Villamonte-Chevalier, A; van Bree, H; Broeckx, Bjg; Dingemanse, W; Soler, M; Van Ryssen, B; Gielen, I
2015-09-25
Diagnostic imaging is essential to assess the lame patient; lesions of the elbow joint have traditionally been evaluated radiographically, however computed tomography (CT) has been suggested as a useful technique to diagnose various elbow pathologies. The primary objective of this study was to determine the sensitivity and specificity of CT to assess medial coronoid disease (MCD), using arthroscopy as gold standard. The secondary objective was to ascertain the radiographic sensitivity and specificity for MCD compared with CT. For this study 180 elbow joints were assessed, of which 141 had been examined with radiography, CT and arthroscopy; and 39 joints, had radiographic and CT assessment. Sensitivity and specificity were calculated for CT and radiographic findings using available statistical software. Sensitivity and specificity of CT using arthroscopy as gold standard resulted in high values for sensitivity (100 %) and specificity (93 %) for the assessment of MCD. For the radiographic evaluation, a sensitivity of 98 % and specificity of 64 - 69 % using CT as the technique of reference, were found. These results suggest that in case of doubt during radiographic assessment, CT could be used as a non-invasive technique to assess the presence of MCD. Based on the high sensitivity and specificity obtained in this study it has been considered that CT, rather than arthroscopy, is the preferred noninvasive technique to assess MCD lesions of the canine elbow joint.
Williams, Javonda; Nelson-Gardell, Debra; Coulborn Faller, Kathleen; Tishelman, Amy; Cordisco-Steele, Linda
2014-01-01
Using data from a survey of perceptions of 932 child welfare professionals about the utility of extended assessments, the researchers constructed a scale to measure respondents' views about sensitivity (ensuring sexually abused children are correctly identified) and specificity (ensuring nonabused children are correctly identified) in child sexual abuse evaluations. On average, respondents scored high (valuing sensitivity) on the sensitivity versus specificity scale. Next, the researchers undertook bivariate analyses to identify independent variables significantly associated with the sensitivity versus specificity scale. Then those variables were entered into a multiple regression. Four independent variables were significantly related to higher sensitivity scores: encountering cases requiring extended assessments, valuing extended assessments among scarce resources, less concern about proving cases in court, and viewing the goal of extended assessments as understanding needs of child and family (adjusted R2 = .34).
Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Sugimura, Kazuro
2014-03-01
The purpose of this article is to prospectively and directly compare the capabilities of non-contrast-enhanced MR angiography (MRA), 4D contrast-enhanced MRA, and contrast-enhanced MDCT for assessing pulmonary vasculature in patients with non-small cell lung cancer (NSCLC) before surgical treatment. A total of 77 consecutive patients (41 men and 36 women; mean age, 71 years) with pathologically proven and clinically assessed stage I NSCLC underwent thin-section contrast-enhanced MDCT, non-contrast-enhanced and contrast-enhanced MRA, and surgical treatment. The capability for anomaly assessment of the three methods was independently evaluated by two reviewers using a 5-point visual scoring system, and final assessment for each patient was made by consensus of the two readers. Interobserver agreement for pulmonary arterial and venous assessment was evaluated with the kappa statistic. Then, sensitivity, specificity, and accuracy for the detection of anomalies were directly compared among the three methods by use of the McNemar test. Interobserver agreement for pulmonary artery and vein assessment was substantial or almost perfect (κ=0.72-0.86). For pulmonary arterial and venous variation assessment, there were no significant differences in sensitivity, specificity, and accuracy among non-contrast-enhanced MRA (pulmonary arteries: sensitivity, 77.1%; specificity, 97.4%; accuracy, 87.7%; pulmonary veins: sensitivity, 50%; specificity, 98.5%; accuracy, 93.2%), 4D contrast-enhanced MRA (pulmonary arteries: sensitivity, 77.1%; specificity, 97.4%; accuracy, 87.7%; pulmonary veins: sensitivity, 62.5%; specificity, 100.0%; accuracy, 95.9%), and thin-section contrast-enhanced MDCT (pulmonary arteries: sensitivity, 91.4%; specificity, 89.5%; accuracy, 90.4%; pulmonary veins: sensitivity, 50%; specificity, 100.0%; accuracy, 95.9%) (p>0.05). Pulmonary vascular assessment of patients with NSCLC before surgical resection by non-contrast-enhanced MRA can be considered equivalent to that by 4D contrast-enhanced MRA and contrast-enhanced MDCT.
Cartoni, A; Lincoln, N B
2005-03-01
The aim of the study was to assess the sensitivity and specificity of the MEAMS (Golding, 1989) for detecting cognitive impairment after stroke. Stroke patients admitted to hospital received a cognitive screening assessment, the MEAMS, and a detailed cognitive assessment. The information obtained from the detailed assessment was summarised in a structured written report. From the conclusions in these reports, patients were classified as "impaired" or "not impaired" in perception, memory, executive function and language. The sensitivity and specificity of the MEAMS subtests and the overall number of tests passed were determined in relation to the presence of impairment, as given in the overall conclusion of the written reports. There were 30 stroke patients, aged 58 to 92 (mean 75.80, SD 7.94) years. Of these, 17 were men and 13 were women. The sensitivity of the MEAMS subtests ranged from 11% to 100% and the specificity ranged from 69% to 100%. The sensitivity of the overall MEAMS score was 52% and the specificity was 100%, using a cut-off score of 3 or more fails to indicate impairment. Three subtests, Orientation, Naming and Unusual views had 81% sensitivity and 50% specificity for detecting problems in language, perception or memory. The MEAMS was not a sensitive screen for overall cognitive impairment or for memory, perceptual, language, or executive function problems after stroke, but it was specific. Although screening for cognitive impairment is important, the MEAMS is not recommended as the sole method, as it produces an unacceptably high false negative rate. Three subtests (Orientation, Naming and Unusual views) had 81% sensitivity and 50% specificity for detecting cognitive problems in language, perception or memory after stroke.
Sensitivity and specificity of FTDC criteria for behavioral variant frontotemporal dementia.
Harris, Jennifer M; Gall, Claire; Thompson, Jennifer C; Richardson, Anna M T; Neary, David; du Plessis, Daniel; Pal, Piyali; Mann, David M A; Snowden, Julie S; Jones, Matthew
2013-05-14
We aimed to assess sensitivity and specificity of the updated criteria for behavioral variant frontotemporal dementia (bvFTD) based on a large autopsy-confirmed cohort of patients with dementia. Two hundred thirty-nine consecutive pathologically confirmed dementia patients, clinically assessed in a specialist cognitive unit were identified. Patients with predominant aphasia, motor disorders, or insufficient clinical information were excluded. Frontotemporal Dementia Consensus criteria were applied to anonymized clinical data taken from patients' initial assessment by raters who were blinded to clinical and pathologic diagnosis. The final study cohort comprised 156 patients with predominantly early-onset dementia. The updated criteria for possible bvFTD had a sensitivity of 95% and specificity of 82%. Probable bvFTD criteria had a sensitivity of 85% and specificity of 95%. False positives were predominantly patients with presenile Alzheimer disease. Revised diagnostic criteria show encouragingly high sensitivity and specificity when applied to patients with early-onset dementia. They therefore provide a useful tool both for specialist researchers and general clinicians. There is a need for further prospective studies of sensitivity and specificity involving a broader spectrum of patients with dementia.
Teel, Elizabeth; Gay, Michael; Johnson, Brian; Slobounov, Semyon
2016-05-01
Computer-based neuropsychological (NP) evaluation is an effective clinical tool used to assess cognitive function which complements the clinical diagnosis of a concussion. However, some researchers and clinicians argue its lack of ecological validity places limitations on externalizing results to a sensory rich athletic environment. Virtual reality-based NP assessment offers clinical advantages using an immersive environment and evaluating domains not typically assessed by traditional NP assessments. The sensitivity and specificity of detecting lingering cognitive abnormalities was examined on components of a virtual reality-based NP assessment battery to cohort affiliation (concussed vs. controls). Data were retrospectively gathered on 128 controls (no concussion) and 24 concussed college-age athletes on measures of spatial navigation, whole body reaction, attention, and balance in a virtual environment. Concussed athletes were tested within 10 days (M = 8.33, SD = 1.06) of concussion and were clinically asymptomatic at the time of testing. A priori alpha level was set at 0.05 for all tests. Spatial navigation (sensitivity 95.8%/specificity 91.4%, d = 1.89), whole body reaction time (sensitivity 95.2%/specificity 89.1%, d = 1.50) and combined virtual reality modules (sensitivity 95.8%,/specificity 96.1%, d = 3.59) produced high sensitivity/specificity values when determining performance-based variability between groups. Use of a virtual reality-based NP platform can detect lingering cognitive abnormalities resulting from concussion in clinically asymptomatic participants. Virtual reality NP platforms may compliment the traditional concussion assessment battery by providing novel information. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Antón, Alfonso; Pazos, Marta; Martín, Belén; Navero, José Manuel; Ayala, Miriam Eleonora; Castany, Marta; Martínez, Patricia; Bardavío, Javier
2013-01-01
To assess sensitivity, specificity, and agreement among automated event analysis, automated trend analysis, and expert evaluation to detect glaucoma progression. This was a prospective study that included 37 eyes with a follow-up of 36 months. All had glaucomatous disks and fields and performed reliable visual fields every 6 months. Each series of fields was assessed with 3 different methods: subjective assessment by 2 independent teams of glaucoma experts, glaucoma/guided progression analysis (GPA) event analysis, and GPA (visual field index-based) trend analysis. Kappa agreement coefficient between methods and sensitivity and specificity for each method using expert opinion as gold standard were calculated. The incidence of glaucoma progression was 16% to 18% in 3 years but only 3 cases showed progression with all 3 methods. Kappa agreement coefficient was high (k=0.82) between subjective expert assessment and GPA event analysis, and only moderate between these two and GPA trend analysis (k=0.57). Sensitivity and specificity for GPA event and GPA trend analysis were 71% and 96%, and 57% and 93%, respectively. The 3 methods detected similar numbers of progressing cases. The GPA event analysis and expert subjective assessment showed high agreement between them and moderate agreement with GPA trend analysis. In a period of 3 years, both methods of GPA analysis offered high specificity, event analysis showed 83% sensitivity, and trend analysis had a 66% sensitivity.
Teel, Elizabeth F; Gay, Michael R; Arnett, Peter A; Slobounov, Semyon M
2016-03-01
Balance assessments are part of the recommended clinical concussion evaluation, along with computerized neuropsychological testing and self-reported symptoms checklists. New technology has allowed for the creation of virtual reality (VR) balance assessments to be used in concussion care, but there is little information on the sensitivity and specificity of these evaluations. The purpose of this study is to establish the sensitivity and specificity of a VR balance module for detecting lingering balance deficits clinical concussion care. Retrospective case-control study. Institutional research laboratory. Normal controls (n = 94) and concussed participants (n = 27). All participants completed a VR balance assessment paradigm. Concussed participants were diagnosed by a Certified Athletic Trainer or physician (with 48 hours postinjury) and tested in the laboratory between 7 and 10 days postinjury. Receiver operating characteristic curves were performed to establish the VR module's sensitivity and specificity for detecting lingering balance deficits. Final balance score. For the VR balance module, a cutoff score of 8.25 was established to maximize sensitivity at 85.7% and specificity at 87.8%. The VR balance module has high sensitivity and specificity for detecting subacute balance deficits after concussive injury. The VR balance has a high subacute sensitivity and specificity as a stand-alone balance assessment tool and may detect ongoing balance deficits not readily detectable by the Balance Error Scoring System or Sensory Organization Test. Virtual reality balance modules may be a beneficial addition to the current clinical concussion diagnostic battery.
Nishimura, Katsuji; Yokoyama, Kanako; Yamauchi, Noriko; Koizumi, Masako; Harasawa, Nozomi; Yasuda, Taeko; Mimura, Chizuru; Igita, Hazuki; Suzuki, Eriko; Uchiide, Yoko; Seino, Yusuke; Nomura, Minoru; Yamazaki, Kenji; Ishigooka, Jun
2016-01-01
To compare the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium. These tools have not been tested in a specialized cardio-surgical ICU. Sensitivities and specificities of each tool were assessed in a cardio-surgical ICU in Japan by two trained nurses independently. Results were compared with delirium diagnosed by psychiatrists using the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition, Text Revision. There were 110 daily, paired assessments in 31 patients. The CAM-ICU showed 38% sensitivity and 100% specificity for both nurses. All 20 false-negative cases resulted from high scores in the auditory attention screening in CAM-ICU. The ICDSC showed 97% and 94% sensitivity, and 97% and 91% specificity for the two nurses (cutoff ≥4). In a Japanese cardio-surgical ICU, the ICDSC had a higher sensitivity than the CAM-ICU. Copyright © 2016 Elsevier Inc. All rights reserved.
Pinto-Grau, Marta; Burke, Tom; Lonergan, Katie; McHugh, Caroline; Mays, Iain; Madden, Caoifa; Vajda, Alice; Heverin, Mark; Elamin, Marwa; Hardiman, Orla; Pender, Niall
2017-02-01
Cognitive and behavioural changes are an important aspect in Amyotrophic Lateral Sclerosis (ALS). The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) briefly assesses these changes in ALS. To validate the ECAS against a standardised neuropsychological battery and assess its sensitivity and specificity using age and education adjusted cut-off scores. 30 incident ALS cases were assessed on both, ECAS and neuropsychological battery. Age and education adjusted cut-off scores were created from a sample of 82 healthy controls. ECAS composite scores (Total, ALS Specific and Non-Specific) were highly correlated with battery composite scores. High correlations were also observed between ECAS and full battery cognitive domains and subtests. The ECAS Total, ALS Specific and Non-Specific scores were highly sensitive to cognitive impairment. ECAS ALS-Specific cognitive domains also evidenced high sensitivity. Individual subtest sensitivity was medium to low, suggesting that caution should be used when interpreting these scores. Low positive predictive values indicated the presence of false positives. Psychometric properties of the ECAS using age and education adjusted norms indicate that the ECAS, when used as an overall measure of cognitive decline, is highly sensitive. Further comprehensive assessment is required for patients that present as impaired on the ECAS.
Nambi, S Gopal
2013-01-01
The most common instruments developed to assess the functional status of patients with Non specific low back pain is the Roland-Morris Disability Questionnaire (RMDQ). Clinical and epidemiological research related to low back pain in the Gujarati population would be facilitated by the availability of well-established outcome measures. To find the reliability, validity, sensitivity and specificity of the Gujarati version of the RMDQ for use in Non Specific Chronic low back pain. A reliability, validity, sensitivity and specificity study of Gujarati version of the Roland-Morris Disability Questionnaire (RMDQ). Thirty out patients with Non Specific Chronic low back pain were assessed by the RMDQ. Reliability is assessed by using internal consistency and the intra-class correlation coefficient (ICC). Internal construct validity is assessed by RASCH Analysis and external construct validity is assessed by association with pain and spinal movement. Clinical calculator was used to determine the sensitivity and specificity. Internal consistency of the RMDQ is found to be adequate (> 0.65) at both times, with high ICC's also at both time points. Internal construct validity of the scale is good, indicating a single underlying construct. Expected associations with pain and spinal movement confirm external construct validity. The Sensitivity and Specificity at cut off point of 0.5 was 80% and 84% with respectively positive predictive value (PPV) of 83.33% and negative predictive value (NPV) of 80.76%. The Questionnaire is at the ordinal level. The RMDQ is a one-dimensional, ordinal measure, which works well in the Gujarati population.
Rofes, L; Arreola, V; Mukherjee, R; Clavé, P
2014-09-01
Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. © 2014 The Authors. Neurogastroenterology & Motility published by John Wiley & Sons Ltd.
Rofes, L; Arreola, V; Mukherjee, R; Clavé, P
2014-01-01
Background Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. Methods We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. Key Results According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Conclusions & Inferences Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. PMID:24909661
Henry, Stephen G; Feng, Bo; Franks, Peter; Bell, Robert A; Tancredi, Daniel J; Gottfeld, Dustin; Kravitz, Richard L
2014-10-01
To advance research on depression communication and treatment by comparing assessments of communication about depression from patient report, clinician report, and chart review to assessments from transcripts. One hundred sixty-four primary care visits from seven health care systems (2010-2011). Presence or absence of discussion about depressive symptoms, treatment recommendations, and follow-up was measured using patient and clinician postvisit questionnaires, chart review, and coding of audio transcripts. Sensitivity and specificity of indirect measures compared to transcripts were calculated. Patient report was sensitive for mood (83 percent) and sleep (83 percent) but not suicide (55 percent). Patient report was specific for suicide (86 percent) but not for other symptoms (44-75 percent). Clinician report was sensitive for all symptoms (83-98 percent) and specific for sleep, memory, and suicide (80-87 percent), but not for other symptoms (45-48 percent). Chart review was not sensitive for symptoms (50-73 percent), but it was specific for sleep, memory, and suicide (88-96 percent). All indirect measures had low sensitivity for treatment recommendations (patient report: 24-42 percent, clinician report 38-50 percent, chart review 49-67 percent) but high specificity (89-96 percent). For definite follow-up plans, all three indirect measures were sensitive (82-96 percent) but not specific (40-57 percent). Clinician report and chart review generally had the most favorable sensitivity and specificity for measuring discussion of depressive symptoms and treatment recommendations, respectively. © Health Research and Educational Trust.
Suh, Chong Hyun; Yun, Seong Jong; Jin, Wook; Lee, Sun Hwa; Park, So Young; Ryu, Chang-Woo
2018-07-01
To assess the sensitivity and specificity of quantitative assessment of the apparent diffusion coefficient (ADC) for differentiating benign and malignant vertebral bone marrow lesions (BMLs) and compression fractures (CFs) METHODS: An electronic literature search of MEDLINE and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver operating characteristic modelling were performed to evaluate the diagnostic performance of ADC for differentiating vertebral BMLs. Subgroup analysis was performed for differentiating benign and malignant vertebral CFs. Meta-regression analyses according to subject, study and diffusion-weighted imaging (DWI) characteristics were performed. Twelve eligible studies (748 lesions, 661 patients) were included. The ADC exhibited a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.80-0.94) and a pooled specificity of 0.87 (95% CI 0.78-0.93) for differentiating benign and malignant vertebral BMLs. In addition, the pooled sensitivity and specificity for differentiating benign and malignant CFs were 0.92 (95% CI 0.82-0.97) and 0.91 (95% CI 0.87-0.94), respectively. In the meta-regression analysis, the DWI slice thickness was a significant factor affecting heterogeneity (p < 0.01); thinner slice thickness (< 5 mm) showed higher specificity (95%) than thicker slice thickness (81%). Quantitative assessment of ADC is a useful diagnostic tool for differentiating benign and malignant vertebral BMLs and CFs. • Quantitative assessment of ADC is useful in differentiating vertebral BMLs. • Quantitative ADC assessment for BMLs had sensitivity of 89%, specificity of 87%. • Quantitative ADC assessment for CFs had sensitivity of 92%, specificity of 91%. • The specificity is highest (95%) with thinner (< 5 mm) DWI slice thickness.
Validation of time to task performance assessment method in simulation: A comparative design study.
Shinnick, Mary Ann; Woo, Mary A
2018-05-01
There is a lack of objective and valid measures for assessing nursing clinical competence which could adversely impact patient safety. Therefore, we evaluated an objective assessment of clinical competence, Time to Task (ability to perform specific, critical nursing care activities within 5 min), and compared it to two subjective measures, (Lasater Clinical Judgement Rubric [LCJR] and common "pass/fail" assessment). Using a prospective, "Known Groups" (Expert vs. Novice nurses) comparative design, Expert nurses (ICU nurses with >5 years of ICU experience) and Novice nurses (senior prelicensure nursing students) participated individually in a simulation of a patient in decompensated heart failure. Fourteen nursing instructors or preceptors, blinded to group assignment, reviewed 28 simulation videos (15 Expert and 13 Novice) and scored them using the LCJR and pass/fail assessments. Time to Task assessment was scored based on time thresholds for specific nursing actions prospectively set by an expert clinical panel. Statistical analysis consisted of Medians Test and sensitivity and specificity analyses. The LCJR total score was significantly different between Experts and Novices (p < 0.01) and revealed adequate sensitivity (ability to correctly identify "Expert" nurses; 0.72) but had a low specificity (ability to correctly identify "Novice" nurses; 0.40). For the subjective measure 'pass/fail', sensitivity was high (0.90) but specificity was low (0.47). The Time to Task measure had statistical significance between Expert and Novice groups (p < 0.01) and sensitivity (0.80) and specificity (0.85) were good. Commonly used subjective measures of clinical nursing competence have difficulties with achieving acceptable specificity. However, an objective measure, Time to Task, had good sensitivity and specificity in differentiating between groups. While more than one assessment instrument should be used to determine nurse competency, an objective measure, such as Time to Task, warrants further study. Copyright © 2018 Elsevier Ltd. All rights reserved.
Thompson, Aaron; House, Ron; Manno, Michael
2008-05-01
Finger plethysmography and thermometry are objective measures used to assess the vascular aspect of hand-arm vibration syndrome (HAVS). Research to date shows poor correlation between these tests and Stockholm Workshop Scale (SWS) vascular stage. Clinicians, researchers and compensation boards require objective means to diagnose and quantify HAVS. To define the specificity and sensitivity of thermometry and plethysmography using the SWS as the reference criterion. A secondary goal was to consider cut points for the tests optimizing sensitivity and specificity. A cross-sectional analysis was conducted on HAVS patients seen at an occupational medicine specialty clinic. Plethysmography and thermometry were analyzed using SWS vascular stage as the outcome variable. Logistic regression controlled for age, smoking and time since last vibration exposure and use of vasoactive medications. The sensitivity and specificity of the combined tests were calculated using varying cut points. A total of 139 patients consented to participate in the study. Plethysmography stage 1 or greater showed the highest sensitivity (sensitivity 94% and specificity 15%). Specificity was optimized combining plethysmography stage 3 and thermometry stage 3 (specificity 98% and sensitivity 23%). Maximal diagnostic accuracy was achieved by plethysmography alone setting the criteria for a positive test as being stage 1 or greater (70%). Neither plethysmography nor thermometry either alone or in combination demonstrated sufficient sensitivity and specificity to serve as an objective correlate for SWS vascular stage. All combinations of plethysmography and thermometry showed a lower specificity than sensitivity indicating that the SWS may be less sensitive in detecting vascular pathology than the objective tests.
Teel, Elizabeth F; Gay, Michael R; Arnett, Peter A; Slobounov, Semyon M
2015-01-01
Objective Balance assessments are part of the recommended clinical concussion evaluation, along with computerized neuropsychological testing and self-reported symptoms checklists. New technology has allowed for the creation of virtual reality (VR) balance assessments to be used in concussion care, but there is little information on the sensitivity and specificity of these evaluations. The purpose of this study is to establish the sensitivity and specificity of a VR balance module for detecting lingering balance deficits clinical concussion care. Design Retrospective, case-control study Setting Institutional research laboratory Participants Normal controls (n=94) and concussed participants (n=27) Interventions All participants completed a VR balance assessment paradigm. Concussed participants were diagnosed by a Certified Athletic Trainer or physician (with 48 hours post-injury) and tested in the lab between 7-10 days post-injury. ROC curves were performed in order to establish the VR module’s sensitivity and specificity for detecting lingering balance deficits. Main Outcome Measures Final balance score Results For the VR balance module, a cutoff score of 8.25 was established to maximize sensitivity at 85.7% and specificity at 87.8%. Conclusions The VR balance module has high sensitivity and specificity for detecting sub-acute balance deficits after concussive injury. PMID:26505696
ERIC Educational Resources Information Center
Laurenceau, Jean-Philippe; Kleinman, Brighid M.; Kaczynski, Karen J.; Carver, Charles S.
2010-01-01
Self-report scales assessing relationship-specific incentive and threat sensitivity were created. Initial tests of factor structure and associations with relationship quality were conducted in a sample of persons in intimate relationships (Study 1). Associations with conceptually related measures were examined to determine convergent and…
Lovallo, Carmela; Rolandi, Stefano; Rossetti, Anna Maria; Lusignani, Maura
2010-03-01
This paper is a report of a study comparing the effectiveness of two falls risk assessment tools (Conley Scale and Hendrich Risk Model) by using them simultaneously with the same sample of hospital inpatients. Different risk assessment tools are available in literature. However, neither recent critical reviews nor international guidelines on fall prevention have identified tools that can be generalized to all categories of hospitalized patients. A prospective observational study was carried out in acute medical, surgical wards and rehabilitation units. From October 2007 to January 2008, 1148 patients were assessed with both instruments, subsequently noting the occurrence of falls. The sensitivity, specificity, positive and negative predictive values, and Receiver Operating Characteristics curves were calculated. The number of patients correctly identified with the Conley Scale (n = 41) was higher than with the Hendrich Model (n = 27). The Conley Scale gave sensitivity and specificity values of 69.49% and 61% respectively. The Hendrich Model gave a sensitivity value of 45.76% and a specificity value of 71%. Positive and negative predictive values were comparable. The Conley Scale is indicated for use in the medical sector, on the strength of its high sensitivity. However, since its specificity is very low, it is deemed useful to submit individual patients giving positive results to more in-depth clinical evaluation in order to decide whether preventive measures need to be taken. In surgical sectors, the low sensitivity values given by both scales suggest that further studies are warranted.
Mallorie, Amy; Goldring, James; Patel, Anant; Lim, Eric; Wagner, Thomas
2017-08-01
Lymph node involvement in non-small-cell lung cancer (NSCLC) is a major factor in determining management and prognosis. We aimed to evaluate the accuracy of fluorine-18-fluorodeoxyglucose-PET/computed tomography (CT) for the assessment of nodal involvement in patients with NSCLC. In this retrospective study, we included 61 patients with suspected or confirmed resectable NSCLC over a 2-year period from April 2013 to April 2015. 221 nodes with pathological staging from surgery or endobronchial ultrasound-guided transbronchial needle aspiration were assessed using a nodal station-based analysis with original clinical reports and three different cut-offs: mediastinal blood pool (MBP), liver background and tumour standardized uptake value maximal (SUVmax)/2. Using nodal station-based analysis for activity more than tumour SUVmax/2, the sensitivity was 45%, the specificity was 89% and the negative predictive value (NPV) was 87%. For activity more than MBP, the sensitivity was 93%, the specificity was 72% and NPV was 98%. For activity more than liver background, the sensitivity was 83%, the specificity was 84% and NPV was 96%. Using a nodal staging-based analysis for accuracy at detecting N2/3 disease, for activity more than tumour SUVmax/2, the sensitivity was 59%, the specificity was 85% and NPV was 80%. For activity more than MBP, the sensitivity was 95%, the specificity was 61% and NPV was 96%. For activity more than liver background, the sensitivity was 86%, the specificity was 81% and NPV was 92%. Receiver-operating characteristic analysis showed the optimal nodal SUVmax to be more than 6.4 with a sensitivity of 45% and a specificity of 95%, with an area under the curve of 0.85. Activity more than MBP was the most sensitive cut-off with the highest sensitivity and NPV. Activity more than primary tumour SUVmax/2 was the most specific cut-off. Nodal SUVmax more than 6.4 has a high specificity of 95%.
A New Method for Assessing How Sensitivity and Specificity of Linkage Studies Affects Estimation
Moore, Cecilia L.; Amin, Janaki; Gidding, Heather F.; Law, Matthew G.
2014-01-01
Background While the importance of record linkage is widely recognised, few studies have attempted to quantify how linkage errors may have impacted on their own findings and outcomes. Even where authors of linkage studies have attempted to estimate sensitivity and specificity based on subjects with known status, the effects of false negatives and positives on event rates and estimates of effect are not often described. Methods We present quantification of the effect of sensitivity and specificity of the linkage process on event rates and incidence, as well as the resultant effect on relative risks. Formulae to estimate the true number of events and estimated relative risk adjusted for given linkage sensitivity and specificity are then derived and applied to data from a prisoner mortality study. The implications of false positive and false negative matches are also discussed. Discussion Comparisons of the effect of sensitivity and specificity on incidence and relative risks indicate that it is more important for linkages to be highly specific than sensitive, particularly if true incidence rates are low. We would recommend that, where possible, some quantitative estimates of the sensitivity and specificity of the linkage process be performed, allowing the effect of these quantities on observed results to be assessed. PMID:25068293
Sensitivity and specificity of mammographic screening as practised in Vermont and Norway
Hofvind, S; Geller, B M; Skelly, J; Vacek, P M
2012-01-01
Objective The aim of this study was to examine the sensitivity and specificity of screening mammography as performed in Vermont, USA, and Norway. Methods Incident screening data from 1997 to 2003 for female patients aged 50–69 years from the Vermont Breast Cancer Surveillance System (116 996 subsequent screening examinations) and the Norwegian Breast Cancer Screening Program (360 872 subsequent screening examinations) were compared. Sensitivity and specificity estimates for the initial (based on screening mammogram only) and final (screening mammogram plus any further diagnostic imaging) interpretations were directly adjusted for age using 5-year age intervals for the combined Vermont and Norway population, and computed for 1 and 2 years of follow-up, which ended at the time of the next screening mammogram. Results For the 1-year follow-up, sensitivities for initial assessments were 82.0%, 88.2% and 92.5% for 1-, 2- and >2-year screening intervals, respectively, in Vermont (p=0.022). For final assessments, the values were 73.6%, 83.3% and 81.2% (p=0.047), respectively. For Norway, sensitivities for initial assessments were 91.0% and 91.3% (p=0.529) for 2- and >2-year intervals, and 90.7% and 91.3%, respectively, for final assessments (p=0.630). Specificity was lower in Vermont than in Norway for each screening interval and for all screening intervals combined, for both initial (90.6% vs 97.8% for all intervals; p<0.001) and final (98.8% vs 99.5% for all intervals; p<0.001) assessments. Conclusion Our study showed higher sensitivity and specificity in a biennial screening programme with an independent double reading than in a predominantly annual screening program with a single reading. Advances in knowledge This study demonstrates that higher recall rates and lower specificity are not always associated with higher sensitivity of screening mammography. Differences in the screening processes in Norway and Vermont suggest potential areas for improvement in the latter. PMID:22993383
Edwards, D. L.; Saleh, A. A.; Greenspan, S. L.
2015-01-01
Summary We performed a systematic review and meta-analysis of the performance of clinical risk assessment instruments for screening for DXA-determined osteoporosis or low bone density. Commonly evaluated risk instruments showed high sensitivity approaching or exceeding 90 % at particular thresholds within various populations but low specificity at thresholds required for high sensitivity. Simpler instruments, such as OST, generally performed as well as or better than more complex instruments. Introduction The purpose of the study is to systematically review the performance of clinical risk assessment instruments for screening for dual-energy X-ray absorptiometry (DXA)-determined osteoporosis or low bone density. Methods Systematic review and meta-analysis were performed. Multiple literature sources were searched, and data extracted and analyzed from included references. Results One hundred eight references met inclusion criteria. Studies assessed many instruments in 34 countries, most commonly the Osteoporosis Self-Assessment Tool (OST), the Simple Calculated Osteoporosis Risk Estimation (SCORE) instrument, the Osteoporosis Self-Assessment Tool for Asians (OSTA), the Osteoporosis Risk Assessment Instrument (ORAI), and body weight criteria. Meta-analyses of studies evaluating OST using a cutoff threshold of <1 to identify US postmenopausal women with osteoporosis at the femoral neck provided summary sensitivity and specificity estimates of 89 % (95%CI 82–96 %) and 41 % (95%CI 23–59 %), respectively. Meta-analyses of studies evaluating OST using a cutoff threshold of 3 to identify US men with osteoporosis at the femoral neck, total hip, or lumbar spine provided summary sensitivity and specificity estimates of 88 % (95%CI 79–97 %) and 55 % (95%CI 42–68 %), respectively. Frequently evaluated instruments each had thresholds and populations for which sensitivity for osteoporosis or low bone mass detection approached or exceeded 90 % but always with a trade-off of relatively low specificity. Conclusions Commonly evaluated clinical risk assessment instruments each showed high sensitivity approaching or exceeding 90 % for identifying individuals with DXA-determined osteoporosis or low BMD at certain thresholds in different populations but low specificity at thresholds required for high sensitivity. Simpler instruments, such as OST, generally performed as well as or better than more complex instruments. PMID:25644147
Exhaled molecular profiles in the assessment of cystic fibrosis and primary ciliary dyskinesia.
Paff, T; van der Schee, M P; Daniels, J M A; Pals, G; Postmus, P E; Sterk, P J; Haarman, E G
2013-09-01
Early diagnosis and monitoring of disease activity are essential in cystic fibrosis (CF) and primary ciliary dyskinesia (PCD). We aimed to establish exhaled molecular profiles as the first step in assessing the potential of breath analysis. Exhaled breath was analyzed by electronic nose in 25 children with CF, 25 with PCD and 23 controls. Principle component reduction and canonical discriminant analysis were used to construct internally cross-validated ROC curves. CF and PCD patients had significantly different breath profiles when compared to healthy controls (CF: sensitivity 84%, specificity 65%; PCD: sensitivity 88%, specificity 52%) and from each other (sensitivity 84%, specificity 60%). Patients with and without exacerbations had significantly different breath profiles (CF: sensitivity 89%, specificity 56%; PCD: sensitivity 100%, specificity 90%). Exhaled molecular profiles significantly differ between patients with CF, PCD and controls. The eNose may have potential in disease monitoring based on the influence of exacerbations on the VOC-profile. Copyright © 2012 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
A Performance Comparison of Color Vision Tests for Military Screening.
Walsh, David V; Robinson, James; Jurek, Gina M; Capó-Aponte, José E; Riggs, Daniel W; Temme, Leonard A
2016-04-01
Current color vision (CV) tests used for aviation screening in the U.S. Army only provide pass-fail results, and previous studies have shown variable sensitivity and specificity. The purpose of this study was to evaluate seven CV tests to determine an optimal CV test screener that potentially could be implemented by the U.S. Army. There were 133 subjects [65 Color Vision Deficits (CVD), 68 Color Vision Normal (CVN)] who performed all of the tests in one setting. CVD and CVN determination was initially assessed with the Oculus anomaloscope. Each test was administered monocularly and according to the test protocol. The main outcome measures were test sensitivity, specificity, and administration time (automated tests). Three of the four Pseudoisochromatic Plate (PIP) tests had a sensitivity/specificity > 0.90 OD/OS, whereas the FALANT tests had a sensitivity/specificity > 0.80 OD/OS. The Cone Contrast Test (CCT) demonstrated sensitivity/specificity > 0.90 OD/OS, whereas the Color Assessment and Diagnosis (CAD) test demonstrated sensitivity/specificity > 0.85 OD/OS. Comparison with the anomaloscope ("gold standard") revealed no significant difference of sensitivity and specificity OD/OS with the CCT, Dvorine PIP, and PIPC tests. Finally, the CCT administration time was significantly faster than the CAD test. The current U.S. Army CV screening tests demonstrated good sensitivity and specificity, as did the automated tests. In addition, some current PIP tests (Dvorine, PIPC), and the CCT performed no worse statistically than the anomaloscope with regard to sensitivity/specificity. The CCT letter presentation is randomized and results would not be confounded by potential memorization, or fading, of book plates.
Visser, Cobus; Kieser, Eduard; Dellimore, Kiran; van den Heever, Dawie; Smith, Johan
2017-10-01
This study explores the feasibility of prospectively assessing infant dehydration using four non-invasive, optical sensors based on the quantitative and objective measurement of various clinical markers of dehydration. The sensors were investigated to objectively and unobtrusively assess the hydration state of an infant based on the quantification of capillary refill time (CRT), skin recoil time (SRT), skin temperature profile (STP) and skin tissue hydration by means of infrared spectrometry (ISP). To evaluate the performance of the sensors a clinical study was conducted on a cohort of 10 infants (aged 6-36 months) with acute gastroenteritis. High sensitivity and specificity were exhibited by the sensors, in particular the STP and SRT sensors, when combined into a fusion regression model (sensitivity: 0.90, specificity: 0.78). The SRT and STP sensors and the fusion model all outperformed the commonly used "gold standard" clinical dehydration scales including the Gorelick scale (sensitivity: 0.56, specificity: 0.56), CDS scale (sensitivity: 1.0, specificity: 0.2) and WHO scale (sensitivity: 0.13, specificity: 0.79). These results suggest that objective and quantitative assessment of infant dehydration may be possible using the sensors investigated. However, further evaluation of the sensors on a larger sample population is needed before deploying them in a clinical setting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Calabrese, Emma; Maaser, Christian; Zorzi, Francesca; Kannengiesser, Klaus; Hanauer, Stephen B; Bruining, David H; Iacucci, Marietta; Maconi, Giovanni; Novak, Kerri L; Panaccione, Remo; Strobel, Deike; Wilson, Stephanie R; Watanabe, Mamoru; Pallone, Francesco; Ghosh, Subrata
2016-05-01
Bowel ultrasonography (US) is considered a useful technique for assessing mural inflammation and complications in Crohn's disease (CD). The aim of this review is to appraise the evidence on the accuracy of bowel US for CD. In addition, we aim to provide recommendations for its optimal use. Publications were identified by literature search from 1992 to 2014 and selected based on predefined criteria: 15 or more patients; bowel US for diagnosing CD, complications, postoperative recurrence, activity; adequate reference standards; prospective study design; data reported to allow calculation of sensitivity, specificity, agreement, or correlation values; articles published in English. The search yielded 655 articles, of which 63 were found to be eligible and retrieved as full-text articles for analysis. Bowel US showed 79.7% sensitivity and 96.7% specificity for the diagnosis of suspected CD, and 89% sensitivity and 94.3% specificity for initial assessment in established patients with CD. Bowel US identified ileal CD with 92.7% sensitivity, 88.2% specificity, and colon CD with 81.8% sensitivity, 95.3% specificity, with lower accuracy for detecting proximal lesions. The oral contrast agent improves the sensitivity and specificity in determining CD lesions and in assessing sites and extent. Bowel US is a tool for evaluation of CD lesions in terms of complications, postoperative recurrence, and monitoring response to medical therapy; it reliably detects postoperative recurrence and complications, as well as offers the possibility of monitoring disease progression.
Effect of Sport Related Concussion on Clinically Measured Simple Reaction Time
Eckner, James T.; Kutcher, Jeffrey S.; Broglio, Steven P.; Richardson, James K.
2013-01-01
Background Reaction time (RT) is a valuable component of the sport concussion assessment battery. RT is typically measured using computers running specialized software, which limits its applicability in some athletic settings and populations. To address this, we developed a simple clinical test of RT (RTclin) that involves grasping a falling measuring stick. Purpose To determine the effect of concussion on RTclin and its sensitivity and specificity for concussion. Materials and methods Concussed athletes (n=28) and non-concussed control teammates (n=28) completed RTclin assessments at baseline and within 48 hours of injury. Repeated measures ANOVA compared mean baseline and follow-up RTclin values between groups. Sensitivity and specificity were calculated over a range of reliable change confidence levels. Results RTclin differed significantly between groups (p < .001): there was significant prolongation from baseline to post-injury in the concussed group (p= .003), with a trend toward improvement in the control group (p = .058). Sensitivity and specificity were maximized when a critical change value of 0 ms was applied (i.e., any increase in RTclin from baseline was interpreted as abnormal), which corresponded to a sensitivity of 75%, specificity of 68%, and a 65% reliable change confidence level. Conclusions RTclin appears sensitive to the effects of concussion and distinguished concussed and non-concussed athletes with similar sensitivity and specificity to other commonly used concussion assessment tools. Given its simplicity, low cost, and minimal time requirement, RTclin should be considered a viable component of the sports medicine provider’s multifaceted concussion assessment battery. PMID:23314889
Cettomai, Deanna; Kwasa, Judith; Kendi, Caroline; Birbeck, Gretchen L; Price, Richard W; Bukusi, Elizabeth A; Cohen, Craig R; Meyer, Ana-Claire
2010-12-08
Neuropathy is the most common neurologic complication of HIV but is widely under-diagnosed in resource-constrained settings. We aimed to identify tools that accurately distinguish individuals with moderate/severe peripheral neuropathy and can be administered by non-physician healthcare workers (HCW) in resource-constrained settings. We enrolled a convenience sample of 30 HIV-infected outpatients from a Kenyan HIV-care clinic. A HCW administered the Neuropathy Severity Score (NSS), Single Question Neuropathy Screen (Single-QNS), Subjective Peripheral Neuropathy Screen (Subjective-PNS), and Brief Peripheral Neuropathy Screen (Brief-PNS). Monofilament, graduated tuning fork, and two-point discrimination examinations were performed. Tools were validated against a neurologist's clinical assessment of moderate/severe neuropathy. The sample was 57% male, mean age 38.6 years, and mean CD4 count 324 cells/µL. Neurologist's assessment identified 20% (6/30) with moderate/severe neuropathy. Diagnostic utilities for moderate/severe neuropathy were: Single-QNS--83% sensitivity, 71% specificity; Subjective-PNS-total--83% sensitivity, 83% specificity; Subjective-PNS-max and NSS--67% sensitivity, 92% specificity; Brief-PNS--0% sensitivity, 92% specificity; monofilament--100% sensitivity, 88% specificity; graduated tuning fork--83% sensitivity, 88% specificity; two-point discrimination--75% sensitivity, 58% specificity. Pilot testing suggests Single-QNS, Subjective-PNS, and monofilament examination accurately identify HIV-infected patients with moderate/severe neuropathy and may be useful diagnostic tools in resource-constrained settings.
Cognitive Screening in Brain Tumors: Short but Sensitive Enough?
Robinson, Gail A.; Biggs, Vivien; Walker, David G.
2015-01-01
Cognitive deficits in brain tumors are generally thought to be relatively mild and non-specific, although recent evidence challenges this notion. One possibility is that cognitive screening tools are being used to assess cognitive functions but their sensitivity to detect cognitive impairment may be limited. For improved sensitivity to recognize mild and/or focal cognitive deficits in brain tumors, neuropsychological evaluation tailored to detect specific impairments has been thought crucial. This study investigates the sensitivity of a cognitive screening tool, the Montreal Cognitive Assessment (MoCA), compared to a brief but tailored cognitive assessment (CA) for identifying cognitive deficits in an unselected primary brain tumor sample (i.e., low/high-grade gliomas, meningiomas). Performance is compared on broad measures of impairment: (a) number of patients impaired on the global screening measure or in any cognitive domain; and (b) number of cognitive domains impaired and specific analyses of MoCA-Intact and MoCA-Impaired patients on specific cognitive tests. The MoCA-Impaired group obtained lower naming and word fluency scores than the MoCA-Intact group, but otherwise performed comparably on cognitive tests. Overall, based on our results from patients with brain tumor, the MoCA has extremely poor sensitivity for detecting cognitive impairments and a brief but tailored CA is necessary. These findings will be discussed in relation to broader issues for clinical management and planning, as well as specific considerations for neuropsychological assessment of brain tumor patients. PMID:25815273
Li, Jialin; Lowres, Nicole; Jin, Kai; Zhang, Ling; Neubeck, Lis; Gallagher, Robyn
Chinese immigrants are at an increased risk for cardiovascular diseases (CVDs) compared with Chinese nationals partly because of lifestyle changes and knowledge deficits. Translated patient resources are available on the Internet and are often provided by health professionals; however, the quality and cultural sensitivity of these resources have not been reported. The aim of this study was to assess the availability, quality, and cultural sensitivity of Chinese-language information available from national "Heart Foundations" (cardiac research bodies, nongovernmental organisations) of the 5 most popular destinations of Chinese immigration. This study is a descriptive research in which national "Heart Foundation" websites were systematically searched for Chinese-language CVD patient education resources. Quality (content, identification, structure) was assessed using the Ensuring Quality Information for Patients instrument. Cultural sensitivity was evaluated using the Cultural Sensitivity Assessment Tool. From 107 identified resources, 33 were CVD specific: coronary heart disease (n = 20), arrhythmias (n = 7), and heart failure (n = 6). Quality of resources was adequate (mean Ensuring Quality Information for Patients score, 69%), but scores varied significantly (min, 60%; max, 85%). Although all resources were classified as culturally sensitive (Cultural Sensitivity Assessment Tool score ≥ 2.5), 2 resources scored low (≤2.5) for visual impact, and across all resources, written and visual domains were assessed as least culturally sensitive. Most resources lacked culturally specific references. Chinese-language CVD resources were inconsistent in the supply of key information. Quality and level of cultural sensitivity were adequate, but most resources lacked culturally specific references. Comprehensive, high-quality CVD resources powered by Editorial Manager and ProduXion Manager from Aries Systems Corporation tailored for Chinese immigrants are urgently needed for healthcare providers to support CVD education and care of patients belonging to this population.
Ibrahim, Osama M A; Dogru, Murat; Ward, Samantha K; Matsumoto, Yukihiro; Wakamatsu, Tais Hitomi; Ishida, Katsushi; Tsuyama, Atsushi; Kojima, Takashi; Shimazaki, Jun; Tsubota, Kazuo
2011-04-06
To evaluate the specificity and sensitivity of strip meniscometry (SM) testing in conjunction with tear function tests in the diagnosis of dry eye (DE) disease and to investigate the effect of SM on reflex tearing. One hundred seven left eyes of 107 patients with definite DE disease according to the Japanese DE diagnostic criteria and 68 left eyes of 68 age- and sex-matched control subjects were studied. Tear meniscus height (TMH) measurements, fluorescein tear film break-up time (FTBUT), fluorescein (F) and rose bengal (RB) staining, and Schirmer's test-1 (ST) were also performed. The assessment of reflex tearing before and after SM application was assessed with a graticule scale at the slit lamp and by optical coherence tomography. The sensitivity and specificity of SM alone and in combination with tear function tests were also sought. The SM scores, TMH measurements, FTBUTs, and STs were significantly lower in dry eye patients than in the controls (P < 0.001). The RB and F staining scores were significantly higher in the dry eye group than in the control group (P < 0.001). The meniscometry strips did not induce significant changes in relation to reflex tearing. SM had an acceptable sensitivity and specificity. SM is a swift, noninvasive, promising method of assessing tear meniscus volume. The combined SM and FTBUT examination appears to be a sensitive approach to the assessment of dry eye disease.
Kaszás, B; Kovács, N; Balás, I; Kállai, J; Aschermann, Z; Kerekes, Z; Komoly, S; Nagy, F; Janszky, J; Lucza, T; Karádi, K
2012-06-01
Among the non-motor features of Parkinson's disease (PD), cognitive impairment is one of the most troublesome problems. Highly sensitive and specific screening instruments for detecting dementia in PD (PDD) are required in the clinical practice. In our study we evaluated the sensitivity and specificity of different neuropsychological tests (Addenbrooke's Cognitive Examination, ACE; Frontal Assessment Battery, FAB and Mattis Dementia Rating Scale, MDRS) in 73 Parkinson's disease patients without depression. By receiver operating characteristic curve analysis, these screening instruments were tested against the recently established clinical diagnostic criteria of PDD. Best cut-off score for ACE to identify PDD was 80 points (sensitivity = 74.0%, specificity = 78.1%). For FAB the most optimal cut-off value was 12 points (sensitivity = 66.3%, specificity = 72.2%); whereas for MDRS it was 125 points (sensitivity = 89.8%, specificity = 98.3%). Among the examined test batteries, MDRS had the best clinicometric profile for detecting PDD. Although the types of applied screening instruments might differ from movement disorder clinic to clinic within a country, determination of the most specific and sensitive test for the given population remains to be an important task. Our results demonstrated that the specificity and sensitivity of MDRS was better than those of ACE, FAB and MMSE in Hungary. However, further studies with larger sample size and more uniform criteria for participation are required to determine the most suitable screening instrument for cognitive impairment. Copyright © 2012 Elsevier Ltd. All rights reserved.
Reliable change of the sensory organization test.
Broglio, Steven P; Ferrara, Michael S; Sopiarz, Kay; Kelly, Michael S
2008-03-01
To establish the sensitivity and specificity of the NeuroCom Sensory Organization Test (SOT) and provide practitioners with cut-scores for clinical decision making using estimates of reliable change. Retrospective cohort study. Research laboratory. Healthy (n = 66) and concussed (n = 63) young adult participants. Postural control assessments on the NeuroCom SOT were completed twice (baseline and follow-up) for both groups. Postconcussion assessments were administered within 24 hours of injury diagnosis. The reliable change technique was used to calculated cut-scores for each SOT variable (composite balance; somatosensory, visual, and vestibular ratios) at the 95%, 90%, 85%, 80%, 75%, and 70% confidence interval levels. When cut-scores were applied to the post-concussion evaluations, sensitivity and specificity varied with SOT variable and confidence interval. An evaluation for change on one or more SOT variable resulted in the highest combined sensitivity (57%) and specificity (80%) at the 75% confidence interval. Use of reliable change scores to detect significant changes in performance on the SOT resulted in decreased sensitivity and improved specificity compared to a previous report. These findings indicate that some concussed athletes may not show large changes in postconcussion postural control and this postural control evaluation should not be used in exclusion of other assessment techniques. The postural control assessment should be combined with other evaluative measures to gain the highest sensitivity to concussive injuries.
Levitt, Jacob Oren; Levitt, Barrie H.; Akhavan, Arash; Yanofsky, Howard
2010-01-01
Background. There are relatively few studies published examining the sensitivity and specificity of potassium hydroxide (KOH) smear and fungal culture examination of tinea pedis. Objective. To evaluate the sensitivity and specificity of KOH smear and fungal culture for diagnosing tinea pedis. Methods. A pooled analysis of data from five similarly conducted bioequivalence trials for antifungal drugs was performed. Data from 460 patients enrolled in the vehicle arms of these studies with clinical diagnosis of tinea pedis supported by positive fungal culture were analyzed 6 weeks after initiation of the study to determine the sensitivity and specificity of KOH smear and fungal culture. Results. Using clinical assessment as the gold standard, the sensitivities for KOH smear and culture were 73.3% (95% CI: 66.3 to 79.5%) and 41.7% (34.6 to 49.1%), respectively. The respective specificities for culture and KOH smear were 77.7% (72.2 to 82.5%) and 42.5% (36.6 to 48.6%). Conclusion. KOH smear and fungal culture are complementary diagnostic tests for tinea pedis, with the former being the more sensitive test of the two, and the latter being more specific. PMID:20672004
Chen, Chia-Wei; Chu, Hsin; Tsai, Chia-Fen; Yang, Hui-Ling; Tsai, Jui-Chen; Chung, Min-Huey; Liao, Yuan-Mei; Chi, Mei-Ju; Chou, Kuei-Ru
2015-11-01
The purpose of this study was to translate the Rowland Universal Dementia Assessment Scale into Chinese and to evaluate the psychometric properties (reliability and validity) and the diagnostic properties (sensitivity, specificity and predictive values) of the Chinese version of the Rowland Universal Dementia Assessment Scale. The accurate detection of early dementia requires screening tools with favourable cross-cultural linguistic and appropriate sensitivity, specificity, and predictive values, particularly for Chinese-speaking populations. This was a cross-sectional, descriptive study. Overall, 130 participants suspected to have cognitive impairment were enrolled in the study. A test-retest for determining reliability was scheduled four weeks after the initial test. Content validity was determined by five experts, whereas construct validity was established by using contrasted group technique. The participants' clinical diagnoses were used as the standard in calculating the sensitivity, specificity, positive predictive value and negative predictive value. The study revealed that the Chinese version of the Rowland Universal Dementia Assessment Scale exhibited a test-retest reliability of 0.90, an internal consistency reliability of 0.71, an inter-rater reliability (kappa value) of 0.88 and a content validity index of 0.97. Both the patients and healthy contrast group exhibited significant differences in their cognitive ability. The optimal cut-off points for the Chinese version of the Rowland Universal Dementia Assessment Scale in the test for mild cognitive impairment and dementia were 24 and 22, respectively; moreover, for these two conditions, the sensitivities of the scale were 0.79 and 0.76, the specificities were 0.91 and 0.81, the areas under the curve were 0.85 and 0.78, the positive predictive values were 0.99 and 0.83 and the negative predictive values were 0.96 and 0.91 respectively. The Chinese version of the Rowland Universal Dementia Assessment Scale exhibited sound reliability, validity, sensitivity, specificity and predictive values. This scale can help clinical staff members to quickly and accurately diagnose cognitive impairment and provide appropriate treatment as early as possible. © 2015 John Wiley & Sons Ltd.
Selamat, Rusidah; Zain, Fuziah; Raib, Junidah; Zakaria, Rosini; Marzuki, Mohd Shaffari; Ibrahim, Taziah Fatimah
2011-12-01
To study the validity of the visual clinical assessment of weight relative to length and length relative to age as compared to the World Health Organization (WHO) 2006 standard and National Center for Health Statistics (NCHS) 1977 reference in asssessing the physical growth of children younger than 1 year. A prospective cohort study was carried out among 684 infants attending goverment health clinics in 2 states in Malaysia. Body weight, length, and clinical assessment were measured on the same day for 9 visits, scheduled every month until 6 months of age and every 2 months until 12 months of age. All of the 3 z-scores for weight for age (WAZ), length for age (HAZ), and weight for length (WHZ) were calculated using WHO Anthro for Personal Computers software. The average sensitivity and specificity for the visual clinical assessment for the detection of thinness were higher using the WHO 2006 standard as compared with using NCHS 1977. However, the overall sensitivity of the visual clinical assessment for the detection of thin and lean children was lower from 1 month of age until a year as compared with the WHO 2006 standard and NCHS 1977 reference. The positive predictive value (PPV) for the visual clinical assessment versus the WHO 2006 standard was almost doubled as compared with the PPV of visual clinical assessment versus the NCHS 1977 reference. The overall average sensitivity, specificity, PPV, and negative predictive value for the detection of stunting was higher for visual clinical assessment versus the WHO 2006 standard as compared with visual clinical assessment versus the NCHS 1977 reference. The sensitivity and specificity of visual clinical assessment for the detection of wasting and stunting among infants are better for the WHO 2006 standard than the NCHS 1977 reference.
Kiss, Joseph E.; Steele, Whitney R.; Wright, David J.; Mast, Alan E.; Carey, Patricia M.; Murphy, Edward L.; Gottschall, Jerry L.; Simon, Toby L.; Cable, Ritchard G.
2014-01-01
BACKGROUND Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management. STUDY DESIGN AND METHODS A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study-II (REDS-II) Donor Iron Status Evaluation (RISE) study who were either first-time/reactivated (FT/ RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 µ.g/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron-deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE. RESULTS HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 u.g/L was a good surrogate for assessing IDE. CONCLUSION RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency. PMID:23617531
van Dijken, Bart R J; van Laar, Peter Jan; Holtman, Gea A; van der Hoorn, Anouk
2017-10-01
Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. • Treatment response assessment in high-grade gliomas with anatomical MRI is unreliable • Novel advanced MRI techniques have been studied, but diagnostic accuracy is unknown • Meta-analysis demonstrates that advanced MRI showed higher diagnostic accuracy than anatomical MRI • Highest diagnostic accuracy for spectroscopy and perfusion MRI • Supports the incorporation of advanced MRI in high-grade glioma treatment response assessment.
Kiss, Joseph E; Steele, Whitney R; Wright, David J; Mast, Alan E; Carey, Patricia M; Murphy, Edward L; Gottschall, Jerry L; Simon, Toby L; Cable, Ritchard G
2013-11-01
Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management. A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study-II (REDS-II) Donor Iron Status Evaluation (RISE) study who were either first-time/reactivated (FT/RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 μg/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron-deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE. HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 μg/L was a good surrogate for assessing IDE. RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency. © 2013 American Association of Blood Banks.
Weissberger, Gali H.; Strong, Jessica V.; Stefanidis, Kayla B.; Summers, Mathew J.; Bondi, Mark W.; Stricker, Nikki H.
2018-01-01
With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer’s dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer’s disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers. PMID:28940127
Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.
Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C
2016-06-01
The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.
Kang, Keren; Wu, Peidian; Li, Wenmei; Tang, Shixing; Wang, Jihua; Luo, Xiaochun; Xie, Mingquan
2015-01-01
To develop a rapid, sensitive and specific assay for quantification of serum heart-type fatty acid binding protein (H-FABP) based on immunofluorescence of specific monoclonal antibodies. We generated novel H-FABP-directed monoclonal antibodies by cloning of spleen cells of mice immunized with H-FABP. Epitopes were mapped and antigen affinity was assessed by surface plasmon resonance (SPR). The H-FABP specific monoclonal antibodies were coupled to fluorescent beads and sprayed onto a nitrocellulose membrane facilitating quantification of H-FABP by immunofluorescence. Reagent cross-reactivity, interference resistance, accuracy and sensitivity were examined. A total of 103 clinical samples were used to compare the sensitivity and specificity of the new assay to a commercially available Randox kit. This new assay could be finished within 15 min, with sensitivity reaching 1 ng/ml. In a trial of 103 clinical serum samples, the new testing kit results were highly correlated with those from the Randox kit (R(2) = 0.9707). Using the Randox kit as the reference kit, the sensitivity of the new assay was 98.25%, and specificity was 100%. An immunofluorescence-based H-FABP assay employing novel monoclonal antibodies could rapidly, specifically and sensitively detect H-FABP in serum samples, providing an effective method for rapid clinical assessment of H-FABP index in the clinic.
Ahluwalia, Indu B; Helms, Kristen; Morrow, Brian
2013-01-01
We investigated the reliability and validity of three self-reported indicators from the Pregnancy Risk Assessment Monitoring System (PRAMS) survey. We used 2008 PRAMS (n=15,646) data from 12 states that had implemented the 2003 revised U.S. Certificate of Live Birth. We estimated reliability by kappa coefficient and validity by sensitivity and specificity using the birth certificate data as the reference for the following: prenatal participation in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC); Medicaid payment for delivery; and breastfeeding initiation. These indicators were examined across several demographic subgroups. The reliability was high for all three measures: 0.81 for WIC participation, 0.67 for Medicaid payment of delivery, and 0.72 for breastfeeding initiation. The validity of PRAMS indicators was also high: WIC participation (sensitivity = 90.8%, specificity = 90.6%), Medicaid payment for delivery (sensitivity = 82.4%, specificity = 85.6%), and breastfeeding initiation (sensitivity = 94.3%, specificity = 76.0%). The prevalence estimates were higher on PRAMS than the birth certificate for each of the indicators except Medicaid-paid delivery among non-Hispanic black women. Kappa values within most subgroups remained in the moderate range (0.40-0.80). Sensitivity and specificity values were lower for Hispanic women who responded to the PRAMS survey in Spanish and for breastfeeding initiation among women who delivered very low birthweight and very preterm infants. The validity and reliability of the PRAMS data for measures assessed were high. Our findings support the use of PRAMS data for epidemiological surveillance, research, and planning.
Comparison of Clinical, Maternal, and Self Pubertal Assessments: Implications for Health Studies
Goldberg, Mandy; Schechter, Sarah; Houghton, Lauren C.; White, Melissa L.; O’Toole, Karen; Chung, Wendy K.; Daly, Mary B.; Keegan, Theresa H.M.; Andrulis, Irene L.; Bradbury, Angela R.; Schwartz, Lisa; Knight, Julia A.; John, Esther M.; Buys, Saundra S.
2016-01-01
BACKGROUND: Most epidemiologic studies of puberty have only 1 source of pubertal development information (maternal, self or clinical). Interpretation of results across studies requires data on reliability and validity across sources. METHODS: The LEGACY Girls Study, a 5-site prospective study of girls aged 6 to 13 years (n = 1040) collected information on breast and pubic hair development from mothers (for all daughters) and daughters (if ≥10 years) according to Tanner stage (T1–5) drawings. At 2 LEGACY sites, girls (n = 282) were also examined in the clinic by trained professionals. We assessed agreement (κ) and validity (sensitivity and specificity) with the clinical assessment (gold standard) for both the mothers’ and daughters’ assessment in the subcohort of 282. In the entire cohort, we examined the agreement between mothers and daughters. RESULTS: Compared with clinical assessment, sensitivity of maternal assessment for breast development was 77.2 and specificity was 94.3. In girls aged ≥11 years, self-assessment had higher sensitivity and specificity than maternal report. Specificity for both mothers and self, but not sensitivity, was significantly lower for overweight girls. In the overall cohort, maternal and daughter agreement for breast development and pubic hair development (T2+ vs T1) were similar (0.66, [95% confidence interval 0.58–0.75] and 0.69 [95% confidence interval 0.61–0.77], respectively), but declined with age. Mothers were more likely to report a lower Tanner stage for both breast and pubic hair compared with self-assessments. CONCLUSIONS: These differences in validity should be considered in studies measuring pubertal changes longitudinally when they do not have access to clinical assessments. PMID:27279647
Ueda, Jun; Yoshimura, Hajime; Shimizu, Keiji; Hino, Megumu; Kohara, Nobuo
2017-07-01
Visual and semi-quantitative assessments of 123 I-FP-CIT single-photon emission computed tomography (SPECT) are useful for the diagnosis of dopaminergic neurodegenerative diseases (dNDD), including Parkinson's disease, dementia with Lewy bodies, progressive supranuclear palsy, multiple system atrophy, and corticobasal degeneration. However, the diagnostic value of combined visual and semi-quantitative assessment in dNDD remains unclear. Among 239 consecutive patients with a newly diagnosed possible parkinsonian syndrome who underwent 123 I-FP-CIT SPECT in our medical center, 114 patients with a disease duration less than 7 years were diagnosed as dNDD with the established criteria or as non-dNDD according to clinical judgment. We retrospectively examined their clinical characteristics and visual and semi-quantitative assessments of 123 I-FP-CIT SPECT. The striatal binding ratio (SBR) was used as a semi-quantitative measure of 123 I-FP-CIT SPECT. We calculated the sensitivity and specificity of visual assessment alone, semi-quantitative assessment alone, and combined visual and semi-quantitative assessment for the diagnosis of dNDD. SBR was correlated with visual assessment. Some dNDD patients with a normal visual assessment had an abnormal SBR, and vice versa. There was no statistically significant difference between sensitivity of the diagnosis with visual assessment alone and semi-quantitative assessment alone (91.2 vs. 86.8%, respectively, p = 0.29). Combined visual and semi-quantitative assessment demonstrated superior sensitivity (96.7%) to visual assessment (p = 0.03) or semi-quantitative assessment (p = 0.003) alone with equal specificity. Visual and semi-quantitative assessments of 123 I-FP-CIT SPECT are helpful for the diagnosis of dNDD, and combined visual and semi-quantitative assessment shows superior sensitivity with equal specificity.
Nadri, Johara; Sauvageot, Delphine; Njanpop-Lafourcade, Berthe-Marie; Baltazar, Cynthia S; Banla Kere, Abiba; Bwire, Godfrey; Coulibaly, Daouda; Kacou N'Douba, Adele; Kagirita, Atek; Keita, Sakoba; Koivogui, Lamine; Landoh, Dadja E; Langa, Jose P; Miwanda, Berthe N; Mutombo Ndongala, Guy; Mwakapeje, Elibariki R; Mwambeta, Jacob L; Mengel, Martin A; Gessner, Bradford D
2018-04-01
During 2014, Africa reported more than half of the global suspected cholera cases. Based on the data collected from seven countries in the African Cholera Surveillance Network (Africhol), we assessed the sensitivity, specificity, and positive and negative predictive values of clinical cholera case definitions, including that recommended by the World Health Organization (WHO) using culture confirmation as the gold standard. The study was designed to assess results in real-world field situations in settings with recent cholera outbreaks or endemicity. From June 2011 to July 2015, a total of 5,084 persons with suspected cholera were tested for Vibrio cholerae in seven different countries of which 35.7% had culture confirmation. For all countries combined, the WHO case definition had a sensitivity = 92.7%, specificity = 8.1%, positive predictive value = 36.1%, and negative predictive value = 66.6%. Adding dehydration, vomiting, or rice water stools to the case definition could increase the specificity without a substantial decrease in sensitivity. Future studies could further refine our findings primarily by using more sensitive methods for cholera confirmation.
Duran, Ibrahim; Schulze, Josefa; Martakis, KyriakoS; Stark, Christina; Schoenau, Eckhard
2018-03-07
To assess the diagnostic performance of body mass index (BMI) cut-off values according to recommendations of the World Health Organization (WHO), the World Obesity Federation (WOF), and the German Society for Adiposity (DAG) to identify excess body fat in children with cerebral palsy (CP). The present study was a monocentric retrospective analysis of prospectively collected data among children and adolescents with CP participating in a rehabilitation programme. Excess body fat was defined as a body fat percentage above the 85th centile assessed by dual-energy X-ray absorptiometry. In total, 329 children (181 males, 148 females) with CP were eligible for analysis. The mean age was 12 years 4 months (standard deviation 2y 9mo). The BMI cut-off values for 'overweight' according to the WHO, WOF, and DAG showed the following sensitivities and specificities for the prediction of excess body fat in our population: WHO: sensitivity 0.768 (95% confidence interval [CI] 0.636-0.870), specificity 0.894 (95% CI 0.851-0.928); WOF: sensitivity 0.696 (95% CI 0.559-0.812), specificity 0.934 (95% CI 0.898-0.960); DAG: sensitivity 0.411 (95% CI 0.281-0.550), specificity 0.993 (95% CI 0.974-0.999). Body mass index showed high specificity, but low sensitivity in children with CP. Thus, 'normal-weight obese' children with CP were overlooked, when assessing excess body fat only using BMI. Excess body fat in children with cerebral palsy (CP) is less common than previously reported. Body mass index (BMI) had high specificity but low sensitivity in detecting excess body fat in children with CP. BMI evaluation criteria of the German Society for Adiposity could be improved in children with CP. © 2018 Mac Keith Press.
Kogan, Dmitriy; Jain, Arad; Kimbro, Shawn; Gutierrez, Guillermo; Jain, Vivek
2016-08-01
Respiratory inductance plethysmography (RIP) is a tool used during a polysomnogram (PSG), which serves as a surrogate of respiratory effort and can help detect inspiratory air-flow limitation. We hypothesize that RIP can improve the sensitivity and specificity of scoring hypopneas when compared with both the recommended and acceptable criteria of the American Academy of Sleep Medicine. We retrospectively analyzed a cohort of 12 subjects who had no obstructive sleep apnea (OSA) or mild OSA on PSG when scored by the American Academy of Sleep Medicine acceptable criteria for hypopneas but had high clinical suspicion for a diagnosis of OSA. These subjects were rescored using the American Academy of Sleep Medicine recommended criteria as well as RIP. Hypopnea was scored when there was a 50% decrease in the amplitude of the RIP sum channel (which combined input from chest and abdominal belts). OSA was diagnosed if the subjects had >5 respiratory events/h of sleep. The subject's response to CPAP was assessed by using a short questionnaire called the post-PSG sleep assessment. which evaluated subjective sleep quality. A positive response was considered an improvement in the post-PSG sleep assessment score after CPAP use. When scored using the American Academy of Sleep Medicine acceptable criteria, 10 subjects had a negative study, and 2 subjects had mild OSA for a sensitivity of 11% and specificity of 50%. When scored using the recommended criteria, 10 subjects had OSA, and 2 were negative, for a sensitivity of 78% and specificity of 70%. By RIP scoring, all 12 subjects had >5 respiratory events/h for a sensitivity of 100% and specificity of 75%. This small retrospective pilot study showed improved sensitivity and specificity when scoring hypopneas by RIP sum channel. Copyright © 2016 by Daedalus Enterprises.
Sensitivity and specificity of the 3-item memory test in the assessment of post traumatic amnesia.
Andriessen, Teuntje M J C; de Jong, Ben; Jacobs, Bram; van der Werf, Sieberen P; Vos, Pieter E
2009-04-01
To investigate how the type of stimulus (pictures or words) and the method of reproduction (free recall or recognition after a short or a long delay) affect the sensitivity and specificity of a 3-item memory test in the assessment of post traumatic amnesia (PTA). Daily testing was performed in 64 consecutively admitted traumatic brain injured patients, 22 orthopedically injured patients and 26 healthy controls until criteria for resolution of PTA were reached. Subjects were randomly assigned to a test with visual or verbal stimuli. Short delay reproduction was tested after an interval of 3-5 minutes, long delay reproduction was tested after 24 hours. Sensitivity and specificity were calculated over the first 4 test days. The 3-word test showed higher sensitivity than the 3-picture test, while specificity of the two tests was equally high. Free recall was a more effortful task than recognition for both patients and controls. In patients, a longer delay between registration and recall resulted in a significant decrease in the number of items reproduced. Presence of PTA is best assessed with a memory test that incorporates the free recall of words after a long delay.
Brief assessment of food insecurity accurately identifies high-risk US adults.
Gundersen, Craig; Engelhard, Emily E; Crumbaugh, Amy S; Seligman, Hilary K
2017-06-01
To facilitate the introduction of food insecurity screening into clinical settings, we examined the test performance of two-item screening questions for food insecurity against the US Department of Agriculture's Core Food Security Module. We examined sensitivity, specificity and accuracy of various two-item combinations of questions assessing food insecurity in the general population and high-risk population subgroups. 2013 Current Population Survey December Supplement, a population-based US survey. All survey participants from the general population and high-risk subgroups. The test characteristics of multiple two-item combinations of questions assessing food insecurity had adequate sensitivity (>97 %) and specificity (>70 %) for widespread adoption as clinical screening measures. We recommend two specific items for clinical screening programmes based on their widespread current use and high sensitivity for detecting food insecurity. These items query how often the household 'worried whether food would run out before we got money to buy more' and how often 'the food that we bought just didn't last and we didn't have money to get more'. The recommended items have sensitivity across high-risk population subgroups of ≥97 % and a specificity of ≥74 % for food insecurity.
NASA Astrophysics Data System (ADS)
Tan, Juntao; Yang, Nuo; Hu, Zixi; Su, Jing; Zhong, Jianhong; Yang, Yang; Yu, Yating; Zhu, Jianmeng; Xue, Dabin; Huang, Yingying; Lai, Zongqiang; Huang, Yong; Lu, Xiaoling; Zhao, Yongxiang
2016-06-01
A simple, highly sensitive method to detect leukemia cells has been developed based on aptamer-modified fluorescent silica nanoparticles (FSNPs). In this strategy, the amine-labeled Sgc8 aptamer was conjugated to carboxyl-modified FSNPs via amide coupling between amino and carboxyl groups. Sensitivity and specificity of Sgc8-FSNPs were assessed using flow cytometry and fluorescence microscopy. These results showed that Sgc8-FSNPs detected leukemia cells with high sensitivity and specificity. Aptamer-modified FSNPs hold promise for sensitive and specific detection of leukemia cells. Changing the aptamer may allow the FSNPs to detect other types of cancer cells.
Fisher, Jolene H; Al-Hejaili, Faris; Kandel, Sonja; Hirji, Alim; Shapera, Shane; Mura, Marco
2017-04-01
The heterogeneous progression of idiopathic pulmonary fibrosis (IPF) makes prognostication difficult and contributes to high mortality on the waitlist for lung transplantation (LTx). Multi-dimensional scores (Composite Physiologic index [CPI], [Gender-Age-Physiology [GAP]; RIsk Stratification scorE [RISE]) demonstrated enhanced predictive power towards outcome in IPF. The lung allocation score (LAS) is a multi-dimensional tool commonly used to stratify patients assessed for LTx. We sought to investigate whether IPF-specific multi-dimensional scores predict mortality in patients with IPF assessed for LTx. The study included 302 patients with IPF who underwent a LTx assessment (2003-2014). Multi-dimensional scores were calculated. The primary outcome was 12-month mortality after assessment. LTx was considered as competing event in all analyses. At the end of the observation period, there were 134 transplants, 63 deaths, and 105 patients were alive without LTx. Multi-dimensional scores predicted mortality with accuracy similar to LAS, and superior to that of individual variables: area under the curve (AUC) for LAS was 0.78 (sensitivity 71%, specificity 86%); CPI 0.75 (sensitivity 67%, specificity 82%); GAP 0.67 (sensitivity 59%, specificity 74%); RISE 0.78 (sensitivity 71%, specificity 84%). A separate analysis conducted only in patients actively listed for LTx (n = 247; 50 deaths) yielded similar results. In patients with IPF assessed for LTx as well as in those actually listed, multi-dimensional scores predict mortality better than individual variables, and with accuracy similar to the LAS. If validated, multi-dimensional scores may serve as inexpensive tools to guide decisions on the timing of referral and listing for LTx. Copyright © 2017 Elsevier Ltd. All rights reserved.
Weissberger, Gali H; Strong, Jessica V; Stefanidis, Kayla B; Summers, Mathew J; Bondi, Mark W; Stricker, Nikki H
2017-12-01
With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer's dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer's disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers.
Hanisch, Karen; Küster, Eberhard; Altenburger, Rolf; Gündel, Ulrike
2010-01-01
Studies using embryos of the zebrafish Danio rerio (DarT) instead of adult fish for characterising the (eco-) toxic potential of chemicals have been proposed as animal replacing methods. Effect analysis at the molecular level might enhance sensitivity, specificity, and predictive value of the embryonal studies. The present paper aimed to test the potential of toxicoproteomics with zebrafish eleutheroembryos for sensitive and specific toxicity assessment. 2-DE-based toxicoproteomics was performed applying low-dose (EC(10)) exposure for 48 h with three-model substances Rotenone, 4,6-dinitro-o-cresol (DNOC) and Diclofenac. By multivariate "pattern-only" PCA and univariate statistical analyses, alterations in the embryonal proteome were detectable in nonetheless visibly intact organisms and treatment with the three substances was distinguishable at the molecular level. Toxicoproteomics enabled the enhancement of sensitivity and specificity of the embryonal toxicity assay and bear the potency to identify protein markers serving as general stress markers and early diagnosis of toxic stress.
Hanisch, Karen; Küster, Eberhard; Altenburger, Rolf; Gündel, Ulrike
2010-01-01
Studies using embryos of the zebrafish Danio rerio (DarT) instead of adult fish for characterising the (eco-) toxic potential of chemicals have been proposed as animal replacing methods. Effect analysis at the molecular level might enhance sensitivity, specificity, and predictive value of the embryonal studies. The present paper aimed to test the potential of toxicoproteomics with zebrafish eleutheroembryos for sensitive and specific toxicity assessment. 2-DE-based toxicoproteomics was performed applying low-dose (EC10) exposure for 48 h with three-model substances Rotenone, 4,6-dinitro-o-cresol (DNOC) and Diclofenac. By multivariate “pattern-only” PCA and univariate statistical analyses, alterations in the embryonal proteome were detectable in nonetheless visibly intact organisms and treatment with the three substances was distinguishable at the molecular level. Toxicoproteomics enabled the enhancement of sensitivity and specificity of the embryonal toxicity assay and bear the potency to identify protein markers serving as general stress markers and early diagnosis of toxic stress. PMID:22084678
Gili, Pablo; Flores-Rodríguez, Patricia; Yangüela, Julio; Orduña-Azcona, Javier; Martín-Ríos, María Dolores
2013-03-01
Evaluation of the efficacy of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen (ONHD) and optic disc oedema (ODE). Sixty-six patients with ONHD, 31 patients with ODE and 70 healthy subjects were studied. Colour and monochromatic fundus photography with different filters (green, red and autofluorescence) were performed. The results were analysed blindly by two observers. The sensitivity, specificity and interobserver agreement (k) of each test were assessed. Colour photography offers 65.5 % sensitivity and 100 % specificity for the diagnosis of ONHD. Monochromatic photography improves sensitivity and specificity and provides similar results: green filter (71.20 % sensitivity, 96.70 % specificity), red filter (80.30 % sensitivity, 96.80 % specificity), and autofluorescence technique (87.8 % sensitivity, 100 % specificity). The interobserver agreement was good with all techniques used: autofluorescence (k = 0.957), green filter (k = 0.897), red filter (k = 0.818) and colour (k = 0.809). Monochromatic fundus photography permits ONHD and ODE to be differentiated, with good sensitivity and very high specificity. The best results were obtained with autofluorescence and red filter study.
Zielinski, Ingar Marie; Steenbergen, Bert; Schmidt, Anna; Klingels, Katrijn; Simon Martinez, Cristina; de Water, Pascal; Hoare, Brian
2018-03-23
To introduce the Windmill-task, a new objective assessment tool to quantify the presence of mirror movements (MMs) in children with unilateral cerebral palsy (UCP), which are typically assessed with the observation-based Woods and Teuber scale (W&T). Prospective, observational, cohort pilot study. Children's hospital. Prospective cohort of children (N=23) with UCP (age range, 6-15y, mean age, 10.5±2.7y). Not applicable. The concurrent validity of the Windmill-task is assessed, and the sensitivity and specificity for MM detection are compared between both assessments. To assess the concurrent validity, Windmill-task data are compared with W&T data using Spearman rank correlations (ρ) for 2 conditions: affected hand moving vs less affected hand moving. Sensitivity and specificity are compared by measuring the mean percentage of children being assessed inconsistently across both assessments. Outcomes of both assessments correlated significantly (affected hand moving: ρ=.520; P=.005; less affected hand moving: ρ=.488; P=.009). However, many children displayed MMs on the Windmill-task, but not on the W&T (sensitivity: affected hand moving: 27.5%; less affected hand moving: 40.6%). Only 2 children displayed MMs on the W&T, but not on the Windmill-task (specificity: affected hand moving: 2.9%; less affected hand moving: 1.4%). The Windmill-task seems to be a valid tool to assess MMs in children with UCP and has an additional advantage of sensitivity to detect MMs. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Hwang, Harry S; Orloff, Lisa A
2011-03-01
This study was performed to assess the diagnostic accuracy of surgeon-performed preoperative neck ultrasound (US) in the detection of both central and lateral cervical lymph node metastases from thyroid cancer. Prospective cohort study. Data for all patients with thyroid cancers and follicular thyroid lesions who were evaluated by means of preoperative neck US were reviewed. The cervical lymph nodes were assessed for suspicion of metastasis based on US characteristics. The diagnostic accuracy of US was determined according to whether histologically confirmed cancer was present in surgical cervical lymph node specimens. The sensitivity and specificity of US in predicting papillary thyroid carcinoma (PTC) metastasis in the central neck were 30.0% and 86.8%, respectively. The sensitivity and specificity of US in predicting metastasis in the lateral neck were 93.8% and 80.0%, respectively. A subset of patients underwent US followed by revision neck dissection for PTC, and the sensitivity and specificity of US in predicting metastasis in the lateral neck were 100% and 100%, respectively. Preoperative neck US is a valuable tool in assessing patients with thyroid cancers. The highly sensitive and specific nature of US in predicting cervical lymph node metastasis in the lateral neck, especially in the setting of recurrent disease, can provide reliable information to assist in surgical management. Although US for central compartment lymphadenopathy in the presence of the thyroid gland is less sensitive and specific than US for the lateral neck, it still provides useful information that can be obtained at the same time the primary thyroid pathology is assessed. Copyright © 2010 The American Laryngological, Rhinological, and Otological Society, Inc.
Chatzopoulos, Georgios S; Tsalikis, Lazaros; Konstantinidis, Antonios; Kotsakis, Georgios A
2016-10-01
The assessment of periodontitis and treatment needs is primarily based on clinical and radiographic examinations. Albeit effective in predicting treatment needs, these examinations are costly, time-consuming, and impractical for assessing population-level needs. The purpose of the present study is to evaluate a two-domain self-report questionnaire for rapid periodontitis screening. Six hundred white adult individuals, dentate or partially dentate and seeking dental therapy at a university clinic, underwent oral examination utilizing the full-mouth Community Periodontal Index of Treatment Needs (CPITN). To assess predictive value of self-reported periodontal measures (SRPMs) for periodontitis screening, four questions were formulated. Two questions aimed to assess "dentist-diagnosed periodontal disease" and two inquired about "self-assessed periodontitis." Multiple logistic regression models were used to construct receiver-operating characteristic curves, and predictor selection was performed via a forward stepwise selection process. Five hundred thirty-five volunteers with a mean age of 50.1 years elected to respond to SRPMs via telephone interview. After oral examination, 17.8% of participants were assessed as having CPITN = 4, representing compromised periodontal status. Sensitivity and specificity for correctly classifying compromised periodontal status ranged from 5.3% to 72.6%, and 87.8% to 99.5% for individual SRPMs. Sensitivity and specificity were increased when combining a measure of self-assessed periodontal disease and a measure of dentist-diagnosed disease as predictors. Addition of age and sex maximized sensitivity/specificity at 82.1%/82.2%. Diabetic status, smoking, and body mass index did not enhance the prediction. A two-domain self-report measure combining two self-report items with age and sex has good sensitivity and specificity for periodontitis screening in a white, university-based population. The proposed self-report measure can be valuable for periodontitis screening in resource-limited settings where gold standard clinical examination may not be pragmatic. Further validation studies are required to assess whether findings from this study are context-specific.
DOT National Transportation Integrated Search
1983-01-01
A variety of measurements are sensitive to alcoholism; some may be applicable to screening programs, but more precise knowledge of sensitivity and specificity would help to select a minimal test battery. This study assessed the sensitivity of some te...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klech, H.; Kohn, H.; Kummer, F.
1982-12-01
The value of different factors are examined to assess activity in 60 patients with biopsy-proven sarcoidosis. In patients with active sarcoidosis (n . 35), /sup 67/Ga scans proved to be the most sensitive method (94 percent sensitivity), followed by serum angiotensin I converting enzyme (S-ACE) levels, chest x-ray films, and lymphocyte assays. In patients with peripheral pulmonary lesions, chest x-ray films failed in 32 percent of cases to document activity (68 percent sensitivity) whereas /sup 67/Ga scans and S-ACE levels remained to give reliable results. Despite poor specificity, negative /sup 67/Ga scans together with normal ACE levels have a highmore » predictive value for exclusion of active sarcoidosis. In patients with peripheral pulmonary lesions, chest roentgenography is of doubtful value for staging lung involvement and assessment of activity including monitoring and control of therapy.« less
Nishi, Fernanda Ayache; de Oliveira Motta Maia, Flávia; de Souza Santos, Itamar; de Almeida Lopes Monteiro da Cruz, Dina
2017-06-01
Triage is the first assessment and sorting process used to prioritize patients arriving in the emergency department (ED). As a triage tool, the Manchester Triage System (MTS) must have a high sensitivity to minimize the occurrence of under-triage, but must not compromise specificity to avoid the occurrence of overtriage. Sensitivity and specificity of the MTS can be calculated using the frequency of appropriately assigned clinical priority levels for patients presenting to the ED. However, although there are well established criteria for the prioritization of patients with suspected acute coronary syndrome (ACS), several studies have reported difficulties when evaluating patients with this condition. The objective of this review was to synthesize the best available evidence on assessing the sensitivity and specificity of the MTS for screening high-level priority adult patients presenting to the ED with ACS. The current review considered studies that evaluated the use of the MTS in the risk classification of adult patients in the ED. In this review, studies that investigated the priority level, as established by the MTS to screen patients under suspicion of ACS or the sensitivity and specificity of the MTS, for screening patients before the medical diagnosis of ACS were included. This review included both experimental and epidemiological study designs. The results were presented in a narrative synthesis. Six studies were appraised by the independent reviewers. All appraised studies enrolled a consecutive or random sample of patients and presented an overall moderate methodological quality, and all of them were included in this review. A total of 54,176 participants were included in the six studies. All studies were retrospective. Studies included in this review varied in content and data reporting. Only two studies reported sensitivity and specificity values or all the necessary data to calculate sensitivity and specificity. The remaining four studies presented either a sensitivity analysis or the number of true positives and false negatives. However, these four studies were conducted considering only data from patients diagnosed with ACS. Sensitivity values were relatively uniform among the studies: 0.70-0.80. A specificity of 0.59 was reported in the study including only patients with non-traumatic chest pain. On the other hand, in the study that included patients with any complaint, the specificity of MTS to screen patients with ACS was 0.97. The current review demonstrates that the MTS has a moderate sensitivity to evaluate patients with ACS. This may compromise time to treatment in the ED, an important variable in the prognosis of ACS. Atypical presentation of ACS, or high specificity, may also explain the moderate sensitivity demonstrated in this review. However, because of minimal data, it is not possible to confirm this hypothesis. It is difficult to determine the acceptable level of sensitivity or specificity to ensure that a certain triage system is safe.
The role of disgust in patients with hypochondriasis.
Weck, Florian; Esch, Sebastian; Rohrmann, Sonja
2014-01-01
Theoretically, disgust sensitivity and disgust proneness could play an important role in hypochondriasis, since disgust is a defensive emotion widely believed to protect the organism from illness. However, empirical evidence to support this hypothesis has so far been based only on nonclinical samples, so that the importance and specificity of disgust for hypochondriasis remains unclear. In the current study, 36 patients with hypochondriasis, 27 with an anxiety disorder, and 29 healthy controls completed several measures which included the assessment of disgust sensitivity (Scale for the Assessment of Disgust Sensitivity) and disgust proneness (Questionnaire for the Assessment of Disgust Proneness). We found that patients with hypochondriasis and those with an anxiety disorder had higher scores than those of the healthy controls for several measures of disgust proneness. Moreover, measures of hypochondriacal characteristics were associated with those of disgust proneness and disgust sensitivity. However, no differences were found between patients with hypochondriasis and those with anxiety disorders, with respect to disgust proneness and disgust sensitivity. Therefore, it can be assumed that disgust proneness and disgust sensitivity seem to be less specific than previously suggested for the development and maintenance of hypochondriasis.
Uysal-Cantürk, P; Hanağası, H A; Bilgiç, B; Gürvit, H; Emre, M
2018-01-01
Cognitive impairment is one of the most disabling non-motor symptoms of Parkinson's disease. Mild cognitive impairment constitutes a major risk for the development of Parkinson's disease dementia in the course of the disease. A Movement Disorder Society Task Force proposed diagnostic criteria for mild cognitive impairment in Parkinson's disease (PD-MCI), comprising two operational levels: Level I and Level II. The objective of our study was to test the accuracy of Level I versus Level II diagnostic criteria. Eighty-six consecutive patients with Parkinson's disease were screened and 68 patients without dementia or depression were included in the study. We used the Montreal Cognitive Assessment, Mini-Mental State Examination and Addenbrooke's Cognitive Evaluation-R screening tools for Level I and an extensive neuropsychological battery for Level II assessment. We first diagnosed PD-MCI on the basis of Level II assessment and then calculated sensitivity, specificity and area under the receiver-operator characteristics curve, comparing the performance of the three screening batteries. None of the three screening batteries proposed for Level I assessment provided satisfactory combined sensitivity and specificity for detecting PD-MCI, and their performance was similar. Using the Level II criteria, 29 patients (43%) were diagnosed as having PD-MCI. Lowest cut-off levels that provided at least 80% sensitivity were 24 for the Montreal Cognitive Assessment, 29 for the Mini-Mental State Examination and 87 for the Addenbrooke's Cognitive Evaluation-R. However, specificity levels were below 80% at these cut-off levels. We conclude that Level I assessment alone using screening batteries is not sufficiently sensitive/specific to detect PD-MCI. © 2017 EAN.
Xu, Chang Fen; Tan, Eugene S J; Feng, Liang; Santhanakrishnan, Rajalakshmi; Chan, Michelle M Y; Nyunt, Shwe Zin; Ng, Tze Pin; Ling, Lieng Hsi; Richards, A Mark; Lam, Carolyn S P; Lim, Toon Wei
2015-08-01
Electrocardiographic (ECG) criteria for left ventricular hypertrophy (LVH), such as the Cornell and Sokolow-Lyon voltage criteria were derived from Western populations. However, their utility and accuracy for diagnosing echocardiographic LVH in Asian populations is unclear. The objective of this study was to assess the accuracy of ECG criteria for LVH in Asians and to determine if alternative gender-specific ECG cut-offs may improve its diagnostic accuracy. ECG and echocardiographic assessments were performed on 668 community-dwelling Asian adults (50.9% women; 57 ± 10 years) in Singapore. The accuracy of ECG voltage criteria was compared to echocardiographic LVH criteria based on the American Society of Echocardiography guidelines, and Asian ethnicity and gender-specific partition values. Echocardiographic LVH was present in 93 (13.6%) adults. Cornell criteria had low sensitivity (5.5%) and high specificity (98.9%) for diagnosing LVH. Modified gender specific cut-offs (18 mm in women, 22 mm in men) improved sensitivity (8.8% to 17.5%, 0% to 14.7%, respectively) whilst preserving specificity (98.2% to 94.2%, 100% to 95.8%). Similarly, Sokolow-Lyon criteria had poor sensitivity (7.7%) and high specificity (96.1%) for diagnosing LVH. Lowering the cut-off value from 35 mm to 31 mm improved the sensitivity in women from 3.5% to 14% while preserving specificity at 94.2%. A cut-off of 36 mm was optimal in men (sensitivity of 14.7%, specificity of 95.5%). Current ECG criteria for LVH derived in Western cohorts have limited sensitivity in Asian populations. Our data suggests that ethnicity- and gender-specific ECG criteria may be needed.
A PRELIMINARY assessment of BCG vacination in India.
