Sample records for assay improves accuracy

  1. Comparison of several von Willebrand factor (VWF) activity assays for monitoring patients undergoing treatment with VWF/FVIII concentrates: improved performance with a new modified automated method.

    PubMed

    Hillarp, A; Friedman, K D; Adcock-Funk, D; Tiefenbacher, S; Nichols, W L; Chen, D; Stadler, M; Schwartz, B A

    2015-11-01

    The ability of von Willebrand factor (VWF) to bind platelet GP Ib and promote platelet plug formation is measured in vitro using the ristocetin cofactor (VWF:RCo) assay. Automated assay systems make testing more accessible for diagnosis, but do not necessarily improve sensitivity and accuracy. We assessed the performance of a modified automated VWF:RCo assay protocol for the Behring Coagulation System (BCS(®) ) compared to other available assay methods. Results from different VWF:RCo assays in a number of specialized commercial and research testing laboratories were compared using plasma samples with varying VWF:RCo activities (0-1.2 IU mL(-1) ). Samples were prepared by mixing VWF concentrate or plasma standard into VWF-depleted plasma. Commercially available lyophilized standard human plasma was also studied. Emphasis was put on the low measuring range. VWF:RCo accuracy was calculated based on the expected values, whereas precision was obtained from repeated measurements. In the physiological concentration range, most of the automated tests resulted in acceptable accuracy, with varying reproducibility dependent on the method. However, several assays were inaccurate in the low measuring range. Only the modified BCS protocol showed acceptable accuracy over the entire measuring range with improved reproducibility. A modified BCS(®) VWF:RCo method can improve sensitivity and thus enhances the measuring range. Furthermore, the modified BCS(®) assay displayed good precision. This study indicates that the specific modifications - namely the combination of increased ristocetin concentration, reduced platelet content, VWF-depleted plasma as on-board diluent and a two-curve calculation mode - reduces the issues seen with current VWF:RCo activity assays. © 2015 John Wiley & Sons Ltd.

  2. Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer

    USDA-ARS?s Scientific Manuscript database

    Background The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed...

  3. [Comparison between anti-ouabain egg yolk(IgY) and rabbit antibody(IgG) in enzyme-linked immunosorbent assay].

    PubMed

    Zhang, Ming-juan; Yang, Jun; Ge, Heng; Qiang, Lei; Duan, Zong-ming; Wang, Cong-xia; Wang, Rong; Lu, Zhuo-rern

    2007-11-01

    To improve specificity and accuracy of endogenous ouabain measurement assay. Anti-ouabain polyclonal antibody egg yolk (IgY) and anti-ouabain rabbit antibody (IgG) were prepared respectively. In the presence of two kinds of antibody, then the specificity and accuracy of enzyme-linked immunosorbent assay (ELISA) were compared. The ELISA, in the presence of IgY, provided a sensitivity of the average intraassay coefficient of variation(CV) was 2.03%, and the inter-assay CV was 2.34% respectively. In contrast, IgG were 2.83% and 3.29%. No significant interferences were observed with hydrocortisone and dexamethasone. There was 3.45% vs. 5.95%, 3.20% vs. 5.20% of crossreaction with cedilanid and digoxin. The specificity and accuracy of ELISA, in which IgY was used, were more better than IgG.

  4. Linkage disequilibrium among commonly genotyped SNP and variants detected from bull sequence

    USDA-ARS?s Scientific Manuscript database

    Genomic prediction utilizing causal variants could increase selection accuracy above that achieved with SNP genotyped by commercial assays. A number of variants detected from sequencing influential sires are likely to be causal, but noticable improvements in prediction accuracy using imputed sequen...

  5. Use of in Vitro HTS-Derived Concentration–Response Data as Biological Descriptors Improves the Accuracy of QSAR Models of in Vivo Toxicity

    PubMed Central

    Sedykh, Alexander; Zhu, Hao; Tang, Hao; Zhang, Liying; Richard, Ann; Rusyn, Ivan; Tropsha, Alexander

    2011-01-01

    Background Quantitative high-throughput screening (qHTS) assays are increasingly being used to inform chemical hazard identification. Hundreds of chemicals have been tested in dozens of cell lines across extensive concentration ranges by the National Toxicology Program in collaboration with the National Institutes of Health Chemical Genomics Center. Objectives Our goal was to test a hypothesis that dose–response data points of the qHTS assays can serve as biological descriptors of assayed chemicals and, when combined with conventional chemical descriptors, improve the accuracy of quantitative structure–activity relationship (QSAR) models applied to prediction of in vivo toxicity end points. Methods We obtained cell viability qHTS concentration–response data for 1,408 substances assayed in 13 cell lines from PubChem; for a subset of these compounds, rodent acute toxicity half-maximal lethal dose (LD50) data were also available. We used the k nearest neighbor classification and random forest QSAR methods to model LD50 data using chemical descriptors either alone (conventional models) or combined with biological descriptors derived from the concentration–response qHTS data (hybrid models). Critical to our approach was the use of a novel noise-filtering algorithm to treat qHTS data. Results Both the external classification accuracy and coverage (i.e., fraction of compounds in the external set that fall within the applicability domain) of the hybrid QSAR models were superior to conventional models. Conclusions Concentration–response qHTS data may serve as informative biological descriptors of molecules that, when combined with conventional chemical descriptors, may considerably improve the accuracy and utility of computational approaches for predicting in vivo animal toxicity end points. PMID:20980217

  6. Independent data validation of an in vitro method for prediction of relative bioavailability of arsenic in contaminated soils

    EPA Science Inventory

    In vitro bioaccessibility assays (IVBA) estimate arsenic (As) relative bioavailability (RBA) in contaminated soils to improve the accuracy of site-specific human exposure assessments and risk calculations. For an IVBA assay to gain acceptance for use in risk assessment, it must ...

  7. Linearization of the bradford protein assay.

    PubMed

    Ernst, Orna; Zor, Tsaffrir

    2010-04-12

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, the ratio of the absorbance measurements at 590 nm and 450 nm is strictly linear with protein concentration. This simple procedure increases the accuracy and improves the sensitivity of the assay about 10-fold, permitting quantification down to 50 ng of bovine serum albumin. Furthermore, the interference commonly introduced by detergents that are used to create the cell lysates is greatly reduced by the new protocol. A linear equation developed on the basis of mass action and Beer's law perfectly fits the experimental data.

  8. Evaluating the diagnostic accuracy of the Xpert MTB/RIF assay on bronchoalveolar lavage fluid: A retrospective study.

    PubMed

    Lu, Yanjun; Zhu, Yaowu; Shen, Na; Tian, Lei; Sun, Ziyong

    2018-02-08

    Limited data on the diagnostic accuracy of the Xpert MTB/RIF assay using bronchoalveolar lavage fluid from patients with suspected pulmonary tuberculosis (PTB) have been reported in China. Therefore, a retrospective study was designed to evaluate the diagnostic accuracy of this assay. Clinical, radiological, and microbiological characteristics of 238 patients with suspected PTB were reviewed retrospectively. The sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of active PTB were calculated for the Xpert MTB/RIF assay using TB culture or final diagnosis based on clinical and radiological evaluation as the reference standard. The sensitivity and specificity of the Xpert MTB/RIF assay were 84.5% and 98.9%, respectively, and those for smear microscopy were 36.2% and 100%, respectively, when compared to the culture method. However, compared with the sensitivity and specificity of final diagnosis based on clinical and radiological evaluation, the sensitivity and specificity of the assay were 72.9% and 98.7%, respectively, which were significantly higher than those for smear microscopy. The Xpert MTB/RIF assay on bronchoalveolar lavage fluid could serve as an additional rapid diagnostic tool for PTB in a high TB-burden country and improve the time to TB treatment initiation in patients with PTB. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  9. A testing strategy to predict risk for drug-induced liver injury in humans using high-content screen assays and the 'rule-of-two' model.

    PubMed

    Chen, Minjun; Tung, Chun-Wei; Shi, Qiang; Guo, Lei; Shi, Leming; Fang, Hong; Borlak, Jürgen; Tong, Weida

    2014-07-01

    Drug-induced liver injury (DILI) is a major cause of drug failures in both the preclinical and clinical phase. Consequently, improving prediction of DILI at an early stage of drug discovery will reduce the potential failures in the subsequent drug development program. In this regard, high-content screening (HCS) assays are considered as a promising strategy for the study of DILI; however, the predictive performance of HCS assays is frequently insufficient. In the present study, a new testing strategy was developed to improve DILI prediction by employing in vitro assays that was combined with the RO2 model (i.e., 'rule-of-two' defined by daily dose ≥100 mg/day & logP ≥3). The RO2 model was derived from the observation that high daily doses and lipophilicity of an oral medication were associated with significant DILI risk in humans. In the developed testing strategy, the RO2 model was used for the rational selection of candidates for HCS assays, and only the negatives predicted by the RO2 model were further investigated by HCS. Subsequently, the effects of drug treatment on cell loss, nuclear size, DNA damage/fragmentation, apoptosis, lysosomal mass, mitochondrial membrane potential, and steatosis were studied in cultures of primary rat hepatocytes. Using a set of 70 drugs with clear evidence of clinically relevant DILI, the testing strategy improved the accuracies by 10 % and reduced the number of drugs requiring experimental assessment by approximately 20 %, as compared to the HCS assay alone. Moreover, the testing strategy was further validated by including published data (Cosgrove et al. in Toxicol Appl Pharmacol 237:317-330, 2009) on drug-cytokine-induced hepatotoxicity, which improved the accuracies by 7 %. Taken collectively, the proposed testing strategy can significantly improve the prediction of in vitro assays for detecting DILI liability in an early drug discovery phase.

  10. Tiered application of the neutral red release and EpiOcular™ assays for evaluating the eye irritation potential of agrochemical formulations.

    PubMed

    Settivari, Raja S; Amado, Ricardo Acosta; Corvaro, Marco; Visconti, Nicolo R; Kan, Lynn; Carney, Edward W; Boverhof, Darrell R; Gehen, Sean C

    2016-11-01

    Agrochemical formulations have been underrepresented in validation efforts for implementing alternative eye irritation approaches but represent a significant opportunity to reduce animal testing. This study assesses the utility of the neutral red release assay (NRR) and EpiOcular™ assay (EO) for predicting the eye irritation potential of 64 agrochemical formulations relative to Draize data. In the NRR, formulations with an NRR50 value ≤ 50 mg/mL were categorized as UN GHS Cat 1 and those >250 mg/mL were classified as UN GHS Non Classified (NC). The accuracy, sensitivity, and specificity were 78, 85 and 76% and 73, 85 and 61% for identifying UN GHS 1 and NC formulations, respectively. Specificity was poor for formulations with NRR50 > 50 to ≤250 mg/mL. The EO (ET-40 method) was explored to differentiate formulations that were UN GHS 1/2 and UN GHS NC. The EO resulted in accuracy, sensitivity, and specificity of 65%, 58% and 75% for identifying UN GHS NC formulations. To improve the overall performance, the assays were implemented using a tiered-approach where the NRR was run as a first-tier followed by the EO. The tiered-approach resulted in improved accuracy (75%) and balanced sensitivity (73%) and specificity (77%) for distinguishing between irritating and non-irritating agrochemical formulations. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Improving the sensitivity and accuracy of gamma activation analysis for the rapid determination of gold in mineral ores.

    PubMed

    Tickner, James; Ganly, Brianna; Lovric, Bojan; O'Dwyer, Joel

    2017-04-01

    Mining companies rely on chemical analysis methods to determine concentrations of gold in mineral ore samples. As gold is often mined commercially at concentrations around 1 part-per-million, it is necessary for any analysis method to provide good sensitivity as well as high absolute accuracy. We describe work to improve both the sensitivity and accuracy of the gamma activation analysis (GAA) method for gold. We present analysis results for several suites of ore samples and discuss the design of a GAA facility designed to replace conventional chemical assay in industrial applications. Copyright © 2017. Published by Elsevier Ltd.

  12. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident

    PubMed Central

    Semenova, Vera A.; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r2), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from −4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r2 = 0.952, slope = 1.02 and intercept = −0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. PMID:27814939

  13. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident.

    PubMed

    Semenova, Vera A; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r 2 ), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from -4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r 2  = 0.952, slope = 1.02 and intercept = -0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. Published by Elsevier Ltd.

  14. Analysis of the synthetic pyrethroids, permethrin and 1(R)-phenothrin, in grain using a monoclonal antibody-based test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skerritt, J.H.; Hill, A.S.; McAdam, D.P.

    1992-07-01

    A monoclonal antibody generated to the synthetic pyrethroid-related hapten, (3-phenoxybenzyl)-2,2-dimethylcyclopropane-1, 3-dicarboxylate-protein conjugate, was used to develop assays for determinations of permethrin and 1(R)-phenothrin in wheat grain and flour milling fractions. The earlier 3-h assay was simplified using two approaches. The antibody was directly conjugated to the enzyme horseradish peroxidase (HRP), which removes a separate incubation and washing step from the assay. Also, an assay has been developed using microwell-bound monoclonal antibody and a HRP-labeled 3-phenoxybenzoic acid derivative. These assay formats have advantages in increased sensitivity and, in the case of the latter assay, accuracy with grain and flour samples. Themore » most sensitive assay format could detect 1.5 ng/mL permethrin; 50% inhibition of antibody binding occurred at 10 ng/mL. These values corresponded to 75 and 500 ppb, respectively, in the original wheat sample. Methanol was the most effective pyrethroid extractant. Use of a simple cleanup procedure for ground grain extracts improved ELISA accuracy but could by omitted for screening purposes.« less

  15. Improving the sensitivity and specificity of a bioanalytical assay for the measurement of certolizumab pegol.

    PubMed

    Smeraglia, John; Silva, John-Paul; Jones, Kieran

    2017-08-01

    In order to evaluate placental transfer of certolizumab pegol (CZP), a more sensitive and selective bioanalytical assay was required to accurately measure low CZP concentrations in infant and umbilical cord blood. Results & methodology: A new electrochemiluminescence immunoassay was developed to measure CZP levels in human plasma. Validation experiments demonstrated improved selectivity (no matrix interference observed) and a detection range of 0.032-5.0 μg/ml. Accuracy and precision met acceptance criteria (mean total error ≤20.8%). Dilution linearity and sample stability were acceptable and sufficient to support the method. The electrochemiluminescence immunoassay was validated for measuring low CZP concentrations in human plasma. The method demonstrated a more than tenfold increase in sensitivity compared with previous assays, and improved selectivity for intact CZP.

  16. Integrative Approaches for Predicting in vivo Effects of Chemicals from their Structural Descriptors and the Results of Short-term Biological Assays

    PubMed Central

    Low, Yen S.; Sedykh, Alexander; Rusyn, Ivan; Tropsha, Alexander

    2017-01-01

    Cheminformatics approaches such as Quantitative Structure Activity Relationship (QSAR) modeling have been used traditionally for predicting chemical toxicity. In recent years, high throughput biological assays have been increasingly employed to elucidate mechanisms of chemical toxicity and predict toxic effects of chemicals in vivo. The data generated in such assays can be considered as biological descriptors of chemicals that can be combined with molecular descriptors and employed in QSAR modeling to improve the accuracy of toxicity prediction. In this review, we discuss several approaches for integrating chemical and biological data for predicting biological effects of chemicals in vivo and compare their performance across several data sets. We conclude that while no method consistently shows superior performance, the integrative approaches rank consistently among the best yet offer enriched interpretation of models over those built with either chemical or biological data alone. We discuss the outlook for such interdisciplinary methods and offer recommendations to further improve the accuracy and interpretability of computational models that predict chemical toxicity. PMID:24805064

  17. Bacteriophage-based assays for the rapid detection of rifampicin resistance in Mycobacterium tuberculosis: a meta-analysis.

    PubMed

    Pai, Madhukar; Kalantri, Shriprakash; Pascopella, Lisa; Riley, Lee W; Reingold, Arthur L

    2005-10-01

    To summarize, using meta-analysis, the accuracy of bacteriophage-based assays for the detection of rifampicin resistance in Mycobacterium tuberculosis. By searching multiple databases and sources we identified a total of 21 studies eligible for meta-analysis. Of these, 14 studies used phage amplification assays (including eight studies on the commercial FASTPlaque-TB kits), and seven used luciferase reporter phage (LRP) assays. Sensitivity, specificity, and agreement between phage assay and reference standard (e.g. agar proportion method or BACTEC 460) results were the main outcomes of interest. When performed on culture isolates (N=19 studies), phage assays appear to have relatively high sensitivity and specificity. Eleven of 19 (58%) studies reported sensitivity and specificity estimates > or =95%, and 13 of 19 (68%) studies reported > or =95% agreement with reference standard results. Specificity estimates were slightly lower and more variable than sensitivity; 5 of 19 (26%) studies reported specificity <90%. Only two studies performed phage assays directly on sputum specimens; although one study reported sensitivity and specificity of 100 and 99%, respectively, another reported sensitivity of 86% and specificity of 73%. Current evidence is largely restricted to the use of phage assays for the detection of rifampicin resistance in culture isolates. When used on culture isolates, these assays appear to have high sensitivity, but variable and slightly lower specificity. In contrast, evidence is lacking on the accuracy of these assays when they are directly applied to sputum specimens. If phage-based assays can be directly used on clinical specimens and if they are shown to have high accuracy, they have the potential to improve the diagnosis of MDR-TB. However, before phage assays can be successfully used in routine practice, several concerns have to be addressed, including unexplained false positives in some studies, potential for contamination and indeterminate results.

  18. Development and validation of a liquid chromatography tandem mass spectrometry assay for the quantitation of a protein therapeutic in cynomolgus monkey serum.

    PubMed

    Zhao, Yue; Liu, Guowen; Angeles, Aida; Hamuro, Lora L; Trouba, Kevin J; Wang, Bonnie; Pillutla, Renuka C; DeSilva, Binodh S; Arnold, Mark E; Shen, Jim X

    2015-04-15

    We have developed and fully validated a fast and simple LC-MS/MS assay to quantitate a therapeutic protein BMS-A in cynomolgus monkey serum. Prior to trypsin digestion, a recently reported sample pretreatment method was applied to remove more than 95% of the total serum albumin and denature the proteins in the serum sample. The pretreatment procedure simplified the biological sample prior to digestion, improved digestion efficiency and reproducibility, and did not require reduction and alkylation. The denatured proteins were then digested with trypsin at 60 °C for 30 min and the tryptic peptides were chromatographically separated on an Acquity CSH column (2.1 mm × 50 mm, 1.7 μm) using gradient elution. One surrogate peptide was used for quantitation and another surrogate peptide was selected for confirmation. Two corresponding stable isotope labeled peptides were used to compensate variations during LC-MS detection. The linear analytical range of the assay was 0.50-500 μg/mL. The accuracy (%Dev) was within ± 5.4% and the total assay variation (%CV) was less than 12.0% for sample analysis. The validated method demonstrated good accuracy and precision and the application of the innovative albumin removal sample pretreatment method improved both assay sensitivity and robustness. The assay has been applied to a cynomolgus monkey toxicology study and the serum sample concentration data were in good agreement with data generated using a quantitative ligand-binding assay (LBA). The use of a confirmatory peptide, in addition to the quantitation peptide, ensured the integrity of the drug concentrations measured by the method. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Multiple calibrator measurements improve accuracy and stability estimates of automated assays.

    PubMed

    Akbas, Neval; Budd, Jeffrey R; Klee, George G

    2016-01-01

    The effects of combining multiple calibrations on assay accuracy (bias) and measurement of calibration stability were investigated for total triiodothyronine (TT3), vitamin B12 and luteinizing hormone (LH) using Beckman Coulter's Access 2 analyzer. Three calibration procedures (CC1, CC2 and CC3) combined 12, 34 and 56 calibrator measurements over 1, 2, and 3 days. Bias was calculated between target values and average measured value over 3 consecutive days after calibration. Using regression analysis of calibrator measurements versus measurement date, calibration stability was determined as the maximum number of days before a calibrator measurement exceeded 5% tolerance limits. Competitive assays (TT3, vitamin B12) had positive time regression slopes, while sandwich assay (LH) had a negative slope. Bias values for TT3 were -2.49%, 1.49%, and -0.50% using CC1, CC2 and CC3 respectively, with calibrator stability of 32, 20, and 30 days. Bias values for vitamin B12 were 2.44%, 0.91%, and -0.50%, with calibrator stability of 4, 9, and 12 days. Bias values for LH were 2.26%, 1.44% and -0.29% with calibrator stability of >43, 39 and 36 days. Measured stability was more consistent across calibration procedures using percent change rather than difference from target: 26 days for TT3, 12 days for B12 and 31 days for LH. Averaging over multiple calibrations produced smaller bias, consistent with improved accuracy. Time regression slopes in percent change were unaffected by number of calibration measurements but calibrator stability measured from the target value was highly affected by the calibrator value at time zero.

  20. Accuracy of information on substance use recorded in medical charts of patients with intentional drug overdose.

    PubMed

    Tournier, Marie; Molimard, Mathieu; Titier, Karine; Cougnard, Audrey; Bégaud, Bernard; Gbikpi-Benissan, Georges; Verdoux, Hélène

    2007-07-30

    Psychoactive substance use is a risk factor for suicidal behavior and current intoxication increases the likelihood of serious intentional drug overdose (IDO). The objective was to assess the accuracy of information on substance use recorded in medical charts using toxicological assays as a reference in subjects admitted for IDO to an emergency department. Patients (n=1190) consecutively admitted for IDO were included. Information on substance use was recorded in routine practice by the emergency staff and toxicological assays (cannabis, opiate, buprenorphine, amphetamine/ecstasy, cocaine, LSD) were carried out in urine samples collected as part of routine management. The information on substance use was recorded in medical charts for 24.4% of subjects. A third of subjects (27.5%) were positive for toxicological assays. Recorded substance use allowed correct classification of nearly 80% of subjects. However, specificity (88.6%) was better than sensitivity (54.2%). Compared with toxicological assays, medical records allowed identification of only half of the subjects with current substance use. The usefulness of systematic toxicological assays during hospitalization for IDO should be assessed in further studies exploring whether such information allows medical management to be modified and contributes to improving prognosis.

  1. Development of a data-processing method based on Bayesian k-means clustering to discriminate aneugens and clastogens in a high-content micronucleus assay.

    PubMed

    Huang, Z H; Li, N; Rao, K F; Liu, C T; Huang, Y; Ma, M; Wang, Z J

    2018-03-01

    Genotoxicants can be identified as aneugens and clastogens through a micronucleus (MN) assay. The current high-content screening-based MN assays usually discriminate an aneugen from a clastogen based on only one parameter, such as the MN size, intensity, or morphology, which yields low accuracies (70-84%) because each of these parameters may contribute to the results. Therefore, the development of an algorithm that can synthesize high-dimensionality data to attain comparative results is important. To improve the automation and accuracy of detection using the current parameter-based mode of action (MoA), the MN MoA signatures of 20 chemicals were systematically recruited in this study to develop an algorithm. The results of the algorithm showed very good agreement (93.58%) between the prediction and reality, indicating that the proposed algorithm is a validated analytical platform for the rapid and objective acquisition of genotoxic MoA messages.

  2. Cross-Sectional HIV Incidence Estimation in HIV Prevention Research

    PubMed Central

    Brookmeyer, Ron; Laeyendecker, Oliver; Donnell, Deborah; Eshleman, Susan H.

    2013-01-01

    Accurate methods for estimating HIV incidence from cross-sectional samples would have great utility in prevention research. This report describes recent improvements in cross-sectional methods that significantly improve their accuracy. These improvements are based on the use of multiple biomarkers to identify recent HIV infections. These multi-assay algorithms (MAAs) use assays in a hierarchical approach for testing that minimizes the effort and cost of incidence estimation. These MAAs do not require mathematical adjustments for accurate estimation of the incidence rates in study populations in the year prior to sample collection. MAAs provide a practical, accurate, and cost-effective approach for cross-sectional HIV incidence estimation that can be used for HIV prevention research and global epidemic monitoring. PMID:23764641

  3. Clinical pharmacology quality assurance program: models for longitudinal analysis of antiretroviral proficiency testing for international laboratories.

    PubMed

    DiFrancesco, Robin; Rosenkranz, Susan L; Taylor, Charlene R; Pande, Poonam G; Siminski, Suzanne M; Jenny, Richard W; Morse, Gene D

    2013-10-01

    Among National Institutes of Health HIV Research Networks conducting multicenter trials, samples from protocols that span several years are analyzed at multiple clinical pharmacology laboratories (CPLs) for multiple antiretrovirals. Drug assay data are, in turn, entered into study-specific data sets that are used for pharmacokinetic analyses, merged to conduct cross-protocol pharmacokinetic analysis, and integrated with pharmacogenomics research to investigate pharmacokinetic-pharmacogenetic associations. The CPLs participate in a semiannual proficiency testing (PT) program implemented by the Clinical Pharmacology Quality Assurance program. Using results from multiple PT rounds, longitudinal analyses of recovery are reflective of accuracy and precision within/across laboratories. The objectives of this longitudinal analysis of PT across multiple CPLs were to develop and test statistical models that longitudinally: (1) assess the precision and accuracy of concentrations reported by individual CPLs and (2) determine factors associated with round-specific and long-term assay accuracy, precision, and bias using a new regression model. A measure of absolute recovery is explored as a simultaneous measure of accuracy and precision. Overall, the analysis outcomes assured 97% accuracy (±20% of the final target concentration of all (21) drug concentration results reported for clinical trial samples by multiple CPLs). Using the Clinical Laboratory Improvement Act acceptance of meeting criteria for ≥2/3 consecutive rounds, all 10 laboratories that participated in 3 or more rounds per analyte maintained Clinical Laboratory Improvement Act proficiency. Significant associations were present between magnitude of error and CPL (Kruskal-Wallis P < 0.001) and antiretroviral (Kruskal-Wallis P < 0.001).

  4. Improved age determination of blood and teeth samples using a selected set of DNA methylation markers

    PubMed Central

    Kamalandua, Aubeline

    2015-01-01

    Age estimation from DNA methylation markers has seen an exponential growth of interest, not in the least from forensic scientists. The current published assays, however, can still be improved by lowering the number of markers in the assay and by providing more accurate models to predict chronological age. From the published literature we selected 4 age-associated genes (ASPA, PDE4C, ELOVL2, and EDARADD) and determined CpG methylation levels from 206 blood samples of both deceased and living individuals (age range: 0–91 years). This data was subsequently used to compare prediction accuracy with both linear and non-linear regression models. A quadratic regression model in which the methylation levels of ELOVL2 were squared showed the highest accuracy with a Mean Absolute Deviation (MAD) between chronological age and predicted age of 3.75 years and an adjusted R2 of 0.95. No difference in accuracy was observed for samples obtained either from living and deceased individuals or between the 2 genders. In addition, 29 teeth from different individuals (age range: 19–70 years) were analyzed using the same set of markers resulting in a MAD of 4.86 years and an adjusted R2 of 0.74. Cross validation of the results obtained from blood samples demonstrated the robustness and reproducibility of the assay. In conclusion, the set of 4 CpG DNA methylation markers is capable of producing highly accurate age predictions for blood samples from deceased and living individuals PMID:26280308

  5. CON4EI: Short Time Exposure (STE) test method for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Adriaens, E; Willoughby, J A; Meyer, B R; Blakeman, L C; Alépée, N; Fochtman, P; Guest, R; Kandarova, H; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium was developed to assess the reliability of eight in vitro test methods and establish an optimal tiered-testing strategy. One assay selected was the Short Time Exposure (STE) assay. This assay measures the viability of SIRC rabbit corneal cells after 5min exposure to 5% and 0.05% solutions of test material, and is capable of categorizing of Category 1 and No Category chemicals. The accuracy of the STE test method to identify Cat 1 chemicals was 61.3% with 23.7% sensitivity and 95.2% specificity. If non-soluble chemicals and unqualified results were excluded, the performance to identify Cat 1 chemicals remained similar (accuracy 62.2% with 22.7% sensitivity and 100% specificity). The accuracy of the STE test method to identify No Cat chemicals was 72.5% with 66.2% sensitivity and 100% specificity. Excluding highly volatile chemicals, non-surfactant solids and non-qualified results resulted in an important improvement of the performance of the STE test method (accuracy 96.2% with 81.8% sensitivity and 100% specificity). Furthermore, it seems that solids are more difficult to test in the STE, 71.4% of the solids resulted in unqualified results (solubility issues and/or high variation between independent runs) whereas for liquids 13.2% of the results were not qualified, supporting the restriction of the test method regarding the testing of solids. Copyright © 2017. Published by Elsevier Ltd.

  6. Calorimetry of low mass Pu239 items

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cremers, Teresa L; Sampson, Thomas E

    2010-01-01

    Calorimetric assay has the reputation of providing the highest precision and accuracy of all nondestructive assay measurements. Unfortunately, non-destructive assay practitioners and measurement consumers often extend, inappropriately, the high precision and accuracy of calorimetric assay to very low mass items. One purpose of this document is to present more realistic expectations for the random uncertainties associated with calorimetric assay for weapons grade plutonium items with masses of 200 grams or less.

  7. A high-throughput assay for DNA topoisomerases and other enzymes, based on DNA triplex formation.

    PubMed

    Burrell, Matthew R; Burton, Nicolas P; Maxwell, Anthony

    2010-01-01

    We have developed a rapid, high-throughput assay for measuring the catalytic activity (DNA supercoiling or relaxation) of topoisomerase enzymes that is also capable of monitoring the activity of other enzymes that alter the topology of DNA. The assay utilises intermolecular triplex formation to resolve supercoiled and relaxed forms of DNA, the principle being the greater efficiency of a negatively supercoiled plasmid to form an intermolecular triplex with an immobilised oligonucleotide than the relaxed form. The assay provides a number of advantages over the standard gel-based methods, including greater speed of analysis, reduced sample handling, better quantitation and improved reliability and accuracy of output data. The assay is performed in microtitre plates and can be adapted to high-throughput screening of libraries of potential inhibitors of topoisomerases including bacterial DNA gyrase.

  8. Functional DNA quantification guides accurate next-generation sequencing mutation detection in formalin-fixed, paraffin-embedded tumor biopsies

    PubMed Central

    2013-01-01

    The formalin-fixed, paraffin-embedded (FFPE) biopsy is a challenging sample for molecular assays such as targeted next-generation sequencing (NGS). We compared three methods for FFPE DNA quantification, including a novel PCR assay (‘QFI-PCR’) that measures the absolute copy number of amplifiable DNA, across 165 residual clinical specimens. The results reveal the limitations of commonly used approaches, and demonstrate the value of an integrated workflow using QFI-PCR to improve the accuracy of NGS mutation detection and guide changes in input that can rescue low quality FFPE DNA. These findings address a growing need for improved quality measures in NGS-based patient testing. PMID:24001039

  9. Widespread Nanoparticle-Assay Interference: Implications for Nanotoxicity Testing

    PubMed Central

    Ong, Kimberly J.; MacCormack, Tyson J.; Clark, Rhett J.; Ede, James D.; Ortega, Van A.; Felix, Lindsey C.; Dang, Michael K. M.; Ma, Guibin; Fenniri, Hicham; Veinot, Jonathan G. C.; Goss, Greg G.

    2014-01-01

    The evaluation of engineered nanomaterial safety has been hindered by conflicting reports demonstrating differential degrees of toxicity with the same nanoparticles. The unique properties of these materials increase the likelihood that they will interfere with analytical techniques, which may contribute to this phenomenon. We tested the potential for: 1) nanoparticle intrinsic fluorescence/absorbance, 2) interactions between nanoparticles and assay components, and 3) the effects of adding both nanoparticles and analytes to an assay, to interfere with the accurate assessment of toxicity. Silicon, cadmium selenide, titanium dioxide, and helical rosette nanotubes each affected at least one of the six assays tested, resulting in either substantial over- or under-estimations of toxicity. Simulation of realistic assay conditions revealed that interference could not be predicted solely by interactions between nanoparticles and assay components. Moreover, the nature and degree of interference cannot be predicted solely based on our current understanding of nanomaterial behaviour. A literature survey indicated that ca. 95% of papers from 2010 using biochemical techniques to assess nanotoxicity did not account for potential interference of nanoparticles, and this number had not substantially improved in 2012. We provide guidance on avoiding and/or controlling for such interference to improve the accuracy of nanotoxicity assessments. PMID:24618833

  10. Use of diagnostic accuracy as a metric for evaluating laboratory proficiency with microarray assays using mixed-tissue RNA reference samples.

    PubMed

    Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L

    2008-11-01

    Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.

  11. Accuracy of a prey-specific DNA assay and a generic prey-immunomarking assay for detecting predation

    USDA-ARS?s Scientific Manuscript database

    1. Predator gut examinations are useful for detecting arthropod predation events. Here, the accuracy and reproducibility of two different types of gut assays are tested on various predator species that consumed an immature lacewing, Chrysoperla carnea (Stephens), that was externally labelled with ra...

  12. Use of in Vitro HTS-Derived Concentration-Response Data as Biological Descriptors Improves the Accuracy of QSAR Models of in Vivo Toxicity

    EPA Science Inventory

    Background: Quantitative high-throughput screening (qHTS) assays are increasingly being employed to inform chemical hazard identification. Hundreds of chemicals have been tested in dozens of cell lines across extensive concentration ranges by the National Toxicology Program in co...

  13. Development of Fully Automated Low-Cost Immunoassay System for Research Applications.

    PubMed

    Wang, Guochun; Das, Champak; Ledden, Bradley; Sun, Qian; Nguyen, Chien

    2017-10-01

    Enzyme-linked immunosorbent assay (ELISA) automation for routine operation in a small research environment would be very attractive. A portable fully automated low-cost immunoassay system was designed, developed, and evaluated with several protein analytes. It features disposable capillary columns as the reaction sites and uses real-time calibration for improved accuracy. It reduces the overall assay time to less than 75 min with the ability of easy adaptation of new testing targets. The running cost is extremely low due to the nature of automation, as well as reduced material requirements. Details about system configuration, components selection, disposable fabrication, system assembly, and operation are reported. The performance of the system was initially established with a rabbit immunoglobulin G (IgG) assay, and an example of assay adaptation with an interleukin 6 (IL6) assay is shown. This system is ideal for research use, but could work for broader testing applications with further optimization.

  14. Accuracy of Blood Loss Measurement during Cesarean Delivery.

    PubMed

    Doctorvaladan, Sahar V; Jelks, Andrea T; Hsieh, Eric W; Thurer, Robert L; Zakowski, Mark I; Lagrew, David C

    2017-04-01

    Objective  This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design  In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland-Altman method. Results  Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R 2  = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R 2  = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R 2  = 0.304). Conclusion  During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes.

  15. Accuracy of Blood Loss Measurement during Cesarean Delivery

    PubMed Central

    Doctorvaladan, Sahar V.; Jelks, Andrea T.; Hsieh, Eric W.; Thurer, Robert L.; Zakowski, Mark I.; Lagrew, David C.

    2017-01-01

    Objective This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland–Altman method. Results Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R2 = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R2 = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R2 = 0.304). Conclusion During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes. PMID:28497007

  16. Evaluation of HER-2/neu gene amplification and overexpression: comparison of frequently used assay methods in a molecularly characterized cohort of breast cancer specimens.

    PubMed

    Press, Michael F; Slamon, Dennis J; Flom, Kerry J; Park, Jinha; Zhou, Jian-Yuan; Bernstein, Leslie

    2002-07-15

    To compare and evaluate HER-2/neu clinical assay methods. One hundred seventeen breast cancer specimens with known HER-2/neu amplification and overexpression status were assayed with four different immunohistochemical assays and two different fluorescence in situ hybridization (FISH) assays. The accuracy of the FISH assays for HER-2/neu gene amplification was high, 97.4% for the Vysis PathVision assay (Vysis, Inc, Downers Grove, IL) and 95.7% for the the Ventana INFORM assay (Ventana, Medical Systems, Inc, Tucson, AZ). The immunohistochemical assay with the highest accuracy for HER-2/neu overexpression was obtained with R60 polyclonal antibody (96.6%), followed by immunohistochemical assays performed with 10H8 monoclonal antibody (95.7%), the Ventana CB11 monoclonal antibody (89.7%), and the DAKO HercepTest (88.9%; Dako, Corp, Carpinteria, CA). Only the sensitivities, and therefore, overall accuracy, of the DAKO Herceptest and Ventana CB11 immunohistochemical assays were significantly different from the more sensitive FISH assay. Based on these findings, the FISH assays were highly accurate, with immunohistochemical assays performed with R60 and 10H8 nearly as accurate. The DAKO HercepTest and the Ventana CB11 immunohistochemical assay were statistically significantly different from the Vysis FISH assay in evaluating these previously molecularly characterized breast cancer specimens.

  17. Profile of Instrumentation Laboratory's HemosIL® AcuStar HIT-Ab(PF4-H) assay for diagnosis of heparin-induced thrombocytopenia.

    PubMed

    Nagler, Michael; Cuker, Adam

    2017-05-01

    Immunoassays play an essential role in the diagnosis of heparin-induced thrombocytopenia (HIT). The objective of this article is to review HemosIL® AcuStar HIT-Ab(PF4-H) (Instrumentation Laboratory, Bedford, MA, USA), a new chemiluminescent immunoassay for HIT. Areas covered: The authors searched the published literature for evaluation studies of HemosIL® AcuStar HIT-Ab(PF4-H) and sought information from the manufacturer. In this paper, the authors discuss the analytical principle and technical aspects of the assay; describe its diagnostic performance in validation studies; report on its reproducibility, cost-effectiveness, and regulatory status; and discuss the implications of the assay on clinical practice and means of integrating it in diagnostic pathways. HemosIL® AcuStar HIT-Ab(PF4-H) is compared with other rapid assays and widely used enzyme-linked immunoassays for the diagnosis of HIT. Expert commentary: HemosIL® AcuStar HIT-Ab(PF4-H) is automatable, can be performed 24 h per day, offers a rapid turnaround time, and appears to have favorable diagnostic accuracy, particularly at thresholds above that listed in the label. These advantages could lead to improved patient outcomes through rapid provision of results at the point of care, enhancing the accuracy of initial diagnosis.

  18. HPLC-high-resolution mass spectrometry with polarity switching for increasing throughput of human in vitro cocktail drug-drug interaction assay.

    PubMed

    Ramanathan, Ragu; Ghosal, Anima; Ramanathan, Lakshmi; Comstock, Kate; Shen, Helen; Ramanathan, Dil

    2018-05-01

    Evaluation of HPLC-high-resolution mass spectrometry (HPLC-HRMS) full scan with polarity switching for increasing throughput of human in vitro cocktail drug-drug interaction assay. Microsomal incubates were analyzed using a high resolution and high mass accuracy Q-Exactive mass spectrometer to collect integrated qualitative and quantitative (qual/quant) data. Within assay, positive-to-negative polarity switching HPLC-HRMS method allowed quantification of eight and two probe compounds in the positive and negative ionization modes, respectively, while monitoring for LOR and its metabolites. LOR-inhibited CYP2C19 and showed higher activity for CYP2D6, CYP2E1 and CYP3A4. Overall, LC-HRMS-based nontargeted full scan quantitation allowed to improve the throughput of the in vitro cocktail drug-drug interaction assay.

  19. Comparison of Established and Emerging Biodosimetry Assays

    PubMed Central

    Rothkamm, K.; Beinke, C.; Romm, H.; Badie, C.; Balagurunathan, Y.; Barnard, S.; Bernard, N.; Boulay-Greene, H.; Brengues, M.; De Amicis, A.; De Sanctis, S.; Greither, R.; Herodin, F.; Jones, A.; Kabacik, S.; Knie, T.; Kulka, U.; Lista, F.; Martigne, P.; Missel, A.; Moquet, J.; Oestreicher, U.; Peinnequin, A.; Poyot, T.; Roessler, U.; Scherthan, H.; Terbrueggen, B.; Thierens, H.; Valente, M.; Vral, A.; Zenhausern, F.; Meineke, V.; Braselmann, H.; Abend, M.

    2014-01-01

    Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3–0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5–4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools. PMID:23862692

  20. Evaluation of a Rapid and Completely Automated Real-Time Reverse Transcriptase PCR Assay for Diagnosis of Enteroviral Meningitis▿

    PubMed Central

    Nolte, Frederick S.; Rogers, Beverly B.; Tang, Yi-Wei; Oberste, M. Steven; Robinson, Christine C.; Kehl, K. Sue; Rand, Kenneth A.; Rotbart, Harley A.; Romero, Jose R.; Nyquist, Ann-Christine; Persing, David H.

    2011-01-01

    Nucleic acid amplification tests (NAATs) for enterovirus RNA in cerebrospinal fluid (CSF) have emerged as the new gold standard for diagnosis of enteroviral meningitis, and their use can improve the management and decrease the costs for caring for children with enteroviral meningitis. The Xpert EV assay (Cepheid, Sunnyvale, CA) is a rapid, fully automated real-time PCR test for the detection of enterovirus RNA that was approved by the U.S. Food and Drug Administration for in vitro diagnostic use in March 2007. In this multicenter trial we established the clinical performance characteristics of the Xpert EV assay in patients presenting with meningitis symptoms relative to clinical truth. Clinical truth for enteroviral meningitis was defined as clinical evidence of meningitis, the absence of another detectable pathogen in CSF, and detection of enterovirus in CSF either by two reference NAATs or by viral culture. A total of 199 prospectively and 235 retrospectively collected specimens were eligible for inclusion in this study. The overall prevalence of enteroviral meningitis was 26.04%. The Xpert EV assay had a sensitivity of 94.69% (90% confidence interval [CI] = 89.79 to 97.66%), specificity of 100% (90% CI = 99.07 to 100%), positive predictive value of 100%, negative predictive value of 98.17, and an accuracy of 98.62% relative to clinical truth. The Xpert EV assay demonstrated a high degree of accuracy for diagnosis of enteroviral meningitis. The simplicity and on-demand capability of the Xpert EV assay should prove to be a valuable adjunct to the evaluation of suspected meningitis cases. PMID:21159942

  1. Evaluation of a rapid and completely automated real-time reverse transcriptase PCR assay for diagnosis of enteroviral meningitis.

    PubMed

    Nolte, Frederick S; Rogers, Beverly B; Tang, Yi-Wei; Oberste, M Steven; Robinson, Christine C; Kehl, K Sue; Rand, Kenneth A; Rotbart, Harley A; Romero, Jose R; Nyquist, Ann-Christine; Persing, David H

    2011-02-01

    Nucleic acid amplification tests (NAATs) for enterovirus RNA in cerebrospinal fluid (CSF) have emerged as the new gold standard for diagnosis of enteroviral meningitis, and their use can improve the management and decrease the costs for caring for children with enteroviral meningitis. The Xpert EV assay (Cepheid, Sunnyvale, CA) is a rapid, fully automated real-time PCR test for the detection of enterovirus RNA that was approved by the U.S. Food and Drug Administration for in vitro diagnostic use in March 2007. In this multicenter trial we established the clinical performance characteristics of the Xpert EV assay in patients presenting with meningitis symptoms relative to clinical truth. Clinical truth for enteroviral meningitis was defined as clinical evidence of meningitis, the absence of another detectable pathogen in CSF, and detection of enterovirus in CSF either by two reference NAATs or by viral culture. A total of 199 prospectively and 235 retrospectively collected specimens were eligible for inclusion in this study. The overall prevalence of enteroviral meningitis was 26.04%. The Xpert EV assay had a sensitivity of 94.69% (90% confidence interval [CI] = 89.79 to 97.66%), specificity of 100% (90% CI = 99.07 to 100%), positive predictive value of 100%, negative predictive value of 98.17, and an accuracy of 98.62% relative to clinical truth. The Xpert EV assay demonstrated a high degree of accuracy for diagnosis of enteroviral meningitis. The simplicity and on-demand capability of the Xpert EV assay should prove to be a valuable adjunct to the evaluation of suspected meningitis cases.

  2. Dual-color plasmonic enzyme-linked immunosorbent assay based on enzyme-mediated etching of Au nanoparticles

    NASA Astrophysics Data System (ADS)

    Guo, Longhua; Xu, Shaohua; Ma, Xiaoming; Qiu, Bin; Lin, Zhenyu; Chen, Guonan

    2016-09-01

    Colorimetric enzyme-linked immunosorbent assay utilizing 3‧-3-5‧-5-tetramethylbenzidine(TMB) as the chromogenic substrate has been widely used in the hospital for the detection of all kinds of disease biomarkers. Herein, we demonstrate a strategy to change this single-color display into dual-color responses to improve the accuracy of visual inspection. Our investigation firstly reveals that oxidation state of 3‧-3-5‧-5-tetramethylbenzidine (TMB2+) can quantitatively etch gold nanoparticles. Therefore, the incorporation of gold nanoparticles into a commercial TMB-based ELISA kit could generate dual-color responses: the solution color varied gradually from wine red (absorption peak located at ~530 nm) to colorless, and then from colorless to yellow (absorption peak located at ~450 nm) with the increase amount of targets. These dual-color responses effectively improved the sensitivity as well as the accuracy of visual inspection. For example, the proposed dual-color plasmonic ELISA is demonstrated for the detection of prostate-specific antigen (PSA) in human serum with a visual limit of detection (LOD) as low as 0.0093 ng/mL.

  3. Predicting phenotype from genotype: Improving accuracy through more robust experimental and computational modeling

    PubMed Central

    Gallion, Jonathan; Koire, Amanda; Katsonis, Panagiotis; Schoenegge, Anne‐Marie; Bouvier, Michel

    2017-01-01

    Abstract Computational prediction yields efficient and scalable initial assessments of how variants of unknown significance may affect human health. However, when discrepancies between these predictions and direct experimental measurements of functional impact arise, inaccurate computational predictions are frequently assumed as the source. Here, we present a methodological analysis indicating that shortcomings in both computational and biological data can contribute to these disagreements. We demonstrate that incomplete assaying of multifunctional proteins can affect the strength of correlations between prediction and experiments; a variant's full impact on function is better quantified by considering multiple assays that probe an ensemble of protein functions. Additionally, many variants predictions are sensitive to protein alignment construction and can be customized to maximize relevance of predictions to a specific experimental question. We conclude that inconsistencies between computation and experiment can often be attributed to the fact that they do not test identical hypotheses. Aligning the design of the computational input with the design of the experimental output will require cooperation between computational and biological scientists, but will also lead to improved estimations of computational prediction accuracy and a better understanding of the genotype–phenotype relationship. PMID:28230923

  4. Predicting phenotype from genotype: Improving accuracy through more robust experimental and computational modeling.

    PubMed

    Gallion, Jonathan; Koire, Amanda; Katsonis, Panagiotis; Schoenegge, Anne-Marie; Bouvier, Michel; Lichtarge, Olivier

    2017-05-01

    Computational prediction yields efficient and scalable initial assessments of how variants of unknown significance may affect human health. However, when discrepancies between these predictions and direct experimental measurements of functional impact arise, inaccurate computational predictions are frequently assumed as the source. Here, we present a methodological analysis indicating that shortcomings in both computational and biological data can contribute to these disagreements. We demonstrate that incomplete assaying of multifunctional proteins can affect the strength of correlations between prediction and experiments; a variant's full impact on function is better quantified by considering multiple assays that probe an ensemble of protein functions. Additionally, many variants predictions are sensitive to protein alignment construction and can be customized to maximize relevance of predictions to a specific experimental question. We conclude that inconsistencies between computation and experiment can often be attributed to the fact that they do not test identical hypotheses. Aligning the design of the computational input with the design of the experimental output will require cooperation between computational and biological scientists, but will also lead to improved estimations of computational prediction accuracy and a better understanding of the genotype-phenotype relationship. © 2017 The Authors. **Human Mutation published by Wiley Periodicals, Inc.

  5. Understanding and correcting for carbon nanotube interferences with a commercial LDH cytotoxicity assay.

    PubMed

    Wang, Gang; Zhang, Jianping; Dewilde, Abiche H; Pal, Anoop K; Bello, Dhimiter; Therrien, Joel M; Braunhut, Susan J; Marx, Kenneth A

    2012-09-28

    The lactate dehydrogenase (LDH) assay accurately quantifies cytotoxicity of chemicals via the measurement of LDH released from damaged cells. In the assay, LDH catalyzes formation of a reporter chromophore that can be quantified spectrophotometrically at its 490 nm peak, a standard assay, and related to the released LDH concentration. However, certain engineered nanomaterials have been reported to produce aberrant values, resulting in inaccurate assessment of toxicity as measured by LDH levels in media. We studied this effect spectroscopically by measuring unexpected changes in the complete visible spectrum of the product chromophore resulting from using either purified LDH or LDH from lysed cells in the presence of varying concentrations of single walled carbon nanotubes (SWCNTs) or carbon nanohorns (SWCNH-oxs). Basically, at constant LDH concentrations, the 490 nm product peak decreased with increasing carbon nanotube concentration, while the 580 nm peak increased to a lesser extent and the maximum absorbing wavelength increased. The product chromophore spectrum was altered in different ways by potential interactions with a number of components in the reaction mixture including: BSA, LDH, SWCNTs, SWCNT-oxs, or various combinations of these species. We propose to improve the accuracy of the LDH assay when evaluated in the presence of varying concentrations of these carbon nanostructures by use of both the 490 and 580 nm peak absorbances combined via regression analysis. Our results indicate that molecular probes of cytotoxicity must be assessed individually for accuracy in the presence of engineered nanomaterials. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. A Host-Based RT-PCR Gene Expression Signature to Identify Acute Respiratory Viral Infection

    PubMed Central

    Zaas, Aimee K.; Burke, Thomas; Chen, Minhua; McClain, Micah; Nicholson, Bradly; Veldman, Timothy; Tsalik, Ephraim L.; Fowler, Vance; Rivers, Emanuel P.; Otero, Ronny; Kingsmore, Stephen F.; Voora, Deepak; Lucas, Joseph; Hero, Alfred O.; Carin, Lawrence; Woods, Christopher W.; Ginsburg, Geoffrey S.

    2014-01-01

    Improved ways to diagnose acute respiratory viral infections could decrease inappropriate antibacterial use and serve as a vital triage mechanism in the event of a potential viral pandemic. Measurement of the host response to infection is an alternative to pathogen-based diagnostic testing and may improve diagnostic accuracy. We have developed a host-based assay with a reverse transcription polymerase chain reaction (RT-PCR) TaqMan low-density array (TLDA) platform for classifying respiratory viral infection. We developed the assay using two cohorts experimentally infected with influenza A H3N2/Wisconsin or influenza A H1N1/Brisbane, and validated the assay in a sample of adults presenting to the emergency department with fever (n = 102) and in healthy volunteers (n = 41). Peripheral blood RNA samples were obtained from individuals who underwent experimental viral challenge or who presented to the emergency department and had microbiologically proven viral respiratory infection or systemic bacterial infection. The selected gene set on the RT-PCR TLDA assay classified participants with experimentally induced influenza H3N2 and H1N1 infection with 100 and 87% accuracy, respectively. We validated this host gene expression signature in a cohort of 102 individuals arriving at the emergency department. The sensitivity of the RT-PCR test was 89% [95% confidence interval (CI), 72 to 98%], and the specificity was 94% (95% CI, 86 to 99%). These results show that RT-PCR–based detection of a host gene expression signature can classify individuals with respiratory viral infection and sets the stage for prospective evaluation of this diagnostic approach in a clinical setting. PMID:24048524

  7. Test battery with the human cell line activation test, direct peptide reactivity assay and DEREK based on a 139 chemical data set for predicting skin sensitizing potential and potency of chemicals.

    PubMed

    Takenouchi, Osamu; Fukui, Shiho; Okamoto, Kenji; Kurotani, Satoru; Imai, Noriyasu; Fujishiro, Miyuki; Kyotani, Daiki; Kato, Yoshinao; Kasahara, Toshihiko; Fujita, Masaharu; Toyoda, Akemi; Sekiya, Daisuke; Watanabe, Shinichi; Seto, Hirokazu; Hirota, Morihiko; Ashikaga, Takao; Miyazawa, Masaaki

    2015-11-01

    To develop a testing strategy incorporating the human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA) and DEREK, we created an expanded data set of 139 chemicals (102 sensitizers and 37 non-sensitizers) by combining the existing data set of 101 chemicals through the collaborative projects of Japan Cosmetic Industry Association. Of the additional 38 chemicals, 15 chemicals with relatively low water solubility (log Kow > 3.5) were selected to clarify the limitation of testing strategies regarding the lipophilic chemicals. Predictivities of the h-CLAT, DPRA and DEREK, and the combinations thereof were evaluated by comparison to results of the local lymph node assay. When evaluating 139 chemicals using combinations of three methods based on integrated testing strategy (ITS) concept (ITS-based test battery) and a sequential testing strategy (STS) weighing the predictive performance of the h-CLAT and DPRA, overall similar predictivities were found as before on the 101 chemical data set. An analysis of false negative chemicals suggested a major limitation of our strategies was the testing of low water-soluble chemicals. When excluded the negative results for chemicals with log Kow > 3.5, the sensitivity and accuracy of ITS improved to 97% (91 of 94 chemicals) and 89% (114 of 128). Likewise, the sensitivity and accuracy of STS to 98% (92 of 94) and 85% (111 of 129). Moreover, the ITS and STS also showed good correlation with local lymph node assay on three potency classifications, yielding accuracies of 74% (ITS) and 73% (STS). Thus, the inclusion of log Kow in analysis could give both strategies a higher predictive performance. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Development and validation of an LC-MS/MS method for quantification of cyclic guanosine 3',5'-monophosphate (cGMP) in clinical applications: a comparison with a EIA method.

    PubMed

    Zhang, Yanhua; Dufield, Dawn; Klover, Jon; Li, Wenlin; Szekely-Klepser, Gabriella; Lepsy, Christopher; Sadagopan, Nalini

    2009-02-15

    An LC-MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3',5'-monophosphate (cGMP) in human plasma. The LC-MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC-MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, (13)C(10),(15)N(5)-cGMP, which was biosynthesized in-house, was used in the LC-MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6-10.1% CV and -3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6-8.1% CV and -2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9-27.1% CV and -4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1-39.5% CV and -30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R(2)=0.197, P=0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5-20ng/mL. The LC-MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.

  9. A simple fluorescence-based assay for quantification of the Toll-Like Receptor agonist E6020 in vaccine formulations.

    PubMed

    Pollet, Jeroen; Versteeg, Leroy; Rezende, Wanderson; Strych, Ulrich; Gusovsky, Fabian; Hotez, Peter J; Bottazzi, Maria Elena

    2017-03-07

    Despite the generally accepted immunostimulatory effect of Toll-Like Receptor 4 (TLR4) agonists and their value as vaccine adjuvants, there remains a demand for fast and easy quantification assays for these TLR4 agonists in order to accelerate and improve vaccine formulation studies. A new medium-throughput method was developed for the quantification of the TLR4 agonist, E6020, independent of the formulation composition. The assay uses a fluorescent hydrazide (DCCH) to label the synthetic lipopolysaccharide (LPS) analog E6020 through its diketone groups. This novel, low-cost, and fluorescence based assay may obviate the need for traditional approaches that primarily rely on Fourier transform infrared spectroscopy (FTIR) or mass spectrometry. The experiments were performed in a wide diversity of vaccine formulations containing E6020 to assess method robustness and accuracy. The assay was also expanded to evaluate the loading efficiency of E6020 in poly(lactic-co-glycolic acid) (PLGA) micro-particles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. High diagnostic accuracy of histone H4-IgG autoantibodies in systemic lupus erythematosus.

    PubMed

    Vordenbäumen, Stefan; Böhmer, Paloma; Brinks, Ralph; Fischer-Betz, Rebecca; Richter, Jutta; Bleck, Ellen; Rengers, Petra; Göhler, Heike; Zucht, Hans-Dieter; Budde, Petra; Schulz-Knappe, Peter; Schneider, Matthias

    2018-03-01

    Diagnosis of SLE relies on the detection of autoantibodies. We aimed to assess the diagnostic potential of histone H4 and H2A variant antibodies in SLE. IgG-autoantibodies to histones H4 (HIST1H4A), H2A type 2-A (HIST2H2AA3) and H2A type 2-C (HIST2H2AC) were measured along with a standard antibody (SA) set including SSA, SSB, Sm, U1-RNP and RPLP2 in a multiplex magnetic microsphere-based assay in 153 SLE patients [85% female, 41 (13.5) years] and 81 healthy controls [77% female, 43.3 (12.4) years]. Receiver operating characteristic analysis was performed to assess diagnostic performance of individual markers. Logistic regression analysis was performed on a random split of samples to determine the additional value of histone antibodies in comparison with SA by likelihood ratio test and determination of diagnostic accuracy in the remaining validation samples. Microsphere-based assay showed good interclass correlation (mean 0.85, range 0.73-0.99) and diagnostic performance in receiver operating characteristic analysis (area under the curve (AUC) range 84.8-93.2) compared with routine assay for SA parameters. HIST1H4A-IgG was the marker with the best individual diagnostic performance for SLE vs healthy (AUC 0.97, sensitivity 95% at 90% specificity). HIST1H4A-IgG was an independent significant predictor for the diagnosis of SLE in multivariate modelling (P < 0.0001), and significantly improved prediction of SLE over SA parameters alone (residual deviance 45.9 vs 97.1, P = 4.3 × 10-11). Diagnostic accuracy in the training and validation samples was 89 and 86% for SA, and 95 and 89% with the addition of HIST1H4A-IgG. HIST1H4A-IgG antibodies improve diagnostic accuracy for SLE vs healthy. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. [br]For Permissions, please email: journals.permissions@oup.com

  11. Quenching the firefly bioluminescence by various ions.

    PubMed

    Zhang, Huateng; Bai, Haixiu; Jiang, Tianyu; Ma, Zhao; Cheng, Yanna; Zhou, Yubin; Du, Lupei; Li, Minyong

    2016-02-01

    The luciferase reporter gene assay system is broadly applied in various biomedical aspects, including signaling pathway dissection, transcriptional activity analysis, and genetic toxicity testing. It significantly improves the experimental accuracy and reduces the experimental error by the addition of an internal control. In the current research, we discovered some specific ions that could selectively inhibit firefly luciferase while having a negligible effect on renilla luciferase in vitro in the dual-reporter gene assay. We showed that these ionic compounds had a high potential of being utilized as quench-and-activate reagents in the dual-reporter assay. Furthermore, results from kinetic studies on ion-mediated quenching effects indicated that different ions have distinct inhibition modes. Our study is anticipated to guide a more affordable design of quench-and-activate reagents in biomedicine and pharmaceutical analysis.

  12. Use of in Vitro HTS-Derived Concentration-Response Data as ...

    EPA Pesticide Factsheets

    Background: Quantitative high-throughput screening (qHTS) assays are increasingly being employed to inform chemical hazard identification. Hundreds of chemicals have been tested in dozens of cell lines across extensive concentration ranges by the National Toxicology Program in collaboration with the NIH Chemical Genomics Center. Objectives: To test a hypothesis that dose-response data points of the qHTS assays can serve as biological descriptors of assayed chemicals and, when combined with conventional chemical descriptors, may improve the accuracy of Quantitative Structure-Activity Relationship (QSAR) models applied to prediction of in vivo toxicity endpoints. Methods and Results: The cell viability qHTS concentration-response data for 1,408 substances assayed in 13 cell lines were obtained from PubChem; for a subset of these compounds rodent acute toxicity LD50 data were also available. The classification k Nearest Neighbor and Random Forest QSAR methods were employed for modeling LD50 data using either chemical descriptors alone (conventional models) or in combination with biological descriptors derived from the concentration-response qHTS data (hybrid models). Critical to our approach was the use of a novel noise-filtering algorithm to treat qHTS data. We show that both the external classification accuracy and coverage (i.e., fraction of compounds in the external set that fall within the applicability domain) of the hybrid QSAR models was superior to convent

  13. Quantitative Real-Time PCR using the Thermo Scientific Solaris qPCR Assay

    PubMed Central

    Ogrean, Christy; Jackson, Ben; Covino, James

    2010-01-01

    The Solaris qPCR Gene Expression Assay is a novel type of primer/probe set, designed to simplify the qPCR process while maintaining the sensitivity and accuracy of the assay. These primer/probe sets are pre-designed to >98% of the human and mouse genomes and feature significant improvements from previously available technologies. These improvements were made possible by virtue of a novel design algorithm, developed by Thermo Scientific bioinformatics experts. Several convenient features have been incorporated into the Solaris qPCR Assay to streamline the process of performing quantitative real-time PCR. First, the protocol is similar to commonly employed alternatives, so the methods used during qPCR are likely to be familiar. Second, the master mix is blue, which makes setting the qPCR reactions easier to track. Third, the thermal cycling conditions are the same for all assays (genes), making it possible to run many samples at a time and reducing the potential for error. Finally, the probe and primer sequence information are provided, simplifying the publication process. Here, we demonstrate how to obtain the appropriate Solaris reagents using the GENEius product search feature found on the ordering web site (www.thermo.com/solaris) and how to use the Solaris reagents for performing qPCR using the standard curve method. PMID:20567213

  14. Determination of dabigatran, rivaroxaban and apixaban by ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) and coagulation assays for therapy monitoring of novel direct oral anticoagulants.

    PubMed

    Schmitz, E M H; Boonen, K; van den Heuvel, D J A; van Dongen, J L J; Schellings, M W M; Emmen, J M A; van der Graaf, F; Brunsveld, L; van de Kerkhof, D

    2014-10-01

    Three novel direct oral anticoagulants (DOACs) have recently been registered by the Food and Drug Administration and European Medicines Agency Commission: dabigatran, rivaroxaban, and apixaban. To quantify DOACs in plasma, various dedicated coagulation assays have been developed. To develop and validate a reference ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) method and to evaluate the analytical performance of several coagulation assays for quantification of dabigatran, rivaroxaban, and apixaban. The developed UPLC-MS/MS method was validated by determination of precision, accuracy, specificity, matrix effects, lower limits of detection, carry-over, recovery, stability, and robustness. The following coagulation assays were evaluated for accuracy and precision: laboratory-developed (LD) diluted thrombin time (dTT), Hemoclot dTT, Pefakit PiCT, ECA, Liquid anti-Xa, Biophen Heparin (LRT), and Biophen DiXal anti-Xa. Agreement between the various coagulation assays and UPLC-MS/MS was determined with random samples from patients using dabigatran or rivaroxaban. The UPLC-MS/MS method was shown to be accurate, precise, sensitive, stable, and robust. The dabigatran coagulation assay showing the best precision, accuracy and agreement with the UPLC-MS/MS method was the LD dTT test. For rivaroxaban, the anti-factor Xa assays were superior to the PiCT-Xa assay with regard to precision, accuracy, and agreement with the reference method. For apixaban, the Liquid anti-Xa assay was superior to the PiCT-Xa assay. Statistically significant differences were observed between the various coagulation assays as compared with the UPLC-MS/MS reference method. It is currently unknown whether these differences are clinically relevant. When DOACs are quantified with coagulation assays, comparison with a reference method as part of proficiency testing is therefore pivotal. © 2014 International Society on Thrombosis and Haemostasis.

  15. Performance Assessment of a Trypanosoma cruzi Chimeric Antigen in Multiplex Liquid Microarray Assays.

    PubMed

    Santos, Fred Luciano Neves; Celedon, Paola Alejandra Fiorani; Zanchin, Nilson Ivo Tonin; Leitolis, Amanda; Crestani, Sandra; Foti, Leonardo; de Souza, Wayner Vieira; Gomes, Yara de Miranda; Krieger, Marco Aurélio

    2017-10-01

    Diagnosing chronic Chagas disease (CD) requires antibody-antigen detection methods, which are traditionally based on enzymatic assay techniques whose performance depend on the type and quality of antigen used. Previously, 4 recombinant chimeric proteins from the Instituto de Biologia Molecular do Paraná (IBMP-8.1 to 8.4) comprising immuno-dominant regions of diverse Trypanosoma cruzi antigens showed excellent diagnostic performance in enzyme-linked immunosorbent assays. Considering that next-generation platforms offer improved CD diagnostic accuracy with different T. cruzi -specific recombinant antigens, we assessed the performance of these chimeras in liquid microarrays (LMAs). The chimeric proteins were expressed in Escherichia coli and purified by chromatography. Sera from 653 chagasic and 680 healthy individuals were used to assess the performance of these chimeras in detecting specific anti- T. cruzi antibodies. Accuracies ranged from 98.1 to 99.3%, and diagnostic odds ratio values were 3,548 for IBMP-8.3, 4,826 for IBMP-8.1, 7,882 for IBMP-8.2, and 25,000 for IBMP-8.4. A separate sera bank (851 samples) was employed to assess cross-reactivity with other tropical diseases. Leishmania , a pathogen with high similarity to T. cruzi , showed cross-reactivity rates ranging from 0 to 2.17%. Inconclusive results were negligible (0 to 0.71%). Bland-Altman and Deming regression analysis based on 200 randomly selected CD-positive and negative samples demonstrated interchangeability with respect to CD diagnostic performance in both singleplex and multiplex assays. Our results suggested that these chimeras can potentially replace antigens currently used in commercially available assay kits. Moreover, the use of multiplex platforms, such as LMA assays employing 2 or more IBMP antigens, would abrogate the need for 2 different testing techniques when diagnosing CD. Copyright © 2017 American Society for Microbiology.

  16. Enhancement of Human Antigen-Specific Memory T-Cell Responses by Interleukin-7 May Improve Accuracy in Diagnosing Tuberculosis▿ †

    PubMed Central

    Feske, Marsha; Nudelman, Rodolfo J.; Medina, Miguel; Lew, Justin; Singh, Manisha; Couturier, Jacob; Graviss, Edward A.; Lewis, Dorothy E.

    2008-01-01

    Children and immunocompromised adults are at an increased risk of tuberculosis (TB), but diagnosis is more challenging. Recently developed gamma interferon (IFN-γ) release assays provide increased sensitivity and specificity for diagnosis of latent TB, but their use is not FDA approved in immunocompromised or pediatric populations. Both populations have reduced numbers of T cells, which are major producers of IFN-γ. Interleukin 7 (IL-7), a survival cytokine, stabilizes IFN-γ message and increases protein production. IL-7 was added to antigen-stimulated lymphocytes to improve IFN-γ responses as measured by enzyme-linked immunosorbent assay (ELISA) and enzyme-linked immunospot (ELISPOT) assay. Antigens used were tetanus toxoid (n = 10), p24 (from human immunodeficiency virus [HIV], n = 9), and TB peptides (n = 15). Keyhole limpet hemocyanin was used as a negative control, and phytohemagglutinin was the positive control. IL-7 improved antigen-specific responses to all antigens tested including tetanus toxoid, HIV type 1 p24, and TB peptides (ESAT-6 and CFP-10) with up to a 14-fold increase (mean = 3.8), as measured by ELISA. Increased IFN-γ responses from controls, HIV-positive patients, and TB patients were statistically significant, with P values of <0.05, 0.01, and 0.05, respectively. ELISPOT assay results confirmed ELISA findings (P values of <0.01, 0.02, and 0.03, respectively), with a strong correlation between the two tests (R2 = 0.82 to 0.99). Based on average background levels, IL-7 increased detection of IFN-γ by 39% compared to the level with antigen alone. Increased production of IFN-γ induced by IL-7 improves sensitivity of ELISA and ELISPOT assays for all antigens tested. Further enhancement of IFN-γ-based assays might improve TB diagnosis in those populations at highest risk for TB. PMID:18753334

  17. Automation of the anthrone assay for carbohydrate concentration determinations.

    PubMed

    Turula, Vincent E; Gore, Thomas; Singh, Suddham; Arumugham, Rasappa G

    2010-03-01

    Reported is the adaptation of a manual polysaccharide assay applicable for glycoconjugate vaccines such as Prevenar to an automated liquid handling system (LHS) for improved performance. The anthrone assay is used for carbohydrate concentration determinations and was scaled to the microtiter plate format with appropriate mixing, dispensing, and measuring operations. Adaptation and development of the LHS platform was performed with both dextran polysaccharides of various sizes and pneumococcal serotype 6A polysaccharide (PnPs 6A). A standard plate configuration was programmed such that the LHS diluted both calibration standards and a test sample multiple times with six replicate preparations per dilution. This extent of replication minimized the effect of any single deviation or delivery error that might have occurred. Analysis of the dextran polymers ranging in size from 214 kDa to 3.755 MDa showed that regardless of polymer chain length the hydrolysis was complete, as evident by uniform concentration measurements. No plate positional absorbance bias was observed; of 12 plates analyzed to examine positional bias the largest deviation observed was 0.02% percent relative standard deviation (%RSD). The high purity dextran also afforded the opportunity to assess LHS accuracy; nine replicate analyses of dextran yielded a mean accuracy of 101% recovery. As for precision, a total of 22 unique analyses were performed on a single lot of PnPs 6A, and the resulting variability was 2.5% RSD. This work demonstrated the capability of a LHS to perform the anthrone assay consistently and a reduced assay cycle time for greater laboratory capacity.

  18. Factors Affecting Accuracy and Time Requirements of a Glucose Oxidase-Peroxidase Assay for Determination of Glucose

    USDA-ARS?s Scientific Manuscript database

    Accurate and rapid assays for glucose are desirable for analysis of glucose and starch in food and feedstuffs. An established colorimetric glucose oxidase-peroxidase method for glucose was modified to reduce analysis time, and evaluated for factors that affected accuracy. Time required to perform t...

  19. Accurate Region-of-Interest Recovery Improves the Measurement of the Cell Migration Rate in the In Vitro Wound Healing Assay.

    PubMed

    Bedoya, Cesar; Cardona, Andrés; Galeano, July; Cortés-Mancera, Fabián; Sandoz, Patrick; Zarzycki, Artur

    2017-12-01

    The wound healing assay is widely used for the quantitative analysis of highly regulated cellular events. In this essay, a wound is voluntarily produced on a confluent cell monolayer, and then the rate of wound reduction (WR) is characterized by processing images of the same regions of interest (ROIs) recorded at different time intervals. In this method, sharp-image ROI recovery is indispensable to compensate for displacements of the cell cultures due either to the exploration of multiple sites of the same culture or to transfers from the microscope stage to a cell incubator. ROI recovery is usually done manually and, despite a low-magnification microscope objective is generally used (10x), repositioning imperfections constitute a major source of errors detrimental to the WR measurement accuracy. We address this ROI recovery issue by using pseudoperiodic patterns fixed onto the cell culture dishes, allowing the easy localization of ROIs and the accurate quantification of positioning errors. The method is applied to a tumor-derived cell line, and the WR rates are measured by means of two different image processing software. Sharp ROI recovery based on the proposed method is found to improve significantly the accuracy of the WR measurement and the positioning under the microscope.

  20. A sensitive branched DNA HIV-1 signal amplification viral load assay with single day turnaround.

    PubMed

    Baumeister, Mark A; Zhang, Nan; Beas, Hilda; Brooks, Jesse R; Canchola, Jesse A; Cosenza, Carlo; Kleshik, Felix; Rampersad, Vinod; Surtihadi, Johan; Battersby, Thomas R

    2012-01-01

    Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) ("Versant Assay") currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16-18 h to 2.5 h, composition of only the "Lysis Diluent" solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements.

  1. Rapid immunoassays for diagnosis of heparin-induced thrombocytopenia: Comparison of diagnostic accuracy, reproducibility, and costs in clinical practice

    PubMed Central

    Bankova, Andriyana; Andres, Yvonne; Horn, Michael P.; Alberio, Lorenzo

    2017-01-01

    Background Immunoassays are crucial in the work-up of patients with suspected heparin-induced thrombocytopenia (HIT) and rapid tests have been recently developed. However, comparative data on diagnostic accuracy, reproducibility, and analytical costs of different immunoassays in clinical practice are limited. Methods Samples of 179 consecutive patients evaluated for suspected HIT in clinical practice using a polyspecific enzyme-linked immunoabsorbent assay (GTI diagnostics; ELISA) and a rapid particle gel immunoassay (PaGIA), were additionally analysed with a IgG-specific chemiluminescent immunoassay (AcuStar HIT-IgG). Presence of HIT was defined as a positive functional heparin-induced platelet aggregation test. Diagnostic accuracy was determined for low, intermediate and high thresholds as previously established (ELISA: optical density 0.4, 1.3, and 2.0 respectively; PaGIA: positive/negative, titre of 4, titre of 32; AcuStar HIT-IgG: 1.0 U/ml, 2.8, 9.4) and reproducibility was assessed by repeated measurements. Costs of test determination were calculated taking reagents, controls, and working time of technicians according to Swiss health care system into account. Results Data on PaGIA results were available for 171 patients (95.5%), ELISA for 144 patients (80.4%), and AcuStar HIT-IgG for 179 patients (100%). Sensitivity was above 95% for all assays at low and intermediate thresholds. Specificity increased with higher thresholds and was above 90% for all assays with intermediate and high thresholds. Specificity of AcuStar HIT-IgG (92.8%; 95% CI 87.7, 96.2) was significantly higher than PaGIA (83.0%; 95% CI 76.3, 88.5) and higher than ELISA (81.8%, 95% CI 74.2, 88.0) at low threshold (p<0.05). Reproducibility was adequate for all assays. Total costs per test were CHF 51.02 for ELISA, 117.70 for AcuStar HIT-IgG, and 83.13 for PaGIA. Conclusions We observed favourable diagnostic accuracy measures and a high reproducibility for PaGIA and AcuStar HIT-IgG. Implementation into 24-hours-service might improve patient care but the results must be confirmed in other settings and larger populations as well. PMID:28594835

  2. Effect of N-acetylcysteine on the accuracy of the prothrombin time assay of plasma coagulation factor II+VII+X activity in subjects infused with the drug. Influence of time and temperature.

    PubMed

    Thorsen, Sixtus; Teisner, Ane; Jensen, Søren Astrup; Philips, Malou; Dalhoff, Kim; Bendtsen, Flemming

    2009-01-01

    The prothrombin time (PT) assay of factor II+VII+X activity is an important predictor of liver damage in paracetamol poisoned patients. It complicates interpretation of results that the antidote, acetylcysteine (NAC) depresses this activity. The aim was to investigate if NAC influences the accuracy of the plasma PT assay. The accuracy of Nycotest PT was studied using plasma added NAC in vitro and plasma from subjects infused with NAC. The latter results were compared with those obtained by analysis of PT by CoaguChek S. Therapeutic NAC concentrations added to plasma in vitro decreased factor II+VII+X activity at 37 degrees C in a time-dependent manner. This effect was quenched at temperatures <24 degrees C. Activity lost at 37 degrees C could partly be recovered by subsequent incubation at 5 or 20 degrees C. Incubation at 37 degrees C prior to assay led to a significant additional depression of factor II+VII+X activity in plasma from subjects infused with NAC during the first 3h of infusion indicating that it contained reactive NAC. The risk that this NAC interfered with the accuracy of the PT assay was considered minimal with samples stored below 24 degrees C. This was supported by similarity of results obtained by analysis of appropriately stored plasma and simultaneously drawn blood by CoaguChek S. Residual reactive NAC does not interfere with the accuracy of the PT assay of plasma stored below 24 degrees C, but NAC-induced loss in activity at 37 degrees C may be partly recovered during subsequent storage below 24 degrees C.

  3. Lowering the quantification limit of the QubitTM RNA HS assay using RNA spike-in.

    PubMed

    Li, Xin; Ben-Dov, Iddo Z; Mauro, Maurizio; Williams, Zev

    2015-05-06

    RNA quantification is often a prerequisite for most RNA analyses such as RNA sequencing. However, the relatively low sensitivity and large sample consumption of traditional RNA quantification methods such as UV spectrophotometry and even the much more sensitive fluorescence-based RNA quantification assays, such as the Qubit™ RNA HS Assay, are often inadequate for measuring minute levels of RNA isolated from limited cell and tissue samples and biofluids. Thus, there is a pressing need for a more sensitive method to reliably and robustly detect trace levels of RNA without interference from DNA. To improve the quantification limit of the Qubit™ RNA HS Assay, we spiked-in a known quantity of RNA to achieve the minimum reading required by the assay. Samples containing trace amounts of RNA were then added to the spike-in and measured as a reading increase over RNA spike-in baseline. We determined the accuracy and precision of reading increases between 1 and 20 pg/μL as well as RNA-specificity in this range, and compared to those of RiboGreen(®), another sensitive fluorescence-based RNA quantification assay. We then applied Qubit™ Assay with RNA spike-in to quantify plasma RNA samples. RNA spike-in improved the quantification limit of the Qubit™ RNA HS Assay 5-fold, from 25 pg/μL down to 5 pg/μL while maintaining high specificity to RNA. This enabled quantification of RNA with original concentration as low as 55.6 pg/μL compared to 250 pg/μL for the standard assay and decreased sample consumption from 5 to 1 ng. Plasma RNA samples that were not measurable by the Qubit™ RNA HS Assay were measurable by our modified method. The Qubit™ RNA HS Assay with RNA spike-in is able to quantify RNA with high specificity at 5-fold lower concentration and uses 5-fold less sample quantity than the standard Qubit™ Assay.

  4. Melt Analysis of Mismatch Amplification Mutation Assays (Melt-MAMA): A Functional Study of a Cost-Effective SNP Genotyping Assay in Bacterial Models

    PubMed Central

    Birdsell, Dawn N.; Pearson, Talima; Price, Erin P.; Hornstra, Heidie M.; Nera, Roxanne D.; Stone, Nathan; Gruendike, Jeffrey; Kaufman, Emily L.; Pettus, Amanda H.; Hurbon, Audriana N.; Buchhagen, Jordan L.; Harms, N. Jane; Chanturia, Gvantsa; Gyuranecz, Miklos; Wagner, David M.; Keim, Paul S.

    2012-01-01

    Single nucleotide polymorphisms (SNPs) are abundant in genomes of all species and biologically informative markers extensively used across broad scientific disciplines. Newly identified SNP markers are publicly available at an ever-increasing rate due to advancements in sequencing technologies. Efficient, cost-effective SNP genotyping methods to screen sample populations are in great demand in well-equipped laboratories, but also in developing world situations. Dual Probe TaqMan assays are robust but can be cost-prohibitive and require specialized equipment. The Mismatch Amplification Mutation Assay, coupled with melt analysis (Melt-MAMA), is flexible, efficient and cost-effective. However, Melt-MAMA traditionally suffers from high rates of assay design failures and knowledge gaps on assay robustness and sensitivity. In this study, we identified strategies that improved the success of Melt-MAMA. We examined the performance of 185 Melt-MAMAs across eight different pathogens using various optimization parameters. We evaluated the effects of genome size and %GC content on assay development. When used collectively, specific strategies markedly improved the rate of successful assays at the first design attempt from ∼50% to ∼80%. We observed that Melt-MAMA accurately genotypes across a broad DNA range (∼100 ng to ∼0.1 pg). Genomic size and %GC content influence the rate of successful assay design in an independent manner. Finally, we demonstrated the versatility of these assays by the creation of a duplex Melt-MAMA real-time PCR (two SNPs) and conversion to a size-based genotyping system, which uses agarose gel electrophoresis. Melt-MAMA is comparable to Dual Probe TaqMan assays in terms of design success rate and accuracy. Although sensitivity is less robust than Dual Probe TaqMan assays, Melt-MAMA is superior in terms of cost-effectiveness, speed of development and versatility. We detail the parameters most important for the successful application of Melt-MAMA, which should prove useful to the wider scientific community. PMID:22438886

  5. A Sensitive Branched DNA HIV-1 Signal Amplification Viral Load Assay with Single Day Turnaround

    PubMed Central

    Baumeister, Mark A.; Zhang, Nan; Beas, Hilda; Brooks, Jesse R.; Canchola, Jesse A.; Cosenza, Carlo; Kleshik, Felix; Rampersad, Vinod; Surtihadi, Johan; Battersby, Thomas R.

    2012-01-01

    Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) (“Versant Assay”) currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16–18 h to 2.5 h, composition of only the “Lysis Diluent” solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements. PMID:22479381

  6. A Systematic Investigation of Parameters Influencing Droplet Rain in the Listeria monocytogenes prfA Assay - Reduction of Ambiguous Results in ddPCR

    PubMed Central

    Witte, Anna Kristina; Mester, Patrick; Fister, Susanne; Witte, Matthias; Schoder, Dagmar; Rossmanith, Peter

    2016-01-01

    The droplet digital polymerase chain reaction (ddPCR) determines DNA amounts based upon the pattern of positive and negative droplets, according to Poisson distribution, without the use of external standards. However, division into positive and negative droplets is often not clear because a part of the droplets has intermediate fluorescence values, appearing as “rain” in the plot. Despite the droplet rain, absolute quantification with ddPCR is possible, as shown previously for the prfA assay in quantifying Listeria monocytogenes. Nevertheless, reducing the rain, and thus ambiguous results, promotes the accuracy and credibility of ddPCR. In this study, we extensively investigated chemical and physical parameters for optimizing the prfA assay for ddPCR. While differences in the concentration of all chemicals and the dye, quencher and supplier of the probe did not alter the droplet pattern, changes in the PCR cycling program, such as prolonged times and increased cycle numbers, improved the assay. PMID:27992475

  7. A Systematic Investigation of Parameters Influencing Droplet Rain in the Listeria monocytogenes prfA Assay - Reduction of Ambiguous Results in ddPCR.

    PubMed

    Witte, Anna Kristina; Mester, Patrick; Fister, Susanne; Witte, Matthias; Schoder, Dagmar; Rossmanith, Peter

    2016-01-01

    The droplet digital polymerase chain reaction (ddPCR) determines DNA amounts based upon the pattern of positive and negative droplets, according to Poisson distribution, without the use of external standards. However, division into positive and negative droplets is often not clear because a part of the droplets has intermediate fluorescence values, appearing as "rain" in the plot. Despite the droplet rain, absolute quantification with ddPCR is possible, as shown previously for the prfA assay in quantifying Listeria monocytogenes. Nevertheless, reducing the rain, and thus ambiguous results, promotes the accuracy and credibility of ddPCR. In this study, we extensively investigated chemical and physical parameters for optimizing the prfA assay for ddPCR. While differences in the concentration of all chemicals and the dye, quencher and supplier of the probe did not alter the droplet pattern, changes in the PCR cycling program, such as prolonged times and increased cycle numbers, improved the assay.

  8. International Validation of Two Human Recombinant Estrogen ...

    EPA Pesticide Factsheets

    An international validation study has been successfully completed for 2 competitive binding assays using human recombinant ERa. Assays evaluated included the Freyberger-Wilson (FW) assay using a full length human ER, and the Chemical Evaluation and Research Institute (CERI) assay using a ligand-binding domain of the human ER. Twenty three compounds were tested in 6 laboratories for the FW assay and 5 for the CERJ assay, which included three controls (used with every run), 9 uncoded, and 14 coded chemicals across 3 subtasks. The overall goal of this validation study was to demonstrate the ability of each of the two assays to reliably classify the test chemicals as binders or non-binders. Laboratories had little trouble with the ER binders that produced a full binding curve when using either the CERI or FW assays. As is typical with all ER competitive binding assays, the weak binders proved to be more challenging. However, overall results from both the FW and CERI assays were consistent and in agreement with expected classifications regardless of the form of the hrER (i.e., full length ER versus an ER ligand binding domain) or the subtle differences in the protocols for conducting each assay. The reproducibility and accuracy for classification of chemicals as potential ER binders and non- binders using the FW and CERI hrER binding assays were comparable to that of the U.S.EPA’s existing ER binding test guideline OPPTS 890.1250, while providing an improved, highe

  9. Determination of L1 retrotransposition kinetics in cultured cells

    PubMed Central

    Ostertag, Eric M.; Luning Prak, Eline T.; DeBerardinis, Ralph J.; Moran, John V.; Kazazian, Haig H.

    2000-01-01

    L1 retrotransposons are autonomous retroelements that are active in the human and mouse genomes. Previously, we developed a cultured cell assay that uses a neomycin phosphotransferase (neo) retrotransposition cassette to determine relative retrotransposition frequencies among various L1 elements. Here, we describe a new retrotransposition assay that uses an enhanced green fluorescent protein (EGFP) retrotransposition cassette to determine retrotransposition kinetics in cultured cells. We show that retrotransposition is not detected in cultured cells during the first 48 h post-transfection, but then proceeds at a continuous high rate for at least 16 days. We also determine the relative retrotransposition rates of two similar human L1 retrotransposons, L1RP and L1.3. L1RP retrotransposed in the EGFP assay at a rate of ~0.5% of transfected cells/day, ~3-fold higher than the rate measured for L1.3. We conclude that the new assay detects near real time retrotransposition in a single cell and is sufficiently sensitive to differentiate retrotransposition rates among similar L1 elements. The EGFP assay exhibits improved speed and accuracy compared to the previous assay when used to determine relative retrotransposition frequencies. Furthermore, the EGFP cassette has an expanded range of experimental applications. PMID:10684937

  10. Evaluation of the diagnostic value of serologic microagglutination testing and a polymerase chain reaction assay for diagnosis of acute leptospirosis in dogs in a referral center.

    PubMed

    Fraune, Claudia Kümmerle; Schweighauser, Ariane; Francey, Thierry

    2013-05-15

    To determine the diagnostic value of a serologic microagglutination test (MAT) and a PCR assay on urine and blood for the diagnosis of leptospirosis in dogs with acute kidney injury (AKI). Cross-sectional study. Animals-76 dogs with AKI in a referral hospital (2008 to 2009). Dogs' leptospirosis status was defined with a paired serologic MAT against a panel of 11 Leptospira serovars as leptospirosis-associated (n = 30) or nonleptospirosis-associated AKI (12). In 34 dogs, convalescent serologic testing was not possible, and leptospirosis status was classified as undetermined. The diagnostic value of the MAT single acute or convalescent blood sample was determined in dogs in which leptospirosis status could be classified. The diagnostic value of a commercially available genus-specific PCR assay was evaluated by use of 36 blood samples and 20 urine samples. Serologic acute testing of an acute blood sample had a specificity of 100% (95% CI, 76% to 100%), a sensitivity of 50% (33% to 67%), and an accuracy of 64% (49% to 77%). Serologic testing of a convalescent blood sample had a specificity of 92% (65% to 99%), a sensitivity of 100% (87% to 100%), and an accuracy of 98% (88% to 100%). Results of the Leptospira PCR assay were negative for all samples from dogs for which leptospirosis status could be classified. Serologic MAT results were highly accurate for diagnosis of leptospirosis in dogs, despite a low sensitivity for early diagnosis. In this referral setting of dogs pretreated with antimicrobials, testing of blood and urine samples with a commercially available genus-specific PCR assay did not improve early diagnosis.

  11. A comparison of the sensitivity, specificity, and molecular weight accuracy of three different commercially available Hyaluronan ELISA-like assays.

    PubMed

    Haserodt, Sarah; Aytekin, Metin; Dweik, Raed A

    2011-02-01

    Hyaluronan (HA) is a glycosaminoglycan found in the extracellular matrix and ranges from several thousand to millions of daltons in size. HA has importance in various pathological conditions and is known to be elevated in several diseases. Three commonly used, commercially available HA enzyme-linked immunosorbent assay (ELISA)-like assays (from Corgenix, Echelon and R&D) were compared on the basis of accuracy, sample variability and ability to measure a range of HA sizes. The Corgenix HA ELISA-like assay displayed the lowest intra-assay variability [coefficient of variation (CV) = 11.7 ± 3.6%], followed by R&D (CV = 12.3 ± 4.6%) and Echelon (CV = 18.9 ± 9.2%). Interassay variability was also lowest for the Corgenix assay (CV = 6.0%), intermediate for the Echelon assay (9.5%) and highest for the R&D assay (CV = 34.1%). The high interassay variability seen for the R&D assay may have been due to the effect of dilution, since the dilution-independent interassay variability was 15.5%. The concentration of the standard HA was overestimated by the Echelon assay by 85% and underestimated by the R&D and Corgenix assays by 34 and 32%, respectively. The Echelon HA ELISA-like assay was the most effective at measuring all sizes of HA tested (2 MDa and 132, 66 and 6.4 kDa), whereas the Corgenix and R&D assays were unable to detect 6.4 kDa HA. These findings suggest that the Echelon HA ELISA-like assay is better suited for size-sensitive HA measurements but has a relatively high variability. The Corgenix and R&D HA ELISA-like assays have low variability and high accuracy but are not suitable for detecting low-molecular-weight HA.

