region, based on an artificial dielectric medium that is scalable to a range of desired frequencies. The artificial dielectric medium consists of a uniformly spaced stack of metal plates, which is electromagnetically equivalent to a stacked array of parallel-plate waveguides. The operation of the device relies on both the lowest-order, transverse-electric and transverse-magnetic modes of the parallel-plate waveguide. This is in contrast to previous work that relied solely on the transverse-electric mode. The fabricated polarizing beamsplitter exhibits extinction ratios as high as 42 dB along with insertion losses as low as 0.18 dB. Building on the same idea, we also demonstrate an isolator with non-reciprocal transmission, providing high isolation and low insertion loss at a select design frequency. The performance of our isolator far exceeds that of other experimentally demonstrated terahertz isolators, and indeed, even rivals that of commercially available isolators for optical wavelengths. Because these waveguide-based artificial dielectrics are low loss, inexpensive, and easy to fabricate, this approach offers a promising new route for polarization control of free-space terahertz beams.
Visual problems in young adults due to computer use.
Moschos, M M; Chatziralli, I P; Siasou, G; Papazisis, L
2012-04-01
Computer use can cause visual problems. The purpose of our study was to evaluate visual problems due to computer use in young adults. Participants in our study were 87 adults, 48 male and 39 female, mean aged 31.3 years old (SD 7.6). All the participants completed a questionnaire regarding visual problems detected after computer use. The mean daily use of computers was 3.2 hours (SD 2.7). 65.5 % of the participants complained for dry eye, mainly after more than 2.5 hours of computer use. 32 persons (36.8 %) had a foreign body sensation in their eyes, while 15 participants (17.2 %) complained for blurred vision which caused difficulties in driving, after 3.25 hours of continuous computer use. 10.3 % of the participants sought medical advice for their problem. There was a statistically significant correlation between the frequency of visual problems and the duration of computer use (p = 0.021). 79.3 % of the participants use artificial tears during or after long use of computers, so as not to feel any ocular discomfort. The main symptom after computer use in young adults was dry eye. All visual problems associated with the duration of computer use. Artificial tears play an important role in the treatment of ocular discomfort after computer use. © Georg Thieme Verlag KG Stuttgart · New York.
Labiris, Georgios; Ntonti, Panagiota; Sideroudi, Haris; Kozobolis, Vassilios
2017-01-01
Universal postoperative guidelines for cataract extraction surgery are yet to be introduced. Artificial tears are gaining popularity as an additional integral component of the postoperative regime. The primary objective of this study was to explore the impact of two prevalent artificial tear preparations on postoperative discomfort following cataract extraction surgery. A total of 180 patients that underwent cataract extraction surgery were randomly divided into three groups according to their postoperative regime: a) Study group 1 (SG1) received a fixed combination of tobramycin and dexamethasone (FCTD) quid for 3 weeks and, additionally polyethylene glycol 400/propylene glycol/hydroxypropyl-guar quid, for 6 weeks, b) Study group 2 (SG2) received FCTD quid for 3 weeks and, additionally 0.1% sodium hyaluronate provided in the COMOD® device quid, for 6 weeks, and, c) Control Group (CG) received only FCTD quid for 3 weeks. The following indexes were evaluated at three postoperative checkpoints: 1) Subjective discomfort index (SDI) derived from four direct 10-scale Likert-type questions that were addressed to the patient and pertained to: a) foreign body sensation (FBS), b) blinking discomfort (BD), c) stinging sensation (SS), d) tearing sensation (TS), 2) Tear break-up time (TBUT), 3) Central corneal thickness (CCT) and, 4) Central Corneal Sensitivity (CCS). Both groups showed increased CCT values at the first examination point and reduced CCS values at all examination points. Furthermore, both SGs had better TBUT times at all examination points compared to CG (CG: 8.86 ± 1.08, SG1: 9.59 ± 1.45, CG2: 9.45 ± 1.33, p < 0.05). BD was significantly better in both SGs only at the 1 st week of examination, while SDI values were better until the 3 rd week and only borderline better at 6 th week. Lastly, no significant differences were detected between SGs, regarding all parameters, at all examination points. Polyethylene glycol 400/propylene glycol/hydroxypropyl-guar and 0.1% sodium hyaluronate provided in the COMOD® device seem to be equally efficient in alleviating OSD symptoms following cataract extraction surgery and any of them should be routinely added to the postoperative regime. ClinicalTrials.gov Identifier: https://clinicaltrials.gov/ct2/show/NCT02558218NCT02558218.
López-de la Rosa, Alberto; Pinto-Fraga, José; Blázquez Arauzo, Francisco; Urbano Rodríguez, Rubén; González-García, María J
2017-11-01
To evaluate the safety and efficacy of a new 0.3% hyaluronic acid artificial tear compared with 0.9% saline solution (0.9% NaCl) in moderate-to-severe dry eye patients after 1 month's use. A total of 16 patients with moderate-to-severe dry eye were included in this crossover study. After a 1-week washout period, patients used the experimental (Visaid 0.3%) or control solution (0.9% NaCl), selected randomly, applying three to eight drops daily for a month. After another washout period, patients used the other solution in the same way. Percentage of change (ΔY) was calculated and analyzed for (1) safety variables: visual acuity, intraocular pressure, and ophthalmoscopy evaluation; (2) efficacy variable: Ocular Surface Disease Index (OSDI) questionnaire; and (3) secondary variables: biomicroscopy findings, fluorescein corneal staining, lissamine green conjunctival staining, tear breakup time (TBUT), contrast sensitivity, Schirmer test, and subject satisfaction. There were no significant differences in the safety parameters for either solution. After using Visaid 0.3%, patients showed significant improvements in OSDI score (ΔY: -9.66%±10.90), tarsal hyperemia (ΔY: -16.67%±27.89), corneal staining extension (ΔY: -34.90%±42.41), TBUT (ΔY: 13.98%±26.19), and subjective satisfaction (ΔY: 38.06%±47.06). When using 0.9% NaCl, Schirmer test results were significantly worse (ΔY: -11.47%±19.27). A significant difference between the 2 solutions was found in TBUT (ΔY: 13.98%±26.19 vs. 10.15%±42.34, respectively; P=0.0214). Visaid 0.3% is a safe product with some benefits over 0.9% NaCl in reducing ocular symptoms and improving some ocular signs in patients with moderate-to-severe dry eye.
Zhao, Xinyu; Xia, Song; Chen, Youxin
2017-09-01
The prevalence of dry eye following cataract surgery was reported as high as 55.7%, this acute and iatrogenic disorder urgently required appropriate clinical management. The purpose of this study is to compare the efficacy of diquafosol sodium ophthalmic solution (DQS) and conventional artificial tears (AT) for the treatment of dry eye following cataract surgery. The PubMed, Embase, and the Cochrane Central Register of Controlled Trials were searched from their earliest entries through June 2017 to obtain the studies, which evaluated the efficacy of DQS for patients with dry eye after cataract surgery. The relevant data were analyzed using StataSE 12.0 software. The PRISMA checklist was used as protocol of the meta-analysis and the guideline was followed. The weighted mean difference, relative risk, and their 95% confidence interval were used to assess the strength of the association. The authors identified 21 references of which 4 studies evaluating the efficacy of DQS for patients with dry eye after cataract surgery were included. The dataset consisted of 291 patients of dry eye following cataract surgery (371 postoperative eyes). The pooling result of our study suggested that the DQS could significantly better improve the indices like corneal and conjunctival fluorescein staining scores, tear breakup time, and Schirmer I test than AT (P < .05). Although the scores of symptom questionnaire could not be pooled, the results of each study also proved that DQS could significantly better relieve the symptoms of postoperative dry eye. Based on the available evidence, topical DQS has a superior efficacy than AT in the management of dry eye after cataract surgery; however, further researches with larger sample sizes and focus on indicators such as higher-order aberrations, symptom questionnaire scores, and cost-effective ratio are required to reach a firmer conclusion.
Yılmaz, Uğur; Küçük, Erkut; Koç, Çağdaş; Gökler, Enes
2017-06-01
To investigate dry eye development in the patients receiving systemic retinoic acid therapy and to compare effectiveness of Autologous Serum (AS) and preservative free artificial tear (PFAT) in the patients with dry eye disease. This prospective, crossover, double blind study was conducted on patients who have dry eyes due to systemic isotretinoin treatment for different indications. Patients detected as having dry eye during systemic isotretinoin treatment were included to our study. At baseline, 1 and 2 month of study, detailed ocular examination, best corrected visual acuity measurement, intraocular pressure measurement, and Tear Break-up Time (TBUT) and Schirmer Test (ST) without topical anesthesia were performed. We compared the efficacy of AS and PFAT. To accomplish crossover after the first month, treatment given to each patient was switched to the other treatment. Statistical analysis was measured using SPSS version 20.0. p values of < 0.05 were considered as statistically significant. At the end of the first month, there was a significant improvement for the TBUT test in both AS and PFAT groups compared to baseline (respectively p < 0.001, p < 0.001). TBUT was found to be significantly higher in the AS group compared to the PFAT group at the end of the first month (p < 0.001). At the end of the second month, TBUT was found to be significantly higher in the AS group compared to the PFAT group at the posttreatment time (p < 0.001). There was a significant OSDI score decreasing in both groups compared to that reported previously at the end of the first and second months (respectively p < 0.001, p < 0.001). OSDI score decreasing was more significant in the AS group compared to the PFAT group at both time points (respectively p < 0.001, p < 0.001). AS may be an effective alternative to PFAT in the treatment of dry eye developed during isotretinoin use.
Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.
Kil, Jin-Sang; Park, Jong-Tae
2018-05-01
Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.
Laparoscopic salpingectomy and removal of Essure hysteroscopic sterilisation device: a case series.
Johal, T; Kuruba, N; Sule, M; Mukhopadhyay, S; Raje, G
2018-06-01
Tubal sterilisation using Essure is a minimally invasive technique for permanent contraception, with high rates of patient satisfaction. However, some women subsequently choose removal of the inserts, due to side effects such as pelvic pain, abnormal bleeding, dyspareunia or allergic dermatitis. This case series presents the management of eight women who underwent laparoscopic removal of Essure inserts in conjunction with salpingectomy. We describe our surgical technique, its underlying principles and immediate surgical outcomes. Eight patients were identified as having undergone removal of Essure inserts, via an electronic search of the surgical procedures database. A retrospective review of case records was undertaken. The primary outcome was safety and feasibility of the laparoscopic salpingectomy approach. Secondary outcome measures included implant fracture rate, operative time, blood loss and length of patient stay. All eight women were able to undergo laparoscopic salpingectomy and removal of the Essure inserts without the need for laparotomy or hysterectomy. There were no incidences of fracture or incomplete removal of the insert. Immediate postoperative recovery was uncomplicated in all eight women; the mean length of stay was 17 h. One patient had a small bowel serosal tear attributed to laparoscopic entry. This case series suggests that laparoscopic salpingectomy for removal of Essure inserts is safe and feasible. We acknowledge that the numbers were small. However, consistent use of a laparoscopic approach in these eight patients indicates that this procedure is a feasible and suitable alternative to hysterectomy.
El Allali, Khalid; Sghiri, Abdelmalek; Bouâouda, Hanan; Achaâban, Mohamed Rachid; Ouzir, Mounir; Bothorel, Béatrice; El Mzibri, Mohammed; El Abbadi, Najia; Moutaouakkil, Adnane; Tibary, Ahmed; Pévet, Paul
2018-01-01
To examine a possible control of reproductive seasonality by melatonin, continual-release subcutaneous melatonin implants were inserted 4.5 months before the natural breeding season (October–April) into female camels (Melatonin-treated group). The animals were exposed to an artificial long photoperiod (16L:8D) for 41 days prior to implant placement to facilitate receptivity to the short-day signal that is expected with melatonin implants. The treated and control groups (untreated females) were maintained separately under outdoor natural conditions. Ovarian follicular development was monitored in both groups by transrectal ultrasonography and by plasma estradiol-17β concentrations performed weekly for 8 weeks and then for 14 weeks following implant insertion. Plasma prolactin concentrations were determined at 45 and 15 days before and 0, 14, 28, 56, and 98 days after implant insertion. Plasma melatonin concentration was determined to validate response to the artificial long photoperiod and to verify the pattern of release from the implants. Results showed that the artificial long photoperiod induced a melatonin secretion peak of significantly (P < 0.05) shorter duration (about 2.5 h). Melatonin release from the implants resulted in higher circulating plasma melatonin levels during daytime and nighttime which persisted for more than 12 weeks following implants insertion. Treatment with melatonin implants advanced the onset of follicular growth activity by 3.5 months compared to untreated animals. Plasma estradiol-17β increased gradually from the second week after the beginning of treatment to reach significantly (P < 0.01) higher concentrations (39.2 ± 6.2 to 46.4 ± 4.5 pg/ml) between the third and the fifth week post insertion of melatonin implants. Treatment with melatonin implants also induced a moderate, but significant (P < 0.05) suppressive effect on plasma prolactin concentration on the 28th day. These results demonstrate that photoperiod appears to be involved in dromedary reproductive seasonality. Melatonin implants may be a useful tool to manipulate seasonality and to improve reproductive performance in this species. Administration of subcutaneous melatonin implants during the transition period to the breeding season following an artificial signal of long photoperiod have the potential to advance the breeding season in camels by about 2.5 months. PMID:29594158
An assessment of the complications of the Brantley Scott artificial sphincter.
Heathcote, P S; Galloway, N T; Lewis, D C; Stephenson, T P
1987-08-01
A Brantley Scott artificial sphincter has been inserted into 95 patients since 1981; more than half of the patients had lower urinary tract neuropathy and most of the others post-TUR incontinence. The main problem with the device has been cuff failure (12), which should be resolved by the new "dipped" cuffs. The major surgical complication has been erosion (10), usually associated with infection. Twenty-four patients had variable degrees of incontinence but the artificial sphincter remains the cornerstone of continence control when other methods have failed or are inappropriate.
Full scale model investigation on the acoustical protection of a balcony-like façade device (L).
Tong, Y G; Tang, S K; Yeung, M K L
2011-08-01
The acoustical insertion losses produced by a balcony-like structure in front of a window are examined experimentally. The results suggest that the balcony ceiling is the most appropriate location for the installation of artificial sound absorption for the purpose of improving the broadband insertion loss, while the side walls are found to be the second best. Results also indicate that the acoustic modes of the balcony opening and the balcony cavity resonance in a direction normal to the window could have a great impact on the one-third octave band insertion losses. The maximum broadband road traffic noise insertion loss achieved is about 7 dB.
Dandeniyage, Loshini S; Gunatillake, Pathiraja A; Adhikari, Raju; Bown, Mark; Shanks, Robert; Adhikari, Benu
2017-08-31
Mixed macrodiol based siloxane poly(urethane-urea)s (SiPUU) having number average molecular weights in the range 87-129 kDa/mol were synthesized to give elastomers with high tensile and tear strengths required to fabricate artificial heart valves. Polar functional groups were introduced into the soft segment to improve the poor segmental compatibility of siloxane polyurethanes. This was achieved by linking α,ω-bis(6-hydroxyethoxypropyl) poly(dimethylsiloxane) (PDMS) or poly(hexamethylene oxide) (PHMO) macrodiols with either 4,4'-methylenediphenyl diisocyanate (MDI), hexamethylene diisocyanate (HDI) or isophorone diisocyanate (IPDI) prior to polyurethane synthesis. The hard segment was composed of MDI, and a 1:1 mixture of 1,3-bis(4-hydroxybutyl)-1,1,3,3-tetramethyldisiloxane and 1,2-ethylene diamine. We report the effect of urethane linkers in soft segments on properties of the SiPUU. PHMO linked with either MDI or IPDI produced SiPUU with the highest tensile and tear strengths. Linking PDMS hardly affected the tensile strength; however, the tear strength was improved. The stress-strain curves showed no plastic deformation region typically observed for conventional polyurethanes indicating good creep resistance. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 Wiley Periodicals, Inc.
Dodson, Christopher C; Secrist, Eric S; Bhat, Suneel B; Woods, Daniel P; Deluca, Peter F
2016-03-01
There is a high incidence of anterior cruciate ligament (ACL) injuries among National Football League (NFL) athletes; however, the incidence of reinjury in this population is unknown. This retrospective epidemiological study analyzed all publicly disclosed ACL tears occurring in NFL players between 2010 and 2013 to characterize injury trends and determine the incidence of reinjury. Descriptive epidemiological study. A comprehensive online search identified any NFL player who had suffered an ACL injury from 2010 to 2013. Position, playing surface, activity, and date were recorded. Each player was researched for any history of previous ACL injury. The NFL games database from USA Today was used to determine the incidence of ACL injuries on artificial turf and grass fields. Databases from Pro Football Focus and Pro Football Reference were used to determine the injury rate for each position. NFL players suffered 219 ACL injuries between 2010 and 2013. Forty players (18.3%) had a history of previous ACL injury, with 27 (12.3%) retears and 16 (7.3%) tears contralateral to a previous ACL injury. Five players (2.28%) suffered their third ACL tear. Receivers (wide receivers and tight ends) and backs (linebackers, fullbacks, and halfbacks) had significantly greater injury risk than the rest of the NFL players, while perimeter linemen (defensive ends and offensive tackles) had significantly lower injury risk than the rest of the players. Interior linemen (offensive guards, centers, and defensive tackles) had significantly greater injury risk compared with perimeter linemen. ACL injury rates per team games played were 0.050 for grass and 0.053 for turf fields (P > .05). In this retrospective epidemiological study of ACL tears in NFL players, retears and ACL tears contralateral to a previously torn ACL constituted a substantial portion (18.3%) of total ACL injuries. The significant majority of ACL injuries in players with a history of previous ACL injury were retears. Skilled offensive players and linebackers had the greatest injury risk, and significantly more ACL tears occurred among interior linemen than perimeter linemen. The month of August had the highest incidence of ACL injuries, probably because of expanded roster sizes at that point in the NFL season.
Lorbach, O; Pape, D; Raber, F; Busch, L C; Kohn, D; Kieb, M
2012-11-01
Influence of the initial rotator cuff tear size and of different subregions of the SSP tendon on the cyclic loading behavior of a modified single-row reconstruction compared to a suture-bridging double-row repair. Artificial tears (25 and 35 mm) were created in the rotator cuff of 24 human cadaver shoulders. The reconstructions were performed as a single-row repair (SR) using a modified suture configuration or a suture-bridge double-row repair (DR). Radiostereometric analysis was used under cyclic loading (50 cycles, 10–180 N, 10–250 N) to calculate cyclic displacement in three different planes (anteroposterior (x), craniocaudal (y) and mediolateral (z) level). Cyclic displacement was recorded, and differences in cyclic displacement of the anterior compared to the posterior subregions of the tendon were calculated. In small-to-medium tears (25 mm) and medium-to-large tears (35 mm), significant lower cyclic displacement was seen for the SR-reconstruction compared to the DR-repair at 180 N (p ≤ 0.0001; p = 0.001) and 250 N (p = 0.001; p = 0.007) in the x-level. These results were confirmed in the y-level at 180 N (p = 0.001; p = 0.0022) and 250 N (p = 0.005; p = 0.0018). Comparison of the initial tear sizes demonstrated significant differences in cyclic displacement for the DR technique in the x-level at 180 N (p = 0.002) and 250 N (p = 0.004). Comparison of the anterior versus the posterior subregion of the tendon revealed significant lower gap formation in the posterior compared to the anterior subregions in the x-level for both tested rotator cuff repairs (p ≤ 0.05). The tested single-row repair using a modified suture configuration achieved superior results in three-dimensional measurements of cyclic displacement compared to the tested double-row suture-bridge repair. The results were dependent on the initial rupture size of the rotator cuff tear. Furthermore, significant differences were found between tendon subregions of the rotator cuff with significantly higher gap formation for the anterior compared to the posterior subregions.
Surgical treatment of dry eye syndrome: conjunctival graft of the minor salivary gland.
Güerrissi, Jorge Orlando; Belmonte, Javier
2004-01-01
Despite the availability of efficient tear substitutes, many patients with dry eye syndrome experience severe corneal injuries and a subsequent loss of vision. Surgical techniques using mayor salivary glands to provide a substitute for tears have been reported; with this technique the drainage of saliva goes into the conjunctival fornix, permitting corneal and conjunctival humidification. The authors describe a new surgical approach in which minor salivary glands are autotransplanted into the conjunctival fornix by means of a graft of the intraoral mucosa-transporting salivary glands. This approach was used in a 56-year-old woman with a 2-year history of refractory and pharmacologically untreatable dry eye syndrome caused by Sjögren's syndrome. The right eye had more severe corneal and conjunctival lesions than did the contralateral one, so the treatment was planned in the right eye only. A weekly follow-up during the first 6 months confirmed the significant improvement of dry eye symptoms in the surgically treated eye. Three months after surgery, a biopsy was performed in the minor salivary gland graft, and the histologic findings revealed the presence of glandular acinus, duct with mucin content, and lymphocyte infiltration. The significant improvement obtained in this patient suggests that the secretion from the grafted salivary minor glands was better in promoting homeostasis of the ocular surface than are artificial tears. This may be explained by: (1) The lacrimal and salivary secretions contain biologically active constituents that may protect from infection and promote normal growth epithelium; (2) The secreted mucin is thought to coat the epithelial surface, reducing the high surface tension of the eye wetted by aqueous tears; (3) The thick secretions of the minor gland might act in reducing the evaporation of the underlying tear layer and form a hydrophobic barrier along the lid margin that can retain the lid margin tear string and prevent its flow onto the skin. Minor gland salivary autotransplant is a new surgical technique with effectiveness demonstrated in one patient, but the scientific explanation is not clear; additional experience with more cases could confirm the initial success.
Code of Federal Regulations, 2011 CFR
2011-10-01
... or contact lenses furnished subsequent to each cataract surgery with insertion of an intraocular lens; and (3) Leg, arm, back, and neck braces, and artificial legs, arms, and eyes, including replacements...
NASA Astrophysics Data System (ADS)
Heckmann, Tobias; Haas, Florian; Abel, Judith; Rimböck, Andreas; Becht, Michael
2017-08-01
Dams interrupt the sediment continuum in rivers by retaining the bedload; combined with flow diversion, bedload retention in tributaries and river engineering measures, this causes a bedload deficit leading to changes in river planform and morphodynamics, with potentially detrimental downstream effects. As part of the SedAlp joint project (Sediment management in Alpine basins: integrating sediment continuum, risk mitigation and hydropower), this study investigates changes within a section of the dammed river Isar between the Sylvenstein reservoir and the city of Bad Tölz. We use a multi-method approach on a range of spatial and temporal scales. First, we analysed historical maps and aerial photos to analyse river planform and landcover changes within the river corridor of the whole study area on a temporal scale of over 100 years. Results show that major changes occurred before the construction of the Sylvenstein reservoir, suggesting that present morphodynamics represent the reaction to different disturbances on different time scales. Second, changes in mean bed elevation of cross profiles regularly surveyed by the water authorities are analysed in light of artificial sediment insertion and floods; they are also used to estimate the sediment budget of river reaches between consecutive cross profiles. Results suggest stability and a slight tendency towards incision, especially near the Sylvenstein reservoir; further downstream, the sediment balance was positive. Third, we acquired multitemporal aerial photos using an unmanned aerial vehicle and generated high-resolution digital elevation models to show how sediment artificially inserted in the river corridor is entrained. Depending on the position of the artificial deposits in relation to the channel, the deposits are entrained during floods of different return periods.
[The operative treatment of the degenerative rupture of the anterior tibialis tendon].
Schneppendahl, J; Gehrmann, S V; Stosberg, U; Regenbrecht, B; Windolf, J; Wild, M
2010-05-01
A degenerative tear of the anterior tibial tendon is a rare event compared to other tendons. The purpose of this study was to evaluate the functional results after surgical refixation. In a retrospective study, we report the functional outcome of five consecutive operatively treated patients suffering from a tear close to the insertion site of the anterior tibial tendon. All patients were assessed postoperatively, the AOFAS and Richter scores were obtained and the range of motion in the ankle joint was evaluated. Preoperatively all patients presented with a significant walking impairment due to a reduced active dorsiflexion, so the decision for surgical refixation was made. In all cases an MRI scan was performed preoperatively. Postoperative immobilisation without weight-bearing was done for six weeks. All patients returned to their former activity level, were satisfied with the postoperative result and had a normal gait in the follow-up examination. The range of motion was equal on both sides, the median AOFAS score was 86 and the median Richter score was 90 out of 100. There were no postoperative complications. Untreated tears of the anterior tibial tendon lead to significant impairment of the ankle joint and deformities of the foot. There is no consensus about the treatment with recommendations for operative and non-operative treatment. Various surgical procedures have been described. The surgical reconstruction of the tendon leads to a restored function of the ankle joint and allows a normal gait and is therefore desirable. Due to the loss of function and the good results after surgical treatment in our study, the non-operative treatment is not advisable. Surgical repair of degenerative tears of the anterior tibial tendon leads to very good functional results and high patient satisfaction.
Odon device for instrumental vaginal deliveries: results of a medical device pilot clinical study.
Schvartzman, Javier A; Krupitzki, Hugo; Merialdi, Mario; Betrán, Ana Pilar; Requejo, Jennifer; Nguyen, My Huong; Vayena, Effy; Fiorillo, Angel E; Gadow, Enrique C; Vizcaino, Francisco M; von Petery, Felicitas; Marroquin, Victoria; Cafferata, María Luisa; Mazzoni, Agustina; Vannevel, Valerie; Pattinson, Robert C; Gülmezoglu, A Metin; Althabe, Fernando; Bonet, Mercedes
2018-03-12
A prolonged and complicated second stage of labour is associated with serious perinatal complications. The Odon device is an innovation intended to perform instrumental vaginal delivery presently under development. We present an evaluation of the feasibility and safety of delivery with early prototypes of this device from an early terminated clinical study. Hospital-based, multi-phased, open-label, pilot clinical study with no control group in tertiary hospitals in Argentina and South Africa. Multiparous and nulliparous women, with uncomplicated singleton pregnancies, were enrolled during the third trimester of pregnancy. Delivery with Odon device was attempted under non-emergency conditions during the second stage of labour. The feasibility outcome was delivery with the Odon device defined as successful expulsion of the fetal head after one-time application of the device. Of the 49 women enrolled, the Odon device was inserted successfully in 46 (93%), and successful Odon device delivery as defined above was achieved in 35 (71%) women. Vaginal, first and second degree perineal tears occurred in 29 (59%) women. Four women had cervical tears. No third or fourth degree perineal tears were observed. All neonates were born alive and vigorous. No adverse maternal or infant outcomes were observed at 6-weeks follow-up for all dyads, and at 1 year for the first 30 dyads. Delivery using the Odon device is feasible. Observed genital tears could be due to the device or the process of delivery and assessment bias. Evaluating the effectiveness and safety of the further developed prototype of the BD Odon Device™ will require a randomized-controlled trial. ANZCTR ACTRN12613000141741 Registered 06 February 2013. Retrospectively registered.
Do lipids retard the evaporation of the tear fluid?
Rantamäki, Antti H; Javanainen, Matti; Vattulainen, Ilpo; Holopainen, Juha M
2012-09-21
We examined in vitro the potential evaporation-retarding effect of the tear film lipid layer (TFLL). The artificial TFLL compositions used here were based on the present knowledge of TFLL composition. A custom-built system was developed to measure evaporation rates at 35°C. Lipids were applied to an air-water interface, and the evaporation rate through the lipid layer was defined as water loss from the interface. A thick layer of olive oil and a monolayer of long-chain alcohol were used as controls. The artificial TFLLs were composed of 1 to 4 lipid species: polar phosphatidylcholine (PC), nonpolar cholesteryl ester, triglycerides, and wax ester (WE). Brewster angle microscopy (BAM) and interfacial shear rheometry (ISR) were used to assess the lateral structure and shear stress response of the lipid layers, respectively. Olive oil and long-chain alcohol decreased evaporation by 54% and 45%, respectively. The PC monolayer and the four-component mixtures did not retard evaporation. WE was the most important evaporation-retardant TFLL lipid (∼20% decrease). In PC/WE mixtures, an ∼90% proportion of WE was required for evaporation retardation. Based on BAM and ISR, WE resulted in more condensed layers than the non-retardant layers. Highly condensed, solid-like lipid layers, such as those containing high proportions of WEs, are evaporation-retardant. In multi-component lipid layers, the evaporation-retardant interactions between carbon chains decrease and, therefore, these lipid layers do not retard evaporation.
Effect of topical cyclopentolate on post-operative pain after pterygium surgery.
Goktas, Sertan; Sakarya, Yasar; Ozcimen, Muammer; Sakarya, Rabia; Alpfidan, Ismail; Ivacık, Ismail Senol; Erdogan, Erkan
2017-11-01
The aim was to evaluate the effectiveness of topical cyclopentolate following pterygium surgery for post-operative ocular pain. All participants had nasal pterygium and underwent pterygium excision and conjunctival autografting with fibrin glue. Participants were randomised into two groups. Participants in group 1 received one per cent cyclopentolate eye drops and artificial tears upon completing surgery and were prescribed self-administered drops three times daily for three days, while participants in group 2 received a control (artificial tears) in a manner identical to group 1. Data were gathered regarding post-operative pain intensity experienced during each of the three days. Pain was graded from zero to 10 according to a visual analogue scale, in which zero signified no pain and 10 signified severe, unbearable pain. This study analysed data regarding 38 participants in group 1 and 40 participants in group 2. Results were defined as median with interquartile range (IQR); median of the pain scores at days one, two and three were as follows, respectively: 4 (IQR 2), 2.5 (IQR 1) and 2 (IQR 1.25) for group 1 and 5 (IQR 1), 3 (IQR 1.75) and 3 (IQR 1) for group 2. Pain scores were significantly lower for group 1 compared with group 2 at days one, two and three (p < 0.05). Topical cyclopentolate seems to be effective and well tolerated following pterygium surgery for post-operative ocular pain. © 2017 Optometry Australia.
Effects of topical diquafosol pretreatment on intraoperative corneal wetting.
Miyake, Goichiro; Ota, Ichiro; Miyake, Kensaku; Zako, Masahiro; Iwaki, Masayoshi
2014-10-01
To examine the effects of pretreatment with diquafosol 3.0% ophthalmic solution on corneal surface wetting during cataract surgery with intraocular lens (IOL) implantation in cases of senile cataract. Shohzankai Medical Foundation, Miyake Eye Hospital, Nagoya, Japan. Prospective randomized single-masked comparative study. Phacoemulsification and IOL implantation were performed in eyes with senile cataract. After a 2-week washout period, patients were randomly assigned to receive 1 drop of diquafosol 3.0% ophthalmic solution or artificial tears 6 times daily for 4 weeks before surgery. The main outcome measure, termed the corneal wetting property, was the time between when a clear image of the operating microscope light source appeared just after the corneal surface was irrigated with a balanced salt solution and the time at which that image began to blur. The study enrolled 51 patients (76 eyes). The mean time to corneal wetting was 50.1 seconds ± 10.8 (SD) in the diquafosol group and 45.3 ± 9.2 seconds in the artificial tears group. The difference between the 2 groups was statistically significant (P<.029). Four-week pretreatment with diquafosol 3.0% ophthalmic solution in patients with senile cataract scheduled for cataract surgery with IOL implantation was effective in enhancing the intraoperative corneal surface wetting property, which suggests improved optical clarity during surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Nieto, Alejandra; Roehl, Holger; Brown, Helen; Adler, Michael; Chalus, Pascal; Mahler, Hanns-Christian
2016-01-01
Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against possible contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow (helium leakage testing). In order to correlate microbial CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificial leaks are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. However, the insertion of copper wires introduces leaks of unknown size and shape. With nonlinear finite element simulations, the aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force. The dependency of the aperture size on the copper wire diameter was quadratic. With the data obtained, we were able to calculate the leak size and model leak shape. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to hole size. Capping force also affected leak size. An increase in the capping force from 30 to 70 N resulted in a reduction of the aperture (leak size) by approximately 50% for all wire diameters. From 30 to 50 N, the reduction was approximately 33%. Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow. In order to correlate microbial ingress CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificially created defects (artificial leaks) are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. Up to date, the insertion of copper wires introduced leaks of unknown size and shape. With nonlinear finite element simulations, the effective aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force, and the leak shape was modelled. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to the hole size. © PDA, Inc. 2016.
42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.
Code of Federal Regulations, 2010 CFR
2010-10-01
... eyeglasses or conventional contact lenses furnished after each cataract surgery during which an intraocular lens is inserted. (3) Leg, arm, back, and neck braces and artificial legs, arms, and eyes, including...
42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.
Code of Federal Regulations, 2011 CFR
2011-10-01
... eyeglasses or conventional contact lenses furnished after each cataract surgery during which an intraocular lens is inserted. (3) Leg, arm, back, and neck braces and artificial legs, arms, and eyes, including...
Riand, N; Boulahia, A; Walch, G
2002-02-01
The painful shoulder is a well-recognized clinical entity in throwers although the pathogenic mechanisms involved are still debated. In 1991 Walch then Jobe developed the concept of posterosuperior impingement to explain lesions observed arthroscopically. This impingement between the deep aspect of the supraspinatus tendon and the glenoid occurs during loaded arm movements. The purpose of this work was to study the different types of lesions observed arthroscopically and to analyse outcome after arthroscopic debridement. Our series included 75 thrower athletes who had shoulder pain for loaded arm movements. Pain was situated in the dominant shoulder in all cases. Clinically, the Jobe manipulation provoked pain in 52 patents, expression of a supraspinous disorder. After failure of conservative treatment, the patients underwent arthroscopy for assessment and debridement. At the time of arthroscopy, the patients had suffered pain for two years (mean 22.3 months). All 75 patients were seen for clinical and radiological assessment at least two years after arthroscopy. Among the 75 arthroscopies, there were 67 (89%) partial tears involving the deep aspect of the cuff, associated in 90% of the cases with a labral lesion. Tears involved the supraspinatus in 40 cases, the supraspinatus and the infraspinatus in 24 and the infraspinatus alone in three. Eight patients were free of tendon lesions at arthroscopy. There were no full thickness tears. The labrum had a meniscal (45%) or non-meniscal aspect (55%) and appeared normal (18%), fringed (38%) or fissured (52%). The very large majority of the labral fissures were found behind the biceps insertion. Fissures of the labrum were found in front of the biceps insertion in only three cases (slap lesion). Arthroscopy demonstrated glenoid damage (soft cartilage, fissure, abrasion, wear). The humeral head also exhibited lesions of the cartilage facing the insertion of the infraspinatus. At last follow-up (minimum > 2 years), eight patients were very satisfied, 22 were satisfied and 45 were disappointed. Twelve patients had resumed their sports activities at their former level with loaded arm movement and one patient had interrupted all sports activities. At last follow-up, 22 patient had undergone another surgical procedure: 20 derotation osteotomies of the humerus, one anterior stabilization, one acromioplasty. The notion of posterosuperior impingement is increasingly recognized as the cause of pain in thrower athletes. Loaded arm movements produce a physiological contact between the posteriorsuperior edge of the glenoid cavity and the deep aspect of the rotator cuff. Injury results from repeated loaded arm movements in throwers. In our series, all the patients had at least one lesion, either involving the cuff or the labrum. According to the Snyder classification, 80% of the supraspinatus lesions were grade 1 or grade 2. We did not have any full thickness tears. All patients with a normal cuff were found to have a lesion of the posterosuperior labrum. At arthroscopy, dynamic assessment evidenced an impingement between the supraspinatus (or the infraspinatus) and the labrum or the bony edge of the glenoid cavity. Only three patients had a labral lesion anterior to the biceps insertion that could be considered a type 1 or 2 slap lesion. Unlike earlier reports by others, we had disappointing results after debridement: 60% of the patients were disappointed after the procedure and only 40% were satisfied (22 patients) or very satisfied (8 patients). Patient satisfaction depended greatly on the level of sports activity attained after arthroscopy, the eight very satisfied patients had resumed their former level. None of the professional athletes or those competing at the international level were very satisfied with arthroscopic debridement. There was an inverse relationship between level of competition and patient satisfaction after debridement.
BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN.
Silva, Patricia; Rosa, Rodrigo César; Shimano, Antonio Carlos; Albuquerque de Paula, Francisco José; Volpon, José Batista; Aparecido Defino, Helton Luiz
2009-01-01
To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were the insertion torque and pullout strength. The following groups were created: Group I-self-tapping screw insertion after pilot hole drilling and tapping; Group II-self-tapping screw insertion after pilot hole drilling without tapping; Group III-self-drilling screw insertion without drilling and tapping. In Groups I and II, the pilot hole had 14.0 mm in depth and was made with a 3mmn drill, while tapping was made with a 4mm tap. The insertion torque was measured and the pullout test was performed. The comparison between groups was made considering the mean insertion torque and the maximum mean pullout strength with the variance analysis (ANOVA; p≤ 0.05). Previous drilling and tapping of pilot hole significantly decreased the insertion torque and the pullout strength. The insertion torque and pullout strength of self-drilling screws were significantly higher when compared to self-tapping screws inserted after pilot hole tapping.
Ultrasound evaluation of a spontaneous plantar fascia rupture.
Louwers, Michael J; Sabb, Brian; Pangilinan, Percival H
2010-11-01
Plantar fascia rupture is an occasional complication in patients with chronic plantar fasciitis or in patients with plantar fasciitis treated with steroid injection. Very few cases of spontaneous plantar fascia rupture have been reported in the literature (Herrick and Herrick, Am J Sports Med 1983;11:95; Lun et al, Clin J Sports Med 1999;9:48-9; Rolf et al, J Foot Ankle Surg 1997;36:112-4; Saxena and Fullem, Am J Sports Med 2004;32:662-5). Spontaneous medial plantar fascia rupture in a 37-yr-old man with no preceding symptoms or steroid injections was confirmed with diagnostic ultrasound, which revealed severe fasciitis at the calcaneal insertion with partial tearing. After conservative treatment, the patient returned to full activities. We discuss the anatomy, risk factors, examination findings, and treatment for this condition, as well as the unique benefits that ultrasound offers over magnetic resonance imaging. It is important to consider plantar fascia rupture in patients with hindfoot pain and medioplantar ecchymosis, particularly if an injury occurred during acceleration maneuvers. Ultrasound in these cases can be used to diagnose a plantar fascia tear quickly, accurately, and cost-effectively.
Arrigoni, Paolo; D'Ambrosi, Riccardo; Randelli, Pietro
2015-12-01
An elongation or partial articular-sided tear of the radial lateral collateral ligament (R-LCL) is a rare injury causing disability and instability of the elbow. In our experience this condition is often associated with a pathologic sign of the annular ligament named the "annular drive through" caused by a redundancy of the ligament. The benefits of performing an arthroscopic procedure for surgical stabilization of the R-LCL include smaller incisions with less soft-tissue dissection, better visualization of the joint, better repair accessibility, and elimination of the annular drive-through sign. The main steps of the operation are as follows: evaluation of annular drive through, inspection of the radial side of the joint, anterior capsulotomy, insertion of a suture anchor through the anterolateral portal, shuttling of the suture anchor through the ligament, and elimination of the annular drive-through sign. By use of this technique, it is possible to repair a lesion of the R-LCL with a suture anchor that ensures an anatomic repair and, at the same time, returns the annular ligament to its physiological tension.
Aquarium Portal Technique for PASTA Lesion Repair.
Meyer, Dominik C; Gerber, Christian; Familiari, Filippo
2017-10-01
The simultaneous arthroscopic exposure of the subacromial and intra-articular space of the shoulder is challenging in the presence of only partial-thickness rotator cuff tears. We present our experience and method of entering the joint through the opened rotator cuff interval from an anterosuperior portal between the coracoid process and anterior acromion. With moderate (approximately 30°) abduction and external rotation, the rotator interval opens readily, offering a view with the camera toward the anterior edge of the supraspinatus tendon. An anterior view on the anterior leading edge of the supraspinatus tendon is obtained, showing the subacromial space above and the glenohumeral space below the tendon, similar to the view in an aquarium. The rotator cuff can be elevated using a rod inserted intra-articularly from posterior, whereas anchors and other instruments may be inserted from lateral. This approach offers the advantages of full exposure of the posterior undersurface of the rotator cuff insertion; a convenient approximately 90° angle between the camera and instruments; and no need to change portals for anchor placement, tendon stitching, or suture handling. The objective of this Technical Note is to describe our arthroscopic repair approach (aquarium technique) to PASTA (partial articular supraspinatus tendon avulsion) lesions.
The imaging features of the meniscal roots on isotropic 3D MRI in young asymptomatic volunteers.
Wang, Ping; Zhang, Cheng-Zhou; Zhang, Di; Liu, Quan-Yuan; Zhong, Xiao-Fei; Yin, Zhi-Jie; Wang, Bin
2018-05-01
This study aimed to describe clearly the normal imaging features of the meniscal roots on the magnetic resonance imaging (MRI) with a 3-dimensional (3D) proton density-weighted (PDW) sequence at 3T. A total of 60 knees of 31 young asymptomatic volunteers were examined using a 3D MRI. The insertion patterns, constitution patterns, and MR signals of the meniscal roots were recorded. The anterior root of the medial meniscus (ARMM), the anterior root of the lateral meniscus (ARLM), and the posterior root of the medial meniscus (PRMM) had 1 insertion site, whereas the posterior root of the lateral meniscus (PRLM) can be divided into major and minor insertion sites. The ARLM and the PRMM usually consisted of multiple fiber bundles (≥3), whereas the ARMM and the PRLM often consisted of a single fiber bundle. The ARMM and the PRLM usually appeared as hypointense, whereas the ARLM and the PRMM typically exhibited mixed signals. The meniscal roots can be complex and diverse, and certain characteristics of them were observed on 3D MRI. Understanding the normal imaging features of the meniscal roots is extremely beneficial for further diagnosis of root tears.
Evolution-based Virtual Content Insertion with Visually Virtual Interactions in Videos
NASA Astrophysics Data System (ADS)
Chang, Chia-Hu; Wu, Ja-Ling
With the development of content-based multimedia analysis, virtual content insertion has been widely used and studied for video enrichment and multimedia advertising. However, how to automatically insert a user-selected virtual content into personal videos in a less-intrusive manner, with an attractive representation, is a challenging problem. In this chapter, we present an evolution-based virtual content insertion system which can insert virtual contents into videos with evolved animations according to predefined behaviors emulating the characteristics of evolutionary biology. The videos are considered not only as carriers of message conveyed by the virtual content but also as the environment in which the lifelike virtual contents live. Thus, the inserted virtual content will be affected by the videos to trigger a series of artificial evolutions and evolve its appearances and behaviors while interacting with video contents. By inserting virtual contents into videos through the system, users can easily create entertaining storylines and turn their personal videos into visually appealing ones. In addition, it would bring a new opportunity to increase the advertising revenue for video assets of the media industry and online video-sharing websites.
Briggs, R J; Tykocinski, M; Saunders, E; Hellier, W; Dahm, M; Pyman, B; Clark, G M
2001-09-01
To review the mechanisms and nature of intracochlear damage associated with cochlear implant electrode array insertion, in particular, the various perimodiolar electrode designs. Make recommendations regarding surgical techniques for the Nucleus Contour electrode to ensure correct position and minimal insertion trauma. The potential advantages of increased modiolar proximity of intracochlear multichannel electrode arrays are a reduction in stimulation thresholds, an increase in dynamic range and more localized neural excitation. This may improve speech perception and reduce power consumption. These advantages may be negated if increased intracochlear damage results from the method used to position the electrodes close to the modiolus. A review of the University of Melbourne Department of Otolaryngology experience with temporal bone safety studies using the Nucleus standard straight electrode array and a variety of perimodiolar electrode array designs; comparison with temporal bone insertion studies from other centres and postmortem histopathology studies reported in the literature. Review of our initial clinical experience using the Nucleus Contour electrode array. The nature of intracochlear damage resulting from electrode insertion trauma ranges from minor, localized, spiral ligament tear to diffuse organ of Corti disruption and osseous spiral lamina fracture. The type of damage depends on the mechanical characteristics of the electrode array, the stiffness, curvature and size of the electrode in relation to the scala, and the surgical technique. The narrow, flexible, straight arrays are the least traumatic. Pre-curved or stiffer arrays are associated with an incidence of basilar membrane perforation. The cochleostomy must be correctly sited in relation to the round window to ensure scala tympani insertion. A cochleostomy anterior to the round window rather than inferior may lead to scala media or scala vestibuli insertion. Proximity of electrodes to the modiolus can be achieved without intracochlear damage provided the electrode array is a free fit within the scala, of appropriate size and shape, and accurate scala tympani insertion is performed.
Anterior Cruciate Ligament Injuries in National Football League Athletes From 2010 to 2013
Dodson, Christopher C.; Secrist, Eric S.; Bhat, Suneel B.; Woods, Daniel P.; Deluca, Peter F.
2016-01-01
Background: There is a high incidence of anterior cruciate ligament (ACL) injuries among National Football League (NFL) athletes; however, the incidence of reinjury in this population is unknown. Purpose: This retrospective epidemiological study analyzed all publicly disclosed ACL tears occurring in NFL players between 2010 and 2013 to characterize injury trends and determine the incidence of reinjury. Study Design: Descriptive epidemiological study. Methods: A comprehensive online search identified any NFL player who had suffered an ACL injury from 2010 to 2013. Position, playing surface, activity, and date were recorded. Each player was researched for any history of previous ACL injury. The NFL games database from USA Today was used to determine the incidence of ACL injuries on artificial turf and grass fields. Databases from Pro Football Focus and Pro Football Reference were used to determine the injury rate for each position. Results: NFL players suffered 219 ACL injuries between 2010 and 2013. Forty players (18.3%) had a history of previous ACL injury, with 27 (12.3%) retears and 16 (7.3%) tears contralateral to a previous ACL injury. Five players (2.28%) suffered their third ACL tear. Receivers (wide receivers and tight ends) and backs (linebackers, fullbacks, and halfbacks) had significantly greater injury risk than the rest of the NFL players, while perimeter linemen (defensive ends and offensive tackles) had significantly lower injury risk than the rest of the players. Interior linemen (offensive guards, centers, and defensive tackles) had significantly greater injury risk compared with perimeter linemen. ACL injury rates per team games played were 0.050 for grass and 0.053 for turf fields (P > .05). Conclusion: In this retrospective epidemiological study of ACL tears in NFL players, retears and ACL tears contralateral to a previously torn ACL constituted a substantial portion (18.3%) of total ACL injuries. The significant majority of ACL injuries in players with a history of previous ACL injury were retears. Skilled offensive players and linebackers had the greatest injury risk, and significantly more ACL tears occurred among interior linemen than perimeter linemen. The month of August had the highest incidence of ACL injuries, probably because of expanded roster sizes at that point in the NFL season. PMID:26998501
Combined heart-kidney transplantation after total artificial heart insertion.
Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F
2015-01-01
We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.
Zhang, Qing-Song; Liu, Sen; Zhang, Qiuyang; Xue, Yun; Ge, Dongxia; O'Brien, Michael J.; Savoie, Felix H.; You, Zongbing
2012-01-01
Objectives. The objective of this study was to compare the damage to the rotator cuff tendons caused by four different anchor systems. Methods. 20 cadaveric human shoulder joints were used for transtendon insertion of four anchor systems. The Healix Peek, Fastin RC, Bio-Corkscrew Suture, and Healix Transtend anchors were inserted through the tendons using standard transtendon procedures. The areas of tendon damage were measured. Results. The areas of tendon damage (mean ± standard deviation, n = 7) were 29.1 ± 4.3 mm2 for the Healix Peek anchor, 20.4 ± 2.3 mm2 for the Fastin RC anchor, 23.4 ± 1.2 mm2 for the Bio-Corkscrew Suture anchor, 13.7 ± 3.2 mm2 for the Healix Transtend anchor inserted directly, and 9.1 ± 2.1 mm2 for the Healix Transtend anchor inserted through the Percannula system (P < 0.001 or P < 0.001, compared to other anchors). Conclusions. In a cadaver transtendon rotator cuff repair model, smaller anchors caused less damage to the tendon tissues. The Healix Transtend implant system caused the least damage to the tendon tissues. Our findings suggest that smaller anchors should be considered when performing transtendon procedures to repair partial rotator cuff tears. PMID:22811923
Wearable physiological systems and technologies for metabolic monitoring.