1955-01-01
A NEW ASSESSMENT ACTIVITY IN RELATION TO THE WHO/UNICEF BCG VACCINATION PROGRAMME IS DESCRIBED IN THIS REPORT: according to a detailed plan special field teams collect data on tuberculin sensitivity to determine how efficiently children are being selected for vaccination and to appraise the allergy produced by the mass vaccinations. Results of nine months' work in India have important implications for the practical BCG work.Testing of unvaccinated groups of schoolchildren shows that the pattern of tuberculin sensitivity differs in different parts of India. Specific tuberculin sensitivity is found in all areas, as evidenced by strong reactions to the 5 TU test. Many children had a low-grade non-specific sensitivity, evidenced by small reactions to 5 TU and large reactions to 100 TU. This non-specific tuberculin sensitivity was less frequent at high altitudes, and most common in low-lying humid areas: in all areas it was more prevalent than specific sensitivity.In some areas non-specific tuberculin sensitivity is so strong that it cannot be effectively distinguished from specific sensitivity: consequently, many children not infected with tuberculosis are undoubtedly being excluded from vaccination.Sample retesting of children vaccinated in the mass campaign revealed variable levels of allergy, in many instances much lower than had been expected. These results cannot be explained by a native incapacity of the Indian children to develop strong allergy-nor presumably by the vaccine used. Impairment of the vaccine by exposure to light could be no more than a contributory factor. The marked variability of the campaign results suggests that some factor connected with the handling or application of the vaccine (or possibly of the tuberculin) is involved.
Resch, Jacob E; Brown, Cathleen N; Schmidt, Julianne; Macciocchi, Stephen N; Blueitt, Damond; Cullum, C Munro; Ferrara, Michael S
2016-01-01
A battery of clinical measures of neurocognition, balance and symptoms has been recommended for the management of sport concussion (SC) but is based on variable evidence. To examine the sensitivity and specificity of a battery of tests to assess SC in college athletes. Cross-sectional. Research laboratory. Division 1 athletes diagnosed with a SC (n=40) who were 20.2±1.60 years of age and 180.5±11.12 cm tall and healthy athletes (n=40) who were 19.0±0.93 years of age and 179.1±11.39 cm tall were enrolled. Participants were administered Immediate Postconcussion Assessment and Cognitive Test (ImPACT), the Sensory Organization Test (SOT) and the Revised Head Injury Scale (HIS-r) prior to and up to 24 h following injury between the 2004 and 2014 sport seasons. Sensitivity and specificity were calculated using predictive discriminant analyses (PDA) and clinical interpretation guidelines. Outcome measures included baseline and postinjury ImPACT, SOT and HIS-r composite scores. Using PDA, each clinical measure's sensitivity ranged from 55.0% to 77.5% and specificity ranged from 52.5% to 100%. The test battery possessed a sensitivity and specificity of 80.0% and 100%, respectively. Using clinical interpretation guidelines, sensitivity ranged from 55% to 97.5% individually, and 100% when combined. Our results support a multidimensional approach to assess SC in college athletes which correctly identified 80-100% of concussed participants as injured. When each test was evaluated separately, up to 47.5% of our sample was misclassified. Caution is warranted when using singular measures to manage SC.
Resch, Jacob E; Brown, Cathleen N; Schmidt, Julianne; Macciocchi, Stephen N; Blueitt, Damond; Cullum, C Munro; Ferrara, Michael S
2016-01-01
Context A battery of clinical measures of neurocognition, balance and symptoms has been recommended for the management of sport concussion (SC) but is based on variable evidence. Objective To examine the sensitivity and specificity of a battery of tests to assess SC in college athletes. Design Cross-sectional. Setting Research laboratory. Patients or other participants Division 1 athletes diagnosed with a SC (n=40) who were 20.2±1.60 years of age and 180.5±11.12 cm tall and healthy athletes (n=40) who were 19.0±0.93 years of age and 179.1±11.39 cm tall were enrolled. Intervention(s) Participants were administered Immediate Postconcussion Assessment and Cognitive Test (ImPACT), the Sensory Organization Test (SOT) and the Revised Head Injury Scale (HIS-r) prior to and up to 24 h following injury between the 2004 and 2014 sport seasons. Sensitivity and specificity were calculated using predictive discriminant analyses (PDA) and clinical interpretation guidelines. Main outcome measures Outcome measures included baseline and postinjury ImPACT, SOT and HIS-r composite scores. Results Using PDA, each clinical measure's sensitivity ranged from 55.0% to 77.5% and specificity ranged from 52.5% to 100%. The test battery possessed a sensitivity and specificity of 80.0% and 100%, respectively. Using clinical interpretation guidelines, sensitivity ranged from 55% to 97.5% individually, and 100% when combined. Conclusions Our results support a multidimensional approach to assess SC in college athletes which correctly identified 80–100% of concussed participants as injured. When each test was evaluated separately, up to 47.5% of our sample was misclassified. Caution is warranted when using singular measures to manage SC. PMID:27900145
Population and High-Risk Group Screening for Glaucoma: The Los Angeles Latino Eye Study
Francis, Brian A.; Vigen, Cheryl; Lai, Mei-Ying; Winarko, Jonathan; Nguyen, Betsy; Azen, Stanley
2011-01-01
Purpose. To evaluate the ability of various screening tests, both individually and in combination, to detect glaucoma in the general Latino population and high-risk subgroups. Methods. The Los Angeles Latino Eye Study is a population-based study of eye disease in Latinos 40 years of age and older. Participants (n = 6082) underwent Humphrey visual field testing (HVF), frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP) and central corneal thickness (CCT), and independent assessment of optic nerve vertical cup disc (C/D) ratio. Screening parameters were evaluated for three definitions of glaucoma based on optic disc, visual field, and a combination of both. Analyses were also conducted for high-risk subgroups (family history of glaucoma, diabetes mellitus, and age ≥65 years). Sensitivity, specificity, and receiver operating characteristic curves were calculated for those continuous parameters independently associated with glaucoma. Classification and regression tree (CART) analysis was used to develop a multivariate algorithm for glaucoma screening. Results. Preset cutoffs for screening parameters yielded a generally poor balance of sensitivity and specificity (sensitivity/specificity for IOP ≥21 mm Hg and C/D ≥0.8 was 0.24/0.97 and 0.60/0.98, respectively). Assessment of high-risk subgroups did not improve the sensitivity/specificity of individual screening parameters. A CART analysis using multiple screening parameters—C/D, HVF, and IOP—substantially improved the balance of sensitivity and specificity (sensitivity/specificity 0.92/0.92). Conclusions. No single screening parameter is useful for glaucoma screening. However, a combination of vertical C/D ratio, HVF, and IOP provides the best balance of sensitivity/specificity and is likely to provide the highest yield in glaucoma screening programs. PMID:21245400
Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.
Smith, R F; Mather, H M; Ellard, G A
1998-02-01
The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.
Zandrino, Franco; La Paglia, Ernesto; Musante, Francesco
2010-01-01
To assess the diagnostic accuracy of magnetic resonance imaging in local staging of endometrial carcinoma, and to review the results and pitfalls described in the literature. Thirty women with a histological diagnosis of endometrial carcinoma underwent magnetic resonance imaging. Unenhanced T2-weighted and dynamic contrast-enhanced Ti-weighted sequences were obtained. Hysterectomy and salpingo-oophorectomy was performed in all patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for the detection of deep myometrial and cervical infiltration. For deep myometrial infiltration T2-weighted sequences reached a sensitivity of 85%, specificity of 76%, PPV of 73%, NVP of 87%, and accuracy of 80%, while contrast-enhanced scans reached a sensitivity of 90%, specificity of 80%, PPV of 82%, NPV of 89%, and accuracy of 85%. For cervical infiltration T2-weighted sequences reached a sensitivity of 75%, specificity of 88%, PPV of 50%, NPV of 96%, and accuracy of 87%, while contrast-enhanced scans reached a sensitivity of 100%, specificity of 94%, PPV of 75%, NPV of 100%, and accuracy of 95%. Unenhanced and dynamic gadolinium-enhanced magnetic resonance allows accurate assessment of myometrial and cervical infiltration. Information provided by magnetic resonance imaging can define prognosis and management.
Darwin, Zoe; McGowan, Linda; Edozien, Leroy C
2016-02-01
Antenatal mental health assessment is increasingly common in high-income countries. Despite lacking evidence on validation or acceptability, the Whooley questions (modified PHQ-2) and Arroll 'help' question are used in the UK at booking (the first formal antenatal appointment) to identify possible cases of depression. This study investigated validation of the questions and women's views on assessment. Women (n = 191) booking at an inner-city hospital completed the Whooley and Arroll questions as part of their routine clinical care then completed a research questionnaire containing the Edinburgh postnatal depression scale (EPDS). A purposive subsample (n = 22) were subsequently interviewed. The Whooley questions 'missed' half the possible cases identified using the EPDS (EPDS threshold ≥ 10: sensitivity 45.7 %, specificity 92.1 %; ≥ 13: sensitivity 47.8 %, specificity 86.1 %), worsening to nine in ten when adopting the Arroll item (EPDS ≥ 10: sensitivity 9.1 %, specificity 98.2 %; ≥ 13: sensitivity 9.5 %, specificity 97.1 %). Women's accounts indicated that under-disclosure relates to the context of assessment and perceived relevance of depression to maternity services. Depression symptoms are under-identified in current local practice. While validated tools are needed that can be readily applied in routine maternity care, psychometric properties will be influenced by the context of disclosure when implemented in practice.
Real, Ruben G. L.; Kotchoubey, Boris; Kübler, Andrea
2014-01-01
This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT) as a method for the extraction and assessment of event-related brain potentials (ERP) in data from a single subject. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings. PMID:25309308
Real, Ruben G L; Kotchoubey, Boris; Kübler, Andrea
2014-01-01
This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT) as a method for the extraction and assessment of event-related brain potentials (ERP) in data from a single subject. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings.
Danilova, Ludmila; Anagnostou, Valsamo; Caushi, Justina X; Sidhom, John-William; Guo, Haidan; Chan, Hok Yee; Suri, Prerna; Tam, Ada J; Zhang, Jiajia; El Asmar, Margueritta; Marrone, Kristen A; Naidoo, Jarushka; Brahmer, Julie R; Forde, Patrick M; Baras, Alexander S; Cope, Leslie; Velculescu, Victor E; Pardoll, Drew; Housseau, Franck; Smith, Kellie N
2018-06-12
Mutation-associated neoantigens (MANAs) are a target of antitumor T-cell immunity. Sensitive, simple, and standardized assays are needed to assess the repertoire of functional MANA-specific T cells in oncology. Assays analyzing in vitro cytokine production such as ELISpot and intracellular cytokine staining (ICS) have been useful but have limited sensitivity in assessing tumor-specific T-cell responses and do not analyze antigen-specific T-cell repertoires. The FEST (Functional Expansion of Specific T cells) assay described herein integrates TCR sequencing of short-term, peptide-stimulated cultures with a bioinformatic platform to identify antigen-specific clonotypic amplifications. This assay can be adapted for all types of antigens, including mutation associated neoantigens (MANAs) via tumor exome-guided prediction of MANAs. Following in vitro identification by the MANAFEST assay, the MANA-specific CDR3 sequence can be used as a molecular barcode to detect and monitor the dynamics of these clonotypes in blood, tumor, and normal tissue of patients receiving immunotherapy. MANAFEST is compatible with high-throughput routine clinical and lab practices. Copyright ©2018, American Association for Cancer Research.
Sensitivity assessment of freshwater macroinvertebrates to pesticides using biological traits.
Ippolito, A; Todeschini, R; Vighi, M
2012-03-01
Assessing the sensitivity of different species to chemicals is one of the key points in predicting the effects of toxic compounds in the environment. Trait-based predicting methods have proved to be extremely efficient for assessing the sensitivity of macroinvertebrates toward compounds with non specific toxicity (narcotics). Nevertheless, predicting the sensitivity of organisms toward compounds with specific toxicity is much more complex, since it depends on the mode of action of the chemical. The aim of this work was to predict the sensitivity of several freshwater macroinvertebrates toward three classes of plant protection products: organophosphates, carbamates and pyrethroids. Two databases were built: one with sensitivity data (retrieved, evaluated and selected from the U.S. Environmental Protection Agency ECOTOX database) and the other with biological traits. Aside from the "traditional" traits usually considered in ecological analysis (i.e. body size, respiration technique, feeding habits, etc.), multivariate analysis was used to relate the sensitivity of organisms to some other characteristics which may be involved in the process of intoxication. Results confirmed that, besides traditional biological traits, related to uptake capability (e.g. body size and body shape) some traits more related to particular metabolic characteristics or patterns have a good predictive capacity on the sensitivity to these kinds of toxic substances. For example, behavioral complexity, assumed as an indicator of nervous system complexity, proved to be an important predictor of sensitivity towards these compounds. These results confirm the need for more complex traits to predict effects of highly specific substances. One key point for achieving a complete mechanistic understanding of the process is the choice of traits, whose role in the discrimination of sensitivity should be clearly interpretable, and not only statistically significant.
Woo, Sungmin; Suh, Chong Hyun; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup
2017-11-01
The purpose of this article is to systematically review and perform a meta-analysis of the diagnostic performance of CT for diagnosis of fat-poor angiomyolipoma (AML) in patients with renal masses. MEDLINE and EMBASE were systematically searched up to February 2, 2017. We included diagnostic accuracy studies that used CT for diagnosis of fat-poor AML in patients with renal masses, using pathologic examination as the reference standard. Two independent reviewers assessed the methodologic quality using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity of included studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Sensitivity analyses using several clinically relevant covariates were performed to explore heterogeneity. Fifteen studies (2258 patients) were included. Pooled sensitivity and specificity were 0.67 (95% CI, 0.48-0.81) and 0.97 (95% CI, 0.89-0.99), respectively. Substantial and considerable heterogeneity was present with regard to sensitivity and specificity (I 2 = 91.21% and 78.53%, respectively). At sensitivity analyses, the specificity estimates were comparable and consistently high across all subgroups (0.93-1.00), but sensitivity estimates showed significant variation (0.14-0.82). Studies using pixel distribution analysis (n = 3) showed substantially lower sensitivity estimates (0.14; 95% CI, 0.04-0.40) compared with the remaining 12 studies (0.81; 95% CI, 0.76-0.85). CT shows moderate sensitivity and excellent specificity for diagnosis of fat-poor AML in patients with renal masses. When methods other than pixel distribution analysis are used, better sensitivity can be achieved.
Dunham, Kathryn J.; Shadi, Sarah; Sofko, Channing A.; Denney, Robert L.; Calloway, Jordan
2014-01-01
The aim of the current study was to compare two embedded measures of effort for the repeatable battery for the assessment of neuropsychological status (RBANS). Sensitivity and specificity of the Effort Index (EI) and Effort Scale (ES) were compared in a sample of individuals with genuine memory impairment (MI) and individuals coached to simulate MI. Overall, the EI yielded a sensitivity of 0.89 and specificity of 0.41, while the ES yielded a sensitivity of 0.88 and specificity of 0.81. When those in the MI group were separated by level of impairment, the EI was more specific when RBANS Total Scores were in the average or mildly impaired range, and the ES had greater specificity when RBANS Total Scores were in the severely impaired range. These results suggest that the embedded measure should be selected based on the level of impairment on the RBANS. PMID:25236719
Ibrahim, Omer Mohammed Ali; Bilal, Naser Eldin; Osman, Omran Fadl; Magzoub, Magzoub Abbas
2017-01-01
The heterogeneous expression of methicillin resistance in Staphylococcus aureus (MRSA) affects the efficiency of tests available to detect it. The objective of this study was to assess four phenotypic tests used to detect MRSA. This is an analytical comparative study conducted among sudanese patients during period from May 2012 to July 2014, Staphylococcus aureus strains were isolated and identified by conventional methods, and then confirmed by PCR detection of coagulase gene. PCR detection of mecA gene was used as a gold standard to assess oxacillin resistance screen agar base (ORSAB), oxacillin disc, cefoxitin disc (at different temperatures and incubation periods) and MRSA-latex agglutination test. S.aureus ATCC 25923 was used as control. Sensitivity and specificity were calculated. MRSA- latex agglutination was the most accurate test; it showed 100% of both sensitivity and specificity, followed by cefoxitin disc with sensitivity of 98.48% and specificity of 100%. However, both of oxacillin disc and oxacillin resistance screen agar base showed less accurate results, and were affected by incubation periods. Oxacillin disc after 24 h incubation both at 30°C and 35°C showed sensitivity and specificity values of 87.88% and 96.23%, respectively. However, after 48h incubation the test at 30°C showed sensitivity and specificity values of 89.39%, and 94.34%, respectively. At 35°C (48h) it showed values of 89.39%, 92.45% respectively. Specificity of ORSAB was more than oxacillin disc at 35°C after 24h incubation 98.11% and 96.23%, respectively. MRSA- latex agglutination and cefoxitin disc diffusion tests are recommended for routine detection of MRSA.
An in vitro human skin test for assessing sensitization potential.
Ahmed, S S; Wang, X N; Fielding, M; Kerry, A; Dickinson, I; Munuswamy, R; Kimber, I; Dickinson, A M
2016-05-01
Sensitization to chemicals resulting in an allergy is an important health issue. The current gold-standard method for identification and characterization of skin-sensitizing chemicals was the mouse local lymph node assay (LLNA). However, for a number of reasons there has been an increasing imperative to develop alternative approaches to hazard identification that do not require the use of animals. Here we describe a human in-vitro skin explant test for identification of sensitization hazards and the assessment of relative skin sensitizing potency. This method measures histological damage in human skin as a readout of the immune response induced by the test material. Using this approach we have measured responses to 44 chemicals including skin sensitizers, pre/pro-haptens, respiratory sensitizers, non-sensitizing chemicals (including skin-irritants) and previously misclassified compounds. Based on comparisons with the LLNA, the skin explant test gave 95% specificity, 95% sensitivity, 95% concordance with a correlation coefficient of 0.9. The same specificity and sensitivity were achieved for comparison of results with published human sensitization data with a correlation coefficient of 0.91. The test also successfully identified nickel sulphate as a human skin sensitizer, which was misclassified as negative in the LLNA. In addition, sensitizers and non-sensitizers identified as positive or negative by the skin explant test have induced high/low T cell proliferation and IFNγ production, respectively. Collectively, the data suggests the human in-vitro skin explant test could provide the basis for a novel approach for characterization of the sensitizing activity as a first step in the risk assessment process. Copyright © 2015 John Wiley & Sons, Ltd.
Thress, Kenneth S; Brant, Roz; Carr, T Hedley; Dearden, Simon; Jenkins, Suzanne; Brown, Helen; Hammett, Tracey; Cantarini, Mireille; Barrett, J Carl
2015-12-01
To assess the ability of different technology platforms to detect epidermal growth factor receptor (EGFR) mutations, including T790M, from circulating tumor DNA (ctDNA) in advanced non-small cell lung cancer (NSCLC) patients. A comparison of multiple platforms for detecting EGFR mutations in plasma ctDNA was undertaken. Plasma samples were collected from patients entering the ongoing AURA trial (NCT01802632), investigating the safety, tolerability, and efficacy of AZD9291 in patients with EGFR-sensitizing mutation-positive NSCLC. Plasma was collected prior to AZD9291 dosing but following clinical progression on a previous EGFR-tyrosine kinase inhibitor (TKI). Extracted ctDNA was analyzed using two non-digital platforms (cobas(®) EGFR Mutation Test and therascreen™ EGFR amplification refractory mutation system assay) and two digital platforms (Droplet Digital™ PCR and BEAMing digital PCR [dPCR]). Preliminary assessment (38 samples) was conducted using all four platforms. For EGFR-TKI-sensitizing mutations, high sensitivity (78-100%) and specificity (93-100%) were observed using tissue as a non-reference standard. For the T790M mutation, the digital platforms outperformed the non-digital platforms. Subsequent assessment using 72 additional baseline plasma samples was conducted using the cobas(®) EGFR Mutation Test and BEAMing dPCR. The two platforms demonstrated high sensitivity (82-87%) and specificity (97%) for EGFR-sensitizing mutations. For the T790M mutation, the sensitivity and specificity were 73% and 67%, respectively, with the cobas(®) EGFR Mutation Test, and 81% and 58%, respectively, with BEAMing dPCR. Concordance between the platforms was >90%, showing that multiple platforms are capable of sensitive and specific detection of EGFR-TKI-sensitizing mutations from NSCLC patient plasma. The cobas(®) EGFR Mutation Test and BEAMing dPCR demonstrate a high sensitivity for T790M mutation detection. Genomic heterogeneity of T790M-mediated resistance may explain the reduced specificity observed with plasma-based detection of T790M mutations versus tissue. These data support the use of both platforms in the AZD9291 clinical development program. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Tacikowska, Małgorzata
2002-02-01
The aim of this study was to analyze the diagnostic usefulness of dynamic MRI with determination of the coefficient of enhancement rate and the character of tumor enhancement, and to assess both parameters in the differentiation of malignant lesions. The material consisted of 45 patients (30 sarcomas, 15 non-malignant lesions), age 16-64 years. MRI was done using an Elscint 2T unit, gradient echo techniques, apex angle 80 degrees. The repetition time (TR) was 80-200 ms, the echo time (TE) was 2-6 ms, 1 excitation; the acquisition time (TA) was 70-80 ms. The coefficient of tissue enhancement rate was calculated in the region of interest, and expressed as percent per second (erc%/s). The limit value of erc%/s was determined. The sensitivity and specificity of MRI were calculated in the differentiation of malignant tumors. The method of contrast filling of the tumors was assessed in successive phases after administration of gadolinium Gd-DTPA. Dynamic MRI with determination of the index of tumor enhancement rate is highly sensitive (93%) and specific (73%) in the differentiation of malignant and benign lesions. The usefulness of the assessment of tumor enhancement character was not confirmed, since the sensitivity and specificity were 73% and 33%. Dynamic MRI with determination of erc%/s and tumor enhancement character is highly sensitive (93%) and specific (87%). Dynamic MRI with determination of erc%/s and tumor enhancement character is the best method for differential diagnosis.
McMorrow, Meredith L.; Masanja, M. Irene; Abdulla, Salim M. K.; Kahigwa, Elizeus; Kachur, S. Patrick
2018-01-01
Rapid diagnostic tests (RDTs) represent an alternative to microscopy for malaria diagnosis and have shown high sensitivity and specificity in a variety of study settings. Current World Health Organization (WHO) guidelines for quality control of RDTs provide detailed instructions on pre-field testing, but offer little guidance for quality assurance once RDTs are deployed in health facilities. From September 2006 to April 2007, we introduced a histidine-rich protein II (HRP2)-based RDT (Paracheck) for suspected malaria cases five years of age and older in nine health facilities in Rufiji District, Tanzania, to assess sensitivity and specificity of RDTs in routine use at rural health facilities. Thick blood smears were collected for all patients tested with RDTs and stained and read by laboratory personnel in each facility. Thick smears were subsequently reviewed by a reference microscopist to determine RDT sensitivity and specificity. In all nine health facilities, there were significant problems with the quality of staining and microscopy. Sensitivity and specificity of RDTs were difficult to assess given the poor quality of routine blood smear staining. Mean operational sensitivity of RDTs based on reference microscopy was 64.8%, but varied greatly by health facility, range 18.8–85.9%. Sensitivity of RDTs increased with increasing parasite density. Specificity remained high at 87.8% despite relatively poor slide quality. Institution of quality control of RDTs based on poor quality blood smear staining may impede reliable measurement of sensitivity and specificity and undermine confidence in the new diagnostic. There is an urgent need for the development of alternative quality control procedures for rapid diagnostic tests that can be performed at the facility level. PMID:18784230
Validity, sensitivity and specificity of the mentation, behavior and mood subscale of the UPDRS.
Holroyd, Suzanne; Currie, Lillian J; Wooten, G Frederick
2008-06-01
The unified Parkinson's disease rating scale (UPDRS) is the most widely used tool to rate the severity and the stage of Parkinson's disease (PD). However, the mentation, behavior and mood (MBM) subscale of the UPDRS has received little investigation regarding its validity and sensitivity. Three items of this subscale were compared to criterion tests to examine validity, sensitivity and specificity. Ninety-seven patients with idiopathic PD were assessed on the UPDRS. Scores on three items of the MBM subscale, intellectual impairment, thought disorder and depression, were compared to criterion tests, the telephone interview for cognition status (TICS), psychiatric assessment for psychosis and the geriatric depression scale (GDS). Non-parametric tests of association were performed to examine concurrent validity of the MBM items. The sensitivities, specificities and optimal cutoff scores for each MBM item were estimated by receiver operating characteristic (ROC) curve analysis. The MBM items demonstrated low to moderate correlation with the criterion tests, and the sensitivity and specificity were not strong. Even using a score of 7.0 on the items of the MBM demonstrated a sensitivity/specificity of only 0.19/0.48 for intellectual impairment, 0.60/0.72 for thought disorder and 0.61/0.87 for depression. Using a more appropriate cutoff of 2.0 revealed sensitivities of 0.01, 0.38 and 0.13 respectively. The MBM subscale items of intellectual impairment, thought disorder and depression are not appropriate for screening or diagnostic purposes. Tools such as the TICS and the GDS should be considered instead.
Simple Nutrition Screening Tool for Pediatric Inpatients.
White, Melinda; Lawson, Karen; Ramsey, Rebecca; Dennis, Nicole; Hutchinson, Zoe; Soh, Xin Ying; Matsuyama, Misa; Doolan, Annabel; Todd, Alwyn; Elliott, Aoife; Bell, Kristie; Littlewood, Robyn
2016-03-01
Pediatric nutrition risk screening tools are not routinely implemented throughout many hospitals, despite prevalence studies demonstrating malnutrition is common in hospitalized children. Existing tools lack the simplicity of those used to assess nutrition risk in the adult population. This study reports the accuracy of a new, quick, and simple pediatric nutrition screening tool (PNST) designed to be used for pediatric inpatients. The pediatric Subjective Global Nutrition Assessment (SGNA) and anthropometric measures were used to develop and assess the validity of 4 simple nutrition screening questions comprising the PNST. Participants were pediatric inpatients in 2 tertiary pediatric hospitals and 1 regional hospital. Two affirmative answers to the PNST questions were found to maximize the specificity and sensitivity to the pediatric SGNA and body mass index (BMI) z scores for malnutrition in 295 patients. The PNST identified 37.6% of patients as being at nutrition risk, whereas the pediatric SGNA identified 34.2%. The sensitivity and specificity of the PNST compared with the pediatric SGNA were 77.8% and 82.1%, respectively. The sensitivity of the PNST at detecting patients with a BMI z score of less than -2 was 89.3%, and the specificity was 66.2%. Both the PNST and pediatric SGNA were relatively poor at detecting patients who were stunted or overweight, with the sensitivity and specificity being less than 69%. The PNST provides a sensitive, valid, and simpler alternative to existing pediatric nutrition screening tools such as Screening Tool for the Assessment of Malnutrition in Pediatrics (STAMP), Screening Tool Risk on Nutritional status and Growth (STRONGkids), and Paediatric Yorkhill Malnutrition Score (PYMS) to ensure the early detection of hospitalized children at nutrition risk. © 2014 American Society for Parenteral and Enteral Nutrition.
Kim, Daniel J; Francispragasam, Mario; Docherty, Gavin; Silver, Byron; Prager, Ross; Lee, Donna; Maberley, David
2018-05-18
Previous studies of point of care ultrasound (POCUS) have reported high sensitivities and specificities for retinal detachment (RD). Our primary objective was to assess the test characteristics of POCUS performed by a large heterogeneous group of emergency physicians (EPs) for the diagnosis of RD. This was a prospective diagnostic test assessment of POCUS performed by EPs with varying ultrasound experience on a convenience sample of emergency department (ED) patients presenting with flashes or floaters in one or both eyes. After standard ED assessment, EPs performed an ocular POCUS scan targeted to detect the presence or absence of RD. After completing their ED visit, all patients were assessed by a retina specialist who was blinded to the results of the POCUS scan. We calculated sensitivity and specificity with associated exact binomial confidence intervals (CI) using the retina specialist's final diagnosis as the reference standard. A total of 30 EPs enrolled 115 patients, with median age of 60 years and 64% female. The retina specialist diagnosed RD in 16 (14%) cases. The sensitivity and specificity of POCUS for detecting RD was 75% (95% CI 48%-93%) and 94% (95% CI 87%-98%), respectively. The positive likelihood ratio was 12.4 (95% CI 5.4-28.3), and negative likelihood ratio was 0.27 (95% CI 0.11-0.62). A large heterogeneous group of EPs can perform POCUS with high specificity but only intermediate sensitivity for RD. A negative POCUS scan in the ED performed by a heterogeneous group of providers after a one-hour POCUS didactic is not sufficiently sensitive to rule out RD in a patient with new onset flashes or floaters. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Garces, A; Jehan, I; Ditekemena, J; Phiri, M; Thorsten, V; Mazariegos, M; Chomba, E; Pasha, O; Tshefu, A; Wallace, D; McClure, EM; Goldenberg, RL; Carlo, WA; Wright, LL; Bose, C
2012-01-01
Abstract Objective To assess the feasibility of using birth attendants instead of bereaved mothers as perinatal verbal autopsy respondents. Methods Verbal autopsy interviews for early neonatal deaths and stillbirths were conducted separately among mothers (reference standard) and birth attendants in 38 communities in four developing countries. Concordance between maternal and attendant responses was calculated for all questions, for categories of questions and for individual questions. The sensitivity and specificity of individual questions with the birth attendant as respondent were assessed. Findings For early neonatal deaths, concordance across all questions was 94%. Concordance was at least 95% for more than half the questions on maternal medical history, birth attendance and neonate characteristics. Concordance on any given question was never less than 80%. Sensitivity and specificity varied across individual questions, more than 80% of which had a sensitivity of at least 80% and a specificity of at least 90%. For stillbirths, concordance across all questions was 93%. Concordance was 95% or greater more than half the time for questions on birth attendance, site of delivery and stillborn characteristics. Sensitivity and specificity varied across individual questions. Over 60% of the questions had a sensitivity of at least 80% and over 80% of them had a specificity of at least 90%. Overall, the causes of death established through verbal autopsy were similar, regardless of respondent. Conclusion Birth attendants can substitute for bereaved mothers as verbal autopsy respondents. The questions in existing harmonized verbal autopsy questionnaires need further refinement, as their sensitivity and specificity differ widely. PMID:22461715
Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.
2014-01-01
Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240
Promoter methylation of MCAM, ERα and ERβ in serum of early stage prostate cancer patients.
Brait, Mariana; Banerjee, Mithu; Maldonado, Leonel; Ooki, Akira; Loyo, Myriam; Guida, Elisa; Izumchenko, Evgeny; Mangold, Leslie; Humphreys, Elizabeth; Rosenbaum, Eli; Partin, Alan; Sidransky, David; Hoque, Mohammad Obaidul
2017-02-28
Prostate cancer (PC) is the second most common cancer among men worldwide. Currently, the most common non-invasive approach for screening and risk assessment of PC is measuring the level of serum prostate-specific antigen (PSA). However, the sensitivity of PSA is 42.8 % and specificity is 41.1%. As a result, the serum PSA test leads to numerous unneeded biopsies. Therefore, a rigorous search for biomarkers for early detection of PC is ongoing. In this study, we aim to assess a panel of epigenetic markers in an intend to develop an early detection test for PC. The sensitivity and specificity of hypermethylation of MCAM was 66% and 73% respectively which is an improvement from the sensitivity and specificity of PSA. Considering a combination marker panel of MCAM, ERα and ERβ increased the sensitivity to 75% and the specificity became 70% for the minimally invasive early detection test of PC. Sixteen primary matched tumor and serum were analyzed by quantitative methylation specific PCR (QMSP) to determine analytical and clinical sensitivity of the genes tested (SSBP2, MCAM, ERα, ERβ, APC, CCND2, MGMT, GSTP1, p16 and RARβ2). Additionally, serum samples from eighty four cases of PC, thirty controls and seven cases diagnosed as high grade Prostatic Intraepithelial Neoplasia (HGPIN) were analyzed. Promoter methylation of MCAM, ERα and ERβ have a potential to be utilized as biomarker for the early detection of prostate PC as their sensitivity and specificity seem to be better than serum PSA in our cohort of samples. After robust validation in a larger prospective cohort, our findings may reduce the numbers of unwarranted prostate biopsies.
Evaluation of echocardiography in the management of elderly patients with heart failure.
Hendry, A; Hacking, L; Langhorne, P; Vallance, R; MacDonald, J
1999-09-01
To determine the validity of a clinical diagnosis of systolic dysfunction in elderly patients with heart failure and assess the contribution of echocardiography to their management. 61 elderly patients with a diagnosis of heart failure in a geriatric assessment unit setting. Prospective study determining sensitivity, specificity and predictive values of a clinical and radiological diagnosis compared with echocardiographic standard. Proposed management was compared before and after echocardiography. Clinical assessment was highly sensitive (93%) but lacked specificity (32%). Combining radiological and clinical diagnoses increased specificity to 58%. Echocardiography revised the lead cardiac diagnosis for 28% of patients and influenced patient management plans for 41%. For elderly patients with heart failure, echocardiography improves diagnostic accuracy and identifies those patients with potential to benefit from angiotensin-converting enzyme inhibitors.
ERIC Educational Resources Information Center
Kerig, Patricia K.; Moeddel, Melissa Arnzen; Becker, Stephen P.
2011-01-01
This study investigated the sensitivity and specificity of the most widely used mental health screening instrument in juvenile detention, the Massachusetts Youth Screening Instrument (MAYSI-2), for detecting trauma and symptoms of posttraumatic stress disorder (PTSD) among detained youth. The MAYSI-2 scales measuring Substance Use,…
Lai, Y-C; Li, H-Y; Hung, C-S; Lin, M-S; Shih, S-R; Ma, W-Y; Hua, C-H; Chuang, L-M; Sung, F-C; Wei, J-N
2013-03-01
To evaluate whether homeostasis model assessment and high-sensitivity C-reactive protein improve the prediction of isolated post-load hyperglycaemia. The subjects were 1458 adults without self-reported diabetes recruited between 2006 and 2010. Isolated post-load hyperglycaemia was defined as fasting plasma glucose < 7 mmol/l and 2-h post-load plasma glucose ≥ 11.1 mmol/l. Risk scores of isolated post-load hyperglycaemia were constructed by multivariate logistic regression. An independent group (n = 154) was enrolled from 2010 to 2011 to validate the models' performance. One hundred and twenty-three subjects (8.28%) were newly diagnosed as having diabetes mellitus. Among those with undiagnosed diabetes, 64 subjects (52%) had isolated post-load hyperglycaemia. Subjects with isolated post-load hyperglycaemia were older, more centrally obese and had higher blood pressure, HbA(1c), fasting plasma glucose, triglycerides, LDL cholesterol, high-sensitivity C-reactive protein and homeostasis model assessment of insulin resistance and lower homeostasis model assessment of β-cell function than those without diabetes. The risk scores included age, gender, BMI, homeostasis model assessment, high-sensitivity C-reactive protein and HbA(1c). The full model had high sensitivity (84%) and specificity (87%) and area under the receiver operating characteristic curve (0.91), with a cut-off point of 23.81; validation in an independent data set showed 88% sensitivity, 77% specificity and an area under curve of 0.89. Over half of those with undiagnosed diabetes had isolated post-load hyperglycaemia. Homeostasis model assessment and high-sensitivity C-reactive protein are useful to identify subjects with isolated post-load hyperglycaemia, with improved performance over fasting plasma glucose or HbA(1c) alone. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.
Wu, Zheyang; Yang, Chun; Tang, Dalin
2011-06-01
It has been hypothesized that mechanical risk factors may be used to predict future atherosclerotic plaque rupture. Truly predictive methods for plaque rupture and methods to identify the best predictor(s) from all the candidates are lacking in the literature. A novel combination of computational and statistical models based on serial magnetic resonance imaging (MRI) was introduced to quantify sensitivity and specificity of mechanical predictors to identify the best candidate for plaque rupture site prediction. Serial in vivo MRI data of carotid plaque from one patient was acquired with follow-up scan showing ulceration. 3D computational fluid-structure interaction (FSI) models using both baseline and follow-up data were constructed and plaque wall stress (PWS) and strain (PWSn) and flow maximum shear stress (FSS) were extracted from all 600 matched nodal points (100 points per matched slice, baseline matching follow-up) on the lumen surface for analysis. Each of the 600 points was marked "ulcer" or "nonulcer" using follow-up scan. Predictive statistical models for each of the seven combinations of PWS, PWSn, and FSS were trained using the follow-up data and applied to the baseline data to assess their sensitivity and specificity using the 600 data points for ulcer predictions. Sensitivity of prediction is defined as the proportion of the true positive outcomes that are predicted to be positive. Specificity of prediction is defined as the proportion of the true negative outcomes that are correctly predicted to be negative. Using probability 0.3 as a threshold to infer ulcer occurrence at the prediction stage, the combination of PWS and PWSn provided the best predictive accuracy with (sensitivity, specificity) = (0.97, 0.958). Sensitivity and specificity given by PWS, PWSn, and FSS individually were (0.788, 0.968), (0.515, 0.968), and (0.758, 0.928), respectively. The proposed computational-statistical process provides a novel method and a framework to assess the sensitivity and specificity of various risk indicators and offers the potential to identify the optimized predictor for plaque rupture using serial MRI with follow-up scan showing ulceration as the gold standard for method validation. While serial MRI data with actual rupture are hard to acquire, this single-case study suggests that combination of multiple predictors may provide potential improvement to existing plaque assessment schemes. With large-scale patient studies, this predictive modeling process may provide more solid ground for rupture predictor selection strategies and methods for image-based plaque vulnerability assessment.
Gromisch, Elizabeth S; Portnoy, Jeffrey G; Foley, Frederick W
2018-05-15
Cognitive impairment is a prevalent and often intrusive problem among persons with multiple sclerosis (PwMS). Valid and reliable assessments, including quick screening measures, are crucial. The Brief International Cognitive Assessment for MS (BICAMS) was developed for this reason. While it lends itself to use in locations where formal neuropsychological resources might be limited, it does not include measures of verbal fluency or executive functioning, domains assessed as part of the Minimal Assessment of Cognitive Function in MS (MACFIMS). Given previous evidence that shortened MACFIMS measures have strong criterion validity, this study aimed to determine which of these should be included in the abbreviated MACFIMS (aMACFIMS), and how the aMACFIMS compares to the BICAMS. One hundred forty-seven PwMS were included in the analyses. A stepwise logistic regression was used to determine the measures in the aMACFIMS. Receiver-operating-characteristic (ROC) curves assessed the classification accuracy, sensitivity, and specificity. The batteries' sensitivity, specificity, and predictive values were then compared. Compared to the BICAMS, the final aMACFIMS had higher specificity (87% versus 72%) and positive predictive value (86% versus 77%), but lower sensitivity (71% versus 81%). The aMACFIMS has several benefits, including reduced administration time and the addition of a verbal fluency/executive functioning measure. Copyright © 2018 Elsevier B.V. All rights reserved.
Koneczny, Jarosław; Czekierdowski, Artur; Florczak, Marek; Poziemski, Paweł; Stachowicz, Norbert; Borowski, Dariusz
2017-01-01
Sonography based methods with various tumor markers are currently used to discriminate the type of adnexal masses. To compare the predictive value of selected sonography-based models along with subjective assessment in ovarian cancer prediction. We analyzed data of 271 women operated because of adnexal masses. All masses were verified by histological examination. Preoperative sonography was performed in all patients and various predictive models includ¬ing IOTA group logistic regression model LR1 (LR1), IOTA simple ultrasound-based rules by IOTA (SR), GI-RADS and risk of malignancy index (RMI3) were used. ROC curves were constructed and respective AUC's with 95% CI's were compared. Of 271 masses 78 proved to be malignant including 6 borderline tumors. LR1 had sensitivity of 91.0%, specificity of 91.2%, AUC = 0.95 (95% CI: 0.92-0.98). Sensitivity for GI-RADS for 271 patients was 88.5% with specificity of 85% and AUC = 0.91 (95% CI: 0.88-0.95). Subjective assessment yielded sensitivity and specificity of 85.9% and 96.9%, respectively with AUC = 0.97 (95% CI: 0.94-0.99). SR were applicable in 236 masses and had sensitivity of 90.6% with specificity of 95.3% and AUC = 0.93 (95% CI 0.89-0.97). RMI3 was calculated only in 104 women who had CA125 available and had sensitivity of 55.3%, specificity of 94% and AUC = 0.85 (95% CI: 0.77-0.93). Although subjective assessment by the ultrasound expert remains the best current method of adnexal tumors preoperative discrimination, the simplicity and high predictive value favor the IOTA SR method, and when not applicable, the IOTA LR1 or GI-RADS models to be primarily and effectively used.
Morgan, Catherine; Crowle, Cathryn; Goyen, Traci-Anne; Hardman, Caroline; Jackman, Michelle; Novak, Iona; Badawi, Nadia
2016-01-01
The aim of this study was to calculate the sensitivity and specificity of the General Movements Assessment (GMA) for estimating diagnostic accuracy in detecting cerebral palsy (CP) in an Australian context by a newly established NSW rater network. A prospective longitudinal cross-sectional study was conducted. The GMA was blind-rated from conventional video by two independent certified raters, blinded to medical history. A third rater resolved disagreements. High-risk population screening for CP using the GMA during the fidgety period (12-20 weeks) was carried out in four neonatal intensive care units and one CP service over a 30-month period (2012-2013). Participants were 259 high-risk infants. Sensitivity and specificity values were calculated with true positives defined as a confirmed diagnosis of CP from a medical doctor. Of the 259 infants assessed, 1-year follow-up data were available for 187. Of these, n = 48 had absent fidgety (high risk for CP), n = 138 had normal fidgety (low risk for CP), and n = 1 had abnormal fidgety (high risk for a neurological disorder). Of the 48 with absent fidgety movements, 39 had received a diagnosis of CP by 18 months and another 6 had an abnormal outcome. Of the n = 138 normal fidgety cases, n = 99 cases had a normal outcome, n = 38 had an abnormal outcome but not CP, and n = 1 had CP. For detecting CP, we had a sensitivity of 98% and specificity of 94%. GMA was feasible in an Australian context and accurately identified CP with a sensitivity and specificity comparable with European standards and published neuroimaging data. © 2015 The Authors. Journal of Paediatrics and Child Health © 2015 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
TESTS TO ASSESS SENSITIZATION TO ASPERGILLUS FUMIGATUS IN CYSTIC FIBROSIS
Aguiar, Simone Santana; Damaceno, Neiva; Forte, Wilma Carvalho Neves
2017-01-01
ABSTRACT Objective: To evaluate the results of the tests used to identify the IgE mediated sensitization to Aspergillus fumigatus in patients with cystic fibrosis. Methods: This is a cross-sectional descriptive study with a convenience sample of 86 patients diagnosed with cystic fibrosis in the Reference Service in Cystic Fibrosis at a tertiary teaching hospital. The following tests were performed to assess the sensitization to A. fumigatus in patients with cystic fibrosis: Total serum IgE, eosinophil count, fungus detection through oropharyngeal swab or sputum culture, serum-specific IgE, and immediate-type hypersensitivity (IgE) skin tests. We compared the results of the different tests performed. Results: In 33 (38.4%) patients with cystic fibrosis, with ages ranging from 1 to 33 years (median of 8 years), the IgE-mediated A. fumigatus sensitization test results were: in 16 patients, there was an increase in serum-specific IgE (>0.35 kU/L); in 23, skin tests were positive; and six had sensitization in both tests. We observed two patients with eosinophilia (>1,000 eosinophils/mm3) and seven with increasing total serum IgE (>1,000 IU/mL), all of whom obtained negative results in skin tests and had no IgE increase specific to A. fumigatus. A. fumigatus was not detected in oropharyngeal swabs and/or sputum culture of any patients. Conclusions: We conclude that, among the tests used to assess sensitization to A. fumigatus in cystic fibrosis patients, both serum-specific IgE and immediate-type hypersensitivity (IgE) skin tests are required. Serum eosinophilia and respiratory secretion culture were not essential in this study. PMID:28977288
Thong, Kai Shin; Chee, Kok Yoon; Ng, Chong Guan; Walterfang, Mark; Velakoulis, Dennis
2016-09-01
This study aims to establish psychometric properties of the Malay Neuropsychiatry Unit Cognitive Assessment Tool (Malay NuCOG) in Alzheimer's disease. NuCOG was translated to Malay language and compared with Montreal Cognitive Assessment Tool on 80 individuals. The Malay NuCOG showed good internal consistency and reliability (Cronbach's alpha = 0.895). It demonstrated 100% sensitivity and 87.5% specificity at the cutoff score of 78.50/100. The Malay NuCOG is a valid and reliable cognitive instrument that is sensitive and specific for the detection of dementia and has clinical advantages in its ability to examine individual cognitive domains. © 2015 Wiley Publishing Asia Pty Ltd.
Ebner, Matthias; Birschmann, Ingvild; Peter, Andreas; Härtig, Florian; Spencer, Charlotte; Kuhn, Joachim; Blumenstock, Gunnar; Zuern, Christine S; Ziemann, Ulf; Poli, Sven
2017-09-01
In patients receiving direct oral anticoagulants (DOACs), emergency treatment like thrombolysis for acute ischemic stroke is complicated by insufficient availability of DOAC-specific coagulation tests. Conflicting recommendations have been published concerning the use of global coagulation assays for ruling out relevant DOAC-induced anticoagulation. Four hundred eighty-one samples from 96 DOAC-treated patients were tested using prothrombin time (PT), activated partial thromboplastin time (aPTT) and thrombin time (TT), DOAC-specific assays (anti-Xa activity, diluted TT), and liquid chromatography-tandem mass spectrometry. Sensitivity and specificity of test results to identify DOAC concentrations <30 ng/mL were calculated. Receiver operating characteristic analyses were used to define reagent-specific cutoff values. Normal PT and aPTT provide insufficient specificity to safely identify DOAC concentrations <30 ng/mL (rivaroxaban/PT: specificity, 77%/sensitivity, 94%; apixaban/PT: specificity, 13%/sensitivity, 94%, dabigatran/aPTT: specificity, 49%/sensitivity, 91%). Normal TT was 100% specific for dabigatran, but sensitivity was 26%. In contrast, reagent-specific PT and aPTT cutoffs provided >95% specificity and a specific TT cutoff enhanced sensitivity for dabigatran to 84%. For apixaban, no cutoffs could be established. Even if highly DOAC-reactive reagents are used, normal results of global coagulation tests are not suited to guide emergency treatment: whereas normal PT and aPTT lack specificity to rule out DOAC-induced anticoagulation, the low sensitivity of normal TT excludes the majority of eligible patients from treatment. However, reagent-specific cutoffs for global coagulation tests ensure high specificity and optimize sensitivity for safe emergency decision making in rivaroxaban- and dabigatran-treated patients. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT02371044 and NCT02371070. © 2017 American Heart Association, Inc.
Shamim, Faisal; Ullah, Hameed; Khan, Fauzia A.
2015-01-01
Background: Several measurement tools have been used for assessment of postoperative pain in pediatric patients. Self-report methods have limitations in younger children and parent, nurse or physician assessment can be used as a surrogate measure. These tools should be tested in different cultures as pain can be influenced by sociocultural factors. The objective was to assess the inter-rater agreement on four different behavioral pain assessment scales in our local population. Materials and Methods: This prospective, descriptive, observational study was conducted in Pakistan. American Society of Anesthesiologists I and II children, 3-7 years of age, undergoing elective surgery were enrolled. Four pain assessment scales were used, Children's Hospital of Eastern Ontario Pain Scale (CHEOPS), Toddler Preschool Postoperative Pain Scale (TPPPS), objective pain scale (OPS), and Face, Legs, Activity, Cry, Consolability (FLACC). After 15 and 60 min of arrival in the postanesthesia care unit (PACU), each child evaluated his/her postoperative pain by self-reporting and was also independently assessed by the PACU nurse, PACU anesthetist and the parent. The sensitivity and specificity of the responses of the four pain assessment scales were compared to the response of the child. Results: At 15 min, sensitivity and specificity were >60% for doctors and nurses on FLACC, OPS, and CHEOPS scales and for FLACC and CHEOPS scale for the parents. Parents showed poor agreement on OPS and TPPS. At 60 min, sensitivity was poor on the OPS scale by all three observers. Nurses showed a lower specificity on FLACC tool. Parents had poor specificity on CHEOPS and rate of false negatives was high with TPPS. Conclusions: We recommend the use of FLACC scale for assessment by parents, nurses, and doctors in Pakistani children aged between 3 and 7. PMID:25829906
ADHD Diagnosis: As Simple As Administering a Questionnaire or a Complex Diagnostic Process?
Parker, Ashton; Corkum, Penny
2016-06-01
The present study investigated the validity of using the Conners' Teacher and Parent Rating Scales (CTRS/CPRS) or semistructured diagnostic interviews (Parent Interview for Child Symptoms and Teacher Telephone Interview) to predict a best-practices clinical diagnosis of ADHD. A total of 279 children received a clinical diagnosis based on a best-practices comprehensive assessment (including diagnostic parent and teacher interviews, collection of historical information, rating scales, classroom observations, and a psychoeducational assessment) at a specialty ADHD Clinic in Truro, Nova Scotia, Canada. Sensitivity and specificity with clinical diagnosis were determined for the ratings scales and diagnostic interviews. Sensitivity and specificity values were high for the diagnostic interviews (91.8% and 70.7%, respectively). However, while sensitivity of the CTRS/CPRS was relatively high (83.5%), specificity was poor (35.7%). The low specificity of the CPRS/CTRS is not sufficient to be used alone to diagnose ADHD. (J. of Att. Dis. 2016; 20(6) 478-486). © The Author(s) 2013.
Bot, M; Middeldorp, C M; de Geus, E J C; Lau, H M; Sinke, M; van Nieuwenhuizen, B; Smit, J H; Boomsma, D I; Penninx, B W J H
2017-01-01
There is a paucity of valid, brief instruments for the assessment of lifetime major depressive disorder (MDD) that can be used in, for example, large-scale genomics, imaging or biomarker studies on depression. We developed the LIfetime Depression Assessment Self-report (LIDAS), which assesses lifetime MDD diagnosis according to DSM criteria, and is largely based on the widely used Composite International Diagnostic Interview (CIDI). Here, we tested the feasibility and determined the sensitivity and specificity for measuring lifetime MDD with this new questionnaire, with a regular CIDI as reference. Sensitivity and specificity analyses of the online lifetime MDD questionnaire were performed in adults with (n = 177) and without (n = 87) lifetime MDD according to regular index CIDIs, selected from the Netherlands Study of Depression and Anxiety (NESDA) and Netherlands Twin Register (NTR). Feasibility was tested in an additional non-selective, population-based sample of NTR participants (n = 245). Of the 753 invited persons, 509 (68%) completed the LIDAS, of which 419 (82%) did this online. User-friendliness of the instrument was rated high. Median completion time was 6.2 min. Sensitivity and specificity for lifetime MDD were 85% [95% confidence interval (CI) 80-91%] and 80% (95% CI 72-89%), respectively. This LIDAS instrument gave a lifetime MDD prevalence of 20.8% in the population-based sample. Measuring lifetime MDD with an online instrument was feasible. Sensitivity and specificity were adequate. The instrument gave a prevalence of lifetime MDD in line with reported population prevalences. LIDAS is a promising tool for rapid determination of lifetime MDD status in large samples, such as needed for genomics studies.
Smith, Toby O; Simpson, Michael; Ejindu, Vivian; Hing, Caroline B
2013-04-01
The purpose of this study was to assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and multidetector arrays in CT arthrography (MDCT) for assessing chondral lesions in the hip joint. A review of the published and unpublished literature databases was performed to identify all studies reporting the diagnostic test accuracy (sensitivity/specificity) of MRI, MRA or MDCT for the assessment of adults with chondral (cartilage) lesions of the hip with surgical comparison (arthroscopic or open) as the reference test. All included studies were reviewed using the quality assessment of diagnostic accuracy studies appraisal tool. Pooled sensitivity, specificity, likelihood ratios and diagnostic odds ratios were calculated with 95 % confidence intervals using a random-effects meta-analysis for MRI, MRA and MDCT imaging. Eighteen studies satisfied the eligibility criteria. These included 648 hips from 637 patients. MRI indicated a pooled sensitivity of 0.59 (95 % CI: 0.49-0.70) and specificity of 0.94 (95 % CI: 0.90-0.97), and MRA sensitivity and specificity values were 0.62 (95 % CI: 0.57-0.66) and 0.86 (95 % CI: 0.83-0.89), respectively. The diagnostic test accuracy for the detection of hip joint cartilage lesions is currently superior for MRI compared with MRA. There were insufficient data to perform meta-analysis for MDCT or CTA protocols. Based on the current limited diagnostic test accuracy of the use of magnetic resonance or CT, arthroscopy remains the most accurate method of assessing chondral lesions in the hip joint.
Keezer, Mark R; Bouma, Hanni K; Wolfson, Christina
2014-11-01
To describe the diagnostic accuracy of screening questionnaires to identify epilepsy in adults, we performed a systematic review of diagnostic studies that assessed the sensitivity and specificity of such screening questionnaires as compared to a physician's clinical assessment. We searched Ovid MEDLINE (1946 to present) and Ovid EMBASE (1947 to present) for studies that estimated the sensitivity and specificity of nonphysician administered screening questionnaires for adults with epilepsy. Both telephone and in-person administered questionnaires were included, whether applied to population or hospital/clinic-based cohorts. The risk of bias was assessed using the Quality Assessment of Diagnostic Studies-2 (QUADAS-2) tool. Our initial search strategy resulted in 917 records. We found nine studies eligible for inclusion. The estimated sensitivity and specificity of the questionnaires used to identify persons with a lifetime history of epilepsy ranged from 81.5% to 100% and 65.6% to 99.2%, respectively. The sensitivity and specificity of these questionnaires in identifying persons with active epilepsy ranged from 48.6% to 100% and 73.9% to 99.9%, respectively. Overall we found a high risk of bias in patient selection and study flow in the majority of studies. We identified nine validation studies of epilepsy screening questionnaires, summarized their study characteristics, presented their results, and performed a rigorous quality assessment. This review serves as a basis for future studies by providing a systematic review of existing work. Future research addressing previous limitations will ultimately allow us to more accurately estimate the burden and risk of epilepsy in the general population. Wiley Periodicals, Inc. © 2014 International League Against Epilepsy.
Prediction of venous wound healing with laser speckle imaging.
van Vuuren, Timme Maj; Van Zandvoort, Carina; Doganci, Suat; Zwiers, Ineke; tenCate-Hoek, Arina J; Kurstjens, Ralph Lm; Wittens, Cees Ha
2017-12-01
Introduction Laser speckle imaging is used for noninvasive assessment of blood flow of cutaneous wounds. The aim of this study was to assess if laser speckle imaging can be used as a predictor of venous ulcer healing. Methods After generating the flux speckle images, three regions of interest (ROI) were identified to measure the flow. Sensitivity, specificity, negative predictive value, and positive predictive value for ulcer healing were calculated. Results In total, 17 limbs were included. A sensitivity of 92.3%, specificity of 75.0%, PPV of 80.0%, and NPV 75.0% were found in predicting wound healing based on laser speckle images. Mean flux values were lowest in the center (ROI I) and showed an increase at the wound edge (ROI II, p = 0.03). Conclusion Laser speckle imaging shows acceptable sensitivity and specificity rates in predicting venous ulcer healing. The wound edge proved to be the best probability for the prediction of wound healing.
A Nonword Repetition Task to Assess Bilingual Children's Phonology
ERIC Educational Resources Information Center
dos Santos, Christophe; Ferré, Sandrine
2018-01-01
Children with specific language impairment (SLI) are particularly sensitive to phonological complexity in their language. Their performance drops when there are specific phonological structures or when complexity increases. A nonword repetition (NWR) test, which aims to assess the phonology of bilingual speakers with and without SLI, should…
Hartman, Esther A R; van Royen-Kerkhof, Annet; Jacobs, Johannes W G; Welsing, Paco M J; Fritsch-Stork, Ruth D E
2018-03-01
To evaluate the performance in classifying systemic lupus erythematosus by the 2012 Systemic Lupus International Collaborating Clinics criteria (SLICC'12), versus the revised American College of Rheumatology criteria from 1997 (ACR'97) in adult and juvenile SLE patients. A systematic literature search was conducted in PubMed and Embase for studies comparing SLICC'12 and ACR'97 with clinical diagnosis. A meta-analysis was performed to estimate the sensitivity and specificity of SLICC'12 and ACR'97. To assess classification earlier in the disease by either set, sensitivity and specificity were compared for patients with disease duration <5years. Sensitivity and specificity of individual criteria items were also assessed. In adult SLE (nine studies: 5236 patients, 1313 controls), SLICC'12 has higher sensitivity (94.6% vs. 89.6%) and similar specificity (95.5% vs. 98.1%) compared to ACR'97. For juvenile SLE (four studies: 568 patients, 339 controls), SLICC'12 demonstrates higher sensitivity (99.9% vs. 84.3%) than ACR'97, but much lower specificity (82.0% vs. 94.1%). SLICC'12 classifies juvenile SLE patients earlier in disease course. Individual items contributing to diagnostic accuracy are low complement, anti-ds DNA and acute cutaneous lupus in SLICC'12, and the immunologic and hematologic disorder in ACR'97. Based on sensitivity and specificity SLICC'12 is best for adult SLE. Following the view that higher specificity, i.e. avoidance of false positives, is preferable, ACR'97 is best for juvenile SLE even if associated with lower sensitivity. Our results on the contribution of the individual items of SLICC'12 and ACR´97 may be of value in future efforts to update classification criteria. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Assessing behavioural changes in ALS: cross-validation of ALS-specific measures.
Pinto-Grau, Marta; Costello, Emmet; O'Connor, Sarah; Elamin, Marwa; Burke, Tom; Heverin, Mark; Pender, Niall; Hardiman, Orla
2017-07-01
The Beaumont Behavioural Inventory (BBI) is a behavioural proxy report for the assessment of behavioural changes in ALS. This tool has been validated against the FrSBe, a non-ALS-specific behavioural assessment, and further comparison of the BBI against a disease-specific tool was considered. This study cross-validates the BBI against the ALS-FTD-Q. Sixty ALS patients, 8% also meeting criteria for FTD, were recruited. All patients were evaluated using the BBI and the ALS-FTD-Q, completed by a carer. Correlational analysis was performed to assess construct validity. Precision, sensitivity, specificity, and overall accuracy of the BBI when compared to the ALS-FTD-Q, were obtained. The mean score of the whole sample on the BBI was 11.45 ± 13.06. ALS-FTD patients scored significantly higher than non-demented ALS patients (31.6 ± 14.64, 9.62 ± 11.38; p < 0.0001). A significant large positive correlation between the BBI and the ALS-FTD-Q was observed (r = 0.807, p < 0.0001), and no significant correlations between the BBI and other clinical/demographic characteristics indicate good convergent and discriminant validity, respectively. 72% of overall concordance was observed. Precision, sensitivity, and specificity for the classification of severely impaired patients were adequate. However, lower concordance in the classification of mild behavioural changes was observed, with higher sensitivity using the BBI, most likely secondary to BBI items which endorsed behavioural aspects not measured by the ALS-FTD-Q. Good construct validity has been further confirmed when the BBI is compared to an ALS-specific tool. Furthermore, the BBI is a more comprehensive behavioural assessment for ALS, as it measures the whole behavioural spectrum in this condition.
McCarthy, Michael D; Thompson, Sanna J; Knox, Kerry L
2012-03-01
Military members are required to complete the Post-Deployment Health Assessment on return from deployment and the Post-Deployment Health Reassessment (PHDRA) 90 to 180 days later, and we assessed the PDHRA's sensitivity and specificity in identifying posttraumatic stress disorder (PTSD) and depression after a military deployment among US Air Force personnel. We computed the PDHRA's sensitivity and specificity for depression and PTSD and developed a structural model to suggest possible improvements to it. For depression, sensitivity and specificity were 0.704 and 0.651, respectively; for PTSD, they were 0.774 and 0.650, respectively. Several variables produced significant direct effects on depression and trauma, suggesting that modifications could increase its sensitivity and specificity. The PDHRA was moderately effective in identifying airmen with depression and PTSD. It identified behavioral health concerns in many airmen who did not develop a diagnostic mental health condition. Its low level of specificity may result in reduced barriers to care and increased support services, key components of a public health approach to suicide prevention, for airmen experiencing subacute levels of distress after deployment, which may, in part, account for lower suicide rates among airmen after deployment.
The Brief Early Childhood Screening Assessment: Preliminary Validity in Pediatric Primary Care.
Fallucco, Elise M; Wysocki, Tim; James, Lauren; Kozikowski, Chelsea; Williams, Andre; Gleason, Mary M
Brief, well-validated instruments are needed to facilitate screening for early childhood behavioral and emotional problems (BEPs). The objectives of this study were to empirically reduce the length of the Early Childhood Screening Assessment (ECSA) and to assess the validity and reliability of this shorter tool. Using caregiver ECSA responses for 2467 children aged 36 to 60 months seen in primary care, individual ECSA items were ranked on a scale ranging from "absolutely retain" to "absolutely delete." Items were deleted sequentially beginning with "absolutely delete" and going up the item prioritization list, resulting in 35 shorter versions of the ECSA. A separate primary care sample (n = 69) of mothers of children aged 18 to 60 months was used to determine the sensitivity and specificity of each shorter ECSA version using psychiatric diagnosis on the Diagnostic Infant and Preschool Assessment as the gold standard. The version with the optimal balance of sensitivity, specificity, and length was selected as the Brief ECSA. Associations between Brief ECSA scores and other pertinent measures were evaluated to estimate reliability and validity. A 22-item measure reflected the best combination of brevity, sensitivity and specificity. A cutoff score of 9 or higher on the 22-item Brief ECSA demonstrated acceptable sensitivity (89%) and specificity (85%) for predicting a psychiatric diagnosis. Brief ECSA scores correlated significantly and in expected directions with scores on pertinent measures and with demographic variables. The results indicate that the Brief ECSA has sound psychometric properties for identifying young children with BEPs in primary care.
ERIC Educational Resources Information Center
DeSousa, Diogo Araujo; Salum, Giovanni Abrahao; Isolan, Luciano Rassier; Manfro, Gisele Gus
2013-01-01
The aim of this cross-sectional community-based study was to examine the sensitivity and specificity of the Screen for Child Anxiety Related Emotional Disorders (SCARED) to the diagnosis of anxiety disorders (AD). Participants were 119 students aged 9-18. Psychiatric diagnoses were assessed by a psychiatrist throughout a structural clinical…
Pulford, Justin; Siba, Peter M; Mueller, Ivo; Hetzel, Manuel W
2014-12-03
This paper aims to assess the sensitivity and specificity of exit interviews as a measure of malaria case management practice as compared to direct observation. The malaria case management of 1654 febrile patients attending 110 health facilities from across Papua New Guinea was directly observed by a trained research officer as part of a repeat cross sectional survey. Patient recall of 5 forms of clinical advice and 5 forms of clinical action were then assessed at service exit and statistical analyses on matched observation/exit interview data conducted. The sensitivity of exit interviews with respect to clinical advice ranged from 36.2% to 96.4% and specificity from 53.5% to 98.6%. With respect to clinical actions, sensitivity of the exit interviews ranged from 83.9% to 98.3% and specificity from 70.6% to 98.1%. The exit interview appears to be a valid measure of objective malaria case management practices such as the completion of a diagnostic test or the provision of antimalarial medication, but may be a less valid measure of low frequency, subjective practices such as the provision of malaria prevention advice.
A proposed cutoff point of waist-to-height ratio for metabolic risk in African township adolescents.
Kruger, H Salome; Faber, Mieke; Schutte, Aletta E; Ellis, Suria M
2013-03-01
A waist:height ratio (WHtR) higher than 0.5 has been proposed as a cutoff point for abdominal obesity in both sexes and at all ages. It is unknown if this cutoff point is appropriate for previously undernourished adolescents. We assessed the cutoff value of the WHtR associated with an increased metabolic risk in 178 black South African 14- to 18-y-old adolescents (69 boys, 109 girls). We measured weight, height, waist circumference, fasting plasma glucose and insulin levels, serum high-sensitivity C-reactive protein, and blood pressure and calculated the WHtR and homeostasis model assessment of insulin resistance (HOMA-IR). Using receiver operating characteristics curve analyses, we assessed the WHtR with the highest sensitivity and specificity to discriminate adolescents with increased fasting plasma glucose, HOMA-IR, serum high-sensitivity C-reactive protein, and blood pressure from those with "normal" values. The WHtR cutoff points derived from the receiver operating characteristics curves ranged from 0.40 to 0.41, with best diagnostic value at 0.41. A WHtR of 0.40 had 80% sensitivity and 38.5% specificity to classify adolescents with fasting blood glucose level higher than 5.6 mmol/L (area under the curve [AUC] 0.57). A WHtR of 0.41 had 64% sensitivity and 58.5% specificity for a HOMA-IR higher than 3.4 (AUC 0.66), 55% sensitivity and 55.6% specificity for a high-sensitivity C-reactive protein level higher than 1 mg/L (AUC 0.57), and 64% sensitivity and 50.2% specificity for a blood pressure higher than the age-, sex-, and height-specific 90th percentiles (AUC 0.56). Adolescents with a WHtR higher than 0.41 had an odds ratio of 2.46 (95% confidence interval 0.96-6.30) for having a HOMA-IR higher than 3.4. The WHtR cutoff to indicate metabolic risk for black South African adolescents is 0.41, which is lower than the proposed international cutoff of 0.5. The WHtR can be used for screening adolescents with components of the metabolic syndrome in intervention programs. Copyright © 2013 Elsevier Inc. All rights reserved.
Bittner, Mario; Faes, Livia; Boehni, Sophie C; Bachmann, Lucas M; Schlingemann, Reinier O; Schmid, Martin K
2016-12-07
Colour Doppler analysis of ophthalmic vessels has been proposed as a promising tool in the diagnosis of various eye diseases, but the available diagnostic evidence has not yet been assessed systematically. We performed a comprehensive systematic review of the literature on the diagnostic properties of Colour Doppler imaging (CDI) assessing ophthalmic vessels and provide an inventory of the available evidence. Eligible papers were searched electronically in (Pre) Medline, Embase and Scopus, and via cross-checking of reference lists. The minimum requirement to be included was the availability of original data and the possibility to construct a two-by-two table. Study selection, critical appraisal using the QUADAS II instrument and extraction of salient study characteristics was made in duplicate. Sensitivity and specificity was computed for each study. We included 11 studies (15 two-by-two tables) of moderate methodological quality enrolling 820 participants (range 30 to 118). In 44.4% participants were female (range 37-59% in specific subgroups). CDI was assessed for internal carotid stenosis, diabetic retinopathy, glaucoma, and branch or central retinal vein occlusion diagnosis. There was insufficient data to pool the results for specific illnesses. For the assessments of ophthalmic arteries, mean sensitivity was 0.69 (range 0.27-0.96) with a corresponding mean specificity of 0.83 (range 0.70-0.96). Mean sensitivity of the central retinal artery assessments was 0.58 (range 0.31-0.84) and the corresponding mean specificity was 0.82 (range 0.63-0.94). Robust assessments of the diagnostic value of colour Doppler analysis remain uncommon, limiting the possibilities to extrapolate its true potential for clinical practice. PROSPERO 2014:CRD42014014027.
Balhara, Yatan Pal Singh; Jain, Raka
2013-01-01
Tobacco use has been associated with various carcinomas including lung, esophagus, larynx, mouth, throat, kidney, bladder, pancreas, stomach, and cervix. Biomarkers such as concentration of cotinine in the blood, urine, or saliva have been used as objective measures to distinguish nonusers and users of tobacco products. A change in the cut-off value of urinary cotinine to detect active tobacco use is associated with a change in sensitivity and sensitivity of detection. The current study aimed at assessing the impact of using different cut-off thresholds of urinary cotinine on sensitivity and specificity of detection of smoking and smokeless tobacco product use among psychiatric patients. All the male subjects attending the psychiatry out-patient department of the tertiary care multispecialty teaching hospital constituted the sample frame for the current study in a cross-sectionally. Quantitative urinary cotinine assay was done by using ELISA kits of Calbiotech. Inc., USA. We used the receiver operating characteristic (ROC) curve to assess the sensitivity and specificity of various cut-off values of urinary cotinine to identify active smokers and users of smokeless tobacco products. ROC analysis of urinary cotinine levels in detection of self-reported smoking provided the area under curve (AUC) of 0.434. Similarly, the ROC analysis of urinary cotinine levels in detection of self-reported smoking revealed AUC of 0.44. The highest sensitivity and specificity of 100% for smoking were detected at the urinary cut-off value greater than or equal to 2.47 ng/ml. The choice of cut-off value of urinary cotinine used to distinguish nonusers form active users of tobacco products impacts the sensitivity as well as specificity of detection.
Development and Validation of the Pediatric Medical Complexity Algorithm (PMCA) Version 3.0.
Simon, Tamara D; Haaland, Wren; Hawley, Katherine; Lambka, Karen; Mangione-Smith, Rita
2018-02-26
To modify the Pediatric Medical Complexity Algorithm (PMCA) to include both International Classification of Diseases, Ninth and Tenth Revisions, Clinical Modification (ICD-9/10-CM) codes for classifying children with chronic disease (CD) by level of medical complexity and to assess the sensitivity and specificity of the new PMCA version 3.0 for correctly identifying level of medical complexity. To create version 3.0, PMCA version 2.0 was modified to include ICD-10-CM codes. We applied PMCA version 3.0 to Seattle Children's Hospital data for children with ≥1 emergency department (ED), day surgery, and/or inpatient encounter from January 1, 2016, to June 30, 2017. Starting with the encounter date, up to 3 years of retrospective discharge data were used to classify children as having complex chronic disease (C-CD), noncomplex chronic disease (NC-CD), and no CD. We then selected a random sample of 300 children (100 per CD group). Blinded medical record review was conducted to ascertain the levels of medical complexity for these 300 children. The sensitivity and specificity of PMCA version 3.0 was assessed. PMCA version 3.0 identified children with C-CD with 86% sensitivity and 86% specificity, children with NC-CD with 65% sensitivity and 84% specificity, and children without CD with 77% sensitivity and 93% specificity. PMCA version 3.0 is an updated publicly available algorithm that identifies children with C-CD, who have accessed tertiary hospital emergency department, day surgery, or inpatient care, with very good sensitivity and specificity when applied to hospital discharge data and with performance to earlier versions of PMCA. Copyright © 2018 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Tursi, Antonio; Elisei, Walter; Picchio, Marcello; Giorgetti, GianMarco; Brandimarte, Giovanni
2015-05-01
Anti-TNFα antibodies are effective in treating inflammatory bowel diseases (IBDs) unresponsive to the standard treatments. Information about the role of rapid fecal calprotectin (FC) in monitoring ambulatory IBD patients under treatment with anti-TNFα is lacking. Our aim was to assess the accuracy of rapid FC in monitoring those patients. Seventy-two patients (38 males, 34 females, mean age 42.5 years, range 23-57 years), affected by ulcerative colitis (UC) (20 patients) or by Crohn's disease (CD) (52 patients) were treated with anti-TNFα antibodies. FC was assessed by a rapid semiquantitative test. With respect to the absence of clinical remission, FC test showed sensitivity of 71.8 %, specificity of 65.2 %, PPV of 41.8 %, and NPV of 86.9 %. In UC patients, FC test showed a sensitivity of 66.7 %, a specificity of 56.1 %, a PPV of 18.2 %, and a NPV of 92.0 %. In CD patients, FC test showed sensitivity of 70.6 %, specificity of 65.2 %, PPV of 50.0 %, and NPV of 81.8 %. With respect to the presence of endoscopic lesions, FC test showed sensitivity of 73.5 %, specificity of 96.0 %, PPV of 96.2 %, and NPV of 72.7 %. In UC patients, FC test showed sensitivity of 47.2 %, specificity of 84.6 %, PPV of 89.5 %, and NPV of 36.7 %. In CD patients, FC test showed sensitivity of 90.1 %, specificity of 79.7 %, PPV of 71.9 %, and NPV of 93.3 %. Diagnostic accuracy of rapid FC seems better in predicting persistence of endoscopic lesions than clinical remission in IBD patients under treatment with anti-TNFα.
Richardson, Michael L; Petscavage, Jonelle M
2011-11-01
The sensitivity and specificity of magnetic resonance imaging (MRI) for diagnosis of meniscal tears has been studied extensively, with tears usually verified by surgery. However, surgically unverified cases are often not considered in these studies, leading to verification bias, which can falsely increase the sensitivity and decrease the specificity estimates. Our study suggests that such bias may be very common in the meniscal MRI literature, and illustrates techniques to detect and correct for such bias. PubMed was searched for articles estimating sensitivity and specificity of MRI for meniscal tears. These were assessed for verification bias, deemed potentially present if a study included any patients whose MRI findings were not surgically verified. Retrospective global sensitivity analysis (GSA) was performed when possible. Thirty-nine of the 314 studies retrieved from PubMed specifically dealt with meniscal tears. All 39 included unverified patients, and hence, potential verification bias. Only seven articles included sufficient information to perform GSA. Of these, one showed definite verification bias, two showed no bias, and four others showed bias within certain ranges of disease prevalence. Only 9 of 39 acknowledged the possibility of verification bias. Verification bias is underrecognized and potentially common in published estimates of the sensitivity and specificity of MRI for the diagnosis of meniscal tears. When possible, it should be avoided by proper study design. If unavoidable, it should be acknowledged. Investigators should tabulate unverified as well as verified data. Finally, verification bias should be estimated; if present, corrected estimates of sensitivity and specificity should be used. Our online web-based calculator makes this process relatively easy. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Park, Su San; Lee, Ju Yul; Cho, Sung-Il
2007-07-01
We investigated the validity of the dipstick method (Mossman Associates Inc. USA) and the expired CO method to distinguish between smokers and nonsmokers. We also elucidated the related factors of the two methods. This study included 244 smokers and 50 ex-smokers, recruited from smoking cessation clinics at 4 local public health centers, who had quit for over 4 weeks. We calculated the sensitivity, specificity and Kappa coefficient of each method for validity. We obtained ROC curve, predictive value and agreement to determine the cutoff of expired air CO method. Finally, we elucidated the related factors and compared their effect powers using the standardized regression coefficient. The dipstick method showed a sensitivity of 92.6%, specificity of 96.0% and Kappa coefficient of 0.79. The best cutoff value to distinguish smokers was 5-6 ppm. At 5 ppm, the expired CO method showed a sensitivity of 94.3%, specificity of 82.0% and Kappa coefficient of 0.73. And at 6 ppm, sensitivity, specificity and Kappa coefficient were 88.5%, 86.0% and 0.64, respectively. Therefore, the dipstick method had higher sensitivity and specificity than the expired CO method. The dipstick and expired CO methods were significantly increased with increasing smoking amount. With longer time since the last smoking, expired CO showed a rapid decrease after 4 hours, whereas the dipstick method showed relatively stable levels for more than 4 hours. The dipstick and expired CO methods were both good indicators for assessing smoking status. However, the former showed higher sensitivity and specificity and stable levels over longer hours after smoking, compared to the expired CO method.
Fluorescence-based assay as a new screening tool for toxic chemicals
Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey
2016-01-01
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients. PMID:27653274
Fluorescence-based assay as a new screening tool for toxic chemicals.
Moczko, Ewa; Mirkes, Evgeny M; Cáceres, César; Gorban, Alexander N; Piletsky, Sergey
2016-09-22
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Fluorescence-based assay as a new screening tool for toxic chemicals
NASA Astrophysics Data System (ADS)
Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey
2016-09-01
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup
2018-01-01
The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.
Cianfarani, Stefano; Tondinelli, Tiziana; Spadoni, Gian Luigi; Scirè, Giuseppe; Boemi, Sergio; Boscherini, Brunetto
2002-08-01
The diagnosis of GH insufficiency (GHI) in childhood is not straightforward. Our aim was to test the sensitivity and specificity of height velocity (HV), IGF-I, IGFBP-3 and GH stimulation tests alone or in combination in the diagnosis of GHI. A retrospective review of patients with GHI and idiopathic short stature (ISS) diagnosed in our centre and followed up to the completion of linear growth. Thirty-three GHI children and 56 children with ISS were evaluated. GHI diagnosis was based on fulfilment of anthropometric, endocrine and neuroradiological criteria: stature < or = -2 z-score, delayed bone age (at least 1 year), GH peak response to at least two different provocative tests < 10 micro g/l (20 mU/l), brain MRI positive for hypothalamus-pituitary abnormalities, catch-up growth during the first year of GH replacement therapy > or = 75th centile, peak GH response to a third provocative test after growth completion < 10 micro g/l (20 mU/l). Children with anthropometry resembling that of GHI but with peak GH responses > 10 micro g/l (20 mU/l) were diagnosed as ISS. All subjects underwent standard anthropometry. GH secretory status was assessed by clonidine, arginine and GHRH plus arginine stimulation tests. IGF-I and IGFBP-3 circulating levels were measured by immunoradiometric assay (IRMA). The following cut-off values were chosen to discriminate between GHI and nonGHI short children: HV < 25th centile over the 6-12 months prior to the initiation of GH therapy, peak GH responses < 10 or < 7 micro g/l (< 20 or < 14 mU/l) and IGF-I and IGFBP-3-values < -1.9 z-score. Sensitivity (true positive ratio) and specificity (true negative ratio) were evaluated. Taking 10 micro g/l (20 mU/l) as the cut-off value, sensitivity was 100% and specificity 57% for GH provocative tests, whereas taking 7 as the cut-off value, sensitivity was 66% and specificity rose to 78%. Sensitivity was 73% for IGF-I and 30% for IGFBP-3 measurement, whilst specificity was 95% for IGF-I and 98% for IGFBP-3 evaluation. HV assessment revealed a sensitivity of 82% and a specificity of 43%. When HV and IGF-I evaluations were used in combination, sensitivity reached 95% and specificity 96%. When both HV and IGF-I are normal (26% of our subjects) GHI may be ruled out, whereas when both the indices are subnormal (23%) GHI is so highly likely that the child may undergo only one GH provocative test and brain MRI and, thereafter, may begin GH therapy without any further test. In case of discrepancy, when IGF-I is normal and HV < 25th centile (44% of children), due to the relatively low sensitivity of IGF-I assessment and low specificity of HV, the patient should undergo GH tests and brain MRI. Finally, in the rare case of HV > 25th centile and subnormal IGF-I-values (7%), due to the high specificity of IGF-I measurement, the child should undergo one provocative test and brain MRI for the high suspicion of GHI. Our results suggest that a simple assessment of HV and basal IGF-I may exclude or, in association with only one stimulation test, confirm the diagnosis of GH insufficiency in more than half of patients with short stature.
Rotator cuff crepitus: could Codman really feel a cuff tear?
Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J
2014-07-01
The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.
Siddique, Juned; Ruhnke, Gregory W.; Flores, Andrea; Prochaska, Micah T.; Paesch, Elizabeth; Meltzer, David O.; Whelan, Chad T.
2015-01-01
Background Lower gastrointestinal bleeding (LGIB) is a common cause of acute hospitalization. Currently, there is no accepted standard for identifying patients with LGIB in hospital administrative data. The objective of this study was to develop and validate a set of classification algorithms that use hospital administrative data to identify LGIB. Methods Our sample consists of patients admitted between July 1, 2001 and June 30, 2003 (derivation cohort) and July 1, 2003 and June 30, 2005 (validation cohort) to the general medicine inpatient service of the University of Chicago Hospital, a large urban academic medical center. Confirmed cases of LGIB in both cohorts were determined by reviewing the charts of those patients who had at least 1 of 36 principal or secondary International Classification of Diseases, Ninth revision, Clinical Modification (ICD-9-CM) diagnosis codes associated with LGIB. Classification trees were used on the data of the derivation cohort to develop a set of decision rules for identifying patients with LGIB. These rules were then applied to the validation cohort to assess their performance. Results Three classification algorithms were identified and validated: a high specificity rule with 80.1% sensitivity and 95.8% specificity, a rule that balances sensitivity and specificity (87.8% sensitivity, 90.9% specificity), and a high sensitivity rule with 100% sensitivity and 91.0% specificity. Conclusion These classification algorithms can be used in future studies to evaluate resource utilization and assess outcomes associated with LGIB without the use of chart review. PMID:26406318
Comparison of four methods to assess colostral IgG concentration in dairy cows.
Chigerwe, Munashe; Tyler, Jeff W; Middleton, John R; Spain, James N; Dill, Jeffrey S; Steevens, Barry J
2008-09-01
To determine sensitivity and specificity of 4 methods to assess colostral IgG concentration in dairy cows and determine the optimal cutpoint for each method. Cross-sectional study. 160 Holstein dairy cows. 171 composite colostrum samples collected within 2 hours after parturition were used in the study. Test methods used to estimate colostral IgG concentration consisted of weight of the first milking, 2 hydrometers, and an electronic refractometer. Results of the test methods were compared with colostral IgG concentration determined by means of radial immunodiffusion. For each method, sensitivity and specificity for detecting colostral IgG concentration < 50 g/L were calculated across a range of potential cutpoints, and the optimal cutpoint for each test was selected to maximize sensitivity and specificity. At the optimal cutpoint for each method, sensitivity for weight of the first milking (0.42) was significantly lower than sensitivity for each of the other 3 methods (hydrometer 1, 0.75; hydrometer 2, 0.76; refractometer, 0.75), but no significant differences were identified among the other 3 methods with regard to sensitivity. Specificities at the optimal cutpoint were similar for all 4 methods. Results suggested that use of either hydrometer or the electronic refractometer was an acceptable method of screening colostrum for low IgG concentration; however, the manufacturer-defined scale for both hydrometers overestimated colostral IgG concentration. Use of weight of the first milking as a screening test to identify bovine colostrum with inadequate IgG concentration could not be justified because of the low sensitivity.
Vincent-Onabajo, Grace O; Owolabi, Mayowa O; Hamzat, Talhatu K
2014-01-01
To investigate the sensitivity and responsiveness of the Health-Related Quality of Life in Stroke Patients-40 (HRQOLISP-40) scale in evaluating stroke patients from onset to 12 months. Fifty-five patients with first-incidence stroke were followed-up for 12 months. The HRQOLISP-40 scale was used to assess health-related quality of life (HRQOL) while stroke severity was assessed with the Stroke Levity Scale. Sensitivity to change was assessed by analyzing changes in the HRQOLISP-40 scores between pairs of months with paired samples t-test. Standardized effect size (SES) and standardized response mean (SRM) were used to express responsiveness. Overall HRQOL and domains in the physical sphere of the HRQOLISP-40 were sensitive to change at different time intervals in the first 12 months post-stroke. Marked responsiveness (SES and SRM >0.7) was demonstrated by the overall scale, and the physical, psycho-emotional and cognitive domains at varying time intervals. For instance, SRM was greater than 0.7 between 1 and 6, 3 and 12, 1 and 9, and 1 and 12 months for both the physical and psycho-emotional domains. The HRQOLISP-40 is a sensitive and responsive stroke-specific quality of life measure that can be used to evaluate the outcome of stroke rehabilitation. Enhancing the health-related quality of life (HRQOL) of stroke survivors can be regarded as the ultimate goal of stroke rehabilitation. Sensitive and responsive stroke-specific HRQOL measures are required for use in evaluative studies, and clinical trials and practice. The Health-Related Quality of Life in Stroke Patients-40 (HRQOLISP-40) is a sensitive and responsive stroke-specific scale.
Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela
2015-05-15
Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.
Serra, Montserrat; Brazís, Pilar; Fondati, Alessandra; Puigdemont, Anna
2006-11-01
To assess binding of IgE to native, whole hydrolyzed, and separated hydrolyzed fractions of soy protein in serum obtained from dogs with experimentally induced soy protein hypersensitivity. 8 naïve Beagles (6 experimentally sensitized to native soy protein and 2 control dogs). 6 dogs were sensitized against soy protein by administration of allergens during a 90-day period. After the sensitization protocol was completed, serum concentrations of soy-specific IgE were measured and intradermal skin tests were performed in all 6 dogs to confirm that the dogs were sensitized against soy protein. Serum samples from each sensitized and control dog underwent western blot analysis to assess the molecular mass band pattern of the different allergenic soy fractions and evaluate reactivities to native and hydrolyzed soy protein. In sera from sensitized dogs, a characteristic band pattern with 2 major bands (approx 75 and 50 kd) and 2 minor bands (approx 31 and 20 kd) was detected, whereas only a diffuse band pattern associated with whole hydrolyzed soy protein was detected in the most reactive dog. Reactivity was evident only for the higher molecular mass peptide fraction. In control dogs, no IgE reaction to native or hydrolyzed soy protein was detected. Data suggest that the binding of soy-specific IgE to the hydrolyzed soy protein used in the study was significantly reduced, compared with binding of soy-specific IgE to the native soy protein, in dogs with experimentally induced soy hypersensitivity.
Estimating sensitivity and specificity for technology assessment based on observer studies.
Nishikawa, Robert M; Pesce, Lorenzo L
2013-07-01
The goal of this study was to determine the accuracy and precision of using scores from a receiver operating characteristic rating scale to estimate sensitivity and specificity. We used data collected in a previous study that measured the improvements in radiologists' ability to classify mammographic microcalcification clusters as benign or malignant with and without the use of a computer-aided diagnosis scheme. Sensitivity and specificity were estimated from the rating data from a question that directly asked the radiologists their biopsy recommendations, which was used as the "truth," because it is the actual recall decision, thus it is their subjective truth. By thresholding the rating data, sensitivity and specificity were estimated for different threshold values. Because of interreader and intrareader variability, estimated sensitivity and specificity values for individual readers could be as much as 100% in error when using rating data compared to using the biopsy recommendation data. When pooled together, the estimates using thresholding the rating data were in good agreement with sensitivity and specificity estimated from the recommendation data. However, the statistical power of the rating data estimates was lower. By simply asking the observer his or her explicit recommendation (eg, biopsy or no biopsy), sensitivity and specificity can be measured directly, giving a more accurate description of empirical variability and the power of the study can be maximized. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Carlsten, Chris; Dimich-Ward, Helen; Ferguson, Alexander; Becker, Allan; Dybuncio, Anne; Chan-Yeung, Moira
2011-02-01
The operating characteristics of PC(20) values used as cut-offs to define airway hyperresponsiveness, as it informs the diagnosis of asthma in children, are poorly understood. We examine data from a unique cohort to inform this concern. Determine the sensitivity and specificity of incremental PC(20) cut-offs for allergist-diagnosed asthma. Airway reactivity at age 7 was assessed in children within a birth cohort at high risk for asthma; PC(20) for methacholine was determined by standard technique including interpolation. The diagnosis of asthma was considered by the pediatric allergist without knowledge of the methacholine challenge results. Sensitivity and specificity were calculated using a cross-tabulation of asthma diagnosis with incremental PC(20) cut-off values, from 1.0 to 8.0 mg/ml, and plotted as receiver operator characteristic (ROC) curves. The "optimal" cut-off was defined as that PC(20) conferring maximal value for sensitivity plus specificity while the "balanced" cut-off was defined as that PC(20) at which sensitivity and specificity were most equal. 70/348 children (20.1%) were diagnosed with asthma. The optimal and balanced PC(20) cut-offs, both for all children and for females alone, were respectively 3 mg/ml (sensitivity 80.0%, specificity 49.1%) and 2 mg/ml (sensitivity 63.1%, specificity 64.7%). For males alone, the "optimal" and "balanced" PC(20) cut-offs were both 2 mg/ml. For this cohort of 7-year olds at high risk for asthma, methacholine challenge testing using a cut-off value of PC(20) 3 mg/ml conferred the maximal sum of specificity plus sensitivity. For contexts in which higher sensitivity or specificity is desired, other cut-offs may be preferred. Copyright © 2011 Wiley-Liss, Inc.
Leddy, Abigail L; Crowner, Beth E; Earhart, Gammon M
2011-01-01
Gait impairments, balance impairments, and falls are prevalent in individuals with Parkinson disease (PD). Although the Berg Balance Scale (BBS) can be considered the reference standard for the determination of fall risk, it has a noted ceiling effect. Development of ceiling-free measures that can assess balance and are good at discriminating "fallers" from "nonfallers" is needed. The purpose of this study was to compare the Functional Gait Assessment (FGA) and the Balance Evaluation Systems Test (BESTest) with the BBS among individuals with PD and evaluate the tests' reliability, validity, and discriminatory sensitivity and specificity for fallers versus nonfallers. This was an observational study of community-dwelling individuals with idiopathic PD. The BBS, FGA, and BESTest were administered to 80 individuals with PD. Interrater reliability (n=15) was assessed by 3 raters. Test-retest reliability was based on 2 tests of participants (n=24), 2 weeks apart. Intraclass correlation coefficients (2,1) were used to calculate reliability, and Spearman correlation coefficients were used to assess validity. Cutoff points, sensitivity, and specificity were based on receiver operating characteristic plots. Test-retest reliability was .80 for the BBS, .91 for the FGA, and .88 for the BESTest. Interrater reliability was greater than .93 for all 3 tests. The FGA and BESTest were correlated with the BBS (r=.78 and r=.87, respectively). Cutoff scores to identify fallers were 47/56 for the BBS, 15/30 for the FGA, and 69% for the BESTest. The overall accuracy (area under the curve) for the BBS, FGA, and BESTest was .79, .80, and .85, respectively. Fall reports were retrospective. Both the FGA and the BESTest have reliability and validity for assessing balance in individuals with PD. The BESTest is most sensitive for identifying fallers.
Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Granata, Vincenza; Delrio, Paolo; Bianco, Francesco; Pecori, Biagio; Botti, Gerardo; Tatangelo, Fabiana; Caracò, Corradina; Aloj, Luigi; Avallone, Antonio; Lastoria, Secondo
2017-01-01
Purpose To investigate dynamic contrast enhanced-MRI (DCE-MRI) in the preoperative chemo-radiotherapy (CRT) assessment for locally advanced rectal cancer (LARC) compared to18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). Methods 75 consecutive patients with LARC were enrolled in a prospective study. DCE-MRI analysis was performed measuring SIS: linear combination of percentage change (Δ) of maximum signal difference (MSD) and wash-out slope (WOS). 18F-FDG PET/CT analysis was performed using SUV maximum (SUVmax). Tumor regression grade (TRG) were estimated after surgery. Non-parametric tests, receiver operating characteristic were evaluated. Results 55 patients (TRG1-2) were classified as responders while 20 subjects as non responders. ΔSIS reached sensitivity of 93%, specificity of 80% and accuracy of 89% (cut-off 6%) to differentiate responders by non responders, sensitivity of 93%, specificity of 69% and accuracy of 79% (cut-off 30%) to identify pathological complete response (pCR). Therapy assessment via ΔSUVmax reached sensitivity of 67%, specificity of 75% and accuracy of 70% (cut-off 60%) to differentiate responders by non responders and sensitivity of 80%, specificity of 31% and accuracy of 51% (cut-off 44%) to identify pCR. Conclusions CRT response assessment by DCE-MRI analysis shows a higher predictive ability than 18F-FDG PET/CT in LARC patients allowing to better discriminate significant and pCR. PMID:28042958
Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Granata, Vincenza; Delrio, Paolo; Bianco, Francesco; Pecori, Biagio; Botti, Gerardo; Tatangelo, Fabiana; Caracò, Corradina; Aloj, Luigi; Avallone, Antonio; Lastoria, Secondo
2017-01-31
To investigate dynamic contrast enhanced-MRI (DCE-MRI) in the preoperative chemo-radiotherapy (CRT) assessment for locally advanced rectal cancer (LARC) compared to18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). 75 consecutive patients with LARC were enrolled in a prospective study. DCE-MRI analysis was performed measuring SIS: linear combination of percentage change (Δ) of maximum signal difference (MSD) and wash-out slope (WOS). 18F-FDG PET/CT analysis was performed using SUV maximum (SUVmax). Tumor regression grade (TRG) were estimated after surgery. Non-parametric tests, receiver operating characteristic were evaluated. 55 patients (TRG1-2) were classified as responders while 20 subjects as non responders. ΔSIS reached sensitivity of 93%, specificity of 80% and accuracy of 89% (cut-off 6%) to differentiate responders by non responders, sensitivity of 93%, specificity of 69% and accuracy of 79% (cut-off 30%) to identify pathological complete response (pCR). Therapy assessment via ΔSUVmax reached sensitivity of 67%, specificity of 75% and accuracy of 70% (cut-off 60%) to differentiate responders by non responders and sensitivity of 80%, specificity of 31% and accuracy of 51% (cut-off 44%) to identify pCR. CRT response assessment by DCE-MRI analysis shows a higher predictive ability than 18F-FDG PET/CT in LARC patients allowing to better discriminate significant and pCR.
Addressing uncertainty in vulnerability assessments [Chapter 5
Linda Joyce; Molly Cross; Evan Girvatz
2011-01-01
This chapter addresses issues and approaches for dealing with uncertainty specifically within the context of conducting climate change vulnerability assessments (i.e., uncertainties related to identifying and modeling the sensitivities, levels of exposure, and adaptive capacity of the assessment targets).
Rajeev, Aysha; Tuinebreijer, Wim; Mohamed, Abdalla; Newby, Mike
2018-01-01
The assessment of a patient with chronic hip pain can be challenging. The differential diagnosis of intra-articular pathology causing hip pain can be diverse. These includes conditions such as osteoarthritis, fracture, and avascular necrosis, synovitis, loose bodies, labral tears, articular pathology and, femoro-acetabular impingement. Magnetic resonance imaging (MRI) arthrography of the hip has been widely used now for diagnosis of articular pathology of the hip. A retrospective analysis of 113 patients who had MRI arthrogram and who underwent hip arthroscopy was included in the study. The MRI arthrogram was performed using gadolinium injection and reported by a single radiologist. The findings were then compared to that found on arthroscopy. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy and 95% confidence interval were calculated for each pathology. Labral tear-sensitivity 84% (74.3-90.5), specificity 64% (40.7-82.8), PPV 91% (82.1-95.8), NPV 48% (29.5-67.5), accuracy 80%. Delamination -sensitivity 7% (0.8-22.1), specificity 98% (91.6-99.7), PPV 50% (6.8-93.2), NPV 74% (65.1-82.2) and accuracy 39%. Chondral changes-sensitivity 25% (13.3-38.9), specificity 83% (71.3-91.1), PPV 52% (30.6-73.2), NPV 59% (48.0-69.2) and accuracy 58%. Femoro-acetabular impingement (CAM deformity)-sensitivity 34% (19.6-51.4), specificity 83% (72.2-90.4), PPV 50% (29.9-70.1), NPV 71% (60.6-80.5) and accuracy 66%. Synovitis-sensitivity 11% (2.3-28.2), specificity 99% (93.6-100), PPV 75% (19.4-99.4), NPV 77% (68.1-84.6) and accuracy 77%. Our study conclusions are MRI arthrogram is a useful investigation tool in detecting labral tears, it is also helpful in the diagnosis of femoro-acetabular impingement. However, when it comes to the diagnosis of chondral changes, defects and cartilage delamination, the sensitivity and accuracy are low.
Gray, Dona L.; O’Brien, Kevin D.; D’Alessio, David A.; Brehm, Bonnie J.; Deeg, Mark A.
2013-01-01
Context Although circulating glycosylphosphatidylinositol-specific phospholipase D, a minor high density lipoprotein-associated protein, is elevated in patients with insulin resistance or high triglycerides, no information is available on the effect of weight loss or changes in insulin sensitivity on circulating glycosylphosphatidylinositol-specific phospholipase D levels. Objective Determine the effect of weight loss and changes in insulin sensitivity on plasma glycosylphosphatidylinositol-specific phospholipase D levels. Participants Forty two non-diabetic obese women. Intervention Three month dietary intervention randomizing patients to a low fat or a low carbohydrate diet. Main outcome measures Plasma glycosylphosphatidylinositol-specific phospholipase D levels and insulin sensitivity as estimated by the homeostasis model assessment. Results The very low carbohydrate diet group lost more weight after 3 months (−7.6 ± 3.2 vs. −4.2 ± 3.5 kg, P < 0.01) although the decrease in insulin resistance was similar between groups. Weight loss with either diet did not alter plasma glycosylphosphatidylinositol-specific phospholipase D levels. However, baseline glycosylphosphatidylinositol-specific phospholipase D levels correlated with the change in insulin sensitivity in response to the low fat diet while baseline insulin sensitivity correlated the change in insulin sensitivity in response to the low carbohydrate diet. Conclusions Plasma GPI-PLD may serve as a clinical tool to determine the effect of a low fat diet on insulin sensitivity. PMID:18328347
Quantitative assessment of serum-specific IgE in the diagnosis of human cystic echinococcosis.
Marinova, I; Nikolov, G; Michova, A; Kurdova, R; Petrunov, B
2011-07-01
Anti-Echinococcus serum immunoglobulin (Ig)E was assessed by the ImmunoCAP system and compared with anti-Echinococcus serum IgG assessed by enzyme-linked immunosorbent assay (ELISA) and Western blot. The ImmunoCAP system revealed very high specificity (one false positive of 110 healthy individuals), low cross-reactivity (one false positive of 58 patients with other diseases) and decreased sensitivity (73.55%). Receiver operating characteristic analysis displayed a beneficial diagnostic value with high accuracy. Comparison of the ImmunoCAP system with ELISA and Western blot showed significantly higher specificity and significantly lower cross-reactivity compared with the ELISA. Examination of sera from 155 patients with cystic echinococcosis (CE) showed varying levels of anti-Echinococcus IgE (range, 0.01-118.33 kUA/L). However, most samples had moderately elevated IgE levels. Analysis of serum-specific IgE revealed significantly higher sensitivity of the ImmunoCAP system and significantly higher antibody levels in hepatic CE compared with pulmonary CE. © 2011 Blackwell Publishing Ltd.
Gismervik, Sigmund Ø; Drogset, Jon O; Granviken, Fredrik; Rø, Magne; Leivseth, Gunnar
2017-01-25
Physical examination tests of the shoulder (PETS) are clinical examination maneuvers designed to aid the assessment of shoulder complaints. Despite more than 180 PETS described in the literature, evidence of their validity and usefulness in diagnosing the shoulder is questioned. This meta-analysis aims to use diagnostic odds ratio (DOR) to evaluate how much PETS shift overall probability and to rank the test performance of single PETS in order to aid the clinician's choice of which tests to use. This study adheres to the principles outlined in the Cochrane guidelines and the PRISMA statement. A fixed effect model was used to assess the overall diagnostic validity of PETS by pooling DOR for different PETS with similar biomechanical rationale when possible. Single PETS were assessed and ranked by DOR. Clinical performance was assessed by sensitivity, specificity, accuracy and likelihood ratio. Six thousand nine-hundred abstracts and 202 full-text articles were assessed for eligibility; 20 articles were eligible and data from 11 articles could be included in the meta-analysis. All PETS for SLAP (superior labral anterior posterior) lesions pooled gave a DOR of 1.38 [1.13, 1.69]. The Supraspinatus test for any full thickness rotator cuff tear obtained the highest DOR of 9.24 (sensitivity was 0.74, specificity 0.77). Compression-Rotation test obtained the highest DOR (6.36) among single PETS for SLAP lesions (sensitivity 0.43, specificity 0.89) and Hawkins test obtained the highest DOR (2.86) for impingement syndrome (sensitivity 0.58, specificity 0.67). No single PETS showed superior clinical test performance. The clinical performance of single PETS is limited. However, when the different PETS for SLAP lesions were pooled, we found a statistical significant change in post-test probability indicating an overall statistical validity. We suggest that clinicians choose their PETS among those with the highest pooled DOR and to assess validity to their own specific clinical settings, review the inclusion criteria of the included primary studies. We further propose that future studies on the validity of PETS use randomized research designs rather than the accuracy design relying less on well-established gold standard reference tests and efficient treatment options.
Marin, Marcelo T.; Berkow, Alexander; Golden, Sam A.; Koya, Eisuke; Planeta, Cleopatra S.; Hope, Bruce T.
2009-01-01
Learned associations are hypothesized to develop between drug effects and contextual stimuli during repeated drug administration to produce context-specific sensitization that is expressed only in the drug-associated environment and not in a non-drug paired environment. Neuroadaptations that mediate such context-specific behavior are largely unknown. We investigated context-specific modulation of CREB phosphorylation and four upstream kinases in nucleus accumbens that phosphorylate CREB, including ERK, PKA, CaMKII and IV. Rats received seven once daily injections of cocaine or saline in one of two distinct environments outside their home cages. Seven days later, test injections of cocaine or saline were administered in either the Paired or the Non-paired environment. CREB and ERK phosphorylation were assessed with immunohistochemistry while phosphorylation of the remaining kinases, as well as CREB and ERK, were assessed by Western blotting. Repeated cocaine administration produced context-specific sensitized locomotor responses accompanied by context-specific enhancement of the number of cocaine-induced phosphoCREB and phosphoERK immunoreactive nuclei in a minority of neurons. In contrast, CREB and CaMKIV phosphorylation in nucleus accumbens homogenates were decreased by cocaine test injections. We have recently shown that a small number of cocaine-activated accumbens neurons mediate the learned association between cocaine effects and the drug administration environment to produce context-specific sensitization. The corresponding cocaine and context-specific phosphorylation of ERK and CREB in cocaine-activated accumbens neurons in the present study suggests that this signal transduction pathway is also selectively activated in the same set of accumbens neurons. PMID:19912338
Sensitivity to Spatiotemporal Percepts Predicts the Perception of Emotion
Castro, Vanessa L.; Boone, R. Thomas
2015-01-01
The present studies examined how sensitivity to spatiotemporal percepts such as rhythm, angularity, configuration, and force predicts accuracy in perceiving emotion. In Study 1, participants (N = 99) completed a nonverbal test battery consisting of three nonverbal emotion perception tests and two perceptual sensitivity tasks assessing rhythm sensitivity and angularity sensitivity. Study 2 (N = 101) extended the findings of Study 1 with the addition of a fourth nonverbal test, a third configural sensitivity task, and a fourth force sensitivity task. Regression analyses across both studies revealed partial support for the association between perceptual sensitivity to spatiotemporal percepts and greater emotion perception accuracy. Results indicate that accuracy in perceiving emotions may be predicted by sensitivity to specific percepts embedded within channel- and emotion-specific displays. The significance of such research lies in the understanding of how individuals acquire emotion perception skill and the processes by which distinct features of percepts are related to the perception of emotion. PMID:26339111
Carrillo, Sergio A; Daniel, Vincent C; Hall, Nathan; Hitchcock, Charles L; Ross, Patrick; Kassis, Edmund S
2012-05-01
The 5-year survival for patients with resected stage II (N1) non-small cell lung cancer ranges from 40% to 55%. No data exist addressing the benefit of neoadjuvant therapy for patients with stage II disease. This is largely in part due to the lack of a reliable, minimally invasive method to assess hilar nodes. This study is aimed at determining the ability of fusion positron emission/computed tomography (PET/CT) to identify hilar metastases in patients with resected non-small cell lung cancer. A retrospective review of surgically resected patients with fusion PET/CT within 30 days of resection was performed. The sensitivity, specificity, positive predictive value, and negative predictive value for PET/CT in detecting hilar nodal metastases was calculated for a range of maximum standardized uptake values (SUVmax). Hilar nodes from patients with falsely positive PET/CT scans were analyzed for the presence of histoplasmosis. Additionally, the impact of hilar node size greater than 1 centimeter on the calculated values was assessed. There were 119 patients evaluated. The number of lymph nodes resected ranged from 1 to 12 (X=2.98). There was decreased sensitivity and increased specificity with higher SUVmax cutoff values. At the standard SUVmax value of 2.5, the sensitivity and specificity were only 48.5% and 80.2%. The addition of size of hilar node by CT led to a modest improvement in sensitivity at all SUVmax cutoff values. Fusion PET/CT lacks sensitivity and specificity in identifying hilar nodal metastasis in patients with resected non-small cell lung cancer. Further prospective studies assessing the utility of PET/CT versus alternative sampling techniques are warranted. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
[Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].
Acevedo González, Juan C; Quintero Oliveros, Silvia
2015-01-01
Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
Jewett, A; Smith, B D; Garfein, R S; Cuevas-Mota, J; Teshale, E H; Weinbaum, C M
2012-07-01
Approximately 4.1 million Americans are estimated to have been infected with hepatitis C virus (HCV), 45-85% of whom are unaware of their infection. Persons who inject drugs (PWID) account for 55.8% of all persons with HCV antibody (anti-HCV) in the U.S. PWID have limited access to healthcare and are infrequently tested for anti-HCV using conventional laboratory assays. To evaluate performance characteristics (sensitivity and specificity) of three, pre-market rapid point-of-care tests (one oral fluid and two finger-stick assays) from two manufacturers (Chembio and MedMira) in settings providing services to young adult PWID in San Diego, CA. Behavioral risk assessment surveys and testing for HCV were conducted among persons who reported injection drug use (IDU) within the past 6 months as part of the Study to Assess Hepatitis C Risk (STAHR) among PWID aged 18-40 years in 2009-2010. Sensitivity and specificity of the rapid anti-HCV assays were evaluated among STAHR participants, using two commonly used testing algorithms. Variability in sensitivity (76.6-97.1%) and specificity (99.0-100.0%) was found across assays. The highest sensitivity achieved for the Chembio finger-stick blood, Chembio oral fluid and MedMira finger-stick blood tests was 97.1%, 85.4% and 80.0% respectively; the highest specificity was 99.0%, 100.0% and 100.0%, respectively. In multivariate analysis false negative anti-HCV results were associated with female sex for the MedMira blood assay. Sensitive anti-HCV rapid assays are appropriate and feasible for high-prevalence, high-risk populations such as young PWID. Copyright © 2012 Elsevier B.V. All rights reserved.
Kumar, Subodh; Bansal, Virinder Kumar; Muduly, Dillip Kumar; Sharma, Pawan; Misra, Mahesh C; Chumber, Sunil; Singh, Saraman; Bhardwaj, D N
2015-12-01
Focused assessment with sonography for trauma (FAST) is a limited ultrasound examination, primarily aimed at the identification of the presence of free intraperitoneal or pericardial fluid. In the context of blunt trauma abdomen (BTA), free fluid is usually due to hemorrhage, bowel contents, or both; contributes towards the timely diagnosis of potentially life-threatening hemorrhage; and is a decision-making tool to help determine the need for further evaluation or operative intervention. Fifty patients with blunt trauma abdomen were evaluated prospectively with FAST. The findings of FAST were compared with contrast-enhanced computed tomography (CECT), laparotomy, and autopsy. Any free fluid in the abdomen was presumed to be hemoperitoneum. Sonographic findings of intra-abdominal free fluid were confirmed by CECT, laparotomy, or autopsy wherever indicated. In comparing with CECT scan, FAST had a sensitivity, specificity, and accuracy of 77.27, 100, and 79.16 %, respectively, in the detection of free fluid. When compared with surgical findings, it had a sensitivity, specificity, and accuracy of 94.44, 50, and 90 %, respectively. The sensitivity of FAST was 75 % in determining free fluid in patients who died when compared with autopsy findings. Overall sensitivity, specificity, and accuracy of FAST were 80.43, 75 and 80 %, respectively, for the detection of free fluid in the abdomen. From this study, we can safely conclude that FAST is a rapid, reliable, and feasible investigation in patients with BTA, and it can be performed easily, safely, and quickly in the emergency room with a reasonable sensitivity, specificity, and accuracy. It helps in the initial triage of patients for assessing the need for urgent surgery.
Keo, Hong H; Schilling, Marianne; Büchel, Roland; Gröchenig, Ernst; Engelberger, Rolf P; Willenberg, Torsten; Baumgartner, Iris; Gretener, Silvia B
2013-06-01
Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.
Biesaga, Beata; Szostek, Sława; Klimek, Małgorzata; Jakubowicz, Jerzy; Wysocka, Joanna
2012-07-04
The aim of this study was to analyze the correlation between real-time PCR (RT-PCR) treated as a reference method and in situ hybridization with tyramide amplification system (ISH-TSA) in the detection of HPV16 and 18 infection and the assessment of viral genome status. The study was performed on cervical cancer biopsies fixed in 10% neutral buffered formalin and embedded in paraffin obtained from 85 women. TaqMan-based 5'exonuclease RT-PCR with type-specific primers was used to assess HPV16 and 18 infections and genome status. Viral infection and genome status was also assessed by ISH-TSA. RT-PCR revealed 76 (89.4%), and ISH-TSA 81 (95.3%) cancers with HPV16 and 18 infections. The ISH-TSA sensitivity and specificity were: 96.1% and 11.1% compared to RT-PCR. The difference between these techniques in HPV detection was significant (p = 0.000). Among 76 HPV16/18 positive cancers in RT-PCR, there were 30 (39.5%) with integrated and 46 (60.5%) with mixed viral genome form. According to ISH-TSA, there were 39 (51.3%) samples with integrated and 37 with mixed form (48.7%). The sensitivity and specificity of ISH-TSA in genome status assessment were 70.0% and 60.9%, respectively. The difference between RT-PCR and ISH-TSA in genome state detection was not statistically significant (p = 0.391). These results suggest that ISH-TSA shows insufficient specificity in HPV detection for use in clinical practice. However, this assay could be applied for viral genome status assessment.
Malhotra, Chetna; Chan, Angelique; Matchar, David; Seow, Dennis; Chuo, Adeline; Do, Young Kyung
2013-07-01
The Short Portable Mental Status Questionnaire (SPMSQ) is a brief cognitive screening instrument, which is easy to use by a healthcare worker with little training. However, the validity of this instrument has not been established in Singapore. Thus, the primary aim of this study was to determine the diagnostic performance of SPMSQ for screening dementia among patients attending outpatient cognitive assessment clinics and to assess whether the appropriate cut-off score varies by patient's age and education. A secondary aim of the study was to map the SPMSQ scores with Mini-Mental State Examination (MMSE) scores. SPMSQ and MMSE were administered by a trained interviewer to 127 patients visiting outpatient cognitive assessment clinics at the Singapore General Hospital, Changi General Hospital and Tan Tock Seng Hospital. The geriatricians at these clinics then diagnosed these patients with dementia or no dementia (reference standard). Sensitivity and specificity of SPMSQ with different cut-off points (number of errors) were calculated and compared to the reference standard using the Receiver Operator Characteristic (ROC) analysis. Correlation coefficient was also calculated between MMSE and SPMSQ scores. Based on the ROC analysis and a balance of sensitivity and specificity, the appropriate cut-off for SPMSQ was found to be 5 or more errors (sensitivity 78%, specificity 75%). The cut-off varied by education, but not by patient's age. There was a high correlation between SPMSQ and MMSE scores (r = 0.814, P <0.0001). Despite the advantage of being a brief screening instrument for dementia, the use of SPMSQ is limited by its low sensitivity and specificity, especially among patients with less than 6 years of education.
Hädener, Marianne; Martin Fabritius, Marie; König, Stefan; Giroud, Christian; Weinmann, Wolfgang
2017-07-01
Heavy cannabis consumption is considered incompatible with safe driving. In Swiss traffic policy, drivers suspected of regular cannabis use are therefore required to undergo medical assessment of their long-term fitness to drive. A whole blood concentration of the cannabis metabolite 11-nor-9-carboxy-Δ 9 -tetrahydrocannabinol (THCCOOH) of 40 µg/L is currently used by Swiss forensic experts as the decision limit for regular cannabis consumption. The present study aimed to investigate the suitability of THCCOOH-glucuronide blood levels as an additional and/or better marker for the frequency of cannabis use. Whole blood samples collected from 23 heavy (≥10 joints/month) and 25 occasional smokers (≥1 joint/month, but ≤ 1 joint/week) enrolled in a placebo-controlled cannabis smoking study were analyzed for THCCOOH and THCCOOH-glucuronide. Based on receiver operating characteristic (ROC) curve analysis, concentration thresholds could be established for distinguishing between these two groups. Proposed thresholds for heavy use were THCCOOH-glucuronide > 52 µg/L (100% specificity; 41% sensitivity) and/or total THCCOOH > 58 µg/L (100% specificity; 43% sensitivity). Optimum thresholds for occasional use were THCCOOH-glucuronide < 5 µg/L (73% specificity; 97% sensitivity) and/or total THCCOOH < 5 µg/L (62% specificity; 98% sensitivity). Our results indicate that the THCCOOH-glucuronide whole blood concentration is a useful parameter that complements the free THCCOOH level to assess the frequency of cannabis consumption. The consideration of the blood concentrations of both free and glucuronidated THCCOOH improves the identification of heavy users whose fitness to drive has to be carefully assessed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Development and Validation of Osteoporosis Risk-Assessment Model for Korean Men
Oh, Sun Min; Song, Bo Mi; Nam, Byung-Ho; Rhee, Yumie; Moon, Seong-Hwan; Kim, Deog Young; Kang, Dae Ryong
2016-01-01
Purpose The aim of the present study was to develop an osteoporosis risk-assessment model to identify high-risk individuals among Korean men. Materials and Methods The study used data from 1340 and 1110 men ≥50 years who participated in the 2009 and 2010 Korean National Health and Nutrition Examination Survey, respectively, for development and validation of an osteoporosis risk-assessment model. Osteoporosis was defined as T score ≤-2.5 at either the femoral neck or lumbar spine. Performance of the candidate models and the Osteoporosis Self-assessment Tool for Asian (OSTA) was compared with sensitivity, specificity, and area under the receiver operating characteristics curve (AUC). A net reclassification improvement was further calculated to compare the developed Korean Osteoporosis Risk-Assessment Model for Men (KORAM-M) with OSTA. Results In the development dataset, the prevalence of osteoporosis was 8.1%. KORAM-M, consisting of age and body weight, had a sensitivity of 90.8%, a specificity of 42.4%, and an AUC of 0.666 with a cut-off score of -9. In the validation dataset, similar results were shown: sensitivity 87.9%, specificity 39.7%, and AUC 0.638. Additionally, risk categorization with KORAM-M showed improved reclassification over that of OSTA up to 22.8%. Conclusion KORAM-M can be simply used as a pre-screening tool to identify candidates for dual energy X-ray absorptiometry tests. PMID:26632400
Tseng, Dorine S J; van Santvoort, Hjalmar C; Fegrachi, Samira; Besselink, Marc G; Zuithoff, Nicolaas P A; Borel Rinkes, Inne H; van Leeuwen, Maarten S; Molenaar, I Quintus
2014-12-01
Computed tomography (CT) is the most widely used method to assess resectability of pancreatic and peri-ampullary cancer. One of the contra-indications for curative resection is the presence of extra-regional lymph node metastases. This meta-analysis investigates the accuracy of CT in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. We systematically reviewed the literature according to the PRISMA guidelines. Studies reporting on CT assessment of extra-regional lymph nodes in patients undergoing pancreatoduodenectomy were included. Data on baseline characteristics, CT-investigations and histopathological outcomes were extracted. Diagnostic accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity were calculated for individual studies and pooled data. After screening, 4 cohort studies reporting on CT-findings and histopathological outcome in 157 patients with pancreatic or peri-ampullary cancer were included. Overall, diagnostic accuracy, specificity and NPV varied from 63 to 81, 80-100% and 67-90% respectively. However, PPV and sensitivity ranged from 0 to 100% and 0-38%. Pooled sensitivity, specificity, PPV and NPV were 25%, 86%, 28% and 84% respectively. CT has a low diagnostic accuracy in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. Therefore, suspicion of extra-regional lymph node metastases on CT alone should not be considered a contra-indication for exploration. Copyright © 2014 Elsevier Ltd. All rights reserved.
[Psychometric properties and diagnostic value of 'lexical screening for aphasias'].
Pena-Chavez, R; Martinez-Jimenez, L; Lopez-Espinoza, M
2014-09-16
INTRODUCTION. Language assessment in persons with brain injury makes it possible to know whether they require language rehabilitation or not. Given the importance of a precise evaluation, assessment instruments must be valid and reliable, so as to avoid mistaken and subjective diagnoses. AIM. To validate 'lexical screening for aphasias' in a sample of 58 Chilean individuals. SUBJECTS AND METHODS. A screening-type language test, lasting 20 minutes and based on the lexical processing model devised by Patterson and Shewell (1987), was constructed. The sample was made up of two groups containing 29 aphasic subjects and 29 control subjects from different health centres in the regions of Biobio and Maule, Chile. Their ages ranged between 24 and 79 years and had between 0 and 17 years' schooling. Tests were carried out to determine discriminating validity, concurrent validity with the aphasia disorder assessment battery, reliability, sensitivity and specificity. RESULTS. The statistical analysis showed a high discriminating validity (p < 0.001), an acceptable mean concurrent validity with aphasia disorder assessment battery (rs = 0.65), high mean reliability (alpha = 0.87), moderate mean sensitivity (69%) and high mean specificity (86%). CONCLUSION. 'Lexical screening for aphasias' is valid and reliable for assessing language in persons with aphasias; it is sensitive for detecting aphasic subjects and is specific for precluding language disorders in persons with normal language abilities.
ASSESSMENT OF THE REPRODUCTIVE AXIS: COMPARING CRITICAL PERIODS OF HORMONE SENSITIVITY.
Japanese medaka (Oryzias latipes) have been developed as a model species to compare the effects of endocrine active chemicals at critical life-stage periods of hormonal sensitivity, specifically as reproductively active adults, during the developmental period of differentiation, ...
Pearson, Matthew R; Bravo, Adrian J; Kirouac, Megan; Witkiewitz, Katie
2017-02-01
To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n=1726) and COMBINE (n=1383). In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pearson, Matthew R.; Bravo, Adrian J.; Kirouac, Megan; Witkiewitz, Katie
2017-01-01
Background To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. Methods We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n = 1,726) and COMBINE (n = 1,383). Results In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. Conclusions These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. PMID:28038361
Structural and functional assessment of macula to diagnose glaucoma.
Rao, H L; Hussain, R S M; Januwada, M; Pillutla, L N; Begum, V U; Chaitanya, A; Senthil, S; Garudadri, C S
2017-04-01
PurposeTo compare the diagnostic abilities of structural (ganglion cell-inner plexiform layer (GCIPL) thickness measured using spectral domain optical coherence tomography (SDOCT)) and functional (visual sensitivities measured using standard automated perimetry (SAP) and microperimetry (MP)) assessments of macula in glaucoma.MethodsIn a prospective study, 46 control eyes (28 subjects) and 61 glaucoma eyes (46 patients) underwent visual sensitivity estimation at macula (central 10°) by SAP and MP, and GCIPL thickness measurement at macula by SDOCT. Glaucoma was diagnosed by experts based on the optic disc and retinal nerve fiber layer changes. Area under the receiver-operating characteristic (AUC) curves and sensitivities at 95% specificity were used to assess the diagnostic ability of visual sensitivity and GCIPL measurements at various macular sectors.ResultsAUCs of GCIPL parameters ranged between 0.58 and 0.79. AUCs of SAP and MP sensitivities ranged between 0.59 and 0.71, and 0.59 and 0.72, respectively. There were no statistically significant differences between the AUCs of corresponding sector measurements (P>0.10 for all comparisons). Sensitivities at 95% specificities ranged from 31-59% for GCIPL parameters, 16-34% for SAP, and 8-38% for MP parameters. Sensitivities were significantly better with GCIPL compared with SAP and MP parameters in diagnosing glaucoma. Inferotemporal, inferior, and superotemporal sector measurements of GCIPL and visual sensitivity showed the best abilities to diagnose glaucoma.ConclusionsComparing the diagnostic abilities of structural and functional tests at macula in glaucoma, GCIPL thickness measurements with SDOCT performed better than the visual sensitivity measurements by SAP and MP.
Motamed, Nima; Miresmail, Seyed Javad Haji; Rabiee, Behnam; Keyvani, Hossein; Farahani, Behzad; Maadi, Mansooreh; Zamani, Farhad
2016-03-01
The present study was carried out to determine the optimal cutoff points for homeostatic model assessment (HOMA-IR) and quantitative insulin sensitivity check index (QUICKI) in the diagnosis of metabolic syndrome (MetS) and non-alcoholic fatty liver disease (NAFLD). The baseline data of 5511 subjects aged ≥18years of a cohort study in northern Iran were utilized to analyze. Receiver operating characteristic (ROC) analysis was conducted to determine the discriminatory capability of HOMA-IR and QUICKI in the diagnosis of MetS and NAFLD. Youden index was utilized to determine the optimal cutoff points of HOMA-IR and QUICKI in the diagnosis of MetS and NAFLD. The optimal cutoff points for HOMA-IR in the diagnosis of MetS and NAFLD were 2.0 [sensitivity=64.4%, specificity=66.8%] and 1.79 [sensitivity=66.2%, specificity=62.2%] in men and were 2.5 [sensitivity=57.6%, specificity=67.9%] and 1.95 [sensitivity=65.1%, specificity=54.7%] in women respectively. Furthermore, the optimal cutoff points for QUICKI in the diagnosis of MetS and NAFLD were 0.343 [sensitivity=63.7%, specificity=67.8%] and 0.347 [sensitivity=62.9%, specificity=65.0%] in men and were 0.331 [sensitivity=55.7%, specificity=70.7%] and 0.333 [sensitivity=53.2%, specificity=67.7%] in women respectively. Not only the optimal cutoff points of HOMA-IR and QUICKI were different for MetS and NAFLD, but also different cutoff points were obtained for men and women for each of these two conditions. Copyright © 2016 Elsevier Inc. All rights reserved.
Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa
2017-01-17
Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.
Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit
2015-03-01
Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.
De la Torre, Gabriel G; Perez, Maria J; Ramallo, Miguel A; Randolph, Christopher; González-Villegas, Macarena Bernal
2016-04-01
In recent years, a number of studies focusing on the evaluation of neuropsychological deficits in individuals with schizophrenia have shown deficits that include several cognitive functions. Attention deficits as well as memory or executive function deficits are common in this kind of disorder together with sustained attention problems, working memory deficiencies, and problem-solving difficulties, among many others. Currently, the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) is gaining special importance in the evaluation of the cognitive deficits associated with schizophrenia. In this article, we describe an RBANS screening in a sample of 88 Spanish patients diagnosed with schizophrenia. We also aimed to check the battery's reliability, sensitivity, and specificity in the studied sample. We performed a comparative study with 88 healthy participants. The results showed a reliability index value of α = .795 and an item value of α = .762. For total test reliability, we obtained an index value of α = .761 and an item value of α = .762. Sensitivity score was 87.5% and specificity 86.4%. RBANS obtained good reliability, sensitivity, and specificity scores and represents a good screening tool in detecting cognitive deficits associated with schizophrenia. © The Author(s) 2015.
Sensitivity and specificity of the online version of ImPACT in high school and collegiate athletes.
Schatz, Philip; Sandel, Natalie
2013-02-01
The utility of postconcussion neurocognitive testing versus symptom data has been debated. The sensitivity of the desktop version of the Immediate Post-concussion assessment and cognitive testing (ImPACT) tool has been documented, but psychometric properties of the recently released online version of ImPACT have yet to be fully established. To document the sensitivity of the online ImPACT version in samples of (1) symptomatic concussed (high school and collegiate) athletes, and (2) asymptomatic concussed (high school and collegiate) athletes suspected of hiding their concussions. Cohort study; level of evidence, 3. A total of 81 athletes observed to sustain a concussion by a certified athletic trainer or team physician, a finding that was confirmed with reported postconcussion symptoms, completed the ImPACT test within 3 days of injury. Data were compared with an independent sample of 81 athletes who completed preseason baseline cognitive assessments using ImPACT and who were matched (with concussed athletes) on the basis of sex, age, sport, concussion history, and absence of attention deficit hyperactivity disorder and learning disability. An independent group of 37 athletes who were also observed to sustain a concussion completed ImPACT within 3 days of injury. These athletes reported no postconcussion symptoms but were noted for suspected invalid response patterns on ImPACT (impulse control index >30 and verbal memory index <69%). The subscale data from the assessments (excluding those contributing to the aforementioned indices) were compared with a matched sample of 37 athletes who completed preseason baseline cognitive assessments in ImPACT (using the same criteria described above). Data from the ImPACT online version yielded 91.4% sensitivity and 69.1% specificity. For asymptomatic athletes suspected of hiding their concussion, data from ImPACT yielded 94.6% sensitivity and 97.3% specificity. The online version of the ImPACT tool is a valid measure of neurocognitive performance at the acute stages of concussion, with high levels of sensitivity and specificity, even when athletes appear to be denying postconcussion symptoms.
Dalmastri, Claudia; Pirone, Luisa; Tabacchioni, Silvia; Bevivino, Annamaria; Chiarini, Luigi
2005-05-01
In this study, we evaluated if recA species-specific PCR assays could be successfully applied to identify environmental isolates of the widespread Burkholderia cepacia complex (Bcc) species. A total of 729 Bcc rhizosphere isolates collected in different samplings were assigned to the species B. cepacia genomovar I (61), B. cenocepacia recA lineage IIIB (514), B. ambifaria (124) and B. pyrrocinia (30), by means of recA (RFLP) analysis, and PCR tests were performed to assess sensitivity and specificity of recA species-specific primers pairs. B. cepacia genomovar I specific primers produced the expected amplicon with all isolates of the corresponding species (sensitivity, 100%), and cross-reacted with all B. pyrrocinia isolates. On the contrary, B. cenocepacia IIIB primers did not give the expected amplicon in 164 B. cenocepacia IIIB isolates (sensitivity, 68.1%), and isolates of distinct populations showed different sensitivity. B. ambifaria primers failed to amplify a recA-specific fragment only in a few isolates of this species (sensitivity, 93.5%). The absence of specific amplification in a high number of B. cenocepacia rhizosphere isolates indicates that recA specific PCR assays can lead to an underestimation of environmental microorganisms belonging to this bacterial species.
Rehem, Tania Cristina Morais Santa Barbara; de Oliveira, Maria Regina Fernandes; Ciosak, Suely Itsuko; Egry, Emiko Yoshikawa
2013-01-01
To estimate the sensitivity, specificity and positive and negative predictive values of the Unified Health System's Hospital Information System for the appropriate recording of hospitalizations for ambulatory care-sensitive conditions. The hospital information system records for conditions which are sensitive to ambulatory care, and for those which are not, were considered for analysis, taking the medical records as the gold standard. Through simple random sampling, a sample of 816 medical records was defined and selected by means of a list of random numbers using the Statistical Package for Social Sciences. The sensitivity was 81.89%, specificity was 95.19%, the positive predictive value was 77.61% and the negative predictive value was 96.27%. In the study setting, the Hospital Information System (SIH) was more specific than sensitive, with nearly 20% of care sensitive conditions not detected. There are no validation studies in Brazil of the Hospital Information System records for the hospitalizations which are sensitive to primary health care. These results are relevant when one considers that this system is one of the bases for assessment of the effectiveness of primary health care.
Guerriero, S; Ajossa, S; Minguez, J A; Jurado, M; Mais, V; Melis, G B; Alcazar, J L
2015-11-01
To review the diagnostic accuracy of transvaginal ultrasound (TVS) in the preoperative detection of endometriosis in the uterosacral ligaments (USL), rectovaginal septum (RVS), vagina and bladder in patients with clinical suspicion of deep infiltrating endometriosis (DIE). An extensive search was performed in MEDLINE (PubMed) and EMBASE for studies published between January 1989 and December 2014. Studies were considered eligible if they reported on the use of TVS for the preoperative detection of endometriosis in the USL, RVS, vagina and bladder in women with clinical suspicion of DIE using the surgical data as a reference standard. Study quality was assessed using the PRISMA guidelines and QUADAS-2 tool. Of the 801 citations identified, 11 studies (n = 1583) were considered eligible and were included in the meta-analysis. For detection of endometriosis in the USL, the overall pooled sensitivity and specificity of TVS were 53% (95%CI, 35-70%) and 93% (95%CI, 83-97%), respectively. The pretest probability of USL endometriosis was 54%, which increased to 90% when suspicion of endometriosis was present after TVS examination. For detection of endometriosis in the RVS, the overall pooled sensitivity and specificity were 49% (95%CI, 36-62%) and 98% (95%CI, 95-99%), respectively. The pretest probability of RVS endometriosis was 24%, which increased to 89% when suspicion of endometriosis was present after TVS examination. For detection of vaginal endometriosis, the overall pooled sensitivity and specificity were 58% (95%CI, 40-74%) and 96% (95%CI, 87-99%), respectively. The pretest probability of vaginal endometriosis was 17%, which increased to 76% when suspicion of endometriosis was present after TVS assessment. Substantial heterogeneity was found for sensitivity and specificity for all these locations. For detection of bladder endometriosis, the overall pooled sensitivity and specificity were 62% (95%CI, 40-80%) and 100% (95%CI, 97-100%), respectively. Moderate heterogeneity was found for sensitivity and specificity for bladder endometriosis. The pretest probability of bladder endometriosis was 5%, which increased to 92% when suspicion of endometriosis was present after TVS assessment. Overall diagnostic performance of TVS for detecting DIE in uterosacral ligaments, rectovaginal septum, vagina and bladder is fair with high specificity. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Evaluation of Leishmania species reactivity in human serologic diagnosis of leishmaniasis.
Silvestre, Ricardo; Santarém, Nuno; Teixeira, Lúcia; Cunha, Joana; Schallig, Henk; Cordeiro-da-Silva, Anabela
2009-08-01
The sensitivities and specificities of IgG-ELISA and IgG flow cytometry based techniques using different Leishmania species were determined using sera collected from 40 cutaneous or visceral leishmaniasis patients. The flow cytometry technique, using promastigote parasite forms, performed better than total soluble extract IgG-ELISA. At the species level, the use of Leishmania amazonensis and Leishmania major as antigens in enzyme linked immunosorbent assay (ELISA) decreased the overall sensitivity. To assess the specificity of these tests, sera from malaria, toxoplasmosis, amoebiasis, schistosomiasis, and leprosy patients were used. We also included sera from Leishmania non-infected endemic individuals. The cutaneous species displayed a decreased specificity in both assays. Although more sensitive, flow cytometry using promastigote parasite forms generally presented lower levels of specificity when compared with total extract of IgG-ELISA. Overall, the results of the study show the potential of IgG flow cytometry for the diagnosis of leishmaniasis. Although highly sensitive, a refinement of the flow cytometry method should be performed to improve the overall specificity.
Larson, R N; Ginn, J A; Bell, C M; Davis, M J; Foy, D S
2012-01-01
The diagnosis of intestinal lymphangiectasia (IL) has been associated with characteristic duodenal mucosal changes. However, the sensitivity and specificity of the endoscopic duodenal mucosal appearance for the diagnosis of IL are not reported. To evaluate the utility of endoscopic images of the duodenum for diagnosis of IL. Endoscopic appearance of the duodenal mucosal might predict histopathologic diagnosis of IL with a high degree of sensitivity and specificity. 51 dogs that underwent upper gastrointestinal (GI) endoscopy and endoscopic biopsies. Retrospective review of images acquired during endoscopy. Dogs were included if adequate biopsies were obtained during upper GI endoscopy and digital images were saved during the procedure. Images were assessed for the presence and severity of IL. Using histopathology as the gold standard, the sensitivity and specificity of endoscopy for diagnosing IL were calculated. Intestinal lymphangiectasia (IL) was diagnosed in 25/51 dogs. Gross endoscopic appearance of the duodenal mucosa had a sensitivity and specificity (95% confidence interval) of 68% (46%, 84%) and 42% (24%, 63%), respectively for diagnosis of IL. Endoscopic images in cases with lymphopenia, hypocholesterolemia, and hypoalbuminemia had a sensitivity of 80%. Endoscopic duodenal mucosa appearance alone lacks specificity and has only a moderate sensitivity for diagnosis of IL. Evaluation of biomarkers associated with PLE improved the sensitivity; however, poor specificity for diagnosis of IL supports the need for histopathologic confirmation. Copyright © 2012 by the American College of Veterinary Internal Medicine.
Correcting the MoCA for education: effect on sensitivity.
Gagnon, Genevieve; Hansen, Kevin T; Woolmore-Goodwin, Sarah; Gutmanis, Iris; Wells, Jennie; Borrie, Michael; Fogarty, Jennifer
2013-09-01
The goal of this study was to quantify the impact of the suggested education correction on the sensitivity and specificity of the Montreal Cognitive Assessment (MoCA). Twenty-five outpatients with dementia and 39 with amnestic mild cognitive impairment (aMCI) underwent a diagnostic evaluation, which included the MoCA. Thirty-seven healthy controls also completed the MoCA and psychiatric, medical, neurological, functional, and cognitive difficulties were ruled out. For the total MoCA score, unadjusted for education, a cut-off score of 26 yielded the best balance between sensitivity and specificity (80% and 89% respectively) in identifying cognitive impairment (people with either dementia or aMCI, versus controls). When applying the education correction, sensitivity decreased from 80% to 69% for a small specificity increase (89% to 92%). The cut-off score yielding the best balance between sensitivity and specificity for the education adjusted MoCA score fell to 25 (61% and 97%, respectively). Adjusting the MoCA total score for education had a detrimental effect on sensitivity with only a slight increase in specificity. Clinically, this loss in sensitivity can lead to an increased number of false negatives, as education level does not always correlate to premorbid intellectual function. Clinical judgment about premorbid status should guide interpretation. However, as this effect may be cohort specific, age and education corrected norms and cut-offs should be developed to help guide MoCA interpretation.
Vallotton, Claire; Mastergeorge, Ann; Foster, Tricia; Decker, Kalli B.; Ayoub, Catherine
2016-01-01
Growing recognition of disparities in early childhood language environments prompt examination of parent-child interactions which support vocabulary. Research links parental sensitivity and cognitive stimulation to child language, but has not explicitly contrasted their effects, nor examined how effects may change over time. We examined maternal sensitivity and stimulation throughout infancy using two observational methods – ratings of parents’ interaction qualities, and coding of discrete parenting behaviors - to assess the relative importance of these qualities to child vocabulary over time, and determine whether mothers make related changes in response to children’s development. Participants were 146 infants and mothers, assessed when infants were 14, 24, and 36 months. At 14 months, sensitivity had a stronger effect on vocabulary than did stimulation, but the effect of stimulation grew throughout toddlerhood. Mothers’ cognitive stimulation grew over time, whereas sensitivity remained stable. While discrete parenting behaviors changed with child age, there was no evidence of trade-offs between sensitive and stimulating behaviors, and no evidence that sensitivity moderated the effect of stimulation on child vocabulary. Findings demonstrate specificity of timing in the link between parenting qualities and child vocabulary which could inform early parent interventions, and supports a reconceptualization of the nature and measurement of parental sensitivity. PMID:28111526
Tawa, Nassib; Rhoda, Anthea; Diener, Ina
2017-02-23
Lumbar radiculopathy remains a clinical challenge among primary care clinicians in both assessment and diagnosis. This often leads to misdiagnosis and inappropriate treatment of patients resulting in poor health outcomes, exacerbating this already debilitating condition. This review evaluated 12 primary diagnostic accuracy studies that specifically assessed the performance of various individual and grouped clinical neurological tests in detecting nerve root impingement, as established in the current literature. Eight electronic data bases were searched for relevant articles from inception until July 2016. All primary diagnostic studies which investigated the accuracy of clinical neurological test (s) in diagnosing lumbar radiculopathy among patients with low back and referred leg symptoms were screened for inclusion. Qualifying studies were retrieved and independently assessed for methodological quality using the 'Quality Assessment of Diagnostic tests Accuracy Studies' criteria. A total of 12 studies which investigated standard components of clinical neurological examination of (sensory, motor, tendon reflex and neuro-dynamics) of the lumbo-sacral spine were included. The mean inter-observer agreement on quality assessment by two independent reviewers was fair (k = 0.3 - 0.7). The diagnostic performance of sensory testing using MR imaging as a reference standard demonstrated a sensitivity (confidence interval 95%) 0.61 (0.47-0.73) and a specificity of 0.63 (0.38-0.84). Motor tests sensitivity was poor to moderate, ranging from 0.13 (0.04-0.31) to 0.61 (0.36-0.83). Generally, the diagnostic performance of reflex testing was notably good with specificity ranging from (confidence interval 95%) 0.60 (0.51-0.69) to 0.93 (0.87-0.97) and sensitivity ranging from 0.14 (0.09-0.21) to 0.67 (0.21-0.94). Femoral nerve stretch test had a high sensitivity of (confidence interval 95%) 1.00 (0.40-1.00) and specificity of 0.83 (0.52-0.98) while SLR test recorded a mean sensitivity of 0.84 (0.72-0.92) and specificity of 0.78 (0.67-0.87). There is a scarcity of studies on the diagnostic accuracy of clinical neurological examination testing. Furthermore there seem to be a disconnect among researchers regarding the diagnostic utility of lower limb neuro-dynamic tests which include the Straight Leg Raise and Femoral Nerve tests for sciatic and femoral nerve respectively. Whether these tests are able to detect the presence of disc herniation and subsequent nerve root compression or hyper-sensitivity of the sacral and femoral plexus due to mechanical irritation still remains debatable.
Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa
2017-11-01
Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.
Langenfeld, Matthias R; Forst, Thomas; Standl, Eberhard; Strotmann, Hermann-Josef; Lübben, Georg; Pahler, Sabine; Kann, Peter; Pfützner, Andreas
2004-12-01
This study was performed to compare the specificity and sensitivity of intact proinsulin, adiponectin, and their ratio (proinsulin/adiponectin) in the prediction of insulin resistance as assessed by the homeostasis model assessment (HOMA) score (> or =2 = resistant). Using a cross-sectional approach, 500 orally treated patients with type 2 diabetes (272 women, 238 men; mean +/- SD age, 64.8 +/- 11.6 years; hemoglobin A1c, 7.0 +/- 1.5%; disease duration, 5.8 +/- 6.1 years) were investigated. Various cutoffs for body mass index-adjusted adiponectin and proinsulin/adiponectin were compared with the established cutoff value of 10 pmol/L for fasting proinsulin. Fasting proinsulin correlated more closely with the HOMA score (r = 0.560, P < 0.001) than fasting adiponectin (r = -0.204, P < 0.001) or proinsulin/adiponectin (r = 0.355, P < 0.001). For proinsulin, specificity and sensitivity for insulin resistance in correlation to the HOMA score results were 96% and 70%, respectively. At a comparable specificity level to proinsulin, adiponectin did not reach a comparable sensitivity (14%), while the proinsulin/adiponectin ratio almost reached the same sensitivity (65%). Overall, patients with elevated proinsulin had a higher prevalence of micro- and macrovascular disease [odds ratio 1.47 (adiponectin, 1.08; proinsulin/ adiponectin, 1.48) and 1.34 (adiponectin, 1.32; proinsulin/adiponectin, 1.27), respectively]. Elevation of fasting intact proinsulin seems to be the more specific marker for insulin resistance and increased cardiovascular risk than suppression of fasting adiponectin. Formation of the ratio does not lead to a further increase in the predictive value.
Deepthi, R; Kasthuri, Arvind
2012-01-01
Hearing loss is a potentially disabling problem among elderly leading to physical and social dysfunction. Though audiometric assessment of hearing loss is considered as gold standard, it is not feasible in community settings. Several questionnaires measuring hearing handicap have been developed. Knowledge regarding applicability of these questionnaires among rural elderly is limited, hence a study was planned to validate single question and Shortened Hearing Handicap Inventory for Elderly (HHIE-S) in detecting hearing loss against pure tone-audiometry among rural Indian elderly. A single question 'do you feel you have a hearing loss?' and the HHIE-S was administered to 175 elderly in two rural areas. Hearing ability was assessed using pure tone audiometry. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of both screening tools were compared with pure tone averages (PTAs) greater than 25, 40 and 55 dB hearing level (mild, moderate and severe hearing loss, respectively). The single question yielded low sensitivity (30.9%) and high specificity (93.9%) for mild hearing loss. Similarly HHIE-S yielded a sensitivity of 26.2% and specificity of 95.9%. Sensitivity with single question increased to 76.2% and specificity decreased to 83.1% with severe hearing loss. Sensitivity with HHIE-S also increased to 76.2% and specificity decreased to 87.7% with severe hearing loss. These hearing screening questionnaires will be useful in identifying more disabling hearing losses among rural elderly which helps in rehabilitation services planning. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan
The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.
Kumar, Raj; Gupta, Nitesh; Kanuga, Jayesh; Kanuga, Mansi
2015-01-01
Skin prick testing (SPT) is the 'gold standard' in the assessment of allergic sensitivity to inhalant allergens. Serum-specific immunoglobulin E (SSIgE) measurement is a complementary test. SPT is performed with antigen extracts from India while SSIgE utilises extracts derived from European antigens. To evaluate the performance of allergic assessment by SSIgE against cockroach, housefly and mosquito aeroallergens which are frequently implicated in driving respiratory allergies in India considering SPT as the 'gold standard'. Twenty patients (mean age 28.5 years; range 15-50 years) diagnosed to have bronchial asthma and/or rhinitis underwent SPT. The SSIgE levels were obtained at the same visit. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SSIgE testing were calculated using SPT as the 'gold standard'. The correlation between SPT grading and SSIgE levels was also evaluated. The sensitivity of SSIgE testing to each of the 3 aero-allergens was > 85%. The PPV of cockroach and mosquito SSIgE was > 85%; housefly SSIgE had PPV of 68.7%. The two tests were in agreement in 85% (cockroach), 90% (mosquito) and 55% (housefly). There was a significant correlation between the grades of SPT reactions and SSIgE levels. The SSIgE has higher sensitivity and PPV, but lacks specificity. Higher sensitivity with low specificity leads to increased false positive diagnosis of allergic disease. Unlike allergenic pollens, however, insect antigen extracts from different regions seem to give comparable results, and can thus, reliably be used in the evaluation of allergy.
Development of responder criteria for multicomponent non-pharmacological treatment in fibromyalgia.
Vervoort, Vera M; Vriezekolk, Johanna E; van den Ende, Cornelia H
2017-01-01
There is a need to identify individual treatment success in patients with fibromyalgia (FM) who received non-pharmacological treatment. The present study described responder criteria for multicomponent non-pharmacological treatment in FM, and estimated and compared their sensitivity and specificity. Candidate responder sets were 1) identified in literature; and 2) formulated by expert group consensus. All candidate responder sets were tested in a cohort of 129 patients with FM receiving multicomponent non-pharmacological treatment. We used two gold standards (both therapist's and patient's perspective), assessed at six months after the start of treatment. Seven responder sets were defined (three identified in literature and four formulated by expert group consensus), and comprised combinations of domains of 1) pain; 2) fatigue; 3) patient global assessment (PGA); 4) illness perceptions; 5) limitations in activities of daily living (ADL); and 6) sleep. The sensitivity and specificity of literature-based responder sets (n=3) ranged between 17%-99% and 15%-95% respectively, whereas the expert-based responder sets (n=4) performed slightly better with regard to sensitivity (range 41%-81%) and specificity (range 50%-96%). Of the literature-based responder sets the OMERACT-OARSI responder set with patient's gold standard performed best (sensitivity 63%, specificity 75% and ROC area = 0.69). Overall, the expert-based responder set comprising the domains illness perceptions and limitations in ADL with patient's gold standard performed best (sensitivity 47%, specificity 96% and ROC area = 0.71). We defined sets of responder criteria for multicomponent non-pharmacological treatment in fibromyalgia. Further research should focus on the validation of those sets with acceptable performance.
Liu, Yan-chen; Huang, Ai-long; Hu, Yuan; Hu, Jie-li; Lai, Guo-qi; Zhang, Wen-lu
2011-12-01
To establish a detection method for HBV drug-resistant mutations related to lamivudine, adefovir and entecavir by optimization and assessment of reverse hybridization system. 26 degenerated probes covering 10 drug-resistant hotspots of 3 drugs were synthesized and immobilized on the same positively charged nylon membrane. PCR products labeled with digoxigenin were hybridized with corresponding probes. To improve the sensitivity and specificity, 4 reaction steps of reverse hybridization were optimized including the number of labeled digoxigenin, the energy intensity of UV cross-linking, hybridization and stringency wash conditions. To prove the feasibility, the specificity, sensitivity and accuracy of this system were assessed respectively. Sensitive and specific results are obtained by the optimization of the following 4 reaction steps: the primers labeled with 3 digoxigenin, energy intensity of UV cross-linking for 1500 x 0.1 mJ/cm², hybridization at 42 degrees C and stringency wash with 0.5 x SSC and 0.1% SDS solution at 44 degrees C for 30 min. In the assessment of system, the majority of probes have high specificity. The quantity of PCR product with a concentration of 10 ng/μl or above can be detected by this method. The concordant rate between reverse hybridization and direct sequencing is 93.9% in the clinical sample test. Though the specificity of several probes needs to be improved further, it is a simple, rapid and sensitive method which can detect HBV resistant mutations related to lamivudine, adefovir and entecavir simultaneously. Due to the short distance between 180 and 181, likewise 202 and 204, the sequence of the same probe covers two codon positions, and hybridization will be interfered by each other. To avoid such interference, the possible solution is that probes are designed by arranging and combining various forms of two near codons.
3D-CAM: Derivation and Validation of a 3-Minute Diagnostic Interview for CAM-defined Delirium
Marcantonio, Edward R.; Ngo, Long H.; O’Connor, Margaret; Jones, Richard N.; Crane, Paul K.; Metzger, Eran D.; Inouye, Sharon K.
2015-01-01
Background Delirium is common, morbid, and costly, yet remains often unrecognized in most clinical settings. The Confusion Assessment Method (CAM) is the most widely used diagnostic algorithm, and operationalizing its features would represent a substantial advance for clinical care. Objective To derive the 3D-CAM, a new 3-minute diagnostic assessment for CAM-defined delirium, and to validate it against a clinical reference standard. Design Diagnostic test study Setting 4 general medicine units in an academic medical center Participants 201 inpatients aged ≥ 75 years old Measurements We identified 20 items that best operationalized the 4 CAM diagnostic features to create the 3D-CAM. For prospective validation, 3D-CAM assessments were administered by trained research assistants. Independently, clinicians performed an extensive assessment that included patient interviews, family interviews, and review of the medical record. These data were considered by an expert panel to determine the presence or absence of delirium and dementia (reference standard). We compared the 3D-CAM delirium determination to the reference standard in all patients and in subgroups with and without dementia. Results The 201 participants in the prospective validation study had mean age (SD) of 84 (5.5) years, and 27% had dementia. The expert panel identified delirium in 21%. Median administration time for 3D-CAM was 3 minutes (inter-quartile range: 2–5 minutes). The sensitivity [95% CI] of 3D-CAM was 95% [84%, 99%] and the specificity was 94% [90%, 97%]. The 3D-CAM performed well in patients both with dementia (sensitivity=96% [82%, 100%], specificity=86% [67%, 96%]) and without dementia (sensitivity=93% [66%, 100%], specificity=96% [91%,99%]). Limitations Limited to single center, cross-sectional, and medicine patients only Conclusion The 3D-CAM operationalizes the CAM algorithm using a 3-minute structured assessment with high sensitivity and specificity relative to a reference standard and could be an important tool for improving recognition of delirium. PMID:25329203
Knipping, Karen; Simons, Peter J; Buelens-Sleumer, Laura S; Cox, Linda; den Hartog, Marcel; de Jong, Niels; Teshima, Reiko; Garssen, Johan; Boon, Louis; Knippels, Léon M J
2014-01-01
Cow's milk-derived whey hydrolysates are nutritional substitutes for allergic infants. Safety or residual allergenicity assessment of these whey hydrolysates is crucial. Currently, rat basophilic leukemia RBL-2H3 cells expressing the human IgE receptor α-chain (huFcεRIα-RBL-2H3), sensitized with serum IgE from cow's milk allergic children, are being employed to assess in vitro residual allergenicity of these whey hydrolysates. However, limited availability and inter-lot variation of these allergic sera impede standardization of whey hydrolysate safety testing in degranulation assays. An oligoclonal pool of chimeric human (chu)IgE antibodies against bovine β-lactoglobulin (a major allergen in whey) was generated to increase sensitivity, specificity, and reproducibility of existing degranulation assays. Mice were immunized with bovine β-lactoglobulin, and subsequently the variable domains of dissimilar anti-β-lactoglobulin mouse IgG antibodies were cloned and sequenced. Six chimeric antibodies were generated comprising mouse variable domains and human constant IgE/κ domains. After sensitization with this pool of anti-β-lactoglobulin chuIgEs, huFcεRIα-expressing RBL-2H3 cells demonstrated degranulation upon cross-linking with whey, native 18 kDa β-lactoglobulin, and 5-10 kDa whey hydrolysates, whereas a 3 kDa whey hydrolysate and cow's milk powder (mainly casein) showed no degranulation. In parallel, allergic serum IgEs were less sensitive. In addition, our pool anti-β-lactoglobulin chuIgEs recognized multiple allergenic immunodominant regions on β-lactoglobulin, which were also recognized by serum IgEs from cow's milk allergic children. Usage of our 'unlimited' source and well-defined pool of β-lactoglobulin-specific recombinant chuIgEs to sensitize huFcεRIα on RBL-2H3 cells showed to be a relevant and sensitive alternative for serum IgEs from cow's milk allergic patients to assess safety of whey-based non-allergic hydrolyzed formula.
Validity of self-assessment in a quality improvement collaborative in Ecuador.
Hermida, Jorge; Broughton, Edward I; Miller Franco, Lynne
2011-12-01
Health care quality improvement (QI) efforts commonly use self-assessment to measure compliance with quality standards. This study investigates the validity of self-assessment of quality indicators. Cross sectional. A maternal and newborn care improvement collaborative intervention conducted in health facilities in Ecuador in 2005. Four external evaluators were trained in abstracting medical records to calculate six indicators reflecting compliance with treatment standards. About 30 medical records per month were examined at 12 participating health facilities for a total of 1875 records. The same records had already been reviewed by QI teams at these facilities (self-assessment). Overall compliance, agreement (using the Kappa statistic), sensitivity and specificity were analyzed. We also examined patterns of disagreement and the effect of facility characteristics on levels of agreement. External evaluators reported compliance of 69-90%, while self-assessors reported 71-92%, with raw agreement of 71-95% and Kappa statistics ranging from fair to almost perfect agreement. Considering external evaluators as the gold standard, sensitivity of self-assessment ranged from 90 to 99% and specificity from 48 to 86%. Simpler indicators had fewer disagreements. When disagreements occurred between self-assessment and external valuators, the former tended to report more positive findings in five of six indicators, but this tendency was not of a magnitude to change program actions. Team leadership, understanding of the tools and facility size had no overall impact on the level of agreement. When compared with external evaluation (gold standard), self-assessment was found to be sufficiently valid for tracking QI team performance. Sensitivity was generally higher than specificity. Simplifying indicators may improve validity.
Atabek, Mehmet Emre; Pirgon, Ozgur
2007-02-01
Few previous studies have examined the validity of the fasting glucose-to-insulin ratio (FGIR), homeostasis model assessment of insulin resistance (HOMA-IR) and quantitative insulin-sensitivity check index (QUICKI) in pediatric populations. To compare simple indices of insulin resistance calculated from fasting glucose and insulin levels with insulin sensitivity indices (area under the response curve [AUCinsulin], insulin sensitivity index [ISI-compositeL) determined by oral glucose tolerance testing (OGTT) in obese children. One hundred and forty-eight obese children and adolescents (86 girls and 62 boys, mean age: 10.86 +/- 3.08 years, mean body mass index (BMI): 27.7 +/- 4.2) participated in the study. OGTT was performed in all participants. After glucose and insulin measurements from OGTT, the children were divided into two groups according to the presence or absence of insulin resistance. Insulin sensitivity indices obtained from the OGTT were compared between the groups. The total plasma glucose response and insulin secretion were evaluated from the AUC estimated by the trapezoid rule. Cut-off points, and sensitivity and specificity calculations were based on insulin resistance with receiver operating characteristic curve (ROC) analysis. The prevalence of insulin resistance, glucose intolerance and dyslipidemia was 37.1%, 24.3% and 54% in obese children, respectively. The groups consisted of 93 children without insulin resistance (54 girls and 39 boys; mean age: 10.5 +/- 3.3 years; mean BMI: 27.0 +/- 4.2) and 55 children with insulin resistance (32 girls and 23 boys; mean age: 11.4 +/- 2.5 years; mean BMI: 27.9 +/- 3.9). There were significant differences in mean FGIR (10.0 +/- 7.2 vs 5.6 +/- 2.8, p < 0.001), HOMA-IR (3.2 +/- 2.3 vs 4.9 +/- 2.3, p < 0.001) and QUICKI (0.33 +/- 0.03 vs 0.30 +/- 0.02, p < 0.001) between the groups. The cut-off points for diagnosis of insulin resistance were < 5.6 for FGIR (sensitivity 61.8, specificity 76.3), > 2.7 for HOMA-IR (sensitivity 80, specificity 59.1), and < 0.328 for QUICKI (sensitivity 80, specificity 60.2). Indices derived from fasting samples for diagnosis of insulin sensitivity are reliable criteria in obese children and adolescents. HOMA-IR and QUICKI appeared to have similar sensitivity and specificity and to have higher sensitivity than FGIR.
Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT.
Ciet, Pierluigi; Serra, Goffredo; Bertolo, Silvia; Spronk, Sandra; Ros, Mirco; Fraioli, Francesco; Quattrucci, Serena; Assael, M Baroukh; Catalano, Carlo; Pomerri, Fabio; Tiddens, Harm A W M; Morana, Giovanni
2016-03-01
To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100% (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). PROPELLER MRI does not match CT sensitivity to assess CF lung disease. PROPELLER MRI has lower sensitivity than CT to detect severe bronchiectasis. PROPELLER MRI has good to very good intra- and inter-observer variability. PROPELLER MRI can be used for short-term follow-up studies in CF.
Richman, Jesse; Zangalli, Camila; Lu, Lan; Wizov, Sheryl S; Spaeth, Eric; Spaeth, George L
2015-01-01
(1) To determine the ability of a novel, internet-based contrast sensitivity test titled the Spaeth/Richman Contrast Sensitivity Test (SPARCS) to identify patients with glaucoma. (2) To determine the test-retest reliability of SPARCS. A prospective, cross-sectional study of patients with glaucoma and controls was performed. Subjects were assessed by SPARCS and the Pelli-Robson chart. Reliability of each test was assessed by the intraclass correlation coefficient and the coefficient of repeatability. Sensitivity and specificity for identifying glaucoma was also evaluated. The intraclass correlation coefficient for SPARCS was 0.97 and 0.98 for Pelli-Robson. The coefficient of repeatability for SPARCS was ±6.7% and ±6.4% for Pelli-Robson. SPARCS identified patients with glaucoma with 79% sensitivity and 93% specificity. SPARCS has high test-retest reliability. It is easily accessible via the internet and identifies patients with glaucoma well. NCT01300949. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Sensitivity to scale of willingness-to-pay within the context of menorrhagia.
Sanghera, Sabina; Frew, Emma; Gupta, Janesh Kumar; Kai, Joe; Roberts, Tracy Elizabeth
2017-04-01
Willingness-to-pay (WTP) provides a broad assessment of well-being, capturing benefits beyond health. However, the validity of the approach has been questioned and the evidence relating to the sensitivity of WTP to changes in health status is mixed. Using menorrhagia (heavy menstrual bleeding) as a case study, this exploratory study assesses the sensitivity to scale of WTP to change in health status as measured by a condition-specific measure, MMAS, which includes both health and non-health benefits. The relationship between EQ-5D and change in health status is also assessed. Baseline EQ-5D and MMAS values were collected from women taking part in a randomized controlled trial for pharmaceutical treatment of menorrhagia. Following treatment, these measures were administered along with a WTP exercise. The relationship between the measures was assessed using Spearman's correlation analysis, and the sensitivity to scale of WTP was measured by identifying differences in WTP alongside differences in MMAS and EQ5D values. Our exploratory findings indicated that WTP, and not EQ-5D, was significantly positively correlated with change in MMAS, providing some evidence for convergent validity. These findings suggest that WTP is capturing the non-health benefits within the MMAS measure. Mean WTP also increased with percentage improvements in MMAS, suggesting sensitivity to scale. When compared to quality of life measured using the condition-specific MMAS measure, the convergent validity and sensitivity to scale of WTP is indicated. The findings suggest that WTP is more sensitive to change in MMAS, than with EQ-5D. © 2016 The Authors Health Expectations Published by John Wiley & Sons Ltd.
Baltzer, Pascal A T; Benndorf, Matthias; Dietzel, Matthias; Gajda, Mieczyslaw; Camara, Oumar; Kaiser, Werner A
2010-05-01
This study was performed to assess the sensitivity and specificity for malignant and benign mass lesions of a diagnostic approach combining DWI with T2-weighted images (unenhanced MR mammography, ueMRM) and compare the results with contrast-enhanced MR mammography (ceMRM). Consecutive patients undergoing histopathological verification of mass lesions after MR mammography without prior breast interventions (contrast-enhanced T1-weighted, T2-weighted and DWI sequences) were eligible for this retrospective investigation. Two blinded observers first rated ueMRM and then ceMRM according to the BIRADS scale. Lesion size, ADC values and T2-weighted TSE descriptors were assessed. This study examined 81 lesions (27 benign, 54 malignant). Sensitivity of ueMRM was 93% (observer 1) and 86% (observer 2), respectively. Sensitivity of ceMRM was 96.5% (observer 1) and 98.3% (observer 2). Specificity was 85.2% (ueMRM) and 92.6% (ceMRM) for both observers. The differences between both methods and observers were not significant (P > or = 0.09). Lesion size measurements did not differ significantly among all sequences analyzed. Tumor visibility was worse using ueMRM for both benign (P < 0.001) and malignant lesions (P = 0.004). Sensitivity and specificity of ueMRM in mass lesions equal that of ceMRM. However, a reduced lesion visibility in ueMRM may lead to more false-negative findings.
Cortes, Arthur Rodriguez Gonzalez; Eimar, Hazem; Barbosa, Jorge de Sá; Costa, Claudio; Arita, Emiko Saito; Tamimi, Faleh
2015-05-01
Subjective radiographic classifications of alveolar bone have been proposed and correlated with implant insertion torque (IT). The present diagnostic study aims to identify quantitative bone features influencing IT and to use these findings to develop an objective radiographic classification for predicting IT. Demographics, panoramic radiographs (taken at the beginning of dental treatment), and cone-beam computed tomographic scans (taken for implant surgical planning) of 25 patients receiving 31 implants were analyzed. Bone samples retrieved from implant sites were assessed with dual x-ray absorptiometry, microcomputed tomography, and histology. Odds ratio, sensitivity, and specificity of all variables to predict high peak IT were assessed. A ridge cortical thickness >0.75 mm and a normal appearance of the inferior mandibular cortex were the most sensitive variables for predicting high peak IT (87.5% and 75%, respectively). A classification based on the combination of both variables presented high sensitivity (90.9%) and specificity (100%) for predicting IT. Within the limitations of this study, the results suggest that it is possible to predict IT accurately based on radiographic findings of the patient. This could be useful in the treatment plan of immediate loading cases.
Assessment of nasalance and nasality in patients with a repaired cleft palate.
Sinko, Klaus; Gruber, Maike; Jagsch, Reinhold; Roesner, Imme; Baumann, Arnulf; Wutzl, Arno; Denk-Linnert, Doris-Maria
2017-07-01
In patients with a repaired cleft palate, nasality is typically diagnosed by speech language pathologists. In addition, there are various instruments to objectively diagnose nasalance. To explore the potential of nasalance measurements after cleft palate repair by NasalView ® , we correlated perceptual nasality and instrumentally measured nasalance of eight speech items and determined the relationship between sensitivity and specificity of the nasalance measures by receiver-operating characteristics (ROC) analyses and AUC (area under the curve) computation for each single test item and specific item groups. We recruited patients with a primarily repaired cleft palate receiving speech therapy during follow-up. During a single day visit, perceptive and instrumental assessments were obtained in 36 patients and analyzed. The individual perceptual nasality was assigned to one of four categories; the corresponding instrumental nasalance measures for the eight specific speech items were expressed on a metric scale (1-100). With reference to the perceptual diagnoses, we observed 3 nasal and one oral test item with high sensitivity. However, the specificity of the nasality indicating measures was rather low. The four best speech items with the highest sensitivity provided scores ranging from 96.43 to 100%, while the averaged sensitivity of all eight items was below 90%. We conclude that perceptive evaluation of nasality remains state of the art. For clinical follow-up, instrumental nasalance assessment can objectively document subtle changes by analysis of four speech items only. Further studies are warranted to determine the applicability of instrumental nasalance measures in the clinical routine, using discriminative items only.
Hermann, Olena; Schmidt, Simone B; Boltzmann, Melanie; Rollnik, Jens D
2018-05-01
To calculate scale performance of the newly developed Hessisch Oldendorf Fall Risk Scale (HOSS) for classifying fallers and non-fallers in comparison with the Risk of Falling Scale by Huhn (FSH), a frequently used assessment tool. A prospective observational trail was conducted. The study was performed in a large specialized neurological rehabilitation facility. The study population ( n = 690) included neurological and neurosurgery patients during neurological rehabilitation with varying levels of disability. Around the half of the study patients were independent and dependent in the activities of daily living (ADL), respectively. Fall risk of each patient was assessed by HOSS and FSH within the first seven days after admission. Event of fall during rehabilitation was compared with HOSS and FSH scores as well as the according fall risk. Scale performance including sensitivity and specificity was calculated for both scales. A total of 107 (15.5%) patients experienced at least one fall. In general, fallers were characterized by an older age, a prolonged length of stay, and a lower Barthel Index (higher dependence in the ADL) on admission than non-fallers. The verification of fall prediction for both scales showed a sensitivity of 83% and a specificity of 64% for the HOSS scale, and a sensitivity of 98% with a specificity of 12% for the FSH scale, respectively. The HOSS shows an adequate sensitivity, a higher specificity and therefore a better scale performance than the FSH. Thus, the HOSS might be superior to existing assessments.
Salmon, Stefanie J; Adriaanse, Marieke A; De Vet, Emely; Fennis, Bob M; De Ridder, Denise T D
2014-01-01
Self-control relies on a limited resource that can get depleted, a phenomenon that has been labeled ego-depletion. We argue that individuals may differ in their sensitivity to depleting tasks, and that consequently some people deplete their self-control resource at a faster rate than others. In three studies, we assessed individual differences in depletion sensitivity, and demonstrate that depletion sensitivity moderates ego-depletion effects. The Depletion Sensitivity Scale (DSS) was employed to assess depletion sensitivity. Study 1 employs the DSS to demonstrate that individual differences in sensitivity to ego-depletion exist. Study 2 shows moderate correlations of depletion sensitivity with related self-control concepts, indicating that these scales measure conceptually distinct constructs. Study 3 demonstrates that depletion sensitivity moderates the ego-depletion effect. Specifically, participants who are sensitive to depletion performed worse on a second self-control task, indicating a stronger ego-depletion effect, compared to participants less sensitive to depletion.
Salmon, Stefanie J.; Adriaanse, Marieke A.; De Vet, Emely; Fennis, Bob M.; De Ridder, Denise T. D.
2014-01-01
Self-control relies on a limited resource that can get depleted, a phenomenon that has been labeled ego-depletion. We argue that individuals may differ in their sensitivity to depleting tasks, and that consequently some people deplete their self-control resource at a faster rate than others. In three studies, we assessed individual differences in depletion sensitivity, and demonstrate that depletion sensitivity moderates ego-depletion effects. The Depletion Sensitivity Scale (DSS) was employed to assess depletion sensitivity. Study 1 employs the DSS to demonstrate that individual differences in sensitivity to ego-depletion exist. Study 2 shows moderate correlations of depletion sensitivity with related self-control concepts, indicating that these scales measure conceptually distinct constructs. Study 3 demonstrates that depletion sensitivity moderates the ego-depletion effect. Specifically, participants who are sensitive to depletion performed worse on a second self-control task, indicating a stronger ego-depletion effect, compared to participants less sensitive to depletion. PMID:25009523
Sjoholm-Gomez de Liano, Carl; Soberon-Ventura, Vidal F; Salcedo-Villanueva, Guillermo; Santos-Palacios, Abril; Guerrero-Naranjo, Jose Luis; Fromow-Guerra, Jans; García-Aguirre, Gerardo; Morales-Canton, Virgilio; Velez-Montoya, Raul
2017-01-01
To assess the sensitivity, specificity, positive predictive value and negative predictive value of anterior chamber tap for the diagnosis of bacterial endophthalmitis on a population with high prevalence. Retrospective, single centre, case series study. We reviewed all medical records with clinical diagnosis of bacterial endophthalmitis in our hospital from January 1st, 2000 to December 31st 2014. From each record, we documented general demographic data, best corrected visual acuity and vitreous and aqueous tap microbiological results. All cases were further divided according to the endophthalmitis aetiology to perform individual calculations of sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence. We used the results of the vitreous tap as the gold standard for diagnosis of bacterial endophthalmitis. We excluded those records in which the aqueous and vitreous samples were not taken simultaneously or had an incomplete microbiological report. Significance were assessed with chi squared statistics, with an alpha value of 0.05 for statistical significance. A total of 190 cases fulfilled the inclusion/exclusion criteria. Positive culture rate from vitreous samples was 64.74%. Positive culture rate from aqueous sample was 32.11%. Bacteria isolated from aqueous samples matched those isolated from vitreous samples 78.68% of the time. The overall sensitivity was 38.21%, specificity: 75.51%, positive predictive value: 79.66%, negative predictive value: 32.74% ( p = 0.08). Subgroup analysis showed that anterior chamber taps in cases of post-surgical endophthalmitis had a moderate to low sensitivity (37.73%), high specificity (93%) and high positive predictive value (95%) ( p < 0.04). The sensitivity and specificity of anterior chamber tap are low and should not be used for critical therapeutic decisions in patients with suspected bacterial endophthalmitis. In cases of post-surgical endophthalmitis, the result of an anterior chamber tap could be used for therapeutic guidance, but only in conjunction with clinical presentation and in the absence of a better method for diagnosis.
Leibowitz, David; Planer, David; Ben-Ibgi, Fanny; Rott, David; Weiss, A Teddy; Bursztyn, Michael
2007-02-01
Clinical echocardiographic assessment of left ventricular hypertrophy (LVH) is generally performed by measuring wall thickness alone (WT). The objective of this study was to compare the assessment of LVH using the measurement of WT to that using indexed LV mass. Hypertensive patients underwent echocardiography with the measurement of LV WT and LV mass. For each patient, the presence of LVH was assessed by both methods with WT compared to the gold standard of LV mass index. In all, 92 patients (51M/41F) were entered, and in only 55 patients (60%) were the two methods concordant. There was a tendency for WT to underestimate LVH in females (sensitivity 37%, specificity 79%) and overestimate LVH in males (sensitivity 88%, specificity 56%). The measurement of WT alone overestimates LVH in males and underestimates LVH in females and should not be used as a surrogate marker for increased LV mass.
Mkony, Martha Franklin; Mizinduko, Mucho Michael; Massawe, Augustine; Matee, Mecky
2014-12-05
We determined the accuracy of Rubarth's newborn scale of sepsis and C- reactive protein in diagnosing neonatal sepsis and assessed antimicrobial susceptibility pattern of etiological bacteria. This cross sectional study was conducted at Muhimbili National Hospital in Dar es Salaam, Tanzania between July 2012 and March 2013. Neonates suspected to have sepsis underwent physical examination using Rubarth's newborn scale of sepsis (RNSOS). Blood was taken for culture and antimicrobial sensitivity testing, full blood picture and C - reactive protein (CRP) performed 12 hours apart. The efficacy of RNSOS and serial CRP was assessed by calculating sensitivity, specificity, negative and positive predictive values, receiver operating characteristics (ROC) analysis as well as likelihood ratios (LHR) with blood culture result used as a gold standard. Out of 208 blood samples, 19.2% had a positive blood culture. Single CRP had sensitivity and specificity of 87.5% and 70.9% respectively, while RNSOS had sensitivity of 65% and specificity of 79.7%. Serial CRP had sensitivity of 69.0% and specificity of 92.9%. Combination of CRP and RNSOS increased sensitivity to 95.6% and specificity of 56.4%. Combination of two CRP and RNSOS decreased sensitivity to 89.1% but increased specificity to 74%. ROC for CRP was 0.86; and for RNSOS was 0.81. For CRP the LHR for positive test was 3 while for negative test was 0.18, while for RNSOS the corresponding values were 3.24 and for negative test was 0.43. Isolated bacteria were Klebsiella spp 14 (35%), Escherichia coli 12 (22.5%), Coagulase negative staphlococci 9 (30%), Staphylococcus aureus 4 (10%), and Pseudomonas spp 1 (2.5%). The overall resistance to the WHO recommended first line antibiotics was 100%, 92% and 42% for cloxacillin, ampicillin and gentamicin, respectively. For the second line drugs resistance was 45%, 40%, and 7% for ceftriaxone, vancomycin and amikacin respectively. Single CRP in combination with RNSOS can be used for rapid identification of neonates with sepsis due to high sensitivity (95.6%) but cannot exclude those without sepsis due to low specificity (56.4%). Serial CRP done 12hrs apart can be used to exclude non-cases. This study demonstrated very high levels of resistance to the first-line antibiotics.
Lau, Brian C; Collins, Michael W; Lovell, Mark R
2011-06-01
Concussions affect an estimated 136 000 high school athletes yearly. Computerized neurocognitive testing has been shown to be appropriately sensitive and specific in diagnosing concussions, but no studies have assessed its utility to predict length of recovery. Determining prognosis during subacute recovery after sports concussion will help clinicians more confidently address return-to-play and academic decisions. To quantify the prognostic ability of computerized neurocognitive testing in combination with symptoms during the subacute recovery phase from sports-related concussion. Cohort study (prognosis); Level of evidence, 2. In sum, 108 male high school football athletes completed a computer-based neurocognitive test battery within 2.23 days of injury and were followed until returned to play as set by international guidelines. Athletes were grouped into protracted recovery (>14 days; n = 50) or short-recovery (≤14 days; n = 58). Separate discriminant function analyses were performed using total symptom score on Post-Concussion Symptom Scale, symptom clusters (migraine, cognitive, sleep, neuropsychiatric), and Immediate Postconcussion Assessment and Cognitive Testing neurocognitive scores (verbal memory, visual memory, reaction time, processing speed). Multiple discriminant function analyses revealed that the combination of 4 symptom clusters and 4 neurocognitive composite scores had the highest sensitivity (65.22%), specificity (80.36%), positive predictive value (73.17%), and negative predictive value (73.80%) in predicting protracted recovery. Discriminant function analyses of total symptoms on the Post-Concussion Symptom Scale alone had a sensitivity of 40.81%; specificity, 79.31%; positive predictive value, 62.50%; and negative predictive value, 61.33%. The 4 symptom clusters alone discriminant function analyses had a sensitivity of 46.94%; specificity, 77.20%; positive predictive value, 63.90%; and negative predictive value, 62.86%. Discriminant function analyses of the 4 computerized neurocognitive scores alone had a sensitivity of 53.20%; specificity, 75.44%; positive predictive value, 64.10%; and negative predictive value, 66.15%. The use of computerized neurocognitive testing in conjunction with symptom clusters results improves sensitivity, specificity, positive predictive value, and negative predictive value of predicting protracted recovery compared with each used alone. There is also a net increase in sensitivity of 24.41% when using neurocognitive testing and symptom clusters together compared with using total symptoms on Post-Concussion Symptom Scale alone.
Validity of questions about activities of daily living to screen for dependency in older adults
Rebouças, Monica; Coelho-Filho, João Macedo; Veras, Renato Peixoto; Lima-Costa, Maria Fernanda; Ramos, Luiz Roberto
2017-01-01
ABSTRACT OBJECTIVE To determine the criterion validity of the activities of daily living present in functionality questionnaires in older adults for population surveys and to identify which activities are valid to quantify the real daily need for help of this population. METHODS This is a population sample of older adults stratified by levels of functionality, according to self-perception of dependency in the activities of daily living. Self-perception was compared with the gold standard – direct observation of these activities in the household of older adults by a trained professional, blinded to the answers in the questionnaire. At the visit, it was decided if the older adult needed help to perform any of the activities of daily living for the research. The sensitivity of each activity of daily living was greater when the self-assessment that there was no need for help coincided with the assessment of the professional. Specificity indicates coincidence regarding the need for help in the activities of daily living – coefficients of sensitivity and specificity above 70% were considered as indicative of good validity. RESULTS Self-assessments showed better sensitivity than specificity – older adults and observers agreed more on daily independency than on dependency. All activities showed sensitivity above 70%. Some activities had low (go shopping: 55%) or very low specificity (brush the hair: 33%). The best specificities were to take a shower and dress up (95.8% for both), among the personal ones, and to use transportation and perform banking transactions (78% for both), among the instrumental ones. CONCLUSIONS Activities of daily living can be valid indicators of functional dependence. The best coefficients of validity were generally obtained for personal activities. Some activities with good sensitivities and specificities – walk 100 meters, take a shower, and lie down in and get out of the bed – can be used to classify older adults into low, average, and high need for help depending on the affected activities and, therefore, can help in the planning of health services aimed at them. PMID:28876414
Ameye, Lieveke; Fischerova, Daniela; Epstein, Elisabeth; Melis, Gian Benedetto; Guerriero, Stefano; Van Holsbeke, Caroline; Savelli, Luca; Fruscio, Robert; Lissoni, Andrea Alberto; Testa, Antonia Carla; Veldman, Joan; Vergote, Ignace; Van Huffel, Sabine; Bourne, Tom; Valentin, Lil
2010-01-01
Objectives To prospectively assess the diagnostic performance of simple ultrasound rules to predict benignity/malignancy in an adnexal mass and to test the performance of the risk of malignancy index, two logistic regression models, and subjective assessment of ultrasonic findings by an experienced ultrasound examiner in adnexal masses for which the simple rules yield an inconclusive result. Design Prospective temporal and external validation of simple ultrasound rules to distinguish benign from malignant adnexal masses. The rules comprised five ultrasonic features (including shape, size, solidity, and results of colour Doppler examination) to predict a malignant tumour (M features) and five to predict a benign tumour (B features). If one or more M features were present in the absence of a B feature, the mass was classified as malignant. If one or more B features were present in the absence of an M feature, it was classified as benign. If both M features and B features were present, or if none of the features was present, the simple rules were inconclusive. Setting 19 ultrasound centres in eight countries. Participants 1938 women with an adnexal mass examined with ultrasound by the principal investigator at each centre with a standardised research protocol. Reference standard Histological classification of the excised adnexal mass as benign or malignant. Main outcome measures Diagnostic sensitivity and specificity. Results Of the 1938 patients with an adnexal mass, 1396 (72%) had benign tumours, 373 (19.2%) had primary invasive tumours, 111 (5.7%) had borderline malignant tumours, and 58 (3%) had metastatic tumours in the ovary. The simple rules yielded a conclusive result in 1501 (77%) masses, for which they resulted in a sensitivity of 92% (95% confidence interval 89% to 94%) and a specificity of 96% (94% to 97%). The corresponding sensitivity and specificity of subjective assessment were 91% (88% to 94%) and 96% (94% to 97%). In the 357 masses for which the simple rules yielded an inconclusive result and with available results of CA-125 measurements, the sensitivities were 89% (83% to 93%) for subjective assessment, 50% (42% to 58%) for the risk of malignancy index, 89% (83% to 93%) for logistic regression model 1, and 82% (75% to 87%) for logistic regression model 2; the corresponding specificities were 78% (72% to 83%), 84% (78% to 88%), 44% (38% to 51%), and 48% (42% to 55%). Use of the simple rules as a triage test and subjective assessment for those masses for which the simple rules yielded an inconclusive result gave a sensitivity of 91% (88% to 93%) and a specificity of 93% (91% to 94%), compared with a sensitivity of 90% (88% to 93%) and a specificity of 93% (91% to 94%) when subjective assessment was used in all masses. Conclusions The use of the simple rules has the potential to improve the management of women with adnexal masses. In adnexal masses for which the rules yielded an inconclusive result, subjective assessment of ultrasonic findings by an experienced ultrasound examiner was the most accurate diagnostic test; the risk of malignancy index and the two regression models were not useful. PMID:21156740
Zhai, Rong-Lin; Xu, Fei; Zhang, Pei; Zhang, Wan-Li; Wang, Hui; Wang, Ji-Liang; Cai, Kai-Lin; Long, Yue-Ping; Lu, Xiao-Ming; Tao, Kai-Xiong; Wang, Guo-Bin
2016-02-01
This meta-analysis was designed to evaluate the diagnostic performance of stool DNA testing for colorectal cancer (CRC) and compare the performance between single-gene and multiple-gene tests.MEDLINE, Cochrane, EMBASE databases were searched using keywords colorectal cancers, stool/fecal, sensitivity, specificity, DNA, and screening. Sensitivity analysis, quality assessments, and performance bias were performed for the included studies.Fifty-three studies were included in the analysis with a total sample size of 7524 patients. The studies were heterogeneous with regard to the genes being analyzed for fecal genetic biomarkers of CRC, as well as the laboratory methods being used for each assay. The sensitivity of the different assays ranged from 2% to 100% and the specificity ranged from 81% to 100%. The meta-analysis found that the pooled sensitivities for single- and multigene assays were 48.0% and 77.8%, respectively, while the pooled specificities were 97.0% and 92.7%. Receiver operator curves and diagnostic odds ratios showed no significant difference between both tests with regard to sensitivity or specificity.This meta-analysis revealed that using assays that evaluated multiple genes compared with single-gene assays did not increase the sensitivity or specificity of stool DNA testing in detecting CRC.
Elucidating uncertainty and sensitivity structures in environmental models can be a difficult task, even for low-order, single-medium constructs driven by a unique set of site-specific data. Quantitative assessment of integrated, multimedia models that simulate hundreds of sites...
Wearable technology and ECG processing for fall risk assessment, prevention and detection.
Melillo, Paolo; Castaldo, Rossana; Sannino, Giovanna; Orrico, Ada; de Pietro, Giuseppe; Pecchia, Leandro
2015-01-01
Falls represent one of the most common causes of injury-related morbidity and mortality in later life. Subjects with cardiovascular disorders (e.g., related to autonomic dysfunctions and postural hypotension) are at higher risk of falling. Autonomic dysfunctions increasing the risk of falling in the short and mid-term could be assessed by Heart Rate Variability (HRV) extracted by electrocardiograph (ECG). We developed three trials for assessing the usefulness of ECG monitoring using wearable devices for: risk assessment of falling in the next few weeks; prevention of imminent falls due to standing hypotension; and fall detection. Statistical and data-mining methods are adopted to develop classification and regression models, validated with the cross-validation approach. The first classifier based on HRV features enabled to identify future fallers among hypertensive patients with an accuracy of 72% (sensitivity: 51.1%, specificity: 80.2%). The regression model to predict falls due to orthostatic dropdown from HRV recorded before standing achieved an overall accuracy of 80% (sensitivity: 92%, specificity: 90%). Finally, the classifier to detect simulated falls using ECG achieved an accuracy of 77.3% (sensitivity: 81.8%, specificity: 72.7%). The evidence from these three studies showed that ECG monitoring and processing could achieve satisfactory performances compared to other system for risk assessment, fall prevention and detection. This is interesting as differently from other technologies actually employed to prevent falls, ECG is recommended for many other pathologies of later life and is more accepted by senior citizens.