  12. A Highly Predictive Model for Diagnosis of Colorectal Neoplasms Using Plasma MicroRNA: Improving Specificity and Sensitivity

    PubMed Central

    Carter, Jane V.; Roberts, Henry L.; Pan, Jianmin; Rice, Jonathan D.; Burton, James F.; Galbraith, Norman J.; Eichenberger, M. Robert; Jorden, Jeffery; Deveaux, Peter; Farmer, Russell; Williford, Anna; Kanaan, Ziad; Rai, Shesh N.; Galandiuk, Susan

    2016-01-01

    OBJECTIVE(S) Develop a plasma-based microRNA (miRNA) diagnostic assay specific for colorectal neoplasms, building upon our prior work. BACKGROUND Colorectal neoplasms (colorectal cancer [CRC] and colorectal advanced adenoma [CAA]) frequently develop in individuals at ages when other common cancers also occur. Current screening methods lack sensitivity, specificity, and have poor patient compliance. METHODS Plasma was screened for 380 miRNAs using microfluidic array technology from a “Training” cohort of 60 patients, (10 each) control, CRC, CAA, breast (BC), pancreatic (PC) and lung (LC) cancer. We identified uniquely dysregulated miRNAs specific for colorectal neoplasia (p<0.05, false discovery rate: 5%, adjusted α=0.0038). These miRNAs were evaluated using single assays in a “Test” cohort of 120 patients. A mathematical model was developed to predict blinded sample identity in a 150 patient “Validation” cohort using repeat-sub-sampling validation of the testing dataset with 1000 iterations each to assess model detection accuracy. RESULTS Seven miRNAs (miR-21, miR-29c, miR-122, miR-192, miR-346, miR-372, miR-374a) were selected based upon p-value, area-under-the-curve (AUC), fold-change, and biological plausibility. AUC (±95% CI) for “Test” cohort comparisons were 0.91 (0.85-0.96), 0.79 (0.70-0.88) and 0.98 (0.96-1.0), respectively. Our mathematical model predicted blinded sample identity with 69-77% accuracy between all neoplasia and controls, 67-76% accuracy between colorectal neoplasia and other cancers, and 86-90% accuracy between colorectal cancer and colorectal adenoma. CONCLUSIONS Our plasma miRNA assay and prediction model differentiates colorectal neoplasia from patients with other neoplasms and from controls with higher sensitivity and specificity compared to current clinical standards. PMID:27471839

  13. Historical milestones in measurement of HDL-cholesterol: impact on clinical and laboratory practice.

    PubMed

    Langlois, Michel R; Blaton, Victor H

    2006-07-23

    High-density lipoprotein cholesterol (HDL-C) comprises a family of particles with differing physicochemical characteristics. Continuing progress in improving HDL-C analysis has originated from two separate fields-one clinical, reflecting increased attention to HDL-C in estimating risk for coronary heart disease (CHD), and the other analytical, reflecting increased emphasis on finding more reliable and cost-effective HDL-C assays. Epidemiologic and prospective studies established the inverse association of HDL-C with CHD risk, a relationship that is consistent with protective mechanisms demonstrated in basic research and animal studies. Atheroprotective and less atheroprotective HDL subpopulations have been described. Guidelines on primary and secondary CHD prevention, which increased the workload in clinical laboratories, have led to a revolution in HDL-C assay technology. Many analytical techniques including ultracentrifugation, electrophoresis, chromatography, and polyanion precipitation methods have been developed to separate and quantify HDL-C and HDL subclasses. More recently developed homogeneous assays enable direct measurement of HDL-C on an automated analyzer, without the need for manual pretreatment to separate non-HDL. Although homogeneous assays show improved accuracy and precision in normal serum, discrepant results exist in samples with atypical lipoprotein characteristics. Hypertriglyceridemia and monoclonal paraproteins are important interfering factors. A novel approach is nuclear magnetic resonance spectroscopy that allows rapid and reliable analysis of lipoprotein subclasses, which may improve the identification of individuals at increased CHD risk. Apolipoprotein A-I, the major protein of HDL, has been proposed as an alternative cardioprotective marker avoiding the analytical limitations of HDL-C.

  14. Digital detection of endonuclease mediated gene disruption in the HIV provirus

    PubMed Central

    Sedlak, Ruth Hall; Liang, Shu; Niyonzima, Nixon; De Silva Feelixge, Harshana S.; Roychoudhury, Pavitra; Greninger, Alexander L.; Weber, Nicholas D.; Boissel, Sandrine; Scharenberg, Andrew M.; Cheng, Anqi; Magaret, Amalia; Bumgarner, Roger; Stone, Daniel; Jerome, Keith R.

    2016-01-01

    Genome editing by designer nucleases is a rapidly evolving technology utilized in a highly diverse set of research fields. Among all fields, the T7 endonuclease mismatch cleavage assay, or Surveyor assay, is the most commonly used tool to assess genomic editing by designer nucleases. This assay, while relatively easy to perform, provides only a semi-quantitative measure of mutation efficiency that lacks sensitivity and accuracy. We demonstrate a simple droplet digital PCR assay that quickly quantitates a range of indel mutations with detection as low as 0.02% mutant in a wild type background and precision (≤6%CV) and accuracy superior to either mismatch cleavage assay or clonal sequencing when compared to next-generation sequencing. The precision and simplicity of this assay will facilitate comparison of gene editing approaches and their optimization, accelerating progress in this rapidly-moving field. PMID:26829887

  15. Development and inter-laboratory validation study of an improved new real-time PCR assay with internal control for detection and laboratory diagnosis of African swine fever virus.

    PubMed

    Tignon, Marylène; Gallardo, Carmina; Iscaro, Carmen; Hutet, Evelyne; Van der Stede, Yves; Kolbasov, Denis; De Mia, Gian Mario; Le Potier, Marie-Frédérique; Bishop, Richard P; Arias, Marisa; Koenen, Frank

    2011-12-01

    A real-time polymerase chain reaction (PCR) assay for the rapid detection of African swine fever virus (ASFV), multiplexed for simultaneous detection of swine beta-actin as an endogenous control, has been developed and validated by four National Reference Laboratories of the European Union for African swine fever (ASF) including the European Union Reference Laboratory. Primers and a TaqMan(®) probe specific for ASFV were selected from conserved regions of the p72 gene. The limit of detection of the new real-time PCR assay is 5.7-57 copies of the ASFV genome. High accuracy, reproducibility and robustness of the PCR assay (CV ranging from 0.7 to 5.4%) were demonstrated both within and between laboratories using different real-time PCR equipments. The specificity of virus detection was validated using a panel of 44 isolates collected over many years in various geographical locations in Europe, Africa and America, including recent isolates from the Caucasus region, Sardinia, East and West Africa. Compared to the OIE-prescribed conventional and real-time PCR assays, the sensitivity of the new assay with internal control was improved, as demonstrated by testing 281 field samples collected in recent outbreaks and surveillance areas in Europe and Africa (170 samples) together with samples obtained through experimental infections (111 samples). This is particularly evident in the early days following experimental infection and during the course of the disease in pigs sub-clinically infected with strains of low virulence (from 35 up to 70dpi). The specificity of the assay was also confirmed on 150 samples from uninfected pigs and wild boar from ASF-free areas. Measured on the total of 431 tested samples, the positive deviation of the new assay reaches 21% or 26% compared to PCR and real-time PCR methods recommended by OIE. This improved and rigorously validated real-time PCR assay with internal control will provide a rapid, sensitive and reliable molecular tool for ASFV detection in pigs in newly infected areas, control in endemic areas and surveillance in ASF-free areas. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. A TSHR-LH/CGR chimera that measures functional thyroid-stimulating autoantibodies (TSAb) can predict remission or recurrence in Graves' patients undergoing antithyroid drug (ATD) treatment.

    PubMed

    Giuliani, Cesidio; Cerrone, Dominique; Harii, Norikazu; Thornton, Mark; Kohn, Leonard D; Dagia, Nilesh M; Bucci, Ines; Carpentieri, Maria; Di Nenno, Barbara; Di Blasio, Andrea; Vitti, Paolo; Monaco, Fabrizio; Napolitano, Giorgio

    2012-07-01

    A functional thyroid-stimulating autoantibodies (TSAb) assay using a thyroid-stimulating hormone receptor chimera (Mc4) appears to be clinically more useful than the commonly used assay, a binding assay that measures all the antibodies binding to the thyroid-stimulating hormone receptor without functional discrimination, in diagnosing patient with Graves' disease (GD). The objective of the study was to investigate whether an Mc4 assay can predict relapse/remission of hyperthyroidism after antithyroid drug (ATD) treatment in patients with GD. An Mc4 assay was used to prospectively track TSAb activity in GD patients treated with ATD over a 5-yr period. GD patients from the Chieti University participated in this study. Interventions included the assessment of patients' sera using the Mc4 assay, the Mc4-derivative assay (Thyretain), and a human monoclonal thyroid-stimulating hormone receptor antibody, M22 assay. The Mc4 assay, a sensitive index of remission and recurrence, was used in this study. The TSAb levels significantly decreased only in the remitting group as evidenced by Mc4 assay values at the end of ATD (0.96 ± 1.47, 10.9 ± 26.6. and 24.7 ± 37.5 arbitrary units for the remitting, relapsing, and unsuspended therapy groups, respectively). Additional prognostic help was obtained by thyroid volume measurements at the end of treatment. Although not statistically significant, the Mc4 assay has a trend toward improved positive predictive value (95.4 vs. 84.2 or 87.5%), specificity (96.4 vs. 86.4 and 90.9%), and accuracy (87.3 vs. 83.3 and 80.9%) comparing the Mc4, Thyretain, and M22 assays, respectively. Thyretain has a trend toward improved negative predictive value (82.6 vs. 81.8 and 76.9%) and sensitivity (80 vs. 77.8 and 70%) comparing Thyretain, Mc4, and M22 assays, respectively. The Mc4 assay is a clinically useful index of remission and relapse in patients with GD. Larger studies are required to confirm these findings.

  17. HT-COMET: a novel automated approach for high throughput assessment of human sperm chromatin quality.

    PubMed

    Albert, Océane; Reintsch, Wolfgang E; Chan, Peter; Robaire, Bernard

    2016-05-01

    Can we make the comet assay (single-cell gel electrophoresis) for human sperm a more accurate and informative high throughput assay? We developed a standardized automated high throughput comet (HT-COMET) assay for human sperm that improves its accuracy and efficiency, and could be of prognostic value to patients in the fertility clinic. The comet assay involves the collection of data on sperm DNA damage at the level of the single cell, allowing the use of samples from severe oligozoospermic patients. However, this makes comet scoring a low throughput procedure that renders large cohort analyses tedious. Furthermore, the comet assay comes with an inherent vulnerability to variability. Our objective is to develop an automated high throughput comet assay for human sperm that will increase both its accuracy and efficiency. The study comprised two distinct components: a HT-COMET technical optimization section based on control versus DNAse treatment analyses ( ITALIC! n = 3-5), and a cross-sectional study on 123 men presenting to a reproductive center with sperm concentrations categorized as severe oligozoospermia, oligozoospermia or normozoospermia. Sperm chromatin quality was measured using the comet assay: on classic 2-well slides for software comparison; on 96-well slides for HT-COMET optimization; after exposure to various concentrations of a damage-inducing agent, DNAse, using HT-COMET; on 123 subjects with different sperm concentrations using HT-COMET. Data from the 123 subjects were correlated to classic semen quality parameters and plotted as single-cell data in individual DNA damage profiles. We have developed a standard automated HT-COMET procedure for human sperm. It includes automated scoring of comets by a fully integrated high content screening setup that compares well with the most commonly used semi-manual analysis software. Using this method, a cross-sectional study on 123 men showed no significant correlation between sperm concentration and sperm DNA damage, confirming the existence of hidden chromatin damage in men with apparently normal semen characteristics, and a significant correlation between percentage DNA in the tail and percentage of progressively motile spermatozoa. Finally, the use of DNA damage profiles helped to distinguish subjects between and within sperm concentration categories, and allowed a determination of the proportion of highly damaged cells. The main limitations of the HT-COMET are the high, yet indispensable, investment in an automated liquid handling system and heating block to ensure accuracy, and the availability of an automated plate reading microscope and analysis software. This standardized HT-COMET assay offers many advantages, including higher accuracy and evenness due to automation of sensitive steps, a 14.4-fold increase in sample analysis capacity, and an imaging and scoring time of 1 min/well. Overall, HT-COMET offers a decrease in total experimental time of more than 90%. Hence, this assay constitutes a more efficient option to assess sperm chromatin quality, paves the way to using this assay to screen large cohorts, and holds prognostic value for infertile patients. Funded by the CIHR Institute of Human Development, Child and Youth Health (IHDCYH; RHF 100625). O.A. is a fellow supported by the Fonds de la Recherche du Québec - Santé (FRQS) and the CIHR Training Program in Reproduction, Early Development, and the Impact on Health (REDIH). B.R. is a James McGill Professor. The authors declare no conflicts of interest. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Measurement of filter paper activities of cellulase with microplate-based assay.

    PubMed

    Yu, Xiaoxiao; Liu, Yan; Cui, Yuxiao; Cheng, Qiyue; Zhang, Zaixiao; Lu, Jia Hui; Meng, Qingfan; Teng, Lirong; Ren, Xiaodong

    2016-01-01

    It is always a challenge to determine the total cellulase activity efficiently without reducing accuracy. The most common total cellulase activity assay is the filter paper assay (FPA) established by the International Union of Pure and Applied Chemistry (IUPAC). A new procedure to measure the FPA with microplate-based assay was studied in this work, which followed the main idea of IUPAC to dilute cellulase preparation to get fixed glucose release. FPAs of six cellulase preparations were determined with the microplate-based assay. It is shown that FPAs of cellulase Youtell, RCconc, R-10, Lerkam, Yishui and Sinopharm were 67.9, 46.0, 46.1, 27.4, 7.6 and 8.0 IU/ml respectively. There was no significant difference at the 95% confidence level between the FPA determined with IUPAC and the microplate-based assay. It could be concluded that the FPA could be determined by the microplate-based assay with the same accuracy and much more efficiency compared with that by IUPAC.

  19. Measurement of filter paper activities of cellulase with microplate-based assay

    PubMed Central

    Yu, Xiaoxiao; Liu, Yan; Cui, Yuxiao; Cheng, Qiyue; Zhang, Zaixiao; Lu, Jia Hui; Meng, Qingfan; Teng, Lirong; Ren, Xiaodong

    2015-01-01

    It is always a challenge to determine the total cellulase activity efficiently without reducing accuracy. The most common total cellulase activity assay is the filter paper assay (FPA) established by the International Union of Pure and Applied Chemistry (IUPAC). A new procedure to measure the FPA with microplate-based assay was studied in this work, which followed the main idea of IUPAC to dilute cellulase preparation to get fixed glucose release. FPAs of six cellulase preparations were determined with the microplate-based assay. It is shown that FPAs of cellulase Youtell, RCconc, R-10, Lerkam, Yishui and Sinopharm were 67.9, 46.0, 46.1, 27.4, 7.6 and 8.0 IU/ml respectively. There was no significant difference at the 95% confidence level between the FPA determined with IUPAC and the microplate-based assay. It could be concluded that the FPA could be determined by the microplate-based assay with the same accuracy and much more efficiency compared with that by IUPAC. PMID:26858572

  20. Newly Designed Break-Apart and ASPL-TFE3 Dual-Fusion FISH Assay Are Useful in Diagnosing Xp11.2 Translocation Renal Cell Carcinoma and ASPL-TFE3 Renal Cell Carcinoma

    PubMed Central

    Chen, Xiancheng; Yang, Yang; Gan, Weidong; Xu, Linfeng; Ye, Qing; Guo, Hongqian

    2015-01-01

    Abstract The diagnosis of Xp11.2 translocation renal cell carcinoma (tRCC), which relies on morphology and immunohistochemistry (IHC), is often either missed in the diagnosis or misdiagnosed. To improve the accuracy of diagnosis of Xp11.2 tRCC and ASPL-TFE3 renal cell carcinoma (RCC), we investigated newly designed fluorescence in situ hybridization (FISH) probes (diagnostic accuracy study). Based on the genetic characteristics of Xp11.2 tRCC and the ASPL-TFE3 RCC, a new break-apart TFE3 FISH probe and an ASPL-TFE3 dual-fusion FISH probe were designed and applied to 65 patients with RCC who were <45 years old or showed suspicious microscopic features of Xp11.2 tRCC in our hospital. To test the accuracy of the probes, we further performed reverse transcriptase–polymerase chain reaction (PCR) on 8 cases for which frozen tissues were available. Among the 65 cases diagnosed with RCC, TFE3 IHC was positive in 24 cases. Twenty-two cases were confirmed as Xp11.2 tRCC by break-apart TFE3 FISH, and 6 of these cases were further diagnosed as ASPL-TFE3 RCC by ASPL-TFE3 dual-fusion FISH detection. Importantly, reverse transcriptase–PCR showed concordant results with the results of FISH assay in the 8 available frozen cases. The break-apart and ASPL-TFE3 dual-fusion FISH assay can accurately detect the translocation of the TFE3 gene and ASPL-TFE3 fusion gene and can thus serve as a valid complementary method for diagnosing Xp11.2 tRCC and ASPL-TFE3 RCC. PMID:25984679

  1. Newly designed break-apart and ASPL-TFE3 dual-fusion FISH assay are useful in diagnosing Xp11.2 translocation renal cell carcinoma and ASPL-TFE3 renal cell carcinoma: a STARD-compliant article.

    PubMed

    Chen, Xiancheng; Yang, Yang; Gan, Weidong; Xu, Linfeng; Ye, Qing; Guo, Hongqian

    2015-05-01

    The diagnosis of Xp11.2 translocation renal cell carcinoma (tRCC), which relies on morphology and immunohistochemistry (IHC), is often either missed in the diagnosis or misdiagnosed. To improve the accuracy of diagnosis of Xp11.2 tRCC and ASPL-TFE3 renal cell carcinoma (RCC), we investigated newly designed fluorescence in situ hybridization (FISH) probes (diagnostic accuracy study).Based on the genetic characteristics of Xp11.2 tRCC and the ASPL-TFE3 RCC, a new break-apart TFE3 FISH probe and an ASPL-TFE3 dual-fusion FISH probe were designed and applied to 65 patients with RCC who were <45 years old or showed suspicious microscopic features of Xp11.2 tRCC in our hospital. To test the accuracy of the probes, we further performed reverse transcriptase-polymerase chain reaction (PCR) on 8 cases for which frozen tissues were available.Among the 65 cases diagnosed with RCC, TFE3 IHC was positive in 24 cases. Twenty-two cases were confirmed as Xp11.2 tRCC by break-apart TFE3 FISH, and 6 of these cases were further diagnosed as ASPL-TFE3 RCC by ASPL-TFE3 dual-fusion FISH detection. Importantly, reverse transcriptase-PCR showed concordant results with the results of FISH assay in the 8 available frozen cases.The break-apart and ASPL-TFE3 dual-fusion FISH assay can accurately detect the translocation of the TFE3 gene and ASPL-TFE3 fusion gene and can thus serve as a valid complementary method for diagnosing Xp11.2 tRCC and ASPL-TFE3 RCC.

  2. Polyethylene glycol versus dual sugar assay for gastrointestinal permeability analysis: is it time to choose?

    PubMed

    van Wijck, Kim; Bessems, Babs Afm; van Eijk, Hans Mh; Buurman, Wim A; Dejong, Cornelis Hc; Lenaerts, Kaatje

    2012-01-01

    Increased intestinal permeability is an important measure of disease activity and prognosis. Currently, many permeability tests are available and no consensus has been reached as to which test is most suitable. The aim of this study was to compare urinary probe excretion and accuracy of a polyethylene glycol (PEG) assay and dual sugar assay in a double-blinded crossover study to evaluate probe excretion and the accuracy of both tests. Gastrointestinal permeability was measured in nine volunteers using PEG 400, PEG 1500, and PEG 3350 or lactulose-rhamnose. On 4 separate days, permeability was analyzed after oral intake of placebo or indomethacin, a drug known to increase intestinal permeability. Plasma intestinal fatty acid binding protein and calprotectin levels were determined to verify compromised intestinal integrity after indomethacin consumption. Urinary samples were collected at baseline, hourly up to 5 hours after probe intake, and between 5 and 24 hours. Urinary excretion of PEG and sugars was determined using high-pressure liquid chromatography-evaporative light scattering detection and liquid chromatography-mass spectrometry, respectively. Intake of indomethacin increased plasma intestinal fatty acid-binding protein and calprotectin levels, reflecting loss of intestinal integrity and inflammation. In this state of indomethacin-induced gastrointestinal compromise, urinary excretion of the three PEG probes and lactulose increased compared with placebo. Urinary PEG 400 excretion, the PEG 3350/PEG 400 ratio, and the lactulose/rhamnose ratio could accurately detect indomethacin-induced increases in gastrointestinal permeability, especially within 2 hours of probe intake. Hourly urinary excretion and diagnostic accuracy of PEG and sugar probes show high concordance for detection of indomethacin-induced increases in gastrointestinal permeability. This comparative study improves our knowledge of permeability analysis in man by providing a clear overview of both tests and demonstrates equivalent performance in the current setting.

  3. An innovative SNP genotyping method adapting to multiple platforms and throughputs.

    PubMed

    Long, Y M; Chao, W S; Ma, G J; Xu, S S; Qi, L L

    2017-03-01

    An innovative genotyping method designated as semi-thermal asymmetric reverse PCR (STARP) was developed for genotyping individual SNPs with improved accuracy, flexible throughputs, low operational costs, and high platform compatibility. Multiplex chip-based technology for genome-scale genotyping of single nucleotide polymorphisms (SNPs) has made great progress in the past two decades. However, PCR-based genotyping of individual SNPs still remains problematic in accuracy, throughput, simplicity, and/or operational costs as well as the compatibility with multiple platforms. Here, we report a novel SNP genotyping method designated semi-thermal asymmetric reverse PCR (STARP). In this method, genotyping assay was performed under unique PCR conditions using two universal priming element-adjustable primers (PEA-primers) and one group of three locus-specific primers: two asymmetrically modified allele-specific primers (AMAS-primers) and their common reverse primer. The two AMAS-primers each were substituted one base in different positions at their 3' regions to significantly increase the amplification specificity of the two alleles and tailed at 5' ends to provide priming sites for PEA-primers. The two PEA-primers were developed for common use in all genotyping assays to stringently target the PCR fragments generated by the two AMAS-primers with similar PCR efficiencies and for flexible detection using either gel-free fluorescence signals or gel-based size separation. The state-of-the-art primer design and unique PCR conditions endowed STARP with all the major advantages of high accuracy, flexible throughputs, simple assay design, low operational costs, and platform compatibility. In addition to SNPs, STARP can also be employed in genotyping of indels (insertion-deletion polymorphisms). As vast variations in DNA sequences are being unearthed by many genome sequencing projects and genotyping by sequencing, STARP will have wide applications across all biological organisms in agriculture, medicine, and forensics.

  4. A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.

    PubMed

    Ji, Allena Ji; Wang, Haixing; Ziso-Qejvanaj, Enida; Zheng, Kefei; Chung, Lee Lee; Foley, Timothy; Chuang, Wei-Lien; Richards, Susan; Sung, Crystal

    2015-01-01

    Glucosylceramide, an efficacy biomarker for Gaucher Type 1 disease, exhibits poor solubility in polar solvents and whole blood which makes it difficult to prepare a homogenous blood standard. We developed a novel method using standard addition approach by spiking a small volume of analyte solution on the surface of prespotted dried blood spot. The whole spots were punched out for subsequent extraction and LC-MS/MS analysis. The assay performance met all validation acceptance criteria. Glucosylceramide concentrations in 50 paired plasma and dry blood spot samples obtained from Gaucher Type 1 patients were tested and the results demonstrated the feasibility of using the DBS method for clinical biomarker monitoring. The new approach greatly improves assay precision and accuracy.

  5. Validation of an Immunodiagnostic Assay for Detection of 13 Streptococcus pneumoniae Serotype-Specific Polysaccharides in Human Urine

    PubMed Central

    Huijts, Susanne M.; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C.; Bonten, Marc J. M.; Jansen, Kathrin U.

    2012-01-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults. PMID:22675155

  6. Validation of an immunodiagnostic assay for detection of 13 Streptococcus pneumoniae serotype-specific polysaccharides in human urine.

    PubMed

    Pride, Michael W; Huijts, Susanne M; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C; Bonten, Marc J M; Jansen, Kathrin U

    2012-08-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults.

  7. Flow cytometric immunobead assay for quantitative detection of platelet autoantibodies in immune thrombocytopenia patients.

    PubMed

    Zhai, Juping; Ding, Mengyuan; Yang, Tianjie; Zuo, Bin; Weng, Zhen; Zhao, Yunxiao; He, Jun; Wu, Qingyu; Ruan, Changgeng; He, Yang

    2017-10-23

    Platelet autoantibody detection is critical for immune thrombocytopenia (ITP) diagnosis and prognosis. Therefore, we aimed to establish a quantitative flow cytometric immunobead assay (FCIA) for ITP platelet autoantibodies evaluation. Capture microbeads coupled with anti-GPIX, -GPIb, -GPIIb, -GPIIIa and P-selectin antibodies were used to bind the platelet-bound autoantibodies complex generated from plasma samples of 250 ITP patients, 163 non-ITP patients and 243 healthy controls, a fluorescein isothiocyanate (FITC)-conjugated secondary antibody was the detector reagent and mean fluorescence intensity (MFI) signals were recorded by flow cytometry. Intra- and inter-assay variations of the quantitative FCIA assay were assessed. Comparisons of the specificity, sensitivity and accuracy between quantitative and qualitative FCIA or monoclonal antibody immobilization of platelet antigen (MAIPA) assay were performed. Finally, treatment process was monitored by our quantitative FCIA in 8 newly diagnosed ITPs. The coefficient of variations (CV) of the quantitative FCIA assay were respectively 9.4, 3.8, 5.4, 5.1 and 5.8% for anti-GPIX, -GPIb, -GPIIIa, -GPIIb and -P-selectin autoantibodies. Elevated levels of autoantibodies against platelet glycoproteins GPIX, GPIb, GPIIIa, GPIIb and P-selectin were detected by our quantitative FCIA in ITP patients compared to non-ITP patients or healthy controls. The sensitivity, specificity and accuracy of our quantitative assay were respectively 73.13, 81.98 and 78.65% when combining all 5 autoantibodies, while the sensitivity, specificity and accuracy of MAIPA assay were respectively 41.46, 90.41 and 72.81%. A quantitative FCIA assay was established. Reduced levels of platelet autoantibodies could be confirmed by our quantitative FCIA in ITP patients after corticosteroid treatment. Our quantitative assay is not only good for ITP diagnosis but also for ITP treatment monitoring.

  8. Automated quantification of Epstein-Barr Virus in whole blood of hematopoietic stem cell transplant patients using the Abbott m2000 system.

    PubMed

    Salmona, Maud; Fourati, Slim; Feghoul, Linda; Scieux, Catherine; Thiriez, Aline; Simon, François; Resche-Rigon, Matthieu; LeGoff, Jérôme

    2016-08-01

    Accurate quantification of Epstein-Barr virus (EBV) load in blood is essential for the management of post-transplant lymphoproliferative disorders. The automation of DNA extraction and amplification may improve accuracy and reproducibility. We evaluated the EBV PCR Kit V1 with fully automated DNA extraction and amplification on the m2000 system (Abbott assay). Conversion factor between copies and international units (IU), lower limit of quantification, imprecision and linearity were determined in a whole blood (WB) matrix. Results from 339 clinical WB specimens were compared with a home-brew real-time PCR assay used in our laboratory (in-house assay). The conversion factor between copies and IU was 3.22 copies/IU. The lower limit of quantification (LLQ) was 1000 copies/mL. Intra- and inter-assay coefficients of variation were 3.1% and 7.9% respectively for samples with EBV load higher than the LLQ. The comparison between Abbott assay and in-house assay showed a good concordance (kappa = 0.77). Loads were higher with the Abbott assay (mean difference = 0.62 log10 copies/mL). The EBV PCR Kit V1 assay on the m2000 system provides a reliable and easy-to-use method for quantification of EBV DNA in WB. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Biomarkers for Early Detection of Clinically Relevant Prostate Cancer: A Multi-Institutional Validation Trial

    DTIC Science & Technology

    2017-10-01

    been shown in many studies to improve predictive accuracy for cancer on initial biopsy,3,7-9 and to be correlated with more aggressive cancer at...our multi-center, prospectively accrued prostate cancer active surveillance cohort – the Canary Prostate Active Surveillance Study (PASS). We are in...objective of the study is to utilize analytically validated assays that take into account tumor heterogeneity to measure biomarkers in specimens that were

  10. Virologic versus cytologic triage of women with equivocal Pap smears: a meta-analysis of the accuracy to detect high-grade intraepithelial neoplasia.

    PubMed

    Arbyn, Marc; Buntinx, Frank; Van Ranst, Marc; Paraskevaidis, Evangelos; Martin-Hirsch, Pierre; Dillner, Joakim

    2004-02-18

    The appropriate management of women with minor cytologic lesions in their cervix is unclear. We performed a meta-analysis to assess the accuracy of human papillomavirus (HPV) DNA testing as an alternative to repeat cytology in women who had equivocal results on a previous Pap smear. Data were extracted from articles published between 1992 and 2002 that contained results of virologic and cytologic testing followed by colposcopically directed biopsy in women with an index smear showing atypical cells of undetermined significance (ASCUS). Fifteen studies were identified in which HPV triage and the histologic outcome (presence or absence of a cervical intraepithelial neoplasia of grade II or worse [CIN2+]) was documented. Nine, seven, and two studies also documented the accuracy of repeat cytology when the cutoff for abnormal cytology was set at a threshold of ASCUS or worse, low-grade squamous intraepithelial lesion (LSIL) or worse, or high-grade squamous intraepithelial lesion (HSIL) or worse, respectively. Random-effects models were used for pooling of accuracy parameters in case of interstudy heterogeneity. Differences in accuracy were assessed by pooling the ratio of the sensitivity (or specificity) of HPV testing to that of repeat cytology. The sensitivity and specificity were 84.4% (95% confidence interval [CI] = 77.6% to 91.1%) and 72.9% (95% CI = 62.5% to 83.3%), respectively, for HPV testing overall and 94.8% (95% CI = 92.7% to 96.9%) and 67.3% (95% CI = 58.2% to 76.4%), respectively, for HPV testing in the eight studies that used the Hybrid Capture II assay. Sensitivity and specificity of repeat cytology at a threshold for abnormal cytology of ASCUS or worse was 81.8% (95% CI = 73.5% to 84.3%) and 57.6% (95% CI = 49.5% to 65.7%), respectively. Repeat cytology that used higher cytologic thresholds yielded substantially lower sensitivity but higher specificity than triage with the Hybrid Capture II assay. The ratio of the sensitivity of the Hybrid Capture II assay to that of repeat cytology at a threshold of ASCUS or worse pooled from the four studies that used both triage tests was 1.16 (95% CI = 1.04 to 1.29). The specificity ratio was not statistically different from unity. The published literature indicates that the Hybrid Capture II assay has improved accuracy (higher sensitivity, similar specificity) than the repeat Pap smear using the threshold of ASCUS for an outcome of CIN2+ among women with equivocal cytologic results. The sensitivity of triage at higher cytologic cutoffs is poor.

  11. Continuous improvement of medical test reliability using reference methods and matrix-corrected target values in proficiency testing schemes: application to glucose assay.

    PubMed

    Delatour, Vincent; Lalere, Beatrice; Saint-Albin, Karène; Peignaux, Maryline; Hattchouel, Jean-Marc; Dumont, Gilles; De Graeve, Jacques; Vaslin-Reimann, Sophie; Gillery, Philippe

    2012-11-20

    The reliability of biological tests is a major issue for patient care in terms of public health that involves high economic stakes. Reference methods, as well as regular external quality assessment schemes (EQAS), are needed to monitor the analytical performance of field methods. However, control material commutability is a major concern to assess method accuracy. To overcome material non-commutability, we investigated the possibility of using lyophilized serum samples together with a limited number of frozen serum samples to assign matrix-corrected target values, taking the example of glucose assays. Trueness of the current glucose assays was first measured against a primary reference method by using human frozen sera. Methods using hexokinase and glucose oxidase with spectroreflectometric detection proved very accurate, with bias ranging between -2.2% and +2.3%. Bias of methods using glucose oxidase with spectrophotometric detection was +4.5%. Matrix-related bias of the lyophilized materials was then determined and ranged from +2.5% to -14.4%. Matrix-corrected target values were assigned and used to assess trueness of 22 sub-peer groups. We demonstrated that matrix-corrected target values can be a valuable tool to assess field method accuracy in large scale surveys where commutable materials are not available in sufficient amount with acceptable costs. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. [Importance of parathyroid SPECT and 99mTc scintigraphy, and of clinical, laboratorial, ultrasonographic and citologic correlation in the pre-operative localization of the parathyroid adenoma - pictorial assay].

    PubMed

    Oliveira, Marco Antônio Condé de; Maeda, Sérgio Setsuo; Dreyer, Patrícia; Lobo, Alberto; Andrade, Victor Piana de; Hoff, Ana O; Biscolla, Rosa Paula Mello; Smanio, Paola; Brandão, Cynthia M A; Vieira, José G

    2010-06-01

    In patients with primary hyperparathyroidism, candidates for surgical intervention, the parathyroid pre-operative localization is of fundamental importance in planning the appropriate surgical approach. The additional acquisition of SPECT and Technetium-99m images, during parathyroid scintigraphy with Sestamibi, is not common practice. Usually, only planar image acquisition, 15 minutes prior and 2 hours after radiopharmaceutical administration, is performed. In our experience, the complete protocol in parathyroid scintigraphy increases the accuracy of pre-operative parathyroid localization. The complete utilization of all available nuclear medicine methods (SPECT e 99mTc) and image interpretation in a multidisciplinary context can improve the accuracy of parathyroid scintigraphy.

  13. Two-stage bottom-up tiered approach combining several alternatives for identification of eye irritation potential of chemicals including insoluble or volatile substances.

    PubMed

    Hayashi, Kazuhiko; Mori, Taeko; Abo, Takayuki; Ooshima, Kenichi; Hayashi, Takumi; Komano, Tomoko; Takahashi, Yutaka; Sakaguchi, Hitoshi; Takatsu, Akihiko; Nishiyama, Naohiro

    2012-10-01

    For the assessment of eye irritation, one alternative test may not completely replace the rabbit Draize test. In the present study, we examined the predictive potential of a tiered approach analyzing the results from several alternatives (i.e., the Short Time Exposure (STE) test, the EpiOcular assay, the Hen's Egg Test-Chorioallantoic Membrane (HET-CAM) assay and the Bovine Corneal Opacity and Permeability (BCOP) assay) for assessing Globally Harmonized System (GHS) eye irritation categories. Fifty-six chemicals including alcohols, surfactants, and esters were selected with a balanced GHS category and a wide range of chemical classes. From a standpoint of both assessable sample numbers and predictive accuracy, the more favorable tiered approach was considered to be the two-stage bottom-up tiered approach combining the STE test, the EpiOcular assay followed by the BCOP assay (accuracy 69.6%, under prediction rate 8.9%). Moreover, a more favorable predictive capacity (accuracy 71.4%, under prediction rate 3.6%) was obtained when high volatile alcohols/esters with vapor pressures >6 kilopascal (kPa) at 25°C were evaluated with EpiOcular assay instead of the STE test. From these results, the two-stage bottom-up tiered approach combining the STE test, the EpiOcular assay followed by the BCOP assay might be a promising method for the classification of GHS eye irritation category (Not classified (NC), Category 2 (Cat. 2), and Category 1 (Cat. 1)) for a wide range of test chemicals regardless of solubility. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. The analytical validation of the Oncotype DX Recurrence Score assay

    PubMed Central

    Baehner, Frederick L

    2016-01-01

    In vitro diagnostic multivariate index assays are highly complex molecular assays that can provide clinically actionable information regarding the underlying tumour biology and facilitate personalised treatment. These assays are only useful in clinical practice if all of the following are established: analytical validation (i.e., how accurately/reliably the assay measures the molecular characteristics), clinical validation (i.e., how consistently/accurately the test detects/predicts the outcomes of interest), and clinical utility (i.e., how likely the test is to significantly improve patient outcomes). In considering the use of these assays, clinicians often focus primarily on the clinical validity/utility; however, the analytical validity of an assay (e.g., its accuracy, reproducibility, and standardisation) should also be evaluated and carefully considered. This review focuses on the rigorous analytical validation and performance of the Oncotype DX® Breast Cancer Assay, which is performed at the Central Clinical Reference Laboratory of Genomic Health, Inc. The assay process includes tumour tissue enrichment (if needed), RNA extraction, gene expression quantitation (using a gene panel consisting of 16 cancer genes plus 5 reference genes and quantitative real-time RT-PCR), and an automated computer algorithm to produce a Recurrence Score® result (scale: 0–100). This review presents evidence showing that the Recurrence Score result reported for each patient falls within a tight clinically relevant confidence interval. Specifically, the review discusses how the development of the assay was designed to optimise assay performance, presents data supporting its analytical validity, and describes the quality control and assurance programmes that ensure optimal test performance over time. PMID:27729940

  15. The analytical validation of the Oncotype DX Recurrence Score assay.

    PubMed

    Baehner, Frederick L

    2016-01-01

    In vitro diagnostic multivariate index assays are highly complex molecular assays that can provide clinically actionable information regarding the underlying tumour biology and facilitate personalised treatment. These assays are only useful in clinical practice if all of the following are established: analytical validation (i.e., how accurately/reliably the assay measures the molecular characteristics), clinical validation (i.e., how consistently/accurately the test detects/predicts the outcomes of interest), and clinical utility (i.e., how likely the test is to significantly improve patient outcomes). In considering the use of these assays, clinicians often focus primarily on the clinical validity/utility; however, the analytical validity of an assay (e.g., its accuracy, reproducibility, and standardisation) should also be evaluated and carefully considered. This review focuses on the rigorous analytical validation and performance of the Oncotype DX ® Breast Cancer Assay, which is performed at the Central Clinical Reference Laboratory of Genomic Health, Inc. The assay process includes tumour tissue enrichment (if needed), RNA extraction, gene expression quantitation (using a gene panel consisting of 16 cancer genes plus 5 reference genes and quantitative real-time RT-PCR), and an automated computer algorithm to produce a Recurrence Score ® result (scale: 0-100). This review presents evidence showing that the Recurrence Score result reported for each patient falls within a tight clinically relevant confidence interval. Specifically, the review discusses how the development of the assay was designed to optimise assay performance, presents data supporting its analytical validity, and describes the quality control and assurance programmes that ensure optimal test performance over time.

  16. Development and Validation of a Rapid (13)C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices.

    PubMed

    Matsunami, Risë K; Angelides, Kimon; Engler, David A

    2015-05-18

    There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using (13)C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and (13)C6-glucose. The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. © 2015 Diabetes Technology Society.

  17. Development and Validation of a Rapid 13C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices

    PubMed Central

    Matsunami, Risë K.; Angelides, Kimon; Engler, David A.

    2015-01-01

    Background: There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. Methods: An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using 13C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and 13C6-glucose. Results: The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. Conclusions: The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. PMID:25986627

  18. Modeling of coupled differential equations for cellular chemical signaling pathways: Implications for assay protocols utilized in cellular engineering.

    PubMed

    O'Clock, George D

    2016-08-01

    Cellular engineering involves modification and control of cell properties, and requires an understanding of fundamentals and mechanisms of action for cellular derived product development. One of the keys to success in cellular engineering involves the quality and validity of results obtained from cell chemical signaling pathway assays. The accuracy of the assay data cannot be verified or assured if the effect of positive feedback, nonlinearities, and interrelationships between cell chemical signaling pathway elements are not understood, modeled, and simulated. Nonlinearities and positive feedback in the cell chemical signaling pathway can produce significant aberrations in assay data collection. Simulating the pathway can reveal potential instability problems that will affect assay results. A simulation, using an electrical analog for the coupled differential equations representing each segment of the pathway, provides an excellent tool for assay validation purposes. With this approach, voltages represent pathway enzyme concentrations and operational amplifier feedback resistance and input resistance values determine pathway gain and rate constants. The understanding provided by pathway modeling and simulation is strategically important in order to establish experimental controls for assay protocol structure, time frames specified between assays, and assay concentration variation limits; to ensure accuracy and reproducibility of results.

  19. A Facile Stable-Isotope Dilution Method for Determination of Sphingosine Phosphate Lyase Activity

    PubMed Central

    Suh, Jung H.; Eltanawy, Abeer; Rangan, Apoorva; Saba, Julie D.

    2015-01-01

    A new technique for quantifying sphingosine phosphate lyase activity in biological samples is described. In this procedure, 2-hydrazinoquinoline is used to convert (2E)-hexadecenal into the corresponding hydrazone derivative to improve ionization efficiency and selectivity of detection. Combined utilization of liquid chromatographic separation and multiple reaction monitoring-mass spectrometry allows for simultaneous quantification of the substrate S1P and product (2E)-hexadecenal. Incorporation of (2E)-d5-hexadecenal as an internal standard improves detection accuracy and precision. A simple one-step derivatization procedure eliminates the need for further extractions. Limits of quantification for (2E)-hexadecenal and sphingosine-1-phosphate are 100 and 50 fmol, respectively. The assay displays a wide dynamic detection range useful for detection of low basal sphingosine phosphate lyase activity in wild type cells, SPL-overexpressing cell lines, and wild type mouse tissues. Compared to current methods, the capacity for simultaneous detection of sphingosine-1-phosphate and (2E)-hexadecenal greatly improves the accuracy of results and shows excellent sensitivity and specificity for sphingosine phosphate lyase activity detection. PMID:26408264

  20. Collaborative study for the validation of an improved HPLC assay for recombinant IFN-alfa-2.

    PubMed

    Jönsson, K H; Daas, A; Buchheit, K H; Terao, E

    2016-01-01

    The current European Pharmacopoeia (Ph. Eur.) texts for Interferon (IFN)-alfa-2 include a nonspecific photometric protein assay using albumin as calibrator and a highly variable cell-based assay for the potency determination of the protective effects. A request was expressed by the Official Medicines Control Laboratories (OMCLs) for improved methods for the batch control of recombinant interferon alfa-2 bulk and market surveillance testing of finished products, including those formulated with Human Serum Albumin (HSA). A HPLC method was developed at the Medical Products Agency (MPA, Sweden) for the testing of IFN-alfa-2 products. An initial collaborative study run under the Biological Standardisation Programme (BSP; study code BSP039) revealed the need for minor changes to improve linearity of the calibration curves, assay reproducibility and robustness. The goal of the collaborative study, coded BSP071, was to transfer and further validate this improved HPLC method. Ten laboratories participated in the study. Four marketed IFN-alfa-2 preparations (one containing HSA) together with the Ph. Eur. Chemical Reference Substance (CRS) for IFN-alfa-2a and IFN-alfa-2b, and in-house reference standards from two manufacturers were used for the quantitative assay. The modified method was successfully transferred to all laboratories despite local variation in equipment. The resolution between the main and the oxidised forms of IFN-alfa-2 was improved compared to the results from the BSP039 study. The improved method even allowed partial resolution of an extra peak after the principal peak. Symmetry of the main IFN peak was acceptable for all samples in all laboratories. Calibration curves established with the Ph. Eur. IFN-alfa-2a and IFN-alfa-2b CRSs showed excellent linearity with intercepts close to the origin and coefficients of determination greater than 0.9995. Assay repeatability, intermediate precision and reproducibility varied with the tested sample within acceptable ranges. Test accuracy estimated by comparing the values obtained by the participants to the declared contents determined by the manufacturers was good despite the absence of a common reference preparation. In conclusion, the present study showed that the new method is suitable, reproducible and transferable. Proposals for the revision of Ph. Eur. texts are presented.

  1. Biomarkers for Early Detection of Clinically Relevant Prostate Cancer: A Multi-Institutional Validation Trial

    DTIC Science & Technology

    2017-10-01

    mRNA and has been shown in many studies to improve predictive accuracy for cancer on initial biopsy,3,7-9 and to be correlated with more aggressive... Study (PASS). We are in the process of evaluating these three biomarker panels in tissue, blood, and urine samples with well annotated clinical and...during AS. The objective of the study is to utilize analytically validated assays that take into account tumor heterogeneity to measure biomarkers in

  2. Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.

    PubMed

    Sommer, Jurg M; Buyue, Yang; Bardan, Sara; Peters, Robert T; Jiang, Haiyan; Kamphaus, George D; Gray, Elaine; Pierce, Glenn F

    2014-11-01

    Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX® at 0.80, 0.20, or 0.05 IU/ml based on label potency. Laboratories tested blinded samples using their routine one-stage assay and in-house FIX plasma standard. The mean spike recoveries for BeneFIX (n=30 laboratories) were 121 %, 144 %, and 168 % of expected at nominal 0.80, 0.20, and 0.05 IU/ml concentrations, respectively. Corresponding rFIXFc spike recoveries were 88 %, 107 %, and 132 % of expected, respectively. All BeneFIX concentrations were consistently overestimated by most laboratories. rFIXFc activity was reagent-dependent; ellagic acid and silica gave higher values than kaolin, which underestimated rFIXFc. BeneFIX demonstrated significantly reduced chromogenic assay activity relative to one-stage assay results and nominal activity, while rFIXFc activity was close to nominal activity at three concentrations with better dilution linearity than the typical one-stage assay. In conclusion, laboratory- and reagent-specific assay variabilities were revealed, with progressively higher variability at lower FIX concentrations. Non-parallelism against the FIX plasma standard was observed in all one-stage assays with rFIXFc and BeneFIX, leading to significant overestimation of FIX activity at lower levels and generally high inter-laboratory variability. Compared to the accuracy currently achieved in clinical laboratories when measuring other rFIX products, most laboratories measured rFIXFc activity with acceptable accuracy and reliability using routine one-stage assay methods and commercially available plasma standards.

  3. High-performance liquid chromatographic method optimization for ondansetron assay in extemporaneous topical gel and in marketed products.

    PubMed

    Quamrun, Masuda; Mamoon, Rashid; Nasheed, Shams; Randy, Mullins

    2014-01-01

    The compounding and evaluation of ondansetron hydrochloride dihydrate topical gel, 2.5% w/w, were conducted in this study. The gelling agent was Carbopol 940. Ethanol 70% in purified water was used to dissolve the drug and disperse the gelling agent. A gel was formed by adding drops of 0.1 N sodium hydroxide solution. To assay this gel, we developed a simple and reproducible stability--indicating high-performance liquid chromatographic method. This method was validated for specificity, accuracy, and precision. The compounded gel was assayed in triplicate, and the average recovery was 98.3%. Ondansetron marketed products were analyzed for comparison with the compounded formulation. Assay, accuracy, and precision data of the compounded topical gel were comparable to the marketed products.

  4. Improving validation methods for molecular diagnostics: application of Bland-Altman, Deming and simple linear regression analyses in assay comparison and evaluation for next-generation sequencing

    PubMed Central

    Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L

    2018-01-01

    Aims A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R2), using R2 as the primary metric of assay agreement. However, the use of R2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. Methods We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Results Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. Conclusions The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. PMID:28747393

  5. Evaluation of the Elecsys Chagas Assay for Detection of Trypanosoma cruzi-Specific Antibodies in a Multicenter Study in Europe and Latin America.

    PubMed

    Flores-Chavez, Maria Delmans; Sambri, Vittorio; Schottstedt, Volkmar; Higuera-Escalante, Fernando Aparicio; Roessler, Dieter; Chaves, Monica; Laengin, Tina; Martinez, Alfredo; Fleischer, Bernhard

    2018-05-01

    Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi , for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% ( n = 674). Overall relative specificities were 99.90% ( n = 14,681), 100% ( n = 313), and 100% ( n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% ( n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive. Copyright © 2018 Flores-Chavez et al.

  6. Evaluation of the Elecsys Chagas Assay for Detection of Trypanosoma cruzi-Specific Antibodies in a Multicenter Study in Europe and Latin America

    PubMed Central

    Sambri, Vittorio; Schottstedt, Volkmar; Higuera-Escalante, Fernando Aparicio; Roessler, Dieter; Chaves, Monica; Laengin, Tina; Martinez, Alfredo; Fleischer, Bernhard

    2018-01-01

    ABSTRACT Serology is the preferred method to confirm a Chagas disease diagnosis and to screen blood donors. A battery of assays is often required due to the limited accuracy of single assays. The Elecsys Chagas assay is a newly developed, double-antigen sandwich assay for use on the Elecsys and cobas e immunoassay analyzers, intended to identify individuals infected with Trypanosoma cruzi, for diagnosis and screening. The performance of the Elecsys Chagas assay was evaluated in comparison with those of other widely used T. cruzi antibody assays, at multiple sites (Europe/Latin America). Relative sensitivity and specificity were assessed by using samples from blood donors, pregnant women, and hospitalized patients from regions where Chagas disease is endemic and from regions of nonendemicity. The Elecsys Chagas assay had an overall relative sensitivity of 100% (n = 674). Overall relative specificities were 99.90% (n = 14,681), 100% (n = 313), and 100% (n = 517) for samples from blood donors, pregnant women, and hospitalized patients, respectively. The analytical specificity was 99.83% (n = 594). The Elecsys Chagas assay detected T. cruzi antibodies in two World Health Organization (WHO) standard T. cruzi reference panels (panels 09/188 and 09/186) at a 1:512 dilution, corresponding to a cutoff sensitivity of approximately 1 mIU/ml. The Elecsys Chagas assay demonstrated robust performance under routine conditions at multiple sites in Europe and Latin America. In contrast to other available Chagas assays, the Elecsys assay uses a reduced number of recombinant T. cruzi antigens, resulting in a significantly smaller number of cross-reactions and improved analytical specificity while being highly sensitive. PMID:29444836

  7. Multiplexed MRM-Based Protein Quantitation Using Two Different Stable Isotope-Labeled Peptide Isotopologues for Calibration.

    PubMed

    LeBlanc, André; Michaud, Sarah A; Percy, Andrew J; Hardie, Darryl B; Yang, Juncong; Sinclair, Nicholas J; Proudfoot, Jillaine I; Pistawka, Adam; Smith, Derek S; Borchers, Christoph H

    2017-07-07

    When quantifying endogenous plasma proteins for fundamental and biomedical research - as well as for clinical applications - precise, reproducible, and robust assays are required. Targeted detection of peptides in a bottom-up strategy is the most common and precise mass spectrometry-based quantitation approach when combined with the use of stable isotope-labeled peptides. However, when measuring protein in plasma, the unknown endogenous levels prevent the implementation of the best calibration strategies, since no blank matrix is available. Consequently, several alternative calibration strategies are employed by different laboratories. In this study, these methods were compared to a new approach using two different stable isotope-labeled standard (SIS) peptide isotopologues for each endogenous peptide to be quantified, enabling an external calibration curve as well as the quality control samples to be prepared in pooled human plasma without interference from endogenous peptides. This strategy improves the analytical performance of the assay and enables the accuracy of the assay to be monitored, which can also facilitate method development and validation.

  8. Performance Evaluation of a Salivary Amylase Biosensor for Stress Assessment in Military Field Research.

    PubMed

    Peng, Henry T; Savage, Erin; Vartanian, Oshin; Smith, Shane; Rhind, Shawn G; Tenn, Catherine; Bjamason, Stephen

    2016-05-01

    A convenient biosensor for real-time measurement of biomarkers for in-field psychophysiological stress research and military operations is desirable. We evaluated a hand-held device for measuring salivary amylase as a stress marker in medical technicians undergoing combat casualty care training using two different modalities in operating room and field settings. Salivary amylase activity was measured by two biosensor methods: directly sampling saliva with a test strip placed under the tongue or pipetting a fixed volume of precollected saliva onto the test strip, followed by analyzing the sample on the strip using a biosensor. The two methods were compared for their accuracy and sensitivity to detect the stress response using an enzyme assay method as a standard. The measurements from the under-the-tongue method were not as consistent with those from the standard assay method as the values obtained from the pipetting method. The under-the-tongue method did not detect any significant increase in the amylase activity due to stress in the operating room (P > 0.1), in contrast to the significant increases observed using the pipetting method and assay method with a significance level less than 0.05 and 0.1, respectively. Furthermore, the under-the-tongue method showed no increased amylase activity in the field testing, while both the pipetting method and assay method showed increased amylase activity in the same group (P < 0.1). The accuracy and consistency of the biosensors need to be improved when used to directly measure salivary amylase activity under the tongue for stress assessment in military medical training. © 2015 Her Majesty the Queen in Right of Canada. Journal of Clinical Laboratory Analysis published by Wiley Periodicals, Inc. Reproduced with the permission DRDC Editorial Board.

  9. Evaluation of variability and quality control procedures for a receptor-binding assay for paralytic shellfish poisoning toxins.

    PubMed

    Ruberu, S R; Langlois, G W; Masuda, M; Perera, S Kusum

    2012-01-01

    The receptor-binding assay (RBA) method for determining saxatoxin (STX) and its numerous analogues, which cause paralytic shellfish poisoning (PSP) in humans, was evaluated in a single laboratory study. Each step of the assay preparation procedure including the performance of the multi-detector TopCount® instrument was evaluated for its contribution to method variability. The overall inherent RBA variability was determined to be 17%. Variability within the 12 detectors was observed; however, there was no reproducible pattern in detector performance. This observed variability among detectors could be attributed to other factors, such as pipetting errors. In an attempt to reduce the number of plates rejected due to excessive variability in the method's quality control parameters, a statistical approach was evaluated using either Grubbs' test or the Student's t-test for rejecting outliers in the measurement of triplicate wells. This approach improved the ratio of accepted versus rejected plates, saving cost and time for rerunning the assay. However, the potential reduction in accuracy and the lack of improvement in precision suggests caution when using this approach. The current study has recommended an alternate quality control procedure for accepting or rejecting plates in place of the criteria currently used in the published assay, or the alternative of outlier testing. The recommended procedure involves the development of control charts to monitor the critical parameters identified in the published method (QC sample, EC₅₀, slope of calibration curve), with the addition of a fourth critical parameter which is the top value (100% binding) of the calibration curve.

  10. Impact of Compounding Error on Strategies for Subtyping Pathogenic Bacteria

    PubMed Central

    Orfe, Lisa; Davis, Margaret A.; Lafrentz, Stacey; Kang, Min-Su

    2008-01-01

    Abstract Comparative-omics will identify a multitude of markers that can be used for intraspecific discrimination between strains of bacteria. It seems intuitive that with this plethora of markers we can construct higher resolution subtyping assays using discrete markers to define strain “barcodes.” Unfortunately, with each new marker added to an assay, overall assay robustness declines because errors are compounded exponentially. For example, the difference in accuracy of strain classification for an assay with 60 markers will change from 99.9% to 54.7% when average probe accuracy declines from 99.999% to 99.0%. To illustrate this effect empirically, we constructed a 19 probe bead-array for subtyping Listeria monocytogenes and showed that despite seemingly reliable individual probe accuracy (>97%), our best classification results at the strain level were <75%. A more robust strategy would use as few markers as possible to achieve strain discrimination. Consequently, we developed two variable number of tandem repeat (VNTR) assays (Vibrio parahaemolyticus and L. monocytogenes) and demonstrate that these assays along with a published assay (Salmonella enterica) produce robust results when products were machine scored. The discriminatory ability with four to seven VNTR loci was comparable to pulsed-field gel electrophoresis. Passage experiments showed some instability with ca. 5% of passaged lines showing evidence for new alleles within 30 days (V. parahaemolyticus and S. enterica). Changes were limited to a single locus and allele so conservative rules can be used to determine strain matching. Most importantly, VNTRs appear robust and portable and can clearly discriminate between strains with relatively few loci thereby limiting effects of compounding error. PMID:18713065

  11. Role of sampling times and serum cortisol cut-off concentrations on the routine assessment of adrenal function using the standard cosyntropin test in an academic hospital from Spain: a retrospective chart review.

    PubMed

    Ortiz-Flores, Andrés E; Santacruz, Elisa; Jiménez-Mendiguchia, Lucía; García-Cano, Ana; Nattero-Chávez, Lia; Escobar-Morreale, Héctor F; Luque-Ramírez, Manuel

    2018-05-05

    Aiming to validate the use of a single poststimulus sampling protocol for cosyntropin test short standard high-dose test (SST) in our institution, our primary objectives were (1) to determine the concordance between 30 and 60 min serum cortisol (SC) measurements during SST; and (2) to evaluate the diagnostic agreement between both sampling times when using classic or assay-specific and sex-specific SC cut-off values. The secondary objectives included (1) estimating the specificity and positive predictive value of 30 and 60 min sampling times while considering the suspected origin of adrenal insufficiency (AI); and (2) obtaining assay-specific cut-off values for SC after SST in a group of subjects with normal hypothalamic-pituitary-adrenal (HPA) axis. This is a retrospective chart review study conducted at a Spanish academic hospital from 2011 to 2015. Two groups were evaluated: (1) a main study group including 370 patients in whom SC was measured at 30 and 60 min during SST; and (2) a confirmative group that included 150 women presenting with a normal HPA axis in whom SST was conducted to rule out late-onset congenital adrenal hyperplasia. Diagnostic agreement between both sampling times was assessed by considering both classic (500 nmol/L) and assay-specific SC cut-off concentrations. Diagnostic agreement between both sampling times was greater when applying sex-specific and assay-specific cut-off values instead of the classic cut-off values. For suspected primary AI, 30 min SC determination was enough to establish a diagnosis in over 95% of cases, without missing any necessary treatment. When central AI is suspected, 60 min SC measurement was more specific, establishing a diagnosis in over 97% of cases. Sex-specific and assay-specific SC cut-off values improve the diagnostic accuracy of SST. For primary disease, a subnormal SC response at 30 min is a reliable marker of adrenal dysfunction. On the contrary, when central AI is suspected, 60 min SC measurement improves the diagnostic accuracy of the test. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. One-step immunochromatographic visual assay for anti-transglutaminase detection in organ culture system: An easy and prompt method to simplify the in vitro diagnosis of celiac disease.

    PubMed

    Di Tola, Marco; Marino, Mariacatia; Casale, Rossella; Borghini, Raffaele; Tiberti, Antonio; Donato, Giuseppe; Occhiuzzi, Umberto; Picarelli, Antonio

    2018-01-01

    Anti-tissue transglutaminase (anti-tTG) and endomysium antibodies (EMA) are detectable in duodenal culture media of celiac disease (CD) patients. To improve the management of this organ culture system, we evaluated the anti-tTG occurrence by immunochromatographic assay (ICA). A total of 103 CD patients and 41 disease controls underwent duodenal biopsy for the organ culture. In culture supernatants, IgA anti-tTG were tested by both enzyme-linked immunosorbent assay (ELISA) and ICA, IgA EMA were searched by indirect immunofluorescence analysis (iIFA). Endomysium antibodies and anti-tTG measured by ELISA were positive in culture media of all CD patients, while anti-tTG detected by ICA were positive in culture media of 87/103 CD patients. Anti-tTG ICA scores significantly correlated with anti-tTG ELISA values (r=.71, P<.0001). Sensitivity, specificity and diagnostic accuracy of anti-tTG detected by ICA were 84.5%, 100% and 88.9%, respectively. Using ICA, anti-tTG are detectable in duodenal culture media of most CD patients and the intensity of indicative lines depends on the anti-tTG concentration. Sensitivity and diagnostic accuracy achieved with ICA are lower than those obtained with ELISA but, given that the first is a more easy and prompt method, data suggest the possibility of utilizing it in the in vitro diagnosis of CD. © 2017 Wiley Periodicals, Inc.

  13. Data quality in drug discovery: the role of analytical performance in ligand binding assays

    NASA Astrophysics Data System (ADS)

    Wätzig, Hermann; Oltmann-Norden, Imke; Steinicke, Franziska; Alhazmi, Hassan A.; Nachbar, Markus; El-Hady, Deia Abd; Albishri, Hassan M.; Baumann, Knut; Exner, Thomas; Böckler, Frank M.; El Deeb, Sami

    2015-09-01

    Despite its importance and all the considerable efforts made, the progress in drug discovery is limited. One main reason for this is the partly questionable data quality. Models relating biological activity and structures and in silico predictions rely on precisely and accurately measured binding data. However, these data vary so strongly, such that only variations by orders of magnitude are considered as unreliable. This can certainly be improved considering the high analytical performance in pharmaceutical quality control. Thus the principles, properties and performances of biochemical and cell-based assays are revisited and evaluated. In the part of biochemical assays immunoassays, fluorescence assays, surface plasmon resonance, isothermal calorimetry, nuclear magnetic resonance and affinity capillary electrophoresis are discussed in details, in addition radiation-based ligand binding assays, mass spectrometry, atomic force microscopy and microscale thermophoresis are briefly evaluated. In addition, general sources of error, such as solvent, dilution, sample pretreatment and the quality of reagents and reference materials are discussed. Biochemical assays can be optimized to provide good accuracy and precision (e.g. percental relative standard deviation <10 %). Cell-based assays are often considered superior related to the biological significance, however, typically they cannot still be considered as really quantitative, in particular when results are compared over longer periods of time or between laboratories. A very careful choice of assays is therefore recommended. Strategies to further optimize assays are outlined, considering the evaluation and the decrease of the relevant error sources. Analytical performance and data quality are still advancing and will further advance the progress in drug development.

  14. Parallel Reaction Monitoring: A Targeted Experiment Performed Using High Resolution and High Mass Accuracy Mass Spectrometry

    PubMed Central

    Rauniyar, Navin

    2015-01-01

    The parallel reaction monitoring (PRM) assay has emerged as an alternative method of targeted quantification. The PRM assay is performed in a high resolution and high mass accuracy mode on a mass spectrometer. This review presents the features that make PRM a highly specific and selective method for targeted quantification using quadrupole-Orbitrap hybrid instruments. In addition, this review discusses the label-based and label-free methods of quantification that can be performed with the targeted approach. PMID:26633379

  15. Rapid identification of tomato Sw-5 resistance-breaking isolates of Tomato spotted wilt virus using high resolution melting and TaqMan SNP Genotyping assays as allelic discrimination techniques.

    PubMed

    di Rienzo, Valentina; Bubici, Giovanni; Montemurro, Cinzia; Cillo, Fabrizio

    2018-01-01

    In tomato, resistance to Tomato spotted wilt virus (TSWV) is conferred by the dominant gene, designated Sw-5. Virulent Sw-5 resistance breaking (SRB) mutants of TSWV have been reported on Sw-5 tomato cultivars. Two different PCR-based allelic discrimination techniques, namely Custom TaqMan™ SNP Genotyping and high-resolution melting (HRM) assays, were developed and compared for their ability to distinguish between avirulent (Sw-5 non-infecting, SNI) and SRB biotypes. TaqMan assays proved to be more sensitive (threshold of detection in a range of 50-70 TSWV RNA copies) and more reliable than HRM, assigning 25 TSWV isolates to their correct genotype with an accuracy of 100%. Moreover, the TaqMan SNP assays were further improved developing a rapid and simple protocol that included crude leaf extraction for RNA template preparations. On the other hand, HRM assays showed higher levels of sensitivity than TaqMan when used to co-detect both biotypes in different artificial mixtures. These diagnostic assays contributed to gain preliminary information on the epidemiology of TSWV isolates in open field conditions. In fact, the presented data suggest that SRB isolates are present as stable populations established year round, persisting on both winter (globe artichoke) and summer (tomato) crops, in the same cultivated areas of Southern Italy.

  16. Evaluation of the Abbott RealTime HCV assay for quantitative detection of hepatitis C virus RNA.

    PubMed

    Michelin, Birgit D A; Muller, Zsofia; Stelzl, Evelyn; Marth, Egon; Kessler, Harald H

    2007-02-01

    The Abbott RealTime HCV assay for quantitative detection of HCV RNA has recently been introduced. In this study, the performance of the Abbott RealTime HCV assay was evaluated and compared to the COBAS AmpliPrep/COBAS TaqMan HCV test. Accuracy, linearity, interassay and intra-assay variations were determined, and a total of 243 routine clinical samples were investigated. When accuracy of the new assay was tested, the majority of results were found to be within +/-0.5 log(10) unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve up to 1.0 x 10(6)IU/ml. The interassay variation ranged from 15% to 32%, and the intra-assay variation ranged from 5% to 8%. When clinical samples were tested by the Abbott RealTime HCV assay and the results were compared with those obtained by the COBAS AmpliPrep/COBAS TaqMan HCV test, the results for 93% of all samples with positive results by both tests were found to be within +/-1.0 log(10) unit. The viral loads for all patients measured by the Abbott and Roche assays showed a high correlation (R(2)=0.93); quantitative results obtained by the Abbott assay were found to be lower than those obtained by the Roche assay. The Abbott RealTime HCV assay proved to be suitable for use in the routine diagnostic laboratory. The time to results was similar for both of the assays.

  17. Interlaboratory variability in the quantification of new generation antiepileptic drugs based on external quality assessment data.

    PubMed

    Williams, John; Bialer, Meir; Johannessen, Svein I; Krämer, Günther; Levy, René; Mattson, Richard H; Perucca, Emilio; Patsalos, Philip N; Wilson, John F

    2003-01-01

    To assess interlaboratory variability in the determination of serum levels of new antiepileptic drugs (AEDs). Lyophilised serum samples containing clinically relevant concentrations of felbamate (FBM), gabapentin (GBP), lamotrigine (LTG), the monohydroxy derivative of oxcarbazepine (OCBZ; MHD), tiagabine (TGB), topiramate (TPM), and vigabatrin (VGB) were distributed monthly among 70 laboratories participating in the international Heathcontrol External Quality Assessment Scheme (EQAS). Assay results returned over a 15-month period were evaluated for precision and accuracy. The most frequently measured compound was LTG (65), followed by MHD (39), GBP (19), TPM (18), VGB (15), FBM (16), and TGB (8). High-performance liquid chromatography was the most commonly used assay technique for all drugs except for TPM, for which two thirds of laboratories used a commercial immunoassay. For all assay methods combined, precision was <11% for MHD, FBM, TPM, and LTG, close to 15% for GBP and VGB, and as high as 54% for TGB (p < 0.001). Mean accuracy values were <10% for all drugs other than TGB, for which measured values were on average 13.9% higher than spiked values, with a high variability around the mean (45%). No differences in precision and accuracy were found between methods, except for TPM, for which gas chromatography showed poorer accuracy compared with immunoassay and gas chromatography-mass spectrometry. With the notable exception of TGB, interlaboratory variability in the determination of new AEDs was comparable to that reported with older-generation agents. Poor assay performance is related more to individual operators than to the intrinsic characteristics of the method applied. Participation in an EQAS scheme is recommended to ensure adequate control of assay variability in therapeutic drug monitoring.

  18. Benefit of hepatitis C virus core antigen assay in prediction of therapeutic response to interferon and ribavirin combination therapy.

    PubMed

    Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa

    2005-01-01

    A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.

  19. Improving validation methods for molecular diagnostics: application of Bland-Altman, Deming and simple linear regression analyses in assay comparison and evaluation for next-generation sequencing.

    PubMed

    Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L

    2018-02-01

    A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R 2 ), using R 2 as the primary metric of assay agreement. However, the use of R 2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Genetic code translation displays a linear trade-off between efficiency and accuracy of tRNA selection.

    PubMed

    Johansson, Magnus; Zhang, Jingji; Ehrenberg, Måns

    2012-01-03

    Rapid and accurate translation of the genetic code into protein is fundamental to life. Yet due to lack of a suitable assay, little is known about the accuracy-determining parameters and their correlation with translational speed. Here, we develop such an assay, based on Mg(2+) concentration changes, to determine maximal accuracy limits for a complete set of single-mismatch codon-anticodon interactions. We found a simple, linear trade-off between efficiency of cognate codon reading and accuracy of tRNA selection. The maximal accuracy was highest for the second codon position and lowest for the third. The results rationalize the existence of proofreading in code reading and have implications for the understanding of tRNA modifications, as well as of translation error-modulating ribosomal mutations and antibiotics. Finally, the results bridge the gap between in vivo and in vitro translation and allow us to calibrate our test tube conditions to represent the environment inside the living cell.

  1. HT-COMET: a novel automated approach for high throughput assessment of human sperm chromatin quality

    PubMed Central

    Albert, Océane; Reintsch, Wolfgang E.; Chan, Peter; Robaire, Bernard

    2016-01-01

    STUDY QUESTION Can we make the comet assay (single-cell gel electrophoresis) for human sperm a more accurate and informative high throughput assay? SUMMARY ANSWER We developed a standardized automated high throughput comet (HT-COMET) assay for human sperm that improves its accuracy and efficiency, and could be of prognostic value to patients in the fertility clinic. WHAT IS KNOWN ALREADY The comet assay involves the collection of data on sperm DNA damage at the level of the single cell, allowing the use of samples from severe oligozoospermic patients. However, this makes comet scoring a low throughput procedure that renders large cohort analyses tedious. Furthermore, the comet assay comes with an inherent vulnerability to variability. Our objective is to develop an automated high throughput comet assay for human sperm that will increase both its accuracy and efficiency. STUDY DESIGN, SIZE, DURATION The study comprised two distinct components: a HT-COMET technical optimization section based on control versus DNAse treatment analyses (n = 3–5), and a cross-sectional study on 123 men presenting to a reproductive center with sperm concentrations categorized as severe oligozoospermia, oligozoospermia or normozoospermia. PARTICIPANTS/MATERIALS, SETTING, METHODS Sperm chromatin quality was measured using the comet assay: on classic 2-well slides for software comparison; on 96-well slides for HT-COMET optimization; after exposure to various concentrations of a damage-inducing agent, DNAse, using HT-COMET; on 123 subjects with different sperm concentrations using HT-COMET. Data from the 123 subjects were correlated to classic semen quality parameters and plotted as single-cell data in individual DNA damage profiles. MAIN RESULTS AND THE ROLE OF CHANCE We have developed a standard automated HT-COMET procedure for human sperm. It includes automated scoring of comets by a fully integrated high content screening setup that compares well with the most commonly used semi-manual analysis software. Using this method, a cross-sectional study on 123 men showed no significant correlation between sperm concentration and sperm DNA damage, confirming the existence of hidden chromatin damage in men with apparently normal semen characteristics, and a significant correlation between percentage DNA in the tail and percentage of progressively motile spermatozoa. Finally, the use of DNA damage profiles helped to distinguish subjects between and within sperm concentration categories, and allowed a determination of the proportion of highly damaged cells. LIMITATIONS, REASONS FOR CAUTION The main limitations of the HT-COMET are the high, yet indispensable, investment in an automated liquid handling system and heating block to ensure accuracy, and the availability of an automated plate reading microscope and analysis software. WIDER IMPLICATIONS OF THE FINDINGS This standardized HT-COMET assay offers many advantages, including higher accuracy and evenness due to automation of sensitive steps, a 14.4-fold increase in sample analysis capacity, and an imaging and scoring time of 1 min/well. Overall, HT-COMET offers a decrease in total experimental time of more than 90%. Hence, this assay constitutes a more efficient option to assess sperm chromatin quality, paves the way to using this assay to screen large cohorts, and holds prognostic value for infertile patients. STUDY FUNDING/COMPETING INTEREST(S) Funded by the CIHR Institute of Human Development, Child and Youth Health (IHDCYH; RHF 100625). O.A. is a fellow supported by the Fonds de la Recherche du Québec - Santé (FRQS) and the CIHR Training Program in Reproduction, Early Development, and the Impact on Health (REDIH). B.R. is a James McGill Professor. The authors declare no conflicts of interest. PMID:26975326

  2. Highly sensitive spectrofluorimetric determination of lomefloxacin in spiked human plasma, urine and pharmaceutical preparations.

    PubMed

    Ulu, Sevgi Tatar

    2009-09-01

    A sensitive, simple and selective spectrofluorimetric method was developed for the determination of lomefloxacin in biological fluids and pharmaceutical preparations. The method is based on the reaction between the drug and 4-chloro-7-nitrobenzodioxazole in borate buffer of pH 8.5 to yield a highly fluorescent derivative that is measured at 533 nm after excitation at 433 nm. The calibration curves were linear over the concentration ranges of 12.5-625, 15-1500 and 20-2000 ng/mL for plasma, urine and standard solution, respectively. The limits of detection were 4.0 ng/mL in plasma, 5.0 ng/mL in urine and 7.0 ng/mL in standard solution. The intra-assay accuracy and precision in plasma ranged from 0.032 to 2.40% and 0.23 to 0.36%, respectively, while inter-assay accuracy and precision ranged from 0.45 to 2.10% and 0.25 to 0.38%, respectively. The intra-assay accuracy and precision estimated on spiked samples in urine ranged from 1.27 to 4.20% and 0.12 to 0.24%, respectively, while inter-assay accuracy and precision ranged from 1.60 to 4.00% and 0.14 to 0.25%, respectively. The mean recovery of lomefloxacin from plasma and urine was 98.34 and 98.43%, respectively. The method was successfully applied to the determination of lomefloxacin in pharmaceuticals and biological fluids.

  3. Polyethylene glycol versus dual sugar assay for gastrointestinal permeability analysis: is it time to choose?

    PubMed Central

    van Wijck, Kim; Bessems, Babs AFM; van Eijk, Hans MH; Buurman, Wim A; Dejong, Cornelis HC; Lenaerts, Kaatje

    2012-01-01

    Background Increased intestinal permeability is an important measure of disease activity and prognosis. Currently, many permeability tests are available and no consensus has been reached as to which test is most suitable. The aim of this study was to compare urinary probe excretion and accuracy of a polyethylene glycol (PEG) assay and dual sugar assay in a double-blinded crossover study to evaluate probe excretion and the accuracy of both tests. Methods Gastrointestinal permeability was measured in nine volunteers using PEG 400, PEG 1500, and PEG 3350 or lactulose-rhamnose. On 4 separate days, permeability was analyzed after oral intake of placebo or indomethacin, a drug known to increase intestinal permeability. Plasma intestinal fatty acid binding protein and calprotectin levels were determined to verify compromised intestinal integrity after indomethacin consumption. Urinary samples were collected at baseline, hourly up to 5 hours after probe intake, and between 5 and 24 hours. Urinary excretion of PEG and sugars was determined using high-pressure liquid chromatography-evaporative light scattering detection and liquid chromatography-mass spectrometry, respectively. Results Intake of indomethacin increased plasma intestinal fatty acid-binding protein and calprotectin levels, reflecting loss of intestinal integrity and inflammation. In this state of indomethacin-induced gastrointestinal compromise, urinary excretion of the three PEG probes and lactulose increased compared with placebo. Urinary PEG 400 excretion, the PEG 3350/PEG 400 ratio, and the lactulose/rhamnose ratio could accurately detect indomethacin-induced increases in gastrointestinal permeability, especially within 2 hours of probe intake. Conclusion Hourly urinary excretion and diagnostic accuracy of PEG and sugar probes show high concordance for detection of indomethacin-induced increases in gastrointestinal permeability. This comparative study improves our knowledge of permeability analysis in man by providing a clear overview of both tests and demonstrates equivalent performance in the current setting. PMID:22888267

  4. A comparative study of tissue factor and kaolin on blood coagulation assays using rotational thromboelastometry and thromboelastography.

    PubMed

    Peng, Henry T; Grodecki, Richard; Rizoli, Sandro; Shek, Pang N

    2016-01-01

    Rotational thromboelastometry (ROTEM) and thromboelastography (TEG) have been increasingly used to diagnose acute coagulopathy and guide blood transfusion. The tests are routinely performed using different triggering activators such as tissue factor and kaolin, which activate different pathways yielding different results. To optimize the global blood coagulation assays using ROTEM and TEG, we conducted a comparative study on the activation methods employing tissue factor and kaolin at different concentrations as well as standard reagents as recommended by the manufacturer of each device. Key parameter values were obtained at various assay conditions to evaluate and compare coagulation and fibrinolysis profiles of citrated whole blood collected from healthy volunteers. It was found that tissue factor reduced ROTEM clotting time and TEG R, and increased ROTEM clot formation time and TEG K in a concentration-dependent manner. In addition, tissue factor affected ROTEM alpha angle, and maximum clot firmness, especially in the absence of kaolin activation, whereas both ROTEM and TEG clot lysis (LI30, CL30, and LY30) remained unaffected. Moreover, kaolin reduced ROTEM clotting time and TEG R and K, but to a lesser extent than tissue factor, in-tem and ex-tem. Correlations in all corresponding parameters between ROTEM and TEG were observed, when the same activators were used in the assays compared with lesser correlations between standard kaolin TEG and ROTEM (INTEM/EXTEM). The two types of viscoelastic point-of-care devices provide different results, depending on the triggering reagent used to perform the assay. Optimal assay condition was obtained to reduce assay time and improve assay accuracy.

  5. BRAF mutation testing in solid tumors: a methodological comparison.

    PubMed

    Weyant, Grace W; Wisotzkey, Jeffrey D; Benko, Floyd A; Donaldson, Keri J

    2014-09-01

    Solid tumor genotyping has become standard of care for the characterization of proto-oncogene mutational status, which has traditionally been accomplished with Sanger sequencing. However, companion diagnostic assays and comparable laboratory-developed tests are becoming increasingly popular, such as the cobas 4800 BRAF V600 Mutation Test and the INFINITI KRAS-BRAF assay, respectively. This study evaluates and validates the analytical performance of the INFINITI KRAS-BRAF assay and compares concordance of BRAF status with two reference assays, the cobas test and Sanger sequencing. DNA extraction from FFPE tissue specimens was performed followed by multiplex PCR amplification and fluorescent label incorporation using allele-specific primer extension. Hybridization to a microarray, signal detection, and analysis were then performed. The limits of detection were determined by testing dilutions of mutant BRAF alleles within wild-type background DNA, and accuracy was calculated based on these results. The INFINITI KRAS-BRAF assay produced 100% concordance with the cobas test and Sanger sequencing and had sensitivity equivalent to the cobas assay. The INFINITI assay is repeatable with at least 95% accuracy in the detection of mutant and wild-type BRAF alleles. These results confirm that the INFINITI KRAS-BRAF assay is comparable to traditional sequencing and the Food and Drug Administration-approved companion diagnostic assay for the detection of BRAF mutations. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  6. B cell increases and ex vivo IL-2 production as secondary endpoints for the detection of sensitizers in non-radioisotopic local lymph node assay using flow cytometry.

    PubMed

    Jung, Kyoung-Mi; Jang, Won-Hee; Lee, Yong-Kyoung; Yum, Young Na; Sohn, Soojung; Kim, Bae-Hwan; Chung, Jin-Ho; Park, Young-Ho; Lim, Kyung-Min

    2012-03-25

    Non-radioisotopic local lymph node assay (LLNA) using 5-bromo-2'-deoxyuridine (BrdU) with flow cytometry (FCM) is gaining attention since it is free from the regulatory issues in traditional LLNA (tLLNA) accompanying in vivo uses of radioisotope, (3)H-thymidine. However, there is also concern over compromised performance of non-radioisotopic LLNA, raising needs for additional endpoints to improve the accuracy. With the full 22 reference substances enlisted in OECD Test Guideline No. 429, we evaluated the performance of LLNA:BrdU-FCM along with the concomitant measurements of B/T cell ratio and ex vivo cytokine production from isolated lymph node cells (LNCs) to examine the utility of these markers as secondary endpoints. Mice (Balb/c, female) were topically treated with substances on both ears for 3 days and then, BrdU was intraperitoneally injected on day 5. After a day, lymph nodes were isolated and undergone FCM to determine BrdU incorporation and B/T cell sub-typing with B220+ and CD3e+. Ex vivo cytokine production by LNCs was measured such as IL-2, IL-4, IL-6, IL-12, IFN-γ, MCP-1, GM-CSF and TNFα. Mice treated with sensitizers showed preferential increases in B cell population and the selective production of IL-2, which matched well with the increases in BrdU incorporation. When compared with guinea pig or human data, BrdU incorporation, B cell increase and IL-2 production ex vivo could successfully identify sensitizers with the accuracy comparable to tLLNA, suggesting that these markers may be useful for improving the accuracy of LLNA:BrdU-FCM or as stand-alone non-radioisotopic endpoints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Comparison of the accuracy of Hybrid Capture II and polymerase chain reaction in detecting clinically important cervical dysplasia: a systematic review and meta-analysis

    PubMed Central

    Luu, Hung N; Dahlstrom, Kristina R; Mullen, Patricia Dolan; VonVille, Helena M; Scheurer, Michael E

    2013-01-01

    The effectiveness of screening programs for cervical cancer has benefited from the inclusion of Human papillomavirus (HPV) DNA assays; which assay to choose, however, is not clear based on previous reviews. Our review addressed test accuracy of Hybrid Capture II (HCII) and polymerase chain reaction (PCR) assays based on studies with stronger designs and with more clinically relevant outcomes. We searched OvidMedline, PubMed, and the Cochrane Library for English language studies comparing both tests, published 1985–2012, with cervical dysplasia defined by the Bethesda classification. Meta-analysis provided pooled sensitivity, specificity, and 95% confidence intervals (CIs); meta-regression identified sources of heterogeneity. From 29 reports, we found that the pooled sensitivity and specificity to detect high-grade squamous intraepithelial lesion (HSIL) was higher for HCII than PCR (0.89 [CI: 0.89–0.90] and 0.85 [CI: 0.84–0.86] vs. 0.73 [CI: 0.73–0.74] and 0.62 [CI: 0.62–0.64]). Both assays had higher accuracy to detect cervical dysplasia in Europe than in Asia-Pacific or North America (diagnostic odd ratio – dOR = 4.08 [CI: 1.39–11.91] and 4.56 [CI: 1.86–11.17] for HCII vs. 2.66 [CI: 1.16–6.53] and 3.78 [CI: 1.50–9.51] for PCR) and accuracy to detect HSIL than atypical squamous cells of undetermined significance (ASCUS)/ low-grade squamous intraepithelial lesion (LSIL) (HCII-dOR = 9.04 [CI: 4.12–19.86] and PCR-dOR = 5.60 [CI: 2.87–10.94]). For HCII, using histology as a gold standard results in higher accuracy than using cytology (dOR = 2.87 [CI: 1.31–6.29]). Based on higher test accuracy, our results support the use of HCII in cervical cancer screening programs. The role of HPV type distribution should be explored to determine the worldwide comparability of HPV test accuracy. PMID:23930214

  8. Detecting DNA methylation of the BCL2, CDKN2A and NID2 genes in urine using a nested methylation specific polymerase chain reaction assay to predict bladder cancer.

    PubMed

    Scher, Michael B; Elbaum, Michael B; Mogilevkin, Yakov; Hilbert, David W; Mydlo, Jack H; Sidi, A Ami; Adelson, Martin E; Mordechai, Eli; Trama, Jason P

    2012-12-01

    Detection of methylated DNA has been shown to be a good biomarker for bladder cancer. Bladder cancer has the highest recurrence rate of any cancer and, as such, patients are regularly monitored using invasive diagnostic techniques. As urine is easily attainable, bladder cancer is an optimal cancer to detect using DNA methylation. DNA methylation is highly specific in cancer detection. However, it is difficult to detect because of the limited amount of DNA present in the urine of patients with bladder cancer. Therefore, an improved, sensitive and noninvasive diagnostic test is needed. We developed a highly specific and sensitive nested methylation specific polymerase chain reaction assay to detect the presence of bladder cancer in small volumes of patient urine. The genes assayed for DNA methylation are BCL2, CDKN2A and NID2. The regions surrounding the DNA methylation sites were amplified in a methylation independent first round polymerase chain reaction and the amplification product from the first polymerase chain reaction was used in a real-time methylation specific polymerase chain reaction. Urine samples were collected from patients receiving treatment at Wolfson Medical Center in Holon, Israel. In a pilot clinical study using patient urine samples we were able to differentiate bladder cancer from other urogenital malignancies and nonmalignant conditions with a sensitivity of 80.9% and a specificity of 86.4%. We developed a novel methylation specific polymerase chain reaction assay for the detection and monitoring of bladder cancer using DNA extracted from patient urine. The assay may also be combined with other diagnostic tests to improve accuracy. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Concordance Between Different Amyloid Immunoassays and Visual Amyloid Positron Emission Tomographic Assessment.

    PubMed

    Janelidze, Shorena; Pannee, Josef; Mikulskis, Alvydas; Chiao, Ping; Zetterberg, Henrik; Blennow, Kaj; Hansson, Oskar

    2017-12-01

    Visual assessment of amyloid positron emission tomographic (PET) images has been approved by regulatory authorities for clinical use. Several immunoassays have been developed to measure β-amyloid (Aβ) 42 in cerebrospinal fluid (CSF). The agreement between CSF Aβ42 measures from different immunoassays and visual PET readings may influence the use of CSF biomarkers and/or amyloid PET assessment in clinical practice and trials. To determine the concordance between CSF Aβ42 levels measured using 5 different immunoassays and visual amyloid PET analysis. The study included 262 patients with mild cognitive impairment or subjective cognitive decline from the Swedish BioFINDER (Biomarkers for Identifying Neurodegenerative Disorders Early and Reliably) cohort (recruited from September 1, 2010, through December 31, 2014) who had undergone flutemetamol F 18 ([18F]flutemetamol)-labeled PET. Levels of CSF Aβ42 were analyzed using the classic INNOTEST and the newer modified INNOTEST, fully automated Lumipulse (FL), EUROIMMUN (EI), and Meso Scale Discovery (MSD) assays. Concentrations of CSF Aβ were assessed using an antibody-independent mass spectrometry-based reference measurement procedure. The concordance of CSF Aβ42 levels and Aβ42:Aβ40 and Aβ42:tau ratios with visual [18F]flutemetamol PET status. Of 262 participants (mean [SD] age, 70.9 [5.5] years), 108 were women (41.2%) and 154 were men (58.8%). The mass spectrometry-derived Aβ42 values showed higher correlations with the modified Aβ42-INNOTEST (r = 0.97), Aβ42-FL (r = 0.93), Aβ42-EI (r = 0.93), and Aβ42-MSD (r = 0.95) assays compared with the classic Aβ42-INNOTEST assay (r = 0.88; P ≤ .01). The signal in the classic Aβ42-INNOTEST assay was partly quenched by recombinant Aβ1-40 peptide. However, the classic Aβ42-INNOTEST assay showed better concordance with visual [18F]flutemetamol PET status (area under the receiver operating characteristic curve [AUC], 0.92) compared with the newer assays (AUCs, 0.87-0.89; P ≤ .01). The accuracies of the newer assays improved significantly when Aβ42:Aβ40 (AUCs, 0.93-0.95; P ≤ .01), Aβ42 to total tau (T-tau) (AUCs, 0.94; P ≤ .05), or Aβ42 to phosphorylated tau (P-tau) (AUCs, 0.94-0.95; P ≤ .001) ratios were used. A combination of the Aβ42:Aβ40 ratio and T-tau or P-tau level did not improve the accuracy compared with the ratio alone. Concentrations of CSF Aβ42 derived from the new immunoassays (modified INNOTEST, FL, EI, and MSD) may correlate better with the antibody-independent mass spectrometry-based reference measurement procedure and may show improved agreement with visual [18F]flutemetamol PET assessment when using the Aβ42:Aβ40 or Aβ42:tau ratios. These findings suggest the benefit of implementing the CSF Aβ42:Aβ40 or Aβ42:tau ratios as a biomarker of amyloid deposition in clinical practice and trials.