Gao, Wei; Brooks, George A; Klonoff, David C
2018-03-01
Wearable sensors allow continuous monitoring of metabolites for diabetes, sports medicine, exercise science, and physiology research. These sensors can continuously detect target analytes in skin interstitial fluid (ISF), tears, saliva, and sweat. In this review, we will summarize developments on wearable devices and their potential applications in research, clinical practice, and recreational and sporting activities. Sampling skin ISF can require insertion of a needle into the skin, whereas sweat, tears, and saliva can be sampled by devices worn outside the body. The most widely sampled metabolite from a wearable device is glucose in skin ISF for monitoring diabetes patients. Continuous ISF glucose monitoring allows estimation of the glucose concentration in blood without the pain, inconvenience, and blood waste of fingerstick capillary blood glucose testing. This tool is currently used by diabetes patients to provide information for dosing insulin and determining a diet and exercise plan. Similar technologies for measuring concentrations of other analytes in skin ISF could be used to monitor athletes, emergency responders, warfighters, and others in states of extreme physiological stress. Sweat is a potentially useful substrate for sampling analytes for metabolic monitoring during exercise. Lactate, sodium, potassium, and hydrogen ions can be measured in sweat. Tools for converting the concentrations of these analytes sampled from sweat, tears, and saliva into blood concentrations are being developed. As an understanding of the relationships between the concentrations of analytes in blood and easily sampled body fluid increases, then the benefits of new wearable devices for metabolic monitoring will also increase.
Bacterial Artificial Chromosome Libraries for Mouse Sequencing and Functional Analysis
Osoegawa, Kazutoyo; Tateno, Minako; Woon, Peng Yeong; Frengen, Eirik; Mammoser, Aaron G.; Catanese, Joseph J.; Hayashizaki, Yoshihide; de Jong, Pieter J.
2000-01-01
Bacterial artificial chromosome (BAC) and P1-derived artificial chromosome (PAC) libraries providing a combined 33-fold representation of the murine genome have been constructed using two different restriction enzymes for genomic digestion. A large-insert PAC library was prepared from the 129S6/SvEvTac strain in a bacterial/mammalian shuttle vector to facilitate functional gene studies. For genome mapping and sequencing, we prepared BAC libraries from the 129S6/SvEvTac and the C57BL/6J strains. The average insert sizes for the three libraries range between 130 kb and 200 kb. Based on the numbers of clones and the observed average insert sizes, we estimate each library to have slightly in excess of 10-fold genome representation. The average number of clones found after hybridization screening with 28 probes was in the range of 9–14 clones per marker. To explore the fidelity of the genomic representation in the three libraries, we analyzed three contigs, each established after screening with a single unique marker. New markers were established from the end sequences and screened against all the contig members to determine if any of the BACs and PACs are chimeric or rearranged. Only one chimeric clone and six potential deletions have been observed after extensive analysis of 113 PAC and BAC clones. Seventy-one of the 113 clones were conclusively nonchimeric because both end markers or sequences were mapped to the other confirmed contig members. We could not exclude chimerism for the remaining 41 clones because one or both of the insert termini did not contain unique sequence to design markers. The low rate of chimerism, ∼1%, and the low level of detected rearrangements support the anticipated usefulness of the BAC libraries for genome research. [The sequence data described in this paper have been submitted to the GenBank data library under accession numbers AQ797173–AQ797398.] PMID:10645956
Validation of artificial skin equivalents as in vitro testing systems
NASA Astrophysics Data System (ADS)
Schmitt, Robert; Marx, Ulrich; Walles, Heike; Schober, Lena
2011-03-01
With the increasing complexity of the chemical composition of pharmaceuticals, cosmetics and everyday substances, the awareness of potential health issues and long term damages for humanoid organs is shifting into focus. Artificial in vitro testing systems play an important role in providing reliable test conditions and replacing precarious animal testing. Especially artificial skin equivalents ASEs are used for a broad spectrum of studies like penetration, irritation and corrosion of substances. One major challenge in tissue engineering is the qualification of each individual ASE as in vitro testing system. Due to biological fluctuations, the stratum corneum hornified layer of some ASEs may not fully develop or other defects might occur. For monitoring these effects we developed an fully automated Optical Coherence Tomography device. Here, we present different methods to characterize and evaluate the quality of the ASEs based on image and data processing of OCT B-scans. By analysing the surface structure, defects, like cuts or tears, are detectable. A further indicator for the quality of the ASE is the morphology of the tissue. This allows to determine if the skin model has reached the final growth state. We found, that OCT is a well suited technology for automatically characterizing artificial skin equivalents and validating the application as testing system.
Ketorolac inhibits choroidal neovascularization by suppression of retinal VEGF
Kim, Stephen J.; Toma, Hassanain S.; Barnett, Joshua M.; Penn, John S.
2011-01-01
We assessed the effect of topical ketorolac on laser-induced choroidal neovascularization (CNV), measured retinal PGE2 and VEGF levels after laser treatment, and determined the effect of ketorolac on PGE2 and VEGF production. Six laser burns were placed in eyes of rats which then received topical ketorolac 0.4% or artificial tears four times daily until sacrifice. Fluorescein angiography (FA) was performed at 2 and 3 weeks and retinal pigment epithelium-choroid-sclera flat mounts were prepared. The retina and vitreous were isolated at 1, 3, 5, 7, and 14 days after laser treatment and tested for VEGF and PGE2. Additional animals were lasered and treated with topical ketorolac or artificial tears and tested at 3 and 7 days for retinal and vitreous VEGF and PGE2. Ketorolac reduced CNV on FA by 27% at 2 weeks (P < 0.001) and 25% at 3 weeks (P < 0.001). Baseline retina and vitreous PGE2 levels were 29.4 μg/g and 16.5 μg/g respectively, and reached 51.2 μg/g and 26.9 μg/g respectively, 24 h after laser treatment (P < 0.05). Retinal VEGF level was 781 pg/g 24 h after laser treatment and reached 931 pg/g by 7 days (P < 0.01). Ketorolac reduced retinal PGE2 by 35% at 3 days (P < 0.05) and 29% at 7 days (P < 0.001) and retinal VEGF by 31% at 3 days (P = 0.10) and 19% at 7 days (P < 0.001). Topical ketorolac inhibited CNV and suppressed retinal PGE2 and VEGF production. PMID:20659449
Livingston, Michael H.; Pepe, Daniel; Jones, Sarah; Bütter, Andreana; Merritt, Neil H.
2015-01-01
Background This study describes our experience with the placement of a skin-level gastrostomy device (MIC-KEY) in a single procedure. Methods We identified infants, children and young adults who underwent laparoscopic-assisted percutaneous endoscopic gastrostomy (LAPEG) tube insertion between October 2009 and June 2013. The steps of this procedure include upper endoscopy, single-port laparoscopy, gastropexy via percutaneous T-fasteners and placement of a skin-level gastrostomy device (MIC-KEY) using a “push” technique with a tear-away sheath. Results We included 92 patients in our study. Mean age was 3.7 years (range 3 wk–5 yr), and mean weight was 11.2 (range 2.8–54) kg. Median procedural time was 20 (range 12–76) minutes. Total median duration for the most recent 25 procedures was lower than that of the first 25 (62 v. 79 min, p = 0.004). There were no intraoperative complications or conversions to open surgery. Postoperative complications were observed in 6 (6.5%) patients. Three retained T-fasteners were assessed endoscopically (n = 1) or removed via local excision (n = 2). Two patients experienced early dislodged feeding tubes that were replaced via interventional radiology (n = 1) or repeat LAPEG (n = 1). There was also 1 intra-abdominal fluid collection that was drained percutaneously but ultimately required a laparotomy and washout. There were no major complications in the most recent 50 procedures. Conclusion Our results suggest that LAPEG is a safe, minimally invasive procedure for infants, children and young adults. This approach allows for immediate use of a skin-level gastrostomy device without the need for postoperative tube exchanges. PMID:26204365
Going, going, gone: predicting the fate of genomic insertions in plant RNA viruses.
Willemsen, Anouk; Carrasco, José L; Elena, Santiago F; Zwart, Mark P
2018-05-10
Horizontal gene transfer is common among viruses, while they also have highly compact genomes and tend to lose artificial genomic insertions rapidly. Understanding the stability of genomic insertions in viral genomes is therefore relevant for explaining and predicting their evolutionary patterns. Here, we revisit a large body of experimental research on a plant RNA virus, tobacco etch potyvirus (TEV), to identify the patterns underlying the stability of a range of homologous and heterologous insertions in the viral genome. We obtained a wide range of estimates for the recombination rate-the rate at which deletions removing the insertion occur-and these appeared to be independent of the type of insertion and its location. Of the factors we considered, recombination rate was the best predictor of insertion stability, although we could not identify the specific sequence characteristics that would help predict insertion instability. We also considered experimentally the possibility that functional insertions lead to higher mutational robustness through increased redundancy. However, our observations suggest that both functional and non-functional increases in genome size decreased the mutational robustness. Our results therefore demonstrate the importance of recombination rates for predicting the long-term stability and evolution of viral RNA genomes and suggest that there are unexpected drawbacks to increases in genome size for mutational robustness.
Chung, Michael; Radacsi, Norbert; Robert, Colin; McCarthy, Edward D; Callanan, Anthony; Conlisk, Noel; Hoskins, Peter R; Koutsos, Vasileios
2018-01-01
There is a potential for direct model manufacturing of abdominal aortic aneurysm (AAA) using 3D printing technique for generating flexible semi-transparent prototypes. A patient-specific AAA model was manufactured using fused deposition modelling (FDM) 3D printing technology. A flexible, semi-transparent thermoplastic polyurethane (TPU), called Cheetah Water (produced by Ninjatek, USA), was used as the flexible, transparent material for model manufacture with a hydrophilic support structure 3D printed with polyvinyl alcohol (PVA). Printing parameters were investigated to evaluate their effect on 3D-printing precision and transparency of the final model. ISO standard tear resistance tests were carried out on Ninjatek Cheetah specimens for a comparison of tear strength with silicone rubbers. It was found that an increase in printing speed decreased printing accuracy, whilst using an infill percentage of 100% and printing nozzle temperature of 255 °C produced the most transparent results. The model had fair transparency, allowing external inspection of model inserts such as stent grafts, and good flexibility with an overall discrepancy between CAD and physical model average wall thicknesses of 0.05 mm (2.5% thicker than the CAD model). The tear resistance test found Ninjatek Cheetah TPU to have an average tear resistance of 83 kN/m, higher than any of the silicone rubbers used in previous AAA model manufacture. The model had lower cost (4.50 GBP per model), shorter manufacturing time (25 h 3 min) and an acceptable level of accuracy (2.61% error) compared to other methods. It was concluded that the model would be of use in endovascular aneurysm repair planning and education, particularly for practicing placement of hooked or barbed stents, due to the model's balance of flexibility, transparency, robustness and cost-effectiveness.
Hossien, Abdullrazak; Gelsomino, Sandro; Mochtar, Baheramsjah; Maessen, Jos G; Sardari Nia, Peyman
2015-11-01
Acute type A aortic dissection (TAAD) is a life-threatening emergency and requires immediate surgical intervention. We propose a novel finite element multi-dimensional modelling (FE-MDM) technique to identify aortic tears preoperatively to aid surgical preplanning. Thirty-two patients with TAAD were included in this retrospective study. Computed tomography (CT) scans were imported using the segmentation software and reconstruction resulted in modelling of single TAAD components: aortic wall, false lumen, true lumen, gap in the flap and blood in both lumens. CT scans were processed by interpreters who were blinded to the clinical data and then were compared with operative findings. The models were assessed and compared regarding localization and size of the entry tear with the intraoperative findings. Image set data were retrieved from CT scans. Surgical inspection confirmed the localization of the tear obtained by the model in all patients with a 100% chance prediction (P < 0.0001) in all patients. With the simulation of the guided-cannulation, it was possible to place the cannula in the ascending aorta in 100% of patients (P < 0.0001 vs surgery). Using the virtual volume model, the chance of inserting into the false lumen was 0% (P < 0.0001). There was a strong correlation between the virtual volume model and cannulation in the true lumen (r = 0.88, P < 0.0001). The FE-MDM technique of aortic dissection is helpful in identifying the site of the tear and may be considered as an additional tool in surgical preplanning. It may also enhance the efficiency of deep hypothermic circulatory arrest in patients with single entry sites in the ascending aorta and it may facilitate direct cannulation of the ascending aorta. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Zhang, Chun-Gang; Zhao, De-Wei; Wang, Wei-Ming; Ren, Ming-Fa; Li, Rui-Xin; Yang, Sheng; Liu, Yu-Peng
2010-11-01
For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of ≤ 45° into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Gap formation for the transtendon single-row repair was significantly smaller (P < 0.05) when compared with the double-row repair for the first cycle ((1.74 ± 0.38) mm vs. (2.86 ± 0.46) mm, respectively) and the last cycle ((3.77 ± 0.45) mm vs. (5.89 ± 0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P < 0.05) when compared with the double-row repair. Also, it had a higher mean ultimate tensile load and stiffness. For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation.
Ahyai, Sascha A; Ludwig, Tim A; Dahlem, Roland; Soave, Armin; Rosenbaum, Clemens; Chun, Felix K-H; Fisch, Margit; Schmid, Marianne; Kluth, Luis A
2016-10-01
To evaluate continence and complication rates of bulbar single-cuff (SC) and distal bulbar double-cuff (DC) insertion in male patients with severe stress urinary incontinence (SUI) according to whether the men were considered low or high risk for unfavourable artificial urinary sphincter (AUS) outcomes. In all, 180 male patients who underwent AUS implantation between 2009 and 2013 were followed according to institutional standards. Patients with previous pelvic radiation therapy, open bulbar urethral or UI surgery ('high risk') underwent distal bulbar DC (123 patients) insertion, all others ('low risk') had proximal bulbar SC (57) insertion. Primary and secondary endpoints consisted of continence and complication rates. Kaplan-Meier analysis determined explantation-free survival, and Cox regression models assessed risk factors for persistent UI and explantation. The median follow-up was 24 months. Whereas there was no significant difference in pad usage/objective continence after SC vs DC insertion, superior rates of subjective/social continence and less persistent UI were reported by the patients with DC devices (all P ≤ 0.02). Overall, device explantation (erosion, infection or mechanical failure) occurred in 12.8% of patients. While early (<6 weeks) complication rates compared with SC patients were similar (P > 0.05), DC patients had a 5.7-fold higher risk of device explantation during late follow-up (P = 0.02) and significantly shorter explantation-free survival (log-rank, P = 0.003). Distal bulbar DC insertion in patients with a 'high-risk' profile (previous pelvic radiation, urethral surgery) leads to similar objective continence, but higher explantation rates when compared with patients considered 'low risk' with proximal bulbar SCs. Randomised controlled trials comparing both devices will be needed to determine whether the higher explanations rates are attributable to the DC device or to underlying risk factors. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
Mechanisms and management of dry eye in cataract surgery patients.
Sutu, Christine; Fukuoka, Hideki; Afshari, Natalie A
2016-01-01
To provide a summary of the mechanisms that may cause dry eye after cataract surgery and discuss available and upcoming treatment modalities. Development or worsening of dry eye symptoms after cataract surgery is multifactorial with corneal nerve transection, inflammation, goblet cell loss, and meibomian gland dysfunction commonly cited as underlying disorders. With increasing awareness of the prevalence of dry eye disease, current surgical techniques are being analyzed for their contribution to the issue. Although many classic interventions, such as artificial tears and anti-inflammatory drops, remain first-line treatment options, they may not adequately address abnormalities of the tear film. The trend has been to create new drugs and technologies that target meibomian gland deficiencies and restore goblet cell numbers. Therapy for postoperative dry eye symptoms should be determined based on symptom severity and which underlying cause is most prominent at a given time. Patients with high-level risk factors for dry eye should be evaluated preoperatively to determine whether they have preexisting dry eye disease or if they are susceptible to developing disease after surgery.
NASA Astrophysics Data System (ADS)
Craig, D.; Martin, D.; Den Hartog, D. J.; Nornberg, M. D.; Reusch, J. A.
2017-08-01
We investigate the role of poloidal mode number m = 0 fluctuations on m = 1 velocity and magnetic field fluctuations in the Reversed Field Pinch (RFP). Removing the m = 0 resonant surface in the Madison Symmetric Torus (MST), results in suppressed m = 0 activity without a reduction in m = 1 magnetic activity. However, the m = 1 velocity fluctuations and fluctuation-induced mean emf are reduced as m = 0 modes are suppressed. Velocity fluctuations are measured directly using fast Doppler spectroscopy. Similar results are seen in visco-resistive MHD simulation with the DEBS code. An artificial line-averaged velocity diagnostic is developed for DEBS simulations to facilitate direct comparisons with experimental measurements. The sensitivity of the m = 1 velocity fluctuations and corresponding emf to changes in m = 0 mode activity is a feature of tearing modes in the nonlinear regime with a spectrum of interacting modes. These results have implications for RFP sustainment strategies and inform our understanding of the role of magnetic turbulence in astrophysical contexts.
Surfactant properties of human meibomian lipids.
Mudgil, Poonam; Millar, Thomas J
2011-03-25
Human meibomian lipids are the major part of the lipid layer of the tear film. Their surfactant properties enable their spread across the aqueous layer and help maintain a stable tear film. The purpose of this study was to investigate surfactant properties of human meibomian lipids in vitro and to determine effects of different physical conditions such as temperature and increased osmolarity, such as occur in dry eye, on these properties. Human meibomian lipids were spread on an artificial tear solution in a Langmuir trough. The lipid films were compressed and expanded to record the surface pressure-area (Π-A) isocycles. The isocycles were recorded under different physical conditions such as high pressure, increasing concentration and size of divalent cations, increasing osmolarity, and varying temperature. Π-A isocycles of meibomian lipids showed that they form liquid films that are compressible and multilayered. The isocycles were unaffected by increasing concentration or size of divalent cations and increasing osmolarity in the subphase. Temperature had a marked effect on the lipids. Increase in temperature caused lipid films to become fluid, an expected feature, but decrease in temperature unexpectedly caused expansion of lipids and an increase in pressure suggesting enhanced surfactant properties. Human meibomian lipids form highly compressible, non-collapsible, multilayered liquid films. These lipids have surfactants that allow them to spread across an aqueous subphase. Their surfactant properties are unaffected by increasing divalent cations or hyperosmolarity but are sensitive to temperature. Cooling of meibomian lipids enhances their surfactant properties.
FLUID MECHANICS OF ARTIFICIAL HEART VALVES
Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P
2009-01-01
SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329
Fluid mechanics of artificial heart valves.
Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P
2009-02-01
1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.
Virtual Reality for Artificial Intelligence: human-centered simulation for social science.
Cipresso, Pietro; Riva, Giuseppe
2015-01-01
There is a long last tradition in Artificial Intelligence as use of Robots endowing human peculiarities, from a cognitive and emotional point of view, and not only in shape. Today Artificial Intelligence is more oriented to several form of collective intelligence, also building robot simulators (hardware or software) to deeply understand collective behaviors in human beings and society as a whole. Modeling has also been crucial in the social sciences, to understand how complex systems can arise from simple rules. However, while engineers' simulations can be performed in the physical world using robots, for social scientist this is impossible. For decades, researchers tried to improve simulations by endowing artificial agents with simple and complex rules that emulated human behavior also by using artificial intelligence (AI). To include human beings and their real intelligence within artificial societies is now the big challenge. We present an hybrid (human-artificial) platform where experiments can be performed by simulated artificial worlds in the following manner: 1) agents' behaviors are regulated by the behaviors shown in Virtual Reality involving real human beings exposed to specific situations to simulate, and 2) technology transfers these rules into the artificial world. These form a closed-loop of real behaviors inserted into artificial agents, which can be used to study real society.
[Evaluation of the cosmetic effect of orbital endoimplantation after removal the eyeball].
Piskiniene, Raimonda
2006-01-01
The purpose of our study was to evaluate the cosmetic effect of endoimplantation after removal the eyeball. The removal of the globe creates anatomic and physiological alteration of the orbital tissue and orbital bones. A volume deficit occurs when an eye is enucleated. Deep upper lid sulcus, ptosis, lower lid laxity, and enophthalmus of the artificial eye together constitute the postenucleation socket syndrome, which creates an asymmetry of the face. The orbital prosthesis by placing it in the orbital cavity allows correcting volume deficit, so the implant with attached extraocular muscles, together with an artificial eye, creates an illusion of real eye. Forty patients were operated on in Clinic of Eye Diseases of Kaunas University of Medicine Hospital. Twenty patients underwent removal of the eye and procedure of orbital implant insertion (main group). Twenty patients had just an eyeball removal without insertion of an orbital implant (control group). There was a statistically significant difference in exophthalmometry data between main and control groups (14.20+/-2.73 vs. 10.35+/-1.23 mm, respectively; p<0.05). The motility of artificial eye laterally (4.30+/-1.66 mm), medially (3.65+/-1.23 mm), up (3.70+/-1.13 mm), and down (3.40+/-1.19 mm) in the main group was significantly better as compared to the control group (p<0.05), where motility of the artificial eye was 0.60+/-0.68 mm laterally, 0.70+/-0.92 mm medially, 0.30+/-0.66 mm up, and 0.30+/-0.47 mm down. Therefore, a much better symmetry, better movement of the artificial eye, and less severe form of postenucleation syndrome were observed in patients who underwent orbital endoimplantation after eyeball removal.
Arthroscopic-Assisted Triangular Fibrocartilage Complex Reconstruction.
Chu-Kay Mak, Michael; Ho, Pak-Cheong
2017-11-01
Injury of the triangular fibrocartilage complex (TFCC) is a common cause of ulnar-sided wrist pain. Volar and dorsal radioulnar ligaments and their foveal insertion are the most important stabilizing components of the TFCC. In irreparable tears, anatomic reconstruction of the TFCC aims to restore normal biomechanics and stability of the distal radioulnar joint. We proposed a novel arthroscopic-assisted technique using a palmaris longus tendon graft. Arthroscopic-assisted TFCC reconstruction is a safe and effective approach with outcomes comparable to conventional open reconstruction and may result in a better range of motion from minimizing soft tissue dissection and subsequent scarring. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Dahl, Roy W.; Keating, Karen; Salamone, Daryl J.; Levy, Laurence; Nag, Barindra; Sanborn, Joan A.
1987-01-01
This paper presents an algorithm (WHAMII) designed to solve the Artificial Intelligence Design Challenge at the 1987 AIAA Guidance, Navigation and Control Conference. The problem under consideration is a stochastic generalization of the traveling salesman problem in which travel costs can incur a penalty with a given probability. The variability in travel costs leads to a probability constraint with respect to violating the budget allocation. Given the small size of the problem (eleven cities), an approach is considered that combines partial tour enumeration with a heuristic city insertion procedure. For computational efficiency during both the enumeration and insertion procedures, precalculated binomial probabilities are used to determine an upper bound on the actual probability of violating the budget constraint for each tour. The actual probability is calculated for the final best tour, and additional insertions are attempted until the actual probability exceeds the bound.
Nakamichi, Masayuki
2004-01-30
The present study examined the use and making of tools to obtain foodstuffs in artificial-mound holes by five captive, group-living Sumatran orangutans (Pongo pygmaeus abelii). Three adult orangutans frequently stripped leaves and twigs from a branch provided (tool-making), and then inserted the tool into a hole to obtain foodstuffs (tool-using). A 5-year-old female juvenile usually used the tools that adult orangutans had previously used, but rarely made tools herself. A 2-year-old male infant did not use any tools. The adult orangutans tend to leave one to several leaves at the top of the branch than to leave many leaves on the branch or to strip all leaves. It seemed likely that tools with appropriate leaves are easier to insert into holes and obtain more foodstuffs, compared with branches with many leaves or sticks without any leaves. When the orangutans were unable to insert a tool into a hole, they usually modified the tool and/or changed their tool-using technique, such as changing how they grasped the tool. These findings are discussed from the perspectives of the orangutan's behavioral flexibility regarding tool-use skills and hierarchical organization in food-processing techniques.
Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.
Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf
2009-12-01
The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.
A New Technique for Preserving the Form of Artificially Inflated Endophalli of Bees.
Dutra, A L; Oliveira, R
2017-04-01
We present a simple technique for keeping the form of artificially expanded endophalli in bees (Hymenoptera). Endophalli were inflated using the introduction of low melting-point agarose from a syringe inserted in the anterior opening of the metasoma. Under refrigeration, the endophalli kept their expanded shape for up to three days allowing the description of structure, morphometric analyses, and examination of the external sculpturing of the cuticle under scanning electron microscope. The technique provides new possibilities for the study of functional morphology, sexual selection, and reconstruction of bee phylogeny.
McDonnell, Peter J; Pflugfelder, Stephen C; Stern, Michael E; Hardten, David R; Conway, Taryn; Villanueva, Linda; Hollander, David A
2017-12-28
The aim of this research is to initiate a 5-year natural history study of dry eye disease (DED) using objectively assessed and patient-reported outcomes, to explore the hypothesis that DED is a progressive condition that has substantive and measurable impacts not only on the ocular surface, but on quality of life and visual functioning. Our objective for this report is to examine the baseline data. A multicenter, prospective, controlled, observational study of Level 2 (mild-to-moderate) DED patients based on International Task Force Delphi Panel severity grading, and controls, documented baseline measures (including tear film biomarkers and quality of life). Tear cytokine concentrations were also measured in the tear film. Patients were using artificial tears as needed. Two hundred seventeen DED patients and 67 gender- and age-matched controls were enrolled. A majority were females and Caucasian and groups did not differ significantly in terms of gender, race, or age. Differences between DED and matched controls, at baseline, included mean scores for Ocular Surface Disease Index (31.7 vs 4.1, P < 0.0001), Schirmer test (5.7 vs 15.3 mm, P < 0.0001), corneal staining (1.4 vs 0.2, P < 0.0001), conjunctival staining (1.4 vs 0.3, P < 0.0001), and tear break-up time (5.7 vs 8.5 s, P < 0.0001). Tear cytokines levels were determined and included interferon-γ, interleukin (IL)-1β, IL-2, IL-4, IL-6, IL-8, tumor necrosis factor-α, epidermal growth factor, IL-13, IL-17, IL-1α, and inducible protein-10. The mean levels of IL-8 and IL-6 were slightly higher in the DED group at baseline. Blurred vision was reported as moderate/severe/very severe at baseline in 57.6% of DED patients vs.10.5% of normal controls (P < 0.0001). DED patients reported greater reductions in work and non-work productivity, as well as greater need for visits to ophthalmologists during the prior year. In this report of the baseline findings of a 5-year natural history study of DED, a striking disease burden is observed with regard to blurred vision, productivity, and visits to eye care practitioners in mild to moderate DED patients compared to normal subjects of similar ages and genders. ClinicalTrials.gov NCT00833235 on January 30, 2009.
Salivation induced better lacrimal gland function in dry eyes.
Pramanik, T; Ghising, R
2009-12-01
The dry eye syndrome is a common eye symptom causing blurry vision. To meet the demand of the modem world students and professionals are compelled to expose themselves to the computer screen for long stretch of time, which is one of the causes of dry eye. It is not always feasible to instil eyes with artificial tears time to time to protect them from dryness. Rather to adopt any simple physiological process associated with optimum lacrimation is a better option to keep eyes moist during computer works. Volunteers (n = 22) having mild dry eyes participated in this study. Tear production was assessed by Schirmer test by keeping Schirmer strip on ocular surface for 5 minutes and recording the length of the moistened area. Then the subject was allowed to keep a piece of lopsy candy (a sour fruit pulp mixed with sugar that is sweet and sour in taste) in mouth for 5 minutes that caused salivation. During salivation, again tear production was assessed. [It was standardized in such a way that, the length of the moistened strip will be 25 - 30 mm for normal eyes, 15 - 10 mm for dry eye, 06 - 10 mm for mild dry eye, 02 - 05 mm for moderate dryness and 00 - 01 mm for severe dry eye.] Tear production was found to be increased significantly (supported by increased length of moistened area of Schirmer strip) during salivation especially in dry eye in all volunteers. The lacrimal gland is the major contributor to the aqueous layer of the tear film which consists of water, electrolytes and proteins; secretion of which are under tight neural control. Anticholinergic agents play an important role in ocular dryness because of hypo-secretion. The sensory root of facial nucleus contains efferent preganglionic parasympathetic fibers for submandibular and sublingual salivary gland and lacrimal gland. The sensory root conveys gustatory fibers from the presulcul area (anterior two-third) of the tongue via the chorda tympani and via the palatine and greater petrosal nerve, taste fibers from the soft palate; it also carries preganglionic (secretomotor) innervations of the submandibular and sublingual salivary gland, lacrimal gland and gland of nasal and palatine mucosa. The taste sensation from the anterior two-third of the tongue, carried by the seventh cranial nerve, a nerve, parasympathetic in nature that contains efferent preganglionic fibers to lacrimal gland. Being stimulated, seventh cranial nerve helps in secretion of tear from the lacrimal glands and gives a sense of relief to the persons facing the problem of mild dryness of eyes.
Derivation of an artificial gene to improve classification accuracy upon gene selection.
Seo, Minseok; Oh, Sejong
2012-02-01
Classification analysis has been developed continuously since 1936. This research field has advanced as a result of development of classifiers such as KNN, ANN, and SVM, as well as through data preprocessing areas. Feature (gene) selection is required for very high dimensional data such as microarray before classification work. The goal of feature selection is to choose a subset of informative features that reduces processing time and provides higher classification accuracy. In this study, we devised a method of artificial gene making (AGM) for microarray data to improve classification accuracy. Our artificial gene was derived from a whole microarray dataset, and combined with a result of gene selection for classification analysis. We experimentally confirmed a clear improvement of classification accuracy after inserting artificial gene. Our artificial gene worked well for popular feature (gene) selection algorithms and classifiers. The proposed approach can be applied to any type of high dimensional dataset. Copyright © 2011 Elsevier Ltd. All rights reserved.
Yeh, Po-Ting; Chien, Hsu-Chih; Ng, Kwong; Tseng, Sung-Huei; Chen, Wei-Li; Hou, Yu-Chih; Wang, I-Jong; Chu, Hsiao-Sung; Kao Yang, Yea-Huei; Hu, Fung-Rong
2015-05-01
Accurate diagnosis and early recognition of dry eye symptoms are important in the management of dry eye disease (DED). This study aimed to evaluate concordance between patient and clinician assessment of DED severity and treatment response. This cross-sectional study was conducted in 2 ophthalmology clinics in Taiwan. Clinicians assessed severity based on the Dry Eye Workshop severity grading (levels 1-4; where 4 = most severe), whereas patients completed the Ocular Surface Disease Index questionnaire. To evaluate the treatment response, patients completed the Subject Global Assessment scale, and clinicians independently assessed patients using the Clinical Global Impression scale. A total of 466 patients were included. Clinicians graded 88.3% of patients as level 1/2, 9.0% as level 3, and 2.7% as level 4 Dry Eye Workshop severity, whereas 44.9% of patients reported normal/mild symptoms, 17.1% with moderate severity, and 38.0% with severe DED. Patients were primarily treated with artificial tears. The clinician assessed 10.3% of patients as unchanged on disease severity after treatment and 88.0% as improved, whereas 49.2% of patients reported dry eye symptoms being almost the same after treatment and 34.6% reported improved symptoms. There was low agreement between clinician and patient assessments in terms of disease severity (rho = 0.17, P < 0.001) and treatment response (rho = 0.22, P < 0.001). There were marked differences in the degree of DED severity and treatment response between patient and clinician assessment. Clinicians may underestimate DED severity and persistence of dry eye symptoms after treatment with artificial tears.Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01942226.
Direct Laser Writing of Nanophotonic Structures on Contact Lenses.
AlQattan, Bader; Yetisen, Ali K; Butt, Haider
2018-04-24
Contact lenses are ubiquitous biomedical devices used for vision correction and cosmetic purposes. Their application as quantitative analytical devices is highly promising for point-of-care diagnostics. However, it is a challenge to integrate nanoscale features into commercial contact lenses for application in low-cost biosensors. A neodymium-doped yttrium aluminum garnet (Nd:YAG) laser (1064 nm, 3 ns pulse, 240 mJ) in holographic interference patterning mode was utilized to produce optical nanostructures over the surface of a hydrogel contact lens. One-dimensional (925 nm) and two-dimensional (925 nm × 925 nm) nanostructures were produced on contact lenses and analyzed by spectroscopy and angle-resolve measurements. The holographic properties of these nanostructures were tested in ambient moisture, fully hydrated, and artificial tear conditions. The measurements showed a rapid tuning of optical diffraction from these nanostructures from 41 to 48°. The nanostructures were patterned near the edges of the contact lens to avoid any interference and obstruction to the human vision. The formation of 2D nanostructures on lenses increased the diffraction efficiency by more than 10%. The versatility of the holographic laser ablation method was demonstrated by producing four different 2D nanopattern geometries on contact lenses. Hydrophobicity of the contact lens was characterized by contact angle measurements, which increased from 59.0° at pristine condition to 62.5° at post-nanofabrication. The holographic nanostructures on the contact lens were used to sense the concentration of Na + ions. Artificial tear solution was used to simulate the conditions in dry eye syndrome, and nanostructures on the contact lenses were used to detect the electrolyte concentration changes (±47 mmol L -1 ). Nanopatterns on a contact lens may be used to sense other ocular diseases in early stages at point-of-care settings.
Arikan, Sedat; Gokmen, Ferhat; Comez, Arzu Taskiran; Gencer, Baran; Kara, Selcuk; Akbal, Ayla
2015-01-01
The contrast sensitivity (CS) function in patients with primary Sjögren's syndrome (pSS) may be impaired either frequently as a result of dry eye diseases or rarely as a result of optic neuropathy. In this study, we aimed to evaluate the CS function in pSS patients as well as to assess corneal aberrations and thickness of the peripapillary retinal nerve fiber layer (pRNFL). Fourteen eyes of 14 pSS patients (pSS group) and 14 eyes of 14 healthy participants (control group) were subjected to assessment of CS at the spatial frequencies of 1.5, 3.0, 6.0, 12, and 18 cycles/degree (cpd) using a functional visual acuity contrast test (FACT); measurement of corneal high-order aberrations (HOAs) in terms of coma-like, spherical-like, and total HOAs using Scheimpflug corneal topography; and measurement of the thickness of both the macular ganglion cell-inner plexiform layer (mGCIPL) and pRNFL in all quadrants using optical coherence tomography. None of the participants were under treatment with artificial tears. The results of the CS test did not differ between the 2 groups at all spatial frequencies (p>0.05). In addition, there were no statistically significant differences between the 2 groups in terms of corneal HOAs (p>0.05) and thickness of mGCIPL (p>0.05). However, among all quadrants, only the inferior quadrant of pRNFL in pSS patients was statistically significantly thinner than that in the healthy participants (p=0.04). The CS function in pSS patients can be maintained with normal thickness of both pRNFL and mGCIPL and with lack of increased corneal HOAs, which may be present even in the absence of artificial tear usage.
Nguyen, Caroline Tram; Chambers, Mark S; Powers, John M; Kiat-Amnuay, Sudarat
2013-06-01
There are reports of dissatisfaction with color instability and reduced lifetime of extraoral maxillofacial prostheses. Previous studies showed that UV mineral-based light-protecting agent (LP) improved color stability of MDX4-4210/Type A silicone elastomer. However, effects of this agent and opacifiers on mechanical properties of the elastomer are unknown. The purpose of this study was to evaluate the effect of 2 commonly used opacifiers and LP, a new opacifier, when combined with pigments on the mechanical properties of MDX4-4210/Type A silicone elastomer before and after artificial aging. Two commonly used opacifiers, titanium white dry pigment (TW) and silicone intrinsic white (SW) and LP were each combined with MDX4-4210/type A. Artists' oil pigment was then combined with the LP and TW groups, and silicone intrinsic pigments were combined with the SW group with 5 colors (no pigment=control, red, yellow, blue, or a combination of the 3 pigments). Ten dumbbell-shaped and 10 trouser-shaped specimens of each opacifier + pigment mixture, plus a control group with no opacifier and no pigment, were made for a total of 320 specimens. Half of the specimens (n=5) were aged in a chamber at 450 kJ/m(2). Specimens were tested for hardness (ASTM D2240), tensile strength (ASTM D412), tear strength (ASTM D624), and percentage elongation in a universal testing machine. A 3-way ANOVA and the Fisher PLSD test were performed (α=.05) for each mechanical property. After accelerated aging, values of Shore A hardness were the lowest for LP with all 5 pigments and the control, followed by SW and TW (P<.001). After accelerated aging, tear strength, tensile strength, and elongation decreased significantly (P<.001) for LP, whereas changes for SW and TW varied depending on the pigment. The mechanical properties of specimens with the light-protecting opacifier were adversely affected after being subjected to artificial aging. SW and TW preserved the mechanical properties of silicone in this study. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Renard, Eric
2008-07-01
Insulin delivery is a crucial component of a closed-loop system aiming at the development of an artificial pancreas. The intravenous route, which has been used in the bedside artificial pancreas model for 30 years, has clear advantages in terms of pharmacokinetics and pharmacodynamics, but cannot be used in any ambulatory system so far. Subcutaneous (SC) insulin infusion benefits from the broad expansion of insulin pump therapy that promoted the availability of constantly improving technology and fast-acting insulin analog use. However, persistent delays of insulin absorption and action, variability and shortterm stability of insulin infusion from SC-inserted catheters generate effectiveness and safety issues in view of an ambulatory, automated, glucose-controlled, artificial beta cell. Intraperitoneal insulin delivery, although still marginally used in diabetes care, may offer an interesting alternative because of its more-physiological plasma insulin profiles and sustained stability and reliability of insulin delivery.
Increased Content Knowledge of Students with Visual Impairments as a Result of Extended Descriptions
ERIC Educational Resources Information Center
Ely, Richard; Emerson, Robert Wall; Maggiore, Theresa; Rothberg, Madeleine; O'Connell, Trisha; Hudson, Laurel
2006-01-01
The National Center for Accessible Media has developed a technology and protocol for inserting extended, enhanced descriptions of visually based concepts into artificially paused digital video. These "eDescriptions" describe material not fully explained by a narrator and provide analogies and explanation specifically designed for…
Gause, A
2007-02-01
For the treatment of sicca symptoms as a manifestation of Sjögren's syndrome there are various tear substitutes as well as artificial saliva. The appropriate substances are discussed in this article. In addition to reducing symptoms, some of the effective compounds offer the advantage of infection prophylaxis in the form of better lubrication of the mucous membranes in the airways as well as reduced susceptibility to candidiasis. The presence of bromhexin in the catalogue of the statutory medical insurance agencies is recommended. Certain of the available drugs are still only available in foreign pharmacies.
Vidil, A; Augereau, B
2000-12-01
Old tears of the subscapular muscle situated in the glenoid area are not accessible to direct repair and require locoregional muscle plasty. The clavicular portion of the pectoralis major can be used for reconstruction. The purpose of this study was to describe the operative technique and examine short-term outcome. Five patients, mean age 54 years (45-71 years) with an irreparable tear of the subscapularis in the glenoid area with fatty degeneration greater than grade two in the Goutallier classification were treated. Four had had previous surgery for acromioplasty associated with rotator cuff repair in two or implantation of a humeral prosthesis in one. The preoperative Constant score was 27.5 (mean, range=8.5-54) due to invalidating pain, limited active mobility and reduced muscle force. Gerber's lift-off test was positive for those patients for whom it could be performed. Plain x-rays evidenced anterior subdislocation of the humeral head in one case. Subscapular reconstruction was achieved using the entire clavicular portion of the pectoralis major which was dissected and sectioned at its distal insertion on the humerus then reinserted by transosseous suture onto the lesser tuberosity. The rehabilitation program started with active and passive mobility against gravity within a few days of surgery using biofeedback contraction of the muscle flap then active contractions two months postoperatively. Patients were reviewed at a mean 19 months (6-42 months) for clinical and radiological assessment. Four patients had a painless shoulder with a negative lift-off test. The gain in active mobility was predominantly achieved with anterior elevation and abduction. Muscle force was weak leading to a low overall Constant score at revision (mean=50, range=30-63). Radiographically, the humeral head was centered exactly as on the preoperative films. There were no cases with a new anterior subdislocation nor an aggravation of a former subdislocation. Functional outcome was better in cases with a unique tear of the subscapularis. Open surgery is used for primary repair of recent tears of the subscapularis. This technique gives 80 p. 100 good and very good results. In case of symptomatic acromioclavicular osteoarthtisis, better long-term results can be obtained by using a tendodesis of the long biceps and resecting the lateral centimeter of the clavicle. In case of irreparable tears in the glenoid area, reconstruction by transfer of the clavicular portion of the pectoralis major can produce a stable painless shoulder with improved active moblity and normal clinical tests. This method provides anterior stability of the glenohumeral articulation and prevents any anterior subdislocation of the humeral head, thus protecting the joint from secondary degeneration.
Midander, Klara; Julander, Anneli; Kettelarij, Jolinde; Lidén, Carola
2016-11-01
Metal release from materials immersed in artificial sweat can function as a measure of potential skin exposure. Several artificial sweat models exist that, to various degree, mimic realistic conditions. Study objective was to evaluate metal release from previously examined and well characterized materials in two different artificial sweat solutions; a comprehensive sweat model intended for use within research, based on the composition of human sweat; and the artificial sweat, EN1811, intended for testing compliance with the nickel restriction in REACH. The aim was to better understand whether there are advantages using either of the sweat solutions in bio-elution testing of materials. Metal release in two different artificial sweat solutions was compared for discs of a white gold alloy and two hard metals, and a rock drilling insert of tungsten carbide at 1 h, 24 h, 1 week and 1 month. The released amount of metal was analysed by means of inductively coupled plasma mass spectrometry. Similar levels of released metals were measured from test materials in the two different artificial sweat solutions. For purposes in relation to legislations, it was concluded that a metal release test using a simple artificial sweat composition may provide results that sufficiently indicate the degree of metal release at skin contact. Copyright © 2016 Elsevier Inc. All rights reserved.
Chen, Chao; Zhao, Xinqing; Jin, Yingyu; Zhao, Zongbao Kent; Suh, Joo-Won
2014-11-01
Bacterial artificial chromosomal (BAC) vectors are increasingly being used in cloning large DNA fragments containing complex biosynthetic pathways to facilitate heterologous production of microbial metabolites for drug development. To express inserted genes using Streptomyces species as the production hosts, an integration expression cassette is required to be inserted into the BAC vector, which includes genetic elements encoding a phage-specific attachment site, an integrase, an origin of transfer, a selection marker and a promoter. Due to the large sizes of DNA inserted into the BAC vectors, it is normally inefficient and time-consuming to assemble these fragments by routine PCR amplifications and restriction-ligations. Here we present a rapid method to insert fragments to construct BAC-based expression vectors. A DNA fragment of about 130 bp was designed, which contains upstream and downstream homologous sequences of both BAC vector and pIB139 plasmid carrying the whole integration expression cassette. In-Fusion cloning was performed using the designer DNA fragment to modify pIB139, followed by λ-RED-mediated recombination to obtain the BAC-based expression vector. We demonstrated the effectiveness of this method by rapid construction of a BAC-based expression vector with an insert of about 120 kb that contains the entire gene cluster for biosynthesis of immunosuppressant FK506. The empty BAC-based expression vector constructed in this study can be conveniently used for construction of BAC libraries using either microbial pure culture or environmental DNA, and the selected BAC clones can be directly used for heterologous expression. Alternatively, if a BAC library has already been constructed using a commercial BAC vector, the selected BAC vectors can be manipulated using the method described here to get the BAC-based expression vectors with desired gene clusters for heterologous expression. The rapid construction of a BAC-based expression vector facilitates heterologous expression of large gene clusters for drug discovery. Copyright © 2014 Elsevier Inc. All rights reserved.
Bioengineered Lacrimal Gland Organ Regeneration in Vivo
Hirayama, Masatoshi; Tsubota, Kazuo; Tsuji, Takashi
2015-01-01
The lacrimal gland plays an important role in maintaining a homeostatic environment for healthy ocular surfaces via tear secretion. Dry eye disease, which is caused by lacrimal gland dysfunction, is one of the most prevalent eye disorders and causes ocular discomfort, significant visual disturbances, and a reduced quality of life. Current therapies for dry eye disease, including artificial tear eye drops, are transient and palliative. The lacrimal gland, which consists of acini, ducts, and myoepithelial cells, develops from its organ germ via reciprocal epithelial-mesenchymal interactions during embryogenesis. Lacrimal tissue stem cells have been identified for use in regenerative therapeutic approaches aimed at restoring lacrimal gland functions. Fully functional organ replacement, such as for tooth and hair follicles, has also been developed via a novel three-dimensional stem cell manipulation, designated the Organ Germ Method, as a next-generation regenerative medicine. Recently, we successfully developed fully functional bioengineered lacrimal gland replacements after transplanting a bioengineered organ germ using this method. This study represented a significant advance in potential lacrimal gland organ replacement as a novel regenerative therapy for dry eye disease. In this review, we will summarize recent progress in lacrimal regeneration research and the development of bioengineered lacrimal gland organ replacement therapy. PMID:26264034
Ye, J J; Yang, Y; Zhang, H J; Zheng, Y C; Pan, Y; Xie, H
2018-05-01
Objective: To investigate the necessity of artificial kidney seeper which made through inserting a ureteral tube in the ureter to the ultrasonography-guided percutaneous nephrolithotomy (PCNL). Methods: This was a randomized prospective study. Patients who conformed to the inclusion and exclusion criteria were enrolled at Department of Urology, Frist Affiliated Hospital of Wenzhou Medical University from January 2016 to May 2017. Totally 291 patients were included in the study. Patients were randomly assigned into two groups (artificial kidney seeper group and non-artificial kidney seeper group) in different kidney seeper level (5 to <10 mm, 10 to 20 mm) respectively. The artificial kidney seeper group was inserted by a ureteral cathedral, then were underwent the ultrasonography-guided PCNL in prone position. The non-artificial kidney seeper group were underwent the ultrasonography-guided PCNL in prone position directly. The t test, χ(2) test, repeated measure analysis was used to data measurement, respectively. Results: Four patients who diagnosed pyonephrosis were excluded. On the 5 to <10 mm level, fever rate (14.6% vs . 4.8%, χ(2)=5.07, P =0.03), operation time ((65.7±9.9)min vs . (50.3±7.4)min, t =11.47, P =0.00), cost ((18 327±903) yuan vs . (14 583±784) yuan, t =24.50, P =0.00) about artificial kidney seeper group and non-artificial kidney seeper group had statistical differences. And on the 10 to 20 mm level, fever rate (14.5% vs . 3.39%, χ(2)=4.53, P =0.03), operation time ((66.0±9.9)min vs . (52.4±8.9)min, t =8.30, P =0.00), cost ((16 548±537) yuan vs. (13 102±629) yuan, t =32.10, P =0.00) about artificial kidney seeper group and non-artificial kidney seeper group had statistical differences. And there were no statistical differences in the success rate of puncturing, the failures of the treatment to the stone pieces falling into the ureter and clearance rate of the stone and so on. In this study, 2 cases recovered after received transfusion and digital subtraction angiography artery embolization treatments; D-J tube was indwelled into 4 cases guiding by super smooth thread; 4 cases were finished the surgeries with the help of ureteroscopy, because the stone pieces fell into the ureter during the surgeries. And there was no patients developing septic shock, adjacent viscera injury or other serious complications. Conclusion: For seasoned doctors, there is no necessity of regularly artificial kidney seeper for PCNL when the pre-operation seeper ranging from 5 to 20 mm.