Downey, Rachel I; Hutchison, Michael G; Comper, Paul
2018-06-14
To examine the clinical utility of the Sport Concussion Assessment Tool-3 (SCAT3) in university athletes with concussion in the absence and presence of baseline data over time. Athletes with concussion (n = 23) and uninjured controls (n = 22) were prospectively evaluated at three time-points (baseline, 3-5 days, 3 weeks post-injury) with the SCAT3 components: (1) Post-Concussion Symptom Scale (PCSS); (2) Standardized Assessment of Concussion (SAC); and (3) modified Balance Error Scoring System (m-BESS). Sensitivity and specificity were calculated using reliable change indices and normative data from 458 athletes who completed baseline testing. The PCSS total symptom score yielded highest sensitivity (47.4-72.2%) and specificity (78.6-91.7%) 3-5 days post-injury, with the SAC and m-BESS demonstrating little discriminative ability when used more than 3 days post-concussion. The utility of the SCAT3 was comparable when baseline or normative data was used for predicting concussion. The SCAT is a clinically useful tool for assessing concussion in the absence or presence of baseline data within the first 3-5 days post-injury. Clinical utility of the SCAT3 was driven by symptoms, which remains consistent in the SCAT5. Future research should explore whether additional cognitive elements in the SCAT5 improve utility beyond this timeframe.
Clinical case definition for the diagnosis of acute intussusception.
Bines, Julie E; Ivanoff, Bernard; Justice, Frances; Mulholland, Kim
2004-11-01
Because of the reported association between intussusception and a rotavirus vaccine, future clinical trials of rotavirus vaccines will need to include intussusception surveillance in the evaluation of vaccine safety. The aim of this study is to develop and validate a clinical case definition for the diagnosis of acute intussusception. A clinical case definition for the diagnosis of acute intussusception was developed by analysis of an extensive literature review that defined the clinical presentation of intussusception in 70 developed and developing countries. The clinical case definition was then assessed for sensitivity and specificity using a retrospective chart review of hospital admissions. Sensitivity of the clinical case definition was assessed in children diagnosed with intussusception over a 6.5-year period. Specificity was assessed in patients aged <2 years admitted with bowel obstruction and in patients aged <19 years presenting with symptoms that may occur in intussusception. The clinical case definition accurately identified 185 of 191 assessable cases as "probable" intussusception and six cases as "possible" intussusception (sensitivity, 97%). No case of radiologic or surgically proven intussusception failed to be identified by the clinical case definition. The specificity of the definition in correctly identifying patients who did not have intussusception ranged from 87% to 91%. The clinical case definition for intussusception may assist in the prompt identification of patients with intussusception and may provide an important tool for the future trials of enteric vaccines.
Validity and reliability of self-reported diabetes in the Atherosclerosis Risk in Communities Study.
Schneider, Andrea L C; Pankow, James S; Heiss, Gerardo; Selvin, Elizabeth
2012-10-15
The objective of this study was to assess the validity of prevalent and incident self-reported diabetes compared with multiple reference definitions and to assess the reliability (repeatability) of a self-reported diagnosis of diabetes. Data from 10,321 participants in the Atherosclerosis Risk in Communities (ARIC) Study who attended visit 4 (1996-1998) were analyzed. Prevalent self-reported diabetes was compared with reference definitions defined by fasting glucose and medication use obtained at visit 4. Incident self-reported diabetes was assessed during annual follow-up telephone calls and was compared with reference definitions defined by fasting glucose, hemoglobin A1c, and medication use obtained during an in-person visit attended by a subsample of participants (n = 1,738) in 2004-2005. The sensitivity of prevalent self-reported diabetes ranged from 58.5% to 70.8%, and specificity ranged from 95.6% to 96.8%, depending on the reference definition. Similarly, the sensitivity of incident self-reported diabetes ranged from 55.9% to 80.4%, and specificity ranged from 84.5% to 90.6%. Percent positive agreement of self-reported diabetes during 9 years of repeat assessments ranged from 92.7% to 95.4%. Both prevalent self-reported diabetes and incident self-reported diabetes were 84%-97% specific and 55%-80% sensitive as compared with reference definitions using glucose and medication criteria. Self-reported diabetes was >92% reliable over time.
Are 2 Questions Enough to Screen for Depression and Anxiety in Patients With Chronic Low Back Pain?
Lie, Stein Atle; Eriksen, Hege R.
2014-01-01
Study Design. Cross-sectional study. Objective. To examine the sensitivity of 2 single-item questions compared with 2 longer questionnaires for screening depression and anxiety among patients with chronic low back pain (CLBP). Summary of Background Data. Psychosocial factors are frequently identified as risk factors for developing CLBP and as predictors for treatment, and questionnaires are often used to screen for this. Shorter instruments may be easier to use in clinical practice settings. Methods. A total of 564 patients with 2 to 10 months of at least 50% sickness absence due to nonspecific low back pain were assessed for depression and anxiety with the Mini-International Neuropsychiatric Interview (MINI). Single-item questions for depression and anxiety from the Subjective Health Complaint Inventory and 2 longer questionnaires, the Hospital Anxiety and Depression Scale and Hopkins Symptom Checklist–25, were compared with MINI results, considered the “gold standard” in this study. Sensitivity and specificity of single-item and longer questionnaires and receiver operating characteristic curves were compared. Results. According to MINI, the prevalence of anxiety disorders was 12% whereas that of depressive disorders was 4%. The screening questions showed 95% sensitivity and 56% specificity for depressive disorders and 68% sensitivity and 85% specificity for anxiety disorders. The longer questionnaire, Hospital Anxiety and Depression Scale, showed 91% sensitivity and 85% specificity for depressive disorders and 58% sensitivity and 83% specificity for anxiety disorders. Hopkins Symptom Checklist–25 showed 86% sensitivity and 74% specificity for depressive disorders and 67% sensitivity and 87% specificity for anxiety disorders. For 3 of the anxiety disorders and 2 of the depressive disorders, a perfect sensitivity was found between the screening questions and MINI. Conclusions. A single-item screening question was sensitive for depression but less sensitive for anxiety. The screening questions further performed equal to 2 widely used questionnaires. Validation of these results in other populations and compared with other short-item screeners is needed. Level of Evidence: 3 PMID:24480946
Tillett, William; Costa, Luisa; Jadon, Deepak; Wallis, Dinny; Cavill, Charlotte; McHugh, Jessica; Korendowych, Eleanor; McHugh, Neil
2012-01-01
To evaluate the sensitivity, specificity, and feasibility of the ClASsification criteria for Psoriatic ARthritis (CASPAR) to retrospectively classify an existing research cohort. In total, 480 patient records were reviewed from the Royal National Hospital for Rheumatic Diseases Psoriatic Arthritis (PsA) cohort and for 100 consecutive controls with inflammatory arthritis from a general rheumatology clinic. The CASPAR score was modified for retrospective use; both "inflammation" and "current psoriasis" were recorded as present if they had ever been confirmed in the rheumatology clinic. Sensitivity and specificity of the CASPAR criteria were compared with expert clinical diagnosis. A total of 480 database records were identified. Nine sets of records had been lost or destroyed. The diagnoses had changed in 15 cases, which were transferred to the control arm, leaving 456 patients with an expert diagnosis of PsA. Of 115 controls, 96 had rheumatoid arthritis, 5 osteoarthritis, 3 reactive arthritis, 3 seronegative arthritis, 3 undifferentiated arthralgia, 2 ankylosing spondylitis, 1 spondyloarthritis, and 2 systemic sclerosis. Sensitivity (99.7%) and specificity (99.1%) were both high and equivalent to previous reports. Sensitivity remained high even after inclusion of 7 PsA patients with insufficient data to complete the CASPAR assessment (sensitivity 98.2%, specificity 99.1%). The criteria were found to be easy and practical to apply to case records. Our study demonstrates that the feasibility, specificity, and sensitivity of the CASPAR are maintained when adapted for retrospective use to classify an established research cohort.
The accuracy of burn diagnosis codes in health administrative data: A validation study.
Mason, Stephanie A; Nathens, Avery B; Byrne, James P; Fowler, Rob; Gonzalez, Alejandro; Karanicolas, Paul J; Moineddin, Rahim; Jeschke, Marc G
2017-03-01
Health administrative databases may provide rich sources of data for the study of outcomes following burn. We aimed to determine the accuracy of International Classification of Diseases diagnoses codes for burn in a population-based administrative database. Data from a regional burn center's clinical registry of patients admitted between 2006-2013 were linked to administrative databases. Burn total body surface area (TBSA), depth, mechanism, and inhalation injury were compared between the registry and administrative records. The sensitivity, specificity, and positive and negative predictive values were determined, and coding agreement was assessed with the kappa statistic. 1215 burn center patients were linked to administrative records. TBSA codes were highly sensitive and specific for ≥10 and ≥20% TBSA (89/93% sensitive and 95/97% specific), with excellent agreement (κ, 0.85/κ, 0.88). Codes were weakly sensitive (68%) in identifying ≥10% TBSA full-thickness burn, though highly specific (86%) with moderate agreement (κ, 0.46). Codes for inhalation injury had limited sensitivity (43%) but high specificity (99%) with moderate agreement (κ, 0.54). Burn mechanism had excellent coding agreement (κ, 0.84). Administrative data diagnosis codes accurately identify burn by burn size and mechanism, while identification of inhalation injury or full-thickness burns is less sensitive but highly specific. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Froyman, Wouter; Wynants, Laure; Landolfo, Chiara; Bourne, Tom; Valentin, Lil; Testa, Antonia; Sladkevicius, Povilas; Franchi, Dorella; Fischerova, Daniela; Savelli, Luca; Van Calster, Ben; Timmerman, Dirk
2017-06-02
The aim of this study was to assess and compare the performance of different ultrasound-based International Ovarian Tumor Analysis (IOTA) strategies and subjective assessment for the diagnosis of early stage ovarian malignancy. This is a secondary analysis of a prospective multicenter cross-sectional diagnostic accuracy study that included 1653 patients recruited at 18 centers from 2009 to 2012. All patients underwent standardized transvaginal ultrasonography by experienced ultrasound investigators. We assessed test performance of the IOTA Simple Rules (SRs), Simple Rules Risk (SRR), the Assessment of Different NEoplasias in the adneXa (ADNEX) model and subjective assessment to discriminate between stage I-II ovarian cancer and benign disease. Reference standard was histology after surgery. 230 (13.9%) patients proved to have stage I-II primary invasive ovarian malignancy, and 1423 (86.1%) had benign disease. Sensitivity and specificity with respect to malignancy (95% confidence intervals) of the original SRs (classifying all inconclusive cases as malignant) were 94.3% (90.6% to 96.7%) and 73.4% (71.0% to 75.6%). Subjective assessment had a sensitivity and specificity of 90.0% (85.4% to 93.2%) and 86.7% (84.9% to 88.4%), respectively. The areas under the receiver operator characteristic curves of SRR and ADNEX were 0.917 (0.902 to 0.933) and 0.905 (0.920 to 0.934), respectively. At a 1% risk cut-off, sensitivity and specificity for SRR were 100% (98.4% to 100%) and 38.0% (35.5% to 40.6%), and for ADNEX were 100% (98.4% to 100%) and 19.4% (17.4% to 21.5%). At a 30% risk cut-off, sensitivity and specificity for SRR were 88.3% (83.5% to 91.8%) and 81.1% (79% to 83%), and for ADNEX were 84.5% (80.5% to 89.6%) and 84.5% (82.6% to 86.3%). This study shows that all three IOTA strategies have good ability to discriminate between stage I-II ovarian malignancy and benign disease.
Local staging and assessment of colon cancer with 1.5-T magnetic resonance imaging
Blake, Helena; Jeyadevan, Nelesh; Abulafi, Muti; Swift, Ian; Toomey, Paul; Brown, Gina
2016-01-01
Objective: The aim of this study was to assess the accuracy of 1.5-T MRI in the pre-operative local T and N staging of colon cancer and identification of extramural vascular invasion (EMVI). Methods: Between 2010 and 2012, 60 patients with adenocarcinoma of the colon were prospectively recruited at 2 centres. 55 patients were included for final analysis. Patients received pre-operative 1.5-T MRI with high-resolution T2 weighted, gadolinium-enhanced T1 weighted and diffusion-weighted images. These were blindly assessed by two expert radiologists. Accuracy of the T-stage, N-stage and EMVI assessment was evaluated using post-operative histology as the gold standard. Results: Results are reported for two readers. Identification of T3 disease demonstrated an accuracy of 71% and 51%, sensitivity of 74% and 42% and specificity of 74% and 83%. Identification of N1 disease demonstrated an accuracy of 57% for both readers, sensitivity of 26% and 35% and specificity of 81% and 74%. Identification of EMVI demonstrated an accuracy of 74% and 69%, sensitivity 63% and 26% and specificity 80% and 91%. Conclusion: 1.5-T MRI achieved a moderate accuracy in the local evaluation of colon cancer, but cannot be recommended to replace CT on the basis of this study. Advances in knowledge: This study confirms that MRI is a viable alternative to CT for the local assessment of colon cancer, but this study does not reproduce the very high accuracy reported in the only other study to assess the accuracy of MRI in colon cancer staging. PMID:27226219
Machado, Michely Ediani; Tomazoni, Fernanda; Casarin, Maísa; Ardenghi, Thiago M; Zanatta, Fabricio Batistin
2017-10-01
To compare the performance of partial-mouth periodontal examination (PMPE) protocols with different cut-off points to the full-mouth examination (FME) in the assessment of the prevalence and extent of gingival bleeding in adolescents. A cross-sectional study was conducted involving 12-year-old adolescents. Following a systematic two-stage cluster sampling process, 1134 individuals were evaluated. Different PMPE protocols were compared to the FME with six sites per tooth. Sensitivity, specificity, area under the ROC curve (AUC), intraclass correlation coefficient (ICC), relative and absolute biases and the inflation factor were assessed for each PMPE protocol with different cut-off points for the severity of gingival bleeding. The highest AUC values were found for the six-site two-diagonal quadrant (2-4) (0.97), six-site random half-mouth (0.95) and Community Periodontal Index (0.95) protocols. The assessment of three sites [mesiobuccal (MB), buccal (B) and distolingual (DL)] in two diagonal quadrants and the random half-mouth protocol had higher sensitivity and lower specificity than the same protocols with distobuccal (DB) sites. However, the use of DB sites led to better specificity and improved the balance between sensitivity and specificity, except for the two-diagonal quadrant (1-3) protocol. The ≥1 cut-off point led to the most discrepant results from the FME. Six-site two-diagonal quadrant (2-4) and random half-mouth assessments perform better in the evaluation of gingival bleeding in adolescents. However, when a faster protocol is needed, a two-diagonal quadrant assessment using only MB, B and DL sites can be used with no important loss of information. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Four human Plasmodium species quantification using droplet digital PCR.
Srisutham, Suttipat; Saralamba, Naowarat; Malleret, Benoit; Rénia, Laurent; Dondorp, Arjen M; Imwong, Mallika
2017-01-01
Droplet digital polymerase chain reaction (ddPCR) is a partial PCR based on water-oil emulsion droplet technology. It is a highly sensitive method for detecting and delineating minor alleles from complex backgrounds and provides absolute quantification of DNA targets. The ddPCR technology has been applied for detection of many pathogens. Here the sensitive assay utilizing ddPCR for detection and quantification of Plasmodium species was investigated. The assay was developed for two levels of detection, genus specific for all Plasmodium species and for specific Plasmodium species detection. The ddPCR assay was developed based on primers and probes specific to the Plasmodium genus 18S rRNA gene. Using ddPCR for ultra-sensitive P. falciparum assessment, the lower level of detection from concentrated DNA obtained from a high volume (1 mL) blood sample was 11 parasites/mL. For species identification, in particular for samples with mixed infections, a duplex reaction was developed for detection and quantification P. falciparum/ P. vivax and P. malariae/ P. ovale. Amplification of each Plasmodium species in the duplex reaction showed equal sensitivity to singleplex single species detection. The duplex ddPCR assay had higher sensitivity to identify minor species in 32 subpatent parasitaemia samples from Cambodia, and performed better than real-time PCR. The ddPCR assay shows high sensitivity to assess very low parasitaemia of all human Plasmodium species. This provides a useful research tool for studying the role of the asymptomatic parasite reservoir for transmission in regions aiming for malaria elimination.
Kroghsbo, Stine; Rigby, Neil M.; Johnson, Philip E.; Adel-Patient, Karine; Bøgh, Katrine L.; Salt, Louise J.; Mills, E. N. Clare; Madsen, Charlotte B.
2014-01-01
Background IgE-binding of process-modified foods or proteins is the most common method for examination of how food processing affects allergenicity of food allergens. How processing affects sensitization capacity is generally studied by administration of purified food proteins or food extracts and not allergens present in their natural food matrix. Objectives The aim was to investigate if thermal processing increases sensitization potential of whole peanuts via the oral route. In parallel, the effect of heating on sensitization potential of the major peanut allergen Ara h 1 was assessed via the intraperitoneal route. Methods Sensitization potential of processed peanut products and Ara h 1 was examined in Brown Norway (BN) rats by oral administration of blanched or oil-roasted peanuts or peanut butter or by intraperitoneal immunization of purified native (N-), heated (H-) or heat glycated (G-)Ara h 1. Levels of specific IgG and IgE were determined by ELISA and IgE functionality was examined by rat basophilic leukemia (RBL) cell assay. Results In rats dosed orally, roasted peanuts induced significant higher levels of specific IgE to NAra h 1 and 2 than blanched peanuts or peanut butter but with the lowest level of RBL degranulation. However, extract from roasted peanuts was found to be a superior elicitor of RBL degranulation. Process-modified Ara h 1 had similar sensitizing capacity as NAra h 1 but specific IgE reacted more readily with process-modified Ara h 1 than with native. Conclusions Peanut products induce functional specific IgE when dosed orally to BN rats. Roasted peanuts do not have a higher sensitizing capacity than blanched peanuts. In spite of this, extract from roasted peanuts is a superior elicitor of RBL cell degranulation irrespectively of the peanut product used for sensitization. The results also suggest that new epitopes are formed or disclosed by heating Ara h 1 without glucose. PMID:24805813
Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S
2016-12-01
To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.
Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.
Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S
2014-02-10
Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.
Lewis, Jane Ea; Williams, Paul; Davies, Jane H
2016-01-01
This cross-sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (1) ankle brachial index and (2) pulse volume waveform analysis recorded by the same automated device, with the presence or absence of peripheral arterial disease being verified by ultrasound duplex scan. Patients (n=205) referred for lower limb arterial assessment underwent ankle brachial index measurement and pulse volume waveform recording using volume plethysmography, followed by ultrasound duplex scan. The presence of peripheral arterial disease was recorded if ankle brachial index <0.9; pulse volume waveform was graded as 2, 3 or 4; or if haemodynamically significant stenosis >50% was evident with ultrasound duplex scan. Outcome measure was agreement between the measured ankle brachial index and interpretation of pulse volume waveform for peripheral arterial disease diagnosis, using ultrasound duplex scan as the reference standard. Sensitivity of ankle brachial index was 79%, specificity 91% and overall accuracy 88%. Pulse volume waveform sensitivity was 97%, specificity 81% and overall accuracy 85%. The combined sensitivity of ankle brachial index and pulse volume waveform was 100%, specificity 76% and overall accuracy 85%. Combining these two diagnostic modalities within one device provided a highly accurate method of ruling out peripheral arterial disease, which could be utilised in primary care to safely reduce unnecessary secondary care referrals.
2016-01-01
Aim of this study was to evaluate the performance of saline hydrosonography (HSGM) (also known as saline infusion sonography (SIS)) against transvaginal ultrasound scan (TVS) and hysteroscopy in the diagnosis of uterine cavity lesions. Diagnostic hysteroscopy with biopsy is considered as the “gold standard” to diagnose intrauterine abnormalities. The introduction of HSGM has improved the diagnostic capability of ultrasound. It is important to establish the efficacy and safety of HSGM before it is widely recommended for use. This retrospective observational data was collected from all 223 patients who underwent TVS, HSGM, and hysteroscopy as part of their gynaecological investigations from 1 January 2008 to 31 December 2010 at Central Middlesex Hospital, London. Endometrial Polyps. TVS: sensitivity 60.53%, specificity 97.06%, positive predictive value (PPV) 95.83%, and negative predictive value (NPV) 68.75% and HSGM: sensitivity 95%, specificity 97.14%, PPV 97.44%, and NPV 94.44%. Submucous Leiomyoma. TVS: sensitivity 57.14%, specificity 93.48%, PPV 84.21%, and NPV 78.18% and HSGM: sensitivity 96.55%, specificity 100.00%, PPV 100.00%, and NPV 97.92%. Diagnostic efficacy of HSGM is superior to TVS for the diagnosis of endometrial polyps and submucous fibroids. HSGM should be considered as an intermediate investigation after TVS to assess intracavity pathology and to confirm the diagnosis; hysteroscopy should become a therapeutic intervention. PMID:27597989
Baracks, Joshua; Casa, Douglas J; Covassin, Tracey; Sacko, Ryan; Scarneo, Samantha E; Schnyer, David; Yeargin, Susan W; Neville, Christopher
2018-06-13
Without a true criterion standard assessment, the sport-related concussion (SRC) diagnosis remains subjective. Inertial balance sensors have been proposed to improve acute SRC assessment, but few researchers have studied their clinical utility. To determine if group differences exist when using objective measures of balance in a sample of collegiate athletes with recent SRCs and participants serving as the control group and to calculate sensitivity and specificity to determine the diagnostic utility of the inertial balance sensor for acute SRC injuries. Cohort study. Multicenter clinical trial. We enrolled 48 participants with SRC (age = 20.62 ± 1.52 years, height = 179.76 ± 10.00 cm, mass = 83.92 ± 23.22 kg) and 45 control participants (age = 20.85 ± 1.42 years, height = 177.02 ± 9.59 cm, mass = 74.61 ± 14.92 kg) at 7 clinical sites in the United States. All were varsity or club collegiate athletes, and all participants with SRC were tested within 72 hours of SRC. Balance performance was assessed using an inertial balance sensor. Two measures (root mean square [RMS] sway and 95% ellipse sway area) were analyzed to represent a range of general balance measures. Balance assessments were conducted in double-legged, single-legged, and tandem stances. A main effect for group was associated with the root mean square sway measure ( F 1,91 = 11.75, P = .001), with the SRC group demonstrating balance deficits compared with the control group. We observed group differences in the 95% ellipse sway area measure for the double-legged ( F 1,91 = 11.59, P = .001), single-legged ( F 1,91 = 6.91, P = .01), and tandem ( F 1,91 = 7.54, P = .007) stances. Sensitivity was greatest using a cutoff value of 0.5 standard deviations (54% [specificity = 71%]), whereas specificity was greatest using a cutoff value of 2 standard deviations (98% [sensitivity = 33%]). Inertial balance sensors may be useful tools for objectively measuring balance during acute SRC evaluation. However, low sensitivity suggests that they may be best used in conjunction with other assessments to form a comprehensive screening that may improve sensitivity.
Tagliafico, Alberto Stefano; Bignotti, Bianca; Rossi, Federica; Signori, Alessio; Sormani, Maria Pia; Valdora, Francesca; Calabrese, Massimo; Houssami, Nehmat
2016-08-01
To estimate sensitivity and specificity of CESM for breast cancer diagnosis. Systematic review and meta-analysis of the accuracy of CESM in finding breast cancer in highly selected women. We estimated summary receiver operating characteristic curves, sensitivity and specificity according to quality criteria with QUADAS-2. Six hundred four studies were retrieved, 8 of these reporting on 920 patients with 994 lesions, were eligible for inclusion. Estimated sensitivity from all studies was: 0.98 (95% CI: 0.96-1.00). Specificity was estimated from six studies reporting raw data: 0.58 (95% CI: 0.38-0.77). The majority of studies were scored as at high risk of bias due to the very selected populations. CESM has a high sensitivity but very low specificity. The source studies were based on highly selected case series and prone to selection bias. High-quality studies are required to assess the accuracy of CESM in unselected cases. Copyright © 2016 Elsevier Ltd. All rights reserved.
Bianchi, Kristin N; Carter, Michele M
2012-10-01
Disgust sensitivity and concern with contamination have been frequently associated with Spider and Blood-Injection-Injury (BII) Phobias. This study assessed the domain specificity of disgust sensitivity and concern with contamination in 29 Non-Phobic Controls, 25 clinical Spider Phobics, 26 clinical BII Phobics, and 27 persons who met clinical criteria for Spider Phobia and BII Phobia. On self-report measures we found evidence of domain specificity of disgust sensitivity for the Spider and BII Phobia groups. Furthermore, we found that persons with both phobias may be more disgust sensitive than persons with a single phobia. Interestingly, the animal reminder disgust stimulus used in this research was more sensitive to detecting domain specific differences in disgust sensitivity between Phobic groups than was the core disgust stimulus, emphasizing the importance of developing standardized behavioral measures of disgust sensitivity in future research. Lastly, findings from this research suggest that concern with contamination may be more influential in phobic avoidance for persons with Spider Phobia than for persons with BII Phobia. Treatment implications for these findings are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.
Arrhythmia discrimination by physician and defibrillator: importance of atrial channel.
Diemberger, Igor; Martignani, Cristian; Biffi, Mauro; Frabetti, Lorenzo; Valzania, Cinzia; Cooke, Robin M T; Rapezzi, Claudio; Branzi, Angelo; Boriani, Giuseppe
2012-01-26
Many ICD carriers experience inappropriate shocks, but the relative merits of dual- /single-chamber devices for arrhythmia discrimination still remain unclear. We explored possible advantages of the atrial data provided by dual-chamber implantable defibrillators (ICD) for discrimination of real-life supraventricular/ventricular tachyarrhythmias (SVT/VT). 100 dual-chamber traces from 24 ICD were blindly reviewed in dual-chamber and simulated single-chamber (with/without discriminator data) reading modes by five electrophysiologists who determined chamber of origin and provided Likert-scale "confidence" ratings. We assessed 1) intra/interobserver concordance; 2) diagnostic accuracy, using expert diagnoses as a reference standard; 3) ROC curves of sensitivity/specificity of "likelihood perception" scores, generated by combining chamber-of-origin diagnostic judgments with Likert-scale "confidence" ratings. We also assessed diagnostic accuracy of automated discrimination by all possible dual-/single-chamber algorithm configurations. Interobserver concordance was "substantial" (modified Cohen kappa-test values for dual-/single-chamber, 0.79/0.68); intraobserver concordance "almost complete" (kappa ≥ 0.89). Dual-chamber mode provided best diagnostic sensitivity/specificity (99%/92%) and highest reader confidence (p<0.001). Area under ROC curves of sensitivity/specificity values for the "likelihood perception" score (representing electrophysiologists' perceptions of the likelihood that an episode was of ventricular origin) was highest in dual-chamber mode (0.98 vs. 0.93 for both single-chamber modes; p<0.001). Regarding automated discrimination, all four dual-chamber configurations conferred 100% sensitivity (specificity values ranged 39%-88%), whereas single-chamber configurations appeared inferior (best sensitivity/specificity combination, 89%/64%). Availability of the atrial channel helps in reducing inappropriate ICD therapies by providing relevant advantages in terms of both appropriate cardiologist's post-hoc discrimination of SVT/VT (improving program tailoring) and automated arrhythmia discrimination. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Preoperative identification of a suspicious adnexal mass: a systematic review and meta-analysis.
Dodge, Jason E; Covens, Allan L; Lacchetti, Christina; Elit, Laurie M; Le, Tien; Devries-Aboud, Michaela; Fung-Kee-Fung, Michael
2012-07-01
To systematically review the existing literature in order to determine the optimal strategy for preoperative identification of the adnexal mass suspicious for ovarian cancer. A review of all systematic reviews and guidelines published between 1999 and 2009 was conducted as a first step. After the identification of a 2004 AHRQ systematic review on the topic, searches of MEDLINE for studies published since 2004 was also conducted to update and supplement the evidentiary base. A bivariate, random-effects meta-regression model was used to produce summary estimates of sensitivity and specificity and to plot summary ROC curves with 95% confidence regions. Four meta-analyses and 53 primary studies were included in this review. The diagnostic performance of each technology was compared and contrasted based on the summary data on sensitivity and specificity obtained from the meta-analysis. Results suggest that 3D ultrasonography has both a higher sensitivity and specificity when compared to 2D ultrasound. Established morphological scoring systems also performed with respectable sensitivity and specificity, each with equivalent diagnostic competence. Explicit scoring systems did not perform as well as other diagnostic testing methods. Assessment of an adnexal mass by colour Doppler technology was neither as sensitive nor as specific as simple ultrasonography. Of the three imaging modalities considered, MRI appeared to perform the best, although results were not statistically different from CT. PET did not perform as well as either MRI or CT. The measurement of the CA-125 tumour marker appears to be less reliable than do other available assessment methods. The best available evidence was collected and included in this rigorous systematic review and meta-analysis. The abundant evidentiary base provided the context and direction for the diagnosis of early-staged ovarian cancer. Copyright © 2012 Elsevier Inc. All rights reserved.
Computer-automated dementia screening using a touch-tone telephone.
Mundt, J C; Ferber, K L; Rizzo, M; Greist, J H
2001-11-12
This study investigated the sensitivity and specificity of a computer-automated telephone system to evaluate cognitive impairment in elderly callers to identify signs of early dementia. The Clinical Dementia Rating Scale was used to assess 155 subjects aged 56 to 93 years (n = 74, 27, 42, and 12, with a Clinical Dementia Rating Scale score of 0, 0.5, 1, and 2, respectively). These subjects performed a battery of tests administered by an interactive voice response system using standard Touch-Tone telephones. Seventy-four collateral informants also completed an interactive voice response version of the Symptoms of Dementia Screener. Sixteen cognitively impaired subjects were unable to complete the telephone call. Performances on 6 of 8 tasks were significantly influenced by Clinical Dementia Rating Scale status. The mean (SD) call length was 12 minutes 27 seconds (2 minutes 32 seconds). A subsample (n = 116) was analyzed using machine-learning methods, producing a scoring algorithm that combined performances across 4 tasks. Results indicated a potential sensitivity of 82.0% and specificity of 85.5%. The scoring model generalized to a validation subsample (n = 39), producing 85.0% sensitivity and 78.9% specificity. The kappa agreement between predicted and actual group membership was 0.64 (P<.001). Of the 16 subjects unable to complete the call, 11 provided sufficient information to permit us to classify them as impaired. Standard scoring of the interactive voice response-administered Symptoms of Dementia Screener (completed by informants) produced a screening sensitivity of 63.5% and 100% specificity. A lower criterion found a 90.4% sensitivity, without lowering specificity. Computer-automated telephone screening for early dementia using either informant or direct assessment is feasible. Such systems could provide wide-scale, cost-effective screening, education, and referral services to patients and caregivers.
Rosenthal, Eben L; Moore, Lindsay S; Tipirneni, Kiranya; de Boer, Esther; Stevens, Todd M; Hartman, Yolanda E; Carroll, William R; Zinn, Kurt R; Warram, Jason M
2017-08-15
Purpose: Comprehensive cervical lymphadenectomy can be associated with significant morbidity and poor quality of life. This study evaluated the sensitivity and specificity of cetuximab-IRDye800CW to identify metastatic disease in patients with head and neck cancer. Experimental Design: Consenting patients scheduled for curative resection were enrolled in a clinical trial to evaluate the safety and specificity of cetuximab-IRDye800CW. Patients ( n = 12) received escalating doses of the study drug. Where indicated, cervical lymphadenectomy accompanied primary tumor resection, which occurred 3 to 7 days following intravenous infusion of cetuximab-IRDye800CW. All 471 dissected lymph nodes were imaged with a closed-field, near-infrared imaging device during gross processing of the fresh specimens. Intraoperative imaging of exposed neck levels was performed with an open-field fluorescence imaging device. Blinded assessments of the fluorescence data were compared to histopathology to calculate sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV). Results: Of the 35 nodes diagnosed pathologically positive, 34 were correctly identified with fluorescence imaging, yielding a sensitivity of 97.2%. Of the 435 pathologically negative nodes, 401 were correctly assessed using fluorescence imaging, yielding a specificity of 92.7%. The NPV was determined to be 99.7%, and the PPV was 50.7%. When 37 fluorescently false-positive nodes were sectioned deeper (1 mm) into their respective blocks, metastatic cancer was found in 8.1% of the recut nodal specimens, which altered staging in two of those cases. Conclusions: Fluorescence imaging of lymph nodes after systemic cetuximab-IRDye800CW administration demonstrated high sensitivity and was capable of identifying additional positive nodes on deep sectioning. Clin Cancer Res; 23(16); 4744-52. ©2017 AACR . ©2017 American Association for Cancer Research.
Shi, Ruo-Yang; Yao, Qiu-Ying; Wu, Lian-Ming; Xu, Jian-Rong
2018-06-01
We compared the diagnostic performance of diffusion weighted imaging (DWI) acquired with 1.5T and 3.0T magnetic resonance (MR) units in differentiating malignant breast lesions from benign ones. A comprehensive search of the PubMed and Embase databases was performed for studies reported from January 1, 2000 to February 19, 2016. The quality of the included studies was assessed. Statistical analysis included pooling of diagnostic sensitivity and specificity and assessing data inhomogeneity and publication bias. A total of 61 studies were included after a full-text review. These included 4778 patients and 5205 breast lesions. The overall sensitivity and specificity were 90% (95% confidence interval [CI], 88%-92%) and 86% (95% CI, 82%-89%), respectively. The pooled diagnostic odds ratio was 53 (95% CI, 37-74). For breast cancer versus benign lesions, the area under the curve was 0.94 (95% CI, 0.92-0.96). For the 44 studies that used a 1.5T MR unit, the pooled sensitivity and specificity were 91% (95% CI, 89%-92%) and 86% (95% CI, 81%-90%), respectively. For the 17 studies that used a 3.0T MR unit, the pooled sensitivity and specificity were 88% (95% CI, 83%-91%) and 84% (95% CI, 0.78-0.89), respectively. Publication bias and significant heterogeneity were observed; however, no threshold was found among the 61 studies. No significant difference was found in the sensitivity or specificity between the subgroups. The results of the comparison between the subgroups that had used either a 1.5T or 3.0T MR unit suggest that the diagnostic accuracy for breast cancer compared with benign lesions is not significantly different. Copyright © 2017 Elsevier Inc. All rights reserved.
Kedia, Saurabh; Sharma, Raju; Sreenivas, Vishnubhatla; Madhusudhan, Kumble Seetharama; Sharma, Vishal; Bopanna, Sawan; Pratap Mouli, Venigalla; Dhingra, Rajan; Yadav, Dawesh Prakash; Makharia, Govind; Ahuja, Vineet
2017-04-01
Abdominal computed tomography (CT) can noninvasively image the entire gastrointestinal tract and assess extraintestinal features that are important in differentiating Crohn's disease (CD) and intestinal tuberculosis (ITB). The present meta-analysis pooled the results of all studies on the role of CT abdomen in differentiating between CD and ITB. We searched PubMed and Embase for all publications in English that analyzed the features differentiating between CD and ITB on abdominal CT. The features included comb sign, necrotic lymph nodes, asymmetric bowel wall thickening, skip lesions, fibrofatty proliferation, mural stratification, ileocaecal area, long segment, and left colonic involvements. Sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio (DOR) were calculated for all the features. Symmetric receiver operating characteristic curve was plotted for features present in >3 studies. Heterogeneity and publication bias was assessed and sensitivity analysis was performed by excluding studies that compared features on conventional abdominal CT instead of CT enterography (CTE). We included 6 studies (4 CTE, 1 conventional abdominal CT, and 1 CTE+conventional abdominal CT) involving 417 and 195 patients with CD and ITB, respectively. Necrotic lymph nodes had the highest diagnostic accuracy (sensitivity, 23%; specificity, 100%; DOR, 30.2) for ITB diagnosis, and comb sign (sensitivity, 82%; specificity, 81%; DOR, 21.5) followed by skip lesions (sensitivity, 86%; specificity, 74%; DOR, 16.5) had the highest diagnostic accuracy for CD diagnosis. On sensitivity analysis, the diagnostic accuracy of other features excluding asymmetric bowel wall thickening remained similar. Necrotic lymph nodes and comb sign on abdominal CT had the best diagnostic accuracy in differentiating CD and ITB.
Fiske-Jackson, A R; Barker, W H J; Eliashar, E; Foy, K; Smith, R K W
2013-01-01
The sensitivity of ultrasonography for the diagnosis of manica flexoria (MF) tears within the digital flexor tendon sheath (DFTS) is lower than for diagnosis of marginal tears of the deep digital flexor tendon (DDFT). Additional diagnostic tools would assist in appropriate decision making for either conservative or surgical management. To evaluate the improvement in lameness of horses with MF or DDFT tears following intrathecal analgesia and to assess the sensitivity and specificity of contrast radiography for the diagnosis of these tears. The case records of horses presented to a referral clinic over a 7-year period that underwent intrathecal diagnostic analgesia, or intrathecal analgesia and contrast radiography, of the DFTS with subsequent tenoscopy were examined. Fifty-three limbs had intrathecal diagnostic analgesia performed and 23 contrast tenograms were assessed in horses undergoing DFTS tenoscopy. Horses with DDFT tears were significantly more likely to respond positively to intrathecal diagnostic analgesia than those with MF tears (P = 0.02). Using contrast radiography, tears of the MF were predicted with an overall sensitivity of 96% and specificity of 80%; marginal tears of the DDFT were predicted with an overall sensitivity of 57% and specificity of 84%. The results of intrathecal analgesia of the DFTS in combination with contrast radiography have a high sensitivity for predicting MF tears. The sensitivity of contrast radiography for predicting tears of the DDFT is lower but the specificity remains high. Contrast radiography performed at the same time as intrathecal analgesia provides useful information regarding the presence of MF tears and DDFT tears, which can assist in the decision of whether to manage the lameness conservatively or with tenoscopic evaluation. © 2012 EVJ Ltd.
Kim, Nancy; Boone, Kyle B; Victor, Tara; Lu, Po; Keatinge, Carolyn; Mitchell, Cary
2010-08-01
Recently published practice standards recommend that multiple effort indicators be interspersed throughout neuropsychological evaluations to assess for response bias, which is most efficiently accomplished through use of effort indicators from standard cognitive tests already included in test batteries. The present study examined the utility of a timed recognition trial added to standard administration of the WAIS-III Digit Symbol subtest in a large sample of "real world" noncredible patients (n=82) as compared with credible neuropsychology clinic patients (n=89). Scores from the recognition trial were more sensitive in identifying poor effort than were standard Digit Symbol scores, and use of an equation incorporating Digit Symbol Age-Corrected Scaled Scores plus accuracy and time scores from the recognition trial was associated with nearly 80% sensitivity at 88.7% specificity. Thus, inclusion of a brief recognition trial to Digit Symbol administration has the potential to provide accurate assessment of response bias.
Robyn, M; Priyono, W B; Kim, L M; Brum, E
2012-06-01
A study was conducted to assess the diagnostic sensitivity and specificity of a disease surveillance method for diagnosis of highly pathogenic avian influenza (HPAI) outbreaks in household chicken flocks used by participatory disease surveillance (PDS) teams in Yogyakarta Province, Indonesia. The Government of Indonesia, in partnership with the Food and Agriculture Organization of the United Nations, has implemented a PDS method for the detection of HPAI outbreaks in poultry since 2006. The PDS method in Indonesia utilizes both a clinical case definition (CD) and the result of a commercial rapid antigen test kit Yogyakarta 55611, to diagnose HPAI outbreaks, primarily in backyard chicken flocks. The following diagnostic sensitivities and specificities were obtained relative to real-time reverse transcription-PCR as the gold standard diagnostic test: 1) 89% sensitivity (CI95: 75%-97%) and 96% specificity (CI95: 89%-99%) for the PDS CD alone; 2) 86% sensitivity (CI95: 71%-95%) and 99% specificity (CI95: 94%-100%) for the rapid antigen test alone; and 3) 84% sensitivity (CI95: 68%-94%) and 100% specificity (CI95: 96%-100%) for the PDS CD result combined with the rapid antigen test result. Based on these results, HPAI outbreaks in extensively raised household chickens can be diagnosed with sufficient sensitivity and specificity using the PDS method as implemented in Indonesia. Subject to further field evaluation, data from this study suggest that the diagnostic sensitivity of the PDS method may be improved by expanding the PDS CD to include more possible clinical presentations of HPAI and by increasing the number of rapid antigen tests to three different birds with HPAI-compatible signs of same flock.
Mertens, Paul LJM; Stals, Frans S; Steyerberg, Ewout W; Richardus, Jan H
2007-01-01
Background An accurate, practical laboratory test is needed to confirm clinical diagnosis of pertussis in adults during the first 3 symptomatic weeks, when treatment is effective and transmission can be interrupted. Methods The sensitivity and specificity of single IgA and IgG levels were assessed in a cohort study of a pertussis epidemic in 99 adults in a closed community. Sensitivities were assessed in the sera of 46 laboratory confirmed clinical pertussis cases during the first 3 weeks. Specificities were calculated in sera of 35 asymptomatic controls without clinical symptoms or laboratory confirmed infections from the same community (internal controls). We compared these specificities with the specificities of single IgA and IgG levels in 4275 external controls from a cross-section of the general Dutch population aged 21–79 years who had not coughed for more than 2 weeks in the past year, and without pertussis diagnoses. The study was done in the Netherlands when whole-cell pertussis vaccine was used in the national vaccination programme. Results Levels of 24 U/ml for IgA and 27 U/ml for IgG gave sensitivities of 100% and 75%, respectively, in the first 2 weeks, 100% in the third week, and 97% after the fourth week. The levels were reached within 2 days after onset of increase, and remained above these levels for roughly 7.2 and 5.1 months, respectively. Specificity was 82% for IgA and 89% for IgG in the internal controls and 90% in the external controls, respectively. Conclusion We suggest levels of 24 U/ml for IgA level and 27 U/ml (= 27 International Units (IU)/ml) for IgG as sensitive, specific, and practical for laboratory confirmation of clinical pertussis in adults in the first 3 weeks of outbreak management. PMID:17553132
Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Tanaka, Masato; Okuda, Akinori; Morimoto, Yasuhiko; Masuda, Keisuke; Yamamoto, Yusuke; Sakamoto, Yoshihiro; Koizumi, Munehisa; Tanaka, Yasuhito
2018-02-01
Case-control study. The aim of the present study was to identify physical findings useful for differentiating between cervical spondylotic amyotrophy (CSA) and rotator cuff tears to prevent the misdiagnosis of CSA as a rotator cuff tear. CSA and rotator cuff tears are often confused among patients presenting with difficulty in shoulder elevation. Twenty-five patients with CSA and 27 with rotator cuff tears were enrolled. We included five physical findings specific to CSA that were observed in both CSA and rotator cuff tear patients. The findings were as follows: (1) weakness of the deltoid muscle, (2) weakness of the biceps muscle, (3) atrophy of the deltoid muscle, (4) atrophy of the biceps muscle, and (5) swallow-tail sign (assessment of the posterior fibers of the deltoid). Among 25 CSA patients, 10 (40.0%) were misdiagnosed with a rotator cuff tear on initial diagnosis. The sensitivity and specificity of each physical finding were as follows: (1) deltoid weakness (sensitivity, 92.0%; specificity, 55.6%), (2) biceps weakness (sensitivity, 80.0%; specificity, 100%), (3) deltoid atrophy (sensitivity, 96.0%; specificity, 77.8%), (4) biceps atrophy (sensitivity, 88.8%; specificity, 92.6%), and (5) swallow-tail sign (sensitivity, 56.0%; specificity, 74.1%). There were statistically significant differences in each physical finding. CSA is likely to be misdiagnosed as a rotator cuff tear; however, weakness and atrophy of the biceps are useful findings for differentiating between CSA and rotator cuff tears to prevent misdiagnosis.
Electrocardiogram findings in emergency department patients with syncope.
Quinn, James; McDermott, Daniel
2011-07-01
To determine the sensitivity and specificity of the San Francisco Syncope Rule (SFSR) electrocardiogram (ECG) criteria for determining cardiac outcomes and to define the specific ECG findings that are the most important in patients with syncope. A consecutive cohort of emergency department (ED) patients with syncope or near syncope was considered. The treating emergency physicians assessed 50 predictor variables, including an ECG and rhythm assessment. For the ECG assessment, the physicians were asked to categorize the ECG as normal or abnormal based on any changes that were old or new. They also did a separate rhythm assessment and could use any of the ECGs or available monitoring strips, including prehospital strips, when making this assessment. All patients were followed up to determine a broad composite study outcome. The final ECG criterion for the SFSR was any nonsinus rhythm or new ECG changes. In this specific study, the initial assessments in the database were used to determine only cardiac-related outcomes (arrhythmia, myocardial infarction, structural, sudden death) based on set criteria, and the authors determined the sensitivity and specificity of the ECG criteria for cardiac outcomes only. All ECGs classified as "abnormal" by the study criteria were compared to the official cardiology reading to determine specific findings on the ECG. Univariate and multivariate analysis were used to determine important specific ECG and rhythm findings. A total of 684 consecutive patients were considered, with 218 having positive ECG criteria and 42 (6%) having important cardiac outcomes. ECG criteria predicted 36 of 42 patients with cardiac outcomes, with a sensitivity of 86% (95% confidence interval [CI] = 71% to 94%), a specificity of 70% (95% CI = 66% to 74%), and a negative predictive value of 99% (95% CI = 97% to 99%). Regarding specific ECG findings, any nonsinus rhythm from any source and any left bundle conduction problem (i.e., any left bundle branch block, left anterior fascicular block, left posterior fascicular block, or QRS widening) were 2.5 and 3.5 times more likely associated with significant cardiac outcomes. The ECG criteria from the SFSR are relatively simple, and if used correctly can help predict which patients are at risk of cardiac outcomes. Furthermore, any left bundle branch block conduction problems or any nonsinus rhythms found during the ED stay should be especially concerning for physicians caring for patients presenting with syncope. © 2011 by the Society for Academic Emergency Medicine.
Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A
2013-03-01
To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.
Computer-aided detection in musculoskeletal projection radiography: A systematic review.
Gundry, M; Knapp, K; Meertens, R; Meakin, J R
2018-05-01
To investigated the accuracy of computer-aided detection (CAD) software in musculoskeletal projection radiography via a systematic review. Following selection screening, eligible studies were assessed for bias, and had their study characteristics extracted resulting in 22 studies being included. Of these 22 three studies had tested their CAD software in a clinical setting; the first study investigated vertebral fractures, reporting a sensitivity score of 69.3% with CAD, compared to 59.8% sensitivity without CAD. The second study tested dental caries diagnosis producing a sensitivity score of 68.8% and specificity of 94.1% with CAD, compared to sensitivity of 39.3% and specificity of 96.7% without CAD. The third indicated osteoporotic cases based on CAD, resulting in 100% sensitivity and 81.3% specificity. The current evidence reported shows a lack of development into the clinical testing phase; however the research does show future promise in the variation of different CAD systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Luckett, Tim; King, Madeleine; Butow, Phyllis; Friedlander, Michael; Paris, Tim
2010-05-01
Researchers wishing to assess the health-related quality of life (HRQoL) of women with gynecologic cancers have a range of questionnaires to choose from. In general, disease-, treatment-, or symptom-specific questionnaires are assumed to be better able to identify between-group differences (sensitivity) and changes over time (responsiveness) than are cancer-specific or generic questionnaires. However, little work has tested this assumption in oncology. We set out to (a) identify all multidimensional HRQoL questionnaires used in studies with women with gynecologic cancer and (b) evaluate their track records in identifying minimal clinically important differences (MCIDs), with a view to making recommendations. We searched MEDLINE using the term quality of life and each gynecologic cancer type, as well as the names of identified questionnaires. We used 10% of the scale range as the threshold for an MCID. We identified 1 generic (SF-36/SF-12), 3 cancer-specific (European Organisation for the Research and Treatment of Cancer Quality of Life Questionnaire [EORTC QLQ] C30, Functional Assessment of Cancer Therapy-General [FACT-G], and short-form Cancer Rehabilitation Evaluation System [CARES-SF]), and 1 disease-specific (QOL-Ovarian Cancer Patient Version) HRQoL questionnaires and 5 disease-specific (QLQ-OV28, FACT-O for ovarian, QLQ-CX24, FACT-Cx for cervical and FACT-V for vulvar), 1 treatment-specific (FACT and Gynecologic Oncology Group-Ntx for neurotoxicity), and 2 symptom-specific (FACT-Anemia and Functional Assessment of Chronic Illness and Therapy [FACIT]-Fatigue) modules. Twenty-seven articles reported results from 26 studies in which an MCID had been identified. The FACIT's anemia and fatigue subscales were more sensitive, and the neurotoxicity subscale more sensitive and responsive than the FACT-G on at least 1 comparison. However, we found no evidence for superior performance by the FACT-G compared with the SF-36 or EORTC and FACIT disease-specific modules versus the QLQ-C30 and FACT-G. There was also little evidence to favor EORTC versus FACIT questionnaires or vice versa. The evidence we reviewed offered little support for the hypothesis that disease-, symptom-, or treatment-specific instruments are more sensitive and responsive than cancer-specific or generic questionnaires. However, conclusions were limited by the small number of head-to-head comparisons available. We summarize the clinical contexts in which each instrument identified an MCID to inform choice of questionnaire(s), sample size calculations, and interpretation of results in future studies.
Hamaker, Marije E; Jonker, Judith M; de Rooij, Sophia E; Vos, Alinda G; Smorenburg, Carolien H; van Munster, Barbara C
2012-10-01
Comprehensive geriatric assessment (CGA) is done to detect vulnerability in elderly patients with cancer so that treatment can be adjusted accordingly; however, this process is time-consuming and pre-screening is often used to identify fit patients who are able to receive standard treatment versus those in whom a full CGA should be done. We aimed to assess which of the frailty screening methods available show the best sensitivity and specificity for predicting the presence of impairments on CGA in elderly patients with cancer. We did a systematic search of Medline and Embase, and a hand-search of conference abstracts, for studies on the association between frailty screening outcome and results of CGA in elderly patients with cancer. Our search identified 4440 reports, of which 22 publications from 14 studies, were included in this Review. Seven different frailty screening methods were assessed. The median sensitivity and specificity of each screening method for predicting frailty on CGA were as follows: Vulnerable Elders Survey-13 (VES-13), 68% and 78%; Geriatric 8 (G8), 87% and 61%; Triage Risk Screening Tool (TRST 1+; patient considered frail if one or more impairments present), 92% and 47%, Groningen Frailty Index (GFI) 57% and 86%, Fried frailty criteria 31% and 91%, Barber 59% and 79%, and abbreviated CGA (aCGA) 51% and 97%. However, even in case of the highest sensitivity, the negative predictive value was only roughly 60%. G8 and TRST 1+ had the highest sensitivity for frailty, but both had poor specificity and negative predictive value. These findings suggest that, for now, it might be beneficial for all elderly patients with cancer to receive a complete geriatric assessment, since available frailty screening methods have insufficient discriminative power to select patients for further assessment. Copyright © 2012 Elsevier Ltd. All rights reserved.
Thissen, Monique; Udrea, Andreea; Hacking, Michelle; von Braunmuehl, Tanja; Ruzicka, Thomas
2017-12-01
With the advent of smartphone devices, an increasing number of mHealth applications that target melanoma identification have been developed, but none addresses the general context of melanoma and nonmelanoma skin cancer identification. In this study a smartphone application using fractal and classical image analysis for the risk assessment of skin lesions is systematically evaluated to determine its sensitivity and specificity in the diagnosis of melanoma and nonmelanoma skin cancer along with actinic keratosis and Bowen's disease. In the Department of Dermatology, Catharina Hospital Eindhoven, The Netherlands, 341 melanocytic and nonmelanocytic lesions were imaged using SkinVision app; 239 underwent histopathological examination, while the rest of 102 lesions were clinically diagnosed as clearly benign and not removed. The algorithm has been calibrated using the images of the first 233 lesions. The calibrated version of the algorithm was used in a subset of 108 lesions, and the obtained results were compared with the medical findings. On the 108 cases used for evaluation the algorithm scored 80% sensitivity and 78% specificity in detecting (pre)malignant conditions. Although less accurate than the dermatologist's clinical eye, the app may offer support to other professionals who are less familiar with differentiating between benign and malignant lesions. An mHealth application for the risk assessment of skin lesions was evaluated. It adds value to diagnosis tools of its type by taking into consideration pigmented and nonpigmented lesions all together and detecting signs of malignancy with high sensitivity.
Optimal search strategies for detecting health services research studies in MEDLINE
Wilczynski, Nancy L.; Haynes, R. Brian; Lavis, John N.; Ramkissoonsingh, Ravi; Arnold-Oatley, Alexandra E.
2004-01-01
Background Evidence from health services research (HSR) is currently thinly spread through many journals, making it difficult for health services researchers, managers and policy-makers to find research on clinical practice guidelines and the appropriateness, process, outcomes, cost and economics of health care services. We undertook to develop and test search terms to retrieve from the MEDLINE database HSR articles meeting minimum quality standards. Methods The retrieval performance of 7445 methodologic search terms and phrases in MEDLINE (the test) were compared with a hand search of the literature (the gold standard) for each issue of 68 journal titles for the year 2000 (a total of 25 936 articles). We determined sensitivity, specificity and precision (the positive predictive value) of the MEDLINE search strategies. Results A majority of the articles that were classified as outcome assessment, but fewer than half of those in the other categories, were considered methodologically acceptable (no methodologic criteria were applied for cost studies). Combining individual search terms to maximize sensitivity, while keeping specificity at 50% or more, led to sensitivities in the range of 88.1% to 100% for several categories (specificities ranged from 52.9% to 97.4%). When terms were combined to maximize specificity while keeping sensitivity at 50% or more, specificities of 88.8% to 99.8% were achieved. When terms were combined to maximize sensitivity and specificity while minimizing the differences between the 2 measurements, most strategies for HSR categories achieved sensitivity and specificity of at least 80%. Interpretation Sensitive and specific search strategies were validated for retrieval of HSR literature from MEDLINE. These strategies have been made available for public use by the US National Library of Medicine at www.nlm.nih.gov/nichsr/hedges/search.html. PMID:15534310
Verhoeven, C J M; Rückert, M E P F; Opmeer, B C; Pajkrt, E; Mol, B W J
2012-07-01
We performed a systematic review to determine whether sonographic assessment of occipital position of the fetal head can contribute to the prediction of the mode of delivery. We performed a systematic literature search of electronic databases from inception to May 2011. Two reviewers independently extracted data from the included studies. We used a bivariate model to estimate point estimates for sensitivity and specificity curves for the outcome Cesarean delivery. Eligible studies were cohort studies or cross-sectional studies that reported on both the position of the fetal head, as assessed by ultrasound, before or at the beginning of active labor as well as the outcome of labor in women at term. We included 11 primary articles reporting on 5053 women, of whom 898 had a Cesarean section. All studies indicated disappointing values for sensitivity and specificity in the prediction of Cesarean section. Summary point estimates of sensitivity and specificity were 0.39 (95% CI, 0.32-0.48) and 0.71 (95% CI, 0.67-0.74), respectively. Sonographic assessment of occipital position of the fetal head before delivery should not be used in the prediction of mode of delivery. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Rice, Karen C.; Bricker, Owen P.
1991-01-01
The report describes the results of a study to assess the sensitivity of streams to acidic deposition in Charles and Anne Arundel Counties, Maryland using a geology-based method. Water samples were collected from streams in July and August 1988 when streams were at base-flow conditions. Eighteen water samples collected from streams in Charles County, and 17 water samples from streams in Anne Arundel County were analyzed in the field for pH, specific conductance, and acid-neutralizing capacity (ANC); 8 water samples from streams in Charles County were analyzed in the laboratory for chloride and sulfate concentrations. The assessment revealed that streams in these counties are sensitive to acidification by acidic deposition.
Quantitative relationship between the local lymph node assay and human skin sensitization assays.
Schneider, K; Akkan, Z
2004-06-01
The local lymph node assay (LLNA) is a new test method which allows for the quantitative assessment of sensitizing potency in the mouse. Here, we investigate the quantitative correlation between results from the LLNA and two human sensitization tests--specifically, human repeat insult patch tests (HRIPTs) and human maximization tests (HMTs). Data for 57 substances were evaluated, of which 46 showed skin sensitizing properties in human tests, whereas 11 yielded negative results in humans. For better comparability data from mouse and human tests were transformed to applied doses per skin area, which ranged over four orders of magnitude for the substances considered. Regression analysis for the 46 human sensitizing substances revealed a significant positive correlation between the LLNA and human tests. The correlation was better between LLNA and HRIPT data (n=23; r=0.77) than between LLNA and HMT data (n=38; r=0.65). The observed scattering of data points is related to various uncertainties, in part associated with insufficiencies of data from older HMT studies. Predominantly negative results in the LLNA for another 11 substances which showed no skin sensitizing activity in human maximization tests further corroborate the correspondence between LLNA and human tests. Based on this analysis, the LLNA can be considered a reliable basis for relative potency assessments for skin sensitizers. Proposals are made for the regulatory exploitation of the LLNA: four potency groups can be established, and assignment of substances to these groups according to the outcome of the LLNA can be used to characterize skin sensitizing potency in substance-specific assessments. Moreover, based on these potency groups, a more adequate consideration of sensitizing substances in preparations becomes possible. It is proposed to replace the current single concentration limit for skin sensitizers in preparations, which leads to an all or nothing classification of a preparation as sensitizing to skin ("R43") in the European Union, by differentiated concentration limits derived from the limits for the four potency groups.
Kline, Kimberly N
2007-01-01
This study discusses the implications for cultural sensitivity of the rhetorical choices in breast cancer education materials developed specifically for African American audiences by national organizations. Using the PEN-3 model of cultural sensitivity as an analytic framework for a generative rhetorical criticism, this study revealed that adaptations have been made in some pamphlets to acknowledge African American cultural values related to community, self-reliance, spirituality, and distrust of the Western medical establishment, but many messages could be revised to achieve a more comprehensive, balanced, accurate, and audience-specific discussion of the breast cancer issue. Achieving cultural sensitivity in health promotion materials necessitates attention to nuanced meanings in messages, revision of questionable arguments and evidence, and avoidance of ambiguity.
Alcázar, Juan Luis; Gastón, Begoña; Navarro, Beatriz; Salas, Rocío; Aranda, Juana; Guerriero, Stefano
2017-11-01
To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting myometrial infiltration (MI) in endometrial carcinoma. An extensive search of papers comparing TVS and MRI in assessing MI in endometrial cancer was performed in MEDLINE (PubMed), Web of Science, and Cochrane Database from January 1989 to January 2017. Quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Our extended search identified 747 citations but after exclusions we finally included in the meta-analysis 8 articles. The risk of bias for most studies was low for most 4 domains assessed in QUADAS-2. Overall, pooled estimated sensitivity and specificity for diagnosing deep MI were 75% (95% confidence interval [CI]=67%-82%) and 82% (95% CI=75%-93%) for TVS, and 83% (95% CI=76%-89%) and 82% (95% CI=72%-89%) for MRI, respectively. No statistical differences were found when comparing both methods (p=0.314). Heterogeneity was low for sensitivity and high for specificity for TVS and MRI. MRI showed a better sensitivity than TVS for detecting deep MI in women with endometrial cancer. However, the difference observed was not statistically significant. Copyright © 2017. Asian Society of Gynecologic Oncology, Korean Society of Gynecologic Oncology
2017-01-01
Objective To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting myometrial infiltration (MI) in endometrial carcinoma. Methods An extensive search of papers comparing TVS and MRI in assessing MI in endometrial cancer was performed in MEDLINE (PubMed), Web of Science, and Cochrane Database from January 1989 to January 2017. Quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Results Our extended search identified 747 citations but after exclusions we finally included in the meta-analysis 8 articles. The risk of bias for most studies was low for most 4 domains assessed in QUADAS-2. Overall, pooled estimated sensitivity and specificity for diagnosing deep MI were 75% (95% confidence interval [CI]=67%–82%) and 82% (95% CI=75%–93%) for TVS, and 83% (95% CI=76%–89%) and 82% (95% CI=72%–89%) for MRI, respectively. No statistical differences were found when comparing both methods (p=0.314). Heterogeneity was low for sensitivity and high for specificity for TVS and MRI. Conclusion MRI showed a better sensitivity than TVS for detecting deep MI in women with endometrial cancer. However, the difference observed was not statistically significant. PMID:29027404
Pediatric medical complexity algorithm: a new method to stratify children by medical complexity.
Simon, Tamara D; Cawthon, Mary Lawrence; Stanford, Susan; Popalisky, Jean; Lyons, Dorothy; Woodcox, Peter; Hood, Margaret; Chen, Alex Y; Mangione-Smith, Rita
2014-06-01
The goal of this study was to develop an algorithm based on International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM), codes for classifying children with chronic disease (CD) according to level of medical complexity and to assess the algorithm's sensitivity and specificity. A retrospective observational study was conducted among 700 children insured by Washington State Medicaid with ≥1 Seattle Children's Hospital emergency department and/or inpatient encounter in 2010. The gold standard population included 350 children with complex chronic disease (C-CD), 100 with noncomplex chronic disease (NC-CD), and 250 without CD. An existing ICD-9-CM-based algorithm called the Chronic Disability Payment System was modified to develop a new algorithm called the Pediatric Medical Complexity Algorithm (PMCA). The sensitivity and specificity of PMCA were assessed. Using hospital discharge data, PMCA's sensitivity for correctly classifying children was 84% for C-CD, 41% for NC-CD, and 96% for those without CD. Using Medicaid claims data, PMCA's sensitivity was 89% for C-CD, 45% for NC-CD, and 80% for those without CD. Specificity was 90% to 92% in hospital discharge data and 85% to 91% in Medicaid claims data for all 3 groups. PMCA identified children with C-CD (who have accessed tertiary hospital care) with good sensitivity and good to excellent specificity when applied to hospital discharge or Medicaid claims data. PMCA may be useful for targeting resources such as care coordination to children with C-CD. Copyright © 2014 by the American Academy of Pediatrics.
Pediatric Medical Complexity Algorithm: A New Method to Stratify Children by Medical Complexity
Cawthon, Mary Lawrence; Stanford, Susan; Popalisky, Jean; Lyons, Dorothy; Woodcox, Peter; Hood, Margaret; Chen, Alex Y.; Mangione-Smith, Rita
2014-01-01
OBJECTIVES: The goal of this study was to develop an algorithm based on International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM), codes for classifying children with chronic disease (CD) according to level of medical complexity and to assess the algorithm’s sensitivity and specificity. METHODS: A retrospective observational study was conducted among 700 children insured by Washington State Medicaid with ≥1 Seattle Children’s Hospital emergency department and/or inpatient encounter in 2010. The gold standard population included 350 children with complex chronic disease (C-CD), 100 with noncomplex chronic disease (NC-CD), and 250 without CD. An existing ICD-9-CM–based algorithm called the Chronic Disability Payment System was modified to develop a new algorithm called the Pediatric Medical Complexity Algorithm (PMCA). The sensitivity and specificity of PMCA were assessed. RESULTS: Using hospital discharge data, PMCA’s sensitivity for correctly classifying children was 84% for C-CD, 41% for NC-CD, and 96% for those without CD. Using Medicaid claims data, PMCA’s sensitivity was 89% for C-CD, 45% for NC-CD, and 80% for those without CD. Specificity was 90% to 92% in hospital discharge data and 85% to 91% in Medicaid claims data for all 3 groups. CONCLUSIONS: PMCA identified children with C-CD (who have accessed tertiary hospital care) with good sensitivity and good to excellent specificity when applied to hospital discharge or Medicaid claims data. PMCA may be useful for targeting resources such as care coordination to children with C-CD. PMID:24819580
Rumpf, Hans-Jürgen; Hapke, Ulfert; Meyer, Christian; John, Ulrich
2002-01-01
Most screening questionnaires are developed in clinical settings and there are few data on their performance in the general population. This study provides data on the area under the receiver-operating characteristic (ROC) curve, sensitivity, specificity, and internal consistency of the Alcohol Use Disorders Identification Test (AUDIT), the consumption questions of the AUDIT (AUDIT-C) and the Lübeck Alcohol Dependence and Abuse Screening Test (LAST) among current drinkers (n = 3551) of a general population sample in northern Germany. Alcohol dependence and misuse according to DSM-IV and at-risk drinking served as gold standards to assess sensitivity and specificity and were assessed with the Munich-Composite Diagnostic Interview (M-CIDI). AUDIT and LAST showed insufficient sensitivity for at-risk drinking and alcohol misuse using standard cut-off scores, but satisfactory detection rates for alcohol dependence. The AUDIT-C showed low specificity in all criterion groups with standard cut-off. Adjusted cut-points are recommended. Among a subsample of individuals with previous general hospital admission in the last year, all questionnaires showed higher internal consistency suggesting lower reliability in non-clinical samples. In logistic regression analyses, having had a hospital admission increased the sensitivity in detecting any criterion group of the LAST, and the number of recent general practice visits increased the sensitivity of the AUDIT in detecting alcohol misuse. Women showed lower scores and larger areas under the ROC curves. It is concluded that setting specific instruments (e.g. primary care or general population) or adjusted cut-offs should be used.
de Camargo, Kélvia Cristina; Alves, Rosane Ribeiro Figueiredo; Baylão, Luciano Augusto; Ribeiro, Andrea Alves; Araujo, Nadja Lindany Alves de Souza; Tavares, Suelene Brito do Nascimento; dos Santos, Sílvia Helena Rabelo
2015-05-01
To estimate the prevalence of bacterial vaginosis (BV), candidiasis and trichomoniasis and compare the findings of physical examination of the vaginal secretion with the microbiological diagnosis obtained by cytology study of a vaginal smear using the Papanicolaou method. A cross-sectional study of 302 women aged 20 to 87 years, interviewed and submitted to a gynecology test for the evaluation of vaginal secretion and collection of a cytology smear, from June 2012 to May 2013. Sensitivity analyses were carried out and specificity, positive predictive value (PPV) and negative predictive value (NPV) with their respective 95%CI were determined to assess the accuracy of the characteristics of vaginal secretion in relation to the microbiological diagnosis of the cytology smear . The kappa index (k) was used to assess the degree of agreement between the clinical features of vaginal secretion and the microbiological findings obtained by cytology. RESULTS The prevalence of BV, candidiasis and trichomoniasis was 25.5, 9.3 and 2.0%, respectively. The sensitivity, specificity, PPV and NPV of the clinical characteristics of vaginal secretion for the cytological diagnosis of BV were 74, 78.6, 54.3 and 89.9%, respectively. The sensitivity, specificity, PPV and the NPV of the clinical characteristics of vaginal secretion for the cytological diagnosis of candidiasis were 46.4, 86.2, 25.5 and 94%, respectively. The correlation between the clinical evaluation of vaginal secretion and the microbiological diagnosis of BV, candidiasis and trichomoniasis, assessed by the kappa index, was 0.47, 0.23 and 0.28, respectively. CONCLUSION The most common cause of abnormal vaginal secretion was BV. The clinical evaluation of vaginal secretion presented amoderate to weak agreement with the microbiological diagnosis, indicating the need for complementary investigation of the clinical findings of abnormal vaginal secretion.
Use of point-of-care ultrasound in long bone fractures: a systematic review and meta-analysis.
Chartier, Lucas B; Bosco, Laura; Lapointe-Shaw, Lauren; Chenkin, Jordan
2017-03-01
Long bone fractures (LBFs) are among the most frequent traumatic injuries seen in emergency departments. Reduction and immobilization is the most common form of treatment for displaced fractures. Point-of-care ultrasound (PoCUS) is a promising technique for diagnosing LBFs and assessing the success of reduction attempts. This article offers a comprehensive review of the use of PoCUS for the diagnosis and reduction of LBFs. Data source MEDLINE and EMBASE databases were searched through July 19, 2015. Study selection We included prospective studies that assessed test characteristics of PoCUS in 1) the diagnosis or 2) the reduction of LBFs. The methodological quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data extraction Thirty studies met inclusion criteria (n=3,506; overall fracture rate 48.0%). Test characteristics of PoCUS for the diagnosis of LBFs were as follows: sensitivity 64.7%-100%, specificity 79.2%-100%, positive likelihood ratio (LR) 3.11-infinity, and negative LR zero-0.45. Sensitivity and specificity for the adequate reduction of LBFs with PoCUS were 94%-100% and 56%-100%, respectively. PoCUS diagnosis of pediatric forearm fractures in 10 studies showed a pooled sensitivity of 93.1% (95% confidence interval [CI], 87.2%-96.4%) and specificity of 92.9% (95% CI, 86.6%-96.4%), and PoCUS diagnosis of adult ankle fractures in four studies showed a pooled sensitivity of 89.5% (95% CI, 77.0%-95.6%) and specificity of 94.2% (95% CI, 86.1%-97.7%). PoCUS demonstrates good diagnostic accuracy in all LBFs studied, especially in pooled results of diagnosis of pediatric forearm and adult ankle fractures. PoCUS is an appropriate adjunct to plain radiographs for LBFs.
Mokhtarian, Kobra; Meamar, Ahmad Reza; Khoshmirsafa, Majid; Razmjou, Elham; Masoori, Leila; Khanmohammadi, Majid; Akhlaghi, Lame; Falak, Reza
2018-01-01
Laboratory diagnosis of sheep fasciolosis is commonly performed by coprological examinations; however, this method may lead to false negative results during the acute phase of the infection. Furthermore, the poor sensitivity of coprological methods is considered to be a paradox in the chronic phase of the infection. In this study, we compared the immunoreactivity of native and recombinant forms of Fasciola hepatica excretory/secretory antigens and determined their capabilities for the development of F. hepatica-specific immunoassays. Immunoreactivity and specificity of recombinant and native forms of F. hepatica antigens, including fatty acid binding protein (FABP), glutathione-S-transferase (GST), and cathepsin L-1 (CL1), in parallel with native forms of FABP and GST, were studied for serodiagnosis of the chronic form of sheep fasciolosis, individually or in combination with each other by enzyme-linked immunosorbent assays (ELISA). The correlation of the findings was assessed by receiver-operator characteristic (ROC); furthermore, the specificity and sensitivity were assessed by Youden's J. Serologic cross-reactivity was evaluated using samples from healthy sheep (n = 40), Fasciola-infected sheep (n = 30), and sheep with other parasitic infections (n = 43). The FABPs were determined to be greater than 95% sensitive for F. hepatica serodiagnosis. The most desirable diagnostic recombinant antigen was rCL1, which showed 100% sensitivity and 97% specificity in ELISA and was capable of discriminating the positive and negative samples by maximum Youden's J results. We conclude that rCL1 can be used for routine serodiagnosis of chronic fasciolosis. Thus, it could be advantageous in development of immunoassays for screening of ovine herds in fasciolosis-endemic areas and as a reliable agent for detection of fasciolosis in non-endemic regions.
Drewes, Christina; Sagberg, Lisa Millgård; Jakola, Asgeir Store; Gulati, Sasha; Solheim, Ole
2015-10-01
Published outcome reports in neurosurgical literature frequently rely on data from retrospective review of hospital records at discharge, but the sensitivity and specificity of retrospective assessments of surgical morbidity is not known. The aim of this study was to elucidate the sensitivity and specificity of retrospective assessment of morbidity after intracranial tumor surgery by comparing it to patient-reported outcomes at 30 days. In 191 patients who underwent surgery for the treatment of intracranial tumors, we evaluated newly acquired neurological deficits within the motor, language, and cognitive domains. Traditional retrospective discharge data were collected by review of hospital records. Patient-reported data were obtained by structured phone interviews at 30 days after surgery. Data on perioperative medical and surgical complications were obtained from both hospital records and patient interviews conducted 30 days postoperatively. Sensitivity values for retrospective review of hospital records as compared with patient-reported outcomes were 0.52 for motor deficits, 0.4 for language deficits, and 0.07 for cognitive deficits. According to medical records, 158 patients were discharged with no new or worsened deficits, but only 117 (74%) of these patients confirmed this at 30 days after surgery. Specificity values were high (0.97-0.99), indicating that new deficits were unlikely to be found by retrospective review of hospital records at discharge when the patients did not report any at 30 days. Major perioperative complications were all identified through retrospective review of hospital records. Retrospective assessment of medical records at discharge from hospital may greatly underestimate the incidence of new neurological deficits after brain tumor surgery when compared with patient-reported outcomes after 30 days.
Walter, Fiona M; Prevost, A Toby; Birt, Linda; Grehan, Nicola; Restarick, Kathy; Morris, Helen C; Sutton, Stephen; Rose, Peter; Downing, Sarah; Emery, Jon D
2013-01-01
Background Family history is an important risk factor for many common chronic diseases, but it remains underutilised for diagnostic assessment and disease prevention in routine primary care. Aim To develop and validate a brief self-completed family history questionnaire (FHQ) for systematic primary care assessment for family history of diabetes, ischaemic heart disease, breast cancer, and colorectal cancer. Design and setting Two-stage diagnostic validation study in 10 general practices in eastern England. Method Participants aged 18–50 years were identified via random sampling from electronic searches of general practice records. Participants completed a FHQ then had a three-generational ‘gold standard’ pedigree taken, to determine disease risk category. In stage 1, the FHQ comprised 12 items; in stage 2 the shorter 6-item FHQ was validated against the same ‘gold standard’. Results There were 1147 participants (stage 1: 618; stage 2: 529). Overall, 32% were at increased risk of one or more marker conditions (diabetes 18.9%, ischaemic heart disease 13.3%, breast cancer 6.2%, colorectal cancer 2.2%). The shorter 6-item FHQ performed very well for all four conditions: pooled data from both stages show diabetes, sensitivity = 98%, specificity = 94%; ischaemic heart disease, sensitivity = 93%, specificity = 81%; breast cancer, sensitivity = 81%, specificity = 83%; colorectal cancer, sensitivity = 96%, specificity = 88%, with an area under the receiver operating characteristic curve of 0.90 for males and 0.89 for females. Conclusion This brief self-completed FHQ shows good diagnostic accuracy for identifying people at higher risk of four common chronic diseases. It could be used in routine primary care to identify patients who would be most likely to benefit from a more detailed pedigree and risk assessment, and consequent management strategies. PMID:23735410
Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong
2017-10-01
Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.
APPROACHES TO ASSESSING THE VALIDITY OF A FUNCTIONAL OBSERVATIONAL BATTERY
With the growing importance of neurobehavioral assessments at the preliminary stage of chemical testing, it is critical that the screening procedures utilized be valid indicators of neurobehavioral dysfunction in addition to being sensitive, specific, and reliable. fforts in this...
Foong, Ru-Xin; Roberts, Graham; Fox, Adam Tobias; du Toit, George
2016-01-01
Children with atopic dermatitis (AD) are at risk of developing allergy. Alongside clinical history, testing modalities include skin prick tests (SPT), specific immunoglobulin-E (sp-IgE) and recently, microarray assays. The aim of this pilot study was to assess current tests and the ISAC sIgE-112 system in the diagnosis of food and aeroallergen allergy. Children aged 0-11 years with moderate to severe AD were included. An initial allergy assessment including clinical history, SPT and sp-IgE was performed to determine food and aeroallergen sensitization. A second independent clinical assessment using the same information given to the first assessor and ISAC test results for food and aeroallergen sensitization was also made for each participant. The results from both were compared. 30 children [mean age 3.91 years (SD 3.3)] were included; 53.3 and 46.7 % had moderate and severe AD, respectively. Sp-IgE tests had a higher percentage of positive results compared to SPT and ISAC tests for common allergens. There was a significant difference between the three tests in detecting aeroallergen sensitization (p = 0.038), especially between sp-IgE and ISAC tests, but no significant difference between the tests for food allergen sensitization. There was good agreement between the two assessors; 70 % of the children had a change in diagnosis, with 60 % having at least one diagnosis added and 40 % having at least one diagnosis removed. There is a role for the use of ISAC testing in diagnosing sensitization and allergy in children with AD as it leads to a change in diagnosis for many patients. Further work is required to assess its clinical and cost effectiveness.
The Half RR Rule: A Poor Rule of Thumb and Not a Risk Assessment Tool for QT Interval Prolongation.
Berling, Ingrid; Isbister, Geoffrey K
2015-10-01
Measuring the QT interval on an electrocardiogram (ECG) is integral to risk assessment of Torsade de Pointes (TdP). This study aimed to investigate the accuracy of the 1/2 RR rule as a risk assessment tool for drug-induced TdP, comparing it to the QT nomogram, Bazett's corrected QT (QTcB), and Fridericia's corrected QT (QTcF). The authors calculated sensitivity and specificity of the 1/2 RR rule using a published data set of 129 cases of drug-induced TdP and 316 controls (noncardiotoxic overdoses), compared to the QT nomogram, QTcB > 500 msec and QTcF > 500 msec. To further determine the value of the 1/2 RR rule, its observed positive, and negative agreement were calculated when compared to the QT nomogram for determining an abnormal QT in eight samples of different drugs in overdose. The sensitivity and specificity of the 1/2 RR rule were 88% (95% confidence interval [CI] = 80% to 93%) and 53% (95% CI = 47% to 58%), respectively, compared to the QT nomogram (sensitivity = 97%, 95% CI = 92% to 99%; specificity = 99%, 95% CI = 97% to 100%). It was also less sensitive than QTcB > 500 msec and had a lower specificity than QTcB > 500 msec and QTcF > 500 msec. In drug overdose patients, the 1/2 RR rule had poor observed agreement averaging 41%, which was mainly due to poor positive agreement, except for amisulpride where there was good agreement. The 1/2 RR rule was not as sensitive as the QT nomogram or QTcB > 500 msec for drug-induced TdP. It had poor positive agreement in almost all overdose patients, resulting in over half of patients receiving unnecessary cardiac monitoring and repeat ECGs. © 2015 by the Society for Academic Emergency Medicine.
Pakarinen, Harri; Flinkkilä, Tapio; Ohtonen, Pasi; Hyvönen, Pekka; Lakovaara, Martti; Leppilahti, Juhana; Ristiniemi, Jukka
2011-11-16
This study was designed to assess the sensitivity, specificity, and interobserver reliability of the hook test and the stress test for the intraoperative diagnosis of instability of the distal tibiofibular joint following fixation of ankle fractures resulting from supination-external rotation forces. We conducted a prospective study of 140 patients with an unstable unilateral ankle fracture resulting from a supination-external rotation mechanism (Lauge-Hansen SE). After internal fixation of the malleolar fracture, a hook test and an external rotation stress test under fluoroscopy were performed independently by the lead surgeon and assisting surgeon, followed by a standardized 7.5-Nm external rotation stress test of each ankle under fluoroscopy. A positive stress test result was defined as a side-to-side difference of >2 mm in the tibiotalar or the tibiofibular clear space on mortise radiographs. The sensitivity and specificity of each test were calculated with use of the standardized 7.5-Nm external rotation stress test as a reference. Twenty-four (17%) of the 140 patients had a positive standardized 7.5-Nm external rotation stress test after internal fixation of the malleolar fracture. The hook test had a sensitivity of 0.25 (95% confidence interval, 0.12 to 0.45) and a specificity of 0.98 (95% confidence interval, 0.94 to 1.0) for the detection of the same instabilities. The external rotation stress test had a sensitivity of 0.58 (95% confidence interval, 0.39 to 0.76) and a specificity of 0.96 (95% confidence interval, 0.90 to 0.98). Both tests had excellent interobserver reliability, with 99% agreement for the hook test and 98% for the stress test. Interobserver agreement for the hook test and the clinical stress test was excellent, but the sensitivity of these tests was insufficient to adequately detect instability of the syndesmosis intraoperatively.
Garway-Heath, David F; Quartilho, Ana; Prah, Philip; Crabb, David P; Cheng, Qian; Zhu, Haogang
2017-08-01
To evaluate the ability of various visual field (VF) analysis methods to discriminate treatment groups in glaucoma clinical trials and establish the value of time-domain optical coherence tomography (TD OCT) imaging as an additional outcome. VFs and retinal nerve fibre layer thickness (RNFLT) measurements (acquired by TD OCT) from 373 glaucoma patients in the UK Glaucoma Treatment Study (UKGTS) at up to 11 scheduled visits over a 2 year interval formed the cohort to assess the sensitivity of progression analysis methods. Specificity was assessed in 78 glaucoma patients with up to 11 repeated VF and OCT RNFLT measurements over a 3 month interval. Growth curve models assessed the difference in VF and RNFLT rate of change between treatment groups. Incident progression was identified by 3 VF-based methods: Guided Progression Analysis (GPA), 'ANSWERS' and 'PoPLR', and one based on VFs and RNFLT: 'sANSWERS'. Sensitivity, specificity and discrimination between treatment groups were evaluated. The rate of VF change was significantly faster in the placebo, compared to active treatment, group (-0.29 vs +0.03 dB/year, P <.001); the rate of RNFLT change was not different (-1.7 vs -1.1 dB/year, P =.14). After 18 months and at 95% specificity, the sensitivity of ANSWERS and PoPLR was similar (35%); sANSWERS achieved a sensitivity of 70%. GPA, ANSWERS and PoPLR discriminated treatment groups with similar statistical significance; sANSWERS did not discriminate treatment groups. Although the VF progression-detection method including VF and RNFLT measurements is more sensitive, it does not improve discrimination between treatment arms.
Subjective global assessment of nutritional status in children.
Mahdavi, Aida Malek; Ostadrahimi, Alireza; Safaiyan, Abdolrasool
2010-10-01
This study was aimed to compare the subjective and objective nutritional assessments and to analyse the performance of subjective global assessment (SGA) of nutritional status in diagnosing undernutrition in paediatric patients. One hundred and forty children (aged 2-12 years) hospitalized consecutively in Tabriz Paediatric Hospital from June 2008 to August 2008 underwent subjective assessment using the SGA questionnaire and objective assessment, including anthropometric and biochemical measurements. Agreement between two assessment methods was analysed by the kappa (κ) statistic. Statistical indicators including (sensitivity, specificity, predictive values, error rates, accuracy, powers, likelihood ratios and odds ratio) between SGA and objective assessment method were determined. The overall prevalence of undernutrition according to the SGA (70.7%) was higher than that by objective assessment of nutritional status (48.5%). Agreement between the two evaluation methods was only fair to moderate (κ = 0.336, P < 0.001). The sensitivity, specificity, positive and negative predictive value of the SGA method for screening undernutrition in this population were 88.235%, 45.833%, 60.606% and 80.487%, respectively. Accuracy, positive and negative power of the SGA method were 66.428%, 56.074% and 41.25%, respectively. Likelihood ratio positive, likelihood ratio negative and odds ratio of the SGA method were 1.628, 0.256 and 6.359, respectively. Our findings indicated that in assessing nutritional status of children, there is not a good level of agreement between SGA and objective nutritional assessment. In addition, SGA is a highly sensitive tool for assessing nutritional status and could identify children at risk of developing undernutrition. © 2009 Blackwell Publishing Ltd.
Corcoran, B; Linscott, L L; Leach, J L; Vadivelu, S
2016-05-01
Prior studies have found that widening or asymmetry of the occipital condyle-C1 interval on CT is a sensitive and specific marker for atlanto-occipital dislocation. Previously reported abnormal occipital condyle-C1 interval values are not age-specific, possibly leading to false-positive findings in younger children, in whom this joint space is normally larger than that in adults. This study assesses the utility of applying age-specific normative occipital condyle-C1 interval ranges to documented cases of atlanto-occipital injury compared with previously reported abnormal cutoff values. Retrospective review of CT and MR imaging of 14 subjects with atlanto-occipital injury was performed, and occipital condyle-C1 interval measurements were made for each subject. Sensitivities and specificities of proposed occipital condyle-C1 interval cutoffs of 2 and 3 SDs above the mean and previously published occipital condyle-C1 interval cutoffs for atlanto-occipital injury were then calculated on the basis of occipital condyle-C1 interval measurements for each subject. An occipital condyle-C1 interval 2 SDs above the age-specific mean has a sensitivity of 50% and specificity of 89%-100%, depending on the age group. An occipital condyle-C1 interval 3 SDs above the age-specific mean has a sensitivity of 50% and a specificity of 95%-100%. A 4.0-mm occipital condyle-C1 interval has a sensitivity of 36% and a specificity of 100% in all age groups. A 2.5-mm occipital condyle-C1 interval has a sensitivity of 93% and a specificity of 18%-100%. Occipital condyle-C1 interval widening cutoffs used to establish atlanto-occipital injury lack both sensitivity and specificity in children and young teenagers. MR imaging is necessary to establish a diagnosis of atlanto-occipital injury in children and young teenagers when the appropriate mechanism of injury is present. © 2016 by American Journal of Neuroradiology.
Use of the Dynamic Visual Acuity Test as a screener for community-dwelling older adults who fall.
Honaker, Julie A; Shepard, Neil T
2011-01-01
Adequate function of the peripheral vestibular system, specifically the vestibulo-ocular reflex (VOR; a network of neural connections between the peripheral vestibular system and the extraocular muscles) is essential for maintaining stable vision during head movements. Decreased visual acuity resulting from an impaired peripheral vestibular system may impede balance and postural control and place an individual at risk of falling. Therefore, sensitive measures of the vestibular system are warranted to screen for the tendency to fall, alerting clinicians to recommend further risk of falling assessment and referral to a falling risk reduction program. Dynamic Visual Acuity (DVA) testing is a computerized VOR assessment method to evaluate the peripheral vestibular system during head movements; reduced visual acuity as documented with DVA testing may be sensitive to screen for falling risk. This study examined the sensitivity and specificity of the computerized DVA test with yaw plane head movements for identifying community-dwelling adults (58-78 years) who are prone to falling. A total of 16 older adults with a history of two or more unexplained falls in the previous twelve months and 16 age and gender matched controls without a history of falls in the previous twelve months participated. Computerized DVA with horizontal head movements at a fixed velocity of 120 deg/sec was measured and compared with the Dynamic Gait Index (DGI) a gold standard gait assessment measurement for identifying falling risk. Receiver operating characteristics (ROC) curve analysis and area under the ROC curve (AUC) were used to assess the sensitivity and specificity of the computerized DVA as a screening measure for falling risk as determined by the DGI. Results suggested a link between computerized DVA and the propensity to fall; DVA in the yaw plane was found to be a sensitive (92%) and accurate screening measure when using a cutoff logMAR value of >0.25.
Computed tomography findings of acute gastric volvulus.
Millet, Ingrid; Orliac, Celine; Alili, Chakib; Guillon, Françoise; Taourel, Patrice
2014-12-01
To assess the diagnostic performance of CT signs of gastric volvulus in both confirmed cases and control subjects. We retrospectively reviewed CT findings in 10 patients with surgically confirmed acute gastric volvulus and 20 control subjects with gastric distension. Two radiologists independently evaluated CT images for risk factors of gastric volvulus, direct findings of gastric volvulus by assessing gastric dilatation, the presence of an antropyloric transition point, the respective position of the different stomach segments and of the greater and lesser curvatures, stenosis of the gastric segments through the oesophageal hiatus and for findings of gastric ischemia. The sensitivity and specificity of each finding were calculated. The most sensitive direct signs of gastric volvulus were an antropyloric transition point without any abnormality at the transition zone and the antrum at the same level or higher than the fundus. The presence of both these two findings as diagnostic criteria of gastric volvulus had 100% sensitivity and specificity for the diagnosis of gastric volvulus. There was no association between CT signs of ischemia and final bowel ischemia at pathology. CT is both highly sensitive and specific for diagnosing acute gastric volvulus. CT is highly reliable for diagnosing acute gastric volvulus with two findings. The two signs are gastropyloric transition zone and abnormal location of the antrum. This allows fast surgical management of this emergency.
Stressful Life Events, Anxiety Sensitivity, and Internalizing Symptoms in Adolescents
McLaughlin, Katie A.; Hatzenbuehler, Mark L.
2010-01-01
Anxiety sensitivity represents a robust risk factor for the development of anxiety symptoms among both adolescents and adults. However, the development of anxiety sensitivity among adolescents remains inadequately understood. In this study, the authors examined the role of stressful life events as a risk factor for the development of elevated anxiety sensitivity. Anxiety sensitivity was then examined in a longitudinal design as a mechanism linking stressful life events to changes in anxiety symptoms. Stressful life events, anxiety sensitivity, and internalizing symptoms were assessed in a diverse community sample of adolescents (N = 1,065) at 3 time points spanning 7 months. The results indicated that stressful life events were longitudinally associated with increases in anxiety sensitivity and that certain types of stressful life events, specifically events related to health and events related to family discord, were differentially predictive of increases in anxiety sensitivity. Moreover, anxiety sensitivity mediated the longitudinal relation between stressful life events and anxiety symptoms. Evidence was also found for the predictive specificity of anxiety sensitivity to symptoms of anxiety but not depression. PMID:19685962
Stressful life events, anxiety sensitivity, and internalizing symptoms in adolescents.
McLaughlin, Katie A; Hatzenbuehler, Mark L
2009-08-01
Anxiety sensitivity represents a robust risk factor for the development of anxiety symptoms among both adolescents and adults. However, the development of anxiety sensitivity among adolescents remains inadequately understood. In this study, the authors examined the role of stressful life events as a risk factor for the development of elevated anxiety sensitivity. Anxiety sensitivity was then examined in a longitudinal design as a mechanism linking stressful life events to changes in anxiety symptoms. Stressful life events, anxiety sensitivity, and internalizing symptoms were assessed in a diverse community sample of adolescents (N = 1,065) at 3 time points spanning 7 months. The results indicated that stressful life events were longitudinally associated with increases in anxiety sensitivity and that certain types of stressful life events, specifically events related to health and events related to family discord, were differentially predictive of increases in anxiety sensitivity. Moreover, anxiety sensitivity mediated the longitudinal relation between stressful life events and anxiety symptoms. Evidence was also found for the predictive specificity of anxiety sensitivity to symptoms of anxiety but not depression.