  10. Abbott ARCHITECT iPhenytoin assay versus similar assays for measuring free phenytoin concentrations.

    PubMed

    Tacker, Danyel Hermes; Robinson, Randy; Perrotta, Peter L

    2014-01-01

    To measure free phenytoin (FP) concentrations in filtered specimens using the Abbott ARCHITECT iPhenytoin assay and to compare results from this method with results from the Abbott TDx/FLx assays. We verified accuracy, analytic measurement range, and precision for FP measurements. For correlation and therapeutic interval studies, we used filtered calibrators, controls, proficiency-testing materials, and surplus clinical samples. After implementation, we determined proficiency testing results. The analytic measurement range was 2.0 to 25.0 micromol/L. Quality control materials (6.1, 12.6, and 20.1 micromol/L) provided mean (SD) recoveries of 96.1 (5.0%), 99.2 (5.0%), and 99.3 (5.7%), respectively, and coefficients of variation of 5.2%, 5.0%, and 5.8%, respectively. Clinical specimens produced mean (SD) FP recovery levels of 103.7 (10.6%) (bias, 0.1 [0.3] micromol/L). Altering the FP therapeutic range (4.0-8.0 micromol/L) was unnecessary. Proficiency testing yielded consistently acceptable results. Our accuracy, precision, and correlation results were similar for the TDx/FLx and ARCHITECT assays, which demonstrates that the ARCHITECT iPhenytoin assay is acceptable for clinical FP measurements.

  11. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Increasing the accuracy and scalability of the Immunofluorescence Assay for Epstein Barr Virus by inferring continuous titers from a single sample dilution.

    PubMed

    Goh, Sherry Meow Peng; Swaminathan, Muthukaruppan; Lai, Julian U-Ming; Anwar, Azlinda; Chan, Soh Ha; Cheong, Ian

    2017-01-01

    High Epstein Barr Virus (EBV) titers detected by the indirect Immunofluorescence Assay (IFA) are a reliable predictor of Nasopharyngeal Carcinoma (NPC). Despite being the gold standard for serological detection of NPC, the IFA is limited by scaling bottlenecks. Specifically, 5 serial dilutions of each patient sample must be prepared and visually matched by an evaluator to one of 5 discrete titers. Here, we describe a simple method for inferring continuous EBV titers from IFA images acquired from NPC-positive patient sera using only a single sample dilution. In the first part of our study, 2 blinded evaluators used a set of reference titer standards to perform independent re-evaluations of historical samples with known titers. Besides exhibiting high inter-evaluator agreement, both evaluators were also in high concordance with historical titers, thus validating the accuracy of the reference titer standards. In the second part of the study, the reference titer standards were IFA-processed and assigned an 'EBV Score' using image analysis. A log-linear relationship between titers and EBV Score was observed. This relationship was preserved even when images were acquired and analyzed 3days post-IFA. We conclude that image analysis of IFA-processed samples can be used to infer a continuous EBV titer with just a single dilution of NPC-positive patient sera. This work opens new possibilities for improving the accuracy and scalability of IFA in the context of clinical screening. Copyright © 2016. Published by Elsevier B.V.

  13. Utilizing Low-Volume Aqueous Acoustic Transfer with the Echo 525 to Enable Miniaturization of qRT-PCR Assay.

    PubMed

    Agrawal, Sony; Cifelli, Steven; Johnstone, Richard; Pechter, David; Barbey, Deborah A; Lin, Karen; Allison, Tim; Agrawal, Shree; Rivera-Gines, Aida; Milligan, James A; Schneeweis, Jonathan; Houle, Kevin; Struck, Alice J; Visconti, Richard; Sills, Matthew; Wildey, Mary Jo

    2016-02-01

    Quantitative reverse transcription PCR (qRT-PCR) is a valuable tool for characterizing the effects of inhibitors on viral replication. The amplification of target viral genes through the use of specifically designed fluorescent probes and primers provides a reliable method for quantifying RNA. Due to reagent costs, use of these assays for compound evaluation is limited. Until recently, the inability to accurately dispense low volumes of qRT-PCR assay reagents precluded the routine use of this PCR assay for compound evaluation in drug discovery. Acoustic dispensing has become an integral part of drug discovery during the past decade; however, acoustic transfer of microliter volumes of aqueous reagents was time consuming. The Labcyte Echo 525 liquid handler was designed to enable rapid aqueous transfers. We compared the accuracy and precision of a qPCR assay using the Labcyte Echo 525 to those of the BioMek FX, a traditional liquid handler, with the goal of reducing the volume and cost of the assay. The data show that the Echo 525 provides higher accuracy and precision compared to the current process using a traditional liquid handler. Comparable data for assay volumes from 500 nL to 12 µL allowed the miniaturization of the assay, resulting in significant cost savings of drug discovery and process streamlining. © 2015 Society for Laboratory Automation and Screening.

  14. Development and Analytical Validation of an Immunoassay for Quantifying Serum Anti-Pertussis Toxin Antibodies Resulting from Bordetella pertussis Infection ▿

    PubMed Central

    Menzies, Sandra L.; Kadwad, Vijay; Pawloski, Lucia C.; Lin, Tsai-Lien; Baughman, Andrew L.; Martin, Monte; Tondella, Maria Lucia C.; Meade, Bruce D.

    2009-01-01

    Adequately sensitive and specific methods to diagnose pertussis in adolescents and adults are not widely available. Currently, no Food and Drug Administration-approved diagnostic assays are available for the serodiagnosis of Bordetella pertussis. Since concentrations of B. pertussis-specific antibodies tend to be high during the later phases of disease, a simple, rapid, easily transferable serodiagnostic test was developed. This article describes test development, initial evaluation of a prototype kit enzyme-linked immunosorbent assay (ELISA) in an interlaboratory collaborative study, and analytical validation. The data presented here demonstrate that the kit met all prespecified criteria for precision, linearity, and accuracy for samples with anti-pertussis toxin (PT) immunoglobulin G (IgG) antibody concentrations in the range of 50 to 150 ELISA units (EU)/ml, the range believed to be most relevant for serodiagnosis. The assay met the precision and linearity criteria for a wider range, namely, from 50 to 200 EU/ml; however, the accuracy criterion was not met at 200 EU/ml. When the newly adopted World Health Organization International Standard for pertussis antiserum (human) reference reagent was used to evaluate accuracy, the accuracy criteria were met from 50 to 200 international units/ml. In conclusion, the IgG anti-PT ELISA met all assay validation parameters within the range considered most relevant for serodiagnosis. This ELISA was developed and analytically validated as a user-friendly kit that can be used in both qualitative and quantitative formats. The technology for producing the kit is transferable to public health laboratories. PMID:19864485

  15. Ultrasensitive immunochromatographic assay for the simultaneous detection of five chemicals in drinking water.

    PubMed

    Xing, Changrui; Liu, Liqiang; Song, Shanshan; Feng, Min; Kuang, Hua; Xu, Chuanlai

    2015-04-15

    In this paper, we describe the development of a multicomponent lateral-flow assay based on an antibody-antigen reaction for the rapid and simultaneous detection of trace contaminants in water, including a heavy metal, algal toxin, antibiotic, hormone, and pesticide. The representative analytes chosen for the study were lead (Pb(II), microcystin-leucine-arginine (MC-LR), chloramphenicol (CAP), testosterone (T), and chlorothalonil (CTN). Five different antigens were immobilized separately in five test lines on a nitrocellulose membrane. The monoclonal antibodies specifically recognized the corresponding antigens, and there was no cross-reactivity between the antibodies in the detection assay. Samples or standards containing the five analytes were preincubated with the freeze-dried colloidal-gold-labeled monoclonal antibody conjugates to improve the sensitivity of the assay. The results were obtained within 20min with a paper-based sensor. The cut-off values for the strip test were 4ng/mL for Pb(II), 1ng/mL for MC-LR, 0.1ng/mL for CAP, 5ng/mL for T, and 5ng/mL for CTN. The assay was evaluated using spiked water samples, and the accuracy and reproducibility of the results were good. In summary, this lateral-flow device provides an effective and rapid method for the onsite detection of multiple contaminants in water samples, with no treatment or devices required. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Highly sensitive troponin T for risk stratification of acutely destabilized heart failure.

    PubMed

    Pascual-Figal, Domingo A; Casas, Teresa; Ordonez-Llanos, Jordi; Manzano-Fernández, Sergio; Bonaque, Juan C; Boronat, Miguel; Muñoz-Esparza, Carmen; Valdés, Mariano; Januzzi, James L

    2012-06-01

    A highly sensitive assay for troponin T (hsTnT) has been recently developed, which allows for the detection of even minor myocardial necrosis with high precision. It remains unexplored whether hsTnT provides incremental prognostic accuracy beyond conventional (c)TnT in patients with acutely decompensated heart failure (ADHF). A total of 202 consecutive patients admitted with ADHF and without criteria for acute myocardial infarction were studied. Troponin T was measured using the highly sensitive assay and compared with the conventional method. Patients were clinically followed up at a median of 406 days, with a primary outcome measure of all-cause mortality. The high-sensitive assay detected measurable TnT in 98% of patients vs 56% for cTnT; 81% had an hsTnT above the 99th percentile for a healthy reference population, and it reclassified 60% of those with undetectable cTnT. Both TnT methods predicted the risk of death in adjusted multivariable Cox regression analyses, without a superiority of hsTnT over cTnT in the entire population (area under the curve 0.67 vs 0.71, P = .2). Among patients with a cTnT below 0.03 ng/mL (the lowest cut-point with <10% imprecision; n = 134), solely hsTnT improved the prediction of death over clinical risk factors (relative integrated discrimination improvement +36%, P = .01) and hsTnT above 20 pg/mL identified a significant higher risk of death (hazard ratio 4.7, 95% CI 1.6-13.8, P = .005). Among patients with ADHF, myocardial necrosis (as detected with the hsTnT assay) was nearly ubiquitous. The highly sensitive assay for TnT provides comparable prognostic information to cTnT overall, but among those in whom the cTnT method was less precise or frankly negative, the hsTnT assay provided prognostic information. Copyright © 2012 Mosby, Inc. All rights reserved.

  17. Diagnostic accuracy and turnaround time of the Xpert MTB/RIF assay in routine clinical practice.

    PubMed

    Kwak, Nakwon; Choi, Sun Mi; Lee, Jinwoo; Park, Young Sik; Lee, Chang-Hoon; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Yim, Jae-Joon

    2013-01-01

    The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of pulmonary tuberculosis (PTB) and detection of rifampicin resistance were calculated. In addition, TAT of Xpert MTB/RIF assay was compared with those of other tests. Total 681 patients in whom Xpert MTB/RIF assay was requested were included in the analysis. The sensitivity, specificity, PPV and NPV of Xpert MTB/RIF assay for diagnosis of PTB were 79.5% (124/156), 100.0% (505/505), 100.0% (124/124) and 94.0% (505/537), respectively. Those for the detection of rifampicin resistance were 57.1% (8/14), 100.0% (113/113), 100.0% (8/8) and 94.9% (113/119), respectively. The median TAT of Xpert MTB/RIF assay to the report of results and results confirmed by physicians in outpatient settings were 0 (0-1) and 6 (3-7) days, respectively. Median time to treatment after initial evaluation was 7 (4-9) days in patients with Xpert MTB/RIF assay, but was 21 (7-33.5) days in patients without Xpert MTB/RIF assay. Xpert MTB/RIF assay showed acceptable sensitivity and excellent specificity for the diagnosis of PTB and detection of rifampicin resistance in areas with intermediate TB burden. Additionally, the assay decreased time to the initiation of anti-TB drugs through shorter TAT.

  18. Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice

    PubMed Central

    Kwak, Nakwon; Choi, Sun Mi; Lee, Jinwoo; Park, Young Sik; Lee, Chang-Hoon; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Yim, Jae-Joon

    2013-01-01

    The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of pulmonary tuberculosis (PTB) and detection of rifampicin resistance were calculated. In addition, TAT of Xpert MTB/RIF assay was compared with those of other tests. Total 681 patients in whom Xpert MTB/RIF assay was requested were included in the analysis. The sensitivity, specificity, PPV and NPV of Xpert MTB/RIF assay for diagnosis of PTB were 79.5% (124/156), 100.0% (505/505), 100.0% (124/124) and 94.0% (505/537), respectively. Those for the detection of rifampicin resistance were 57.1% (8/14), 100.0% (113/113), 100.0% (8/8) and 94.9% (113/119), respectively. The median TAT of Xpert MTB/RIF assay to the report of results and results confirmed by physicians in outpatient settings were 0 (0–1) and 6 (3–7) days, respectively. Median time to treatment after initial evaluation was 7 (4–9) days in patients with Xpert MTB/RIF assay, but was 21 (7–33.5) days in patients without Xpert MTB/RIF assay. Xpert MTB/RIF assay showed acceptable sensitivity and excellent specificity for the diagnosis of PTB and detection of rifampicin resistance in areas with intermediate TB burden. Additionally, the assay decreased time to the initiation of anti-TB drugs through shorter TAT. PMID:24204834

  19. Evaluation of a cow-side milk progesterone assay and assessment of the positive predictive value of oestrus diagnosis by dairy farmers in New South Wales.

    PubMed

    Ingenhoff, L; Hall, E; House, J K

    2016-12-01

    The three objectives of this study were to determine the positive predictive value (PPV) of oestrus diagnosis (heat detection accuracy) by dairy farmers, calculate the diagnostic sensitivity and specificity of the P4 Rapid milk progesterone assay for detecting a corpus luteum and evaluate the economics of using a cow-side milk progesterone assay designed to aid oestrus diagnosis. Milk samples were collected from 752 cows diagnosed in oestrus by farm personnel on 14 dairy farms. Samples were tested using the P4 Rapid milk progesterone assay to estimate the PPV of oestrus diagnosis at each farm and a crude pooled mean of PPV of oestrus diagnosis across all farms. A further 156 milk samples were collected from cows with luteal tissue status determined by transrectal ultrasound and tested by the P4 Rapid assay to enable calculation of the sensitivity and specificity of the P4 Rapid assay. For pooled farm samples, the PPV was 97.0%, with a range between farms of 88.9-100%. Sensitivity of the P4 Rapid milk progesterone assay for detecting a corpus luteum was 90.1% and specificity was 98.7%. Misclassification of oestrus in cows previously identified as pregnant was the most common cause of false-positive oestrus diagnoses by farm personnel. Routine testing of milk progesterone in all cows diagnosed in oestrus is not economically justified and may even slightly reduce submission rates; conversely, strategic use of cow-side milk progesterone assays can improve herd reproductive performance by facilitating decisions on whether to rebreed cows previously diagnosed as pregnant. © 2016 Australian Veterinary Association.

  20. New diagnostic modalities in the diagnosis of heart failure.

    PubMed Central

    Mitchell, Judith E.; Palta, Sanjeev

    2004-01-01

    Heart failure (HF) is the one cardiovascular disease that is increasing in prevalence in the United States. As the population continues to age, the incidence will certainly be amplified. However, some studies have shown that HF is correctly diagnosed initially in only 50% of affected patients. Despite the use of history, physical examination, echocardiogram, and chest x-ray, the percentage of correct initial diagnosis of HF is low. Recognizing the symptoms of HF decompensations is often problematic because other diagnoses can mimic them. There are two new diagnostic modalities that offer promise in improving HF diagnostic accuracy and identifying early HF decompensations. These diagnostic modalities include tests utilizing impedance cardiography and the B-type natriuretic peptide assay. They have the potential of increasing the accuracy of HF diagnosis and guide pharmacological treatment in the inpatient and outpatient settings. They may also assist in the recognition (or prediction) of acute HF decompensations. Images Figure 2 PMID:15586645

  1. Quality of Human Immunodeficiency Virus Viral Load Testing in Australia

    PubMed Central

    Best, Susan J.; Gust, Anthony P.; Johnson, Elizabeth I. M.; McGavin, Catherine H.; Dax, Elizabeth M.

    2000-01-01

    This study determined the proficiencies of laboratories measuring human immunodeficiency virus type 1 (HIV-1) viral loads and the accuracies of two assays used for HIV-1 viral load measurement in Australia and investigated the variability of the new versions of these assays. Quality assessment program panels containing (i) dilutions of HIV-1 subtype B, (ii) replicates of identical samples of HIV-1 subtype B, and (iii) samples of subtype E and B were tested by laboratories. Total variability (within and between laboratories) was tested with quality control samples. The coefficients of variation (CVs) for the Roche AMPLICOR HIV-1 MONITOR version (v) 1.0 and Chiron Quantiplex bDNA 2.0 assays ranged from 53 to 87% and 22 to 31%, respectively. The widespread occurrence of invalid runs with the AMPLICOR HIV-1 MONITOR 1.0 assay was identified. The CVs of the new versions of the assays were 82 to 86% for the AMPLICOR HIV-1 MONITOR v 1.5 assay and 16 to 23% for the Quantiplex bDNA 3.0 assay. For virus dilution samples, all but 5 of 19 laboratories obtained results within 2 standard deviations of the mean. The Quantiplex bDNA 2.0 assay reported values lower than those reported by the AMPLICOR HIV-1 MONITOR version 1.0 assay for samples containing HIV-1 subtype B, whereas the reverse was true for subtype E. Identification and resolution of the problem of invalid runs markedly improved the quality of HIV-1 viral load testing. The variability observed between laboratories and between assays, even the most recent versions, dictates that monitoring of viral load in an individual should always be by the same laboratory and by the same assay. Results for an individual which differ by less than 0.5 log10 HIV-1 RNA copy number/ml should not be considered clinically significant. PMID:11060062

  2. Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis

    PubMed Central

    Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.

    2014-01-01

    Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240

  3. The Case for Laboratory Developed Procedures

    PubMed Central

    Sabatini, Linda M.; Tsongalis, Gregory J.; Caliendo, Angela M.; Olsen, Randall J.; Ashwood, Edward R.; Bale, Sherri; Benirschke, Robert; Carlow, Dean; Funke, Birgit H.; Grody, Wayne W.; Hayden, Randall T.; Hegde, Madhuri; Lyon, Elaine; Pessin, Melissa; Press, Richard D.; Thomson, Richard B.

    2017-01-01

    An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories. PMID:28815200

  4. A blood tumor marker combination assay produces high sensitivity and specificity for cancer according to the natural history.

    PubMed

    Kobayashi, Tsuneo

    2018-03-01

    Diagnosis using a specific tumor marker is difficult because the sensitivity of this detection method is under 20%. Herein, a tumor marker combination assay, combining growth-related tumor marker and associated tumor marker (Cancer, 73(7), 1994), was employed. This double-blind tumor marker combination assay (TMCA) showed 87.5% sensitivity as the results, but a low specificity, ranging from 30 to 76%. To overcome this low specificity, we exploited complex markers, a multivariate analysis and serum fractionation by biochemical biopsy. Thus, in this study, a combination of new techniques was used to re-evaluate these serum samples. Three serum panels, containing 90, 120, and 97 samples were obtained from the Mayo Clinic. The final results showed 80-90% sensitivity, 84-85% specificity, and 83-88% accuracy. We demonstrated a notable tumor marker combination assay with high accuracy. This TMCA should be applicable for primary cancer detection and recurrence prevention. © 2018 The Author. Cancer Medicine published by John Wiley & Sons Ltd.

  5. Simultaneous determination of five systemic azoles in plasma by high-performance liquid chromatography with ultraviolet detection.

    PubMed

    Gordien, Jean-Baptiste; Pigneux, Arnaud; Vigouroux, Stephane; Tabrizi, Reza; Accoceberry, Isabelle; Bernadou, Jean-Marc; Rouault, Audrey; Saux, Marie-Claude; Breilh, Dominique

    2009-12-05

    A simple, specific and automatable HPLC assay was developed for a simultaneous determination of systemic azoles (fluconazole, posaconazole, voriconazole, itraconazole and its metabolite hydroxyl-itraconazole, and ketoconazole) in plasma. The major advantage of this assay was sample preparation by a fully automatable solid phase extraction with Varian Plexa cartridges. C6-phenyl column was used for chromatographic separation, and UV detection was set at a wavelength of 260 nm. Linezolid was used as an internal standard. The assay was specific and linear over the concentration range of 0.05 to 40 microg/ml excepted for fluconazole which was between 0.05 and 100 microg/ml, and itraconazole between 0.1 and 40 microg/ml. Validation data for accuracy and precision for intra- and inter-day were good and satisfied FDA's guidance: CV between 0.24% and 11.66% and accuracy between 93.8% and 108.7% for all molecules. This assay was applied to therapeutic drug monitoring on patients hospitalized in intensive care and onco-hematologic units.

  6. Development of MMC Gamma Detectors for Nuclear Analysis

    NASA Astrophysics Data System (ADS)

    Bates, C. R.; Pies, C.; Kempf, S.; Gastaldo, L.; Fleischmann, A.; Enss, C.; Friedrich, S.

    2014-09-01

    Non-destructive assay (NDA) of nuclear materials would benefit from gamma detectors with improved energy resolution in cases where line overlap in current Ge detectors limits NDA accuracy. We are developing metallic magnetic calorimeter gamma-detectors for this purpose by electroplating 150 m thick Au absorbers into microfabricated molds on top of Au:Er sensors. Initial tests under non-optimized conditions show an energy resolution of 200 eV FWHM at 60 keV. Monte Carlo simulations illustrate that this resolution is starting to be sufficient for direct detection of Pu in plutonium separated from spent nuclear fuel.

  7. DNA-mounted self-assembly: new approaches for genomic analysis and SNP detection.

    PubMed

    Bichenkova, Elena V; Lang, Zhaolei; Yu, Xuan; Rogert, Candelaria; Douglas, Kenneth T

    2011-01-01

    This article presents an overview of new emerging approaches for nucleic acid detection via hybridization techniques that can potentially be applied to genomic analysis and SNP identification in clinical diagnostics. Despite the availability of a diverse variety of SNP genotyping technologies on the diagnostic market, none has truly succeeded in dominating its competitors thus far. Having been designed for specific diagnostic purposes or clinical applications, each of the existing bio-assay systems (briefly outlined here) is usually limited to a relatively narrow aspect or format of nucleic acid detection, and thus cannot entirely satisfy all the varieties of commercial requirements and clinical demands. This drives the diagnostic sector to pursue novel, cost-effective approaches to ensure rapid and reliable identification of pathogenic or hereditary human diseases. Hence, the purpose of this review is to highlight some new strategic directions in DNA detection technologies in order to inspire development of novel molecular diagnostic tools and bio-assay systems with superior reliability, reproducibility, robustness, accuracy and sensitivity at lower assay cost. One approach to improving the sensitivity of an assay to confidently discriminate between single point mutations is based on the use of target assembled, split-probe systems, which constitutes the main focus of this review. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. Development of a multiplex real-time PCR for the simultaneous detection of herpes simplex and varicella zoster viruses in cerebrospinal fluid and lesion swab specimens.

    PubMed

    Wong, Anita A; Pabbaraju, Kanti; Wong, Sallene; Tellier, Raymond

    2016-03-01

    Herpes simplex viruses (HSV) and varicella zoster virus (VZV) can have very similar and wide-ranging clinical presentations. Rapid identification is necessary for timely antiviral therapy, especially with infections involving the central nervous system, neonates, and immunocompromised individuals. Detection of HSV-1, HSV-2 and VZV was combined into one real-time PCR reaction utilizing hydrolysis probes. The assay was validated on the LightCycler(®) (Roche) and Applied Biosystems 7500 Real-Time PCR System (Thermo Fisher Scientific Inc.) to detect alphaherpesviruses in cerebral spinal fluid (CSF) and lesion swab specimens, respectively. Validation data on blood and tissue samples are also presented. The multiplex assay showed excellent sensitivity, specificity and reproducibility when compared to two singleplex real-time PCR assays for CSF samples and direct fluorescent antigen/culture for lesion swab samples. Implementation of the multiplex assay has facilitated improved sensitivity and accuracy as well as reduced turn-around-times and costs. The results from a large data set of 16,622 prospective samples tested between August 16, 2012 to February 1, 2014 at the Provincial Laboratory for Public Health (Alberta, Canada) are presented here. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Benefit of Hepatitis C Virus Core Antigen Assay in Prediction of Therapeutic Response to Interferon and Ribavirin Combination Therapy

    PubMed Central

    Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa

    2005-01-01

    A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay. PMID:15634970

  10. Bioassays for TSH Receptor Autoantibodies, from FRTL-5 Cells to TSH Receptor-LH/CG Receptor Chimeras: The Contribution of Leonard D. Kohn.

    PubMed

    Giuliani, Cesidio; Saji, Motoyasu; Bucci, Ines; Napolitano, Giorgio

    2016-01-01

    Since the discovery 60 years ago of the "long-acting thyroid stimulator" by Adams and Purves, great progress has been made in the detection of thyroid-stimulating hormone (TSH) receptor (TSHR) autoantibodies (TRAbs) in Graves' disease. Today, commercial assays are available that can detect TRAbs with high accuracy and provide diagnostic and prognostic evaluation of patients with Graves' disease. The present review focuses on the development of TRAbs bioassays, and particularly on the role that Leonard D. Kohn had in this. Indeed, 30 years ago, the Kohn group developed a bioassay based on the use of FRTL-5 cells that was characterized by high reproducibility, feasibility, and diagnostic accuracy. Using this FRTL-5 bioassay, Kohn and his colleagues were the first to develop monoclonal antibodies (moAbs) against the TSHR. Furthermore, they demonstrated the multifaceted functional nature of TRAbs in patients with Graves' disease, with the identification of stimulating and blocking TRAbs, and even antibodies that activated pathways other than cAMP. After the cloning of the TSHR, the Kohn laboratory constructed human TSHR-rat luteinizing hormone/chorionic gonadotropin receptor chimeras. This paved the way to a new bioassay based on the use of non-thyroid cells transfected with the Mc4 chimera. The new Mc4 bioassay is characterized by high diagnostic and prognostic accuracy, greater than for other assays. The availability of a commercial kit based on the Mc4 chimera is spreading the use of this assay worldwide, indicating its benefits for these patients with Graves' disease. This review also describes the main contributions made by other researchers in TSHR molecular biology and TRAbs assay, especially with the development of highly potent moAbs. A comparison of the diagnostic accuracies of the main TRAbs assays, as both immunoassays and bioassays, is also provided.

  11. Bioassays for TSH Receptor Autoantibodies, from FRTL-5 Cells to TSH Receptor–LH/CG Receptor Chimeras: The Contribution of Leonard D. Kohn

    PubMed Central

    Giuliani, Cesidio; Saji, Motoyasu; Bucci, Ines; Napolitano, Giorgio

    2016-01-01

    Since the discovery 60 years ago of the “long-acting thyroid stimulator” by Adams and Purves, great progress has been made in the detection of thyroid-stimulating hormone (TSH) receptor (TSHR) autoantibodies (TRAbs) in Graves’ disease. Today, commercial assays are available that can detect TRAbs with high accuracy and provide diagnostic and prognostic evaluation of patients with Graves’ disease. The present review focuses on the development of TRAbs bioassays, and particularly on the role that Leonard D. Kohn had in this. Indeed, 30 years ago, the Kohn group developed a bioassay based on the use of FRTL-5 cells that was characterized by high reproducibility, feasibility, and diagnostic accuracy. Using this FRTL-5 bioassay, Kohn and his colleagues were the first to develop monoclonal antibodies (moAbs) against the TSHR. Furthermore, they demonstrated the multifaceted functional nature of TRAbs in patients with Graves’ disease, with the identification of stimulating and blocking TRAbs, and even antibodies that activated pathways other than cAMP. After the cloning of the TSHR, the Kohn laboratory constructed human TSHR–rat luteinizing hormone/chorionic gonadotropin receptor chimeras. This paved the way to a new bioassay based on the use of non-thyroid cells transfected with the Mc4 chimera. The new Mc4 bioassay is characterized by high diagnostic and prognostic accuracy, greater than for other assays. The availability of a commercial kit based on the Mc4 chimera is spreading the use of this assay worldwide, indicating its benefits for these patients with Graves’ disease. This review also describes the main contributions made by other researchers in TSHR molecular biology and TRAbs assay, especially with the development of highly potent moAbs. A comparison of the diagnostic accuracies of the main TRAbs assays, as both immunoassays and bioassays, is also provided. PMID:27504107

  12. Age-Related Differences in Diagnostic Accuracy of Plasma GFAP and Tau For Identifying Acute Intracranial Trauma on CT: A TRACK-TBI Study.

    PubMed

    Gardner, Raquel C; Rubenstein, Richard; Wang, Kevin K W; Korley, Frederick Kofi; Yue, John K; Yuh, Esther Lim; Mukherjee, Pratik; Valadka, Alex; Okonkwo, David O; Diaz-Arrastia, Ramon; Manley, Geoffrey

    2018-05-02

    Plasma tau and glial fibrillary acidic protein (GFAP) are promising biomarkers for identifying traumatic brain injury (TBI) patients with intracranial trauma on CT. Accuracy in older adults with mild TBI (mTBI), the fastest growing TBI population, is unknown. Our aim was to assess for age-related differences in diagnostic accuracy of plasma tau and GFAP for identifying intracranial trauma on CT. Samples from 169 patients (age <40y [n=79], age 40-59y [n=60], age 60y+ [n=30]), a subset of patients from the TRACK-TBI Pilot study, who presented with mTBI (GCS 13-15), received head CT, and consented to blood-draw within 24h of injury were assayed for hyperphosphorylated-tau (P-tau), total-tau (T-tau; both via amplification-linked enhanced immunoassay using multi-arrayed fiberoptics), and GFAP (via sandwich enzyme-linked immunosorbent assay). P-tau, T-tau, P-tau:T-tau ratio, and GFAP concentration were significantly associated with CT findings. Overall, discriminative ability declined with increasing age for all assays, but this decline was only statistically significant for GFAP (area under the receiver operating characteristic curve [AUC]: old 0.73[ref] vs. young 0.93[p=0.037] or middle-aged 0.92[p<0.050]). P-tau concentration showed consistently highest diagnostic accuracy across all age-groups (AUC: old 0.84[ref] vs. young 0.95[p=0.274] or middle-aged 0.93[p=0.367]). Comparison of models including P-tau alone versus P-tau plus GFAP revealed significant added value of GFAP. In conclusion, the GFAP assay was less accurate for identifying intracranial trauma on CT among older versus younger mTBI patients. Mechanisms of this age-related difference, including role of assay methodology, specific TBI neuroanatomy, pre-existing conditions, and anti-thrombotic use warrant further study.

  13. The diagnostic accuracy of serological tests for Lyme borreliosis in Europe: a systematic review and meta-analysis.

    PubMed

    Leeflang, M M G; Ang, C W; Berkhout, J; Bijlmer, H A; Van Bortel, W; Brandenburg, A H; Van Burgel, N D; Van Dam, A P; Dessau, R B; Fingerle, V; Hovius, J W R; Jaulhac, B; Meijer, B; Van Pelt, W; Schellekens, J F P; Spijker, R; Stelma, F F; Stanek, G; Verduyn-Lunel, F; Zeller, H; Sprong, H

    2016-03-25

    Interpretation of serological assays in Lyme borreliosis requires an understanding of the clinical indications and the limitations of the currently available tests. We therefore systematically reviewed the accuracy of serological tests for the diagnosis of Lyme borreliosis in Europe. We searched EMBASE en MEDLINE and contacted experts. Studies evaluating the diagnostic accuracy of serological assays for Lyme borreliosis in Europe were eligible. Study selection and data-extraction were done by two authors independently. We assessed study quality using the QUADAS-2 checklist. We used a hierarchical summary ROC meta-regression method for the meta-analyses. Potential sources of heterogeneity were test-type, commercial or in-house, Ig-type, antigen type and study quality. These were added as covariates to the model, to assess their effect on test accuracy. Seventy-eight studies evaluating an Enzyme-Linked ImmunoSorbent assay (ELISA) or an immunoblot assay against a reference standard of clinical criteria were included. None of the studies had low risk of bias for all QUADAS-2 domains. Sensitivity was highly heterogeneous, with summary estimates: erythema migrans 50% (95% CI 40% to 61%); neuroborreliosis 77% (95% CI 67% to 85%); acrodermatitis chronica atrophicans 97% (95% CI 94% to 99%); unspecified Lyme borreliosis 73% (95% CI 53% to 87%). Specificity was around 95% in studies with healthy controls, but around 80% in cross-sectional studies. Two-tiered algorithms or antibody indices did not outperform single test approaches. The observed heterogeneity and risk of bias complicate the extrapolation of our results to clinical practice. The usefulness of the serological tests for Lyme disease depends on the pre-test probability and subsequent predictive values in the setting where the tests are being used. Future diagnostic accuracy studies should be prospectively planned cross-sectional studies, done in settings where the test will be used in practice.

  14. From autoantibody research to standardized diagnostic assays in the management of human diseases - report of the 12th Dresden Symposium on Autoantibodies.

    PubMed

    Conrad, K; Andrade, L E C; Chan, E K L; Mahler, M; Meroni, P L; Pruijn, G J M; Steiner, G; Shoenfeld, Y

    2016-07-01

    Testing for autoantibodies (AABs) is becoming more and more relevant, not only for diagnosing autoimmune diseases (AIDs) but also for the differentiation of defined AID subtypes with different clinical manifestations, course and prognosis as well as the very early diagnosis for adequate management in the context of personalized medicine. A major challenge to improve diagnostic accuracy is to harmonize or even standardize AAB analyses. This review presents the results of the 12th Dresden Symposium on Autoantibodies that focused on several aspects of improving autoimmune diagnostics. Topics that are addressed include the International Consensus on ANA Patterns (ICAP) and the International Autoantibody Standardization (IAS) initiatives, the optimization of diagnostic algorithms, the description and evaluation of novel disease-specific AABs as well as the development and introduction of novel assays into routine diagnostics. This review also highlights important developments of recent years, most notably the improvement in diagnosing and predicting the course of rheumatoid arthritis, systemic sclerosis, idiopathic inflammatory myopathies, and of autoimmune neurological, gastrointestinal and liver diseases; the potential diagnostic role of anti-DFS70 antibodies and tumor-associated AABs. Furthermore, some hot topics in autoimmunity regarding disease pathogenesis and management are described. © The Author(s) 2016.

  15. Accuracy-based proficiency testing for testosterone measurements with immunoassays and liquid chromatography-mass spectrometry.

    PubMed

    Cao, Zhimin Tim; Botelho, Julianne Cook; Rej, Robert; Vesper, Hubert

    2017-06-01

    Accurate testosterone measurements are needed to correctly diagnose and treat patients. Proficiency Testing (PT) programs using modified specimens for testing can be limited because of matrix effects and usage of non-reference measurement procedure (RMP)-defined targets for evaluation. Accuracy-based PT can overcome such limitations; however, there is a lack of information on accuracy-based PT and feasibility of its implementation in evaluation for testosterone measurements. Unaltered, single-donor human serum from 2 male and 2 female adult donors were analyzed for testosterone by 142 NYSDH-certified clinical laboratories using 16 immunoassays and LC-MS/MS methods. Testosterone target values were determined using an RMP. The testosterone target concentrations for the 4 specimens were 15.5, 30.0, 402 and 498ng/dl. The biases ranged from -17.8% to 73.1%, 3.1% to 21.3%, -24.8% to 8.6%, and -22.1% to 6.8% for the 4 specimens, respectively. Using a total error target of ±25.1%, which was calculated using the minimum allowable bias and imprecision, 73% of participating laboratories had ≥3 of the 4 results within these limits. The variability in total testosterone measurements can affect clinical decisions. Accuracy-based PT can significantly contribute to improving testosterone testing by providing reliable data on accuracy in patient care to laboratories, assay manufacturers, and standardization programs. Copyright © 2017. Published by Elsevier B.V.

  16. The diagnostic accuracy of three rapid diagnostic tests for typhoid fever at Chittagong Medical College Hospital, Chittagong, Bangladesh.

    PubMed

    Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M

    2015-10-01

    To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  17. Performance evaluation of the Aptima® HCV Quant Dx assay for hepatitis C virus (HCV) RNA detection and quantification in comparison to the Abbott RealTime HCV assay.

    PubMed

    Garbuglia, Anna Rosa; Bibbò, Angela; Sciamanna, Roberta; Pisciotta, Marina; Capobianchi, Maria Rosaria

    2017-07-01

    The Aptima HCV Quant Dx assay (Aptima) is a real-time transcription-mediated amplification assay CE-approved for the diagnosis and monitoring of hepatitis C virus (HCV) infection. Aptima's analytical performance was compared to the Abbott RealTime HCV assay (RealTime) in a clinical routine setting. Overall 295 clinical plasma samples (117 prospective/fresh; 178 retrospective/frozen) from HCV-infected patients were tested in Aptima and RealTime to determine concordance on qualitative and quantitative results. Linearity and precision at low viral loads (VLs; 0.8-3.3LogIU/mL) was tested using dilutions of the 5th WHO standard, in 10 and 20 replicates in the two assays, respectively. The ability to measure different HCV genotypes and accuracy were analyzed using the Seracare EQA panel. Inter-assay agreement for qualitative results (prospective samples) was 88% (kappa=0.78). For the 127 samples with quantitative results in both assays, Aptima yielded on average slightly higher values (by 0.24LogIU/mL; Bland-Altman method) than RealTime. Concordance between assay results was excellent (R=0.98). At low VLs (0.8-3.3LogIU/mL), Aptima demonstrated good linearity and precision, similar to RealTime. Aptima detected and accurately quantified all main HCV genotypes. Aptima demonstrated excellent precision, linearity, and accuracy in all genotypes tested. Good concordance was observed between Aptima and RealTime assays in clinical samples. The performance of the Aptima assay, on the fully automated Panther platform, makes it an excellent candidate for the detection and monitoring of HCV RNA in plasma and serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Diagnostic Accuracy of Cerebrospinal Fluid Amyloid-β Isoforms for Early and Differential Dementia Diagnosis.

    PubMed

    Struyfs, Hanne; Van Broeck, Bianca; Timmers, Maarten; Fransen, Erik; Sleegers, Kristel; Van Broeckhoven, Christine; De Deyn, Peter P; Streffer, Johannes R; Mercken, Marc; Engelborghs, Sebastiaan

    2015-01-01

    Overlapping cerebrospinal fluid biomarkers (CSF) levels between Alzheimer's disease (AD) and non-AD patients decrease differential diagnostic accuracy of the AD core CSF biomarkers. Amyloid-β (Aβ) isoforms might improve the AD versus non-AD differential diagnosis. To determine the added diagnostic value of Aβ isoforms, Aβ(1-37), Aβ(1-38), and Aβ(1-40), as compared to the AD CSF biomarkers Aβ(1-42), T-tau, and P-tau(181P). CSF from patients with dementia due to AD (n = 50), non-AD dementias (n = 50), mild cognitive impairment due to AD (n = 50) and non-demented controls (n = 50) was analyzed with a prototype multiplex assay using MSD detection technology. The non-AD group consisted of frontotemporal dementia (FTD; n = 17), dementia with Lewy bodies (DLB; n = 17), and vascular dementia (n = 16). Aβ(1-37) and Aβ(1-38) increased accuracy to differentiate AD from FTD or DLB. Aβ(1-37), Aβ(1-38), and Aβ(1-40) levels correlated with Mini-Mental State Examination scores and disease duration in dementia due to AD. The Aβ(1-42)/Aβ(1-40) ratio improved diagnostic performance of Aβ(1-42) in most differential diagnostic situations. Aβ(1-42) levels were lower in APOE ε4 carriers compared to non-carriers. Aβ isoforms help to differentiate AD from FTD and DLB. Aβ isoforms increase diagnostic performance of Aβ(1-42). In contrast to Aβ1-42, Aβ isoforms seem to be correlated with disease severity in AD. Adding the Aβ isoforms to the current biomarker panel could enhance diagnostic accuracy.

  19. Method of assaying uranium with prompt fission and thermal neutron borehole logging adjusted by borehole physical characteristics

    DOEpatents

    Barnard, Ralston W.; Jensen, Dal H.

    1982-01-01

    Uranium formations are assayed by prompt fission neutron logging techniques. The uranium in the formation is proportional to the ratio of epithermal counts to thermal or eqithermal dieaway. Various calibration factors enhance the accuracy of the measurement.

  20. Validation of clinical testing for warfarin sensitivity: comparison of CYP2C9-VKORC1 genotyping assays and warfarin-dosing algorithms.

    PubMed

    Langley, Michael R; Booker, Jessica K; Evans, James P; McLeod, Howard L; Weck, Karen E

    2009-05-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 -1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses.

  1. Performance of seven serological assays for diagnosing tularemia

    PubMed Central

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  2. Prediction of skin sensitization potency using machine learning approaches.

    PubMed

    Zang, Qingda; Paris, Michael; Lehmann, David M; Bell, Shannon; Kleinstreuer, Nicole; Allen, David; Matheson, Joanna; Jacobs, Abigail; Casey, Warren; Strickland, Judy

    2017-07-01

    The replacement of animal use in testing for regulatory classification of skin sensitizers is a priority for US federal agencies that use data from such testing. Machine learning models that classify substances as sensitizers or non-sensitizers without using animal data have been developed and evaluated. Because some regulatory agencies require that sensitizers be further classified into potency categories, we developed statistical models to predict skin sensitization potency for murine local lymph node assay (LLNA) and human outcomes. Input variables for our models included six physicochemical properties and data from three non-animal test methods: direct peptide reactivity assay; human cell line activation test; and KeratinoSens™ assay. Models were built to predict three potency categories using four machine learning approaches and were validated using external test sets and leave-one-out cross-validation. A one-tiered strategy modeled all three categories of response together while a two-tiered strategy modeled sensitizer/non-sensitizer responses and then classified the sensitizers as strong or weak sensitizers. The two-tiered model using the support vector machine with all assay and physicochemical data inputs provided the best performance, yielding accuracy of 88% for prediction of LLNA outcomes (120 substances) and 81% for prediction of human test outcomes (87 substances). The best one-tiered model predicted LLNA outcomes with 78% accuracy and human outcomes with 75% accuracy. By comparison, the LLNA predicts human potency categories with 69% accuracy (60 of 87 substances correctly categorized). These results suggest that computational models using non-animal methods may provide valuable information for assessing skin sensitization potency. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes.

    PubMed

    Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J

    2015-04-22

    Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.

  4. Method of assaying uranium with prompt fission and thermal neutron borehole logging adjusted by borehole physical characteristics. [Patient application

    DOEpatents

    Barnard, R.W.; Jensen, D.H.

    1980-11-05

    Uranium formations are assayed by prompt fission neutron logging techniques. The uranium in the formation is proportional to the ratio of epithermal counts to thermal or epithermal dieaway. Various calibration factors enhance the accuracy of the measurement.

  5. Multi-targeted priming for genome-wide gene expression assays.

    PubMed

    Adomas, Aleksandra B; Lopez-Giraldez, Francesc; Clark, Travis A; Wang, Zheng; Townsend, Jeffrey P

    2010-08-17

    Complementary approaches to assaying global gene expression are needed to assess gene expression in regions that are poorly assayed by current methodologies. A key component of nearly all gene expression assays is the reverse transcription of transcribed sequences that has traditionally been performed by priming the poly-A tails on many of the transcribed genes in eukaryotes with oligo-dT, or by priming RNA indiscriminately with random hexamers. We designed an algorithm to find common sequence motifs that were present within most protein-coding genes of Saccharomyces cerevisiae and of Neurospora crassa, but that were not present within their ribosomal RNA or transfer RNA genes. We then experimentally tested whether degenerately priming these motifs with multi-targeted primers improved the accuracy and completeness of transcriptomic assays. We discovered two multi-targeted primers that would prime a preponderance of genes in the genomes of Saccharomyces cerevisiae and Neurospora crassa while avoiding priming ribosomal RNA or transfer RNA. Examining the response of Saccharomyces cerevisiae to nitrogen deficiency and profiling Neurospora crassa early sexual development, we demonstrated that using multi-targeted primers in reverse transcription led to superior performance of microarray profiling and next-generation RNA tag sequencing. Priming with multi-targeted primers in addition to oligo-dT resulted in higher sensitivity, a larger number of well-measured genes and greater power to detect differences in gene expression. Our results provide the most complete and detailed expression profiles of the yeast nitrogen starvation response and N. crassa early sexual development to date. Furthermore, our multi-targeting priming methodology for genome-wide gene expression assays provides selective targeting of multiple sequences and counter-selection against undesirable sequences, facilitating a more complete and precise assay of the transcribed sequences within the genome.

  6. Proactive therapeutic drug monitoring of infliximab: a comparative study of a new point-of-care quantitative test with two established ELISA assays.

    PubMed

    Afonso, J; Lopes, S; Gonçalves, R; Caldeira, P; Lago, P; Tavares de Sousa, H; Ramos, J; Gonçalves, A R; Ministro, P; Rosa, I; Vieira, A I; Dias, C C; Magro, F

    2016-10-01

    Therapeutic drug monitoring is a powerful strategy known to improve the clinical outcomes and to optimise the healthcare resources in the treatment of autoimmune diseases. Currently, most of the methods commercially available for the quantification of infliximab (IFX) are ELISA-based, with a turnaround time of approximately 8 h, and delaying the target dosage adjustment to the following infusion. To validate the first point-of-care IFX quantification device available in the market - the Quantum Blue Infliximab assay (Buhlmann, Schonenbuch, Switzerland) - by comparing it with two well-established methods. The three methods were used to assay the IFX concentration of spiked samples and of the serum of 299 inflammatory bowel diseases (IBD) patients undergoing IFX therapy. The point-of-care assay had an average IFX recovery of 92%, being the most precise among the tested methods. The Intraclass Correlation Coefficients of the point-of-care IFX assay vs. the two ELISA-based established methods were 0.889 and 0.939. Moreover, the accuracy of the point-of-care IFX compared with each of the two reference methods was 77% and 83%, and the kappa statistics revealed a substantial agreement (0.648 and 0.738). The Quantum Blue IFX assay can successfully replace the commonly used ELISA-based IFX quantification kits. This point-of-care IFX assay is able to deliver the results within 15 min makes it ideal for an immediate target concentration adjusted dosing. Moreover, it is a user-friendly desktop device that does not require specific laboratory facilities or highly specialised personnel. © 2016 John Wiley & Sons Ltd.

  7. Multiple Time-of-Flight/Time-of-Flight Events in a Single Laser Shot for Improved Matrix-Assisted Laser Desorption/Ionization Tandem Mass Spectrometry Quantification.

    PubMed

    Prentice, Boone M; Chumbley, Chad W; Hachey, Brian C; Norris, Jeremy L; Caprioli, Richard M

    2016-10-04

    Quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) approaches have historically suffered from poor accuracy and precision mainly due to the nonuniform distribution of matrix and analyte across the target surface, matrix interferences, and ionization suppression. Tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity as well as improve signal-to-noise ratios by eliminating interferences from chemical noise, alleviating some concerns about dynamic range. However, conventional MALDI TOF/TOF modalities typically only scan for a single MS/MS event per laser shot, and multiplex assays require sequential analyses. We describe here new methodology that allows for multiple TOF/TOF fragmentation events to be performed in a single laser shot. This technology allows the reference of analyte intensity to that of the internal standard in each laser shot, even when the analyte and internal standard are quite disparate in m/z, thereby improving quantification while maintaining chemical specificity and duty cycle. In the quantitative analysis of the drug enalapril in pooled human plasma with ramipril as an internal standard, a greater than 4-fold improvement in relative standard deviation (<10%) was observed as well as improved coefficients of determination (R 2 ) and accuracy (>85% quality controls). Using this approach we have also performed simultaneous quantitative analysis of three drugs (promethazine, enalapril, and verapamil) using deuterated analogues of these drugs as internal standards.

  8. Accurate Quantification of Cardiovascular Biomarkers in Serum Using Protein Standard Absolute Quantification (PSAQ™) and Selected Reaction Monitoring*

    PubMed Central

    Huillet, Céline; Adrait, Annie; Lebert, Dorothée; Picard, Guillaume; Trauchessec, Mathieu; Louwagie, Mathilde; Dupuis, Alain; Hittinger, Luc; Ghaleh, Bijan; Le Corvoisier, Philippe; Jaquinod, Michel; Garin, Jérôme; Bruley, Christophe; Brun, Virginie

    2012-01-01

    Development of new biomarkers needs to be significantly accelerated to improve diagnostic, prognostic, and toxicity monitoring as well as therapeutic follow-up. Biomarker evaluation is the main bottleneck in this development process. Selected Reaction Monitoring (SRM) combined with stable isotope dilution has emerged as a promising option to speed this step, particularly because of its multiplexing capacities. However, analytical variabilities because of upstream sample handling or incomplete trypsin digestion still need to be resolved. In 2007, we developed the PSAQ™ method (Protein Standard Absolute Quantification), which uses full-length isotope-labeled protein standards to quantify target proteins. In the present study we used clinically validated cardiovascular biomarkers (LDH-B, CKMB, myoglobin, and troponin I) to demonstrate that the combination of PSAQ and SRM (PSAQ-SRM) allows highly accurate biomarker quantification in serum samples. A multiplex PSAQ-SRM assay was used to quantify these biomarkers in clinical samples from myocardial infarction patients. Good correlation between PSAQ-SRM and ELISA assay results was found and demonstrated the consistency between these analytical approaches. Thus, PSAQ-SRM has the capacity to improve both accuracy and reproducibility in protein analysis. This will be a major contribution to efficient biomarker development strategies. PMID:22080464

  9. Independent data validation of an in vitro method for ...

    EPA Pesticide Factsheets

    In vitro bioaccessibility assays (IVBA) estimate arsenic (As) relative bioavailability (RBA) in contaminated soils to improve the accuracy of site-specific human exposure assessments and risk calculations. For an IVBA assay to gain acceptance for use in risk assessment, it must be shown to reliably predict in vivo RBA that is determined in an established animal model. Previous studies correlating soil As IVBA with RBA have been limited by the use of few soil types as the source of As. Furthermore, the predictive value of As IVBA assays has not been validated using an independent set of As-contaminated soils. Therefore, the current study was undertaken to develop a robust linear model to predict As RBA in mice using an IVBA assay and to independently validate the predictive capability of this assay using a unique set of As-contaminated soils. Thirty-six As-contaminated soils varying in soil type, As contaminant source, and As concentration were included in this study, with 27 soils used for initial model development and nine soils used for independent model validation. The initial model reliably predicted As RBA values in the independent data set, with a mean As RBA prediction error of 5.3% (range 2.4 to 8.4%). Following validation, all 36 soils were used for final model development, resulting in a linear model with the equation: RBA = 0.59 * IVBA + 9.8 and R2 of 0.78. The in vivo-in vitro correlation and independent data validation presented here provide

  10. A sensitive and accurate quantification method for the detection of hepatitis B virus covalently closed circular DNA by the application of a droplet digital polymerase chain reaction amplification system.

    PubMed

    Mu, Di; Yan, Liang; Tang, Hui; Liao, Yong

    2015-10-01

    To develop a sensitive and accurate assay system for the quantification of covalently closed circular HBV DNA (cccDNA) for future clinical monitoring of cccDNA fluctuation during antiviral therapy in the liver of infected patients. A droplet digital PCR (ddPCR)-based assay system detected template DNA input at the single copy level (or ~10(-5) pg of plasmid HBV DNA) by using serially diluted plasmid HBV DNA samples. Compared with the conventional quantitative PCR assay in the detection of cccDNA, which required at least 50 ng of template DNA input, a parallel experiment applying a ddPCR system demonstrates that the lowest detection limit of cccDNA from HepG2.215 cellular DNA samples is around 1 ng, which is equivalent to 0.54 ± 0.94 copies of cccDNA. In addition, we demonstrated that the addition of cccDNA-safe exonuclease and utilization of cccDNA-specific primers in the ddPCR assay system significantly improved the detection accuracy of HBV cccDNA from HepG2.215 cellular DNA samples. The ddPCR-based cccDNA detection system is a sensitive and accurate assay for the quantification of cccDNA in HBV-transfected HepG2.215 cellular DNA samples and may represent an important method for future application in monitoring cccDNA fluctuation during antiviral therapy.

  11. A systematic study on the influencing parameters and improvement of quantitative analysis of multi-component with single marker method using notoginseng as research subject.

    PubMed

    Wang, Chao-Qun; Jia, Xiu-Hong; Zhu, Shu; Komatsu, Katsuko; Wang, Xuan; Cai, Shao-Qing

    2015-03-01

    A new quantitative analysis of multi-component with single marker (QAMS) method for 11 saponins (ginsenosides Rg1, Rb1, Rg2, Rh1, Rf, Re and Rd; notoginsenosides R1, R4, Fa and K) in notoginseng was established, when 6 of these saponins were individually used as internal referring substances to investigate the influences of chemical structure, concentrations of quantitative components, and purities of the standard substances on the accuracy of the QAMS method. The results showed that the concentration of the analyte in sample solution was the major influencing parameter, whereas the other parameters had minimal influence on the accuracy of the QAMS method. A new method for calculating the relative correction factors by linear regression was established (linear regression method), which demonstrated to decrease standard method differences of the QAMS method from 1.20%±0.02% - 23.29%±3.23% to 0.10%±0.09% - 8.84%±2.85% in comparison with the previous method. And the differences between external standard method and the QAMS method using relative correction factors calculated by linear regression method were below 5% in the quantitative determination of Rg1, Re, R1, Rd and Fa in 24 notoginseng samples and Rb1 in 21 notoginseng samples. And the differences were mostly below 10% in the quantitative determination of Rf, Rg2, R4 and N-K (the differences of these 4 constituents bigger because their contents lower) in all the 24 notoginseng samples. The results indicated that the contents assayed by the new QAMS method could be considered as accurate as those assayed by external standard method. In addition, a method for determining applicable concentration ranges of the quantitative components assayed by QAMS method was established for the first time, which could ensure its high accuracy and could be applied to QAMS methods of other TCMs. The present study demonstrated the practicability of the application of the QAMS method for the quantitative analysis of multi-component and the quality control of TCMs and TCM prescriptions. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Microscopic-observation drug susceptibility and thin layer agar assays for the detection of drug resistant tuberculosis: a systematic review and meta-analysis.

    PubMed

    Minion, Jessica; Leung, Erika; Menzies, Dick; Pai, Madhukar

    2010-10-01

    Simple, rapid, and affordable tests are needed to detect drug resistance in Mycobacterium tuberculosis. We did a systematic review and meta-analysis to investigate the accuracy of microscopic-observation drug susceptibility (MODS) and thin layer agar (TLA) assays for rapid screening of patients at risk of drug-resistant tuberculosis. In accordance with protocols and methods recommended by the Cochrane Diagnostic Test Accuracy Working Group, we systematically searched PubMed, Embase, and Biosis for reports published between January, 1990, and February, 2009. We included studies investigating detection of drug resistance in M tuberculosis with the MODS or TLA assay, and in which an accepted reference standard was used. Data extracted from the studies were combined by use of bivariate random-effects regression models and hierarchical summary receiver operating characteristic curves to estimate sensitivity and specificity for detection of resistance to specific drugs. We identified 12 studies, of which nine investigated the MODS assay and three investigated the TLA assay. For the MODS assay of rifampicin resistance, pooled estimates were 98·0% (95% CI 94·5-99·3) for sensitivity and 99·4% (95·7-99·9) for specificity. For the MODS assay of isoniazid resistance with a 0·1 μg/mL cutoff, pooled sensitivity was 97·7% (94·4-99·1) and pooled specificity was 95·8% (88·1-98·6), but with a 0·4 μg/mL cutoff, sensitivity decreased to 90·0% (84·5-93·7) and specificity increased to 98·6% (96·9-99·4). All assessments of rifampicin and isoniazid resistance with the TLA assay yielded 100% accuracy. Mean turnaround time was 9·9 days (95% CI 4·1-15·8) for the MODS assay and 11·1 days (10·1-12·0) for the TLA assay. MODS and TLA assays are inexpensive, rapid alternatives to conventional methods for drug susceptibility testing of M tuberculosis. Our data and expert opinion informed WHO's recommendation for use of selected non-commercial drug susceptibility tests, including MODS, as an interim solution until capacity for genotypic or automated liquid culture drug susceptibility testing is developed. Stop TB Department of WHO. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Against the proposition: for the diagnosis of viral infections, commercial assays provide more reliable results than do in-house assays.

    PubMed

    James, Vivienne

    2008-01-01

    There are no differences inherent in the design of commercial or in-house assays and their early development is similar. The same principles apply and it is on the same criteria of accuracy, reproducibility and clinical relevance of results that all assays are judged. However, if there is sufficient uptake of a commercial assay, its strengths and any flaws soon become apparent and it will only be the best commercial assays that remain in the market. For the in-house assays it is through comparability studies and external quality assessment (EQA) schemes that the best can be demonstrated, albeit this information is only accessible initially to the EQA provider and the laboratories using the assays. The EQA results described here support my supposition that, for the diagnosis of viral infections, commercial assays do not provide more reliable results than do in-house assays.

  14. A new indicator cell line established to monitor bovine foamy virus infection.

    PubMed

    Guo, Hong-Yan; Liang, Zhi-Bin; Li, Yue; Tan, Juan; Chen, Qi-Min; Qiao, Wen-Tao

    2011-10-01

    In order to improve the accuracy for quantitating the bovine foamy virus (BFV) in vitro, we developed a baby hamster kidney cell (BHK)-21-derived indicator cell line containing a plasmid that encodes the firefly luciferase driven by the BFV long terminal repeat promoter (LTR, from -7 to 1012). The BFV titer could be determined by detecting the luciferase expression since the viral trans-activator BTas protein activates the promoter activity of the LTR. One clone, designated BFVL, was selected from ten neomycin-resistant clones. BFVL showed a specific and inducible dose- and time-dependent luciferase activity in response to BFV infection. Although the changes in luciferase activity of BFVL peaked at 84 h post infection, it was possible to differentiate infected and uninfected cells at 48 h post infection. A linear relationship was established between the multiplicity of infection (MOI) of BFV and the activated ratio of luciferase expression in BFVL. Moreover, the sensitivity of the BFVL-based assay for detecting infectious BFV was 10,000 times higher than the conventional CPE-based assay at 48 h post infection. These findings suggest that the BFVL-based assay is rapid, easy, sensitive, quantitative and specific for detection of BFV infection.

  15. A New Improved RP-HPLC Method for Assay of Rosuvastatin Calcium in Tablets

    PubMed Central

    Kaila, H. O.; Ambasana, M. A.; Thakkar, R. S.; Saravaia, H. T.; Shah, A. K.

    2010-01-01

    A reliable and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for assay of rosuvastatin calcium in tablets and for determination of content uniformity. An isocratic separation of rosuvastatin calcium was achieved on YMC C8, 150×4.6 mm i.d., 5 μm particle size columns with a flow rate of 1.5 ml/min and using a photodiode array detector to monitor the eluate at 242 nm. The mobile phase consisted of acetonitrile: water (40:60, v/v) pH 3.5 adjusted with phosphoric acid. The drug was subjected to oxidation, hydrolysis, photolysis and thermal degradation. All degradation products in an overall analytical run time of approximately 10 min with the parent compound rosuvastatin eluting at approximately 5.2 min. Response was a linear function of drug concentration in the range of 0.5-80 μg/ml (r2= 0.9993) with a limit of detection and quantification of 0.1 and 0.5 μg/ml respectively. Accuracy (recovery) was between 99.6 and 101.7%. Degradation products resulting from the stress studies did not interfere with the detection of rosuvastatin and the assay is thus stability-indicating. PMID:21694991

  16. Unlabeled oligonucleotides as internal temperature controls for genotyping by amplicon melting.

    PubMed

    Seipp, Michael T; Durtschi, Jacob D; Liew, Michael A; Williams, Jamie; Damjanovich, Kristy; Pont-Kingdon, Genevieve; Lyon, Elaine; Voelkerding, Karl V; Wittwer, Carl T

    2007-07-01

    Amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, or allele-specific polymerase chain reaction. However, correct differentiation of homozygous mutant and wild-type samples by melting temperature (Tm) requires high-resolution melting and closely controlled reaction conditions. When three different DNA extraction methods were used to isolate DNA from whole blood, amplicon Tm differences of 0.03 to 0.39 degrees C attributable to the extractions were observed. To correct for solution chemistry differences between samples, complementary unlabeled oligonucleotides were included as internal temperature controls to shift and scale the temperature axis of derivative melting plots. This adjustment was applied to a duplex amplicon melting assay for the methylenetetrahydrofolate reductase variants 1298A>C and 677C>T. High- and low-temperature controls bracketing the amplicon melting region decreased the Tm SD within homozygous genotypes by 47 to 82%. The amplicon melting assay was 100% concordant to an adjacent hybridization probe (HybProbe) melting assay when temperature controls were included, whereas a 3% error rate was observed without temperature correction. In conclusion, internal temperature controls increase the accuracy of genotyping by high-resolution amplicon melting and should also improve results on lower resolution instruments.

  17. Biomarker Development for Intraductal Papillary Mucinous Neoplasms Using Multiple Reaction Monitoring Mass Spectrometry.

    PubMed

    Kim, Yikwon; Kang, MeeJoo; Han, Dohyun; Kim, Hyunsoo; Lee, KyoungBun; Kim, Sun-Whe; Kim, Yongkang; Park, Taesung; Jang, Jin-Young; Kim, Youngsoo

    2016-01-04

    Intraductal papillary mucinous neoplasm (IPMN) is a common precursor of pancreatic cancer (PC). Much clinical attention has been directed toward IPMNs due to the increase in the prevalence of PC. The diagnosis of IPMN depends primarily on a radiological examination, but the diagnostic accuracy of this tool is not satisfactory, necessitating the development of accurate diagnostic biomarkers for IPMN to prevent PC. Recently, high-throughput targeted proteomic quantification methods have accelerated the discovery of biomarkers, rendering them powerful platforms for the evolution of IPMN diagnostic biomarkers. In this study, a robust multiple reaction monitoring (MRM) pipeline was applied to discovery and verify IPMN biomarker candidates in a large cohort of plasma samples. Through highly reproducible MRM assays and a stringent statistical analysis, 11 proteins were selected as IPMN marker candidates with high confidence in 184 plasma samples, comprising a training (n = 84) and test set (n = 100). To improve the discriminatory power, we constructed a six-protein panel by combining marker candidates. The multimarker panel had high discriminatory power in distinguishing between IPMN and controls, including other benign diseases. Consequently, the diagnostic accuracy of IPMN can be improved dramatically with this novel plasma-based panel in combination with a radiological examination.

  18. Standardizing a simpler, more sensitive and accurate tail bleeding assay in mice

    PubMed Central

    Liu, Yang; Jennings, Nicole L; Dart, Anthony M; Du, Xiao-Jun

    2012-01-01

    AIM: To optimize the experimental protocols for a simple, sensitive and accurate bleeding assay. METHODS: Bleeding assay was performed in mice by tail tip amputation, immersing the tail in saline at 37 °C, continuously monitoring bleeding patterns and measuring bleeding volume from changes in the body weight. Sensitivity and extent of variation of bleeding time and bleeding volume were compared in mice treated with the P2Y receptor inhibitor prasugrel at various doses or in mice deficient of FcRγ, a signaling protein of the glycoprotein VI receptor. RESULTS: We described details of the bleeding assay with the aim of standardizing this commonly used assay. The bleeding assay detailed here was simple to operate and permitted continuous monitoring of bleeding pattern and detection of re-bleeding. We also reported a simple and accurate way of quantifying bleeding volume from changes in the body weight, which correlated well with chemical assay of hemoglobin levels (r2 = 0.990, P < 0.0001). We determined by tail bleeding assay the dose-effect relation of the anti-platelet drug prasugrel from 0.015 to 5 mg/kg. Our results showed that the correlation of bleeding time and volume was unsatisfactory and that compared with the bleeding time, bleeding volume was more sensitive in detecting a partial inhibition of platelet’s haemostatic activity (P < 0.01). Similarly, in mice with genetic disruption of FcRγ as a signaling molecule of P-selectin glycoprotein ligand-1 leading to platelet dysfunction, both increased bleeding volume and repeated bleeding pattern defined the phenotype of the knockout mice better than that of a prolonged bleeding time. CONCLUSION: Determination of bleeding pattern and bleeding volume, in addition to bleeding time, improved the sensitivity and accuracy of this assay, particularly when platelet function is partially inhibited. PMID:24520531

  19. Efficacy of reducing sugar and phenol-sulfuric acid assays for analysis of soluble carbohydrates in feedstuffs

    USDA-ARS?s Scientific Manuscript database

    Reducing sugar (RSA) and phenol–sulfuric acid (PSA) assays are commonly used to analyze water-soluble carbohydrates. However, questions have arisen as to their accuracy for measurement of feedstuffs with diverse carbohydrate profiles. This study evaluated the efficacy of RSA and PSA as they would co...

  20. Evaluation of multiple reaction monitoring cubed for the analysis of tachykinin related peptides in rat spinal cord using a hybrid triple quadrupole-linear ion trap mass spectrometer.

    PubMed

    Pailleux, Floriane; Beaudry, Francis

    2014-02-01

    Targeted peptide methods generally use HPLC-MS/MRM approaches. Although dependent on the instrumental resolution, interferences may occur while performing analysis of complex biological matrices. HPLC-MS/MRM(3) is a technique, which provides a significantly better selectivity, compared with HPLC-MS/MRM assay. HPLC-MS/MRM(3) allows the detection and quantitation by enriching standard MRM with secondary product ions that are generated within the linear ion trap. Substance P (SP) and neurokinin A (NKA) are tachykinin peptides playing a central role in pain transmission. The objective of this study was to verify whether HPLC-MS/MRM(3) could provide significant advantages over a more traditional HPLC-MS/MRM assay for the quantification of SP and NKA in rat spinal cord. The results suggest that reconstructed MRM(3) chromatograms display significant improvements with the nearly complete elimination of interfering peaks but the sensitivity (i.e. signal-to-noise ratio) was severely reduced. The precision (%CV) observed was between 3.5% and 24.1% using HPLC-MS/MRM and in the range of 4.3-13.1% with HPLC-MS/MRM(3), for SP and NKA. The observed accuracy was within 10% of the theoretical concentrations tested. HPLC-MS/MRM(3) may improve the assay sensitivity to detect difference between samples by reducing significantly the potential of interferences and therefore reduce instrumental errors. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute Scrub Typhus infection.

    PubMed

    Paris, Daniel H; Blacksell, Stuart D; Nawtaisong, Pruksa; Jenjaroen, Kemajittra; Teeraratkul, Achara; Chierakul, Wirongrong; Wuthiekanun, Vanaporn; Kantipong, Pacharee; Day, Nicholas P J

    2011-09-01

    There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.

  2. Clinical effectiveness of a Bayesian algorithm for the diagnosis and management of heparin-induced thrombocytopenia.

    PubMed

    Raschke, R A; Gallo, T; Curry, S C; Whiting, T; Padilla-Jones, A; Warkentin, T E; Puri, A

    2017-08-01

    Essentials We previously published a diagnostic algorithm for heparin-induced thrombocytopenia (HIT). In this study, we validated the algorithm in an independent large healthcare system. The accuracy was 98%, sensitivity 82% and specificity 99%. The algorithm has potential to improve accuracy and efficiency in the diagnosis of HIT. Background Heparin-induced thrombocytopenia (HIT) is a life-threatening drug reaction caused by antiplatelet factor 4/heparin (anti-PF4/H) antibodies. Commercial tests to detect these antibodies have suboptimal operating characteristics. We previously developed a diagnostic algorithm for HIT that incorporated 'four Ts' (4Ts) scoring and a stratified interpretation of an anti-PF4/H enzyme-linked immunosorbent assay (ELISA) and yielded a discriminant accuracy of 0.97 (95% confidence interval [CI], 0.93-1.00). Objectives The purpose of this study was to validate the algorithm in an independent patient population and quantitate effects that algorithm adherence could have on clinical care. Methods A retrospective cohort comprised patients who had undergone anti-PF4/H ELISA and serotonin release assay (SRA) testing in our healthcare system from 2010 to 2014. We determined the algorithm recommendation for each patient, compared recommendations with the clinical care received, and enumerated consequences of discrepancies. Operating characteristics were calculated for algorithm recommendations using SRA as the reference standard. Results Analysis was performed on 181 patients, 10 of whom were ruled in for HIT. The algorithm accurately stratified 98% of patients (95% CI, 95-99%), ruling out HIT in 158, ruling in HIT in 10 and recommending an SRA in 13 patients. Algorithm adherence would have obviated 165 SRAs and prevented 30 courses of unnecessary antithrombotic therapy for HIT. Diagnostic sensitivity was 0.82 (95% CI, 0.48-0.98), specificity 0.99 (95% CI, 0.97-1.00), PPV 0.90 (95% CI, 0.56-0.99) and NPV 0.99 (95% CI, 0.96-1.00). Conclusions An algorithm incorporating 4Ts scoring and a stratified interpretation of the anti-PF4/H ELISA has good operating characteristics and the potential to improve management of suspected HIT patients. © 2017 International Society on Thrombosis and Haemostasis.

  3. Xpert MTB/RIF Assay for Pulmonary Tuberculosis and Rifampicin Resistance in Children: a Meta-Analysis.

    PubMed

    Wang, X W; Pappoe, F; Huang, Y; Cheng, X W; Xu, D F; Wang, H; Xu, Y H

    2015-01-01

    The Xpert MTB/RIF assay has been recommended by WHO to replace conventional microscopy, culture, and drug resistance tests. It simultaneously detects both Mycobacterium tuberculosis infection (TB) and resistance to rifampicin (RIF) within two hours. The objective was to review the available research studies on the accuracy of the Xpert MTB/RIF assay for diagnosing pulmonary TB and RIF-resistance in children. A comprehensive search of Pubmed and Embase was performed up to October 28, 2014. We identified published articles estimating the diagnostic accuracy of the Xpert MTB/RIF assay in children with or without HIV using culture or culture plus clinical TB as standard reference. QUADAS-2 tool was used to evaluate the quality of the studies. A summary estimation for sensitivity, specificity, diagnostic odds ratios (DOR), and the area under the summary ROC curve (AUC) was performed. Meta-analysis was used to establish the overall accuracy. 11 diagnostic studies with 3801 patients were included in the systematic review. The overall analysis revealed a moderate sensitivity and high specificity of 65% (95% CI: 61 - 69%) and 99% (95% CI: 98 - 99%), respectively, and a pooled diagnostic odds ratio of 164.09 (95% CI: 111.89 - 240.64). The AUC value was found to be 0.94. The pooled sensitivity and specificity for paediatric rifampicin resistance were 94.0% (95% CI: 80.0 - 93.0%) and 99.0% (95% CI: 95.0 - 98.0%), respectively. Hence, the Xpert MTB/RIF assay has good diagnostic and rifampicin performance for paediatric pulmonary tuberculosis. The Xpert MTB/RIF is sensitive and specific for diagnosing paediatric pulmonary TB. It is also effective in detecting rifamnicin resistance. It can, therefore, be used as an initial diagnostic tool.

  4. Validation of a method for quantitation of the clopidogrel active metabolite, clopidogrel, clopidogrel carboxylic acid, and 2-oxo-clopidogrel in feline plasma.

    PubMed

    Lyngby, Janne G; Court, Michael H; Lee, Pamela M

    2017-08-01

    The clopidogrel active metabolite (CAM) is unstable and challenging to quantitate. The objective was to validate a new method for stabilization and quantitation of CAM, clopidogrel, and the inactive metabolites clopidogrel carboxylic acid and 2-oxo-clopiodgrel in feline plasma. Two healthy cats administered clopidogrel to demonstrate assay in vivo utility. Stabilization of CAM was achieved by adding 2-bromo-3'methoxyacetophenone to blood tubes to form a derivatized CAM (CAM-D). Method validation included evaluation of calibration curve linearity, accuracy, and precision; within and between assay precision and accuracy; and compound stability using spiked blank feline plasma. Analytes were measured by high performance liquid chromatography with tandem mass spectrometry. In vivo utility was demonstrated by a pharmacokinetic study of cats given a single oral dose of 18.75mg clopidogrel. The 2-oxo-clopidogrel metabolite was unstable. Clopidogrel, CAM-D, and clopidogrel carboxylic acid appear stable for 1 week at room temperature and 9 months at -80°C. Standard curves showed linearity for CAM-D, clopidogrel, and clopidogrel carboxylic acid (r > 0.99). Between assay accuracy and precision was ≤2.6% and ≤7.1% for CAM-D and ≤17.9% and ≤11.3% for clopidogrel and clopidogrel carboxylic acid. Within assay precision for all three compounds was ≤7%. All three compounds were detected in plasma from healthy cats receiving clopidogrel. This methodology is accurate and precise for simultaneous quantitation of CAM-D, clopidogrel, and clopidogrel carboxylic acid in feline plasma but not 2-oxo-clopidogrel. Validation of this assay is the first step to more fully understanding the use of clopidogrel in cats. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. "Center punch" and "whole spot" bioanalysis of apixaban in human dried blood spot samples by UHPLC-MS/MS.

    PubMed

    Zheng, Naiyu; Yuan, Long; Ji, Qin C; Mangus, Heidi; Song, Yan; Frost, Charles; Zeng, Jianing; Aubry, Anne-Françoise; Arnold, Mark E

    2015-04-15

    Apixaban (Eliquis™) was developed by Bristol-Myers Squibb (BMS) and Pfizer to use as an antithrombotic/anticoagulant agent and has been recently approved for the prevention of stroke and systemic embolism in patients with nonvalvular atrial fibrillation. A clinical study of apixaban, sponsored by BMS and Pfizer, included a pilot exploratory portion to evaluate the potential for future drug concentration monitoring using dried blood spot (DBS) sample collection. For DBS sample collection, a fixed blood volume was dispensed onto a DBS card by either regular volumetric pipette (venous blood collection) or capillary dispenser (finger prick blood collection). A 96-well semi-automated liquid-liquid extraction sample preparation procedure was developed to provide clean extracts for UHPLC-MS/MS quantitation. Assays using both partial-spot center punch and whole spot punch were developed and validated. The linear dynamic ranges for all the analyses were from 0.5 to 500 ng/mL. The coefficient of determination (r(2)) values was >0.9944 for all the validation runs. For the center punch approach, the intra-assay precision (%CV) was within 4.4% and inter-assay precision was within 2.6%. The assay accuracy, expressed as %Dev., was within ± 5.4% of the nominal concentrations. One accuracy and precision run was performed using the whole spot approach, the intra-assay precision (%CV) was within 7.1% and the accuracy was within ± 8.0% of the nominal concentrations. In contrast to the center punch approach, the whole spot approach eliminated the effect of hematocrit and high lipids on the analysis of apixaban in human DBS when an accurate sample blood volume was collected on DBS cards. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Development & validation of a quantitative anti-protective antigen IgG enzyme linked immunosorbent assay for serodiagnosis of cutaneous anthrax.

    PubMed

    Ghosh, N; Gunti, D; Lukka, H; Reddy, B R; Padmaja, Jyothi; Goel, A K

    2015-08-01

    Anthrax caused by Bacillus anthracis is primarily a disease of herbivorous animals, although several mammals are vulnerable to it. ELISA is the most widely accepted serodiagnostic assay for large scale surveillance of cutaneous anthrax. The aims of this study were to develop and evaluate a quantitative ELISA for determination of IgG antibodies against B. anthracis protective antigen (PA) in human cutaneous anthrax cases. Quantitative ELISA was developed using the recombinant PA for coating and standard reference serum AVR801 for quantification. A total of 116 human test and control serum samples were used in the study. The assay was evaluated for its precision, accuracy and linearity. The minimum detection limit and lower limit of quantification of the assay for anti-PA IgG were 3.2 and 4 µg/ml, respectively. The serum samples collected from the anthrax infected patients were found to have anti-PA IgG concentrations of 5.2 to 166.3 µg/ml. The intra-assay precision per cent CV within an assay and within an operator ranged from 0.99 to 7.4 per cent and 1.7 to 3.9 per cent, respectively. The accuracy of the assay was high with a per cent error of 6.5 - 24.1 per cent. The described assay was found to be linear between the range of 4 to 80 ng/ml (R [2] = 0.9982; slope = 0.9186; intercept = 0.1108). The results suggested that the developed assay could be a useful tool for quantification of anti-PA IgG response in human after anthrax infection or vaccination.

  7. Use of Cell Viability Assay Data Improves the Prediction Accuracy of Conventional Quantitative Structure–Activity Relationship Models of Animal Carcinogenicity

    PubMed Central

    Zhu, Hao; Rusyn, Ivan; Richard, Ann; Tropsha, Alexander

    2008-01-01

    Background To develop efficient approaches for rapid evaluation of chemical toxicity and human health risk of environmental compounds, the National Toxicology Program (NTP) in collaboration with the National Center for Chemical Genomics has initiated a project on high-throughput screening (HTS) of environmental chemicals. The first HTS results for a set of 1,408 compounds tested for their effects on cell viability in six different cell lines have recently become available via PubChem. Objectives We have explored these data in terms of their utility for predicting adverse health effects of the environmental agents. Methods and results Initially, the classification k nearest neighbor (kNN) quantitative structure–activity relationship (QSAR) modeling method was applied to the HTS data only, for a curated data set of 384 compounds. The resulting models had prediction accuracies for training, test (containing 275 compounds together), and external validation (109 compounds) sets as high as 89%, 71%, and 74%, respectively. We then asked if HTS results could be of value in predicting rodent carcinogenicity. We identified 383 compounds for which data were available from both the Berkeley Carcinogenic Potency Database and NTP–HTS studies. We found that compounds classified by HTS as “actives” in at least one cell line were likely to be rodent carcinogens (sensitivity 77%); however, HTS “inactives” were far less informative (specificity 46%). Using chemical descriptors only, kNN QSAR modeling resulted in 62.3% prediction accuracy for rodent carcinogenicity applied to this data set. Importantly, the prediction accuracy of the model was significantly improved (72.7%) when chemical descriptors were augmented by HTS data, which were regarded as biological descriptors. Conclusions Our studies suggest that combining NTP–HTS profiles with conventional chemical descriptors could considerably improve the predictive power of computational approaches in toxicology. PMID:18414635

  8. A deep learning and novelty detection framework for rapid phenotyping in high-content screening

    PubMed Central

    Sommer, Christoph; Hoefler, Rudolf; Samwer, Matthias; Gerlich, Daniel W.

    2017-01-01

    Supervised machine learning is a powerful and widely used method for analyzing high-content screening data. Despite its accuracy, efficiency, and versatility, supervised machine learning has drawbacks, most notably its dependence on a priori knowledge of expected phenotypes and time-consuming classifier training. We provide a solution to these limitations with CellCognition Explorer, a generic novelty detection and deep learning framework. Application to several large-scale screening data sets on nuclear and mitotic cell morphologies demonstrates that CellCognition Explorer enables discovery of rare phenotypes without user training, which has broad implications for improved assay development in high-content screening. PMID:28954863

  9. Accuracy of direct genomic values in Holstein bulls and cows using subsets of SNP markers

    PubMed Central

    2010-01-01

    Background At the current price, the use of high-density single nucleotide polymorphisms (SNP) genotyping assays in genomic selection of dairy cattle is limited to applications involving elite sires and dams. The objective of this study was to evaluate the use of low-density assays to predict direct genomic value (DGV) on five milk production traits, an overall conformation trait, a survival index, and two profit index traits (APR, ASI). Methods Dense SNP genotypes were available for 42,576 SNP for 2,114 Holstein bulls and 510 cows. A subset of 1,847 bulls born between 1955 and 2004 was used as a training set to fit models with various sets of pre-selected SNP. A group of 297 bulls born between 2001 and 2004 and all cows born between 1992 and 2004 were used to evaluate the accuracy of DGV prediction. Ridge regression (RR) and partial least squares regression (PLSR) were used to derive prediction equations and to rank SNP based on the absolute value of the regression coefficients. Four alternative strategies were applied to select subset of SNP, namely: subsets of the highest ranked SNP for each individual trait, or a single subset of evenly spaced SNP, where SNP were selected based on their rank for ASI, APR or minor allele frequency within intervals of approximately equal length. Results RR and PLSR performed very similarly to predict DGV, with PLSR performing better for low-density assays and RR for higher-density SNP sets. When using all SNP, DGV predictions for production traits, which have a higher heritability, were more accurate (0.52-0.64) than for survival (0.19-0.20), which has a low heritability. The gain in accuracy using subsets that included the highest ranked SNP for each trait was marginal (5-6%) over a common set of evenly spaced SNP when at least 3,000 SNP were used. Subsets containing 3,000 SNP provided more than 90% of the accuracy that could be achieved with a high-density assay for cows, and 80% of the high-density assay for young bulls. Conclusions Accurate genomic evaluation of the broader bull and cow population can be achieved with a single genotyping assays containing ~ 3,000 to 5,000 evenly spaced SNP. PMID:20950478

  10. Probabilistic hazard assessment for skin sensitization potency by dose–response modeling using feature elimination instead of quantitative structure–activity relationships

    PubMed Central

    McKim, James M.; Hartung, Thomas; Kleensang, Andre; Sá-Rocha, Vanessa

    2016-01-01

    Supervised learning methods promise to improve integrated testing strategies (ITS), but must be adjusted to handle high dimensionality and dose–response data. ITS approaches are currently fueled by the increasing mechanistic understanding of adverse outcome pathways (AOP) and the development of tests reflecting these mechanisms. Simple approaches to combine skin sensitization data sets, such as weight of evidence, fail due to problems in information redundancy and high dimension-ality. The problem is further amplified when potency information (dose/response) of hazards would be estimated. Skin sensitization currently serves as the foster child for AOP and ITS development, as legislative pressures combined with a very good mechanistic understanding of contact dermatitis have led to test development and relatively large high-quality data sets. We curated such a data set and combined a recursive variable selection algorithm to evaluate the information available through in silico, in chemico and in vitro assays. Chemical similarity alone could not cluster chemicals’ potency, and in vitro models consistently ranked high in recursive feature elimination. This allows reducing the number of tests included in an ITS. Next, we analyzed with a hidden Markov model that takes advantage of an intrinsic inter-relationship among the local lymph node assay classes, i.e. the monotonous connection between local lymph node assay and dose. The dose-informed random forest/hidden Markov model was superior to the dose-naive random forest model on all data sets. Although balanced accuracy improvement may seem small, this obscures the actual improvement in misclassifications as the dose-informed hidden Markov model strongly reduced "false-negatives" (i.e. extreme sensitizers as non-sensitizer) on all data sets. PMID:26046447

  11. Probabilistic hazard assessment for skin sensitization potency by dose-response modeling using feature elimination instead of quantitative structure-activity relationships.

    PubMed

    Luechtefeld, Thomas; Maertens, Alexandra; McKim, James M; Hartung, Thomas; Kleensang, Andre; Sá-Rocha, Vanessa

    2015-11-01

    Supervised learning methods promise to improve integrated testing strategies (ITS), but must be adjusted to handle high dimensionality and dose-response data. ITS approaches are currently fueled by the increasing mechanistic understanding of adverse outcome pathways (AOP) and the development of tests reflecting these mechanisms. Simple approaches to combine skin sensitization data sets, such as weight of evidence, fail due to problems in information redundancy and high dimensionality. The problem is further amplified when potency information (dose/response) of hazards would be estimated. Skin sensitization currently serves as the foster child for AOP and ITS development, as legislative pressures combined with a very good mechanistic understanding of contact dermatitis have led to test development and relatively large high-quality data sets. We curated such a data set and combined a recursive variable selection algorithm to evaluate the information available through in silico, in chemico and in vitro assays. Chemical similarity alone could not cluster chemicals' potency, and in vitro models consistently ranked high in recursive feature elimination. This allows reducing the number of tests included in an ITS. Next, we analyzed with a hidden Markov model that takes advantage of an intrinsic inter-relationship among the local lymph node assay classes, i.e. the monotonous connection between local lymph node assay and dose. The dose-informed random forest/hidden Markov model was superior to the dose-naive random forest model on all data sets. Although balanced accuracy improvement may seem small, this obscures the actual improvement in misclassifications as the dose-informed hidden Markov model strongly reduced " false-negatives" (i.e. extreme sensitizers as non-sensitizer) on all data sets. Copyright © 2015 John Wiley & Sons, Ltd.

  12. The use of ex vivo human skin tissue for genotoxicity testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reus, Astrid A.; Usta, Mustafa; Krul, Cyrille A.M., E-mail: cyrille.krul@tno.nl

    2012-06-01

    As a result of the chemical legislation concerning the registration, evaluation, authorization and restriction of chemicals (REACH), and the Seventh Amendment to the Cosmetics Directive, which prohibits animal testing in Europe for cosmetics, alternative methods for safety evaluation of chemicals are urgently needed. Current in vitro genotoxicity assays are not sufficiently predictive for the in vivo situation, resulting in an unacceptably high number of misleading positives. For many chemicals and ingredients of personal care products the skin is the first site of contact, but there are no in vitro genotoxicity assays available in the skin for additional evaluation of positivemore » or equivocal responses observed in regulatory in vitro genotoxicity assays. In the present study ex vivo human skin tissue obtained from surgery was used for genotoxicity evaluation of chemicals by using the comet assay. Fresh ex vivo human skin tissue was cultured in an air–liquid interface and topically exposed to 20 chemicals, including true positive, misleading positive and true negative genotoxins. Based on the results obtained in the present study, the sensitivity, specificity and accuracy of the ex vivo skin comet assay to predict in vivo genotoxicity were 89%, 90% and 89%, respectively. Donor and experimental variability were mainly reflected in the magnitude of the response and not the difference between the presence and absence of a genotoxic response. The present study indicates that human skin obtained from surgery is a promising and robust model for safety evaluation of chemicals that are in direct contact with the skin. -- Highlights: ► We use human skin obtained from surgery for genotoxicity evaluation of chemicals. ► We use the comet assay as parameter for genotoxicity in ex vivo human skin. ► Sensitivity, specificity and accuracy to predict in vivo genotoxins are determined. ► Sensitivity, specificity and accuracy are 89%, 90% and 90%, respectively. ► The method is suitable for evaluation of chemicals that are in contact with skin.« less

  13. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    PubMed

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  14. The New Xpert MTB/RIF Ultra: Improving Detection of Mycobacterium tuberculosis and Resistance to Rifampin in an Assay Suitable for Point-of-Care Testing.

    PubMed

    Chakravorty, Soumitesh; Simmons, Ann Marie; Rowneki, Mazhgan; Parmar, Heta; Cao, Yuan; Ryan, Jamie; Banada, Padmapriya P; Deshpande, Srinidhi; Shenai, Shubhada; Gall, Alexander; Glass, Jennifer; Krieswirth, Barry; Schumacher, Samuel G; Nabeta, Pamela; Tukvadze, Nestani; Rodrigues, Camilla; Skrahina, Alena; Tagliani, Elisa; Cirillo, Daniela M; Davidow, Amy; Denkinger, Claudia M; Persing, David; Kwiatkowski, Robert; Jones, Martin; Alland, David

    2017-08-29

    The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. IMPORTANCE The Xpert MTB/RIF assay (Xpert), the first point-of-care assay for tuberculosis (TB), was endorsed by the World Health Organization in December 2010. Since then, 23 million Xpert tests have been procured in 130 countries. Although Xpert showed high overall sensitivity and specificity with pulmonary samples, its sensitivity has been lower with smear-negative pulmonary samples and extrapulmonary samples. In addition, the prediction of rifampin resistance (RIF-R) in paucibacillary samples and for a few rpoB mutations has resulted in both false-positive and false-negative results. The present study is the first demonstration of the design features and operational characteristics of an improved Xpert Ultra assay. This study also shows that the Ultra format overcomes many of the known shortcomings of Xpert. The new assay should significantly improve TB detection, especially in patients with paucibacillary disease, and provide more-reliable detection of RIF-R. Copyright © 2017 Chakravorty et al.

  15. Optimization and Validation of the TZM-bl Assay for Standardized Assessments of Neutralizing Antibodies Against HIV-1

    PubMed Central

    Sarzotti-Kelsoe, Marcella; Bailer, Robert T; Turk, Ellen; Lin, Chen-li; Bilska, Miroslawa; Greene, Kelli M.; Gao, Hongmei; Todd, Christopher A.; Ozaki, Daniel A.; Seaman, Michael S.; Mascola, John R.; Montefiori, David C.

