Parts and Components Reliability Assessment: A Cost Effective Approach
NASA Technical Reports Server (NTRS)
Lee, Lydia
2009-01-01
System reliability assessment is a methodology which incorporates reliability analyses performed at parts and components level such as Reliability Prediction, Failure Modes and Effects Analysis (FMEA) and Fault Tree Analysis (FTA) to assess risks, perform design tradeoffs, and therefore, to ensure effective productivity and/or mission success. The system reliability is used to optimize the product design to accommodate today?s mandated budget, manpower, and schedule constraints. Stand ard based reliability assessment is an effective approach consisting of reliability predictions together with other reliability analyses for electronic, electrical, and electro-mechanical (EEE) complex parts and components of large systems based on failure rate estimates published by the United States (U.S.) military or commercial standards and handbooks. Many of these standards are globally accepted and recognized. The reliability assessment is especially useful during the initial stages when the system design is still in the development and hard failure data is not yet available or manufacturers are not contractually obliged by their customers to publish the reliability estimates/predictions for their parts and components. This paper presents a methodology to assess system reliability using parts and components reliability estimates to ensure effective productivity and/or mission success in an efficient manner, low cost, and tight schedule.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bucknor, Matthew; Grabaskas, David; Brunett, Acacia
2015-04-26
Advanced small modular reactor designs include many advantageous design features such as passively driven safety systems that are arguably more reliable and cost effective relative to conventional active systems. Despite their attractiveness, a reliability assessment of passive systems can be difficult using conventional reliability methods due to the nature of passive systems. Simple deviations in boundary conditions can induce functional failures in a passive system, and intermediate or unexpected operating modes can also occur. As part of an ongoing project, Argonne National Laboratory is investigating various methodologies to address passive system reliability. The Reliability Method for Passive Systems (RMPS), amore » systematic approach for examining reliability, is one technique chosen for this analysis. This methodology is combined with the Risk-Informed Safety Margin Characterization (RISMC) approach to assess the reliability of a passive system and the impact of its associated uncertainties. For this demonstration problem, an integrated plant model of an advanced small modular pool-type sodium fast reactor with a passive reactor cavity cooling system is subjected to a station blackout using RELAP5-3D. This paper discusses important aspects of the reliability assessment, including deployment of the methodology, the uncertainty identification and quantification process, and identification of key risk metrics.« less
Advanced Reactor PSA Methodologies for System Reliability Analysis and Source Term Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, D.; Brunett, A.; Passerini, S.
Beginning in 2015, a project was initiated to update and modernize the probabilistic safety assessment (PSA) of the GE-Hitachi PRISM sodium fast reactor. This project is a collaboration between GE-Hitachi and Argonne National Laboratory (Argonne), and funded in part by the U.S. Department of Energy. Specifically, the role of Argonne is to assess the reliability of passive safety systems, complete a mechanistic source term calculation, and provide component reliability estimates. The assessment of passive system reliability focused on the performance of the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedback mechanisms of the metal fuel core. Themore » mechanistic source term assessment attempted to provide a sequence specific source term evaluation to quantify offsite consequences. Lastly, the reliability assessment focused on components specific to the sodium fast reactor, including electromagnetic pumps, intermediate heat exchangers, the steam generator, and sodium valves and piping.« less
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason R.
2014-01-01
NASA has highlighted reliability as critical to future human space exploration, particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However, no consensus has been reached on what is meant by improving on reliability, or on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the spring of 2013, the AES Water Recovery Project hosted a series of events at Johnson Space Center with the intended goal of establishing a common language and understanding of NASA's reliability goals, and equipping the projects with acceptable means of assessing the respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools, and techniques associated with evaluating and designing for system reliability. The campaign culminated in a workshop that included members of the Environmental Control and Life Support System and AES communities. The goal of this workshop was to develop a consensus on what reliability means to AES and identify methods for assessing low- to mid-technology readiness level technologies for reliability. This paper details the results of that workshop.
Assessment of reliability and safety of a manufacturing system with sequential failures is an important issue in industry, since the reliability and safety of the system depend not only on all failed states of system components, but also on the sequence of occurrences of those...
18 CFR 39.11 - Reliability reports.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Electric Reliability Organization shall conduct assessments of the adequacy of the Bulk-Power System in... assessments as determined by the Commission of the reliability of the Bulk-Power System in North America and... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Reliability reports. 39...
Reliability of human-supervised formant-trajectory measurement for forensic voice comparison.
Zhang, Cuiling; Morrison, Geoffrey Stewart; Ochoa, Felipe; Enzinger, Ewald
2013-01-01
Acoustic-phonetic approaches to forensic voice comparison often include human-supervised measurement of vowel formants, but the reliability of such measurements is a matter of concern. This study assesses the within- and between-supervisor variability of three sets of formant-trajectory measurements made by each of four human supervisors. It also assesses the validity and reliability of forensic-voice-comparison systems based on these measurements. Each supervisor's formant-trajectory system was fused with a baseline mel-frequency cepstral-coefficient system, and performance was assessed relative to the baseline system. Substantial improvements in validity were found for all supervisors' systems, but some supervisors' systems were more reliable than others.
Integrated performance and reliability specification for digital avionics systems
NASA Technical Reports Server (NTRS)
Brehm, Eric W.; Goettge, Robert T.
1995-01-01
This paper describes an automated tool for performance and reliability assessment of digital avionics systems, called the Automated Design Tool Set (ADTS). ADTS is based on an integrated approach to design assessment that unifies traditional performance and reliability views of system designs, and that addresses interdependencies between performance and reliability behavior via exchange of parameters and result between mathematical models of each type. A multi-layer tool set architecture has been developed for ADTS that separates the concerns of system specification, model generation, and model solution. Performance and reliability models are generated automatically as a function of candidate system designs, and model results are expressed within the system specification. The layered approach helps deal with the inherent complexity of the design assessment process, and preserves long-term flexibility to accommodate a wide range of models and solution techniques within the tool set structure. ADTS research and development to date has focused on development of a language for specification of system designs as a basis for performance and reliability evaluation. A model generation and solution framework has also been developed for ADTS, that will ultimately encompass an integrated set of analytic and simulated based techniques for performance, reliability, and combined design assessment.
Reliability and maintainability assessment factors for reliable fault-tolerant systems
NASA Technical Reports Server (NTRS)
Bavuso, S. J.
1984-01-01
A long term goal of the NASA Langley Research Center is the development of a reliability assessment methodology of sufficient power to enable the credible comparison of the stochastic attributes of one ultrareliable system design against others. This methodology, developed over a 10 year period, is a combined analytic and simulative technique. An analytic component is the Computer Aided Reliability Estimation capability, third generation, or simply CARE III. A simulative component is the Gate Logic Software Simulator capability, or GLOSS. The numerous factors that potentially have a degrading effect on system reliability and the ways in which these factors that are peculiar to highly reliable fault tolerant systems are accounted for in credible reliability assessments. Also presented are the modeling difficulties that result from their inclusion and the ways in which CARE III and GLOSS mitigate the intractability of the heretofore unworkable mathematics.
ECLSS Reliability for Long Duration Missions Beyond Lower Earth Orbit
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason
2014-01-01
Reliability has been highlighted by NASA as critical to future human space exploration particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However there is no consensus on what is meant by improving on reliability; nor on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the spring of 2013, the AES Water Recovery Project (WRP) hosted a series of events at the NASA Johnson Space Center (JSC) with the intended goal of establishing a common language and understanding of our reliability goals, and equipping the projects with acceptable means of assessing our respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools and techniques associated with evalauating and designing for system reliability. The campaign culminated in a workshop at JSC with members of the ECLSS and AES communities with the goal of developing a consensus on what reliability means to AES and identifying methods for assessing our low to mid-technology readiness level (TRL) technologies for reliability. This paper details the results of the workshop.
ECLSS Reliability for Long Duration Missions Beyond Lower Earth Orbit
NASA Technical Reports Server (NTRS)
Sargusingh, Miriam J.; Nelson, Jason
2014-01-01
Reliability has been highlighted by NASA as critical to future human space exploration particularly in the area of environmental controls and life support systems. The Advanced Exploration Systems (AES) projects have been encouraged to pursue higher reliability components and systems as part of technology development plans. However, there is no consensus on what is meant by improving on reliability; nor on how to assess reliability within the AES projects. This became apparent when trying to assess reliability as one of several figures of merit for a regenerable water architecture trade study. In the Spring of 2013, the AES Water Recovery Project (WRP) hosted a series of events at the NASA Johnson Space Center (JSC) with the intended goal of establishing a common language and understanding of our reliability goals and equipping the projects with acceptable means of assessing our respective systems. This campaign included an educational series in which experts from across the agency and academia provided information on terminology, tools and techniques associated with evaluating and designing for system reliability. The campaign culminated in a workshop at JSC with members of the ECLSS and AES communities with the goal of developing a consensus on what reliability means to AES and identifying methods for assessing our low to mid-technology readiness level (TRL) technologies for reliability. This paper details the results of the workshop.
Advanced reliability modeling of fault-tolerant computer-based systems
NASA Technical Reports Server (NTRS)
Bavuso, S. J.
1982-01-01
Two methodologies for the reliability assessment of fault tolerant digital computer based systems are discussed. The computer-aided reliability estimation 3 (CARE 3) and gate logic software simulation (GLOSS) are assessment technologies that were developed to mitigate a serious weakness in the design and evaluation process of ultrareliable digital systems. The weak link is based on the unavailability of a sufficiently powerful modeling technique for comparing the stochastic attributes of one system against others. Some of the more interesting attributes are reliability, system survival, safety, and mission success.
Metrics for Assessing the Reliability of a Telemedicine Remote Monitoring System
Fox, Mark; Papadopoulos, Amy; Crump, Cindy
2013-01-01
Abstract Objective: The goal of this study was to assess using new metrics the reliability of a real-time health monitoring system in homes of older adults. Materials and Methods: The “MobileCare Monitor” system was installed into the homes of nine older adults >75 years of age for a 2-week period. The system consisted of a wireless wristwatch-based monitoring system containing sensors for location, temperature, and impacts and a “panic” button that was connected through a mesh network to third-party wireless devices (blood pressure cuff, pulse oximeter, weight scale, and a survey-administering device). To assess system reliability, daily phone calls instructed participants to conduct system tests and reminded them to fill out surveys and daily diaries. Phone reports and participant diary entries were checked against data received at a secure server. Results: Reliability metrics assessed overall system reliability, data concurrence, study effectiveness, and system usability. Except for the pulse oximeter, system reliability metrics varied between 73% and 92%. Data concurrence for proximal and distal readings exceeded 88%. System usability following the pulse oximeter firmware update varied between 82% and 97%. An estimate of watch-wearing adherence within the home was quite high, about 80%, although given the inability to assess watch-wearing when a participant left the house, adherence likely exceeded the 10 h/day requested time. In total, 3,436 of 3,906 potential measurements were obtained, indicating a study effectiveness of 88%. Conclusions: The system was quite effective in providing accurate remote health data. The different system reliability measures identify important error sources in remote monitoring systems. PMID:23611640
NASA Astrophysics Data System (ADS)
Abdenov, A. Zh; Trushin, V. A.; Abdenova, G. A.
2018-01-01
The paper considers the questions of filling the relevant SIEM nodes based on calculations of objective assessments in order to improve the reliability of subjective expert assessments. The proposed methodology is necessary for the most accurate security risk assessment of information systems. This technique is also intended for the purpose of establishing real-time operational information protection in the enterprise information systems. Risk calculations are based on objective estimates of the adverse events implementation probabilities, predictions of the damage magnitude from information security violations. Calculations of objective assessments are necessary to increase the reliability of the proposed expert assessments.
NASA Astrophysics Data System (ADS)
Chen, Fan; Huang, Shaoxiong; Ding, Jinjin; Ding, Jinjin; Gao, Bo; Xie, Yuguang; Wang, Xiaoming
2018-01-01
This paper proposes a fast reliability assessing method for distribution grid with distributed renewable energy generation. First, the Weibull distribution and the Beta distribution are used to describe the probability distribution characteristics of wind speed and solar irradiance respectively, and the models of wind farm, solar park and local load are built for reliability assessment. Then based on power system production cost simulation probability discretization and linearization power flow, a optimal power flow objected with minimum cost of conventional power generation is to be resolved. Thus a reliability assessment for distribution grid is implemented fast and accurately. The Loss Of Load Probability (LOLP) and Expected Energy Not Supplied (EENS) are selected as the reliability index, a simulation for IEEE RBTS BUS6 system in MATLAB indicates that the fast reliability assessing method calculates the reliability index much faster with the accuracy ensured when compared with Monte Carlo method.
Apples to Apples: Equivalent-Reliability Power Systems Across Diverse Resource Mix Scenarios
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stephen, Gordon W; Frew, Bethany A; Sigler, Devon
Electricity market research is highly price sensitive, and prices are strongly influenced by balance of supply and demand. This work looks at how to combine capacity expansion models and reliability assessment tools to assess equivalent-reliability power systems across diverse resource mix scenarios.
Time-Tagged Risk/Reliability Assessment Program for Development and Operation of Space System
NASA Astrophysics Data System (ADS)
Kubota, Yuki; Takegahara, Haruki; Aoyagi, Junichiro
We have investigated a new method of risk/reliability assessment for development and operation of space system. It is difficult to evaluate risk of spacecraft, because of long time operation, maintenance free and difficulty of test under the ground condition. Conventional methods are FMECA, FTA, ETA and miscellaneous. These are not enough to assess chronological anomaly and there is a problem to share information during R&D. A new method of risk and reliability assessment, T-TRAP (Time-tagged Risk/Reliability Assessment Program) is proposed as a management tool for the development and operation of space system. T-TRAP consisting of time-resolved Fault Tree and Criticality Analyses, upon occurrence of anomaly in the system, facilitates the responsible personnel to quickly identify the failure cause and decide corrective actions. This paper describes T-TRAP method and its availability.
Assessment of physical server reliability in multi cloud computing system
NASA Astrophysics Data System (ADS)
Kalyani, B. J. D.; Rao, Kolasani Ramchand H.
2018-04-01
Business organizations nowadays functioning with more than one cloud provider. By spreading cloud deployment across multiple service providers, it creates space for competitive prices that minimize the burden on enterprises spending budget. To assess the software reliability of multi cloud application layered software reliability assessment paradigm is considered with three levels of abstractions application layer, virtualization layer, and server layer. The reliability of each layer is assessed separately and is combined to get the reliability of multi-cloud computing application. In this paper, we focused on how to assess the reliability of server layer with required algorithms and explore the steps in the assessment of server reliability.
ERIC Educational Resources Information Center
Ghazali, Nor Hasnida Md
2016-01-01
A valid, reliable and practical instrument is needed to evaluate the implementation of the school-based assessment (SBA) system. The aim of this study is to develop and assess the validity and reliability of an instrument to measure the perception of teachers towards the SBA implementation in schools. The instrument is developed based on a…
Dwyer, Tim; Martin, C Ryan; Kendra, Rita; Sermer, Corey; Chahal, Jaskarndip; Ogilvie-Harris, Darrell; Whelan, Daniel; Murnaghan, Lucas; Nauth, Aaron; Theodoropoulos, John
2017-06-01
To determine the interobserver reliability of the International Cartilage Repair Society (ICRS) grading system of chondral lesions in cadavers, to determine the intraobserver reliability of the ICRS grading system comparing arthroscopy and video assessment, and to compare the arthroscopic ICRS grading system with histological grading of lesion depth. Eighteen lesions in 5 cadaveric knee specimens were arthroscopically graded by 7 fellowship-trained arthroscopic surgeons using the ICRS classification system. The arthroscopic video of each lesion was sent to the surgeons 6 weeks later for repeat grading and determination of intraobserver reliability. Lesions were biopsied, and the depth of the cartilage lesion was assessed. Reliability was calculated using intraclass correlations. The interobserver reliability was 0.67 (95% confidence interval, 0.5-0.89) for the arthroscopic grading, and the intraobserver reliability with the video grading was 0.8 (95% confidence interval, 0.67-0.9). A high correlation was seen between the arthroscopic grading of depth and the histological grading of depth (0.91); on average, surgeons graded lesions using arthroscopy a mean of 0.37 (range, 0-0.86) deeper than the histological grade. The arthroscopic ICRS classification system has good interobserver and intraobserver reliability. A high correlation with histological assessment of depth provides evidence of validity for this classification system. As cartilage lesions are treated on the basis of the arthroscopic ICRS classification, it is important to ascertain the reliability and validity of this method. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Reliability Analysis of the MSC System
NASA Astrophysics Data System (ADS)
Kim, Young-Soo; Lee, Do-Kyoung; Lee, Chang-Ho; Woo, Sun-Hee
2003-09-01
MSC (Multi-Spectral Camera) is the payload of KOMPSAT-2, which is being developed for earth imaging in optical and near-infrared region. The design of the MSC is completed and its reliability has been assessed from part level to the MSC system level. The reliability was analyzed in worst case and the analysis results showed that the value complies the required value of 0.9. In this paper, a calculation method of reliability for the MSC system is described, and assessment result is presented and discussed.
Bulk electric system reliability evaluation incorporating wind power and demand side management
NASA Astrophysics Data System (ADS)
Huang, Dange
Electric power systems are experiencing dramatic changes with respect to structure, operation and regulation and are facing increasing pressure due to environmental and societal constraints. Bulk electric system reliability is an important consideration in power system planning, design and operation particularly in the new competitive environment. A wide range of methods have been developed to perform bulk electric system reliability evaluation. Theoretically, sequential Monte Carlo simulation can include all aspects and contingencies in a power system and can be used to produce an informative set of reliability indices. It has become a practical and viable tool for large system reliability assessment technique due to the development of computing power and is used in the studies described in this thesis. The well-being approach used in this research provides the opportunity to integrate an accepted deterministic criterion into a probabilistic framework. This research work includes the investigation of important factors that impact bulk electric system adequacy evaluation and security constrained adequacy assessment using the well-being analysis framework. Load forecast uncertainty is an important consideration in an electrical power system. This research includes load forecast uncertainty considerations in bulk electric system reliability assessment and the effects on system, load point and well-being indices and reliability index probability distributions are examined. There has been increasing worldwide interest in the utilization of wind power as a renewable energy source over the last two decades due to enhanced public awareness of the environment. Increasing penetration of wind power has significant impacts on power system reliability, and security analyses become more uncertain due to the unpredictable nature of wind power. The effects of wind power additions in generating and bulk electric system reliability assessment considering site wind speed correlations and the interactive effects of wind power and load forecast uncertainty on system reliability are examined. The concept of the security cost associated with operating in the marginal state in the well-being framework is incorporated in the economic analyses associated with system expansion planning including wind power and load forecast uncertainty. Overall reliability cost/worth analyses including security cost concepts are applied to select an optimal wind power injection strategy in a bulk electric system. The effects of the various demand side management measures on system reliability are illustrated using the system, load point, and well-being indices, and the reliability index probability distributions. The reliability effects of demand side management procedures in a bulk electric system including wind power and load forecast uncertainty considerations are also investigated. The system reliability effects due to specific demand side management programs are quantified and examined in terms of their reliability benefits.
Jackson, Brian A; Faith, Kay Sullivan
2013-02-01
Although significant progress has been made in measuring public health emergency preparedness, system-level performance measures are lacking. This report examines a potential approach to such measures for Strategic National Stockpile (SNS) operations. We adapted an engineering analytic technique used to assess the reliability of technological systems-failure mode and effects analysis-to assess preparedness. That technique, which includes systematic mapping of the response system and identification of possible breakdowns that affect performance, provides a path to use data from existing SNS assessment tools to estimate likely future performance of the system overall. Systems models of SNS operations were constructed and failure mode analyses were performed for each component. Linking data from existing assessments, including the technical assistance review and functional drills, to reliability assessment was demonstrated using publicly available information. The use of failure mode and effects estimates to assess overall response system reliability was demonstrated with a simple simulation example. Reliability analysis appears an attractive way to integrate information from the substantial investment in detailed assessments for stockpile delivery and dispensing to provide a view of likely future response performance.
Reliability Assessment of Reconfigurable Flight Control Systems Using Sure and Assist
NASA Technical Reports Server (NTRS)
Wu, N. Eva
1992-01-01
This paper presents a reliability assessment of Reconfigurable Flight Control Systems using Semi-Markov Unreliability Range Evaluator (SURE) and Abstract Semi-Markov Specification Interface to the SURE Tool (ASSIST).
Flight control electronics reliability/maintenance study
NASA Technical Reports Server (NTRS)
Dade, W. W.; Edwards, R. H.; Katt, G. T.; Mcclellan, K. L.; Shomber, H. A.
1977-01-01
Collection and analysis of data are reported that concern the reliability and maintenance experience of flight control system electronics currently in use on passenger carrying jet aircraft. Two airlines B-747 airplane fleets were analyzed to assess the component reliability, system functional reliability, and achieved availability of the CAT II configuration flight control system. Also assessed were the costs generated by this system in the categories of spare equipment, schedule irregularity, and line and shop maintenance. The results indicate that although there is a marked difference in the geographic location and route pattern between the airlines studied, there is a close similarity in the reliability and the maintenance costs associated with the flight control electronics.
Soleymani, Zahra; Joveini, Ghodsiye; Baghestani, Ahmad Reza
2015-03-01
This study developed a Farsi language Communication Function Classification System and then tested its reliability and validity. Communication Function Classification System is designed to classify the communication functions of individuals with cerebral palsy. Up until now, there has been no instrument for assessment of this communication function in Iran. The English Communication Function Classification System was translated into Farsi and cross-culturally modified by a panel of experts. Professionals and parents then assessed the content validity of the modified version. A backtranslation of the Farsi version was confirmed by the developer of the English Communication Function Classification System. Face validity was assessed by therapists and parents of 10 patients. The Farsi Communication Function Classification System was administered to 152 individuals with cerebral palsy (age, 2 to 18 years; median age, 10 years; mean age, 9.9 years; standard deviation, 4.3 years). Inter-rater reliability was analyzed between parents, occupational therapists, and speech and language pathologists. The test-retest reliability was assessed for 75 patients with a 14 day interval between tests. The inter-rater reliability of the Communication Function Classification System was 0.81 between speech and language pathologists and occupational therapists, 0.74 between parents and occupational therapists, and 0.88 between parents and speech and language pathologists. The test-retest reliability was 0.96 for occupational therapists, 0.98 for speech and language pathologists, and 0.94 for parents. The findings suggest that the Farsi version of Communication Function Classification System is a reliable and valid measure that can be used in clinical settings to assess communication function in patients with cerebral palsy. Copyright © 2015 Elsevier Inc. All rights reserved.
Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A
2015-05-01
Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
The Reliability and Structure of the Classroom Assessment Scoring System in German Pre-Schools
ERIC Educational Resources Information Center
Stuck, Andrea; Kammermeyer, Gisela; Roux, Susanna
2016-01-01
This study examined the reliability and structure of the Classroom Assessment Scoring System (CLASS; Pianta, R. C., K. M. La Paro, and B. K. Hamre. 2008. "Classroom Assessment Scoring System. Manual Pre-K." Baltimore, MD: Brookes) and the quality of interactional processes in a German pre-school setting, drawing on a sample of 390…
Training and Maintaining System-Wide Reliability in Outcome Management.
Barwick, Melanie A; Urajnik, Diana J; Moore, Julia E
2014-01-01
The Child and Adolescent Functional Assessment Scale (CAFAS) is widely used for outcome management, for providing real time client and program level data, and the monitoring of evidence-based practices. Methods of reliability training and the assessment of rater drift are critical for service decision-making within organizations and systems of care. We assessed two approaches for CAFAS training: external technical assistance and internal technical assistance. To this end, we sampled 315 practitioners trained by external technical assistance approach from 2,344 Ontario practitioners who had achieved reliability on the CAFAS. To assess the internal technical assistance approach as a reliable alternative training method, 140 practitioners trained internally were selected from the same pool of certified raters. Reliabilities were high for both practitioners trained by external technical assistance and internal technical assistance approaches (.909-.995, .915-.997, respectively). 1 and 3-year estimates showed some drift on several scales. High and consistent reliabilities over time and training method has implications for CAFAS training of behavioral health care practitioners, and the maintenance of CAFAS as a global outcome management tool in systems of care.
2011-11-01
assessment to quality of localization/characterization estimates. This protocol includes four critical components: (1) a procedure to identify the...critical factors impacting SHM system performance; (2) a multistage or hierarchical approach to SHM system validation; (3) a model -assisted evaluation...Lindgren, E. A ., Buynak, C. F., Steffes, G., Derriso, M., “ Model -assisted Probabilistic Reliability Assessment for Structural Health Monitoring
Reliability of intracerebral hemorrhage classification systems: A systematic review.
Rannikmäe, Kristiina; Woodfield, Rebecca; Anderson, Craig S; Charidimou, Andreas; Chiewvit, Pipat; Greenberg, Steven M; Jeng, Jiann-Shing; Meretoja, Atte; Palm, Frederic; Putaala, Jukka; Rinkel, Gabriel Je; Rosand, Jonathan; Rost, Natalia S; Strbian, Daniel; Tatlisumak, Turgut; Tsai, Chung-Fen; Wermer, Marieke Jh; Werring, David; Yeh, Shin-Joe; Al-Shahi Salman, Rustam; Sudlow, Cathie Lm
2016-08-01
Accurately distinguishing non-traumatic intracerebral hemorrhage (ICH) subtypes is important since they may have different risk factors, causal pathways, management, and prognosis. We systematically assessed the inter- and intra-rater reliability of ICH classification systems. We sought all available reliability assessments of anatomical and mechanistic ICH classification systems from electronic databases and personal contacts until October 2014. We assessed included studies' characteristics, reporting quality and potential for bias; summarized reliability with kappa value forest plots; and performed meta-analyses of the proportion of cases classified into each subtype. We included 8 of 2152 studies identified. Inter- and intra-rater reliabilities were substantial to perfect for anatomical and mechanistic systems (inter-rater kappa values: anatomical 0.78-0.97 [six studies, 518 cases], mechanistic 0.89-0.93 [three studies, 510 cases]; intra-rater kappas: anatomical 0.80-1 [three studies, 137 cases], mechanistic 0.92-0.93 [two studies, 368 cases]). Reporting quality varied but no study fulfilled all criteria and none was free from potential bias. All reliability studies were performed with experienced raters in specialist centers. Proportions of ICH subtypes were largely consistent with previous reports suggesting that included studies are appropriately representative. Reliability of existing classification systems appears excellent but is unknown outside specialist centers with experienced raters. Future reliability comparisons should be facilitated by studies following recently published reporting guidelines. © 2016 World Stroke Organization.
Watson, C J; Propps, M; Galt, W; Redding, A; Dobbs, D
1999-07-01
Test-retest reliability study with blinded testers. To determine the intratester reliability of the McConnell classification system and to determine whether the intertester reliability of this system would be improved by one-on-one training of the testers, increasing the variability and numbers of subjects, blinding the testers to the absence or presence of patellofemoral pain syndrome, and adhering to the McConnell classification system as it is taught in the "McConnell Patellofemoral Treatment Plan" continuing education course. The McConnell classification system is currently used by physical therapy clinicians to quantify static patellar orientation. The measurements generated from this system purportedly guide the therapist in the application of patellofemoral tape and in assessment of the efficacy of treatment interventions on changing patellar orientation. Fifty-six subjects (age range, 21-65 years) provided a total of 101 knees for assessment. Seventy-six knees did not produce symptoms. A researcher who did not participate in the measuring process determined that 17 subjects had patellofemoral pain syndrome in 25 knees. Two testers concurrently measured static patellar orientation (anterior/posterior and medial/lateral tilt, medial/lateral glide, and patellar rotation) on subjects, using the McConnell classification system. Repeat measures were performed 3-7 days later. A kappa (kappa) statistic was used to assess the degree of agreement within each tester and between testers. The kappa coefficients for intratester reliability varied from -0.06 to 0.35. Intertester reliability ranged from -0.03 to 0.19. The McConnell classification system, in its current form, does not appear to be very reliable. Intratester reliability ranged from poor to fair, and intertester reliability was poor to slight. This system should not be used as a measurement tool or as a basis for treatment decisions.
The 747 primary flight control systems reliability and maintenance study
NASA Technical Reports Server (NTRS)
1979-01-01
The major operational characteristics of the 747 Primary Flight Control Systems (PFCS) are described. Results of reliability analysis for separate control functions are presented. The analysis makes use of a NASA computer program which calculates reliability of redundant systems. Costs for maintaining the 747 PFCS in airline service are assessed. The reliabilities and cost will provide a baseline for use in trade studies of future flight control system design.
Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly
Maier, Andrea B.; Aarts, Ronald G. K. M.; van Gerven, Joop M. A.; Arendzen, J. Hans; Schouten, Alfred C.; Meskers, Carel G. M.; van der Kooij, Herman
2016-01-01
Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system identification techniques. Methods In twelve healthy elderly balance tests were performed twice a day during three days. Body sway was measured during two minutes of standing with eyes closed and the Balance test Room (BalRoom) was used to apply four disturbances simultaneously: two sensory disturbances, to the proprioceptive and the visual system, and two mechanical disturbances applied at the leg and trunk segment. Using system identification techniques, sensitivity functions of the sensory disturbances and the neuromuscular controller were estimated. Based on the generalizability theory (G theory), systematic errors and sources of variability were assessed using linear mixed models and reliability was assessed by computing indexes of dependability (ID), standard error of measurement (SEM) and minimal detectable change (MDC). Results A systematic error was found between the first and second trial in the sensitivity functions. No systematic error was found in the neuromuscular controller and body sway. The reliability of 15 of 25 parameters and body sway were moderate to excellent when the results of two trials on three days were averaged. To reach an excellent reliability on one day in 7 out of 25 parameters, it was predicted that at least seven trials must be averaged. Conclusion This study shows that system identification techniques are a promising method to assess the underlying systems involved in standing balance in elderly. However, most of the parameters do not appear to be reliable unless a large number of trials are collected across multiple days. To reach an excellent reliability in one third of the parameters, a training session for participants is needed and at least seven trials of two minutes must be performed on one day. PMID:26953694
ERIC Educational Resources Information Center
Pantzare, Anna Lind
2015-01-01
In most large-scale assessment systems a set of rather expensive external quality controls are implemented in order to guarantee the quality of interrater reliability. This study empirically examines if teachers' ratings of national tests in mathematics can be reliable without using monitoring, training, or other methods of external quality…
Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan
2016-01-01
The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.
Towards early software reliability prediction for computer forensic tools (case study).
Abu Talib, Manar
2016-01-01
Versatility, flexibility and robustness are essential requirements for software forensic tools. Researchers and practitioners need to put more effort into assessing this type of tool. A Markov model is a robust means for analyzing and anticipating the functioning of an advanced component based system. It is used, for instance, to analyze the reliability of the state machines of real time reactive systems. This research extends the architecture-based software reliability prediction model for computer forensic tools, which is based on Markov chains and COSMIC-FFP. Basically, every part of the computer forensic tool is linked to a discrete time Markov chain. If this can be done, then a probabilistic analysis by Markov chains can be performed to analyze the reliability of the components and of the whole tool. The purposes of the proposed reliability assessment method are to evaluate the tool's reliability in the early phases of its development, to improve the reliability assessment process for large computer forensic tools over time, and to compare alternative tool designs. The reliability analysis can assist designers in choosing the most reliable topology for the components, which can maximize the reliability of the tool and meet the expected reliability level specified by the end-user. The approach of assessing component-based tool reliability in the COSMIC-FFP context is illustrated with the Forensic Toolkit Imager case study.
Reliability and Probabilistic Risk Assessment - How They Play Together
NASA Technical Reports Server (NTRS)
Safie, Fayssal; Stutts, Richard; Huang, Zhaofeng
2015-01-01
Since the Space Shuttle Challenger accident in 1986, NASA has extensively used probabilistic analysis methods to assess, understand, and communicate the risk of space launch vehicles. Probabilistic Risk Assessment (PRA), used in the nuclear industry, is one of the probabilistic analysis methods NASA utilizes to assess Loss of Mission (LOM) and Loss of Crew (LOC) risk for launch vehicles. PRA is a system scenario based risk assessment that uses a combination of fault trees, event trees, event sequence diagrams, and probability distributions to analyze the risk of a system, a process, or an activity. It is a process designed to answer three basic questions: 1) what can go wrong that would lead to loss or degraded performance (i.e., scenarios involving undesired consequences of interest), 2) how likely is it (probabilities), and 3) what is the severity of the degradation (consequences). Since the Challenger accident, PRA has been used in supporting decisions regarding safety upgrades for launch vehicles. Another area that was given a lot of emphasis at NASA after the Challenger accident is reliability engineering. Reliability engineering has been a critical design function at NASA since the early Apollo days. However, after the Challenger accident, quantitative reliability analysis and reliability predictions were given more scrutiny because of their importance in understanding failure mechanism and quantifying the probability of failure, which are key elements in resolving technical issues, performing design trades, and implementing design improvements. Although PRA and reliability are both probabilistic in nature and, in some cases, use the same tools, they are two different activities. Specifically, reliability engineering is a broad design discipline that deals with loss of function and helps understand failure mechanism and improve component and system design. PRA is a system scenario based risk assessment process intended to assess the risk scenarios that could lead to a major/top undesirable system event, and to identify those scenarios that are high-risk drivers. PRA output is critical to support risk informed decisions concerning system design. This paper describes the PRA process and the reliability engineering discipline in detail. It discusses their differences and similarities and how they work together as complementary analyses to support the design and risk assessment processes. Lessons learned, applications, and case studies in both areas are also discussed in the paper to demonstrate and explain these differences and similarities.
Methodology for Software Reliability Prediction. Volume 1.
1987-11-01
SPACECRAFT 0 MANNED SPACECRAFT B ATCH SYSTEM AIRBORNE AVIONICS 0 UNMANNED EVENT C014TROL a REAL TIME CLOSED 0 UNMANNED SPACECRAFT LOOP OPERATINS SPACECRAFT...software reliability. A Software Reliability Measurement Framework was established which spans the life cycle of a software system and includes the...specification, prediction, estimation, and assessment of software reliability. Data from 59 systems , representing over 5 million lines of code, were
Integrating Formal Methods and Testing 2002
NASA Technical Reports Server (NTRS)
Cukic, Bojan
2002-01-01
Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.
A Passive System Reliability Analysis for a Station Blackout
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brunett, Acacia; Bucknor, Matthew; Grabaskas, David
2015-05-03
The latest iterations of advanced reactor designs have included increased reliance on passive safety systems to maintain plant integrity during unplanned sequences. While these systems are advantageous in reducing the reliance on human intervention and availability of power, the phenomenological foundations on which these systems are built require a novel approach to a reliability assessment. Passive systems possess the unique ability to fail functionally without failing physically, a result of their explicit dependency on existing boundary conditions that drive their operating mode and capacity. Argonne National Laboratory is performing ongoing analyses that demonstrate various methodologies for the characterization of passivemore » system reliability within a probabilistic framework. Two reliability analysis techniques are utilized in this work. The first approach, the Reliability Method for Passive Systems, provides a mechanistic technique employing deterministic models and conventional static event trees. The second approach, a simulation-based technique, utilizes discrete dynamic event trees to treat time- dependent phenomena during scenario evolution. For this demonstration analysis, both reliability assessment techniques are used to analyze an extended station blackout in a pool-type sodium fast reactor (SFR) coupled with a reactor cavity cooling system (RCCS). This work demonstrates the entire process of a passive system reliability analysis, including identification of important parameters and failure metrics, treatment of uncertainties and analysis of results.« less
Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis
NASA Astrophysics Data System (ADS)
Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang
2017-07-01
In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.
Structural reliability assessment capability in NESSUS
NASA Technical Reports Server (NTRS)
Millwater, H.; Wu, Y.-T.
1992-01-01
The principal capabilities of NESSUS (Numerical Evaluation of Stochastic Structures Under Stress), an advanced computer code developed for probabilistic structural response analysis, are reviewed, and its structural reliability assessed. The code combines flexible structural modeling tools with advanced probabilistic algorithms in order to compute probabilistic structural response and resistance, component reliability and risk, and system reliability and risk. An illustrative numerical example is presented.
Structural reliability assessment capability in NESSUS
NASA Astrophysics Data System (ADS)
Millwater, H.; Wu, Y.-T.
1992-07-01
The principal capabilities of NESSUS (Numerical Evaluation of Stochastic Structures Under Stress), an advanced computer code developed for probabilistic structural response analysis, are reviewed, and its structural reliability assessed. The code combines flexible structural modeling tools with advanced probabilistic algorithms in order to compute probabilistic structural response and resistance, component reliability and risk, and system reliability and risk. An illustrative numerical example is presented.
Parhar, Harman S; Thamboo, Andrew; Habib, Al-Rahim; Chang, Brent; Gan, Eng Cern; Javer, Amin R
2014-04-01
The Philpott-Javer postoperative endoscopic mucosal staging system for allergic fungal rhinosinusitis has previously demonstrated acceptable interrater reliability among rhinologists. There are, however, numerous learners involved in patient care at tertiary centers. This study aims to analyze the interrater and intrarater reliability of this system among learners in otolaryngology at different stages in training. A prospective analysis of retrospectively collected endoscopic photographs. A tertiary care teaching hospital (January 2013). Fifty patients undergoing routine follow-up. Three photographs from each of 50 patients undergoing routine postsurgical nasoendoscopy were reviewed. Images were played twice, 1 week apart, in 2 differently randomized cycles and scored according to Philpott-Javer criteria by a rhinologist, a rhinology fellow, a senior otolaryngology resident, a junior otolaryngology resident, and a medical student. Interobserver reliability was assessed using the intraclass correlation coefficient, while intrarater reliability was assessed by Shrout-Fleiss κ values. Agreement between each learner and the rhinologist was also assessed using κ values. The interclass correlation among the 5 raters was 0.7600 (95% confidence interval, 0.6917-0.8161) for the Philpott-Javer scoring system, suggesting substantial reliability. Intrarater data showed substantial to almost-perfect reliability (κ values between 0.668 and 0.815) among all raters using this system. There was also moderate to substantial agreement between the learners and the rhinologist (κ values between 0.534 and 0.710). Results suggest that the Philpott-Javer staging system has acceptable intrarater and interrater reliability among learners of differing levels of clinical experience and is suitable for evaluating progress following surgery.
Validation and Improvement of Reliability Methods for Air Force Building Systems
focusing primarily on HVAC systems . This research used contingency analysis to assess the performance of each model for HVAC systems at six Air Force...probabilistic model produced inflated reliability calculations for HVAC systems . In light of these findings, this research employed a stochastic method, a...Nonhomogeneous Poisson Process (NHPP), in an attempt to produce accurate HVAC system reliability calculations. This effort ultimately concluded that
Reliability and Maintainability Data for Lead Lithium Cooling Systems
Cadwallader, Lee
2016-11-16
This article presents component failure rate data for use in assessment of lead lithium cooling systems. Best estimate data applicable to this liquid metal coolant is presented. Repair times for similar components are also referenced in this work. These data support probabilistic safety assessment and reliability, availability, maintainability and inspectability analyses.
Feasibility of a Semi-computerized Line Bisection Test for Unilateral Visual Neglect Assessment.
Jee, H; Kim, J; Kim, C; Kim, T; Park, J
2015-01-01
Commonly used paper-and-pencil based test modalities for assessing the degree of unilateral visual neglect (ULN) in patients with hemispheric cerebral lesions consume human resources with a significant inter and intra-rater variability. To explore the feasibility of a semi-computerized electronic-pen based ULN assessment system (e-system) to improve assessment quality without altering the conventional user interface. Thirty cognitively healthy participants (HG) and 11 participants diagnosed with right-hemispheric lesion and unilateral visual neglect (NG) were recruited to evaluate the e-system. Line bisection tests (LBT) were repeatedly conducted twice for the inter-rater and intra-rater (reliability) comparisons. The LBT results were assessed by the e-system and the golden standard methods (manual rater assessment). The percent deviation (%), assessment duration (sec), and number of neglected line (each) were evaluated. The inter-rater comparisons of the assessed deviation (%) variable showed excellent interrater reliabilities (CCCs) ranging from .84 (.59 to .95 (p < .001)) to .99 (.90 to .99 (p < .001)) for HG and NG. The Bland Altman mean difference (B-A) plots with bias (95% LOA (limits of agreement)) showed similar agreements between the e-system and the raters ranging from -.04 % (-2.10 to 1.97) to 1.30 % (-2.23 to 4.84) for HG and NG. The effect sizes (ES), which show similarities between the assessment methods, yielded smaller ranges from .01 to .30 for HG and NG. The reliability (test-retest) comparisons showed similar assessment results between the e-system, rater 1, and rater 2. The manual rater assessment time ranging from 5.85 to 6.00 minutes and inter- and intraassessment variations were virtually eliminated with the e-system. The semi-computerized system with the conventional paper-and pencil user-interface showed valid and reliable assessment results. It may be a feasible replacement for the manual rater assessment modality even in a clinical setting.
Reliability and Validity of Finger Strength and Endurance Measurements in Rock Climbing
ERIC Educational Resources Information Center
Michailov, Michail Lubomirov; Baláš, Jirí; Tanev, Stoyan Kolev; Andonov, Hristo Stoyanov; Kodejška, Jan; Brown, Lee
2018-01-01
Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the…
Reliability of in-Shoe Plantar Pressure Measurements in Rheumatoid Arthritis Patients
ERIC Educational Resources Information Center
Vidmar, Gaj; Novak, Primoz
2009-01-01
Plantar pressures measurement is a frequently used method in rehabilitation and related research. Metric characteristics of the F-Scan system have been assessed from different standpoints and in different patients, but not its reliability in rheumatoid arthritis patients. Therefore, our objective was to assess reliability of the F-Scan plantar…
Koontz, Alicia M; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L; Cooper, Rory A
2011-01-01
This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 nondisabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers.We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies.
NASA Astrophysics Data System (ADS)
Wallace, Jon Michael
2003-10-01
Reliability prediction of components operating in complex systems has historically been conducted in a statistically isolated manner. Current physics-based, i.e. mechanistic, component reliability approaches focus more on component-specific attributes and mathematical algorithms and not enough on the influence of the system. The result is that significant error can be introduced into the component reliability assessment process. The objective of this study is the development of a framework that infuses the needs and influence of the system into the process of conducting mechanistic-based component reliability assessments. The formulated framework consists of six primary steps. The first three steps, identification, decomposition, and synthesis, are primarily qualitative in nature and employ system reliability and safety engineering principles to construct an appropriate starting point for the component reliability assessment. The following two steps are the most unique. They involve a step to efficiently characterize and quantify the system-driven local parameter space and a subsequent step using this information to guide the reduction of the component parameter space. The local statistical space quantification step is accomplished using two proposed multivariate probability models: Multi-Response First Order Second Moment and Taylor-Based Inverse Transformation. Where existing joint probability models require preliminary distribution and correlation information of the responses, these models combine statistical information of the input parameters with an efficient sampling of the response analyses to produce the multi-response joint probability distribution. Parameter space reduction is accomplished using Approximate Canonical Correlation Analysis (ACCA) employed as a multi-response screening technique. The novelty of this approach is that each individual local parameter and even subsets of parameters representing entire contributing analyses can now be rank ordered with respect to their contribution to not just one response, but the entire vector of component responses simultaneously. The final step of the framework is the actual probabilistic assessment of the component. Although the same multivariate probability tools employed in the characterization step can be used for the component probability assessment, variations of this final step are given to allow for the utilization of existing probabilistic methods such as response surface Monte Carlo and Fast Probability Integration. The overall framework developed in this study is implemented to assess the finite-element based reliability prediction of a gas turbine airfoil involving several failure responses. Results of this implementation are compared to results generated using the conventional 'isolated' approach as well as a validation approach conducted through large sample Monte Carlo simulations. The framework resulted in a considerable improvement to the accuracy of the part reliability assessment and an improved understanding of the component failure behavior. Considerable statistical complexity in the form of joint non-normal behavior was found and accounted for using the framework. Future applications of the framework elements are discussed.
Advanced Reactor Passive System Reliability Demonstration Analysis for an External Event
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bucknor, Matthew D.; Grabaskas, David; Brunett, Acacia J.
2016-01-01
Many advanced reactor designs rely on passive systems to fulfill safety functions during accident sequences. These systems depend heavily on boundary conditions to induce a motive force, meaning the system can fail to operate as intended due to deviations in boundary conditions, rather than as the result of physical failures. Furthermore, passive systems may operate in intermediate or degraded modes. These factors make passive system operation difficult to characterize within a traditional probabilistic framework that only recognizes discrete operating modes and does not allow for the explicit consideration of time-dependent boundary conditions. Argonne National Laboratory has been examining various methodologiesmore » for assessing passive system reliability within a probabilistic risk assessment for a station blackout event at an advanced small modular reactor. This paper provides an overview of a passive system reliability demonstration analysis for an external event. Centering on an earthquake with the possibility of site flooding, the analysis focuses on the behavior of the passive reactor cavity cooling system following potential physical damage and system flooding. The assessment approach seeks to combine mechanistic and simulation-based methods to leverage the benefits of the simulation-based approach without the need to substantially deviate from conventional probabilistic risk assessment techniques. While this study is presented as only an example analysis, the results appear to demonstrate a high level of reliability for the reactor cavity cooling system (and the reactor system in general) to the postulated transient event.« less
Advanced Reactor Passive System Reliability Demonstration Analysis for an External Event
Bucknor, Matthew; Grabaskas, David; Brunett, Acacia J.; ...
2017-01-24
We report that many advanced reactor designs rely on passive systems to fulfill safety functions during accident sequences. These systems depend heavily on boundary conditions to induce a motive force, meaning the system can fail to operate as intended because of deviations in boundary conditions, rather than as the result of physical failures. Furthermore, passive systems may operate in intermediate or degraded modes. These factors make passive system operation difficult to characterize within a traditional probabilistic framework that only recognizes discrete operating modes and does not allow for the explicit consideration of time-dependent boundary conditions. Argonne National Laboratory has beenmore » examining various methodologies for assessing passive system reliability within a probabilistic risk assessment for a station blackout event at an advanced small modular reactor. This paper provides an overview of a passive system reliability demonstration analysis for an external event. Considering an earthquake with the possibility of site flooding, the analysis focuses on the behavior of the passive Reactor Cavity Cooling System following potential physical damage and system flooding. The assessment approach seeks to combine mechanistic and simulation-based methods to leverage the benefits of the simulation-based approach without the need to substantially deviate from conventional probabilistic risk assessment techniques. Lastly, although this study is presented as only an example analysis, the results appear to demonstrate a high level of reliability of the Reactor Cavity Cooling System (and the reactor system in general) for the postulated transient event.« less
Reliability Assessment for COTS Components in Space Flight Applications
NASA Technical Reports Server (NTRS)
Krishnan, G. S.; Mazzuchi, Thomas A.
2001-01-01
Systems built for space flight applications usually demand very high degree of performance and a very high level of accuracy. Hence, the design engineers are often prone to selecting state-of-art technologies for inclusion in their system design. The shrinking budgets also necessitate use of COTS (Commercial Off-The-Shelf) components, which are construed as being less expensive. The performance and accuracy requirements for space flight applications are much more stringent than those for the commercial applications. The quantity of systems designed and developed for space applications are much lower in number than those produced for the commercial applications. With a given set of requirements, are these COTS components reliable? This paper presents a model for assessing the reliability of COTS components in space applications and the associated affect on the system reliability. We illustrate the method with a real application.
Berger, Aaron J; Momeni, Arash; Ladd, Amy L
2014-04-01
Trapeziometacarpal, or thumb carpometacarpal (CMC), arthritis is a common problem with a variety of treatment options. Although widely used, the Eaton radiographic staging system for CMC arthritis is of questionable clinical utility, as disease severity does not predictably correlate with symptoms or treatment recommendations. A possible reason for this is that the classification itself may not be reliable, but the literature on this has not, to our knowledge, been systematically reviewed. We therefore performed a systematic review to determine the intra- and interobserver reliability of the Eaton staging system. We systematically reviewed English-language studies published between 1973 and 2013 to assess the degree of intra- and interobserver reliability of the Eaton classification for determining the stage of trapeziometacarpal joint arthritis and pantrapezial arthritis based on plain radiographic imaging. Search engines included: PubMed, Scopus(®), and CINAHL. Four studies, which included a total of 163 patients, met our inclusion criteria and were evaluated. The level of evidence of the studies included in this analysis was determined using the Oxford Centre for Evidence Based Medicine Levels of Evidence Classification by two independent observers. A limited number of studies have been performed to assess intra- and interobserver reliability of the Eaton classification system. The four studies included were determined to be Level 3b. These studies collectively indicate that the Eaton classification demonstrates poor to fair interobserver reliability (kappa values: 0.11-0.56) and fair to moderate intraobserver reliability (kappa values: 0.54-0.657). Review of the literature demonstrates that radiographs assist in the assessment of CMC joint disease, but there is not a reliable system for classification of disease severity. Currently, diagnosis and treatment of thumb CMC arthritis are based on the surgeon's qualitative assessment combining history, physical examination, and radiographic evaluation. Inconsistent agreement using the current common radiographic classification system suggests a need for better radiographic tools to quantify disease severity.
Koontz, Alicia M.; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L.; Cooper, Rory A.
2017-01-01
This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 non-disabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers. We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies. PMID:22068376
Systems Issues In Terrestrial Fiber Optic Link Reliability
NASA Astrophysics Data System (ADS)
Spencer, James L.; Lewin, Barry R.; Lee, T. Frank S.
1990-01-01
This paper reviews fiber optic system reliability issues from three different viewpoints - availability, operating environment, and evolving technologies. Present availability objectives for interoffice links and for the distribution loop must be re-examined for applications such as the Synchronous Optical Network (SONET), Fiber-to-the-Home (FTTH), and analog services. The hostile operating environments of emerging applications (such as FTTH) must be carefully considered in system design as well as reliability assessments. Finally, evolving technologies might require the development of new reliability testing strategies.
ERIC Educational Resources Information Center
Chang, Chi-Cheng; Liang, Chaoyun; Chen, Yi-Hui
2013-01-01
This study explored the reliability and validity of Web-based portfolio self-assessment. Participants were 72 senior high school students enrolled in a computer application course. The students created learning portfolios, viewed peers' work, and performed self-assessment on the Web-based portfolio assessment system. The results indicated: 1)…
NASA Astrophysics Data System (ADS)
Lin, Yi-Kuei; Huang, Cheng-Fu
2015-04-01
From a quality of service viewpoint, the transmission packet unreliability and transmission time are both critical performance indicators in a computer system when assessing the Internet quality for supervisors and customers. A computer system is usually modelled as a network topology where each branch denotes a transmission medium and each vertex represents a station of servers. Almost every branch has multiple capacities/states due to failure, partial failure, maintenance, etc. This type of network is known as a multi-state computer network (MSCN). This paper proposes an efficient algorithm that computes the system reliability, i.e., the probability that a specified amount of data can be sent through k (k ≥ 2) disjoint minimal paths within both the tolerable packet unreliability and time threshold. Furthermore, two routing schemes are established in advance to indicate the main and spare minimal paths to increase the system reliability (referred to as spare reliability). Thus, the spare reliability can be readily computed according to the routing scheme.
Reliability of Fault Tolerant Control Systems. Part 1
NASA Technical Reports Server (NTRS)
Wu, N. Eva
2001-01-01
This paper reports Part I of a two part effort, that is intended to delineate the relationship between reliability and fault tolerant control in a quantitative manner. Reliability analysis of fault-tolerant control systems is performed using Markov models. Reliability properties, peculiar to fault-tolerant control systems are emphasized. As a consequence, coverage of failures through redundancy management can be severely limited. It is shown that in the early life of a syi1ein composed of highly reliable subsystems, the reliability of the overall system is affine with respect to coverage, and inadequate coverage induces dominant single point failures. The utility of some existing software tools for assessing the reliability of fault tolerant control systems is also discussed. Coverage modeling is attempted in Part II in a way that captures its dependence on the control performance and on the diagnostic resolution.
Research on Novel Algorithms for Smart Grid Reliability Assessment and Economic Dispatch
NASA Astrophysics Data System (ADS)
Luo, Wenjin
In this dissertation, several studies of electric power system reliability and economy assessment methods are presented. To be more precise, several algorithms in evaluating power system reliability and economy are studied. Furthermore, two novel algorithms are applied to this field and their simulation results are compared with conventional results. As the electrical power system develops towards extra high voltage, remote distance, large capacity and regional networking, the application of a number of new technique equipments and the electric market system have be gradually established, and the results caused by power cut has become more and more serious. The electrical power system needs the highest possible reliability due to its complication and security. In this dissertation the Boolean logic Driven Markov Process (BDMP) method is studied and applied to evaluate power system reliability. This approach has several benefits. It allows complex dynamic models to be defined, while maintaining its easy readability as conventional methods. This method has been applied to evaluate IEEE reliability test system. The simulation results obtained are close to IEEE experimental data which means that it could be used for future study of the system reliability. Besides reliability, modern power system is expected to be more economic. This dissertation presents a novel evolutionary algorithm named as quantum evolutionary membrane algorithm (QEPS), which combines the concept and theory of quantum-inspired evolutionary algorithm and membrane computation, to solve the economic dispatch problem in renewable power system with on land and offshore wind farms. The case derived from real data is used for simulation tests. Another conventional evolutionary algorithm is also used to solve the same problem for comparison. The experimental results show that the proposed method is quick and accurate to obtain the optimal solution which is the minimum cost for electricity supplied by wind farm system.
Reliability and validity of the Microsoft Kinect for evaluating static foot posture
2013-01-01
Background The evaluation of foot posture in a clinical setting is useful to screen for potential injury, however disagreement remains as to which method has the greatest clinical utility. An inexpensive and widely available imaging system, the Microsoft Kinect™, may possess the characteristics to objectively evaluate static foot posture in a clinical setting with high accuracy. The aim of this study was to assess the intra-rater reliability and validity of this system for assessing static foot posture. Methods Three measures were used to assess static foot posture; traditional visual observation using the Foot Posture Index (FPI), a 3D motion analysis (3DMA) system and software designed to collect and analyse image and depth data from the Kinect. Spearman’s rho was used to assess intra-rater reliability and concurrent validity of the Kinect to evaluate foot posture, and a linear regression was used to examine the ability of the Kinect to predict total visual FPI score. Results The Kinect demonstrated moderate to good intra-rater reliability for four FPI items of foot posture (ρ = 0.62 to 0.78) and moderate to good correlations with the 3DMA system for four items of foot posture (ρ = 0.51 to 0.85). In contrast, intra-rater reliability of visual FPI items was poor to moderate (ρ = 0.17 to 0.63), and correlations with the Kinect and 3DMA systems were poor (absolute ρ = 0.01 to 0.44). Kinect FPI items with moderate to good reliability predicted 61% of the variance in total visual FPI score. Conclusions The majority of the foot posture items derived using the Kinect were more reliable than the traditional visual assessment of FPI, and were valid when compared to a 3DMA system. Individual foot posture items recorded using the Kinect were also shown to predict a moderate degree of variance in the total visual FPI score. Combined, these results support the future potential of the Kinect to accurately evaluate static foot posture in a clinical setting. PMID:23566934
Chen, J D; Sun, H L
1999-04-01
Objective. To assess and predict reliability of an equipment dynamically by making full use of various test informations in the development of products. Method. A new reliability growth assessment method based on army material system analysis activity (AMSAA) model was developed. The method is composed of the AMSAA model and test data conversion technology. Result. The assessment and prediction results of a space-borne equipment conform to its expectations. Conclusion. It is suggested that this method should be further researched and popularized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamachi La Commare, Kristina
Metrics for reliability, such as the frequency and duration of power interruptions, have been reported by electric utilities for many years. This study examines current utility practices for collecting and reporting electricity reliability information and discusses challenges that arise in assessing reliability because of differences among these practices. The study is based on reliability information for year 2006 reported by 123 utilities in 37 states representing over 60percent of total U.S. electricity sales. We quantify the effects that inconsistencies among current utility reporting practices have on comparisons of System Average Interruption Duration Index (SAIDI) and System Average Interruption Frequency Indexmore » (SAIFI) reported by utilities. We recommend immediate adoption of IEEE Std. 1366-2003 as a consistent method for measuring and reporting reliability statistics.« less
Prediction of Software Reliability using Bio Inspired Soft Computing Techniques.
Diwaker, Chander; Tomar, Pradeep; Poonia, Ramesh C; Singh, Vijander
2018-04-10
A lot of models have been made for predicting software reliability. The reliability models are restricted to using particular types of methodologies and restricted number of parameters. There are a number of techniques and methodologies that may be used for reliability prediction. There is need to focus on parameters consideration while estimating reliability. The reliability of a system may increase or decreases depending on the selection of different parameters used. Thus there is need to identify factors that heavily affecting the reliability of the system. In present days, reusability is mostly used in the various area of research. Reusability is the basis of Component-Based System (CBS). The cost, time and human skill can be saved using Component-Based Software Engineering (CBSE) concepts. CBSE metrics may be used to assess those techniques which are more suitable for estimating system reliability. Soft computing is used for small as well as large-scale problems where it is difficult to find accurate results due to uncertainty or randomness. Several possibilities are available to apply soft computing techniques in medicine related problems. Clinical science of medicine using fuzzy-logic, neural network methodology significantly while basic science of medicine using neural-networks-genetic algorithm most frequently and preferably. There is unavoidable interest shown by medical scientists to use the various soft computing methodologies in genetics, physiology, radiology, cardiology and neurology discipline. CBSE boost users to reuse the past and existing software for making new products to provide quality with a saving of time, memory space, and money. This paper focused on assessment of commonly used soft computing technique like Genetic Algorithm (GA), Neural-Network (NN), Fuzzy Logic, Support Vector Machine (SVM), Ant Colony Optimization (ACO), Particle Swarm Optimization (PSO), and Artificial Bee Colony (ABC). This paper presents working of soft computing techniques and assessment of soft computing techniques to predict reliability. The parameter considered while estimating and prediction of reliability are also discussed. This study can be used in estimation and prediction of the reliability of various instruments used in the medical system, software engineering, computer engineering and mechanical engineering also. These concepts can be applied to both software and hardware, to predict the reliability using CBSE.
Sensor Selection and Optimization for Health Assessment of Aerospace Systems
NASA Technical Reports Server (NTRS)
Maul, William A.; Kopasakis, George; Santi, Louis M.; Sowers, Thomas S.; Chicatelli, Amy
2007-01-01
Aerospace systems are developed similarly to other large-scale systems through a series of reviews, where designs are modified as system requirements are refined. For space-based systems few are built and placed into service. These research vehicles have limited historical experience to draw from and formidable reliability and safety requirements, due to the remote and severe environment of space. Aeronautical systems have similar reliability and safety requirements, and while these systems may have historical information to access, commercial and military systems require longevity under a range of operational conditions and applied loads. Historically, the design of aerospace systems, particularly the selection of sensors, is based on the requirements for control and performance rather than on health assessment needs. Furthermore, the safety and reliability requirements are met through sensor suite augmentation in an ad hoc, heuristic manner, rather than any systematic approach. A review of the current sensor selection practice within and outside of the aerospace community was conducted and a sensor selection architecture is proposed that will provide a justifiable, dependable sensor suite to address system health assessment requirements.
Sensor Selection and Optimization for Health Assessment of Aerospace Systems
NASA Technical Reports Server (NTRS)
Maul, William A.; Kopasakis, George; Santi, Louis M.; Sowers, Thomas S.; Chicatelli, Amy
2008-01-01
Aerospace systems are developed similarly to other large-scale systems through a series of reviews, where designs are modified as system requirements are refined. For space-based systems few are built and placed into service these research vehicles have limited historical experience to draw from and formidable reliability and safety requirements, due to the remote and severe environment of space. Aeronautical systems have similar reliability and safety requirements, and while these systems may have historical information to access, commercial and military systems require longevity under a range of operational conditions and applied loads. Historically, the design of aerospace systems, particularly the selection of sensors, is based on the requirements for control and performance rather than on health assessment needs. Furthermore, the safety and reliability requirements are met through sensor suite augmentation in an ad hoc, heuristic manner, rather than any systematic approach. A review of the current sensor selection practice within and outside of the aerospace community was conducted and a sensor selection architecture is proposed that will provide a justifiable, defendable sensor suite to address system health assessment requirements.
Alsalaheen, Bara; Haines, Jamie; Yorke, Amy; Broglio, Steven P
2015-12-01
To examine the reliability, convergent, and discriminant validity of the limits of stability (LOS) test to assess dynamic postural stability in adolescents using a portable forceplate system. Cross-sectional reliability observational study. School setting. Adolescents (N=36) completed all measures during the first session. To examine the reliability of the LOS test, a subset of 15 participants repeated the LOS test after 1 week. Not applicable. Outcome measurements included the LOS test, Balance Error Scoring System, Instrumented Balance Error Scoring System, and Modified Clinical Test for Sensory Interaction on Balance. A significant relation was observed among LOS composite scores (r=.36-.87, P<.05). However, no relation was observed between LOS and static balance outcome measurements. The reliability of the LOS composite scores ranged from moderate to good (intraclass correlation coefficient model 2,1=.73-.96). The results suggest that the LOS composite scores provide unique information about dynamic postural stability, and the LOS test completed at 100% of the theoretical limit appeared to be a reliable test of dynamic postural stability in adolescents. Clinicians should use dynamic balance measurement as part of their balance assessment and should not use static balance testing (eg, Balance Error Scoring System) to make inferences about dynamic balance, especially when balance assessment is used to determine rehabilitation outcomes, or when making return to play decisions after injury. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
An assessment of the real-time application capabilities of the SIFT computer system
NASA Technical Reports Server (NTRS)
Butler, R. W.
1982-01-01
The real-time capabilities of the SIFT computer system, a highly reliable multicomputer architecture developed to support the flight controls of a relaxed static stability aircraft, are discussed. The SIFT computer system was designed to meet extremely high reliability requirements and to facilitate a formal proof of its correctness. Although SIFT represents a significant achievement in fault-tolerant system research it presents an unusual and restrictive interface to its users. The characteristics of the user interface and its impact on application system design are assessed.
Reliability Impacts in Life Support Architecture and Technology Selection
NASA Technical Reports Server (NTRS)
Lange Kevin E.; Anderson, Molly S.
2012-01-01
Quantitative assessments of system reliability and equivalent system mass (ESM) were made for different life support architectures based primarily on International Space Station technologies. The analysis was applied to a one-year deep-space mission. System reliability was increased by adding redundancy and spares, which added to the ESM. Results were thus obtained allowing a comparison of the ESM for each architecture at equivalent levels of reliability. Although the analysis contains numerous simplifications and uncertainties, the results suggest that achieving necessary reliabilities for deep-space missions will add substantially to the life support ESM and could influence the optimal degree of life support closure. Approaches for reducing reliability impacts were investigated and are discussed.
Leddy, Abigail L; Crowner, Beth E; Earhart, Gammon M
2011-01-01
Gait impairments, balance impairments, and falls are prevalent in individuals with Parkinson disease (PD). Although the Berg Balance Scale (BBS) can be considered the reference standard for the determination of fall risk, it has a noted ceiling effect. Development of ceiling-free measures that can assess balance and are good at discriminating "fallers" from "nonfallers" is needed. The purpose of this study was to compare the Functional Gait Assessment (FGA) and the Balance Evaluation Systems Test (BESTest) with the BBS among individuals with PD and evaluate the tests' reliability, validity, and discriminatory sensitivity and specificity for fallers versus nonfallers. This was an observational study of community-dwelling individuals with idiopathic PD. The BBS, FGA, and BESTest were administered to 80 individuals with PD. Interrater reliability (n=15) was assessed by 3 raters. Test-retest reliability was based on 2 tests of participants (n=24), 2 weeks apart. Intraclass correlation coefficients (2,1) were used to calculate reliability, and Spearman correlation coefficients were used to assess validity. Cutoff points, sensitivity, and specificity were based on receiver operating characteristic plots. Test-retest reliability was .80 for the BBS, .91 for the FGA, and .88 for the BESTest. Interrater reliability was greater than .93 for all 3 tests. The FGA and BESTest were correlated with the BBS (r=.78 and r=.87, respectively). Cutoff scores to identify fallers were 47/56 for the BBS, 15/30 for the FGA, and 69% for the BESTest. The overall accuracy (area under the curve) for the BBS, FGA, and BESTest was .79, .80, and .85, respectively. Fall reports were retrospective. Both the FGA and the BESTest have reliability and validity for assessing balance in individuals with PD. The BESTest is most sensitive for identifying fallers.
Reliability and Probabilistic Risk Assessment - How They Play Together
NASA Technical Reports Server (NTRS)
Safie, Fayssal M.; Stutts, Richard G.; Zhaofeng, Huang
2015-01-01
PRA methodology is one of the probabilistic analysis methods that NASA brought from the nuclear industry to assess the risk of LOM, LOV and LOC for launch vehicles. PRA is a system scenario based risk assessment that uses a combination of fault trees, event trees, event sequence diagrams, and probability and statistical data to analyze the risk of a system, a process, or an activity. It is a process designed to answer three basic questions: What can go wrong? How likely is it? What is the severity of the degradation? Since 1986, NASA, along with industry partners, has conducted a number of PRA studies to predict the overall launch vehicles risks. Planning Research Corporation conducted the first of these studies in 1988. In 1995, Science Applications International Corporation (SAIC) conducted a comprehensive PRA study. In July 1996, NASA conducted a two-year study (October 1996 - September 1998) to develop a model that provided the overall Space Shuttle risk and estimates of risk changes due to proposed Space Shuttle upgrades. After the Columbia accident, NASA conducted a PRA on the Shuttle External Tank (ET) foam. This study was the most focused and extensive risk assessment that NASA has conducted in recent years. It used a dynamic, physics-based, integrated system analysis approach to understand the integrated system risk due to ET foam loss in flight. Most recently, a PRA for Ares I launch vehicle has been performed in support of the Constellation program. Reliability, on the other hand, addresses the loss of functions. In a broader sense, reliability engineering is a discipline that involves the application of engineering principles to the design and processing of products, both hardware and software, for meeting product reliability requirements or goals. It is a very broad design-support discipline. It has important interfaces with many other engineering disciplines. Reliability as a figure of merit (i.e. the metric) is the probability that an item will perform its intended function(s) for a specified mission profile. In general, the reliability metric can be calculated through the analyses using reliability demonstration and reliability prediction methodologies. Reliability analysis is very critical for understanding component failure mechanisms and in identifying reliability critical design and process drivers. The following sections discuss the PRA process and reliability engineering in detail and provide an application where reliability analysis and PRA were jointly used in a complementary manner to support a Space Shuttle flight risk assessment.