Stewart, Donna E; Dorado, Linda M; Diaz-Granados, Natalia; Rondon, Marta; Saavedra, Javier; Posada-Villa, Jose; Torres, Yolanda
2009-12-01
Gender inequities in health prevail in most countries despite ongoing attempts to eliminate them. Assessment of gender-sensitive health policies can be used to identify country specific progress as well as gaps and issues that need to be addressed to meet health equity goals. This study selected and measured the existence of gender-sensitive health policies in a low- (Peru), middle- (Colombia), and high (Canada)-income country in the Americas. Investigators selected 10 of 20 gender-sensitive health policy indicators and found eight to be feasible to measure in all three countries, although the wording and scope varied. The results from this study inform policy makers and program planners who aim to develop, improve, implement, and monitor national gender-sensitive health policies. Future studies should assess the implementation of policy indicators within countries and assess their performance in increasing gender equity.
Register-Mihalik, Johna K; Guskiewicz, Kevin M; Mihalik, Jason P; Schmidt, Julianne D; Kerr, Zachary Y; McCrea, Michael A
2013-01-01
To provide reliable change confidence intervals for common clinical concussion measures using a healthy sample of collegiate athletes and to apply these reliable change parameters to a sample of concussed collegiate athletes. Two independent samples were included in the study and evaluated on common clinical measures of concussion. The healthy sample included male, collegiate football student-athletes (n = 38) assessed at 2 time points. The concussed sample included college-aged student-athletes (n = 132) evaluated before and after a concussion. Outcome measures included symptom severity scores, Automated Neuropsychological Assessment Metrics throughput scores, and Sensory Organization Test composite scores. Application of the reliable change parameters suggests that a small percentage of concussed participants were impaired on each measure. We identified a low sensitivity of the entire battery (all measures combined) of 50% but high specificity of 96%. Clinicians should be trained in understanding clinical concussion measures and should be aware of evidence suggesting the multifaceted battery is more sensitive than any single measure. Clinicians should be cautioned that sensitivity to balance and neurocognitive impairments was low for each individual measure. Applying the confidence intervals to our injured sample suggests that these measures do not adequately identify postconcussion impairments when used in isolation.
Carlton, Joshua A; Maxwell, Adam W; Bauer, Lyndsey B; McElroy, Sara M; Layfield, Lester J; Ahsan, Humera; Agarwal, Ajay
2017-06-01
Background and purpose In patients with squamous cell carcinoma of the head and neck (HNSCC), extracapsular spread (ECS) of metastases in cervical lymph nodes affects prognosis and therapy. We assessed the accuracy of intravenous contrast-enhanced computed tomography (CT) and the utility of imaging criteria for preoperative detection of ECS in metastatic cervical lymph nodes in patients with HNSCC. Materials and methods Preoperative intravenous contrast-enhanced neck CT images of 93 patients with histopathological HNSCC metastatic nodes were retrospectively assessed by two neuroradiologists for ECS status and ECS imaging criteria. Radiological assessments were compared with histopathological assessments of neck dissection specimens, and interobserver agreement of ECS status and ECS imaging criteria were measured. Results Sensitivity, specificity, positive predictive value, and accuracy for overall ECS assessment were 57%, 81%, 82% and 67% for observer 1, and 66%, 76%, 80% and 70% for observer 2, respectively. Correlating three or more ECS imaging criteria with histopathological ECS increased specificity and positive predictive value, but decreased sensitivity and accuracy. Interobserver agreement for overall ECS assessment demonstrated a kappa of 0.59. Central necrosis had the highest kappa of 0.74. Conclusion CT has moderate specificity for ECS assessment in HNSCC metastatic cervical nodes. Identifying three or more ECS imaging criteria raises specificity and positive predictive value, therefore preoperative identification of multiple criteria may be clinically useful. Interobserver agreement is moderate for overall ECS assessment, substantial for central necrosis. Other ECS CT criteria had moderate agreement at best and therefore should not be used individually as criteria for detecting ECS by CT.
Attallah, Abdelfattah M; Omran, Mohamed M; Attallah, Ahmed A; Abdelrazek, Mohamed A; Farid, Khaled; El-Dosoky, Ibrahim
2017-04-01
Small-sized HCC can be effectively cured by surgery with good clinical outcomes. A highly sensitive HCC α-fetoprotein routine test (HCC-ART) for HCC diagnosis as well as a simplied form of the HCC-ART were reported in the British Journal of Cancer. Here, we verified and studied the applicability of the HCC-ART to the detection of early-stage HCC. 341 cirrhotic patients and 318 HCC patients were included in this study. For each, the HCC-ART score was calculated, and then the sensitivity, specificity, and results of an ROC curve analysis were compared between the HCC-ART and AFP when these biomarkers were used to detect small-sized HCC. Different HCC-ART cutoffs were set for the detection of different tumor sizes. The HCC-ART (AUC = 0.871, 70% sensitivity, 97% specificity) and the simplified HCC-ART (AUC = 0.934, 82% sensitivity, 100% specificity) were found to have high predictive power when attempting to separate cirrhotic patients from those with small-sized HCC. The simplified HCC-ART score was superior to AFP for determining stages according to the early Okuda (0.950 AUC, 84% sensitivity, 99% specificity), CLIP (0.945 AUC, 84% sensitivity, 99% specificity), and BCLC (1.000 AUC, 100% sensitivity, 99% specificity) staging systems. The simplified HCC-ART score was more strongly correlated than AFP and other staging systems with HCC tumor size (P < 0.0001; r = 0.8). The HCC-ART is superior to AFP for diagnosing early-stage HCC. Due to its advantages of minimal variability and a wide continuous scale for assessing HCC severity, the simplified HCC-ART has the potential to be more widely used than the original HCC-ART.
Girman, Cynthia J; Faries, Douglas; Ryan, Patrick; Rotelli, Matt; Belger, Mark; Binkowitz, Bruce; O'Neill, Robert
2014-05-01
The use of healthcare databases for comparative effectiveness research (CER) is increasing exponentially despite its challenges. Researchers must understand their data source and whether outcomes, exposures and confounding factors are captured sufficiently to address the research question. They must also assess whether bias and confounding can be adequately minimized. Many study design characteristics may impact on the results; however, minimal if any sensitivity analyses are typically conducted, and those performed are post hoc. We propose pre-study steps for CER feasibility assessment and to identify sensitivity analyses that might be most important to pre-specify to help ensure that CER produces valid interpretable results.
Smith, Toby O; Drew, Benjamin T; Toms, Andoni P; Donell, Simon T; Hing, Caroline B
2012-12-01
To assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and computed tomography arthrography (CTA) for the detection of chondral lesions of the patellofemoral and tibiofemoral joints. A review of published and unpublished literature sources was conducted on 22nd September 2011. All studies assessing the diagnostic test accuracy (sensitivity/specificity) of MRI or MRA or CTA for the assessment of adults with chondral (cartilage) lesions of the knee (tibiofemoral/patellofemoral joints) with surgical comparison (arthroscopic or open) as the reference test were included. Data were analysed through meta-analysis. Twenty-seven studies assessing 2,592 knees from 2,509 patients were included. The findings indicated that whilst presenting a high specificity (0.95-0.99), the sensitivity of MRA, MRI and CTA ranged from 0.70 to 0.80. MRA was superior to MRI and CTA for the detection of patellofemoral joint chondral lesions and that higher field-strength MRI scanner and grade four lesions were more accurately detected compared with lower field-strength and grade one lesions. There appeared no substantial difference in diagnostic accuracy between the interpretation from musculoskeletal and general radiologists when undertaking an MRI review of tibiofemoral and patellofemoral chondral lesions. Specialist radiological imaging is specific for cartilage disease in the knee but has poorer sensitivity to determine the therapeutic options in this population. Due to this limitation, there remains little indication to replace the 'gold-standard' arthroscopic investigation with MRI, MRA or CTA for the assessment of adults with chondral lesions of the knee. II.
Swenson, David W; Pietryga, Jason A; Grand, David J; Chang, Kevin J; Murphy, Brian L; Egglin, Thomas K
2014-07-01
The purpose of this study was to compare the diagnostic performance of four radiographic signs of gastric band slippage: abnormal phi angle, the "O sign," inferior displacement of the superolateral gastric band margin, and presence of an air-fluid level above the gastric band. A search of the electronic medical record identified 21 patients with a surgically proven slipped gastric band and 63 randomly-selected asymptomatic gastric band patients who had undergone barium swallow studies. These studies were evaluated for the four signs of band slippage by two independent radiologists who were blinded to clinical data. Sensitivity, specificity, and positive and negative predictive values were calculated for each radiographic sign of band slippage. Interobserver agreement between radiologists was assessed using the Fleiss kappa statistic. In evaluating for gastric band slippage, an abnormal phi angle greater than 58° was 91-95% sensitive and 52-62% specific (κ = 0.78), the O sign was 33-48% sensitive but 97% specific (κ = 0.84), inferior displacement of the superolateral band margin by more than 2.4 cm from the diaphragm was 95% sensitive and 97-98% specific (κ = 0.97), and the presence of an air-fluid level was 95% sensitive and 100% specific (κ = 1.00). We report two previously undescribed radiographic signs of gastric band slippage that are both sensitive and specific for this important surgical complication and recommend that these signs should be incorporated into the imaging evaluation of gastric band patients.
Goodband, Emily L; Serrano, Gonçalo; Constantino-Casas, Fernando; Archer, Joy; Watson, Penny J; Williams, Tim L
2018-01-01
The objectives of this study were fourfold: technical validation of a commercial canine 1,2-o-dilauryl-rac-glycero glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay, to calculate a reference interval for DGGR lipase by the indirect a posteriori method, to establish biological validity of the assay, and to assess agreement between DGGR lipase and specific canine pancreatic lipase (Spec cPL) assays. Dogs with histologically confirmed acute pancreatitis (n=3), chronic pancreatitis (n=8) and normal pancreatic tissue (n=7) with stored (-80°C) serum samples were identified. Relevant controls were selected. Precision, reproducibility and linearity of DGGR lipase, and the effect of sample haemolysis and freezing, were assessed. Sensitivity and specificity of DGGR lipase and Spec cPL were determined. Agreement between these two parameters was calculated using Cohen's kappa coefficient (κ). The DGGR lipase assay demonstrated excellent precision, reproducibility and linearity. Sample haemolysis and storage at -80°C for 12 months did not influence the assay. DGGR lipase (>245IU/l) and Spec cPL (>400µg/l) both showed poor sensitivity but excellent specificity for acute pancreatitis, and poor to moderate sensitivity but excellent specificity for chronic pancreatitis. Substantial agreement (κ=0.679) was found between DGGR lipase and Spec cPL. The validated DGGR lipase assay had similar sensitivity and specificity for the diagnosis of acute and chronic pancreatitis to Spec cPL. DGGR lipase is a reliable alternative to Spec cPL for the diagnosis of pancreatitis.
Hontoir, Fanny; Nisolle, Jean-François; Meurisse, Hubert; Simon, Vincent; Tallier, Max; Vanderstricht, Renaud; Antoine, Nadine; Piret, Joëlle; Clegg, Peter; Vandeweerd, Jean-Michel
2014-01-01
Articular cartilage defects are prevalent in metacarpo/metatarsophalangeal (MCP/MTP) joints of horses. The aim of this study was to determine and compare the sensitivity and specificity of 3-Tesla magnetic resonance imaging (3-T MRI) and computed tomography arthrography (CTA) to identify structural cartilage defects in the equine MCP/MTP joint. Forty distal cadaver limbs were imaged by CTA (after injection of contrast medium) and by 3-T MRI using specific sequences, namely, dual-echo in the steady-state (DESS), and sampling perfection with application-optimised contrast using different flip-angle evolutions (SPACE). Gross anatomy was used as the gold standard to evaluate sensitivity and specificity of both imaging techniques. CTA sensitivity and specificity were 0.82 and 0.96, respectively, and were significantly higher than those of MRI (0.41 and 0.93, respectively) in detecting overall cartilage defects (no defect vs. defect). The intra and inter-rater agreements were 0.96 and 0.92, respectively, and 0.82 and 0.88, respectively, for CT and MRI. The positive predictive value for MRI was low (0.57). CTA was considered a valuable tool for assessing cartilage defects in the MCP/MTP joint due to its short acquisition time, its specificity and sensitivity, and it was also more accurate than MRI. However, MRI permits assessment of soft tissues and subchondral bone and is a useful technique for joint evaluation, although clinicians should be aware of the limitations of this diagnostic technique, including reduced accuracy. Copyright © 2013 Elsevier Ltd. All rights reserved.
Berger, Rachel P; Parks, Sharyn; Fromkin, Janet; Rubin, Pamela; Pecora, Peter J
2015-04-01
To assess the accuracy of an International Classification of Diseases (ICD) code-based operational case definition for abusive head trauma (AHT). Subjects were children <5 years of age evaluated for AHT by a hospital-based Child Protection Team (CPT) at a tertiary care paediatric hospital with a completely electronic medical record (EMR) system. Subjects were designated as non-AHT traumatic brain injury (TBI) or AHT based on whether the CPT determined that the injuries were due to AHT. The sensitivity and specificity of the ICD-based definition were calculated. There were 223 children evaluated for AHT: 117 AHT and 106 non-AHT TBI. The sensitivity and specificity of the ICD-based operational case definition were 92% (95% CI 85.8 to 96.2) and 96% (95% CI 92.3 to 99.7), respectively. All errors in sensitivity and three of the four specificity errors were due to coder error; one specificity error was a physician error. In a paediatric tertiary care hospital with an EMR system, the accuracy of an ICD-based case definition for AHT was high. Additional studies are needed to assess the accuracy of this definition in all types of hospitals in which children with AHT are cared for. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Kawakami, Ryoko; Miyachi, Motohiko
2010-10-01
This study aimed to determine the validity of a standard questionnaire to assess amount of physical activity (PA) and cardiorespiratory fitness (VO2peak). A total of 483 men and women, aged 20 to 69 years, participated. The standard questionnaire included 3 items about exercise, PA, and walking speed. All questions were designed to require an answer of Yes or No. Subjects were classified into one of four groups regarding the number of Yes answers to the three questions, giving activity levels of 0 to 3. The amount of PA was measured objectively with a tn-axial accelerometer which could also calculate daily step counts, and the amounts of PA under 3 metabolic equivalents (METs) and at 3 METs or more. VO2peak. was measured by incremental cycle exercise tests with indirect calorimetry. The daily step counts, the amount of PA at 3 METs or more, and the VO2peak. were significantly higher in subjects who answered Yes to each question than in those who answered No. Sensitivity and specificity of each question were 62-73% and 45-71% for the amount of PA established with the "Exercise and Physical Activity Reference for Health Promotion 2006 (EPAR2006)". The sum of sensitivity and specificity was the highest when the cutoff value was activity level 2 (sensitivity 73%, specificity 68%). Sensitivity and specificity for VO2max established by EPAR2006 were lower than those for the amount of PA. These results suggest that only answering simple questions with a standard questionnaire is sufficient for estimation of PA levels for specific medical checkups and health guidance, even though the accuracy is somewhat limited.
[Diagnostic value of cardiac magnetic resonance in patients with acute viral myocarditis].
Ouyang, Haichun; Chen, Haixiong; Hu, Yunzhao; Wu, Yanxian; Li, Wensheng; Chen, Yuying; Cen, Yujian
2014-11-01
To assess the diagnostic value of cardiac magnetic resonance (CMR) in patients with acute viral myocarditis. Thirty patients with suspected acute viral myocarditis admitted in first people's hospital of Shunde from June 2011 to June 2013 were included in this prospective study. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of acute viral myocarditis were evaluated by clinical diagnosis. Diagnostic value among different scan methods and Lake Louise criteria were compared. Acute viral myocarditis was diagnosed in 63.33% (19/30) patients.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 57.89%, 72.73%, 78.57%, 50.00%, 63.33%, respectively by edema imaging (ER).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 63.64%, 78.95%, 63.64%, 73.33%, respectively using global relative enhancement (gRE).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 54.55%, 75.00%, 60.00%, 70.00%, respectively using late gadolinium enhancement (LGE) criteria.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 84.21%, 81.82%, 88.89%, 75.00%, 83.33% using Lake Louise criteria. The sensitivity, specificity, PPV, NPV, and diagnostic accuracy using Lake Louise criteria were significantly higher than using ER, gRE, LGE alone(all P < 0.05).Specificity was higher using ER than using gRE and LGE (both P < 0.05). The sensitivity, NPV, and diagnostic accuracy were significantly higher using gRE than using ER (all P < 0.05) and was similar as using LGE (all P > 0.05). Cardiac magnetic resonance is an excellent imaging modality for the diagnosis of acute viral myocarditis.
Buelens-Sleumer, Laura S.; Cox, Linda; den Hartog, Marcel; de Jong, Niels; Teshima, Reiko; Garssen, Johan; Boon, Louis; Knippels, Léon M. J.
2014-01-01
Background Cow’s milk-derived whey hydrolysates are nutritional substitutes for allergic infants. Safety or residual allergenicity assessment of these whey hydrolysates is crucial. Currently, rat basophilic leukemia RBL-2H3 cells expressing the human IgE receptor α-chain (huFcεRIα-RBL-2H3), sensitized with serum IgE from cow’s milk allergic children, are being employed to assess in vitro residual allergenicity of these whey hydrolysates. However, limited availability and inter-lot variation of these allergic sera impede standardization of whey hydrolysate safety testing in degranulation assays. Objective An oligoclonal pool of chimeric human (chu)IgE antibodies against bovine β-lactoglobulin (a major allergen in whey) was generated to increase sensitivity, specificity, and reproducibility of existing degranulation assays. Methods Mice were immunized with bovine β-lactoglobulin, and subsequently the variable domains of dissimilar anti-β-lactoglobulin mouse IgG antibodies were cloned and sequenced. Six chimeric antibodies were generated comprising mouse variable domains and human constant IgE/κ domains. Results After sensitization with this pool of anti-β-lactoglobulin chuIgEs, huFcεRIα-expressing RBL-2H3 cells demonstrated degranulation upon cross-linking with whey, native 18 kDa β-lactoglobulin, and 5–10 kDa whey hydrolysates, whereas a 3 kDa whey hydrolysate and cow’s milk powder (mainly casein) showed no degranulation. In parallel, allergic serum IgEs were less sensitive. In addition, our pool anti-β-lactoglobulin chuIgEs recognized multiple allergenic immunodominant regions on β-lactoglobulin, which were also recognized by serum IgEs from cow’s milk allergic children. Conclusion Usage of our ‘unlimited’ source and well-defined pool of β-lactoglobulin-specific recombinant chuIgEs to sensitize huFcεRIα on RBL-2H3 cells showed to be a relevant and sensitive alternative for serum IgEs from cow’s milk allergic patients to assess safety of whey-based non-allergic hydrolyzed formula. PMID:25153680
Guzman, Maria G.; Jaenisch, Thomas; Gaczkowski, Roger; Ty Hang, Vo Thi; Sekaran, Shamala Devi; Kroeger, Axel; Vazquez, Susana; Ruiz, Didye; Martinez, Eric; Mercado, Juan C.; Balmaseda, Angel; Harris, Eva; Dimano, Efren; Leano, Prisca Susan A.; Yoksan, Sutee; Villegas, Elci; Benduzu, Herminia; Villalobos, Iris; Farrar, Jeremy; Simmons, Cameron P.
2010-01-01
Background Early diagnosis of dengue can assist patient triage and management and prevent unnecessary treatments and interventions. Commercially available assays that detect the dengue virus protein NS1 in the plasma/serum of patients offers the possibility of early and rapid diagnosis. Methodology/Principal Findings The sensitivity and specificity of the Pan-E Dengue Early ELISA and the Platelia™ Dengue NS1 Ag assays were compared against a reference diagnosis in 1385 patients in 6 countries in Asia and the Americas. Platelia was more sensitive (66%) than Pan-E (52%) in confirmed dengue cases. Sensitivity varied by geographic region, with both assays generally being more sensitive in patients from SE Asia than the Americas. Both kits were more sensitive for specimens collected within the first few days of illness onset relative to later time points. Pan-E and Platelia were both 100% specific in febrile patients without evidence of acute dengue. In patients with other confirmed diagnoses and healthy blood donors, Platelia was more specific (100%) than Pan-E (90%). For Platelia, when either the NS1 test or the IgM test on the acute sample was positive, the sensitivity versus the reference result was 82% in samples collected in the first four days of fever. NS1 sensitivity was not associated to disease severity (DF or DHF) in the Platelia test, whereas a trend for higher sensitivity in DHF cases was seen in the Pan-E test (however combined with lower overall sensitivity). Conclusions/Significance Collectively, this multi-country study suggests that the best performing NS1 assay (Platelia) had moderate sensitivity (median 64%, range 34–76%) and high specificity (100%) for the diagnosis of dengue. The poor sensitivity of the evaluated assays in some geographical regions suggests further assessments are needed. The combination of NS1 and IgM detection in samples collected in the first few days of fever increased the overall dengue diagnostic sensitivity. PMID:20824173
Wiebking, Ulrich; Pacha, Tarek Omar; Jagodzinski, Michael
2015-03-01
Ankle sprain injuries, often due to lateral ligamentous injury, are the most common sports traumatology conditions. Correct diagnoses require an understanding of the assessment tools with a high degree of diagnostic accuracy. Obviously, there are still no clear consensuses or standard methods to differentiate between a ligament tear and an ankle sprain. In addition to clinical assessments, stress sonography, arthrometer and other methods are often performed simultaneously. These methods are often costly, however, and their accuracy is controversial. The aim of this study was to investigate three different measurement tools that can be used after a lateral ligament lesion of the ankle with injury of the anterior talofibular ligament to determine their diagnostic accuracy. Thirty patients were recruited for this study. The mean patient age was 35±14 years. There were 15 patients with a ligamentous rupture and 15 patients with an ankle sprain. We quantified two devices and one clinical assessment by which we calculated the sensitivity and specifity: Stress sonography according to Hoffmann, an arthrometer to investigate the 100N talar drawer and maximum manual testing and the clinical assessment of the anterior drawer test. A high resolution sonography was used as the gold standard. The ultrasound-assisted gadgetry according to Hoffmann, with a 3mm cut-off value, displayed a sensitivity of 0.27 and a specificity of 0.87. Using a 3.95mm cut-off value, the arthrometer displayed a sensitivity of 0.8 and a specificity of 0.4. The clinical investigation sensitivities and specificities were 0.93 and 0.67, respectively. Different assessment methods for ankle rupture diagnoses are suggested in the literature; however, these methods lack reliable data to set investigation standards. Clinical examination under adequate analgesia seems to remains the most reliable tool to investigate ligamentous ankle lesions. Further clinical studies with higher case numbers are necessary, however, to evaluate these findings and to measure the reliability. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
van Leth, Frank; den Heijer, Casper; Beerepoot, Mariëlle; Stobberingh, Ellen; Geerlings, Suzanne; Schultsz, Constance
2017-04-01
Increasing antimicrobial resistance (AMR) requires rapid surveillance tools, such as Lot Quality Assurance Sampling (LQAS). LQAS classifies AMR as high or low based on set parameters. We compared classifications with the underlying true AMR prevalence using data on 1335 Escherichia coli isolates from surveys of community-acquired urinary tract infection in women, by assessing operating curves, sensitivity and specificity. Sensitivity and specificity of any set of LQAS parameters was above 99% and between 79 and 90%, respectively. Operating curves showed high concordance of the LQAS classification with true AMR prevalence estimates. LQAS-based AMR surveillance is a feasible approach that provides timely and locally relevant estimates, and the necessary information to formulate and evaluate guidelines for empirical treatment.
George, Ajesh; Dahlen, Hannah G; Blinkhorn, Anthony; Ajwani, Shilpi; Bhole, Sameer; Ellis, Sharon; Yeo, Anthony; Elcombe, Emma; Sadozai, Ayesha; Johnson, Maree
2016-11-09
Midwives can play a key role in promoting the oral health of pregnant women and assessing their oral health status. A maternal oral assessment tool (MOS) was developed and pilot tested by the study investigators to assist midwives in this role and the results were promising. The aim of this study was to undertake further sensitivity and specificity assessment of the MOS tool using two-comparison approaches- the longer oral health screening tool known as the Oral Health Impact Profile (OHIP-14) and an oral assessment by trained study dentists. Pregnant women were recruited for this study as part of a larger randomised controlled trial of a Midwifery Initiated Oral Health (MIOH) program. Pregnant women completed the MOS and OHIP-14 as part of their initial assessment undertaken by 38 trained and accredited midwives. A dental assessment was conducted for all women in the intervention group using three trained study dentists with high inter rater reliability. Two hundred and eleven pregnant women participated in the validation of the MOS tool. Results from both approaches found the MOS tool to have high sensitivity, correctly identifying 88-94 % of women at risk of poor dental health, and low specificity (14-21 %). This study has shown that the MOS tool can be successfully implemented by midwives during a woman's first antenatal visit and can identify up to 94 % of women at risk of poor oral health and needing a dental referral. The tool has the potential to be transferable to other antenatal care providers and could be incorporated into hospital obstetric database systems. ACTRN12612001271897 , 6 th Dec 2012, retrospectively registered.
Biological validation of self-reported condom use among sex workers in Guinea.
Aho, Joséphine; Koushik, Anita; Diakité, Soumaïla Laye; Loua, Kovana Marcel; Nguyen, Vinh-Kim; Rashed, Sélim
2010-12-01
Self-reported condom use may be prone to social desirability bias. Our aim was to assess the validity of self-reported condom use in a population of female sex workers using prostate specific antigen (PSA) as a gold standard biomarker of recent unprotected vaginal intercourse. We collected data on 223 sex-workers in Conakry, Guinea in order to assess the sensitivity and specificity of self-reported condom use as well as to examine the predictors of discordance between self-report and PSA presence. PSA was detected in 38.4% of samples. Sensitivity of self-reported condom use was 14.6% and its specificity was 94.7%. Self-perceived high risk of HIV infection was the only significant independent predictor of misreported condom use. PSA could be useful to validate self-reported condom use in surveys and to allow a better understanding of factors associated with social desirability in sexual behaviour reporting.
Chan, B H; Leung, Y Y
2018-04-01
The comparison of serial radiographs and clinical photographs is considered the current accepted standard for the diagnosis of active condylar hyperplasia in patients with facial asymmetry. Single photon emission computed tomography (SPECT) has recently been proposed as an alternative method. SPECT can be interpreted using three reported methods absolute difference in uptake, uptake ratio, and relative uptake. SPECT findings were compared to those from serial comparisons of radiographs and clinical photographs taken at the time of SPECT and a year later; the sensitivities and specificities were determined. Two hundred patient scans were evaluated. Thirty-four patients showed active growth on serial growth assessment. On comparison with serial growth assessment, the sensitivity and specificity of the three methods ranged between 32.4% and 67.6%, and 36.1% and 78.3%, respectively. Analysis using receiver operating characteristic (ROC) curves revealed area under the curve (AUC) values of <0.58. The average age (mean±standard deviation) of patients with active growth was 18.6±2.8 years, and average growth in the anteroposterior, vertical, and transverse directions was 0.94±0.91mm, 0.88±0.86mm, and 1.4±0.66 mm, respectively. With such low sensitivity and specificity values, it is not justifiable to use SPECT in place of serial growth assessment for the determination of condylar growth status. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Mobarak, Lamiaa; Nabeel, Mohammed M.; Hassan, Ehsan; Omran, Dalia; Zakaria, Zeinab
2016-01-01
Background Hepatitis C virus is a worldwide problem. Noninvasive methods for liver fibrosis assessment as ultrasound-based approaches have emerged to replace liver biopsy. The aim of this study was to evaluate the diagnostic accuracy of real-time elastography (RTE) in the assessment of liver fibrosis in patients with chronic hepatitis C (CHC), compared with transient elastography and liver biopsy. Methods RTE, FibroScan and liver biopsy were performed in 50 CHC patients. In addition, aspartate aminotransferase to platelet ratio index (APRI) and routine laboratory values were included in the analysis. Results RTE was able to diagnose significant hepatic fibrosis (F ≥2) according to METAVIR scoring system at cut-off value of 2.49 with sensitivity 100%, specificity 66%, and area under the receiver-operating characteristics (AUROC) 0.8. FibroScan was able to predict significant fibrosis at cut-off value 7.5 KPa with sensitivity 88%, specificity 100%, and AUROC 0.94.APRI was able to predict significant hepatic fibrosis (F ≥2) with sensitivity 54%, specificity 80%, and AUROC 0.69. There was a significant positive correlation between the FibroScan score and RTE score (r=0.6, P=0.001). Conclusions Although FibroScan is superior in determining significant hepatic fibrosis, our data suggest that RTE may be a useful and promising noninvasive method for liver fibrosis assessment in CHC patients especially in cases with technical limitations for FibroScan. PMID:27366038
Mobarak, Lamiaa; Nabeel, Mohammed M; Hassan, Ehsan; Omran, Dalia; Zakaria, Zeinab
2016-01-01
Hepatitis C virus is a worldwide problem. Noninvasive methods for liver fibrosis assessment as ultrasound-based approaches have emerged to replace liver biopsy. The aim of this study was to evaluate the diagnostic accuracy of real-time elastography (RTE) in the assessment of liver fibrosis in patients with chronic hepatitis C (CHC), compared with transient elastography and liver biopsy. RTE, FibroScan and liver biopsy were performed in 50 CHC patients. In addition, aspartate aminotransferase to platelet ratio index (APRI) and routine laboratory values were included in the analysis. RTE was able to diagnose significant hepatic fibrosis (F ≥2) according to METAVIR scoring system at cut-off value of 2.49 with sensitivity 100%, specificity 66%, and area under the receiver-operating characteristics (AUROC) 0.8. FibroScan was able to predict significant fibrosis at cut-off value 7.5 KPa with sensitivity 88%, specificity 100%, and AUROC 0.94.APRI was able to predict significant hepatic fibrosis (F ≥2) with sensitivity 54%, specificity 80%, and AUROC 0.69. There was a significant positive correlation between the FibroScan score and RTE score (r=0.6, P=0.001). Although FibroScan is superior in determining significant hepatic fibrosis, our data suggest that RTE may be a useful and promising noninvasive method for liver fibrosis assessment in CHC patients especially in cases with technical limitations for FibroScan.
Humphries, Thomas; Singh, Rajiv
2018-01-01
Olfactory disturbance (OD) is common after traumatic brain injury (TBI). Screening for OD can be performed by several different methods. While odour identification tools are considered more accurate, they are time consuming. The predominant method in clinical practice remains the use of a single odour. This study aimed to compare a brief single-odour identification tool (BSOIT) with a more detailed 12-odour assessment tool. One hundred seventy consecutive patients with TBI had their olfaction assessed using BSOIT and a 12-item tool at a single time point. The sensitivity and specificity of the BSOIT were calculated. The sensitivity and specificity of the BSOIT as compared to the Burghart tool were 57.5% and 100%, respectively, for all ODs (anosmia and hyposmia). The sensitivity and specificity for anosmia only were 93.5% and 96.7%, respectively. For the two tools, the Cohen's kappa coefficient showed moderate agreement when both anosmia and hyposmia were considered (k = 0.619, p < 0.001) but a very strong agreement when only anosmia was considered (k = 0.844, p < 0.001). For both the tools, anosmia had a significant association with TBI severity (p < 0.001). However, hyposmia showed no such association. The BSOIT is very effective at identifying anosmia but not hyposmia, producing comparable results to a more detailed test. It can be effective in clinical practice and takes considerably less time.
Mausbach, Brent T.; Bowie, Christopher R.; Harvey, Philip D.; Twamley, Elizabeth W.; Goldman, Sherrill R.; Jeste, Dilip V.; Patterson, Thomas L.
2009-01-01
The objective of this study was to examine the sensitivity and specificity of a performance-based measure of functional capacity, the UCSD Performance-Based Skills Assessment (UPSA) for the prediction of independent living status in patients with chronic schizophrenia-related conditions. A sample of 434 adults with schizophrenia or schizoaffective disorder was administered the UPSA and assessed for independent living status. Participants were classified as “independent” if they were living alone in an apartment, house, or single-resident occupancy (e.g., hotel room) and non-independent if they resided in a care facility (e.g., Board-and-Care home, Skilled Nursing Facility). Receiver Operator Characteristic (ROC) curves were calculated with the UPSA and Mattis’ Dementia Rating Scale (DRS) scores as predictor variables and residential independence as the state variable. Of the 434 participants, 99 (23%) were living independently at the time of assessment. The discriminant validity of the UPSA was adequate (ROC area under the curve = 0.74; 95% CI: 0.68–0.79), with greatest dichotomization for the UPSA at a cutoff score of 75 (68% accuracy, 69% sensitivity, 66% specificity), or 80 (68% accuracy, 59% sensitivity, 76% specificity). The UPSA was also a significantly better predictor of living status than was the DRS, based on ROC (z = 2.43, p = .015). The UPSA is a brief measure of functional capacity that predicts the ability of patients with schizophrenia to reside independently in the community. PMID:17303168
West, Caroline; Ploth, David; Fonner, Virginia; Mbwambo, Jessie; Fredrick, Francis; Sweat, Michael
2016-04-01
Noncommunicable diseases are on pace to outnumber infectious disease as the leading cause of death in sub-Saharan Africa, yet many questions remain unanswered with concern toward effective methods of screening for type II diabetes mellitus (DM) in this resource-limited setting. We aim to design a screening algorithm for type II DM that optimizes sensitivity and specificity of identifying individuals with undiagnosed DM, as well as affordability to health systems and individuals. Baseline demographic and clinical data, including hemoglobin A1c (HbA1c), were collected from 713 participants using probability sampling of the general population. We used these data, along with model parameters obtained from the literature, to mathematically model 8 purposed DM screening algorithms, while optimizing the sensitivity and specificity using Monte Carlo and Latin Hypercube simulation. An algorithm that combines risk assessment and measurement of fasting blood glucose was found to be superior for the most resource-limited settings (sensitivity 68%, sensitivity 99% and cost per patient having DM identified as $2.94). Incorporating HbA1c testing improves the sensitivity to 75.62%, but raises the cost per DM case identified to $6.04. The preferred algorithms are heavily biased to diagnose those with more severe cases of DM. Using basic risk assessment tools and fasting blood sugar testing in lieu of HbA1c testing in resource-limited settings could allow for significantly more feasible DM screening programs with reasonable sensitivity and specificity. Copyright © 2016 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Sensitivity of Hyperdense Basilar Artery Sign on Non-Enhanced Computed Tomography.
Ernst, Marielle; Romero, Javier M; Buhk, Jan-Hendrik; Cheng, Bastian; Herrmann, Jochen; Fiehler, Jens; Groth, Michael
2015-01-01
The hyperdense basilar artery sign (HBAS) is an indicator of vessel occlusion on non contrast-enhanced computer tomography (NECT) in acute stroke patients. Since basilar artery occlusion (BAO) is associated with a high mortality and morbidity, its early detection is of great clinical value. We sought to analyze the influence of density measurement as well as a normalized ratio of Hounsfield unit/hematocrit (HU/Hct) ratio on the detection of BAO on NECT in patients with suspected BAO. 102 patients with clinically suspected BAO were examined with NECT followed immediately by Multidetector computed tomography Angiography. Two observers independently analyzed the images regarding the presence or absence of HBAS on NECT and performed HU measurements in the basilar artery. Receiver operating characteristic curve analysis was performed to determine the optimal density threshold for BAO using attenuation measurements or HU/Hct ratio. Sensitivity of visual detection of the HBAS on NECT was relatively low 81% (95%-CI, 54-95%) while specificity was high 91% (95%-CI, 82-96%). The highest sensitivity was achieved by the combination of visual assessment and additional quantitative attenuation measurements applying a cut-off value of 46.5 HU with 94% sensitivity and 81% specificity for BAO. A HU/Hct ratio >1.32 revealed sensitivity of 88% (95%-CI, 60-98%) and specificity of 84% (95%-CI, 74-90%). In patients with clinically suspected acute BAO the combination of visual assessment and additional attenuation measurement with a cut-off value of 46.5 HU is a reliable approach with high sensitivity in the detection of BAO on NECT.
Impaired temporal contrast sensitivity in dyslexics is specific to retain-and-compare paradigms.
Ben-Yehudah, G; Sackett, E; Malchi-Ginzberg, L; Ahissar, M
2001-07-01
Developmental dyslexia is a specific reading disability that affects 5-10% of the population. Recent studies have suggested that dyslexics may experience a deficit in the visual magnocellular pathway. The most extensively studied prediction deriving from this hypothesis is impaired contrast sensitivity to transient, low-luminance stimuli at low spatial frequencies. However, the findings are inconsistent across studies and even seemingly contradictory. In the present study, we administered several different paradigms for assessing temporal contrast sensitivity, and found both impaired and normal contrast sensitivity within the same group of dyslexic participants. Under sequential presentation, in a temporal forced choice paradigm, dyslexics showed impaired sensitivity to both drifting and flickering gratings. However, under simultaneous presentation, with a spatial forced choice paradigm, dyslexics' sensitivity did not differ from that of the controls. Within each paradigm, dyslexics' sensitivity was poorer at higher temporal frequencies, consistent with the magnocellular hypothesis. These results suggest that a basic perceptual impairment in dyslexics may be their limited ability to retain-and-compare perceptual traces across brief intervals.
Cabañas, R; Calderón, O; Ramírez, E; Fiandor, A; Caballero, T; Heredia, R; Herranz, P; Madero, R; Quirce, S; Bellón, T
2018-03-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a severe delayed hypersensitivity reaction. The determination of drug causality is complex. The lymphocyte transformation test (LTT) has been reported positive in more than 50% of DRESS cases. Nevertheless, the sensitivity and specificity of LTT specifically in DRESS have not yet been established. Rechallenge with the culprit drug is contraindicated and cannot be used as gold standard for sensitivity and specificity determination. To estimate the sensitivity and specificity of LTT in a clinically defined series of patients with DRESS. Some 41 patients diagnosed with DRESS were included in the study. The results of the algorithm of the Spanish Pharmacovigilance System were used as the standard for a correct diagnosis of drug causality. A standard LTT was performed with involved drugs in acute or recovery samples. A stimulation index (SI) ≥2 in at least one concentration except for beta-lactams (SI ≥3) and contrast media (SI ≥4) was considered positive. Contingency tables and ROC curves were used for analysis. Sensitivity and specificity of LTT in the recovery phase of DRESS were 73% and 82%, respectively, whereas in the acute phase, they were only 40% and 30%, respectively. Comparison of skin tests and LTT confirmed a higher sensitivity and specificity of LTT in DRESS. LTT showed high sensitivity (S) and specificity (Sp) for anticonvulsants (S 100%, Sp 100%; P = .008), anti-TB drugs (S 87.5%, Sp 100%; P = .004), and beta-lactams (S 73%, Sp 100%; P = .001). ROC curves revealed that the best criteria for LTT positivity for all drugs are SI ≥2 in at least one concentration, increasing overall sensitivity to 80%, and for beta-lactams from 73% to 92%. LTT is a good diagnostic tool for drug causality in DRESS, mainly when performed in the recovery phase. © 2017 John Wiley & Sons Ltd.
Vázquez, Gustavo Héctor; Romero, Ester; Fabregues, Fernando; Pies, Ronald; Ghaemi, Nassir; Mota-Castillo, Manuel
2010-01-01
Bipolar disorder is commonly misdiagnosed, perhaps more so in Latin American and Spanish-speaking populations than in the United States. The Bipolar Spectrum Diagnostic Scale (BSDS) is a 19-item screening instrument designed to assist in screening for all types of bipolar disorder. The authors investigated the sensitivity of a Spanish-language version of the BSDS in a cohort of 65 outpatients with a diagnosis of bipolar disorder, based on a semi-structured interview and Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision criteria. To determine specificity, we assessed a control group of 36 outpatients with diagnosis of unipolar major depressive disorder. The overall sensitivity of the BSDS Spanish version with bipolar disorders types I, II, and NOS was 0.70, which was slightly lower than the sensitivity in the study using the English version of the BSDS (0.76). The specificity was 0.89. When the threshold was decreased from 13 to 12, the sensitivity of the Spanish BSDS increased to 0.76 and specificity dropped to 0.81. The Spanish version of the BSDS is promising as a screening instrument in Spanish-speaking populations. Copyright 2010 Elsevier Inc. All rights reserved.
Berry, Carolyn A; Quinn, Kelly; Wolf, Raoul; Mosnaim, Giselle; Shalowitz, Madeleine
2005-07-01
The health and health care needs of non-English-speaking Hispanic families with children are poorly understood, in part because they are often excluded from research owing to language barriers. Instruments that are valid in English and Spanish are necessary to accurately evaluate the magnitude of asthma prevalence and morbidity among Hispanics. To establish the sensitivity and specificity of the English and Spanish versions of the asthma portion of the Brief Pediatric Asthma Screen Plus (BPAS+) in a low-income Hispanic population. The validation sample consisted of 145 children whose parents completed the BPAS+ in Spanish and 78 whose parents completed it in English. Bilingual clinicians conducted the examinations on which the clinical assessments were based. We compared the BPAS+ results with the clinical assessment findings to determine the sensitivity and specificity of the BPAS + among Hispanics in terms of identifying children who warrant further medical evaluation for asthma. The sensitivity and specificity of the asthma portion of the Spanish BPAS+ were 74% and 86%, respectively. The sensitivity and specificity of the asthma portion of the English BPAS+ were 61% and 83%, respectively. The asthma portion of the BPAS+, a valid screen for identifying children who are in need of further evaluation for potentially undiagnosed asthma, is valid for low-income Hispanics in Spanish and English. As the Hispanic population continues to grow, it is imperative that researchers have English and Spanish instruments that are valid for this population.
Recurrent rotator cuff tear: is ultrasound imaging reliable?
Gilat, Ron; Atoun, Ehud; Cohen, Ornit; Tsvieli, Oren; Rath, Ehud; Lakstein, Dror; Levy, Ofer
2018-02-02
The diagnostic workup of the painful shoulder after rotator cuff repair (RCR) can be quite challenging. The aim of this study was to assess the reliability of ultrasonography (US) for the detection of recurrent rotator cuff tears in patients with shoulder pain after RCR. We hypothesized that US for the diagnosis of recurrent rotator cuff tear after RCR would not prove to be reliable when compared with surgical arthroscopic confirmation (gold standard). In this cohort study (diagnosis), we retrospectively analyzed the data of 39 patients with shoulder pain after arthroscopic RCR who had subsequently undergone US, followed by revision arthroscopy. The rotator cuff was evaluated first using US for the presence of retears. Thereafter, revision arthroscopy was performed, and the diagnosis was either established or disproved. The sensitivity and specificity of US were assessed in reference to revision arthroscopy (gold standard). A rotator cuff retear was indicated by US in 21 patients (54%) and by revision arthroscopy in 26 patients (67%). US showed a sensitivity of 80.8% and specificity of 100% in the diagnosis of rotator cuff retears. Omission of partial rotator cuff retears resulted in a spike in sensitivity to 94.7%, with 100% specificity remaining. US imaging is a highly sensitive and specific test for the detection of recurrent rotator cuff tears, as confirmed by revision arthroscopy, in patients with a painful shoulder after primary RCR. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
The prevalence of depression and the accuracy of depression screening tools in migraine patients.
Amoozegar, Farnaz; Patten, Scott B; Becker, Werner J; Bulloch, Andrew G M; Fiest, Kirsten M; Davenport, W Jeptha; Carroll, Christopher R; Jette, Nathalie
2017-09-01
Migraine and depression are common comorbid conditions. The purpose of this study was to assess how well the Patient Health Questionnaire (PHQ-9) and the Hospital Anxiety and Depression Scale (HADS) perform as depression screening tools in patients with migraine. Three hundred consecutive migraine patients were recruited from a large headache center. The PHQ-9 and HADS were self-administered and validated against the Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders-IV, a gold standard for the diagnosis of depression. Sensitivity, specificity, positive predictive value, negative predictive value and receiver-operator characteristic curves were calculated for the PHQ-9 and HADS. At the traditional cut-point of 10, the PHQ-9 demonstrated 82.0% sensitivity and 79.9% specificity. At a cut-point of 8, the HADS demonstrated 86.5% sensitivity and specificity. The PHQ-9 algorithm performed poorly (53.8% sensitivity, 94.9% specificity). The point prevalence of depression in this study was 25.0% (95% CI 19.0-31.0), and 17.0% of patients had untreated depression. In this study, the PHQ-9 and HADS performed well in migraine patients attending a headache clinic, but optimal cut-points to screen for depression vary depending on the goals of the assessment. Also, migraine patients attending a headache clinic have a high prevalence of depression and many are inadequately treated. Future studies are needed to confirm these findings and to evaluate the impact of depression screening. Copyright © 2017 Elsevier Inc. All rights reserved.
Clinical and pathological tools for identifying microsatellite instability in colorectal cancer
Krivokapić, Zoran; Marković, Srdjan; Antić, Jadranka; Dimitrijević, Ivan; Bojić, Daniela; Svorcan, Petar; Jojić, Njegica; Damjanović, Svetozar
2012-01-01
Aim To assess practical accuracy of revised Bethesda criteria (BGrev), pathological predictive model (MsPath), and histopathological parameters for detection of high-frequency of microsatellite instability (MSI-H) phenotype in patients with colorectal carcinoma (CRC). Method Tumors from 150 patients with CRC were analyzed for MSI using a fluorescence-based pentaplex polymerase chain reaction technique. For all patients, we evaluated age, sex, family history of cancer, localization, tumor differentiation, mucin production, lymphocytic infiltration (TIL), and Union for International Cancer Control stage. Patients were classified according to the BGrev, and the groups were compared. The utility of the BGrev, MsPath, and clinical and histopathological parameters for predicting microsatellite tumor status were assessed by univariate logistic regression analysis and by calculating the sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values. Results Fifteen out of 45 patients who met and 4 of 105 patients who did not meet the BGrev criteria had MSI-H CRC. Sensitivity, specificity, PPV, and NPV for BGrev were 78.9%, 77%, 30%, and 70%, respectively. MSI histology (the third BGrev criterion without age limit) was as sensitive as BGrev, but more specific. MsPath model was more sensitive than BGrev (86%), with similar specificity. Any BGrev criterion fulfillment, mucinous differentiation, and right-sided CRC were singled out as independent factors to identify MSI-H colorectal cancer. Conclusion The BGrev, MsPath model, and MSI histology are useful tools for selecting patients for MSI testing. PMID:22911525
Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S
2016-01-01
Objective: To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. Methods: A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. Results: 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83–0.88] and the specificity was 0.95 (0.93–0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44–0.51) and 0.37 (0.34–0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63–3.19). Conclusion: DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules. PMID:27759428
Bashir, Mustafa R; Merkle, Elmar M; Smith, Alastair D; Boll, Daniel T
2012-02-01
To assess whether in vivo dual-ratio Dixon discrimination can improve detection of diffuse liver disease, specifically steatosis, iron deposition and combined disease over traditional single-ratio in/opposed phase analysis. Seventy-one patients with biopsy-proven (17.7 ± 17.0 days) hepatic steatosis (n = 16), iron deposition (n = 11), combined deposition (n = 3) and neither disease (n = 41) underwent MR examinations. Dual-echo in/opposed-phase MR with Dixon water/fat reconstructions were acquired. Analysis consisted of: (a) single-ratio hepatic region-of-interest (ROI)-based assessment of in/opposed ratios; (b) dual-ratio hepatic ROI assessment of in/opposed and fat/water ratios; (c) computer-aided dual-ratio assessment evaluating all hepatic voxels. Disease-specific thresholds were determined; statistical analyses assessed disease-dependent voxel ratios, based on single-ratio (a) and dual-ratio (b and c) techniques. Single-ratio discrimination succeeded in identifying iron deposition (I/O(Ironthreshold)<0.88) and steatosis (I/O(Fatthreshold>1.15)) from normal parenchyma, sensitivity 70.0%; it failed to detect combined disease. Dual-ratio discrimination succeeded in identifying abnormal hepatic parenchyma (F/W(Normalthreshold)>0.05), sensitivity 96.7%; logarithmic functions for iron deposition (I/O(Irondiscriminator)
A multi-model assessment of terrestrial biosphere model data needs
NASA Astrophysics Data System (ADS)
Gardella, A.; Cowdery, E.; De Kauwe, M. G.; Desai, A. R.; Duveneck, M.; Fer, I.; Fisher, R.; Knox, R. G.; Kooper, R.; LeBauer, D.; McCabe, T.; Minunno, F.; Raiho, A.; Serbin, S.; Shiklomanov, A. N.; Thomas, A.; Walker, A.; Dietze, M.
2017-12-01
Terrestrial biosphere models provide us with the means to simulate the impacts of climate change and their uncertainties. Going beyond direct observation and experimentation, models synthesize our current understanding of ecosystem processes and can give us insight on data needed to constrain model parameters. In previous work, we leveraged the Predictive Ecosystem Analyzer (PEcAn) to assess the contribution of different parameters to the uncertainty of the Ecosystem Demography model v2 (ED) model outputs across various North American biomes (Dietze et al., JGR-G, 2014). While this analysis identified key research priorities, the extent to which these priorities were model- and/or biome-specific was unclear. Furthermore, because the analysis only studied one model, we were unable to comment on the effect of variability in model structure to overall predictive uncertainty. Here, we expand this analysis to all biomes globally and a wide sample of models that vary in complexity: BioCro, CABLE, CLM, DALEC, ED2, FATES, G'DAY, JULES, LANDIS, LINKAGES, LPJ-GUESS, MAESPA, PRELES, SDGVM, SIPNET, and TEM. Prior to performing uncertainty analyses, model parameter uncertainties were assessed by assimilating all available trait data from the combination of the BETYdb and TRY trait databases, using an updated multivariate version of PEcAn's Hierarchical Bayesian meta-analysis. Next, sensitivity analyses were performed for all models across a range of sites globally to assess sensitivities for a range of different outputs (GPP, ET, SH, Ra, NPP, Rh, NEE, LAI) at multiple time scales from the sub-annual to the decadal. Finally, parameter uncertainties and model sensitivities were combined to evaluate the fractional contribution of each parameter to the predictive uncertainty for a specific variable at a specific site and timescale. Facilitated by PEcAn's automated workflows, this analysis represents the broadest assessment of the sensitivities and uncertainties in terrestrial models to date, and provides a comprehensive roadmap for constraining model uncertainties through model development and data collection.
Kurosaki, Yohei; Okada, Sayaka; Nakamae, Sayuri; Yasuda, Jiro
2016-12-01
Bovine papular stomatitis virus (BPSV) causes pustular cutaneous disease in cattle worldwide. This paper describes the development of a specific loop-mediated isothermal amplification (LAMP) assay to detect BPSV which did not cross-react with other parapoxviruses. To assess analytical sensitivity of this LAMP assay, DNA was extracted from serially diluted BPSV from which the infectious titer was determined by a novel assay based on calf kidney epithelial cells. The LAMP assay had equivalent analytical sensitivity to quantitative PCR, and could detect as few as 86 copies of viral DNA per reaction. These results suggest that the assay is a specific and sensitive technique to rapidly diagnose bovine papular stomatitis in domestic animals. Copyright © 2016 Elsevier B.V. All rights reserved.
Luo, Mingxu; Lv, You; Guo, Xiuyu; Song, Hongmei; Su, Guoqiang; Chen, Bo
2017-08-01
Multidetector computed tomography (MDCT) exhibited wide ranges of sensitivities and specificities for lymph node assessment of gastric cancer (GC) in several individual studies. This present meta-analysis was carried out to evaluate the value of MDCT in diagnosis of preoperative lymph node metastasis (LNM) and to explore the impact factors that might explain the heterogeneity of its diagnostic accuracy in GC. A comprehensive search was conducted to collect all the relevant studies about the value of MDCT in assessing LNM of GC within the PubMed, Cochrane library and Embase databases up to Feb 2, 2016. Two investigators independently screened the studies, extracted data, and evaluated the quality of included studies. The sensitivity, specificity, and area under ROC curve (AUC) were pooled to estimate the overall accuracy of MDCT. Meta-regression and subgroup analysis were carried out to identify the possible factors influencing the heterogeneity of the accuracy. A total of 27 studies with 6519 subjects were finally included. Overall, the pooled sensitivity, specificity, and AUC were 0.67 (95% CI: 0.56-0.77), 0.86 (95% CI: 0.81-0.90), and 0.86 (95% CI: 0.83-0.89), respectively. Meta-regression revealed that MDCT section thickness, proportion of serosal invasion, and publication year were the main significant impact factors in sensitivity, and MDCT section thickness, multiplanar reformation (MPR), and reference standard were the main significant impact factors in specificity. After the included studies were divided into 2 groups (Group A: studies with proportion of serosa-invasive GC subjects ≥50%; Group B: studies with proportion of serosa-invasive GC subjects <50%), the pooled sensitivity in Group A was significantly higher than in Group B (0.84 [95% CI: 0.75-0.90] vs 0.55 [95% CI: 0.41-0.68], P < .01). For early gastric cancer (EGC), the pooled sensitivity, specificity, and AUC were 0.34 (95% CI: 0.15-0.61), 0.91 (95% CI: 0.84-0.95), and 0.83 (95% CI: 0.80-0.86), respectively. To summarize, MDCT tends to be adequate to assess preoperative LNM in serosa-invasive GC, but insufficient for non-serosa-invasive GC (particularly for EGC) owing to its low sensitivity. Proportion of serosa-invasive GC subjects, MDCT section thickness, MPR, and reference standard are the main factors influencing its diagnostic accuracy.
Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric
2008-09-01
Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.
Marmamula, Srinivas; Keeffe, Jill E; Narsaiah, Saggam; Khanna, Rohit C; Rao, Gullapalli N
2014-11-01
Measurements of refractive errors through subjective or automated refraction are not always possible in rapid assessment studies and community vision screening programs; however, measurements of vision with habitual correction and with a pinhole can easily be made. Although improvements in vision with a pinhole are assumed to mean that a refractive error is present, no studies have investigated the magnitude of improvement in vision with pinhole that is predictive of refractive error. The aim was to measure the sensitivity and specificity of 'vision improvement with pinhole' in predicting the presence of refractive error in a community setting. Vision and vision with pinhole were measured using a logMAR chart for 488 of 582 individuals aged 15 to 50 years. Refractive errors were measured using non-cycloplegic autorefraction and subjective refraction. The presence of refractive error was defined using spherical equivalent refraction (SER) at two levels: SER greater than ± 0.50 D sphere (DS) and SER greater than ±1.00 DS. Three definitions for significant improvement in vision with a pinhole were used: 1. Presenting vision less than 6/12 and improving to 6/12 or better, 2. Improvement in vision of more than one logMAR line and 3. Improvement in vision of more than two logMAR lines. For refractive error defined as spherical equivalent refraction greater than ± 0.50 DS, the sensitivities and specificities for the pinhole test predicting the presence of refractive error were 83.9 per cent (95% CI: 74.5 to 90.9) and 98.8 per cent (95% CI: 97.1 to 99.6), respectively for definition 1. Definition 2 had a sensitivity 89.7 per cent (95% CI: 81.3 to 95.2) and specificity 88.0 per cent (95% CI: 4.4 to 91.0). Definition 3 had a sensitivity of 75.9 per cent (95% CI: 65.5 to 84.4) and specificity of 97.8 per cent (95% CI: 95.8 to 99.0). Similar results were found with spherical equivalent refraction greater than ±1.00 DS, when tested against the three pinhole-based definitions. Refractive error definitions based on improvement in vision with the pinhole shows good sensitivity and specificity at predicting the presence of significant refractive errors. These definitions can be used in rapid assessment surveys and community-based vision screenings. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.
Preliminary development of an ultrabrief two-item bedside test for delirium.
Fick, Donna M; Inouye, Sharon K; Guess, Jamey; Ngo, Long H; Jones, Richard N; Saczynski, Jane S; Marcantonio, Edward R
2015-10-01
Delirium is common, morbid, and costly, yet is greatly under-recognized among hospitalized older adults. To identify the best single and pair of mental status test items that predict the presence of delirium. Diagnostic test evaluation study that enrolled medicine inpatients aged 75 years or older at an academic medical center. Patients underwent a clinical reference standard assessment involving a patient interview, medical record review, and interviews with family members and nurses to determine the presence or absence of Diagnostic and Statistical Manual of Mental Disorders, 4th Edition defined delirium. Participants also underwent the three-dimensional Confusion Assessment Method (3D-CAM), a brief, validated assessment for delirium. Individual items and pairs of items from the 3D-CAM were evaluated to determine sensitivity and specificity relative to the reference standard delirium diagnosis. Of the 201 participants (mean age 84 years, 62% female), 42 (21%) had delirium based on the clinical reference standard. The single item with the best test characteristics was "months of the year backwards" with a sensitivity of 83% (95% confidence interval [CI]: 69%-93%) and specificity of 69% (95% CI: 61%-76%). The best 2-item screen was the combination of "months of the year backwards" and "what is the day of the week?" with a sensitivity of 93% (95% CI: 81%-99%) and specificity of 64% (95% CI: 56%-70%). We identified a single item with >80% and pair of items with >90% sensitivity for delirium. If validated prospectively, these items will serve as an initial innovative screening step for delirium identification in hospitalized older adults. © 2015 Society of Hospital Medicine.
Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen
2012-11-15
Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Commercial VL RDTs containing bound rK39 or rKE16 antigen were evaluated using archived human sera from confirmed VL cases (n = 750) and endemic non-VL controls (n = 754) in the Indian subcontinent (ISC), Brazil, and East Africa to assess sensitivity and specificity with 95% confidence intervals. A subset of RDTs were also evaluated after 60 days' heat incubation (37°C, 45°C). Interlot and interobserver variability was assessed. All test brands performed well against ISC panels (sensitivity range, 92.8%-100%; specificity range, 96%-100%); however, sensitivity was lower against Brazil and East African panels (61.5%-91% and 36.8%-87.2%, respectively). Specificity was consistently > 95% in Brazil and ranged between 90.8% and 98% in East Africa. Performance of some products was adversely affected by high temperatures. Agreement between lots and readers was good to excellent (κ > 0.73-0.99). Diagnostic accuracy of VL RDTs varies between the major endemic regions. Many tests performed well and showed good heat stability in the ISC; however, reduced sensitivity against Brazilian and East African panels suggests that in these regions, used alone, several RDTs are inadequate for excluding a VL diagnosis. More research is needed to assess ease of use and to compare performance using whole blood instead of serum and in patients coinfected with human immunodeficiency virus.
Role of androgen ratios in the prediction of the metabolic phenotype in polycystic ovary syndrome.
Minooee, Sonia; Ramezani Tehrani, Fahimeh; Tohidi, Maryam; Azizi, Fereidoun
2017-05-01
To identify the androgen ratio that best predicts insulin resistance and metabolic syndrome among women with polycystic ovary syndrome (PCOS). Data for 180 women with PCOS and 180 healthy controls were extracted from two previous studies in Iran (conducted during 2008-2010 and 2011-2013). The diagnosis of PCOS was based on the Rotterdam criteria. The serum concentration of different androgens was measured. Receiver operating characteristic curve analysis was used to assess the ability of various androgen ratios to predict insulin resistance and metabolic syndrome. Among women with PCOS, the testosterone-to-androstenedione ratio was the best predictor of insulin resistance (sensitivity 0.83, specificity 0.42) and metabolic syndrome (sensitivity 0.85, specificity 0.70). Among healthy controls, the ratio of free androgen index to testosterone was the best predictor of insulin resistance (sensitivity 0.84, specificity 0.33) and metabolic syndrome (sensitivity 0.91, specificity 0.17). The prediction of insulin resistance and metabolic syndrome among women with PCOS was best accomplished with the testosterone-to-androstenedione ratio. © 2017 International Federation of Gynecology and Obstetrics.
Sade, Leyla Elif; Eroğlu, Serpil; Yüce, Deniz; Bircan, Aslı; Pirat, Bahar; Sezgin, Atilla; Aydınalp, Alp; Müderrisoğlu, Haldun
2014-05-01
Implementation of reliable noninvasive testing for screening cardiac allograft vasculopathy (CAV) is of critical importance. The most widely used modality, dobutamine stress echocardiography (DSE), has moderate sensitivity and specificity. The aim of this study was to assess the potential role of serial coronary flow reserve (CFR) assessment together with DSE for predicting CAV. A total of 90 studies were performed prospectively over 5 years in 23 consecutive heart transplant recipients who survived >1 year after transplantation. Assessment of CFR with transthoracic Doppler echocardiography, DSE, coronary angiography, and endomyocardial biopsy was performed annually. Results of CFR assessment and DSE were compared with angiographic findings of CAV. Acute cellular rejections were excluded by endomyocardial biopsies. CAV was detected in 17 of 90 angiograms. Mean CFR was similarly lower in both mild (CAV grade 1) and more severe (CAV grades 2 and 3) vasculopathy, but wall motion score index became higher in parallel with increasing grades of vasculopathy. Any CAV by angiography was detected either simultaneously with or later than CFR impairment, yielding 100% sensitivity for CFR. The combination of CFR and DSE increased the specificity of the latter from 64.3% to 87.2% without compromising sensitivity (77.8%). CFR is very sensitive for detecting CAV and increases the diagnostic accuracy of DSE, raising the potential for patient management tailored to risk modification and to avoid unnecessary angiographic procedures. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Mainguy, Catherine; Bellon, Gabriel; Delaup, Véronique; Ginoux, Tiphanie; Kassai-Koupai, Behrouz; Mazur, Stéphane; Rabilloud, Muriel; Remontet, Laurent; Reix, Philippe
2017-01-01
Cystic fibrosis-related diabetes (CFRD) is a late cystic fibrosis (CF)-associated comorbidity whose prevalence is increasing sharply lifelong. Guidelines for glucose metabolism (GM) monitoring rely on the oral glucose tolerance test (OGTT). However, this test is neither sensitive nor specific. The aim of this study was to compare sensitivity and specificity of different methods for GM monitoring in children and adolescents with CF. Continuous glucose monitoring system (CGMS), used as the reference method, was compared with the OGTT, intravenous glucose tolerance test (IGTT), homeostasis model assessment index of insulin resistance (HOMA-IR), homeostasis model assessment index of β-cell function (HOMA-%B) and glycated haemoglobin A1C. Patients were classified into three groups according to CGMS: normal glucose tolerance (NGT), impaired glucose tolerance (IGT) and diabetes mellitus (DM). Twenty-nine patients (median age: 13.1 years) were recruited. According to CGMS, 11 had DM, 12 IGT and six NGT, whereas OGTT identified three patients with DM and five with IGT. While 13 of 27 had insulin deficiency according to IGTT, there was 19 of 28 according to HOMA-%B. According to HOMA-IR, 12 of 28 had insulin resistance. HOMA-%B was the most sensitive method for CFRD screening [sensitivity 91% (95% CI), specificity 47% (95% CI) and negative predictive value 89% (95% CI)]. OGTT showed the weak capacity to diagnose DM in CF and should no longer be considered as the reference method for CFRD screening in patients with CF. In our study, HOMA-%B showed promising metrics for CFRD screening. Finally, CGMS revealed that pathological glucose excursions were frequent even early in life.
Grødahl, Linn Helen J; Fawcett, Louise; Nazareth, Madeleine; Smith, Richard; Spencer, Simon; Heneghan, Nicola; Rushton, Alison
2016-08-01
In adolescent athletes, low back pain has a 1-year prevalence of 57% and causes include spondylolysis and spondylolisthesis. An accurate diagnosis enables healing, prevention of progression and return to sport. To evaluate the diagnostic utility of patient history and physical examination data to identify spondylolysis and/or spondylolisthesis in athletes. Systematic review was undertaken according to published guidelines, and reported in line with PRISMA. Key databases were searched up to 13/11/15. athletic population with LBP, patient history and/or physical examination accuracy data for spondylolysis and/or spondylolisthesis, any study design including raw data. Two reviewers independently assessed risk of bias (ROB) using QUADAS-2. A data extraction sheet was pre-designed. Pooling of data and investigation for heterogeneity enabled a qualitative synthesis of data across studies. Of the eight included studies, two were assessed as low ROB, one of which also had no concerns regarding applicability. Age (<20 years) demonstrated 81% sensitivity and 44% specificity and gender (male) 73% sensitivity and 57% specificity for spondylolysis. Difficulty falling asleep, waking up because of pain, pain worse with sitting and walking all have sensitivity >75% for spondylolisthesis. Step-deformity palpation demonstrated 60-88% sensitivity and 87-100% specificity for spondylolisthesis. The one-legged hyperextension test was not supported for spondylolysis (sensitivity 50-73%, specificity 0-87%). No recommendations can be made utilising patient history data. Based on one low ROB study, step deformity palpation may be useful in diagnosing spondylolisthesis. No physical tests demonstrated diagnostic utility for spondylolysis. Further research is required. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mobility assessment: Sensitivity and specificity of measurement sets in older adults
Panzer, Victoria P.; Wakefield, Dorothy B.; Hall, Charles B.; Wolfson, Leslie I.
2011-01-01
Objective To identify quantitative measurement variables that characterize mobility in older adults, meet reliability and validity criteria, distinguish fall-risk and predict future falls. Design Observational study with 1-year weekly falls follow-up Setting Mobility laboratory Participants Community-dwelling volunteers (n=74; 65–94 years old) categorized at entry as 27 ‘Non-fallers’ or 47 ‘Fallers’ by Medicare criteria (1 injury fall or >1 non-injury falls in the previous year). Interventions None Outcome Measures Test-retest and within-subject reliability, criterion and concurrent validity; predictive ability indicated by observed sensitivity and specificity to entry fall-risk group (Falls-status), Tinetti Performance Oriented Mobility Assessment (POMA), Computerized Dynamic Posturography Sensory Organization Test (SOT) and subsequent falls reported weekly. Results Measurement variables were selected that met reliability (ICC > 0.6) and/or discrimination (p<.01) criteria (Clinical variables- Turn- steps, time, Gait- velocity, Step-in-tub-time, and Downstairs- time; Force plate variables- Quiet standing Romberg ratio sway-area, Maximal lean- anterior-posterior excursion, Sit-to-stand medial-lateral excursion and sway-area). Sets were created (3 clinical, 2 force plate) utilizing combinations of variables appropriate for older adults with different functional activity levels and composite scores were calculated. Scores identified entry Falls-status and concurred with POMA and SOT. The Full clinical set (5 measurement variables) produced sensitivity/specificity (.80/.74) to Falls-status. Composite scores were sensitive and specific in predicting subsequent injury falls and multiple falls compared to Falls-status, POMA or SOT. Conclusions Sets of quantitative measurement variables obtained with this mobility battery provided sensitive prediction of future injury falls and screening for multiple subsequent falls using tasks that should be appropriate to diverse participants. PMID:21621667
Blood DNA methylation biomarkers predict clinical reactivity in food-sensitized infants.
Martino, David; Dang, Thanh; Sexton-Oates, Alexandra; Prescott, Susan; Tang, Mimi L K; Dharmage, Shyamali; Gurrin, Lyle; Koplin, Jennifer; Ponsonby, Anne-Louise; Allen, Katrina J; Saffery, Richard
2015-05-01
The diagnosis of food allergy (FA) can be challenging because approximately half of food-sensitized patients are asymptomatic. Current diagnostic tests are excellent makers of sensitization but poor predictors of clinical reactivity. Thus oral food challenges (OFCs) are required to determine a patient's risk of reactivity. We sought to discover genomic biomarkers of clinical FA with utility for predicting food challenge outcomes. Genome-wide DNA methylation (DNAm) profiling was performed on blood mononuclear cells from volunteers who had undergone objective OFCs, concurrent skin prick tests, and specific IgE tests. Fifty-eight food-sensitized patients (aged 11-15 months) were assessed, half of whom were clinically reactive. Thirteen nonallergic control subjects were also assessed. Reproducibility was assessed in an additional 48 samples by using methylation data from an independent population of patients with clinical FA. Using a supervised learning approach, we discovered a DNAm signature of 96 CpG sites that predict clinical outcomes. Diagnostic scores were derived from these 96 methylation sites, and cutoffs were determined in a sensitivity analysis. Methylation biomarkers outperformed allergen-specific IgE and skin prick tests for predicting OFC outcomes. FA status was correctly predicted in the replication cohort with an accuracy of 79.2%. DNAm biomarkers with clinical utility for predicting food challenge outcomes are readily detectable in blood. The development of this technology in detailed follow-up studies will yield highly innovative diagnostic assays. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Rejection sensitivity prospectively predicts increased rumination.
Pearson, Katherine A; Watkins, Edward R; Mullan, Eugene G
2011-10-01
Converging research findings indicate that rumination is correlated with a specific maladaptive interpersonal style encapsulating submissive (overly-accommodating, non-assertive and self-sacrificing) behaviours, and an attachment orientation characterised by rejection sensitivity. This study examined the prospective longitudinal relationship between rumination, the submissive interpersonal style, and rejection sensitivity by comparing two alternative hypotheses: (a) the submissive interpersonal style and rejection sensitivity prospectively predict increased rumination; (b) rumination prospectively predicts the submissive interpersonal style and rejection sensitivity. Currently depressed (n = 22), previously depressed (n = 42) and never depressed (n = 28) individuals completed self-report measures assessing depressive rumination and key psychosocial measures of interpersonal style and behaviours, at baseline and again six months later. Baseline rejection sensitivity prospectively predicted increased rumination six months later, after statistically controlling for baseline rumination, gender and depression. Baseline rumination did not predict the submissive interpersonal style or rejection sensitivity. The results provide a first step towards delineating a potential casual relationship between rejection sensitivity and rumination, and suggest the potential value of clinical assessment and intervention for both rejection sensitivity and rumination in individuals who present with either difficulty. Copyright © 2011 Elsevier Ltd. All rights reserved.
Caumo, F; Carbognin, G; Casarin, A; Pinali, L; Vasori, S; D'Onofrio, M; Pozzi Mucelli, R
2006-02-01
The purpose of this study was to evaluate the accuracy of angiosonography in comparison with colour Doppler ultrasound (US) in the discrimination of suspicious breast lesions with nondiagnostic fine-needle aspiration cytology (FNAC). Pre-operative Power Doppler US and angiosonography were prospectively performed in 20 suspicious breast lesions with non-diagnostic FNAC. A second-generation US contrast agent was utilised with a high-frequency transducer and a contrast-specific algorithm (low acoustic pressure CnTI). The enhancement characteristics of all lesions were analysed using qualitative and quantitative parameters obtained from time-intensity curves with the different imaging modalities. The final diagnosis was confirmed at pathology in all cases. Microvessel density (MVD) was assessed in the surgical specimen using CD34. The correct assessment of biological behaviour was achieved in all cases by angiosonography (sensitivity of 100%; specificity of 91%) and colour Doppler US (45% sensitivity; 78% specificity). MVD correlated with the biological behaviour. Angiosonography is more accurate than colour Doppler US in the correct assessment of biological behaviour of suspicious breast lesions.
USDA-ARS?s Scientific Manuscript database
Varroa destructor continues to threaten colonies of European honey bees. General hygiene and more specific VarroaVarroa Sensitive Hygiene (VSH) provide resistance toward the Varroa mite in a number of stocks. In this study, Russian (RHB) and Italian honey bees were assessed for the VSH trait. Two...
Screening protocol for dysphagia in adults: comparison with videofluoroscopic findings.
Sassi, Fernanda C; Medeiros, Gisele C; Zilberstein, Bruno; Jayanthi, Shri Krishna; de Andrade, Claudia R F
2017-12-01
To compare the videofluoroscopic findings of patients with suspected oropharyngeal dysphagia with the results of a clinical screening protocol. A retrospective observational cohort study was conducted on all consecutive patients with suspected oropharyngeal dysphagia between March 2015 and February 2016 who were assigned to receive a videofluoroscopic assessment of swallowing. All patients were first submitted to videofluoroscopy and then to the clinical assessment of swallowing. The clinical assessment was performed within the first 24 hours after videofluoroscopy. The videofluoroscopy results were analyzed regarding penetration/aspiration using an 8-point multidimensional perceptual scale. The accuracy of the clinical protocol was analyzed using the sensitivity, specificity, likelihood ratios and predictive values. The selected sample consisted of 50 patients. The clinical protocol presented a sensitivity of 50% and specificity of 95%, with an accuracy of 88%. "Cough" and "wet-hoarse" vocal quality after/during swallowing were clinical indicators that appeared to correctly identify the presence of penetration/aspiration risk. The clinical protocol used in the present study is a simple, rapid and reliable clinical assessment. Despite the absence of a completely satisfactory result, especially in terms of the sensitivity and positive predictive values, we suggest that lower rates of pneumonia can be achieved using a formal dysphagia screening method.
Bernhoff, Gabriella; Landén Ludvigsson, Maria; Peterson, Gunnel; Bertilson, Bo Christer; Elf, Madeleine; Peolsson, Anneli
2016-01-01
The aim of the study was to investigate the psychometric properties of a standardized assessment of pain drawing with regard to clinical signs of cervical spine nerve root involvement. This cross-sectional study included data collected in a randomized controlled study. Two hundred and sixteen patients with chronic (≥6 months) whiplash-associated disorders, grade 2 or 3, were included in this study. The validity, sensitivity, and specificity of a standardized pain drawing assessment for determining nerve root involvement were analyzed, compared to the clinical assessment. In addition, we analyzed the interrater reliability with 50 pain drawings. Agreement was poor between the standardized pain drawing assessment and the clinical assessment (kappa =0.11, 95% CI: -0.03 to 0.20). Sensitivity was high (93%), but specificity was low (19%). Interrater reliability was good (kappa =0.64, 95% CI: 0.53 to 0.76). The standardized pain drawing assessment of nerve root involvement in chronic whiplash-associated disorders was not in agreement with the clinical assessment. Further research is warranted to optimize the utilization of a pain/discomfort drawing as a supportive instrument for identifying nerve involvement in cervical spinal injuries.
Kinoshita, Kensuke; Hattori, Kazuya; Ota, Yoshio; Kanai, Takao; Shimizu, Miyuki; Kobayashi, Hiroyuki; Tokuda, Yasuharu
2013-02-01
Dry axilla can sometimes be found among dehydrated older patients. In this study, we measured the axillary moisture and assessed it as possible marker for dehydration. Twenty-nine older patients admitted with acute medical conditions participated in this study. Dehydration was diagnosed by the calculated serum osmolality of greater than 295 mOsm/L. The moisture of axilla was measured by a skin moisture impedance meter which was applied at the center of axilla of patients. 11 patients (7 males and 4 females) were diagnosed as dehydrated and 18 patients (10 males and 8 females) were diagnosed as non-dehydrated. The mean axillary moisture (33%) in the dehydrated group was significantly lower than that (42%) in the non-dehydrated group (p<0.05). The axillary moisture ≥50% showed the sensitivity of 88%. The axillary moisture <30% showed the specificity of 91%. Use of a single cutoff value of 40% moisture produced the sensitivity of 59% and the specificity of 9%. As for the physical signs, dry axilla had also moderate sensitivity and excellent specificity to detect dehydration. The measurement of the axillary moisture could help assess dehydration. Dehydration could be ruled out when the axillary moisture ≥50%, while it could be ruled-in when the axillary moisture is <30%. Copyright © 2012 Elsevier Inc. All rights reserved.
Incremental Validity in the Clinical Assessment of Early Childhood Development
ERIC Educational Resources Information Center
Liu, Xin; Zhou, Xiaobin; Lackaff, Julie
2013-01-01
The authors demonstrate the increment of clinical validity in early childhood assessment of physical impairment (PI), developmental delay (DD), and autism (AUT) using multiple standardized developmental screening measures such as performance measures and parent and teacher rating scales. Hierarchical regression and sensitivity/specificity analyses…
Assessment of BCG vaccination in India
1957-01-01
A second assessment of the mass BCG-vaccination campaign in India is described in this report. Data were collected to corroborate the findings of the first assessment and to study certain aspects of the problems they posed. Sample retesting of children vaccinated in the mass campaign reveals a higher and less variable allergy than that reported from the preliminary assessment work. The results indicate that a uniform and reasonably high level of allergy has been induced in Indian schoolchildren vaccinated in the campaign period assessed and that deficiencies in the tuberculin test by which the allergy was measured rather than defects of vaccine or vaccination technique were responsible for the disappointing variability initially reported. Testing of unvaccinated village populations in Madras and Mysore confirms previous observations that low-grade, non-specific tuberculin sensitivity is widely prevalent in South India, making it virtually impossible to separate the infected from the uninfected with the tuberculin tests in use today. The development of new techniques for use in areas where the low-grade, non-specific sensitivity is widespread is discussed. PMID:13489464
Photoacoustic and ultrasound characterization of bone composition
NASA Astrophysics Data System (ADS)
Lashkari, Bahman; Yang, Lifeng; Liu, Lixian; Tan, Joel W. Y.; Mandelis, Andreas
2015-02-01
This study examines the sensitivity and specificity of backscattered ultrasound (US) and backscattering photoacoustic (PA) signals for bone composition variation assessment. The conventional approach in the evaluation of bone health relies on measurement of bone mineral density (BMD). Although, a crucial and probably the most important parameter, BMD is not the only factor defining the bone health. New trends in osteoporosis research, also pursue the changes in collagen content and cross-links with bone diseases and aging. Therefore, any non-invasive method that can assess any of these parameters can improve the diagnostic tools and also can help with the biomedical studies on the diseases themselves. Our previous studies show that both US and PA are responsive to changes in the BMD, PA is, in addition, sensitive to changes in the collagen content of the bone. Measurements were performed on bone samples before and after mild demineralization and decollagenization at the exact same points. Results show that combining both modalities can enhance the sensitivity and specificity of diagnostic tool.
Erdodi, Laszlo A; Abeare, Christopher A; Lichtenstein, Jonathan D; Tyson, Bradley T; Kucharski, Brittany; Zuccato, Brandon G; Roth, Robert M
2017-02-01
Research suggests that select processing speed measures can also serve as embedded validity indicators (EVIs). The present study examined the diagnostic utility of Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV) subtests as EVIs in a mixed clinical sample of 205 patients medically referred for neuropsychological assessment (53.3% female, mean age = 45.1). Classification accuracy was calculated against 3 composite measures of performance validity as criterion variables. A PSI ≤79 produced a good combination of sensitivity (.23-.56) and specificity (.92-.98). A Coding scaled score ≤5 resulted in good specificity (.94-1.00), but low and variable sensitivity (.04-.28). A Symbol Search scaled score ≤6 achieved a good balance between sensitivity (.38-.64) and specificity (.88-.93). A Coding-Symbol Search scaled score difference ≥5 produced adequate specificity (.89-.91) but consistently low sensitivity (.08-.12). A 2-tailed cutoff on the Coding/Symbol Search raw score ratio (≤1.41 or ≥3.57) produced acceptable specificity (.87-.93), but low sensitivity (.15-.24). Failing ≥2 of these EVIs produced variable specificity (.81-.93) and sensitivity (.31-.59). Failing ≥3 of these EVIs stabilized specificity (.89-.94) at a small cost to sensitivity (.23-.53). Results suggest that processing speed based EVIs have the potential to provide a cost-effective and expedient method for evaluating the validity of cognitive data. Given their generally low and variable sensitivity, however, they should not be used in isolation to determine the credibility of a given response set. They also produced unacceptably high rates of false positive errors in patients with moderate-to-severe head injury. Combining evidence from multiple EVIs has the potential to improve overall classification accuracy. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Masked Repetition Priming Using Magnetoencephalography
ERIC Educational Resources Information Center
Monahan, Philip J.; Fiorentino, Robert; Poeppel, David
2008-01-01
Masked priming is used in psycholinguistic studies to assess questions about lexical access and representation. We present two masked priming experiments using MEG. If the MEG signal elicited by words reflects specific aspects of lexical retrieval, then one expects to identify specific neural correlates of retrieval that are sensitive to priming.…
The association of allergic sensitization in mother and child in breast-fed and formula-fed infants.
Wright, A L; Stern, D A; Halonen, M
2001-01-01
Human milk contains immunologically active substances potentially capable of altering infant immune response. As part of the prospective Children's Respiratory Study, we assessed whether the association between maternal allergic status and allergic status of the child was altered by breast-feeding. Skin-prick tests for 7 common allergens were administered to 702 6-year-old children and their mothers. The percentage of children sensitized to specific allergens, maternal skin test response to that allergen, and whether or not the child was ever breast-fed was determined. Findings indicated that specific sensitization in the mother was associated with specific sensitization in the child only if the child was breast-fed. This indirectly supports the hypothesis that contents of milk differ with maternal allergic status, and appear to affect allergic status in the child. These results suggest that milk from allergic mothers either promotes a Th2 type immune response or suppresses Th1 immune response in the child.
Burgos, Joaquin; Hernández-Losa, Javier; Landolfi, Stefania; Guelar, Ana; Dinares, MªCarmen; Villar, Judith; Navarro, Jordi; Ribera, Esteve; Falcó, Vicenç; Curran, Adria
2017-10-23
To assess the oncogenic human papillomavirus (HPV) determination and the cotesting HPV and anal cytology value to detect high-grade anal intraepithelial neoplasia (HGAIN) in a cohort of HIV-MSM. Prospective study of HIV-infected MSM who underwent screening for anal dysplasia. Screening program includes anal cytology, HPV testing, and high-resolution anoscopy (HRA) at each visit. Histological samples were obtained if suspicious lesions were revealed by HRA. Sensitivity and specificity of the different tests were calculated by using histological results of HRA-guided biopsy as the reference test for HGAIN diagnosis. From May 2009 to August 2016, 692 HIV-infected MSM underwent 1827 anal cytologies, 1841 HRA examinations, and 1607 HPV testing. At first screening visit, anal cytology results were abnormal in 418 (60.4%) of 692 patients, and oncogenic HPV genotypes were found in 482 (79.5%) of 606 patients. Anal cytology showed a sensitivity of 89.2% [95% confidence interval (CI); 80.7-94.2] and a specificity of 44.2% (95% CI; 40.2-48.2) to detect HGAIN. Oncogenic HPV testing had 90.4% sensitivity (95% CI; 82-86.8) and 24.4% specificity (95% CI; 20.8-28.3). Cotesting showed a 97.4% sensitivity (95% CI; 91-99.3) and 14% specificity (95% CI; 11.2-17.3). In patients with atypical squamous cells of uncertain significance on cytology, oncogenic HPV testing had 91.3% sensitivity and 28.3% specificity to detect HGAIN. Abnormal cytology and oncogenic HPV determination showed similar sensitivity for detecting HGAIN. The two tests used together improved the sensitivity but with lowered specificity. In our opinion, HPV testing does not improve HGAIN detection and should not replace anal cytology as a standard screening test for HIV-infected MSM.
Kanoto, Masafumi; Sugai, Yukio; Hosoya, Takaaki; Toyoguchi, Yuuki; Konno, Yoshihiro; Watarai, Fumika; Ito, Tsukasa; Watanabe, Tomoo; Kakehata, Seiji
2015-12-01
Cholesteatomas show high intensity in diffusion-weighted imaging (DWI). We performed fused thin slice non-echo planar imaging (EPI) DWI and magnetic resonance cisternography (FTS-nEPID) for cholesteatoma patients to increase the detectability of FTS-nEPID for cholesteatoma. The subjects are 77 consecutive patients who underwent FTS-nEPID as a preoperative study (mean age: 53.3±21.8, 47 men and 30 women). Otorhinolaryngologists performed the operations. We anatomically classified the middle ear into four portions. A radiologist evaluated the images for cholesteatoma and assessed the anatomical invasive range in four portions using only FTS-nEPID. We classified large cholesteatomas that invaded more than three portions and small ones that invaded less than two portions based on the results obtained from surgery, and calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). For all cholesteatomas with an existing diagnosis, the sensitivity, specificity, PPV, and NPV were 71%, 70%, 94%, and 27%, respectively. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 49%, 85%, 77%, and 64%, respectively. For large cholesteatomas with an existing diagnosis, the sensitivity was 86%. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 51%, 57%, 88%, and 18%, respectively. For small cholesteatomas with an existing diagnosis, the sensitivity, specificity, PPV, and NPV were 59%, 78%, 92%, and 30%, respectively. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 40%, 85%, 60%, and 71%, respectively. FTS-nEPID may be useful for diagnosing cholesteatomas. Further research is needed for anatomical evaluation because there were many false-negative results. Copyright © 2015 Elsevier Inc. All rights reserved.
Elahi, Rubayet; Mohon, Abu Naser; Khan, Wasif A; Haque, Rashidul; Alam, Mohammad Shafiul
2013-10-30
The rapid diagnostic test (RDT) has been adopted in contemporary malaria control and management programmes around the world as it represents a fast and apt alternative for malaria diagnosis in a resource-limited setting. This study assessed the performance of a HRP-2/pLDH based RDT (Parascreen® Pan/Pf) in a laboratory setting utilizing clinical samples obtained from the field. Whole blood samples were obtained from febrile patients referred for malaria diagnosis by clinicians from two different Upazila Health Complexes (UHCs) located near the Bangladesh-India and Bangladesh-Myanmar border where malaria is endemic. RDT was performed on archived samples and sensitivity and specificity evaluated with expert microscopy (EM) and quantitative PCR (qPCR). A total of 327 clinical samples were made available for the study, of which 153 were Plasmodium falciparum-positive and 54 were Plasmodium vivax-positive. In comparison with EM, for P. falciparum malaria, the RDT had sensitivity: 96.0% (95% CI, 91.2-98.3) and specificity: 98.2% (95% CI, 94.6-99.5) and for P. vivax, sensitivity: 90.7% (95% CI, 78.9-96.5) and specificity: 98.9% (95% CI, 96.5-99.7). Comparison with qPCR showed, for P. falciparum malaria, sensitivity: 95.4% (95% CI, 90.5-98.0) and specificity: 98.8% (95% CI, 95.4-99.7) and for P. vivax malaria, sensitivity: 89.0% (95% CI,77.0-95.4) and specificity: 98.8% (95% CI, 96.5-99.7). Sensitivity varied according to different parasitaemia for falciparum and vivax malaria diagnosis. Parascreen® Pan/Pf Rapid test for malaria showed acceptable sensitivity and specificity in border belt endemic areas of Bangladesh when compared with EM and qPCR.
Lippi, Giuseppe; Mattiuzzi, Camilla; Cervellin, Gianfranco
2013-01-01
An early diagnosis is crucial for effective triage and management of patients with suspected acute myocardial infarction (AMI). Although troponin testing is the cornerstone of diagnosis, the sensitivity of this biomarker is still suboptimal at patient admission. The heart-type fatty acid binding protein (H-FABP) is an early and sensitive biomarker of myocardial ischemia, whose appropriate setting is in combination with troponin testing. We performed a systematic review and meta-analysis of articles that have assessed the combination of troponin and H-FABP in the early diagnosis of AMI. Eight studies, totaling 2735 patients, met the inclusion criteria but none of them used a high-sensitivity troponin immunoassay. The between-study variation was high (98.5%), and attributable to heterogeneity. When considered alone, troponin exhibited a significantly greater pooled area under the curve (AUC) than H-FABP alone (0.820 versus 0.784; p<0.001). The pooled specificity was also higher for troponin alone than for H-FABP alone (0.94 versus 0.83; p<0.001), whereas the cumulative sensitivity was lower for troponin than for H-FABP (0.73 versus 0.80; p=0.02). The combination of both biomarkers exhibited a greater AUC than troponin alone (0.881; p<0.001), as well as a higher pooled sensitivity (0.91; p<0.001), which was however counterbalanced by a lower specificity (0.82; p<0.001). These results attest that the combination of H-FABP with a conventional troponin immunoassay seems advantageous for increasing the sensitivity of the former biomarker, at the expense of a lower specificity. The introduction of H-FABP testing would hence require careful assessment of laboratory data or clinical signs and symptoms for excluding sources of elevation different from AMI. Further studies are needed to assess the diagnostic effectiveness of combining H-FABP with a high-sensitivity troponin immunoassay. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Dastych, Milan; Dastych, Milan; Novotná, Hana; Cíhalová, J
2008-10-01
The purpose of this study was to investigate and compare the specificity, sensitivity, and area under curve (AUC) of the lactulose/mannitol ratio, lactulose/creatinine ratio, and lactulose recovery and their diagnostic value for intestinal permeability assessment within the absorption lactulose/mannitol (L/M) test. The value of the lactulose/mannitol ratio, lactulose/creatinine ratio, and the percentage of lactulose recovery in Crohn's disease (0.0763 +/- 0.0369; 99.62 +/- 67.87; 1.0478 +/- 0.6148) and in liver cirrhosis (0.0517 +/- 0.0365; 54.65 +/- 53.26; 0.838 +/- 0.929) were significantly different from the values measured in the control group (0.0123 +/- 0.0081; 10.95 +/- 7.07; 0.2438 +/- 0.1568), P < 0.0001-0.002). In Crohn's disease, specificity, sensitivity, and AUC were 100%, 89.5%, and 0.987, respectively, of the lactulose/mannitol ratio at a cut-off level of 0.022. In liver cirrhosis, the test characteristics were 88.5%, 84.2%, and 0.910 at a cut-off level of 0.018. The lactulose/mannitol ratio was evaluated to have the highest diagnostic value to assess intestinal permeability.
