Glukhov, Alexey V.; Kalyanasundaram, Anuradha; Lou, Qing; Hage, Lori T.; Hansen, Brian J.; Belevych, Andriy E.; Mohler, Peter J.; Knollmann, Björn C.; Periasamy, Muthu; Györke, Sandor; Fedorov, Vadim V.
2015-01-01
Aims Loss-of-function mutations in Calsequestrin 2 (CASQ2) are associated with catecholaminergic polymorphic ventricular tachycardia (CPVT). CPVT patients also exhibit bradycardia and atrial arrhythmias for which the underlying mechanism remains unknown. We aimed to study the sinoatrial node (SAN) dysfunction due to loss of CASQ2. Methods and results In vivo electrocardiogram (ECG) monitoring, in vitro high-resolution optical mapping, confocal imaging of intracellular Ca2+ cycling, and 3D atrial immunohistology were performed in wild-type (WT) and Casq2 null (Casq2−/−) mice. Casq2−/− mice exhibited bradycardia, SAN conduction abnormalities, and beat-to-beat heart rate variability due to enhanced atrial ectopic activity both at baseline and with autonomic stimulation. Loss of CASQ2 increased fibrosis within the pacemaker complex, depressed primary SAN activity, and conduction, but enhanced atrial ectopic activity and atrial fibrillation (AF) associated with macro- and micro-reentry during autonomic stimulation. In SAN myocytes, CASQ2 deficiency induced perturbations in intracellular Ca2+ cycling, including abnormal Ca2+ release, periods of significantly elevated diastolic Ca2+ levels leading to pauses and unstable pacemaker rate. Importantly, Ca2+ cycling dysfunction occurred not only at the SAN cellular level but was also globally manifested as an increased delay between action potential (AP) and Ca2+ transient upstrokes throughout the atrial pacemaker complex. Conclusions Loss of CASQ2 causes abnormal sarcoplasmic reticulum Ca2+ release and selective interstitial fibrosis in the atrial pacemaker complex, which disrupt SAN pacemaking but enhance latent pacemaker activity, create conduction abnormalities and increase susceptibility to AF. These functional and extensive structural alterations could contribute to SAN dysfunction as well as AF in CPVT patients. PMID:24216388
Unudurthi, Sathya D.; Wolf, Roseanne M.; Hund, Thomas J.
2014-01-01
Normal heart rhythm (sinus rhythm) depends on regular activity of the sinoatrial node (SAN), a heterogeneous collection of specialized myocytes in the right atrium. SAN cells, in general, possess a unique electrophysiological profile that promotes spontaneous electrical activity (automaticity). However, while automaticity is required for normal pacemaking, it is not necessarily sufficient. Less appreciated is the importance of the elaborate structure of the SAN complex for proper pacemaker function. Here, we review the important structural features of the SAN with a focus on how these elements help manage a precarious balance between electrical charge generated by the SAN (“source”) and the charge needed to excite the surrounding atrial tissue (“sink”). We also discuss how compromised “source-sink” balance due, for example to fibrosis, may promote SAN dysfunction, characterized by slow and/or asynchronous pacemaker activity and even failure, in the setting of cardiovascular disease (e.g., heart failure, atrial fibrillation). Finally, we discuss implications of the “source-sink” balance in the SAN complex for cell and gene therapies aimed at creating a biological pacemaker as replacement or bridge to conventional electronic pacemakers. PMID:25505419
Hybrid Therapy in the Management of Atrial Fibrillation
Stárek, Zdeněk; Lehar, František; Jež, Jiří; Wolf, Jiří; Novák, Miroslav
2015-01-01
Atrial fibrillation is the most common sustained arrhythmia. Because of the sub-optimal outcomes and associated risks of medical therapy as well as the recent advances in non-pharmacologic strategies, a multitude of combined (hybrid) algorithms have been introduced that improve efficacy of standalone therapies while maintaining a high safety profile. Antiarrhythmic administration enhances success rate of electrical cardioversion. Catheter ablation of antiarrhythmic drug-induced typical atrial flutter may prevent recurrent atrial fibrillation. Through simple ablation in the right atrium, suppression of atrial fibrillation may be achieved in patients with previously ineffective antiarrhythmic therapy. Efficacy of complex catheter ablation in the left atrium is improved with antiarrhythmic drugs. Catheter ablation followed by permanent pacemaker implantation is an effective and safe treatment option for selected patients. Additional strategies include pacing therapies such as atrial pacing with permanent pacemakers, preventive pacing algorithms, and/or implantable dual-chamber defibrillators are available. Modern hybrid strategies combining both epicardial and endocardial approaches in order to create a complex set of radiofrequency lesions in the left atrium have demonstrated a high rate of success and warrant further research. Hybrid therapy for atrial fibrillation reviews history of development of non-pharmacological treatment strategies and outlines avenues of ongoing research in this field. PMID:25028165
Matusik, Paweł; Woznica, Natalia; Lelakowsk, Jacek
2010-05-01
Atrial fibrillation (AF) is a frequent problem of patients with pacemakers, and depends not only on disease but also on stimulation method. The aim of the study was to estimate the prevalence of AF before and after pacemaker implantation as well as to assess the influence of VVI and DDD cardiac pacing on onset of AF in patients with complete atrioventricularblock (AVB). We included 155 patients controlled between 2000 and 2008 in Pacemaker Clinic because of AVB III degree, treated with VVI or DDD pacemaker implantation. Information about the health status of the patients was gathered from medical documentation and analysis of clinical ambulatory electrocardiograms. The study group comprised of 68 women and 87 men, mean age 68.7 +/- 13.9 years during implantation. 69% of patients had VVI pacemaker. There were 72.3% of patients with sinus rhythm before pacemaker implantation. During follow-up 4 +/- 2.8 years in 19.6% cases onset of atrial fibrillation de novo was diagnosed (in 31.3% in VVI mode vs. 2.2% in DDD mode; p = 0.00014). Mean time to AF since implantation was approximately 2.5 years. In VVI group (21 persons) amounted 32.1 months, while in 1 patient with DDD pacemaker 18 months. Between group with AF after implantation and with sinus rhythm preserved there was no statistically significant difference in age or gender (p = 0.89512 and p = 0.1253, respectively). Prevalence of atrial fibrillation after pacemaker implantation increased to 40%. Atrial fibrillation is frequent in patients before and after pacemaker implantation, especially in patients stimulated in VVI mode. Major possibility of atrial fibrillation onset after pacemaker implantation should result in more attention during routine ECG examination.
Khurwolah, Mohammad Reeaze; Vezi, Brian Zwelethini
In the daily practice of pacemaker insertion, the occurrence of atrial and ventricular lead switch at the pacemaker box header is a rare and unintentional phenomenon, with less than five cases reported in the literature. The lead switch may have dire consequences, depending on the indication for the pacemaker. One of these consequences is pacemaker syndrome, in which the normal sequence of atrial and ventricular activation is impaired, leading to sub-optimal ventricular filling and cardiac output. It is important for the attending physician to recognise any worsening of symptoms in a patient who has recently had a permanent pacemaker inserted. In the case of a dual-chamber pacemaker, switching of the atrial and ventricular leads at the pacemaker box header should be strongly suspected. We present an unusual case of pacemaker syndrome and right ventricular-only pacinginduced left ventricular systolic dysfunction in a patient with a dual-chamber pacemaker.
Armour, J Andrew; Richer, Louis-Philippe; Pagé, Pierre; Vinet, Alain; Kus, Teresa; Vermeulen, Michel; Nadeau, Réginald; Cardinal, René
2005-03-31
We sought to determine the sites of origin of atrial tachyarrhythmias induced by activating mediastinal nerves, as well as the response of such arrhythmias to autonomic modulation. Under general anaesthesia, atrioventricular block was induced after thoracotomy in 19 canines. Brief trains of 5 electrical stimuli were delivered to right-sided mediastinal nerves during the atrial refractory period. Unipolar electrograms were recorded from 191 right and left atrial epicardial sites under several conditions, i.e. (i) with intact nervous systems and following (ii) acute decentralization of the intrathoracic nervous system or administration of (iii) atropine, (iv) timolol, (v) hexamethonium. Concomitant right atrial endocardial mapping was performed in 7 of these dogs. Mediastinal nerve stimulation consistently initiated bradycardia followed by atrial tachyarrhythmias. In the initial tachyarrhythmia beats, early epicardial breakthroughs were identified in the right atrial free wall (28/50 episodes) or Bachmann bundle region (22/50), which corresponded to endocardial sites of origin associated with the right atrial subsidiary pacemaker complex, i.e. the crista terminalis and dorsal locations including the right atrial aspect of the interatrial septum. Neuronally induced responses were eliminated by atropine, modified by timolol and unaffected by acute neuronal decentralization. After hexamethonium, responses to extra-pericardial but not intra-pericardial nerve stimulation were eliminated. It is concluded that concomitant activation of cholinergic and adrenergic efferent intrinsic cardiac neurons induced by right-sided efferent neuronal stimulation initiates atrial tachyarrhythmias that originate from foci anatomically related to the right atrial pacemaker complex and tissues underlying major atrial ganglionated plexuses.
Edwards, Steven J; Karner, Charlotta; Trevor, Nicola; Wakefield, Victoria; Salih, Fatima
2015-08-01
Bradycardia [resting heart rate below 60 beats per minute (b.p.m.)] can be caused by conditions affecting the natural pacemakers of the heart, such as sick sinus syndrome (SSS) and atrioventricular (AV) blocks. People suffering from bradycardia may present with palpitations, exercise intolerance and fainting. The only effective treatment for patients suffering from symptomatic bradycardia is implantation of a permanent pacemaker. To appraise the clinical effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber atrial pacemakers for treating symptomatic bradycardia in people with SSS and no evidence of AV block. All databases (MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Health Technology Assessment database, NHS Economic Evaluations Database) were searched from inception to June 2014. A systematic review of the clinical and economic literature was carried out in accordance with the general principles published by the Centre for Reviews and Dissemination. Randomised controlled trials (RCTs) evaluating dual-chamber and single-chamber atrial pacemakers and economic evaluations were included. Pairwise meta-analysis was carried out. A de novo economic model was developed. Of 493 references, six RCTs were included in the review. The results were predominantly influenced by the largest trial DANPACE. Dual-chamber pacing was associated with a statistically significant reduction in reoperation [odds ratio (OR) 0.48, 95% confidence interval (CI) 0.36 to 0.63] compared with single-chamber atrial pacing. The difference is primarily because of the development of AV block requiring upgrade to a dual-chamber device. The risk of paroxysmal atrial fibrillation was also reduced with dual-chamber pacing compared with single-chamber atrial pacing (OR 0.75, 95% CI 0.59 to 0.96). No statistically significant difference was found between the pacing modes for mortality, heart failure, stroke, chronic atrial fibrillation or quality of life. However, the risk of developing heart failure may vary with age and device. The de novo economic model shows that dual-chamber pacemakers are more expensive and more effective than single-chamber atrial devices, resulting in a base-case incremental cost-effectiveness ratio (ICER) of £6506. The ICER remains below £20,000 in probabilistic sensitivity analysis, structural sensitivity analysis and most scenario analyses and one-way sensitivity analyses. The risk of heart failure may have an impact on the decision to use dual-chamber or single-chamber atrial pacemakers. Results from an analysis based on age (> 75 years or ≤ 75 years) and risk of heart failure indicate that dual-chamber pacemakers dominate single-chamber atrial pacemakers (i.e. are less expensive and more effective) in older patients, whereas dual-chamber pacemakers are dominated by (i.e. more expensive and less effective) single-chamber atrial pacemakers in younger patients. However, these results are based on a subgroup analysis and should be treated with caution. In patients with SSS without evidence of impaired AV conduction, dual-chamber pacemakers appear to be cost-effective compared with single-chamber atrial pacemakers. The risk of developing a complete AV block and the lack of tools to identify patients at high risk of developing the condition argue for the implantation of a dual-chamber pacemaker programmed to minimise unnecessary ventricular pacing. However, considerations have to be made around the risk of developing heart failure, which may depend on age and device. This study is registered as PROSPERO CRD42013006708. The National Institute for Health Research Health Technology Assessment programme.
Israel, Carsten W; Ekosso-Ejangue, Lucy; Sheta, Mohamed-Karim
2015-09-01
The key to a successful analysis of a pacemaker electrocardiogram (ECG) is the application of the systematic approach used for any other ECG without a pacemaker: analysis of (1) basic rhythm and rate, (2) QRS axis, (3) PQ, QRS and QT intervals, (4) morphology of P waves, QRS, ST segments and T(U) waves and (5) the presence of arrhythmias. If only the most obvious abnormality of a pacemaker ECG is considered, wrong conclusions can easily be drawn. If a systematic approach is skipped it may be overlooked that e.g. atrial pacing is ineffective, the left ventricle is paced instead of the right ventricle, pacing competes with intrinsic conduction or that the atrioventricular (AV) conduction time is programmed too long. Apart from this analysis, a pacemaker ECG which is not clear should be checked for the presence of arrhythmias (e.g. atrial fibrillation, atrial flutter, junctional escape rhythm and endless loop tachycardia), pacemaker malfunction (e.g. atrial or ventricular undersensing or oversensing, atrial or ventricular loss of capture) and activity of specific pacing algorithms, such as automatic mode switching, rate adaptation, AV delay modifying algorithms, reaction to premature ventricular contractions (PVC), safety window pacing, hysteresis and noise mode. A systematic analysis of the pacemaker ECG almost always allows a probable diagnosis of arrhythmias and malfunctions to be made, which can be confirmed by pacemaker control and can often be corrected at the touch of the right button to the patient's benefit.
Survival time with pacemaker implantation for dogs diagnosed with persistent atrial standstill.
Cervenec, R M; Stauthammer, C D; Fine, D M; Kellihan, H B; Scansen, B A
2017-06-01
To evaluate survival time in dogs with persistent atrial standstill after pacemaker implantation and to compare the survival times for cardiac-related vs. non-cardiac deaths. Secondary objectives were to evaluate the effects of breed and the presence of congestive heart failure (CHF) at the time of diagnosis on survival time. Twenty dogs with persistent atrial standstill and pacemaker implantation. Medical records were searched to identify dogs diagnosed with persistent atrial standstill based on electrocardiogram that underwent pacemaker implantation. Survival after pacemaker implantation was analyzed using the Kaplan-Meier method. The median survival time after pacemaker implantation for all-cause mortality was 866 days. There was no significant difference (p=0.573) in median survival time for cardiac (506 days) vs. non-cardiac deaths (400 days). The presence of CHF at the time of diagnosis did not affect the survival time (P=0.854). No difference in median survival time was noted between breeds (P=0.126). Dogs with persistent atrial standstill have a median survival time of 866 days with pacemaker implantation, though a wide range of survival times was observed. There was no difference in the median survival time for dogs with cardiac-related deaths and those without. Patient breed and the presence of CHF before pacemaker implantation did not affect median survival time. Copyright © 2017 Elsevier B.V. All rights reserved.
Rodríguez-Mañero, Moisés; González-Melchor, Layla; Ballesteros, Gabriel; Raposeiras-Roubín, Sergio; García-Seara, Javier; López, Xesús Alberte Fernández; Cambeiro, Cristina González; Alcalde, Oscar; García-Bolao, Ignacio; Martínez-Sande, Luis; González-Juanatey, José Ramón
2016-01-01
Little is known about the risk of pacemaker implantation after common atrial flutter ablation in the long-term. We retrospectively reviewed the electrophysiology laboratory database at two Spanish University Hospitals from 1998 to 2012 to identify patients who had undergone successful ablation for cavotricuspid dependent atrial flutter. Cox regression analysis was used to examine the risk of pacemaker implantation. A total of 298 patients were considered eligible for inclusion. The mean age of the enrolled patients was 65.7±11. During 57.7±42.8 months, 30 patients (10.1%) underwent pacemaker implantation. In the stepwise multivariate models only heart rate at the time of the ablation (OR: 0.96; 95% CI: 0.93-0.98; p<0.0001) and intraventricular conduction disturbances in the baseline ECG (OR: 3.87; 95% CI: 1.54-9.70; p=0.004) were independents predictors of the need of pacemaker implantation. A heart rate of ≤65 bpm was identified as the optimal cut-off value to predict the need of pacemaker implantation in the follow-up (sensitivity: 79%, specificity: 74%) by ROC curve analyses. This is the first study of an association between the slow conducting common atrial flutter and subsequent risk of pacemaker implantation. In light of these findings, assessing it prior to ablation can be helpful for the risk stratification of sinus node disease or atrioventricular conduction disease requiring a pacemaker implantation in patients with persistent atrial flutter. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
van Hemel, N M; Dijkman, B; de Voogt, W G; Beukema, W P; Bosker, H A; de Cock, C C; Jordaens, L J L M; van Gelder, I C; van Gelder, L M; van Mechelen, R; Ruiter, J H; Sedney, M I; Slegers, L C
2004-01-01
Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively.
Remodeling of sinus node function after catheter ablation of right atrial flutter.
Daoud, Emile G; Weiss, Raul; Augostini, Ralph S; Kalbfleisch, Steven J; Schroeder, Jason; Polsinelli, Georgia; Hummel, John D
2002-01-01
The purpose of this study was to investigate the effect of ablation of right atrial flutter upon sinus node function in humans. This study enrolled 35 patients. Twenty-four patients (16 men and 8 women; age 68 +/- 11 years) were referred for ablation of persistent atrial flutter (duration 8 +/- 11 months). After ablation, there was abnormal sinus node function defined as a corrected sinus node recovery time (CSNRT) > or = 550 msec. The control group consisted of 11 patients who were undergoing pacemaker implantation for sinus node disease but did not have a history of atrial dysrhythmias or ablation. Within 24 hours of ablation or pacemaker implantation, baseline maximal CSNRT was measured through a permanent pacemaker by AAI pacing at six cycle lengths: 600, 550, 500, 450, 400, and 350 msec. CSNRT then was measured in the same manner at 48 hours, 14 days, and 3 months after ablation/pacemaker implantation. P wave amplitude and duration, and percent atrial sensing also were assessed at the same intervals. For patients undergoing atrial flutter ablation, there was progressive temporal recovery of CSNRT (1,204 +/- 671 msec at baseline vs 834 +/- 380 msec at 3 months; P < 0.001) and a significant increase in the percent atrial sensing and P wave amplitude at 3 months compared with baseline (P < 0.001). In control subjects, there was no change in the CSNRT, percent atrial pacing, or P wave amplitude. After ablation of persistent atrial flutter, there is temporal recovery of CSNRT and increase in spontaneous atrial activity. These findings suggest that atrial flutter induces reversible changes in sinus node function.
Subclinical atrial fibrillation and the risk of stroke.
Healey, Jeff S; Connolly, Stuart J; Gold, Michael R; Israel, Carsten W; Van Gelder, Isabelle C; Capucci, Alessandro; Lau, C P; Fain, Eric; Yang, Sean; Bailleul, Christophe; Morillo, Carlos A; Carlson, Mark; Themeles, Ellison; Kaufman, Elizabeth S; Hohnloser, Stefan H
2012-01-12
One quarter of strokes are of unknown cause, and subclinical atrial fibrillation may be a common etiologic factor. Pacemakers can detect subclinical episodes of rapid atrial rate, which correlate with electrocardiographically documented atrial fibrillation. We evaluated whether subclinical episodes of rapid atrial rate detected by implanted devices were associated with an increased risk of ischemic stroke in patients who did not have other evidence of atrial fibrillation. We enrolled 2580 patients, 65 years of age or older, with hypertension and no history of atrial fibrillation, in whom a pacemaker or defibrillator had recently been implanted. We monitored the patients for 3 months to detect subclinical atrial tachyarrhythmias (episodes of atrial rate >190 beats per minute for more than 6 minutes) and followed them for a mean of 2.5 years for the primary outcome of ischemic stroke or systemic embolism. Patients with pacemakers were randomly assigned to receive or not to receive continuous atrial overdrive pacing. By 3 months, subclinical atrial tachyarrhythmias detected by implanted devices had occurred in 261 patients (10.1%). Subclinical atrial tachyarrhythmias were associated with an increased risk of clinical atrial fibrillation (hazard ratio, 5.56; 95% confidence interval [CI], 3.78 to 8.17; P<0.001) and of ischemic stroke or systemic embolism (hazard ratio, 2.49; 95% CI, 1.28 to 4.85; P=0.007). Of 51 patients who had a primary outcome event, 11 had had subclinical atrial tachyarrhythmias detected by 3 months, and none had had clinical atrial fibrillation by 3 months. The population attributable risk of stroke or systemic embolism associated with subclinical atrial tachyarrhythmias was 13%. Subclinical atrial tachyarrhythmias remained predictive of the primary outcome after adjustment for predictors of stroke (hazard ratio, 2.50; 95% CI, 1.28 to 4.89; P=0.008). Continuous atrial overdrive pacing did not prevent atrial fibrillation. Subclinical atrial tachyarrhythmias, without clinical atrial fibrillation, occurred frequently in patients with pacemakers and were associated with a significantly increased risk of ischemic stroke or systemic embolism. (Funded by St. Jude Medical; ASSERT ClinicalTrials.gov number, NCT00256152.).
Biffi, Mauro; Bertini, Matteo; Saporito, Davide; Belotti, Giuseppina; Quartieri, Fabio; Piancastelli, Maurizio; Pucci, Angelo; Boggian, Giulio; Mazzocca, Gian Franco; Giorgi, Davide; Diotallevi, Paolo; Diemberger, Igor; Martignani, Cristian; Pancaldi, Stefano; Ziacchi, Matteo; Marcantoni, Lina; Toselli, Tiziano; Attala, Simone; Iori, Matteo; Bottoni, Nicola; Argnani, Selina; Tomasi, Corrado; Sassone, Biagio; Boriani, Giuseppe
2016-10-01
We investigated the applicability of the Ventricular Capture Control (VCC) and Atrial Capture Control (ACC) algorithms for automatic management of cardiac stimulation featured by Biotronik pacemakers in a broad, unselected population of pacemaker recipients. Ventricular Capture Control and Atrial Capture Control were programmed to work at a maximum adapted output voltage as 4.8 V in consecutive recipients of Biotronik pacemakers. Ambulatory threshold measurements were made 1 and 12 months after pacemaker implant/replacement in all possible pacing/sensing configurations, and were compared with manual measurements. Among 542 patients aged 80 (73-85) years, 382 had a pacemaker implant and 160 a pacemaker replacement. Ventricular Capture Control could work at long term in 97% of patients irrespectively of pacing indication, lead type, and lead service life, performance being superior with discordant pacing/sensing configurations. Atrial Capture Control could work in 93% of patients at 4.8 V maximum adapted voltage and at any pulse width, regardless of pacing indication, lead type, and service life. At 12-month follow-up, a ventricular threshold increase ≥1.5 V had occurred in 4.4% of patients uneventfully owing to VCC functioning. Projected pacemaker longevity at 1 month was strongly correlated with the 12-month estimate, and exceeded 13 years in >60% of patients. These algorithms for automatic management of pacing output ensure patient safety in the event of a huge increase of pacing threshold, while enabling maximization of battery longevity. Their applicability is quite broad in an unselected pacemaker population irrespectively of lead choice and service of life. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Pastori, Julio Daniel; Garro, Hugo Ariel; Baranchuk, Adrián; Chiale, Pablo Ambrosio
2012-01-01
We describe a previously unreported phenomenon of intermittent outflow right ventricular tract capture from the atrial lead of a dual-chamber pacemaker. This was more obvious at slower paced atrial rates and disappeared by decreasing the atrial pulses voltage. Electroanatomical mapping showed that the onset of activation was nearly simultaneous at the insertion site of the atrial lead and at an intermediate level of the right ventricular outflow tract. This exceptional finding might be erroneously diagnosed as due to pseudo-pseudo fusion beats. Copyright © 2012 Elsevier Inc. All rights reserved.
Zupan, Igor; Lipar, Luka; Zizek, David; Boute, Wim; Vidmar, Masa; Gabrijelcic, Tone; Rakovec, Peter; Brecelj, Ales
2006-10-01
The aim of this retrospective analysis was to investigate VDD mode survival, development of atrial tachyarrhythmias (AT), and long-term atrial sensing performance of VDD pacing systems. We implanted single-lead VDD pacemakers in patients with isolated atrioventricular block and performed a retrospective analysis of 307 patients who had their devices implanted between May 1994 and September 2001. In 39 patients (12.7%), the pacing mode had to be reprogrammed to a single-chamber ventricular pacing mode, mostly due to permanent AT. In 16 of these patients, the atrial sensing safety margin was less than 150%. The atrial sensing safety margin was insufficient, i.e. less than 100% in only seven patients. Although only 12 (3.9%) of the patients had a history of paroxysmal AT at the time of pacemaker implantation, 200 (65%) patients presented with AT during follow-up. The mean AT burden at the last follow-up was 2.5%. These data illustrate that single-lead VDD pacemakers can be applied without serious complications in a highly selected group of patients. Our main concern is the development of AT in a large part of our population. Over a 10-year period, two thirds of our patients presented with AT.
Surgical outcome of Fontan conversion and arrhythmia surgery: Need a pacemaker?
Terada, Takafumi; Sakurai, Hajime; Nonaka, Toshimichi; Sakurai, Takahisa; Sugiura, Junya; Taneichi, Tetsuyoshi; Ohtsuka, Ryohei
2014-07-01
Atrial tachyarrhythmias are frequent complications in the late period after the Fontan procedure, and important risk factors for a poor prognosis. The impact of Fontan conversion and arrhythmia surgery in failed Fontan patients has been described in many reports. We evaluated our experience with Fontan conversion procedures, concomitant arrhythmia surgery, and pacemaker implantation. We reviewed the hospital records of 25 consecutive patients who underwent a Fontan conversion procedure from January 2004 to March 2012. Twenty-four patients had arrhythmia surgery using cryoablation and radiofrequency ablation at the time of conversion. A bilateral atrial maze procedure was performed in 6 patients, right-side maze in 15, and isthmus block in 3. Three patients with a diagnosis of corrected transposition of the great arteries underwent simultaneous pacemaker implantation electively. There was no early death and one late death during a mean follow-up period of 21.2 months. Three tachyarrhythmia recurrences developed, and there were 4 occurrences of sinus bradycardia. Five of these patients required postoperative pacemaker implantation. The mid-term results of Fontan conversion and arrhythmia surgery in our institute were satisfactory. The occurrence of unexpected postoperative pacemaker requirement was high in the patients who underwent a right atrial or bilateral atrial maze procedure. Pacemaker or lead implantation is recommended for patients planned to undergo a right-side or full maze procedure. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
RUSSO, VINCENZO; DI MEO, FEDERICA; PAPA, ANDREA ANTONIO; CIOPPA, NADIA DELLA; PROIETTI, RICCARDO; RUSSO, MARIA GIOVANNA; CALABRÒ, RAFFAELE; POLITANO, LUISA
2014-01-01
P-wave dispersion is a non invasive indicator of intra-atrial conduction heterogeneity producing substrate for reentry, which is a pathophysiological mechanism of atrial fibrillation. The relationship between P-wave dispersion (PD) and atrial fibrillation (AF) in Myotonic dystrophy type 1 (DM1) patients is still unclear. Atrial Preference Pacing (APP) is an efficient algorithm to prevent paroxysmal AF in patients implanted with dual-chamber pacemaker. Aim of our study was to evaluate the possible correlation between atrial preference pacing algorithm, P-wave dispersion and AF burden in DM1 patients with normal cardiac function underwent permanent dual-chamber pacemaker implantation. We enrolled 50 patients with DM1 (age 50.3 ± 7.3; 11 F) underwent dual-chamber pacemaker implantation for various degree of atrioventricula block. The study population was randomized following 1 months stabilization period to APP algorithm features programmed OFF or ON. Patients were assessed every 3 months for the first year, and every 6 months thereafter up to 3 years. At each follow-up visit, we counted: the number of premature atrial beats, the number and the mean duration of AF episodes, AF burden and the percentage of atrial and ventricular pacing. APP ON Group showed lower number of AF episodes (117 ± 25 vs. 143 ± 37; p = 0.03) and AF burden (3059 ± 275 vs. 9010 ± 630 min; p < 0.04) than APP OFF Group. Atrial premature beats count (44903 ± 30689 vs. 13720 ± 7717 beats; p = 0.005) and Pwave dispersion values (42,1 ± 11 ms vs. 29,1 ± 4,2 ms, p = 0,003) were decreased in APP ON Group. We found a significant positive correlation between PD and AF burden (R = 0,8, p = 0.007). Atrial preference pacing algorithm, decreasing the number of atrial premature beats and the P-wave dispersion, reduces the onset and perpetuator factors of AF episodes and decreases the AF burden in DM1 patients underwent dual chamber pacemaker implantation for various degree of atrioventricular blocks and documented atrial fibrillation. PMID:25873781
Kantharia, Bharat K; Freedman, Roger A; Hoekenga, David; Tomassoni, Gery; Worley, Seth; Sorrentino, Robert; Steinhaus, David; Wolkowicz, Joel M; Syed, Zaffer A
2007-11-01
Different pacing sites and various algorithms have been utilized to prevent atrial fibrillation (AF) in pacemaker recipients. However, the optimal pacing rate settings have not yet been established. In this randomized, prospective, multicentre, single-blinded, cross over study, rate-adaptive pacing at a high base rate (BR) in patients, age 60 years or above, or a history of paroxysmal AF, who underwent dual-chamber (DDD) pacemaker implantation for standard pacing indications, was evaluated for prevention of AF. In the study cohort of 145 patients implanted with DDD pacemakers with a programmable rest rate (RR) feature, the BR/RR settings were sequentially but randomly adjusted as follows: 60 bpm/Off for the baseline quarter (initial 3 months) and then to either 'A-B-C' or 'C-B-A' settings (A = 70/65 bpm, B = 70/Off, C = 80/65 bpm) for the subsequent quarters each of 3 months duration. Data on automatic mode switch episodes, device diagnostics, and a questionnaire evaluating pacemaker awareness and palpitations were collected. Ninety-nine patients, mean age 77 +/- 10 years, who completed the study protocol and followed for 12 months did not show significant differences in the number of mode switch episodes between any settings used. The percentage of atrial pacing was lower during baseline pacing compared to settings A, B, and C (P < 0.0001). Setting C produced a higher percentage of atrial pacing than A and B (P < 0.01). Although a higher percentage of atrial pacing correlated with a lower incidence of mode switch episodes, there was no statistically significant difference in the number of mode switch episodes between settings A, B, and C. There were no significant differences in the questionnaire scores relating to pacemaker awareness or palpitation. Overdrive single-site pacing in the right atrium achieved by programming analysed settings in the present study did not reduce AF as assessed by mode switch episodes. Additionally, no change in the symptoms of arrhythmia or awareness of pacing was seen.
MacAulay, Kevin
2002-01-01
An Ibizan hound cross was referred with a 1-year history of syncope and exercise intolerance. An electrocardiogram showed bradycardia and no P waves; atrial standstill was diagnosed. A permanent artificial endocardial pacemaker was implanted. The lead dislodged and was reimplanted into the right ventricular apex. Capture was once again achieved. PMID:12395764
Kaul, Pankaj; Adluri, Krishna; Javangula, Kalyana; Baig, Wasir
2009-01-01
A 59 year old man underwent mechanical tricuspid valve replacement and removal of pacemaker generator along with 4 pacemaker leads for pacemaker endocarditis and superior vena cava obstruction after an earlier percutaneous extraction had to be abandoned, 13 years ago, due to cardiac arrest, accompanied by silent, unsuspected right atrial perforation and exteriorisation of lead. Postoperative course was complicated by tricuspid valve thrombosis and secondary pulmonary embolism requiring TPA thrombolysis which was instantly successful. A review of literature of pacemaker endocarditis and tricuspid thrombosis along with the relevant management strategies is presented. We believe this case report is unusual on account of non operative management of right atrial lead perforation following an unsuccessful attempt at percutaneous removal of right sided infected pacemaker leads and the incidental discovery of the perforated lead 13 years later at sternotomy, presentation of pacemaker endocarditis with a massive load of vegetations along the entire pacemaker lead tract in superior vena cava, right atrial endocardium, tricuspid valve and right ventricular endocardium, leading to a functional and structural SVC obstruction, requirement of an unusually large dose of warfarin postoperatively occasioned, in all probability, by antibiotic drug interactions, presentation of tricuspid prosthetic valve thrombosis uniquely as vasovagal syncope and isolated hypoxia and near instantaneous resolution of tricuspid prosthetic valve thrombosis with Alteplase thrombolysis. PMID:19239701
de Campos, Nelson Leonardo Kerdahi Leite; de Andrade, Rubens Ramos; Fellicio, Marcello Laneza; Martins, Antônio Sergio; Garzesi, André Monti; Garcia, Leonardo Rufino; Takeda, Tassya Bueno
2017-01-01
Introduction The pacemaker implantation VDD is considered simpler, faster, less expensive and causes fewer complications compared to DDD. However, the VDD pacemaker has not been widely used in many centers, perhaps for fear of dysfunction of the sinus node and the reduction of atrial sensitivity by the pacemaker during follow-up after implantation. Objective To compare patients with DDD and VDD pacemakers regarding the evolution of chronic atrial fibrillation (AF) and length of stay outside this postoperative arrhythmia. Methods It was included 158 patients with dual chamber pacemakers, 48 DDD and 110 VDD. Follow-up period: between January 1, 1999 and December 31, 2015. The mean follow-up of patients with DDD was 5.35 years and the VDD, 4.74 years. The percentage of each group (DDD and VDD) which evolved to AF during follow-up was assessed. Also, it was made an actuarial study with the respective curves indicating the time free from AF for each group. Patients were classified according to the diagnosis that led to pacemaker implantation and the degree of heart failure. Results The percentage of patients who developed AF was higher in DDD group (10.42%) than in VDD group (6.36%), but without statistical significance. Patients with DDD and VDD remained free of AF for similar period. Conclusion Considering the results, the VDD pacemaker continues to be a good option to the DDD for routine use in cases properly indicated. PMID:29211212
Campos, Nelson Leonardo Kerdahi Leite de; Andrade, Rubens Ramos de; Fellicio, Marcello Laneza; Martins, Antônio Sergio; Garzesi, André Monti; Garcia, Leonardo Rufino; Takeda, Tassya Bueno
2017-01-01
The pacemaker implantation VDD is considered simpler, faster, less expensive and causes fewer complications compared to DDD. However, the VDD pacemaker has not been widely used in many centers, perhaps for fear of dysfunction of the sinus node and the reduction of atrial sensitivity by the pacemaker during follow-up after implantation. To compare patients with DDD and VDD pacemakers regarding the evolution of chronic atrial fibrillation (AF) and length of stay outside this postoperative arrhythmia. It was included 158 patients with dual chamber pacemakers, 48 DDD and 110 VDD. Follow-up period: between January 1, 1999 and December 31, 2015. The mean follow-up of patients with DDD was 5.35 years and the VDD, 4.74 years. The percentage of each group (DDD and VDD) which evolved to AF during follow-up was assessed. Also, it was made an actuarial study with the respective curves indicating the time free from AF for each group. Patients were classified according to the diagnosis that led to pacemaker implantation and the degree of heart failure. The percentage of patients who developed AF was higher in DDD group (10.42%) than in VDD group (6.36%), but without statistical significance. Patients with DDD and VDD remained free of AF for similar period. Considering the results, the VDD pacemaker continues to be a good option to the DDD for routine use in cases properly indicated.
Lelakowski, Jacek; Majewski, Jacek; Małecka, Barbara; Bednarek, Jacek; Stypuła, Paweł; Szeglowski, Marcin
2007-01-01
During implantation of a DDD pacemaker the following difficulties may be encountered: venous anomalies (the absence of vessels of adequate calibre or difficulty in subclavian vein puncture), arrhythmias during implantation (episodes of atrial flutter/fibrillation while the atrial leads are being positioned), lack of mechanical stability of the electrode in the heart chamber and inability to achieve an acceptable pacing and sensing threshold during implantation. The purpose of the study was to analyse retrospectively the reasons for DDD pacemaker failure in patients operated on between 1993 and 2005. We reviewed retrospectively all implantation data from 1988 to 2005 to identify patients with primary failure of DDD pacemaker implantation. Further analysis included patients who had received a DDD pacemaker between 1993 and 2005, when this type of pacemaker made up between 9 and 40% of all pacemaker implantations. We implanted 7469 pacemakers, including 1958 (26.2%) dual-chamber pacemakers, in 783 patients with atrioventricular block (AVB), 392 with sick sinus syndrome (SSS), 450 with AVB +/- SSS and 333 with tachy-brady syndrome (TBS). The mean age of the patients was 65.5 +/- 17.3 years. DDD pacing was unsuccessful in 108 (1.4%) patients, including 32 with AVB, 22 with SSS, 16 with SSS +/- AVB and 38 with TBS. The mean age of these patients was 78.5 +/- 19.4 years. The reasons for failed implantation were venous anomalies in 12%, an arrhythmia episode in 27.8%, a high pacing threshold in the atrium in 17.6%, low atrial potential amplitude in 25.9% and lack of mechanical stability of the electrode in 16.7% of patients. The difficulties were encountered in elderly patients (p < 0.01), most frequently in patients with SSS and TBS (71). Between 2004 and 2005 venous anomalies and a high pacing threshold were the main causes of failure. Currently the main difficulties encountered during pacemaker implantation are venous anomalies and a high pacing threshold. Arrhythmia episodes, low atrial potential amplitude and lack of mechanical stability are of minor importance. Elderly patients with sick sinus syndrome and tachy-brady syndrome have the highest failure rate. (Cardiol J 2007; 14: 155-159).
Intermittent pacemaker dysfunction caused by digital mobile telephones.
Naegeli, B; Osswald, S; Deola, M; Burkart, F
1996-05-01
This study was designed to evaluate possible interactions between digital mobile telephones and implanted pacemakers. Electromagnetic fields may interfere with normal pacemaker function. Development of bipolar sensing leads and modern noise filtering techniques have lessened this problem. However, it remains unclear whether these features also protect from high frequency noise arising from digital cellular phones. In 39 patients with an implanted pacemaker (14 dual-chamber [DDD], 8 atrial-synchronized ventricular-inhibited [VDD(R)] and 17 ventricular-inhibited [VVI(R)] pacemakers), four mobile phones with different levels of power output (2 and 8 W) were tested in the standby, dialing and operating mode. During continuous electrocardiographic monitoring, 672 tests were performed in each mode with the phones positioned over the pulse generator, the atrial and the ventricular electrode tip. The tests were carried out at different sensitivity settings and, where possible, in the unipolar and bipolar pacing modes as well. In 7 (18%) of 39 patients, a reproducible interference was induced during 26 (3.9%) of 672 tests with the operating phones in close proximity (<10 cm) to the pacemaker. In 22 dual-chamber (14 DDD, 8 VDD) pacemakers, atrial triggering occurred in 7 (2.8%) of 248 and ventricular inhibition in 5 (2.8%) of 176 tests. In 17 VVI(R) systems, pacemaker inhibition was induced in 14 (5.6%) of 248 tests. Interference was more likely to occur at higher power output of the phone and at maximal sensitivity of the pacemakers (maximal vs. nominal sensitivity, 6% vs. 1.8% positive test results, p = 0.009). When the bipolar and unipolar pacing modes were compared in the same patients, ventricular inhibition was induced only in the unipolar mode (12.5% positive test results, p = 0.0003). Digital mobile phones in close proximity to implanted pacemakers may cause intermittent pacemaker dysfunction with inappropriate ventricular tracking and potentially dangerous pacemaker inhibition.
Bajaj, Mandeep; Cunningham, Glenn R.
2014-01-01
Pheochromocytoma should be considered in young patients who have acute cardiac decompensation, even if they have no history of hypertension. Atrioventricular node ablation and pacemaker placement should be considered for stabilizing pheochromocytoma patients with cardiogenic shock due to atrial tachyarrhythmias. A 38-year-old black woman presented with cardiogenic shock (left ventricular ejection fraction, <0.15) that did not respond to the placement of an intra-aortic balloon pump. A TandemHeart® Percutaneous Ventricular Assist Device was inserted emergently. After atrioventricular node ablation and placement of a temporary pacemaker, the TandemHeart was removed. Computed tomography of the abdomen revealed a pheochromocytoma. After placement of a permanent pacemaker, the patient underwent a right adrenalectomy. This is, to our knowledge, the first reported case of pheochromocytoma-induced atrial tachyarrhythmia that led to cardiogenic shock and cardiac arrest unresolved by the placement of 2 different ventricular assist devices, but that was completely reversed by radiofrequency ablation of the atrioventricular node and the placement of a temporary pacemaker. We present the patient's clinical, laboratory, and imaging findings, and we review the relevant literature. PMID:25593537
Apali, Zeynep; Bayata, Serdar; Yeşil, Murat; Arikan, Erdinç; Postaci, Nursen
2010-08-01
We aimed to investigate the effect of atrial pacing on left ventricular diastolic function and brain natriuretic peptide (BNP) levels in patients with DDD pacemaker. Thirty patients with complete atrio-ventricular (AV) block and DDD pacemaker were included. All patients had normal left ventricular systolic function. Echocardiographic diastolic function parameters (transmitral and tissue Doppler velocities during early (E and E') and late (A and A') filling) and NT-pro-BNP levels were evaluated prospectively during atrial sensing and pacing periods. Echocardiographic data were compared with paired sample t test and NT-pro-BNP levels were compared with Wilcoxon test. Echocardiographic E/A, E'/A', E/E' ratios were calculated as 0.72+/-0.34, 0.61+/-0.21 and 8.76+/-2.58 during atrial sensing period. Same parameters were found as 0.71+/-0.23, 0.64+/-0.16 and 8.93+/-3.16 respectively during atrial pacing period. Echocardiographic left ventricular diastolic function parameters were not significantly different during atrial pacing and atrial sensing periods. Median plasma NT-pro-BNP levels were measured as 142 pg/ml (min-max 47-563 pg/ml) and 147 pg/ml (min-max 33-1035 pg/ml) during atrial sensing and pacing periods respectively. These levels were not significantly different (p=0.86). The result of this study has shown that, atrial pacing has not any additional detrimental effect on left ventricular diastolic function parameters in paced patients with normal left ventricular systolic function.
Transvenous pacemaker electrodes placed unintentionally in the left ventricle: three cases.
Winner, S. J.; Boon, N. A.
1989-01-01
Three patients are described in whom pacemaker electrodes were unintentionally placed within the left ventricle, followed by considerable delay before the error was recognized. In two cases temporary pacemaker wires were inserted into the subclavian artery and passed along a retrograde course. One patient required urgent surgery for acute arterial obstruction on removal of the wire. In the third case, a permanent wire was inserted correctly into a vein but traversed the atrial septum, probably via a patent foramen ovale, to enter the left ventricle. Twelve lead electrocardiograms in all three patients showed paced complexes with right bundle branch block configuration. This appearance should raise suspicion that the pacemaker electrode might be in the left ventricle, in which case its position should be defined by chest radiographs (including a lateral view) and echocardiography. Images Figure 1 Figure 3 Figure 4 PMID:2780472
Spitzer, Stefan G; Wacker, Petra; Gazarek, Steffen; Malinowski, Klaus; Schibgilla, Volker
2009-12-01
PASTA (pacing of the atria in sinus node disease) is a prospective and randomized trial, assessing the effect of different atrial lead positions on the atrial fibrillation (AF) incidence in patients with sinus node disease (SND). The atrial lead position is randomized to: (a) free right atrial wall, (b) right atrial appendage (RAA), (c) coronary sinus ostium (CS-Os), or (d) dual site right atrial pacing (CS-Os + RAA). The pacemakers (Vitatron Selection 9000 or Prevent AF, Vitatron B.V., Arnhem, The Netherlands) are programmed in DDDR 70 mode and the total follow-up duration is 24 months. To describe the atrial rhythm state, pacemaker-derived data (arrhythmia counter) were assessed for AF episodes. AF was considered as evident, if the AF burden (time in AF related to follow-up interval) was >1% (i.e., 15 min/d). Follow-up data after 24 months were evaluated. The analysis evaluates 142 patients (77 male, 74.5 +/- 7.8 years). There was no statistical significant difference with respect to the occurrence of AF between the four groups after 24 months (A: 36%; B: 38%, C: 32%, D: 48%). The percentage of atrial/ventricular pacing was in A: 78/76%, in B: 84/81%, in C: 70/65%, and in D: 79/69%. These differences were not significant. The evaluation of the AF burden >1% and the total AF burden after 24 months did not show differences in the incidence of AF in patients with dual chamber pacemaker therapy for SND. We were not able to demonstrate a significant influence of right atrial lead position on the incidence of AF recurrence.
Selective interference with pacemaker activity by electrical dental devices.
Miller, C S; Leonelli, F M; Latham, E
1998-01-01
We sought to determine whether electromagnetic interference with cardiac pacemakers occurs during the operation of contemporary electrical dental equipment. Fourteen electrical dental devices were tested in vitro for their ability to interfere with the function of two Medtronics cardiac pacemakers (one a dual-chamber, bipolar Thera 7942 pacemaker, the other a single-chamber, unipolar Minix 8340 pacemaker). Atrial and ventricular pacemaker output and electrocardiographic activity were monitored by means of telemetry with the use of a Medtronics 9760/90 programmer. Atrial and ventricular pacing were inhibited by electromagnetic interference produced by the electrosurgical unit up to a distance of 10 cm, by the ultrasonic bath cleaner up to 30 cm, and by the magnetorestrictive ultrasonic scalers up to 37.5 cm. In contrast, operation of the amalgamator, electric pulp tester, composite curing light, dental handpieces, electric toothbrush, microwave oven, dental chair and light, ENAC ultrasonic instrument, radiography unit, and sonic scaler did not alter pacing rate or rhythm. These results suggest that certain electrosurgical and ultrasonic instruments may produce deleterious effects in medically fragile patients with cardiac pacemakers.
Ziacchi, Matteo; Palmisano, Pietro; Biffi, Mauro; Ricci, Renato P; Landolina, Maurizio; Zoni-Berisso, Massimo; Occhetta, Eraldo; Maglia, Giampiero; Botto, Gianluca; Padeletti, Luigi; Boriani, Giuseppe
2018-04-01
: Modern pacemakers have an increasing number of programable parameters and specific algorithms designed to optimize pacing therapy in relation to the individual characteristics of patients. When choosing the most appropriate pacemaker type and programing, the following variables must be taken into account: the type of bradyarrhythmia at the time of pacemaker implantation; the cardiac chamber requiring pacing, and the percentage of pacing actually needed to correct the rhythm disorder; the possible association of multiple rhythm disturbances and conduction diseases; the evolution of conduction disorders during follow-up. The goals of device programing are to preserve or restore the heart rate response to metabolic and hemodynamic demands; to maintain physiological conduction; to maximize device longevity; to detect, prevent, and treat atrial arrhythmia. In patients with sinus node disease, the optimal pacing mode is DDDR. Based on all the available evidence, in this setting, we consider appropriate the activation of the following algorithms: rate responsive function in patients with chronotropic incompetence; algorithms to maximize intrinsic atrioventricular conduction in the absence of atrioventricular blocks; mode-switch algorithms; algorithms for autoadaptive management of the atrial pacing output; algorithms for the prevention and treatment of atrial tachyarrhythmias in the subgroup of patients with atrial tachyarrhythmias/atrial fibrillation. The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients' clinical features.
The effect of hyperkalaemia on cardiac rhythm devices.
Barold, S Serge; Herweg, Bengt
2014-04-01
In patients with pacemakers, hyperkalaemia causes three important abnormalities that usually become manifest when the K level exceeds 7 mEq/L: (i) widening of the paced QRS complex from delayed intraventricular conduction velocity, (ii) Increased atrial and ventricular pacing thresholds that may cause failure to capture. In this respect, the atria are more susceptible to loss of capture than the ventricles, and (iii) Increased latency (usually with ventricular pacing) manifested by a greater delay of the interval from the pacemaker stimulus to the onset of depolarization. First-degree ventricular pacemaker exit block may progress to second-degree Wenckebach (type I) exit block characterized by gradual prolongation of the interval from the pacemaker stimulus to the onset of the paced QRS complex ultimately resulting in an ineffectual stimulus. The disturbance may then progress to 2 : 1, 3 : 1 pacemaker exit block, etc., and eventually to complete exit block with total lack of capture. Ventricular undersensing is uncommonly observed because of frequent antibradycardia pacing. During managed ventricular pacing, hyperkalaemia-induced marked first-degree atrioventricular block may induce a pacemaker syndrome. With implantable cardioverter-defibrillators (ICDs) oversensing of the paced or spontaneous T-wave may occur. The latter may cause inappropriate shocks. A raised impedance from the right ventricular coil to the superior vena cava coil may become an important sign of hyperkalaemia in the asymptomatic or the minimally symptomatic ICD patient.
Wang, Xule; Huang, Congxin; Zhao, Qingyan; Huang, He; Tang, Yanhong; Dai, Zixuan; Wang, Xiaozhan; Guo, Zongwen; Xiao, Jinping
2015-04-01
The aim of the present study was to explore the effect of renal sympathetic denervation (RSD) on the progression of paroxysmal atrial fibrillation (AF) in canines with long-term intermittent atrial pacing. Nineteen beagles were randomly divided into sham-operated group (six dogs), control group (six dogs), and RSD group (seven dogs). Sham-operated group were implanted with pacemakers without pacing; control group were implanted with pacemakers with long-term intermittent atrial pacing; and RSD group underwent catheter-based RSD bilaterally and were simultaneously implanted with pacemakers. Atrial pacing was maintained for 8 h a day and a total of 12 weeks in the control group and RSD group. Echocardiography showed that the left atrial structure and function were significantly improved in the RSD group compared with the control group (P < 0.05). Compared with the control group, the RSD group had fewer incidences of AF and a shorter duration of AF (P < 0.05) after long-term intermittent atrial pacing. In addition to increased atrial effective refractory period (AERP) and AF cycle length, AERP dispersion and P-wave duration and dispersion were significantly decreased in the RSD group compared with the control group (P < 0.05). Atrial morphological evaluation suggested that fibrosis and ultrastructural changes induced by long-term intermittent atrial pacing were markedly suppressed in the RSD dogs compared with controls (P < 0.05). Immunohistochemistry results showed that connexin 43 distribution in RSD mid-myocardial was significantly fewer heterogeneous than that in control mid-myocardial (P < 0.05). Renal denervation inhibits the progression of paroxysmal AF, which might be related to the suppression of atrial electrophysiology and structural heterogeneity. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Hanon, Sam; Shapiro, Michael; Schweitzer, Paul
2004-07-01
The following article presents an unusual case of atrial tachycardia, initially misdiagnosed due to a lack of clear P waves. The diagnosis was eventually confirmed using the atrial electrogram from the patient's pacemaker.
Silent Atrial Fibrillation in Elderly Pacemaker Users: A Randomized Trial Using Home Monitoring.
Lima, Ceb; Martinelli, M; Peixoto, G L; Siqueira, S F; Wajngarten, Maurício; Silva, Rodrigo Tavares; Costa, Roberto; Filho, Roberto; Ramires, José Antônio Franchini
2016-05-01
Pacemaker with remote monitoring (PRM) may be useful for silent atrial fibrillation (AF) detection. The aims of this study were to evaluate the incidence of silent AF, the role of PRM, and to determine predictors of silent AF occurrence. Three hundred elderly patients with permanent pacemaker (PPM) were randomly assigned to the remote group (RG) or control group (CG). All patients received PPM with remote monitoring capabilities. Primary end point was AF occurrence rate and the secondary end points were time to AF detection and number of days with AF. During the average follow-up of 15.7±7.7 months, AF episodes were detected in 21.6% (RG = 24% vs CG = 19.3%, P = 0.36]. There was no difference in the time to detect the first AF episode. However, the median time to detect AF recurrence in the RG was lower than that in the CG (54 days vs 100 days, P = 0.004). The average number of days with AF was 16.0 and 51.2 in the RG and CG, respectively (P = 0.028). Predictors of silent AF were left atrial diameter (odds ratio [OR] 1.2; 95% CI = 1.1-1.3; P < 0.001) and diastolic dysfunction (OR 4.8; 95% CI = 1.6-14.0; P = 0.005). The incidence of silent AF is high in elderly patients with pacemaker; left atrial diameter and diastolic dysfunction were predictors of its occurrence. AF monitoring by means of pacemaker is a valuable tool for silent AF detection and continuous remote monitoring allows early AF recurrence detection and reduces the number of days with AF. © 2015 Wiley Periodicals, Inc.
den Dulk, K; Dijkman, B; Pieterse, M; Wellens, H
1994-11-01
Mode switching algorithms have been developed to avoid tracking of atrial fibrillation (AF) or flutter (AFL) during DDD(R) pacing. Upon recognition of AF or AFL, the mode is switched to a nontracking, sensor driven mode. The Vitatron Diamond model 800 pacemaker does this on a beat-to-beat basis. Atrial events occurring within a "physiological range" (+/- 15 beats/min) calculated from a running average of the atrial rate are tracked. When atrial events are not tracked the escape interval is either determined by the sensor(s) or by a fallback algorithm thereby preventing large increases in V-V interval during mode switching. Loss of atrioventricular (AV) synchrony by atrial premature beats and after an episode of AF or AFL is prevented by atrial synchronization pulses (ASP), which are delivered after a safe interval (timed out from the sensed premature atrial event) has expired and before delivery of the next ventricular stimulus. We implanted 26 such devices in 18 men and 8 women with symptomatic second- or third-degree AV block and paroxysmal AF or AFL. Their ages ranged from 18-84 years (mean 60), and the follow-up ranged from 2-13 months (mean 8). During pacemaker check-up, exercise testing or 24-hour Holter monitoring one or more episodes of mode switching was documented in 8 patients. In these 8 patients a smooth transition (ventricular rate) from sinus rhythm to AF or AFL was documented on one or more occasions, without inappropriate increase in ventricular rate in the DDDR mode. None of the patients complained of palpitations.(ABSTRACT TRUNCATED AT 250 WORDS)
Rate-dependent Loss of Capture during Ventricular Pacing.
Wang, Jingfeng; Chen, Haiyan; Su, Yangang; Ge, Junbo
2015-01-01
A 63-year-old patient who had undergone atrial septal defect surgical repair received implantation of a single chamber VVI pacemaker for long RR intervals during atrial fibrillation. One week later, an intermittent loss of capture and sensing failure was detected at a pacing rate of 70 beats/min. However, a successful capture was observed during rapid pacing. Consequently, the pacing rate was temporarily adjusted to 90 beats/min. At the 3-month follow-up, the pacemaker was shown to be functioning properly independent of the pacing rate. An echocardiogram showed that the increased pacing rates were accompanied by a reduction in the right ventricular outflow tract dimension. The pacemaker was then permanently programmed at a lower rate of 60 beats/min.
Rescuing cardiac automaticity in L-type Cav1.3 channelopathies and beyond.
Mesirca, Pietro; Bidaud, Isabelle; Mangoni, Matteo E
2016-10-15
Pacemaker activity of the sino-atrial node generates the heart rate. Disease of the sinus node and impairment of atrioventricular conduction induce an excessively low ventricular rate (bradycardia), which cannot meet the needs of the organism. Bradycardia accounts for about half of the total workload of clinical cardiologists. The 'sick sinus' syndrome (SSS) is characterized by sinus bradycardia and periods of intermittent atrial fibrillation. Several genetic or acquired risk factors or pathologies can lead to SSS. Implantation of an electronic pacemaker constitutes the only available therapy for SSS. The incidence of SSS is forecast to double over the next 50 years, with ageing of the general population thus urging the development of complementary or alternative therapeutic strategies. In recent years an increasing number of mutations affecting ion channels involved in sino-atrial automaticity have been reported to underlie inheritable SSS. L-type Ca v 1.3 channels play a major role in the generation and regulation of sino-atrial pacemaker activity and atrioventricular conduction. Mutation in the CACNA1D gene encoding Ca v 1.3 channels induces loss-of-function in channel activity and underlies the sino-atrial node dysfunction and deafness syndrome (SANDD). Mice lacking Ca v 1.3 channels (Ca v 1.3 -/- ) fairly recapitulate SSS and constitute a precious model to test new therapeutic approaches to handle this disease. Work in our laboratory shows that targeting G protein-gated K + (I KACh ) channels effectively rescues SSS of Ca v 1.3 -/- mice. This new concept of 'compensatory' ion channel targeting shines new light on the principles underlying the pacemaker mechanism and may open the way to new therapies for SSS. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Implantable cardiac arrhythmia devices--part I: pacemakers.
Kusumoto, Fred M; Goldschlager, Nora
2006-05-01
Implantable cardiac devices have become firmly entrenched as important therapeutic tools for a variety of cardiac conditions. The first part of this two-part review will discuss the contemporary use and follow-up of pacemakers, while the second part will address the use of implantable cardioverter defibrillators and implantable loop recorders. Pacemakers are the only available treatment for symptomatic bradycardia not due to reversible causes. Large randomized studies have demonstrated a small but statistically significant reduction in atrial fibrillation associated with pacing modes that maintain atrioventricular synchrony. In contrast, pacing mode appears to have a less dramatic effect in patients with atrioventricular block. Cardiac resynchronization with specialized left ventricular leads has been shown to reduce symptoms and improve survival in patients with symptomatic heart failure, systolic dysfunction, and widened QRS complexes. For all patients, careful follow-up is necessary to ensure optimal therapeutic benefit of pacing systems.
Rates of Atrial Fibrillation in Black Versus White Patients With Pacemakers.
Kamel, Hooman; Kleindorfer, Dawn O; Bhave, Prashant D; Cushman, Mary; Levitan, Emily B; Howard, George; Soliman, Elsayed Z
2016-02-12
Black US residents experience higher rates of ischemic stroke than white residents but have lower rates of clinically apparent atrial fibrillation (AF), a strong risk factor for stroke. It is unclear whether black persons truly have less AF or simply more undiagnosed AF. We obtained administrative claims data from state health agencies regarding all emergency department visits and hospitalizations in California, Florida, and New York. We identified a cohort of patients with pacemakers, the regular interrogation of which reduces the likelihood of undiagnosed AF. We compared rates of documented AF or atrial flutter at follow-up visits using Kaplan-Meier survival statistics and Cox proportional hazards models adjusted for demographic characteristics and vascular risk factors. We identified 10 393 black and 91 380 white patients without documented AF or atrial flutter before or at the index visit for pacemaker implantation. During 3.7 (±1.8) years of follow-up, black patients had a significantly lower rate of AF (21.4%; 95% CI 19.8-23.2) than white patients (25.5%; 95% CI 24.9-26.0). After adjustment for demographic characteristics and comorbidities, black patients had a lower hazard of AF (hazard ratio 0.91; 95% CI 0.86-0.96), a higher hazard of atrial flutter (hazard ratio 1.29; 95% CI 1.11-1.49), and a lower hazard of the composite of AF or atrial flutter (hazard ratio 0.94; 95% CI 0.88-99). In a population-based sample of patients with pacemakers, black patients had a lower rate of AF compared with white patients. These findings indicate that the persistent racial disparities in rates of ischemic stroke are likely to be related to factors other than undiagnosed AF. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Ramdjan, Tanwier T T K; van der Does, Lisette J M E; Knops, Paul; Res, Jan C J; de Groot, Natasja M S
2014-11-17
The incidence of sick sinus syndrome will increase due to population ageing. Consequently, this will result in an increase in the number of pacemaker implantations. The atrial lead is usually implanted in the right atrial appendage, but this position may be ineffective for prevention of atrial fibrillation. It has been suggested that pacing distally in the coronary sinus might be more successful in preventing atrial fibrillation episodes. The aim of this trial is to study the efficacy of distal coronary sinus versus right atrial appendage pacing in preventing atrial fibrillation episodes in patients with sick sinus syndrome. This study is designed as a multicenter, randomized controlled trial. Patients with sick sinus syndrome and at least one atrial fibrillation episode of 30 seconds or more in the six months before recruitment will be eligible for participation in this study.All participants will be randomized between pacing distally in the coronary sinus and right atrial appendage. Randomization is stratified for all participating centers. Conventional dual-chamber pacemakers with advanced home monitoring functionality will be implanted. The ventricular lead will be implanted in the right ventricular apex. The first three months of the 36-month follow-up period are considered as run-in time. During the pre-randomization visit and follow-up, an interview, electrocardiogram and pacemaker assessment will be performed, prescribed antiarrhythmic medication will be reviewed and patients will be asked to complete an SF-36 questionnaire. An echocardiographic examination will be conducted in the pre-randomization phase and at the end of each follow-up year. Home monitoring will be used to send daily reports in case of atrial fibrillation episodes. This randomized controlled trial is the first in which home monitoring will be used to compare atrial fibrillation recurrences between pacing in the distal coronary sinus or right atrial appendage. Home monitoring gives the opportunity to accurately detect atrial fibrillation episodes and to study characteristics of atrial fibrillation episodes. Should distal coronary sinus pacing significantly diminish atrial fibrillation recurrences, this study will redefine the preferential location of an atrial lead for preventive pacing. Current Controlled Trials ISRCTN65911661, registered on 8 July 2013.
Yedlapati, Neeraja; Fisher, John D
2014-09-01
We aimed to determine the practical value of pacemaker diagnostics for atrial fibrillation (AF) in an unselected general pacemaker practice, specifically workflow and initiation of anticoagulation or antiarrhythmic drug (AAD) therapy. We prospectively followed consecutive pacemaker interrogations over a period of 1 year to identify patients with AF (burden from 1% to 99%). We contacted referring physicians with AF details, and then determined whether the information resulted in therapeutic changes. Of the 1,100 pacemakers interrogated, 728 were dual chamber (DDDs) with AF diagnostic capability. AF was recorded in 73 (10%) but seven had limited information, leaving 66 patients; of these, 42 (63%) patients were already anticoagulated and in five (7%) patients, anticoagulation had been stopped because of complications. Initial diagnosis of AF was made by the pacemaker in 17 patients (26% of 66; 2% of 728); four (6% of 66) patients were newly initiated on anticoagulation. Of the 66 patients, 17 patients were already on AADs; 49 (74%) had satisfactory rate control or had other issues; only two (3% of 66; 0.3% of 728) received new AADs. Of 728 patients with DDD pacemakers, only 17 were newly discovered to have AF, and six (0.8%) had changes in medications based on the pacemaker data. Adding pacemaker-derived data to existing clinical information had little therapeutic impact, due to a combination of cumbersome workflow, and because AF was usually known to practitioners. Developments in automated monitoring systems may provide more accessible and therapeutically useful information. ©2014 Wiley Periodicals, Inc.
A fully implantable pacemaker for the mouse: from battery to wireless power.
Laughner, Jacob I; Marrus, Scott B; Zellmer, Erik R; Weinheimer, Carla J; MacEwan, Matthew R; Cui, Sophia X; Nerbonne, Jeanne M; Efimov, Igor R
2013-01-01
Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice.
van Hemel, N.M.; Dijkman, B.; de Voogt, W.G.; Beukema, W.P.; Bosker, H.A.; de Cock, C.C.; Jordaens, L.J.L.M.; van Gelder, I.C.; van Gelder, L.M.; van Mechelen, R.; Ruiter, J.H.; Sedney, M.I.; Slegers, L.C.
2004-01-01
Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively. PMID:25696255
Risk Factors For Bradycardia Requiring Pacemaker Implantation In Patients With Atrial Fibrillation
Barrett, Tyler W.; Abraham, Robert L.; Jenkins, Cathy A.; Russ, Stephan; Storrow, Alan B.; Darbar, Dawood
2012-01-01
Symptomatic bradycardia may complicate atrial fibrillation (AF) and necessitate a permanent pacemaker. Identifying patients at increased risk for symptomatic bradycardia may reduce associated morbidities and healthcare costs. We investigated predictors for developing bradycardia requiring a permanent pacemaker among AF patients. We reviewed records of all patients treated for AF/flutter in an academic hospital’s emergency department from 8/1/2005 to 8/30/2008. We determined survival and presence of a pacemaker as of 11/1/2011. Cases were defined as patients with pacemakers placed for bradycardia after their AF diagnoses. Patients without a pacemaker who were followed at our hospital comprised the controls. We identified a priori variables for the logistic regression analysis. We fit a post-hoc model adjusting for AF type and atrioventricular nodal blocker (AVN) use. Of the 362 patients in our cohort, 119 cases had permanent pacemakers implanted for bradycardia subsequent to AF diagnosis and 243 controls were alive without a pacemaker. Median and interquartile range follow-up time was 4.5 (3.8 – 5.4) years. Odds ratios and 95% confidence intervals were determined for age at time of AF diagnosis (1.02 [1, 1.04]), female (1.58 [0.95, 2.63]), prior heart failure (2.72 [1.47, 5.01]), and African-American (0.33 [0.12, 0.94]). Post-hoc model identified permanent AF (2.99 [1.61, 5.57]) and AVN use (1.43 [0.85, 2.4]). In conclusion, among AF patients, heart failure and permanent AF each nearly triple the odds of developing bradycardia requiring a permanent pacemaker; while not statistically significant, our results suggest that women are more likely and African-Americans less likely to develop bradycardia requiring pacemaker implantation. PMID:22840846
Essebag, Vidal; Reynolds, Matthew R.; Hadjis, Tom; Lemery, Robert; Olshansky, Brian; Buxton, Alfred E.; Josephson, Mark E.; Zimetbaum, Peter
2008-01-01
Background Amiodarone use was associated with an increased need for pacemaker insertion in a retrospective study of patients with atrial fibrillation (AF) and prior myocardial infarction. The aims of this study were to determine prospectively whether amiodarone increases the need for pacemakers in a general population of patients with AF and whether this effect is modified by sex. Methods The study included 1005 patients with new-onset AF who were enrolled in the Fibrillation Registry Assessing Costs, Therapies, Adverse events, and Lifestyle (FRACTAL). Multivariable Cox regression models, including time-dependent covariates accounting for medication exposure, were used to evaluate the risk of pacemaker insertion associated with amiodarone use. Results Amiodarone use was associated with an increased risk of pacemaker insertion (hazard ratio [HR], 2.01; 95% confidence interval [CI], 1.08–3.76) after adjustment for age, sex, atrial flutter, coronary artery disease, heart failure, and hypertension. The effect of amiodarone use was modified by sex, with a significant risk in women but not in men (HR, 4.69; 95% CI, 1.99–11.05 vs HR, 1.05; 95% CI, 0.42–2.58 [P = .02]). This interaction remained significant after adjustment for weight, body mass index, weight-adjusted amiodarone dose, and use of other antiarrhythmic or rate control drugs. Conclusion The risk of bradyarrhythmia requiring pacemaker insertion associated with amiodarone use for AF is significantly greater in women than in men, independent of weight or body mass index. PMID:17698688
Najib, Mohammad Q.; Vittala, Satya S.; Challa, Suresh; Raizada, Amol; Tondato, Fernando J.; Lee, Howard R.; Chaliki, Hari P.
2013-01-01
Patients with permanent pacemaker or automatic implantable cardioverter-defibrillator (AICD) leads have an increased prevalence of tricuspid regurgitation. However, the roles of cardiac rhythm and lead-placement duration in the development of severe tricuspid regurgitation are unclear. We reviewed echocardiographic data on 26 consecutive patients who had severe tricuspid regurgitation after permanent pacemaker or AICD placement; before treatment, they had no organic tricuspid valve disease, pulmonary hypertension, left ventricular dysfunction, or severe tricuspid regurgitation. We compared the results to those of 26 control subjects who had these same devices but no more than mild tricuspid regurgitation. The patients and control subjects were similar in age (mean, 81 ±6 vs 81 ±8 yr; P = 0.83), sex (male, 42% vs 46%; P = 0.78), and left ventricular ejection fraction (0.60 ±0.06 vs 0.58 ± 0.05; P = 0.4). The patients had a higher prevalence of atrial fibrillation (92% vs 65%; P=0.01) and longer median duration of pacemaker or AICD lead placement (49.5 vs 5 mo; P < 0.001). After adjusting for age, sex, and right ventricular systolic pressure by multivariate logistic regression analysis, we found that atrial fibrillation (odds ratio=6.4; P = 0.03) and duration of lead placement (odds ratio=1.5/yr; P = 0.001) were independently associated with severe tricuspid regurgitation. Out study shows that atrial fibrillation and longer durations of lead placement might increase the risk of severe tricuspid regurgitation in patients with permanent pacemakers or AICDs. PMID:24391312
Kinetics of atrial repolarization alternans in a free-behaving ovine model.
Jousset, Florian; Tenkorang, Joanna; Vesin, Jean-Marc; Pascale, Patrizio; Ruchat, Patrick; Rollin, Anne Garderes; Fromer, Martin; Narayan, Sanjiv M; Pruvot, Etienne
2012-09-01
Kinetics of Atrial Repolarization Alternans. Repolarization alternans (Re-ALT), a beat-to-beat alternation in action potential repolarization, promotes dispersion of repolarization, wavebreaks, and reentry. Recently, Re-ALT has been shown to play an important role in the transition from rapid pacing to atrial fibrillation (AF) in humans. The detailed kinetics of atrial Re-ALT, however, has not been reported so far. We developed a chronic free-behaving ovine pacing model to study the kinetics of atrial Re-ALT as a function of pacing rate. Thirteen sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms and delivery of rapid pacing protocols. Beat-to-beat differences in the atrial T-wave apex amplitude as a measure of Re-ALT and activation time were analyzed at incremental pacing rates until the effective refractory period (ERP) defined as stable 2:1 capture. Atrial Re-ALT appeared intermittently but without periodicity, and increased in amplitude as a function of pacing rate until ERP. Intermittent 2:1 atrial capture was observed at pacing cycle lengths 40 ms above ERP, and increased in duration as a function of pacing rate. Episodes of rapid pacing-induced AF were rare, and were preceded by Re-ALT or complex oscillations of atrial repolarization, but without intermittent capture. We show in vivo that atrial Re-ALT developed and increased in magnitude with rate until stable 2:1 capture. In rare instances where capture failure did not occur, Re-ALT and complex oscillations of repolarization surged and preceded AF initiation. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1003-1012, September 2012). © 2012 Wiley Periodicals, Inc.
Morris, Gwilym M; D'Souza, Alicia; Dobrzynski, Halina; Lei, Ming; Choudhury, Moinuddin; Billeter, Rudi; Kryukova, Yelena; Robinson, Richard B; Kingston, Paul A; Boyett, Mark R
2013-10-01
Although the right atrium (RA contains subsidiary atrial pacemaker (SAP) tissue that can take over from the sinoatrial node (SAN) in sick sinus syndrome (SSS), SAP tissue is bradycardic. Little is known about SAP tissue and one aim of the study was to characterize ion channel expression to obtain insight into SAP pacemaker mechanisms. A second aim was to determine whether HCN over-expression (a 'biopacemaker'-like strategy) can accelerate the pacemaker rate producing a pacemaker that is similar in nature to the SAN. SAP tissue was isolated from the rat and the leading pacemaker site was characterized. Cell size at the leading pacemaker site in the SAP was smaller than in the RA and comparable to that in the SAN. mRNA levels showed the SAP to be similar to, but distinct from, the SAN. For example, in the SAN and SAP, expression of Tbx3 and HCN1 was higher and Nav1.5 and Cx43 lower than in the RA. Organ-cultured SAP tissue beat spontaneously, but at a slower rate than the SAN. Adenovirus-mediated gene transfer of HCN2 and the chimeric protein HCN212 significantly increased the pacemaker rate of the SAP close to that of the native SAN, but HCN4 was ineffective. SAP tissue near the inferior vena cava is bradycardic, but shares characteristics with the SAN. Pacing can be accelerated by the over-expression of HCN2 or HCN212. This provides proof of concept for the use of SAP tissue as a substrate for biopacemaking in the treatment of SSS.
A Fully Implantable Pacemaker for the Mouse: From Battery to Wireless Power
Zellmer, Erik R.; Weinheimer, Carla J.; MacEwan, Matthew R.; Cui, Sophia X.; Nerbonne, Jeanne M.; Efimov, Igor R.
2013-01-01
Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice. PMID:24194832
Pacemaker implantation after catheter ablation for atrial fibrillation.
Deshmukh, Abhishek J; Yao, Xiaoxi; Schilz, Stephanie; Van Houten, Holly; Sangaralingham, Lindsey R; Asirvatham, Samuel J; Friedman, Paul A; Packer, Douglas L; Noseworthy, Peter A
2016-01-01
Sinus node dysfunction requiring pacemaker implantation is commonly associated with atrial fibrillation (AF), but may not be clinically apparent until restoration of sinus rhythm with ablation or cardioversion. We sought to determine frequency, time course, and predictors for pacemaker implantation after catheter ablation, and to compare the overall rates to a matched cardioversion cohort. We conducted a retrospective analysis using a large US commercial insurance database and identified 12,158 AF patients who underwent catheter ablation between January 1, 2005 and December 31, 2012. Over an average of 2.4 years of follow-up, 5.6 % of the patients underwent pacemaker implantation. Using the Cox proportional hazards models, we found that risk of risks of pacemaker implantation was associated with older age (50-64 and ≥65 versus <50 years), female gender, higher CHADS2 score (≥2 and 1 versus 0), higher Charlson index (≥2 versus 0-1), certain baseline comorbidities (conduction disorder, coronary atherosclerosis, and congestive heart failure), and the year of ablation. There was no significant difference in the risk of pacemaker implantation between ablation patients and propensity score (PS)-matched cardioversion groups (3.5 versus. 4.1 % at 1 year and 8.8 versus 8.3 % at 5 years). Overall, pacemaker implantation occurs in about 1/28 patients within 1 year of catheter ablation. The overall implantation rate decreased between 2005 and 2012. Furthermore, the risk after ablation is similar to cardioversion, suggesting that patients require pacing due to a common underlying electrophysiologic substrate, rather than the ablation itself.
Ogino, Yutaka; Ishikawa, Toshiyuki; Ishigami, Tomoaki; Matsumoto, Katsumi; Hosoda, Junya; Iguchi, Kouhei; Matsushita, Hirooki; Taguchi, Yuka; Horiguchi, Yoriko; Kimura, Kazuo
2017-05-25
The characteristics and prognosis of implanted pacemaker-identified new-onset atrial fibrillation (AF) in Japanese people has not been well evaluated.Methods and Results:A total of 395 consecutive patients with newly implanted pacemakers were retrospectively analyzed between January 2010 and December 2015 at Yokohama City University Hospital. Patients with a prior history of AF, VVI mode pacemaker, congenital heart disease, severe valvular heart disease, and cardiovascular surgery before pacemaker implantation were excluded. Among the remaining patients, 44 (21.3%) developed new AF during follow-up (mean follow-up, 1,115±651 days; range, 9-2,176 days). Patients with new-onset AF had a significantly higher CHADS 2 score (2.09±1.27 vs. 1.31±1.08, P<0.001) and CHA 2 DS 2 -VASc score (3.00±1.39 vs. 2.26±1.19, P<0.001) compared with those without new-onset AF. On Cox regression analysis only age at implantation was significantly correlated with new-onset AF. Interestingly, the incidence of hospitalization due to heart failure was significantly higher in the new-onset AF than in the without new-onset AF group. A total of 21.3% of pacemaker-implanted patients with high CHADS 2 and CHA 2 DS 2 -VASc scores developed new-onset AF during a mean follow-up of 3.1 years; and pacemaker-identified AF was associated with an increased risk of worsening heart failure.
Do prehospital discharge pacemaker checks provide any additional clinical benefit?
Wheelan, Kevin R; Legge, Darlene M; Sakowski, Brent C; Bruce, Susan S; Roberts, David C; Johnston, L Murphy; Moore, B Jane; Beveridge, Thomas P; Wells, Peter J; Vallabahn, Ravi; Donsky, Michael S; Franklin, Jay O
2005-08-01
We performed a retrospective analysis of 250 records of consecutive, newly implanted, pacemaker patients from a single center to determine the rate of postimplant complications and observations discovered before and during the prehospital discharge evaluation. No observations occurred in 246 of 250 patients (98.4%) (1-sided 95% confidence interval 96.4%). Of the 250 patients, 4 had observations that were discovered at the prehospital discharge check and required reprogramming to increase the sensitivity safety margin (3 atrial and 1 ventricular). We documented only 1 complication that was discovered before the predischarge evaluation through telemetry and resulted in an atrial lead revision.
Lau, Chu-Pak; Tachapong, Ngarmukos; Wang, Chun-Chieh; Wang, Jing-Feng; Abe, Haruhiko; Kong, Chi-Woon; Liew, Reginald; Shin, Dong-Gu; Padeletti, Luigi; Kim, You-Ho; Omar, Razali; Jirarojanakorn, Kreingkrai; Kim, Yoon-Nyun; Chen, Mien-Cheng; Sriratanasathavorn, Charn; Munawar, Muhammad; Kam, Ruth; Chen, Jan-Yow; Cho, Yong-Keun; Li, Yi-Gang; Wu, Shu-Lin; Bailleul, Christophe; Tse, Hung-Fat
2013-08-13
Atrial-based pacing is associated with lower risk of atrial fibrillation (AF) in sick sinus syndrome compared with ventricular pacing; nevertheless, the impact of site and rate of atrial pacing on progression of AF remains unclear. We evaluated whether long-term atrial pacing at the right atrial (RA) appendage versus the low RA septum with (ON) or without (OFF) a continuous atrial overdrive pacing algorithm can prevent the development of persistent AF. We randomized 385 patients with paroxysmal AF and sick sinus syndrome in whom a pacemaker was indicated to pacing at RA appendage ON (n=98), RA appendage OFF (n=99), RA septum ON (n=92), or RA septum OFF (n=96). The primary outcome was the occurrence of persistent AF (AF documented at least 7 days apart or need for cardioversion). Demographic data were homogeneous across both pacing site (RA appendage/RA septum) and atrial overdrive pacing (ON/OFF). After a mean follow-up of 3.1 years, persistent AF occurred in 99 patients (25.8%; annual rate of persistent AF, 8.3%). Alternative site pacing at the RA septum versus conventional RA appendage (hazard ratio=1.18; 95% confidence interval, 0.79-1.75; P=0.65) or continuous atrial overdrive pacing ON versus OFF (hazard ratio=1.17; 95% confidence interval, 0.79-1.74; P=0.69) did not prevent the development of persistent AF. In patients with paroxysmal AF and sick sinus syndrome requiring pacemaker implantation, an alternative atrial pacing site at the RA septum or continuous atrial overdrive pacing did not prevent the development of persistent AF. URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00419640.