Evaluation of the Transit Reliability Information Program
DOT National Transportation Integrated Search
1982-06-01
This report presents an evaluation of the rail portion of the Transit Reliability Information Program (TRIP), which was designed to collect and analyze equipment reliability data on U.S. transit systems. This assessment was conducted at the end of it...
Estimates Of The Orbiter RSI Thermal Protection System Thermal Reliability
NASA Technical Reports Server (NTRS)
Kolodziej, P.; Rasky, D. J.
2002-01-01
In support of the Space Shuttle Orbiter post-flight inspection, structure temperatures are recorded at selected positions on the windward, leeward, starboard and port surfaces. Statistical analysis of this flight data and a non-dimensional load interference (NDLI) method are used to estimate the thermal reliability at positions were reusable surface insulation (RSI) is installed. In this analysis, structure temperatures that exceed the design limit define the critical failure mode. At thirty-three positions the RSI thermal reliability is greater than 0.999999 for the missions studied. This is not the overall system level reliability of the thermal protection system installed on an Orbiter. The results from two Orbiters, OV-102 and OV-105, are in good agreement. The original RSI designs on the OV-102 Orbital Maneuvering System pods, which had low reliability, were significantly improved on OV-105. The NDLI method was also used to estimate thermal reliability from an assessment of TPS uncertainties that was completed shortly before the first Orbiter flight. Results fiom the flight data analysis and the pre-flight assessment agree at several positions near each other. The NDLI method is also effective for optimizing RSI designs to provide uniform thermal reliability on the acreage surface of reusable launch vehicles.
Definition and trade-off study of reconfigurable airborne digital computer system organizations
NASA Technical Reports Server (NTRS)
Conn, R. B.
1974-01-01
A highly-reliable, fault-tolerant reconfigurable computer system for aircraft applications was developed. The development and application reliability and fault-tolerance assessment techniques are described. Particular emphasis is placed on the needs of an all-digital, fly-by-wire control system appropriate for a passenger-carrying airplane.
NASA Astrophysics Data System (ADS)
Bogachkov, I. V.; Lutchenko, S. S.
2018-05-01
The article deals with the method for the assessment of the fiber optic communication lines (FOCL) reliability taking into account the effect of the optical fiber tension, the temperature influence and the built-in diagnostic equipment errors of the first kind. The reliability is assessed in terms of the availability factor using the theory of Markov chains and probabilistic mathematical modeling. To obtain a mathematical model, the following steps are performed: the FOCL state is defined and validated; the state graph and system transitions are described; the system transition of states that occur at a certain point is specified; the real and the observed time of system presence in the considered states are identified. According to the permissible value of the availability factor, it is possible to determine the limiting frequency of FOCL maintenance.
Culture Representation in Human Reliability Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
David Gertman; Julie Marble; Steven Novack
Understanding human-system response is critical to being able to plan and predict mission success in the modern battlespace. Commonly, human reliability analysis has been used to predict failures of human performance in complex, critical systems. However, most human reliability methods fail to take culture into account. This paper takes an easily understood state of the art human reliability analysis method and extends that method to account for the influence of culture, including acceptance of new technology, upon performance. The cultural parameters used to modify the human reliability analysis were determined from two standard industry approaches to cultural assessment: Hofstede’s (1991)more » cultural factors and Davis’ (1989) technology acceptance model (TAM). The result is called the Culture Adjustment Method (CAM). An example is presented that (1) reviews human reliability assessment with and without cultural attributes for a Supervisory Control and Data Acquisition (SCADA) system attack, (2) demonstrates how country specific information can be used to increase the realism of HRA modeling, and (3) discusses the differences in human error probability estimates arising from cultural differences.« less
Bruyn, George A W; Hanova, Petra; Iagnocco, Annamaria; d'Agostino, Maria-Antonietta; Möller, Ingrid; Terslev, Lene; Backhaus, Marina; Balint, Peter V; Filippucci, Emilio; Baudoin, Paul; van Vugt, Richard; Pineda, Carlos; Wakefield, Richard; Garrido, Jesus; Pecha, Ondrej; Naredo, Esperanza
2014-11-01
To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
The development of a reliable amateur boxing performance analysis template.
Thomson, Edward; Lamb, Kevin; Nicholas, Ceri
2013-01-01
The aim of this study was to devise a valid performance analysis system for the assessment of the movement characteristics associated with competitive amateur boxing and assess its reliability using analysts of varying experience of the sport and performance analysis. Key performance indicators to characterise the demands of an amateur contest (offensive, defensive and feinting) were developed and notated using a computerised notational analysis system. Data were subjected to intra- and inter-observer reliability assessment using median sign tests and calculating the proportion of agreement within predetermined limits of error. For all performance indicators, intra-observer reliability revealed non-significant differences between observations (P > 0.05) and high agreement was established (80-100%) regardless of whether exact or the reference value of ±1 was applied. Inter-observer reliability was less impressive for both analysts (amateur boxer and experienced analyst), with the proportion of agreement ranging from 33-100%. Nonetheless, there was no systematic bias between observations for any indicator (P > 0.05), and the proportion of agreement within the reference range (±1) was 100%. A reliable performance analysis template has been developed for the assessment of amateur boxing performance and is available for use by researchers, coaches and athletes to classify and quantify the movement characteristics of amateur boxing.
Quality assurance and reliability sub-committee W88-0/Mk5 weapon assessment NSA lab test results (u)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitney, Earl M
2010-11-29
The purpose of this report is to gather appropriate level of relevant stockpile surveillance data to assess trends in the NEP quality, reliability, performance, and safety over the life of the system. The objectives are to gather relevant stockpile data to assess NEP quality and trends and to develop metrics to assess the suitability of the surveillance sampling regime to meet assessment process requirements.
Applying Resource Utilization Groups (RUG-III) in Hong Kong nursing homes.
Chou, Kee-Lee; Chi, Iris; Leung, Joe C B
2008-01-01
Resource Utilization Groups III (RUG-III) is a case-mix system developed in the United States for categorization of nursing home residents and the financing of residential care services. In Hong Kong, RUG-III is based on several board groups of residents. The aim of this study was to examine the reliability and validity of the RUG-III in Hong Kong nursing homes. A cross-sectional survey was conducted in seven residential facilities operated by one agency. Residents ( N = 1,127) were assessed by the Minimum Data Set (MDS) and nursing as well as auxiliary staff care times were recorded within 2 weeks before or after the completion of MDS assessment. Forty-five out 1,127 residents were re-interviewed by an independent assessor to assess the inter-rater reliability. The inter-rater reliability of MDS assessment was excellent (kappa = 0.76) and the original RUG-III accounted for about 30 per cent of nursing staff time. Results provide preliminary evidence to support that RUG-III is a reliable and valid case-mix system for Hong Kong nursing homes, but future studies must be explored to reduce the variance of resource use explained by this case-mix system.
Lee, Myungmo; Song, Changho; Lee, Kyoungjin; Shin, Doochul; Shin, Seungho
2014-07-14
Treadmill gait analysis was more advantageous than over-ground walking because it allowed continuous measurements of the gait parameters. The purpose of this study was to investigate the concurrent validity and the test-retest reliability of the OPTOGait photoelectric cell system against the treadmill-based gait analysis system by assessing spatio-temporal gait parameters. Twenty-six stroke patients and 18 healthy adults were asked to walk on the treadmill at their preferred speed. The concurrent validity was assessed by comparing data obtained from the 2 systems, and the test-retest reliability was determined by comparing data obtained from the 1st and the 2nd session of the OPTOGait system. The concurrent validity, identified by the intra-class correlation coefficients (ICC [2, 1]), coefficients of variation (CVME), and 95% limits of agreement (LOA) for the spatial-temporal gait parameters, were excellent but the temporal parameters expressed as a percentage of the gait cycle were poor. The test-retest reliability of the OPTOGait System, identified by ICC (3, 1), CVME, 95% LOA, standard error of measurement (SEM), and minimum detectable change (MDC95%) for the spatio-temporal gait parameters, was high. These findings indicated that the treadmill-based OPTOGait System had strong concurrent validity and test-retest reliability. This portable system could be useful for clinical assessments.
Bayesian methods in reliability
NASA Astrophysics Data System (ADS)
Sander, P.; Badoux, R.
1991-11-01
The present proceedings from a course on Bayesian methods in reliability encompasses Bayesian statistical methods and their computational implementation, models for analyzing censored data from nonrepairable systems, the traits of repairable systems and growth models, the use of expert judgment, and a review of the problem of forecasting software reliability. Specific issues addressed include the use of Bayesian methods to estimate the leak rate of a gas pipeline, approximate analyses under great prior uncertainty, reliability estimation techniques, and a nonhomogeneous Poisson process. Also addressed are the calibration sets and seed variables of expert judgment systems for risk assessment, experimental illustrations of the use of expert judgment for reliability testing, and analyses of the predictive quality of software-reliability growth models such as the Weibull order statistics.
Approach to developing reliable space reactor power systems
NASA Technical Reports Server (NTRS)
Mondt, Jack F.; Shinbrot, Charles H.
1991-01-01
During Phase II, the Engineering Development Phase, the SP-100 Project has defined and is pursuing a new approach to developing reliable power systems. The approach to developing such a system during the early technology phase is described along with some preliminary examples to help explain the approach. Developing reliable components to meet space reactor power system requirements is based on a top-down systems approach which includes a point design based on a detailed technical specification of a 100-kW power system. The SP-100 system requirements implicitly recognize the challenge of achieving a high system reliability for a ten-year lifetime, while at the same time using technologies that require very significant development efforts. A low-cost method for assessing reliability, based on an understanding of fundamental failure mechanisms and design margins for specific failure mechanisms, is being developed as part of the SP-100 Program.
Systematic review of methods for quantifying teamwork in the operating theatre
Marshall, D.; Sykes, M.; McCulloch, P.; Shalhoub, J.; Maruthappu, M.
2018-01-01
Background Teamwork in the operating theatre is becoming increasingly recognized as a major factor in clinical outcomes. Many tools have been developed to measure teamwork. Most fall into two categories: self‐assessment by theatre staff and assessment by observers. A critical and comparative analysis of the validity and reliability of these tools is lacking. Methods MEDLINE and Embase databases were searched following PRISMA guidelines. Content validity was assessed using measurements of inter‐rater agreement, predictive validity and multisite reliability, and interobserver reliability using statistical measures of inter‐rater agreement and reliability. Quantitative meta‐analysis was deemed unsuitable. Results Forty‐eight articles were selected for final inclusion; self‐assessment tools were used in 18 and observational tools in 28, and there were two qualitative studies. Self‐assessment of teamwork by profession varied with the profession of the assessor. The most robust self‐assessment tool was the Safety Attitudes Questionnaire (SAQ), although this failed to demonstrate multisite reliability. The most robust observational tool was the Non‐Technical Skills (NOTECHS) system, which demonstrated both test–retest reliability (P > 0·09) and interobserver reliability (Rwg = 0·96). Conclusion Self‐assessment of teamwork by the theatre team was influenced by professional differences. Observational tools, when used by trained observers, circumvented this.
Llorens, Roberto; Latorre, Jorge; Noé, Enrique; Keshner, Emily A
2016-01-01
Posturography systems that incorporate force platforms are considered to assess balance and postural control with greater sensitivity and objectivity than conventional clinical tests. The Wii Balance Board (WBB) system has been shown to have similar performance characteristics as other force platforms, but with lower cost and size. To determine the validity and reliability of a freely available WBB-based posturography system that combined the WBB with several traditional balance assessments, and to assess the performance of a cohort of stroke individuals with respect to healthy individuals. Healthy subjects and individuals with stroke were recruited. Both groups were assessed using the WBB-based posturography system. Individuals with stroke were also assessed using a laboratory grade posturography system and a battery of clinical tests to determine the concurrent validity of the system. A group of subjects were assessed twice with the WBB-based system to determine its reliability. A total of 144 healthy individuals and 53 individuals with stroke participated in the study. Concurrent validity with another posturography system was moderate to high. Correlations with clinical scales were consistent with previous research. The reliability of the system was excellent in almost all measures. In addition, the system successfully characterized individuals with stroke with respect to the healthy population. The WBB-based posturography system exhibited excellent psychometric properties and sensitivity for identifying balance performance of individuals with stroke in comparison with healthy subjects, which supports feasibility of the system as a clinical tool. Copyright © 2015 Elsevier B.V. All rights reserved.
Assessing Peer Entry and Play in Preschoolers at Risk for Maladjustment
ERIC Educational Resources Information Center
Brotman, Laurie Miller; Gouley, Kathleen Kiely; Chesir-Teran, Daniel
2005-01-01
This study evaluated the psychometric properties of an observational rating system for assessing preschoolers' peer entry and play skills: Observed Peer Play in Unfamiliar Settings (OPPUS). Participants were 84 preschoolers at risk for psychopathology. Reliability and concurrent validity are reported. The 30-min paradigm yielded reliable indexes…
The implementation and use of Ada on distributed systems with high reliability requirements
NASA Technical Reports Server (NTRS)
Knight, J. C.
1988-01-01
The use and implementation of Ada were investigated in distributed environments in which reliability is the primary concern. In particular, the focus was on the possibility that a distributed system may be programmed entirely in Ada so that the individual tasks of the system are unconcerned with which processors are being executed, and that failures may occur in the software and underlying hardware. A secondary interest is in the performance of Ada systems and how that performance can be gauged reliably. Primary activities included: analysis of the original approach to recovery in distributed Ada programs using the Advanced Transport Operating System (ATOPS) example; review and assessment of the original approach which was found to be capable of improvement; development of a refined approach to recovery that was applied to the ATOPS example; and design and development of a performance assessment scheme for Ada programs based on a flexible user-driven benchmarking system.
Design of fuel cell powered data centers for sufficient reliability and availability
NASA Astrophysics Data System (ADS)
Ritchie, Alexa J.; Brouwer, Jacob
2018-04-01
It is challenging to design a sufficiently reliable fuel cell electrical system for use in data centers, which require 99.9999% uptime. Such a system could lower emissions and increase data center efficiency, but the reliability and availability of such a system must be analyzed and understood. Currently, extensive backup equipment is used to ensure electricity availability. The proposed design alternative uses multiple fuel cell systems each supporting a small number of servers to eliminate backup power equipment provided the fuel cell design has sufficient reliability and availability. Potential system designs are explored for the entire data center and for individual fuel cells. Reliability block diagram analysis of the fuel cell systems was accomplished to understand the reliability of the systems without repair or redundant technologies. From this analysis, it was apparent that redundant components would be necessary. A program was written in MATLAB to show that the desired system reliability could be achieved by a combination of parallel components, regardless of the number of additional components needed. Having shown that the desired reliability was achievable through some combination of components, a dynamic programming analysis was undertaken to assess the ideal allocation of parallel components.
Reliability modeling of fault-tolerant computer based systems
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.
1987-01-01
Digital fault-tolerant computer-based systems have become commonplace in military and commercial avionics. These systems hold the promise of increased availability, reliability, and maintainability over conventional analog-based systems through the application of replicated digital computers arranged in fault-tolerant configurations. Three tightly coupled factors of paramount importance, ultimately determining the viability of these systems, are reliability, safety, and profitability. Reliability, the major driver affects virtually every aspect of design, packaging, and field operations, and eventually produces profit for commercial applications or increased national security. However, the utilization of digital computer systems makes the task of producing credible reliability assessment a formidable one for the reliability engineer. The root of the problem lies in the digital computer's unique adaptability to changing requirements, computational power, and ability to test itself efficiently. Addressed here are the nuances of modeling the reliability of systems with large state sizes, in the Markov sense, which result from systems based on replicated redundant hardware and to discuss the modeling of factors which can reduce reliability without concomitant depletion of hardware. Advanced fault-handling models are described and methods of acquiring and measuring parameters for these models are delineated.
NASA Astrophysics Data System (ADS)
Lamour, B. G.; Harris, R. T.; Roberts, A. G.
2010-06-01
Power system reliability problems are very difficult to solve because the power systems are complex and geographically widely distributed and influenced by numerous unexpected events. It is therefore imperative to employ the most efficient optimization methods in solving the problems relating to reliability of the power system. This paper presents a reliability analysis and study of the power interruptions resulting from severe power outages in the Nelson Mandela Bay Municipality (NMBM), South Africa and includes an overview of the important factors influencing reliability, and methods to improve the reliability. The Blue Horizon Bay 22 kV overhead line, supplying a 6.6 kV residential sector has been selected. It has been established that 70% of the outages, recorded at the source, originate on this feeder.
System and Software Reliability (C103)
NASA Technical Reports Server (NTRS)
Wallace, Dolores
2003-01-01
Within the last decade better reliability models (hardware. software, system) than those currently used have been theorized and developed but not implemented in practice. Previous research on software reliability has shown that while some existing software reliability models are practical, they are no accurate enough. New paradigms of development (e.g. OO) have appeared and associated reliability models have been proposed posed but not investigated. Hardware models have been extensively investigated but not integrated into a system framework. System reliability modeling is the weakest of the three. NASA engineers need better methods and tools to demonstrate that the products meet NASA requirements for reliability measurement. For the new models for the software component of the last decade, there is a great need to bring them into a form that they can be used on software intensive systems. The Statistical Modeling and Estimation of Reliability Functions for Systems (SMERFS'3) tool is an existing vehicle that may be used to incorporate these new modeling advances. Adapting some existing software reliability modeling changes to accommodate major changes in software development technology may also show substantial improvement in prediction accuracy. With some additional research, the next step is to identify and investigate system reliability. System reliability models could then be incorporated in a tool such as SMERFS'3. This tool with better models would greatly add value in assess in GSFC projects.
NASA Astrophysics Data System (ADS)
Tamura, Yoshinobu; Yamada, Shigeru
OSS (open source software) systems which serve as key components of critical infrastructures in our social life are still ever-expanding now. Especially, embedded OSS systems have been gaining a lot of attention in the embedded system area, i.e., Android, BusyBox, TRON, etc. However, the poor handling of quality problem and customer support prohibit the progress of embedded OSS. Also, it is difficult for developers to assess the reliability and portability of embedded OSS on a single-board computer. In this paper, we propose a method of software reliability assessment based on flexible hazard rates for the embedded OSS. Also, we analyze actual data of software failure-occurrence time-intervals to show numerical examples of software reliability assessment for the embedded OSS. Moreover, we compare the proposed hazard rate model for the embedded OSS with the typical conventional hazard rate models by using the comparison criteria of goodness-of-fit. Furthermore, we discuss the optimal software release problem for the porting-phase based on the total expected software maintenance cost.
DOT National Transportation Integrated Search
2016-09-01
Travel time and travel-time reliability have been used as performance : measures to evaluate traffic system conditions and develop advanced : traveler information and traffic management systems. The objectives of this research were to: : - Quantify s...
NASA Advanced Exploration Systems: Advancements in Life Support Systems
NASA Technical Reports Server (NTRS)
Shull, Sarah A.; Schneider, Walter F.
2016-01-01
The NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) project strives to develop reliable, energy-efficient, and low-mass spacecraft systems to provide environmental control and life support systems (ECLSS) critical to enabling long duration human missions beyond low Earth orbit (LEO). Highly reliable, closed-loop life support systems are among the capabilities required for the longer duration human space exploration missions assessed by NASA’s Habitability Architecture Team.
NASA Technical Reports Server (NTRS)
Dennehy, Cornelius J.
2010-01-01
This final report summarizes the results of a comparative assessment of the fault tolerance and reliability of different Guidance, Navigation and Control (GN&C) architectural approaches. This study was proactively performed by a combined Massachusetts Institute of Technology (MIT) and Draper Laboratory team as a GN&C "Discipline-Advancing" activity sponsored by the NASA Engineering and Safety Center (NESC). This systematic comparative assessment of GN&C system architectural approaches was undertaken as a fundamental step towards understanding the opportunities for, and limitations of, architecting highly reliable and fault tolerant GN&C systems composed of common avionic components. The primary goal of this study was to obtain architectural 'rules of thumb' that could positively influence future designs in the direction of an optimized (i.e., most reliable and cost-efficient) GN&C system. A secondary goal was to demonstrate the application and the utility of a systematic modeling approach that maps the entire possible architecture solution space.
Downer, Jason T.; Booren, Leslie M.; Lima, Olivia K.; Luckner, Amy E.; Pianta, Robert C.
2012-01-01
This paper introduces the Individualized Classroom Assessment Scoring System (inCLASS), an observation tool that targets children’s interactions in preschool classrooms with teachers, peers, and tasks. In particular, initial evidence is reported of the extent to which the inCLASS meets the following psychometric criteria: inter-rater reliability, normal distributions and adequate range, construct validity, and criterion-related validity. These initial findings suggest that the inCLASS has the potential to provide an authentic, contextualized assessment of young children’s classroom behaviors. Future directions for research with the inCLASS are discussed. PMID:23175598
Rosen, Jules; Mulsant, Benoit H; Marino, Patricia; Groening, Christopher; Young, Robert C; Fox, Debra
2008-10-30
Despite the importance of establishing shared scoring conventions and assessing interrater reliability in clinical trials in psychiatry, these elements are often overlooked. Obstacles to rater training and reliability testing include logistic difficulties in providing live training sessions, or mailing videotapes of patients to multiple sites and collecting the data for analysis. To address some of these obstacles, a web-based interactive video system was developed. It uses actors of diverse ages, gender and race to train raters how to score the Hamilton Depression Rating Scale and to assess interrater reliability. This system was tested with a group of experienced and novice raters within a single site. It was subsequently used to train raters of a federally funded multi-center clinical trial on scoring conventions and to test their interrater reliability. The advantages and limitations of using interactive video technology to improve the quality of clinical trials are discussed.
Assessing the competences associated with a nursing Bachelor thesis by means of rubrics.
Llaurado-Serra, M; Rodríguez, E; Gallart, A; Fuster, P; Monforte-Royo, C; De Juan, M Á
2018-07-01
Writing a Bachelor thesis is the last step in obtaining a university degree. The thesis may be job- or research-orientated, but it must demonstrate certain degree-level competences. Rubrics are a useful way of unifying the assessment criteria. To design a system of rubrics for assessing the competences associated with the Bachelor thesis of a nursing degree, to examine the system's reliability and validity and to analyse results in relation to the final thesis mark. Cross-sectional and psychometric study conducted between 2012 and 2014. Nursing degree at a Spanish university. Twelve tutors who designed the system of rubrics. Students (n = 76) who wrote their Bachelor thesis during the 2013-2014 academic year. After deciding which aspects would be assessed, who would assess them and when, the tutors developed seven rubrics (drafting process, assessment of the written thesis by the supervisor and by a panel, student self-assessment, peer assessment, tutor evaluation of the peer assessment and panel assessment of the viva). We analysed the reliability (inter-rater and internal consistency) and validity (convergent and discriminant) of the rubrics, and also the relationship between the competences assessed and the final thesis mark. All the rubrics had internal consistency coefficients >0.80. The rubric for oral communication skills (viva) yielded inter-rater reliability of 0.95. Factor analysis indicated a unidimensional structure for all but one of the rubrics, the exception being the rubric for peer assessment, which had a two-factor structure. The main competences associated with a good quality Bachelor thesis were written communication skills and the ability to work independently. The assessment system based on seven rubrics is shown to be valid and reliable. Writing a Bachelor thesis requires a range of degree-level competences and it offers nursing students the opportunity to develop their evidence-based practice skills. Copyright © 2018 Elsevier Ltd. All rights reserved.
[Design of low-intermediate frequency electrotherapy and pain assessment system].
Liang, Chunyan; Tian, Xuelong; Yu, Xuehong; Luo, Hongyan
2014-06-01
Aiming at the single treatment and the design separation between treatment and assessment in electrotherapy equipment, a kind of system including low-intermediate frequency treatment and efficacy evaluation was developed. With C8051F020 single-chip microcomputer as the core and the circuit design and software programming used, the system realized the random switch of therapeutic parameters, the collection, display and data storage of pressure pain threshold in the assessment. Experiment results showed that the stimulus waveform, current intensity, frequency, duty ratio of the system output were adjustable, accurate and reliable. The obtained pressure pain threshold had a higher accuracy (< 0.3 N) and better stability, guiding the parameter choice in the precise electrical stimulation. It, therefore, provides a reliable technical support for the treatment and curative effect assessment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bucknor, Matthew; Grabaskas, David; Brunett, Acacia J.
We report that many advanced reactor designs rely on passive systems to fulfill safety functions during accident sequences. These systems depend heavily on boundary conditions to induce a motive force, meaning the system can fail to operate as intended because of deviations in boundary conditions, rather than as the result of physical failures. Furthermore, passive systems may operate in intermediate or degraded modes. These factors make passive system operation difficult to characterize within a traditional probabilistic framework that only recognizes discrete operating modes and does not allow for the explicit consideration of time-dependent boundary conditions. Argonne National Laboratory has beenmore » examining various methodologies for assessing passive system reliability within a probabilistic risk assessment for a station blackout event at an advanced small modular reactor. This paper provides an overview of a passive system reliability demonstration analysis for an external event. Considering an earthquake with the possibility of site flooding, the analysis focuses on the behavior of the passive Reactor Cavity Cooling System following potential physical damage and system flooding. The assessment approach seeks to combine mechanistic and simulation-based methods to leverage the benefits of the simulation-based approach without the need to substantially deviate from conventional probabilistic risk assessment techniques. Lastly, although this study is presented as only an example analysis, the results appear to demonstrate a high level of reliability of the Reactor Cavity Cooling System (and the reactor system in general) for the postulated transient event.« less
Evaluation of Urinary Tract Dilation Classification System for Grading Postnatal Hydronephrosis.
Hodhod, Amr; Capolicchio, John-Paul; Jednak, Roman; El-Sherif, Eid; El-Doray, Abd El-Alim; El-Sherbiny, Mohamed
2016-03-01
We assessed the reliability and validity of the Urinary Tract Dilation classification system as a new grading system for postnatal hydronephrosis. We retrospectively reviewed charts of patients who presented with hydronephrosis from 2008 to 2013. We included patients diagnosed prenatally and those with hydronephrosis discovered incidentally during the first year of life. We excluded cases involving urinary tract infection, neurogenic bladder and chromosomal anomalies, those associated with extraurinary congenital malformations and those with followup of less than 24 months without resolution. Hydronephrosis was graded postnatally using the Society for Fetal Urology system, and then the management protocol was chosen. All units were regraded using the Urinary Tract Dilation classification system and compared to the Society for Fetal Urology system to assess reliability. Univariate and multivariate analyses were performed to assess the validity of the Urinary Tract Dilation classification system in predicting hydronephrosis resolution and surgical intervention. A total of 490 patients (730 renal units) were eligible to participate. The Urinary Tract Dilation classification system was reliable in the assessment of hydronephrosis (parallel forms 0.92). Hydronephrosis resolved in 357 units (49%), and 86 units (12%) were managed by surgical intervention. The remainder of renal units demonstrated stable or improved hydronephrosis. Multivariate analysis revealed that the likelihood of surgical intervention was predicted independently by Urinary Tract Dilation classification system risk group, while Society for Fetal Urology grades were predictive of likelihood of resolution. The Urinary Tract Dilation classification system is reliable for evaluation of postnatal hydronephrosis and is valid in predicting surgical intervention. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Chang, Jasper O; Levy, Susan S; Seay, Seth W; Goble, Daniel J
2014-05-01
Recent guidelines advocate sports medicine professionals to use balance tests to assess sensorimotor status in the management of concussions. The present study sought to determine whether a low-cost balance board could provide a valid, reliable, and objective means of performing this balance testing. Criterion validity testing relative to a gold standard and 7 day test-retest reliability. University biomechanics laboratory. Thirty healthy young adults. Balance ability was assessed on 2 days separated by 1 week using (1) a gold standard measure (ie, scientific grade force plate), (2) a low-cost Nintendo Wii Balance Board (WBB), and (3) the Balance Error Scoring System (BESS). Validity of the WBB center of pressure path length and BESS scores were determined relative to the force plate data. Test-retest reliability was established based on intraclass correlation coefficients. Composite scores for the WBB had excellent validity (r = 0.99) and test-retest reliability (R = 0.88). Both the validity (r = 0.10-0.52) and test-retest reliability (r = 0.61-0.78) were lower for the BESS. These findings demonstrate that a low-cost balance board can provide improved balance testing accuracy/reliability compared with the BESS. This approach provides a potentially more valid/reliable, yet affordable, means of assessing sports-related concussion compared with current methods.
ERIC Educational Resources Information Center
Humpherys, Sean LaMarc
2010-01-01
Given the increasing problem of fraud, crime, and national security threats, assessing credibility is a recurring research topic in Information Systems and in other disciplines. Decision support systems can help. But the success of the system depends on reliable cues that can distinguish deceptive/truthful behavior and on a proven classification…
Psychometrics of the MHSIP Adult Consumer Survey.
Jerrell, Jeanette M
2006-10-01
The reliability and validity of the Mental Health Statistics Improvement Program (MHSIP) Adult Consumer Survey were assessed in a statewide convenience sample of 459 persons with severe mental illness served through a public mental health system. Consistent with previous findings and the intent of its developers, three factors were identified that demonstrate good internal consistency, moderate test-retest reliability, and good convergent validity with consumer perceptions of other aspects of their care. The reliability and validity of the MHSIP Adult Consumer Survey documented in this study underscore its scientific and practical utility as an abbreviated tool for assessing access, quality and appropriateness, and outcome in mental health service systems.
Bridge reliability assessment based on the PDF of long-term monitored extreme strains
NASA Astrophysics Data System (ADS)
Jiao, Meiju; Sun, Limin
2011-04-01
Structural health monitoring (SHM) systems can provide valuable information for the evaluation of bridge performance. As the development and implementation of SHM technology in recent years, the data mining and use has received increasingly attention and interests in civil engineering. Based on the principle of probabilistic and statistics, a reliability approach provides a rational basis for analysis of the randomness in loads and their effects on structures. A novel approach combined SHM systems with reliability method to evaluate the reliability of a cable-stayed bridge instrumented with SHM systems was presented in this paper. In this study, the reliability of the steel girder of the cable-stayed bridge was denoted by failure probability directly instead of reliability index as commonly used. Under the assumption that the probability distributions of the resistance are independent to the responses of structures, a formulation of failure probability was deduced. Then, as a main factor in the formulation, the probability density function (PDF) of the strain at sensor locations based on the monitoring data was evaluated and verified. That Donghai Bridge was taken as an example for the application of the proposed approach followed. In the case study, 4 years' monitoring data since the operation of the SHM systems was processed, and the reliability assessment results were discussed. Finally, the sensitivity and accuracy of the novel approach compared with FORM was discussed.
Sensor validation and fusion for gas turbine vibration monitoring
NASA Astrophysics Data System (ADS)
Yan, Weizhong; Goebel, Kai F.
2003-08-01
Vibration monitoring is an important practice throughout regular operation of gas turbine power systems and, even more so, during characterization tests. Vibration monitoring relies on accurate and reliable sensor readings. To obtain accurate readings, sensors are placed such that the signal is maximized. In the case of characterization tests, strain gauges are placed at the location of vibration modes on blades inside the gas turbine. Due to the prevailing harsh environment, these sensors have a limited life and decaying accuracy, both of which impair vibration assessment. At the same time bandwidth limitations may restrict data transmission, which in turn limits the number of sensors that can be used for assessment. Knowing the sensor status (normal or faulty), and more importantly, knowing the true vibration level of the system all the time is essential for successful gas turbine vibration monitoring. This paper investigates a dynamic sensor validation and system health reasoning scheme that addresses the issues outlined above by considering only the information required to reliably assess system health status. In particular, if abnormal system health is suspected or if the primary sensor is determined to be faulted, information from available "sibling" sensors is dynamically integrated. A confidence expresses the complex interactions of sensor health and system health, their reliabilities, conflicting information, and what the health assessment is. Effectiveness of the scheme in achieving accurate and reliable vibration evaluation is then demonstrated using a combination of simulated data and a small sample of a real-world application data where the vibration of compressor blades during a real time characterization test of a new gas turbine power system is monitored.
GN&C Engineering Best Practices for Human-Rated Spacecraft Systems
NASA Technical Reports Server (NTRS)
Dennehy, Cornelius J.; Lebsock, Kenneth; West, John
2007-01-01
The NASA Engineering and Safety Center (NESC) recently completed an in-depth assessment to identify a comprehensive set of engineering considerations for the Design, Development, Test and Evaluation (DDT&E) of safe and reliable human-rated spacecraft systems. Reliability subject matter experts, discipline experts, and systems engineering experts were brought together to synthesize the current "best practices" both at the spacecraft system and subsystems levels. The objective of this paper is to summarize, for the larger Community of Practice, the initial set of Guidance, Navigation and Control (GN&C) engineering Best Practices as identified by this NESC assessment process.
GN&C Engineering Best Practices for Human-Rated Spacecraft System
NASA Technical Reports Server (NTRS)
Dennehy, Cornelius J.; Lebsock, Kenneth; West, John
2008-01-01
The NASA Engineering and Safety Center (NESC) recently completed an in-depth assessment to identify a comprehensive set of engineering considerations for the Design, Development, Test and Evaluation (DDT&E) of safe and reliable human-rated spacecraft systems. Reliability subject matter experts, discipline experts, and systems engineering experts were brought together to synthesize the current "best practices" both at the spacecraft system and subsystems levels. The objective of this paper is to summarize, for the larger Community of Practice, the initial set of Guidance, Navigation and Control (GN&C) engineering Best Practices as identified by this NESC assessment process.
GN&C Engineering Best Practices For Human-Rated Spacecraft Systems
NASA Technical Reports Server (NTRS)
Dennehy, Cornelius J.; Lebsock, Kenneth; West, John
2007-01-01
The NASA Engineering and Safety Center (NESC) recently completed an in-depth assessment to identify a comprehensive set of engineering considerations for the Design, Development, Test and Evaluation (DDT&E) of safe and reliable human-rated spacecraft systems. Reliability subject matter experts, discipline experts, and systems engineering experts were brought together to synthesize the current "best practices" both at the spacecraft system and subsystems levels. The objective of this paper is to summarize, for the larger Community of Practice, the initial set of Guidance, Navigation and Control (GN&C) engineering Best Practices as identified by this NESC assessment process.
Automated Portable Test System (APTS) - A performance envelope assessment tool
NASA Technical Reports Server (NTRS)
Kennedy, R. S.; Dunlap, W. P.; Jones, M. B.; Wilkes, R. L.; Bittner, A. C., Jr.
1985-01-01
The reliability and stability of microcomputer-based psychological tests are evaluated. The hardware, test programs, and system control of the Automated Portable Test System, which assesses human performance and subjective status, are described. Subjects were administered 11 pen-and-pencil and microcomputer-based tests for 10 sessions. The data reveal that nine of the 10 tests stabilized by the third administration; inertial correlations were high and consistent. It is noted that the microcomputer-based tests display good psychometric properties in terms of differential stability and reliability.
Evaluation of power system security and development of transmission pricing method
NASA Astrophysics Data System (ADS)
Kim, Hyungchul
The electric power utility industry is presently undergoing a change towards the deregulated environment. This has resulted in unbundling of generation, transmission and distribution services. The introduction of competition into unbundled electricity services may lead system operation closer to its security boundaries resulting in smaller operating safety margins. The competitive environment is expected to lead to lower price rates for customers and higher efficiency for power suppliers in the long run. Under this deregulated environment, security assessment and pricing of transmission services have become important issues in power systems. This dissertation provides new methods for power system security assessment and transmission pricing. In power system security assessment, the following issues are discussed (1) The description of probabilistic methods for power system security assessment; (2) The computation time of simulation methods; (3) on-line security assessment for operation. A probabilistic method using Monte-Carlo simulation is proposed for power system security assessment. This method takes into account dynamic and static effects corresponding to contingencies. Two different Kohonen networks, Self-Organizing Maps and Learning Vector Quantization, are employed to speed up the probabilistic method. The combination of Kohonen networks and Monte-Carlo simulation can reduce computation time in comparison with straight Monte-Carlo simulation. A technique for security assessment employing Bayes classifier is also proposed. This method can be useful for system operators to make security decisions during on-line power system operation. This dissertation also suggests an approach for allocating transmission transaction costs based on reliability benefits in transmission services. The proposed method shows the transmission transaction cost of reliability benefits when transmission line capacities are considered. The ratio between allocation by transmission line capacity-use and allocation by reliability benefits is computed using the probability of system failure.
Hou, Xianlong; Hodges, Ben R; Feng, Dongyu; Liu, Qixiao
2017-03-15
As oil transport increasing in the Texas bays, greater risks of ship collisions will become a challenge, yielding oil spill accidents as a consequence. To minimize the ecological damage and optimize rapid response, emergency managers need to be informed with how fast and where oil will spread as soon as possible after a spill. The state-of-the-art operational oil spill forecast modeling system improves the oil spill response into a new stage. However uncertainty due to predicted data inputs often elicits compromise on the reliability of the forecast result, leading to misdirection in contingency planning. Thus understanding the forecast uncertainty and reliability become significant. In this paper, Monte Carlo simulation is implemented to provide parameters to generate forecast probability maps. The oil spill forecast uncertainty is thus quantified by comparing the forecast probability map and the associated hindcast simulation. A HyosPy-based simple statistic model is developed to assess the reliability of an oil spill forecast in term of belief degree. The technologies developed in this study create a prototype for uncertainty and reliability analysis in numerical oil spill forecast modeling system, providing emergency managers to improve the capability of real time operational oil spill response and impact assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wangensteen, Arnlaug; Tol, Johannes L; Roemer, Frank W; Bahr, Roald; Dijkstra, H Paul; Crema, Michel D; Farooq, Abdulaziz; Guermazi, Ali
2017-04-01
To assess and compare the intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injury. Male athletes (n=40) with clinical diagnosis of acute hamstring injury and MRI ≤5days were selected from a prospective cohort. Two radiologists independently evaluated the MRIs using standardised scoring form including the modified Peetrons grading system, the Chan acute muscle strain injury classification and the British Athletics Muscle Injury Classification. Intra-and interrater reliability was assessed with linear weighted kappa (κ) or unweighted Cohen's κ and percentage agreement was calculated. We observed 'substantial' to 'almost perfect' intra- (κ range 0.65-1.00) and interrater reliability (κ range 0.77-1.00) with percentage agreement 83-100% and 88-100%, respectively, for severity gradings, overall anatomical sites and overall classifications for the three MRI systems. We observed substantial variability (κ range -0.05 to 1.00) for subcategories within the Chan classification and the British Athletics Muscle Injury Classification, however, the prevalence of positive scorings was low for some subcategories. The modified Peetrons grading system, overall Chan classification and overall British Athletics Muscle Injury Classification demonstrated 'substantial' to 'almost perfect' intra- and interrater reliability when scored by experienced radiologists. The intra- and interrater reliability for the anatomical subcategories within the classifications remains unclear. Copyright © 2017 Elsevier B.V. All rights reserved.
Peterson, Eleanor B; Calhoun, Aaron W; Rider, Elizabeth A
2014-09-01
With increased recognition of the importance of sound communication skills and communication skills education, reliable assessment tools are essential. This study reports on the psychometric properties of an assessment tool based on the Kalamazoo Consensus Statement Essential Elements Communication Checklist. The Gap-Kalamazoo Communication Skills Assessment Form (GKCSAF), a modified version of an existing communication skills assessment tool, the Kalamazoo Essential Elements Communication Checklist-Adapted, was used to assess learners in a multidisciplinary, simulation-based communication skills educational program using multiple raters. 118 simulated conversations were available for analysis. Internal consistency and inter-rater reliability were determined by calculating a Cronbach's alpha score and intra-class correlation coefficients (ICC), respectively. The GKCSAF demonstrated high internal consistency with a Cronbach's alpha score of 0.844 (faculty raters) and 0.880 (peer observer raters), and high inter-rater reliability with an ICC of 0.830 (faculty raters) and 0.89 (peer observer raters). The Gap-Kalamazoo Communication Skills Assessment Form is a reliable method of assessing the communication skills of multidisciplinary learners using multi-rater methods within the learning environment. The Gap-Kalamazoo Communication Skills Assessment Form can be used by educational programs that wish to implement a reliable assessment and feedback system for a variety of learners. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.
2010-01-01
Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, David; Brunett, Acacia J.; Passerini, Stefano
GE Hitachi Nuclear Energy (GEH) and Argonne National Laboratory (Argonne) participated in a two year collaboration to modernize and update the probabilistic risk assessment (PRA) for the PRISM sodium fast reactor. At a high level, the primary outcome of the project was the development of a next-generation PRA that is intended to enable risk-informed prioritization of safety- and reliability-focused research and development. A central Argonne task during this project was a reliability assessment of passive safety systems, which included the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedbacks of the metal fuel core. Both systems were examinedmore » utilizing a methodology derived from the Reliability Method for Passive Safety Functions (RMPS), with an emphasis on developing success criteria based on mechanistic system modeling while also maintaining consistency with the Fuel Damage Categories (FDCs) of the mechanistic source term assessment. This paper provides an overview of the reliability analyses of both systems, including highlights of the FMEAs, the construction of best-estimate models, uncertain parameter screening and propagation, and the quantification of system failure probability. In particular, special focus is given to the methodologies to perform the analysis of uncertainty propagation and the determination of the likelihood of violating FDC limits. Additionally, important lessons learned are also reviewed, such as optimal sampling methodologies for the discovery of low likelihood failure events and strategies for the combined treatment of aleatory and epistemic uncertainties.« less
The Modified Cognitive Constructions Coding System: Reliability and Validity Assessments
ERIC Educational Resources Information Center
Moran, Galia S.; Diamond, Gary M.
2006-01-01
The cognitive constructions coding system (CCCS) was designed for coding client's expressed problem constructions on four dimensions: intrapersonal-interpersonal, internal-external, responsible-not responsible, and linear-circular. This study introduces, and examines the reliability and validity of, a modified version of the CCCS--a version that…
77 FR 53877 - Commission Information Collection Activities (FERC-715); Comment Request; Extension
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-04
...; A detailed description of the transmission planning reliability criteria used to evaluate system... reliability criteria are applied and the steps taken in performing transmission planning studies); and A... reliability criteria using its stated assessment practices. The FERC-715 enables the Commission to use the...
NASA Technical Reports Server (NTRS)
Miller, James; Leggett, Jay; Kramer-White, Julie
2008-01-01
A team directed by the NASA Engineering and Safety Center (NESC) collected methodologies for how best to develop safe and reliable human rated systems and how to identify the drivers that provide the basis for assessing safety and reliability. The team also identified techniques, methodologies, and best practices to assure that NASA can develop safe and reliable human rated systems. The results are drawn from a wide variety of resources, from experts involved with the space program since its inception to the best-practices espoused in contemporary engineering doctrine. This report focuses on safety and reliability considerations and does not duplicate or update any existing references. Neither does it intend to replace existing standards and policy.
Measurement in Sensory Modulation: The Sensory Processing Scale Assessment
Miller, Lucy J.; Sullivan, Jillian C.
2014-01-01
OBJECTIVE. Sensory modulation issues have a significant impact on participation in daily life. Moreover, understanding phenotypic variation in sensory modulation dysfunction is crucial for research related to defining homogeneous groups and for clinical work in guiding treatment planning. We thus evaluated the new Sensory Processing Scale (SPS) Assessment. METHOD. Research included item development, behavioral scoring system development, test administration, and item analyses to evaluate reliability and validity across sensory domains. RESULTS. Items with adequate reliability (internal reliability >.4) and discriminant validity (p < .01) were retained. Feedback from the expert panel also contributed to decisions about retaining items in the scale. CONCLUSION. The SPS Assessment appears to be a reliable and valid measure of sensory modulation (scale reliability >.90; discrimination between group effect sizes >1.00). This scale has the potential to aid in differential diagnosis of sensory modulation issues. PMID:25184464
Interrater reliability of a Pilates movement-based classification system.
Yu, Kwan Kenny; Tulloch, Evelyn; Hendrick, Paul
2015-01-01
To determine the interrater reliability for identification of a specific movement pattern using a Pilates Classification system. Videos of 5 subjects performing specific movement tasks were sent to raters trained in the DMA-CP classification system. Ninety-six raters completed the survey. Interrater reliability for the detection of a directional bias was excellent (Pi = 0.92, and K(free) = 0.89). Interrater reliability for classifying an individual into a specific subgroup was moderate (Pi = 0.64, K(free) = 0.55) however raters who had completed levels 1-4 of the DMA-CP training and reported using the assessment daily demonstrated excellent reliability (Pi = 0.89 and K(free) = 0.87). The reliability of the classification system demonstrated almost perfect agreement in determining the existence of a specific movement pattern and classifying into a subgroup for experienced raters. There was a trend for greater reliability associated with increased levels of training and experience of the raters. Copyright © 2014 Elsevier Ltd. All rights reserved.
Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea
2017-01-01
Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Ib.
Sarig Bahat, Hilla; Sprecher, Elliot; Sela, Itamar; Treleaven, Julia
2016-07-01
The use of virtual reality (VR) for assessment and intervention of neck pain has previously been used and shown reliable for cervical range of motion measures. Neck VR enables analysis of task-oriented neck movement by stimulating responsive movements to external stimuli. Therefore, the purpose of this study was to establish inter-tester reliability of neck kinematic measures so that it can be used as a reliable assessment and treatment tool between clinicians. This reliability study included 46 asymptomatic participants, who were assessed using the neck VR system which displayed an interactive VR scenario via a head-mounted device, controlled by neck movements. The objective of the interactive assessment was to hit 16 targets, randomly appearing in four directions, as fast as possible. Each participant was tested twice by two different testers. Good reliability was found of neck motion kinematic measures in flexion, extension, and rotation (0.64-0.93 inter-class correlation). High reliability was shown for peak velocity globally (0.93), in left rotation (0.9), right rotation and extension (0.88), and flexion (0.86). Mean velocity had a good global reliability (0.84), except for left rotation directed movement with moderate reliability (0.68). Minimal detectable change for peak velocity ranged from 41 to 53 °/s, while mean velocity ranged from 20 to 25 °/s. The results suggest high reliability for peak and mean velocity as measured by the interactive Neck VR assessment of neck motion kinematics. VR appears to provide a reliable and more ecologically valid method of cervical motion evaluation than previous conventional methodologies.
HTGR plant availability and reliability evaluations. Volume I. Summary of evaluations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cadwallader, G.J.; Hannaman, G.W.; Jacobsen, F.K.
1976-12-01
The report (1) describes a reliability assessment methodology for systematically locating and correcting areas which may contribute to unavailability of new and uniquely designed components and systems, (2) illustrates the methodology by applying it to such components in a high-temperature gas-cooled reactor (Public Service Company of Colorado's Fort St. Vrain 330-MW(e) HTGR), and (3) compares the results of the assessment with actual experience. The methodology can be applied to any component or system; however, it is particularly valuable for assessments of components or systems which provide essential functions, or the failure or mishandling of which could result in relatively largemore » economic losses.« less
The Adult Attachment Projective Picture System: integrating attachment into clinical assessment.
George, Carol; West, Malcolm
2011-01-01
This article summarizes the development and validation of the Adult Attachment Projective System (AAP), a measure we developed from the Bowlby-Ainsworth developmental tradition to assess adult attachment status. The AAP has demonstrated excellent concurrent validity with the Adult Attachment Interview (George, Kaplan, & Main, 1984/1985/1996; Main & Goldwyn, 1985-1994; Main, Goldwyn, & Hesse, 2003), interjudge reliability, and test-retest reliability, with no effects of verbal intelligence or social desirability. The AAP coding and classification system and application in clinical and community samples are summarized. Finally, we introduce the 3 other articles that are part of this Special Section and discuss the use of the AAP in therapeutic assessment and treatment.
Achieving Reliable Communication in Dynamic Emergency Responses
Chipara, Octav; Plymoth, Anders N.; Liu, Fang; Huang, Ricky; Evans, Brian; Johansson, Per; Rao, Ramesh; Griswold, William G.
2011-01-01
Emergency responses require the coordination of first responders to assess the condition of victims, stabilize their condition, and transport them to hospitals based on the severity of their injuries. WIISARD is a system designed to facilitate the collection of medical information and its reliable dissemination during emergency responses. A key challenge in WIISARD is to deliver data with high reliability as first responders move and operate in a dynamic radio environment fraught with frequent network disconnections. The initial WIISARD system employed a client-server architecture and an ad-hoc routing protocol was used to exchange data. The system had low reliability when deployed during emergency drills. In this paper, we identify the underlying causes of unreliability and propose a novel peer-to-peer architecture that in combination with a gossip-based communication protocol achieves high reliability. Empirical studies show that compared to the initial WIISARD system, the redesigned system improves reliability by as much as 37% while reducing the number of transmitted packets by 23%. PMID:22195075
Fast Computation and Assessment Methods in Power System Analysis
NASA Astrophysics Data System (ADS)
Nagata, Masaki
Power system analysis is essential for efficient and reliable power system operation and control. Recently, online security assessment system has become of importance, as more efficient use of power networks is eagerly required. In this article, fast power system analysis techniques such as contingency screening, parallel processing and intelligent systems application are briefly surveyed from the view point of their application to online dynamic security assessment.
Gunnarsson, U; Johansson, M; Strigård, K
2011-08-01
The decrease in recurrence rates in ventral hernia surgery have led to a redirection of focus towards other important patient-related endpoints. One such endpoint is abdominal wall function. The aim of the present study was to evaluate the reliability and external validity of abdominal wall strength measurement using the Biodex System-4 with a back abdomen unit. Ten healthy volunteers and ten patients with ventral hernias exceeding 10 cm were recruited. Test-retest reliability, both with and without girdle, was evaluated by comparison of measurements at two test occasions 1 week apart. Reliability was calculated by the interclass correlation coefficients (ICC) method. Validity was evaluated by correlation with the well-established International Physical Activity Questionnaire (IPAQ) and a self-assessment of abdominal wall strength. One person in the healthy group was excluded after the first test due to neck problems following minor trauma. The reliability was excellent (>0.75), with ICC values between 0.92 and 0.97 for the different modalities tested. No differences were seen between testing with and without a girdle. Validity was also excellent both when calculated as correlation to self-assessment of abdominal wall strength, and to IPAQ, giving Kendall tau values of 0.51 and 0.47, respectively, and corresponding P values of 0.002 and 0.004. Measurement of abdominal muscle function using the Biodex System-4 is a reliable and valid method to assess this important patient-related endpoint. Further investigations will be made to explore the potential of this technique in the evaluation of the results of ventral hernia surgery, and to compare muscle function after different abdominal wall reconstruction techniques.
McAlpine, R T; Bettany-Saltikov, J A; Warren, J G
2009-01-01
Assessment of spinal posture during physiotherapy practice is routine, yet few objective measures exist to this end. The Middlesbrough Integrated Digital Assessment System (MIDAS) is a low cost portable system able to record 3D information on posture. The purpose of this study was to assess both the intra-rater and inter-rater reliability of the MIDAS system. Twenty-five healthy subjects were recruited. A repeated measures design was used to record fifteen pre-palpated landmarks on the back of each subject. To limit the sources of variability, the principal researcher palpated the landmarks for each subject. Each of three raters took two measurements on each subject in a standardized upright posture. X (medio-lateral), Y (antero-posterior) and Z (height) landmark positions were recorded via a computer interface. Both intra-rater agreement (mean ICCs - rater 1 r=0.970, rater 2 r=0.965 and rater 3 r=0.965, p< 0.001) and inter-rater agreement (mean ICCs r=0.967, p< 0.001) was very high between repeated measures and between markers. Error values for the z-axis (height) were the lowest. The MIDAS demonstrated both high inter-rater and intra-rater reliability and provides an objective method for the assessment of posture in physiotherapy practice.
Reliability Assessment Approach for Stirling Convertors and Generators
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Schreiber, Jeffrey G.; Zampino, Edward; Best, Timothy
2004-01-01
Stirling power conversion is being considered for use in a Radioisotope Power System for deep-space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power. Quantifying the reliability of a Radioisotope Power System that utilizes Stirling power conversion technology is important in developing and demonstrating the capability for long-term success. A description of the Stirling power convertor is provided, along with a discussion about some of the key components. Ongoing efforts to understand component life, design variables at the component and system levels, related sources, and the nature of uncertainties is discussed. The requirement for reliability also is discussed, and some of the critical areas of concern are identified. A section on the objectives of the performance model development and a computation of reliability is included to highlight the goals of this effort. Also, a viable physics-based reliability plan to model the design-level variable uncertainties at the component and system levels is outlined, and potential benefits are elucidated. The plan involves the interaction of different disciplines, maintaining the physical and probabilistic correlations at all the levels, and a verification process based on rational short-term tests. In addition, both top-down and bottom-up coherency were maintained to follow the physics-based design process and mission requirements. The outlined reliability assessment approach provides guidelines to improve the design and identifies governing variables to achieve high reliability in the Stirling Radioisotope Generator design.
ERIC Educational Resources Information Center
Colbert, Peta; Wyatt-Smith, Claire; Klenowski, Val
2012-01-01
This article considers the conditions that are necessary at system and local levels for teacher assessment to be valid, reliable and rigorous. With sustainable assessment cultures as a goal, the article examines how education systems can support local-level efforts for quality learning and dependable teacher assessment. This is achieved through…
Nanoscale deformation measurements for reliability assessment of material interfaces
NASA Astrophysics Data System (ADS)
Keller, Jürgen; Gollhardt, Astrid; Vogel, Dietmar; Michel, Bernd
2006-03-01
With the development and application of micro/nano electronic mechanical systems (MEMS, NEMS) for a variety of market segments new reliability issues will arise. The understanding of material interfaces is the key for a successful design for reliability of MEMS/NEMS and sensor systems. Furthermore in the field of BIOMEMS newly developed advanced materials and well known engineering materials are combined despite of fully developed reliability concepts for such devices and components. In addition the increasing interface-to volume ratio in highly integrated systems and nanoparticle filled materials are challenges for experimental reliability evaluation. New strategies for reliability assessment on the submicron scale are essential to fulfil the needs of future devices. In this paper a nanoscale resolution experimental method for the measurement of thermo-mechanical deformation at material interfaces is introduced. The determination of displacement fields is based on scanning probe microscopy (SPM) data. In-situ SPM scans of the analyzed object (i.e. material interface) are carried out at different thermo-mechanical load states. The obtained images are compared by grayscale cross correlation algorithms. This allows the tracking of local image patterns of the analyzed surface structure. The measurement results are full-field displacement fields with nanometer resolution. With the obtained data the mixed mode type of loading at material interfaces can be analyzed with highest resolution for future needs in micro system and nanotechnology.
An overview of reliability assessment and control for design of civil engineering structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Field, R.V. Jr.; Grigoriadis, K.M.; Bergman, L.A.
1998-06-01
Random variations, whether they occur in the input signal or the system parameters, are phenomena that occur in nearly all engineering systems of interest. As a result, nondeterministic modeling techniques must somehow account for these variations to ensure validity of the solution. As might be expected, this is a difficult proposition and the focus of many current research efforts. Controlling seismically excited structures is one pertinent application of nondeterministic analysis and is the subject of the work presented herein. This overview paper is organized into two sections. First, techniques to assess system reliability, in a context familiar to civil engineers,more » are discussed. Second, and as a consequence of the first, active control methods that ensure good performance in this random environment are presented. It is the hope of the authors that these discussions will ignite further interest in the area of reliability assessment and design of controlled civil engineering structures.« less
Sensor Systems for Prognostics and Health Management
Cheng, Shunfeng; Azarian, Michael H.; Pecht, Michael G.
2010-01-01
Prognostics and health management (PHM) is an enabling discipline consisting of technologies and methods to assess the reliability of a product in its actual life cycle conditions to determine the advent of failure and mitigate system risk. Sensor systems are needed for PHM to monitor environmental, operational, and performance-related characteristics. The gathered data can be analyzed to assess product health and predict remaining life. In this paper, the considerations for sensor system selection for PHM applications, including the parameters to be measured, the performance needs, the electrical and physical attributes, reliability, and cost of the sensor system, are discussed. The state-of-the-art sensor systems for PHM and the emerging trends in technologies of sensor systems for PHM are presented. PMID:22219686
Sensor systems for prognostics and health management.
Cheng, Shunfeng; Azarian, Michael H; Pecht, Michael G
2010-01-01
Prognostics and health management (PHM) is an enabling discipline consisting of technologies and methods to assess the reliability of a product in its actual life cycle conditions to determine the advent of failure and mitigate system risk. Sensor systems are needed for PHM to monitor environmental, operational, and performance-related characteristics. The gathered data can be analyzed to assess product health and predict remaining life. In this paper, the considerations for sensor system selection for PHM applications, including the parameters to be measured, the performance needs, the electrical and physical attributes, reliability, and cost of the sensor system, are discussed. The state-of-the-art sensor systems for PHM and the emerging trends in technologies of sensor systems for PHM are presented.
Mouthon, L; Rannou, F; Bérezné, A; Pagnoux, C; Arène, J‐P; Foïs, E; Cabane, J; Guillevin, L; Revel, M; Fermanian, J; Poiraudeau, S
2007-01-01
Objective To develop and assess the reliability and construct validity of a scale assessing disability involving the mouth in systemic sclerosis (SSc). Methods We generated a 34‐item provisional scale from mailed responses of patients (n = 74), expert consensus (n = 10) and literature analysis. A total of 71 other SSc patients were recruited. The test–retest reliability was assessed using the intraclass coefficient correlation and divergent validity using the Spearman correlation coefficient. Factor analysis followed by varimax rotation was performed to assess the factorial structure of the scale. Results The item reduction process retained 12 items with 5 levels of answers (total score range 0–48). The mean total score of the scale was 20.3 (SD 9.7). The test–retest reliability was 0.96. Divergent validity was confirmed for global disability (Health Assessment Questionnaire (HAQ), r = 0.33), hand function (Cochin Hand Function Scale, r = 0.37), inter‐incisor distance (r = −0.34), handicap (McMaster‐Toronto Arthritis questionnaire (MACTAR), r = 0.24), depression (Hospital Anxiety and Depression (HAD); HADd, r = 0.26) and anxiety (HADa, r = 0.17). Factor analysis extracted 3 factors with eigenvalues of 4.26, 1.76 and 1.47, explaining 63% of the variance. These 3 factors could be clinically characterised. The first factor (5 items) represents handicap induced by the reduction in mouth opening, the second (5 items) handicap induced by sicca syndrome and the third (2 items) aesthetic concerns. Conclusion We propose a new scale, the Mouth Handicap in Systemic Sclerosis (MHISS) scale, which has excellent reliability and good construct validity, and assesses specifically disability involving the mouth in patients with SSc. PMID:17502364
NASA Astrophysics Data System (ADS)
Liu, Haixing; Savić, Dragan; Kapelan, Zoran; Zhao, Ming; Yuan, Yixing; Zhao, Hongbin
2014-07-01
Flow entropy is a measure of uniformity of pipe flows in water distribution systems. By maximizing flow entropy one can identify reliable layouts or connectivity in networks. In order to overcome the disadvantage of the common definition of flow entropy that does not consider the impact of pipe diameter on reliability, an extended definition of flow entropy, termed as diameter-sensitive flow entropy, is proposed. This new methodology is then assessed by using other reliability methods, including Monte Carlo Simulation, a pipe failure probability model, and a surrogate measure (resilience index) integrated with water demand and pipe failure uncertainty. The reliability assessment is based on a sample of WDS designs derived from an optimization process for each of the two benchmark networks. Correlation analysis is used to evaluate quantitatively the relationship between entropy and reliability. To ensure reliability, a comparative analysis between the flow entropy and the new method is conducted. The results demonstrate that the diameter-sensitive flow entropy shows consistently much stronger correlation with the three reliability measures than simple flow entropy. Therefore, the new flow entropy method can be taken as a better surrogate measure for reliability and could be potentially integrated into the optimal design problem of WDSs. Sensitivity analysis results show that the velocity parameters used in the new flow entropy has no significant impact on the relationship between diameter-sensitive flow entropy and reliability.
Assessment of Safety Standards for Automotive Electronic Control Systems
DOT National Transportation Integrated Search
2016-06-01
This report summarizes the results of a study that assessed and compared six industry and government safety standards relevant to the safety and reliability of automotive electronic control systems. These standards include ISO 26262 (Road Vehicles - ...
Jordan, D; McEwen, S A; Wilson, J B; McNab, W B; Lammerding, A M
1999-05-01
A study was conducted to provide a quantitative description of the amount of tag (mud, soil, and bedding) adhered to the hides of feedlot beef cattle and to appraise the statistical reliability of a subjective rating system for assessing this trait. Initially, a single rater obtained baseline data by assessing 2,417 cattle for 1 month at an Ontario beef processing plant. Analysis revealed that there was a strong tendency for animals within sale-lots to have a similar total tag score (intralot correlation = 0.42). Baseline data were summarized by fitting a linear model describing an individual's total tag score as the sum of their lot mean tag score (LMTS) plus an amount representing normal variation within the lot. LMTSs predicted by the linear model were adequately described by a beta distribution with parameters nu = 3.12 and omega = 5.82 scaled to fit on the 0-to-9 interval. Five raters, trained in use of the tag scoring system, made 1,334 tag score observations in a commercial abattoir, allowing reliability to be assessed at the individual level and at the lot level. High values for reliability were obtained for individual total tag score (0.84) and lot total tag score (0.83); these values suggest that the tag scoring system could be used in the marketing and slaughter of Ontario beef cattle to improve the cleanliness of animals presented for slaughter in an effort to control the entry of microbial contamination into abattoirs. Implications for the use of the tag scoring system in research are discussed.
Establishing inter-rater reliability scoring in a state trauma system.
Read-Allsopp, Christine
2004-01-01
Trauma systems rely on accurate Injury Severity Scoring (ISS) to describe trauma patient populations. Twenty-seven (27) Trauma Nurse Coordinators and Data Managers across the state of New South Wales, Australia trauma network were instructed in the uses and techniques of the Abbreviated Injury Scale (AIS) from the Association for the Advancement of Automotive Medicine. The aim is to provide accurate, reliable and valid data for the state trauma network. Four (4) months after the course a coding exercise was conducted to assess inter-rater reliability. The results show that inter-rater reliability is with accepted international standards.
ERIC Educational Resources Information Center
Furtado, Ovande, Jr.; Gallagher, Jere D.
2012-01-01
Mastery of fundamental movement skills (FMS) is an important factor in preventing weight gain and increasing physical activity. To master FMS, performance evaluation is necessary. In this study, we investigated the reliability of a new observational assessment tool. In Phase I, 110 video clips of children performing five locomotor, and six…
Missile Systems Maintenance, AFSC 411XOB/C.
1988-04-01
technician’s rating. A statistical measurement of their agreement, known as the interrater reliability (as assessed through components of variance of...senior technician’s ratings. A statistical measurement of their agreement, known as the interrater reliability (as assessed through components of...FABRICATION TRANSITORS *INPUT/OUTPUT (PERIPHERAL) DEVICES SOLID-STATE SPECIAL PURPOSE DEVICES COMPUTER MICRO PROCESSORS AND PROGRAMS POWER SUPPLIES
Cuchna, Jennifer W; Hoch, Matthew C; Hoch, Johanna M
2016-05-01
To synthesize the literature and perform a meta-analysis for both the interrater and intrarater reliability of the FMS™. Academic Search Complete, CINAHL, Medline and SportsDiscus databases were systematically searched from inception to March 2015. Studies were included if the primary purpose was to determine the interrater or intrarater reliability of the FMS™, assessed and scored all 7-items using the standard scoring criteria, provided a composite score and employed intraclass correlation coefficients (ICCs). Studies were excluded if reliability was not the primary aim, participants were injured at data collection, or a modified FMS™ or scoring system was utilized. Seven papers were included; 6 assessing interrater and 6 assessing intrarater reliability. There was moderate evidence in good interrater reliability with a summary ICC of 0.843 (95% CI = 0.640, 0.936; Q7 = 84.915, p < 0.0001). There was moderate evidence in good intrarater reliability with a summary ICC of 0.869 (95% CI = 0.785, 0.921; Q12 = 60.763, p < 0.0001). There was moderate evidence for both forms of reliability. The sensitivity assessments revealed this interpretation is stable and not influenced by any one study. Overall, the FMS™ is a reliable tool for clinical practice. Copyright © 2015 Elsevier Ltd. All rights reserved.