A comparison of basal and eye-flush tears for the analysis of cat tear proteins.
Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F
2011-02-01
To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
[Comparison of two kinds of artificial tears on the dry eye after phacoemulsification].
You, R; Wang, J; Han, Y; Liu, L J; Wang, W Y
2017-06-11
Objective: To compare the curative effect of two different artificial tears on dry eye after phacoemulsification. Methods: Prospective randomized controlled clinical trial. From March to June in 2012, 102 patients (102 eyes) with age-related cataract were treated with phacoemulsification at Beijing Tongren Hospital, Capital University of Medical Sciences, and these eyes were randomly divided into blank group (group A ) 32 cases, treatment group 1 (group B) 35 cases and treatment group 2 (group C) 35 cases. Group A was treated with conventional antibiotics. Group B was sodium hyaluronate eye drop, group C was lipid-containing carbomer gel respectively. All patients finished a dry eye questionnaire called Ocular Surface Disease Index (OSDI), and Schimmer's test (SIt), break up time (BUT) and fluorescein staining (FL) tests were performed before surgery and at 7, 30 and 90 days after surgery respectively. Optometry were performed at 90 days after surgery. The χ(2) test was used to analyze the sex of the patients, and the age of the patients was analyzed by one-way ANOVA. Partial data in eye tests and in OSDI does not meet the normal distribution. Therefore, they were analyzed by Kruskal-Wallis H test. If significant difference existed, these data were then analyzed by independent sample Wilcoxon rank sum test. Results: Twelve patients were lost to visit within 3 months. A total of 90 patients were followed up for 90 days. The mean age of all patients was (69.5±9.5) years (46.0-89.0 years), 38 males and 64 females. There were 30 patients in Group A, group B and group C respectively. The prevalence of dry eye was 56. 7% (60/102). There was no significant difference among the three groups ( P> 0.05). OSDI questionnaire showed that OSDI score was significantly different among the three groups at 7, 30 and 90 days after operation ( H =9.89, 55.53, 45.43, P< 0.05). At 30 and 90 days after operation, the median OSDI scores were 12.50 and 10.42 in group C, respectively, which were better than those of group A scores 27.09 and 20. 8 ( Z=- 6.30, -5.94, P< 0.05), and were better than those of group B scores 17.71 and 13. 54 ( Z=- 3.40, -3.52, P< 0.05). At 90 days after operation, the median BUT of B and C treatment groups was 9. 00, which was better than that of group A (4.00). The difference was statistically significant ( H =21.51, P< 0.05), There was no significant difference between group B and group C ( Z=- 0.34, P> 0.05). Conclusion: The treatment of artificial tears with lipid composition in the early stage after phacoemulsification is beneficial to the improvement of postoperative symptoms and signs of dry eye. (Chin J Ophthalmol, 2017, 53: 445-450) .
Non-axisymmetric Flows and Transport in the Edge of MST
NASA Astrophysics Data System (ADS)
Miller, Matthew Charles
Magnetic reconnection occurs in plasmas all throughout the universe and is responsible for spectacular and perplexing phenomena. In the Madison Symmetric Torus (MST) reversed field pinch (RFP), reconnection occurs as quasi-periodic bursts of tearing instabilities (saw-teeth), which give rise to a number of processes that affect the RFP's global behavior and confinement. This work examines the structure of turbulent plasma flow in the edge region and its role in affecting momentum and particle transport through the use of several insertable probes and novel ensemble techniques. Very few measurements exist of tearing mode flow structures. The flow structure has now been measured for m = 0 modes and is in good agreement with theoretical expectations for nonlinear resistive MHD calculated for the RFP using DEBS and NIMROD. The flows are predicted and measured to be different than the classical Sweet-Parker picture with symmetric inward flows. The flow fluctuations have a profound effect on momentum transport, which is trans- ported rapidly at the crash. This work advances the understanding of this process by measuring the Reynolds stress associated with turbulent flow. Combined with measurements of the Maxwell stress, a new picture for magnetic self-organization in the RFP via two-fluid physics has emerged. The Reynolds and Maxwell stresses are measured to be an order of magnitude larger than the rate of change in inertia but oppositely directed such that they almost cancel. Two-fluid effects are significant because of the relationship be- tween the Maxwell stress and the Hall dynamo, a term only existing in two-fluid theories. This relationship inextricably couples the momentum dynamics with the current dynamics. Indeed, the parallel momentum profile exhibits a relaxation at the crash akin to the relaxation seen in the parallel current density profile. Tearing modes also drive particle transport. Fluctuation-induced particle flux is resolved through a crash by measuring it directly as < neur>. The flux increases dramatically during a crash and is non-axisymmetric. Between crashes, the transport from tearing is small, which agrees with previous measurements that identified electrostatic transport as dominant at that time.
Use of BAC clones as standardized reagents for Marek’s disease virus research
USDA-ARS?s Scientific Manuscript database
The cloning of the Marek’s disease virus (MDV) genome as an infectious bacterial artificial chromosome (BAC) clone have led to major advances through our ability to study individual gene function by making precise insertions and deletions in the viral genome. We believe that MDV BAC clones will repl...
NASA Astrophysics Data System (ADS)
Han, Yu-Yan; Gong, Dunwei; Sun, Xiaoyan
2015-07-01
A flow-shop scheduling problem with blocking has important applications in a variety of industrial systems but is underrepresented in the research literature. In this study, a novel discrete artificial bee colony (ABC) algorithm is presented to solve the above scheduling problem with a makespan criterion by incorporating the ABC with differential evolution (DE). The proposed algorithm (DE-ABC) contains three key operators. One is related to the employed bee operator (i.e. adopting mutation and crossover operators of discrete DE to generate solutions with good quality); the second is concerned with the onlooker bee operator, which modifies the selected solutions using insert or swap operators based on the self-adaptive strategy; and the last is for the local search, that is, the insert-neighbourhood-based local search with a small probability is adopted to improve the algorithm's capability in exploitation. The performance of the proposed DE-ABC algorithm is empirically evaluated by applying it to well-known benchmark problems. The experimental results show that the proposed algorithm is superior to the compared algorithms in minimizing the makespan criterion.
Wang, Zunde; Engler, Peter; Longacre, Angelika; Storb, Ursula
2001-01-01
Large-scale genomic sequencing projects have provided DNA sequence information for many genes, but the biological functions for most of them will only be known through functional studies. Bacterial artificial chromosomes (BACs) and P1-derived artificial chromosomes (PACs) are large genomic clones stably maintained in bacteria and are very important in functional studies through transfection because of their large size and stability. Because most BAC or PAC vectors do not have a mammalian selection marker, transfecting mammalian cells with genes cloned in BACs or PACs requires the insertion into the BAC/PAC of a mammalian selectable marker. However, currently available procedures are not satisfactory in efficiency and fidelity. We describe a very simple and efficient procedure that allows one to retrofit dozens of BACs in a day with no detectable deletions or unwanted recombination. We use a BAC/PAC retrofitting vector that, on transformation into competent BAC or PAC strains, will catalyze the specific insertion of itself into BAC/PAC vectors through in vivo cre/loxP site-specific recombination. PMID:11156622
De Smet, A A; Graf, B K
1994-04-01
MR imaging of the knee is a valuable technique for diagnosing meniscal tears, but some tears found at arthroscopy are not shown on MR imaging. The purpose of this study was to determine whether or not tears were more frequently missed in the presence of an anterior cruciate ligament tear or when tears had certain locations or configurations. We reviewed the original MR reports and surgical records of 400 patients who had both an MR examination and arthroscopy of the knee. Using chi 2 analysis, we examined how the sensitivity for detecting meniscal tears varied with the presence of a tear of the anterior cruciate ligament, with the location of the tear within the meniscus, and among six configurations of meniscal tears. We also studied whether sensitivity decreased with an increasing delay between MR examination and arthroscopy. In the presence of a tear of the anterior cruciate ligament, the sensitivity decreased from 0.97 to 0.88 (p = .016) for medial meniscal tears and from 0.94 to 0.69 (p = .0005) for lateral tears. The overall sensitivity for lateral meniscal tears was significantly less for posterior (p = .001) and peripheral (p = .005) tears than for other tear locations or configurations. The sensitivities did not significantly differ between tear locations and configurations in the medial meniscus or with an increasing delay until arthroscopy. Patients with a torn anterior cruciate ligament were more likely to have peripheral tears of the medial meniscus (p = .00004) and posterior (p = .0004) and peripheral (p = .04) tears of the lateral meniscus. Because of their location and configuration, meniscal tears associated with an anterior cruciate ligament injury are more difficult to detect on MR images than are tears in knees with an intact ligament. If a tear of the anterior cruciate ligament is detected, special attention should be given to the subtle peripheral tears that may be present in either meniscus, but most commonly in the posterior horn of the lateral meniscus. These tears are especially difficult to detect on MR images.
Self-diagnosis of damage in fibrous composites using electrical resistance measurements
NASA Astrophysics Data System (ADS)
Kang, Ji Ho; Paty, Spandana; Kim, Ran Y.; Tandon, G. P.
2006-03-01
The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in situ damage detection and sensing in carbon fiber reinforced plastic (CFRP) composite structures. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested and post-processed with the measurement data. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. Encouraged by the results of coupon specimens, we implemented the measurement system on panel specimens. Three different quasi-isotropic panels were designed and manufactured: a panel with artificial delamination by inserting Teflon film at the midplane, a panel with artificial delamination by inserting Teflon film between the second and third plies from the surface, and an undamaged panel. The first two panels were designed to determine the feasibility of detecting delamination using the developed measurement system. The third panel had no damage at first, and then three different sizes of holes were drilled at a chosen location. Panels were prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrode connections for a panel. All possible pairs of electrodes were scanned and the resistance was measured for each pair. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.
Tear dynamics in healthy and dry eyes.
Cerretani, Colin F; Radke, C J
2014-06-01
Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.
The tear turnover and tear clearance tests - a review.
Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño
2018-03-01
The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.
Calcium-enriched mixture cement as artificial apical barrier: A case series
Nosrat, Ali; Asgary, Saeed; Eghbal, Mohammad Jafar; Ghoddusi, Jamileh; Bayat-Movahed, Saeed
2011-01-01
In comparison to the conventional apexification using calcium hydroxide, artificial apical barrier technique is more valuable and less time consuming. This article describes successful use of calcium-enriched mixture (CEM) cement as an artificial apical barrier in open apices. In this study, 13 single-rooted teeth with necrotic pulps and open apices were treated non-surgically. After copious irrigation of the root canals with NaOCl 5.25% and gentle filing, based on need for interappointment dressing, treatments were followed by CEM cement (BioniqueDent, Tehran, Iran) apical plug insertion in the first or second appointment. All cases were then permanently restored. All subjects were followed until radiographic evidence of periradicular healing was seen (mean 14.5 months). Clinically, all cases were functional and asymptomatic and complete osseous healing was observed in all the teeth. Considering the biological properties of CEM cement, this new endodontic biomaterial might be appropriate to be used as artificial apical barrier in the open apex teeth. PMID:22144818
Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun
2017-07-01
The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P < 0.001). Logistic regression revealed that having a full-thickness tear was the most reliable risk factor for tear progression (P < 0.001). This study found that 28/34 (82.4%) of symptomatic full-thickness rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be monitored more carefully for progression than partial-thickness tears. IV.
Yamamoto, Nobuyuki; Mineta, Mitsuyoshi; Kawakami, Jun; Sano, Hirotaka; Itoi, Eiji
2017-09-01
The risk factors for tear progression in symptomatic rotator cuff tears have not been clarified yet. It is important for orthopaedic surgeons to know the natural course of tear progression when nonoperative management is to be chosen. Tears in younger patients, high-activity patients, or heavy laborers would progress in size more than those in older patients, low-activity patients, or light laborers. Case-control study; Level of evidence, 3. Two hundred twenty-five consecutive patients with symptomatic rotator cuff tears visited our institute between 2009 and 2015. Of these, 174 shoulders of 171 patients (mean age, 66.9 years) who underwent at least 2 magnetic resonance imaging (MRI) examinations were prospectively enrolled. The mean follow-up was 19 months. Tear progression was defined as positive when the tear size increased by ≥2 mm. The demographic factors that were analyzed by multivariate analysis included age, sex, hand dominance, smoking, alcohol drinking, hypercholesterolemia, sports participation, job type, tear size, and tear type (full or partial thickness). Of the 174 shoulders, 82 shoulders (47%) showed tear progression. The mean (±SD) tear length and width in the progression group on final MRI were 23.1 ± 12.5 mm and 17.3 ± 9.6 mm, respectively; the tear size progressed by a mean 5.8 ± 5.6 mm in length and 3.1 ± 5.2 mm in width. The mean propagation speed was 3.8 mm/y in length and 2.0 mm/y in width. The size of full-thickness tears significantly increased compared with that of articular-sided partial-thickness tears ( P = .0215). The size of medium tears significantly increased compared with that of other tears ( P < .0001). According to the logistic regression analysis, smoking was significantly correlated with tear progression ( P = .026). Subgroup analyses showed that male sex, hand dominance, and trauma were correlated with tear progression. Age, alcohol drinking, hypercholesterolemia, sports participation, and job type did not show any correlation with tear progression. The tear size of symptomatic rotator cuff tears progressed in 47% of the shoulders during a mean of 19 months, and the speed of progression was 3.8 mm/y in length and 2.0 mm/y in width. The risk factors for tear progression were (1) a medium-sized tear, (2) a full-thickness tear, and (3) smoking.
Validation of an improved abnormality insertion method for medical image perception investigations
NASA Astrophysics Data System (ADS)
Madsen, Mark T.; Durst, Gregory R.; Caldwell, Robert T.; Schartz, Kevin M.; Thompson, Brad H.; Berbaum, Kevin S.
2009-02-01
The ability to insert abnormalities in clinical tomographic images makes image perception studies with medical images practical. We describe a new insertion technique and its experimental validation that uses complementary image masks to select an abnormality from a library and place it at a desired location. The method was validated using a 4-alternative forced-choice experiment. For each case, four quadrants were simultaneously displayed consisting of 5 consecutive frames of a chest CT with a pulmonary nodule. One quadrant was unaltered, while the other 3 had the nodule from the unaltered quadrant artificially inserted. 26 different sets were generated and repeated with order scrambling for a total of 52 cases. The cases were viewed by radiology staff and residents who ranked each quadrant by realistic appearance. On average, the observers were able to correctly identify the unaltered quadrant in 42% of cases, and identify the unaltered quadrant both times it appeared in 25% of cases. Consensus, defined by a majority of readers, correctly identified the unaltered quadrant in only 29% of 52 cases. For repeats, the consensus observer successfully identified the unaltered quadrant only once. We conclude that the insertion method can be used to reliably place abnormalities in perception experiments.
Structure and microanalysis of tear film ferning of camel tears, human tears, and Refresh Plus.
Am, Masmali; Ra, Fagehi; El-Naggar, Ahmad H; Tm, Almubrad
2018-01-01
This study aimed to investigate the tear ferning pattern and chemical elements of the tear film of camel tears compared with human tears and Refresh Plus eye lubricant. Refresh Plus was used as a control because it provides a healthy ferning pattern, due to the presence of an optimum ratio of carboxymethylcellulose (CMC) sodium and electrolytes. The main research focus is elucidating the viability of camel tear film in the dry, harsh environment of the desert. The tears were collected from five camels, five male desert workers (20-25 years old) at a small village located 100 km from Riyadh, Saudi Arabia, and five male subjects (20-25 years old) from Riyadh. A small drop (1 μl) of tears was dried on a glass slide and observed under a light (Olympus BX1) and scanning electron microscope (Inspect S50, Field Electron and Ion Company [FEI]). Energy-dispersive X-ray spectroscopy (EDS) of the tear film and Refresh Plus were investigated with a JEOL 1400 scanning transmission electron microscope. The camel tear film pattern was surrounded by thick, peripheral, homogenous layers containing small oily droplets, particles, and tiny branches in the tear ferning. The tear ferning of the camel was grade 0-1, whereas the tear ferning of human tears and Refresh Plus was grade 1-2. The mass percentage of chloride was highest in the camel tears. The mass percentage of potassium in the camel tears was greater than that in the human tears, but it was less than that in the Refresh Plus lubricant. Camel tears exhibit a better quality than human tears and Refresh Plus lubricant do. The presence of oily droplet-like structures at the periphery of tear ferning suggests that camel tear film may have a higher quality and quantity of minerals and lubricants, which may help the animal to avoid eye dryness. Future work is required to investigate the identification of the elements present in the peripheral and central part of the tear ferning.
Igarashi, Akihito; Kamiya, Kazutaka; Kobashi, Hidenaga; Shimizu, Kimiya
2015-08-01
To assess the changes in intraocular scattering before and after instillation of rebamipide ophthalmic suspension in patients with dry eye after corneal refractive surgery. This study enrolled 60 eyes of 30 dry eye patients undergoing corneal refractive surgery. Patients were randomly assigned to start topical administration of rebamipide ophthalmic suspension (rebamipide group) or artificial tears (control group) 4 times daily for 4 weeks. Tear secretion, tear break-up time (TBUT), and the fluorescein score were measured before and after treatment. Intraocular light scattering was also measured as the objective scattering index (OSI) at 0.5-second intervals over 10 seconds. In the rebamipide group, the Schirmer I test, TBUT, and fluorescein score improved significantly, from 11.4 ± 9.0 mm, 2.2 ± 0.7 seconds, and 4.3 ± 1.3 to 14.9 ± 7.4 mm, 4.5 ± 1.7 seconds, and 1.9 ± 1.0, respectively (P = 0.006, P < 0.001, P < 0.001, Wilcoxon signed rank test). We found significant improvements in OSI at 5.0 to 10.0 seconds after blinking (5-8 seconds, P = 0.01; 9 seconds, P = 0.02; 10 seconds, P < 0.001). The mean OSI, the OSI change rate, and the OSI slope of the linear regression line improved significantly, from 2.73 ± 1.52, 74.7 ± 69.5%, and 0.10 ± 0.12 to 2.19 ± 1.19, 28.6 ± 48.7%, and 0.04 ± 0.08, respectively (P = 0.02, 0.003, and 0.03). Rebamipide ophthalmic suspension was effective for improving both ocular surface parameters and optical quality in patients with dry eye undergoing corneal refractive surgery, suggesting that it may hold promise for the treatment of such patients.
Matoba, Alice Y; Peterson, Jeff R; Wilhelmus, Kirk R
2016-03-01
To describe dendritiform keratopathy associated with exposure to polyquaternium-1, a common preservative found in contact lens solutions and tear replacement products. Case series. Sixteen patients who demonstrated dendritiform keratopathy during topical ophthalmic exposure to polyquaternium-1. Records were reviewed of all patients diagnosed with dendritiform keratopathy between 1999 and 2014 who had documented exposure to contact lens care disinfecting solutions or artificial tear solutions containing polyquaternium-1. Patients were excluded who had coexisting potential causes for dendritiform keratopathy, such as prior herpes simplex keratitis, varicella-zoster viral keratitis, the linear form of Thygeson's superficial keratitis, epithelial regeneration line, Acanthamoeba keratitis, mucus plaque keratopathy, medication-related keratopathy, or limbal stem cell deficiency characterized by conjunctivalization of the corneal epithelium. Effect of discontinuation of exposure to polyquaternium-1 on the dendritiform keratopathy. Sixteen patients demonstrated dendritiform keratopathy after exposure to the preservative polyquaternium-1. Thirteen patients had a history of recent exposure to contact lens disinfecting solutions (Opti-Free, Equate) containing polyquaternium-1. Three patients used a tear replacement product (Systane) containing a polyquaternium-1 preservative. Four patients were treated with antiviral medications for presumed herpes simplex keratitis; 4 patients underwent diagnostic testing for Acanthamoeba keratitis. Two additional patients were diagnosed sequentially with herpes simplex keratitis, then Acanthamoeba keratitis before referral. All dendritiform lesions resolved within 2 to 6 weeks after elimination of exposure to polyquaternium-1. Ophthalmic products containing polyquaternium-1 may cause dendritiform keratopathy that may be confused with infections of the superficial cornea, such as herpes simplex virus keratitis or Acanthamoeba keratitis. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Tagawa, Yoshiaki; Namba, Kenichi; Nakazono, Yumi; Iwata, Daiju; Ishida, Susumu
2017-04-01
The efficacy of epinastine 0.05% ophthalmic solution for pollen allergic conjunctivitis has already been shown in a conjunctival allergen challenge (CAC) test using cedar pollen as a challenge. The present study investigated the efficacy of this solution against birch pollen conjunctivitis in a CAC test. Ten adult subjects (eight males and two females) with asymptomatic birch pollen conjunctivitis were enrolled in this study. The average age of the subjects was 41.1 years. This study was conducted during a period without birch pollen dispersion. In each subject, the epinastine 0.05% ophthalmic solution was instilled in one eye, and an artificial tear fluid was instilled in the fellow eye in a double-blind manner. Five minutes or 4 h after the drug instillation, both eyes were challenged with an optimal concentration of birch pollen, and ocular itching and conjunctival hyperemia were then graded. Tears were collected before the drug instillation and 20 min after the pollen challenge, and the histamine level was measured. The ocular itching scores and palpebral conjunctival hyperemia scores of the epinastine-treated eyes were significantly lower than those of the contralateral control eyes when the eyes were pretreated with the drug 4 h before the CAC. There was a significant correlation between the tear histamine level and mean ocular itching score of three time points (3, 5 and 10 min) following the CAC in the control eyes but not the epinastine-treated eyes. Epinastine is effective in suppressing ocular itching and conjunctival hyperemia in birch pollen conjunctivitis. Copyright © 2017 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.
Arimoto, Atsushi; Kitagawa, Kazuko; Mita, Norihiro; Takahashi, Yoriko; Shibuya, Eri; Sasaki, Hiroshi
2014-08-01
The aim of this study was to investigate the efficacy of 2% rebamipide suspension in treatment of keratoconjunctivitis sicca (KCS) in patients with Sjögren syndrome (SS) with or without punctal occlusions. Thirty patients with SS, diagnosed based on the presence of autoantibodies and/or focus score >1 on lip biopsies, with corneal fluorescein staining scores (FSS) >3, and conjunctival lissamine green-staining scores (LSS) >3, were treated 4 times daily for 4 weeks with 2% rebamipide ocular suspension. Ocular examinations were performed before treatment and 2 and 4 weeks after treatment to evaluate FSS (0-9), LSS (0-6), and tear film break-up time (BUT). Hyaluronate and/or artificial tears were not discontinued. The patients were interviewed regarding the 5 major KCS symptoms, foreign body sensation, dry eye sensation, photophobia, ocular pain, and blurred vision, with each graded from none (0) to very severe (4). Of the 30 patients, 3 failed to attend all sessions, leaving 27 (25 females, 2 males, mean age 62.5 ± 10.8 years) to be studied. FSS and LSS showed improvement at week 2, but BUT showed improvement later, at week 4. All 5 symptoms improved significantly. When the patients were divided into 3 groups according to the presence of punctal occlusions, FSS and LSS were found to improve in all groups, but BUT improved only in patients with both puncta occluded at week 4. Rebamipide ophthalmic suspension was effective in treating KCS of patients with SS, probably by increasing mucins and suppressing inflammatory cytokines. Punctal occlusions resulted in sufficient retention of tear fluid to enhance the activities of rebamipide and improve BUT.
Artificial atlanto-odontoid joint replacement through a transoral approach.
Lu, Bin; He, Xi Jing; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong
2009-01-01
Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1-C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P B 0.021) and NZ (P B 0.002) and a significantly increased stiffness (P \\ 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P C 0.719), NZ (P C 0.580), and stiffness (P C 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities.
Artificial atlanto-odontoid joint replacement through a transoral approach
Lu, Bin; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong
2008-01-01
Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1–C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P ≤ 0.021) and NZ (P ≤ 0.002) and a significantly increased stiffness (P < 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P ≥ 0.719), NZ (P ≥ 0.580), and stiffness (P ≥ 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities. PMID:19043745
Plasminogen activator activity in tears of pregnant women.
Csutak, Adrienne; Steiber, Zita; Tőzsér, József; Jakab, Attila; Berta, András; Silver, David M
2017-01-01
Plasminogen activator activity (PAA) in tears of pregnant women was investigated at various gestation times to assess the availability of plasminogen activator for aiding potential corneal wound healing processes during pregnancy. PAA was measured by a spectrophotometric method. The analysis used 91 tear samples from pregnant and non-pregnant women, supplemented with 10 additional tear PAA measurements from non-pregnant women obtained in a previous study. Tear levels of PAA in pregnant women formed a bimodal distribution. Either the tear PAA level was zero or non-zero during pregnancy. When non-zero, the tear PAA level was dissociated from gestation time and not different than non-pregnant and post-pregnant levels. The frequency of occurrence of zero level tear PAA increased with gestation: 16%, 17% and 46% had zero tear PAA in samples taken from women in the first, second and third trimester, respectively. Overall, of the tear samples taken from women during pregnancy, a total of 26% were at zero tear PAA. The remaining tear samples had non-zero tear PAA values throughout gestation equivalent to non-pregnant tear PAA values, suggesting local control of the source of PAA in tears. Given the importance of the plasminogen activator system in tears to wound healing in the cornea, and the high occurrence of zero tear PAA in our sample of pregnant women, elective corneal surgery would be contraindicated. If corneal surgery is nevertheless necessary, the tear PAA level would be worth checking and patients with low level should be closely observed during the postoperative period.
Keratoconus presenting with bilateral simultaneous acute corneal hydrops.
Bilgin, Burak; Unal, Betül; Unal, Mustafa; Doğan, Erkan; Cetinkaya, Aslı; Akyol, Mahmut; Yücel, Iclal; Akar, Yusuf; Apaydın, Cemil; Ilhan, Deniz
2013-04-01
To report a case of unknown keratoconus presenting with bilateral simultaneous acute corneal hydrops. Case report. A case of a 12-year-old male patient with Leber congenital amaurosis (LCA) presented with sudden whitening and lacrimation for 2 days in both eyes simultaneously. At the initial examination, there were bilateral acute corneal hydrops, enophthalmic eyes and roving nystagmus. Ultrasonography revealed clear crystalline lenses and attached retina. Initial management consisted of topical hypertonic solutions, steroids and artificial tears. Bilateral simultaneous acute corneal hydrops has not been reported before in the literature. It may be the presenting sign of keratoconus. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
"To wipe a manly tear": the aesthetics of emotion in Victorian narrative painting.
Fletcher, Pamela
2009-01-01
Over the course of the twentieth century, Victorian narrative painting became synonymous with sentimentality, melodrama, and the artificial evocation of emotion. This essay aims to complicate this familiar assessment by examining the role of emotional effect played in aesthetic evaluations of some of the most popular modern life genre paintings of the 1850s to 1870s. I argue that the critical discourse on Victorian narrative painting was marked by a persistent skepticism about the role of feeling in aesthetic response -- as excessively painful or obvious emotional impact marked the limit between artistic success and failure -- and I locate these concerns within the physical and social exhibition culture of the Royal Academy.
Herbal Supplement in a Buffer for Dry Eye Syndrome Treatment.
Chen, Hung-Chang; Chen, Zhi-Yu; Wang, Tsung-Jen; Drew, Victor J; Tseng, Ching-Li; Fang, Hsu-Wei; Lin, Feng-Huei
2017-08-03
Dry eye syndrome (DES) is one of the most common types of ocular diseases. There is a major need to treat DES in a simple yet efficient way. Artificial tears (AT) are the most commonly used agents for treating DES, but are not very effective. Herbal extractions of ferulic acid (FA), an anti-oxidant agent, and kaempferol (KM), an anti-inflammatory reagent, were added to buffer solution (BS) to replace ATs for DES treatment. The cytotoxicity and anti-inflammatory effects were examined in vitro by co-culture with human corneal epithelial cells (HCECs) to obtain the optimal concentration of KM and FA for treating HCECs. Physical properties of BS, such as pH value, osmolality, and refractive index were also examined. Then, rabbits with DES were used for therapeutic evaluation. Tear production, corneal damage, and ocular irritation in rabbits' eyes were examined. The non-toxic concentrations of KM and FA for HCEC cultivation over 3 days were 1 µM and 100 µM, respectively. Live/dead stain results also show non-toxicity of KM and FA for treating HCECs. Lipopolysaccharide-stimulated HCECs in inflammatory conditions treated with 100 µM FA and 1 µM KM (FA100/KM1) showed lower IL-1B , IL-6 , IL-8 , and TNFα expression when examined by real-time PCR. The BS with FA100/KM1 had neutral pH, and a similar osmolality and refractive index to human tears. Topical delivery of BS + FA100/KM1 showed no irritation to rabbit eyes. The corneal thickness in the BS + FA100/KM1 treated group was comparable to normal eyes. Results of DES rabbits treated with BS + FA100/KM1 showed less corneal epithelial damage and higher tear volume than the normal group. In conclusion, we showed that the combination of FA (100 µM) and KM (1 µM) towards treating inflamed HCECs had an anti-inflammatory effect, and it is effective in treating DES rabbits when BS is added in combination with these two herbal supplements and used as a topical eye drop.
NASA Astrophysics Data System (ADS)
Haines, Carter S.; Lima, Márcio D.; Li, Na; Spinks, Geoffrey M.; Foroughi, Javad; Madden, John D. W.; Kim, Shi-Hyeong; Fang, Shaoli; Jung de Andrade, Monica; Göktepe, Fatma; Göktepe, Ozer; Mirvakili, Seyed M.; Naficy, Sina; Lepró, Xavier; Oh, Jiyoung; Kozlov, Mikhail E.; Kim, Seon Jeong; Xu, Xiuru; Swedlove, Benjamin J.; Wallace, Gordon G.; Baughman, Ray H.
2014-03-01
High-performance artificial muscles have been produced from fibers having highly anisotropic thermal expansion. Inserting twist into these precursor fibers enables thermally-driven torsional actuation and can cause the formation of helical coils. Such coiled structures provide giant-stroke tensile actuation exceeding the 20% in-vivo contraction of natural muscles. This contraction is highly reversible, with over one million cycles demonstrated, and can occur without the hysteresis that plagues competing shape-memory and piezoelectric muscles. Several materials and composites are investigated, including low-cost, commercially-available muscle precursors, potentially facilitating thermally-responsive textiles that change porosity to provide wearer comfort.
NASA Astrophysics Data System (ADS)
Cui, Xianghong; Jin, Yunxue; Chen, Wei; Zhang, Qiuyang; Wang, Shuqi
2018-03-01
A self-lubricated oxide-containing tribo-layer was induced to form by continuously adding particles of MoS2, Fe2O3 or their mixtures onto sliding interfaces of AISI H13 and 52100 steels. The artificial tribo-layer was always noticed to form continuously and cover the worn surface (termed as cover-type), whereas the original tribo-layer spontaneously formed with no additive was usually discontinuous and inserted into the substrate (termed as insert-type). Clearly, the cover-type and insert-type tribo-layers exactly corresponded to low and high wear rates, respectively. For the mixed additives of Fe2O3 + MoS2, the protective tribo-layers presented a load-carrying capability and lubricative function, which are attributed to the existence of Fe2O3 and MoS2. Hence, the wear rates and friction coefficients of H13 steel were markedly reduced.
2014-01-01
Objective: We report the prevalence of surgical intervention on shoulder labral lesions detected at MR examinations and how surgeons describe labral tears seen at MR examinations in their arthroscopy reports. Methods: A retrospective review of 100 consecutive patients aged 50 years or younger who had shoulder labral tears on MR and went on to have surgery performed. It was determined whether surgical intervention was performed on the MR lesions. Results: Of these 100 patients, 72 had superior labral anterior to posterior (SLAP) tears, 38 had posterior labral tears and 28 had anterior labral tears on MR examination. All 100 patients went on to arthroscopy. All lesions described on MRI were described on arthroscopy. Of the 72 SLAP tears, 64 were described as fraying on arthroscopy with 51 debrided. The remaining eight SLAP tears were tacked surgically. Of the 38 posterior labral tears, 36 were described as fraying on arthroscopy with 29 debrided and 2 had surgical tacking performed. Of the 28 anterior labral tears described on MR examination, 26 had surgical tacking performed and 2 were debrided. There were four SLAP tears, two anterior labral tears and three posterior labral tears seen on arthroscopy but not seen on MR examination. Conclusion: In this series, a high percentage of SLAP tears and posterior labral tears described on MR examination did not have surgical tacking. Most anterior labral tears had surgical tacking. Based on the above, our surgeons request we describe superior and posterior labral lesions as fraying and/or tearing, unless we can see a displaced tear. Most anterior labral lesions are treated with surgical tacking. Advances in knowledge: MRI allows for sensitive detection of labral tears. The tears often are not clinically significant. PMID:24712320
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gust, Devens; Moore, Thomas A.; Moore, Ana L.
OAK B188 The goal of this project is to mimic the energy transduction processes by which photosynthetic organisms harvest sunlight and convert it to forms of energy that are more easily used and stored. The results may lead to new technologies for solar energy harvesting based on the natural photosynthetic process. They may also enrich our understanding and control of photosynthesis in living organisms, and lead to methods for increasing natural biomass production, carbon dioxide removal, and oxygen generation. In our work to date, we have learned how to make synthetic antenna and reaction center molecules that absorb light andmore » undergo photoinduced electron transfer to generate long-lived, energetic charge-separated states. We have assembled a prototype system in which artificial reaction centers are inserted into liposomes (artificial cell-like constructs), where they carry out light-driven transmembrane translocation of hydrogen ions to generate proton motive force. By insertion of natural ATP synthase into the liposomal bilayer, this proton motive force has been used to power the synthesis of ATP. ATP is a natural biological energy currency. We are carrying out a systematic investigation of these artificial photosynthetic energy harvesting constructs in order to understand better how they operate. In addition, we are exploring strategies for reversing the direction of the light-powered proton pumping. Most recently, we have extended these studies to develop a light-powered transmembrane calcium ion pump that converts sunlight into energy stored as a calcium ion concentration gradient across a lipid bilayer.« less
Assessment of Passive Intestinal Permeability Using an Artificial Membrane Insert System.
Berben, Philippe; Brouwers, Joachim; Augustijns, Patrick
2018-01-01
Despite reasonable predictive power of current cell-based and cell-free absorption models for the assessment of intestinal drug permeability, high costs and lengthy preparation steps hamper their use. The use of a simple artificial membrane (without any lipids present) as intestinal barrier substitute would overcome these hurdles. In the present study, a set of 14 poorly water-soluble drugs, dissolved in 2 different media (fasted state simulated/human intestinal fluids [FaSSIF/FaHIF]), were applied to the donor compartment of an artificial membrane insert system (AMI-system) containing a regenerated cellulose membrane. Furthermore, to investigate the predictive capacity of the AMI-system as substitute for the well-established Caco-2 system to assess intestinal permeability, the same set of 14 drugs dissolved in FaHIF were applied to the donor compartment of a Caco-2 system. For 14 drugs, covering a broad range of physicochemical parameters, a reasonable correlation between both absorption systems was observed, characterized by a Pearson correlation coefficient r of 0.95 (FaHIF). Using the AMI-system, an excellent predictive capacity of FaSSIF as surrogate medium for FaHIF was demonstrated (r = 0.96). Based on the acquired data, the AMI-system appears to be a time- and cost-effective tool for the early-stage estimation of passive intestinal permeability for poorly water-soluble drugs. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Highly stable maintenance of a mouse artificial chromosome in human cells and mice.
Kazuki, Kanako; Takehara, Shoko; Uno, Narumi; Imaoka, Natsuko; Abe, Satoshi; Takiguchi, Masato; Hiramatsu, Kei; Oshimura, Mitsuo; Kazuki, Yasuhiro
2013-12-06
Human artificial chromosomes (HACs) and mouse artificial chromosomes (MACs) display several advantages as gene delivery vectors, such as stable episomal maintenance that avoids insertional mutations and the ability to carry large gene inserts including the regulatory elements. Previously, we showed that a MAC vector developed from a natural mouse chromosome by chromosome engineering was more stably maintained in adult tissues and hematopoietic cells in mice than HAC vectors. In this study, to expand the utility for a gene delivery vector in human cells and mice, we investigated the long-term stability of the MACs in cultured human cells and transchromosomic mice. We also investigated the chromosomal copy number-dependent expression of genes on the MACs in mice. The MAC was stably maintained in human HT1080 cells in vitro during long-term culture. The MAC was stably maintained at least to the F8 and F4 generations in ICR and C57BL/6 backgrounds, respectively. The MAC was also stably maintained in hematopoietic cells and tissues derived from old mice. Transchromosomic mice containing two or four copies of the MAC were generated by breeding. The DNA contents were comparable to the copy number of the MACs in each tissue examined, and the expression of the EGFP gene on the MAC was dependent on the chromosomal copy number. Therefore, the MAC vector may be useful not only for gene delivery in mammalian cells but also for animal transgenesis. Copyright © 2013 Elsevier Inc. All rights reserved.
How should initial fit inform soft contact lens prescribing.
Boychev, Nikolay; Laughton, Deborah S; Bharwani, Gulshan; Ghuman, Hafsa; Wolffsohn, James S
2016-06-01
To investigate how initial HEMA and silicone-hydrogel (SiHy) contact lens fit on insertion, which informs prescribing decisions, reflect end of day fit. Thirty participants (aged 22.9±4.9 years) were fitted contralaterally with HEMA and SiHy contact lenses. Corneal topography and tear break-up time were assessed pre-lens wear. Centration, lag, post-blink movement during up-gaze and push-up recovery speed were recorded after 5,10,20min and 8h of contact lens wear by a digital slit-lamp biomicroscope camera, along with reported comfort. Lens fit metrics were analysed using bespoke software. Comfort and centration were similar with the HEMA and SiHy lenses (p>0.05), but comfort decreased with time (p<0.01) whereas centration remained stable (F=0.036, p=0.991). Movement-on-blink and lag were greater with the HEMA than the SiHy lens (p<0.01), but movement-on-blink decreased with time after insertion (F=22.423, p<0.001) whereas lag remained stable (F=1.967, p=0.129). Push-up recovery speed was similar with the HEMA and the SiHy lens 5-20min after insertion (p>0.05), but was slower with SiHy after 8h wear (p=0.016). Lens movement on blink and push-up recovery speed was predictive of the movement after 8h of wear after 10-20min SiHy wear, but after 5 to 20min of HEMA lens wear. A HEMA or SiHy contact lens with poor movement on blink/push-up after at least 10min after insertion should be rejected. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Mansori, Ashraf El; Lording, Timothy; Schneider, Antoine; Dumas, Raphael; Servien, Elvire; Lustig, Sebastien
2018-05-26
Injury to the anterior cruciate ligament (ACL) is frequently accompanied by tears of the menisci. Some of these tears occur at the time of injury, but others develop over time in the ACL-deficient knee. The aim of this study was to evaluate the effects of the patient characteristics, time from injury (TFI), and posterior tibial slope (PTS) on meniscal tear patterns. Our hypothesis was that meniscal tears would occur more frequently in ACL-deficient knees with increasing age, weight, TFI, PTS, and in male patients. Of the ACL-injured patients, 362 were analyzed, and details of meniscal lesions were collected. The medial and lateral tibial slopes (MTS, LTS) were measured via computed tomography. Patient demographics, TFI, MTS, and LTS were correlated with the diagnosed meniscal tears. Of the patients, 113 had a medial meniscus (MM) tear, 54 patients had a lateral meniscus (LM) tear, 34 patients had tears of both menisci, and 161 patients had no meniscal tear. The most common tear location was the posterior horn (PH) of the MM, followed by tear involving the whole MM. Patient age, BMI, and TFI were significantly associated with the incidence of MM tear. Female patients had a higher incidence of injury than males in all tear sites except in the body and PH. Male patients had more vertical and peripheral tears. The median MTS and LTS for patients with MM tears were 7.0°and 8.7°, respectively, while those of patients with LM tears were 6.9° and 8.1°. Steeper LTS was significantly associated with tears of LM and of both menisci. Older age, male sex, increased BMI, and prolonged TFI were significant factors for the development of MM tears. An increase in the tibial slope, especially of the lateral plateau, seems to increase the risk of tear of the LM and of both menisci. Level III.
Koike, Yoichi; Sano, Hirotaka; Kita, Atushi; Itoi, Eiji
2013-09-01
Some patients with rotator cuff tears complain of pain, whereas others are asymptomatic. Previous studies have pointed out the presence of active bone metabolism in the painful shoulder, identified with increased radioisotope uptake during bone scintigraphy. Shoulders with symptomatic rotator cuff tears will demonstrate higher radioisotope uptake than shoulders with asymptomatic tears with bone scintigraphy, reflecting active bone metabolism in symptomatic tears. Cross-sectional study; Level of evidence, 3. The study consisted of 3 groups: patients with symptomatic tears (symptomatic group), patients with asymptomatic tears (asymptomatic group), and controls (no tear group). The symptomatic group consisted of 28 shoulders from 28 patients with symptomatic rotator cuff tears (pain score ≤4 on the University of California, Los Angeles [UCLA] shoulder evaluation form) who underwent bone scintigraphy followed by rotator cuff repair. Of 70 volunteers who had previously undergone bone scintigraphy for diseases unrelated to their shoulder, 34 were selected for the asymptomatic group (pain score ≥8 on the UCLA shoulder form), and 32 were selected for the no tear group. The mean radioisotope uptake in the symptomatic group was significantly higher than that in the asymptomatic group (P = .02) and the no tear group (P = .02). Ten of 28 shoulders (36%) in the symptomatic group showed increased radioisotope uptake exceeding 2 standard deviations from the mean of the no tear group. This percentage was significantly higher when compared with the asymptomatic group (0%) (P < .01). Shoulders with a symptomatic rotator cuff tear showed higher radioisotope uptake on bone scintigraphy than those with an asymptomatic tear. The radioisotope uptake in shoulders with an asymptomatic tear was comparable with that in shoulders without a tear. Positive radioisotope uptake may be associated with pain in a subgroup of patients with rotator cuff tears.
Dynamics of translational friction in needle-tissue interaction during needle insertion.
Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R
2014-01-01
In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.
Divalent cations in tears, and their influence on tear film stability in humans and rabbits.
Wei, Xiaojia Eric; Markoulli, Maria; Millar, Thomas J; Willcox, Mark D P; Zhao, Zhenjun
2012-06-05
Reduced tear film stability is reported to contribute to dry eye. Rabbits are known to have a more stable tear film than humans. Thus, we sought to examine the tears of rabbits and humans for metal cations, and to test how they influence tear film stability. Tears were collected from 10 healthy humans and 6 rabbits. Tear osmolality was measured by vapor pressure osmometer, and metals analyzed using inductively coupled plasma (ICP) mass spectrometry or ICP atomic emission spectroscopy. The influence of divalent cations on tears was analyzed by measuring surface tension using the Langmuir trough in vitro, using different concentrations of cations in the subphase, and grading the tear break-up in rabbits in vivo after instillation of chelating agents. Rabbit tears had a higher osmolality compared to humans. Major metals did not differ between species; however, rabbits had higher levels of Mg(2+) (1.13 vs. 0.39 mM) and Ca(2+) (0.75 vs. 0.36 mM). In rabbit tears in vitro, diminishing divalent cations resulted in a decrease in the maximum surface pressure from 37 to 30 mN/m. In vivo, an increase in the amount of tear film that was broken-up was found. In contrast, when changing divalent cation concentrations in human tears, the maximum surface pressure remained at 26 mN/m. The normal osmolality of rabbit tears is significantly higher than that in humans. While divalent cations had little influence on human tears, they appear to have an important role in maintaining tear film stability in rabbits.
Increasing age and tear size reduce rotator cuff repair healing rate at 1 year.
Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J
2017-12-01
Background and purpose - There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods - Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results - The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation - Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor.
Budai-Szűcs, Mária; Horvát, Gabriella; Szilágyi, Barnabás Áron; Gyarmati, Benjámin; Szilágyi, András; Berkó, Szilvia; Szabó-Révész, Piroska; Sandri, Giuseppina; Bonferoni, Maria Cristina; Caramella, Carla; Soós, Judit; Facskó, Andrea; Csányi, Erzsébet
2016-01-01
Dry eye disease is a relatively common ocular problem, which causes eye discomfort and visual disorders leading to a decrease in the quality of life. The aim of this study was to find a possible excipient for eye drop formulations, which is able to stabilize the tear film. A cationic thiolated polyaspartamide polymer, poly[(N-mercaptoethylaspartamide)-co-(N-(N',N'-dimethylaminoethyl)aspartamide)] (ThioPASP-DME), was used as a potential vehicle. Besides satisfying the basic requirements, the chemical structure of ThioPASP-DME is similar to those of ocular mucins as it is a protein-like polymer bearing a considerable number of thiol groups. The solution of the polymer is therefore able to mimic the physiological properties of the mucins and it can interact with the mucus layer via disulphide bond formation. The resultant mucoadhesion provides a prolonged residence time and ensures protective effect for the corneal/conjunctival epithelium. ThioPASP-DME also has an antioxidant effect due to the presence of the thiol groups. The applicability of ThioPASP-DME as a potential excipient in eye drops was determined by means of ocular compatibility tests and through examinations of the interactions with the mucosal surface. The results indicate that ThioPASP-DME can serve as a potential eye drop excipient for the therapy of dry eye disease.
Induced videokeratography alterations in patients with excessive meibomian secretions.
Markomanolakis, Marinos M; Kymionis, George D; Aslanides, Ioannis M; Astyrakakis, Nikolaos; Pallikaris, Ioannis G
2005-01-01
To describe lipid-induced specific videokeratographic (VKG) corneal changes and subsequent resolution after eyelid washing. VKG was performed with C-Scan corneal topography. In all patients an excessive meibomian gland lipid secretion was found with or without coexistent chronic posterior blepharitis. After the initial VKG, a meticulous cleaning of the lids with a mild alkali shampoo (10% Johnson's baby shampoo in sterile water) was done, first by gently scrubbing the closed eyelid fissure with the solution to mobilize and emulsify any Meibomian gland secretions followed by cleaning of the upper and lower margins individually, using Q-tip applicators soaked in the detergent. Three patients with tear film lipid layer excess (TFLE), which correlated with the presence of a superior or central corneal steepening in VKG, were studied. In two of the subjects, careful lid washing reversed either completely or partially this VKG effect, whereas in the last patient the VKG changes after artificially increasing the tear film lipid content is described. Meibomian gland lipid secretions may induce mainly superior and occasionally central VKG corneal steepening that is not correlated with any slit-lamp pathologic findings. Computerized corneal topography can help detect such corneal abnormalities, and their reversibility may distinguish them from other pathologic conditions (such as contact lens-induced warpage, eccentric ablations, irregular astigmatism, superior keratoconus).
Shayani Rad, Maryam; Mohajeri, Seyed Ahmad
2017-03-01
Ciprofloxacin (Cipro) is an antibiotic, widely used in form of ophthalmic drops (0.3%) for the treatment of eye infections. In this study, vitamin E was used as a hydrophobic barrier to improve and prolong the amount and time of Cipro release from silicone-based soft contact lenses. Three different commercial contact lenses (Air Optix, Biofinity, and Acuvue Oasys) were soaked in vitamin E solutions (0.1 and 0.2 g/mL). The effect of vitamin E on Cipro loading amount and drug releasing profile was evaluated in artificial tear. Swelling properties and diameter changes of the lenses were also investigated in aqueous media in presence and absence of vitamin E. The data indicated that vitamin E, as a hydrophobic barrier, significantly decreased the water content of silicone-based soft contact lenses. After vitamin E loading, a 5% to 18% increase was observed in lens diameter in the hydrated state, whereas the lens diameter increased by 11% to 23% in the dry state. In all commercial lenses, vitamin E loading in a 0.2-g/mL solution caused a 27.94% to 37.08% increase in Cipro binding. The results indicated that applying vitamin E loading solutions, with 0.1 and 0.2 g/mL concentrations, could effectively enhance Cipro release time from 2 hr (in a pure non-vitamin E-loaded lens) to 14 to 17 and 30 to 33 days, respectively. These values showed an increase by a factor of 168 to 204 and 360 to 396 in Cipro release time after using vitamin E loading solutions with 0.1 and 0.2 g/mL concentrations, respectively, compared with pure non-vitamin E-loaded soft contact lenses. This study indicated that vitamin E acts as an effective hydrophobic barrier, in increasing the Cipro loading capacity of silicone-based contact lenses and prolonging the drug release into the artificial tear.