Poller, Wolfram C; Dreger, Henryk; Schwerg, Marius; Melzer, Christoph
2015-01-01
Optimization of the AV-interval (AVI) in DDD pacemakers improves cardiac hemodynamics and reduces pacemaker syndromes. Manual optimization is typically not performed in clinical routine. In the present study we analyze the prevalence of E/A wave fusion and A wave truncation under resting conditions in 160 patients with complete AV block (AVB) under the pre-programmed AVI. We manually optimized sub-optimal AVI. We analyzed 160 pacemaker patients with complete AVB, both in sinus rhythm (AV-sense; n = 129) and under atrial pacing (AV-pace; n = 31). Using Doppler analyses of the transmitral inflow we classified the nominal AVI as: a) normal, b) too long (E/A wave fusion) or c) too short (A wave truncation). In patients with a sub-optimal AVI, we performed manual optimization according to the recommendations of the American Society of Echocardiography. All AVB patients with atrial pacing exhibited a normal transmitral inflow under the nominal AV-pace intervals (100%). In contrast, 25 AVB patients in sinus rhythm showed E/A wave fusion under the pre-programmed AV-sense intervals (19.4%; 95% confidence interval (CI): 12.6-26.2%). A wave truncations were not observed in any patient. All patients with a complete E/A wave fusion achieved a normal transmitral inflow after AV-sense interval reduction (mean optimized AVI: 79.4 ± 13.6 ms). Given the rate of 19.4% (CI 12.6-26.2%) of patients with a too long nominal AV-sense interval, automatic algorithms may prove useful in improving cardiac hemodynamics, especially in the subgroup of atrially triggered pacemaker patients with AV node diseases.
Baranchuk, Adrian; Healey, Jeff S; Thorpe, Kevin E; Morillo, Carlos A; Nair, Girish; Crystal, Eugene; Kerr, Charles R; Connolly, Stuart J
2007-08-01
Although several randomized trials have detected no reduction in major cardiovascular events with the routine use of dual-chamber as opposed to ventricular pacemakers, many individuals continue to advocate their use as a means of improving exercise capacity. The Canadian Trial of Physiological Pacing (CTOPP) trial is the largest trial comparing ventricular pacing to atrial-based pacing (atrial or dual-chamber) in patients with bradycardia. All patients in this trial were asked to complete a 6-minute hall walk test (6MWT) at the time of their first study follow-up. The distance walked in 6 minutes and the patient's heart rate before and immediately after the walk were recorded. Of the 2568 patients in the CTOPP, 76% completed the 6MWT. The mean distance walked was 350 +/- 127 m in the ventricular pacing group and 356 +/- 127 m in the atrial-based group (P = NS). Similarly, there was no difference in the change in heart rate between the two groups (17 +/- 13 vs. 18 +/- 12 bpm: P = NS). However, among patients with an unpaced heart rate of =60 bpm, patients assigned to atrial-based pacing walked farther than those randomized to ventricular pacing (361 +/- 127 vs. 343 +/- 121 m; P = .04). This was not associated with a difference in heart rate. The use of rate-adaptive pacing, irrespective of the pacing mode, resulted in a greater increase in heart rate with the 6MWT but no increase in the total distance walked. The routine use of atrial-based pacemakers, instead of ventricular pacemakers, does not improve exercise capacity, as measured by the 6MWT. However, patients with an unpaced heart rate of =60 bpm may achieve a modest increase in their exercise capacity with atrial-based pacing.
Ozcan, C; Jahangir, A; Friedman, P A; Patel, P J; Munger, T M; Rea, R F; Lloyd, M A; Packer, D L; Hodge, D O; Gersh, B J; Hammill, S C; Shen, W K
2001-04-05
In patients with atrial fibrillation that is refractory to drug therapy, radio-frequency ablation of the atrioventricular node and implantation of a permanent pacemaker are an alternative therapeutic approach. The effect of this procedure on long-term survival is unknown. We studied all patients who underwent ablation of the atrioventricular node and implantation of a permanent pacemaker at the Mayo Clinic between 1990 and 1998. Observed survival was compared with the survival rates in two control populations: age- and sex-matched members of the Minnesota population between 1970 and 1990 and consecutive patients with atrial fibrillation who received drug therapy in 1993. A total of 350 patients (mean [+/-SD] age, 68+/-11 years) were studied. During a mean of 36+/-26 months of follow-up, 78 patients died. The observed survival rate was significantly lower than the expected survival rate based on the general Minnesota population (P<0.001). Previous myocardial infarction (P<0.001), a history of congestive heart failure (P=0.02), and treatment with cardiac drugs after ablation (P=0.03) were independent predictors of death. Observed survival among patients without these three risk factors was similar to expected survival (P=0.43). None of the 26 patients with lone atrial fibrillation died during follow-up (37+/-27 months). The observed survival rate among patients who underwent ablation was similar to that among 229 controls with atrial fibrillation (mean age, 67+/-12 years) who received drug therapy (P=0.44). In the absence of underlying heart disease, survival among patients with atrial fibrillation after ablation of the atrioventricular node is similar to expected survival in the general population. Long-term survival is similar for patients with atrial fibrillation, whether they receive ablation or drug therapy. Control of the ventricular rate by ablation of the atrioventricular node and permanent pacing does not adversely affect long-term survival.
Ramirez, Alexies; Gentlesk, Philip J; Peele, Mark E; Eckart, Robert E
2012-07-01
Device therapy is becoming common in those patients with renal insufficiency. Coexisting need for arteriovenous (AV) fistula placement is often contemplated relative to device placement. We describe the excimer laser lead extraction of a malfunctioning chronic atrial pacemaker lead ipsilateral to an AV fistula.
Issa, Ziad F
2007-09-01
Atrioventricular junction (AVJ) ablation combined with permanent pacemaker implantation (the "ablate and pace" approach) remains an acceptable alternative treatment strategy for symptomatic, drug-refractory atrial fibrillation (AF) with rapid ventricular response. This case series describes the feasibility and safety of catheter ablation of the AVJ via a superior vena caval approach performed during concurrent dual-chamber pacemaker implantation. A total of 17 consecutive patients with symptomatic, drug-refractory, paroxysmal AF underwent combined AVJ ablation and dual-chamber pacemaker implantation procedure using a left axillary venous approach. Two separate introducer sheaths were placed into the axillary vein. The first sheath was used for implantation of the pacemaker ventricular lead, which was then connected to the pulse generator. Subsequently, a standard ablation catheter was introduced through the second axillary venous sheath and used for radiofrequency (RF) ablation of the AVJ. After successful ablation, the catheter was withdrawn and the pacemaker atrial lead was advanced through that same sheath and implanted in the right atrium. Catheter ablation of the AVJ was successfully achieved in all patients. The median number of RF applications required to achieve complete AV block was three (range 1-10). In one patient, AV conduction recovered within the first hour after completion of the procedure, and AVJ ablation was then performed using the conventional femoral venous approach. There were no procedural complications. Catheter ablation of the AVJ can be performed successfully and safely via a superior vena caval approach in patients undergoing concurrent dual-chamber pacemaker implantation.
RUSSO, VINCENZO; NIGRO, GERARDO; RAGO, ANNA; ANTONIO PAPA, ANDREA; PROIETTI, RICCARDO; DELLA CIOPPA, NADIA; CRISTIANO, ANNA; PALLADINO, ALBERTO; CALABRÒ, RAFFAELE; POLITANO, LUISA
2013-01-01
The role that atrial pacing therapy plays on the atrial fibrillation (AF) burden is still unclear. Aim of the study was to evaluate the effect of the atrial preference pacing algorithm on AF burden in patients affected by Myotonic Dystrophy type 1 (DM1) followed for a long follow up period. Sixty DM1 patients were -implanted with a dual chamber pacemaker (PM) for first degree or symptomatic type 1/type 2 second degree atrio-ventricular blocks- were followed for 2-years after implantation, by periodical examination. After 1 month of stabilization, they were randomized into two groups: 1) Patients implanted with conventional dual-chamber pacing mode (DDDR group) and 2) Patients implanted with DDDR plus Atrial Preference Pacing (APP) algorithm (APP ON group). The results showed that atrial tachycardia (AT)/AF burden was significantly reduced at 1 year follow up in the APP ON group (2122 ± 428 minutes vs 4127 ± 388 minutes, P = 0.03), with a further reduction at the end of the 2 year follow up period (4652 ± 348 minutes vs 7564 ± 638 minutes, P = 0.005). The data here reported show that the APP is an efficient algorithm to reduce AT/AF burden in DM1 patients implanted with dual chamber pacemaker. PMID:24803841
[Long-term effects of permanent pacemaker implantation on tricuspid valve regurgitation].
Ren, Chong-lei; Wang, Yao; Wang, Rong; Li, Bo-jun; Geng, Ren-yi; Gao, Chang-qing
2012-08-14
To explore the long-term effects of permanent pacemaker implantation (PPI) on tricuspid valve regurgitation (TR) in Chinese patients so as to determine the incidence and related factors, evaluate its effects on heart structure and function and ascertain the exact mechanism of TR after PPI. A total of 430 patients undergoing permanent pacemaker replacement at our hospital between January 2000 and June 2011 were recruited. The patients with isolated atrial lead implantation procedures, significant heart valve disease or chronic obstructive pulmonary disease were excluded. The data of 108 patients who had Doppler echocardiograms performed before the first pacemaker implantation procedure and this pacemaker replacement procedure were obtained and retrospectively analyzed. According to the post-implant grade of TR, the patients were divided into two groups: normal tricuspid (n = 79) and abnormal tricuspid (n = 29). Their clinical characteristics and echocardiographic data between two groups were analyzed and compared. The mean follow-up time (from the first pacemaker implantation) was (13 ± 6) years (range: 4 - 34). Among 108 patients with initially normal tricuspid post-implant, 29 patients (26.9%) developed significant TR during the follow-up. In comparison to those in normal tricuspid group, the patients in abnormal tricuspid group had a longer time from the first pacemaker implantation ((16 ± 7) vs (12 ± 5) years, P = 0.003), more transtricuspid leads (1.31 ± 0.66 vs 1.10 ± 0.30, P = 0.026), larger right atrial size ((38 ± 7) vs (35 ± 4) mm, P = 0.028) and higher prevalence of mild TR and mitral valve regurgitation (MR) pre-implantation (TR: 21% vs 4%, P = 0.015, MR: 28% vs 5%, P = 0.003). The size of right atrium, right ventricle and left atrium in abnormal tricuspid group were more than those in normal tricuspid group. The prevalence of significant MR post-implantation in abnormal tricuspid group was higher than that in normal tricuspid group. The ejection fraction in abnormal tricuspid group was lower than that in normal tricuspid group during the follow-up. Abnormal TR after PPI during a long-term follow-up is quite common. The related factors include the time interval from the first pacemaker implantation, number of transtricuspid lead, right atrial size, mild TR and MR pre-implantation.
How smart should pacemakers Be?
Saoudi, N; Appl, U; Anselme, F; Voglimacci, M; Cribier, A
1999-03-11
The concept of the "smart" pacemaker has been continuously changing during 40 years of progress in technology. When we talk today about smart pacemakers, it means optimal treatment, diagnosis, and follow-up for patients fitting the current indications for pacemakers. So what is smart today becomes accepted as "state of the art" tomorrow. Originally, implantable pacemakers were developed to save lives from prolonged episodes of bradycardia and/or complete heart block. Now, in addition, they improve quality of life via numerous different functions acting under specific conditions, thanks to the introduction of microprocessors. The devices have become smaller, with the miniaturization of the electrical components, without compromising longevity. Nevertheless, there are still some unmatched objectives for these devices, for example, the optimization of cardiac output and the management of atrial arrhythmias in dual-chamber devices. Furthermore, indications continue to evolve, which in turn require new, additional functions. These functions are often very complex, necessitating computerized programming to simplify application. In addition, the follow-up of these devices is time-consuming, as appropriate system performance has to be regularly monitored. A great many of these functions could be automatically performed and documented, thus enabling physicians and paramedical staff to avoid losing time with routine control procedures. In addition, modern pacemakers offer extensive diagnostic functions to help diagnose patient symptoms and pacemaker system problems. Different types of data are available, and their presentation differs from one company to the other. This huge amount of data can only be managed with automatic diagnostic functions. Thus, the smart pacemaker of the near future should offer high flexibility to permit easy programming of available therapies and follow-up, and extensive, easily comprehensible diagnostic functions.
Karjalainen, Pasi P; Nammas, Wail; Paana, Tuomas
2016-01-01
An 83-year-old lady had a DDDR pacemaker inserted in 1997 for symptomatic atrioventricular block. She underwent battery replacement in 2008. In 2010, she developed atrial fibrillation; the pacemaker was switched to VVIR mode. During the last 2years, ventricular lead threshold increased progressively. In December 2015, she presented for elective battery replacement. After successful battery replacement, the ventricular lead threshold remained high; therefore, we implanted a leadless transcatheter pacemaker, via femoral vein access, using a dedicated catheter delivery system. Electrical measurements at this stage revealed a pacing threshold of 0.28V at 0.24msec, and an impedance of 650Ω. Copyright © 2016 Elsevier Inc. All rights reserved.
Recovery of Ventriculo-Atrial Conduction after Adrenaline in Patients Implanted with Pacemakers.
Cismaru, Gabriel; Gusetu, Gabriel; Muresan, Lucian; Rosu, Radu; Andronache, Marius; Matuz, Roxana; Puiu, Mihai; Mester, Petru; Miclaus, Maria; Pop, Dana; Mircea, Petru Adrian; Zdrenghea, Dumitru
2015-07-01
Ventriculo-atrial (VA) conduction can have negative consequences for patients with implanted pacemakers and defibrillators. There is concern whether impaired VA conduction could recover during stressful situations. Although the influence of isoproterenol and atropine are well established, the effect of adrenaline has not been studied systematically. The objective of this study was to determine if adrenaline can facilitate recovery of VA conduction in patients implanted with pacemakers. A prospective study was conducted on 61 consecutive patients during a 4-month period (April-July 2014). The presence of VA conduction was assessed during the pacemaker implantation procedure. In case of an impaired VA conduction, adrenaline infusio was used as a stress surrogate to test conduction recovery. The indications for pacemaker implantation were: sinus node dysfunction in 18 patients, atrioventricular (AV) block in 40 patients, binodal dysfunction (sinus node+ AV node) in two patients and other (carotid sinus syndrome) in one patient. In the basal state, 15/61 (24.6%) presented spontaneous VA conduction and 46/61 (75.4%) had no VA conduction. After administration of adrenaline, there was VA conduction recovery in 5/46 (10.9%) patients. Adrenaline infusion produced recovery of VA conduction in 10.9% of patients with absent VA conduction in a basal state. Recovery of VA conduction during physiological or pathological stresses could be responsible for the pacemaker syndrome, PMT episodes, or certain implantable cardiac defibrillator detection issues. © 2015 Wiley Periodicals, Inc.
Sutton, R; Fröhlig, G; de Voogt, W G; Goethals, M; Hintringer, F; Kennergren, C; Scanu, P; Guilleman, D; Treese, N; Hartung, W M; Stammwitz, E; Muetstege, A
2004-11-01
This study investigated the ability to minimize pace polarization artefacts (PPA) by adjusting the post-stimulus pulse duration of a tri-phasic stimulation pulse. Adjustment of the stimulation pulse was enabled by downloading special study software into an already implanted pacemaker. Tests were performed in a total of 296 atrial leads and 311 ventricular leads. Both chronic and acute leads were included in the study. Statistically significant differences were found in the initial PPA (without any adjustment of the stimulus pulse) between atrial and ventricular leads. In addition, significant differences were observed among various lead models with respect to changes over time in the initial ventricular PPA. Successful PPA reduction was defined as a reduction of the PPA below 0.5 mV for atrial leads and below 1 mV for ventricular leads. Results show a success rate for ventricular and atrial PPA reduction of 97.8% and 98.7%, respectively. Threshold tests showed that after reduction of the PPA loss of ventricular capture can be reliably detected. However, atrial threshold tests showed many false positive evoked response detections. In addition, unexpectedly high evoked response amplitudes were observed in the atrium after reduction of the PPA. Results from additional measurements suggest that these high atrial evoked response amplitudes come from the influence of the input filter of the pacemaker.
Use of an Atrial Lead with Very Short Tip-To-Ring Spacing Avoids Oversensing of Far-Field R-Wave
Kolb, Christof; Nölker, Georg; Lennerz, Carsten; Jetter, Hansmartin; Semmler, Verena; Pürner, Klaus; Gutleben, Klaus-Jürgen; Reents, Tilko; Lang, Klaus; Lotze, Ulrich
2012-01-01
Objective The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming. Methods Patients receiving a dual chamber pacemaker were randomly assigned to receive an atrial lead with a tip-to-ring spacing of 1.1 mm or a lead with a conventional tip-to-ring spacing of 10 mm. Postventricular atrial blanking (PVAB) was programmed to the shortest possible value of 60 ms in the study group, and to an individually determined optimized value in the control group. Atrial sensing threshold was programmed to 0.3 mV in both groups. False positive mode switch caused by FFS was evaluated at one and three months post implantation. Results A total of 204 patients (121 male; age 73±10 years) were included in the study. False positive mode switch caused by FFS was detected in one (1%) patient of the study group and two (2%) patients of the control group (p = 0.62). Conclusion The use of an atrial electrode with a very short tip-to-ring spacing avoids inappropriate mode switch caused by FFS without the need for individual PVAB optimization. Trial Registration ClinicalTrials.gov NCT00512915 PMID:22745661
Use of an atrial lead with very short tip-to-ring spacing avoids oversensing of far-field R-wave.
Kolb, Christof; Nölker, Georg; Lennerz, Carsten; Jetter, Hansmartin; Semmler, Verena; Pürner, Klaus; Gutleben, Klaus-Jürgen; Reents, Tilko; Lang, Klaus; Lotze, Ulrich
2012-01-01
The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming. Patients receiving a dual chamber pacemaker were randomly assigned to receive an atrial lead with a tip-to-ring spacing of 1.1 mm or a lead with a conventional tip-to-ring spacing of 10 mm. Postventricular atrial blanking (PVAB) was programmed to the shortest possible value of 60 ms in the study group, and to an individually determined optimized value in the control group. Atrial sensing threshold was programmed to 0.3 mV in both groups. False positive mode switch caused by FFS was evaluated at one and three months post implantation. A total of 204 patients (121 male; age 73±10 years) were included in the study. False positive mode switch caused by FFS was detected in one (1%) patient of the study group and two (2%) patients of the control group (p = 0.62). The use of an atrial electrode with a very short tip-to-ring spacing avoids inappropriate mode switch caused by FFS without the need for individual PVAB optimization. ClinicalTrials.gov NCT00512915.
Gene- and cell-based bio-artificial pacemaker: what basic and translational lessons have we learned?
Li, RA
2012-01-01
Normal rhythms originate in the sino-atrial node, a specialized cardiac tissue consisting of only a few thousands of pacemaker cells. Malfunction of pacemaker cells due to diseases or aging leads to rhythm generation disorders (for example, bradycardias and sick-sinus syndrome (SSS)), which often necessitate the implantation of electronic pacemakers. Although effective, electronic devices are associated with such shortcomings as limited battery life, permanent implantation of leads, lead dislodging, the lack of autonomic responses and so on. Here, various gene- and cell-based approaches, with a particular emphasis placed on the use of pluripotent stem cells and the hyperpolarization-activated cyclic nucleotide-gated-encoded pacemaker gene family, that have been pursued in the past decade to reconstruct bio-artificial pacemakers as alternatives will be discussed in relation to the basic biological insights and translational regenerative potential. PMID:22673497
Gene- and cell-based bio-artificial pacemaker: what basic and translational lessons have we learned?
Li, R A
2012-06-01
Normal rhythms originate in the sino-atrial node, a specialized cardiac tissue consisting of only a few thousands of nodal pacemaker cells. Malfunction of pacemaker cells due to diseases or aging leads to rhythm generation disorders (for example, bradycardias and sick-sinus syndrome (SSS)), which often necessitate the implantation of electronic pacemakers. Although effective, electronic devices are associated with such shortcomings as limited battery life, permanent implantation of leads, lead dislodging, the lack of autonomic responses and so on. Here, various gene- and cell-based approaches, with a particular emphasis placed on the use of pluripotent stem cells and the hyperpolarization-activated cyclic nucleotide-gated-encoded pacemaker gene family, that have been pursued in the past decade to reconstruct bio-artificial pacemakers as alternatives will be discussed in relation to the basic biological insights and translational regenerative potential.
Transarterial pacemaker lead implantation results in acute myocardial infarction.
Issa, Ziad F; Gill, John B
2010-11-01
We report a case of inadvertent transarterial implantation of dual-chamber pacemaker leads; the ventricular lead positioned across the aortic valve into the left ventricle and the atrial lead curving in the aortic root with the tip positioned into the left circumflex artery, resulting in acute myocardial infarction. The diagnosis was made based on the finding on the chest X-ray, surface ECG, and coronary angiography.
Mechanism underlying impaired cardiac pacemaking rhythm during ischemia: A simulation study
NASA Astrophysics Data System (ADS)
Bai, Xiangyun; Wang, Kuanquan; Yuan, Yongfeng; Li, Qince; Dobrzynski, Halina; Boyett, Mark R.; Hancox, Jules C.; Zhang, Henggui
2017-09-01
Ischemia in the heart impairs function of the cardiac pacemaker, the sinoatrial node (SAN). However, the ionic mechanisms underlying the ischemia-induced dysfunction of the SAN remain elusive. In order to investigate the ionic mechanisms by which ischemia causes SAN dysfunction, action potential models of rabbit SAN and atrial cells were modified to incorporate extant experimental data of ischemia-induced changes to membrane ion channels and intracellular ion homeostasis. The cell models were incorporated into an anatomically detailed 2D model of the intact SAN-atrium. Using the multi-scale models, the functional impact of ischemia-induced electrical alterations on cardiac pacemaking action potentials (APs) and their conduction was investigated. The effects of vagal tone activity on the regulation of cardiac pacemaker activity in control and ischemic conditions were also investigated. The simulation results showed that at the cellular level ischemia slowed the SAN pacemaking rate, which was mainly attributable to the altered Na+-Ca2+ exchange current and the ATP-sensitive potassium current. In the 2D SAN-atrium tissue model, ischemia slowed down both the pacemaking rate and the conduction velocity of APs into the surrounding atrial tissue. Simulated vagal nerve activity, including the actions of acetylcholine in the model, amplified the effects of ischemia, leading to possible SAN arrest and/or conduction exit block, which are major features of the sick sinus syndrome. In conclusion, this study provides novel insights into understanding the mechanisms by which ischemia alters SAN function, identifying specific conductances as contributors to bradycardia and conduction block.
Hemodynamic instability after pulmonary veins isolation in a patient with dual chamber pacemaker
Kiuchi, Márcio Galindo; Lobato, Guilherme Miglioli; Chen, Shaojie
2017-01-01
Abstract Introduction: The standard treatment of sinus node dysfunction (SND) is the pacemaker implantation, and the ideal methodology for the management of atrial fibrillation (AF) is rhythm control, but this is sometimes very hard to accomplish. For such actions, complete isolation of all pulmonary veins (PVI) is currently widely accepted as the best endpoint. Case Presentation: In this case, we report a female patient, 81 years old, with controlled hypertension, without coronary artery disease, bearer of bilateral knee replacement, and dual chamber pacemaker implanted 1.5 years ago owing to sinus node disease, presenting the following symptoms: presyncope episodes associated with sustained irregular palpitation tachycardia. The evaluation of the pacemaker-recorded episodes of atrial fibrillation, the echocardiogram-presented normal systolic function and measurements, as well as the resting myocardial scintigraphy and with drug use did not demonstrate ischemia and/or fibrosis. The patient was in use of valsartan 320 mg daily, amlodipine 10 mg daily, sotalol hydrochloride 120 mg 2 times daily, and dabigatran 110 mg 2 times daily. At the end of the PVI, the patient presented hemodynamic instability, with a decrease in heart rate to 30 bpm and invasive arterial blood pressure to 60/30 mmHg. The pericardial puncture was quickly carried out with the possibility of cardiac tamponade as the first hypothesis, but no pericardial effusion was found. Next, we detected acute capture loss from the ventricular pacemaker lead, unvarying with high voltage and pulse width, even with stable impedance, sense and keeping the same position visualized by fluoroscopy. And there was soon afterwards induction of sustained ventricular tachycardia degenerating to spontaneous ventricular fibrillation. Electrical cardioversion-defibrillation was performed with 200J, and the sinus rhythm was reestablished, but there was a dead short, and the pacemaker generator was burned and disabled. Conclusions: So, we can speculate that application of atrial radiofrequency for PVI diffused through the tissues, affecting in some way the tip of the ventricular electrode, causing a microlesion in this structure and making it impossible to capture the right ventricle by the pacemaker. As we cannot see it, we can call it of phantom injury of the ventricular lead. PMID:28562571
Kiuchi, Márcio Galindo; Lobato, Guilherme Miglioli; Chen, Shaojie
2017-06-01
The standard treatment of sinus node dysfunction (SND) is the pacemaker implantation, and the ideal methodology for the management of atrial fibrillation (AF) is rhythm control, but this is sometimes very hard to accomplish. For such actions, complete isolation of all pulmonary veins (PVI) is currently widely accepted as the best endpoint. In this case, we report a female patient, 81 years old, with controlled hypertension, without coronary artery disease, bearer of bilateral knee replacement, and dual chamber pacemaker implanted 1.5 years ago owing to sinus node disease, presenting the following symptoms: presyncope episodes associated with sustained irregular palpitation tachycardia. The evaluation of the pacemaker-recorded episodes of atrial fibrillation, the echocardiogram-presented normal systolic function and measurements, as well as the resting myocardial scintigraphy and with drug use did not demonstrate ischemia and/or fibrosis. The patient was in use of valsartan 320 mg daily, amlodipine 10 mg daily, sotalol hydrochloride 120 mg 2 times daily, and dabigatran 110 mg 2 times daily. At the end of the PVI, the patient presented hemodynamic instability, with a decrease in heart rate to 30 bpm and invasive arterial blood pressure to 60/30 mmHg. The pericardial puncture was quickly carried out with the possibility of cardiac tamponade as the first hypothesis, but no pericardial effusion was found. Next, we detected acute capture loss from the ventricular pacemaker lead, unvarying with high voltage and pulse width, even with stable impedance, sense and keeping the same position visualized by fluoroscopy. And there was soon afterwards induction of sustained ventricular tachycardia degenerating to spontaneous ventricular fibrillation. Electrical cardioversion-defibrillation was performed with 200J, and the sinus rhythm was reestablished, but there was a dead short, and the pacemaker generator was burned and disabled. So, we can speculate that application of atrial radiofrequency for PVI diffused through the tissues, affecting in some way the tip of the ventricular electrode, causing a microlesion in this structure and making it impossible to capture the right ventricle by the pacemaker. As we cannot see it, we can call it of phantom injury of the ventricular lead.
Nowak, Bernd; Tasche, Karl; Barnewold, Linda; Heller, Günther; Schmidt, Boris; Bordignon, Stefano; Chun, K R Julian; Fürnkranz, Alexander; Mehta, Rajendra H
2015-05-01
Several studies demonstrated an inverse relationship between cardioverter-defibrillator implantation volume and complication rates, suggesting better outcomes for higher volume centres. However, the association of institutional procedural volume with patient outcomes for permanent pacemaker (PPM) implantation remains less known, especially in decentralized implantation systems. We performed retrospective examination of data on patients undergoing PPM from the German obligatory quality assurance programme (2007-12) to evaluate the relationship of hospital PPM volume (categorized into quintiles of their mean annual volume) with risk-adjusted in-hospital surgical complications (composite of pneumothorax, haemothorax, pericardial effusion, or pocket haematoma, all requiring intervention, or device infection) and pacemaker lead dislocation. Overall 430 416 PPM implantations were documented in 1226 hospitals. Systems included dual (72.8%) and single (25.8%) chamber PPM and cardiac resynchronization therapy (CRT) devices (1.1%). Complications included surgical (0.92%), and ventricular (0.99%), and atrial (1.22%) lead dislocation. Despite an increase in relatively complex procedures (dual chamber, CRT), there was a significant decrease in the procedural and fluoroscopy times and complications from lowest to highest implantation volume quintiles (P for trend <0.0001). The greatest difference was observed between the lowest (1-50 implantations/year-reference group) and the second-lowest (51-90 implantations/year) quintile: surgical complications [odds ratio (OR) 0.69; confidence interval (CI) 0.60-0.78], atrial lead dislocations (OR 0.69; CI 0.59-0.80), and ventricular lead dislocations (OR 0.73; CI 0.63-0.84). Hospital annual PPM volume was directly related to indication-based implantation of relatively more complex PPM and yet inversely with procedural times and rates of early surgical complications and lead dislocations. Thus, our data suggest better performance and lower complications with increasing procedural volume. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Levy, T; Walker, S; Mason, M; Spurrell, P; Rex, S; Brant, S; Paul, V
2001-01-01
OBJECTIVE—To determine the importance of rhythm regulation or rate control in patients with permanent atrial fibrillation (AF) and normal left ventricular function. PATIENTS AND INTERVENTIONS—Thirty six patients with a mixed fast and slow ventricular response rate to their AF were randomised to either His bundle ablation (HBA) and VVIR pacemaker (HBA group) or VVI pacemaker and atrioventricular modifying drugs (Med group). Outcomes assessed at one, three, six, and 12 months included exercise duration and quality of life. RESULTS—Exercise duration significantly improved from baseline in both groups. There was no difference in outcome between the groups (Med +40% v HBA +20%, p = NS). The heart rate profile on exercise was similarly slowed in both groups compared to baseline. Quality of life significantly improved in both treatment arms for the modified Karolinska questionnaire (KQ) (Med +50% v HBA +50%, p = NS) and the Nottingham health profile (NHP) (Med +40% v HBA +20%, p = NS). However, for the individual symptom scores of each questionnaire more were improved in the Med group (KQ-Med 6 improved v HBA 4, NHP-Med 3 v HBA 1). Left ventricular function was equally preserved by both treatments during follow up. CONCLUSION—In these patients control of ventricular response rate with either HBA + VVIR pacemaker or atrioventricular modifying drugs + VVI pacemaker will lead to a significant improvement in exercise duration and quality of life. Rhythm regulation by HBA did not confer additional benefit, suggesting rate control alone is necessary for the successful symptomatic treatment of these patients in permanent AF. Keywords: ablation; atrial fibrillation; pacemaker; atrioventricular modifying drugs PMID:11156667
Michel, Miriam; Egender, Friedemann; Heßling, Vera; Dähnert, Ingo; Gebauer, Roman
2016-01-01
Background Postoperative junctional ectopic tachycardia (JET) occurs frequently after pediatric cardiac surgery. R-wave synchronized atrial (AVT) pacing is used to re-establish atrioventricular synchrony. AVT pacing is complex, with technical pitfalls. We sought to establish and to test a low-cost simulation model suitable for training and analysis in AVT pacing. Methods A simulation model was developed based on a JET simulator, a simulation doll, a cardiac monitor, and a pacemaker. A computer program simulated electrocardiograms. Ten experienced pediatric cardiologists tested the model. Their performance was analyzed using a testing protocol with 10 working steps. Results Four testers found the simulation model realistic; 6 found it very realistic. Nine claimed that the trial had improved their skills. All testers considered the model useful in teaching AVT pacing. The simulation test identified 5 working steps in which major mistakes in performance test may impede safe and effective AVT pacing and thus permitted specific training. The components of the model (exclusive monitor and pacemaker) cost less than $50. Assembly and training-session expenses were trivial. Conclusions A realistic, low-cost simulation model of AVT pacing is described. The model is suitable for teaching and analyzing AVT pacing technique. PMID:26943363
Kassotis, John; Voigt, Louis; Mongwa, Mbu; Reddy, C V R
2005-01-01
The objective of this study was to assess the feasibility of DDD pacing from a standard single-pass VDD pacemaker system. Over the past 2 decades significant advances have been made in the development of single-pass VDD pacing systems. These have been shown in long-term prospective studies to effectively preserve atrioventricular (AV)synchrony in patients with AV block and normal sinus node function. What remains problematic is the development of a single-pass pacing system capable of DDD pacing. Such a lead configuration would be useful in those patients with peripheral venous anomalies and in younger patients with congenital anomalies, which may require lead revisions in the future. In addition, with the increased use of resynchronization (biventricular pacing) therapy, the availability of a reliable single-pass lead will minimize operative time, enhance patient safety, and minimize the amount of hardware within the heart. The feasibility of DDD pacing via a Medtronic Capsure VDD-2 (Model #5038) pacing lead was evaluated. Twenty patients who presented with AV block and normal sinus node function were recruited for this study. Atrial pacing thresholds and sensitivities were assessed intraoperatively in the supine position with various respiratory maneuvers. Five patients who agreed to participate in long-term follow-up received a dual-chamber generator and were evaluated periodically over a 12-month period. Mean atrial sensitivity was 2.35 +/- 0.83 mV at the time of implantation. Effective atrial stimulation was possible in all patients at the time of implantation (mean stimulation threshold 3.08 +/- 1.04 V at 0.5 ms [bipolar], 3.34 +/- 0.95 V at 0.5 ms [unipolar]). Five of the 20 patients received a Kappa KDR701 generator, and atrial electrical properties were followed up over a 1-year period. There was no significant change in atrial pacing threshold or incidence of phrenic nerve stimulation over the 1-year follow-up. A standard single-pass VDD pacing lead system was capable of DDD pacing intraoperatively and during long-term follow-up. Despite higher than usual thresholds via the atrial dipole, pacemaker telemetry revealed < 10% use of atrial pacing dipole over a 12-month period, which would minimally deplete the pacemaker's battery. In addition, the telemetry confirmed appropriate sensing and pacing of the atrial dipole throughout the study period. At this time such systems can serve as back-up DDD pacing systems with further refinements required to optimize atrial thresholds in all patients.
Pacemaker mediated tachycardia as a complication of the autointrinsic conduction search function.
Dennis, Malcolm J; Sparks, Paul B
2004-06-01
The autointrinsic conduction search (AICS) option, featured on some DDD pacemakers, performs periodic assessments of atrioventricular (AV) conduction capability during a single beat AV delay extension. Demonstration of ventricular conduction during the prolonged AV delay, permits ongoing AV delay extension if the patient's intrinsic conduction is preferred to ventricular pacing. A case is presented where the wide separation of atrial and ventricular pacing during the conduction search permitted retrograde ventriculoatrial conduction, precipitating pacemaker mediated tachycardia (PMT) on seven occasions in one patient. Two onset patterns are reported, both attributable to the AICS option. Recommendations for prevention strategies are made.
Pustovit, K B; Abramochkin, D V
2016-04-01
Effects of nucleotide polyphosphate compounds (nicotinamide adenine dinucleotide, NAD(+); diadenosine tetraphosphate, Ap4A) on the confi guration of action potentials were studied in isolated preparations of guinea pig sinoatrial node and right atrial appendage (auricle). In the working myocardium, NAD(+) and Ap4A in concentrations of 10(-5) and 10(-4) M had no effect on resting potential, but significantly reduced the duration of action potentials; the most pronounced decrease was found at 25% repolarization. In the primary pacemaker of the sinoatrial node, both concentrations of NAD(+) and Ap4A induced hyperpolarization and reduction in the rate of slow diastolic depolarization, but significant slowing of the sinus rhythm was produced by these substances only in the concentration of 10(-4) M. Moreover, AP shortening and marked acceleration of AP upstroke were observed in the pacemaker myocardium after application of polyphosphates. Comparative analysis of the effects of NAD(+) and Ap4A in the working and pacemaker myocardium drove us to a hypothesis on inhibitory effects of these substances on L-type calcium current accompanied by stimulation of one or several potassium currents, which induce enhancement of repolarization and hyperpolarization of membranes probably mediated by the activation of purine receptors.
Shepard, Suzanne M; Tejman-Yarden, Shai; Khanna, Sandeep; Davis, Christopher K; Batra, Anjan S
2011-01-01
Dexmedetomidine (DEX; Precedex) is an alpha-2 adrenergic receptor agonist that produces anxiolysis and sleep-like sedation without narcosis or respiratory depression and has relatively few cardiovascular side effects. Given its favorable sedative properties combined with its limited effects on hemodynamic and respiratory function, it is widely used in pediatric intensive care and anesthesia settings. Case report. Pediatric intensive care unit. A three-yr-old girl was admitted after mitral valve replacement for persistent severe mitral insufficiency. Her prior history was significant for tetralogy of Fallot which was repaired at nine months of age. A year later the patient developed mitral and tricuspid valve insufficiency and subsequently underwent mitral and tricuspid valve repair, pulmonary valve replacement, and a maze procedure (the latter was performed for persistent atrial flutter). Following that operation she developed sinus node dysfunction and had a permanent epicardial dual-chamber pacemaker implanted. Due to remaining severe mitral insufficiency the patient had increasing pulmonary symptoms, necessitating the most recent surgery to replace her mitral valve. On postoperative day two the patient was hemodynamically stable and weaning off mechanical ventilation. Tracheal extubation was anticipated to occur within the next 24 hrs. A DEX infusion of 0.6 mcg/kg/hr was initiated. A pacemaker interrogation performed on postoperative day three, 21 hrs after the initiation of DEX, revealed unsuccessful atrial capture. Dexmedetomidine was subsequently discontinued and the patient's pacemaker was reinterrogated. The interrogation findings were similar to those seen prior to the initiation of DEX. As a result of these findings, caution is warranted in the administration of DEX to patients with predisposing conduction abnormalities and patients who are pacemaker-dependent.
Impact of high-grade Atrioventricular block and cumulative frequent pacing on atrial arrhythmias.
Wali, Eisha; Deshmukh, Amrish; Bukari, Abdallah; Broman, Michael; Aziz, Zaid; Beaser, Andrew; Upadhyay, Gaurav; Nayak, Hemal M; Tung, Roderick; Ozcan, Cevher
2018-06-21
The relationship between high-grade AV block (HGAVB) with cumulative frequent pacing and risk of atrial arrhythmias (AAs) has not been well characterized. We hypothesized HGAVB and pacing may have significant impact on incidence and prevalence of AAs by modulating atrial substrate. To determine impact of HGAVB and pacing on AAs including atrial fibrillation (AF), atrial flutter (AFL), and atrial tachycardia (AT). All consecutive patients who underwent dual chamber pacemaker implantation for HGAVB from 2005 to 2011 at the University of Chicago were included. AAs and percent of pacing were detected through device interrogation. Patients' data were collected from electronic medical records and clinic visits. A total of 166 patients (mean age 71±15 years; 54% female, 56% African-American) were studied. AF was documented in 27% of patients before pacemaker implantation. During a mean 5.8±2.2 years of follow-up, 47% had device-detected AF, 10% AFL and 26% AT. New-onset AF was documented in 40 of the 122 patients without prior AF (33%). Continuous (≥99%) right ventricular pacing was associated with significantly decreased AF prevalence (34% versus 59%, p = 0.005), and correlated with lower incidence (26% versus 41%, p = 0.22). Pacing suppressed AF in 14% of patients with baseline AF; those patients had lower atrial pacing (3.2% versus 45%, p < 0.0001). Left atrial dilation was the only independent predictor of AF with frequent pacing (p = 0.009). HGAVB is associated with high incidence and prevalence of AAs with and without pacing. Cumulative frequent (≥99%) ventricular pacing reduces risk of AF in patients with HGAVB. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Boriani, Giuseppe; Manolis, Antonis S; Tukkie, Raymond; Mont, Lluis; Pürerfellner, Helmut; Santini, Massimo; Inama, Giuseppe; Serra, Paolo; Gulizia, Michele; Samoilenko, Igor Vasilyevich; Wolff, Claudia; Holbrook, Reece; Gavazza, Federica; Padeletti, Luigi
2015-06-01
Many patients who suffer from bradycardia and need cardiac pacing also have atrial fibrillation (AF). New pacemaker algorithms, such as atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), have been specifically designed to reduce AF occurrence and duration and to minimize the detrimental effects of right ventricular pacing. The randomized MINimizE Right Ventricular pacing to prevent Atrial fibrillation and heart failure trial established that DDDRP + MVP pacing modality reduced permanent AF in bradycardia patients as compared with standard dual-chamber pacing (DDDR). The aim of this study was to estimate the cost savings due to lower AF-related health care utilization events based on health care costs from the United States and the European Union. Dual-chamber pacemaker patients with a history of paroxysmal or persistent AF were randomly assigned to receive DDDR (n = 385) or the advanced features (DDDRP + MVP; n = 383). We used published health care costs from the United States and the European Union (Italy, Spain, and the United Kingdom) to estimate the costs associated with AF-related hospitalizations and emergency visits. The rate of AF-related hospitalizations was significantly lower in the DDDRP + MVP group than in the conventional pacemaker group (DDDR group; 42% reduction; incidence rate ratio 0.58). Similarly, a significant reduction of 68% was observed for AF-related emergency department visits (incidence rate ratio 0.32; P < .001). As a consequence, DDDRP + MVP could potentially reduce health care costs by 40%-44%. Over a ten-year period, the cost savings per 100 patients ranged from $35,702 in the United Kingdom to $121,831 in the United States. New pacing algorithms such as DDDRP + MVP used in the MINimizE Right Ventricular pacing to prevent Atrial fibrillation and heart failure trial successfully reduced AF-related health care utilization, resulting in significant cost savings to payers. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
De Pasquale, Gabriella; Bonassin Tempesta, Francesca; Lopes, Bruno Santos; Babic, Daniela; Oxenius, Angela; Seeliger, Theresa; Gruner, Christiane; Tanner, Felix C; Biaggi, Patric; Attenhofer Jost, Christine; Greutmann, Matthias
2017-05-01
To determine the prevalence of baffle leaks in adults after atrial switch operations for transposition of the great arteries, as these may predispose to paradoxical embolic events, particularly in patients with transvenous pacemaker or defibrillator leads. We routinely perform contrast echocardiography with agitated saline in all patients after atrial switch operations. For this study, we analysed patients who had saline contrast echocardiography between 2010 and 2012. The presence of baffle leaks and the severity of right-to-left shunting were assessed. We compared baseline characteristics and oxygen saturation at rest and during exercise between patients with and without baffle leaks. A total of 65 patients (56 Senning and 9 Mustard repair) without previously known baffle leaks were included (mean age 32 ± 8 years, 77% males). Right-to-left shunting was identified in 42 patients (65%) and occurred without provocation manoeuvres in 88%. There were no differences in baseline characteristics, echocardiographic findings, or exercise capacity between patients with and without baffle leaks, except for lower oxygen saturation at peak exercise in those with baffle leaks (29% had oxygen saturations below 90% at peak exercise compared to none without baffle leaks, P = 0.011). Four patients with baffle leaks had previous implantation of transvenous pacemaker leads; one of them had suffered a stroke. Two other patients with baffle leaks had a history of potential embolic stroke. Because of the high prevalence of baffle leaks in adults after atrial switch operations, we propose routine screening with agitated saline contrast, particularly prior to implantation of transvenous pacemaker or defibrillator leads. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Novel approach to epicardial pacemaker implantation in patients with limited venous access.
Costa, Roberto; Scanavacca, Mauricio; da Silva, Kátia Regina; Martinelli Filho, Martino; Carrillo, Roger
2013-11-01
Limited venous access in certain patients increases the procedural risk and complexity of conventional transvenous pacemaker implantation. The purpose of this study was to determine a minimally invasive epicardial approach using pericardial reflections for dual-chamber pacemaker implantation in patients with limited venous access. Between June 2006 and November 2011, 15 patients underwent epicardial pacemaker implantation. Procedures were performed through a minimally invasive subxiphoid approach and pericardial window with subsequent fluoroscopy-assisted lead placement. Mean patient age was 46.4 ± 15.3 years (9 male [(60.0%], 6 female [40.0%]). The new surgical approach was used in patients determined to have limited venous access due to multiple abandoned leads in 5 (33.3%), venous occlusion in 3 (20.0%), intravascular retention of lead fragments from prior extraction in 3 (20.0%), tricuspid valve vegetation currently under treatment in 2 (13.3%), and unrepaired intracardiac defects in 2 (13.3%). All procedures were successful with no perioperative complications or early deaths. Mean operating time for isolated pacemaker implantation was 231.7 ± 33.5 minutes. Lead placement on the superior aspect of right atrium, through the transverse sinus, was possible in 12 patients. In the remaining 3 patients, the atrial lead was implanted on the left atrium through the oblique sinus, the postcaval recess, or the left pulmonary vein recess. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 36.8 ± 25.1 months. Epicardial pacemaker implantation through pericardial reflections is an effective alternative therapy for those patients requiring physiologic pacing in whom venous access is limited. © 2013 Heart Rhythm Society. All rights reserved.
Focal Atrial Tachycardia Arising from the Inferior Vena Cava
Lim, Yeong-Min; Uhm, Jae-Sun
2017-01-01
The inferior vena cava (IVC) is a rare site of focal atrial tachycardia (AT). Here, we report a 20-year-old woman who underwent catheter ablation for anti-arrhythmic drug-resistant AT originating from the IVC. She had undergone open-heart surgery for patch closure of an atrial septal defect 17 years previously and permanent pacemaker implantation for sinus node dysfunction 6 years previously. The AT focus was at the anterolateral aspect of the IVC-right atrial junction, and it was successfully ablated under three-dimensional electroanatomical-mapping guidance. We suspect that the mechanism of this tachycardia was associated with previous IVC cannulation for open-heart surgery. PMID:28541006
Tang, Gilbert H L; Kaple, Ryan; Cohen, Martin; Dutta, Tanya; Undemir, Cenap; Ahmad, Hasan; Poniros, Angelica; Bennett, Joanne; Feng, Cheng; Lansman, Steven
2017-02-03
Pacemaker lead-associated severe tricuspid regurgitation (TR) can lead to right heart failure and poor prognosis. Surgery in these patients carries significant morbidities. We describe a successful treatment of symptomatic severe TR by leadless pacemaker implantation followed by tricuspid valve (TV) repair with the MitraClip NT. A 71-year-old frail female with poor functional status, chronic atrial fibrillation and permanent pacemaker implantation in 2012 presented with symptomatic moderate-severe mitral regurgitation (MR) and severe TR with the pacemaker lead as the culprit. She was deemed extreme risk for double valve surgery and, because of her pacemaker dependency, the decision was to stage her interventions first with transcatheter mitral repair, then laser lead extraction and leadless pacemaker implantation to free the TV from tethering, then TV repair. An obstructive LAD lesion was identified and treated during mitral repair with the MitraClip NT. The Micra leadless pacemaker implantation and subsequent TV repair with the MitraClip NT were successful and the patient's MR improved to mild and TR to moderate, respectively. We report here a first successful transcatheter strategy to treat lead-associated severe TR by leadless pacemaker and MitraClip. Removing the pacemaker lead relieved leaflet tethering and improved the reparability of the TV.
Atrio-ventricular junction ablation and pacemaker treatment: a comparison between men and women.
Carnlöf, Carina; Insulander, Per; Jensen-Urstad, Mats; Iwarzon, Marie; Gadler, Fredrik
2018-06-01
To explore sex differences regarding indication for atrio-ventricular junction ablation (AVJ), choice of pacing system, complications to pacemaker treatment, long-term outcome, and cause of death after AVJ ablation. 700 patients who had undergone AVJ ablation between January 1990 and December 2010 were included. Data were retrieved from the patients´ medical records and the Swedish Pacemaker and Implantable Cardioverter-Defibrillator Registry. Information about admission to hospital and cause of death was retrieved from the National Board of Health and Welfare. Mean follow-up was 90 ± 64 months. Indication for AVJ ablation, choice of pacing system, and outcome after AVJ ablation differed between the sexes. The men had more often permanent atrial fibrillation, p = .0001, and a VVIR pacemaker or cardiac resynchronization therapy (CRT) implanted prior to ablation, p = .0001. Heart failure was present in 44% of the men vs. 28% of the women, p = .0001. LVEF decreased slightly in the whole cohort after the AVJ ablation. There were no sex differences in complication rates due to the pacemaker/ICD treatment, p = .3 or mortality due to AVJ ablation. In this long-term follow-up in patients with atrial fibrillation treated with AVJ ablation and pacing, indication, choice of pacing system, and morbidity differed but there were no sex differences regarding survival or primary cause of death found. The main factor influencing survival was age at the time of ablation. Women less often received treatment with ICD and/or CRT when indication was present compared with men.
Kanadaşı, Mehmet; Caylı, Murat; Sahin, Durmuş Yıldıray; Sen, Ömer; Koç, Mevlüt; Usal, Ayhan; Batur, Mustafa Kemal; Demirtaş, Mustafa
2011-07-01
Although it has been known that optimization of atrioventricular delay (AVD) has favorable effect on the left ventricular functions in patients with DDD pacemaker, the effect of different AVDs on left atrium (LA) and left atrial appendage (LAA) functions has not been exactly evaluated. The aim of the present study was to assess the effect of different AVDs on LA and LAA functions in DDD pacemaker implanted patients with atrioventricular block. Forty-eight patients with DDD pacemaker were enrolled into the study. Patients were divided into two groups according to the echocardiographic diastolic function: Group I (normal diastolic function) and Group II (diastolic dysfunction). LAA emptying velocity on pulsed wave Doppler and LAA late systolic wave velocity by using tissue Doppler were recorded. Patients were paced for five successive continuous pacing periods of 10 minutes duration using five selective AVDs (80-250 ms). Significant effect on LA and LAA functions has not been observed by the setting of AVD in Group I. However, when the AVD was gradually shortened form 150 ms to 80 ms, LA and LAA functions gradually decreased in Group II patients. When AVD increased to 200 ms, LA and LAA functions were improved. Further increase in AVD resulted in decreased LA and LAA functions. Setting of AVD has not significant effect on the LA and LAA functions in patients with normal diastolic function, but moderate prolongation of AVD in physiological limits improved LA and LAA functions in DDD pacemaker implanted patients with diastolic dysfunction. © 2011, Wiley Periodicals, Inc.
Evaluation of a New Cardiac Pacemaker
2013-06-25
Atrial Fibrillation With 2 or 3° AV or Bifascicular Bundle Branch (BBB) Block; Normal Sinus Rhythm With 2 or 3° AV or BBB Block; Sinus Bradycardia With Infrequent Pauses or Unexplained Syncope With EP Findings
Surgical ablation of atrial fibrillation during mitral-valve surgery.
Gillinov, A Marc; Gelijns, Annetine C; Parides, Michael K; DeRose, Joseph J; Moskowitz, Alan J; Voisine, Pierre; Ailawadi, Gorav; Bouchard, Denis; Smith, Peter K; Mack, Michael J; Acker, Michael A; Mullen, John C; Rose, Eric A; Chang, Helena L; Puskas, John D; Couderc, Jean-Philippe; Gardner, Timothy J; Varghese, Robin; Horvath, Keith A; Bolling, Steven F; Michler, Robert E; Geller, Nancy L; Ascheim, Deborah D; Miller, Marissa A; Bagiella, Emilia; Moquete, Ellen G; Williams, Paula; Taddei-Peters, Wendy C; O'Gara, Patrick T; Blackstone, Eugene H; Argenziano, Michael
2015-04-09
Among patients undergoing mitral-valve surgery, 30 to 50% present with atrial fibrillation, which is associated with reduced survival and increased risk of stroke. Surgical ablation of atrial fibrillation has been widely adopted, but evidence regarding its safety and effectiveness is limited. We randomly assigned 260 patients with persistent or long-standing persistent atrial fibrillation who required mitral-valve surgery to undergo either surgical ablation (ablation group) or no ablation (control group) during the mitral-valve operation. Patients in the ablation group underwent further randomization to pulmonary-vein isolation or a biatrial maze procedure. All patients underwent closure of the left atrial appendage. The primary end point was freedom from atrial fibrillation at both 6 months and 12 months (as assessed by means of 3-day Holter monitoring). More patients in the ablation group than in the control group were free from atrial fibrillation at both 6 and 12 months (63.2% vs. 29.4%, P<0.001). There was no significant difference in the rate of freedom from atrial fibrillation between patients who underwent pulmonary-vein isolation and those who underwent the biatrial maze procedure (61.0% and 66.0%, respectively; P=0.60). One-year mortality was 6.8% in the ablation group and 8.7% in the control group (hazard ratio with ablation, 0.76; 95% confidence interval, 0.32 to 1.84; P=0.55). Ablation was associated with more implantations of a permanent pacemaker than was no ablation (21.5 vs. 8.1 per 100 patient-years, P=0.01). There were no significant between-group differences in major cardiac or cerebrovascular adverse events, overall serious adverse events, or hospital readmissions. The addition of atrial fibrillation ablation to mitral-valve surgery significantly increased the rate of freedom from atrial fibrillation at 1 year among patients with persistent or long-standing persistent atrial fibrillation, but the risk of implantation of a permanent pacemaker was also increased. (Funded by the National Institutes of Health and the Canadian Institutes of Health Research; ClinicalTrials.gov number, NCT00903370.).
[Ventricular tachycardia in a patient with rate-responsive cardiac pacemaker].
Himbert, C; Lascault, G; Tonet, J; Coutte, R; Busquet, P; Frank, R; Grosgogeat, Y
1992-11-01
The authors report a case of syncopal ventricular tachycardia in a patient with a respiratory-dependent rate responsive pacemaker, followed-up for valvular heart disease with severe left ventricular dysfunction and sustained atrial and ventricular arrhythmias. The introduction of low dose betablocker therapy with reinforcement of the treatment of cardiac failure controlled the ventricular arrhythmia, after suppression of the data responsive function had been shown to be ineffective. The authors discuss the role of the rate responsive function in the triggering of the ventricular tachycardias.
Inadvertent transarterial insertion of atrial and ventricular defibrillator leads.
Issa, Ziad F; Rumman, Syeda S; Mullin, James C
2009-01-01
Inadvertent placement of pacemaker and implantable cardioverter-defibrillator (ICD) leads in the left ventricle (LV) is a rare but well-recognized complication of device implantation [1]. We report a case of inadvertent transarterial implantation of dual-chamber ICD leads; the ventricular lead positioned in the LV and the atrial lead positioned in the aortic root. The tip of the atrial lead migrated across the aortic wall and captured the epicardial surface of the left atrium. The diagnosis was made 5 years after the implantation procedure with no apparent adverse events directly related to left heart lead placement.
Boriani, Giuseppe; Tukkie, Raymond; Manolis, Antonis S; Mont, Lluis; Pürerfellner, Helmut; Santini, Massimo; Inama, Giuseppe; Serra, Paolo; de Sousa, João; Botto, Giovanni Luca; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi
2014-09-14
Atrial fibrillation (AF) is a common comorbidity in bradycardia patients. Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), which minimizes unnecessary right ventricular pacing. We evaluated whether DDDRP and MVP might reduce mortality, morbidity, or progression to permanent AF when compared with standard dual-chamber pacing (Control DDDR). In a randomized, parallel, single-blind, multi-centre trial we enrolled 1300 patients with bradycardia and previous atrial tachyarrhythmias, in whom a DDDRP pacemaker had recently been implanted. History of permanent AF and third-degree atrioventricular block were exclusion criteria. After a 1-month run-in period, 1166 eligible patients, aged 74 ± 9 years, 50% females, were randomized to Control DDDR, DDDRP + MVP, or MVP. Analysis was intention-to-treat. The primary outcome, i.e. the 2-year incidence of a combined endpoint composed of death, cardiovascular hospitalizations, or permanent AF, occurred in 102/385 (26.5%) Control DDDR patients, in 76/383 (19.8%) DDDRP + MVP patients [hazard ratio (HR) = 0.74, 95% confidence interval 0.55-0.99, P = 0.04 vs. Control DDDR] and in 85/398 (21.4%) MVP patients (HR = 0.89, 95% confidence interval 0.77-1.03, P = 0.125 vs. Control DDDR). When compared with Control DDDR, DDDRP + MVP reduced the risk for AF longer than 1 day (HR = 0.66, 95% CI 0.52-0.85, P < 0.001), AF longer than 7 days (HR = 0.52, 95% CI 0.36-0.73, P < 0.001), and permanent AF (HR = 0.39, 95% CI 0.21-0.75, P = 0.004). In patients with bradycardia and atrial tachyarrhythmias, DDDRP + MVP is superior to standard dual-chamber pacing. The primary endpoint was significantly lowered through the reduction of the progression of atrial tachyarrhythmias to permanent AF. NCT00262119. © The Author 2014. Published by Oxford University Press on behalf of the European Society of Cardiology.
Re-use of explanted DDD pacemakers as VDD- clinical utility and cost effectiveness.
Namboodiri, K K N; Sharma, Y P; Bali, H K; Grover, A
2004-01-01
Re-use of DDD pulse generators explanted from patients died of unrelated causes is associated with an additional cost of two transvenous leads if implanted as DDD itself, and high rate of infection according to some studies. We studied the clinical and economical aspects of reutilization of explanted DDD pacemakers programmed to VDD mode. Out of 28 patients who received VDD pacemaker during the period, October 2000- September 2001 in the Department of Cardiology, PGIMER, Chandigarh, 5 poor patients were implanted with explanted DDD pulse generators programmed to VDD mode. Each implantation was planned and carried out according to a standard protocol. The age ranged from 45 to 75 (mean-61) years. The indications for pacing were complete heart block (4) and second degree AV block (1). The clinical profile, costs and complications, if any were noted and followed up at regular intervals. The results were compared with patients who received new DDD pulse generators during this period. The additional cost for the atrial lead was not required in these patients. None of these patients had any local site infection. Compared to the two-lead system, the single lead system provided more rapid implantation and minimized complications associated with placement of an atrial lead. The explanted DDD pacemaker can be safely reused as VDD mode with same efficacy in selected patient population. This is associated with lower cost and complications compared to reimplantation as DDD itself.
Kim, Won Ho; Joung, Boyoung; Shim, Jaemin; Park, Jong Sung; Hwang, Eui-Seock; Pak, Hui-Nam; Kim, Sungsoon
2010-01-01
Purpose The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. Materials and Methods Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared. Results The baseline characteristics were comparable between the two groups, with a mean follow-up duration of 69 months. The incidence of death did not show statistical difference. However, the incidence of hospitalization for congestive heart failure (CHF) was significantly lower in the AAI(R) group (0%) than the DDD(R) group (8.8%, p = 0.03). Also, atrial fibrillation (AF) was found in 2.8% in the AAI(R) group, which was statistically different from 15.2% of patients in the DDD(R) group (p = 0.01). Four patients (5.5%) with AAI(R) developed AV block, and subsequently switched to DDD(R) pacing. The risk of AF was lower in the patients implanted with AAI(R) than those with DDD(R) [hazard ratio (HR), 0.84; 95% confidence interval, 0.72 to 0.97, p = 0.02]. Conclusion In patients with SND and intact AV conduction, AAI(R) pacing can achieve a better clinical outcome in terms of occurrence of CHF and AF than DDD(R) pacing. These findings support AAI(R) pacing as the preferred pacing mode in patients with SND and intact AV conduction. PMID:20879047
Monigatti-Tenkorang, Joanna; Jousset, Florian; Pascale, Patrizio; Vesin, Jean-Marc; Ruchat, Patrick; Fromer, Martin; Narayan, Sanjiv M; Pruvot, Etienne
2014-04-01
Paroxysmal atrial fibrillation (AF) may be triggered by intermittent atrial tachycardia, and ultimately lead to persistent AF. However, the mechanisms by which intermittent atrial tachycardia promotes sustained AF are not well understood. Eight sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms, and for the delivery of electrophysiological stimulation protocols and intermittent right atrial tachycardia. Right atrial kinetics of activation recovery interval (ARI) as a surrogate for action potential duration, of conduction time and velocity, and of repolarization alternans were analyzed at incremental pacing rates during the remodeling process induced by weeks of intermittent atrial tachycardia until the development of sustained AF. Intermittent atrial tachycardia decreased ARI and blunted its rate adaptation, facilitated atrial capture, and slowed conduction at high rates, and increased susceptibility to pacing-induced AF. In spite of blunted ARI rate adaptation, right atrial repolarization alternans was maintained during remodeling, and further increased in magnitude just before rapid pacing-induced AF. This study suggests that weeks of intermittent right atrial tachycardia result in a gradual electrical remodeling favorable for wavebreaks and reentry that may facilitate fibrillation. © 2014 Wiley Periodicals, Inc.
Mo, Bin-Feng; Lu, Qiu-Fen; Lu, Shang-Biao; Xie, Yu-Quan; Feng, Xiang-Fei; Li, Yi-Gang
2017-08-20
The CHA2DS2-VASc score is used clinically for stroke risk stratification in patients with atrial fibrillation (AF). We sought to investigate whether the CHA2DS2-VASc score predicts stroke and death in Chinese patients with sick sinus syndrome (SSS) after pacemaker implantation and to evaluate whether the predictive power of the CHA2DS2-VASc score could be improved by combining it with left atrial diameter (LAD) and amino-terminal pro-brain natriuretic peptide (NT-proBNP). A total of 481 consecutive patients with SSS who underwent pacemaker implantation from January 2004 to December 2014 in our department were included. The CHA2DS2-VASc scores were retrospectively calculated according to the hospital medical records before pacemaker implantation. The outcome data (stroke and death) were collected by pacemaker follow-up visits and telephonic follow-up until December 31, 2015. During 2151 person-years of follow-up, 46 patients (9.6%) suffered stroke and 52 (10.8%) died. The CHA2DS2-VASc score showed a significant association with the development of stroke (hazard ratio [HR] 1.45, 95% confidence interval [CI] 1.20-1.75, P< 0.001) and death (HR 1.45, 95% CI 1.22-1.71, P< 0.001). The combination of increased LAD and the CHA2DS2-VASc score improved the predictive power for stroke (C-stat 0.69, 95% CI 0.61-0.77 vs. C-stat 0.66, 95% CI 0.57-0.74, P= 0.013), and the combination of increased NT-proBNP and the CHA2DS2-VASc score improved the predictive power for death (C-stat 0.70, 95% CI 0.64-0.77 vs. C-stat 0.67, 95% CI 0.60--0.75, P= 0.023). CHA2DS2-VASc score is valuable for predicting stroke and death risk in patients with SSS after pacemaker implantation. The addition of LAD and NT-proBNP to the CHA2DS2-VASc score improved its predictive power for stroke and death, respectively, in this patient cohort. Future prospective studies are warranted to validate the benefit of adding LAD and NT-proBNP to the CHA2DS2-VASc score for predicting stroke and death risk in non-AF populations.
Third-generation mobile phones (UMTS) do not interfere with permanent implanted pacemakers.
Ismail, Mohamed M; Badreldin, Akmal M A; Heldwein, Matthias; Hekmat, Khosro
2010-07-01
Third-generation mobile phones, UMTS (Universal Mobile Telecommunication System), were recently introduced in Europe. The safety of these devices with regard to their interference with implanted pacemakers is as yet unknown and is the point of interest in this study. The study comprised 100 patients with permanent pacemaker implantation between November 2004 and June 2005. Two UMTS cellular phones (T-Mobile, Vodafone) were tested in the standby, dialing, and operating mode with 23 single-chamber and 77 dual-chamber pacemakers. Continuous surface electrocardiograms (ECGs), intracardiac electrograms, and marker channels were recorded when calls were made by a stationary phone to cellular phone. All pacemakers were tested under a "worst-case scenario," which includes a programming of the pacemaker to unipolar sensing and pacing modes and inducing of a maximum sensitivity setting during continuous pacing of the patient. Patients had pacemaker implantation between June 1990 and April 2005. The mean age was 68.4 +/- 15.1 years. Regardless of atrial and ventricular sensitivity settings, both UMTS mobile phones (Nokia 6650 and Motorola A835) did not show any interference with all tested pacemakers. In addition, both cellular phones did not interfere with the marker channels and the intracardiac ECGs of the pacemakers. Third-generation mobile phones are safe for patients with permanent pacemakers. This is due to the high-frequency band for this system (1,800-2,200 MHz) and the low power output between 0.01 W and 0.25 W.
Wang, Xule; Zhao, Qingyan; Huang, He; Tang, Yanhong; Xiao, Jinping; Dai, Zixuan; Yu, Shengbo; Huang, Congxin
2013-01-01
We have previously demonstrated that catheter-based renal sympathetic denervation (RSD) could suppress atrial fibrillation (AF) in canines with short-time rapid right atrial pacing (RAP). However, the role of renal denervation on atrial remodeling is unclear. The aim of the present study was to explore the long-term effect of RSD on the atrial remodeling during prolonged RAP. Twenty mongrel dogs were implanted with a high-frequency cardiac pacemaker with a transvenous lead inserted into the right atrial appendage. The dogs were divided into three groups: a sham-operated group (n = 6), the chronic RAP (CRAP) group (n = 7), and the CRAP+RSD group (n = 7). In the CRAP+RSD group, a pacemaker was implanted 6 weeks after RSD was performed bilaterally for recovery. RAP was maintained for 5 weeks in CRAP group and CRAP+RSD group. The plasma levels of Angiotensin II and aldosterone were significantly increased in CRAP group compared with sham-operated group, but the increasing trend was inhibited in CRAP+RSD group compared with CRAP group (P<0.05). Similarly, RSD suppressed the increasing trend that prolonged RAP produced in the left atrial levels of ANP, TNF-α and IL-6. Compared with the sham-operated group, the CRAP group had significantly increased levels of caspase-3, bax and Cx40 whereas the level of Bcl-2 decreased (P<0.05). RSD markedly reduced the upregulation of caspase-3, bax and Cx40 and the downregulation of Bcl-2 expression compared with the CRAP group (P<0.05). Picric acid-sirius red staining study suggested that RSD could markedly alleviate the lesion degree of cardic fibrosis induced by CRAP (P<0.05). Immunohistochemistry results showed that the densities of TH- and GAP43- positive nerves were significantly elevated in the CRAP group compared with the sham-operated group, while RSD operation signicantly inhibited the these changes produced by CRAP. These findings suggest that renal denervation could suppress the atrial remodeling after prolonged RAP in ambulatory canines.
Wang, Xule; Zhao, Qingyan; Huang, He; Tang, Yanhong; Xiao, Jinping; Dai, Zixuan; Yu, Shengbo; Huang, Congxin
2013-01-01
We have previously demonstrated that catheter-based renal sympathetic denervation (RSD) could suppress atrial fibrillation (AF) in canines with short-time rapid right atrial pacing (RAP). However, the role of renal denervation on atrial remodeling is unclear. The aim of the present study was to explore the long-term effect of RSD on the atrial remodeling during prolonged RAP. Twenty mongrel dogs were implanted with a high-frequency cardiac pacemaker with a transvenous lead inserted into the right atrial appendage. The dogs were divided into three groups: a sham-operated group (n = 6), the chronic RAP (CRAP) group (n = 7), and the CRAP+RSD group (n = 7). In the CRAP+RSD group, a pacemaker was implanted 6 weeks after RSD was performed bilaterally for recovery. RAP was maintained for 5 weeks in CRAP group and CRAP+RSD group. The plasma levels of Angiotensin II and aldosterone were significantly increased in CRAP group compared with sham-operated group, but the increasing trend was inhibited in CRAP+RSD group compared with CRAP group (P<0.05). Similarly, RSD suppressed the increasing trend that prolonged RAP produced in the left atrial levels of ANP, TNF-α and IL-6. Compared with the sham-operated group, the CRAP group had significantly increased levels of caspase-3, bax and Cx40 whereas the level of Bcl-2 decreased (P<0.05). RSD markedly reduced the upregulation of caspase-3, bax and Cx40 and the downregulation of Bcl-2 expression compared with the CRAP group (P<0.05). Picric acid–sirius red staining study suggested that RSD could markedly alleviate the lesion degree of cardic fibrosis induced by CRAP (P<0.05). Immunohistochemistry results showed that the densities of TH- and GAP43- positive nerves were significantly elevated in the CRAP group compared with the sham-operated group, while RSD operation signicantly inhibited the these changes produced by CRAP. These findings suggest that renal denervation could suppress the atrial remodeling after prolonged RAP in ambulatory canines. PMID:23724069
Behavior of an Automatic Pacemaker Sensing Algorithm for Single-Pass VDD Atrial Electrograms
2001-10-25
830- s lead (Medico), during several different body postures, deep respiration, and walking. The algorithm had a pre - determined sensing dynamic range...SINGLE-PASS VDD ATRIAL ELECTROGRAMS J. Kim1, S.H. Lee1, S.Y.Yang2, B. S . Cho2, and W. Huh1 1Department of Electronics Engineering, Myongji...University, Yongin, Korea 2Department of Information and Communication, Dongwon College, Kwangju, Korea S T = 5 0 % x ( B + C ) / 2 S T = 5 0 % x ( A + B
Sucu, Murat; Davutoglu, Vedat; Ozer, Orhan
2009-01-01
External electrical cardioversion was first performed in the 1950s. Urgent or elective cardioversions have specific advantages, such as termination of atrial and ventricular tachycardia and recovery of sinus rhythm. Electrical cardioversion is life-saving when applied in urgent circumstances. The succcess rate is increased by accurate tachycardia diagnosis, careful patient selection, adequate electrode (paddles) application, determination of the optimal energy and anesthesia levels, prevention of embolic events and arrythmia recurrence and airway conservation while minimizing possible complications. Potential complications include ventricular fibrillation due to general anesthesia or lack of synchronization between the direct current (DC) shock and the QRS complex, thromboembolus due to insufficient anticoagulant therapy, non-sustained VT, atrial arrhythmia, heart block, bradycardia, transient left bundle branch block, myocardial necrosis, myocardial dysfunction, transient hypotension, pulmonary edema and skin burn. Electrical cardioversion performed in patients with a pacemaker or an incompatible cardioverter defibrillator may lead to dysfunction, namely acute or chronic changes in the pacing or sensitivity threshold. Although this procedure appears fairly simple, serious consequences might occur if inappropriately performed. PMID:19448376
Rejection of atrial sensing artifacts by a pacing lead with short tip-to-ring spacing.
Nash, A; Fröhlig, G; Taborsky, M; Stammwitz, E; Maru, F; Bouwens, L H M; Celiker, C
2005-01-01
The ability of a new pacing lead design, with a 10 mm tip-to-ring spacing, to facilitate rejection of sensed far field R-waves and myopotentials was evaluated. Measurements were performed in 66 patients. The occurrence of far field R-wave sensing and myopotential sensing was determined by means of the surface ECG and the ECG markers provided by the pacemaker. At an atrial sensitivity of 0.25 mV and an atrial blanking of 50 ms far field R-wave sensing was observed in 12 patients (18.2%) and at an atrial sensitivity of 1.0 mV no far-field R-wave sensing was observed. Myopotentials were sensed in 3 patients. In all patients the measured P-wave amplitude was at least twice the estimated amplitude of the far field R-wave at an atrial blanking of 50 ms. The results from this study show that a small tip-to-ring spacing allows for programming of a high atrial sensitivity and short atrial blanking with an acceptably low risk for atrial artifact sensing.
The interference of electronic implants in low frequency electromagnetic fields.
Silny, J
2003-04-01
Electronic implants such as cardiac pacemakers or nerve stimulators can be impaired in different ways by amplitude-modulated and even continuous electric or magnetic fields of strong field intensities. For the implant bearer, possible consequences of a temporary electromagnetic interference may range from a harmless impairment of his well-being to a perilous predicament. Electromagnetic interferences in all types of implants cannot be covered here due to their various locations in the body and their different sensing systems. Therefore, this presentation focuses exemplarily on the most frequently used implant, the cardiac pacemaker. In case of an electromagnetic interference the cardiac pacemaker reacts by switching to inhibition mode or to fast asynchronous pacing. At a higher disturbance voltage on the input of the pacemaker, a regular asynchronous pacing is likely to arise. In particular, the first-named interference could be highly dangerous for the pacemaker patient. The interference threshold of cardiac pacemakers depends in a complex way on a number of different factors such as: electromagnetic immunity and adjustment of the pacemaker, the composition of the applied low-frequency fields (only electric or magnetic fields or combinations of both), their frequencies and modulations, the type of pacemaker system (bipolar, unipolar) and its location in the body, as well as the body size and orientation in the field, and last but not least, certain physiological conditions of the patient (e.g. inhalation, exhalation). In extensive laboratory studies we have investigated the interference mechanisms in more than 100 cardiac pacemakers (older types as well as current models) and the resulting worst-case conditions for pacemaker patients in low-frequency electric and magnetic fields. The verification of these results in different practical everyday-life situations, e.g. in the fields of high-voltage overhead lines or those of electronic article surveillance systems is currently in progress. In case of the vertically-oriented electric 50 Hz fields preliminary results show that per 1 kV/m unimpaired electrical field strength (rms) an interference voltage of about 400 microVpp as worst-case could occur at the input of a unipolar ventricularly controlled, left-pectorally implanted cardiac pacemaker. Thus, already a field strength above ca. 5 kV/m could cause an interference with an implanted pacemaker. The magnetic fields induces an electric disturbance voltage at the input of the pacemaker. The body and the pacemaker system compose several induction loops, whose induced voltages rates add or subtract. The effective area of one representing inductive loop ranges from 100 to 221 cm2. For the unfavourable left-pectorally implantated and atrially-controlled pacemaker with a low interference threshold, the interference threshold ranges between 552 and 16 microT (rms) for magnetic fields at frequencies between 10 and 250 Hz. On this basis the occurrence of interferences with implanted pacemakers is possible in everyday-life situations. But experiments demonstrate a low probability of interference of cardiac pacemakers in practical situations. This apparent contradiction can be explained by a very small band of inhibition in most pacemakers and, in comparison with the worst-case, deviating conditions.
Morpho-functional characterization of the systemic venous pole of the reptile heart.
Jensen, Bjarke; Vesterskov, Signe; Boukens, Bastiaan J; Nielsen, Jan M; Moorman, Antoon F M; Christoffels, Vincent M; Wang, Tobias
2017-07-27
Mammals evolved from reptile-like ancestors, and while the mammalian heart is driven by a distinct sinus node, a sinus node is not apparent in reptiles. We characterized the myocardial systemic venous pole, the sinus venosus, in reptiles to identify the dominant pacemaker and to assess whether the sinus venosus remodels and adopts an atrium-like phenotype as observed in mammals. Anolis lizards had an extensive sinus venosus of myocardium expressing Tbx18. A small sub-population of cells encircling the sinuatrial junction expressed Isl1, Bmp2, Tbx3, and Hcn4, homologues of genes marking the mammalian sinus node. Electrical mapping showed that hearts of Anolis lizards and Python snakes were driven from the sinuatrial junction. The electrical impulse was delayed between the sinus venosus and the right atrium, allowing the sinus venosus to contract and aid right atrial filling. In proximity of the systemic veins, the Anolis sinus venosus expressed markers of the atrial phenotype Nkx2-5 and Gja5. In conclusion, the reptile heart is driven by a pacemaker region with an expression signature similar to that of the immature sinus node of mammals. Unlike mammals, reptiles maintain a sinuatrial delay of the impulse, allowing the partly atrialized sinus venosus to function as a chamber.
Bailey, William M; Mazur, Alexander; McCotter, Craig; Woodard, Pamela K; Rosenthal, Lawrence; Johnson, Whitney; Mela, Theofanie
2016-02-01
Permanent cardiac pacemakers have historically been considered a contraindication to magnetic resonance imaging (MRI). The purpose of the ProMRI Phase B Study, a multicenter, prospective, single-arm, nonrandomized study, was to evaluate the clinical safety of the Biotronik ProMRI pacemaker system in patients undergoing thoracic spine and cardiac MRI. The ProMRI Phase B study enrolled 245 patients with stable baseline pacing indices implanted with an Entovis pacemaker (DR-T or SR-T) and Setrox 53-cm and/or 60-cm lead(s). Device interrogation was performed at enrollment, pre- and post-MRI scan, and 1 and 3 months post-MRI. End-points were (1) freedom from MRI- and pacing system-related serious adverse device effects through 1 month post-MRI; (2) freedom from atrial and ventricular MRI-induced pacing threshold increase (>0.5 V); and (3) freedom from P- and R-wave amplitude attenuation (<50%), or P wave <1.5 mV, or R wave <5.0 mV at 1 month post-MRI. In total, 216 patients completed the MRI and 1-month post-MRI follow-up. One adverse event possibly related to the implanted system and the MRI procedure occurred, resulting in a serious adverse device effect-free rate of 99.6% (220/221; P < .0001. Freedom from atrial and ventricular pacing threshold increase was 100% (194/194, P < .001) and 100% (206/206, P < .001) respectively. Freedom from P- and R-wave amplitude attenuation was 98.2% (167/170, P < .001) and 100% (188/188, P < .001) respectively. The results of the ProMRI Phase B study demonstrate the clinical safety and efficacy of the ProMRI pacemaker system in patients subjected to thoracic spine and cardiac MRI conditions. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Bailey, William M; Rosenthal, Lawrence; Fananapazir, Lameh; Gleva, Marye; Mazur, Alexander; Rinaldi, C A; Kypta, Alexander; Merkely, Béla; Woodard, Pamela K
2015-06-01
Permanent cardiac pacemakers have historically been considered a contraindication to magnetic resonance imaging (MRI). The purpose of the ProMRI/ProMRI AFFIRM Study, which was a multicenter, prospective, single-arm, nonrandomized study, was to evaluate the clinical safety of the Biotronik ProMRI Pacemaker System under specific MRI conditions. The ProMRI Study (in the United States) and the ProMRI AFFIRM study (outside the United States) with identical design enrolled 272 patients with stable baseline pacing indices implanted with an Entovis or Evia pacemaker (DR-T or SR-T) and Setrox or Safio 53-cm or 60-cm lead. Device interrogation was performed at enrollment, pre-MRI and post-MRI scan, and 1 and 3 months post-MRI. End-points were (1) freedom from MRI- and pacing system-related serious adverse device effects (SADEs) through 1 month post-MRI, (2) freedom from atrial and ventricular MRI-induced pacing threshold increase (>0.5 V), and (3) freedom from P- and R-wave amplitude attenuation (<50%), or P wave <1.5 mV, or R wave <5.0 mV at 1 month post-MRI. Two hundred twenty-six patients completed the MRI and 1-month post-MRI follow-up. No adverse events related to the implanted system and the MRI procedure occurred, resulting in an SADE-free rate of 100.0% (229/229, P <.001). Freedom from atrial and ventricular pacing threshold increase was 99.0% (189/191, P = .003) and 100% (217/217, P <.001), respectively. Freedom from P- and R- wave amplitude attenuation was 99.4% (167/168, P <.001) and 99.5% (193/194, P <.001), respectively. The results of the ProMRI/ProMRI AFFIRM studies demonstrate the clinical safety and efficacy of the ProMRI pacemaker system in patients subjected to head and lower lumbar MRI conditions. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Mitov, Vladimir; Perisić, Zoran; Jolić, Aleksandar; Adamović, Dragana; Zastranović, Lale; Aleksić, Aleksandar; Kostić, Tomislav; Božinović, Nenad; Aleksić, Zeljka; Soldatović, Ivan
2013-01-01
Our aim was to analyze any changes during diastole in patients with normal left ventricular ejection fraction (LVEF), after pacemaker stimulation from the right ventricular outflow tract (RVOT) and right ventricular apex (RVA) lead position. This was a prospective, randomized, follow up study, which lasted for 12 months. Our research included 132 consecutive patients who were implanted with a permanent antibradycardiac pacemaker. Regarding the right ventricle lead position the patients were divided into two groups: The RVOT group--71 patients, with right ventricle outflow tract lead position and the RVA group--61 patients, with right ventricle apex lead position. We measured LVEF and diastolic parameters: peak filling ratio and time to peak filling ratio obtained by radionuclide ventriculography (RNV). The LVEF and various diastolic parameters and left atrial diameter were obtained by echocardiography. Based on the values of deceleration time of early diastolic filling (DTE), and other diastolic parameters like left atrial diameter, all the patients were classified into three degrees of diastolic dysfunction. Our results showed that there was no group difference in distribution of gender, age, body mass index (BMI), VVI to DDD pacemakers implantation ratio, RNV parameters (LVEF, peak filling rate (PFR), time to PFR (TPFR)) and echocardiography parameters: LVEF and parameters of diastolic dysfunction. After 12 months of pacemaker stimulation, LVEF by RNV remained the same in the RVOT group 51.31±15.80% (P=0.75), and also in the RVA group 53.83±6.57%, (P=0.19). In the RVOT group the PFR was highly lower and this finding was significant (P=0.01), while TPFR was also significantly lower (P=0.03). By dividing the patients according to the degree of diastolic dysfunction we found that most patients in both groups at enrollment had a second degree diastolic dysfunction. In both groups diastolic dysfunction increased, the number of patients with third degree diastolic dysfunction increased, and the number of patients with second degree diastolic dysfunction decreased, however, the worsening of diastolic function was significant only in the RVOT group. In conclusion, pacemaker stimulation from RVOT, but not in RVA, leads to progression of diastolic dysfunction in patients with preserved LVEF. This negative effect of pacemaker stimulation from RVOT on diastolic parameters was confirmed by two independent methods, RNV and echocardiography.