Monitoring Energy Balance in Breast Cancer Survivors Using a Mobile App: Reliability Study
Lozano-Lozano, Mario; Galiano-Castillo, Noelia; Martín-Martín, Lydia; Pace-Bedetti, Nicolás; Fernández-Lao, Carolina; Cantarero-Villanueva, Irene
2018-01-01
Background The majority of breast cancer survivors do not meet recommendations in terms of diet and physical activity. To address this problem, we developed a mobile health (mHealth) app for assessing and monitoring healthy lifestyles in breast cancer survivors, called the Energy Balance on Cancer (BENECA) mHealth system. The BENECA mHealth system is a novel and interactive mHealth app, which allows breast cancer survivors to engage themselves in their energy balance monitoring. BENECA was designed to facilitate adherence to healthy lifestyles in an easy and intuitive way. Objective The objective of the study was to assess the concurrent validity and test-retest reliability between the BENECA mHealth system and the gold standard assessment methods for diet and physical activity. Methods A reliability study was conducted with 20 breast cancer survivors. In the study, tri-axial accelerometers (ActiGraphGT3X+) were used as gold standard for 8 consecutive days, in addition to 2, 24-hour dietary recalls, 4 dietary records, and sociodemographic questionnaires. Two-way random effect intraclass correlation coefficients, a linear regression-analysis, and a Passing-Bablok regression were calculated. Results The reliability estimates were very high for all variables (alpha≥.90). The lowest reliability was found in fruit and vegetable intakes (alpha=.94). The reliability between the accelerometer and the dietary assessment instruments against the BENECA system was very high (intraclass correlation coefficient=.90). We found a mean match rate of 93.51% between instruments and a mean phantom rate of 3.35%. The Passing-Bablok regression analysis did not show considerable bias in fat percentage, portions of fruits and vegetables, or minutes of moderate to vigorous physical activity. Conclusions The BENECA mHealth app could be a new tool to measure energy balance in breast cancer survivors in a reliable and simple way. Our results support the use of this technology to not only to encourage changes in breast cancer survivors' lifestyles, but also to remotely monitor energy balance. Trial Registration ClinicalTrials.gov NCT02817724; https://clinicaltrials.gov/ct2/show/NCT02817724 (Archived by WebCite at http://www.webcitation.org/6xVY1buCc) PMID:29588273
Tan, Sha; Zhang, Lei; Chen, Xiaoyu; Wang, Yanqiang; Lin, Yinyao; Cai, Wei; Shan, Yilong; Qiu, Wei; Hu, Xueqiang; Lu, Zhengqi
2016-09-06
The underlying causes of minor stroke are difficult to assess. Here, we evaluate the reliability of the Chinese Ischemic Stroke Subclassification (CISS) system in patients with minor stroke, and compare it to the Trial of Org 10172 in Acute Stroke Treatment (TOAST) system. A total of 320 patients with minor stroke were retrospectively registered and categorized into different subgroups of the CISS and TOAST by two neurologists. Inter- and intra-rater agreement with the two systems were assessed with kappa statistics. The percentage of undetermined etiology (UE) cases in the CISS system was 77.3 % less than that in the TOAST system, which was statistically significant (P < 0.001). The percentage of large artery atherosclerosis (LAA) in the CISS system was 79.7 % more than that in the TOAST system, which was also statistically significant (P < 0.001). The kappa values for inter-examiner agreement were 0.898 (P = 0.031) and 0.732 (P = 0.022) for the CISS and TOAST systems, respectively. The intra-observer reliability indexes were moderate (0.569 for neurologist A, and 0.487 for neurologist B). The CISS and TOAST systems are both reliable in classifying patients with minor stroke. CISS classified more patients into known etiologic categories without sacrificing reliability.
Illinois high-speed rail four-quadrant gate reliability assessment
DOT National Transportation Integrated Search
2009-10-01
The Federal Railroad Administration (FRA) tasked the John A. Volpe National Transportation Systems Center (Volpe Center) to conduct a reliability analysis of the four-quadrant gate/vehicle detection equipment installed on the future high-speed rail (...
Baker, Nancy A; Cook, James R; Redfern, Mark S
2009-01-01
This paper describes the inter-rater and intra-rater reliability, and the concurrent validity of an observational instrument, the Keyboard Personal Computer Style instrument (K-PeCS), which assesses stereotypical postures and movements associated with computer keyboard use. Three trained raters independently rated the video clips of 45 computer keyboard users to ascertain inter-rater reliability, and then re-rated a sub-sample of 15 video clips to ascertain intra-rater reliability. Concurrent validity was assessed by comparing the ratings obtained using the K-PeCS to scores developed from a 3D motion analysis system. The overall K-PeCS had excellent reliability [inter-rater: intra-class correlation coefficients (ICC)=.90; intra-rater: ICC=.92]. Most individual items on the K-PeCS had from good to excellent reliability, although six items fell below ICC=.75. Those K-PeCS items that were assessed for concurrent validity compared favorably to the motion analysis data for all but two items. These results suggest that most items on the K-PeCS can be used to reliably document computer keyboarding style.
Scientific assessment of accuracy, skill and reliability of ocean probabilistic forecast products.
NASA Astrophysics Data System (ADS)
Wei, M.; Rowley, C. D.; Barron, C. N.; Hogan, P. J.
2016-02-01
As ocean operational centers are increasingly adopting and generating probabilistic forecast products for their customers with valuable forecast uncertainties, how to assess and measure these complicated probabilistic forecast products objectively is challenging. The first challenge is how to deal with the huge amount of the data from the ensemble forecasts. The second one is how to describe the scientific quality of probabilistic products. In fact, probabilistic forecast accuracy, skills, reliability, resolutions are different attributes of a forecast system. We briefly introduce some of the fundamental metrics such as the Reliability Diagram, Reliability, Resolution, Brier Score (BS), Brier Skill Score (BSS), Ranked Probability Score (RPS), Ranked Probability Skill Score (RPSS), Continuous Ranked Probability Score (CRPS), and Continuous Ranked Probability Skill Score (CRPSS). The values and significance of these metrics are demonstrated for the forecasts from the US Navy's regional ensemble system with different ensemble members. The advantages and differences of these metrics are studied and clarified.
Mohamad Marzuki, Muhamad Fadhil; Yaacob, Nor Azwany; Yaacob, Najib Majdi
2018-05-14
A mobile app is a programmed system designed to be used by a target user on a mobile device. The usability of such a system refers not only to the extent to which product can be used to achieve the task that it was designed for, but also its effectiveness and efficiency, as well as user satisfaction. The System Usability Scale is one of the most commonly used questionnaires used to assess the usability of a system. The original 10-item version of System Usability Scale was developed in English and thus needs to be adapted into local languages to assess the usability of a mobile apps developed in other languages. The aim of this study is to translate and validate (with cross-cultural adaptation) the English System Usability Scale questionnaire into Malay, the main language spoken in Malaysia. The development of a translated version will allow the usability of mobile apps to be assessed in Malay. Forward and backward translation of the questionnaire was conducted by groups of Malay native speakers who spoke English as their second language. The final version was obtained after reconciliation and cross-cultural adaptation. The content of the Malay System Usability Scale questionnaire for mobile apps was validated by 10 experts in mobile app development. The efficacy of the questionnaire was further probed by testing the face validity on 10 mobile phone users, followed by reliability testing involving 54 mobile phone users. The content validity index was determined to be 0.91, indicating good relevancy of the 10 items used to assess the usability of a mobile app. Calculation of the face validity index resulted in a value of 0.94, therefore indicating that the questionnaire was easily understood by the users. Reliability testing showed a Cronbach alpha value of .85 (95% CI 0.79-0.91) indicating that the translated System Usability Scale questionnaire is a reliable tool for the assessment of usability of a mobile app. The Malay System Usability Scale questionnaire is a valid and reliable tool to assess the usability of mobile app in Malaysia. ©Muhamad Fadhil Mohamad Marzuki, Nor Azwany Yaacob, Najib Majdi Yaacob. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 14.05.2018.
The Role of Reliability, Vulnerability and Resilience in the Management of Water Quality Systems
NASA Astrophysics Data System (ADS)
Lence, B. J.; Maier, H. R.
2001-05-01
The risk based performance indicators reliability, vulnerability and resilience provide measures of the frequency, magnitude and duration of the failure of water resources systems, respectively. They have been applied primarily to water supply problems, including the assessment of the performance of reservoirs and water distribution systems. Applications to water quality case studies have been limited, although the need to consider the length and magnitude of violations of a particular water quality standard has been recognized for some time. In this research, the role of reliability, vulnerability and resilience in water quality management applications is investigated by examining their significance as performance measures for water quality systems and assessing their potential for assisting in decision making processes. The importance of each performance indicator is discussed and a framework for classifying such systems, based on the relative significance of each of these indicators, is introduced and illustrated qualitatively with various case studies. Quantitative examples drawn from both lake and river water quality modeling exercises are then provided.
Reliability analysis and initial requirements for FC systems and stacks
NASA Astrophysics Data System (ADS)
Åström, K.; Fontell, E.; Virtanen, S.
In the year 2000 Wärtsilä Corporation started an R&D program to develop SOFC systems for CHP applications. The program aims to bring to the market highly efficient, clean and cost competitive fuel cell systems with rated power output in the range of 50-250 kW for distributed generation and marine applications. In the program Wärtsilä focuses on system integration and development. System reliability and availability are key issues determining the competitiveness of the SOFC technology. In Wärtsilä, methods have been implemented for analysing the system in respect to reliability and safety as well as for defining reliability requirements for system components. A fault tree representation is used as the basis for reliability prediction analysis. A dynamic simulation technique has been developed to allow for non-static properties in the fault tree logic modelling. Special emphasis has been placed on reliability analysis of the fuel cell stacks in the system. A method for assessing reliability and critical failure predictability requirements for fuel cell stacks in a system consisting of several stacks has been developed. The method is based on a qualitative model of the stack configuration where each stack can be in a functional, partially failed or critically failed state, each of the states having different failure rates and effects on the system behaviour. The main purpose of the method is to understand the effect of stack reliability, critical failure predictability and operating strategy on the system reliability and availability. An example configuration, consisting of 5 × 5 stacks (series of 5 sets of 5 parallel stacks) is analysed in respect to stack reliability requirements as a function of predictability of critical failures and Weibull shape factor of failure rate distributions.
Field Demonstration of Condition Assessment Technologies for Wastewater Collection Systems
Reliable information on pipe condition is needed to accurately estimate the remaining service life of wastewater collection system assets. Although inspections with conventional closed-circuit television (CCTV) have been the mainstay of pipeline condition assessment for decades,...
Measures of Reliability in Behavioral Observation: The Advantage of "Real Time" Data Acquisition.
ERIC Educational Resources Information Center
Hollenbeck, Albert R.; Slaby, Ronald G.
Two observers who were using an electronic digital data acquisition system were spot checked for reliability at random times over a four month period. Between-and within-observer reliability was assessed for frequency, duration, and duration-per-event measures of four infant behaviors. The results confirmed the problem of observer drift--the…
A Comparison of Laser and Video Techniques for Determining Displacement and Velocity during Running
ERIC Educational Resources Information Center
Harrison, Andrew J.; Jensen, Randall L.; Donoghue, Orna
2005-01-01
The reliability of a laser system was compared with the reliability of a video-based kinematic analysis in measuring displacement and velocity during running. Validity and reliability of the laser on static measures was also assessed at distances between 10 m and 70 m by evaluating the coefficient of variation and intraclass correlation…
Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea
2017-01-01
Summary Background Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. Objective The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Methods Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. Results All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (p<0.05) in the maximal isokinetic bilateral knee flexion torque. Conclusions The multi-joint evaluation system for the assessment of knee and ankle isokinetic and isometric strength provided reliable test-retest measures in healthy older adults. Level of evidence Ib. PMID:29264344
Casartelli, Nicola; Müller, Roland; Maffiuletti, Nicola A
2010-11-01
The aim of the present study was to verify the validity and reliability of the Myotest accelerometric system (Myotest SA, Sion, Switzerland) for the assessment of vertical jump height. Forty-four male basketball players (age range: 9-25 years) performed series of squat, countermovement and repeated jumps during 2 identical test sessions separated by 2-15 days. Flight height was simultaneously quantified with the Myotest system and validated photoelectric cells (Optojump). Two calculation methods were used to estimate the jump height from Myotest recordings: flight time (Myotest-T) and vertical takeoff velocity (Myotest-V). Concurrent validity was investigated comparing Myotest-T and Myotest-V to the criterion method (Optojump), and test-retest reliability was also examined. As regards validity, Myotest-T overestimated jumping height compared to Optojump (p < 0.001) with a systematic bias of approximately 7 cm, even though random errors were low (2.7 cm) and intraclass correlation coefficients (ICCs) where high (>0.98), that is, excellent validity. Myotest-V overestimated jumping height compared to Optojump (p < 0.001), with high random errors (>12 cm), high limits of agreement ratios (>36%), and low ICCs (<0.75), that is, poor validity. As regards reliability, Myotest-T showed high ICCs (range: 0.92-0.96), whereas Myotest-V showed low ICCs (range: 0.56-0.89), and high random errors (>9 cm). In conclusion, Myotest-T is a valid and reliable method for the assessment of vertical jump height, and its use is legitimate for field-based evaluations, whereas Myotest-V is neither valid nor reliable.
ERIC Educational Resources Information Center
Wang, Yanqing; Liang, Yaowen; Liu, Luning; Liu, Ying
2016-01-01
Multi-peer assessment has often been used by teachers to reduce personal bias and make the assessment more reliable. This study reviews the design and development of multi-peer assessment systems that detect and solve two common issues in such systems: non-consensus among group members and personal radicalness in some assessments. A multi-peer…
NASA Aerospace Flight Battery Systems Program Update
NASA Technical Reports Server (NTRS)
Manzo, Michelle; ODonnell, Patricia
1997-01-01
The objectives of NASA's Aerospace Flight Battery Systems Program is to: develop, maintain and provide tools for the validation and assessment of aerospace battery technologies; accelerate the readiness of technology advances and provide infusion paths for emerging technologies; provide NASA projects with the required database and validation guidelines for technology selection of hardware and processes relating to aerospace batteries; disseminate validation and assessment tools, quality assurance, reliability, and availability information to the NASA and aerospace battery communities; and ensure that safe, reliable batteries are available for NASA's future missions.
Lee, James
2009-01-01
The Long-Term Mechanical Circulatory Support (MCS) System Reliability Recommendation was published in the American Society for Artificial Internal Organs (ASAIO) Journal and the Annals of Thoracic Surgery in 1998. At that time, it was stated that the document would be periodically reviewed to assess its timeliness and appropriateness within 5 years. Given the wealth of clinical experience in MCS systems, a new recommendation has been drafted by consensus of a group of representatives from the medical community, academia, industry, and government. The new recommendation describes a reliability test methodology and provides detailed reliability recommendations. In addition, the new recommendation provides additional information and clinical data in appendices that are intended to assist the reliability test engineer in the development of a reliability test that is expected to give improved predictions of clinical reliability compared with past test methods. The appendices are available for download at the ASAIO journal web site at www.asaiojournal.com.
Engelken, Florian; Wassilew, Georgi I; Köhlitz, Torsten; Brockhaus, Sebastian; Hamm, Bernd; Perka, Carsten; Diederichs, und Gerd
2014-01-01
The purpose of this study was to quantify the performance of the Goutallier classification for assessing fatty degeneration of the gluteus muscles from magnetic resonance (MR) images and to compare its performance to a newly proposed system. Eighty-four hips with clinical signs of gluteal insufficiency and 50 hips from asymptomatic controls were analyzed using a standard classification system (Goutallier) and a new scoring system (Quartile). Interobserver reliability and intraobserver repeatability were determined, and accuracy was assessed by comparing readers' scores with quantitative estimates of the proportion of intramuscular fat based on MR signal intensities (gold standard). The existing Goutallier classification system and the new Quartile system performed equally well in assessing fatty degeneration of the gluteus muscles, both showing excellent levels of interrater and intrarater agreement. While the Goutallier classification system has the advantage of being widely known, the benefit of the Quartile system is that it is based on more clearly defined grades of fatty degeneration. Copyright © 2014 Elsevier Inc. All rights reserved.
System reliability of randomly vibrating structures: Computational modeling and laboratory testing
NASA Astrophysics Data System (ADS)
Sundar, V. S.; Ammanagi, S.; Manohar, C. S.
2015-09-01
The problem of determination of system reliability of randomly vibrating structures arises in many application areas of engineering. We discuss in this paper approaches based on Monte Carlo simulations and laboratory testing to tackle problems of time variant system reliability estimation. The strategy we adopt is based on the application of Girsanov's transformation to the governing stochastic differential equations which enables estimation of probability of failure with significantly reduced number of samples than what is needed in a direct simulation study. Notably, we show that the ideas from Girsanov's transformation based Monte Carlo simulations can be extended to conduct laboratory testing to assess system reliability of engineering structures with reduced number of samples and hence with reduced testing times. Illustrative examples include computational studies on a 10-degree of freedom nonlinear system model and laboratory/computational investigations on road load response of an automotive system tested on a four-post test rig.
Simpson, V; Hughes, M; Wilkinson, J; Herrick, A L; Dinsdale, G
2018-03-01
Digital ulcers are a major problem in patients with systemic sclerosis (SSc), causing severe pain and impairment of hand function. In addition, digital ulcers heal slowly and sometimes become infected, which can lead to gangrene and necessitate amputation if appropriate intervention is not taken. A reliable, objective method for assessing digital ulcer healing or progression is needed in both the clinical and research arenas. This study was undertaken to compare 2 computer-assisted planimetry methods of measurement of digital ulcer area on photographs (ellipse and freehand regions of interest [ROIs]), and to assess the reliability of photographic calibration and the 2 methods of area measurement. Photographs were taken of 107 digital ulcers in 36 patients with SSc spectrum disease. Three raters assessed the photographs. Custom software allowed raters to calibrate photograph dimensions and draw ellipse or freehand ROIs. The shapes and dimensions of the ROIs were saved for further analysis. Calibration (by a single rater performing 5 repeats per image) produced an intraclass correlation coefficient (intrarater reliability) of 0.99. The mean ± SD areas of digital ulcers assessed using ellipse and freehand ROIs were 18.7 ± 20.2 mm 2 and 17.6 ± 19.3 mm 2 , respectively. Intrarater and interrater reliability of the ellipse ROI were 0.97 and 0.77, respectively. For the freehand ROI, the intrarater and interrater reliability were 0.98 and 0.76, respectively. Our findings indicate that computer-assisted planimetry methods applied to SSc-related digital ulcers can be extremely reliable. Further work is needed to move toward applying these methods as outcome measures for clinical trials and in clinical settings. © 2017, American College of Rheumatology.
Climate and water resource change impacts and adaptation potential for US power supply
Miara, Ariel; Macknick, Jordan E.; Vorosmarty, Charles J.; ...
2017-10-30
Power plants that require cooling currently (2015) provide 85% of electricity generation in the United States. These facilities need large volumes of water and sufficiently cool temperatures for optimal operations, and projected climate conditions may lower their potential power output and affect reliability. We evaluate the performance of 1,080 thermoelectric plants across the contiguous US under future climates (2035-2064) and their collective performance at 19 North American Electric Reliability Corporation (NERC) sub-regions. Joint consideration of engineering interactions with climate, hydrology and environmental regulations reveals the region-specific performance of energy systems and the need for regional energy security and climate-water adaptationmore » strategies. Despite climate-water constraints on individual plants, the current power supply infrastructure shows potential for adaptation to future climates by capitalizing on the size of regional power systems, grid configuration and improvements in thermal efficiencies. Without placing climate-water impacts on individual plants in a broader power systems context, vulnerability assessments that aim to support adaptation and resilience strategies misgauge the extent to which regional energy systems are vulnerable. As a result, climate-water impacts can lower thermoelectric reserve margins, a measure of systems-level reliability, highlighting the need to integrate climate-water constraints on thermoelectric power supply into energy planning, risk assessments, and system reliability management.« less
Climate and water resource change impacts and adaptation potential for US power supply
NASA Astrophysics Data System (ADS)
Miara, Ariel; Macknick, Jordan E.; Vörösmarty, Charles J.; Tidwell, Vincent C.; Newmark, Robin; Fekete, Balazs
2017-11-01
Power plants that require cooling currently (2015) provide 85% of electricity generation in the United States. These facilities need large volumes of water and sufficiently cool temperatures for optimal operations, and projected climate conditions may lower their potential power output and affect reliability. We evaluate the performance of 1,080 thermoelectric plants across the contiguous US under future climates (2035-2064) and their collective performance at 19 North American Electric Reliability Corporation (NERC) sub-regions. Joint consideration of engineering interactions with climate, hydrology and environmental regulations reveals the region-specific performance of energy systems and the need for regional energy security and climate-water adaptation strategies. Despite climate-water constraints on individual plants, the current power supply infrastructure shows potential for adaptation to future climates by capitalizing on the size of regional power systems, grid configuration and improvements in thermal efficiencies. Without placing climate-water impacts on individual plants in a broader power systems context, vulnerability assessments that aim to support adaptation and resilience strategies misgauge the extent to which regional energy systems are vulnerable. Climate-water impacts can lower thermoelectric reserve margins, a measure of systems-level reliability, highlighting the need to integrate climate-water constraints on thermoelectric power supply into energy planning, risk assessments, and system reliability management.
Climate and water resource change impacts and adaptation potential for US power supply
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miara, Ariel; Macknick, Jordan E.; Vorosmarty, Charles J.
Power plants that require cooling currently (2015) provide 85% of electricity generation in the United States. These facilities need large volumes of water and sufficiently cool temperatures for optimal operations, and projected climate conditions may lower their potential power output and affect reliability. We evaluate the performance of 1,080 thermoelectric plants across the contiguous US under future climates (2035-2064) and their collective performance at 19 North American Electric Reliability Corporation (NERC) sub-regions. Joint consideration of engineering interactions with climate, hydrology and environmental regulations reveals the region-specific performance of energy systems and the need for regional energy security and climate-water adaptationmore » strategies. Despite climate-water constraints on individual plants, the current power supply infrastructure shows potential for adaptation to future climates by capitalizing on the size of regional power systems, grid configuration and improvements in thermal efficiencies. Without placing climate-water impacts on individual plants in a broader power systems context, vulnerability assessments that aim to support adaptation and resilience strategies misgauge the extent to which regional energy systems are vulnerable. As a result, climate-water impacts can lower thermoelectric reserve margins, a measure of systems-level reliability, highlighting the need to integrate climate-water constraints on thermoelectric power supply into energy planning, risk assessments, and system reliability management.« less
Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.
Saner, Robert J; Washabaugh, Edward P; Krishnan, Chandramouli
2017-07-01
Three-dimensional (3-D) motion capture systems are commonly used for gait analysis because they provide reliable and accurate measurements. However, the downside of this approach is that it is expensive and requires technical expertise; thus making it less feasible in the clinic. To address this limitation, we recently developed and validated (using a high-precision walking robot) a low-cost, two-dimensional (2-D) real-time motion tracking approach using a simple webcam and LabVIEW Vision Assistant. The purpose of this study was to establish the repeatability and minimal detectable change values of hip and knee sagittal plane gait kinematics recorded using this system. Twenty-one healthy subjects underwent two kinematic assessments while walking on a treadmill at a range of gait velocities. Intraclass correlation coefficients (ICC) and minimal detectable change (MDC) values were calculated for commonly used hip and knee kinematic parameters to demonstrate the reliability of the system. Additionally, Bland-Altman plots were generated to examine the agreement between the measurements recorded on two different days. The system demonstrated good to excellent reliability (ICC>0.75) for all the gait parameters tested on this study. The MDC values were typically low (<5°) for most of the parameters. The Bland-Altman plots indicated that there was no systematic error or bias in kinematic measurements and showed good agreement between measurements obtained on two different days. These results indicate that kinematic gait assessments using webcam technology can be reliably used for clinical and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.
Harrop, James S; Vaccaro, Alexander R; Hurlbert, R John; Wilsey, Jared T; Baron, Eli M; Shaffrey, Christopher I; Fisher, Charles G; Dvorak, Marcel F; Oner, F C; Wood, Kirkham B; Anand, Neel; Anderson, D Greg; Lim, Moe R; Lee, Joon Y; Bono, Christopher M; Arnold, Paul M; Rampersaud, Y Raja; Fehlings, Michael G
2006-02-01
A new classification and treatment algorithm for thoracolumbar injuries was recently introduced by Vaccaro and colleagues in 2005. A thoracolumbar injury severity scale (TLISS) was proposed for grading and guiding treatment for these injuries. The scale is based on the following: 1) the mechanism of injury; 2) the integrity of the posterior ligamentous complex (PLC); and 3) the patient's neurological status. The reliability and validity of assessing injury mechanism and the integrity of the PLC was assessed. Forty-eight spine surgeons, consisting of neurosurgeons and orthopedic surgeons, reviewed 56 clinical thoracolumbar injury case histories. Each was classified and scored to determine treatment recommendations according to a novel classification system. After 3 months the case histories were reordered and the physicians repeated the exercise. Validity of this classification was good among reviewers; the vast majority (> 90%) agreed with the system's treatment recommendations. Surgeons were unclear as to a cogent description of PLC disruption and fracture mechanism. The TLISS demonstrated acceptable reliability in terms of intra- and interobserver agreement on the algorithm's treatment recommendations. Replacing injury mechanism with a description of injury morphology and better definition of PLC injury will improve inter- and intraobserver reliability of this injury classification system.
2014-01-01
Background A balance test provides important information such as the standard to judge an individual’s functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Methods Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). Results The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. Conclusion The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment. PMID:24912769
Park, Dae-Sung; Lee, GyuChang
2014-06-10
A balance test provides important information such as the standard to judge an individual's functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment.
The Consequences of Using One Assessment System to Pursue Two Objectives
ERIC Educational Resources Information Center
Neal, Derek
2013-01-01
Education officials often use one assessment system both to create measures of student achievement and to create performance metrics for educators. However, modern standardized testing systems are not designed to produce performance metrics for teachers or principals. They are designed to produce reliable measures of individual student achievement…
Electric service reliability cost/worth assessment in a developing country
NASA Astrophysics Data System (ADS)
Pandey, Mohan Kumar
Considerable work has been done in developed countries to optimize the reliability of electric power systems on the basis of reliability cost versus reliability worth. This has yet to be considered in most developing countries, where development plans are still based on traditional deterministic measures. The difficulty with these criteria is that they cannot be used to evaluate the economic impacts of changing reliability levels on the utility and the customers, and therefore cannot lead to an optimum expansion plan for the system. The critical issue today faced by most developing countries is that the demand for electric power is high and growth in supply is constrained by technical, environmental, and most importantly by financial impediments. Many power projects are being canceled or postponed due to a lack of resources. The investment burden associated with the electric power sector has already led some developing countries into serious debt problems. This thesis focuses on power sector issues facing by developing countries and illustrates how a basic reliability cost/worth approach can be used in a developing country to determine appropriate planning criteria and justify future power projects by application to the Nepal Integrated Electric Power System (NPS). A reliability cost/worth based system evaluation framework is proposed in this thesis. Customer surveys conducted throughout Nepal using in-person interviews with approximately 2000 sample customers are presented. The survey results indicate that the interruption cost is dependent on both customer and interruption characteristics, and it varies from one location or region to another. Assessments at both the generation and composite system levels have been performed using the customer cost data and the developed NPS reliability database. The results clearly indicate the implications of service reliability to the electricity consumers of Nepal, and show that the reliability cost/worth evaluation is both possible and practical in a developing country. The average customer interruption costs of Rs 35/kWh at Hierarchical Level I and Rs 26/kWh at Hierarchical Level II evaluated in this research work led to an optimum reserve margin of 7.5%, which is considerably lower than the traditional reserve margin of 15% used in the NPS. A similar conclusion may result in other developing countries facing difficulties in power system expansion planning using the traditional approach. A new framework for system planning is therefore recommended for developing countries which would permit an objective review of the traditional system planning approach, and the evaluation of future power projects using a new approach based on fundamental principles of power system reliability and economics.
Validation of a new classification system for skin tears.
LeBlanc, Kimberly; Baranoski, Sharon; Holloway, Samantha; Langemo, Diane
2013-06-01
The aim of this study was to validate and establish reliability of the International Skin Tear classification system. A consensus panel of 12 internationally recognized key opinion leaders convened in 2011 to establish consensus statements on the prevention, prediction, assessment, and treatment of skin tears. Subsequently, a new skin tear classification system was proposed. The system was then tested for interrater and intrarater reliability between the experts before being tested more widely on a sample of 327 individuals from the United States, Canada, and Europe. The results of the study indicated a substantial level of agreement for the expert panel (Fleiss κ = 0.619; 2-month follow-up = 0.653). Intrarater reliability was high (Cohen κ = 0.877). Interrater reliability was moderate (Fleiss κ = 0.555) for healthcare professionals (n = 303) and fair for non-health professionals (Fleiss κ = 0.338; n = 24). This international study established the reliability and validity of a new classification system for skin tears.
Validity and reliability of a pilot scale for assessment of multiple system atrophy symptoms.
Matsushima, Masaaki; Yabe, Ichiro; Takahashi, Ikuko; Hirotani, Makoto; Kano, Takahiro; Horiuchi, Kazuhiro; Houzen, Hideki; Sasaki, Hidenao
2017-01-01
Multiple system atrophy (MSA) is a rare progressive neurodegenerative disorder for which brief yet sensitive scale is required in order for use in clinical trials and general screening. We previously compared several scales for the assessment of MSA symptoms and devised an eight-item pilot scale with large standardized response mean [handwriting, finger taps, transfers, standing with feet together, turning trunk, turning 360°, gait, body sway]. The aim of the present study is to investigate the validity and reliability of a simple pilot scale for assessment of multiple system atrophy symptoms. Thirty-two patients with MSA (15 male/17 female; 20 cerebellar subtype [MSA-C]/12 parkinsonian subtype [MSA-P]) were prospectively registered between January 1, 2014 and February 28, 2015. Patients were evaluated by two independent raters using the Unified MSA Rating Scale (UMSARS), Scale for Assessment and Rating of Ataxia (SARA), and the pilot scale. Correlations between UMSARS, SARA, pilot scale scores, intraclass correlation coefficients (ICCs), and Cronbach's alpha coefficients were calculated. Pilot scale scores significantly correlated with scores for UMSARS Parts I, II, and IV as well as with SARA scores. Intra-rater and inter-rater ICCs and Cronbach's alpha coefficients remained high (> 0.94) for all measures. The results of the present study indicate the validity and reliability of the eight-item pilot scale, particularly for the assessment of symptoms in patients with early state multiple system atrophy.
Validation of a method for assessing resident physicians' quality improvement proposals.
Leenstra, James L; Beckman, Thomas J; Reed, Darcy A; Mundell, William C; Thomas, Kris G; Krajicek, Bryan J; Cha, Stephen S; Kolars, Joseph C; McDonald, Furman S
2007-09-01
Residency programs involve trainees in quality improvement (QI) projects to evaluate competency in systems-based practice and practice-based learning and improvement. Valid approaches to assess QI proposals are lacking. We developed an instrument for assessing resident QI proposals--the Quality Improvement Proposal Assessment Tool (QIPAT-7)-and determined its validity and reliability. QIPAT-7 content was initially obtained from a national panel of QI experts. Through an iterative process, the instrument was refined, pilot-tested, and revised. Seven raters used the instrument to assess 45 resident QI proposals. Principal factor analysis was used to explore the dimensionality of instrument scores. Cronbach's alpha and intraclass correlations were calculated to determine internal consistency and interrater reliability, respectively. QIPAT-7 items comprised a single factor (eigenvalue = 3.4) suggesting a single assessment dimension. Interrater reliability for each item (range 0.79 to 0.93) and internal consistency reliability among the items (Cronbach's alpha = 0.87) were high. This method for assessing resident physician QI proposals is supported by content and internal structure validity evidence. QIPAT-7 is a useful tool for assessing resident QI proposals. Future research should determine the reliability of QIPAT-7 scores in other residency and fellowship training programs. Correlations should also be made between assessment scores and criteria for QI proposal success such as implementation of QI proposals, resident scholarly productivity, and improved patient outcomes.
Robotic-Assisted Knee Arthroplasty: An Overview.
van der List, Jelle P; Chawla, Harshvardhan; Pearle, Andrew D
2016-01-01
Unicompartmental knee arthroplasty and total knee arthroplasty are reliable treatment options for osteoarthritis. In order to improve survivorship rates, variables that are intraoperatively controlled by the orthopedic surgeon are being evaluated. These variables include lower leg alignment, soft tissue balance, joint line maintenance, and tibial and femoral component alignment, size, and fixation methods. Since tighter control of these factors is associated with improved outcomes of knee arthroplasty, several computer-assisted surgery systems have been developed. These systems differ in the number and type of variables they control. Robotic-assisted systems control these aforementioned variables and, in addition, aim to improve the surgical precision of the procedure. Robotic-assisted systems are active, semi-active, or passive, depending on how independently the systems perform maneuvers. Reviewing the robotic-assisted knee arthroplasty systems, it becomes clear that these systems can accurately and reliably control the aforementioned variables. Moreover, these systems are more accurate and reliable in controlling these variables when compared to the current gold standard of conventional manual surgery. At present, few studies have assessed the survivorship and functional outcomes of robotic-assisted surgery, and no sufficiently powered studies were identified that compared survivorship or functional outcomes between robotic-assisted and conventional knee arthroplasty. Although preliminary outcomes of robotic-assisted surgery look promising, more studies are necessary to assess if the increased accuracy and reliability in controlling the surgical variables leads to better outcomes of robotic-assisted knee arthroplasty.
Comparing the reliability of related populations with the probability of agreement
Stevens, Nathaniel T.; Anderson-Cook, Christine M.
2016-07-26
Combining information from different populations to improve precision, simplify future predictions, or improve underlying understanding of relationships can be advantageous when considering the reliability of several related sets of systems. Using the probability of agreement to help quantify the similarities of populations can help to give a realistic assessment of whether the systems have reliability that are sufficiently similar for practical purposes to be treated as a homogeneous population. In addition, the new method is described and illustrated with an example involving two generations of a complex system where the reliability is modeled using either a logistic or probit regressionmore » model. Note that supplementary materials including code, datasets, and added discussion are available online.« less
Comparing the reliability of related populations with the probability of agreement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, Nathaniel T.; Anderson-Cook, Christine M.
Combining information from different populations to improve precision, simplify future predictions, or improve underlying understanding of relationships can be advantageous when considering the reliability of several related sets of systems. Using the probability of agreement to help quantify the similarities of populations can help to give a realistic assessment of whether the systems have reliability that are sufficiently similar for practical purposes to be treated as a homogeneous population. In addition, the new method is described and illustrated with an example involving two generations of a complex system where the reliability is modeled using either a logistic or probit regressionmore » model. Note that supplementary materials including code, datasets, and added discussion are available online.« less
Development of the Systems Thinking Scale for Adolescent Behavior Change.
Moore, Shirley M; Komton, Vilailert; Adegbite-Adeniyi, Clara; Dolansky, Mary A; Hardin, Heather K; Borawski, Elaine A
2018-03-01
This report describes the development and psychometric testing of the Systems Thinking Scale for Adolescent Behavior Change (STS-AB). Following item development, initial assessments of understandability and stability of the STS-AB were conducted in a sample of nine adolescents enrolled in a weight management program. Exploratory factor analysis of the 16-item STS-AB and internal consistency assessments were then done with 359 adolescents enrolled in a weight management program. Test-retest reliability of the STS-AB was .71, p = .03; internal consistency reliability was .87. Factor analysis of the 16-item STS-AB indicated a one-factor solution with good factor loadings, ranging from .40 to .67. Evidence of construct validity was supported by significant correlations with established measures of variables associated with health behavior change. We provide beginning evidence of the reliability and validity of the STS-AB to measure systems thinking for health behavior change in young adolescents.
Development of the Systems Thinking Scale for Adolescent Behavior Change
Moore, Shirley M.; Komton, Vilailert; Adegbite-Adeniyi, Clara; Dolansky, Mary A.; Hardin, Heather K.; Borawski, Elaine A.
2017-01-01
This report describes the development and psychometric testing of the Systems Thinking Scale for Adolescent Behavior Change (STS-AB). Following item development, initial assessments of understandability and stability of the STS-AB were conducted in a sample of nine adolescents enrolled in a weight management program. Exploratory factor analysis of the 16-item STS-AB and internal consistency assessments were then done with 359 adolescents enrolled in a weight management program. Test–retest reliability of the STS-AB was .71, p = .03; internal consistency reliability was .87. Factor analysis of the 16-item STS-AB indicated a one-factor solution with good factor loadings, ranging from .40 to .67. Evidence of construct validity was supported by significant correlations with established measures of variables associated with health behavior change. We provide beginning evidence of the reliability and validity of the STS-AB to measure systems thinking for health behavior change in young adolescents. PMID:28303755
NASA Astrophysics Data System (ADS)
Gao, Yi
The development and utilization of wind energy for satisfying electrical demand has received considerable attention in recent years due to its tremendous environmental, social and economic benefits, together with public support and government incentives. Electric power generation from wind energy behaves quite differently from that of conventional sources. The fundamentally different operating characteristics of wind energy facilities therefore affect power system reliability in a different manner than those of conventional systems. The reliability impact of such a highly variable energy source is an important aspect that must be assessed when the wind power penetration is significant. The focus of the research described in this thesis is on the utilization of state sampling Monte Carlo simulation in wind integrated bulk electric system reliability analysis and the application of these concepts in system planning and decision making. Load forecast uncertainty is an important factor in long range planning and system development. This thesis describes two approximate approaches developed to reduce the number of steps in a load duration curve which includes load forecast uncertainty, and to provide reasonably accurate generating and bulk system reliability index predictions. The developed approaches are illustrated by application to two composite test systems. A method of generating correlated random numbers with uniform distributions and a specified correlation coefficient in the state sampling method is proposed and used to conduct adequacy assessment in generating systems and in bulk electric systems containing correlated wind farms in this thesis. The studies described show that it is possible to use the state sampling Monte Carlo simulation technique to quantitatively assess the reliability implications associated with adding wind power to a composite generation and transmission system including the effects of multiple correlated wind sites. This is an important development as it permits correlated wind farms to be incorporated in large practical system studies without requiring excessive increases in computer solution time. The procedures described in this thesis for creating monthly and seasonal wind farm models should prove useful in situations where time period models are required to incorporate scheduled maintenance of generation and transmission facilities. There is growing interest in combining deterministic considerations with probabilistic assessment in order to evaluate the quantitative system risk and conduct bulk power system planning. A relatively new approach that incorporates deterministic and probabilistic considerations in a single risk assessment framework has been designated as the joint deterministic-probabilistic approach. The research work described in this thesis illustrates that the joint deterministic-probabilistic approach can be effectively used to integrate wind power in bulk electric system planning. The studies described in this thesis show that the application of the joint deterministic-probabilistic method provides more stringent results for a system with wind power than the traditional deterministic N-1 method because the joint deterministic-probabilistic technique is driven by the deterministic N-1 criterion with an added probabilistic perspective which recognizes the power output characteristics of a wind turbine generator.
Ball, Sarah C; Benjamin, Sara E; Ward, Dianne S
2007-04-01
To our knowledge, a direct observation protocol for assessing dietary intake among young children in child care has not been published. This article reviews the development and testing of a diet observation system for child care facilities that occurred during a larger intervention trial. Development of this system was divided into five phases, done in conjunction with a larger intervention study; (a) protocol development, (b) training of field staff, (c) certification of field staff in a laboratory setting, (d) implementation in a child-care setting, and (e) certification of field staff in a child-care setting. During the certification phases, methods were used to assess the accuracy and reliability of all observers at estimating types and amounts of food and beverages commonly served in child care. Tests of agreement show strong agreement among five observers, as well as strong accuracy between the observers and 20 measured portions of foods and beverages with a mean intraclass correlation coefficient value of 0.99. This structured observation system shows promise as a valid and reliable approach for assessing dietary intake of children in child care and makes a valuable contribution to the growing body of literature on the dietary assessment of young children.
Visconti, Luca; Martin, Conchita
2013-01-01
The aim of this study was to evaluate both intra- and interoperator reliability of a radiological three-dimensional classification system (KPG index) for the assessment of degree of difficulty for orthodontic treatment of maxillary canine impactions. Cone beam computed tomography (CBCT) scans of fifty impacted canines, obtained using three different scanners (NewTom, Kodak, and Planmeca), were classified using the KPG index by three independent orthodontists. Measurements were repeated one month later. Based on these two sessions, several recommendations on KPG Index scoring were elaborated. After a joint calibration session, these recommendations were explained to nine orthodontists and the two measurement sessions were repeated. There was a moderate intrarater agreement in the precalibration measurement sessions. After the calibration session, both intra- and interrater agreement were almost perfect. Indexes assessed with Kodak Dental Imaging 3D module software showed a better reliability in z-axis values, whereas indexes assessed with Planmeca Romexis software showed a better reliability in x- and y-axis values. No differences were found between the CBCT scanners used. Taken together, these findings indicate that the application of the instructions elaborated during this study improved KPG index reliability, which was nevertheless variously influenced by the use of different software for images evaluation. PMID:24235889
Mentiplay, Benjamin F; Perraton, Luke G; Bower, Kelly J; Pua, Yong-Hao; McGaw, Rebekah; Heywood, Sophie; Clark, Ross A
2015-07-16
The revised Xbox One Kinect, also known as the Microsoft Kinect V2 for Windows, includes enhanced hardware which may improve its utility as a gait assessment tool. This study examined the concurrent validity and inter-day reliability of spatiotemporal and kinematic gait parameters estimated using the Kinect V2 automated body tracking system and a criterion reference three-dimensional motion analysis (3DMA) marker-based camera system. Thirty healthy adults performed two testing sessions consisting of comfortable and fast paced walking trials. Spatiotemporal outcome measures related to gait speed, speed variability, step length, width and time, foot swing velocity and medial-lateral and vertical pelvis displacement were examined. Kinematic outcome measures including ankle flexion, knee flexion and adduction and hip flexion were examined. To assess the agreement between Kinect and 3DMA systems, Bland-Altman plots, relative agreement (Pearson's correlation) and overall agreement (concordance correlation coefficients) were determined. Reliability was assessed using intraclass correlation coefficients, Cronbach's alpha and standard error of measurement. The spatiotemporal measurements had consistently excellent (r≥0.75) concurrent validity, with the exception of modest validity for medial-lateral pelvis sway (r=0.45-0.46) and fast paced gait speed variability (r=0.73). In contrast kinematic validity was consistently poor to modest, with all associations between the systems weak (r<0.50). In those measures with acceptable validity, the inter-day reliability was similar between systems. In conclusion, while the Kinect V2 body tracking may not accurately obtain lower body kinematic data, it shows great potential as a tool for measuring spatiotemporal aspects of gait. Copyright © 2015 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Dorn, Fred J.; And Others
1983-01-01
Reviews the inconsistent findings of studies on neurolinguistic programing and recommends some areas that should be examined to verify various claims. Discusses methods of assessing client's primary representational systems, including predicate usage and eye movements, and suggests that more reliable methods of assessing PRS must be found. (JAC)
Measuring Teacher Effectiveness with the Pennsylvania Value-Added Assessment System
ERIC Educational Resources Information Center
Bowen, Naomi
2017-01-01
The purpose of this research was to determine if the Pennsylvania Value-Added Assessment System Average Growth Index (PVAAS AGI) scores, derived from standardized tests and calculated for Pennsylvania schools, provide a valid and reliable assessment of teacher effectiveness, as these scores are currently used to derive 15% of the annual…
Hamre, Charlotta; Botolfsen, Pernille; Tangen, Gro Gujord; Helbostad, Jorunn L
2017-04-20
The Balance Evaluation Systems Test (BESTest) was developed to assess underlying systems for balance control in order to be able to individually tailor rehabilitation interventions to people with balance disorders. A short form, the Mini-BESTest, was developed as a screening test. The study aimed to assess interrater and test-retest reliability of the Norwegian version of the BESTest and the Mini-BESTest in community-dwelling people with increased risk of falling and to assess concurrent validity with the Fall Efficacy Scale-International (FES-I), and it was an observational study with a cross-sectional design. Forty-two persons with increased risk of falling (elderly over 65 years of age, persons with a history of stroke or Multiple Sclerosis) were assessed twice by two raters. Relative reliability was analysed with Intraclass Correlation Coefficient (ICC), and absolute reliability with standard error of measurement (SEM) and smallest detectable change (SDC). Concurrent validity was assessed against the FES-I using Spearman's rho. The BESTest showed very good interrater reliability (ICC = 0.98, SEM = 1.79, SDC 95 = 5.0) and test-retest reliability (rater A/rater B = ICC = 0.89/0.89, SEM = 3.9/4.3, SDC 95 = 10.8/11.8). The Mini-BESTest also showed very good interrater reliability (ICC = 0.95, SEM = 1.19, SDC 95 = 3.3) and test-retest reliability (rater A/rater B = ICC = 0.85/0.84, SEM = 1.8/1.9, SDC 95 = 4.9/5.2). The correlations were moderate between the FES-I and both the BESTest and the Mini-BESTest (Spearman's rho -0.51 and-0.50, p < 0.01). The BESTest and its short form, the Mini-BESTest, showed very good interrater and test-retest reliability when assessed in a heterogeneous sample of people with increased risk of falling. The concurrent validity measured against the FES-I showed moderate correlation. The results are comparable with earlier studies and indicate that the Norwegian versions can be used in daily clinic and in research.
Reliability evaluation of microgrid considering incentive-based demand response
NASA Astrophysics Data System (ADS)
Huang, Ting-Cheng; Zhang, Yong-Jun
2017-07-01
Incentive-based demand response (IBDR) can guide customers to adjust their behaviour of electricity and curtail load actively. Meanwhile, distributed generation (DG) and energy storage system (ESS) can provide time for the implementation of IBDR. The paper focus on the reliability evaluation of microgrid considering IBDR. Firstly, the mechanism of IBDR and its impact on power supply reliability are analysed. Secondly, the IBDR dispatch model considering customer’s comprehensive assessment and the customer response model are developed. Thirdly, the reliability evaluation method considering IBDR based on Monte Carlo simulation is proposed. Finally, the validity of the above models and method is studied through numerical tests on modified RBTS Bus6 test system. Simulation results demonstrated that IBDR can improve the reliability of microgrid.
Reliable information on pipe condition is needed to accurately estimate the remaining service life of wastewater collection system assets. Although inspections with conventional closed-circuit television (CCTV) have been the mainstay of pipeline condition assessment for decades,...
Schutte, Jamie L; McCue, Michael P; Parmanto, Bambang; McGonigle, John; Handen, Benjamin; Lewis, Allen; Pulantara, I Wayan; Saptono, Andi
2015-03-01
The Autism Diagnostic Observation Schedule (ADOS) Module 4 is an autism assessment designed for verbally fluent adolescents and adults. Because of a shortage of available clinical expertise, it can be difficult for adults to receive a proper autism spectrum disorder (ASD) diagnostic assessment. A potential option to address this shortage is remote assessment. The objective of this study was to examine the feasibility, usability, and reliability of administering the ADOS Module 4 remotely using the Versatile and Integrated System for Telerehabilitation (VISYTER). VISYTER consists of computer stations at the client site and clinician site for video communication and a Web portal for managing and coordinating the assessment process. Twenty-three adults with an ASD diagnosis participated in a within-subject crossover design study in which both a remote ADOS and a face-to-face ADOS were administered. After completing the remote ADOS, participants completed a satisfaction survey. Participant satisfaction with the remote ADOS delivery system was high. The kappa value was greater than 0.61 on 21 of 31 ADOS items. There was substantial agreement on ADOS classification (i.e., diagnosis) between assessments delivered face-to-face versus assessments delivered remotely (interclass coefficient=0.92). Non-agreement may have been due to outside factors or practice effect despite a washout period. The results of this study demonstrate that an autism assessment designed to be delivered face to face can be administered remotely using an integrated Web-based system with high levels of usability and reliability.
NASA Astrophysics Data System (ADS)
Varlataya, S. K.; Evdokimov, V. E.; Urzov, A. Y.
2017-11-01
This article describes a process of calculating a certain complex information security system (CISS) reliability using the example of the technospheric security management model as well as ability to determine the frequency of its maintenance using the system reliability parameter which allows one to assess man-made risks and to forecast natural and man-made emergencies. The relevance of this article is explained by the fact the CISS reliability is closely related to information security (IS) risks. Since reliability (or resiliency) is a probabilistic characteristic of the system showing the possibility of its failure (and as a consequence - threats to the protected information assets emergence), it is seen as a component of the overall IS risk in the system. As it is known, there is a certain acceptable level of IS risk assigned by experts for a particular information system; in case of reliability being a risk-forming factor maintaining an acceptable risk level should be carried out by the routine analysis of the condition of CISS and its elements and their timely service. The article presents a reliability parameter calculation for the CISS with a mixed type of element connection, a formula of the dynamics of such system reliability is written. The chart of CISS reliability change is a S-shaped curve which can be divided into 3 periods: almost invariable high level of reliability, uniform reliability reduction, almost invariable low level of reliability. Setting the minimum acceptable level of reliability, the graph (or formula) can be used to determine the period of time during which the system would meet requirements. Ideally, this period should not be longer than the first period of the graph. Thus, the proposed method of calculating the CISS maintenance frequency helps to solve a voluminous and critical task of the information assets risk management.
NASA Technical Reports Server (NTRS)
Turnquist, S. R.; Twombly, M.; Hoffman, D.
1989-01-01
A preliminary reliability, availability, and maintainability (RAM) analysis of the proposed Space Station Freedom electric power system (EPS) was performed using the unit reliability, availability, and maintainability (UNIRAM) analysis methodology. Orbital replacement units (ORUs) having the most significant impact on EPS availability measures were identified. Also, the sensitivity of the EPS to variations in ORU RAM data was evaluated for each ORU. Estimates were made of average EPS power output levels and availability of power to the core area of the space station. The results of assessments of the availability of EPS power and power to load distribution points in the space stations are given. Some highlights of continuing studies being performed to understand EPS availability considerations are presented.
Akpinar, Pinar; Tezel, Canan G; Eliasson, Ann-Christin; Icagasioglu, Afitap
2010-01-01
To determine the reliability and cross-cultural validation of the Turkish translation of the Manual Ability Classification System (MACS) for children with cerebral palsy (CP) and to investigate the relation to gross motor function and other comorbidities. After the forward and backward translation procedures, inter-rater and test-retest reliability was assessed between parents, physiotherapists and physicians using the intra-class correlation coefficient (ICC). Children (N = 118, 4 to 18 years, mean age 9 years 4 months; 68 boys, 50 girls) with various types of CP were classified. Additional data on the Gross Motor Function Classification System (GMFCS), intellectual delay, visual acuity, and epilepsy were collected. The inter-rater reliability was high; the ICC ranged from 0.89 to 0.96 among different professionals and parents. Between two persons of the same profession it ranged from 0.97 to 0.98. For the test-retest reliability it ranged from 0.91 to 0.98. Total agreement between the GMFCS and the MACS occurred in only 45% of the children. The level of the MACS was found to correlate with the accompanying comorbidities, namely intellectual delay and epilepsy. The Turkish version of the MACS is found to be valid and reliable, and is suggested to be appropriate for the assessment of manual ability within the Turkish population.
NASA Astrophysics Data System (ADS)
Flanigan, Katherine A.; Johnson, Nephi R.; Hou, Rui; Ettouney, Mohammed; Lynch, Jerome P.
2017-04-01
The ability to quantitatively assess the condition of railroad bridges facilitates objective evaluation of their robustness in the face of hazard events. Of particular importance is the need to assess the condition of railroad bridges in networks that are exposed to multiple hazards. Data collected from structural health monitoring (SHM) can be used to better maintain a structure by prompting preventative (rather than reactive) maintenance strategies and supplying quantitative information to aid in recovery. To that end, a wireless monitoring system is validated and installed on the Harahan Bridge which is a hundred-year-old long-span railroad truss bridge that crosses the Mississippi River near Memphis, TN. This bridge is exposed to multiple hazards including scour, vehicle/barge impact, seismic activity, and aging. The instrumented sensing system targets non-redundant structural components and areas of the truss and floor system that bridge managers are most concerned about based on previous inspections and structural analysis. This paper details the monitoring system and the analytical method for the assessment of bridge condition based on automated data-driven analyses. Two primary objectives of monitoring the system performance are discussed: 1) monitoring fatigue accumulation in critical tensile truss elements; and 2) monitoring the reliability index values associated with sub-system limit states of these members. Moreover, since the reliability index is a scalar indicator of the safety of components, quantifiable condition assessment can be used as an objective metric so that bridge owners can make informed damage mitigation strategies and optimize resource management on single bridge or network levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, Tsong-Lun; Varuttamaseni, Athi; Baek, Joo-Seok
The U.S. Nuclear Regulatory Commission (NRC) encourages the use of probabilistic risk assessment (PRA) technology in all regulatory matters, to the extent supported by the state-of-the-art in PRA methods and data. Although much has been accomplished in the area of risk-informed regulation, risk assessment for digital systems has not been fully developed. The NRC established a plan for research on digital systems to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems in the PRAs of nuclear power plants (NPPs), and (2) incorporating digital systems in the NRC's risk-informed licensing and oversight activities.more » Under NRC's sponsorship, Brookhaven National Laboratory (BNL) explored approaches for addressing the failures of digital instrumentation and control (I and C) systems in the current NPP PRA framework. Specific areas investigated included PRA modeling digital hardware, development of a philosophical basis for defining software failure, and identification of desirable attributes of quantitative software reliability methods. Based on the earlier research, statistical testing is considered a promising method for quantifying software reliability. This paper describes a statistical software testing approach for quantifying software reliability and applies it to the loop-operating control system (LOCS) of an experimental loop of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL).« less
2011-09-01
a quality evaluation with limited data, a model -based assessment must be...that affect system performance, a multistage approach to system validation, a modeling and experimental methodology for efficiently addressing a ...affect system performance, a multistage approach to system validation, a modeling and experimental methodology for efficiently addressing a wide range
Digital avionics systems - Principles and practices (2nd revised and enlarged edition)
NASA Technical Reports Server (NTRS)
Spitzer, Cary R.
1993-01-01
The state of the art in digital avionics systems is surveyed. The general topics addressed include: establishing avionics system requirements; avionics systems essentials in data bases, crew interfaces, and power; fault tolerance, maintainability, and reliability; architectures; packaging and fitting the system into the aircraft; hardware assessment and validation; software design, assessment, and validation; determining the costs of avionics.
Clark, Ross A; Pua, Yong-Hao; Oliveira, Cristino C; Bower, Kelly J; Thilarajah, Shamala; McGaw, Rebekah; Hasanki, Ksaniel; Mentiplay, Benjamin F
2015-07-01
The Microsoft Kinect V2 for Windows, also known as the Xbox One Kinect, includes new and potentially far improved depth and image sensors which may increase its accuracy for assessing postural control and balance. The aim of this study was to assess the concurrent validity and reliability of kinematic data recorded using a marker-based three dimensional motion analysis (3DMA) system and the Kinect V2 during a variety of static and dynamic balance assessments. Thirty healthy adults performed two sessions, separated by one week, consisting of static standing balance tests under different visual (eyes open vs. closed) and supportive (single limb vs. double limb) conditions, and dynamic balance tests consisting of forward and lateral reach and an assessment of limits of stability. Marker coordinate and joint angle data were concurrently recorded using the Kinect V2 skeletal tracking algorithm and the 3DMA system. Task-specific outcome measures from each system on Day 1 and 2 were compared. Concurrent validity of trunk angle data during the dynamic tasks and anterior-posterior range and path length in the static balance tasks was excellent (Pearson's r>0.75). In contrast, concurrent validity for medial-lateral range and path length was poor to modest for all trials except single leg eyes closed balance. Within device test-retest reliability was variable; however, the results were generally comparable between devices. In conclusion, the Kinect V2 has the potential to be used as a reliable and valid tool for the assessment of some aspects of balance performance. Copyright © 2015 Elsevier B.V. All rights reserved.
Do aggressive signals evolve towards higher reliability or lower costs of assessment?
Ręk, P
2014-12-01
It has been suggested that the evolution of signals must be a wasteful process for the signaller, aimed at the maximization of signal honesty. However, the reliability of communication depends not only on the costs paid by signallers but also on the costs paid by receivers during assessment, and less attention has been given to the interaction between these two types of costs during the evolution of signalling systems. A signaller and receiver may accept some level of signal dishonesty by choosing signals that are cheaper in terms of assessment but that are stabilized with less reliable mechanisms. I studied the potential trade-off between signal reliability and the costs of signal assessment in the corncrake (Crex crex). I found that the birds prefer signals that are less costly regarding assessment rather than more reliable. Despite the fact that the fundamental frequency of calls was a strong predictor of male size, it was ignored by receivers unless they could directly compare signal variants. My data revealed a response advantage of costly signals when comparison between calls differing with fundamental frequencies is fast and straightforward, whereas cheap signalling is preferred in natural conditions. These data might improve our understanding of the influence of receivers on signal design because they support the hypothesis that fully honest signalling systems may be prone to dishonesty based on the effects of receiver costs and be replaced by signals that are cheaper in production and reception but more susceptible to cheating. © 2014 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2014 European Society For Evolutionary Biology.
Losa-Iglesias, Marta Elena; Becerro-de-Bengoa-Vallejo, Ricardo; Becerro-de-Bengoa-Losa, Klark Ricardo
2016-06-01
There are downloadable applications (Apps) for cell phones that can measure heart rate in a simple and painless manner. The aim of this study was to assess the reliability of this type of App for a Smartphone using an Android system, compared to the radial pulse and a portable pulse oximeter. We performed a pilot observational study of diagnostic accuracy, randomized in 46 healthy volunteers. The patients' demographic data and cardiac pulse were collected. Radial pulse was measured by palpation of the radial artery with three fingers at the wrist over the radius; a low-cost portable, liquid crystal display finger pulse oximeter; and a Heart Rate Plus for Samsung Galaxy Note®. This study demonstrated high reliability and consistency between systems with respect to the heart rate parameter of healthy adults using three systems. For all parameters, ICC was > 0.93, indicating excellent reliability. Moreover, CVME values for all parameters were between 1.66-4.06 %. We found significant correlation coefficients and no systematic differences between radial pulse palpation and pulse oximeter and a high precision. Low-cost pulse oximeter and App systems can serve as valid instruments for the assessment of heart rate in healthy adults. © The Author(s) 2014.
Validity and reliability of the Ergomopro powermeter.
Kirkland, A; Coleman, D; Wiles, J D; Hopker, J
2008-11-01
The aim of this investigation was to assess the validity and reliability of the Ergomopro powermeter. Nine participants completed trials on a Monark ergometer fitted with Ergomopro and SRM powermeters simultaneously recording power output. Each participant completed multiple trials at power outputs ranging from 50 to 450 W. The work stages recorded were 60 s in duration and were repeated three times. Participants also completed a single trial on a cycle ergometer designed to assess bilateral contributions to work output (Lode Excaliber Sport PFM). The power output during the trials was significantly different between all three systems, (p < 0.01) 231.2 +/- 114.2 W, 233.0 +/- 112.4 W, 227.8 +/- 108.8 W for the Monark, SRM and Ergomopro system, respectively. When the bilateral contributions were factored into the analysis, there were no significant differences between the powermeters (p = 0.58). The reliability of the Ergomopro system (CV%) was 2.31 % (95 % CI 2.13 - 2.52 %) compared to 1.59 % (95 % CI 1.47 to 1.74 %) for the Monark, and 1.37 % (95 % CI 1.26 - 1.50 %) for the SRM powermeter. These results indicate that the Ergomopro system has acceptable accuracy under these conditions. However, based on the reliability data, the increased variability of the Ergomopro system and bilateral balance issues have to be considered when using this device.
Evaluation of bus transit reliability in the District of Columbia.
DOT National Transportation Integrated Search
2013-11-01
Several performance metrics can be used to assess the reliability of a transit system. These include on-time arrivals, travel-time : adherence, run-time adherence, and customer satisfaction, among others. On-time arrival at bus stops is one of the pe...
Reliability and validity of the Microsoft Kinect for assessment of manual wheelchair propulsion.
Milgrom, Rachel; Foreman, Matthew; Standeven, John; Engsberg, Jack R; Morgan, Kerri A
2016-01-01
Concurrent validity and test-retest reliability of the Microsoft Kinect in quantification of manual wheelchair propulsion were examined. Data were collected from five manual wheelchair users on a roller system. Three Kinect sensors were used to assess test-retest reliability with a still pose. Three systems were used to assess concurrent validity of the Kinect to measure propulsion kinematics (joint angles, push loop characteristics): Kinect, Motion Analysis, and Dartfish ProSuite (Dartfish joint angles were limited to shoulder and elbow flexion). Intraclass correlation coefficients revealed good reliability (0.87-0.99) between five of the six joint angles (neck flexion, shoulder flexion, shoulder abduction, elbow flexion, wrist flexion). ICCs suggested good concurrent validity for elbow flexion between the Kinect and Dartfish and between the Kinect and Motion Analysis. Good concurrent validity was revealed for maximum height, hand-axle relationship, and maximum area (0.92-0.95) between the Kinect and Dartfish and maximum height and hand-axle relationship (0.89-0.96) between the Kinect and Motion Analysis. Analysis of variance revealed significant differences (p < 0.05) in maximum length between Dartfish (mean 58.76 cm) and the Kinect (40.16 cm). Results pose promising research and clinical implications for propulsion assessment and overuse injury prevention with the application of current findings to future technology.
On the reliable use of satellite-derived surface water products for global flood monitoring
NASA Astrophysics Data System (ADS)
Hirpa, F. A.; Revilla-Romero, B.; Thielen, J.; Salamon, P.; Brakenridge, R.; Pappenberger, F.; de Groeve, T.
2015-12-01
Early flood warning and real-time monitoring systems play a key role in flood risk reduction and disaster response management. To this end, real-time flood forecasting and satellite-based detection systems have been developed at global scale. However, due to the limited availability of up-to-date ground observations, the reliability of these systems for real-time applications have not been assessed in large parts of the globe. In this study, we performed comparative evaluations of the commonly used satellite-based global flood detections and operational flood forecasting system using 10 major flood cases reported over three years (2012-2014). Specially, we assessed the flood detection capabilities of the near real-time global flood maps from the Global Flood Detection System (GFDS), and from the Moderate Resolution Imaging Spectroradiometer (MODIS), and the operational forecasts from the Global Flood Awareness System (GloFAS) for the major flood events recorded in global flood databases. We present the evaluation results of the global flood detection and forecasting systems in terms of correctly indicating the reported flood events and highlight the exiting limitations of each system. Finally, we propose possible ways forward to improve the reliability of large scale flood monitoring tools.
Meaney, Calvin J; Arabi, Ziad; Venuto, Rocco C; Consiglio, Joseph D; Wilding, Gregory E; Tornatore, Kathleen M
2014-06-12
After renal transplantation, many patients experience adverse effects from maintenance immunosuppressive drugs. When these adverse effects occur, patient adherence with immunosuppression may be reduced and impact allograft survival. If these adverse effects could be prospectively monitored in an objective manner and possibly prevented, adherence to immunosuppressive regimens could be optimized and allograft survival improved. Prospective, standardized clinical approaches to assess immunosuppressive adverse effects by health care providers are limited. Therefore, we developed and evaluated the application, reliability and validity of a novel adverse effects scoring system in renal transplant recipients receiving calcineurin inhibitor (cyclosporine or tacrolimus) and mycophenolic acid based immunosuppressive therapy. The scoring system included 18 non-renal adverse effects organized into gastrointestinal, central nervous system and aesthetic domains developed by a multidisciplinary physician group. Nephrologists employed this standardized adverse effect evaluation in stable renal transplant patients using physical exam, review of systems, recent laboratory results, and medication adherence assessment during a clinic visit. Stable renal transplant recipients in two clinical studies were evaluated and received immunosuppressive regimens comprised of either cyclosporine or tacrolimus with mycophenolic acid. Face, content, and construct validity were assessed to document these adverse effect evaluations. Inter-rater reliability was determined using the Kappa statistic and intra-class correlation. A total of 58 renal transplant recipients were assessed using the adverse effects scoring system confirming face validity. Nephrologists (subject matter experts) rated the 18 adverse effects as: 3.1 ± 0.75 out of 4 (maximum) regarding clinical importance to verify content validity. The adverse effects scoring system distinguished 1.75-fold increased gastrointestinal adverse effects (p=0.008) in renal transplant recipients receiving tacrolimus and mycophenolic acid compared to the cyclosporine regimen. This finding demonstrated construct validity. Intra-class correlation was 0.81 (95% confidence interval: 0.65-0.90) and Kappa statistic of 0.68 ± 0.25 for all 18 adverse effects and verified substantial inter-rater reliability. This immunosuppressive adverse effects scoring system in stable renal transplant recipients was evaluated and substantiated face, content and construct validity with inter-rater reliability. The scoring system may facilitate prospective, standardized clinical monitoring of immunosuppressive adverse drug effects in stable renal transplant recipients and improve medication adherence.
Improvement of automatic control system for high-speed current collectors
NASA Astrophysics Data System (ADS)
Sidorov, O. A.; Goryunov, V. N.; Golubkov, A. S.
2018-01-01
The article considers the ways of regulation of pantographs to provide quality and reliability of current collection at high speeds. To assess impact of regulation was proposed integral criterion of the quality of current collection, taking into account efficiency and reliability of operation of the pantograph. The study was carried out using mathematical model of interaction of pantograph and catenary system, allowing to assess contact force and intensity of arcing at the contact zone at different movement speeds. The simulation results allowed us to estimate the efficiency of different methods of regulation of pantographs and determine the best option.
Reliability of sonographic assessment of tendinopathy in tennis elbow.
Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim
2012-01-01
To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.