Husain, Shahid; Kwak, Eun Jeong; Obman, Asia; Wagener, Marilyn M; Kusne, Shimon; Stout, Janet E; McCurry, Kenneth R; Singh, Nina
2004-05-01
The clinical utility of Platelia trade mark Aspergillus galactomannan antigen for the early diagnosis of invasive aspergillosis was prospectively assessed in 70 consecutive lung transplant recipients. Sera were collected twice weekly and tested for galactomannan. Invasive aspergillosis was documented in 17.1% (12/70) of the patients. Using the generalized estimating equation model, at the cutoff value of >or= 0.5, the sensitivity of the test was 30%, specificity 93% with positive and negative likelihood ratios of 4.2 and 0.75, respectively. Increasing the cutoff value to >or= 0.66 yielded a sensitivity of 30%, specificity of 95%, and positive and negative likelihood ratios of 5.5 and 0.74. A total of 14 patients had false-positive tests, including nine who had cystic fibrosis or chronic obstructive pulmonary disease. False-positive tests occurred within 3 days of transplantation in 43% (6/14) of the patients, and within 7 days in 64% (9/14). Thus, the test demonstrated excellent specificity, but a low sensitivity for the diagnosis of aspergillosis in this patient population. Patients with cystic fibrosis or chronic obstructive pulmonary disease may transiently have a positive test in the early post-transplant period.
Müller, Matthias J; Müller, Kay-Maria; Fellgiebel, Andreas
2006-05-01
To compare the psychometric properties of the Calgary Depression Rating Scale (CDRS) and the Hamilton Depression Rating Scale (HDRS) for severity assessment of depression in acute schizophrenia. During clinical routine treatment, we investigated 119 inpatients with acute schizophrenia, using the CDRS, the HDRS, and a global 4-point Depression Severity Scale (DEP-SEV). We compared CDRS and HDRS sum scores regarding their diagnostic accuracy, with global severity of depression as the criterion. We estimated sensitivity and specificity on the basis of receiver operating characteristic curves. According to global clinical ratings (DEP-SEV), 31% of patients had no depression, 19% had mild, 31% had moderate, and 19% had severe depression. Sensitivity was significantly higher (P < 0.05) for the CDRS than for the HDRS to assess mild (0.94 vs 0.76, cut-off 3 vs 10 points) or severe depression (1.00 vs 0.78, cut-off 11 vs 22 points); specificity was comparably high (> or = 0.88) for both scales. Despite the fact that both scales were effective in separating mild, moderate, and severe depression, significant advantages emerged for the CDRS to detect mild or severe depression in schizophrenia.
Identification of the need for home visiting nurse: development of a new assessment tool.
Taguchi, Atsuko; Nagata, Satoko; Naruse, Takashi; Kuwahara, Yuki; Yamaguchi, Takuhiro; Murashima, Sachiyo
2014-01-01
To develop a Home Visiting Nursing Service Need Assessment Form (HVNS-NAF) to standardize the decision about the need for home visiting nursing service. The sample consisted of older adults who had received coordinated services by care managers. We defined the need for home visiting nursing service by elderly individuals as the decision of the need by a care manager so that the elderly can continue to live independently. Explanatory variables included demographic factors, medical procedure, severity of illness, and caregiver variables. Multiple logistic regression was carried out after univariate analyses to decide the variables to include and the weight of each variable in the HVNS-NAF. We then calculated the sensitivity and specificity of each cutoff value, and defined the score with the highest sensitivity and specificity as the cutoff value. Nineteen items were included in the final HVNS-NAF. When the cutoff value was 2 points, the sensitivity was 77.0%, specificity 68.5%, and positive predictive value 56.8%. HVNS-NAF is the first validated standard based on characteristics of elderly clients who required home visiting nursing service. Using the HVNS-NAF may result in reducing the unmet need for home visiting nursing service and preventing hospitalization.
Zaratiegui, Rodolfo M; Vázquez, Gustavo H; Lorenzo, Laura S; Marinelli, Marcia; Aguayo, Silvia; Strejilevich, Sergio A; Padilla, Eduardo; Goldchluk, Aníbal; Herbst, Luis; Vilapriño, Juan J; Bonetto, Gerardo García; Cetkovich-Bakmas, Marcelo G; Abraham, Estela; Kahn, Clara; Whitham, Elizabeth A; Holtzman, Niki S; Ghaemi, Nassir
2011-08-01
To assess the sensitivity and specificity of two self-report instruments for detection of bipolarity in a sample of Argentinean patients. Spanish versions of the MDQ and the BSDS were administered over four months at 11 sites in Argentina. Diagnoses were made using DSM-IV criteria and the MINI. The study sample consisted of patients diagnosed with Bipolar Disorder (BD) Types I, II, or NOS. BDNOS diagnoses were made using extended guidelines for bipolar spectrum symptoms. Unipolar patients were used as a control group. Of 493 patients screened, 354 completed evaluation by MDQ and MINI, and 363 by BSDS and MINI. Specificity of MDQ was 0.97 and BSDS was 0.81. MDQ sensitivity was 0.70 for bipolar type I (BD-I), 0.52 for bipolar II (BD-II) and 0.31 for bipolar not otherwise specified (BDNOS). BSDS sensitivities were 0.75, 0.70 and 0.51 respectively. This study was performed in specialized outpatient settings and thus its results are not necessarily representative for other clinical settings. There was not a systematic evaluation of comorbid psychiatric disease or test-retest reliability. The local versions of the MDQ and the BSDS showed a sensitivity and specificity comparable to previous research. Our results indicate that in this sample, MDQ was more specific for BD and BSDS was more sensitive to detect BD-II and NOS. Since BD-I is more readily recognized than bipolar spectrum disorders, enhanced sensitivity of BSDS for soft bipolarity may be an advantage. Copyright © 2011 Elsevier B.V. All rights reserved.
Grezina, N Iu; Suleĭmenova, G M
2011-01-01
The objective of the present study was to evaluate sensitivity and specificity of the HemDirect method on test-plates (Seratec) for detecting human hemoglobin (HHb). These characteristics were compared with those of other widely used methods designed for the detection of blood traces, viz. thin layer chromatography, hemotest, spectrofluorimetry, and identification of blood species specificity (by countercurrent immunoelectrophoresis in agar and on the acetate-cellulose film). It was shown that the HemDirect test is highly specific and far more sensitive than other techniques used for the same purpose in the practical work. It can be recommended as the method of choice for the detection of blood microtraces.
Serdt, Mojca; Lejko Zupanc, Tatjana; Korošec, Aleš; Klavs, Irena
2016-12-01
The second Slovenian national healthcare-associated infections (HAIs) prevalence survey (SNHPS) was conducted in acute-care hospitals in 2011. The objective was to assess the sensitivity and specificity of the method used for the ascertainment of six types of HAIs (bloodstream infections, catheter-associated infections, lower respiratory tract infections, pneumoniae, surgical site infections, and urinary tract infections) in the University Medical Centre Ljubljana (UMCL). A cross-sectional study was conducted in patients surveyed in the SNHPS in the UMCL using a retrospective medical chart review (RMCR) and European HAIs surveillance definitions. Sensitivity and specificity of the method used in the SNHPS using RMCR as a reference was computed for ascertainment of patients with any of the six selected types of HAIs and for individual types of HAIs. Agreement between the SNHPS and RMCR results was analyzed using Cohen's kappa coefficient. 1474 of 1742 (84.6%) patients surveyed in the SNHPS were included in RMCR. The sensitivity of the SNHPS method for detecting any of six HAIs was 90% (95% confidence interval (CI): 81%-95%) and specificity 99% (95% CI: 98%-99%). The sensitivity by type of HAI ranged from 63% (lower respiratory tract infections) to 92% (bloodstream infections). Specificity was at least 99% for all types of HAIs. Agreement between the two data collection approaches for HAIs overall was very good (κ=0.83). The overall sensitivity of SNHPS collection method for ascertaining HAIs overall was high and the specificity was very high. This suggests that the estimated prevalence of HAIs in the SNHPS was credible.
Mitchell, Rebecca; Thomas, Sunethra Devika; Langlois, Neil E I
2013-10-01
Biochemical analysis of glucose and ketones in the vitreous humour obtained at post-mortem examination is representative of the levels in the blood prior to death. Elevated levels can be indicative of conditions including diabetic ketoacidosis, which can be a cause for unexpected death. A rapid screening test for such conditions can be performed during the autopsy through urinalysis using test strips (urine 'dipstick' testing). The aim of this study was to assess the utility of urinalysis testing for post-mortem detection of derangements of glucose and ketone levels. The results of vitreous biochemical analysis and urinalysis were collated from 188 forensic autopsy cases. A vitreous glucose result of above 10 mmol/L was regarded as high. When this was compared to urinalysis results it was found that any urinalysis result above negative had a sensitivity of 0.83 and a specificity of 0.93. A vitreous ketone level of above 5 mmol/L was regarded as significantly elevated; a urinalysis result above negative had a sensitivity of 1, but a specificity of 0.12. Urinalysis ('dipstick' testing) for glucose has a good sensitivity and specificity for high vitreous glucose levels, which are regarded as indicative of pathological hyperglycaemia during life. It was found that urine testing for ketones either has an excellent sensitivity with low specificity or a poor sensitivity with a good specificity; however, this finding has to be viewed in the context of uncertainty of the biochemical level of significant ketosis.
Salisbury, Louisa A; Nyce, Jonathan D; Hannum, Charles D; Sheldrick, R Christopher; Perrin, Ellen C
2018-04-01
Autism screening is recommended by the American Academy of Pediatrics and the Centers for Disease Control and Prevention at ages 18 and 24 months. Popular screening tests have been validated for the age range of 16 to 30 months. However, only a minority of children with autism spectrum disorder (ASD) are identified by age 3 years, and many are not identified until after they enter school. Thus, we aimed to measure the sensitivity and specificity of 2 available screening tests for ASDs in children older than 30 months. We assessed the sensitivity and specificity of 2 ASD screening tools administered to parents of children who were referred to a developmental clinic between the ages of 16 and 48 months: the Modified Checklist for Autism in Toddlers (M-CHAT) and the Parent's Observations of Social Interactions (POSI), which is a component of a comprehensive screening instrument called, the Survey of Well-being of Young Children. Both the M-CHAT and the POSI had acceptable sensitivity (≥75%) among children across the age range studied. Their specificity was limited by the fact that the study was conducted in a developmental referral clinic. Two readily available screening tools, the POSI and the M-CHAT, have acceptable sensitivity in evaluating risk for autism in children at least to age 48 months. Further research should investigate their sensitivity and specificity when used in primary care settings.
[Sensitization to chymopapain in patients treated with chemonucleolysis].
García-Ortega, P; Ramírez Ferreiras, W; Sancho, A; Urías, S; Cisteró, A
1991-03-23
Chemonucleolysis (intradisk administration of chymopapain) is a procedure to treat intervertebral disk hernia. Recently, its use has been questioned due to the development of anaphylactic reactions in patients sensitized to chymopapain. The prevalence of sensitization to chymopapain has been evaluated before and after chemonucleolysis, and the possibility to establish risk groups through the allergy history has been assessed. 104 consecutive patients who were candidates to chemonucleolysis were evaluated with an allergy questionnaire, cutaneous tests to aeroallergens and to chymopapain, and chymopapain-specific IgE. The two latter tests were repeated one month after chemonucleolysis. Only 2 patients (1.9%) showed evidence of chymopapain sensitization before the procedure. Sixteen patients (16%) were sensitized after chemonucleolysis. None of the possible risk factors evaluated in the allergy questionnaire (atopy, drug allergy, papaya occupational exposure or use of additives, cosmetics or drugs containing papaine) were significantly related with the risk of sensitization to chymopapain. The prevalence of chymopapain sensitization in the study group was low. The allergy questionnaire (atopy, drug allergy, use of papaya, occupational history did not identify sensitized patients. Cutaneous tests and specific IgE are the best method to detect chymopapain sensitization. The remarkable rate of sensitization after chemonucleolysis may partially limit the usefulness of the procedure.
Pugliese, Cara E; Kenworthy, Lauren; Bal, Vanessa Hus; Wallace, Gregory L; Yerys, Benjamin E; Maddox, Brenna B; White, Susan W; Popal, Haroon; Armour, Anna Chelsea; Miller, Judith; Herrington, John D; Schultz, Robert T; Martin, Alex; Anthony, Laura Gutermuth
2015-12-01
Recent updates have been proposed to the Autism Diagnostic Observation Schedule-2 Module 4 diagnostic algorithm. This new algorithm, however, has not yet been validated in an independent sample without intellectual disability (ID). This multi-site study compared the original and revised algorithms in individuals with ASD without ID. The revised algorithm demonstrated increased sensitivity, but lower specificity in the overall sample. Estimates were highest for females, individuals with a verbal IQ below 85 or above 115, and ages 16 and older. Best practice diagnostic procedures should include the Module 4 in conjunction with other assessment tools. Balancing needs for sensitivity and specificity depending on the purpose of assessment (e.g., clinical vs. research) and demographic characteristics mentioned above will enhance its utility.
NASA Astrophysics Data System (ADS)
Winardi, A. M.; Wulansari, L. K.; Kusdhany, L. S.
2017-08-01
Osteoporosis must be detected early in order to prevent failures in denture treatment. To this end, tools such as the Posture-P questionnaire and the Quantitative Ultrasound (QUS) are widely used for osteoporosis screening. Posture-P. This study is a diagnostic test that analyzes the sensitivity and specificity of the Posture-P questionnaire towards QUS in assessing the bone density of postmenopausal women. Data was collected through interviews using the Posture-P questionnaire, and bone density was measured using the QUS. The results of this study show that both the sensitivity and specificity of the Posture-P questionnaire towards QUS are quite good, with respective values of 77.23% and 75%. Thus, the Posture-P questionnaire can replace the QUS in osteoporosis screening.
Ianculescu, Victor; Ciolovan, Laura Maria; Dunant, Ariane; Vielh, Philippe; Mazouni, Chafika; Delaloge, Suzette; Dromain, Clarisse; Blidaru, Alexandru; Balleyguier, Corinne
2014-05-01
To determine the diagnostic performance of Acoustic Radiation Force Impulse (ARFI) Virtual Touch IQ shear wave elastography in the discrimination of benign and malignant breast lesions. Conventional B-mode and elasticity imaging were used to evaluate 110 breast lesions. Elastographic assessment of breast tissue abnormalities was done using a shear wave based technique, Virtual Touch IQ (VTIQ), implemented on a Siemens Acuson S3000 ultrasound machine. Tissue mechanical properties were interpreted as two-dimensional qualitative and quantitative colour maps displaying relative shear wave velocity. Wave speed measurements in m/s were possible at operator defined regions of interest. The pathologic diagnosis was established on samples obtained by ultrasound guided core biopsy or fine needle aspiration. BIRADS based B-mode evaluation of the 48 benign and 62 malignant lesions achieved 92% sensitivity and 62.5% specificity. Subsequently performed VTIQ elastography relying on visual interpretation of the colour overlay displaying relative shear wave velocities managed similar standalone diagnostic performance with 92% sensitivity and 64.6% specificity. Lesion and surrounding tissue shear wave speed values were calculated and a significant difference was found between the benign and malignant populations (Mann-Whitney U test, p<0.0001). By selecting a lesion cut-off value of 3.31m/s we achieved 80.4% sensitivity and 73% specificity. Applying this threshold only to BIRADS 4a masses, we reached overall levels of 92% sensitivity and 72.9% specificity. VTIQ qualitative and quantitative elastography has the potential to further characterise B-mode detected breast lesions, increasing specificity and reducing the number of unnecessary biopsies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Kühn, Andreas; Meierhofer, Christian; Rutz, Tobias; Rondak, Ina-Christine; Röhlig, Christoph; Schreiber, Christian; Fratz, Sohrab; Ewert, Peter; Vogt, Manfred
2016-08-01
Ebstein's anomaly (EA) is often associated with right ventricular (RV) dysfunction. Data on echocardiographic quantification of RV function are, however, rare. The aim of this study was to determine how non-volumetric echocardiographic indices and qualitative assessment of global systolic RV function correlate with cardiovascular magnetic resonance (CMR)-derived RV ejection fraction (EF). We compared six echocardiographic indices and qualitative assessment of RV function with the gold standard CMR. A total of 49 unoperated patients with EA and a mean age of 32 ± 18 years were examined. Tricuspid annular plane systolic excursion, tissue Doppler myocardial velocities (peak S and IVA) and 2D strain and strain rate measures for the RV were compared with CMR-derived EF. Only 2D global longitudinal strain (2D-GLS), out of the six parameters investigated, showed a weak, although statistically significant correlation with CMR-derived RVEF (R = -0.4, P = 0.01). Using a cut-off value of -20.15, 2D-GLS sensitivity (77%) and specificity (46%) in detecting patients with a CMR-derived EF of <50% were comparable with qualitative assessment (sensitivity 77%, specificity 45%). Overall echocardiographic parameters of RV function correlate poorly with CMR-derived EF in patients with EA. Only 2D global longitudinal RV strain correlated weakly with CMR-derived RVEF. However, the sensitivity and specificity for detecting RV dysfunction using 2D strain imaging were comparable with qualitative RV functional assessment. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Psychoacoustic Assessment to Improve Tinnitus Diagnosis
Hutchins, Sean; Hébert, Sylvie
2013-01-01
The diagnosis of tinnitus relies on self-report. Psychoacoustic measurements of tinnitus pitch and loudness are essential for assessing claims and discriminating true from false ones. For this reason, the quantification of tinnitus remains a challenging research goal. We aimed to: (1) assess the precision of a new tinnitus likeness rating procedure with a continuous-pitch presentation method, controlling for music training, and (2) test whether tinnitus psychoacoustic measurements have the sensitivity and specificity required to detect people faking tinnitus. Musicians and non-musicians with tinnitus, as well as simulated malingerers without tinnitus, were tested. Most were retested several weeks later. Tinnitus pitch matching was first assessed using the likeness rating method: pure tones from 0.25 to 16 kHz were presented randomly to participants, who had to rate the likeness of each tone to their tinnitus, and to adjust its level from 0 to 100 dB SPL. Tinnitus pitch matching was then assessed with a continuous-pitch method: participants had to match the pitch of their tinnitus to an external tone by moving their finger across a touch-sensitive strip, which generated a continuous pure tone from 0.5 to 20 kHz in 1-Hz steps. The predominant tinnitus pitch was consistent across both methods for both musicians and non-musicians, although musicians displayed better external tone pitch matching abilities. Simulated malingerers rated loudness much higher than did the other groups with a high degree of specificity (94.4%) and were unreliable in loudness (not pitch) matching from one session to the other. Retest data showed similar pitch matching responses for both methods for all participants. In conclusion, tinnitus pitch and loudness reliably correspond to the tinnitus percept, and psychoacoustic loudness matches are sensitive and specific to the presence of tinnitus. PMID:24349414
Eisele, Thomas P.; Silumbe, Kafula; Yukich, Josh; Hamainza, Busiku; Keating, Joseph; Bennett, Adam; Miller, John M.
2013-01-01
Background To assess progress in the scale-up of rapid diagnostic tests and artemisinin-based combination therapies (ACTs) across Africa, malaria control programs have increasingly relied on standardized national household surveys to determine the proportion of children with a fever in the past 2 wk who received an effective antimalarial within 1–2 d of the onset of fever. Here, the validity of caregiver recall for measuring the primary coverage indicators for malaria diagnosis and treatment of children <5 y old is assessed. Methods and Findings A cross-sectional study was conducted in five public clinics in Kaoma District, Western Provence, Zambia, to estimate the sensitivity, specificity, and accuracy of caregivers' recall of malaria testing, diagnosis, and treatment, compared to a gold standard of direct observation at the health clinics. Compared to the gold standard of clinic observation, for recall for children with fever in the past 2 wk, the sensitivity for recalling that a finger/heel stick was done was 61.9%, with a specificity of 90.0%. The sensitivity and specificity of caregivers' recalling a positive malaria test result were 62.4% and 90.7%, respectively. The sensitivity and specificity of recalling that the child was given a malaria diagnosis, irrespective of whether a laboratory test was actually done, were 76.8% and 75.9%, respectively. The sensitivity and specificity for recalling that an ACT was given were 81.0% and 91.5%, respectively. Conclusions Based on these findings, results from household surveys should continue to be used for ascertaining the coverage of children with a fever in the past 2 wk that received an ACT. However, as recall of a malaria diagnosis remains suboptimal, its use in defining malaria treatment coverage is not recommended. Please see later in the article for the Editors' Summary PMID:23667337
Esteghamati, Alireza; Ashraf, Haleh; Khalilzadeh, Omid; Zandieh, Ali; Nakhjavani, Manouchehr; Rashidi, Armin; Haghazali, Mehrdad; Asgari, Fereshteh
2010-04-07
We have recently determined the optimal cut-off of the homeostatic model assessment of insulin resistance for the diagnosis of insulin resistance (IR) and metabolic syndrome (MetS) in non-diabetic residents of Tehran, the capital of Iran. The aim of the present study is to establish the optimal cut-off at the national level in the Iranian population with and without diabetes. Data of the third National Surveillance of Risk Factors of Non-Communicable Diseases, available for 3,071 adult Iranian individuals aging 25-64 years were analyzed. MetS was defined according to the Adult Treatment Panel III (ATPIII) and International Diabetes Federation (IDF) criteria. HOMA-IR cut-offs from the 50th to the 95th percentile were calculated and sensitivity, specificity, and positive likelihood ratio for MetS diagnosis were determined. The receiver operating characteristic (ROC) curves of HOMA-IR for MetS diagnosis were depicted, and the optimal cut-offs were determined by two different methods: Youden index, and the shortest distance from the top left corner of the curve. The area under the curve (AUC) (95%CI) was 0.650 (0.631-0.670) for IDF-defined MetS and 0.683 (0.664-0.703) with the ATPIII definition. The optimal HOMA-IR cut-off for the diagnosis of IDF- and ATPIII-defined MetS in non-diabetic individuals was 1.775 (sensitivity: 57.3%, specificity: 65.3%, with ATPIII; sensitivity: 55.9%, specificity: 64.7%, with IDF). The optimal cut-offs in diabetic individuals were 3.875 (sensitivity: 49.7%, specificity: 69.6%) and 4.325 (sensitivity: 45.4%, specificity: 69.0%) for ATPIII- and IDF-defined MetS, respectively. We determined the optimal HOMA-IR cut-off points for the diagnosis of MetS in the Iranian population with and without diabetes.
Identifying substance misuse in primary care: TAPS Tool compared to the WHO ASSIST.
Schwartz, R P; McNeely, J; Wu, L T; Sharma, G; Wahle, A; Cushing, C; Nordeck, C D; Sharma, A; O'Grady, K E; Gryczynski, J; Mitchell, S G; Ali, R L; Marsden, J; Subramaniam, G A
2017-05-01
There is a need for screening and brief assessment instruments to identify primary care patients with substance use problems. This study's aim was to examine the performance of a two-step screening and brief assessment instrument, the TAPS Tool, compared to the WHO ASSIST. Two thousand adult primary care patients recruited from five primary care clinics in four Eastern US states completed the TAPS Tool followed by the ASSIST. The ability of the TAPS Tool to identify moderate- and high-risk use scores on the ASSIST was examined using sensitivity and specificity analyses. The interviewer and self-administered computer tablet versions of the TAPS Tool generated similar results. The interviewer-administered version (at cut-off of 2), had acceptable sensitivity and specificity for high-risk tobacco (0.90 and 0.77) and alcohol (0.87 and 0.80) use. For illicit drugs, sensitivities were >0.82 and specificities >0.92. The TAPS (at a cut-off of 1) had good sensitivity and specificity for moderate-risk tobacco use (0.83 and 0.97) and alcohol (0.83 and 0.74). Among illicit drugs, sensitivity was acceptable for moderate-risk of marijuana (0.71), while it was low for all other illicit drugs and non-medical use of prescription medications. Specificities were 0.97 or higher for all illicit drugs and prescription medications. The TAPS Tool identified adult primary care patients with high-risk ASSIST scores for all substances as well moderate-risk users of tobacco, alcohol, and marijuana, although it did not perform well in identifying patients with moderate-risk use of other drugs or non-medical use of prescription medications. The advantages of the TAPS Tool over the ASSIST are its more limited number of items and focus solely on substance use in the past 3months. Copyright © 2017 Elsevier Inc. All rights reserved.
Montoye, Alexander H K; Pivarnik, James M; Mudd, Lanay M; Biswas, Subir; Pfeiffer, Karin A
2016-01-01
Recent evidence suggests that physical activity (PA) and sedentary behavior (SB) exert independent effects on health. Therefore, measurement methods that can accurately assess both constructs are needed. To compare the accuracy of accelerometers placed on the hip, thigh, and wrists, coupled with machine learning models, for measurement of PA intensity category (SB, light-intensity PA [LPA], and moderate- to vigorous-intensity PA [MVPA]) and breaks in SB. Forty young adults (21 female; age 22.0 ± 4.2 years) participated in a 90-minute semi-structured protocol, performing 13 activities (three sedentary, 10 non-sedentary) for 3-10 minutes each. Participants chose activity order, duration, and intensity. Direct observation (DO) was used as a criterion measure of PA intensity category, and transitions from SB to a non-sedentary activity were breaks in SB. Participants wore four accelerometers (right hip, right thigh, and both wrists), and a machine learning model was created for each accelerometer to predict PA intensity category. Sensitivity and specificity for PA intensity category classification were calculated and compared across accelerometers using repeated measures analysis of variance, and the number of breaks in SB was compared using repeated measures analysis of variance. Sensitivity and specificity values for the thigh-worn accelerometer were higher than for wrist- or hip-worn accelerometers, > 99% for all PA intensity categories. Sensitivity and specificity for the hip-worn accelerometer were 87-95% and 93-97%. The left wrist-worn accelerometer had sensitivities and specificities of > 97% for SB and LPA and 91-95% for MVPA, whereas the right wrist-worn accelerometer had sensitivities and specificities of 93-99% for SB and LPA but 67-84% for MVPA. The thigh-worn accelerometer had high accuracy for breaks in SB; all other accelerometers overestimated breaks in SB. Coupled with machine learning modeling, the thigh-worn accelerometer should be considered when objectively assessing PA and SB.
Child–Pugh Versus MELD Score for the Assessment of Prognosis in Liver Cirrhosis
Peng, Ying; Qi, Xingshun; Guo, Xiaozhong
2016-01-01
Abstract Child–Pugh and MELD scores have been widely used for the assessment of prognosis in liver cirrhosis. A systematic review and meta-analysis aimed to compare the discriminative ability of Child–Pugh versus MELD score to assess the prognosis of cirrhotic patients. PubMed and EMBASE databases were searched. The statistical results were summarized from every individual study. The summary areas under receiver operating characteristic curves, sensitivities, specificities, positive and negative likelihood ratios, and diagnostic odds ratios were also calculated. Of the 1095 papers initially identified, 119 were eligible for the systematic review. Study population was heterogeneous among studies. They included 269 comparisons, of which 44 favored MELD score, 16 favored Child–Pugh score, 99 did not find any significant difference between them, and 110 did not report the statistical significance. Forty-two papers were further included in the meta-analysis. In patients with acute-on-chronic liver failure, Child–Pugh score had a higher sensitivity and a lower specificity than MELD score. In patients admitted to ICU, MELD score had a smaller negative likelihood ratio and a higher sensitivity than Child–Pugh score. In patients undergoing surgery, Child–Pugh score had a higher specificity than MELD score. In other subgroup analyses, Child–Pugh and MELD scores had statistically similar discriminative abilities or could not be compared due to the presence of significant diagnostic threshold effects. Although Child–Pugh and MELD scores had similar prognostic values in most of cases, their benefits might be heterogeneous in some specific conditions. The indications for Child–Pugh and MELD scores should be further identified. PMID:26937922
Kleindienst, Samantha J; Zapala, David A; Nielsen, Donald W; Griffith, James W; Rishiq, Dania; Lundy, Larry; Dhar, Sumitrajit
2017-10-01
The already large population of individuals with age- or noise-related hearing loss in the United States is increasing, yet hearing aids remain largely inaccessible. The recent decision by the US Food and Drug Administration to not enforce the medical examination prior to hearing aid fitting highlights the need to reengineer consumer protections when increasing accessibility. A self-administered tool to estimate ear disease risk would provide disease surveillance without posing an unreasonable barrier to hearing aid procurement. To develop and validate a consumer questionnaire for the self-assessment of risk for ear diseases associated with hearing loss. The questionnaire was developed using established methods including expert opinion to validate and create questions, and cognitive interviews to ensure that questions were clear to respondents. Exploratory structural equation modeling, logistic regression, and receiver operating characteristic curve analysis were used to determine sensitivity and specificity with blinded neurotologist opinion as the criterion for evaluation. Patients 40 to 80 years old with ear or hearing complaints necessitating a neurotologic examination and a control group of participants with a diagnosis of age- or noise-related hearing loss participated at the Departments of Otorhinolaryngology and Audiology of Mayo Clinic Florida. Sensitivity and specificity of the prototype questionnaire to identify individuals with targeted diseases. Of 307 participants (mean [SD] age, 62.9 [9.8] years; 148 [48%] female), 75% (n = 231) were enrolled with targeted disease(s) identified on neurotologic assessment and 25% (n = 76) with age- or noise-related hearing loss. Participants were randomly divided into a training sample (80% [n = 246; 185 with disease, 61 controls]) and a test sample (20% [n = 61; 46 with disease, 15 controls]). Using a simple scoring method, a sensitivity of 94% (95% CI, 89%-97%) and specificity of 61% (95% CI, 47%-73%) were established in the training sample. Applying this cutoff to the test sample resulted in 85% (95% CI, 71%-93%) sensitivity and 47% (95% CI, 22%-73%) specificity. This is the first self-assessment tool designed to assess an individual's risk for ear disease. Our preliminary results demonstrate a high sensitivity to disease detection. A further validated and refined version of this questionnaire may serve as an efficacious tool for improving access to hearing health care while minimizing the risk for missed ear diseases.
Verma, Nishant; Beretvas, S Natasha; Pascual, Belen; Masdeu, Joseph C; Markey, Mia K
2018-03-14
Combining optimized cognitive (Alzheimer's Disease Assessment Scale- Cognitive subscale, ADAS-Cog) and atrophy markers of Alzheimer's disease for tracking progression in clinical trials may provide greater sensitivity than currently used methods, which have yielded negative results in multiple recent trials. Furthermore, it is critical to clarify the relationship among the subcomponents yielded by cognitive and imaging testing, to address the symptomatic and anatomical variability of Alzheimer's disease. Using latent variable analysis, we thoroughly investigated the relationship between cognitive impairment, as assessed on the ADAS-Cog, and cerebral atrophy. A biomarker was developed for Alzheimer's clinical trials that combines cognitive and atrophy markers. Atrophy within specific brain regions was found to be closely related with impairment in cognitive domains of memory, language, and praxis. The proposed biomarker showed significantly better sensitivity in tracking progression of cognitive impairment than the ADAS-Cog in simulated trials and a real world problem. The biomarker also improved the selection of MCI patients (78.8±4.9% specificity at 80% sensitivity) that will evolve to Alzheimer's disease for clinical trials. The proposed biomarker provides a boost to the efficacy of clinical trials focused in the mild cognitive impairment (MCI) stage by significantly improving the sensitivity to detect treatment effects and improving the selection of MCI patients that will evolve to Alzheimer's disease. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Input-variable sensitivity assessment for sediment transport relations
NASA Astrophysics Data System (ADS)
Fernández, Roberto; Garcia, Marcelo H.
2017-09-01
A methodology to assess input-variable sensitivity for sediment transport relations is presented. The Mean Value First Order Second Moment Method (MVFOSM) is applied to two bed load transport equations showing that it may be used to rank all input variables in terms of how their specific variance affects the overall variance of the sediment transport estimation. In sites where data are scarce or nonexistent, the results obtained may be used to (i) determine what variables would have the largest impact when estimating sediment loads in the absence of field observations and (ii) design field campaigns to specifically measure those variables for which a given transport equation is most sensitive; in sites where data are readily available, the results would allow quantifying the effect that the variance associated with each input variable has on the variance of the sediment transport estimates. An application of the method to two transport relations using data from a tropical mountain river in Costa Rica is implemented to exemplify the potential of the method in places where input data are limited. Results are compared against Monte Carlo simulations to assess the reliability of the method and validate its results. For both of the sediment transport relations used in the sensitivity analysis, accurate knowledge of sediment size was found to have more impact on sediment transport predictions than precise knowledge of other input variables such as channel slope and flow discharge.
Sensitivity of Hyperdense Basilar Artery Sign on Non-Enhanced Computed Tomography
Ernst, Marielle; Romero, Javier M.; Buhk, Jan-Hendrik; Cheng, Bastian; Herrmann, Jochen; Fiehler, Jens; Groth, Michael
2015-01-01
Purpose The hyperdense basilar artery sign (HBAS) is an indicator of vessel occlusion on non contrast-enhanced computer tomography (NECT) in acute stroke patients. Since basilar artery occlusion (BAO) is associated with a high mortality and morbidity, its early detection is of great clinical value. We sought to analyze the influence of density measurement as well as a normalized ratio of Hounsfield unit/hematocrit (HU/Hct) ratio on the detection of BAO on NECT in patients with suspected BAO. Materials and Methods 102 patients with clinically suspected BAO were examined with NECT followed immediately by Multidetector computed tomography Angiography. Two observers independently analyzed the images regarding the presence or absence of HBAS on NECT and performed HU measurements in the basilar artery. Receiver operating characteristic curve analysis was performed to determine the optimal density threshold for BAO using attenuation measurements or HU/Hct ratio. Results Sensitivity of visual detection of the HBAS on NECT was relatively low 81% (95%-CI, 54–95%) while specificity was high 91% (95%-CI, 82–96%). The highest sensitivity was achieved by the combination of visual assessment and additional quantitative attenuation measurements applying a cut-off value of 46.5 HU with 94% sensitivity and 81% specificity for BAO. A HU/Hct ratio >1.32 revealed sensitivity of 88% (95%-CI, 60–98%) and specificity of 84% (95%-CI, 74–90%). Conclusion In patients with clinically suspected acute BAO the combination of visual assessment and additional attenuation measurement with a cut-off value of 46.5 HU is a reliable approach with high sensitivity in the detection of BAO on NECT. PMID:26479718
Gyawali, P; Sidhu, J P S; Ahmed, W; Jagals, P; Toze, S
2015-12-01
The risk of human hookworm infections from land application of wastewater matrices could be high in regions with high hookworm prevalence. A rapid, sensitive and specific hookworm detection method from wastewater matrices is required in order to assess human health risks. Currently available methods used to identify hookworm ova to the species level are time consuming and lack accuracy. In this study, a real-time PCR method was developed for the rapid, sensitive and specific detection of canine hookworm (Ancylostoma caninum) ova from wastewater matrices. A. caninum was chosen because of its morphological similarity to the human hookworm (Ancylostoma duodenale and Necator americanus). The newly developed PCR method has high detection sensitivity with the ability to detect less than one A. caninum ova from 1 L of secondary treated wastewater at the mean threshold cycle (CT) values ranging from 30.1 to 34.3. The method is also able to detect four A. caninum ova from 1 L of raw wastewater and from ∼4 g of treated sludge with mean CT values ranging from 35.6 to 39.8 and 39.8 to 39.9, respectively. The better detection sensitivity obtained for secondary treated wastewater compared to raw wastewater and sludge samples could be attributed to sample turbidity. The proposed method appears to be rapid, sensitive and specific compared to traditional methods and has potential to aid in the public health risk assessment associated with land application of wastewater matrices. Furthermore, the method can be adapted to detect other helminth ova of interest from wastewater matrices. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Sensitivity of Gram stain in the diagnosis of urethritis in men.
Orellana, M Angeles; Gómez-Lus, M Luisa; Lora, David
2012-06-01
Acute urethritis is among the most common types of sexually transmitted diseases in men. The diagnosis usually requires microscopic evidence of urethritis, but sometimes urethral pathogens are detected in asymptomatic men without such evidence. The aims of this study were to assess the sensitivity of Gram stain in men with urethral symptoms and to relate it to the microorganisms isolated. Between January 2006 and December 2007, 491 urethral samples were analysed. The authors assessed the presence of leukocytes by Gram stain and tested specifically for Chlamydia trachomatis, Ureaplasma urealyticum, Mycoplasma hominis and Trichomonas vaginalis, as well as analysing the results of conventional culture. The percentages of positive samples as a function of Gram category were two or less polymorphonuclear leukocytes (PMNLs)/high-power field (HPF) 25% (92/364), three to four PMNLs/HPF 32% (18/57) and five or more PMNLs/HPF 54% (38/70). Classing samples with more than two PMNLs/HPF as positive, the sensitivity, specificity and positive likelihood ratio for Gram stain were 38% (95% CI 30 to 46), 79% (95% CI 75 to 84) and 1.8 (95% CI 1.4 to 2.4), respectively. On the other hand, taking as positive five or more PMNLs/HPF, the sensitivity, specificity and positive likelihood ratio for Gram stain were 26% (95% CI 18 to 33), 91% (95% CI 87 to 94) and 2.7 (95% CI 1.8 to 4.2), respectively. The sensitivity of Gram stain to Neisseria gonorrhoeae, Chlamydia trachomatis and Ureaplasma urealyticum were 80% (95% CI 64 to 96), 23% (95% CI 8 to 39) and 11% (95% CI 2 to 20), respectively. The low sensitivity of Gram stain means that negative results do not exclude the presence of urethritis in symptomatic patients.
Nikolopoulou, Eleni; Lorusso, Massimo; Micelli Ferrari, Luisa; Cicinelli, Maria Vittoria; Bandello, Francesco; Querques, Giuseppe; Micelli Ferrari, Tommaso
2018-01-01
Optical coherence tomography angiography (OCTA) could be a valid tool to detect choroidal neovascularization (CNV) in neovascular age-related macular degeneration (nAMD), allowing the analysis of the type, the morphology, and the extension of CNV in most of the cases. To determine the sensitivity and specificity of OCTA in detecting CNV secondary to nAMD, compared to fluorescein angiography (FA) and indocyanine green angiography (ICGA). Prospective observational study. Patients with suspected nAMD were recruited between May and December 2016. Patients underwent FA, ICGA, spectral domain OCT, and OCTA (AngioVue, Optovue, Inc.). Sensitivity and specificity of FA, with or without ICGA, were assessed and compared with OCTA. Seventy eyes of 70 consecutive patients were included: 32 eyes (45.7%) with type I CNV, 8 eyes (11.4%) with type II CNV, 4 eyes (5.7%) with type III CNV, 6 eyes (8.6%) with mixed type I and type II CNV, and 20 eyes (28.6%) with no CNV. Sensitivity of OCTA was 88% and specificity was 90%. Concordance between FA/ICGA and OCTA was very good (0,91; range 0,81-1,00). OCTA showed high sensitivity and specificity for detection of CNV. Concordance between OCTA and gold-standard dye-based techniques was excellent. OCTA may represent a first-line noninvasive method for the diagnosis of nAMD.
Rapid antigen detection test for group A streptococcus in children with pharyngitis.
Cohen, Jérémie F; Bertille, Nathalie; Cohen, Robert; Chalumeau, Martin
2016-07-04
Group A streptococcus (GAS) accounts for 20% to 40% of cases of pharyngitis in children; the remaining cases are caused by viruses. Compared with throat culture, rapid antigen detection tests (RADTs) offer diagnosis at the point of care (within five to 10 minutes). To determine the diagnostic accuracy of RADTs for diagnosing GAS in children with pharyngitis. To assess the relative diagnostic accuracy of the two major types of RADTs (enzyme immunoassays (EIA) and optical immunoassays (OIA)) by indirect and direct comparison. We searched CENTRAL, MEDLINE, EMBASE, Web of Science, CDSR, DARE, MEDION and TRIP (January 1980 to July 2015). We also conducted related citations tracking via PubMed, handsearched reference lists of included studies and relevant review articles, and screened all articles citing included studies via Google Scholar. We included studies that compared RADT for GAS pharyngitis with throat culture on a blood agar plate in a microbiology laboratory in children seen in ambulatory care. Two review authors independently screened titles and abstracts for relevance, assessed full texts for inclusion, and carried out data extraction and quality assessment using the QUADAS-2 tool. We used bivariate meta-analysis to estimate summary sensitivity and specificity, and to investigate heterogeneity across studies. We compared the accuracy of EIA and OIA tests using indirect and direct evidence. We included 98 unique studies in the review (116 test evaluations; 101,121 participants). The overall methodological quality of included studies was poor, mainly because many studies were at high risk of bias regarding patient selection and the reference standard used (in 73% and 43% of test evaluations, respectively). In studies in which all participants underwent both RADT and throat culture (105 test evaluations; 58,244 participants; median prevalence of participants with GAS was 29.5%), RADT had a summary sensitivity of 85.6%; 95% confidence interval (CI) 83.3 to 87.6 and a summary specificity of 95.4%; 95% CI 94.5 to 96.2. There was substantial heterogeneity in sensitivity across studies; specificity was more stable. There was no evidence of a trade-off between sensitivity and specificity. Heterogeneity in accuracy was not explained by study-level characteristics such as whether an enrichment broth was used before plating, mean age and clinical severity of participants, and GAS prevalence. The sensitivity of EIA and OIA tests was comparable (summary sensitivity 85.4% versus 86.2%). Sensitivity analyses showed that summary estimates of sensitivity and specificity were stable in low risk of bias studies. In a population of 1000 children with a GAS prevalence of 30%, 43 patients with GAS will be missed. Whether or not RADT can be used as a stand-alone test to rule out GAS will depend mainly on the epidemiological context. The sensitivity of EIA and OIA tests seems comparable. RADT specificity is sufficiently high to ensure against unnecessary use of antibiotics. Based on these results, we would expect that amongst 100 children with strep throat, 86 would be correctly detected with the rapid test while 14 would be missed and not receive antibiotic treatment.
Goodyear-Smith, Felicity; Arroll, Bruce; Coupe, Nicole
2009-01-01
PURPOSE The short, validated, self-administered, Case-finding and Help Assessment Tool (CHAT) for lifestyle and mental health assessment of adult patients in primary health care addresses inactivity, tobacco use, alcohol and other drug misuse, problem gambling, depression, anxiety and stress, abuse, and anger problems. For each issue patients are asked whether they would like help, either during the consultation or at a later date. This study aims to assess the value of the help question. METHODS Validation of the CHAT was conducted according to the STAndards for Reporting of Diagnostic accuracy studies statement for diagnostic tests. The setting was Auckland primary care practices with populations ranging from socioeconomically advantaged to deprived. Participants were 755 consecutive primary care patients who completed the CHAT plus the help question and reference standards. Sensitivity, specificity, and likelihood ratios with and without the addition of help the question were calculated. RESULTS Sensitivity ranged from 80% to 98% for the more-common conditions (depression, nicotine dependency, anxiety, problematic drinking). For each condition, specificity increased with the addition of the help question: depression increased from 73% to 98%; anxiety 77% to 99%; drinking 85% to 99%; verbal anger 92% to 99%; verbal abuse 97% to 99%; problematic drinking and gambling 98% to 99%. CONCLUSIONS The help question increased specificity without compromising sensitivity and reduced false positives, thereby increasing the positive predictive value. It allowed patients with comorbidities to prioritize issues they wished to address, indicate their readiness to change, promote self-determination, and give the clinician an indication of which topics to pursue. PMID:19433841
de Olim, Carlo; Bégin, Denis; Boulet, Louis-Philippe; Cartier, André; Gérin, Michel; Lemière, Catherine
2015-01-01
BACKGROUND: Specific inhalation challenges (SIC) enable the identification of the agent responsible of occupational asthma (OA). A clinician may fail to identify a specific agent in the workplace, which may potentially lead to a misdiagnosis. The expert assessment method performed by an occupational hygienist has been used to evaluate occupational exposures in epidemiological studies. OBJECTIVE: The broad aim of the present study was to evaluate the contribution of an expert assessment performed by an occupational hygienist to the diagnosis of OA. The specific aim was to compare work-place exposures identified by an occupational hygienist and by chest physicians in subjects with positive SICs and subjects with asthma, but with a negative SIC. METHODS: SICs were performed in 120 cases: 67 were positive and 53 were negative. A clinician assessed occupational exposures to sensitizers during a routine clinical evaluation preceding the performance of the SIC. An expert assessment of occupational exposures was performed by an occupational hygienist blind to the result of the SIC. RESULTS: The occupational hygienist identified the causal agent in 96.7% of the 61 cases of positive SIC. In 33 (62.3%) cases of negative SICs, the occupational hygienist identified ≥1 sensitizing agent(s) that had not been identified by the clinician. CONCLUSION: The hygienist identified the causal agent in almost all subjects with OA. In contrast, the clinician failed to identify potential exposures to sensitizers in >60% of the negative SIC subjects, which may have resulted in some subjects being misdiagnosed as not having OA. PMID:26422401
Non-Invasive Detection of Risk for Emotion Provoked Myocardial Ischemia
Burg, Matthew M.; Graeber, Brendon; Vashist, Aseem; Collins, Dorothea; Earley, Christine; Liu, Joyce; Lampert, Rachel; Soufer, Robert
2009-01-01
Objectives To test an easily administered, noninvasive technology to identify vulnerability to mental stress ischemia. Background Myocardial ischemia provoked by emotional stress (MSI) in patients with stable coronary artery disease (CAD) predicts major adverse cardiac events. A clinically useful tool to risk stratify patients on this factor is not available. Methods Patients with documented CAD (n=68) underwent single photon emission computed tomography (SPECT) myocardial perfusion imaging concurrent with pulse wave amplitude assessment by peripheral arterial tonometry (PAT) during a mental stress protocol of sequential rest and anger stress periods. Heart rate and blood pressure were assessed, and blood was drawn for catecholamine assay, during rest and stress. MSI was defined by the presence of a new perfusion defect during anger stress (n=26) and the ratio of stress to rest PAT response was calculated. Results Patients with MSI had a significantly lower PAT ratio than those without MSI (0.76 ± 0.04 vs. 0.91 ± 0.05, p=0.03). An ROC curve for optimum sensitivity/specificity of PAT ratio as an index of MSI produced a sensitivity of 0.62 and a specificity of 0.63. Among patients taking angiotensin converter enzyme (ACE) inhibitors, the sensitivity and specificity of the test increased to 0.86 and 0.73 (respectively); 90% of patients without MSI were correctly identified. Conclusions PAT in concert with ACE inhibition may provide a useful approach to assess risk for MSI. Future studies should help determine how best to utilize this approach for risk assessment in the clinical setting. PMID:18941131
Natsch, Andreas; Emter, Roger; Haupt, Tina; Ellis, Graham
2018-06-01
Cosmetic regulations prohibit animal testing for the purpose of safety assessment and recent REACH guidance states that the local lymph node assay (LLNA) in mice shall only be conducted if in vitro data cannot give sufficient information for classification and labelling. However, Quantitative Risk Assessment (QRA) for fragrance ingredients requires a NESIL, a dose not expected to cause induction of skin sensitization in humans. In absence of human data, this is derived from the LLNA and it remains a key challenge for risk assessors to derive this value from non-animal data. Here we present a workflow using structural information, reactivity data and KeratinoSens results to predict a LLNA result as a point of departure. Specific additional tests (metabolic activation, complementary reactivity tests) are applied in selected cases depending on the chemical domain of a molecule. Finally, in vitro and in vivo data on close analogues are used to estimate uncertainty of the prediction in the specific chemical domain. This approach was applied to three molecules which were subsequently tested in the LLNA and 22 molecules with available and sometimes discordant human and LLNA data. Four additional case studies illustrate how this approach is being applied to recently developed molecules in the absence of animal data. Estimation of uncertainty and how this can be applied to determine a final NESIL for risk assessment is discussed. We conclude that, in the data-rich domain of fragrance ingredients, sensitization risk assessment without animal testing is possible in most cases by this integrated approach.
Beauchet, O; Noublanche, F; Simon, R; Sekhon, H; Chabot, J; Levinoff, E J; Kabeshova, A; Launay, C P
2018-01-01
Identification of the risk of falls is important among older inpatients. This study aims to examine performance criteria (i.e.; sensitivity, specificity, positive predictive value, negative predictive value and accuracy) for fall prediction resulting from a nurse assessment and an artificial neural networks (ANNs) analysis in older inpatients hospitalized in acute care medical wards. A total of 848 older inpatients (mean age, 83.0±7.2 years; 41.8% female) admitted to acute care medical wards in Angers University hospital (France) were included in this study using an observational prospective cohort design. Within 24 hours after admission of older inpatients, nurses performed a bedside clinical assessment. Participants were separated into non-fallers and fallers (i.e.; ≥1 fall during hospitalization stay). The analysis was conducted using three feed forward ANNs (multilayer perceptron [MLP], averaged neural network, and neuroevolution of augmenting topologies [NEAT]). Seventy-three (8.6%) participants fell at least once during their hospital stay. ANNs showed a high specificity, regardless of which ANN was used, and the highest value reported was with MLP (99.8%). In contrast, sensitivity was lower, with values ranging between 98.4 to 14.8%. MLP had the highest accuracy (99.7). Performance criteria for fall prediction resulting from a bedside nursing assessment and an ANNs analysis was associated with a high specificity but a low sensitivity, suggesting that this combined approach should be used more as a diagnostic test than a screening test when considering older inpatients in acute care medical ward.
Quality control in molecular immunohistochemistry
2008-01-01
Immunoperoxidase histochemistry is a widespread method of assessing expression of biomolecules in tissue samples. Accurate assessment of the expression levels of genes is critical for the management of disease, particularly as therapy targeted to specific molecules becomes more widespread. Determining the quality of preservation of macromolecules in tissue is important to avoid false negative and false positive results. In this review we discuss (1) issues of sensitivity (false negativity) and specificity (false positivity) of immunohistochemical stains, (2) approaches to better understanding differences in immunostains done by different laboratories (including the recently proposed MISFISHIE specification for tissue localization studies), and (3) approaches to assessing the quality of preservation of macromolecules in tissue, particularly in small biopsy samples. PMID:18648842
Sensitivity and specificity of presumptive tests for blood, saliva and semen.
Vennemann, Marielle; Scott, Georgina; Curran, Lynn; Bittner, Felix; Tobe, Shanan S
2014-03-01
Despite their wide use, the limits of presumptive tests can be poorly understood. The aim of this study was to investigate the specificity and sensitivity of conventional, as well as innovative, presumptive tests for blood, semen and saliva. We investigated Kastle-Meyer (KM) and leucomalachite green (LMG) tests for blood with regard to their sensitivity and specificity in the presence of oxidizing (hypochlorite) and anti-oxidizing (ascorbic acid) agents. The suitability and specificity of the red starch paper (RSP) test for saliva was assessed. Finally, the inhibitory effect of detergent on the acid phosphatase (AP) test for semen was investigated along with possible cross reactions to tea stains. Our results confirm previous findings of higher sensitivity and specificity of the KM test compared to LMG test for blood. Contrary to previous studies, no statistically significant difference was observed in the sensitivity of the tests between dry and wet stains. The novel RSP test was found to successfully detect saliva. We demonstrated that acid phosphatase (AP) testing for semen is possible on used RSP. A common multipurpose detergent had an inhibitory effect on AP tests. False positive results were obtained from tea stains. Testing different sorts of tea (black, green and herbal teas) revealed that only Camellia varieties produce positive result with the AP test, due to AP being present in the plants. From our results we conclude that specific knowledge of each test, including substances that may affect the test outcome, is imperative to ensure correct interpretation of presumptive test results.
Madžar, Zrinko; Kopljar, Mario; Madžar, Tomislav; Mesić, Marko; Mužina Mišić, Dubravka; Čiček, Slaven; Zovak, Mario
2016-12-01
The aim of the study was to assess diagnostic accuracy (sensitivity and specificity) of Fenyö-Lindberg and Teicher scores for distinguishing patients that need immediate surgical treatment from the others, in a female population from an urban setting. The study prospectively included 130 female patients admitted to the emergency department with abdominal pain indicating acute appendicitis. The scores and parameters of validity were calculated and compared to definitive diagnosis. For Fenyö-Lindberg score of -17 or less, 84.5% sensitivity, 55.6% specificity, 87.9% positive predictive value (PPV) and 48.4% negative predictive value (NPV) were recorded. For cut-off value greater or equal to -2, there was 59.2% sensitivity, 77.8% specificity, 91% PPV and 33.3% NPV. The Receiver Operating Characteristic (ROC) curve analysis of Fenyö-Lindberg score showed that the best single cut-off value for discriminating acute appendicitis in the study population was -15. For Teicher score, values greater than -3 yielded 89.3% sensitivity and 22.2% specificity, 81.4% PPV and 35.3% NPV. In conclusion, Fenyö-Lindberg score could be used as an additional tool to exclude appendicitis and avoid unnecessary appendectomies. Teicher score may help in recognizing patients with appendicitis. None of the two scores can indicate or decline appendectomy in all cases. Scoring systems may be useful for pointing to important clinical signs and symptoms in specific subpopulations.
van Loon, Johannes P A M; Van Dierendonck, Machteld C
2015-12-01
Although recognition of equine pain has been studied extensively over the past decades there is still need for improvement in objective identification of pain in horses with acute colic. This study describes scale construction and clinical applicability of the Equine Utrecht University Scale for Composite Pain Assessment (EQUUS-COMPASS) and the Equine Utrecht University Scale for Facial Assessment of Pain (EQUUS-FAP) in horses with acute colic. A cohort follow-up study was performed using 50 adult horses (n = 25 with acute colic, n = 25 controls). Composite pain scores were assessed by direct observations, Visual Analog Scale (VAS) scores were assessed from video clips. Colic patients were assessed at arrival, and on the first and second mornings after arrival. Both the EQUUS-COMPASS and EQUUS-FAP scores showed high inter-observer reliability (ICC = 0.98 for EQUUS-COMPASS, ICC = 0.93 for EQUUS-FAP, P <0.001), while a moderate inter-observer reliability for the VAS scores was found (ICC = 0.63, P <0.001). The cut-off value for differentiation between healthy and colic horses for the EQUUS-COMPASS was 5, and for differentiation between conservatively treated and surgically treated or euthanased patients it was 11. For the EQUUS-FAP, cut-off values were 4 and 6, respectively. Internal sensitivity and specificity were good for both EQUUS-COMPASS (sensitivity 95.8%, specificity 84.0%) and EQUUS-FAP (sensitivity 87.5%, specificity 88.0%). The use of the EQUUS-COMPASS and EQUUS-FAP enabled repeated and objective scoring of pain in horses with acute colic. A follow-up study with new patients and control animals will be performed to further validate the constructed scales that are described in this study. Copyright © 2015 Elsevier Ltd. All rights reserved.
The First Time Ever I Saw Your Feet: Inversion Effect in Newborns' Sensitivity to Biological Motion
ERIC Educational Resources Information Center
Bardi, Lara; Regolin, Lucia; Simion, Francesca
2014-01-01
Inversion effect in biological motion perception has been recently attributed to an innate sensitivity of the visual system to the gravity-dependent dynamic of the motion. However, the specific cues that determine the inversion effect in naïve subjects were never investigated. In the present study, we have assessed the contribution of the local…
Santamaría, Erika; Ponce, Nubia; Puerta, Concepción; Ferro, Cristina
2005-06-01
The applicability of the polymerase chain reaction (PCR) was evaluated for the detection and identification of parasites in sand fly vectors and thereby precluding the necessity of dissecting them. DNA was extracted from individual, laboratory infected sand flies, and subjected to PCR amplification using specific B1 and B2 primers for parasites of the Leishmania (Viannia) subgenus. The sensitivity and specificity of the PCR primers were defined by means of serial dilutions of a Leishmania culture. Pooled samples of 1 to 5 sandflies were examined in association with the parasite dilutions to determine the point at which sensitivity became reduced. Experimentally infected sand flies were used to compare the sensitivity of the PCR with sand fly dissection and searching for flagellated parasites by microscopic examination. As few as a single parasite was detected, and the sensitivity remained unaltered up to 3 female sand flies per pool. Detection rates were 33% for the traditional technique and 33.3% for PCR. The B1 and B2 primers were confirmed as specific for Leishmania (Viannia) parasites. The demonstrably high sensitivity and specificity of PCR warrant the use of PCR in assessing natural infection rates of Leishmania (Viannia) in field populations of sand fly vectors.
Choe, Young June; Hu, Jae Kyung; Song, Kyung Min; Cho, Heeyeon; Yoon, Hee Sook; Kim, Seung Tae; Lee, Han Jung; Kim, Kisoon; Bae, Geun-Ryang; Lee, Jong-Koo
2012-01-01
In this study, we have described the clinical characteristics of vaccine-modified measles to assess the performance of an expanded case definition in a school outbreak that occurred in 2010. The sensitivity, specificity, and the positive and negative predictive values were evaluated. Among 74 cases of vaccine-modified measles, 47 (64%) met the original case definition. Fever and rash were observed in 73% (54/74); fever was the most common (96%, 71/74) presenting symptom, and rash was noted in 77% (57/74) of the cases. The original case definition showed an overall sensitivity of 63.5% and a specificity of 100.0%. The expanded case definition combining fever and rash showed a higher sensitivity (72.9%) but a lower specificity (88.2%) than the original. The presence of fever and one or more of cough, coryza, or conjunctivitis scored the highest sensitivity among the combinations of signs and symptoms (77.0%), but scored the lowest specificity (52.9%). The expanded case definition was sensitive in identifying suspected cases of vaccine-modified measles. We suggest using this expanded definition for outbreak investigation in a closed community, and consider further discussions on expanding the case definition of measles for routine surveillance in South Korea.
Khanna, Ashish; Khanna, Menka; Gill, Karamjit Singh
2015-11-01
Typhoid fever remains a significant health problem in endemic countries like India. Various serological tests for the diagnosis of typhoid fever are available commercially. We assessed the usefulness of rapid test based on magnetic particle separation to detect Immunoglobulin against Salmonella typhi O9 lipopolysaccharide. Aim of this study was to compare the sensitivity and specificity of widal test, typhidot and tubex TF test for the diagnosis of typhoid fever in an endemic country like India. Serum samples collected from 50 patients of typhoid fever, 50 patients of non typhoid fever and 100 normal healthy individuals residing in Amritsar were subjected to widal test, typhidot test and tubex TF test as per manufacturer's instructions. Data collected was assessed to find sensitivity and specificity of these tests in an endemic area. Significant widal test results were found positive in 68% of patients of typhoid fever and only 4% of non typhoid fever patients. Typhidot (IgM or IgG) was positive in 72% of typhoid fever patients and 10% and 6% in non typhoid fever and normal healthy individuals respectively. Tubex TF showed higher sensitivity of 76% and specificity of 96-99% which was higher than typhidot and comparable to widal test. This was the first evaluation of rapid tubex TF test in northern India. In countries which can afford high cost of test, tubex TF should be recommended for the diagnosis in acute stage of the disease in clinical setting. However, there is urgent need for a highly specific and sensitive test for the diagnosis of typhoid fever in clinical settings in endemic areas.
Federico, Angela; Trentin, Michela; Zanette, Giampietro; Mapelli, Daniela; Picelli, Alessandro; Smania, Nicola; Tinazzi, Michele; Tamburin, Stefano
2017-08-01
Mild cognitive impairment (MCI) is common in patients with Parkinson's disease (PD) and should be recognized early because it represents a predictor of PD-related dementia and worse disease course. Diagnostic criteria for PD-related MCI (PD-MCI) have recently been defined by a Movement Disorders Society (MDS) task force. The present study explored which neuropsychological tests perform best for a level II (i.e., comprehensive neuropsychological assessment) diagnosis of PD-MCI according to the MDS task force criteria in Italian-speaking PD patients. To this aim, we assessed a comprehensive 23-item neuropsychological battery, derived the best-performing 10-test battery (i.e., two tests per domain for each of the five cognitive domains), and explored its accuracy for diagnosing PD-MCI in comparison to the full battery in a group of PD patients. A secondary aim was to explore the role of this battery for subtyping PD-MCI according to single-domain vs. multiple-domain involvement. The 10-test battery showed 73% sensitivity and 100% specificity for diagnosing PD-MCI, and 69% sensitivity and 100% specificity for PD-MCI subtyping. In patients older than 70 years, we derived a slightly different 10-test battery with 84% sensitivity and 100% specificity for PD-MCI diagnosis, and 86% sensitivity and 100% specificity for PD-MCI subtyping. These 10-item neuropsychological batteries might represent a good trade-off between diagnostic accuracy and time of application, and their role in PD-MCI diagnosis and subtyping should be further explored in future prospective studies.
Gui, Xuwei; Xiao, Heping
2014-01-01
This systematic review and meta-analysis was performed to determine accuracy and usefulness of adenosine deaminase (ADA) in diagnosis of tuberculosis pleurisy. Medline, Google scholar and Web of Science databases were searched to identify related studies until 2014. Two reviewers independently assessed quality of studies included according to standard Quality Assessment of Diagnosis Accuracy Studies (QUADAS) criteria. The sensitivity, specificity, diagnostic odds ratio and other parameters of ADA in diagnosis of tuberculosis pleurisy were analyzed with Meta-DiSC1.4 software, and pooled using the random effects model. Twelve studies including 865 tuberculosis pleurisy patients and 1379 non-tuberculosis pleurisy subjects were identified from 110 studies for this meta-analysis. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnosis odds ratio (DOR) of ADA in the diagnosis of tuberculosis pleurisy were 45.25 (95% CI 27.63-74.08), 0.86 (95% CI 0.84-0.88), 0.88 (95% CI 0.86-0.90), 6.32 (95% CI 4.83-8.26) and 0.15 (95% 0.11-0.22), respectively. The area under the summary receiver operating characteristic curve (SROC) was 0.9340. Our results demonstrate that the sensitivity and specificity of ADA are high in the diagnosis of tuberculosis pleurisy especially when ADA≥50 (U/L). Thus, ADA is a relatively sensitive and specific marker for tuberculosis pleurisy diagnosis. However, it is cautious to apply these results due to the heterogeneity in study design of these studies. Further studies are required to confirm the optimal cut-off value of ADA.
Lepidoglyphus destructor acarus in the urban house environment.
Juliá, J C; Martorell, A; Ventas, P; Cerdá, J C; Torró, I; Carreira, J; Guinot, E; Sanz, J; Alvarez, V
1995-01-01
To assess the presence of Lepidoglyphus destructor in the household environment of sensitized children living in an urban environment, samples of house dust were collected at the homes where two groups of patients were living, as well as in two bakeries in the city of Valencia, which were taken as a reference. Patients were divided into two groups. Group A included atopic children suffering from rhinitis and/or asthma, who were sensitized to L. destructor, as proven by prick test and specific IgE (CAP). Group B included children with the same features as those included in Group A, who were sensitized to Dermatophagoides pteronyssinus, with prick and CAP tests showing no significant sensitization to L. destructor. The samples of dust were analyzed, and the amounts of Der p I, Der f I, Der II and Lep d I per gram of dust were assessed through a solid-phase ELISA with monoclonal antibodies. In Group A, all patients but two showed a sensitization to D. pteronyssinus by prick test and serum IgE. At the homes of the patients from both groups, significant levels of Dermatophagoides were found. In Group A, only three houses showed levels of L. destructor which were comparable to those found in bakeries. Lep d I was not found in the houses of Group B patients. This means that a sensitization to L. destructor, as assessed with full extracts, is not always an indicator of its presence at the patient's house environment; it may rather refer to cross-reactivity to Dermatophagoides. Thus, availability of the main antigen Lep d I seems necessary to increase the specificity of the allergologic study.
Senthilkumar, T M A; Subathra, M; Ramadass, P; Ramaswamy, V
2010-02-01
The efficacy of a recombinant leptospiral outer membrane protein LipL41 as an antigen for conducting IgG-Enzyme linked immunosorbent assay (ELISA) and latex agglutination test (LAT) for serodiagnosis of bovine leptospirosis was evaluated. The recombinant LipL41 antigen developed and used for detecting the antibodies was specific in detection of the pathogenic serovars of Leptospira, as the expression of the LipL41 antigen is restricted only to pathogenic leptospires. A total of 430 bovine serum samples were subjected to IgG-ELISA and LAT, and the sensitivity and specificity were assessed in comparison with microscopic agglutination test (MAT). The sensitivity and specificity of IgG-ELISA and LAT were 86.84% and 93.16%, and 95.42% and 98.33% respectively. Both the tests are found to be sensitive, specific and concurred with the standard MAT. The study concluded that the rLipL41 protein could be used as a potential diagnostic antigen in different assay formats for bovine leptospirosis.
Satoh, Masayuki; Mori, Chika; Matsuda, Kana; Ueda, Yukito; Tabei, Ken-ichi; Kida, Hirotaka; Tomimoto, Hidekazu
2016-01-01
Background/Aims Constructional apraxia (CA) is usually diagnosed by having patients draw figures; however, the reported assessments only evaluate the drawn figure. We designed a new assessment battery for CA (the Mie Constructional Apraxia Scale, MCAS) which includes both the shape and drawing process, and investigated its utility against other assessment methods. Methods We designed the MCAS, and evaluated inter- and intrarater reliability. We also investigated the sensitivity, specificity, and positive and negative predictive values in dementia patients, and compared MCAS assessment with other reported batteries in the same subjects. Results Moderate interrater reliability was shown for speech therapists with limited experience. Moderate to substantial intrarater reliability was shown several weeks after initial assessment. When cutoff scores and times were set at 2/3 points and 39/40 s, sensitivity and specificity were 77.1 and 70.4%, respectively, with positive and negative predictive values of 80.0 and 66.7%, respectively. Dementia patients had significantly worse scores and times for Necker cube drawing than an elderly control group on the MCAS, and on other assessments. Conclusions We conclude that the MCAS, which includes both the assessment of the drawn Necker cube shape and the drawing process, is useful for detecting even mild CA. PMID:27790241
Parental questionnaire as a screening instrument for motor function at age five.
Nordbye-Nielsen, Kirsten; Kesmodel, Ulrik Schiøler
2014-12-01
No standardised method is used to determine motor function in children in general practice in Denmark. Our aim was to evaluate the correlation between a parental questionnaire assessing motor function at the age of five years and the clinical test Movement Assessment Battery for Children (M-ABC), and to assess whether one or more questions could be used to screen for motor problems at the age of five years. This study was based on a parental questionnaire containing ten questions. The M-ABC was used as the gold standard. n = 755 children. The Mann-Whitney rank sum test, Pearson's χ(2)-test, logistic regression analyses and sensitivity and specificity were used to assess the correlation between the questionnaire and the M-ABC test. The best screening tool was six questions in combination: sensitivity 39.8%, specificity 87.1%. Asking if a health professional ever expressed concern about the childs motor development had a sensitivity of 17.0% and a specificity of 93.9%. A parental questionnaire used as a screening instrument to identify children with motor problems has a reasonable specificity, but a low sensitivity. The six questions can be used to identify children who do not have motor function difficulties with a relatively high certainty, and it can fairly well identify children with motor function problems. This study was primarily supported by the Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA. Additional support was obtained from The Danish Health and Medicines Authority, the Lundbeck Foundation, Ludvig & Daara Elsass Foundation, the Augustinus Foundation, and Aase & Ejnar Danielsens Foundation. The Danish National Research Foundation has established the Danish Epidemiology Science Centre that initiated and created the Danish National Birth Cohort. The cohort is furthermore a result of a major grant from this Foundation. Additional support for the Danish National Birth Cohort is obtained from the Pharmacy Foundation, the Egmont Foundation, the March of Dimes Birth Defects Foundation, the Augustinus Foundation and the Health Foundation. Approved by the Danish National Birth Cohort (DNBC) Board of Directors, the DNBC Steering Committee, the Regional Ethics Committee, the Danish Data Protection Agency and the CDC Institutional Review Board.
Wang, Xiao-ting; Liu, Da-wei; Zhang, Hong-min; He, Huai-wu; Liu, Ye; Chai, Wen-zhao; Du, Wei
2012-12-01
To investigate the effect of the bedside lung ultrasound in emergency(BLUE)-plus lung ultrasound protocol on lung consolidation and atelectasis of critical patients. All patients who need to receive mechanical ventilation for more than 48 hours in ICU from June 2010 to December 2011 in Peking Union Medical College Hospital were included in the study. BLUE-plus and BLUE lung ultrasound, bedside X-ray, lung CT examination were performed on all patients at the same time. The condition of lung consolidation and atelectasis discovered by BLUE-plus lung ultrasound protocol was recorded and compared with bedside X-ray or lung CT. The difference in assessment of lung consolidation and atelectasis between BLUE-plus lung ultrasound protocol and BLUE protocol was compared. A total of 78 patients were finally enrolled in the study. The lung CT found 70 cases (89.74%) had different degrees of lung consolidation and atelectasis. The sensitivity, specificity and diagnostic accuracy of lung consolidation and atelectasis by the bedside chest X-ray were 31.29%, 75.00% and 38.46%, respectively. BLUE-plus lung ultrasound protocol found 68 cases with lung consolidation and atelectasis, and its sensitivity, specificity, and diagnostic accuracy were 95.71%, 87.50% and 94.87%, respectively, which were significantly higher than those of lung CT. BLUE protocol found 48 cases of lung consolidation and atelectasis, and its sensitivity, specificity, and diagnostic accuracy were 65.71%, 75.00% and 66.67%, respectively. The position of lung consolidation and atelectasis which hadn't been found by BLUE protocol was mainly proved to be located in the basement of lung by lung CT. The incidence of lung consolidation and atelectasis in critical patients who received mechanical ventilation is high. The BLUE-plus lung ultrasound protocol has a relatively higher sensitivity, specificity and diagnostic accuracy for consolidation and atelectasis, which can find majority of consolidation and atelectasis. As BLUE-plus lung ultrasound is a bedside noninvasive method allowing immediate assessment of most lung consolidation and atelectasis, it will be likely the alternative of the CT and play a key role in assessment of lung consolidation and atelectasis.
Nishii, Takashi; Tanaka, Hisashi; Nakanishi, Katsuyuki; Sugano, Nobuhiko; Miki, Hidenobu; Yoshikawa, Hideki
2005-08-01
Our objective was to assess the diagnostic ability of MDCT arthrography for acetabular and femoral cartilage lesions in patients with hip dysplasia. A disorder of the articular cartilage was evaluated in 20 hips of 18 patients with acetabular dysplasia who did not have osteoarthritis or who had early stage osteoarthritis before undergoing pelvic osteotomy surgery. The findings on fat-suppressed 3D fast spoiled gradient-echo MRI and MDCT arthrography of the hip were evaluated by two independent observers, and sensitivity, specificity, and accuracy were determined using arthroscopic findings as the standard of reference. Kappa values were calculated to quantify the level of interobserver agreement. The sensitivity and specificity for the detection of any cartilage disorder (grade 1 or higher) were (observer 1/observer 2) 49%/67% and 89%/76%, respectively, on MRI, and 67%/67% and 89%/82%, respectively, on CT arthrography. The sensitivity and specificity for the detection of cartilage lesions with substance loss (grade 2 or higher) were (observer 1/observer 2) 47%/53% and 92%/87%, respectively, on MRI, and 70%/79% and 93%/94%, respectively, on CT arthrography. CT arthrography provided significantly higher sensitivity in the detection of grade 2 or higher lesions than MRI for both observers. Interobserver agreement in the detection of grade 2 or higher cartilage lesions was moderate (kappa = 0.53) on MRI and substantial (kappa = 0.78) on CT. MDCT arthrography is a sensitive and reproducible method for assessing articular cartilage lesions with substance loss in patients with hip dysplasia.
Louie, Brian; Lei, John; Liska, Sally; Dowling, Teri; Pandori, Mark W
2009-07-01
The performances of three blood-based immunoassays test kits were compared with regard to their ability to detect HIV-1 antibody in oral fluid. It was found that these three kits differ in their ability to detect HIV-1 antibody. Notably, a third generation EIA which has been shown to possess superior sensitivity for antibody detection in plasma appears to possess no sensitivity advantage for detecting HIV-1 antibody in oral fluid.
Validating the M. D. Anderson Symptom Inventory (MDASI) for use in patients with ovarian cancer
Sailors, Mary H.; Bodurka, Diane C.; Gning, Ibrahima; Ramondetta, Lois M.; Williams, Loretta A.; Mendoza, Tito R.; Agarwal, Sonika; Sun, Charlotte C.; Cleeland, Charles S.
2013-01-01
Objective The M. D. Anderson Symptom Inventory (MDASI) captures the severity of common cancer symptoms from the patients’ perspective. We describe the validity and sensitivity of a module of the MDASI to be used with patients having ovarian cancer (MDASI-OC). Methods Ovarian cancer–specific module items were developed from 14 qualitative patient interviews. 128 patients with invasive epithelial ovarian, peritoneal, or fallopian-tube cancer treated at MD Anderson Cancer Center were recruited. Patients completed the MDASI-OC, socio-demographic questionnaires, the Functional Assessment of Cancer Therapy-Ovary (FACT-O), and a global quality-of-life (QOL) item. Reliability was assessed using Cronbach α and sensitivity using known group was assessed. Construct validity was tested using exploratory factor analysis. Results The sample was primarily white (85.2%), had a mean age of 57.5 years (±12.7 years), and had previously been treated with chemotherapy (75.0%) and/or surgery (93.8%). Approximately 30% of patients reported disturbed sleep, fatigue, or numbness/tingling of at least moderate severity (≥5 on a 0–10 scale). On the ovarian-cancer-specific symptoms, approximately 20% reported back pain, feeling bloated, or constipation of at least moderate severity. Factor analysis revealed six underlying constructs (pain/sleep; cognitive; disease-related and numbness; treatment-related; affective; gastrointestinal-specific). MDASI-OC symptom and interference items had Cronbach α values of 0.90 and 0.89, respectively. The MDASI-OC was sensitive to symptom severity by performance status (p=0.009), QOL (p=0.002), and FACT-O scores (p<0.001). Conclusions The 27-item MDASI-OC meets common criteria for validation and reliability and is sensitive to expected changes in symptoms related to differences in disease and treatment status. PMID:23685012
Wejnarska, Karolina; Kołodziejczyk, Elwira; Ryżko, Józef; Oracz, Grzegorz
Chronic pancreatitis (CP) in children is still a rare, although increasingly recognized entity. Over the duration of the disease several complications can be observed, two of which are major ones: endo- and exocrine insufficiency. In the medical care of children with CP it is crucial to diagnose the decreased endo- and exocrine function of the pancreas, in order to preserve patients from malnutrition and the failure to thrive. The aim of the study was to compare the usefulness of two indirect methods of assessing the pancreas exocrine function in children with CP. Ninety one patients with CP were enrolled in the study (41 boys, 50 girls, aged 2-17.8 years). Only Patients who had had both the 72-hour fecal fat quantification and the 13C-mixed triglyceride breath test (13C -MTBT) performed were selected. We compared the results of both tests for sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) in detecting exocrine pancreatic insufficiency. Out of 91 patients, 12 were diagnosed with exocrine pancreatic insufficiency (EPI). The sensitivity of the fecal fat quantification was 50%, the specificity for the test was 100%. PPV and NPV were 100% and 93%, respectively. 13C-MTBT had the sensitivity of 42% and the specificity of 99%. PPV and NPV for the breath test were of 83% and 92%, respectively. No statistically significant discrepancy between the values obtained was found. Although the 72-hour fecal fat quantification remains the gold standard in detecting EPI, both of the methods that had been investigated were shown to be comparable regarding sensitivity, specificity, PPV and NPV in assessing pancreas exocrine sufficiency in children with CP. Due to the easier execution of the breath test, both for the patient and for medical personnel, its importance may increase.
Dry-eye screening by using a functional visual acuity measurement system: the Osaka Study.
Kaido, Minako; Uchino, Miki; Yokoi, Norihiko; Uchino, Yuichi; Dogru, Murat; Kawashima, Motoko; Komuro, Aoi; Sonomura, Yukiko; Kato, Hiroaki; Kinoshita, Shigeru; Tsubota, Kazuo
2014-05-06
We determined whether functional visual acuity (VA) parameters and a dry eyes (DEs) symptoms questionnaire could predict DEs in a population of visual terminal display (VDT) users. This prospective study included 491 VDT users from the Osaka Study. Subjects with definite DE, diagnosed with the presence of DE symptoms, tear abnormality (Schirmer test ≤ 5 mm or tear breakup time [TBUT] ≤ 5 seconds), and conjunctivocorneal epithelial damage (total staining score of ≥3 points), or probable DE, diagnosed with the presence of two of them, were assigned to a DE group, and the remainder to a non-DE group. Functional VA was assessed, and DE questionnaires were administered. We assessed whether univariate and discriminant analyses could determine to which group a subject belonged. Sensitivity and specificity were assessed. Of 491 subjects, 320 and 171 were assigned to the DE and non-DE groups, respectively. No significant differences were observed between DE and non-DE groups in Schirmer test value and epithelial damage, but TBUT value (3.1 ± 1.5 vs. 5.9 ± 3.0 seconds). The sensitivity and specificity of single test using functional VA parameters were 59% and 49% in functional VA, 60% and 50% in visual maintenance ratio, and 83% and 30% in frequency of blinking, respectively. According to a discriminant analysis using a combination of functional VA parameters and a DE questionnaire, six variables were selected for the discriminant equation, of which area under the curve (AUC) was 0.735. Sensitivity and specificity of diagnoses predicted by the discriminant equation were 85.9% and 45.6%, respectively. The discriminant equation obtained using functional VA measurement combined with a symptoms questionnaire may suggest the possibility for the first step screening of DE with unstable tear film. Since the questionnaire has an overall poor sensitivity and specificity, further amelioration may be necessary for the actual utilization of this screening tool. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Non-localization and localization ROC analyses using clinically based scoring
NASA Astrophysics Data System (ADS)
Paquerault, Sophie; Samuelson, Frank W.; Myers, Kyle J.; Smith, Robert C.
2009-02-01
We are investigating the potential for differences in study conclusions when assessing the estimated impact of a computer-aided detection (CAD) system on readers' performance. The data utilized in this investigation were derived from a multi-reader multi-case observer study involving one hundred mammographic background images to which fixed-size and fixed-intensity Gaussian signals were added, generating a low- and high-intensity signal sets. The study setting allowed CAD assessment in two situations: when CAD sensitivity was 1) superior or 2) lower than the average reader. Seven readers were asked to review each set in the unaided and CAD-aided reading modes, mark and rate their findings. Using this data, we studied the effect on study conclusion of three clinically-based receiver operating characteristic (ROC) scoring definitions. These scoring definitions included both location-specific and non-location-specific rules. The results showed agreement in the estimated impact of CAD on the overall reader performance. In the study setting where CAD sensitivity is superior to the average reader, the mean difference in AUC between the CAD-aided read and unaided read was 0.049 (95%CIs: -0.027; 0.130) for the image scoring definition that is based on non-location-specific rules, and 0.104 (95%CIs: 0.036; 0.174) and 0.090 (95%CIs: 0.031; 0.155) for image scoring definitions that are based on location-specific rules. The increases in AUC were statistically significant for the location-specific scoring definitions. It was further observed that the variance on these estimates was reduced when using the location-specific scoring definitions compared to that using a non-location-specific scoring definition. In the study setting where CAD sensitivity is equivalent or lower than the average reader, the mean differences in AUC are slightly above 0.01 for all image scoring definitions. These increases in AUC were not statistical significant for any of the image scoring definitions. The results on the variance analysis differed from those observed in the other study setting. This investigation furthers our understanding of the relationships between non-localization-specific and localization-specific ROC assessment methodologies and their relevance to clinical practice.
Buisman, Leander R; Luime, Jolanda J; Oppe, Mark; Hazes, Johanna M W; Rutten-van Mölken, Maureen P M H
2016-06-10
There is a lack of information about the sensitivity, specificity and costs new diagnostic tests should have to improve early diagnosis of rheumatoid arthritis (RA). Our objective was to explore the early cost-effectiveness of various new diagnostic test strategies in the workup of patients with inflammatory arthritis (IA) at risk of having RA. A decision tree followed by a patient-level state transition model, using data from published literature, cohorts and trials, was used to evaluate diagnostic test strategies. Alternative tests were assessed as add-on to or replacement of the ACR/EULAR 2010 RA classification criteria for all patients and for intermediate-risk patients. Tests included B-cell gene expression (sensitivity 0.60, specificity 0.90, costs €150), MRI (sensitivity 0.90, specificity 0.60, costs €756), IL-6 serum level (sensitivity 0.70, specificity 0.53, costs €50) and genetic assay (sensitivity 0.40, specificity 0.85, costs €750). Patients with IA at risk of RA were followed for 5 years using a societal perspective. Guideline treatment was assumed using tight controlled treatment based on DAS28; if patients had a DAS28 >3.2 at 12 months or later patients could be eligible for starting biological drugs. The outcome was expressed in incremental cost-effectiveness ratios (€2014 per quality-adjusted life year (QALY) gained) and headroom. The B-cell test was the least expensive strategy when used as an add-on and as replacement in intermediate-risk patients, making it the dominant strategy, as it has better health outcomes and lower costs. As add-on for all patients, the B-cell test was also the most cost-effective test strategy. When using a willingness-to-pay threshold of €20,000 per QALY gained, the IL-6 and MRI strategies were not cost-effective, except as replacement. A genetic assay was not cost-effective in any strategy. Probabilistic sensitivity analysis revealed that the B-cell test was consistently superior in all strategies. When performing univariate sensitivity analysis for intermediate-risk patients, specificity and DAS28 in the B-cell add-on strategy, and DAS28 and sensitivity in the MRI add-on strategy had the largest impact on the cost-effectiveness. This early cost-effectiveness analysis indicated that new tests to diagnose RA are most likely to be cost-effective when the tests are used as an add-on in intermediate-risk patients, and have high specificity, and the test costs should not be higher than €200-€300.
Utility of CT Findings in the Diagnosis of Cecal Volvulus.
Dane, Bari; Hindman, Nicole; Johnson, Evan; Rosenkrantz, Andrew B
2017-10-01
The objective of our study was to assess the utility of CT features in the diagnosis of cecal volvulus. Forty-three patients undergoing CT for cecal volvulus and with surgical or clinical follow-up were included. Two radiologists (11 years and 1 year of experience) evaluated CT examinations for the following: whirl sign, abnormal cecal position, "bird beak" sign, severe cecal distention, mesenteric engorgement, a newly described "central appendix" sign (defined as abnormal appendix position near midline), and overall impression for cecal volvulus. Univariable and multivariable assessments were performed. Patients with CT examinations in which the appendix was not visible were excluded from calculations involving the central appendix sign. Fifty-one percent (n = 22) of patients had cecal volvulus. All CT findings were significantly more common in patients with cecal volvulus (p < 0.01) other than mesenteric engorgement for reader 1 (p = 0.332). Readers 1 and 2 identified the central appendix sign in 92.9% and 92.3% of patients with volvulus versus in 37.5 and 31.1% of patients without volvulus. The whirl sign exhibited a sensitivity for cecal volvulus of 90.9% for reader 1 and 95.5% for reader 2, and a specificity of 61.9% for both readers. Abnormal cecal position exhibited a sensitivity of 90.0% for reader 1 and 100.0% for reader 2 and a specificity of 66.7% and 38.1%. The bird beak sign exhibited a sensitivity of 86.4% for reader 1 and 100.0% for reader 2 and a specificity of 85.7% and 71.4%. Severe cecal distention exhibited a sensitivity of 100.0% for both readers and a specificity of 81.0% and 61.9%. Mesenteric engorgement exhibited a sensitivity of 40.9% for reader 1 and 100.0% for reader 2 and a specificity of 76.2% and 71.4%. The central appendix sign exhibited a sensitivity of 92.9% for reader 1 and 92.3% for reader 2 and a specificity of 62.5% and 68.8%. Overall impression exhibited a sensitivity of 100.0% for both readers and a specificity of 76.2% and 57.1%. At multivariable analysis, the AUC for cecal volvulus ranged from 0.787 to 0.931, and the whirl sign was an independent predictor of volvulus for both readers (p ≤ 0.014); the central appendix sign was also an independent predictor in patients with a visualized appendix for reader 2 (p ≤ 0.001). CT exhibited high diagnostic performance and very high sensitivity for cecal volvulus. The whirl sign was a significant independent predictor of volvulus for both readers.
Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L
2016-01-01
Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis.
Nliwasa, Marriott; MacPherson, Peter; Chisala, Palesa; Kamdolozi, Mercy; Khundi, McEwen; Kaswaswa, Kruger; Mwapasa, Mphatso; Msefula, Chisomo; Sohn, Hojoon; Flach, Clare; Corbett, Elizabeth L.
2016-01-01
Background Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. Objective To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic cough compared to Xpert® MTB/RIF, fluorescence smear microscopy. Methods Between October 2013 and March 2014, consecutive adults at a primary care clinic were screened for cough, offered HIV testing and assessed for tuberculosis using LAMP, Xpert® MTB/RIF and fluorescence smear microscopy. Sensitivity and specificity (with culture as reference standard), and costs were estimated. Results Of 273 adults recruited, 44.3% (121/273) were HIV-positive and 19.4% (53/273) had bacteriogically confirmed tuberculosis. The sensitivity of LAMP compared to culture was 65.0% (95% CI: 48.3% to 79.4%) with 100% (95% CI: 98.0% to 100%) specificity. The sensitivity of Xpert® MTB/RIF (77.5%, 95% CI: 61.5% to 89.2%) was similar to that of LAMP, p = 0.132. The sensitivity of concentrated fluorescence smear microscopy with routine double reading (87.5%, 95% CI: 73.2% to 95.8%) was higher than that of LAMP, p = 0.020. All three tests had high specificity. The lowest cost per test of LAMP was at batch size of 14 samples (US$ 9.98); this was lower than Xpert® MTB/RIF (US$ 13.38) but higher than fluorescence smear microscopy (US$ 0.65). Conclusion The sensitivity of LAMP was similar to Xpert® MTB/RIF but lower than fluorescence smear microscopy; all three tests had high specificity. These findings support the Malawi policy that recommends a combination of fluorescence smear microscopy and Xpert® MTB/RIF prioritised for people living with HIV, already found to be smear-negative, or being considered for retreatment of tuberculosis. PMID:27171380
Clinical Evaluation of the Concussed Athlete: A View From the Sideline.
Putukian, Margot
2017-03-01
The sideline assessment of concussion is challenging, given its variable presentations, the limited sensitivity and specificity of sideline assessment tools, and how the presentation of the injury evolves over time. In addition, the diagnostic process, as well as the tools used to assess and manage concussion, continue to progress as research and what we know about concussion advance. This paper focuses on the initial assessment on the sideline by reviewing the concussion-evaluation literature, drawing from clinical experience to emphasize a standardized approach, and underscoring the importance of both familiarity with the athlete and clinical judgment. To review the evidence regarding the clinical assessment of sport-related concussion on the sideline. Additional considerations included making same-day return-to-play decisions, the sensitivity and specificity of sideline testing, and the importance of ongoing assessment and follow-up of injured athletes. I conducted a systematic literature review of the assessment of concussion on the sideline. The PubMed and MEDLINE databases were searched using the key term athletic injuries with concussion and mild traumatic brain injury. The search was refined by adding the key terms sideline assessment and on-field assessment. In addition, select additional position statements and guidelines on concussion were included in the review. The PubMed search using athletic injuries and concussion as key terms produced 1492 results. Refining the search by sideline assessment and on-field assessment produced 29 and 35 results, respectively. When athletic injuries and traumatic brain injury were combined, 1912 results were identified. Refining the search by sideline assessment and on-field assessment led to 28 and 35 results, respectively. Only papers that were English-language titles, original work, and limited to human participants and included sideline assessments of sport-related concussion in athletes older than 13 years were considered for this discussion. A total of 96 papers were reviewed, including systematic reviews, consensus guidelines, and position statements. The sideline assessment of sport-related concussion is challenging given the elusiveness and variability of presentation, reliance on athlete-reported symptoms, and the varying specificity and sensitivity values of sideline assessment tools. In addition, the recognition of injury and assessment often occur in a time-pressured environment, requiring rapid disposition and decision making. Clinicians should begin the evaluation by assessing for cervical spine injury, intracranial bleeding, and other injuries that can present in a similar fashion or in addition to concussion. The sideline concussion evaluation should consist of a symptom assessment and a neurologic examination that addresses cognition (briefly), cranial nerve function, and balance. Emerging tools that assess visual tracking may provide additional information. The sensitivity and specificity of commonly implemented sideline assessment tools are generally good to very good, especially for symptom scores and cognitive evaluations performed within 48 hours of injury, and they are improved when a baseline evaluation is available for comparison. Serial assessments are often necessary as objective signs and symptoms may be delayed. A standardized assessment is paramount in evaluating the athlete with a suspected concussion, but there is no replacement for being familiar with the athlete and using clinical judgment when the athlete seems "not right" despite a "normal" sideline assessment. Ultimately, the clinician should err on the side of caution when making a return-to-play decision.
Stewart, Duncan; Waller, David; Edwards, John; Jeyapalan, Kanagaratnam; Entwisle, James
2003-12-01
To assess the use of contrast-enhanced magnetic resonance imaging (CEMRI) in addition to computed tomography in the pre-operative assessment of patients for radical surgery in malignant pleural mesothelioma. Over a 45-month period, 51 of 76 patients assessed (69 men and seven women), underwent extra-pleural pneumonectomy or radical pleurectomy/decortication. Post-operative pathological stage was correlated with radiological staging, with particular emphasis on tumour resectability. Seventeen (22%) patients were found on CEMRI to have unresectable, but histologically unconfirmed disease, not previously seen on CT. Fifty-one (67%) patients proceeded to radical surgery, but pathological nodal data were incomplete in three, so excluding these patients from further analyses. The median pre-operative interval after CEMRI was 17 days. Two patients were found to have unexpectedly extensive disease at thoracotomy, thus the sensitivity of CEMRI for prediction of resectability was 97%. Using the International Mesothelioma Interest Group system, tumour stage was correctly predicted by CEMRI in 48% of patients, but understaged in 50% of cases, largely due to the underestimation of pericardial involvement, but this did not affect resectability and had no significant effect on prognosis. Nodal stage was correctly identified in 60% of patients. CEMRI was successful in predicting pathological tumour stage T3 or less (sensitivity of 85%; specificity of 100%), but less so in identifying tumour stage T2 or less (sensitivity of 23%; specificity of 96%) or N2 nodal disease (sensitivity 66%; specificity 73%). CEMRI is most useful in the differentiation of T3 and T4 disease and may be unnecessary at earlier stages. Its multiplanar tumour localisation abilities are of value in the assessment of resectability. It is unlikely to contribute significantly to nodal staging, but it remains a valuable adjunct in the selection of patients for radical surgery.