    2014-01-01

    The TZM-bl assay measures antibody-mediated neutralization of HIV-1 as a function of reductions in HIV-1 Tat-regulated firefly luciferase (Luc) reporter gene expression after a single round of infection with Env-pseudotyped viruses. This assay has become the main endpoint neutralization assay used for the assessment of preclinical and clinical trial samples by a growing number of laboratories worldwide. Here we present the results of the formal optimization and validation of the TZM-bl assay, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. The assay was evaluated for specificity, accuracy, precision, limits of detection and quantitation, linearity, range and robustness. The validated manual TZM-bl assay was also adapted, optimized and qualified to an automated 384-well format. PMID:24291345

  16. The accuracy of serum galactomannan assay in diagnosing invasive pulmonary aspergillosis.

    PubMed

    Sarrafzadeh, Shokooh Azam; Hoseinpoor Rafati, Ali; Ardalan, Maryam; Mansouri, Davood; Tabarsi, Payam; Pourpak, Zahra

    2010-09-01

    Galactomannan (GM) antigen is an aspergillus specific antigen that is released during the growth phase of invasive aspergillosis. We aimed to find the optimum cutoff and accuracy of serum Galactomannan assay in immunocompromised patients. Immunocompromised patients diagnosed with invasive pulmonary aspergillosis (IPA) based on the European Organization for Research and Treatment of Cancer/Invasive Mycosis Study Group (EORTC/MSG) with three levels of certainty proven, probable and possible, referred for GM antigen measurement at Immunology, Asthma and Allergy Research Institute (IAARI) from 2006 to 2009 and if they met the criteria were enrolled in this study. Totally 49 patients with IPA were enrolled in our study. According to EORTC/MSG, patients categorized into three levels of certainty: They were diagnosed as 'proven' invasive pulmonary aspergillosis 16(32.7%), 'probable' 18(36.7%) and 'possible' 15(30.6%). The most common host risk factor was solid tumors 17(34.7%). The accuracy of Galactomannan assay increased from 0.5 to 2 cutoffs. The optimum sensitivity and specificity obtained at the index cutoff of ≥1.5 for diagnosis of "proven" IPA; which were respectively, 69.2% and 72.2%. Other cutoffs had high variance between sensitivity and specificity for diagnosis of IPA. The calculated cutoff gained by receiver operating characteristic (ROC) analysis for detecting proven IPA was 1.5. Intermediate accuracy of serum GM test in conjunct with clinical findings would help early IPA detection among immunocompromised patients.

  17. Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer.

    PubMed

    Wadhwa, Ashutosh; Johonson, Rachel E; Eda, Keiko; Waters, W Ray; Palmer, Mitchell V; Bannantine, John P; Eda, Shigetoshi

    2014-07-04

    The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed by using ethanol extract of Mycobacterium bovis (M. bovis). The assay, named (ethanol vortex ELISA [EVELISA]), was evaluated for detection of anti- M. bovis antibodies in the sera of cattle and white-tailed deer. By using the EVELISA, we tested sera obtained from two species of animals; cattle (n = 62 [uninfected, n = 40; naturally infected, n = 22]) and white-tailed deer (n = 41 [uninfected, n = 25; naturally infected, n = 7; experimentally infected, n = 9]). To detect species specific molecules, components in the ethanol extract were analyzed by thin layer chromatography and western blotting. Among the tested animals, 77.2% of infected cattle and 87.5% of infected deer tested positive for anti- M. bovis antibody. There were only minor false positive reactions (7.5% in cattle and 0% in deer) in uninfected animals. M. bovis -specific lipids and protein (MPB83) in the ethanol extract were detected by thin layer chromatography and western blotting, respectively. The results warrant further evaluation and validation of EVELISA for bovine TB diagnosis of traditional and alternative livestock as well as for free-ranging animal species.

  18. Development of an ELISA microarray assay for the sensitive and simultaneous detection of ten biodefense toxins.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenko, Kathryn; Zhang, Yanfeng; Kostenko, Yulia

    Plant and microbial toxins are considered bioterrorism threat agents because of their extreme toxicity and/or ease of availability. Additionally, some of these toxins are increasingly responsible for accidental food poisonings. The current study utilized an ELISA-based protein antibody microarray for the multiplexed detection of ten biothreat toxins, botulinum neurotoxins (BoNT) A, B, C, D, E, F, ricin, shiga toxins 1 and 2 (Stx), and staphylococcus enterotoxin B (SEB), in buffer and complex biological matrices. The multiplexed assay displayed a sensitivity of 1.3 pg/mL (BoNT/A, BoNT/B, SEB, Stx-1 and Stx-2), 3.3 pg/mL (BoNT/C, BoNT/E, BoNT/F) and 8.2 pg/mL (BoNT/D, ricin). Allmore » assays demonstrated high accuracy (75-120 percent recovery) and reproducibility (most coefficients of variation < 20%). Quantification curves for the ten toxins were also evaluated in clinical samples (serum, plasma, nasal fluid, saliva, stool, and urine) and environmental samples (apple juice, milk and baby food) with overall minimal matrix effects. The multiplex assays were highly specific, with little crossreactivity observed between the selected toxin antibodies. The results demonstrate a multiplex microarray that improves current immunoassay sensitivity for biological warfare agents in buffer, clinical, and environmental samples.« less

  19. Advance in plasma SEPT9 gene methylation assay for colorectal cancer early detection

    PubMed Central

    Wang, Yu; Chen, Pei-Min; Liu, Rong-Bin

    2018-01-01

    This review article summarizes the research advances of the plasma-based SEPT9 gene methylation assay for the clinical detection of colorectal cancer and its limitations. Colorectal cancer is a common malignancy with a poor prognosis and a high mortality, for which early detection and diagnosis are particularly crucial for the high-risk groups. Increasing evidence supported that SEPT9 gene methylation is associated with the pathogenesis of colorectal cancer and that detecting the level of methylation of SEPT9 in the peripheral blood can be used for screening of colorectal cancer in susceptible populations. In recent years, the data obtained in clinical studies demonstrated that the SEPT9 gene methylation assay has a good diagnostic performance with regard to both sensitivity and specificity with the advantage of better acceptability, convenience and compliance with serological testing compared with fecal occult blood tests and carcinoembryonic antigen for colorectal cancer (CRC). Furthermore, the combination of multiple methods or markers has become a growing trend for CRC detection and screening. Nevertheless, the clinical availability of the methylated SEPT9 assay is still limited because of the large degree of sample heterogeneity caused by demographic characteristics, pathological features, comorbidities and/or technique selection. Another factor is the cost-effectiveness of colorectal cancer screening strategies that hinders its large-scale application. In addition, improvements in its accuracy in detecting adenomas and premalignant polyps are required. PMID:29375744

  20. Advance in plasma SEPT9 gene methylation assay for colorectal cancer early detection.

    PubMed

    Wang, Yu; Chen, Pei-Min; Liu, Rong-Bin

    2018-01-15

    This review article summarizes the research advances of the plasma-based SEPT9 gene methylation assay for the clinical detection of colorectal cancer and its limitations. Colorectal cancer is a common malignancy with a poor prognosis and a high mortality, for which early detection and diagnosis are particularly crucial for the high-risk groups. Increasing evidence supported that SEPT9 gene methylation is associated with the pathogenesis of colorectal cancer and that detecting the level of methylation of SEPT9 in the peripheral blood can be used for screening of colorectal cancer in susceptible populations. In recent years, the data obtained in clinical studies demonstrated that the SEPT9 gene methylation assay has a good diagnostic performance with regard to both sensitivity and specificity with the advantage of better acceptability, convenience and compliance with serological testing compared with fecal occult blood tests and carcinoembryonic antigen for colorectal cancer (CRC). Furthermore, the combination of multiple methods or markers has become a growing trend for CRC detection and screening. Nevertheless, the clinical availability of the methylated SEPT9 assay is still limited because of the large degree of sample heterogeneity caused by demographic characteristics, pathological features, comorbidities and/or technique selection. Another factor is the cost-effectiveness of colorectal cancer screening strategies that hinders its large-scale application. In addition, improvements in its accuracy in detecting adenomas and premalignant polyps are required.

  1. A practical method for extending the biuret assay to protein determination of corn-based products.

    PubMed

    Liu, Zelong; Pan, Junhui

    2017-06-01

    A modified biuret method suitable for protein determination of corn-based products was developed by introducing a combination of an alkaline reagent with sodium dodecyl sulfate (reagent A) and heat treatments. The method was tested on seven corn-based samples. The results showed mostly good agreement (P>0.05) as compared to the Kjeldahl values. The proposed method was found to enhance the accuracy of prediction on zein content using bovine serum albumin as standard. Reagent A and sample treatment were proved to effectively improve protein solubilization for the thermally-dried corn-based products, e.g. corn gluten meal. The absorbance was stable for at least 1-h. Moreover, the whole measurement of protein content only needs 15-20min more than the traditional biuret assay, and can be performed in batches. The findings suggest that the proposed method could be a timesaving alternative for routine protein analyses in corn processing factories. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Immunodiagnosis of Canine Visceral Leishmaniasis Using Mimotope Peptides Selected from Phage Displayed Combinatorial Libraries

    PubMed Central

    Toledo-Machado, Christina Monerat; Machado de Avila, Ricardo Andrez; NGuyen, Christophe; Granier, Claude; Bueno, Lilian Lacerda; Carneiro, Claudia Martins; Menezes-Souza, Daniel; Carneiro, Rubens Antonio; Chávez-Olórtegui, Carlos; Fujiwara, Ricardo Toshio

    2015-01-01

    ELISA and RIFI are currently used for serodiagnosis of canine visceral leishmaniasis (CVL). The accuracy of these tests is controversial in endemic areas where canine infections by Trypanosoma cruzi may occur. We evaluated the usefulness of synthetic peptides that were selected through phage display technique in the serodiagnosis of CVL. Peptides were chosen based on their ability to bind to IgGs purified from infected dogs pooled sera. We selected three phage clones that reacted only with those IgGs. Peptides were synthesized, polymerized with glutaraldehyde, and used as antigens in ELISA assays. Each individual peptide or a mix of them was reactive with infected dogs serum. The assay was highly sensitive and specific when compared to soluble Leishmania antigen that showed cross-reactivity with anti-T. cruzi IgGs. Our results demonstrate that phage display technique is useful for selection of peptides that may represent valuable synthetic antigens for an improved serodiagnosis of CVL. PMID:25710003

  3. Piezo- and solenoid valve-based liquid dispensing for miniaturized assays.

    PubMed

    Niles, Walter D; Coassin, Peter J

    2005-04-01

    Miniaturization of biological assays requires dispensing liquids in the submicroliter range of volumes. Accuracy and reproducibility of dispensing this range depend on both the dispenser and the receptacle in which the assay is constructed. Miniaturization technologies developed by Aurora Discovery, Inc. (San Diego, CA) include high-density multiwell plates for assay samples and reagent storage, as well as piezo-based and solenoid valve-based liquid dispensers. Some basic principles of small-volume dispensing by jetting are described to provide context for dispenser design and function. Performance of the latest instruments incorporating these dispensing devices is presented.

  4. Validated low-volume aldosterone immunoassay tailored to GCLP-compliant investigations in small sample volumes.

    PubMed

    Schaefer, J; Burckhardt, B B; Tins, J; Bartel, A; Laeer, S

    2017-12-01

    Heart failure is well investigated in adults, but data in children is lacking. To overcome this shortage of reliable data, appropriate bioanalytical assays are required. Development and validation of a bioanalytical assay for the determination of aldosterone concentrations in small sample volumes applicable to clinical studies under Good Clinical Laboratory Practice. An immunoassay was developed based on a commercially available enzyme-linked immunosorbent assay and validated according to current bioanalytical guidelines of the EMA and FDA. The assay (range 31.3-1000 pg/mL [86.9-2775 pmol/L]) is characterized by a between-run accuracy from - 3.8% to - 0.8% and a between-run imprecision ranging from 4.9% to 8.9% (coefficient of variation). For within-run accuracy, the relative error was between - 11.1% and + 9.0%, while within-run imprecision ranged from 1.2% to 11.8% (CV). For parallelism and dilutional linearity, the relative error of back-calculated concentrations varied from - 14.1% to + 8.4% and from - 7.4% to + 10.5%, respectively. The immunoassay is compliant with the bioanalytical guidelines of the EMA and FDA and allows accurate and precise aldosterone determinations. As the assay can run low-volume samples, it is especially valuable for pediatric investigations.

  5. Screening Chemicals for Estrogen Receptor Bioactivity Using a Computational Model.

    PubMed

    Browne, Patience; Judson, Richard S; Casey, Warren M; Kleinstreuer, Nicole C; Thomas, Russell S

    2015-07-21

    The U.S. Environmental Protection Agency (EPA) is considering high-throughput and computational methods to evaluate the endocrine bioactivity of environmental chemicals. Here we describe a multistep, performance-based validation of new methods and demonstrate that these new tools are sufficiently robust to be used in the Endocrine Disruptor Screening Program (EDSP). Results from 18 estrogen receptor (ER) ToxCast high-throughput screening assays were integrated into a computational model that can discriminate bioactivity from assay-specific interference and cytotoxicity. Model scores range from 0 (no activity) to 1 (bioactivity of 17β-estradiol). ToxCast ER model performance was evaluated for reference chemicals, as well as results of EDSP Tier 1 screening assays in current practice. The ToxCast ER model accuracy was 86% to 93% when compared to reference chemicals and predicted results of EDSP Tier 1 guideline and other uterotrophic studies with 84% to 100% accuracy. The performance of high-throughput assays and ToxCast ER model predictions demonstrates that these methods correctly identify active and inactive reference chemicals, provide a measure of relative ER bioactivity, and rapidly identify chemicals with potential endocrine bioactivities for additional screening and testing. EPA is accepting ToxCast ER model data for 1812 chemicals as alternatives for EDSP Tier 1 ER binding, ER transactivation, and uterotrophic assays.

  6. Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays

    PubMed Central

    Afonso, Joana; Lopes, Susana; Gonçalves, Raquel; Caldeira, Paulo; Lago, Paula; Tavares de Sousa, Helena; Ramos, Jaime; Gonçalves, Ana Rita; Ministro, Paula; Rosa, Isadora; Vieira, Ana Isabel; Coelho, Rosa; Tavares, Patrícia; Soares, João; Sousa, Ana Lúcia; Carvalho, Diana; Sousa, Paula; da Silva, João Pereira; Meira, Tânia; Silva Ferreira, Filipa; Dias, Cláudia Camila; Chowers, Yehuda; Ben-Horin, Shomron; Magro, Fernando

    2016-01-01

    Background: There is scant information on the accuracy of different assays used to measure anti-infliximab antibodies (ADAs), especially in the presence of detectable infliximab (IFX). We thus aimed to evaluate and compare three different assays for the detection of IFX and ADAs and to clarify the impact of the presence of circulating IFX on the accuracy of the ADA assays. Methods: Blood samples from 79 ulcerative colitis (UC) patients treated with infliximab were assessed for IFX levels and ADAs using three different assays: an in-house assay and two commercial kits, Immundiagnostik and Theradiag. Sera samples with ADAs and undetectable levels of IFX were spiked with exogenous IFX and analyzed for ADAs. Results: The three assays showed 81–96% agreement for the measured IFX level. However, the in-house assay and Immundiagnostik assays detected ADAs in 34 out of 79 samples, whereas Theradiag only detected ADAs in 24 samples. Samples negative for ADAs with Theradiag, but ADA-positive in both the in-house and Immundiagnostik assays, were positive for IFX or IgG4 ADAs. In spiking experiments, a low concentration of exogenous IFX (5 µg/ml) hampered ADA detection with Theradiag in sera samples with ADA levels of between 3 and 10 µg/ml. In the Immundiagnostik assay detection interference was only observed at concentrations of exogenous IFX higher than 30 µg/ml. However, in samples with high levels of ADAs (>25 µg/ml) interference was only observed at IFX concentrations higher than 100 µg/ml in all three assays. Binary (IFX/ADA) stratification of the results showed that IFX+/ADA- and IFX-/ADAs+ were less influenced by the assay results than the double-positive (IFX+/ADAs+) and double-negative (IFX-/ADAs-) combination. Conclusions: All three methodologies are equally suitable for measuring IFX levels. However, erroneous therapeutic decisions may occur when patients show double-negative (IFX-/ADAs-) or double-positive (IFX+/ADAs+) status, since agreement between assays is significantly lower in these circumstances. PMID:27803733

  7. Lead discovery for mammalian elongation of long chain fatty acids family 6 using a combination of high-throughput fluorescent-based assay and RapidFire mass spectrometry assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takamiya, Mari; Discovery Technology Laboratories, Sohyaku, Innovative Research Division, Mitsubishi Tanabe Pharma Corporation, Kawagishi, Toda-shi, Saitama; Sakurai, Masaaki

    A high-throughput RapidFire mass spectrometry assay is described for elongation of very long-chain fatty acids family 6 (Elovl6). Elovl6 is a microsomal enzyme that regulates the elongation of C12-16 saturated and monounsaturated fatty acids. Elovl6 may be a new therapeutic target for fat metabolism disorders such as obesity, type 2 diabetes, and nonalcoholic steatohepatitis. To identify new Elovl6 inhibitors, we developed a high-throughput fluorescence screening assay in 1536-well format. However, a number of false positives caused by fluorescent interference have been identified. To pick up the real active compounds among the primary hits from the fluorescence assay, we developed amore » RapidFire mass spectrometry assay and a conventional radioisotope assay. These assays have the advantage of detecting the main products directly without using fluorescent-labeled substrates. As a result, 276 compounds (30%) of the primary hits (921 compounds) in a fluorescence ultra-high-throughput screening method were identified as common active compounds in these two assays. It is concluded that both methods are very effective to eliminate false positives. Compared with the radioisotope method using an expensive {sup 14}C-labeled substrate, the RapidFire mass spectrometry method using unlabeled substrates is a high-accuracy, high-throughput method. In addition, some of the hit compounds selected from the screening inhibited cellular fatty acid elongation in HEK293 cells expressing Elovl6 transiently. This result suggests that these compounds may be promising lead candidates for therapeutic drugs. Ultra-high-throughput fluorescence screening followed by a RapidFire mass spectrometry assay was a suitable strategy for lead discovery against Elovl6. - Highlights: • A novel assay for elongation of very-long-chain fatty acids 6 (Elovl6) is proposed. • RapidFire mass spectrometry (RF-MS) assay is useful to select real screening hits. • RF-MS assay is proved to be beneficial because of its high-throughput and accuracy. • A combination of fluorescent and RF-MS assays is effective for Elovl6 inhibitors.« less

  8. Comparison of five commercial anti-tetanus toxoid immunoglobulin G enzyme-linked immunosorbent assays.

    PubMed

    Perry, A L; Hayes, A J; Cox, H A; Alcock, F; Parker, A R

    2009-12-01

    Five commercially available enzyme-linked immunosorbent assays for the measurement of anti-tetanus toxoid immunoglobulin G (IgG) antibodies were evaluated for performance. The data suggest that there are manufacturer-dependent differences in sensitivity and accuracy for the determination of tetanus toxoid IgG antibodies that could result in different diagnostic interpretations.

  9. Simple Method for Assaying Colistin Methanesulfonate in Plasma and Urine Using High-Performance Liquid Chromatography

    PubMed Central

    Li, Jian; Milne, Robert W.; Nation, Roger L.; Turnidge, John D.; Coulthard, Kingsley; Valentine, Jason

    2002-01-01

    A simple and sensitive high-performance liquid chromatographic method is described for the determination of colistimethate sodium in plasma and urine. The accuracy and reproducibility was within 10.1 and 11.2% with rat plasma and urine, respectively. Several commonly coadministered antibacterial agents do not interfere with the assay. PMID:12234867

  10. Qualification of a select one-stage activated partial thromboplastin time-based clotting assay and two chromogenic assays for the post-administration monitoring of nonacog beta pegol.

    PubMed

    Tiefenbacher, S; Bohra, R; Amiral, J; Bowyer, A; Kitchen, S; Lochu, A; Rosén, S; Ezban, M

    2017-10-01

    Essentials Nonacog beta pegol (N9-GP) is an extended half-life, recombinant human factor IX (FIX). One-stage clotting (OSC) and chromogenic FIX activity assays were assessed for N9-GP recovery. OSC STA ® -Cephascreen ® , ROX FIX and BIOPHEN FIX chromogenic assays were qualified for N9-GP. Other extended half-life factor products should be assessed in a similar way prior to approval. Background Nonacog beta pegol (N9-GP) is an extended half-life, glycoPEGylated recombinant human factor IX that is under development for the prophylaxis and treatment of bleeding episodes in hemophilia B patients. Considerable reagent-dependent variability has been observed when one-stage clotting assays are used to measure the recovery of recombinant FIX products, including N9-GP. Objective To qualify select one-stage clotting and chromogenic FIX activity assays for measuring N9-GP recovery. Methods The accuracy and precision of the one-stage clotting assay (with the STA-Cephascreen activated partial thromboplastin [APTT] reagent) and the ROX Factor IX and BIOPHEN Factor IX chromogenic assays for measuring N9-GP recovery were assessed in N9-GP-spiked hemophilia B plasma samples in a systematic manner at three independent sites, with manufacturer-recommended protocols and/or site-specific assay setups, including different instruments. Results For each of the three FIX activity assays qualified on five different reagent-instrument systems, acceptable intra-assay and interassay accuracy and precision, dilution integrity, reagent robustness and freeze-thaw and short-term sample stabilities were demonstrated. The STA-Cephascreen assay showed a limited reportable range at one of the three qualification sites, and the BIOPHEN Factor IX assay showed suspect low-end sensitivity at one of the three qualification sites. An individual laboratory would account for these limitations by adjusting the assay's reportable range; thus, these findings are not considered to impact the respective assay qualifications. Conclusion The one-stage clotting assay with the STA-Cephascreen APTT reagent, the ROX Factor IX chromogenic assay and the BIOPHEN Factor IX chromogenic assay are considered to be qualified for the measurement of N9-GP in 3.2% (0.109 m) citrated human plasma. © 2017 International Society on Thrombosis and Haemostasis.

  11. Going Vertical To Improve the Accuracy of Atomic Force Microscopy Based Single-Molecule Force Spectroscopy.

    PubMed

    Walder, Robert; Van Patten, William J; Adhikari, Ayush; Perkins, Thomas T

    2018-01-23

    Single-molecule force spectroscopy (SMFS) is a powerful technique to characterize the energy landscape of individual proteins, the mechanical properties of nucleic acids, and the strength of receptor-ligand interactions. Atomic force microscopy (AFM)-based SMFS benefits from ongoing progress in improving the precision and stability of cantilevers and the AFM itself. Underappreciated is that the accuracy of such AFM studies remains hindered by inadvertently stretching molecules at an angle while measuring only the vertical component of the force and extension, degrading both measurements. This inaccuracy is particularly problematic in AFM studies using double-stranded DNA and RNA due to their large persistence length (p ≈ 50 nm), often limiting such studies to other SMFS platforms (e.g., custom-built optical and magnetic tweezers). Here, we developed an automated algorithm that aligns the AFM tip above the DNA's attachment point to a coverslip. Importantly, this algorithm was performed at low force (10-20 pN) and relatively fast (15-25 s), preserving the connection between the tip and the target molecule. Our data revealed large uncorrected lateral offsets for 100 and 650 nm DNA molecules [24 ± 18 nm (mean ± standard deviation) and 180 ± 110 nm, respectively]. Correcting this offset yielded a 3-fold improvement in accuracy and precision when characterizing DNA's overstretching transition. We also demonstrated high throughput by acquiring 88 geometrically corrected force-extension curves of a single individual 100 nm DNA molecule in ∼40 min and versatility by aligning polyprotein- and PEG-based protein-ligand assays. Importantly, our software-based algorithm was implemented on a commercial AFM, so it can be broadly adopted. More generally, this work illustrates how to enhance AFM-based SMFS by developing more sophisticated data-acquisition protocols.

  12. Semi-Tomographic Gamma Scanning Technique for Non-Destructive Assay of Radioactive Waste Drums

    NASA Astrophysics Data System (ADS)

    Gu, Weiguo; Rao, Kaiyuan; Wang, Dezhong; Xiong, Jiemei

    2016-12-01

    Segmented gamma scanning (SGS) and tomographic gamma scanning (TGS) are two traditional detection techniques for low and intermediate level radioactive waste drum. This paper proposes one detection method named semi-tomographic gamma scanning (STGS) to avoid the poor detection accuracy of SGS and shorten detection time of TGS. This method and its algorithm synthesize the principles of SGS and TGS. In this method, each segment is divided into annual voxels and tomography is used in the radiation reconstruction. The accuracy of STGS is verified by experiments and simulations simultaneously for the 208 liter standard waste drums which contains three types of nuclides. The cases of point source or multi-point sources, uniform or nonuniform materials are employed for comparison. The results show that STGS exhibits a large improvement in the detection performance, and the reconstruction error and statistical bias are reduced by one quarter to one third or less for most cases if compared with SGS.

  13. Accurate virus quantitation using a Scanning Transmission Electron Microscopy (STEM) detector in a scanning electron microscope.

    PubMed

    Blancett, Candace D; Fetterer, David P; Koistinen, Keith A; Morazzani, Elaine M; Monninger, Mitchell K; Piper, Ashley E; Kuehl, Kathleen A; Kearney, Brian J; Norris, Sarah L; Rossi, Cynthia A; Glass, Pamela J; Sun, Mei G

    2017-10-01

    A method for accurate quantitation of virus particles has long been sought, but a perfect method still eludes the scientific community. Electron Microscopy (EM) quantitation is a valuable technique because it provides direct morphology information and counts of all viral particles, whether or not they are infectious. In the past, EM negative stain quantitation methods have been cited as inaccurate, non-reproducible, and with detection limits that were too high to be useful. To improve accuracy and reproducibility, we have developed a method termed Scanning Transmission Electron Microscopy - Virus Quantitation (STEM-VQ), which simplifies sample preparation and uses a high throughput STEM detector in a Scanning Electron Microscope (SEM) coupled with commercially available software. In this paper, we demonstrate STEM-VQ with an alphavirus stock preparation to present the method's accuracy and reproducibility, including a comparison of STEM-VQ to viral plaque assay and the ViroCyt Virus Counter. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Prospective validation of an automated chemiluminescence-based assay of renin and aldosterone for the work-up of arterial hypertension.

    PubMed

    Rossi, Gian Paolo; Ceolotto, Giulio; Rossitto, Giacomo; Seccia, Teresa Maria; Maiolino, Giuseppe; Berton, Chiara; Basso, Daniela; Plebani, Mario

    2016-09-01

    The availability of simple and accurate assays of plasma active renin (DRC) and aldosterone concentration (PAC) can improve the detection of secondary forms of arterial hypertension. Thus, we investigated the performance of an automated chemiluminescent assay for DRC and PAC in referred hypertensive patients. We prospectively recruited 260 consecutive hypertensive patients referred to an ESH Center for Hypertension. After exclusion of six protocol violations, 254 patients were analyzed: 67.3% had primary hypertension, 17.3% an aldosterone producing adenoma (APA), 11.4% idiopathic hyperaldosteronism (IHA), 2.4% renovascular hypertension (RVH), 0.8% familial hyperaldosteronism type 1 (FH-1), 0.4% apparent mineralocorticoid excess (AME), 0.4% a renin-producing tumor, and 3.9% were adrenalectomized APA patients. Bland-Altman plots and Deming regression were used to analyze results. The diagnostic accuracy (area under the curve, AUC of the ROC) of the DRC-based aldosterone-renin ratio (ARRCL) was compared with that of the PRA-based ARR (ARRRIA) using as reference the conclusive diagnosis of APA. At Bland-Altman plot, the DRC and PAC assay showed no bias as compared to the PRA and PAC assay. A tight relation was found between the DRC and the PRA values (concordance correlation coefficient=0.92, p<0.0001) and the PAC values measured with radioimmunoassay and chemiluminescence (concordance correlation coefficient=0.93, p<0.001). For APA identification the AUC of the ARRCL was higher than that of the ARRRIA [0.974 (95% CI 0.940-0.991) vs. 0.894 (95% CI 0.841-0.933), p=0.02]. This rapid automated chemiluminescent DRC/PAC assay performed better than validated PRA/PAC radioimmunoassays for the identification of APA in referred hypertensive patients.

  15. Evaluation of the Abbott realtime HCV genotype II RUO (GT II) assay with reference to 5'UTR, core and NS5B sequencing.

    PubMed

    Mallory, Melanie A; Lucic, Danijela X; Sears, Mitchell T; Cloherty, Gavin A; Hillyard, David R

    2014-05-01

    HCV genotyping is a critical tool for guiding initiation of therapy and selecting the most appropriate treatment regimen. To evaluate the concordance between the Abbott GT II assay and genotyping by sequencing subregions of the HCV 5'UTR, core and NS5B. The Abbott assay was used to genotype 127 routine patient specimens and 35 patient specimens with unusual subtypes and mixed infection. Abbott results were compared to genotyping by 5'UTR, core and NS5B sequencing. Sequences were genotyped using the NCBI non-redundant database and the online genotyping tool COMET. Among routine specimens, core/NS5B sequencing identified 93 genotype 1s, 13 genotype 2s, 15 genotype 3s, three genotype 4s, two genotype 6s and one recombinant specimen. Genotype calls by 5'UTR, core, NS5B sequencing and the Abbott assay were 97.6% concordant. Core/NS5B sequencing identified two discrepant samples as genotype 6 (subtypes 6l and 6u) while Abbott and 5'UTR sequencing identified these samples as genotype 1 with no subtype. The Abbott assay subtyped 91.4% of genotype 1 specimens. Among the 35 rare specimens, the Abbott assay inaccurately genotyped 3k, 6e, 6o, 6q and one genotype 4 variant; gave indeterminate results for 3g, 3h, 4r, 6m, 6n, and 6q specimens; and agreed with core/NS5B sequencing for mixed specimens. The Abbott assay is an automated HCV genotyping method with improved accuracy over 5'UTR sequencing. Samples identified by the Abbott assay as genotype 1 with no subtype may be rare subtypes of other genotypes and thus require confirmation by another method. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. An Accuracy--Response Time Capacity Assessment Function that Measures Performance against Standard Parallel Predictions

    ERIC Educational Resources Information Center

    Townsend, James T.; Altieri, Nicholas

    2012-01-01

    Measures of human efficiency under increases in mental workload or attentional limitations are vital in studying human perception, cognition, and action. Assays of efficiency as workload changes have typically been confined to either reaction times (RTs) or accuracy alone. Within the realm of RTs, a nonparametric measure called the "workload…

  17. Determining the analytical specificity of PCR-based assays for the diagnosis of IA: What is Aspergillus?

    PubMed

    Morton, C Oliver; White, P Lewis; Barnes, Rosemary A; Klingspor, Lena; Cuenca-Estrella, Manuel; Lagrou, Katrien; Bretagne, Stéphane; Melchers, Willem; Mengoli, Carlo; Caliendo, Angela M; Cogliati, Massimo; Debets-Ossenkopp, Yvette; Gorton, Rebecca; Hagen, Ferry; Halliday, Catriona; Hamal, Petr; Harvey-Wood, Kathleen; Jaton, Katia; Johnson, Gemma; Kidd, Sarah; Lengerova, Martina; Lass-Florl, Cornelia; Linton, Chris; Millon, Laurence; Morrissey, C Orla; Paholcsek, Melinda; Talento, Alida Fe; Ruhnke, Markus; Willinger, Birgit; Donnelly, J Peter; Loeffler, Juergen

    2017-06-01

    A wide array of PCR tests has been developed to aid the diagnosis of invasive aspergillosis (IA), providing technical diversity but limiting standardisation and acceptance. Methodological recommendations for testing blood samples using PCR exist, based on achieving optimal assay sensitivity to help exclude IA. Conversely, when testing more invasive samples (BAL, biopsy, CSF) emphasis is placed on confirming disease, so analytical specificity is paramount. This multicenter study examined the analytical specificity of PCR methods for detecting IA by blind testing a panel of DNA extracted from a various fungal species to explore the range of Aspergillus species that could be detected, but also potential cross reactivity with other fungal species. Positivity rates were calculated and regression analysis was performed to determine any associations between technical specifications and performance. The accuracy of Aspergillus genus specific assays was 71.8%, significantly greater (P < .0001) than assays specific for individual Aspergillus species (47.2%). For genus specific assays the most often missed species were A. lentulus (25.0%), A. versicolor (24.1%), A. terreus (16.1%), A. flavus (15.2%), A. niger (13.4%), and A. fumigatus (6.2%). There was a significant positive association between accuracy and using an Aspergillus genus PCR assay targeting the rRNA genes (P = .0011). Conversely, there was a significant association between rRNA PCR targets and false positivity (P = .0032). To conclude current Aspergillus PCR assays are better suited for detecting A. fumigatus, with inferior detection of most other Aspergillus species. The use of an Aspergillus genus specific PCR assay targeting the rRNA genes is preferential. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Evaluation of an antibody avidity index method for detecting recent human immunodeficiency virus type 1 infection using an automated chemiluminescence immunoassay.

    PubMed

    Fernández, Gema; Manzardo, Christian; Montoliu, Alexandra; Campbell, Colin; Fernández, Gregorio; Casabona, Jordi; Miró, José Maria; Matas, Lurdes; Rivaya, Belén; González, Victoria

    2015-04-01

    Recent infection testing algorithms (RITAs) are used in public health surveillance to estimate the incidence of recently acquired HIV-1 infection. Our aims were (i) to evaluate the precision of the VITROS® Anti-HIV 1+2 automated antibody avidity assay for qualitative detection of antibodies to HIV 1+2 virus; (ii) to validate the accuracy of an automated guanidine-based antibody avidity assay to discriminate between recent and long standing infections using the VITROS 3600 platform; (iii) to compare this method with BED-CEIA assay; and (iv) to evaluate the occurrence of false recent misclassifications by the VITROS antibody avidity assay in patients with a CD4 count <200 cells/μL and in patients on combination antiretroviral therapy (cART). The VITROS® antibody avidity assay is highly reproducible. The ROC curve analysis of the accuracy of this assay, optimized for sensitivity and specificity, had an AI cut off of ≤0.51, with sensitivity and specificity values of 86.67% (95% CI: 72.51-94.46) and 86.24% (95% CI: 78.00-91.84), respectively. The agreement between VITROS antibody avidity and BED-CEIA assays was good. Misclassifications of long standing infections as recent infection occurred in 8.2% of patients with CD4 <200 cell/μL and 8.7% in patients on combination antiretroviral therapy. The VITROS antibody avidity assay is a reliable serological method to detect recent HIV-1 infections and it could be incorporated into a RITA to estimate HIV incidence. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  19. Building predictive in vitro pulmonary toxicity assays using high-throughput imaging and artificial intelligence.

    PubMed

    Lee, Jia-Ying Joey; Miller, James Alastair; Basu, Sreetama; Kee, Ting-Zhen Vanessa; Loo, Lit-Hsin

    2018-06-01

    Human lungs are susceptible to the toxicity induced by soluble xenobiotics. However, the direct cellular effects of many pulmonotoxic chemicals are not always clear, and thus, a general in vitro assay for testing pulmonotoxicity applicable to a wide variety of chemicals is not currently available. Here, we report a study that uses high-throughput imaging and artificial intelligence to build an in vitro pulmonotoxicity assay by automatically comparing and selecting human lung-cell lines and their associated quantitative phenotypic features most predictive of in vivo pulmonotoxicity. This approach is called "High-throughput In vitro Phenotypic Profiling for Toxicity Prediction" (HIPPTox). We found that the resulting assay based on two phenotypic features of a human bronchial epithelial cell line, BEAS-2B, can accurately classify 33 reference chemicals with human pulmonotoxicity information (88.8% balance accuracy, 84.6% sensitivity, and 93.0% specificity). In comparison, the predictivity of a standard cell-viability assay on the same set of chemicals is much lower (77.1% balanced accuracy, 84.6% sensitivity, and 69.5% specificity). We also used the assay to evaluate 17 additional test chemicals with unknown/unclear human pulmonotoxicity, and experimentally confirmed that many of the pulmonotoxic reference and predicted-positive test chemicals induce DNA strand breaks and/or activation of the DNA-damage response (DDR) pathway. Therefore, HIPPTox helps us to uncover these common modes-of-action of pulmonotoxic chemicals. HIPPTox may also be applied to other cell types or models, and accelerate the development of predictive in vitro assays for other cell-type- or organ-specific toxicities.

  20. Multivariate models for prediction of human skin sensitization hazard.

    PubMed

    Strickland, Judy; Zang, Qingda; Paris, Michael; Lehmann, David M; Allen, David; Choksi, Neepa; Matheson, Joanna; Jacobs, Abigail; Casey, Warren; Kleinstreuer, Nicole

    2017-03-01

    One of the Interagency Coordinating Committee on the Validation of Alternative Method's (ICCVAM) top priorities is the development and evaluation of non-animal approaches to identify potential skin sensitizers. The complexity of biological events necessary to produce skin sensitization suggests that no single alternative method will replace the currently accepted animal tests. ICCVAM is evaluating an integrated approach to testing and assessment based on the adverse outcome pathway for skin sensitization that uses machine learning approaches to predict human skin sensitization hazard. We combined data from three in chemico or in vitro assays - the direct peptide reactivity assay (DPRA), human cell line activation test (h-CLAT) and KeratinoSens™ assay - six physicochemical properties and an in silico read-across prediction of skin sensitization hazard into 12 variable groups. The variable groups were evaluated using two machine learning approaches, logistic regression and support vector machine, to predict human skin sensitization hazard. Models were trained on 72 substances and tested on an external set of 24 substances. The six models (three logistic regression and three support vector machine) with the highest accuracy (92%) used: (1) DPRA, h-CLAT and read-across; (2) DPRA, h-CLAT, read-across and KeratinoSens; or (3) DPRA, h-CLAT, read-across, KeratinoSens and log P. The models performed better at predicting human skin sensitization hazard than the murine local lymph node assay (accuracy 88%), any of the alternative methods alone (accuracy 63-79%) or test batteries combining data from the individual methods (accuracy 75%). These results suggest that computational methods are promising tools to identify effectively the potential human skin sensitizers without animal testing. Published 2016. This article has been contributed to by US Government employees and their work is in the public domain in the USA. Published 2016. This article has been contributed to by US Government employees and their work is in the public domain in the USA.

  1. Genetic origin of α0-thalassemia (SEA deletion) in Southeast Asian populations and application to accurate prenatal diagnosis of Hb Bart's hydrops fetalis syndrome.

    PubMed

    Jomoui, Wittaya; Fucharoen, Goonnapa; Sanchaisuriya, Kanokwan; Charoenwijitkul, Patnaree; Maneesarn, Jitpanu; Xu, Xiangmin; Fucharoen, Supan

    2017-08-01

    α 0 -thalassemia of SEA deletion (- SEA ) is common among Southeast Asian and Chinese. Using haplotype and phylogenetic analyses, we examined the origin of this defect in Southeast Asian populations. Study was done on both normal and α 0 -thalassemia alleles in 3 ethnic groups including 96 Thai, 52 Laotian and 21 Cambodian. Five SNPs encompassing the (- SEA ) including (rs3760053 T>G), (rs1211375 A>C), (rs3918352 A>G), (rs1203974 A>G) and (rs11248914 C>T) were examined using high-resolution melting assays. It was found that 94.0% of Thai, 100% of Laotian and 100% of Cambodian α 0 -thalassemia alleles were linked to the same haplotype: the haplotype H4 (AAGC), representing an Asian specific origin. An G allele of the (rs3760053) was found to be in strong linkage disequilibrium with the α 0 -thalassemia allele in these populations. A multiplex PCR assay was developed to detect simultaneously the (- SEA ) allele and genotyping of a linked (rs3760053) to improve accuracy of prenatal diagnosis of α 0 -thalassemia. Application of this multiplex PCR assay for routine prenatal diagnosis of α 0 -thalassemia in 12 families revealed a 100% concordant result with conventional gap-PCR assay. Therefore, a single genetic origin is responsible for the spread and high prevalence of the (- SEA ) in the region. The multiplex PCR assay developed should provide a double-check PCR system for more accurate diagnosis and allow the monitoring of possible maternal contamination at prenatal diagnosis of this important genetic disorder.

  2. The assessment of serum-mediated phagocytosis of necrotic material by polymorphonuclear leukocytes to diagnose and predict the clinical features of systemic lupus erythematosus: an observational longitudinal study.

    PubMed

    Compagno, Michele; Gullstrand, Birgitta; Jacobsen, Søren; Eilertsen, Gro Ø; Nilsson, Jan Åke; Lood, Christian; Jönsen, Andreas; Truedsson, Lennart; Sturfelt, Gunnar; Bengtsson, Anders A

    2016-02-10

    Serum-mediated phagocytosis of antibody- and complement-opsonized necrotic cell material (NCM) by polymorphonuclear leukocytes can be quantified by using a flow cytometry-based assay. The phagocytosis of necrotic cell material (PNC) assay parallels the well-known lupus erythematosus cell test. In this study, we aimed to investigate the diagnostic accuracy of the assay and the relationship with clinical manifestations and disease activity in systemic lupus erythematosus (SLE). The diagnostic accuracy for SLE diagnosis of the PNC assay was studied by cross-sectional assessment of blood samples from 148 healthy control subjects and a multicenter rheumatic group (MRG) of 529 patients with different rheumatic symptoms. A cohort of 69 patients with an established SLE diagnosis (SLE cohort) underwent longitudinal clinical and laboratory follow-up for analysis of the temporal relationships between PNC positivity and specific clinical manifestations. In 35 of 529 MRG patients, 13 of whom had SLE, the PNC assay result was positive. Combined positivity of the PNC assay and anti-double-stranded DNA antibodies increased specificity and positive predictive value for SLE diagnosis to 0.99 and 0.67, respectively. In the longitudinal study, 42 of 69 SLE cohort patients had positive results in the PNC assay at least once. PNC assay positivity was associated with current hematological manifestations and could predict mucocutaneous manifestations. When combined with hypocomplementemia, PNC positivity preceded increased Systemic Lupus Erythematosus Disease Activity Index 2000 score, glomerulonephritis, and alopecia. Serum-mediated PNC by polymorphonuclear leukocytes is commonly but not exclusively seen in patients with SLE. The PNC assay may be used in follow-up of patients with SLE and, especially in combination with other routinely assessed laboratory tests, may help to predict flares and different clinical manifestations, including glomerulonephritis. Our results encourage further development of the PNC assay as a complementary laboratory tool in management of patients with SLE.

  3. A digital enzyme-linked immunosorbent assay for ultrasensitive measurement of amyloid-β 1-42 peptide in human plasma with utility for studies of Alzheimer's disease therapeutics.

    PubMed

    Song, Linan; Lachno, D Richard; Hanlon, David; Shepro, Adam; Jeromin, Andreas; Gemani, Dipika; Talbot, Jayne A; Racke, Margaret M; Dage, Jeffrey L; Dean, Robert A

    2016-12-15

    Amyloid-β 1-42 peptide (Aβ 1-42 ) is associated with plaque formation in the brain of patients with Alzheimer's disease (AD). Pharmacodynamic studies of AD therapeutics that lower the concentrations of Aβ 1-42 in peripheral blood require highly sensitive assays for its measurement. A digital enzyme-linked immunosorbent assay (ELISA) using single molecule array (Simoa) technology has been developed that provides improved sensitivity compared with conventional ELISA methods using the same antibody reagents. A sensitive digital ELISA for measurement of Aβ 1-42 using antibodies 3D6 and 21F12 was developed. Assay performance was evaluated by repeated testing of pooled human plasma and buffer diluent quality control samples to determine relative accuracy, intra- and inter-assay precision, limit of detection (LOD), lower limit of quantification (LLOQ), dilutional linearity, and spike recovery. The optimized assay was used to quantify Aβ 1-42 in clinical samples from patients treated with the β-site amyloid precursor protein cleaving enzyme 1 inhibitor LY2886721. The prototype assay measured Aβ 1-42 with an LOD of 0.3 pg/ml and an LLOQ of 2.8 pg/ml in plasma, calibrated using an Aβ 1-42 peptide standard from Fujirebio. Assay precision was acceptable with intra- and inter-assay coefficients of variation both being ≤10%. Dilutional linearity was demonstrated in sample diluent and immunodepleted human plasma. Analyte spike recovery ranged from 51% to 93% with a mean of 80%. This assay was able to quantify Aβ 1-42 in all of the 84 clinical samples tested. A rapid reduction in levels of Aβ 1-42 was detected within 1 h after drug treatment, and a dose-dependent decrease of Aβ 1-42 levels was also observed over the time course of sample collection. This digital ELISA has potential utility in clinical applications for quantification of Aβ 1-42 in plasma where high sensitivity and precision are required.

  4. Breakthrough invasive aspergillosis and diagnostic accuracy of serum galactomannan enzyme immune assay during acute myeloid leukemia induction chemotherapy with posaconazole prophylaxis

    PubMed Central

    Calmettes, Claire; Gabriel, Frederic; Blanchard, Elodie; Servant, Vincent; Bouchet, Stéphane; Kabore, Nathanael; Forcade, Edouard; Leroyer, Camille; Bidet, Audrey; Latrabe, Valérie; Leguay, Thibaut; Vigouroux, Stephane; Tabrizi, Reza; Breilh, Dominique; Accoceberry, Isabelle; de Lara, Manuel Tunon; Pigneux, Arnaud; Milpied, Noel; Dumas, Pierre-Yves

    2018-01-01

    Posaconazole prophylaxis has demonstrated efficacy in the prevention of invasive aspergillosis during prolonged neutropenia following acute myeloid leukemia induction chemotherapy. Antifungal treatment decreases serum galactomannan enzyme immunoassay diagnostic accuracy that could delay the diagnosis and treatment. We retrospectively studied patients with acute myeloid leukemia who underwent intensive chemotherapy and antifungal prophylaxis by posaconazole oral suspension. Clinical, radiological, microbiological features and treatment response of patients with invasive aspergillosis that occurred despite posaconazole prophylaxis were analyzed. Diagnostic accuracy of serum galactomannan assay according to posaconazole plasma concentrations has been performed. A total of 288 patients with acute myeloid leukemia, treated by induction chemotherapy, who received posaconazole prophylaxis for more than five days were included in the present study. The incidence of invasive aspergillosis was 8% with 12 (4.2%), 8 (2.8%) and 3 (1%), possible, probable and proven invasive aspergillosis, respectively. Posaconazole plasma concentration was available for 258 patients. Median duration of posaconazole treatment was 17 days, and median posaconazole plasma concentration was 0.5 mg/L. None of patients with invasive aspergillosis and posaconazole concentration ≥ 0.5 mg/L had a serum galactomannan positive test. Sensitivity of serum galactomannan assay to detect probable and proven invasive aspergillosis was 81.8%. Decreasing the cut-off value for serum galactomannan optical density index from 0.5 to 0.3 increased sensitivity to 90.9%. In a homogenous cohort of acute myeloid leukemia patients during induction chemotherapy, increasing the posaconazole concentration decreases the sensitivity of serum galactomannan assay.

  5. Validation of a Spectral Method for Quantitative Measurement of Color in Protein Drug Solutions.

    PubMed

    Yin, Jian; Swartz, Trevor E; Zhang, Jian; Patapoff, Thomas W; Chen, Bartolo; Marhoul, Joseph; Shih, Norman; Kabakoff, Bruce; Rahimi, Kimia

    2016-01-01

    A quantitative spectral method has been developed to precisely measure the color of protein solutions. In this method, a spectrophotometer is utilized for capturing the visible absorption spectrum of a protein solution, which can then be converted to color values (L*a*b*) that represent human perception of color in a quantitative three-dimensional space. These quantitative values (L*a*b*) allow for calculating the best match of a sample's color to a European Pharmacopoeia reference color solution. In order to qualify this instrument and assay for use in clinical quality control, a technical assessment was conducted to evaluate the assay suitability and precision. Setting acceptance criteria for this study required development and implementation of a unique statistical method for assessing precision in 3-dimensional space. Different instruments, cuvettes, protein solutions, and analysts were compared in this study. The instrument accuracy, repeatability, and assay precision were determined. The instrument and assay are found suitable for use in assessing color of drug substances and drug products and is comparable to the current European Pharmacopoeia visual assessment method. In the biotechnology industry, a visual assessment is the most commonly used method for color characterization, batch release, and stability testing of liquid protein drug solutions. Using this method, an analyst visually determines the color of the sample by choosing the closest match to a standard color series. This visual method can be subjective because it requires an analyst to make a judgment of the best match of color of the sample to the standard color series, and it does not capture data on hue and chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we developed a quantitative spectral method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. In this study, we established a statistical method for assessing precision in 3-dimensional space and demonstrated that the quantitative spectral method is comparable with respect to precision and accuracy to the current European Pharmacopoeia visual assessment method. © PDA, Inc. 2016.

  6. Cryogenic gamma detectors enable direct detection of 236U and minor actinides for non-destructive assay [Cryogenic gamma detectors enable direct detection of minor actinides for non-destructive assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Velazquez, Miguel; Dreyer, Jonathan; Drury, Owen B.

    2015-09-05

    Here, we demonstrate the utility of a superconducting transition edge sensor (TES) γ-ray detector with high energy resolution and low Compton background for non-destructive assay (NDA) of a uranium sample from reprocessed nuclear fuel. We show that TES γ-detectors can separate low energy actinide γ-emissions from the background and nearby lines, even from minor isotopes whose signals are often obscured in NDA with conventional Ge detectors. Superconducting γ detectors may therefore bridge the gap between high-accuracy destructive assay (DA) and easier to-use NDA.

  7. A novel clot lysis assay for recombinant plasminogen activator.

    PubMed

    Jamialahmadi, Oveis; Fazeli, Ahmad; Hashemi-Najafabadi, Sameereh; Fazeli, Mohammad Reza

    2015-03-01

    Recombinant plasminogen activator (r-PA, reteplase) is an engineered variant of alteplase. When expressed in E. coli, it appears as inclusion bodies that require refolding to recover its biological activity. An important step following refolding is to determine the activity of refolded protein. Current methods for enzymatic activity of thrombolytic drugs are costly and complex. Here a straightforward and low-cost clot lysis assay was developed. It quantitatively measures the activity of the commercial reteplase and is also capable of screening refolding conditions. As evidence for adequate accuracy and sensitivity of the current assay, r-PA activity measurements are shown to be comparable to those obtained from chromogenic substrate assay.

  8. Performance evaluation of the Abbott RealTime HCV Genotype II for hepatitis C virus genotyping.

    PubMed

    Sohn, Yong-Hak; Ko, Sun-Young; Kim, Myeong Hee; Oh, Heung-Bum

    2010-04-01

    The Abbott RealTime hepatitis C virus (HCV) Genotype II (Abbott Molecular Inc.) for HCV genotyping, which uses real-time PCR technology, has recently been developed. Accuracy and sensitivity of detection were assessed using the HCV RNA PHW202 performance panel (SeraCare Life Sciences). Consistency with restriction fragment mass polymorphism (RFMP) data, cross-reactivity with other viruses, and the ability to detect minor strains in mixtures of genotypes 1 and 2 were evaluated using clinical samples. All performance panel viruses were correctly genotyped at levels of >500 IU/mL. Results were 100% concordant with RFMP genotypic data (66/66). However, 5% (3/66) of the samples examined displayed probable genotypic cross reactivity. No cross reactivity with other viruses was evident. Minor strains in the mixtures were not effectively distinguished, even at quantities higher than the detection limit. The Abbott RealTime HCV Genotype II assay was very accurate and yielded results consistent with RFMP data. Although the assay has the advantages of automation and short turnaround time, we suggest that further improvements are necessary before it is used routinely in clinical practice. Efforts are needed to decrease cross reactivity among genotypes and to improve the ability to detect minor genotypes in mixed infections.

  9. Studies of plant colonisation by closely related Bacillus amyloliquefaciens biocontrol agents using strain specific quantitative PCR assays.

    PubMed

    Johansson, Anna H; Bejai, Sarosh; Niazi, Adnan; Manzoor, Shahid; Bongcam-Rudloff, Erik; Meijer, Johan

    2014-12-01

    Certain strains of Bacillus amyloliquefaciens can colonize plants and improve growth and stress management. In order to study these effects, bacterial growth dynamics on plants and in the rhizosphere are of interest calling for specific analytical tools. For that purpose, quantitative real-time PCR (qPCR) assays were developed in order to differentiate among three closely related B. amyloliquefaciens subsp. plantarum strains (UCMB5033, UCMB5036, UCMB5113) and to determine their levels with high accuracy. Oligonucleotide primers were designed for strain unique gene sequences and used for SYBR green based qPCR analysis. Standard curves covered a wide linear range (10(6)) of DNA amounts with the lowest detection level at 50 fg. Post-reaction melting curve analysis showed only a single product. Accurate threshold cycles were obtained, even in the presence of high excess of related Bacillus strains and total bacterial DNA from soil. Analysis of Bacillus colonisation after seed treatment of two oilseed rape cultivars (Oase and Ritz) grown on agar support showed a time dependent effect but that the bacteria mostly were found on root tissues and little on green tissues. The colonisation on plants grown in soil varied among the Bacillus strains where Oase seemed to house more bacteria than Ritz. Applied as a mixture, all three Bacillus strains co-existed on the roots of plants grown in soil. The qPCR assay in combination with other techniques will be a powerful tool to study plant interactions of these B. amyloliquefaciens biocontrol agents to further understand the requirements for successful interactions and improvement of plant properties.

  10. Comparison of spectroscopically measured finger and forearm tissue ethanol concentration to blood and breath ethanol measurements

    NASA Astrophysics Data System (ADS)

    Ridder, Trent D.; Hull, Edward L.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2011-02-01

    Previous works investigated a spectroscopic technique that offered a promising alternative to blood and breath assays for determining in vivo alcohol concentration. Although these prior works measured the dorsal forearm, we report the results of a 26-subject clinical study designed to evaluate the spectroscopic technique at a finger measurement site through comparison to contemporaneous forearm spectroscopic, venous blood, and breath measurements. Through both Monte Carlo simulation and experimental data, it is shown that tissue optical probe design has a substantial impact on the effective path-length of photons through the skin and the signal-to-noise ratio of the spectroscopic measurements. Comparison of the breath, blood, and tissue assays demonstrated significant differences in alcohol concentration that are attributable to both assay accuracy and alcohol pharmacokinetics. Similar to past works, a first order kinetic model is used to estimate the fraction of concentration variance explained by alcohol pharmacokinetics (72.6-86.7%). A significant outcome of this work was significantly improved pharmacokinetic agreement with breath (arterial) alcohol of the finger measurement (mean kArt-Fin = 0.111 min-1) relative to the forearm measurement (mean kArt-For = 0.019 min-1) that is likely due to the increased blood perfusion of the finger.

  11. A method for the direct injection and analysis of small volume human blood spots and plasma extracts containing high concentrations of organic solvents using revered-phase 2D UPLC/MS.

    PubMed

    Rainville, Paul D; Simeone, Jennifer L; Root, Dan S; Mallet, Claude R; Wilson, Ian D; Plumb, Robert S

    2015-03-21

    The emergence of micro sampling techniques holds great potential to improve pharmacokinetic data quality, reduce animal usage, and save costs in safety assessment studies. The analysis of these samples presents new challenges for bioanalytical scientists, both in terms of sample processing and analytical sensitivity. The use of two dimensional LC/MS with, at-column-dilution for the direct analysis of highly organic extracts prepared from biological fluids such as dried blood spots and plasma is demonstrated. This technique negated the need to dry down and reconstitute, or dilute samples with water/aqueous buffer solutions, prior to injection onto a reversed-phase LC system. A mixture of model drugs, including bromhexine, triprolidine, enrofloxacin, and procaine were used to test the feasibility of the method. Finally an LC/MS assay for the probe pharmaceutical rosuvastatin was developed from dried blood spots and protein-precipitated plasma. The assays showed acceptable recovery, accuracy and precision according to US FDA guidelines. The resulting analytical method showed an increase in assay sensitivity of up to forty fold as compared to conventional methods by maximizing the amount loaded onto the system and the MS response for the probe pharmaceutical rosuvastatin from small volume samples.

  12. Unlabeled Oligonucleotides as Internal Temperature Controls for Genotyping by Amplicon Melting

    PubMed Central

    Seipp, Michael T.; Durtschi, Jacob D.; Liew, Michael A.; Williams, Jamie; Damjanovich, Kristy; Pont-Kingdon, Genevieve; Lyon, Elaine; Voelkerding, Karl V.; Wittwer, Carl T.

    2007-01-01

    Amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, or allele-specific polymerase chain reaction. However, correct differentiation of homozygous mutant and wild-type samples by melting temperature (Tm) requires high-resolution melting and closely controlled reaction conditions. When three different DNA extraction methods were used to isolate DNA from whole blood, amplicon Tm differences of 0.03 to 0.39°C attributable to the extractions were observed. To correct for solution chemistry differences between samples, complementary unlabeled oligonucleotides were included as internal temperature controls to shift and scale the temperature axis of derivative melting plots. This adjustment was applied to a duplex amplicon melting assay for the methylenetetrahydrofolate reductase variants 1298A>C and 677C>T. High- and low-temperature controls bracketing the amplicon melting region decreased the Tm SD within homozygous genotypes by 47 to 82%. The amplicon melting assay was 100% concordant to an adjacent hybridization probe (HybProbe) melting assay when temperature controls were included, whereas a 3% error rate was observed without temperature correction. In conclusion, internal temperature controls increase the accuracy of genotyping by high-resolution amplicon melting and should also improve results on lower resolution instruments. PMID:17591926

  13. Simultaneous determination of phosphatidylcholine-derived quaternary ammonium compounds by a LC-MS/MS method in human blood plasma, serum and urine samples.

    PubMed

    Steuer, Christian; Schütz, Philipp; Bernasconi, Luca; Huber, Andreas R

    2016-01-01

    The determination of circulating trimethylamine-N-oxide (TMAO), choline, betaine, l-carnitine and O-acetyl-l-carnitine concentration in different human matrices is of great clinical interest. Recent results highlighted the prognostic value of TMAO and quaternary ammonium containing metabolites in the field of cardiovascular and kidney diseases. Herein, we report a method for the rapid and simultaneous measurement of closely related phosphatidylcholine-derived metabolites in three different biological matrices by stable isotope dilution assay. Plasma, serum and urine samples were simply deproteinized and separated by HILIC-chromatography. Detection and quantification were performed using LC-MS/MS with electrospray ionization in positive mode. For accuracy and precision, full calibration was performed covering more than the full reference range. Assay performance metrics include intra- and interday imprecision were below 10% for all analytes. To exclude matrix effects standard addition methods were applied for all matrices. It was shown that calibration standards and quality control prepared in water can be used instead of matrix-matched calibration and controls. The LC/MS/MS-based assay described in this article may improve future clinical studies evaluating TMAO and related substances as prognostic markers for cardiovascular risk and all-cause mortality in different patient populations. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Use of the Filovirus Animal Non-Clinical Group (FANG) Ebola virus immuno-assay requires fewer study participants to power a study than the Alpha Diagnostic International assay

    PubMed Central

    Logue, James; Tuznik, Kaylie; Follmann, Dean; Grandits, Greg; Marchand, Jonathan; Reilly, Cavan; Sarro, Yeya dit Sadio; Pettitt, James; Stavale, Eric J.; Fallah, Mosoka; Olinger, Gene G.; Bolay, Fatorma K.; Hensley, Lisa E.

    2018-01-01

    As part of the scientific community’s development of medical countermeasures against Ebola virus disease, optimization of standardized assays for product evaluation is paramount. The recent outbreak heightened awareness to the scarcity of available assays and limited information on performance and reproducibility. To evaluate the immunogenicity of vaccines entering Phase I–III trials and to identify survivors, two enzyme-linked immunosorbent assays, the Filovirus Animal Non-Clinical Group assay and the Alpha Diagnostics International assay, were evaluated for detection of immunoglobulin G against Ebola virus glycoprotein. We found that the Filovirus Animal Nonclinical Group assay produced a wider range of relative antibody concentrations, higher assay precision, larger relative accuracy range, and lower regional background. Additionally, to sufficiently power a vaccine trial, use of the Filovirus Animal Nonclinical Group assay would require one third the number of participants than the Alpha Diagnostics International assay. This reduction in needed study participants will require less money, fewer man hours, and much less time to evaluate vaccine immunogenicity. PMID:29481881

  15. Simultaneous titration and phenotypic antiviral drug susceptibility testing for herpes simplex virus 1 and 2.

    PubMed

    Tardif, Keith D; Jorgensen, Shane; Langer, Janine; Prichard, Mark; Schlaberg, Robert

    2014-11-01

    Most herpes simplex virus (HSV) isolates from treatment-naïve patients are susceptible to antivirals. However, prolonged antiviral therapy can select for drug-resistant strains, especially in immunocompromised patients. Standard phenotypic methods for antiviral resistance testing are labor and time-intense and molecular resistance determinants are insufficiently understood for routine diagnostic use of genotypic resistance testing. To enable rapid, scalable antiviral susceptibility testing and minimize viral passage, we developed a 7-day, 96-well assay for simultaneous HSV 1/2 titration and phenotypic resistance testing for acyclovir and foscarnet. The assay was optimized and validated by testing clinical isolates and laboratory strains (n=39) with known IC50 for acyclovir (23 resistant) and foscarnet (1 resistant) based on plaque reduction or dye-uptake assays. A chemiluminescent detection reagent is used for quantification of cytopathic effect instead of plaque counting or measuring dye-uptake. Drug concentrations inhibiting 50% of chemiluminescent signal reduction (IC50) were determined concurrently at each of three virus dilutions. Results agree for 92.3% (acyclovir) and 100% (foscarnet) of isolates. For all three discordant samples, results of reference testing by plaque reduction agreed with the chemiluminescent assay. Reproducibility studies showed 100% qualitative agreement and 3-37% coefficient of variation based on IC50. Chemiluminescence detection as a surrogate for cellular viability with an automated plate reader provides improved throughput and workflow, as well as high accuracy and reproducibility for antiviral drug susceptibility testing. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Discordance between MTB/RIF and Real-Time Tuberculosis-Specific Polymerase Chain Reaction Assay in Bronchial Washing Specimen and Its Clinical Implications.

    PubMed

    Jo, Yong Suk; Park, Ju-Hee; Lee, Jung Kyu; Heo, Eun Young; Chung, Hee Soon; Kim, Deog Kyeom

    2016-01-01

    The prevalence and clinical implications of discordance between Xpert MTB/RIF assays and the AdvanSure TB/NTM real-time polymerase chain reaction (PCR) for bronchial washing specimens have not been studied in pulmonary TB (PTB) patients. The discordant proportion and its clinical impact were evaluated in 320 patients from the bronchoscopy registry whose bronchial washing specimens were tested simultaneously with Xpert MTB/RIF and the TB/NTM PCR assay for three years, and the accuracy of the assays, including the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), were studied. The clinical risk factors for discordance and false positivity of assays were also studied. Among 130 patients who were clinically diagnosed with PTB, 64 patients showed positive acid-fast bacilli culture results, 56 patients showed positive results in molecular methods and clinician diagnosed PTB without results of microbiology in 10 patients. The sensitivity, specificity, PPV, and NPV were 80.0%, 98.95%, 98.1%, and 87.9%, respectively, for Xpert MTB/RIF and 81.5%, 92.6%, 88.3%, and 88.0%, respectively, for TB/NTM PCR. The discordant proportion was 16.9% and was higher in culture-negative PTB compared to culture-confirmed PTB (24.3% vs. 9.4%, p = 0.024). However, there were no significant differences in the clinical characteristics, regardless of the discordance. The diagnostic yield increased with an additional assay (7.7% for Xpert MTB/RIF and 9.2% for TB/NTM PCR). False positivity was less common in patients tested with Xpert MTB/RIF (1.05% vs. 7.37%, p = 0.0035). No host-related risk factor for false positivity was identified. The Xpert MTB/RIF and TB/NTM PCR assay in bronchial washing specimens can improve the diagnostic yields for PTB, although there were considerable discordant results without any patient-related risk factors.

  17. The development of loop-mediated isothermal amplification targeting alpha-tubulin DNA for the rapid detection of Plasmodium vivax.

    PubMed

    Dinzouna-Boutamba, Sylvatrie-Danne; Yang, Hye-Won; Joo, So-Young; Jeong, Sookwan; Na, Byoung-Kuk; Inoue, Noboru; Lee, Won-Ki; Kong, Hyun-Hee; Chung, Dong-Il; Goo, Youn-Kyoung; Hong, Yeonchul

    2014-06-30

    Malaria that is caused by Plasmodium vivax is the most widely distributed human malaria. Its recent resurgence in many parts of the world, including the Republic of Korea (ROK), emphasizes the importance of improved access to the early and accurate detection of P. vivax to reduce disease burden. In this study, a rapid and efficient loop-mediated isothermal amplification (LAMP)-based method was developed and validated using blood samples from malaria-suspected patients. A LAMP assay targeting the α-tubulin gene for the detection of P. vivax was developed with six primers that recognize different regions of the target gene. The diagnostic performance of the α-tubulin LAMP assay was compared to three other tests: microscopic examinations, rapid diagnostic tests (RDTs), and nested polymerase chain reactions (PCRs) using 177 whole blood specimens obtained from ROK military personnel from May to December 2011. The α-tubulin LAMP assay was highly sensitive with a detection limit of 100 copies of P. vivax α-tubulin gene per reaction within 50 min. It specifically amplified the target gene only from P. vivax. Validation of the α-tubulin LAMP assay showed that the assay had the highest sensitivity (P < 0.001 versus microscopy; P = 0.0023 versus RDT) when nested PCR was used as the gold standard and better agreement (concordance: 94.9%, kappa value: 0.865) with nested PCR than RDT and microscopy. A Receiver Operation Characteristics analysis showed that the diagnostic accuracy of the α-tubulin LAMP assay for vivax malaria was higher (Area Under Curve = 0.908) than RDT and microscopy. This study showed that the P. vivax α-tubulin LAMP assay, which can be used to diagnose early infections of vivax malaria, is an alternative molecular diagnostic tool and a point-of-care test that may help to prevent transmission in endemic areas.

  18. Quantification of anti-Leishmania antibodies in saliva of dogs.

    PubMed

    Cantos-Barreda, Ana; Escribano, Damián; Bernal, Luis J; Cerón, José J; Martínez-Subiela, Silvia

    2017-08-15

    Detection of serum anti-Leishmania antibodies by quantitative or qualitative techniques has been the most used method to diagnose Canine Leishmaniosis (CanL). Nevertheless, saliva may represent an alternative to blood because it is easy to collect, painless and non-invasive in comparison with serum. In this study, two time-resolved immunofluorometric assays (TR-IFMAs) for quantification of anti-Leishmania IgG2 and IgA antibodies in saliva were developed and validated and their ability to distinguish Leishmania-seronegative from seropositive dogs was evaluated. The analytical study was performed by evaluation of assay precision, sensitivity and accuracy. In addition, serum from 48 dogs (21 Leishmania-seropositive and 27 Leishmania-seronegative) were analyzed by TR-IFMAs. The assays were precise, with an intra- and inter-assay coefficients of variation lower than 11%, and showed high level of accuracy, as determined by linearity under dilution (R 2 =0.99) and recovery tests (>88.60%). Anti-Leishmania IgG2 antibodies in saliva were significantly higher in the seropositive group compared with the seronegative (p<0.0001), whereas no significant differences for anti-Leishmania IgA antibodies between both groups were observed. Furthermore, TR-IFMA for quantification of anti-Leishmania IgG2 antibodies in saliva showed higher differences between seropositive and seronegative dogs than the commercial assay used in serum. In conclusion, TR-IFMAs developed may be used to quantify anti-Leishmania IgG2 and IgA antibodies in canine saliva with an adequate precision, analytical sensitivity and accuracy. Quantification of anti-Leishmania IgG2 antibodies in saliva could be potentially used to evaluate the humoral response in CanL. However, IgA in saliva seemed not to have diagnostic value for this disease. For future studies, it would be desirable to evaluate the ability of the IgG2 assay to detect dogs with subclinical disease or with low antibody titers in serum and also to study the antibodies behaviour in saliva during the treatment of CanL. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Comparison of EMIT II, CEDIA, and DPC RIA assays for the detection of lysergic acid diethylamide in forensic urine samples.

    PubMed

    Wiegand, Russell F; Klette, Kevin L; Stout, Peter R; Gehlhausen, Jay M

    2002-10-01

    In an effort to determine a practical, efficient, and economical alternative for the use of a radioimmunoassay (RIA) for the detection of lysergic acid diethylamide (LSD) in human urine, the performance of two photometric immunoassays (Dade Behring EMIT II and Microgenics CEDIA) and the Diagnostics Products Corp. (DPC) RIA were compared. Precision, accuracy, and linearity of the 3 assays were determined by testing 60 replicates (10 for RIA) at 5 different concentrations below and above the 500-pg/mL LSD cut-off. The CEDIA and RIA exhibited better accuracy and precision than the EMIT II immunoassay. In contrast, the EMIT II and CEDIA demonstrated superior linearity r2 = 0.9809 and 0.9540, respectively, as compared with the RIA (r2 = 0.9062). The specificity of the three assays was assessed using compounds that have structural and chemical properties similar to LSD, common over-the-counter products, prescription drugs and some of their metabolites, and other drugs of abuse. Of the 144 compounds studied, the EMIT II cross-reacted with twice as many compounds as did the CEDIA and RIA. Specificity was also assessed in 221 forensic human urine specimens that previously screened positive for LSD by the EMIT II assay. Of these, only 11 tested positive by CEDIA, and 3 were positive by RIA. This indicated a comparable specificity performance between CEDIA and RIA. This also was consistent with a previously reported high false-positive rate of EMIT II (low specificity). Each of the immunoassays correctly identified LSD in 23 out of 24 human urine specimens that had previously been found to contain LSD by gas chromatography-mass spectrometry at a cut-off concentration of 200 pg/mL. The CEDIA exhibited superior precision, accuracy, and decreased cross-reactivity to compounds other than LSD as compared with the EMIT II assay and does not necessitate the handling of radioactive materials.

  20. Optimal Cutoff and Accuracy of an IgM Enzyme-Linked Immunosorbent Assay for Diagnosis of Acute Scrub Typhus in Northern Thailand: an Alternative Reference Method to the IgM Immunofluorescence Assay

    PubMed Central

    Blacksell, Stuart D.; Tanganuchitcharnchai, Ampai; Jintaworn, Suthatip; Kantipong, Pacharee; Richards, Allen L.; Day, Nicholas P. J.

    2016-01-01

    The enzyme-linked immunosorbent assay (ELISA) has been proposed as an alternative serologic diagnostic test to the indirect immunofluorescence assay (IFA) for scrub typhus. Here, we systematically determine the optimal sample dilution and cutoff optical density (OD) and estimate the accuracy of IgM ELISA using Bayesian latent class models (LCMs). Data from 135 patients with undifferentiated fever were reevaluated using Bayesian LCMs. Every patient was evaluated for the presence of an eschar and tested with a blood culture for Orientia tsutsugamushi, three different PCR assays, and an IgM IFA. The IgM ELISA was performed for every sample at sample dilutions from 1:100 to 1:102,400 using crude whole-cell antigens of the Karp, Kato, and Gilliam strains of O. tsutsugamushi developed by the Naval Medical Research Center. We used Bayesian LCMs to generate unbiased receiver operating characteristic curves and found that the sample dilution of 1:400 was optimal for the IgM ELISA. With the optimal cutoff OD of 1.474 at a sample dilution of 1:400, the IgM ELISA had a sensitivity of 85.7% (95% credible interval [CrI], 77.4% to 86.7%) and a specificity of 98.1% (95% CrI, 97.2% to 100%) using paired samples. For the ELISA, the OD could be determined objectively and quickly, in contrast to the reading of IFA slides, which was both subjective and labor-intensive. The IgM ELISA for scrub typhus has high diagnostic accuracy and is less subjective than the IgM IFA. We suggest that the IgM ELISA may be used as an alternative reference test to the IgM IFA for the serological diagnosis of scrub typhus. PMID:27008880

  1. Diagnostic accuracy of nucleic acid amplification based assays for tuberculous meningitis: A meta-analysis.

    PubMed

    Gupta, Renu; Talwar, Puneet; Talwar, Pumanshi; Khurana, Sarbjeet; Kushwaha, Suman; Jalan, Nupur; Thakur, Rajeev

    2018-05-25

    Numerous in-house and commercial nucleic acid amplification tests (NAAT) have been evaluated using variable reference standards for diagnosis of TBM but their diagnostic potential is still not very clear. We conducted a meta-analysis to assess the diagnostic accuracy of different NAAT based assays for diagnosing TBM against 43 data sets of confirmed TBM (n = 1066) and 61 data sets of suspected TBM (n = 3721) as two reference standards. The summary estimate of the sensitivity and the specificity were obtained using the bivariate model. QUADAS-2 tool was used to perform the Quality assessment for bias and applicability. Publication bias was assessed with Deeks' funnel plot. Studies with confirmed TBM had better summary estimates as compared to studies with clinically suspected TBM irrespective of NAAT and index tests used. Among in-house assays, MPB as the gene target had best summary estimates in both confirmed [sensitivity:90%(83-95), specificity:97-%(87-99), DOR:247 (50-1221), AUC:99%(97-100), PLR:38.8-(6.6-133), NLR:0.11(0.05-0.18), I 2   = 15%] and clinically suspected [sensitivity:69%(47-85), specificity:96%(90-98), DOR:62(16.8-232), AUC:94%(92-97), PLR:16.9(6.5-36.8), NLR:0.33(0.16-0.56), I 2 :15.3%] groups. GeneXpert revealed good diagnostic accuracy only in confirmed TBM group [sensitivity = 57%(38-74), specificity = 98%(89-100), DOR = 62(7-589), AUC = 87%(79-96), PLR = 33.2(3.8-128), NLR = 0.45(0.26-0.68), I 2   = 0%]. This meta-analysis identified potential role of MPB gene among in-house assays and GeneXpert as commercial assay for diagnosing TBM. Copyright © 2018. Published by Elsevier Ltd.

  2. Validation of a multiplex electrochemiluminescent immunoassay platform in human and mouse samples

    PubMed Central

    Bastarache, J.A.; Koyama, T.; Wickersham, N.E; Ware, L.B.

    2014-01-01

    Despite the widespread use of multiplex immunoassays, there are very few scientific reports that test the accuracy and reliability of a platform prior to publication of experimental data. Our laboratory has previously demonstrated the need for new assay platform validation prior to use of biologic samples from large studies in order to optimize sample handling and assay performance. In this study, our goal was to test the accuracy and reproducibility of an electrochemiluminescent multiplex immunoassay platform (Meso Scale Discovery, MSD®) and compare this platform to validated, singleplex immunoassays (R&D Systems®) using actual study subject (human plasma and mouse bronchoalveolar lavage fluid (BALF) and plasma) samples. We found that the MSD platform performed well on intra- and inter-assay comparisons, spike and recovery and cross-platform comparisons. The mean intra-assay CV% and range for MSD was 3.49 (0.0-10.4) for IL-6 and 2.04 (0.1-7.9) for IL-8. The correlation between values for identical samples measured on both MSD and R&D was R=0.97 for both analytes. The mouse MSD assay had a broader range of CV% with means ranging from 9.5-28.5 depending on the analyte. The range of mean CV% was similar for single plex ELISAs at 4.3-23.7 depending on the analyte. Regardless of species or sample type, CV% was more variable at lower protein concentrations. In conclusion, we validated a multiplex electrochemiluminscent assay system and found that it has superior test characteristics in human plasma compared to mouse BALF and plasma. Both human and MSD assays compared favorably to well-validated singleplex ELISA's PMID:24768796

  3. Liquid chromatography/tandem mass spectrometry method for simultaneous determination of cocaine and its metabolite (-)ecgonine methyl ester in human acidified stabilized plasma samples.

    PubMed

    Liu, Yongzhen; Zheng, Bo; Strafford, Stephanie; Orugunty, Ravi; Sullivan, Michael; Gus, Jeffrey; Heidbreder, Christian; Fudala, Paul J; Nasser, Azmi

    2014-06-15

    Two simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) methods (low range and high range) were developed and validated for the quantification of cocaine and its metabolite (-)ecgonine methyl ester (EME) in human acidified stabilized plasma samples. In the low range assay, cocaine and the internal standard, cocaine-D3, were extracted using a single step liquid-liquid extraction from human acidified stabilized plasma. For the high range assay, human acidified stabilized plasma containing cocaine, EME, and the internal standards, cocaine-D3 and EME-D3, was mixed with acetonitrile, and the protein precipitate was separated by centrifugation. Both cocaine and EME extracted from both assays were separated on a HILIC column and detected in positive ion mode using multiple reaction monitoring (MRM). Both methods were validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The linear range for the low range assay was 0.01-5ng/mL for cocaine; in the high range assay values were 5-1000ng/mL for cocaine and 1-200ng/mL for EME. The correlation coefficient (R(2)) values for both assays were 0.993 or greater. The precision and accuracy for intra-day and inter-day were better than 13.0%. The recovery was above 85% and matrix effects were low with the matrix factor ranging from 0.817 to 1.10 for both analytes in both assays. The validated methods were successfully used to quantify the plasma concentrations of cocaine and EME in clinical pharmacokinetic and pharmacodynamic studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Modification of a deoxynivalenol-antigen-mimicking nanobody to improve immunoassay sensitivity by site-saturation mutagenesis.

    PubMed

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Wang, Wei; Liu, Yuan-Yuan

    2016-01-01

    A nanobody (N-28) which can act as a deoxynivalenol (DON) antigen has been generated, and its residues Thr102-Ser106 were identified to bind with anti-DON monoclonal antibody by alanine-scanning mutagenesis. Site-saturation mutagenesis was used to analyze the plasticity of five residues and to improve the sensitivity of the N-28-based immunoassay. After mutagenesis, three mutants were selected by phage immunoassay and were sequenced. The half-maximal inhibitory concentrations of the immunoassay based on mutants N-28-T102Y, N-28-V103L, and N-28-Y105F were 24.49 ± 1.0, 51.83 ± 2.5, and 35.65 ± 1.6 ng/mL, respectively, showing the assay was, respectively, 3.2, 1.5, and 2.2 times more sensitive than the wild-type-based assay. The best mutant, N-28-T102Y, was used to develop a competitive phage ELISA to detect DON in cereals with high specificity and accuracy. In addition, the structural properties of N-28-T102Y and N-28 were investigated, revealing that the affinity of N-28-T102Y decreased because of increased steric hindrance with the large side chain. The lower-binding-affinity antigen mimetic may contribute to the improvement of the sensitivity of competitive immunoassays. These results demonstrate that nanobodies would be a favorable tool for engineering. Moreover, our results have laid a solid foundation for site-saturation mutagenesis of antigen-mimicking nanobodies to improve immunoassay sensitivity for small molecules.

  5. Application of upconversion luminescent-magnetic microbeads with weak background noise and facile separation in ochratoxin A detection

    NASA Astrophysics Data System (ADS)

    Liao, Zhenyu; Zhang, Ying; Su, Lin; Chang, Jin; Wang, Hanjie

    2017-02-01

    Ochratoxin A (OTA), the most harmful and abundant ochratoxin, is chemically stable and commonly existed in foodstuffs. In this work, upconversion luminescent-magnetic microbeads (UCLMMs) -based cytometric bead array for OTA detection with a less reagent consumption and high sensitivity has been established and optimized. In UCLMMs, upconversion nanocrystals (UCNs) for optical code present a weak background noise and no spectral cross talk between the encoding signals and target labels under two excitation conditions to improve detection sensitivity. While the superparamagnetic Fe3O4 nanoparticles (Fe3O4 NPs) aim for rapid analysis. The results show that the developed method has a sensitivity of 9.553 ppt below HPLC with a 50-μL sample and can be completed in <2 h with good accuracy and high reproducibility. Therefore, different colors of UCLMMs will become a promising assay platform for multiple mycotoxins after further improvement.

  6. Improved regulatory element prediction based on tissue-specific local epigenomic signatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Yupeng; Gorkin, David U.; Dickel, Diane E.

    Accurate enhancer identification is critical for understanding the spatiotemporal transcriptional regulation during development as well as the functional impact of disease-related noncoding genetic variants. Computational methods have been developed to predict the genomic locations of active enhancers based on histone modifications, but the accuracy and resolution of these methods remain limited. Here, we present an algorithm, regulator y element prediction based on tissue-specific local epigenetic marks (REPTILE), which integrates histone modification and whole-genome cytosine DNA methylation profiles to identify the precise location of enhancers. We tested the ability of REPTILE to identify enhancers previously validated in reporter assays. Compared withmore » existing methods, REPTILE shows consistently superior performance across diverse cell and tissue types, and the enhancer locations are significantly more refined. We show that, by incorporating base-resolution methylation data, REPTILE greatly improves upon current methods for annotation of enhancers across a variety of cell and tissue types.« less

  7. Improved regulatory element prediction based on tissue-specific local epigenomic signatures

    DOE PAGES

    He, Yupeng; Gorkin, David U.; Dickel, Diane E.; ...

    2017-02-13

    Accurate enhancer identification is critical for understanding the spatiotemporal transcriptional regulation during development as well as the functional impact of disease-related noncoding genetic variants. Computational methods have been developed to predict the genomic locations of active enhancers based on histone modifications, but the accuracy and resolution of these methods remain limited. Here, we present an algorithm, regulator y element prediction based on tissue-specific local epigenetic marks (REPTILE), which integrates histone modification and whole-genome cytosine DNA methylation profiles to identify the precise location of enhancers. We tested the ability of REPTILE to identify enhancers previously validated in reporter assays. Compared withmore » existing methods, REPTILE shows consistently superior performance across diverse cell and tissue types, and the enhancer locations are significantly more refined. We show that, by incorporating base-resolution methylation data, REPTILE greatly improves upon current methods for annotation of enhancers across a variety of cell and tissue types.« less

  8. Performance of the Xpert MTB/RIF assay in the diagnosis of tuberculosis in formalin-fixed, paraffin-embedded tissues.

    PubMed

    Polepole, Pascal; Kabwe, Mwila; Kasonde, Mpanga; Tembo, John; Shibemba, Aaron; O'Grady, Justin; Kapata, Nathan; Zumla, Alimuddin; Bates, Matthew

    2017-01-01

    Extrapulmonary tuberculosis (EPTB), which accounts for 10%-40% of the global burden of TB, with the highest incidence in Sub-Saharan Africa, is strongly associated with human immunodeficiency virus infection. Diagnosing EPTB is challenging, and recently, there has been a concerted effort to evaluate the latest molecular diagnostics for diagnosing TB in a range of specimen types. The Xpert MTB/RIF assay (Cepheid, Sunnyvale, CA, USA) is one such technology, which simultaneously detects Mycobacterium tuberculosis and rifampicin resistance. Our objective was to evaluate the accuracy of the Xpert MTB/RIF assay for the diagnosis of EPTB and detection of rifampicin resistance in routinely processed formalin-fixed, paraffin-embedded (FFPE) tissues, compared with histological detection of TB as the gold standard. A convenience set of 100 biobanked FFPE tissues, including lymph nodes (n = 64), male genital tract tissue (n = 10), abdominal tissue (n = 8), female genital tissue (n = 5), breast tissue (n = 5), synovial tissue (n = 4), skin (n = 2), tongue tissue (n = 1), and thyroid (n = 1), from routine cases of clinically suspected EPTB admitted to the University Teaching Hospital, Lusaka, Zambia, were analyzed using the Xpert MTB/RIF assay and in-house polymerase chain reaction (PCR) assay targeting IS6110, in parallel with Ziehl-Neelsen (ZN) staining, against histology as the gold standard. Some 66% of specimens had histological evidence of TB infection. ZN staining was positive for TB in 8% of cases, and Xpert MTB/RIF was positive for TB in 25% of cases. Taking histology as the gold standard, the sensitivity and specificity were as follows: In lymph tissue the accuracy of the Xpert MTB/RIF assay was 41% (95%CI 27-57), not significantly better than ZN or the in-house PCR assay. In non-lymph tissue the sensitivity of the in-house PCR assay was 82% (95%CI: 56%-95%), significantly higher than the Xpert MTB/RIF assay (P = 0.004). The Xpert MTB/RIF assay indicated rifampicin resistance in just three cases. The Xpert MTB/RIF assay is potentially a useful tool for the diagnosis of TB in routine FFPE tissues.

  9. Evaluation of a broad-ranging and convenient enzyme-linked immunosorbent assay using the lysate of infected cells with five serotypes of Orientia tsutsugamushi, a causative agent of scrub typhus.

    PubMed

    Ogawa, Motohiko; Satoh, Masaaki; Saijo, Masayuki; Ando, Shuji

    2017-01-05

    Scrub typhus is a mite-borne rickettsiosis caused by infection of Orientia tsutsugamushi, which is endemic to several Asia-Pacific Rim countries, including Japan. Although micro-indirect immunofluorescent assay (micro-IFA) is the standard method for the serological diagnosis of scrub typhus, enzyme-linked immunosorbent assay (ELISA) is considered to be more objective, by providing digitized results as opposed to being subject to the judgment of the evaluator as in micro-IFA. Therefore, the aim of this study was to develop a broad-ranging ELISA using the five major prevalent serotypes of O. tsutsugamushi in Japan as the antigens. Furthermore, in contrast to previous studies that used purified microorganisms via ultracentrifugation, we directly used the infected cells, and evaluated the diagnostic accuracy of this simplified method to that of micro-IFA. Evaluation of paired patient sera against the five serotypes showed that the accuracy of ELISA relative to micro-IFA was 87.4 and 79.5% for immunoglobulin (Ig)M and IgG assays, respectively, at the optimized cut-off value. Further evaluation of patient sera against the expected serotype of the infecting strain showed that the accuracy of ELISA compared to micro-IFA increased to 100 and 97.4% in the IgM and IgG assays, respectively. This suggests that use of the five prevalent serotypes contributed to the increase of the accuracy of ELISA. When applying the criteria of serological diagnosis for paired sera samples to ELISA, all 19 patients were diagnosed as positive; a ≥4-fold elevation of the antibody titer was observed in 15 of 19 patients that were positive, and very high antibody titers were observed in both paired sera samples of the remaining four patients. In addition, all samples of healthy subjects and patients with other types of rickettsiosis were diagnosed as negative using these criteria. Our results suggest the excellent performance of the new broad-ranging and convenient ELISA, which appears to be applicable for the diagnosis of scrub typhus patients infected with the wide variety of prevalent strains in Japan. Furthermore, the ELISA is more objective than the micro-IFA, and can therefore provide more accurate diagnoses in Japan.

  10. Analytical validation of a novel multiplex test for detection of advanced adenoma and colorectal cancer in symptomatic patients.

    PubMed

    Dillon, Roslyn; Croner, Lisa J; Bucci, John; Kairs, Stefanie N; You, Jia; Beasley, Sharon; Blimline, Mark; Carino, Rochele B; Chan, Vicky C; Cuevas, Danissa; Diggs, Jeff; Jennings, Megan; Levy, Jacob; Mina, Ginger; Yee, Alvin; Wilcox, Bruce

    2018-05-30

    Early detection of colorectal cancer (CRC) is key to reducing associated mortality. Despite the importance of early detection, approximately 40% of individuals in the United States between the ages of 50-75 have never been screened for CRC. The low compliance with colonoscopy and fecal-based screening may be addressed with a non-invasive alternative such as a blood-based test. We describe here the analytical validation of a multiplexed blood-based assay that measures the plasma concentrations of 15 proteins to assess advanced adenoma (AA) and CRC risk in symptomatic patients. The test was developed on an electrochemiluminescent immunoassay platform employing four multi-marker panels, to be implemented in the clinic as a laboratory developed test (LDT). Under the Clinical Laboratory Improvement Amendments (CLIA) and College of American Pathologists (CAP) regulations, a United States-based clinical laboratory utilizing an LDT must establish performance characteristics relating to analytical validity prior to releasing patient test results. This report describes a series of studies demonstrating the precision, accuracy, analytical sensitivity, and analytical specificity for each of the 15 assays, as required by CLIA/CAP. In addition, the report describes studies characterizing each of the assays' dynamic range, parallelism, tolerance to common interfering substances, spike recovery, and stability to sample freeze-thaw cycles. Upon completion of the analytical characterization, a clinical accuracy study was performed to evaluate concordance of AA and CRC classifier model calls using the analytical method intended for use in the clinic. Of 434 symptomatic patient samples tested, the percent agreement with original CRC and AA calls was 87% and 92% respectively. All studies followed CLSI guidelines and met the regulatory requirements for implementation of a new LDT. The results provide the analytical evidence to support the implementation of the novel multi-marker test as a clinical test for evaluating CRC and AA risk in symptomatic individuals. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Validation of Clinical Testing for Warfarin Sensitivity

    PubMed Central

    Langley, Michael R.; Booker, Jessica K.; Evans, James P.; McLeod, Howard L.; Weck, Karen E.