R, Cuesta-Barriuso; A, Torres-Ortuño; S, Pérez-Alenda; J, Carrasco Juan; F, Querol; J, Nieto-Munuera; Ja, López-Pina
2018-02-27
Numerous measuring instruments for the evaluation of hemophilic arthropathy have been developed. One of the most used systems is the Hemophilia Joint Health Score (HJHS) given its sensitivity to clinical changes appearing in the joints because of recurrent hemarthrosis. Assessing the interrater reliability, using the Spanish version of the HJHS (version 2.1) in children with hemophilia. Reliability study to assess the interrater reliability of the Spanish version of HJHS. A sample of 36 children aged 7-13 years diagnosed with hemophilia A or B was used. Two physiotherapists performed physical assessments with the Spanish version of the HJHS. Descriptive statistics (range, mean, standard deviation) and the analysis of interrater reliability were calculated. The interrater reliability was heterogeneous since the Kappa coefficient range (ĸ), although significant (p < 0.001), ranged 0.31-1.00 in the variables of HJHS (swelling, duration of swelling, muscle atrophy, crepitus on motion, flexion loss, extension loss, joint pain, strength, and global gait). In assessing the bias of observers with the Bland and Altman method, the observer 1 scored 0.41 (CI [-0.67, 1.49]) units above observer 2, and the difference between the two was significant (t(36) = 4.48), p < 0.001). The interrater reliability of the Spanish population version of the HJHS is high. This scale should be used generically in evaluating musculoskeletal pediatric patients with hemophilia.
System reliability, performance and trust in adaptable automation.
Chavaillaz, Alain; Wastell, David; Sauer, Jürgen
2016-01-01
The present study examined the effects of reduced system reliability on operator performance and automation management in an adaptable automation environment. 39 operators were randomly assigned to one of three experimental groups: low (60%), medium (80%), and high (100%) reliability of automation support. The support system provided five incremental levels of automation which operators could freely select according to their needs. After 3 h of training on a simulated process control task (AutoCAMS) in which the automation worked infallibly, operator performance and automation management were measured during a 2.5-h testing session. Trust and workload were also assessed through questionnaires. Results showed that although reduced system reliability resulted in lower levels of trust towards automation, there were no corresponding differences in the operators' reliance on automation. While operators showed overall a noteworthy ability to cope with automation failure, there were, however, decrements in diagnostic speed and prospective memory with lower reliability. Copyright © 2015. Published by Elsevier Ltd.
Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen
2013-10-01
[Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86-0.99) for the elderly people and positive correlations (r = 0.58-0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability.
Lee, Eugene; Choi, Jung-Ah; Oh, Joo Han; Ahn, Soyeon; Hong, Sung Hwan; Chai, Jee Won; Kang, Heung Sik
2013-09-01
To retrospectively evaluate fatty degeneration (FD) of rotator cuff muscles on CTA using Goutallier's grading system and quantitative measurements with comparison between pre- and postoperative states. IRB approval was obtained for this study. Two radiologists independently reviewed pre- and postoperative CTAs of 43 patients (24 males and 19 females, mean age, 58.1 years) with 46 shoulders confirmed as full-thickness tears with random distribution. FD of supraspinatus, infraspinatus/teres minor, and subscapularis was assessed using Goutallier's system and by quantitative measurements of Hounsfield units (HUs) on sagittal images. Changes in FD grades and HUs were compared between pre- and postoperative CTAs and analyzed with respect to preoperative tear size and postoperative cuff integrity. The correlations between qualitative grades and quantitative measurements and their inter-observer reliabilities were also assessed. There was statistically significant correlation between FD grades and HU measurements of all muscles on pre- and postoperative CTA (p < 0.05). Inter-observer reliability of fatty degeneration grades were excellent to substantial on both pre- and postoperative CTA in supraspinatus (0.8685 and 0.8535) and subscapularis muscles (0.7777 and 0.7972), but fair in infraspinatus/teres minor muscles (0.5791 and 0.5740); however, quantitative Hounsfield units measurements showed excellent reliability for all muscles (ICC: 0.7950 and 0.9346 for SST, 0.7922 and 0.8492 for SSC, and 0.9254 and 0.9052 for IST/TM). No muscle showed improvement of fatty degeneration after surgical repair on qualitative and quantitative assessments; there was no difference in changes of fatty degeneration after surgical repair according to preoperative tear size and post-operative cuff integrity (p > 0.05). The average dose-length product (DLP, mGy · cm) was 365.2 mGy · cm (range, 323.8-417.2 mGy · cm) and estimated average effective dose was 5.1 mSv. Goutallier grades correlated well with HUs of rotator cuff muscles. Reliability was excellent for both systems, except for FD grade of IST/TM muscles, which may be more reliably assessed using quantitative measurements.
Maddali Bongi, S; Del Rosso, A; Miniati, I; Galluccio, F; Landi, G; Tai, G; Matucci-Cerinic, M
2012-09-01
In systemic sclerosis (SSc), mouth and face involvement leads to problems in oral health-related quality of life (OHRQoL). Mouth Handicap in Systemic Sclerosis scale (MHISS) is a 12-item questionnaire specifically quantifying mouth disability in SSc, organized in 3 subscales. Our aim was to validate Italian version of MHISS, by assessing its test-retest reliability and internal and external consistency in Italian SSc patients. Forty SSc patients (7 dSSc, 33 lSSc; age and disease duration: 57.27 ± 11.41, 9.4 ± 4.4 years; 22 with sicca syndrome) were evaluated with MHISS. MHISS was translated following a forward-backward translation procedure, with independent translations and counter-translation. Test-retest reliability was evaluated, comparing the results of two administrations, with intraclass correlation coefficient (ICC). Internal consistency was assessed by Cronbach's α and external consistency by comparison with mouth opening. MHISS has a good test-retest reliability (ICC: 0.93) and internal consistency (Cronbach's α:0.99). A good external consistency was confirmed by correlation with mouth opening (rho: -0,3869, p: 0.0137). Total MHISS score was 17.65 ± 5.20, with scores of subscale 1 (reduced mouth opening) of 6.60 ± 2.85 and scores of subscales 2 (sicca syndrome) and 3 (aesthetic concerns) of 7.82 ± 2.59 and 3.22 ± 1.14. Total and subscale 2 scores are higher in dSSc than in lSSc. This result may be due to the higher presence of sicca syndrome in dSSc than in lSSc (p = 0.0109). Our results support validity and reliability in Italian SSc patients of MHISS, specifically measuring SSc OHRQoL.
A Report on Simulation-Driven Reliability and Failure Analysis of Large-Scale Storage Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wan, Lipeng; Wang, Feiyi; Oral, H. Sarp
High-performance computing (HPC) storage systems provide data availability and reliability using various hardware and software fault tolerance techniques. Usually, reliability and availability are calculated at the subsystem or component level using limited metrics such as, mean time to failure (MTTF) or mean time to data loss (MTTDL). This often means settling on simple and disconnected failure models (such as exponential failure rate) to achieve tractable and close-formed solutions. However, such models have been shown to be insufficient in assessing end-to-end storage system reliability and availability. We propose a generic simulation framework aimed at analyzing the reliability and availability of storagemore » systems at scale, and investigating what-if scenarios. The framework is designed for an end-to-end storage system, accommodating the various components and subsystems, their interconnections, failure patterns and propagation, and performs dependency analysis to capture a wide-range of failure cases. We evaluate the framework against a large-scale storage system that is in production and analyze its failure projections toward and beyond the end of lifecycle. We also examine the potential operational impact by studying how different types of components affect the overall system reliability and availability, and present the preliminary results« less
The 20 GHz solid state transmitter design, impatt diode development and reliability assessment
NASA Technical Reports Server (NTRS)
Picone, S.; Cho, Y.; Asmus, J. R.
1984-01-01
A single drift gallium arsenide (GaAs) Schottky barrier IMPATT diode and related components were developed. The IMPATT diode reliability was assessed. A proof of concept solid state transmitter design and a technology assessment study were performed. The transmitter design utilizes technology which, upon implementation, will demonstrate readiness for development of a POC model within the 1982 time frame and will provide an information base for flight hardware capable of deployment in a 1985 to 1990 demonstrational 30/20 GHz satellite communication system. Life test data for Schottky barrier GaAs diodes and grown junction GaAs diodes are described. The results demonstrate the viability of GaAs IMPATTs as high performance, reliable RF power sources which, based on the recommendation made herein, will surpass device reliability requirements consistent with a ten year spaceborne solid state power amplifier mission.
The reliability of the Glasgow Coma Scale: a systematic review.
Reith, Florence C M; Van den Brande, Ruben; Synnot, Anneliese; Gruen, Russell; Maas, Andrew I R
2016-01-01
The Glasgow Coma Scale (GCS) provides a structured method for assessment of the level of consciousness. Its derived sum score is applied in research and adopted in intensive care unit scoring systems. Controversy exists on the reliability of the GCS. The aim of this systematic review was to summarize evidence on the reliability of the GCS. A literature search was undertaken in MEDLINE, EMBASE and CINAHL. Observational studies that assessed the reliability of the GCS, expressed by a statistical measure, were included. Methodological quality was evaluated with the consensus-based standards for the selection of health measurement instruments checklist and its influence on results considered. Reliability estimates were synthesized narratively. We identified 52 relevant studies that showed significant heterogeneity in the type of reliability estimates used, patients studied, setting and characteristics of observers. Methodological quality was good (n = 7), fair (n = 18) or poor (n = 27). In good quality studies, kappa values were ≥0.6 in 85%, and all intraclass correlation coefficients indicated excellent reliability. Poor quality studies showed lower reliability estimates. Reliability for the GCS components was higher than for the sum score. Factors that may influence reliability include education and training, the level of consciousness and type of stimuli used. Only 13% of studies were of good quality and inconsistency in reported reliability estimates was found. Although the reliability was adequate in good quality studies, further improvement is desirable. From a methodological perspective, the quality of reliability studies needs to be improved. From a clinical perspective, a renewed focus on training/education and standardization of assessment is required.
Smith, Justin D; Dishion, Thomas J; Brown, Kimbree; Ramos, Karina; Knoble, Naomi B; Shaw, Daniel S; Wilson, Melvin N
2016-01-01
The valid and reliable assessment of fidelity is critical at all stages of intervention research and is particularly germane to interpreting the results of efficacy and implementation trials. Ratings of protocol adherence typically are reliable, but ratings of therapist competence are plagued by low reliability. Because family context and case conceptualization guide the therapist's delivery of interventions, the reliability of fidelity ratings might be improved if the coder is privy to client context in the form of an ecological assessment. We conducted a randomized experiment to test this hypothesis. A subsample of 46 families with 5-year-old children from a multisite randomized trial who participated in the feedback session of the Family Check-Up (FCU) intervention were selected. We randomly assigned FCU feedback sessions to be rated for fidelity to the protocol using the COACH rating system either after the coder reviewed the results of a recent ecological assessment or had not. Inter-rater reliability estimates of fidelity ratings were meaningfully higher for the assessment information condition compared to the no-information condition. Importantly, the reliability of the COACH mean score was found to be statistically significantly higher in the information condition. These findings suggest that the reliability of observational ratings of fidelity, particularly when the competence or quality of delivery is considered, could be improved by providing assessment data to the coders. Our findings might be most applicable to assessment-driven interventions, where assessment data explicitly guides therapist's selection of intervention strategies tailored to the family's context and needs, but they could also apply to other intervention programs and observational coding of context-dependent therapy processes, such as the working alliance.
Smith, Justin D.; Dishion, Thomas J.; Brown, Kimbree; Ramos, Karina; Knoble, Naomi B.; Shaw, Daniel S.; Wilson, Melvin N.
2015-01-01
The valid and reliable assessment of fidelity is critical at all stages of intervention research and is particularly germane to interpreting the results of efficacy and implementation trials. Ratings of protocol adherence typically are reliable, but ratings of therapist competence are plagued by low reliability. Because family context and case conceptualization guide the therapist's delivery of interventions, the reliability of fidelity ratings might be improved if the coder is privy to client context in the form of an ecological assessment. We conducted a randomized experiment to test this hypothesis. A subsample of 46 families with 5-year-old children from a multisite randomized trial who participated in the feedback session of the Family Check-Up (FCU) intervention were selected. We randomly assigned FCU feedback sessions to be rated for fidelity to the protocol using the COACH rating system either after the coder reviewed the results of a recent ecological assessment or had not. Inter-rater reliability estimates of fidelity ratings were meaningfully higher for the assessment information condition compared to the no-information condition. Importantly, the reliability of the COACH mean score was found to be statistically significantly higher in the information condition. These findings suggest that the reliability of observational ratings of fidelity, particularly when the competence or quality of delivery is considered, could be improved by providing assessment data to the coders. Our findings might be most applicable to assessment-driven interventions, where assessment data explicitly guides therapist's selection of intervention strategies tailored to the family's context and needs, but they could also apply to other intervention programs and observational coding of context-dependent therapy processes, such as the working alliance. PMID:26271300
Ku-band signal design study. [space shuttle orbiter data processing network
NASA Technical Reports Server (NTRS)
Rubin, I.
1978-01-01
Analytical tools, methods and techniques for assessing the design and performance of the space shuttle orbiter data processing system (DPS) are provided. The computer data processing network is evaluated in the key areas of queueing behavior synchronization and network reliability. The structure of the data processing network is described as well as the system operation principles and the network configuration. The characteristics of the computer systems are indicated. System reliability measures are defined and studied. System and network invulnerability measures are computed. Communication path and network failure analysis techniques are included.
NASA Astrophysics Data System (ADS)
Kuznetsov, P. A.; Kovalev, I. V.; Losev, V. V.; Kalinin, A. O.; Murygin, A. V.
2016-04-01
The article discusses the reliability of automated control systems. Analyzes the approach to the classification systems for health States. This approach can be as traditional binary approach, operating with the concept of "serviceability", and other variants of estimation of the system state. This article provides one such option, providing selective evaluation of components for the reliability of the entire system. Introduced description of various automatic control systems and their elements from the point of view of health and risk, mathematical method of determining the transition object from state to state, they differ from each other in the implementation of the objective function. Explores the interplay of elements in different States, the aggregate state of the elements connected in series or in parallel. Are the tables of various logic States and the principles of their calculation in series and parallel connection. Through simulation the proposed approach is illustrated by finding the probability of getting into the system state data in parallel and serially connected elements, with their different probabilities of moving from state to state. In general, the materials of article will be useful for analyzing of the reliability the automated control systems and engineering of the highly-reliable systems. Thus, this mechanism to determine the State of the system provides more detailed information about it and allows a selective approach to the reliability of the system as a whole. Detailed results when assessing the reliability of the automated control systems allows the engineer to make an informed decision when designing means of improving reliability.
Sandia National Laboratories: Fabrication, Testing and Validation
; Technology Defense Systems & Assessments About Defense Systems & Assessments Program Areas safe, secure, reliable, and can fully support the Nation's deterrence policy. Employing only the most support of this mission, Sandia National Laboratories has a significant role in advancing the "state
Evaluation of Two Observational Assessment Systems for Children's Development and Learning
ERIC Educational Resources Information Center
Kim, Do-Hong; Smith, JaneDiane
2010-01-01
This study provided preliminary evidence for the reliability and validity of "Teaching Strategies GOLD", a recently developed observational system for assessing young children's development and learning. The measurement properties of "Teaching Strategies GOLD" were compared with those of an older instrument, "The Creative…
MEMS reliability: The challenge and the promise
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, W.M.; Tanner, D.M.; Miller, S.L.
1998-05-01
MicroElectroMechanical Systems (MEMS) that think, sense, act and communicate will open up a broad new array of cost effective solutions only if they prove to be sufficiently reliable. A valid reliability assessment of MEMS has three prerequisites: (1) statistical significance; (2) a technique for accelerating fundamental failure mechanisms, and (3) valid physical models to allow prediction of failures during actual use. These already exist for the microelectronics portion of such integrated systems. The challenge lies in the less well understood micromachine portions and its synergistic effects with microelectronics. This paper presents a methodology addressing these prerequisites and a description ofmore » the underlying physics of reliability for micromachines.« less
Application of reliability-centered-maintenance to BWR ECCS motor operator valve performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feltus, M.A.; Choi, Y.A.
1993-01-01
This paper describes the application of reliability-centered maintenance (RCM) methods to plant probabilistic risk assessment (PRA) and safety analyses for four boiling water reactor emergency core cooling systems (ECCSs): (1) high-pressure coolant injection (HPCI); (2) reactor core isolation cooling (RCIC); (3) residual heat removal (RHR); and (4) core spray systems. Reliability-centered maintenance is a system function-based technique for improving a preventive maintenance program that is applied on a component basis. Those components that truly affect plant function are identified, and maintenance tasks are focused on preventing their failures. The RCM evaluation establishes the relevant criteria that preserve system function somore » that an RCM-focused approach can be flexible and dynamic.« less
Reliability Assessment for Low-cost Unmanned Aerial Vehicles
NASA Astrophysics Data System (ADS)
Freeman, Paul Michael
Existing low-cost unmanned aerospace systems are unreliable, and engineers must blend reliability analysis with fault-tolerant control in novel ways. This dissertation introduces the University of Minnesota unmanned aerial vehicle flight research platform, a comprehensive simulation and flight test facility for reliability and fault-tolerance research. An industry-standard reliability assessment technique, the failure modes and effects analysis, is performed for an unmanned aircraft. Particular attention is afforded to the control surface and servo-actuation subsystem. Maintaining effector health is essential for safe flight; failures may lead to loss of control incidents. Failure likelihood, severity, and risk are qualitatively assessed for several effector failure modes. Design changes are recommended to improve aircraft reliability based on this analysis. Most notably, the control surfaces are split, providing independent actuation and dual-redundancy. The simulation models for control surface aerodynamic effects are updated to reflect the split surfaces using a first-principles geometric analysis. The failure modes and effects analysis is extended by using a high-fidelity nonlinear aircraft simulation. A trim state discovery is performed to identify the achievable steady, wings-level flight envelope of the healthy and damaged vehicle. Tolerance of elevator actuator failures is studied using familiar tools from linear systems analysis. This analysis reveals significant inherent performance limitations for candidate adaptive/reconfigurable control algorithms used for the vehicle. Moreover, it demonstrates how these tools can be applied in a design feedback loop to make safety-critical unmanned systems more reliable. Control surface impairments that do occur must be quickly and accurately detected. This dissertation also considers fault detection and identification for an unmanned aerial vehicle using model-based and model-free approaches and applies those algorithms to experimental faulted and unfaulted flight test data. Flight tests are conducted with actuator faults that affect the plant input and sensor faults that affect the vehicle state measurements. A model-based detection strategy is designed and uses robust linear filtering methods to reject exogenous disturbances, e.g. wind, while providing robustness to model variation. A data-driven algorithm is developed to operate exclusively on raw flight test data without physical model knowledge. The fault detection and identification performance of these complementary but different methods is compared. Together, enhanced reliability assessment and multi-pronged fault detection and identification techniques can help to bring about the next generation of reliable low-cost unmanned aircraft.
Inter-Observer Reliability of DSM-5 Substance Use Disorders*
Denis, Cécile M.; Gelernter, Joel; Hart, Amy B.; Kranzler, Henry R.
2015-01-01
Aims Although studies have examined the impact of changes made in DSM-5 on the estimated prevalence of substance use disorder (SUD) diagnoses, there is limited evidence of the reliability of DSM-5 SUDs. We evaluated the inter-observer reliability of four DSM-5 SUDs in a sample in which we had previously evaluated the reliability of DSM-IV diagnoses, allowing us to compare the two systems. Methods Two different interviewers each assessed 173 subjects over a 2-week period using the Semi-Structured Assessment for Drug Dependence and Alcoholism (SSADDA). Using the percent agreement and kappa (κ) coefficient, we examined the reliability of DSM-5 lifetime alcohol, opioid, cocaine, and cannabis use disorders, which we compared to that of SSADDA-derived DSM-IV SUD diagnoses. We also assessed the effect of additional lifetime SUD and lifetime mood or anxiety disorder diagnoses on the reliability of the DSM-5 SUD diagnoses. Results Reliability was good to excellent for the four disorders, with κ values ranging from 0.65 to 0.94. Agreement was consistently lower for SUDs of mild severity than for moderate or severe disorders. DSM-5 SUD diagnoses showed greater reliability than DSM-IV diagnoses of abuse or dependence or dependence only. Co-occurring SUD and lifetime mood or anxiety disorders exerted a modest effect on the reliability of the DSM-5 SUD diagnoses. Conclusions For alcohol, opioid, cocaine and cannabis use disorders, DSM-5 criteria and diagnoses are at least as reliable as those of DSM-IV. PMID:26048641
ERIC Educational Resources Information Center
Goclowski, John C.; And Others
The Reliability, Maintainability, and Cost Model (RMCM) described in this report is an interactive mathematical model with a built-in sensitivity analysis capability. It is a major component of the Life Cycle Cost Impact Model (LCCIM), which was developed as part of the DAIS advanced development program to be used to assess the potential impacts…
Thin-film reliability and engineering overview
NASA Technical Reports Server (NTRS)
Ross, R. G., Jr.
1984-01-01
The reliability and engineering technology base required for thin film solar energy conversions modules is discussed. The emphasis is on the integration of amorphous silicon cells into power modules. The effort is being coordinated with SERI's thin film cell research activities as part of DOE's Amorphous Silicon Program. Program concentration is on temperature humidity reliability research, glass breaking strength research, point defect system analysis, hot spot heating assessment, and electrical measurements technology.
Thin-film reliability and engineering overview
NASA Astrophysics Data System (ADS)
Ross, R. G., Jr.
1984-10-01
The reliability and engineering technology base required for thin film solar energy conversions modules is discussed. The emphasis is on the integration of amorphous silicon cells into power modules. The effort is being coordinated with SERI's thin film cell research activities as part of DOE's Amorphous Silicon Program. Program concentration is on temperature humidity reliability research, glass breaking strength research, point defect system analysis, hot spot heating assessment, and electrical measurements technology.
ERIC Educational Resources Information Center
Wray, Kraig; Lai, Cheng-Fei; Sáez, Leilani; Alonzo, Julie; Tindal, Gerald
2013-01-01
We report the results of an alternate form reliability and criterion validity study of kindergarten and grade 1 (N = 84-199) reading measures from the easyCBM© assessment system and Stanford Early School Achievement Test/Stanford Achievement Test, 10th edition (SESAT/SAT-10) across 5 time points. The alternate form reliabilities ranged from…
Reliability and Normative Data for the Dynamic Visual Acuity Test for Vestibular Screening.
Riska, Kristal M; Hall, Courtney D
2016-06-01
The purpose of this study was to determine reliability of computerized dynamic visual acuity (DVA) testing and to determine reference values for younger and older adults. A primary function of the vestibular system is to maintain gaze stability during head motion. The DVA test quantifies gaze stabilization with the head moving versus stationary. Commercially available computerized systems allow clinicians to incorporate DVA into their assessment; however, information regarding reliability and normative values of these systems is sparse. Forty-six healthy adults, grouped by age, with normal vestibular function were recruited. Each participant completed computerized DVA testing including static visual acuity, minimum perception time, and DVA using the NeuroCom inVision System. Testing was performed by two examiners in the same session and then repeated at a follow-up session 3 to 14 days later. Intraclass correlation coefficients (ICCs) were used to determine inter-rater and test-retest reliability. ICCs for inter-rater reliability ranged from 0.323 to 0.937 and from 0.434 to 0.909 for horizontal and vertical head movements, respectively. ICCs for test-retest reliability ranged from 0.154 to 0.856 and from 0.377 to 0.9062 for horizontal and vertical head movements, respectively. Overall, raw scores (left/right DVA and up/down DVA) were more reliable than DVA loss scores. Reliability of a commercially available DVA system has poor-to-fair reliability for DVA loss scores. The use of a convergence paradigm and not incorporating the forced choice paradigm may contribute to poor reliability.
NASA Astrophysics Data System (ADS)
Biryuk, V. V.; Tsapkova, A. B.; Larin, E. A.; Livshiz, M. Y.; Sheludko, L. P.
2018-01-01
A set of mathematical models for calculating the reliability indexes of structurally complex multifunctional combined installations in heat and power supply systems was developed. Reliability of energy supply is considered as required condition for the creation and operation of heat and power supply systems. The optimal value of the power supply system coefficient F is based on an economic assessment of the consumers’ loss caused by the under-supply of electric power and additional system expences for the creation and operation of an emergency capacity reserve. Rationing of RI of the industrial heat supply is based on the use of concept of technological margin of safety of technological processes. The definition of rationed RI values of heat supply of communal consumers is based on the air temperature level iside the heated premises. The complex allows solving a number of practical tasks for providing reliability of heat supply for consumers. A probabilistic model is developed for calculating the reliability indexes of combined multipurpose heat and power plants in heat-and-power supply systems. The complex of models and calculation programs can be used to solve a wide range of specific tasks of optimization of schemes and parameters of combined heat and power plants and systems, as well as determining the efficiency of various redundance methods to ensure specified reliability of power supply.
BILAG-2004 index captures systemic lupus erythematosus disease activity better than SLEDAI-2000.
Yee, C-S; Isenberg, D A; Prabu, A; Sokoll, K; Teh, L-S; Rahman, A; Bruce, I N; Griffiths, B; Akil, M; McHugh, N; D'Cruz, D; Khamashta, M A; Maddison, P; Zoma, A; Gordon, C
2008-06-01
To assess the reliability of Systemic Lupus Erythematosus Disease Activity Index (SLEDAI)-2000 index in routine practice and its ability to capture disease activity as compared with the British Isles Lupus Assessment Group (BILAG)-2004 index. Patients with systemic lupus erythematosus from 11 centres were assessed separately by two raters in routine practice. Disease activity was assessed using the BILAG-2004 and SLEDAI-2000 indices. The level of agreement for items was used to assess the reliability of SLEDAI-2000. The ability to detect disease activity was assessed by determining the number of patients with a high activity on BILAG-2004 (overall score A or B) but low SLEDAI-2000 score (<6) and number of patients with low activity on BILAG-2004 (overall score C, D or E) but high SLEDAI-2000 score (>or=6). Treatment of these patients was analysed, and the increase in treatment was used as the gold standard for active disease. 93 patients (90.3% women, 69.9% Caucasian) were studied: mean age was 43.8 years, mean disease duration 10 years. There were 43 patients (46.2%) with a difference in SLEDAI-2000 score between the two raters and this difference was >or=4 in 19 patients (20.4%). Agreement for each of the items in SLEDAI-2000 was between 81.7 and 100%. 35 patients (37.6%) had high activity on BILAG-2004 but a low SLEDAI-2000 score, of which 48.6% had treatment increased. There were only five patients (5.4%) with low activity on BILAG-2004 but a high SLEDAI-2000 score. SLEDAI-2000 is a reliable index to assess systemic lupus erythematosus disease activity but it is less able than the BILAG-2004 index to detect active disease requiring increased treatment.
Gao, Zhongyang; Song, Hui; Ren, Fenggang; Li, Yuhuan; Wang, Dong; He, Xijing
2017-12-01
The aim of the present study was to evaluate the reliability of the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion system in measuring the cervical range of motion (ROM) and verify the construct validity of the CODA motion system. A total of 26 patients with cervical spondylosis and 22 patients with anterior cervical fusion were enrolled and the CODA motion analysis system was used to measure the three-dimensional cervical ROM. Intra- and inter-rater reliability was assessed by interclass correlation coefficients (ICCs), standard error of measurement (SEm), Limits of Agreements (LOA) and minimal detectable change (MDC). Independent samples t-tests were performed to examine the differences of cervical ROM between cervical spondylosis and anterior cervical fusion patients. The results revealed that in the cervical spondylosis group, the reliability was almost perfect (intra-rater reliability: ICC, 0.87-0.95; LOA, -12.86-13.70; SEm, 2.97-4.58; inter-rater reliability: ICC, 0.84-0.95; LOA, -13.09-13.48; SEm, 3.13-4.32). In the anterior cervical fusion group, the reliability was high (intra-rater reliability: ICC, 0.88-0.97; LOA, -10.65-11.08; SEm, 2.10-3.77; inter-rater reliability: ICC, 0.86-0.96; LOA, -10.91-13.66; SEm, 2.20-4.45). The cervical ROM in the cervical spondylosis group was significantly higher than that in the anterior cervical fusion group in all directions except for left rotation. In conclusion, the CODA motion analysis system is highly reliable in measuring cervical ROM and the construct validity was verified, as the system was sufficiently sensitive to distinguish between the cervical spondylosis and anterior cervical fusion groups based on their ROM.
An overview of the mathematical and statistical analysis component of RICIS
NASA Technical Reports Server (NTRS)
Hallum, Cecil R.
1987-01-01
Mathematical and statistical analysis components of RICIS (Research Institute for Computing and Information Systems) can be used in the following problem areas: (1) quantification and measurement of software reliability; (2) assessment of changes in software reliability over time (reliability growth); (3) analysis of software-failure data; and (4) decision logic for whether to continue or stop testing software. Other areas of interest to NASA/JSC where mathematical and statistical analysis can be successfully employed include: math modeling of physical systems, simulation, statistical data reduction, evaluation methods, optimization, algorithm development, and mathematical methods in signal processing.
Savage, Jason W; Moore, Timothy A; Arnold, Paul M; Thakur, Nikhil; Hsu, Wellington K; Patel, Alpesh A; McCarthy, Kathryn; Schroeder, Gregory D; Vaccaro, Alexander R; Dimar, John R; Anderson, Paul A
2015-09-15
The thoracolumbar injury classification system (TLICS) was evaluated in 20 consecutive pediatric spine trauma cases. The purpose of this study was to determine the reliability and validity of the TLICS in pediatric spine trauma. The TLICS was developed to improve the categorization and management of thoracolumbar trauma. TLICS has been shown to have good reliability and validity in the adult population. The clinical and radiographical findings of 20 pediatric thoracolumbar fractures were prospectively presented to 20 surgeons with disparate levels of training and experience with spinal trauma. These injuries were consecutively scored using the TLICS. Cohen unweighted κ coefficients and Spearman rank order correlation values were calculated for the key parameters (injury morphology, status of posterior ligamentous complex, neurological status, TLICS total score, and proposed management) to assess the inter-rater reliabilities. Five surgeons scored the same cases 3 months later to assess the intra-rater reliability. The actual management of each case was then compared with the treatment recommended by the TLICS algorithm to assess validity. The inter-rater κ statistics of all subgroups (injury morphology, status of the posterior ligamentous complex, neurological status, TLICS total score, and proposed treatment) were within the range of moderate to substantial reproducibility (0.524-0.958). All subgroups had excellent intra-rater reliability (0.748-1.000). The various indices for validity were calculated (80.3% correct, 0.836 sensitivity, 0.785 specificity, 0.676 positive predictive value, 0.899 negative predictive value). Overall, TLICS demonstrated good validity. The TLICS has good reliability and validity when used in the pediatric population. The inter-rater reliability of predicting management and indices for validity are lower than those in adults with thoracolumbar fractures, which is likely due to differences in the way children are treated for certain types of injuries. TLICS can be used to reliably categorize thoracolumbar injuries in the pediatric population; however, modifications may be needed to better guide treatment in this specific patient population. 4.
Development of modelling algorithm of technological systems by statistical tests
NASA Astrophysics Data System (ADS)
Shemshura, E. A.; Otrokov, A. V.; Chernyh, V. G.
2018-03-01
The paper tackles the problem of economic assessment of design efficiency regarding various technological systems at the stage of their operation. The modelling algorithm of a technological system was performed using statistical tests and with account of the reliability index allows estimating the level of machinery technical excellence and defining the efficiency of design reliability against its performance. Economic feasibility of its application shall be determined on the basis of service quality of a technological system with further forecasting of volumes and the range of spare parts supply.
Mosmuller, David G M; Mennes, Lisette M; Prahl, Charlotte; Kramer, Gem J C; Disse, Melissa A; van Couwelaar, Gijs M; Niessen, Frank B; Griot, J P W Don
2017-09-01
The development of the Cleft Aesthetic Rating Scale, a simple and reliable photographic reference scale for the assessment of nasolabial appearance in complete unilateral cleft lip and palate patients. A blind retrospective analysis of photographs of cleft lip and palate patients was performed with this new rating scale. VU Medical Center Amsterdam and the Academic Center for Dentistry of Amsterdam. Complete unilateral cleft lip and palate patients at the age of 6 years. Photographs that showed the highest interobserver agreement in earlier assessments were selected for the photographic reference scale. Rules were attached to the rating scale to provide a guideline for the assessment and improve interobserver reliability. Cropped photographs revealing only the nasolabial area were assessed by six observers using this new Cleft Aesthetic Rating Scale in two different sessions. Photographs of 62 children (6 years of age, 44 boys and 18 girls) were assessed. The interobserver reliability for the nose and lip together was 0.62, obtained with the intraclass correlation coefficient. To measure the internal consistency, a Cronbach alpha of .91 was calculated. The estimated reliability for three observers was .84, obtained with the Spearman Brown formula. A new, easy to use, and reliable scoring system with a photographic reference scale is presented in this study.
Solar power satellite system definition study. Volume 1, phase 1: Executive summary
NASA Technical Reports Server (NTRS)
1979-01-01
A systems definition study of the solar satellite system (SPS) is presented. The technical feasibility of solar power satellites based on forecasts of technical capability in the various applicable technologies is assessed. The performance, cost, operational characteristics, reliability, and the suitability of SPS's as power generators for typical commercial electricity grids are discussed. The uncertainties inherent in the system characteristics forecasts are assessed.
Ahluwalia, Indu B; Helms, Kristen; Morrow, Brian
2013-01-01
We investigated the reliability and validity of three self-reported indicators from the Pregnancy Risk Assessment Monitoring System (PRAMS) survey. We used 2008 PRAMS (n=15,646) data from 12 states that had implemented the 2003 revised U.S. Certificate of Live Birth. We estimated reliability by kappa coefficient and validity by sensitivity and specificity using the birth certificate data as the reference for the following: prenatal participation in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC); Medicaid payment for delivery; and breastfeeding initiation. These indicators were examined across several demographic subgroups. The reliability was high for all three measures: 0.81 for WIC participation, 0.67 for Medicaid payment of delivery, and 0.72 for breastfeeding initiation. The validity of PRAMS indicators was also high: WIC participation (sensitivity = 90.8%, specificity = 90.6%), Medicaid payment for delivery (sensitivity = 82.4%, specificity = 85.6%), and breastfeeding initiation (sensitivity = 94.3%, specificity = 76.0%). The prevalence estimates were higher on PRAMS than the birth certificate for each of the indicators except Medicaid-paid delivery among non-Hispanic black women. Kappa values within most subgroups remained in the moderate range (0.40-0.80). Sensitivity and specificity values were lower for Hispanic women who responded to the PRAMS survey in Spanish and for breastfeeding initiation among women who delivered very low birthweight and very preterm infants. The validity and reliability of the PRAMS data for measures assessed were high. Our findings support the use of PRAMS data for epidemiological surveillance, research, and planning.
Rollover risk prediction of heavy vehicles by reliability index and empirical modelling
NASA Astrophysics Data System (ADS)
Sellami, Yamine; Imine, Hocine; Boubezoul, Abderrahmane; Cadiou, Jean-Charles
2018-03-01
This paper focuses on a combination of a reliability-based approach and an empirical modelling approach for rollover risk assessment of heavy vehicles. A reliability-based warning system is developed to alert the driver to a potential rollover before entering into a bend. The idea behind the proposed methodology is to estimate the rollover risk by the probability that the vehicle load transfer ratio (LTR) exceeds a critical threshold. Accordingly, a so-called reliability index may be used as a measure to assess the vehicle safe functioning. In the reliability method, computing the maximum of LTR requires to predict the vehicle dynamics over the bend which can be in some cases an intractable problem or time-consuming. With the aim of improving the reliability computation time, an empirical model is developed to substitute the vehicle dynamics and rollover models. This is done by using the SVM (Support Vector Machines) algorithm. The preliminary obtained results demonstrate the effectiveness of the proposed approach.
Fuller, Catherine J; Bladon, Bruce M; Driver, Adam J; Barr, Alistair R S
2006-03-01
The objective of this study was to assess the reliability of lameness scoring in horses. One veterinary surgeon examined nineteen lame horses on four occasions. Gait was recorded by camcorder, and scored from 0 to 10 ranging from sound to non-weight bearing lameness. A global score of overall change in lameness during the study was also determined for each horse. To measure intra-assessor reliability of the scoring systems, one veterinary surgeon scored videotapes of the horses' gaits on two occasions. To measure inter-assessor reliability, three veterinary surgeons viewed the videotapes, assigning individual lameness scores plus global scores to each horse. Reliability of individual lameness scoring was good intra-assessor, but only just within our acceptable limit inter-assessor. However, global scoring of change in lameness throughout the study was found to be reliable overall. Since clinician scoring is commonly used to assess lameness in horses, this is an important finding, fundamental to future clinical studies.
Data Applicability of Heritage and New Hardware for Launch Vehicle System Reliability Models
NASA Technical Reports Server (NTRS)
Al Hassan Mohammad; Novack, Steven
2015-01-01
Many launch vehicle systems are designed and developed using heritage and new hardware. In most cases, the heritage hardware undergoes modifications to fit new functional system requirements, impacting the failure rates and, ultimately, the reliability data. New hardware, which lacks historical data, is often compared to like systems when estimating failure rates. Some qualification of applicability for the data source to the current system should be made. Accurately characterizing the reliability data applicability and quality under these circumstances is crucial to developing model estimations that support confident decisions on design changes and trade studies. This presentation will demonstrate a data-source classification method that ranks reliability data according to applicability and quality criteria to a new launch vehicle. This method accounts for similarities/dissimilarities in source and applicability, as well as operating environments like vibrations, acoustic regime, and shock. This classification approach will be followed by uncertainty-importance routines to assess the need for additional data to reduce uncertainty.
Agreement, the F-Measure, and Reliability in Information Retrieval
Hripcsak, George; Rothschild, Adam S.
2005-01-01
Information retrieval studies that involve searching the Internet or marking phrases usually lack a well-defined number of negative cases. This prevents the use of traditional interrater reliability metrics like the κ statistic to assess the quality of expert-generated gold standards. Such studies often quantify system performance as precision, recall, and F-measure, or as agreement. It can be shown that the average F-measure among pairs of experts is numerically identical to the average positive specific agreement among experts and that κ approaches these measures as the number of negative cases grows large. Positive specific agreement—or the equivalent F-measure—may be an appropriate way to quantify interrater reliability and therefore to assess the reliability of a gold standard in these studies. PMID:15684123
NASA Astrophysics Data System (ADS)
Goh, A. T. C.; Kulhawy, F. H.
2005-05-01
In urban environments, one major concern with deep excavations in soft clay is the potentially large ground deformations in and around the excavation. Excessive movements can damage adjacent buildings and utilities. There are many uncertainties associated with the calculation of the ultimate or serviceability performance of a braced excavation system. These include the variabilities of the loadings, geotechnical soil properties, and engineering and geometrical properties of the wall. A risk-based approach to serviceability performance failure is necessary to incorporate systematically the uncertainties associated with the various design parameters. This paper demonstrates the use of an integrated neural network-reliability method to assess the risk of serviceability failure through the calculation of the reliability index. By first performing a series of parametric studies using the finite element method and then approximating the non-linear limit state surface (the boundary separating the safe and failure domains) through a neural network model, the reliability index can be determined with the aid of a spreadsheet. Two illustrative examples are presented to show how the serviceability performance for braced excavation problems can be assessed using the reliability index.
Alwan, Faris M; Baharum, Adam; Hassan, Geehan S
2013-01-01
The reliability of the electrical distribution system is a contemporary research field due to diverse applications of electricity in everyday life and diverse industries. However a few research papers exist in literature. This paper proposes a methodology for assessing the reliability of 33/11 Kilovolt high-power stations based on average time between failures. The objective of this paper is to find the optimal fit for the failure data via time between failures. We determine the parameter estimation for all components of the station. We also estimate the reliability value of each component and the reliability value of the system as a whole. The best fitting distribution for the time between failures is a three parameter Dagum distribution with a scale parameter [Formula: see text] and shape parameters [Formula: see text] and [Formula: see text]. Our analysis reveals that the reliability value decreased by 38.2% in each 30 days. We believe that the current paper is the first to address this issue and its analysis. Thus, the results obtained in this research reflect its originality. We also suggest the practicality of using these results for power systems for both the maintenance of power systems models and preventive maintenance models.
Alwan, Faris M.; Baharum, Adam; Hassan, Geehan S.
2013-01-01
The reliability of the electrical distribution system is a contemporary research field due to diverse applications of electricity in everyday life and diverse industries. However a few research papers exist in literature. This paper proposes a methodology for assessing the reliability of 33/11 Kilovolt high-power stations based on average time between failures. The objective of this paper is to find the optimal fit for the failure data via time between failures. We determine the parameter estimation for all components of the station. We also estimate the reliability value of each component and the reliability value of the system as a whole. The best fitting distribution for the time between failures is a three parameter Dagum distribution with a scale parameter and shape parameters and . Our analysis reveals that the reliability value decreased by 38.2% in each 30 days. We believe that the current paper is the first to address this issue and its analysis. Thus, the results obtained in this research reflect its originality. We also suggest the practicality of using these results for power systems for both the maintenance of power systems models and preventive maintenance models. PMID:23936346
Space station electrical power system availability study
NASA Technical Reports Server (NTRS)
Turnquist, Scott R.; Twombly, Mark A.
1988-01-01
ARINC Research Corporation performed a preliminary reliability, and maintainability (RAM) anlaysis of the NASA space station Electric Power Station (EPS). The analysis was performed using the ARINC Research developed UNIRAM RAM assessment methodology and software program. The analysis was performed in two phases: EPS modeling and EPS RAM assessment. The EPS was modeled in four parts: the insolar power generation system, the eclipse power generation system, the power management and distribution system (both ring and radial power distribution control unit (PDCU) architectures), and the power distribution to the inner keel PDCUs. The EPS RAM assessment was conducted in five steps: the use of UNIRAM to perform baseline EPS model analyses and to determine the orbital replacement unit (ORU) criticalities; the determination of EPS sensitivity to on-orbit spared of ORUs and the provision of an indication of which ORUs may need to be spared on-orbit; the determination of EPS sensitivity to changes in ORU reliability; the determination of the expected annual number of ORU failures; and the integration of the power generator system model results with the distribution system model results to assess the full EPS. Conclusions were drawn and recommendations were made.
NASA Technical Reports Server (NTRS)
Scheper, C.; Baker, R.; Frank, G.; Yalamanchili, S.; Gray, G.
1992-01-01
Systems for Space Defense Initiative (SDI) space applications typically require both high performance and very high reliability. These requirements present the systems engineer evaluating such systems with the extremely difficult problem of conducting performance and reliability trade-offs over large design spaces. A controlled development process supported by appropriate automated tools must be used to assure that the system will meet design objectives. This report describes an investigation of methods, tools, and techniques necessary to support performance and reliability modeling for SDI systems development. Models of the JPL Hypercubes, the Encore Multimax, and the C.S. Draper Lab Fault-Tolerant Parallel Processor (FTPP) parallel-computing architectures using candidate SDI weapons-to-target assignment algorithms as workloads were built and analyzed as a means of identifying the necessary system models, how the models interact, and what experiments and analyses should be performed. As a result of this effort, weaknesses in the existing methods and tools were revealed and capabilities that will be required for both individual tools and an integrated toolset were identified.
NASA Technical Reports Server (NTRS)
Bloomquist, C. E.; Kallmeyer, R. H.
1972-01-01
Field failure rates and confidence factors are presented for 88 identifiable components of the ground support equipment at the John F. Kennedy Space Center. For most of these, supplementary information regarding failure mode and cause is tabulated. Complete reliability assessments are included for three systems, eight subsystems, and nine generic piece-part classifications. Procedures for updating or augmenting the reliability results are also included.
Quantitative Accelerated Life Testing of MEMS Accelerometers
Bâzu, Marius; Gălăţeanu, Lucian; Ilian, Virgil Emil; Loicq, Jerome; Habraken, Serge; Collette, Jean-Paul
2007-01-01
Quantitative Accelerated Life Testing (QALT) is a solution for assessing the reliability of Micro Electro Mechanical Systems (MEMS). A procedure for QALT is shown in this paper and an attempt to assess the reliability level for a batch of MEMS accelerometers is reported. The testing plan is application-driven and contains combined tests: thermal (high temperature) and mechanical stress. Two variants of mechanical stress are used: vibration (at a fixed frequency) and tilting. Original equipment for testing at tilting and high temperature is used. Tilting is appropriate as application-driven stress, because the tilt movement is a natural environment for devices used for automotive and aerospace applications. Also, tilting is used by MEMS accelerometers for anti-theft systems. The test results demonstrated the excellent reliability of the studied devices, the failure rate in the “worst case” being smaller than 10-7h-1. PMID:28903265
Gelau, Christhard; Henning, Matthias J; Krems, Josef F
2009-03-01
In recent years considerable efforts have been spent on the development of the occlusion technique as a procedure for the assessment of the human-machine interface of in-vehicle information and communication systems (IVIS) designed to be used by the driver while driving. The importance and significance of the findings resulting from the application of this procedure depends essentially on its reliability. Because there is a lack of evidence as to whether this basic criterion of measurement is met with this procedure, and because questionable reliability can lead to doubts about their validity, our project strove to clarify this issue. This paper reports on a statistical reanalysis of data obtained from previous experiments. To summarise, the characteristic values found for internal consistency were almost all in the range of .90 for the occlusion technique, which can be considered satisfactory.
Duruöz, M T; Unal, C; Toprak, C Sanal; Sezer, I; Yilmaz, F; Ulutatar, F; Atagündüz, P; Baklacioglu, H S
2017-12-01
Background Systemic lupus erythematosus (SLE) may have a profound impact on quality of life. There is increasing interest in measuring quality of life in lupus patients. The purpose of this study was to investigate the validity and reliability of SLE Quality of Life Questionnaire (L-QoL) in Turkish SLE patients. Methods SLE according to 2012 Systemic Lupus International Collaborating Clinics Classification Criteria were recruited into the study. Demographic data, clinical parameters and disease activity measured with the Systemic Lupus Erythematosus Disease Activity Index-2000 (SLEDAI-2K); were noted. Nottingham Health Profile and Health Assessment Questionnaire were filled out in addition to the Turkish L-QoL (LQoL-TR). Internal consistency, test-retest reliability, and convergent and discriminant validity were evaluated. Results The mean age of participants was 43.55 ± 14.33 years and the mean disease duration was 89.8 ± 92.1 months. The patients filled out LQoL-TR in 2.5 min. Strong correlation of LQoL-TR with all subgroups of the Nottingham Health Profile and the Health Assessment Questionnaire were established showing the convergent validity. The highest correlation was demonstrated with emotional reactions (rho = 0.72) and sleep component (rho = 0.65) of the Nottingham Health Profile scale ( p < 0.0001). Its poor and not significant correlation with nonfunctional parameters (age, disease duration, perceived general health, SLEDAI-2K) showed its discriminative properties. LQoL-TR demonstrated good internal reliability with a Cronbach's α of 0.93 and test-retest reliability with intraclass correlation coefficient of 0.87. Conclusion The LQoL-TR is a practical and useful tool which demonstrates good validity and reliability.
Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.
2014-01-01
BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281
Maksymowych, Walter P; Cibere, Jolanda; Loeuille, Damien; Weber, Ulrich; Zubler, Veronika; Roemer, Frank W; Jaremko, Jacob L; Sayre, Eric C; Lambert, Robert G W
2014-02-01
Development of a validated magnetic resonance image (MRI) scoring system is essential in hip OA because radiographs are insensitive to change. We assessed the feasibility and reliability of 2 previously developed scoring methods: (1) the Hip Inflammation MRI Scoring System (HIMRISS) and (2) the Hip Osteoarthritis MRI Scoring System (HOAMS). Six readers (3 radiologists, 3 rheumatologists) participated in 2 reading exercises. In Reading Exercise 1, MRI of the hip of 20 subjects were read at a single time point followed by further standardization of methodology. In Reading Exercise 2, MRI of the hip of 18 subjects from a randomized controlled trial, assessed at 2 timepoints, and 27 subjects from a cross-sectional study were read for HIMRISS and HOAMS bone marrow lesions (BML) and synovitis. Reliability was assessed using intraclass correlation coefficient (ICC) and kappa statistics. Both methods were considered feasible. For Reading 1, HIMRISS ICC were 0.52, 0.61, 0.70, and 0.58 for femoral BML, acetabular BML, effusion, and total scores, respectively; and for HOAMS, summed BML and synovitis ICC were 0.52 and 0.46, respectively. For Reading 2, HIMRISS and HOAMS ICC for BML and synovitis-effusion improved substantially. Interobserver reliability for change scores was 0.81 and 0.71 for HIMRISS femoral and HOAMS summed BML, respectively. Responsiveness and discrimination was moderate to high for synovitis-effusion. Significant associations were noted between BML or synovitis scores and Western Ontario and McMaster Universities Osteoarthritis Index pain scores for baseline values (p ≤ 0.001). The BML and synovitis-effusion components of both HIMRISS and HOAMS scoring systems are feasible and reliable, and should be validated further.
Data Mining: A Systems Approach to Formative Assessment
ERIC Educational Resources Information Center
Schmid, Dale
2012-01-01
This article describes how using raw data and information from reliable assessments can inform teachers' decisions leading to improved instruction. The primary aim is to use a systems approach to provide evidence of what students know and how they demonstrate mastery. Such evidence can empower teachers to reach all students. The pedagogic…
Evaluating the Strength of School Tobacco Policies: The Development of a Practical Rating System
ERIC Educational Resources Information Center
Boyce, Jennifer C.; Mueller, Nancy B.; Hogan-Watts, Melissa; Luke, Douglas A.
2009-01-01
Background: School tobacco control policies vary widely in their strength, extensiveness, and enforcement. Currently, no standardized method exists to assess the comprehensiveness of school tobacco policies. The purpose of this study was to develop a new practical rating system for school tobacco policies, assess its reliability, and present…
Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen
2013-01-01
[Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86–0.99) for the elderly people and positive correlations (r = 0.58–0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability. PMID:24259769
Post-traumatic subtalar osteoarthritis: which grading system should we use?
de Muinck Keizer, Robert-Jan O; Backes, Manouk; Dingemans, Siem A; Goslings, J Carel; Schepers, Tim
2016-09-01
To assess and compare post-traumatic osteoarthritis following intra-articular calcaneal fractures, one must have a reliable grading system that consistently grades the post-traumatic changes of the joint. A reliable grading system aids in the communication between treating physicians and improves the interpretation of research. To date, there is no consensus on what grading system to use in the evaluation of post-traumatic subtalar osteoarthritis. The objective of this study was to determine and compare the inter- and intra-rater reliability of two grading systems for post-traumatic subtalar osteoarthritis. Four observers evaluated 50 calcaneal fractures at least one year after trauma on conventional oblique lateral, internally and externally rotated views, and graded post-traumatic subtalar osteoarthritis using the Kellgren and Lawrence Grading Scale (KLGS) and the Paley Grading System (PGS). Inter- and intra-rater reliability were calculated and compared. The inter-rater reliability showed an intra-class correlation (ICC) of 0.54 (95 % CI 0.40-0.67) for the KLGS and an ICC of 0.41 (95 % CI 0.26 - 0.57) for the PGS. This difference was not statistically significant. The intra-rater reliability showed a mean weighted kappa of 0.62 for both the KLGS and the PGS. There is no statistically significant difference in reliability between the Kellgren and Lawrence Grading System (KLGS) and the Paley Grading System (PGS). The PGS allows for an easy two-step approach making it easy for everyday clinical purposes. For research purposes however, the more detailed and widely used KLGS seems preferable.
NASA Technical Reports Server (NTRS)
Wallace, Dolores R.
2003-01-01
In FY01 we learned that hardware reliability models need substantial changes to account for differences in software, thus making software reliability measurements more effective, accurate, and easier to apply. These reliability models are generally based on familiar distributions or parametric methods. An obvious question is 'What new statistical and probability models can be developed using non-parametric and distribution-free methods instead of the traditional parametric method?" Two approaches to software reliability engineering appear somewhat promising. The first study, begin in FY01, is based in hardware reliability, a very well established science that has many aspects that can be applied to software. This research effort has investigated mathematical aspects of hardware reliability and has identified those applicable to software. Currently the research effort is applying and testing these approaches to software reliability measurement, These parametric models require much project data that may be difficult to apply and interpret. Projects at GSFC are often complex in both technology and schedules. Assessing and estimating reliability of the final system is extremely difficult when various subsystems are tested and completed long before others. Parametric and distribution free techniques may offer a new and accurate way of modeling failure time and other project data to provide earlier and more accurate estimates of system reliability.
Fernández-Lansac, Violeta; Crespo, María
2017-07-26
This study introduces a new coding system, the Coding and Assessment System for Narratives of Trauma (CASNOT), to analyse several language domains in narratives of autobiographical memories, especially in trauma narratives. The development of the coding system is described. It was applied to assess positive and traumatic/negative narratives in 50 battered women (trauma-exposed group) and 50 nontrauma-exposed women (control group). Three blind raters coded each narrative. Inter-rater reliability analyses were conducted for the CASNOT language categories (multirater Kfree coefficients) and dimensions (intraclass correlation coefficients). High levels of inter-rater agreement were found for most of the language domains. Categories that did not reach the expected reliability were mainly those related to cognitive processes, which reflects difficulties in operationalizing constructs such as lack of control or helplessness, control or planning, and rationalization or memory elaboration. Applications and limitations of the CASNOT are discussed to enhance narrative measures for autobiographical memories.
Arifin, Nooranida; Abu Osman, Noor Azuan; Wan Abas, Wan Abu Bakar
2014-04-01
The measurements of postural balance often involve measurement error, which affects the analysis and interpretation of the outcomes. In most of the existing clinical rehabilitation research, the ability to produce reliable measures is a prerequisite for an accurate assessment of an intervention after a period of time. Although clinical balance assessment has been performed in previous study, none has determined the intrarater test-retest reliability of static and dynamic stability indexes during dominant single stance. In this study, one rater examined 20 healthy university students (female=12, male=8) in two sessions separated by 7 day intervals. Three stability indexes--the overall stability index (OSI), anterior/posterior stability index (APSI), and medial/ lateral stability index (MLSI) in static and dynamic conditions--were measured during single dominant stance. Intraclass correlation coefficient (ICC), standard error measurement (SEM) and 95% confidence interval (95% CI) were calculated. Test-retest ICCs for OSI, APSI, and MLSI were 0.85, 0.78, and 0.84 during static condition and were 0.77, 0.77, and 0.65 during dynamic condition, respectively. We concluded that the postural stability assessment using Biodex stability system demonstrates good-to-excellent test-retest reliability over a 1 week time interval.
The report gives results of the development of new data that can be used to determine the effect of mineral oil contamination on the reliability of a heat pump system operating with a new hydrofluorocarbon mixture and polyol ester lubricant, to assess any performance degradation ...
Evaluation of air-displacement plethysmography for body composition assessment in preterm infants
USDA-ARS?s Scientific Manuscript database
Adiposity may contribute to the future risk of disease. The aim of this study was to evaluate the accuracy and reliability of an air-displacement plethysmography (ADP) system to estimate percentage fat mass (%FM) in preterm infants and to evaluate interdevice reliability in infants. A total of 70 pr...
Mosmuller, David G M; Maal, Thomas J; Prahl, Charlotte; Tan, Robin A; Mulder, Frans J; Schwirtz, Roderic M F; de Vet, Henrica C W; Bergé, Stefaan J; Don Griot, J P W
2017-08-01
For the assessment of the nasolabial appearance in cleft patients, a widely accepted, reliable scoring system is not available. In this study four different methods of assessment are compared, including 2D and 3D asymmetry and aesthetic assessments. The data and ratings from an earlier study using the Asher-McDade aesthetic index on 3D photographs and the outcomes of 3D facial distance mapping were compared to a 2D aesthetic assessment, the Cleft Aesthetic Rating Scale, and to SymNose, a computerized 2D asymmetry assessment technique. The reliability and correlation between the four assessment techniques were tested using a sample of 79 patients. The 3D asymmetry assessment had the highest reliability and could be performed by just one observer (Intraclass correlation coefficient (ICC): 0.99). The 2D asymmetry assessment of the nose was highly reliable when performed by just one observer (ICC: 0.89). However, for the 2D asymmetry assessment of the lip more observers were needed. For the 2D aesthetic assessments 3 observers were needed. The 3D aesthetic assessment had the lowest single-observer reliability (ICC: 0.38-0.56) of all four techniques. The agreement between the different assessment methods is poor to very poor. The highest correlation (R: 0.48) was found between 2D and 3D aesthetic assessments. Remarkably, the lowest correlations were found between 2D and 3D asymmetry assessments (0.08-0.17). Different assessment methods are not in agreement and seem to measure different nasolabial aspects. More research is needed to establish exactly what each assessment technique measures and which measurements or outcomes are relevant for the patients. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Risk-Based Probabilistic Approach to Aeropropulsion System Assessment
NASA Technical Reports Server (NTRS)
Tong, Michael T.
2002-01-01
In an era of shrinking development budgets and resources, where there is also an emphasis on reducing the product development cycle, the role of system assessment, performed in the early stages of an engine development program, becomes very critical to the successful development of new aeropropulsion systems. A reliable system assessment not only helps to identify the best propulsion system concept among several candidates, it can also identify which technologies are worth pursuing. This is particularly important for advanced aeropropulsion technology development programs, which require an enormous amount of resources. In the current practice of deterministic, or point-design, approaches, the uncertainties of design variables are either unaccounted for or accounted for by safety factors. This could often result in an assessment with unknown and unquantifiable reliability. Consequently, it would fail to provide additional insight into the risks associated with the new technologies, which are often needed by decision makers to determine the feasibility and return-on-investment of a new aircraft engine. In this work, an alternative approach based on the probabilistic method was described for a comprehensive assessment of an aeropropulsion system. The statistical approach quantifies the design uncertainties inherent in a new aeropropulsion system and their influences on engine performance. Because of this, it enhances the reliability of a system assessment. A technical assessment of a wave-rotor-enhanced gas turbine engine was performed to demonstrate the methodology. The assessment used probability distributions to account for the uncertainties that occur in component efficiencies and flows and in mechanical design variables. The approach taken in this effort was to integrate the thermodynamic cycle analysis embedded in the computer code NEPP (NASA Engine Performance Program) and the engine weight analysis embedded in the computer code WATE (Weight Analysis of Turbine Engines) with the fast probability integration technique (FPI). FPI was developed by Southwest Research Institute under contract with the NASA Glenn Research Center. The results were plotted in the form of cumulative distribution functions and sensitivity analyses and were compared with results from the traditional deterministic approach. The comparison showed that the probabilistic approach provides a more realistic and systematic way to assess an aeropropulsion system. The current work addressed the application of the probabilistic approach to assess specific fuel consumption, engine thrust, and weight. Similarly, the approach can be used to assess other aspects of aeropropulsion system performance, such as cost, acoustic noise, and emissions. Additional information is included in the original extended abstract.
Inter-observer reliability of DSM-5 substance use disorders.
Denis, Cécile M; Gelernter, Joel; Hart, Amy B; Kranzler, Henry R
2015-08-01
Although studies have examined the impact of changes made in DSM-5 on the estimated prevalence of substance use disorder (SUD) diagnoses, there is limited evidence concerning the reliability of DSM-5 SUDs. We evaluated the inter-observer reliability of four DSM-5 SUDs in a sample in which we had previously evaluated the reliability of DSM-IV diagnoses, allowing us to compare the two systems. Two different interviewers each assessed 173 subjects over a 2-week period using the Semi-Structured Assessment for Drug Dependence and Alcoholism (SSADDA). Using the percent agreement and kappa (κ) coefficient, we examined the reliability of DSM-5 lifetime alcohol, opioid, cocaine, and cannabis use disorders, which we compared to that of SSADDA-derived DSM-IV SUD diagnoses. We also assessed the effect of additional lifetime SUD and lifetime mood or anxiety disorder diagnoses on the reliability of the DSM-5 SUD diagnoses. Reliability was good to excellent for the four disorders, with κ values ranging from 0.65 to 0.94. Agreement was consistently lower for SUDs of mild severity than for moderate or severe disorders. DSM-5 SUD diagnoses showed greater reliability than DSM-IV diagnoses of abuse or dependence or dependence only. Co-occurring SUD and lifetime mood or anxiety disorders exerted a modest effect on the reliability of the DSM-5 SUD diagnoses. For alcohol, opioid, cocaine and cannabis use disorders, DSM-5 criteria and diagnoses are at least as reliable as those of DSM-IV. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Hotchkiss, David R; Aqil, Anwer; Lippeveld, Theo; Mukooyo, Edward
2010-07-03
Sound policy, resource allocation and day-to-day management decisions in the health sector require timely information from routine health information systems (RHIS). In most low- and middle-income countries, the RHIS is viewed as being inadequate in providing quality data and continuous information that can be used to help improve health system performance. In addition, there is limited evidence on the effectiveness of RHIS strengthening interventions in improving data quality and use. The purpose of this study is to evaluate the usefulness of the newly developed Performance of Routine Information System Management (PRISM) framework, which consists of a conceptual framework and associated data collection and analysis tools to assess, design, strengthen and evaluate RHIS. The specific objectives of the study are: a) to assess the reliability and validity of the PRISM instruments and b) to assess the validity of the PRISM conceptual framework. Facility- and worker-level data were collected from 110 health care facilities in twelve districts in Uganda in 2004 and 2007 using records reviews, structured interviews and self-administered questionnaires. The analysis procedures include Cronbach's alpha to assess internal consistency of selected instruments, test-retest analysis to assess the reliability and sensitivity of the instruments, and bivariate and multivariate statistical techniques to assess validity of the PRISM instruments and conceptual framework. Cronbach's alpha analysis suggests high reliability (0.7 or greater) for the indices measuring a promotion of a culture of information, RHIS tasks self-efficacy and motivation. The study results also suggest that a promotion of a culture of information influences RHIS tasks self-efficacy, RHIS tasks competence and motivation, and that self-efficacy and the presence of RHIS staff have a direct influence on the use of RHIS information, a key aspect of RHIS performance. The study results provide some empirical support for the reliability and validity of the PRISM instruments and the validity of the PRISM conceptual framework, suggesting that the PRISM approach can be effectively used by RHIS policy makers and practitioners to assess the RHIS and evaluate RHIS strengthening interventions. However, additional studies with larger sample sizes are needed to further investigate the value of the PRISM instruments in exploring the linkages between RHIS data quality and use, and health systems performance.
Strategic command, control, communications, and intelligence.
Zraket, C A
1984-06-22
Command, control, communications, and intelligence (C(3)l) for nuclear forces are essential elements in the deterrence of nuclear war. The present C(3)l) system has vulnerabilities associated with its reliability, survivability, and endurance under attack, thereby weakening deterrence by increasing the ambiguity in our capabilities. Development of a reliable and enduring C(3)l) system would reduce this ambiguity. Its reliable, positive control of nuclear forces would give the national leadership more time to assess situations, ensure discriminate retaliation, and improve our ability to manage crises in general. These capabilities could help to stop a war rapidly should one start. A reliable and enduring C(3)1) system will be needed for a long time to come, even if a freeze on strategic nuclear forces is accomplished or other arms control successes achieved. Indeed, C(3)l) may be the best source today of confidence-building measures to reduce tensions and the threat of nuclear catastrophe.
Bourret, A; Garant, D
2017-03-01
Quantitative genetics approaches, and particularly animal models, are widely used to assess the genetic (co)variance of key fitness related traits and infer adaptive potential of wild populations. Despite the importance of precision and accuracy of genetic variance estimates and their potential sensitivity to various ecological and population specific factors, their reliability is rarely tested explicitly. Here, we used simulations and empirical data collected from an 11-year study on tree swallow (Tachycineta bicolor), a species showing a high rate of extra-pair paternity and a low recruitment rate, to assess the importance of identity errors, structure and size of the pedigree on quantitative genetic estimates in our dataset. Our simulations revealed an important lack of precision in heritability and genetic-correlation estimates for most traits, a low power to detect significant effects and important identifiability problems. We also observed a large bias in heritability estimates when using the social pedigree instead of the genetic one (deflated heritabilities) or when not accounting for an important cause of resemblance among individuals (for example, permanent environment or brood effect) in model parameterizations for some traits (inflated heritabilities). We discuss the causes underlying the low reliability observed here and why they are also likely to occur in other study systems. Altogether, our results re-emphasize the difficulties of generalizing quantitative genetic estimates reliably from one study system to another and the importance of reporting simulation analyses to evaluate these important issues.
Yu, Ting Yue; Syeda, Fahima; Holmes, Andrew P; Osborne, Benjamin; Dehghani, Hamid; Brain, Keith L; Kirchhof, Paulus; Fabritz, Larissa
2014-08-01
We developed and validated a new optical mapping system for quantification of electrical activation and repolarisation in murine atria. The system makes use of a novel 2nd generation complementary metal-oxide-semiconductor (CMOS) camera with deliberate oversampling to allow both assessment of electrical activation with high spatial and temporal resolution (128 × 2048 pixels) and reliable assessment of atrial murine repolarisation using post-processing of signals. Optical recordings were taken from isolated, superfused and electrically stimulated murine left atria. The system reliably describes activation sequences, identifies areas of functional block, and allows quantification of conduction velocities and vectors. Furthermore, the system records murine atrial action potentials with comparable duration to both monophasic and transmembrane action potentials in murine atria. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Cheong, Sau Kuan; Lang, Cathryne P; Hemphill, Sheryl A; Johnston, Leanne M
2017-06-01
To evaluate the preliminary validity and reliability of the myTREEHOUSE Self-Concept Assessment for children with cerebral palsy (CP) aged 8 to 12 years. The myTREEHOUSE Self-Concept Assessment includes 26 items divided into eight domains, assessed across three Performance Perspectives (Personal, Social, and Perceived) and an additional Importance Rating. Face and content validity was assessed by semi-structured interviews with seven expert professionals regarding the assessment construct, content, and clinical utility. Reliability was assessed with 50 children aged 8 to 12 years with CP (29 males, 21 females; mean age 10y 2mo; Gross Motor Function Classification System [GMFCS] level I=35, II=8, III=5, IV=1; mean Wechsler Intelligence Scale for Children - Fourth Edition [WISC-IV]=104), whose data was used to calculate internal consistency of the scale, and a subset of 35 children (20 males, 15 females; mean age 10y 5mo; GMFCS level I=26, II=4, III=4, IV=1; mean WISC-IV=103) who participated in test-retest reliability within 14 to 28 days. Face and content validity was supported by positive expert feedback, with only minor adjustments suggested to clarify the wording of some items. After these amendments, strong internal consistency (Cronbach's α 0.84-0.91) and moderate to good test-retest reliability (intraclass correlation coefficient 0.64-0.75) was found for each component. The myTREEHOUSE Self-Concept Assessment is a valid and reliable assessment of self-concept for children with CP aged 8 to 12 years. © 2017 Mac Keith Press.