Cooper, K L; Meng, Y; Harnan, S; Ward, S E; Fitzgerald, P; Papaioannou, D; Wyld, L; Ingram, C; Wilkinson, I D; Lorenz, E
2011-01-01
Breast cancer is the most common type of cancer in women. Evaluation of axillary lymph node metastases is important for breast cancer staging and treatment planning. To evaluate the diagnostic accuracy, cost-effectiveness and effect on patient outcomes of positron emission tomography (PET), with or without computed tomography (CT), and magnetic resonance imaging (MRI) in the evaluation of axillary lymph node metastases in patients with newly diagnosed early-stage breast cancer. A systematic review of literature and an economic evaluation were carried out. Key databases (including MEDLINE, EMBASE and nine others) plus research registers and conference proceedings were searched for relevant studies up to April 2009. A decision-analytical model was developed to determine cost-effectiveness in the UK. One reviewer assessed titles and abstracts of studies identified by the search strategy, obtained the full text of relevant papers and screened them against inclusion criteria. Data from included studies were extracted by one reviewer using a standardised data extraction form and checked by a second reviewer. Discrepancies were resolved by discussion. Quality of included studies was assessed using the quality assessment of diagnostic accuracy studies (QUADAS) checklist, applied by one reviewer and checked by a second. Forty-five citations relating to 35 studies were included in the clinical effectiveness review: 26 studies of PET and nine studies of MRI. Two studies were included in the cost-effectiveness review: one of PET and one of MRI. Of the seven studies evaluating PET/CT (n = 862), the mean sensitivity was 56% [95% confidence interval (CI) 44% to 67%] and mean specificity 96% (95% CI 90% to 99%). Of the 19 studies evaluating PET only (n = 1729), the mean sensitivity was 66% (95% CI 50% to 79%) and mean specificity 93% (95% CI 89% to 96%). PET performed less well for small metastases; the mean sensitivity was 11% (95% CI 5% to 22%) for micrometastases (≤ 2 mm; five studies; n = 63), and 57% (95% CI 47% to 66%) for macrometastases (> 2 mm; four studies; n = 111). The smallest metastatic nodes detected by PET measured 3 mm, while PET failed to detect some nodes measuring > 15 mm. Studies in which all patients were clinically node negative showed a trend towards lower sensitivity of PET compared with studies with a mixed population. Across five studies evaluating ultrasmall super-paramagnetic iron oxide (USPIO)-enhanced MRI (n = 93), the mean sensitivity was 98% (95% CI 61% to 100%) and mean specificity 96% (95% CI 72% to 100%). Across three studies of gadolinium-enhanced MRI (n = 187), the mean sensitivity was 88% (95% CI 78% to 94%) and mean specificity 73% (95% CI 63% to 81%). In the single study of in vivo proton magnetic resonance spectroscopy (n = 27), the sensitivity was 65% (95% CI 38% to 86%) and specificity 100% (95% CI 69% to 100%). USPIO-enhanced MRI showed a trend towards higher sensitivity and specificity than gadolinium-enhanced MRI. Results of the decision modelling suggest that the MRI replacement strategy is the most cost-effective strategy and dominates the baseline 4-node sampling (4-NS) and sentinel lymph node biopsy (SLNB) strategies in most sensitivity analyses undertaken. The PET replacement strategy is not as robust as the MRI replacement strategy, as its cost-effectiveness is significantly affected by the utility decrement for lymphoedema and the probability of relapse for false-negative (FN) patients. No included studies directly compared PET and MRI. Studies demonstrated that PET and MRI have lower sensitivity and specificity than SLNB and 4-NS but are associated with fewer adverse events. Included studies indicated a significantly higher mean sensitivity for MRI than for PET, with USPIO-enhanced MRI providing the highest sensitivity. However, sensitivity and specificity of PET and MRI varied widely between studies, and MRI studies were relatively small and varied in their methods; therefore, results should be interpreted with caution. Decision modelling based on these results suggests that the most cost-effective strategy may be MRI rather than SLNB or 4-NS. This strategy reduces costs and increases quality-adjusted life-years (QALYs) because there are fewer adverse events for the majority of patients. However, this strategy leads to more FN cases at higher risk of cancer recurrence and more false- positive (FP) cases who would undergo unnecessary axillary lymph node dissection. Adding MRI prior to SLNB or 4-NS has little effect on QALYs, though this analysis is limited by lack of available data. Future research should include large, well-conducted studies of MRI, particularly using USPIO; data on the long-term impacts of lymphoedema on cost and patient utility; studies of the comparative effectiveness and cost-effectiveness of SLNB and 4-NS; and more robust UK cost data for 4-NS and SLNB as well as the cost of MRI and PET techniques. This study was funded by the Health Technology Assessment programme of the National Institute of Health Research.
Carbone, V; van der Krogt, M M; Koopman, H F J M; Verdonschot, N
2016-06-14
Subject-specific musculoskeletal (MS) models of the lower extremity are essential for applications such as predicting the effects of orthopedic surgery. We performed an extensive sensitivity analysis to assess the effects of potential errors in Hill muscle-tendon (MT) model parameters for each of the 56 MT parts contained in a state-of-the-art MS model. We used two metrics, namely a Local Sensitivity Index (LSI) and an Overall Sensitivity Index (OSI), to distinguish the effect of the perturbation on the predicted force produced by the perturbed MT parts and by all the remaining MT parts, respectively, during a simulated gait cycle. Results indicated that sensitivity of the model depended on the specific role of each MT part during gait, and not merely on its size and length. Tendon slack length was the most sensitive parameter, followed by maximal isometric muscle force and optimal muscle fiber length, while nominal pennation angle showed very low sensitivity. The highest sensitivity values were found for the MT parts that act as prime movers of gait (Soleus: average OSI=5.27%, Rectus Femoris: average OSI=4.47%, Gastrocnemius: average OSI=3.77%, Vastus Lateralis: average OSI=1.36%, Biceps Femoris Caput Longum: average OSI=1.06%) and hip stabilizers (Gluteus Medius: average OSI=3.10%, Obturator Internus: average OSI=1.96%, Gluteus Minimus: average OSI=1.40%, Piriformis: average OSI=0.98%), followed by the Peroneal muscles (average OSI=2.20%) and Tibialis Anterior (average OSI=1.78%) some of which were not included in previous sensitivity studies. Finally, the proposed priority list provides quantitative information to indicate which MT parts and which MT parameters should be estimated most accurately to create detailed and reliable subject-specific MS models. Copyright © 2016 Elsevier Ltd. All rights reserved.
Koenig, Helen C; Finkel, Barbara B; Khalsa, Satjeet S; Lanken, Paul N; Prasad, Meeta; Urbani, Richard; Fuchs, Barry D
2011-01-01
Lung protective ventilation reduces mortality in patients with acute lung injury, but underrecognition of acute lung injury has limited its use. We recently validated an automated electronic acute lung injury surveillance system in patients with major trauma in a single intensive care unit. In this study, we assessed the system's performance as a prospective acute lung injury screening tool in a diverse population of intensive care unit patients. Patients were screened prospectively for acute lung injury over 21 wks by the automated system and by an experienced research coordinator who manually screened subjects for enrollment in Acute Respiratory Distress Syndrome Clinical Trials Network (ARDSNet) trials. Performance of the automated system was assessed by comparing its results with the manual screening process. Discordant results were adjudicated blindly by two physician reviewers. In addition, a sensitivity analysis using a range of assumptions was conducted to better estimate the system's performance. The Hospital of the University of Pennsylvania, an academic medical center and ARDSNet center (1994-2006). Intubated patients in medical and surgical intensive care units. None. Of 1270 patients screened, 84 were identified with acute lung injury (incidence of 6.6%). The automated screening system had a sensitivity of 97.6% (95% confidence interval, 96.8-98.4%) and a specificity of 97.6% (95% confidence interval, 96.8-98.4%). The manual screening algorithm had a sensitivity of 57.1% (95% confidence interval, 54.5-59.8%) and a specificity of 99.7% (95% confidence interval, 99.4-100%). Sensitivity analysis demonstrated a range for sensitivity of 75.0-97.6% of the automated system under varying assumptions. Under all assumptions, the automated system demonstrated higher sensitivity than and comparable specificity to the manual screening method. An automated electronic system identified patients with acute lung injury with high sensitivity and specificity in diverse intensive care units of a large academic medical center. Further studies are needed to evaluate the effect of automated prompts that such a system can initiate on the use of lung protective ventilation in patients with acute lung injury.
Fussner, Lauren M; Luebbe, Aaron M; Smith, April R
2018-08-01
Disordered eating symptoms are associated with disrupted sensitivity to reward and punishment, broadly assessed. However, it is unknown how eating pathology is related to sensitivity to social reward and social punishment specifically. Drawing on Reinforcement Sensitivity Theory, the current study utilized a multi-method design to test whether disordered eating symptoms, specifically dietary restraint (DR) and binge/purge (BP), were similarly or uniquely related to sensitivity to social punishment and social reward. Female university students (N = 110, M = 18.66, SD = 0.89) completed self-report measures and a novel behavioral task measuring willingness to work for or to avoid social feedback. DR and BP symptoms were related to increased self-reported and behavioral sensitivity to social punishment, yet only when symptoms were tested in isolation. DR was associated with increased sensitivity to social reward across self-report and behavioral paradigms. BP symptoms were uniquely and positively related to self-reported sensitivity to social reward, but decreased behavioral sensitivity to social reward. Findings suggest that sensitivity to punishment may be a common factor related to DR and BP, whereas sensitivity to social reward may be a key factor differentiating disordered eating symptoms. Copyright © 2018 Elsevier Ltd. All rights reserved.
The Danish test battery for auditory processing disorder evaluated with patient and control data.
Raben Pedersen, Ellen
2018-06-10
This study evaluates the Danish test battery for auditory processing disorder (APD). The battery consists of four behavioural tests, two speech and two non-speech stimuli tests. The evaluation includes determination of: (1) new cut-off values (pass-fail criteria), (2) the sensitivity and the specificity of the entire test battery and (3) the failure rate of different test combinations. For each test in the battery, cut-off values were determined using the weighted Youden index. Applying the newly derived cut-off values, the distribution of failing specific test combinations was determined. A group of 112 children diagnosed with APD (57 boys, 55 girls, aged 6-16 years) and a control group containing 158 children without auditory problems (75 boys, 83 girls, aged 6-16 years). Cut-off values for different weights of the sensitivity and the specificity have been determined. Using the criterion that at least two tests have to be failed for APD to be suspected, the sensitivity and the specificity of the entire test battery were 95.3% and 91.6%, respectively. Some test combinations were found to have higher failure rates than others. Due to the high sensitivity and specificity the test battery has good predictive value in APD assessment.
Cytological diagnostic of lymphadenitis tuberculosis by eosinophilic material
NASA Astrophysics Data System (ADS)
Delyuzar; Amir, Z.; Kusumawati, L.
2018-03-01
AFB sputum and chest X-ray are used to identify patients with pulmonary TB. For extrapulmonary TB, fine needle aspiration cytology is needed, even though occasionally found not atypical feature in the form of eosinophilic material with dark brown particles, suspected as TB. This research was to show that eosinophilic material with dark brown particles is accurate as new criteria for the cytological diagnosis of TB. By performing fine needle aspiration biopsy stained with Giemsa, if an eosinophilic material with dark brown particles was encountered, we continued with Ziehl-Neelsen AFB stain and confirmed with PCR. To assess accuracy, we used a diagnostic test to evaluate sensitivity and specificity of eosinophilic material with dark brown particles by using AFB and PCR as the gold standard. The sensitivity and specificity of cytological diagnosis in tuberculosis of eosinophilic material with dark brown particles were 93.65% and 70.99%, respectively if confirmed with AFB. On the other hand, if confirmed with PCR using Mycobacterium tuberculosis DNA, the sensitivity and specificity were 98.95% and 96.79%, respectively. In conclusion, eosinophilic masses with dark brown particles is accurate as new criteria of TB diagnostic cytology with high sensitivity and specificity confirmed with AFB and PCR test.
Presence of functional, autoreactive human milk-specific IgE in infants with cow’s milk allergy
Järvinen, K. M.; Geller, L.; Bencharitiwong, R.; Sampson, H. A.
2013-01-01
Summary Background Occasionally, exclusively breastfed infants with cow’s milk allergy (CMA) remain symptomatic despite strict maternal milk avoidance. Objective To determine whether or not persistence of symptoms could be due to sensitization against endogenous human milk proteins with a high degree of similarity to bovine allergens. Methods Ten peptides representing known bovine milk IgE-binding epitopes [α-lactalbumin (ALA), β- and κ-casein] and the corresponding, highly homologous human milk peptides were labelled with sera from 15 breastfed infants with CMA, aged 3 weeks to 12 months, and peptide (epitope)-specific IgE antibodies were assessed. Nine of the 15 breastfed infants became asymptomatic during strict maternal avoidance of milk and other major food allergens; six infants remained symptomatic until weaned. Ten older children, aged 5–15 years, with CMA were also assessed. The functional capacity of specific IgE antibodies was assessed by measuring β-hexosaminidase release from rat basophilic leukaemia cells passively sensitized and stimulated with human and bovine ALA. Results A minimum of one human milk peptide was recognized by IgE antibodies from 9 of 15 (60%) milk-allergic infants, and the majority of older children with CMA. Genuine sensitization to human milk peptides in the absence of IgE to bovine milk was occasionally seen. There was a trend towards specific IgE being detected to more human milk peptides in those infants who did not respond to the maternal milk elimination diet than in those who did (P = 0.099). Functional IgE antibody to human ALA was only detected in infants not responding to the maternal diet. Conclusions and Clinical Relevance Endogenous human milk epitopes are recognized by specific IgE from the majority of infants and children with CMA. Such autoreactive, human milk-specific IgE antibodies appear to have functional properties in vitro. Their role in provoking allergic symptoms in infants exclusively breastfed by mothers strictly avoiding dietary milk remains unclear. PMID:22092935
Presence of functional, autoreactive human milk-specific IgE in infants with cow's milk allergy.
Järvinen, K M; Geller, L; Bencharitiwong, R; Sampson, H A
2012-02-01
Occasionally, exclusively breastfed infants with cow's milk allergy (CMA) remain symptomatic despite strict maternal milk avoidance. To determine whether or not persistence of symptoms could be due to sensitization against endogenous human milk proteins with a high degree of similarity to bovine allergens. Ten peptides representing known bovine milk IgE-binding epitopes [α-lactalbumin (ALA), β- and κ-casein] and the corresponding, highly homologous human milk peptides were labelled with sera from 15 breastfed infants with CMA, aged 3 weeks to 12 months, and peptide (epitope)-specific IgE antibodies were assessed. Nine of the 15 breastfed infants became asymptomatic during strict maternal avoidance of milk and other major food allergens; six infants remained symptomatic until weaned. Ten older children, aged 5-15 years, with CMA were also assessed. The functional capacity of specific IgE antibodies was assessed by measuring β-hexosaminidase release from rat basophilic leukaemia cells passively sensitized and stimulated with human and bovine ALA. A minimum of one human milk peptide was recognized by IgE antibodies from 9 of 15 (60%) milk-allergic infants, and the majority of older children with CMA. Genuine sensitization to human milk peptides in the absence of IgE to bovine milk was occasionally seen. There was a trend towards specific IgE being detected to more human milk peptides in those infants who did not respond to the maternal milk elimination diet than in those who did (P = 0.099). Functional IgE antibody to human ALA was only detected in infants not responding to the maternal diet. Endogenous human milk epitopes are recognized by specific IgE from the majority of infants and children with CMA. Such autoreactive, human milk-specific IgE antibodies appear to have functional properties in vitro. Their role in provoking allergic symptoms in infants exclusively breastfed by mothers strictly avoiding dietary milk remains unclear. © 2011 Blackwell Publishing Ltd.
Immunophenotyping does not improve predictivity of the local lymph node assay in mice.
Strauss, Volker; Kolle, Susanne N; Honarvar, Naveed; Dammann, Martina; Groeters, Sibylle; Faulhammer, Frank; Landsiedel, Robert; van Ravenzwaay, Bennard
2015-04-01
The local lymph node assay (LLNA) is a regulatory accepted test for the identification of skin sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. However, there is evidence that LLNA is overestimating the sensitization potential of certain substance classes in particular those exerting skin irritation. Some reports describe the additional use of flow cytometry-based immunophenotyping to better discriminate irritants from sensitizing irritants in LLNA. In the present study, the 22 performance standards plus 8 surfactants were assessed using the radioactive LLNA method. In addition, lymph node cells were immunophenotyped to evaluate the specificity of the lymph node response using cell surface markers such as B220 or CD19, CD3, CD4, CD8, I-A(κ) and CD69 with the aim to allow a better discrimination above all between irritants and sensitizers, but also non-irritating sensitizers and non-sensitizers. However, the markers assessed in this study do not sufficiently differentiate between irritants and irritant sensitizers and therefore did not improve the predictive capacity of the LLNA. Copyright © 2014 John Wiley & Sons, Ltd.
External Quality Assessment for Zika Virus Molecular Diagnostic Testing, Brazil.
Fischer, Carlo; Pedroso, Celia; Mendrone, Alfredo; Bispo de Filippis, Ana Maria; Vallinoto, Antonio Carlos Rosário; Ribeiro, Bergmann Morais; Durigon, Edison Luiz; Marques, Ernesto T A; Campos, Gubio S; Viana, Isabelle F T; Levi, José Eduardo; Scarpelli, Luciano Cesar; Nogueira, Mauricio Lacerda; Bastos, Michele de Souza; Souza, Nathalia C Santiago; Khouri, Ricardo; Lira, Sanny; Komninakis, Shirley Vasconcelos; Baronti, Cécile; Charrel, Rémi N; Kümmerer, Beate M; Drosten, Christian; Brites, Carlos; de Lamballerie, Xavier; Niedrig, Matthias; Netto, Eduardo Martins; Drexler, Jan Felix
2018-05-01
We conducted an external quality assessment of Zika virus molecular diagnostic tests in Brazil using a new Zika virus standard. Of 15 laboratories, 73% showed limited sensitivity and specificity. Viral load estimates varied significantly. Continuous quality assurance is needed to adequately estimate risk for Zika virus-associated disease and determine patient care.
Wsol, Agnieszka; Wydra, Wioletta; Chmielewski, Marek; Swiatowiec, Andrzej; Kuch, Marek
2017-01-01
A retrospective study was designed to investigate P-wave duration changes in exercise stress test (EST) for the prediction of angiographically documented substantial coronary artery disease (CAD). We analyzed 265 cases of patients, who underwent EST and subsequently coronary angiography. Analysis of P-wave duration was performed in leads II, V5 at rest, and in the recovery period. The sensitivity and specificity for the isolated ST-segment depression were only 31% and 76%, respectively. The combination of ST-depression with other exercise-induced clinical and electrocardio-graphic abnormalities (chest pain, ventricular arrhythmia, hypotension, left bundle branch block) was characterized by 41% sensitivity and 69% specificity. The combination of abnormal recovery P-wave duration (≥ 120 ms) with ST-depression and other exercise-induced abnormalities had 83% sensitivity but only 20% specificity. Combined analysis of increased delta P-wave duration, ST-depression and other exercise-induced abnormalities had 69% sensitivity and 42% specificity. Sensitivity and specificity of the increase in delta P-wave duration for left CAD was 69% and 47%, respectively, and for 3-vessel CAD 70% and 50%, respectively. The presence of arterial hypertension negatively influenced the prog-nostic value of P-wave changes in the stress test. The results of the study show that an addition of P-wave duration changes assessment to ST-depression analysis and other exercise-induced abnormalities increase sensitivity of EST, especially for left CAD and 3-vessel coronary disease. We have also provided evidence for the negative influence of the presence of arterial hypertension on the predictive value of P-wave changes in the stress test. (Cardiol J 2017; 24, 2: 159-166).
Amarasinghe, Nirmalie Champika; De AlwisSenevirathne, Rohini
2016-10-17
Musculoskeletal disorders (MSDs) have been identified as a predisposing factor for lesser productivity, but no validated tool has been developed to assess them in the Sri- Lankan context. To develop a validated tool to assess the neck and upper limb MSDs. It comprises three components: item selections, item reduction using principal component analysis, and validation. A tentative self-administrated questionnaire was developed, translated, and pre-tested. Four important domains - neck, shoulder, elbow and wrist - were identified through principal component analysis. Prevalence of any MSDs was 38.1% and prevalence of neck, shoulder, elbow and wrist MSDs are 12.85%, 13.71%, 12%, 13.71% respectively. Content and criterion validity of the tool was assessed. Separate ROC curves were produced and sensitivity and specificity of neck (83.1%, 71.7%), shoulder (97.6%, 91.9%), elbow (98.2%, 87.2%), and wrist (97.6%, 94.9%) was determined. Cronbach's Alpha and correlation coefficient was above 0.7. The tool has high sensitivity, specificity, internal consistency, and test re-test reliability.
Reed, S M; Howe, D K; Morrow, J K; Graves, A; Yeargan, M R; Johnson, A L; MacKay, R J; Furr, M; Saville, W J A; Williams, N M
2013-01-01
Recent work demonstrated the value of antigen-specific antibody indices (AI and C-value) to detect intrathecal antibody production against Sarcocystis neurona for antemortem diagnosis of equine protozoal myeloencephalitis (EPM). The study was conducted to assess whether the antigen-specific antibody indices can be reduced to a simple serum : cerebrospinal fluid (CSF) titer ratio to achieve accurate EPM diagnosis. Paired serum and CSF samples from 128 horses diagnosed by postmortem examination. The sample set included 44 EPM cases, 35 cervical-vertebral malformation (CVM) cases, 39 neurologic cases other than EPM or CVM, and 10 non-neurologic cases. Antibodies against S. neurona were measured in serum and CSF pairs using the SnSAG2 and SnSAG4/3 (SnSAG2, 4/3) ELISAs, and the ratio of each respective serum titer to CSF titer was determined. Likelihood ratios and diagnostic sensitivity and specificity were calculated based on serum titers, CSF titers, and serum : CSF titer ratios. Excellent diagnostic sensitivity and specificity was obtained from the SnSAG2, 4/3 serum : CSF titer ratio. Sensitivity and specificity of 93.2 and 81.1%, respectively, were achieved using a ratio cutoff of ≤100, whereas sensitivity and specificity were 86.4 and 95.9%, respectively, if a more rigorous cutoff of ≤50 was used. Antibody titers in CSF also provided good diagnostic accuracy. Serum antibody titers alone yielded much lower sensitivity and specificity. The study confirms the value of detecting intrathecal antibody production for antemortem diagnosis of EPM, and they further show that the antigen-specific antibody indices can be reduced in practice to a simple serum : CSF titer ratio. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Jabbar, Kausar J; Luthra, Rajalakshmi; Patel, Keyur P; Singh, Rajesh R; Goswami, Rashmi; Aldape, Ken D; Medeiros, L Jeffrey; Routbort, Mark J
2015-04-01
Mutation-specific antibodies for BRAF V600E and IDH1 R132H offer convenient immunohistochemical (IHC) assays to detect these mutations in tumors. Previous studies using these antibodies have shown high sensitivity and specificity, but use in routine diagnosis with qualitative assessment has not been well studied. In this retrospective study, we reviewed BRAF and IDH1 mutation-specific IHC results compared with separately obtained clinical next-generation sequencing results. For 67 tumors with combined IDH1 IHC and mutation data, IHC was unequivocally reported as positive or negative in all cases. Sensitivity of IHC for IDH1 R132H was 98% and specificity was 100% compared with mutation status. Four IHC-negative samples showed non-R132H IDH1 mutations including R132C, R132G, and P127T. For 128 tumors with combined BRAF IHC and mutation data, IHC was positive in 33, negative in 82, and equivocal in 13 tumors. The sensitivity of IHC was 97% and specificity was 99% when including only unequivocally positive or negative results. If equivocal IHC cases were included in the analysis as negative, sensitivity fell to 81%. If equivocal cases were classified as positive, specificity dropped to 91%. Eight IHC-negative samples showed non-V600E BRAF mutations including V600K, N581I, V600M, and K601E. We conclude that IHC for BRAF V600E and IDH1 R132H is relatively sensitive and specific, but there is a discordance rate that is not trivial. In addition, a significant proportion of patients harbor BRAF non-V600E or IDH1 non-R132H mutations not detectable by IHC, potentially limiting utility of IHC screening for BRAF and IDH1 mutations.
Dournes, Gaël; Berger, Patrick; Refait, John; Macey, Julie; Bui, Stephanie; Delhaes, Laurence; Montaudon, Michel; Corneloup, Olivier; Chateil, Jean-François; Marthan, Roger; Fayon, Michaël; Laurent, François
2017-10-01
Purpose To assess the diagnostic accuracy of mucus contrast characterization by using magnetic resonance (MR) imaging to discriminate allergic bronchopulmonary aspergillosis (ABPA) in cystic fibrosis (CF). Materials and Methods The study was approved by the local Ethics Committee, and all patients or their parents gave written informed consent. One hundred ten consecutive patients with CF were screened between January 2014 and July 2015. All patients underwent a non-contrast material-enhanced MR protocol that included routine T1-weighted and T2-weighted sequences. The presence of mucus with both high T1 and low T2 signal intensities and the so-called inverted mucoid impaction signal (IMIS) sign was qualitatively and quantitatively assessed by two physicians who were blinded to all other data. The reference standard for a diagnosis of ABPA was the criteria of the Cystic Fibrosis Foundation Consensus Conference. ABPA status was followed up for 1 year. Reproducibility was assessed by using the κ test, correlation was assessed by using the Spearman coefficient, and diagnostic accuracy was assessed by calculating the sensitivity and specificity of IMIS. Results One hundred eight patients with CF were included (mean age, 20 years ± 11 [standard deviation]; range, 6-53 years): 18 patients with ABPA and 90 patients without ABPA. At the lobar level, inter- and intrareader reproducibility were very good (κ > 0.90). IMIS had 94% sensitivity (95% confidence interval [CI]: 73%, 99%) and 100% specificity (95% CI: 96%, 100%) for the diagnosis of ABPA. A complete resolution of IMIS was observed in patients with ABPA after 3 months of specific treatment that was significantly correlated with decrease in total immunoglobulin E level (ρ = 0.47; P = .04). Conclusion The IMIS sign was both specific and sensitive for the diagnosis of ABPA in CF. Allergic fungal inflammation appears to induce characteristic modifications of mucus contrasts that are assessable by using a noninvasive, contrast material-free, and radiation-free method. © RSNA, 2017 Online supplemental material is available for this article.
Dascalu, A M; Cherecheanu, A P; Stana, D; Voinea, L; Ciuluvica, R; Savlovschi, C; Serban, D
2014-01-01
to investigate the sensitivity and specificity of the stereometric parameters change analysis vs. Topographic Change Analysis in early detection of glaucoma progression. 81 patients with POAG were monitored for 4 years (GAT monthly, SAP at every 6 months, optic disc photographs and HRT3 yearly). The exclusion criteria were other optic disc or retinal pathology; topographic standard deviation (TSD>30; inter-test variation of reference height>25 μm. The criterion for structural progression was the following: at least 20 adjacent super-pixels with a clinically significant decrease in height (>5%). 16 patients of the total 81 presented structural progression on TCA. The most useful stereometric parameters for the early detection of glaucoma progression were the following: Rim Area change (sensitivity 100%, specificity 74.2% for a "cut-off " value of -0.05), C/D Area change (sensitivity 85.7%, specificity 71.5% for a "cut off " value of 0.02), C/D linear change (sensitivity 85.7%, specificity 71.5% for a "cut-off " value of 0.02), Rim Volume change (sensitivity 71.4%, specificity 88.8% for a "cut-off " value of -0.04). RNFL Thickness change (<0) was highly sensitive (82%), but less specific for glaucoma progression (45,2%). Changes of the other stereometric parameters have a limited diagnostic value for the early detection of glaucoma progression. TCA is a valuable tool for the assessment of the structural progression in glaucoma patients and its inter-test variability is low. On long-term, the quantitative analysis according to stereometric parameters change is also very important. The most relevant parameters to detect progression are RA, C/D Area, Linear C/D and RV.
Torres, A; el-Ebiary, M; Padró, L; Gonzalez, J; de la Bellacasa, J P; Ramirez, J; Xaubet, A; Ferrer, M; Rodriguez-Roisin, R
1994-02-01
To assess the accuracy of clinical parameters for the diagnosis of ventilator-associated (VA) pneumonia, as well as the diagnostic value of several invasive techniques, such as protected specimen brush (PSB), bronchoalveolar lavage (BAL), fiberoptic bronchial aspirates (FBAS), and percutaneous lung needle aspiration (PLNA), we compared the results of these techniques with the histopathology of immediate postmortem pulmonary biopsies, considered the "gold standard" reference test. We studied 30 mechanically ventilated patients (age 52 +/- 21 yr; mechanical ventilation period 9 +/- 7 days) who died in an intensive care unit. All patients received prior antibiotic treatment. The following procedures were performed immediately after death: bilateral PSB, BAL, FBAS, and PLNA, as well as bilateral minithoracotomies to obtain pulmonary biopsies as close as possible to the area sampled with the other techniques. According to the histopathology 18 patients had pneumonia and 12 did not. The presence of fever (sensitivity 55%, specificity 58%), purulent secretions (sensitivity 83%, specificity 33%), and chest radiograph infiltrates (sensitivity 78%, specificity 42%) could not differentiate in all instances presence from absence of pneumonia. Quantitative bacterial cultures of lung biopsies using 10(3) cfu/g as a cutoff point had low sensitivity (40%) and low specificity (45%) and could not differentiate the histologic absence or presence of pneumonia. Considering the histopathology of pulmonary biopsies as a gold standard, we found the following sensitivities for PSB, BAL, FBAS, and PLNA: 36, 50, 44, and 25%. The specificities were 50, 45, 48, and 79%, respectively. The sensitivities and specificities of different invasive techniques are much lower than those reported in clinical studies.(ABSTRACT TRUNCATED AT 250 WORDS)
Lodh, Nilanjan; Mikita, Kei; Bosompem, Kwabena M; Anyan, William K; Quartey, Joseph K; Otchere, Joseph; Shiff, Clive J
2017-09-01
Schistosomes are easily transmitted and high chance of repeat infection, so if control strategies based on targeted mass drug administration (MDA) are to succeed it is essential to have a test that is sensitive, accurate and simple to use. It is known and regularly demonstrated that praziquantel does not always eliminate an infection so in spite of the successes of control programs a residual of the reservoir survives to re-infect snails. The issue of diagnostic sensitivity becomes more critical in the assessment of program effectiveness. While serology, such as antigen capture tests might improve sensitivity, it has been shown that the presence of species-specific DNA fragments will indicate, most effectively, the presence of active parasites. Polymerase chain reaction (PCR) can amplify and detect DNA from urine residue captured on Whatman No. 3 filter paper that is dried after filtration. Previously we have detected S. mansoni and S. haematobium parasite-specific small repeat DNA fragment from filtered urine on filter paper by PCR. In the current study, we assessed the efficacy of detection of 86 urine samples for either or both schistosome parasites by PCR and loop-mediated isothermal amplification (LAMP) that were collected from a low to moderate transmission area in Ghana. Two different DNA extraction methods, standard extraction kit and field usable LAMP-PURE kit were also evaluated by PCR and LAMP amplification. With S. haematobium LAMP amplification for both extractions showed similar sensitivity and specificity when compared with PCR amplification (100%) verified by gel electrophoresis. For S. mansoni sensitivity was highest for LAMP amplification (100%) for standard extraction than PCR and LAMP with LAMP-PURE (99% and 94%). The LAMP-PURE extraction produced false negatives, which require further investigation for this field usable extraction kit. Overall high positive and negative predictive values (90% - 100%) for both species demonstrated a highly robust approach. The LAMP approach is close to point of care use and equally sensitive and specific to detection of species-specific DNA by PCR. LAMP can be an effective means to detect low intensity infection due to its simplicity and minimal DNA extraction requirement. This will enhance the effectiveness of surveillance and MDA control programs of schistosomiasis. Copyright © 2017 Elsevier B.V. All rights reserved.
Gomez, Jessie A; Carter, Alice S; Forbes, Danielle; Gray, Sarah A O
2018-06-01
Utilizing a two-dimensional model of parenting emphasizing both (1) proximity seeking and (2) exploration, consistent with a conceptual framework rooted in attachment theory, the relations between parental insightfulness, observed parenting, and child cognitive outcomes were investigated in a low-income sample of 64 of caregivers and their young 3-5-year-old children. Specifically, observed parental sensitivity (proximity seeking) and intrusiveness (exploration) and parental insightfulness assessed dimensionally to capture Positive Insight and Focus on Child were examined in relation to child cognitive outcomes. Parental intrusiveness was negatively correlated with cognitive performance; however, parental sensitivity was not associated with child cognitive outcomes. Parents' capacity to remain child-focused during the Insightfulness Assessment was negatively correlated with observed intrusiveness and was associated with child cognitive performance. These results suggest unique contributions of dimensions of parental insightfulness and parenting behaviors to child cognitive outcomes - specifically, parents' capacity to remain focused on children's experience during the Insightfulness Assessment and nonintrusive parenting behavior, which may reflect strategies to support children's exploration.
Claesson, I M; Ytterberg, C; Johansson, S; Almkvist, O; von Koch, L
2007-03-01
This study sought to investigate the feasibility of the Free Recall and Recognition Test (FRRT) as a practical screening tool for cognitive impairment in multiple sclerosis (MS). Persons with MS (n = 227) were consecutively recruited and assessed with four cognitive tests; FRRT, Symbol Digit Modalities Test (SDMT), Paced Auditory Serial Addition Test (PASAT), and the Mini-Mental State Examination (MMSE). Disease severity was assessed by the Expanded Disability Status Scale (EDSS). The FRRT, which was completed by 99% of the cohort in approximately 5 minutes per assessment, correlated significantly with the other cognitive tests, as well as with the disease severity rating. A cut-off of 4 for the FRRT recall rendered 90% sensitivity and 25% specificity, and a cut-off of 4.2 for the FRRT recognition resulted in 70% sensitivity and 51% specificity. We conclude that the FRRT proved feasible as a practical screening tool for cognitive impairment in MS within a clinical setting.
First Trimester Maternal Serum PP13 in the Risk Assessment for Preeclampsia
ROMERO, Roberto; KUSANOVIC, Juan Pedro; THAN, Nandor Gabor; EREZ, Offer; GOTSCH, Francesca; ESPINOZA, Jimmy; EDWIN, Samuel; CHEFETZ, Ilana; GOMEZ, Ricardo; NIEN, Jyh Kae; SAMMAR, Marei; PINELES, Beth; HASSAN, Sonia S.; MEIRI, Hamutal; TAL, Yossi; KUHNREICH, Ido; PAPP, Zoltan; CUCKLE, Howard S.
2008-01-01
Objective To determine whether first trimester maternal serum Placental Protein 13 (PP13) concentrations can be used in the risk assessment for preeclampsia. Study Design This case-control study included 50 patients with preeclampsia and 250 patients with normal pregnancies. Samples were collected between 8-13 weeks of gestation. Serum PP13 concentrations were measured by ELISA and expressed as medians and multiples of the median (MoM) for gestational age. Sensitivity and specificity were derived from receiver operating characteristic curve analysis. Results 1) Serum PP13 concentration in the first trimester was significantly lower in patients who developed preterm and early-onset preeclampsia than in those with normal pregnancies; and 2) At 80% specificity, a cutoff of 0.39 MoM had a sensitivity of 100% for early-onset preeclampsia and 85% for preterm preeclampsia. Conclusion Maternal serum first trimester PP13 appears to be a reasonable marker for risk assessment, but a weak marker for severe preeclampsia at term, and ineffective for identifying mild preeclampsia at term. PMID:18539259
Sakane, Makoto; Hori, Masatoshi; Onishi, Hiromitsu; Tsuboyama, Takahiro; Ota, Takashi; Tatsumi, Mitsuaki; Ueda, Yutaka; Kimura, Toshihiro; Kimura, Tadashi; Tomiyama, Noriyuki
The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically classified into no invasion, shallow (3 mm or less), and more. Two radiologists assessed myometrial invasion on MRI. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive values, AUC, and interobserver agreement were analyzed. For assessing myometrial invasion, mean accuracy, sensitivity, specificity, positive predictive values, negative predictive values, and AUC, respectively, were as follows: 63%, 42%, 85%, 79%, 47%, and 0.75. Mean interobserver agreement was fair (k = 0.36). Shallow invasions were underestimated as no invasion on MRI in all 6 cases. Magnetic resonance imaging produced false-negative result on half of patients. The misjudgments tended to happen in patients with shallow invasion.
Pugliese, Cara E.; Kenworthy, Lauren; Bal, Vanessa Hus; Wallace, Gregory L; Yerys, Benjamin E; Maddox, Brenna B.; White, Susan W.; Popal, Haroon; Armour, Anna Chelsea; Miller, Judith; Herrington, John D.; Schultz, Robert T.; Martin, Alex; Anthony, Laura Gutermuth
2015-01-01
Recent updates have been proposed to the Autism Diagnostic Observation Schedule-2 Module 4 diagnostic algorithm. This new algorithm, however, has not yet been validated in an independent sample without intellectual disability (ID). This multi-site study compared the original and revised algorithms in individuals with ASD without ID. The revised algorithm demonstrated increased sensitivity, but lower specificity in the overall sample. Estimates were highest for females, individuals with a verbal IQ below 85 or above 115, and ages 16 and older. Best practice diagnostic procedures should include the Module 4 in conjunction with other assessment tools. Balancing needs for sensitivity and specificity depending on the purpose of assessment (e.g., clinical vs. research) and demographic characteristics mentioned above will enhance its utility. PMID:26385796
Tahmasian, Masoud; Jamalabadi, Hamidreza; Abedini, Mina; Ghadami, Mohammad R; Sepehry, Amir A; Knight, David C; Khazaie, Habibolah
2017-05-22
Sleep disturbance is common in chronic post-traumatic stress disorder (PTSD). However, prior work has demonstrated that there are inconsistencies between subjective and objective assessments of sleep disturbance in PTSD. Therefore, we investigated whether subjective or objective sleep assessment has greater clinical utility to differentiate PTSD patients from healthy subjects. Further, we evaluated whether the combination of subjective and objective methods improves the accuracy of classification into patient versus healthy groups, which has important diagnostic implications. We recruited 32 chronic war-induced PTSD patients and 32 age- and gender-matched healthy subjects to participate in this study. Subjective (i.e. from three self-reported sleep questionnaires) and objective sleep-related data (i.e. from actigraphy scores) were collected from each participant. Subjective, objective, and combined (subjective and objective) sleep data were then analyzed using support vector machine classification. The classification accuracy, sensitivity, and specificity for subjective variables were 89.2%, 89.3%, and 89%, respectively. The classification accuracy, sensitivity, and specificity for objective variables were 65%, 62.3%, and 67.8%, respectively. The classification accuracy, sensitivity, and specificity for the aggregate variables (combination of subjective and objective variables) were 91.6%, 93.0%, and 90.3%, respectively. Our findings indicate that classification accuracy using subjective measurements is superior to objective measurements and the combination of both assessments appears to improve the classification accuracy for differentiating PTSD patients from healthy individuals. Copyright © 2017 Elsevier B.V. All rights reserved.
Assessment of articular disc displacement of temporomandibular joint with ultrasound.
Razek, Ahmed Abdel Khalek Abdel; Al Mahdy Al Belasy, Fouad; Ahmed, Wael Mohamed Said; Haggag, Mai Ahmed
2015-06-01
To assess pattern of articular disc displacement in patients with internal derangement (ID) of temporomandibular joint (TMJ) with ultrasound. Prospective study was conducted upon 40 TMJ of 20 patients (3 male, 17 female with mean age of 26.1 years) with ID of TMJ. They underwent high-resolution ultrasound and MR imaging of TMJ. The MR images were used as the gold standard for calculating sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of ultrasound for diagnosis of anterior or sideway displacement of the disc. The anterior displaced disc was seen in 26 joints at MR and 22 joints at ultrasound. The diagnostic efficacy of ultrasound for anterior displacement has sensitivity of 79.3 %, specificity of 72.7 %, accuracy of 77.5 %, PPV of 88.5 %, NPV of 57.1 %, PLR of 2.9 and NLR of 0.34. The sideway displacement of disc was seen in four joints at MR and three joints at ultrasound. The diagnostic efficacy of ultrasound for sideway displacement has a sensitivity of 75 %, specificity of 63.6 %, accuracy of 66.7 %, PPV of 42.8, NPV of 87.5 %, PLR of 2.06, and NLR of 0.39. We concluded that ultrasound is a non-invasive imaging modality used for assessment of anterior and sideway displacement of the articular disc in patients with ID of TMJ.
Contrast-enhanced spectral mammography improves diagnostic accuracy in the symptomatic setting.
Tennant, S L; James, J J; Cornford, E J; Chen, Y; Burrell, H C; Hamilton, L J; Girio-Fragkoulakis, C
2016-11-01
To assess the diagnostic accuracy of contrast-enhanced spectral mammography (CESM), and gauge its "added value" in the symptomatic setting. A retrospective multi-reader review of 100 consecutive CESM examinations was performed. Anonymised low-energy (LE) images were reviewed and given a score for malignancy. At least 3 weeks later, the entire examination (LE and recombined images) was reviewed. Histopathology data were obtained for all cases. Differences in performance were assessed using receiver operator characteristic (ROC) analysis. Sensitivity, specificity, and lesion size (versus MRI or histopathology) differences were calculated. Seventy-three percent of cases were malignant at final histology, 27% were benign following standard triple assessment. ROC analysis showed improved overall performance of CESM over LE alone, with area under the curve of 0.93 versus 0.83 (p<0.025). CESM showed increased sensitivity (95% versus 84%, p<0.025) and specificity (81% versus 63%, p<0.025) compared to LE alone, with all five readers showing improved accuracy. Tumour size estimation at CESM was significantly more accurate than LE alone, the latter tending to undersize lesions. In 75% of cases, CESM was deemed a useful or significant aid to diagnosis. CESM provides immediately available, clinically useful information in the symptomatic clinic in patients with suspicious palpable abnormalities. Radiologist sensitivity, specificity, and size accuracy for breast cancer detection and staging are all improved using CESM as the primary mammographic investigation. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Tan, Laurence; Toh, Hui Jin; Sim, Lai Kiow; Low, James Alvin
2018-03-01
The current screening tools for depression can be tedious to administer, especially in the elderly population with hearing impairment and/or limited proficiency in English language. To look at the feasibility of using emoticon as a screening and assessment tool for depression in the elderly. Cross-sectional study. A total of 77 elderly patients completed the study from June 2014 to August 2015 in a general geriatric outpatient clinic of an acute care hospital in Singapore. Patients rated their mood using an emoticon scale, which ranges from 1 ( most happy face) to 7 ( most sad face). Depression was assessed using the Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV) criteria as the gold standard. Sensitivity and specificity for depression were calculated for the cutoff scores from 1 to 7 on the emoticon scale. The sensitivity percentages were low across all cutoff scores. The specificity was more than 90% for the cutoff score of 5 and above on the emoticon scale. However, all the patients who had depression diagnosed using the DSM-IV criteria did not have emoticon scores of 5 and above. The emoticon scale was easy to use, but its effectiveness in the screening of depression in the elderly needs to be explored further. The inability to use the emoticon scale as a tool may be the lack of measurements in the other domains of the DSM-IV criteria (sleep, energy, appetite, etc.), rather than failure of the emoticon scale to assess mood.
Hu, Jian-bo; Zhou, Wei-hua; Hu, Shao-hua; Huang, Man-li; Wei, Ning; Qi, Hong-li; Huang, Jin-wen; Xu, Yi
2013-01-01
To evaluate the psychometric properties of the Chinese Montreal Cognitive Assessment (MoCA-C) and assess cross-cultural differences in a community-based cohort residing in the Eastern China. The study included 72 patients with Alzheimer's disease (AD), 84 patients with mild cognitive impairment (MCI) and 146 cognitively normal controls. Sensitivities and specificities were calculated using the recommended cut-off scores. Receiver operator characteristic (ROC) curve analyses were performed to determine optimal sensitivity and specificity. Criterion validity, inter-rater, test-retest reliability and internal consistencies of the MoCA-C were examined, and clinical observations made. The influence of age, education level and gender on MoCA score was examined. Using the recommended cut-off score of 26, the area under the ROC (AUC) for predicting MCI groups using the MoCA-C was 0.930 (95%CI: 0.894; 0.965). The MoCA-C demonstrated 92% sensitivity and 85% specificity in screening for MCI. Cultural differences from the original MoCA affected the test response rate. The MoCA-C appears to have utility as a cognitive screen for early detection of AD and for MCI and warrants further investigation regarding its applicability in primary care settings in elderly Chinese people. It will be necessary to revise the contents of the questionnaire to account for by local characteristics. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Rotchés-Ribalta, Roser; Boutin, Céline; Blanco-Moreno, José M; Carpenter, David; Sans, F Xavier
2015-07-01
The decline of arable species characteristic of winter cereal fields has often been attributed to different factors related to agricultural intensification but most importantly to herbicide use. Herbicide phytotoxicity is most frequently assessed using short-term endpoints, primarily aboveground biomass. However, short-term sensitivity is usually not sufficient to detect actual effects because plants may or may not recover over time following sublethal herbicide exposures. Therefore, it is important to assess the long-term effects of herbicide applications. Annual species rely on renewable seed production to ensure their persistence; hence, assessment of herbicide sensitivity is more accurately estimated through effects on reproduction. Here we aim to assess the phytotoxicity of two commonly used herbicides: tribenuron and 2,4-D on eight plant species belonging to four families, each with one rare and one more common species. Specifically we examined the pattern of sensitivity using short-term and long-term endpoints (total aboveground biomass, total seed biomass and number of seeds) of these species; we determined the levels of and time to recovery in terms of stem length and fruit number, and assessed whether their rarity relates to their sensitivity to herbicide application. Our results suggest that although differences in herbicide sensitivity are not a direct cause of rarity for all species, it may be an important driver of declining arable plants.
Thakur, Sahil; Ichhpujani, Parul; Kumar, Suresh; Kaur, Ravneet; Sood, Sunandan
2018-05-14
This study was designed to assess the efficacy, reliability and repeatability of SPARCS (Spaeth Richman Contrast Sensitivity Test) as compared to the conventional Pelli Robson Chart Test for the assessment of contrast sensitivity in patients with glaucoma. We evaluated 135 eyes of 135 patients who were age and sex matched into three groups (controls, disc suspects and glaucoma) of 45 patients each. The glaucoma subgroup was further divided into subgroups of mild, moderate and severe based on the visual field damage. There was a strong positive correlation between Pelli Robson scores and SPARCS scores (S = 0.807, P < 0.001). Intraclass correlation coefficient (ICC) for Pelli Robson Test was 0.952 and 0.988 for SPARCS. The coefficient of repeatability (COR) for mean SPARCS was 5.65%, while COR of Pelli Robson Test was 12.44%. SPARCS was found to have better repeatability than Pelli Robson Test based on COR values. Pelli Robson score had a sensitivity of 80% and a specificity of 65.6% for detecting glaucoma patients as compared to 84.4% and 70%, respectively, for SPARCS scores. SPARCS is a better alternative to conventional Pelli Robson Chart Test for assessment of contrast sensitivity in patients with glaucoma. Being independent of the effects of literacy and educational status, it offers a universal way to measure contrast sensitivity. It can also be reliably used in patients with varying severity of glaucoma.
Randhawa, Sharan; Walterfang, Mark; Miller, Kathryn; Scholes, Amelia; Mocellin, Ramon; Velakoulis, Dennis
2007-07-01
The carer history is an integral part of the assessment of patients with cognitive impairment. We aimed to develop a comprehensive yet concise carer questionnaire, the CogRisk, which captures actuarial risk variables for cognitive impairment in addition to key symptoms suggestive of cognitive decline in a number of cognitive domains, and to then assess its validity and reliability in a neuropsychiatric population. Carers of patients assessed for cognitive impairment completed the CogRisk, and patients were clinically assessed using the Mini-Mental State Examination (MMSE) and Neuropsychiatry Unit COGnitive assessment tool (NUCOG). Reliability was assessed using test-retest and interrater measures and measures of internal consistency. Construct and concurrent validity was assessed using correlation between total and subscale scores on the CogRisk, total scores on the NUCOG and MMSE, and subscale scores on the NUCOG. Predictive validity was determined using measures of sensitivity and specificity and using receiver operating characteristic (ROC) methods. The CogRisk was completed by all carers in less than 10 min. The total CogRisk score correlated significantly with total MMSE and NUCOG scores (r=-0.511 and -0.563, respectively) and remained highly significant when age and education were controlled for. Internal consistency of CogRisk items was high (alpha=0.943). Intrarater reliability of the CogRisk was high with an intraclass correlation coefficient of .978 (P<.001), and interrater reliability between carers was also high at 0.868 (P<.05). Sensitivity and specificity for the detection of dementia were .70 and .73, respectively, with area under the ROC curve not significantly different from that of the MMSE or NUCOG. The CogRisk is a brief carer-rated tool of a patient's cognitive functioning developed for use within a neuropsychiatric setting. It exhibited good concurrent validity, internal consistency, and interrater and intrarater reliability. The CogRisk also demonstrated good sensitivity and specificity for dementia. The CogRisk provides carer information, which complements the clinical assessment and can be used to focus on direct carer interview.
Abdrabo, Abdelkarim A; Fadlalla, Adil I; Fadl-Elmula, Imad M
2011-11-01
To assess the significance of serum total prostate specific antigen (tPSA) and digital rectal examination (DRE) in the diagnosis of prostate cancer (PC). One hundred and eighteen patients with serum tPSA ranging between 2.5 and 10 ng/ml with lower urinary tract symptoms presented at the Urology Clinic of Soba University Hospital, Khartoum, Sudan from August 2008 and January 2010 were included in the study. Serum tPSA was measured using enzyme immunoassay method, and accordingly, the patients were classified into 2 groups: patients that had tPSA between 2.5-4.0 ng/ml; and patients that had tPSA between 4.1-10 ng/ml. The DRE was performed on all patients by a qualified urologist, and were recorded as a group with suspicion of PC, and a group with no suspicion of PC. All patients underwent transrectal sextant prostate biopsy. The DRE alone showed 63.8% sensitivity and 68% specificity with 46.9% positive predictive value (PPV) for the diagnosis of PC. The tPSA test revealed 91.6% sensitivity and 24% specificity with PPV of 34%. However, when combining DRE and tPSA, the sensitivity reached 100% and the specificity increased to 92% with PPV of 49%. Combining DRE and tPSA test increases the sensitivity, specificity, and PPV of PC detection.
The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study
Jain, Nitin B.; Luz, Jennifer; Higgins, Laurence D.; Dong, Yan; Warner, Jon J.P.; Matzkin, Elizabeth; Katz, Jeffrey N.
2016-01-01
Objective The aim was to assess diagnostic accuracy of 15 shoulder special tests for rotator cuff tears. Design From 02/2011 to 12/2012, 208 participants with shoulder pain were recruited in a cohort study. Results Among tests for supraspinatus tears, Jobe’s test had a sensitivity of 88% (95% CI=80% to 96%), specificity of 62% (95% CI=53% to 71%), and likelihood ratio of 2.30 (95% CI=1.79 to 2.95). The full can test had a sensitivity of 70% (95% CI=59% to 82%) and a specificity of 81% (95% CI=74% to 88%). Among tests for infraspinatus tears, external rotation lag signs at 0° had a specificity of 98% (95% CI=96% to 100%) and a likelihood ratio of 6.06 (95% CI=1.30 to 28.33), and the Hornblower’s sign had a specificity of 96% (95% CI=93% to 100%) and likelihood ratio of 4.81 (95% CI=1.60 to 14.49). Conclusions Jobe’s test and full can test had high sensitivity and specificity for supraspinatus tears and Hornblower’s sign performed well for infraspinatus tears. In general, special tests described for subscapularis tears have high specificity but low sensitivity. These data can be used in clinical practice to diagnose rotator cuff tears and may reduce the reliance on expensive imaging. PMID:27386812
Garcia, J J; Blanca, M; Moreno, F; Vega, J M; Mayorga, C; Fernandez, J; Juarez, C; Romano, A; de Ramon, E
1997-01-01
The quantitation of in vitro IgE antibodies to the benzylpenicilloyl determinant (BPO) is a useful tool for evaluating suspected penicillin allergic subjects. Although many different methods have been employed, few studies have compared their diagnostic specificity and sensitivity. In this study, the sensitivity and specificity of three different radio allergo sorbent test (RAST) methods for quantitating specific IgE antibodies to the BPO determinant were compared. Thirty positive control sera (serum samples from penicillin allergic subjects with a positive clinical history and a positive penicillin skin test) and 30 negative control sera (sera from subjects with no history of penicillin allergy and negative skin tests) were tested for BPO-specific IgE antibodies by RAST using three different conjugates coupled to the solid phase: benzylpenicillin conjugated to polylysine (BPO-PLL), benzylpenicillin conjugated to human serum albumin (BPO-HSA), and benzylpenicillin conjugated to an aminospacer (BPO-SP). Receiver operator control curves (ROC analysis) were carried out by determining different cut-off points between positive and negative values. Contingence tables were constructed and sensitivity, specificity, negative predictive values (PV-), and positive predictive values (PV+) were calculated. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICC) were determined and the differences between methods were compared by chi 2 analysis. Analysis of the areas defined by the ROC curves showed statistical differences among the three methods. When cut-off points for optimal sensitivity and specificity were chosen, the BPO-HSA assay was less sensitive and less specific and had a lower PV- and PV+ than the BPO-PLL and BPO-SP assays. Assessment of r and ICC indicated that the correlation was very high, but the concordance between the PLL and SP methods was higher than between the PLL and HSA or SP and HSA methods. We conclude that for quantitating IgE antibodies by RAST to the BPO determinant, BPO-SP or BPO-PLL conjugates offer advantages in sensitivity and specificity compared with BPO-HSA. These results support and extend previous in vitro studies by our group and highlight the importance of the carrier for RAST assays.
ERIC Educational Resources Information Center
Grunberg, Laura
2005-01-01
Summarizing the incomplete results of the United Nations Educational and Scientific Organization (UNESCO) program "Good Practice in Promoting Gender Equality in Higher Education," the author asks that any assessment of the progress made in the area of gender-sensitive education take regional specificities into account. The regional…
Comparing approaches to screening for angle closure in older Chinese adults
Andrews, J; Chang, D S; Jiang, Y; He, M; Foster, P J; Munoz, B; Kashiwagi, K; Friedman, D S
2012-01-01
Aims Primary angle-closure glaucoma is expected to account for nearly 50% of bilateral glaucoma blindness by 2020. This study was conducted to assess the performance of the scanning peripheral anterior chamber depth analyzer (SPAC) and limbal anterior chamber depth (LACD) as screening methods for angle closure. Methods This study assessed two clinical populations to compare SPAC, LACD, and gonioscopy: the Zhongshan Angle-closure Prevention Trial, from which 370 patients were eligible as closed-angle participants and the Liwan Eye Study, from which 72 patients were selected as open-angle controls. Eligible participants were assessed by SPAC, LACD, and gonioscopy. Results Angle status was defined by gonioscopy. Area under the receiver operating characteristic curve (AUROC) for SPAC was 0.92 (0.89–0.95) whereas AUROC for LACD was 0.94 (0.92–0.97). Using conventional cutoff points, sensitivity/specificity was 93.0%/70.8% for SPAC and 94.1%/87.5% for LACD. Sequential testing using both SPAC and LACD increased the specificity to 94.4% and decreased the sensitivity to 87.0%. Conclusion SPAC has significantly lower specificity than LACD measurement using conventional cutoffs but interpretation of the findings can be performed by modestly trained personnel. PMID:21997356
Good modeling practice guidelines for applying multimedia models in chemical assessments.
Buser, Andreas M; MacLeod, Matthew; Scheringer, Martin; Mackay, Don; Bonnell, Mark; Russell, Mark H; DePinto, Joseph V; Hungerbühler, Konrad
2012-10-01
Multimedia mass balance models of chemical fate in the environment have been used for over 3 decades in a regulatory context to assist decision making. As these models become more comprehensive, reliable, and accepted, there is a need to recognize and adopt principles of Good Modeling Practice (GMP) to ensure that multimedia models are applied with transparency and adherence to accepted scientific principles. We propose and discuss 6 principles of GMP for applying existing multimedia models in a decision-making context, namely 1) specification of the goals of the model assessment, 2) specification of the model used, 3) specification of the input data, 4) specification of the output data, 5) conduct of a sensitivity and possibly also uncertainty analysis, and finally 6) specification of the limitations and limits of applicability of the analysis. These principles are justified and discussed with a view to enhancing the transparency and quality of model-based assessments. Copyright © 2012 SETAC.
The diagnosis of food allergy: a systematic review and meta-analysis.
Soares-Weiser, K; Takwoingi, Y; Panesar, S S; Muraro, A; Werfel, T; Hoffmann-Sommergruber, K; Roberts, G; Halken, S; Poulsen, L; van Ree, R; Vlieg-Boerstra, B J; Sheikh, A
2014-01-01
We investigated the accuracy of tests used to diagnose food allergy. Skin prick tests (SPT), specific-IgE (sIgE), component-resolved diagnosis and the atopy patch test (APT) were compared with the reference standard of double-blind placebo-controlled food challenge. Seven databases were searched and international experts were contacted. Two reviewers independently identified studies, extracted data, and used QUADAS-2 to assess risk of bias. Where possible, meta-analysis was undertaken. Twenty-four (2831 participants) studies were included. For cows' milk allergy, the pooled sensitivities were 53% (95% CI 33-72), 88% (95 % CI 76-94), and 87% (95% CI 75-94), and specificities were 88% (95% CI 76-95), 68% (95% CI 56-77), and 48% (95% CI 36-59) for APT, SPT, and sIgE, respectively. For egg, pooled sensitivities were 92% (95% CI 80-97) and 93% (95% CI 82-98), and specificities were 58% (95% CI 49-67) and 49% (40-58%) for skin prick tests and specific-IgE. For wheat, pooled sensitivities were 73% (95% CI 56-85) and 83% (95% CI 69-92), and specificities were 73% (95% CI 48-89) and 43% (95% CI 20-69%) for SPT and sIgE. For soy, pooled sensitivities were 55% (95% CI 33-75) and 83% (95% CI 64-93), and specificities were 68% (95% CI 52-80) and 38% (95% CI 24-54) for SPT and sIgE. For peanut, pooled sensitivities were 95% (95% CI 88-98) and 96% (95% CI 92-98), and specificities were 61% (95% CI 47-74), and 59% (95% CI 45-72) for SPT and sIgE. The evidence base is limited and weak and is therefore difficult to interpret. Overall, SPT and sIgE appear sensitive although not specific for diagnosing IgE-mediated food allergy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Importance of albumin in cross-reactivity among cat, dog and horse allergens.
Cabañas, R; López-Serrano, M C; Carreira, J; Ventas, P; Polo, F; Caballero, M T; Contreras, J; Barranco, P; Moreno-Ancillo, A
2000-01-01
Different allergenic proteins have been involved in cross-reactivity among animals. Albumins seem to be cross-sensitizing allergenic components. The aim of this study was to assess the importance of albumin as a cross-reactive allergen in patients sensitized to cat, dog and horse. One hundred and seventeen patients sensitized to cat were tested for IgE reactivity using skin prick tests and RAST assays with cat, dog and horse hair/dander extracts and their purified albumin extracts. RAST-inhibition studies were carried out to assess cross-reactivity among cat, dog and horse and among their purified albumins. It was found that 22% of patients exhibited specific IgE to cat albumin; 41% of patients sensitized to cat were also sensitized to dog and horse. Out of these patients, 21% had IgE to three albumins and 17% to two. Reciprocal inhibitions were observed among cat, dog and horse albumins and also among cat, dog and horse hair/dander extracts, using in the latter experiment sera from patients not sensitized to albumins. IgE binding to horse extract was inhibited 30% by its homologous albumin and IgE binding to cat and dog extracts in almost 15% by their respective albumins. It was concluded that albumins from these three animals share some epitopes that account for the cross-reactivity observed in around one-third of patients sensitized to cat, dog and horse. Nevertheless, more than 50% of specific IgE that cross-reacts among these three animals is directed to allergens other than albumin.
Bowsher, R R; Compton, J A; Kirkwood, J A; Place, G D; Jones, C D; Mabry, T E; Hyslop, D L; Hatcher, B L; DeSante, K A
1994-01-01
Fialuridine (FIAU) is a halogen-substituted analog of thymidine that was undergoing clinical investigation as a drug for the treatment of chronic hepatitis B viral infection. However, clinical trials of FIAU were terminated after adverse events occurred following chronic oral administration. Prior to the termination of clinical trials, a sensitive assay was needed for the measurement of FIAU because of the anticipated low dose administered to patients. We therefore undertook the development of a radioimmunoassay (RIA). A specific antiserum was raised in rabbits following immunization with a 5'-O-hemisuccinate analog of FIAU coupled to keyhole limpet hemocyanin. Radiolabeled FIAU was synthesized by a destannylation procedure by using sodium [125I]iodide. We developed a competitive-binding procedure and used precipitation with polyethylene glycol as the method for separating the bound and free forms of FIAU. The RIA is sensitive (0.2 ng/ml), specific (negligible interference from known metabolites and endogenous nucleosides), and reproducible (interassay coefficients of variation range from 5 to 19.7% for serum controls). We used the RIA to assess the pharmacokinetics of FIAU in healthy adult volunteers following administration of a single 5-mg oral dose. The sensitivity of the RIA permitted the detection of a prolonged elimination phase for FIAU in healthy volunteers and dogs, with mean elimination half-lives of 29.3 and 35.3 h, respectively. We conclude the RIA is a valid method for the quantification of FIAU in biological fluids. PMID:7811032
Severe community-acquired pneumonia. Assessment of severity criteria.
Ewig, S; Ruiz, M; Mensa, J; Marcos, M A; Martinez, J A; Arancibia, F; Niederman, M S; Torres, A
1998-10-01
The purpose of the study was to validate the criteria used in the guidelines of the American Thoracic Society (ATS) for severe community-acquired pneumonia (CAP). Severe pneumonia was defined as admission to the intensive care unit (ICU). Overall 331 nonsevere (84%) and 64 severe cases (16%) of CAP were prospectively studied. Mortality was 19 of 395 (5%) and 19 of 64 (30%), respectively. Single severity criteria as well as the ATS definition of severe pneumonia were assessed calculating the operative indices. A modified prediction rule including minor (baseline) and major (baseline or evolutionary) criteria was derived. Single minor criteria at admission had a low sensitivity and positive predictive value. Defining severe pneumonia according to the ATS guidelines had a high sensitivity (98%). However, specificity and positive predictive value were low (32% and 24%, respectively). A modified prediction rule (presence of two or three minor criteria [systolic blood pressure < 90 mm Hg, multilobar involvement, PaO2/FIO2 < 250] or one of two major criteria [requirement of mechanical ventilation, presence of septic shock]) had a sensitivity of 78%, a specificity of 94%, a positive predictive value of 75%, and a negative predictive value of 95%. The ATS definition of severe pneumonia was highly sensitive but insufficiently specific and had a low positive predictive value. Our suggested modified rule had a more balanced performance and, if validated in an independent population, may represent a more accurate definition of severe CAP.
Iuzzini-Seigel, Jenya; Hogan, Tiffany P; Green, Jordan R
2017-05-24
The current research sought to determine (a) if speech inconsistency is a core feature of childhood apraxia of speech (CAS) or if it is driven by comorbid language impairment that affects a large subset of children with CAS and (b) if speech inconsistency is a sensitive and specific diagnostic marker that can differentiate between CAS and speech delay. Participants included 48 children ranging between 4;7 to 17;8 (years;months) with CAS (n = 10), CAS + language impairment (n = 10), speech delay (n = 10), language impairment (n = 9), or typical development (n = 9). Speech inconsistency was assessed at phonemic and token-to-token levels using a variety of stimuli. Children with CAS and CAS + language impairment performed equivalently on all inconsistency assessments. Children with language impairment evidenced high levels of speech inconsistency on the phrase "buy Bobby a puppy." Token-to-token inconsistency of monosyllabic words and the phrase "buy Bobby a puppy" was sensitive and specific in differentiating children with CAS and speech delay, whereas inconsistency calculated on other stimuli (e.g., multisyllabic words) was less efficacious in differentiating between these disorders. Speech inconsistency is a core feature of CAS and is efficacious in differentiating between children with CAS and speech delay; however, sensitivity and specificity are stimuli dependent.
Identification of the need for home visiting nurse: development of a new assessment tool
Taguchi, Atsuko; Nagata, Satoko; Naruse, Takashi; Kuwahara, Yuki; Yamaguchi, Takuhiro; Murashima, Sachiyo
2014-01-01
Objective To develop a Home Visiting Nursing Service Need Assessment Form (HVNS-NAF) to standardize the decision about the need for home visiting nursing service. Methods The sample consisted of older adults who had received coordinated services by care managers. We defined the need for home visiting nursing service by elderly individuals as the decision of the need by a care manager so that the elderly can continue to live independently. Explanatory variables included demographic factors, medical procedure, severity of illness, and caregiver variables. Multiple logistic regression was carried out after univariate analyses to decide the variables to include and the weight of each variable in the HVNS-NAF. We then calculated the sensitivity and specificity of each cutoff value, and defined the score with the highest sensitivity and specificity as the cutoff value. Results Nineteen items were included in the final HVNS-NAF. When the cutoff value was 2 points, the sensitivity was 77.0%, specificity 68.5%, and positive predictive value 56.8%. Conclusions HVNS-NAF is the first validated standard based on characteristics of elderly clients who required home visiting nursing service. Using the HVNS-NAF may result in reducing the unmet need for home visiting nursing service and preventing hospitalization. PMID:24665229
Diagnosis of breast cancer using elastic-scattering spectroscopy: preliminary clinical results
NASA Astrophysics Data System (ADS)
Bigio, Irving J.; Brown, Stephen G.; Briggs, Gavin M.; Kelley, Christine; Lakhani, Sunil; Pickard, David; Ripley, Paul M.; Rose, Ian; Saunders, Christobel
2000-04-01
We report on the first stages of a clinical study designed to test elastic-scattering spectroscopy, medicated by fiberoptic probes, for three specific clinical applications in breast-tissue diagnosis: (1) a transdermal-needle (interstitial) measurement for instant diagnosis with minimal invasiveness similar to fine-needle aspiration but with sensitivity to a larger tissue volume, (2) a hand-held diagnostic probe for use in assessing tumor/resection margins during open surgery, and (3) use of the same probe for real-time assessment of the `sentinel' node during surgery to determine the presence or absence of tumor (metastatic). Preliminary results from in vivo measurements on 31 women are encouraging. Optical spectra were measured on 72 histology sites in breast tissue, and 54 histology sites in sentinel nodes. Two different artificial intelligence methods of spectral classification were studied. Artificial neural networks yielded sensitivities of 69% and 58%, and specificities of 85% and 93%, for breast tissue and sentinel nodes, respectively. Hierarchical cluster analysis yielded sensitivities of 67% and 91%, and specificities of 79% and 77%, for breast tissue and sentinel nodes, respectively. These values are expected to improve as the data sets continue to grow and more sophisticated data preprocessing is employed. The study will enroll up to 400 patients over the next two years.
The Diagnostic Value of Gastrin-17 Detection in Atrophic Gastritis
Wang, Xu; Ling, Li; Li, Shanshan; Qin, Guiping; Cui, Wei; Li, Xiang; Ni, Hong
2016-01-01
Abstract A meta-analysis was performed to assess the diagnostic value of gastrin-17 (G-17) for the early detection of chronic atrophic gastritis (CAG). An extensive literature search was performed, with the aim of selecting publications that reported the accuracy of G-17 in predicting CAG, in the following databases: PubMed, Science Direct, Web of Science, Chinese Biological Medicine, Chinese National Knowledge Infrastructure, Wanfang, and VIP. To assess the diagnostic value of G-17, the following statistics were estimated and described: sensitivity, specificity, diagnostic odds ratios (DOR), summary receiver operating characteristic curves, area under the curve (AUC), and 95% confidence intervals (CIs). Thirteen studies that met the inclusion criteria were included in this meta-analysis, comprising 894 patients and 1950 controls. The pooled sensitivity and specificity of these studies were 0.48 (95% CI: 0.45–0.51) and 0.79 (95% CI: 0.77–0.81), respectively. The DOR was 5.93 (95% CI: 2.93–11.99), and the AUC was 0.82. G-17 may have potential diagnostic value because it has good specificity and a moderate DOR and AUC for CAG. However, more studies are needed to improve the sensitivity of this diagnostic tool in the future. PMID:27149493
Bustos, Javier A; García, Hector H; Del Brutto, Oscar H
2017-09-01
Intraventricular neurocysticercosis (NCC) is a severe form of NCC requiring prompt diagnosis and treatment. We aimed to assess the reliability of the most recent version of diagnostic criteria for this form of NCC. Two systematic literature reviews were performed; one included case reports of patients with intraventricular cysticercosis and the other included case reports of patients with intraventricular cystic lesions or granulomas caused by infections other than NCC. All assessed cases were categorized according to the last revision of the long-standing Del Brutto's set of diagnostic criteria to determine its sensitivity, specificity, and predictive value for this form of NCC. The search disclosed 128 patients with intraventricular NCC and 41 with other infections. The set of diagnostic criteria classified as definitive NCC 93 cases with intraventricular NCC (sensitivity 72.7%, 95% CI, 63.9-79.9%), as well as four cases with other infections (specificity 90.2%, 95% CI, 75.9-96.8%). The positive and negative predictive values of the criteria were 0.96 (95% CI, 0.89-0.99) and 0.51 (95% CI, 0.39-0.63), respectively. The revised Del Brutto's set of diagnostic criteria for NCC is acceptably sensitive and highly specific for diagnosing patients with the ventricular form of the disease.
The panic disorder screener (PADIS): Development of an accurate and brief population screening tool.
Batterham, Philip J; Mackinnon, Andrew J; Christensen, Helen
2015-07-30
The Panic Disorder Screener (PADIS) was developed as a new screener to identify panic disorder in the community and to assess severity of symptoms. The PADIS was developed to fill a gap in existing screening measures, as there are no brief panic screeners available that assess severity. The current study aimed to test the performance of the screener relative to the Patient Health Questionnaire-panic scale (PHQ-panic). The 4-item PADIS was administered to 12,336 young Australian adults, together with the PHQ-panic. A subsample of 1674 participants also completed a phone-based clinical interview to determine whether they met DSM-IV criteria for panic disorder. The PADIS (77% sensitivity, 84% specificity) had higher sensitivity for identifying panic disorder based on clinical criteria than the PHQ-panic (57% sensitivity, 91% specificity), although with reduced specificity. Administration of the PADIS required a mean of 1.9 items, compared to 4.7 items for the PHQ-panic. Each one-point increase in PADIS score was associated with 69% increased odds of meeting clinical criteria for panic disorder. The PADIS was found to be a valid, reliable and brief panic screener that is freely available for use in research and clinical settings. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Zheng, Jun; Yu, Zhiyuan; Guo, Rui; Li, Hao; You, Chao; Ma, Lu
2018-04-27
Hematoma expansion is related to unfavorable prognosis in intracerebral hemorrhage (ICH). The black hole sign is a novel marker on non-contrast computed tomography for predicting hematoma expansion. However, its predictive values are different in previous studies. Thus, this meta-analysis was conducted to evaluate the predictive significance of the black hole sign for hematoma expansion in ICH. A systematic literature search was performed. Original researches on the association between the black hole sign and hematoma expansion in ICH were included. Sensitivity and specificity were pooled to assess the predictive accuracy. Summary receiver operating characteristics curve (SROC) was developed. Deeks' funnel plot asymmetry test was used to assess the publication bias. Five studies with a total of 1495 patients were included in this study. The pooled sensitivity and specificity of the black hole sign for predicting hematoma expansion were 0.30 and 0.91, respectively. The area under the curve was 0.78 in SROC curve. There was no significant publication bias. This meta-analysis shows that the black hole sign is a helpful imaging marker for predicting hematoma expansion in ICH. Although the black hole sign has a relatively low sensitivity, its specificity is relatively high. Copyright © 2018 Elsevier Inc. All rights reserved.
Mossman, Sarah A; Luft, Marissa J; Schroeder, Heidi K; Varney, Sara T; Fleck, David E; Barzman, Drew H; Gilman, Richard; DelBello, Melissa P; Strawn, Jeffrey R
2017-11-01
In pediatric patients with anxiety disorders, existing symptom inventories are either not freely available or require extensive time and effort to administer. We sought to evaluate a brief self-report scale-the Generalized Anxiety Disorder 7-item scale (GAD-7)-in adolescents with generalized anxiety disorder (GAD). The Pediatric Anxiety Rating Scale (PARS) and the GAD-7 were administered to youth with GAD (confirmed by structured interview). Relationships between the measures were assessed, and sensitivity and specificity was determined with regard to a global symptom severity measure (Clinical Global Impression-Severity). In adolescents with GAD (N = 40; mean age, 14.8 ± 2.8), PARS and GAD-7 scores strongly correlated (R = 0.65, P ≤ .001) and a main effect for symptom severity was observed (P ≤ .001). GAD-7 scores ≥11 and ≥17 represented the optimum specificity and sensitivity for detecting moderate and severe anxiety, respectively. The PARS and GAD-7 similarly reflect symptom severity. The GAD-7 is associated with acceptable specificity and sensitivity for detecting clinically significant anxiety symptoms. GAD-7 scores may be used to assess anxiety symptoms and to differentiate between mild and moderate GAD in adolescents, and may be more efficient than the PARS.
Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.
Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu
2017-09-01
The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Schueler, Sabine; Walther, Stefan; Schuetz, Georg M; Schlattmann, Peter; Dewey, Marc
2013-06-01
To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.
Custodio, Nilton; Lira, David; Herrera-Perez, Eder; Montesinos, Rosa; Castro-Suarez, Sheila; Cuenca-Alfaro, José; Valeriano-Lorenzo, Lucía
2017-01-01
Background/Aims : Short tests to early detection of the cognitive impairment are necessary in primary care setting, particularly in populations with low educational level. The aim of this study was to assess the performance of Memory Alteration Test (M@T) to discriminate controls, patients with amnestic Mild Cognitive Impairment (aMCI) and patients with early Alzheimer's Dementia (AD) in a sample of individuals with low level of education. Methods : Cross-sectional study to assess the performance of the M@T (study test), compared to the neuropsychological evaluation (gold standard test) scores in 247 elderly subjects with low education level from Lima-Peru. The cognitive evaluation included three sequential stages: (1) screening (to detect cases with cognitive impairment); (2) nosological diagnosis (to determinate specific disease); and (3) classification (to differentiate disease subtypes). The subjects with negative results for all stages were considered as cognitively normal (controls). The test performance was assessed by means of area under the receiver operating characteristic (ROC) curve. We calculated validity measures (sensitivity, specificity and correctly classified percentage), the internal consistency (Cronbach's alpha coefficient), and concurrent validity (Pearson's ratio coefficient between the M@T and Clinical Dementia Rating (CDR) scores). Results : The Cronbach's alpha coefficient was 0.79 and Pearson's ratio coefficient was 0.79 ( p < 0.01). The AUC of M@T to discriminate between early AD and aMCI was 99.60% (sensitivity = 100.00%, specificity = 97.53% and correctly classified = 98.41%) and to discriminate between aMCI and controls was 99.56% (sensitivity = 99.17%, specificity = 91.11%, and correctly classified = 96.99%). Conclusions : The M@T is a short test with a good performance to discriminate controls, aMCI and early AD in individuals with low level of education from urban settings.
Mahe, Guillaume; Liedl, David A; McCarter, Charlene; Shepherd, Roger; Gloviczki, Peter; McPhail, Ian R; Rooke, Thom W; Wennberg, Paul W
2014-04-01
This study was conducted to determine the sensitivity and specificity of laser Doppler flowmetry (LDF) measurements for digital obstructive arterial disease (DOAD) using angiography as the reference standard and to compare the accuracy of different classical tests used to assess DOAD. Diagnosis of vascular abnormalities at the digital level is challenging. Angiography is the gold standard for assessment of DOAD but is invasive and expensive to perform. We performed a retrospective analysis of consecutive patients referred at Mayo Clinic (Rochester, Minn) for upper extremity arterial assessment during a 27-month period. Finger-brachial index, skin blood flow (in arbitrary units [a.u.]), and skin temperature (in degrees Celsius) were recorded in each digit on the pulp at baseline and after a thermal challenge test (hand placed in a thermal box at 47.0°C for 15 minutes). Angiogram analysis was blinded and performed by a radiologist using a vascularization scale ranging from 0 (no vessel) to 4 (normal). The receiver operating characteristic curve was used to define a specific cutoff point to detect DOAD. Twenty-two patients had LDF measurements and complete angiograms. A total of 185 digits were analyzed because some patients had only analysis of one hand. The best area under the curve (AUC) was 0.98 (range, 0.94-0.99) for postwarming skin blood flow, with a cutoff point of ≤206 a.u. This AUC was statistically different from AUCs of all the other tests (P < .01). Sensitivity and specificity were 93% (95% confidence interval, 85%-97%) and 96% (95% confidence interval, 90%-99%), respectively. LDF combined with a thermal challenge is highly accurate, safe, and noninvasive means to detect DOAD. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Kee, C C; Jamaiyah, H; Geeta, A; Ali, Z Ahmad; Safiza, M N Noor; Suzana, S; Khor, G L; Rahmah, R; Jamalludin, A R; Sumarni, M G; Lim, K H; Faudzi, Y Ahmad; Amal, N M
2011-12-01
Generalised obesity and central obesity are risk factors for Type II diabetes mellitus and cardiovascular diseases. Waist circumference (WC) has been suggested as a single screening tool for identification of overweight or obese subjects in lieu of the body mass index (BMI) for weight management in public health program. Currently, the recommended waist circumference cut-off points of > or = 94cm for men and > or =80cm for women (waist action level 1) and > or = 102cm for men and > or = 88cm for women (waist action level 2) used for identification of overweight and obesity are based on studies in Caucasian populations. The objective of this study was to assess the sensitivity and specificity of the recommended waist action levels, and to determine optimal WC cut-off points for identification of overweight or obesity with central fat distribution based on BMI for Malaysian adults. Data from 32,773 subjects (14,982 men and 17,791 women) aged 18 and above who participated in the Third National Health Morbidity Survey in 2006 were analysed. Sensitivity and specificity of WC at waist action level 1 were 48.3% and 97.5% for men; and 84.2% and 80.6% for women when compared to the cut-off points based on BMI > or = 25kg/m2. At waist action level 2, sensitivity and specificity were 52.4% and 98.0% for men, and 79.2% and 85.4% for women when compared with the cut-off points based on BMI (> or = 30 kg/m2). Receiver operating characteristic analyses showed that the appropriatescreening cut-off points for WC to identify subjects with overweight (> or = 25kg/m2) was 86.0cm (sensitivity=83.6%, specificity=82.5%) for men, and 79.1cm (sensitivity=85.0%, specificity=79.5%) for women. Waist circumference cut-off points to identify obese subjects (BMI > or = 30 kg/m2) was 93.2cm (sensitivity=86.5%, specificity=85.7%) for men and 85.2cm (sensitivity=77.9%, specificity=78.0%) for women. Our findings demonstrated that the current recommended waist circumference cut-off points have low sensitivity for identification of overweight and obesity in men. We suggest that these newly identified cut-off points be considered.
Adamowski, Tomasz; Kiejna, Andrzej; Hadryś, Tomasz
2006-01-01
Authors aimed at testing whether psychiatrists in their diagnostic process obeyed strict ICD-10 diagnostic criteria. Diagnoses made by psychiatrists at discharge were compared with those of SCAN ver.2.1 on admission. Diagnoses obtained by SCAN I-Shell program were compared with clinical diagnoses obtained by psychiatrists in the psychiatric wards according to ICD-10 criteria on 3 levels: diagnostic group (Fc), diagnostic class (Fcc), and diagnostic category (Fcc.c). Validity assessment was obtained with Cohen's Kappa coefficient, sensitivity, specificity and Yule's Y coefficient. On the diagnostic group level, Cohen's kappa was 0.14-0.65, Yule's Y 0.57-0.71. Sensitivity 0.69-0.95 and specificity 0.41-0.94. In psychotic disorders group F2 kappa was 0.65, Yule's Y 0.71, sensitivity 0.69, specificity 0.94. In affective disorders group F3 kappa was 0.31, Yule's Y 0.57, sensitivity 0.95, specificity 0.41. In neurotic disorders group F4 kappa was low 0.14, Yule's Y 0.62, sensitivity 0.95, specificity 0.50. The study showed a higher level of agreement between SCAN and clinical diagnoses in the group of psychotic disorders with exception of schizoaffective disorders, and lower agreement rates in the group of affective and neurotic disorders where the number of SCAN diagnoses outweighed that of the clinical ones. It could be the result of systematic faults in the coding of diagnoses.
Diagnostic value of sputum adenosine deaminase (ADA) level in pulmonary tuberculosis.
Binesh, Fariba; Jalali, Hadi; Zare, Mohammad Reza; Behravan, Farhad; Tafti, Arefeh Dehghani; Behnaz, Fatemah; Tabatabaee, Mohammad; Shahcheraghi, Seyed Hossein
2016-06-01
Tuberculosis is still a considerable health problem in many countries. Rapid diagnosis of this disease is important, and adenosine deaminase (ADA) has been used as a diagnostic test. The aim of this study was to assess the diagnostic value of ADA in the sputum of patients with pulmonary tuberculosis. The current study included 40 patients with pulmonary tuberculosis (culture positive, smear ±) and 42 patients with non tuberculosis pulmonary diseases (culture negative). ADA was measured on all of the samples. The median value of ADA in non-tuberculosis patients was 2.94 (4.2) U/L and 4.01 (6.54) U/L in tuberculosis patients, but this difference was not statistically significant (p=0.100). The cut-off point of 3.1 U/L had a sensitivity of 61% and a specificity of 53%, the cut-off point of 2.81 U/L had a sensitivity of 64% and a specificity of 50% and the cut-off point of 2.78 U/L had a sensitivity of 65% and a specificity of 48%. The positive predictive values for cut-off points of 3.1, 2.81 and 2.78 U/L were 55.7%, 57.44% and 69.23%, respectively. The negative predictive values for the abovementioned cut-off points were 56.75%, 57.14% and 55.88%, respectively. Our results showed that sputum ADA test is neither specific nor sensitive. Because of its low sensitivity and specificity, determination of sputum ADA for the diagnosis of pulmonary tuberculosis is not recommended.
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-10-13
The diagnostic values of diffusion weighted imaging (DWI) and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73-0.85), 0.69 (0.61-0.77), and 0.81 (0.77-0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39-0.64), 0.88 (0.61-0.97), and 0.66 (0.62-0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18 F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18 F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18 F-FDG PET/CT had limited utility for preoperative N-staging.
Ripollés, Tomás; Martínez-Pérez, María Jesús; Gómez Valencia, Diana Patricia; Vizuete, José; Martín, Gregorio
2015-10-01
To retrospectively evaluate the accuracy of ultrasound as a diagnostic method for differentiating acute diverticulitis from colon cancer in patients with sigmoid colon stenosis. Ultrasound examinations of 91 consecutive patients with sigmoid stenosis (50 diverticulitis and 41 colon cancers) were reviewed by two trained radiologists. Sixty-five (71%) patients presented with acute abdominal symptoms. Thirteen sonographic criteria retrieved from the literature were evaluated to differentiate benign from malignant strictures. A score including all parameters which showed significant differences between benign vs. malignant was built. Sensitivity, specificity, accuracy, and positive or negative predictive values of each sonographic sign, the overall diagnosis, and sonographic score were calculated. Loss of the bowel wall stratification was the most reliable criteria for the diagnosis of malignancy (92% and 94% of sensitivity and specificity, respectively), and the best inter-radiologist agreement (κ = 0.848). Adjacent lymph nodes were the most specific feature (98%) for colon cancer, but its sensitivity was low. Global assessment could differentiate both diseases with high sensitivity (92-94.9%) and specificity (98-100%). Sonographic score >3 enabled differentiation of carcinoma from diverticulitis with 95% sensitivity and 92-94% specificity, with an area under the ROC curve of 0.98-0.987. There were no significant differences in the results between patients with acute and nonacute abdominal symptoms. The combination of several morphological sonographic findings using a score can differentiate most cases of diverticulitis from colon carcinoma in sigmoid strictures.
Ecotoxicity of boric acid in standard laboratory tests with plants and soil organisms.
Princz, Juliska; Becker, Leonie; Scheffczyk, Adam; Stephenson, Gladys; Scroggins, Rick; Moser, Thomas; Römbke, Jörg
2017-05-01
To verify the continuous sensitivity of ecotoxicological tests (mainly the test organisms), reference substances with known toxicity are regularly tested. Ideally, this substance(s) would lack specificity in its mode action, be bioavailable and readily attainable with cost-effective means of chemical characterization. Boric acid has satisfied these criteria, but has most recently been characterized as a substance of very high concern, due to reproductive effects in humans, thus limiting its recommendation as an ideal reference toxicant. However, there is probably no other chemical for which ecotoxicity in soil has been so intensively studied; an extensive literature review yielded lethal (including avoidance) and sublethal data for 38 taxa. The ecotoxicity data were evaluated using species sensitivity distributions, collectively across all taxa, and separately according to species type, endpoints, soil type and duration. The lack of specificity in the mode of action yielded broad toxicity among soil taxa and soil types, and provided a collective approach to assessing species sensitivity, while taking into consideration differences in test methodologies and exposure durations. Toxicity was species-specific with Folsomia candida and enchytraied species demonstrating the most sensitivity; among plants, the following trend occurred: dicotyledonous (more sensitive) ≫ monocotyledonous ≫ gymnosperm species. Sensitivity was also time and endpoint specific, with endpoints such as lethality and avoidance being less sensitive than reproduction effects. Furthermore, given the breadth of data and toxicity demonstrated by boric acid, lessons learned from its evaluation are discussed to recommend the properties required by an ideal reference substance for the soil compartment.
NASA Astrophysics Data System (ADS)
Fitriani, C. L.; Panggabean, M.; Pasaribu, A. P.
2018-03-01
Soil-transmitted helminths (STH) or a group of parasitic nematode worms causing human infection through contact with moist soil may contribute to anemia, nutritional disorders, physical and intellectual growth retardation. School-age children are at high risk of STH infection due to frequent contact with soil. Reliable, sensitive, and practical diagnostic are the test series for detecting STH. This study aimed to assess the sensitivity and specificity of the formol-ether concentration (FEC) in the diagnosis of STH when compared to the Kato-Katz technique. The study was designed at state elementary school 27 Peusangan, Bireuen. The FEC study on a total of 80 (100%) elementary students showed that 12 (15%) sample had the STH infection, while Kato-Katz technique (Gold standard) showed that 31 (38.75%) sample had the STH infection. The FEC technique has the sensitivity of (38.71%), specificity of (100%) and accuracy of (76.25%). The Kato-Katz technique is better than the FEC technique for assessing STH in Bireuen due to mild infection.
Castellanos-Ryan, Natalie; O'Leary-Barrett, Maeve; Sully, Laura; Conrod, Patricia
2013-01-01
This study assessed the validity, sensitivity, and specificity of the Substance Use Risk Profile Scale (SURPS), a measure of personality risk factors for substance use and other behavioral problems in adolescence. The concurrent and predictive validity of the SURPS was tested in a sample of 1,162 adolescents (mean age: 13.7 years) using linear and logistic regressions, while its sensitivity and specificity were examined using the receiver operating characteristics curve analyses. Concurrent and predictive validity tests showed that all 4 brief scales-hopelessness (H), anxiety sensitivity (AS), impulsivity (IMP), and sensation seeking (SS)-were related, in theoretically expected ways, to measures of substance use and other behavioral and emotional problems. Results also showed that when using the 4 SURPS subscales to identify adolescents "at risk," one can identify a high number of those who developed problems (high sensitivity scores ranging from 72 to 91%). And, as predicted, because each scale is related to specific substance and mental health problems, good specificity was obtained when using the individual personality subscales (e.g., most adolescents identified at high risk by the IMP scale developed conduct or drug use problems within the next 18 months [a high specificity score of 70 to 80%]). The SURPS is a valuable tool for identifying adolescents at high risk for substance misuse and other emotional and behavioral problems. Implications of findings for the use of this measure in future research and prevention interventions are discussed. Copyright © 2012 by the Research Society on Alcoholism.
Comparison of five diagnostic tests for Giardia duodenalis in fecal samples from young dogs.