Ghaem, Haleh; Ghorbani, Mohammad; Zare Dorniani, Samira
2017-06-01
Permanent artificial pacemaker is one of the important therapies for treatment of cardiac conduction system problems. The present study aimed to determine the association between some predictive variables and all-cause and cause-specific mortality in the patients who had undergone pacemaker implantation. This study was conducted on 1207 patients who had undergone permanent pacemaker implantation in the hospitals affiliated with Shiraz University of Medical Sciences, Iran, from Mar 2002 to Mar 2012. The variables that existed in the patients' medical records included sex, diabetes mellitus, obesity, cerebrovascular accident, cardiomegaly, smoking, hypertension, ischemic heart disease, congenital heart disease, sick sinus syndrome, and atrial fibrillation. Competing risks model was used to assess the association between the predictive variables and cause-specific (i.e., cardiac and vascular) mortality. The patients' mean age was 66.32±17.92 yr (70.62±14.45 yr in the patients with single-chamber pacemakers vs. 61.91±17.69 yr in those with two-chamber pacemakers) ( P <0.001). Sick sinus syndrome and age increased the risk of all-cause mortality, while two-chamber pacemaker decreased this risk. Obesity increased the risk of cardiac death, and diabetes mellitus and heart valve disease increased the risk of vascular death. The variables predicting mortality in all-cause model were completely different from those in cause-specific model. Moreover, death in such patients may occur due to reasons other than pacemaker. Therefore, future studies, particularly prospective ones, are recommended to use competing risks models.
Takii, Eiichi; Inage, Tomohito; Yoshida, Teruhisa; Ohe, Masatsugu; Gondo, Takeki; Haraguchi, Go; Ito, Shogo; Kumanomido, Jun; Imaizumi, Tsutomu; Fukuomoto, Yoshihiro
2016-03-01
Renin-angiotensin system (RAS) inhibitors may be useful in preventing the occurrence of paroxysmal atrial fibrillation (PAF). However, evaluation of such effect is difficult because many PAF episodes are asymptomatic and not all episodes are detected by intermittent electrocardiographic monitoring. A pacemaker has been developed with dedicated functions for AF detection and electrocardiogram storage. Accordingly, we examined the effect of losartan, an angiotensin receptor blocker on PAF occurrence using this new modality. We enrolled 70 consecutive patients who had undergone dual-chamber pacemaker implantation for sick sinus syndrome. Finally, 62 patients participated in the study. Thirty patients were randomized to the losartan group (mean 43 ± 12 mg/day) and 32 patients to the control group. They were followed up for 3 months. The frequency, the maximum duration and the total duration of PAF recorded by the stored electrocardiograms for the last 1 month during the observation period and study period were compared between the two groups. The change in the frequency of PAF from the observation period in the losartan and control groups was similar (-35 ± 25 vs. -67 ± 62 times; NS). However, the change in the maximum duration and the total duration of PAF was significantly shorter in the losartan group than in the control group (-493 ± 158 vs. -10 ± 69 min; p < 0.05, and -4007 ± 2334 vs. 1119 ± 714 min; p < 0.05, respectively). Losartan suppressed the maximum duration and the total duration of PAF in patients with sick sinus syndrome without hemodynamic changes. This is the first study to show the effect of a renin-angiotensin system inhibitor on the secondary prevention of PAF using the dedicated functions of a pacemaker for PAF detection and electrocardiogram storage.
Yarlagadda, Bharath; Turagam, Mohit K; Dar, Tawseef; Jangam, Pragna; Veerapaneni, Vaishnavi; Atkins, Donita; Bommana, Sudharani; Friedman, Paul; Deshmukh, Abhishek J; Doshi, Rahul; Reddy, Vivek Y; Dukkipati, Srinivas R; Natale, Andrea; Lakkireddy, Dhanunjaya
2018-03-01
Atrioventricular node (AVN) ablation and permanent pacing is an established strategy for rate control in the management of symptomatic atrial fibrillation (AF). Leadless pacemakers (LPs) can overcome some of the short-term and long-term limitations of conventional transvenous pacemakers (CTPs). The purpose of this study was to compare the feasibility and safety of LP with those of single-chamber CTP in patients with AF undergoing AVN ablation. We conducted a multicenter observational study of patients undergoing AVN ablation and pacemaker implantation (LP vs single-chamber CTP) between February 2014 and November 2016. The primary efficacy end points were acceptable sensing (R wave ≥5.0 mV) and pacing thresholds (≤2.0 V at 0.4 ms) at follow-up. Safety end points included device-related major and minor (early ≤1 month, late >1 month) adverse events. A total of 127 patients with LP (n = 60) and CTP (n = 67) were studied. The median follow-up was 12 months (interquartile range 12-18 months). Ninety-five percent of the LP group and 97% of the CTP group met the primary efficacy end point at follow-up (57 of 60 vs 65 of 67; P = .66). There was 1 major adverse event (loss of pacing and sensing) in the LP group and 2 (lead dislodgement) in the CTP group (1 of 60 vs 2 of 67; P = 1.00). There were 6 minor adverse events (5 early and 1 late) in the LP group and 3 (early) in the CTP group (6 of 60 vs 3 of 67; P = .30). Our results demonstrate the feasibility and safety of LP compared with CTP in patients undergoing AVN ablation for AF. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
GHAEM, Haleh; GHORBANI, Mohammad; ZARE DORNIANI, Samira
2017-01-01
Background: Permanent artificial pacemaker is one of the important therapies for treatment of cardiac conduction system problems. The present study aimed to determine the association between some predictive variables and all-cause and cause-specific mortality in the patients who had undergone pacemaker implantation. Methods: This study was conducted on 1207 patients who had undergone permanent pacemaker implantation in the hospitals affiliated with Shiraz University of Medical Sciences, Iran, from Mar 2002 to Mar 2012. The variables that existed in the patients’ medical records included sex, diabetes mellitus, obesity, cerebrovascular accident, cardiomegaly, smoking, hypertension, ischemic heart disease, congenital heart disease, sick sinus syndrome, and atrial fibrillation. Competing risks model was used to assess the association between the predictive variables and cause-specific (i.e., cardiac and vascular) mortality. Results: The patients’ mean age was 66.32±17.92 yr (70.62±14.45 yr in the patients with single-chamber pacemakers vs. 61.91±17.69 yr in those with two-chamber pacemakers) (P<0.001). Sick sinus syndrome and age increased the risk of all-cause mortality, while two-chamber pacemaker decreased this risk. Obesity increased the risk of cardiac death, and diabetes mellitus and heart valve disease increased the risk of vascular death. Conclusion: The variables predicting mortality in all-cause model were completely different from those in cause-specific model. Moreover, death in such patients may occur due to reasons other than pacemaker. Therefore, future studies, particularly prospective ones, are recommended to use competing risks models. PMID:28828325
Cardiorespiratory interactions in patients with atrial flutter.
Masè, Michela; Disertori, Marcello; Ravelli, Flavia
2009-01-01
Respiratory sinus arrhythmia (RSA) is generally known as the autonomically mediated modulation of the sinus node pacemaker frequency in synchrony with respiration. Cardiorespiratory interactions have been largely investigated during sinus rhythm, whereas little is known about interactions during reentrant arrhythmias. In this study, cardiorespiratory interactions at the atrial and ventricular level were investigated during atrial flutter (AFL), a supraventricular arrhythmia based on a reentry, by using cross-spectral analysis and computer modeling. The coherence and phase between respiration and atrial (gamma(AA)(2), phi(AA)) and ventricular (gamma(RR)(2), phi(RR)) interval series were estimated in 20 patients with typical AFL (68.0 +/- 8.8 yr) and some degree of atrioventricular (AV) conduction block. In all patients, atrial intervals displayed oscillations strongly coupled and in phase with respiration (gamma(AA)(2)= 0.97 +/- 0.05, phi(AA) = 0.71 +/- 0.31 rad), corresponding to a paradoxical lengthening of intervals during inspiration. The modulation pattern was frequency independent, with in-phase oscillations and short time delays (0.40 +/- 0.15 s) for respiratory frequencies in the range 0.1-0.4 Hz. Ventricular patterns were affected by AV conduction type. In patients with fixed AV conduction, ventricular intervals displayed oscillations strongly coupled (gamma(RR)(2)= 0.97 +/- 0.03) and in phase with respiration (phi(RR) = 1.08 +/- 0.80 rad). Differently, in patients with variable AV conduction, respiratory oscillations were secondary to Wencheback rhythmicity, resulting in a decreased level of coupling (gamma(RR)(2)= 0.50 +/- 0.21). Simulations with a simplified model of AV conduction showed ventricular patterns to originate from the combination of a respiratory modulated atrial input with the functional properties of the AV node. The paradoxical frequency-independent modulation pattern of atrial interval, the short time delays, and the complexity of ventricular rhythm characterize respiratory arrhythmia during AFL and distinguish it from normal RSA. These peculiar features can be explained by assuming a direct mechanical action of respiration on AFL reentrant circuit.
Implantable automatic scanning pacemaker for termination of supraventricular tachycardia.
Spurrell, R A; Nathan, A W; Bexton, R S; Hellestrand, K J; Nappholz, T; Camm, A J
1982-03-01
Thirteen patients suffering from reentrant supraventricular tachycardia have undergone implantation of a scanning extrastimulus pacemaker. This pacemaker is fully implanted and automatic, and it requires no external control device to activate or control it. The pacemaker is activated when tachycardia occurs. After four cycles an extrastimulus is induced with a preset coupling time from a sensed intracardiac potential, and every four cycles thereafter a further extrastimulus occurs, but on each occasion there is a decrement in coupling cycle by 6 ms until 90 ms of the cardiac cycle has been scanned by extrastimuli. When necessary, two extrastimuli can be introduced with a fixed but preset coupling time between them. Every four beats two extrastimuli are induced but the coupling time between the spontaneous cardiac potential and the first stimulus is decreased by 6 ms until 90 ms of the cardiac cycle has been scanned. The coupling time between the two stimuli is fixed throughout the scan. When termination of tachycardia occurs the successful timing variables are retained in the pacemaker memory so that at the onset of the next episode of tachycardia these settings are used first. Pacemaker pulse width, sensitivity, tachycardia trigger rate, coupling intervals for both stimuli and the use of single or double extrastimuli are all programmable transcutaneously. Three patients required single, and seven patients double ventricular premature stimuli; three patients required double atrial premature stimuli for termination of tachycardia. Despite frequent attacks of tachycardia before implantation, only two patients had a sustained attack of tachycardia after pacemaker implantation.
Electromagnetic interference with pacemakers caused by portable media players.
Thaker, Jay P; Patel, Mehul B; Jongnarangsin, Krit; Liepa, Valdis V; Thakur, Ranjan K
2008-04-01
Electromagnetic fields generated by electrical devices may cause interference with permanent pacemakers. Media players are becoming a common mode of portable entertainment. The most common media players used worldwide are iPods. These devices are often carried in a shirt chest pocket, which may place the devices close to an implanted pacemaker. The purpose of this study was to determine if iPods cause interference with pacemakers. In this prospective, single-blinded study, 100 patients who had cardiac pacemakers were tested with four types of iPods to assess for interference. Patients were monitored by a single-channel ECG monitor as well as the respective pacemaker programmer via the telemetry wand. iPods were tested by placing them 2 inches anterior to the pacemaker and wand for up to 10 seconds. To simulate actual use, standard-issue headphones were plugged into the iPods. To maintain consistency, the volume was turned up maximally, and the equalizer was turned off. A subset of 25 patients underwent testing on 2 separate days to assess for reproducibility of interference. Pacemaker interference was categorized as type I or type II telemetry interference. Type I interference was associated with atrial and/or ventricular high rates on rate histograms. Type II interference did not affect pacemaker rate counters. Electromagnetic emissions from the four iPods also were evaluated in a Faraday cage to determine the mechanism of the observed interference. One hundred patients (63 men and 37 women; mean age 77.1 +/- 7.6 years) with 11 single-chamber pacemakers and 89 dual-chamber pacemakers underwent 800 tests. The incidence of any type of interference was 51% of patients and 20% of tests. Type I interference was seen in 19% of patients and type II in 32% of patients. Reproducibility testing confirmed that interference occurred regardless of pacing configuration (unipolar or bipolar), pacing mode (AAI, VVI, or DDD), and from one day to the next. Electromagnetic emissions testing from the iPods demonstrated maximum emissions in the pacemaker carrier frequency range when the iPod was turned "on" with the headphones attached. iPods placed within 2 inches of implanted pacemakers monitored via the telemetry wand can cause interference with pacemakers.
Lead-related complications after DDD pacemaker implantation.
Dębski, Maciej; Ulman, Mateusz; Ząbek, Andrzej; Boczar, Krzysztof; Haberka, Kazimierz; Kuniewicz, Marcin; Lelakowski, Jacek; Małecka, Barbara
2018-04-10
Pacing leads remain the weakest link in pacemaker systems despite advances in manufacturing technology. To assess the long-term pacing lead performance in an unselected real-life cohort following primary DDD pacing system implantation. A single-centre retrospective analysis of patients who underwent DDD pacing system implantation between October 1984 and December 2014 and were followed up until August 2016 was conducted. The inclusion criterion was at least one follow-up visit following post-implant discharge. The performance of each atrial and ventricular lead implanted was evaluated during the follow-up period, and the incidence of and predictive factors for lead dislodgement and failure were analysed. The data of 3771 patients and 24431.8 patient-years of follow-up were analysed. The mean follow-up of patients was 77.7 ± 61.8 months. During the study period, 7887 transvenous atrial and right ventricular pacing leads were implanted. Lead dislodgement occurred in 94 (1.2%) leads [92 (2.4%) patients], perforation in 11 (0.1%) leads [10 (0.3%) patients] and lead failure in 329 (4.2%) leads [275 (7.3%) patients]. Atrial lead position was a predictive factor for lead dislodgement, while age at implantation, polyurethane 80A insulation, subclavian vein access, unipolar lead construction and lead manufacturer were multivariate predictors of lead failure. Leads with polyurethane 80A insulation, unipolar construction and implantation via subclavian vein puncture exhibited the worst long-term performance.
Comparison of DDD versus VVIR pacing modes in elderly patients with atrioventricular block.
Kılıçaslan, Barış; Vatansever Ağca, Fahriye; Kılıçaslan, Esin Evren; Kınay, Ozan; Tigen, Kürşat; Cakır, Cayan; Nazlı, Cem; Ergene, Oktay
2012-06-01
Dual-chamber pacing is believed to have an advantage over single-chamber ventricular pacing. The aim of this study was to determine whether elderly patients who have implanted pacemakers for complete atrioventricular block gain significant benefits from dual-chamber (DDD) pacemakers compared with single chamber ventricular (VVIR) pacemakers. This study was designed as a randomized, two-period crossover study-each pacing mode was maintained for 1 month. Thirty patients (16 men, mean age 68.87 ± 6.89 years) with implanted DDD pacemakers were submitted to a standard protocol, which included an interview, pacemaker syndrome assessment, health related quality of life (HRQoL) questionnaires assessed by an SF-36 test, 6-minute walk test (6MWT), and transthoracic echocardiographic examinations. All of these parameters were obtained on both DDD and VVIR mode pacing. Paired data were compared. HRQoL scores were similar, and 6MWT results did not differ between the two groups. VVIR pacing elicited significant enlargement of the left atrium and impaired left ventricular diastolic functions as compared with DDD pacing. Two patients reported subclinical pacemaker syndrome, but this was not statistically significant. Our study revealed that in active elderly patients with complete heart block, DDD pacing and VVIR pacing yielded similar improvements in QoL and exercise performance. However, after a short follow-up period, we noted that VVIR pacing caused significant left atrial enlargement and impaired left ventricular diastolic functions.
Biteker, Murat; Duman, Dursun; Tekkeşin, Ahmet Ilker
2012-08-01
The utility of routine preoperative electrocardiography (ECG) for assessing perioperative cardiovascular risk in patients undergoing noncardiac, nonvascular surgery (NCNVS) is unclear. There would be an association between preoperative ECG and perioperative cardiovascular outcomes in patients undergoing NCNVS. A total of 660 patients undergoing NCNVS were prospectively evaluated. Patients age >18 years who underwent an elective, nonday case, open surgical procedure were enrolled. Troponin I concentrations and 12-lead ECG were evaluated the day before surgery, immediately after surgery, and on the first 5 postoperative days. Preoperative ECG showing atrial fibrillation, left or right bundle branch block, left ventricular hypertrophy, frequent premature ventricular complexes, pacemaker rhythm, Q-wave, ST-segment changes, or sinus tachycardia or bradycardia were classified as abnormal. The patients were followed up during hospitalization and were evaluated for the presence of perioperative cardiovascular events (PCE). Eighty patients (12.1%) experienced PCE. Patients with abnormal ECG findings had a greater incidence of PCE than those with normal ECG results (16% vs 6.4%; P < 0.001). Mean QTc interval was significantly longer in the patients who had PCE (436.6 ± 31.4 vs 413.3 ± 16.7 ms; P < 0.001). Univariate analysis showed a significant association between preoperative atrial fibrillation, pacemaker rhythm, ST-segment changes, QTc prolongation, and in-hospital PCE. However, only QTc prolongation (odds ratio: 1.15, 95% confidence interval: 1.06-1.2, P < 0.001) was an independent predictor of PCE according to the multivariate analysis. Every 10-ms increase in QTc interval was related to a 13% increase for PCE. Prolongation of the QTc interval on the preoperative ECG was related with PCE in patients undergoing NCNVS. © 2011 Wiley Periodicals, Inc.
Russell, Stuart J; Tan, Christine; O'Keefe, Peter; Ashraf, Saeed; Zaidi, Afzal; Fraser, Alan G; Yousef, Zaheer R
2012-02-20
Heart failure patients with stable angina, acute coronary syndromes and valvular heart disease may benefit from revascularisation and/or valve surgery. However, the mortality rate is increased- 5-30%. Biventricular pacing using temporary epicardial wires after surgery is a potential mechanism to improve cardiac function and clinical endpoints. A multi-centred, prospective, randomised, single-blinded, intervention-control trial of temporary biventricular pacing versus standard pacing. Patients with ischaemic cardiomyopathy, valvular heart disease or both, an ejection fraction ≤ 35% and a conventional indication for cardiac surgery will be recruited from 2 cardiac centres. Baseline investigations will include: an electrocardiogram to confirm sinus rhythm and measure QRS duration; echocardiogram to evaluate left ventricular function and markers of mechanical dyssynchrony; dobutamine echocardiogram for viability and blood tests for renal function and biomarkers of myocardial injury- troponin T and brain naturetic peptide. Blood tests will be repeated at 18, 48 and 72 hours. The principal exclusions will be subjects with permanent atrial arrhythmias, permanent pacemakers, infective endocarditis or end-stage renal disease.After surgery, temporary pacing wires will be attached to the postero-lateral wall of the left ventricle, the right atrium and right ventricle and connected to a triple chamber temporary pacemaker. Subjects will be randomised to receive either temporary biventricular pacing or standard pacing (atrial inhibited pacing or atrial-synchronous right ventricular pacing) for 48 hours.The primary endpoint will be the duration of level 3 care. In brief, this is the requirement for invasive ventilation, multi-organ support or more than one inotrope/vasoconstrictor. Haemodynamic studies will be performed at baseline, 6, 18 and 24 hours after surgery using a pulmonary arterial catheter. Measurements will be taken in the following pacing modes: atrial inhibited; right ventricular only; atrial synchronous-right ventricular; atrial synchronous-left ventricular and biventricular pacing. Optimisation of the atrioventricular and interventricular delay will be performed in the biventricular pacing group at 18 hours. The effect of biventricular pacing on myocardial injury, post operative arrhythmias and renal function will also be quantified. ClinicalTrials.gov: NCT01027299.
Lai, L P; Su, M J; Lin, J L; Tsai, C H; Lin, F Y; Chen, Y S; Hwang, J J; Huang, S K; Tseng, Y Z; Lien, W P
1999-07-01
The funny current (I(f)) contributes to phase IV spontaneous depolarization in cardiac pacemaker tissue. Enhanced I(f) activity in myocardial tissue may lead to increased automaticity and therefore tachyarrhythmia. We measured the amount of I(f) activity in the messenger ribonucleic acid (mRNA) in human atrial tissue and correlated the mRNA amount to left atrial filling pressure and atrial fibrillation (AF). A total of 34 patients undergoing open heart surgery were included (15 men and 19 women, aged 55+/-10 years). Atrial tissue was obtained from the right atrial free wall, the right atrial appendage, the left atrial free wall, and the left atrial appendage, respectively. The mRNA amount of the I(f) channel was measured by reverse transcription polymerase chain reaction and was normalized to the mRNA levels of glyceraldehyde 3-phosphate dehydrogenase. We found that the I(f) channel mRNA was present at all the atrial sampling sites. A higher left atrial filling pressure, an indicator of congestive heart failure, was associated with a higher I(f) mRNA level (r2 = 0.446, P < 0.01 by linear regression). We also found that the mRNA amount was significantly higher in patients with AF than in patients without AF (1.68+/-0.49 vs 1.27+/-0.43; P < 0.05). Age, sex, right atrial filling pressure, left atrial dimension, and left ventricular ejection fraction had no significant effect on the mRNA level. The mRNA of the I(f) channel is present in the free-wall area and appendage area from both atria. Increased left atrial filling pressure and clinical AF are associated with increased I(f) mRNA level.
Right Ventricular Outflow Tract Septal Pacing Is Superior to Right Ventricular Apical Pacing
Zou, Cao; Song, Jianping; Li, Hui; Huang, Xingmei; Liu, Yuping; Zhao, Caiming; Shi, Xin; Yang, Xiangjun
2015-01-01
Background The effects of right ventricular apical pacing (RVAP) and right ventricular outflow tract (RVOT) septal pacing on atrial and ventricular electrophysiology have not been thoroughly compared. Methods and Results To identify a more favorable pacing strategy with fewer adverse effects, 80 patients who had complete atrioventricular block with normal cardiac function and who were treated with either RVAP (n=42) or RVOT septal pacing (n=38) were recruited after an average of 2 years of follow‐up. The data from electrocardiography and echocardiography performed before pacemaker implantation and at the end of follow‐up were collected. The patients in the RVOT septal pacing and RVAP groups showed similar demographic and clinical characteristics before pacing treatments. After a mean follow‐up of 2 years, the final maximum P‐wave duration; P‐wave dispersion; Q‐, R‐, and S‐wave complex duration; left atrial volume index; left ventricular end‐systolic diameter; ratio of transmitral early diastolic filling velocity to mitral annular early diastolic velocity; and interventricular mechanical delay in the RVOT septal pacing group were significantly less than those in the RVAP group (P<0.05). The final left ventricular ejection fraction of the RVOT septal pacing group was significantly higher than that of the RVAP group (P<0.05). Conclusions Compared with RVAP, RVOT septal pacing has fewer adverse effects regarding atrial electrical activity and structure in patients with normal cardiac function. PMID:25896891
A case of atrial tachycardia treated with ivabradine as bridge to ablation.
Meles, Ester; Carbone, Claudio; Maggiolini, Stefano; Moretti, Paolo; DE Carlini, Caterina C; Gentile, Gaetano; Gnecchi-Ruscone, Tomaso
2015-05-01
Ivabradine is indicated in cardiac failure and ischemia to reduce sinus rate by inhibition of the pacemaker I(f) current in sinoatrial node. We report a case of an 18-year-old woman with left atrial tachyarrhythmia resistant to several antiarrhythmic drugs and to electric cardioversion who responded only to ivabradine, which significantly reduced heart rate without abolishing the arrhythmia itself. An ectopic focus in the ostium of left pulmonary veins was found and the patient was successfully ablated. We suggest that ivabradine might be therefore useful in the treatment of supraventricular tachyarrhythmias due to an enhanced automaticity. © 2015 Wiley Periodicals, Inc.
Cardiac arrhythmias during exercise testing in healthy men.
NASA Technical Reports Server (NTRS)
Beard, E. F.; Owen, C. A.
1973-01-01
Clinically healthy male executives who participate in a long-term physical conditioning program have demonstrated cardiac arrhythmia during and after periodic ergometric testing at submaximal and maximal levels. In 1,385 tests on 248 subjects, it was found that 34% of subjects demonstrated an arrhythmia at some time and 13% of subjects developed arrhythmia on more than one test. Premature systoles of ventricular origin were most common, but premature systoles of atrial origin, premature systoles of junctional origin, paroxysmal atrial tachycardia, atrioventricular block, wandering pacemaker, and pre-excitation were also seen. Careful post-test monitoring and pulse rate regulated training sessions are suggested for such programs.
Outcomes of cardiac pacing in adult patients after a Fontan operation.
Egbe, Alexander C; Huntley, Geoffery D; Connolly, Heidi M; Ammash, Naser M; Deshmukh, Abhishek J; Khan, Arooj R; Said, Sameh M; Akintoye, Emmanuel; Warnes, Carole A; Kapa, Suraj
2017-12-01
Cardiac pacing can be challenging after a Fontan operation, and limited data exist regarding pacing in adult Fontan patients. The objectives of our study were to determine risk factors for pacing and occurrence of device-related complications (DRCs) and pacemaker reinterventions. We performed a retrospective review of Fontan patients from 1994 through 2014. We defined DRCs as lead failure, lead recall, cardiac perforation, lead thrombus/vegetation, or device-related infection, and cardiovascular adverse events (CAEs) as venous thrombosis, stroke, death, or heart transplant. Pacemaker reintervention was defined as lead failure or recall. Of 439 patients, 166 (38%) had pacemakers implanted (79 during childhood; 87, adulthood); 114 patients (69%) received epicardial leads initially, and 52 (31%), endocardial leads. Pacing was initially atrial in 52 patients (31%); ventricular, 30 (18%); or dual chamber, 84 (51%). There were 37 reinterventions (1.9% per year) and 48 DRCs (2.4% per year). Pacemaker implantation during childhood was a risk factor for DRCs (hazard ratio, 2.01 [CI, 1.22-5.63]; P = .03). There were 70 CAEs (venous thrombosis, 5; stroke, 11; transplant, 8; and death, 46), yielding a rate of 3.5% per year. DRCs, CAEs, and reintervention rates were comparable for patients with epicardial or endocardial leads. More than one-third of adult Fontan patients referred to Mayo Clinic had pacemaker implantation. Epicardial leads were associated with high rate of pacemaker reinterventions but similar DRC rates in comparison to endocardial leads. Copyright © 2017 Elsevier Inc. All rights reserved.
Wang, Chunguo; Ye, Minhua; Lin, Jiang; Jin, Jiang; Hu, Quanteng; Zhu, Chengchu; Chen, Baofu
2018-01-01
Introduction Surgical ablation is a generally established treatment for patients with atrial fibrillation undergoing concomitant cardiac surgery. Left atrial (LA) lesion set for ablation is a simplified procedure suggested to reduce the surgery time and morbidity after procedure. The present meta-analysis aims to explore the outcomes of left atrial lesion set versus no ablative treatment in patients with AF undergoing cardiac surgery. Methods A literature research was performed in six database from their inception to July 2017, identifying all relevant randomized controlled trials (RCTs) comparing left atrial lesion set versus no ablative treatment in AF patient undergoing cardiac surgery. Data were extracted and analyzed according to predefined clinical endpoints. Results Eleven relevant RCTs were included for analysis in the present study. The prevalence of sinus rhythm in ablation group was significantly higher at discharge, 6-month and 1-year follow-up period. The morbidity including 30 day mortality, late all-cause mortality, reoperation for bleeding, permanent pacemaker implantation and neurological events were of no significant difference between two groups. Conclusions The result of our meta-analysis demonstrates that left atrial lesion set is an effective and safe surgical ablation strategy for AF patients undergoing concomitant cardiac surgery. PMID:29360851
Shenasa, Mohammad; Josephson, Mark E; Wit, Andrew L
2017-11-01
Paroxysmal atrioventricular (A-V) block is relatively rare, and due to its transient nature, it is often under recognized. It is often triggered by atrial, junctional, or ventricular premature beats, and occurs in the presence of a diseased His-Purkinje system (HPS). Here, we present a 45-year-old white male who was admitted for observation due to recurrent syncope and near-syncope, who had paroxysmal A-V block. The likely cellular electrophysiological mechanisms(s) of paroxysmal A-V block and its differential diagnosis and management are discussed. Continuous electrocardiographic monitoring was done while the patient was in the cardiac unit. Multiple episodes of paroxysmal A-V block were documented in this case. All episodes were initiated and terminated with atrial/junctional premature beats. The patient underwent permanent pacemaker implantation and has remained asymptomatic since then. Paroxysmal A-V block is rare and often causes syncope or near-syncope. Permanent pacemaker implantation is indicated according to the current guidelines. Paroxysmal A-V block occurs in the setting of diseased HPS and is bradycardia-dependent. The detailed electrophysiological mechanisms, which involve phase 4 diastolic depolarization, and differential diagnosis are discussed. © 2017 Wiley Periodicals, Inc.
[Surgical therapy of life-threatening tachycardic cardiac arrhythmias in children].
Frank, G; Schmid, C; Baumgart, D; Lowes, D; Klein, H; Kallfelz, H C
1989-05-01
Surgical techniques for tachyarrhythmias refractory to medical treatment are used with increasing frequency. Among 211 patients undergoing antiarrhythmic surgery 10 children (2 to 14 years old) were operated by electrophysiologically directed procedures. 7 patients suffered from WPW syndrome, 2 from focal atrial tachycardias and 1 from recurrent ventricular tachycardia following the repair of Fallot's tetralogy. In all cases preoperative electrophysiologic study and intraoperative mapping preceded operative ablation. Surgical treatment consisted of interruption of the bundle of Kent (3 right-sided, 2 left-sided, 3 septal), ablation of the atrial focus (1 right-sided, 1 left-sided) and right ventricular outflow tract incision. In 7 operations cryo-techniques were added. 2 children with WPW syndrome had two interventions because of tachycardia recurrences due to multiple accessory pathways. In 1 case a VVI-pacemaker was implanted postoperatively due to complete atrioventricular block. Another 2 children with prolonged postoperative bradycardia received a pacemaker prophylactically. Only the child with previous tetralogy of Fallot is still under antiarrhythmic medication while all other children are free of tachycardiac episodes. Our data confirm the efficacy of surgical treatment of tachyarrhythmias in children thereby abolishing the need for life-long antiarrhythmic medication.
Witt, Chance M; Lenz, Charles J; Shih, Henry H; Ebrille, Elisa; Rosenbaum, Andrew N; van Zyl, Martin; Aung, Htin; Manocha, Kevin K; Deshmukh, Abhishek J; Hodge, David O; Mulpuru, Siva K; Cha, Yong-Mei; Espinosa, Raul E; Asirvatham, Samuel J; Mcleod, Christopher J
2017-08-01
Cardiac pacing from the right ventricular apex is associated with detrimental long-term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long-term outcomes and lead-related complications associated with differing ventricular lead tip position. All adult patients who underwent dual-chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long-term outcomes and lead-related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005). Septal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided. © 2017 Wiley Periodicals, Inc.
Chen, Ke-ping; Xu, Geng; Wu, Shulin; Tang, Baopeng; Wang, Li; Zhang, Shu
2013-03-01
The present study was to assess the accuracy of automatic atrial and ventricular capture management (ACM and VCM) in determining pacing threshold and the performance of a second-generation automatic atrioventricular (AV) interval extension algorithm for reducing unnecessary ventricular pacing. A total of 398 patients at 32 centres who received an EnPulse dual-chamber pacing/dual-chamber adaptive rate pacing pacemaker (Medtronic, Minneapolis, MN, USA) were enrolled. The last amplitude thresholds as measured by ACM and VCM prior to the 6-month follow-up were compared with manually measured thresholds. Device diagnostics were used to evaluate ACM and VCM and the percentage of ventricular pacing with and without the AV extension algorithm. Modelling was performed to assess longevity gains relating to the use of automaticity features. Atrial and ventricular capture management performed accurately and reliably provided complete capture management in 97% of studied patients. The AV interval extension algorithm reduced the median per cent of right ventricular pacing in patients with sinus node dysfunction from 99.7 to 1.5% at 6-month follow-up and in patients with intermittent AV block (excluding persistent 3° AV block) from 99.9 to 50.2%. On the basis of validated modelling, estimated device longevity could potentially be extended by 1.9 years through the use of the capture management and AV interval extension features. Both ACM and VCM features reliably measured thresholds in nearly all patients; the AV extension algorithm significantly reduced ventricular pacing; and the use of pacemaker automaticity features potentially extends device longevity.
A pacemaker magnet check alone is sufficient for the majority of patients postpacemaker implant.
Jones, Michael A; Wong, Kelvin C K; Qureshi, Norman; Rajappan, Kim; Bashir, Yaver; Betts, Timothy R
2014-12-01
Patients postpacemaker implant can undergo a full assessment by pacing system programmer (PSP) or a magnet check. The former takes longer, but provides more detailed information; a magnet-mode assessment is faster, but provides only capture data in an asynchronous pacing mode. A magnet-mode assessment alone may be sufficient in most cases, and current clinical practice varies considerably. A retrospective single-center assessment of all pacemaker implants receiving PSP and magnet checks between September 2009 and April 2010. Patient records were reviewed. The results of PSP and magnet checks and any subsequent device-related management were noted. A total of 168 patients underwent pacemaker implantation, magnet-mode assessment, and then PSP interrogation during this period. Magnet-mode assessment revealed a problem in only one patient-failure of atrial capture, leading to subsequent atrial lead repositioning. None of the remaining 167 patients have a serious problem at PSP interrogation; six had minor issues at PSP check, none of which required repeat surgical intervention. The magnet-mode test only provides information on lead capture in an asynchronous pacing mode, which is the most essential data postoperatively. Our study has suggested that a magnet-mode assessment without PSP interrogation may be sufficient in the immediate postimplant assessment of these patients. Routine postimplant PSP interrogation is time consuming, labor intensive, and adds only minimal additional benefit to the safe management of these patients above and beyond a magnet check, coupled with informed assessment of the associated electrocardiogram/rhythm strip, clinical examination, and chest x-ray. ©2014 Wiley Periodicals, Inc.
Sharma, Parikshit S; Kaszala, Karoly; Tan, Alex Y; Koneru, Jayanthi N; Shepard, Richard; Ellenbogen, Kenneth A; Huizar, Jose F
2016-08-01
Similar to endless loop tachycardia (ELT), repetitive nonreentrant ventriculoatrial synchrony (RNRVAS) is a ventriculoatrial (VA) synchrony pacemaker-mediated arrhythmia. RNRVAS was first described in 1990 and can only occur in the presence of retrograde VA conduction and dual-chamber or cardiac resynchronization devices with tracking (P-synchronous ventricular pacing such as DDD, DDDR) or nontracking pacing modes that allow AV-sequential pacing (DDI, DDIR). RNRVAS is promoted by (1) high lower rate limit or any feature that allows rapid pacing, (2) long AV intervals, or (3) long postventricular atrial refractory period (PVARP). In contrast to ELT, RNRVAS is a less well-recognized form of pacemaker-mediated arrhythmia; thus, unlike ELT, there are no specific device algorithms to prevent, recognize, and terminate RNRVAS. However, RNRVAS has been recently shown to occur frequently. We present a series of cases, some of which were found fortuitously. Owing to its clinical implications, we propose that algorithms should be developed to prevent, identify, and terminate RNRVAS. Published by Elsevier Inc.
Cardiac Resynchronization Therapy and phase resetting of the sinoatrial node: A conjecture
NASA Astrophysics Data System (ADS)
Cantini, Federico; Varanini, Maurizio; Macerata, Alberto; Piacenti, Marcello; Morales, Maria-Aurora; Balocchi, Rita
2007-03-01
Congestive heart failure is a severe chronic disease often associated with disorders that alter the mechanisms of excitation-contraction coupling that may result in an asynchronous left ventricular motion which may further impair the ability of the failing heart to eject blood. In recent years a therapeutic approach to resynchronize the ventricles (cardiac resynchronization therapy, CRT) has been performed through the use of a pacemaker device able to provide atrial-based biventricular stimulation. Atrial lead senses the spontaneous occurrence of cells depolarization and sends the information to the generator which, in turn, after a settled delay [atrioventricular (AV) delay], sends electrical impulses to both ventricles to stimulate their synchronous contraction. Recent studies performed on heart rate behavior of chronically implanted patients at different epochs after implantation have shown that CRT can lead to sustained overall improvement of heart function with a reduction in morbidity and mortality. At this moment, however, there are no studies about CRT effects on spontaneous heart activity of chronically implanted patients. We performed an experimental study in which the electrocardiographic signal of five subjects under chronic CRT was recorded during the activity of the pacemaker programmed at different AV delays and under spontaneous cardiac activity after pacemaker deactivation. The different behavior of heart rate variability during pacemaker activity and after pacemaker deactivation suggested the hypothesis of a phase resetting mechanism induced by the pacemaker stimulus on the sinoatrial (SA) node, a phenomenon already known in literature for aggregate of cardiac cells, but still unexplored in vivo. The constraints imposed by the nature of our study (in vivo tests) made it impossible to plan an experiment to prove our hypothesis directly. We therefore considered the best attainable result would be to prove the accordance of our data to the conjecture through the use of models and physical considerations. We first used the data of literature on far-field effects of cardiac defibrillators to prove that the pacemaker impulses delivered to the two ventricles were able to induce modifications in membrane voltage at the level of the SA node. To simulate a phase resetting mechanism of the SA node, we used a Van der Pol modified model to allow the possibility of changing the refractory period and the firing frequency of the cells separately. With appropriate parameters of the model we reproduced phase response curves that can account for our experimental data. Furthermore, the simulated curves closely resemble the functional form proposed in literature for perturbed aggregate of cardiac cells. Despite the small sample of subjects investigated and the limited number of ECG recordings at different AV delays, we think we have proved the plausibility of the proposed conjecture.
Elvan, A; Wylie, K; Zipes, D P
1996-12-01
We assessed the effects of pacing-induced chronic atrial fibrillation (AF) on sinus node function, intra-atrial conduction, and atrial refractoriness. In 15 mongrel dogs (20 to 30 kg), AV nodal block was produced by radiofrequency catheter ablation, and a ventricular-inhibited (VVI) pacemaker (Minix 8330, Medtronic) was implanted and programmed to pace at 80 pulses per minute. In 11 of these dogs, right atrial endocardial pacing leads were connected to a pulse generator (Itrel 7432, Medtronic) and set at a rate of 20 Hz to induce AF. Corrected sinus node recovery time, P-wave duration, 24-hour Holter ECG to assess AF duration, maximal heart rate in response to isoproterenol (10 micrograms/min), intrinsic heart rate after administration of atropine (0.04 mg/kg) and propranolol (0.1 mg/kg), and atrial effective refractory periods (ERPs) were obtained at baseline (EPS-1) and after 2 to 6 weeks (EPS-2) of VVI pacing alone (n = 4) or VVI pacing and rapid atrial pacing (n = 11). At EPS-2, corrected sinus node recovery time and P-wave duration were prolonged, maximal heart rate and intrinsic heart rate were decreased, atrial ERPs were shortened, and the duration of AF was increased significantly compared with EPS-1. These changes partially reversed toward baseline 1 week after conversion to sinus rhythm. Sinus node function and AF inducibility observed in the control dogs that underwent ventricular pacing alone (n = 4) did not change. Pacing-induced chronic AF induces sinus node dysfunction, prolongs intra-atrial conduction time, shortens atrial refractoriness, and perpetuates AF, changes that reverse gradually after termination of AF.
Current status of the surgical treatment of atrial fibrillation.
Geha, Alexander S; Abdelhady, Khaled
2008-03-01
Atrial fibrillation (AF) affects several million patients worldwide and is associated with a number of heart conditions, particularly coronary artery disease, rheumatic heart disease, hypertension, and congestive heart failure. The treatment of AF and its complications is quite costly. Atrial fibrillation usually results from multiple macro-re-entrant circuits in the left atrium. Very frequently, particularly in association with mitral valve disease, these circuits arise from the area of the junction of the pulmonary venous endothelium and the left atrial endocardium. Pharmacological therapy is at best 50% effective. Therapeutic options for AF include antiarrhythmic drugs, cardioversion, atrioventricular (A-V) node block, pacemaker insertion, and ablative surgery. In 1987, Cox developed an effective surgical procedure to achieve ablation. Current ablative procedures include the classic cut-and-sew Maze operation or a modification of it, namely through catheter ablation, namely, cryoablation, radiofrequency ablation (dry or irrigated), and other forms of ablation (e.g., laser, microwave). These procedures will be described, along with the indications, advantages and disadvantages of each. Special emphasis on the alternative means to cutting and sewing to achieve appropriate effective atrial scars will be stressed, and our experience with these approaches in 50 patients with AF and associated cardiac lesions and their outcomes is presented.
Schnittger, I; Appleton, C P; Hatle, L K; Popp, R L
1988-01-01
The purpose of this study was to prospectively determine the incidence of diastolic mitral and tricuspid regurgitation in atrioventricular (AV) block using Doppler echocardiography. The temporal relation between mitral and tricuspid diastolic insufficiency and the diastolic murmur recorded in patients with complete heart block was also investigated. Twenty-two consecutive patients with AV block (referred to the Echo-Doppler laboratory for routine clinical studies), aged 18 to 87 years, were enrolled in the study. Eleven patients had third degree AV block and a ventricular-inhibited (VVI) pacemaker, two patients had second degree AV block, seven patients had first degree AV block, one patient had blocked premature atrial complexes and one patient had atrial flutter with 4:1 AV block. Diastolic mitral regurgitation was detected in 20 patients, and diastolic tricuspid regurgitation in 21. A mid-diastolic murmur was detected in all patients except in the three youngest. The murmur occurred before diastolic regurgitation and coincided with peak forward flow through the AV valve after atrial contraction. M-mode mitral valve echocardiograms obtained in nine patients demonstrated near closure of some portions of the mitral valve after atrial contraction. Effective closure of the valve, however, did not occur unless ventricular systole supervened. In conclusion, diastolic mitral and tricuspid regurgitation are almost universally present in patients with AV block and are associated with a diastolic murmur. The murmur coincides with forward AV valve flow. Diastolic regurgitation is silent. Effective AV valve closure is not established until ventricular systole occurs, as demonstrated by M-mode echocardiographic recording of the mitral valve.
Is there still a role for the classical Cox-Maze III?
Yap, Cheng-Hon; Prior, David; Kenny, James; Zimmet, Adam; Chao, Victor; Mooney, Donald; Yii, Michael
2006-05-01
The incidence of surgery for atrial fibrillation (AF) is rising, paralleled by an increase in the types of lesion sets and energy sources used. These alternate energy sources have simplified the surgery at the expense of increased cost of consumables. The classical Cox-Maze III is the gold standard therapy with a proven efficacy in curing AF. Our complete experience with this procedure is presented. All 28 patients undergoing the classical Cox-Maze III procedure at our institution underwent preoperative assessment and were followed prospectively. Twenty-eight patients underwent the Cox-Maze III procedure between January 2001 and May 2003. Their mean age was 65 years (range, 44-80 years). Twenty-five patients had concomitant cardiac procedures. Mean duration of AF was 8.3 years. Permanent AF was present in 82%. Mean follow-up time was 15 +/- 8 months (range, 4-30 months). There were no perioperative or late deaths, or thromboembolic events. Sixty-one per cent had early (<3 months) atrial arrhythmia. Freedom from AF at most recent clinical follow up was 93%. Freedom from late atrial arrhythmia was 82%. Freedom from late AF or atrial flutter by pacemaker interrogation or Holter assessment was 77%. Anti-arrhythmic medication use was reduced. New York Heart Association class improved from an average of 2.8 preoperatively to 1.3 postoperatively. The result of the present study shows the safety and efficacy of the classical Cox-Maze III procedure. With the advantage of proven long-term efficacy, demonstrable safety and avoidance of costly technology, the Cox-Maze III should not be discounted as a treatment option in patients because of its perceived complexity.
Efimova, Irina; Efimova, Nataliya; Chernov, Vladimir; Popov, Sergey; Lishmanov, Yuri
2012-03-01
The aim of our study was to determine if ablation and pacing improved brain perfusion (BP) and cognitive function (CF) in patients with medically refractory rapidly conducted atrial fibrillation (Med Refr RCAF). The study included 17 patients with Med Refr RCAF (average age 55.3 ± 4.5 years). All patients underwent brain single photon emission computed tomography scanning with (99m) Tc-hexamethylpropylene amine oxime and comprehensive neuropsychological testing before and after 3 months following pacemaker implantation. The BP was significantly lower in all regions in patients with Med Refr RCAF compared with the control group. The greatest BP decrease was revealed in the inferior frontal (P = 0.002) and posterior parietal (P = 0.024) brain regions. These patients showed cognitive deficit in 94%. There was a direct correlation between BP and CF parameters. Ablation followed by pacemaker implantation had a positive effect on BP and CF in all patients with Med Refr RCAF. Thus, BP increased in the right inferior frontal (P = 0.01), in the left superior frontal (P = 0.007), and in the left temporal (P = 0.005) cortex. These patients demonstrated improvements in immediate and delayed verbal memory, immediate and delayed visual memory, abstract mentation, attention, psychomotor speed, as well as in learning. Patients with atrial fibrillation and rapid ventricular rates refractory to medical treatment have marked signs of brain hypoperfusion and impaired CF. Ablation and pacing improve left ventricular systolic function, thereby increasing BP and improving CF. ©2011, The Authors. Journal compilation ©2011 Wiley Periodicals, Inc.
Cho, Min Soo; Kim, Jun; Kim, Ju Hyeon; Kim, Minsu; Lee, Ji Hyun; Hwang, You Mi; Jo, Uk; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho
2016-01-01
Persistent atrial fibrillation (PeAF) predictors after dual-chamber pacemaker (PM) implantation remain unclear. We sought to determine these predictors and establish an integrated scoring model. Data were retrospectively reviewed for 649 patients (63.8 ± 12.3 years, 48.6% male, mean CHA2DS2-VASC score 2.7 ± 2.0) undergoing dual-chamber PM implantation. PeAF was defined as documented AF on two consecutive electrocardiograms acquired ≥7 days apart. During a 7.1-year median follow-up (interquartile range 4.5-10.1 years), 67 (10.3%) patients had PeAF. Multivariable analysis showed the following independent predictors of future PeAF: ischemic stroke or transient ischemic accident history (hazard ratio [HR] 2.03, 95% confidence interval [CI] 1.03-3.50, p = 0.040), atrial fibrillation/flutter history (HR 1.80, 95% CI 1.01-3.20, p = 0.046), sinus node disease (HR 2.24, 95% CI 1.16-4.35, p = 0.016), left atrial enlargement (>45 mm, HR 2.14, 95% CI 1.26-3.63, p = 0.005), and time in automatic mode switching >1% at first follow-up interrogation (HR 2.58, 95% CI 1.51-4.42, p < 0.001). An integrated scoring model combining these predictors showed good discrimination performance at the seven-year follow-up. (C-statistic 0.716, 95% CI 0.629-0.802, p < 0.001). Significantly greater seven-year PeAF incidences were seen in patients with higher scores (2-5) than in those with lower scores (0-1) (22.8% ± 3.8% vs. 5.3% ± 1.7%, p < 0.001). In conclusion, an integrated scoring model combining clinical, echocardiographic, and electrocardiographic characteristics is useful for predicting future PeAF in patients with a dual-chamber PM.
Cho, Min Soo; Kim, Ju Hyeon; Kim, Minsu; Lee, Ji Hyun; Hwang, You Mi; Jo, Uk; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho
2016-01-01
Persistent atrial fibrillation (PeAF) predictors after dual-chamber pacemaker (PM) implantation remain unclear. We sought to determine these predictors and establish an integrated scoring model. Data were retrospectively reviewed for 649 patients (63.8 ± 12.3 years, 48.6% male, mean CHA2DS2–VASC score 2.7 ± 2.0) undergoing dual-chamber PM implantation. PeAF was defined as documented AF on two consecutive electrocardiograms acquired ≥7 days apart. During a 7.1-year median follow-up (interquartile range 4.5–10.1 years), 67 (10.3%) patients had PeAF. Multivariable analysis showed the following independent predictors of future PeAF: ischemic stroke or transient ischemic accident history (hazard ratio [HR] 2.03, 95% confidence interval [CI] 1.03–3.50, p = 0.040), atrial fibrillation/flutter history (HR 1.80, 95% CI 1.01–3.20, p = 0.046), sinus node disease (HR 2.24, 95% CI 1.16–4.35, p = 0.016), left atrial enlargement (>45 mm, HR 2.14, 95% CI 1.26–3.63, p = 0.005), and time in automatic mode switching >1% at first follow-up interrogation (HR 2.58, 95% CI 1.51–4.42, p < 0.001). An integrated scoring model combining these predictors showed good discrimination performance at the seven-year follow-up. (C-statistic 0.716, 95% CI 0.629–0.802, p < 0.001). Significantly greater seven-year PeAF incidences were seen in patients with higher scores (2–5) than in those with lower scores (0–1) (22.8% ± 3.8% vs. 5.3% ± 1.7%, p < 0.001). In conclusion, an integrated scoring model combining clinical, echocardiographic, and electrocardiographic characteristics is useful for predicting future PeAF in patients with a dual-chamber PM. PMID:27479069
Performance of a specific algorithm to minimize right ventricular pacing: A multicenter study.
Strik, Marc; Defaye, Pascal; Eschalier, Romain; Mondoly, Pierre; Frontera, Antonio; Ritter, Philippe; Haïssaguerre, Michel; Ploux, Sylvain; Ellenbogen, Kenneth A; Bordachar, Pierre
2016-06-01
In Boston Scientific dual-chamber devices, the RYTHMIQ algorithm aims to minimize right ventricular pacing. We evaluated the performance of this algorithm determining (1) the appropriateness of the switch from the AAI(R) mode with backup VVI pacing to the DDD(R) mode in case of suspected loss of atrioventricular (AV) conduction and (2) the rate of recorded pacemaker-mediated tachycardia (PMT) when AV hysteresis searches for restored AV conduction. In this multicenter study, we included 157 patients with a Boston Scientific dual-chamber device (40 pacemakers and 117 implantable cardioverter-defibrillators) without permanent AV conduction disorder and with the RYTHMIQ algorithm activated. We reviewed the last 10 remote monitoring-transmitted RYTHMIQ and PMT episodes. We analyzed 1266 episodes of switch in 142 patients (90%): 207 (16%) were appropriate and corresponded to loss of AV conduction, and 1059 (84%) were inappropriate, of which 701 (66%) were related to compensatory pause (premature atrial contraction, 7%; premature ventricular contraction, 597 (56%); or both, 27 (3%)) or to a premature ventricular contraction falling in the post-atrial pacing ventricular refractory period interval (219, 21%) and 94 (10%) were related to pacemaker dysfunction. One hundred fifty-four PMT episodes were diagnosed in 27 patients (17%). In 85 (69%) of correctly diagnosed episodes, the onset of PMT was directly related to the algorithm-related prolongation of the AV delay, promoting AV dissociation and retrograde conduction. This study highlights some of the limitations of the RYTHMIQ algorithm: high rate of inappropriate switch and high rate of induction of PMT. This may have clinical implications in terms of selection of patients and may suggest required changes in the algorithm architecture. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Ozcan, Cevher; Jahangir, Arshad; Friedman, Paul A; Munger, Thomas M; Packer, Douglas L; Hodge, David O; Hayes, David L; Gersh, Bernard J; Hammill, Stephen C; Shen, Win-Kuang
2003-07-01
Control of ventricular rate by atrioventricular node ablation and pacemaker implantation in patients with drug-refractory atrial fibrillation (AF) is associated with improved left ventricular (LV) function. The objective of this study was to determine the effect of atrioventricular node ablation on long-term survival in patients with AF and LV dysfunction. Survival was determined by the Kaplan-Meier method for 56 study patients with LV ejection fraction (EF) < or =40% who underwent atrioventricular node ablation and pacemaker implantation and 56 age- and gender-matched control patients with AF and LVEF >40%, and age- and gender-matched control subjects from Minnesota. Groups were compared using the log-rank test. In study patients (age 69 +/- 10 years; 45 men), LVEF was 26% +/- 8% and 34% +/- 13% (p <0.001) before and after ablation, respectively. During follow-up (40 +/- 23 months), 23 patients died. Observed survival was worse than that of normal subjects (p <0.001) and control patients (p = 0.005). After ablation, LVEF nearly normalized (> or =45%) in 16 study patients (29%), in whom observed survival was comparable to that of normal subjects (p = 0.37). Coronary artery disease, hyperlipidemia, chronic renal failure, previous myocardial infarction, and coronary artery operation were independent predictors for mortality. Near normalization of LVEF occurred in 29% of study patients, suggesting that AF-induced EF reduction is reversible in many patients. Normal survival in patients with reversible LV dysfunction highlights potential survival benefits of rate control. Poor survival in patients with persistent LV dysfunction confirms the importance of optimal medical therapy.
Facchin, D; Baccillieri, M S; Gasparini, G; Zoppo, F; Allocca, G; Brieda, M; Verlato, R; Proclemer, A
2016-10-01
Device follow-up is mandatory in the care of patients with a pacemaker. However, in most cases, device checks appear to be mere technical, time-consuming procedures. The aim of this research is to evaluate whether remote follow-up can replace in-clinic device checks by assessing clinical outcomes for pacemaker patients followed only via remote follow-up. Consecutive pacemaker patients followed with remote monitoring were prospectively included by 6 Italian cardiology centers in an observational investigation. The workflow for remote monitoring included an initial assessment by nursing staff and, when necessary, by a responsible physician for medical decisions. No in-person visits were scheduled after the start of remote monitoring. One-thousand and two-hundred and fifty one patients (30% female, 75±11years old) were followed for a median observation period of 15months. Out of 4965 remote transmissions, 1882 (38%) had at least one clinically relevant event to be investigated further, but, only after 137 transmissions (2.8%), the patients were contacted for an in-clinic visit or hospitalization. Sixty-nine patients died and 124 were hospitalized for various reasons. Atrial fibrillation episodes were the most common clinical events discovered by remote transmissions, occurring in 1339 (26%) transmissions and 471 (38%) patients. Our experience shows that remote monitoring in a pacemaker population can safely replace in-clinic follow-up, avoiding unnecessary in-hospital device follow-up. Copyright © 2016. Published by Elsevier Ireland Ltd.
Chudzik, Michal; Klimczak, Artur; Wranicz, Jerzy Krzysztof
2013-10-31
We sought to determine the usefulness of ambulatory 24-hour Holter monitoring in detecting asymptomatic pacemaker (PM) malfunction episodes in patients with dual-chamber pacemakers whose pacing and sensing parameters were proper, as seen in routine post-implantation follow-ups. Ambulatory 24-hour Holter recordings (HM) were performed in 100 patients with DDD pacemakers 1 day after the implantation. Only asymptomatic patients with proper pacing and sensing parameters (assessed on PM telemetry on the first day post-implantation) were enrolled in the study. The following parameters were assessed: failure to pace, failure to sense (both oversensing and undersensing episodes) as well as the percentage of all PM disturbances. Despite proper sensing and pacing parameters, HM revealed PM disturbances in 23 patients out of 100 (23%). Atrial undersensing episodes were found in 12 patients (p < 0.005) with totally 963 episodes and failure to capture in 1 patient (1%). T wave oversensing was the most common ventricular channel disorder (1316 episodes in 9 patients, p < 0.0005). Malfunction episodes occurred sporadically, leading to pauses of up to 1.6 s or temporary bradycardia, which were, nevertheless, not accompanied by clinical symptoms. No ventricular pacing disturbances were found. Asymptomatic pacemaker dysfunction may be observed in nearly 25% of patients with proper DDD parameters after implantation. Thus, ambulatory HM during the early post-implantation period may be a useful tool to detect the need to reprogram PM parameters.
Long-term effectiveness of surgical treatment of ectopic atrial tachycardia.
Prager, N A; Cox, J L; Lindsay, B D; Ferguson, T B; Osborn, J L; Cain, M E
1993-07-01
The purpose of this study was to determine the long-term clinical outcome of patients with ectopic atrial tachycardias treated surgically. Ectopic atrial tachycardia is an uncommon arrhythmia that can be symptomatic and is associated with the development of a cardiomyopathy. Management strategies are not well defined because of the paucity of data on the long-term effectiveness of pharmacologic and nonpharmacologic therapies. The long-term clinical impact of medical and surgical therapy was determined in 15 consecutive patients with ectopic atrial tachycardia. All 15 patients were initially treated with antiarrhythmic drugs (mean 5.7 +/- 2.2 drugs/patient). An effective drug regimen was identified in only 5 (33%) of the 15 patients; the remaining 10 patients were treated surgically. In each, individualized surgical procedures were guided by computer-assisted intraoperative mapping, with atrial plaques comprising up to 156 electrodes. Focal ablation was performed in four patients and atrial isolation procedures in six. The 10 patients treated surgically were followed up a mean of 4 +/- 3.2 years. Ectopic atrial tachycardia recurred in one patient. A permanent pacemaker was implanted in two patients, one of whom also required reoperation for constrictive pericarditis. There were no operative deaths. Ectopic atrial tachycardia recurred in three (60%) of the five patients discharged on antiarrhythmic drug therapy during a mean follow-up interval of 6.4 +/- 4.3 years. There was one nonarrhythmic death. Map-guided surgery demonstrated long-term efficacy in abolishing symptoms in 9 of the 10 patients with ectopic atrial tachycardia. Results demonstrate that surgery is effective for patients with ectopic atrial tachycardias who are not easily treated with antiarrhythmic drugs.
Pyloric obstruction secondary to epicardial pacemaker implantation: a case report.
Bedoya Nader, G; Kellihan, H B; Bjorling, D E; McAnulty, J
2017-02-01
A 10-year old Lhasa Apso dog was presented for an acute history of exercise intolerance and hind limb weakness. High grade second degree atrioventricular block with an atrial rate of 200 beats per minute, ventricular rate of 40 beats per minute and an intermittent ventricular escape rhythm, was diagnosed on electrocardiograph. A transdiaphragmatic, unipolar, epicardial pacemaker was implanted without immediate surgical complications. Severe vomiting was noted 12 h post-operatively. Abdominal ultrasound and a barium study supported a diagnosis of pyloric outflow obstruction and exploratory abdominal surgery was performed. The pyloric outflow tract appeared normal and no other causes of an outflow obstruction were identified. The epicardial generator was repositioned from the right to the left abdominal wall. Pyloric cell pacing was presumed to be the cause for the pyloric obstruction and severe vomiting, and this was thought to be due to close proximity of the pacemaker generator to the pylorus situated in the right abdominal wall. Repositioning of the pulse generator to the left abdominal wall resulted in resolution of vomiting. Copyright © 2016 Elsevier B.V. All rights reserved.
García Guerrero, Juan J; Fernández de la Concha Castañeda, Joaquín; Doblado Calatrava, Manuel; Redondo Méndez, Ángel; Lázaro Medrano, Manuel; Merchán Herrera, Antonio
2017-06-01
When permanent pacemaker implantation is not possible or advisable via superior venous access (i.e., axillary or subclavian veins), safe and feasible surgical alternatives are required. The femoral approach is relatively unknown and seldom studied. This single-center study analyzed 10-year outcomes of a femoral implantation approach. Data about the implantation procedure (indication, approach, lead and pacemaker models, complications), patient characteristics (age, sex, medications, comorbidities), and follow-up were analyzed for all permanent pacemaker implantations using the femoral approach between June 2001 and June 2011. A permanent pacemaker was implanted with the femoral approach in 50 patients (mean age, 76 years [range: 45-96], 31 [61%] men). The most frequent indication was atrioventricular block, associated with sinus rhythm in 30 patients and with atrial fibrillation in eight patients. Overall, 20 patients (40%) were treated with oral anticoagulants postimplantation. Mean implantation time was 64 minutes (range: 20-210) and mean fluoroscopy time was 6.7 minutes (range: 0.2-50). Minimum follow-up window was 1 year (June 2012), with a mean of 50 months [range: 1-113]). No deaths, septic episodes, or severe complications were associated with the procedure, acute or long-term. Follow-up data were available for 46 patients, of who 21 (46%) died during follow-up (mean age, 87 years [range: 73-101]). No cause of death was associated with the femoral technique. Permanent pacemaker implantation through femoral access is not difficult for an experienced implant surgeon. Outcomes were comparable to systems implanted by superior venous approach, and no severe complications were observed at 10-year follow-up. © 2017 Wiley Periodicals, Inc.
Pacemaker replacement in nonagenarians: Procedural safety and long-term follow-up.
Loirat, Aurélie; Fénéon, Damien; Behaghel, Albin; Behar, Nathalie; Le Helloco, Alain; Mabo, Philippe; Daubert, Jean-Claude; Leclercq, Christophe; Martins, Raphaël P
2015-01-01
The rate of pacemaker implantation is rising. Given that the life expectancy of the population is projected to increase, a large number of elderly patients are likely to be implanted in the future. As pacemaker batteries can last for 8-10years, an increasing number of pacemaker recipients will require replacement of their devices when they become nonagenarians. To analyse the short- and long-term outcomes after device replacement in nonagenarians. Patients aged≥90years referred to a tertiary centre for pacemaker replacement from January 2004 to July 2014 were included retrospectively. Clinical follow-up data were obtained from clinical visits or telephone interviews with patients or their families. The primary clinical endpoint was total mortality. Secondary endpoints included early and delayed procedure-related complications and predictive risk factors for total mortality. Sixty-two patients were included (mean age 93.3±2.9years at time of pacemaker replacement). Mean procedure duration was 35.7±17.2minutes. Mean hospital stay was 2.2±1.1days. One patient died from a perioperative complication. Thirty-seven patients (59.7%) died during a median follow-up of 22.1months (interquartile range, 11.8-39.8months). Survival rates were 84.2% (95% confidence interval [CI] 71.8-91.5%) at 1year, 66.9% (95% CI 51.8-78.2%) at 2years and 22.7% (95% CI 10.6-37.7%) at 5years. Atrial fibrillation (hazard ratio 2.47, 95% CI 1.1-5.6) and non-physiological pacing (i.e. VVI pacing in patients in sinus rhythm) (hazard ratio 2.20, 95% CI 1.0-4.9) were predictors of mortality. Pacemaker replacement in nonagenarians is a safe and straightforward procedure. These data suggest that procedures can be performed securely in this old and frail population, with patients living for a median of 30months afterwards. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Osztheimer, István; Szilágyi, Szabolcs; Pongor, Zsuzsanna; Zima, Endre; Molnár, Levente; Tahin, Tamás; Özcan, Emin Evren; Széplaki, Gábor; Merkely, Béla; Gellér, László
2017-06-01
Lead dislocations of pacemaker systems are reported in all and even in high-volume centers. Repeated procedures necessitated by lead dislocations are associated with an increased risk of complications. We investigated a minimal invasive method for right atrial and ventricular lead repositioning. The minimal invasive method was applied only when passive fixation leads were implanted. During the minimal invasive procedure, a steerable catheter was advanced through the femoral vein to move the distal end of the lead to the appropriate position. Retrospective data collection was conducted in all patients with minimal invasive and with conventional method, at a single center between September 2006 and December 2012. Forty-five minimal invasive lead repositionings were performed, of which eight were acutely unsuccessful and nine electrodes re-dislocated after the procedure. One hundred two leads were repositioned with opening of the pocket during the same time, including the ones with unsuccessful minimal invasive repositionings. One procedure was acutely unsuccessful in this group and four re-dislocations happened. A significant difference of success rates was noted (66.6% vs. 95.1%, p = 0.001). One complication was observed during the minimal invasive lead repositionings (left ventricular lead microdislodgement). Open-pocket procedures showed different types of complications (pneumothorax, subclavian artery puncture, pericardial effusion, hematoma, fever, device-associated infection which necessitated explantation, atrial lead dislodgement while repositioning the ventricular one, deterioration of renal function). The minimal invasive method as a first alternative is safe and feasible. In those cases when it cannot be carried out successfully, the conventional method is applicable.
Modern Perspectives on Numerical Modeling of Cardiac Pacemaker Cell
Maltsev, Victor A.; Yaniv, Yael; Maltsev, Anna V.; Stern, Michael D.; Lakatta, Edward G.
2015-01-01
Cardiac pacemaking is a complex phenomenon that is still not completely understood. Together with experimental studies, numerical modeling has been traditionally used to acquire mechanistic insights in this research area. This review summarizes the present state of numerical modeling of the cardiac pacemaker, including approaches to resolve present paradoxes and controversies. Specifically we discuss the requirement for realistic modeling to consider symmetrical importance of both intracellular and cell membrane processes (within a recent “coupled-clock” theory). Promising future developments of the complex pacemaker system models include the introduction of local calcium control, mitochondria function, and biochemical regulation of protein phosphorylation and cAMP production. Modern numerical and theoretical methods such as multi-parameter sensitivity analyses within extended populations of models and bifurcation analyses are also important for the definition of the most realistic parameters that describe a robust, yet simultaneously flexible operation of the coupled-clock pacemaker cell system. The systems approach to exploring cardiac pacemaker function will guide development of new therapies, such as biological pacemakers for treating insufficient cardiac pacemaker function that becomes especially prevalent with advancing age. PMID:24748434
Ngaage, Dumbor L; Schaff, Hartzell V; Mullany, Charles J; Sundt, Thoralf M; Dearani, Joseph A; Barnes, Sunni; Daly, Richard C; Orszulak, Thomas A
2007-01-01
The study objective was to describe the independent effect of preoperative atrial fibrillation on the outcome of coronary artery bypass grafting, including the causes of death (cardiac vs noncardiac). We analyzed the outcome of patients with preoperative atrial fibrillation who underwent on-pump coronary artery bypass grafting between 1993 and 2002 and compared them with matched controls in sinus rhythm; matching variables were age, gender, ejection fraction, and numbers of diseased coronary arteries and distal anastomoses. Direct patient follow-up focused on late complications and reinterventions, and we investigated causes for all deaths. Operative mortality (1.6% vs 1.9%, P = .79) was similar in patients with preoperative atrial fibrillation (n = 257) compared with patients in sinus rhythm (n = 269). The patients with atrial fibrillation had longer hospital stays (9 +/- 6 days vs 8 +/- 6 days, P = .0008) and a trend to more frequent early readmissions (13% vs 9%, P = .08). During follow-up (median 6.7 years, maximum 12 years), late hospital admission was more frequent in patients with atrial fibrillation (59% vs 31%, P < .0001). Risk of late mortality (all causes) in patients with atrial fibrillation was increased by 40% compared with patients in sinus rhythm (P = 0.02), and the late cardiac death rate in the atrial fibrillation group was 2.8 times that of the sinus rhythm group (P = .0004). Major adverse cardiac events occurred in 70% of patients with preoperative atrial fibrillation compared with 52% of patients in preoperative sinus rhythm (P < .0001). Subsequent rhythm-related intervention, including pacemaker implantations, was more common in the atrial fibrillation group (relative risk = 2.1, P = .0027). Uncorrected preoperative atrial fibrillation in patients undergoing coronary artery bypass grafting is associated with increased late cardiac morbidity and mortality and poor long-term survival. These data support consideration of atrial fibrillation surgery at the time of coronary artery bypass grafting.
Ragupathi, Loheetha; Johnson, Drew; Greenspon, Arnold; Frisch, Daniel; Ho, Reginald T; Pavri, Behzad B
2018-04-18
Atrioventricular (AV) block is usually due to infranodal disease and associated with a wide QRS complex; such patients often progress to complete AV block and pacemaker dependency. Uncommonly, infranodal AV block can occur within the His bundle with a narrow QRS complex. The aims of this study were to define clinical/echocardiographic characteristics of patients with AV block within the His bundle and report progression to pacemaker dependency. We retrospectively identified patients with narrow QRS complexes and documented intra-His delay or block at electrophysiology study (group A) or with electrocardiogram-documented Mobitz II AV block/paroxysmal AV block (group B). Clinical, electrophysiological, and echocardiographic variables at presentation and pacemaker parameters at the last follow-up visit were evaluated. Twenty-seven patients (19 women) were identified (mean age 64 ± 13 years; range, 38-85 years). Four patients who had <1 month of follow-up were excluded. There were 12 patients in group A and 11 in group B; 21 of 23 presented with syncope/presyncope. All patients received pacemakers: 8 single chamber and 15 dual chamber. After a median follow-up of 6.4 years, the median percentage of ventricular pacing was 1% (interquartile range 0%-4.66%). One patient developed true pacemaker dependency. Aortic and/or mitral annular calcification was present in 13 of 22 patients with available echocardiograms. Patients who present with syncope and narrow QRS complexes with intra-His delay or Mobitz II paroxysmal AV block with narrow QRS complexes rarely progress to pacemaker dependency and require infrequent pacing. This entity is more common in women, with a higher prevalence of aortic and/or mitral annular calcification. If confirmed by additional studies, single-chamber pacemaker may be sufficient. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Expression and distribution of voltage-gated ion channels in ferret sinoatrial node.
Brahmajothi, Mulugu V; Morales, Michael J; Campbell, Donald L; Steenbergen, Charles; Strauss, Harold C
2010-10-01
Spontaneous diastolic depolarization in the sinoatrial (SA) node enables it to serve as pacemaker of the heart. The variable cell morphology within the SA node predicts that ion channel expression would be heterogeneous and different from that in the atrium. To evaluate ion channel heterogeneity within the SA node, we used fluorescent in situ hybridization to examine ion channel expression in the ferret SA node region and atrial appendage. SA nodal cells were distinguished from surrounding cardiac myocytes by expression of the slow (SA node) and cardiac (surrounding tissue) forms of troponin I. Nerve cells in the sections were identified by detection of GAP-43 and cytoskeletal middle neurofilament. Transcript expression was characterized for the 4 hyperpolarization-activated cation channels, 6 voltage-gated Na(+) channels, 3 voltage-gated Ca(2+) channels, 24 voltage-gated K(+) channel α-subunits, and 3 ancillary subunits. To ensure that transcript expression was representative of protein expression, immunofluorescence was used to verify localization patterns of voltage-dependent K(+) channels. Colocalizations were performed to observe any preferential patterns. Some overlapping and nonoverlapping binding patterns were observed. Measurement of different cation channel transcripts showed heterogeneous expression with many different patterns of expression, attesting to the complexity of electrical activity in the SA node. This study provides insight into the possible role ion channel heterogeneity plays in SA node pacemaker activity.
Wilkinson, M; Giles, A; Armour, J A; Cardinal, R
1996-01-01
To investigate the effects of heart failure induced by chronic rapid ventricular pacing (six weeks) on canine atrial and ventricular muscarinic receptors. Dogs (n = 4) were fitted with a bipolar pacing electrode connected to a Medtronic pacemaker set at 240 stimuli/min. Pacing was maintained for six weeks. Tissue samples obtained from the left atrium and ventral wall of the left ventricle were frozen at -70 degrees C. Control tissue was obtained from normal dogs (n = 6) following anesthesia and thoracotomy. M2-muscarinic receptors were characterized and quantified in tissue micropunches using the hydrophilic ligand [3H] N-methyl-scopolamine (NMS). Cardiac tissue bound [3H] NMS with the specificity of an M2 subtype. Tachycardia-induced heart failure did not affect atrial muscarinic receptors but signify left ventricular myocytes (control 160.0 +/- 10.0 fmol/mg protein versus heart failure 245.0 +/- 25.0 fmol/mg protein; P < 0.01). Canine ventricular muscarinic receptors display a specificity for the M2 subtype. In contrast to previous work, tachycardia-induced heart failure was accompanied by an increase (+ 53%) in ventricular, but not atrial, M2 receptors compared with normal dogs.
Vinther, Kristina H; Tveskov, Claus; Möller, Sören; Auscher, Soren; Osmanagic, Armin; Egstrup, Kenneth
2017-06-01
Our aim was to investigate the association of premature atrial complexes and the risk of recurrent stroke or death in patients with ischemic stroke in sinus rhythm. In a prospective cohort study, we used 24-hour Holter recordings to evaluate premature atrial complexes in patients consecutively admitted with ischemic strokes. Excessive premature atrial complexes were defined as >14 premature atrial complexes per hour and 3 or more runs of premature atrial complexes per 24 hours. During follow-up, 48-hour Holter recordings were performed after 6 and 12 months. Among patients in sinus rhythm, the association of excessive premature atrial complexes and the primary end point of recurrent stroke or death were estimated in both crude and adjusted Cox proportional hazards models. We further evaluated excessive premature atrial complexes contra atrial fibrillation in relation to the primary end point. Of the 256 patients included, 89 had atrial fibrillation. Of the patients in sinus rhythm (n = 167), 31 had excessive premature atrial complexes. During a median follow-up of 32 months, 50 patients (30% of patients in sinus rhythm) had recurrent strokes (n = 20) or died (n = 30). In both crude and adjusted models, excessive premature atrial complexes were associated with the primary end point, but not with newly diagnosed atrial fibrillation. Compared with patients in atrial fibrillation, those with excessive premature atrial complexes had similarly high risks of the primary end point. In patients with ischemic stroke and sinus rhythm, excessive premature atrial complexes were associated with a higher risk of recurrent stroke or death. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Hayashi, Kentaro; Fukunaga, Masato; Yamaji, Kyohei; An, Yoshimori; Nagashima, Michio; Hiroshima, Kenichi; Ohe, Masatsugu; Makihara, Yu; Yamashita, Kennosuke; Ando, Kenji; Iwabuchi, Masashi; Goya, Masahiko
2016-01-01
The clinical efficacy of catheter ablation (CA) for paroxysmal atrial fibrillation (PAF) in patients with sick sinus syndrome (SSS) and the mechanism and predictors of recurrence are not yet completely elucidated. Of 963 consecutive patients who underwent PAF ablation during the study period, a total of 108 patients with SSS (SSS group) and 108 matched controls without SSS (non-SSS group) were followed up. During the follow-up period (mean, 32.8±17.5 months), the SSS group had significantly higher AF recurrence rate since the last procedure than the non-SSS group (26.9% vs. 12.0%; P=0.02). The SSS group had significantly higher prevalence of non-pulmonary vein (non-PV) foci than the non-SSS group (25.9% vs. 13.9%; P=0.027). On multivariate analysis congestive heart failure (HR, 13.7; 95% CI: 1.57-119; P=0.02) and non-PV foci (HR, 5.75; 95% CI: 1.69-19.6; P=0.005) were independent predictors of recurrence following CA in the SSS group. In the SSS group, 88 patients had bradycardia-tachycardia syndrome without prior permanent pacemaker implantation. Of these, 6 required pacemaker implantation because of AF and sinus pause recurrence. Patients with SSS are at higher risk of AF recurrence after CA. Non-PV foci are associated with AF recurrence following PAF with SSS.
Sławuta, Agnieszka; Kliś, Magdalena; Skoczyński, Przemysław; Bańkowski, Tomasz; Moszczyńska-Stulin, Joanna; Gajek, Jacek
2016-01-01
Patients treated for sick sinus syndrome may have interatrial conduction disorder leading to atrial fibrillation. This study was aimed to assess the influence of the atrial pacing site on interatrial and atrioventricular conduction as well as the percentage of ventricular pacing in patients with sick sinus syndrome implanted with atrioventricular pacemaker. The study population: 96 patients (58 females, 38 males) aged 74.1 ± 11.8 years were divided in two groups: Group 1 (n = 44) with right atrial appendage pacing and group 2 (n = 52) with Bachmann's area pacing. We assessed the differences in atrioventricular conduction in sinus rhythm and atrial 60 and 90 bpm pacing, P-wave duration and percentage of ventricular pacing. No differences in baseline P-wave duration in sinus rhythm between the groups (102.4 ± 17 ms vs. 104.1 ± 26 ms, p = ns.) were noted. Atrial pacing 60 bpm resulted in longer P-wave in group 1 vs. group 2 (138.3 ± 21 vs. 106.1 ± 15 ms, p < 0.01). The differences between atrioventricular conduction time during sinus rhythm and atrial pacing at 60 and 90 bpm were significantly longer in patients with right atrial appendage vs. Bachmann's pacing (44.1 ± 17 vs. 9.2 ± 7 ms p < 0.01 and 69.2 ± 31 vs. 21.4 ± 12 ms p < 0.05, respectively). The percentage of ventricular pacing was higher in group 1 (21 vs. 4%, p < 0.01). Bachmann's bundle pacing decreases interatrial and atrioventricular conduction delay. Moreover, the frequency-dependent atrioventricular conduction lengthening is much less pronounced during Bachmann's bundle pacing. Right atrial appendage pacing in sick sinus syndrome patients promotes a higher percentage of ventricular pacing.