Nguyen, Anh-Dung; Boling, Michelle C; Slye, Carrie A; Hartley, Emily M; Parisi, Gina L
2013-01-01
Accurate, efficient, and reliable measurement methods are essential to prospectively identify risk factors for knee injuries in large cohorts. To determine tester reliability using digital photographs for the measurement of static lower extremity alignment (LEA) and whether values quantified with an electromagnetic motion-tracking system are in agreement with those quantified with clinical methods and digital photographs. Descriptive laboratory study. Laboratory. Thirty-three individuals participated and included 17 (10 women, 7 men; age = 21.7 ± 2.7 years, height = 163.4 ± 6.4 cm, mass = 59.7 ± 7.8 kg, body mass index = 23.7 ± 2.6 kg/m2) in study 1, in which we examined the reliability between clinical measures and digital photographs in 1 trained and 1 novice investigator, and 16 (11 women, 5 men; age = 22.3 ± 1.6 years, height = 170.3 ± 6.9 cm, mass = 72.9 ± 16.4 kg, body mass index = 25.2 ± 5.4 kg/m2) in study 2, in which we examined the agreement among clinical measures, digital photographs, and an electromagnetic tracking system. We evaluated measures of pelvic angle, quadriceps angle, tibiofemoral angle, genu recurvatum, femur length, and tibia length. Clinical measures were assessed using clinically accepted methods. Frontal- and sagittal-plane digital images were captured and imported into a computer software program. Anatomic landmarks were digitized using an electromagnetic tracking system to calculate static LEA. Intraclass correlation coefficients and standard errors of measurement were calculated to examine tester reliability. We calculated 95% limits of agreement and used Bland-Altman plots to examine agreement among clinical measures, digital photographs, and an electromagnetic tracking system. Using digital photographs, fair to excellent intratester (intraclass correlation coefficient range = 0.70-0.99) and intertester (intraclass correlation coefficient range = 0.75-0.97) reliability were observed for static knee alignment and limb-length measures. An acceptable level of agreement was observed between clinical measures and digital pictures for limb-length measures. When comparing clinical measures and digital photographs with the electromagnetic tracking system, an acceptable level of agreement was observed in measures of static knee angles and limb-length measures. The use of digital photographs and an electromagnetic tracking system appears to be an efficient and reliable method to assess static knee alignment and limb-length measurements.
Development of An Assessment Test for An Anesthetic Machine.
Tiviraj, Supinya; Yokubol, Bencharatana; Amornyotin, Somchai
2016-05-01
The study is aimed to develop and assess the quality of an evaluation form used to evaluate the nurse anesthetic trainees' skills in undertaking a pre-use check of an anesthetic machine. An evaluation form comprising 25 items was developed, informed by the guidelines published by national anesthesiologist societies and refined to reflect the anesthetic machine used in our institution. The item-checking included the cylinder supplies and medical gas pipelines, vaporizer back bar, ventilator anesthetic breathing system, scavenging system and emergency back-up equipment. The authors sought the opinions of five experienced anesthetic trainers to judge the validity of the content. The authors measured its inter-rater reliability when used by two achievement scores evaluating the performance of 36 nurse anesthetic trainees undertaking 15-minute anesthetic machine checks and test-retest the reliability correlation scores between the two performances in the seven days interval. The five experienced anesthesiologists agreed that the evaluation form accurately reflected the objectives of anesthetic machine checking, equating to an index of congruency of 1.00. The inter-rater reliability of the independent assessors scoring was 0.977 (p = 0.01) and the test-retest reliability was 0.883 (p = 0.01). An evaluation form proved to be a reliable and effective tool for assessing the anesthetic nurse trainees' checking of an anesthetic machine before the use. This evaluation form was brief clear and practical to use, and should help to improve anesthetic nurse education and the patient safety.
Mahmoud, Asmaa; Abundo, Paolo; Basile, Luisanna; Albensi, Caterina; Marasco, Morena; Bellizzi, Letizia; Galasso, Franco; Foti, Calogero
2017-01-01
In spite the instinct social&financial impact of Leg Length Discrepancy (LLD), controversial and conflicting results still exist regarding a reliable assessment/correction method. For proper management it's essential to discriminate between anatomical&functional Leg Length Discrepancy (FLLD). With the newly invented NPoS (New Postural Solution), under the umbrella of the collaboration of PRM Department, Tor Vergata University with Baro Postural Instruments srl, positive results were observed in both measuring& compensating the hemi-pelvic antero-medial rotation in FLLD through personalized bilateral heel raise using two NPoS components: Foot Image System (FIS) and Postural Optimizer System (POS). This led our research interest to test the validity of NPoS as a preliminary step before evaluating its implementations in postural disorders. After clinical evaluation, 4 subjects with FLLD have been assessed by NPoS. Over a period of 2 months, every subject was evaluated 12 times by two different operators, 48 measurements in total, results have been verified in correlation to BTS GaitLab results. Intra-Operator&inter-operator variability analysis showed statistically insignificant differences, while inter-method variability between NPoS and BTS parameters expressed a linear correlation. Results suggest a significant validity of NPoS in assessment&correction of FLLD, with high degree of reproducibility with minimal operator dependency. This can be considered a base for promising clinical implications of NPoS as a reliable cost effective postural assessment/corrective tool. V.
Assessing barriers to adherence in routine clinical care for pediatric kidney transplant patients.
Varnell, Charles D; Rich, Kristin L; Nichols, Melissa; Dahale, Devesh; Goebel, Jens W; Pai, Ahna L H; Hooper, David K; Modi, Avani C
2017-11-01
Patient-identified barriers to immunosuppressive medications are associated with poor adherence and negative clinical outcomes in transplant patients. Assessment of adherence barriers is not part of routine post-transplant care, and studies regarding implementing such a process in a reliable way are lacking. Using the Model for Improvement and PDSA cycles, we implemented a system to identify adherence barriers, including patient-centered design of a barriers assessment tool, identification of eligible patients, clear roles for clinic staff, and creating a culture of non-judgmental discussion around adherence. We performed time-series analysis of our process measure. Secondary analyses examined the endorsement and concordance of adherence barriers between patient-caregiver dyads. After three methods of testing, the most reliable delivery system was an EHR-integrated tablet that alerted staff of patient eligibility for assessment. Barriers were endorsed by 35% of caregivers (n=85) and 43% of patients (n=60). The most frequently patient-endorsed barriers were forgetting, poor taste, and side effects. Caregivers endorsed forgetting and side effects. Concordance between patient-caregiver dyads was fair (k=0.299). Standardized adherence barriers assessment is feasible in the clinical care of pediatric kidney transplant patients. Features necessary for success included automation, redundant systems with designated staff to identify and mitigate failures, aligned reporting structures, and reliable measurement approaches. Future studies will examine whether barriers predict clinical outcomes (eg, organ rejection, graft loss). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cachafeiro, Thais Hofmann; Escobar, Gabriela Fortes; Maldonado, Gabriela; Cestari, Tania Ferreira
2014-01-01
The "Quantitative Global Scarring Grading System for Postacne Scarring" was developed in English for acne scar grading, based on the number and severity of each type of scar. The aims of this study were to translate this scale into Brazilian Portuguese and verify its reliability and validity. The study followed five steps: Translation, Expert Panel, Back Translation, Approval of authors and Validation. The translated scale showed high internal consistency and high test-retest reliability, confirming its reproducibility. Therefore, it has been validated for our population and can be recommended as a reliable instrument to assess acne scarring. PMID:25184939
The Role of Assessment in a Response to Intervention Model
ERIC Educational Resources Information Center
Crawford, Lindy
2014-01-01
This article discusses the role of assessment in a response-to-intervention model. Although assessment represents only 1 component in a response-to-intervention model, a well-articulated assessment system is critical in providing teachers with reliable data that are easily interpreted and used to make instructional decisions. Three components of…
Cutolo, Maurizio; Vanhaecke, Amber; Ruaro, Barbara; Deschepper, Ellen; Ickinger, Claudia; Melsens, Karin; Piette, Yves; Trombetta, Amelia Chiara; De Keyser, Filip; Smith, Vanessa
2018-06-06
A reliable tool to evaluate flow is paramount in systemic sclerosis (SSc). We describe herein on the one hand a systematic literature review on the reliability of laser speckle contrast analysis (LASCA) to measure the peripheral blood perfusion (PBP) in SSc and perform an additional pilot study, investigating the intra- and inter-rater reliability of LASCA. A systematic search was performed in 3 electronic databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. In the pilot study, 30 SSc patients and 30 healthy subjects (HS) underwent LASCA assessment. Intra-rater reliability was assessed by having a first anchor rater performing the measurements at 2 time-points and inter-rater reliability by having the anchor rater and a team of second raters performing the measurements in 15 SSc and 30 HS. The measurements were repeated with a second anchor rater in the other 15 SSc patients, as external validation. Only 1 of the 14 records of interest identified through the systematic search was included in the final analysis. In the additional pilot study: intra-class correlation coefficient (ICC) for intra-rater reliability of the first anchor rater was 0.95 in SSc and 0.93 in HS, the ICC for inter-rater reliability was 0.97 in SSc and 0.93 in HS. Intra- and inter-rater reliability of the second anchor rater was 0.78 and 0.87. The identified literature regarding the reliability of LASCA measurements reports good to excellent inter-rater agreement. This very pilot study could confirm the reliability of LASCA measurements with good to excellent inter-rater agreement and found additionally good to excellent intra-rater reliability. Furthermore, similar results were found in the external validation. Copyright © 2018. Published by Elsevier B.V.
Fatigue Reliability of Gas Turbine Engine Structures
NASA Technical Reports Server (NTRS)
Cruse, Thomas A.; Mahadevan, Sankaran; Tryon, Robert G.
1997-01-01
The results of an investigation are described for fatigue reliability in engine structures. The description consists of two parts. Part 1 is for method development. Part 2 is a specific case study. In Part 1, the essential concepts and practical approaches to damage tolerance design in the gas turbine industry are summarized. These have evolved over the years in response to flight safety certification requirements. The effect of Non-Destructive Evaluation (NDE) methods on these methods is also reviewed. Assessment methods based on probabilistic fracture mechanics, with regard to both crack initiation and crack growth, are outlined. Limit state modeling techniques from structural reliability theory are shown to be appropriate for application to this problem, for both individual failure mode and system-level assessment. In Part 2, the results of a case study for the high pressure turbine of a turboprop engine are described. The response surface approach is used to construct a fatigue performance function. This performance function is used with the First Order Reliability Method (FORM) to determine the probability of failure and the sensitivity of the fatigue life to the engine parameters for the first stage disk rim of the two stage turbine. A hybrid combination of regression and Monte Carlo simulation is to use incorporate time dependent random variables. System reliability is used to determine the system probability of failure, and the sensitivity of the system fatigue life to the engine parameters of the high pressure turbine. 'ne variation in the primary hot gas and secondary cooling air, the uncertainty of the complex mission loading, and the scatter in the material data are considered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbert, B.G.; Richards, R.E.; Reece, W.J.
1992-10-01
This Reference Guide contains instructions on how to install and use Version 3.5 of the NRC-sponsored Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR). The NUCLARR data management system is contained in compressed files on the floppy diskettes that accompany this Reference Guide. NUCLARR is comprised of hardware component failure data (HCFD) and human error probability (HEP) data, both of which are available via a user-friendly, menu driven retrieval system. The data may be saved to a file in a format compatible with IRRAS 3.0 and commercially available statistical packages, or used to formulate log-plots and reports of data retrievalmore » and aggregation findings.« less
Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbert, B.G.; Richards, R.E.; Reece, W.J.
1992-10-01
This Reference Guide contains instructions on how to install and use Version 3.5 of the NRC-sponsored Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR). The NUCLARR data management system is contained in compressed files on the floppy diskettes that accompany this Reference Guide. NUCLARR is comprised of hardware component failure data (HCFD) and human error probability (HEP) data, both of which are available via a user-friendly, menu driven retrieval system. The data may be saved to a file in a format compatible with IRRAS 3.0 and commercially available statistical packages, or used to formulate log-plots and reports of data retrievalmore » and aggregation findings.« less
A Validation of the Classroom Assessment Scoring System in Finnish Kindergartens
ERIC Educational Resources Information Center
Pakarinen, Eija; Lerkkanen, Marja-Kristiina; Poikkeus, Anna-Maija; Kiuru, Noona; Siekkinen, Martti; Rasku-Puttonen, Helena; Nurmi, Jari-Erik
2010-01-01
Research Findings: This study examined the validity and reliability of the Classroom Assessment Scoring System (CLASS; R. C. Pianta, K. M. La Paro, & B. K. Hamre, 2008) in Finnish kindergartens. A pair of trained observers used the CLASS to observe 49 kindergarten teachers (47 female, 2 male) on two different days. Questionnaires measuring…
Rail Transit Fare Collection : Policy and Technology Assessment
DOT National Transportation Integrated Search
1982-12-01
In an attempt to resolve reliability problems, lower operation and maintenance costs, and simplify fare collection, transit authorities are focusing on their fare collection systems. Many transit properties have existing fare collection systems which...
Error assessment for emerging traffic data collection devices.
DOT National Transportation Integrated Search
2014-09-01
Providing accurate and reliable travel time information to roadway users is a critical part of Advanced Traffic Management Systems (ATMS) and : Advanced Travelers Information Systems (ATIS). Access to travel time information can significantly influen...
Validity and reliability of the BOD POD® S/T tracking system.
Tseh, W; Caputo, J L; Keefer, D J
2010-10-01
BOD POD(®) self-testing (S/T) body composition tracking system is a practical assessment tool designed for use in the health and fitness industries. Relative to its parent counterpart, the BOD POD(®) S/T has received little research attention. The primary purpose was to determine the validity of the BOD POD(®) S/T against hydrostatic weighing and 7-site skinfolds. Secondary aim was to determine the within-day and between-day reliability of the BOD POD(®) S/T. After a period of equipment and testing accommodation, volunteer's (N=50) body composition (%BF) via 7-site skinfolds, BOD POD(®) S/T, and hydrostatic weighing were obtained on the second and third visits. BOD POD(®) S/T significantly overestimated %BF when compared to hydrostatic weighing and 7-site skinfolds. There was no statistical difference between 7-site skinfolds and hydrostatic weighing values. BOD POD(®) S/T reliability within-day and between-days were high. While the BOD POD(®) S/T body composition tracking system is deemed reliable both within-day and between-days, it did significantly overestimate %BF in comparison to hydrostatic weighing and skinfolds. Future research should be aimed at deriving a correction factor for this body composition assessment tool. © Georg Thieme Verlag KG Stuttgart · New York.
2013-01-01
Background In recent years response rates on telephone surveys have been declining. Rates for the behavioral risk factor surveillance system (BRFSS) have also declined, prompting the use of new methods of weighting and the inclusion of cell phone sampling frames. A number of scholars and researchers have conducted studies of the reliability and validity of the BRFSS estimates in the context of these changes. As the BRFSS makes changes in its methods of sampling and weighting, a review of reliability and validity studies of the BRFSS is needed. Methods In order to assess the reliability and validity of prevalence estimates taken from the BRFSS, scholarship published from 2004–2011 dealing with tests of reliability and validity of BRFSS measures was compiled and presented by topics of health risk behavior. Assessments of the quality of each publication were undertaken using a categorical rubric. Higher rankings were achieved by authors who conducted reliability tests using repeated test/retest measures, or who conducted tests using multiple samples. A similar rubric was used to rank validity assessments. Validity tests which compared the BRFSS to physical measures were ranked higher than those comparing the BRFSS to other self-reported data. Literature which undertook more sophisticated statistical comparisons was also ranked higher. Results Overall findings indicated that BRFSS prevalence rates were comparable to other national surveys which rely on self-reports, although specific differences are noted for some categories of response. BRFSS prevalence rates were less similar to surveys which utilize physical measures in addition to self-reported data. There is very little research on reliability and validity for some health topics, but a great deal of information supporting the validity of the BRFSS data for others. Conclusions Limitations of the examination of the BRFSS were due to question differences among surveys used as comparisons, as well as mode of data collection differences. As the BRFSS moves to incorporating cell phone data and changing weighting methods, a review of reliability and validity research indicated that past BRFSS landline only data were reliable and valid as measured against other surveys. New analyses and comparisons of BRFSS data which include the new methodologies and cell phone data will be needed to ascertain the impact of these changes on estimates in the future. PMID:23522349
Sleeper, Mark D; Kenyon, Lisa K; Elliott, James M; Cheng, M Samuel
2016-12-01
Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts' USA-Gymnastics competitive level to calculate the coefficient of determination (r 2 ). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. The relationship between total MGFMT scores and subjects' current USA-Gymnastics competitive level was found to be good (r 2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level 3.
ERIC Educational Resources Information Center
Amrein-Beardsley, Audrey; Collins, Clarin
2012-01-01
The SAS Educational Value-Added Assessment System (SAS[R] EVAAS[R]) is the most widely used value-added system in the country. It is also self-proclaimed as "the most robust and reliable" system available, with its greatest benefit to help educators improve their teaching practices. This study critically examined the effects of SAS[R] EVAAS[R] as…
Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans; Søgaard, Karen
2014-10-01
The aims were to compile a schematic overview of clinical scapular assessment methods and critically appraise the methodological quality of the involved studies. A systematic, computer-assisted literature search using Medline, CINAHL, SportDiscus and EMBASE was performed from inception to October 2013. Reference lists in articles were also screened for publications. From 50 articles, 54 method names were identified and categorized into three groups: (1) Static positioning assessment (n = 19); (2) Semi-dynamic (n = 13); and (3) Dynamic functional assessment (n = 22). Fifteen studies were excluded for evaluation due to no/few clinimetric results, leaving 35 studies for evaluation. Graded according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN checklist), the methodological quality in the reliability and validity domains was "fair" (57%) to "poor" (43%), with only one study rated as "good". The reliability domain was most often investigated. Few of the assessment methods in the included studies that had "fair" or "good" measurement property ratings demonstrated acceptable results for both reliability and validity. We found a substantially larger number of clinical scapular assessment methods than previously reported. Using the COSMIN checklist the methodological quality of the included measurement properties in the reliability and validity domains were in general "fair" to "poor". None were examined for all three domains: (1) reliability; (2) validity; and (3) responsiveness. Observational evaluation systems and assessment of scapular upward rotation seem suitably evidence-based for clinical use. Future studies should test and improve the clinimetric properties, and especially diagnostic accuracy and responsiveness, to increase utility for clinical practice.
Hong, Tran Thi; Phuong Hoa, Nguyen; Walker, Sue M; Hill, Peter S; Rao, Chalapati
2018-01-01
Mortality statistics form a crucial component of national Health Management Information Systems (HMIS). However, there are limitations in the availability and quality of mortality data at national level in Viet Nam. This study assessed the completeness of recorded deaths and the reliability of recorded causes of death (COD) in the A6 death registers in the national routine HMIS in Viet Nam. 1477 identified deaths in 2014 were reviewed in two provinces. A capture-recapture method was applied to assess the completeness of the A6 death registers. 1365 household verbal autopsy (VA) interviews were successfully conducted, and these were reviewed by physicians who assigned multiple and underlying cause of death (UCOD). These UCODs from VA were then compared with the CODs recorded in the A6 death registers, using kappa scores to assess the reliability of the A6 death register diagnoses. The overall completeness of the A6 death registers in the two provinces was 89.3% (95%CI: 87.8-90.8). No COD recorded in the A6 death registers demonstrated good reliability. There is very low reliability in recording of cardiovascular deaths (kappa for stroke = 0.47 and kappa for ischaemic heart diseases = 0.42) and diabetes (kappa = 0.33). The reporting of deaths due to road traffic accidents, HIV and some cancers are at a moderate level of reliability with kappa scores ranging between 0.57-0.69 (p<0.01). VA methods identify more specific COD than the A6 death registers, and also allow identification of multiple CODs. The study results suggest that data completeness in HMIS A6 death registers in the study sample of communes was relatively high (nearly 90%), but triangulation with death records from other sources would improve the completeness of this system. Further, there is an urgent need to enhance the reliability of COD recorded in the A6 death registers, for which VA methods could be effective. Focussed consultation among stakeholders is needed to develop a suitable mechanism and process for integrating VA methods into the national routine HMIS A6 death registers in Viet Nam.
Ludwin, Artur; Ludwin, Inga; Kudla, Marek; Kottner, Jan
2015-09-01
To estimate the inter-rater/intrarater reliability of the European Society of Human Reproduction and Embryology/European Society for Gynaecological Endoscopy (ESHRE-ESGE) classification of congenital uterine malformations and to compare the results obtained with the reliability of the American Society for Reproductive Medicine (ASRM) classification supplemented with additional morphometric criteria. Reliability/agreement study. Private clinic. Uterine malformations (n = 50 patients, consecutively included) and normal uterus (n = 62 women, randomly selected) constituted the study. These were classified based on real-time three-dimensional ultrasound single volume transvaginal (or transrectal in the case of virgins, 4 cases) ultrasonography findings, which were assessed by an expert rater based on the ESHRE-ESGE criteria. The samples were obtained from women of reproductive age. Unprocessed three-dimensional datasets were independently evaluated offline by two experienced, blinded raters using both classification systems. The κ-values and proportions of agreement. Standardized interpretation indicated that the ESHRE-ESGE system has substantial/good or almost perfect/very good reliability (κ >0.60 and >0.80), but the interpretation of the clinically relevant cutoffs of κ-values showed insufficient reliability for clinical use (κ < 0.90), especially in the diagnosis of septate uterus. The ASRM system had sufficient reliability (κ > 0.95). The low reliability of the ESHRE-ESGE system may lead to a lack of consensus about the management of common uterine malformations and biased research interpretations. The use of the ASRM classification, supplemented with simple morphometric criteria, may be preferred if their sufficient reliability can be confirmed real-time in a large sample size. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Reliability analysis in the Office of Safety, Environmental, and Mission Assurance (OSEMA)
NASA Astrophysics Data System (ADS)
Kauffmann, Paul J.
1994-12-01
The technical personnel in the SEMA office are working to provide the highest degree of value-added activities to their support of the NASA Langley Research Center mission. Management perceives that reliability analysis tools and an understanding of a comprehensive systems approach to reliability will be a foundation of this change process. Since the office is involved in a broad range of activities supporting space mission projects and operating activities (such as wind tunnels and facilities), it was not clear what reliability tools the office should be familiar with and how these tools could serve as a flexible knowledge base for organizational growth. Interviews and discussions with the office personnel (both technicians and engineers) revealed that job responsibilities ranged from incoming inspection to component or system analysis to safety and risk. It was apparent that a broad base in applied probability and reliability along with tools for practical application was required by the office. A series of ten class sessions with a duration of two hours each was organized and scheduled. Hand-out materials were developed and practical examples based on the type of work performed by the office personnel were included. Topics covered were: Reliability Systems - a broad system oriented approach to reliability; Probability Distributions - discrete and continuous distributions; Sampling and Confidence Intervals - random sampling and sampling plans; Data Analysis and Estimation - Model selection and parameter estimates; and Reliability Tools - block diagrams, fault trees, event trees, FMEA. In the future, this information will be used to review and assess existing equipment and processes from a reliability system perspective. An analysis of incoming materials sampling plans was also completed. This study looked at the issues associated with Mil Std 105 and changes for a zero defect acceptance sampling plan.
Reliability analysis in the Office of Safety, Environmental, and Mission Assurance (OSEMA)
NASA Technical Reports Server (NTRS)
Kauffmann, Paul J.
1994-01-01
The technical personnel in the SEMA office are working to provide the highest degree of value-added activities to their support of the NASA Langley Research Center mission. Management perceives that reliability analysis tools and an understanding of a comprehensive systems approach to reliability will be a foundation of this change process. Since the office is involved in a broad range of activities supporting space mission projects and operating activities (such as wind tunnels and facilities), it was not clear what reliability tools the office should be familiar with and how these tools could serve as a flexible knowledge base for organizational growth. Interviews and discussions with the office personnel (both technicians and engineers) revealed that job responsibilities ranged from incoming inspection to component or system analysis to safety and risk. It was apparent that a broad base in applied probability and reliability along with tools for practical application was required by the office. A series of ten class sessions with a duration of two hours each was organized and scheduled. Hand-out materials were developed and practical examples based on the type of work performed by the office personnel were included. Topics covered were: Reliability Systems - a broad system oriented approach to reliability; Probability Distributions - discrete and continuous distributions; Sampling and Confidence Intervals - random sampling and sampling plans; Data Analysis and Estimation - Model selection and parameter estimates; and Reliability Tools - block diagrams, fault trees, event trees, FMEA. In the future, this information will be used to review and assess existing equipment and processes from a reliability system perspective. An analysis of incoming materials sampling plans was also completed. This study looked at the issues associated with Mil Std 105 and changes for a zero defect acceptance sampling plan.
Five-Segment Reusable Solid Rocket Booster Upgrade
NASA Technical Reports Server (NTRS)
Sauvageau, Don
1999-01-01
The Five Segment Reusable Solid Rocket Booster (RSRB) feasibility status is presented in viewgraph form. The Five Segment Booster (FSB) objective is to provide a low cost, low risk approach to increase reliability and safety of the Shuttle system. Topics include: booster upgrade requirements; design summary; reliability issues; booster trajectories; launch site assessment; and enhanced abort modes.
Detailed test plans : Evaluation of Utah Transit Authority Connection Protection system
DOT National Transportation Integrated Search
2003-10-31
The purpose of this evaluation is to assess the effectiveness of the Connection Protection (CP) system implemented by the Utah Transit Authority (UTA). The objective of the CP system is to improve the reliability of transfers from the higher frequenc...
Connors, Brenda L.; Rende, Richard; Colton, Timothy J.
2014-01-01
The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic – the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts – and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns. PMID:24999336
Connors, Brenda L; Rende, Richard; Colton, Timothy J
2014-01-01
The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic - the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts - and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns.
Koo, Henry; Leveridge, Mike; Thompson, Charles; Zdero, Rad; Bhandari, Mohit; Kreder, Hans J; Stephen, David; McKee, Michael D; Schemitsch, Emil H
2008-07-01
The purpose of this study was to measure interobserver reliability of 2 classification systems of pelvic ring fractures and to determine whether computed tomography (CT) improves reliability. The reliability of several radiographic findings was also tested. Thirty patients taken from a database at a Level I trauma facility were reviewed. For each patient, 3 radiographs (AP pelvis, inlet, and outlet) and CT scans were available. Six different reviewers (pelvic and acetabular specialist, orthopaedic traumatologist, or orthopaedic trainee) classified the injury according to Young-Burgess and Tile classification systems after reviewing plain radiographs and then after CT scans. The Kappa coefficient was used to determine interobserver reliability of these classification systems before and after CT scan. For plain radiographs, overall Kappa values for the Young-Burgess and Tile classification systems were 0.72 and 0.30, respectively. For CT scan and plain radiographs, the overall Kappa values for the Young-Burgess and Tile classification systems were 0.63 and 0.33, respectively. The pelvis/acetabular surgeons demonstrated the highest level of agreement using both classification systems. For individual questions, the addition of CT did significantly improve reviewer interpretation of fracture stability. The pre-CT and post-CT Kappa values for fracture stability were 0.59 and 0.93, respectively. The CT scan can improve the reliability of assessment of pelvic stability because of its ability to identify anatomical features of injury. The Young-Burgess system may be optimal for the learning surgeon. The Tile classification system is more beneficial for specialists in pelvic and acetabular surgery.
Methods for assessing the quality of data in public health information systems: a critical review.
Chen, Hong; Yu, Ping; Hailey, David; Wang, Ning
2014-01-01
The quality of data in public health information systems can be ensured by effective data quality assessment. In order to conduct effective data quality assessment, measurable data attributes have to be precisely defined. Then reliable and valid measurement methods for data attributes have to be used to measure each attribute. We conducted a systematic review of data quality assessment methods for public health using major databases and well-known institutional websites. 35 studies were eligible for inclusion in the study. A total of 49 attributes of data quality were identified from the literature. Completeness, accuracy and timeliness were the three most frequently assessed attributes of data quality. Most studies directly examined data values. This is complemented by exploring either data users' perception or documentation quality. However, there are limitations of current data quality assessment methods: a lack of consensus on attributes measured; inconsistent definition of the data quality attributes; a lack of mixed methods for assessing data quality; and inadequate attention to reliability and validity. Removal of these limitations is an opportunity for further improvement.
Survey of critical failure events in on-chip interconnect by fault tree analysis
NASA Astrophysics Data System (ADS)
Yokogawa, Shinji; Kunii, Kyousuke
2018-07-01
In this paper, a framework based on reliability physics is proposed for adopting fault tree analysis (FTA) to the on-chip interconnect system of a semiconductor. By integrating expert knowledge and experience regarding the possibilities of failure on basic events, critical issues of on-chip interconnect reliability will be evaluated by FTA. In particular, FTA is used to identify the minimal cut sets with high risk priority. Critical events affecting the on-chip interconnect reliability are identified and discussed from the viewpoint of long-term reliability assessment. The moisture impact is evaluated as an external event.
Bayesian Inference for NASA Probabilistic Risk and Reliability Analysis
NASA Technical Reports Server (NTRS)
Dezfuli, Homayoon; Kelly, Dana; Smith, Curtis; Vedros, Kurt; Galyean, William
2009-01-01
This document, Bayesian Inference for NASA Probabilistic Risk and Reliability Analysis, is intended to provide guidelines for the collection and evaluation of risk and reliability-related data. It is aimed at scientists and engineers familiar with risk and reliability methods and provides a hands-on approach to the investigation and application of a variety of risk and reliability data assessment methods, tools, and techniques. This document provides both: A broad perspective on data analysis collection and evaluation issues. A narrow focus on the methods to implement a comprehensive information repository. The topics addressed herein cover the fundamentals of how data and information are to be used in risk and reliability analysis models and their potential role in decision making. Understanding these topics is essential to attaining a risk informed decision making environment that is being sought by NASA requirements and procedures such as 8000.4 (Agency Risk Management Procedural Requirements), NPR 8705.05 (Probabilistic Risk Assessment Procedures for NASA Programs and Projects), and the System Safety requirements of NPR 8715.3 (NASA General Safety Program Requirements).
Toward extending the educational interpreter performance assessment to cued speech.
Krause, Jean C; Kegl, Judy A; Schick, Brenda
2008-01-01
The Educational Interpreter Performance Assessment (EIPA) is as an important research tool for examining the quality of interpreters who use American Sign Language or a sign system in classroom settings, but it is not currently applicable to educational interpreters who use Cued Speech (CS). In order to determine the feasibility of extending the EIPA to include CS, a pilot EIPA test was developed and administered to 24 educational CS interpreters. Fifteen of the interpreters' performances were evaluated two to three times in order to assess reliability. Results show that the instrument has good construct validity and test-retest reliability. Although more interrater reliability data are needed, intrarater reliability was quite high (0.9), suggesting that the pilot test can be rated as reliably as signing versions of the EIPA. Notably, only 48% of interpreters who formally participated in pilot testing performed at a level that could be considered minimally acceptable. In light of similar performance levels previously reported for interpreters who sign (e.g., Schick, Williams, & Kupermintz, 2006), these results suggest that interpreting services for deaf and hard-of hearing students, regardless of the communication option used, are often inadequate and could seriously hinder access to the classroom environment.
Toward Extending the Educational Interpreter Performance Assessment to Cued Speech
Krause, Jean C.; Kegl, Judy A.; Schick, Brenda
2008-01-01
The Educational Interpreter Performance Assessment (EIPA) is as an important research tool for examining the quality of interpreters who use American Sign Language or a sign system in classroom settings, but it is not currently applicable to educational interpreters who use Cued Speech (CS). In order to determine the feasibility of extending the EIPA to include CS, a pilot EIPA test was developed and administered to 24 educational CS interpreters. Fifteen of the interpreters’ performances were evaluated two to three times in order to assess reliability. Results show that the instrument has good construct validity and test–retest reliability. Although more interrater reliability data are needed, intrarater reliability was quite high (0.9), suggesting that the pilot test can be rated as reliably as signing versions of the EIPA. Notably, only 48% of interpreters who formally participated in pilot testing performed at a level that could be considered minimally acceptable. In light of similar performance levels previously reported for interpreters who sign (e.g., Schick, Williams, & Kupermintz, 2006), these results suggest that interpreting services for deaf and hard-of hearing students, regardless of the communication option used, are often inadequate and could seriously hinder access to the classroom environment. PMID:18042791
ERIC Educational Resources Information Center
Contino, Julie
2013-01-01
In a standards-based system, it is important for all components of the system to align in order to achieve the intended goals. No Child Left Behind law mandates that assessments be fully aligned with state standards, be valid, reliable and fair, be reported to all stakeholders, and provide evidence that all students in the state are meeting the…
NASA Technical Reports Server (NTRS)
Bloomquist, C. E.; Kallmeyer, R. H.
1972-01-01
Field failure rates and confidence factors are presented for 88 identifiable components of the ground support equipment at the John F. Kennedy Space Center. For most of these, supplementary information regarding failure mode and cause is tabulated. Complete reliability assessments are included for three systems, eight subsystems, and nine generic piece-part classifications. Procedures for updating or augmenting the reliability results presented in this handbook are also included.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graves, Todd L; Hamada, Michael S
2008-01-01
Good estimates of the reliability of a system make use of test data and expert knowledge at all available levels. Furthermore, by integrating all these information sources, one can determine how best to allocate scarce testing resources to reduce uncertainty. Both of these goals are facilitated by modern Bayesian computational methods. We apply these tools to examples that were previously solvable only through the use of ingenious approximations, and use genetic algorithms to guide resource allocation.
Ko, Jooyeon; Kim, MinYoung
2013-03-01
The Gross Motor Function Measure (GMFM-88) is commonly used in the evaluation of gross motor function in children with cerebral palsy (CP). The relative reliability of GMFM-88 has been assessed in children with CP. However, little information is available regarding the absolute reliability or responsiveness of GMFM-88. The purpose of this study was to determine the absolute and relative reliability and the responsiveness of the GMFM-88 in evaluating gross motor function in children with CP. A clinical measurement design was used. Ten raters scored the GMFM-88 in 84 children (mean age=3.7 years, SD=1.9, range=10 months to 9 years 9 months) from video records across all Gross Motor Function Classification System (GMFCS) levels to establish interrater reliability. Two raters participated to assess intrarater reliability. Responsiveness was determined from 3 additional assessments after the baseline assessment. The interrater and intrarater intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement (SEM), smallest real difference (SRD), effect size (ES), and standardized response mean (SRM) were calculated. The relative reliability of the GMFM was excellent (ICCs=.952-1.000). The SEM and SRD for total score of the GMFM were acceptable (1.60 and 3.14, respectively). Additionally, the ES and SRM of the dimension goal scores increased gradually in the 3 follow-up assessments (GMFCS levels I and II: ES=0.5, 0.6, and 0.8 and SRM=1.3, 1.8, and 2.0; GMFCS levels III-V: ES=0.4, 0.7, and 0.9 and SRM=1.5, 1.7, and 2.0). Children over 10 years of age with CP were not included in this study, so the results should not be generalized to all children with CP. Both the reliability and the responsiveness of the GMFM-88 are reasonable for measuring gross motor function in children with CP.
Reliable fusion of control and sensing in intelligent machines. Thesis
NASA Technical Reports Server (NTRS)
Mcinroy, John E.
1991-01-01
Although robotics research has produced a wealth of sophisticated control and sensing algorithms, very little research has been aimed at reliably combining these control and sensing strategies so that a specific task can be executed. To improve the reliability of robotic systems, analytic techniques are developed for calculating the probability that a particular combination of control and sensing algorithms will satisfy the required specifications. The probability can then be used to assess the reliability of the design. An entropy formulation is first used to quickly eliminate designs not capable of meeting the specifications. Next, a framework for analyzing reliability based on the first order second moment methods of structural engineering is proposed. To ensure performance over an interval of time, lower bounds on the reliability of meeting a set of quadratic specifications with a Gaussian discrete time invariant control system are derived. A case study analyzing visual positioning in robotic system is considered. The reliability of meeting timing and positioning specifications in the presence of camera pixel truncation, forward and inverse kinematic errors, and Gaussian joint measurement noise is determined. This information is used to select a visual sensing strategy, a kinematic algorithm, and a discrete compensator capable of accomplishing the desired task. Simulation results using PUMA 560 kinematic and dynamic characteristics are presented.
Fell, Matthew; Meirte, Jill; Anthonissen, Mieke; Maertens, Koen; Pleat, Jonathon; Moortgat, Peter
2016-03-01
Objective scar assessment tools were designed to help identify problematic scars and direct clinical management. Their use has been restricted by their measurement of a single scar property and the bulky size of equipment. The Scarbase Duo(®) was designed to assess both trans-epidermal water loss (TEWL) and colour of a burn scar whilst being compact and easy to use. Twenty patients with a burn scar were recruited and measurements taken using the Scarbase Duo(®) by two observers. The Scarbase Duo(®) measures TEWL via an open-chamber system and undertakes colorimetry via narrow-band spectrophotometry, producing values for relative erythema and melanin pigmentation. Validity was assessed by comparing the Scarbase Duo(®) against the Dermalab(®) and the Minolta Chromameter(®) respectively for TEWL and colorimetry measurements. The intra-class correlation coefficient (ICC) was used to assess reliability with standard error of measurement (SEM) used to assess reproducibility of measurements. The Pearson correlation coefficient (r) was used to assess the convergent validity. The Scarbase Duo(®) TEWL mode had excellent reliability when used on scars for both intra- (ICC=0.95) and inter-rater (ICC=0.96) measurements with moderate SEM values. The erythema component of the colorimetry mode showed good reliability for use on scars for both intra-(ICC=0.81) and inter-rater (ICC=0.83) measurements with low SEM values. Pigmentation values showed excellent reliability on scar tissue for both intra- (ICC=0.97) and inter-rater (ICC=0.97) with moderate SEM values. The Scarbase Duo(®) TEWL function had excellent correlation with the Dermalab(®) (r=0.93) whilst the colorimetry erythema value had moderate correlation with the Minolta Chromameter (r=0.72). The Scarbase Duo(®) is a reliable and objective scar assessment tool, which is specifically designed for burn scars. However, for clinical use, standardised measurement conditions are recommended. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Reliability and Validity Evidence of Multiple Balance Assessments in Athletes With a Concussion
Murray, Nicholas; Salvatore, Anthony; Powell, Douglas; Reed-Jones, Rebecca
2014-01-01
Context: An estimated 300 000 sport-related concussion injuries occur in the United States annually. Approximately 30% of individuals with concussions experience balance disturbances. Common methods of balance assessment include the Clinical Test of Sensory Organization and Balance (CTSIB), the Sensory Organization Test (SOT), the Balance Error Scoring System (BESS), and the Romberg test; however, the National Collegiate Athletic Association recommended the Wii Fit as an alternative measure of balance in athletes with a concussion. A central concern regarding the implementation of the Wii Fit is whether it is reliable and valid for measuring balance disturbance in athletes with concussion. Objective: To examine the reliability and validity evidence for the CTSIB, SOT, BESS, Romberg test, and Wii Fit for detecting balance disturbance in athletes with a concussion. Data Sources: Literature considered for review included publications with reliability and validity data for the assessments of balance (CTSIB, SOT, BESS, Romberg test, and Wii Fit) from PubMed, PsycINFO, and CINAHL. Data Extraction: We identified 63 relevant articles for consideration in the review. Of the 63 articles, 28 were considered appropriate for inclusion and 35 were excluded. Data Synthesis: No current reliability or validity information supports the use of the CTSIB, SOT, Romberg test, or Wii Fit for balance assessment in athletes with a concussion. The BESS demonstrated moderate to high reliability (interclass correlation coefficient = 0.87) and low to moderate validity (sensitivity = 34%, specificity = 87%). However, the Romberg test and Wii Fit have been shown to be reliable tools in the assessment of balance in Parkinson patients. Conclusions: The BESS can evaluate balance problems after a concussion. However, it lacks the ability to detect balance problems after the third day of recovery. Further investigation is needed to establish the use of the CTSIB, SOT, Romberg test, and Wii Fit for assessing balance in athletes with concussions. PMID:24933431
HIDECKER, MARY JO COOLEY; PANETH, NIGEL; ROSENBAUM, PETER L; KENT, RAYMOND D; LILLIE, JANET; EULENBERG, JOHN B; CHESTER, KEN; JOHNSON, BRENDA; MICHALSEN, LAUREN; EVATT, MORGAN; TAYLOR, KARA
2011-01-01
Aim The purpose of this study was to create and validate a Communication Function Classification System (CFCS) for children with cerebral palsy (CP) that can be used by a wide variety of individuals who are interested in CP. This paper reports the content validity, interrater reliability, and test–retest reliability of the CFCS for children with CP. Method An 11-member development team created comprehensive descriptions of the CFCS levels, and four nominal groups comprising 27 participants critiqued these levels. Within a Delphi survey, 112 participants commented on the clarity and usefulness of the CFCS. Interrater reliability was completed by 61 professionals and 68 parents/relatives who classified 69 children with CP aged 2 to 18 years. Test–retest reliability was completed by 48 professionals who allowed at least 2 weeks between classifications. The participants who assessed the CFCS were all relevant stakeholders: adults with CP, parents of children with CP, educators, occupational therapists, physical therapists, physicians, and speech–language pathologists. Results The interrater reliability of the CFCS was 0.66 between two professionals and 0.49 between a parent and a professional. Professional interrater reliability improved to 0.77 for classification of children older than 4 years. The test–retest reliability was 0.82. Interpretation The CFCS demonstrates content validity and shows very good test–retest reliability, good professional interrater reliability, and moderate parent–professional interrater reliability. Combining the CFCS with the Gross Motor Function Classification System and the Manual Ability Classification System contributes to a functional performance view of daily life for individuals with CP, in accordance with the World Health Organization’s International Classification of Functioning, Disability and Health. PMID:21707596
van der Laan, Tallie M J; Postema, Sietke G; Reneman, Michiel F; Bongers, Raoul M; van der Sluis, Corry K
2018-02-10
Reliability study. Quantifying compensatory movements during work-related tasks may help to prevent musculoskeletal complaints in individuals with upper limb absence. (1) To develop a qualitative scoring system for rating compensatory shoulder and trunk movements in upper limb prosthesis wearers during the performance of functional capacity evaluation tests adjusted for use by 1-handed individuals (functional capacity evaluation-one handed [FCE-OH]); (2) to examine the interrater and intrarater reliability of the scoring system; and (3) to assess its feasibility. Movement patterns of 12 videotaped upper limb prosthesis wearers and 20 controls were analyzed. Compensatory movements were defined for each FCE-OH test, and a scoring system was developed, pilot tested, and adjusted. During reliability testing, 18 raters (12 FCE experts and 6 physiotherapists/gait analysts) scored videotapes of upper limb prosthesis wearers performing 4 FCE-OH tests 2 times (2 weeks apart). Agreement was expressed in % and kappa value. Feasibility (focus area's "acceptability", "demand," and "implementation") was determined by using a questionnaire. After 2 rounds of pilot testing and adjusting, reliability of a third version was tested. The interrater reliability for the first and second rating sessions were к = 0.54 (confidence interval [CI]: 0.52-0.57) and к = 0.64 (CI: 0.61-0.66), respectively. The intrarater reliability was к = 0.77 (CI: 0.72-0.82). The feasibility was good but could be improved by a training program. It seems possible to identify compensatory movements in upper limb prosthesis wearers during the performance of FCE-OH tests reliably by observation using the developed observational scoring system. Interrater reliability was satisfactory in most instances; intrarater reliability was good. Feasibility was established. Copyright © 2018 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Reliability and Failure in NASA Missions: Blunders, Normal Accidents, High Reliability, Bad Luck
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2015-01-01
NASA emphasizes crew safety and system reliability but several unfortunate failures have occurred. The Apollo 1 fire was mistakenly unanticipated. After that tragedy, the Apollo program gave much more attention to safety. The Challenger accident revealed that NASA had neglected safety and that management underestimated the high risk of shuttle. Probabilistic Risk Assessment was adopted to provide more accurate failure probabilities for shuttle and other missions. NASA's "faster, better, cheaper" initiative and government procurement reform led to deliberately dismantling traditional reliability engineering. The Columbia tragedy and Mars mission failures followed. Failures can be attributed to blunders, normal accidents, or bad luck. Achieving high reliability is difficult but possible.
Human Reliability Assessments: Using the Past (Shuttle) to Predict the Future (Orion)
NASA Technical Reports Server (NTRS)
DeMott, Diana L.; Bigler, Mark A.
2017-01-01
NASA (National Aeronautics and Space Administration) Johnson Space Center (JSC) Safety and Mission Assurance (S&MA) uses two human reliability analysis (HRA) methodologies. The first is a simplified method which is based on how much time is available to complete the action, with consideration included for environmental and personal factors that could influence the human's reliability. This method is expected to provide a conservative value or placeholder as a preliminary estimate. This preliminary estimate or screening value is used to determine which placeholder needs a more detailed assessment. The second methodology is used to develop a more detailed human reliability assessment on the performance of critical human actions. This assessment needs to consider more than the time available, this would include factors such as: the importance of the action, the context, environmental factors, potential human stresses, previous experience, training, physical design interfaces, available procedures/checklists and internal human stresses. The more detailed assessment is expected to be more realistic than that based primarily on time available. When performing an HRA on a system or process that has an operational history, we have information specific to the task based on this history and experience. In the case of a Probabilistic Risk Assessment (PRA) that is based on a new design and has no operational history, providing a "reasonable" assessment of potential crew actions becomes more challenging. To determine what is expected of future operational parameters, the experience from individuals who had relevant experience and were familiar with the system and process previously implemented by NASA was used to provide the "best" available data. Personnel from Flight Operations, Flight Directors, Launch Test Directors, Control Room Console Operators, and Astronauts were all interviewed to provide a comprehensive picture of previous NASA operations. Verification of the assumptions and expectations expressed in the assessments will be needed when the procedures, flight rules, and operational requirements are developed and then finalized.
Human Reliability Assessments: Using the Past (Shuttle) to Predict the Future (Orion)
NASA Technical Reports Server (NTRS)
DeMott, Diana; Bigler, Mark
2016-01-01
NASA (National Aeronautics and Space Administration) Johnson Space Center (JSC) Safety and Mission Assurance (S&MA) uses two human reliability analysis (HRA) methodologies. The first is a simplified method which is based on how much time is available to complete the action, with consideration included for environmental and personal factors that could influence the human's reliability. This method is expected to provide a conservative value or placeholder as a preliminary estimate. This preliminary estimate or screening value is used to determine which placeholder needs a more detailed assessment. The second methodology is used to develop a more detailed human reliability assessment on the performance of critical human actions. This assessment needs to consider more than the time available, this would include factors such as: the importance of the action, the context, environmental factors, potential human stresses, previous experience, training, physical design interfaces, available procedures/checklists and internal human stresses. The more detailed assessment is expected to be more realistic than that based primarily on time available. When performing an HRA on a system or process that has an operational history, we have information specific to the task based on this history and experience. In the case of a Probabilistic Risk Assessment (PRA) that is based on a new design and has no operational history, providing a "reasonable" assessment of potential crew actions becomes more challenging. In order to determine what is expected of future operational parameters, the experience from individuals who had relevant experience and were familiar with the system and process previously implemented by NASA was used to provide the "best" available data. Personnel from Flight Operations, Flight Directors, Launch Test Directors, Control Room Console Operators and Astronauts were all interviewed to provide a comprehensive picture of previous NASA operations. Verification of the assumptions and expectations expressed in the assessments will be needed when the procedures, flight rules and operational requirements are developed and then finalized.
NASA Technical Reports Server (NTRS)
Kelly, Michael J.
2010-01-01
This report documents the activities, findings, and NASA Engineering and Safety Center (NESC) recommendations of a multidiscipline team to independently assess the Constellation Program (CxP) Crew Exploration Vehicle (CEV) Parachute Assembly System (CPAS). This assessment occurred during a period of 15 noncontiguous months between December 2008 and April 2010, prior to the CPAS Project's Preliminary Design Review (PDR) in August 2010.
Decision-theoretic methodology for reliability and risk allocation in nuclear power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, N.Z.; Papazoglou, I.A.; Bari, R.A.
1985-01-01
This paper describes a methodology for allocating reliability and risk to various reactor systems, subsystems, components, operations, and structures in a consistent manner, based on a set of global safety criteria which are not rigid. The problem is formulated as a multiattribute decision analysis paradigm; the multiobjective optimization, which is performed on a PRA model and reliability cost functions, serves as the guiding principle for reliability and risk allocation. The concept of noninferiority is used in the multiobjective optimization problem. Finding the noninferior solution set is the main theme of the current approach. The assessment of the decision maker's preferencesmore » could then be performed more easily on the noninferior solution set. Some results of the methodology applications to a nontrivial risk model are provided and several outstanding issues such as generic allocation and preference assessment are discussed.« less
A new real-time visual assessment method for faulty movement patterns during a jump-landing task.
Rabin, Alon; Levi, Ran; Abramowitz, Shai; Kozol, Zvi
2016-07-01
Determine the interrater reliability of a new real-time assessment of faulty movement patterns during a jump-landing task. Interrater reliability study. Human movement laboratory. 50 healthy females. Assessment included 6 items which were evaluated from a front and a side view. Two Physical Therapy students used a 9-point scale (0-8) to independently rate the quality of movement as good (0-2), moderate (3-5), or poor (6-8). Interrater reliability was expressed by percent agreement and weighted kappa. One examiner rated the quality of movement of 6 subjects as good, 34 subjects as moderate, and 10 subjects as poor. The second examiner rated the quality of movement of 12 subjects as good, 23 subjects as moderate, and 15 subjects as poor. Percent agreement and weighted kappa (95% confidence interval) were 78% and 0.68 (0.51, 0.85), respectively. A new real-time assessment of faulty movement patterns during jump-landing demonstrated adequate interrater reliability. Further study is warranted to validate this method against a motion analysis system, as well as to establish its predictive validity for injury. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
D'silva, Oneil; Kerrison, Roger
2013-09-01
A key feature for the increased utilization of space robotics is to automate Extra-Vehicular manned space activities and thus significantly reduce the potential for catastrophic hazards while simultaneously minimizing the overall costs associated with manned space. The principal scope of the paper is to evaluate the use of industry standard accepted Probability risk/safety assessment (PRA/PSA) methodologies and Hazard Risk frequency Criteria as a hazard control. This paper illustrates the applicability of combining the selected Probability risk assessment methodology and hazard risk frequency criteria, in order to apply the necessary safety controls that allow for the increased use of the Mobile Servicing system (MSS) robotic system on the International Space Station. This document will consider factors such as component failure rate reliability, software reliability, and periods of operation and dormancy, fault tree analyses and their effects on the probability risk assessments. The paper concludes with suggestions for the incorporation of existing industry Risk/Safety plans to create an applicable safety process for future activities/programs
Krause, David A; Boyd, Michael S; Hager, Allison N; Smoyer, Eric C; Thompson, Anthony T; Hollman, John H
2015-02-01
The squat is a fundamental movement of many athletic and daily activities. Methods to clinically assess the squat maneuver range from simple observation to the use of sophisticated equipment. The purpose of this study was to examine the reliability of Coach's Eye (TechSmith Corp), a 2-dimensional (2D) motion analysis mobile device application (app), for assessing maximal sagittal plane hip, knee, and ankle motion during a functional movement screen deep squat, and to compare range of motion values generated by it to those from a Vicon (Vicon Motion Systems Ltd) 3-dimensional (3D) motion analysis system. Twenty-six healthy subjects performed three functional movement screen deep squats recorded simultaneously by both the app (on an iPad [Apple Inc]) and the 3D motion analysis system. Joint angle data were calculated with Vicon Nexus software (Vicon Motion Systems Ltd). The app video was analyzed frame by frame to determine, and freeze on the screen, the deepest position of the squat. With a capacitive stylus reference lines were then drawn on the iPad screen to determine joint angles. Procedures were repeated with approximately 48 hours between sessions. Test-retest intrarater reliability (ICC3,1) for the app at the hip, knee, and ankle was 0.98, 0.98, and 0.79, respectively. Minimum detectable change was hip 6°, knee 6°, and ankle 7°. Hip joint angles measured with the 2D app exceeded measurements obtained with the 3D motion analysis system by approximately 40°. Differences at the knee and ankle were of lower magnitude, with mean differences of 5° and 3°, respectively. Bland-Altman analysis demonstrated a systematic bias in the hip range-of-motion measurement. No such bias was demonstrated at the knee or ankle. The 2D app demonstrated excellent reliability and appeared to be a responsive means to assess for clinical change, with minimum detectable change values ranging from 6° to 7°. These results also suggest that the 2D app may be used as an alternative to a sophisticated 3D motion analysis system for assessing sagittal plane knee and ankle motion; however, it does not appear to be a comparable alternative for assessing hip motion. 3.
Market assessment of photovoltaic power systems for agricultural applications in Nigeria
NASA Technical Reports Server (NTRS)
Staples, D.; Steingass, H.; Nolfi, J.
1981-01-01
The market potential for stand-alone photovoltaic systems in agriculture was studied. Information is presented on technical and economically feasible applications, and assessments of the business, government and financial climate for photovoltaic sales. It is concluded that the market for stand-alone systems will be large because of the availability of captial and the high premium placed on high reliability, low maintenance power systems. Various specific applications are described, mostly related to agriculture.
Market assessment of photovoltaic power systems for agricultural applications in Nigeria
NASA Astrophysics Data System (ADS)
Staples, D.; Steingass, H.; Nolfi, J.
1981-10-01
The market potential for stand-alone photovoltaic systems in agriculture was studied. Information is presented on technical and economically feasible applications, and assessments of the business, government and financial climate for photovoltaic sales. It is concluded that the market for stand-alone systems will be large because of the availability of captial and the high premium placed on high reliability, low maintenance power systems. Various specific applications are described, mostly related to agriculture.
NASA Technical Reports Server (NTRS)
1988-01-01
A user's workshop for CARE 3, a reliability assessment tool designed and developed especially for the evaluation of high reliability fault tolerant digital systems, was held at NASA Langley Research Center on October 6 to 7, 1987. The main purpose of the workshop was to assess the evolutionary status of CARE 3. The activities of the workshop are documented and papers are included by user's of CARE 3 and NASA. Features and limitations of CARE 3 and comparisons to other tools are presented. The conclusions to a workshop questionaire are also discussed.
NASA Technical Reports Server (NTRS)
Connolly, J. C.; Alphonse, G. A.; Carlin, D. B.; Ettenberg, M.
1991-01-01
The operating characteristics (power-current, beam divergence, etc.) and reliability assessment of high-power CSP lasers is discussed. The emission wavelength of these lasers was optimized at 860 to 880 nm. The operational characteristics of a new laser, the inverse channel substrate planar (ICSP) laser, grown by metalorganic chemical vapor deposition (MOCVD), is discussed and the reliability assessment of this laser is reported. The highlights of this study include a reduction in the threshold current value for the laser to 15 mA and a degradation rate of less than 2 kW/hr for the lasers operating at 60 mW of peak output power.
NASA Astrophysics Data System (ADS)
McPhee, J.; William, Y. W.
2005-12-01
This work presents a methodology for pumping test design based on the reliability requirements of a groundwater model. Reliability requirements take into consideration the application of the model results in groundwater management, expressed in this case as a multiobjective management model. The pumping test design is formulated as a mixed-integer nonlinear programming (MINLP) problem and solved using a combination of genetic algorithm (GA) and gradient-based optimization. Bayesian decision theory provides a formal framework for assessing the influence of parameter uncertainty over the reliability of the proposed pumping test. The proposed methodology is useful for selecting a robust design that will outperform all other candidate designs under most potential 'true' states of the system
ERIC Educational Resources Information Center
Heun, Christopher
2006-01-01
With federal funding riding on test scores, student performance is crucial. Information systems are an important ingredient of assessments that are sometimes overlooked. Small rural school districts, such as Orange County, Virginia, often have only a modest IT budget and must find ways to improve the reliability and redundancy of their systems.…
NASA Astrophysics Data System (ADS)
Boron, Sergiusz
2017-06-01
Operational safety of electrical machines and equipment depends, inter alia, on the hazards resulting from their use and on the scope of applied protective measures. The use of insufficient protection against existing hazards leads to reduced operational safety, particularly under fault conditions. On the other hand, excessive (in relation to existing hazards) level of protection may compromise the reliability of power supply. This paper analyses the explosion hazard created by earth faults in longwall power supply systems and evaluates existing protection equipment from the viewpoint of its protective performance, particularly in the context of explosion hazards, and also assesses its effect on the reliability of power supply.
Panzer, Stephanie; Mc Coy, Mark R; Hitzl, Wolfgang; Piombino-Mascali, Dario; Jankauskas, Rimantas; Zink, Albert R; Augat, Peter
2015-01-01
The purpose of this study was to develop a checklist for standardized assessment of soft tissue preservation in human mummies based on whole-body computed tomography examinations, and to add a scoring system to facilitate quantitative comparison of mummies. Computed tomography examinations of 23 mummies from the Capuchin Catacombs of Palermo, Sicily (17 adults, 6 children; 17 anthropogenically and 6 naturally mummified) and 7 mummies from the crypt of the Dominican Church of the Holy Spirit of Vilnius, Lithuania (5 adults, 2 children; all naturally mummified) were used to develop the checklist following previously published guidelines. The scoring system was developed by assigning equal scores for checkpoints with equivalent quality. The checklist was evaluated by intra- and inter-observer reliability. The finalized checklist was applied to compare the groups of anthropogenically and naturally mummified bodies. The finalized checklist contains 97 checkpoints and was divided into two main categories, "A. Soft Tissues of Head and Musculoskeletal System" and "B. Organs and Organ Systems", each including various subcategories. The complete checklist had an intra-observer reliability of 98% and an inter-observer reliability of 93%. Statistical comparison revealed significantly higher values in anthropogenically compared to naturally mummified bodies for the total score and for three subcategories. In conclusion, the developed checklist allows for a standardized assessment and documentation of soft tissue preservation in whole-body computed tomography examinations of human mummies. The scoring system facilitates a quantitative comparison of the soft tissue preservation status between single mummies or mummy collections.
Advanced Launch System Multi-Path Redundant Avionics Architecture Analysis and Characterization
NASA Technical Reports Server (NTRS)
Baker, Robert L.
1993-01-01
The objective of the Multi-Path Redundant Avionics Suite (MPRAS) program is the development of a set of avionic architectural modules which will be applicable to the family of launch vehicles required to support the Advanced Launch System (ALS). To enable ALS cost/performance requirements to be met, the MPRAS must support autonomy, maintenance, and testability capabilities which exceed those present in conventional launch vehicles. The multi-path redundant or fault tolerance characteristics of the MPRAS are necessary to offset a reduction in avionics reliability due to the increased complexity needed to support these new cost reduction and performance capabilities and to meet avionics reliability requirements which will provide cost-effective reductions in overall ALS recurring costs. A complex, real-time distributed computing system is needed to meet the ALS avionics system requirements. General Dynamics, Boeing Aerospace, and C.S. Draper Laboratory have proposed system architectures as candidates for the ALS MPRAS. The purpose of this document is to report the results of independent performance and reliability characterization and assessment analyses of each proposed candidate architecture and qualitative assessments of testability, maintainability, and fault tolerance mechanisms. These independent analyses were conducted as part of the MPRAS Part 2 program and were carried under NASA Langley Research Contract NAS1-17964, Task Assignment 28.
Implications of DSM-5 for the diagnosis of pediatric eating disorders.
Limburg, Karina; Shu, Chloe Y; Watson, Hunna J; Hoiles, Kimberley J; Egan, Sarah J
2018-05-01
The aim of the study was to compare the DSM-IV, DSM-5, and ICD-10 eating disorders (ED) nomenclatures to assess their value in the classification of pediatric eating disorders. We investigated the prevalence of the disorders in accordance with each system's diagnostic criteria, diagnostic concordance between the systems, and interrater reliability. Participants were 1062 children and adolescents assessed at intake to a specialist Eating Disorders Program (91.6% female, mean age 14.5 years, SD = 1.75). Measures were collected from routine intake assessments. DSM-5 categorization led to a lower prevalence of unspecified EDs when compared with DSM-IV. There was almost complete overlap for specified EDs. Kappa values indicated almost excellent agreement between the two coders on all three diagnostic systems, although there was higher interrater reliability for DSM-5 and ICD-10 when compared with DSM-IV. DSM-5 nomenclature is useful in classifying eating disorders in pediatric clinical samples. © 2018 Wiley Periodicals, Inc.
Bader, Michael D. M.; Mooney, Stephen J.; Lee, Yeon Jin; Sheehan, Daniel; Neckerman, Kathryn M.; Rundle, Andrew G.; Teitler, Julien O.
2014-01-01
Public health research has shown that neighborhood conditions are associated with health behaviors and outcomes. Systematic neighborhood audits have helped researchers measure neighborhood conditions that they deem theoretically relevant but not available in existing administrative data. Systematic audits, however, are expensive to conduct and rarely comparable across geographic regions. We describe the development of an online application, the Computer Assisted Neighborhood Visual Assessment System (CANVAS), that uses Google Street View to conduct virtual audits of neighborhood environments. We use this system to assess the inter-rater reliability of 187 items related to walkability and physical disorder on a national sample of 150 street segments in the United States. We find that many items are reliably measured across auditors using CANVAS and that agreement between auditors appears to be uncorrelated with neighborhood demographic characteristics. Based on our results we conclude that Google Street View and CANVAS offer opportunities to develop greater comparability across neighborhood audit studies. PMID:25545769
NASA Astrophysics Data System (ADS)
Ndiritu, John; Ilemobade, Adesola; Kagoda, Paulo
2018-06-01
As water demand increases rainwater harvesting (RWH) systems are increasingly being installed for water supply but comprehensive hydrologic design guidelines for RWH do not exist in many parts of the world. The objective of this study was to develop guidelines for the hydrologic design and assessment of rainwater harvesting (RWH) systems in the City of Johannesburg, South Africa. The data for developing the guidelines were mainly obtained from multiple daily simulations of potential RWH systems in the city. The simulations used daily rainfall from 8 stations and demands based on the probable non-potable uses of RWH systems - toilet flushing, air conditioning and irrigation. The guidelines were confined to systems that would typically fill up in the wet season and empty towards the end of the dry season of the same year. Therefore, supply-to-demand ratios ranging from 0.1 to 0.9 were applied. Two generalized design charts of dimensionless relationships were developed. One relates the yield ratio with supply-to-demand ratio and reliability while the other relates the yield ratio with the storage-to-demand ratio and reliability. Reliability was defined as the probability of exceedance of annual yield in order to incorporate the large inter-annual variability of rainfall experienced in the region. The analyses and design of an example RWH system is used to illustrate the application of the design charts.
Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos
2018-04-01
This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.
Fiori, Simona; Cioni, Giovanni; Klingels, Katrjin; Ortibus, Els; Van Gestel, Leen; Rose, Stephen; Boyd, Roslyn N; Feys, Hilde; Guzzetta, Andrea
2014-09-01
To describe the development of a novel rating scale for classification of brain structural magnetic resonance imaging (MRI) in children with cerebral palsy (CP) and to assess its interrater and intrarater reliability. The scale consists of three sections. Section 1 contains descriptive information about the patient and MRI. Section 2 contains the graphical template of brain hemispheres onto which the lesion is transposed. Section 3 contains the scoring system for the quantitative analysis of the lesion characteristics, grouped into different global scores and subscores that assess separately side, regions, and depth. A larger interrater and intrarater reliability study was performed in 34 children with CP (22 males, 12 females; mean age at scan of 9 y 5 mo [SD 3 y 3 mo], range 4 y-16 y 11 mo; Gross Motor Function Classification System level I, [n=22], II [n=10], and level III [n=2]). Very high interrater and intrarater reliability of the total score was found with indices above 0.87. Reliability coefficients of the lobar and hemispheric subscores ranged between 0.53 and 0.95. Global scores for hemispheres, basal ganglia, brain stem, and corpus callosum showed reliability coefficients above 0.65. This study presents the first visual, semi-quantitative scale for classification of brain structural MRI in children with CP. The high degree of reliability of the scale supports its potential application for investigating the relationship between brain structure and function and examining treatment response according to brain lesion severity in children with CP. © 2014 Mac Keith Press.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Touati, Said; Chennai, Salim; Souli, Aissa
The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how wellmore » a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)« less
The purpose of the field demonstration program is to gather technically reliable cost and performance information on selected condition assessment technologies under defined field conditions. The selected technologies include zoom camera, focused electrode leak location (FELL), ...
DOT National Transportation Integrated Search
1981-03-01
This project was conducted as part of UMTA's Rail Transit Fare Collection Program developed by the Transportation Systems Center of the U.S. Department of Transportation. The report presents a generalized survey methodology for conducting assessments...
Patient-centered technological assessment and monitoring of depression for low-income patients.