Uehlinger, Fabienne D; Naqvi, S Ali; Greenwood, Spencer J; McClure, J Trenton; Conboy, Gary; O'Handley, Ryan; Barkema, Herman W
2017-09-15
Five diagnostic tests were compared for the diagnosis of Giardia duodenalis in fecal samples of young dogs. Fecal samples were collected from 136 healthy dogs <1year old and examined using immunofluorescence antibody microscopy (IFA) after sucrose gradient centrifugation, zinc sulfate centrifugal flotation technique (ZSCT), SNAP ® Giardia test, and ProSpecT ® Giardia EZ Microplate assay. In addition, polymerase chain reaction (PCR) of the 16S rRNA gene was performed. Kappa (κ) statistic was calculated to assess diagnostic agreement between the IFA and each test. Using the IFA as the gold standard, the relative sensitivity and specificity of each test were determined. Subsequently, a Bayesian approach was used to estimate the sensitivity and specificity of each test in comparison to the IFA results. Giardia duodenalis was detected in 41% of the samples examined by IFA. The ZSCT resulted in 37% of positive samples, with a relative sensitivity and specificity of 86 and 98%, respectively. The SNAP ® Giardia test was positive in 40% of the samples, with a relative sensitivity and specificity of 91 and 96%, respectively. The ProSpecT ® test was positive in 51% of the samples, with a relative sensitivity and specificity of 100 and 83%, respectively. The relative sensitivity and specificity for PCR were 58 and 56%, respectively, with 55% of samples being PCR-positive. While the sensitivity and specificity estimates of each test in comparison to the IFA changed when using a Bayesian approach, the conclusions remained the same. While the ProSpecT ® test was the most sensitive test in this study, it is not designed for dogs and more costly than the other tests. The SNAP ® Giardia test performed similar to the ZSCT but may be more favorable because it is fast and easy to perform. Performance of the PCR was poor and the benefit of PCR may be in determining genotypes for evaluating zoonotic transfer between dogs and humans. Copyright © 2017 Elsevier B.V. All rights reserved.
Ramlall, S; Chipps, J; Bhigjee, A I; Pillay, B J
2013-01-01
The effectiveness of dementia screening depends on the availability of suitable screening tools with good sensitivity and specificity to confidently distinguish normal age-related cognitive decline from dementia. The aim of this study was to evaluate the discriminant validity of 7 screening measures for dementia. A sample of 140 participants aged ≥60 years living in a residential facility for the aged were assessed clinically and assigned caseness for dementia using the Diagnostic and Statistical Manual of Mental Disorders, 4th edition, text revised diagnostic criteria. Sensitivity and specificity of a selection of the following screening measures were tested using receiver operating characteristic (ROC) analysis for individual and combined tests: the Mini-Mental State Examination (MMSE), Six-Item Screener (SIS), Subjective Memory Complaint, Subjective Memory Complaint Clinical (SMCC), Subjective Memory Rating Scale (SMRS), Deterioration Cognitive Observee (DECO) and the Clock Drawing Test (CDT). Using ROC analyses, the SMCC, MMSE and CDT were found to be 'moderately accurate' in screening for dementia with an area under the curve (AUC) >0.70. The AUCs for the SIS (0.526), SMRS (0.661) and DECO (0.687) classified these measures as being 'less accurate'. At recommended cutoff scores, the SMCC had a sensitivity of 90.9% and specificity of 45.7%; the MMSE had a sensitivity of 63.6% and a specificity of 76.0%, and the CDT had a sensitivity of 44.4% and a specificity of 88.9%. Combining the SMCC and MMSE did not improve their predictive power except for a modest increase when using the sequential rule. The SMCC is composed of valid screening questions that have high sensitivity, are simple to administer and ideal for administration at the community or primary health care level as a first level of 'rule-out' screening. The MMSE can be included at a second stage of screening at the general hospital level and the CDT in specialist clinical settings. Sequential use of the SMCC and MMSE will improve the specificity of the former and the sensitivity of the latter. Copyright © 2013 S. Karger AG, Basel.
TSUNAMI Primer: A Primer for Sensitivity/Uncertainty Calculations with SCALE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rearden, Bradley T; Mueller, Don; Bowman, Stephen M
2009-01-01
This primer presents examples in the application of the SCALE/TSUNAMI tools to generate k{sub eff} sensitivity data for one- and three-dimensional models using TSUNAMI-1D and -3D and to examine uncertainties in the computed k{sub eff} values due to uncertainties in the cross-section data used in their calculation. The proper use of unit cell data and need for confirming the appropriate selection of input parameters through direct perturbations are described. The uses of sensitivity and uncertainty data to identify and rank potential sources of computational bias in an application system and TSUNAMI tools for assessment of system similarity using sensitivity andmore » uncertainty criteria are demonstrated. Uses of these criteria in trending analyses to assess computational biases, bias uncertainties, and gap analyses are also described. Additionally, an application of the data adjustment tool TSURFER is provided, including identification of specific details of sources of computational bias.« less
XENOBIOTIC METHODS DEVELOPMENT FOR HUMAN EXPOSURE ASSESSMENT RESEARCH
Biomarkers from blood, breath, urine, and other physiological matrices can provide useful information regarding exposures to environmental pollutants. Once developed and applied appropriately, specific and sensitive methods can often provide definitive data identifying the vario...
Xuan, Min; Zhou, Fengsheng; Ding, Yan; Zhu, Qiaoying; Dong, Ji; Zhou, Hao; Cheng, Jun; Jiang, Xiao; Wu, Pengxi
2018-04-01
To review the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) used to detect residual or recurrent liver tumors after radiofrequency ablation (RFA). This technique uses contrast-enhanced computer tomography or/and contrast-enhanced magnetic resonance imaging as the gold standard of investigation. MEDLINE, EMBASE, and COCHRANE were systematically searched for all potentially eligible studies comparing CEUS with the reference standard that follows RFA. Risk of bias and applicability concerns were addressed by adopting the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Pooled point estimates for sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratios (DOR) with 95% CI were computed before plotting the sROC (summary receiver operating characteristic) curve. Meta-regression and subgroup analysis were used to identify the source of the heterogeneity that was detected. Publication bias was evaluated using Deeks' funnel plot asymmetry test. Ten eligible studies on 1162 lesions that occurred between 2001 and 2016 were included in the final analysis. The quality of the included studies assessed by the QUADAS-2 tool was considered reasonable. The pooled sensitivity and specificity of CEUS in detecting residual or recurrent liver tumors had the following values: 0.90 (95% CI 0.85-0.94) and 1.00 (95% CI 0.99-1.00), respectively. Overall DOR was 420.10 (95% CI 142.30-1240.20). The sources of heterogeneity could not be precisely identified by meta-regression or subgroup analysis. No evidence of publication bias was found. This study confirmed that CEUS exhibits high sensitivity and specificity in assessing therapeutic responses to RFA for liver tumors.
Makdissi, Michael; Davis, Gavin
2016-10-01
The objective of this study was to determine the reliability and validity of identifying clinical signs of concussion using video analysis in Australian football. Prospective cohort study. All impacts and collisions potentially resulting in a concussion were identified during 2012 and 2013 Australian Football League seasons. Consensus definitions were developed for clinical signs associated with concussion. For intra- and inter-rater reliability analysis, two experienced clinicians independently assessed 102 randomly selected videos on two occasions. Sensitivity, specificity, positive and negative predictive values were calculated based on the diagnosis provided by team medical staff. 212 incidents resulting in possible concussion were identified in 414 Australian Football League games. The intra-rater reliability of the video-based identification of signs associated with concussion was good to excellent. Inter-rater reliability was good to excellent for impact seizure, slow to get up, motor incoordination, ragdoll appearance (2 of 4 analyses), clutching at head and facial injury. Inter-rater reliability for loss of responsiveness and blank and vacant look was only fair and did not reach statistical significance. The feature with the highest sensitivity was slow to get up (87%), but this sign had a low specificity (19%). Other video signs had a high specificity but low sensitivity. Blank and vacant look (100%) and motor incoordination (81%) had the highest positive predictive value. Video analysis may be a useful adjunct to the side-line assessment of a possible concussion. Video analysis however should not replace the need for a thorough multimodal clinical assessment. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Schaeffeler, Christoph; Waldt, Simone; Bauer, Jan S; Kirchhoff, Chlodwig; Haller, Bernhard; Schröder, Michael; Rummeny, Ernst J; Imhoff, Andreas B; Woertler, Klaus
2014-06-01
To evaluate diagnostic signs and measurements in the assessment of capsular redundancy in atraumatic multidirectional instability (MDI) of the shoulder on MR arthrography (MR-A) including abduction/external rotation (ABER) images. Twenty-one MR-A including ABER position of 20 patients with clinically diagnosed MDI and 17 patients without instability were assessed by three radiologists. On ABER images, presence of a layer of contrast between the humeral head (HH) and the anteroinferior glenohumeral ligament (AIGHL) (crescent sign) and a triangular-shaped space between the HH, AIGHL and glenoid (triangle sign) were evaluated; centring of the HH was measured. Anterosuperior herniation of the rotator interval (RI) capsule and glenoid version were determined on standard imaging planes. The crescent sign had a sensitivity of 57 %/62 %/48 % (observers 1/2/3) and specificity of 100 %/100 %/94 % in the diagnosis of MDI. The triangle sign had a sensitivity of 48 %/57 %/48 % and specificity of 94 %/94 %/100 %. The combination of both signs had a sensitivity of 86 %/90 %/81 % and specificity of 94 %/94 %/94 %. A positive triangle sign was significantly associated with decentring of the HH. Measurements of RI herniation, RI width and glenoid were not significantly different between both groups. Combined assessment of redundancy signs on ABER position MR-A allows for accurate differentiation between patients with atraumatic MDI and patients with clinically stable shoulders; measurements on standard imaging planes appear inappropriate. MR arthrography has the possibility to accurately identify patients with atraumatic MDI. Imaging of the shoulder in abduction and external rotation provides additive information. Capsular enlargement of the shoulder can be diagnosed on MR arthrography.
Ramsingh, Davinder; Frank, Ethan; Haughton, Robert; Schilling, John; Gimenez, Kimberly M; Banh, Esther; Rinehart, Joseph; Cannesson, Maxime
2016-05-01
Unrecognized malposition of the endotracheal tube (ETT) can lead to severe complications in patients under general anesthesia. The focus of this double-blinded randomized study was to assess the accuracy of point-of-care ultrasound in verifying the correct position of the ETT and to compare it with the accuracy of auscultation. Forty-two adult patients requiring general anesthesia with ETT were consented. Patients were randomized to right main bronchus, left main bronchus, or tracheal intubation. After randomization, the ETT was placed via fiber-optic visualization. Next, the location of the ETT was assessed using auscultation by a separate blinded anesthesiologist, followed by an ultrasound performed by a third blinded anesthesiologist. Ultrasound examination included assessment of tracheal dilation via cuff inflation with air and evaluation of pleural lung sliding. Statistical analysis included sensitivity, specificity, positive predictive value, negative predictive value, and interobserver agreement for the ultrasound examination (95% CI). In differentiating tracheal versus bronchial intubations, auscultation showed a sensitivity of 66% (0.39 to 0.87) and a specificity of 59% (0.39 to 0.77), whereas ultrasound showed a sensitivity of 93% (0.66 to 0.99) and specificity of 96% (0.79 to 1). Identification of tracheal versus bronchial intubation was 62% (26 of 42) in the auscultation group and 95% (40 of 42) in the ultrasound group (P = 0.0005) (CI for difference, 0.15 to 0.52), and the McNemar comparison showed statistically significant improvement with ultrasound (P < 0.0001). Interobserver agreement of ultrasound findings was 100%. Assessment of trachea and pleura via point-of-care ultrasound is superior to auscultation in determining the location of ETT.
2014-01-01
Background Estimation of the quantity of colostral IgG or serum IgG absorbed following ingestion of colostrum by calves is essential for monitoring the effectiveness of colostrum feeding practices on dairy farms. Milk total solids concentrations determination is a critical part of quality assessment of nonsaleable whole milk prior to feeding to calves. To date, on-farm methods to assess colostral IgG, serum IgG or milk total solids concentrations have been performed separately with various instruments. The objective of this study was to evaluate the diagnostic performance of a single electronic, hand-held refractometer for assessing colostral and serum IgG concentrations and milk total solids in dairy cattle. Colostral IgG, serum IgG and milk total solids concentrations were determined by the refractometer. Corresponding analysis of colostral and serum IgG concentrations were determined by radial immunodiffusion (RID) while milk total solids were determined by spectrophotometry. Sensitivity and specificity of the refractometer for colostrum and serum samples were calculated as determined by RID. Sensitivity and specificity of the refractometer for milk samples was calculated as determined by spectrophotometry. Results The sensitivity of the refractometer was 1 for colostral IgG, serum IgG and milk total solids determinations. Specificity of the refractometer was 0.66, 0.24 and 0 for colostral IgG, serum IgG and milk total solids determinations, respectively. The refractometer underestimated colostral IgG, serum IgG and milk total solids concentrations compared to the concentrations determined by RID or spectrophotometry. Conclusions The refractometer was an acceptable, rapid, convenient on-farm method for determining colostral IgG and milk total solids. The refractometer was not an acceptable method for determination of serum IgG concentrations as it severely underestimated the serum IgG concentrations. PMID:25125217
Muñoz Díaz, Belén; Molina-Recio, Guillermo; Romero-Saldaña, Manuel; Redondo Sánchez, Juana; Aguado Taberné, Cristina; Arias Blanco, Carmen; Molina-Luque, Rafael; Martínez De La Iglesia, Jorge
2018-06-05
To validate the Mini Nutritional Assessment (MNA) in a Spanish population over 65 years of age with varying degrees of independence. This cross-sectional validation study used the Chang nutritional assessment method as a reference test. 248 subjects (75.4% female), with a mean age of 83, completed the study. They were classified into three groups: (i) autonomous patients who were able to take part in activities outside their home; (ii) patients who require help with daily self-care; (iii) patients living in a residential health care facility. . Three health centres and three residential care homes situated in Cordoba (Spain). The kappa values for intra-observer and inter-observer agreement were 0.870 and 0.784, respectively. The intra-class correlation coefficient intra-observer was 0.874 and the inter-observer was 0.789. The sensitivity and specificity readings for the diagnostic accuracy of MNA were 63.2% and 72.9% in the total sample, respectively. The area under the curve was 0.726. For patients in the Group A, B and C, the sensitivity was 89.3%, 60.7% and 18.8%, and the specificity was 23.3%, 56.8% and 94.1%, respectively. The results for the reliability of the survey were excellent, and its internal consistency was acceptable. The diagnostic accuracy, as measured by the sensitivity and specificity readings, was lower than that obtained with the original survey. It can therefore be considered more suitable for a population with limited autonomy, and less appropriate for independent patients. The results may not be relevant to patients outside of the Cordova region in Spain.
Memory and Executive Screening for the Detection of Cognitive Impairment in Obstructive Sleep Apnea.
Mu, Li; Peng, Liping; Zhang, Zhengjiao; Jie, Jing; Jia, Siqi; Yuan, Haibo
2017-10-01
Obstructive sleep apnea (OSA) is commonly associated with cognitive dysfunction, which is more apparent in severe OSA and impairs quality of life. However, the clinical screening methods for these impairments in OSA are still limited. In this study, we evaluated the feasibility of using the Memory and Executive Screening (MES) for assessing cognitive performance in OSA. Twenty-four patients with nonsevere OSA and 36 patients with severe OSA participated in this study. All participants underwent comprehensive, laboratory-based polysomnography and completed assessments of cognitive function, which included both the MES and the Beijing version of the Montreal Cognitive Assessment (MoCA-BJ). Both the total MES scores and 5 recall scores of the MES (MES-5R) were significantly lower in the severe OSA group than those in the nonsevere OSA group. The patients with severe OSA performed worse on the memory subtests of the MES-5R, especially on immediate recall. The sensitivity and specificity of the MES for identifying cognitive impairment in patients with OSA were 63.89% and 66.67%, respectively, for a cutoff value of <92 out of 100 points. An optimal cutoff between nonsevere and severe OSA was also set at 45 points (MES-5R) and at 0.94 points (MES ratio). Compared with the MES, the MoCA-BJ had similar sensitivity (61.11%) and specificity (66.67%). The MES is an acceptable tool for detecting cognitive dysfunction in patients with OSA. The sensitivity and specificity of the MES were similar to those of the MoCA-BJ. The MES-5R and total MES scores can assess the presence and severity of cognitive impairment in patients with severe OSA. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Quek, Kia Fatt; Chua, Chong Beng; Razack, Azad Hassan; Low, Wah Yun; Loh, Chit Sin
2005-01-01
The purpose of the present study was to validate the Mandarin version of the International Prostate Symptom Score (Mand-IPSS) in a Malaysian population. The validity and reliability were studied in patients with lower urinary tract symptoms (LUTS; benign prostatic hyperplasia [BPH] group) and without LUTS (control group). Test-retest methodology was used to assess the reliability while Cronbach alpha was used to assess the internal consistency. Sensitivity to change was used to express the effect size index in the preintervention versus post-intervention score in patients with LUTS who underwent transurethral resection of the prostate. For the control group and BPH group, the internal consistency was excellent and a high degree of internal consistency was observed for all seven items (Cronbach alpha = 0.86-0.98 and 0.90-0.98, respectively). Test-retest correlation coefficients for all items were highly significant. Intraclass correlation coefficient (ICC) was high for the control (ICC = 0.93-0.99) and BPH group (ICC = 0.91-0.99). The sensitivity and specificity showed a high degree of sensitivity and specificity to the effects of treatment. A high degree of significance between baseline and post-treatment scores was observed across all seven items in the BPH group but not in the control group. The Mand-IPSS is a suitable, reliable, valid and sensitive instrument to measure clinical change in the Malaysian population.
Analyzing reflective narratives to assess the ethical reasoning of pediatric residents.
Moon, Margaret; Taylor, Holly A; McDonald, Erin L; Hughes, Mark T; Beach, Mary Catherine; Carrese, Joseph A
2013-01-01
A limiting factor in ethics education in medical training has been difficulty in assessing competence in ethics. This study was conducted to test the concept that content analysis of pediatric residents' personal reflections about ethics experiences can identify changes in ethical sensitivity and reasoning over time. Analysis of written narratives focused on two of our ethics curriculum's goals: 1) To raise sensitivity to ethical issues in everyday clinical practice and 2) to enhance critical reflection on personal and professional values as they affect patient care. Content analysis of written reflections was guided by a tool developed to identify and assess the level of ethical reasoning in eight domains determined to be important aspects of ethical competence. Based on the assessment of narratives written at two times (12 to 16 months/apart) during their training, residents showed significant progress in two specific domains: use of professional values, and use of personal values. Residents did not show decline in ethical reasoning in any domain. This study demonstrates that content analysis of personal narratives may provide a useful method for assessment of developing ethical sensitivity and reasoning.
Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio.
Spagnoli, Vincent; Picard, Fabien; Tadros, Victor-Xavier; Cournoyer, Daniel; Doucet, Serge; Tanguay, Jean François; Gosselin, Gilbert; de Guise, Pierre; Gallo, Richard
2018-04-01
Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR). Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR. A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76-1) vs. 0.89 (95% CI: 0.79-0.99), P=0.89]. Youden's index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98-1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%). When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility.
Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio
Spagnoli, Vincent; Picard, Fabien; Tadros, Victor-Xavier; Cournoyer, Daniel; Doucet, Serge; Tanguay, Jean François; Gosselin, Gilbert; de Guise, Pierre
2018-01-01
Background Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR). Methods Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR. Results A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76–1) vs. 0.89 (95% CI: 0.79–0.99), P=0.89]. Youden’s index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98–1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%). Conclusions When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility. PMID:29850406
Kurien, Regi; Chrisolyte, Shipra; Rupa, V
2009-09-01
To assess eustachian tubal function (ETF) preoperatively in patients with chronic suppurative otitis media (CSOM) with central perforation by performing the inflation-deflation test. To correlate the results of the inflation-deflation test with the finding of aditus patency or block in patients with CSOM STUDY DESIGN: Prospective, cohort Tertiary care hospital Eighty adult patients with chronic suppurative otitis media and central perforation were recruited into the study. There were 45 males and 35 females. All patients underwent preoperative inflation-deflation test followed by cortical mastoidectomy and tympanoplasty. The patency of the aditus was assessed intraoperatively. Equalization of pressure on inflation-deflation test and intraoperative assessment of aditus patency Of a total of 80 patients, 49 patients were found to have discharging ears and 31 had dry ears at the time of surgery. In dry ears the inflation-deflation test had a sensitivity of 93% in predicting aditus patency although the specificity was lower at 67%. In discharging ears the sensitivity in predicting aditus patency was 72% and the specificity was 67%. The eustachian tube inflation-deflation test is a sensitive test for predicting aditus patency in patients with dry ears but less so in patients with discharging ears. Hence, it could be used in the former to avoid unnecessary exploration of the mastoid.
Classifying post-stroke fatigue: Optimal cut-off on the Fatigue Assessment Scale.
Cumming, Toby B; Mead, Gillian
2017-12-01
Post-stroke fatigue is common and has debilitating effects on independence and quality of life. The Fatigue Assessment Scale (FAS) is a valid screening tool for fatigue after stroke, but there is no established cut-off. We sought to identify the optimal cut-off for classifying post-stroke fatigue on the FAS. In retrospective analysis of two independent datasets (the '2015' and '2007' studies), we evaluated the predictive validity of FAS score against a case definition of fatigue (the criterion standard). Area under the curve (AUC) and sensitivity and specificity at the optimal cut-off were established in the larger 2015 dataset (n=126), and then independently validated in the 2007 dataset (n=52). In the 2015 dataset, AUC was 0.78 (95% CI 0.70-0.86), with the optimal ≥24 cut-off giving a sensitivity of 0.82 and specificity of 0.66. The 2007 dataset had an AUC of 0.83 (95% CI 0.71-0.94), and applying the ≥24 cut-off gave a sensitivity of 0.84 and specificity of 0.67. Post-hoc analysis of the 2015 dataset revealed that using only the 3 most predictive FAS items together ('FAS-3') also yielded good validity: AUC 0.81 (95% CI 0.73-0.89), with sensitivity of 0.83 and specificity of 0.75 at the optimal ≥8 cut-off. We propose ≥24 as a cut-off for classifying post-stroke fatigue on the FAS. While further validation work is needed, this is a positive step towards a coherent approach to reporting fatigue prevalence using the FAS. Copyright © 2017 Elsevier Inc. All rights reserved.
Sung, Ki Hyuk; Choi, Young; Cho, Gyeong Hee; Chung, Chin Youb; Park, Moon Seok; Lee, Kyoung Min
2018-02-05
This study evaluated the correlation between central and peripheral bone mineral density (BMD) of the ankle joint, using dual-energy X-ray absorptiometry (DXA). We also investigated whether peripheral ankle BMD could be used to identify individuals who were diagnosed with osteoporosis, using central DXA. We recruited 134 volunteers aged 20-90 years who agreed to participate in this study. Central BMD of the lumbar spine and left femur, and peripheral BMD of the medial malleolus, distal tibia, lateral malleolus, and talus were measured with DXA. Among the peripheral sites of the ankle, the highest and lowest BMD were observed in the talus and lateral malleolus, respectively. All peripheral DXA measurements of the ankle joint were significantly correlated with central DXA measurements. There was a good correlation (r: 0.656-0.725) between peripheral and central BMD for the older age group (> 50 years), but fair-to-good correlation (r: 0.263-0.654) for the younger age group (< 50 years). The cut-off values for peripheral BMD of the ankle joint between osteoporosis and non-osteoporosis were 0.548 g/cm 2 (sensitivity, 89.0%; specificity, 69.0%) for the medial malleolus, 0.626 g/cm 2 (sensitivity, 83.3%; specificity, 82.8%) for the distal tibia, 0.47 g/cm 2 (sensitivity, 100.0%; specificity, 65.5%) for the lateral malleolus, and 0.973 g/cm 2 (sensitivity, 72.2%; specificity, 83.6%) for the talus (p < 0.001). This study showed good correlation between peripheral BMD around ankle joint and central BMD for older age group. Further study is required to use the ankle DXA as a valid clinical tool for the diagnosis of osteoporosis and fracture risk assessment.
Adriaens, E; Willoughby, J A; Meyer, B R; Blakeman, L C; Alépée, N; Fochtman, P; Guest, R; Kandarova, H; Verstraelen, S; Van Rompay, A R
2018-06-01
Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium was developed to assess the reliability of eight in vitro test methods and establish an optimal tiered-testing strategy. One assay selected was the Short Time Exposure (STE) assay. This assay measures the viability of SIRC rabbit corneal cells after 5min exposure to 5% and 0.05% solutions of test material, and is capable of categorizing of Category 1 and No Category chemicals. The accuracy of the STE test method to identify Cat 1 chemicals was 61.3% with 23.7% sensitivity and 95.2% specificity. If non-soluble chemicals and unqualified results were excluded, the performance to identify Cat 1 chemicals remained similar (accuracy 62.2% with 22.7% sensitivity and 100% specificity). The accuracy of the STE test method to identify No Cat chemicals was 72.5% with 66.2% sensitivity and 100% specificity. Excluding highly volatile chemicals, non-surfactant solids and non-qualified results resulted in an important improvement of the performance of the STE test method (accuracy 96.2% with 81.8% sensitivity and 100% specificity). Furthermore, it seems that solids are more difficult to test in the STE, 71.4% of the solids resulted in unqualified results (solubility issues and/or high variation between independent runs) whereas for liquids 13.2% of the results were not qualified, supporting the restriction of the test method regarding the testing of solids. Copyright © 2017. Published by Elsevier Ltd.
[Internal validity and diagnostic utility of the Eating Disorder Inventory in Mexican women].
García-García, Eduardo; Vázquez-Velázquez, Verónica; López-Alvarenga, Juan Carlos; Arcila-Martínez, Denise
2003-01-01
To assess the diagnostic utility and internal validity of the Eating Disorder Inventory (EDI-2) in Mexican women. An observational, cross-sectional study was conducted between October 2000 and January 2001. The sample population consisted of two groups of women: patients diagnosed with anorexia nervosa or bulimia, but no other psychiatric pathology, seen by psychiatrists at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán (National Institute of Medical Sciences and Nutrition Salvador Zubirán), and a randomly selected sample of women from a school in Mexico City. A structured interview was conducted using SCID/DSM-IV as the gold standard. Finally the EDI-2 was administered. Statistical analysis was performed using Student's t test for independent samples, Cronbach's alpha test, and calculation of sensitivity, specificity, and positive and negative predictive values. No significant differences were found for weight, height, and body mass index. Women with no eating disorders were younger than those with eating disorders (16.7 +/- 2.8 vs. 19.9 +/- 4.3, p = 0.004). The EDI-2 total score was clearly different between the groups (53.8 +/- 32.4 vs. 146.3 +/- 45.6 respectively, p < 0.001). All Cronbach's alpha coefficients for all subscales were over 0.85. For the total score, a sensitive cutoff point of 80 (sensitivity 90.9, 95% confidence interval [CI] 69.4 to 98.4; specificity 80, 95% CI 58.7 to 92.4) and a specific cutoff point of 105 (sensitivity 81.8, 95% CI 59 to 94; specificity 89.3, 95% CI 70.6 to 97.2) are recommended. The EDI-2 has a high internal validity and should be a useful tool to assess eating disorders.
Pivetta, Emanuele; Goffi, Alberto; Lupia, Enrico; Tizzani, Maria; Porrino, Giulio; Ferreri, Enrico; Volpicelli, Giovanni; Balzaretti, Paolo; Banderali, Alessandra; Iacobucci, Antonello; Locatelli, Stefania; Casoli, Giovanna; Stone, Michael B; Maule, Milena M; Baldi, Ileana; Merletti, Franco; Cibinel, Gian Alfonso; Baron, Paolo; Battista, Stefania; Buonafede, Giuseppina; Busso, Valeria; Conterno, Andrea; Del Rizzo, Paola; Ferrera, Patrizia; Pecetto, Paolo Fascio; Moiraghi, Corrado; Morello, Fulvio; Steri, Fabio; Ciccone, Giovannino; Calasso, Cosimo; Caserta, Mimma A; Civita, Marina; Condo', Carmen; D'Alessandro, Vittorio; Del Colle, Sara; Ferrero, Stefania; Griot, Giulietta; Laurita, Emanuela; Lazzero, Alberto; Lo Curto, Francesca; Michelazzo, Marianna; Nicosia, Vincenza; Palmari, Nicola; Ricchiardi, Alberto; Rolfo, Andrea; Rostagno, Roberto; Bar, Fabrizio; Boero, Enrico; Frascisco, Mauro; Micossi, Ilaria; Mussa, Alessandro; Stefanone, Valerio; Agricola, Renzo; Cordero, Gabriele; Corradi, Federica; Runzo, Cristina; Soragna, Aldo; Sciullo, Daniela; Vercillo, Domenico; Allione, Attilio; Artana, Nicoletta; Corsini, Fabrizio; Dutto, Luca; Lauria, Giuseppe; Morgillo, Teresa; Tartaglino, Bruno; Bergandi, Daniela; Cassetta, Ilaria; Masera, Clotilde; Garrone, Mario; Ghiselli, Gianluca; Ausiello, Livia; Barutta, Letizia; Bernardi, Emanuele; Bono, Alessia; Forno, Daniela; Lamorte, Alessandro; Lison, Davide; Lorenzati, Bartolomeo; Maggio, Elena; Masi, Ilaria; Maggiorotto, Matteo; Novelli, Giulia; Panero, Francesco; Perotto, Massimo; Ravazzoli, Marco; Saglio, Elisa; Soardo, Flavia; Tizzani, Alessandra; Tizzani, Pietro; Tullio, Mattia; Ulla, Marco; Romagnoli, Elisa
2015-07-01
Lung ultrasonography (LUS) has emerged as a noninvasive tool for the differential diagnosis of pulmonary diseases. However, its use for the diagnosis of acute decompensated heart failure (ADHF) still raises some concerns. We tested the hypothesis that an integrated approach implementing LUS with clinical assessment would have higher diagnostic accuracy than a standard workup in differentiating ADHF from noncardiogenic dyspnea in the ED. We conducted a multicenter, prospective cohort study in seven Italian EDs. For patients presenting with acute dyspnea, the emergency physician was asked to categorize the diagnosis as ADHF or noncardiogenic dyspnea after (1) the initial clinical assessment and (2) after performing LUS ("LUS-implemented" diagnosis). All patients also underwent chest radiography. After discharge, the cause of each patient's dyspnea was determined by independent review of the entire medical record. The diagnostic accuracy of the different approaches was then compared. The study enrolled 1,005 patients. The LUS-implemented approach had a significantly higher accuracy (sensitivity, 97% [95% CI, 95%-98.3%]; specificity, 97.4% [95% CI, 95.7%-98.6%]) in differentiating ADHF from noncardiac causes of acute dyspnea than the initial clinical workup (sensitivity, 85.3% [95% CI, 81.8%-88.4%]; specificity, 90% [95% CI, 87.2%-92.4%]), chest radiography alone (sensitivity, 69.5% [95% CI, 65.1%-73.7%]; specificity, 82.1% [95% CI, 78.6%-85.2%]), and natriuretic peptides (sensitivity, 85% [95% CI, 80.3%-89%]; specificity, 61.7% [95% CI, 54.6%-68.3%]; n = 486). Net reclassification index of the LUS-implemented approach compared with standard workup was 19.1%. The implementation of LUS with the clinical evaluation may improve accuracy of ADHF diagnosis in patients presenting to the ED. Clinicaltrials.gov; No.: NCT01287429; URL: www.clinicaltrials.gov.
Noble, Fergus; Curtis, Nathan; Harris, Scott; Kelly, Jamie J; Bailey, Ian S; Byrne, James P; Underwood, Timothy J
2012-06-01
Oesophagectomy is associated with significant morbidity and mortality. A simple score to define a patient's risk of developing major complications would be beneficial. Patients who underwent upper gastrointestinal resections with an oesophageal anastomosis between 2005 and 2010 were reviewed and formed the development dataset with resections performed in 2011 forming a prospective validation dataset. The association between post-operative C-reactive protein (CRP), white cell count (WCC) and albumin levels with anastomotic leak (AL) or major complication including death using the Clavien-Dindo (CD) classification were analysed by receiver operating characteristic curves. After multivariate analysis, from the development dataset, these factors were combined to create a novel score which was subsequently tested on the validation dataset. Two hundred fifty-eight patients were assessed to develop the score. Sixty-three patients (25%) developed a major complication, and there were seven (2.7%) in-patient deaths. Twenty-six (10%) patients were diagnosed with AL at median post-operative day 7 (range: 5-15). CRP (p = 0.002), WCC (p < 0.0001) and albumin (p = 0.001) were predictors of AL. Combining these markers improved prediction of AL (NUn score > 10: sensitivity 95%, specificity 49%, diagnostic accuracy 0.801 (95% confidence interval: 0.692-0.909, p < 0.0001)). The validation dataset confirmed these findings (NUn score > 10: sensitivity 100%, specificity 57%, diagnostic accuracy 0.879 (95% CI 0.763-0.994, p = 0.014)) and a major complication or death (NUn > 10: sensitivity 89%, specificity 63%, diagnostic accuracy 0.856 (95% CI 0.709-1, p = 0.001)). Blood-borne markers of the systemic inflammatory response are predictors of AL and major complications after oesophageal resection. When combined they may categorise a patient's risk of developing a serious complication with higher sensitivity and specificity.
Pfluger, Thomas; Schmied, Christoph; Porn, Ute; Leinsinger, Gerda; Vollmar, Christian; Dresel, Stefan; Schmid, Irene; Hahn, Klaus
2003-10-01
The objectives of this study were to compare MRI and iodine-123 ((123)I) metaiodobenzylguanidine (MIBG) scintigraphy in the detection of neuroblastoma lesions in pediatric patients and to assess the additional value of combined imaging. Fifty MRI and 50 (123)I MIBG examinations (mean interval, 6.4 days) were analyzed retrospectively with regard to suspected or proven neuroblastoma lesions (n = 193) in 28 patients. MRI and MIBG scans were reviewed by two independent observers each. Separate and combined analyses of MRI and MIBG scintigraphy were compared with clinical and histologic findings. With regard to the diagnosis of neuroblastoma lesion, MIBG scintigraphy, MRI, and combined analysis showed a sensitivity of 69%, 86%, and 99% and a specificity of 85%, 77%, and 95%, respectively. On MRI, 15 false-positive findings were recorded: posttherapeutic reactive changes (n = 10), benign adrenal tumors (n = 3), and enlarged lymph nodes (n = 2). On MIBG scintigraphy, 10 false-positive findings occurred: ganglioneuromas (n = 2), benign liver tumors (n = 2), and physiologic uptake (n = 6). Thirteen neuroblastoma metastases and two residual masses under treatment with chemotherapy were judged to be false-negative findings on MRI. Two primary or residual neuroblastomas and one orbital metastasis were misinterpreted as Wilms' tumor, reactive changes after surgery, and rhabdomyosarcoma on MRI. Thirty-two bone metastases, six other neuroblastoma metastases, and one adrenal neuroblastoma showed no MIBG uptake. On combined imaging, one false-negative (bone metastasis) and three false-positive (two ganglioneuromas and one pheochromocytoma) findings remained. In the assessment of neuroblastoma lesions in pediatric patients, MRI showed a higher sensitivity and MIBG scintigraphy a higher specificity. However, integrated imaging showed an increase in both sensitivity and specificity.
Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying
2015-01-01
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758
Formichella, Luca; Romberg, Laura; Bolz, Christian; Vieth, Michael; Geppert, Michael; Göttner, Gereon; Nölting, Christina; Walter, Dirk; Schepp, Wolfgang; Schneider, Arne; Ulm, Kurt; Wolf, Petra; Busch, Dirk H; Soutschek, Erwin; Gerhard, Markus
2013-11-01
Helicobacter pylori colonizes half of the world's population, and infection can lead to ulcers, gastric cancer, and mucosa-associated lymphoid tissue (MALT) lymphoma. Serology is the only test applicable for large-scale, population-based screening, but current tests are hampered by a lack of sensitivity and/or specificity. Also, no serologic test allows the differentiation of type I and type II strains, which is important for predicting the clinical outcome. H. pylori virulence factors have been associated with disease, but direct assessment of virulence factors requires invasive methods to obtain gastric biopsy specimens. Our work aimed at the development of a highly sensitive and specific, noninvasive serologic test to detect immune responses to important H. pylori virulence factors. This line immunoassay system (recomLine) is based on recombinant proteins. For this assay, six highly immunogenic virulence factors (CagA, VacA, GroEL, gGT, HcpC, and UreA) were expressed in Escherichia coli, purified, and immobilized to nitrocellulose membranes to detect serological immune responses in patient's sera. For the validation of the line assay, a cohort of 500 patients was screened, of which 290 (58.0%) were H. pylori negative and 210 (42.0%) were positive by histology. The assay showed sensitivity and specificity of 97.6% and 96.2%, respectively, compared to histology. In direct comparison to lysate blotting and enzyme-linked immunosorbent assay (ELISA), the recomLine assay had increased discriminatory power. For the assessment of individual risk for gastrointestinal disease, the test must be validated in a larger and defined patient cohort. Taking the data together, the recomLine assay provides a valuable tool for the diagnosis of H. pylori infection.
Bjurström, M F; Álvarez, R; Nicol, A L; Olmstead, R; Amid, P K; Chen, D C
2017-04-01
Neurectomy of the inguinal nerves may be considered for selected refractory cases of chronic postherniorrhaphy inguinal pain (CPIP). There is to date a paucity of easily applicable clinical tools to identify neuropathic pain and examine the neurosensory effects of remedial surgery. The present quantitative sensory testing (QST) pilot study evaluates a sensory mapping technique. Longitudinal (preoperative, immediate postoperative, and late postoperative) dermatomal sensory mapping and a comprehensive QST protocol were conducted in CPIP patients with unilateral, predominantly neuropathic inguinodynia presenting for triple neurectomy (n = 13). QST was conducted in four areas on the affected, painful side and in one contralateral comparison site. QST variables were compared according to sensory mapping outcomes: (o)/normal sensation, (+)/pain, and (-)/numbness. Diagnostic ability of the sensory mapping outcomes to detect QST-assessed allodynia or hypoesthesia was estimated through calculation of specificity and sensitivity values. Preoperatively, patients exhibited mechanical hypoesthesia and allodynia and pressure allodynia and hyperalgesia in painful areas mapped (+) (p < .05); sensory mapping outcome (+) demonstrated high ability to detect mechanical allodynia [sensitivity 0.74 (95% CI 0.61-0.86), specificity 0.94 (0.84-1.00)] and pressure allodynia [sensitivity 0.96 (0.89-1.00), specificity 1.00 (1.00-1.00)], but not thermal allodynia. Postoperatively, mapped areas of numbness (-) were associated with mechanical and thermal hypoesthesia (p < .05); (-) showed high sensitivity and specificity to detect mechanical and cold hypoesthesia. Sensory mapping provides an accurate clinical neuropathic assessment with strong correlation to QST findings of preoperative mechanical and pressure allodynia, and postoperative mechanical and thermal hypoesthesia in CPIP patients undergoing neurectomy.
A method for identifying color vision deficiency malingering.
Pouw, Andrew; Karanjia, Rustum; Sadun, Alfredo
2017-03-01
To propose a new test to identify color vision deficiency malingering. An online survey was distributed to 130 truly color vision deficient participants and 160 participants willing to simulate color vision deficiency. The survey contained three sets of six color-adjusted versions of the standard Ishihara color plates each, as well as one set of six control plates. The plates that best discriminated both participant groups were selected for a "balanced" test emphasizing both sensitivity and specificity. A "specific" test that prioritized high specificity was also created by selecting from these plates. Statistical measures of the test (sensitivity, specificity, and Youden index) were assessed at each possible cut-off threshold, and a receiver operating characteristic (ROC) function with its area under the curve (AUC) charted. The redshift plate set was identified as having the highest difference of means between groups (-58%, CI: -64 to -52%), as well as the widest gap between group modes. Statistical measures of the "balanced" test show an optimal cut-off of at least two incorrectly identified plates to suggest malingering (Youden index: 0.773, sensitivity: 83.3%, specificity: 94.0%, AUC of ROC 0.918). The "specific" test was able to identify color vision deficiency simulators with a specificity of 100% when using a cut-off of at least two incorrectly identified plates (Youden index 0.599, sensitivity 59.9%, specificity 100%, AUC of ROC 0.881). Our proposed test for identifying color vision deficiency malingering demonstrates a high degree of reliability with AUCs of 0.918 and 0.881 for the "balanced" and "specific" tests, respectively. A cut-off threshold of at least two missed plates on the "specific" test was able to identify color vision deficiency simulators with 100% specificity.
Sensitivity and specificity of digital retinal imaging for screening diabetic retinopathy.
Lopez-Bastida, J; Cabrera-Lopez, F; Serrano-Aguilar, P
2007-04-01
To assess the effectiveness of a non-mydriatic digital camera (45 degrees -30 degrees photographs) compared with the reference method for screening diabetic retinopathy. Type 1 and 2 diabetic patients (n = 773; 1546 eyes) underwent screening for diabetic retinopathy in a prospective observational study. Hospital-based non-mydriatic digital retinal imaging by a consultant specialist in retinal diseases was compared with slit-lamp biomicroscopy and indirect ophthalmoscopy through dilated pupils, as a gold standard, previously performed in a community health centre by another consultant specialist in retinal diseases. The main outcome measures were sensitivity and specificity of screening methods and prevalence of diabetic retinopathy. The prevalence of any form of diabetic retinopathy was 42.4% (n = 328); the prevalence of sight-threatening including macular oedema and proliferative retinopathy was 9.6% (n = 74). Sensitivity of detection of any diabetic retinopathy by digital imaging was 92% (95% confidence interval 90, 94). Specificity of detection of any diabetic retinopathy was 96% (95, 98). The predictive value of the negative tests was 94% and of a positive test 95%. For sight-threatening retinopathy digital imaging had a sensitivity of 100%. A high sensitivity and specificity are essential for an effective screening programme. These results confirm digital retinal imaging with a non-mydriatic camera as an effective option in community-based screening programmes for diabetic retinopathy.
Labanca, Ludimila; Alves, Cláudia Regina Lindgren; Bragança, Lidia Lourenço Cunha; Dorim, Diego Dias Ramos; Alvim, Cristina Gonçalves; Lemos, Stela Maris Aguiar
2015-01-01
To establish cutoff points for the analysis of the Behavior Observation Form (BOF) of children in the ages of 2 to 23 months and evaluate the sensitivity and specificity by age group and domains (Emission, Reception, and Cognitive Aspects of Language). The sample consisted of 752 children who underwent BOF. Each child was classified as having appropriate language development for the age or having possible risk of language impairment. Performance Indicators (PI) were calculated in each domain as well as the overall PI in all domains. The values for sensitivity and specificity were also calculated. The cutoff points for possible risk of language impairment for each domain and each age group were obtained using the receiver operating characteristics curve. The results of the study revealed that one-third of the assessed children have a risk of language impairment in the first two years of life. The analysis of BOF showed high sensitivity (>90%) in all categories and in all age groups; however, the chance of false-positive results was higher than 20% in the majority of aspects evaluated. It was possible to establish the cutoff points for all categories and age groups with good correlation between sensitivity and specificity, except for the age group of 2 to 6 months. This study provides important contributions to the discussion on the evaluation of the language development of children younger than 2 years.
Jurate, Kondrackiene; Rimantas, Zalinkevicius; Jolanta, Sumskiene; Vladas, Gintautas; Limas, Kupcinskas
2017-01-01
Intrahepatic cholestasis of pregnancy (ICP) is linked with increased risk of fetal complications. An accurate diagnostic test is needed to diagnose this disorder on time. We aimed to assess sensitivity and specificity of laboratory tests used for diagnosis of intrahepatic cholestasis of pregnancy and determine more reliable cut-off values of transaminases. Sixty one symptomatic patients with ICP and 29 healthy pregnant women were included in the retrospective analysis. ICP patients had higher total bile acids (TBA) levels than healthy women (32 vs. 6; P < 0.0001) due to increase in cholic acid (CA) and chenodeoxycholic acid (CDCA). CA/CDCA ratio was significantly higher in ICP patients compared to healthy pregnant women (1.13 vs. 0.68; P < 0.00002). TBA, CA, CDCA and CA/CDCA ratio demonstrate the following sensitivity (94%, 96%, 89%, 71.9%) and specificity (63%, 63%, 59%, 79.3%, respectively) for ICP diagnosis. Lowering cut-off values for ALT (31 U/L) and AST (30 U/L) resulted only in minimal increase of sensitivity to 92.2% vs. 90.1% for ALT and to 92.2%, vs. 90.6% for AST. The present study did not reveal any single specific and sensitive marker for reliable diagnosis of ICP. Establishment of lower cut-off values for transaminases activity might only minimally increase the accuracy of diagnosing ICP.
The diagnostic value of narrow-band imaging for early and invasive lung cancer: a meta-analysis.
Zhu, Juanjuan; Li, Wei; Zhou, Jihong; Chen, Yuqing; Zhao, Chenling; Zhang, Ting; Peng, Wenjia; Wang, Xiaojing
2017-07-01
This study aimed to compare the ability of narrow-band imaging to detect early and invasive lung cancer with that of conventional pathological analysis and white-light bronchoscopy. We searched the PubMed, EMBASE, Sinomed, and China National Knowledge Infrastructure databases for relevant studies. Meta-disc software was used to perform data analysis, meta-regression analysis, sensitivity analysis, and heterogeneity testing, and STATA software was used to determine if publication bias was present, as well as to calculate the relative risks for the sensitivity and specificity of narrow-band imaging vs those of white-light bronchoscopy for the detection of early and invasive lung cancer. A random-effects model was used to assess the diagnostic efficacy of the above modalities in cases in which a high degree of between-study heterogeneity was noted with respect to their diagnostic efficacies. The database search identified six studies including 578 patients. The pooled sensitivity and specificity of narrow-band imaging were 86% (95% confidence interval: 83-88%) and 81% (95% confidence interval: 77-84%), respectively, and the pooled sensitivity and specificity of white-light bronchoscopy were 70% (95% confidence interval: 66-74%) and 66% (95% confidence interval: 62-70%), respectively. The pooled relative risks for the sensitivity and specificity of narrow-band imaging vs the sensitivity and specificity of white-light bronchoscopy for the detection of early and invasive lung cancer were 1.33 (95% confidence interval: 1.07-1.67) and 1.09 (95% confidence interval: 0.84-1.42), respectively, and sensitivity analysis showed that narrow-band imaging exhibited good diagnostic efficacy with respect to detecting early and invasive lung cancer and that the results of the study were stable. Narrow-band imaging was superior to white light bronchoscopy with respect to detecting early and invasive lung cancer; however, the specificities of the two modalities did not differ significantly.
2013-01-01
Background The rapid diagnostic test (RDT) has been adopted in contemporary malaria control and management programmes around the world as it represents a fast and apt alternative for malaria diagnosis in a resource-limited setting. This study assessed the performance of a HRP-2/pLDH based RDT (Parascreen® Pan/Pf) in a laboratory setting utilizing clinical samples obtained from the field. Methods Whole blood samples were obtained from febrile patients referred for malaria diagnosis by clinicians from two different Upazila Health Complexes (UHCs) located near the Bangladesh-India and Bangladesh-Myanmar border where malaria is endemic. RDT was performed on archived samples and sensitivity and specificity evaluated with expert microscopy (EM) and quantitative PCR (qPCR). Results A total of 327 clinical samples were made available for the study, of which 153 were Plasmodium falciparum-positive and 54 were Plasmodium vivax-positive. In comparison with EM, for P. falciparum malaria, the RDT had sensitivity: 96.0% (95% CI, 91.2-98.3) and specificity: 98.2% (95% CI, 94.6-99.5) and for P. vivax, sensitivity: 90.7% (95% CI, 78.9-96.5) and specificity: 98.9% (95% CI, 96.5-99.7). Comparison with qPCR showed, for P. falciparum malaria, sensitivity: 95.4% (95% CI, 90.5-98.0) and specificity: 98.8% (95% CI, 95.4-99.7) and for P. vivax malaria, sensitivity: 89.0% (95% CI,77.0-95.4) and specificity: 98.8% (95% CI, 96.5-99.7). Sensitivity varied according to different parasitaemia for falciparum and vivax malaria diagnosis. Conclusion Parascreen® Pan/Pf Rapid test for malaria showed acceptable sensitivity and specificity in border belt endemic areas of Bangladesh when compared with EM and qPCR. PMID:24172045
Physical examination for lumbar radiculopathy due to disc herniation in patients with low-back pain.
van der Windt, Daniëlle Awm; Simons, Emmanuel; Riphagen, Ingrid I; Ammendolia, Carlo; Verhagen, Arianne P; Laslett, Mark; Devillé, Walter; Deyo, Rick A; Bouter, Lex M; de Vet, Henrica Cw; Aertgeerts, Bert
2010-02-17
Low-back pain with leg pain (sciatica) may be caused by a herniated intervertebral disc exerting pressure on the nerve root. Most patients will respond to conservative treatment, but in carefully selected patients, surgical discectomy may provide faster relief of symptoms. Primary care clinicians use patient history and physical examination to evaluate the likelihood of disc herniation and select patients for further imaging and possible surgery. (1) To assess the performance of tests performed during physical examination (alone or in combination) to identify radiculopathy due to lower lumbar disc herniation in patients with low-back pain and sciatica;(2) To assess the influence of sources of heterogeneity on diagnostic performance. We searched electronic databases for primary studies: PubMed (includes MEDLINE), EMBASE, and CINAHL, and (systematic) reviews: PubMed and Medion (all from earliest until 30 April 2008), and checked references of retrieved articles. We considered studies if they compared the results of tests performed during physical examination on patients with back pain with those of diagnostic imaging (MRI, CT, myelography) or findings at surgery. Two review authors assessed the quality of each publication with the QUADAS tool, and extracted details on patient and study design characteristics, index tests and reference standard, and the diagnostic two-by-two table. We presented information on sensitivities and specificities with 95% confidence intervals (95% CI) for all aspects of physical examination. Pooled estimates of sensitivity and specificity were computed for subsets of studies showing sufficient clinical and statistical homogeneity. We included 16 cohort studies (median N = 126, range 71 to 2504) and three case control studies (38 to100 cases). Only one study was carried out in a primary care population. When used in isolation, diagnostic performance of most physical tests (scoliosis, paresis or muscle weakness, muscle wasting, impaired reflexes, sensory deficits) was poor. Some tests (forward flexion, hyper-extension test, and slump test) performed slightly better, but the number of studies was small. In the one primary care study, most tests showed higher specificity and lower sensitivity compared to other settings.Most studies assessed the Straight Leg Raising (SLR) test. In surgical populations, characterized by a high prevalence of disc herniation (58% to 98%), the SLR showed high sensitivity (pooled estimate 0.92, 95% CI: 0.87 to 0.95) with widely varying specificity (0.10 to 1.00, pooled estimate 0.28, 95% CI: 0.18 to 0.40). Results of studies using imaging showed more heterogeneity and poorer sensitivity. The crossed SLR showed high specificity (pooled estimate 0.90, 95% CI: 0.85 to 0.94) with consistently low sensitivity (pooled estimate 0.28, 95% CI: 0.22 to 0.35).Combining positive test results increased the specificity of physical tests, but few studies presented data on test combinations. When used in isolation, current evidence indicates poor diagnostic performance of most physical tests used to identify lumbar disc herniation. However, most findings arise from surgical populations and may not apply to primary care or non-selected populations. Better performance may be obtained when tests are combined.
Korosoglou, Grigorios; Dubart, Alain-Eric; DaSilva, K Gaspar C; Labadze, Nino; Hardt, Stefan; Hansen, Alexander; Bekeredjian, Raffi; Zugck, Christian; Zehelein, Joerg; Katus, Hugo A; Kuecherer, Helmut
2006-01-01
Little is known about the incremental value of real-time myocardial contrast echocardiography (MCE) as an adjunct to pharmacologic stress testing. This study was performed to evaluate the diagnostic value of MCE to detect abnormal myocardial perfusion by technetium Tc 99m sestamibi-single photon emission computed tomography (SPECT) and anatomically significant coronary artery disease (CAD) by angiography. Myocardial contrast echocardiography was performed at rest and during vasodilator stress in consecutive patients (N = 120) undergoing SPECT imaging for known or suspected CAD. Myocardial opacification, wall motion, and tracer uptake were visually analyzed in 12 myocardial segments by 2 pairs of blinded observers. Concordance between the 2 methods was assessed using the kappa statistic. Of 1356 segments, 1025 (76%) were interpretable by MCE, wall motion, and SPECT. Sensitivity of wall motion was 75%, specificity 83%, and accuracy 81% for detecting abnormal myocardial perfusion by SPECT (kappa = 0.53). Myocardial contrast echocardiography and wall motion together yielded significantly higher sensitivity (85% vs 74%, P < .05), specificity of 83%, and accuracy of 85% (kappa = 0.64) for the detection of abnormal myocardial perfusion. In 89 patients who underwent coronary angiography, MCE and wall motion together yielded higher sensitivity (83% vs 64%, P < .05) and accuracy (77% vs 68%, P < .05) but similar specificity (72%) compared with SPECT for the detection of high-grade, stenotic (> or = 75%) coronary lesions. Assessment of myocardial perfusion adds value to conventional stress echocardiography by increasing its sensitivity for the detection of functionally abnormal myocardial perfusion. Myocardial contrast echocardiography and wall motion together provide higher sensitivity and accuracy for detection of CAD compared with SPECT.
Amitai, Isabella; Werner, Stephanie; Schicke, Bernd; Burmester, Gerd-Rüdiger; Minet, Olaf; Zabaryło, Urszula; Backhaus, Marina; Ohrndorf, Sarah
2015-09-01
Lightscan is a novel, rapid, low-cost, easily operated and noninvasive imaging technology used to assess inflammatory activity in proximal interphalangeal (PIP) joints. The results are calculated automatically. To our knowledge, this is the first comparative study of photo optical imaging (POI), with clinical examination (CE), disease activity score at 28 joints (DAS28)-erythrocyte sedimentation rate (ESR), and musculoskeletal ultrasonography (US) in healthy subjects and patients with rheumatoid arthritis (RA) or osteoarthritis (OA). There were 688 PIP joints of both hands examined in 87 subjects (38 RA, 21 OA, 28 healthy) by Lightscan and compared with CE for clinically swollen and tender joints, DAS28-ESR (only RA), and US. With US as reference, POI had a sensitivity of 74% and a specificity of 93%. In the receiver-operating curve (ROC) analysis, the Lightscan showed a higher sensitivity and specificity [area under the curve (AUC) 0.879] for the distinction of healthy subjects versus patients (OA, RA) than US in greyscale (GSUS; AUC 0.797) and power Doppler (PDUS; AUC 0.67). POI correlated significantly with GSUS (r 0.473, p < 0.01) and PDUS (r 0.486, p < 0.01). The agreement rates between POI and GSUS were up to 79%, between POI and PDUS up to 92%, and between POI and CE up to 66%. POI did not correlate with DAS28-ESR. The Lightscan is a new technology offering sensitive imaging detection of inflammatory changes in subjects with RA and OA with PIP arthritis. POI was more sensitive than CE and correlated significantly to GSUS and PDUS, while presenting a higher sensitivity and specificity for the detection of healthy subjects versus patients (RA, OA) based on the ROC analysis.
NASA Astrophysics Data System (ADS)
Funk, Daniel
2015-04-01
Climate variability poses major challenges for decision-makers in climate-sensitive sectors. Seasonal to decadal (S2D) forecasts provide potential value for management decisions especially in the context of climate change where information from present or past climatology loses significance. However, usable and decision-relevant tailored climate forecasts are still sparse for Europe and successful examples of application require elaborate and individual producer-user interaction. The assessment of sector-specific vulnerabilities to critical climate conditions at specific temporal scale will be a great step forward to increase the usability and efficiency of climate forecasts. A concept for a sector-specific vulnerability assessment (VA) to climate variability is presented. The focus of this VA is on the provision of usable vulnerability information which can be directly incorporated in decision-making processes. This is done by developing sector-specific climate-impact-decision-pathways and the identification of their specific time frames using data from both bottom-up and top-down approaches. The structure of common VA's for climate change related issues is adopted which envisages the determination of exposure, sensitivity and coping capacity. However, the application of the common vulnerability components within the context of climate service application poses some fundamental considerations: Exposure - the effect of climate events on the system of concern may be modified and delayed due to interconnected systems (e.g. catchment). The critical time-frame of a climate event or event sequence is dependent on system-internal thresholds and initial conditions. But also on decision-making processes which require specific lead times of climate information to initiate respective coping measures. Sensitivity - in organizational systems climate may pose only one of many factors relevant for decision making. The scope of "sensitivity" in this concept comprises both the potential physical response of the system of concern as well as the criticality of climate-related decision-making processes. Coping capacity - in an operational context coping capacity can only reduce vulnerability if it can be applied purposeful. With respect to climate vulnerabilities this refers to the availability of suitable, usable and skillful climate information. The focus for this concept is on existing S2D climate service products and their match with user needs. The outputs of the VA are climate-impact-decision-pathways which characterize critical climate conditions, estimate the role of climate in decision-making processes and evaluate the availability and potential usability of S2D climate forecast products. A classification scheme is developed for each component of the impact-pathway to assess its specific significance. The systemic character of these schemes enables a broad application of this VA across sectors where quantitative data is limited. This concept is developed and will be tested within the context of the EU-FP7 project "European Provision Of Regional Impacts Assessments on Seasonal and Decadal Timescales" EUPORIAS.
Combination of the non-invasive tests for the diagnosis of endometriosis.
Nisenblat, Vicki; Prentice, Lucy; Bossuyt, Patrick M M; Farquhar, Cindy; Hull, M Louise; Johnson, Neil
2016-07-13
About 10% of women of reproductive age suffer from endometriosis, a costly chronic disease causing pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but is expensive and carries surgical risks. Currently, there are no non-invasive tests available in clinical practice to accurately diagnose endometriosis. This review assessed the diagnostic accuracy of combinations of different non-invasive testing modalities for endometriosis and provided a summary of all the reviews in the non-invasive tests for endometriosis series. To estimate the diagnostic accuracy of any combination of non-invasive tests for the diagnosis of pelvic endometriosis (peritoneal and/or ovarian or deep infiltrating) compared to surgical diagnosis as a reference standard. The combined tests were evaluated as replacement tests for diagnostic surgery and triage tests to assist decision-making to undertake diagnostic surgery for endometriosis. We did not restrict the searches to particular study designs, language or publication dates. We searched CENTRAL to July 2015, MEDLINE and EMBASE to May 2015, as well as the following databases to April 2015: CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, DARE and PubMed. We considered published, peer-reviewed, randomised controlled or cross-sectional studies of any size, including prospectively collected samples from any population of women of reproductive age suspected of having one or more of the following target conditions: ovarian, peritoneal or deep infiltrating endometriosis (DIE). We included studies comparing the diagnostic test accuracy of a combination of several testing modalities with the findings of surgical visualisation of endometriotic lesions. Three review authors independently collected and performed a quality assessment of the data from each study by using the QUADAS-2 tool. For each test, the data were classified as positive or negative for the surgical detection of endometriosis and sensitivity and specificity estimates were calculated. The bivariate model was planned to obtain pooled estimates of sensitivity and specificity whenever sufficient data were available. The predetermined criteria for a clinically useful test to replace diagnostic surgery were a sensitivity of 0.94 and a specificity of 0.79 to detect endometriosis. We set the criteria for triage tests at a sensitivity of 0.95 and above and a specificity of 0.50 and above, which 'rules out' the diagnosis with high accuracy if there is a negative test result (SnOUT test), or a sensitivity of 0.50 and above and a specificity of 0.95 and above, which 'rules in' the diagnosis with high accuracy if there is a positive result (SpIN test). Eleven eligible studies included 1339 participants. All the studies were of poor methodological quality. Seven studies evaluated pelvic endometriosis, one study considered DIE and/or ovarian endometrioma, two studies differentiated endometrioma from other ovarian cysts and one study addressed mapping DIE at specific anatomical sites. Fifteen different diagnostic combinations were assessed, including blood, urinary or endometrial biomarkers, transvaginal ultrasound (TVUS) and clinical history or examination. We did not pool estimates of sensitivity and specificity, as each study analysed independent combinations of the non-invasive tests.Tests that met the criteria for a replacement test were: a combination of serum IL-6 (cut-off >15.4 pg/ml) and endometrial PGP 9.5 for pelvic endometriosis (sensitivity 1.00 (95% confidence interval (CI) 0.91 to 1.00), specificity 0.93 (95% CI, 0.80, 0.98) and the combination of vaginal examination and transvaginal ultrasound (TVUS) for rectal endometriosis (sensitivity 0.96 (95% CI 0.86 to 0.99), specificity 0.98 (95% CI 0.94 to 1.00)). Tests that met the criteria for SpIN triage tests for pelvic endometriosis were: 1. a multiplication of urine vitamin-D-binding protein (VDBP) and serum CA-125 (cut-off >2755) (sensitivity 0.74 (95% CI 0.60 to 0.84), specificity 0.97 (95% CI 0.86 to 1.00)) and 2. a combination of history (length of menses), serum CA-125 (cut-off >35 U/ml) and endometrial leukocytes (sensitivity 0.61 (95% CI 0.54 to 0.69), specificity 0.95 (95% CI 0.91 to 0.98)). For endometrioma, the following combinations qualified as SpIN test: 1. TVUS and either serum CA-125 (cut-off ≥25 U/ml) or CA 19.9 (cut-off ≥12 U/ml) (sensitivity 0.79 (95% CI 0.64 to 0.91), specificity 0.97 (95% CI 0.91 to 1.00)); 2. TVUS and serum CA 19.9 (cut-off ≥12 U/ml) (sensitivity 0.54 (95% CI 0.37 to 0.70), specificity 0.97 (95% CI 0.91 to 1.0)); 3-4. TVUS and serum CA-125 (cut-off ≥20 U/ml or cut-off ≥25 U/ml) (sensitivity 0.69 (95% CI 0.49 to 0.85), specificity 0.96 (95% CI 0.88 to 0.99)); 5. TVUS and serum CA-125 (cut-off ≥35 U/ml) (sensitivity 0.52 (95% CI 0.33 to 0.71), specificity 0.97 (95% CI 0.90 to 1.00)). A combination of vaginal examination and TVUS reached the threshold for a SpIN test for obliterated pouch of Douglas (sensitivity 0.87 (95% CI 0.69 to 0.96), specificity 0.98 (95% CI 0.95 to 1.00)), vaginal wall endometriosis (sensitivity 0.82 (95% CI 0.60 to 0.95), specificity 0.99 (95% CI 0.97 to 1.0)) and rectovaginal septum endometriosis (sensitivity 0.88 (95% CI 0.47 to 1.00), specificity 0.99 (95% CI 0.96 to 1.00)).All the tests were evaluated in individual studies and displayed wide CIs. Due to the heterogeneity and high risk of bias of the included studies, the clinical utility of the studied combination diagnostic tests for endometriosis remains unclear. None of the biomarkers evaluated in this review could be evaluated in a meaningful way and there was insufficient or poor-quality evidence. Laparoscopy remains the gold standard for the diagnosis of endometriosis and using any non-invasive tests should only be undertaken in a research setting.
Ma, Chunming; Liu, Yue; Lu, Qiang; Lu, Na; Liu, Xiaoli; Tian, Yiming; Wang, Rui; Yin, Fuzai
2016-02-01
The blood pressure-to-height ratio (BPHR) has been shown to be an accurate index for screening hypertension in children and adolescents. The aim of the present study was to perform a meta-analysis to assess the performance of BPHR for the assessment of hypertension. Electronic and manual searches were performed to identify studies of the BPHR. After methodological quality assessment and data extraction, pooled estimates of the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, area under the receiver operating characteristic curve and summary receiver operating characteristics were assessed systematically. The extent of heterogeneity for it was assessed. Six studies were identified for analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio values of BPHR, for assessment of hypertension, were 96% [95% confidence interval (CI)=0.95-0.97], 90% (95% CI=0.90-0.91), 10.68 (95% CI=8.03-14.21), 0.04 (95% CI=0.03-0.07) and 247.82 (95% CI=114.50-536.34), respectively. The area under the receiver operating characteristic curve was 0.9472. The BPHR had higher diagnostic accuracies for identifying hypertension in children and adolescents.
Huan, Huan; Wang, Jinsheng; Zhai, Yuanzheng; Xi, Beidou; Li, Juan; Li, Mingxiao
2016-04-15
It has been proved that groundwater vulnerability assessment is an effective tool for groundwater protection. Nowadays, quantitative assessment methods for specific vulnerability are scarce due to limited cognition of complicated contaminant fate and transport processes in the groundwater system. In this paper, process-based simulation model for specific vulnerability to nitrate using 1D flow and solute transport model in the unsaturated vadose zone is presented for groundwater resource protection. For this case study in Jilin City of northeast China, rate constants of denitrification and nitrification as well as adsorption constants of ammonium and nitrate in the vadose zone were acquired by laboratory experiments. The transfer time at the groundwater table t50 was taken as the specific vulnerability indicator. Finally, overall vulnerability was assessed by establishing the relationship between groundwater net recharge, layer thickness and t50. The results suggested that the most vulnerable regions of Jilin City were mainly distributed in the floodplain of Songhua River and Mangniu River. The least vulnerable areas mostly appear in the second terrace and back of the first terrace. The overall area of low, relatively low and moderate vulnerability accounted for 76% of the study area, suggesting the relatively low possibility of suffering nitrate contamination. In addition, the sensitivity analysis showed that the most sensitive factors of specific vulnerability in the vadose zone included the groundwater net recharge rate, physical properties of soil medium and rate constants of nitrate denitrification. By validating the suitability of the process-based simulation model for specific vulnerability and comparing with index-based method by a group of integrated indicators, more realistic and accurate specific vulnerability mapping could be acquired by the process-based simulation model acquiring. In addition, the advantages, disadvantages, constraint conditions and applying prospects of the quantitative approach for specific vulnerability assessment were discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Aimi; Li, Panli; Liu, Qiufang; Song, Shaoli
2017-01-01
This study aimed to evaluate the diagnostic role of breast-specific gamma camera imaging (BSGI) with technetium-99m-methoxy isobutyl isonitrile ( 99m Tc-MIBI) and magnetic resonance imaging (MRI) in patients with breast cancer through a meta-analysis. Three reviewers searched articles published in medical journals before June 2016 in MEDLINE, EMBASE and Springer Databases; the references listed in original articles were also retrieved. We used the quality assessment of diagnostic accuracy studies (QUADAS) tool to assess the quality of the included studies. Heterogeneity, pooled sensitivity and specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC) curves were calculated by Meta-DiSc software to estimate the diagnostic performance of BSGI and MRI. Ten studies with 517 patients were included after meeting the inclusion criteria. We did a subgroup analysis of the same data type. The pooled sensitivities of BSGI and MRI were: 0.84 (95% CI, 0.79-0.88) and 0.89 (95% CI, 0.84-0.92) respectively, and the pooled specificities of BSGI and MRI were: 0.82 (95% CI, 0.74-0.88) and 0.39 (95% CI, 0.30-0.49) respectively. The areas under the SROC curve of BSGI and MRI were 0.93 and 0.72 respectively. The results of our meta-analysis indicated that compared with MRI, BSGI has similar sensitivity, higher specificity, better diagnostic performance, and can be widely used in clinical practice.
Gulshan, Varun; Peng, Lily; Coram, Marc; Stumpe, Martin C; Wu, Derek; Narayanaswamy, Arunachalam; Venugopalan, Subhashini; Widner, Kasumi; Madams, Tom; Cuadros, Jorge; Kim, Ramasamy; Raman, Rajiv; Nelson, Philip C; Mega, Jessica L; Webster, Dale R
2016-12-13
Deep learning is a family of computational methods that allow an algorithm to program itself by learning from a large set of examples that demonstrate the desired behavior, removing the need to specify rules explicitly. Application of these methods to medical imaging requires further assessment and validation. To apply deep learning to create an algorithm for automated detection of diabetic retinopathy and diabetic macular edema in retinal fundus photographs. A specific type of neural network optimized for image classification called a deep convolutional neural network was trained using a retrospective development data set of 128 175 retinal images, which were graded 3 to 7 times for diabetic retinopathy, diabetic macular edema, and image gradability by a panel of 54 US licensed ophthalmologists and ophthalmology senior residents between May and December 2015. The resultant algorithm was validated in January and February 2016 using 2 separate data sets, both graded by at least 7 US board-certified ophthalmologists with high intragrader consistency. Deep learning-trained algorithm. The sensitivity and specificity of the algorithm for detecting referable diabetic retinopathy (RDR), defined as moderate and worse diabetic retinopathy, referable diabetic macular edema, or both, were generated based on the reference standard of the majority decision of the ophthalmologist panel. The algorithm was evaluated at 2 operating points selected from the development set, one selected for high specificity and another for high sensitivity. The EyePACS-1 data set consisted of 9963 images from 4997 patients (mean age, 54.4 years; 62.2% women; prevalence of RDR, 683/8878 fully gradable images [7.8%]); the Messidor-2 data set had 1748 images from 874 patients (mean age, 57.6 years; 42.6% women; prevalence of RDR, 254/1745 fully gradable images [14.6%]). For detecting RDR, the algorithm had an area under the receiver operating curve of 0.991 (95% CI, 0.988-0.993) for EyePACS-1 and 0.990 (95% CI, 0.986-0.995) for Messidor-2. Using the first operating cut point with high specificity, for EyePACS-1, the sensitivity was 90.3% (95% CI, 87.5%-92.7%) and the specificity was 98.1% (95% CI, 97.8%-98.5%). For Messidor-2, the sensitivity was 87.0% (95% CI, 81.1%-91.0%) and the specificity was 98.5% (95% CI, 97.7%-99.1%). Using a second operating point with high sensitivity in the development set, for EyePACS-1 the sensitivity was 97.5% and specificity was 93.4% and for Messidor-2 the sensitivity was 96.1% and specificity was 93.9%. In this evaluation of retinal fundus photographs from adults with diabetes, an algorithm based on deep machine learning had high sensitivity and specificity for detecting referable diabetic retinopathy. Further research is necessary to determine the feasibility of applying this algorithm in the clinical setting and to determine whether use of the algorithm could lead to improved care and outcomes compared with current ophthalmologic assessment.
De Souza, Aglecio Luiz; Batista, Gisele Almeida; Alegre, Sarah Monte
2017-01-01
We compare spectral analysis of photoplethysmography (PTG) with insulin resistance measured by the hyperinsulinemic euglycemic clamp (HEC) technique. A total of 100 nondiabetic subjects, 43 men and 57 women aged 20-63years, 30 lean, 42 overweight and 28 obese were enrolled in the study. These patients underwent an examination with HEC, and an examination with the PTG spectral analysis and calculation of the PTG Total Power (PTG-TP). Receiver-operating characteristic (ROC) curves were constructed to determine the specificity and sensitivity of PTG-TP in the assessment of insulin resistance. There is a moderate correlation between insulin sensitivity (M-value) and PTG-TP (r=- 0.64, p<0.0001). The ROC curves showed that the most relevant cutoff to the whole study group was a PTG-TP>406.2. This cut-off had a sensitivity=95.7%, specificity =84,4% and the area under the ROC curve (AUC)=0.929 for identifying insulin resistance. All AUC ROC curve analysis were significant (p<0.0001). The use of the PTG-TP marker measured from the PTG spectral analysis is a useful tool in screening and follow up of IR, especially in large-scale studies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Falls risk assessment outcomes and factors associated with falls for older Indigenous Australians.
Hill, Keith D; Flicker, Leon; LoGiudice, Dina; Smith, Kate; Atkinson, David; Hyde, Zoë; Fenner, Stephen; Skeaf, Linda; Malay, Roslyn; Boyle, Eileen
2016-12-01
To describe the prevalence of falls and associated risk factors in older Indigenous Australians, and compare the accuracy of validated falls risk screening and assessment tools in this population in classifying fall status. Cross-sectional study of 289 Indigenous Australians aged ≥45 years from the Kimberley region of Western Australia who had a detailed assessment including self-reported falls in the past year (n=289), the adapted Elderly Falls Screening Tool (EFST; n=255), and the Falls Risk for Older People-Community (FROP-Com) screening tool (3 items, n=74) and FROP-Com falls assessment tool (n=74). 32% of participants had ≥1 fall in the preceding year, and 37.3% were classified high falls risk using the EFST (cut-off ≥2). In contrast, for the 74 participants assessed with the FROP-Com, only 14.9% were rated high risk, 35.8% moderate risk, and 49.3% low risk. The FROP-Com screen and assessment tools had the highest classification accuracy for identifying fallers in the preceding year (area under curve >0.85), with sensitivity/specificity highest for the FROP-Com assessment (cut-off ≥12), sensitivity=0.84 and specificity=0.73. Falls are common in older Indigenous Australians. The FROP-Com falls risk assessment tool appears useful in this population, and this research suggests changes that may improve its utility further. © 2016 Public Health Association of Australia.
Rapid assessment method for prevalence and intensity of Loa loa infection.
Takougang, Innocent; Meremikwu, Martin; Wandji, Samuel; Yenshu, Emmanuel V.; Aripko, Ben; Lamlenn, Samson B.; Eka, Braide L.; Enyong, Peter; Meli, Jean; Kale, Oladele; Remme, Jan H.
2002-01-01
OBJECTIVE: To assess the validity of observations on eye worm and Calabar swellings for the rapid assessment of the prevalence and intensity of loiasis at the community level. METHOD: A total of 12895 individuals over the age of 15 years living in 102 communities in Cameroon and Nigeria took part in the study. A standardized questionnaire was administered to participants from whom finger-prick blood samples were collected and examined for Loa loa microfilariae. Rapid assessments of the prevalence and intensity of loiasis were made on the basis of a history of eye worm or Calabar swellings. FINDINGS: There was a strong correlation between the indices of the rapid assessment procedures and the parasitological indices of L. loa endemicity. The rapid assessment indices were effective in diagnosing high-risk communities (sensitivity 94-100%; specificity 66-92%). The highest sensitivity (100%) and specificity (92%) were obtained with a rapid assessment procedure based on a history of eye worm lasting 1-7 days together with confirmation by the guided recognition of a photograph of adult L. loa in the eye. CONCLUSION: Rapid assessment of the prevalence and intensity of loiasis at the community level can be achieved using a procedure based on the history of eye worm lasting 1-7 days together with confirmation by the guided recognition of a photograph of an adult L. loa in the eye. PMID:12481206
Pelletier, Stéphanie; Alarcon, Régis; Ewert, Valérie; Forest, Margot; Nalpas, Bertrand; Perney, Pascal
2018-06-01
Screening of cognitive impairment is a major challenge in alcoholics seeking treatment, since cognitive dysfunction may impair the overall efficacy of rehabilitation programs and consequently increase relapse rate. We compared the performance of two screening tools: the MoCA (Montreal Cognitive Assessment), which is widely used in patients with neurological diseases and already used in patients with alcohol use disorder (AUD), and the BEARNI (Brief Evaluation of Alcohol-Related Neuropsychological Impairments), a recent test specifically developed for the alcoholic population. We compared the sensitivity and specificity of the MoCA and the BEARNI in a sample of AUD patients with and without cognitive impairment assessed by a battery of neuropsychological tests. Ninety patients were included. There were 67 men and 23 women aged 48.9 ± 9.6 years. According to the neuropsychological tests, 51.1% of patients had no cognitive impairment, while it was mild or moderate to severe in 31.1 and 17.8%, respectively. The BEARNI sensitivity was extremely high (1.0), since all patients with cognitive impairment were identified, but its specificity was very low (0.04). The MoCA had a lower sensitivity (0.79) than the BEARNI, but its specificity was significantly better (0.65). A detailed analysis of the BEARNI scores showed a discrepancy between the qualitative and quantitative interpretation of the test which could, at least in part, explain its low specificity. Both the MoCA and the BEARNI are screening tools which identified alcoholic patients with cognitive impairment. However, in routine use, the MoCA appeared to be more appropriate given the low specificity of the BEARNI. Copyright © 2018 Elsevier B.V. All rights reserved.
Implementation of Novel Design Features for qPCR-Based eDNA Assessment
Veldhoen, Nik; Hobbs, Jared; Ikonomou, Georgios; Hii, Michael; Lesperance, Mary; Helbing, Caren C.
2016-01-01
Environmental stewardship requires timely, accurate information related to the status of a given ecosystem and the species that occupy it. Recent advances in the application of the highly sensitive real-time quantitative polymerase chain reaction (qPCR) towards identification of constituents within environmental DNA (eDNA) now allow targeted detection of the presence of species-specific biological material within a localized geographic region. However, as with all molecular techniques predicated on the specificity and sensitivity of the PCR assay, careful validation of each eDNA qPCR assay in development must be performed both under controlled laboratory conditions and when challenged with field-derived eDNA samples. Such a step-wise approach forms the basis for incorporation of innovative qPCR design features that strengthen the implementation and interpretation of the eDNA assay. This includes empirical determination that the qPCR assay is refractory to the presence of human DNA and the use of a tripartite assay approach comprised of 1) a primer set targeting plant chloroplast that evaluates the presence of amplifiable DNA from field samples to increase confidence in a negative result, 2) an animal group primer set to increase confidence in the assay result, and 3) a species-specific primer set to assess presence of DNA from the target species. To demonstrate this methodology, we generated eDNA assays specific for the North American bullfrog (Lithobates (Rana) catesbeiana) and the Rocky Mountain tailed frog (Ascaphus montanus) and characterized each with respect to detection sensitivity and specificity with demonstrated performance in a field survey scenario. The qPCR design features presented herein address specific challenges of eDNA assays thereby increasing their interpretative power. PMID:27802293
Hadjab, I; Sim, S; Karhula, S S; Kauppinen, S; Garon, M; Quenneville, E; Lavigne, P; Lehenkari, P P; Saarakkala, S; Buschmann, M D
2018-03-01
To evaluate cross-correlations of ex vivo electromechanical properties with cartilage and subchondral bone plate thickness, as well as their sensitivity and specificity regarding early cartilage degeneration in human tibial plateau. Six pairs of tibial plateaus were assessed ex vivo using an electromechanical probe (Arthro-BST) which measures a quantitative parameter (QP) reflecting articular cartilage compression-induced streaming potentials. Cartilage thickness was then measured with an automated thickness mapping technique using Mach-1 multiaxial mechanical tester. Subsequently, a visual assessment was performed by an experienced orthopedic surgeon using the International Cartilage Repair Society (ICRS) grading system. Each tibial plateau was finally evaluated with μCT scanner to determine the subchondral-bone plate thickness over the entire surface. Cross-correlations between assessments decreased with increasing degeneration level. Moreover, electromechanical QP and subchondral-bone plate thickness increased strongly with ICRS grade (ρ = 0.86 and ρ = 0.54 respectively), while cartilage thickness slightly increased (ρ = 0.27). Sensitivity and specificity analysis revealed that the electromechanical QP is the most performant to distinguish between different early degeneration stages, followed by subchondral-bone plate thickness and then cartilage thickness. Lastly, effect sizes of cartilage and subchondral-bone properties were established to evaluate whether cartilage or bone showed the most noticeable changes between normal (ICRS 0) and each early degenerative stage. Thus, the effect sizes of cartilage electromechanical QP were almost twice those of the subchondral-bone plate thickness, indicating greater sensitivity of electromechanical measurements to detect early osteoarthritis. The potential of electromechanical properties for the diagnosis of early human cartilage degeneration was highlighted and supported by cartilage thickness and μCT assessments. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Mast cell activation test in the diagnosis of allergic disease and anaphylaxis.
Bahri, Rajia; Custovic, Adnan; Korosec, Peter; Tsoumani, Marina; Barron, Martin; Wu, Jiakai; Sayers, Rebekah; Weimann, Alf; Ruiz-Garcia, Monica; Patel, Nandinee; Robb, Abigail; Shamji, Mohamed H; Fontanella, Sara; Silar, Mira; Mills, E N Clare; Simpson, Angela; Turner, Paul J; Bulfone-Paus, Silvia
2018-03-05
Food allergy is an increasing public health issue and the most common cause of life-threatening anaphylactic reactions. Conventional allergy tests assess for the presence of allergen-specific IgE, significantly overestimating the rate of true clinical allergy and resulting in overdiagnosis and adverse effect on health-related quality of life. To undertake initial validation and assessment of a novel diagnostic tool, we used the mast cell activation test (MAT). Primary human blood-derived mast cells (MCs) were generated from peripheral blood precursors, sensitized with patients' sera, and then incubated with allergen. MC degranulation was assessed by means of flow cytometry and mediator release. We compared the diagnostic performance of MATs with that of existing diagnostic tools to assess in a cohort of peanut-sensitized subjects undergoing double-blind, placebo-controlled challenge. Human blood-derived MCs sensitized with sera from patients with peanut, grass pollen, and Hymenoptera (wasp venom) allergy demonstrated allergen-specific and dose-dependent degranulation, as determined based on both expression of surface activation markers (CD63 and CD107a) and functional assays (prostaglandin D 2 and β-hexosaminidase release). In this cohort of peanut-sensitized subjects, the MAT was found to have superior discrimination performance compared with other testing modalities, including component-resolved diagnostics and basophil activation tests. Using functional principle component analysis, we identified 5 clusters or patterns of reactivity in the resulting dose-response curves, which at preliminary analysis corresponded to the reaction phenotypes seen at challenge. The MAT is a robust tool that can confer superior diagnostic performance compared with existing allergy diagnostics and might be useful to explore differences in effector cell function between basophils and MCs during allergic reactions. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Ko, Hae-Youn; Kang, Si-Mook; Kim, Hee Eun; Kwon, Ho-Keun; Kim, Baek-Il
2015-05-01
Detection of approximal caries lesions can be difficult due to their anatomical position. This study aimed to assess the ability of the quantitative light-induced fluorescence-digital (QLF-D) in detecting approximal caries, and to compare the performance with those of the International Caries Detection and Assessment System II (ICDAS II) and digital radiography (DR). Extracted permanent teeth (n=100) were selected and mounted in pairs. The simulation pairs were assessed by one calibrated dentist using each detection method. After all the examinations, the teeth (n=95) were sectioned and examined histologically as gold standard. The modalities were compared in terms of sensitivity, specificity, areas under receiver operating characteristic curves (AUROC) for enamel (D1) and dentine (D3) levels. The intra-examiner reliability was assessed for all modalities. At D1 threshold, the ICDAS II presented the highest sensitivity (0.80) while the DR showed the highest specificity (0.89); however, the methods with the greatest AUC values at D1 threshold were DR and QLF-D (0.80 and 0.80 respectively). At D3 threshold, the methods with the highest sensitivity were ICDAS II and QLF-D (0.64 and 0.64 respectively) while the method with the lowest sensitivity was DR (0.50). However, with regard to the AUC values at D3 threshold, the QLF-D presented the highest value (0.76). All modalities showed to have excellent intra-examiner reliability. The newly developed QLF-D was not only able to detect proximal caries, but also showed to have comparable performance to the visual inspection and radiography in detecting proximal caries. QLF-D has the potential to be a useful detection method for proximal caries. Copyright © 2015 Elsevier Ltd. All rights reserved.
Yeung, P Y; Wong, L L; Chan, C C; Leung, Jess L M; Yung, C Y
2014-12-01
To validate the Hong Kong version of Montreal Cognitive Assessment (HK-MoCA) in identification of mild cognitive impairment and dementia in Chinese older adults. Cross-sectional study. Cognition clinic and memory clinic of a public hospital in Hong Kong. A total of 272 participants (dementia, n=130; mild cognitive impairment, n=93; normal controls, n=49) aged 60 years or above were assessed using HK-MoCA. The HK-MoCA scores were validated against expert diagnosis according to the Diagnostic and Statistical Manual of Mental Disorders (4th ed) criteria for dementia and Petersen's criteria for mild cognitive impairment. Statistical analysis was performed using receiver operating characteristic curve and regression analyses. Additionally, comparison was made with the Cantonese version of Mini-Mental State Examination and Global Deterioration Scale. The optimal cutoff score for the HK-MoCA to differentiate cognitive impaired persons (mild cognitive impairment and dementia) from normal controls was 21/22 after adjustment of education level, giving a sensitivity of 0.928, specificity of 0.735, and area under the curve of 0.920. Moreover, the cutoff to detect mild cognitive impairment was 21/22 with a sensitivity of 0.828, specificity of 0.735, and area under the curve of 0.847. Score of the Cantonese version of the Mini-Mental State Examination to detect mild cognitive impairment was 26/27 with a sensitivity of 0.785, specificity of 0.816, and area under the curve of 0.857. At the optimal cutoff of 18/19, HK-MoCA identified dementia from controls with a sensitivity of 0.923, specificity of 0.918, and area under the curve of 0.971. The HK-MoCA is a useful cognitive screening instrument for use in Chinese older adults in Hong Kong. A score of less than 22 should prompt further diagnostic assessment. It has comparable sensitivity with the Cantonese version of Mini-Mental State Examination for detection of mild cognitive impairment. It is brief and feasible to conduct in the clinical setting, and can be completed in less than 15 minutes. Thus, HK-MoCA provides an attractive alternative screening instrument to Mini-Mental State Examination which has ceiling effect (ie may fail to detect mild/moderate cognitive impairment in people with high education level or premorbid intelligence) and needs to be purchased due to copyright issues.
Evaluation of YB-1 levels in patients with endometriosis.
Ahrens, Thorben; Silveira, Cassia G T; Banz-Jansen, Constanze; Rody, Achim; Hornung, Daniela
2015-08-01
The objective of this study is the evaluation of serum YB-1 levels in the diagnosis of endometriosis. Serum samples of 12 patients with histologically confirmed endometriosis and of 10 control patients were collected. Western blot analysis was used to assess serum YB-1 levels. Groups were compared with Student's t-test or, if not normally distributed, with the Mann-Whitney test. Sensitivity and specificity for the potential diagnostic performance of serum YB-1 were assessed by receiver operating characteristic (ROC) curves. Serum YB-1 levels were significantly higher in patients with endometriosis (=0.004). The area under the curve was 0.867 (95% confidence interval 0.714-1.019) with sensitivity and specificity of 83.3% and 70% respectively. Serum YB-1 levels in patients with endometriosis are significantly higher compared to control patients and may be used as a potential diagnostic biomarker for endometriosis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
A PTSD Screen for Forensic Populations.
Guston, Kaitlin; Combs, Elizabeth; Kopak, Albert; Raggio, Alyssa; Hoffmann, Norman
2018-06-01
Posttraumatic stress disorder (PTSD) has been observed in a sizable proportion of the U.S. adult correctional population. Jail administrators must pay particularly close attention to inmates with PTSD symptoms, considering these facilities serve as the gateway to the criminal justice system and inmates with PTSD may pose a risk to themselves, other inmates, and staff. The reality of conducting behavioral health assessments in a jail environment is wrought with significant challenges, including limited time. The current study examined prior research on PTSD screening tools to establish an empirical basis for a practical screen to be used among adults recently booked into local jails. Data from a random sample of 283 adults assessed specificity and sensitivity rates of different combinations of criteria. Results indicated a two-item screen achieved an 86.4% sensitivity rate as well as an 80.4% specificity rate. This evidence demonstrates a practical and clinically relevant approach to conducting PTSD screens among adult jail inmates.
Paul, Shashi B; Das, Prasenjit; Mahanta, Mousumi; Sreenivas, Vishnubhatla; Kedia, Saurabh; Kalra, Nancy; Kaur, Harpreet; Vijayvargiya, Maneesh; Ghosh, Shouriyo; Gamanagatti, Shivanand R; Shalimar; Gupta, Siddhartha Dutta; Acharya, Subrat K
2017-12-01
To evaluate the diagnostic accuracy of shear wave elastography (SWE) and transient elastography (TE) in the evaluation of liver fibrosis in chronic hepatitis B (CHB) and C (CHC) patients taking liver biopsy as gold standard. Ethics committee approved this prospective cross-sectional study. Between October 2012 and December 2014, consecutive CHB/CHC patients fulfilling the inclusion criteria were included-age more than 18 years, informed written consent, willing and suitable for liver biopsy. SWE, TE, and biopsy were performed the same day. Liver stiffness measurement (LSM) cut-offs for various stages of fibrosis were generated for SWE and TE. AUC, sensitivity, specificity, and positive/negative predictive values were estimated individually or in combination. CH patients (n = 240, CHB 172, CHC 68), 176 males, 64 females, mean age 32.6 ± 11.6 years were enrolled. Mean LSM of patients with no histological fibrosis (F0) was 5.0 ± 0.7 and 5.1+1.4 kPa on SWE and TE, respectively. For differentiating F2 and F3-4 fibrosis on SWE, at 7.0 kPa cut-off, the sensitivity was 81.3% and specificity 77.6%. For TE, at 8.3 kPa cut-off, sensitivity was 81.8% and specificity 83.1%. For F3 vs. F4, SWE sensitivity was 83.3% and specificity 90.7%. At 14.8 kPa cut-off, TE showed similar sensitivity (83.3%) but specificity increased to 96.5%. Significant correlation between SWE and TE was observed (r = 0.33, p < 0.001). On combining SWE and TE, a drop in sensitivity with increased specificity for all stages of liver fibrosis occured. SWE is an accurate technique for evaluating liver fibrosis. SWE compares favorably with TE especially for predicting advanced fibrosis/cirrhosis. Combining SWE and TE further improves specificity.