    2009-01-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 −1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses. PMID:19324988

  12. Modeling error in experimental assays using the bootstrap principle: Understanding discrepancies between assays using different dispensing technologies

    PubMed Central

    Hanson, Sonya M.; Ekins, Sean; Chodera, John D.

    2015-01-01

    All experimental assay data contains error, but the magnitude, type, and primary origin of this error is often not obvious. Here, we describe a simple set of assay modeling techniques based on the bootstrap principle that allow sources of error and bias to be simulated and propagated into assay results. We demonstrate how deceptively simple operations—such as the creation of a dilution series with a robotic liquid handler—can significantly amplify imprecision and even contribute substantially to bias. To illustrate these techniques, we review an example of how the choice of dispensing technology can impact assay measurements, and show how large contributions to discrepancies between assays can be easily understood and potentially corrected for. These simple modeling techniques—illustrated with an accompanying IPython notebook—can allow modelers to understand the expected error and bias in experimental datasets, and even help experimentalists design assays to more effectively reach accuracy and imprecision goals. PMID:26678597

  13. Development of real-time PCR assays for the detection of Moraxella macacae associated with bloody nose syndrome in rhesus (Macaca mulatta) and cynomolgus (Macaca fascicularis) macaques

    PubMed Central

    Whitehouse, Chris A.; Chase, Kitty; Embers, Monica E.; Kulesh, David A.; Ladner, Jason T.; Palacios, Gustavo F.; Minogue, Timothy D.

    2016-01-01

    Background Moraxella macacae is a recently described bacterial pathogen that causes epistaxis or so-called bloody nose syndrome in captive macaques. The aim of this study was to develop specific molecular diagnostic assays for M. macacae and to determine their performance characteristics. Methods We developed six real-time PCR assays on the Roche LightCycler. The accuracy, precision, selectivity, and limit of detection (LOD) were determined for each assay, in addition to further validation by testing nasal swabs from macaques presenting with epistaxis at the Tulane National Primate Research Center. Results All assays exhibited 100% specificity and were highly sensitive with an LOD of 10 fg for chromosomal assays and 1 fg for the plasmid assay. Testing of nasal swabs from 10 symptomatic macaques confirmed the presence of M. macacae in these animals. Conclusions We developed several accurate, sensitive, and species-specific real-time PCR assays for the detection of M. macacae in captive macaques. PMID:26365904

  14. Validation and comparison of two NGS assays for the detection of EGFR T790M resistance mutation in liquid biopsies of NSCLC patients.

    PubMed

    Vollbrecht, Claudia; Lehmann, Annika; Lenze, Dido; Hummel, Michael

    2018-04-06

    Analysis of circulating cell-free DNA (cfDNA) derived from peripheral blood ("liquid biopsy") is an attractive alternative to identify non-small cell lung cancer (NSCLC) patients with the EGFR T790M mutation eligible for 3rd generation tyrosine kinase inhibitor therapy. We evaluated two PCR-based next generation sequencing (NGS) approaches, one including unique molecular identifiers (UMI), with focus on highly sensitive EGFR T790M mutation detection. Therefore, we extracted and sequenced cfDNA from synthetic plasma samples spiked with mutated DNA at decreasing allele frequencies and from 21 diagnostic NSCLC patients. Data evaluation was performed to determine the limit of detection (LoD), accuracy, specificity and sensitivity of both assays. Considering all tested reference dilutions and mutations the UMI assay performed best in terms of LoD (1% vs. 5%), sensitivity (95.8% vs. 81.3%), specificity (100% vs. 93.8%) and accuracy (96.9% vs. 84.4%). Comparing mutation status of diagnostic samples with both assays showed 81.3% concordance with primary mutation verifiable in 52% of cases. EGFR T790M was detected concordantly in 6/7 patients with allele frequencies from 0.1% to 27%. In one patient, the T790M mutation was exclusively detectable with the UMI assay. Our data demonstrate that both assays are applicable as multi-biomarker NGS tools enabling the simultaneous detection of primary EGFR driver and resistance mutations. However, for mutations with low allelic frequencies the use of NGS panels with UMI facilitates a more sensitive and reliable detection.

  15. Validation and comparison of two NGS assays for the detection of EGFR T790M resistance mutation in liquid biopsies of NSCLC patients

    PubMed Central

    Vollbrecht, Claudia; Lehmann, Annika; Lenze, Dido; Hummel, Michael

    2018-01-01

    Analysis of circulating cell-free DNA (cfDNA) derived from peripheral blood (“liquid biopsy”) is an attractive alternative to identify non-small cell lung cancer (NSCLC) patients with the EGFR T790M mutation eligible for 3rd generation tyrosine kinase inhibitor therapy. We evaluated two PCR-based next generation sequencing (NGS) approaches, one including unique molecular identifiers (UMI), with focus on highly sensitive EGFR T790M mutation detection. Therefore, we extracted and sequenced cfDNA from synthetic plasma samples spiked with mutated DNA at decreasing allele frequencies and from 21 diagnostic NSCLC patients. Data evaluation was performed to determine the limit of detection (LoD), accuracy, specificity and sensitivity of both assays. Considering all tested reference dilutions and mutations the UMI assay performed best in terms of LoD (1% vs. 5%), sensitivity (95.8% vs. 81.3%), specificity (100% vs. 93.8%) and accuracy (96.9% vs. 84.4%). Comparing mutation status of diagnostic samples with both assays showed 81.3% concordance with primary mutation verifiable in 52% of cases. EGFR T790M was detected concordantly in 6/7 patients with allele frequencies from 0.1% to 27%. In one patient, the T790M mutation was exclusively detectable with the UMI assay. Our data demonstrate that both assays are applicable as multi-biomarker NGS tools enabling the simultaneous detection of primary EGFR driver and resistance mutations. However, for mutations with low allelic frequencies the use of NGS panels with UMI facilitates a more sensitive and reliable detection. PMID:29719623

  16. Comparison of two assays for detection of antibodies against canine parvovirus and canine distemper virus in dogs admitted to a Florida animal shelter.

    PubMed

    Gray, Lauren K; Crawford, P Cynda; Levy, Julie K; Dubovi, Edward J

    2012-05-01

    To compare 2 assays for use in the identification of dogs with a protective antibody titer (PAT) against canine parvovirus (CPV) and canine distemper virus (CDV). Prospective cross-sectional study. 431 dogs admitted to a municipal animal shelter in north central Florida. Blood samples were collected from dogs on the day of admission to the shelter. Serum was obtained, criterion-referenced assays were used to identify dogs that had PATs against CPV (titers ≥ 80; hemagglutination inhibition assay) and CDV (titers ≥ 32; virus neutralization assay), and results were compared with results of a semiquantitative ELISA and an immunofluorescence assay (IFA). For correct identification of dogs that had PATs against viruses, the ELISA had significantly higher specificity for CPV (98%) and CDV (95%) than did the IFA (82% and 70%, respectively) and had significantly lower sensitivity for CDV (88%) than did the IFA (97%); the sensitivity for CPV was similar (ELISA, 98%; IFA, 97%). Overall diagnostic accuracy was significantly greater with the ELISA than with the IFA. Predictive value of a positive result for PATs was significantly higher with the ELISA for CPV (99%) and CDV (93%) than with the IFA (92% and 71%, respectively). The ELISA had fewer false-positive results than did the IFA and could be performed on-site in shelters in < 1 hour. Accuracy and practicality of the ELISA may be useful for identifying the infection risk of dogs exposed during outbreaks attributable to CPV and CDV infections in shelters.

  17. Genetic Assay for Transcription Errors: Methods to Monitor Treatments or Chemicals that Increase the Error Rate of RNA synthesis | NCI Technology Transfer Center | TTC

    Cancer.gov

    Researchers at the National Cancer Institute (NCI) developed a genetic assay for detecting transcription errors in RNA synthesis. This new assay extends the familiar concept of an Ames test which monitors DNA damage and synthesis errors to the previously inaccessible issue of RNA synthesis fidelity. The FDA requires genetic DNA focused tests for all drug approval as it assesses the in vivo mutagenic and carcinogenic potential of a drug. The new assay will open an approach to monitoring the impact of treatments on the accuracy of RNA synthesis. Errors in transcription have been hypothesized to be a component of aging and age-related diseases. The National Cancer Institute (NCI) seeks licensing partners for the genetic assay.

  18. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique.

    PubMed Central

    Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen

    2006-01-01

    OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726

  19. Novel rapid molecular diagnosis of fetal chromosomal abnormalities associated with recurrent pregnancy loss.

    PubMed

    Yang, Lan; Tang, Ye; Lu, Mudan; Yang, Yuefen; Xiao, Jianping; Wang, Qiaoxia; Yang, Canfeng; Tao, Hehua; Xiang, Jingying

    2016-12-01

    Labor-intensive karyotyping is used as the reference standard diagnostic test to identify copy number variants (CNVs) in the fetal genome after recurrent pregnancy loss. Our aim was to present and evaluate a novel molecular assay called CNVplex that could potentially be used as an alternative method to conventional karyotyping for diagnosing fetal chromosomal abnormalities associated with recurrent pregnancy loss. Using karyotyping as the reference standard, CNVplex was performed to identify fetal chromosomal abnormalities in the chorionic villus samples from 76 women experiencing at least two pregnancy losses. Its diagnostic accuracy, sensitivity, and specificity were evaluated to detect aneuploidies associated with recurrent pregnancy loss. Turnaround time and costs of CNVplex were also measured. Diagnostic accuracy of CNVplex in aneuploidies that are associated with recurrent pregnancy loss was 1.0 (95% CI 0.94-1.0), sensitivity was 100% (95% CI 0.89-1.0), and specificity was 100% (95% CI 0.875-1.0). Diagnostic accuracy of CNVplex was similar to that of karyotyping. Both karyotyping and CNVplex assay detected 27 autosomal trisomies, three 45,X monosomies, and three polyploidies. CNVplex also detected additional novel structural abnormalities of the fetal genome. Compared with karyotyping, CNVplex significantly (p = 0.001) reduced the waiting time by 13.98 days (95% CI 13.88-14.08) and the cost by US $241 (95% CI 234.53-247.47). CNVplex is a novel effective assay for diagnosing fetal chromosomal abnormalities associated with recurrent pregnancy loss. In the routine clinical work-up of recurrent pregnancy loss, diagnostic accuracy of CNVplex is comparable to that of conventional karyotyping but it requires less waiting time and has lower cost. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  20. Capillary zone electrophoresis method for a highly glycosylated and sialylated recombinant protein: development, characterization and application for process development.

    PubMed

    Zhang, Le; Lawson, Ken; Yeung, Bernice; Wypych, Jette

    2015-01-06

    A purity method based on capillary zone electrophoresis (CZE) has been developed for the separation of isoforms of a highly glycosylated protein. The separation was found to be driven by the number of sialic acids attached to each isoform. The method has been characterized using orthogonal assays and shown to have excellent specificity, precision and accuracy. We have demonstrated the CZE method is a useful in-process assay to support cell culture and purification development of this glycoprotein. Compared to isoelectric focusing (IEF), the CZE method provides more quantitative results and higher sample throughput with excellent accuracy, qualities that are required for process development. In addition, the CZE method has been applied in the stability testing of purified glycoprotein samples.

  1. Rapid and quantitative detection of zoonotic influenza A virus infection utilizing coumarin-derived dendrimer-based fluorescent immunochromatographic strip test (FICT).

    PubMed

    Yeo, Seon-Ju; Huong, Dinh Thi; Hong, Nguyen Ngoc; Li, Chun-Ying; Choi, Kyunghan; Yu, Kyoungsik; Choi, Du-Young; Chong, Chom-Kyu; Choi, Hak Soo; Mallik, Shyam Kumar; Kim, Hak Sung; Sung, Haan Woo; Park, Hyun

    2014-01-01

    Great efforts have been made to develop robust signal-generating fluorescence materials which will help in improving the rapid diagnostic test (RDT) in terms of sensitivity and quantification. In this study, we developed coumarin-derived dendrimer-based fluorescent immunochromatographic strip test (FICT) assay with enhanced sensitivity as a quantitative diagnostic tool in typical RDT environments. The accuracy of the proposed FICT was compared with that of dot blot immunoassay techniques and conventional RDTs. Through conjugation of coumarin-derived dendrimers with latex beads, fluorescent emission covering broad output spectral ranges was obtained which provided a distinct advantage of easy discrimination of the fluorescent emission of the latex beads with a simple insertion of a long-pass optical filter away from the excitation wavelength. The newly developed FICT assay was able to detect 100 ng/10 μL of influenza A nucleoprotein (NP) antigen within 5 minutes, which corresponded to 2.5-fold higher sensitivity than that of the dot blot immunoassay or conventional RDTs. Moreover, the FICT assay was confirmed to detect at least four avian influenza A subtypes (H5N3, H7N1, H7N7, and H9N2). On applying the FICT to the clinical swab samples infected with respiratory viruses, our FICT assay was confirmed to differentiate influenza H1N1 infection from other respiratory viral diseases. These data demonstrate that the proposed FICT assay is able to detect zoonotic influenza A viruses with a high sensitivity, and it enables the quantitation of the infection intensity by providing the numerical diagnostic values; thus demonstrating enhanced detectability of influenza A viruses.

  2. An impedimetric micro-immunosensing assay to detect Alzheimer's disease biomarker: Aβ40.

    PubMed

    Zakaria, Norazreen; Ramli, Muhammad Zaki; Ramasamy, Kalavathy; Meng, Lim Siong; Yean, Chan Yean; Banga Singh, Kirnpal Kaur; Zain, Zainiharyati Mohd; Low, Kim-Fatt

    2018-06-04

    A miniaturized biosensing platform, based on monoclonal amyloid-beta antibodies (mAβ ab ) that were immobilized on a disc-shaped platinum/iridium (Pt/Ir) microelectrode surface coupled with an impedimetric signal transducer, was developed for the label-free and sensitive detection of amyloid-beta peptide fragment 1-40 (Aβ40); a reliable biomarker for early diagnosis of Alzheimer's disease (AD). A Pt/Ir microelectrode was electropolymerized with poly (ortho-phenylenediamine), a conducting free amine-containing aromatic polymer; followed by crosslinking with glutaraldehyde for subsequent coupling of mAβ ab on the microelectrode surface. This modification strategy efficiently improved the impedimetric detection performance of Aβ40 in terms of charge transfer resistance (∼400-fold difference) and normalized impedance magnitude percentage change (∼40% increase) compared with a passive adsorption-based immobilization method. The sensitivity of the micro-immunosensing assay was found to be 1056 kΩ/(pg/mL)/cm 2 and the limit of detection was found to be 4.81 pg/mL with a dynamic range of 1-10 4  pg/mL (R 2  = 0.9932). The overall precision of the assay, as measured by relative standard deviation, ranged from 0.84 to 5.15%, demonstrating its reliability and accuracy; while in respect to assay durability and stability, the immobilized mAβ ab were able to maintain 80% of their binding activity to Aβ40 after incubation for 48 h at ambient temperature (25 °C). To validate the practical applicability, the assay was tested using brain tissue lysates prepared from AD-induced rats. Results indicate that the proposed impedimetric micro-immunosensing platform is highly versatile and adaptable for the quantitative detection of other disease-related biomarkers. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Development of single-step multiplex real-time RT-PCR assays for rapid diagnosis of enterovirus 71, coxsackievirus A6, and A16 in patients with hand, foot, and mouth disease.

    PubMed

    Puenpa, Jiratchaya; Suwannakarn, Kamol; Chansaenroj, Jira; Vongpunsawad, Sompong; Poovorawan, Yong

    2017-10-01

    Real-time reverse-transcription polymerase chain reaction (rRT-PCR) to detect enterovirus 71 (EV-A71) and coxsackievirus A16 (CV-A16) has facilitated the rapid and accurate identification of the two most common etiological agents underlying hand, foot, and mouth disease (HFMD). However, the worldwide emergence of CV-A6 infection in HFMD necessitates development of an improved multiplex rRT-PCR method. To rapidly determine the etiology of HFMD, two rRT-PCR assays using TaqMan probes were developed to differentiate among three selected common enteroviruses (EV-A71, CV-A16 and CV-A6) and to enable broad detection of enteroviruses (pan-enterovirus assay). No cross-reactions were observed with other RNA viruses examined. The detection limits of both assays were 10 copies per microliter for EV-A71, CV-A6 and CV-A16, and pan-enterovirus. The methods showed high accuracy (EV-A71, 90.6%; CV-A6, 92.0%; CV-A16, 100%), sensitivity (EV-A71, 96.5%; CV-A6, 95.8%; CV-A16, 99.0%), and specificity (EV-A71, 100%; CV-A6, 99.9%; CV-A16, 99.9%) in testing clinical specimens (n=1049) during 2014-2016, superior to those of conventional RT-PCR. Overall, the multiplex rRT-PCR assays enabled highly sensitive detection and rapid simultaneous typing of EV-A71, CV-A6 and CV-A16, and enteroviruses, rendering them feasible and attractive methods for large-scale surveillance of enteroviruses associated with HFMD outbreaks. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Comparison of an In Vitro Diagnostic Next-Generation Sequencing Assay with Sanger Sequencing for HIV-1 Genotypic Resistance Testing.

    PubMed

    Tzou, Philip L; Ariyaratne, Pramila; Varghese, Vici; Lee, Charlie; Rakhmanaliev, Elian; Villy, Carolin; Yee, Meiqi; Tan, Kevin; Michel, Gerd; Pinsky, Benjamin A; Shafer, Robert W

    2018-06-01

    The ability of next-generation sequencing (NGS) technologies to detect low frequency HIV-1 drug resistance mutations (DRMs) not detected by dideoxynucleotide Sanger sequencing has potential advantages for improved patient outcomes. We compared the performance of an in vitro diagnostic (IVD) NGS assay, the Sentosa SQ HIV genotyping assay for HIV-1 genotypic resistance testing, with Sanger sequencing on 138 protease/reverse transcriptase (RT) and 39 integrase sequences. The NGS assay used a 5% threshold for reporting low-frequency variants. The level of complete plus partial nucleotide sequence concordance between Sanger sequencing and NGS was 99.9%. Among the 138 protease/RT sequences, a mean of 6.4 DRMs was identified by both Sanger and NGS, a mean of 0.5 DRM was detected by NGS alone, and a mean of 0.1 DRM was detected by Sanger sequencing alone. Among the 39 integrase sequences, a mean of 1.6 DRMs was detected by both Sanger sequencing and NGS and a mean of 0.15 DRM was detected by NGS alone. Compared with Sanger sequencing, NGS estimated higher levels of resistance to one or more antiretroviral drugs for 18.2% of protease/RT sequences and 5.1% of integrase sequences. There was little evidence for technical artifacts in the NGS sequences, but the G-to-A hypermutation was detected in three samples. In conclusion, the IVD NGS assay evaluated in this study was highly concordant with Sanger sequencing. At the 5% threshold for reporting minority variants, NGS appeared to attain a modestly increased sensitivity for detecting low-frequency DRMs without compromising sequence accuracy. Copyright © 2018 American Society for Microbiology.

  5. Development and evaluation of a simple and effective RT-qPCR inhibitory assay for detection of the efficacy of compounds towards HIV reverse transcriptase.

    PubMed

    Marino-Merlo, Francesca; Frezza, Caterina; Papaianni, Emanuela; Valletta, Elena; Mastino, Antonio; Macchi, Beatrice

    2017-11-01

    Assessing the actual efficacy of compounds to directly inhibit HIV reverse transcriptase (RT) activity is a main goal in preclinical antiretroviral studies. Our previous studies demonstrated that the effects of inhibitor compounds towards HIV-RT could be efficiently assessed through a simple cell-free assay based on conventional reverse transcription PCR. In the present study, we describe a modified variant of our assay, termed RT real-time quantitative PCR inhibitory assay (RT-qPCR-IA), in which the ability of compounds to restrict the complementary DNA (cDNA) generation by HIV-RT using a specific RNA template is performed by the real-time technique, in order to improve both accuracy and sensitivity of the method. As specific RNA template, RNA extracted from stable transfectants ectopically expressing the herpes simplex virus 1 glycoprotein D gene was utilized. HIV-RT, of both commercial or house-made viral lysate origin, was employed for the assay. To assess the reliability of RT-qPCR-IA, we performed a comparative, quantitative analysis of the dose-dependent effect exerted by known nucleotide and non-nucleotide reverse-transcriptase inhibitors, using the SYBR Green dye chemistry as detection system. The results obtained with RT-qPCR-IA were compared to that obtained using a one-step PicoGreen technology-based commercial kit. The outcome of our study indicates that the development of the novel RT-qPCR-IA will provide rapid and accurate evaluation of the inhibitory efficacy of compounds towards HIV-RT activity. This evaluation could be very useful for large-scale screening of potential new anti-HIV drugs.

  6. Assay of fluoxetine hydrochloride by titrimetric and HPLC methods.

    PubMed

    Bueno, F; Bergold, A M; Fröehlich, P E

    2000-01-01

    Two alternative methods were proposed to assay Fluoxetine Hydrochloride: a titrimetric method and another by HPLC using as mobile phase water pH 3.5: acetonitrile (65:35). These methods were applied to the determination of Fluoxetine as such or in formulations (capsules). The titrimetric method is an alternative for pharmacies and small industries. Both methods showed accuracy and precision and are an alternative to the official methods.

  7. Highly accurate detection of ovarian cancer using CA125 but limited improvement with serum matrix-assisted laser desorption/ionization time-of-flight mass spectrometry profiling.

    PubMed

    Tiss, Ali; Timms, John F; Smith, Celia; Devetyarov, Dmitry; Gentry-Maharaj, Aleksandra; Camuzeaux, Stephane; Burford, Brian; Nouretdinov, Ilia; Ford, Jeremy; Luo, Zhiyuan; Jacobs, Ian; Menon, Usha; Gammerman, Alex; Cramer, Rainer

    2010-12-01

    Our objective was to test the performance of CA125 in classifying serum samples from a cohort of malignant and benign ovarian cancers and age-matched healthy controls and to assess whether combining information from matrix-assisted laser desorption/ionization (MALDI) time-of-flight profiling could improve diagnostic performance. Serum samples from women with ovarian neoplasms and healthy volunteers were subjected to CA125 assay and MALDI time-of-flight mass spectrometry (MS) profiling. Models were built from training data sets using discriminatory MALDI MS peaks in combination with CA125 values and tested their ability to classify blinded test samples. These were compared with models using CA125 threshold levels from 193 patients with ovarian cancer, 290 with benign neoplasm, and 2236 postmenopausal healthy controls. Using a CA125 cutoff of 30 U/mL, an overall sensitivity of 94.8% (96.6% specificity) was obtained when comparing malignancies versus healthy postmenopausal controls, whereas a cutoff of 65 U/mL provided a sensitivity of 83.9% (99.6% specificity). High classification accuracies were obtained for early-stage cancers (93.5% sensitivity). Reasons for high accuracies include recruitment bias, restriction to postmenopausal women, and inclusion of only primary invasive epithelial ovarian cancer cases. The combination of MS profiling information with CA125 did not significantly improve the specificity/accuracy compared with classifications on the basis of CA125 alone. We report unexpectedly good performance of serum CA125 using threshold classification in discriminating healthy controls and women with benign masses from those with invasive ovarian cancer. This highlights the dependence of diagnostic tests on the characteristics of the study population and the crucial need for authors to provide sufficient relevant details to allow comparison. Our study also shows that MS profiling information adds little to diagnostic accuracy. This finding is in contrast with other reports and shows the limitations of serum MS profiling for biomarker discovery and as a diagnostic tool.

  8. Residual bovine serum albumin (BSA) quantitation in vaccines using automated Capillary Western technology.

    PubMed

    Loughney, John W; Lancaster, Catherine; Ha, Sha; Rustandi, Richard R

    2014-09-15

    Bovine serum albumin (BSA) is a major component of fetal bovine serum (FBS), which is commonly used as a culture medium during vaccine production. Because BSA can cause allergic reactions in humans the World Health Organization (WHO) has set a guidance of 50 ng or less residual BSA per vaccine dose. Vaccine manufacturers are expected to develop sensitive assays to detect residual BSA. Generally, sandwich enzyme-linked immunosorbent assays (ELISA) are used in the industry to detect these low levels of BSA. We report the development of a new improved method for residual BSA detection using the SimpleWestern technology to analyze residual BSA in an attenuated virus vaccine. The method is based on automated Capillary Western and has linearity of two logs, >80% spike recovery (accuracy), intermediate precision of CV <15%, and LOQ of 5.2 ng/ml. The final method was applied to analyze BSA in four lots of bulk vaccine products and was used to monitor BSA clearance during vaccine process purification. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. False HDAC Inhibition by Aurone Compound.

    PubMed

    Itoh, Yukihiro; Suzuki, Miki; Matsui, Taiji; Ota, Yosuke; Hui, Zi; Tsubaki, Kazunori; Suzuki, Takayoshi

    2016-01-01

    Fluorescence assays are useful tools for estimating enzymatic activity. Their simplicity and manageability make them suitable for screening enzyme inhibitors in drug discovery studies. However, researchers need to pay attention to compounds that show auto-fluorescence and quench fluorescence, because such compounds lower the accuracy of the fluorescence assay systems by producing false-positive or negative results. In this study, we found that aurone compound 7, which has been reported as a histone deacetylase (HDAC) inhibitor, gave false-positive results. Although compound 7 was identified by an in vitro HDAC fluorescence assay, it did not show HDAC inhibitory activity in a cell-based assay, leading us to suspect its in vitro HDAC inhibitory activity. As a result of verification experiments, we found that compound 7 interferes with the HDAC fluorescence assay by quenching the HDAC fluorescence signal. Our findings underscore the faults of fluorescence assays and call attention to careless interpretation.

  10. Model for High-Throughput Screening of Multitarget Drugs in Chemical Neurosciences: Synthesis, Assay, and Theoretic Study of Rasagiline Carbamates

    PubMed Central

    2013-01-01

    The disappointing results obtained in recent clinical trials renew the interest in experimental/computational techniques for the discovery of neuroprotective drugs. In this context, multitarget or multiplexing QSAR models (mt-QSAR/mx-QSAR) may help to predict neurotoxicity/neuroprotective effects of drugs in multiple assays, on drug targets, and in model organisms. In this work, we study a data set downloaded from CHEMBL; each data point (>8000) contains the values of one out of 37 possible measures of activity, 493 assays, 169 molecular or cellular targets, and 11 different organisms (including human) for a given compound. In this work, we introduce the first mx-QSAR model for neurotoxicity/neuroprotective effects of drugs based on the MARCH-INSIDE (MI) method. First, we used MI to calculate the stochastic spectral moments (structural descriptors) of all compounds. Next, we found a model that classified correctly 2955 out of 3548 total cases in the training and validation series with Accuracy, Sensitivity, and Specificity values > 80%. The model also showed excellent results in Computational-Chemistry simulations of High-Throughput Screening (CCHTS) experiments, with accuracy = 90.6% for 4671 positive cases. Next, we reported the synthesis, characterization, and experimental assays of new rasagiline derivatives. We carried out three different experimental tests: assay (1) in the absence of neurotoxic agents, assay (2) in the presence of glutamate, and assay (3) in the presence of H2O2. Compounds 11 with 27.4%, 8 with 11.6%, and 9 with 15.4% showed the highest neuroprotective effects in assays (1), (2), and (3), respectively. After that, we used the mx-QSAR model to carry out a CCHTS of the new compounds in >400 unique pharmacological tests not carried out experimentally. Consequently, this model may become a promising auxiliary tool for the discovery of new drugs for the treatment of neurodegenerative diseases. PMID:23855599

  11. Validation of an in vitro contractility assay using canine ventricular myocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harmer, A.R., E-mail: alex.harmer@astrazeneca.com; Abi-Gerges, N.; Morton, M.J.

    Measurement of cardiac contractility is a logical part of pre-clinical safety assessment in a drug discovery project, particularly if a risk has been identified or is suspected based on the primary- or non-target pharmacology. However, there are limited validated assays available that can be used to screen several compounds in order to identify and eliminate inotropic liability from a chemical series. We have therefore sought to develop an in vitro model with sufficient throughput for this purpose. Dog ventricular myocytes were isolated using a collagenase perfusion technique and placed in a perfused recording chamber on the stage of a microscopemore » at ∼ 36 °C. Myocytes were stimulated to contract at a pacing frequency of 1 Hz and a digital, cell geometry measurement system (IonOptix™) was used to measure sarcomere shortening in single myocytes. After perfusion with vehicle (0.1% DMSO), concentration–effect curves were constructed for each compound in 4–30 myocytes taken from 1 or 2 dog hearts. The validation test-set was 22 negative and 8 positive inotropes, and 21 inactive compounds, as defined by their effect in dog, cynolomolgous monkey or humans. By comparing the outcome of the assay to the known in vivo contractility effects, the assay sensitivity was 81%, specificity was 75%, and accuracy was 78%. With a throughput of 6–8 compounds/week from 1 cell isolation, this assay may be of value to drug discovery projects to screen for direct contractility effects and, if a hazard is identified, help identify inactive compounds. -- Highlights: ► Cardiac contractility is an important physiological function of the heart. ► Assessment of contractility is a logical part of pre-clinical drug safety testing. ► There are limited validated assays that predict effects of compounds on contractility. ► Using dog myocytes, we have developed an in vitro cardiac contractility assay. ► The assay predicted the in vivo contractility with a good level of accuracy.« less

  12. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    PubMed

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  13. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples

    PubMed Central

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J.

    2010-01-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study. PMID:21197228

  14. Receptor-based screening assays for the detection of antibiotics residues - A review.

    PubMed

    Ahmed, Saeed; Ning, Jianan; Cheng, Guyue; Ahmad, Ijaz; Li, Jun; Mingyue, Liu; Qu, Wei; Iqbal, Mujahid; Shabbir, M A B; Yuan, Zonghui

    2017-05-01

    Consumer and regulatory agencies have a high concern to antibiotic residues in food producing animals, so appropriate screening assays of fast, sensitive, low cost, and easy sample preparation for the identification of these residues are essential for the food-safety insurance. Great efforts in the development of a high-throughput antibiotic screening assay have been made in recent years. Concerning the screening of antibiotic residue, this review elaborate an overview on the availability, advancement and applicability of antibiotic receptor based screening assays for the safety assessment of antibiotics usage (i.e. radio receptor assay, enzyme labeling assays, colloidal gold receptor assay, enzyme colorimetry assay and biosensor assay). This manuscript also tries to shed a light on the selection, preparation and future perspective of receptor protein for antibiotic residue detection. These assays have been introduced for the screening of numerous food samples. Receptor based screening technology for antibiotic detection has high accuracy. It has been concluded that at the same time, it can detect a class of drugs for certain receptor, and realize the multi-residue detection. These assays offer fast, easy and precise detection of antibiotics. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Use of the Filovirus Animal Non-Clinical Group (FANG) Ebola virus immuno-assay requires fewer study participants to power a study than the Alpha Diagnostic International assay.

    PubMed

    Logue, James; Tuznik, Kaylie; Follmann, Dean; Grandits, Greg; Marchand, Jonathan; Reilly, Cavan; Sarro, Yeya Dit Sadio; Pettitt, James; Stavale, Eric J; Fallah, Mosoka; Olinger, Gene G; Bolay, Fatorma K; Hensley, Lisa E

    2018-05-01

    As part of the scientific community's development of medical countermeasures against Ebola virus disease, optimization of standardized assays for product evaluation is paramount. The recent outbreak heightened awareness to the scarcity of available assays and limited information on performance and reproducibility. To evaluate the immunogenicity of vaccines entering Phase I-III trials and to identify survivors, two enzyme-linked immunosorbent assays, the Filovirus Animal Non-Clinical Group assay and the Alpha Diagnostics International assay, were evaluated for detection of immunoglobulin G against Ebola virus glycoprotein. We found that the Filovirus Animal Nonclinical Group assay produced a wider range of relative antibody concentrations, higher assay precision, larger relative accuracy range, and lower regional background. Additionally, to sufficiently power a vaccine trial, use of the Filovirus Animal Nonclinical Group assay would require one third the number of participants than the Alpha Diagnostics International assay. This reduction in needed study participants will require less money, fewer man hours, and much less time to evaluate vaccine immunogenicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Automated detection of inaccurate and imprecise transitions in peptide quantification by multiple reaction monitoring mass spectrometry.

    PubMed

    Abbatiello, Susan E; Mani, D R; Keshishian, Hasmik; Carr, Steven A

    2010-02-01

    Multiple reaction monitoring mass spectrometry (MRM-MS) of peptides with stable isotope-labeled internal standards (SISs) is increasingly being used to develop quantitative assays for proteins in complex biological matrices. These assays can be highly precise and quantitative, but the frequent occurrence of interferences requires that MRM-MS data be manually reviewed, a time-intensive process subject to human error. We developed an algorithm that identifies inaccurate transition data based on the presence of interfering signal or inconsistent recovery among replicate samples. The algorithm objectively evaluates MRM-MS data with 2 orthogonal approaches. First, it compares the relative product ion intensities of the analyte peptide to those of the SIS peptide and uses a t-test to determine if they are significantly different. A CV is then calculated from the ratio of the analyte peak area to the SIS peak area from the sample replicates. The algorithm identified problematic transitions and achieved accuracies of 94%-100%, with a sensitivity and specificity of 83%-100% for correct identification of errant transitions. The algorithm was robust when challenged with multiple types of interferences and problematic transitions. This algorithm for automated detection of inaccurate and imprecise transitions (AuDIT) in MRM-MS data reduces the time required for manual and subjective inspection of data, improves the overall accuracy of data analysis, and is easily implemented into the standard data-analysis work flow. AuDIT currently works with results exported from MRM-MS data-processing software packages and may be implemented as an analysis tool within such software.

  17. Automated Detection of Inaccurate and Imprecise Transitions in Peptide Quantification by Multiple Reaction Monitoring Mass Spectrometry

    PubMed Central

    Abbatiello, Susan E.; Mani, D. R.; Keshishian, Hasmik; Carr, Steven A.

    2010-01-01

    BACKGROUND Multiple reaction monitoring mass spectrometry (MRM-MS) of peptides with stable isotope–labeled internal standards (SISs) is increasingly being used to develop quantitative assays for proteins in complex biological matrices. These assays can be highly precise and quantitative, but the frequent occurrence of interferences requires that MRM-MS data be manually reviewed, a time-intensive process subject to human error. We developed an algorithm that identifies inaccurate transition data based on the presence of interfering signal or inconsistent recovery among replicate samples. METHODS The algorithm objectively evaluates MRM-MS data with 2 orthogonal approaches. First, it compares the relative product ion intensities of the analyte peptide to those of the SIS peptide and uses a t-test to determine if they are significantly different. A CV is then calculated from the ratio of the analyte peak area to the SIS peak area from the sample replicates. RESULTS The algorithm identified problematic transitions and achieved accuracies of 94%–100%, with a sensitivity and specificity of 83%–100% for correct identification of errant transitions. The algorithm was robust when challenged with multiple types of interferences and problematic transitions. CONCLUSIONS This algorithm for automated detection of inaccurate and imprecise transitions (AuDIT) in MRM-MS data reduces the time required for manual and subjective inspection of data, improves the overall accuracy of data analysis, and is easily implemented into the standard data-analysis work flow. AuDIT currently works with results exported from MRM-MS data-processing software packages and may be implemented as an analysis tool within such software. PMID:20022980

  18. Simultaneous quantification of preactivated ifosfamide derivatives and of 4-hydroxyifosfamide by high performance liquid chromatography-tandem mass spectrometry in mouse plasma and its application to a pharmacokinetic study.

    PubMed

    Deroussent, Alain; Skarbek, Charles; Maury, Adeline; Chapuis, Hubert; Daudigeos-Dubus, Estelle; Le Dret, Ludivine; Durand, Sylvère; Couvreur, Patrick; Desmaële, Didier; Paci, Angelo

    2015-06-15

    The antitumor drug, ifosfamide (IFO), requires activation by cytochrome P450 (CYP) to form the active metabolite, 4-hydroxyisfosfamide (4-OHIFO), leading to toxic by-products at high dose. In order to overcome these drawbacks, preactivated ifosfamide derivatives (RXIFO) were designed to release 4-OHIFO without CYP involvement. A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the simultaneous quantification of 4-OHIFO, IFO and four derivatives RXIFO in mouse plasma using multiple reaction monitoring. Because of its instability in plasma, 4-OHIFO was immediately converted to the semi-carbazone derivative, 4-OHIFO-SCZ. For the six analytes, the calibration curves were linear from 20 to 5000ng/mL in 50μL plasma and the lower limit of quantitation was determined at 20ng/mL with accuracies within ±10% of nominal and precisions less than 12%. Their recoveries ranged from 62 to 96% by using liquid-liquid extraction. With an improved assay sensitivity compared to analogues, the derivative 4-OHIFO-SCZ was stable in plasma at 4°C for 24h and at -20°C for three months. For all compounds, the assay was validated with accuracies within ±13% and precisions less than 15%. This method was applied to a comparative pharmacokinetic study of 4-OHIFO from IFO and three derivatives RXIFO in mice. This active metabolite was produced by some of the novel conjugates with good pharmacokinetic properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Improving virtual screening predictive accuracy of Human kallikrein 5 inhibitors using machine learning models.

    PubMed

    Fang, Xingang; Bagui, Sikha; Bagui, Subhash

    2017-08-01

    The readily available high throughput screening (HTS) data from the PubChem database provides an opportunity for mining of small molecules in a variety of biological systems using machine learning techniques. From the thousands of available molecular descriptors developed to encode useful chemical information representing the characteristics of molecules, descriptor selection is an essential step in building an optimal quantitative structural-activity relationship (QSAR) model. For the development of a systematic descriptor selection strategy, we need the understanding of the relationship between: (i) the descriptor selection; (ii) the choice of the machine learning model; and (iii) the characteristics of the target bio-molecule. In this work, we employed the Signature descriptor to generate a dataset on the Human kallikrein 5 (hK 5) inhibition confirmatory assay data and compared multiple classification models including logistic regression, support vector machine, random forest and k-nearest neighbor. Under optimal conditions, the logistic regression model provided extremely high overall accuracy (98%) and precision (90%), with good sensitivity (65%) in the cross validation test. In testing the primary HTS screening data with more than 200K molecular structures, the logistic regression model exhibited the capability of eliminating more than 99.9% of the inactive structures. As part of our exploration of the descriptor-model-target relationship, the excellent predictive performance of the combination of the Signature descriptor and the logistic regression model on the assay data of the Human kallikrein 5 (hK 5) target suggested a feasible descriptor/model selection strategy on similar targets. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. The New Xpert MTB/RIF Ultra: Improving Detection of Mycobacterium tuberculosis and Resistance to Rifampin in an Assay Suitable for Point-of-Care Testing

    PubMed Central

    Simmons, Ann Marie; Rowneki, Mazhgan; Parmar, Heta; Cao, Yuan; Ryan, Jamie; Banada, Padmapriya P.; Deshpande, Srinidhi; Shenai, Shubhada; Gall, Alexander; Glass, Jennifer; Krieswirth, Barry; Schumacher, Samuel G.; Nabeta, Pamela; Tukvadze, Nestani; Rodrigues, Camilla; Skrahina, Alena; Tagliani, Elisa; Cirillo, Daniela M.; Davidow, Amy; Denkinger, Claudia M.; Persing, David; Kwiatkowski, Robert; Jones, Martin

    2017-01-01

    ABSTRACT The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. PMID:28851844

  1. Optimal triage test characteristics to improve the cost-effectiveness of the Xpert MTB/RIF assay for TB diagnosis: a decision analysis.

    PubMed

    van't Hoog, Anna H; Cobelens, Frank; Vassall, Anna; van Kampen, Sanne; Dorman, Susan E; Alland, David; Ellner, Jerrold

    2013-01-01

    High costs are a limitation to scaling up the Xpert MTB/RIF assay (Xpert) for the diagnosis of tuberculosis in resource-constrained settings. A triaging strategy in which a sensitive but not necessarily highly specific rapid test is used to select patients for Xpert may result in a more affordable diagnostic algorithm. To inform the selection and development of particular diagnostics as a triage test we explored combinations of sensitivity, specificity and cost at which a hypothetical triage test will improve affordability of the Xpert assay. In a decision analytical model parameterized for Uganda, India and South Africa, we compared a diagnostic algorithm in which a cohort of patients with presumptive TB received Xpert to a triage algorithm whereby only those with a positive triage test were tested by Xpert. A triage test with sensitivity equal to Xpert, 75% specificity, and costs of US$5 per patient tested reduced total diagnostic costs by 42% in the Uganda setting, and by 34% and 39% respectively in the India and South Africa settings. When exploring triage algorithms with lower sensitivity, the use of an example triage test with 95% sensitivity relative to Xpert, 75% specificity and test costs $5 resulted in similar cost reduction, and was cost-effective by the WHO willingness-to-pay threshold compared to Xpert for all in Uganda, but not in India and South Africa. The gain in affordability of the examined triage algorithms increased with decreasing prevalence of tuberculosis among the cohort. A triage test strategy could potentially improve the affordability of Xpert for TB diagnosis, particularly in low-income countries and with enhanced case-finding. Tests and markers with lower accuracy than desired of a diagnostic test may fall within the ranges of sensitivity, specificity and cost required for triage tests and be developed as such.

  2. Current V3 genotyping algorithms are inadequate for predicting X4 co-receptor usage in clinical isolates.

    PubMed

    Low, Andrew J; Dong, Winnie; Chan, Dennison; Sing, Tobias; Swanstrom, Ronald; Jensen, Mark; Pillai, Satish; Good, Benjamin; Harrigan, P Richard

    2007-09-12

    Integrating CCR5 antagonists into clinical practice would benefit from accurate assays of co-receptor usage (CCR5 versus CXCR4) with fast turnaround and low cost. Published HIV V3-loop based predictors of co-receptor usage were compared with actual phenotypic tropism results in a large cohort of antiretroviral naive individuals to determine accuracy on clinical samples and identify areas for improvement. Aligned HIV envelope V3 loop sequences (n = 977), derived by bulk sequencing were analyzed by six methods: the 11/25 rule; a neural network (NN), two support vector machines, and two subtype-B position specific scoring matrices (PSSM). Co-receptor phenotype results (Trofile Co-receptor Phenotype Assay; Monogram Biosciences) were stratified by CXCR4 relative light unit (RLU) readout and CD4 cell count. Co-receptor phenotype was available for 920 clinical samples with V3 genotypes having fewer than seven amino acid mixtures (n = 769 R5; n = 151 X4-capable). Sensitivity and specificity for predicting X4 capacity were evaluated for the 11/25 rule (30% sensitivity/93% specificity), NN (44%/88%), PSSM(sinsi) (34%/96%), PSSM(x4r5) (24%/97%), SVMgenomiac (22%/90%) and SVMgeno2pheno (50%/89%). Quantitative increases in sensitivity could be obtained by optimizing the cut-off for methods with continuous output (PSSM methods), and/or integrating clinical data (CD4%). Sensitivity was directly proportional to strength of X4 signal in the phenotype assay (P < 0.05). Current default implementations of co-receptor prediction algorithms are inadequate for predicting HIV X4 co-receptor usage in clinical samples, particularly those X4 phenotypes with low CXCR4 RLU signals. Significant improvements can be made to genotypic predictors, including training on clinical samples, using additional data to improve predictions and optimizing cutoffs and increasing genotype sensitivity.

  3. An improved Abbott ARCHITECT assay for the detection of hepatitis B virus surface antigen (HBsAg).

    PubMed

    Lou, Sheng C; Pearce, Sandra K; Lukaszewska, Teresa X; Taylor, Russell E; Williams, Gregg T; Leary, Thomas P

    2011-05-01

    The sensitive and accurate detection of hepatitis B virus surface antigen (HBsAg) is critical to the identification of infection and the prevention of transfusion transmitted disease. Improvement in HBsAg assay sensitivity is essential to reduce the window to detect an acute HBV infection. Additionally, the sensitive detection of HBsAg mutants that continue to evolve due to vaccine escape, immune selection and an error prone reverse transcriptase is a necessity. A fully automated HBsAg prototype assay on the Abbott ARCHITECT instrument was developed to improve sensitivity and mutant detection. This magnetic microparticle-based assay utilizes anti-HBsAg monoclonal antibodies to capture antigen present in serum or plasma. Captured antigen is then detected using anti-HBsAg antibody conjugated with the chemiluminescent compound, acridinium. The sensitivity of the ARCHITECT HBsAg prototype assay was improved as compared to the current ARCHITECT, PRISM, and competitor HBsAg assays. The enhancement in assay sensitivity was demonstrated by the use of commercially available HBV seroconversion panels. The prototype assay detected more panel members (185 of 383) vs. the current ARCHITECT (171), PRISM (181), or competitor HBsAg assays (73/140 vs. 62/140, respectively). The ARCHITECT prototype assay also efficiently detected all mutants evaluated. Finally, the sensitivity improvement did not compromise the specificity of the assay (99.94%). An improved Abbott ARCHITECT HBsAg prototype assay with enhanced detection of HBsAg and HBsAg mutants, as well as equivalent specificity was developed for the detection, diagnosis, and management of HBV infection. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Comparison of isolated cranberry (Vaccinium macrocarpon Ait.) proanthocyanidins to catechin and procyanidins A2 and B2 for use as standards in the 4-(dimethylamino)cinnamaldehyde assay.

    PubMed

    Feliciano, Rodrigo P; Shea, Michael P; Shanmuganayagam, Dhanansayan; Krueger, Christian G; Howell, Amy B; Reed, Jess D

    2012-05-09

    The 4-(dimethylamino)cinnamaldehyde (DMAC) assay is currently used to quantify proanthocyanidin (PAC) content in cranberry products. However, this method suffers from issues of accuracy and precision in the analysis and comparison of PAC levels across a broad range of cranberry products. Current use of procyanidin A2 as a standard leads to an underestimation of PACs content in certain cranberry products, especially those containing higher molecular weight PACs. To begin to address the issue of accuracy, a method for the production of a cranberry PAC standard, derived from an extraction of cranberry (c-PAC) press cake, was developed and evaluated. Use of the c-PAC standard to quantify PAC content in cranberry samples resulted in values that were 2.2 times higher than those determined by procyanidin A2. Increased accuracy is critical for estimating PAC content in relationship to research on authenticity, efficacy, and bioactivity, especially in designing clinical trials for determination of putative health benefits.

  5. Plasma Levels of Aβ42 and Tau Identified Probable Alzheimer's Dementia: Findings in Two Cohorts.

    PubMed

    Lue, Lih-Fen; Sabbagh, Marwan N; Chiu, Ming-Jang; Jing, Naomi; Snyder, Noelle L; Schmitz, Christopher; Guerra, Andre; Belden, Christine M; Chen, Ta-Fu; Yang, Che-Chuan; Yang, Shieh-Yueh; Walker, Douglas G; Chen, Kewei; Reiman, Eric M

    2017-01-01

    The utility of plasma amyloid beta (Aβ) and tau levels for the clinical diagnosis of Alzheimer's disease (AD) dementia has been controversial. The main objective of this study was to compare Aβ42 and tau levels measured by the ultra-sensitive immunomagnetic reduction (IMR) assays in plasma samples collected at the Banner Sun Health Institute (BSHRI) (United States) with those from the National Taiwan University Hospital (NTUH) (Taiwan). Significant increase in tau levels were detected in AD subjects from both cohorts, while Aβ42 levels were increased only in the NTUH cohort. A regression model incorporating age showed that tau levels identified probable ADs with 81 and 96% accuracy in the BSHRI and NTUH cohorts, respectively, while computed products of Aβ42 and tau increased the accuracy to 84% in the BSHRI cohorts. Using 382.68 (pg/ml) 2 as the cut-off value, the product achieved 92% accuracy in identifying AD in the combined cohorts. Overall findings support that plasma Aβ42 and tau assayed by IMR technology can be used to assist in the clinical diagnosis of AD.

  6. Development of an ESI-LC-MS-based assay for kinetic evaluation of Mycobacterium tuberculosis shikimate kinase activity and inhibition.

    PubMed

    Simithy, Johayra; Gill, Gobind; Wang, Yu; Goodwin, Douglas C; Calderón, Angela I

    2015-02-17

    A simple and reliable liquid chromatography-mass spectrometry (LC-MS) assay has been developed and validated for the kinetic characterization and evaluation of inhibitors of shikimate kinase from Mycobacterium tuberculosis (MtSK), a potential target for the development of novel antitubercular drugs. This assay is based on the direct determination of the reaction product shikimate-3-phosphate (S3P) using electrospray ionization (ESI) and a quadrupole time-of-flight (Q-TOF) detector. A comparative analysis of the kinetic parameters of MtSK obtained by the LC-MS assay with those obtained by a conventional UV-assay was performed. Kinetic parameters determined by LC-MS were in excellent agreement with those obtained from the UV assay, demonstrating the accuracy, and reliability of this method. The validated assay was successfully applied to the kinetic characterization of a known inhibitor of shikimate kinase; inhibition constants and mode of inhibition were accurately delineated with LC-MS.

  7. Single nucleotide polymorphism detection using gold nanoprobes and bio-microfluidic platform with embedded microlenses.

    PubMed

    Bernacka-Wojcik, Iwona; Águas, Hugo; Carlos, Fabio Ferreira; Lopes, Paulo; Wojcik, Pawel Jerzy; Costa, Mafalda Nascimento; Veigas, Bruno; Igreja, Rui; Fortunato, Elvira; Baptista, Pedro Viana; Martins, Rodrigo

    2015-06-01

    The use of microfluidics platforms combined with the optimal optical properties of gold nanoparticles has found plenty of application in molecular biosensing. This paper describes a bio-microfluidic platform coupled to a non-cross-linking colorimetric gold nanoprobe assay to detect a single nucleotide polymorphism associated with increased risk of obesity fat-mass and obesity-associated (FTO) rs9939609 (Carlos et al., 2014). The system enabled significant discrimination between positive and negative assays using a target DNA concentration of 5 ng/µL below the limit of detection of the conventionally used microplate reader (i.e., 15 ng/µL) with 10 times lower solution volume (i.e., 3 µL). A set of optimization of our previously reported bio-microfluidic platform (Bernacka-Wojcik et al., 2013) resulted in a 160% improvement of colorimetric analysis results. Incorporation of planar microlenses increased 6 times signal-to-loss ratio reaching the output optical fiber improving by 34% the colorimetric analysis of gold nanoparticles, while the implementation of an optoelectronic acquisition system yielded increased accuracy and reduced noise. The microfluidic chip was also integrated with a miniature fiber spectrometer to analyze the assays' colorimetric changes and also the LEDs transmission spectra when illuminating through various solutions. Furthermore, by coupling an optical microscope to a digital camera with a long exposure time (30 s), we could visualise the different scatter intensities of gold nanoparticles within channels following salt addition. These intensities correlate well to the expected difference in aggregation between FTO positive (none to small aggregates) and negative samples (large aggregates). © 2015 Wiley Periodicals, Inc.

  8. Performance Characteristics of Commercial Immunoassays for the Detection of IgG and IgM Antibodies to β2 Glycoprotein I and an Initial Assessment of Newly Developed Reference Materials for Assay Calibration.

    PubMed

    Willis, Rohan; Pierangeli, Silvia S; Jaskowski, Troy D; Malmberg, Elisabeth; Guerra, Marta; Salmon, Jane E; Petri, Michelle; Branch, D Ware; Tebo, Anne E

    2016-06-01

    To investigate the performance characteristics and impact of newly developed reference calibrators on the commutability between anti-β2 glycoprotein I (anti-β2 GPI) immunoassays in antiphospholipid syndrome (APS) and/or systemic lupus erythematosus (SLE). Immunoglobulin G (IgG) and immunoglobulin M (IgM) anti-β2 GPI immunoassays from four manufacturers were evaluated. Serum samples from 269 patients (APS only, n = 31; SLE and APS, n = 83; SLE only, n = 129; pregnancy-related clinical manifestations without APS, n = 26) and 162 women with histories of successful pregnancies were tested. Results were expressed in kit-specific arbitrary units and in the calibrator reference units (RUs) based on 99th percentile cutoff values. Diagnostic accuracies, correlation between kits, and specific clinical manifestations in APS were investigated. The sensitivities of the assays ranged from 15.8% to 27.2% (IgG) and 12.3% to 15.8% (IgM) while specificities ranged from 79.4% to 86.5% (IgG) and 80.6% to 84.5% (IgM). There was moderate to almost perfect interassay reliability (Cohen κ, 0.69-0.98), and Spearman correlation coefficients were generally improved when results of the IgG determinations were expressed in RUs. Although qualitative agreements between immunoassays for both antibody isotypes are acceptable, correlations with APS clinical manifestations were kit dependent. Only the use of IgG reference material improved quantitative correlations between assays. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. ADDME – Avoiding Drug Development Mistakes Early: central nervous system drug discovery perspective

    PubMed Central

    Tsaioun, Katya; Bottlaender, Michel; Mabondzo, Aloise

    2009-01-01

    The advent of early absorption, distribution, metabolism, excretion, and toxicity (ADMET) screening has increased the attrition rate of weak drug candidates early in the drug-discovery process, and decreased the proportion of compounds failing in clinical trials for ADMET reasons. This paper reviews the history of ADMET screening and its place in pharmaceutical development, and central nervous system drug discovery in particular. Assays that have been developed in response to specific needs and improvements in technology that result in higher throughput and greater accuracy of prediction of human mechanisms of absorption and toxicity are discussed. The paper concludes with the authors' forecast of new models that will better predict human efficacy and toxicity. PMID:19534730

  10. Immunoliposome-PCR: a generic ultrasensitive quantitative antigen detection system

    PubMed Central

    2012-01-01

    Background The accurate quantification of antigens at low concentrations over a wide dynamic range is needed for identifying biomarkers associated with disease and detecting protein interactions in high-throughput microarrays used in proteomics. Here we report the development of an ultrasensitive quantitative assay format called immunoliposome polymerase chain reaction (ILPCR) that fulfills these requirements. This method uses a liposome, with reporter DNA encapsulated inside and biotin-labeled polyethylene glycol (PEG) phospholipid conjugates incorporated into the outer surface of the liposome, as a detection reagent. The antigenic target is immobilized in the well of a microplate by a capture antibody and the liposome detection reagent is then coupled to a biotin-labeled second antibody through a NeutrAvidin bridge. The liposome is ruptured to release the reporter DNA, which serves as a surrogate to quantify the protein target using real-time PCR. Results A liposome detection reagent was prepared, which consisted of a population of liposomes ~120 nm in diameter with each liposome possessing ~800 accessible biotin receptors and ~220 encapsulated reporters. This liposome detection reagent was used in an assay to quantify the concentration of carcinoembryonic antigen (CEA) in human serum. This ILPCR assay exhibited a linear dose–response curve from 10-10 M to 10-16 M CEA. Within this range the assay coefficient of variance was <6 % for repeatability and <2 % for reproducibility. The assay detection limit was 13 fg/mL, which is 1,500-times more sensitive than current clinical assays for CEA. An ILPCR assay to quantify HIV-1 p24 core protein in buffer was also developed. Conclusions The ILPCR assay has several advantages over other immuno-PCR methods. The reporter DNA and biotin-labeled PEG phospholipids spontaneously incorporate into the liposomes as they form, simplifying preparation of the detection reagent. Encapsulation of the reporter inside the liposomes allows nonspecific DNA in the assay medium to be degraded with DNase I prior to quantification of the encapsulated reporter by PCR, which reduces false-positive results and improves quantitative accuracy. The ability to encapsulate multiple reporters per liposome also helps overcome the effect of polymerase inhibitors present in biological specimens. Finally, the biotin-labeled liposome detection reagent can be coupled through a NeutrAvidin bridge to a multitude of biotin-labeled probes, making ILPCR a highly generic assay system. PMID:22726242

  11. Bioanalytical qualification of clinical biomarker assays in plasma using a novel multi-analyte Simple Plex™ platform.

    PubMed

    Gupta, Vinita; Davancaze, Teresa; Good, Jeremy; Kalia, Navdeep; Anderson, Michael; Wallin, Jeffrey J; Brady, Ann; Song, An; Xu, Wenfeng

    2016-12-01

    Immune-checkpoint inhibitors are presumed to break down the tolerogenic state of immune cells by activating T-lymphocytes that release cytokines and enhance effector cell function for elimination of tumors. Measurement of cytokines is being pursued for better understanding of the mechanism of action of immune-checkpoint inhibitors, as well as to identify potential predictive biomarkers. In this study, we show bioanalytical qualification of cytokine assays in plasma on a novel multi-analyte immunoassay platform, Simple Plex ™ . The qualified assays exhibited excellent sensitivity as evidenced by measurement of all samples within the quantifiable range. The accuracy and precision were 80-120% and 10%, respectively. The qualified assays will be useful in assessing mechanism of action cancer immunotherapies.

  12. Persistent Graves' hyperthyroidism despite rapid negative conversion of thyroid-stimulating hormone-binding inhibitory immunoglobulin assay results: a case report.

    PubMed

    Ohara, Nobumasa; Kaneko, Masanori; Kitazawa, Masaru; Uemura, Yasuyuki; Minagawa, Shinichi; Miyakoshi, Masashi; Kaneko, Kenzo; Kamoi, Kyuzi

    2017-02-06

    Graves' disease is an autoimmune thyroid disorder characterized by hyperthyroidism, and patients exhibit thyroid-stimulating hormone receptor antibody. The major methods of measuring circulating thyroid-stimulating hormone receptor antibody include the thyroid-stimulating hormone-binding inhibitory immunoglobulin assays. Although the diagnostic accuracy of these assays has been improved, a minority of patients with Graves' disease test negative even on second-generation and third-generation thyroid-stimulating hormone-binding inhibitory immunoglobulins. We report a rare case of a thyroid-stimulating hormone-binding inhibitory immunoglobulin-positive patient with Graves' disease who showed rapid lowering of thyroid-stimulating hormone-binding inhibitory immunoglobulin levels following administration of the anti-thyroid drug thiamazole, but still experienced Graves' hyperthyroidism. A 45-year-old Japanese man presented with severe hyperthyroidism (serum free triiodothyronine >25.0 pg/mL; reference range 1.7 to 3.7 pg/mL) and tested weakly positive for thyroid-stimulating hormone-binding inhibitory immunoglobulins on second-generation tests (2.1 IU/L; reference range <1.0 IU/L). Within 9 months of treatment with oral thiamazole (30 mg/day), his thyroid-stimulating hormone-binding inhibitory immunoglobulin titers had normalized, but he experienced sustained hyperthyroidism for more than 8 years, requiring 15 mg/day of thiamazole to correct. During that period, he tested negative on all first-generation, second-generation, and third-generation thyroid-stimulating hormone-binding inhibitory immunoglobulin assays, but thyroid scintigraphy revealed diffuse and increased uptake, and thyroid ultrasound and color flow Doppler imaging showed typical findings of Graves' hyperthyroidism. The possible explanations for serial changes in the thyroid-stimulating hormone-binding inhibitory immunoglobulin results in our patient include the presence of thyroid-stimulating hormone receptor antibody, which is bioactive but less reactive on thyroid-stimulating hormone-binding inhibitory immunoglobulin assays, or the effect of reduced levels of circulating thyroid-stimulating hormone receptor antibody upon improvement of thyroid autoimmunity with thiamazole treatment. Physicians should keep in mind that patients with Graves' disease may show thyroid-stimulating hormone-binding inhibitory immunoglobulin assay results that do not reflect the severity of Graves' disease or indicate the outcome of the disease, and that active Graves' disease may persist even after negative results on thyroid-stimulating hormone-binding inhibitory immunoglobulin assays. Timely performance of thyroid function tests in combination with sensitive imaging tests, including thyroid ultrasound and scintigraphy, are necessary to evaluate the severity of Graves' disease and treatment efficacy.

  13. Quantitation of a PEGylated protein in monkey serum by UHPLC-HRMS using a surrogate disulfide-containing peptide: A new approach to bioanalysis and in vivo stability evaluation of disulfide-rich protein therapeutics.

    PubMed

    Zheng, Naiyu; Zeng, Jianing; Manney, Amy; Williams, Lakenya; Aubry, Anne-Françoise; Voronin, Kimberly; Buzescu, Adela; Zhang, Yan J; Allentoff, Alban; Xu, Carrie; Shen, Hongwu; Warner, William; Arnold, Mark E

    2016-04-15

    To quantify a therapeutic PEGylated protein in monkey serum as well as to monitor its potential in vivo instability and methionine oxidation, a novel ultra high performance liquid chromatography-high resolution mass spectrometric (UHPLC-HRMS) assay was developed using a surrogate disulfide-containing peptide, DCP(SS), and a confirmatory peptide, CP, a disulfide-free peptide. DCP(SS) was obtained by eliminating the step of reduction/alkylation before trypsin digestion. It contains an intact disulfide linkage between two peptide sequences that are essential for drug function but susceptible to potential in vivo cleavages. HRMS-based single ion monitoring (SIM) on a Q Exactive™ mass spectrometer was employed to improve assay specificity and sensitivity for DCP(SS) due to its poor fragmentation and low sensitivity with SRM detection. The assay has been validated for the protein drug in monkey serum using both surrogate peptides with excellent accuracy (within ±4.4%Dev) and precision (within 7.5%CV) with a lower limit of quantitation (LLOQ) at 10 ng mL(-1). The protein concentrations in monkey serum obtained from the DCP(SS)-based assay not only provided important pharmacokinetic parameters, but also confirmed in vivo stability of the peptide regions of interest by comparing drug concentrations with those obtained from the CP-based assay or from a ligand-binding assay (LBA). Furthermore, UHPLC-HRMS allowed simultaneous monitoring of the oxidized forms of both surrogate peptides to evaluate potential ex vivo/in vivo oxidation of one methionine present in each of both surrogate peptides. To the best of our knowledge, this is the first report of using a surrogate disulfide-containing peptide for LC-MS bioanalysis of a therapeutic protein. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Admission Cell Free DNA Levels Predict 28-Day Mortality in Patients with Severe Sepsis in Intensive Care

    PubMed Central

    Almog, Yaniv; Perl, Yael; Novack, Victor; Galante, Ori; Klein, Moti; Pencina, Michael J.; Douvdevani, Amos

    2014-01-01

    Aim The aim of the current study is to assess the mortality prediction accuracy of circulating cell-free DNA (CFD) level at admission measured by a new simplified method. Materials and Methods CFD levels were measured by a direct fluorescence assay in severe sepsis patients on intensive care unit (ICU) admission. In-hospital and/or twenty eight day all-cause mortality was the primary outcome. Results Out of 108 patients with median APACHE II of 20, 32.4% have died in hospital/or at 28-day. CFD levels were higher in decedents: median 3469.0 vs. 1659 ng/ml, p<0.001. In multivariable model APACHE II score and CFD (quartiles) were significantly associated with the mortality: odds ratio of 1.05, p = 0.049 and 2.57, p<0.001 per quartile respectively. C-statistics for the models was 0.79 for CFD and 0.68 for APACHE II. Integrated discrimination improvement (IDI) analyses showed that CFD and CFD+APACHE II score models had better discriminatory ability than APACHE II score alone. Conclusions CFD level assessed by a new, simple fluorometric-assay is an accurate predictor of acute mortality among ICU patients with severe sepsis. Comparison of CFD to APACHE II score and Procalcitonin (PCT), suggests that CFD has the potential to improve clinical decision making. PMID:24955978

  15. Determining Vitamin D Status: A Comparison between Commercially Available Assays

    PubMed Central

    Snellman, Greta; Melhus, Håkan; Gedeborg, Rolf; Byberg, Liisa; Berglund, Lars; Wernroth, Lisa; Michaëlsson, Karl

    2010-01-01

    Background Vitamin D is not only important for bone health but can also affect the development of several non-bone diseases. The definition of vitamin D insufficiency by serum levels of 25-hydroxyvitamin D depends on the clinical outcome but might also be a consequence of analytical methods used for the definition. Although numerous 25-hydroxyvitamin D assays are available, their comparability is uncertain. We therefore aim to investigate the precision, accuracy and clinical consequences of differences in performance between three common commercially available assays. Methodology/Principal Findings Serum 25-hydroxyvitamin D levels from 204 twins from the Swedish Twin Registry were determined with high-pressure liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS), a radioimmunoassay (RIA) and a chemiluminescent immunoassay (CLIA). High inter-assay disagreement was found. Mean 25-hydroxyvitamin D levels were highest for the HPLC-APCI-MS technique (85 nmol/L, 95% CI 81–89), intermediate for RIA (70 nmol/L, 95% CI 66–74) and lowest with CLIA (60 nmol/L, 95% CI 56–64). Using a 50-nmol/L cut-off, 8% of the subjects were insufficient using HPLC-APCI-MS, 22% with RIA and 43% by CLIA. Because of the heritable component of 25-hydroxyvitamin D status, the accuracy of each method could indirectly be assessed by comparison of within-twin pair correlations. The strongest correlation was found for HPLC-APCI-MS (r = 0.7), intermediate for RIA (r = 0.5) and lowest for CLIA (r = 0.4). Regression analyses between the methods revealed a non-uniform variance (p<0.0001) depending on level of 25-hydroxyvitamin D. Conclusions/Significance There are substantial inter-assay differences in performance. The most valid method was HPLC-APCI-MS. Calibration between 25-hydroxyvitamin D assays is intricate. PMID:20644628

  16. Determination of dietary starch in animal feeds and pet food by an enzymatic-colorimetric method: collaborative study.

    PubMed

    Hall, Mary Beth

    2015-01-01

    Starch, glycogen, maltooligosaccharides, and other α-1,4- and α-1,6-linked glucose carbohydrates, exclusive of resistant starch, are collectively termed "dietary starch". This nutritionally important fraction is increasingly measured for use in diet formulation for animals as it can have positive or negative effects on animal performance and health by affecting energy supply, glycemic index, and formation of fermentation products by gut microbes. AOAC Method 920.40 that was used for measuring dietary starch in animal feeds was invalidated due to discontinued production of a required enzyme. As a replacement, an enzymatic-colorimetric starch assay developed in 1997 that had advantages in ease of sample handling and accuracy compared to other methods was considered. The assay was further modified to improve utilization of laboratory resources and reduce time required for the assay. The assay is quasi-empirical: glucose is the analyte detected, but its release is determined by run conditions and specification of enzymes. The modified assay was tested in an AOAC collaborative study to evaluate its accuracy and reliability for determination of dietary starch in animal feedstuffs and pet foods. In the assay, samples are incubated in screw cap tubes with thermostable α-amylase in pH 5.0 sodium acetate buffer for 1 h at 100°C with periodic mixing to gelatinize and partially hydrolyze α-glucan. Amyloglucosidase is added, and the reaction mixture is incubated at 50°C for 2 h and mixed once. After subsequent addition of water, mixing, clarification, and dilution as needed, free + enzymatically released glucose are measured. Values from a separate determination of free glucose are subtracted to give values for enzymatically released glucose. Dietary starch equals enzymatically released glucose multiplied by 162/180 (or 0.9) divided by the weight of the as received sample. Fifteen laboratories that represented feed company, regulatory, research, and commercial feed testing laboratories analyzed 10 homogenous test materials representing animal feedstuffs and pet foods in duplicate using the dietary starch assay. The test samples ranged from 1 to 70% in dietary starch content and included moist canned dog food, alfalfa pellets, distillers grains, ground corn grain, poultry feed, low starch horse feed, dry dog kibbles, complete dairy cattle feed, soybean meal, and corn silage. The average within-laboratory repeatability SD (sr) for percentage dietary starch in the test samples was 0.49 with a range of 0.03 to 1.56, and among-laboratory repeatability SDs (sR) averaged 0.96 with a range of 0.09 to 2.69. The HorRat averaged 2.0 for all test samples and 1.9 for test samples containing greater than 2% dietary starch. The HorRat results are comparable to those found for AOAC Method 996.11, which measures starch in cereal products. It is recommended that the dietary starch method be accepted for Official First Action status.

  17. A Rapid, High-Quality, Cost-Effective, Comprehensive and Expandable Targeted Next-Generation Sequencing Assay for Inherited Heart Diseases.

    PubMed

    Wilson, Kitchener D; Shen, Peidong; Fung, Eula; Karakikes, Ioannis; Zhang, Angela; InanlooRahatloo, Kolsoum; Odegaard, Justin; Sallam, Karim; Davis, Ronald W; Lui, George K; Ashley, Euan A; Scharfe, Curt; Wu, Joseph C

    2015-09-11

    Thousands of mutations across >50 genes have been implicated in inherited cardiomyopathies. However, options for sequencing this rapidly evolving gene set are limited because many sequencing services and off-the-shelf kits suffer from slow turnaround, inefficient capture of genomic DNA, and high cost. Furthermore, customization of these assays to cover emerging targets that suit individual needs is often expensive and time consuming. We sought to develop a custom high throughput, clinical-grade next-generation sequencing assay for detecting cardiac disease gene mutations with improved accuracy, flexibility, turnaround, and cost. We used double-stranded probes (complementary long padlock probes), an inexpensive and customizable capture technology, to efficiently capture and amplify the entire coding region and flanking intronic and regulatory sequences of 88 genes and 40 microRNAs associated with inherited cardiomyopathies, congenital heart disease, and cardiac development. Multiplexing 11 samples per sequencing run resulted in a mean base pair coverage of 420, of which 97% had >20× coverage and >99% were concordant with known heterozygous single nucleotide polymorphisms. The assay correctly detected germline variants in 24 individuals and revealed several polymorphic regions in miR-499. Total run time was 3 days at an approximate cost of $100 per sample. Accurate, high-throughput detection of mutations across numerous cardiac genes is achievable with complementary long padlock probe technology. Moreover, this format allows facile insertion of additional probes as more cardiomyopathy and congenital heart disease genes are discovered, giving researchers a powerful new tool for DNA mutation detection and discovery. © 2015 American Heart Association, Inc.

  18. A highly addressable static droplet array enabling digital control of a single droplet at pico-volume resolution.

    PubMed

    Jeong, Heon-Ho; Lee, Byungjin; Jin, Si Hyung; Jeong, Seong-Geun; Lee, Chang-Soo

    2016-04-26

    Droplet-based microfluidics enabling exquisite liquid-handling has been developed for diagnosis, drug discovery and quantitative biology. Compartmentalization of samples into a large number of tiny droplets is a great approach to perform multiplex assays and to improve reliability and accuracy using a limited volume of samples. Despite significant advances in microfluidic technology, individual droplet handling in pico-volume resolution is still a challenge in obtaining more efficient and varying multiplex assays. We present a highly addressable static droplet array (SDA) enabling individual digital manipulation of a single droplet using a microvalve system. In a conventional single-layer microvalve system, the number of microvalves required is dictated by the number of operation objects; thus, individual trap-and-release on a large-scale 2D array format is highly challenging. By integrating double-layer microvalves, we achieve a "balloon" valve that preserves the pressure-on state under released pressure; this valve can allow the selective releasing and trapping of 7200 multiplexed pico-droplets using only 1 μL of sample without volume loss. This selectivity and addressability completely arranged only single-cell encapsulated droplets from a mixture of droplet compositions via repetitive selective trapping and releasing. Thus, it will be useful for efficient handling of miniscule volumes of rare or clinical samples in multiplex or combinatory assays, and the selective collection of samples.

  19. Novel Uses of In Vitro Data to Develop Quantitative Biological Activity Relationship Models for in Vivo Carcinogenicity Prediction.

    PubMed

    Pradeep, Prachi; Povinelli, Richard J; Merrill, Stephen J; Bozdag, Serdar; Sem, Daniel S

    2015-04-01

    The availability of large in vitro datasets enables better insight into the mode of action of chemicals and better identification of potential mechanism(s) of toxicity. Several studies have shown that not all in vitro assays can contribute as equal predictors of in vivo carcinogenicity for development of hybrid Quantitative Structure Activity Relationship (QSAR) models. We propose two novel approaches for the use of mechanistically relevant in vitro assay data in the identification of relevant biological descriptors and development of Quantitative Biological Activity Relationship (QBAR) models for carcinogenicity prediction. We demonstrate that in vitro assay data can be used to develop QBAR models for in vivo carcinogenicity prediction via two case studies corroborated with firm scientific rationale. The case studies demonstrate the similarities between QBAR and QSAR modeling in: (i) the selection of relevant descriptors to be used in the machine learning algorithm, and (ii) the development of a computational model that maps chemical or biological descriptors to a toxic endpoint. The results of both the case studies show: (i) improved accuracy and sensitivity which is especially desirable under regulatory requirements, and (ii) overall adherence with the OECD/REACH guidelines. Such mechanism based models can be used along with QSAR models for prediction of mechanistically complex toxic endpoints. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Performance of a Highly Sensitive Mycobacterium tuberculosis Complex Real-Time PCR Assay for Diagnosis of Pulmonary Tuberculosis in a Low-Prevalence Setting: a Prospective Intervention Study.

    PubMed

    Vinuesa, Víctor; Borrás, Rafael; Briones, María Luisa; Clari, María Ángeles; Cresencio, Vicenta; Giménez, Estela; Muñoz, Carmen; Oltra, Rosa; Servera, Emilio; Scheelje, Talia; Tornero, Carlos; Navarro, David

    2018-05-01

    The potential impact of routine real-time PCR testing of respiratory specimens from patients with presumptive tuberculosis in terms of diagnostic accuracy and time to tuberculosis treatment inception in low-prevalence settings remains largely unexplored. We conducted a prospective intervention cohort study. Respiratory specimens from 1,020 patients were examined by acid-fast bacillus smear microscopy, tested by a real-time Mycobacterium tuberculosis complex PCR assay (Abbott RealTi me MTB PCR), and cultured in mycobacterial media. Seventeen patients tested positive by PCR (5 were acid-fast bacillus smear positive and 12 acid-fast bacillus smear negative), and Mycobacterium tuberculosis was recovered from cultures for 12 of them. Patients testing positive by PCR and negative by culture ( n = 5) were treated and deemed to have responded to antituberculosis therapy. There were no PCR-negative/culture-positive cases, and none of the patients testing positive for nontuberculous mycobacteria ( n = 20) yielded a positive PCR result. The data indicated that routine testing of respiratory specimens from patients with presumptive tuberculosis by the RealTi me MTB PCR assay improves the tuberculosis diagnostic yield and may reduce the time to antituberculosis treatment initiation. On the basis of our data, we propose a novel mycobacterial laboratory algorithm for tuberculosis diagnosis. Copyright © 2018 American Society for Microbiology.

  1. Improving Accuracy in Arrhenius Models of Cell Death: Adding a Temperature-Dependent Time Delay.

    PubMed

    Pearce, John A

    2015-12-01

    The Arrhenius formulation for single-step irreversible unimolecular reactions has been used for many decades to describe the thermal damage and cell death processes. Arrhenius predictions are acceptably accurate for structural proteins, for some cell death assays, and for cell death at higher temperatures in most cell lines, above about 55 °C. However, in many cases--and particularly at hyperthermic temperatures, between about 43 and 55 °C--the particular intrinsic cell death or damage process under study exhibits a significant "shoulder" region that constant-rate Arrhenius models are unable to represent with acceptable accuracy. The primary limitation is that Arrhenius calculations always overestimate the cell death fraction, which leads to severely overoptimistic predictions of heating effectiveness in tumor treatment. Several more sophisticated mathematical model approaches have been suggested and show much-improved performance. But simpler models that have adequate accuracy would provide useful and practical alternatives to intricate biochemical analyses. Typical transient intrinsic cell death processes at hyperthermic temperatures consist of a slowly developing shoulder region followed by an essentially constant-rate region. The shoulder regions have been demonstrated to arise chiefly from complex functional protein signaling cascades that generate delays in the onset of the constant-rate region, but may involve heat shock protein activity as well. This paper shows that acceptably accurate and much-improved predictions in the simpler Arrhenius models can be obtained by adding a temperature-dependent time delay. Kinetic coefficients and the appropriate time delay are obtained from the constant-rate regions of the measured survival curves. The resulting predictions are seen to provide acceptably accurate results while not overestimating cell death. The method can be relatively easily incorporated into numerical models. Additionally, evidence is presented to support the application of compensation law behavior to the cell death processes--that is, the strong correlation between the kinetic coefficients, ln{A} and E(a), is confirmed.

  2. A rapid enzymatic assay for high-throughput screening of adenosine-producing strains

    PubMed Central

    Dong, Huina; Zu, Xin; Zheng, Ping; Zhang, Dawei

    2015-01-01

    Adenosine is a major local regulator of tissue function and industrially useful as precursor for the production of medicinal nucleoside substances. High-throughput screening of adenosine overproducers is important for industrial microorganism breeding. An enzymatic assay of adenosine was developed by combined adenosine deaminase (ADA) with indophenol method. The ADA catalyzes the cleavage of adenosine to inosine and NH3, the latter can be accurately determined by indophenol method. The assay system was optimized to deliver a good performance and could tolerate the addition of inorganic salts and many nutrition components to the assay mixtures. Adenosine could be accurately determined by this assay using 96-well microplates. Spike and recovery tests showed that this assay can accurately and reproducibly determine increases in adenosine in fermentation broth without any pretreatment to remove proteins and potentially interfering low-molecular-weight molecules. This assay was also applied to high-throughput screening for high adenosine-producing strains. The high selectivity and accuracy of the ADA assay provides rapid and high-throughput analysis of adenosine in large numbers of samples. PMID:25580842

  3. A new D-dimer cutoff in bedridden hospitalized elderly patients.

    PubMed

    Granziera, Serena; Rechichi, Alfonsina; De Rui, Marina; De Carlo, Paola; Bertozzo, Giulia; Marigo, Lucia; Nante, Giovanni; Manzato, Enzo

    2013-03-01

    Asymptomatic deep vein thrombosis (DVT) and pulmonary embolism are leading causes of morbidity following the hospitalization of elderly people. The diagnosis of DVT is supported by the D-dimer laboratory assay. The concentration of D-dimer increases in patients with DVT, but may be high in other conditions too (i.e. cancer, infections and inflammation). Old age coincides with a physiological increase in D-dimer values, and that is why D-dimer assay in the elderly is characteristically highly sensitive but scarcely specific. The aim of our study was to explore the reliability of different D-dimer cutoffs for the diagnosis of asymptomatic DVT in a population of bedridden hospitalized elderly patients. We studied 199 patients who were a mean 86.3 ± 6.7 years old. All participants underwent lower limb Doppler ultrasound (DUS) and D-dimer venous blood sampling on admission. In our cohort, the usual cutoff proved highly sensitive (100%), but its specificity was very poor (20.1%). To find a higher cutoff that could improve the method's specificity, we analyzed our data using a receiver operating characteristic curve analysis. The resulting D-dimer cutoff of 492 μg/l enabled us to retain the same sensitivity while improving the test's specificity to 39.1%, with a consequent improvement in its positive predictive value and accuracy. In addition to improving the method's reliability, this result may be helpful in clinical practice, in both medical wards and nursing homes. By adopting a cutoff of 492 μg/l, clinicians could significantly increase the proportion of older patients in whom DVT can be safely ruled out, reducing referrals for DUS and administration of heparin, with consequent clinical, practical and economic advantages.

  4. Exploitation of data from breeding programs supports rapid implementation of genomic selection for key agronomic traits in perennial ryegrass.

    PubMed

    Pembleton, Luke W; Inch, Courtney; Baillie, Rebecca C; Drayton, Michelle C; Thakur, Preeti; Ogaji, Yvonne O; Spangenberg, German C; Forster, John W; Daetwyler, Hans D; Cogan, Noel O I

    2018-06-02

    Exploitation of data from a ryegrass breeding program has enabled rapid development and implementation of genomic selection for sward-based biomass yield with a twofold-to-threefold increase in genetic gain. Genomic selection, which uses genome-wide sequence polymorphism data and quantitative genetics techniques to predict plant performance, has large potential for the improvement in pasture plants. Major factors influencing the accuracy of genomic selection include the size of reference populations, trait heritability values and the genetic diversity of breeding populations. Global diversity of the important forage species perennial ryegrass is high and so would require a large reference population in order to achieve moderate accuracies of genomic selection. However, diversity of germplasm within a breeding program is likely to be lower. In addition, de novo construction and characterisation of reference populations are a logistically complex process. Consequently, historical phenotypic records for seasonal biomass yield and heading date over a 18-year period within a commercial perennial ryegrass breeding program have been accessed, and target populations have been characterised with a high-density transcriptome-based genotyping-by-sequencing assay. Ability to predict observed phenotypic performance in each successive year was assessed by using all synthetic populations from previous years as a reference population. Moderate and high accuracies were achieved for the two traits, respectively, consistent with broad-sense heritability values. The present study represents the first demonstration and validation of genomic selection for seasonal biomass yield within a diverse commercial breeding program across multiple years. These results, supported by previous simulation studies, demonstrate the ability to predict sward-based phenotypic performance early in the process of individual plant selection, so shortening the breeding cycle, increasing the rate of genetic gain and allowing rapid adoption in ryegrass improvement programs.

  5. Relationship between estimated pretest probability and accuracy of automated Mycobacterium tuberculosis assay in smear-negative pulmonary tuberculosis.

    PubMed

    Lim, T K; Gough, A; Chin, N K; Kumarasinghe, G

    2000-09-01

    The AMPLICOR assay (Roche; Branchburg, NJ), a rapid direct amplification test for Mycobacterium tuberculosis, has only been licensed for use in smear-positive respiratory specimens. However, many patients with pulmonary tuberculosis (PTB) have smear-negative disease. The clinical utility of this test in patients with smear-negative PTB is unknown. To evaluate the effect of pretest probability of PTB estimated by chest physicians on the accuracy of the AMPLICOR assay in patients with smear-negative PTB. A prospective study of consecutive patients suspected of having smear-negative PTB. Two chest physicians estimated the pretest probability of active disease (high, intermediate, and low categories). Respiratory specimens were examined with radiometric broth medium cultures and with the AMPLICOR assay for M tuberculosis. The decision on a final diagnosis of PTB was blinded to the AMPLICOR results. Active PTB was diagnosed in 25 of 441 patients (5.7%). The AMPLICOR assay had an overall sensitivity of 44% and a specificity of 99%. Results of the assay were negative in seven patients with culture-negative PTB. The proportions of patients in the high, intermediate, and low pretest groups were 4.5%, 19.7%, and 75.7%, respectively. The incidence of PTB for each group was 95%, 3.4%, and 0.9%, respectively. The sensitivities of the AMPLICOR assay in the three groups of patients were 47%, 33%, and 33%, respectively, while the specificities were 100%, 98%, and 99%, respectively. In patients suspected of having smear-negative PTB, the following conclusions were drawn: (1) the incidence of active PTB was low; (2) pretest estimates accurately discriminated between patients with high and low risk of PTB; (3) the risk of PTB was overestimated in the intermediate group; and (4) the utility of the AMPLICOR assay in the intermediate-risk group may be limited by the overestimation of disease prevalence and low test sensitivity. Further studies are needed on the role of the AMPLICOR assay in better selected patients with an intermediate risk of having smear-negative PTB.

  6. Can verbal working memory training improve reading?

    PubMed

    Banales, Erin; Kohnen, Saskia; McArthur, Genevieve

    2015-01-01

    The aim of the current study was to determine whether poor verbal working memory is associated with poor word reading accuracy because the former causes the latter, or the latter causes the former. To this end, we tested whether (a) verbal working memory training improves poor verbal working memory or poor word reading accuracy, and whether (b) reading training improves poor reading accuracy or verbal working memory in a case series of four children with poor word reading accuracy and verbal working memory. Each child completed 8 weeks of verbal working memory training and 8 weeks of reading training. Verbal working memory training improved verbal working memory in two of the four children, but did not improve their reading accuracy. Similarly, reading training improved word reading accuracy in all children, but did not improve their verbal working memory. These results suggest that the causal links between verbal working memory and reading accuracy may not be as direct as has been assumed.

  7. Novel electrochemical immune sensor based on Hep-PGA-PPy nanoparticles for detection of α-Fetoprotein in whole blood.

    PubMed

    Xu, Tingting; Chi, Bo; Gao, Jian; Chu, Meilin; Fan, Wenlu; Yi, Meihui; Xu, Hong; Mao, Chun

    2017-07-18

    A simple and accurate immune sensor for quantitative detection of α-Fetoprotein (AFP) was developed based on the immobilization of antigen on the surface of Hep-PGA-PPy nanoparticles modified glassy carbon electrodes (GCE). The obtained Hep-PGA-PPy nanoparticles were characterized by fourier transform infrared (FT-IR) spectra and transmission electron microscopy (TEM). And the blood compatibility of Hep-PGA-PPy nanoparticles was investigated by in vitro coagulation tests, hemolysis assay and whole blood adhesion tests. Combining the conductive property of polypyrrole (PPy) and the biocompatibility of heparin (Hep), the Hep-PGA-PPy nanoparticles could improve not only the anti-biofouling effect the electrode, but also improved the electrochemical properties of the immune sensor. Under optimal conditions, the proposed immune sensor could detect AFP in a linear range from 0.1 to 100 ng mL -1 with a detection limit of 0.099 ng mL -1 at the signal-to-noise ratio of 3, and it also possessed good reproducibility and storage stability. Furthermore, the detection of AFP in five human blood samples also showed satisfactory accuracy with low relative errors. Thus, the developed immune sensor which showed acceptable reproducibility, selectivity, stability and accuracy could be potentially used for the detection of whole blood samples directly. Copyright © 2017. Published by Elsevier B.V.

  8. Novel Filtration Markers for GFR Estimation

    PubMed Central

    Inker, Lesley A.; Coresh, Josef; Levey, Andrew S.; Eckfeldt, John H.

    2017-01-01

    Creatinine-based glomerular filtration rate estimation (eGFRcr) has been improved and refined since the 1970s through both the Modification of Diet in Renal Disease (MDRD) Study equation in 1999 and the CKD Epidemiology Collaboration (CKD-EPI) equation in 2009, with current clinical practice dependent primarily on eGFR for accurate assessment of GFR. However, researchers and clinicians have recognized limitations of relying on creatinine as the only filtration marker, which can lead to inaccurate GFR estimates in certain populations due to the influence of non-GFR determinants of serum or plasma creatinine. Therefore, recent literature has proposed incorporation of multiple serum or plasma filtration markers into GFR estimation to improve precision and accuracy and decrease the impact of non-GFR determinants for any individual biomarker. To this end, the CKD-EPI combined creatinine-cystatin C equation (eGFRcr-cys) was developed in 2012 and demonstrated superior accuracy to equations relying on creatinine or cystatin C alone (eGFRcr or eGFRcys). Now, the focus has broadened to include additional novel filtration markers to further refine and improve GFR estimation. Beta-2-microglobulin (B2M) and beta-trace-protein (BTP) are two filtration markers with established assays that have been proposed as candidates for improving both GFR estimation and risk prediction. GFR estimating equations based on B2M and BTP have been developed and validated, with the CKD-EPI combined BTP-B2M equation (eGFRBTP-B2M) demonstrating similar performance to eGFR and eGFR. Additionally, several studies have demonstrated that both B2M and BTP are associated with outcomes in CKD patients, including cardiovascular events, ESRD and mortality. This review will primarily focus on these two biomarkers, and will highlight efforts to identify additional candidate biomarkers through metabolomics-based approaches. PMID:29333147

  9. Assay of lovastatin containing dietary supplement by LC-MS/MS under MRM condition.

    PubMed

    Di Donna, Leonardo; Bartella, Lucia; Napoli, Anna; Sindona, Giovanni; Mazzotti, Fabio

    2018-05-16

    Monacolin K, the active ingredient present in dietary supplement, is a nutraceutical whose health benefits have been widely documented. A fast approach for the assay of lovastatin in both form, lactone and acid, by mass spectrometry is presented. The quantitative assay is carried out by HPLC-MS/MS using the multiple reaction monitoring (MRM) mode and simvastatin and pravastatin as internal standards. The accuracy values ranged from 97 to 101%; the analytical parameters values of LOQ, LOD, recovery and reproducibility, were calculated analyzing fortified samples, confirming the reliability of the proposed approach. This article is protected by copyright. All rights reserved.