Wu, Shinyi; Vidyanti, Irene; Liu, Pai; Hawkins, Caitlin; Ramirez, Magaly; Guterman, Jeffrey; Gross-Schulman, Sandra; Sklaroff, Laura Myerchin; Ell, Kathleen
2014-01-01
Depression is a significant challenge for ambulatory care because it worsens health status and outcomes, increases health care utilizations and costs, and elevates suicide risk. An automatic telephonic assessment (ATA) system that links with tasks and alerts to providers may improve quality of depression care and increase provider productivity. We used ATA system in a trial to assess and monitor depressive symptoms of 444 safety-net primary care patients with diabetes. We assessed system properties, evaluated preliminary clinical outcomes, and estimated cost savings. The ATA system is feasible, reliable, valid, safe, and likely cost-effective for depression screening and monitoring for low-income primary care population.
Mahmoud, Asmaa; Abundo, Paolo; Basile, Luisanna; Albensi, Caterina; Marasco, Morena; Bellizzi, Letizia; Galasso, Franco; Foti, Calogero
2017-01-01
Summary Background In spite the instinct social&financial impact of Leg Length Discrepancy (LLD), controversial and conflicting results still exist regarding a reliable assessment/correction method. For proper management it’s essential to discriminate between anatomical&functional Leg Length Discrepancy (FLLD). With the newly invented NPoS (New Postural Solution), under the umbrella of the collaboration of PRM Department, Tor Vergata University with Baro Postural Instruments srl, positive results were observed in both measuring& compensating the hemi-pelvic antero-medial rotation in FLLD through personalized bilateral heel raise using two NPoS components: Foot Image System (FIS) and Postural Optimizer System (POS). This led our research interest to test the validity of NPoS as a preliminary step before evaluating its implementations in postural disorders. Methods After clinical evaluation, 4 subjects with FLLD have been assessed by NPoS. Over a period of 2 months, every subject was evaluated 12 times by two different operators, 48 measurements in total, results have been verified in correlation to BTS GaitLab results. Results Intra-Operator&inter-operator variability analysis showed statistically insignificant differences, while inter-method variability between NPoS and BTS parameters expressed a linear correlation. Conclusion Results suggest a significant validity of NPoS in assessment&correction of FLLD, with high degree of reproducibility with minimal operator dependency. This can be considered a base for promising clinical implications of NPoS as a reliable cost effective postural assessment/corrective tool. Level of evidence V. PMID:29264341
ERIC Educational Resources Information Center
Hartwig, Laurie; Heathfield, Lora Tuesday; Jenson, William R.
2004-01-01
The purpose of this study was to develop standardization data for the Functional Assessment Intervention Program (FAIP; University of Utah, Utah State University, & Utah State Office of Education, 1999), a computerized, functional behavioral assessment expert system. Reliability, validity, and utility analyses were conducted with students serving…
Assessing I-Grid(TM) web-based monitoring for power quality and reliability benchmarking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Divan, Deepak; Brumsickle, William; Eto, Joseph
2003-04-30
This paper presents preliminary findings from DOEs pilot program. The results show how a web-based monitoring system can form the basis for aggregation of data and correlation and benchmarking across broad geographical lines. A longer report describes additional findings from the pilot, including impacts of power quality and reliability on customers operations [Divan, Brumsickle, Eto 2003].
The implementation and use of Ada on distributed systems with high reliability requirements
NASA Technical Reports Server (NTRS)
Knight, J. C.
1986-01-01
The use and implementation of Ada in distributed environments in which reliability is the primary concern were investigted. A distributed system, programmed entirely in Ada, was studied to assess the use of individual tasks without concern for the processor used. Continued development and testing of the fault tolerant Ada testbed; development of suggested changes to Ada to cope with the failures of interest; design of approaches to fault tolerant software in real time systems, and the integration of these ideas into Ada; and the preparation of various papers and presentations were discussed.
NASA Astrophysics Data System (ADS)
Miara, A.; Macknick, J.; Vorosmarty, C. J.; Corsi, F.; Fekete, B. M.; Newmark, R. L.; Tidwell, V. C.; Cohen, S. M.
2016-12-01
Thermoelectric plants supply 85% of electricity generation in the United States. Under a warming climate, the performance of these power plants may be reduced, as thermoelectric generation is dependent upon cool ambient temperatures and sufficient water supplies at adequate temperatures. In this study, we assess the vulnerability and reliability of 1,100 operational power plants (2015) across the contiguous United States under a comprehensive set of climate scenarios (five Global Circulation Models each with four Representative Concentration Pathways). We model individual power plant capacities using the Thermoelectric Power and Thermal Pollution model (TP2M) coupled with the Water Balance Model (WBM) at a daily temporal resolution and 5x5 km spatial resolution. Together, these models calculate power plant capacity losses that account for geophysical constraints and river network dynamics. Potential losses at the single-plant level are put into a regional energy security context by assessing the collective system-level reliability at the North-American Electricity Reliability Corporation (NERC) regions. Results show that the thermoelectric sector at the national level has low vulnerability under the contemporary climate and that system-level reliability in terms of available thermoelectric resources relative to thermoelectric demand is sufficient. Under future climates scenarios, changes in water availability and warm ambient temperatures lead to constraints on operational capacity and increased vulnerability at individual power plant sites across all regions in the United States. However, there is a strong disparity in regional vulnerability trends and magnitudes that arise from each region's climate, hydrology and technology mix. Despite increases in vulnerabilities at the individual power plant level, regional energy systems may still be reliable (with no system failures) due to sufficient back-up reserve capacities.
Sorsdahl, Anne Brit; Moe-Nilssen, Rolf; Strand, Liv Inger
2008-02-01
The aim of this study was to examine observer reliability of the Gross Motor Performance Measure (GMPM) and the Quality of Upper Extremity Skills Test (QUEST) based on video clips. The tests were administered to 26 children with cerebral palsy (CP; 14 males, 12 females; range 2-13y, mean 7y 6mo), 24 with spastic CP, and two with dyskinesia. Respectively, five, six, five, four, and six children were classified in Gross Motor Function Classification System Levels I to V; and four, nine, five, five, and three children were classified in Manual Ability Classification System levels I to V. The children's performances were recorded and edited. Two experienced paediatric physical therapists assessed the children from watching the video clips. Intraobserver and interobserver reliability values of the total scores were mostly high, intraclass correlation coefficient (ICC)(1,1) varying from 0.69 to 0.97 with only one coefficient below 0.89. The ICCs of subscores varied from 0.36 to 0.95, finding'Alignment'and'Weight shift'in GMPM and'Protective extension'in QUEST highly reliable. The subscores'Dissociated movements'in GMPM and QUEST, and'Grasp'in QUEST were the least reliable, and recommendations are made to increase reliability of these subscores. Video scoring was time consuming, but was found to offer many advantages; the possibility to review performance, to use special trained observers for scoring and less demanding assessment for the children.
Reliability and validity of an accele-rometric system for assessing vertical jumping performance.
Choukou, M-A; Laffaye, G; Taiar, R
2014-03-01
The validity of an accelerometric system (Myotest©) for assessing vertical jump height, vertical force and power, leg stiffness and reactivity index was examined. 20 healthy males performed 3×"5 hops in place", 3×"1 squat jump" and 3× "1 countermovement jump" during 2 test-retest sessions. The variables were simultaneously assessed using an accelerometer and a force platform at a frequency of 0.5 and 1 kHz, respectively. Both reliability and validity of the accelerometric system were studied. No significant differences between test and retest data were found (p < 0.05), showing a high level of reliability. Besides, moderate to high intraclass correlation coefficients (ICCs) (from 0.74 to 0.96) were obtained for all variables whereas weak to moderate ICCs (from 0.29 to 0.79) were obtained for force and power during the countermovement jump. With regards to validity, the difference between the two devices was not significant for 5 hops in place height (1.8 cm), force during squat (-1.4 N · kg(-1)) and countermovement (0.1 N · kg(-1)) jumps, leg stiffness (7.8 kN · m(-1)) and reactivity index (0.4). So, the measurements of these variables with this accelerometer are valid, which is not the case for the other variables. The main causes of non-validity for velocity, power and contact time assessment are temporal biases of the takeoff and touchdown moments detection.
RELIABILITY AND VALIDITY OF AN ACCELEROMETRIC SYSTEM FOR ASSESSING VERTICAL JUMPING PERFORMANCE
Laffaye, G.; Taiar, R.
2014-01-01
The validity of an accelerometric system (Myotest©) for assessing vertical jump height, vertical force and power, leg stiffness and reactivity index was examined. 20 healthy males performed 3ד5 hops in place”, 3ד1 squat jump” and 3× “1 countermovement jump” during 2 test-retest sessions. The variables were simultaneously assessed using an accelerometer and a force platform at a frequency of 0.5 and 1 kHz, respectively. Both reliability and validity of the accelerometric system were studied. No significant differences between test and retest data were found (p < 0.05), showing a high level of reliability. Besides, moderate to high intraclass correlation coefficients (ICCs) (from 0.74 to 0.96) were obtained for all variables whereas weak to moderate ICCs (from 0.29 to 0.79) were obtained for force and power during the countermovement jump. With regards to validity, the difference between the two devices was not significant for 5 hops in place height (1.8 cm), force during squat (-1.4 N · kg−1) and countermovement (0.1 N · kg−1) jumps, leg stiffness (7.8 kN · m−1) and reactivity index (0.4). So, the measurements of these variables with this accelerometer are valid, which is not the case for the other variables. The main causes of non-validity for velocity, power and contact time assessment are temporal biases of the takeoff and touchdown moments detection. PMID:24917690
NASA Technical Reports Server (NTRS)
Kleinhammer, Roger K.; Graber, Robert R.; DeMott, D. L.
2016-01-01
Reliability practitioners advocate getting reliability involved early in a product development process. However, when assigned to estimate or assess the (potential) reliability of a product or system early in the design and development phase, they are faced with lack of reasonable models or methods for useful reliability estimation. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, analysts attempt to develop the "best" or composite analog data to support the assessments. Industries, consortia and vendors across many areas have spent decades collecting, analyzing and tabulating fielded item and component reliability performance in terms of observed failures and operational use. This data resource provides a huge compendium of information for potential use, but can also be compartmented by industry, difficult to find out about, access, or manipulate. One method used incorporates processes for reviewing these existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component. It can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. It also establishes a baseline prior that may updated based on test data or observed operational constraints and failures, i.e., using Bayesian techniques. This tutorial presents a descriptive compilation of historical data sources across numerous industries and disciplines, along with examples of contents and data characteristics. It then presents methods for combining failure information from different sources and mathematical use of this data in early reliability estimation and analyses.
A thermal vacuum-UV solar simulator test system for assessing microbiological viability
NASA Technical Reports Server (NTRS)
Ross, D. S.; Wardle, M. D.; Taylor, D. M.
1975-01-01
Microorganisms were exposed to a simulated space environment in order to assess the photobiological effect of broad spectrum, nonionizing solar electromagnetic radiation in terms of viability. A thermal vacuum chamber capable of maintaining a vacuum of 0.000133n/sq m and an ultraviolet rich solar simulator were the main ingredients of the test system. Results to date indicate the system to be capable of providing reliable microbiological data.
Stoller, Oliver; de Bruin, Eling D; Schindelholz, Matthias; Schuster-Amft, Corina; de Bie, Rob A; Hunt, Kenneth J
2014-10-11
Exercise capacity is seriously reduced after stroke. While cardiopulmonary assessment and intervention strategies have been validated for the mildly and moderately impaired populations post-stroke, there is a lack of effective concepts for stroke survivors suffering from severe motor limitations. This study investigated the test-retest reliability and repeatability of cardiopulmonary exercise testing (CPET) using feedback-controlled robotics-assisted treadmill exercise (FC-RATE) in severely motor impaired individuals early after stroke. 20 subjects (age 44-84 years, <6 month post-stroke) with severe motor limitations (Functional Ambulatory Classification 0-2) were selected for consecutive constant load testing (CLT) and incremental exercise testing (IET) within a powered exoskeleton, synchronised with a treadmill and a body weight support system. A manual human-in-the-loop feedback system was used to guide individual work rate levels. Outcome variables focussed on standard cardiopulmonary performance parameters. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean difference, limits of agreement, and coefficient of variation (CoV) were estimated to assess repeatability. Peak performance parameters during IET yielded good to excellent relative reliability: absolute peak oxygen uptake (ICC =0.82), relative peak oxygen uptake (ICC =0.72), peak work rate (ICC =0.91), peak heart rate (ICC =0.80), absolute gas exchange threshold (ICC =0.91), relative gas exchange threshold (ICC =0.88), oxygen cost of work (ICC =0.87), oxygen pulse at peak oxygen uptake (ICC =0.92), ventilation rate versus carbon dioxide output slope (ICC =0.78). For these variables, SEM was 4-13%, MDC 12-36%, and CoV 0.10-0.36. CLT revealed high mean differences and insufficient test-retest reliability for all variables studied. This study presents first evidence on reliability and repeatability for CPET in severely motor impaired individuals early after stroke using a feedback-controlled robotics-assisted treadmill. The results demonstrate good to excellent test-retest reliability and appropriate repeatability for the most important peak cardiopulmonary performance parameters. These findings have important implications for the design and implementation of cardiovascular exercise interventions in severely impaired populations. Future research needs to develop advanced control strategies to enable the true limit of functional exercise capacity to be reached and to further assess test-retest reliability and repeatability in larger samples.
Tabard-Fougère, Anne; Bonnefoy-Mazure, Alice; Hanquinet, Sylviane; Lascombes, Pierre; Armand, Stéphane; Dayer, Romain
2017-01-15
Test-retest study. This study aimed to evaluate the validity and reliability of rasterstereography in patients with adolescent idiopathic scoliosis (AIS) with a major curve Cobb angle (CA) between 10° and 40° for frontal, sagittal, and transverse parameters. Previous studies evaluating the validity and reliability of rasterstereography concluded that this technique had good accuracy compared with radiographs and a high intra- and interday reliability in healthy volunteers. To the best of our knowledge, the validity and reliability have not been assessed in AIS patients. Thirty-five adolescents with AIS (male = 13) aged 13.1 ± 2.0 years were included. To evaluate the validity of the scoliosis angle (SA) provided by rasterstereography, a comparison (t test, Pearson correlation) was performed with the CA obtained using 2D EOS® radiography (XR). Three rasterstereographic repeated measurements were independently performed by two operators on the same day (interrater reliability) and again by the first operator 1 week later (intrarater reliability). The variables of interest were the SA, lumbar lordosis, and thoracic kyphosis angle, trunk length, pelvic obliquity, and maximum, root mean square and amplitude of vertebral rotations. The data analyses used intraclass correlation coefficients (ICCs). The CA and SA were strongly correlated (R = 0.70) and were nonsignificantly different (P = 0.60). The intrarater reliability (same day: ICC [1, 1], n = 35; 1 week later: ICC [1, 3], n = 28) and interrater reliability (ICC [3, 3], n = 16) were globally excellent (ICC > 0.75) except for the assessment of pelvic obliquity. This study showed that the rasterstereographic system allows for the evaluation of AIS patients with a good validity compared with XR with an overall excellent intra- and interrater reliability. Based on these results, this automatic, fast, and noninvasive system can be used for monitoring the evolution of AIS in growing patients instead of repetitive radiographs, thereby reducing radiation exposure and decreasing costs. 4.
Reliability assessment and improvement for a fast corrector power supply in TPS
NASA Astrophysics Data System (ADS)
Liu, Kuo-Bin; Liu, Chen-Yao; Wang, Bao-Sheng; Wong, Yong Seng
2018-07-01
Fast Orbit Feedback System (FOFB) can be installed in a synchrotron light source to eliminate undesired disturbances and to improve the stability of beam orbit. The design and implementation of an accurate and reliable Fast Corrector Power Supply (FCPS) is essential to realize the effectiveness and availability of the FOFB. A reliability assessment for the FCPSs in the FOFB of Taiwan Photon Source (TPS) considering MOSFETs' temperatures is represented in this paper. The FCPS is composed of a full-bridge topology and a low-pass filter. A Hybrid Pulse Width Modulation (HPWM) requiring two MOSFETs in the full-bridge circuit to be operated at high frequency and the other two be operated at the output frequency is adopted to control the implemented FCPS. Due the characteristic of HPWM, the conduction loss and switching loss of each MOSFET in the FCPS is not same. Two of the MOSFETs in the full-bridge circuit will suffer higher temperatures and therefore the circuit reliability of FCPS is reduced. A Modified PWM Scheme (MPWMS) designed to average MOSFETs' temperatures and to improve circuit reliability is proposed in this paper. Experimental results measure the MOSFETs' temperatures of FCPS controlled by the HPWM and the proposed MPWMS. The reliability indices under different PWM controls are then assessed. From the experimental results, it can be observed that the reliability of FCPS using the proposed MPWMS can be improved because the MOSFETs' temperatures are closer. Since the reliability of FCPS can be enhanced, the availability of FOFB can also be improved.
Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel
2016-01-01
Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723
Rosa-Rizzotto, M; Visonà Dalla Pozza, L; Corlatti, A; Luparia, A; Marchi, A; Molteni, F; Facchin, P; Pagliano, E; Fedrizzi, E
2014-10-01
In hemiplegic children, the recognition of the activity limitation pattern and the possibility of grading its severity are relevant for clinicians while planning interventions, monitoring results, predicting outcomes. Aim of the study is to examine the reliability and validity of Besta Scale, an instrument used to measure in hemiplegic children from 18 months to 12 years of age both grasp on request (capacity) and spontaneous use of upper limb (performance) in bimanual play activities and in ADL. Psychometric analysis of reliability and of validity of the Besta scale was performed. Outpatient study sample Reliability study: A sample of 39 patients was enrolled. The administration of Besta scale was video-recorded in a standardized manner. All videos were scored by 20 independent raters on subsequent viewing. 3 raters randomly selected from the 20-raters group rescored the same video two years later for intra-rater reliability. Intra and inter-rater reliability were calculated using Intraclass Correlation Coefficient (ICC) and Kendall's coefficient (K), respectively. Internal consistency reliability was assessed using Alpha's Chronbach coefficient. Validity study: a sample of 105 children was assessed 5 times (at t0 and 2, 3, 6 and 12 months later) by 20 independent raters. Each patient underwent at the same time to QUEST and Besta scale administration and assessment. Criterion validity was calculated using rho-Pearson coefficient. Reliability study: The inter-rater reliability calculated with Kendall's coefficient resulted moderate K=0.47. The intra-rater (or test-retest) reliability for 3 raters was excellent (ICC=0.927). The Cronbach's alpha for internal consistency was 0.972. Validity study: Besta scale showed a good criterion validity compared to QUEST increasing by age and severity of impairment. Rho Pearson's correlation coefficient r was 0.81 (P<0.0001). Limitations. Besta scales in infants finds hard to distinguish between mild to moderately impaired hand function. Besta scale scoring system is a valid and reliable tool, utilizable in a clinical setting to monitor evolution of unimanual and bimanual manipulation and to distinguish hand's capacity from performance.
ASSOCIATIONS BETWEEN THREE CLINICAL ASSESSMENT TOOLS FOR POSTURAL STABILITY
Saxion, Casie E.; Cameron, Kenneth L.; Gerber, J. Parry
2010-01-01
Study Design: Clinical Measurement, Correlation, Reliability Objectives: To assess the relationship between the Single Leg Balance (SLB), modified Balance Error Scoring System (mBESS), and modified Star Excursion Balance (mSEBT) tests and secondarily to assess inter-rater and test-retest reliability of these tests. Background: Ankle sprains often result in chronic instability and dysfunction. Several clinical tests assess postural deficits as a potential cause of this dysfunction; however, limited information exists pertaining to the relationship that these tests have with one another. Methods: Two independent examiners measured the performance of 34 healthy participants completing the SLB Test, mBESS test, and mSEBT at two different time periods. The relationship between tests was assessed using the Pearson Correlation and Fisher's Exact Tests. Inter-rater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Kappa statistics. Results: A significant correlation (r = -0.35) was observed between the mSEBT and the mBESS. Fisher's Exact Test showed a significant association between the SLB Test and mBESS (P = .048), but no association between the SLB and mSEBT (P = 1.000). Inter-rater reliability was excellent for the mSEBT and fair for the mBESS (ICCs of .91 and .61 respectively). Excellent agreement was observed between raters for the SLB test (k = 1.00). Test-retest reliability was excellent for the mSEBT (ICC = 0.98) and fair for the mBESS (ICC = 0.74). There was poor test-retest agreement for the SLB test (k = .211). Conclusion: There was a significant relationship observed between the SLB Test, mBESS test, and mSEBT: however; strength of association measures showed limited overlap between these tests. This suggests that these tests are interrelated but may not assess equal components of postural stability. PMID:21589668
Interrater reliability of the mind map assessment rubric in a cohort of medical students.
D'Antoni, Anthony V; Zipp, Genevieve Pinto; Olson, Valerie G
2009-04-28
Learning strategies are thinking tools that students can use to actively acquire information. Examples of learning strategies include mnemonics, charts, and maps. One strategy that may help students master the tsunami of information presented in medical school is the mind map learning strategy. Currently, there is no valid and reliable rubric to grade mind maps and this may contribute to their underutilization in medicine. Because concept maps and mind maps engage learners similarly at a metacognitive level, a valid and reliable concept map assessment scoring system was adapted to form the mind map assessment rubric (MMAR). The MMAR can assess mind map depth based upon concept-links, cross-links, hierarchies, examples, pictures, and colors. The purpose of this study was to examine interrater reliability of the MMAR. This exploratory study was conducted at a US medical school as part of a larger investigation on learning strategies. Sixty-six (N = 66) first-year medical students were given a 394-word text passage followed by a 30-minute presentation on mind mapping. After the presentation, subjects were again given the text passage and instructed to create mind maps based upon the passage. The mind maps were collected and independently scored using the MMAR by 3 examiners. Interrater reliability was measured using the intraclass correlation coefficient (ICC) statistic. Statistics were calculated using SPSS version 12.0 (Chicago, IL). Analysis of the mind maps revealed the following: concept-links ICC = .05 (95% CI, -.42 to .38), cross-links ICC = .58 (95% CI, .37 to .73), hierarchies ICC = .23 (95% CI, -.15 to .50), examples ICC = .53 (95% CI, .29 to .69), pictures ICC = .86 (95% CI, .79 to .91), colors ICC = .73 (95% CI, .59 to .82), and total score ICC = .86 (95% CI, .79 to .91). The high ICC value for total mind map score indicates strong MMAR interrater reliability. Pictures and colors demonstrated moderate to strong interrater reliability. We conclude that the MMAR may be a valid and reliable tool to assess mind maps in medicine. However, further research on the validity and reliability of the MMAR is necessary.
Interrater reliability of the mind map assessment rubric in a cohort of medical students
D'Antoni, Anthony V; Zipp, Genevieve Pinto; Olson, Valerie G
2009-01-01
Background Learning strategies are thinking tools that students can use to actively acquire information. Examples of learning strategies include mnemonics, charts, and maps. One strategy that may help students master the tsunami of information presented in medical school is the mind map learning strategy. Currently, there is no valid and reliable rubric to grade mind maps and this may contribute to their underutilization in medicine. Because concept maps and mind maps engage learners similarly at a metacognitive level, a valid and reliable concept map assessment scoring system was adapted to form the mind map assessment rubric (MMAR). The MMAR can assess mind map depth based upon concept-links, cross-links, hierarchies, examples, pictures, and colors. The purpose of this study was to examine interrater reliability of the MMAR. Methods This exploratory study was conducted at a US medical school as part of a larger investigation on learning strategies. Sixty-six (N = 66) first-year medical students were given a 394-word text passage followed by a 30-minute presentation on mind mapping. After the presentation, subjects were again given the text passage and instructed to create mind maps based upon the passage. The mind maps were collected and independently scored using the MMAR by 3 examiners. Interrater reliability was measured using the intraclass correlation coefficient (ICC) statistic. Statistics were calculated using SPSS version 12.0 (Chicago, IL). Results Analysis of the mind maps revealed the following: concept-links ICC = .05 (95% CI, -.42 to .38), cross-links ICC = .58 (95% CI, .37 to .73), hierarchies ICC = .23 (95% CI, -.15 to .50), examples ICC = .53 (95% CI, .29 to .69), pictures ICC = .86 (95% CI, .79 to .91), colors ICC = .73 (95% CI, .59 to .82), and total score ICC = .86 (95% CI, .79 to .91). Conclusion The high ICC value for total mind map score indicates strong MMAR interrater reliability. Pictures and colors demonstrated moderate to strong interrater reliability. We conclude that the MMAR may be a valid and reliable tool to assess mind maps in medicine. However, further research on the validity and reliability of the MMAR is necessary. PMID:19400964
Performance assessment of the Gash Delta Spate Irrigation System, Sudan
NASA Astrophysics Data System (ADS)
Ghebreamlak, Araya Z.; Tanakamaru, Haruya; Tada, Akio; Adam, Bashir M. Ahmed; Elamin, Khalid A. E.
2018-02-01
The Gash Delta Spate Irrigation System (GDSIS), located in eastern Sudan with a net command area of 100 000 ha (an area currently equipped with irrigation structures), was established in 1924. The land is irrigated every 3 years (3-year rotation) or every 2 years (2-year rotation) so that about 33 000 or 50 000 ha respectively can be cultivated annually. This study deals with assessing the performance of the 3- and 2-year rotation systems using the Monte Carlo simulation. Reliability, which is a measure of how frequently the irrigation water supply satisfies the demand, and vulnerability, which is a measure of the magnitude of failure, were selected as the performance criteria. Combinations of five levels of intake ratio and five levels of irrigation efficiency for the irrigation water supply of each rotation system were analysed. Historical annual flow data of the Gash River for 107 years were fit to several frequency distributions. The Weibull distribution was the best on the basis of the Akaike information criteria and was used for simulating the ensembles of annual river flow. The reliabilities and vulnerabilities of both rotation systems were evaluated at typical values of intake ratio and irrigation efficiency. The results show that (i) the 3-year rotation is more reliable in water supply than the 2-year rotation, (ii) the vulnerability of the 3-year rotation is lower than that of the 2-year rotation and (iii) therefore the 3-year rotation is preferable in the GDSIS. The sensitivities of reliability and vulnerability to changes in intake ratio and irrigation efficiency were also examined.
Rossini, Gabriele; Parrini, Simone; Castroflorio, Tommaso; Deregibus, Andrea; Debernardi, Cesare L
2016-02-01
Our objective was to assess the accuracy, validity, and reliability of measurements obtained from virtual dental study models compared with those obtained from plaster models. PubMed, PubMed Central, National Library of Medicine Medline, Embase, Cochrane Central Register of Controlled Clinical trials, Web of Knowledge, Scopus, Google Scholar, and LILACs were searched from January 2000 to November 2014. A grading system described by the Swedish Council on Technology Assessment in Health Care and the Cochrane tool for risk of bias assessment were used to rate the methodologic quality of the articles. Thirty-five relevant articles were selected. The methodologic quality was high. No significant differences were observed for most of the studies in all the measured parameters, with the exception of the American Board of Orthodontics Objective Grading System. Digital models are as reliable as traditional plaster models, with high accuracy, reliability, and reproducibility. Landmark identification, rather than the measuring device or the software, appears to be the greatest limitation. Furthermore, with their advantages in terms of cost, time, and space required, digital models could be considered the new gold standard in current practice. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Tailoring a Human Reliability Analysis to Your Industry Needs
NASA Technical Reports Server (NTRS)
DeMott, D. L.
2016-01-01
Companies at risk of accidents caused by human error that result in catastrophic consequences include: airline industry mishaps, medical malpractice, medication mistakes, aerospace failures, major oil spills, transportation mishaps, power production failures and manufacturing facility incidents. Human Reliability Assessment (HRA) is used to analyze the inherent risk of human behavior or actions introducing errors into the operation of a system or process. These assessments can be used to identify where errors are most likely to arise and the potential risks involved if they do occur. Using the basic concepts of HRA, an evolving group of methodologies are used to meet various industry needs. Determining which methodology or combination of techniques will provide a quality human reliability assessment is a key element to developing effective strategies for understanding and dealing with risks caused by human errors. There are a number of concerns and difficulties in "tailoring" a Human Reliability Assessment (HRA) for different industries. Although a variety of HRA methodologies are available to analyze human error events, determining the most appropriate tools to provide the most useful results can depend on industry specific cultures and requirements. Methodology selection may be based on a variety of factors that include: 1) how people act and react in different industries, 2) expectations based on industry standards, 3) factors that influence how the human errors could occur such as tasks, tools, environment, workplace, support, training and procedure, 4) type and availability of data, 5) how the industry views risk & reliability, and 6) types of emergencies, contingencies and routine tasks. Other considerations for methodology selection should be based on what information is needed from the assessment. If the principal concern is determination of the primary risk factors contributing to the potential human error, a more detailed analysis method may be employed versus a requirement to provide a numerical value as part of a probabilistic risk assessment. Industries involved with humans operating large equipment or transport systems (ex. railroads or airlines) would have more need to address the man machine interface than medical workers administering medications. Human error occurs in every industry; in most cases the consequences are relatively benign and occasionally beneficial. In cases where the results can have disastrous consequences, the use of Human Reliability techniques to identify and classify the risk of human errors allows a company more opportunities to mitigate or eliminate these types of risks and prevent costly tragedies.
Hughes, Michael; Tracey, Andrew; Bhushan, Monica; Chakravarty, Kuntal; Denton, Christopher P; Dubey, Shirish; Guiducci, Serena; Muir, Lindsay; Ong, Voon; Parker, Louise; Pauling, John D; Prabu, Athiveeraramapandian; Rogers, Christine; Roberts, Christopher; Herrick, Ariane L
2018-06-01
The reliability of clinician grading of systemic sclerosis-related digital ulcers has been reported to be poor to moderate at best, which has important implications for clinical trial design. The aim of this study was to examine the reliability of new proposed UK Scleroderma Study Group digital ulcer definitions among UK clinicians with an interest in systemic sclerosis. Raters graded (through a custom-built interface) 90 images (80 unique and 10 repeat) of a range of digital lesions collected from patients with systemic sclerosis. Lesions were graded on an ordinal scale of severity: 'no ulcer', 'healed ulcer' or 'digital ulcer'. A total of 23 clinicians - 18 rheumatologists, 3 dermatologists, 1 hand surgeon and 1 specialist rheumatology nurse - completed the study. A total of 2070 (1840 unique + 230 repeat) image gradings were obtained. For intra-rater reliability, across all images, the overall weighted kappa coefficient was high (0.71) and was moderate (0.55) when averaged across individual raters. Overall inter-rater reliability was poor (0.15). Although our proposed digital ulcer definitions had high intra-rater reliability, the overall inter-rater reliability was poor. Our study highlights the challenges of digital ulcer assessment by clinicians with an interest in systemic sclerosis and provides a number of useful insights for future clinical trial design. Further research is warranted to improve the reliability of digital ulcer definition/rating as an outcome measure in clinical trials, including examining the role for objective measurement techniques, and the development of digital ulcer patient-reported outcome measures.
A Bayesian approach to reliability and confidence
NASA Technical Reports Server (NTRS)
Barnes, Ron
1989-01-01
The historical evolution of NASA's interest in quantitative measures of reliability assessment is outlined. The introduction of some quantitative methodologies into the Vehicle Reliability Branch of the Safety, Reliability and Quality Assurance (SR and QA) Division at Johnson Space Center (JSC) was noted along with the development of the Extended Orbiter Duration--Weakest Link study which will utilize quantitative tools for a Bayesian statistical analysis. Extending the earlier work of NASA sponsor, Richard Heydorn, researchers were able to produce a consistent Bayesian estimate for the reliability of a component and hence by a simple extension for a system of components in some cases where the rate of failure is not constant but varies over time. Mechanical systems in general have this property since the reliability usually decreases markedly as the parts degrade over time. While they have been able to reduce the Bayesian estimator to a simple closed form for a large class of such systems, the form for the most general case needs to be attacked by the computer. Once a table is generated for this form, researchers will have a numerical form for the general solution. With this, the corresponding probability statements about the reliability of a system can be made in the most general setting. Note that the utilization of uniform Bayesian priors represents a worst case scenario in the sense that as researchers incorporate more expert opinion into the model, they will be able to improve the strength of the probability calculations.
NASA Technical Reports Server (NTRS)
Kelly, Michael J.
2010-01-01
This document contains the Appendices to the report documenting the activities, findings, and NASA Engineering and Safety Center (NESC) recommendations of a multidiscipline team to independently assess the Constellation Program (CxP) Crew Exploration Vehicle (CEV) Parachute Assembly System (CPAS). The assessment occurred during a period of 15 noncontiguous months between December 2008 and April 2010, prior to the CPAS Project's Preliminary Design Review (PDR) in August 2010.
NASA Technical Reports Server (NTRS)
1982-01-01
The integrated application of active controls (IAAC) technology to an advanced subsonic transport is reported. Supplementary technical data on the following topics are included: (1) 1990's avionics technology assessment; (2) function criticality assessment; (3) flight deck system for total control and functional features list; (4) criticality and reliability assessment of units; (5) crew procedural function task analysis; and (6) recommendations for simulation mechanization.
NASA Astrophysics Data System (ADS)
Lin, Yi-Kuei; Huang, Cheng-Fu; Yeh, Cheng-Ta
2016-04-01
In supply chain management, satisfying customer demand is the most concerned for the manager. However, the goods may rot or be spoilt during delivery owing to natural disasters, inclement weather, traffic accidents, collisions, and so on, such that the intact goods may not meet market demand. This paper concentrates on a stochastic-flow distribution network (SFDN), in which a node denotes a supplier, a transfer station, or a market, while a route denotes a carrier providing the delivery service for a pair of nodes. The available capacity of the carrier is stochastic because the capacity may be partially reserved by other customers. The addressed problem is to evaluate the system reliability, the probability that the SFDN can satisfy the market demand with the spoilage rate under the budget constraint from multiple suppliers to the customer. An algorithm is developed in terms of minimal paths to evaluate the system reliability along with a numerical example to illustrate the solution procedure. A practical case of fruit distribution is presented accordingly to emphasise the management implication of the system reliability.
NASA Astrophysics Data System (ADS)
Sinha, Pampa; Nath, Sudipta
2010-10-01
The main aspects of power system delivery are reliability and quality. If all the customers of a power system get uninterrupted power through the year then the system is considered to be reliable. The term power quality may be referred to as maintaining near sinusoidal voltage at rated frequency at the consumers end. The power component definitions are defined according to the IEEE Standard 1459-2000 both for single phase and three phase unbalanced systems based on Fourier Transform (FFT). In the presence of nonstationary power quality (PQ) disturbances results in accurate values due to its sensitivity to the spectral leakage problem. To overcome these limitations the power quality components are calculated using Discrete Wavelet Transform (DWT). In order to handle the uncertainties associated with electric power systems operations fuzzy logic has been incorporated in this paper. A new power quality index has been introduced here which can assess the power quality under nonstationary disturbances.
Digital avionics systems - Overview of FAA/NASA/industry-wide briefing
NASA Technical Reports Server (NTRS)
Larsen, William E.; Carro, Anthony
1986-01-01
The effects of incorporating digital technology into the design of aircraft on the airworthiness criteria and certification procedures for aircraft are investigated. FAA research programs aimed at providing data for the functional assessment of aircraft which use digital systems for avionics and flight control functions are discussed. The need to establish testing, assurance assessment, and configuration management technologies to insure the reliability of digital systems is discussed; consideration is given to design verification, system performance/robustness, and validation technology.
Dodier, Olivier; Denault, Vincent
2018-01-01
Expert witnesses are sometimes asked to assess the reliability of young witnesses and victims' statements because of their high susceptibility to memory biases. This technical note aims to highlight the relevance of the Griffiths Question Map (GQM) as a professional forensic tool to improve expert witnesses' assessments of young witnesses and victims' testimonies. To do so, this innovative question type assessment grid was used to proceed to an in-depth analysis of the interview of an alleged 13-year-old victim of a sexual assault and two rapes. Overall, the GQM stressed how the interview was mainly conducted in an inappropriate manner. The results are examined with regard to scientific knowledge on young witnesses and victims' memory. Finally, it is argued that expert witnesses in inquisitorial systems might use the GQM while encountering difficulties to fulfill the legal standards for expert evidence in adversarial systems because of the lack of studies regarding its reliability. © 2017 American Academy of Forensic Sciences.
Augmented reality-based electrode guidance system for reliable electroencephalography.
Song, Chanho; Jeon, Sangseo; Lee, Seongpung; Ha, Ho-Gun; Kim, Jonghyun; Hong, Jaesung
2018-05-24
In longitudinal electroencephalography (EEG) studies, repeatable electrode positioning is essential for reliable EEG assessment. Conventional methods use anatomical landmarks as fiducial locations for the electrode placement. Since the landmarks are manually identified, the EEG assessment is inevitably unreliable because of individual variations among the subjects and the examiners. To overcome this unreliability, an augmented reality (AR) visualization-based electrode guidance system was proposed. The proposed electrode guidance system is based on AR visualization to replace the manual electrode positioning. After scanning and registration of the facial surface of a subject by an RGB-D camera, the AR of the initial electrode positions as reference positions is overlapped with the current electrode positions in real time. Thus, it can guide the position of the subsequently placed electrodes with high repeatability. The experimental results with the phantom show that the repeatability of the electrode positioning was improved compared to that of the conventional 10-20 positioning system. The proposed AR guidance system improves the electrode positioning performance with a cost-effective system, which uses only RGB-D camera. This system can be used as an alternative to the international 10-20 system.
Reliability of injury grading systems for patients with blunt splenic trauma.
Olthof, D C; van der Vlies, C H; Scheerder, M J; de Haan, R J; Beenen, L F M; Goslings, J C; van Delden, O M
2014-01-01
The most widely used grading system for blunt splenic injury is the American Association for the Surgery of Trauma (AAST) organ injury scale. In 2007 a new grading system was developed. This 'Baltimore CT grading system' is superior to the AAST classification system in predicting the need for angiography and embolization or surgery. The objective of this study was to assess inter- and intraobserver reliability between radiologists in classifying splenic injury according to both grading systems. CT scans of 83 patients with blunt splenic injury admitted between 1998 and 2008 to an academic Level 1 trauma centre were retrospectively reviewed. Inter and intrarater reliability were expressed in Cohen's or weighted Kappa values. Overall weighted interobserver Kappa coefficients for the AAST and 'Baltimore CT grading system' were respectively substantial (kappa=0.80) and almost perfect (kappa=0.85). Average weighted intraobserver Kappa's values were in the 'almost perfect' range (AAST: kappa=0.91, 'Baltimore CT grading system': kappa=0.81). The present study shows that overall the inter- and intraobserver reliability for grading splenic injury according to the AAST grading system and 'Baltimore CT grading system' are equally high. Because of the integration of vascular injury, the 'Baltimore CT grading system' supports clinical decision making. We therefore recommend use of this system in the classification of splenic injury. Copyright © 2012 Elsevier Ltd. All rights reserved.
A low-cost, tablet-based option for prehospital neurologic assessment: The iTREAT Study.
Chapman Smith, Sherita N; Govindarajan, Prasanthi; Padrick, Matthew M; Lippman, Jason M; McMurry, Timothy L; Resler, Brian L; Keenan, Kevin; Gunnell, Brian S; Mehndiratta, Prachi; Chee, Christina Y; Cahill, Elizabeth A; Dietiker, Cameron; Cattell-Gordon, David C; Smith, Wade S; Perina, Debra G; Solenski, Nina J; Worrall, Bradford B; Southerland, Andrew M
2016-07-05
In this 2-center study, we assessed the technical feasibility and reliability of a low cost, tablet-based mobile telestroke option for ambulance transport and hypothesized that the NIH Stroke Scale (NIHSS) could be performed with similar reliability between remote and bedside examinations. We piloted our mobile telemedicine system in 2 geographic regions, central Virginia and the San Francisco Bay Area, utilizing commercial cellular networks for videoconferencing transmission. Standardized patients portrayed scripted stroke scenarios during ambulance transport and were evaluated by independent raters comparing bedside to remote mobile telestroke assessments. We used a mixed-effects regression model to determine intraclass correlation of the NIHSS between bedside and remote examinations (95% confidence interval). We conducted 27 ambulance runs at both sites and successfully completed the NIHSS for all prehospital assessments without prohibitive technical interruption. The mean difference between bedside (face-to-face) and remote (video) NIHSS scores was 0.25 (1.00 to -0.50). Overall, correlation of the NIHSS between bedside and mobile telestroke assessments was 0.96 (0.92-0.98). In the mixed-effects regression model, there were no statistically significant differences accounting for method of evaluation or differences between sites. Utilizing a low-cost, tablet-based platform and commercial cellular networks, we can reliably perform prehospital neurologic assessments in both rural and urban settings. Further research is needed to establish the reliability and validity of prehospital mobile telestroke assessment in live patients presenting with acute neurologic symptoms. © 2016 American Academy of Neurology.
A low-cost, tablet-based option for prehospital neurologic assessment
Chapman Smith, Sherita N.; Govindarajan, Prasanthi; Padrick, Matthew M.; Lippman, Jason M.; McMurry, Timothy L.; Resler, Brian L.; Keenan, Kevin; Gunnell, Brian S.; Mehndiratta, Prachi; Chee, Christina Y.; Cahill, Elizabeth A.; Dietiker, Cameron; Cattell-Gordon, David C.; Smith, Wade S.; Perina, Debra G.; Solenski, Nina J.; Worrall, Bradford B.
2016-01-01
Objectives: In this 2-center study, we assessed the technical feasibility and reliability of a low cost, tablet-based mobile telestroke option for ambulance transport and hypothesized that the NIH Stroke Scale (NIHSS) could be performed with similar reliability between remote and bedside examinations. Methods: We piloted our mobile telemedicine system in 2 geographic regions, central Virginia and the San Francisco Bay Area, utilizing commercial cellular networks for videoconferencing transmission. Standardized patients portrayed scripted stroke scenarios during ambulance transport and were evaluated by independent raters comparing bedside to remote mobile telestroke assessments. We used a mixed-effects regression model to determine intraclass correlation of the NIHSS between bedside and remote examinations (95% confidence interval). Results: We conducted 27 ambulance runs at both sites and successfully completed the NIHSS for all prehospital assessments without prohibitive technical interruption. The mean difference between bedside (face-to-face) and remote (video) NIHSS scores was 0.25 (1.00 to −0.50). Overall, correlation of the NIHSS between bedside and mobile telestroke assessments was 0.96 (0.92–0.98). In the mixed-effects regression model, there were no statistically significant differences accounting for method of evaluation or differences between sites. Conclusions: Utilizing a low-cost, tablet-based platform and commercial cellular networks, we can reliably perform prehospital neurologic assessments in both rural and urban settings. Further research is needed to establish the reliability and validity of prehospital mobile telestroke assessment in live patients presenting with acute neurologic symptoms. PMID:27281534
Johnson Space Center's Risk and Reliability Analysis Group 2008 Annual Report
NASA Technical Reports Server (NTRS)
Valentine, Mark; Boyer, Roger; Cross, Bob; Hamlin, Teri; Roelant, Henk; Stewart, Mike; Bigler, Mark; Winter, Scott; Reistle, Bruce; Heydorn,Dick
2009-01-01
The Johnson Space Center (JSC) Safety & Mission Assurance (S&MA) Directorate s Risk and Reliability Analysis Group provides both mathematical and engineering analysis expertise in the areas of Probabilistic Risk Assessment (PRA), Reliability and Maintainability (R&M) analysis, and data collection and analysis. The fundamental goal of this group is to provide National Aeronautics and Space Administration (NASA) decisionmakers with the necessary information to make informed decisions when evaluating personnel, flight hardware, and public safety concerns associated with current operating systems as well as with any future systems. The Analysis Group includes a staff of statistical and reliability experts with valuable backgrounds in the statistical, reliability, and engineering fields. This group includes JSC S&MA Analysis Branch personnel as well as S&MA support services contractors, such as Science Applications International Corporation (SAIC) and SoHaR. The Analysis Group s experience base includes nuclear power (both commercial and navy), manufacturing, Department of Defense, chemical, and shipping industries, as well as significant aerospace experience specifically in the Shuttle, International Space Station (ISS), and Constellation Programs. The Analysis Group partners with project and program offices, other NASA centers, NASA contractors, and universities to provide additional resources or information to the group when performing various analysis tasks. The JSC S&MA Analysis Group is recognized as a leader in risk and reliability analysis within the NASA community. Therefore, the Analysis Group is in high demand to help the Space Shuttle Program (SSP) continue to fly safely, assist in designing the next generation spacecraft for the Constellation Program (CxP), and promote advanced analytical techniques. The Analysis Section s tasks include teaching classes and instituting personnel qualification processes to enhance the professional abilities of our analysts as well as performing major probabilistic assessments used to support flight rationale and help establish program requirements. During 2008, the Analysis Group performed more than 70 assessments. Although all these assessments were important, some were instrumental in the decisionmaking processes for the Shuttle and Constellation Programs. Two of the more significant tasks were the Space Transportation System (STS)-122 Low Level Cutoff PRA for the SSP and the Orion Pad Abort One (PA-1) PRA for the CxP. These two activities, along with the numerous other tasks the Analysis Group performed in 2008, are summarized in this report. This report also highlights several ongoing and upcoming efforts to provide crucial statistical and probabilistic assessments, such as the Extravehicular Activity (EVA) PRA for the Hubble Space Telescope service mission and the first fully integrated PRAs for the CxP's Lunar Sortie and ISS missions.
Reliability and cost/worth evaluation of generating systems utilizing wind and solar energy
NASA Astrophysics Data System (ADS)
Bagen
The utilization of renewable energy resources such as wind and solar energy for electric power supply has received considerable attention in recent years due to adverse environmental impacts and fuel cost escalation associated with conventional generation. At the present time, wind and/or solar energy sources are utilized to generate electric power in many applications. Wind and solar energy will become important sources for power generation in the future because of their environmental, social and economic benefits, together with public support and government incentives. The wind and sunlight are, however, unstable and variable energy sources, and behave far differently than conventional sources. Energy storage systems are, therefore, often required to smooth the fluctuating nature of the energy conversion system especially in small isolated applications. The research work presented in this thesis is focused on the development and application of reliability and economic benefits assessment associated with incorporating wind energy, solar energy and energy storage in power generating systems. A probabilistic approach using sequential Monte Carlo simulation was employed in this research and a number of analyses were conducted with regards to the adequacy and economic assessment of generation systems containing wind energy, solar energy and energy storage. The evaluation models and techniques incorporate risk index distributions and different operating strategies associated with diesel generation in small isolated systems. Deterministic and probabilistic techniques are combined in this thesis using a system well-being approach to provide useful adequacy indices for small isolated systems that include renewable energy and energy storage. The concepts presented and examples illustrated in this thesis will help power system planners and utility managers to assess the reliability and economic benefits of utilizing wind energy conversion systems, solar energy conversion systems and energy storage in electric power systems and provide useful input to the managerial decision process.
McGinley, Jennifer L; Goldie, Patricia A; Greenwood, Kenneth M; Olney, Sandra J
2003-02-01
Physical therapists routinely observe gait in clinical practice. The purpose of this study was to determine the accuracy and reliability of observational assessments of push-off in gait after stroke. Eighteen physical therapists and 11 subjects with hemiplegia following a stroke participated in the study. Measurements of ankle power generation were obtained from subjects following stroke using a gait analysis system. Concurrent videotaped gait performances were observed by the physical therapists on 2 occasions. Ankle power generation at push-off was scored as either normal or abnormal using two 11-point rating scales. These observational ratings were correlated with the measurements of peak ankle power generation. A high correlation was obtained between the observational ratings and the measurements of ankle power generation (mean Pearson r=.84). Interobserver reliability was moderately high (mean intraclass correlation coefficient [ICC (2,1)]=.76). Intraobserver reliability also was high, with a mean ICC (2,1) of.89 obtained. Physical therapists were able to make accurate and reliable judgments of push-off in videotaped gait of subjects following stroke using observational assessment. Further research is indicated to explore the accuracy and reliability of data obtained with observational gait analysis as it occurs in clinical practice.
Documentation of pharmaceutical care: Validation of an intervention oriented classification system.
Maes, Karen A; Studer, Helene; Berger, Jérôme; Hersberger, Kurt E; Lampert, Markus L
2017-12-01
During the dispensing process, pharmacists may come across technical and clinical issues requiring a pharmaceutical intervention (PI). An intervention-oriented classification system is a helpful tool to document these PIs in a structured manner. Therefore, we developed the PharmDISC classification system (Pharmacists' Documentation of Interventions in Seamless Care). The aim of this study was to evaluate the PharmDISC system in the daily practice environment (in terms of interrater reliability, appropriateness, interpretability, acceptability, feasibility, and validity); to assess its user satisfaction, the descriptive manual, and the online training; and to explore first implementation aspects. Twenty-one pharmacists from different community pharmacies each classified 30 prescriptions requiring a PI with the PharmDISC system on 5 selected days within 5 weeks. Interrater reliability was determined using model PIs and Fleiss's kappa coefficients (κ) were calculated. User satisfaction was assessed by questionnaire with a 4-point Likert scale. The main outcome measures were interrater reliability (κ); appropriateness, interpretability, validity (ratio of completely classified PIs/all PIs); feasibility, and acceptability (user satisfaction and suggestions). The PharmDISC system reached an average substantial agreement (κ = 0.66). Of documented 519 PIs, 430 (82.9%) were completely classified. Most users found the system comprehensive (median user agreement 3 [2/3.25 quartiles]) and practical (3[2.75/3]). The PharmDISC system raised the awareness regarding drug-related problems for most users (n = 16). To facilitate its implementation, an electronic version that automatically connects to the prescription together with a task manager for PIs needing follow-up was suggested. Barriers could be time expenditure and lack of understanding the benefits. Substantial interrater reliability and acceptable user satisfaction indicate that the PharmDISC system is a valid system to document PIs in daily community pharmacy practice. © 2017 John Wiley & Sons, Ltd.
Cyber Security: Assessing Our Vulnerabilities and Developing an Effective Defense
NASA Astrophysics Data System (ADS)
Spafford, Eugene H.
The number and sophistication of cyberattacks continues to increase, but no national policy is in place to confront them. Critical systems need to be built on secure foundations, rather than the cheapest general-purpose platform. A program that combines education in cyber security, increasing resources for law enforcement, development of reliable systems for critical applications, and expanding research support in multiple areas of security and reliability is essential to combat risks that are far beyond the nuisances of spam email and viruses, and involve widespread espionage, theft, and attacks on essential services.
Risk assessment for construction projects of transport infrastructure objects
NASA Astrophysics Data System (ADS)
Titarenko, Boris
2017-10-01
The paper analyzes and compares different methods of risk assessment for construction projects of transport objects. The management of such type of projects demands application of special probabilistic methods due to large level of uncertainty of their implementation. Risk management in the projects requires the use of probabilistic and statistical methods. The aim of the work is to develop a methodology for using traditional methods in combination with robust methods that allow obtaining reliable risk assessments in projects. The robust approach is based on the principle of maximum likelihood and in assessing the risk allows the researcher to obtain reliable results in situations of great uncertainty. The application of robust procedures allows to carry out a quantitative assessment of the main risk indicators of projects when solving the tasks of managing innovation-investment projects. Calculation of damage from the onset of a risky event is possible by any competent specialist. And an assessment of the probability of occurrence of a risky event requires the involvement of special probabilistic methods based on the proposed robust approaches. Practice shows the effectiveness and reliability of results. The methodology developed in the article can be used to create information technologies and their application in automated control systems for complex projects.
The purpose of the field demonstration program is to gather technically reliable cost and performance information on selected condition assessment technologies under defined field conditions. The selected technologies include zoom camera, electro-scan (FELL-41), and a multi-sens...
Proactive assessment of accident risk to improve safety on a system of freeways : [research brief].
DOT National Transportation Integrated Search
2012-05-01
As traffic safety on freeways continues to be a growing concern, much progress has been made in shifting from reactive (incident detection) to proactive (real-time crash risk assessment) traffic strategies. Reliable models that can take in real-time ...
Fatigue reliability of deck structures subjected to correlated crack growth
NASA Astrophysics Data System (ADS)
Feng, G. Q.; Garbatov, Y.; Guedes Soares, C.
2013-12-01
The objective of this work is to analyse fatigue reliability of deck structures subjected to correlated crack growth. The stress intensity factors of the correlated cracks are obtained by finite element analysis and based on which the geometry correction functions are derived. The Monte Carlo simulations are applied to predict the statistical descriptors of correlated cracks based on the Paris-Erdogan equation. A probabilistic model of crack growth as a function of time is used to analyse the fatigue reliability of deck structures accounting for the crack propagation correlation. A deck structure is modelled as a series system of stiffened panels, where a stiffened panel is regarded as a parallel system composed of plates and are longitudinal. It has been proven that the method developed here can be conveniently applied to perform the fatigue reliability assessment of structures subjected to correlated crack growth.
Reliability assessments in qualitative health promotion research.
Cook, Kay E
2012-03-01
This article contributes to the debate about the use of reliability assessments in qualitative research in general, and health promotion research in particular. In this article, I examine the use of reliability assessments in qualitative health promotion research in response to health promotion researchers' commonly held misconception that reliability assessments improve the rigor of qualitative research. All qualitative articles published in the journal Health Promotion International from 2003 to 2009 employing reliability assessments were examined. In total, 31.3% (20/64) articles employed some form of reliability assessment. The use of reliability assessments increased over the study period, ranging from <20% in 2003/2004 to 50% and above in 2008/2009, while at the same time the total number of qualitative articles decreased. The articles were then classified into four types of reliability assessments, including the verification of thematic codes, the use of inter-rater reliability statistics, congruence in team coding and congruence in coding across sites. The merits of each type were discussed, with the subsequent discussion focusing on the deductive nature of reliable thematic coding, the limited depth of immediately verifiable data and the usefulness of such studies to health promotion and the advancement of the qualitative paradigm.
Reliability-Based Life Assessment of Stirling Convertor Heater Head
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Halford, Gary R.; Korovaichuk, Igor
2004-01-01
Onboard radioisotope power systems being developed and planned for NASA's deep-space missions require reliable design lifetimes of up to 14 yr. The structurally critical heater head of the high-efficiency Stirling power convertor has undergone extensive computational analysis of operating temperatures, stresses, and creep resistance of the thin-walled Inconel 718 bill of material. A preliminary assessment of the effect of uncertainties in the material behavior was also performed. Creep failure resistance of the thin-walled heater head could show variation due to small deviations in the manufactured thickness and in uncertainties in operating temperature and pressure. Durability prediction and reliability of the heater head are affected by these deviations from nominal design conditions. Therefore, it is important to include the effects of these uncertainties in predicting the probability of survival of the heater head under mission loads. Furthermore, it may be possible for the heater head to experience rare incidences of small temperature excursions of short duration. These rare incidences would affect the creep strain rate and, therefore, the life. This paper addresses the effects of such rare incidences on the reliability. In addition, the sensitivities of variables affecting the reliability are quantified, and guidelines developed to improve the reliability are outlined. Heater head reliability is being quantified with data from NASA Glenn Research Center's accelerated benchmark testing program.
Cyber Threat Assessment of Uplink and Commanding System for Mission Operation
NASA Technical Reports Server (NTRS)
Ko, Adans Y.; Tan, Kymie M. C.; Cilloniz-Bicchi, Ferner; Faris, Grant
2014-01-01
Most of today's Mission Operations Systems (MOS) rely on Ground Data System (GDS) segment to mitigate cyber security risks. Unfortunately, IT security design is done separately from the design of GDS' mission operational capabilities. This incoherent practice leaves many security vulnerabilities in the system without any notice. This paper describes a new way to system engineering MOS, to include cyber threat risk assessments throughout the MOS development cycle, without this, it is impossible to design a dependable and reliable MOS to meet today's rapid changing cyber threat environment.
Sevdalis, Nick; Undre, Shabnam; Henry, Janet; Sydney, Elaine; Koutantji, Mary; Darzi, Ara; Vincent, Charles A
2009-09-01
The recent emergence of the Systems Approach to the safety and quality of surgical care has triggered individual and team skills training modules for surgeons and anaesthetists and relevant observational assessment tools have been developed. To develop an observational tool that captures operating room (OR) nurses' technical skill and can be used for assessment and training. The Imperial College Assessment of Technical Skills for Nurses (ICATS-N) assesses (i) gowning and gloving, (ii) setting up instrumentation, (iii) draping, and (iv) maintaining sterility. Three to five observable behaviours have been identified for each skill and are rated on 1-6 scales. Feasibility and aspects of reliability and validity were assessed in 20 simulation-based crisis management training modules for trainee nurses and doctors, carried out in a Simulated Operating Room. The tool was feasible to use in the context of simulation-based training. Satisfactory reliability (Cronbach alpha) was obtained across trainers' and trainees' scores (analysed jointly and separately). Moreover, trainer nurse's ratings of the four skills correlated positively, thus indicating adequate content validity. Trainer's and trainees' ratings did not correlate. Assessment of OR nurses' technical skill is becoming a training priority. The present evidence suggests that the ICATS-N could be considered for use as an assessment/training tool for junior OR nurses.
A Web-Based System for Bayesian Benchmark Dose Estimation.
Shao, Kan; Shapiro, Andrew J
2018-01-11
Benchmark dose (BMD) modeling is an important step in human health risk assessment and is used as the default approach to identify the point of departure for risk assessment. A probabilistic framework for dose-response assessment has been proposed and advocated by various institutions and organizations; therefore, a reliable tool is needed to provide distributional estimates for BMD and other important quantities in dose-response assessment. We developed an online system for Bayesian BMD (BBMD) estimation and compared results from this software with U.S. Environmental Protection Agency's (EPA's) Benchmark Dose Software (BMDS). The system is built on a Bayesian framework featuring the application of Markov chain Monte Carlo (MCMC) sampling for model parameter estimation and BMD calculation, which makes the BBMD system fundamentally different from the currently prevailing BMD software packages. In addition to estimating the traditional BMDs for dichotomous and continuous data, the developed system is also capable of computing model-averaged BMD estimates. A total of 518 dichotomous and 108 continuous data sets extracted from the U.S. EPA's Integrated Risk Information System (IRIS) database (and similar databases) were used as testing data to compare the estimates from the BBMD and BMDS programs. The results suggest that the BBMD system may outperform the BMDS program in a number of aspects, including fewer failed BMD and BMDL calculations and estimates. The BBMD system is a useful alternative tool for estimating BMD with additional functionalities for BMD analysis based on most recent research. Most importantly, the BBMD has the potential to incorporate prior information to make dose-response modeling more reliable and can provide distributional estimates for important quantities in dose-response assessment, which greatly facilitates the current trend for probabilistic risk assessment. https://doi.org/10.1289/EHP1289.
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Nicholas, Kevin; Sparkes, Valerie; Sheeran, Liba; Davies, Jennifer L
2018-01-01
The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 ± 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater) reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements. PMID:29495600
Patient-Centered Technological Assessment and Monitoring of Depression for Low-Income Patients
Wu, Shinyi; Vidyanti, Irene; Liu, Pai; Hawkins, Caitlin; Ramirez, Magaly; Guterman, Jeffrey; Gross-Schulman, Sandra; Sklaroff, Laura Myerchin; Ell, Kathleen
2014-01-01
Depression is a significant challenge for ambulatory care because it worsens health status and outcomes, increases health care utilizations and costs, and elevates suicide risk. An automatic telephonic assessment (ATA) system that links with tasks and alerts to providers may improve quality of depression care and increase provider productivity. We used ATA system in a trial to assess and monitor depressive symptoms of 444 safety-net primary care patients with diabetes. We assessed system properties, evaluated preliminary clinical outcomes, and estimated cost savings. The ATA system is feasible, reliable, valid, safe, and likely cost-effective for depression screening and monitoring for low-income primary care population. PMID:24525531
Development and Calibration of an Item Bank for PE Metrics Assessments: Standard 1
ERIC Educational Resources Information Center
Zhu, Weimo; Fox, Connie; Park, Youngsik; Fisette, Jennifer L.; Dyson, Ben; Graber, Kim C.; Avery, Marybell; Franck, Marian; Placek, Judith H.; Rink, Judy; Raynes, De
2011-01-01
The purpose of this study was to develop and calibrate an assessment system, or bank, using the latest measurement theories and methods to promote valid and reliable student assessment in physical education. Using an anchor-test equating design, a total of 30 items or assessments were administered to 5,021 (2,568 boys and 2,453 girls) students in…
Phuong Hoa, Nguyen; Walker, Sue M.; Hill, Peter S.; Rao, Chalapati
2018-01-01
Background Mortality statistics form a crucial component of national Health Management Information Systems (HMIS). However, there are limitations in the availability and quality of mortality data at national level in Viet Nam. This study assessed the completeness of recorded deaths and the reliability of recorded causes of death (COD) in the A6 death registers in the national routine HMIS in Viet Nam. Methodology and findings 1477 identified deaths in 2014 were reviewed in two provinces. A capture-recapture method was applied to assess the completeness of the A6 death registers. 1365 household verbal autopsy (VA) interviews were successfully conducted, and these were reviewed by physicians who assigned multiple and underlying cause of death (UCOD). These UCODs from VA were then compared with the CODs recorded in the A6 death registers, using kappa scores to assess the reliability of the A6 death register diagnoses. The overall completeness of the A6 death registers in the two provinces was 89.3% (95%CI: 87.8–90.8). No COD recorded in the A6 death registers demonstrated good reliability. There is very low reliability in recording of cardiovascular deaths (kappa for stroke = 0.47 and kappa for ischaemic heart diseases = 0.42) and diabetes (kappa = 0.33). The reporting of deaths due to road traffic accidents, HIV and some cancers are at a moderate level of reliability with kappa scores ranging between 0.57–0.69 (p<0.01). VA methods identify more specific COD than the A6 death registers, and also allow identification of multiple CODs. Conclusions The study results suggest that data completeness in HMIS A6 death registers in the study sample of communes was relatively high (nearly 90%), but triangulation with death records from other sources would improve the completeness of this system. Further, there is an urgent need to enhance the reliability of COD recorded in the A6 death registers, for which VA methods could be effective. Focussed consultation among stakeholders is needed to develop a suitable mechanism and process for integrating VA methods into the national routine HMIS A6 death registers in Viet Nam. PMID:29370191
An Online Risk Monitor System (ORMS) to Increase Safety and Security Levels in Industry
NASA Astrophysics Data System (ADS)
Zubair, M.; Rahman, Khalil Ur; Hassan, Mehmood Ul
2013-12-01
The main idea of this research is to develop an Online Risk Monitor System (ORMS) based on Living Probabilistic Safety Assessment (LPSA). The article highlights the essential features and functions of ORMS. The basic models and modules such as, Reliability Data Update Model (RDUM), running time update, redundant system unavailability update, Engineered Safety Features (ESF) unavailability update and general system update have been described in this study. ORMS not only provides quantitative analysis but also highlights qualitative aspects of risk measures. ORMS is capable of automatically updating the online risk models and reliability parameters of equipment. ORMS can support in the decision making process of operators and managers in Nuclear Power Plants.
Using benchmarks for radiation testing of microprocessors and FPGAs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quinn, Heather; Robinson, William H.; Rech, Paolo
Performance benchmarks have been used over the years to compare different systems. These benchmarks can be useful for researchers trying to determine how changes to the technology, architecture, or compiler affect the system's performance. No such standard exists for systems deployed into high radiation environments, making it difficult to assess whether changes in the fabrication process, circuitry, architecture, or software affect reliability or radiation sensitivity. In this paper, we propose a benchmark suite for high-reliability systems that is designed for field-programmable gate arrays and microprocessors. As a result, we describe the development process and report neutron test data for themore » hardware and software benchmarks.« less
Using benchmarks for radiation testing of microprocessors and FPGAs
Quinn, Heather; Robinson, William H.; Rech, Paolo; ...
2015-12-17
Performance benchmarks have been used over the years to compare different systems. These benchmarks can be useful for researchers trying to determine how changes to the technology, architecture, or compiler affect the system's performance. No such standard exists for systems deployed into high radiation environments, making it difficult to assess whether changes in the fabrication process, circuitry, architecture, or software affect reliability or radiation sensitivity. In this paper, we propose a benchmark suite for high-reliability systems that is designed for field-programmable gate arrays and microprocessors. As a result, we describe the development process and report neutron test data for themore » hardware and software benchmarks.« less
Interrater Reliability of the Power Mobility Road Test in the Virtual Reality-Based Simulator-2.