Paulsen, Friedrich; Langer, Gesa; Hoffmann, Werner; Berry, Monica
2004-05-01
The objective of this study was to determine whether the lacrimal gland synthesizes mucins and whether they are changed with age or in cases of dry eye. Expression of mucins in human lacrimal glands was monitored by reverse transcription-polymerase chain reaction analysis. Furthermore, the presence and distribution of MUC1, -2, -4, -5AC, -5B, -6 and -7 in epithelia of the human lacrimal gland and its excretory duct system were assessed with antisera to mucin peptide cores. Thirty normal tissues from cadavers of different ages were tested, plus four with dry eye treated with artificial tears. Expression studies detected mRNAs for mucins MUC1, -4, -5AC, -5B, -6 and -7; whereas the MUC2 message was absent. The message for MUC4 was present in all four cases of dry eye, but only in six out of the 30 normal glands from individuals who did not receive artificial tears. MUC6 mRNA was detected only in about half of the investigated samples. Immunohistochemistry revealed membrane-bound MUC1 at the apical surface of acinar cells, absence of MUC2, MUC5AC associated with goblet cells of excretory ducts, MUC5B and -7 in the cytoplasm of acinar cells, and MUC7 also in epithelial cells of excretory ducts. MUC4 mucin was detected only in those individuals in which message was identified. In dry eyes, MUC5AC and -5B were localized in the same acinar cells; whereas MUC2 and MUC6 were not detectable. Dot-blot analysis clearly revealed increased amounts of MUC4, -5AC, and -5B in the glands of elderly women who received treatment for dry eyes. These results confirm that the human lacrimal gland synthesizes a spectrum of mucins; part of them might be correlated with age. Copyright 2004 Springer-Verlag
Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A
2016-01-01
Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.
Hicks, C R; Chirila, T V; Dalton, P D; Clayton, A B; Vijayasekaran, S; Crawford, G J; Constable, I J
1996-08-01
To develop a prototype artificial cornea and evaluate it in the rabbit model. Hydrogel core-and-skirt keratoprostheses were made and were inserted as full-thickness implants covered with conjunctival flaps in the right eyes of eight rabbits. Peroperative complications related to inadequate mechanical strength led to failure in the early postoperative period in three animals, one was euthanased for an unrelated reason and the remaining four have been successful for up to 16 weeks' follow-up. Full-thickness implantation of an artificial cornea, analogous to penetrating keratoplasty, has been achieved in the rabbit model. Histological findings confirm that integration of the prosthesis with host tissue occurs. The main complications encountered in this preliminary series were related to inadequate strength of the sponge skirt of this prototype device. Work in our laboratories is now concentrated upon improving the mechanical qualities of the hydrogel skirt and on the enhancement of biointegration.
Takahashi, N; Sugaya, H; Matsuki, K; Miyauchi, H; Matsumoto, M; Tokai, M; Onishi, K; Hoshika, S; Ueda, Y
2017-06-01
The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. The mean CSA was 21.0 mm 2 (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm 2 (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm 2 (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p < 0.001). In the affected shoulders, there were significant differences between patients with more than a medium sized posterosuperior cuff tear and those with an antero-superior cuff tear. Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806-11. ©2017 The British Editorial Society of Bone & Joint Surgery.
Increasing age and tear size reduce rotator cuff repair healing rate at 1 year
Rashid, Mustafa S; Cooper, Cushla; Cook, Jonathan; Cooper, David; Dakin, Stephanie G; Snelling, Sarah; Carr, Andrew J
2017-01-01
Background and purpose — There is a need to understand the reasons why a high proportion of rotator cuff repairs fail to heal. Using data from a large randomized clinical trial, we evaluated age and tear size as risk factors for failure of rotator cuff repair. Patients and methods — Between 2007 and 2014, 65 surgeons from 47 hospitals in the National Health Service (NHS) recruited 447 patients with atraumatic rotator cuff tendon tears to the United Kingdom Rotator Cuff Trial (UKUFF) and 256 underwent rotator cuff repair. Cuff integrity was assessed by imaging in 217 patients, at 12 months post-operation. Logistic regression analysis was used to determine the influence of age and intra-operative tear size on healing. Hand dominance, sex, and previous steroid injections were controlled for. Results — The overall healing rate was 122/217 (56%) at 12 months. Healing rate decreased with increasing tear size (small tears 66%, medium tears 68%, large tears 47%, and massive tears 27% healed). The mean age of patients with a healed repair was 61 years compared with 64 years for those with a non-healed repair. Mean age increased with larger tear sizes (small tears 59 years, medium tears 62 years, large tears 64 years, and massive tears 66 years). Increasing age was an independent factor that negatively influenced healing, even after controlling for tear size. Only massive tears were an independent predictor of non-healing, after controlling for age. Interpretation — Although increasing age and larger tear size are both risks for failure of rotator cuff repair healing, age is the dominant risk factor. PMID:28880113
Potential Market for New Meniscus Repair Strategies: Evaluation of the MOON Cohort
Fetzer, Gary B.; Spindler, Kurt P.; Amendola, Annunziato; Andrish, Jack T.; Bergfeld, John A.; Dunn, Warren R.; Flanigan, David C.; Jones, Morgan; Kaeding, Christopher C.; Marx, Robert G.; Matava, Matthew J.; McCarty, Eric C.; Parker, Richard D.; Wolcott, Michelle; Vidal, Armando; Wolf, Brian R.; Wright, Rick W.
2013-01-01
Background An estimated 200,000 ACL reconstructions are performed each year in the United States. The presence of concomitant meniscus tears and subsequent treatment at the time of ACL reconstruction may determine long-term outcomes of these knees. The authors contend that a substantial number of these meniscal tears are treated in a fashion that reduces meniscal function and that new technologies are needed to treat meniscal tears in a fashion that preserves function. A large cohort of patients with meniscal tears is needed to demonstrate this need. The purpose of this study is to determine the incidence of meniscal tears, describe tear morphology, and selected treatment in the MOON prospective longitudinal cohort of ACL reconstruction. We also will demonstrate based on national statistics the large potential market that exists for future tissue engineering aimed at preserving meniscal function. Methods A multicenter cohort of 1014 patients undergoing ACL reconstruction between January 2002 and December 2003 were evaluated. All procedures were performed by nine fellowship trained sports medicine orthopaedic surgeons. Data on patient demographics, presence of a meniscus tear at time of ACL reconstruction, tear morphology, and meniscal treatment were collected prospectively. Meniscal tears were categorized into three potential tissue engineering treatment strategies: all-biologic repair, advanced repair, and scaffold replacement. Results 1014 ACL reconstructions were performed over the two year period. The median age at the time of surgery was 24 years. Thirty-six percent of the knees had medial meniscal tears and 44% of the knees had lateral meniscal tears. Longitudinal tears were the most common tear morphology. The most frequent treatment modality was partial meniscectomy (60%). Thirty percent of medial meniscal tears and 10% of lateral meniscal tears could be treated with all-biologic repair, 32% of medial meniscal tears and 28% of lateral meniscal tears could be treated with an advanced repair technique, and 35% of medial meniscal tears and 62% of lateral meniscal tears could be treated with scaffold replacement. Conclusions Although meniscal preservation is a generally accepted concept in the treatment of meniscal tears, the majority of tears in this young cohort undergoing ACL reconstruction were either not repairable types (radial) and/or in the avascular zone. Even with contemporary approaches to meniscal tear repair, we found significant limitations faced by the treating surgeon. The majority of tears in this population are currently treated by partial meniscectomy. The results of this cohort will hopefully, stimulate and focus future research and development of new tissue engineering strategies for a large potential market for meniscal function in an ACL reconstructed cohort. PMID:19634719
Groin Injuries (Athletic Pubalgia) and Return to Play.
Elattar, Osama; Choi, Ho-Rim; Dills, Vickie D; Busconi, Brian
2016-07-01
Groin pain is a common entity in athletes involved in sports that require acute cutting, pivoting, or kicking such as soccer and ice hockey. Athletic pubalgia is increasingly recognized as a common cause of chronic groin and adductor pain in athletes. It is considered an overuse injury predisposing to disruption of the rectus tendon insertion to the pubis and weakness of the posterior inguinal wall without a clinically detectable hernia. These patients often require surgical therapy after failure of nonoperative measures. A variety of surgical options have been used, and most patients improve and return to high-level competition. PubMed databases were searched to identify relevant scientific and review articles from January 1920 to January 2015 using the search terms groin pain, sports hernia, athletic pubalgia, adductor strain, osteitis pubis, stress fractures, femoroacetabular impingement, and labral tears. Clinical review. Level 4. Athletic pubalgia is an overuse injury involving a weakness in the rectus abdominis insertion or posterior inguinal wall of the lower abdomen caused by acute or repetitive injury of the structure. A variety of surgical options have been reported with successful outcomes, with high rates of return to the sport in the majority of cases. © 2016 The Author(s).
Application of Photosynthesis to Artificial Sight
2001-10-25
to people who suffer from age-related macular degeneration (AMD) or retinitis pigmentosa (RP), diseases that are the leading causes of blindness...related macular degeneration and retinitis pigmentosa . While this work is still in its infancy, it is clear that isolated Photosystem I reaction...insertion of purified Photosystem I (PSI) reaction centers or other photoactive agents into retinal cells where they will restore photoreceptor function
The prevalence of rotator cuff tears: is the contralateral shoulder at risk?
Liem, Dennis; Buschmann, Vera Elisa; Schmidt, Carolin; Gosheger, Georg; Vogler, Tim; Schulte, Tobias L; Balke, Maurice
2014-04-01
Rotator cuff tears are a common cause of pain and disability of the shoulder. Information on the prevalence and identification of potential risk factors could help in early detection of rotator cuff tears and improve treatment outcome. Patients treated for a symptomatic rotator cuff tear on one side have a higher prevalence of rotator cuff tears and decreased shoulder function on the contralateral side compared with an age- and sex-matched group of healthy individuals. Case control study; Level of evidence, 3. One group consisted of 55 patients who had been arthroscopically treated on one shoulder for rotator cuff tear (tear group). In this group, the nonoperated contralateral shoulder was examined. For comparison, the matching shoulder in a control group consisting of 55 subjectively healthy individuals matched by age (±1 year) and sex to the tear group was included. Diagnosis of a rotator cuff tear was made by ultrasound. Outcomes were measured using the Constant score. The prevalence of supraspinatus tears was significantly higher (P < .0001) in the tear group (67.3%) compared with the control group (11.0%). The Constant score for the activities of daily living subscale, however, was significantly lower (18.4) in the tear group compared with the control group (19.9; P = .012). No other subcategory score nor the overall score showed a significant difference. There was a significantly higher tear prevalence in the tear group of patients aged between 50 and 59 years (P < .001) and 60 and 69 years (P = .004). No tear was diagnosed in the control group in individuals younger than 60 years. Patients treated for partial and full-thickness rotator cuff tears have a significantly higher risk of having a tear on the contralateral side and have noticeable deficits in their shoulder function regarding activities of daily living even if the tear is otherwise asymptomatic.
Park, Do Young; Min, Byoung-Hyun; Choi, Byung Hyune; Kim, Young Jick; Kim, Mijin; Suh-Kim, Haeyoung; Kim, Joon Ho
2015-12-01
Fibrocartilage metaplasia in tendons and ligaments is an adaptation to compression as well as a pathological feature during degeneration. Medial meniscus posterior roots are unique ligaments that resist multidirectional forces, including compression. To characterize the degeneration of medial meniscus posterior root tears in osteoarthritic knees, with an emphasis on fibrocartilage and calcification. Cross-sectional study; Level of evidence, 3. Samples of medial meniscus posterior roots were harvested from cadaveric specimens and patients during knee replacement surgery and grouped as follows: normal reference, no tear, partial tear, and complete tear. Degeneration was analyzed with histology, immunohistochemistry, and real-time polymerase chain reaction. Uniaxial tensile tests were performed on specimens with and without fibrocartilage. Quantifiable data were statistically analyzed by the Kruskal-Wallis test with the Dunn comparison test. Thirty, 28, and 42 samples harvested from 99 patients were allocated into the no tear, partial tear, and complete tear groups, respectively. Mean modified Bonar tendinopathy scores for each group were 3.97, 9.31, and 14.15, respectively, showing a higher degree of degeneration associated with the extent of the tear (P < .05 for all groups). The characterization of root matrices revealed an increase in fibrocartilage according to the extent of the tear. Tear margins revealed fibrocartilage in 59.3% of partial tear samples and 76.2% of complete tear samples, with a distinctive cleavage-like shape. Root tears with a similar shape were induced within fibrocartilaginous areas during uniaxial tensile testing. Even in the no tear group, 56.7% of samples showed fibrocartilage in the anterior margin of the root, adjacent to the meniscus. An increased stained area of calcification and expression of the ectonucleotide pyrophosphatase/phosphodiesterase 1 gene were observed in the complete tear group compared with the no tear group (P < .0001 and P = .24, respectively). Fibrocartilage and calcification increased in medial meniscus posterior roots, associated with the degree of the tear. Both findings, which impair the ligament's resistance to tension, may play a pivotal role during the pathogenesis of degenerative meniscus root tears in osteoarthritic knees. Fibrocartilage and calcification may be useful as diagnostic markers as well as markers of degeneration, which may aid in determining the treatment modality in meniscus root tears. The presence of fibrocartilage in intact roots may suggest an impending tear in osteoarthritic knees. © 2015 The Author(s).
Dhasmana, Renu; Nagpal, Ramesh Chander
2016-01-01
Introduction Dry eye is one of the most common ocular diseases in this cyber era. Despite availability of multiple tests, no single test is accurate for the diagnosis of dry eye. Anterior segment optical coherence tomography is the recent tool which can be added in the armentarium of dry eye tests. Aim To evaluate tear meniscus with anterior segment optical coherence tomography and its correlation with other tear variables in normal healthy individuals. Materials and Methods In this prospective cross-sectional observational study, right eye of 203 consecutive patients were studied. All the patients were divided into three groups Group 1, 2 and 3 according to their age ≤20 years, 21-40 years and >40 years respectively. All patients underwent routine ophthalmologic examinations along with slit-lamp bio-microscopy for tear meniscus height measurement, tear film break up time, Schirmer’s I test (with anaesthesia) and optical coherence tomography imaging of inferior tear meniscus height. After focusing of the instrument with a Cross Line (CL) centered on lower tear meniscus at 6’0 clock of cornea, a 6 mm long scan was obtained. The tear meniscus height (μm) and tear meniscus area (mm2) were measured manually with help of callipers by joining upper corneo-meniscus junction to the lower lid-meniscus junction and tear meniscus height and area within the plotted line respectively and calculated by using the integrated analysis available in the custom software. Results There was significant decrease in the all tear variables with the increase in the age. According to age groups in group 1, the mean Schirmer’s (24.0±4.9)mm, tear film break up time (11.1±1.9) sec, tear meniscus height on slit lamp (600.2±167.3)mm were higher but decreased in group 2 (21.5±5.4,10.8±1.4, 597.5±186.3) and group 3 (19.8 ± 5.1, 10.2 ± 1.6, 485.6 ± 157.7) respectively. Schirmer’s test values and tear film break up time were similar in both sexes (p=0.1 and p= 0.9). Tear meniscus height on slit lamp and Optical coherence based tear meniscus area were similar in both sexes (p=0.5 and p=0.1). However, tear meniscus height on optical coherence tomography was significantly higher in females (p=0.04). Value of Schirmer’s and tear film break up time (r =0.2; p= 0.001) and Schirmer’s and tear meniscus height on slit lamp (r=0.6; p<0.001) had positive correlation. Tear meniscus height and tear meniscus area on optical coherence tomography had positive correlation (r =.9; p<0.001). Conclusion On optical coherence tomography tear meniscus height and area significantly correlated. Despite higher values of Schirmer’s, tear film break up time, Slit lamp based tear meniscus height in younger age group the tear meniscus height and tear meniscus area with optical coherence tomography were lower. PMID:27437253
TFOS DEWS II Tear Film Report.
Willcox, Mark D P; Argüeso, Pablo; Georgiev, Georgi A; Holopainen, Juha M; Laurie, Gordon W; Millar, Tom J; Papas, Eric B; Rolland, Jannick P; Schmidt, Tannin A; Stahl, Ulrike; Suarez, Tatiana; Subbaraman, Lakshman N; Uçakhan, Omür Ö; Jones, Lyndon
2017-07-01
The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership. Copyright © 2017 Elsevier Inc. All rights reserved.
The brilliant beauty of the eye: light reflex from the cornea and tear film.
Goto, Eiki
2006-12-01
Light reflex from the cornea and tear film as contributors to beautiful eyes ("eye sparkling") are reviewed. A systematic literature review was conducted using "Purkinje-Sanson image," "corneal light reflex," "corneal topography," "corneal wavefront aberration," and "tear interference image" as search terms. Articles on corneal surface regularity and stability and tear interferometry of the precorneal tear lipid layer were reviewed. PS-1 image, that is light reflex from the cornea and tear film, is widely used in practical ophthalmic examination. To achieve a brilliant beauty of the eye ("eye sparkling"), it is important that the tear film (aqueous layer) surface is smooth and stable with adequate tear volume and that the tear lipid layer is present in adequate thickness.
Patel, Roshni; Zhu, Meifang; Robertson, Danielle M
2018-06-01
The human corneal epithelium expresses both the insulin-like growth factor type 1 receptor (IGF-1R) and the IGF-1R/insulin receptor (INSR) hybrid. Despite the previous identification of IGF-1 in human tear fluid, little is known regarding the regulation of IGF-1 in tear fluid and its role in corneal epithelial homeostasis. In the present study, we investigated the impact of biological parameters on the concentration of human tear levels of IGF-1. Tear levels of IGF-1 were measured in 41 healthy, human volunteers without any reported symptoms of dry eye. All volunteers underwent standard biomicroscopic examination of the cornea and tear film. In a subgroup of volunteers, corneal staining with sodium fluorescein, tear film break up time and tear production using a Schirmer's test strip were measured to assess clinical signs of dry eye. Tears were collected from the inferior tear meniscus using glass microcapillary tubes and IGF-1 levels were measured using a solid phase sandwich ELISA. Tear levels of IGF-1 were highest in young adults and significantly decreased in older adults (P = 0.003). There were no differences in tear IGF-1 between males and females (P = 0.628). Tear IGF-1 levels were correlated with tear film break up time (R = 0.738) and tear production (R = 0.826). These data indicate that there is a progressive decline in tear IGF-1 due to aging that is associated with clinical signs of dry eye. This effect is likely due to age-related changes in the lacrimal gland. Copyright © 2018 Elsevier Ltd. All rights reserved.
Detection of endogenous cortisol in equine tears and blood at rest and after simulated stress.
Monk, Caroline S; Hart, Kelsey A; Berghaus, Roy D; Norton, Natalie A; Moore, Phillip A; Myrna, Kathern E
2014-07-01
To determine whether cortisol is present in equine tears at rest and during simulated stress and compare tear cortisol to serum free and total cortisol. Fourteen healthy adult horses were included. Paired tear total cortisol and serum total and free cortisol concentrations were measured with ELISA, chemiluminescent immunoassay, and ultrafiltration methodology, respectively, in 10 horses at rest once daily for five consecutive days. In an additional four horses, paired tear and serum samples were collected for cortisol measurement before and after adrenocorticotropic hormone (ACTH) stimulation (cosyntropin, 1 μg/kg IV). Cortisol was detectable in equine tears at rest. Following ACTH stimulation, tear cortisol increased significantly from baseline at 60-120 min (P ≤ 0.001). Serum total and free cortisol also increased significantly at 30-180 min after ACTH stimulation (P ≤ 0.001). Both serum and tear cortisol returned to baseline concentrations by 360 min. Changes in tear cortisol were similarly associated with changes in serum total and free cortisol, although high tear cortisol concentrations suggest a portion of tear cortisol may be protein-bound. Cortisol is present in equine tears and increases in concert with serum cortisol following ACTH stimulation. Further study is needed to determine whether endogenous cortisol in tears contributes to ocular pathology. © 2013 American College of Veterinary Ophthalmologists.
A comparison of MRI findings in patients with acute and chronic ACL tears.
Dimond, P M; Fadale, P D; Hulstyn, M J; Tung, G A; Greisberg, J
1998-01-01
This retrospective study compared the magnetic resonance imaging (MRI) findings in 87 patients with acute and chronic anterior cruciate ligament (ACL) tears. Sixty patients had acute tears and 27 had chronic tears. The appearance of the torn ligament was examined on MRI, and associated meniscal and osteochondral injuries were described. All findings were verified at arthroscopy. Acute ACL tears (MRI examination was performed within 6 weeks of injury) were typified by the presence of diffuse (58%) or focal (42%) increased signal within the ligament, whereas chronic ACL tears (MRI examination was performed more than 6 months after injury) usually appeared as either a fragmented ligament (44%) or an intact band of low signal with abnormal orientation (30%). Patients with chronic ACL tears had a higher prevalence of medial meniscal tears (78% versus 40%), articular chondromalacia, and an increased posterior cruciate bow ratio (0.47 versus 0.37) in association with chronic ACL tears. A bone bruise was seen in 68% of acute ACL tears but in no case of chronic ACL tear. On MRI, there are salient differences between acute and chronic ACL tears. Chronic ACL tears are associated with a greater prevalence of meniscal and osteochondral injuries. These findings may have implications for future treatment recommendations.
Koh, Shizuka; Tung, Cynthia; Aquavella, James; Yadav, Rahul; Zavislan, James; Yoon, Geunyoung
2010-07-01
PURPOSE. To investigate tear film dynamics using simultaneous measurements of ocular aberrations and lower tear meniscus. METHODS. Simultaneous measurements of wavefront aberration and lower tear meniscus were performed for 11 normal eyes and 7 eyes with short tear film break-up time (SBUT) dry eye, with a tear film break-up time shorter than 5 seconds, using a wavefront sensor and an anterior segment optical coherence tomography (OCT). During the measurement, the subjects were instructed to blink every 6 seconds for a total of 30 seconds. From the measured aberration, root mean square (RMS) wavefront error and volume modulation transfer function (vMTF) induced by changes in tear film dynamics were calculated for a 5-mm pupil. Lower tear meniscus height (TMH) and area (TMA) were estimated from the cross-sectional OCT images of lower tear meniscus. RESULTS. There was a positive correlation between RMS and tear meniscus dimensions and a negative correlation between vMTF and tear meniscus in both groups. There were moderate negative correlations between the postblink initial RMS change and baseline TMH (R = -0.61) and TMA (R = -0.54) in SBUT dry eyes that were stronger than in normal eyes (R = -0.37, R = -0.38). CONCLUSIONS. Tear meniscus dimensions increase with RMS over time, and tear quantity before blink has a significant role in maintaining initial optical integrity, especially in SBUT dry eye. Simultaneous measurement of optical quality and tear meniscus has the potential to improve understanding of tear stability in normal eyes and dry eyes.
Mass Spectrometric Identification of Phospholipids in Human Tears and Tear Lipocalin
Dean, Austin W.; Glasgow, Ben J.
2012-01-01
Purpose. The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Methods. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Results. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490–540) accounted for about 80% of the total integrated ion count. The [M+H]+ compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin–bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Conclusions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin. PMID:22395887
Mass spectrometric identification of phospholipids in human tears and tear lipocalin.
Dean, Austin W; Glasgow, Ben J
2012-04-02
The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490-540) accounted for about 80% of the total integrated ion count. The [M+H](+) compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin-bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin.
Guyette, Nicole; Williams, Larezia; Tran, My-Tho; Than, Tammy; Bradley, John; Kehinde, Lucy; Edwards, Clara; Beasley, Mark; Fullard, Roderick
2013-05-01
Low tear volume limits the use of nonstimulated (NS) microcapillary tear collection in aqueous-deficient (AD) patients. Adding a small amount of "washout" fluid to the eye prior to tear collection is a potentially viable alternative method for abundant proteins, but is relatively untested for low-abundance biomarkers. This study determined the feasibility of the washout (WO) method as an NS alternative for low-abundance biomarkers. NS and WO biomarker profiles were compared between AD patients and non-AD controls to determine if the two methods identify the same intergroup differences. Matching NS and WO tears were collected from 48 patients by micropipette, the WO sample after instillation of 10 μL saline. Tear cytokine levels were measured by 27-Plex Bio-Rad assay. Bland-Altman analyses for each biomarker determined the agreement between tear sample types. Patients were grouped as AD or non-AD based on Schirmer score to determine if NS profile between-group differences were preserved in WO tears. Bland-Altman plots showed good biomarker level agreement between NS and WO tears for most cytokines. Five biomarkers, among those most often cited as differing in AD dry eye, differed significantly between non-AD and AD groups in both tear types. Additional biomarker differences were seen in NS tears only. The WO tear collection method is a viable alternative to NS tears for many low-abundance biomarkers and is able to replicate major NS tear differences between dry eye groups. More subtle intergroup differences are lost in WO samples because of reduced statistical power.
Non-contrast magnetic resonance imaging for diagnosing shoulder injuries.
Arnold, Heino
2012-12-01
To compare preoperative non-contrast magnetic resonance imaging (MRI) with arthroscopy findings in diagnosing labral and rotator cuff tears. 86 men and 60 women aged 21 to 70 (mean, 52) years underwent non-contrast MRI before arthroscopic operations on the glenohumeral joint. Slices were made in a transverse, parasagittal, and paracoronar orientation. The sequences used were T2- and proton-weighted for paracoronar imaging, T1- and T2-weighted for transverse and parasagittal imaging, and T2-weigthed sequences with fat suppression and short tau inversion recovery sequences. MRI was evaluated with the surgeon to eliminate interobserver bias. Arthroscopic surgery was performed by a single surgeon. If a labral or rotator cuff tear was found, surgery was performed using corkscrew anchors. For full thickness rotator cuff tears, MRI and arthroscopy detected them in 76 and 82 patients, respectively. One such tear found by MRI could not be confirmed by arthroscopy. MRI missed 4 subscapularis and 3 supraspinatus tears. The sensitivity and specificity of MRI in diagnosing full thickness rotator cuff tears were 0.90 and 0.91, respectively. For labral tears, MRI and arthroscopy detected them in 16 and 31 patients, respectively. One anterior labral tear detected by MRI could not be verified by arthroscopy. All 16 labral tears detected by MRI were Bankart type-I tears (of the anterior glenoid) except for one superior labral tear from anterior to posterior (SLAP tear). All 13 SLAP tears (10 type 2 and 3 type 3) except for one could be found by arthroscopy only. The sensitivity and specificity of MRI in diagnosing labral tears were 0.52 and 0.89, respectively. Non-contrast MRI is reliable only for diagnosing full thickness rotator cuff tears and anterior labral tears. Direct or indirect contrast enhancement is recommended for more differentiation. Special scan orientation is necessary for SLAP tears.
Tear-Film Evaporation Rate from Simultaneous Ocular-Surface Temperature and Tear-Breakup Area.
Dursch, Thomas J; Li, Wing; Taraz, Baseem; Lin, Meng C; Radke, Clayton J
2018-01-01
A corneal heat-transfer model is presented to quantify simultaneous measurements of fluorescein tear-breakup area (TBA) and ocular-surface temperature (OST). By accounting for disruption of the tear-film lipid layer (TFLL), we report evaporation rates through lipid-covered tear. The modified heat-transfer model provides new insights into evaporative dry eye. A quantitative analysis is presented to assess human aqueous tear evaporation rate (TER) through intact TFLLs from simultaneous in vivo measurement of time-dependent infrared OST and fluorescein TBA. We interpret simultaneous OST and TBA measurements using an extended heat-transfer model. We hypothesize that TBAs are ineffectively insulated by the TFLL and therefore exhibit higher TER than does that for a well-insulting TFLL-covered tear. As time proceeds, TBAs increase in number and size, thereby increasing the cornea area-averaged TER and decreasing OST. Tear-breakup areas were assessed from image analysis of fluorescein tear-film-breakup video recordings and are included in the heat-transfer description of OST. Model-predicted OSTs agree well with clinical experiments. Percent reductions in TER of lipid-covered tear range from 50 to 95% of that for pure water, in good agreement with literature. The physical picture of noninsulating or ruptured TFLL spots followed by enhanced evaporation from underlying cooler tear-film ruptures is consistent with the evaporative-driven mechanism for local tear rupture. A quantitative analysis is presented of in vivo TER from simultaneous clinical measurement of transient OST and TBA. The new heat-transfer model accounts for increased TER through expanding TBAs. Tear evaporation rate varies strongly across the cornea because lipid is effectively missing over tear-rupture troughs. The result is local faster evaporation compared with nonruptured, thick lipid-covered tear. Evaporative-driven tear-film ruptures deepen to a thickness where fluorescein quenching commences and local salinity rises to uncomfortable levels. Mitigation of tear-film rupture may therefore reduce dry eye-related symptoms.
Duchman, Kyle R.; Westermann, Robert W.; Spindler, Kurt P.; Reinke, Emily K.; Huston, Laura J.; Amendola, Annunziato; Wolf, Brian R.
2016-01-01
Background The management of meniscus tears identified at the time of primary ACL reconstruction is highly variable and includes repair, meniscectomy, and non-treatment. Hypothesis/Purpose The purpose of this study is to determine the reoperation rate for meniscus tears left untreated at the time of ACL reconstruction with minimum follow-up of 6 years. We hypothesize that small, peripheral tears identified at the time of ACL reconstruction managed with “no treatment” will have successful clinical outcomes. Study Design Retrospective study of a prospective cohort; Level of Evidence, 3 Methods Patients with meniscus tears left untreated at the time of primary ACL reconstruction were identified from a multicenter study group with minimum 6-year follow-up. Patient, tear, and reoperation data were obtained for analysis. Need for reoperation was used as the primary endpoint, with analysis performed to determine patient and tear characteristics associated with reoperation. Results There were 194 patients with 208 meniscus tears (71 medial; 137 lateral) left in situ without treatment with complete follow-up for analysis. Of these, 97.8% of lateral and 94.4% of medial untreated tears required no reoperation. Sixteen tears (7.7%) left in situ without treatment underwent subsequent reoperation: 9 tears (4.3%) underwent reoperation in the setting of revision ACL reconstruction and 7 tears (3.4%) underwent reoperation for isolated meniscus pathology. Patient age was significantly lower in patients requiring reoperation, while tears measuring ≥ 10 mm more frequently required reoperation. Conclusions Lateral and medial meniscus tears left in situ at the time of ACL reconstruction did not require reoperation at minimum 6-year follow-up for 97.8% and 94.4% of tears, respectively. These findings reemphasize the low reoperation rate following non-treatment of small, peripheral lateral meniscus tears while noting less predictable results for medial meniscus tears left without treatment. PMID:26430058
Posterior meniscus root tears: associated pathologies to assist as diagnostic tools.
Matheny, Lauren M; Ockuly, Andrew C; Steadman, J Richard; LaPrade, Robert F
2015-10-01
The purpose of this study was to investigate associated pathologies identified at arthroscopy in patients with meniscus root tears. This study was Institutional Review Board approved. All patients who underwent arthroscopic knee surgery where a complete meniscus root tear was identified were included in this study. Concurrent ligament tears and articular cartilage changes ≥Outerbridge grade 2 were recorded and stored in a data registry. Fifty patients (28 males, 22 females) [mean age = 36.5 years (range 17.1-68.1 years)] who were diagnosed with a medial or lateral meniscus root tear at arthroscopy were included in this study out of 673 arthroscopic surgeries (prevalence 7.4 %). Twenty-three (46 %) patients had a medial meniscus root tear, 26 (52 %) patients had a lateral meniscus root tear and one (2 %) patient had both. Thirty-four per cent of patients (n = 17) underwent partial meniscectomy, while 60 % (n = 31) underwent suture repair. During arthroscopy, 60 % (n = 30) of patients were diagnosed with an anterior cruciate ligament (ACL) tear. Patients with lateral meniscus root tears were 10.3 times (95 % CI 2.6-42.5) more likely to have ACL tears than patients with medial meniscus root tears (p = 0.012). Patients who had medial meniscus root tears were 5.8 times (95 % CI 1.6-20.5) more likely to have chondral defects than patients who had lateral meniscus root tears (p = 0.044). In this study, patients' preoperative functional scores and activity levels were low. Patients with lateral meniscal root tears were more likely to have an ACL tear. Patients with medial meniscal root tears were more likely to have an knee articular cartilage defect with an Outerbridge grade 2 or higher chondral defect. This study confirms the importance of comprehensive assessment of concurrent injuries to properly diagnose meniscus root tears. IV.
Duchman, Kyle R; Westermann, Robert W; Spindler, Kurt P; Reinke, Emily K; Huston, Laura J; Amendola, Annunziato; Wolf, Brian R
2015-11-01
The management of meniscus tears identified at the time of primary anterior cruciate ligament (ACL) reconstruction is highly variable and includes repair, meniscectomy, and nontreatment. The purpose of this study was to determine the reoperation rate for meniscus tears left untreated at the time of ACL reconstruction with a minimum follow-up of 6 years. The hypothesis was that small peripheral tears identified at the time of ACL reconstruction managed with "no treatment" would have successful clinical outcomes. Cohort study; Level of evidence, 3. Patients with meniscus tears left untreated at the time of primary ACL reconstruction were identified from a multicenter study group with a minimum 6-year follow-up. Patient, tear, and reoperation data were obtained for analysis. The need for reoperation was used as the primary endpoint, with analysis performed to determine patient and tear characteristics associated with reoperation. There were 194 patients with 208 meniscus tears (71 medial, 137 lateral) left in situ without treatment with a complete follow-up for analysis. Of these, 97.8% of lateral and 94.4% of medial untreated tears required no reoperation. Sixteen tears (7.7%) left in situ without treatment underwent subsequent reoperation: 9 tears (4.3%) underwent reoperation in the setting of revision ACL reconstruction, and 7 tears (3.4%) underwent reoperation for an isolated meniscus injury. The patient age was significantly lower in patients requiring reoperation, while tears measuring ≥10 mm more frequently required reoperation. Lateral and medial meniscus tears left in situ at the time of ACL reconstruction did not require reoperation at a minimum 6-year follow-up for 97.8% and 94.4% of tears, respectively. These findings re-emphasize the low reoperation rate after the nontreatment of small, peripheral lateral meniscus tears while noting less predictable results for medial meniscus tears left without treatment. © 2015 The Author(s).
Rat supraspinatus muscle atrophy after tendon detachment.
Barton, Elisabeth R; Gimbel, Jonathan A; Williams, Gerald R; Soslowsky, Louis J
2005-03-01
Rotator cuff tears are one of the most common tendon disorders found in the healthy population. Tendon tears not only affect the biomechanical properties of the tendon, but can also lead to debilitation of the muscles attached to the damaged tendons. The changes that occur in the muscle after tendon detachment are not well understood. A rat rotator cuff model was utilized to determine the time course of changes that occur in the supraspinatus muscle after tendon detachment. It was hypothesized that the lack of load on the supraspinatus muscle would cause a significant decrease in muscle mass and a conversion of muscle fiber properties toward those of fast fiber types. Tendons were detached at the insertion on the humerus without repair. Muscle mass, morphology and fiber properties were measured at one, two, four, eight, and 16 weeks after detachment. Tendon detachment resulted in a rapid loss of muscle mass, an increase in the proportion of fast muscle fibers, and an increase in the fibrotic content of the muscle bed, concomitant with the appearance of adhesions of the tendon to surrounding surfaces. At 16 weeks post-detachment, muscle mass and the fiber properties in the deep muscle layers returned to normal levels. However, the fiber shifts observed in the superficial layers persisted throughout the experiment. These results suggest that load returned to the muscle via adhesions to surrounding surfaces, which may be sufficient to reverse changes in muscle mass.
Park, In-Seop; Kim, Sung-Jae
2006-08-01
We introduce a suture technique to repair a peripheral tear near the posterior tibial attachment of the posterior horn. A suture hook was inserted through the posteromedial portal, and the peripheral capsular rim was penetrated from superior to inferior by the sharp hook. Both relay limbs were brought out through the posteromedial portal. The outer limb of the superior peripheral capsular rim was identified with a hemostat. An 18-gauge spinal needle loaded with a No. 0 polydioxanone suture (PDS) was introduced into the joint from the anteromedial portal; it was passed through the joint space until it penetrated the inner torn meniscus. The PDS suture loaded within the needle was pushed into the joint and picked up through the posteromedial portal. The needle was pulled out of the torn meniscus and readvanced over it while the suture was kept loaded. The other limb of the suture from the tip of the spinal needle was retrieved through the posteromedial portal. The initial PDS suture limb was hooked to the shuttle-relay system; it then was passed through the inner torn meniscus and the peripheral capsular rim. The suture limb exiting from the peripheral capsular rim was used as a post and was joined to the other suture limb to form a sliding knot.
de la Fuente, C; Carreño-Zillmann, G; Marambio, H; Henríquez, H
2016-01-01
To compare the mechanical failure of the Dresden technique for Achilles tendon repair with the double modified Kessler technique controlled repair technique. The maximum resistance of the two repair techniques are also compared. A total of 30 Achilles tendon ruptures in bovine specimens were repaired with an Ethibond(®) suture to 4.5cm from the calcaneal insertion. Each rupture was randomly distributed into one of two surgical groups. After repair, each specimen was subjected to a maximum traction test. The mechanical failure (tendon, suture, or knot) rates (proportions) were compared using the exact Fisher test (α=.05), and the maximum resistances using the Student t test (α=.05). There was a difference in the proportions of mechanical failures, with the most frequent being a tendon tear in the Dresden technique, and a rupture of the suture in the Kessler technique. The repair using the Dresden technique performed in the open mode, compared to the Kessler technique, has a more suitable mechanical design for the repair of middle third Achilles tendon ruptures on developing a higher tensile resistance in 58.7%. However, its most common mechanical failure was a tendon tear, which due to inappropriate loads could lead to lengthening of the Achilles tendon. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Tan, Mingsheng; Stone, Douglas R; Triana, Joseph C; Almagri, Abdulgader F; Fiksel, Gennady; Ding, Weixing; Sarff, John S; McCollam, Karsten J; Li, Hong; Liu, Wandong
2017-02-01
A 40-channel capacitive probe has been developed to measure the electrostatic fluctuations associated with the tearing modes deep into Madison Symmetric Torus (MST) reversed field pinch plasma. The capacitive probe measures the ac component of the plasma potential via the voltage induced on stainless steel electrodes capacitively coupled with the plasma through a thin annular layer of boron nitride (BN) dielectric (also serves as the particle shield). When bombarded by the plasma electrons, BN provides a sufficiently large secondary electron emission for the induced voltage to be very close to the plasma potential. The probe consists of four stalks each with ten cylindrical capacitors that are radially separated by 1.5 cm. The four stalks are arranged on a 1.3 cm square grid so that at each radial position, there are four electrodes forming a square grid. Every two adjacent radial sets of four electrodes form a cube. The fluctuating electric field can be calculated by the gradient of the plasma potential fluctuations at the eight corners of the cube. The probe can be inserted up to 15 cm (r/a = 0.7) into the plasma. The capacitive probe has a frequency bandwidth from 13 Hz to 100 kHz, amplifier-circuit limit, sufficient for studying the tearing modes (5-30 kHz) in the MST reversed-field pinch.
A new surgical approach for punctal occlusion using fibrous tissue from under the lacrimal caruncle
Yokoi, Norihiko; Komuro, Aoi; Sotozono, Chie; Kinoshita, Shigeru
2018-01-01
Purpose Surgical punctal occlusion is indispensable for the treatment of severe dry eye in cases where punctal-plug insertion is not applicable due to an enlarged or deformed punctum. However, permanent punctal occlusion is difficult in some cases. In our aim to establish a more reliable punctal occlusion, we have devised a new surgical approach for punctal occlusion. Patients and methods This study involved 20 puncta of 12 eyes of 12 patients (1 male and 11 females; mean age: 65.2 years) with severe aqueous-tear-deficient dry eye. A new surgical procedure for punctal occlusion using fibrous tissue from under the lacrimal caruncle into the diathermy-induced deepithelialized canaliculus as supporting tissue for punctal closure was performed. In all patients, the assessment of eye symptoms, as well as the condition of punctal occlusion by slit-lamp biomicroscopy, tear volume (tear-meniscus radius [TMR] measurement by meniscometry), the condition of precorneal tear film (graded by interferometry [IG]), measurement of fluorescein breakup time (FBUT), and scoring of ocular surface staining (fluorescein score of area [FSA] and density [FSD], and lissamine green score [LGS]) were performed, and the preoperative and 6-month-postoperative values were compared. Results In regard to the postoperative improvement of symptoms, 11 patients showed remarkable improvement, 1 patient showed improvement, and no reopening of the closed punctum was found in any patient. Test values were all significantly improved post surgery (all: P<0.05) as compared to those prior to surgery (respective values [mean ± SD], and the pre- and postoperative P-values were: TMR (mm) [0.18±0.08; 0.56±0.28, P=0.002], IG [4.3±0.9; 2.7±0.8, P=0.009], FBUT [0.4±0.6; 4.1±2.9, P=0.004], FSA [1.6±0.7; 0.7±0.9, P=0.03], FSD [2.7±0.7; 0.6±0.7, P=0.003], and LGS [5.1±2.7; 1.1±2.1, P=0.005]). Moreover, no postoperative complications were observed. Conclusion The findings of this study showed that our novel surgical procedure for punctal occlusion is highly successful and that it results in improved and more complete punctal occlusion. PMID:29563770
Kojima, Takashi; Matsumoto, Yukihiro; Ibrahim, Osama M A; Wakamatsu, Tais Hitomi; Uchino, Miki; Fukagawa, Kazumi; Ogawa, Junko; Dogru, Murat; Negishi, Kazuno; Tsubota, Kazuo
2011-11-11
To prospectively evaluate the effect of controlled adverse chamber environment (CACE) exposure on tear function, including tear osmolarity, in subjects wearing narafilcon A versus those wearing etafilcon A soft contact lens (SCL). Thirty-one healthy subjects with no history of contact lens wear (13 women, 18 men; average age, 30.5 ± 6.5 years) were randomly divided into age- and sex-matched groups (15 subjects wearing narafilcon A SCL; 16 subjects wearing etafilcon A SCL) and entered a CACE for 20 minutes. All subjects underwent tear osmolarity, tear evaporation rate, strip meniscometry, tear film breakup time, fluorescein vital staining, and functional visual acuity measurement before and after exposure to the controlled adverse chamber. The mean blink rate increased with significant deteriorations in the mean symptom VAS scores, mean tear osmolarity, tear evaporation rate, strip meniscometry score, and tear stability with CACE exposure along with a decrease in visual maintenance ratio in functional visual acuity testing in etafilcon A wearers. The mean symptom VAS scores, mean tear evaporation rate, tear stability, blink rates, and visual maintenance ratios did not change significantly in narafilcon A wearers after CACE exposure. This study suggested marked tear instability, higher tear osmolarity, and increased tear evaporation with marked dry eye and visual symptomatology in nonadapted hydrogel SCL wearers, suggesting that silicone hydrogel SCLs may be suitable for persons who live and work in cool, low-humidity, and windy environments, as tested in this study.
Tear analysis in contact lens wearers.
Farris, R L
1985-01-01
Tear analysis in contact lens wearers was compared with tear analysis in aphakics without contact lens wear and normal phakic patients. Subjects were divided into five groups: group 1, aphakic without contact lens; group 2, phakic with daily-wear hard contact lens; group 3, phakic with daily-wear soft contact lens; group 4, phakic with extended-wear soft contact lens; and group 5, aphakic with extended-wear soft contact lens. The experimental groups were compared with age- and sex-matched control groups for statistical analysis of tear variables by means of the Student's t-test. The variables measured were tear osmolarity, tear albumin, and lysozyme and lactoferrin concentrations in basal and reflex tears. Highly significant elevations of tear osmolarity were found in aphakic subjects without contact lenses. Less significant differences in tear osmolarity were found in phakic subjects with hard daily-wear lenses or with extended-wear soft lenses. Tear albumin, lysozyme, and lactoferrin in basal and reflex tears were not significantly different in the different groups of contact lens wearers or in the group of aphakic subjects without contact lenses compared with their control groups. Individual variations in tear albumin, lysozyme, and lactoferrin appeared to be responsible for the inability to demonstrate significant differences in tear composition in association with the wearing of different types of contact lenses. Older and aphakic patients demonstrated a tendency to have increased concentrations of proteins in the tears compared with younger, phakic contact lens wearers and normal controls without contact lenses. PMID:3914131
Behavioral and neural responses to infant and adult tears: The impact of maternal love withdrawal.
Riem, Madelon M E; van IJzendoorn, Marinus H; De Carli, Pietro; Vingerhoets, Ad J J M; Bakermans-Kranenburg, Marian J
2017-09-01
The current study examined behavioral and neural responses to infant and adult tears, taking into account childhood experiences with parental love-withdrawal. With functional MRI (fMRI), we measured neural reactivity to pictures of infants and adults with and without tears on their faces in nulliparous women with varying childhood experiences of maternal use of love withdrawal. Behavioral responses to infant and adult tears were measured with an approach-avoidance task. We found that individuals with experiences of love withdrawal showed less amygdala and insula reactivity to adult tears, but love withdrawal did not affect amygdala and insula reactivity to infant tears. During the approach-avoidance task, individuals responded faster to adult tears in the approach condition compared with the avoidance condition, indicating that adult tears facilitate approach behavior. Individuals responded faster to infant tears than to adult tears, regardless of approach or avoidance condition. Our findings suggest that infant tears are highly salient and may, therefore, overrule the effects of contextual and personal characteristics that influence the perception of adult crying. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
[Rotator cuff tear athropathy prevalence].
Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S
2017-01-01
Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.
Choi, Chul-Jun; Choi, Yun-Jin; Song, In-Bum; Choi, Chong-Hyuk
2011-06-01
The clinical and radiologic features of radial tears of the medial meniscus posterior horn were compared with those of horizontal tears. From January 2007 to December 2008, 387 consecutive cases of medial meniscal tears were treated arthroscopically. Among these, 91 were radial tears in the medial meniscus posterior horn, and 95 were horizontal tears in the posterior segment of the medial meniscus. The patients' data (age, gender, duration of symptom, body mass index, and injury history), radiographic findings (Kellgren and Lawrence score, posterior tibial slope, and femorotibial angle), and chondral lesions were recorded. The patient factors of age, gender, and body mass index were related to radial tears of the medial meniscus posterior horn. Radial tears were significantly correlated with Kellgren and Lawrence score, varus alignment, posterior tibial slope, and severity of the chondral lesion. Radial tears of the medial meniscus posterior horn are a unique clinical entity that are associated with older age, females and obesity, and are strongly associated with an increased incidence and severity of cartilage degeneration compared to horizontal tears.
The Coracohumeral Distance in Shoulders With Traumatic and Degenerative Subscapularis Tendon Tears.