  10. Detection of Cytomegalovirus (CMV) DNA in EDTA Whole-Blood Samples: Evaluation of the Quantitative artus CMV LightCycler PCR Kit in Conjunction with Automated Sample Preparation▿

    PubMed Central

    Michelin, Birgit D. A.; Hadžisejdić, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blaženka; Marth, Egon; Kessler, Harald H.

    2008-01-01

    Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within ±0.5 log10 unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay. PMID:18272703

  11. Detection of cytomegalovirus (CMV) DNA in EDTA whole-blood samples: evaluation of the quantitative artus CMV LightCycler PCR kit in conjunction with automated sample preparation.

    PubMed

    Michelin, Birgit D A; Hadzisejdic, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blazenka; Marth, Egon; Kessler, Harald H

    2008-04-01

    Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.

  12. A rapid and efficient branched DNA hybridization assay to titer lentiviral vectors.

    PubMed

    Nair, Ayyappan; Xie, Jinger; Joshi, Sarasijam; Harden, Paul; Davies, Joan; Hermiston, Terry

    2008-11-01

    A robust assay to titer lentiviral vectors is imperative to qualifying their use in drug discovery, target validation and clinical applications. In this study, a novel branched DNA based hybridization assay was developed to titer lentiviral vectors by quantifying viral RNA genome copy numbers from viral lysates without having to purify viral RNA, and this approach was compared with other non-functional (p24 protein ELISA and viral RT-qPCR) and a functional method (reporter gene expression) used commonly. The RT-qPCR method requires purification of viral RNA and the accuracy of titration therefore depends on the efficiency of purification; this requirement is ameliorated in the hybridization assay as RNA is measured directly in viral lysates. The present study indicates that the hybridization based titration assay performed on viral lysates was more accurate and has additional advantages of being rapid, robust and not dependent on transduction efficiency in different cell types.

  13. Development and evaluation of a novel LAMP assay for the diagnosis of Cutaneous and Visceral Leishmaniasis.

    PubMed

    Adams, Emily Rebecca; Schoone, Gerard; Versteeg, Inge; Gomez, Maria Adelaida; Diro, Ermias; Mori, Yasuyoshi; Perlee, Desiree; Downing, Tim; Saravia, Nancy; Assaye, Ashenafi; Hailu, Asrat; Albertini, Audrey; Ndung'u, Joseph Mathu; Schallig, Henk

    2018-04-25

    A novel Pan-Leishmania LAMP assay was developed for diagnosis of Cutaneous and Visceral Leishmaniasis (CL & VL) which can be used in near-patient settings. Primers were designed on the 18S rDNA and the conserved region of minicircle kDNA selected on the basis of high copy number. LAMP assays were evaluated for CL in a prospective cohort trial of 105 patients in South-West Colombia. Lesion swab samples from CL suspects were collected and tested using LAMP and compared to a composite reference of microscopy AND/OR culture to calculate diagnostic accuracy. LAMP assays were tested on 50 VL suspected patients from Ethiopia, including whole blood, peripheral blood mononuclear cells, and buffy coat. Diagnostic accuracy was calculated against a reference standard of microscopy of splenic or bone marrow aspirates. To calculate analytical specificity 100 clinical samples and isolates with fever causing pathogens including malaria, arboviruses and bacterial infections were tested. The LAMP assay had a sensitivity of 95% (95% CI: 87.2% - 98.5 %) and a specificity of 86% (95% CI: 67.3% -95.9 %) for the diagnosis of CL. On VL suspects the sensitivity was 92% (95% CI: 74.9 - 99.1%) and specificity of 100% (95% CI: 85.8-100%) in whole blood. For CL, LAMP is a sensitive tool for diagnosis and requires less equipment, time and expertise than alternative CL diagnostics. For VL, LAMP is sensitive using a minimally invasive sample as compared to the gold standard. The analytical specificity was 100%. Copyright © 2018 Adams et al.

  14. Data transformation methods for multiplexed assays

    DOEpatents

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2013-07-23

    Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.

  15. One or two serological assay testing strategy for diagnosis of HBV and HCV infection? The use of predictive modelling.

    PubMed

    Parry, John V; Easterbrook, Philippa; Sands, Anita R

    2017-11-01

    Initial serological testing for chronic hepatitis B virus (HBV) and hepatitis C virus (HCV) infection is conducted using either rapid diagnostic tests (RDT) or laboratory-based enzyme immunoassays (EIA)s for detection of hepatitis B surface antigen (HBsAg) or antibodies to HCV (anti-HCV), typically on serum or plasma specimens and, for certain RDTs, capillary whole blood. WHO recommends the use of standardized testing strategies - defined as a sequence of one or more assays to maximize testing accuracy while simplifying the testing process and ideally minimizing cost. Our objective was to examine the diagnostic outcomes of a one- versus two-assay serological testing strategy. These data were used to inform recommendations in the 2017 WHO Guidelines on hepatitis B and C testing. Few published studies have compared diagnostic outcomes for one-assay versus two-assay serological testing strategies for HBsAg and anti-HCV. Therefore, the principles of Bayesian statistics were used to conduct a modelling exercise to examine the outcomes of a one-assay versus two-assay testing strategy when applied to a hypothetical population of 10,000 individuals. The resulting model examined the diagnostic outcomes (true and false positive diagnoses; true and false negative diagnoses; positive and negative predictive values as a function of prevalence; and total tests required) for both one-assay and two-assay testing strategies. The performance characteristics assumed for assays used within the testing strategies were informed by WHO prequalification assessment findings and systematic reviews for diagnostic accuracy studies. Each of the presumptive testing strategies (one-assay or two-assay) was modelled at varying prevalences of HBsAg (10%, 2% and 0.4%) and of anti-HCV (40%, 10%, 2% and 0.4%), aimed at representing the range of testing populations typically encountered in WHO Member States. When the two-assay testing strategy was considered, the model assumed the independence of the two assays. Modeling demonstrated that applying a single assay (HBsAg or anti-HCV), even with high specificity (99%), may result in considerable numbers of false positive diagnoses and low positive predictive values (PPV), particularly in lower prevalence settings. Even at very low prevalences shifting to a two-assay testing strategy would result in a PPV approaching 1.0. When test sensitivity is high (>99%) false negative reactions are rare at all but the highest prevalences; but a two-test strategy might yield more false negative diagnoses. The order in which the tests are used has no impact on the overall accuracy of a two-assay strategy though it may impact the total number of tests needed to complete the diagnostic strategy, incurring added cost and complexity. HBsAg assays may have a low sensitivity (<90%), and result in large numbers of false negative diagnoses, particularly in high prevalence settings, which would be exacerbated in the two-assay testing strategy. In contrast, most anti-HCV assays have high sensitivity and lead to fewer false negative results, both in the one-assay and two-assay testing strategies. At prevalences ≤2% the number of tests needed using a second assay was nearly always small, at <300 per 10,000 individuals tested, making sustainability of a second assay uncertain in such a setting. A key public health objective of an effective testing strategy is to identify all individuals who would benefit from treatment. Therefore, a strategy that prioritizes a high NPV (minimal false negatives) may be acceptable even if the PPV is suboptimal (some false positives) as the implementation of such a public health programme must also take account of other factors such as costs, feasibility, impact on testing uptake and linkage to care, and consequences of a false-positive test. This rationale informed the development of the WHO Viral Hepatitis Testing Guidelines, with a conditional recommendation for a one-assay serological testing strategy in most testing settings and populations (≥0.4% prevalence in population tested). A one-test strategy results in few failures to diagnose infection and, although it is associated under most assumptions with a sub-optimal PPV, benefits include greater simplicity, easier implementation, lower costs and better feasibility, uptake and linkage to care. Furthermore, prior to antiviral therapy all those diagnosed either HBsAg or anti-HCV positive will require confirmation of viræmia, preventing unnecessary treatment of those who may be false positive on serology. For HBsAg, in low-prevalence settings (≤0.4%), a second recommendation was made to consider a two-assay testing strategy, using a confirmatory neutralization step or a second different HBsAg assay.

  16. Bringing influenza vaccines into the 21st century

    PubMed Central

    Settembre, Ethan C; Dormitzer, Philip R; Rappuoli, Rino

    2014-01-01

    The recent H7N9 influenza outbreak in China highlights the need for influenza vaccine production systems that are robust and can quickly generate substantial quantities of vaccines that target new strains for pandemic and seasonal immunization. Although the influenza vaccine system, a public-private partnership, has been effective in providing vaccines, there are areas for improvement. Technological advances such as mammalian cell culture production and synthetic vaccine seeds provide a means to increase the speed and accuracy of targeting new influenza strains with mass-produced vaccines by dispensing with the need for egg isolation, adaptation, and reassortment of vaccine viruses. New influenza potency assays that no longer require the time-consuming step of generating sheep antisera could further speed vaccine release. Adjuvants that increase the breadth of the elicited immune response and allow dose sparing provide an additional means to increase the number of available vaccine doses. Together these technologies can improve the influenza vaccination system in the near term. In the longer term, disruptive technologies, such as RNA-based flu vaccines and ‘universal’ flu vaccines, offer a promise of a dramatically improved influenza vaccine system. PMID:24378716

  17. Bringing influenza vaccines into the 21st century.

    PubMed

    Settembre, Ethan C; Dormitzer, Philip R; Rappuoli, Rino

    2014-01-01

    The recent H7N9 influenza outbreak in China highlights the need for influenza vaccine production systems that are robust and can quickly generate substantial quantities of vaccines that target new strains for pandemic and seasonal immunization. Although the influenza vaccine system, a public-private partnership, has been effective in providing vaccines, there are areas for improvement. Technological advances such as mammalian cell culture production and synthetic vaccine seeds provide a means to increase the speed and accuracy of targeting new influenza strains with mass-produced vaccines by dispensing with the need for egg isolation, adaptation, and reassortment of vaccine viruses. New influenza potency assays that no longer require the time-consuming step of generating sheep antisera could further speed vaccine release. Adjuvants that increase the breadth of the elicited immune response and allow dose sparing provide an additional means to increase the number of available vaccine doses. Together these technologies can improve the influenza vaccination system in the near term. In the longer term, disruptive technologies, such as RNA-based flu vaccines and 'universal' flu vaccines, offer a promise of a dramatically improved influenza vaccine system.

  18. Absorbance and fluorometric sensing with capillary wells microplates.

    PubMed

    Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian; Liew, Oi Wah; Ng, Tuck Wah

    2010-12-01

    Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly in the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.

  19. Investigation of the interpolation method to improve the distributed strain measurement accuracy in optical frequency domain reflectometry systems.

    PubMed

    Cui, Jiwen; Zhao, Shiyuan; Yang, Di; Ding, Zhenyang

    2018-02-20

    We use a spectrum interpolation technique to improve the distributed strain measurement accuracy in a Rayleigh-scatter-based optical frequency domain reflectometry sensing system. We demonstrate that strain accuracy is not limited by the "uncertainty principle" that exists in the time-frequency analysis. Different interpolation methods are investigated and used to improve the accuracy of peak position of the cross-correlation and, therefore, improve the accuracy of the strain. Interpolation implemented by padding zeros on one side of the windowed data in the spatial domain, before the inverse fast Fourier transform, is found to have the best accuracy. Using this method, the strain accuracy and resolution are both improved without decreasing the spatial resolution. The strain of 3 μϵ within the spatial resolution of 1 cm at the position of 21.4 m is distinguished, and the measurement uncertainty is 3.3 μϵ.

  20. Assays for estimating HIV incidence: updated global market assessment and estimated economic value.

    PubMed

    Morrison, Charles S; Homan, Rick; Mack, Natasha; Seepolmuang, Pairin; Averill, Megan; Taylor, Jamilah; Osborn, Jennifer; Dailey, Peter; Parkin, Neil; Ongarello, Stefano; Mastro, Timothy D

    2017-11-01

    Accurate incidence estimates are needed to characterize the HIV epidemic and guide prevention efforts. HIV Incidence assays are cost-effective laboratory assays that provide incidence estimates from cross-sectional surveys. We conducted a global market assessment of HIV incidence assays under three market scenarios and estimated the economic value of improved incidence assays. We interviewed 27 stakeholders, and reviewed journal articles, working group proceedings, and manufacturers' sales figures. We determined HIV incidence assay use in 2014, and estimated use in 2015 to 2017 and in 5 to 10-years under three market scenarios, as well as the cost of conducting national and key population surveys using an HIV incidence assay with improved performance. Global 2014 HIV incidence assay use was 308,900 tests, highest in Asia and mostly for case- and population-based surveillance. Estimated 2015 to 2017 use was 94,475 annually, with declines due to China and the United States discontinuing incidence assay use for domestic surveillance. Annual projected 5 to 10 year use under scenario 1 - no change in technology - was 94,475. For scenario 2 - a moderately improved incidence assay - projected annual use was 286,031. Projected annual use for scenario 3 - game-changing technologies with an HIV incidence assay part of (a) standard confirmatory testing, and (b) standard rapid testing, were 500,000 and 180 million, respectively. As HIV incidence assay precision increases, decreased sample sizes required for incidence estimation resulted in $5 to 23 million annual reductions in survey costs and easily offset the approximately $3 million required to develop a new assay. Improved HIV incidence assays could substantially reduce HIV incidence estimation costs. Continued development of HIV incidence assays with improved performance is required to realize these cost benefits. © 2017 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  1. Improved detection of equine antibodies against Sarcocystis neurona using polyvalent ELISAs based on the parasite SnSAG surface antigens.

    PubMed

    Yeargan, Michelle R; Howe, Daniel K

    2011-02-28

    Equine protozoal myeloencephalitis (EPM) is a common neurologic disease of horses that is caused by the apicomplexan pathogen Sarcocystis neurona. To help improve serologic diagnosis of S. neurona infection, we have modified existing enzyme-linked immunosorbent assays (ELISAs) based on the immunogenic parasite surface antigens SnSAG2, SnSAG3, and SnSAG4 to make the assays polyvalent, thereby circumventing difficulties associated with parasite antigenic variants and diversity in equine immune responses. Two approaches were utilized to achieve polyvalence: (1) mixtures of the individual recombinant SnSAGs (rSnSAGs) were included in single ELISAs; (2) a collection of unique SnSAG chimeras that fused protein domains from different SnSAG surface antigens into a single recombinant protein were generated for use in the ELISAs. These new assays were assessed using a defined sample set of equine sera and cerebrospinal fluids (CSFs) that had been characterized by Western blot and/or were from confirmed EPM horses. While all of the polyvalent ELISAs performed relatively well, the highest sensitivity and specificity (100%/100%) were achieved with assays containing the rSnSAG4/2 chimera (Domain 1 of SnSAG4 fused to SnSAG2) or using a mixture of rSnSAG3 and rSnSAG4. The rSnSAG4 antigen alone and the rSnSAG4/3 chimera (Domain 1 of SnSAG4 fused to Domain 2 of SnSAG3) exhibited the next best accuracy at 95.2% sensitivity and 100% specificity. Binding ratios and percent positivity (PP) ratios, determined by comparing the mean values for positive versus negative samples, showed that the most advantageous signal to noise ratios were provided by rSnSAG4 and the rSnSAG4/3 chimera. Collectively, our results imply that a polyvalent ELISA based on SnSAG4 and SnSAG3, whether as a cocktail of two proteins or as a single chimeric protein, can give optimal results in serologic testing of serum or CSF for the presence of antibodies against S. neurona. The use of polyvalent SnSAG ELISAs will enhance the reliability of serologic testing for S. neurona infection, which should lead to improved diagnosis of EPM. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Clinical Pharmacology Quality Assurance (CPQA) Program: Models for Longitudinal Analysis of Antiretroviral (ARV) Proficiency Testing for International Laboratories

    PubMed Central

    DiFrancesco, Robin; Rosenkranz, Susan L.; Taylor, Charlene R.; Pande, Poonam G.; Siminski, Suzanne M.; Jenny, Richard W.; Morse, Gene D.

    2013-01-01

    Among National Institutes of Health (NIH) HIV Research Networks conducting multicenter trials, samples from protocols that span several years are analyzed at multiple clinical pharmacology laboratories (CPLs) for multiple antiretrovirals (ARV). Drug assay data are, in turn, entered into study-specific datasets that are used for pharmacokinetic analyses, merged to conduct cross-protocol pharmacokinetic analysis and integrated with pharmacogenomics research to investigate pharmacokinetic-pharmacogenetic associations. The CPLs participate in a semi-annual proficiency testing (PT) program implemented by the Clinical Pharmacology Quality Assurance (CPQA) program. Using results from multiple PT rounds, longitudinal analyses of recovery are reflective of accuracy and precision within/across laboratories. The objectives of this longitudinal analysis of PT across multiple CPLs were to develop and test statistical models that longitudinally: (1)assess the precision and accuracy of concentrations reported by individual CPLs; (2)determine factors associated with round-specific and long-term assay accuracy, precision and bias using a new regression model. A measure of absolute recovery is explored as a simultaneous measure of accuracy and precision. Overall, the analysis outcomes assured 97% accuracy (±20% of the final target concentration of all (21)drug concentration results reported for clinical trial samples by multiple CPLs).Using the CLIA acceptance of meeting criteria for ≥2/3 consecutive rounds, all ten laboratories that participated in three or more rounds per analyte maintained CLIA proficiency. Significant associations were present between magnitude of error and CPL (Kruskal Wallis [KW]p<0.001), and ARV (KW p<0.001). PMID:24052065

  3. Microbiological assay for the determination of meropenem in pharmaceutical dosage form.

    PubMed

    Mendez, Andreas S L; Weisheimer, Vanessa; Oppe, Tércio P; Steppe, Martin; Schapoval, Elfrides E S

    2005-04-01

    Meropenem is a highly active carbapenem antibiotic used in the treatment of a wide range of serious infections. The present work reports a microbiological assay, applying the cylinder-plate method, for the determination of meropenem in powder for injection. The validation method yielded good results and included linearity, precision, accuracy and specificity. The assay is based on the inhibitory effect of meropenem upon the strain of Micrococcus luteus ATCC 9341 used as the test microorganism. The results of assay were treated statistically by analysis of variance (ANOVA) and were found to be linear (r=0.9999) in the range of 1.5-6.0 microg ml(-1), precise (intra-assay: R.S.D.=0.29; inter-assay: R.S.D.=0.94) and accurate. A preliminary stability study of meropenem was performed to show that the microbiological assay is specific for the determination of meropenem in the presence of its degradation products. The degraded samples were also analysed by the HPLC method. The proposed method allows the quantitation of meropenem in pharmaceutical dosage form and can be used for the drug analysis in routine quality control.

  4. Development and validation of qualitative SYBR®Green real-time PCR for detection and discrimination of Listeria spp. and Listeria monocytogenes.

    PubMed

    Barbau-Piednoir, Elodie; Botteldoorn, Nadine; Yde, Marc; Mahillon, Jacques; Roosens, Nancy H

    2013-05-01

    A combination of four qualitative SYBR®Green qPCR screening assays targeting two levels of discrimination: Listeria genus (except Listeria grayi) and Listeria monocytogenes, is presented. These assays have been developed to be run simultaneously using the same polymerase chain reaction (PCR) programme. The paper also proposes a new validation procedure to specifically validate qPCR assays applied to food microbiology according to two guidelines: the ISO 22118 norm and the "Definition of minimum performance requirements for analytical methods of GMO testing". The developed assays target the iap, prs and hlyA genes that belong to or neighbour the virulence cluster of Listeria spp. The selected primers were designed to amplify short fragments (60 to 103 bp) in order to obtain optimal PCR efficiency (between 97 and 107 % efficiency). The limit of detection of the SYBR®Green qPCR assays is two to five copies of target genes per qPCR reaction. These assays are highly accurate (98.08 and 100 % accuracy for the Listeria spp. and L. monocytogenes assays, respectively).

  5. Development and accuracy of quantitative real-time polymerase chain reaction assays for detection and quantification of enterotoxigenic Escherichia coli (ETEC) heat labile and heat stable toxin genes in travelers' diarrhea samples.

    PubMed

    Youmans, Bonnie P; Ajami, Nadim J; Jiang, Zhi-Dong; Petrosino, Joseph F; DuPont, Herbert L; Highlander, Sarah K

    2014-01-01

    Enterotoxigenic Escherichia coli (ETEC), the leading bacterial pathogen of travelers' diarrhea, is routinely detected by an established DNA hybridization protocol that is neither sensitive nor quantitative. Quantitative real-time polymerase chain reaction (qPCR) assays that detect the ETEC toxin genes eltA, sta1, and sta2 in clinical stool samples were developed and tested using donor stool inoculated with known quantities of ETEC bacteria. The sensitivity of the qPCR assays is 89%, compared with 22% for the DNA hybridization assay, and the limits of detection are 10,000-fold lower than the DNA hybridization assays performed in parallel. Ninety-three clinical stool samples, previously characterized by DNA hybridization, were tested using the new ETEC qPCR assays. Discordant toxin profiles were observed for 22 samples, notably, four samples originally typed as ETEC negative were ETEC positive. The qPCR assays are unique in their sensitivity and ability to quantify the three toxin genes in clinical stool samples.

  6. Real-time PCR assay is superior to other methods for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran.

    PubMed

    Molla Kazemiha, Vahid; Bonakdar, Shahin; Amanzadeh, Amir; Azari, Shahram; Memarnejadian, Arash; Shahbazi, Shirin; Shokrgozar, Mohammad Ali; Mahdian, Reza

    2016-08-01

    Mycoplasmas are the most important contaminants of cell cultures throughout the world. They are considered as a major problem in biological studies and biopharmaceutical economic issues. In this study, our aim was to find the best standard technique as a rapid method with high sensitivity, specificity and accuracy for the detection of mycoplasma contamination in the cell lines of the National Cell Bank of Iran. Thirty cell lines suspected to mycoplasma contamination were evaluated by five different techniques including microbial culture, indirect DNA DAPI staining, enzymatic mycoalert(®) assay, conventional PCR and real-time PCR. Five mycoplasma-contaminated cell lines were assigned as positive controls and five mycoplasma-free cell lines as negative controls. The enzymatic method was performed using the mycoalert(®) mycoplasma detection kit. Real-time PCR technique was conducted by PromoKine diagnostic kits. In the conventional PCR method, mycoplasma genus-specific primers were designed to analyze the sequences based on a fixed and common region on 16S ribosomal RNA with PCR product size of 425 bp. Mycoplasma contamination was observed in 60, 56.66, 53.33, 46.66 and 33.33 % of 30 different cell cultures by real-time PCR, PCR, enzymatic mycoalert(®), indirect DNA DAPI staining and microbial culture methods, respectively. The analysis of the results of the different methods showed that the real-time PCR assay was superior the other methods with the sensitivity, specificity, accuracy, predictive value of positive and negative results of 100 %. These values were 94.44, 100, 96.77, 100 and 92.85 % for the conventional PCR method, respectively. Therefore, this study showed that real-time PCR and PCR assays based on the common sequences in the 16S ribosomal RNA are reliable methods with high sensitivity, specificity and accuracy for detection of mycoplasma contamination in cell cultures and other biological products.

  7. Improved regulatory element prediction based on tissue-specific local epigenomic signatures

    PubMed Central

    He, Yupeng; Gorkin, David U.; Dickel, Diane E.; Nery, Joseph R.; Castanon, Rosa G.; Lee, Ah Young; Shen, Yin; Visel, Axel; Pennacchio, Len A.; Ren, Bing; Ecker, Joseph R.

    2017-01-01

    Accurate enhancer identification is critical for understanding the spatiotemporal transcriptional regulation during development as well as the functional impact of disease-related noncoding genetic variants. Computational methods have been developed to predict the genomic locations of active enhancers based on histone modifications, but the accuracy and resolution of these methods remain limited. Here, we present an algorithm, regulatory element prediction based on tissue-specific local epigenetic marks (REPTILE), which integrates histone modification and whole-genome cytosine DNA methylation profiles to identify the precise location of enhancers. We tested the ability of REPTILE to identify enhancers previously validated in reporter assays. Compared with existing methods, REPTILE shows consistently superior performance across diverse cell and tissue types, and the enhancer locations are significantly more refined. We show that, by incorporating base-resolution methylation data, REPTILE greatly improves upon current methods for annotation of enhancers across a variety of cell and tissue types. REPTILE is available at https://github.com/yupenghe/REPTILE/. PMID:28193886

  8. A cost effective 5΄ selective single cell transcriptome profiling approach with improved UMI design

    PubMed Central

    Arguel, Marie-Jeanne; LeBrigand, Kevin; Paquet, Agnès; Ruiz García, Sandra; Zaragosi, Laure-Emmanuelle; Waldmann, Rainer

    2017-01-01

    Abstract Single cell RNA sequencing approaches are instrumental in studies of cell-to-cell variability. 5΄ selective transcriptome profiling approaches allow simultaneous definition of the transcription start size and have advantages over 3΄ selective approaches which just provide internal sequences close to the 3΄ end. The only currently existing 5΄ selective approach requires costly and labor intensive fragmentation and cell barcoding after cDNA amplification. We developed an optimized 5΄ selective workflow where all the cell indexing is done prior to fragmentation. With our protocol, cell indexing can be performed in the Fluidigm C1 microfluidic device, resulting in a significant reduction of cost and labor. We also designed optimized unique molecular identifiers that show less sequence bias and vulnerability towards sequencing errors resulting in an improved accuracy of molecule counting. We provide comprehensive experimental workflows for Illumina and Ion Proton sequencers that allow single cell sequencing in a cost range comparable to qPCR assays. PMID:27940562

  9. Computer Vision Malaria Diagnostic Systems-Progress and Prospects.

    PubMed

    Pollak, Joseph Joel; Houri-Yafin, Arnon; Salpeter, Seth J

    2017-01-01

    Accurate malaria diagnosis is critical to prevent malaria fatalities, curb overuse of antimalarial drugs, and promote appropriate management of other causes of fever. While several diagnostic tests exist, the need for a rapid and highly accurate malaria assay remains. Microscopy and rapid diagnostic tests are the main diagnostic modalities available, yet they can demonstrate poor performance and accuracy. Automated microscopy platforms have the potential to significantly improve and standardize malaria diagnosis. Based on image recognition and machine learning algorithms, these systems maintain the benefits of light microscopy and provide improvements such as quicker scanning time, greater scanning area, and increased consistency brought by automation. While these applications have been in development for over a decade, recently several commercial platforms have emerged. In this review, we discuss the most advanced computer vision malaria diagnostic technologies and investigate several of their features which are central to field use. Additionally, we discuss the technological and policy barriers to implementing these technologies in low-resource settings world-wide.

  10. Diagnostic accuracy of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for the detection of antibodies against Neospora caninum in milk from dairy cows.

    PubMed

    Chatziprodromidou, I P; Apostolou, T

    2018-04-01

    The aim of the study was to estimate the sensitivity and specificity of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for detecting antibodies of Neospora caninum in dairy cows, in the absence of a gold standard. The study complies with STRADAS-paratuberculosis guidelines for reporting the accuracy of the test. We tried to apply Bayesian models that do not require conditional independence of the tests under evaluation, but as convergence problems appeared, we used Bayesian methodology, that does not assume conditional dependence of the tests. Informative prior probability distributions were constructed, based on scientific inputs regarding sensitivity and specificity of the IB test and the prevalence of disease in the studied populations. IB sensitivity and specificity were estimated to be 98.8% and 91.3%, respectively, while the respective estimates for ELISA were 60% and 96.7%. A sensitivity analysis, where modified prior probability distributions concerning IB diagnostic accuracy applied, showed a limited effect in posterior assessments. We concluded that ELISA can be used to screen the bulk milk and secondly, IB can be used whenever needed.

  11. The gallium melting-point standard: its application and evaluation for temperature measurements in the clinical laboratory.

    PubMed

    Bowers, G N; Inman, S R

    1977-01-01

    We are impressed with the ease and certainty of calibration electronic thermometers with thermistor probes to +/- 0.01 degree C at the gallium melting point, 29.771(4) degrees C. The IFCC reference method for measuring aspartate aminotransferase activity in serum was run at the reaction temperature of 29.771(4) degrees C. By constantly referencing to gallium as an integral part of the assay procedure, we determined the absolute reaction temperature to IPTS-68 (International Practical Temperature Scale of 1968) to +/- 0.02 degrees C. This unique temperature calibration standard near the center of the range of temperatures commonly used in the clinical laboratory is a valuable addition and can be expected to improve the accuracy of measurements, especially in clinical enzymology.

  12. A gold nanoparticles-based colorimetric test to detect single nucleotide polymorphisms for improvement of personalized therapy of psoriasis

    NASA Astrophysics Data System (ADS)

    Marsella, Alessandra; Valentini, Paola; Tarantino, Paolo; Congedo, Maurizio; Pompa, Pier Paolo

    2016-04-01

    We report a simple, rapid and low-cost test, based on gold nanoparticles, for the naked-eye colorimetric detection of a signature of single nucleotide polymorphisms (SNPs) relevant for the personalized medicine of psoriasis patients. We validated the colorimetric assay on real-world DNA samples from a cohort of 30 psoriasis patients and we compared the results, in double-blind, with those obtained with two state-of-the-art instrumental techniques, namely reverse dot blotting and direct sequencing, finding 100% agreement. We demonstrated high accuracy, sensitivity and specificity of the colorimetric test that can be easily adapted for the genotypization of different SNPs, important for the pharmacogenomics of various diseases, and in other fields, such as food traceability and population structure analysis.

  13. The EpiOcular Eye Irritation Test (EIT) for hazard identification and labelling of eye irritating chemicals: protocol optimisation for solid materials and the results after extended shipment.

    PubMed

    Kaluzhny, Yulia; Kandárová, Helena; Handa, Yuki; DeLuca, Jane; Truong, Thoa; Hunter, Amy; Kearney, Paul; d'Argembeau-Thornton, Laurence; Klausner, Mitchell

    2015-05-01

    The 7th Amendment to the EU Cosmetics Directive and the EU REACH Regulation have reinforced the need for in vitro ocular test methods. Validated in vitro ocular toxicity tests that can predict the human response to chemicals, cosmetics and other consumer products are required for the safety assessment of materials that intentionally, or inadvertently, come into contact with the eye. The EpiOcular Eye Irritation Test (EIT), which uses the normal human cell-based EpiOcular™ tissue model, was developed to address this need. The EpiOcular-EIT is able to discriminate, with high sensitivity and accuracy, between ocular irritant/corrosive materials and those that require no labelling. Although the original EpiOcular-EIT protocol was successfully pre-validated in an international, multicentre study sponsored by COLIPA (the predecessor to Cosmetics Europe), data from two larger studies (the EURL ECVAM-COLIPA validation study and an independent in-house validation at BASF SE) resulted in a sensitivity for the protocol for solids that was below the acceptance criteria set by the Validation Management Group (VMG) for eye irritation, and indicated the need for improvement of the assay's sensitivity for solids. By increasing the exposure time for solid materials from 90 minutes to 6 hours, the optimised EpiOcular-EIT protocol achieved 100% sensitivity, 68.4% specificity and 84.6% accuracy, thereby meeting all the acceptance criteria set by the VMG. In addition, to satisfy the needs of Japan and the Pacific region, the EpiOcular-EIT method was evaluated for its performance after extended shipment and storage of the tissues (4-5 days), and it was confirmed that the assay performs with similar levels of sensitivity, specificity and reproducibility in these circumstances. 2015 FRAME.

  14. Use of response surface methodology for development of new microwell-based spectrophotometric method for determination of atrovastatin calcium in tablets

    PubMed Central

    2012-01-01

    Background Response surface methodology by Box–Behnken design employing the multivariate approach enables substantial improvement in the method development using fewer experiments, without wastage of large volumes of organic solvents, which leads to high analysis cost. This methodology has not been employed for development of a method for analysis of atorvastatin calcium (ATR-Ca). Results The present research study describes the use of in optimization and validation of a new microwell-based UV-Visible spectrophotometric method of for determination of ATR-Ca in its tablets. By the use of quadratic regression analysis, equations were developed to describe the behavior of the response as simultaneous functions of the selected independent variables. Accordingly, the optimum conditions were determined which included concentration of 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), time of reaction and temperature. The absorbance of the colored-CT complex was measured at 460 nm by microwell-plate absorbance reader. The method was validated, in accordance with ICH guidelines for accuracy, precision, selectivity and linearity (r² = 0.9993) over the concentration range of 20–200 μg/ml. The assay was successfully applied to the analysis of ATR-Ca in its pharmaceutical dosage forms with good accuracy and precision. Conclusion The assay described herein has great practical value in the routine analysis of ATR-Ca in quality control laboratories, as it has high throughput property, consumes minimum volume of organic solvent thus it offers the reduction in the exposures of the analysts to the toxic effects of organic solvents, environmentally friendly "Green" approach) and reduction in the analysis cost by 50-fold. PMID:23146143

  15. Use of Whole-Genome Phylogeny and Comparisons for Development of a Multiplex PCR Assay To Identify Sequence Type 36 Vibrio parahaemolyticus.

    PubMed

    Whistler, Cheryl A; Hall, Jeffrey A; Xu, Feng; Ilyas, Saba; Siwakoti, Puskar; Cooper, Vaughn S; Jones, Stephen H

    2015-06-01

    Vibrio parahaemolyticus sequence type 36 (ST36) strains that are native to the Pacific Ocean have recently caused multistate outbreaks of gastroenteritis linked to shellfish harvested from the Atlantic Ocean. Whole-genome comparisons of 295 genomes of V. parahaemolyticus, including several traced to northeastern U.S. sources, were used to identify diagnostic loci, one putatively encoding an endonuclease (prp), and two others potentially conferring O-antigenic properties (cps and flp). The combination of all three loci was present in only one clade of closely related strains of ST36, ST59, and one additional unknown sequence type. However, each locus was also identified outside this clade, with prp and flp occurring in only two nonclade isolates and cps in four. Based on the distribution of these loci in sequenced genomes, prp identified clade strains with >99% accuracy, but the addition of one more locus increased accuracy to 100%. Oligonucleotide primers targeting prp and cps were combined in a multiplex PCR method that defines species using the tlh locus and determines the presence of both the tdh and trh hemolysin-encoding genes, which are also present in ST36. Application of the method in vitro to a collection of 94 clinical isolates collected over a 4-year period in three northeastern U.S. states and 87 environmental isolates revealed that the prp and cps amplicons were detected only in clinical isolates identified as belonging to the ST36 clade and in no environmental isolates from the region. The assay should improve detection and surveillance, thereby reducing infections. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  16. Comparison of an IgG-Specific Enzyme-Linked Immunosorbent Assay Cutoff of 0.4 Versus 0.8 and 1.0 Optical Density Units for Heparin-Induced Thrombocytopenia.

    PubMed

    Ritchie, Brianne M; Connors, Jean M; Sylvester, Katelyn W

    2017-04-01

    Previous studies have demonstrated optimized diagnostic accuracy in utilizing higher antiheparin-platelet factor 4 (PF4) enzyme-linked immunosorbent assay (ELISA) optical density (OD) thresholds for diagnosing heparin-induced thrombocytopenia (HIT). We describe the incidence of positive serotonin release assay (SRA) results, as well as performance characteristics, for antiheparin-PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units in the diagnosis of HIT at our institution. Following institutional review board approval, we conducted a single-center retrospective chart review on adult inpatients with a differential diagnosis of HIT evaluated by both antiheparin-PF4 ELISA and SRA from 2012 to 2014. The major endpoints were to assess incidence of positive SRA results, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy at antiheparin-PF4 ELISA values ≥0.4 OD units when compared to values ≥0.8 and ≥1.0 OD units. Clinical characteristics, including demographics, laboratory values, clinical and safety outcomes, length of stay, and mortality, were collected. A total of 140 patients with 140 antiheparin-PF4 ELISA and SRA values were evaluated, of which 23 patients were SRA positive (16.4%) and 117 patients were SRA negative (83.6%). We identified a sensitivity of 91.3% versus 82.6% and 73.9%, specificity of 61.5% versus 87.2% and 91.5%, PPV of 31.8% versus 55.9% and 63.0%, NPV of 97.3% versus 96.2% and 94.7%, and accuracy of 66.4% versus 86.4% and 88.6% at antiheparin-PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units, respectively. Our study suggests an increased antiheparin-PF4 ELISA threshold of 0.8 or 1.0 OD units enhances specificity, PPV, and accuracy while maintaining NPV with decreased sensitivity.

  17. Diagnostic accuracy of Xpert MTB/RIF assay for musculoskeletal tuberculosis: a meta-analysis.

    PubMed

    Wen, Hai; Li, Pengzhi; Ma, Hong; Lv, Guohua

    2017-01-01

    Xpert MTB/RIF assay, a rapid and automated real-time nucleic acid amplification test, has been reported for the diagnosis of musculoskeletal tuberculosis (TB) in current years. This meta-analysis aims to determine the diagnostic accuracy of Xpert for the detection of musculoskeletal TB and rifampicin (RIF) resistance. We searched PubMed, Embase, China National Knowledge Infrastructure, and Wanfang for original articles published up to 1st June 2017 to identify studies in which the Xpert assay was applied to diagnose musculoskeletal TB. Pooled estimates were calculated using a random-effects model or a fixed-effects model according to heterogeneity. Summary receiver operating characteristic curves and the area under the curve (AUC) were used to summarize overall diagnostic performance. Deeks' test was performed to evaluate potential publication bias. Twelve studies were identified with a pooled sensitivity and specificity of respectively 0.81 (95% confidence interval [CI] 0.78-0.83) and 0.83 (95% CI 0.80-0.86) of Xpert for the diagnosis of musculoskeletal TB. Xpert was highly sensitive (0.89, 95% CI 0.79-0.95) and highly specific (0.96, 95% CI 0.92-0.98) in detecting RIF resistance. AUC (over 0.9) suggested a relatively high level of overall diagnostic accuracy of Xpert for detecting musculoskeletal TB and RIF resistance. Prevalence and reference standard were indicated to be sources of heterogeneity between studies. No publication bias was found. This study provides available evidence of the rapid and effective role of Xpert in diagnosing musculoskeletal TB and detecting RIF resistance.

  18. Genetic stock identification of Russian honey bees.

    PubMed

    Bourgeois, Lelania; Sheppard, Walter S; Sylvester, H Allen; Rinderer, Thomas E

    2010-06-01

    A genetic stock certification assay was developed to distinguish Russian honey bees from other European (Apis mellifera L.) stocks that are commercially produced in the United States. In total, 11 microsatellite and five single-nucleotide polymorphism loci were used. Loci were selected for relatively high levels of homogeneity within each group and for differences in allele frequencies between groups. A baseline sample consisted of the 18 lines of Russian honey bees released to the Russian Bee Breeders Association and bees from 34 queen breeders representing commercially produced European honey bee stocks. Suitability tests of the baseline sample pool showed high levels of accuracy. The probability of correct assignment was 94.2% for non-Russian bees and 93.3% for Russian bees. A neighbor-joining phenogram representing genetic distance data showed clear distinction of Russian and non-Russian honey bee stocks. Furthermore, a test of appropriate sample size showed a sample of eight bees per colony maximizes accuracy and consistency of the results. An additional 34 samples were tested as blind samples (origin unknown to those collecting data) to determine accuracy of individual assignment tests. Only one of these samples was incorrectly assigned. The 18 current breeding lines were represented among the 2009 blind sampling, demonstrating temporal stability of the genetic stock identification assay. The certification assay will be used through services provided by a service laboratory, by the Russian Bee Breeders Association to genetically certify their stock. The genetic certification will be used in conjunction with continued selection for favorable traits, such as honey production and varroa and tracheal mite resistance.

  19. Nanozyme-based bio-barcode assay for high sensitive and logic-controlled specific detection of multiple DNAs.

    PubMed

    Lin, Xiaodong; Liu, Yaqing; Tao, Zhanhui; Gao, Jinting; Deng, Jiankang; Yin, Jinjin; Wang, Shuo

    2017-08-15

    Since HCV and HIV share a common transmission path, high sensitive detection of HIV and HCV gene is of significant importance to improve diagnosis accuracy and cure rate at early stage for HIV virus-infected patients. In our investigation, a novel nanozyme-based bio-barcode fluorescence amplified assay is successfully developed for simultaneous detection of HIV and HCV DNAs with excellent sensitivity in an enzyme-free and label-free condition. Here, bimetallic nanoparticles, PtAu NPs , present outstanding peroxidase-like activity and act as barcode to catalyze oxidation of nonfluorescent substrate of amplex red (AR) into fluorescent resorufin generating stable and sensitive "Turn On" fluorescent output signal, which is for the first time to be integrated with bio-barcode strategy for fluorescence detection DNA. Furthermore, the provided strategy presents excellent specificity and can distinguish single-base mismatched mutant from target DNA. What interesting is that cascaded INHIBIT-OR logic gate is integrated with biosensors for the first time to distinguish individual target DNA from each other under logic function control, which presents great application in development of rapid and intelligent detection. Copyright © 2017. Published by Elsevier B.V.

  20. Dual-color Proteomic Profiling of Complex Samples with a Microarray of 810 Cancer-related Antibodies*

    PubMed Central

    Schröder, Christoph; Jacob, Anette; Tonack, Sarah; Radon, Tomasz P.; Sill, Martin; Zucknick, Manuela; Rüffer, Sven; Costello, Eithne; Neoptolemos, John P.; Crnogorac-Jurcevic, Tatjana; Bauer, Andrea; Fellenberg, Kurt; Hoheisel, Jörg D.

    2010-01-01

    Antibody microarrays have the potential to enable comprehensive proteomic analysis of small amounts of sample material. Here, protocols are presented for the production, quality assessment, and reproducible application of antibody microarrays in a two-color mode with an array of 1,800 features, representing 810 antibodies that were directed at 741 cancer-related proteins. In addition to measures of array quality, we implemented indicators for the accuracy and significance of dual-color detection. Dual-color measurements outperform a single-color approach concerning assay reproducibility and discriminative power. In the analysis of serum samples, depletion of high-abundance proteins did not improve technical assay quality. On the contrary, depletion introduced a strong bias in protein representation. In an initial study, we demonstrated the applicability of the protocols to proteins derived from urine samples. We identified differences between urine samples from pancreatic cancer patients and healthy subjects and between sexes. This study demonstrates that biomedically relevant data can be produced. As demonstrated by the thorough quality analysis, the dual-color antibody array approach proved to be competitive with other proteomic techniques and comparable in performance to transcriptional microarray analyses. PMID:20164060

  1. RENEB intercomparisons applying the conventional Dicentric Chromosome Assay (DCA).

    PubMed

    Oestreicher, Ursula; Samaga, Daniel; Ainsbury, Elizabeth; Antunes, Ana Catarina; Baeyens, Ans; Barrios, Leonardo; Beinke, Christina; Beukes, Philip; Blakely, William F; Cucu, Alexandra; De Amicis, Andrea; Depuydt, Julie; De Sanctis, Stefania; Di Giorgio, Marina; Dobos, Katalin; Dominguez, Inmaculada; Duy, Pham Ngoc; Espinoza, Marco E; Flegal, Farrah N; Figel, Markus; Garcia, Omar; Monteiro Gil, Octávia; Gregoire, Eric; Guerrero-Carbajal, C; Güçlü, İnci; Hadjidekova, Valeria; Hande, Prakash; Kulka, Ulrike; Lemon, Jennifer; Lindholm, Carita; Lista, Florigio; Lumniczky, Katalin; Martinez-Lopez, Wilner; Maznyk, Nataliya; Meschini, Roberta; M'kacher, Radia; Montoro, Alegria; Moquet, Jayne; Moreno, Mercedes; Noditi, Mihaela; Pajic, Jelena; Radl, Analía; Ricoul, Michelle; Romm, Horst; Roy, Laurence; Sabatier, Laure; Sebastià, Natividad; Slabbert, Jacobus; Sommer, Sylwester; Stuck Oliveira, Monica; Subramanian, Uma; Suto, Yumiko; Que, Tran; Testa, Antonella; Terzoudi, Georgia; Vral, Anne; Wilkins, Ruth; Yanti, LusiYanti; Zafiropoulos, Demetre; Wojcik, Andrzej

    2017-01-01

    Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.

  2. Simple Quantification of Pentosidine in Human Urine and Plasma by High-Performance Liquid Chromatography

    PubMed Central

    Lee, Ji Sang; Chung, Yoon-Sok; Chang, Sun Young

    2017-01-01

    Pentosidine is an advanced glycation end-product (AGE) and fluorescent cross-link compound. A simple high-performance liquid chromatographic (HPLC) method was developed for the detection and quantification of pentosidine in human urine and plasma. The mobile phase used a gradient system to improve separation of pentosidine from endogenous peaks, and chromatograms were monitored by fluorescent detector set at excitation and emission wavelengths of 328 and 378 nm, respectively. The retention time for pentosidine was 24.3 min and the lower limits of quantification (LLOQ) in human urine and plasma were 1 nM. The intraday assay precisions (coefficients of variation) were generally low and found to be in the range of 5.19–7.49% and 4.96–8.78% for human urine and plasma, respectively. The corresponding values of the interday assay precisions were 9.45% and 4.27%. Accuracies (relative errors) ranged from 87.9% to 115%. Pentosidine was stable in a range of pH solutions, human urine, and plasma. In summary, this HPLC method can be applied in future preclinical and clinical evaluation of pentosidine in the diabetic patients. PMID:29181026

  3. Random Forests Are Able to Identify Differences in Clotting Dynamics from Kinetic Models of Thrombin Generation.

    PubMed

    Arumugam, Jayavel; Bukkapatnam, Satish T S; Narayanan, Krishna R; Srinivasa, Arun R

    2016-01-01

    Current methods for distinguishing acute coronary syndromes such as heart attack from stable coronary artery disease, based on the kinetics of thrombin formation, have been limited to evaluating sensitivity of well-established chemical species (e.g., thrombin) using simple quantifiers of their concentration profiles (e.g., maximum level of thrombin concentration, area under the thrombin concentration versus time curve). In order to get an improved classifier, we use a 34-protein factor clotting cascade model and convert the simulation data into a high-dimensional representation (about 19000 features) using a piecewise cubic polynomial fit. Then, we systematically find plausible assays to effectively gauge changes in acute coronary syndrome/coronary artery disease populations by introducing a statistical learning technique called Random Forests. We find that differences associated with acute coronary syndromes emerge in combinations of a handful of features. For instance, concentrations of 3 chemical species, namely, active alpha-thrombin, tissue factor-factor VIIa-factor Xa ternary complex, and intrinsic tenase complex with factor X, at specific time windows, could be used to classify acute coronary syndromes to an accuracy of about 87.2%. Such a combination could be used to efficiently assay the coagulation system.

  4. Humanizing the zebrafish liver shifts drug metabolic profiles and improves pharmacokinetics of CYP3A4 substrates.

    PubMed

    Poon, Kar Lai; Wang, Xingang; Ng, Ashley S; Goh, Wei Huang; McGinnis, Claudia; Fowler, Stephen; Carney, Tom J; Wang, Haishan; Ingham, Phillip W

    2017-03-01

    Understanding and predicting whether new drug candidates will be safe in the clinic is a critical hurdle in pharmaceutical development, that relies in part on absorption, distribution, metabolism, excretion and toxicology studies in vivo. Zebrafish is a relatively new model system for drug metabolism and toxicity studies, offering whole organism screening coupled with small size and potential for high-throughput screening. Through toxicity and absorption analyses of a number of drugs, we find that zebrafish is generally predictive of drug toxicity, although assay outcomes are influenced by drug lipophilicity which alters drug uptake. In addition, liver microsome assays reveal specific differences in metabolism of compounds between human and zebrafish livers, likely resulting from the divergence of the cytochrome P450 superfamily between species. To reflect human metabolism more accurately, we generated a transgenic "humanized" zebrafish line that expresses the major human phase I detoxifying enzyme, CYP3A4, in the liver. Here, we show that this humanized line shows an elevated metabolism of CYP3A4-specific substrates compared to wild-type zebrafish. The generation of this first described humanized zebrafish liver suggests such approaches can enhance the accuracy of the zebrafish model for toxicity prediction.

  5. Performance of commercial platforms for rapid genotyping of polymorphisms affecting warfarin dose.

    PubMed

    King, Cristi R; Porche-Sorbet, Rhonda M; Gage, Brian F; Ridker, Paul M; Renaud, Yannick; Phillips, Michael S; Eby, Charles

    2008-06-01

    Initiation of warfarin therapy is associated with bleeding owing to its narrow therapeutic window and unpredictable therapeutic dose. Pharmacogenetic-based dosing algorithms can improve accuracy of initial warfarin dosing but require rapid genotyping for cytochrome P-450 2C9 (CYP2C9) *2 and *3 single nucleotide polymorphisms (SNPs) and a vitamin K epoxide reductase (VKORC1) SNP. We evaluated 4 commercial systems: INFINITI analyzer (AutoGenomics, Carlsbad, CA), Invader assay (Third Wave Technologies, Madison, WI), Tag-It Mutation Detection assay (Luminex Molecular Diagnostics, formerly Tm Bioscience, Toronto, Canada), and Pyrosequencing (Biotage, Uppsala, Sweden). We genotyped 112 DNA samples and resolved any discrepancies with bidirectional sequencing. The INFINITI analyzer was 100% accurate for all SNPs and required 8 hours. Invader and Tag-It were 100% accurate for CYP2C9 SNPs, 99% accurate for VKORC1 -1639/3673 SNP, and required 3 hours and 8 hours, respectively. Pyrosequencing was 99% accurate for CYP2C9 *2, 100% accurate for CYP2C9 *3, and 100% accurate for VKORC1 and required 4 hours. Current commercial platforms provide accurate and rapid genotypes for pharmacogenetic dosing during initiation of warfarin therapy.

  6. Determination of total antioxidant capacity by oxygen radical absorbance capacity (ORAC) using fluorescein as the fluorescence probe: First Action 2012.23.

    PubMed

    Ou, Boxin; Chang, Tony; Huang, Dejian; Prior, Ronald L

    2013-01-01

    An improved method for the measurement of oxygen radical absorbance capacity (ORAC) was developed and validated using fluorescein (3',6'-dihydroxyspiro[isobenzofuran-1[3H], 9'[9H]-xanthen]-3-one) as a new fluorescence probe (ORAC(FL)). Randomly methylated beta-cyclodextrin (RMCD) was introduced as the water-solubility enhancer for lipophilic antioxidants. 7% RMCD (w/v) in 50% acetone-H2O mixture sufficiently solubilized vitamin E compounds and other lipophilic phenolic antioxidants in 75 mM phosphate buffer (pH 7.4). Results indicated that fluorescein shows excellent photostability under the plate reader conditions. This ORAC(FL) was validated through linearity, precision, accuracy, and ruggedness. The validation results demonstrated that the ORACFL assay is reliable and robust. The mean of intraday and interday CVs were <15%; for hydrophilic ORAC, LOD and LOQ are 5 and 6.25 microM, respectively; for lipophilic ORAC, LOD and LOQ are 6.25 and 12.5 microM, respectively. It is concluded that unlike other popular methods, the ORAC(FL) assay provides a direct measure of total antioxidant capacity against the peroxyl radicals.

  7. Proper expression of metabolizable energy in avian energetics

    USGS Publications Warehouse

    Miller, M.R.; Reinecke, K.J.

    1984-01-01

    We review metabolizable energy (ME) concepts and present evidence suggesting that the form of ME used for analyses of avian energetics can affect interpretation of results. Apparent ME (AME) is the most widely used measure of food energy available to birds. True ME (TME) differs from AME in recognizing fecal and urinary energy of nonfood origin as metabolized energy. Only AME values obtained from test birds fed at maintenance levels should be used for energy analyses. A practical assay for TME has shown that TME estimates are less sensitive than AME to variation in food intake. The TME assay may be particularly useful in studies of natural foods that are difficult to obtain in quantities large enough to supply test birds with maintenance requirements. Energy budgets calculated from existence metabolism should be expressed as kJ of AME and converted to food requirements with estimates of metabolizability given in kJ AME/g. Energy budgets calculated from multiples of basal metabolic rate (a component of maintenance energy), however, should be expressed as kJ of either TME or net energy depending on ambient temperature. Energy units should be stated explicitly to improve comparability and in some cases accuracy of energy analyses.

  8. Perceptual experience and posttest improvements in perceptual accuracy and consistency.

    PubMed

    Wagman, Jeffrey B; McBride, Dawn M; Trefzger, Amanda J

    2008-08-01

    Two experiments investigated the relationship between perceptual experience (during practice) and posttest improvements in perceptual accuracy and consistency. Experiment 1 investigated the potential relationship between how often knowledge of results (KR) is provided during a practice session and posttest improvements in perceptual accuracy. Experiment 2 investigated the potential relationship between how often practice (PR) is provided during a practice session and posttest improvements in perceptual consistency. The results of both experiments are consistent with previous findings that perceptual accuracy improves only when practice includes KR and that perceptual consistency improves regardless of whether practice includes KR. In addition, the results showed that although there is a relationship between how often KR is provided during a practice session and posttest improvements in perceptual accuracy, there is no relationship between how often PR is provided during a practice session and posttest improvements in consistency.

  9. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards

    EPA Pesticide Factsheets

    EPA's air monitoring regulations require the use of Protocol Gases to set air pollution monitors. This protocol balances the government's need for accuracy with the producers' need for flexibility, low cost, and minimum external oversight.

  10. Evaluation of six serological ELISA kits available in Italy as screening tests for equine infectious anaemia surveillance.

    PubMed

    Nardini, Roberto; Autorino, Gian Luca; Issel, Charles J; Cook, R Frank; Ricci, Ida; Frontoso, Raffaele; Rosone, Francesca; Scicluna, Maria Teresa

    2017-04-14

    ELISAs are known to have a higher diagnostic sensitivity than the agar gel immunodiffusion (AGID) when employed for serological diagnosis of equine infectious anaemia (EIA). For this purpose, an "in-house" and five commercial ELISAs available in Italy were assessed by the National Reference Centre for EIA for their analytic specificity (Sp); precocity, defined as capability of detecting first antibodies produced during a new infection; precision based on repeatability and reproducibility, estimated from the coefficient of variation (CV); accuracy, estimated from multiple K and relative Sp and sensitivity (Se). Two serum panels, positive for non-equine retroviruses and the most frequent equine viruses, were employed to measure analytic Sp. ELISA precocity was also compared to that of one "in-house" and three commercial AGID kits, employing a panel of sera, collected weekly from horses infected with modified EIA viruses. Precision and accuracy were defined using results of a panel containing positive and negative sera examined in an inter-laboratory trial with the participation of the ten Official Laboratories. Furthermore, a questionnaire was used to assess the appropriateness of each kit for routine use. Analytic Sp was 100%, while the 75th percentile of CVs for positive sera varied from 0.4% to 12.73% for repeatability and from 1.6% to 44.87% for reproducibility. Although CV of the negative serum was constantly high, its outcome was unaltered. Relative Se ranged from 98.2% to 100%, relative Sp was constantly 100% and multiple K ranged from 0.95 to 1. Precocity differed among the assays: three kits detected 4.8% and 42.9% positive samples on 21 days post infection (dpi), all assays detected positive samples on 28 dpi, between 47.6% and 95.2%. Precocity of ELISAs was superior to that of the AGIDs except for two assays. In view of the feedback obtained from the questionnaires, all kits were considered appropriate for routine use. All ELISAs having high Se and precocity are preferable as a screening test in EIA surveillance programmes to the AGID tests examined. These two tests can be incorporated in a serial diagnostic pathway to improve the efficacy of a surveillance plan.

  11. Plasma procalcitonin concentrations are increased in dogs with sepsis

    PubMed Central

    Goggs, Robert; Milloway, Matthew; Troia, Roberta; Giunti, Massimo

    2018-01-01

    Sepsis, the life-threatening organ dysfunction caused by a dysregulated host response to infection, is difficult to identify and to prognosticate for. In people with sepsis, procalcitonin (PCT) measurement aids diagnosis, enables therapeutic monitoring and improves prognostic accuracy. This study used a commercial canine PCT assay to measure plasma PCT concentrations in dogs with gastric dilatation volvulus (GDV) syndrome and in dogs with sepsis. It was hypothesised that dogs with GDV syndrome and with sepsis have greater plasma PCT concentrations than healthy dogs and that dogs with sepsis have greater PCT concentrations than dogs with GDV syndrome. Before analysing canine plasma samples, the ability of the assay to identify canine PCT, in addition to assay imprecision and the lower limit of detection were established. The assay had low imprecision with coefficients of variation ≤4.5 per cent. The lower limit of detection was 3.4 pg/ml. Plasma PCT concentrations were measured in 20 dogs with sepsis, in 32 dogs with GDV syndrome and in 52 healthy dogs. Median (IQR) PCT concentration in dogs with sepsis 78.7 pg/ml (39.1–164.7) was significantly greater than in healthy dogs 49.8 pg/ml (36.2–63.7) (P=0.019), but there were no significant differences between PCT concentrations in dogs with GDV syndrome and controls (P=0.072) or between dogs with sepsis and GDV syndrome (P=1.000). Dogs with sepsis have significantly increased plasma PCT concentrations compared with healthy dogs, although considerable overlap between these populations was identified. Future investigations should confirm this finding in other populations and evaluate the diagnostic and prognostic value of PCT in dogs with sepsis. PMID:29682292

  12. Improved Motor-Timing: Effects of Synchronized Metro-Nome Training on Golf Shot Accuracy

    PubMed Central

    Sommer, Marius; Rönnqvist, Louise

    2009-01-01

    This study investigates the effect of synchronized metronome training (SMT) on motor timing and how this training might affect golf shot accuracy. Twenty-six experienced male golfers participated (mean age 27 years; mean golf handicap 12.6) in this study. Pre- and post-test investigations of golf shots made by three different clubs were conducted by use of a golf simulator. The golfers were randomized into two groups: a SMT group and a Control group. After the pre-test, the golfers in the SMT group completed a 4-week SMT program designed to improve their motor timing, the golfers in the Control group were merely training their golf-swings during the same time period. No differences between the two groups were found from the pre-test outcomes, either for motor timing scores or for golf shot accuracy. However, the post-test results after the 4-weeks SMT showed evident motor timing improvements. Additionally, significant improvements for golf shot accuracy were found for the SMT group and with less variability in their performance. No such improvements were found for the golfers in the Control group. As with previous studies that used a SMT program, this study’s results provide further evidence that motor timing can be improved by SMT and that such timing improvement also improves golf accuracy. Key points This study investigates the effect of synchronized metronome training (SMT) on motor timing and how this training might affect golf shot accuracy. A randomized control group design was used. The 4 week SMT intervention showed significant improvements in motor timing, golf shot accuracy, and lead to less variability. We conclude that this study’s results provide further evidence that motor timing can be improved by SMT training and that such timing improvement also improves golf accuracy. PMID:24149608

  13. Absorbance and fluorometric sensing with capillary wells microplates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian

    2010-12-15

    Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly inmore » the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.« less

  14. Optimization and qualification of an Fc Array assay for assessments of antibodies against HIV-1/SIV.

    PubMed

    Brown, Eric P; Weiner, Joshua A; Lin, Shu; Natarajan, Harini; Normandin, Erica; Barouch, Dan H; Alter, Galit; Sarzotti-Kelsoe, Marcella; Ackerman, Margaret E

    2018-04-01

    The Fc Array is a multiplexed assay that assesses the Fc domain characteristics of antigen-specific antibodies with the potential to evaluate up to 500 antigen specificities simultaneously. Antigen-specific antibodies are captured on antigen-conjugated beads and their functional capacity is probed via an array of Fc-binding proteins including antibody subclassing reagents, Fcγ receptors, complement proteins, and lectins. Here we present the results of the optimization and formal qualification of the Fc Array, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. Assay conditions were optimized for performance and reproducibility, and the final version of the assay was then evaluated for specificity, accuracy, precision, limits of detection and quantitation, linearity, range and robustness. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Development of a test for bovine tuberculosis in cattle based on measurement of gamma interferon mRNA by real-time PCR.

    PubMed

    Gan, W; Zhou, X; Yang, H; Chen, H; Qiao, J; Khan, S H; Yang, L; Yin, X; Zhao, D

    2013-08-03

    The infection status of cattle for bovine tuberculosis (bTB) was determined by real-time PCR, comparing the levels of IFN-γ mRNA in blood cultures stimulated with either bovine or avian tuberculin with non-stimulated control (phosphate buffer saline, PBS) blood culture. Totally, 137 cattle were tested to validate the assay, in which 54 were IFN-γ real-time quantitative PCR (RT-qPCR) positive, while the remaining 83 were found negative. Meanwhile, the IFN-γ ELISA test was carried out using the Bovigam IFN-γ detection ELISA kit and these results were used as a standard. The results of the single intradermal tuberculin tests (SIDT) and IFN-γ RT-qPCR tests were compared and revealed that the RT-qPCR correlated better with the ELISA and its accuracy was higher than SIDT. This indicates the RT-qPCR is a useful diagnostic method for bTB in cattle. However, several limitations remain for our approach, such as lack of a TB lesions or postmortem test results as a gold standard. Further improvements should be made in the future to increase accuracy of diagnosis of bTB in cattle.

  16. Multiparametric plasma EV profiling facilitates diagnosis of pancreatic malignancy.

    PubMed

    Yang, Katherine S; Im, Hyungsoon; Hong, Seonki; Pergolini, Ilaria; Del Castillo, Andres Fernandez; Wang, Rui; Clardy, Susan; Huang, Chen-Han; Pille, Craig; Ferrone, Soldano; Yang, Robert; Castro, Cesar M; Lee, Hakho; Del Castillo, Carlos Fernandez; Weissleder, Ralph

    2017-05-24

    Pancreatic ductal adenocarcinoma (PDAC) is usually detected late in the disease process. Clinical workup through imaging and tissue biopsies is often complex and expensive due to a paucity of reliable biomarkers. We used an advanced multiplexed plasmonic assay to analyze circulating tumor-derived extracellular vesicles (tEVs) in more than 100 clinical populations. Using EV-based protein marker profiling, we identified a signature of five markers (PDAC EV signature) for PDAC detection. In our prospective cohort, the accuracy for the PDAC EV signature was 84% [95% confidence interval (CI), 69 to 93%] but only 63 to 72% for single-marker screening. One of the best markers, GPC1 alone, had a sensitivity of 82% (CI, 60 to 95%) and a specificity of 52% (CI, 30 to 74%), whereas the PDAC EV signature showed a sensitivity of 86% (CI, 65 to 97%) and a specificity of 81% (CI, 58 to 95%). The PDAC EV signature of tEVs offered higher sensitivity, specificity, and accuracy than the existing serum marker (CA 19-9) or single-tEV marker analyses. This approach should improve the diagnosis of pancreatic cancer. Copyright © 2017, American Association for the Advancement of Science.

  17. Potential transducers based man-tailored biomimetic sensors for selective recognition of dextromethorphan as an antitussive drug.

    PubMed

    El-Naby, Eman H; Kamel, Ayman H

    2015-09-01

    A biomimetic potentiometric sensor for specific recognition of dextromethorphan (DXM), a drug classified according to the Drug Enforcement Administration (DEA) as a "drug of concern", is designed and characterized. A molecularly imprinted polymer (MIP), with special molecular recognition properties of DXM, was prepared by thermal polymerization in which DXM acted as template molecule, methacrylic acid (MAA) and acrylonitrile (AN) acted as functional monomers in the presence of ethylene glycol dimethacrylate (EGDMA) as crosslinker. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors revealed near-Nernstian response with slopes of 49.6±0.5 and 53.4±0.5 mV decade(-1) with a detection limit of 1.9×10(-6), and 1.0×10(-6) mol L(-1) DXM with MIP/MAA and MIP/AN membrane based sensors, respectively. Significantly improved accuracy, precision, response time, stability, selectivity and sensitivity were offered by these simple and cost-effective potentiometric sensors compared with other standard techniques. The method has the requisite accuracy, sensitivity and precision to assay DXM in pharmaceutical products. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Time-dependent classification accuracy curve under marker-dependent sampling.

    PubMed

    Zhu, Zhaoyin; Wang, Xiaofei; Saha-Chaudhuri, Paramita; Kosinski, Andrzej S; George, Stephen L

    2016-07-01

    Evaluating the classification accuracy of a candidate biomarker signaling the onset of disease or disease status is essential for medical decision making. A good biomarker would accurately identify the patients who are likely to progress or die at a particular time in the future or who are in urgent need for active treatments. To assess the performance of a candidate biomarker, the receiver operating characteristic (ROC) curve and the area under the ROC curve (AUC) are commonly used. In many cases, the standard simple random sampling (SRS) design used for biomarker validation studies is costly and inefficient. In order to improve the efficiency and reduce the cost of biomarker validation, marker-dependent sampling (MDS) may be used. In a MDS design, the selection of patients to assess true survival time is dependent on the result of a biomarker assay. In this article, we introduce a nonparametric estimator for time-dependent AUC under a MDS design. The consistency and the asymptotic normality of the proposed estimator is established. Simulation shows the unbiasedness of the proposed estimator and a significant efficiency gain of the MDS design over the SRS design. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Automation of a Nile red staining assay enables high throughput quantification of microalgal lipid production.

    PubMed

    Morschett, Holger; Wiechert, Wolfgang; Oldiges, Marco

    2016-02-09

    Within the context of microalgal lipid production for biofuels and bulk chemical applications, specialized higher throughput devices for small scale parallelized cultivation are expected to boost the time efficiency of phototrophic bioprocess development. However, the increasing number of possible experiments is directly coupled to the demand for lipid quantification protocols that enable reliably measuring large sets of samples within short time and that can deal with the reduced sample volume typically generated at screening scale. To meet these demands, a dye based assay was established using a liquid handling robot to provide reproducible high throughput quantification of lipids with minimized hands-on-time. Lipid production was monitored using the fluorescent dye Nile red with dimethyl sulfoxide as solvent facilitating dye permeation. The staining kinetics of cells at different concentrations and physiological states were investigated to successfully down-scale the assay to 96 well microtiter plates. Gravimetric calibration against a well-established extractive protocol enabled absolute quantification of intracellular lipids improving precision from ±8 to ±2 % on average. Implementation into an automated liquid handling platform allows for measuring up to 48 samples within 6.5 h, reducing hands-on-time to a third compared to manual operation. Moreover, it was shown that automation enhances accuracy and precision compared to manual preparation. It was revealed that established protocols relying on optical density or cell number for biomass adjustion prior to staining may suffer from errors due to significant changes of the cells' optical and physiological properties during cultivation. Alternatively, the biovolume was used as a measure for biomass concentration so that errors from morphological changes can be excluded. The newly established assay proved to be applicable for absolute quantification of algal lipids avoiding limitations of currently established protocols, namely biomass adjustment and limited throughput. Automation was shown to improve data reliability, as well as experimental throughput simultaneously minimizing the needed hands-on-time to a third. Thereby, the presented protocol meets the demands for the analysis of samples generated by the upcoming generation of devices for higher throughput phototrophic cultivation and thereby contributes to boosting the time efficiency for setting up algae lipid production processes.

  20. Application of miniaturized near-infrared spectroscopy for quality control of extemporaneous orodispersible films.

    PubMed

    Foo, Wen Chin; Widjaja, Effendi; Khong, Yuet Mei; Gokhale, Rajeev; Chan, Sui Yung

    2018-02-20

    Extemporaneous oral preparations are routinely compounded in the pharmacy due to a lack of suitable formulations for special populations. Such small-scale pharmacy preparations also present an avenue for individualized pharmacotherapy. Orodispersible films (ODF) have increasingly been evaluated as a suitable dosage form for extemporaneous oral preparations. Nevertheless, as with all other extemporaneous preparations, safety and quality remain a concern. Although the United States Pharmacopeia (USP) recommends analytical testing of compounded preparations for quality assurance, pharmaceutical assays are typically not routinely performed for such non-sterile pharmacy preparations, due to the complexity and high cost of conventional assay methods such as high performance liquid chromatography (HPLC). Spectroscopic methods including Raman, infrared and near-infrared spectroscopy have been successfully applied as quality control tools in the industry. The state-of-art benchtop spectrometers used in those studies have the advantage of superior resolution and performance, but are not suitable for use in a small-scale pharmacy setting. In this study, we investigated the application of a miniaturized near infrared (NIR) spectrometer as a quality control tool for identification and quantification of drug content in extemporaneous ODFs. Miniaturized near infrared (NIR) spectroscopy is suitable for small-scale pharmacy applications in view of its small size, portability, simple user interface, rapid measurement and real-time prediction results. Nevertheless, the challenge with miniaturized NIR spectroscopy is its lower resolution compared to state-of-art benchtop equipment. We have successfully developed NIR spectroscopy calibration models for identification of ODFs containing five different drugs, and quantification of drug content in ODFs containing 2-10mg ondansetron (OND). The qualitative model for drug identification produced 100% prediction accuracy. The quantitative model to predict OND drug content in ODFs was divided into two calibrations for improved accuracy: Calibration I and II covered the 2-4mg and 4-10mg ranges respectively. Validation was performed for method accuracy, linearity and precision. In conclusion, this study demonstrates the feasibility of miniaturized NIR spectroscopy as a quality control tool for small-scale, pharmacy preparations. Due to its non-destructive nature, every dosage unit can be tested thus affording positive impact on patient safety. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The Lumipulse G HBsAg-Quant assay for screening and quantification of the hepatitis B surface antigen.

    PubMed

    Yang, Ruifeng; Song, Guangjun; Guan, Wenli; Wang, Qian; Liu, Yan; Wei, Lai

    2016-02-01

    Qualitative HBsAg assay is used to screen HBV infection for decades. The utility of quantitative assay is also rejuvenated recently. We aimed to evaluate and compare the performance of a novel ultra-sensitive and quantitative assay, the Lumipulse assay, with the Architect and Elecsys assays. As screening methods, specificity was compared using 2043 consecutive clinical routine samples. As quantitative assays, precision and accuracy were assessed. Sera from 112 treatment-naïve chronic hepatitis B patients, four patients undergoing antiviral therapy and one patient with acute infection were tested to compare the correlations. Samples with concurrent HBsAg/anti-HBs were also quantified. The Lumipulse assay precisely quantified ultra-low level of HBsAg (0.004 IU/mL). It identified additional 0.98% (20/2043) clinical samples with trance amount of HBsAg. Three assays displayed excellent linear correlations irrespective of genotypes and S-gene mutations (R(2)>0.95, P<0.0001), while minor quantitative biases existed. The Lumipulse assay did not yield higher HBsAg concentrations in samples with concomitant anti-HBs. Compared with other assays, the Lumipulse assay is sensitive and specific for detecting HBsAg. The interpretation of the extremely low-level results, however, is challenging. Quantitative HBsAg results by different assays are highly correlated, but they should be interpreted interchangeably only after conversion to eliminate the biases. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Smartphone-based colorimetric ELISA implementation for determination of women's reproductive steroid hormone profiles.

    PubMed

    Ogirala, Tejaswi; Eapen, Ashley; Salvante, Katrina G; Rapaport, Tomas; Nepomnaschy, Pablo A; Parameswaran, Ash M

    2017-10-01

    Biologists frequently collect and analyze biospecimens in naturalistic (i.e., field) conditions to ascertain information regarding the physiological status of their study participants. Generally, field-collected biospecimens need to be stored frozen in the field and then transported frozen to laboratory facilities where traditional biomarker assays, such as enzyme-linked immunosorbent assays (ELISAs), are conducted. As proper storage and transport of frozen specimens is often logistically difficult and expensive, particularly in nonurban field settings, methods that reduce the need for specimen storage and transport would benefit field-research dependent disciplines such as biology, ecology and epidemiology. One limiting factor to running assays in the field is the use of large and expensive equipment to visualize and quantify the assays, such as microplate readers. Here, we describe an implementation of colorimetric ELISA visualization and quantification using two novel and portable imaging instrumentation systems and data processing techniques for the determination of women's reproductive steroid hormone profiles. Using the light absorbance and transmittance properties of the chemical compounds that make up the hormone assay, we were able to estimate unknown hormone concentrations using a smartphone system and a webcam system. These estimates were comparable to those from a standard laboratory multiple reader (smartphone: accuracy = 82.20%, R 2  > 0.910; webcam: accuracy = 87.59%, R 2  > 0.942). This line of applied research, in the long run, is expected to provide necessary information for examining the extent to which reproductive function varies within and between populations and how it is influenced by psychosocial, energetic and environmental challenges. Our validation of these novel, portable visualization and quantification systems allows for the eventual development of a compact and economical closed system which can be used to quantify biomarker concentrations in remote areas.

  3. Evaluation of the MeltPro TB/STR assay for rapid detection of streptomycin resistance in Mycobacterium tuberculosis.

    PubMed

    Zhang, Ting; Hu, Siyu; Li, Guoli; Li, Hui; Liu, Xiaoli; Niu, Jianjun; Wang, Feng; Wen, Huixin; Xu, Ye; Li, Qingge

    2015-03-01

    Rapid and comprehensive detection of drug-resistance is essential for the control of tuberculosis, which has facilitated the development of molecular assays for the detection of drug-resistant mutations in Mycobacterium tuberculosis. We hereby assessed the analytical and clinical performance of an assay for streptomycin-resistant mutations. MeltPro TB/STR is a closed-tube, dual-color, melting curve analysis-based, real-time PCR test designed to detect 15 streptomycin-resistant mutations in rpsL 43, rpsL 88, rrs 513, rrs 514, rrs 517, and rrs 905-908 of M. tuberculosis. Analytical studies showed that the accuracy was 100%, the limit of detection was 50-500 bacilli per reaction, the reproducibility in the form of Tm variation was within 1.0 °C, and we could detect 20% STR resistance in mixed bacterial samples. The cross-platform study demonstrated that the assay could be performed on six models of real-time PCR instruments. A multicenter clinical study was conducted using 1056 clinical isolates, which were collected from three geographically different healthcare units, including 709 STR-susceptible and 347 STR-resistant isolates characterized on Löwenstein-Jensen solid medium by traditional drug susceptibility testing. The results showed that the clinical sensitivity and specificity of the MeltPro TB/STR was 88.8% and 95.8%, respectively. Sequencing analysis confirmed the accuracy of the mutation types. Among all the 8 mutation types detected, rpsL K43R (AAG → AGG), rpsL K88R (AAG → AGG) and rrs 514 A → C accounted for more than 90%. We concluded that MeltPro TB/STR represents a rapid and reliable assay for the detection of STR resistance in clinical isolates. Copyright © 2014. Published by Elsevier Ltd.

  4. Cross-Disciplinary Biomarkers Research: Lessons Learned by the CKD Biomarkers Consortium.

    PubMed

    Hsu, Chi-Yuan; Ballard, Shawn; Batlle, Daniel; Bonventre, Joseph V; Böttinger, Erwin P; Feldman, Harold I; Klein, Jon B; Coresh, Josef; Eckfeldt, John H; Inker, Lesley A; Kimmel, Paul L; Kusek, John W; Liu, Kathleen D; Mauer, Michael; Mifflin, Theodore E; Molitch, Mark E; Nelsestuen, Gary L; Rebholz, Casey M; Rovin, Brad H; Sabbisetti, Venkata S; Van Eyk, Jennifer E; Vasan, Ramachandran S; Waikar, Sushrut S; Whitehead, Krista M; Nelson, Robert G

    2015-05-07

    Significant advances are needed to improve the diagnosis, prognosis, and management of persons with CKD. Discovery of new biomarkers and improvements in currently available biomarkers for CKD hold great promise to achieve these necessary advances. Interest in identification and evaluation of biomarkers for CKD has increased substantially over the past decade. In 2009, the National Institute of Diabetes and Digestive and Kidney Diseases established the CKD Biomarkers Consortium (http://www.ckdbiomarkersconsortium.org/), a multidisciplinary, collaborative study group located at over a dozen academic medical centers. The main objective of the consortium was to evaluate new biomarkers for purposes related to CKD in established prospective cohorts, including those enriched for CKD. During the first 5 years of the consortium, many insights into collaborative biomarker research were gained that may be useful to other investigators involved in biomarkers research. These lessons learned are outlined in this Special Feature and include a wide range of issues related to biospecimen collection, storage, and retrieval, and the internal and external quality assessment of laboratories that performed the assays. The authors propose that investigations involving biomarker discovery and validation are greatly enhanced by establishing and following explicit quality control metrics, including the use of blind replicate and proficiency samples, by carefully considering the conditions under which specimens are collected, handled, and stored, and by conducting pilot and feasibility studies when there are concerns about the condition of the specimens or the accuracy or reproducibility of the assays. Copyright © 2015 by the American Society of Nephrology.

  5. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    PubMed

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  6. Bench-top validation testing of selected immunological and molecular Renibacterium salmoninarum diagnostic assays by comparison with quantitative bacteriological culture

    USGS Publications Warehouse

    Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.

    2013-01-01

    No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.

  7. Accuracy of a rapid real-time polymerase chain reaction assay for diagnosis of group B Streptococcus colonization in a cohort of HIV-infected pregnant women.

    PubMed

    Gouvea, Maria Isabel S; Joao, Esau C; Teixeira, Maria de Lourdes B; Read, Jennifer S; Fracalanzza, Sergio E L; Souza, Claudia T V; Souza, Maria José de; Torres Filho, Helio M; Leite, Cassiana C F; do Brasil, Pedro E A A

    2017-05-01

    There are limited data regarding Xpert performance to detect Group B Streptococcus (GBS) in HIV-infected pregnant women. We evaluated the accuracy of a rapid real-time polymerase chain reaction (PCR) test in a cohort of HIV-infected women. At 35-37 weeks of pregnancy, a pair of combined rectovaginal swabs were collected for two GBS assays in a cohort of sequentially included HIV-infected women in Rio de Janeiro: (1) culture; and (2) real-time PCR assay [GeneXpert GBS (Cepheid, Sunnyvale, CA)]. Using culture as the reference, sensitivity, specificity, positive and negative-likelihood ratios were estimated. From June 2012 to February 2015, 337 pregnant women met inclusion criteria. One woman was later excluded, due to failure to obtain a result in the index test; 336 were included in the analyses. The GBS colonization rate was 19.04%. Sensitivity and specificity of the GeneXpert GBS assay were 85.94% (95% CI: 75.38-92.42) and 94.85% (95% CI: 91.55-96.91), respectively. Positive and negative predictive values were 79.71% (95% CI: 68.78-87.51) and 96.63% (95% CI: 93.72-98.22), respectively. GeneXpert GBS is an acceptable test for the identification of GBS colonization in HIV-infected pregnant women and represents a reasonable option to detect GBS colonization in settings where culture is not feasible.

  8. Allergen-specific IgE measurement with the IMMULITE 2000 system: intermethod comparison of detection performance for allergen-specific IgE antibodies from Korean allergic patients.

    PubMed

    Lee, Yong Won; Sohn, Jung Ho; Lee, Jae-Hyun; Hong, Chein-Soo; Park, Jung-Won

    2009-03-01

    Intermethod comparison between IMMULITE 2000 chemiluminescent enzyme immunoassay (CLEIA) and the established CAP test for allergen-specific IgE (sIgE) has only been evaluated by a few studies. We performed such an interassay comparison using 283 Korean allergic patients with the following: asthma (18.4%), allergic rhinitis (18.4%), both asthma and allergic rhinitis (14.5%), atopic dermatitis (21.9%), and others (26.8%). We compared the sIgE detection performance of both systems for 10 major inhalant allergens (Dermatophagoides pteronyssinus, Dermatophagoides farinae, Blattela germanica, cat dander, dog hair, alder, birch, oak, ragweed, and mugwort) and four food allergens (egg white, cow milk, peanut, and shrimp). After 645 paired comparison tests, close association and significant correlation were observed between the results of both assays for most of these allergens (r=0.525-0.979, p<0.05, respectively), except for shrimp. Intermethod agreement based on sIgE detection was fair to good (74.1-100%, kappa=0.514-1.000, p<0.05, respectively) for most allergens except for B. germanica, ragweed, and shrimp. Although both assays showed good accuracy in ROC curve analysis, some minor differences were noted. IMMULITE 2000 CLEIA for sIgE detection showed fair to good intermethod correlation, association, agreement, and accuracy in comparison to the established CAP assay among Korean allergic patients. However, we should take into account the intermethod differences between both assays for clinical applications.

  9. Multiplexed MRM-based quantitation of candidate cancer biomarker proteins in undepleted and non-enriched human plasma.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Borchers, Christoph H

    2013-07-01

    An emerging approach for multiplexed targeted proteomics involves bottom-up LC-MRM-MS, with stable isotope-labeled internal standard peptides, to accurately quantitate panels of putative disease biomarkers in biofluids. In this paper, we used this approach to quantitate 27 candidate cancer-biomarker proteins in human plasma that had not been treated by immunoaffinity depletion or enrichment techniques. These proteins have been reported as biomarkers for a variety of human cancers, from laryngeal to ovarian, with breast cancer having the highest correlation. We implemented measures to minimize the analytical variability, improve the quantitative accuracy, and increase the feasibility and applicability of this MRM-based method. We have demonstrated excellent retention time reproducibility (median interday CV: 0.08%) and signal stability (median interday CV: 4.5% for the analytical platform and 6.1% for the bottom-up workflow) for the 27 biomarker proteins (represented by 57 interference-free peptides). The linear dynamic range for the MRM assays spanned four orders-of-magnitude, with 25 assays covering a 10(3) -10(4) range in protein concentration. The lowest abundance quantifiable protein in our biomarker panel was insulin-like growth factor 1 (calculated concentration: 127 ng/mL). Overall, the analytical performance of this assay demonstrates high robustness and sensitivity, and provides the necessary throughput and multiplexing capabilities required to verify and validate cancer-associated protein biomarker panels in human plasma, prior to clinical use. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Filling the concept with data: integrating data from different in vitro and in silico assays on skin sensitizers to explore the battery approach for animal-free skin sensitization testing.

    PubMed

    Natsch, Andreas; Emter, Roger; Ellis, Graham

    2009-01-01

    Tests for skin sensitization are required prior to the market launch of new cosmetic ingredients. Significant efforts are made to replace the current animal tests. It is widely recognized that this cannot be accomplished with a single in vitro test, but that rather the integration of results from different in vitro and in silico assays will be needed for the prediction of the skin sensitization potential of chemicals. This has been proposed as a theoretical scheme so far, but no attempts have been made to use experimental data to prove the validity of this concept. Here we thus try for the first time to fill this widely cited concept with data. To this aim, we integrate and report both novel and literature data on 116 chemicals of known skin sensitization potential on the following parameters: (1) peptide reactivity as a surrogate for protein binding, (2) induction of antioxidant/electrophile responsive element dependent luciferase activity as a cell-based assay; (3) Tissue Metabolism Simulator skin sensitization model in silico prediction; and (4) calculated octanol-water partition coefficient. The results of the in vitro assays were scaled into five classes from 0 to 4 to give an in vitro score and compared to the local lymph node assay (LLNA) data, which were also scaled from 0 to 4 (nonsensitizer/weak/moderate/strong/extreme). Different ways of evaluating these data have been assessed to rate the hazard of chemicals (Cooper statistics) and to also scale their potency. With the optimized model an overall accuracy for predicting sensitizers of 87.9% was obtained. There is a linear correlation between the LLNA score and the in vitro score. However, the correlation needs further improvement as there is still a relatively high variation in the in vitro score between chemicals belonging to the same sensitization potency class.

  11. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799

  12. A multiplex immunochromatographic test using gold nanoparticles for the rapid and simultaneous detection of four nitrofuran metabolites in fish samples.

    PubMed

    Wang, Quan; Liu, Yingchun; Wang, Mingyan; Chen, Yongjun; Jiang, Wei

    2018-01-01

    There is an urgent need for the rapid and simultaneous detection of multiple analytes present in a sample matrix. Here, a multiplex immunochromatographic test (multi-ICT) was developed that successfully allowed for the rapid and simultaneous detection of four major nitrofuran metabolites, i.e., 3-amino-2-oxazolidinone (AOZ), semicarbazide (SEM), 3-amino-5-methylmorpholino-2-oxazolidinone (AMOZ), and 1-aminohydantoin (AHD), in fish samples. Four different antigens were separately immobilized in four test lines on a nitrocellulose membrane. Goat anti-mouse immunoglobulin (IgG) was used as a control. Sensitive and specific monoclonal antibodies (mAbs) that recognize the corresponding antigens were selected for the assay, and no cross-reactivity between the antibodies in the detection assay was observed. The free analytes in samples or standards were pre-incubated with freeze-dried mAb-gold conjugates to improve the sensitivity of the detection assay. The multi-ICT detection was accomplished in less than 15 min by the naked eye. The cutoff values for the strip test were 0.5 ng/mL for AOZ and 0.75 ng/mL for AHD, SEM, and AMOZ, which were all below the maximum residue levels set by the European Union and China. A high degree of consistency was observed between the multi-ICT method and commercially available enzyme-linked immunosorbent assay (ELISA) kits using spiked, incurred, and "blind" fish samples, indicating the accuracy, reproducibility, and reliability of the novel test strip. This newly developed multi-ICT strip assay is suitable for the rapid and high-throughput screening of four nitrofuran metabolites in fish samples on-site, with no treatment or devices required. Graphical abstract A multiplex immunochromatographic test (multi-ICT) was developed that successfully allowed for the rapid and simultaneous detection of four major nitrofuran metabolites (AOZ, SEM, AMOZ, and AHD) in fish samples.

  13. Evaluating the accuracy of SHAPE-directed RNA secondary structure predictions

    PubMed Central

    Sükösd, Zsuzsanna; Swenson, M. Shel; Kjems, Jørgen; Heitsch, Christine E.

    2013-01-01

    Recent advances in RNA structure determination include using data from high-throughput probing experiments to improve thermodynamic prediction accuracy. We evaluate the extent and nature of improvements in data-directed predictions for a diverse set of 16S/18S ribosomal sequences using a stochastic model of experimental SHAPE data. The average accuracy for 1000 data-directed predictions always improves over the original minimum free energy (MFE) structure. However, the amount of improvement varies with the sequence, exhibiting a correlation with MFE accuracy. Further analysis of this correlation shows that accurate MFE base pairs are typically preserved in a data-directed prediction, whereas inaccurate ones are not. Thus, the positive predictive value of common base pairs is consistently higher than the directed prediction accuracy. Finally, we confirm sequence dependencies in the directability of thermodynamic predictions and investigate the potential for greater accuracy improvements in the worst performing test sequence. PMID:23325843

  14. Optimized p53 immunohistochemistry is an accurate predictor of TP53 mutation in ovarian carcinoma.

    PubMed

    Köbel, Martin; Piskorz, Anna M; Lee, Sandra; Lui, Shuhong; LePage, Cecile; Marass, Francesco; Rosenfeld, Nitzan; Mes Masson, Anne-Marie; Brenton, James D

    2016-10-01

    TP53 mutations are ubiquitous in high-grade serous ovarian carcinomas (HGSOC), and the presence of TP53 mutation discriminates between high and low-grade serous carcinomas and is now an important biomarker for clinical trials targeting mutant p53. p53 immunohistochemistry (IHC) is widely used as a surrogate for TP53 mutation but its accuracy has not been established. The objective of this study was to test whether improved methods for p53 IHC could reliably predict TP53 mutations independently identified by next generation sequencing (NGS). Four clinical p53 IHC assays and tagged-amplicon NGS for TP53 were performed on 171 HGSOC and 80 endometrioid carcinomas (EC). p53 expression was scored as overexpression (OE), complete absence (CA), cytoplasmic (CY) or wild type (WT). p53 IHC was evaluated as a binary classifier where any abnormal staining predicted deleterious TP53 mutation and as a ternary classifier where OE, CA or WT staining predicted gain-of-function (GOF or nonsynonymous), loss-of-function (LOF including stopgain, indel, splicing) or no detectable TP53 mutations (NDM), respectively. Deleterious TP53 mutations were detected in 169/171 (99%) HGSOC and 7/80 (8.8%) EC. The overall accuracy for the best performing IHC assay for binary and ternary prediction was 0.94 and 0.91 respectively, which improved to 0.97 (sensitivity 0.96, specificity 1.00) and 0.95 after secondary analysis of discordant cases. The sensitivity for predicting LOF mutations was lower at 0.76 because p53 IHC detected mutant p53 protein in 13 HGSOC with LOF mutations. CY staining associated with LOF was seen in 4 (2.3%) of HGSOC. Optimized p53 IHC can approach 100% specificity for the presence of TP53 mutation and its high negative predictive value is clinically useful as it can exclude the possibility of a low-grade serous tumour. 4.1% of HGSOC cases have detectable WT staining while harboring a TP53 LOF mutation, which limits sensitivity for binary prediction of mutation to 96%.