Alamanni, Francesco; Veglia, Fabrizio; Galli, Claudia; Parolari, Alessandro; Zanobini, Marco
2015-01-01
The radiofrequency maze procedure achieves sinus rhythm in 45%–95% of patients treated for atrial fibrillation. This retrospective study evaluates mid-term results of the radiofrequency maze—performed concomitant to elective cardiac surgery—to determine sinus-rhythm predictive factors, and describes the evolution of patients' echocardiographic variables. From 2003 through 2011, 247 patients (mean age, 64 ± 9.5 yr) with structural heart disease (79.3% mitral disease) and atrial fibrillation underwent a concomitant radiofrequency modified maze procedure. Patients were monitored by 24-hour Holter at 3, 6, 12, and 24 months, then annually. Eighty-four mitral-valve patients underwent regular echocardiographic follow-up. Univariate and multivariate analysis for risk factors of maze failure were identified. The in-hospital mortality rate was 1.2%. During a median follow-up of 39.4 months, the late mortality rate was 3.6%, and pacemaker insertion was necessary in 26 patients (9.4%). Sinus rhythm was present in 63% of patients at the latest follow-up. Predictive factors for atrial fibrillation recurrence were arrhythmia duration (hazard ratio [HR]=1.296, P=0.045) and atrial fibrillation at hospital discharge (HR=2.03, P=0.019). The monopolar device favored maze success (HR=0.191, P <0.0001). Left atrial area and indexed left ventricular end-diastolic volume showed significant decrease both in sinus rhythm and atrial fibrillation patients. Early sinus rhythm conversion was associated with improved left ventricular ejection fraction. Concomitant radiofrequency maze procedure provided remarkable outcomes. Shorter preoperative atrial fibrillation duration, monopolar device use, and prompt treatment of arrhythmia recurrences increase the midterm success rate. Early sinus rhythm restoration seems to result in better left ventricular ejection fraction recovery. PMID:26413016
Han, SuYoung; Wilson, Suzanne J; Bolter, Chris P
2010-09-01
1. In an isolated right atrial preparation, an increase in right atrial pressure (RAP) produces an increase in atrial rate. This rate response is larger and occurs faster when there is background vagal or muscarinic stimulation. 2. We hypothesized that in the latter situation, an increase in RAP antagonizes the effect of muscarinic stimulation through stretch inactivation of the mechanosensitive muscarinic potassium current I(K,ACh). 3. In two groups of bath-mounted right atria isolated from male Wistar rats (control n = 12; 300 nmol/L tertiapin-Q treated (to block I(K,ACh)) n = 10), we examined the change in atrial rate when RAP was raised from 2 to 8 mmHg; oxotremorine-M (oxo-M; from 10 to 500 nmol/L) was added to incrementally activate muscarinic receptors. 4. In both control and tertiapin-Q-treated groups, oxo-M reduced atrial rate, but its effect was less ( approximately 40-50%) in the latter group (P < 0.001). In control preparations, responses to an increase in RAP became progressively larger and quicker as the concentration of oxo-M was increased, whereas in tertiapin-Q treated preparations oxo-M did not affect either the amplitude or the speed of the response (P < 0.0001 for both). 5. The results support the hypothesis that atrial stretch antagonizes muscarinic slowing by its effect on I(K,ACh). We suggest that through this mechanism, parasympathetic control of heart rate may be modulated continuously by RAP.
De Simone, Antonio; Senatore, Gaetano; Donnici, Giovanni; Turco, Pietro; Romano, Enrico; Gazzola, Carlo; Stabile, G
2007-01-01
The impact of new algorithms to consistently pace the atrium on the prevention of atrial fibrillation (AF) remains unclear. Our randomized, crossover study compared the efficacy of single- and dual-site atrial pacing, with versus without dynamic atrial overdrive pacing in preventing AF. We studied 72 patients (mean age = 69.6 +/- 6.5 years, 34 men) with sick sinus syndrome (SSS) and paroxysmal or persistent AF, who received dual-chamber pacemakers (PM) equipped with an AF prevention algorithm and two atrial leads placed in the right atrial appendage (RAA), by passive fixation, and in the coronary sinus ostium (CS), by active fixation, respectively. At implant, the patients were randomly assigned to unipolar CS versus RAA pacing. The PM was programmed in DDDR mode 1 month after implant. Each patient underwent four study phases of equal duration: (1) unipolar, single site (CS or RAA) pacing with the AF algorithm ON (atrial lower rate = 0 ppm); (2) unipolar, single site pacing with the AF algorithm OFF (atrial lower rate = 70 bpm); (3) bipolar, dual-site pacing with AF algorithm ON; (4) bipolar, dual-site pacing with the AF algorithm OFF. Among 40 patients (56%), who completed the follow-up (15 +/- 4 months) no difference was observed in the mean number of automatic mode switch (AMS) corrected for the duration of follow-up, in unipolar (5.6 +/- 22.8 vs 2.6 +/- 5.5) or bipolar mode (3.3 +/- 12.7 vs 2.1 +/- 4.9) with, respectively, the algorithm OFF or ON. With the AF prevention algorithm ON, the percentage of atrial pacing increased significantly from 78.7 +/- 22.1% to 92.4 +/- 4.9% (P < 0.001), while the average ventricular heart rate was significantly lower with the algorithm ON (62.4 +/- 17.5 vs 79.9 +/- 3 bpm (P < 0.001). The AF prevention algorithm increased the percentage of atrial pacing significantly, regardless of the atrial pulse configuration and pacing site, while maintaining a slower ventricular heart rate. It had no impact on the number of AMS in the unipolar and bipolar modes in patients with SSS.
Iwazaki, Keigo; Kojima, Toshiya; Murasawa, Takahide; Yokota, Jun; Tanimoto, Hikaru; Matsuda, Jun; Fukuma, Nobuaki; Matsubara, Takumi; Shimizu, Yu; Oguri, Gaku; Hasumi, Eriko; Kubo, Hitoshi; Chang, Kyungho; Fujiu, Katsuhito; Komuro, Issei
2018-05-30
A cardiac resynchronization therapy defibrillator (CRT-D) (Medtronic Inc. Protecta XT) was implanted in a 67-year-old man who had cardiac sarcoidosis with extremely low cardiac function. He had ventricular tachycardia which was controlled by catheter ablation, medication and pacing. The programmed mode was DDI, lower rate was 90 beats/minute, paced AV delay was 150 ms, and the noncompetitive atrial pacing (NCAP) function was programmed as 300 ms.After his admission for pneumonia and heart failure, we changed his DDI mode to a DDD mode because he had atrial tachycardia, which led to inadequate bi-ventricular pacing. After a while, there were cycle lengths which were longer than his device setting and alternately varied. We were able to avoid this phenomenon with AV delay of 120 ms and NCAP of 200 ms.NCAP is an algorithm which creates a gap above a certain period after the detection of an atrial signal during the postventricular atrial refractory period of the pacemaker. This is to prevent atrial tachycardia and repetitive non-reentrant ventriculoatrial (VA) synchrony in the presence of retrograde VA conduction. But in this case, NCAP algorithm induced much lower rate than the programmed basic lower rate. This situation produced some arrhythmias and exacerbated symptoms of heart failure. This had to be paid attention to, especially when the device was programmed at high basic heart rate.
Santarpia, Giuseppe; Passafaro, Francesco; Pasceri, Eugenia; Mongiardo, Annalisa; Curcio, Antonio; Indolfi, Ciro
2018-05-01
Inadvertent pacemaker/defibrillator lead placement into the left ventricle is an unusual cardiac device-related complication and its diagnosis is not always easy and often misunderstood. Thromboembolic events are frequently associated with this procedural complication. Percutaneous lead extraction should be performed when diagnosis is made early after device implantation while long-life oral anticoagulation is a wise option when the diagnosis is delayed and the lead is not removed. A 65-year-old man affected by dilated cardiomyopathy, previously treated with a percutaneous mitral valve repair, with 2 MitraClip devices, and later with dual chamber cardioverter/defibrillator implantation, returned in outpatient clinics 2 months after discharge for deterioration of dyspnea; transthoracic echocardiography revealed that the shock lead had been accidentally placed in the apex of the left ventricle. The unintentional lead malposition through the iatrogenic atrial septal defect and its presence into the mitral valve orifice, together with the 2 clip devices implanted, generated an acceleration of transvalvular diastolic flow, determining a moderate stenosis of the mitral valve, as well as promoting a worsening of the degree of valvular regurgitation. Oral anticoagulation therapy was started and a mechanical lead extraction was percutaneously performed. A new defibrillator lead was later appropriately positioned in the apex of the right ventricle. The patient was discharged 3 days after intervention and the follow-up, performed 1 month after discharge, was uneventful. Complex interventional procedures and implantation of multiple devices can increase procedural troubles and the risk of mechanical complications related to pacemaker/defibrillator implantation. Careful observation of the QRS complex morphology on the electrocardiogram (ECG), during paced rhythm, and the achievement of the echocardiographic examination, in the postprocedural phase, allow an early diagnosis of lead malposition.
Incidence and Time Course for Developing Heart Failure With High-Burden Right Ventricular Pacing.
Merchant, Faisal M; Hoskins, Michael H; Musat, Dan L; Prillinger, Julie B; Roberts, Gregory J; Nabutovsky, Yelena; Mittal, Suneet
2017-06-01
Although right ventricular pacing can contribute to cardiomyopathy, the impact of complete atrioventricular block (cAVB) on heart failure (HF) development in pacemaker patients has not been well characterized. We evaluated the incidence and time course for developing HF after pacemaker implantation for cAVB. A MarketScan database identified patients undergoing dual-chamber pacemaker implantation from 2008 to 2014. Patients with cAVB were identified by an atrioventricular node ablation or diagnosis of third-degree AVB. Patients with ≥1 year of continuous MarketScan enrollment before and after implant and without a previous diagnosis of HF were dichotomized into those with cAVB and without AVB. The primary end point was new HF assessed over acute (0-6 months) and chronic (6 months to 4 years) phases post-pacemaker implantation. The cohort included 6994 cAVB patients and 14 208 patients without AVB, followed for 2.35 years (interquartile range, 1.62-3.39 years). After adjustment for baseline covariates, patients with cAVB experienced an increased risk of new-onset HF in the acute phase (hazard ratio, 1.62; 95% confidence interval, 1.48-1.79; P <0.001). Although the risk of HF remained elevated among those with cAVB in the chronic phase, the effect was attenuated (hazard ratio, 1.16; 95% confidence interval, 1.08-1.25; P <0.001). After pacemaker implantation, younger patients (≤55 years of age) and those with an antecedent history of atrial fibrillation experienced the highest risk of HF associated with cAVB. Patients with a diagnosis of cAVB, and thus presumed to have a higher burden of right ventricular pacing, experienced an increased risk of new-onset HF after pacemaker implantation compared with those without AVB. Better tools are needed to identify patients at high risk of developing HF in the setting of right ventricular pacing and to determine whether these patients benefit from upfront biventricular pacing. © 2017 American Heart Association, Inc.
Giannopoulos, Georgios; Kossyvakis, Charalampos; Panagopoulou, Vasiliki; Tsiachris, Dimitrios; Doudoumis, Konstantinos; Mavri, Maria; Vrachatis, Dimitrios; Letsas, Konstantinos; Efremidis, Michael; Katsivas, Apostolos; Lekakis, John; Deftereos, Spyridon
2017-05-01
Syncope is a common problem in the elderly, and a permanent pacemaker is a therapeutic option when a bradycardic etiology is revealed. However, the benefit of pacing when no association of symptoms to bradycardia has been shown is not clear, especially in the elderly. The aim of this study was to evaluate the effect of pacing on syncope-free mortality in patients aged 80 years or older with unexplained syncope and "positive" invasive electrophysiologic testing (EPT). This was an observational study. A positive EPT for the purposes of this study was defined by at least 1 of the following: a corrected sinus node recovery time of >525 ms, a basic HV interval of >55 ms, detection of infra-Hisian block, or appearance of second-degree atrioventricular block on atrial decremental pacing at a paced cycle length of >400 ms. Among the 2435 screened patients, 228 eligible patients were identified, 145 of whom were implanted with a pacemaker. Kaplan-Meier analysis determined that time to event (syncope or death) was 50.1 months (95% confidence interval 45.4-54.8 months) with a pacemaker vs 37.8 months (95% confidence interval 31.3-44.4 months) without a pacemaker (log-rank test, P = .001). The 4-year time-dependent estimate of the rate of syncope was 12% vs 44% (P < .001) and that of any-cause death was 41% vs 56% (P = .023), respectively. The multivariable odds ratio was 0.25 (95% confidence interval 0.15-0.40) after adjustment for potential confounders. In patients with unexplained syncope and signs of sinus node dysfunction or impaired atrioventricular conduction on invasive EPT, pacemaker implantation was independently associated with longer syncope-free survival. Significant differences were also shown in the individual components of the primary outcome measure (syncope and death from any cause). Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Efficacy and safety of ablation for people with non-paroxysmal atrial fibrillation.
Nyong, Jonathan; Amit, Guy; Adler, Alma J; Owolabi, Onikepe O; Perel, Pablo; Prieto-Merino, David; Lambiase, Pier; Casas, Juan Pablo; Morillo, Carlos A
2016-11-22
The optimal rhythm management strategy for people with non-paroxysmal (persistent or long-standing persistent) atrial fibrilation is currently not well defined. Antiarrhythmic drugs have been the mainstay of therapy. But recently, in people who have not responded to antiarrhythmic drugs, the use of ablation (catheter and surgical) has emerged as an alternative to maintain sinus rhythm to avoid long-term atrial fibrillation complications. However, evidence from randomised trials about the efficacy and safety of ablation in non-paroxysmal atrial fibrillation is limited. To determine the efficacy and safety of ablation (catheter and surgical) in people with non-paroxysmal (persistent or long-standing persistent) atrial fibrillation compared to antiarrhythmic drugs. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE Ovid, Embase Ovid, conference abstracts, clinical trial registries, and Health Technology Assessment Database. We searched these databases from their inception to 1 April 2016. We used no language restrictions. We included randomised trials evaluating the effect of radiofrequency catheter ablation (RFCA) or surgical ablation compared with antiarrhythmic drugs in adults with non-paroxysmal atrial fibrillation, regardless of any concomitant underlying heart disease, with at least 12 months of follow-up. Two review authors independently selected studies and extracted data. We evaluated risk of bias using the Cochrane 'Risk of bias' tool. We calculated risk ratios (RRs) for dichotomous data with 95% confidence intervals (CIs) a using fixed-effect model when heterogeneity was low (I² <= 40%) and a random-effects model when heterogeneity was moderate or substantial (I² > 40%). Using the GRADE approach, we evaluated the quality of the evidence and used the GRADE profiler (GRADEpro) to import data from Review Manager 5 to create 'Summary of findings' tables. We included three randomised trials with 261 participants (mean age: 60 years) comparing RFCA (159 participants) to antiarrhythmic drugs (102) for non-paroxysmal atrial fibrillation. We generally assessed the included studies as having low or unclear risk of bias across multiple domains, with reported outcomes generally lacking precision due to low event rates. Evidence showed that RFCA was superior to antiarrhythmic drugs in achieving freedom from atrial arrhythmias (RR 1.84, 95% CI 1.17 to 2.88; 3 studies, 261 participants; low-quality evidence), reducing the need for cardioversion (RR 0.62, 95% CI 0.47 to 0.82; 3 studies, 261 participants; moderate-quality evidence), and reducing cardiac-related hospitalisation (RR 0.27, 95% CI 0.10 to 0.72; 2 studies, 216 participants; low-quality evidence) at 12 months follow-up. There was substantial uncertainty surrounding the effect of RFCA regarding significant bradycardia (or need for a pacemaker) (RR 0.20, 95% CI 0.02 to 1.63; 3 studies, 261 participants; low-quality evidence), periprocedural complications, and other safety outcomes (RR 0.94, 95% CI 0.16 to 5.68; 3 studies, 261 participants; very low-quality evidence). In people with non-paroxysmal atrial fibrillation, evidence suggests a superiority of RFCA to antiarrhythmic drugs in achieving freedom from atrial arrhythmias, reducing the need for cardioversion, and reducing cardiac-related hospitalisations. There was uncertainty surrounding the effect of RFCA with significant bradycardia (or need for a pacemaker), periprocedural complications, and other safety outcomes. Evidence should be interpreted with caution, as event rates were low and quality of evidence ranged from moderate to very low.
Membrane currents underlying activity in frog sinus venosus
Brown, Hilary F.; Giles, Wayne; Noble, Susan J.
1977-01-01
1. The spontaneous electrical activity of small strips of muscle from the sinus venosus region of the heart of Rana catesbeiana was investigated using the double sucrose gap technique. The voltage clamp was used to record the ionic currents underlying the pace-maker depolarization and the action potential. 2. The records of spontaneous electrical activity are very similar to those obtained from the sinus venosus using micro-electrodes. Moreover, the pace-maker activity is almost completely insensitive to tetrodotoxin (TTX) at 2·0 × 10-6 g/ml., which suggests that the pace-maker responses can be classified as primary, as opposed to follower pacing. 3. In response to short rectangular depolarizing voltage clamp pulses, only one inward current is activated. This current is almost completely insensitive to TTX but can be blocked by manganese ions. It appears, therefore, to be equivalent to the slow inward (Ca2+/Na+) current, Isi, of other cardiac tissues. The threshold for Isi is near to the maximum diastolic potential, indicating that it must be activated during the pace-maker depolarization. 4. Interruption of the normal pace-maker depolarization by rapid activation of the voltage clamp circuit reveals the time-dependent decay of outward current. This current reverses between -75 and -90 mV and, therefore, is probably carried mainly by potassium ions. 5. Outward current decay is not a simple exponential, and Hodgkin—Huxley analysis suggests that two distinct components of outward current may be present. One of these is activated in the potential range of the pace-maker depolarization and the other at more positive potentials. Both outward currents reach full, steady-state activation at about zero mV, i.e. within the `plateau' range of the sinus action potential. 6. These results are compared with other recently published voltage clamp data from the rabbit sino—atrial node. 7. A hypothesis for the generation of pace-maker activity is presented which involves (i) decay of outward current and (ii) activation of the slow inward current, Isi. PMID:303699
Hassinen, Minna; Haverinen, Jaakko; Vornanen, Matti
2017-12-01
Funny current ( I f ), formed by hyperpolarization-activated cyclic nucleotide-gated channels (HCN channels), is supposed to be crucial for the membrane clock regulating the cardiac pacemaker mechanism. We examined the presence and activity of HCN channels in the brown trout ( Salmo trutta fario ) sinoatrial (SA) pacemaker cells and their putative role in heart rate ( f H ) regulation. Six HCN transcripts (HCN1, HCN2a, HCN2ba, HCN2bb, HCN3, and HCN4) were expressed in the brown trout heart. The total HCN transcript abundance was 4.0 and 4.9 times higher in SA pacemaker tissue than in atrium and ventricle, respectively. In the SA pacemaker, HCN3 and HCN4 were the main isoforms representing 35.8 ± 2.7 and 25.0 ± 1.5%, respectively, of the total HCN transcripts. Only a small I f with a mean current density of -1.2 ± 0.37 pA/pF at -140 mV was found in 4 pacemaker cells out of 16 spontaneously beating cells examined, despite the optimization of recording conditions for I f activity. I f was not found in any of the 24 atrial myocytes and 21 ventricular myocytes examined. HCN4 coexpressed with the MinK-related peptide 1 (MiRP1) β-subunit in CHO cells generated large I f currents. In contrast, HCN3 (+MiRP1) failed to produce I f in the same expression system. Cs + (2 mM), which blocked 84 ± 12% of the native I f , reversibly reduced f H 19.2 ± 3.6% of the excised multicellular pacemaker tissue from 53 ± 5 to 44 ± 5 beats/min ( P < 0.05). However, this effect was probably due to the reduction of I Kr , which was also inhibited (63.5 ± 4.6%) by Cs + These results strongly suggest that f H regulation in the brown trout heart is largely independent on I f . Copyright © 2017 the American Physiological Society.
Surgery for atrial fibrillation.
Viganò, M; Graffigna, A; Ressia, L; Minzioni, G; Pagani, F; Aiello, M; Gazzoli, F
1996-01-01
The mechanisms of atrial fibrillation arc multiple reentry circuits spinning around the atrial surface, and these baffle any attempt to direct surgical interruption. The purpose of this article is to report the surgical experience in the treatment of isolated and concomitant atrial fibrillation at the Cardiac Surgical Institute of the University of Pavia. In cases of atrial fibrillation secondary to mitral/valve disease, surgical isolation of the left atrium at the time of mitral valve surgery can prevent atrial fibrillation from involving the right atrium, which can exert its diastolic pump function on the right ventricle. Left atrial isolation was performed on 205 patients at the time of mitral valve surgery. Atrial partitioning ("maze operation") creates straight and blind atrial alleys so that non-recentry circuits can take place. Five patients underwent this procedure. In eight-cases of atrial fibrillation secondary to atrial septal defect, the adult patients with atrial septal defect and chronic or paroxysmal atrial fibrillation underwent surgical isolation of the right atrium associated which surgical correction of the defect, in order to let sinus rhythm govern the left atrium and the ventricles. "Lone" atrial fibrillation occurs in hearts with no detectable organic disease. Bi-atrial isolation with creation of an atrial septal internodal "corridor" was performed on 14 patients. In cases of atrial fibrillation secondary to mitral valve disease, left atrial isolation was performed on 205 patients at the time of mitral valve surgery with an overall sinus rhythm recovery of 44%. In the same period, sinus rhythm was recovered and persisted in only 19% of 252 patients who underwent mitral valve replacement along (P < 0.001). Sinus rhythm was less likely to recover in patients with right atriomegaly requiring tricuspid valve annuloplasty: 59% vs 84% (P < 0.001). Restoration of the right atrial function raised the cardiac index from 2.25 +/- 0.55 1/min per m2 during atrial fibrillation to 2.54 +/- 0.58 1/min per m2, with a mean percentage increase in cardiac index of 13.5% (P < 0.00018). Atrial partitioning ("maze operation") was performed on five patients with an immediate sinus rhythm recovery of 100%, but with two patients requiring pacemaker implant. Seven out of eight patients (87.5%), with atrial fibrillation secondary to atrial septal defect, who underwent surgical isolation of the right atrium at the time of surgery were free from atrial fibrillation and without medications. 2-52 months after operation. Thirteen of 14 patients with "lone" atrial fibrillation who underwent corridor procedure remained in sinus rhythm with a sinus rhythm recovery rate of 92%. Different surgical options can be chosen for different cases of atrial fibrillation, according to the underlying cardiac disease.
Ben-Ari, Meital; Naor, Shulamit; Zeevi-Levin, Naama; Schick, Revital; Ben Jehuda, Ronen; Reiter, Irina; Raveh, Amit; Grijnevitch, Inna; Barak, Omri; Rosen, Michael R; Weissman, Amir; Binah, Ofer
2016-12-01
Previous studies proposed that throughout differentiation of human induced Pluripotent Stem Cell-derived cardiomyocytes (iPSC-CMs), only 3 types of action potentials (APs) exist: nodal-, atrial-, and ventricular-like. To investigate whether there are precisely 3 phenotypes or a continuum exists among them, we tested 2 hypotheses: (1) During culture development a cardiac precursor cell is present that-depending on age-can evolve into the 3 phenotypes. (2) The predominant pattern is early prevalence of a nodal phenotype, transient appearance of an atrial phenotype, evolution to a ventricular phenotype, and persistence of transitional phenotypes. To test these hypotheses, we (1) performed fluorescence-activated cell sorting analysis of nodal, atrial, and ventricular markers; (2) recorded APs from 280 7- to 95-day-old iPSC-CMs; and (3) analyzed AP characteristics. The major findings were as follows: (1) fluorescence-activated cell sorting analysis of 30- and 60-day-old cultures showed that an iPSC-CMs population shifts from the nodal to the atrial/ventricular phenotype while including significant transitional populations; (2) the AP population did not consist of 3 phenotypes; (3) culture aging was associated with a shift from nodal to ventricular dominance, with a transient (57-70 days) appearance of the atrial phenotype; and (4) beat rate variability was more prominent in nodal than in ventricular cardiomyocytes, while pacemaker current density increased in older cultures. From the onset of development in culture, the iPSC-CMs population includes nodal, atrial, and ventricular APs and a broad spectrum of transitional phenotypes. The most readily distinguishable phenotype is atrial, which appears only transiently yet dominates at 57-70 days of evolution. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.
Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René
2017-06-01
Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.
[The use of auto mode switching in patients with sick sinus syndrome].
Vlasínová, J
2005-01-01
At present the dual chamber pacing, originally developed for patients with AV blockades, is widely used also for patients with Sick sinus syndrome (tachycardic-bradycardic type). But these patients often cause therapeutical problems to their physicians. In these cases either antiarrhythmic therapy is necessary to prevent recurrent supraventricular tachycardias (which are cause of rapid ventricular pacing) or in the case of failure of AA therapy the pacing mode has to be changed to DDI/R, which excludes physiological VAT pacing. The Auto Mode Switching (AMS) function ensures adequate ventricular pacing rate in the time of SV arrhythmias. Effects of dual chamber pacemakers equipped with AMS were studied in a group of patients with paroxysmal atrial fibrilation and/or atrial flutter. Therapy brings effects in lower of expenses due to less frequent visits at the physician, lower rate of rehospitalizations and lower need for powerful AA therapy.
Styliadis, Ioannis H; Mantziari, Aggeliki P; Gouzoumas, Nikolaos I; Vassilikos, Vasilios P; Paraskevaidis, Stelios A; Mochlas, Sotirios T; Boufidou, Amalia I; Parcharidis, Georgios E
2008-01-01
Indications for pacing and pacing mode prescription have changed in the past decades following advances in pacemaker technology. The aim of the present study was to evaluate changes in indications for pacing and pacing modes during the years 1989-2006 in a single academic pacemaker centre in Northern Greece. Archives of permanent pacemaker implantation procedures were studied retrospectively and data from all implants, first or replacements, were retrieved. Data from 2078 procedures were found, 78.7% of which were first implantations. Patients were 54% male with mean age 72.5 years. Main indications for pacing were atrioventricular block (AVB, 45.7%), sick sinus syndrome (SSS, 32.8%), and atrial fibrillation (12.1%). Almost half (48.9%) of the AVB cases were complete AVB, while the most common types of SSS were tachy-brady syndrome (44.1%) and asystole (27.1%). Rare indications for pacing were carotid sinus syndrome (5.0%), heart failure (3.3%) and hypertrophic obstructive cardiomyopathy (1.0%). The two most frequently used pacing modes were VVI (38.5%) and DDD (25.8%). However, pacing modes have changed greatly over the years, with a marked increase in dual-chamber pacing after 1997 and a preference for rate responsive units after 2002. Biventricular systems were also used in selected patients with heart failure from 2002 on. Indications for pacing and pacing mode prescription in our centre are similar to other pacemaker registries and reflect the global trend in pacing for mimicking the physiological activity of the heart and for addressing problems other than symptomatic bradycardia.
Loeffler endocarditis: silent right ventricular myocardium!
Çetin, Süha; Heper, Gülümser; Gökhan Vural, Mustafa; Hazirolan, Tuncay
2016-07-01
We present the case of a 54-year-old male patient with Loeffler endocarditis. It is a rare disorder characterized by fibrous thickening of the endocardium leading to apical obliteration and restrictive cardiomyopathy resulting in heart failure, thromboembolic events or atrial fibrillation. To the best of our knowledge, this is the first case reporting the electrical silence of the right ventricular (RV) apex caused by fibrothrombotic thickening of this area. Under these circumstances RV apical implantation of an implantable cardioverter defibrillator (ICD) or pacemaker electrode may lead to unsuccessful stimulation of these devices.
Lou, Qing; Hansen, Brian J; Fedorenko, Olga; Csepe, Thomas A; Kalyanasundaram, Anuradha; Li, Ning; Hage, Lori T; Glukhov, Alexey V; Billman, George E; Weiss, Raul; Mohler, Peter J; Györke, Sándor; Biesiadecki, Brandon J; Carnes, Cynthia A; Fedorov, Vadim V
2014-07-22
Although sinoatrial node (SAN) dysfunction is a hallmark of human heart failure (HF), the underlying mechanisms remain poorly understood. We aimed to examine the role of adenosine in SAN dysfunction and tachy-brady arrhythmias in chronic HF. We applied multiple approaches to characterize SAN structure, SAN function, and adenosine A1 receptor expression in control (n=17) and 4-month tachypacing-induced chronic HF (n=18) dogs. Novel intramural optical mapping of coronary-perfused right atrial preparations revealed that adenosine (10 μmol/L) markedly prolonged postpacing SAN conduction time in HF by 206 ± 99 milliseconds (versus 66 ± 21 milliseconds in controls; P=0.02). Adenosine induced SAN intranodal conduction block or microreentry in 6 of 8 dogs with HF versus 0 of 7 controls (P=0.007). Adenosine-induced SAN conduction abnormalities and automaticity depression caused postpacing atrial pauses in HF versus control dogs (17.1 ± 28.9 versus 1.5 ± 1.3 seconds; P<0.001). Furthermore, 10 μmol/L adenosine shortened atrial repolarization and led to pacing-induced atrial fibrillation in 6 of 7 HF versus 0 of 7 control dogs (P=0.002). Adenosine-induced SAN dysfunction and atrial fibrillation were abolished or prevented by adenosine A1 receptor antagonists (50 μmol/L theophylline/1 μmol/L 8-cyclopentyl-1,3-dipropylxanthine). Adenosine A1 receptor protein expression was significantly upregulated during HF in the SAN (by 47 ± 19%) and surrounding atrial myocardium (by 90 ± 40%). Interstitial fibrosis was significantly increased within the SAN in HF versus control dogs (38 ± 4% versus 23 ± 4%; P<0.001). In chronic HF, adenosine A1 receptor upregulation in SAN pacemaker and atrial cardiomyocytes may increase cardiac sensitivity to adenosine. This effect may exacerbate conduction abnormalities in the structurally impaired SAN, leading to SAN dysfunction, and potentiate atrial repolarization shortening, thereby facilitating atrial fibrillation. Atrial fibrillation may further depress SAN function and lead to tachy-brady arrhythmias in HF. © 2014 American Heart Association, Inc.
Electrocardiograms with pacemakers: accuracy of computer reading.
Guglin, Maya E; Datwani, Neeta
2007-04-01
We analyzed the accuracy with which a computer algorithm reads electrocardiograms (ECGs) with electronic pacemakers (PMs). Electrocardiograms were screened for the presence of electronic pacing spikes. Computer-derived interpretations were compared with cardiologists' readings. Computer-drawn interpretations required revision by cardiologists in 61.3% of cases. In 18.4% of cases, the ECG reading algorithm failed to recognize the presence of a PM. The misinterpretation of paced beats as intrinsic beats led to multiple secondary errors, including myocardial infarctions in varying localization. The most common error in computer reading was the failure to identify an underlying rhythm. This error caused frequent misidentification of the PM type, especially when the presence of normal sinus rhythm was not recognized in a tracing with a DDD PM tracking the atrial activity. The increasing number of pacing devices, and the resulting number of ECGs with pacing spikes, mandates the refining of ECG reading algorithms. Improvement is especially needed in the recognition of the underlying rhythm, pacing spikes, and mode of pacing.
A novel intra-operative, high-resolution atrial mapping approach.
Yaksh, Ameeta; van der Does, Lisette J M E; Kik, Charles; Knops, Paul; Oei, Frans B S; van de Woestijne, Pieter C; Bekkers, Jos A; Bogers, Ad J J C; Allessie, Maurits A; de Groot, Natasja M S
2015-12-01
A new technique is demonstrated for extensive high-resolution intra-operative atrial mapping that will facilitate the localization of atrial fibrillation (AF) sources and identification of the substrate perpetuating AF. Prior to the start of extra-corporal circulation, a 8 × 24-electrode array (2-mm inter-electrode distance) is placed subsequently on all the right and left epicardial atrial sites, including Bachmann's bundle, for recording of unipolar electrograms during sinus rhythm and (induced) AF. AF is induced by high-frequency pacing at the right atrial free wall. A pacemaker wire stitched to the right atrium serves as a reference signal. The indifferent pole is connected to a steal wire fixed to subcutaneous tissue. Electrograms are recorded by a computerized mapping system and, after amplification (gain 1000), filtering (bandwidth 0.5-400 Hz), sampling (1 kHz) and analogue to digital conversion (16 bits), automatically stored on hard disk. During the mapping procedure, real-time visualization secures electrogram quality. Analysis will be performed offline. This technique was performed in 168 patients of 18 years and older, with coronary and/or structural heart disease, with or without AF, electively scheduled for cardiac surgery and a ventricular ejection fraction above 40 %. The mean duration of the entire mapping procedure including preparation time was 9 ± 2 min. Complications related to the mapping procedure during or after cardiac surgery were not observed. We introduce the first epicardial atrial mapping approach with a high resolution of ≥1728 recording sites which can be performed in a procedure time of only 9±2 mins. This mapping technique can potentially identify areas responsible for initiation and persistence of AF and hopefully can individualize both diagnosis and therapy of AF.
Atrial isomerism: a surgical experience.
Sinzobahamvya, N; Arenz, C; Brecher, A M; Urban, A E
1999-06-01
Most publications on atrial isomerism are autopsy or case reports. The authors review 41 consecutive children operated on from 1980 through to 1996 with emphasis on associated cardiac anomalies, surgical procedures and outcome. Left atrial isomerism was present in 23 patients. Interruption of the inferior vena cava (56%), atrio-ventricular septal defect (47%), common atrium (38%) and cor triatriatum sinistrum (30%) were the most common diagnoses. Biventricular repair was achieved in 17 children and total cavo-pulmonary connection in two. Three underwent staged palliation: modified Blalock-Taussig shunt for two and bidirectional Glenn anastomosis for one. The remainder received a cardiac pacemaker. One patient died early after repair. Two underwent reoperation to correct a regurgitant left atrio-ventricular valve: one of these, in another hospital, had peroperative death. Three died later. Actuarial survival rate after repair and total cavo-pulmonary connection that was stabilized after 2 years was 84%. In the 18 children with right atrial isomerism, pulmonary atresia or stenosis predominated (89%) with discordant ventriculo-arterial connection (72%), atrio-ventricular septal defect (72%), 'single' ventricle (55%) and extracardiac total anomalous pulmonary venous drainage (50%). Biventricular repair was achieved in two patients and complete Fontan circulation in eight. The other eight underwent various staged palliative procedures and correction of extracardiac total anomalous pulmonary venous drainage. Five patients died postoperatively: two in our unit after modified Blalock-Taussig shunt and total cavo-pulmonary connection, three in other hospitals after repair (n = 1) and Fontan (n = 2). Five died later. One was lost for review. Survival after repair and Fontan stabilized after 6 months at 49%. In conclusion, the cardiovascular malformations associated with left atrial isomerism can often be successfully corrected. Those accompanying right atrial isomerism usually preclude a biventricular repair, require staged palliation and carry a poor prognosis.
Pacemakers handshake synchronization mechanism of mammalian respiratory rhythmogenesis
Wittmeier, Steffen; Song, Gang; Duffin, James; Poon, Chi-Sang
2008-01-01
Inspiratory and expiratory rhythms in mammals are thought to be generated by pacemaker-like neurons in 2 discrete brainstem regions: pre-Bötzinger complex (preBötC) and parafacial respiratory group (pFRG). How these putative pacemakers or pacemaker networks may interact to set the overall respiratory rhythm in synchrony remains unclear. Here, we show that a pacemakers 2-way “handshake” process comprising pFRG excitation of the preBötC, followed by reverse inhibition and postinhibitory rebound (PIR) excitation of the pFRG and postinspiratory feedback inhibition of the preBötC, can provide a phase-locked mechanism that sequentially resets and, hence, synchronizes the inspiratory and expiratory rhythms in neonates. The order of this handshake sequence and its progression vary depending on the relative excitabilities of the preBötC vs. the pFRG and resultant modulations of the PIR in various excited and depressed states, leading to complex inspiratory and expiratory phase-resetting behaviors in neonates and adults. This parsimonious model of pacemakers synchronization and mutual entrainment replicates key experimental data in vitro and in vivo that delineate the developmental changes in respiratory rhythm from neonates to maturity, elucidating their underlying mechanisms and suggesting hypotheses for further experimental testing. Such a pacemakers handshake process with conjugate excitation–inhibition and PIR provides a reinforcing and evolutionarily advantageous fail-safe mechanism for respiratory rhythmogenesis in mammals. PMID:19008356
Schweizer, Patrick A; Darche, Fabrice F; Ullrich, Nina D; Geschwill, Pascal; Greber, Boris; Rivinius, Rasmus; Seyler, Claudia; Müller-Decker, Karin; Draguhn, Andreas; Utikal, Jochen; Koenen, Michael; Katus, Hugo A; Thomas, Dierk
2017-10-16
Human induced pluripotent stem cells (hiPSC) harbor the potential to differentiate into diverse cardiac cell types. Previous experimental efforts were primarily directed at the generation of hiPSC-derived cells with ventricular cardiomyocyte characteristics. Aiming at a straightforward approach for pacemaker cell modeling and replacement, we sought to selectively differentiate cells with nodal-type properties. hiPSC were differentiated into spontaneously beating clusters by co-culturing with visceral endoderm-like cells in a serum-free medium. Subsequent culturing in a specified fetal bovine serum (FBS)-enriched cell medium produced a pacemaker-type phenotype that was studied in detail using quantitative real-time polymerase chain reaction (qRT-PCR), immunocytochemistry, and patch-clamp electrophysiology. Further investigations comprised pharmacological stimulations and co-culturing with neonatal cardiomyocytes. hiPSC co-cultured in a serum-free medium with the visceral endoderm-like cell line END-2 produced spontaneously beating clusters after 10-12 days of culture. The pacemaker-specific genes HCN4, TBX3, and TBX18 were abundantly expressed at this early developmental stage, while levels of sarcomeric gene products remained low. We observed that working-type cardiomyogenic differentiation can be suppressed by transfer of early clusters into a FBS-enriched cell medium immediately after beating onset. After 6 weeks under these conditions, sinoatrial node (SAN) hallmark genes remained at high levels, while working-type myocardial transcripts (NKX2.5, TBX5) were low. Clusters were characterized by regular activity and robust beating rates (70-90 beats/min) and were triggered by spontaneous Ca 2+ transients recapitulating calcium clock properties of genuine pacemaker cells. They were responsive to adrenergic/cholinergic stimulation and able to pace neonatal rat ventricular myocytes in co-culture experiments. Action potential (AP) measurements of cells individualized from clusters exhibited nodal-type (63.4%) and atrial-type (36.6%) AP morphologies, while ventricular AP configurations were not observed. We provide a novel culture media-based, transgene-free approach for targeted generation of hiPSC-derived pacemaker-type cells that grow in clusters and offer the potential for disease modeling, drug testing, and individualized cell-based replacement therapy of the SAN.
Lin, Jiunn-Lee; Lai, Ling-Ping; Lin, Chih-Shen; Du, Chao-Cheng; Wu, Tsu-Juey; Chen, Shih-Ping; Lee, Wen-Chuan; Yang, Ping-Cheng; Tseng, Yung-Zu; Lien, Wen-Pin; Huang, Shoei K Stephen
2003-01-01
Interventional elimination of chronic persistent atrial fibrillation (AFib) remains difficult. An animal model mimicking the clinical situation is important. Twenty-five adult pigs were implanted with a high-speed atrial pacemaker. After continuous pacing at 600 bpm for 6 weeks, 20 (91%) of the 22 survivals developed sustained AFib lasting for at least 24 h. Epicardial dense mapping revealed multiple coexisting reentrant wavelets in the left and the right atrium (LA and RA, respectively; 10.6 +/- 2.9 vs. 7.6 +/- 2.4 wavelets/cm(2)/s; p < 0.002). The mean local A-A intervals were 87.2 +/- 14.6 ms in the LA and 103.3 +/- 19.0 ms in the RA (p < 0.0002). Acute termination of sustained AFib was successful in 3 of the 5 pigs by propafenone, but in none of the 6 by dl-sotalol. Epicardial cryothermal ablation failed to terminate any AFib by compartmentalization of the RA free wall alone (4 pigs) or together with the LA appendage (4 pigs). Electron microscopic examination demonstrated diffuse perinuclear myolysis, myofibrillar fragmentation and mitochondrial crystal disruption in the atrium. Pacing-induced sustained AFib (> or =24 h) in adult pigs is a feasible and efficient animal model with electrophysiological and histological characteristics closely similar to those seen in humans. Copyright 2003 S. Karger AG, Basel
Reiffel, James A; Camm, A John; Belardinelli, Luiz; Zeng, Dewan; Karwatowska-Prokopczuk, Ewa; Olmsted, Ann; Zareba, Wojciech; Rosero, Spencer; Kowey, Peter
2015-10-01
Atrial fibrillation (AF) requires arrhythmogenic changes in atrial ion channels/receptors and usually altered atrial structure. AF is commonly treated with antiarrhythmic drugs; the most effective block many ion channels/receptors. Modest efficacy, intolerance, and safety concerns limit current antiarrhythmic drugs. We hypothesized that combining agents with multiple anti-AF mechanisms at reduced individual drug doses might produce synergistic efficacy plus better tolerance/safety. HARMONY tested midrange ranolazine (750 mg BID) combined with 2 reduced dronedarone doses (150 mg BID and 225 mg BID; chosen to reduce dronedarone's negative inotropic effect-see text below) over 12 weeks in 134 patients with paroxysmal AF and implanted pacemakers where AF burden (AFB) could be continuously assessed. Patients were randomized double-blind to placebo, ranolazine alone (750 mg BID), dronedarone alone (225 mg BID), or one of the combinations. Neither placebo nor either drugs alone significantly reduced AFB. Conversely, ranolazine 750 mg BID/dronedarone 225 mg BID reduced AFB by 59% versus placebo (P=0.008), whereas ranolazine 750 mg BID/dronedarone 150 mg BID reduced AFB by 43% (P=0.072). Both combinations were well tolerated. HARMONY showed synergistic AFB reduction by moderate dose ranolazine plus reduced dose dronedarone, with good tolerance/safety, in the population enrolled. ClinicalTrials.gov; Unique identifier: NCT01522651. © 2015 American Heart Association, Inc.
Crandall, Mark A.; Bradley, David J.; Packer, Douglas L.; Asirvatham, Samuel J.
2009-01-01
Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Its increasing prevalence, particularly among the elderly, renders it one of the most serious current medical epidemics. Several management questions confront the clinician treating a patient with AF: Should the condition be treated? Is the patient at risk of death or serious morbidity as a result of this diagnosis? If treatment is necessary, is rate control or rhythm control superior? Which patients need anticoagulation therapy, and for how long? This review of articles obtained by a search of the PubMed and MEDLINE databases presents the available evidence that can guide the clinician in answering these questions. After discussing the merits of available therapy, including medications aimed at controlling rate, rhythm, or both, we focus on the present status of ablative therapy for AF. Catheter ablation, particularly targeting the pulmonary veins, is being increasingly performed, although the precise indications for this approach and its effectiveness and safety are being actively investigated. We briefly discuss other invasive options that are less frequently used, such as pacemakers, defibrillators, left atrial appendage closure devices, and the surgical maze procedure. PMID:19567719
3D virtual human atria: A computational platform for studying clinical atrial fibrillation
Aslanidi, Oleg V; Colman, Michael A; Stott, Jonathan; Dobrzynski, Halina; Boyett, Mark R; Holden, Arun V; Zhang, Henggui
2011-01-01
Despite a vast amount of experimental and clinical data on the underlying ionic, cellular and tissue substrates, the mechanisms of common atrial arrhythmias (such as atrial fibrillation, AF) arising from the functional interactions at the whole atria level remain unclear. Computational modelling provides a quantitative framework for integrating such multi-scale data and understanding the arrhythmogenic behaviour that emerges from the collective spatio-temporal dynamics in all parts of the heart. In this study, we have developed a multi-scale hierarchy of biophysically detailed computational models for the human atria – 3D virtual human atria. Primarily, diffusion tensor MRI reconstruction of the tissue geometry and fibre orientation in the human sinoatrial node (SAN) and surrounding atrial muscle was integrated into the 3D model of the whole atria dissected from the Visible Human dataset. The anatomical models were combined with the heterogeneous atrial action potential (AP) models, and used to simulate the AP conduction in the human atria under various conditions: SAN pacemaking and atrial activation in the normal rhythm, break-down of regular AP wave-fronts during rapid atrial pacing, and the genesis of multiple re-entrant wavelets characteristic of AF. Contributions of different properties of the tissue to the mechanisms of the normal rhythm and AF arrhythmogenesis are investigated and discussed. The 3D model of the atria itself was incorporated into the torso model to simulate the body surface ECG patterns in the normal and arrhythmic conditions. Therefore, a state-of-the-art computational platform has been developed, which can be used for studying multi-scale electrical phenomena during atrial conduction and arrhythmogenesis. Results of such simulations can be directly compared with experimental electrophysiological and endocardial mapping data, as well as clinical ECG recordings. More importantly, the virtual human atria can provide validated means for directly dissecting 3D excitation propagation processes within the atrial walls from an in vivo whole heart, which are beyond the current technical capabilities of experimental or clinical set-ups. PMID:21762716
Bhattacharyya, Pranab Jyoti; Agrawal, Shweta; Barkataky, Jogesh Chandra; Bhattacharyya, Anjan Kumar
2015-01-01
Insulation break in a permanent pacemaker lead is a rare long-term complication. We describe an elderly male with a VVIR pacemaker, who presented with an episode of presyncope more than 3 years after the initial implantation procedure, attributed to insulation break possibly caused by lead entrapment in components of the medial subclavicular musculotendinous complex (MSMC) and repeated compressive damage over time during ipsilateral arm movement requiring lead replacement. The differential diagnosis of a clinical presentation when pacing stimuli are present with failure to capture and the role of the MSMC in causing lead damage late after implantation are discussed. PMID:26995445
Investigation of mechanisms and non-pharmacological therapy of cardiac arrhythmias
NASA Astrophysics Data System (ADS)
Vago, Hajnalka
Learning of mechanisms of arrhythmias may contribute substantially to the development of effective pharmacological and non-pharmacological therapeutic methods. Clinical relevance of endothelin-1 (ET-1), a strong vasoconstrictor and arrhythmogenic endogenous substrate, is not clarified yet. In our experimental studies, performed in the in situ canine heart, electrophysiological effects and the role in the pathomechanism of malignant ventricular tachyarrhythmias of endogenous and exogenous ET-1 was investigated. It has been proven in the in vivo ischaemia-reperfusion canine heart model, that during reperfusion ET-1 and big-ET levels increase in the coronary sinus, however there was no correlation between endothelin levels and electrophysiological changes. ET A-receptor antagonist darusentan does not prevent electrophysiological changes and development of ventricular tachyarrhythmias during ischaemia and reperfusion. On the contrary, during ischaemia endogenous ET-1 tends to show balancing effect. It has been proven that administration of high dose intracoronary ET-1 bolus has dual, ischaemic and direct, electrophysiological effect. It has been shown for the first time, that ET-1 causes monophasic action potential (MAP) and T-wave alternant. Our clinical study leads to the conclusion that previous atrial fibrillation, absence of preoperative beta-blocker treatment and combined heart surgery are strong predictors of atrial fibrillation following open heart surgery. The basis of new nonpharmacological therapies is the learning of pathomechanisms of arrhythmias and in some cases heart failure, which is an arrhythmogenic substrate. In our experimental study reliable MAP measurements, suitable for investigation of arrhythmogenesis, were performed for the first time using fractally coated ablation catheters during spontaneous rate and during stimulations. It has been proven that radiofrequency ablation affects significantly MAP parameters. In Hungary, we were the first to apply effectively biatrial pacemaker and biatrial cardioverter defibrillator for the prevention of paroxysmal atrial fibrillation. In the majority of patients frequency of paroxysmal atrial fibrillation decreased significantly due to biatrial stimulation or combined pharmacological and resynchronisation therapy. Parasymphathetic cardiac neurostimulation is a promising new non-pharmacological treatment option in certain types of arrhythmias. In our clinical study we were able to stimulate cardiac parasympathetic nerves innervating atrioventricular node achieving ventricular rate control during atrial tachyarrhythmias with chronically implanted coronary sinus lead. In our study biventricular pacemakers and cardioverter defibrillators were applied successfully in the treatment of drug refractory congestive heart failure combined with inter- and/or intraventricular conduction disturbances. AV sequential left sided chronic pacing using a single lead located in the coronary sinus has not been previously reported. Left sided DDD pacing was effective chronically in the improvement of the functional stage of patient suffering from congestive heart disease combined with left bundle branch block and binodal disease. Parallel with the investigation of pathomechanism of life-threatening ventricular tachyarrhythmias and the most common, clinically relevant atrial fibrillation due to recent technical development, we were able to support nonpharmacological therapeutic modalities, gaining popularity in clinical management, with novel observations.
Yasuoka, Yoshinori; Abe, Haruhiko; Umekawa, Seiko; Katsuki, Keiko; Tanaka, Norio; Araki, Ryo; Imanaka, Takahiro; Matsutera, Ryo; Morisawa, Daisuke; Kitada, Hirokazu; Hattori, Susumu; Noda, Yoshiki; Adachi, Hidenori; Sasaki, Tatsuya; Miyatake, Kunio
2011-03-01
Interatrial septum pacing (IAS-P) decreases atrial conduction delay compared with right atrial appendage pacing (RAA-P). We evaluate the atrial contraction with strain rate of tissue Doppler imaging (TDI) during sinus activation or with IAS-P or RAA-P. Fifty-two patients with permanent pacemaker for sinus node disease were enrolled in the study. Twenty-three subjects were with IAS-P and 29 with RAA-P. The time from end-diastole to peak end-diastolic strain rate was measured and corrected with RR interval on electrocardiogram. It was defined as the time from end-diastole to peak end-diastolic strain rate (TSRc), and the balance between maximum and minimum TSRc at three sites (ΔTSRc) was compared during sinus activation and with pacing rhythm in each group. There were no significant differences observed in general characteristics and standard echocardiographic parameters except the duration of pacing P wave between the two groups. The duration was significantly shorter in the IAS-P group compared with the RAA-P group (95 ± 34 vs 138 ± 41; P = 0.001). TSRc was significantly different between sinus activation and pacing rhythm (36.3 ± 35.7 vs 61.6 ± 36.3; P = 0.003) in the RAA-P group, whereas no significant differences were observed in the IAS-P group (25.4 ± 12.1 vs 27.7 ± 14.7; NS). During the follow-up (mean 2.4 ± 0.7 years), the incidence of paroxysmal atrial fibrillation (AF) conversion to permanent AF was not significantly different between the two groups. IAS-P decreased the contraction delay on atrial TDI compared to RAA-P; however, it did not contribute to the reduction of AF incidence in the present study. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.
Wiegand, Uwe; Nuernberg, Michael; Maier, Sebastian K G; Weiss, Christian; Sancho-Tello, María-José; Hartmann, Andreas; Schuchert, Andreas; Maier, Petra; Chan, Ngai-Yin
2008-06-01
Several studies showed the beneficial effect of pacemaker implantation on cognitive performance in patients with bradycardia. But it has never been investigated if patients with chronotropic incompetence may improve their cognitive performance if treated by a rate-adaptive system reacting to mental stress in comparison to the most frequently used accelerometer-driven pacing. The randomized, single-blind, multicenter COGNITION study evaluates if closed loop stimulation (CLS) offers incremental benefit in the speed of cognitive performance and the overall well-being of elderly patients with bradycardia compared with accelerometer-based pacing. Four hundred chronotropically incompetent patients older than 55 years will be randomized 3-6 weeks after implantation to CLS or accelerometer sensor. Follow-up visits are performed after 12 and 24 months. The speed of cognitive performance, which is the underlying function influencing all other aspects of cognitive performance, will be assessed by the number connection test, a standardized psychometric test for the elderly. Secondary endpoints include patient self-assessment of different aspects of health (by visual analogue scales), quality of life (by SF-8 health survey), the incidence of atrial fibrillation (episodes lasting for longer than 24 hours), and the frequency of serious adverse events. In the ongoing COGNITION study, we aim at long-term comparison of two rate-adaptive systems, focusing on the cognitive performance of the patients, which was neglected in the past evaluation of pacemaker sensors.
Dandamudi, Sanjay; Collins, Jeremy D; Carr, James C; Mongkolwat, Pat; Rahsepar, Amir A; Tomson, Todd T; Verma, Nishant; Arora, Rishi; Chicos, Alex B; Kim, Susan S; Lin, Albert C; Passman, Rod S; Knight, Bradley P
2016-12-01
Studies reporting the safety of magnetic resonance imaging (MRI) in patients with a cardiac implantable electronic device (CIED) have mostly excluded examinations with the device in the magnet isocenter. The purpose of this study was to describe the safety of cardiac and thoracic spine MRI in patients with a CIED. The medical records of patients with a CIED who underwent a cardiac or thoracic spine MRI between January 2011 and December 2014 were reviewed. Devices were interrogated before and after imaging with reprogramming to asynchronous pacing in pacemaker-dependent patients. The clinical interpretability of the MRI and peak and average specific absorption rates (SARs, W/kg) achieved were determined. Fifty-eight patients underwent 51 cardiac and 11 thoracic spine MRI exams. Twenty-nine patients had a pacemaker and 29 had an implantable cardioverter defibrillator. Seventeen percent (n = 10) were pacemaker dependent. Fifty-one patients (89%) had non-MRI-conditional devices. There were no clinically significant changes in atrial and ventricular sensing, impedance, and threshold measurements. There were no episodes of device mode changes, arrhythmias, therapies delivered, electrical reset, or battery depletion. One study was prematurely discontinued due to a patient complaint of chest pain of which the etiology was not determined. Across all examinations, the average peak SAR was 2.0 ± 0.85 W/kg with an average SAR of 0.35 ± 0.37 W/kg. Artifact significantly limiting the clinical interpretation of the study was present in 33% of cardiac MRI studies. When a comprehensive CIED magnetic resonance safety protocol is followed, the risk of performing 1.5-T magnetic resonance studies with the device in the magnet isocenter, including in patients who are pacemaker dependent, is low. Copyright © 2016. Published by Elsevier Inc.
Biofilm on artificial pacemaker: fiction or reality?
Santos, Ana Paula Azevedo; Watanabe, Evandro; Andrade, Denise de
2011-11-01
Cardiac pacing through cardiac pacemaker is one of the most promising alternatives in the treatment of arrhythmias, but it can cause reactions natural or complex reactions, either early or late. This study aimed to describe the scientific evidence on the risk of infection and biofilm formation associated with cardiac pacemaker. This is a study of integrative literature review. It included 14 publications classified into three thematic categories: diagnosis (microbiological and/or clinical), complications and therapy of infections. Staphylococcus epidermidis and Staphylococcus aureus were the microorganisms most frequently isolated. It was not possible to determine the incidence of infection associated with pacemakers, since the studies were generally of prevalence. In terms of therapy, the complete removal of pacemakers stood out, especially in cases of suspected biofilm. Still controversial is the use of systemic antibiotic prophylaxis in reducing the incidence of infection associated with implantation of a pacemaker.
Direct His bundle pacing post AVN ablation.
Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar
2009-08-01
Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.
DDD pacemaker for severe heart failure-alternate to CRT.
Krishnamani, N C
Patients with severe systolic Heart Failure continue to have poor quality of life and increased mortality in spite of optimal medical management. Cardiac Resynchronization Therapy [CRT] is promising modality in patients with systolic heart failure and electrocardiographic [ECG] evidence of left bundle branch block [LBBB]. Cost issues continue to elude many deserving cases of this therapy in our society. Relatively cost effective Dual chamber pacing [DDD] with right atrial and isolated left ventricular pacing [RA-LV] can be a good alternative. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Chevalier, Marc; Toporikova, Natalia; Simmers, John; Thoby-Brisson, Muriel
2016-01-01
Breathing is a vital rhythmic behavior generated by hindbrain neuronal circuitry, including the preBötzinger complex network (preBötC) that controls inspiration. The emergence of preBötC network activity during prenatal development has been described, but little is known regarding inspiratory neurons expressing pacemaker properties at embryonic stages. Here, we combined calcium imaging and electrophysiological recordings in mouse embryo brainstem slices together with computational modeling to reveal the existence of heterogeneous pacemaker oscillatory properties relying on distinct combinations of burst-generating INaP and ICAN conductances. The respective proportion of the different inspiratory pacemaker subtypes changes during prenatal development. Concomitantly, network rhythmogenesis switches from a purely INaP/ICAN-dependent mechanism at E16.5 to a combined pacemaker/network-driven process at E18.5. Our results provide the first description of pacemaker bursting properties in embryonic preBötC neurons and indicate that network rhythmogenesis undergoes important changes during prenatal development through alterations in both circuit properties and the biophysical characteristics of pacemaker neurons. DOI: http://dx.doi.org/10.7554/eLife.16125.001 PMID:27434668
Toff, W D; Edhag, O K; Camm, A J
1992-12-01
Certain applicants with stable disturbances of rhythm or conduction requiring cardiac pacing, in whom no other disqualifying condition is present, may be considered fit for medical certification restricted to multi-crew operations. The reliability of modern pacing systems appears adequate to permit restricted certification even in pacemaker dependent subjects except for certain models of pacemakers and leads known to be at increased risk of failure. These are to be avoided. There is little evidence to suggest that newer devices are any more reliable than their predecessors. Single and dual chamber systems appear to have similar reliability up to 4 years, after which time significant attrition of dual chamber devices occurs, principally due to battery depletion. All devices require increased scrutiny as they approach their end of life as predicted from longevity data and pacing characteristics. Unipolar and bipolar leads are of similar reliability, apart from a number of specific bipolar polyurethane leads which have been identified. Atrial leads, particularly those without active fixation, are less secure than ventricular leads and applicants who are dependent on atrial sensing or pacing should be denied certification. Bipolar leads are to be preferred due to the lower risk of myopotential and exogenous EMI. Sensor-driven adaptive-rate pacing systems using active sensors may have reduced longevity and require close scrutiny. Activity-sensing devices using piezoelectric crystal sensors may be subject to significant rate rises in rotary wing aircraft. The impracticality of restricted certification in helicopters will, in any event, preclude certification. Such devices would best be avoided in hovercraft (air cushioned vehicle) pilots. Only minor rate rises are likely in fixed-wing aircraft which are unlikely to be of significance. Anti-tachycardia devices and implanted defibrillators are inconsistent with any form of certification to fly.
Liao, Jo-Nan; Chao, Tze-Fan; Tuan, Ta-Chuan; Kong, Chi-Woon; Chen, Shih-Ann
2016-08-01
A permanent pacemaker (PPM) with dual chamber pacing (DDD) offers atrioventricular synchronization for patients with atrioventricular block (AVB). Single lead atrial synchronous ventricular pacing mode (VDD) is an alternative, but there are concerns about its efficacy and risk of atrial undersensing. Whether VDD can be a good alternative in patients with AVB remains unknown. The aim of the present study was to compare the long-term risk of mortality of VDD with DDD pacing.A total of 207 patients undergoing PPM implantations for AVB with VDD mode were enrolled from 2000 to 2013. Another 828 age- and sex-matched patients undergoing DDD implantations during the same period of time were selected as the control group in a 1 to 4 ratio. The study endpoint was mortality.A total of 1035 patients (64.3% male) were followed up for 46.5 ± 43.2 months. The mean ages were 75.0 years for VDD, and 74.9 years for DDD. The Kaplan-Meier survival analysis showed no significant difference in long-term survival between the VDD and DDD groups (log-rank P = 0.313). After adjustment for baseline characteristics, the VDD and DDD groups had a similar long-term prognosis with an adjusted hazard ratio of 0.875 (P = 0.445). Further analyses for the risk of cardiovascular and noncardiovascular deaths also showed no significant differences between the 2 groups.The long-term prognosis of VDD mode is comparable to that of DDD mode. Single lead VDD can be considered as an alternative choice in patients with AVB without sinus nodal dysfunction.
Long-term outcome in patients receiving permanent pacemaker implantation for atrioventricular block
Liao, Jo-Nan; Chao, Tze-Fan; Tuan, Ta-Chuan; Kong, Chi-Woon; Chen, Shih-Ann
2016-01-01
Abstract A permanent pacemaker (PPM) with dual chamber pacing (DDD) offers atrioventricular synchronization for patients with atrioventricular block (AVB). Single lead atrial synchronous ventricular pacing mode (VDD) is an alternative, but there are concerns about its efficacy and risk of atrial undersensing. Whether VDD can be a good alternative in patients with AVB remains unknown. The aim of the present study was to compare the long-term risk of mortality of VDD with DDD pacing. A total of 207 patients undergoing PPM implantations for AVB with VDD mode were enrolled from 2000 to 2013. Another 828 age- and sex-matched patients undergoing DDD implantations during the same period of time were selected as the control group in a 1 to 4 ratio. The study endpoint was mortality. A total of 1035 patients (64.3% male) were followed up for 46.5 ± 43.2 months. The mean ages were 75.0 years for VDD, and 74.9 years for DDD. The Kaplan–Meier survival analysis showed no significant difference in long-term survival between the VDD and DDD groups (log-rank P = 0.313). After adjustment for baseline characteristics, the VDD and DDD groups had a similar long-term prognosis with an adjusted hazard ratio of 0.875 (P = 0.445). Further analyses for the risk of cardiovascular and noncardiovascular deaths also showed no significant differences between the 2 groups. The long-term prognosis of VDD mode is comparable to that of DDD mode. Single lead VDD can be considered as an alternative choice in patients with AVB without sinus nodal dysfunction. PMID:27583889
Kiuchi, Márcio G; Chen, Shaojie; E Silva, Gustavo R; Paz, Luis M R; Kiuchi, Tetsuaki; de Paula Filho, Ary G; Souto, Gladyston L L
2016-12-01
Atrial fibrillation (AF) commonly occurs in association with chronic kidney disease (CKD), resulting in adverse outcomes. Combining pulmonary vein isolation (PVI) and renal sympathetic denervation (RSD) may reduce the recurrence of AF in patients with CKD and hypertension. We considered that RSD could reduce the recurrence of AF in patients with CKD by modulating sympathetic hyperactivity. Our goal was to compare the impact of PVI + RSD with that of PVI alone in patients with concurrent AF and CKD. This was a single-center, prospective, longitudinal, randomized, double-blind study. Forty-five patients with controlled hypertension, symptomatic paroxysmal AF and/or persistent AF, stage 2 or 3 CKD, and a dual-chamber pacemaker were enrolled from January 2014 to January 2015. We assessed the 30-second recurrence of AF recorded by the pacemaker, 24-hour ambulatory blood pressure measurements, estimated glomerular filtration rate, albuminuria, echocardiographic parameters, and safety of RSD. No patient developed procedural or other complications. The ambulatory blood pressure measurements did not differ within the PVI + RSD group or between the PVI + RSD and PVI groups throughout the study. Significantly more patients in the PVI + RSD group than in the PVI group were free of AF at the 12-month follow-up evaluation. The PVI group had an unacceptable response to ablation with respect to changes in echocardiographic parameters, whereas these parameters improved in the PVI + RSD group. PVI + RSD were associated with a lower AF recurrence rate than PVI alone; it also improved renal function and some echocardiographic parameters. These encouraging data will serve as baseline information for further long-term studies on larger patient populations.
Long-term outcomes following high intensity focused ultrasound ablation for atrial fibrillation.
Davies, Edward J; Bazerbashi, Samer; Asopa, Sanjay; Haywood, Guy; Dalrymple-Hay, Malcolm
2014-01-01
The aim of this study is to assess the safety and efficacy of the Epicor high intensity focused ultrasound (St. Jude, Inc.®, Minneapolis, MN, USA) system using seven-day ambulatory electrocardiogram (ECG) monitoring over a two-year follow-up period. One hundred and ten patients undergoing ablation were included from a single center between January 2006 and December 2009. Rhythm was assessed using seven-day ambulatory ECG or permanent pacemaker interrogation. Seventeen patients were lost to follow-up, seven through death. Results were reported according to atrial fibrillation (AF) class preoperatively: paroxysmal, persistent, and long-standing persistent (LSP). Forty-nine percent of patients remained in sinus rhythm at greater than two years. The percentage of patients in sinus rhythm according to preoperative AF class were 81% (paroxysmal AF), 56% (persistent AF), and 18% (long-standing AF). The class of AF prior to surgery, left atrium size, and body mass index determined the long-term outcome. There were no procedure-related complications. We conclude that high intensity focused ultrasound ablation for atrial fibrillation using the Epicor system is safe and effective for surgical patients with paroxysmal AF. The persistent and LSP AF results suggest that alternative ablation strategies should be considered for these patients. © 2013 Wiley Periodicals, Inc.
Complications of pacemaker therapy in adults with congenital heart disease: a multicenter study.
Opić, Petra; van Kranenburg, Matthijs; Yap, Sing-Chien; van Dijk, Arie P; Budts, Werner; Vliegen, Hubert W; van Erven, Lieselot; Can, Anil; Sahin, Gulhan; Theuns, Dominic A M J; Witsenburg, Maarten; Roos-Hesselink, Jolien W
2013-10-09
This study aims to investigate indications and complications of permanent cardiac pacing in adults with congenital heart disease (CHD). Two-hundred and seventy-four CHD patients were identified who underwent permanent pacemaker implantation between 1972 and 2009. The indication for pacing was acquired sinus node or AV node conduction disease (63%), sinus node or AV node conduction disease after cardiac surgery (28%), and drug/arrhythmia-related indications (9%). Patients with complex CHD received a pacemaker at younger age (23 versus 31 years, p<0.0001) and more often received an epicardial pacing system (51% versus 23%, p<0.0001) compared to those with simple or moderate CHD. Twenty-nine patients (10.6%) had a periprocedural complication during the primary pacemaker implantation (general population: 5.2%). The most common acute complications were lead dysfunction (4.0%), bleeding (2.6%), pocket infection (1.5%) and pneumothorax (1.5%). During a median follow-up of 12 years, pacemaker-related complications requiring intervention occurred in 95 patients (34.6%). The most common late pacemaker-related complications included lead failure (24.8%), pacemaker dysfunction/early battery depletion (5.1%), pacemaker migration (4.7%) and erosion (4.7%). Pacemaker implantation at younger age (<18 years) was an independent predictor of late pacemaker-related complication (adjusted hazard ratio 1.68, 95% confidence interval 1.07 to 2.63, p=0.023). The risk of periprocedural complications seems higher in the CHD population compared to the general population and more than one-third of CHD patients encountered a pacemaker-related complication during long-term follow-up. This risk increases for those who receive a pacemaker at younger age. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.
Al-Wakeel, Nadya; O h-Ici, Darach; Schmitt, Katharina R; Messroghli, Daniel R; Riesenkampff, Eugénie; Berger, Felix; Kuehne, Titus; Peters, Bjoern
2016-02-01
In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems. Material and methods CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale. A total of nine patients with CHD (mean age 34.0 years, range 19.5-53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients. Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.
3D virtual human atria: A computational platform for studying clinical atrial fibrillation.
Aslanidi, Oleg V; Colman, Michael A; Stott, Jonathan; Dobrzynski, Halina; Boyett, Mark R; Holden, Arun V; Zhang, Henggui
2011-10-01
Despite a vast amount of experimental and clinical data on the underlying ionic, cellular and tissue substrates, the mechanisms of common atrial arrhythmias (such as atrial fibrillation, AF) arising from the functional interactions at the whole atria level remain unclear. Computational modelling provides a quantitative framework for integrating such multi-scale data and understanding the arrhythmogenic behaviour that emerges from the collective spatio-temporal dynamics in all parts of the heart. In this study, we have developed a multi-scale hierarchy of biophysically detailed computational models for the human atria--the 3D virtual human atria. Primarily, diffusion tensor MRI reconstruction of the tissue geometry and fibre orientation in the human sinoatrial node (SAN) and surrounding atrial muscle was integrated into the 3D model of the whole atria dissected from the Visible Human dataset. The anatomical models were combined with the heterogeneous atrial action potential (AP) models, and used to simulate the AP conduction in the human atria under various conditions: SAN pacemaking and atrial activation in the normal rhythm, break-down of regular AP wave-fronts during rapid atrial pacing, and the genesis of multiple re-entrant wavelets characteristic of AF. Contributions of different properties of the tissue to mechanisms of the normal rhythm and arrhythmogenesis were investigated. Primarily, the simulations showed that tissue heterogeneity caused the break-down of the normal AP wave-fronts at rapid pacing rates, which initiated a pair of re-entrant spiral waves; and tissue anisotropy resulted in a further break-down of the spiral waves into multiple meandering wavelets characteristic of AF. The 3D virtual atria model itself was incorporated into the torso model to simulate the body surface ECG patterns in the normal and arrhythmic conditions. Therefore, a state-of-the-art computational platform has been developed, which can be used for studying multi-scale electrical phenomena during atrial conduction and AF arrhythmogenesis. Results of such simulations can be directly compared with electrophysiological and endocardial mapping data, as well as clinical ECG recordings. The virtual human atria can provide in-depth insights into 3D excitation propagation processes within atrial walls of a whole heart in vivo, which is beyond the current technical capabilities of experimental or clinical set-ups. Copyright © 2011 Elsevier Ltd. All rights reserved.
[Auricular arrhythmia in Steinert's myotonia. Apropos of a case with a familial study].
Chagnon, A; Vidal, M E
1983-02-24
A case of bradycardia-tachycardia syndrome leading to the late discovery of Steinert syndrome is reported. There is a discrepancy between the frequency of the main features of the bradycardia-tachycardia syndrome (sinoatrial block and atrial flutter in our observation) usually reported in Steinert disease and the fact that no case similar to ours seems to have yet been reported; this suggests definite underrating. Insertion of a pacemaker should avoid sudden death from a conduction disturbance. The heart should be carefully monitored in patients with myotonic dystrophy; conversely, this diagnosis should be considered in the etiologic diagnosis of myocardiopathies.
Fontan completion in patients with atrial isomerism and separate hepatic venous drainage.
Nakata, Tomohiro; Fujimoto, Yoshifumi; Hirose, Keiichi; Osaki, Masaki; Tosaka, Yuko; Ide, Yujiro; Tachi, Maiko; Sakamoto, Kisaburo
2010-06-01
Fontan completion in patients with atrial isomerism, in which the inferior vena cava (IVC) and the hepatic vein (HV) drain separately, is technically challenging. Herein, we review our surgical approach to these patients. The medical records of 50 consecutive patients with atrial isomerism who underwent Fontan completion between 1998 and 2008 were reviewed retrospectively. Separate HV drainage was present in 17 patients. Patients with interrupted IVC were excluded. Patient characteristics were as follows: median age, 26 months (range 15-149); median weight, 9.6 kg (range 8.1-47.2); right atrial isomerism, 16 patients; and left atrial isomerism, one. The IVC and the separate HV at the level of diaphragm were contralateral in 16 patients, and ipsilateral in one. The surgical procedures for directing blood flow from the IVC and the separate HV to the pulmonary arteries were as follows: en bloc resection of the IVC and the HV and anastomosing these veins to an extracardiac conduit in 10 patients; connecting the IVC to the HV in a side-to-side fashion before anastomosing them to an extracardiac conduit in one; and lateral tunnel in another. When the IVC and the HV were widely separated by the vertebrae, we chose an intra-extracardiac conduit (intra-atrial septation) in four patients and an extracardiac conduit for the IVC and the right HV and lateral tunnel for the separate left HV in one. There was no mortality. Five re-operations were performed (pacemaker in two patients; one each of fenestration, release of outflow obstruction and ligation of collateral arteries). Sixteen patients underwent follow-up catheterisation, which revealed central venous pressure of 12.0 + or - 2.0 mmHg and arterial oxygen saturation of 92% + or - 6%. The mid-term results of the Fontan completion in patients with atrial isomerism and separate HV drainage were excellent. The distance between the IVC and the separate HV and the position of the vertebrae should be considered when choosing a surgical technique. Copyright 2010. Published by Elsevier B.V.
Marchandise, Sébastien; Scavée, Christophe; le Polain de Waroux, Jean-Benoit; de Meester, Christophe; Vanoverschelde, Jean-Louis; Debbas, Nadia
2012-04-01
This prospective non-randomized single-centre registry compared clinical outcome, pacing parameters, and long-term survival in patients receiving VDD or DDD pacemaker (PMs) for symptomatic atrioventricular (AV) block. Single-lead VDD (n= 166) and DDD (n= 254) PMs were implanted in 420 successive patients with isolated AV block between January 2001 and December 2009. At the end of the follow-up period [median 25 (1-141) months], there was no difference in the incidence of atrial fibrillation [11.2% in the VDD group; 11.4% in the DDD group (P= 0.95)], myocardial infarction [31.1% in the VDD group; 25.2% in the DDD group (P= 0.20)], or dilated cardiomyopathy [9.9% in the VDD group; 8.9% in the DDD group (P= 0.74)]. At last follow-up, 65.9% of the VDD PMs and 89.3% of the DDD PMs were still programmed in their original mode with good atrial sensing. Due to permanent atrial fibrillation, 7.9% patients out of the VDD group had been switched to VVIR mode and 8.7% patients out of the DDD group to VVIR or DDIR mode. The P-wave amplitude was poor (sensed P-wave <0.5 mV) in 19.1% of the VDD PM and 1.6% of the DDD PM (P< 0.001) and 7.1% of the VDD patients and 0.4% of the DDD patients had been switched to VVIR pacing mode due to P-wave undersensing and AV dissociation (P= 0.003). Symptomatic atrial undersensing requiring upgrading was similar in both groups. The overall survival, adjusted for age, was not significantly different in the VDD and the DDD group (log rank: 0.26). Moreover, Cox survival analysis excluded the pacing mode as a significant predictor of mortality [hazard ratio (HR) = 0.79, confidence interval (CI) (0.46-1.35), P= 0.39]. Comparing VDD and DDD pacing, a significantly larger number of VDD-paced patients developed poor atrial signal detection without clinical impact. However, atrial under sensing did not influence the incidence of atrial fibrillation, myocardial infarction, dilated cardiomyopathy, or mortality.
Pacemakers and implantable cardioverter-defibrillators in pediatric patients.
Silka, Michael J; Bar-Cohen, Yaniv
2006-11-01
The use of pacemakers and implantable cardioverter-defibrillators (ICDs) in infants, children, and patients with congenital heart disease presents unique challenges and considerations. They include uncommon indications for device implantation, innovative approaches to lead implantation and configuration, and age-dependent and disease-specific aspects of device programming. In this review, the current indications for pacemaker and ICD implantation in young patients are discussed, followed by consideration of the approaches to lead and device placement in very small patients and those with complex congenital heart disease, in whom unique problems may be encountered. The limitations of programmability of current pacemakers and ICDs when used in young patients are discussed, followed by an analysis of long-term device follow-up and potential late complications.
Reyes, Guillermo; Ruyra, Xavier; Valderrama, Francisco; Jimenez, Antonio; Duran, Dario; Perez, Enrique; Daroca, Tomas; Moya, Javier; Ramirez, Ulises; Aldamiz, Gonzalo
2016-10-01
A National Spanish Registry to compile all patients treated with high intensity focused ultrasound (HIFU) energy for atrial fibrillation (AF) was created to evaluate the safety and efficacy of AF surgical ablation. A national Spanish registry was created, and ten hospitals using HIFU to ablate AF joined it. A total of 412 patients undergoing cardiac surgery between 2006 and February 2013 were included. AF was divided between paroxysmal AF (33%) and persistent AF (67%) with a mean AF duration of 29.3±108.2 months. Mean left atrial diameter was 51.2±6.5 mm. Mean underlying heart disease were aortic valve disease (49.3%), ischemic disease (25.2%) and mitral disease (33.2%) Clinical follow-up of patients and a 6 months postoperative echocardiogram were performed in all patients. A pacemaker implantation was needed in 4.9% of patients with a perioperative stroke in 2.5%. Rhythm at discharge from hospital was sinus rhythm in 58%, AF in 35.9% and atrial flutter in 0.8% of patients. Sinus rhythm restoration at 6, 12, 24 and 36 months follow-up was achieved in 66.1%, 63.8%, 63.9% and 45.9% of patients respectively. Multivariate analysis showed paroxysmal AF and sinus rhythm restoration in the operating theatre as factors related to sinus rhythm long term restoration. The Spanish national registry showed an efficacy of AF ablation with the HIFU Epicor system of 66.1%, 63.8%, 63.9% and 45.9% at 6, 12, 24 and 36 months follow-up. There were no device-related complications.
A clinical comparison between a new dual-chamber pacing mode-AAIsafeR and DDD mode.
Xue-Jun, Ren; Zhihong, Han; Ye, Wang; Huifeng, Du; Jinrong, Zhang; Fang, Chen; Jihong, Guo
2010-02-01
The aim of this study was to compare the cross-follow-up results in DDD or AAISafeR mode and to describe the safety and effectiveness of this pacing mode. The Symphony 2450/2550 cardiac pacemakers were implanted in 30 patients with sick sinus syndrome between February 2006 and September 2006. They were randomized to the DDD mode or AAISafeR mode for 3 months and then crossed over to the alternate pacing modality for an additional 3 months. No AAISafeR-related adverse event was observed. All documented episodes of paroxysmal atrial ventricular block caused the immediate switch of the pacing mode from AAI to DDD. The cumulative percent ventricular pacing was significantly reduced in the AAISafeR mode compared with the DDD mode (0.9% [0%-3%] versus 51.3% [2%-91%] P = 0.001; 2.94% [0%-18%] versus 41.18% [0%-65%] P = 0.0001). After 3 months in DDD mode, left atrial diameter, left ventricular enddiastolic diameter, and left ventricular end-systolic diameter increased significantly and left ventricular ejection fraction decreased. However, no obvious changes appeared in 3 months of AAISafeR mode. Switches to DDD occurred during follow-up in 21 patients due to different-degree atrial ventricular block. The AAISafeR mode substantially reduces the amount of unnecessary right ventricular pacing in the bradycardia population and effectively prevents the deleterious effects on cardiac performance. An international randomized study will further ascertain the efficacy of this new pacing mode specifically in the prevention of heart failure hospitalization and atrial fibrillation.
Obel, O A; Luddington, L; Maarouf, N; Aytemir, K; Ekwall, C; Malik, M; Camm, A J
2005-01-01
Objective: To prospectively determine whether ventricular rate and regularity are significant determinants of the velocity and magnitude of left atrial appendage (LAA) flow. Design and patients: 12 patients with atrial fibrillation (AF), high degree atrioventricular block, and indwelling permanent pacemakers were studied. Setting: Cardiology department of a tertiary referral centre. Interventions: Pacing was triggered by an external programmable transcutaneous device. Patients were paced at 60, 120, and 150 beats/min in both regular and irregular rhythm. LAA flow velocity and magnitude were assessed with transoesophageal Doppler echocardiography. Main outcome measures: Peak and mean LAA inflow and outflow velocity, and time-velocity interval (TVI) of LAA flow. Results: Increasing ventricular rate was associated with significantly lower peak inflow (p < 0.01), peak outflow (p < 0.05), mean inflow (p < 0.01), and mean outflow (p < 0.05) velocities and with a lower TVI of LAA filling and emptying velocities (p < 0.01). This effect was noted at rates of 60 beats/min compared with both 120 and 150 beats/min. At a pacing rate of 120 beats/min there was a significantly higher total TVI when pacing at a regular than at an irregular rhythm (40.16 (14.6) cm v 30.74 (10.9) cm, p < 0.05). Conclusions: In this study, LAA filling velocities in patients in AF were significantly influenced by paced ventricular rate and to a much lesser extent ventricular rhythm. These results suggest that rapid ventricular rates may predispose to stasis in the LAA in AF. PMID:15894771
Alonso, Alvaro; Jensen, Paul N.; Lopez, Faye L.; Chen, Lin Y.; Psaty, Bruce M.; Folsom, Aaron R.; Heckbert, Susan R.