Balke, Maurice; Banerjee, Marc; Greshake, Oliver; Hoeher, Juergen; Bouillon, Bertil; Liem, Dennis
2016-01-01
A reduced coracohumeral distance (CHD) is thought to be responsible for subcoracoid impingement. This only accounts for degenerative tendon tears. In traumatic tears, the subcoracoid space should be normal. The CHD in patients with traumatic subscapularis tendon tears is larger than that in patients with degenerative tears and does not differ from patients with an intact subscapularis tendon. Cohort study; Level of evidence, 3. A total of 83 patients with arthroscopically certified subscapularis tendon tears were included in the study. Forty-four patients had degenerative causes (group 1), and 39 had traumatic causes (group 2). The control group consisted of 20 patients with traumatic supraspinatus tendon tears and arthroscopically proven, intact subscapularis tendons (group 3). On preoperative axial magnetic resonance imaging, the distance between the CHD was measured, and the values of the 3 groups were compared using the t test. The mean (±SD) CHD in patients with degenerative subscapularis tendon tears was 8.6 ± 2.0 mm (range, 4.0-13.2 mm) and was significantly (P = .0003) smaller than that in patients with traumatic tears (10.2 ± 2.0 mm; range, 6.6-16.2 mm) or controls (10.4 ± 1.8 mm; range, 6.8-14.0 mm). The CHD of controls and patients with traumatic tears did not differ significantly (P = .7875). A CHD of less than 6 mm only occurred in patients with degenerative subscapularis tendon tears. The hypothesis that the CHD in patients with degenerative subscapularis tendon tears is significantly smaller than that in patients with traumatic tears or intact subscapularis tendons was confirmed. The CHD in patients with traumatic tears does not differ from that in controls. A CHD of less than 6 mm only occurs in patients with degenerative subscapularis tendon tears. © 2015 The Author(s).
Sanada, Hiromi; Nakagami, Gojiro; Koyano, Yuiko; Iizaka, Shinji; Sugama, Junko
2015-08-01
There is a lack of data from cohort studies for the incidence of skin tears among an elderly population in an Asian country. We estimated the cumulative incidence of skin tear, and identify its risk factor. The present prospective cohort study was carried out at a long-term medical facility in Japan. Participants included patients (n = 368) aged 65 years or older receiving hospital care. The 3-month cumulative incidence of skin tears was estimated by identifying them using direct inspection of the extremities. In order to find the risk factors for the skin tear incidence, odds ratios and their 95% confidence intervals of skin tear development in association with the factors were estimated using logistic regression analyses. A total of 14 patients developed skin tears, and their cumulative incidence was 3.8%. No patients with skin tears developed multiple wounds on their extremities. Half of the skin tears occurred on the outside of the right forearm, and just three skin tears were found in the lower legs. Multiple logistic analyses showed that pre-existing skin tears (odds ratio 15.42, 95% confidence interval 3.53-67.43, P < 0.001) and a 6-point decrease in the total score of the Braden Scale (odds ratio 0.10, 95% confidence interval 0.01-0.83, P < 0.033) were significantly associated with skin tear development. Patients with pre-existing skin tears and a low score of the Braden Scale have a higher risk of skin tear development during 3 months. These factors could be used to identify patients requiring prevention care for skin tears. © 2014 Japan Geriatrics Society.
Amato, Massimo; Pantaleo, Giuseppe; Abtellatif, Dina; Blasi, Andrea; Gagliani, Massimo; Iandolo, Alfredo
2018-01-01
The aim of this study is to evaluate in vitro , using artificial lateral canals, the rate of dissolution of the pulp tissue through different protocols of canal irrigation. One hundred artificial canals provided with lateral canals have been used. Each lateral canal was filled with pulp tissue and calibrated to 0.002 mg. All canals were irrigated using five different protocols. Five groups have been used for the experiment: Group A, distilled water (control); Group B, preheated NaOCl; Group C, NaOCl heated inside the canal; Group D, NaOCl ultrasonically activated; and Group E, NaOCl heated inside the canal with ultrasonic activation. All samples were weighed through professional microbalance in three different phases: before insertion of the pulp tissue into the lateral canal, after insertion of the pulp tissue and, finally, after different protocols of irrigation. A statistical analysis with Kruskal-Wallis test and Mann-Whitney test was performed. The partial dissolution of the pulp tissue inside the artificial lateral canal occurs only using the protocol with NaOCl heated inside the canal with ultrasonic activation. Other irrigation protocols are not able to dissolve the pulp tissue. The main objective of endodontic therapy is the removal of damaged tissues and bacteria. Modern literature highlights that it is impossible to remove all the pulp tissues and bacteria from the whole endodontic space. Hence, to achieve excellence and get positive results in the short and long term, it is necessary to use techniques and technologies that may increase the degree of root canal detersion.
Yatabe, Tomoaki; Nakamura, Ryu; Kitagawa, Hiroyuki; Munekage, Masaya; Hanazaki, Kazuhiro
2016-03-01
A 57-year-old woman was diagnosed with type I glycogen storage disease in her twenties. She had undergone hepatectomy under general anesthesia with epidural anesthesia. Fifty minutes after the induction of anesthesia, a 20-gauge venous catheter was inserted in the patient's right hand, and an artificial pancreas (STG-55, Nikkiso Co., Tokyo, Japan) was connected for continuous glucose monitoring and automatic glucose control. Insulin was infused when the blood glucose level reached 120 mg/dL or higher, and glucose was infused when the level fell to 100 mg/dL or lower. After the Pringle maneuver, the blood glucose level increased, and insulin was administered automatically via an artificial pancreas. Hypoglycemia did not occur during the operation. After total parenteral nutrition was started in the intensive care unit (ICU), the blood glucose level increased, and the artificial pancreas controlled the blood glucose level through automatic insulin administration. Thirty-four hours after admission to the ICU, the artificial pancreas was removed because the blood sampling failed. After the removal of the artificial pancreas, blood glucose level was measured every 2 h until extubation. During the ICU stay, hypoglycemia never occurred, with the average blood glucose level being 144 mg/dL. In conclusion, the use of an artificial pancreas for perioperative blood glucose management in a patient with glycogen storage disease had the beneficial effect of enabling the management of blood glucose levels without hypoglycemia.
A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair.
Smith, Christopher D; Alexander, Susan; Hill, Adam M; Huijsmans, Pol E; Bull, Anthony M J; Amis, Andrew A; De Beer, Joe F; Wallace, Andrew L
2006-11-01
The optimal method for arthroscopic rotator cuff repair is not yet known. The hypothesis of the present study was that a double-row repair would demonstrate superior static and cyclic mechanical behavior when compared with a single-row repair. The specific aims were to measure gap formation at the bone-tendon interface under static creep loading and the ultimate strength and mode of failure of both methods of repair under cyclic loading. A standardized tear of the supraspinatus tendon was created in sixteen fresh cadaveric shoulders. Arthroscopic rotator cuff repairs were performed with use of either a double-row technique (eight specimens) or a single-row technique (eight specimens) with nonabsorbable sutures that were double-loaded on a titanium suture anchor. The repairs were loaded statically for one hour, and the gap formation was measured. Cyclic loading to failure was then performed. Gap formation during static loading was significantly greater in the single-row group than in the double-row group (mean and standard deviation, 5.0 +/- 1.2 mm compared with 3.8 +/- 1.4 mm; p < 0.05). Under cyclic loading, the double-row repairs failed at a mean of 320 +/- 96.9 N whereas the single-row repairs failed at a mean of 224 +/- 147.9 N (p = 0.058). Three single-row repairs and three double-row repairs failed as a result of suture cut-through. Four single-row repairs and one double-row repair failed as a result of anchor or suture failure. The remaining five repairs did not fail, and a midsubstance tear of the tendon occurred. Although more technically demanding, the double-row technique demonstrates superior resistance to gap formation under static loading as compared with the single-row technique. A double-row reconstruction of the supraspinatus tendon insertion may provide a more reliable construct than a single-row repair and could be used as an alternative to open reconstruction for the treatment of isolated tears.
Medialized repair for retracted rotator cuff tears.
Kim, Young-Kyu; Jung, Kyu-Hak; Won, Jun-Sung; Cho, Seung-Hyun
2017-08-01
The purpose of this study was to evaluate the functional outcomes of medialized rotator cuff repair and the continuity of repaired tendon in chronic retracted rotator cuff tears. Thirty-five consecutive patients were selected from 153 cases that underwent arthroscopic rotator cuff repair for more than medium-sized posterosuperior rotator cuff tears between July 2009 and July 2012 performed with the medialized repair. All cases were available for at least 2 years of postoperative follow-up. The visual analog scale of pain, muscle strength, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and University of California-Los Angeles score were evaluated. At the final follow-up, all clinical outcomes were significantly improved. The visual analog scale score for pain improved from 6 ± 1 preoperatively to 2 ± 1 postoperatively. The range of motion increased from preoperatively to postoperatively: active forward elevation, from 134° ± 49° to 150° ± 16°; active external rotation at the side, from 47° ± 15° to 55° ± 10°; and active internal rotation, from L3 to L1. The shoulder score also improved: Constant score, from 53.5 ± 16.7 to 79 ± 10; American Shoulder and Elbow Surgeons score, from 51 ± 15 to 82 ± 8; and University of California-Los Angeles score, from 14 ± 4 to 28 ± 4. The retear cases at the final follow-up were 6 (17%). Medialized repair may be useful in cases in which anatomic bone-to-tendon repair would be difficult because of the excessive tension of the repaired tendon and a torn tendon that does not reach the anatomic insertion. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Yeo, Daniel Y T; Walton, Judie R; Lam, Patrick; Murrell, George A C
2017-03-01
Rotator cuff repair often results in significant pain postoperatively, the cause of which is undetermined. Purpose/Hypothesis: The aim of this study was to evaluate the relationship between rotator cuff tear area and postoperative pain in patients who had undergone arthroscopic rotator cuff repair. We hypothesized that larger tears would be more painful because of elevated repair tension at 1 week postoperatively but that smaller tears would be more painful because of a greater healing response, especially from 6 weeks postoperatively. Cohort study; Level of evidence, 3. A total of 1624 patients who underwent arthroscopic rotator cuff repair were included in this study. Exclusion criteria were moderate to severe osteoarthritis, isolated subscapularis repair, calcific tendinitis, synthetic patch repair, revision surgery, and retears on ultrasound at 6 months after surgery. Rotator cuff tears were subdivided into groups based on the tear size and retear rate found for each group. A modified L'Insalata questionnaire was given before surgery and at 1 week, 6 weeks, 3 months, and 6 months after surgery. Pearson and Spearman correlation coefficient tests were performed between rotator cuff tear areas and pain scores. Intraoperative rotator cuff tear areas did not correlate with pain scores preoperatively or at 1 week after surgery. A smaller tear area was associated with more frequent and severe pain with overhead activities, at rest, and during sleep as well as a poorer perceived overall shoulder condition at 6 weeks, 3 months, and 6 months after repair ( r = 0.11-0.23, P < .0001). Patients who were younger, had partial-thickness tears, and had occupational injuries experienced more pain postoperatively ( r = 0.10-0.28, P < .0001). Larger tears did not have more pain at 1 week after surgery. The retear rate was 7% in tears <2 cm 2 but reached 44% in tears >8 cm 2 . There were fewer retears with smaller tears, but they were more painful than large tears postoperatively from 6 weeks to 6 months after surgery. Smaller tears may heal more vigorously, causing more pain. Patients with smaller tears experienced more pain after rotator cuff repair compared with patients with larger tears. These findings are contrary to previous ideas about tear size and postoperative pain. Healing is likely a determinant of postoperative pain.
Tocci, Stephen L; Tashjian, Robert Z; Leventhal, Evan; Spenciner, David B; Green, Andrew; Fleming, Braden C
2008-01-01
This study determined the effect of tear size on gap formation of single-row simple-suture arthroscopic rotator cuff repair (ARCR) vs transosseous Mason-Allen suture open RCR (ORCR) in 13 pairs of human cadaveric shoulders. A massive tear was created in 6 pairs and a large tear in 7. Repairs were cyclically tested in low-load and high-load conditions, with no significant difference in gap formation. Under low-load, gapping was greater in massive tears. Under high-load, there was a trend toward increased gap with ARCR for large tears. All repairs of massive tears failed in high-load. Gapping was greater posteriorly in massive tears for both techniques. Gap formation of a modeled RCR depends upon the tear size. ARCR of larger tears may have higher failure rates than ORCR, and the posterior aspect appears to be the site of maximum gapping. Specific attention should be directed toward maximizing initial fixation of larger rotator cuff tears, especially at the posterior aspect.
C1 lateral mass screw-induced occipital neuralgia: a report of two cases.
Conroy, Eimear; Laing, Alan; Kenneally, Rory; Poynton, A R
2010-03-01
C1-2 polyaxial screw-rod fixation is a relatively new technique. While recognizing the potential for inadvertent vertebral artery injury, there have been few reports in the literature outlining all the possible complications. Aim of this study is to review all cases of C1 lateral mass screws insertion with emphasis on the evaluation of potential structures at risk during the procedure. We retrospectively reviewed all patients in our unit who had C1 lateral mass screw insertion over a 2-year period. The C1 lateral mass screw was inserted as part of an atlantoaxial stabilization or incorporated into a modular occiput/subaxial construct. Outcome measures included clinical and radiological parameters. Clinical indicators included age, gender, neurologic status, surgical indication and the number of levels stabilized. Intraoperative complications including blood loss, vertebral artery injury or dural tears were recorded. Postoperative pain distribution and neurological deficit were recorded. Radiological indicators included postoperative plain radiographs to assess sagittal alignment and to check for screw malposition or construct failure. A total of 18 lateral mass screws were implanted in 9 patients. There were three male and six female patients who had C1 lateral mass screw insertion in this unit. Two patients had atlantoaxial stabilization for C2 fracture. There were four patients with rheumatoid arthritis whose C1 lateral mass screws were inserted as part of an occipitocervical or subaxial cervical stabilization. There was no vertebral artery injury, no cerebrospinal fluid leak and minimal blood loss in all patients. Three patients developed postoperative occipital neuralgia. This neuralgia was transient, in one of the patients having settled at 6-week follow-up. In the other two patients the neuralgia was unresolved at time of latest follow-up but was adequately controlled with appropriate pain management. Postoperatively no patient had radiographic evidence of construct failure and all demonstrated excellent sagittal alignment. It has been reported that the absence of threads on the upper portion of the long shank screw may protect against neural irritation. However, insertion of the C1 lateral mass screw necessitates careful caudal retraction of the C2 dorsal root ganglion. The insertion point for the C1 lateral mass screw is at the junction of the C1 posterior arch and the midpoint of the posterior inferior part of the C1 lateral mass. Two patients in our series suffered occipital neuralgia post-insertion of C1 lateral mass screws. This highlights the potential for damage to the C2 nerve root during C1 lateral mass screw placement.
C1 lateral mass screw-induced occipital neuralgia: a report of two cases
Laing, Alan; Kenneally, Rory; Poynton, A. R.
2009-01-01
C1–2 polyaxial screw-rod fixation is a relatively new technique. While recognizing the potential for inadvertent vertebral artery injury, there have been few reports in the literature outlining all the possible complications. Aim of this study is to review all cases of C1 lateral mass screws insertion with emphasis on the evaluation of potential structures at risk during the procedure. We retrospectively reviewed all patients in our unit who had C1 lateral mass screw insertion over a 2-year period. The C1 lateral mass screw was inserted as part of an atlantoaxial stabilization or incorporated into a modular occiput/subaxial construct. Outcome measures included clinical and radiological parameters. Clinical indicators included age, gender, neurologic status, surgical indication and the number of levels stabilized. Intraoperative complications including blood loss, vertebral artery injury or dural tears were recorded. Postoperative pain distribution and neurological deficit were recorded. Radiological indicators included postoperative plain radiographs to assess sagittal alignment and to check for screw malposition or construct failure. A total of 18 lateral mass screws were implanted in 9 patients. There were three male and six female patients who had C1 lateral mass screw insertion in this unit. Two patients had atlantoaxial stabilization for C2 fracture. There were four patients with rheumatoid arthritis whose C1 lateral mass screws were inserted as part of an occipitocervical or subaxial cervical stabilization. There was no vertebral artery injury, no cerebrospinal fluid leak and minimal blood loss in all patients. Three patients developed postoperative occipital neuralgia. This neuralgia was transient, in one of the patients having settled at 6-week follow-up. In the other two patients the neuralgia was unresolved at time of latest follow-up but was adequately controlled with appropriate pain management. Postoperatively no patient had radiographic evidence of construct failure and all demonstrated excellent sagittal alignment. It has been reported that the absence of threads on the upper portion of the long shank screw may protect against neural irritation. However, insertion of the C1 lateral mass screw necessitates careful caudal retraction of the C2 dorsal root ganglion. The insertion point for the C1 lateral mass screw is at the junction of the C1 posterior arch and the midpoint of the posterior inferior part of the C1 lateral mass. Two patients in our series suffered occipital neuralgia post-insertion of C1 lateral mass screws. This highlights the potential for damage to the C2 nerve root during C1 lateral mass screw placement. PMID:19856190
Ultrasound determination of rotator cuff tear repairability
Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa
2015-01-01
Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996
Evaporation-driven instability of the precorneal tear film.
Peng, Cheng-Chun; Cerretani, Colin; Braun, Richard J; Radke, C J
2014-04-01
Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. Recently, it was proposed that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink. Copyright © 2013 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Tear test. 178.1070 Section 178.1070... Containers § 178.1070 Tear test. (a) General. The tear test must be conducted for the qualification of all of Flexible Bulk Containers design types. (b) Special preparation for the tear test. Flexible Bulk Container...
Human tears contain a chemosignal.
Gelstein, Shani; Yeshurun, Yaara; Rozenkrantz, Liron; Shushan, Sagit; Frumin, Idan; Roth, Yehudah; Sobel, Noam
2011-01-14
Emotional tearing is a poorly understood behavior that is considered uniquely human. In mice, tears serve as a chemosignal. We therefore hypothesized that human tears may similarly serve a chemosignaling function. We found that merely sniffing negative-emotion-related odorless tears obtained from women donors induced reductions in sexual appeal attributed by men to pictures of women's faces. Moreover, after sniffing such tears, men experienced reduced self-rated sexual arousal, reduced physiological measures of arousal, and reduced levels of testosterone. Finally, functional magnetic resonance imaging revealed that sniffing women's tears selectively reduced activity in brain substrates of sexual arousal in men.
Tear thinning time and topical anesthesia as assessed using the HIRCAL grid and the NCCA.
Blades, K J; Murphy, P J; Patel, S
1999-03-01
The literature contains conflicting reports of the effects of topical anesthetics on tear film stability, with some consensus that unpreserved topical anesthetics are less likely to reduce tear film stability than preserved preparations. This experiment investigated the effect of unpreserved 0.4% benoxinate hydrochloride on tear thinning time (TTT), in parallel with "real time" corneal sensitivity assessment. Tear film stability was assessed (HIRCAL grid) in parallel with real time assessment of the pharmacological activity (NCCA) of unpreserved 0.4% benoxinate hydrochloride in normal eyes. The anesthetic used did not significantly affect tear film stability. This finding is in agreement with previous investigators. Unpreserved 0.4% benoxinate hydrochloride could be used to facilitate tear film stability assessment. The experimental protocol used could also be applied to investigate the temporal relationship between anesthesia and tear film stability with preserved topical anesthetics that have been found to decrease tear film stability.
Tear exchange and contact lenses: A review
Muntz, Alex; Subbaraman, Lakshman N.; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. PMID:25575892
Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.
Pflugfelder, Stephen C
2011-12-01
To describe the cause and consequence of tear dysfunction-related corneal disease. Perspective on effects of tear dysfunction on the cornea. Evidence is presented on the effects of tear dysfunction on corneal morphology, function, and health, as well as efficacy of therapies for tear dysfunction-related corneal disease. Tear dysfunction is a prevalent eye disease and the most frequent cause for superficial corneal epithelial disease that results in corneal barrier disruption, an irregular optical surface, light scattering, optical aberrations, and exposure and sensitization of pain-sensing nerve endings (nociceptors). Tear dysfunction-related corneal disease causes irritation and visual symptoms such as photophobia and blurred and fluctuating vision that may decrease quality of life. Dysfunction of 1 or more components of the lacrimal functional unit results in changes in tear composition, including elevated osmolarity and increased concentrations of matrix metalloproteinases, inflammatory cytokines, and chemokines. These tear compositional changes promote disruption of tight junctions, alter differentiation, and accelerate death of corneal epithelial cells. Corneal epithelial disease resulting from tear dysfunction causes eye irritation and decreases visual function. Clinical and basic research has improved understanding of the pathogenesis of tear dysfunction-related corneal epithelial disease, as well as treatment outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.
Increased Tear Film Osmolarity in Systemic Lupus Erythematosus.
Duru, Necati; Altinkaynak, Hasan; Uysal, Betul Seher; Duru, Zeynep; Can, Mehmet Erol; Erten, Sukran; Yuksel, Nilay; Kalkan Akcay, Emine
2017-01-01
To evaluate tear film osmolarity in patients with systemic lupus erythematosus (SLE). A total of 55 eyes from 55 patients with SLE and 47 eyes from 47 age- and gender-matched healthy individuals were included in this study. Tear film osmolarity was evaluated with a lab-on-a-chip technique (TearLab; TearLab Corporation, San Diego, CA) in SLE patients in comparison with healthy individuals, and results were correlated to clinically available diagnostic tests for dry eye, such as tear film break-up time (BUT), Schirmer's test, and Ocular Surface Disease Index (OSDI). The mean tear film osmolarity in the SLE patients and healthy individuals was 306.02 ± 13.27 mOsm/L and 300.74 ± 9.11 mOsm/L, respectively, which made for a statistically significant difference (p = 0.020). In the SLE group, tear film osmolarity was negatively correlated with the Schirmer's test score and the BUT value (r = -0.295 p = 0.029 and r = 0.347 p = 0.009, respectively), whereas tear film osmolarity was not correlated with OSDI score (r = -0.182 p = 0.183). This study revealed that tear film hyperosmolarity and abnormal tear film function are associated with SLE.
Emotional tears facilitate the recognition of sadness and the perceived need for social support.
Balsters, Martijn J H; Krahmer, Emiel J; Swerts, Marc G J; Vingerhoets, Ad J J M
2013-02-12
The tearing effect refers to the relevance of tears as an important visual cue adding meaning to human facial expression. However, little is known about how people process these visual cues and their mediating role in terms of emotion perception and person judgment. We therefore conducted two experiments in which we measured the influence of tears on the identification of sadness and the perceived need for social support at an early perceptional level. In two experiments (1 and 2), participants were exposed to sad and neutral faces. In both experiments, the face stimuli were presented for 50 milliseconds. In experiment 1, tears were digitally added to sad faces in one condition. Participants demonstrated a significant faster recognition of sad faces with tears compared to those without tears. In experiment 2, tears were added to neutral faces as well. Participants had to indicate to what extent the displayed individuals were in need of social support. Study participants reported a greater perceived need for social support to both sad and neutral faces with tears than to those without tears. This study thus demonstrated that emotional tears serve as important visual cues at an early (pre-attentive) level.
Kan, Akinori; Oshida, Midori; Oshida, Shigemi; Imada, Masato; Nakagawa, Takumi; Okinaga, Shuji
2010-01-12
Traumatic injury and surgical meniscectomy of a medial meniscus are known to cause subsequent knee osteoarthritis. However, the difference in the prevalence of osteoarthritis caused by the individual type of the medial meniscal tear has not been elucidated. The aim of this study was to investigate what type of tear is predominantly responsible for the degradation of articular cartilage in the medial compartment of knee joints. Five hundred and forty eight cadaveric knees (290 male and 258 female) were registered in this study. The average age of cadavers at death was 78.8 years old (range: 52-103 years). The knees were macroscopically examined and their medial menisci were classified into four groups according to types of tears: "no tear", "radial tear of posterior horn", "other types of tear" and "worn-out meniscus" groups. The severity of cartilage degradation in their medial compartment of knee joints was evaluated using the international cartilage repair society (ICRS) grading system. We statistically compared the ICRS grades among the groups using Mann-Whitney U test. The knees were assigned into the four groups: 416 "no tear" knees, 51 "radial tear of posterior horn" knees, 71 "other types of tear" knees, and 10 "worn-out meniscus" knees. The knees with substantial meniscal tears showed the severer ICRS grades of cartilage degradation than those without meniscal tears. In addition, the ICRS grades were significantly severer in the "radial tear of posterior horn" group than in the "other types of tear" group, suggesting that the radial tear of posterior horn in the medial meniscus is one of the risk factors for cartilage degradation of joint surface. We have clarified the relationship between the radial tear of posterior horn in the medial meniscus and the severer grade of cartilage degradation. This study indicates that the efforts should be made to restore the anatomical role of the posterior horn in keeping the hoop strain, when patients' physical activity levels are high and the tear pattern is simple enough to be securely sutured.
Coaxial needle insertion assistant with enhanced force feedback.
De Lorenzo, Danilo; Koseki, Yoshihiko; De Momi, Elena; Chinzei, Kiyoyuki; Okamura, Allison M
2013-02-01
Many medical procedures involving needle insertion into soft tissues, such as anesthesia, biopsy, brachytherapy, and placement of electrodes, are performed without image guidance. In such procedures, haptic detection of changing tissue properties at different depths during needle insertion is important for needle localization and detection of subsurface structures. However, changes in tissue mechanical properties deep inside the tissue are difficult for human operators to sense, because the relatively large friction force between the needle shaft and the surrounding tissue masks the smaller tip forces. A novel robotic coaxial needle insertion assistant, which enhances operator force perception, is presented. This one-degree-of-freedom cable-driven robot provides to the operator a scaled version of the force applied by the needle tip to the tissue, using a novel design and sensors that separate the needle tip force from the shaft friction force. The ability of human operators to use the robot to detect membranes embedded in artificial soft tissue was tested under the conditions of 1) tip force and shaft force feedback, and 2) tip force only feedback. The ratio of successful to unsuccessful membrane detections was significantly higher (up to 50%) when only the needle tip force was provided to the user.
van der List, Jelle P.; Mintz, Douglas N.; DiFelice, Gregory S.
2017-01-01
Background: Over the past decade, there has been a resurgence of interest in anterior cruciate ligament (ACL) preservation. Proximal and distal avulsion tears have been treated with arthroscopic primary repair, while augmented repair, remnant tensioning, primary repair with biological scaffold, and remnant preservation have been proposed for different types of midsubstance tears. Currently, the incidence of these different tear types is unknown. Purpose: To propose a magnetic resonance imaging (MRI) classification system for different tear types based on clinical relevance and to assess the distribution of these different ACL tear types. Study Design: Case series; Level of evidence, 4. Methods: A retrospective search in an institutional radiographic database was performed for patients who underwent knee MRI at our institution between June 2014 and June 2016. Patients younger than 18 years and those with reports of chronic tears, partial tears, multiligamentous injuries, were excluded. Tear types were graded as proximal avulsion (distal remnant length >90% of total ligament length, type I), proximal (75%-90%, type II), midsubstance (25%-75%, type III), distal (10%-25%, type IV), and distal avulsion (<10%, type V). An orthopaedic surgeon, a radiologist, and a research fellow graded the tear type on 30 MRIs to determine reliability, and the research fellow graded all MRIs. Inter- and intraobserver reliability were measured using kappa statistics. Results: A total of 353 patients (57% male; mean age, 37.1 years; range, 18.1-81.2 years) were included. Interobserver reliability was 0.670 (95% confidence interval, 0.505-0.836), and intraobserver reliability ranged from 0.741 to 0.934. Incidence of type I tears was 16%, type II tears 27%, type III tears 52%, type IV tears 1%, and type V tears 3% (2.5% with bony avulsion). Type I tears were more common in patients older than 35 years compared with those younger than 35 years (23% vs 8%; P < .001). Conclusion: This classification system was reliable in assessing tear location in acute ACL injuries. Type I tears were seen in 16%, type II in 27%, and type III in 52% of patients in our cohort. These data suggest that there may be greater potential application for ACL preservation techniques. PMID:28680889
Nich, C; Dhiaf, N; Di Schino, M; Augereau, B
2014-11-01
Partial tearing of the infraspinatus and/or subscapularis tendon(s) is frequently associated with supraspinatus full-thickness tears. However, limited data regarding its influence on supraspinatus surgical repair is available. Our aim was to assess the functional and anatomical outcomes of open repair of supraspinatus full-thickness tears combined with adjacent partial tearing, comparatively to a control. We retrospectively identified 22 patients (22 shoulders) with a partial tear, most of them being a delamination tear, of the infraspinatus and/or subscapularis tendons associated with a complete detachment of the supraspinatus tendon. Twenty-seven patients (27 shoulders) treated for an isolated complete detachment of the supraspinatus tendon by open repair served as controls. The mean age was 58 years. A proximalized trans-osseous reinsertion of the supraspinatus tendon was combined with a curettage-closure of the delamination tear. Patients were evaluated with standardized MRI at last follow-up. At a mean of 75-month follow-up, the presence of a partial tear of either infraspinatus or subscapularis, or both, did not influence function and healing rates of supraspinatus tendon repair. Conversely to the control, when a retear occurred, the functional score tended to worsen. Preoperatively, fatty muscular degeneration was more pronounced when a partial tear was present. Fatty degeneration worsened regardless of repair healing. Open reinsertion of a supraspinatus full-thickness tear associated with a thorough treatment of partial tear of adjacent tendons led to optimal functional and anatomical mid term outcomes. Our results suggest the presence of a partial tear of adjacent tendons could be associated with poorer function in case of supraspinatus tendon re-rupture. Level III case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Tear test. 178.818 Section 178.818 Transportation... Tear test. (a) General. The tear test must be conducted for the qualification of all flexible IBC design types. (b) Special preparation for the tear test. The flexible IBC must be filled to not less than...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Tear test. 178.818 Section 178.818 Transportation... § 178.818 Tear test. (a) General. The tear test must be conducted for the qualification of all flexible IBC design types. (b) Special preparation for the tear test. The flexible IBC must be filled to not...
Lam, Sin Man; Tong, Louis; Duan, Xinrui; Petznick, Andrea; Wenk, Markus R.; Shui, Guanghou
2014-01-01
The tear film covers the anterior eye and the precise balance of its various constituting components is critical for maintaining ocular health. The composition of the tear film amphiphilic lipid sublayer, in particular, has largely remained a matter of contention due to the limiting concentrations of these lipid amphiphiles in tears that render their detection and accurate quantitation tedious. Using systematic and sensitive lipidomic approaches, we validated different tear collection techniques and report the most comprehensive human tear lipidome to date; comprising more than 600 lipid species from 17 major lipid classes. Our study confers novel insights to the compositional details of the existent tear film model, in particular the disputable amphiphilic lipid sublayer constituents, by demonstrating the presence of cholesteryl sulfate, O-acyl-ω-hydroxyfatty acids, and various sphingolipids and phospholipids in tears. The discovery and quantitation of the relative abundance of various tear lipid amphiphiles reported herein are expected to have a profound impact on the current understanding of the existent human tear film model. PMID:24287120
Numerical MHD study for plasmoid instability in uniform resistivity
NASA Astrophysics Data System (ADS)
Shimizu, Tohru; Kondoh, Koji; Zenitani, Seiji
2017-11-01
The plasmoid instability (PI) caused in uniform resistivity is numerically studied with a MHD numerical code of HLLD scheme. It is shown that the PI observed in numerical studies may often include numerical (non-physical) tearing instability caused by the numerical dissipations. By increasing the numerical resolutions, the numerical tearing instability gradually disappears and the physical tearing instability remains. Hence, the convergence of the numerical results is observed. Note that the reconnection rate observed in the numerical tearing instability can be higher than that of the physical tearing instability. On the other hand, regardless of the numerical and physical tearing instabilities, the tearing instability can be classified into symmetric and asymmetric tearing instability. The symmetric tearing instability tends to occur when the thinning of current sheet is stopped by the physical or numerical dissipations, often resulting in the drastic changes in plasmoid chain's structure and its activity. In this paper, by eliminating the numerical tearing instability, we could not specify the critical Lundquist number Sc beyond which PI is fully developed. It suggests that Sc does not exist, at least around S = 105.
Phospholipid transfer protein is present in human tear fluid.
Jauhiainen, Matti; Setälä, Niko L; Ehnholm, Christian; Metso, Jari; Tervo, Timo M T; Eriksson, Ove; Holopainen, Juha M
2005-06-07
The human tear fluid film consists of a superficial lipid layer, an aqueous middle layer, and a hydrated mucin layer located next to the corneal epithelium. The superficial lipid layer protects the eye from drying and is composed of polar and neutral lipids provided by the meibomian glands. Excess accumulation of lipids in the tear film may lead to drying of the corneal epithelium. In the circulation, phospholipid transfer protein (PLTP) and cholesteryl ester transfer protein (CETP) mediate lipid transfers. To gain insight into the formation of tear film, we investigated whether PLTP and CETP are present in human tear fluid. Tear fluid samples were collected with microcapillaries. The presence of PLTP and CETP was studied in tear fluid by Western blotting, and the PLTP concentration was determined by ELISA. The activities of the enzymes were determined by specific lipid transfer assays. Size-exclusion and heparin-affinity chromatography assessed the molecular form of PLTP. PLTP is present in tear fluid, whereas CETP is not. Quantitative assessment of PLTP by ELISA indicated that the PLTP concentration in tear fluid, 10.9 +/- 2.4 microg/mL, is about 2-fold higher than that in human plasma. PLTP-facilitated phospholipid transfer activity in tears, 15.1 +/- 1.8 micromol mL(-)(1) h(-)(1), was also significantly higher than that measured in plasma. Inactivation of PLTP by heat treatment (+58 degrees C, 60 min) or immunoinhibition abolished the phospholipid transfer activity in tear fluid. Size-exclusion chromatography of tear fluid indicated that PLTP eluted in a position corresponding to a size of 160-170 kDa. Tear fluid PLTP was quantitatively bound to Heparin-Sepharose and could be eluted as a single peak by 0.5 M NaCl. These data indicate that human tear fluid contains catalytically active PLTP protein, which resembles the active form of PLTP present in plasma. The results suggest that PLTP may play a role in the formation of the tear film by supporting phospholipid transfer.
Jeon, Yoon Sang; Kim, Rag Gyu; Shin, Sang-Jin
2018-05-16
The purpose of this study was to identify the tear pattern that could be anatomically repaired by preserving the remaining tendon on footprint and evaluate clinical outcomes of patients who underwent remaining tendon preserving cuff repair. Of 523 patients with full-thickness rotator cuff tears who underwent arthroscopic repair, 41 (7.8%) patients had repairable rotator cuff tear while preserving the remaining tendon. Among them, 31 patients were followed-up for more than 2 years, including 26 patients with posterior L-shaped tear and 5 patients with transtendinous tear patterns. Clinical outcomes were evaluated using ASES and Constant score, SANE score for patient satisfaction, and VAS for pain. MRI was taken for tendon integrity 6 months postoperatively. Of the 31 patients, 11 (35.5%) had previous injury history before rotator cuff tear, including 7 (26.9%) of the 26 patients with posterior L-shaped tear and 4 (80%) of the 5 patients with transtendinous tear. The average size of preoperative cuff tear was 17.8 ± 6.8 mm in anterior-to-posterior direction and 15.2 ± 5.1 mm in medial-to-lateral direction. ASES and Constant score, SANE score, and VAS for pain were significantly (p < 0.001) improved after remaining tendon preserving rotator cuff repair. Rotator cuff tendons of 22(84.6%) patients with posterior L-shaped tear and 4(80%) patients with transtendinous tear patterns were healed. Patients who underwent rotator cuff repair with preservation of the remaining tendon on the footprint obtained satisfactory functional outcomes. Rotator cuff tears in patients who had posterior L-shaped tear extending between supraspinatus and infraspinatus tendons or transtendinous tear pattern with substantial remaining tendon could be repaired using remaining tendon preserving repair technique. Anatomic reduction of torn cuff tendon without undue tension could be achieved using the remaining tendon preserving repair technique.
[Diagnostic value of MRI for posterior root tear of medial and lateral meniscus].
Qian, Yue-Nan; Liu, Fang; Dong, Yi-Long; Cai, Chun-Yuan
2018-03-25
To explore diagnostic value of MRI on posterior root tear of medial and lateral meniscus. From January 2012 to January 2016, clinical data of 43 patients with meniscal posterior root tear confirmed by arthroscopy were retrospective analyzed, including 25 males and 18 females, aged from 27 to 69 years old with an average age of(42.5±8.3)years old;27 cases on the right side and 16 cases on the left side. MRI examinations of 43 patients with tear of posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. MRI images were double-blinded, independently, retrospectively scored by two imaging physicians. Sensitivity, specificity and accuracy of MRI diagnosis of lateral and medial meniscus posterior root tear were calculated, and knee ligament injury and meniscal dislocation were calculated. Forty-three of 143 patients were diagnosed with meniscus posterior root tears by arthroscopy, including 19 patients with lateral tears and 24 patients with medial tears. The sensitivity, specificity and accuracy in diagnosis of posterior medial meniscus root tears for doctor A were 91.67%, 86.6% and 83.9% respectively, and for doctor B were 87.5%, 87.4% and 87.4%, 19 patients with medial meniscal protrusion and 2 patients with anterior cruciate ligament tear. The sensitivity, specificity and accuracy in diagnosis of posterior lateral meniscus root tears for doctor A were 73.7%, 79.9% and 79% respectively, and for doctor B were 78.9%, 82.3% and 82.5%, 4 patients with lateral meniscus herniation and 16 patients with cruciate ligament tear. Kappa statistics for posterior medial meniscus root tears and posterior lateral meniscus root tears were 0.84 and 0.72. MRI could effectively demonstrate imaging features of medial and lateral meniscal root tear and its accompanying signs. It could provide the basis for preoperative diagnosis of clinicians, and be worthy to be popularized. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.
... tear film can result in excess tearing or dry eye. Because tears are necessary to keep the cornea ... redness of the eye, blurred vision, frothy tears, dry eye, or crusting of the eyelashes on awakening. Treatment ...
... smooth layer) lining these tendons. A rotator cuff tear occurs when one of the tendons is torn ... Poor posture over many years Aging Rotator cuff tears TEARS Rotator cuff tears may occur in two ...
Growth and instability of a phospholipid vesicle in a bath of fatty acids
NASA Astrophysics Data System (ADS)
Dervaux, J.; Noireaux, V.; Libchaber, A. J.
2017-06-01
Using a microfluidic trap, we study the behavior of individual phospholipid vesicles in contact with fatty acids. We show that spontaneous fatty acids insertion inside the bilayer is controlled by the vesicle size, osmotic pressure difference across the membrane and fatty acids concentration in the external bath. Depending on these parameters, vesicles can grow spherically or become unstable and fragment into several daughter vesicles. We establish the phase diagram for vesicle growth and we derive a simple thermodynamic model that reproduces the time evolution of the vesicle volume. Finally, we show that stable growth can be achieved on an artificial cell expressing a simple set of bacterial cytoskeletal proteins, paving the way toward artificial cell reproduction.
Tearing relaxation and the globalization of transport in field-reversed configurations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinhauer, Loren; Barnes, D. C.
2009-09-15
Tearing instability of field-reversed configurations (FRC) is investigated using the method of neighboring equilibria. It is shown that the conducting wall position in experiment lies very close to the location needed for tearing stability. This strongly suggests that vigorous but benign tearing modes, acting globally, are the engine of continual self-organization in FRCs, i.e., tearing relaxation. It also explains the ''profile consistency'' and anomalous loss rate of magnetic flux. In effect, tearing globalizes the effect of edge-driven transport.
Cemental tear: To know what we have neglected in dental practice.
Jeng, Po-Yuan; Luzi, Arlinda Luzi; Pitarch, Rocio Marco; Chang, Mei-Chi; Wu, Yu-Hsueh; Jeng, Jiiang-Huei
2018-04-01
Cemental tear is a special kind of root surface fracture, contributing to periodontal and periapical breakdown. However, it is a challenge for doctors to diagnose, resulting in delayed or improper treatment. We reviewed the predisposing factors, location, radiographic/clinical characteristics, diagnosis and treatments of cemental tears. From the literature, patients with cemental tear were mainly males, over 60 year-old. Possible predisposing factors include gender, age, tooth type, traumatic occlusal force and vital teeth. Cemental tears were common in upper and lower anterior teeth, single or multiple, and can be present in cervical, middle and apical third of roots. Morphology of cemental tears can be either piece-shaped or U-shaped. Clinically, cemental tear shows a unitary periodontal pocket and signs/symptoms mimicking localized periodontitis, apical periodontitis and vertical root fractures. Treatment of cemental tears include scaling, root planning, root canal treatment, periodontal/periapical surgery, guided tissue regeneration, bone grafting, and intentional replantation. Recurrence of cemental tear is possible especially when the fracture involves root apex. Extraction is recommended for teeth with poor prognosis. In conclusion, cemental tears can involve both periodontal and periapical area. Dentists should understand the predisposing factors and clinical features of cemental tears for early diagnosis/treatment to prevent bone loss/tooth extraction. Copyright © 2017. Published by Elsevier B.V.
Two types of peak emotional responses to music: The psychophysiology of chills and tears
Mori, Kazuma; Iwanaga, Makoto
2017-01-01
People sometimes experience a strong emotional response to artworks. Previous studies have demonstrated that the peak emotional experience of chills (goose bumps or shivers) when listening to music involves psychophysiological arousal and a rewarding effect. However, many aspects of peak emotion are still not understood. The current research takes a new perspective of peak emotional response of tears (weeping, lump in the throat). A psychophysiological experiment showed that self-reported chills increased electrodermal activity and subjective arousal whereas tears produced slow respiration during heartbeat acceleration, although both chills and tears induced pleasure and deep breathing. A song that induced chills was perceived as being both happy and sad whereas a song that induced tears was perceived as sad. A tear-eliciting song was perceived as calmer than a chill-eliciting song. These results show that tears involve pleasure from sadness and that they are psychophysiologically calming; thus, psychophysiological responses permit the distinction between chills and tears. Because tears may have a cathartic effect, the functional significance of chills and tears seems to be different. We believe that the distinction of two types of peak emotions is theoretically relevant and further study of tears would contribute to more understanding of human peak emotional response. PMID:28387335
Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs.
Le, Brian T N; Wu, Xiao L; Lam, Patrick H; Murrell, George A C
2014-05-01
The rate of retears after rotator cuff repair varies from 11% to 94%. A retear is associated with poorer subjective and objective clinical outcomes than intact repair. This study was designed to determine which preoperative and/or intraoperative factors held the greatest association with retears after arthroscopic rotator cuff repair. Cohort study; Level of evidence, 3. This study retrospectively evaluated 1000 consecutive patients who had undergone a primary rotator cuff repair by a single surgeon using an arthroscopic inverted-mattress knotless technique and who had undergone an ultrasound evaluation 6 months after surgery to assess repair integrity. Exclusion criteria included previous rotator cuff repair on the same shoulder, incomplete repair, and repair using a synthetic polytetrafluoroethylene patch. All patients had completed the modified L'Insalata Questionnaire and underwent a clinical examination before surgery. Measurements of tear size, tear thickness, associated shoulder injury, tissue quality, and tendon mobility were recorded intraoperatively. The overall retear rate at 6 months after surgery was 17%. Retears occurred in 27% of full-thickness tears and 5% of partial-thickness tears (P < .0001). The best independent predictors of retears were anteroposterior tear length (correlation coefficient r = 0.41, P < .0001), tear size area (r = 0.40, P < .0001), mediolateral tear length (r = 0.34, P < .0001), tear thickness (r = 0.29, P < .0001), age at surgery (r = 0.27, P < .0001), and operative time (r = 0.18, P < .0001). These factors produced a predictive model for retears: logit P = (0.039 × age at surgery in years) + (0.027 × tear thickness in %) + (1 × anteroposterior tear length in cm) + (0.76 × mediolateral tear length in cm) - (0.17 × tear size area in cm(2)) + (0.018 × operative time in minutes) -9.7. Logit P can be transformed into P, which is the chance of retears at 6 months after surgery. A rotator cuff retear is a multifactorial process with no single preoperative or intraoperative factor being overwhelmingly predictive of it. Nevertheless, rotator cuff tear size (tear dimensions, tear size area, and tear thickness) showed stronger associations with retears at 6 months after surgery than did measures of tissue quality and concomitant shoulder injuries.
Hawk, Joyce; Shannon, Mary
2018-04-01
The incidence and prevalence of skin tears in long-term care (LTC) facilities has not been well established. To ascertain the point prevalence of reported skin tears, a retrospective review of incident reports was performed in 6 LTC facilities in western Pennsylvania from November 1, 2016 through December 31, 2016. Report data, including resident age; gender; mobility limitations; skin tear location, number, and cause (if known); occurrence time (7 am to 3 pm, 3 pm to 11 pm, or 11 pm to 7 am nursing shift); and history of previous skin tears, were abstracted. All data were entered into a statistical analysis program and analyzed using descriptive statistics. Period prevalence was used to determine prevalence rate; an independent t test was used to compare the presence of skin tears between genders. Differences between location and cause of skin tears were evaluated using a multinomial test of related proportions. A test of proportions was used to evaluate skin tear occurrence time (nursing shift) differences. The overall point prevalence rate was 9% (N = 1253 residents) ranging from 6 to 28 skin tears per facility. The average age of residents with a skin tear (n = 119) was 83.5 years. The majority (111, 93%) had mobility limitations. Falls accounted for 38 skin tears (31.9%), followed by propelling in a wheelchair (18, 15.1%; X2 =7.14; P = .008). Forearm skin tears (37, 31.1%) occurred significantly more frequently than lower leg skin tears (19, 16%; P = .016). Significantly more skin tears occurred during the 7 am to 3 pm shift (47, 39.5%) and 3 pm to 11 pm shift (49, 41.2%) than during the 11 pm to 7 am shift (23, 19.3%; X2 = 5.78; P <.01). The results of this study confirm skin tears are a significant problem among elderly residents in LTC, especially because the reported rate is likely lower than the actual rate. Research to further elucidate the incidence and prevalence of skin tears and associated risk factors is needed to help develop evidence-based risk assessment, classification systems, treatment guidelines, and preventive measures.
Kandhavelu, Jeyalakshmi; Demonte, Naveen Luke; Namperumalsamy, Venkatesh Prajna; Prajna, Lalitha; Thangavel, Chitra; Jayapal, Jeya Maheshwari; Kuppamuthu, Dharmalingam
2017-01-30
Aspergillus flavus and Fusarium sp. are primary causative agents of keratitis that results in corneal tissue damage leading to vision loss particularly in individuals from the tropical parts of the world. Proteins in the tear film collected from control and keratitis patients was profiled and compared. A total of 1873 proteins from control and 1400 proteins from patient tear were identified by mass spectrometry. While 847 proteins were found to be glycosylated in the patient tear, only 726 were glycosylated in control tear. And, some of the tear proteins showed alterations in their glycosylation pattern after infection. Complement system proteins, proteins specific for neutrophil extracellular traps and proteins involved in would healing were found only in the patient tear. The presence of these innate immune system proteins in the tear film of patients supports the previous data indicating the involvement of neutrophil and complement pathways in antifungal defense. High levels of wound healing proteins in keratitis patient tear implied activation of tissue repair during infection. The early appearance of the host defense proteins and wound healing response indicates that tear proteins could be used as an early marker system for monitoring the progression of pathogenesis. Identification of negative regulators of the above defense pathways in keratitis tear indicates an intricate balance of pro and anti-defense mechanisms operating in fungal infection of the eye. Tear proteins from control and mycotic keratitis patients were separated into glycoproteins and non-glycosylated proteins and then identified by mass spectrometry. Tear proteins from keratitis patients showed alteration in the glycosylation pattern indicating the alteration of glycosylation machinery due to infection. Neutrophil extracellular traps specific proteins, complement pathway proteins, as well as wound healing proteins, were found only in patient tear showing the activation of antifungal defense in the patient tear. Negative regulators of these defense pathways were also found in patient tear indicating a fine balance between pathogen clearance and host tissue destruction during fungal infection depending upon the individual specific host - pathogen interaction. This understanding could be used to predict the progression and outcome of infection. Copyright © 2016 Elsevier B.V. All rights reserved.