  15. Optimized p53 immunohistochemistry is an accurate predictor of TP53 mutation in ovarian carcinoma

    PubMed Central

    Köbel, Martin; Piskorz, Anna M; Lee, Sandra; Lui, Shuhong; LePage, Cecile; Marass, Francesco; Rosenfeld, Nitzan; Mes Masson, Anne‐Marie

    2016-01-01

    Abstract TP53 mutations are ubiquitous in high‐grade serous ovarian carcinomas (HGSOC), and the presence of TP53 mutation discriminates between high and low‐grade serous carcinomas and is now an important biomarker for clinical trials targeting mutant p53. p53 immunohistochemistry (IHC) is widely used as a surrogate for TP53 mutation but its accuracy has not been established. The objective of this study was to test whether improved methods for p53 IHC could reliably predict TP53 mutations independently identified by next generation sequencing (NGS). Four clinical p53 IHC assays and tagged‐amplicon NGS for TP53 were performed on 171 HGSOC and 80 endometrioid carcinomas (EC). p53 expression was scored as overexpression (OE), complete absence (CA), cytoplasmic (CY) or wild type (WT). p53 IHC was evaluated as a binary classifier where any abnormal staining predicted deleterious TP53 mutation and as a ternary classifier where OE, CA or WT staining predicted gain‐of‐function (GOF or nonsynonymous), loss‐of‐function (LOF including stopgain, indel, splicing) or no detectable TP53 mutations (NDM), respectively. Deleterious TP53 mutations were detected in 169/171 (99%) HGSOC and 7/80 (8.8%) EC. The overall accuracy for the best performing IHC assay for binary and ternary prediction was 0.94 and 0.91 respectively, which improved to 0.97 (sensitivity 0.96, specificity 1.00) and 0.95 after secondary analysis of discordant cases. The sensitivity for predicting LOF mutations was lower at 0.76 because p53 IHC detected mutant p53 protein in 13 HGSOC with LOF mutations. CY staining associated with LOF was seen in 4 (2.3%) of HGSOC. Optimized p53 IHC can approach 100% specificity for the presence of TP53 mutation and its high negative predictive value is clinically useful as it can exclude the possibility of a low‐grade serous tumour. 4.1% of HGSOC cases have detectable WT staining while harboring a TP53 LOF mutation, which limits sensitivity for binary prediction of mutation to 96%. PMID:27840695

  16. A novel microfluidic microplate as the next generation assay platform for enzyme linked immunoassays (ELISA).

    PubMed

    Kai, Junhai; Puntambekar, Aniruddha; Santiago, Nelson; Lee, Se Hwan; Sehy, David W; Moore, Victor; Han, Jungyoup; Ahn, Chong H

    2012-11-07

    In this work we introduce a novel microfluidic enzyme linked immunoassays (ELISA) microplate as the next generation assay platform for unparalleled assay performances. A combination of microfluidic technology with standard SBS-configured 96-well microplate architecture, in the form of microfluidic microplate technology, allows for the improvement of ELISA workflows, conservation of samples and reagents, improved reaction kinetics, and the ability to improve the sensitivity of the assay by multiple analyte loading. This paper presents the design and characterization of the microfluidic microplate, and its application in ELISA.

  17. High-performance liquid chromatography-tandem mass spectrometry as a reference for analysis of tacrolimus to assess two immunoassays in patients with liver and renal transplants.

    PubMed

    Salm, P; Taylor, P J; Clark, A; Balderson, G A; Grygotis, A; Norris, R L; Lynch, S V; Shaw, L M; Pond, S M

    1997-12-01

    The accuracy and imprecision of three assays used for therapeutic monitoring of tacrolimus were tested using blood-containing weighed-in amounts of the drug, an enzyme-linked immunosorbent assay (ELISA), a microparticle enzyme immunoassay (MEIA I), and a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS2) assay. Accuracy was acceptable for the HPLC-MS2 assay at all concentrations tested (< 10% deviation) and for the ELISA at 1.0 and 4.0 microg/l. Accuracy was not acceptable for the ELISA at 15.0 and 50.0 microg/l or for the MEIA I at all concentrations tested. Imprecision was acceptable for the HPLC-MS2 assay at all concentrations tested (coefficient of variation < 10%), for the ELISA at 15.0 and 50.0 microg/l, and for the MEIA I at 15.0 and 50.0 microg/l. Imprecision was not acceptable for the ELISA at 1.0 and 4.0 microg/l or for the MEIA I at 1.0 and 4.0 microg/l. This assessment with weighed-in amounts of tacrolimus verified the HPLC-MS2 assay as a reference method. The performance of the two immunoassays with HPLC-MS2 was then compared in the clinical setting using blood from patients with liver (n = 30) and renal (n = 37) transplants. In the liver transplant group (127 samples), the range of tacrolimus concentrations measured by HPLC-MS2, ELISA, and MEIA I was 1.9 to 31.8, 2.1 to 35.0, and less than 0.1 to 36.5 mg/l, respectively. In the renal transplant group (129 samples), the ranges were 1.7 to 26.1, 1.9 to 24.4, and 0.9 to 28.5 microg/l, respectively. Compared with the HPLC-MS2, the ELISA had minimal bias (0.1 to 0.2 microg/l) but unacceptable variability in values (SD > 13%). The MEIA I had unacceptable bias (1.7-1.8 microg/l) and variability (SD > 23%). These data indicated that neither the ELISA nor MEIA I is interchangeable with HPLC-MS2. Moreover, in view of the current trend to reduce the therapeutic dose of tacrolimus, quantitative results using the MEIA I would not be obtainable during therapeutic drug monitoring in some patients in whom effective therapeutic concentrations can be less than 5.0 microg/l.

  18. Discrete and Continuum Approximations for Collective Cell Migration in a Scratch Assay with Cell Size Dynamics.

    PubMed

    Matsiaka, Oleksii M; Penington, Catherine J; Baker, Ruth E; Simpson, Matthew J

    2018-04-01

    Scratch assays are routinely used to study the collective spreading of cell populations. In general, the rate at which a population of cells spreads is driven by the combined effects of cell migration and proliferation. To examine the effects of cell migration separately from the effects of cell proliferation, scratch assays are often performed after treating the cells with a drug that inhibits proliferation. Mitomycin-C is a drug that is commonly used to suppress cell proliferation in this context. However, in addition to suppressing cell proliferation, mitomycin-C also causes cells to change size during the experiment, as each cell in the population approximately doubles in size as a result of treatment. Therefore, to describe a scratch assay that incorporates the effects of cell-to-cell crowding, cell-to-cell adhesion, and dynamic changes in cell size, we present a new stochastic model that incorporates these mechanisms. Our agent-based stochastic model takes the form of a system of Langevin equations that is the system of stochastic differential equations governing the evolution of the population of agents. We incorporate a time-dependent interaction force that is used to mimic the dynamic increase in size of the agents. To provide a mathematical description of the average behaviour of the stochastic model we present continuum limit descriptions using both a standard mean-field approximation and a more sophisticated moment dynamics approximation that accounts for the density of agents and density of pairs of agents in the stochastic model. Comparing the accuracy of the two continuum descriptions for a typical scratch assay geometry shows that the incorporation of agent growth in the system is associated with a decrease in accuracy of the standard mean-field description. In contrast, the moment dynamics description provides a more accurate prediction of the evolution of the scratch assay when the increase in size of individual agents is included in the model.

  19. A Survey of Validation Strategies for CRISPR-Cas9 Editing.

    PubMed

    Sentmanat, Monica F; Peters, Samuel T; Florian, Colin P; Connelly, Jon P; Pruett-Miller, Shondra M

    2018-01-17

    The T7 endonuclease 1 (T7E1) mismatch detection assay is a widely used method for evaluating the activity of site-specific nucleases, such as the clustered regularly interspaced short palindromic repeats (CRISPR)-Cas9 system. To determine the accuracy and sensitivity of this assay, we compared the editing estimates derived by the T7E1 assay with that of targeted next-generation sequencing (NGS) in pools of edited mammalian cells. Here, we report that estimates of nuclease activity determined by T7E1 most often do not accurately reflect the activity observed in edited cells. Editing efficiencies of CRISPR-Cas9 complexes with similar activity by T7E1 can prove dramatically different by NGS. Additionally, we compared editing efficiencies predicted by the Tracking of Indels by Decomposition (TIDE) assay and the Indel Detection by Amplicon Analysis (IDAA) assay to that observed by targeted NGS for both cellular pools and single-cell derived clones. We show that targeted NGS, TIDE, and IDAA assays predict similar editing efficiencies for pools of cells but that TIDE and IDAA can miscall alleles in edited clones.

  20. Impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott RealTime HCV Genotype II assay for hepatitis C genotyping.

    PubMed

    Sridhar, Siddharth; Yip, Cyril C Y; Chan, Jasper F W; To, Kelvin K W; Cheng, Vincent C C; Yuen, Kwok-Yung

    2018-05-01

    The Abbott RealTime HCV Genotype II assay (Abbott-RT-HCV assay) is a real-time PCR based genotyping method for hepatitis C virus (HCV). This study measured the impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott-RT-HCV assay. 517 samples were genotyped using the Abbott-RT-HCV assay over a one-year period, 34 (6.6%) were identified as HCV genotype 1 without further subtype designation raising the possibility of inaccurate genotyping. These samples were subjected to confirmatory sequencing. 27 of these 34 (79%) samples were genotype 1b while five (15%) were genotype 6. One HCV isolate was an inter-genotypic 1a/4o recombinant. This is a novel natural HCV recombinant that has never been reported. Inter-genotypic recombination and probe cross-reactivity can affect the accuracy of the Abbott-RT-HCV assay, both of which have significant implications on antiviral regimen choice. Confirmatory sequencing of ambiguous results is crucial for accurate genotyping. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Allergen extracts and recombinant proteins: comparison of efficiency of in vitro allergy diagnostics using multiplex assay on a biological microchip.

    PubMed

    Smoldovskaya, Olga; Feyzkhanova, Guzel; Arefieva, Alla; Voloshin, Sergei; Ivashkina, Olga; Reznikov, Yuriy; Rubina, Alla

    2016-01-01

    Immunological test systems for diagnostics of type I hypersensitivity involve the following types of antigens: whole allergen extracts, individual highly purified proteins and their recombinant analogues. The goal of this study was to compare the results obtained with whole allergen extracts (birch pollen, cat dander, and timothy grass pollen) and their respective recombinant proteins in biochip-based immunoassay. Multiplex fluorescent immunoassay of 139 patients' blood serum samples was carried out using biological microchips (biochips). sIgE concentrations for the chosen allergens and their recombinant components were measured. ROC analysis was used for comparison of the results and determination of diagnostic accuracy. The results for the birch pollen extract and its recombinant allergens have shown that the diagnostic accuracy of the methods utilizing the whole allergen extract, its major component Bet v 1 and the combination of major and minor components (Bet v 1 and Bet v 2) was the same. Values for diagnostic accuracy for the cat dander extract and its major recombinant component Fel d 1 were equal. In contrast with birch pollen and cat dander allergens, using of recombinant components of timothy grass pollen (Phl p 1, Phl p 5, Phl p 7 and Phl p 12) did not allow reaching the diagnostic accuracy of using natural extract. Multiplex analysis of samples obtained from patients with allergy to birch pollen and cat dander using biological microchips has shown that comparable accuracy was observed for the assay with natural extracts and recombinant allergens. In the case of timothy grass allergen, using the recombinant components may be insufficient.

  2. A highly reproducible quantitative viral outgrowth assay for the measurement of the replication-competent latent HIV-1 reservoir.

    PubMed

    Fun, Axel; Mok, Hoi Ping; Wills, Mark R; Lever, Andrew M

    2017-02-24

    Cure of Human Immunodeficiency Virus (HIV) infection remains elusive due to the persistence of HIV in a latent reservoir. Strategies to eradicate latent infection can only be evaluated with robust, sensitive and specific assays to quantitate reactivatable latent virus. We have taken the standard peripheral blood mononuclear cell (PBMC) based viral outgrowth methodology and from it created a logistically simpler and more highly reproducible assay to quantify replication-competent latent HIV in resting CD4 + T cells, both increasing accuracy and decreasing cost and labour. Purification of resting CD4 + T cells from whole PBMC is expedited and achieved in 3 hours, less than half the time of conventional protocols. Our indicator cell line, SupT1-CCR5 cells (a clonal cell line expressing CD4, CXCR4 and CCR5) provides a readily available standardised readout. Reproducibility compares favourably to other published assays but with reduced cost, labour and assay heterogeneity without compromising sensitivity.

  3. High-Throughput Method for Automated Colony and Cell Counting by Digital Image Analysis Based on Edge Detection

    PubMed Central

    Choudhry, Priya

    2016-01-01

    Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies from digital images. For this purpose, I developed an ImageJ macro Cell Colony Edge and a CellProfiler Pipeline Cell Colony Counting, and compared them to other open-source digital methods and manual counts. The ImageJ macro Cell Colony Edge is valuable in counting cells and colonies, and measuring their area, volume, morphology, and intensity. In this study, I demonstrate that Cell Colony Edge is superior to other open-source methods, in speed, accuracy and applicability to diverse cellular assays. It can fulfill the need to automate colony/cell counting in high-throughput screens, colony forming assays, and cellular assays. PMID:26848849

  4. A systematic review of the PTSD Checklist's diagnostic accuracy studies using QUADAS.

    PubMed

    McDonald, Scott D; Brown, Whitney L; Benesek, John P; Calhoun, Patrick S

    2015-09-01

    Despite the popularity of the PTSD Checklist (PCL) as a clinical screening test, there has been no comprehensive quality review of studies evaluating its diagnostic accuracy. A systematic quality assessment of 22 diagnostic accuracy studies of the English-language PCL using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) assessment tool was conducted to examine (a) the quality of diagnostic accuracy studies of the PCL, and (b) whether quality has improved since the 2003 STAndards for the Reporting of Diagnostic accuracy studies (STARD) initiative regarding reporting guidelines for diagnostic accuracy studies. Three raters independently applied the QUADAS tool to each study, and a consensus among the 4 authors is reported. Findings indicated that although studies generally met standards in several quality areas, there is still room for improvement. Areas for improvement include establishing representativeness, adequately describing clinical and demographic characteristics of the sample, and presenting better descriptions of important aspects of test and reference standard execution. Only 2 studies met each of the 14 quality criteria. In addition, study quality has not appreciably improved since the publication of the STARD Statement in 2003. Recommendations for the improvement of diagnostic accuracy studies of the PCL are discussed. (c) 2015 APA, all rights reserved).

  5. Research on material removal accuracy analysis and correction of removal function during ion beam figuring

    NASA Astrophysics Data System (ADS)

    Wu, Weibin; Dai, Yifan; Zhou, Lin; Xu, Mingjin

    2016-09-01

    Material removal accuracy has a direct impact on the machining precision and efficiency of ion beam figuring. By analyzing the factors suppressing the improvement of material removal accuracy, we conclude that correcting the removal function deviation and reducing the removal material amount during each iterative process could help to improve material removal accuracy. Removal function correcting principle can effectively compensate removal function deviation between actual figuring and simulated processes, while experiments indicate that material removal accuracy decreases with a long machining time, so a small amount of removal material in each iterative process is suggested. However, more clamping and measuring steps will be introduced in this way, which will also generate machining errors and suppress the improvement of material removal accuracy. On this account, a free-measurement iterative process method is put forward to improve material removal accuracy and figuring efficiency by using less measuring and clamping steps. Finally, an experiment on a φ 100-mm Zerodur planar is preformed, which shows that, in similar figuring time, three free-measurement iterative processes could improve the material removal accuracy and the surface error convergence rate by 62.5% and 17.6%, respectively, compared with a single iterative process.

  6. Comparability of the effect of storage time and temperature on serum anti-Müllerian hormone measurement between original and modified enzyme-linked immunosorbent assay.

    PubMed

    Yue, Chao-Yan; Ying, Chun-Mei

    2017-01-01

    To explore the effect of modified enzyme-linked immunosorbent assay on the AMH results is increased or decreased, and to investigate the effect of storage time and temperature on AMH measurements with and without sample premixing assay buffer using the Kangrun ELISA method. Serum AMH concentration were measured by ELISA, consistency between two kits, and comparability between original and the modified assay under different stored conditions were analyzed by Passing-Bablok regression analysis and Bland-Altman bias evaluation. There was a strong consistency between AMH concentrations measured in Kangrun ELISA and Ansh Labs ultra-sensitive AMH ELISA. Pre-mixing serum specimens with assay buffer gave consistent results compared with original assay. Modified protocol can reduce the amplitude of increase affected by sample aged and give the most consistent results regardless of storage conditions. Pre-mixing protocol did not influence the results of fresh serum or frozen serum incubation <3days at 4°C and -80°C, but when specimens detected after collection and stored in other storage conditions, should be pre-mixed with assay buffer to insure its accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. AI-augmented time stretch microscopy

    NASA Astrophysics Data System (ADS)

    Mahjoubfar, Ata; Chen, Claire L.; Lin, Jiahao; Jalali, Bahram

    2017-02-01

    Cell reagents used in biomedical analysis often change behavior of the cells that they are attached to, inhibiting their native signaling. On the other hand, label-free cell analysis techniques have long been viewed as challenging either due to insufficient accuracy by limited features, or because of low throughput as a sacrifice of improved precision. We present a recently developed artificial-intelligence augmented microscope, which builds upon high-throughput time stretch quantitative phase imaging (TS-QPI) and deep learning to perform label-free cell classification with record high-accuracy. Our system captures quantitative optical phase and intensity images simultaneously by frequency multiplexing, extracts multiple biophysical features of the individual cells from these images fused, and feeds these features into a supervised machine learning model for classification. The enhanced performance of our system compared to other label-free assays is demonstrated by classification of white blood T-cells versus colon cancer cells and lipid accumulating algal strains for biofuel production, which is as much as five-fold reduction in inaccuracy. This system obtains the accuracy required in practical applications such as personalized drug development, while the cells remain intact and the throughput is not sacrificed. Here, we introduce a data acquisition scheme based on quadrature phase demodulation that enables interruptionless storage of TS-QPI cell images. Our proof of principle demonstration is capable of saving 40 TB of cell images in about four hours, i.e. pictures of every single cell in 10 mL of a sample.

  8. Classifying coastal resources by integrating optical and radar imagery and color infrared photography

    USGS Publications Warehouse

    Ramsey, Elijah W.; Nelson, Gene A.; Sapkota, Sijan

    1998-01-01

    A progressive classification of a marsh and forest system using Landsat Thematic Mapper (TM), color infrared (CIR) photograph, and ERS-1 synthetic aperture radar (SAR) data improved classification accuracy when compared to classification using solely TM reflective band data. The classification resulted in a detailed identification of differences within a nearly monotypic black needlerush marsh. Accuracy percentages of these classes were surprisingly high given the complexities of classification. The detailed classification resulted in a more accurate portrayal of the marsh transgressive sequence than was obtainable with TM data alone. Individual sensor contribution to the improved classification was compared to that using only the six reflective TM bands. Individually, the green reflective CIR and SAR data identified broad categories of water, marsh, and forest. In combination with TM, SAR and the green CIR band each improved overall accuracy by about 3% and 15% respectively. The SAR data improved the TM classification accuracy mostly in the marsh classes. The green CIR data also improved the marsh classification accuracy and accuracies in some water classes. The final combination of all sensor data improved almost all class accuracies from 2% to 70% with an overall improvement of about 20% over TM data alone. Not only was the identification of vegetation types improved, but the spatial detail of the classification approached 10 m in some areas.

  9. Evaluation of the Aptima(®) HIV-1 Quant Dx assay for HIV-1 RNA viral load detection and quantitation in plasma of HIV-1-infected individuals: A comparison with Abbott RealTime HIV-1 assay.

    PubMed

    Amendola, Alessandra; Pisciotta, Maria; Aleo, Loredana; Ferraioli, Valeria; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2016-09-01

    The Hologic Aptima(®) HIV-1 Quant Dx assay (Aptima HIV) is a real-time transcription-mediated amplification method CE-approved for use in diagnosis and monitoring of HIV-1 infection. The analytical performance of this new assay was compared to the FDA-approved Abbott RealTime HIV-1 (RealTime). The evaluation was performed using 220 clinical plasma samples, the WHO 3rd HIV-1 International Standard, and the QCMD HIV-1 RNA EQA. Concordance on qualitative results, correlation between quantitative results, accuracy, and reproducibility of viral load data were analyzed. The ability to measure HIV-1 subtypes was assessed on the second WHO International Reference Preparation Panel for HIV-1 Subtypes. With clinical samples, inter-assay agreement for qualitative results was high (91.8%) with Cohen's kappa statistic equal to 0.836. For samples with quantitative results in both assays (n = 93), Lin's concordance correlation coefficient was 0.980 (P < 0.0001) and mean differences of measurement, conducted according to Bland-Altman method, was low (0.115 log10  copies/ml). The Aptima HIV quantified the WHO 3rd HIV-1 International Standard diluted from 2000 to 31 cp/ml (5,700-88 IU/ml) at expected values with excellent linearity (R(2)  > 0.970) and showed higher sensitivity compared to RealTime being able to detect HIV-1 RNA in 10 out of 10 replicates containing down to 7 cp/ml (20 IU/ml). Reproducibility was very high, even at low HIV-1 RNA values. The Aptima HIV was able to detect and accurately quantify all the main HIV-1 subtypes in both reference panels and clinical samples. Besides excellent performance, Aptima HIV shows full automation, ease of use, and improved workflow compared to RealTime. J. Med. Virol. 88:1535-1544, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Use of multiple colorimetric indicators for paper-based microfluidic devices.

    PubMed

    Dungchai, Wijitar; Chailapakul, Orawon; Henry, Charles S

    2010-08-03

    We report here the use of multiple indicators for a single analyte for paper-based microfluidic devices (microPAD) in an effort to improve the ability to visually discriminate between analyte concentrations. In existing microPADs, a single dye system is used for the measurement of a single analyte. In our approach, devices are designed to simultaneously quantify analytes using multiple indicators for each analyte improving the accuracy of the assay. The use of multiple indicators for a single analyte allows for different indicator colors to be generated at different analyte concentration ranges as well as increasing the ability to better visually discriminate colors. The principle of our devices is based on the oxidation of indicators by hydrogen peroxide produced by oxidase enzymes specific for each analyte. Each indicator reacts at different peroxide concentrations and therefore analyte concentrations, giving an extended range of operation. To demonstrate the utility of our approach, the mixture of 4-aminoantipyrine and 3,5-dichloro-2-hydroxy-benzenesulfonic acid, o-dianisidine dihydrochloride, potassium iodide, acid black, and acid yellow were chosen as the indicators for simultaneous semi-quantitative measurement of glucose, lactate, and uric acid on a microPAD. Our approach was successfully applied to quantify glucose (0.5-20 mM), lactate (1-25 mM), and uric acid (0.1-7 mM) in clinically relevant ranges. The determination of glucose, lactate, and uric acid in control serum and urine samples was also performed to demonstrate the applicability of this device for biological sample analysis. Finally results for the multi-indicator and single indicator system were compared using untrained readers to demonstrate the improvements in accuracy achieved with the new system. 2010 Elsevier B.V. All rights reserved.

  11. Validation and Implementation of Clinical Laboratory Improvements Act-Compliant Whole-Genome Sequencing in the Public Health Microbiology Laboratory

    PubMed Central

    Kozyreva, Varvara K.; Truong, Chau-Linda; Greninger, Alexander L.; Crandall, John; Mukhopadhyay, Rituparna

    2017-01-01

    ABSTRACT Public health microbiology laboratories (PHLs) are on the cusp of unprecedented improvements in pathogen identification, antibiotic resistance detection, and outbreak investigation by using whole-genome sequencing (WGS). However, considerable challenges remain due to the lack of common standards. Here, we describe the validation of WGS on the Illumina platform for routine use in PHLs according to Clinical Laboratory Improvements Act (CLIA) guidelines for laboratory-developed tests (LDTs). We developed a validation panel comprising 10 Enterobacteriaceae isolates, 5 Gram-positive cocci, 5 Gram-negative nonfermenting species, 9 Mycobacterium tuberculosis isolates, and 5 miscellaneous bacteria. The genome coverage range was 15.71× to 216.4× (average, 79.72×; median, 71.55×); the limit of detection (LOD) for single nucleotide polymorphisms (SNPs) was 60×. The accuracy, reproducibility, and repeatability of base calling were >99.9%. The accuracy of phylogenetic analysis was 100%. The specificity and sensitivity inferred from multilocus sequence typing (MLST) and genome-wide SNP-based phylogenetic assays were 100%. The following objectives were accomplished: (i) the establishment of the performance specifications for WGS applications in PHLs according to CLIA guidelines, (ii) the development of quality assurance and quality control measures, (iii) the development of a reporting format for end users with or without WGS expertise, (iv) the availability of a validation set of microorganisms, and (v) the creation of a modular template for the validation of WGS processes in PHLs. The validation panel, sequencing analytics, and raw sequences could facilitate multilaboratory comparisons of WGS data. Additionally, the WGS performance specifications and modular template are adaptable for the validation of other platforms and reagent kits. PMID:28592550

  12. Validation and Implementation of Clinical Laboratory Improvements Act-Compliant Whole-Genome Sequencing in the Public Health Microbiology Laboratory.

    PubMed

    Kozyreva, Varvara K; Truong, Chau-Linda; Greninger, Alexander L; Crandall, John; Mukhopadhyay, Rituparna; Chaturvedi, Vishnu

    2017-08-01

    Public health microbiology laboratories (PHLs) are on the cusp of unprecedented improvements in pathogen identification, antibiotic resistance detection, and outbreak investigation by using whole-genome sequencing (WGS). However, considerable challenges remain due to the lack of common standards. Here, we describe the validation of WGS on the Illumina platform for routine use in PHLs according to Clinical Laboratory Improvements Act (CLIA) guidelines for laboratory-developed tests (LDTs). We developed a validation panel comprising 10 Enterobacteriaceae isolates, 5 Gram-positive cocci, 5 Gram-negative nonfermenting species, 9 Mycobacterium tuberculosis isolates, and 5 miscellaneous bacteria. The genome coverage range was 15.71× to 216.4× (average, 79.72×; median, 71.55×); the limit of detection (LOD) for single nucleotide polymorphisms (SNPs) was 60×. The accuracy, reproducibility, and repeatability of base calling were >99.9%. The accuracy of phylogenetic analysis was 100%. The specificity and sensitivity inferred from multilocus sequence typing (MLST) and genome-wide SNP-based phylogenetic assays were 100%. The following objectives were accomplished: (i) the establishment of the performance specifications for WGS applications in PHLs according to CLIA guidelines, (ii) the development of quality assurance and quality control measures, (iii) the development of a reporting format for end users with or without WGS expertise, (iv) the availability of a validation set of microorganisms, and (v) the creation of a modular template for the validation of WGS processes in PHLs. The validation panel, sequencing analytics, and raw sequences could facilitate multilaboratory comparisons of WGS data. Additionally, the WGS performance specifications and modular template are adaptable for the validation of other platforms and reagent kits. Copyright © 2017 Kozyreva et al.

  13. Variant effect prediction tools assessed using independent, functional assay-based datasets: implications for discovery and diagnostics.

    PubMed

    Mahmood, Khalid; Jung, Chol-Hee; Philip, Gayle; Georgeson, Peter; Chung, Jessica; Pope, Bernard J; Park, Daniel J

    2017-05-16

    Genetic variant effect prediction algorithms are used extensively in clinical genomics and research to determine the likely consequences of amino acid substitutions on protein function. It is vital that we better understand their accuracies and limitations because published performance metrics are confounded by serious problems of circularity and error propagation. Here, we derive three independent, functionally determined human mutation datasets, UniFun, BRCA1-DMS and TP53-TA, and employ them, alongside previously described datasets, to assess the pre-eminent variant effect prediction tools. Apparent accuracies of variant effect prediction tools were influenced significantly by the benchmarking dataset. Benchmarking with the assay-determined datasets UniFun and BRCA1-DMS yielded areas under the receiver operating characteristic curves in the modest ranges of 0.52 to 0.63 and 0.54 to 0.75, respectively, considerably lower than observed for other, potentially more conflicted datasets. These results raise concerns about how such algorithms should be employed, particularly in a clinical setting. Contemporary variant effect prediction tools are unlikely to be as accurate at the general prediction of functional impacts on proteins as reported prior. Use of functional assay-based datasets that avoid prior dependencies promises to be valuable for the ongoing development and accurate benchmarking of such tools.

  14. Bayesian estimation of diagnostic sensitivity and specificity of a nervous necrosis virus antibody ELISA.

    PubMed

    Jaramillo, Diana; Dürr, Salome; Hick, Paul; Whittington, Richard

    2016-01-01

    Diagnosis of nervous necrosis virus (NNV) infection in susceptible fish species is mostly performed post-mortem due to the neurotropism of the causative agent and the only validated diagnostic assays require samples from brain and retinal tissue. However, a non-lethal alternative to test for exposure of fish to NNV is needed. An indirect ELISA for the detection of anti-NNV antibodies in was recently developed and evaluated to detect responses in the sera from immunized fish. For this study, we assessed the accuracy of the assay at detecting specific antibodies from naturally exposed fish using field samples from populations with differing infection status. We applied a Bayesian model, using RTqPCR as a second test. Median estimates of the diagnostic sensitivity and specificity of the VNN ELISA were 81.8% and 86.7%, respectively. We concluded that the assay was fit for the purpose of identifying animals in naturally exposed populations. With further evaluation in larger populations the test might be used to inform implementation of control measures, and for estimating infection prevalence to facilitate risk analysis. To our knowledge this is the first report on the diagnostic accuracy of an antibody ELISA for an infectious disease in finfish. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Feasibility and accuracy evaluation of three human papillomavirus assays for FTA card-based sampling: a pilot study in cervical cancer screening.

    PubMed

    Wang, Shao-Ming; Hu, Shang-Ying; Chen, Wen; Chen, Feng; Zhao, Fang-Hui; He, Wei; Ma, Xin-Ming; Zhang, Yu-Qing; Wang, Jian; Sivasubramaniam, Priya; Qiao, You-Lin

    2015-11-04

    Liquid-state specimen carriers are inadequate for sample transportation in large-scale screening projects in low-resource settings, which necessitates the exploration of novel non-hazardous solid-state alternatives. Studies investigating the feasibility and accuracy of a solid-state human papillomavirus (HPV) sampling medium in combination with different down-stream HPV DNA assays for cervical cancer screening are needed. We collected two cervical specimens from 396 women, aged 25-65 years, who were enrolled in a cervical cancer screening trial. One sample was stored using DCM preservative solution and the other was applied to a Whatman Indicating FTA Elute® card (FTA card). All specimens were processed using three HPV testing methods, including Hybrid capture 2 (HC2), careHPV™, and Cobas®4800 tests. All the women underwent a rigorous colposcopic evaluation that included using a microbiopsy protocol. Compared to the liquid-based carrier, the FTA card demonstrated comparable sensitivity for detecting high grade Cervical Intraepithelial Neoplasia (CIN) using HC2 (91.7 %), careHPV™ (83.3 %), and Cobas®4800 (91.7 %) tests. Moreover, the FTA card showed a higher specificity compared to a liquid-based carrier for HC2 (79.5 % vs. 71.6 %, P = 0.015), comparable specificity for careHPV™ (78.1 % vs. 73.0 %, P > 0.05), but lower specificity for the Cobas®4800 test (62.4 % vs. 69.9 %, P = 0.032). Generally, the FTA card-based sampling medium's accuracy was comparable with that of liquid-based medium for the three HPV testing assays. FTA cards are a promising sample carrier for cervical cancer screening. With further optimization, it can be utilized for HPV testing in areas of varying economic development.

  16. Comparison of Phenotypic and Genotypic Methods for Detection of Diphtheria Toxin among Isolates of Pathogenic Corynebacteria

    PubMed Central

    Efstratiou, Androulla; Engler, Kathryn H.; Dawes, Charlotte S.; Sesardic, Dorothea

    1998-01-01

    We have compared molecular, immunochemical, and cytotoxic assays for the detection of diphtheria toxin from 55 isolates of Corynebacterium diphtheriae and Corynebacterium ulcerans originally isolated in five different countries. The suitabilities and accuracies of these assays for the laboratory diagnosis of diphtheria were compared and evaluated against the “gold standard” in vivo methods. The in vivo and Vero cell cytotoxicity assays were accurate in their abilities to detect diphtheria toxin but were time-consuming; however, the cytotoxicity assay is a suitable in vitro alternative to the in vivo virulence test. There was complete concordance between all the phenotypic methods. Genotypic tests based upon PCR were rapid; however, PCR must be used with caution because some isolates of C. diphtheriae possessed toxin genes but failed to express a biologically active toxin. Therefore, phenotypic confirmation of toxigenicity for the microbiological diagnosis of diphtheria is recommended. PMID:9774560

  17. Comparison of phenotypic and genotypic methods for detection of diphtheria toxin among isolates of pathogenic corynebacteria.

    PubMed

    Efstratiou, A; Engler, K H; Dawes, C S; Sesardic, D

    1998-11-01

    We have compared molecular, immunochemical, and cytotoxic assays for the detection of diphtheria toxin from 55 isolates of Corynebacterium diphtheriae and Corynebacterium ulcerans originally isolated in five different countries. The suitabilities and accuracies of these assays for the laboratory diagnosis of diphtheria were compared and evaluated against the "gold standard" in vivo methods. The in vivo and Vero cell cytotoxicity assays were accurate in their abilities to detect diphtheria toxin but were time-consuming; however, the cytotoxicity assay is a suitable in vitro alternative to the in vivo virulence test. There was complete concordance between all the phenotypic methods. Genotypic tests based upon PCR were rapid; however, PCR must be used with caution because some isolates of C. diphtheriae possessed toxin genes but failed to express a biologically active toxin. Therefore, phenotypic confirmation of toxigenicity for the microbiological diagnosis of diphtheria is recommended.

  18. An Automatic Lab-on-Disc System for Blood Typing.

    PubMed

    Chang, Yaw-Jen; Fan, Yi-Hua; Chen, Shia-Chung; Lee, Kuan-Hua; Lou, Liao-Yong

    2018-04-01

    A blood-typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This article presents a lab-on-disc blood-typing system to conduct a total of eight assays for a patient, including forward-typing tests, reverse-typing tests, and irregular-antibody tests. These assays are carried out in a microfluidic disc simultaneously. A blood-typing apparatus was designed to automatically manipulate the disc. The blood type can be determined by integrating the results of red blood cell (RBC) agglutination in the microchannels. The experimental results of our current 40 blood samples show that the results agree with those examined in the hospital. The accuracy reaches 97.5%.

  19. Fluorescent microplate assay method for high-throughput detection of lipase transesterification activity.

    PubMed

    Zheng, Jianyong; Wei, Wei; Lan, Xing; Zhang, Yinjun; Wang, Zhao

    2018-05-15

    This study describes a sensitive and fluorescent microplate assay method to detect lipase transesterification activity. Lipase-catalyzed transesterification between butyryl 4-methyl umbelliferone (Bu-4-Mu) and methanol in tert-butanol was selected as the model reaction. The release of 4-methylumbelliferone (4-Mu) in the reaction was determined by detecting the fluorescence intensity at λ ex 330 nm and λ em 390 nm. Several lipases were used to investigate the accuracy and efficiency of the proposed method. Apparent Michaelis constant (Km) was calculated for transesterification between Bu-4-Mu and methanol by the lipases. The main advantages of the assay method include high sensitivity, inexpensive reagents, and simple detection process. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. The availability of prior ECGs improves paramedic accuracy in recognizing ST-segment elevation myocardial infarction.

    PubMed

    O'Donnell, Daniel; Mancera, Mike; Savory, Eric; Christopher, Shawn; Schaffer, Jason; Roumpf, Steve

    2015-01-01

    Early and accurate identification of ST-elevation myocardial infarction (STEMI) by prehospital providers has been shown to significantly improve door to balloon times and improve patient outcomes. Previous studies have shown that paramedic accuracy in reading 12 lead ECGs can range from 86% to 94%. However, recent studies have demonstrated that accuracy diminishes for the more uncommon STEMI presentations (e.g. lateral). Unlike hospital physicians, paramedics rarely have the ability to review previous ECGs for comparison. Whether or not a prior ECG can improve paramedic accuracy is not known. The availability of prior ECGs improves paramedic accuracy in ECG interpretation. 130 paramedics were given a single clinical scenario. Then they were randomly assigned 12 computerized prehospital ECGs, 6 with and 6 without an accompanying prior ECG. All ECGs were obtained from a local STEMI registry. For each ECG paramedics were asked to determine whether or not there was a STEMI and to rate their confidence in their interpretation. To determine if the old ECGs improved accuracy we used a mixed effects logistic regression model to calculate p-values between the control and intervention. The addition of a previous ECG improved the accuracy of identifying STEMIs from 75.5% to 80.5% (p=0.015). A previous ECG also increased paramedic confidence in their interpretation (p=0.011). The availability of previous ECGs improves paramedic accuracy and enhances their confidence in interpreting STEMIs. Further studies are needed to evaluate this impact in a clinical setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. A laboratory information management system for the analysis of tritium (3H) in environmental waters.

    PubMed

    Belachew, Dagnachew Legesse; Terzer-Wassmuth, Stefan; Wassenaar, Leonard I; Klaus, Philipp M; Copia, Lorenzo; Araguás, Luis J Araguás; Aggarwal, Pradeep

    2018-07-01

    Accurate and precise measurements of low levels of tritium ( 3 H) in environmental waters are difficult to attain due to complex steps of sample preparation, electrolytic enrichment, liquid scintillation decay counting, and extensive data processing. We present a Microsoft Access™ relational database application, TRIMS (Tritium Information Management System) to assist with sample and data processing of tritium analysis by managing the processes from sample registration and analysis to reporting and archiving. A complete uncertainty propagation algorithm ensures tritium results are reported with robust uncertainty metrics. TRIMS will help to increase laboratory productivity and improve the accuracy and precision of 3 H assays. The software supports several enrichment protocols and LSC counter types. TRIMS is available for download at no cost from the IAEA at www.iaea.org/water. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Compaction of rolling circle amplification products increases signal integrity and signal-to-noise ratio

    PubMed Central

    Clausson, Carl-Magnus; Arngården, Linda; Ishaq, Omer; Klaesson, Axel; Kühnemund, Malte; Grannas, Karin; Koos, Björn; Qian, Xiaoyan; Ranefall, Petter; Krzywkowski, Tomasz; Brismar, Hjalmar; Nilsson, Mats; Wählby, Carolina; Söderberg, Ola

    2015-01-01

    Rolling circle amplification (RCA) for generation of distinct fluorescent signals in situ relies upon the self-collapsing properties of single-stranded DNA in commonly used RCA-based methods. By introducing a cross-hybridizing DNA oligonucleotide during rolling circle amplification, we demonstrate that the fluorophore-labeled RCA products (RCPs) become smaller. The reduced size of RCPs increases the local concentration of fluorophores and as a result, the signal intensity increases together with the signal-to-noise ratio. Furthermore, we have found that RCPs sometimes tend to disintegrate and may be recorded as several RCPs, a trait that is prevented with our cross-hybridizing DNA oligonucleotide. These effects generated by compaction of RCPs improve accuracy of visual as well as automated in situ analysis for RCA based methods, such as proximity ligation assays (PLA) and padlock probes. PMID:26202090

  3. Evaluation of colorimetric assays for analyzing reductively methylated proteins: Biases and mechanistic insights.

    PubMed

    Brady, Pamlea N; Macnaughtan, Megan A

    2015-12-15

    Colorimetric protein assays, such as the Coomassie blue G-250 dye-binding (Bradford) and bicinchoninic acid (BCA) assays, are commonly used to quantify protein concentration. The accuracy of these assays depends on the amino acid composition. Because of the extensive use of reductive methylation in the study of proteins and the importance of biological methylation, it is necessary to evaluate the impact of lysyl methylation on the Bradford and BCA assays. Unmodified and reductively methylated proteins were analyzed using the absorbance at 280 nm to standardize the concentrations. Using model compounds, we demonstrate that the dimethylation of lysyl ε-amines does not affect the proteins' molar extinction coefficients at 280 nm. For the Bradford assay, the responses (absorbance per unit concentration) of the unmodified and reductively methylated proteins were similar, with a slight decrease in the response upon methylation. For the BCA assay, the responses of the reductively methylated proteins were consistently higher, overestimating the concentrations of the methylated proteins. The enhanced color formation in the BCA assay may be due to the lower acid dissociation constants of the lysyl ε-dimethylamines compared with the unmodified ε-amine, favoring Cu(II) binding in biuret-like complexes. The implications for the analysis of biologically methylated samples are discussed. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Evaluation of Colorimetric Assays for Analyzing Reductively Methylated Proteins: Biases and Mechanistic Insights

    PubMed Central

    Brady, Pamlea N.; Macnaughtan, Megan A.

    2015-01-01

    Colorimetric protein assays, such as the Coomassie blue G-250 dye-binding (Bradford) and bicinchoninic acid (BCA) assays, are commonly used to quantify protein concentration. The accuracy of these assays depends on the amino acid composition. Because of the extensive use of reductive methylation in the study of proteins and the importance of biological methylation, it is necessary to evaluate the impact of lysyl methylation on the Bradford and BCA assays. Unmodified and reductively methylated proteins were analyzed using the absorbance at 280 nm to standardize the concentrations. Using model compounds, we demonstrate that the dimethylation of lysyl ε-amines does not affect the proteins’ molar extinction coefficients at 280 nm. For the Bradford assay, the response (absorbance per unit concentration) of the unmodified and reductively methylated proteins were similar with a slight decrease in the response upon methylation. For the BCA assay, the responses of the reductively methylated proteins were consistently higher, overestimating the concentrations of the methylated proteins. The enhanced color-formation in the BCA assay may be due to the lower acid dissociation constants of the lysyl ε-dimethylamines, compared to the unmodified ε-amine, favoring Cu(II) binding in biuret-like complexes. The implications for the analysis of biologically methylated samples are discussed. PMID:26342307

  5. Validation of an assay for quantification of alpha-amylase in saliva of sheep

    PubMed Central

    Fuentes-Rubio, Maria; Fuentes, Francisco; Otal, Julio; Quiles, Alberto; Hevia, María Luisa

    2016-01-01

    The objective of this study was to develop a time-resolved immunofluorometric assay (TR-IFMA) for quantification of salivary alpha-amylase in sheep. For that purpose, after the design of the assay, an analytical and a clinical validation were carried out. The analytical validation of the assay showed intra- and inter-assay coefficients of variation (CVs) of 6.1% and 10.57%, respectively and an analytical limit of detection of 0.09 ng/mL. The assay also demonstrated a high level of accuracy, as determined by linearity under dilution. For clinical validation, a model of acute stress testing was conducted to determine whether expected significant changes in alpha-amylase were picked up in the newly developed assay. In that model, 11 sheep were immobilized and confronted with a sheepdog to induce stress. Saliva samples were obtained before stress induction and 15, 30, and 60 min afterwards. Salivary cortisol was measured as a reference of stress level. The results of TR-IFMA showed a significant increase (P < 0.01) in the concentration of alpha-amylase in saliva after stress induction. The assay developed in this study could be used to measure salivary alpha-amylase in the saliva of sheep and this enzyme could be a possible noninvasive biomarker of stress in sheep. PMID:27408332

  6. Suitability of a liquid chromatography assay of neomycin sulfate to replace the microbiological assay for neomycin in USP Monographs.

    PubMed

    Hanko, Valoran P; Rohrer, Jeffrey S

    2010-01-05

    The current USP National Formulary contains 65 Monographs for drug formulations containing neomycin. All 65 Monographs prescribe a bioassay for neomycin assay. This bioassay, based on cell culture, is labor intensive, has poor precision, and cannot be adapted for purity or identification. High-performance anion-exchange chromatography with integrated pulsed amperometric detection (HPAE-IPAD), a liquid chromatography technique, has been shown to be suitable for neomycin purity analysis and neomycin assay of an over-the-counter first aid cream (Hanko and Rohrer [17]). Here we propose that an HPAE-IPAD assay can replace the bioassay in the 65 neomycin-containing Monographs. We applied the HPAE-IPAD assay to four neomycin-containing drug products representing the four classes of formulations found in the 65 Monographs, liquid, solid, suspension, and cream. Each drug was analyzed with two chromatography systems, and on 3 separate days. For all products, HPAE-IPAD measurements were precise and accurate with respect to the label concentrations. There was also high accuracy for spike recovery of neomycin from the four drug products throughout 70-150% of the labeled concentration. These results suggest that an HPAE-IPAD assay would be an accurate assay for neomycin, and would be faster and more precise than the current bioassay.

  7. GMO detection in food and feed through screening by visual loop-mediated isothermal amplification assays.

    PubMed

    Wang, Cong; Li, Rong; Quan, Sheng; Shen, Ping; Zhang, Dabing; Shi, Jianxin; Yang, Litao

    2015-06-01

    Isothermal DNA/RNA amplification techniques are the primary methodology for developing on-spot rapid nucleic acid amplification assays, and the loop-mediated isothermal amplification (LAMP) technique has been developed and applied in the detection of foodborne pathogens, plant/animal viruses, and genetically modified (GM) food/feed contents. In this study, one set of LAMP assays targeting on eight frequently used universal elements, marker genes, and exogenous target genes, such as CaMV35S promoter, FMV35S promoter, NOS, bar, cry1Ac, CP4 epsps, pat, and NptII, were developed for visual screening of GM contents in plant-derived food samples with high efficiency and accuracy. For these eight LAMP assays, their specificity was evaluated by testing commercial GM plant events and their limits of detection were also determined, which are 10 haploid genome equivalents (HGE) for FMV35S promoter, cry1Ac, and pat assays, as well as five HGE for CaMV35S promoter, bar, NOS terminator, CP4 epsps, and NptII assays. The screening applicability of these LAMP assays was further validated successfully using practical canola, soybean, and maize samples. The results suggested that the established visual LAMP assays are applicable and cost-effective for GM screening in plant-derived food samples.

  8. Commercial enzyme-linked immunosorbent assay versuspolymerase chain reaction for the diagnosis of chronic Chagas disease: a systematic review and meta-analysis.

    PubMed

    Brasil, Pedro Emmanuel Alvarenga Americano do; Castro, Rodolfo; Castro, Liane de

    2016-01-01

    Chronic Chagas disease diagnosis relies on laboratory tests due to its clinical characteristics. The aim of this research was to review commercial enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR) diagnostic test performance. Performance of commercial ELISA or PCR for the diagnosis of chronic Chagas disease were systematically searched in PubMed, Scopus, Embase, ISI Web, and LILACS through the bibliography from 1980-2014 and by contact with the manufacturers. The risk of bias was assessed with QUADAS-2. Heterogeneity was estimated with the I2 statistic. Accuracies provided by the manufacturers usually overestimate the accuracy provided by academia. The risk of bias is high in most tests and in most QUADAS dimensions. Heterogeneity is high in either sensitivity, specificity, or both. The evidence regarding commercial ELISA and ELISA-rec sensitivity and specificity indicates that there is overestimation. The current recommendation to use two simultaneous serological tests can be supported by the risk of bias analysis and the amount of heterogeneity but not by the observed accuracies. The usefulness of PCR tests are debatable and health care providers should not order them on a routine basis. PCR may be used in selected cases due to its potential to detect seronegative subjects.

  9. Commercial enzyme-linked immunosorbent assay versus polymerase chain reaction for the diagnosis of chronic Chagas disease: a systematic review and meta-analysis

    PubMed Central

    do Brasil, Pedro Emmanuel Alvarenga Americano; Castro, Rodolfo; de Castro, Liane

    2016-01-01

    Chronic Chagas disease diagnosis relies on laboratory tests due to its clinical characteristics. The aim of this research was to review commercial enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR) diagnostic test performance. Performance of commercial ELISA or PCR for the diagnosis of chronic Chagas disease were systematically searched in PubMed, Scopus, Embase, ISI Web, and LILACS through the bibliography from 1980-2014 and by contact with the manufacturers. The risk of bias was assessed with QUADAS-2. Heterogeneity was estimated with the I2 statistic. Accuracies provided by the manufacturers usually overestimate the accuracy provided by academia. The risk of bias is high in most tests and in most QUADAS dimensions. Heterogeneity is high in either sensitivity, specificity, or both. The evidence regarding commercial ELISA and ELISA-rec sensitivity and specificity indicates that there is overestimation. The current recommendation to use two simultaneous serological tests can be supported by the risk of bias analysis and the amount of heterogeneity but not by the observed accuracies. The usefulness of PCR tests are debatable and health care providers should not order them on a routine basis. PCR may be used in selected cases due to its potential to detect seronegative subjects. PMID:26814640

  10. A comparison of two antigen-detection ELISA for detecting infection of Dirofilaria immitis in dogs.

    PubMed

    Euclid, J M; Copeman, D B

    1997-09-01

    A survey on 87 dogs necropsied in the Townsville region revealed 34 (39%) were infected with Dirofilaria immitis. Infected dogs had an average of 6.1 adult worms in the heart and associated blood vessels. The VetRED assay detected 23 of the 34 infected dogs (sensitivity 65%) and the Og4C3 ELISA detected 27 (sensitivity 80%). Sensitivity of the VetRED and Og4C3 ELISA increased to 88 and 94% respectively in dogs with three or more worms. Both tests detected correctly all uninfected dogs. Despite the higher accuracy of the Og4C3 ELISA, compared to the VetRED assay, it is unlikely to be used widely as a field test for heartworm unless it can be modified from its present plate ELISA format which takes 4 hours, into one which is more rapid and convenient. However, as a reference ELISA, it may well be worthwhile in situations which require considerable accuracy for detecting D. immitis infection.

  11. A novel spectrofluorimetric method for the assay of pseudoephedrine hydrochloride in pharmaceutical formulations via derivatization with 4-chloro-7-nitrobenzofurazan.

    PubMed

    El-Didamony, Akram M; Gouda, Ayman A

    2011-01-01

    A new highly sensitive and specific spectrofluorimetric method has been developed to determine a sympathomimetic drug pseudoephedrine hydrochloride. The present method was based on derivatization with 4-chloro-7-nitrobenzofurazan in phosphate buffer at pH 7.8 to produce a highly fluorescent product which was measured at 532 nm (excitation at 475 nm). Under the optimized conditions a linear relationship and good correlation was found between the fluorescence intensity and pseudoephedrine hydrochloride concentration in the range of 0.5-5 µg mL(-1). The proposed method was successfully applied to the assay of pseudoephedrine hydrochloride in commercial pharmaceutical formulations with good accuracy and precision and without interferences from common additives. Statistical comparison of the results with a well-established method showed excellent agreement and proved that there was no significant difference in the accuracy and precision. The stoichiometry of the reaction was determined and the reaction pathway was postulated. Copyright © 2010 John Wiley & Sons, Ltd.

  12. Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foals.

    PubMed

    Davis, Rachel; Giguère, Steeve

    2005-11-15

    To determine and compare sensitivity, specificity, accuracy, and predictive values of measurement of serum total protein concentration by refractometry as well as 5 commercially available kits for the diagnosis of failure of passive transfer (FPT) of immunity in foals. Prospective study. 65 foals with various medical problems and 35 clinically normal foals. IgG concentration in serum was assessed by use of zinc sulfate turbidity (assay C), glutaraldehyde coagulation (assay D), 2 semiquantitative immunoassays (assays F and G), and a quantitative immunoassay (assay H). Serum total protein concentration was assessed by refractometry. Radial immunodiffusion (assays A and B) was used as the reference method. For detection of IgG < 400 mg/dL, sensitivity of assay H (100%) was not significantly different from that of assays C, E, and G (88.9%). Specificity of assays H (96.0%) and G (95.8%) was significantly higher than that of assays C (79.4%) and E (78.1 %). For detection of IgG < 800 mg/dL, sensitivities of assays H (976%), D (92.9%), C (81.0%), and G (81.0%) were significantly higher than that of assay F (52.4%). Specificity of assays F (100%), G (94.7%), and H (82.8%) was significantly higher than that of assays C (56.9%) and D (58.6%). Serum total protein concentration < or = 4.5 g/dL was suggestive of FPT, whereas values > or = 6.0 g/dL indicated adequate IgG concentrations. Most assays were adequate as initial screening tests. However, their use as a definitive test would result in unnecessary treatment of foals with adequate IgG concentrations.

  13. Improved HPLC method with the aid of chemometric strategy: determination of loxoprofen in pharmaceutical formulation.

    PubMed

    Venkatesan, P; Janardhanan, V Sree; Muralidharan, C; Valliappan, K

    2012-06-01

    Loxoprofen belongs to a class of Nonsteroidal anti-inflammatory drug acts by inhibiting isoforms of cyclo-oxygenase 1 and 2. In this study an improved RP-HPLC method was developed for the quantification of loxoprofen in pharmaceutical dosage form. For that purpose an experimental design approach was employed. Factors-independent variables (organic modifier, pH of the mobile phase and flow rate) were extracted from the preliminary study and as dependent variables three responses (loxoprofen retention factor, resolution between loxoprofen probenecid and retention time of probenecid) were selected. For the improvement of method development and optimization step, Derringer's desirability function was applied to simultaneously optimize the chosen three responses. The procedure allowed deduction of optimal conditions and the predicted optimum was acetonitrile: water (53:47, v/v), pH of the mobile phase adjusted at to 2.9 with ortho phosphoric acid. The separation was achieved in less than 4minutes. The method was applied in the quality control of commercial tablets. The method showed good agreement between the experimental data and predictive value throughout the studied parameter space. The optimized assay condition was validated according to International conference on harmonisation guidelines to confirm specificity, linearity, accuracy and precision.

  14. Feature instructions improve face-matching accuracy

    PubMed Central

    Bindemann, Markus

    2018-01-01

    Identity comparisons of photographs of unfamiliar faces are prone to error but important for applied settings, such as person identification at passport control. Finding techniques to improve face-matching accuracy is therefore an important contemporary research topic. This study investigated whether matching accuracy can be improved by instruction to attend to specific facial features. Experiment 1 showed that instruction to attend to the eyebrows enhanced matching accuracy for optimized same-day same-race face pairs but not for other-race faces. By contrast, accuracy was unaffected by instruction to attend to the eyes, and declined with instruction to attend to ears. Experiment 2 replicated the eyebrow-instruction improvement with a different set of same-race faces, comprising both optimized same-day and more challenging different-day face pairs. These findings suggest that instruction to attend to specific features can enhance face-matching accuracy, but feature selection is crucial and generalization across face sets may be limited. PMID:29543822

  15. Improved accuracy and precision of tracer kinetic parameters by joint fitting to variable flip angle and dynamic contrast enhanced MRI data.

    PubMed

    Dickie, Ben R; Banerji, Anita; Kershaw, Lucy E; McPartlin, Andrew; Choudhury, Ananya; West, Catharine M; Rose, Chris J

    2016-10-01

    To improve the accuracy and precision of tracer kinetic model parameter estimates for use in dynamic contrast enhanced (DCE) MRI studies of solid tumors. Quantitative DCE-MRI requires an estimate of precontrast T1 , which is obtained prior to fitting a tracer kinetic model. As T1 mapping and tracer kinetic signal models are both a function of precontrast T1 it was hypothesized that its joint estimation would improve the accuracy and precision of both precontrast T1 and tracer kinetic model parameters. Accuracy and/or precision of two-compartment exchange model (2CXM) parameters were evaluated for standard and joint fitting methods in well-controlled synthetic data and for 36 bladder cancer patients. Methods were compared under a number of experimental conditions. In synthetic data, joint estimation led to statistically significant improvements in the accuracy of estimated parameters in 30 of 42 conditions (improvements between 1.8% and 49%). Reduced accuracy was observed in 7 of the remaining 12 conditions. Significant improvements in precision were observed in 35 of 42 conditions (between 4.7% and 50%). In clinical data, significant improvements in precision were observed in 18 of 21 conditions (between 4.6% and 38%). Accuracy and precision of DCE-MRI parameter estimates are improved when signal models are fit jointly rather than sequentially. Magn Reson Med 76:1270-1281, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  16. Quality improvement of International Classification of Diseases, 9th revision, diagnosis coding in radiation oncology: single-institution prospective study at University of California, San Francisco.

    PubMed

    Chen, Chien P; Braunstein, Steve; Mourad, Michelle; Hsu, I-Chow J; Haas-Kogan, Daphne; Roach, Mack; Fogh, Shannon E

    2015-01-01

    Accurate International Classification of Diseases (ICD) diagnosis coding is critical for patient care, billing purposes, and research endeavors. In this single-institution study, we evaluated our baseline ICD-9 (9th revision) diagnosis coding accuracy, identified the most common errors contributing to inaccurate coding, and implemented a multimodality strategy to improve radiation oncology coding. We prospectively studied ICD-9 coding accuracy in our radiation therapy--specific electronic medical record system. Baseline ICD-9 coding accuracy was obtained from chart review targeting ICD-9 coding accuracy of all patients treated at our institution between March and June of 2010. To improve performance an educational session highlighted common coding errors, and a user-friendly software tool, RadOnc ICD Search, version 1.0, for coding radiation oncology specific diagnoses was implemented. We then prospectively analyzed ICD-9 coding accuracy for all patients treated from July 2010 to June 2011, with the goal of maintaining 80% or higher coding accuracy. Data on coding accuracy were analyzed and fed back monthly to individual providers. Baseline coding accuracy for physicians was 463 of 661 (70%) cases. Only 46% of physicians had coding accuracy above 80%. The most common errors involved metastatic cases, whereby primary or secondary site ICD-9 codes were either incorrect or missing, and special procedures such as stereotactic radiosurgery cases. After implementing our project, overall coding accuracy rose to 92% (range, 86%-96%). The median accuracy for all physicians was 93% (range, 77%-100%) with only 1 attending having accuracy below 80%. Incorrect primary and secondary ICD-9 codes in metastatic cases showed the most significant improvement (10% vs 2% after intervention). Identifying common coding errors and implementing both education and systems changes led to significantly improved coding accuracy. This quality assurance project highlights the potential problem of ICD-9 coding accuracy by physicians and offers an approach to effectively address this shortcoming. Copyright © 2015. Published by Elsevier Inc.

  17. Opportunities for Improved Serodiagnosis of Human Tuberculosis, Bovine Tuberculosis, and Paratuberculosis

    PubMed Central

    Wadhwa, Ashutosh; Hickling, Graham J.; Eda, Shigetoshi

    2012-01-01

    Mycobacterial infections—tuberculosis (TB), bovine tuberculosis (bTB), and Johne's disease (JD)—are major infectious diseases of both human and animals. Methods presently in use for diagnosis of mycobacterial infections include bacterial culture, nucleic acid amplification, tuberculin skin test, interferon-γ assay, and serology. Serological tests have several advantages over other methods, including short turn-around time, relatively simple procedures, and low cost. However, current serodiagnostic methods for TB, bTB and JD exhibit low sensitivity and/or specificity. Recent studies that have aimed to develop improved serodiagnostic tests have mostly focused on identifying useful species-specific protein antigens. A review of recent attempts to improve diagnostic test performance indicates that the use of multiple antigens can improve the accuracy of serodiagnosis of these mycobacterial diseases. Mycobacteria also produce a variety of species-specific nonprotein molecules; however, only a few such molecules (e.g., cord factor and lipoarabinomannan) have so far been evaluated for their effectiveness as diagnostic antigens. For TB and bTB, there has been recent progress in developing laboratory-free diagnostic methods. New technologies such as microfluidics and “Lab-on-Chip” are examples of promising new technologies that can underpin development of laboratory-free diagnostic devices for these mycobacterial infections. PMID:22720192

  18. HIV-1 tropism testing in subjects achieving undetectable HIV-1 RNA: diagnostic accuracy, viral evolution and compartmentalization.

    PubMed

    Pou, Christian; Codoñer, Francisco M; Thielen, Alexander; Bellido, Rocío; Pérez-Álvarez, Susana; Cabrera, Cecilia; Dalmau, Judith; Curriu, Marta; Lie, Yolanda; Noguera-Julian, Marc; Puig, Jordi; Martínez-Picado, Javier; Blanco, Julià; Coakley, Eoin; Däumer, Martin; Clotet, Bonaventura; Paredes, Roger

    2013-01-01

    Technically, HIV-1 tropism can be evaluated in plasma or peripheral blood mononuclear cells (PBMCs). However, only tropism testing of plasma HIV-1 has been validated as a tool to predict virological response to CCR5 antagonists in clinical trials. The preferable tropism testing strategy in subjects with undetectable HIV-1 viremia, in whom plasma tropism testing is not feasible, remains uncertain. We designed a proof-of-concept study including 30 chronically HIV-1-infected individuals who achieved HIV-1 RNA <50 copies/mL during at least 2 years after first-line ART initiation. First, we determined the diagnostic accuracy of 454 and population sequencing of gp120 V3-loops in plasma and PBMCs, as well as of MT-2 assays before ART initiation. The Enhanced Sensitivity Trofile Assay (ESTA) was used as the technical reference standard. 454 sequencing of plasma viruses provided the highest agreement with ESTA. The accuracy of 454 sequencing decreased in PBMCs due to reduced specificity. Population sequencing in plasma and PBMCs was slightly less accurate than plasma 454 sequencing, being less sensitive but more specific. MT-2 assays had low sensitivity but 100% specificity. Then, we used optimized 454 sequence data to investigate viral evolution in PBMCs during viremia suppression and only found evolution of R5 viruses in one subject. No de novo CXCR4-using HIV-1 production was observed over time. Finally, Slatkin-Maddison tests suggested that plasma and cell-associated V3 forms were sometimes compartmentalized. The absence of tropism shifts during viremia suppression suggests that, when available, testing of stored plasma samples is generally safe and informative, provided that HIV-1 suppression is maintained. Tropism testing in PBMCs may not necessarily produce equivalent biological results to plasma, because the structure of viral populations and the diagnostic performance of tropism assays may sometimes vary between compartments. Thereby, proviral DNA tropism testing should be specifically validated in clinical trials before it can be applied to routine clinical decision-making.

  19. Clinical accuracy of a PLEX-ID flu device for simultaneous detection and identification of influenza viruses A and B.

    PubMed

    Tang, Yi-Wei; Lowery, Kristin S; Valsamakis, Alexandra; Schaefer, Virginia C; Chappell, James D; White-Abell, Jill; Quinn, Criziel D; Li, Haijing; Washington, Cicely A; Cromwell, Jenna; Giamanco, Chantel M; Forman, Michael; Holden, Jeffery; Rothman, Richard E; Parker, Michelle L; Ortenberg, Elaine V; Zhang, Lei; Lin, Yea-Lin; Gaydos, Charlotte A

    2013-01-01

    Respiratory tract infections caused by influenza A and B viruses often present nonspecifically, and a rapid, high-throughput laboratory technique that can identify influenza viruses is clinically and epidemiologically desirable. The PLEX-ID Flu assay (Abbott Molecular Inc., Des Plaines, IL) incorporates multilocus PCR and electrospray ionization-mass spectrometry to detect and differentiate influenza A 2009 H1N1 (H1N1-p), seasonal H1N1 (H1N1-s), influenza A H3N2, and influenza B viruses in nasopharyngeal swab (NPS) specimens. The clinical performance characteristics of the PLEX-ID Flu assay in symptomatic patients were determined in this multicenter trial. A total of 2,617 prospectively and retrospectively collected NPS specimens from patients with influenza-like illness between February 2008 and 28 May 2010 were eligible for inclusion in the study. Each specimen was tested in parallel by the PLEX-ID Flu assay and by the Prodesse ProFLU+ assay (Prodesse Inc., Madison, WI), to detect influenza A and B viruses. Specimens testing positive for influenza A virus by ProFLU+ were subtyped as H1N1-p, H1N1-s, or H3N2 by using the ProFAST+ assay (Gen-Probe Prodesse Inc.). The reproducibility of the PLEX-ID Flu assay ranged from 98.3 to 100.0%, as determined by testing a nine-specimen panel at three clinical sites on each of 5 days. Positive percent agreements (PPAs) and negative percent agreements (NPAs) of the PLEX-ID Flu assay were 94.5% and 99.0% for influenza A virus and 96.0% and 99.9% for influenza B virus, respectively. For the influenza A virus subtyping characterization, the PLEX-ID Flu assay had PPAs and NPAs of 98.3% and 97.5% for H1N1-p, 88.6% and 100.0% for H1N1-s, and 98.0% and 99.9% for H3N2, respectively. The overall agreements between the PLEX-ID and Prodesse ProFLU+/ProFAST+ assays were 97.1 to 100.0%. Bidirectional Sanger sequencing analysis revealed that 87.5% of 96 discrepant results between the PLEX-ID Flu and ProFLU+/ProFAST+ assays were found upon influenza A virus detection and H1N1-p subtyping. The PLEX-ID Flu assay demonstrated a high level of accuracy for the simultaneous detection and identification of influenza A and B viruses in patient specimens, providing a new laboratory tool for the rapid diagnosis and management of influenza A and B virus infections.

  20. The Spheroplast Lysis Assay for Yeast in Microtiter Plate Format

    PubMed Central

    Ovalle, Rafael; Spencer, Moyah; Thiwanont, Monthiwa; Lipke, Peter N.

    1999-01-01

    A yeast lysis assay in the microtiter plate format improved precision and throughput and led to an improved algorithm for estimating lag time. The assay reproducibly revealed differences of 10% or greater in the maximal lysis rate and 50% or greater in the lag time. Clonal differences were determined to be the major source of variation. Microtiter-based assays should be useful for screening for drug susceptibility and for analyzing mutant phenotypes. PMID:10427014

  1. A Retrospective Assessment of Four Antigen Assays for the Detection of Invasive Candidiasis Among High-Risk Hospitalized Patients.

    PubMed

    Hartl, Barbara; Zeller, Iris; Manhart, Angelika; Selitsch, Brigitte; Lass-Flörl, Cornelia; Willinger, Birgit

    2018-06-01

    Because of their high mortality rates and non-specific symptoms, invasive Candida infections pose a huge diagnostic and therapeutic challenge. In this study, we evaluated the three mannan antigen assays Platelia, Platelia Plus and Serion, and the (1-3)-β-D-glucan assay Fungitell in a group of high-risk (hematological and surgical) patients. Test results of 305 patients hospitalized at the Vienna General Hospital and the University Hospital of Innsbruck were retrospectively analyzed. We assessed the test accuracy by means of descriptive statistics. Nine (2.95%) patients were affected by invasive candidiasis (IC), and 25 (8.2%) patients had a probable/possible infection. The majority of patients (271; 88.9%) showed no signs of infection. The Platelia and Serion mannan assays had a low sensitivity (65% and 52%, respectively), but high specificity (98% for both tests). The newer version of the Platelia assay, the Platelia Plus, had a higher sensitivity (85%) but a lower specificity (89%). The sensitivity of the Fungitell assay was high (100%), while its specificity was low (58%). The positive predictive values were 0.48 for the Platelia and 0.41 for the Serion assay, 0.26 for the Platelia Plus and 0.09 for the Fungitell assay. Our limited, retrospective study suggests the efficacy of mannan assays as screening (Platelia Plus) and confirmatory (Serion) tests, while the Fungitell assay can be used to exclude invasive Candida infections.

  2. A novel fluorescence-based assay for the rapid detection and quantification of cellular deoxyribonucleoside triphosphates

    PubMed Central

    Wilson, Peter M.; LaBonte, Melissa J.; Russell, Jared; Louie, Stan; Ghobrial, Andrew A.; Ladner, Robert D.

    2011-01-01

    Current methods for measuring deoxyribonucleoside triphosphates (dNTPs) employ reagent and labor-intensive assays utilizing radioisotopes in DNA polymerase-based assays and/or chromatography-based approaches. We have developed a rapid and sensitive 96-well fluorescence-based assay to quantify cellular dNTPs utilizing a standard real-time PCR thermocycler. This assay relies on the principle that incorporation of a limiting dNTP is required for primer-extension and Taq polymerase-mediated 5–3′ exonuclease hydrolysis of a dual-quenched fluorophore-labeled probe resulting in fluorescence. The concentration of limiting dNTP is directly proportional to the fluorescence generated. The assay demonstrated excellent linearity (R2 > 0.99) and can be modified to detect between ∼0.5 and 100 pmol of dNTP. The limits of detection (LOD) and quantification (LOQ) for all dNTPs were defined as <0.77 and <1.3 pmol, respectively. The intra-assay and inter-assay variation coefficients were determined to be <4.6% and <10%, respectively with an accuracy of 100 ± 15% for all dNTPs. The assay quantified intracellular dNTPs with similar results obtained from a validated LC–MS/MS approach and successfully measured quantitative differences in dNTP pools in human cancer cells treated with inhibitors of thymidylate metabolism. This assay has important application in research that investigates the influence of pathological conditions or pharmacological agents on dNTP biosynthesis and regulation. PMID:21576234

  3. Variability of cytokine gene expression in intestinal tissue and the impact of normalization with the use of reference genes.

    PubMed

    McGowan, Ian; Janocko, Laura; Burneisen, Shaun; Bhat, Anand; Richardson-Harman, Nicola

    2015-01-01

    To determine the intra- and inter-subject variability of mucosal cytokine gene expression in rectal biopsies from healthy volunteers and to screen cytokine and chemokine mRNA as potential biomarkers of mucosal inflammation. Rectal biopsies were collected from 8 participants (3 biopsies per participant) and 1 additional participant (10 biopsies). Quantitative reverse transcription polymerase chain reaction (RT-qPCR) was used to quantify IL-1β, IL-6, IL-12p40, IL-8, IFN-γ, MIP-1α, MIP-1β, RANTES, and TNF-α gene expression in the rectal tissue. The intra-assay, inter-biopsy and inter-subject variance was measured in the eight participants. Bootstrap re-sampling of the biopsy measurements was performed to determine the accuracy of gene expression data obtained for 10 biopsies obtained from one participant. Cytokines were both non-normalized and normalized using four reference genes (GAPDH, β-actin, β2 microglobulin, and CD45). Cytokine measurement accuracy was increased with the number of biopsy samples, per person; four biopsies were typically needed to produce a mean result within a 95% confidence interval of the subject's cytokine level approximately 80% of the time. Intra-assay precision (% geometric standard deviation) ranged between 8.2 and 96.9 with high variance between patients and even between different biopsies from the same patient. Variability was not greatly reduced with the use of reference genes to normalize data. The number of biopsy samples required to provide an accurate result varied by target although 4 biopsy samples per subject and timepoint, provided for >77% accuracy across all targets tested. Biopsies within the same subjects and between subjects had similar levels of variance while variance within a biopsy (intra-assay) was generally lower. Normalization of inflammatory cytokines against reference genes failed to consistently reduce variance. The accuracy and reliability of mRNA expression of inflammatory cytokines will set a ceiling on the ability of these measures to predict mucosal inflammation. Techniques to reduce variability should be developed within a larger cohort of individuals before normative reference values can be validated. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Multivariate Models for Prediction of Human Skin Sensitization Hazard

    PubMed Central

    Strickland, Judy; Zang, Qingda; Paris, Michael; Lehmann, David M.; Allen, David; Choksi, Neepa; Matheson, Joanna; Jacobs, Abigail; Casey, Warren; Kleinstreuer, Nicole

    2016-01-01

    One of ICCVAM’s top priorities is the development and evaluation of non-animal approaches to identify potential skin sensitizers. The complexity of biological events necessary to produce skin sensitization suggests that no single alternative method will replace the currently accepted animal tests. ICCVAM is evaluating an integrated approach to testing and assessment based on the adverse outcome pathway for skin sensitization that uses machine learning approaches to predict human skin sensitization hazard. We combined data from three in chemico or in vitro assays—the direct peptide reactivity assay (DPRA), human cell line activation test (h-CLAT), and KeratinoSens™ assay—six physicochemical properties, and an in silico read-across prediction of skin sensitization hazard into 12 variable groups. The variable groups were evaluated using two machine learning approaches, logistic regression (LR) and support vector machine (SVM), to predict human skin sensitization hazard. Models were trained on 72 substances and tested on an external set of 24 substances. The six models (three LR and three SVM) with the highest accuracy (92%) used: (1) DPRA, h-CLAT, and read-across; (2) DPRA, h-CLAT, read-across, and KeratinoSens; or (3) DPRA, h-CLAT, read-across, KeratinoSens, and log P. The models performed better at predicting human skin sensitization hazard than the murine local lymph node assay (accuracy = 88%), any of the alternative methods alone (accuracy = 63–79%), or test batteries combining data from the individual methods (accuracy = 75%). These results suggest that computational methods are promising tools to effectively identify potential human skin sensitizers without animal testing. PMID:27480324

  5. Laboratory and clinical aspects of human papillomavirus testing

    PubMed Central

    Chan, Paul K.S.; Picconi, María Alejandra; Cheung, Tak Hong; Giovannelli, Lucia; Park, Jong Sup

    2012-01-01

    Human papillomavirus (HPV) infection is associated with a wide spectrum of disease that ranges from self-limited skin warts to life-threatening cancers. Since HPV plays a necessary etiological role in cervical cancer, it is logical to use HPV as a marker for early detection of cervical cancer and precancer. Recent advances in technology enable the development of high-throughput HPV assays of different formats, including DNA-based, mRNA-based, high-risk group-specific and type-specific methods. The ultimate goal of these assays is to improve the accuracy and cost-effiectiveness of cervical screening programs. HPV testing has several potential advantages compared to cytology-based screening. However, since the cancer to transient infection ratio is always low in the general population, HPV test results are bound to have a low positive predictive value that may subject women to unnecessary follow-up investigations. The wide-spread administration of prophylactic HPV vaccine will substantially decrease the incidence of cancer and precancer. This poses a number of challenges to cytology-based screening, and the role of HPV testing is expected to increase. Finally, apart from technical and cost-effiectiveness considerations, one should also keep in mind the psycho-social impact of using sexually-transmitted agents as a marker for cancer screening. PMID:22913405

  6. A comprehensive statistical classifier of foci in the cell transformation assay for carcinogenicity testing.

    PubMed

    Callegaro, Giulia; Malkoc, Kasja; Corvi, Raffaella; Urani, Chiara; Stefanini, Federico M

    2017-12-01

    The identification of the carcinogenic risk of chemicals is currently mainly based on animal studies. The in vitro Cell Transformation Assays (CTAs) are a promising alternative to be considered in an integrated approach. CTAs measure the induction of foci of transformed cells. CTAs model key stages of the in vivo neoplastic process and are able to detect both genotoxic and some non-genotoxic compounds, being the only in vitro method able to deal with the latter. Despite their favorable features, CTAs can be further improved, especially reducing the possible subjectivity arising from the last phase of the protocol, namely visual scoring of foci using coded morphological features. By taking advantage of digital image analysis, the aim of our work is to translate morphological features into statistical descriptors of foci images, and to use them to mimic the classification performances of the visual scorer to discriminate between transformed and non-transformed foci. Here we present a classifier based on five descriptors trained on a dataset of 1364 foci, obtained with different compounds and concentrations. Our classifier showed accuracy, sensitivity and specificity equal to 0.77 and an area under the curve (AUC) of 0.84. The presented classifier outperforms a previously published model. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Research on navigation of satellite constellation based on an asynchronous observation model using X-ray pulsar

    NASA Astrophysics Data System (ADS)

    Guo, Pengbin; Sun, Jian; Hu, Shuling; Xue, Ju

    2018-02-01

    Pulsar navigation is a promising navigation method for high-altitude orbit space tasks or deep space exploration. At present, an important reason for restricting the development of pulsar navigation is that navigation accuracy is not high due to the slow update of the measurements. In order to improve the accuracy of pulsar navigation, an asynchronous observation model which can improve the update rate of the measurements is proposed on the basis of satellite constellation which has a broad space for development because of its visibility and reliability. The simulation results show that the asynchronous observation model improves the positioning accuracy by 31.48% and velocity accuracy by 24.75% than that of the synchronous observation model. With the new Doppler effects compensation method in the asynchronous observation model proposed in this paper, the positioning accuracy is improved by 32.27%, and the velocity accuracy is improved by 34.07% than that of the traditional method. The simulation results show that without considering the clock error will result in a filtering divergence.

  8. Simultaneous ultramicroanalysis of both 17-keto-and 17beta-hydroxy androgens in biological fluids.

    PubMed

    Ganjam, V K

    1976-11-01

    Sensitive methods for quantifying androgens were lacking. Therefore, a relatively simple procedure for separating steroids was combined with highly specific assay methods so that eight androgens could be measured with high accuracy, precision and sensitivity. Semi-automated separations on Sephadex LH-20 columns used heptane:methylene chloride:ethanol:water (50:50:1:0.12) and a flow rate of 17.0 min/ml. The six peaks eluted contained androstenedine; androsterone, epiandrosterone and dihydrotestosterone; testosterone and dehydroepiandrosterone; 3alpha-androstanediol; 3beta-androstanediol; and androstenediol. Androstenedione, dehydroepiandrosterone and androstenediol were quantified using specific antisera (sensitivity less than or equal to 75 pg). Testosterone and dihydrotestosterone were measured by competitive protein-binding assays using rabbit TeBG (sensitivity less than or equal to 150 pg). 3alpha- and 3beta-androstanediol were similarly assayed using human TeBG (sensitivity approximately 150 pg). Androsterone was reduced with NaBH4 and the resulting 3alpha-androstanediol was assayed using human TeBG (sensitivity approximately 200 pg). Inter- and intra-assay variations were less than 10% for radioimmunoassays and less than 16% for competitive protein-binding assays over the entire dose response curve.

  9. Development and Evaluation of a Parallel Reaction Monitoring Strategy for Large-Scale Targeted Metabolomics Quantification.

    PubMed

    Zhou, Juntuo; Liu, Huiying; Liu, Yang; Liu, Jia; Zhao, Xuyang; Yin, Yuxin

    2016-04-19

    Recent advances in mass spectrometers which have yielded higher resolution and faster scanning speeds have expanded their application in metabolomics of diverse diseases. Using a quadrupole-Orbitrap LC-MS system, we developed an efficient large-scale quantitative method targeting 237 metabolites involved in various metabolic pathways using scheduled, parallel reaction monitoring (PRM). We assessed the dynamic range, linearity, reproducibility, and system suitability of the PRM assay by measuring concentration curves, biological samples, and clinical serum samples. The quantification performances of PRM and MS1-based assays in Q-Exactive were compared, and the MRM assay in QTRAP 6500 was also compared. The PRM assay monitoring 237 polar metabolites showed greater reproducibility and quantitative accuracy than MS1-based quantification and also showed greater flexibility in postacquisition assay refinement than the MRM assay in QTRAP 6500. We present a workflow for convenient PRM data processing using Skyline software which is free of charge. In this study we have established a reliable PRM methodology on a quadrupole-Orbitrap platform for evaluation of large-scale targeted metabolomics, which provides a new choice for basic and clinical metabolomics study.

  10. Validation of a LC/MS method for the determination of gemfibrozil in human plasma and its application to a pharmacokinetic study

    PubMed Central

    Rower, Joseph E.; Bushman, Lane R.; Hammond, Kyle P.; Kadam, Rajendra S.; Aquilante, Christina L.

    2011-01-01

    Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate, and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6% and 10.7%, and inter-assay precision ranging from 4.4% to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6% and 108.7% of the expected value, and inter-assay concentrations within 89.4 to 104.0% of the expected value. The linear concentration range was between 0.5 and 50 μg/mL with a lower limit of quantitation of 0.5 μg/mL when 125 μL of plasma were extracted. This LC/MS method yielded a quick, simple, and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. PMID:21077249

  11. Validation of an LC/MS method for the determination of gemfibrozil in human plasma and its application to a pharmacokinetic study.

    PubMed

    Rower, Joseph E; Bushman, Lane R; Hammond, Kyle P; Kadam, Rajendra S; Aquilante, Christina L

    2010-12-01

    Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6 and 10.7%, and inter-assay precision ranging from 4.4 to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6-108.7% of the expected value, and inter-assay concentrations within 89.4-104.0% of the expected value. The linear concentration range was between 0.5 and 50 µg/mL with a lower limit of quantitation of 0.5 µg/mL when 125 µL of plasma were extracted. This LC/MS method yielded a quick, simple and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.

  12. A monoclonal antibody based elisa for quantitation of human leukaemia inhibitory factor.

    PubMed

    Taupin, J L; Gualde, N; Moreau, J F

    1997-02-01

    The authors report on the development of a new sandwich enzyme-linked immunoabsorbent assay (ELISA) for the quantitation of the human cytokine leukaemia inhibitory factor/human interleukin for DA cells (LIF/HILDA) with high accuracy and sensitivity (23 pg/ml), in less than 5 h and in various biological fluids. The antibodies used in this assay were raised against recombinant glycosylated LIF expressed in vivo following inoculation of recombinant vaccinia viruses, and screened with the biologically active cytokine in a flow cytometry assay using cells expressing a membrane-bound form of LIF. Furthermore, this home-made assay was compared with two commercially available ELISA kits. The results led to the conclusion that these three assays are far from being equivalent between each other, in terms of sensitivity towards non-glycosylated vs glycosylated LIF. Two major parameters must be incriminated: the glycosylation status of the LIF molecule used as the calibrator, and the binding characteristics of the monoclonal antibodies used to set up these assays toward LIF derived from Escherichia coli or from eukaryotic cells. This points out the importance of these parameters for the design of ELISAs meant for the quantitation of glycosylated cytokines in biological fluids.

  13. Comparison of central HER2 testing with quantitative total HER2 expression and HER2 homodimer measurements using a novel proximity-based assay.

    PubMed

    Huang, Weidong; Reinholz, Monica; Weidler, Jodi; Yolanda, Lie; Paquet, Agnes; Whitcomb, Jeannette; Lingle, Wilma; Jenkins, Robert B; Chen, Beiyun; Larson, Jeffrey S; Tan, Yuping; Sherwood, Thomas; Bates, Michael; Perez, Edith A

    2010-08-01

    The accuracy and reliability of immunohistochemical analysis and in situ hybridization for the assessment of HER2 status remains a subject of debate. We developed a novel assay (HERmark Breast Cancer Assay, Monogram Biosciences, South San Francisco, CA) that provides precise quantification of total HER2 protein expression (H2T) and HER2 homodimers (H2D) in formalin-fixed, paraffin-embedded tissue specimens. H2T and H2D results of 237 breast cancers were compared with those of immunohistochemical studies and fluorescence in situ hybridization (FISH) centrally performed at the Mayo Clinic, Rochester, MN. H2T described a continuum across a wide dynamic range ( approximately 2.5 log). Excluding the equivocal cases, HERmark showed 98% concordance with immunohistochemical studies for positive and negative assay values. For the 94 immunohistochemically equivocal cases, 67% and 39% concordance values were observed between HERmark and FISH for positive and negative assay values, respectively. Polysomy 17 in the absence of HER2 gene amplification did not result in HER2 overexpression as evaluated quantitatively using the HERmark assay.

  14. B220 analysis with the local lymph node assay: proposal for a more flexible prediction model.

    PubMed

    Betts, Catherine J; Dearman, Rebecca J; Kimber, Ian; Ryan, Cindy A; Gerberick, G Frank; Lalko, Jon; Api, Anne Marie

    2007-01-01

    The mouse local lymph node assay (LLNA) has been developed and validated for the identification of chemicals that have the potential to induce skin sensitisation. In common with other predictive test methods the accuracy of the LLNA is not absolute and experience has revealed that a few chemicals, including for instance a minority of skin irritants, may elicit false-positive reactions in the assay. To improve further the performance of the LLNA, and to eliminate or reduce false-positives, there has been interest in an adjunct method in which the ability of chemicals to cause increases in the frequency of B220(+) lymphocytes in skin-draining lymph nodes is measured. Previous studies suggest that the use of B220 analyses aligned with the standard LLNA may serve to distinguish further between contact allergens and skin irritants. In the original predictive model, chemicals were regarded as being skin sensitisers if they were able to induce a 1.25-fold or greater increase in the percentage of B220(+) cells within lymph nodes compared with concurrent vehicle controls. Although this first prediction model has proven useful, in the light of more recent experience, and specifically as a consequence of some variability observed in the frequency of B220(+) lymphocytes in nodes taken from vehicle control-treated animals, it is timely now to reconsider and refine the model. As a result a new prediction model is proposed in which reliance on the use of absolute thresholds is reduced, and in which small changes in control values can be better accommodated. (c) 2007 John Wiley & Sons, Ltd.

  15. Quantitative and multiplexed detection for blood typing based on quantum dot-magnetic bead assay.

    PubMed

    Xu, Ting; Zhang, Qiang; Fan, Ya-Han; Li, Ru-Qing; Lu, Hua; Zhao, Shu-Ming; Jiang, Tian-Lun

    2017-01-01

    Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads. In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples. Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 10 5 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively. In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety.

  16. Polymerase chain reaction in the detection of tumor cells: new approaches in diagnosis and follow-up of patients with thyroid cancer.

    PubMed

    Bojunga, Jörg; Kusterer, Klaus; Schumm-Draeger, Petra-Maria; Usadel, Klaus-Henning

    2002-12-01

    Thyroid cancers are the most common endocrine malignancies and are being diagnosed with increasing frequency. In addition to other measures, diagnosis is based on fine-needle aspiration cytology examination. Recently, new assays using reverse transcription-polymerase chain reaction (PCR) are being tested to improve sensitivity and specificity of primary diagnosis and detection of recurrent thyroid cancer. In the preoperative diagnosis of thyroid cancer, several tissue- and/or tumor-specific mRNA have been described and in several cases, a higher sensitivity and specificity could be achieved using molecular techniques compared to conventional methods. In the postoperative follow-up of patients with thyroid cancer, conflicting data have been published and the use of PCR techniques revealed several problems of the molecular approach, which are based on some technical as well as biologic limitations. Despite these problems, which are discussed in detail in this review, molecular techniques may nevertheless improve the sensitivity and accuracy of fine-needle aspiration of thyroid nodules, fine-needle aspiration of metastases, and detection of recurrent disease in peripheral blood samples.