2014-01-01
Background Sick sinus syndrome (SSS) is a common indication for pacemaker implantation. Limited information exists on the association of sick sinus syndrome (SSS) with mortality and cardiovascular disease (CVD) in the general population. Methods We studied 19,893 men and women age 45 and older in the Atherosclerosis Risk in Communities (ARIC) study and the Cardiovascular Health Study (CHS), two community-based cohorts, who were without a pacemaker or atrial fibrillation (AF) at baseline. Incident SSS cases were validated by review of medical charts. Incident CVD and mortality were ascertained using standardized protocols. Multivariable Cox models were used to estimate the association of incident SSS with selected outcomes. Results During a mean follow-up of 17 years, 213 incident SSS events were identified and validated (incidence, 0.6 events per 1,000 person-years). After adjustment for confounders, SSS incidence was associated with increased mortality (hazard ratio [HR] 1.39, 95% confidence interval [CI] 1.14–1.70), coronary heart disease (HR 1.72, 95%CI 1.11–2.66), heart failure (HR 2.87, 95%CI 2.17–3.80), stroke (HR 1.56, 95%CI 0.99–2.46), AF (HR 5.75, 95%CI 4.43–7.46), and pacemaker implantation (HR 53.7, 95%CI 42.9–67.2). After additional adjustment for other incident CVD during follow-up, SSS was no longer associated with increased mortality, coronary heart disease, or stroke, but remained associated with higher risk of heart failure (HR 2.00, 95%CI 1.51–2.66), AF (HR 4.25, 95%CI 3.28–5.51), and pacemaker implantation (HR 25.2, 95%CI 19.8–32.1). Conclusion Individuals who develop SSS are at increased risk of death and CVD. The mechanisms underlying these associations warrant further investigation. PMID:25285853
Assessing the Risks Associated with MRI in Patients with a Pacemaker or Defibrillator.
Russo, Robert J; Costa, Heather S; Silva, Patricia D; Anderson, Jeffrey L; Arshad, Aysha; Biederman, Robert W W; Boyle, Noel G; Frabizzio, Jennifer V; Birgersdotter-Green, Ulrika; Higgins, Steven L; Lampert, Rachel; Machado, Christian E; Martin, Edward T; Rivard, Andrew L; Rubenstein, Jason C; Schaerf, Raymond H M; Schwartz, Jennifer D; Shah, Dipan J; Tomassoni, Gery F; Tominaga, Gail T; Tonkin, Allison E; Uretsky, Seth; Wolff, Steven D
2017-02-23
The presence of a cardiovascular implantable electronic device has long been a contraindication for the performance of magnetic resonance imaging (MRI). We established a prospective registry to determine the risks associated with MRI at a magnetic field strength of 1.5 tesla for patients who had a pacemaker or implantable cardioverter-defibrillator (ICD) that was "non-MRI-conditional" (i.e., not approved by the Food and Drug Administration for MRI scanning). Patients in the registry were referred for clinically indicated nonthoracic MRI at a field strength of 1.5 tesla. Devices were interrogated before and after MRI with the use of a standardized protocol and were appropriately reprogrammed before the scanning. The primary end points were death, generator or lead failure, induced arrhythmia, loss of capture, or electrical reset during the scanning. The secondary end points were changes in device settings. MRI was performed in 1000 cases in which patients had a pacemaker and in 500 cases in which patients had an ICD. No deaths, lead failures, losses of capture, or ventricular arrhythmias occurred during MRI. One ICD generator could not be interrogated after MRI and required immediate replacement; the device had not been appropriately programmed per protocol before the MRI. We observed six cases of self-terminating atrial fibrillation or flutter and six cases of partial electrical reset. Changes in lead impedance, pacing threshold, battery voltage, and P-wave and R-wave amplitude exceeded prespecified thresholds in a small number of cases. Repeat MRI was not associated with an increase in adverse events. In this study, device or lead failure did not occur in any patient with a non-MRI-conditional pacemaker or ICD who underwent clinically indicated nonthoracic MRI at 1.5 tesla, was appropriately screened, and had the device reprogrammed in accordance with the prespecified protocol. (Funded by St. Jude Medical and others; MagnaSafe ClinicalTrials.gov number, NCT00907361 .).
Simons, G R; Newby, K H; Kearney, M M; Brandon, M J; Natale, A
1998-02-01
The objective of this study was to assess the safety and efficacy of transvenous low energy cardioversion of atrial fibrillation in patients with ventricular tachycardia and atrial fibrillation and to study the mechanisms of proarrhythmia. Previous studies have demonstrated that cardioversion of atrial fibrillation using low energy, R wave synchronized, direct current shocks applied between catheters in the coronary sinus and right atrium is feasible. However, few data are available regarding the risk of ventricular proarrhythmia posed by internal atrial defibrillation shocks among patients with ventricular arrhythmias or structural heart disease. Atrial defibrillation was performed on 32 patients with monomorphic ventricular tachycardia and left ventricular dysfunction. Shocks were administered during atrial fibrillation (baseline shocks), isoproterenol infusion, ventricular pacing, ventricular tachycardia, and atrial pacing. Baseline shocks were also administered to 29 patients with a history of atrial fibrillation but no ventricular arrhythmias. A total of 932 baseline shocks were administered. No ventricular proarrhythmia was observed after well-synchronized baseline shocks, although rare inductions of ventricular fibrillation occurred after inappropriate T wave sensing. Shocks administered during wide-complex rhythms (ventricular pacing or ventricular tachycardia) frequently induced ventricular arrhythmias, but shocks administered during atrial pacing at identical ventricular rates did not cause proarrhythmia. The risk of ventricular proarrhythmia after well-synchronized atrial defibrillation shocks administered during narrow-complex rhythms is low, even in patients with a history of ventricular tachycardia. The mechanism of proarrhythmia during wide-complex rhythms appears not to be related to ventricular rate per se, but rather to the temporal relationship between shock delivery and the repolarization time of the previous QRS complex.
Chen, Yi-Jen; Chen, Yao-Chang; Tai, Ching-Tai; Yeh, Hung-I; Lin, Cheng-I; Chen, Shih-Ann
2006-01-01
Angiotensin II receptor blockers (AIIRBs) have been shown to prevent atrial fibrillation. The pulmonary veins (PVs) are the most important focus for the generation of atrial fibrillation. The aim of this study was to evaluate whether angiotensin II or AIIRB may change the arrhythmogenic activity of the PVs. Conventional microelectrodes and whole-cell patch clamps were used to investigate the action potentials (APs) and ionic currents in isolated rabbit PV tissue and single cardiomyocytes before and after administering angiotensin II or losartan (AIIRB). In the tissue preparations, angiotensin II induced delayed after-depolarizations (1, 10, and 100 nM) and accelerated the automatic rhythm (10 and 100 nM). Angiotensin II (100 nM) prolonged the AP duration and increased the contractile force (10 and 100 nM). Losartan (1 and 10 microM) inhibited the automatic rhythm. Losartan (10 microM) prolonged the AP duration and reduced the contractile force (1 and 10 microM). Angiotensin II reduced the transient outward potassium current (I(to)) but increased the L-type calcium, delayed rectifier potassium (I(K)), transient inward (I(ti)), pacemaker, and Na(+)-Ca(2+) exchanger (NCX) currents in the PV cardiomyocytes. Losartan decreased the I(to), I(K), I(ti), and NCX currents. In conclusion, angiotensin II and AIIRB modulate the PV electrical activity, which may play a role in the pathophysiology of atrial fibrillation.
Diagnostic yield of device interrogation in the evaluation of syncope in an elderly population.
D'Angelo, Robert N; Pickett, Christopher C
2017-06-01
Device interrogation has become a standard part of the syncope evaluation for patients admitted with permanent pacemakers (PPM) or implantable cardiac defibrillators (ICD), although few studies have shown interrogation yields clinically useful data. The purpose of this study is to determine the diagnostic yield of device interrogation as well as other commonly performed tests in the workup of unexplained syncope in patients with previously implanted PPMs or ICDs. We retrospectively reviewed records of 88 patients admitted to our medical center for syncope with previously implanted pacemakers between January 1, 2005 and January 1, 2015 using ICD-9 billing data. Pacemaker interrogation demonstrated an arrhythmia as the cause for syncope in 4 patients (4%) and evidence of device failure secondary to perforation in 1 patient (1%). The cause of syncope was unknown in 34 patients (39%). Orthostatic hypotension was the most commonly identified cause of syncope (26%), followed by vasovagal syncope (13%), autonomic dysfunction (5%), ventricular arrhythmia (3%), atrial arrhythmia (2%), congestive heart failure (2%), stroke (2%), and other less common causes (8%). History was the most important determinant of syncope (36%), followed by orthostatic vital signs (14%), device interrogations (4%), head CT (2%), and transthoracic echocardiogram (1%). Device interrogation is rarely useful for elucidating a cause of syncope without concerning physical exam, telemetry, or EKG findings. Interrogation may occasionally yield paroxysmal arrhythmias responsible for syncopal episode, but these rarely alter clinical outcomes. Interrogation appears to be more useful in patients with syncope after recent device placement. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Götze, S; Butter, C; Fleck, E
2006-01-01
Within the last decade, cardiac resynchronization therapy (CRT) has become an evidence-based cornerstone for a subset of patients with chronic heart failure. For those, who suffer from ischemic or non-ischemic cardiomyopathies at NYHA III or IV, have sinus rhythm, a left bundle branch block and a left ventricular ejection fraction below 35%, CRT has evolved as an important treatment option with promising results. Numerous studies have shown that in these patients pacemaker-mediated correction of intra- and interventicular conduction disturbances can improve not only clinical symptoms, exercise tolerance and the frequency of hospitalizations, but even more important the overall mortality. These clinical results are due to several functional aspects. In the failing heart characteristic intra- and interventricular alterations in electrical conduction result in mechanical asynchrony that leads to an abnormal contraction of the left ventricle with delayed activation of the lateral wall, a paradoxical septal movement, a reduced diastolic filling and a mitral regurgitation due to dyssynchrony of papillary muscle activation. It is conceivable that these functional changes have fatal consequences for the failing heart. AV-optimized left- or biventricular stimulation by modern pacemakers can correct the pathological dyssynchrony, thereby improving cardiac function and clinical outcome in these patients. Although tremendous progress in cardiac resynchronization therapy has been made during the last decade, a couple of questions still need to be resolved. Critical issues are the identification of patients, who will predictably benefit from CRT, the value of CRT-pacemakers versus CRT-ICDs, and the usefullness of CRT in patients with atrial fibrillation.
Manolis, A G; Katsivas, A G; Vassilopoulos, C; Koutsogeorgis, D; Louvros, N E
2002-04-01
Interatrial septum (IAS) pacing seems efficient in synchronizing atrial depolarization in patients (pts) with delayed inter-atrial conduction, but its clinical role in preventing atrial tachyarrhythmias is still debated. This study was conducted in order to evaluate the clinical efficacy of IAS pacing guided by pace mapping of the IAS, as an alternative treatment modality in pts with drug refractory paroxysmal atrial fibrillation (PAF). We evaluated 29 pts (13 male, 16 female, 60 +/- 11 years), with drug refractory PAF, normal sinus node function and prolonged inter-atrial conduction time (P wave 142 +/- 10 ms). Multipolar catheters were inserted and the electrograms from the high right atrium (HRA) and proximal, middle and distal coronary sinus (CS) were recorded. The IAS was paced from multiple sites. The site of IAS where the timing between HRA and distal CS was <20 ms was considered the most suitable for synchronizing the atria. This site was found to be superior to the CS os. near the fossa ovalis in all pts. An active fixation atrial lead was positioned at this site and a standard lead was placed in the right ventricle. During IAS pacing, the P wave duration decreased significantly to 107 +/- 15 ms (P<0.001). At implant, the atrial sensing was 2.3 +/- 0.7 mV, the atrial pacing threshold was 0.95 +/- 0.15 V (0.5 ms) and the impedance was 760 +/- 80 Ohm. We evaluated the pts during four periods of 3 months duration each. The first period (control) was before pacemaker implantation, while the pts were under antiarrhythmic treatment. During the subsequent two periods, we evaluated the clinical efficacy of IAS pacing to prevent PAF recurrences, in AAT (75 bpm) and AAIR (75-140 bpm) mode, with random selection of the order and after discontinuation of antiarrhythmic treatment. During the fourth period, the same AAIR mode was assessed, but antiarrhythmic drugs were also administered. We compared the arrhythmia free interval among the four periods. The proportion of atrial paced beats in AAIR pacing mode plus antiarrhythmics was significantly higher compared with the drug-free period in AAIR mode (57 +/- 9% and 49 +/- 9% respectively, P=0017) and with AAT pacing mode (44 +/- 10%,(, P<0.001). In AAT mode, the arrhythmia free interval was 24.2 +/- 5.1 days, while it was 26.2 +/- 5.7 days in AAIR mode. These intervals did not differ significantly from the pre-implantation period (24.1 +/- 6.3 days). The arrhythmia free interval in AAIR pacing in combination with antiarrhythmic drug therapy was 38.7 +/- 8.1 days and this was significantly longer than the previous periods (P<0.05). Atrial septal pacing in combination with antiarrhythmic drug therapy reduced the incidence of PAF in pts with prolonged inter-atrial conduction times. Pace mapping of the IAS is an attractive technique to assess the shortest atrial activation time between HRA and distal CS. Whether placement of the atrial lead based on the shortest HRA--distal CS time is the best place in the IAS to prevent PAF still remains to be proven.
A KCNQ1 mutation causes age-dependant bradycardia and persistent atrial fibrillation.
Ki, Chang-Seok; Jung, Chae Lim; Kim, Hyun-ji; Baek, Kwan-Hyuck; Park, Seung Jung; On, Young Keun; Kim, Ki-Suk; Noh, Su Jin; Youm, Jae Boum; Kim, June Soo; Cho, Hana
2014-03-01
Atrial fibrillation (AF) is the most common arrhythmia. Gain-of-function mutations in KCNQ1, the pore-forming α-subunit of the slow delayed rectifier K current (IKs) channel, have been associated with AF. The purpose of this study was functional assessment of a mutation in KCNQ1 identified in a family with persistent AF and sinus bradycardia. We investigated whether this KCNQ1 missense mutation could form the genetic basis for AF and bradycardia simultaneously in this family. Sanger sequencing in a family with hereditary persistent AF identified a novel KCNQ1 variant (V241F) in a highly conserved region of S4 domain. The proband and her son developed bradycardia and persistent AF in an age-dependent fashion. The other son was a mutation carrier but he showed sinus bradycardia and not AF. Whole-cell patch clamp electrophysiology showed that V241F mutation in KCNQ1 shifted the activation curve to the left and dramatically slowed deactivation, leading to a constitutively open-like phenotype. Computer modeling showed that V241F would slow pacemaker activity. Also, simulations of atrial excitation predicted that V241F results in extreme shortening of action potential duration, possibly resulting in AF. Our study indicates that V241F might cause sinus bradycardia by increasing IKs. Additionally, V241F likely shortens atrial refractoriness to promote a substrate for reentry. KCNQ1 mutations have previously been described in AF, yet this is the first time a mutation in KCNQ1 is associated with age-dependent bradycardia and persistent AF. This finding further supports the hypothesis that sinus node dysfunction contributes to the development of AF.
Wang, Xiaozhan; Zhao, Qingyan; Deng, Hongping; Wang, Xule; Guo, Zongwen; Dai, Zixuan; Xiao, Jinping; Wan, Peixing; Huang, Congxin
2014-10-01
Heart failure (HF) and atrial fibrillation (AF) are associated with sympathetic activation. Renal sympathetic denervation (RSD) can suppress AF vulnerability. The impact of RSD on atrial electrophysiology in experimental HF is unclear. Twenty-two beagles were randomized into control, HF, and HF + RSD groups. Control dogs were implanted cardiac pacemakers without pacing. Dogs in the HF group underwent right ventricular pacing for 3 weeks at 240 beats/min to induce HF. The dogs in the HF + RSD group received RSD and underwent the same HF-inducing procedure. The P-wave dispersion was higher in HF dogs than in the control and HF + RSD dogs (19 ± 3.1 ms vs 13 ± 2.3 ms, 15 ± 2.9 ms, P = 0.04). Conduction time within the interatrium was significantly longer in the HF dogs than that in the control and HF + RSD dogs (39 ± 4 ms vs 31 ± 3 ms, 33 ± 4 ms; P = 0.03). Window of vulnerability (WOV) of AF was widened in the HF dogs than in the HF + RSD dogs (37 ± 5 ms vs 14 ± 3 ms; P < 0.01), while AF could not be induced (WOV = 0) in the control dogs during S1 S2 stimulation. The voltage in the threshold for AF inducibility was lower during ganglionated plexi stimulation in the HF dogs than in the control and HF + RSD dogs (1.8 ± 0.6 V vs 2.5 ± 0.6 V, 2.4 ± 0.4 V; P = 0.04). RSD could reverse the atrial electrical remodeling and decrease AF inducibility in dogs with pacing-induced HF. ©2014 Wiley Periodicals, Inc.
Influence of verapamil on tachycardia-induced alterations of PP1 and PP2A in rabbit atrium
Laszlo, Roman; Winkler, Christoph; Wöhrl, Stefan; Laszlo, Sara; Eick, Christian; Schreieck, Jürgen; Bosch, Ralph F
2007-01-01
BACKGROUND Long-term atrial fibrillation changes in many regulatory and structural processes may result in stabilization of the arrhythmia. There is evidence that decreased amplitude of L-type Ca2+ current – probably a key mechanism of atrial remodelling –resulting from changes in expression of regulatory proteins is at least jointly responsible. OBJECTIVES To assess the expressions of protein phosphatases PP1 and PP2A, as well as the effect of verapamil pretreatment (VPT), in the early phases of atrial fibrillation in a rabbit model. METHODS Four groups, each consisting of six animals, were studied: ‘not paced, no drug’ group; ‘paced, no drug’ group (rapid atrial pacing [RAP] 600 beats/min for 24 h); ‘not paced, verapamil’ (NPV) group (duration of VPT was seven days, verapamil 7.5 mg/kg was administered every 12 h); and ‘paced, verapamil’ (PV) group (pacemaker stimulation after VPT). Protein expression was evaluated by Western blot analysis. RESULTS RAP resulted in an augmented (32%) PP1 expression (not paced, no drug group versus paced, no drug group). The increase in PP1 expression was prevented with VPT (NPV group versus PV group). Expression of PP2A was not influenced by RAP. However, VPT led to an increase of PP2A expression (16%) after RAP (NPV group versus PV group). CONCLUSIONS Fortified expression of protein phosphatases might be – besides transcriptional downregulation of channel subunits – another important cause of reduced L-type Ca2+ current after RAP. Blocking L-type Ca2+ channels with verapamil to prevent tachycardia-induced changes of PP1 expression might be expedient. PMID:18651001
Approaches to catheter ablation for persistent atrial fibrillation.
Verma, Atul; Jiang, Chen-yang; Betts, Timothy R; Chen, Jian; Deisenhofer, Isabel; Mantovan, Roberto; Macle, Laurent; Morillo, Carlos A; Haverkamp, Wilhelm; Weerasooriya, Rukshen; Albenque, Jean-Paul; Nardi, Stefano; Menardi, Endrj; Novak, Paul; Sanders, Prashanthan
2015-05-07
Catheter ablation is less successful for persistent atrial fibrillation than for paroxysmal atrial fibrillation. Guidelines suggest that adjuvant substrate modification in addition to pulmonary-vein isolation is required in persistent atrial fibrillation. We randomly assigned 589 patients with persistent atrial fibrillation in a 1:4:4 ratio to ablation with pulmonary-vein isolation alone (67 patients), pulmonary-vein isolation plus ablation of electrograms showing complex fractionated activity (263 patients), or pulmonary-vein isolation plus additional linear ablation across the left atrial roof and mitral valve isthmus (259 patients). The duration of follow-up was 18 months. The primary end point was freedom from any documented recurrence of atrial fibrillation lasting longer than 30 seconds after a single ablation procedure. Procedure time was significantly shorter for pulmonary-vein isolation alone than for the other two procedures (P<0.001). After 18 months, 59% of patients assigned to pulmonary-vein isolation alone were free from recurrent atrial fibrillation, as compared with 49% of patients assigned to pulmonary-vein isolation plus complex electrogram ablation and 46% of patients assigned to pulmonary-vein isolation plus linear ablation (P=0.15). There were also no significant differences among the three groups for the secondary end points, including freedom from atrial fibrillation after two ablation procedures and freedom from any atrial arrhythmia. Complications included tamponade (three patients), stroke or transient ischemic attack (three patients), and atrioesophageal fistula (one patient). Among patients with persistent atrial fibrillation, we found no reduction in the rate of recurrent atrial fibrillation when either linear ablation or ablation of complex fractionated electrograms was performed in addition to pulmonary-vein isolation. (Funded by St. Jude Medical; ClinicalTrials.gov number, NCT01203748.).
Concomitant atrial fibrillation surgery for people undergoing cardiac surgery
Huffman, Mark D; Karmali, Kunal N; Berendsen, Mark A; Andrei, Adin-Cristian; Kruse, Jane; McCarthy, Patrick M; Malaisrie, S C
2016-01-01
Background People with atrial fibrillation (AF) often undergo cardiac surgery for other underlying reasons and are frequently offered concomitant AF surgery to reduce the frequency of short- and long-term AF and improve short- and long-term outcomes. Objectives To assess the effects of concomitant AF surgery among people with AF who are undergoing cardiac surgery on short-term and long-term (12 months or greater) health-related outcomes, health-related quality of life, and costs. Search methods Starting from the year when the first “maze” AF surgery was reported (1987), we searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library (March 2016), MEDLINE Ovid (March 2016), Embase Ovid (March 2016), Web of Science (March 2016), the Database of Abstracts of Reviews of Effects (DARE, April 2015), and Health Technology Assessment Database (HTA, March 2016). We searched trial registers in April 2016. We used no language restrictions. Selection criteria We included randomised controlled trials evaluating the effect of any concomitant AF surgery compared with no AF surgery among adults with preoperative AF, regardless of symptoms, who were undergoing cardiac surgery for another indication. Data collection and analysis Two review authors independently selected studies and extracted data. We evaluated the risk of bias using the Cochrane ‘Risk of bias’ tool. We included outcome data on all-cause and cardiovascular-specific mortality, freedom from atrial fibrillation, flutter, or tachycardia off antiarrhythmic medications, as measured by patient electrocardiographic monitoring greater than three months after the procedure, procedural safety, 30-day rehospitalisation, need for post-discharge direct current cardioversion, health-related quality of life, and direct costs. We calculated risk ratios (RR) for dichotomous data with 95% confidence intervals (CI) using a fixed-effect model when heterogeneity was low (I2 ≤ 50%) and random-effects model when heterogeneity was high (I2 > 50%). We evaluated the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework to create a ‘Summary of findings’ table. Main results We found 34 reports of 22 trials (1899 participants) with five additional ongoing studies and three studies awaiting classification. All included studies were assessed as having high risk of bias across at least one domain. The effect of concomitant AF surgery on all-cause mortality was uncertain when compared with no concomitant AF surgery (7.0% versus 6.6%, RR 1.14, 95% CI 0.81 to 1.59, I2 = 0%, 20 trials, 1829 participants, low-quality evidence), but the intervention increased freedom from atrial fibrillation, atrial flutter, or atrial tachycardia off antiarrhythmic medications > three months (51.0% versus 24.1%, RR 2.04, 95% CI 1.63 to 2.55, I2 = 0%, eight trials, 649 participants, moderate-quality evidence). The effect of concomitant AF surgery on 30-day mortality was uncertain (2.3% versus 3.1%, RR 1.25 95% CI 0.71 to 2.20, I2 = 0%, 18 trials, 1566 participants, low-quality evidence), but the intervention increased the risk of permanent pacemaker implantation (6.0% versus 4.1%, RR 1.69, 95% CI 1.12 to 2.54, I2 = 0%, 18 trials, 1726 participants, moderate-quality evidence). Investigator-defined adverse events, including but limited to, need for surgical re-exploration or mediastinitis, were not routinely reported but were not different between the two groups (other adverse events: 24.8% versus 23.6%, RR 1.07, 95% CI 0.85 to 1.34, I2 = 45%, nine trials, 858 participants), but the quality of this evidence was very low. Authors’ conclusions For patients with AF undergoing cardiac surgery, there is moderate-quality evidence that concomitant AF surgery approximately doubles the risk of freedom from atrial fibrillation, atrial flutter, or atrial tachycardia off anti-arrhythmic drugs while increasing the risk of permanent pacemaker implantation. The effects on mortality are uncertain. Future, high-quality and adequately powered trials will likely affect the confidence on the effect estimates of AF surgery on clinical outcomes. PMID:27551927
Bachmann bundle pacing reduces atrial electromechanical delay in type 1 myotonic dystrophy patients.
Russo, Vincenzo; Rago, Anna; Papa, Andrea Antonio; Arena, Giulia; Politano, Luisa; Nigro, Gerardo
2018-04-01
Atrial electromechanical delay (AEMD) is an echocardiographic parameter correlated with the onset of supraventricular arrhythmias in several clinical conditions. Inter-atrial septal pacing in the region of Bachmann's bundle (BB) has been shown to be safe and feasible in myotonic dystrophy type 1 (DM1) patients, with a low rate of sensing and pacing defects. The aim of this study was to assess the impact of temporary BB pacing compared with right atrial appendage (RAA) pacing on AEMD in DM1 patients undergoing pacemaker (PM) implantation for cardiac rhythm abnormalities. The study enrolled 70 consecutive DM1 patients undergoing PM implantation for cardiac rhythm abnormalities in accordance with the current guidelines. Seventy age- and sex-matched non-DM1 patients undergoing dual-chamber PM implantation for cardiac rhythm abnormalities were used as controls. The atrial pacing lead was temporarily positioned in the RAA and on the right side of the inter-atrial septum in the region of Bachmann's bundle. For each site (BB and RAA), temporary atrial pacing in the AAI mode was established at 10 beats per minute above the sinus rate and a detailed trans-thoracic echocardiogram with tissue Doppler (TDI) analysis was recorded after at least 10 min of atrial pacing to evaluate AEMD. Temporary RAA pacing did not show statistically significant differences in inter-AEMD (48.2 ± 17.8 vs 50.5 ± 16.5 ms; P = 0.8), intra-left AEMD (43.3 ± 15.5 vs 44.6 ± 15.8 ms; P = 0.1), or intra-right-AEMD (14.1 ± 4.2 vs 15.4 ± 5.8 ms; P = 0.9), in comparison with sinus rhythm. Temporary BB pacing determined a significantly lower inter-AEMD (36.1 ± 17.1 vs 50.5 ± 16.5 ms; P = 0.001) and intra-left AEMD (32.5 ± 15.2 vs 44.6 ± 15.8 ms; P = 0.001) values in comparison with temporary RAA pacing. No statistically significant difference was found in intra-right AEMD (12.2 ± 4.6 vs 15.4 ± 5.8 ms; P = 0.2). In the control group, neither temporary RAA pacing nor temporary BB pacing showed statistically significant differences in inter-AEMD, intra-left AEMD, or intra-right AEMD values in comparison with sinus rhythm. In DM1 patients undergoing dual-chamber PM implantation, atrial pacing in the Bachmann bundle region is associated with significantly lower echocardiographic indices of atrial electromechanical delay (inter-AEMD and intra-left AEMD) in comparison with RAA pacing.
Ishikawa, Taisuke; Ohno, Seiko; Murakami, Takashi; Yoshida, Kentaro; Mishima, Hiroyuki; Fukuoka, Tetsuya; Kimoto, Hiroki; Sakamoto, Risa; Ohkusa, Takafumi; Aiba, Takeshi; Nogami, Akihiko; Sumitomo, Naokata; Shimizu, Wataru; Yoshiura, Koh-Ichiro; Horigome, Hitoshi; Horie, Minoru; Makita, Naomasa
2017-05-01
Familial sick sinus syndrome (SSS) is often attributable to mutations in genes encoding the cardiac Na channel SCN5A and pacemaker channel HCN4. We previously found that SSS with SCN5A mutations shows early onset of manifestations and male predominance. Despite recent reports on the complications of atrial fibrillation (AF) and left ventricular noncompaction (LVNC) in patients with SSS caused by HCN4 mutations, their overall clinical spectrum remains unknown. The purpose of this study was to investigate the clinical and demographic features of SSS patients carrying HCN4 mutations. We genetically screened 38 unrelated SSS families and functionally analyzed the mutant SCN5A and HCN4 channels by patch clamping. We also evaluated the clinical features of familial SSS by a meta-analysis of 48 SSS probands with mutations in HCN4 (n = 16) and SCN5A (n = 32), including previously reported cases, and 538 sporadic SSS cases. We identified two HCN4 and three SCN5A loss-of-function mutations in our familial SSS cohort. Meta-analysis of HCN4 mutation carriers showed a significantly younger age at diagnosis (39.1 ± 21.7 years) than in sporadic SSS (74.3 ± 0.4 years; P <.001), but a significantly older age than in SCN5A mutation carriers (20.0 ± 17.6 years; P = .003). Moreover, HCN4 mutation carriers were more frequently associated with AF (43.8%) and LVNC (50%) and with older age at pacemaker implantation (43.5 ± 22.1 years) than were SCN5A mutation carriers (17.8 ± 16.5 years; P <.001). SSS with HCN4 mutations may form a distinct SSS subgroup characterized by early clinical manifestation after adolescence and frequent association with AF and LVNC. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Hyperthyroidism and atrial myxoma--an intriguing cardio-endocrine association.
Kumar, Gautam; Chow, John T; Klarich, Kyle W; Dean, Diana S
2007-12-01
A 65-year-old woman presented with dyspnea and bilateral leg edema for 1 week, worsening fatigue for 1 month, and a 7-lb weight loss over the last summer. She was clinically and biochemically hyperthyroid. Echocardiography revealed a left atrial myxoma measuring 6.2 x 3.3 cm protruding into the mitral orifice and left ventricle during diastole. She was treated for Graves' disease with Iodine-131. Six weeks later, her left atrial myxoma measuring 10.1 x 6.2 x 2.4 cm was resected. She became euthyroid before surgery and then biochemically hypothyroid 6 weeks after radioiodine treatment, for which she subsequently required thyroxine replacement. Atrial myxomas are the most common primary cardiac neoplasms. At least 5% to 10% can be attributed to Carney's complex. More than two-thirds of patients with Carney's complex develop one or more cardiac myxomas. Although atrial myxomas in Carney's complex are histologically indistinguishable from the sporadic form, their clinical presentation and course is distinct. This is the first case of newly diagnosed Graves' disease that has been reported in association with an atrial myxoma. The features discussed in this article help differentiate between syndromic and sporadic atrial myxomas.
Albers, H. Elliott; Walton, James C.; Gamble, Karen L.; McNeill, John K.; Hummer, Daniel L.
2016-01-01
Virtually every neuron within the suprachiasmatic nucleus (SCN) communicates via GABAergic signaling. The extracellular levels of GABA within the SCN are determined by a complex interaction of synthesis and transport, as well as synaptic and non-synaptic release. The response to GABA is mediated by GABAA receptors that respond to both phasic and tonic GABA release and that can produce excitatory as well as inhibitory cellular responses. GABA also influences circadian control through the exclusively inhibitory effects of GABAB receptors. Both GABA and neuropeptide signaling occur within the SCN, although the functional consequences of the interactions of these signals are not well understood. This review considers the role of GABA in the circadian pacemaker, in the mechanisms responsible for the generation of circadian rhythms, in the ability of non-photic stimuli to reset the phase of the pacemaker, and in the ability of the day-night cycle to entrain the pacemaker. PMID:27894927
[Fetal bradycardia: a retrospective study in 9 Spanish centers].
Perin, F; Rodríguez Vázquez del Rey, M M; Deiros Bronte, L; Ferrer Menduiña, Q; Rueda Nuñez, F; Zabala Arguelles, J I; García de la Calzada, D; Teodoro Marin, S; Centeno Malfaz, F; Galindo Izquierdo, A
2014-11-01
The aim of this study is to review the current management and outcomes of fetal bradycardia in 9 Spanish centers. Retrospective multicenter study: analysis of all fetuses with bradycardia diagnosed between January 2008 and September 2010. Underlying mechanisms of fetal bradyarrhythmias were studied with echocardiography. A total of 37 cases were registered: 3 sinus bradycardia, 15 blocked atrial bigeminy, and 19 high grade atrioventricular blocks. Sinus bradycardia: 3 cases (100%) were associated with serious diseases. Blocked atrial bigeminy had an excellent outcome, except for one case with post-natal tachyarrhythmia. Of the atrioventricular blocks, 16% were related to congenital heart defects with isomerism, 63% related to the presence of maternal SSA/Ro antibodies, and 21% had unclear etiology. Overall mortality was 20% (37%, if terminations of pregnancy are taken into account). Risk factors for mortality were congenital heart disease, hydrops and/or ventricular dysfunction. Management strategies differed among centers. Steroids were administrated in 73% of immune-mediated atrioventricular blocks, including the only immune-mediated IInd grade block. More than half (58%) of atrioventricular blocks had a pacemaker implanted in a follow-up of 18 months. Sustained fetal bradycardia requires a comprehensive study in all cases, including those with sinus bradycardia. Blocked atrial bigeminy has a good prognosis, but tachyarrhythmias may develop. Heart block has significant mortality and morbidity rates, and its management is still highly controversial. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Disease management: atrial fibrillation and home monitoring.
Ricci, Renato Pietro
2013-06-01
Device-detected atrial fibrillation (AF) episodes predict poor clinical outcome regardless of symptoms. Potential benefits of remote monitoring are early arrhythmia detection and patient continuous monitoring. Several studies of device remote monitoring consistently demonstrated that AF represents the most common clinical alert and that detailed information on arrhythmia onset, duration, and burden as well as on the ventricular rate may be early available for clinical evaluation. Reaction time to AF alerts was very short in all series involving either pacemakers or defibrillators and action ability of AF alerts was very high. In the Home Guide Registry, in which 1650 patients were enrolled, AF was detected in 16.3% of patients and represented 36% of all cardiovascular events during the follow-up. Timely anticoagulation introduction in asymptomatic patients may impact on the stroke rate. According to the results of repeated Monte Carlo simulations based on a real population of 166 patients, daily monitoring may reduce the 2-year stroke risk by 9-18% with an absolute reduction of 0.2-0.6%, compared with conventional inter-visit intervals of 6-12 months. In the COMPAS trial, the incidence of hospitalizations for atrial arrhythmias and related stroke was significantly higher in the control group than in the remote monitoring group. Major questions will be addressed by the ongoing IMPACT trial in which a remote monitoring guided anticoagulation strategy based on AF detection will be compared with a physician-directed standard strategy. In patients with heart failure, AF early detection combined with other indexes may help prevent hospitalizations.
van der Boon, Robert M A; Van Mieghem, Nicolas M; Theuns, Dominic A; Nuis, Rutger-Jan; Nauta, Sjoerd T; Serruys, Patrick W; Jordaens, Luc; van Domburg, Ron T; de Jaegere, Peter P T
2013-09-30
To determine pacemaker (PM) dependency at follow-up visit in patients who underwent new permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI). Single center prospective observational study including 167 patients without previous PM implantation who underwent TAVI with the self-expanding Medtronic CoreValve System (MCS) between November 2005 and February 2011. PM dependency was defined by the presence of a high degree atrioventricular block (HDAVB; second [AV2] and third degree [AV3B]), or a slow (<30 bpm) or absent ventricular escape rhythm during follow-up PM interrogation. A total of 36 patients (21.6%) received a new PM following TAVI. The indication for PM was AV2B (n=2, 5.6%), AV3B (n=28, 77.8%), postoperative symptomatic bradycardia (n=3, 8.3%), brady-tachy syndrome (n=1, 2.8%), atrial fibrilation with slow response (n=1, 2.8%) and left bundle branch block (n=1, 2.8%). Long term follow-up was complete for all patients and ranged from 1 to 40 months (median (IQR): 11.5 (5.0-18.0 months). Of those patients with a HDAVB, 16 out of the 30 patients (53.3%) were PM independent at follow-up visit (complete or partial resolution of the AV conduction abnormality). Overall, 20 out of the 36 patients (55.6%) who received a new PM following TAVI were PM independent at follow-up. Partial and even complete resolution of peri-operative AV conduction abnormalities after MCS valve implantation occurred in more than half of the patients. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Transcatheter leadless cardiac pacing: The new alternative solution.
Da Costa, Antoine; Axiotis, Amandine; Romeyer-Bouchard, Cécile; Abdellaoui, Loucif; Afif, Zahi; Guichard, Jean Baptiste; Gerbay, Antoine; Isaaz, Karl
2017-01-15
A lack of information about the feasibility and safety of leadless pacemaker (LPMs) exists in a fragile population of patients with limited venous anatomy access or conventional pacemaker (PM) contraindication. Accordingly, the goal of this prospective observational study was to report our experience with this new leadless technology in a subset of patients with contraindication or limited venous access. Between May 2015 and July 2016, 14 patients were consecutively included. The indications for initial PM implantation were atrioventricular (AV) block in 10/14 patients (71%), bradyarrhythmia in one (7%), and uncontrolled atrial fibrillation (AFib) requiring AV-node ablation in three (21.5%). AFib was observed in 9 of the 14 patients (64.3%) and 3 were completely dependent with no escape rhythm (21.5%). Normal access pathways via the right or left subclavian veins were occluded due to previous PM implantations and revisions in 4 patients (28.6%) and total vena cava occlusion in 3 (21.4%). End-stage renal disease with hemodialysis was present in 8 (57%) with either local-device infections or presence of long-term implanted dialysis catheters. Evidence of previous bilaterally-infected pectoral tissue was present in 3 patients (21.5%). All procedures were successful (100%) and electrical parameters remained stable over time. No direct pacemaker-related adverse events were reported, including mechanical complications, except for one ventricular fibrillation one day post-implantation under very specific conditions. This series demonstrated very stable performance and reassuring safety results during mid-term follow-up in a very fragile population requiring a PM. The Micra LPM constitutes an excellent alternative to the epicardial surgical approach in this very fragile population. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Dijkman, B; Wellens, H J
2001-09-01
Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.
Stein, D G; Laks, H; Drinkwater, D C; Permut, L C; Louie, H W; Pearl, J M; George, B L; Williams, R G
1991-08-01
Total cavopulmonary connection was proposed as a modification of the Fontan procedure that might have greater benefits than previous methods. To assess this procedure we reviewed case histories of 38 patients (aged 17 months to 30 years) who underwent Fontan procedures with cavopulmonary anastomoses between January 1987 and December 1989. The group included 32 patients with univentricular heart, 2 with pulmonary atresia and intact ventricular septum, 3 with tricuspid atresia, and 1 with hypoplastic left heart syndrome. One or more previous palliative procedures were performed in 34 patients, including 19 systemic-pulmonary shunts, 16 pulmonary artery bandings, 7 atrial septectomies/septostomies, 7 Glenn shunts, and 1 patent ductus arteriosus ligation. Preoperative hemodynamics showed a pulmonary artery pressure of 12 mm Hg (range 6 to 22 mm Hg), pulmonary-systemic flow ratio of 1.6 (range 0.37 to 3.0), left ventricular end-diastolic pressure 9 mm Hg (range 3 to 15 mm Hg), and systemic arterial oxygen saturation of 82% (range 67% to 94%). Concomitant with cavopulmonary connection, 13 patients underwent additional procedures, including 9 atrioventricular valve annuloplasties, 4 Damus-Stansel-Kaye procedures, and 2 resections of subaortic membranes. Modifying the Fontan procedure in this fashion was particularly useful in the management of 2 patients with pulmonary atresia and intact ventricular septum who had right ventricular-dependent coronary blood flow. Cavopulmonary anastomosis and atrial septectomy were performed in both patients, with resultant inflow of oxygenated blood to the right ventricle and coronary arteries. Excellent postoperative results were noted in each. Postextubation hemodynamics for the entire group included a mean right atrial pressure of 13 mm Hg (range 11 to 17 mm Hg), a mean left atrial pressure of 6 mm Hg (range 3 to 12 mm Hg), and a room air oxygen saturation of 96% (range 92% to 98%). Seven patients had pleural effusions, 3 required postoperative pacemaker placement, and 2 required reoperation for tamponade. A venous assist device was required in one patient on the second postoperative day, but the patient was weaned successfully within 24 hours. One early death (2.6%) occurred in a patient who had intractable ventricular fibrillation 2 days after operation. There was one late cardiac death (2.7%) caused by ventricular failure and one late noncardiac death. These results demonstrate that total cavopulmonary connection provides excellent early definitive treatment, with low morbidity and mortality, for a variety of complex congenital heart lesions.
Abramochkin, Denis V; Karimova, Viktoria M; Filatova, Tatiana S; Kamkin, Andre
2017-07-01
Diadenosine pentaphosphate (Ap5A) belongs to the family of diadenosine polyphosphates, endogenously produced compounds that affect vascular tone and cardiac performance when released from platelets. The previous findings indicate that Ap5A shortens action potentials (APs) in rat myocardium via activation of purine P2 receptors. The present study demonstrates alternative mechanism of Ap5A electrophysiological effects found in guinea pig myocardium. Ap5A (10 -4 M) shortens APs in guinea pig working atrial myocardium and slows down pacemaker activity in the sinoatrial node. P1 receptors antagonist DPCPX (10 -7 M) or selective GIRK channels blocker tertiapin (10 -6 M) completely abolished all Ap5A effects, while P2 blocker PPADS (10 -4 M) was ineffective. Patch-clamp experiments revealed potassium inward rectifier current activated by Ap5A in guinea pig atrial myocytes. The current was abolished by DPCPX or tertiapin and therefore was considered as potassium acetylcholine-dependent inward rectifier (I KACh ). Thus, unlike rat, in guinea pig atrium Ap5A produces activation of P1 receptors and subsequent opening of KACh channels leading to negative effects on cardiac electrical activity.
Essential Role of the m2R-RGS6-IKACh Pathway in Controlling Intrinsic Heart Rate Variability
Posokhova, Ekaterina; Ng, David; Opel, Aaisha; Masuho, Ikuo; Tinker, Andrew; Biesecker, Leslie G.; Wickman, Kevin; Martemyanov, Kirill A.
2013-01-01
Normal heart function requires generation of a regular rhythm by sinoatrial pacemaker cells and the alteration of this spontaneous heart rate by the autonomic input to match physiological demand. However, the molecular mechanisms that ensure consistent periodicity of cardiac contractions and fine tuning of this process by autonomic system are not completely understood. Here we examined the contribution of the m2R-IKACh intracellular signaling pathway, which mediates the negative chronotropic effect of parasympathetic stimulation, to the regulation of the cardiac pacemaking rhythm. Using isolated heart preparations and single-cell recordings we show that the m2R-IKACh signaling pathway controls the excitability and firing pattern of the sinoatrial cardiomyocytes and determines variability of cardiac rhythm in a manner independent from the autonomic input. Ablation of the major regulator of this pathway, Rgs6, in mice results in irregular cardiac rhythmicity and increases susceptibility to atrial fibrillation. We further identify several human subjects with variants in the RGS6 gene and show that the loss of function in RGS6 correlates with increased heart rate variability. These findings identify the essential role of the m2R-IKACh signaling pathway in the regulation of cardiac sinus rhythm and implicate RGS6 in arrhythmia pathogenesis. PMID:24204714
Palmisano, Pietro; Ziacchi, Matteo; Biffi, Mauro; Ricci, Renato P; Landolina, Maurizio; Zoni-Berisso, Massimo; Occhetta, Eraldo; Maglia, Giampiero; Botto, Gianluca; Padeletti, Luigi; Boriani, Giuseppe
2018-04-01
: The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients' clinical features. In part 2, criteria for pacemaker choice and programming in atrioventricular blocks and neurally mediate syncope are proposed. The atrioventricular blocks can be paroxysmal or persistent, isolated or associated with sinus node disease. Neurally mediated syncope can be related to carotid sinus syndrome or cardioinhibitory vasovagal syncope. In sinus rhythm, with persistent atrioventricular block, we considered appropriate the activation of mode-switch algorithms, and algorithms for auto-adaptive management of the ventricular pacing output. If the atrioventricular block is paroxysmal, in addition to algorithms mentioned above, algorithms to maximize intrinsic atrioventricular conduction should be activated. When sinus node disease is associated with atrioventricular block, the activation of rate-responsive function in patients with chronotropic incompetence is appropriate. In permanent atrial fibrillation with atrioventricular block, algorithms for auto-adaptive management of the ventricular pacing output should be activated. If the atrioventricular block is persistent, the activation of rate-responsive function is appropriate. In carotid sinus syndrome, adequate rate hysteresis should be programmed. In vasovagal syncope, specialized sensing and pacing algorithms designed for reflex syncope prevention should be activated.
Electrogram fractionation in murine HL-1 atrial monolayer model.
Umapathy, Karthikeyan; Masse, Stephane; Kolodziejska, Karolina; Veenhuyzen, George D; Chauhan, Vijay S; Husain, Mansoor; Farid, Talha; Downar, Eugene; Sevaptsidis, Elias; Nanthakumar, Kumaraswamy
2008-07-01
Complex fractionated atrial electrograms have been suggested as important targets for catheter ablation of atrial fibrillation. The etiology and the mechanism of these signals have not been completely elucidated because of limitations of interpretation of these signals in relation to simultaneously acquired signals in the neighboring atrial tissue. This study sought to study the origin of electrogram fractionation under the conditions of rotor formation and wave fragmentation, using atrial monolayer preparations. We performed optical mapping of 45 atrial monolayer preparations using a complementary metal oxide semiconductor (CMOS) Brainvision Ultima camera system (SciMedia-Brainvision, Tokyo, Japan). We observed stable rotors in 32 of the 45 recordings. The derived bipolar electrograms did not show complex fractionation at the core of the rotor in any of the 32 recordings. We were also able to show that 2 bipolar electrodes placed adjacent to the core of a stable rotor in a zone where there is no wave break will record electrical activity for the majority of the rotor's cycle length. In 13 of the 45 recordings, wave break or wave collision events were present. Of these, 8 of 13 recordings showed complex fractionation. In 19 of the 27, simulation of meandering rotors also showed complex fractionation. Complex fractionated electrograms can be recorded at sites of migrating rotors and wave break. No fractionation occurs at the core of a stable rotor. Electrograms that span the rotor cycle length and alternate between 2 bipoles that straddle the core can identify site of a stable rotor.
Golshmid, M V; Gilyarevskiy, S R; Kuzmina, I M; Sinitsina, I I
The article discusses the issue of searching for optimum oral anticoagulants to prevent thrombosis and embolism induced by heart disease both in patients with atrial fibrillation and sinus rhythm. A complex bidirectional relationship between atrial fibrillation and coronary atherosclerosis is considered along with possible mechanisms for development of myocardial infarction in patients with atrial fibrillation. The authors provided evidence-based data which can be used in selecting an anticoagulant for prevention of heart disease induced thrombosis and embolism taking into account both the efficacy and safety established in randomized clinical studies.
Ben-Mabrouk, Faiza; Tryba, Andrew Kieran
2011-01-01
Neuromodulators, such as Substance P (SubP) play an important role in modulating many rhythmic activities driven by central pattern generators (e.g., locomotion, respiration). However, the mechanism by which SubP enhances breathing regularity has not been determined. Here, we used mouse brainstem slices containing the pre-Bötzinger Complex (Pre-BötC) to demonstrate, for the first time, that SubP activates transient receptor protein canonical (TRPC) channels to enhance respiratory rhythm regularity. Moreover, SubP enhancement of network regularity is accomplished via selective enhancement of ICAN-dependent intrinsic bursting properties. In contrast to INaP-dependant pacemakers, ICAN-dependant pacemaker bursting activity is TRPC dependent. Western Blots reveal TRPC3 and TRPC7 channels are expressed in rhythmically active ventral respiratory group (VRG) island preparations. Taken together, these data suggest that SubP-mediated activation of TRPC3/7 channels underlies rhythmic ICAN-dependent pacemaker activity and enhances the regularity of respiratory rhythm activity. PMID:20345918
Ben-Mabrouk, Faiza; Tryba, Andrew K
2010-04-01
Neuromodulators, such as substance P (SubP), play an important role in modulating many rhythmic activities driven by central pattern generators (e.g. locomotion, respiration). However, the mechanism by which SubP enhances breathing regularity has not been determined. Here, we used mouse brainstem slices containing the pre-Bötzinger complex to demonstrate, for the first time, that SubP activates transient receptor protein canonical (TRPC) channels to enhance respiratory rhythm regularity. Moreover, SubP enhancement of network regularity is accomplished via selective enhancement of ICAN (inward non-specific cation current)-dependent intrinsic bursting properties. In contrast to INaP (persistent sodium current)-dependent pacemakers, ICAN-dependent pacemaker bursting activity is TRPC-dependent. Western Blots reveal TRPC3 and TRPC7 channels are expressed in rhythmically active ventral respiratory group island preparations. Taken together, these data suggest that SubP-mediated activation of TRPC3/7 channels underlies rhythmic ICAN-dependent pacemaker activity and enhances the regularity of respiratory rhythm activity.
Computer Three-Dimensional Reconstruction of the Atrioventricular Node
Li, Jue; Greener, Ian D.; Inada, Shin; Nikolski, Vladimir P.; Yamamoto, Mitsuru; Hancox, Jules C.; Zhang, Henggui; Billeter, Rudi; Efimov, Igor R.; Dobrzynski, Halina; Boyett, Mark R.
2009-01-01
Because of its complexity, the atrioventricular node (AVN), remains 1 of the least understood regions of the heart. The aim of the study was to construct a detailed anatomic model of the AVN and relate it to AVN function. The electric activity of a rabbit AVN preparation was imaged using voltage-dependent dye. The preparation was then fixed and sectioned. Sixty-five sections at 60- to 340-μm intervals were stained for histology and immunolabeled for neurofilament (marker of nodal tissue) and connexin43 (gap junction protein). This revealed multiple structures within and around the AVN, including transitional tissue, inferior nodal extension, penetrating bundle, His bundle, atrial and ventricular muscle, central fibrous body, tendon of Todaro, and valves. A 3D anatomically detailed mathematical model (≈13 million element array) of the AVN and surrounding atrium and ventricle, incorporating all cell types, was constructed. Comparison of the model with electric activity recorded in experiments suggests that the inferior nodal extension forms the slow pathway, whereas the transitional tissue forms the fast pathway into the AVN. In addition, it suggests the pacemaker activity of the atrioventricular junction originates in the inferior nodal extension. Computer simulation of the propagation of the action potential through the anatomic model shows how, because of the complex structure of the AVN, reentry (slow-fast and fast-slow) can occur. In summary, a mathematical model of the anatomy of the AVN has been generated that allows AVN conduction to be explored. PMID:18309098
Ramírez, A; Gil, M; Martínez Ríos, M A; Cárdenas, M; Pliego, J; Zamora, C; Mata, L A
1982-01-01
Four hundred patients with atrial septal defect treated surgically were reviewed. Thirty five (8.7%) developed arrhytmias post-surgery which persisted for over a year. Sinus bradycardia was found in 10 patients, nodal rhythm in 21, and atrial fibrilation and flutter in 4 patients. Thirty five per cent of the patients with late arrhythmias developed related symptomatology. In 14 patients the function of the sinus node was studied with electrical stimulation of the atrium and with His registry. The interatrial conduction time, AV node and His Purkinje were analized employing various stimulation frequencies. All the cases studied had normal intra-atrial conduction; the response of the atrio-ventricular node to increasing frequencies was normal, an the intraventricular conduction remained constant. In 8 patients (52%), alterations of the sinus node were found; these consisted of prolonged post-stimulation pauses, Wenckebach's type sinoatrial block and suppression of sinus automatism employing vagal procedures or through electrical stimulation. A patient with severe bradycardia detected by dynamic electrocardiography had to be treated with a permanent pacemaker. We confirm that these arrhytmias are not produced by lesions of the internodal tracts, and that an alteration of the sinus node is frequent without a concomitant lesion of the intraventricular pathway. The lesion to the nutrient artery could be due to trauma and/or surgically induced. The response to anticholinergic drugs was good. Prolonged observation of these patients could increase the morbility of these arrythmias and raise doubts of the surgical indications in cases with moderate hemodynamic repercussion.
[Rhythm disorders and cardiac crypto-malformations].
Davy, J M; Raczka, F; Cung, T T; Combes, N; Bortone, A; Gaty, D
2005-12-01
Faced with a cardiac arrhythmia occuring in an apparently healthy heart, it is necessary to perform an anatomical investigation to detect any unsuspected anomalies. Congenital cardiopathy must certainly be excluded, as this is often responsible for rhythm disorders and/or cardiac conduction defects. Similarly, any acquired conditions, cardiomyopathy, or cardiac tumour must be sought. However, the possibility should always be considered of a minimal congenital malformation, which could be repsonsible for: any type of cardiac arrhythmia: rhythm disorder or conduction defect at the atrial, junctional or ventricular level, with a benign or serious prognosis. Unexpected therapeutic difficulties during radiofrequency ablation procedures or at implantation of pacemakers or defibrillators. Together with rhythm studies, the investigation of choice is high quality imaging, either the classic left or right angiography or the more modern cardiac CT or intracardiac mapping.
Notation system and overlay diagrams for the analysis of paced electrocardiograms.
Bernstein, A D; Parsonnet, V
1983-01-01
With the advent of adaptive dual-chamber pacing, the interaction between the pacemaker and the heart is becoming increasingly complex and the interpretation of paced electrocardiograms more difficult. We have developed a set of notation conventions for use in teaching and rhythm-strip analysis. Easily-drawn symbols delineate successful, unsuccessful, and inhibited pacing and sensing events as well as refractory and blanking periods. Another application is to generate movable transparent overlays after programming a pacemaker, to be used in interpreting subsequent rhythm strips.
Differentially Timed Extracellular Signals Synchronize Pacemaker Neuron Clocks
Collins, Ben; Kaplan, Harris S.; Cavey, Matthieu; Lelito, Katherine R.; Bahle, Andrew H.; Zhu, Zhonghua; Macara, Ann Marie; Roman, Gregg; Shafer, Orie T.; Blau, Justin
2014-01-01
Synchronized neuronal activity is vital for complex processes like behavior. Circadian pacemaker neurons offer an unusual opportunity to study synchrony as their molecular clocks oscillate in phase over an extended timeframe (24 h). To identify where, when, and how synchronizing signals are perceived, we first studied the minimal clock neural circuit in Drosophila larvae, manipulating either the four master pacemaker neurons (LNvs) or two dorsal clock neurons (DN1s). Unexpectedly, we found that the PDF Receptor (PdfR) is required in both LNvs and DN1s to maintain synchronized LNv clocks. We also found that glutamate is a second synchronizing signal that is released from DN1s and perceived in LNvs via the metabotropic glutamate receptor (mGluRA). Because simultaneously reducing Pdfr and mGluRA expression in LNvs severely dampened Timeless clock protein oscillations, we conclude that the master pacemaker LNvs require extracellular signals to function normally. These two synchronizing signals are released at opposite times of day and drive cAMP oscillations in LNvs. Finally we found that PdfR and mGluRA also help synchronize Timeless oscillations in adult s-LNvs. We propose that differentially timed signals that drive cAMP oscillations and synchronize pacemaker neurons in circadian neural circuits will be conserved across species. PMID:25268747
Labombarda, Fabien; Hamilton, Robert; Shohoudi, Azadeh; Aboulhosn, Jamil; Broberg, Craig S; Chaix, Marie A; Cohen, Scott; Cook, Stephen; Dore, Annie; Fernandes, Susan M; Fournier, Anne; Kay, Joseph; Macle, Laurent; Mondésert, Blandine; Mongeon, François-Pierre; Opotowsky, Alexander R; Proietti, Anna; Rivard, Lena; Ting, Jennifer; Thibault, Bernard; Zaidi, Ali; Khairy, Paul
2017-08-15
Atrial arrhythmias are the most common complication encountered in the growing and aging population with congenital heart disease. This study sought to assess the types and patterns of atrial arrhythmias, associated factors, and age-related trends. A multicenter cohort study enrolled 482 patients with congenital heart disease and atrial arrhythmias, age 32.0 ± 18.0 years, 45.2% female, from 12 North American centers. Qualifying arrhythmias were classified by a blinded adjudicating committee. The most common presenting arrhythmia was intra-atrial re-entrant tachycardia (IART) (61.6%), followed by atrial fibrillation (28.8%), and focal atrial tachycardia (9.5%). The proportion of arrhythmias due to IART increased with congenital heart disease complexity from 47.2% to 62.1% to 67.0% in patients with simple, moderate, and complex defects, respectively (p = 0.0013). Atrial fibrillation increased with age to surpass IART as the most common arrhythmia in those ≥50 years of age (51.2% vs. 44.2%; p < 0.0001). Older age (odds ratio [OR]: 1.024 per year; 95% confidence interval [CI]: 1.010 to 1.039; p = 0.001) and hypertension (OR: 2.00; 95% CI: 1.08 to 3.71; p = 0.029) were independently associated with atrial fibrillation. During a mean follow-up of 11.3 ± 9.4 years, the predominant arrhythmia pattern was paroxysmal in 62.3%, persistent in 28.2%, and permanent in 9.5%. Permanent atrial arrhythmias increased with age from 3.1% to 22.6% in patients <20 years to ≥50 years, respectively (p < 0.0001). IART is the most common presenting atrial arrhythmia in patients with congenital heart disease, with a predominantly paroxysmal pattern. However, atrial fibrillation increases in prevalence and atrial arrhythmias progressively become permanent as the population ages. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Kula, Elzbieta; Levitan, Edwin S; Pyza, Elzbieta; Rosbash, Michael
2006-04-01
In Drosophila, the neuropeptide pigment-dispersing factor (PDF) is a likely circadian molecule, secreted by central pacemaker neurons (LNvs). PDF is expressed in both small and large LNvs (sLNvs and lLNvs), and there are striking circadian oscillations of PDF staining intensity in the small cell termini, which require a functional molecular clock. This cycling may be relevant to the proposed role of PDF as a synchronizer of the clock system or as an output signal connecting pacemaker cells to locomotor activity centers. In this study, the authors use a generic neuropeptide fusion protein (atrial natriuretic factor-green fluorescent protein [ANF-GFP]) and show that it can be expressed in the same neurons as PDF itself. Yet, ANF-GFP as well as PDF itself does not manifest any cyclical accumulation in sLNv termini in adult transgenic flies. Surprisingly, the absence of detectable PDF cycling is not accompanied by any detectable behavioral pheno-type, since these transgenic flies have normal morning and evening anticipation in a light-dark cycle (LD) and are fully rhythmic in constant darkness (DD). The molecular clock is also not compromised. The results suggest that robust PDF cycling in sLNv termini plays no more than a minor role in the Drosophila circadian system and is apparently not even necessary for clock output function.
Schleich, Jean-Marc; Dillenseger, Jean-Louis; Houyel, Lucile; Almange, Claude; Anderson, Robert H
2009-01-01
Learning embryology remains difficult, since it requires understanding of many complex phenomena. The temporal evolution of developmental events has classically been illustrated using cartoons, which create difficulty in linking spatial and temporal aspects, such correlation being the keystone of descriptive embryology. We synthesized the bibliographic data from recent studies of atrial septal development. On the basis of this synthesis, consensus on the stages of atrial septation as seen in the human heart has been reached by a group of experts in cardiac embryology and pediatric cardiology. This has permitted the preparation of three-dimensional (3D) computer graphic objects for the anatomical components involved in the different stages of normal human atrial septation. We have provided a virtual guide to the process of normal atrial septation, the animation providing an appreciation of the temporal and morphologic events necessary to separate the systemic and pulmonary venous returns. We have shown that our animations of normal human atrial septation increase significantly the teaching of the complex developmental processes involved, and provide a new dynamic for the process of learning.
Lee, Michael S; Nguyen, Heajung; Shlofmitz, Richard
2017-02-01
We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker. The presence of severely calcified coronary lesions can increase the complexity of percutaneous coronary intervention due to the difficulty in advancing and optimally expanding the stent. High-pressure inflations to predilate calcified lesions may cause angiographic complications like perforation and dissection. Suboptimal stent expansion is associated with stent thrombosis and restenosis. Orbital atherectomy safely and effectively modifies calcified plaque to facilitate optimal stent expansion. The incidence of bradycardia in orbital atherectomy is unknown. Fifty consecutive patients underwent orbital atherectomy from February 2014 to September 2016 at our institution, none of whom underwent insertion of a temporary pacemaker. The final analysis included 47 patients in this retrospective study as 3 patients were excluded because of permanent pacemaker implantation. The primary endpoint was significant bradycardia, defined as bradycardia requiring emergent pacemaker placement or a heart rate <50 bpm at the end of atherectomy. The primary endpoint occurred in 4% of all patients, all driven by patients who experienced a heart rate decreasing to <50 bpm. The major adverse cardiac and cerebral event rate was 6%, driven by death (2%) and myocardial infarction (4%). No patient experienced target-vessel revascularization, stroke, or stent thrombosis. Angiographic complications included perforation in 2%, slow-flow in 4%, and flow-limiting dissection in 0%. Significant bradycardia was uncommon during orbital atherectomy. Performing orbital atherectomy without a temporary pacemaker appears to be safe.
Stockburger, Martin; Boveda, Serge; Moreno, Javier; Da Costa, Antoine; Hatala, Robert; Brachmann, Johannes; Butter, Christian; Garcia Seara, Javier; Rolando, Mara; Defaye, Pascal
2015-01-01
Aim Right ventricular pacing (VP) has been hypothesized to increase the risk in heart failure (HF) and atrial fibrillation (AF). The ANSWER study evaluated, whether an AAI-DDD changeover mode to minimize VP (SafeR) improves outcome compared with DDD in a general dual-chamber pacemaker population. Methods and results ANSWER was a randomized controlled multicentre trial assessing SafeR vs. standard DDD in sinus node disease (SND) or AV block (AVB) patients. After a 1-month run-in period, they were randomized (1 : 1) and followed for 3 years. Pre-specified co-primary end-points were VP and the composite of hospitalization for HF, AF, or cardioversion. Pre-specified secondary end-points were cardiac death or HF hospitalizations and cardiovascular hospitalizations. ANSWER enrolled 650 patients (52.0% SND, 48% AVB) at 43 European centres and randomized in SafeR (n = 314) or DDD (n = 318). The SafeR mode showed a significant decrease in VP compared with DDD (11.5 vs. 93.6%, P < 0.0001 at 3 years). Deaths and syncope did not differ between randomization arms. No significant difference between groups [HR = 0.78; 95% CI (0.48–1.25); P = 0.30] was found in the time to event of the co-primary composite of hospitalization for HF, AF, or cardioversion, nor in the individual components. SafeR showed a 51% risk reduction (RR) in experiencing cardiac death or HF hospitalization [HR = 0.49; 95% CI (0.27–0.90); P = 0.02] and 30% RR in experiencing cardiovascular hospitalizations [HR = 0.70; 95% CI (0.49–1.00); P = 0.05]. Conclusion SafeR safely and significantly reduced VP in a general pacemaker population though had no effect on hospitalization for HF, AF, or cardioversion, when compared with DDD. PMID:25179761
Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices.
Nazarian, Saman; Hansford, Rozann; Rahsepar, Amir A; Weltin, Valeria; McVeigh, Diana; Gucuk Ipek, Esra; Kwan, Alan; Berger, Ronald D; Calkins, Hugh; Lardo, Albert C; Kraut, Michael A; Kamel, Ihab R; Zimmerman, Stefan L; Halperin, Henry R
2017-12-28
Patients who have pacemakers or defibrillators are often denied the opportunity to undergo magnetic resonance imaging (MRI) because of safety concerns, unless the devices meet certain criteria specified by the Food and Drug Administration (termed "MRI-conditional" devices). We performed a prospective, nonrandomized study to assess the safety of MRI at a magnetic field strength of 1.5 Tesla in 1509 patients who had a pacemaker (58%) or an implantable cardioverter-defibrillator (42%) that was not considered to be MRI-conditional (termed a "legacy" device). Overall, the patients underwent 2103 thoracic and nonthoracic MRI examinations that were deemed to be clinically necessary. The pacing mode was changed to asynchronous mode for pacing-dependent patients and to demand mode for other patients. Tachyarrhythmia functions were disabled. Outcome assessments included adverse events and changes in the variables that indicate lead and generator function and interaction with surrounding tissue (device parameters). No long-term clinically significant adverse events were reported. In nine MRI examinations (0.4%; 95% confidence interval, 0.2 to 0.7), the patient's device reset to a backup mode. The reset was transient in eight of the nine examinations. In one case, a pacemaker with less than 1 month left of battery life reset to ventricular inhibited pacing and could not be reprogrammed; the device was subsequently replaced. The most common notable change in device parameters (>50% change from baseline) immediately after MRI was a decrease in P-wave amplitude, which occurred in 1% of the patients. At long-term follow-up (results of which were available for 63% of the patients), the most common notable changes from baseline were decreases in P-wave amplitude (in 4% of the patients), increases in atrial capture threshold (4%), increases in right ventricular capture threshold (4%), and increases in left ventricular capture threshold (3%). The observed changes in lead parameters were not clinically significant and did not require device revision or reprogramming. We evaluated the safety of MRI, performed with the use of a prespecified safety protocol, in 1509 patients who had a legacy pacemaker or a legacy implantable cardioverter-defibrillator system. No long-term clinically significant adverse events were reported. (Funded by Johns Hopkins University and the National Institutes of Health; ClinicalTrials.gov number, NCT01130896 .).
Zhang, Youhua; Popović, Zoran B; Kusunose, Kenya; Mazgalev, Todor N
2013-01-01
Atrial fibrillation (AF) and heart failure (HF) frequently coexist. We have previously demonstrated that selective atrioventricular node (AVN) vagal stimulation (AVN-VS) can be used to control ventricular rate during AF. Due to withdrawal of vagal activity in HF, the therapeutic effects of AVN-VS may be compromised in the combined condition of AF and HF. Accordingly, this study was designed to evaluate the therapeutic effects of AVN-VS to control ventricular rate in AF and HF. A combined model of AF and HF was created by implanting a dual chamber pacemaker in 24 dogs. A newly designed bipolar electrode was inserted into the ganglionic AVN fat pad and connected to a nerve stimulator for delivering AVN-VS. In all dogs, HF was induced by high rate ventricular pacing at 220 bpm for 4 weeks. AF was then induced and maintained by rapid atrial pacing at 600 bpm after discontinuation of ventricular pacing. These HF + AF dogs were randomized into control (n = 9) and AVN-VS (n = 15) groups. In the latter group, vagal stimulation (310 μs, 20 Hz, 3-7 mA) was delivered continuously for 6 months. Compared with the control, AVN-VS had a consistent effect on ventricular rate slowing (by >50 bpm, all P < 0.001) during the entire 6-month observation period that was associated with left ventricular functional improvement. Moreover, AVN-VS was well tolerated by the treated animals. AVN-VS achieved consistent rate slowing, which was associated with improved ventricular function in a canine AF and HF model. Thus, AVN-VS may be a novel, effective therapeutic option in the combined condition of AF and HF. © 2012 Wiley Periodicals, Inc.
Rao, Hygriv B; Saksena, Sanjeev
2005-08-01
Hybrid therapy strategies have combined antiarrhythmic drugs (AAD) with pacemakers, atrio-ventricular defibrillators (AV ICD) or atrial ablation individually. The feasibility combining AAD with dual site RA pacing (DAP) in an AV ICD has not been examined. We used an AV ICD with a novel lead configuration permitting DAP, antitachycardia pacing (ATP) or atrial shocks (ADF) in patients (pts) with refractory persistent or permanent AF. Hybrid therapy included linear RA ablation and/or focal ablation. Continuous DAP and automatic ATP with patient or physician activated ADF. 24 pts, mean age 66 +/- 10 yrs, with cardiac disease (22 pts), underwent insertion of an AVICD with dual RA leads. 20 patients had concomitant ablative procedures (RA only = 19, RA + LA = 1) and all pts continued previously ineffective AAD. During a follow-up of 2-36 months (mean 17 +/- 8 mos), rhythm control was restored in all pts & maintained long-term in 19 (83%) pts. 8 pts used AF termination therapies successfully. Device datalogs showed no episodes of AF in 6 pts, asymptomatic brief arrhythmias in 4 pts, infrequent paroxysmal AF in 9 pts & persistent AF recurred in 5 pts. AV ICD detection algorithms reliably detected AF or AT in the DAP mode in all pts. Intermittent brief P wave double counting occurred during AT in selected pts. No pt received inappropriate ADF therapy. 1. DAP can be safely incorporated in an AVICD devices for use in an hybrid therapy strategy for AF pts. 2. These devices can be effective for both AF prevention & termination. 3. Long term rhythm control can be achieved and documented by device datalogs in persistent and permanent AF.
Circadian clocks in symbiotic corals: the duet between Symbiodinium algae and their coral host.
Sorek, Michal; Díaz-Almeyda, Erika M; Medina, Mónica; Levy, Oren
2014-04-01
To date, the association and synchronization between two organismal circadian clocks ticking in parallel as part of a meta-organism (termed a symbiotic association), have rarely been investigated. Reef-building corals exhibit complex rhythmic responses to diurnal, lunar, and annual changes. Understanding circadian, circatidal, and annual regulation in reef-building corals is complicated by the presence of photosynthetic endosymbionts, which have a profound physiochemical influence on the intracellular environment. How corals tune their animal-based clock machinery to respond to external cues while simultaneously responding to internal physiological changes imposed by the symbiont, is not clear. There is insufficient molecular or physiological evidence of the existence of a circadian pacemaker that controls the metabolism, photosynthesis, synchronized mass spawning, and calcification processes in symbiotic corals. In this review, we present current knowledge regarding the animal pacemaker and the symbiotic-algal pacemaker. We examine the evidence from behavioral, physiological, molecular, and evolutionary perspectives. We explain why symbiotic corals are an interesting model with which to study the complexities and evolution of the metazoan circadian clock. We also provide evidence of why the chronobiology of corals is fundamental and extremely important for explaining the biology, physiology, and metabolism of coral reefs. A deeper understanding of these complex issues can help explain coral mass spawning, one of the earth's greatest and most mysterious behavioral phenomena. Copyright © 2014 Elsevier B.V. All rights reserved.
Runtime Verification of Pacemaker Functionality Using Hierarchical Fuzzy Colored Petri-nets.
Majma, Negar; Babamir, Seyed Morteza; Monadjemi, Amirhassan
2017-02-01
Today, implanted medical devices are increasingly used for many patients and in case of diverse health problems. However, several runtime problems and errors are reported by the relevant organizations, even resulting in patient death. One of those devices is the pacemaker. The pacemaker is a device helping the patient to regulate the heartbeat by connecting to the cardiac vessels. This device is directed by its software, so any failure in this software causes a serious malfunction. Therefore, this study aims to a better way to monitor the device's software behavior to decrease the failure risk. Accordingly, we supervise the runtime function and status of the software. The software verification means examining limitations and needs of the system users by the system running software. In this paper, a method to verify the pacemaker software, based on the fuzzy function of the device, is presented. So, the function limitations of the device are identified and presented as fuzzy rules and then the device is verified based on the hierarchical Fuzzy Colored Petri-net (FCPN), which is formed considering the software limits. Regarding the experiences of using: 1) Fuzzy Petri-nets (FPN) to verify insulin pumps, 2) Colored Petri-nets (CPN) to verify the pacemaker and 3) To verify the pacemaker by a software agent with Petri-network based knowledge, which we gained during the previous studies, the runtime behavior of the pacemaker software is examined by HFCPN, in this paper. This is considered a developing step compared to the earlier work. HFCPN in this paper, compared to the FPN and CPN used in our previous studies reduces the complexity. By presenting the Petri-net (PN) in a hierarchical form, the verification runtime, decreased as 90.61% compared to the verification runtime in the earlier work. Since we need an inference engine in the runtime verification, we used the HFCPN to enhance the performance of the inference engine.
Schleich, Jean-Marc; Dillenseger, Jean-Louis; Houyel, Lucile; Almange, Claude; Anderson, Robert H.
2009-01-01
Background Learning embryology remains difficult, since it requires understanding of many complex phenomena. The temporal evolution of developmental events has classically been illustrated using cartoons, which create difficulty in linking spatial and temporal aspects, such correlation being the keystone of descriptive embryology. Methods We synthesized the bibliographic data from recent studies of atrial septal development. On the basis of this synthesis, consensus on the stages of atrial septation as seen in the human heart has been reached by a group of experts in cardiac embryology and paediatric cardiology. This has permitted the preparation of three-dimensional (3-D) computer graphic objects for the anatomical components involved in the different stages of normal human atrial septation. Results We have provided a virtual guide to the process of normal atrial septation, the animation providing an appreciation of the temporal and morphologic events necessary to separate the systemic and pulmonary venous returns. Conclusion We have shown that our animations of normal human atrial septation increase significantly the teaching of the complex developmental processes involved, and provide a new dynamic for the process of learning. PMID:19363807
Left Atrial Appendage Closure for Stroke Prevention: Devices, Techniques, and Efficacy.
Iskandar, Sandia; Vacek, James; Lavu, Madhav; Lakkireddy, Dhanunjaya
2016-05-01
Left atrial appendage closure can be performed either surgically or percutaneously. Surgical approaches include direct suture, excision and suture, stapling, and clipping. Percutaneous approaches include endocardial, epicardial, and hybrid endocardial-epicardial techniques. Left atrial appendage anatomy is highly variable and complex; therefore, preprocedural imaging is crucial to determine device selection and sizing, which contribute to procedural success and reduction of complications. Currently, the WATCHMAN is the only device that is approved for left atrial appendage closure in the United States. Copyright © 2016 Elsevier Inc. All rights reserved.
Measuring dose from radiotherapy treatments in the vicinity of a cardiac pacemaker.
Peet, Samuel C; Wilks, Rachael; Kairn, Tanya; Crowe, Scott B
2016-12-01
This study investigated the dose absorbed by tissues surrounding artificial cardiac pacemakers during external beam radiotherapy procedures. The usefulness of out-of-field reference data, treatment planning systems, and skin dose measurements to estimate the dose in the vicinity of a pacemaker was also examined. Measurements were performed by installing a pacemaker onto an anthropomorphic phantom, and using radiochromic film and optically stimulated luminescence dosimeters to measure the dose in the vicinity of the device during the delivery of square fields and clinical treatment plans. It was found that the dose delivered in the vicinity of the cardiac device was unevenly distributed both laterally and anteroposteriorly. As the device was moved distally from the square field, the dose dropped exponentially, in line with out-of-field reference data in the literature. Treatment planning systems were found to substantially underestimate the dose for volumetric modulated arc therapy, helical tomotherapy, and 3D conformal treatments. The skin dose was observed to be either greater or lesser than the dose received at the depth of the device, depending on the treatment site, and so care should be if skin dose measurements are to be used to estimate the dose to a pacemaker. Square field reference data may be used as an upper estimate of absorbed dose per monitor unit in the vicinity of a cardiac device for complex treatments involving multiple gantry angles. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.
Candinas, R; Duru, F; Schneider, J; Lüscher, T F; Stokes, K
1999-02-01
To analyze the site and thickness of encapsulation around ventricular endocardial pacing leads and the extent of tricuspid valve adhesion, from today's perspective, with implications for lead removal and sensor location. Gross cardiac postmortem analysis was performed in 11 cases (8 female and 3 male patients; mean age, 78+/-7 years). None of the patients had died because of pacemaker malfunction. The mean implant time was 61+/-60 months (range, 4 to 184). The observations ranged from encapsulation only at the tip of the pacing lead to complete encapsulation along the entire length of the pacing lead within the right ventricle. Substantial areas of adhesion at the tricuspid valve apparatus were noted in 7 of the 11 cases (64%). The firmly attached leads could be removed only by dissection, and in some cases, removal was possible only by damaging the associated structures. No specific optimal site for sensor placement could be identified along the ventricular portion of the pacing leads; however, the fibrotic response was relatively less prominent in the atrial chamber. Extensive encapsulation is present in most long-term pacemaker leads, which may complicate lead removal. The site and thickness of encapsulation seem to be highly variable. Tricuspid valve adhesion, which is usually underestimated, may be severe. In contrast to earlier reports, our study demonstrates that the extent of fibrotic encapsulation may not be related to the duration since lead implantation. Moreover, we noted no ideal encapsulation-free site for sensors on the ventricular portion of long-term pacing leads.