Concentrations of MUC16 and MUC5AC using three tear collection methods
Nichols, Jason J.
2017-01-01
Purpose To determine the optimal tear collection method for analysis of ocular surface mucins MUC5AC and MUC16. Methods Fifteen subjects without ocular surface disease were recruited. Subjects presented for tear collection on three separate days for three different tear collection methods with the order of method randomized. Methods used to collect tears from right and left eyes included Schirmer’s strip, basal tear collection, and flush tear collection. All samples from the right eyes were individually analyzed for MUC5AC whereas the left eye samples were individually analyzed for MUC16. For each individual sample, 10 μg of protein were loaded per lane into a 1% (w/v) agarose gel and run in electrophoresis buffer for 2 h. After overnight capillary transfer, membranes were incubated with either MUC5AC antibody CLH2 or MUC16 antibody OC125 for western blot analysis. Blots were developed with enhanced chemiluminescence (ECL) and signals captured with the Odyssey Fc (LI-COR). The relative amounts of MUC5AC and MUC16 were quantified with densitometry using software and compared for statistically significant differences between tear collection methods using the Kruskal–Wallis test in SPSS 22 and GraphPad Prism 7.02. Dunn’s multiple comparisons test was used for pairwise post-hoc comparisons. Results Samples containing less than 10 μg of total protein were not used for analysis which left eight samples (out of 45) unusable. The calculated MUC5AC median signal intensities from Schirmer’s strip, basal tears, and flush tears were 2.86 (n = 15, the interquartile range [IQR] = 2.54–3.21), 1.65 (n = 14, IQR = 1.34–3.1), and 1.67 (n = 9, IQR = 1.42–1.72), respectively (H = 9.5, p = 0.009). Post-hoc pairwise comparisons showed a statistically significant difference between Schirmer’s strip and flush tears (p = 0.01). The calculated MUC16 median signal intensities from Schirmer’s strip, basal tears, and flush tears were 1.88 (n = 14, IQR = 1.43–2.61), 5.24 (n = 15, IQR = 4.16–6.21), and 2.45 (n = 7, IQR = 1.85–2.48), respectively (H = 18.1, p = 0.001). Post-hoc pairwise comparison showed statistically significant differences between basal tears and Schirmer’s strip (p = 0.0003) and between basal tears and flush tears (p = 0.006). Conclusions MUC5AC and MUC16 are present in human tear fluid and can be captured using various tear collection methods. Although basal tear collection yielded the highest relative concentration of MUC16, Schirmer’s strip tear collection yielded the highest MUC5AC concentration. Therefore, the tear collection method chosen depends on the mucin of interest. PMID:28761326
Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong
2015-03-01
The healing failure rate is high for partial-thickness or small full-thickness rotator cuff tears. To retrospectively evaluate and compare outcomes after arthroscopic repair of high-grade partial-thickness and small full-thickness rotator cuff tears and factors affecting rotator cuff healing. Cohort study; Level of evidence, 3. Included in the study were 55 consecutive patients (mean age, 57.9 ± 7.2 years) who underwent arthroscopic repair for high-grade partial-thickness (n = 34) and small full-thickness (n = 21) rotator cuff tears. The study patients also underwent magnetic resonance imaging (MRI) preoperatively and computed tomography arthrography (CTA) at least 6 months postoperatively, and their functional outcomes were evaluated preoperatively and at the last follow-up (>24 months). All partial-thickness tears were repaired after being converted to full-thickness tears; thus, the repair process was almost the same as for small full-thickness tears. The tendinosis of the torn tendon was graded from the MRI images using a 4-point scale, and the reliabilities were assessed. The outcomes between high-grade partial-thickness tears that were converted to small full-thickness tears and initially small full-thickness tears were compared, and factors affecting outcomes were evaluated. The inter- and intraobserver reliabilities of the tendinosis grade were good (intraclass correlation coefficient, 0.706 and 0.777, respectively). Failure to heal as determined by CTA was observed in 12 patients with a high-grade partial-thickness tear (35.3%; complete failure in 4 and partial failure in 8) and in 3 patients with a small full-thickness tear (14.3%; complete failure in 1 and partial failure in 2). The patients with high-grade partial-thickness rotator cuff tears showed a higher tendinosis grade than did those with small full-thickness tears (P = .014), and the severity of the tendinosis was related to the failure to heal (P = .037). Tears with a higher tendinosis grade showed a 7.64-times higher failure rate (95% CI, 1.43-36.04) than did those with a lower tendinosis grade (P = .013). All functional outcome scores improved after surgery (all P < .001); however, there was no difference between groups. The high-grade partial-thickness rotator cuff tears showed more severe tendinosis compared with the small full-thickness tears in this study. Contrary to previous impressions that tear size or fatty infiltration is the factor that most influences healing, tendinosis severity assessed by preoperative MRI was the only factor associated with failure to heal, given the numbers available for analysis, in patients with partial-thickness and small full-thickness rotator cuff tears. Surgeons should pay more attention to tendon quality during repair surgery or rehabilitation in smaller rotator cuff tears, especially in high-grade partial-thickness tears with severe tendinosis. © 2014 The Author(s).
Ivanov, Vadim A
2016-02-01
The reduction of instrumental dead space is a recognized approach to preventing ventilation-induced lung injury in premature infants. However, there are no published data regarding the effectiveness of instrumental dead-space reduction in endotracheal tube (ETT) connectors. We tested the impact of the Y-piece/ETT connector pairs with reduced instrumental dead space on CO2 elimination in a model of the premature neonate lung. The standard ETT connector was compared with a low-dead-space ETT connector and with a standard connector equipped with an insert. We compared the setups by measuring the CO2 elimination rate in an artificial lung ventilated via the connectors. The lung was connected to a ventilator via a standard circuit, a 2.5-mm ETT, and one of the connectors under investigation. The ventilator was run in volume-controlled continuous mandatory ventilation mode. The low-dead-space ETT connector/Y-piece and insert-equipped standard connector/Y-piece pairs had instrumental dead space reduced by 36 and 67%, respectively. With set tidal volumes (VT) of 2.5, 5, and 10 mL, in comparison with the standard ETT connector, the low-dead-space connector reduced CO2 elimination time by 4.5% (P < .05), 4.4% (P < .01), and 7.1% (not significant), respectively. The insert-equipped standard connector reduced CO2 elimination time by 13.5, 25.1, and 16.1% (all P < .01). The low-dead-space connector increased inspiratory resistance by 17.8% (P < .01), 9.6% (P < .05), and 5.0% (not significant); the insert-equipped standard connector increased inspiratory resistance by 9.1, 8.4, and 5.9% (all not significant). The low-dead-space connector decreased expiratory resistance by 6.8% (P < .01) and 1.8% (not significant) and increased it by 1.4% (not significant); the insert-equipped standard connector decreased expiratory resistance by 1.5 and 1% and increased it by 1% (all not significant). The low-dead-space connector increased work of breathing by 4.7% (P < .01), 3.8% (P < .01), and 2.5% (not significant); the insert-equipped standard connector increased it by 0.8% (not significant), 2.5% (P < .01), and 2.8% (P < .01). Both methods of instrumental dead-space reduction led to improvements in artificial lung ventilation. Negative effects on resistance and work of breathing appeared minimal. Further testing in vivo should be performed to confirm the lung model results and, if successful, translated into clinical practice. Copyright © 2016 by Daedalus Enterprises.
Tear exchange and contact lenses: a review.
Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Budai-Szűcs, Mária; Horvát, Gabriella; Szilágyi, Barnabás Áron; Gyarmati, Benjámin; Szilágyi, András; Berkó, Szilvia; Szabó-Révész, Piroska; Sandri, Giuseppina; Bonferoni, Maria Cristina; Caramella, Carla; Soós, Judit; Facskó, Andrea; Csányi, Erzsébet
2016-01-01
Dry eye disease is a relatively common ocular problem, which causes eye discomfort and visual disorders leading to a decrease in the quality of life. The aim of this study was to find a possible excipient for eye drop formulations, which is able to stabilize the tear film. A cationic thiolated polyaspartamide polymer, poly[(N-mercaptoethylaspartamide)-co-(N-(N′,N′-dimethylaminoethyl)aspartamide)] (ThioPASP-DME), was used as a potential vehicle. Besides satisfying the basic requirements, the chemical structure of ThioPASP-DME is similar to those of ocular mucins as it is a protein-like polymer bearing a considerable number of thiol groups. The solution of the polymer is therefore able to mimic the physiological properties of the mucins and it can interact with the mucus layer via disulphide bond formation. The resultant mucoadhesion provides a prolonged residence time and ensures protective effect for the corneal/conjunctival epithelium. ThioPASP-DME also has an antioxidant effect due to the presence of the thiol groups. The applicability of ThioPASP-DME as a potential excipient in eye drops was determined by means of ocular compatibility tests and through examinations of the interactions with the mucosal surface. The results indicate that ThioPASP-DME can serve as a potential eye drop excipient for the therapy of dry eye disease. PMID:27313866
Torkildsen, Gail; Abelson, Mark B; Gomes, Paul J; McLaurin, Eugene; Potts, Susan L; Mah, Francis S
2017-03-01
To evaluate the efficacy and safety of a sustained-release dexamethasone intracanalicular insert (Dextenza™) in a model of allergic conjunctivitis. This was a randomized, double-masked, vehicle-controlled, Phase 2 study. Subjects had to have a positive conjunctival allergen challenge (CAC) reaction to allergen (bilateral +2 itching and redness on 5-point, 0-4 scales) at Visit 1, and for 2 of 3 time points on subsequent visits. Subjects who met entry criteria were randomized to receive Dextenza or PV (vehicle insert). Challenges occurred over 42 days, with efficacy assessed at 14 (primary endpoint visit), 28, and 40 days postinsertion. Outcome measures included the evaluation of ocular itching, redness, tearing, chemosis, eyelid swelling, rhinorrhea, and congestion. Twenty-eight subjects completed the study in the Dextenza group and 31 in the vehicle group. At 14 days postinsertion, Dextenza was statistically superior to PV, with least square mean differences for ocular itching of -0.76, -0.97, and -0.87 at 3, 5, and 7 min post-CAC, and for conjunctival redness of -0.46, -0.66, and -0.68 at 7, 15, and 20 min post-CAC. Clinical significance, defined as a 1-U decrease from PV, was not met for primary efficacy. Secondary endpoints, including number of subjects reporting itching and conjunctival redness, indicated superior performance of Dextenza compared with vehicle. Eleven Dextenza-treated (35.5%) and 10 vehicle-treated (30.3%) subjects each experienced a single adverse event. This Phase 2 study demonstrated preliminary efficacy and safety data of Dextenza for treatment of allergic conjunctivitis.
Gross, J M; Nascimento, G G; Araújo, V C; Bönecker, Mjs; Furuse, C
2016-04-01
This study aimed to investigate, in vitro, possible alterations on mini-implants surface after retrieval and if the cleaning process and sterilization can predispose damages. Two commercial mini-implants were tested for deformations after drilling and removing in artificial bone four times. Samples were analyzed by scanning electron microscopy, and surface alterations verified through thread and pitches deformation. To alterations caused by insertion/removal and the cleaning process and sterilization were verified in different procedures: Insertions and sterilization, only insertions, and only sterilization. Photomicrographs were analyzed in order to compare the surface characteristics. Head deformation was verified qualitatively. For a quantitative analysis, distances between threads were measured across the active part of the mini-implants. No deformation was observed in both groups. The cleaning and sterilization processes did not provoke alteration in both groups. Nevertheless, the presence of synthetic bone was noted in some samples. The mean distances between implant threads were similar after all steps in all regions in both groups. The results suggest that the tested mini-implants can be retrieved without damage of its surface after four cycles of insertion, removal, and sterilization. Orthodontic mini-implant, Redrilling, Sterilization. Mini-implants can be retrieved without damage to its surface after four cycles of insertion, removal, and sterilization in the same patient without representing a biological concern.
Prevalence of triceps tendon tears on MRI of the elbow and clinical correlation.
Koplas, Monica C; Schneider, Erika; Sundaram, Murali
2011-05-01
Triceps tendon injuries are reported to be very rare. To our knowledge, there have been no studies describing its prevalence or injury patterns on MR imaging. The purpose of this retrospective study was to determine the prevalence and patterns of triceps injuries based on a large series of consecutive MR examinations. Clinical correlation was obtained. From 801 consecutive elbow MR examinations over a 15-year period, 28 patients with 30 triceps tendon injuries were identified and graded as partial tendon tear and complete tendon tear. The patients' medical records were reviewed to determine age, gender, cause of tears, and management. The prevalence of triceps tendon injuries was 3.8%. There were 5 women and 23 men with partial or complete tears (mean age: 46.6 years; range: 2.7 to 75.1 years). The most common injury was partial tear, found in 18 patients. There were 10 patients with 12 complete tears (2 had re-torn following surgical repair). A tear was suspected in 12 out 28 (43%) patients prior to the MRI. The most common presenting symptom was pain. The most common cause was athletic injury (8 patients [29%], including weightlifting [2 patients]). Tendon tear was found to be a complication of infection in 6 patients, and in 3 patients the tears were a complication of steroid use. Thirteen tendon tears were surgically repaired (8 of these were complete tears). Triceps tendon injury is not as rare as commonly reported and may often be clinically underdiagnosed.
The Changes of Tear Status after Conventional and Wavefront-Guided IntraLASIK
Foo, Say Kiang; Kaur, Sharanjeet; Abd Manan, Faudziah; Low, Aloysius Joseph
2011-01-01
Background: IntraLASIK is a LASIK surgery that involved IntraLase femtosecond laser for the corneal flap creating. The objective of this research was to investigate and compare the changes in tear status at 1 and 3 months after undergoing conventional IntraLASIK with Bausch & Lomb PlanoScan (PS) algorithm, Bausch & Lomb Zyoptix Tissue Saving (ZTS) algorithm, and wavefront-guided (WG) IntraLASIK with VISX CustomVue. Methods: Tear status of 36 patients who were divided into 3 groups depending on the type of IntraLASIK they underwent (PS, n = 13; ZTS, n = 9; WG, n = 14) was evaluated. Tear status was determined by classifying the category of the thickness of pre-corneal tear lipid layer, non-invasive tear break-up time, and tear meniscus height. Repeated measures analysis of variance (ANOVA) and one way ANOVA were used for the statistical analyses. Results: The category of the thickness of tear lipid layer, non-invasive tear break up time and tear meniscus height were neither significantly changed after IntraLASIK for all groups nor showed significant difference among groups at 1 and 3 months post-IntraLASIK (P > 0.05). Blinking rate and palpebral aperture also had no significant changed after IntraLASIK. Conclusion: Both conventional (PS and ZTS) and WG IntraLASIK did not affect tear status up to 3 months post-IntraLASIK. WG IntraLASIK did not show superiority in preserving tear status 1 and 3 months post-surgery compared with conventional IntraLASIK. PMID:22135584
Munro, Emma L; Hickling, Donna F; Williams, Damian M; Bell, Jack J
2018-05-24
Skin tears cause pain, increased length of stay, increased costs, and reduced quality of life. Minimal research reports the association between skin tears, and malnutrition using robust measures of nutritional status. This study aimed to articulate the association between malnutrition and skin tears in hospital inpatients using a yearly point prevalence of inpatients included in the Queensland Patient Safety Bedside Audit, malnutrition audits and skin tear audits conducted at a metropolitan tertiary hospital between 2010 and 2015. Patients were excluded if admitted to mental health wards or were <18 years. A total of 2197 inpatients were included, with a median age of 71 years. The overall prevalence of skin tears was 8.1%. Malnutrition prevalence was 33.5%. Univariate analysis demonstrated associations between age (P ˂ .001), body mass index (BMI) (P < .001) and malnutrition (P ˂ .001) but not gender (P = .319). Binomial logistic regression analysis modelling demonstrated that malnutrition diagnosed using the Subjective Global Assessment was independently associated with skin tear incidence (odds ratio, OR: 1.63; 95% confidence interval, CI: 1.13-2.36) and multiple skin tears (OR 2.48 [95% CI 1.37-4.50]). BMI was not independently associated with skin tears or multiple skin tears. This study demonstrated independent associations between malnutrition and skin tear prevalence and multiple skin tears. It also demonstrated the limitations of BMI as a nutritional assessment measure. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Miyake, Kensaku; Yokoi, Norihiko
2017-01-01
To investigate influences of 3% diquafosol sodium ophthalmic solution (DQS) on ocular surface after cataract surgery and effects on postoperative dry eye. This study had two consecutive prospective study phases. The former was an observational study from before cataract surgery to 4 weeks after surgery and the latter was a randomized open-label study from 4 to 8 weeks after surgery. Subjects were 433 eyes of 433 patients undergoing cataract surgery with intraocular lens implantation. Dry eye examination of tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, total subjective symptom score (12 symptoms), and Schirmer I test were conducted before surgery and 4 weeks after surgery. Patient demographics and these examination results were used to analyze risk factors to predict postoperative dry eye. In a randomized study, 154 eyes diagnosed with dry eye postoperatively were applied either DQS or artificial tears (AT) six times daily for 4 weeks. The data of the examinations were compared. At 4 weeks after surgery, BUT was shortened significantly ( P =0.036), fluorescein staining score increased significantly ( P =0.012), but total subjective symptom score was significantly improved ( P <0.001). The majority of postoperative dry eye was shortened BUT type (53.1%). The dry eye prevalence after surgery decreased (55.7%) compared with before surgery (69.7%). Females and the patient with dry eye symptoms before surgery had significant risk factors for postoperative dry eye. In a randomized study, BUT was significantly prolonged in the DQS group ( P =0.015), but not in the AT group. Fluorescein staining score was significantly improved in both groups ( P <0.001). Total subjective symptom score was significantly decreased in the AT group ( P <0.001), but not in the DQS group. Our study suggests that cataract surgery has harmful effects on tear film stability and ocular surface, and DQS has a capability to improve them.
Li, Ying; Cui, Lian; Lee, Hyo Seok; Kang, Yeon Soo; Choi, Won; Yoon, Kyung Chul
2017-08-01
To compare the efficacy of 0.3% hypotonic and isotonic sodium hyaluronate (SH) eye drops in the treatment of experimental dry eye. Experimental dry eye was established in female C57BL/6 mice by subcutaneous scopolamine injection and an air draft. The mice were divided into three groups (n = 15): control, preservative-free 0.3% isotonic SH, and preservative-free 0.3% hypotonic SH. The tear volume, tear film break-up time, and corneal fluorescein staining scores were measured 5 and 10 days after treatment. After conjunctival tissues were excised at 10 days, the levels of interleukin (IL)-6, IL-17, interferon (IFN)-γ, and IFN-γ inducible protein-10 were determined using the multiplex immunobead assay. In addition, PAS staining and flow cytometry were performed to evaluate the counts of conjunctival goblet cells and CD4+ IFN-γ+ T cells. Mice treated with 0.3% hypotonic SH showed a significant decrease in corneal staining scores (P = 0.04) and the levels of IL-6 (16.7 ± 1.4 pg/mL, P = 0.02) and IFN-γ (46.5 ± 11.5 pg/mL, P = 0.02) compared to mice treated with 0.3% isotonic SH (IL-6; 32.5 ± 8.8 pg/mL, IFN-γ; 92.0 ± 16.0 pg/mL) at day 10. Although no significant difference in CD4+ IFN-γ+ T cell numbers was observed, goblet cell counts were higher in the hyopotonic SH group than in the isotonic SH group (P = 0.02). When compared to 0.3% isotonic SH eye drops, 0.3% hypotonic SH eye drops can be more effective by improving corneal staining scores, decreasing inflammatory molecules, and increasing goblet cell counts for experimental dry eye. These data suggest that hypotonic artificial tears may be useful as an adjunctive treatment for inflammatory dry eye.
Miyake, Kensaku; Yokoi, Norihiko
2017-01-01
Purpose To investigate influences of 3% diquafosol sodium ophthalmic solution (DQS) on ocular surface after cataract surgery and effects on postoperative dry eye. Design This study had two consecutive prospective study phases. The former was an observational study from before cataract surgery to 4 weeks after surgery and the latter was a randomized open-label study from 4 to 8 weeks after surgery. Methods Subjects were 433 eyes of 433 patients undergoing cataract surgery with intraocular lens implantation. Dry eye examination of tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, total subjective symptom score (12 symptoms), and Schirmer I test were conducted before surgery and 4 weeks after surgery. Patient demographics and these examination results were used to analyze risk factors to predict postoperative dry eye. In a randomized study, 154 eyes diagnosed with dry eye postoperatively were applied either DQS or artificial tears (AT) six times daily for 4 weeks. The data of the examinations were compared. Results At 4 weeks after surgery, BUT was shortened significantly (P=0.036), fluorescein staining score increased significantly (P=0.012), but total subjective symptom score was significantly improved (P<0.001). The majority of postoperative dry eye was shortened BUT type (53.1%). The dry eye prevalence after surgery decreased (55.7%) compared with before surgery (69.7%). Females and the patient with dry eye symptoms before surgery had significant risk factors for postoperative dry eye. In a randomized study, BUT was significantly prolonged in the DQS group (P=0.015), but not in the AT group. Fluorescein staining score was significantly improved in both groups (P<0.001). Total subjective symptom score was significantly decreased in the AT group (P<0.001), but not in the DQS group. Conclusion Our study suggests that cataract surgery has harmful effects on tear film stability and ocular surface, and DQS has a capability to improve them. PMID:28360509
González, Nerea; Iloro, Ibon; Durán, Juan A.; Elortza, Félix
2012-01-01
Purpose To characterize the tear film peptidome and low molecular weight protein profiles of healthy control individuals, and to evaluate changes due to day-to-day and individual variation and tear collection methods, by using solid phase extraction coupled to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling. Methods The tear protein profiles of six healthy volunteers were analyzed over seven days and inter-day and inter-individual variability was evaluated. The bilaterality of tear film and the effect of tear collection methods on protein profiles were also analyzed in some of these patients. MALDI-TOF MS analyses were performed on tear samples purified by using a solid phase extraction (SPE) method based on C18 functionalized magnetic beads for peptide and low molecular weight protein enrichment, focusing spectra acquisition on the 1 to 20 kDa range. Spectra were analyzed using principal component analysis (PCA) with MultiExperiment Viewer (TMeV) software. Volunteers were examined in terms of tear production status (Schirmer I test), clinical assessment of palpebral lids and meibomian glands, and a subjective OSD questionnaire before tear collection by a glass micro-capillary. Results Analysis of peptides and proteins in the 1–20 kDa range showed no significant inter-day differences in tear samples collected from six healthy individuals during seven days of monitoring, but revealed subtle intrinsic inter-individual differences. Profile analyses of tears collected from the right and left eyes confirmed tear bilaterality in four healthy patients. The addition of physiologic serum for tear sample collection did not affect the peptide and small protein profiles with respect to the number of resolved peaks, but it did reduce the signal intensity of the peaks, and increased variability. Magnetic beads were found to be a suitable method for tear film purification for the profiling study. Conclusions No significant variability in tear peptide and protein profiles below 20 kDa was found in healthy controls over a seven day period, nor in right versus left eye profiles from the same individual. Subtle inter-individual differences can be observed upon tear profiling analysis and confirm intrinsic variability between control subjects. Addition of physiologic serum for tear collection affects the proteome and peptidome in terms of peak intensities, but not in the composition of the profiles themselves. This work shows that MALDI-TOF MS coupled with C18 magnetic beads is an effective and reproducible methodology for tear profiling studies in the clinical monitoring of patients. PMID:22736947
Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee
In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.
Mabuchi, Kunihiko
2013-01-01
We are currently developing an artificial arm/hand system which is capable of sensing stimuli and then transferring these stimuli to users as somatic sensations. Presently, we are evoking the virtual somatic sensations by electrically stimulating a sensory nerve fiber which innervates a single mechanoreceptor unit at the target area; this is done using a tungsten microelectrode that was percutaneously inserted into the use's peripheral nerve (a microstimulation method). The artificial arm/hand system is composed of a robot hand equipped with a pressure sensor system on its fingers. The sensor system detects mechanical stimuli, which are transferred to the user by means of the microstimulation method so that the user experiences the stimuli as the corresponding somatic sensations. In trials, the system worked satisfactorily and there was a good correlation between the pressure applied to the pressure sensors on the robot fingers and the subjective intensities of the evoked pressure sensations.
Zickfeld, Janis H; Schubert, Thomas W
2018-01-31
Recent work investigated the inter-individual functions of emotional tears in depth. In one study (Van de Ven, N., Meijs, M. H. J., & Vingerhoets, A. (2017). What emotional tears convey: Tearful individuals are seen as warmer, but also as less competent. British Journal of Social Psychology, 56(1), 146-160. Https://doi.org/10.1111/bjso.12162) tearful individuals were rated as warmer, and participants expressed more intentions to approach and help such individuals. Simultaneously, tearful individuals were rated as less competent, and participants expressed less intention to work with the depicted targets. While tearful individuals were perceived as sadder, perceived sadness mediated only the effect on competence, but not on warmth. We argue that tearful individuals might be perceived as warm because they are perceived as feeling moved and touched. We ran a pre-registered extended replication of Van de Ven et al. Results replicate the warmth and helping findings, but not the competence and work effects. The increase in warmth ratings was completely mediated by perceiving feeling moved and touched. Possible functions of feeling moved and touched with regard to emotional tears are discussed.
Lee, Ryan K L; Griffith, James F; Ng, Alex W H; Nung, Ryan C H; Yeung, David K W
2016-01-01
The purpose of this study was to assess the effects of traction during MR arthrography of the wrist on joint space widening, cartilage visibility, and detection of tears of the triangular fibrocartilage complex (TFCC) and intrinsic ligaments. A prospective study included 40 wrists in 39 patients (25 men, 14 women; mean age, 35 years). MR arthrography was performed with a 3-T MRI system with and without axial traction. Two radiologists independently measured wrist and carpal joint space widths and semiquantitatively graded articular cartilage visibility. Using conventional arthrography as the reference standard and working in consensus, they assessed for the presence of tears of the TFCC, lunotriquetral ligament (LTL), and scapholunate ligament (SLL). Visibility of a tear before traction was compared with visibility after traction. With traction, all joint spaces in the wrist and carpus were significantly widened (change, 0.15-1.01 mm; all p < 0.006). Subjective cartilage visibility of all joint spaces improved after traction (all p ≤ 0.048) except for that of the radioscaphoid space, which was well visualized even before traction. Conventional arthrography depicted 24 TFCC tears, seven LTL tears, and three SLL tears. The accuracy of tear detection improved after traction for the TFCC (98% after traction vs 83% before traction), the LTL (100% vs 88%), and the SLL (100% vs 95%). Tear visibility improved after traction for 54% of TFCC tears, 71% of LTL tears, and 66% of SLL tears. Wrist MR arthrography with axial traction significantly improved the visibility of articular cartilage and the detection and visibility of tears of the TFCC and intrinsic ligaments. The results favor more widespread use of traction during MR arthrography of the wrist.
Evaluating tear clearance rate with optical coherence tomography.
Garaszczuk, Izabela K; Mousavi, Maryam; Cervino Exposito, Alejandro; Bartuzel, Maciej M; Montes-Micó, Robert; Iskander, D Robert
2018-02-01
To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. TCR was classified as the percentage decrease of subject's inferior tear meniscus height 30s after instillation of 5μl 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean±standard deviation) 25.5±4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR estimation based on dynamic measurements of the lower tear meniscus with OCT. Estimates of TCR were contrasted against subject age and tear film measures commonly used for dry eye diagnosis, which includes OSDI score, fluorescein tear film break-up time (FBUT), tear meniscus height (TMH), blinking frequency, tear film osmolarity and corneal staining. The group mean TCR was 29±13% and 36±19% respectively after 30 and 60s margin after saline solution instillation. Statistically significant correlations were found between TCR and FBUT (r 2 =0.319, p<0.001), blinking frequency (r 2 =0.138, p<0.01), tear film osmolarity (r 2 =0.133, p<0.01) and subject's age (r 2 =0.095, p<0.05). Anterior segment optical coherence tomography allows following changes of tear meniscus morphology post saline solution instillation and evaluating the TCR. OCT based TCR might be used as additional measure of the lacrimal functional unit. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Predicting Rotator Cuff Tears Using Data Mining and Bayesian Likelihood Ratios
Lu, Hsueh-Yi; Huang, Chen-Yuan; Su, Chwen-Tzeng; Lin, Chen-Chiang
2014-01-01
Objectives Rotator cuff tear is a common cause of shoulder diseases. Correct diagnosis of rotator cuff tears can save patients from further invasive, costly and painful tests. This study used predictive data mining and Bayesian theory to improve the accuracy of diagnosing rotator cuff tears by clinical examination alone. Methods In this retrospective study, 169 patients who had a preliminary diagnosis of rotator cuff tear on the basis of clinical evaluation followed by confirmatory MRI between 2007 and 2011 were identified. MRI was used as a reference standard to classify rotator cuff tears. The predictor variable was the clinical assessment results, which consisted of 16 attributes. This study employed 2 data mining methods (ANN and the decision tree) and a statistical method (logistic regression) to classify the rotator cuff diagnosis into “tear” and “no tear” groups. Likelihood ratio and Bayesian theory were applied to estimate the probability of rotator cuff tears based on the results of the prediction models. Results Our proposed data mining procedures outperformed the classic statistical method. The correction rate, sensitivity, specificity and area under the ROC curve of predicting a rotator cuff tear were statistical better in the ANN and decision tree models compared to logistic regression. Based on likelihood ratios derived from our prediction models, Fagan's nomogram could be constructed to assess the probability of a patient who has a rotator cuff tear using a pretest probability and a prediction result (tear or no tear). Conclusions Our predictive data mining models, combined with likelihood ratios and Bayesian theory, appear to be good tools to classify rotator cuff tears as well as determine the probability of the presence of the disease to enhance diagnostic decision making for rotator cuff tears. PMID:24733553
Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.
Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P
2017-08-01
To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p<0.05), with no significant difference between treatments (p=0.41). Both treatments improved lipid layer thickness (both p≤0.01), but effected no significant change in non-invasive tear film break-up time or tear evaporation rate (all p>0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Kan, Emrah; Kan, Elif K; Okuyucu, Ali
2017-08-30
To compare the central corneal thickness (CCT), intraocular pressure (IOP), and tear insulin-like growth factor 1 (IGF-1) levels between patients with acromegaly and a control group and to evaluate the possible effect of tear IGF-1 and duration of the disease on CCT and IOP. We included 31 patients with acromegaly (study group) and 40 age- and sex-matched controls in the study. Patients with acromegaly were divided into 2 subgroups based on disease status (active/inactive). All participants underwent complete ophthalmologic evaluation including CCT and IOP values. Basal tear samples were collected from both groups and tear IGF-1 levels were measured. The CCT, IOP, and tear IGF-1 levels were compared between groups and subgroups and the association between tear IGF-I levels and ocular parameters (CCT, IOP) and disease duration were also evaluated. Central corneal thickness, IOP, and tear IGF-1 levels did not show a significant difference between study and control groups. We also did not find a significant difference in terms of CCT, IOP, or tear IGF-1 levels between subgroups of patients. Correlation analysis did not show an association between the duration of disease and tear IGF-1 levels with CCT or IOP. There was no significant difference in tear IGF-1 levels between patients with acromegaly and controls. Additionally, there was no correlation between disease duration and tear IGF-1 levels with CCT or IOP levels. This lack of association may suggest that tear IGF-1 levels might not have an effect on CCT or IOP findings in patients with acromegaly.
Shah, Shivam A; Kormpakis, Ioannis; Cavinatto, Leonardo; Killian, Megan L; Thomopoulos, Stavros; Galatz, Leesa M
2017-12-01
Large rotator cuff tear size and advanced muscle degeneration can affect reparability of tears and compromise tendon healing. Clinicians often rely on direct measures of rotator cuff tear size and muscle degeneration from magnetic resonance imaging (MRI) to determine whether the rotator cuff tear is repairable. The objective of this study was to identify the relationship between gene expression changes in rotator cuff muscle degeneration to standard data available to clinicians. Radiographic assessment of preoperative rotator cuff tear severity was completed for 25 patients with varying magnitudes of rotator cuff tears. Tear width and retraction were measured using MRI, and Goutallier grade, tangent (tan) sign, and Thomazeau grade were determined. Expression of myogenic-, adipogenic-, atrophy-, and metabolism-related genes in biopsied muscles were correlated with tear width, tear retraction, Goutallier grade, tan sign, and Thomazeau grade. Tear width positively correlated with Goutallier grade in both the supraspinatus (r = 0.73) and infraspinatus (r = 0.77), along with tan sign (r = 0.71) and Thomazeau grade (r = 0.68). Decreased myogenesis (Myf5), increased adipogenesis (CEBPα, Lep, Wnt10b), and decreased metabolism (PPARα) correlated with radiographic assessments. Gene expression changes suggest that rotator cuff tears lead to a dramatic molecular response in an attempt to maintain normal muscle tissue, increase adipogenesis, and decrease metabolism. Fat accumulation and muscle atrophy appear to stem from endogenous changes rather than from changes mediated by infiltrating cells. Results suggest that chronic unloading of muscle, induced by rotator cuff tear, disrupts muscle homeostasis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2808-2814, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Lee, Ro Woon; Choi, Soo-Jung; Lee, Man Ho; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Ki Won
2016-12-01
To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears.
Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill
2016-07-01
To compare the frequency of atraumatic ligamentum teres (LT) tear in professional ballet dancers with that of athletes, and to determine the relationship with clinical and imaging findings. Forty-nine male and female professional ballet dancers (98 hips) and 49 age and sex-matched non-dancing athletes (98 hips) completed questionnaires on hip symptoms and physical activity levels, underwent hip rotation range of movement (ROM) and hypermobility testing, and 3.0-Tesla magnetic resonance imaging (3 T MRI) on both hips to detect LT tears, acetabular labral tears, and articular cartilage defects, and to measure the lateral centre edge angles (LCE). A higher frequency of LT tear was found in dancers (55 %) compared with athletes (22 %, P = 0.001). The frequency and severity of LT tears in dancers increased with older age (P = 0.004, P = 0.006, respectively). The Hip and Groin Outcome Score (HAGOS) pain scores or hip rotation ROM did not differ significantly among participants with normal, partial, or complete tears of LT (P > 0.01 for all). Neither the frequency of generalised joint hypermobility (P = 0.09) nor the LCE angles (P = 0.32, P = 0.16, left and right hips respectively) differed between those with and those without LT tear. In most hips, LT tear co-existed with either a labral tear or a cartilage defect, or both. The higher frequency of atraumatic LT tears in professional ballet dancers suggests that the LT might be abnormally loaded in ballet, and caution is required when evaluating MRI, as LT tears may be asymptomatic. A longitudinal study of this cohort is required to determine if LT tear predisposes the hip joint to osteoarthritis.
Patient acceptability of tear collection in the primary healthcare setting.
Quah, Joanne Hui Min; Tong, Louis; Barbier, Sylvaine
2014-04-01
The primary healthcare setting is well placed for health screening. Tear fluid composition gives valuable information about the eye and systemic health, and there is now significant interest in the potential application of tears as a tool for health screening; however, the acceptability of tear collection in the primary healthcare setting as compared with other methods of human sample collection has not been previously addressed. The objective of this study was to evaluate the patient acceptability of tear collection in a primary healthcare setting. This was a cross-sectional study on 383 adult patients seeking primary healthcare, who were not diabetic and were not attending for an eye-related complaint. Tear collection was done using Schirmer strips, and an interviewer-administered questionnaire was conducted to collate information on the pain score (0-10) of the Schirmer tear collection, as well as to score the pain associated with their previous experience of antecubital venous puncture and finger prick test. The pain score for Schirmer tear collection was significantly lower (p < 0.001) than antecubital venous puncture but higher (p < 0.001) than finger prick. The pain scores for all three procedures were significantly higher in participants of younger age, female gender, and higher education level. Among the participants, 70% did not mind their tears being collected to screen for eye problems, whereas only 38% did not mind this procedure being performed for general health screening. Nevertheless, 69% of the participants preferred tear to urine collection, and 74% of participants preferred tear to blood collection. Tear collection using Schirmer strips is a highly acceptable form of investigation that has the potential for use in health screening in the primary healthcare setting. This study has implications on using tear collection as a method of ocular and systemic health screening in the primary healthcare setting.
Tear-Duct Obstruction and Surgery
... Staying Safe Videos for Educators Search English Español Tear-Duct Obstruction and Surgery KidsHealth / For Parents / Tear- ... year old with little or no treatment. About Tear Ducts Our eyes are continually exposed to dust, ...
... JavaScript. Watery eyes means you have too many tears draining from the eyes. Tears help keep the surface of the eye moist. ... the eye. Causes Your eyes are always making tears. These tears leave the eye through a small ...
Performance of advanced trauma life support procedures in microgravity
NASA Technical Reports Server (NTRS)
Campbell, Mark R.; Billica, Roger D.; Johnston, Smith L 3rd; Muller, Matthew S.
2002-01-01
BACKGROUND: Medical operations on the International Space Station will emphasize the stabilization and transport of critically injured personnel and so will need to be capable of advanced trauma life support (ATLS). METHODS: We evaluated the ATLS invasive procedures in the microgravity environment of parabolic flight using a porcine animal model. Included in the procedures evaluated were artificial ventilation, intravenous infusion, laceration closure, tracheostomy, Foley catheter drainage, chest tube insertion, peritoneal lavage, and the use of telemedicine methods for procedural direction. RESULTS: Artificial ventilation was performed and appeared to be unaltered from the 1-G environment. Intravenous infusion, laceration closure, percutaneous dilational tracheostomy, and Foley catheter drainage were achieved without difficulty. Chest tube insertion and drainage were performed with no more difficulty than in the 1-G environment due to the ability to restrain patient, operator and supplies. A Heimlich valve and Sorenson drainage system were both used to provide for chest tube drainage collection with minimal equipment, without the risk of atmospheric contamination, and with the capability to auto-transfuse blood drained from a hemothorax. The use of telemedicine in chest tube insertion was demonstrated to be useful and feasible. Peritoneal lavage using a percutaneous technique, although requiring less training to perform, was found to be dangerous in weightlessness due to the additional pressure of the bowel on the anterior abdominal wall creating a high risk of bowel perforation. CONCLUSIONS: The performance of ATLS procedures in microgravity appears to be feasible with the exception of diagnostic peritoneal lavage. Minor modifications to equipment and techniques are required in microgravity to effect surgical drainage in the presence of altered fluid dynamics, to prevent atmospheric contamination, and to provide for the restraint requirements. A parabolic simulation system was developed for equipment and procedure verification, physiological research, and possible crew medical officer training in the future.
Blind urethral catheterization in trauma patients suffering from lower urinary tract injuries.
Shlamovitz, Gil Z; McCullough, Lynne
2007-02-01
The goals of our study were to review all cases of urethral and bladder trauma that presented to the University of California, Los Angeles (UCLA) Medical Center between January 1998 and August 2005 and determine (1) the clinical characteristics of patients with urethral and/or bladder injuries as well as the sensitivities of those clinical characteristics; (2) whether or not a blind attempt to insert a urethral catheter was performed; and (3) whether there is any evidence that a blind attempt to insert a urethral catheter worsened the initial urinary tract injury. This is a retrospective chart review. The study cohort comprised 46 patients with a mean age of 30 years, including 36 men (78.2%) and 10 women (21.8%). Bladder tears were found in 33 patients, 10 patients had urethral lacerations, and 3 patients had combined bladder and urethral lacerations. The most sensitive finding for urinary bladder or urethral injury was the presence of gross hematuria in the urethral catheter (100%, 95% confidence interval [CI] 0.63-0.89). Blinded insertion of a urethral catheter was attempted in 30 (90.9%, 95% CI 0.75-0.98) patients who suffered from urinary bladder injury, 6 (50%, 95% CI 0.26-0.87) patients who suffered from urethral injury and 1 (33%, 95% CI 0.0-0.9) patient who suffered from a combined urinary bladder and urethral injuries. We did not find evidence that a blind attempt to insert a urethral catheter worsened the initial urinary injury. Gross hematuria in the urethral catheter was the most sensitive sign for the presence of a urethral or urinary bladder injury in our study cohort, and often the only sign of such an injury. We found no evidence that a blind attempt to insert a urethral catheter in patients suffering from urethral and or urinary bladder injuries worsened the initial injury. Larger studies will be needed to determine the safety of blind urethral catheterization in patients that are suspected to suffer from a lower urological trauma. It is our opinion that the current guidelines should be revised to better reflect the current knowledge, technologies, and clinical practice.
Roussignol, X; Gauthe, R; Rahali, S; Mandereau, C; Courage, O; Duparc, F
2015-09-01
Arthroscopic treatment of tears in the middle and posterior parts of the medial meniscus can be difficult when the medial tibiofemoral compartment is tight. Passage of the instruments may damage the cartilage. The primary objective of this cadaver study was to perform an arthroscopic evaluation of medial tibiofemoral compartment opening after pie-crusting release (PCR) of the superficial medial collateral ligament (sMCL) at its distal insertion on the tibia. The secondary objective was to describe the anatomic relationships at the site of PCR (saphenous nerve, medial saphenous vein). We studied 10 cadaver knees with no history of invasive procedures. The femur was held in a vise with the knee flexed at 45°, and the medial aspect of the knee was dissected. PCR of the sMCL was performed under arthroscopic vision, in the anteroposterior direction, at the distal tibial insertion of the sMCL, along the lower edge of the tibial insertion of the semi-tendinosus tendon. Continuous 300-N valgus stress was applied to the ankle. Opening of the medial tibiofemoral compartment was measured arthroscopically using graduated palpation hooks after sequential PCR of the sMCL. The compartment opened by 1mm after release of the anterior third, 2.3mm after release of the anterior two-thirds, and 3.9mm after subtotal release. A femoral fracture occurred in 1 case, after completion of all measurements. Both the saphenous nerve and the medial saphenous vein were located at a distance from the PCR site in all 10 knees. PCR of the sMCL is chiefly described as a ligament-balancing method during total knee arthroplasty. This procedure is usually performed at the joint line, where it opens the compartment by 4-6mm at the most, with some degree of unpredictability. PCR of the sMCL at its distal tibial insertion provides gradual opening of the compartment, to a maximum value similar to that obtained with PCR at the joint space. The lower edge of the semi-tendinosus tendon is a valuable landmark for PCR of the distal sMCL. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
McMonnies, Charles W
2017-12-01
This review examines the evidence for and significance of pre-conjunctival tear temperature being higher than central pre-corneal temperature with associated more rapid evaporation of warmer pre-conjunctival tears in normal eyes but especially in hyperemic dry eye disease. PubMed searches using the terms "evaporative dry eye," "conjunctival tear evaporation," "tear evaporation," and "dry eye conjunctival hyperemia" indicated 157, 49, 309, and 96 potentially relevant papers, respectively. Selections from these lists were the basis for examining the significance of the evidence relevant to pre-conjunctival tear layer temperature and evaporation. There is evidence supporting an amplifying inflammatory and para-inflammatory hyperemia dry eye cascade, which increases pre-conjunctival tear temperature and the risk of accelerated pre-conjunctival tear evaporation with exacerbated osmolarity elevation and inflammation. Dry eye cascade amplification is consistent with increases in symptoms and inflammatory as well as para-inflammatory hyperemia toward the end of the waking day. Apart from age-related conjunctivochalasis, dry eye-related conjunctival epithelial cell pathology including reduced goblet cell numbers and associated mucin deficiency, squamous metaplasia, and increased separation of cell layers could help to destabilize tears and facilitate evaporation as part of an amplifying cascade. Greater difficulty in assessing conjunctival tear break up may contribute to an underestimation of a role for faster evaporation of pre-conjunctival tears in dry eye disease and help explain any non-correspondence between symptoms and corneal signs of dry eye disease. Success with anti-inflammatory therapies for dry eye disease may be at least partly due to reductions in conjunctival hyperemia and deamplification of evaporative cascades. Conjunctival inflammatory hyperemia in other diseases may contribute to accelerated pre-conjunctival tear evaporation and the risk of tear-deficiency- associated exacerbation of those diseases including impaired responses to therapeutic approaches to them. Similarly, postsurgical conjunctival inflammation and associated acceleration of tear evaporation could contribute to delayed wound healing.
Eperon, Simone; Berguiga, Marouen; Ballabeni, Pierluigi; Guex-Crosier, Catherine; Guex-Crosier, Yan
2014-09-01
To prospectively investigate patients with seasonal allergic conjunctivitis (SAC) during the pollen season and test associations between tears total IgE, eotaxin concentrations, and SAC severity. Enrolled patients presented ocular symptoms and clinical signs of SAC at the time of presentation. Ocular itching, hyperaemia, chemosis, eyelid swelling, and tearing were scored, and the sum of these scores was defined as the clinical score. Conjunctival papillae were separately graded. We measured eotaxin concentration in tears by an enzyme-linked immunosorbent assay (ELISA) and total tear IgE by Lacrytest strip. Among thirty patients (30 eyes), 11 showed neither tear IgE nor tear eotaxin, while 15 out of 19 patients with positive IgE values presented a positive amount of eotaxin in their tears (Fisher's test: p < 0.001). The mean eotaxin concentration was 641 ± 154 (SEM) pg/ml. In patients with no amount of tear IgE, we observed a lower conjunctival papilla grade than in patients whose tears contained some amount of IgE (trend test: p = 0.032). In the 15 patients whose tear eotaxin concentration was null, tear IgE concentration was 5.3 ± 3.5 arbitrary units; in the other 15 patients whose eotaxin was positive, IgE reached 21 ± 4.3 arbitrary U (Mann-Whitney: p < 0.001). We measured 127 ± 47 pg/ml eotaxin in patients with no history of SAC but newly diagnosed as suffering from SAC, and 852 ± 218 pg/ml eotaxin in patients with a known SAC (p = 0.008). In contrast, tear IgE concentrations of both groups did not differ statistically significantly (p = 0.947). If IgE and eotaxin secreted in tears are major contributors in SAC pathogenesis, they however act at different steps of the process.
Interferometric measurements of the tear film irregularities on the human cornea
NASA Astrophysics Data System (ADS)
Szczesna, Dorota H.; Jaronski, Jaroslaw; Kasprzak, Henryk T.; Stenevi, Ulf
2005-09-01
The pre-ocular tear film is the most anterior refractive surface of the eye. Its stability plays an important role in the condition of vision from the optical and physiological point of view. If the eye is opened for a significantly long time or suffers from an anormalities in tear production, there appear isolated dry islands - break-ups - with a random distribution in the continuous lacrimal film. We applied an interferometric method - Lateral Shearing Technique for investigating the tear film stability and the smoothness of the tear film surface. This method is non-invasive and it is characterised by the high accuracy and sensitivity. Interferometry allows dynamic measurements of the tear film stability in real time by observation of interference fringes. The evaporation of tears and appearance of the breakups causes changes in the fringe geometry. Fast Fourier Transform has been used for quantitative assessment of the fringe smoothness and as a consequence of the tear film surface geometry. This paper presents the method used for quantitative evaluation of the tear film distribution on the cornea. Examples of interferograms recorded on eyes of patients with healthy eyes, suffering from dry eye syndrome and wearing contact lenses are also given. With our technique we were able to observe distinct differences in stability of the tear film between healthy and dry eyes, and the tear film on contact lenses.
Bone mineralization changes of the glenoid in shoulders with symptomatic rotator cuff tear.