  17. Benefits and challenges of molecular diagnostics for childhood tuberculosis.

    PubMed

    Gutierrez, Cristina

    2016-12-01

    Expanding tuberculosis (TB)-diagnostic services, including access to rapid tests, is a World Health Organization (WHO) strategy to accelerate progress toward ending TB. Faster and more sensitive molecular tests capable of diagnosing TB and drug-resistant TB have the technical capacity to address limitations associated with smears and cultures by increasing accuracy and shortening turnaround times as compared with those of these conventional laboratory methods. Nucleic acid amplification assays used to detect and analyze Mycobacterium tuberculosis (MTB)-complex nucleic acids can be used directly on specimens from patients suspected of having TB. Recently, several commercial molecular tests were developed to detect MTB and determine the drug resistance (DR) based on detection of specific genetic mutations conferring resistance. The first to be endorsed by the WHO was molecular line-probe assay technology. This test uses polymerase chain reaction (PCR) and reverse-hybridization methods to rapidly identify MTB and DR-related mutations simultaneously. More recently, the WHO endorsed Xpert MTB/RIF, Cepheid Inc, CA, USA, a fully automated assay used for TB diagnosis that relies upon PCR techniques for detection of TB and rifampicin resistance-related mutations. Other promising molecular TB assays for simplifying PCR-based testing protocols and increasing their accuracy are under development and evaluation. Although we lack a practical gold standard for the diagnosis of childhood TB, its bacteriological confirmation is always recommended to be sought whenever possible prior to a diagnostic decision being made. Conventional diagnostic laboratory TB tests are less efficient for children as compared with adults, because sufficient sputum samples are more difficult to collect from infants and young children, and their disease is often paucibacillary, resulting in smear-negative disease. These inherent challenges associated with childhood TB are due to immunological- and pathophysiological-response differences relative to those observed in adults. Several recent meta-analyses showed low sensitivity estimates of PCR-based TB assays for paucibacillary forms of TB (extrapulmonary TB and smear-negative pulmonary disease), which represent the vast majority of childhood TB cases. Despite the lack of evidence regarding use of the rapid molecular assays to identify TB and detect DR in children, and due to the clinical nature of childhood TB, TB-expert groups recommend including rapid methods for TB identification and DR detection in diagnostic algorithms for children suspected of both smear-positive and -negative pulmonary or extrapulmonary TB, both with or without human immunodeficiency virus (HIV)-coinfection, when combined with standard methods (including clinical, microbiological, and radiological assessment) for diagnosing active TB and conventional DR. Since 2011, the WHO has specifically recommended use of the Xpert MTB/RIF test as an initial diagnostic tool for children with suspected HIV-associated TB or multidrug-resistant TB based on successful treatment data related to adults. Implementation of the rapid molecular assays for rapid detection of TB and DR should occur in laboratories with proven capability to run molecular tests and where quality control systems are implemented. Molecular approaches should be more largely tested in children, given their status as the group in whom the diagnostic dilemma is most pronounced. These tests should also be included in specific childhood TB diagnostic algorithms adapted to the local/national context in combination with other strategies for improving diagnostics, including more effective specimen collection. Copyright © 2016.

  18. Development and evaluation of flow through assay for detection of antibodies against porcine cysticercosis.

    PubMed

    Sreedevi, C; Hafeez, Md; Subramanyam, K V; Anand Kumar, P; Chengalva Rayulu, V

    2011-04-01

    A flow through assay (FTA) was developed on cellulose acetate membrane for the serodiagnosis of porcine cysticercosis using cyst fluid (CFA) and whole cyst antigens (WCA) of Taenia solium metacestode. The assay consisted of antigen of T. solium metacestode coated onto membrane, mounted on a flow-through test device to provide assay capture matrix. The optimum concentration of coating antigen was 250 ng. The protein A colloidal gold conjugate served as antigen-antibody detecting reagent. A total of 225 serum samples were tested using two antigens. Results were better with CFA (96.0% sensitivity; 96.0% specificity) compared to WCA (92.0% sensitivity; 96.0% specificity). The test was also compared with enzyme-linked immunosorbent assay. The ELISA showed 96 per cent sensitivity with both the antigens whereas; the specificity was 96 and 92 per cent with CFA and WCA respectively. The sensitivity and specificity of flow through assay agrees closely with those of the ELISA. The cross-reaction was observed in one out of eight hydatidosis positive pigs (12.5%) with CFA by both the assays. The highest diagnostic accuracy (96%) was obtained with CFA-FTA and CFA-ELISA. For its high sensitivity and sporadic cross-reactions, CFA-FTA appears to be suitable for practical use at field level without instrumentation.

  19. [Evaluation of serum PIVKA-II by Lumipulse PrestoII assay].

    PubMed

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Kani, Satomi; Goto, Takaaki; Takasaka, Yoshimitsu; Matsuura, Kentaro; Sugauchi, Fuminaka; Moriyama, Kazushige; Murakami, Hiroshi; Kitajima, Sachiko; Mizokami, Masashi

    2009-03-01

    Measurements of serum concentrations of Des-gamma-carboxy Prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, in Lumipulsef assay, it was reported that antibodies against alkaline phosphatase (ALP) derived from anti bleeding sheets led false high values of PIVKA-II in the patients with HCC resection. To improve the previous issue, newly developed Lumipulse PrestoII assay was examined. (1) The assay was reliable and positively correlated with the previous assays (Lumipulse f and Picolumi, R = 0.997 and 0.994 (n=115), respectively). (2) Eleven cases, which had false high values of PIVKA-II by the Lumipulsef assay, were examined by the PrestoII assay with excess of inactive ALP. The false high values of 10 cases were improved, but only one was still high. False reactivity of this case was stronger than other cases, more effective adsorption was required. (3) Comparing the absorbent activity of inactive ALP among 6 different kinds, we found inactive ALP with much higher adsorbent activity. When this inactive ALP was applied to assay, false high values of PIVKA-II were improved in all 11 cases. In conclusion, the PrestoII assay, which applies the inactive ALP with high activity, is reliable and useful for clinical screening.

  20. Impact of assay design on test performance: lessons learned from 25-hydroxyvitamin D.

    PubMed

    Farrell, Christopher-John L; Soldo, Joshua; McWhinney, Brett; Bandodkar, Sushil; Herrmann, Markus

    2014-11-01

    Current automated immunoassays vary significantly in many aspects of their design. This study sought to establish if the theoretical advantages and disadvantages associated with different design formats of automated 25-hydroxyvitamin D (25-OHD) assays are translated into variations in assay performance in practice. 25-OHD was measured in 1236 samples using automated assays from Abbott, DiaSorin, Roche and Siemens. A subset of 362 samples had up to three liquid chromatography-tandem mass spectrometry 25-OHD analyses performed. 25-OHD₂ recovery, dilution recovery, human anti-animal antibody (HAAA) interference, 3-epi-25-OHD₃ cross-reactivity and precision of the automated assays were evaluated. The assay that combined release of 25-OHD with analyte capture in a single step showed the most accurate 25-OHD₂ recovery and the best dilution recovery. The use of vitamin D binding protein (DBP) as the capture moiety was associated with 25-OHD₂ under-recovery, a trend consistent with 3-epi-25-OHD₃ cross-reactivity and immunity to HAAA interference. Assays using animal-derived antibodies did not show 3-epi-25-OHD₃ cross-reactivity but were variably susceptible to HAAA interference. Not combining 25-OHD release and capture in one step and use of biotin-streptavidin interaction for solid phase separation were features of the assays with inferior accuracy for diluted samples. The assays that used a backfill assay format showed the best precision at high concentrations but this design did not guarantee precision at low 25-OHD concentrations. Variations in design among automated 25-OHD assays influence their performance characteristics. Consideration of the details of assay design is therefore important when selecting and validating new assays.

  1. Continuous Glucose Monitoring in Subjects with Type 1 Diabetes: Improvement in Accuracy by Correcting for Background Current

    PubMed Central

    Youssef, Joseph El; Engle, Julia M.; Massoud, Ryan G.; Ward, W. Kenneth

    2010-01-01

    Abstract Background A cause of suboptimal accuracy in amperometric glucose sensors is the presence of a background current (current produced in the absence of glucose) that is not accounted for. We hypothesized that a mathematical correction for the estimated background current of a commercially available sensor would lead to greater accuracy compared to a situation in which we assumed the background current to be zero. We also tested whether increasing the frequency of sensor calibration would improve sensor accuracy. Methods This report includes analysis of 20 sensor datasets from seven human subjects with type 1 diabetes. Data were divided into a training set for algorithm development and a validation set on which the algorithm was tested. A range of potential background currents was tested. Results Use of the background current correction of 4 nA led to a substantial improvement in accuracy (improvement of absolute relative difference or absolute difference of 3.5–5.5 units). An increase in calibration frequency led to a modest accuracy improvement, with an optimum at every 4 h. Conclusions Compared to no correction, a correction for the estimated background current of a commercially available glucose sensor led to greater accuracy and better detection of hypoglycemia and hyperglycemia. The accuracy-optimizing scheme presented here can be implemented in real time. PMID:20879968

  2. Improving critical thinking and clinical reasoning with a continuing education course.

    PubMed

    Cruz, Dina Monteiro; Pimenta, Cibele Mattos; Lunney, Margaret

    2009-03-01

    Continuing education courses related to critical thinking and clinical reasoning are needed to improve the accuracy of diagnosis. This study evaluated a 4-day, 16-hour continuing education course conducted in Brazil.Thirty-nine nurses completed a pretest and a posttest consisting of two written case studies designed to measure the accuracy of nurses' diagnoses. There were significant differences in accuracy from pretest to posttest for case 1 (p = .008) and case 2 (p = .042) and overall (p = .001). Continuing education courses should be implemented to improve the accuracy of nurses' diagnoses.

  3. Computational Modeling and Simulation of Developmental Toxicity. What can we learn from a virtual embryo? (FDA-CFSAN workshop)

    EPA Science Inventory

    SYNOPSIS: The question of how tissues and organs are shaped during development is crucial for understanding human birth defects. Data from high-throughput screening assays on human stem cells may be utilized predict developmental toxicity with reasonable accuracy. Other types of ...

  4. Fluorescein Diacetate Microplate Assay in Cell Viability Detection.

    PubMed

    Chen, Xi; Yang, Xiu-Ying; Fang, Lian-Hua; DU, Guan-Hua

    2016-12-20

    Objective To investigate the application of the fluorescein diacetate (FDA) microplate assay in cell viability detection. Methods Cells were seeded in a 96-well culture plate until detection. After incubated with FDA,the plate was detected by fluorescence microplate analyzer. The effects of FDA incubation duration,concentration,and other factors on the assay's accuracy and stability were assessed. We also compared the results of FDA with methyl thiazolyl(MTT) in terms of cell numbers and H 2 O 2 injury. Results Within 0-30 minutes,the fluorescence-cell number coefficient of FDA assay increased with duration and reached 0.99 in 27-30 minutes. The optimum concentration of final FDA in this study was 10-30 μg/ml. On cell viability detection,the result of FDA method was equivalent to MTT method. As to H 2 O 2 injury assay,the sensitivity of FDA method was superior to MTT on the higher concentration H 2 O 2 treatment due to a relative shorter duration for detection. Conclusion As a stable and reliable method,FDA is feasible for cell variability detection under varied conditions.

  5. Rapid and direct spectrophotometric method for kinetics studies and routine assay of peroxidase based on aniline diazo substrates.

    PubMed

    Mirazizi, Fatemeh; Bahrami, Azita; Haghbeen, Kamahldin; Shahbani Zahiri, Hossein; Bakavoli, Mehdi; Legge, Raymond L

    2016-12-01

    Peroxidases are ubiquitous enzymes that play an important role in living organisms. Current spectrophotometrically based peroxidase assay methods are based on the production of chromophoric substances at the end of the enzymatic reaction. The ambiguity regarding the formation and identity of the final chromophoric product and its possible reactions with other molecules have raised concerns about the accuracy of these methods. This can be of serious concern in inhibition studies. A novel spectrophotometric assay for peroxidase, based on direct measurement of a soluble aniline diazo substrate, is introduced. In addition to the routine assays, this method can be used in comprehensive kinetics studies. 4-[(4-Sulfophenyl)azo]aniline (λmax = 390 nm, ɛ = 32 880 M(-1) cm(-1) at pH 4.5 to 9) was introduced for routine assay of peroxidase. This compound is commercially available and is indexed as a food dye. Using this method, a detection limit of 0.05 nmol mL(-1) was achieved for peroxidase.

  6. Prediction of Skin Sensitization with a Particle Swarm Optimized Support Vector Machine

    PubMed Central

    Yuan, Hua; Huang, Jianping; Cao, Chenzhong

    2009-01-01

    Skin sensitization is the most commonly reported occupational illness, causing much suffering to a wide range of people. Identification and labeling of environmental allergens is urgently required to protect people from skin sensitization. The guinea pig maximization test (GPMT) and murine local lymph node assay (LLNA) are the two most important in vivo models for identification of skin sensitizers. In order to reduce the number of animal tests, quantitative structure-activity relationships (QSARs) are strongly encouraged in the assessment of skin sensitization of chemicals. This paper has investigated the skin sensitization potential of 162 compounds with LLNA results and 92 compounds with GPMT results using a support vector machine. A particle swarm optimization algorithm was implemented for feature selection from a large number of molecular descriptors calculated by Dragon. For the LLNA data set, the classification accuracies are 95.37% and 88.89% for the training and the test sets, respectively. For the GPMT data set, the classification accuracies are 91.80% and 90.32% for the training and the test sets, respectively. The classification performances were greatly improved compared to those reported in the literature, indicating that the support vector machine optimized by particle swarm in this paper is competent for the identification of skin sensitizers. PMID:19742136

  7. How to diagnose food allergy.

    PubMed

    Sato, Sakura; Yanagida, Noriyuki; Ebisawa, Motohiro

    2018-06-01

    To assess the recent studies that focus on specific immunoglobulin E (sIgE) testing and basophil activation test (BAT) for diagnosing IgE-mediated food allergies. The sIgE to allergen extract or component can predict reactivity to food. The cutoff value based on the positive predictive value (PPV) of sIgE can be considered whenever deciding whether oral food challenge (OFC) is required to diagnose hen's egg, cow's milk, wheat, peanut, and cashew nut allergy. However, PPV varies depending on the patients' background, OFC methodology, challenge foods, and assay methodology. Component-resolved diagnostics (CRD) has been used for food allergy diagnosis. Ovomucoid and omega-5 gliadin are good diagnostic markers for heated egg and wheat allergy. More recently, CRD of peanut, tree nuts, and seed have been investigated. Ara h 2 showed the best diagnostic accuracy for peanut allergy; other storage proteins, such as Jug r 1 for walnut, Ana o 3 for cashew nut, Ses i 1 for sesame, and Fag e 3 for buckwheat, are also better markers than allergen extracts. Some studies suggested that BAT has superior specificity than skin prick test and sIgE testing. The sIgE testing and BAT can improve diagnostic accuracy. CRD provides additional information that can help determine whether OFCs should be performed to diagnose food allergy.

  8. Plant pathogen nanodiagnostic techniques: forthcoming changes?

    PubMed Central

    Khiyami, Mohammad A.; Almoammar, Hassan; Awad, Yasser M.; Alghuthaymi, Mousa A.; Abd-Elsalam, Kamel A.

    2014-01-01

    Plant diseases are among the major factors limiting crop productivity. A first step towards managing a plant disease under greenhouse and field conditions is to correctly identify the pathogen. Current technologies, such as quantitative polymerase chain reaction (Q-PCR), require a relatively large amount of target tissue and rely on multiple assays to accurately identify distinct plant pathogens. The common disadvantage of the traditional diagnostic methods is that they are time consuming and lack high sensitivity. Consequently, developing low-cost methods to improve the accuracy and rapidity of plant pathogens diagnosis is needed. Nanotechnology, nano particles and quantum dots (QDs) have emerged as essential tools for fast detection of a particular biological marker with extreme accuracy. Biosensor, QDs, nanostructured platforms, nanoimaging and nanopore DNA sequencing tools have the potential to raise sensitivity, specificity and speed of the pathogen detection, facilitate high-throughput analysis, and to be used for high-quality monitoring and crop protection. Furthermore, nanodiagnostic kit equipment can easily and quickly detect potential serious plant pathogens, allowing experts to help farmers in the prevention of epidemic diseases. The current review deals with the application of nanotechnology for quicker, more cost-effective and precise diagnostic procedures of plant diseases. Such an accurate technology may help to design a proper integrated disease management system which may modify crop environments to adversely affect crop pathogens. PMID:26740775

  9. Accurate Detection of Streptococcus pyogenes at the Point of Care Using the cobas Liat Strep A Nucleic Acid Test.

    PubMed

    Wang, Fangnian; Tian, Yu; Chen, Lingjun; Luo, Robert; Sickler, Joanna; Liesenfeld, Oliver; Chen, Shuqi

    2017-10-01

    The performance of a polymerase chain reaction-based point-of-care assay, the cobas Strep A Nucleic Acid Test for use on the cobas Liat System (cobas Liat Strep A assay), for the detection of group A Streptococcus bacteria was evaluated in primary care settings. Throat swab specimens from 427 patients were tested with the cobas Liat Strep A assay and a rapid antigen detection test (RADT) by existing medical staff at 5 primary care clinics, and results were compared with bacterial culture. The cobas Liat Strep A assay demonstrated equivalent sensitivity (97.7%) and specificity (93.3%) to reference culture with a 15-minute turnaround time. In comparison to RADTs, the cobas Liat Strep A assay showed improved sensitivity (97.7% Liat vs 84.5% RADT). The Clinical Laboratory Improvement Amendments-waived cobas Liat Strep A assay demonstrated the ease of use and improved turnaround time of RADTs along with the sensitivity of culture.

  10. A simple and highly repeatable viral plaque assay for enterovirus 71.

    PubMed

    Yin, Yingxian; Xu, Yi; Ou, Zhiying; Su, Ling; Xia, Huimin

    2015-04-01

    The classic plaque assay is a method for counting infectious viral particles, however its complexity limits its use in a variety of virological experiments. To simplify the operation and to improve the repeatability, we employed an improved plaque assay procedure based on Avicel to make the whole experiment easier and optimize the results on a model of Vero cells infection with Enterovirus 71(EV71). Clear plaques visible to the naked eyes can be formed on a 24-well plate or a 96-well plate without immunostaining. Following further improvement, this plaque assay procedure could be applied to other viruses, being both simple and repeatable. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Performance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method.

    PubMed

    Ahn, Ilyoung; Kim, Tae-Sung; Jung, Eun-Sun; Yi, Jung-Sun; Jang, Won-Hee; Jung, Kyoung-Mi; Park, Miyoung; Jung, Mi-Sook; Jeon, Eun-Young; Yeo, Kyeong-Uk; Jo, Ji-Hoon; Park, Jung-Eun; Kim, Chang-Yul; Park, Yeong-Chul; Seong, Won-Keun; Lee, Ai-Young; Chun, Young Jin; Jeong, Tae Cheon; Jeung, Eui Bae; Lim, Kyung-Min; Bae, SeungJin; Sohn, Soojung; Heo, Yong

    2016-10-01

    Local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple endpoints with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Combined quantification of paclitaxel, docetaxel and ritonavir in human feces and urine using LC-MS/MS.

    PubMed

    Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2014-02-01

    A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Discrimination of skin sensitizers from non-sensitizers by interleukin-1α and interleukin-6 production on cultured human keratinocytes.

    PubMed

    Jung, Daun; Che, Jeong-Hwan; Lim, Kyung-Min; Chun, Young-Jin; Heo, Yong; Seok, Seung Hyeok

    2016-09-01

    In vitro testing methods for classifying sensitizers could be valuable alternatives to in vivo sensitization testing using animal models, such as the murine local lymph node assay (LLNA) and the guinea pig maximization test (GMT), but there remains a need for in vitro methods that are more accurate and simpler to distinguish skin sensitizers from non-sensitizers. Thus, the aim of our study was to establish an in vitro assay as a screening tool for detecting skin sensitizers using the human keratinocyte cell line, HaCaT. HaCaT cells were exposed to 16 relevant skin sensitizers and 6 skin non-sensitizers. The highest dose used was the dose causing 75% cell viability (CV75) that we determined by an MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay. The levels of extracellular production of interleukin-1α (IL-1α) and IL-6 were measured. The sensitivity of IL-1α was 63%, specificity was 83% and accuracy was 68%. In the case of IL-6, sensitivity: 69%, specificity: 83% and accuracy: 73%. Thus, this study suggests that measuring extracellular production of pro-inflammatory cytokines IL-1α and IL-6 by human HaCaT cells may potentially classify skin sensitizers from non-sensitizers. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Target-induced proximity ligation triggers recombinase polymerase amplification and transcription-mediated amplification to detect tumor-derived exosomes in nasopharyngeal carcinoma with high sensitivity.

    PubMed

    Liu, Wanli; Li, Jianpei; Wu, Yixian; Xing, Shan; Lai, Yanzhen; Zhang, Ge

    2018-04-15

    Tumor-derived exosomes (TEXs) are extracellular vesicles that are continuously released into the blood by tumor cells and carry specific surface markers of the original tumor cells. Substantial evidence has implicated TEXs as attractive diagnostic markers for cancer. However, the detection of TEXs in blood at an early tumor stage is challenging due to their very low concentration. Here, we established a method called PLA-RPA-TMA assay that allows TEXs to be detected with high sensitivity and specificity. Based on two proximity ligation assay (PLA) probes that recognize a biomarker on a TEX, we generated a unique surrogate DNA signal for the specific biomarker, which was synchronously amplified twice by recombinase polymerase amplification (RPA) coupled with transcription-mediated amplification (TMA), and then the products of the RPA-TMA reaction were quantitatively detected using a gold nanoparticle-based colorimetric assay. We established proof-of-concept evidence for this approach using TEXs from nasopharyngeal carcinoma (NPC) cells, with a detection limit of 10 2 particles/mL, and reported the measurement of plasma Epstein-Barr virus latent membrane protein 1 (LPM1)-positive (LMP1 + , accuracy: 0.956) and epidermal growth factor receptor (EGFR)-positive (EGFR + , accuracy: 0.906) TEXs as potent early diagnostic biomarkers for NPC. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Detection and identification of intestinal pathogenic bacteria by hybridization to oligonucleotide microarrays

    PubMed Central

    Jin, Lian-Qun; Li, Jun-Wen; Wang, Sheng-Qi; Chao, Fu-Huan; Wang, Xin-Wei; Yuan, Zheng-Quan

    2005-01-01

    AIM: To detect the common intestinal pathogenic bacteria quickly and accurately. METHODS: A rapid (<3 h) experimental procedure was set up based upon the gene chip technology. Target genes were amplified and hybridized by oligonucleotide microarrays. RESULTS: One hundred and seventy strains of bacteria in pure culture belonging to 11 genera were successfully discriminated under comparatively same conditions, and a series of specific hybridization maps corresponding to each kind of bacteria were obtained. When this method was applied to 26 divided cultures, 25 (96.2%) were identified. CONCLUSION: Salmonella sp., Escherichia coli, Shigella sp., Listeria monocytogenes, Vibrio parahaemolyticus, Staphylococcus aureus, Proteus sp., Bacillus cereus, Vibrio cholerae, Enterococcus faecalis, Yersinia enterocolitica, and Campylobacter jejuni can be detected and identified by our microarrays. The accuracy, range, and discrimination power of this assay can be continually improved by adding further oligonucleotides to the arrays without any significant increase of complexity or cost. PMID:16437687

  16. The role of flow cytometry in companion animal diagnostic medicine.

    PubMed

    Tarrant, Jacqueline M

    2005-11-01

    Flow cytometry is a powerful tool for characterising the composition of complex cell populations. The accuracy and precision of this technology for describing and enumerating cells exceeds traditional methods. The number of diagnostic veterinary laboratories with access to a dedicated machine is increasing, and there is the potential to offer a clinical flow cytometry service. The improved availability of monoclonal antibodies (mAb) to cell markers expressed by the leukocytes of companion animals, permits the implementation of comprehensive mAb panels suitable for diagnosis of lympho- and myeloproliferative disease. Reticulated erythrocyte and platelet quantification, antiglobulin assays for immune-mediated cytopenias, lymphocyte subset analysis, and immunophenotyping of lymphoma and leukemia, have been validated for companion animal samples on the flow cytometer. It is now timely to consider the role of flow cytometry in diagnostic practice, and the requirement for quality assurance and standardization of testing procedures.

  17. High-content screening in microfluidic devices.

    PubMed

    Cheong, Raymond; Paliwal, Saurabh; Levchenko, Andre

    2010-08-01

    Miniaturization is the key to advancing the state of the art in high-content screening (HCS) in order to enable dramatic cost savings through reduced usage of expensive biochemical reagents and to enable large-scale screening on primary cells. Microfluidic technology offers the potential to enable HCS to be performed with an unprecedented degree of miniaturization. This perspective highlights a real-world example from the authors’ work of HCS assays implemented in a highly miniaturized microfluidic format. The advantages of this technology are discussed, including cost savings, high-throughput screening on primary cells, improved accuracy, the ability to study complex time-varying stimuli, and ease of automation, integration and scaling. The reader will understand the capabilities of anew microfluidics-based platform for HCS and the advantages it provides over conventional plate-based HCS. Microfluidics technology will drive significant advancements and broader usage and applicability of HCS in drug discovery.

  18. Multiplexing T- and B-Cell FLUOROSPOT Assays: Experimental Validation of the Multi-Color ImmunoSpot® Software Based on Center of Mass Distance Algorithm.

    PubMed

    Karulin, Alexey Y; Megyesi, Zoltán; Caspell, Richard; Hanson, Jodi; Lehmann, Paul V

    2018-01-01

    Over the past decade, ELISPOT has become a highly implemented mainstream assay in immunological research, immune monitoring, and vaccine development. Unique single cell resolution along with high throughput potential sets ELISPOT apart from flow cytometry, ELISA, microarray- and bead-based multiplex assays. The necessity to unambiguously identify individual T and B cells that do, or do not co-express certain analytes, including polyfunctional cytokine producing T cells has stimulated the development of multi-color ELISPOT assays. The success of these assays has also been driven by limited sample/cell availability and resource constraints with reagents and labor. There are few commercially available test kits and instruments available at present for multi-color FLUOROSPOT. Beyond commercial descriptions of competing systems, little is known about their accuracy in experimental settings detecting individual cells that secrete multiple analytes vs. random overlays of spots. Here, we present a theoretical and experimental validation study for three and four color T- and B-cell FLUOROSPOT data analysis. The ImmunoSpot ® Fluoro-X™ analysis system we used includes an automatic image acquisition unit that generates individual color images free of spectral overlaps and multi-color spot counting software based on the maximal allowed distance between centers of spots of different colors or Center of Mass Distance (COMD). Using four color B-cell FLUOROSPOT for IgM, IgA, IgG1, IgG3; and three/four color T-cell FLUOROSPOT for IL-2, IFN-γ, TNF-α, and GzB, in serial dilution experiments, we demonstrate the validity and accuracy of Fluoro-X™ multi-color spot counting algorithms. Statistical predictions based on the Poisson spatial distribution, coupled with scrambled image counting, permit objective correction of true multi-color spot counts to exclude randomly overlaid spots.

  19. Prospective evaluation of NT-proBNP assay to detect occult dilated cardiomyopathy and predict survival in Doberman Pinschers.

    PubMed

    Singletary, G E; Morris, N A; Lynne O'Sullivan, M; Gordon, S G; Oyama, M A

    2012-01-01

    Occult (asymptomatic) dilated cardiomyopathy (ODCM) is highly prevalent in Doberman Pinschers. Assess ability of NT-proBNP assay to detect ODCM and predict death. 155 asymptomatic Dobermans presenting for ODCM screening. Echocardiography, 24-hour Holter, and NT-proBNP assay were performed prospectively. Diagnosis was based on increased left ventricular end-systolic dimension, >50 ventricular premature complexes (VPCs), or both on Holter. Utility was evaluated using receiver-operating characteristic curves. Effect of age, weight, sex, disease status, VPCs, and NT-proBNP on survival was analyzed using Kaplan-Meier and Cox-proportional hazard analysis. Seventy-three (47.1%) Dobermans were diagnosed with ODCM, including 31, 17, and 25 that met Holter, echocardiographic, or both criteria, respectively. Sensitivity of NT-proBNP > 457 pmol/L to detect these groups was 45.2, 76.5, and 96.0%, respectively. Combination of NT-proBNP and Holter to detect ODCM yielded sensitivity of 94.5%, specificity of 87.8%, and accuracy of 91.0%. Follow-up data were available for 78 Dobermans. The median survival time of Dobermans with > 50 VPCs (469 days), NT-proBNP > 900 pmol/L (284 days), or ODCM (474 days) was significantly (P < .0001) shorter than those with < 50 VPCs (1743 days), NT-proBNP < 900 pmol/L (1743 days), or without disease (1743 days). NT-proBNP concentration and disease status were independently predictive of all-cause mortality. The combination of NT-proBNP assay and Holter detected ODCM with high accuracy. NT-proBNP and disease status were independently associated with survival. NT-proBNP assay identified Dobermans with high probability of increased LVIDs consistent with ODCM, and can facilitate pursuit of confirmatory diagnostic testing, such as echocardiography, in suspected Dobermans. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  20. Development and validation of a high-throughput stereoselective LC-MS/MS assay for bupropion, hydroxybupropion, erythrohydrobupropion, and threohydrobupropion in human plasma

    PubMed Central

    Teitelbaum, Aaron M.; Flaker, Alicia M.; Kharasch, Evan D.

    2016-01-01

    A stereoselective analytical method was developed and validated for the quantification of bupropion, and principle metabolites hydroxybupropion, erythrohydrobupropion and threohydrobupropion in human plasma. Separation of individual enantiomers (R)-bupropion, (S)-bupropion, (R,R)-hydroxybupropion, (S,S-hydroxybupropion), (1S,2S)-threohydrobupropion, (1R,2R)-threohydrobupropion, (1R,2S)-erythrohydrobupropion, and (1S,2R)-erythrohydrobupropion was achieved utilizing an α1-acid glycoprotein column within a 12-minute run time. Chromatograph separation was significantly influenced by mobile phase pH and variability between columns. Analytes were quantified by positive ion electrospray tandem mass spectrometry following plasma protein precipitation with 20% trichloroacetic acid. Identification of erythrohydrobupropion enantiomer peaks and threohydrobupropion enantiomer peaks was achieved by sodium borohydride reduction of enantiopure (R)- and (S)-bupropion. Initial assay validation and sensitivity determination was on AB Sciex 3200, 4000 QTRAP, and 6500 mass spectrometers. Accuracy and precision were within 15% for each analyte. The assay was fully validated over analyte-specific concentrations using an AB Sciex 3200 mass spectrometer. Intra- and inter-assay precision and accuracy were within 12% for each analyte. The limits of quantification for bupropion (R and S), hydroxybupropion (R,R and S,S), threohydrobupropion (1S,2S and 1R,2R), and erythrohydrobupropion (1R,2S and 1S,2R) were 0.5, 2, 1, and 1 ng/mL, respectively. All analytes were stable following freeze thaw cycles at −80°C and while stored at 4°C in the instrument autosampler. This method was applicable to clinical pharmacokinetic investigations of bupropion in patients. This is the first chromatographic method to resolve erythrohydrobupropion and threohydrobupropion enantiomers, and the first stereoselective LC-MS/MS assay to quantify bupropion, and principle metabolites hydroxybupropion, erythrohydrobupropion, and threohydrobupropion in human plasma. PMID:26963497

  1. Pediatric Disaster Triage: Multiple Simulation Curriculum Improves Prehospital Care Providers' Assessment Skills.

    PubMed

    Cicero, Mark Xavier; Whitfill, Travis; Overly, Frank; Baird, Janette; Walsh, Barbara; Yarzebski, Jorge; Riera, Antonio; Adelgais, Kathleen; Meckler, Garth D; Baum, Carl; Cone, David Christopher; Auerbach, Marc

    2017-01-01

    Paramedics and emergency medical technicians (EMTs) triage pediatric disaster victims infrequently. The objective of this study was to measure the effect of a multiple-patient, multiple-simulation curriculum on accuracy of pediatric disaster triage (PDT). Paramedics, paramedic students, and EMTs from three sites were enrolled. Triage accuracy was measured three times (Time 0, Time 1 [two weeks later], and Time 2 [6 months later]) during a disaster simulation, in which high and low fidelity manikins and actors portrayed 10 victims. Accuracy was determined by participant triage decision concordance with predetermined expected triage level (RED [Immediate], YELLOW [Delayed], GREEN [Ambulatory], BLACK [Deceased]) for each victim. Between Time 0 and Time 1, participants completed an interactive online module, and after each simulation there was an individual debriefing. Associations between participant level of training, years of experience, and enrollment site were determined, as were instances of the most dangerous mistriage, when RED and YELLOW victims were triaged BLACK. The study enrolled 331 participants, and the analysis included 261 (78.9%) participants who completed the study, 123 from the Connecticut site, 83 from Rhode Island, and 55 from Massachusetts. Triage accuracy improved significantly from Time 0 to Time 1, after the educational interventions (first simulation with debriefing, and an interactive online module), with a median 10% overall improvement (p < 0.001). Subgroup analyses showed between Time 0 and Time 1, paramedics and paramedic students improved more than EMTs (p = 0.002). Analysis of triage accuracy showed greatest improvement in overall accuracy for YELLOW triage patients (Time 0 50% accurate, Time1 100%), followed by RED patients (Time 0 80%, Time 1 100%). There was no significant difference in accuracy between Time 1 and Time 2 (p = 0.073). This study shows that the multiple-victim, multiple-simulation curriculum yields a durable 10% improvement in simulated triage accuracy. Future iterations of the curriculum can target greater improvements in EMT triage accuracy.

  2. Prospective validation of a novel renal activity index of lupus nephritis.

    PubMed

    Gulati, G; Bennett, M R; Abulaban, K; Song, H; Zhang, X; Ma, Q; Brodsky, S V; Nadasdy, T; Haffner, C; Wiley, K; Ardoin, S P; Devarajan, P; Ying, J; Rovin, B H; Brunner, H I

    2017-08-01

    Objectives The renal activity index for lupus (RAIL) score was developed in children with lupus nephritis as a weighted sum of six urine biomarkers (UBMs) (neutrophil gelatinase-associated lipocalin, monocyte chemotactic protein 1, ceruloplasmin, adiponectin, hemopexin and kidney injury molecule 1) measured in a random urine sample. We aimed at prospectively validating the RAIL in adults with lupus nephritis. Methods Urine from 79 adults was collected at the time of kidney biopsy to assay the RAIL UBMs. Using receiver operating characteristic curve analysis, we evaluated the accuracy of the RAIL to discriminate high lupus nephritis activity status (National Institutes of Health activity index (NIH-AI) score >10), from low/moderate lupus nephritis activity status (NIH-AI score ≤10). Results In this mixed racial cohort, high lupus nephritis activity was present in 15 patients (19%), and 71% had proliferative lupus nephritis. Use of the identical RAIL algorithm developed in children resulted in only fair prediction of lupus nephritis activity status of adults (area under the receiver operating characteristic curve (AUC) 0.62). Alternative weightings of the six RAIL UBMs as suggested by logistic regression yielded excellent accuracy to predict lupus nephritis activity status (AUC 0.88). Accuracy of the model did not improve with adjustment of the UBMs for urine creatinine or albumin, and was little influenced by concurrent kidney damage. Conclusions The RAIL UBMs provide excellent prediction of lupus nephritis activity in adults. Age adaption of the RAIL is warranted to optimize its discriminative validity to predict high lupus nephritis activity status non-invasively.

  3. Assessment of self taken swabs versus clinician taken swab cultures for diagnosing gonorrhoea in women: single centre, diagnostic accuracy study.

    PubMed

    Stewart, Catherine M W; Schoeman, Sarah A; Booth, Russell A; Smith, Susan D; Wilcox, Mark H; Wilson, Janet D

    2012-12-12

    To compare gonorrhoea detection by self taken vulvovaginal swabs (tested with nucleic acid amplification tests) with the culture of urethral and endocervical samples taken by clinicians. Prospective study of diagnostic accuracy. 1 sexual health clinic in an urban setting (Leeds Centre for Sexual Health, United Kingdom), between March 2009 and January 2010. Women aged 16 years or older, attending the clinic for sexually transmitted infection (STI) testing and consenting to perform a vulvovaginal swab themselves before routine examination. During examination, clinicians took urethral and endocervical samples for culture and an endocervical swab for nucleic acid amplification testing. Urethra and endocervix samples were analysed by gonococcal culture. Vulvovaginal swabs and endocervical swabs were analysed by the Aptima Combo 2 (AC2) assay; positive results from this assay were confirmed with a second nucleic acid amplification test. Positive confirmation of gonorrhoea. Of 3859 women with complete data and test results, 96 (2.5%) were infected with gonorrhoea (overall test sensitivities: culture 81%, endocervical swabs with AC2 96%, vulvovaginal swabs with AC2 99%). The AC2 assays were more sensitive than culture (P<0.001), but the endocervical and vulvovaginal assays did not differ significantly (P=0.375). Specificity of all Aptima Combo 2 tests was 100%. Of 1625 women who had symptoms suggestive of a bacterial STI, 56 (3.4%) had gonorrhoea (culture 84%, endocervical AC2 100%, vulvovaginal AC2 100%). The AC2 assays were more sensitive than culture (P=0.004), and the endocervical and vulvovaginal assays were equivalent to each other. Of 2234 women who did not have symptoms suggesting a bacterial STI, 40 (1.8%) had gonorrhoea (culture 78%, endocervical AC2 90%, vulvovaginal AC2 98%). The vulvovaginal swab was more sensitive than culture (P=0.008), but there was no difference between the endocervical and vulvovaginal AC2 assays (P=0.375) or between the endocervical AC2 assay and culture (P=0.125). The endocervical swab assay performed less well in women without symptoms of a bacterial STI than in those with symptoms (90% v 100%, P=0.028), whereas the vulvovaginal swab assay performed similarly (98% v 100%, P=0.42). Self taken vulvovaginal swabs analysed by nucleic acid amplification tests are significantly more sensitive at detecting gonorrhoea than culture of clinician taken urethral and endocervical samples, and are equivalent to endocervical swabs analysed by nucleic acid amplification tests. Self taken vulvovaginal swabs are the sample of choice in women without symptoms and have the advantage of being non-invasive. In women who need a clinical examination, either a clinician taken or self taken vulvovaginal swab is recommended.

  4. Diagnostic evaluation of a multiplexed RT-PCR microsphere array assay for the detection of foot-and-mouth disease virus and look-alike disease viruses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hindson, B J; Reid, S M; Baker, B R

    2007-07-26

    A high-throughput multiplexed assay was developed for the differential laboratory diagnosis of foot-and-mouth disease virus (FMDV) from viruses which cause clinically similar diseases of livestock. This assay simultaneously screens for five RNA and two DNA viruses using multiplexed reverse transcription PCR (mRT-PCR) amplification coupled with a microsphere hybridization array and flow-cytometric detection. Two of the seventeen primer-probe sets included in this multiplex assay were adopted from previously characterized real-time RT-PCR (rRT-PCR) assays for FMDV. The diagnostic accuracy of the mRT-PCR was evaluated using 287 field samples, including 248 (true positive n= 213, true negative n=34) from suspect cases of foot-and-mouthmore » disease collected from 65 countries between 1965 and 2006 and 39 true negative samples collected from healthy animals. The mRT-PCR assay results were compared with two singleplex rRT-PCR assays, using virus isolation with antigen-ELISA as the reference method. The diagnostic sensitivity of the mRT-PCR assay for FMDV was 93.9% [95% C.I. 89.8-96.4%], compared to 98.1% [95% C.I. 95.3-99.3%] for the two singleplex rRT-PCR assays used in combination. In addition, the assay could reliably differentiate between FMDV and other vesicular viruses such as swine vesicular disease virus and vesicular exanthema of swine virus. Interestingly, the mRT-PCR detected parapoxvirus (n=2) and bovine viral diarrhea virus (n=2) in clinical samples, demonstrating the screening potential of this mRT-PCR assay to identify viruses in FMDV-negative material not previously recognized using focused single-target rRT-PCR assays.« less

  5. Diagnostic evaluation of a multiplexed RT-PCR microsphere array assay for the detection of foot-and-mouth and look-alike disease viruses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hindson, B J; Baker, B R; Bentley Tammero, L F

    2007-09-18

    A high-throughput multiplexed assay (Multiplex Version 1.0) was developed for the differential laboratory diagnosis of foot-and-mouth disease virus (FMDV) from viruses which cause clinically similar diseases of livestock. This assay simultaneously screens for five RNA and two DNA viruses using multiplexed reverse transcription PCR (mRT-PCR) amplification coupled with a microsphere hybridization array and flow-cytometric detection. Two of the seventeen primer-probe sets included in this multiplex assay were adopted from previously characterized real-time RT-PCR (rRT-PCR) assays for FMDV. The diagnostic accuracy of the mRT-PCR was evaluated using 287 field samples, including 248 (true positive n= 213, true negative n=34) from suspectmore » cases of foot-and-mouth disease collected from 65 countries between 1965 and 2006 and 39 true negative samples collected from healthy animals. The mRT-PCR assay results were compared with two singleplex rRT-PCR assays, using virus isolation with antigen-ELISA as the reference method. The diagnostic sensitivity of the mRT-PCR assay for FMDV was 93.9% [95% C.I. 89.8-96.4%], compared to 98.1% [95% C.I. 95.3-99.3%] for the two singleplex rRTPCR assays used in combination. In addition, the assay could reliably differentiate between FMDV and other vesicular viruses such as swine vesicular disease virus and vesicular exanthema of swine virus. Interestingly, the mRT-PCR detected parapoxvirus (n=2) and bovine viral diarrhea virus (n=2) in clinical samples, demonstrating the screening potential of this mRT-PCR assay to identify viruses in FMDV-negative material not previously recognized using focused single-target rRT-PCR assays.« less

  6. Comparison of Abbott RealTime genotype II, GeneMatrix restriction fragment mass polymorphism and Sysmex HISCL HCV Gr assays for hepatitis C virus genotyping.

    PubMed

    Han, Mi-Soon; Park, Yongjung; Kim, Hyon-Suk

    2017-07-26

    Hepatitis C virus (HCV) genotype is a predictive marker for treatment response. We sequentially evaluated the performances of two nucleic acid amplification tests (NAATs) and one serology assay for HCV genotype: Abbott RealTime genotype II (RealTime II), GeneMatrix restriction fragment mass polymorphism (RFMP), and Sysmex HISCL HCV Gr (HISCL Gr). We examined 281 clinical samples with three assays. The accuracy was assessed using the HCV Genotype Performance Panel PHW204 (SeraCare Life Sciences) for two NAATs. Discrepant cases were re-genotyped by the Versant HCV v.2.0 (line probe 2.0) assay. With the RealTime II assay, clinic samples were analyzed as follows: genotypes 1b (43.1%), 2 (40.2%), 1 subtypes other than 1a and 1b (12.5%), 3 (1.8%), 4 (1.4%), 1a (0.7%), 6 (0.4%), and mixed (1.1%). The RealTime II and RFMP assays showed a type concordance rate of 97.5% (274/281) (κ=0.80) and no significant discordance (p=0.25). Both assays accurately genotyped all samples in the Performance Panel by the subtype level. The HISCL Gr assay showed concordance rates of about 91% (κ<0.40) and statistically significant discordances with two NAATs (p<0.05). In confirmation tests, the results of RFMP assay were the most consistent with those of Versant 2.0 assay. The three HCV assays provided genotyping and serotyping results with good concordance rates. The two NAATs (RealTime II and RFMP) showed comparable performance and good agreement. However, the results of the HISCL Gr assay showed statistically significant differences with those of the NAATs.

  7. Establishment and application of a modified membrane-blot assay for Rhizomucor miehei lipases aimed at improving their methanol tolerance and thermostability.

    PubMed

    He, Dong; Luo, Wen; Wang, Zhiyuan; Lv, Pengmei; Yuan, Zhenhong; Huang, Shaowei; Xv, Jingliang

    2017-07-01

    Directed evolution has been proved an effective way to improve the stability of proteins, but high throughput screening assays for directed evolution with simultaneous improvement of two or more properties are still rare. In this study, we aimed to establish a membrane-blot assay for use in the high-throughput screening of Rhizomucor miehei lipases (RMLs). With the assistance of the membrane-blot screening assay, a mutant E47K named G10 that showed improved thermal stability was detected in the first round of error-prone PCR. Using G10 as the parent, two variants G10-11 and G10-20 that showed improved thermal stability and methanol tolerance without loss of activity compared to the wild type RML were obtained. The T 50 60 -value of G10-11 and G10-20 increased by 12°C and 6.5°C, respectively. After incubation for 1h, the remaining residual activity of G10-11 and G10-20 was 63.45% and 74.33%, respectively, in 50% methanol, and 15.98% and 30.22%, respectively, in 80% methanol. Thus, we successfully developed a membrane-blot assay that could be used for the high-throughput screening of RMLs with improved thermostability and methanol tolerance. Based on our findings, we believe that our newly developed membrane-blot assay will have potential applications in directed evolution in the future. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Reprint of "CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals".

    PubMed

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2018-06-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Key Technical Aspects Influencing the Accuracy of Tablet Subdivision.

    PubMed

    Teixeira, Maíra T; Sá-Barreto, Lívia C L; Gratieri, Taís; Gelfuso, Guilherme M; Silva, Izabel C R; Cunha-Filho, Marcílio S S

    2017-05-01

    Tablet subdivision is a common practice used mainly for dose adjustment. The aim of this study was to investigate how the technical aspects of production as well as the method of tablets subdivision (employing a tablet splitter or a kitchen knife) influence the accuracy of this practice. Five drugs commonly used as subdivided tablets were selected. For each drug, the innovator drug product, a scored-generic and a non-scored generic were investigated totalizing fifteen drug products. Mechanical and physical tests, including image analysis, were performed. Additionally, comparisons were made between tablet subdivision method, score, shape, diluent composition and coating. Image analysis based on surface area was a useful tool as an alternative assay to evaluate the accuracy of tablet subdivision. The tablet splitter demonstrates an advantage relative to a knife as it showed better results in weight loss and friability tests. Oblong, coated and scored tablets had better results after subdivision than round, uncoated and non-scored tablets. The presence of elastic diluents such as starch and dibasic phosphate dehydrate conferred a more appropriate behaviour for the subdivision process than plastic materials such as microcrystalline cellulose and lactose. Finally, differences were observed between generics and their innovator products in all selected drugs with regard the quality control assays in divided tablet, which highlights the necessity of health regulations to consider subdivision performance at least in marketing authorization of generic products.

  10. CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2017-10-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Accuracy of human papillomavirus testing on self-collected versus clinician-collected samples: a meta-analysis.

    PubMed

    Arbyn, Marc; Verdoodt, Freija; Snijders, Peter J F; Verhoef, Viola M J; Suonio, Eero; Dillner, Lena; Minozzi, Silvia; Bellisario, Cristina; Banzi, Rita; Zhao, Fang-Hui; Hillemanns, Peter; Anttila, Ahti

    2014-02-01

    Screening for human papillomavirus (HPV) infection is more effective in reducing the incidence of cervical cancer than screening using Pap smears. Moreover, HPV testing can be done on a vaginal sample self-taken by a woman, which offers an opportunity to improve screening coverage. However, the clinical accuracy of HPV testing on self-samples is not well-known. We assessed whether HPV testing on self-collected samples is equivalent to HPV testing on samples collected by clinicians. We identified relevant studies through a search of PubMed, Embase, and CENTRAL. Studies were eligible for inclusion if they fulfilled all of the following selection criteria: a cervical cell sample was self-collected by a woman followed by a sample taken by a clinician; a high-risk HPV test was done on the self-sample (index test) and HPV-testing or cytological interpretation was done on the specimen collected by the clinician (comparator tests); and the presence or absence of cervical intraepithelial neoplasia grade 2 (CIN2) or worse was verified by colposcopy and biopsy in all enrolled women or in women with one or more positive tests. The absolute accuracy for finding CIN2 or worse, or CIN grade 3 (CIN3) or worse of the index and comparator tests as well as the relative accuracy of the index versus the comparator tests were pooled using bivariate normal models and random effect models. We included data from 36 studies, which altogether enrolled 154 556 women. The absolute accuracy varied by clinical setting. In the context of screening, HPV testing on self-samples detected, on average, 76% (95% CI 69-82) of CIN2 or worse and 84% (72-92) of CIN3 or worse. The pooled absolute specificity to exclude CIN2 or worse was 86% (83-89) and 87% (84-90) to exclude CIN3 or worse. The variation of the relative accuracy of HPV testing on self-samples compared with tests on clinician-taken samples was low across settings, enabling pooling of the relative accuracy over all studies. The pooled sensitivity of HPV testing on self-samples was lower than HPV testing on a clinician-taken sample (ratio 0·88 [95% CI 0·85-0·91] for CIN2 or worse and 0·89 [0·83-0·96] for CIN3 or worse). Also specificity was lower in self-samples versus clinician-taken samples (ratio 0·96 [0·95-0·97] for CIN2 or worse and 0·96 [0·93-0·99] for CIN3 or worse). HPV testing with signal-based assays on self-samples was less sensitive and specific than testing on clinician-based samples. By contrast, some PCR-based HPV tests generally showed similar sensitivity on both self-samples and clinician-based samples. In screening programmes using signal-based assays, sampling by a clinician should be recommended. However, HPV testing on a self-sample can be suggested as an additional strategy to reach women not participating in the regular screening programme. Some PCR-based HPV tests could be considered for routine screening after careful piloting assessing feasibility, logistics, population compliance, and costs. The 7th Framework Programme of the European Commission, the Belgian Foundation against Cancer, the International Agency for Research on Cancer, and the German Guideline Program in Oncology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Cadastral Database Positional Accuracy Improvement

    NASA Astrophysics Data System (ADS)

    Hashim, N. M.; Omar, A. H.; Ramli, S. N. M.; Omar, K. M.; Din, N.

    2017-10-01

    Positional Accuracy Improvement (PAI) is the refining process of the geometry feature in a geospatial dataset to improve its actual position. This actual position relates to the absolute position in specific coordinate system and the relation to the neighborhood features. With the growth of spatial based technology especially Geographical Information System (GIS) and Global Navigation Satellite System (GNSS), the PAI campaign is inevitable especially to the legacy cadastral database. Integration of legacy dataset and higher accuracy dataset like GNSS observation is a potential solution for improving the legacy dataset. However, by merely integrating both datasets will lead to a distortion of the relative geometry. The improved dataset should be further treated to minimize inherent errors and fitting to the new accurate dataset. The main focus of this study is to describe a method of angular based Least Square Adjustment (LSA) for PAI process of legacy dataset. The existing high accuracy dataset known as National Digital Cadastral Database (NDCDB) is then used as bench mark to validate the results. It was found that the propose technique is highly possible for positional accuracy improvement of legacy spatial datasets.

  13. Ribosomal DNA analysis of tsetse and non-tsetse transmitted Ethiopian Trypanosoma vivax strains in view of improved molecular diagnosis.

    PubMed

    Fikru, Regassa; Matetovici, Irina; Rogé, Stijn; Merga, Bekana; Goddeeris, Bruno Maria; Büscher, Philippe; Van Reet, Nick

    2016-04-15

    Animal trypanosomosis caused by Trypanosoma vivax (T. vivax) is a devastating disease causing serious economic losses. Most molecular diagnostics for T. vivax infection target the ribosomal DNA locus (rDNA) but are challenged by the heterogeneity among T. vivax strains. In this study, we investigated the rDNA heterogeneity of Ethiopian T. vivax strains in relation to their presence in tsetse-infested and tsetse-free areas and its effect on molecular diagnosis. We sequenced the rDNA loci of six Ethiopian (three from tsetse-infested and three from tsetse-free areas) and one Nigerian T. vivax strain. We analysed the obtained sequences in silico for primer-mismatches of some commonly used diagnostic PCR assays and for GC content. With these data, we selected some rDNA diagnostic PCR assays for evaluation of their diagnostic accuracy. Furthermore we constructed two phylogenetic networks based on sequences within the smaller subunit (SSU) of 18S and within the 5.8S and internal transcribed spacer 2 (ITS2) to assess the relatedness of Ethiopian T. vivax strains to strains from other African countries and from South America. In silico analysis of the rDNA sequence showed important mismatches of some published diagnostic PCR primers and high GC content of T. vivax rDNA. The evaluation of selected diagnostic PCR assays with specimens from cattle under natural T. vivax challenge showed that this high GC content interferes with the diagnostic accuracy of PCR, especially in cases of mixed infections with T. congolense. Adding betain to the PCR reaction mixture can enhance the amplification of T. vivax rDNA but decreases the sensitivity for T. congolense and Trypanozoon. The networks illustrated that Ethiopian T. vivax strains are considerably heterogeneous and two strains (one from tsetse-infested and one from tsetse-free area) are more related to the West African and South American strains than to the East African strains. The rDNA locus sequence of six Ethiopian T. vivax strains showed important differences and higher GC content compared to other animal trypanosomes but could not be related to their origin from tsetse-infested or tsetse-free area. The high GC content of T. vivax DNA renders accurate diagnosis of all pathogenic animal trypanosomes with one single PCR problematic. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  14. An Innovative Approach to Improving the Accuracy of Delirium Assessments Using the Confusion Assessment Method for the Intensive Care Unit.

    PubMed

    DiLibero, Justin; O'Donoghue, Sharon C; DeSanto-Madeya, Susan; Felix, Janice; Ninobla, Annalyn; Woods, Allison

    2016-01-01

    Delirium occurs in up to 80% of intensive care unit (ICU) patients. Despite its prevalence in this population, there continues to be inaccuracies in delirium assessments. In the absence of accurate delirium assessments, delirium in critically ill ICU patients will remain unrecognized and will lead to negative clinical and organizational outcomes. The goal of this quality improvement project was to facilitate sustained improvement in the accuracy of delirium assessments among all ICU patients including those who were sedate or agitated. A pretest-posttest design was used to evaluate the effectiveness of a program to improve the accuracy of delirium screenings among patients admitted to a medical ICU or coronary care unit. Two hundred thirty-six delirium assessment audits were completed during the baseline period and 535 during the postintervention period. Compliance with performing at least 1 delirium assessment every shift was 85% at baseline and improved to 99% during the postintervention period. Baseline assessment accuracy was 70.31% among all patients and 53.49% among sedate and agitated patients. Postintervention assessment accuracy improved to 95.51% for all patients and 89.23% among sedate and agitated patients. The results from this project suggest the effectiveness of the program in improving assessment accuracy among difficult-to-assess patients. Further research is needed to demonstrate the effectiveness of this model across other critical care units, patient populations, and organizations.

  15. Aqueous two-phase systems enable multiplexing of homogeneous immunoassays

    PubMed Central

    Simon, Arlyne B.; Frampton, John P.; Huang, Nien-Tsu; Kurabayashi, Katsuo; Paczesny, Sophie; Takayama, Shuichi

    2014-01-01

    Quantitative measurement of protein biomarkers is critical for biomarker validation and early disease detection. Current multiplex immunoassays are time consuming costly and can suffer from low accuracy. For example, multiplex ELISAs require multiple, tedious, washing and blocking steps. Moreover, they suffer from nonspecific antibody cross-reactions, leading to high background and false-positive signals. Here, we show that co-localizing antibody-bead pairs in an aqueous two-phase system (ATPS) enables multiplexing of sensitive, no-wash, homogeneous assays, while preventing nonspecific antibody cross-reactions. Our cross-reaction-free, multiplex assay can simultaneously detect picomolar concentrations of four protein biomarkers ((C-X-C motif) ligand 10 (CXCL10), CXCL9, interleukin (IL)-8 and IL-6) in cell supernatants using a single assay well. The potential clinical utility of the assay is demonstrated by detecting diagnostic biomarkers (CXCL10 and CXCL9) in plasma from 88 patients at the onset of the clinical symptoms of chronic graft-versus-host disease (GVHD). PMID:25083509

  16. A scalable double-barcode sequencing platform for characterization of dynamic protein-protein interactions.

    PubMed

    Schlecht, Ulrich; Liu, Zhimin; Blundell, Jamie R; St Onge, Robert P; Levy, Sasha F

    2017-05-25

    Several large-scale efforts have systematically catalogued protein-protein interactions (PPIs) of a cell in a single environment. However, little is known about how the protein interactome changes across environmental perturbations. Current technologies, which assay one PPI at a time, are too low throughput to make it practical to study protein interactome dynamics. Here, we develop a highly parallel protein-protein interaction sequencing (PPiSeq) platform that uses a novel double barcoding system in conjunction with the dihydrofolate reductase protein-fragment complementation assay in Saccharomyces cerevisiae. PPiSeq detects PPIs at a rate that is on par with current assays and, in contrast with current methods, quantitatively scores PPIs with enough accuracy and sensitivity to detect changes across environments. Both PPI scoring and the bulk of strain construction can be performed with cell pools, making the assay scalable and easily reproduced across environments. PPiSeq is therefore a powerful new tool for large-scale investigations of dynamic PPIs.

  17. Development and application of a quantitative multiplexed small GTPase activity assay using targeted proteomics.

    PubMed

    Zhang, Cheng-Cheng; Li, Ru; Jiang, Honghui; Lin, Shujun; Rogalski, Jason C; Liu, Kate; Kast, Juergen

    2015-02-06

    Small GTPases are a family of key signaling molecules that are ubiquitously expressed in various types of cells. Their activity is often analyzed by western blot, which is limited by its multiplexing capability, the quality of isoform-specific antibodies, and the accuracy of quantification. To overcome these issues, a quantitative multiplexed small GTPase activity assay has been developed. Using four different binding domains, this assay allows the binding of up to 12 active small GTPase isoforms simultaneously in a single experiment. To accurately quantify the closely related small GTPase isoforms, a targeted proteomic approach, i.e., selected/multiple reaction monitoring, was developed, and its functionality and reproducibility were validated. This assay was successfully applied to human platelets and revealed time-resolved coactivation of multiple small GTPase isoforms in response to agonists and differential activation of these isoforms in response to inhibitor treatment. This widely applicable approach can be used for signaling pathway studies and inhibitor screening in many cellular systems.

  18. Factors affecting a cyanogen bromide-based assay of thiamin.

    PubMed

    Wyatt, D T; Lee, M; Hillman, R E

    1989-11-01

    We analyzed extensively a modified thiochrome method for thiamin analysis. Acid phosphatase (EC 3.1.3.2) from potato was superior to either alpha-amylase or acid phosphatase from wheat germ as a dephosphorylating agent. Timing of cyanogen bromide exposure was important, but the assay had good precision and accuracy. The standard curve was linear from 10 to 3000 nmol/L. The within-run and between-run coefficients of variation for total thiamin in whole blood were 3.6% and 7.4%, respectively. Analytical recoveries for low, intermediate, and high additions of thiamin to whole blood were 93-109%. Sample yield was increased by 41% (+/- 29% SD) with pre-assay freezing. Samples were stable for two days at room temperature, for seven days when refrigerated, and for two years when frozen. Previously unreported interference was seen with penicillin derivatives, and with several commonly used diuretic and antiepileptic medications. This assay may be suitable for population screening; 200 samples could be analyzed weekly at a cost of +0.20 per sample.

  19. Concept Mapping Improves Metacomprehension Accuracy among 7th Graders

    ERIC Educational Resources Information Center

    Redford, Joshua S.; Thiede, Keith W.; Wiley, Jennifer; Griffin, Thomas D.

    2012-01-01

    Two experiments explored concept map construction as a useful intervention to improve metacomprehension accuracy among 7th grade students. In the first experiment, metacomprehension was marginally better for a concept mapping group than for a rereading group. In the second experiment, metacomprehension accuracy was significantly greater for a…

  20. Improving the Accuracy of Software-Based Energy Analysis for Residential Buildings (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polly, B.

    2011-09-01

    This presentation describes the basic components of software-based energy analysis for residential buildings, explores the concepts of 'error' and 'accuracy' when analysis predictions are compared to measured data, and explains how NREL is working to continuously improve the accuracy of energy analysis methods.

  1. Note: An improved calibration system with phase correction for electronic transformers with digital output.

    PubMed

    Cheng, Han-miao; Li, Hong-bin

    2015-08-01

    The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.

  2. Understanding the delayed-keyword effect on metacomprehension accuracy.

    PubMed

    Thiede, Keith W; Dunlosky, John; Griffin, Thomas D; Wiley, Jennifer

    2005-11-01

    The typical finding from research on metacomprehension is that accuracy is quite low. However, recent studies have shown robust accuracy improvements when judgments follow certain generation tasks (summarizing or keyword listing) but only when these tasks are performed at a delay rather than immediately after reading (K. W. Thiede & M. C. M. Anderson, 2003; K. W. Thiede, M. C. M. Anderson, & D. Therriault, 2003). The delayed and immediate conditions in these studies confounded the delay between reading and generation tasks with other task lags, including the lag between multiple generation tasks and the lag between generation tasks and judgments. The first 2 experiments disentangle these confounded manipulations and provide clear evidence that the delay between reading and keyword generation is the only lag critical to improving metacomprehension accuracy. The 3rd and 4th experiments show that not all delayed tasks produce improvements and suggest that delayed generative tasks provide necessary diagnostic cues about comprehension for improving metacomprehension accuracy.

  3. Techniques for improving the accuracy of cyrogenic temperature measurement in ground test programs

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Fabik, Richard H.

    1993-01-01

    The performance of a sensor is often evaluated by determining to what degree of accuracy a measurement can be made using this sensor. The absolute accuracy of a sensor is an important parameter considered when choosing the type of sensor to use in research experiments. Tests were performed to improve the accuracy of cryogenic temperature measurements by calibration of the temperature sensors when installed in their experimental operating environment. The calibration information was then used to correct for temperature sensor measurement errors by adjusting the data acquisition system software. This paper describes a method to improve the accuracy of cryogenic temperature measurements using corrections in the data acquisition system software such that the uncertainty of an individual temperature sensor is improved from plus or minus 0.90 deg R to plus or minus 0.20 deg R over a specified range.

  4. Improving the accuracy of camber predictions for precast pretensioned concrete beams : [tech transfer summary].

    DOT National Transportation Integrated Search

    2015-07-01

    Implementing the recommendations of this study is expected to significantly : improve the accuracy of camber measurements and predictions and to : ultimately help reduce construction delays, improve bridge serviceability, : and decrease costs.

  5. Head-to-head comparison of the diagnostic accuracies of BD Veritor™ System RSV and Quidel® Sofia® RSV FIA systems for respiratory syncytial virus (RSV) diagnosis.

    PubMed

    Kanwar, Neena; Hassan, Ferdaus; Nguyen, Ashley; Selvarangan, Rangaraj

    2015-04-01

    Respiratory syncytial virus (RSV) is one of the most common causes of severe lower respiratory tract disease among infants and young children. BD Veritor™ System RSV (BD) and Quidel(®) Sofia(®) RSV FIA (QD) are the new generation lateral flow digital immunoassay (DIA) tests with an instrumented read for the qualitative detection of RSV viral antigens. To compare the diagnostic accuracies of BD and QD for RSV detection using fresh nasopharyngeal aspirates and nasopharyngeal swab specimens collected in universal transport media during 2013-2014 respiratory season. The two DIA tests were performed simultaneously on randomly selected specimens on a weekly basis during the RSV season until 200 fresh remnant specimens were enrolled. Real-time RT-PCR assay results were used to compare and evaluate the performance of both RSV DIA assays. Among 200 specimens tested, RSV real-time RT-PCR assay detected RSV in 104 samples, while QD detected 84 samples and BD detected 74 samples as positive. The overall sensitivity for detection of RSV in comparison to PCR was 71.15% (61.3-79.4) for BD and 80.77% (71.6-87.6) for QD system (P=0.36). The specificity was 100% (95.2-100) for both systems. The work flow analysis revealed that the overall specimen processing time was significantly lower for BD as compared with the QD assay. In comparison with the real-time PCR, the QD system showed a higher sensitivity than that of the BD system, but the difference did not reach statistical significance (P=0.36). Both BD and QD systems were found comparable in terms of specificity. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Absolute quantification of prion protein (90-231) using stable isotope-labeled chymotryptic peptide standards in a LC-MRM AQUA workflow.

    PubMed

    Sturm, Robert; Sheynkman, Gloria; Booth, Clarissa; Smith, Lloyd M; Pedersen, Joel A; Li, Lingjun

    2012-09-01

    Substantial evidence indicates that the disease-associated conformer of the prion protein (PrP(TSE)) constitutes the etiologic agent in prion diseases. These diseases affect multiple mammalian species. PrP(TSE) has the ability to convert the conformation of the normal prion protein (PrP(C)) into a β-sheet rich form resistant to proteinase K digestion. Common immunological techniques lack the sensitivity to detect PrP(TSE) at subfemtomole levels, whereas animal bioassays, cell culture, and in vitro conversion assays offer higher sensitivity but lack the high-throughput the immunological assays offer. Mass spectrometry is an attractive alternative to the above assays as it offers high-throughput, direct measurement of a protein's signature peptide, often with subfemtomole sensitivities. Although a liquid chromatography-multiple reaction monitoring (LC-MRM) method has been reported for PrP(TSE), the chemical composition and lack of amino acid sequence conservation of the signature peptide may compromise its accuracy and make it difficult to apply to multiple species. Here, we demonstrate that an alternative protease (chymotrypsin) can produce signature peptides suitable for a LC-MRM absolute quantification (AQUA) experiment. The new method offers several advantages, including: (1) a chymotryptic signature peptide lacking chemically active residues (Cys, Met) that can confound assay accuracy; (2) low attomole limits of detection and quantitation (LOD and LOQ); and (3) a signature peptide retaining the same amino acid sequence across most mammals naturally susceptible to prion infection as well as important laboratory models. To the authors' knowledge, this is the first report on the use of a non-tryptic peptide in a LC-MRM AQUA workflow.

  7. Absolute quantification of prion protein (90-231) using stable isotope-labeled chymotryptic peptide standards in a LC-MRM AQUA workflow

    PubMed Central

    Sturm, Robert; Kreitinger, Gloria; Booth, Clarissa; Smith, Lloyd; Pedersen, Joel; Li, Lingjun

    2012-01-01

    Substantial evidence indicates that the disease-associated conformer of the prion protein (PrPTSE) constitutes the etiological agent in prion diseases. These diseases affect multiple mammalian species. PrPTSE has the ability to convert the conformation of the normal prion protein (PrPC) into a β-sheet rich form resistant to proteinase K digestion. Common immunological techniques lack the sensitivity to detect PrPTSE at sub-femtomole levels while animal bioassays, cell culture, and in vitro conversion assays offer ultrasensitivity but lack the high-throughput the immunological assays offer. Mass spectrometry is an attractive alternative to the above assays as it offers high-throughput, direct measurement of a protein’s signature peptide, often with sub-femtomole sensitivities. Although a liquid chromatography-multiple reaction monitoring (LC-MRM) method has been reported for PrPTSE, the chemical composition and lack of amino acid sequence conservation of the signature peptide may compromise its accuracy and make it difficult to apply to multiple species. Here, we demonstrate that an alternative protease (chymotrypsin) can produce signature peptides suitable for a LC-MRM absolute quantification (AQUA) experiment. The new method offers several advantages, including: (1) a chymotryptic signature peptide lacking chemically active residues (Cys, Met) that can confound assay accuracy; (2) low attomole limits of detection and quantitation (LOD and LOQ); and (3) a signature peptide retaining the same amino acid sequence across most mammals naturally susceptible to prion infection as well as important laboratory models. To the authors’ knowledge, this is the first report of the use of a non-tryptic peptide in a LC-MRM AQUA workflow. PMID:22714949

  8. Absolute Quantification of Prion Protein (90-231) Using Stable Isotope-Labeled Chymotryptic Peptide Standards in a LC-MRM AQUA Workflow

    NASA Astrophysics Data System (ADS)

    Sturm, Robert; Sheynkman, Gloria; Booth, Clarissa; Smith, Lloyd M.; Pedersen, Joel A.; Li, Lingjun

    2012-09-01

    Substantial evidence indicates that the disease-associated conformer of the prion protein (PrPTSE) constitutes the etiologic agent in prion diseases. These diseases affect multiple mammalian species. PrPTSE has the ability to convert the conformation of the normal prion protein (PrPC) into a β-sheet rich form resistant to proteinase K digestion. Common immunological techniques lack the sensitivity to detect PrPTSE at subfemtomole levels, whereas animal bioassays, cell culture, and in vitro conversion assays offer higher sensitivity but lack the high-throughput the immunological assays offer. Mass spectrometry is an attractive alternative to the above assays as it offers high-throughput, direct measurement of a protein's signature peptide, often with subfemtomole sensitivities. Although a liquid chromatography-multiple reaction monitoring (LC-MRM) method has been reported for PrPTSE, the chemical composition and lack of amino acid sequence conservation of the signature peptide may compromise its accuracy and make it difficult to apply to multiple species. Here, we demonstrate that an alternative protease (chymotrypsin) can produce signature peptides suitable for a LC-MRM absolute quantification (AQUA) experiment. The new method offers several advantages, including: (1) a chymotryptic signature peptide lacking chemically active residues (Cys, Met) that can confound assay accuracy; (2) low attomole limits of detection and quantitation (LOD and LOQ); and (3) a signature peptide retaining the same amino acid sequence across most mammals naturally susceptible to prion infection as well as important laboratory models. To the authors' knowledge, this is the first report on the use of a non-tryptic peptide in a LC-MRM AQUA workflow.

  9. Dried Blood Spot Methodology in Combination With Liquid Chromatography/Tandem Mass Spectrometry Facilitates the Monitoring of Teriflunomide

    PubMed Central

    Lunven, Catherine; Turpault, Sandrine; Beyer, Yann-Joel; O'Brien, Amy; Delfolie, Astrid; Boyanova, Neli; Sanderink, Ger-Jan; Baldinetti, Francesca

    2016-01-01

    Background: Teriflunomide, a once-daily oral immunomodulator approved for treatment of relapsing-remitting multiple sclerosis, is eliminated slowly from plasma. If necessary to rapidly lower plasma concentrations of teriflunomide, an accelerated elimination procedure using cholestyramine or activated charcoal may be used. The current bioanalytical assay for determination of plasma teriflunomide concentration requires laboratory facilities for blood centrifugation and plasma storage. An alternative method, with potential for greater convenience, is dried blood spot (DBS) methodology. Analytical and clinical validations are required to switch from plasma to DBS (finger-prick sampling) methodology. Methods: Using blood samples from healthy subjects, an LC-MS/MS assay method for quantification of teriflunomide in DBS over a range of 0.01–10 mcg/mL was developed and validated for specificity, selectivity, accuracy, precision, reproducibility, and stability. Results were compared with those from the current plasma assay for determination of plasma teriflunomide concentration. Results: Method was specific and selective relative to endogenous compounds, with process efficiency ∼88%, and no matrix effect. Inaccuracy and imprecision for intraday and interday analyses were <15% at all concentrations tested. Quantification of teriflunomide in DBS assay was not affected by blood deposit volume and punch position within spot, and hematocrit level had a limited but acceptable effect on measurement accuracy. Teriflunomide was stable for at least 4 months at room temperature, and for at least 24 hours at 37°C with and without 95% relative humidity, to cover sampling, drying, and shipment conditions in the field. The correlation between DBS and plasma concentrations (R2 = 0.97), with an average blood to plasma ratio of 0.59, was concentration independent and constant over time. Conclusions: DBS sampling is a simple and practical method for monitoring teriflunomide concentrations. PMID:27015245

  10. Diagnostic accuracy of two multiplex real-time polymerase chain reaction assays for the diagnosis of meningitis in children in a resource-limited setting.

    PubMed

    Khumalo, Jermaine; Nicol, Mark; Hardie, Diana; Muloiwa, Rudzani; Mteshana, Phindile; Bamford, Colleen

    2017-01-01

    Accurate etiological diagnosis of meningitis is important, but difficult in resource-limited settings due to prior administration of antibiotics and lack of viral diagnostics. We aimed to develop and validate 2 real-time multiplex PCR (RT-PCR) assays for the detection of common causes of community-acquired bacterial and viral meningitis in South African children. We developed 2 multiplex RT- PCRs for detection of S. pneumoniae, N. meningitidis, H. influenzae, enteroviruses, mumps virus and herpes simplex virus. We tested residual CSF samples from children presenting to a local paediatric hospital over a one-year period, whose CSF showed an abnormal cell count. Results were compared with routine diagnostic tests and the final discharge diagnosis. We calculated accuracy of the bacterial RT-PCR assay compared to CSF culture and using World Health Organisation definitions of laboratory-confirmed bacterial meningitis. From 292 samples, bacterial DNA was detected in 12 (4.1%) and viral nucleic acids in 94 (32%). Compared to CSF culture, the sensitivity and specificity of the bacterial RT-PCR was 100% and 97.2% with complete agreement in organism identification. None of the cases positive by viral RT-PCR had a bacterial cause confirmed on CSF culture. Only 9/90 (10%) of patients diagnosed clinically as bacterial meningitis or partially treated bacterial meningitis tested positive with the bacterial RT-PCR. In this population the use of 2 multiplex RT-PCRs targeting 6 common pathogens gave promising results. If introduced into routine diagnostic testing, these multiplex RT-PCR assays would supplement other diagnostic tests, and have the potential to limit unnecessary antibiotic therapy and hospitalisation.

  11. Characterization and application of restricted access carbon nanotubes in online extraction of anticonvulsant drugs from plasma samples followed by liquid chromatography analysis.

    PubMed

    Dos Santos, Rodrigo Campos; Kakazu, Adriana Kaori; Santos, Mariane Gonçalves; Belinelli Silva, Fábio Antônio; Figueiredo, Eduardo Costa

    2017-06-01

    Anticonvulsant drugs are often used in the treatment of epilepsy. However, their therapeutic monitoring is often necessary in order to obtain an appropriate dose adjustment, due to the proximity between their therapeutic and toxic ranges. The aim of this study was to carry out the synthesis, characterization and use of restricted access carbon nanotubes (RACNTs) in an online method for the analyses of phenobarbital and carbamazepine and primidone from untreated human blood plasma by column switching liquid chromatography. Therefore, the synthesis of RACNTs was carried out through coating commercial Carbon nanotubes with bovine serum albumin (BSA) to subsequently use them as adsorbents in a column switching system operating in the backflush mode. This material was evaluated through the construction of the kinetic and isotherm curves. The experimental data for the interaction of primidone with RACNTs were adequately adjusted to the chemisorption and Sips models for the kinetic and adsorption studies, respectively. The analytical curves ranged from 2.0 to 40.0mgL -1 , with correlation coefficients higher than 0.99, for all the analytes. The LODs of 0.1, 0.1 and 0.01μgmL -1 were defined for PHB, PRM and CBZ, respectively. The relative standard deviation values ranged from 1.0% to 8.4% for the intra assay precision and from 2.7% to 7.6% for inter assay precision. The relative error values ranged from -13.4% to 7.7% for the intra assay accuracy and from -8.6% to 2.5% for the inter assay accuracy. The method was adequately used in the therapeutic monitoring of anticonvulsant drugs in human plasma samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Diagnostic accuracy of two multiplex real-time polymerase chain reaction assays for the diagnosis of meningitis in children in a resource-limited setting

    PubMed Central

    Khumalo, Jermaine; Nicol, Mark; Hardie, Diana; Muloiwa, Rudzani; Mteshana, Phindile

    2017-01-01

    Introduction Accurate etiological diagnosis of meningitis is important, but difficult in resource-limited settings due to prior administration of antibiotics and lack of viral diagnostics. We aimed to develop and validate 2 real-time multiplex PCR (RT-PCR) assays for the detection of common causes of community-acquired bacterial and viral meningitis in South African children. Methods We developed 2 multiplex RT- PCRs for detection of S. pneumoniae, N. meningitidis, H. influenzae, enteroviruses, mumps virus and herpes simplex virus. We tested residual CSF samples from children presenting to a local paediatric hospital over a one-year period, whose CSF showed an abnormal cell count. Results were compared with routine diagnostic tests and the final discharge diagnosis. We calculated accuracy of the bacterial RT-PCR assay compared to CSF culture and using World Health Organisation definitions of laboratory-confirmed bacterial meningitis. Results From 292 samples, bacterial DNA was detected in 12 (4.1%) and viral nucleic acids in 94 (32%). Compared to CSF culture, the sensitivity and specificity of the bacterial RT-PCR was 100% and 97.2% with complete agreement in organism identification. None of the cases positive by viral RT-PCR had a bacterial cause confirmed on CSF culture. Only 9/90 (10%) of patients diagnosed clinically as bacterial meningitis or partially treated bacterial meningitis tested positive with the bacterial RT-PCR. Discussion In this population the use of 2 multiplex RT-PCRs targeting 6 common pathogens gave promising results. If introduced into routine diagnostic testing, these multiplex RT-PCR assays would supplement other diagnostic tests, and have the potential to limit unnecessary antibiotic therapy and hospitalisation. PMID:28346504

  13. Assessment of the predictive capacity of the optimized in vitro comet assay using HepG2 cells.

    PubMed

    Hong, Yoon-Hee; Jeon, Hye Lyun; Ko, Kyung Yuk; Kim, Joohwan; Yi, Jung-Sun; Ahn, Ilyoung; Kim, Tae Sung; Lee, Jong Kwon

    2018-03-01

    Evaluation of DNA damage is critical during the development of new drugs because it is closely associated with genotoxicity and carcinogenicity. The in vivo comet assay to assess DNA damage is globally harmonized as OECD TG 489. However, a comet test guideline that evaluates DNA damage without sacrificing animals does not yet exist. The goal of this study was to select an appropriate cell line for optimization of the in vitro comet assay to assess DNA damage. We then evaluated the predictivity of the in vitro comet assay using the selected cell line. In addition, the effect of adding S9 was evaluated using 12 test chemicals. For cell line selection, HepG2, Chinese hamster lung (CHL/IU), and TK6 cell lines were evaluated. We employed a method for the in vitro comet assay based on that for the in vivo comet assay. The most appropriate cell line was determined by% tail DNA increase after performing in vitro comet assays with 6 test chemicals. The predictivity of the in vitro comet assay using the selected cell line was measured with 10 test chemicals (8 genotoxins and 2 non-genotoxic chemicals). The HepG2 cell line was found to be the most appropriate, and in vitro comet assays using HepG2 cells exhibited a high accuracy of 90% (9/10). This study suggests that HepG2 is an optimal cell line for the in vitro comet assay to assess DNA damage. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. A novel reporter gene assay for recombinant human erythropoietin (rHuEPO) pharmaceutical products.

    PubMed

    Yang, Yushuai; Zhou, Yong; Yu, Lei; Li, Xiang; Shi, Xinchang; Qin, Xi; Rao, Chunming; Wang, Junzhi

    2014-11-01

    Accurate determination of in vitro biological activity of therapeutic erythropoietin is essential in quality control of recombinant human erythropoietin (rHuEPO) pharmaceutical products. However, most of currently-used methods leave much to be desired so that a simpler, quicker and more accurate method is urgently needed. The bioassay described here utilizes a sub clone of UT-7/epo cell line stably transfected with luciferase gene under the control of sis inducible element and interferon γ-activated sequence element promoter. Active erythropoietin could induce the expression of luciferase by signaling through the erythropoietin receptor and the dose-response curve showed good linearity, yielding a coefficient of determination of 0.99 or higher. The optimized assay was simpler with the operation completed within 24h and more sensitive with EC50 being 0.077IU/mL. The accuracy estimates ranged from 81.7% to 102.4%, and both intra-assay and inter-assay precision was below 15.0%. The robustness of the assay was demonstrated by no effect of passage levels of the cells on the performance of the assay (p values: 0.772 for sample 1 and 0.943 for sample 2). Besides, Bland-Altman analysis showed a high consistency of the new assay with in vivo reticulocyte assay in results. These results suggested that the new reporter gene assay can be a viable supplement to the traditional reticulocyte assay and employed in potency determination of rHuEPO pharmaceutical products. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Performance characteristics of the ARCHITECT anti-HCV assay.

    PubMed

    Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter

    2005-10-01

    The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.

  16. Quantitative assessment of hematopoietic chimerism by quantitative real-time polymerase chain reaction of sequence polymorphism systems after hematopoietic stem cell transplantation.

    PubMed

    Qin, Xiao-ying; Li, Guo-xuan; Qin, Ya-zhen; Wang, Yu; Wang, Feng-rong; Liu, Dai-hong; Xu, Lan-ping; Chen, Huan; Han, Wei; Wang, Jing-zhi; Zhang, Xiao-hui; Li, Jin-lan; Li, Ling-di; Liu, Kai-yan; Huang, Xiao-jun

    2011-08-01

    Analysis of changes in recipient and donor hematopoietic cell origin is extremely useful to monitor the effect of hematopoietic stem cell transplantation (HSCT) and sequential adoptive immunotherapy by donor lymphocyte infusions. We developed a sensitive, reliable and rapid real-time PCR method based on sequence polymorphism systems to quantitatively assess the hematopoietic chimerism after HSCT. A panel of 29 selected sequence polymorphism (SP) markers was screened by real-time PCR in 101 HSCT patients with leukemia and other hematological diseases. The chimerism kinetics of bone marrow samples of 8 HSCT patients in remission and relapse situations were followed longitudinally. Recipient genotype discrimination was possible in 97.0% (98 of 101) with a mean number of 2.5 (1-7) informative markers per recipient/donor pair. Using serial dilutions of plasmids containing specific SP markers, the linear correlation (r) of 0.99, the slope between -3.2 and -3.7 and the sensitivity of 0.1% were proved reproducible. By this method, it was possible to very accurately detect autologous signals in the range from 0.1% to 30%. The accuracy of the method in the very important range of autologous signals below 5% was extraordinarily high (standard deviation <1.85%), which might significantly improve detection accuracy of changes in autologous signals early in the post-transplantation course of follow-up. The main advantage of the real-time PCR method over short tandem repeat PCR chimerism assays is the absence of PCR competition and plateau biases, with demonstrated greater sensitivity and linearity. Finally, we prospectively analyzed bone marrow samples of 8 patients who received allografts and presented the chimerism kinetics of remission and relapse situations that illustrated the sensitivity level and the promising clinical application of this method. This SP-based real-time PCR assay provides a rapid, sensitive, and accurate quantitative assessment of mixed chimerism that can be useful in predicting graft rejection and early relapse.

  17. Clinically inappropriate post hoc exclusion of study participants from test accuracy calculations: the ROMA score, an example from a recent NICE diagnostic assessment.

    PubMed

    Lang, Shona; Armstrong, Nigel; Deshpande, Sohan; Ramaekers, Bram; Grimm, Sabine; de Kock, Shelley; Kleijnen, Jos; Westwood, Marie

    2018-01-01

    Objective To explore how the definition of the target condition and post hoc exclusion of participants can limit the usefulness of diagnostic accuracy studies. Methods We used data from a systematic review, conducted for a NICE diagnostic assessment of risk scores to inform secondary care decisions about specialist referral for women with suspected ovarian cancer, to explore how the definition of the target condition and post hoc exclusion of participants can limit the usefulness of diagnostic accuracy studies to inform clinical practice. Results Fourteen of the studies evaluated the ROMA score, nine used Abbott ARCHITECT tumour marker assays, five used Roche Elecsys. The summary sensitivity estimate (Abbott ARCHITECT) was highest, 95.1% (95% CI: 92.4 to 97.1%), where analyses excluded participants with borderline tumours or malignancies other than epithelial ovarian cancer and lowest, 75.0% (95% CI: 60.4 to 86.4%), where all participants were included. Results were similar for Roche Elecsys tumour marker assays. Although the number of patients involved was small, data from studies that reported diagnostic accuracy for both the whole study population and with post hoc exclusion of those with borderline or non-epithelial malignancies suggested that patients with borderline or malignancies other than epithelial ovarian cancer accounts for between 50 and 85% of false-negative ROMA scores. Conclusions Our results illustrate the potential consequences of inappropriate population selection in diagnostic studies; women with non-epithelial ovarian cancers or non-ovarian primaries, and those borderline tumours may be disproportionately represented among those with false negative, 'low risk' ROMA scores. These observations highlight the importance of giving careful consideration to how the target condition has been defined when assessing whether the diagnostic accuracy estimates reported in clinical studies will translate into clinical utility in real-world settings.

  18. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay*

    PubMed Central

    DALBY, TINE; SØRENSEN, CHARLOTTE; PETERSEN, JESPER WESTPHAL; KROGFELT, KAREN ANGELIKI

    2010-01-01

    Dalby T, Sørensen C, Petersen JW, Krogfelt KA. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay. APMIS 2010; 118: 968–72. Two types of serological assays are commonly used for the assessment of pertussis vaccine-induced antibodies; the Chinese hamster ovary cell (CHO cell) assay and the immunoglobulin G (IgG) anti pertussis toxin (PT) enzyme-linked immunosorbent assay (IgG anti-PT ELISA). Recently, both the techniques have been modified to improve performance with sera with interfering activity (CHO cell assay) or with heat-treated sera (IgG anti-PT ELISA). These two improved techniques were compared by the analysis of 100 individual serum samples from a previous clinical trial and 213 sera from a longitudinal serum collection from 20 Danish adults recently vaccinated with the Danish acellular pertussis vaccine. The comparison showed a significant linear correlation between the results of the two assays with a p-value of <0.0001 for the 100 individual samples. We, therefore, conclude that the improved IgG anti-PT ELISA can be used as a replacement for the often troublesome and time-consuming CHO cell assay for the measurement of vaccine-induced human antibodies to PT. PMID:21091778

  19. Economic Impact of Increased Utilization of Multivariate Assay Testing to Guide the Treatment of Ovarian Cancer: Implications for Payers.

    PubMed

    Brodsky, Burton S; Owens, Gary M; Scotti, Dennis J; Needham, Keith A; Cool, Christina L

    2017-10-01

    Ovarian cancer is the eighth most common cancer among women, but ranks fifth in cancer-related causes of death, the majority of which are detected in late stages, after the cancer has metastasized. The CA125 test is the standard of care for assessing suspicious pelvic masses. However, the primary use of CA125 is to monitor treatment progress rather than to screen for disease, and its sensitivity is exceedingly low, unlike the multivariate assay OVA1. A cost-effective treatment of ovarian cancer requires early and accurate diagnosis of pelvic masses and reduced referrals of patients with benign tumors to a gynecologic oncologist. To analyze the economic impact of increased utilization of a multivariate assay, such as OVA1, to guide the treatment of ovarian cancer. The study population was drawn from Medicare and commercial health plan claims data. A budget impact model was constructed to estimate the economic consequences of substituting the multivariate assay OVA1 to replace the single biomarker assay CA125 to assess the likelihood of pelvic mass malignancy in premenopausal and/or postmenopausal women. All patients selected for the analysis had CA125 testing before surgical intervention. A total of 92,843 health plan members were included for analysis, comprising 48,113 commercially insured members and 44,730 Medicare beneficiaries. Estimates of future health plan expenditures, which were calculated from base-case assumptions, projected overall savings of $0.05 per-member per-month (PMPM) for commercially insured members and $0.01 PMPM for Medicare beneficiaries as a result of increased utilization of OVA1. Sensitivity analysis revealed potential savings of up to $0.17 PMPM for commercially insured patients and up to $0.05 for Medicare beneficiaries. The results of the budget impact model support the use of OVA1 instead of CA125 by indicating that modest cost-savings can be achieved, while reaping the clinical benefits of improved diagnostic accuracy, early disease detection, and reductions in multiple, and possibly unnecessary, referrals to gynecologic oncologists.

  20. Evaluation of molecular markers for Phytophthora ramorum detection and identification: testing for specificity using a standardized library of isolates.

    PubMed

    Martin, F N; Coffey, M D; Zeller, K; Hamelin, R C; Tooley, P; Garbelotto, M; Hughes, K J D; Kubisiak, T; Bilodeau, G J; Levy, L; Blomquist, C; Berger, P H

    2009-04-01

    Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World Phytophthora Genetic Resource Collection for 315 isolates representing 60 described Phytophthora spp. as well as 11 taxonomically unclassified isolates. These were sent blind to collaborators in seven laboratories to evaluate published diagnostic procedures using conventional (based on internal transcribed spacer [ITS] and cytochrome oxidase gene [cox]1 and 2 spacer regions) and real-time polymerase chain reaction (based on ITS and cox1 and 2 spacer regions as well as beta-tubulin and elicitin genes). Single-strand conformation polymorphism (SSCP) analysis using an automated sequencer for data collection was also evaluated for identification of all species tested. In general, the procedures worked well, with varying levels of specificity observed among the different techniques. With few exceptions, all assays correctly identified all isolates of P. ramorum and low levels of false positives were observed for the mitochondrial cox spacer markers and most of the real-time assays based on nuclear markers (diagnostic specificity between 96.9 and 100%). The highest level of false positives was obtained with the conventional nested ITS procedure; however, this technique is not stand-alone and is used in conjunction with two other assays for diagnostic purposes. The results indicated that using multiple assays improved the accuracy of the results compared with looking at a single assay alone, in particular when the markers represented different genetic loci. The SSCP procedure accurately identified P. ramorum and was helpful in classification of a number of isolates to a species level. With one exception, all procedures accurately identified P. ramorum in blind evaluations of 60 field samples that included examples of plant infection by 11 other Phytophthora spp. The SSCP analysis identified eight of these species, with three identified to a species group.

Top