Albarado-Ibañez, Alondra; Avelino-Cruz, José Everardo; Velasco, Myrian; Torres-Jácome, Julián; Hiriart, Marcia
2013-01-01
In the last ten years, the incidences of metabolic syndrome and supraventricular arrhythmias have greatly increased. The metabolic syndrome is a cluster of alterations, which include obesity, hypertension, hypertriglyceridemia, glucose intolerance and insulin resistance, that increase the risk of developing, among others, atrial and nodal arrhythmias. The aim of this study is to demonstrate that metabolic syndrome induces electrical remodeling of the sinus node and produces arrhythmias. We induced metabolic syndrome in 2-month-old male Wistar rats by administering 20% sucrose in the drinking water. Eight weeks later, the rats were anesthetized and the electrocardiogram was recorded, revealing the presence of arrhythmias only in treated rats. Using conventional microelectrode and voltage clamp techniques, we analyzed the electrical activity of the sinoatrial node. We observed that in the sinoatrial node of “metabolic syndrome rats”, compared to controls, the spontaneous firing of all cells decreased, while the slope of the diastolic depolarization increased only in latent pacemaker cells. Accordingly, the pacemaker currents If and Ist increased. Furthermore, histological analysis showed a large amount of fat surrounding nodal cardiomyocytes and a rise in the sympathetic innervation. Finally, Poincaré plot denoted irregularity in the R-R and P-P ECG intervals, in agreement with the variability of nodal firing potential recorded in metabolic syndrome rats. We conclude that metabolic syndrome produces a dysfunction SA node by disrupting normal architecture and the electrical activity, which could explain the onset of arrhythmias in rats. PMID:24250786
Wang, Yue Yi; Mesirca, Pietro; Marqués-Sulé, Elena; Villejoubert, Olivier; D’Ocon, Pilar; Ruiz, Cristina; Domingo, Diana; Zorio, Esther; Mangoni, Matteo E.; Benitah, Jean-Pierre; Gómez, Ana María
2017-01-01
Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a lethal genetic arrhythmia that manifests syncope or sudden death in children and young adults under stress conditions. CPVT patients often present bradycardia and sino-atrial node (SAN) dysfunction. However, the mechanism remains unclear. We analyzed SAN function in two CPVT families and in a novel knock-in (KI) mouse model carrying the RyR2R420Q mutation. Humans and KI mice presented slower resting heart rate. Accordingly, the rate of spontaneous intracellular Ca2+ ([Ca2+]i) transients was slower in KI mouse SAN preparations than in WT, without any significant alteration in the “funny” current (If ). The L-type Ca2+ current was reduced in KI SAN cells in a [Ca2+]i-dependent way, suggesting that bradycardia was due to disrupted crosstalk between the “voltage” and “Ca2+” clock, and the mechanisms of pacemaking was induced by aberrant spontaneous RyR2- dependent Ca2+ release. This finding was consistent with a higher Ca2+ leak during diastolic periods produced by long-lasting Ca2+ sparks in KI SAN cells. Our results uncover a mechanism for the CPVT-causing RyR2 N-terminal mutation R420Q, and they highlight the fact that enhancing the Ca2+ clock may slow the heart rhythm by disturbing the coupling between Ca2+ and voltage clocks. PMID:28422759
Mairesse, Georges H; Braunschweig, Frieder; Klersy, Katherine; Cowie, Martin R; Leyva, Francisco
2015-05-01
Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) permits early detection of arrhythmias, device, and lead failure and may also be useful in risk-predicting patient-related outcomes. Financial benefits for patients and healthcare organizations have also been shown. We sought to assess the implementation and funding of RM of CIEDs, including conventional pacemakers (PMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices in Europe. Electronic survey from 43 centres in 15 European countries. In the study sample, RM was available in 22% of PM patients, 74% of ICD patients, and 69% of CRT patients. The most significant perceived benefits were the early detection of atrial arrhythmias in pacemaker patients, lead failure in ICD patients, and worsening heart failure in CRT patients. Remote monitoring was reported to lead a reduction of in-office follow-ups for all devices. The most important reported barrier to the implementation of RM for all CIEDs was lack of reimbursement (80% of centres). Physicians regard RM of CIEDs as a clinically useful technology that affords significant benefits for patients and healthcare organizations. Remote monitoring, however, is perceived as increasing workload. Reimbursement for RM is generally perceived as a major barrier to implementation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Albarado-Ibañez, Alondra; Avelino-Cruz, José Everardo; Velasco, Myrian; Torres-Jácome, Julián; Hiriart, Marcia
2013-01-01
In the last ten years, the incidences of metabolic syndrome and supraventricular arrhythmias have greatly increased. The metabolic syndrome is a cluster of alterations, which include obesity, hypertension, hypertriglyceridemia, glucose intolerance and insulin resistance, that increase the risk of developing, among others, atrial and nodal arrhythmias. The aim of this study is to demonstrate that metabolic syndrome induces electrical remodeling of the sinus node and produces arrhythmias. We induced metabolic syndrome in 2-month-old male Wistar rats by administering 20% sucrose in the drinking water. Eight weeks later, the rats were anesthetized and the electrocardiogram was recorded, revealing the presence of arrhythmias only in treated rats. Using conventional microelectrode and voltage clamp techniques, we analyzed the electrical activity of the sinoatrial node. We observed that in the sinoatrial node of "metabolic syndrome rats", compared to controls, the spontaneous firing of all cells decreased, while the slope of the diastolic depolarization increased only in latent pacemaker cells. Accordingly, the pacemaker currents If and Ist increased. Furthermore, histological analysis showed a large amount of fat surrounding nodal cardiomyocytes and a rise in the sympathetic innervation. Finally, Poincaré plot denoted irregularity in the R-R and P-P ECG intervals, in agreement with the variability of nodal firing potential recorded in metabolic syndrome rats. We conclude that metabolic syndrome produces a dysfunction SA node by disrupting normal architecture and the electrical activity, which could explain the onset of arrhythmias in rats.
History of surgery for atrial fibrillation.
Edgerton, Zachary J; Edgerton, James R
2009-12-01
There is a rich history of surgery for atrial fibrillation. Initial procedures were aimed at controlling the ventricular response rate. Later procedures were directed at converting atrial fibrillation to normal sinus rhythm. These culminated in the Cox Maze III procedure. While highly effective, the complexity and morbidity of the cut and sew Maze III limited its adoption. Enabling technology has developed alternate energy sources designed to produce a transmural atrial scar without cutting and sewing. Termed the Maze IV, this lessened the morbidity of the procedure and widened the applicability. Further advances in minimal access techniques are now being developed to allow totally thorascopic placement of all the left atrial lesions on the full, beating heart, using alternate energy sources.
Genetics Home Reference: Carney complex
... addition, some affected individuals have at least one blue-black mole called a blue nevus. Related Information What does it mean if ... Carney Syndrome LAMB - Lentigines, atrial myxoma, mucocutaneous myoma, blue nevus syndrome NAME - Nevi, atrial myxoma, skin myxoma, ...
Wiesel, Joseph; Salomone, Thomas J
2017-10-15
Early detection of asymptomatic atrial fibrillation (AF) provides an opportunity to treat patients to reduce their risk of stroke. Long-term residents of skilled nursing facilities frequently have multiple risk factors for strokes due to AF and may benefit from screening for AF. Patients in a skilled nursing facility 65 years and older, without a history of AF and without a pacemaker or defibrillator, were evaluated using a Microlife WatchBP Home A automatic blood pressure monitor that can detect AF when set to a triple reading mode. Those with readings positive for AF were evaluated with a standard 12-lead electrocardiogram (ECG) or a 30-second single-channel ECG to confirm the presence of AF. A total of 101 patients were screened with an average age of 78 years, and 48 (48%) were female. Nine automatic blood pressure monitor readings were positive for possible AF. Of those, 7 (6.9%, 95% confidence intervals 3.0% to 14.2%) had AF confirmed with ECG. Only 2 (2%, 95% confidence interval 0.3% to 7.7%) were false-positive readings. One-time screening for AF using an automatic blood pressure monitor in a skilled nursing facility resulted in a high number of patients with newly diagnosed AF. Copyright © 2017 Elsevier Inc. All rights reserved.
Thoracic robotics at the Heart Hospital Baylor Plano: the first 20 cases
2012-01-01
A da Vinci Robotic Surgical System was purchased for The Heart Hospital Baylor Plano in fall 2011 and a program for robotic-assisted thoracic surgery commenced at the facility. Successive thoracic patients were offered and accepted a robotic-assisted operation. No patient was excluded because of age, height, weight, or comorbidities. The first 20 patients are summarized herein. Of the first 10 operations, only one was a lobectomy. As the program staff gained experience, seven of the latter 10 procedures were lobectomies. The average length of stay was 2.6 days (longest, 4 days). The average operating room time was 147 minutes overall and 200 minutes for lobectomies. The longest operating room time was 337 minutes in a patient who underwent a right middle lobectomy that was converted to a video-assisted thoracic surgery. Two patients developed atrial fibrillation, one of whom had a pacemaker and a history of paroxysmal atrial fibrillation. One patient developed a bronchopleural fistula on the first postoperative day, following a coughing episode. One patient was readmitted 6 days after hospital discharge with a pneumothorax, which was successfully treated with a small-bore catheter. In conclusion, robotic-assisted thoracic surgery has many advantages. Decreased complications can lead to improved outcomes, and hospitals can achieve cost savings as a result of reduced length of stay. PMID:23077378
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xiao-qing; Liu, Xu, E-mail: xkliuxu@126.com; Wang, Quan-xing, E-mail: wqxejd@126.com
2015-01-01
The exact mechanisms underlying inhibitory effects of pioglitazone (Pio) on Angiotensin II (AngII)-induced atrial fibrosis are complex and remain largely unknown. In the present study, we examined the effect of Pio on AngII-induced mice atrial fibrosis in vivo and atrial fibroblasts proliferation in vitro. In vivo study showed that AngII infusion induced atrial fibrosis and increased expressions of Toll/IL-1 receptor domain-containing adaptor inducing IFN-β (TRIF) and tumor necrosis factor receptor associated factor 6 (TRAF6) in mice models. However, those effects could be attenuated by Pio (P<0.01). As for in vitro experiment, Pio suppressed AngII-induced atrial fibroblasts proliferation via nuclear factor-κB/transformingmore » growth factor-β1/TRIF/TRAF6 signaling pathway in primary cultured mice atrial fibroblasts (P<0.01). In conclusion, suppression of Pio on AngII-induced atrial fibrosis might be related to its inhibitory effects on above signaling pathway. - Highlights: • Angiotensin II increased atrial fibrosis and related gene expressions in mice. • Angiotensin II induced atrial fibroblasts proliferation by activating signaling pathway. • Pioglitazone reversed both aforementioned changes.« less
Doughan, Abdul Rahman K; McConnell, Michael E; Book, Wendy M
2007-03-01
This study evaluated the effects of beta blockers (carvedilol and metoprolol XL) on New York Heart Association functional class and systemic right ventricular (RV) function in patients with complete transposition of the great arteries who had systemic RV dysfunction late after atrial inflow correction. A significant improvement in New York Heart Association functional class was found after 4 months of therapy with beta blockers. Functional recovery was significant mostly in those patients with pacemakers who received higher maintenance doses of carvedilol. RV end-diastolic area was significantly greater in untreated patients at the end of the follow-up period, whereas it was unchanged in treated patients. In conclusion, beta blockers prevent RV remodeling, with a concomitant improvement in exercise tolerance in patients with complete transposition of the great arteries and systemic RV dysfunction.
Nakamura, R K; Russell, N J; Shelton, G D
2012-06-01
A nine-year-old neutered female mixed breed dog presented for evaluation following a five-day history of lethargy, inappetence, weakness, abdominal distension and generalised muscle atrophy. Persistent vatrial standstill with a junctional rhythm was identified on electrocardiogram. Echocardiogram identified moderate dilation of all cardiac chambers and mild thickening of the mitral and tricuspid valves. Serology was negative for Neospora caninum and Toxoplasma gondii. Permanent pacemaker implantation was performed in addition to endomyocardial and skeletal muscle biopsies. Cryosections from the biceps femoris muscle showed numerous nemaline rod bodies while endomyocardial biopsies were possibly consistent with end-stage myocarditis. Rod bodies have rarely been reported in the veterinary literature. To the authors' knowledge, this is the first report of adult-onset nemaline rod myopathy and hypothyroidism with concurrent cardiac disease in a dog. © 2012 British Small Animal Veterinary Association.
NASA Astrophysics Data System (ADS)
Ojeda, David; Le Rolle, Virginie; Tse Ve Koon, Kevin; Thebault, Christophe; Donal, Erwan; Hernández, Alfredo I.
2013-11-01
In this paper, lumped-parameter models of the cardiovascular system, the cardiac electrical conduction system and a pacemaker are coupled to generate mitral ow pro les for di erent atrio-ventricular delay (AVD) con gurations, in the context of cardiac resynchronization therapy (CRT). First, we perform a local sensitivity analysis of left ventricular and left atrial parameters on mitral ow characteristics, namely E and A wave amplitude, mitral ow duration, and mitral ow time integral. Additionally, a global sensitivity analysis over all model parameters is presented to screen for the most relevant parameters that a ect the same mitral ow characteristics. Results provide insight on the in uence of left ventricle and atrium in uence on mitral ow pro les. This information will be useful for future parameter estimation of the model that could reproduce the mitral ow pro les and cardiovascular hemodynamics of patients undergoing AVD optimization during CRT.
Initial dynamics of the EKG during an electrical defibrillation of the heart
NASA Technical Reports Server (NTRS)
Bikov, I. I.; Chebotarov, Y. P.; Nikolaev, V. G.
1980-01-01
In tests on 11 mature dogs, immobilized by means of an automatic blocking and synchronization system, artefact free EKG were obtained, beginning 0.04-0.06 sec after passage of a defibrillating current. Different versions of the start of fibrillation were noted, in application of the defibrillating stimulus in the early phase of the cardiac cycle. A swinging phenomenon, increasing amplitude, of fibrillation was noted for 0.4-1.5 sec after delivery of a subthreshold stimulus. Conditions for a positive outcome of repeated defibrillation were found, and a relationship was noted between the configuration of the exciting process with respect to the lines of force of the defibrillating current and the defibrillation threshold. It was shown that the initial EKG dynamics after defibrillation is based on a gradual shift of the pacemaker from the myocardium of the ventricles to the sinus node, through phases of atrioventricular and atrial automatism.
Validation of a novel mapping system and utility for mapping complex atrial tachycardias.
Honarbakhsh, S; Hunter, R J; Dhillon, G; Ullah, W; Keating, E; Providencia, R; Chow, A; Earley, M J; Schilling, R J
2018-03-01
This study sought to validate a novel wavefront mapping system utilizing whole-chamber basket catheters (CARTOFINDER, Biosense Webster). The system was validated in terms of (1) mapping atrial-paced beats and (2) mapping complex wavefront patterns in atrial tachycardia (AT). Patients undergoing catheter ablation for AT and persistent AF were included. A 64-pole-basket catheter was used to acquire unipolar signals that were processed by CARTOFINDER mapping system to generate dynamic wavefront propagation maps. The left atrium was paced from four sites to demonstrate focal activation. ATs were mapped with the mechanism confirmed by conventional mapping, entrainment, and response to ablation. Twenty-two patients were included in the study (16 with AT and 6 with AF initially who terminated to AT during ablation). In total, 172 maps were created with the mapping system. It correctly identified atrial-pacing sites in all paced maps. It accurately mapped 9 focal/microreentrant and 18 macroreentrant ATs both in the left and right atrium. A third and fourth observer independently identified the sites of atrial pacing and the AT mechanism from the CARTOFINDER maps, while being blinded to the conventional activation maps. This novel mapping system was effectively validated by mapping focal activation patterns from atrial-paced beats. The system was also effective in mapping complex wavefront patterns in a range of ATs in patients with scarred atria. The system may therefore be of practical use in the mapping and ablation of AT and could have potential for mapping wavefront activations in AF. © 2018 Wiley Periodicals, Inc.
Atrial flutter with 1:1 conduction in undiagnosed Wolff-Parkinson-White syndrome.
Nelson, Jessie G; Zhu, Dennis W
2014-05-01
Atrial flutter with 1:1 atrioventricular conduction via an accessory pathway is an uncommon presentation of Wolff-Parkinson-White syndrome not previously reported in the emergency medicine literature. Wolff-Parkinson-White syndrome, a form of ventricular preexcitation sometimes initially seen and diagnosed in the emergency department (ED), can present with varied tachydysrhythmias for which certain treatments are contraindicated. For instance, atrial fibrillation with preexcited conduction needs specific consideration of medication choice to avoid potential degeneration into ventricular fibrillation. We describe an adult female presenting with a very rapid, regular wide complex tachycardia successfully cardioverted in the ED followed by a normal electrocardiogram (ECG). Electrophysiology study confirmed atrial flutter with 1:1 conduction and revealed an accessory pathway consistent with Wolff-Parkinson-White syndrome, despite lack of ECG findings of preexcitation during sinus rhythm. Why should an emergency physician be aware of this? Ventricular tachycardia must be the first consideration in patients with regular wide complex tachycardia. However, clinicians should consider atrial flutter with 1:1 conduction related to an accessory pathway when treating patients with the triad of very rapid rate (>250 beats/min), wide QRS complex, and regular rhythm, especially when considering pharmacologic treatment. Emergency physicians also should be aware of electrocardiographically concealed accessory pathways, and that lack of delta waves does not rule out preexcitation syndromes such as Wolff-Parkinson-White syndrome. Copyright © 2014 Elsevier Inc. All rights reserved.
Cor triatriatum dexter associated with atrial septal defect: Management in a complex clinical case.
Sozzi, Fabiola B; Montanaro, Claudia; Bacà, Laura; Viani, Giacomo M; Zilocchi, Massimo; Canetta, Ciro; Meazza, Roberto; Pavone, Laura; Lombardi, Federico
2017-11-01
The coexistence of an atrial septal defect and a prominent eustachian valve is a rare congenital anomaly, rarely reported in literature. Differentiation between a giant eustachian valve and cor triatriatum dexter can be difficult. A case of a large atrial septal defect associated with cor triatriatum dexter diagnosed by echocardiography in an asymptomatic woman is reported. A watchful waiting strategy was adopted. © 2017, Wiley Periodicals, Inc.
Chevalier, Marc; De Sa, Rafaël; Cardoit, Laura; Thoby-Brisson, Muriel
2016-01-01
Breathing is a rhythmic behavior that requires organized contractions of respiratory effector muscles. This behavior must adapt to constantly changing conditions in order to ensure homeostasis, proper body oxygenation, and CO2/pH regulation. Respiratory rhythmogenesis is controlled by neural networks located in the brainstem. One area considered to be essential for generating the inspiratory phase of the respiratory rhythm is the preBötzinger complex (preBötC). Rhythmogenesis emerges from this network through the interplay between the activation of intrinsic cellular properties (pacemaker properties) and intercellular synaptic connections. Respiratory activity continuously changes under the impact of numerous modulatory substances depending on organismal needs and environmental conditions. The preBötC network has been shown to become active during the last third of gestation. But only little is known regarding the modulation of inspiratory rhythmicity at embryonic stages and even less on a possible role of pacemaker neurons in this functional flexibility during the prenatal period. By combining electrophysiology and calcium imaging performed on embryonic brainstem slice preparations, we provide evidence showing that embryonic inspiratory pacemaker neurons are already intrinsically sensitive to neuromodulation and external conditions (i.e., temperature) affecting respiratory network activity, suggesting a potential role of pacemaker neurons in mediating rhythm adaptation to modulatory stimuli in the embryo.
Chevalier, Marc; De Sa, Rafaël; Cardoit, Laura; Thoby-Brisson, Muriel
2016-01-01
Breathing is a rhythmic behavior that requires organized contractions of respiratory effector muscles. This behavior must adapt to constantly changing conditions in order to ensure homeostasis, proper body oxygenation, and CO2/pH regulation. Respiratory rhythmogenesis is controlled by neural networks located in the brainstem. One area considered to be essential for generating the inspiratory phase of the respiratory rhythm is the preBötzinger complex (preBötC). Rhythmogenesis emerges from this network through the interplay between the activation of intrinsic cellular properties (pacemaker properties) and intercellular synaptic connections. Respiratory activity continuously changes under the impact of numerous modulatory substances depending on organismal needs and environmental conditions. The preBötC network has been shown to become active during the last third of gestation. But only little is known regarding the modulation of inspiratory rhythmicity at embryonic stages and even less on a possible role of pacemaker neurons in this functional flexibility during the prenatal period. By combining electrophysiology and calcium imaging performed on embryonic brainstem slice preparations, we provide evidence showing that embryonic inspiratory pacemaker neurons are already intrinsically sensitive to neuromodulation and external conditions (i.e., temperature) affecting respiratory network activity, suggesting a potential role of pacemaker neurons in mediating rhythm adaptation to modulatory stimuli in the embryo. PMID:27239348
Masoli, Stefano; Solinas, Sergio; D'Angelo, Egidio
2015-01-01
The Purkinje cell (PC) is among the most complex neurons in the brain and plays a critical role for cerebellar functioning. PCs operate as fast pacemakers modulated by synaptic inputs but can switch from simple spikes to complex bursts and, in some conditions, show bistability. In contrast to original works emphasizing dendritic Ca-dependent mechanisms, recent experiments have supported a primary role for axonal Na-dependent processing, which could effectively regulate spike generation and transmission to deep cerebellar nuclei (DCN). In order to account for the numerous ionic mechanisms involved (at present including Nav1.6, Cav2.1, Cav3.1, Cav3.2, Cav3.3, Kv1.1, Kv1.5, Kv3.3, Kv3.4, Kv4.3, KCa1.1, KCa2.2, KCa3.1, Kir2.x, HCN1), we have elaborated a multicompartmental model incorporating available knowledge on localization and gating of PC ionic channels. The axon, including initial segment (AIS) and Ranvier nodes (RNs), proved critical to obtain appropriate pacemaking and firing frequency modulation. Simple spikes initiated in the AIS and protracted discharges were stabilized in the soma through Na-dependent mechanisms, while somato-dendritic Ca channels contributed to sustain pacemaking and to generate complex bursting at high discharge regimes. Bistability occurred only following Na and Ca channel down-regulation. In addition, specific properties in RNs K currents were required to limit spike transmission frequency along the axon. The model showed how organized electroresponsive functions could emerge from the molecular complexity of PCs and showed that the axon is fundamental to complement ionic channel compartmentalization enabling action potential processing and transmission of specific spike patterns to DCN. PMID:25759640
Fink, Thomas; Schlüter, Michael; Heeger, Christian-Hendrik; Lemes, Christine; Maurer, Tilman; Reissmann, Bruno; Riedl, Johannes; Rottner, Laura; Santoro, Francesco; Schmidt, Boris; Wohlmuth, Peter; Mathew, Shibu; Sohns, Christian; Ouyang, Feifan; Metzner, Andreas; Kuck, Karl-Heinz
2017-07-01
Pulmonary vein isolation (PVI) for persistent atrial fibrillation is associated with limited success rates and often requires multiple procedures to maintain stable sinus rhythm. In the prospective and randomized Alster-Lost-AF trial (Ablation at St. Georg Hospital for Long-Standing Persistent Atrial Fibrillation), we sought to assess, in patients with symptomatic persistent or long-standing persistent atrial fibrillation, the outcomes of initial ablative strategies comprising either stand-alone PVI (PVI-only approach) or a stepwise approach of PVI followed by complex fractionated atrial electrogram ablation and linear ablation (Substrate-modification approach). Patients were randomized 1:1 to stand-alone PVI or PVI plus substrate modification. The primary study end point was freedom from recurrence of any atrial tachyarrhythmia, outside a 90-day blanking period, at 12 months. A total of 124 patients were enrolled, with 118 patients included in the analysis (61 in the PVI-only group, 57 in the Substrate-modification group). Atrial tachyarrhythmias recurred in 28 PVI-only group patients and 24 Substrate-modification group patients, for 1-year freedom from tachyarrhythmia recurrence after a single ablation procedure of 54% (95% confidence interval, 43%-68%) in the PVI-only and 57% (95% confidence interval, 46%-72%) in the Substrate-modification group ( P =0.86). Twenty-four patients in the PVI-only group (39%) and 18 in the Substrate-modification group (32%) were without arrhythmia recurrence and off antiarrhythmic drug therapy at the end of the 12-month follow-up. In patients with persistent and long-standing persistent atrial fibrillation, no significant difference was observed in 12-month freedom from atrial tachyarrhythmias between an index ablative approach of stand-alone PVI and a stepwise approach of PVI plus complex fractionated atrial electrogram and linear ablation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00820625. © 2017 American Heart Association, Inc.
[TRENDS OF PERMANENT PACEMAKER IMPLANTATION IN A SINGLE CENTER OVER A 20-YEAR PERIOD].
Antonelli, Dante; Ilan, Limor Bushar; Freedberg, Nahum A; Feldman, Alexander; Turgeman, Yoav
2015-05-01
To review the changes in permanent pacemaker implantation indications, pacing modes and patients' demographics over a 20-year period. We retrospectively retrieved data on patients who underwent first implantation of the pacemaker between 1-1-1991 and 31-12-2010. One thousand and nine (1,009) patients underwent a first pacemaker implantation during that period; 535 were men (53%), their mean age was 74.6±19.5 years; the highest rate of implanted pacemaker was in patients ranging in age from 70-79 years, however there was an increasing number of patients aged over 80 years. The median survival time after initial pacemaker implantation was 8 years. Syncope was the most common symptom (62.5%) and atrioventricular block was the most common electrocardiographic indication (56.4%) leading to pacemaker implantation. There was increased utilization of dual chamber and rate responsive pacemakers over the years. There was no difference regarding mode selection between genders. Pacemaker implantation rates have increased over a 20-year period. Dual chamber replaced most of the single ventricular chamber pacemaker and rate responsive pacemakers became the norm. The data of a small volume center are similar to those reported in pacemaker surveys of high volume pacemaker implantation centers. They confirm adherence to the published guidelines for pacing.
Singh, Sheldon M; d'Avila, Andre; Kim, Young-Hoon; Aryana, Arash; Mangrum, J Michael; Michaud, Gregory F; Dukkipati, Srinivas R; Barrett, Conor D; Heist, E Kevin; Parides, Michael K; Thorpe, Kevin E; Reddy, Vivek Y
2016-05-21
Complex fractionated atrial electrograms (CFAE) are targeted during persistent atrial fibrillation (AF) ablation. However, many CFAE sites are non-specific resulting in extensive ablation. Ibutilide has been shown to reduce left atrial surface area exhibiting CFAE. We hypothesized that ibutilide administration prior to CFAE ablation would identify sites critical for persistent AF maintenance allowing for improved procedural efficacy and long-term freedom from atrial arrhythmias. Two hundred patients undergoing a first-ever persistent AF catheter ablation procedure were randomly assigned to receive either 0.25 mg of intravenous ibutilide or saline placebo upon completion of pulmonary vein isolation. Complex fractionated atrial electrogram sites were then targeted with ablation. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Similar procedural characteristics (procedure, fluoroscopy, and ablation times) were observed with both strategies despite a greater reduction in left atrial surface area with CFAE sites (8 vs. 1%, P < 0.0001) and AF termination during CFAE ablation with ibutilide compared with placebo (75 vs. 57%, P = 0.007). The primary efficacy endpoint was achieved in 56% of patients receiving ibutilide and 49% receiving placebo (P = 0.35). No significant differences in peri-procedural complications were observed in both groups. Despite a reduction in CFAE area and greater AF termination during CFAE ablation, procedural characteristics and clinical outcomes were unchanged when CFAE ablation was guided by ibutilide administration. ClinicalTrials.gov number: NCT01014741. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Clinical use of isotope cardiac pacemakers (in German)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, J.; Kreutzberg, B.
1973-01-01
Plutoninm-235 having a half-life of 86.4 yrs has proved suitable as a long-life energy source for a cardiac pacemaker. The radiation dose of this pacemaker is below the I. C. R. P.-recommended values. As the isotope pacemaker costs three times as much as a conventional pacemaker, the merits of implanting an isotope pacemaker vs. the conventional kind are discussed. A survey is given of the cases in which an isotope pacemaker has been used. (GE)
Scarano, Michele; Casale, Matteo; Mantini, Cesare; Imbalzano, Egidio; Consorti, Cristiana; Clemente, Daniela; Dattilo, Giuseppe
2017-04-09
Atrial fibrillation is the most common cardiac arrhythmia. It is responsible for up to 20% of all ischemic strokes. Rate control and anticoagulation are crucial for atrial fibrillation management and stroke prevention. We present the case of an 84-year-old Italian woman with a left atrial appendage thrombus that developed despite her use of anticoagulant therapy with warfarin for a previous pulmonary embolism. She had atrial fibrillation and heterozygosity for both factor V Leiden and methylenetetrahydrofolate reductase C677T mutation, thus creating resistance to activated protein C. Anticoagulant therapy was switched to heparin for 1 week and then to rivaroxaban. After 3 months of rivaroxaban use, the thrombus disappeared. This case raises the issue of the ineffectiveness of warfarin therapy in complex cases involving particular thrombophilic conditions and the possibility of using rivaroxaban as a safe and effective alternative.
Dynamical mechanism of atrial fibrillation: A topological approach
NASA Astrophysics Data System (ADS)
Marcotte, Christopher D.; Grigoriev, Roman O.
2017-09-01
While spiral wave breakup has been implicated in the emergence of atrial fibrillation, its role in maintaining this complex type of cardiac arrhythmia is less clear. We used the Karma model of cardiac excitation to investigate the dynamical mechanisms that sustain atrial fibrillation once it has been established. The results of our numerical study show that spatiotemporally chaotic dynamics in this regime can be described as a dynamical equilibrium between topologically distinct types of transitions that increase or decrease the number of wavelets, in general agreement with the multiple wavelets' hypothesis. Surprisingly, we found that the process of continuous excitation waves breaking up into discontinuous pieces plays no role whatsoever in maintaining spatiotemporal complexity. Instead, this complexity is maintained as a dynamical balance between wave coalescence—a unique, previously unidentified, topological process that increases the number of wavelets—and wave collapse—a different topological process that decreases their number.
[Lifetime achievements of Milan H. Djordjević. 1933-1993].
Pavlović, Sinisa U
2002-09-01
Professor Dr. Sci. Milan Djordjevitsh was an excellent cardiovascular surgeon and results of his professional and research work were well known to professional public in the country and over the world. He was born in Smederevska Palanka in 1933. He finished the University Schfool of Medicine in Belgrade in 1961 and specialized general surgery at the II Department of Surgery in Belgrade. His teacher, prof. dr. Vojislav Stojanovitsh, recognized his special interest for clinical and research work from the beginning. His doctor's thesis (1976) was "The Role of Veinous Valvula in Aortocoronographic Bypass During Increased Coronary Flow". In 1981 he formed a Bypass Centre of the Republic of Serbia which became later the Yugoslav European Reference Centre for pacemaker therapy. The same year (1981) he was rewarded "The October Award of the City of Belgrade" for science. He was the first to implant an implantable cardioverter defibrillator. This technique was carried out in Serbia only two months after the implantation of a similar system in Europe. Professor Djordjevitsh gave many lectures over the world: Detroit (1975), Huston (1975), Budapest (1978), Warsaw (1980), Stockholm (1982), Aman (1984), New-York (1988), Berlin (1987), Vienna (1998), Stockholm (1989), Moscow (1990). The professional and research work of professor Djordjevitsh in the field of electrostimulation of the heart was characterised by original ideas and permanent search for new possibilities, especially in the multidisciplinary field. Therefore, professor Djordjevitsh is considered to be the founder of modern clinical pacemaker therapy. He also practiced artistic and scientific photography. Since 1984 professor Djordjevitsh was member of the Nucleus of the European working group for heart electrostimulation and electrophysiology, and was elected in the presidency of the Nucleus; later he was its president. His interest was directed to the maturation of endocardial stimulation threshold; use of non-atrial sensors in the frequent adaptation of a permanent artificial conductor of cardiac rhythm-pacemaker to load; use of continuous electrostimulation of spinal cord in patients in terminal state of vasospastic and occlusive vascular diseases; study of the effort of electromagnetic fields on pacemaker inhibition and senzation; study of biologic-synthetic grafts. As a man of high standing, professor Djordjevitsh was expert for cardiovascular diseases and modern technology in the World Health Organization since 1988. On the basis of his great professional reputation in the country and abroad, professor Djordjevitsh was elected a corresponding member of the Serbian Academy of Science and Arts. After a few scientific meetings excellently organized by professor Djordjevitsh in the country (Dubrovnik, 1988 and in 1990 under the auspices of NASPE), professor Djordjevitsh had to organize a European congress on Pacemaker Therapy and Electrophysiology in Belgrade in 1993. Unfortunately, political events and early death of professor Djordjevitsh were the reasons why the congress was not held as planned. Professor Djordjevic died in Paris, but was buried in Belgrade in January 1993.
Pacemaker Dependency after Cardiac Surgery: A Systematic Review of Current Evidence.
Steyers, Curtis M; Khera, Rohan; Bhave, Prashant
2015-01-01
Severe postoperative conduction disturbances requiring permanent pacemaker implantation frequently occur following cardiac surgery. Little is known about the long-term pacing requirements and risk factors for pacemaker dependency in this population. We performed a systematic review of the literature addressing rates and predictors of pacemaker dependency in patients requiring permanent pacemaker implantation after cardiac surgery. Using a comprehensive search of the Medline, Web of Science and EMBASE databases, studies were selected for review based on predetermined inclusion and exclusion criteria. A total of 8 studies addressing the endpoint of pacemaker-dependency were identified, while 3 studies were found that addressed the recovery of atrioventricular (AV) conduction endpoint. There were 10 unique studies with a total of 780 patients. Mean follow-up ranged from 6-72 months. Pacemaker dependency rates ranged from 32%-91% and recovery of AV conduction ranged from 16%-42%. There was significant heterogeneity with respect to the definition of pacemaker dependency. Several patient and procedure-specific variables were found to be independently associated with pacemaker dependency, but these were not consistent between studies. Pacemaker dependency following cardiac surgery occurs with variable frequency. While individual studies have identified various perioperative risk factors for pacemaker dependency and non-resolution of AV conduction disease, results have been inconsistent. Well-conducted studies using a uniform definition of pacemaker dependency might identify patients who will benefit most from early permanent pacemaker implantation after cardiac surgery.
Genovese, David W; Estrada, Amara H; Maisenbacher, Herbert W; Heatwole, Bonnie A; Powell, Melanie A
2013-01-15
To compare procedure times and major and minor complication rates associated with single-chamber versus dual-chamber pacemaker implantation and with 1-lead, 2-lead, and 3-lead pacemaker implantation in dogs with clinical signs of bradyarrhythmia. Retrospective case series. 54 dogs that underwent pacemaker implantation because of clinical signs of bradyarrhythmia. Medical records of dogs that received pacemakers between July 2004 and December 2009 were reviewed for information regarding signalment, diagnosis, pacemaker implantation, pacemaker type, complications, and survival time. Analyses were performed to determine significant differences in anesthesia time, procedure time, and outcome for dogs on the basis of pacing mode and number of pacing leads. 28 of 54 (51.9%) dogs received single-chamber pacemakers and 26 (48.1%) received dual-chamber pacemakers. Mean ± SD procedural time was significantly longer for patients with dual-chamber pacemakers (133.5 ± 51.3 minutes) than for patients with single-chamber pacemakers (94.9 ± 37.0 minutes), and procedure time increased significantly as the number of leads increased (1 lead, 102.3 ± 51.1 minutes; 2 leads, 114.9 ± 24.8 minutes; 3 leads, 158.2 ± 8.5 minutes). Rates of major and minor complications were not significantly different between dogs that received single-chamber pacemakers and those that received dual-chamber pacemakers or among dogs grouped on the basis of the number of pacing leads placed. Although dual-chamber pacemaker implantation did result in increased procedural and anesthesia times, compared with single-chamber pacemaker implantation, this did not result in a higher complication rate.
21 CFR 870.3640 - Indirect pacemaker generator function analyzer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...
21 CFR 870.3640 - Indirect pacemaker generator function analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...
21 CFR 870.3640 - Indirect pacemaker generator function analyzer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...
21 CFR 870.3640 - Indirect pacemaker generator function analyzer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review.
Tjong, Fleur V Y; Reddy, Vivek Y
2017-04-11
A new technology, leadless pacemaker therapy, was recently introduced clinically to address lead- and pocket-related complications in conventional transvenous pacemaker therapy. These leadless devices are self-contained right ventricular single-chamber pacemakers implanted by using a femoral percutaneous approach. In this review of available clinical data on leadless pacemakers, early results with leadless devices are compared with historical results with conventional single-chamber pacing. Both presently manufactured leadless pacemakers show similar complications, which are mostly related to the implant procedure: cardiac perforation, device dislocation, and femoral vascular access site complications. In comparison with conventional transvenous single-chamber pacemakers, slightly higher short-term complication rates have been observed: 4.8% for leadless pacemakers versus 4.1% for conventional pacemakers. The complication rate of the leadless pacemakers is influenced by the implanter learning curve for this new procedure. No long-term outcome data are yet available for the leadless pacemakers. Larger leadless pacing trials, with long-term follow-up and direct randomized comparison with conventional pacing systems, will be required to define the proper clinical role of these leadless systems. Although current leadless pacemakers are limited to right ventricular pacing, future advanced, communicating, multicomponent systems are expected to expand the potential benefits of leadless therapy to a larger patient population. © 2017 American Heart Association, Inc.
Khine, Htet W; Steding-Ehrenborg, Katarina; Hastings, Jeffrey L; Kowal, Jamie; Daniels, James D; Page, Richard L; Goldberger, Jeffery J; Ng, Jason; Adams-Huet, Beverley; Bungo, Michael W; Levine, Benjamin D
2018-05-01
The prevalence of atrial fibrillation (AF) in active astronauts is ≈5%, similar to the general population but at a younger age. Risk factors for AF include left atrial enlargement, increased number of premature atrial complexes, and certain parameters on signal-averaged electrocardiography, such as P-wave duration, root mean square voltage for the terminal 20 ms of the signal-averaged P wave, and P-wave amplitude. We aimed to evaluate changes in atrial structure, supraventricular beats, and atrial electrophysiology to determine whether spaceflight could increase the risk of AF. Thirteen astronauts underwent cardiac magnetic resonance imaging to assess atrial structure and function before and after 6 months in space and high-resolution Holter monitoring for multiple 48-hour time periods before flight, during flight, and on landing day. Left atrial volume transiently increased after 6 months in space (12±18 mL; P =0.03) without changing atrial function. Right atrial size remained unchanged. No changes in supraventricular beats were noted. One astronaut had a large increase in supraventricular ectopic beats but none developed AF. Filtered P-wave duration did not change over time, but root mean square voltage for the terminal 20 ms decreased on all fight days except landing day. No changes in P-wave amplitude were seen in leads II or V 1 except landing day for lead V 1 . Six months of spaceflight may be sufficient to cause transient changes in left atrial structure and atrial electrophysiology that increase the risk of AF. However, there was no definite evidence of increased supraventricular arrhythmias and no identified episodes of AF. © 2018 American Heart Association, Inc.
Cibis, Merih; Lindahl, Tomas L; Ebbers, Tino; Karlsson, Lars O; Carlhäll, Carl-Johan
2017-01-01
Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from the entire three-dimensional atrial volume throughout the cardiac cycle. We sought to investigate left atrial 4D blood flow patterns and hemostasis during left atrial stunning and after left atrial mechanical function was restored. Methods: 4D Flow and morphological CMR data as well as blood samples were collected in fourteen patients at two time-points: 2-3 h (Time-1) and 4 weeks (Time-2) following cardioversion. The volume of blood stasis and duration of blood stasis were calculated. In addition, hemostasis markers were analyzed. Results: From Time-1 to Time-2: Heart rate decreased (61 ± 7 vs. 56 ± 8 bpm, p = 0.01); Maximum change in left atrial volume increased (8 ± 4 vs. 22 ± 15%, p = 0.009); The duration of stasis (68 ± 11 vs. 57 ± 8%, p = 0.002) and the volume of stasis (14 ± 9 vs. 9 ± 7%, p = 0.04) decreased; Thrombin-antithrombin complex (TAT) decreased (5.2 ± 3.3 vs. 3.3 ± 2.2 μg/L, p = 0.008). A significant correlation was found between TAT and the volume of stasis ( r 2 = 0.69, p < 0.001) at Time-1 and between TAT and the duration of stasis ( r 2 = 0.34, p = 0.04) at Time-2. Conclusion: In this longitudinal study, left atrial multidimensional blood flow was altered and blood stasis was elevated during left atrial stunning compared to the restored left atrial mechanical function. The coagulability of blood was also elevated during atrial stunning. The association between blood stasis and hypercoagulability proposes that assessment of left atrial 4D flow can add to the pathophysiological understanding of thrombus formation during atrial fibrillation related atrial stunning.
Centrifuge-simulated suborbital spaceflight in subjects with cardiac implanted devices.
Blue, Rebecca S; Reyes, David P; Castleberry, Tarah L; Vanderploeg, James M
2015-04-01
Future commercial spaceflight participants (SFPs) with conditions requiring personal medical devices represent a unique challenge. The behavior under stress of cardiac implanted devices (CIDs) such as pacemakers is of special concern. No known data currently exist on how such devices may react to the stresses of spaceflight. We examined the responses of two volunteer subjects with CIDs to G forces in a centrifuge to evaluate how similar potential commercial SFPs might tolerate the forces of spaceflight. Two subjects, 75- and 79-yr-old men with histories of atrial fibrillation and implanted dual-lead, rate-responsive pacemakers, underwent seven centrifuge runs over 2 d. Day 1 consisted of two +Gz runs (peak = +3.5 Gz, run 2) and two +Gx runs (peak = +6.0 Gx, run 4). Day 2 consisted of three runs approximating suborbital spaceflight profiles (combined +Gx/+Gz). Data collected included blood pressures, electrocardiograms, pulse oximetry, neurovestibular exams, and postrun questionnaires regarding motion sickness, disorientation, greyout, and other symptoms. Despite both subjects' significant medical histories, neither had abnormal physiological responses. Post-spin analysis demonstrated no lead displacement, damage, or malfunction of either CID. Potential risks to SFPs with CIDs include increased arrhythmogenesis, lead displacement, and device damage. There are no known prior studies of individuals with CIDs exposed to accelerations anticipated during the dynamic phases of suborbital spaceflight. These cases demonstrate that even individuals with significant medical histories and implanted devices can tolerate the acceleration exposures of commercial spaceflight. Further investigation will determine which personal medical devices present significant risks during suborbital flight and beyond.
21 CFR 870.3620 - Pacemaker lead adaptor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker lead adaptor. 870.3620 Section 870.3620...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3620 Pacemaker lead adaptor. (a) Identification. A pacemaker lead adaptor is a device used to adapt a pacemaker lead so that it...
21 CFR 870.3620 - Pacemaker lead adaptor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker lead adaptor. 870.3620 Section 870.3620...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3620 Pacemaker lead adaptor. (a) Identification. A pacemaker lead adaptor is a device used to adapt a pacemaker lead so that it...
21 CFR 870.3620 - Pacemaker lead adaptor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker lead adaptor. 870.3620 Section 870.3620...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3620 Pacemaker lead adaptor. (a) Identification. A pacemaker lead adaptor is a device used to adapt a pacemaker lead so that it...
21 CFR 870.3610 - Implantable pacemaker pulse generator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Implantable pacemaker pulse generator. 870.3610... pacemaker pulse generator. (a) Identification. An implantable pacemaker pulse generator is a device that has... implantable pacemaker pulse generator device that was in commercial distribution before May 28, 1976, or that...
21 CFR 870.3620 - Pacemaker lead adaptor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker lead adaptor. 870.3620 Section 870.3620...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3620 Pacemaker lead adaptor. (a) Identification. A pacemaker lead adaptor is a device used to adapt a pacemaker lead so that it...
21 CFR 870.3610 - Implantable pacemaker pulse generator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Implantable pacemaker pulse generator. 870.3610... pacemaker pulse generator. (a) Identification. An implantable pacemaker pulse generator is a device that has... implantable pacemaker pulse generator device that was in commercial distribution before May 28, 1976, or that...
Racing of the biological pacemaker.
Yu, Han-Gang
2009-01-01
Over the past decade, rapid progress in the molecular studies of cardiac ion channels and stem cells biology has led to efforts to create a biological pacemaker to supplement the widely-used electronic pacemaker. We will review the main concepts of cardiac pacemaker activities in different heart regions and the approaches to design a working biological pacemaker. We will focus on how to use the gene- and cell-based approaches to meet the requirements of a working biological pacemaker. Possible future development and precautions for creation of an effective biological pacemaker superior to the electronic counterpart are also discussed along with recent patents.
Pacemaker Dependency after Cardiac Surgery: A Systematic Review of Current Evidence
2015-01-01
Background Severe postoperative conduction disturbances requiring permanent pacemaker implantation frequently occur following cardiac surgery. Little is known about the long-term pacing requirements and risk factors for pacemaker dependency in this population. Methods We performed a systematic review of the literature addressing rates and predictors of pacemaker dependency in patients requiring permanent pacemaker implantation after cardiac surgery. Using a comprehensive search of the Medline, Web of Science and EMBASE databases, studies were selected for review based on predetermined inclusion and exclusion criteria. Results A total of 8 studies addressing the endpoint of pacemaker-dependency were identified, while 3 studies were found that addressed the recovery of atrioventricular (AV) conduction endpoint. There were 10 unique studies with a total of 780 patients. Mean follow-up ranged from 6–72 months. Pacemaker dependency rates ranged from 32%-91% and recovery of AV conduction ranged from 16%-42%. There was significant heterogeneity with respect to the definition of pacemaker dependency. Several patient and procedure-specific variables were found to be independently associated with pacemaker dependency, but these were not consistent between studies. Conclusions Pacemaker dependency following cardiac surgery occurs with variable frequency. While individual studies have identified various perioperative risk factors for pacemaker dependency and non-resolution of AV conduction disease, results have been inconsistent. Well-conducted studies using a uniform definition of pacemaker dependency might identify patients who will benefit most from early permanent pacemaker implantation after cardiac surgery. PMID:26470027
Falase, Bode; Sanusi, Michael; Johnson, Adeyemi; Akinrinlola, Fola; Ajayi, Reina; Oke, David
2013-01-01
Introduction Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker data collection. A pacemaker database has been developed in our institution and the results are analyzed in this study. Methods The study period was between January 2008 and December 2012. Patient data was extracted from a prospectively maintained database which was designed to include the fields of the European pacemaker patient identification code. Results Of the 51 pacemaker implants done, there were 29 males (56.9%) and 22 females (43.1%). Mean age was 68.2±12.7 years. Clinical indications were syncopal attacks in 25 patients (49%), dizzy spells in 15 patients (29.4%), bradycardia with no symptoms in 10 patients (17.7%) and dyspnoea in 2 patients (3.9%). The ECG diagnosis was complete heart block in 27 patients (53%), second degree heart block in 19 patients (37.2%) and sick sinus syndrome with bradycardia in 5 patients (9.8%). Pacemaker modes used were ventricular pacing in 29 patients (56.9%) and dual chamber pacing in 22 patients (43.1%). Files have been closed in 20 patients (39.2%) and 31 patients (60.8%) are still being followed up with median follow up of 26 months, median of 5 visits and 282 pacemaker checks done. Complications seen during follow up were 3 lead displacements (5.9%), 3 pacemaker infections (5.9%), 2 pacemaker pocket erosions (3.9%), and 1 pacemaker related death (2%). There were 5 non-pacemaker related deaths (9.8%). Conclusion Pacemaker data has been maintained for 5 years. We urge other implanting institutions in Nigeria to maintain similar databases and work towards establishment of a national pacemaker registry. PMID:24498465
Tscholl, Verena; Lsharaf, Abdullah Khaled-A; Lin, Tina; Bellmann, Barbara; Biewener, Sebastian; Nagel, Patrick; Suhail, Saba; Lenz, Klaus; Landmesser, Ulf; Roser, Mattias; Rillig, Andreas
2016-09-01
The efficacy of the second-generation cryoballoon (CB) in patients with paroxysmal atrial fibrillation (AF) has been demonstrated previously. Data on the efficacy of CB ablation in patients with persistent AF are sparse. The aim of this study was to evaluate the 2-year success rate of pulmonary vein isolation in patients with persistent AF using the second-generation CB. Fifty consecutive patients (mean age 64.6 ± 9.9 years; 19 women [38%]) with persistent AF were included in this analysis. The mean follow-up period was 22 ± 11 months. All patients were ablated using the second-generation 28-mm CB. Isolation of the pulmonary veins was confirmed using a spiral mapping catheter. In all patients, follow-up was obtained using 24-hour Holter monitoring or via interrogation of an implanted loop recorder or pacemaker. The mean left atrial diameter was 43.6 ± 5.6 mm, the mean CHA2DS2-VASc score was 2.8 ± 1.5, and the mean HAS-BLED score was 2.1 ± 1.2. The mean fluoroscopy time was 25.8 ± 9 minutes, and the mean procedural time was 146.4 ± 37.8 minutes. After 22 ± 11 months, the frequency of arrhythmia recurrence was 22 of 50 (44%) in the overall group (paroxysmal AF 6 of 22 [27%]; persistent AF 16 of 22 [73%]). No major complications occurred. Aneurysma spurium not requiring surgical intervention occurred in 1 (2%) patient. No phrenic nerve palsy was observed. Two years' results after pulmonary vein isolation using the second-generation CB in patients with persistent AF are promising. The clinical success rate appears to be similar to the reported success rates of radiofrequency ablation for the treatment of persistent AF. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Skarda, R T; Muir, W W; Bednarski, R M; Hubbell, J A; Mason, D E
1995-01-01
The purpose of this study was to review the incidence of cardiac arrhythmias in 137 anesthetized dogs and 13 anesthetized cats with congenital or acquired heart disease that were referred for correction of following procedures: patent ductus arteriosus (PDA-ligation, 28%), cardiac catheterization with angiogram and angioplasty (22%), pacemaker implantation (18%), exploratory lateral thoracotomy (8.7%), correction of right aortic arch (ring anomaly, 3.3%), correction of subvalvular aortic stenosis (2.7%), correction of PDA with coil in patients with mitral regurgitation and congestive heart failure (2%), pericardectomy and removal of heart base tumor (2%), and palliative surgery for ventricular septal defect (VSD, 0.7%). The anesthetic plan considered the risks of anesthesia based upon the pathophysiology of cardiac lesions and the anesthetic drug effects on the cardiovascular system. Recommendations are made for dogs with decreased cardiac contractility, cardiac disease with volume overload, cardiac disease with pressure overload, and pericardial tamponade. The percentages of animals and their associated cardiac arrhythmias after premedication and during and after anesthesia were: sinus bradycardia (15.3%), sinus tachycardia (3.3%), atrial flutter (0.7%), atrial fibrillation (0.7%), premature ventricular contraction (14%), and ventricular tachycardia (1.3%). Prompt therapy was given to a percentage of animals in order to control arrhythmia and support cardiovascular system, by using atropine or glycopyrrolate (14%), lidocaine (17.3%), and dopamine (14.7%).(ABSTRACT TRUNCATED AT 250 WORDS)
[Sport for pacemaker patients].
Israel, C W
2012-06-01
Sport activity is an important issue in many patients with a pacemaker either because they performed sport activities before pacemaker implantation to reduce the cardiovascular risk or to improve the course of an underlying cardiovascular disease (e.g. coronary artery disease, heart failure) by sports. Compared to patients with an implantable cardioverter defibrillator (ICD) the risks from underlying cardiovascular disease (e.g. ischemia, heart failure), arrhythmia, lead dysfunction or inappropriate therapy are less important or absent. Sport is contraindicated in dyspnea at rest, acute heart failure, new complex arrhythmia, acute myocarditis and acute myocardial infarction, valvular disease with indications for intervention and surgery and comorbidities which prevent physical activity. Patients with underlying cardiovascular disease (including hypertension) should preferably perform types and levels of physical activity that are aerobic (with dynamic exercise) such as running, swimming, cycling instead of sport with high anaerobic demands and high muscular workload. In heart failure, studies demonstrated advantages of isometric sport that increases the amount of muscle, thereby preventing cardiac cachexia. Sport with a risk of blows to the chest or physical contact (e.g. boxing, rugby, martial arts) should be avoided. Implantation, programming and follow-up should respect specific precautions to allow optimal physical activity with a pacemaker including implantation of bipolar leads on the side contralateral to the dominant hand, individual programming of the upper sensor and tracking rate and regular exercise testing.
Electrical interference in non-competitive pacemakers
Sowton, E.; Gray, K.; Preston, T.
1970-01-01
Patients with 41 implanted non-competitive pacemakers were investigated. A variety of domestic electrical equipment, a motor-car, and a physiotherapy diathermy apparatus were each operated in turn at various ranges from the patient. Interference effects on pacemaker function were assessed on the electrocardiograph. Medtronic demand 5841 pacemakers were stopped by diathermy while Cordis Ectocor pacemakers developed a fast discharge rate. Cordis triggered pacemakers (both Atricor and Ectocor) were sensitive to interference from many items of domestic equipment and the motor car. The Elema EM153 ran at an increased rate when an electric razor was running close to the pacemaker. The Devices demand 2980 and the Medtronic demand 5841 were not affected by the domestic equipment tested. The significance of interference effects is discussed in relation to pacemaker design. Images PMID:5470044
Tobón, Catalina; Ruiz-Villa, Carlos A.; Heidenreich, Elvio; Romero, Lucia; Hornero, Fernando; Saiz, Javier
2013-01-01
The most common sustained cardiac arrhythmias in humans are atrial tachyarrhythmias, mainly atrial fibrillation. Areas of complex fractionated atrial electrograms and high dominant frequency have been proposed as critical regions for maintaining atrial fibrillation; however, there is a paucity of data on the relationship between the characteristics of electrograms and the propagation pattern underlying them. In this study, a realistic 3D computer model of the human atria has been developed to investigate this relationship. The model includes a realistic geometry with fiber orientation, anisotropic conductivity and electrophysiological heterogeneity. We simulated different tachyarrhythmic episodes applying both transient and continuous ectopic activity. Electrograms and their dominant frequency and organization index values were calculated over the entire atrial surface. Our simulations show electrograms with simple potentials, with little or no cycle length variations, narrow frequency peaks and high organization index values during stable and regular activity as the observed in atrial flutter, atrial tachycardia (except in areas of conduction block) and in areas closer to ectopic activity during focal atrial fibrillation. By contrast, cycle length variations and polymorphic electrograms with single, double and fragmented potentials were observed in areas of irregular and unstable activity during atrial fibrillation episodes. Our results also show: 1) electrograms with potentials without negative deflection related to spiral or curved wavefronts that pass over the recording point and move away, 2) potentials with a much greater proportion of positive deflection than negative in areas of wave collisions, 3) double potentials related with wave fragmentations or blocking lines and 4) fragmented electrograms associated with pivot points. Our model is the first human atrial model with realistic fiber orientation used to investigate the relationship between different atrial arrhythmic propagation patterns and the electrograms observed at more than 43000 points on the atrial surface. PMID:23408928
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bridges, J.E.; Frazier, M.J.
1979-09-01
The effects of 60-Hz electric and magnetic fields of exta-high voltage (EHV) transmission lines on the performance of implanted cardiac pacemakers were studied by: (1) in vitro bench tests of a total of thirteen cardiac pacemakers; (2) in vivo tests of six implanted cardiac pacemakers in baboons; and (3) non-hazardous skin measurement tests on four humans. Analytical methods were developed to predict the thresholds of body current and electric fields capable of affecting normal pacemaker operation in humans. The field strengths calculated to alter implanted pacemaker performance were compared with the range of maximum electric and magnetic field strengths amore » human would normally encounter under transmission lines of various voltages. Results indicate that the electric field or body current necessary to alter the normal operation of pacemakers is highly dependent on the type of pacemaker and the location of the implanted electrodes. However, cardiologists have not so far detected harmful effects of pacemaker reversion to the asynchronous mode in current types of pacemakers and with present methods of implantation. Such interferences can be eliminated by using advanced pacemakers less sensitive to 60-Hz voltages or by using implantation lead arrangements less sensitive to body current.« less
Heart failure and atrial fibrillation: current concepts and controversies.
Van den Berg, M. P.; Tuinenburg, A. E.; Crijns, H. J.; Van Gelder, I. C.; Gosselink, A. T.; Lie, K. I.
1997-01-01
Heart failure and atrial fibrillation are very common, particularly in the elderly. Owing to common risk factors both disorders are often present in the same patient. In addition, there is increasing evidence of a complex, reciprocal relation between heart failure and atrial fibrillation. Thus heart failure may cause atrial fibrillation, with electromechanical feedback and neurohumoral activation playing an important mediating role. In addition, atrial fibrillation may promote heart failure; in particular, when there is an uncontrolled ventricular rate, tachycardiomyopathy may develop and thereby heart failure. Eventually, a vicious circle between heart failure and atrial fibrillation may form, in which neurohumoral activation and subtle derangement of rate control are involved. Treatment should aim at unloading of the heart, adequate control of ventricular rate, and correction of neurohumoral activation. Angiotensin converting enzyme inhibitors may help to achieve these goals. Treatment should also include an attempt to restore sinus rhythm through electrical cardioversion, though appropriate timing of cardioversion is difficult. His bundle ablation may be used to achieve adequate rate control in drug refractory cases. PMID:9155607
Pacemaker Use Following Heart Transplantation
Mallidi, Hari R.; Bates, Michael
2017-01-01
Background: The incidence of permanent pacemaker implantation after orthotopic heart transplantation has been reported to be 2%-24%. Transplanted hearts usually exhibit sinus rhythm in the operating room following reperfusion, and most patients do not exhibit significant arrhythmias during the postoperative period. However, among the patients who do exhibit abnormalities, pacemakers may be implanted for early sinus node dysfunction but are rarely used after 6 months. Permanent pacing is often required for atrioventricular block. A different cohort of transplant patients presents later with bradycardia requiring pacemaker implantation, reported to occur in approximately 1.5% of patients. The objectives of this study were to investigate the indications for pacemaker implantation, compare the need for pacemakers following bicaval vs biatrial anastomosis, and examine the long-term outcomes of heart transplant patients who received pacemakers. Methods: For this retrospective, case-cohort, single-institution study, patients were identified from clinical research and administrative transplant databases. Information was supplemented with review of the medical records. Standard statistical techniques were used, with chi-square testing for categorical variables and the 2-tailed t test for continuous variables. Survival was compared with the use of log-rank methods. Results: Between January 1968 and February 2008, 1,450 heart transplants were performed at Stanford University. Eighty-four patients (5.8%) were identified as having had a pacemaker implanted. Of these patients, 65.5% (55) had the device implanted within 30 days of transplantation, and 34.5% (29) had late implantation. The mean survival of patients who had an early pacemaker implant was 6.4 years compared to 7.7 years for those with a late pacemaker implant (P<0.05). Sinus node dysfunction and heart block were the most common indications for pacemaker implantation. Starting in 1997, a bicaval technique was used for implantation. The incidence of pacemaker implantation by technique was 2.0% for bicaval and 9.1% for biatrial (P=0.001). Significantly more rejection episodes occurred in the pacemaker group (2.67 ± 2.18) compared with the no-pacemaker group (2.01 ± 2.05) (P<0.05). Conclusion: Our results show a decreased pacemaker need after bicaval anastomosis and that more patients who needed a pacemaker after transplantation had a pretransplant diagnosis of ischemic cardiomyopathy. In our cohort, the need for a permanent pacemaker was also associated with older donor grafts and an increase in the number of treated rejection episodes. PMID:28331443
[Wide QRS tachycardia preceded by pacemaker spikes].
Romero, M; Aranda, A; Gómez, F J; Jurado, A
2014-04-01
The differential diagnosis and therapeutic management of wide QRS tachycardia preceded by pacemaker spike is presented. The pacemaker-mediated tachycardia, tachycardia fibrillo-flutter in patients with pacemakers, and runaway pacemakers, have a similar surface electrocardiogram, but respond to different therapeutic measures. The tachycardia response to the application of a magnet over the pacemaker could help in the differential diagnosis, and in some cases will be therapeutic, as in the case of a tachycardia-mediated pacemaker. Although these conditions are diagnosed and treated in hospitals with catheterization laboratories using the application programmer over the pacemaker, patients presenting in primary care clinic and emergency forced us to make a diagnosis and treat the haemodynamically unstable patient prior to referral. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewin, A.A.; Serago, C.F.; Schwade, J.G.
1984-10-01
New multi-programmable pacemakers frequently employ complementary metal oxide semiconductors (CMOS). This circuitry appears more sensitive to the effects of ionizing radiation when compared to the semiconductor circuits used in older pacemakers. A case of radiation induced runaway pacemaker in a CMOS device is described. Because of this and other recent reports of radiation therapy-induced CMOS type pacemaker failure, these pacemakers should not be irradiated. If necessary, the pacemaker can be shielded or moved to a site which can be shielded before institution of radiation therapy. This is done to prevent damage to the CMOS circuit and the life threatening arrythmiasmore » which may result from such damage.« less
Sacral neuromodulation and cardiac pacemakers.
Roth, Ted M
2010-08-01
Potential for cross-talk between cardiac pacemakers and sacral neuromodulation remains speculative. We present a case series of patients with cardiac pacemakers who underwent staged Interstim (Medtronic, Minneapolis, MN) implantation and patients who had pulse generator implantation who later required cardiac pacemakers. No cross-talk was demonstrated in either group. Sacral neuromodulation appears to be safe in the setting of cardiac pacemakers without cardioversion/defibrillation technology.
On the Evolution of the Cardiac Pacemaker
Burkhard, Silja; van Eif, Vincent; Garric, Laurence; Christoffels, Vincent M.; Bakkers, Jeroen
2017-01-01
The rhythmic contraction of the heart is initiated and controlled by an intrinsic pacemaker system. Cardiac contractions commence at very early embryonic stages and coordination remains crucial for survival. The underlying molecular mechanisms of pacemaker cell development and function are still not fully understood. Heart form and function show high evolutionary conservation. Even in simple contractile cardiac tubes in primitive invertebrates, cardiac function is controlled by intrinsic, autonomous pacemaker cells. Understanding the evolutionary origin and development of cardiac pacemaker cells will help us outline the important pathways and factors involved. Key patterning factors, such as the homeodomain transcription factors Nkx2.5 and Shox2, and the LIM-homeodomain transcription factor Islet-1, components of the T-box (Tbx), and bone morphogenic protein (Bmp) families are well conserved. Here we compare the dominant pacemaking systems in various organisms with respect to the underlying molecular regulation. Comparative analysis of the pathways involved in patterning the pacemaker domain in an evolutionary context might help us outline a common fundamental pacemaker cell gene programme. Special focus is given to pacemaker development in zebrafish, an extensively used model for vertebrate development. Finally, we conclude with a summary of highly conserved key factors in pacemaker cell development and function. PMID:29367536
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sung, Wonmo; Kim, Siyong; Kim, Jung-in
2012-10-15
Purpose: To investigate dose perturbations for pacemaker-implanted patients in partial breast irradiation using high dose rate (HDR) balloon brachytherapy. Methods: Monte Carlo (MC) simulations were performed to calculate dose distributions involving a pacemaker in Ir-192 HDR balloon brachytherapy. Dose perturbations by varying balloon-to-pacemaker distances (BPD = 50 or 100 mm) and concentrations of iodine contrast medium (2.5%, 5.0%, 7.5%, and 10.0% by volume) in the balloon were investigated for separate parts of the pacemaker (i.e., battery and substrate). Relative measurements using an ion-chamber were also performed to confirm MC results. Results: The MC and measured results in homogeneous media withoutmore » a pacemaker agreed with published data within 2% from the balloon surface to 100 mm BPD. Further their dose distributions with a pacemaker were in a comparable agreement. The MC results showed that doses over the battery were increased by a factor of 3, compared to doses without a pacemaker. However, there was no significant dose perturbation in the middle of substrate but up to 70% dose increase in the substrate interface with the titanium capsule. The attenuation by iodine contrast medium lessened doses delivered to the pacemaker by up to 9%. Conclusions: Due to inhomogeneity of pacemaker and contrast medium as well as low-energy photons in Ir-192 HDR balloon brachytherapy, the actual dose received in a pacemaker is different from the homogeneous medium-based dose and the external beam-based dose. Therefore, the dose perturbations should be considered for pacemaker-implanted patients when evaluating a safe clinical distance between the balloon and pacemaker.« less
Takahashi, Masao; Badenco, Nicolas; Monteau, Jacques; Gandjbakhch, Estelle; Extramiana, Fabrice; Urena, Marina; Karam, Nicole; Marijon, Eloi; Algalarrondo, Vincent; Teiger, Emmanuel; Lellouche, Nicolas
2018-03-14
This study aimed to assess the impact of pacemaker mode programming on clinical outcomes in patients with high-degree atrioventricular conduction disturbance (AVCD) after transcatheter aortic valve implantation (TAVI). Although high-degree AVCD after TAVI can receive pacemaker, recovery of the AVCD is often observed. Specific pacemaker algorithms (AAI-DDD mode switch) are available which favor spontaneous atrioventricular conduction. Of 1,621 consecutive multi-center TAVI patients, 269 (16.4%) received pacemaker. We retrospectively included 91 patients with persistent high-degree AVCD at hospital discharge. Pacemaker dependency was defined as absence, inadequate intrinsic ventricular rhythm, or ventricular pacing time > 95% on pacemaker interrogation during follow-up. Comparison of heart failure hospitalization and death between conventional DDD (cDDD) and other modes was examined (AAI-DDD and VVI). During a mean follow-up duration of 13 months, the pacemaker dependency rate was 52.8%. Patients with cDDD mode (N = 36: 40.0%) had significantly more pacemaker dependency. Multivariate analysis showed that cDDD mode was independently associated with pacemaker dependency (odds ratio = 3.63, P = 0.03). Moreover, cDDD patients had a significant higher incidence of heart failure hospitalization (Hospitalization: cDDD vs. others = 45.4% vs. 18.2%, P = 0.03) and had a higher incidence of mortality (Death: cDDD vs. the others = 27.0% vs. 4.4%, P = 0.06). Up to half of patients implanted for high-degree AVCD after TAVI had conduction recovery. Patients with cDDD programming at hospital discharge had more pacemaker dependency and a worse cardiac prognosis. Thus, pacemaker mode should be systematically set to promote spontaneous atrioventricular conduction in patients with pacemaker implantation after TAVI. © 2018 Wiley Periodicals, Inc.
Pacemakers and implantable cardioverter defibrillators--general and anesthetic considerations.
Rapsang, Amy G; Bhattacharyya, Prithwis
2014-01-01
A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia), special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Pacemaker recycling: A notion whose time has come.
Runge, Mason W; Baman, Timir S; Davis, Sheldon; Weatherwax, Kevin; Goldman, Ed; Eagle, Kim A; Crawford, Thomas C
2017-04-26
The purpose of this paper is to summarize the need, feasibility, safety, legality, and ethical perspectives of pacemaker reutilization in low- and middle-income countries (LMICs). It will also describe, in-depth, Project My Heart Your Heart (PMHYH) as a model for pacemaker reuse in LMICs. The primary source of the discussion points in this paper is a collection of 14 publications produced by the research team at the University of Michigan and its collaborative partners. The need for pacemaker reutilization in LMICs is evident. Numerous studies show that the concept of pacemaker reutilization in LMICs is feasible. Infection and device malfunction are the main concerns in regard to pacemaker reutilization, yet many studies have shown that pacemaker reuse is not associated with increased infection risk or higher mortality compared with new device implantation. Under the right circumstances, the ethical and legal bases for pacemaker reutilization are supported. PMHYH is a proof of concept pacemaker donation initiative that has allowed funeral home and crematory directors to send explanted devices to an academic center for evaluation and re-sterilization before donation to underserved patients in LMICs. The time is now to pursue large-scale studies and trials of pacemaker reuse for the betterment of society. PMHYH is leading the way in the effort and is poised to conduct a prospective randomized, non-inferiority, multicenter study to confirm the clinical efficacy and safety of pacemaker reuse, for clinical and legal support.
Atrial Tachycardias Following Atrial Fibrillation Ablation
Sághy, László; Tutuianu, Cristina; Szilágyi, Judith
2015-01-01
One of the most important proarrhythmic complications after left atrial (LA) ablation is regular atrial tachycardia (AT) or flutter. Those tachycardias that occur after atrial fibrillation (AF) ablation can cause even more severe symptoms than those from the original arrhythmia prior to the index ablation procedure since they are often incessant and associated with rapid ventricular response. Depending on the method and extent of LA ablation and on the electrophysiological properties of underlying LA substrate, the reported incidence of late ATs is variable. To establish the exact mechanism of these tachycardias can be difficult and controversial but correlates with the ablation technique and in the vast majority of cases the mechanism is reentry related to gaps in prior ablation lines. When tachycardias occur, conservative therapy usually is not effective, radiofrequency ablation procedure is mostly successful, but can be challenging, and requires a complex approach. PMID:25308808
Mayyas, Fadia; Alzoubi, Karem H.; Van Wagoner, David R.
2014-01-01
Atrial fibrillation (AF), the most common cardiac arrhythmia, is an electrocardiographic description of a condition with multiple and complex underlying mechanisms. Oxidative stress is an important driver of structural remodeling that creates a substrate for AF. Oxidant radicals may promote increase of atrial oxidative damage, electrical and structural remodeling, and atrial inflammation. AF and other cardiovascular morbidities activate angiotensin (Ang-II)-dependent and independent cascades. A key component of the renin–angiotensin-aldosterone system (RAAS) is the mineralocorticoid aldosterone. Recent studies provide evidence of myocardial aldosterone synthesis. Aldosterone promotes cardiac oxidative stress, inflammation and structural/electrical remodeling via multiple mechanisms. In HF patients, aldosterone production is enhanced. In patients and in experimental HF and AF models, aldosterone receptor antagonists have favorable influences on cardiac remodeling and oxidative stress. Therapeutic approaches that seek to reduce AF burden by modulating the aldosterone system are likely beneficial but underutilized. PMID:23993726
Balouch, Muhammad A.; Kolek, Matthew J.; Darbar, Dawood
2014-01-01
Atrial fibrillation (AF) is a common disorder with a complex and incompletely understood pathophysiology. Genetic approaches to understanding the pathophysiology of AF have led to the identification of several biological pathways important in the pathogenesis of the arrhythmia. These include pathways important for cardiac development, generation and propagation of atrial electrical impulses, and atrial remodeling and fibrosis. While common and rare genetic variants in these pathways are associated with increased susceptibility to AF, they differ substantially among patients with lone versus typical AF. Furthermore, how these pathways converge to a final common clinical phenotype of AF is unclear and might also vary among different patient populations. Here, we review the contemporary knowledge of AF pathogenesis and discuss how derangement in cardiac development, ion channel dysfunction, and promotion of atrial fibrosis may contribute to this common and important clinical disorder. PMID:25054116
Pacemaker lead fracture associated with weightlifting: a report of two cases.
Deering, J A; Pederson, D N
1993-12-01
Two cases of pacemaker lead fracture associated with weight-lifting are presented. This is a rare association which has only recently been described in the literature. In both cases, the pacemaker lead was fractured between the clavicle and the first rib, suggesting crush injury. The chest X-ray, pacemaker telemetry with measurement of lead impedance, and pacemaker reprogramming were all helpful in management.
Wireless power transfer for a pacemaker application.
Vulfin, Vladimir; Sayfan-Altman, Shai; Ianconescu, Reuven
2017-05-01
An artificial pacemaker is a small medical device that uses electrical impulses, delivered by electrodes contracting the heart muscles, to regulate the beating of the heart. The pacemaker is implanted under the skin, and uses for many years regular non-rechargeable batteries. However, the demand for rechargeable batteries in pacemakers increased, and the aim of this work is to design an efficient charging system for pacemakers.
Connectivity of Pacemaker Neurons in the Neonatal Rat Superficial Dorsal Horn
Ford, Neil C.; Arbabi, Shahriar; Baccei, Mark L.
2014-01-01
Pacemaker neurons with an intrinsic ability to generate rhythmic burst-firing have been characterized in lamina I of the neonatal spinal cord, where they are innervated by high-threshold sensory afferents. However, little is known about the output of these pacemakers, as the neuronal populations which are targeted by pacemaker axons have yet to be identified. The present study combines patch clamp recordings in the intact neonatal rat spinal cord with tract-tracing to demonstrate that lamina I pacemaker neurons contact multiple spinal motor pathways during early life. Retrograde labeling of premotor interneurons with the trans-synaptic virus PRV-152 revealed the presence of burst-firing in PRV-infected lamina I neurons, thereby confirming that pacemakers are synaptically coupled to motor networks in the spinal ventral horn. Notably, two classes of pacemakers could be distinguished in lamina I based on cell size and the pattern of their axonal projections. While small pacemaker neurons possessed ramified axons which contacted ipsilateral motor circuits, large pacemaker neurons had unbranched axons which crossed the midline and ascended rostrally in the contralateral white matter. Recordings from identified spino-parabrachial and spino-PAG neurons indicated the presence of pacemaker activity within neonatal lamina I projection neurons. Overall, these results show that lamina I pacemakers are positioned to regulate both the level of activity in developing motor circuits as well as the ascending flow of nociceptive information to the brain, thus highlighting a potential role for pacemaker activity in the maturation of pain and sensorimotor networks in the CNS. PMID:25380417
Chen, Tien-En; Kwon, Susan H; Enriquez-Sarano, Maurice; Wong, Benjamin F; Mankad, Sunil V
2013-10-01
Three-dimensional (3D) color Doppler echocardiography (CDE) provides directly measured vena contracta area (VCA). However, a large comprehensive 3D color Doppler echocardiographic study with sufficiently severe tricuspid regurgitation (TR) to verify its value in determining TR severity in comparison with conventional quantitative and semiquantitative two-dimensional (2D) parameters has not been previously conducted. The aim of this study was to examine the utility and feasibility of directly measured VCA by 3D transthoracic CDE, its correlation with 2D echocardiographic measurements of TR, and its ability to determine severe TR. Ninety-two patients with mild or greater TR prospectively underwent 2D and 3D transthoracic echocardiography. Two-dimensional evaluation of TR severity included the ratio of jet area to right atrial area, vena contracta width, and quantification of effective regurgitant orifice area using the flow convergence method. Full-volume breath-hold 3D color data sets of TR were obtained using a real-time 3D echocardiography system. VCA was directly measured by 3D-guided direct planimetry of the color jet. Subgroup analysis included the presence of a pacemaker, eccentricity of the TR jet, ellipticity of the orifice shape, underlying TR mechanism, and baseline rhythm. Three-dimensional VCA correlated well with effective regurgitant orifice area (r = 0.62, P < .0001), moderately with vena contracta width (r = 0.42, P < .0001), and weakly with jet area/right atrial area ratio. Subgroup analysis comparing 3D VCA with 2D effective regurgitant orifice area demonstrated excellent correlation for organic TR (r = 0.86, P < .0001), regular rhythm (r = 0.78, P < .0001), and circular orifice (r = 0.72, P < .0001) but poor correlation in atrial fibrillation rhythm (r = 0.23, P = .0033). Receiver operating characteristic curve analysis for 3D VCA demonstrated good accuracy for severe TR determination. Three-dimensional VCA measurement is feasible and obtainable in the majority of patients with mild or greater TR. Three-dimensional VCA measurement is also feasible in patients with atrial fibrillation but performed poorly even with <20% cycle length variation. Three-dimensional VCA has good cutoff accuracy in determining severe TR. This simple, straightforward 3D color Doppler measurement shows promise as an alternative for the quantification of TR. Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Bitter, Thomas; Gutleben, Klaus-Jürgen; Horstkotte, Dieter; Oldenburg, Olaf
2014-01-01
Sleep-disordered breathing (SDB) is of growing interest in cardiology because SDB is a highly prevalent comorbidity in patients with a variety of cardiovascular diseases. The prevalence of SDB is particularly high in patients with cardiac dysrhythmias and/or heart failure. In this setting, many patients now have implantable cardiac devices, such as pacemakers, implantable cardioverter-defibrillators or implanted cardiac resynchronisation therapy devices (CRT). Treatment of SDB using implantable cardiac devices has been studied previously, with atrial pacing and CRT being shown not to bring about satisfactory results in SDB care. The latest generations of these devices have the capacity to determine transthoracic impedance, to detect and quantify breathing efforts and to identify SDB. The capability of implantable cardiac devices to detect SDB is of potential importance for patients with cardiovascular disease, allowing screening for SDB, monitoring of the course of SDB in relation to cardiac status, and documenting of the effects of treatment. PMID:26835077
Glavis-Bloom, Justin; Vasher, Scott; Marmor, Meghan; Fine, Antonella B; Chan, Philip A; Tashima, Karen T; Lonks, John R; Kojic, Erna M
2015-11-01
Use of cardiovascular implantable electronic devices (CIED), including permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD), has increased dramatically over the past two decades. Most CIED infections are caused by staphylococci. Fungal causes are rare and their prognosis is poor. To our knowledge, there has not been a previously reported case of multifocal Candida endocarditis involving both a native left-sided heart valve and a CIED lead. Here, we report the case of a 70-year-old patient who presented with nausea, vomiting, and generalised fatigue, and was found to have Candida glabrata endocarditis involving both a native aortic valve and right atrial ICD lead. We review the literature and summarise four additional cases of CIED-associated Candida endocarditis published from 2009 to 2014, updating a previously published review of cases prior to 2009. We additionally review treatment guidelines and discuss management of CIED-associated Candida endocarditis. © 2015 Blackwell Verlag GmbH.
Fujiwara, Shohei; Komamura, Kazuo; Nakabo, Ayumi; Masaki, Mitsuru; Fukui, Miho; Sugahara, Masataka; Itohara, Kanako; Soyama, Yuko; Goda, Akiko; Hirotani, Shinichi; Mano, Toshiaki; Masuyama, Tohru
2016-02-01
Left ventricular (LV) dyssynchrony is a causal factor in LV dysfunction and thought to be associated with LV twisting motion. We tested whether three-dimensional speckle tracking (3DT) can be used to evaluate the relationship between LV twisting motion and dyssynchrony. We examined 25 patients with sick sinus syndrome who had received dual chamber pacemakers. The acute effects of ventricular pacing on LV wall motion after the switch from atrial to ventricular pacing were assessed. LV twisting motion and dyssynchrony during each pacing mode were measured using 3DT. LV dyssynchrony was calculated from the time to the minimum peak systolic area strain of 16 LV imaging segments. Ventricular pacing increased LV dyssynchrony and decreased twist and torsion. A significant correlation was observed between changes in LV dyssynchrony and changes in torsion (r = -0.65, p < 0.01). Evaluation of LV twisting motion can potentially be used for diagnosing LV dyssynchrony.
Hirata, Yasutaka; Hirahara, Norimichi; Murakami, Arata; Motomura, Noboru; Miyata, Hiroaki; Takamoto, Shinichi
2018-01-01
We analyzed the mortality and morbidity of congenital heart surgery in Japan using the Japan Cardiovascular Surgery Database (JCVSD). Data regarding congenital heart surgery performed between January 2013 and December 2014 were obtained from JCVSD. The 20 most frequent procedures were selected and the mortality rates and major morbidities were analyzed. The mortality rates of atrial septal defect repair and ventricular septal defect repair were less than 1%, and the mortality rates of tetralogy of Fallot repair, complete atrioventricular septal defect repair, bidirectional Glenn, and total cavopulmonary connection were less than 2%. The mortality rates of the Norwood procedure and total anomalous pulmonary venous connection repair were more than 10%. The rates of unplanned reoperation, pacemaker implantation, chylothorax, deep sternal infection, phrenic nerve injury, and neurological deficit were shown for each procedure. Using JCVSD, the national data for congenital heart surgery, including postoperative complications, were analyzed. Further improvements of the database and feedback for clinical practice are required.