Harada, Yohei; Yokoya, Shin; Akiyama, Yuji; Mochizuki, Yu; Ochi, Mitsuo; Adachi, Nobuo
2018-06-06
Computed tomography osteoabsorptiometry (CTO) is a method to analyze the stress distribution in joints by measuring the subchondral bone density. The purpose of this study was to evaluate the bone mineralization changes of the glenoid in shoulders with rotator cuff tears by CTO and to evaluate whether rotator cuff tears are associated with stress changes in the glenoid. In total, 32 patients, who were diagnosed with unilateral rotator cuff tears and underwent arthroscopic rotator cuff repair, were enrolled in this study. They underwent CT scanning of both shoulders pre-operatively and the glenoid was evaluated using CTO. Hounsfield units (HU) in seven areas of the glenoid were compared between the affected and unaffected sides. The central area of the glenoid on the affected side had significantly lower HU than on the unaffected side among all patients. Focusing on the rotator cuff tear size and the subscapularis tendon, only patients with larger cuff tears or with subscapularis tendon tears showed significantly lower HU in the central area of the affected side. This study showed a decrease in bone mineralization density in the central glenoid in shoulders with rotator cuff tear. This change was observed in the case of larger cuff tears and subscapularis tendon tears. Our results help clarify the changes in stress distribution in the shoulder joint caused by symptomatic rotator cuff tears.
New testing options for diagnosing and grading dry eye disease.
Foulks, Gary N; Pflugfelder, Stephen C
2014-06-01
To describe new options for diagnosis and severity grading of dry eye disease. Perspective on technological advancements to identify tear dysfunction and their value in diagnosing and grading dry eye disease. Evidence is presented on new and evolving technologies to measure tear stability, composition, and meniscus height and their role in dry eye diagnosis and therapeutic efficacy grading is assessed. Evolving concepts regarding pathogenesis and new technologies to evaluate the tears and ocular surface have improved the ability to diagnose, classify, and grade the severity of dry eye disease. New technologies include noninvasive imaging of tear stability and tear meniscus height as a measure of tear volume and tear composition (osmolarity, lacrimal factors, inflammatory mediators, growth and differentiation factors). Approved tests, such as tear osmolarity and tear imaging, are being integrated into clinical practice and may eventually supplant certain traditional tests that have greater variability and less sensitivity. Other tests, such as molecular assays of tears and conjunctival cells, are currently being used in studies investigating pathogenesis and therapeutic mechanism of action. They may eventually translate to routine clinical practice. New technologies have emerged that can noninvasively evaluate the tears and measure disease-associated compositional changes. These tests are being integrated into clinical practice and therapeutic trials for diagnosis, classification, and severity grading of dry eye disease. Copyright © 2014 Elsevier Inc. All rights reserved.
Partial articular-sided rotator cuff tears: in situ repair versus tear completion prior to repair.
Sethi, Paul M; Rajaram, Arun; Obopilwe, Elifho; Mazzocca, Augustus D
2013-06-01
Uncertainty exists over the ideal surgical treatment method for partial articular-sided rotator cuff tears, with options ranging from debridement to in situ repair to tear completion prior to repair. The purpose of this study was to determine whether in situ repair was a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. Fourteen fresh-frozen cadaveric shoulders were dissected. Partial articular-sided tears were created and repaired using in situ repair or tear completion prior to the repair. Strain and displacement were measured at 45°, 60°, and 90° of glenohumeral abduction. Testing was performed with a load of 100 N applied for 30 cycles. Data from the biomechanical testing displayed 4 conditions that showed improved characteristics of in situ repair over completion and repair: bursal-sided strain anteriorly at 45°, bursal-sided strain anteriorly at 90°, bursal-sided displacement anteriorly at 45°, and bursal-sided displacement anteriorly at 90°. The data indicate that in situ repair is a viable biomechanical treatment option compared with tear completion prior to repair of partial articular-sided rotator cuff tears. When clinically appropriate, the in situ repair may offer some biomechanical advantages, with lower strain and displacement observed on the bursal side compared with tear completion prior to repair. Copyright 2013, SLACK Incorporated.
... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabau, Adrian S; Mirmiran, Seyed; Glaspie, Christopher
Hot-tearing is a major casting defect that is often difficult to characterize, especially for multicomponent Al alloys used for cylinder head castings. The susceptibility of multicomponent Al-Cu alloys to hot-tearing during permanent mold casting was investigated using a constrained permanent mold in which the load and displacement was measured. The experimental results for hot tearing susceptibility are compared with those obtained from a hot-tearing criterion based temperature range evaluated at fraction solids of 0.87 and 0.94. The Cu composition was varied from approximately 5 to 8 pct. (weight). Casting experiments were conducted without grain refining. The measured load during castingmore » can be used to indicate the severity of hot tearing. However, when small hot-tears are present, the load variation cannot be used to detect and assess hot-tearing susceptibility.« less
Sphincter tears in primiparous women: Is age a factor?
BOWLING, C. Bryce; WHEELER, Thomas L.; GERTEN, Kimberly A.; CHAPMAN, Victoria R.; BURGIO, Kathryn L.; RICHTER, Holly E.
2011-01-01
Introduction and Hypothesis Anal sphincter tears during vaginal delivery may result in serious sequelae. We examined whether younger primiparous patients were at increased risk for sphincter tears during vaginal delivery. Methods Data from an obstetric automated record were analyzed. Primiparous women delivering term infants (n = 5,937) were included to test for an association between age and sphincter tear rates. Three age groups were considered: young adolescents (≤16 years), older adolescents (17-20 years) and adults (≥21 years). Results No significant difference was found in tear rates among age cohorts (9.2%, 8.0%, and 9.6% respectively; p = 0.12). Logistic regression modeling revealed that young adolescents were not more likely to have sphincter tears compared to older cohorts. Conclusions Younger adolescents may not be at increased risk of anal sphincter tears. Decisions regarding interventions to decrease sphincter tears during vaginal delivery should not be made on the basis of maternal age alone. PMID:18985267
Vyas, Dharmesh; Harner, Christopher D
2012-06-01
Root tears are a subset of meniscal injuries that result in significant knee joint pathology. Occurring on either the medial or lateral side, root tears are defined as radial tears or avulsions of the posterior horn attachment to bone. After a root tear, there is a significant increase in tibio-femoral contact pressure concomitant with altered knee joint kinematics. Previous cadaver studies from our institution have shown that root repair of the medial meniscus is successful in restoring joint biomechanics to within normal limits. Indications for operative management of meniscal root tears include (1) a symptomatic medial meniscus root tear with minimal arthritis and having failed non-operative treatment, and (2) a lateral root tear in associated with an ACL tear. In this review, we describe diagnosis, imaging, patient selection, and arthroscopic surgical technique of medial and lateral meniscus root injuries. In addition we highlight the pearls of repair technique, associated complications, post-operative rehabilitation regimen, and expected outcomes.
NASA Astrophysics Data System (ADS)
van Haaften, W. M.; Kool, W. H.; Katgerman, L.
2002-10-01
One of the major problems during direct chill (DC) casting is hot tearing. These tears initiate during solidification of the alloy and may run through the entire ingot. To study the hot tearing mechanism, tensile tests were carried out in semisolid state and at low strain rates, and crack propagation was studied in situ by scanning electron microscopy (SEM). These experimentally induced cracks were compared with hot tears developed in an AA5182 ingot during a casting trial in an industrial research facility. Similarities in the microstructure of the tensile test specimens and the hot tears indicate that hot tearing can be simulated by performing tensile tests at semisolid temperatures. The experimental data were compared with existing hot tearing models and it was concluded that the latter are restricted to relatively high liquid fractions because they do not take into account the existence of solid bridges in the crack.
Aspergillus fumigatus colonization of punctal plugs.
Tabbara, Khalid F
2007-01-01
Punctal plugs are used in patients with dry eye syndrome to preserve the tears. In this report, I present two cases of Aspergillus fumigatus colonization of punctal plugs. Observational series of two cases. Approval was obtained from the institutional review board. Two men aged 29 and 31 years developed black spots inside the hole of punctal plug, which looked like eyeliner deposits. The deposits inside the hole of the plug in each patient were removed and cultured. Cultures of the two punctal plugs black deposits grew A fumigatus. Bacterial cultures were negative. Colonization of the punctal plug hole with A fumigatus was observed in two cases. It is recommended that punctal plugs be removed in patients undergoing refractive or intraocular procedures or in patients who are receiving topical corticosteroids. Current punctal plugs should be redesigned to avoid the presence of an inserter hole.
Avulsion of the anterior medial meniscus root: case report and surgical technique.
Feucht, Matthias J; Minzlaff, Philipp; Saier, Tim; Lenich, Andreas; Imhoff, Andreas B; Hinterwimmer, Stefan
2015-01-01
Injuries of the meniscus roots have become increasingly recognised as a serious pathology of the knee joint. However, the current available literature focuses primarily on posterior meniscus root tears. In this article, a case with an isolated avulsion of the anterior medial meniscus root is presented, and a new arthroscopic technique to treat this type of injury is described. The anterior horn of the medial meniscus was sutured with a double-looped nonabsorbable suture and reattached to the tibial plateau using a knotless suture anchor. This technique may also be useful to treat avulsion injuries of the anterolateral or posteromedial meniscus root, and symptomatic subluxation of the medial meniscus in case of a variant insertion anatomy with an absent attachment of the anterior horn of the medial meniscus to the tibial plateau. Level of evidence V.
Xiong, Ding-Bang; Cao, Mu; Guo, Qiang; Tan, Zhanqiu; Fan, Genlian; Li, Zhiqiang; Zhang, Di
2015-07-28
Metals can be strengthened by adding hard reinforcements, but such strategy usually compromises ductility and toughness. Natural nacre consists of hard and soft phases organized in a regular "brick-and-mortar" structure and exhibits a superior combination of mechanical strength and toughness, which is an attractive model for strengthening and toughening artificial composites, but such bioinspired metal matrix composite has yet to be made. Here we prepared nacre-like reduced graphene oxide (RGrO) reinforced Cu matrix composite based on a preform impregnation process, by which two-dimensional RGrO was used as "brick" and inserted into "□-and-mortar" ordered porous Cu preform (the symbol "□" means the absence of "brick"), followed by compacting. This process realized uniform dispersion and alignment of RGrO in Cu matrix simultaneously. The RGrO-and-Cu artificial nacres exhibited simultaneous enhancement on yield strength and ductility as well as increased modulus, attributed to RGrO strengthening, effective crack deflection and a possible combined failure mode of RGrO. The artificial nacres also showed significantly higher strengthening efficiency than other conventional Cu matrix composites, which might be related to the alignment of RGrO.
NASA Astrophysics Data System (ADS)
Gajda, Jerzy K.; Niesterowicz, Andrzej; Mazurkiewicz, Henryk
1995-03-01
A high number of osseous diseases, particularly of the backbone and hip-joint regions, result in a need for their overall treatment and prevention. Two basic treatment methods are used: physical exercises at an early stage of the illness, and surgical treatment in an advanced stage. Recently, in operational treatment of coxarthrosis the elements of the joint (acetabulum and capitellum) were replaced by their artificial counterparts, despite some drawbacks and unknowns related to this kind of treatment. In order to check the effectiveness of this treatment and to eliminate its drawbacks we have tested the joint by means of speckle photography method. The objective of this paper is an attempt to evaluate stress and displacement distributions in a system consisting of artificial acetabulum and capitellum and a natural bone in order to determine an optimum fitting of artificial acetabulum and capitellum and a natural bone in order to determine an optimum fitting of artificial elements that guarantees uniform distribution of stresses corresponding to anatomical and physiological parameters of the hip-joint. Speckle photographs have been analyzed point by point with the help of the algorithm for striped images processing.
CT arthrography of capsular structures of the shoulder.
Rafii, M; Firooznia, H; Golimbu, C; Minkoff, J; Bonamo, J
1986-02-01
The capsular mechanism of the shoulder joint consists of the joint capsule, which is strengthened by the glenohumeral ligaments and the rotator cuff, the glenoid labrum, and a variable number of synovial recesses. Although the fibrous capsule is a lax structure, the normal function of the capsular mechanism makes it an effective barrier against anterior dislocation, particularly in external rotation. There has been a tendency in the past to overestimate the role of the glenoid labrum in stability of the shoulder joint. In patients with instability, the significance of the capsular attachment or its anomalous insertions to the glenoid has not been adequately recognized. Labral tears may develop as secondary lesions due to repeated dislocations and subluxations rather than representing the primary lesion responsible for instability. Operative visualization of capsular defects or detachments is often difficult. Prior knowledge of these lesions can effectively help the choice of an appropriate surgical procedure and reduce operating time. The results of computed tomographic (CT) arthrography of the shoulder joint in 45 patients are reported and the normal and pathologic variations of the joint capsule and particularly the capsular insertions are described. Configuration of the joint recesses and the glenoid labrum are also evaluated. These CT findings were correlated and verified by surgery or arthroscopy in 26 cases.
Groin Injuries (Athletic Pubalgia) and Return to Play
Elattar, Osama; Choi, Ho-Rim; Dills, Vickie D.; Busconi, Brian
2016-01-01
Context: Groin pain is a common entity in athletes involved in sports that require acute cutting, pivoting, or kicking such as soccer and ice hockey. Athletic pubalgia is increasingly recognized as a common cause of chronic groin and adductor pain in athletes. It is considered an overuse injury predisposing to disruption of the rectus tendon insertion to the pubis and weakness of the posterior inguinal wall without a clinically detectable hernia. These patients often require surgical therapy after failure of nonoperative measures. A variety of surgical options have been used, and most patients improve and return to high-level competition. Evidence Acquisition: PubMed databases were searched to identify relevant scientific and review articles from January 1920 to January 2015 using the search terms groin pain, sports hernia, athletic pubalgia, adductor strain, osteitis pubis, stress fractures, femoroacetabular impingement, and labral tears. Study Design: Clinical review. Level of Evidence: Level 4. Results and Conclusion: Athletic pubalgia is an overuse injury involving a weakness in the rectus abdominis insertion or posterior inguinal wall of the lower abdomen caused by acute or repetitive injury of the structure. A variety of surgical options have been reported with successful outcomes, with high rates of return to the sport in the majority of cases. PMID:27302153
A mass and solute balance model for tear volume and osmolarity in the normal and the dry eye.
Gaffney, E A; Tiffany, J M; Yokoi, N; Bron, A J
2010-01-01
Tear hyperosmolarity is thought to play a key role in the mechanism of dry eye, a common symptomatic condition accompanied by visual disturbance, tear film instability, inflammation and damage to the ocular surface. We have constructed a model for the mass and solute balance of the tears, with parameter estimation based on extensive data from the literature which permits the influence of tear evaporation, lacrimal flux and blink rate on tear osmolarity to be explored. In particular the nature of compensatory events has been estimated in aqueous-deficient (ADDE) and evaporative (EDE) dry eye. The model reproduces observed osmolarities of the tear meniscus for the healthy eye and predicts a higher concentration in the tear film than meniscus in normal and dry eye states. The differential is small in the normal eye, but is significantly increased in dry eye, especially for the simultaneous presence of high meniscus concentration and low meniscus radius. This may influence the interpretation of osmolarity values obtained from meniscus samples since they need not fully reflect potential damage to the ocular surface caused by tear film hyperosmolarity. Interrogation of the model suggests that increases in blink rate may play a limited role in compensating for a rise in tear osmolarity in ADDE but that an increase in lacrimal flux, together with an increase in blink rate, may delay the development of hyperosmolarity in EDE. Nonetheless, it is predicted that tear osmolarity may rise to much higher levels in EDE than ADDE before the onset of tear film breakup, in the absence of events at the ocular surface which would independently compromise tear film stability. Differences in the predicted responses of the pre-ocular tears in ADDE compared to EDE or hybrid disease to defined conditions suggest that no single, empirically-accessible variable can act as a surrogate for tear film concentration and the potential for ocular surface damage. This emphasises the need to measure and integrate multiple diagnostic indicators to determine outcomes and prognosis. Modelling predictions in addition show that further studies concerning the possibility of a high lacrimal flux phenotype in EDE are likely to be profitable.
Shi, Yue; Zhu, Minjia; Chang, Yu; Qiao, Huanyu; Liu, Yongmin
2016-12-28
This study is to investigate the influence of hemodynamics on Stanford type-A aortic dissection with different tear size and location, to provide some support for the relationships between the risks (rupture, reverse tearing and further tearing) and tear size and location for clinical treatment. Four numerical models of Stanford type-A aortic dissection were established, with different size and location of the tears. The ratio of the area between the entry and re-entry tears(RA) is various within the model; while, the size and the location of the re-entry in the distal descending aorta are fixed. In model A11 and A21, the entry tears are located near the ascending aorta. The RA in these models are 1 and 2, respectively; In the model B11 and B21, the entry tears are located near the proximal descending aorta and the RA in these models are again assigned to 1 and 2, respectively. Then hemodynamics in these models was solved with numerically and the flow patterns and loading distributions were investigated. The flow velocity of the true lumen in model A21, B21 is lower than that in A11, B11, respectively; the time-averaged wall shear stress (TAWSS) of the false lumen in model A21 and B21 is higher, and for ascending aorta false lumen, A11, A21 are higher than B11, B21, respectively. False lumen intimal wall pressure of A11, A21 are always higher than the true lumen ones. The variation of the RA can significantly affect the dynamics of blood within the aortic dissection. When the entry tear size is larger than the re-entry tear ones, the false lumen, proximal descending aorta and the wall near re-entry tear are prone to cracking. Entry tear location can significantly alter the hemodynamics of aortic dissection as well. When entry tear location is closer to proximal ascending aorta, false lumen continues to expand and compress the true lumen resulting in the true lumen reduction. For proximal ascending aorta, high pressure in false lumen predicts a higher risk of reverse tear.
Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny
2013-12-23
To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.
The Relationship between Metabolic Syndrome, Its Components, and Dry Eye: A Cross-Sectional Study.
Erdur, Sevil Karaman; Aydin, Rukiye; Ozsutcu, Mustafa; Olmuscelik, Oktay; Eliacik, Mustafa; Demirci, Goktug; Kocabora, Mehmet Selim
2017-08-01
The aim of this study was to evaluate tear osmolarity and tear film function and ocular surface changes in patients with metabolic syndrome. 108 eyes of 64 patients with metabolic syndrome (group 1) and 110 eyes of 55 healthy individuals (group 2) were included in this cross-sectional study. All participants were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity. Main outcome measures were Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT), and tear osmolarity values. Tear osmolarity values and OSDI scores were significantly higher in group 1 (314.4 ± 19.1 mOsm and 38.9 ± 1.1, respectively) compared with group 2 (295 ± 14.3 mOsm and 18.69 ± 17.2, respectively) (p = 0.01 for both). The Schirmer test values and TBUT in group 1 (10 ± 3.7 mm and 14.8 ± 3.6 sec, respectively) were significantly lower compared with group 2 (16.8 ± 2.6 mm and 18.1 ± 0.5 sec, respectively) (p < 0.001 for both). There was significant correlation between tear osmolarity versus waist circumference and fasting blood glucose in the study group (r = 0.364, p = 0.04; and r = 0.542, p ≤ 0.001, respectively). This study showed that metabolic syndrome can influence tear osmolarity and tear film function. Patients with metabolic syndrome showed tear hyperosmolarity and tear film dysfunction.
Subregional effects of meniscal tears on cartilage loss over 2 years in knee osteoarthritis.
Chang, Alison; Moisio, Kirsten; Chmiel, Joan S; Eckstein, Felix; Guermazi, Ali; Almagor, Orit; Cahue, September; Wirth, Wolfgang; Prasad, Pottumarthi; Sharma, Leena
2011-01-01
Meniscal tears have been linked to knee osteoarthritis progression, presumably by impaired load attenuation. How meniscal tears affect osteoarthritis is unclear; subregional examination may help to elucidate whether the impact is local. This study examined the association between a tear within a specific meniscal segment and subsequent 2-year cartilage loss in subregions that the torn segment overlies. Participants with knee osteoarthritis underwent bilateral knee MRI at baseline and 2 years. Mean cartilage thickness within each subregion was quantified. Logistic regression with generalised estimating equations were used to analyse the relationship between baseline meniscal tear in each segment and baseline to 2-year cartilage loss in each subregion, adjusting for age, gender, body mass index, tear in the other two segments and extrusion. 261 knees were studied in 159 individuals. Medial meniscal body tear was associated with cartilage loss in external subregions and in central and anterior tibial subregions, and posterior horn tear specifically with posterior tibial subregion loss; these relationships were independent of tears in the other segments and persisted in tibial subregions after adjustment for extrusion. Lateral meniscal body and posterior horn tear were also associated with cartilage loss in underlying subregions but not after adjustment for extrusion. Cartilage loss in the internal subregions, not covered by the menisci, was not associated with meniscal tear in any segment. These results suggest that the detrimental effect of meniscal tears is not spatially uniform across the tibial and femoral cartilage surfaces and that some of the effect is experienced locally.
Complete vs partial-thickness tears of the posterior cruciate ligament: MR findings.
Patten, R M; Richardson, M L; Zink-Brody, G; Rolfe, B A
1994-01-01
We sought to define the MRI appearance of both complete and partial-thickness tears of the posterior cruciate ligament (PCL) and to describe patterns of injury and associated MRI findings. Three radiologists retrospectively reviewed MR images and medical records on 32 patients with PCL tears (15 complete, 17 partial) and correlated MRI findings to results of clinical testing and surgery. The PCL had indistinct margins in 27 (84%) of 32 patients and was abnormally thick in 25 (78%) patients. In 31 (97%) patients, the torn PCL showed increased signal intensity on both T1- and T2-weighted pulse sequences. Although there was no statistically significant difference between patients with complete tears and those with partial tears with regard to thickness, margination, and signal intensity of the PCL, MR images in patients with complete tears were more likely to show focal areas of ligamentous discontinuity (10 of 15 cases) (p = 0.01). Associated knee injuries were seen in 21 (66%) patients and were seen more frequently in patients with complete PCL tears (p = 0.015). Bony injury (n = 11, 34%) and tears of the medial collateral ligament (n = 13, 41%) and menisci (n = 10, 31%) were common. No specific pattern of bony injury was found. Posterior cruciate ligament tears can be diagnosed readily by multiplanar MRI using both morphological and signal intensity characteristics. Although differentiation between complete and partial-thickness PCL tears by MRI criteria alone is more problematic, complete tears are more likely to show focal areas of discontinuity and partial tears are more likely to show at least some intact fibers.
Age-related changes in the signal value of tears.
Zeifman, Debra M; Brown, Sarah A
2011-08-12
Emotional tears may be uniquely human and are an effective signal of distress in adults. The present study explored whether tears signal distress in younger criers and whether the effect of tears on observers is similar in magnitude across the life span. Participants rated photographs of crying infants, young children, and adults, with tears digitally removed or added. The effectiveness of tears in conveying sadness and eliciting sympathy was greatest for images of adults, intermediate for images of children, and least potent for images of infants. These findings suggest that the signal value of tears varies with the age of the crier. The results may shed light on the functional significance of crying at different stages of human development.
Relationship of Tear Size and Location to Fatty Degeneration of the Rotator Cuff
Kim, H. Mike; Dahiya, Nirvikar; Teefey, Sharlene A.; Keener, Jay D.; Galatz, Leesa M.; Yamaguchi, Ken
2010-01-01
Background: Fatty degeneration of the rotator cuff muscles may have detrimental effects on both anatomical and functional outcomes following shoulder surgery. The purpose of this study was to investigate the relationship between tear geometry and muscle fatty degeneration in shoulders with a deficient rotator cuff. Methods: Ultrasonograms of both shoulders of 262 patients were reviewed to assess the type of rotator cuff tear and fatty degeneration in the supraspinatus and infraspinatus muscles. The 251 shoulders with a full-thickness tear underwent further evaluation for tear size and location. The relationship of tear size and location to fatty degeneration of the supraspinatus and infraspinatus muscles was investigated with use of statistical comparisons and regression models. Results: Fatty degeneration was found almost exclusively in shoulders with a full-thickness rotator cuff tear. Of the 251 shoulders with a full-thickness tear, eighty-seven (34.7%) had fatty degeneration in either the supraspinatus or infraspinatus, or both. Eighty-two (32.7%) of the 251 full-thickness tears had a distance of 0 mm between the biceps tendon and anterior margin of the tear. Ninety percent of the full-thickness tears with fatty degeneration in both muscles had a distance of 0 mm posterior from the biceps, whereas only 9% of those without fatty degeneration had a distance of 0 mm. Tears with fatty degeneration had significantly greater width and length than those without fatty degeneration (p < 0.0001). Tears with fatty degeneration had a significantly shorter distance posterior from the biceps than those without fatty degeneration (p < 0.0001). The distance posterior from the biceps was found to be the most important predictor for supraspinatus fatty degeneration, whereas tear width and length were found to be the most important predictors for infraspinatus fatty degeneration. Conclusions: Fatty degeneration of the rotator cuff muscles is closely associated with tear size and location. The finding of this study suggests that the integrity of the anterior supraspinatus tendon is important to the development of fatty degeneration. Patients with full-thickness tears that extend through this area may benefit from earlier surgical intervention if fatty degeneration has not already occurred. Additionally, the findings suggest the importance of secure fixation and healing of the anterior aspect of the supraspinatus with surgical repair. PMID:20360505
Radial tears associated with cleavage tears of the medial meniscus in athletes.
Kidron, Amos; Thein, Rafael
2002-03-01
To evaluate the significance of a small radial tear in the root of the posterior horn of the medial meniscus in an otherwise normal-looking meniscus in individuals who play vigorous sports. Retrospective review. Arthroscopy was performed in 1,270 patients; 11 patients (0.86%) had a small radial tear in the root of the medial meniscus. Trimming of the tear revealed a large horizontal cleavage tear of the posterior horn and body of the meniscus. The average age of the affected patients was 29.6 years (range, 21 to 45 years), and all were active in sports. Magnetic resonance imaging was of dubious diagnostic value. Three patients had undergone previous arthroscopy at which time the small radial root tear had been noted but was not thought to warrant treatment. All 11 patients returned to their former levels of activity after adequate surgery. When a radial root tear in the medial meniscus is found in an athletic patient, the edges of the tear should be trimmed, the root of the medial meniscus examined, and any additional torn cartilage resected.
Patterns of meniscal tears associated with anterior cruciate ligament lesions in athletes.
Binfield, P M; Maffulli, N; King, J B
1993-09-01
In this study, 400 clinically anterior cruciate ligament (ACL) deficient knees were arthroscoped and studied prospectively in the period January 1986 to April 1992. An ACL tear was always confirmed, and 41 per cent of these patients did not have an associated meniscal tear. In 30.25 per cent the lateral meniscus was torn; in 21.25 per cent the ACL tear was associated with a medial meniscus tear, and in the remaining 7 per cent both menisci were torn. The most frequently associated meniscal injury was the bucket handle tear of the medial meniscus (9 per cent), followed by the posterior horn tear of the lateral meniscus, which showed the same frequency as the ragged (or degenerated) tear of the lateral meniscus (6 per cent). The horizontal tear of the posterior part of the lateral meniscus showed a prevalence of 4.3 per cent. This picture is probably dependent on a secondary referral nature of the centre surveyed, in which the average time between injury and arthroscopy was 23.3 months.
Zhang, Luyan; Sun, Xiyu; Yu, Ye; Xiong, Yan; Cui, Yuxin; Wang, Qinmei; Hu, Liang
2016-01-01
To investigate the correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK (FS-LASIK) surgery. In this prospective clinical study, 31 patients undergoing FS-LASIK for myopia were recruited. The upper and lower tear meniscus volumes (UTMV and LTMV) were measured by customized anterior segment optical coherence tomography, tear film osmolarity was measured by a TearLab Osmolarity test device, central corneal sensation was measured by a Cochet-Bonner esthesiometer preoperatively, at 1 week, 1 and 3 months postoperatively. Repeated measures analysis of variance was used to evaluate whether the tear film osmolarity, tear meniscus volume, and corneal sensation were changed after surgery. The correlations between these variables were analyzed by the Pearson correlation analysis. The tear film osmolarity was (310.03 ± 16.48) mOsms/L preoperatively, (323.51 ± 15.92) mOsms/L at 1 week, (319.93 ± 14.27) mOsms/L at 1 month, and (314.97±12.91) mOsms/L at 3 months. The UTMV was (0.42±0.15), (0.25± 0.09), (0.30±0.11), and (0.35±0.09) μL, respectively; the LTMV was (0.60±0.21),(0.37±0.08), (0.44± 0.14), and (0.52±0.17) μL, respectively. The tear film osmolarity was significantly higher at 1 week and 1 month postoperatively compared with the baseline (P=0.001, 0.004), and reduced to the preoperative level at 3 months (P=0.573). The UTMV, LTMV, and corneal sensation values presented significant decreases at all postoperative time points (all P<0.05). The Pearson correlation analysis showed the postoperative UTMV had a weak relationship with corneal sensation at 1 week after surgery (r=0.356,P=0.005). There were significant correlations between the preoperative LTMV and corneal sensation at 1 week, 1 and 3 months (respectively, r=0.422, 0.366, 0.352;P=0.001, 0.004, 0.006). No significant correlations were found between the tear film osmolarity, tear meniscus volume, and corneal sensation after surgery (all P>0.05). The tear film osmolarity, tear meniscus volume, and corneal sensation became aggravated due to the FS-LASIK surgery procedures. There were significant correlations between the preoperative tear meniscus volume and recovery of corneal sensation early after surgery. A higher tear meniscus volume before surgery may contribute to a faster corneal sensation recovery.
Status of the contralateral rotator cuff in patients undergoing rotator cuff repair.
Ro, Kyung-Han; Park, Jong-Hoon; Lee, Soon-Hyuck; Song, Dong-Ik; Jeong, Ha-Joon; Jeong, Woong-Kyo
2015-05-01
Although the prevalence of rotator cuff tear (RCT) in the general population has been analyzed, little information is available on the status of the opposite-side rotator cuff in patients who have undergone arthroscopic rotator cuff repair. To identify the characteristics of the contralateral shoulder and to identify factors associated with RCT of the contralateral shoulder in patients who underwent surgery for symptomatic RCT. The hypothesis was that the prevalence of RCT in the contralateral shoulder would be higher in patients with increasingly larger cuff tears requiring surgical intervention. Case series; Level of evidence, 4. The study cohort consisted of 140 patients with RCT who underwent arthroscopic rotator cuff repair. Opposite-shoulder rotator cuff tendons of all patients were evaluated by ultrasonography. Demographic information and factors related to contralateral RCT were investigated, and risk factors associated with contralateral RCT were assessed. Of the 140 patients who underwent arthroscopic rotator cuff repair, 54 (38.6%) had an RCT of the contralateral shoulder. Of 51 patients with partial-thickness and small-sized full-thickness tears of the operated shoulder, 35 (68.6%) had no tears; 14 (27.5%) had partial-thickness tears; and 2 (3.9%) had small-sized full-thickness tears of the contralateral shoulder. Of 75 patients with medium-sized full-thickness tears, 43 (57.3%) had no tears; 12 (16%) had partial-thickness tears; and 20 (26.7%) had full-thickness tears of the contralateral shoulder. Of 14 patients with large to massive full-thickness tears, 8 (57.1%) had no tears; 1 (7.1%) had a partial-thickness tear; and 5 (35.7%) had full-thickness tears of the contralateral shoulder. The prevalence of RCT of the contralateral shoulder differed significantly among groups classified by tear size (P=.007). The mean American Shoulder and Elbow Surgeons score was significantly lower in the RCT than in the nontear group (55.8±16.9 vs 61.6±13.3; P=.03). Of 29 subjects with symptomatic tears involving the nondominant arm, 17 (58.6%) had contralateral asymptomatic RCT, compared with 37 of 111 (33.3%) subjects with symptomatic tears involving the dominant arm (P=.007). The prevalence of RCT of the contralateral asymptomatic shoulder tends to be higher in patients with more symptomatic RCT on one side, in patients with medium-sized or larger RCT in the operated shoulder, and in patients with symptomatic RCT in the nondominant arm. © 2015 The Author(s).
Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.
Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao
2017-12-01
The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.
Combination therapy for male erectile dysfunction and urinary incontinence.
Zafirakis, Helen; Wang, Run; Westney, O Lenaine
2008-01-01
Urinary incontinence (UI) and erectile dysfunction (ED) are both very prevalent conditions. Insertion of an artificial urinary sphincter (AUS) and penile prosthesis (PP) is an effective and proven method of treatment for both conditions. With advancing age, as well as with increasing populations of patients radically treated for prostate cancer, the occurrence of both conditions found in the same patient is increasing. The purpose of this article was to analyze the available evidence for simultaneous surgical management of male ED and UI using prosthetic devices. The existing literature pertaining to dual implantation of AUS and PP was reviewed. The concomitant insertion of the PP with the male perineal sling was also considered. Concurrent ED and UI are increasingly seen in the post radical prostatectomy population, who are often younger and less willing to suffer with these conditions. Insertion of an AUS and PP, either simultaneously or as a two-stage procedure, appears to be a safe, efficacious and long-lasting method of treatment. The improvements in design of both the AUS and PP as well as the development of the single transverse scrotal incision have made simultaneous insertion of these prostheses possible. Dual implantation of the PP and male sling looks promising in a selected population. In conclusion, the insertion of the AUS and PP for the treatment of concurrent UI and ED is safe and effective. Simultaneous insertion of these prostheses in the same patient offers potential advantages in operative and recovery time and is associated with high patient satisfaction. Combination therapy should therefore be included in the arsenal of treatment of these conditions.
Response of Metals and Metallic Structures to Dynamic Loading
1978-05-01
materials for service by testing under high rates of loading. Impact tests such as the Charpy test, the drop-weight tear test, and the dynamic tear...have clearly shown this for precracked charpy specimens and for the drop-weight tear test. Hence, there is a strong need for additional dynamic...dynamic fracture resistance ( Charpy , dynamic-tear, drop-weight tear test, etc.), normally assures that fracture in dynamically loaded structures is
Interferometer for measuring the dynamic surface topography of a human tear film
NASA Astrophysics Data System (ADS)
Primeau, Brian C.; Greivenkamp, John E.
2012-03-01
The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. Following a blink, the tear film quickly smoothes and starts to become irregular after 10 seconds. This irregularity can affect comfort and vision quality. An in vivo method of characterizing dynamic tear films has been designed based upon a near-infrared phase-shifting interferometer. This interferometer continuously measures light reflected from the tear film, allowing sub-micron analysis of the dynamic surface topography. Movies showing the tear film behavior can be generated along with quantitative metrics describing changes in the tear film surface. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or corneal topography and provides better sensitivity and resolution than shearing interferometry methods. The interferometer design is capable of identifying features in the tear film much less than a micron in height with a spatial resolution of about ten microns over a 6 mm diameter. This paper presents the design of the tear film interferometer along with the considerations that must be taken when designing an interferometer for on-eye diagnostics. Discussions include eye movement, design of null optics for a range of ocular geometries, and laser emission limits for on-eye interferometry.
Yoon, Jin Sook; Choi, Soo Hyun; Lee, Joon H; Lee, Sung Jun; Lee, Sang Yeul
2010-02-01
To measure tear nerve growth factor (NGF) concentrations in cases of active thyroid-associated ophthalmopathy (TAO) before and after glucocorticoid treatment, and to correlate NGF levels with disease inflammatory activity and thyroid autoantibody concentration. The study involved 20 patients with active TAO and 20 age- and gender-matched controls. Tear break-up time (BUT) was obtained, the Schirmer test was performed, and tear NGF/total protein ratio was measured in control subjects and patients with active TAO before, and 2 and 4 weeks after, steroid treatment. Tear BUT and Schirmer values significantly increased after 2 and 4 weeks of steroid treatment (p < 0.001 and p = 0.004 respectively). Baseline tear NGF/total protein ratio was higher in patients with active TAO than in control subjects, and the ratio significantly decreased after 2 and 4 weeks of steroid treatment (p < 0.001). Tear NGF/total protein ratio did not correlate with inflammatory activity score, exophthalmos value and thyroid binding inhibiting immunoglobulin (TBII) level (p > 0.05). Tear NGF may have a specific role in ocular surface inflammation, which protects against ocular surface damage in patients with active TAO. Anti-inflammatory treatment significantly reduced the level of NGF in tears, increased tear film stability and production, and decreased congestive symptoms.
Choi, Eui-Sung; Park, Sang-Jun
2015-06-01
To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn.
Maffulli, Nicola; Longo, Umile Giuseppe; Maffulli, Gayle D; Rabitti, Carla; Khanna, Anil; Denaro, Vincenzo
2011-04-01
A laboratory study was performed to evaluate the histopathological features of the macroscopically intact portion of the Achilles tendon in patients undergoing surgery for an acute rupture of the Achilles tendon. Tendon samples were harvested from 29 individuals (21 men, 8 women; mean age: 46 ± 12) who underwent repair of an Achilles tendon tear tear, and from 11 male patients who died of cardiovascular events (mean age: 61). Three pieces of tendon were harvested: at the rupture site, 4 cm proximal to the site of rupture, 1 cm proximal to the insertion of the Achilles tendon on the calcaneum. Slides were assessed using a semiquantitative grading scale assessing fiber structure and arrangement, rounding of the nuclei, regional variations in cellularity, increased vascularity, decreased collagen stainability, and hyalinization. Intra-observer reliability of the subscore readings was calculated. The pathological features were significantly more pronounced in the samples taken from the site of rupture than in the samples taken proximally and distal to it (0.008 < P < 0.01). There were no significant differences in the mean pathologic sum-scores in the samples taken proximally and distal to the site of rupture. Unruptured Achilles tendons, even at an advanced age, and ruptured Achilles tendons are clearly part of two distinct populations, with the latter demonstrating histopathological evidence of failed healing response even in areas macroscopically normal.
Nanocarriers in ocular drug delivery: an update review.
Wadhwa, Sheetu; Paliwal, Rishi; Paliwal, Shivani Rai; Vyas, S P
2009-01-01
Controlled drug delivery to eye is one of the most challenging fields of pharmaceutical research. Low drug-contact time and poor ocular bioavailability due to drainage of solution, tear turnover and its dilution or lacrimation are the problems associated with conventional systems. In addition, anatomical barriers and physiological conditions of eye are also important parameters which control designing of drug delivery systems. Nanosized carriers like micro/nano-suspensions, liposome, niosome, dendrimer, nanoparticles, ocular inserts, implants, hydrogels and prodrug approaches have been developed for this purpose. These novel systems offer manifold advantages over conventional systems as they increase the efficiency of drug delivery by improving the release profile and also reduce drug toxicity. Conventional delivery systems get diluted with tear, washed away through the lacrimal gland and usually require administering at regular time intervals whereas nanocarriers release drug at constant rate for a prolonged period of time and thus enhance its absorption and site specific delivery. This review presents an overview of the various aspects of the ocular drug delivery, with special emphasis on nanocarrier based strategies, including structure of eye, its barriers, delivery routes and the challenges/limitations associated with development of novel nanocarriers. The recent progresses in therapy of ocular disease like gene therapy have also been included so that future options should also be considered from the delivery point of view. Recent progress in the delivery of proteins and peptides via ocular route has also been incorporated for reader benefit.
Reduced tear production in three canine endocrinopathies.
Williams, D L; Pierce, V; Mellor, P; Heath, M F
2007-05-01
Previous reports have suggested that hypothyroid and diabetic patients can be predisposed to keratoconjunctivitis sicca. This study aimed to measure tear production in dogs with diabetes, hypothyroidism and hyperadrenocorticism using the Schirmer tear test and to compare these results with Schirmer tear test values for a group of normal dogs. Schirmer tear tests were performed on 16 dogs with hyperadrenocorticism, 18 with diabetes and 12 with hypothyroidism together with 100 control dogs. Corneal sensitivity was also measured in 12 of the 18 diabetic dogs with a Cochet Bonnet aesthesiometer and compared with age- and breed-matched normal dogs. Schirmer tear test values in dogs with hypothyroidism, hyperadrenocorticism and diabetes were 12.3+/-3.2, 14.0+/-4.0 and 12.3+/-5.3 mm/minutes, respectively. Schirmer tear test values were significantly lower than that for the control group (19.6+/-4.2 mm/minutes) in all dogs with an endocrinopathy. Only in two hypothyroid dogs and three diabetics, this was manifested as profound keratoconjunctivitis sicca with Schirmer tear test value lower than 5 mm/minutes. Diabetic dogs had significantly reduced corneal sensitivity compared with a matched set of control dogs. This study shows a significant reduction in tear production in animals with diabetes mellitus, hypothyroidism and hyperadrenocorticism. Further research is needed to elucidate the mechanisms by which this reduction in tear production occurs. Assessment of tear production should be undertaken in animals diagnosed with these endocrinopathies, as these animals may progress to clinical keratoconjunctivitis sicca.
Dry eye symptoms are increased in mice deficient in phospholipid transfer protein (PLTP).
Setälä, Niko L; Metso, Jari; Jauhiainen, Matti; Sajantila, Antti; Holopainen, Juha M
2011-05-01
In the tear fluid the outermost part facing the tear-air interface is composed of lipids preventing evaporation of the tears. Phospholipid transfer protein (PLTP) mediates phospholipid transfer processes between serum lipoproteins and is also a normal component of human tears. To study whether PLTP plays any functional role in tear fluid we investigated PLTP-deficient mice, applying functional and morphologic analyses under normal housing and experimentally induced dry eye conditions. Aqueous tear fluid production, corneal epithelial morphology, barrier function, and occludin expression were assessed. In mice with a full deficiency of functional PLTP enhanced corneal epithelial damage, increased corneal permeability to carboxyfluorescein, and decreased corneal epithelial occludin expression were shown. These pathologic signs were worsened by experimentally induced dry eye both in wild-type and PLTP knock-out mice. Deficiency in the production of tear PLTP in mice is accompanied by corneal epithelial damage, a feature that is typical in human dry eye syndrome (DES). To complement animal experiments we collected tear fluid from human dry eye patients as well as healthy control subjects. Increased tear fluid PLTP activity was observed among DES patients. In conclusion, the presence of PLTP in tear fluid appears to be essential for maintaining a healthy and functional ocular surface. Increased PLTP activity in human tear fluid in DES patients suggests an ocular surface protective role for this lipid transfer protein. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Diadenosine tetraphosphate contributes to carbachol-induced tear secretion.
Fonseca, Begoña; Martínez-Águila, Alejandro; Díaz-Hernández, Miguel; Pintor, Jesús
2015-03-01
The purpose of this study is to investigate if the cholinergic stimulation by carbachol on tear secretion is a direct process or if it is also mediated by purinergic mechanisms. Experiments were performed in New Zealand male rabbits. The amount of tear secretion was measured with Schirmer's test and then analyzed by a HPLC protocol in order to study the nucleotide levels. Animal eyes were instilled with carbachol (a cholinergic agonist), pirenzepine, gallamine and 4-DAMP (muscarinic antagonists), PPADS, suramin and reactive blue 2 (purinergic antagonists), and a P2Y2 receptor small interfering RNA (siRNA). Tear secretion increased with the instillation of carbachol, approximately 84 % over control values 20 min after the instillation and so did Ap4A and ATP release. When we applied carbachol in the presence of muscarinic antagonists, tear volume only increased to 4 % with atropine, 12 % in the case of pirenzepine, 3 % with gallamine, and 8 % with 4-DAMP. In the presence of carbachol and purinergic antagonists, tear secretion was increased to 12 % (all values compared to basal tear secretion). By analyzing tear secretion induced with carbachol in presence of a P2Y2 receptor siRNA, we found that tear secretion was diminished to 60 %. The inhibition of tear secretion in the presence of carbachol and purinergic antagonists or P2Y2 siRNA occurred with no apparent change in the tear amount of Ap4A. These experiments demonstrated the participation of Ap4A in lacrimal secretion process.
Evaluation of cartilage degeneration in a rat model of rotator cuff tear arthropathy
Kramer, Erik J.; Bodendorfer, Blake M.; Laron, Dominique; Wong, Jason; Kim, Hubert T.; Liu, Xuhui; Feeley, Brian T.
2013-01-01
Introduction Rotator cuff tears are the most common injury seen by shoulder surgeons. Many late stage rotator cuff tear patients develop glenohumeral osteoarthritis as a result of torn cuff tendons, termed cuff tear arthropathy. However, the mechanisms of cuff tear arthropathy have not been fully established. It has been hypothesized that a combination of synovial and mechanical factors contribute equally to the development of cuff tear arthropathy. The goal of this study was to assess the utility of this model in investigating cuff-tear arthropathy. Methods We utilized a rat model which accurately reflects rotator cuff muscle degradation after massive rotator cuff tears through either infraspinatus and supraspinatus tenotomy or suprascapular nerve transection. Using a Modified-Mankin Scoring System (MMS), we found significant glenohumeral cartilage damage following both rotator cuff tenotomy and suprascapular nerve transection after only 12 weeks. Results Cartilage degeneration was similar between groups, and was present on both the humeral head and the glenoid. Denervation of the supraspinatus and infraspinatus muscles without opening the joint capsule caused cartilage degeneration similar to that found in the tendon transection group. Conclusions These results suggest that altered mechanical loading after rotator cuff tears is the primary factor in cartilage degeneration after rotator cuff tears. Clinically, understanding the process of cartilage degeneration after rotator cuff injury will help guide treatment decisions in the setting of rotator cuff tears. Level of evidence Basic Science Study, Animal Model PMID:23664745
A review of patient and skin characteristics associated with skin tears.
Rayner, R; Carville, K; Leslie, G; Roberts, P
2015-09-01
Skin tears are the most common wound among the elderly and have the potential to cause infection, form chronic wounds, reduce quality of life and increase health-care costs. Our aim was to identify studies that reviewed patient and skin characteristics associated with skin tears. A review of skin tear studies reported in the English literature between 1980 and 2013 was undertaken using the following electronic databases: PubMed, Medline, CINAHL, Embase, Scopus, Evidence Based and Medicine Reviews (EBM). Search terms included aged, skin, tears or lacerations, skin tearing, geri tear, epidermal tear and prevalence. There were 343 articles found with using the search terms. After abstract review nine were found to be relevant to the search. The principle findings from these eight published articles and one unpublished study revealed that the most common patient characteristics were a history of skin tears, impaired mobility and impaired cognition. Skin characteristics associated with skin tears included senile purpura, ecchymosis and oedema. This review provides an overview of identified patient and skin characteristics that predispose the elderly to skin tears and exposes the lack of research within this domain. R. Rayner is a recipient of a 2013 Australian Postgraduate Award, Curtin University Postgraduate Scholarship and a Wound Management Cooperative Research Centre (CRC) PhD stipend. The School of Nursing, Midwifery and Paramedicine, Curtin University and the Silver Chain Group, Western Australia are participants in the Wound Management Innovation CRC. No conflict of interest exists among the authors.
Neurostimulation of the Lacrimal Nerve for Enhanced Tear Production
Kossler, Andrea L.; Wang, Jianhua; Feuer, William; Tse, David T.
2014-01-01
Purpose To design a proof-of-concept study to assess the effect of lacrimal nerve stimulation (LNS) with an implantable pulse generator (IPG) to increase aqueous tear production. Methods Experimental animal study design of six Dutch Belted rabbits. Ultra high-resolution optical coherence tomography (UHR-OCT) quantified tear production by measuring the baseline tear volume of each rabbit’s right and left eye. A neurostimulator was implanted adjacent to the right lacrimal nerve. After two minutes of LNS (100 μs, 1.6 mAmp, 20 Hz, 5–8 volts), the tear volumes were measured with UHR-OCT. The change in tear volume was quantified and compared to the non-stimulated left eye. Three rabbits underwent chronic LNS (100 μS, 1.6 mAmp, 10 Hz, 2 volts) and their lacrimal glands were harvested for histopathologic analysis. Results UHR-OCT imaging of the right eyes tear volume showed a 441% average increase in tear production after LNS as a percent of baseline. After stimulation, right eyes had statistically significant greater increase in tear volumes than left eyes (p=0.028, Wilcoxon test). Post-stimulation right eye tear volumes were significantly greater compared to baseline (p=0.028, Wilcoxon test). Histopathologic examination of the lacrimal glands showed no discernible tissue damage from chronic neurostimulation. Additionally, there were no gross adverse effects on the general well-beings of the animals due to chronic stimulation. Conclusions Lacrimal nerve stimulation with an implantable pulse generator appears to increase aqueous tear production. Chronic LNS showed no histopathologic lacrimal gland damage. This study suggests LNS is a promising new treatment strategy to increase aqueous tear production. PMID:25126767
Ham, Bryan M.; Cole, Richard B.; Jacob, Jean T.