Kamaraj, Deepan C; Dicianno, Brad E; Mahajan, Harshal P; Buhari, Alhaji M; Cooper, Rory A
2016-07-01
To assess interrater reliability of the Power Mobility Road Test (PMRT) when administered through the Virtual Reality-based SIMulator-version 2 (VRSIM-2). Within-subjects repeated-measures design. Participants interacted with VRSIM-2 through 2 display options (desktop monitor vs immersive virtual reality screens) using 2 control interfaces (roller system vs conventional movement-sensing joystick), providing 4 different driving scenarios (driving conditions 1-4). Participants performed 3 virtual driving sessions for each of the 2 display screens and 1 session through a real-world driving course (driving condition 5). The virtual PMRT was conducted in a simulated indoor office space, and an equivalent course was charted in an open space for the real-world assessment. After every change in driving condition, participants completed a self-reported workload assessment questionnaire, the Task Load Index, developed by the National Aeronautics and Space Administration. A convenience sample of electric-powered wheelchair (EPW) athletes (N=21) recruited at the 31st National Veterans Wheelchair Games. Not applicable. Total composite PMRT score. The PMRT had high interrater reliability (intraclass correlation coefficient [ICC]>.75) between the 2 raters in all 5 driving conditions. Post hoc analyses revealed that the reliability analyses had >80% power to detect high ICCs in driving conditions 1 and 4. The PMRT has high interrater reliability in conditions 1 and 4 and could be used to assess EPW driving performance virtually in VRSIM-2. However, further psychometric assessment is necessary to assess the feasibility of administering the PMRT using the different interfaces of VRSIM-2. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Marques, Alda; Almeida, Sara; Carvalho, Joana; Cruz, Joana; Oliveira, Ana; Jácome, Cristina
2016-12-01
To assess the reliability, validity, and ability to identify fall status of the Balance Evaluation Systems Test (BESTest), Mini-BESTest, and Brief-BESTest, compared with the Berg Balance Scale (BBS), in older people living in the community. Cross-sectional. Community centers. Older adults (N=122; mean age ± SD, 76±9y). Not applicable. Participants reported on falls history in the preceding year and completed the Activities-Specific Balance Confidence (ABC) Scale. The BBS, BESTest, and the Five Times Sit-To-Stand Test were administered. Interrater (2 physiotherapists) and test-retest relative (48-72h) and absolute reliabilities were explored with the intraclass correlation coefficient (ICC) equation (2,1) and the Bland and Altman method. Minimal detectable changes at the 95% confidence level (MDC 95 ) were established. Validity was assessed by correlating the balance tests with each other and with the ABC Scale (Spearman correlation coefficients-ρ). Receiver operating characteristics assessed the ability of each balance test to differentiate between people with and without a history of falls. All balance tests presented good to excellent interrater (ICC=.71-.93) and test-retest (ICC=.50-.82) relative reliability, with no evidence of bias. MDC 95 values were 4.6, 9, 3.8, and 4.1 points for the BBS, BESTest, Mini-BESTest, and Brief-BESTest, respectively. All tests were significantly correlated with each other (ρ=.83-.96) and with the ABC Scale (ρ=.46-.61). Acceptable ability to identify fall status (areas under the curve, .71-.78) was found for all tests. Cutoff points were 48.5, 82, 19.5, and 12.5 points for the BBS, BESTest, Mini-BESTest, and Brief-BESTest, respectively. All balance tests are reliable, valid, and able to identify fall status in older people living in the community. Therefore, the choice of which test to use will depend on the level of balance impairment, purpose, and time availability. Copyright © 2016. Published by Elsevier Inc.
The Effect of Incorrect Reliability Information on Expectations, Perceptions, and Use of Automation.
Barg-Walkow, Laura H; Rogers, Wendy A
2016-03-01
We examined how providing artificially high or low statements about automation reliability affected expectations, perceptions, and use of automation over time. One common method of introducing automation is providing explicit statements about the automation's capabilities. Research is needed to understand how expectations from such introductions affect perceptions and use of automation. Explicit-statement introductions were manipulated to set higher-than (90%), same-as (75%), or lower-than (60%) levels of expectations in a dual-task scenario with 75% reliable automation. Two experiments were conducted to assess expectations, perceptions, compliance, reliance, and task performance over (a) 2 days and (b) 4 days. The baseline assessments showed initial expectations of automation reliability matched introduced levels of expectation. For the duration of each experiment, the lower-than groups' perceptions were lower than the actual automation reliability. However, the higher-than groups' perceptions were no different from actual automation reliability after Day 1 in either study. There were few differences between groups for automation use, which generally stayed the same or increased with experience using the system. Introductory statements describing artificially low automation reliability have a long-lasting impact on perceptions about automation performance. Statements including incorrect automation reliability do not appear to affect use of automation. Introductions should be designed according to desired outcomes for expectations, perceptions, and use of the automation. Low expectations have long-lasting effects. © 2015, Human Factors and Ergonomics Society.
Quantitative Accelerated Life Testing of MEMS Accelerometers.
Bâzu, Marius; Gălăţeanu, Lucian; Ilian, Virgil Emil; Loicq, Jerome; Habraken, Serge; Collette, Jean-Paul
2007-11-20
Quantitative Accelerated Life Testing (QALT) is a solution for assessing thereliability of Micro Electro Mechanical Systems (MEMS). A procedure for QALT is shownin this paper and an attempt to assess the reliability level for a batch of MEMSaccelerometers is reported. The testing plan is application-driven and contains combinedtests: thermal (high temperature) and mechanical stress. Two variants of mechanical stressare used: vibration (at a fixed frequency) and tilting. Original equipment for testing at tiltingand high temperature is used. Tilting is appropriate as application-driven stress, because thetilt movement is a natural environment for devices used for automotive and aerospaceapplications. Also, tilting is used by MEMS accelerometers for anti-theft systems. The testresults demonstrated the excellent reliability of the studied devices, the failure rate in the"worst case" being smaller than 10 -7 h -1 .
A Methodology for Quantifying Certain Design Requirements During the Design Phase
NASA Technical Reports Server (NTRS)
Adams, Timothy; Rhodes, Russel
2005-01-01
A methodology for developing and balancing quantitative design requirements for safety, reliability, and maintainability has been proposed. Conceived as the basis of a more rational approach to the design of spacecraft, the methodology would also be applicable to the design of automobiles, washing machines, television receivers, or almost any other commercial product. Heretofore, it has been common practice to start by determining the requirements for reliability of elements of a spacecraft or other system to ensure a given design life for the system. Next, safety requirements are determined by assessing the total reliability of the system and adding redundant components and subsystems necessary to attain safety goals. As thus described, common practice leaves the maintainability burden to fall to chance; therefore, there is no control of recurring costs or of the responsiveness of the system. The means that have been used in assessing maintainability have been oriented toward determining the logistical sparing of components so that the components are available when needed. The process established for developing and balancing quantitative requirements for safety (S), reliability (R), and maintainability (M) derives and integrates NASA s top-level safety requirements and the controls needed to obtain program key objectives for safety and recurring cost (see figure). Being quantitative, the process conveniently uses common mathematical models. Even though the process is shown as being worked from the top down, it can also be worked from the bottom up. This process uses three math models: (1) the binomial distribution (greaterthan- or-equal-to case), (2) reliability for a series system, and (3) the Poisson distribution (less-than-or-equal-to case). The zero-fail case for the binomial distribution approximates the commonly known exponential distribution or "constant failure rate" distribution. Either model can be used. The binomial distribution was selected for modeling flexibility because it conveniently addresses both the zero-fail and failure cases. The failure case is typically used for unmanned spacecraft as with missiles.
Validating Neuro-QoL short forms and targeted scales with people who have multiple sclerosis.
Miller, Deborah M; Bethoux, Francois; Victorson, David; Nowinski, Cindy J; Buono, Sarah; Lai, Jin-Shei; Wortman, Katy; Burns, James L; Moy, Claudia; Cella, David
2016-05-01
Multiple sclerosis (MS) is a chronic, progressive, and disabling disease of the central nervous system with dramatic variations in the combination and severity of symptoms it can produce. The lack of reliable disease-specific health-related quality of life (HRQL) measures for use in clinical trials prompted the development of the Neurology Quality of Life (Neuro-QOL) instrument, which includes 13 scales that assess physical, emotional, cognitive, and social domains, for use in a variety of neurological illnesses. The objective of this research paper is to conduct an initial assessment of the reliability and validation of the Neuro-QOL short forms (SFs) in MS. We assessed reliability, concurrent validity, known groups validity, and responsiveness between cross-sectional and longitudinal data in 161 recruited MS patients. Internal consistency was high for all measures (α = 0.81-0.95) and ICCs were within the acceptable range (0.76-0.91); concurrent and known groups validity were highest with the Global HRQL question. Longitudinal assessment was limited by the lack of disease progression in the group. The Neuro-QOL SFs demonstrate good internal consistency, test-re-test reliability, and concurrent and known groups validity in this MS population, supporting the validity of Neuro-QOL in adults with MS. © The Author(s), 2015.
Crossley, Jim; Eiser, Christine; Davies, Helena A
2005-08-01
Only a patient and his or her family can judge many of the most important aspects of the doctor-patient interaction. This study evaluates the feasibility and reliability of children and their families assessing the quality of paediatricians' interactions using a rating instrument developed specifically for this purpose. A reliability analysis using generalisability theory on the ratings from 352 doctor-patient interactions across different speciality clinics. Ratings were normally distributed. They were highest for 'overall' performance, and lowest for giving time to discuss the families' agenda. An appropriate sample of adults' ratings provided a reliable score (G = 0.7 with 15 raters), but children's ratings were too idiosyncratic to be reproducible (G = 0.36 with 15 raters). CONCLUSIONS AND FURTHER WORK: Accompanying adults can provide reliable ratings of doctors' interactions with children. Because an adult is usually present at the consultation their ratings provide a highly feasible and authentic approach. Sampling doctors' interactions from different clinics and with patients of both genders provides a universal picture of performance. The method is ideal to measure performance for in-training assessment or revalidation. Further work is in progress to evaluate the educational impact of feeding ratings back to the doctors being assessed, and their use in a range of clinical contexts.
Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Tresadern, Philip; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L
2017-07-01
Our aim was to assess the reliability of nailfold capillary assessment in terms of image evaluability, image severity grade ('normal', 'early', 'active', 'late'), capillary density, capillary (apex) width, and presence of giant capillaries, and also to gain further insight into differences in these parameters between patients with systemic sclerosis (SSc), patients with primary Raynaud's phenomenon (PRP) and healthy control subjects. Videocapillaroscopy images (magnification 300×) were acquired from all 10 digits from 173 participants: 101 patients with SSc, 22 with PRP and 50 healthy controls. Ten capillaroscopy experts from 7 European centres evaluated the images. Custom image mark-up software allowed extraction of the following outcome measures: overall grade ('normal', 'early', 'active', 'late', 'non-specific', or 'ungradeable'), capillary density (vessels/mm), mean vessel apical width, and presence of giant capillaries. Observers analysed a median of 129 images each. Evaluability (i.e. the availability of measures) varied across outcome measures (e.g. 73.0% for density and 46.2% for overall grade in patients with SSc). Intra-observer reliability for evaluability was consistently higher than inter- (e.g. for density, intra-class correlation coefficient [ICC] was 0.71 within and 0.14 between observers). Conditional on evaluability, both intra- and inter-observer reliability were high for grade (ICC 0.93 and 0.78 respectively), density (0.91 and 0.64) and width (0.91 and 0.85). Evaluability is one of the major challenges in assessing nailfold capillaries. However, when images are evaluable, the high intra- and inter-reliabilities suggest that overall image grade, capillary density and apex width have potential as outcome measures in longitudinal studies. Copyright © 2017 Elsevier Inc. All rights reserved.
Tankevicius, Gediminas; Lankaite, Doanata; Krisciunas, Aleksandras
2013-08-01
The lack of knowledge about isometric ankle testing indicates the need for research in this area. to assess test-retest reliability and to determine the optimal position for isometric ankle-eversion and -inversion testing. Test-retest reliability study. Isometric ankle eversion and inversion were assessed in 3 different dynamometer foot-plate positions: 0°, 7°, and 14° of inversion. Two maximal repetitions were performed at each angle. Both limbs were tested (40 ankles in total). The test was performed 2 times with a period of 7 d between the tests. University hospital. The study was carried out on 20 healthy athletes with no history of ankle sprains. Reliability was assessed using intraclass correlation coefficient (ICC2,1); minimal detectable change (MDC) was calculated using a 95% confidence interval. Paired t test was used to measure statistically significant changes, and P <.05 was considered statistically significant. Eversion and inversion peak torques showed high ICCs in all 3 angles (ICC values .87-.96, MDC values 3.09-6.81 Nm). Eversion peak torque was the smallest when testing at the 0° angle and gradually increased, reaching maximum values at 14° angle. The increase of eversion peak torque was statistically significant at 7 ° and 14° of inversion. Inversion peak torque showed an opposite pattern-it was the smallest when measured at the 14° angle and increased at the other 2 angles; statistically significant changes were seen only between measures taken at 0° and 14°. Isometric eversion and inversion testing using the Biodex 4 Pro system is a reliable method. The authors suggest that the angle of 7° of inversion is the best for isometric eversion and inversion testing.
NASA Technical Reports Server (NTRS)
Gerke, R. David; Sandor, Mike; Agarwal, Shri; Moor, Andrew F.; Cooper, Kim A.
2000-01-01
Engineers within the commercial and aerospace industries are using trade-off and risk analysis to aid in reducing spacecraft system cost while increasing performance and maintaining high reliability. In many cases, Commercial Off-The-Shelf (COTS) components, which include Plastic Encapsulated Microcircuits (PEMs), are candidate packaging technologies for spacecrafts due to their lower cost, lower weight and enhanced functionality. Establishing and implementing a parts program that effectively and reliably makes use of these potentially less reliable, but state-of-the-art devices, has become a significant portion of the job for the parts engineer. Assembling a reliable high performance electronic system, which includes COTS components, requires that the end user assume a risk. To minimize the risk involved, companies have developed methodologies by which they use accelerated stress testing to assess the product and reduce the risk involved to the total system. Currently, there are no industry standard procedures for accomplishing this risk mitigation. This paper will present the approaches for reducing the risk of using PEMs devices in space flight systems as developed by two independent Laboratories. The JPL procedure involves primarily a tailored screening with accelerated stress philosophy while the APL procedure is primarily, a lot qualification procedure. Both Laboratories successfully have reduced the risk of using the particular devices for their respective systems and mission requirements.
Gräff, Ingo; Goldschmidt, Bernd; Glien, Procula; Bogdanow, Manuela; Fimmers, Rolf; Hoeft, Andreas; Kim, Se-Chan; Grigutsch, Daniel
2014-01-01
Background The German Version of the Manchester Triage System (MTS) has found widespread use in EDs across German-speaking Europe. Studies about the quality criteria validity and reliability of the MTS currently only exist for the English-language version. Most importantly, the content of the German version differs from the English version with respect to presentation diagrams and change indicators, which have a significant impact on the category assigned. This investigation offers a preliminary assessment in terms of validity and inter-rater reliability of the German MTS. Methods Construct validity of assigned MTS level was assessed based on comparisons to hospitalization (general / intensive care), mortality, ED and hospital length of stay, level of prehospital care and number of invasive diagnostics. A sample of 45,469 patients was used. Inter-rater agreement between an expert and triage nurses (reliability) was calculated separately for a subset group of 167 emergency patients. Results For general hospital admission the area under the curve (AUC) of the receiver operating characteristic was 0.749; for admission to ICU it was 0.871. An examination of MTS-level and number of deceased patients showed that the higher the priority derived from MTS, the higher the number of deaths (p<0.0001 / χ2 Test). There was a substantial difference in the 30-day survival among the 5 MTS categories (p<0.0001 / log-rank test).The AUC for the predict 30-day mortality was 0.613. Categories orange and red had the highest numbers of heart catheter and endoscopy. Category red and orange were mostly accompanied by an emergency physician, whereas categories blue and green were walk-in patients. Inter-rater agreement between expert triage nurses was almost perfect (κ = 0.954). Conclusion The German version of the MTS is a reliable and valid instrument for a first assessment of emergency patients in the emergency department. PMID:24586477
Human Reliability Assessments: Using the Past (Shuttle) to Predict the Future (ORION)
NASA Technical Reports Server (NTRS)
Mott, Diana L.; Bigler, Mark A.
2017-01-01
NASA uses two HRA assessment methodologies. The first is a simplified method which is based on how much time is available to complete the action, with consideration included for environmental and personal factors that could influence the human's reliability. This method is expected to provide a conservative value or placeholder as a preliminary estimate. This preliminary estimate is used to determine which placeholder needs a more detailed assessment. The second methodology is used to develop a more detailed human reliability assessment on the performance of critical human actions. This assessment needs to consider more than the time available, this would include factors such as: the importance of the action, the context, environmental factors, potential human stresses, previous experience, training, physical design interfaces, available procedures/checklists and internal human stresses. The more detailed assessment is still expected to be more realistic than that based primarily on time available. When performing an HRA on a system or process that has an operational history, we have information specific to the task based on this history and experience. In the case of a PRA model that is based on a new design and has no operational history, providing a "reasonable" assessment of potential crew actions becomes more problematic. In order to determine what is expected of future operational parameters, the experience from individuals who had relevant experience and were familiar with the system and process previously implemented by NASA was used to provide the "best" available data. Personnel from Flight Operations, Flight Directors, Launch Test Directors, Control Room Console Operators and Astronauts were all interviewed to provide a comprehensive picture of previous NASA operations. Verification of the assumptions and expectations expressed in the assessments will be needed when the procedures, flight rules and operational requirements are developed and then finalized.
e-Health readiness assessment factors and measuring tools: A systematic review.
Yusif, Salifu; Hafeez-Baig, Abdul; Soar, Jeffrey
2017-11-01
The evolving, adoption and high failure nature of health information technology (HIT)/IS/T systems requires effective readiness assessment to avert increasing failures while increasing system benefits. However, literature on HIT readiness assessment is myriad and fragmented. This review bares the contours of the available literature concluding in a set of manageable and usable recommendations for policymakers, researchers, individuals and organizations intending to assess readiness for any HIT implementation. Identify studies, analyze readiness factors and offer recommendations. Published articles 1995-2016 were searched using Medline/PubMed, Cinahl, Web of Science, PsychInfo, ProQuest. Studies were included if they were assessing IS/T/mHealth readiness in the context of HIT. Articles not written in English were excluded. Themes that emerged in the process of the data synthesis were thematically analysed and interpreted. Analyzed themes were found across 63 articles. In accordance with their prevalence of use, they included but not limited to "Technological readiness", 30 (46%); "Core/Need/Motivational readiness", 23 (37%); "Acceptance and use readiness", 19 (29%); "Organizational readiness", 20 (21%); "IT skills/Training/Learning readiness" (18%), "Engagement readiness", 16 (24%) and "Societal readiness" (14%). Despite their prevalence in use, "Technological readiness", "Motivational readiness" and "Engagement readiness" all had myriad and unreliable measuring tools. Core readiness had relatively reliable measuring tools, which repeatedly been used in various readiness assessment studies CONCLUSION: Thus, there is the need for reliable measuring tools for even the most commonly used readiness assessment factors/constructs: Core readiness, Engagement and buy-ins readiness, Technological readiness and IT Skills readiness as this could serve as an immediate step in conducting effective/reliable e-Health readiness assessment, which could lead to reduced HIT implementation failures. Copyright © 2017 Elsevier B.V. All rights reserved.
Standardized quality-assessment system to evaluate pressure ulcer care in the nursing home.
Bates-Jensen, Barbara M; Cadogan, Mary; Jorge, Jennifer; Schnelle, John F
2003-09-01
To demonstrate reliability and feasibility of a standardized protocol to assess and score quality indicators relevant to pressure ulcer (PU) care processes in nursing homes (NHs). Descriptive. Eight NHs. One hundred ninety-one NH residents for whom the PU Resident Assessment Protocol of the Minimum Data Set was initiated. Nine quality indicators (two related to screening and prevention of PU, two focused on assessment, and five addressing management) were scored using medical record data, direct human observation, and wireless thigh monitor observation data. Feasibility and reliability of medical record, observation, and thigh monitor protocols were determined. The percentage of participants who passed each of the indicators, indicating care consistent with practice guidelines, ranged from 0% to 98% across all indicators. In general, participants in NHs passed fewer indicators and had more problems with medical record accuracy before a PU was detected (screening/prevention indicators) than they did once an ulcer was documented (assessment and management indicators). Reliability of the medical record protocol showed kappa statistics ranging from 0.689 to 1.00 and percentage agreement from 80% to 100%. Direct observation protocols yielded kappa statistics of 0.979 and 0.928. Thigh monitor protocols showed kappa statistics ranging from 0.609 to 0.842. Training was variable, with the observation protocol requiring 1 to 2 hours, medical records requiring joint review of 20 charts with average time to complete the review of 20 minutes, and the thigh monitor data requiring 1 week for training in data preparation and interpretation. The standardized quality assessment system generated scores for nine PU quality indicators with good reliability and provided explicit scoring rules that permit reproducible conclusions about PU care. The focus of the indicators on care processes that are under the control of NH staff made the protocol useful for external survey and internal quality improvement purposes, and the thigh monitor observational technology provided a method for monitoring repositioning care processes that were otherwise difficult to monitor and manage.
Klein, Britt; Meyer, Denny; Austin, David William; Abbott, Jo-Anne M
2015-01-01
Background Internet-based assessment has the potential to assist with the diagnosis of mental health disorders and overcome the barriers associated with traditional services (eg, cost, stigma, distance). Further to existing online screening programs available, there is an opportunity to deliver more comprehensive and accurate diagnostic tools to supplement the assessment and treatment of mental health disorders. Objective The aim was to evaluate the diagnostic criterion validity and test-retest reliability of the electronic Psychological Assessment System (e-PASS), an online, self-report, multidisorder, clinical assessment and referral system. Methods Participants were 616 adults residing in Australia, recruited online, and representing prospective e-PASS users. Following e-PASS completion, 158 participants underwent a telephone-administered structured clinical interview and 39 participants repeated the e-PASS within 25 days of initial completion. Results With structured clinical interview results serving as the gold standard, diagnostic agreement with the e-PASS varied considerably from fair (eg, generalized anxiety disorder: κ=.37) to strong (eg, panic disorder: κ=.62). Although the e-PASS’ sensitivity also varied (0.43-0.86) the specificity was generally high (0.68-1.00). The e-PASS sensitivity generally improved when reducing the e-PASS threshold to a subclinical result. Test-retest reliability ranged from moderate (eg, specific phobia: κ=.54) to substantial (eg, bulimia nervosa: κ=.87). Conclusions The e-PASS produces reliable diagnostic results and performs generally well in excluding mental disorders, although at the expense of sensitivity. For screening purposes, the e-PASS subclinical result generally appears better than a clinical result as a diagnostic indicator. Further development and evaluation is needed to support the use of online diagnostic assessment programs for mental disorders. Trial Registration Australian and New Zealand Clinical Trials Registry ACTRN121611000704998; http://www.anzctr.org.au/trial_view.aspx?ID=336143 (Archived by WebCite at http://www.webcitation.org/618r3wvOG). PMID:26392066
A USEPA-sponsored field demonstration program was conducted to gather technically reliable cost and performance information on the electro-scan (FELL -41) pipeline condition assessment technology. Electro-scan technology can be used to estimate the magnitude and location of pote...
Assessing Student Learning: A Collection of Evaluation Tools
ERIC Educational Resources Information Center
Gottfried, Gail M.; Johnson, Kathy E.; Vosmik, Jordan R.
2009-01-01
Whereas grading systems based on tacit knowledge may be the norm in practice, the recent trend toward educational accountability--from granting organizations, accreditation boards, journals on the teaching of psychology, and even tenure/promotion committees--suggests a real need for reliable, validated assessment measures that can be used to…
ERIC Educational Resources Information Center
Sandilos, Lia E.
2012-01-01
The purpose of the current study was to evaluate the structural validity and stability of scores on a measure of global classroom quality, the Classroom Assessment Scoring System, Kindergarten-Third Grade (CLASS K-3; Pianta, La Paro, & Hamre, 2008). Using data from a sample of 417 kindergarten classrooms in the rural Southern and Mid-Atlantic…
Reliability and Validity of the Footprint Assessment Method Using Photoshop CS5 Software.
Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam
2015-05-01
Several sophisticated methods of footprint analysis currently exist. However, it is sometimes useful to apply standard measurement methods of recognized evidence with an easy and quick application. We sought to assess the reliability and validity of a new method of footprint assessment in a healthy population using Photoshop CS5 software (Adobe Systems Inc, San Jose, California). Forty-two footprints, corresponding to 21 healthy individuals (11 men with a mean ± SD age of 20.45 ± 2.16 years and 10 women with a mean ± SD age of 20.00 ± 1.70 years) were analyzed. Footprints were recorded in static bipedal standing position using optical podography and digital photography. Three trials for each participant were performed. The Hernández-Corvo, Chippaux-Smirak, and Staheli indices and the Clarke angle were calculated by manual method and by computerized method using Photoshop CS5 software. Test-retest was used to determine reliability. Validity was obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed high values (ICC, 0.98-0.99). Moreover, the validity test clearly showed no difference between techniques (ICC, 0.99-1). The reliability and validity of a method to measure, assess, and record the podometric indices using Photoshop CS5 software has been demonstrated. This provides a quick and accurate tool useful for the digital recording of morphostatic foot study parameters and their control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mays, S.E.; Poloski, J.P.; Sullivan, W.H.
1982-07-01
This report describes a risk study of the Browns Ferry, Unit 1, nuclear plant. The study is one of four such studies sponsored by the NRC Office of Research, Division of Risk Assessment, as part of its Interim Reliability Evaluation Program (IREP), Phase II. This report is contained in four volumes: a main report and three appendixes. Appendix B provides a description of Browns Ferry, Unit 1, plant systems and the failure evaluation of those systems as they apply to accidents at Browns Ferry. Information is presented concerning front-line system fault analysis; support system fault analysis; human error models andmore » probabilities; and generic control circuit analyses.« less
Aziz, M M; Galal, M A A; Elzohri, M H; El-Nouby, F; Leong, K P
2018-04-01
Systemic lupus erythematosus (SLE) is a chronic autoimmune disease which affects all aspects of quality of life (QoL) of the patients. Comprehensive patient assessment should include QoL measures in addition to the objective clinical measures of the disease. There is no specific Arabic instrument for assessment of QoL of SLE patients. The objective of this study was to translate and cross culturally adapt the SLEQOL questionnaire into Arabic and test its reliability and validity. The SLEQOL questionnaire was translated into Arabic based on the Guidelines for Translation and Cross-cultural Adaptation into other languages. Reliability was assessed by interviewing patients three times: two interviews on the same day by different interviewers and the third interview 14 days later by one of the first interviewers. Validity was assessed by correlating SLEQOL scores of 91 patients with 36-item Short Form Health Survey (SF-36) scores and clinical parameters of the patients. We found that the Arabic version of SLEQOL has a Cronbach's alpha of 0.936, interobserver and intraobserver correlation coefficients of 0.809 and 0.886 respectively. Strong correlations were also found between SLEQOL scores and SF-36 Physical and Mental Component summaries. In conclusion, the Arabic version of SLEQOL is a reliable and valid instrument for measuring QoL of Egyptian SLE patients.
Probabilistic assessment of dynamic system performance. Part 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belhadj, Mohamed
1993-01-01
Accurate prediction of dynamic system failure behavior can be important for the reliability and risk analyses of nuclear power plants, as well as for their backfitting to satisfy given constraints on overall system reliability, or optimization of system performance. Global analysis of dynamic systems through investigating the variations in the structure of the attractors of the system and the domains of attraction of these attractors as a function of the system parameters is also important for nuclear technology in order to understand the fault-tolerance as well as the safety margins of the system under consideration and to insure a safemore » operation of nuclear reactors. Such a global analysis would be particularly relevant to future reactors with inherent or passive safety features that are expected to rely on natural phenomena rather than active components to achieve and maintain safe shutdown. Conventionally, failure and global analysis of dynamic systems necessitate the utilization of different methodologies which have computational limitations on the system size that can be handled. Using a Chapman-Kolmogorov interpretation of system dynamics, a theoretical basis is developed that unifies these methodologies as special cases and which can be used for a comprehensive safety and reliability analysis of dynamic systems.« less
Issues in NASA Program and Project Management: Focus on Project Planning and Scheduling
NASA Technical Reports Server (NTRS)
Hoffman, Edward J. (Editor); Lawbaugh, William M. (Editor)
1997-01-01
Topics addressed include: Planning and scheduling training for working project teams at NASA, overview of project planning and scheduling workshops, project planning at NASA, new approaches to systems engineering, software reliability assessment, and software reuse in wind tunnel control systems.
Grooten, Wilhelmus Johannes Andreas; Sandberg, Lisa; Ressman, John; Diamantoglou, Nicolas; Johansson, Elin; Rasmussen-Barr, Eva
2018-01-08
Clinical examinations are subjective and often show a low validity and reliability. Objective and highly reliable quantitative assessments are available in laboratory settings using 3D motion analysis, but these systems are too expensive to use for simple clinical examinations. Qinematic™ is an interactive movement analyses system based on the Kinect camera and is an easy-to-use clinical measurement system for assessing posture, balance and side-bending. The aim of the study was to test the test-retest the reliability and construct validity of Qinematic™ in a healthy population, and to calculate the minimal clinical differences for the variables of interest. A further aim was to identify the discriminative validity of Qinematic™ in people with low-back pain (LBP). We performed a test-retest reliability study (n = 37) with around 1 week between the occasions, a construct validity study (n = 30) in which Qinematic™ was tested against a 3D motion capture system, and a discriminative validity study, in which a group of people with LBP (n = 20) was compared to healthy controls (n = 17). We tested a large range of psychometric properties of 18 variables in three sections: posture (head and pelvic position, weight distribution), balance (sway area and velocity in single- and double-leg stance), and side-bending. The majority of the variables in the posture and balance sections, showed poor/fair reliability (ICC < 0.4) and poor/fair validity (Spearman <0.4), with significant differences between occasions, between Qinematic™ and the 3D-motion capture system. In the clinical study, Qinematic™ did not differ between people with LPB and healthy for these variables. For one variable, side-bending to the left, there was excellent reliability (ICC =0.898), excellent validity (r = 0.943), and Qinematic™ could differentiate between LPB and healthy individuals (p = 0.012). This paper shows that a novel software program (Qinematic™) based on the Kinect camera for measuring balance, posture and side-bending has poor psychometric properties, indicating that the variables on balance and posture should not be used for monitoring individual changes over time or in research. Future research on the dynamic tasks of Qinematic™ is warranted.
NASA Astrophysics Data System (ADS)
Akhmetova, I. G.; Chichirova, N. D.
2016-12-01
Heat supply is the most energy-consuming sector of the economy. Approximately 30% of all used primary fuel-and-energy resources is spent on municipal heat-supply needs. One of the key indicators of activity of heat-supply organizations is the reliability of an energy facility. The reliability index of a heat supply organization is of interest to potential investors for assessing risks when investing in projects. The reliability indices established by the federal legislation are actually reduced to a single numerical factor, which depends on the number of heat-supply outages in connection with disturbances in operation of heat networks and the volume of their resource recovery in the calculation year. This factor is rather subjective and may change in a wide range during several years. A technique is proposed for evaluating the reliability of heat-supply organizations with the use of the simple additive weighting (SAW) method. The technique for integrated-index determination satisfies the following conditions: the reliability level of the evaluated heat-supply system is represented maximum fully and objectively; the information used for the reliability-index evaluation is easily available (is located on the Internet in accordance with demands of data-disclosure standards). For reliability estimation of heat-supply organizations, the following indicators were selected: the wear of equipment of thermal energy sources, the wear of heat networks, the number of outages of supply of thermal energy (heat carrier due to technological disturbances on heat networks per 1 km of heat networks), the number of outages of supply of thermal energy (heat carrier due to technologic disturbances on thermal energy sources per 1 Gcal/h of installed power), the share of expenditures in the cost of thermal energy aimed at recovery of the resource (renewal of fixed assets), coefficient of renewal of fixed assets, and a coefficient of fixed asset retirement. A versatile program is developed and the analysis of heat-supply organizations is performed by the example of the Republic of Tatarstan. The assessment system is based on construction of comparative ratings of heat-supply organizations. A rating is the assessment of reliability of the organization, is characterized by a numerical value, and makes it possible to compare organizations engaged in the same kind of activity between each other.
Venkataraman, Vinay; Turaga, Pavan; Baran, Michael; Lehrer, Nicole; Du, Tingfang; Cheng, Long; Rikakis, Thanassis; Wolf, Steven L.
2016-01-01
In this paper, we propose a general framework for tuning component-level kinematic features using therapists’ overall impressions of movement quality, in the context of a Home-based Adaptive Mixed Reality Rehabilitation (HAMRR) system. We propose a linear combination of non-linear kinematic features to model wrist movement, and propose an approach to learn feature thresholds and weights using high-level labels of overall movement quality provided by a therapist. The kinematic features are chosen such that they correlate with the quality of wrist movements to clinical assessment scores. Further, the proposed features are designed to be reliably extracted from an inexpensive and portable motion capture system using a single reflective marker on the wrist. Using a dataset collected from ten stroke survivors, we demonstrate that the framework can be reliably used for movement quality assessment in HAMRR systems. The system is currently being deployed for large-scale evaluations, and will represent an increasingly important application area of motion capture and activity analysis. PMID:25438331
Large wind energy converter: Growian 3 MW
NASA Technical Reports Server (NTRS)
Koerber, F.; Thiele, H. A.
1979-01-01
The main features of the Growian wind energy converter are presented. Energy yield, environmental impact, and construction of the energy converter are discussed. Reliability of the windpowered system is assessed.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-28
... Subcommittee On Digital I&C Systems The ACRS Subcommittee on Digital Instrumentation and Control (DI&C) Systems... the area of Digital Instrumentation and Control (DI&C) Probabilistic Risk Assessment (PRA). Topics... software reliability methods (QSRMs), NUREG/CR--6997, ``Modeling a Digital Feedwater Control System Using...
ERIC Educational Resources Information Center
Stirling, Keith
2000-01-01
Describes a session on information retrieval systems that planned to discuss relevance measures with Web-based information retrieval; retrieval system performance and evaluation; probabilistic independence of index terms; vector-based models; metalanguages and digital objects; how users assess the reliability, timeliness and bias of information;…
Erkes, Jérôme; Camp, Cameron J; Raffard, Stéphane; Gély-Nargeot And, Marie-Christine; Bayard, Sophie
2017-01-01
This study evaluated the validity and reliability of the Montessori Assessment System. The Montessori Assessment System assesses preserved abilities in persons with moderate to severe dementia. In this respect, this instrument provides crucial information for the development of effective person-centered care plans. A total of 196 persons with a diagnosis of dementia in the moderate to severe stages of dementia were recruited in 10 long-term care facilities in France. All participants completed the Montessori Assessment System, the Clinical Dementia Rating Scale and/or the Mini Mental State Examination and the Severe Impairment Battery-short form. The internal consistency and temporal stability of the Montessori Assessment System were high. Additionally, good construct and divergent validity were demonstrated. Factor analysis showed a one-factor structure. The Montessori Assessment System demonstrated satisfactory psychometric properties while being a useful instrument to assess capabilities in persons with advanced stages of dementia and hence to develop person-centered plans of care.
Validity and Reliability Testing of an e-learning Questionnaire for Chemistry Instruction
NASA Astrophysics Data System (ADS)
Guspatni, G.; Kurniawati, Y.
2018-04-01
The aim of this paper is to examine validity and reliability of a questionnaire used to evaluate e-learning implementation in chemistry instruction. 48 questionnaires were filled in by students who had studied chemistry through e-learning system. The questionnaire consisted of 20 indicators evaluating students’ perception on using e-learning. Parametric testing was done as data were assumed to follow normal distribution. Item validity of the questionnaire was examined through item-total correlation using Pearson’s formula while its reliability was assessed with Cronbach’s alpha formula. Moreover, convergent validity was assessed to see whether indicators building a factor had theoretically the same underlying construct. The result of validity testing revealed 19 valid indicators while the result of reliability testing revealed Cronbach’s alpha value of .886. The result of factor analysis showed that questionnaire consisted of five factors, and each of them had indicators building the same construct. This article shows the importance of factor analysis to get a construct valid questionnaire before it is used as research instrument.
NASA Technical Reports Server (NTRS)
Lee, Alice T.; Gunn, Todd; Pham, Tuan; Ricaldi, Ron
1994-01-01
This handbook documents the three software analysis processes the Space Station Software Analysis team uses to assess space station software, including their backgrounds, theories, tools, and analysis procedures. Potential applications of these analysis results are also presented. The first section describes how software complexity analysis provides quantitative information on code, such as code structure and risk areas, throughout the software life cycle. Software complexity analysis allows an analyst to understand the software structure, identify critical software components, assess risk areas within a software system, identify testing deficiencies, and recommend program improvements. Performing this type of analysis during the early design phases of software development can positively affect the process, and may prevent later, much larger, difficulties. The second section describes how software reliability estimation and prediction analysis, or software reliability, provides a quantitative means to measure the probability of failure-free operation of a computer program, and describes the two tools used by JSC to determine failure rates and design tradeoffs between reliability, costs, performance, and schedule.
The Aviation Paradox: Why We Can 'Know' Jetliners But Not Reactors.
Downer, John
2017-01-01
Publics and policymakers increasingly have to contend with the risks of complex, safety-critical technologies, such as airframes and reactors. As such, 'technological risk' has become an important object of modern governance, with state regulators as core agents, and 'reliability assessment' as the most essential metric. The Science and Technology Studies (STS) literature casts doubt on whether or not we should place our faith in these assessments because predictively calculating the ultra-high reliability required of such systems poses seemingly insurmountable epistemological problems. This paper argues that these misgivings are warranted in the nuclear sphere, despite evidence from the aviation sphere suggesting that such calculations can be accurate. It explains why regulatory calculations that predict the reliability of new airframes cannot work in principle, and then it explains why those calculations work in practice. It then builds on this explanation to argue that the means by which engineers manage reliability in aviation is highly domain-specific, and to suggest how a more nuanced understanding of jetliners could inform debates about nuclear energy.
Sternberg, Scot B; Co, John Patrick T; Homer, Charles J
2011-01-01
To identify, assess, and make recommendations for inclusion of measures that assess the domain of "most integrated health care setting," with a specific focus on measures of the medical home, one particular mechanism for integrating care, to identify gaps in measurement; and to make recommendations for new measure development. We developed a conceptual framework for care integration and reviewed literature on measures assessing the presence and quality of the medical home to determine their validity, reliability, and feasibility as a proxy for care integration. We identified 2 broad approaches to assessing the extent to which patients receive care that fulfills the aims of the medical home: 1) organizational assessment of practice systems and processes thought associated with achieving these desired aims (viz, the National Committee for Quality Assurance Physician Practice Connections-Patient Centered Medical Home measure and the Medical Home Index, and 2) direct assessment by patients/families of their experience of care in targeted dimensions. Based on concerns about the absence of reliability data and the feasibility of applying the practice audit/self-assessment approach on a population level for the purpose of state reporting, as well as the limited data linking performance on the specific measures with important child outcomes, we did not recommend any of the measures of organizational assessments of practice systems for inclusion in the core set as an indicator of care integration. In contrast, measures of the medical home based on items from the National Survey of Child Health on a population level of or the Consumer Assessment of Healthcare Providers and Systems for practice- and state-level assessment are more feasible, have known reliability and performance characteristics, and more closely reflect the aims of the medical home, including care integration. Measures of health care integration as captured by the experience of care in a medical home can best be assessed for state-level performance through patient/family experience surveys. Better measures of care integration, care coordination, and integration of mental, developmental, and physical health into a comprehensive care system are high-priority topics for measure development. Copyright © 2011 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Comprehensive clinical assessment in community setting: applicability of the MDS-HC.
Morris, J N; Fries, B E; Steel, K; Ikegami, N; Bernabei, R; Carpenter, G I; Gilgen, R; Hirdes, J P; Topinková, E
1997-08-01
To describe the results of an international trial of the home care version of the MDS assessment and problem identification system (the MDS-HC), including reliability estimates, a comparison of MDS-HC reliabilities with reliabilities of the same items in the MDS 2.0 nursing home assessment instrument, and an examination of the types of problems found in home care clients using the MDS-HC. Independent, dual assessment of clients of home-care agencies by trained clinicians using a draft of the MDS-HC, with additional descriptive data regarding problem profiles for home care clients. Reliability data from dual assessments of 241 randomly selected clients of home care agencies in five countries, all of whom volunteered to test the MDS-HC. Also included are an expanded sample of 780 home care assessments from these countries and 187 dually assessed residents from 21 nursing homes in the United States. The array of MDS-HC assessment items included measures in the following areas: personal items, cognitive patterns, communication/hearing, vision, mood and behavior, social functioning, informal support services, physical functioning, continence, disease diagnoses health conditions and preventive health measures, nutrition/hydration, dental status, skin condition, environmental assessment, service utilization, and medications. Forty-seven percent of the functional, health status, social environment, and service items in the MDS-HC were taken from the MDS 2.0 for nursing homes. For this item set, it is estimated that the average weighted Kappa is .74 for the MDS-HC and .75 for the MDS 2.0. Similarly, high reliability values were found for items newly introduced in the MDS-HC (weighted Kappa = .70). Descriptive findings also characterize the problems of home care clients, with subanalyses within cognitive performance levels. Findings indicate that the core set of items in the MDS 2.0 work equally well in community and nursing home settings. New items are highly reliable. In tandem, these instruments can be used within the international community, assisting and planning care for older adults within a broad spectrum of service settings, including nursing homes and home care programs. With this community-based, second-generation problem and care plan-driven assessment instrument, disability assessment can be performed consistently across the world.
2011-01-01
Background Although measures of knowledge translation and exchange (KTE) effectiveness based on the theory of planned behavior (TPB) have been used among patients and providers, no measure has been developed for use among health system policymakers and stakeholders. A tool that measures the intention to use research evidence in policymaking could assist researchers in evaluating the effectiveness of KTE strategies that aim to support evidence-informed health system decision-making. Therefore, we developed a 15-item tool to measure four TPB constructs (intention, attitude, subjective norm and perceived control) and assessed its face validity through key informant interviews. Methods We carried out a reliability study to assess the tool's internal consistency and test-retest reliability. Our study sample consisted of 62 policymakers and stakeholders that participated in deliberative dialogues. We assessed internal consistency using Cronbach's alpha and generalizability (G) coefficients, and we assessed test-retest reliability by calculating Pearson correlation coefficients (r) and G coefficients for each construct and the tool overall. Results The internal consistency of items within each construct was good with alpha ranging from 0.68 to alpha = 0.89. G-coefficients were lower for a single administration (G = 0.34 to G = 0.73) than for the average of two administrations (G = 0.79 to G = 0.89). Test-retest reliability coefficients for the constructs ranged from r = 0.26 to r = 0.77 and from G = 0.31 to G = 0.62 for a single administration, and from G = 0.47 to G = 0.86 for the average of two administrations. Test-retest reliability of the tool using G theory was moderate (G = 0.5) when we generalized across a single observation, but became strong (G = 0.9) when we averaged across both administrations. Conclusion This study provides preliminary evidence for the reliability of a tool that can be used to measure TPB constructs in relation to research use in policymaking. Our findings suggest that the tool should be administered on more than one occasion when the intervention promotes an initial 'spike' in enthusiasm for using research evidence (as it seemed to do in this case with deliberative dialogues). The findings from this study will be used to modify the tool and inform further psychometric testing following different KTE interventions. PMID:21702956
Restoring Faith in the bulk-power system: an early assessment of mandatory reliability standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
McAllister, Levi; Dawson, Kelly L.
2010-03-15
The driving force underlying creation of mandatory reliability standards was the prevention of widespread outages, such as those that occurred in 1965, 1977 and 2003. So far, no similar outage has occurred when an entity is in full compliance with the standards, and NERC and FERC have demonstrated that they will actively enforce compliance while aggressively pursuing entities alleged to be non-compliant. (author)
Constructing the "Best" Reliability Data for the Job
NASA Technical Reports Server (NTRS)
DeMott, D. L.; Kleinhammer, R. K.
2014-01-01
Modern business and technical decisions are based on the results of analyses. When considering assessments using "reliability data", the concern is how long a system will continue to operate as designed. Generally, the results are only as good as the data used. Ideally, a large set of pass/fail tests or observations to estimate the probability of failure of the item under test would produce the best data. However, this is a costly endeavor if used for every analysis and design. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, we attempt to develop the "best" or composite analog data to support our assessments. One method used incorporates processes for reviewing existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. Data that is more representative of reality and more project specific would provide more accurate analysis, and hopefully a better final decision.
Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Rey-Abella, Ferran; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam
2016-05-01
People with Down syndrome present skeletal abnormalities in their feet that can be analyzed by commonly used gold standard indices (the Hernández-Corvo index, the Chippaux-Smirak index, the Staheli arch index, and the Clarke angle) based on footprint measurements. The use of Photoshop CS5 software (Adobe Systems Software Ireland Ltd, Dublin, Ireland) to measure footprints has been validated in the general population. The present study aimed to assess the reliability and validity of this footprint assessment technique in the population with Down syndrome. Using optical podography and photography, 44 footprints from 22 patients with Down syndrome (11 men [mean ± SD age, 23.82 ± 3.12 years] and 11 women [mean ± SD age, 24.82 ± 6.81 years]) were recorded in a static bipedal standing position. A blinded observer performed the measurements using a validated manual method three times during the 4-month study, with 2 months between measurements. Test-retest was used to check the reliability of the Photoshop CS5 software measurements. Validity and reliability were obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed very good values for the Photoshop CS5 method (ICC, 0.982-0.995). Validity testing also found no differences between the techniques (ICC, 0.988-0.999). The Photoshop CS5 software method is reliable and valid for the study of footprints in young people with Down syndrome.
Constructing the Best Reliability Data for the Job
NASA Technical Reports Server (NTRS)
Kleinhammer, R. K.; Kahn, J. C.
2014-01-01
Modern business and technical decisions are based on the results of analyses. When considering assessments using "reliability data", the concern is how long a system will continue to operate as designed. Generally, the results are only as good as the data used. Ideally, a large set of pass/fail tests or observations to estimate the probability of failure of the item under test would produce the best data. However, this is a costly endeavor if used for every analysis and design. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, we attempt to develop the "best" or composite analog data to support our assessments. One method used incorporates processes for reviewing existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. Data that is more representative of reality and more project specific would provide more accurate analysis, and hopefully a better final decision.
Inspection planning development: An evolutionary approach using reliability engineering as a tool
NASA Technical Reports Server (NTRS)
Graf, David A.; Huang, Zhaofeng
1994-01-01
This paper proposes an evolutionary approach for inspection planning which introduces various reliability engineering tools into the process and assess system trade-offs among reliability, engineering requirement, manufacturing capability and inspection cost to establish an optimal inspection plan. The examples presented in the paper illustrate some advantages and benefits of the new approach. Through the analysis, reliability and engineering impacts due to manufacturing process capability and inspection uncertainty are clearly understood; the most cost effective and efficient inspection plan can be established and associated risks are well controlled; some inspection reductions and relaxations are well justified; and design feedbacks and changes may be initiated from the analysis conclusion to further enhance reliability and reduce cost. The approach is particularly promising as global competitions and customer quality improvement expectations are rapidly increasing.
Weech-Maldonado, Robert; Dreachslin, Janice L; Brown, Julie; Pradhan, Rohit; Rubin, Kelly L; Schiller, Cameron; Hays, Ron D
2012-01-01
The U.S. national standards for culturally and linguistically appropriate services (CLAS) in health care provide guidelines on policies and practices aimed at developing culturally competent systems of care. The Cultural Competency Assessment Tool for Hospitals (CCATH) was developed as an organizational tool to assess adherence to the CLAS standards. First, we describe the development of the CCATH and estimate the reliability and validity of the CCATH measures. Second, we discuss the managerial implications of the CCATH as an organizational tool to assess cultural competency. We pilot tested an initial draft of the CCATH, revised it based on a focus group and cognitive interviews, and then administered it in a field test with a sample of California hospitals. The reliability and validity of the CCATH were evaluated using factor analysis, analysis of variance, and Cronbach's alphas. Exploratory and confirmatory factor analyses identified 12 CCATH composites: leadership and strategic planning, data collection on inpatient population, data collection on service area, performance management systems and quality improvement, human resources practices, diversity training, community representation, availability of interpreter services, interpreter services policies, quality of interpreter services, translation of written materials, and clinical cultural competency practices. All the CCATH scales had internal consistency reliability of .65 or above, and the reliability was .70 or above for 9 of the 12 scales. Analysis of variance results showed that not-for-profit hospitals have higher CCATH scores than for-profit hospitals in five CCATH scales and higher CCATH scores than government hospitals in two CCATH scales. The CCATH showed adequate psychometric properties. Managers and policy makers can use the CCATH as a tool to evaluate hospital performance in cultural competency and identify and target improvements in hospital policies and practices that undergird the provision of CLAS.
Ruff, Jessica; Wang, Tiffany L; Quatman-Yates, Catherine C; Phieffer, Laura S; Quatman, Carmen E
2015-02-01
Commercially available gaming systems (CAGS) such as the Wii Balance Board (WBB) and Microsoft Xbox with Kinect (Xbox Kinect) are increasingly used as balance training and rehabilitation tools. The purpose of this review was to answer the question, "Are commercially available gaming systems valid and reliable instruments for use as clinical diagnostic and functional assessment tools in orthopaedic settings?" and provide a summary of relevant studies, identify their strengths and weaknesses, and generate conclusions regarding general validity/reliability of WBB and Xbox Kinect in orthopaedics. A systematic search was performed using MEDLINE (1996-2013) and Scopus (1996-2013). Inclusion criteria were minimum of 5 subjects, full manuscript provided in English or translated, and studies incorporating investigation of CAG measurement properties. Exclusion criteria included reviews, systematic reviews, summary/clinical commentaries, or case studies; conference proceedings/presentations; cadaveric studies; studies of non-reversible, non-orthopaedic-related musculoskeletal disease; non-human trials; and therapeutic studies not reporting comparative evaluation to already established functional assessment criteria. All studies meeting inclusion and exclusion criteria were appraised for quality by two independent reviewers. Evidence levels (I-V) were assigned to each study based on established methodological criteria. 3 Level II, 7 level III, and 1 Level IV studies met inclusion criteria and provided information related to the use of the WBB and Xbox Kinect as clinical assessment tools in the field of orthopaedics. Studies have used the WBB in a variety of clinical applications, including the measurement of center of pressure (COP), measurement of medial-to-lateral (M/L) or anterior-to-posterior (A/P) symmetry, assessment anatomic landmark positioning, and assessment of fall risk. However, no uniform protocols or outcomes were used to evaluate the quality of the WBB as a clinical assessment tool; therefore a wide range of sensitivities, specificities, accuracies, and validities were reported. Currently it is not possible to make a universal generalization about the clinical utility of CAGS in the field of orthopaedics. However, there is evidence to support using the WBB and the Xbox Kinect as tools to obtain reliable and valid COP measurements. The Wii Fit Game may specifically provide reliable and valid measurements for predicting fall risk. Copyright © 2014 Elsevier Ltd. All rights reserved.
WaferOptics® mass volume production and reliability
NASA Astrophysics Data System (ADS)
Wolterink, E.; Demeyer, K.
2010-05-01
The Anteryon WaferOptics® Technology platform contains imaging optics designs, materials, metrologies and combined with wafer level based Semicon & MEMS production methods. WaferOptics® first required complete new system engineering. This system closes the loop between application requirement specifications, Anteryon product specification, Monte Carlo Analysis, process windows, process controls and supply reject criteria. Regarding the Anteryon product Integrated Lens Stack (ILS), new design rules, test methods and control systems were assessed, implemented, validated and customer released for mass production. This includes novel reflowable materials, mastering process, replication, bonding, dicing, assembly, metrology, reliability programs and quality assurance systems. Many of Design of Experiments were performed to assess correlations between optical performance parameters and machine settings of all process steps. Lens metrologies such as FFL, BFL, and MTF were adapted for wafer level production and wafer mapping was introduced for yield management. Test methods for screening and validating suitable optical materials were designed. Critical failure modes such as delamination and popcorning were assessed and modeled with FEM. Anteryon successfully managed to integrate the different technologies starting from single prototypes to high yield mass volume production These parallel efforts resulted in a steep yield increase from 30% to over 90% in a 8 months period.
System Risk Assessment and Allocation in Conceptual Design
NASA Technical Reports Server (NTRS)
Mahadevan, Sankaran; Smith, Natasha L.; Zang, Thomas A. (Technical Monitor)
2003-01-01
As aerospace systems continue to evolve in addressing newer challenges in air and space transportation, there exists a heightened priority for significant improvement in system performance, cost effectiveness, reliability, and safety. Tools, which synthesize multidisciplinary integration, probabilistic analysis, and optimization, are needed to facilitate design decisions allowing trade-offs between cost and reliability. This study investigates tools for probabilistic analysis and probabilistic optimization in the multidisciplinary design of aerospace systems. A probabilistic optimization methodology is demonstrated for the low-fidelity design of a reusable launch vehicle at two levels, a global geometry design and a local tank design. Probabilistic analysis is performed on a high fidelity analysis of a Navy missile system. Furthermore, decoupling strategies are introduced to reduce the computational effort required for multidisciplinary systems with feedback coupling.
DiClemente, Carlo C; Crouch, Taylor Berens; Norwood, Amber E Q; Delahanty, Janine; Welsh, Christopher
2015-03-01
Screening, brief intervention, and referral to treatment (SBIRT) has become an empirically supported and widely implemented approach in primary and specialty care for addressing substance misuse. Accordingly, training of providers in SBIRT has increased exponentially in recent years. However, the quality and fidelity of training programs and subsequent interventions are largely unknown because of the lack of SBIRT-specific evaluation tools. The purpose of this study was to create a coding scale to assess quality and fidelity of SBIRT interactions addressing alcohol, tobacco, illicit drugs, and prescription medication misuse. The scale was developed to evaluate performance in an SBIRT residency training program. Scale development was based on training protocol and competencies with consultation from Motivational Interviewing coding experts. Trained medical residents practiced SBIRT with standardized patients during 10- to 15-min videotaped interactions. This study included 25 tapes from the Family Medicine program coded by 3 unique coder pairs with varying levels of coding experience. Interrater reliability was assessed for overall scale components and individual items via intraclass correlation coefficients. Coder pair-specific reliability was also assessed. Interrater reliability was excellent overall for the scale components (>.85) and nearly all items. Reliability was higher for more experienced coders, though still adequate for the trained coder pair. Descriptive data demonstrated a broad range of adherence and skills. Subscale correlations supported concurrent and discriminant validity. Data provide evidence that the MD3 SBIRT Coding Scale is a psychometrically reliable coding system for evaluating SBIRT interactions and can be used to evaluate implementation skills for fidelity, training, assessment, and research. Recommendations for refinement and further testing of the measure are discussed. (PsycINFO Database Record (c) 2015 APA, all rights reserved).
Undergraduate nursing students' perspectives on clinical assessment at transition to practice.
Wu, Xi Vivien; Wang, Wenru; Pua, Lay Hoon; Heng, Doreen Gek Noi; Enskär, Karin
2015-01-01
Assessment of clinical competence requires explicitly defined standards meeting the national standards of the nursing profession. This is a complex process because of the diverse nature of nursing practice. To explore the perceptions of final-year undergraduate nursing students regarding clinical assessment at transition to practice. An exploratory qualitative approach was adopted. Twenty-four students participated in three focus group discussions. Thematic analysis was conducted. Five themes emerged: the need for a valid and reliable clinical assessment tool, the need for a flexible style of reflection and specific feedback, the dynamic clinical learning environment, students' efforts in learning and assessment, and the unclear support system for preceptors. Workload, time, resource availability, adequate preparation of preceptors, and the provision of valid and reliable clinical assessment tools were deemed to influence the quality of students' clinical learning and assessment. Nursing leadership in hospitals and educational institutions has a joint responsibility in shaping the clinical learning environment and providing clinical assessments for the students.
Automated reliability assessment for spectroscopic redshift measurements
NASA Astrophysics Data System (ADS)
Jamal, S.; Le Brun, V.; Le Fèvre, O.; Vibert, D.; Schmitt, A.; Surace, C.; Copin, Y.; Garilli, B.; Moresco, M.; Pozzetti, L.
2018-03-01
Context. Future large-scale surveys, such as the ESA Euclid mission, will produce a large set of galaxy redshifts (≥106) that will require fully automated data-processing pipelines to analyze the data, extract crucial information and ensure that all requirements are met. A fundamental element in these pipelines is to associate to each galaxy redshift measurement a quality, or reliability, estimate. Aim. In this work, we introduce a new approach to automate the spectroscopic redshift reliability assessment based on machine learning (ML) and characteristics of the redshift probability density function. Methods: We propose to rephrase the spectroscopic redshift estimation into a Bayesian framework, in order to incorporate all sources of information and uncertainties related to the redshift estimation process and produce a redshift posterior probability density function (PDF). To automate the assessment of a reliability flag, we exploit key features in the redshift posterior PDF and machine learning algorithms. Results: As a working example, public data from the VIMOS VLT Deep Survey is exploited to present and test this new methodology. We first tried to reproduce the existing reliability flags using supervised classification in order to describe different types of redshift PDFs, but due to the subjective definition of these flags (classification accuracy 58%), we soon opted for a new homogeneous partitioning of the data into distinct clusters via unsupervised classification. After assessing the accuracy of the new clusters via resubstitution and test predictions (classification accuracy 98%), we projected unlabeled data from preliminary mock simulations for the Euclid space mission into this mapping to predict their redshift reliability labels. Conclusions: Through the development of a methodology in which a system can build its own experience to assess the quality of a parameter, we are able to set a preliminary basis of an automated reliability assessment for spectroscopic redshift measurements. This newly-defined method is very promising for next-generation large spectroscopic surveys from the ground and in space, such as Euclid and WFIRST. A table of the reclassified VVDS redshifts and reliability is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/611/A53
Lo, Men-Tzung; Hu, Kun; Liu, Yanhui; Peng, C.-K.; Novak, Vera
2008-01-01
Quantification of nonlinear interactions between two nonstationary signals presents a computational challenge in different research fields, especially for assessments of physiological systems. Traditional approaches that are based on theories of stationary signals cannot resolve nonstationarity-related issues and, thus, cannot reliably assess nonlinear interactions in physiological systems. In this review we discuss a new technique “Multi-Modal Pressure Flow method (MMPF)” that utilizes Hilbert-Huang transformation to quantify dynamic cerebral autoregulation (CA) by studying interaction between nonstationary cerebral blood flow velocity (BFV) and blood pressure (BP). CA is an important mechanism responsible for controlling cerebral blood flow in responses to fluctuations in systemic BP within a few heart-beats. The influence of CA is traditionally assessed from the relationship between the well-pronounced systemic BP and BFV oscillations induced by clinical tests. Reliable noninvasive assessment of dynamic CA, however, remains a challenge in clinical and diagnostic medicine. In this brief review we: 1) present an overview of transfer function analysis (TFA) that is traditionally used to quantify CA; 2) describe the a MMPF method and its modifications; 3) introduce a newly developed automatic algorithm and engineering aspects of the improved MMPF method; and 4) review clinical applications of MMPF and its sensitivity for detection of CA abnormalities in clinical studies. The MMPF analysis decomposes complex nonstationary BP and BFV signals into multiple empirical modes adaptively so that the fluctuations caused by a specific physiologic process can be represented in a corresponding empirical mode. Using this technique, we recently showed that dynamic CA can be characterized by specific phase delays between the decomposed BP and BFV oscillations, and that the phase shifts are significantly reduced in hypertensive, diabetics and stroke subjects with impaired CA. In addition, the new technique enables reliable assessment of CA using both data collected during clinical test and spontaneous BP/BFV fluctuations during baseline resting conditions. PMID:18725996
Object-oriented fault tree evaluation program for quantitative analyses
NASA Technical Reports Server (NTRS)
Patterson-Hine, F. A.; Koen, B. V.
1988-01-01
Object-oriented programming can be combined with fault free techniques to give a significantly improved environment for evaluating the safety and reliability of large complex systems for space missions. Deep knowledge about system components and interactions, available from reliability studies and other sources, can be described using objects that make up a knowledge base. This knowledge base can be interrogated throughout the design process, during system testing, and during operation, and can be easily modified to reflect design changes in order to maintain a consistent information source. An object-oriented environment for reliability assessment has been developed on a Texas Instrument (TI) Explorer LISP workstation. The program, which directly evaluates system fault trees, utilizes the object-oriented extension to LISP called Flavors that is available on the Explorer. The object representation of a fault tree facilitates the storage and retrieval of information associated with each event in the tree, including tree structural information and intermediate results obtained during the tree reduction process. Reliability data associated with each basic event are stored in the fault tree objects. The object-oriented environment on the Explorer also includes a graphical tree editor which was modified to display and edit the fault trees.
Rickard, Mandy; Easterbrook, Bethany; Kim, Soojin; Farrokhyar, Forough; Stein, Nina; Arora, Steven; Belostotsky, Vladamir; DeMaria, Jorge; Lorenzo, Armando J; Braga, Luis H
2017-02-01
The urinary tract dilation (UTD) classification system was introduced to standardize terminology in the reporting of hydronephrosis (HN), and bridge a gap between pre- and postnatal classification such as the Society for Fetal Urology (SFU) grading system. Herein we compare the intra/inter-rater reliability of both grading systems. SFU (I-IV) and UTD (I-III) grades were independently assigned by 13 raters (9 pediatric urology staff, 2 nephrologists, 2 radiologists), twice, 3 weeks apart, to 50 sagittal postnatal ultrasonographic views of hydronephrotic kidneys. Data regarding ureteral measurements and bladder abnormalities were included to allow proper UTD categorization. Ten images were repeated to assess intra-rater reliability. Krippendorff's alpha coefficient was used to measure overall and by grade intra/inter-rater reliability. Reliability between specialties and training levels were also analyzed. Overall inter-rater reliability was slightly higher for SFU (α = 0.842, 95% CI 0.812-0.879, in session 1; and α = 0.808, 95% CI 0.775-0.839, in session 2) than for UTD (α = 0.774, 95% CI 0.715-0.827, in session 1; and α = 0.679, 95% CI 0.605-0.750, in session 2). Reliability for intermediate grades (SFU II/III and UTD 2) of HN was poor regardless of the system. Reliabilities for SFU and UTD classifications among Urology, Nephrology, and Radiology, as well as between training levels were not significantly different. Despite the introduction of HN grading systems to standardize the interpretation and reporting of renal ultrasound in infants with HN, none have been proven superior in allowing clinicians to distinguish between "moderate" grades. While this study demonstrated high reliability in distinguishing between "mild" (SFU I/II and UTD 1) and "severe" (SFU IV and UTD 3) grades of HN, the overall reliability between specialties was poor. This is in keeping with a previous report of modest inter-rater reliability of the SFU system. This drawback is likely explained by the subjective interpretation required to assign grades, which can be impacted by experience, image quality, and scanning technique. As shown in the figure, which demonstrates SFU II (a) and SFU III (b), as assigned by a radiologist, it is possible to make an argument that either of these images can be classified into both categories that were observed during the grading sessions of this study. Although both systems have acceptable reliability, the SFU grading system showed higher overall intra/inter-rater reliability regardless of rater specialty than the UTD classification. Inter-rater reliability for SFU grades II/III and UTD 2 was low, highlighting the limitations of both classifications in regards to properly segregating moderate HN grades. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Jung, Sung-Hoon; Kwon, Oh-Yun; Jeon, In-Cheol; Hwang, Ui-Jae; Weon, Jong-Hyuck
2018-01-01
The purposes of this study were to determine the intra-rater test-retest reliability of a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion analysis system for measuring the transverse rotation angle of the pelvis during single-leg lifting (SLL) and the criterion validity of the transverse rotation angle of the pelvis measurement using SBMT compared with a 3D motion analysis system (3DMAS). Seventeen healthy volunteers performed SLL with their dominant leg without bending the knee until they reached a target placed 20 cm above the table. This study used a 3DMAS, considered the gold standard, to measure the transverse rotation angle of the pelvis to assess the criterion validity of the SBMT measurement. Intra-rater test-retest reliability was determined using the SBMT and 3DMAS using intra-class correlation coefficient (ICC) [3,1] values. The criterion validity of the SBMT was assessed with ICC [3,1] values. Both the 3DMAS (ICC = 0.77) and SBMT (ICC = 0.83) showed excellent intra-rater test-retest reliability in the measurement of the transverse rotation angle of the pelvis during SLL in a supine position. Moreover, the SBMT showed an excellent correlation with the 3DMAS (ICC = 0.99). Measurement of the transverse rotation angle of the pelvis using the SBMT showed excellent reliability and criterion validity compared with the 3DMAS.
Mohammad Abdulghani, Hamza; G Ponnamperuma, Gominda; Ahmad, Farah; Amin, Zubair
2014-03-01
To evaluate assessment system of the 'Research Methodology Course' using utility criteria (i.e. validity, reliability, acceptability, educational impact, and cost-effectiveness). This study demonstrates comprehensive evaluation of assessment system and suggests a framework for similar courses. Qualitative and quantitative methods used for evaluation of the course assessment components (50 MCQ, 3 Short Answer Questions (SAQ) and research project) using the utility criteria. RESULTS of multiple evaluation methods for all the assessment components were collected and interpreted together to arrive at holistic judgments, rather than judgments based on individual methods or individual assessment. Face validity, evaluated using a self-administered questionnaire (response rate-88.7%) disclosed that the students perceived that there was an imbalance in the contents covered by the assessment. This was confirmed by the assessment blueprint. Construct validity was affected by the low correlation between MCQ and SAQ scores (r=0.326). There was a higher correlation between the project and MCQ (r=0.466)/SAQ (r=0.463) scores. Construct validity was also affected by the presence of recall type of MCQs (70%; 35/50), item construction flaws and non-functioning distractors. High discriminating indices (>0.35) were found in MCQs with moderate difficulty indices (0.3-0.7). Reliability of the MCQs was 0.75 which could be improved up to 0.8 by increasing the number of MCQs to at least 70. A positive educational impact was found in the form of the research project assessment driving students to present/publish their work in conferences/peer reviewed journals. Cost per student to complete the course was US$164.50. The multi-modal evaluation of an assessment system is feasible and provides thorough and diagnostic information. Utility of the assessment system could be further improved by modifying the psychometrically inappropriate assessment items.