Fox, Henrik; Bitter, Thomas; Gutleben, Klaus-Jürgen; Horstkotte, Dieter; Oldenburg, Olaf
2014-08-01
Sleep-disordered breathing (SDB) is of growing interest in cardiology because SDB is a highly prevalent comorbidity in patients with a variety of cardiovascular diseases. The prevalence of SDB is particularly high in patients with cardiac dysrhythmias and/or heart failure. In this setting, many patients now have implantable cardiac devices, such as pacemakers, implantable cardioverter-defibrillators or implanted cardiac resynchronisation therapy devices (CRT). Treatment of SDB using implantable cardiac devices has been studied previously, with atrial pacing and CRT being shown not to bring about satisfactory results in SDB care. The latest generations of these devices have the capacity to determine transthoracic impedance, to detect and quantify breathing efforts and to identify SDB. The capability of implantable cardiac devices to detect SDB is of potential importance for patients with cardiovascular disease, allowing screening for SDB, monitoring of the course of SDB in relation to cardiac status, and documenting of the effects of treatment.
Trayanova, Natalia A
2014-01-01
Atrial fibrillation (AF) is the most common sustained arrhythmia in humans. The mechanisms that govern AF initiation and persistence are highly complex, of dynamic nature, and involve interactions across multiple temporal and spatial scales in the atria. This articles aims to review the mathematical modeling and computer simulation approaches to understanding AF mechanisms and aiding in its management. Various atrial modeling approaches are presented, with descriptions of the methodological basis and advancements in both lower-dimensional and realistic geometry models. A review of the most significant mechanistic insights made by atrial simulations is provided. The article showcases the contributions that atrial modeling and simulation have made not only to our understanding of the pathophysiology of atrial arrhythmias, but also to the development of AF management approaches. A summary of the future developments envisioned for the field of atrial simulation and modeling is also presented. The review contends that computational models of the atria assembled with data from clinical imaging modalities that incorporate electrophysiological and structural remodeling could become a first line of screening for new AF therapies and approaches, new diagnostic developments, and new methods for arrhythmia prevention. PMID:24763468
Annamaria, Martino; Andrea, Scapigliati; Michela, Casella; Tommaso, Sanna; Gemma, Pelargonio; Antonio, Dello Russo; Roberto, Zamparelli; Stefano, De Paulis; Fulvio, Bellocci; Rocco, Schiavello
2008-08-01
External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected.
Ciavarella, A; Nimmo, J; Hambrook, L
2016-04-01
A 13-year-old neutered male Border Collie was presented with acute onset syncope, weakness and anorexia 10 months after transvenous pacemaker implantation. The patient was laterally recumbent, bradycardic (36 beats/min) and febrile (40.7°C) on presentation. An electrocardiogram (ECG) revealed recurrence of third-degree atrioventricular block with a ventricular escape rhythm. Fluoroscopy identified migration of the pacemaker tip through the apex of the right ventricle. Echocardiography failed to reveal any evidence of pericardial effusion or cardiac tamponade. Full postmortem was performed after euthanasia. The pacemaker lead had perforated the apex of the right ventricle and lodged in the right pleural space. Culture of blood (taken antemortem), pericardial sac, right ventricular wall (surrounding pacemaker lead), pacemaker lead tip and pericardial fluid revealed a pure growth of Moraxella phenylpyruvica. Bacteraemia associated with M. phenylpyruvica has never been reported in the dog, but sporadic cases are reported in humans. Infection could have resulted from either pre-existing myocarditis or opportunistic infection and bacteraemia post pacemaker implantation. Evaluation of the pacemaker function at regular intervals would allow early detection of poor pacemaker-to-myocardium contact, which would prompt further investigation of pacemaker lead abnormalities such as perforation. © 2016 Australian Veterinary Association.
Guo, Gongliang; Yang, Lili; Wu, Jinyi; Sun, Liqun
2017-01-01
Abstract Background: Dextrocardia, or right-lying heart, is an uncommon congenital heart disease in which the apex of the heart is located on the right side of chest. Persistent left superior vena cava (PLSVA) is a rare venous anomaly that is often associated with the abnormalities of cardiac transduction system. A case with combination of dextrocardia, persistent left superior vena cava, and sick sinus syndrome has not been reported. Methods: We used different techniques including cardiac color Doppler echocardiography, 24-hour Holter monitoring, and abdominal ultrasound to make a diagnosis and treated the patient by implanting a VVI pacemaker. Results: A 50-year-old woman was admitted with a syncope. Angiography of the right atrium and superior vena cava, echocardiography, electrocardiography, and abdominal ultrasound revealed the presence of the combination of mirror image dextrocardia, PLSVA, and sick sinus syndrome. The complex structural anomalies presented great technical challenges for interventional treatments. After thorough examination and understanding of the structural anatomy and anomalies of the superior and inferior vena cava and cardiac chambers, we successfully treated this patient by implanting a VVI pacemaker. Conclusion: Physicians must be aware of the complexity of the morphological and anatomical structures of dextrocardia accompanying PLSVC. Given that the diagnosis of situs inversus was performed at a relatively advanced age, it is therefore important to make such a correct diagnosis followed by appropriate therapeutic intervention. PMID:28151908
Pacemaker recycling: A notion whose time has come
Runge, Mason W; Baman, Timir S; Davis, Sheldon; Weatherwax, Kevin; Goldman, Ed; Eagle, Kim A; Crawford, Thomas C
2017-01-01
The purpose of this paper is to summarize the need, feasibility, safety, legality, and ethical perspectives of pacemaker reutilization in low- and middle-income countries (LMICs). It will also describe, in-depth, Project My Heart Your Heart (PMHYH) as a model for pacemaker reuse in LMICs. The primary source of the discussion points in this paper is a collection of 14 publications produced by the research team at the University of Michigan and its collaborative partners. The need for pacemaker reutilization in LMICs is evident. Numerous studies show that the concept of pacemaker reutilization in LMICs is feasible. Infection and device malfunction are the main concerns in regard to pacemaker reutilization, yet many studies have shown that pacemaker reuse is not associated with increased infection risk or higher mortality compared with new device implantation. Under the right circumstances, the ethical and legal bases for pacemaker reutilization are supported. PMHYH is a proof of concept pacemaker donation initiative that has allowed funeral home and crematory directors to send explanted devices to an academic center for evaluation and re-sterilization before donation to underserved patients in LMICs. The time is now to pursue large-scale studies and trials of pacemaker reuse for the betterment of society. PMHYH is leading the way in the effort and is poised to conduct a prospective randomized, non-inferiority, multicenter study to confirm the clinical efficacy and safety of pacemaker reuse, for clinical and legal support. PMID:28515847
Pacemaker explosions in crematoria: problems and possible solutions
Gale, Christopher P; Mulley, Graham P
2002-01-01
The number of artificial cardiac pacemakers is increasing, as is the number of bodies being cremated. Because of the explosive potential of pacemakers when heated, a statutory question on the cremation form asks whether the deceased has a pacemaker and if so whether it has been removed. We sent a questionnaire to all the crematoria in the UK enquiring about the frequency, consequences and prevention of pacemaker explosions. We found that about half of all crematoria in the UK experience pacemaker explosions, that pacemaker explosions may cause structural damage and injury and that most crematoria staff are unaware of the explosive potential of implantable cardiac defibrillators. Crematoria staff rely on the accurate completion of cremation forms, and doctors who sign cremation forms have a legal obligation to provide such information. PMID:12091510
Initial Experience With Ultra High-Density Mapping of Human Right Atria.
Bollmann, Andreas; Hilbert, Sebastian; John, Silke; Kosiuk, Jedrzej; Hindricks, Gerhard
2016-02-01
Recently, an automatic, high-resolution mapping system has been presented to accurately and quickly identify right atrial geometry and activation patterns in animals, but human data are lacking. This study aims to assess the clinical feasibility and accuracy of high-density electroanatomical mapping of various RA arrhythmias. Electroanatomical maps of the RA (35 partial and 24 complete) were created in 23 patients using a novel mini-basket catheter with 64 electrodes and automatic electrogram annotation. Median acquisition time was 6:43 minutes (0:39-23:05 minutes) with shorter times for partial (4.03 ± 4.13 minutes) than for complete maps (9.41 ± 4.92 minutes). During mapping 3,236 (710-16,306) data points were automatically annotated without manual correction. Maps obtained during sinus rhythm created geometry consistent with CT imaging and demonstrated activation originating at the middle to superior crista terminalis, while maps during CS pacing showed right atrial activation beginning at the infero-septal region. Activation patterns were consistent with cavotricuspid isthmus-dependent atrial flutter (n = 4), complex reentry tachycardia (n = 1), or ectopic atrial tachycardia (n = 2). His bundle and fractionated potentials in the slow pathway region were automatically detected in all patients. Ablation of the cavotricuspid isthmus (n = 9), the atrio-ventricular node (n = 2), atrial ectopy (n = 2), and the slow pathway (n = 3) was successfully and safely performed. RA mapping with this automatic high-density mapping system is fast, feasible, and safe. It is possible to reproducibly identify propagation of atrial activation during sinus rhythm, various tachycardias, and also complex reentrant arrhythmias. © 2015 Wiley Periodicals, Inc.
21 CFR 870.3700 - Pacemaker programmers.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker programmers. 870.3700 Section 870.3700...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3700 Pacemaker programmers. (a) Identification. A pacemaker programmer is a device used to change noninvasively one or more of...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.5550 - External transcutaneous cardiac pacemaker (noninvasive).
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External transcutaneous cardiac pacemaker... § 870.5550 External transcutaneous cardiac pacemaker (noninvasive). (a) Identification. An external transcutaneous cardiac pacemaker (noninvasive) is a device used to supply a periodic electrical pulse intended to...
21 CFR 870.5550 - External transcutaneous cardiac pacemaker (noninvasive).
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External transcutaneous cardiac pacemaker... § 870.5550 External transcutaneous cardiac pacemaker (noninvasive). (a) Identification. An external transcutaneous cardiac pacemaker (noninvasive) is a device used to supply a periodic electrical pulse intended to...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...
21 CFR 870.3630 - Pacemaker generator function analyzer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker generator function analyzer. 870.3630... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3630 Pacemaker generator function analyzer. (a) Identification. A pacemaker generator function analyzer is a device that is...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...
21 CFR 870.3700 - Pacemaker programmers.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker programmers. 870.3700 Section 870.3700...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3700 Pacemaker programmers. (a) Identification. A pacemaker programmer is a device used to change noninvasively one or more of...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.5550 - External transcutaneous cardiac pacemaker (noninvasive).
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External transcutaneous cardiac pacemaker... § 870.5550 External transcutaneous cardiac pacemaker (noninvasive). (a) Identification. An external transcutaneous cardiac pacemaker (noninvasive) is a device used to supply a periodic electrical pulse intended to...
21 CFR 870.3720 - Pacemaker electrode function tester.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...
21 CFR 870.3700 - Pacemaker programmers.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker programmers. 870.3700 Section 870.3700...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3700 Pacemaker programmers. (a) Identification. A pacemaker programmer is a device used to noninvasively change one or more of...
21 CFR 870.3630 - Pacemaker generator function analyzer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker generator function analyzer. 870.3630... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3630 Pacemaker generator function analyzer. (a) Identification. A pacemaker generator function analyzer is a device that is...
21 CFR 870.3630 - Pacemaker generator function analyzer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker generator function analyzer. 870.3630... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3630 Pacemaker generator function analyzer. (a) Identification. A pacemaker generator function analyzer is a device that is...
21 CFR 870.3730 - Pacemaker service tools.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...
21 CFR 870.3630 - Pacemaker generator function analyzer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker generator function analyzer. 870.3630... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3630 Pacemaker generator function analyzer. (a) Identification. A pacemaker generator function analyzer is a device that is...
21 CFR 870.5550 - External transcutaneous cardiac pacemaker (noninvasive).
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External transcutaneous cardiac pacemaker... § 870.5550 External transcutaneous cardiac pacemaker (noninvasive). (a) Identification. An external transcutaneous cardiac pacemaker (noninvasive) is a device used to supply a periodic electrical pulse intended to...
21 CFR 870.3700 - Pacemaker programmers.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker programmers. 870.3700 Section 870.3700...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3700 Pacemaker programmers. (a) Identification. A pacemaker programmer is a device used to noninvasively change one or more of...
21 CFR 870.5550 - External transcutaneous cardiac pacemaker (noninvasive).
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External transcutaneous cardiac pacemaker... § 870.5550 External transcutaneous cardiac pacemaker (noninvasive). (a) Identification. An external transcutaneous cardiac pacemaker (noninvasive) is a device used to supply a periodic electrical pulse intended to...
Evaluation of the effects of electric fields on implanted cardiac pacemakers. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moss, A.J.; Carstensen, E.
1985-02-01
The effects of extra high voltage (EHV) transmission line electric fields on pacemaker function were evaluated in 11 patients with seven different implanted pacemaker models from four manufacturers. Alteration in pacemaker function was demonstrated in five unipolar units (three different models) from two manufacturers during exposure to electric fields ranging from 2 to 9 kV/m, with total body currents from 47 to 175 ..mu..A. These electric fields and body currents are representative of values that can be encountered by individuals standing beneath EHV transmission lines. Transient alterations in pacemaker function observed in this study included inappropriate triggered activity, inhibition ofmore » impulse generation, reduction in rate, and reversion from demand to asynchronous mode. Electromagnetic interference from high voltage transmission lines can induce alterations in pacemaker function in certain designs of these devices. However, pacemaker manufacturers can incorporate appropriate circuits in the pacemaker design to eliminate this problem. 8 references.« less
NASA Astrophysics Data System (ADS)
Aghighi, Alireza; Comtois, Philippe
2017-09-01
Self-organization of spontaneous activity of a network of active elements is important to the general theory of reaction-diffusion systems as well as for pacemaking activity to initiate beating of the heart. Monolayer cultures of neonatal rat ventricular myocytes, consisting of resting and pacemaker cells, exhibit spontaneous activation of their electrical activity. Similarly, one proposed approach to the development of biopacemakers as an alternative to electronic pacemakers for cardiac therapy is based on heterogeneous cardiac cells with resting and spontaneously beating phenotypes. However, the combined effect of pacemaker characteristics, density, and spatial distribution of the pacemaker cells on spontaneous activity is unknown. Using a simple stochastic pattern formation algorithm, we previously showed a clear nonlinear dependency of spontaneous activity (occurrence and amplitude of spontaneous period) on the spatial patterns of pacemaker cells. In this study, we show that this behavior is dependent on the pacemaker cell characteristics, with weaker pacemaker cells requiring higher density and larger clusters to sustain multicellular activity. These multicellular structures also demonstrated an increased sensitivity to voltage noise that favored spontaneous activity at lower density while increasing temporal variation in the period of activity. This information will help researchers overcome the current limitations of biopacemakers.
Nonlinear dynamics, chaos and complex cardiac arrhythmias
NASA Technical Reports Server (NTRS)
Glass, L.; Courtemanche, M.; Shrier, A.; Goldberger, A. L.
1987-01-01
Periodic stimulation of a nonlinear cardiac oscillator in vitro gives rise to complex dynamics that is well described by one-dimensional finite difference equations. As stimulation parameters are varied, a large number of different phase-locked and chaotic rhythms is observed. Similar rhythms can be observed in the intact human heart when there is interaction between two pacemaker sites. Simplified models are analyzed, which show some correspondence to clinical observations.
21 CFR 870.1750 - External programmable pacemaker pulse generator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External programmable pacemaker pulse generator. 870.1750 Section 870.1750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... External programmable pacemaker pulse generator. (a) Identification. An external programmable pacemaker...
21 CFR 870.1750 - External programmable pacemaker pulse generator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External programmable pacemaker pulse generator. 870.1750 Section 870.1750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... External programmable pacemaker pulse generator. (a) Identification. An external programmable pacemaker...
21 CFR 870.1750 - External programmable pacemaker pulse generator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External programmable pacemaker pulse generator. 870.1750 Section 870.1750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... External programmable pacemaker pulse generator. (a) Identification. An external programmable pacemaker...
21 CFR 870.1750 - External programmable pacemaker pulse generator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External programmable pacemaker pulse generator. 870.1750 Section 870.1750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... External programmable pacemaker pulse generator. (a) Identification. An external programmable pacemaker...
21 CFR 870.1750 - External programmable pacemaker pulse generator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External programmable pacemaker pulse generator. 870.1750 Section 870.1750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... External programmable pacemaker pulse generator. (a) Identification. An external programmable pacemaker...
21 CFR 870.3710 - Pacemaker repair or replacement material.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...
21 CFR 870.3670 - Pacemaker charger.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker charger. 870.3670 Section 870.3670 Food... DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3670 Pacemaker charger. (a) Identification. A pacemaker charger is a device used transcutaneously to recharge the batteries of a rechargeable...
21 CFR 870.3670 - Pacemaker charger.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker charger. 870.3670 Section 870.3670 Food... DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3670 Pacemaker charger. (a) Identification. A pacemaker charger is a device used transcutaneously to recharge the batteries of a rechargeable...
21 CFR 870.3710 - Pacemaker repair or replacement material.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...
21 CFR 870.3670 - Pacemaker charger.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker charger. 870.3670 Section 870.3670 Food... DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3670 Pacemaker charger. (a) Identification. A pacemaker charger is a device used transcutaneously to recharge the batteries of a rechargeable...
21 CFR 870.3710 - Pacemaker repair or replacement material.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...
21 CFR 870.3670 - Pacemaker charger.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker charger. 870.3670 Section 870.3670 Food... DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3670 Pacemaker charger. (a) Identification. A pacemaker charger is a device used transcutaneously to recharge the batteries of a rechargeable...
21 CFR 870.3710 - Pacemaker repair or replacement material.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...
Kodama, I; Anno, T; Sudo, Y; Satake, N; Shibata, S
1989-05-01
Effects of the cardiotonic agent FK664, 6-(3, 4-dimethoxy-phenyl)-1-ethyl-4-mesitylimino-3-methyl-3,4-dihydro-2 (1H)-pyrimidone, on isolated guinea pig ventricular muscles and rabbit sinus node pacemaker cells were studied using micro-electrode techniques. In ventricular muscles driven at 0.5-1.0 Hz, FK664 above 3 mumol.litre-1 caused an increase in contractile force and a shortening of time to peak tension. This positive inotropic effect of FK664 was accompanied by a slight elevation of the early plateau phase of the action potential, while other action potential variables were unaffected. The change in contractile force induced by FK664 was abolished in a low Ca2+ medium (0.12 mmol.litre-1) or by treatment with ryanodine (2 mumol.litre-1), whereas it was relatively well preserved in the preparations pretreated with nefedipine (1 mumol.litre-1). The slow action potentials induced by isoprenaline (0.3 mumol.litre-1) in high K+ medium (30 mmol.litre-1) and the slow inward current measured by single sucrose gap voltage clamp at a holding potential of -40 mV were unaffected by FK664. In sinus node pacemaker cells, FK664 (1-10 mumol.litre-1) caused a dose dependent acceleration of phase 4 depolarisation and a shortening of spontaneous firing cycle length. This positive chronotropic effect of FK664 was markedly inhibited in a low Ca2+ medium (0.3 mmol.litre-1). These findings suggest that FK664 has positive inotropic and chronotropic effects on the heart, due to an enhancement of transsarcolemmal calcium influx through the low threshold, dihydropyridine insensitive Ca2+ channel population.
Use of antiarrhythmic drugs in elderly patients.
Lee, Hon-Chi; Tl Huang, Kristin; Shen, Win-Kuang
2011-09-01
Human aging is a global issue with important implications for current and future incidence and prevalence of health conditions and disability. Cardiac arrhythmias, including atrial fibrillation, sudden cardiac death, and bradycardia requiring pacemaker placement, all increase exponentially after the age of 60. It is important to distinguish between the normal, physiological consequences of aging on cardiac electrophysiology and the abnormal, pathological alterations. The age-related cardiac changes include ventricular hypertrophy, senile amyloidosis, cardiac valvular degenerative changes and annular calcification, fibrous infiltration of the conduction system, and loss of natural pacemaker cells and these changes could have a profound effect on the development of arrhythmias. The age-related cardiac electrophysiological changes include up- and down-regulation of specific ion channel expression and intracellular Ca(2+) overload which promote the development of cardiac arrhythmias. As ion channels are the substrates of antiarrhythmic drugs, it follows that the pharmacokinetics and pharmacodynamics of these drugs will also change with age. Aging alters the absorption, distribution, metabolism, and elimination of antiarrhythmic drugs, so liver and kidney function must be monitored to avoid potential adverse drug effects, and antiarrhythmic dosing may need to be adjusted for age. Elderly patients are also more susceptible to the side effects of many antiarrhythmics, including bradycardia, orthostatic hypotension, urinary retention, and falls. Moreover, the choice of antiarrhythmic drugs in the elderly patient is frequently complicated by the presence of co-morbid conditions and by polypharmacy, and the astute physician must pay careful attention to potential drug-drug interactions. Finally, it is important to remember that the use of antiarrhythmic drugs in elderly patients must be individualized and tailored to each patient's physiology, disease processes, and medication regimen.
Vamos, Mate; Erath, Julia W; Benz, Alexander P; Bari, Zsolt; Duray, Gabor Z; Hohnloser, Stefan H
2017-03-01
Two leadless pacemaker (PM) systems were recently developed to avoid pocket- and lead-related complications. As leadless PMs are implanted with a large delivery catheter, cardiac perforation remains a major safety concern. We aimed to provide a literature review on incidence of cardiac perforation with conventional and with leadless PM systems. A systematic review over the last 25 years for studies reporting data on PM lead perforation was performed. Findings were synthesized descriptively. Where control groups were available, data were meta-analyzed to identify important clinical risk factors. A total of 28 studies comprising 60,744 patients undergoing conventional PM implantation were analyzed. The incidence of lead perforation ranged from 0% to 6.37% (mean 0.82%, weighted mean 0.31%, median of 0.40%). There was no significant difference in perforation risk between atrial and ventricular electrodes (POR 0.72, 95% confidence interval [CI], 0.28-1.87, P = 0.50) and between MRI conditional and conventional leads (POR 5.93, 95% CI, 0.72-48.76, P = 0.10). The use of active fixation leads (POR 4.25, 95% CI, 1.00-17.95, P = 0.05) and utilization of DDD versus VVI PM systems (POR 3.50, 95% CI, 1.48-8.28, P < 0.01) were associated with higher rates of perforation. In the 2 leadless PM studies, the incidence of cardiac perforation was 1.52% for each. PM lead perforation rates vary in individual studies with an overall low incidence. Leadless PMs seem to be associated with a slightly higher perforation risk, most likely reflecting a learning curve effect of this novel technology. © 2016 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frazier, M.J.
1980-08-01
The electromagnetic fields associated with HVDC converters and transmission lines constitute a unique environment for persons with implanted cardiac pacemakers. A measurement program has been conducted to assess the potential interfering effects of these harmonically rich fields on implanted pacemakers. The experimental procedures that were employed take into account the combined effects of the electric and magnetic fields. The effect of the resulting body current on the response of six pacemakers was assessed in the laboratory, using a previously developed model to relate body current to pacemaker pickup voltage. The results show that R-wave pacemaker reversion can be expected atmore » some locations within the converter facility, but that a large safety margin for unperturbed pacemaker operation exists beneath the transmission lines.« less
Nazarian, Saman; Hansford, Rozann; Roguin, Ariel; Goldsher, Dorith; Zviman, Menekhem M.; Lardo, Albert C.; Caffo, Brian S.; Frick, Kevin D.; Kraut, Michael A.; Kamel, Ihab R.; Calkins, Hugh; Berger, Ronald D.; Bluemke, David A.; Halperin, Henry R.
2015-01-01
Background Magnetic resonance imaging (MRI) is avoided in most patients with implanted cardiac devices because of safety concerns. Objective To define the safety of a protocol for MRI at the commonly used magnetic strength of 1.5 T in patients with implanted cardiac devices. Design Prospective nonrandomized trial. (ClinicalTrials.gov registration number: NCT01130896) Setting One center in the United States (94% of examinations) and one in Israel. Patients 438 patients with devices (54% with pacemakers and 46% with defibrillators) who underwent 555 MRI studies. Intervention Pacing mode was changed to asynchronous for pacemaker-dependent patients and to demand for others. Tachy-arrhythmia functions were disabled. Blood pressure, electrocardiography, oximetry, and symptoms were monitored by a nurse with experience in cardiac life support and device programming who had immediate backup from an electrophysiologist. Measurements Activation or inhibition of pacing, symptoms, and device variables. Results In 3 patients (0.7% [95% CI, 0% to 1.5%]), the device reverted to a transient back-up programming mode without long-term effects. Right ventricular (RV) sensing (median change, 0 mV [interquartile range {IQR}, −0.7 to 0 V]) and atrial and right and left ventricular lead impedances (median change, −2 Ω[IQR, −13 to 0 Ω], −4 Ω [IQR, −16 to 0 Ω], and −11 Ω [IQR, −40 to 0 Ω], respectively) were reduced immediately after MRI. At long-term follow-up (61% of patients), decreased RV sensing (median, 0 mV, [IQR, −1.1 to 0.3 mV]), decreased RV lead impedance (median, −3 Ω, [IQR, −29 to 15 Ω]), increased RV capture threshold (median, 0 V, IQR, [0 to 0.2 Ω]), and decreased battery voltage (median, −0.01 V, IQR, −0.04 to 0 V) were noted. The observed changes did not require device revision or reprogramming. Limitations Not all available cardiac devices have been tested. Long-term in-person or telephone follow-up was unavailable in 43 patients (10%), and some data were missing. Those with missing long-term capture threshold data had higher baseline right atrial and right ventricular capture thresholds and were more likely to have undergone thoracic imaging. Defibrillation threshold testing and random assignment to a control group were not performed. Conclusion With appropriate precautions, MRI can be done safely in patients with selected cardiac devices. Because changes in device variables and programming may occur, electrophysiologic monitoring during MRI is essential. Primary Funding Source National Institutes of Health. PMID:21969340
21 CFR 870.3650 - Pacemaker polymeric mesh bag.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker polymeric mesh bag. 870.3650 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3650 Pacemaker polymeric mesh bag. (a) Identification. A pacemaker polymeric mesh bag is an implanted device used to hold a...
21 CFR 870.3650 - Pacemaker polymeric mesh bag.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker polymeric mesh bag. 870.3650 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3650 Pacemaker polymeric mesh bag. (a) Identification. A pacemaker polymeric mesh bag is an implanted device used to hold a...
21 CFR 870.3690 - Pacemaker test magnet.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker test magnet. 870.3690 Section 870.3690...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3690 Pacemaker test magnet. (a) Identification. A pacemaker test magnet is a device used to test an inhibited or triggered type...
21 CFR 870.3690 - Pacemaker test magnet.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker test magnet. 870.3690 Section 870.3690...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3690 Pacemaker test magnet. (a) Identification. A pacemaker test magnet is a device used to test an inhibited or triggered type...
21 CFR 870.3690 - Pacemaker test magnet.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pacemaker test magnet. 870.3690 Section 870.3690...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3690 Pacemaker test magnet. (a) Identification. A pacemaker test magnet is a device used to test an inhibited or triggered type...
21 CFR 870.3610 - Implantable pacemaker pulse generator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Implantable pacemaker pulse generator. 870.3610 Section 870.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... pacemaker pulse generator. (a) Identification. An implantable pacemaker pulse generator is a device that has...
21 CFR 870.3650 - Pacemaker polymeric mesh bag.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pacemaker polymeric mesh bag. 870.3650 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3650 Pacemaker polymeric mesh bag. (a) Identification. A pacemaker polymeric mesh bag is an implanted device used to hold a...
21 CFR 870.3690 - Pacemaker test magnet.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pacemaker test magnet. 870.3690 Section 870.3690...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3690 Pacemaker test magnet. (a) Identification. A pacemaker test magnet is a device used to test an inhibited or triggered type...
21 CFR 870.3650 - Pacemaker polymeric mesh bag.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pacemaker polymeric mesh bag. 870.3650 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3650 Pacemaker polymeric mesh bag. (a) Identification. A pacemaker polymeric mesh bag is an implanted device used to hold a...
Radiation effect on implanted pacemakers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pourhamidi, A.H.
1983-10-01
It was previously thought that diagnostic or therapeutic ionizing radiation did not have an adverse effect on the function of cardiac pacemakers. Recently, however, some authors have reported damaging effect of therapeutic radiation on cardiac pulse generators. An analysis of a recently-extracted pacemaker documented the effect of radiation on the pacemaker pulse generator.
NASA Technical Reports Server (NTRS)
1980-01-01
St. Jude Medical's Cardiac Rhythm Management Division, formerly known as Pacesetter Systems, Inc., incorporated Apollo technology into the development of the programmable pacemaker system. This consists of the implantable pacemaker together with a physician's console containing the programmer and a data printer. Physician can communicate with patient's pacemaker by means of wireless telemetry signals transmitted through the communicating head held over the patient's chest. Where earlier pacemakers deliver a fixed type of stimulus once implanted, Programalith enables surgery free "fine tuning" of device to best suit the patient's changing needs.
Bharat, Vijaya
2004-01-01
The incidence of permanent pacemaker-related complications is reducing due to advancement of technology and increasing operator experience. There are only few series from India reporting the annual complication rates from a single center over the years. This is a series of 782 pacemakers implanted over 20 years in a secondary healthcare set-up. Eighty-two patients underwent redo surgery, either for a procedure-related complication (n=34) or for replacement of a malfunctioning/end-of-life pacemaker (n=48). Through critical analysis and corrective measures, all the procedural complications were reduced to less than 4% of the annual implantations. The introduction of a pacemaker follow-up clinic contributed to reducing the rate of elective replacement for battery depletion from 19.17% of the implanted VVI pacemakers to 0.63%. Despite being a low-volume center, with less than 100 pacemakers implanted annually, the performance of our pacing practice has shown continuous improvement.
Cerebrovascular accidents in adult patients with congenital heart disease.
Hoffmann, A; Chockalingam, P; Balint, O H; Dadashev, A; Dimopoulos, K; Engel, R; Schmid, M; Schwerzmann, M; Gatzoulis, M A; Mulder, B; Oechslin, E
2010-08-01
To investigate the prevalence and characteristics of cerebrovascular accidents (CVA) in a large population of adults with congenital heart disease (CHD). In a retrospective analysis of aggregated European and Canadian databases a total population of 23 153 patients with CHD was followed up to the age of 16-91 years (mean 36.4 years). Among them, 458 patients (2.0%) had one or more CVA, with an estimated event rate of 0.05% per patient-year. Permanent neurological sequelae were noted in 116 patients (25.3%). The prevalence of CVA in selected diagnostic categories was as follows: open atrial septal defect 93/2351 (4.0%); closed atrial or ventricular septal defect 57/4035 (1.4%); corrected tetralogy of Fallot 52/2196 (2.4%); Eisenmenger physiology 24/467 (5.1%); other cyanotic 50/215 (23.3%); mechanical prostheses (29/882 (3.3%). Associated conditions in patients with CVA were absence of sinus rhythm (25%), transvenous pacemakers (7%), endocarditis (2%), cardiac surgery (11%) and catheter intervention (2%), but with the exception of absent sinus rhythm these were not significantly more prevalent in patients with CVA. CVA are a major contributor to morbidity in this young population despite absence of classical cardiovascular risk factors. Although the prevalence of CVA in patients with CHD appears low, it is 10-100 times higher than expected in control populations of comparable age. Residua occur in a strong minority of patients. The subjects at highest risk are those patients with CHD with cyanotic lesions, in whom the prevalence is over 10-fold above the average.
Wenckebach upper rate response in single chamber pacemaker.
Barold, S S
2000-07-01
The Medtronic Minix pacemaker during normal function in the VVT mode was found to exhibit a Wenckenbach upper rate response similar to that of dual chamber devices. This behavior occurred only when the upper rate interval was longer than the pacemaker refractory period. In a single chamber device this response may simulate pacemaker malfunction.
Proton Beam Therapy Interference With Implanted Cardiac Pacemakers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oshiro, Yoshiko; Sugahara, Shinji; Noma, Mio
2008-11-01
Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined beforemore » and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.« less
Trends in Cardiac Pacemaker Batteries
Mallela, Venkateswara Sarma; Ilankumaran, V; Rao, N.Srinivasa
2004-01-01
Batteries used in Implantable cardiac pacemakers-present unique challenges to their developers and manufacturers in terms of high levels of safety and reliability. In addition, the batteries must have longevity to avoid frequent replacements. Technological advances in leads/electrodes have reduced energy requirements by two orders of magnitude. Micro-electronics advances sharply reduce internal current drain concurrently decreasing size and increasing functionality, reliability, and longevity. It is reported that about 600,000 pacemakers are implanted each year worldwide and the total number of people with various types of implanted pacemaker has already crossed 3 million. A cardiac pacemaker uses half of its battery power for cardiac stimulation and the other half for housekeeping tasks such as monitoring and data logging. The first implanted cardiac pacemaker used nickel-cadmium rechargeable battery, later on zinc-mercury battery was developed and used which lasted for over 2 years. Lithium iodine battery invented and used by Wilson Greatbatch and his team in 1972 made the real impact to implantable cardiac pacemakers. This battery lasts for about 10 years and even today is the power source for many manufacturers of cardiac pacemakers. This paper briefly reviews various developments of battery technologies since the inception of cardiac pacemaker and presents the alternative to lithium iodine battery for the near future. PMID:16943934
Next-generation pacemakers: from small devices to biological pacemakers.
Cingolani, Eugenio; Goldhaber, Joshua I; Marbán, Eduardo
2018-03-01
Electrogenesis in the heart begins in the sinoatrial node and proceeds down the conduction system to originate the heartbeat. Conduction system disorders lead to slow heart rates that are insufficient to support the circulation, necessitating implantation of electronic pacemakers. The typical electronic pacemaker consists of a subcutaneous generator and battery module attached to one or more endocardial leads. New leadless pacemakers can be implanted directly into the right ventricular apex, providing single-chamber pacing without a subcutaneous generator. Modern pacemakers are generally reliable, and their programmability provides options for different pacing modes tailored to specific clinical needs. Advances in device technology will probably include alternative energy sources and dual-chamber leadless pacing in the not-too-distant future. Although effective, current electronic devices have limitations related to lead or generator malfunction, lack of autonomic responsiveness, undesirable interactions with strong magnetic fields, and device-related infections. Biological pacemakers, generated by somatic gene transfer, cell fusion, or cell transplantation, provide an alternative to electronic devices. Somatic reprogramming strategies, which involve transfer of genes encoding transcription factors to transform working myocardium into a surrogate sinoatrial node, are furthest along in the translational pipeline. Even as electronic pacemakers become smaller and less invasive, biological pacemakers might expand the therapeutic armamentarium for conduction system disorders.
Moreno, Raúl; Calvo, Luis; Sánchez-Recalde, Angel; Galeote, Guillermo; Jiménez-Valero, Santiago; López, Teresa; Plaza, Ignacio; González-Davia, Rosa; Ramírez, Ulises; Mesa, Jose Maria; Moreno-Gomez, Isidro; López-Sendón, José-Luis
2015-11-01
A permanent pacemaker is frequently needed after transcatheter aortic valve implantation, but the available data are mainly on the CoreValve system. To evaluate the need for new permanent pacemaker after implantation of the Edwards Sapien device, as well as related factors. We included the first 100 patients treated with the Edwards Sapien device at our institution. Of these, 12 had a permanent pacemaker before the procedure, and thus our study population was the remaining 88 patients. A permanent pacemaker was indicated in eight patients (9.1%) during hospitalization or at 30 days. After discharge, another four patients needed a pacemaker (at 42 days and three, 18, and 30 months). Two variables were associated with the need for pacemaker during hospitalization: previous dialysis (13% vs. 1%, p=0.042) and complete right bundle branch block before the procedure (25% vs. 5%, p=0.032). More than one month after the procedure, the characteristics associated with the need for pacemaker were plasma creatinine level (2.5±1.7 vs. 1.3±0.6 mg/dl, p=0.001) and previous myocardial infarction (50% vs. 10%, p=0.013). The rate of pacemaker implantation with the Edwards Sapien device was 9.1%. Right bundle branch block and dialysis were associated with this complication.
Liu, Tianxin; Mahesh, Guruswamy; Houl, Jerry H; Hardin, Paul E
2015-06-03
Circadian pacemaker neurons in the Drosophila brain control daily rhythms in locomotor activity. These pacemaker neurons can be subdivided into early or late groups depending on whether rhythms in period (per) and timeless (tim) expression are initiated at the first instar (L1) larval stage or during metamorphosis, respectively. Because CLOCK-CYCLE (CLK-CYC) heterodimers initiate circadian oscillator function by activating per and tim transcription, a Clk-GFP transgene was used to mark when late pacemaker neurons begin to develop. We were surprised to see that CLK-GFP was already expressed in four of five clusters of late pacemaker neurons during the third instar (L3) larval stage. CLK-GFP is only detected in postmitotic neurons from L3 larvae, suggesting that these four late pacemaker neuron clusters are formed before the L3 larval stage. A GFP-cyc transgene was used to show that CYC, like CLK, is also expressed exclusively in pacemaker neurons from L3 larval brains, demonstrating that CLK-CYC is not sufficient to activate per and tim in late pacemaker neurons at the L3 larval stage. These results suggest that most late pacemaker neurons develop days before novel factors activate circadian oscillator function during metamorphosis. Copyright © 2015 the authors 0270-6474/15/358662-10$15.00/0.
The nuclear pacemaker: Is renewed interest warranted
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parsonnet, V.; Berstein, A.D.; Perry, G.Y.
1990-10-01
From 1973 through 1987, 155 radioisotope-powered nuclear pacemakers were implanted in 132 patients at the Newark Beth Israel Medical Center. The longevity of the first 15 devices, all of which were fixed-rate (VOO) pacemakers, was significantly better than that of 15 lithium-chemistry demand (VVI) pacemakers used as control devices (p = 0.0002). Of the entire cohort of 155 nuclear pacemakers, 136 were VVI devices and 19 were VOO units. The patients with VOO pacemakers needed reoperations more often than did those with VVI pacemakers, chiefly for mode change (p less than 0.001). Power-source failure was observed in only 1 case,more » but 47 nuclear pacemakers were removed for other reasons, including component malfunction (15 units), mode change (12 units), high pacing thresholds (8 units) and lead or connector problems (5 units). The actuarial survival at 15 years was 99% for power sources and 82% for the entire pacing systems (pulse generators plus leads). The frequency of malignancy was similar to that of the population at large and primary tumor sites were randomly distributed. Deaths most commonly were due to cardiac causes (68%). Thus, nuclear pacemakers are safe and reliable and their greater initial cost appears to be offset by their longevity and the resulting decrease in the frequency of reoperations. It is reasonable to suggest that further use be made of long-lasting nuclear power sources for modern pacemakers and other implantable rhythm-management devices.« less
E AND M CIRCADIAN PACEMAKER NEURONS USE DIFFERENT PDF RECEPTOR SIGNALOSOME COMPONENTS IN DROSOPHILA
Duvall, Laura B.
2014-01-01
We used real-time imaging to detect cAMP levels in neurons of intact fly brains to study mechanisms of circadian pacemaker synchronization by the neuropeptide PDF in Drosophila. PDF receptor (PDF-R) is expressed by both M (sLNv) and E (LNd) pacemaker sub-classes and is coupled to Gsα in both cases. We previously reported that PDF-R in M pacemakers elevates cAMP levels by activating the ortholog of mammalian Adenylate Cyclase 3 (AC3), but that AC3 disruptions had no effect on E pacemaker sensitivity to PDF. Here we show that PDF-R in E pacemakers activates a different AC isoform, AC78C, an ortholog of mammalian AC8. Knockdown of AC78C by transgenic RNAi substantially reduces, but does not completely abrogate, PDF responses in these E pacemakers. The knockdown effect is intact when restricted to mature stages, suggesting a physiological and not a development role for AC78C in E pacemakers. The AC78C phenotype is rescued by over-expression of AC78C, but not by over-expression of the rutabaga AC. AC78C over-expression does not disrupt PDF responses in these E pacemakers, and neither AC78C knockdown nor its over-expression disrupted locomotor rhythms. Finally, knockdown of two AKAPs, nervy and AKAP 200 partially reduces LNd PDF responses. These findings begin to identify the components of E pacemaker PDF-R signalosomes and indicate they are distinct from PDF-R signalosomes in M pacemakers: we propose they contain AC78C and at least one other AC. PMID:23929551
E and M circadian pacemaker neurons use different PDF receptor signalosome components in drosophila.
Duvall, Laura B; Taghert, Paul H
2013-08-01
We used real-time imaging to detect cAMP levels in neurons of intact fly brains to study the mechanisms of circadian pacemaker synchronization by the neuropeptide pigment dispersing factor (PDF) in Drosophila. PDF receptor (PDF-R) is expressed by both M (sLNv) and E (LNd) pacemaker subclasses and is coupled to G(sα) in both cases. We previously reported that PDF-R in M pacemakers elevates cAMP levels by activating the ortholog of mammalian adenylate cyclase 3 (AC3) but that AC3 disruptions had no effect on E pacemaker sensitivity to PDF. Here, we show that PDF-R in E pacemakers activates a different AC isoform, AC78C, an ortholog of mammalian AC8. Knockdown of AC78C by transgenic RNAi substantially reduces, but does not completely abrogate, PDF responses in these E pacemakers. The knockdown effect is intact when restricted to mature stages, suggesting a physiological and not a development role for AC78C in E pacemakers. The AC78C phenotype is rescued by the overexpression of AC78C but not by overexpression of the rutabaga AC. AC78C overexpression does not disrupt PDF responses in these E pacemakers, and neither AC78C knockdown nor its overexpression disrupted locomotor rhythms. Finally, knockdown of 2 AKAPs, nervy and AKAP200, partially reduces LNd PDF responses. These findings begin to identify the components of E pacemaker PDF-R signalosomes and indicate that they are distinct from PDF-R signalosomes in M pacemakers: we propose they contain AC78C and at least 1 other AC.
The pacemaker-twiddler's syndrome: an infrequent cause of pacemaker failure.
Salahuddin, Mohammad; Cader, Fathima Aaysha; Nasrin, Sahela; Chowdhury, Mashhud Zia
2016-01-20
The pacemaker-twiddler's syndrome is an uncommon cause of pacemaker malfunction. It occurs due to unintentional or deliberate manipulation of the pacemaker pulse generator within its skin pocket by the patient. This causes coiling of the lead and its dislodgement, resulting in failure of ventricular pacing. More commonly reported among elderly females with impaired cognition, the phenomenon usually occurs in the first year following pacemaker implantation. Treatment involves repositioning of the dislodged leads and suture fixation of the lead and pulse generator within its pocket. An 87 year old Bangladeshi lady who underwent a single chamber ventricular pacemaker (VVI mode: i.e. ventricle paced, ventricle sensed, inhibitory mode) implantation with the indication of complete heart block, and presented to us again 7 weeks later, with syncopal attacks. She admitted to repeatedly manipulating the pacemaker generator in her left pectoral region. Physical examination revealed a heart rate of 42 beats/minute, blood pressure 140/80 mmHg and bilateral crackles on lung auscultation. She had no cognitive deficit. An immediate electrocardiogram showed complete heart block with pacemaker spikes and failure to capture. Chest X-ray showed coiled and retracted right ventricular lead and rotated pulse generator. An emergent temporary pace maker was set at a rate of 60 beats per minute. Subsequently, she underwent successful lead repositioning with strong counselling to avoid further twiddling. Twiddler's syndrome should be considered as a cause of pacemaker failure in elderly patients presenting with bradyarrythmias following pacemaker implantation. Chest X-ray and electrocardiograms are simple and easily-available first line investigations for its diagnosis. Lead repositioning is required, however proper patient education and counselling against further manipulation is paramount to long-term management.
Varela, Marta; Hancox, Jules C.; Aslanidi, Oleg V.
2016-01-01
Anti-arrhythmic drug therapy is a frontline treatment for atrial fibrillation (AF), but its success rates are highly variable. This is due to incomplete understanding of the mechanisms of action of specific drugs on the atrial substrate at different stages of AF progression. We aimed to elucidate the role of cellular, tissue and organ level atrial heterogeneities in the generation of a re-entrant substrate during AF progression, and their modulation by the acute action of selected anti-arrhythmic drugs. To explore the complex cell-to-organ mechanisms, a detailed biophysical models of the entire 3D canine atria was developed. The model incorporated atrial geometry and fibre orientation from high-resolution micro-computed tomography, region-specific atrial cell electrophysiology and the effects of progressive AF-induced remodelling. The actions of multi-channel class III anti-arrhythmic agents vernakalant and amiodarone were introduced in the model by inhibiting appropriate ionic channel currents according to experimentally reported concentration-response relationships. AF was initiated by applied ectopic pacing in the pulmonary veins, which led to the generation of localized sustained re-entrant waves (rotors), followed by progressive wave breakdown and rotor multiplication in both atria. The simulated AF scenarios were in agreement with observations in canine models and patients. The 3D atrial simulations revealed that a re-entrant substrate was typically provided by tissue regions of high heterogeneity of action potential duration (APD). Amiodarone increased atrial APD and reduced APD heterogeneity and was more effective in terminating AF than vernakalant, which increased both APD and APD dispersion. In summary, the initiation and sustenance of rotors in AF is linked to atrial APD heterogeneity and APD reduction due to progressive remodelling. Our results suggest that anti-arrhythmic strategies that increase atrial APD without increasing its dispersion are effective in terminating AF. PMID:27984585
Alday, Erick A. Perez; Colman, Michael A.; Langley, Philip; Butters, Timothy D.; Higham, Jonathan; Workman, Antony J.; Hancox, Jules C.; Zhang, Henggui
2015-01-01
Rapid atrial arrhythmias such as atrial fibrillation (AF) predispose to ventricular arrhythmias, sudden cardiac death and stroke. Identifying the origin of atrial ectopic activity from the electrocardiogram (ECG) can help to diagnose the early onset of AF in a cost-effective manner. The complex and rapid atrial electrical activity during AF makes it difficult to obtain detailed information on atrial activation using the standard 12-lead ECG alone. Compared to conventional 12-lead ECG, more detailed ECG lead configurations may provide further information about spatio-temporal dynamics of the body surface potential (BSP) during atrial excitation. We apply a recently developed 3D human atrial model to simulate electrical activity during normal sinus rhythm and ectopic pacing. The atrial model is placed into a newly developed torso model which considers the presence of the lungs, liver and spinal cord. A boundary element method is used to compute the BSP resulting from atrial excitation. Elements of the torso mesh corresponding to the locations of the placement of the electrodes in the standard 12-lead and a more detailed 64-lead ECG configuration were selected. The ectopic focal activity was simulated at various origins across all the different regions of the atria. Simulated BSP maps during normal atrial excitation (i.e. sinoatrial node excitation) were compared to those observed experimentally (obtained from the 64-lead ECG system), showing a strong agreement between the evolution in time of the simulated and experimental data in the P-wave morphology of the ECG and dipole evolution. An algorithm to obtain the location of the stimulus from a 64-lead ECG system was developed. The algorithm presented had a success rate of 93%, meaning that it correctly identified the origin of atrial focus in 75/80 simulations, and involved a general approach relevant to any multi-lead ECG system. This represents a significant improvement over previously developed algorithms. PMID:25611350
The effect of single engine fixed wing air transport on rate-responsive pacemakers.
De Rotte, A A; Van Der Kemp, P
1999-09-01
Insufficient information exists about the safety of patients with accelerometer-based rate-responsive pacemakers in air transport by general aviation aircraft. The response in pacing rate of two types of accelerometer-based rate-responsive pacemakers with data logging capabilities was studied during test flights with single engine fixed wing aircraft. Results were compared with the rate-response of these pacemakers during transportation by car and were also interpreted in respect to physiological heart rate response of aircrew during flights in single engine fixed wing aircraft. In addition, a continuous accelerometer readout was recorded during a turbulent phase of flight. This recording was used for a pacemaker-simulator experiment with maximal sensitive motion-sensor settings. Only a minor increase in pacing rate due to aircraft motion could be demonstrated during all phases of flight at all altitudes with the pacemakers programmed in the normal mode. This increase was of the same magnitude as induced during transport by car and would be of negligible influence on the performance of the individual pacemaker patient equipped with such a pacemaker. Moreover, simultaneous Holter monitoring of the pilots during these flights showed a similar rate-response in natural heart rate compared with the increase in pacing rate induced by aircraft motion in accelerometer-based rate-responsive pacemakers. No sensor-mediated pacemaker tachycardia was seen during any of these recordings. However, a 15% increase in pacing rate was induced by severe air turbulence. Programming the maximal sensitivity of the motion sensor into the pacemaker could, on the other hand, induce a significant increase in pacing rate as was demonstrated by the simulation experiments. These results seem to rule out potentially dangerous or adverse effects from motional or vibrational influences during transport in single engine fixed wing aircraft on accelerometer-based rate-responsive pacemakers with normal activity sensor settings.
Imaging congenital heart disease in adults
Kilner, P J
2011-01-01
Transthoracic echocardiography is the first-line modality for cardiovascular imaging in adults with congenital heart disease (ACHD). The windows of access that are possible with transthoracic echocardiography are, however, rarely adequate for all regions of interest. The choice of further imaging depends on the clinical questions that remain to be addressed. The strengths of MRI include comprehensive access and coverage, providing imaging of all parts of the right ventricle, the pulmonary arteries, pulmonary veins and aorta. Cine images and velocity maps are acquired in specifically aligned planes, with stacks of cines or dynamic contrast angiography providing more comprehensive coverage. Tissues can be characterised if necessary, and MRI provides relatively accurate measurements of biventricular function and volume flow. These parameters are important in the assessment and follow-up of adults after repairs for tetralogy of Fallot or transposition of the great arteries and after Fontan operations. The superior spatial resolution and rapid acquisition of CT are invaluable in selected situations, including the visualisation of anomalous coronary or aortopulmonary collateral arteries, the assessment of luminal patency after stenting and imaging in patients with pacemakers. Ionising radiation is, however, a concern in younger patients who may need repeated investigation. Adults with relatively complex conditions should ideally be imaged in a specialist ACHD centre, where dedicated echocardiographic and cardiovascular MRI services are a necessary facility. General radiologists should be aware of the nature and pathophysiology of congenital heart disease, and should be alert for previously undiagnosed cases presenting in adulthood, including cases of atrial septal defect, aortic coarctation, patent ductus arteriosus, double-chambered right ventricle and congenitally corrected transposition. PMID:22723533
García-Isla, Guadalupe; Olivares, Andy Luis; Silva, Etelvino; Nuñez-Garcia, Marta; Butakoff, Constantine; Sanchez-Quintana, Damian; G Morales, Hernán; Freixa, Xavier; Noailly, Jérôme; De Potter, Tom; Camara, Oscar
2018-05-08
The left atrial appendage (LAA) is a complex and heterogeneous protruding structure of the left atrium (LA). In atrial fibrillation patients, it is the location where 90% of the thrombi are formed. However, the role of the LAA in thrombus formation is not fully known yet. The main goal of this work is to perform a sensitivity analysis to identify the most relevant LA and LAA morphological parameters in atrial blood flow dynamics. Simulations were run on synthetic ellipsoidal left atria models where different parameters were individually studied: pulmonary veins and mitral valve dimensions; LAA shape; and LA volume. Our computational analysis confirmed the relation between large LAA ostia, low blood flow velocities and thrombus formation. Additionally, we found that pulmonary vein configuration exerted a critical influence on LAA blood flow patterns. These findings contribute to a better understanding of the LAA and to support clinical decisions for atrial fibrillation patients. Copyright © 2018 John Wiley & Sons, Ltd.
van Dijk, Joris D; Ottervanger, Jan Paul; Delnoy, Peter Paul H M; Lagerweij, Martine C M; Knollema, Siert; Slump, Cornelis H; Jager, Pieter L
2017-01-01
New X-ray technology providing new image processing techniques may reduce radiation exposure. The aim of this study was to quantify this radiation exposure reduction for patients during pacemaker and implantable cardioverter defibrillator (ICD) implantation. In this retrospective study, 1185 consecutive patients who had undergone de novo pacemaker or ICD implantation during a 2-year period were included. All implantations in the first year were performed using the reference technology (Allura Xper), whereas in the second year, the new X-ray technology (AlluraClarity) was used. Radiation exposure, expressed as the dose area product (DAP), was compared between the two time periods to determine the radiation exposure reduction for pacemaker and ICD implantations without cardiac resynchronization therapy (CRT) and with CRT. Procedure duration and contrast volume were used as measures to compare complexity and image quality. The study population consisted of 591 patients who had undergone an implantation using the reference technology, and 594 patients with the new X-ray technology. The two groups did not differ in age, gender, or body mass index. The DAP decreased with 69 % from 16.4 ± 18.5 to 5.2 ± 6.6 Gy cm 2 for the non-CRT implantations (p < 0.001). The DAP decreased with 75 % from 72.1 ± 60.0 to 17.8 ± 17.4 Gy cm 2 for the CRT implantations (p < 0.001). Nevertheless, procedure duration and contrast volume did not differ when using the new technology (p = 0.09 and p = 0.20, respectively). Introduction of new X-ray technology resulted in a radiation exposure reduction of more than 69 % for patients during pacemaker and ICD implantation while image quality was unaffected.
Influence of Slippery Pacemaker Leads on Lead-Induced Venous Occlusion
NASA Astrophysics Data System (ADS)
Yang, Weiguang; Bhatia, Sagar; Obenauf, Dayna; Resse, Max; Esmaily-Moghadam, Mahdi; Feinstein, Jeffrey; Pak, On Shun
2016-11-01
The use of medical devices such as pacemakers and implantable cardiac defibrillators have become commonplace to treat arrhythmias. Pacing leads with electrodes are used to send electrical pulses to the heart to treat either abnormally slow heart rates, or abnormal rhythms. Lead induced vessel occlusion, which is commonly seen after placement of pacemaker or ICD leads, may result in lead malfunction and/or SVC syndrome, and makes lead extraction difficult. The association between the anatomic locations at risk for thrombosis and regions of venous stasis have been reported previously. The computational studies reveal obvious flow stasis in the proximity of the leads, due to the no-slip boundary condition imposed on the lead surface. With the advent of recent technologies capable of creating slippery surfaces that can repel complex fluids including blood, we explore computationally how local flow structures may be altered in the regions around the leads when the no-slip boundary condition on the lead surface is relaxed using various slip lengths. The findings evaluate the possibility of mitigating risks of lead-induced thrombosis and occlusion by implementing novel surface conditions (i.e. theoretical coatings) on the leads.
Wide QRS tachycardia: what is the rhythm?
Rosman, Jonathan; Tawil, Joseph; Hanon, Sam; Schweitzer, Paul
2006-10-01
We report a case of an elderly man who presented to the emergency room complaining of palpitations. Electrocardiogram revealed wide QRS tachycardia with a narrow beat within the tachycardia. Most commonly, a narrow complex beat during a wide complex tachycardia suggests a capture or fusion beat in the setting of ventricular tachycardia. However, there are situations where supraventricular tachycardia can also manifest this way. In our patient a pacemaker interrogation clarified the diagnosis.
Zhu, Tie-Yuan; Wang, Jian-Gang; Meng, Xu
2015-01-01
A best evidence topic in adult valvular surgery was written according to a structured protocol. The question addressed was 'Does concomitant tricuspid annuloplasty increase the perioperative mortality and morbidity when correcting left-sided valve disease?' A total of 561 papers were found using the reported search, of which 12 presented the best evidence to answer the clinical question. The authors, country, journal, date of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Among these 12 papers, there were nine retrospective studies, two cohort studies and one randomized controlled trial (RCT). Overall, additional tricuspid valve (TV) repair takes more time during operations, particularly with a ring annuloplasty method. The mean aortic cross-clamping times were 57-83 min without associated tricuspid repair and 62-100 min with, and cardiopulmonary bypass times without and with repair were 82-124 and 90-174 min, respectively. A study of 624 patients who had undergone isolated mitral valve (MV) surgery and MV surgery plus TV repair showed more female and atrial fibrillation patients in the tricuspid valve plasty (TVP) group, but no increase in the 30-day mortality was found. One RCT, presenting similar patient baseline characteristics, also found no difference in the hospital mortality rates between the TVP group and the non-TVP group. Another 10 studies also demonstrated no statistically significant differences in perioperative mortality. In a cohort study of 311 patients undergoing MV repair with or without tricuspid annuloplasty, postoperative complications, such as bleeding, stroke, pacemaker, haemofiltration and myocardial infarction, all showed no statistically significant differences in the two groups. One study retrospectively analysed a large number of patients undergoing either isolated left-sided valve surgery or a concomitant TV repair, and there were no statistically significant differences regarding major complications (bleeding, pacemaker, respiratory insufficiency, and renal failure). Moreover, another three studies also found no statistically significant differences in terms of bleeding, pacemaker, wound infection, neurological deficit, pericardial effusion, low cardiac output syndrome and dialysis. In conclusion, there is good evidence to support that tricuspid annuloplasty is a low-risk procedure and concomitant TV repair does not significantly increase the perioperative mortality and morbidity when correcting left-sided valve disease. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Tiikkaja, Maria; Aro, Aapo L; Alanko, Tommi; Lindholm, Harri; Sistonen, Heli; Hartikainen, Juha E K; Toivonen, Lauri; Juutilainen, Jukka; Hietanen, Maila
2013-03-01
Electromagnetic interference (EMI) can pose a danger to workers with pacemakers and implantable cardioverter-defibrillators (ICDs). At some workplaces electromagnetic fields are high enough to potentially inflict EMI. The purpose of this in vivo study was to evaluate the susceptibility of pacemakers and ICDs to external electromagnetic fields. Eleven volunteers with a pacemaker and 13 with an ICD were exposed to sine, pulse, ramp, and square waveform magnetic fields with frequencies of 2-200 Hz using Helmholtz coil. The magnetic field flux densities varied to 300 µT. We also tested the occurrence of EMI from an electronic article surveillance (EAS) gate, an induction cooktop, and a metal inert gas (MIG) welding machine. All pacemakers were tested with bipolar settings and three of them also with unipolar sensing configurations. None of the bipolar pacemakers or ICDs tested experienced interference in any of the exposure situations. The three pacemakers with unipolar settings were affected by the highest fields of the Helmholtz coil, and one of them also by the EAS gate and the welding cable. The induction cooktop did not interfere with any of the unipolarly programmed pacemakers. Magnetic fields with intensities as high as those used in this study are rare even in industrial working environments. In most cases, employees can return to work after implantation of a bipolar pacemaker or an ICD, after an appropriate risk assessment. Pacemakers programmed to unipolar configurations can cause danger to their users in environments with high electromagnetic fields, and should be avoided, if possible.
Twenty-four hour Holter monitoring in finishing cattle housed outdoors.
Frese, D A; Thomason, J D; Reinhardt, C; Bartle, S; Rethorst, D; Loneragan, G H; Thomson, D
2017-04-01
Atrial premature complexes have been reported to be the most common arrhythmia in cattle and is suspected to be secondary to systemic disease, especially gastrointestinal disease. In order to properly identify pathologic arrhythmia in cattle, the normal rhythm and arrhythmia prevalence should be defined. The objective of this study was to determine the normal heart rate, rhythm, number of ventricular premature complexes (VPCs), and atrial premature complexes (APCs) in unrestrained Angus steers. Twenty-seven client owned steers with unremarkable physical examinations and serum biochemical analyses were used. Twenty-four hour Holter monitors, attached by a custom-made harness, were retrospectively evaluated. Three lead electrocardiographic registrations of good quality and normal sinus rhythm were obtained from all steers in the study. The mean heart rate was 66.8 bpm ± 16.4 bpm. Ventricular premature complexes were rare (noted in 14.8% of steers), and APCs were common (noted in 85% of the steers). Simple second degree AV block was observed in 18.5% of the steers. In summary, healthy steers have rare single VPCs, although it is possible for an individual animal to have apparent more frequent VPCs. Mean heart rate varies with a diurnal pattern similar to other species. Atrial premature complexes are the most prevalent abnormality observed in feedlot steers. Copyright © 2016 Elsevier B.V. All rights reserved.
Sehar, Nandini; Mears, Jennifer; Bisco, Susan; Patel, Sandeep; Lachman, Nirusha; Asirvatham, Samuel J
2010-01-01
After initial documentation of excellent efficacy with radiofrequency ablation, this procedure is being performed increasingly in more complex situations and for more difficult arrhythmia. In these circumstances, an accurate knowledge of the anatomic basis for the ablation procedure will help maintain this efficacy and improve safety. In this review, we discuss the relevant anatomy for electrophysiology interventions for typical right atrial flutter, atrial fibrillation, and outflow tract ventricular tachycardia. In the pediatric population, maintaining safety is a greater challenge, and here again, knowing the neighboring and regional anatomy of the arrhythmogenic substrate for these arrhythmias may go a long way in preventing complications. PMID:20811537
The retrospectroscope-the invention of the rechargeable cardiac pacemaker: vignette #9.
Fischell, R E
1990-01-01
The idea for a rechargeable cardiac pacemaker came to the author in the late 1960s after reading an advertisement stating that a company's batteries were so good they would last two years in a heart pacemaker. This meant that pacemaker patients would have to undergo surgery for their replacement frequently. Having worked on the development of hermetically sealed, nickel-cadmium batteries that could function for a decade or longer in an orbiting spacecraft, the author constructed the first prototype of a rechargeable cardiac pacemaker around 1968 to show cardiologists at Johns Hopkins Hospital that a pacemaker of indefinitely long life and much smaller size and weight could be built readily. The subsequent development and marketing of the device, which came on the market in 1973, is recounted.
Lee, Jung Hee; Kim, Tae Ho; Kim, Wook Sung
2015-04-01
Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.
The effects of nuclear magnetic resonance on patients with cardiac pacemakers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pavlicek, W.; Geisinger, M.; Castle, L.
1983-04-01
The effect of nuclear magnetic resonance (NMR) imaging on six representative cardiac pacemakers was studied. The results indicate that the threshold for initiating the asynchronous mode of a pacemaker is 17 gauss. Radiofrequency levels are present in an NMR unit and may confuse or possibly inhibit demand pacemakers, although sensing circuitry is normally provided with electromagnetic interference discrimination. Time-varying magnetic fields can generate pulse amplitudes and frequencies to mimic cardiac activity. A serious limitation in the possibility of imaging a patient with a pacemaker would be the alteration of normal pulsing parameters due to time-varying magnetic fields.
21 CFR Appendix B to Subpart B of... - Scope of Product Coverage
Code of Federal Regulations, 2013 CFR
2013-04-01
... Portable air compressor 2 Cardiovascular Panel Cardiovascular Diagnostic 870.1425 Programmable diagnostic... Pacemaker & Accessories 870.1750 External programmable pacemaker pulse generator 2 870.3630 Pacemaker...
21 CFR Appendix B to Subpart B of... - Scope of Product Coverage
Code of Federal Regulations, 2014 CFR
2014-04-01
... Portable air compressor 2 Cardiovascular Panel Cardiovascular Diagnostic 870.1425 Programmable diagnostic... Pacemaker & Accessories 870.1750 External programmable pacemaker pulse generator 2 870.3630 Pacemaker...
21 CFR Appendix B to Subpart B of... - Scope of Product Coverage
Code of Federal Regulations, 2012 CFR
2012-04-01
... Portable air compressor 2 Cardiovascular Panel Cardiovascular Diagnostic 870.1425 Programmable diagnostic... Pacemaker & Accessories 870.1750 External programmable pacemaker pulse generator 2 870.3630 Pacemaker...
... with recurrent arrhythmias, medical devices such as a pacemaker and implantable cardioverter defibrillator (ICD) can help by ... with an ICD Questions to ask your doctor Pacemakers Learn what an artificial pacemaker is, how it ...
... please enable JavaScript. A pacemaker is a small, battery-operated device. This device senses when your heart ... pacemakers have 2 parts: The generator contains the battery and the information to control the heartbeat. The ...
A pacemaker is a small, battery-operated electronic device which is inserted under the skin to help the heart beat regularly and at an appropriate rate. The pacemaker has leads that travel through a large vein ...
The usefulness of a stretch-polyester pouch to encase implanted pacemakers and defibrillators.
Parsonnet, V; Bernstein, A D; Neglia, D; Omar, A
1994-12-01
This study was undertaken to assess the effects of enclosing permanent pacemaker and ICD pulse generators in a stretch-polyester pouch prior to implantation. Follow-up of 223 patients with oversized pacemakers and with ICDs and 344 with standard-sized pacemaker pulse generators showed that the pouch was effective in decreasing the frequency of pulse generator migration and extrusion.
Yaniv, Yael; Ahmet, Ismayil; Tsutsui, Kenta; Behar, Joachim; Moen, Jack M; Okamoto, Yosuke; Guiriba, Toni-Rose; Liu, Jie; Bychkov, Rostislav; Lakatta, Edward G
2016-08-01
We aimed to determine how age-associated changes in mechanisms extrinsic and intrinsic to pacemaker cells relate to basal beating interval variability (BIV) reduction in vivo. Beating intervals (BIs) were measured in aged (23-25 months) and adult (3-4 months) C57BL/6 male mice (i) via ECG in vivo during light anesthesia in the basal state, or in the presence of 0.5 mg mL(-1) atropine + 1 mg mL(-1) propranolol (in vivo intrinsic conditions), and (ii) via a surface electrogram, in intact isolated pacemaker tissue. BIV was quantified in both time and frequency domains using linear and nonlinear indices. Although the average basal BI did not significantly change with age under intrinsic conditions in vivo and in the intact isolated pacemaker tissue, the average BI was prolonged in advanced age. In vivo basal BIV indices were found to be reduced with age, but this reduction diminished in the intrinsic state. However, in pacemaker tissue BIV indices increased in advanced age vs. adults. In the isolated pacemaker tissue, the sensitivity of the average BI and BIV in response to autonomic receptor stimulation or activation of mechanisms intrinsic to pacemaker cells by broad-spectrum phosphodiesterase inhibition declined in advanced age. Thus, changes in mechanisms intrinsic to pacemaker cells increase the average BIs and BIV in the mice of advanced age. Autonomic neural input to pacemaker tissue compensates for failure of molecular intrinsic mechanisms to preserve average BI. But this compensation reduces the BIV due to both the imbalance of autonomic neural input to the pacemaker cells and altered pacemaker cell responses to neural input. © 2016 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.
Cheong, Hyeonsook; Paudyal, Dilli Parasad; Jun, Jae Yeoul; Yeum, Cheol Ho; Yoon, Pyung Jin; Park, Chan Guk; Kim, Man Yoo; So, Insuk; Kim, Ki Whan; Choi, Seok
2005-10-31
Extracts of pine needles (Pinus densiflora Sieb. et Zucc.) have diverse physiological and pharmacological actions. In this study we show that pine needle extract alters pacemaker currents in interstitial cells of Cajal (ICC) by modulating ATP-sensitive K+ channels and that this effect is mediated by prostaglandins. In whole cell patches at 30 degrees , ICC generated spontaneous pacemaker potentials in the current clamp mode (I = 0), and inward currents (pacemaker currents) in the voltage clamp mode at a holding potential of -70 mV. Pine needle extract hyperpolarized the membrane potential, and in voltage clamp mode decreased both the frequency and amplitude of the pacemaker currents, and increased the resting currents in the outward direction. It also inhibited the pacemaker currents in a dose-dependent manner. Because the effects of pine needle extract on pacemaker currents were the same as those of pinacidil (an ATP-sensitive K+ channel opener) we tested the effect of glibenclamide (an ATP-sensitive K+ channels blocker) on ICC exposed to pine needle extract. The effects of pine needle extract on pacemaker currents were blocked by glibenclamide. To see whether production of prostaglandins (PGs) is involved in the inhibitory effect of pine needle extract on pacemaker currents, we tested the effects of naproxen, a non-selective cyclooxygenase (COX-1 and COX-2) inhibitor, and AH6809, a prostaglandin EP1 and EP2 receptor antagonist. Naproxen and AH6809 blocked the inhibitory effects of pine needle extract on ICC. These results indicate that pine needle extract inhibits the pacemaker currents of ICC by activating ATP-sensitive K+ channels via the production of PGs.
Larsen, P D; Kerr, A J; Hood, M; Harding, S A; Hooks, D; Heaven, D; Lever, N A; Sinclair, S; Boddington, D; Tang, E W; Swampillai, J; Stiles, M K
2017-03-01
The New Zealand Cardiac Implanted Device Registry (Device) has recently been developed under the auspices of the New Zealand Branch of the Cardiac Society of Australia and New Zealand. This study describes the initial Device registry cohort of patients receiving a new pacemaker, their indications for pacing and their perioperative complications. The Device Registry was used to audit patients receiving a first pacemaker between 1 st January 2014 and 1 st June 2015. We examined 1611 patients undergoing first pacemaker implantation. Patients were predominantly male (59%), and had a median age of 70 years. The most common symptom for pacemaker implantation was syncope (39%), followed by dizziness (30%) and dyspnoea (12%). The most common aetiology for a pacemaker was a conduction tissue disorder (35%), followed by sinus node dysfunction (22%). Atrioventricular (AV) block was the most common ECG abnormality, present in 44%. Dual chamber pacemakers were most common (62%), followed by single chamber ventricular pacemakers (34%), and cardiac resynchronisation therapy - pacemakers (CRT-P) (2%). Complications within 24hours of the implant procedure were reported in 64 patients (3.9%), none of which were fatal. The most common complication was the need for reoperation to manipulate a lead, occurring in 23 patients (1.4%). This is the first description of data entered into the Device registry. Patients receiving a pacemaker were younger than in European registries, and there was a low use of CRT-P devices compared to international rates. Complications rates were low and compare favourably to available international data. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Kolek, Matthew J; Edwards, Todd L; Muhammad, Raafia; Balouch, Adnan; Shoemaker, M Benjamin; Blair, Marcia A; Kor, Kaylen C; Takahashi, Atsushi; Kubo, Michiaki; Roden, Dan M; Tanaka, Toshihiro; Darbar, Dawood
2014-08-15
For many patients with atrial fibrillation, ventricular rate control with atrioventricular (AV) nodal blockers is considered first-line therapy, although response to treatment is highly variable. Using an extreme phenotype of failure of rate control necessitating AV nodal ablation and pacemaker implantation, we conducted a genome-wide association study (GWAS) to identify genomic modulators of rate control therapy. Cases included 95 patients who failed rate control therapy. Controls (n = 190) achieved adequate rate control therapy with ≤2 AV nodal blockers using a conventional clinical definition. Genotyping was performed on the Illumina 610-Quad platform, and results were imputed to the 1000 Genomes reference haplotypes. A total of 554,041 single-nucleotide polymorphisms (SNPs) met criteria for minor allele frequency (>0.01), call rate (>95%), and quality control, and 6,055,224 SNPs were available after imputation. No SNP reached the canonical threshold for significance for GWAS of p <5 × 10(-8). Sixty-three SNPs with p <10(-5) at 6 genomic loci were genotyped in a validation cohort of 130 cases and 157 controls. These included 6q24.3 (near SAMD5/SASH1, p = 9.36 × 10(-8)), 4q12 (IGFBP7, p = 1.75 × 10(-7)), 6q22.33 (C6orf174, p = 4.86 × 10(-7)), 3p21.31 (CDCP1, p = 1.18 × 10(-6)), 12p12.1 (SOX5, p = 1.62 × 10(-6)), and 7p11 (LANCL2, p = 6.51 × 10(-6)). However, none of these were significant in the replication cohort or in a meta-analysis of both cohorts. In conclusion, we identified several potentially important genomic modulators of rate control therapy in atrial fibrillation, particularly SOX5, which was previously associated with heart rate at rest and PR interval. However, these failed to reach genome-wide significance. Copyright © 2014 Elsevier Inc. All rights reserved.
Zebrafish heart as a model to study the integrative autonomic control of pacemaker function
Stoyek, Matthew R.; Quinn, T. Alexander; Croll, Roger P.
2016-01-01
The cardiac pacemaker sets the heart's primary rate, with pacemaker discharge controlled by the autonomic nervous system through intracardiac ganglia. A fundamental issue in understanding the relationship between neural activity and cardiac chronotropy is the identification of neuronal populations that control pacemaker cells. To date, most studies of neurocardiac control have been done in mammalian species, where neurons are embedded in and distributed throughout the heart, so they are largely inaccessible for whole-organ, integrative studies. Here, we establish the isolated, innervated zebrafish heart as a novel alternative model for studies of autonomic control of heart rate. Stimulation of individual cardiac vagosympathetic nerve trunks evoked bradycardia (parasympathetic activation) and tachycardia (sympathetic activation). Simultaneous stimulation of both vagosympathetic nerve trunks evoked a summative effect. Effects of nerve stimulation were mimicked by direct application of cholinergic and adrenergic agents. Optical mapping of electrical activity confirmed the sinoatrial region as the site of origin of normal pacemaker activity and identified a secondary pacemaker in the atrioventricular region. Strong vagosympathetic nerve stimulation resulted in a shift in the origin of initial excitation from the sinoatrial pacemaker to the atrioventricular pacemaker. Putative pacemaker cells in the sinoatrial and atrioventricular regions expressed adrenergic β2 and cholinergic muscarinic type 2 receptors. Collectively, we have demonstrated that the zebrafish heart contains the accepted hallmarks of vertebrate cardiac control, establishing this preparation as a viable model for studies of integrative physiological control of cardiac function by intracardiac neurons. PMID:27342878
Maltsev, Alexander V.; Maltsev, Victor A.; Stern, Michael D.
2017-01-01
Intracellular Local Ca releases (LCRs) from sarcoplasmic reticulum (SR) regulate cardiac pacemaker cell function by activation of electrogenic Na/Ca exchanger (NCX) during diastole. Prior studies demonstrated the existence of powerful compensatory mechanisms of LCR regulation via a complex local cross-talk of Ca pump, release and NCX. One major obstacle to study these mechanisms is that LCR exhibit complex Ca release propagation patterns (including merges and separations) that have not been characterized. Here we developed new terminology, classification, and computer algorithms for automatic detection of numerically simulated LCRs and examined LCR regulation by SR Ca pumping rate (Pup) that provides a major contribution to fight-or-flight response. In our simulations the faster SR Ca pumping accelerates action potential-induced Ca transient decay and quickly clears Ca under the cell membrane in diastole, preventing premature releases. Then the SR generates an earlier, more synchronized, and stronger diastolic LCR signal activating an earlier and larger inward NCX current. LCRs at higher Pup exhibit larger amplitudes and faster propagation with more collisions to each other. The LCRs overlap with Ca transient decay, causing an elevation of the average diastolic [Ca] nadir to ~200 nM (at Pup = 24 mM/s). Background Ca (in locations lacking LCRs) quickly decays to resting Ca levels (<100 nM) at high Pup, but remained elevated during slower decay at low Pup. Release propagation is facilitated at higher Pup by a larger LCR amplitude, whereas at low Pup by higher background Ca. While at low Pup LCRs show smaller amplitudes, their larger durations and sizes combined with longer transient decay stabilize integrals of diastolic Ca and NCX current signals. Thus, the local interplay of SR Ca pump and release channels regulates LCRs and Ca transient decay to insure fail-safe pacemaker cell operation within a wide range of rates. PMID:28792496
Jones, David G; Haldar, Shouvik K; Jarman, Julian W E; Johar, Sofian; Hussain, Wajid; Markides, Vias; Wong, Tom
2013-08-01
Ablation of persistent atrial fibrillation can be challenging, often involving not only pulmonary vein isolation (PVI) but also additional linear lesions and ablation of complex fractionated electrograms (CFE). We examined the impact of stepwise ablation on a human model of advanced atrial substrate of persistent atrial fibrillation in heart failure. In 30 patients with persistent atrial fibrillation and left ventricular ejection fraction ≤35%, high-density CFE maps were recorded biatrially at baseline, in the left atrium (LA) after PVI and linear lesions (roof and mitral isthmus), and biatrially after LA CFE ablation. Surface area of CFE (mean cycle length ≤120 ms) remote to PVI and linear lesions, defined as CFE area, was reduced after PVI (18.3±12.03 to 10.2±7.1 cm(2); P<0.001) and again after linear lesions (7.7±6.5 cm(2); P=0.006). Complete mitral isthmus block predicted greater CFE reduction (P=0.02). Right atrial CFE area was reduced by LA ablation, from 25.9±14.1 to 12.9±11.8 cm(2) (P<0.001). Estimated 1-year arrhythmia-free survival was 72% after a single procedure. Incomplete linear lesion block was an independent predictor of arrhythmia recurrence (hazard ratio, 4.69; 95% confidence interval, 1.05-21.06; P=0.04). Remote LA CFE area was progressively reduced following PVI and linear lesions, and LA ablation reduced right atrial CFE area. Reduction of CFE area at sites remote from ablation would suggest either regression of the advanced atrial substrate or that these CFE were functional phenomena. Nevertheless, in an advanced atrial fibrillation substrate, linear lesions after PVI diminished the target area for CFE ablation, and complete lesions resulted in a favorable clinical outcome.
Multiple lentigines, myxoid tumours and endocrine overactivity; four cases of Carney's complex.
Handley, J; Carson, D; Sloan, J; Walsh, M; Thornton, C; Hadden, D; Bingham, E A
1992-04-01
Four patients with Carney's complex, one sporadic and three familial, are described. The sporadic case was a young male with centrofacial lentigines, who developed cyclical Cushing's syndrome secondary to bilateral pigmented nodular adrenocortical disease, two separate left atrial myxomas, and buccal mucosal myxomas. The three familial cases, who all had varying degrees of centrofacial/mucosal lentigines and cutaneous myxoid tumours, were a woman with myxoid mammary fibroadenomatosis and a left atrial myxoma, her daughter who developed a prolactin-secreting pituitary adenoma, and her son who had bilateral large-cell calcified Sertoli cell testicular tumours, and an axillary psammomatous melanotic schwannoma.
Reticulated telangiectatic erythema of the pacemaker.
Martin, Lucy K; Wendschuh, Philip; Wendschuh, Peter
2008-05-01
Reticulated telangiectatic erythema is a rare entity; it has been reported to occur following the placement of implanted cardiac devices and drug delivery systems. Histologically, reticulated telangiectatic erythema of the pacemaker is characterized by slight spongiosis and increased dermal telangiectasias. We describe a patient that developed reticulated telangiectatic nonpruritic patches on the left chest after the placement of a pacemaker. The patient responded favorably to the removal of the pacemaker.
Retrieval of the Leadless Cardiac Pacemaker: A Multicenter Experience.