2008-01-01
Purpose To identify and compare the phosphorylated lipids in normal and dry eye rabbit tears using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Methods MALDI-TOF MS studies were performed on tear samples from normal and dry eyes of female New Zealand White rabbits. Experimental dry eye was induced by complete removal of the main and accessory lacrimal glands and nictitating membranes. A solid ionic crystal MALDI matrix of paranitroaniline and butyric acid was used to enhance the mass spectral responses of the phospholipids. In addition, a novel lipid isolation, preconcentration, and clean-up method using pipettes containing immobilized metal ion affinity chromatography (IMAC) medium was used. Results The polar phospholipids present in the normal and dry eye rabbit tears showed both similarities and differences. Species related to platelet-activating factor (PAF) and/or lysophosphatidylcholine (lyso-PC), phosphatidylcholine (PC), and sphingomyelin (SM) were found in both the normal and dry eye rabbit tears. However, the number of types and the concentrations of SM molecules were markedly greater in the dry eye tears than in the normal tears. In addition, phosphatidylserine (PS) species that were readily detectable in dry eye tears were not found in normal tears. Conclusions The combination of immobilized metal ion affinity chromatography and the solid ionic crystal matrix for MALDI enabled the detection and study of phosphorylated lipids in the tears. Specific differences between phospholipid levels in normal and dry eye tears were observable with this methodology. The appearance of various SM species only in the dry eye tears may provide markers for this disease state in the future. PMID:16877399
Fluorophotometric measurement of the buffering action of human tears in vivo.
Yamada, M; Kawai, M; Mochizuki, H; Hata, Y; Mashima, Y
1998-10-01
The buffering action of human tears is thought to be important to keep its pH constant. We measured the change in pH in the precorneal tear film in vivo when the acidic solution is challenged, using a fluorophotometric technique. Twelve eyes from 6 healthy subjects were entered in this study. Each subject was pretreated with either one drop of 0.4% oxybuprocaine for once (light anesthesia), three times (deep anesthesia), or none (controls). The measurement was initiated by instilling 20 microl of 0.067 M phosphate buffer at pH 5.5 containing 2 mM bis-carboxyethyl-carboxyfluorescein free acid, a pH sensitive dye, into the subject's eye. The pH was determined by the ratio of fluorescent intensities at two excitation wavelengths (490 and 430 nm). pH recovery time (PHRT) as defined by the time required for pH to reach 95% of pH at equilibrium was used for the marker of tear buffering action. Tear turnover rate was also determined using the fluorescent decay curve at 430 nm, which was independent of pH, but dependent on dye concentration. Immediately after the instillation, the pH value in the tear film was around 6.0-6.5 in all cases. The tear film rapidly became more alkaline, reaching its normal value in 2.3 +/- 0.5 min in untreated eyes. The pretreatment with 0.4% oxybuprocaine retarded the neutralization process. A single regression analysis revealed that the PHRT had a significant negative correlation with the tear turnover rate (r = -0.78). Our results suggest that the neutralization process of tears largely depends on the tear turnover rate. The buffering action of tears in vivo consists of the tear turnover as well as its chemical buffering capacity.
Pahwa, Shivani; Srivastava, Deep N; Sharma, Raju; Gamanagatti, Shivanand; Kotwal, Prakash P; Sharma, Vijay
2014-01-01
Aims: To compare conventional magnetic resonance imaging (MRI) and direct magnetic resonance (MR) arthrography in the evaluation of triangular fibrocartilage complex (TFCC) and intrinsic wrist ligament tears. Materials and Methods: T1-weighted, fat suppressed (FS) proton density plus T2-weighted (FS PD/T2), 3D multiple-echo data image combination (MEDIC) sequences and direct MR arthrography were performed in 53 patients with wrist pain. Images were evaluated for the presence and location of TFCC, scapholunate ligament (SLL) and lunatotriquetral ligament (LTL) tears, and imaging findings were compared with operative findings in 16 patients who underwent arthroscopy or open surgery (gold standard). Results: Sixteen patients underwent arthroscopy/open surgery: 12 TFCC tears were detected arthroscopically out of which 9 were detected on FS PD/T2 sequence, 10 on MEDIC sequence, and all 12 were detected on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in the detection of TFCC tears were 75%, 83.3%, and 100%, respectively. Out of the eight arthroscopically confirmed SLL tears, three tears were detected on FS PD/T2 sequence, five on MEDIC sequence, and all eight were visualized on MR arthrography. The sensitivities of FS PD/T2, MEDIC sequences, and MR arthrography in detecting SLL tears were 37.5%, 62.5%, and 100%, respectively. One arthroscopically confirmed LTL tear was diagnosed on FS PD/T2 sequence, three on MEDIC sequence, and all five arthroscopically confirmed LTL tears were detected with MR arthrography. The sensitivities of PD, MEDIC sequences, and MR arthrography in detecting LTL tears were 20%, 40%, and 100%, respectively. Conclusions: MR arthrography is the most sensitive and specific imaging modality for the evaluation of wrist ligament tears. PMID:25114389
Forkel, Philipp; Reuter, Sven; Sprenker, Frederike; Achtnich, Andrea; Herbst, Elmar; Imhoff, Andreas; Petersen, Wolf
2015-01-01
Posterior lateral meniscus root tears (PLMRTs) affect the intra-articular pressure distribution in the lateral compartment of the knee. The biomechanical consequences of these injuries are significantly influenced by the integrity of the meniscofemoral ligaments (MFLs). A newly introduced arthroscopic classification system for PLMRTs that takes MFL integrity into account has not yet been clinically applied but may be useful in selecting the optimal method of PLMRT repair. Prospective ACL reconstruction data were collected. Concomitant injuries of the lateral meniscus posterior horn were classified according to their shape and MFL status. The classifications were: type 1, avulsion of the root; type 2, radial tear of the lateral meniscus posterior horn close to the root with an intact MFL; and type 3, complete detachment of the posterior meniscus horn. Between January 2011 and May 2012, 228 consecutive ACL reconstructions were included. Lateral and medial meniscus tears were identified in 38.2% (n = 87) and 44.7% (n = 102), respectively. Of the 87 lateral meniscus tears, 32 cases had PLMRTs; the overall prevalence of PLMRTs was 14% (n = 32). Two medial meniscus root tears were detected. All PLMRTs were classified according to the classification system described above, and the fixation procedure was adapted to the type of meniscus tear. The PLMRT tear is a common injury among patients undergoing ACL repair and can be arthroscopically classified into three different types. Medial meniscus root tears are rare in association with ACL tears. The PLMRT classification presented here may help to estimate the injury's impact on the lateral compartment and to identify the optimal treatment. These tears should not be overlooked, and the treatment strategy should be chosen with respect to the type of root tear. IV.
The effect of a rotator cuff tear and its size on three-dimensional shoulder motion.
Kolk, Arjen; Henseler, Jan Ferdinand; de Witte, Pieter Bas; van Zwet, Erik W; van der Zwaal, Peer; Visser, Cornelis P J; Nagels, Jochem; Nelissen, Rob G H H; de Groot, Jurriaan H
2017-06-01
Rotator cuff-disease is associated with changes in kinematics, but the effect of a rotator cuff-tear and its size on shoulder kinematics is still unknown in-vivo. In this cross-sectional study, glenohumeral and scapulothoracic kinematics of the affected shoulder were evaluated using electromagnetic motion analysis in 109 patients with 1) subacromial pain syndrome (n=34), 2) an isolated supraspinatus tear (n=21), and 3) a massive rotator cuff tear involving the supraspinatus and infraspinatus (n=54). Mixed models were applied for the comparisons of shoulder kinematics between the three groups during abduction and forward flexion. In the massive rotator cuff-tear group, we found reduced glenohumeral elevation compared to the subacromial pain syndrome (16°, 95% CI [10.5, 21.2], p<0.001) and the isolated supraspinatus tear group (10°, 95% CI [4.0, 16.7], p=0.002) at 110° abduction. Reduced glenohumeral elevation in massive rotator cuff tears coincides with an increase in scapulothoracic lateral rotation compared to subacromial pain syndrome (11°, 95% CI [6.5, 15.2], p<0.001) and supraspinatus tears (7°, 95% CI [1.8, 12.1], p=0.012). Comparable differences were observed for forward flexion. No differences in glenohumeral elevation were found between the subacromial pain syndrome and isolated supraspinatus tear group during arm elevation. The massive posterosuperior rotator cuff-tear group had substantially less glenohumeral elevation and more scapulothoracic lateral rotation compared to the other groups. These observations suggest that the infraspinatus is essential to preserve glenohumeral elevation in the presence of a supraspinatus tear. Shoulder kinematics are associated with rotator cuff-tear size and may have diagnostic potential. Copyright © 2017 Elsevier Ltd. All rights reserved.
Radiographic progression of arthritic changes in shoulders with degenerative rotator cuff tears.
Chalmers, Peter N; Salazar, Dane H; Steger-May, Karen; Chamberlain, Aaron M; Stobbs-Cucchi, Georgia; Yamaguchi, Ken; Keener, Jay D
2016-11-01
Very little longitudinal information has been available regarding the relationship of cuff tears and arthritis. The purpose of this study was to determine the midterm risk of and risk factors for rotator cuff tear arthropathy progression in a cohort of subjects with an asymptomatic rotator cuff tear. Baseline (visit 1), 5-year (visit 2), and most recent follow-up (visit 3) radiographs were reviewed in a cohort of 105 subjects enrolled for longitudinal surveillance of asymptomatic degenerative rotator cuff tears and 33 controls. The radiographs were assessed in a blinded, randomized fashion by 3 observers who graded glenohumeral arthritic changes using the Hamada scores, Samilson-Prieto (SPO) scores, and acromiohumeral interval (AHI). Osteoarthritis (SPO classification), cuff tear arthropathy (Hamada classification), and AHI progressed between visits 1 and 3 (median, 8 years; P < .001 in all cases). SPO progression was not significantly different for partial- vs. full-thickness vs. control baseline tear types (P = .19). Both full-thickness and partial-thickness tears had greater progression in Hamada scores than controls did in the first 5 years of follow-up (P = .02 and P = .03, respectively), but scores did not differ between partial- and full-thickness tears. Tears with and without enlargement did not differ in progression in SPO grade, Hamada grade, or AHI. Glenohumeral arthritic changes progress significantly but remain minimal within an 8-year period in early to moderate degenerative cuff disease. Whereas the presence of a rotator cuff tear influences progression in Hamada grade, the magnitude of radiographic progression is not influenced by tear severity or enlargement at midterm time points. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
van der List, Jelle P; DiFelice, Gregory S
2017-10-01
The general opinion is that outcomes of open primary repair of the anterior cruciate ligament (ACL) in the historical literature were disappointing. Since good outcomes of primary repair of proximal tears have recently been reported, we aimed to assess the role of tear location on open primary repair outcomes in the historical literature. All studies reporting outcomes of open primary ACL repair published between the inception of PubMed, Embase and Cochrane and 2000 were identified. Studies were included if tear location was reported. Outcome scores, return to sports, stability examinations, failures and patient satisfaction were collected and reviewed in the total study cohort and in a subgroup of studies treating only proximal tears. Spearman correlation analysis was performed between the percentage of proximal tears in the studies and all outcomes. Twenty-nine studies were included reporting outcomes of open primary in 1457 patients of which 72% had proximal and 23% midsubstance tears. Mean age was 30years, 65% were males, and mean follow-up was 3.6years. Good outcomes were noted in the total cohort, and excellent outcomes were noted following repair of proximal tears. Positive correlation was found between the percentage proximal tears in the studies and percentage satisfied patients (p=0.010). Tear location seems to have played a role on the outcomes of open primary ACL repair. Outcomes of open primary repair in patients with proximal tears were excellent, which confirms there may be a potential role for primary repair as treatment for proximal ACL tears. Copyright © 2017 Elsevier B.V. All rights reserved.
Learning curve of office-based ultrasonography for rotator cuff tendons tears.
Ok, Ji-Hoon; Kim, Yang-Soo; Kim, Jung-Man; Yoo, Tae-Wook
2013-07-01
To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard. The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement. The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners. The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint. Diagnostic study, Level II.
Effects of DA-6034 on aqueous tear fluid secretion and conjunctival goblet cell proliferation.
Choi, Seul Min; Lee, Yeong Geon; Seo, Mi Jung; Kang, Kyung Koo; Ahn, Byoung Ok; Yoo, Moohi
2009-06-01
This study was conducted to evaluate the effect of DA-6034, a potent secretagogue, on aqueous tear fluid secretion and its quality in normal rabbit. We also evaluated, in animal models of experimentally induced dry eye disease, its effectiveness over time to stimulate aqueous tear production by ocular ferning test and goblet cell proliferation. Aqueous tear production, total protein levels, and glycoprotein levels in normal rabbits were evaluated after topical application of DA-6034 (0.3, 1, and 3%). Moreover, time course aqueous tear volume measurement and ocular ferning test in tear fluid were performed in dry eyes of rabbits that had been given 1% atropine sulfate, topically. Altogether, tear fluid production and conjunctival goblet cell numbers were measured in dry eyes of mice that had been given topical scopolamine. Topical application of DA-6034 (0.3, 1, and 3%) significantly increased (P < 0.05) aqueous tear production in a concentration-dependent manner in normal rabbits. There was no change in total protein levels while glycoprotein levels were significantly increased (P < 0.05) at 3% DA-6034. The increase in aqueous tear fluid was significant (P < 0.05) and lasted for 2 h post-instillation in dry eyes of rabbits that had been given 1% atropine sulfate; 10-day repeated instillation of the drug in this model resulted in large and homogeneous fern-like tear patterns. In a mouse model, DA-6034 given as a 3% eyedrop solution significantly increased (P < 0.05) tear fluid production and conjunctival goblet cell number. These results suggest that DA-6034 accelerates not only tear secretion but also mucin production and may be a potential therapeutic agent for the treatment of dry eye disease.
Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul
2015-11-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.
Park, Gi-Young; Lee, Sang Chul
2015-01-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340
Sebbag, Lionel; Park, Shin Ae; Kass, Philip H; Maggs, David J; Attar, Mayssa; Murphy, Christopher J
2017-07-01
To evaluate repeatability and reproducibility of tear osmolarity measured using the TearLab ™ osmometer in normal dogs and to assess its diagnostic potential in dogs with keratoconjunctivitis sicca (KCS). Beagle dogs; six normal and five with KCS. Tear osmolarity and Schirmer tear test-1 (STT-1) values were obtained at various times. Normal dogs were assessed for diurnal variation and repeatability and reproducibility of measurements. Dogs with KCS were evaluated before and after 5 months' topical twice-daily therapy with 2% cyclosporine. Mean ± SD tear osmolarity (mOsm/L) was significantly higher in normal dogs (337.4 ± 16.2) than in dogs with KCS before therapy (306.2 ± 18.0; P < 0.0001), but not following therapy with 2% cyclosporine (330.5 ± 13.7; P = 1.00). Osmolarity readings lower than 325.5 mOsm/L were suggestive of KCS (84.8% sensitivity and 87.1% specificity). In normal dogs, tear osmolarity readings were stable during the daytime (P = 0.99). Repeated measurements revealed high variability and typically poor-to-moderate repeatability and reproducibility, although this was improved by taking three successive measurements at each session. Considering combined data from all dogs, a positive correlation existed between STT-1 and tear osmolarity measurements (Pearson's correlation test, P = 0.04, r = 0.62). Canine tear osmolarity as determined by TearLab ™ osmometer was variable, required multiple readings to be informative, and differed from values reported for humans. Dogs with KCS had a lower tear osmolarity than did normal dogs, and this increased following cyclosporine therapy. © 2016 American College of Veterinary Ophthalmologists.
Fiske-Jackson, A R; Barker, W H J; Eliashar, E; Foy, K; Smith, R K W
2013-01-01
The sensitivity of ultrasonography for the diagnosis of manica flexoria (MF) tears within the digital flexor tendon sheath (DFTS) is lower than for diagnosis of marginal tears of the deep digital flexor tendon (DDFT). Additional diagnostic tools would assist in appropriate decision making for either conservative or surgical management. To evaluate the improvement in lameness of horses with MF or DDFT tears following intrathecal analgesia and to assess the sensitivity and specificity of contrast radiography for the diagnosis of these tears. The case records of horses presented to a referral clinic over a 7-year period that underwent intrathecal diagnostic analgesia, or intrathecal analgesia and contrast radiography, of the DFTS with subsequent tenoscopy were examined. Fifty-three limbs had intrathecal diagnostic analgesia performed and 23 contrast tenograms were assessed in horses undergoing DFTS tenoscopy. Horses with DDFT tears were significantly more likely to respond positively to intrathecal diagnostic analgesia than those with MF tears (P = 0.02). Using contrast radiography, tears of the MF were predicted with an overall sensitivity of 96% and specificity of 80%; marginal tears of the DDFT were predicted with an overall sensitivity of 57% and specificity of 84%. The results of intrathecal analgesia of the DFTS in combination with contrast radiography have a high sensitivity for predicting MF tears. The sensitivity of contrast radiography for predicting tears of the DDFT is lower but the specificity remains high. Contrast radiography performed at the same time as intrathecal analgesia provides useful information regarding the presence of MF tears and DDFT tears, which can assist in the decision of whether to manage the lameness conservatively or with tenoscopic evaluation. © 2012 EVJ Ltd.
Army Excellence in Leadership (AXL): Educating Army Leaders with the Tripwire Film
2007-03-01
after being placed into your DVD- ROM drive. Once open, you have the choice of playing the film or viewing the trailer . If, after inserting the DVD...8217 suggestions, he himself was not receptive to feedback, and he failed to delegate responsibilities. Questions to facilitate the discussion of establishing trust...about leadership: Mentoring with movies and interactive characters. Proceedings of the 15th Innovative Applications of Artificial Intelligence
Gene expression profiles of changes underlying different-sized human rotator cuff tendon tears.
Chaudhury, Salma; Xia, Zhidao; Thakkar, Dipti; Hakimi, Osnat; Carr, Andrew J
2016-10-01
Progressive cellular and extracellular matrix (ECM) changes related to age and disease severity have been demonstrated in rotator cuff tendon tears. Larger rotator cuff tears demonstrate structural abnormalities that potentially adversely influence healing potential. This study aimed to gain greater insight into the relationship of pathologic changes to tear size by analyzing gene expression profiles from normal rotator cuff tendons, small rotator cuff tears, and large rotator cuff tears. We analyzed gene expression profiles of 28 human rotator cuff tendons using microarrays representing the entire genome; 11 large and 5 small torn rotator cuff tendon specimens were obtained intraoperatively from tear edges, which we compared with 12 age-matched normal controls. We performed real-time polymerase chain reaction and immunohistochemistry for validation. Torn rotator cuff tendons demonstrated upregulation of a number of key genes, such as matrix metalloproteinase 3, 10, 12, 13, 15, 21, and 25; a disintegrin and metalloproteinase (ADAM) 12, 15, and 22; and aggrecan. Amyloid was downregulated in all tears. Small tears displayed upregulation of bone morphogenetic protein 5. Chemokines and cytokines that may play a role in chemotaxis were altered; interleukins 3, 10, 13, and 15 were upregulated in tears, whereas interleukins 1, 8, 11, 18, and 27 were downregulated. The gene expression profiles of normal controls and small and large rotator cuff tear groups differ significantly. Extracellular matrix remodeling genes were found to contribute to rotator cuff tear pathogenesis. Rotator cuff tears displayed upregulation of a number of matrix metalloproteinase (3, 10, 12, 13, 15, 21, and 25), a disintegrin and metalloproteinase (ADAM 12, 15, and 22) genes, and downregulation of some interleukins (1, 8, and 27), which play important roles in chemotaxis. These gene products may potentially have a role as biomarkers of failure of healing or therapeutic targets to improve tendon healing. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Updegrove, Gary F; Armstrong, April D; Mosher, Timothy J; Kim, H Mike
2015-11-01
To characterize the orientation of the normal supraspinatus central tendon and describe the displacement patterns of the central tendon in rotator cuff tears using a magnetic resonance imaging (MRI)-based method. We performed a retrospective MRI and chart review of 183 patients with a rotator cuff tear (cuff tear group), 52 with a labral tear but no rotator cuff tear (labral tear group), and 74 with a normal shoulder (normal group). The orientation of the supraspinatus central tendon relative to the bicipital groove was evaluated based on axial MRI and was numerically represented by the shortest distance from the lateral extension line of the central tendon to the bicipital groove. Tear size, fatty degeneration, and involvement of the anterior supraspinatus were evaluated to identify the factors associated with orientation changes. The mean distance from the bicipital groove to the central tendon line was 0.7 mm and 1.3 mm in the normal group and labral tear group, respectively. Full-thickness cuff tears involving the anterior supraspinatus showed a significantly greater distance (17.7 mm) than those sparing the anterior supraspinatus (4.9 mm, P = .001). Fatty degeneration of the supraspinatus was significantly correlated with the distance (P = .006). Disruption of the anterior supraspinatus and fatty degeneration of the supraspinatus were independent predictors of posterior displacement. The supraspinatus central tendon has a constant orientation toward the bicipital groove in normal shoulders, and the central tendon is frequently displaced posteriorly in full-thickness rotator cuff tears involving the anterior leading edge of the supraspinatus. The degree of posterior displacement is proportional to tear size and severity of fatty degeneration of the supraspinatus muscle. A simple and quick assessment of the central tendon orientation on preoperative MRI can be a useful indicator of tear characteristics, potentially providing insight into the intraoperative repair strategy. Level IV, diagnostic case-control study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Comparison of the accuracy rates of 3-T and 1.5-T MRI of the knee in the diagnosis of meniscal tear.
Grossman, Jeffrey W; De Smet, Arthur A; Shinki, Kazuhiko
2009-08-01
The purpose of this study was to compare the accuracy of 3-T MRI with that of 1.5-T MRI of the knee in the diagnosis of meniscal tear and to analyze the causes of diagnostic error. We reviewed the medical records and original MRI interpretations of 100 consecutive patients who underwent 3-T MRI of the knee and of 100 consecutive patients who underwent 1.5-T MRI of the knee to determine the accuracy of diagnoses of meniscal tear. Knee arthroscopy was the reference standard. We retrospectively reviewed all MRI diagnostic errors to determine the cause of the errors. At arthroscopy, 109 medial and 77 lateral meniscal tears were identified in the 200 patients. With two abnormal MR images indicating a meniscal tear, the sensitivity and specificity for medial tear were 92.7% and 82.2% at 1.5-T MRI and 92.6% and 76.1% at 3-T MRI (p = 1.0, p = 0.61). The sensitivity and specificity for lateral tears were 68.4% and 95.2% at 1.5-T MRI and 69.2% and 91.8% at 3-T MRI (p = 1.0, p = 0.49). Of the false-positive diagnoses of medial meniscal tear, five of eight at 1.5 T and seven of 11 at 3 T were apparent peripheral longitudinal tears of the posterior horn. Fifteen of the 26 missed medial and lateral meniscal tears were not seen in retrospect even with knowledge of the tear type and location. Allowing for sample size limitations, we found comparable accuracy of 3-T and 1.5-T MRI of the knee in the diagnosis of meniscal tear. The causes of false-positive and false-negative MRI diagnoses of meniscal tear are similar for 3-T and 1.5-T MRI.
Assay of mucins in human tear fluid.
Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene
2007-05-01
Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 > 0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention.
Assay of Mucins in Human Tear Fluid
Spurr-Michaud, Sandra; Argüeso, Pablo; Gipson, Ilene
2007-01-01
Mucin genes, both secreted (MUC2, MUC5AC, MUC5B, MUC7) and membrane associated (MUC1, MUC4, MUC16), have been reported to be expressed by ocular surface epithelia. The purpose of this study was to comprehensively assay the mucin content of human tear fluid using multiple antibodies for each mucin and to develop a sensitive, semi-quantitative method for the assay of mucins in tears. Tear washes were obtained by instillation of saline onto the ocular surface, followed by collection from the inferior fornix. Tear proteins were separated in 1% agarose gels, transferred to nitrocellulose membrane by vacuum blotting and probed with multiple antibodies recognizing MUC1, MUC2, MUC4, MUC5AC, MUC5B, MUC7 and MUC16. Binding was detected using chemiluminescence, and quantity was determined by densitometry. Serial dilutions of pooled tears from normal individuals were assayed to determine the linear range of detectability. MUC1, MUC4, MUC16, MUC5AC and low levels of MUC2 were consistently detected in human tear fluid, while MUC5B and MUC7 were not. Use of several antibodies recognizing different epitopes on the same mucin confirmed these findings. The antibodies to mucins bound to serial dilutions of tears in a linear fashion (r2 >0.9), indicating the feasibility of semi-quantitation. MUC5AC in tear fluid had an increased electrophoretic mobility compared to MUC5AC isolated from conjunctival tissue. This study provides clear evidence that the mucin component of tears is a mixture of secreted and shed membrane-associated mucins, and for the first time demonstrates MUC16 in tear fluid. Immunoblots of tears using agarose gel electrophoresis and chemiluminescence detection provide a semi-quantitative assay for mucin protein that will be useful for comparisons with tears from diseased eyes or after pharmacological intervention. PMID:17399701
Evaluation of the Effects of Conjunctivochalasis Excision on Tear Stability and Contrast Sensitivity
Qiu, Weiqiang; Zhang, Mingzhou; Xu, Ting; Liu, Ziyuan; Lv, Huibin; Wang, Wei; Li, Xuemin
2016-01-01
Conjunctivochalasis (CCh) disrupts tear flow and damages tear film stability. This study sought to evaluate the tear stability and contrast sensitivity of patients with CCh on whom CCh excision was performed. The study included 39 eyes from 39 patients; all patients had eyes with grade 2 or 3 CCh, underwent CCh excision, and were evaluated before and three months after the surgery. The evaluated variables included the ocular surface disease index (OSDI), the tear break-up time (TBUT), corneal fluorescein staining, corneal surface irregularity, Schirmer’s I test, the tear meniscus area (TMA), and contrast sensitivity. A follow-up of three months was achieved in 36 eyes for 36 patients. All parameters improved significantly after surgery (p < 0.05), except Schirmer’s I test, thus suggesting that CCh excision is an effective method for reconstructing the lower tear meniscus and improving both tear film stability and corneal surface irregularity. The results further demonstrated a simultaneous increase in contrast sensitivity after surgery. PMID:27892479
Diagnosis of dry eye disease and emerging technologies
Zeev, Maya Salomon-Ben; Miller, Darby Douglas; Latkany, Robert
2014-01-01
Dry eye is one of the most commonly encountered problems in ophthalmology. Signs can include punctate epithelial erosions, hyperemia, low tear lakes, rapid tear break-up time, and meibomian gland disease. Current methods of diagnosis include a slit-lamp examination with and without different stains, including fluorescein, rose bengal, and lissamine green. Other methods are the Schirmer test, tear function index, tear break-up time, and functional visual acuity. Emerging technologies include meniscometry, optical coherence tomography, tear film stability analysis, interferometry, tear osmolarity, the tear film normalization test, ocular surface thermography, and tear biomarkers. Patient-specific considerations involve relevant history of autoimmune disease, refractive surgery or use of oral medications, and allergies or rosacea. Other patient considerations include clinical examination for lid margin disease and presence of lagophthalmos or blink abnormalities. Given a complex presentation and a variety of signs and symptoms, it would be beneficial if there was an inexpensive, readily available, and reproducible diagnostic test for dry eye. PMID:24672224
Harryman, Douglas T; Hettrich, Carolyn M; Smith, Kevin L; Campbell, Barry; Sidles, John A; Matsen, Frederick A
2003-04-01
Rotator cuff tears are among the most common conditions of the shoulder. One of the major difficulties in studying patients with rotator cuff tears is that the clinical expression of these tears varies widely and different practices may have substantially different patient populations. The goals of the present prospective multipractice study were to use patient self-assessment questionnaires (1) to identify some of the characteristics of patients with rotator cuff tears, other than the size of the cuff tear, that are correlated with shoulder function, and (2) to determine whether there are significant differences in these characteristics among patients from the practices of different surgeons. Ten surgeons enrolled a total of 333 patients with a full-thickness tear of the supraspinatus tendon into this prospective study. Each patient completed self-assessment questionnaires that included items regarding demographic characteristics, prior treatment, medical and social comorbidities, general health status, and shoulder function. As expected, patients who had an infraspinatus tendon tear as well as a supraspinatus tendon tear had significantly worse ability to use the arm overhead compared with those who had a supraspinatus tear alone (p < 0.005). However, shoulder function and health status were correlated with patient characteristics other than the size of the rotator cuff tear. The number of shoulder functions that were performable was correlated with the subscales of the Short Form-36 and was inversely associated with medical and social comorbidities. The patients from the ten different surgeon practices showed significant differences in almost every parameter, including age, gender, method of tear documentation, tear size, prior treatment, medical and social comorbidities, general health status, and shoulder function. Clinical studies on the natural history of rotator cuff tears and the effectiveness of treatment must control for a wide range of variables, many of which do not pertain directly to the shoulder. Patients from the practices of different surgeons cannot be assumed to be similar with respect to these variables. Patient self-assessment questionnaires appear to offer a practical method of uniform assessment across different practices.
Stability and in vitro toxicity of an infliximab eye drop formulation.
Robert, Marie-Claude; Spurr-Michaud, Sandra; Frenette, Mathieu; Young, David; Gipson, Ilene K; Dohlman, Claes H
2014-01-01
The purpose of this study was to develop a novel 10-mg/mL infliximab eye drop, to characterize its physical and biological stability under recommended storage conditions, and to assess the formulation's toxicity to ocular surface epithelium in vitro. Infliximab (10 mg/mL) was reconstituted using equal volumes of sterile water and 1% carboxymethylcellulose artificial tears. Aliquots were stored in either a 4 degrees C refrigerator or -20 degrees C freezer for up to 45 days. Physical stability was assessed through monitoring the solution's appearance, pH, ultraviolet-visible-near infrared absorbance and scattering, as well as protein gel electrophoresis. Biological stability was assayed through binding to tumor necrosis factor-alpha using an enzyme-linked immunosorbent assay. In vitro cytotoxicity to human corneal-limbal epithelial cells was examined following a 4-hour exposure to the study drug. Refrigerated and frozen infliximab eye drops remained clear and colorless for the duration of study. The formulation's pH (7.0) was comparable to that of the artificial tear vehicle alone. Low levels of ultraviolet-visible-near infrared light absorbance and scattering established the lack of protein precipitate after refrigeration or freezing. Protein gel electrophoresis performed under reducing conditions revealed the presence of two main protein bands of approximately 50 kDa and 25 kDa, representing immunoglobulin G heavy and light chains. The migration pattern of the proteins did not change under the different storage conditions and between day 10 and 45 after formulation. Infliximab binding to tumor necrosis factor-alpha remained stable for up to 45 days, with conservation of 101% and 102% of its initial binding activity when refrigerated or frozen, respectively. In vitro human corneal-limbal epithelial cultures showed no increase in cytotoxicity with infliximab treatment when compared to vehicle and culture media controls (P > 0.05). Infliximab can be formulated as an eye drop and remains stable when stored in accordance with current regulations regarding compounded eye drops. The demonstrated physical and biological stability as well as in vitro innocuity of this infliximab eye drop formulation may facilitate future clinical investigation targeting tumor necrosis factor-alpha as a modulator of various ocular surface diseases.
Hartmann, Xavier H M; van der Linde, Peter; Homburg, Erik F G A; van Breemen, Lambert C A; de Jong, Arthur M; Luttge, Regina
2015-11-18
Arrays of microneedles (MNAs) are integrated in an out-of-plane fashion with a base plate and can serve as patches for the release of drugs and vaccines. We used soft-lithography and micromolding to manufacture ceramic nanoporous (np)MNAs. Failure modes of ceramic npMNAs are as yet poorly understood and the question remained: is our npMNA platform technology ready for microneedle (MN) assembly into patches? We investigated npMNAs by microindentation, yielding average crack fracture forces above the required insertion force for a single MN to penetrate human skin. We further developed a thumb pressure-actuated applicator-assisted npMNA insertion method, which enables anchoring of MNs in the skin by an adhesive in one handling step. Using a set of simple artificial skin models, we found a puncture efficiency of this insertion method a factor three times higher than by applying thumb pressure on the npMNA base plate directly. In addition, this new method facilitated zero MN-breakage due to a well-defined force distribution exerted onto the MNs and the closely surrounding area prior to bringing the adhesive into contact with the skin. Owing to the fact that such parameter space exists, we can conclude that npMNAs by soft lithography are a platform technology for MN assembly into a patch.
Kovtunov, E A; Shelud'ko, A V; Chernyshova, M P; Petrova, L P; Katsy, E I
2013-11-01
Bacteria Azospirillum brasilense have mixed flagellation: in addition to the polar flagellum, numerous lateral flagella are formed in their cells on medium with increased density. Flagella determine the active swimming and swarming capacities of azospirilla. Using A. brasilense Sp245 as an example, we showed that the Omegon-Km artificial transposon insertion into the chromosomal gene for 3-hydroxyisobutyrate dehydrogenase (mmsB) was concurrent with the appearance of significant defects in the formation of polar flagella and with the paralysis of lateral flagella. The Sp245 mutant with the Omegon insertion into the plasmid AZOBR_p1-borne gene for 3-oxoacyl-[acyl-carrier protein]-reductase (fabG) showed the complete loss of flagella and the swarming capacity, as well as significant defects in polar flagellar assembly (though some cells are still motile in liquid medium). The viability of the A. brasilense Sp245 mutants with the Omegon insertion into the mmsB or fabG gene was not reduced. No considerable differences in the fatty acid composition of whole cell lipid extracts were found for the A. brasilense Sp245 strain and its mmsB and fabG mutants.
Measurement of Tear Production in English Angora and Dutch Rabbits
Rajaei, Seyed Mehdi; Rafiee, Siamak Mashhady; Ghaffari, Masoud Selk; Masouleh, Mohammad N; Jamshidian, Mahmoud
2016-01-01
The purpose of this study was to establish normal values for tear production tests in different breeds of domestic rabbits. Healthy adult rabbits (n = 60; 120 eyes) of 2 different breeds (English angora and Dutch; n = 15 of each sex and breed) were used in this study. Tear production was measured by using the 1-min Schirmer tear test (STT), phenol red thread test (PRTT), and endodontic absorbent paper point tear test (EAPTT). In addition, horizontal palpebral fissure length was evaluated as a measure of ocular adnexal dimensions. Tear production (mean ± 1 SD) in English angora rabbits was 5.4 ± 1.6 mm/min according to the STT, 25.0 ± 2.7 mm in 15 s for the PRTT, and 18.8 ± 2.1 mm/min by the EAPTT; in Dutch rabbits, these values were 4.6 ± 1.2 mm/min, 23.6 ± 2.3 mm in 15 s, and 16.9 ± 1.7 mm/min, respectively. Only the EAPTT revealed a significant difference in tear production between English Angora and Dutch rabbits. These results provide reference values for tear production in English Angora and Dutch rabbits according to 3 different quantitative tear film assessment methods. PMID:27025815
In vivo performance of a microelectrode neural probe with integrated drug delivery
Rohatgi, Pratik; Langhals, Nicholas B.; Kipke, Daryl R.; Patil, Parag G.
2014-01-01
Object The availability of sophisticated neural probes is a key prerequisite in the development of future brain machine interfaces (BMI). In this study, we developed and validated a neural probe design capable of simultaneous drug delivery and electrophysiology recordings in vivo. Focal drug delivery has promise to dramatically extend the recording lives of neural probes, a limiting factor to clinical adoption of BMI technology. Methods To form the multifunctional neural probe, we affixed a 16-channel microfabricated silicon electrode array to a fused silica catheter. Three experiments were conducted to characterize the performance of the device. Experiment 1 examines cellular damage from probe insertion and the drug distribution in tissue. Experiment 2 measures the effects of saline infusions delivered through the probe on concurrent electrophysiology. Experiment 3 demonstrates that a physiologically relevant amount of drug can be delivered in a controlled fashion. For these experiments, Hoechst and propidium iodide were used to assess insertion trauma and the tissue distribution of the infusate. Artificial cerebral spinal fluid and tetrodotoxin were injected to determine the efficacy of drug delivery. Results The newly developed multifunctional neural probes were successfully inserted into rat cortex and were able to deliver fluids and drugs that resulted in the expected electrophysiological and histological responses. The damage from insertion of the device into brain tissue was substantially less than the volume of drug dispersion in tissue. Electrophysiological activity, including both individual spikes as well as local field potentials, was successfully recorded with this device during real-time drug delivery. No significant changes were seen in response to delivery of artificial cerebral spinal fluid as a control experiment, whereas delivery of tetrodotoxin produced the expected result of suppressing all spiking activity in the vicinity of the catheter outlet. Conclusions Multifunctional neural probes such as the ones developed and validated within this study have great potential to help further understand the design space and criteria for the next generation of neural probe technology. By incorporating integrated drug delivery functionality into the probes, new treatment options for neurological disorders and regenerative neural interfaces utilizing localized and feedback controlled delivery of drugs can be realized in the near future. PMID:19569896
Effect of topical ophthalmic epinastine and olopatadine on tear volume in mice.
Villareal, Arturo L; Farley, William; Pflugfelder, Stephen C
2006-12-01
To investigate the effects of topical epinastine and olopatadine on tear volume by using a mouse model. Eighty-five C57BL6 mice (170 eyes) were treated twice daily with topical ophthalmic epinastine 0.05%, olopatadine 0.1%, or atropine 1% or served as untreated controls. A thread-wetting assay was used to measure tear volume at baseline and 15, 45, 90, 120, and 240 minutes after the last instillation of the drug on days 2 and 4 of treatment. After 2 days of treatment, epinastine-treated mice showed greater mean tear volumes than olopatadine-treated mice did at 15, 45, 90, and 240 minutes, with statistical significance at 15 and 45 minutes (P<0.001). Olopatadine significantly reduced tear volume versus untreated controls at 15 and 45 minutes (P<0.001). After 4 days, tear volumes with epinastine treatment exceeded those with olopatadine treatment at all time points, with statistical significance at 45 minutes (P<0.05). Atropine rendered tears undetectable at 15, 45, and 90 minutes; tear volume returned to baseline levels at 240 minutes. Topical epinastine did not inhibit tear secretion, whereas olopatadine caused a significant decrease in tear volume. Because of its neutral impact on the lacrimal functional unit, epinastine may be an especially good choice for the treatment of allergic conjunctivitis in patients with dry eye disease or in those who are at risk for developing dry eye.
Effects of tear film dynamics on quality of vision.
Koh, Shizuka; Tung, Cynthia I; Inoue, Yasushi; Jhanji, Vishal
2018-06-15
The precorneal tear film is maintained by blinking and exhibits different phases in the tear cycle. The tear film serves as the most anterior surface of the eye and plays an important role as a first refractive component of the eye. Alterations in tear film dynamics may cause both vision-related and ocular surface-related symptoms. Although the optical quality associated with the tear film dynamics previously received little attention, objective measurements of optical quality using wavefront sensors have enabled us to quantify optical aberrations induced by the tear film. This has provided an objective method for assessing reduced optical quality in dry eye; thus, visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. In addition, sequential measurements of wavefront aberrations have provided us with valuable insights into the dynamic optical changes associated with tear film dynamics. This review will focus on the current knowledge of the mechanisms of wavefront variations that are caused by different aspects of tear film dynamics: specifically, quality, quantity and properties of the tear film, demonstrating the respective effects of dry eye, epiphora and instillation of eye drops on the quality of vision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Lipid peroxidation is increased in tears from the elderly.
Benlloch-Navarro, Soledad; Franco, Ilenia; Sánchez-Vallejo, Violeta; Silvestre, Dolores; Romero, Francisco Javier; Miranda, María
2013-10-01
We describe a procedure in which tears, obtained from Schirmer strips, are used to measure a marker of lipid peroxidation, malondialdehyde (MDA). We also compared the levels of proteins and MDA in tears from two groups of people: young adults (18-30 years old) and elderly adults (65-85 years old), because the data related to total protein concentration of human tears vary widely and because the majority of people over the age of 65 experience some symptoms of dry eyes and this condition has been recognized as an oxidative stress-induced disease. Our results show a significant difference in the protein concentration of the tears taken from the two age categories, younger adults (18-30 years old) and older adults (65-85 years old). Herein, we report for the first time an increase in MDA concentrations determined by HPLC in human tears based on age. It is possible that alterations in the tear lipid layer may lead to an increase in lipid peroxidation. Further studies are needed to understand the nature and function of tear film and stability in order to obtain new methods to analyze tears in patients with different diseases. In this sense, it would be interesting to compare MDA concentration in tears from control subjects and from people with meibomian gland dysfunction. Copyright © 2013 Elsevier Ltd. All rights reserved.
Chiva, Andreea
2011-08-15
Dry eye is the most prevalent condition seen by the ophthalmologist, in particular in elderly. The identification of new common risk factors (computer use and contact lens wear) extends the disease among the young people. The early diagnosis of dry eye is essential, but difficult, because the biochemical changes in tear film usually occur before any detectable signs. Due its advantages, electrophoresis of tear proteins could be an important tool for diagnosis of tear film impairment in high risk groups for dry eye. The role of tear proteins electrophoresis in early diagnosis of dry eye related to computer use and contact lens wear, as well as the biochemical changes in these high risk groups are presented. This review will summarize the actual data concerning the electrophoretic changes of tear proteins in computer users and contact lens wearers, two common high risk groups for dry eye. Electrophoresis of tear proteins using automated system Hyrys-Hydrasys SEBIA France is an important tool for early diagnosis of tear film alterations and monitoring of therapy. The quantification of many proteins in a single analysis using a small quantity of unconcentrated reflex tears is the main advantage of this technique. Electrophoresis of tear proteins should became a prerequisite, in particular for computer users less than 3 h/day, as well as at prescribing contact lenses.
Park, Sang-Jun
2015-01-01
Purpose To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. Materials and Methods There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Results Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Conclusions Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn. PMID:26060607
Preexisting Rotator Cuff Tears as a Predictor of Outcomes in National Football League Athletes.
Gibbs, Daniel B; Lynch, T Sean; Gombera, M Mustafa; Saltzman, Matthew D; Nuber, Gordon W; Schroeder, Gregory D; Labelle, Mark; Hollett, Brian P
A preexisting rotator cuff tear may affect the draft status and career performance of National Football League (NFL) players. Preexisting rotator cuff tears decrease a player's draft status, performance, and longevity in the NFL. Retrospective cohort study. Level 3. Medical reports of prospective NFL players during the NFL Scouting Combine from 2003 to 2011 were evaluated to identify players with a previous rotator cuff tear. Athletes were matched to control draftees without documented shoulder pathology by age, position, year drafted, and round drafted. Career statistics and performance scores were calculated. Between 2003 and 2011, 2965 consecutive athletes were evaluated. Forty-nine athletes had preexisting rotator cuff tears: 22 athletes underwent surgical intervention for their tear and 27 were treated nonoperatively. Those with a rotator cuff tear were significantly less likely to be drafted than those without a previous injury (55.1% vs 77.5%, P = 0.002). The 27 drafted athletes with preexisting rotator cuff tears started significantly fewer games (23.7 vs 43.0, P = 0.02) and played significantly fewer years (4.3 vs 5.7, P = 0.04) and significantly fewer games (47.1 vs 68.4, P = 0.04) than matched control athletes without rotator cuff tears. Athletes with a preexisting rotator cuff tear were less likely to be drafted and had decreased career longevity.
Kim, Jin Goo; Lee, Yong Seuk; Bae, Tae Soo; Ha, Jeong Ku; Lee, Dong Hoon; Kim, Young Jae; Ra, Ho Jong
2013-09-01
The purposes of this study were to evaluate the effect on tibiofemoral contact mechanics of repair of the posterior root of the medial meniscus and the effect of meniscal allograft transplantation (MAT) with medial collateral ligament (MCL) release at different flexion angles. Ten fresh-frozen human cadaveric knees (five pairs) were used. A digital pressure sensor was inserted by capsulotomy, and experiments were performed serially under the following six conditions, that is, with an intact medial meniscus (normal controls), with a root tear, after root repair, after total meniscectomy, after MAT, and after MAT plus MCL release. During each experiment, knees were positioned at 0°, 30°, 60°, and 90° of flexion, and peak pressure (kPa) and contact area (cm2) were measured. At 0° of flexion, contact pressure did not differ among the six experimental settings. However, at 30° and 60° of flexion, contact pressure differed significantly between root tear and root repair specimens (p = 0.04 and 0.03, respectively), and between total meniscectomy and MAT specimens (p = 0.02 and 0.03, respectively). On the other hand, mean contact pressures were different between normal (476.7 ± 473.1 and 573.3 ± 479.1 kPa) and root repair (575.7 ± 357.8 and 598.6 ± 415.8), and between normal and MAT (635.7 ± 437.4 and 674.3 ± 533.2). At 0°, 30°, 60°, and 90° of flexion, contact areas differed significantly between normal and total meniscectomy specimens (p = 0.02, 0.01, 0.02, and 0.02, respectively), and between MAT and total meniscectomy specimens (p = 0.03, 0.02, 0.02, and 0.03, respectively). Contact areas differed significantly between root tear and root repair specimens at 60° of flexion (p = 0.04), and between normal control and root repair specimens at 60° and 90° of flexion (p = 0.03 and 0.04, respectively). The effects of MAT plus MCL release on contact mechanics were not different from the effects of MAT alone (n.s.). Both meniscal root repair and transplantation of meniscus improved contact mechanics, but it did not appear that repair of the meniscal root or transplantation of meniscus restores the biomechanical function back to normal level. The MAT plus MCL release was similar to those after MAT alone. Therefore, it is better to preserve meniscus and MCL release could be done during the MAT.
Corneal Sensitivity in Tear Dysfunction and its Correlation with Clinical Parameters and Blink Rate
Rahman, Effie Z.; Lam, Peter K.; Chu, Chia-Kai; Moore, Quianta; Pflugfelder, Stephen C.
2015-01-01
Purpose To compare corneal sensitivity in tear dysfunction due to a variety of causes using contact and non-contact esthesiometers and to evaluate correlations between corneal sensitivity, blink rate and clinical parameters. Design Comparative observational case series. Methods Ten normal and 33 subjects with tear dysfunction [meibomian gland disease (n = 11), aqueous tear deficiency (n = 10) - without (n = 7) and with (n = 3) Sjögren syndrome (SS) and conjunctivochalasis (n = 12)] were evaluated. Corneal sensitivity was measured with Cochet-Bonnet and air jet esthesiometers and blink rate by electromyelography. Eye irritation symptoms, tear meniscus height, tear break-up time (TBUT), and corneal and conjunctival dye staining were measured. Between group means were compared and correlations calculated. Results Compared with control (Cochet-Bonnet 5.45 mm, air esthesiometer 3.62 mg), mean sensory thresholds were significantly higher in aqueous tear deficiency using either Cochet-Bonnet (3.6 mm; P = 0.003) or air (11.7 mg; P = 0.046) esthesiometers, but were not significantly different in the other groups. Reduced corneal sensitivity significantly correlated with more rapid TBUT and blink rate, and greater irritation and ocular surface dye staining with one or both esthesiometers. Mean blink rates were significantly higher in both aqueous tear deficiency and conjunctivochalasis compared with control. Among all subjects, blink rate positively correlated with ocular surface staining and irritation and inversely correlated with TBUT. Conclusion Amongst conditions causing tear dysfunction, reduced corneal sensitivity is associated with greater irritation, tear instability, ocular surface disease and blink rate. Rapid blinking is associated with worse ocular surface disease and tear stability. PMID:26255576