Mohammad Abdulghani, Hamza; G. Ponnamperuma, Gominda; Ahmad, Farah; Amin, Zubair
2014-01-01
Objective: To evaluate assessment system of the 'Research Methodology Course' using utility criteria (i.e. validity, reliability, acceptability, educational impact, and cost-effectiveness). This study demonstrates comprehensive evaluation of assessment system and suggests a framework for similar courses. Methods: Qualitative and quantitative methods used for evaluation of the course assessment components (50 MCQ, 3 Short Answer Questions (SAQ) and research project) using the utility criteria. Results of multiple evaluation methods for all the assessment components were collected and interpreted together to arrive at holistic judgments, rather than judgments based on individual methods or individual assessment. Results: Face validity, evaluated using a self-administered questionnaire (response rate-88.7%) disclosed that the students perceived that there was an imbalance in the contents covered by the assessment. This was confirmed by the assessment blueprint. Construct validity was affected by the low correlation between MCQ and SAQ scores (r=0.326). There was a higher correlation between the project and MCQ (r=0.466)/SAQ (r=0.463) scores. Construct validity was also affected by the presence of recall type of MCQs (70%; 35/50), item construction flaws and non-functioning distractors. High discriminating indices (>0.35) were found in MCQs with moderate difficulty indices (0.3-0.7). Reliability of the MCQs was 0.75 which could be improved up to 0.8 by increasing the number of MCQs to at least 70. A positive educational impact was found in the form of the research project assessment driving students to present/publish their work in conferences/peer reviewed journals. Cost per student to complete the course was US$164.50. Conclusions: The multi-modal evaluation of an assessment system is feasible and provides thorough and diagnostic information. Utility of the assessment system could be further improved by modifying the psychometrically inappropriate assessment items. PMID:24772117
ERIC Educational Resources Information Center
Keller, Lisa A.; Clauser, Brian E.; Swanson, David B.
2010-01-01
In recent years, demand for performance assessments has continued to grow. However, performance assessments are notorious for lower reliability, and in particular, low reliability resulting from task specificity. Since reliability analyses typically treat the performance tasks as randomly sampled from an infinite universe of tasks, these estimates…
On the reliability of seasonal climate forecasts.
Weisheimer, A; Palmer, T N
2014-07-06
Seasonal climate forecasts are being used increasingly across a range of application sectors. A recent UK governmental report asked: how good are seasonal forecasts on a scale of 1-5 (where 5 is very good), and how good can we expect them to be in 30 years time? Seasonal forecasts are made from ensembles of integrations of numerical models of climate. We argue that 'goodness' should be assessed first and foremost in terms of the probabilistic reliability of these ensemble-based forecasts; reliable inputs are essential for any forecast-based decision-making. We propose that a '5' should be reserved for systems that are not only reliable overall, but where, in particular, small ensemble spread is a reliable indicator of low ensemble forecast error. We study the reliability of regional temperature and precipitation forecasts of the current operational seasonal forecast system of the European Centre for Medium-Range Weather Forecasts, universally regarded as one of the world-leading operational institutes producing seasonal climate forecasts. A wide range of 'goodness' rankings, depending on region and variable (with summer forecasts of rainfall over Northern Europe performing exceptionally poorly) is found. Finally, we discuss the prospects of reaching '5' across all regions and variables in 30 years time.
Pre-Proposal Assessment of Reliability for Spacecraft Docking with Limited Information
NASA Technical Reports Server (NTRS)
Brall, Aron
2013-01-01
This paper addresses the problem of estimating the reliability of a critical system function as well as its impact on the system reliability when limited information is available. The approach addresses the basic function reliability, and then the impact of multiple attempts to accomplish the function. The dependence of subsequent attempts on prior failure to accomplish the function is also addressed. The autonomous docking of two spacecraft was the specific example that generated the inquiry, and the resultant impact on total reliability generated substantial interest in presenting the results due to the relative insensitivity of overall performance to basic function reliability and moderate degradation given sufficient attempts to try and accomplish the required goal. The application of the methodology allows proper emphasis on the characteristics that can be estimated with some knowledge, and to insulate the integrity of the design from those characteristics that can't be properly estimated with any rational value of uncertainty. The nature of NASA's missions contains a great deal of uncertainty due to the pursuit of new science or operations. This approach can be applied to any function where multiple attempts at success, with or without degradation, are allowed.
Reliability and Validity Assessment of a Linear Position Transducer
Garnacho-Castaño, Manuel V.; López-Lastra, Silvia; Maté-Muñoz, José L.
2015-01-01
The objectives of the study were to determine the validity and reliability of peak velocity (PV), average velocity (AV), peak power (PP) and average power (AP) measurements were made using a linear position transducer. Validity was assessed by comparing measurements simultaneously obtained using the Tendo Weightlifting Analyzer Systemi and T-Force Dynamic Measurement Systemr (Ergotech, Murcia, Spain) during two resistance exercises, bench press (BP) and full back squat (BS), performed by 71 trained male subjects. For the reliability study, a further 32 men completed both lifts using the Tendo Weightlifting Analyzer Systemz in two identical testing sessions one week apart (session 1 vs. session 2). Intraclass correlation coefficients (ICCs) indicating the validity of the Tendo Weightlifting Analyzer Systemi were high, with values ranging from 0.853 to 0.989. Systematic biases and random errors were low to moderate for almost all variables, being higher in the case of PP (bias ±157.56 W; error ±131.84 W). Proportional biases were identified for almost all variables. Test-retest reliability was strong with ICCs ranging from 0.922 to 0.988. Reliability results also showed minimal systematic biases and random errors, which were only significant for PP (bias -19.19 W; error ±67.57 W). Only PV recorded in the BS showed no significant proportional bias. The Tendo Weightlifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and estimating power in resistance exercises. The low biases and random errors observed here (mainly AV, AP) make this device a useful tool for monitoring resistance training. Key points This study determined the validity and reliability of peak velocity, average velocity, peak power and average power measurements made using a linear position transducer The Tendo Weight-lifting Analyzer Systemi emerged as a reliable system for measuring movement velocity and power. PMID:25729300
ERIC Educational Resources Information Center
Ahn, Christine M.; Ebesutani, Chad; Kamphaus, Randy W.
2014-01-01
The present study was the first to examine the psychometric properties of the Korean version of the Behavior Assessment System for Children-2, Self-Report of Personality, College Version (K-BASC-2 SRP-COL), among a Korean national sample. Using 1,000 Korean college students, ages 18 to 25 years, we found support for the reliability (via internal…
Mauntel, Timothy C; Padua, Darin A; Stanley, Laura E; Frank, Barnett S; DiStefano, Lindsay J; Peck, Karen Y; Cameron, Kenneth L; Marshall, Stephen W
2017-11-01
The Landing Error Scoring System (LESS) can be used to identify individuals with an elevated risk of lower extremity injury. The limitation of the LESS is that raters identify movement errors from video replay, which is time-consuming and, therefore, may limit its use by clinicians. A markerless motion-capture system may be capable of automating LESS scoring, thereby removing this obstacle. To determine the reliability of an automated markerless motion-capture system for scoring the LESS. Cross-sectional study. United States Military Academy. A total of 57 healthy, physically active individuals (47 men, 10 women; age = 18.6 ± 0.6 years, height = 174.5 ± 6.7 cm, mass = 75.9 ± 9.2 kg). Participants completed 3 jump-landing trials that were recorded by standard video cameras and a depth camera. Their movement quality was evaluated by expert LESS raters (standard video recording) using the LESS rubric and by software that automates LESS scoring (depth-camera data). We recorded an error for a LESS item if it was present on at least 2 of 3 jump-landing trials. We calculated κ statistics, prevalence- and bias-adjusted κ (PABAK) statistics, and percentage agreement for each LESS item. Interrater reliability was evaluated between the 2 expert rater scores and between a consensus expert score and the markerless motion-capture system score. We observed reliability between the 2 expert LESS raters (average κ = 0.45 ± 0.35, average PABAK = 0.67 ± 0.34; percentage agreement = 0.83 ± 0.17). The markerless motion-capture system had similar reliability with consensus expert scores (average κ = 0.48 ± 0.40, average PABAK = 0.71 ± 0.27; percentage agreement = 0.85 ± 0.14). However, reliability was poor for 5 LESS items in both LESS score comparisons. A markerless motion-capture system had the same level of reliability as expert LESS raters, suggesting that an automated system can accurately assess movement. Therefore, clinicians can use the markerless motion-capture system to reliably score the LESS without being limited by the time requirements of manual LESS scoring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2015-08-01
Since 1990, the National Renewable Energy Laboratory’s (NREL's) National Wind Technology Center (NWTC) has tested more than 150 wind turbine blades. NWTC researchers can test full-scale and subcomponent articles, conduct data analyses, and provide engineering expertise on best design practices. Structural testing of wind turbine blades enables designers, manufacturers, and owners to validate designs and assess structural performance to specific load conditions. Rigorous structural testing can reveal design and manufacturing problems at an early stage of development that can lead to overall improvements in design and increase system reliability.
Introducing the TAPS Pyramid Model
ERIC Educational Resources Information Center
Earle, Sarah
2015-01-01
The Teacher Assessment in Primary Science (TAPS) project is a three-year project based at Bath Spa University and funded by the Primary Science Teaching Trust (PSTT). It aims to develop support for a valid, reliable and manageable system of science assessment that will have a positive impact on children's learning. In this article, the author…
Methods for assessment of keel bone damage in poultry.
Casey-Trott, T; Heerkens, J L T; Petrik, M; Regmi, P; Schrader, L; Toscano, M J; Widowski, T
2015-10-01
Keel bone damage (KBD) is a critical issue facing the laying hen industry today as a result of the likely pain leading to compromised welfare and the potential for reduced productivity. Recent reports suggest that damage, while highly variable and likely dependent on a host of factors, extends to all systems (including battery cages, furnished cages, and non-cage systems), genetic lines, and management styles. Despite the extent of the problem, the research community remains uncertain as to the causes and influencing factors of KBD. Although progress has been made investigating these factors, the overall effort is hindered by several issues related to the assessment of KBD, including quality and variation in the methods used between research groups. These issues prevent effective comparison of studies, as well as difficulties in identifying the presence of damage leading to poor accuracy and reliability. The current manuscript seeks to resolve these issues by offering precise definitions for types of KBD, reviewing methods for assessment, and providing recommendations that can improve the accuracy and reliability of those assessments. © 2015 Poultry Science Association Inc.
Bedekar, Nilima; Suryawanshi, Mayuri; Rairikar, Savita; Sancheti, Parag; Shyam, Ashok
2014-01-01
Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. Intra-rater reliability using ICC was r=0.920 and inter-rater r=0.812 at CI 95%. Validity r=0.95. Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.
Mitchell, Katy; Graff, Megan; Hedt, Corbin; Simmons, James
2016-08-01
Purpose/hypothesis: This study was designed to investigate the test-retest reliability, concurrent validity, and the standard error of measurement (SEm) of a pulse rate assessment application (Azumio®'s Instant Heart Rate) on both Android® and iOS® (iphone operating system) smartphones as compared to a FT7 Polar® Heart Rate monitor. Number of subjects: 111. Resting (sitting) pulse rate was assessed twice and then the participants were asked to complete a 1-min standing step test and then immediately re-assessed. The smartphone assessors were blinded to their measurements. Test-retest reliability (intraclass correlation coefficient [ICC 2,1] and 95% confidence interval) for the three tools at rest (time 1/time 2): iOS® (0.76 [0.67-0.83]); Polar® (0.84 [0.78-0.89]); and Android® (0.82 [0.75-0.88]). Concurrent validity at rest time 2 (ICC 2,1) with the Polar® device: IOS® (0.92 [0.88-0.94]) and Android® (0.95 [0.92-0.96]). Concurrent validity post-exercise (time 3) (ICC) with the Polar® device: iOS® (0.90 [0.86-0.93]) and Android® (0.94 [0.91-0.96]). The SEm values for the three devices at rest: iOS® (5.77 beats per minute [BPM]), Polar® (4.56 BPM) and Android® (4.96 BPM). The Android®, iOS®, and Polar® devices showed acceptable test-retest reliability at rest and post-exercise. Both the smartphone platforms demonstrated concurrent validity with the Polar® at rest and post-exercise. The Azumio® Instant Heart Rate application when used by either platform appears to be a reliable and valid tool to assess pulse rate in healthy individuals.
Minor, M A; Reid, J C; Griffin, J Z; Pittman, C B; Patrick, T B; Cutts, J H
1998-02-01
To identify innovative strategies to support appropriate, self-directed exercise that increase physical activity levels of people with arthritis. This article reports on one interactive, multimedia exercise performance support system (PSS) for people with lower extremity impairments in strength or flexibility. An interdisciplinary team developed the PSS using self-report of lower extremity musculoskeletal impairments (flexibility and strength) to produce an individualized exercise program with video and print educational materials. Initial evaluation has investigated the validity and reliability of program assessments and recommendations. PSS self-report and professional assessments were similar, with more impairments indicated by self-report. PSS exercise recommendations were similar to those made by 3 expert physical therapists using the same exercise data base. Results of PSS impairment assessments were stable over a 1-week period. PSS exercise recommendations appear to be reliable and a valid reflection of current exercise knowledge in rheumatology. Furthermore, users were able to complete the computer-based program with minimal assistance and reported it to be enjoyable and informative.
Evaluating the Reliability of Emergency Response Systems for Large-Scale Incident Operations
Jackson, Brian A.; Faith, Kay Sullivan; Willis, Henry H.
2012-01-01
Abstract The ability to measure emergency preparedness—to predict the likely performance of emergency response systems in future events—is critical for policy analysis in homeland security. Yet it remains difficult to know how prepared a response system is to deal with large-scale incidents, whether it be a natural disaster, terrorist attack, or industrial or transportation accident. This research draws on the fields of systems analysis and engineering to apply the concept of system reliability to the evaluation of emergency response systems. The authors describe a method for modeling an emergency response system; identifying how individual parts of the system might fail; and assessing the likelihood of each failure and the severity of its effects on the overall response effort. The authors walk the reader through two applications of this method: a simplified example in which responders must deliver medical treatment to a certain number of people in a specified time window, and a more complex scenario involving the release of chlorine gas. The authors also describe an exploratory analysis in which they parsed a set of after-action reports describing real-world incidents, to demonstrate how this method can be used to quantitatively analyze data on past response performance. The authors conclude with a discussion of how this method of measuring emergency response system reliability could inform policy discussion of emergency preparedness, how system reliability might be improved, and the costs of doing so. PMID:28083267
Strutt, Jaclyn K; Mackey, Jennifer E; Johnson, Stephen M; Sylvia, Lynne M
2011-02-01
To evaluate the utility of the 4Ts clinical scoring system as a pretest probability method for the detection of heparin-induced thrombocytopenia (HIT). Prospective observational study. Medical and surgical inpatients at a tertiary care medical center. Eighty consecutive patients with suspicion of HIT who had a polyspecific enzyme-linked immunosorbent assay (ELISA) performed between December 1, 2008, and April 1, 2009, for detection of platelet factor 4 (PF4)-heparin antibodies. The predictive value of the 4Ts scoring system as determined by using a standard laboratory marker of HIT--the ELISA--and the interrater reliability of the scoring system were assessed. Sixty-seven (84%) of the 80 patients had low clinical probability of HIT based on the calculated 4Ts score. The ELISA result was negative for PF4-heparin antibodies in 74 patients (93%). Based on the results of the ELISA, the negative predictive value of the 4Ts score was 91%. Each 4Ts score was calculated by two independent investigators and adjudicated by a third investigator when necessary. The interrater reliability of the scoring system was fair (Cohen κ coefficient 0.362, 95% confidence interval [CI] 0.222-0.502; weighted κ coefficient 0.554 (95% CI 0.441-0.667). Determination of the timing of HIT was associated with the largest number of discrepancies (16) between evaluators, followed by other causes of thrombocytopenia (15), degree of decline in platelet count (14), and the presence of thrombosis or other sequelae (2). A low 4Ts score supports a low probability of HIT based on the results of the polyspecific ELISA. Overall, the interrater reliability of the scoring system was fair. Components of the 4Ts scoring system need to be further clarified or modified in order to improve interrater reliability and thereby increase the clinical utility of this pretest probability model.
Software Fault Tolerance: A Tutorial
NASA Technical Reports Server (NTRS)
Torres-Pomales, Wilfredo
2000-01-01
Because of our present inability to produce error-free software, software fault tolerance is and will continue to be an important consideration in software systems. The root cause of software design errors is the complexity of the systems. Compounding the problems in building correct software is the difficulty in assessing the correctness of software for highly complex systems. After a brief overview of the software development processes, we note how hard-to-detect design faults are likely to be introduced during development and how software faults tend to be state-dependent and activated by particular input sequences. Although component reliability is an important quality measure for system level analysis, software reliability is hard to characterize and the use of post-verification reliability estimates remains a controversial issue. For some applications software safety is more important than reliability, and fault tolerance techniques used in those applications are aimed at preventing catastrophes. Single version software fault tolerance techniques discussed include system structuring and closure, atomic actions, inline fault detection, exception handling, and others. Multiversion techniques are based on the assumption that software built differently should fail differently and thus, if one of the redundant versions fails, it is expected that at least one of the other versions will provide an acceptable output. Recovery blocks, N-version programming, and other multiversion techniques are reviewed.
1992-07-24
Pmo Pbuf Tarr PenvTmm Patneo TTneo Teo Pateo ’,- r 0,Traneo 8 a e P naco Pfa Te aco Tsro- - PPatnen Them, Teyn Pate.. ••==P a• Tat e,- Fr ti I 3 456...Trivedi. Reliability modeling using SHARPE. IEEE Trans. Reliability, R-36(2):186-193, June 1987. 3 [14] K. Salem and H. Garcia-Molina. Disk striping
An Evaluation Methodology for Natural Language Processing Systems
1992-12-01
8217DT".3 "_Griffiss Air Force Base U , . d J _!::! • •, .>:--------. ..._ _. ...........• E v¢ .................. ......... Av,:iabihty Codes Avv L...each " trial " or evaluation item. This approach to assessing reliability has some similarity to the reliability study per- formed by Hix and Schulman for...the clinic . Criteria: Demonstrated understanding that the object or entity expressed by the first noun benefits from the object expressed by the second
Kenyon, Sara; Hewison, Alistair; Dann, Sophie-Anna; Easterbrook, Jolene; Hamilton-Giachritsis, Catherine; Beckmann, April; Johns, Nina
2017-09-18
No standardised system of triage exists in Maternity Care and local audit identified this to be problematic. We designed, implemented and evaluated an Obstetric Triage System in a large UK maternity unit. This includes a standard clinical triage assessment by a midwife, within 15 min of attendance, leading to assignment to a category of clinical urgency (on a 4-category scale). This guides timing of subsequent standardised immediate care for the eight most common reasons for attendance. A training programme was integral to the introduction. A mixed methods evaluation was conducted. A structured audit of 994 sets of maternity notes before and after implementation identified the number of women seen within 15 min of attendance. Secondary measures reviewed included time to subsequent care and attendance. An inter-operator reliability study using scenarios was completed by midwives. A focus group and two questionnaire studies were undertaken to explore midwives' views of the system and to evaluate the training. In addition a national postal survey of practice in UK maternity units was undertaken in 2015. The structured audit of 974/992 (98%) of notes demonstrated an increase in the number of women seen within 15 min of attendance from 39% before implementation to 54% afterwards (RR (95% CI) 1.4 (1.2, 1.7) p = <0.0001). Excellent inter-operator reliability (ICC 0.961 (95% CI 0.91-0.99)) was demonstrated with breakdown showing consistently good rates. Thematic analysis of focus group data (n = 12) informed the development of the questionnaire which was sent to all appropriate midwives. The response rate was 53/79 (67%) and the midwives reported that the new system helped them manage the department and improved safety. The National Survey (response rate 85/135 [63%]) demonstrated wide variation in where women are seen and staffing models in place. The majority of units 69/85 (81%) did not use a triage system based on clinical assessment to prioritise care. This obstetric triage system has excellent inter- operator reliability and appears to be a reliable way of assessing the clinical priority of women as well as improving organisation of the department. Our survey has demonstrated the widespread need for implementation of such a system.
Recent advances in computational structural reliability analysis methods
NASA Astrophysics Data System (ADS)
Thacker, Ben H.; Wu, Y.-T.; Millwater, Harry R.; Torng, Tony Y.; Riha, David S.
1993-10-01
The goal of structural reliability analysis is to determine the probability that the structure will adequately perform its intended function when operating under the given environmental conditions. Thus, the notion of reliability admits the possibility of failure. Given the fact that many different modes of failure are usually possible, achievement of this goal is a formidable task, especially for large, complex structural systems. The traditional (deterministic) design methodology attempts to assure reliability by the application of safety factors and conservative assumptions. However, the safety factor approach lacks a quantitative basis in that the level of reliability is never known and usually results in overly conservative designs because of compounding conservatisms. Furthermore, problem parameters that control the reliability are not identified, nor their importance evaluated. A summary of recent advances in computational structural reliability assessment is presented. A significant level of activity in the research and development community was seen recently, much of which was directed towards the prediction of failure probabilities for single mode failures. The focus is to present some early results and demonstrations of advanced reliability methods applied to structural system problems. This includes structures that can fail as a result of multiple component failures (e.g., a redundant truss), or structural components that may fail due to multiple interacting failure modes (e.g., excessive deflection, resonate vibration, or creep rupture). From these results, some observations and recommendations are made with regard to future research needs.
Recent advances in computational structural reliability analysis methods
NASA Technical Reports Server (NTRS)
Thacker, Ben H.; Wu, Y.-T.; Millwater, Harry R.; Torng, Tony Y.; Riha, David S.
1993-01-01
The goal of structural reliability analysis is to determine the probability that the structure will adequately perform its intended function when operating under the given environmental conditions. Thus, the notion of reliability admits the possibility of failure. Given the fact that many different modes of failure are usually possible, achievement of this goal is a formidable task, especially for large, complex structural systems. The traditional (deterministic) design methodology attempts to assure reliability by the application of safety factors and conservative assumptions. However, the safety factor approach lacks a quantitative basis in that the level of reliability is never known and usually results in overly conservative designs because of compounding conservatisms. Furthermore, problem parameters that control the reliability are not identified, nor their importance evaluated. A summary of recent advances in computational structural reliability assessment is presented. A significant level of activity in the research and development community was seen recently, much of which was directed towards the prediction of failure probabilities for single mode failures. The focus is to present some early results and demonstrations of advanced reliability methods applied to structural system problems. This includes structures that can fail as a result of multiple component failures (e.g., a redundant truss), or structural components that may fail due to multiple interacting failure modes (e.g., excessive deflection, resonate vibration, or creep rupture). From these results, some observations and recommendations are made with regard to future research needs.
ERIC Educational Resources Information Center
Farwell, Tricia M.; Alligood, Leon; Fitzgerald, Sharon; Blake, Ken
2016-01-01
This article introduces an objective grammar and math assessment and evaluates the assessment's outcome and reliability when fielded among eighty-one students in media writing courses. In addition, the article proposes a rubric for grading straight news leads and compares the rubric's reliability with the reliability of rating straight news leads…
Schweitzer, Karl M; Vaccaro, Alexander R; Harrop, James S; Hurlbert, John; Carrino, John A; Rechtine, Glenn R; Schwartz, David G; Alanay, Ahmet; Sharma, Dinesh K; Anderson, D Greg; Lee, Joon Y; Arnold, Paul M
2007-09-01
The Spine Trauma Study Group (STSG) has proposed a novel thoracolumbar injury classification system and score (TLICS) in an attempt to define traumatic spinal injuries and direct appropriate management schemes objectively. The TLICS assigns specific point values based on three variables to generate a final severity score that guides potential treatment options. Within this algorithm, significant emphasis has been placed on posterior ligamentous complex (PLC) integrity. The purpose of this study was to determine the interrater reliability of indicators surgeons use when assessing PLC disruption on imaging studies, including computed tomography (CT) and magnetic resonance imaging (MRI). Orthopedic surgeons and neurosurgeons retrospectively reviewed a series of thoracolumbar injury case studies. Thirteen case studies, including images, were distributed to STSG members for individual, independent evaluation of the following three criteria: (1) diastasis of the facet joints on CT; (2) posterior edema-like signal in the region of PLC components on sagittal T2-weighted fat saturation (FAT SAT) MRI; and (3) disrupted PLC components on sagittal T1-weighted MRI. Interrater agreement on the presence or absence of each of the three criteria in each of the 13 cases was assessed. Absolute interrater percent agreement on diastasis of the facet joints on CT and posterior edema-like signal in the region of PLC components on sagittal T2-weighted FAT SAT MRI was similar (agreement 70.5%). Interrater agreement on disrupted PLC components on sagittal T1-weighted MRI was 48.9%. Facet joint diastasis on CT was the most reliable indicator of PLC disruption as assessed by both Cohen's kappa (kappa = 0.395) and intraclass correlation coefficient (ICC 0.430). The interrater reliability of assessing diastasis of the facet joints on CT had fair to moderate agreement. The reliability of assessing the posterior edema-like signal in the region of PLC components was lower but also fair, whereas the reliability of identifying disrupted PLC components was poor.
Valente, Ana Rita S; Hall, Andreia; Alvelos, Helena; Leahy, Margaret; Jesus, Luis M T
2018-04-12
The appropriate use of language in context depends on the speaker's pragmatic language competencies. A coding system was used to develop a specific and adult-focused self-administered questionnaire to adults who stutter and adults who do not stutter, The Assessment of Language Use in Social Contexts for Adults, with three categories: precursors, basic exchanges, and extended literal/non-literal discourse. This paper presents the content validity, item analysis, reliability coefficients and evidences of construct validity of the instrument. Content validity analysis was based on a two-stage process: first, 11 pragmatic questionnaires were assessed to identify items that probe each pragmatic competency and to create the first version of the instrument; second, items were assessed qualitatively by an expert panel composed by adults who stutter and controls, and quantitatively and qualitatively by an expert panel composed by clinicians. A pilot study was conducted with five adults who stutter and five controls to analyse items and calculate reliability. Construct validity evidences were obtained using the hypothesized relationships method and factor analysis with 28 adults who stutter and 28 controls. Concerning content validity, the questionnaires assessed up to 13 pragmatic competencies. Qualitative and quantitative analysis revealed ambiguities in items construction. Disagreement between experts was solved through item modification. The pilot study showed that the instrument presented internal consistency and temporal stability. Significant differences between adults who stutter and controls and different response profiles revealed the instrument's underlying construct. The instrument is reliable and presented evidences of construct validity.
The feasibility of sharing simulation-based evaluation scenarios in anesthesiology.
Berkenstadt, Haim; Kantor, Gareth S; Yusim, Yakov; Gafni, Naomi; Perel, Azriel; Ezri, Tiberiu; Ziv, Amitai
2005-10-01
We prospectively assessed the feasibility of international sharing of simulation-based evaluation tools despite differences in language, education, and anesthesia practice, in an Israeli study, using validated scenarios from a multi-institutional United States (US) study. Thirty-one Israeli junior anesthesia residents performed four simulation scenarios. Training sessions were videotaped and performance was assessed using two validated scoring systems (Long and Short Forms) by two independent raters. Subjects scored from 37 to 95 (70 +/- 12) of 108 possible points with the "Long Form" and "Short Form" scores ranging from 18 to 35 (28.2 +/- 4.5) of 40 possible points. Scores >70% of the maximal score were achieved by 61% of participants in comparison to only 5% in the original US study. The scenarios were rated as very realistic by 80% of the participants (grade 4 on a 1-4 scale). Reliability of the original assessment tools was demonstrated by internal consistencies of 0.66 for the Long and 0.75 for the Short Form (Cronbach alpha statistic). Values in the original study were 0.72-0.76 for the Long and 0.71-0.75 for the Short Form. The reliability did not change when a revised Israeli version of the scoring was used. Interrater reliability measured by Pearson correlation was 0.91 for the Long and 0.96 for the Short Form (P < 0.01). The high scores for plausibility given to the scenarios and the similar reliability of the original assessment tool support the feasibility of using simulation-based evaluation tools, developed in the US, in Israel. The higher scores achieved by Israeli residents may be related to the fact that most Israeli residents are immigrants with previous training in anesthesia. Simulation-based assessment tools developed in a multi-institutional study in the United States can be used in Israel despite the differences in language, education, and medical system.
Benjamin, Sara E; Neelon, Brian; Ball, Sarah C; Bangdiwala, Shrikant I; Ammerman, Alice S; Ward, Dianne S
2007-01-01
Background Few assessment instruments have examined the nutrition and physical activity environments in child care, and none are self-administered. Given the emerging focus on child care settings as a target for intervention, a valid and reliable measure of the nutrition and physical activity environment is needed. Methods To measure inter-rater reliability, 59 child care center directors and 109 staff completed the self-assessment concurrently, but independently. Three weeks later, a repeat self-assessment was completed by a sub-sample of 38 directors to assess test-retest reliability. To assess criterion validity, a researcher-administered environmental assessment was conducted at 69 centers and was compared to a self-assessment completed by the director. A weighted kappa test statistic and percent agreement were calculated to assess agreement for each question on the self-assessment. Results For inter-rater reliability, kappa statistics ranged from 0.20 to 1.00 across all questions. Test-retest reliability of the self-assessment yielded kappa statistics that ranged from 0.07 to 1.00. The inter-quartile kappa statistic ranges for inter-rater and test-retest reliability were 0.45 to 0.63 and 0.27 to 0.45, respectively. When percent agreement was calculated, questions ranged from 52.6% to 100% for inter-rater reliability and 34.3% to 100% for test-retest reliability. Kappa statistics for validity ranged from -0.01 to 0.79, with an inter-quartile range of 0.08 to 0.34. Percent agreement for validity ranged from 12.9% to 93.7%. Conclusion This study provides estimates of criterion validity, inter-rater reliability and test-retest reliability for an environmental nutrition and physical activity self-assessment instrument for child care. Results indicate that the self-assessment is a stable and reasonably accurate instrument for use with child care interventions. We therefore recommend the Nutrition and Physical Activity Self-Assessment for Child Care (NAP SACC) instrument to researchers and practitioners interested in conducting healthy weight intervention in child care. However, a more robust, less subjective measure would be more appropriate for researchers seeking an outcome measure to assess intervention impact. PMID:17615078
A rainwater harvesting system reliability model based on nonparametric stochastic rainfall generator
NASA Astrophysics Data System (ADS)
Basinger, Matt; Montalto, Franco; Lall, Upmanu
2010-10-01
SummaryThe reliability with which harvested rainwater can be used as a means of flushing toilets, irrigating gardens, and topping off air-conditioner serving multifamily residential buildings in New York City is assessed using a new rainwater harvesting (RWH) system reliability model. Although demonstrated with a specific case study, the model is portable because it is based on a nonparametric rainfall generation procedure utilizing a bootstrapped markov chain. Precipitation occurrence is simulated using transition probabilities derived for each day of the year based on the historical probability of wet and dry day state changes. Precipitation amounts are selected from a matrix of historical values within a moving 15 day window that is centered on the target day. RWH system reliability is determined for user-specified catchment area and tank volume ranges using precipitation ensembles generated using the described stochastic procedure. The reliability with which NYC backyard gardens can be irrigated and air conditioning units supplied with water harvested from local roofs exceeds 80% and 90%, respectively, for the entire range of catchment areas and tank volumes considered in the analysis. For RWH systems installed on the most commonly occurring rooftop catchment areas found in NYC (51-75 m 2), toilet flushing demand can be met with 7-40% reliability, with lower end of the range representing buildings with high flow toilets and no storage elements, and the upper end representing buildings that feature low flow fixtures and storage tanks of up to 5 m 3. When the reliability curves developed are used to size RWH systems to flush the low flow toilets of all multifamily buildings found a typical residential neighborhood in the Bronx, rooftop runoff inputs to the sewer system are reduced by approximately 28% over an average rainfall year, and potable water demand is reduced by approximately 53%.
Seligman, Sarah C; Giovannetti, Tania; Sestito, John; Libon, David J
2014-01-01
Mild functional difficulties have been associated with early cognitive decline in older adults and increased risk for conversion to dementia in mild cognitive impairment, but our understanding of this decline has been limited by a dearth of objective methods. This study evaluated the reliability and validity of a new system to code subtle errors on an established performance-based measure of everyday action and described preliminary findings within the context of a theoretical model of action disruption. Here 45 older adults completed the Naturalistic Action Test (NAT) and neuropsychological measures. NAT performance was coded for overt errors, and subtle action difficulties were scored using a novel coding system. An inter-rater reliability coefficient was calculated. Validity of the coding system was assessed using a repeated-measures ANOVA with NAT task (simple versus complex) and error type (overt versus subtle) as within-group factors. Correlation/regression analyses were conducted among overt NAT errors, subtle NAT errors, and neuropsychological variables. The coding of subtle action errors was reliable and valid, and episodic memory breakdown predicted subtle action disruption. Results suggest that the NAT can be useful in objectively assessing subtle functional decline. Treatments targeting episodic memory may be most effective in addressing early functional impairment in older age.
CRAX/Cassandra Reliability Analysis Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, D.
1999-02-10
Over the past few years Sandia National Laboratories has been moving toward an increased dependence on model- or physics-based analyses as a means to assess the impact of long-term storage on the nuclear weapons stockpile. These deterministic models have also been used to evaluate replacements for aging systems, often involving commercial off-the-shelf components (COTS). In addition, the models have been used to assess the performance of replacement components manufactured via unique, small-lot production runs. In either case, the limited amount of available test data dictates that the only logical course of action to characterize the reliability of these components ismore » to specifically consider the uncertainties in material properties, operating environment etc. within the physics-based (deterministic) model. This not only provides the ability to statistically characterize the expected performance of the component or system, but also provides direction regarding the benefits of additional testing on specific components within the system. An effort was therefore initiated to evaluate the capabilities of existing probabilistic methods and, if required, to develop new analysis methods to support the inclusion of uncertainty in the classical design tools used by analysts and design engineers at Sandia. The primary result of this effort is the CMX (Cassandra Exoskeleton) reliability analysis software.« less
Changoor, A; Tran-Khanh, N; Méthot, S; Garon, M; Hurtig, M B; Shive, M S; Buschmann, M D
2011-01-01
Collagen organization, a feature that is critical for cartilage load bearing and durability, is not adequately assessed in cartilage repair tissue by present histological scoring systems. Our objectives were to develop a new polarized light microscopy (PLM) score for collagen organization and to test its reliability. This PLM score uses an ordinal scale of 0-5 to rate the extent that collagen network organization resembles that of young adult hyaline articular cartilage (score of 5) vs a totally disorganized tissue (score of 0). Inter-reader reliability was assessed using Intraclass Correlation Coefficients (ICC) for Agreement, calculated from scores of three trained readers who independently evaluated blinded sections obtained from normal (n=4), degraded (n=2) and repair (n=22) human cartilage biopsies. The PLM score succeeded in distinguishing normal, degraded and repair cartilages, where the latter displayed greater complexity in collagen structure. Excellent inter-reader reproducibility was found with ICCs for Agreement of 0.90 [ICC(2,1)] (lower boundary of the 95% confidence interval is 0.83) and 0.96 [ICC(2,3)] (lower boundary of the 95% confidence interval is 0.94), indicating the reliability of a single reader's scores and the mean of all three readers' scores, respectively. This PLM method offers a novel means for systematically evaluating collagen organization in repair cartilage. We propose that it be used to supplement current gold standard histological scoring systems for a more complete assessment of repair tissue quality. Copyright © 2010 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Animal-Based Measures to Assess the Welfare of Extensively Managed Ewes
Hemsworth, Paul; Doyle, Rebecca
2017-01-01
Simple Summary The aim of this study was to assess the reliability and practicality of 10 animal-based welfare measures for extensively managed ewes, which were derived from the scientific literature, previous welfare protocols and through consultation with veterinarians and animal welfare scientists. Measures were examined on 100 Merino ewes, which were individually identified and repeatedly examined at mid-pregnancy, mid-lactation and weaning. Body condition score, fleece condition, skin lesions, tail length, dag score and lameness are proposed for on-farm use in welfare assessments of extensive sheep production systems. These six welfare measures, which address the main welfare concerns for extensively managed ewes, can be reliably and feasibly measured in the field. Abstract The reliability and feasibility of 10 animal-based measures of ewe welfare were examined for use in extensive sheep production systems. Measures were: Body condition score (BCS), rumen fill, fleece cleanliness, fleece condition, skin lesions, tail length, dag score, foot-wall integrity, hoof overgrowth and lameness, and all were examined on 100 Merino ewes (aged 2–4 years) during mid-pregnancy, mid-lactation and weaning by a pool of nine trained observers. The measures of BCS, fleece condition, skin lesions, tail length, dag score and lameness were deemed to be reliable and feasible. All had good observer agreement, as determined by the percentage of agreement, Kendall’s coefficient of concordance (W) and Kappa (k) values. When combined, these nutritional and health measures provide a snapshot of the current welfare status of ewes, as well as evidencing previous or potential welfare issues. PMID:29295551
Drew Sayer, R; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W
2016-10-01
The brain's reward system influences ingestive behavior and subsequently obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. This study sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n = 16) and men (n = 12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the two testing days. Mean fasting-state brain responses on day 2 were reduced compared with day 1 in the left insula and right amygdala, but mean day 1 and day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. © 2016 The Obesity Society.
Sayer, R Drew; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W
2016-01-01
Objective The brain’s reward system influences ingestive behavior and subsequently, obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. We sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. Methods A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n=16) and men (n=12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the 2 testing days. Results Mean fasting-state brain responses on Day 2 were reduced compared to Day 1 in the left insula and right amygdala, but mean Day 1 and Day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. Conclusion fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility, but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. PMID:27542906
Implementing an obstetric triage acuity scale: interrater reliability and patient flow analysis.
Smithson, David S; Twohey, Rachel; Rice, Tim; Watts, Nancy; Fernandes, Christopher M; Gratton, Robert J
2013-10-01
A 5-category Obstetric Triage Acuity Scale (OTAS) was developed with a comprehensive set of obstetrical determinants. The objectives of this study were as follows: (1) to test the interrater reliability of OTAS and (2) to determine the distribution of patient acuity and flow by OTAS level. To test the interrater reliability, 110 triage charts were used to generate vignettes and the consistency of the OTAS level assigned by 8 triage nurses was measured. OTAS performed with substantial (Kappa, 0.61 - 0.77, OTAS 1-4) and near perfect correlation (0.87, OTAS 5). To assess patient flow, the times to primary and secondary health care provider assessments and lengths of stay stratified by acuity were abstracted from the patient management system. Two-thirds of triage visits were low acuity (OTAS 4, 5). There was a decrease in length of stay (median [interquartile range], minutes) as acuity decreased from OTAS 1 (120.0 [156.0] minutes) to OTAS 3 (75.0 [120.8]). The major contributor to length of stay was time to secondary health care provider assessment and this did not change with acuity. The percentage of patients admitted to the antenatal or birthing unit decreased from 80% (OTAS 1) to 12% (OTAS 5). OTAS provides a reliable assessment of acuity and its implementation has allowed for triaging of obstetric patients based on acuity, and a more in-depth assessment of the patient flow. By standardizing assessment, OTAS allows for opportunities to improve performance and make comparisons of patient care and flow across organizations. Copyright © 2013 Mosby, Inc. All rights reserved.
The reliability of in-training assessment when performance improvement is taken into account.
van Lohuizen, Mirjam T; Kuks, Jan B M; van Hell, Elisabeth A; Raat, A N; Stewart, Roy E; Cohen-Schotanus, Janke
2010-12-01
During in-training assessment students are frequently assessed over a longer period of time and therefore it can be expected that their performance will improve. We studied whether there really is a measurable performance improvement when students are assessed over an extended period of time and how this improvement affects the reliability of the overall judgement. In-training assessment results were obtained from 104 students on rotation at our university hospital or at one of the six affiliated hospitals. Generalisability theory was used in combination with multilevel analysis to obtain reliability coefficients and to estimate the number of assessments needed for reliable overall judgement, both including and excluding performance improvement. Students' clinical performance ratings improved significantly from a mean of 7.6 at the start to a mean of 7.8 at the end of their clerkship. When taking performance improvement into account, reliability coefficients were higher. The number of assessments needed to achieve a reliability of 0.80 or higher decreased from 17 to 11. Therefore, when studying reliability of in-training assessment, performance improvement should be considered.
Burns, Clare L; Ward, Elizabeth C; Hill, Anne J; Phillips, Nick; Porter, Linda
2016-06-01
A small number of studies have examined the feasibility of conducting videofluoroscopic swallow studies (VFSS) via telepractice. While the results have confirmed this potential, the systems tested to date have either reported issues that impacted the ability to analyze/interpret the VFSS recordings in real time, or they were not designed to enable real-time interpretation. Further system design is needed to establish a telepractice model that enables the VFSS assessment to be both guided and interpreted live in real time. The aim of this study was to test the feasibility and reliability of using a telepractice system to enable live VFSS assessment. Twenty adult patients underwent a VFSS assessment directed by a telepractice SLP with competency in VFSS located in another room of the hospital. The telepractice clinician led the sessions using a C20 Cisco TelePresence System. This was linked in real time via a secure telehealth network (at 4 megabits per second (Mbit/s)) to a C60 Cisco TelePresence System located in a fluoroscopy suite, connected to the digital fluoroscopy system. Levels of agreement were calculated between the telepractice clinician and a face-to-face clinician who simultaneously rated the VFSS in real time. High levels of agreement for swallowing parameters (range = 75-100 %; k = -0.34 to 1.0) and management decisions (range = 70-100 %, k = 0.64-1.0) were found. A post-session questionnaire revealed clinicians agreed that the telepractice system enabled successful remote assessment of VFSS. The findings support the potential to conduct live VFSS assessment via a telepractice model.
Magnan, Morris A; Maklebust, Joann
2008-01-01
To evaluate the effect of Web-based Braden Scale training on the reliability and precision of pressure ulcer risk assessments made by registered nurses (RN) working in acute care settings. Pretest-posttest, 2-group, quasi-experimental design. Five hundred Braden Scale risk assessments were made on 102 acute care patients deemed to be at various levels of risk for pressure ulceration. Assessments were made by RNs working in acute care hospitals at 3 different medical centers where the Braden Scale was in regular daily use (2 medical centers) or new to the setting (1 medical center). The Braden Scale for Predicting Pressure Sore Risk was used to guide pressure ulcer risk assessments. A Web-based version of the Detroit Medical Center Braden Scale Computerized Training Module was used to teach nurses correct use of the Braden Scale and selection of risk-based pressure ulcer prevention interventions. In the aggregate, RN generated reliable Braden Scale pressure ulcer risk assessments 65% of the time after training. The effect of Web-based Braden Scale training on reliability and precision of assessments varied according to familiarity with the scale. With training, new users of the scale made reliable assessments 84% of the time and significantly improved precision of their assessments. The reliability and precision of Braden Scale risk assessments made by its regular users was unaffected by training. Technology-assisted Braden Scale training improved both reliability and precision of risk assessments made by new users of the scale, but had virtually no effect on the reliability or precision of risk assessments made by regular users of the instrument. Further research is needed to determine best approaches for improving reliability and precision of Braden Scale assessments made by its regular users.
Brown, Laura J E; Adlam, Tim; Hwang, Faustina; Khadra, Hassan; Maclean, Linda M; Rudd, Bridey; Smith, Tom; Timon, Claire; Williams, Elizabeth A; Astell, Arlene J
2016-08-01
Patterns of cognitive change over micro-longitudinal timescales (i.e., ranging from hours to days) are associated with a wide range of age-related health and functional outcomes. However, practical issues of conducting high-frequency assessments make investigations of micro-longitudinal cognition costly and burdensome to run. One way of addressing this is to develop cognitive assessments that can be performed by older adults, in their own homes, without a researcher being present. Here, we address the question of whether reliable and valid cognitive data can be collected over micro-longitudinal timescales using unsupervised cognitive tests.In study 1, 48 older adults completed two touchscreen cognitive tests, on three occasions, in controlled conditions, alongside a battery of standard tests of cognitive functions. In study 2, 40 older adults completed the same two computerized tasks on multiple occasions, over three separate week-long periods, in their own homes, without a researcher present. Here, the tasks were incorporated into a wider touchscreen system (Novel Assessment of Nutrition and Ageing (NANA)) developed to assess multiple domains of health and behavior. Standard tests of cognitive function were also administered prior to participants using the NANA system.Performance on the two "NANA" cognitive tasks showed convergent validity with, and similar levels of reliability to, the standard cognitive battery in both studies. Completion and accuracy rates were also very high. These results show that reliable and valid cognitive data can be collected from older adults using unsupervised computerized tests, thus affording new opportunities for the investigation of cognitive.
Reliability of the dynavision™ d2 for assessing reaction time performance.
Wells, Adam J; Hoffman, Jay R; Beyer, Kyle S; Jajtner, Adam R; Gonzalez, Adam M; Townsend, Jeremy R; Mangine, Gerald T; Robinson, Edward H; McCormack, William P; Fragala, Maren S; Stout, Jeffrey R
2014-01-01
Recently, the Dynavision™ D2 Visuomotor Training Device (D2) has emerged as a tool in the assessment of reaction time (RT); however, information regarding the reliability of the D2 have been limited, and to date, reliability data have been limited to non- generalizable samples. Therefore, the purpose of this study was to establish intraclass correlation coefficients (ICC2,1) for the D2 that are generalizable across a population of recreationally active young adults. Forty-two recreationally active men and women (age: 23.41 ± 4.84 years; height: 1.72 ± 0.11 m; mass: 76.62 ± 18.26 Kg) completed 6 trials for three RT tasks of increasing complexity. Each trial was separated by at least 48-hours. A repeated measures ANOVA was used to detect differences in performance across the six trials. Intraclass correlation coefficients (ICC2,1) standard error of measurement (SEM), and minimal differences (MD) were used to determine the reliability of the D2 from the two sessions with the least significant difference score. Moderate to strong reliability was demonstrated for visual RT (ICC2,1: 0.84, SEM: 0.033), and reactive ability in both Mode A and Mode B tasks (Mode A hits: ICC2,1: 0.75, SEM: 5.44; Mode B hits: ICC2,1: 0.73, SEM: 8.57). Motor RT (ICC2,1: 0.63, SEM: 0.035s) showed fair reliability, while average RT per hit for Modes A and B showed moderate reliability (ICC2,1: 0.68, SEM: 0.43 s and ICC2,1: 0.72, SEM: 0.03 s respectively). It appears that one familiarization trial is necessary for the choice reaction time (CRT) task while three familiarization trials are necessary for reactive RT tasks. In conclusion, results indicate that the Dynavision™ D2 is a reliable device to assess neuromuscular reactivity given that an adequate practice is provided. The data presented are generalizable to a population of recreationally active young adults. Key PointsThe Dynavision™ D2 is a light-training reaction device, developed to train sensory motor integration through the visual system, offering the ability to assess visual and motor reaction to both central and peripheral stimuli, with a capacity to integrate increasing levels of cognitive challenge.The Dynavision™ D2 is a reliable instrument for assessing reaction time in recreationally active young adults.It is recommended that one familiarization trial is necessary for the choice reaction time task assessment to learn the test protocol, while three familiarization trials are needed for reactive ability in Mode A and Mode B before a subsequent reliable baseline score can be established.Significant training effects were observed for all reaction time tests and should be taken into account with continuous trials.
Majuru, Batsirai; Jagals, Paul; Hunter, Paul R
2012-10-01
Although a number of studies have reported on water supply improvements, few have simultaneously taken into account the reliability of the water services. The study aimed to assess whether upgrading water supply systems in small rural communities improved access, availability and potability of water by assessing the water services against selected benchmarks from the World Health Organisation and South African Department of Water Affairs, and to determine the impact of unreliability on the services. These benchmarks were applied in three rural communities in Limpopo, South Africa where rudimentary water supply services were being upgraded to basic services. Data were collected through structured interviews, observations and measurement, and multi-level linear regression models were used to assess the impact of water service upgrades on key outcome measures of distance to source, daily per capita water quantity and Escherichia coli count. When the basic system was operational, 72% of households met the minimum benchmarks for distance and water quantity, but only 8% met both enhanced benchmarks. During non-operational periods of the basic service, daily per capita water consumption decreased by 5.19l (p<0.001, 95% CI 4.06-6.31) and distances to water sources were 639 m further (p ≤ 0.001, 95% CI 560-718). Although both rudimentary and basic systems delivered water that met potability criteria at the sources, the quality of stored water sampled in the home was still unacceptable throughout the various service levels. These results show that basic water services can make substantial improvements to water access, availability, potability, but only if such services are reliable. Copyright © 2012 Elsevier B.V. All rights reserved.
Gray, Aaron D; Willis, Brad W; Skubic, Marjorie; Huo, Zhiyu; Razu, Swithin; Sherman, Seth L; Guess, Trent M; Jahandar, Amirhossein; Gulbrandsen, Trevor R; Miller, Scott; Siesener, Nathan J
Noncontact anterior cruciate ligament (ACL) injury in adolescent female athletes is an increasing problem. The knee-ankle separation ratio (KASR), calculated at initial contact (IC) and peak flexion (PF) during the drop vertical jump (DVJ), is a measure of dynamic knee valgus. The Microsoft Kinect V2 has shown promise as a reliable and valid marker-less motion capture device. The Kinect V2 will demonstrate good to excellent correlation between KASR results at IC and PF during the DVJ, as compared with a "gold standard" Vicon motion analysis system. Descriptive laboratory study. Level 2. Thirty-eight healthy volunteer subjects (20 male, 18 female) performed 5 DVJ trials, simultaneously measured by a Vicon MX-T40S system, 2 AMTI force platforms, and a Kinect V2 with customized software. A total of 190 jumps were completed. The KASR was calculated at IC and PF during the DVJ. The intraclass correlation coefficient (ICC) assessed the degree of KASR agreement between the Kinect and Vicon systems. The ICCs of the Kinect V2 and Vicon KASR at IC and PF were 0.84 and 0.95, respectively, showing excellent agreement between the 2 measures. The Kinect V2 successfully identified the KASR at PF and IC frames in 182 of 190 trials, demonstrating 95.8% reliability. The Kinect V2 demonstrated excellent ICC of the KASR at IC and PF during the DVJ when compared with the Vicon system. A customized Kinect V2 software program demonstrated good reliability in identifying the KASR at IC and PF during the DVJ. Reliable, valid, inexpensive, and efficient screening tools may improve the accessibility of motion analysis assessment of adolescent female athletes.
NASA Technical Reports Server (NTRS)
1991-01-01
The technical effort and computer code enhancements performed during the sixth year of the Probabilistic Structural Analysis Methods program are summarized. Various capabilities are described to probabilistically combine structural response and structural resistance to compute component reliability. A library of structural resistance models is implemented in the Numerical Evaluations of Stochastic Structures Under Stress (NESSUS) code that included fatigue, fracture, creep, multi-factor interaction, and other important effects. In addition, a user interface was developed for user-defined resistance models. An accurate and efficient reliability method was developed and was successfully implemented in the NESSUS code to compute component reliability based on user-selected response and resistance models. A risk module was developed to compute component risk with respect to cost, performance, or user-defined criteria. The new component risk assessment capabilities were validated and demonstrated using several examples. Various supporting methodologies were also developed in support of component risk assessment.
Assessing fundamental 2-dimensional understanding of basic soft tissue techniques.
Jabbour, Noel; Dobratz, Eric J; Dresner, Harley S; Hilger, Peter A
2011-01-01
To develop a written practical examination and scoring system for assessing trainee skills in basic soft-tissue techniques. A brief written practical examination was developed to assess the ability of trainees to sketch preoperative plans and postoperative results for common soft-tissue techniques: simple-excision, M-plasty, geometric broken line closure, Z-plasty, V-to-Y flap, and rhombic flap. A scoring system was developed to assign 0 to 5 points to each of 10 items on the examination for a total score of 0-50. The 15-minute examination was administered as a pretest, posttest, and 3-month posttest assessment as part of a soft-tissue course at our institution. University of Minnesota, Otolaryngology Department. Three raters reviewed all examination answer sheets independently. The pretest scores of examinees correlated strongly with their level of training; the average pretest for junior residents (PGY 1-2) compared with senior residents (PGY 4-5) was 17.3 (of 50) versus 26.0 (p < 0.01). The scoring system showed a high intrarater reliability and high interrater reliability with correlation coefficients of r = 0.99 and r = 0.95, respectively and agreement coefficients of κ = 0.82 and κ = 0.77, respectively. This written practical examination and scoring system may be used to assess the skills of trainees accurately in basic soft tissue techniques and to expose areas of deficiency that can be addressed in future training sessions. Copyright © 2011 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Majid, Imran; Haq, Inaamul; Imran, Saher; Keen, Abid; Aziz, Khalid; Arif, Tasleem
2016-01-01
Background: Melasma Area and Severity Index (MASI), the scoring system in melasma, needs to be refined. Aims and Objectives: To propose a more practical scoring system, named as Melasma Severity Index (MSI), for assessing the disease severity and treatment response in melasma. Materials and Methods: Four dermatologists were trained to calculate MASI and also the proposed MSI scores. For MSI, the formula used was 0.4 (a × p2) l + 0.4 (a × p2) r + 0.2 (a × p2) n where “a” stands for area, “p” for pigmentation, “l” for left face, “r” for right face, and “n” for nose. On a single day, 30 enrolled patients were randomly examined by each trained dermatologist and their MASI and MSI scores were calculated. Next, each rater re-examined every 6th patient for repeat MASI and MSI scoring to assess intra- and inter-rater reliability of MASI and MSI scores. Validity was assessed by comparing the individual scores of each rater with objective data from mexameter and ImageJ software. Results: Inter-rater reliability, as assessed by intraclass correlation coefficient, was significantly higher for MSI (0.955) as compared to MASI (0.816). Correlation of scores with objective data by Spearman's correlation revealed higher rho values for MSI than for MASI for all raters. Limitations: Sample population belonged to a single ethnic group. Conclusions: MSI is simpler and more practical scoring system for melasma. PMID:26955093
Classification in childhood disability: focusing on function in the 21st century.
Rosenbaum, Peter; Eliasson, Ann-Christin; Hidecker, Mary Jo Cooley; Palisano, Robert J
2014-08-01
Classification systems in health care are usually based on current understanding of the condition. They are often derived empirically and adopted applying sound principles of measurement science to assess whether they are reliable (consistent) and valid (true) for the purposes to which they are applied. In the past 15 years, the authors have developed and validated classification systems for specific aspects of everyday function in people with cerebral palsy--gross motor function, manual abilities, and communicative function. This article describes the approaches used to conceptualize each aspect of function, develop the tools, and assess their reliability and validity. We report on the utility of each system with respect to clinical applicability, use of these tools for research, and the uptake and impact that they have had around the world. We hope that readers will find these accounts interesting, relevant, and applicable to their daily work with children and youth with disabilities. © The Author(s) 2014.
Radiation-Tolerance Assessment of a Redundant Wireless Device
NASA Astrophysics Data System (ADS)
Huang, Q.; Jiang, J.
2018-01-01
This paper presents a method to evaluate radiation-tolerance without physical tests for a commercial off-the-shelf (COTS)-based monitoring device for high level radiation fields, such as those found in post-accident conditions in a nuclear power plant (NPP). This paper specifically describes the analysis of radiation environment in a severe accident, radiation damages in electronics, and the redundant solution used to prolong the life of the system, as well as the evaluation method for radiation protection and the analysis method of system reliability. As a case study, a wireless monitoring device with redundant and diversified channels is evaluated by using the developed method. The study results and system assessment data show that, under the given radiation condition, performance of the redundant device is more reliable and more robust than those non-redundant devices. The developed redundant wireless monitoring device is therefore able to apply in those conditions (up to 10 M Rad (Si)) during a severe accident in a NPP.
Design and validation of an automated hydrostatic weighing system.
McClenaghan, B A; Rocchio, L
1986-08-01
The purpose of this study was to design and evaluate the validity of an automated technique to assess body density using a computerized hydrostatic weighing system. An existing hydrostatic tank was modified and interfaced with a microcomputer equipped with an analog-to-digital converter. Software was designed to input variables, control the collection of data, calculate selected measurements, and provide a summary of the results of each session. Validity of the data obtained utilizing the automated hydrostatic weighing system was estimated by: evaluating the reliability of the transducer/computer interface to measure objects of known underwater weight; comparing the data against a criterion measure; and determining inter-session subject reliability. Values obtained from the automated system were found to be highly correlated with known underwater weights (r = 0.99, SEE = 0.0060 kg). Data concurrently obtained utilizing the automated system and a manual chart recorder were also found to be highly correlated (r = 0.99, SEE = 0.0606 kg). Inter-session subject reliability was determined utilizing data collected on subjects (N = 16) tested on two occasions approximately 24 h apart. Correlations revealed high relationships between measures of underwater weight (r = 0.99, SEE = 0.1399 kg) and body density (r = 0.98, SEE = 0.00244 g X cm-1). Results indicate that a computerized hydrostatic weighing system is a valid and reliable method for determining underwater weight.
NASA Technical Reports Server (NTRS)
1993-01-01
The Marshall Space Flight Center is responsible for the development and management of advanced launch vehicle propulsion systems, including the Space Shuttle Main Engine (SSME), which is presently operational, and the Space Transportation Main Engine (STME) under development. The SSME's provide high performance within stringent constraints on size, weight, and reliability. Based on operational experience, continuous design improvement is in progress to enhance system durability and reliability. Specialized data analysis and interpretation is required in support of SSME and advanced propulsion system diagnostic evaluations. Comprehensive evaluation of the dynamic measurements obtained from test and flight operations is necessary to provide timely assessment of the vibrational characteristics indicating the operational status of turbomachinery and other critical engine components. Efficient performance of this effort is critical due to the significant impact of dynamic evaluation results on ground test and launch schedules, and requires direct familiarity with SSME and derivative systems, test data acquisition, and diagnostic software. Detailed analysis and evaluation of dynamic measurements obtained during SSME and advanced system ground test and flight operations was performed including analytical/statistical assessment of component dynamic behavior, and the development and implementation of analytical/statistical models to efficiently define nominal component dynamic characteristics, detect anomalous behavior, and assess machinery operational condition. In addition, the SSME and J-2 data will be applied to develop vibroacoustic environments for advanced propulsion system components, as required. This study will provide timely assessment of engine component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. This contract will be performed through accomplishment of negotiated task orders.
Defining and assessing professional competence.
Epstein, Ronald M; Hundert, Edward M
2002-01-09
Current assessment formats for physicians and trainees reliably test core knowledge and basic skills. However, they may underemphasize some important domains of professional medical practice, including interpersonal skills, lifelong learning, professionalism, and integration of core knowledge into clinical practice. To propose a definition of professional competence, to review current means for assessing it, and to suggest new approaches to assessment. We searched the MEDLINE database from 1966 to 2001 and reference lists of relevant articles for English-language studies of reliability or validity of measures of competence of physicians, medical students, and residents. We excluded articles of a purely descriptive nature, duplicate reports, reviews, and opinions and position statements, which yielded 195 relevant citations. Data were abstracted by 1 of us (R.M.E.). Quality criteria for inclusion were broad, given the heterogeneity of interventions, complexity of outcome measures, and paucity of randomized or longitudinal study designs. We generated an inclusive definition of competence: the habitual and judicious use of communication, knowledge, technical skills, clinical reasoning, emotions, values, and reflection in daily practice for the benefit of the individual and the community being served. Aside from protecting the public and limiting access to advanced training, assessments should foster habits of learning and self-reflection and drive institutional change. Subjective, multiple-choice, and standardized patient assessments, although reliable, underemphasize important domains of professional competence: integration of knowledge and skills, context of care, information management, teamwork, health systems, and patient-physician relationships. Few assessments observe trainees in real-life situations, incorporate the perspectives of peers and patients, or use measures that predict clinical outcomes. In addition to assessments of basic skills, new formats that assess clinical reasoning, expert judgment, management of ambiguity, professionalism, time management, learning strategies, and teamwork promise a multidimensional assessment while maintaining adequate reliability and validity. Institutional support, reflection, and mentoring must accompany the development of assessment programs.
Silsupadol, Patima; Teja, Kunlanan; Lugade, Vipul
2017-10-01
The assessment of spatiotemporal gait parameters is a useful clinical indicator of health status. Unfortunately, most assessment tools require controlled laboratory environments which can be expensive and time consuming. As smartphones with embedded sensors are becoming ubiquitous, this technology can provide a cost-effective, easily deployable method for assessing gait. Therefore, the purpose of this study was to assess the reliability and validity of a smartphone-based accelerometer in quantifying spatiotemporal gait parameters when attached to the body or in a bag, belt, hand, and pocket. Thirty-four healthy adults were asked to walk at self-selected comfortable, slow, and fast speeds over a 10-m walkway while carrying a smartphone. Step length, step time, gait velocity, and cadence were computed from smartphone-based accelerometers and validated with GAITRite. Across all walking speeds, smartphone data had excellent reliability (ICC 2,1 ≥0.90) for the body and belt locations, with bag, hand, and pocket locations having good to excellent reliability (ICC 2,1 ≥0.69). Correlations between the smartphone-based and GAITRite-based systems were very high for the body (r=0.89, 0.98, 0.96, and 0.87 for step length, step time, gait velocity, and cadence, respectively). Similarly, Bland-Altman analysis demonstrated that the bias approached zero, particularly in the body, bag, and belt conditions under comfortable and fast speeds. Thus, smartphone-based assessments of gait are most valid when placed on the body, in a bag, or on a belt. The use of a smartphone to assess gait can provide relevant data to clinicians without encumbering the user and allow for data collection in the free-living environment. Copyright © 2017 Elsevier B.V. All rights reserved.
[Combined forecasting system of peritonitis outcome].
Lebedev, N V; Klimov, A E; Agrba, S B; Gaidukevich, E K
To create a reliable system for assessing of severity and prediction of the outcome of peritonitis. Critical analysis of the systems for peritonitis severity assessment is presented. The study included outcomes of 347 patients who admitted at the Department of Faculty Surgery of Peoples' Friendship University of Russia in 2015-2016. The cause of peritonitis were destructive forms of acute appendicitis, cholecystitis, perforated gastroduodenal ulcer, various perforation of small and large intestines (including tumor). Combined forecasting system for peritonitis severity assessment is created. The system includes clinical, laboratory data, assessment of systemic inflammatory response (SIRS) and severity of organ failure (qSOFA). The authors focused on easily identifiable parameters which are available in virtually any surgical hospital. Threshold value (lethal outcome probability over 50%) is 8 scores in this system. Sensitivity, specificity and accuracy were 93.3, 99.7 and 98.9%, respectively according to ROC-curve that exceeds those parameters of MPI and APACHE II.
NASA Astrophysics Data System (ADS)
Lo, Men-Tzung; Hu, Kun; Liu, Yanhui; Peng, C.-K.; Novak, Vera
2008-12-01
Quantification of nonlinear interactions between two nonstationary signals presents a computational challenge in different research fields, especially for assessments of physiological systems. Traditional approaches that are based on theories of stationary signals cannot resolve nonstationarity-related issues and, thus, cannot reliably assess nonlinear interactions in physiological systems. In this review we discuss a new technique called multimodal pressure flow (MMPF) method that utilizes Hilbert-Huang transformation to quantify interaction between nonstationary cerebral blood flow velocity (BFV) and blood pressure (BP) for the assessment of dynamic cerebral autoregulation (CA). CA is an important mechanism responsible for controlling cerebral blood flow in responses to fluctuations in systemic BP within a few heart-beats. The MMPF analysis decomposes BP and BFV signals into multiple empirical modes adaptively so that the fluctuations caused by a specific physiologic process can be represented in a corresponding empirical mode. Using this technique, we showed that dynamic CA can be characterized by specific phase delays between the decomposed BP and BFV oscillations, and that the phase shifts are significantly reduced in hypertensive, diabetics and stroke subjects with impaired CA. Additionally, the new technique can reliably assess CA using both induced BP/BFV oscillations during clinical tests and spontaneous BP/BFV fluctuations during resting conditions.
Data driven CAN node reliability assessment for manufacturing system
NASA Astrophysics Data System (ADS)
Zhang, Leiming; Yuan, Yong; Lei, Yong
2017-01-01
The reliability of the Controller Area Network(CAN) is critical to the performance and safety of the system. However, direct bus-off time assessment tools are lacking in practice due to inaccessibility of the node information and the complexity of the node interactions upon errors. In order to measure the mean time to bus-off(MTTB) of all the nodes, a novel data driven node bus-off time assessment method for CAN network is proposed by directly using network error information. First, the corresponding network error event sequence for each node is constructed using multiple-layer network error information. Then, the generalized zero inflated Poisson process(GZIP) model is established for each node based on the error event sequence. Finally, the stochastic model is constructed to predict the MTTB of the node. The accelerated case studies with different error injection rates are conducted on a laboratory network to demonstrate the proposed method, where the network errors are generated by a computer controlled error injection system. Experiment results show that the MTTB of nodes predicted by the proposed method agree well with observations in the case studies. The proposed data driven node time to bus-off assessment method for CAN networks can successfully predict the MTTB of nodes by directly using network error event data.
Application of redundancy in the Saturn 5 guidance and control system
NASA Technical Reports Server (NTRS)
Moore, F. B.; White, J. B.
1976-01-01
The Saturn launch vehicle's guidance and control system is so complex that the reliability of a simplex system is not adequate to fulfill mission requirements. Thus, to achieve the desired reliability, redundancy encompassing a wide range of types and levels was employed. At one extreme, the lowest level, basic components (resistors, capacitors, relays, etc.) are employed in series, parallel, or quadruplex arrangements to insure continued system operation in the presence of possible failure conditions. At the other extreme, the highest level, complete subsystem duplication is provided so that a backup subsystem can be employed in case the primary system malfunctions. In between these two extremes, many other redundancy schemes and techniques are employed at various levels. Basic redundancy concepts are covered to gain insight into the advantages obtained with various techniques. Points and methods of application of these techniques are included. The theoretical gain in reliability resulting from redundancy is assessed and compared to a simplex system. Problems and limitations encountered in the practical application of redundancy are discussed as well as techniques verifying proper operation of the redundant channels. As background for the redundancy application discussion, a basic description of the guidance and control system is included.