Reddy, Vivek Y; Miller, Marc A; Knops, Reinoud E; Neuzil, Petr; Defaye, Pascal; Jung, Werner; Doshi, Rahul; Castellani, Mark; Strickberger, Adam; Mead, R Hardwin; Doppalapudi, Harish; Lakkireddy, Dhanunjaya; Bennett, Matthew; Sperzel, Johannes
2016-12-01
Leadless cardiac pacemakers have emerged as a safe and effective alternative to conventional transvenous single-chamber ventricular pacemakers. Herein, we report a multicenter experience on the feasibility and safety of acute retrieval (<6 weeks) and chronic retrieval (>6 weeks) of the leadless cardiac pacemaker in humans. This study included patients enrolled in 3 multicenter trials, who received a leadless cardiac pacemaker implant and who subsequently underwent a device removal attempt. The overall leadless pacemaker retrieval success rate was 94%: for patients whose leadless cardiac pacemaker had been implanted for <6 weeks (acute retrieval cohort), complete retrieval was achieved in 100% (n=5/5); for those implanted for ≥ 6 weeks (chronic retrieval cohort), retrieval was achieved in 91% (n=10/11) of patients. The mean duration of time from implant to retrieval attempt was 346 days (range, 88-1188 days) in the chronic retrieval cohort, and nearly two thirds (n=7; 63%) had been implanted for >6 months before the retrieval attempt. There were no procedure-related adverse events at 30 days post retrieval procedure. This multicenter experience demonstrated the feasibility and safety of retrieving a chronically implanted single-chamber (right ventricle) active fixation leadless pacemaker. URL: https://www.clinicaltrials.gov. Unique identifiers: NCT02051972, NCT02030418, and NCT01700244. © 2016 American Heart Association, Inc.
Rhabdomyosarcoma associated with the lead wire of a pacemaker generator implant.
Thieman Mankin, Kelley M; Dunbar, Mark D; Toplon, David; Ginn, Pamela; Maisenbacher, Herbert W; Risselada, Marije
2014-06-01
An 11-year-old female spayed Labrador Retriever was presented for a draining, painful subcutaneous mass palpated over a previously implanted pacemaker generator. Infection was suspected and the mass was removed surgically. On cut surface, the mass was friable and mottled tan to brown with firm pale tan nodules, surrounding the pacemaker lead wire adjacent to the pacemaker generator. Cytologic interpretation of impression smears was consistent with a sarcoma, and suggestive of a rhabdomyosarcoma due to the presence of strap-like cells. On histopathologic examination, a highly invasive nodular mass surrounded the pacemaker lead, composed of pleomorphic round, spindle and strap cells, and multinucleated giant cells. The population exhibited microscopic invasion into the deep portion of the fibrous capsule surrounding the pacemaker generator. There were tumor emboli within small to medium subcutaneous veins adjacent to the mass. Immunohistochemically, the neoplastic cells stained positive for α-sarcomeric actin and vimentin, and negative for α-smooth muscle actin, consistent with a rhabdomyosarcoma arising at the site of the pacemaker generator. To our knowledge, this is the first report of a rhabdomyosarcoma associated with the lead wire of a pacemaker generator in a dog. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Influence of digital and analogue cellular telephones on implanted pacemakers.
Altamura, G; Toscano, S; Gentilucci, G; Ammirati, F; Castro, A; Pandozi, C; Santini, M
1997-10-01
The aim of this study was to find out whether digital and analogue cellular 'phones affect patients with pacemakers. The study comprised continuous ECG monitoring of 200 pacemaker patients. During the monitoring certain conditions caused by interference created by the telephone were looked for: temporary or prolonged pacemaker inhibition; a shift to asynchronous mode caused by electromagnetic interference; an increase in ventricular pacing in dual chamber pacemakers, up to the programmed upper rate. The Global System for Mobile Communications system interfered with pacing 97 times in 43 patients (21.5%). During tests on Total Access of Communication System telephones, there were 60 cases of pacing interference in 35 patients (17.5%). There were 131 interference episodes during ringing vs 26 during the on/off phase; (P < 0.0001); 106 at maximum sensitivity level vs 51 at the 'base' value; P < 0.0001). Prolonged pacing inhibition (> 4 s) was seen at the pacemaker 'base' sensing value in six patients using the Global system but in only one patient using Total Access. Cellular 'phones may be dangerous for pacemaker patients. However, they can be used safely if patients do not carry the 'phone close to the pacemaker, which is the only place where high risk interference has been observed.
Magnetic electroanatomical mapping for ablation of focal atrial tachycardias.
Marchlinski, F; Callans, D; Gottlieb, C; Rodriguez, E; Coyne, R; Kleinman, D
1998-08-01
Uniform success for ablation of focal atrial tachycardias has been difficult to achieve using standard catheter mapping and ablation techniques. In addition, our understanding of the complex relationship between atrial anatomy, electrophysiology, and surface ECG P wave morphology remains primitive. The magnetic electroanatomical mapping and display system (CARTO) offers an on-line display of electrical activation and/or signal amplitude related to the anatomical location of the recorded sites in the mapped chamber. A window of electrical interest is established based on signals timed from an electrical reference that usually represents a fixed electrogram recording from the coronary sinus or the atrial appendage. This window of electrical interest is established to include atrial activation prior to the onset of the P wave activity associated with the site of origin of a focal atrial tachycardia. Anatomical and electrical landmarks are defined with limited fluoroscopic imaging support and more detailed global chamber and more focal atrial mapping can be performed with minimal fluoroscopic guidance. A three-dimensional color map representing atrial activation or voltage amplitude at the magnetically defined anatomical sites is displayed with on-line data acquisition. This display can be manipulated to facilitate viewing from any angle. Altering the zoom control, triangle fill threshold, clipping plane, or color range can all enhance the display of a more focal area of interest. We documented the feasibility of using this single mapping catheter technique for localizing and ablating focal atrial tachycardias. In a consecutive series of 8 patients with 9 focal atrial tachycardias, the use of the single catheter CARTO mapping system was associated with ablation success in all but one patient who had a left atrial tachycardia localized to the medial aspect of the orifice of the left atrial appendage. Only low power energy delivery was used in this patient because of the unavailability of temperature monitoring in the early version of the Navistar catheter, the location of the arrhythmia, and the history of arrhythmia control with flecainide. No attempt was made to limit fluoroscopy time in our study population. Nevertheless, despite data acquisition from 120-320 anatomically distinct sites during global and more detailed focal atrial mapping, total fluoroscopy exposure was typically < 30 minutes and was as little as 12 minutes. The detailed display capabilities of the CARTO system appear to offer the potential of enhancing our understanding of atrial anatomy, atrial activation, and their relationship to surface ECG P wave morphology during focal atrial tachycardias.
Atrial flutter after surgical maze: incidence, diagnosis, and management.
Dresen, William; Mason, Pamela K
2016-01-01
The prevalence of atrial fibrillation is increasing and surgical ablation is becoming more common, both as a stand-alone procedure and when performed concomitantly with other cardiac surgery. Although surgical ablation is effective, with it unique challenges arise, including iatrogenic macroreentrant tachycardias that are often highly symptomatic and difficult to manage conservatively. Postsurgical ablation, localization of the arrhythmic circuit is difficult to determine using surface ECG alone because of alterations in the atrial myocardium, and multiple different pathways are often present. Most, however, localize to the left atrium, and percutaneous catheter ablation is emerging as an effective treatment modality. Patients with complex postoperative arrhythmias should be referred to a dedicated atrial fibrillation center when possible and symptomatic arrhythmias mapped and ablated. Knowledge of the previously performed surgical lesion set is of vital importance in understanding the mechanism of the arrhythmia and increasing procedural success rates. http://links.lww.com/HCO/A31.
Pacemaker therapy in low-birth-weight infants.
Fuchigami, Tai; Nishioka, Masahiko; Akashige, Toru; Shimabukuro, Atsuya; Nagata, Nobuhiro
2018-02-01
Infants born with complete atrioventricular block (CAVB) and fetal bradycardia are frequently born with low birth weight. Three low-birth-weight CAVB infants underwent temporary pacemaker implantation, followed by permanent single-chamber pacemaker implantation at median body weights of 1.7 and 3.2 kg, respectively. All infants caught up with their growth curves and had >3 years of estimated residual battery life. This two-stage strategy was successful in facilitating permanent pacemaker implantation in low-birth-weight babies. Placement of single-chamber pacemaker on the apex of the left ventricle appears to be associated with longer battery lifespan. © 2018 Wiley Periodicals, Inc.
Effect on pacemakers of airport weapons detectors
Johnson, David L.
1974-01-01
An investigation was carried out using a variety of pacemakers and all the types of weapons detectors in common use in Canada, to determine whether or not such detectors present a hazard to pacemaker bearers. The results indicate that only left-side implants of unipolar sensing pacemakers are likely to be affected, that ventricular fibrillation initiated by interference-induced competitive pacing is the only conceivable hazard, but that the probability of 10−9 for the occurrence of this event is so low that it may be completely disregarded. Physicians may therefore reassure pacemaker bearers of their safety in and around airport weapons detectors. ImagesFIG. 1 PMID:4825148
NASA Technical Reports Server (NTRS)
1990-01-01
Synchrony, developed by St. Jude Medical's Cardiac Rhythm Management Division (formerly known as Pacesetter Systems, Inc.) is an advanced state-of-the-art implantable pacemaker that closely matches the natural rhythm of the heart. The companion element of the Synchrony Pacemaker System is the Programmer Analyzer APS-II which allows a doctor to reprogram and fine tune the pacemaker to each user's special requirements without surgery. The two-way communications capability that allows the physician to instruct and query the pacemaker is accomplished by bidirectional telemetry. APS-II features 28 pacing functions and thousands of programming combinations to accommodate diverse lifestyles. Microprocessor unit also records and stores pertinent patient data up to a year.
Space Derived Health Aids (Cardiac Pacemaker)
NASA Technical Reports Server (NTRS)
1981-01-01
St. Jude Medical's Cardiac Rhythm Management Division's (formerly known as Pacesetter Systems, Inc.) pacer is a rechargeable cardiac pacemaker that eliminates the recurring need for surgery to implant a new battery. The Programalith is an advanced cardiac pacing system which permits a physician to reprogram a patient's implanted pacemaker without surgery. System consists of a pacemaker, together with a physician's console containing the programmer and a data printer. Signals are transmitted by wireless telemetry. Two-way communications, originating from spacecraft electrical power systems technology, allows physician to interrogate the pacemaker as to the status of the heart, then to fine tune the device to best suit the patient's needs.
Pacemakers and Implantable Defibrillators - Multiple Languages
... Multiple Languages → All Health Topics → Pacemakers and Implantable Defibrillators URL of this page: https://medlineplus.gov/languages/ ... List of All Topics All Pacemakers and Implantable Defibrillators - Multiple Languages To use the sharing features on ...
Mainigi, Sumeet K; Chebrolu, Lakshmi Hima Bindu; Romero-Corral, Abel; Mehta, Vinay; Machado, Rodolfo Rozindo; Konecny, Tomas; Pressman, Gregg S
2012-10-01
Cardiac calcification is associated with coronary artery disease, arrhythmias, conduction disease, and adverse cardiac events. Recently, we have described an echocardiographic-based global cardiac calcification scoring system. The objective of this study was to evaluate the severity of cardiac calcification in patients with permanent pacemakers as based on this scoring system. Patients with a pacemaker implanted within the 2-year study period with a previous echocardiogram were identified and underwent blinded global cardiac calcium scoring. These patients were compared to matched control patients without a pacemaker who also underwent calcium scoring. The study group consisted of 49 patients with pacemaker implantation who were compared to 100 matched control patients. The mean calcium score in the pacemaker group was 3.3 ± 2.9 versus 1.8 ± 2.0 (P = 0.006) in the control group. Univariate and multivariate analysis revealed glomerular filtration rate and calcium scoring to be significant predictors of the presence of a pacemaker. Echocardiographic-based calcium scoring correlates with the presence of severe conduction disease requiring a pacemaker. © 2012, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Yu, Haitao; Wang, Jiang; Liu, Chen; Deng, Bin; Wei, Xile
2011-12-01
We study the phenomenon of stochastic resonance on a modular neuronal network consisting of several small-world subnetworks with a subthreshold periodic pacemaker. Numerical results show that the correlation between the pacemaker frequency and the dynamical response of the network is resonantly dependent on the intensity of additive spatiotemporal noise. This effect of pacemaker-driven stochastic resonance of the system depends extensively on the local and the global network structure, such as the intra- and inter-coupling strengths, rewiring probability of individual small-world subnetwork, the number of links between different subnetworks, and the number of subnetworks. All these parameters play a key role in determining the ability of the network to enhance the noise-induced outreach of the localized subthreshold pacemaker, and only they bounded to a rather sharp interval of values warrant the emergence of the pronounced stochastic resonance phenomenon. Considering the rather important role of pacemakers in real-life, the presented results could have important implications for many biological processes that rely on an effective pacemaker for their proper functioning.
Hu, Yu-Feng; Dawkins, James Frederick; Cho, Hee Cheol; Marbán, Eduardo; Cingolani, Eugenio
2016-01-01
Somatic reprogramming by reexpression of the embryonic transcription factor T-box 18 (TBX18) converts cardiomyocytes into pacemaker cells. We hypothesized that this could be a viable therapeutic avenue for pacemaker-dependent patients afflicted with device-related complications, and therefore tested whether adenoviral TBX18 gene transfer could create biological pacemaker activity in vivo in a large-animal model of complete heart block. Biological pacemaker activity, originating from the intramyocardial injection site, was evident in TBX18-transduced animals starting at day 2 and persisted for the duration of the study (14 days) with minimal backup electronic pacemaker use. Relative to controls transduced with a reporter gene, TBX18-transduced animals exhibited enhanced autonomic responses and physiologically superior chronotropic support of physical activity. Induced sinoatrial node cells could be identified by their distinctive morphology at the site of injection in TBX18-transduced animals, but not in controls. No local or systemic safety concerns arose. Thus, minimally invasive TBX18 gene transfer creates physiologically relevant pacemaker activity in complete heart block, providing evidence for therapeutic somatic reprogramming in a clinically relevant disease model. PMID:25031269
Involvement of mitochondrial Na+–Ca2+ exchange in intestinal pacemaking activity
Kim, Byung Joo; Jun, Jae Yeoul; So, Insuk; Kim, Ki Whan
2006-01-01
AIM: Interstitial cells of Cajal (ICCs) are the pacemaker cells that generate slow waves in the gastrointestinal (GI) tract. We have aimed to investigate the involvement of mitochondrial Na+-Ca2+ exchange in intestinal pacemaking activity in cultured interstitial cells of Cajal. METHODS: Enzymatic digestions were used to dissociate ICCs from the small intestine of a mouse. The whole-cell patch-clamp configuration was used to record membrane currents (voltage clamp) and potentials (current clamp) from cultured ICCs. RESULTS: Clonazepam and CGP37157 inhibited the pacemaking activity of ICCs in a dose-dependent manner. Clonazepam from 20 to 60 µmol/L and CGP37157 from 10 to 30 µmol/L effectively inhibited Ca2+ efflux from mitochondria in pacemaking activity of ICCs. The IC50s of clonazepam and CGP37157 were 37.1 and 18.2 µmol/L, respectively. The addition of 20 µmol/L NiCl2 to the internal solution caused a “wax and wane” phenomenon of pacemaking activity of ICCs. CONCLUSION: These results suggest that mitochondrial Na+-Ca2+ exchange has an important role in intestinal pacemaking activity. PMID:16521198
Pelissero, Elisa; Giuggia, Marco; Todaro, Maria Chiara; Trapani, Giuseppe; Giordano, Benedetta; Senatore, Gaetano
2017-12-01
We evaluated long-term safety and efficacy of concomitant left atrial appendage (LAA) closure and atrial fibrillation (AF) ablation. From February 2013 to June 2017, all patients referred for AF ablation and LAA closure (group 1) were enrolled in the study and compared with a matched control group undergoing AF ablation only (group 2). Pulmonary vein isolation was achieved in all cases with radiofrequency or cryoballoon. LAA was occluded with Watchman or Amplatzer Cardiac Plug or Amulet (ACP) devices. All patients were treated with oral anticoagulation therapy for at least 3 months after the procedure ("blanking period"), and then switched to dual antiplatelet therapy with aspirin and clopidogrel for other 3 months, and then to single antiplatelet therapy with aspirin in case of LAA closure, while group 2 was treated with long-term oral anticoagulation therapy according to CHA2DS2-VASc score. Follow-up was performed with transesophageal echocardiography and clinical visit at 3, 6 and 12 months after the procedure. AF burden was evaluated by loop recorder or pacemaker interrogation in all patients. Overall, 42 patients were enrolled, 21 in each group. Mean age was 66.86 ± 10.35 years in group 1 vs 68.42 ± 10.61 in group 2 (p=NS); mean CHA2DS2-VASc score was 2.8 ± 1.22 in group 1 vs 2.01 ± 0.93 in group 2 (p=NS), mean HAS-BLED score was 3.2 ± 0.83 in group 1 vs 3.1 ± 0.95 in group 2 (p=NS). Persistent AF was present in 80% of patients in group 1 and in 85% in group 2. LAA closure was successful in all cases (14 Watchman, 7 ACP devices). Procedural and fluoroscopy times were shorter in group 2 (68 ± 17 vs 52 ± 15 min, p <0.05; 23 ± 5 vs 18 ± 3 min, p <0.05, respectively). No procedural complications were observed in group 2, while in group 1 one case of self-terminating pericardial effusion and one arteriovenous fistula were observed. At a mean follow-up of 14.93 ± 10.05 months, complete seal of LAA was documented in all patients, with neither dislocations nor thromboembolic events. Similarly, no long-term complications were observed in group 2. Maintenance of sinus rhythm was overlapping, with an AF relapse rate of 36% in group 1 vs 38% in group 2 (p=NS). Combined LAA percutaneous closure and AF ablation appears to be feasible in high-risk patients.
Segundo, J P; Vibert, J F; Stiber, M
1998-11-01
Codings involving spike trains at synapses with inhibitory postsynaptic potentials on pacemakers were examined in crayfish stretch receptor organs by modulating presynaptic instantaneous rates periodically (triangles or sines; frequencies, slopes and depths under, respectively, 5.0 Hz, 40.0/s/s and 25.0/s). Timings were described by interspike and cross-intervals ("phases"); patterns (dispersions, sequences) and forms (timing classes) were identified using pooled graphs (instant along the cycle when a spike occurs vs preceding interval) and return maps (plots of successive intervals). A remarkable heterogeneity of postsynaptic intervals and phases characterizes each modulation. All cycles separate into the same portions: each contains a particular form and switches abruptly to the next. Forms differ in irregularity and predictability: they are (see text) "p:q alternations", "intermittent", "phase walk-throughs", "messy erratic" and "messy stammering". Postsynaptic cycles are asymmetric (hysteresis). This contrasts with the presynaptic homogeneity, smoothness and symmetry. All control parameters are, individually and jointly, strongly influential. Presynaptic slopes, say, act through a postsynaptic sensitivity to their magnitude and sign; when increasing, hysteresis augments and forms change or disappear. Appropriate noise attenuates between-train contrasts, providing modulations are under 0.5 Hz. Postsynaptic natural intervals impose critical time bases, separating presynaptic intervals (around, above or below them) with dissimilar consequences. Coding rules are numerous and have restricted domains; generalizations are misleading. Modulation-driven forms are trendy pacemaker-driven forms. However, dissimilarities, slight when patterns are almost pacemaker, increase as inhibition departs from pacemaker and incorporate unpredictable features. Physiological significance-(1) Pacemaker-driven forms, simple and ubiquitous, appear to be elementary building blocks of synaptic codings, present always but in each case distorted typically. (2) Synapses are prototype: similar behaviours should be widespread, and networks simulations benefit by nonlinear units generating all forms. (3) Relevant to periodic functions are that few variables need be involved in form selection, that distortions are susceptible to noise levels and, if periods are heterogeneous, that simple input cycles impose heterogeneous outputs. (4) Slow Na inactivations are necessary for obtaining complex forms and hysteresis. Formal significance--(1) Pacemaker-driven forms and presumably their modulation-driven counterparts, pertain to universal periodic, intermittent, quasiperiodic and chaotic categories whose formal properties carry physiological connotations. (2) Only relatively elaborate, nonlinear geometric models show all forms; simpler ones, show only alternations and walk-throughs. (3) Bifurcations resemble those of simple maps that can provide useful guidelines. (4) Heterogeneity poses the unanswered question of whether or not the entire cycle and all portions have the same behaviours: therefore, whether trajectories are continuous or have discontinuities and/or singular points.
1978 Pacemaker Newspaper Awards: What Makes a Pacemaker?
ERIC Educational Resources Information Center
Brasler, Wayne
1979-01-01
Lists the nine high school and college newspapers, and the one newsmagazine, that won Pacemaker Awards in 1978; discusses characteristics that make each of them outstanding, and provides reproductions of a front page from each publication. (GT)
Stem cells as biological heart pacemakers.
Gepstein, Lior
2005-12-01
Abnormalities in the pacemaker function of the heart or in cardiac impulse conduction may result in the appearance of a slow heart rate, traditionally requiring the implantation of a permanent electronic pacemaker. In recent years, a number of experimental approaches have been developed in an attempt to generate biological alternatives to implantable electronic devices. These strategies include, initially, a number of gene therapy approaches (aiming to manipulate the expression of ionic currents or their modulators and thereby convert quiescent cardiomyocytes into pacemaking cells) and, more recently, the use of cell therapy and tissue engineering. The latter approach explored the possibility of grafting pacemaking cells, either derived directly during the differentiation of human embryonic stem cells or engineered from mesenchymal stem cells, into the myocardium. This review will describe each of these approaches, focusing mainly on the stem cell strategies, their possible advantages and shortcomings, as well as the avenues required to make biological pacemaking a clinical reality.
Case of pacemaker pocket infection caused by Finegoldia magna.
Hosseini Dehkordi, Seyed Hamed; Osorio, Georgina
2017-10-01
Finegoldia magna (formerly called Peptostreptococcus magnus) is a Gram-positive anaerobic coccus which is increasingly recognized as an opportunistic pathogen. We present a case of F. magna associated non-valvular cardiovascular device-related infection in an 83 year-old male who received a permanent pacemaker for sick sinus syndrome seven weeks prior to his presentation. Five weeks after the implantation, the pacemaker and leads were explanted because of clinical evidence of pacemaker pocket infection. He was initially treated with sulfamethoxazole-trimethoprim based on the Gram stain results from the removed pacemaker. However, two weeks later, he was readmitted with sepsis and was successfully treated with ampicillin-sulbactam. Culture results from the pacemaker and pocket as well as blood cultures grew F. magna. Clinicians should be aware of the possibility of F. magna infection when initial gram stain results show "gram positive cocci". Copyright © 2017 Elsevier Ltd. All rights reserved.
Butrous, G S; Meldrum, S J; Barton, D G; Male, J C; Bonnell, J A; Camm, A J
1982-05-01
The effect on an implanted, multiprogrammable pacemaker of power-frequency (50 Hz) electric fields up to an intensity (unperturbed value measured at 1.7 m) of 20 kV/m were assessed in ten paced patients. Radiotelemetric monitoring of the electrocardiogram allowed supervision of the electrocardiogram throughout exposure to the alternating electric field. Displacement body currents of up to 300μA were achieved depending on the position and height of the patient. None of the pacemakers was inhibited, triggered or reverted to fixed rate operation during the exposure. The programmable functions, programmability or output characteristics were not affected. Small changes in cardiac rate and rhythm elicited the correct pacemaker responses. Unlike earlier models of pacemaker, this modern implanted pacemaker, which represents `the state of the art', is not affected by 50 Hz electric fields likely to be encountered when standing underneath power lines.
Ugarte, Juan P; Orozco-Duque, Andrés; Tobón, Catalina; Kremen, Vaclav; Novak, Daniel; Saiz, Javier; Oesterlein, Tobias; Schmitt, Clauss; Luik, Armin; Bustamante, John
2014-01-01
There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-linear dynamic measures, such as approximate entropy, and that this tool could be used for locating the rotor tip. The aim of this work has been to determine the relationship between approximate entropy and fractionated electrograms, and to develop a new tool for rotor mapping based on fractionation levels. Two episodes of chronic atrial fibrillation were simulated in a 3D human atrial model, in which rotors were observed. Dynamic approximate entropy maps were calculated using unipolar electrogram signals generated over the whole surface of the 3D atrial model. In addition, we optimized the approximate entropy calculation using two real multi-center databases of fractionated electrogram signals, labeled in 4 levels of fractionation. We found that the values of approximate entropy and the levels of fractionation are positively correlated. This allows the dynamic approximate entropy maps to localize the tips from stable and meandering rotors. Furthermore, we assessed the optimized approximate entropy using bipolar electrograms generated over a vicinity enclosing a rotor, achieving rotor detection. Our results suggest that high approximate entropy values are able to detect a high level of fractionation and to locate rotor tips in simulated atrial fibrillation episodes. We suggest that dynamic approximate entropy maps could become a tool for atrial fibrillation rotor mapping.
Epidemiology of central sleep apnoea in heart failure.
Naughton, Matthew T
2016-03-01
Central sleep apnoea occurs in about a third of patients with reduced systolic heart failure and is a marker of increased mortality. Such patients usually are older males with advanced heart failure (i.e., high pulmonary wedge pressure), often in atrial fibrillation, with evidence of hyperventilation (i.e., low PaCO2) in the absence of hypoxemia. Characteristically, ventilation waxes and wanes in a sinusoidal pattern, with mild hypoxemia, occurring in the lighter levels of sleep usually when supine. Snoring may also occur in central sleep apnoea, often at the peak of hyperventilation, sometimes contributing to the confusion or overlap with obstructive sleep apnoea. Central sleep apnoea is associated with orthopnoea, paroxysmal nocturnal dyspnoea and an oscillatory respiratory pattern with an incremental cardiopulmonary exercise study. Importantly, heart failure therapies (e.g., afterload reduction, diuresis, pacemakers, transplantation) attenuate central sleep apnoea. Night to night variability in severity of central sleep apnoea may occur with changes in patients' posture during sleep (less severe when sleeping on-side or upright). Crown Copyright © 2016. Published by Elsevier Ireland Ltd. All rights reserved.
Gunther-Harrington, Catherine T; Michel, Adam O; Stern, Joshua A
2015-12-01
Placement of an endocardial VDD pacing lead in small dogs (<12 kg) may necessitate a redundant lead remaining looped in the right atrium for appropriate sensing and pacing. This report documented acquired tricuspid valve stenosis in two small dogs between 8 months and 4 years after VDD pacemaker placement for third-degree atrioventricular block. Echocardiography and Doppler echocardiography identified elevated transtricuspid flow velocities, prolonged pressure half-times, decreased valve leaflet excursions, and tricuspid regurgitation in both cases. Both cases were euthanized secondary to this pacing complication. Necropsy was performed in one case and confirmed adherence between the redundant lead loop, atrial and valve tissue. While VDD pacing in dogs has proven hemodynamic benefits, these benefits have not been demonstrated in terms of survival benefit or clinical signs. The requirement of redundant lead placement in small dogs for appropriate VDD lead function creates potential deleterious effects that should be weighed against the possible clinical value of VDD pacing in these patients. Copyright © 2015 Elsevier B.V. All rights reserved.
A Single Center Study of 1,179 Heart Transplant Patients-Factors Affecting Pacemaker Implantation.
Wellmann, Petra; Herrmann, Florian Ernst Martin; Hagl, Christian; Juchem, Gerd
2017-03-01
After around 10% of heart transplant patients require pacemaker implantation. The bradyarrhythmias causing pacemaker requirement include sinus node dysfunction (SND) and atrioventricular block (AVB). This study sought to define clinical predictors for pacemaker requirement as well as identify differences in the patient groups developing SND and AVB. Our operative database was used to collect retrospective recipient, donor, and operative data of all patients receiving orthotopic heart transplants between 1981 and 2016. In the 35-year period 1,179 transplants were performed (mean recipient age 45.5 ± 0.5 years, 20.4% female, 90.6% biatrial technique) with bradyarrhythmias requiring pacemaker implantation developing in 135 patients (11.5%). Independent risk factors were prolonged operative time 340 minutes versus 313 minutes (P = 0.027) and a biatrial anastomosis (P = 0.036). Ischemia time, cardiopulmonary bypass time, aortic cross clamp time, and reperfusion time all had no significant effect on pacemaker implantation rates. Similarly, whether the transplant was a reoperation, a retransplant, or performed after primary assist implantation had no effects on pacemaker implantation rates. There was no survival difference between the paced and nonpaced groups. The donor age was higher in the patients who developed AVB as the indication for pacemaker implantation (43 vs 34 years, P = 0.031). Patients with AVB had longer aortic cross clamp times and developed the arrhythmia later than those who developed SND. Use of the bicaval instead of the biatrial technique and shortened operative times should reduce pacemaker requirement after heart transplantation. Survival is not affected by this complication. © 2017 Wiley Periodicals, Inc.
Lin, Yun; Melby, Daniel P; Krishnan, Balaji; Adabag, Selcuk; Tholakanahalli, Venkatakrishna; Li, Jian-Ming
2017-08-01
The aim of this study is to investigate the frequency of electrosurgery-related pacemaker malfunction. A retrospective study was conducted to investigate electrosurgery-related pacemaker malfunction in consecutive patients undergoing pulse generator (PG) replacement or upgrade from two large hospitals in Minneapolis, MN between January 2011 and January 2014. The occurrence of this pacemaker malfunction was then studied by using MAUDE database for all four major device vendors. A total of 1398 consecutive patients from 2 large tertiary referral centers in Minneapolis, MN undergoing PG replacement or upgrade surgery were retrospectively studied. Four patients (0.3% of all patients), all with pacemakers from St Jude Medical (2.8%, 4 of 142) had output failure or inappropriately low pacing rate below 30 bpm during electrosurgery, despite being programmed in an asynchronous mode. During the same period, 1174 cases of pacemaker malfunctions were reported on the same models in MAUDE database, 37 of which (3.2%) were electrosurgery-related. Twenty-four cases (65%) had output failure or inappropriate low pacing rate. The distribution of adverse events was loss of pacing (59.5%), reversion to backup pacing (32.4%), inappropriate low pacing rate (5.4%), and ventricular fibrillation (2.7%). The majority of these (78.5%) occurred during PG replacement at ERI or upgrade surgery. No electrosurgery-related malfunction was found in MAUDE database on 862 pacemaker malfunction cases during the same period from other vendors. Electrosurgery during PG replacement or upgrade surgery can trigger output failure or inappropriate low pacing rate in certain models of modern pacemakers. Cautions should be taken for pacemaker-dependent patients.
2013-01-01
Background To test the hypothesis that the oral cavity is a potential source for implantable pacemaker and cardioverter defibrillators infections, the bacterial diversity on explanted rhythm heart management devices was investigated and compared to the oral microbiome. Methods A metagenomic approach was used to analyze the bacterial diversity on the surfaces of non-infected and infected pacemakers. The DNA from surfaces swaps of 24 non-infected and 23 infected pacemaker were isolated and subjected to bacterial-specific DNA amplification, single strand conformation polymorphism- (SSCP) and sequencing analysis. Species-specific primer sets were used to analyze for any correlation between bacterial diversity on pacemakers and in the oral cavity. Results DNA of bacterial origin was detected in 21 cases on infected pacemakers and assigned to the bacterial phylotypes Staphylococcus epidermidis, Propionibacterium acnes, Staphylococcus aureus, Staphylococcus schleiferi and Stapyhlococcus. In 17 cases bacterial DNA was found on pacemakers with no clinical signs of infections. On the basis of the obtained sequence data, the phylotypes Propionibacterium acnes, Staphylococcus and an uncultured bacterium were identified. Propionibacterium acnes and Staphylococcus epidermidis were the only bacteria detected in pacemeaker (n = 25) and oral samples (n = 11). Conclusions The frequency of the coincidental detection of bacteria on infected devices and in the oral cavity is low and the detected bacteria are highly abundant colonizers of non-oral human niches. The transmission of oral bacteria to the lead or device of implantable pacemaker or cardioverter defibrillators is unlikely relevant for the pathogenesis of pacemaker or cardioverter defibrillators infections. PMID:23575037
Is pacemaker therapy the right key to patients with vasovagal syncope?
Radovanović, Nikola N; Kirćanski, Bratislav; Raspopović, Srdjan; Pavlović, Siniša U; Jovanović, Velibor; Milašinović, Goran
2016-01-01
Vasovagal syncope is the most common type of reflex syncope. Efficacy of cardiac pacing in this indication has not been the subject of many studies and pacemaker therapy in patients with vasovagal syncope is still controversial. This study aimed to assess the efficacy and safety of pacing therapy in treatment of patients with vasovagal syncope, to determine contribution of new therapeutic models in increasing its success, and to identify risk factors associated with a higher rate of symptoms after pacemaker implantation. A retrospective study included 30 patients with pacemaker implanted due to vasovagal syncope in the Pacemaker Center, Clinical Center of Serbia, between November 2003 and June 2014. Head-up tilt test was performed to diagnose vasovagal syncope. Patients with cardioinhibitory and mixed type of disease were enrolled in the study. Mean age was 48.1 ± 11.1 years and 18 (60%) patients were men. Mean follow-up period was 5.9 ± 3.0 years. Primarily, implantable loop recorder was implanted in 10 (33.3%) patients. Twenty (66.7%) patients presented cardioinhibitory and 10 (33.3%) mixed type of vasovagal syncope. After pacemaker implantation, 11 (36.7%) patients had syncope. In multiple logistic regression analysis we showed that syncope is statistically more likely to occur after pacemaker implantation in patients with mixed type of vasovagal syncope (p = 0.018). There were two (6.7%) perioperative surgical complications. Pacemaker therapy is a safe treatment for patients with vasovagal syncope, whose efficacy can be improved by strict selection of patients. We showed that symptoms occur statistically more often in patients with mixed type of disease after pacemaker implantation.
Okamura, Hideo; Padmanabhan, Deepak; Watson, Robert E; Dalzell, Connie; Acker, Nancy; Jondal, Mary; Romme, Abby L; Cha, Yong-Mei; Asirvatham, Samuel J; Felmlee, Joel P; Friedman, Paul A
2017-05-01
Magnetic resonance imaging (MRI) in patients with non-MRI-conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported. Prospective data were collected between January 2008 and May 2015 in patients with non-MRI-conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events. MRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power-on-reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005. Patients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing. © 2017 Wiley Periodicals, Inc.
Jadidi, Amir S; Lehrmann, Heiko; Keyl, Cornelius; Sorrel, Jérémie; Markstein, Viktor; Minners, Jan; Park, Chan-Il; Denis, Arnaud; Jaïs, Pierre; Hocini, Mélèze; Potocnik, Clemens; Allgeier, Juergen; Hochholzer, Willibald; Herrera-Sidloky, Claudia; Kim, Steve; Omri, Youssef El; Neumann, Franz-Josef; Weber, Reinhold; Haïssaguerre, Michel; Arentz, Thomas
2016-03-01
Complex-fractionated atrial electrograms and atrial fibrosis are associated with maintenance of persistent atrial fibrillation (AF). We hypothesized that pulmonary vein isolation (PVI) plus ablation of selective atrial low-voltage sites may be more successful than PVI only. A total of 85 consecutive patients with persistent AF underwent high-density atrial voltage mapping, PVI, and ablation at low-voltage areas (LVA < 0.5 mV in AF) associated with electric activity lasting > 70% of AF cycle length on a single electrode (fractionated activity) or multiple electrodes around the circumferential mapping catheter (rotational activity) or discrete rapid local activity (group I). The procedural end point was AF termination. Arrhythmia freedom was compared with a control group (66 patients) undergoing PVI only (group II). PVI alone was performed in 23 of 85 (27%) patients of group I with low amount (< 10% of left atrial surface area) of atrial low voltage. Selective atrial ablation in addition to PVI was performed in 62 patients with termination of AF in 45 (73%) after 11 ± 9 minutes radiofrequency delivery. AF-termination sites colocalized within LVA in 80% and at border zones in 20%. Single-procedural arrhythmia freedom at 13 months median follow-up was achieved in 59 of 85 (69%) patients in group I, which was significantly higher than the matched control group (31/66 [47%], P < 0.001). There was no significant difference in the success rate of patients in group I with a low amount of low voltage undergoing PVI only and patients requiring PVI+selective low-voltage ablation (P = 0.42). Ablation of sites with distinct activation characteristics within/at borderzones of LVA in addition to PVI is more effective than conventional PVI-only strategy for persistent AF. PVI only seems to be sufficient to treat patients with left atrial low voltage < 10%. © 2016 American Heart Association, Inc.
Cardiac pacemaker dysfunction in children after thoracic drainage catheter manipulation.
Lobdell, K W; Walters, H L; Hudson, C; Hakimi, M
1997-05-01
Two children underwent placement of permanent, epicardial-lead, dual-chamber, unipolar pacemaker systems for complete heart block. Postoperatively, both patients demonstrated subcutaneous emphysema-in the area of their pulse generators-temporally related to thoracic catheter manipulation. Acutely, each situation was managed with manual compression of the pulse generator, ascertaining appropriate pacemaker sensing and pacing. Maintenance of compression with pressure dressings, vigilant observation/monitoring, and education of the care givers resulted in satisfactory pacemaker function without invasive intervention.
What Pacemakers Can Teach Us about the Ethics of Maintaining Artificial Organs.
Hutchison, Katrina; Sparrow, Robert
2016-11-01
One day soon it may be possible to replace a failing heart, liver, or kidney with a long-lasting mechanical replacement or perhaps even with a 3-D printed version based on the patient's own tissue. Such artificial organs could make transplant waiting lists and immunosuppression a thing of the past. Supposing that this happens, what will the ongoing care of people with these implants involve? In particular, how will the need to maintain the functioning of artificial organs over an extended period affect patients and their doctors and the responsibilities of those who manufacture such devices? Drawing on lessons from the history of the cardiac pacemaker, this article offers an initial survey of the ethical issues posed by the need to maintain and service artificial organs. We briefly outline the nature and history of cardiac pacemakers, with a particular focus on the need for technical support, maintenance, and replacement of these devices. Drawing on the existing medical literature and on our conversations and correspondence with cardiologists, regulators, and manufacturers, we describe five sources of ethical issues associated with pacemaker maintenance: the location of the devices inside the human body, such that maintenance generates surgical risks; the complexity of the devices, which increases the risk of harms to patients as well as introducing potential injustices in access to treatment; the role of software-particularly software that can be remotely accessed-in the functioning of the devices, which generates privacy and security issues; the impact of continual development and improvement of the device; and the influence of commercial interests in the context of a medical device market in which there are several competing products. Finally, we offer some initial suggestions as to how these questions should be answered. © 2016 The Hastings Center.
Influence of internal current and pacing current on pacemaker longevity.
Schuchert, A; Kuck, K H
1994-01-01
The effects of lower pulse amplitude on battery current and pacemaker longevity were studied comparing the new, small-sized VVI pacemaker, Minix 8341, with the former model, Pasys 8329. Battery current was telemetrically measured at 0.8, 1.6, 2.5, and 5.0 V pulse amplitude and 0.05, 0.25, 0.5, and 1.0 msec pulse duration. Internal current was assumed to be equal to the battery current at 0.8 V and 0.05 msec. Pacing current was calculated subtracting internal current from battery current. The Minix pacemaker had a significantly lower battery current because of a lower internal current (Minix: 4.1 +/- 0.1 microA; Pasys: 16.1 +/- 0.1 microA); pacing current of both units was similar. At 0.5 msec pulse duration, the programming from 5.0-2.5 V pulse amplitude resulted in a greater relative reduction of battery current in the newer pacemaker (51% vs 25%). Projected longevity of each pacemaker was 7.9 years at 5.0 V and 0.5 msec. The programming from 5.0-2.5 V extended the projected longevity by 2.3 years (Pasys) and by 7.1 years (Minix). The longevity was negligibly longer after programming to 1.6 V. extension of pacemaker longevity can be achieved with the programming to 2.5 V or less if the connected pacemakers need a low internal current for their circuitry.
Lin, Yu-Sheng; Chen, Tien-Hsing; Hung, Sheng-Ping; Chen, Dong Yi; Mao, Chun-Tai; Tsai, Ming-Lung; Chang, Shih-Tai; Wang, Chun-Chieh; Wen, Ming-Shien; Chen, Mien-Cheng
2015-01-01
Several risk factors for pacemaker (PM) related complications have been reported. However, no study has investigated the impact of lead characteristics on pacemaker-related complications. Patients who received a new pacemaker implant from January 1997 to December 2011 were selected from the Taiwan National Health Insurance Database. This population was grouped according to the pacemaker lead characteristics in terms of fixation and insulation. The impact of the characteristics of leads on early heart perforation was analyzed by multivariable logistic regression analysis, while the impact of the lead characteristics on early and late infection and late heart perforation over a three-year period were analyzed using Cox regression. This study included 36,104 patients with a mean age of 73.4±12.5 years. In terms of both early and late heart perforations, there were no significant differences between groups across the different types of fixation and insulations. In the multivariable Cox regression analysis, the pacemaker-related infection rate was significantly lower in the active fixation only group compared to either the both fixation (OR, 0.23; 95% CI, 0.07-0.80; P = 0.020) or the passive fixation group (OR, 0.26; 95% CI, 0.08-0.83; P = 0.023). There was no difference in heart perforation between active and passive fixation leads. Active fixation leads were associated with reduced risk of pacemaker-related infection.
Shenthar, Jayaprakash; Rai, Maneesh K; Walia, Rohit; Ghanta, Somasekhar; Sreekumar, Praveen; Reddy, Satish S
2014-09-01
Dextrocardia is a rare congenital anomaly. Pacemaker implantation in dextrocardia can be challenging because of the distorted anatomy and associated anomalies. The literature regarding implantation of pacemaker in dextrocardia is scarce. The study involved retrospective analysis of records of patients with dextrocardia who had undergone pacemaker implantation between January 2006 and July 2013 from a single centre. Six patients with dextrocardia (five males and one female) underwent permanent pacemaker implantation (PPI) between January 2006 and July 2013. Of them, three had situs solitus dextrocardia and three situs inversus dextrocardia. All three patients with situs solitus dextrocardia had associated corrected transposition of great arteries. The indication for pacemaker implantation was symptomatic complete atrioventricular (AV) block in four, high-grade AV block in one, and sinus node dysfunction in one patient. A favourable outcome was noted during a mean follow-up of 3.9 years (4 months to 7 years) with one patient needing a pulse generator replacement. Permanent pacemaker implantation in dextrocardia can be challenging because of the distorted anatomy. Use of a technique employing angiography to delineate chamber anatomy and relationship can assist the operator during such difficult PPIs. The medium- and long-term survival after a successful pacemaker implantation in dextrocardia is favourable. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Conduction disturbances after TAVR: Electrophysiological studies and pacemaker dependency.
Makki, Nader; Dollery, Jenn; Jones, Danielle; Crestanello, Juan; Lilly, Scott
Permanent pacemaker (PPM) placement occurs in 5-20% of patients after transcatheter aortic valve replacement (TAVR). Although predictors of pacemaker implantation have been established, features that predispose patients to pacemaker utilization on follow up have not been widely reported. We performed a retrospective review of patients undergoing commercial TAVR between 2011 and 2016. We collated patients that underwent in-hospital PPM implantation and had a follow up of at least 3months. Data abstraction was performed for electrophysiological studies (EPS), pacemaker indication, timing, and device interrogation for pacemaker dependency on follow up. A total of 24 patients received in-hospital PPM post-TAVR (14% of total cohort), and mean follow up was 22months. Indications for PPM included resting complete heart block (CHB; 15/24, 63%), left bundle branch block and abnormal electrophysiological study (EPS; 7/24, 29%), alternating bundle branch block (1/24, 4%) and tachy-brady syndrome (1/24, 4%). Pacemaker dependency (underlying ventricular asystole, complete heart block, or >50% pacing) occurred in 8/24 patients (33%) during follow-up, 7 of whom had resting CHB, and one with CHB invoked during EPS. Pacemaker dependency after TAVR is common among those that exhibited CHB, but not among those with a prolonged HV delay during EPS. Although preliminary, these observations are relevant to management of rhythm disturbances after TAVR, and may inform the practice of EPS-based PPM implantation. Copyright © 2017 Elsevier Inc. All rights reserved.
Neck Pain One Week after Pacemaker Generator Replacement.
Graham, Ross F; Wightman, John M
2015-07-01
The incidence of cardiac pacemaker implantation has risen markedly in the past three decades, making awareness of possible postprocedural complications critical to the emergency physician. This case is the first documented instance of internal jugular (IJ) deep vein thrombosis (DVT) from an uncomplicated pacemaker generator replacement. A patient presented to an Emergency Department with a 2-day history of mild left temporal headache migrating to his left neck. The patient did not volunteer this information, but review of systems revealed a temporary transvenous pacemaker inserted through the right IJ vein 1 week previously during a routine exchange of a left-sided cardiac pacemaker generator. Manipulation of the existing pacemaker wires entering the left subclavian vein was minimal. Computed tomographic angiography of the neck demonstrated near-complete thrombotic occlusion of the entire length of his left IJ vein. This required hospital admission for observation and treatment with anticoagulation. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: DVT, with thrombotic extension into adjacent vessels anywhere along the course of pacemaker wires, should be considered by the emergency provider in the evaluation of head, neck, or upper extremity symptoms after recent or remote implantation or manipulation of a transvenous cardiac pacemaker, including generator replacement. Failure to identify and treat appropriately could result in significant morbidity and mortality from airway edema, septic thrombophlebitis, superior vena cava syndrome, superior sagittal sinus thrombosis, or pulmonary embolism. Published by Elsevier Inc.
So, Keum Young; Kim, Sang Hun; Sohn, Hong Moon; Choi, Soo Jin; Parajuli, Shankar Prasad; Choi, Seok; Yeum, Cheol Ho; Yoon, Pyung Jin; Jun, Jae Yeoul
2009-05-31
We studied the effect of carbachol on pacemaker currents in cultured interstitial cells of Cajal (ICC) from the mouse small intestine by muscarinic stimulation using a whole cell patch clamp technique and Ca2+-imaging. ICC generated periodic pacemaker potentials in the current-clamp mode and generated spontaneous inward pacemaker currents at a holding potential of-70 mV. Exposure to carbachol depolarized the membrane and produced tonic inward pacemaker currents with a decrease in the frequency and amplitude of the pacemaker currents. The effects of carbachol were blocked by 1-dimethyl-4-diphenylacetoxypiperidinium, a muscarinic M(3) receptor antagonist, but not by methotramine, a muscarinic M(2) receptor antagonist. Intracellular GDP-beta-S suppressed the carbachol-induced effects. Carbachol-induced effects were blocked by external Na+-free solution and by flufenamic acid, a non-selective cation channel blocker, and in the presence of thapsigargin, a Ca2+-ATPase inhibitor in the endoplasmic reticulum. However, carbachol still produced tonic inward pacemaker currents with the removal of external Ca2+. In recording of intracellular Ca2+ concentrations using fluo 3-AM dye, carbachol increased intracellular Ca2+ concentrations with increasing of Ca2+ oscillations. These results suggest that carbachol modulates the pacemaker activity of ICC through the activation of non-selective cation channels via muscarinic M(3) receptors by a G-protein dependent intracellular Ca2+ release mechanism.
Phan, Kevin; Xie, Ashleigh; Kumar, Narendra; Wong, Sophia; Medi, Caroline; La Meir, Mark; Yan, Tristan D
2015-08-01
Simplified maze procedures involving radiofrequency, cryoenergy and microwave energy sources have been increasingly utilized for surgical treatment of atrial fibrillation as an alternative to the traditional cut-and-sew approach. In the absence of direct comparisons, a Bayesian network meta-analysis is another alternative to assess the relative effect of different treatments, using indirect evidence. A Bayesian meta-analysis of indirect evidence was performed using 16 published randomized trials identified from 6 databases. Rank probability analysis was used to rank each intervention in terms of their probability of having the best outcome. Sinus rhythm prevalence beyond the 12-month follow-up was similar between the cut-and-sew, microwave and radiofrequency approaches, which were all ranked better than cryoablation (respectively, 39, 36, and 25 vs 1%). The cut-and-sew maze was ranked worst in terms of mortality outcomes compared with microwave, radiofrequency and cryoenergy (2 vs 19, 34, and 24%, respectively). The cut-and-sew maze procedure was associated with significantly lower stroke rates compared with microwave ablation [odds ratio <0.01; 95% confidence interval 0.00, 0.82], and ranked the best in terms of pacemaker requirements compared with microwave, radiofrequency and cryoenergy (81 vs 14, and 1, <0.01% respectively). Bayesian rank probability analysis shows that the cut-and-sew approach is associated with the best outcomes in terms of sinus rhythm prevalence and stroke outcomes, and remains the gold standard approach for AF treatment. Given the limitations of indirect comparison analysis, these results should be viewed with caution and not over-interpreted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Personalized and automated remote monitoring of atrial fibrillation.
Rosier, Arnaud; Mabo, Philippe; Temal, Lynda; Van Hille, Pascal; Dameron, Olivier; Deléger, Louise; Grouin, Cyril; Zweigenbaum, Pierre; Jacques, Julie; Chazard, Emmanuel; Laporte, Laure; Henry, Christine; Burgun, Anita
2016-03-01
Remote monitoring of cardiac implantable electronic devices is a growing standard; yet, remote follow-up and management of alerts represents a time-consuming task for physicians or trained staff. This study evaluates an automatic mechanism based on artificial intelligence tools to filter atrial fibrillation (AF) alerts based on their medical significance. We evaluated this method on alerts for AF episodes that occurred in 60 pacemaker recipients. AKENATON prototype workflow includes two steps: natural language-processing algorithms abstract the patient health record to a digital version, then a knowledge-based algorithm based on an applied formal ontology allows to calculate the CHA2DS2-VASc score and evaluate the anticoagulation status of the patient. Each alert is then automatically classified by importance from low to critical, by mimicking medical reasoning. Final classification was compared with human expert analysis by two physicians. A total of 1783 alerts about AF episode >5 min in 60 patients were processed. A 1749 of 1783 alerts (98%) were adequately classified and there were no underestimation of alert importance in the remaining 34 misclassified alerts. This work demonstrates the ability of a pilot system to classify alerts and improves personalized remote monitoring of patients. In particular, our method allows integration of patient medical history with device alert notifications, which is useful both from medical and resource-management perspectives. The system was able to automatically classify the importance of 1783 AF alerts in 60 patients, which resulted in an 84% reduction in notification workload, while preserving patient safety. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Drzewiecki, J; Trusz-Gluza, M; Wnuk-Wojnar, A; Jaklik, A; Czerwiński, C; Filipecki, A; Szydło, K; Ciemniewski, Z; Giec, L
1993-01-01
Since the first successful therapeutic DC ablation of the AV junction in 1986, we have treated 20 symptomatic patients with drug-refractory supraventricular tachyarrhythmias (average of 6 antiarrhythmic drugs prior to the ablation attempt). The primary rhythm disturbances necessitating ablation were: AV nodal reentrant tachycardia (50% of pts), atrial flutter or fibrillation, with an uncontrolled rapid ventricular response (40%), atrioventricular reentrant tachycardia using an accessory pathway (20%), atrial tachycardia (10%), and junctional reciprocating tachycardia (5%). Percutaneous catheter ablation of the AV junction was made by Gallagher's method. The USCI 4-polar catheter (7F) was used in 40% of pts, and bipolar Cordis catheter (5F) in the remaining 60%. 70% of pts received either one or two shocks, usually of 200 or 300 J during one session. Another 25% received stored cumulative energy from 800 to 1200 J (in two sessions), and one patient--1800 J (during three sessions). In 85% of pts, the immediate post-ablation conduction was third-degree AV block with the escape pacemaker, ranging from 20 to 50 beats/min., which was infra-His in 57%, and supra-His in 43% of pts. In 15% of pts were either first-degree AV block (10%) or normal AV conduction (5%). A His bundle deflection more than 0.2 mV was predictive of successful production of third-degree AV block. Except a mild and transient increase of indicating enzymes (CPK and CPK-MB) we did not observe any other serious complications directly related to the ablalation procedure. Follow-up study included 19 pts (time range from 2 to 56 months, mean 28).(ABSTRACT TRUNCATED AT 250 WORDS)
Differentiation induction of mouse embryonic stem cells into sinus node-like cells by suramin
Wiese, Cornelia; Nikolova, Teodora; Zahanich, Ihor; Sulzbacher, Sabine; Fuchs, Joerg; Yamanaka, Satoshi; Graf, Eva; Ravens, Ursula; Boheler, Kenneth R.; Wobus, Anna M.
2015-01-01
Background Embryonic stem (ES) cells differentiate into cardiac phenotypes representing early pacemaker-, atrial-, ventricular-, and sinus node-like cells, however, ES-derived specification into sinus nodal cells is not yet known. By using the naphthylamine derivative of urea, suramin, we were able to follow the process of cardiac specialization into sinus node-like cells. Methods Differentiating mouse ES cells were treated with suramin (500 μM) from day 5 to 7 of embryoid body formation, and cells were analysed for their differentiation potential via morphological analysis, flow cytometry, RT-PCR, immunohistochemistry and patch clamp analysis. Results Application of suramin resulted in an increased number of cardiac cells, but inhibition of neuronal, skeletal muscle and definitive endoderm differentiation. Immediately after suramin treatment, a decreased mesendoderm differentiation was found. Brachyury, FGF10, Wnt8 and Wnt3a transcript levels were significantly down-regulated, followed by a decrease in mesoderm- and cardiac progenitor-specific markers BMP2, GATA4/5, Wnt11, Isl1, Nkx2.5 and Tbx5 immediately after removal of the substance. With continued differentiation, a significant up-regulation of Brachyury, FGF10 and GATA5 transcript levels was observed, whereas Nkx2.5, Isl1, Tbx5, BMP2 and Wnt11 levels were normalized to control levels. At advanced differentiation stages, sinus node-specific HCN4, Tbx2 and Tbx3 transcript levels were significantly up-regulated. Immunofluorescence and patch-clamp analysis confirmed the increased number of sinus node-like cells, and electrophysiological analysis revealed a lower number of atrial- and ventricular-like cardiomyocytes following suramin treatment. Conclusion We conclude that the interference of suramin with the cardiac differentiation process modified mesoderm- and cardiac-specific gene expression resulting in enhanced formation of sinus node-like cells. PMID:19775764
Kiuchi, Márcio Galindo; Chen, Shaojie; Hoye, Neil Alexander; Pürerfellner, Helmut
2018-01-01
Atrial fibrillation (AF) commonly occurs in chronic kidney disease (CKD), occasioning adverse outcomes. Merging pulmonary vein isolation (PVI) and renal sympathetic denervation (RSD) may decrease the recurrence of AF in subjects with CKD and uncontrolled hypertension. We considered that RSD could reduce the recurrence of AF in patients with CKD by modulating sympathetic hyperactivity. We aimed to evaluate the impact of RSD or spironolactone 50 mg/day associated with PVI in reducing systolic blood pressure (BP), AF recurrence, and AF burden in patients with a history of paroxysmal AF and mild CKD. This was a single-center, prospective, longitudinal, randomized, double-blind study. The individuals were randomly divided into two groups (PVI + spironolactone, n = 36, and PVI + RSD, n = 33). All of them were followed for exactly 1 year to assess maintenance of sinus rhythm and to monitor the other variables. Ambulatory BP measurements were reduced in both groups and at the 12th month also differed between groups. Significantly more patients in the PVI + RSD (61%) than in the PVI + spironolactone group (36%) were AF-free at the 12th month of follow-up, P = 0.0242. Toward the end of the study, the mean AF burden was lower in the PVI + RSD group as compared to PVI + spironolactone group, at the 9th month: ∆ = - 10% (P < 0.0001), and at the 12th month: ∆ = - 12% (P < 0.0001), respectively. PVI + RSD is safe and appears to be superior to PVI + spironolactone in BP reduction, augmentation of AF event-free rate, reduction of AF burden, and improvement of renal function.
Jama, Zimasa V; Chin, Ashley; Mayosi, Bongani M; Badri, Motasim
2015-01-01
Objectives Little is known about the performance of re-used pacemakers and implantable cardioverter defibrillators (ICDs) in Africa. We sought to compare the risk of infection and the rate of malfunction of re-used pacemakers and ICDs with new devices implanted at Groote Schuur Hospital in Cape Town, South Africa. Methods This was a retrospective case comparison study of the performance of re-used pacemakers and ICDs in comparison with new devices implanted at Groote Schuur Hospital over a 10-year period. The outcomes were incidence of device infection, device malfunction, early battery depletion, and device removal due to infection, malfunction, or early battery depletion. Results Data for 126 devices implanted in 126 patients between 2003 and 2013 were analysed, of which 102 (81%) were pacemakers (51 re-used and 51 new) and 24 (19%) were ICDs (12 re-used and 12 new). There was no device infection, malfunction, early battery depletion or device removal in either the re-used or new pacemaker groups over the median follow up of 15.1 months [interquartile range (IQR), 1.3–36.24 months] for the re-used pacemakers, and 55.8 months (IQR, 20.3–77.8 months) for the new pacemakers. In the ICD group, no device infection occurred over a median follow up of 35.9 months (IQR, 17.0–70.9 months) for the re-used ICDs and 45.7 months (IQR, 37.6–53.7 months) for the new ICDs. One device delivered inappropriate shocks, which resolved without intervention and with no harm to the patient. This re-used ICD subsequently needed generator replacement 14 months later. In both the pacemaker and ICD groups, there were no procedure-non-related infections documented for the respective follow-up periods. Conclusion No significant differences were found in performance between re-used and new pacemakers and ICDs with regard to infection rates, device malfunction, battery life and device removal for complications. Pacemaker and ICD re-use is feasible and safe and is a viable option for patients with bradyarrhythmias and tachyarrthythmias. PMID:26407220
Provost, Jean; Costet, Alexandre; Wan, Elaine; Gambhir, Alok; Whang, William; Garan, Hasan; Konofagou, Elisa E.
2015-01-01
Minimally-invasive treatments of cardiac arrhythmias such as radio-frequency ablation are gradually gaining in importance in clinical practice but still lack a noninvasive imaging modality which provides insight into the source or focus of an arrhythmia. Cardiac deformations imaged at high temporal and spatial resolution can be used to elucidate the electrical activation sequence in normal and paced human subjects non-invasively and could potentially aid to better plan and monitor ablation-based arrhythmia treatments. In this study, a novel ultrasound-based method is presented that can be used to quantitatively characterize focal and reentrant arrhythmias. Spatio-temporal maps of the full-view of the atrial and ventricular mechanics were obtained in a single heartbeat, revealing with otherwise unobtainable detail the electromechanical patterns of atrial flutter, fibrillation, and tachycardia in humans. During focal arrhythmias such as premature ventricular complex and focal atrial tachycardia, the previously developed electromechanical wave imaging methodology is hereby shown capable of identifying the location of the focal zone and the subsequent propagation of cardiac activation. During reentrant arrhythmias such as atrial flutter and fibrillation, Fourier analysis of the strains revealed highly correlated mechanical and electrical cycle lengths and propagation patterns. High frame rate ultrasound imaging of the heart can be used non-invasively and in real time, to characterize the lesser-known mechanical aspects of atrial and ventricular arrhythmias, also potentially assisting treatment planning for intraoperative and longitudinal monitoring of arrhythmias. PMID:26361338
... your pacemaker. • If you work around industrial microwaves, electricity, cars or other large motors, ask your doctor about possible effects. Can I use a cell phone or microwave oven if I have a pacemaker? Microwave ovens, electric blankets, remote controls for TV and other common ...
21 CFR 870.3700 - Pacemaker programmers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker programmers. 870.3700 Section 870.3700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3700 Pacemaker programmers...
Haemophilus parainfluenzae bacteremia associated with a pacemaker wire localized by gallium scan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenbaum, G.S.; Calubiran, O.; Cunha, B.A.
1990-05-01
A young woman with a history of sick sinus syndrome and placement of a permanent pacemaker 6 months before admission had fever and Haemophilus parainfluenzae bacteremia. A gallium scan localized the infection to the site of the pacemaker wire. Echocardiograms were negative for any vegetations. The patient responded to cefotaxime and trimethoprim-sulfamethoxazole therapy. We believe that this is the first case of H. parainfluenzae bacteremia associated with a pacemaker wire and localized by gallium scan.
Of pacemakers and statistics: the actuarial method extended.
Dussel, J; Wolbarst, A B; Scott-Millar, R N; Obel, I W
1980-01-01
Pacemakers cease functioning because of either natural battery exhaustion (nbe) or component failure (cf). A study of four series of pacemakers shows that a simple extension of the actuarial method, so as to incorporate Normal statistics, makes possible a quantitative differentiation between the two modes of failure. This involves the separation of the overall failure probability density function PDF(t) into constituent parts pdfnbe(t) and pdfcf(t). The approach should allow a meaningful comparison of the characteristics of different pacemaker types.
2005-09-01
of a system to store and retrieve digital/ wireless communication information from a pacemaker/ defibrillator, or other device , and to alert medical... wireless communication information from a pacemaker/defibrillator, or other device , and to alert medical personnel when a person is experiencing...with heart, pacing, program, test, sensor , circuit) where the individual needs immediate attention an audible alert will go off at the nurse’s
Huang, Allen R; Redpath, Calum J; van Walraven, Carl
2015-04-28
Cholinesterase inhibitors are used to treat the symptoms of dementia and can theoretically cause bradycardia. Previous studies suggest that patients taking these medications have an increased risk of undergoing pacemaker insertion. Since these drugs have a marginal impact on patient outcomes, it might be preferable to change drug treatment rather than implant a pacemaker. This population-based study determined the association of people with dementia exposed to cholinesterase inhibitor medication and pacemaker insertion. We used data from the Ontario health administrative databases from January 1, 1993 to June 30, 2012. We included all community-dwelling seniors who had a code for dementia and were exposed to cholinesterase inhibitors (donezepil, galantamine, and rivastigmine) and/or drugs used to treat co-morbidities of hypertension, diabetes, depression and hypothyroidism. We controlled for exposure to anti-arrhythmic drugs. Observation started at first exposure to any medication and continued until the earliest of pacemaker insertion, death, or end of study. 2,353,909 people were included with 96,000 (4.1%) undergoing pacemaker insertion during the observation period. Case-control analysis showed that pacemaker patients were less likely to be coded with dementia (unadjusted OR 0.42 [95%CI 0.41-0.42]) or exposed to cholinesterase inhibitors (unadjusted OR 0.39 [95%CI 0.37-0.41]). That Cohort analysis showed patients with dementia taking cholinesterase inhibitors had a decreased risk of pacemaker insertion (unadj-HR 0.58 [0.55-0.61]). Adjustment for patient age, sex, and other medications did not notably change results, as did restricting the analysis to incident users. Patients taking cholinesterase inhibitors rarely undergo, and have a significantly reduced risk of, cardiac pacemaker insertion.
Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia
2015-01-01
The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Li, Jie; Blankenship, Meredith L.; Baccei, Mark L.
2013-01-01
Pacemaker neurons in neonatal spinal nociceptive circuits generate intrinsic burst-firing and are distinguished by a lower “leak” membrane conductance compared to adjacent, non-bursting neurons. However, little is known about which subtypes of leak channels regulate the level of pacemaker activity within the developing rat superficial dorsal horn (SDH). Here we demonstrate that a hallmark feature of lamina I pacemaker neurons is a reduced conductance through inward-rectifying potassium (Kir) channels at physiological membrane potentials. Differences in the strength of inward rectification between pacemakers and non-pacemakers indicate the presence of functionally distinct Kir currents in these two populations at room temperature. However, Kir currents in both groups showed high sensitivity to block by extracellular Ba2+ (IC50 ~ 10 µM), which suggests the presence of ‘classical’ Kir (Kir2.x) channels in the neonatal SDH. The reduced Kir conductance within pacemakers is unlikely to be explained by an absence of particular Kir2.x isoforms, as immunohistochemical analysis revealed the expression of Kir2.1, Kir2.2 and Kir2.3 within spontaneously bursting neurons. Importantly, Ba2+ application unmasked rhythmic burst-firing in ~42% of non-bursting lamina I neurons, suggesting that pacemaker activity is a latent property of a sizeable population of SDH cells during early life. In addition, the prevalence of spontaneous burst-firing within lamina I was enhanced in the presence of high internal concentrations of free Mg2+, consistent with its documented ability to block Kir channels from the intracellular side. Collectively, the results indicate that Kir channels are key modulators of pacemaker activity in newborn central pain networks. PMID:23426663
Effect of monopolar radiofrequency energy on pacemaker function.
Govekar, Henry R; Robinson, Thomas N; Varosy, Paul D; Girard, Guillaume; Montero, Paul N; Dunn, Christina L; Jones, Edward L; Stiegmann, Greg V
2012-10-01
This study aimed to quantify the clinical parameters of mono- and bipolar instruments that inhibit pacemaker function. The specific aims were to quantify pacer inhibition resulting from the monopolar instrument by altering the generator power setting, the generator mode, the distance between the active electrode and the pacemaker, and the location of the dispersive electrode. A transvenous ventricular lead pacemaker overdrive paced the native heart rate of an anesthetized pig. The primary outcome variable was pacer inhibition quantified as the number of beats dropped by the pacemaker during 5 s of monopolar active electrode activation. Lowering the generator power setting from 60 to 30 W decreased the number of dropped paced events (2.3 ± 1.2 vs 1.6 ± 0.8 beats; p = 0.045). At 30 W of power, use of the cut mode decreased the number of dropped paced beats compared with the coagulation mode (0.6 ± 0.5 vs 1.6 ± 0.8; p = 0.015). At 30 W coagulation, firing the active electrode at different distances from the pacemaker generator (3.75, 7.5, 15, and 30 cm) did not change the number of dropped paced beats (p = 0.314, analysis of variance [ANOVA]). The dispersive electrode was placed in four locations (right/left gluteus, right/left shoulder). More paced beats were dropped when the current vector traveled through the pacemaker/leads than when it did not (1.5 ± 1.0 vs 0.2 ± 0.4; p < 0.001). Clinical parameters that reduce the inhibition of a pacemaker by monopolar instruments include lowering the generator power setting, using cut (vs coagulation) mode, and locating the dispersive electrode so the current vector does not traverse the pacemaker generator or leads.
Yodogawa, Kenji; Ono, Norihiko; Seino, Yoshihiko
2012-01-01
A 56-year-old man was admitted because of palpitations and dyspnea. A 12-lead electrocardiogram showed irregular wide QRS complex tachycardia with a slur at the initial portion of the QRS complex. He had preexisting long-standing persistent atrial fibrillation, but early excitation syndrome had never been noted. Chest X-ray showed heart enlargement and pulmonary congestion. He was diagnosed with late onset of Wolff-Parkinson-White syndrome, and congestive heart failure was probably caused by rapid ventricular response of atrial fibrillation through the accessory pathway. Emergency catheter ablation for the accessory pathway was undertaken, and heart failure was dramatically improved.
Current facts on pacemaker electromagnetic interference and their application to clinical care
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sager, D.P.
1987-03-01
The development of the sensing demand cardiac pacemaker brought with it the problem of interference as a result of extraneous electric current and electromagnetic fields. This problem still deserves consideration, not only because harmful disruption of pacemaker function, while infrequent, can occur but also because myths and misunderstandings have flourished on the subject. Misinformation has often led to needless patient anxiety and unnecessary restrictions in activities of daily living. Similarly, when health care practitioners are misinformed about pacemaker interference, potentially hazardous situations can occur in the clinical environment. This article is a review of current information on the sources andmore » effects of electromagnetic interference (EMI) on pacemakers and includes a discussion of their application to patient care.« less
Djani, D M; Coleman, A E; Rapoport, G S; Schmiedt, C W; Layher, J; Thomason, J D
2016-12-01
A 16-year-old dog was presented for cough as well as increased respiratory rate and effort three years after implantation of a single-lead transvenous artificial pacemaker system. Thoracic radiographs and echocardiography disclosed prolapse of the pacemaker lead into the main pulmonary artery, causing severe pulmonary insufficiency and right-sided volume overload. Repositioning of the pacemaker lead led to improvement of pulmonary insufficiency and resolution of the dog's clinical signs and cavitary effusions. This case describes a late complication of pacemaker implantation that may be avoided by appropriate use of the manufacturer-provided anchoring sleeve and avoidance of excessive lead redundancy. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muller-Runkel, R.; Orsolini, G.; Kalokhe, U.P.
1990-11-01
Multiprogrammable pacemakers, using complimentary metaloxide semiconductor (CMOS) circuitry, may fail during radiation therapy. We report about a patient who received 6,400 cGy for unresectable carcinoma of the left lung. In supine treatment position, arms raised above the head, the pacemaker was outside the treated area by a margin of at least 1 cm, shielded by cerrobend blocking mounted on a tray. From thermoluminescent dosimeter (TLD) measurements, we estimate that the pacemaker received 620 cGy in scatter doses. Its function was monitored before, during, and after completion of radiation therapy. The pacemaker was functioning normally until the patient's death 5 monthsmore » after completion of treatment. The relevant electrocardiograms (ECGs) are presented.« less
21 CFR 870.3670 - Pacemaker charger.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker charger. 870.3670 Section 870.3670 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3670 Pacemaker charger. (a...
Atrial tachyarrhythmia in adult congenital heart disease
Karbassi, Arsha; Nair, Krishnakumar; Harris, Louise; Wald, Rachel M; Roche, S Lucy
2017-01-01
The adult congenital heart disease (ACHD) population continues to grow and most cardiologists, emergency room physicians and family doctors will intermittently come into contact with these patients. Oftentimes this may be in the setting of a presentation with atrial tachyarrhythmia; one of the commonest late complications of ACHD and problem with potentially serious implications. Providing appropriate initial care and ongoing management of atrial tachyarrhythmia in ACHD patients requires a degree of specialist knowledge and an awareness of certain key issues. In ACHD, atrial tachyarrhythmia is usually related to the abnormal anatomy of the underlying heart defect and often occurs as a result of surgical scar or a consequence of residual hemodynamic or electrical disturbances. Arrhythmias significantly increase mortality and morbidity in ACHD and are the most frequent reason for ACHD hospitalization. Intra-atrial reentrant tachycardia and atrial fibrillation are the most prevalent type of arrhythmia in this patient group. In hemodynamically unstable patients, urgent cardioversion is required. Acute management of the stable patient includes anticoagulation, rate control, and electrical or pharmacological cardioversion. In ACHD, rhythm control is the preferred management strategy and can often be achieved. However, in the long-term, medication side-effects can prove problematic. Electrophysiology studies and catheter ablation are important treatments modalities and in certain cases, surgical or percutaneous treatment of the underlying cardiac defect has a role. ACHD patients, especially those with complex CHD, are at increased risk of thromboembolic events and anticoagulation is usually required. Female ACHD patients of child bearing age may wish to pursue pregnancies. The risk of atrial arrhythmias is increased during pregnancy and management of atrial tachyarrhythmia during pregnancy needs specific consideration. PMID:28706585
Ugarte, Juan P.; Orozco-Duque, Andrés; Tobón, Catalina; Kremen, Vaclav; Novak, Daniel; Saiz, Javier; Oesterlein, Tobias; Schmitt, Clauss; Luik, Armin; Bustamante, John
2014-01-01
There is evidence that rotors could be drivers that maintain atrial fibrillation. Complex fractionated atrial electrograms have been located in rotor tip areas. However, the concept of electrogram fractionation, defined using time intervals, is still controversial as a tool for locating target sites for ablation. We hypothesize that the fractionation phenomenon is better described using non-linear dynamic measures, such as approximate entropy, and that this tool could be used for locating the rotor tip. The aim of this work has been to determine the relationship between approximate entropy and fractionated electrograms, and to develop a new tool for rotor mapping based on fractionation levels. Two episodes of chronic atrial fibrillation were simulated in a 3D human atrial model, in which rotors were observed. Dynamic approximate entropy maps were calculated using unipolar electrogram signals generated over the whole surface of the 3D atrial model. In addition, we optimized the approximate entropy calculation using two real multi-center databases of fractionated electrogram signals, labeled in 4 levels of fractionation. We found that the values of approximate entropy and the levels of fractionation are positively correlated. This allows the dynamic approximate entropy maps to localize the tips from stable and meandering rotors. Furthermore, we assessed the optimized approximate entropy using bipolar electrograms generated over a vicinity enclosing a rotor, achieving rotor detection. Our results suggest that high approximate entropy values are able to detect a high level of fractionation and to locate rotor tips in simulated atrial fibrillation episodes. We suggest that dynamic approximate entropy maps could become a tool for atrial fibrillation rotor mapping. PMID:25489858
Kim, Doeun; Kim, Jung Nam; Nam, Joo Hyun; Lee, Jong Rok; Kim, Sang Chan; Kim, Byung Joo
2018-04-19
The Gamisoyo-san (GSS) has been used for -improving the gastrointestinal (GI) symptoms. The purpose of this study was to investigate the effects of GSS, a traditional Chinese herbal medicine, on the pacemaker potentials of mouse small intestinal interstitial cells of Cajal (ICCs). ICCs from the small intestines were dissociated and cultured. Whole-cell patch-clamp configuration was used to record pacemaker potentials and membrane currents. GSS depolarized ICC pacemaker potentials in a dose-dependent manner. Pretreatment with 4-diphenylacetoxypiperidinium iodide completely inhibited GSS-induced pacemaker potential depolarizations. Intracellular GDP-β-S inhibited GSS-induced effects, and in the presence of U-73122, GSS-induced effects were inhibited. Also, GSS in the presence of a Ca2+-free solution or thapsigargin did not depolarize pacemaker potentials. However, in the presence of calphostin C, GSS slightly depolarized pacemaker potentials. Furthermore, GSS inhibited both transient receptor potential melastatin7 and Ca2+-activated Cl- channel (anoctamin1) currents. GSS depolarized pacemaker potentials of ICCs via G protein and muscarinic M3 receptor signaling pathways and through internal or external Ca2+-, phospholipase C-, and protein kinase C-dependent and transient receptor potential melastatin 7-, and anoctamin 1-independent pathways. The study shows that GSS may regulate GI tract motility, suggesting that GSS could be a basis for developing novel prokinetic agents for treating GI motility dysfunctions. © 2018 S. Karger AG, Basel.
Tricuspid valve repair for severe tricuspid regurgitation due to pacemaker leads.
Uehara, Kyokun; Minakata, Kenji; Watanabe, Kentaro; Sakaguchi, Hisashi; Yamazaki, Kazuhiro; Ikeda, Tadashi; Sakata, Ryuzo
2016-07-01
Tricuspid valve regurgitation due to pacemaker leads is a well-known complication. Although some reports have suggested that pacemaker leads should be surgically explanted, strongly adhered leads cannot always be removed. The aim of this study was to describe our tricuspid valve repair techniques with pacemaker leads left in situ. Our retrospective study investigated 6 consecutive patients who required tricuspid valve surgery for severe regurgitation induced by pacemaker leads. From the operative findings, we identified 3 patterns of tricuspid valve and pacemaker lead involvement. In 3 patients, the leads were caught in the chordae, in 2 patients, tricuspid regurgitation was caused by lead impingement on the septal leaflet, and in 3 patients, tricuspid valve leaflets had been perforated by the pacemaker leads. During surgery, all leads were left in situ after being separated from the leaflet or valvular apparatus. In addition, suture annuloplasty was performed for annular dilatation in all cases. In one patient, the lead was reaffixed to the annulus after the posterior leaflet was cut back towards the annulus, and the leaflet was then closed. There was one hospital death due to sepsis. The degree of tricuspid regurgitation was trivial in all surviving patients at discharge. During a mean follow-up of 21 months, one patient died from pneumonia 20 months after tricuspid valve repair. In patients undergoing tricuspid valve surgery due to severe tricuspid regurgitation caused by pacemaker leads, the leads can be left in situ after proper repair with annuloplasty. © The Author(s) 2016.
Outcome and management of pacemaker-induced superior vena cava syndrome.
Fu, Hai-Xia; Huang, Xin-Miao; Zhong, Li; Osborn, Michael J; Bjarnason, Haraldur; Mulpuru, Siva; Zhao, Xian-Xian; Friedman, Paul A; Cha, Yong-Mei
2014-11-01
We aimed to determine the long-term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker-induced superior vena cava (SVC) syndrome. The study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker-induced SVC syndrome. Demographic, clinical, and follow-up characteristics of those patients were collected from electronic medical records. Six cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual-chamber pacemakers, with a mean 11-year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21-year-old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow-up duration was 48 months (range, 10-100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence. Percutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker-induced SVC syndrome, although some cases may require repeat intervention. ©2014 Wiley Periodicals, Inc.
Neuropeptide Secreted from a Pacemaker Activates Neurons to Control a Rhythmic Behavior
Wang, Han; Girskis, Kelly; Janssen, Tom; Chan, Jason P.; Dasgupta, Krishnakali; Knowles, James A.; Schoofs, Liliane; Sieburth, Derek
2013-01-01
Summary Background Rhythmic behaviors are driven by endogenous biological clocks in pacemakers, which must reliably transmit timing information to target tissues that execute rhythmic outputs. During the defecation motor program in C. elegans, calcium oscillations in the pacemaker (intestine), which occur about every 50 seconds, trigger rhythmic enteric muscle contractions through downstream GABAergic neurons that innervate enteric muscles. However, the identity of the timing signal released by the pacemaker and the mechanism underlying the delivery of timing information to the GABAergic neurons are unknown. Results Here we show that a neuropeptide-like protein (NLP-40) released by the pacemaker triggers a single rapid calcium transient in the GABAergic neurons during each defecation cycle. We find that mutants lacking nlp-40 have normal pacemaker function, but lack enteric muscle contractions. NLP-40 undergoes calcium-dependent release that is mediated by the calcium sensor, SNT-2/synaptotagmin. We identify AEX-2, the G protein-coupled receptor on the GABAergic neurons, as the receptor of NLP-40. Functional calcium imaging reveals that NLP-40 and AEX-2/GPCR are both necessary for rhythmic activation of these neurons. Furthermore, acute application of synthetic NLP-40-derived peptide depolarizes the GABAergic neurons in vivo. Conclusions Our results show that NLP-40 carries the timing information from the pacemaker via calcium-dependent release and delivers it to the GABAergic neurons by instructing their activation. Thus, we propose that rhythmic release of neuropeptides can deliver temporal information from pacemakers to downstream neurons to execute rhythmic behaviors. PMID:23583549
Andalam, Sidharta; Ramanna, Harshavardhan; Malik, Avinash; Roop, Parthasarathi; Patel, Nitish; Trew, Mark L
2016-08-01
Virtual heart models have been proposed for closed loop validation of safety-critical embedded medical devices, such as pacemakers. These models must react in real-time to off-the-shelf medical devices. Real-time performance can be obtained by implementing models in computer hardware, and methods of compiling classes of Hybrid Automata (HA) onto FPGA have been developed. Models of ventricular cardiac cell electrophysiology have been described using HA which capture the complex nonlinear behavior of biological systems. However, many models that have been used for closed-loop validation of pacemakers are highly abstract and do not capture important characteristics of the dynamic rate response. We developed a new HA model of cardiac cells which captures dynamic behavior and we implemented the model in hardware. This potentially enables modeling the heart with over 1 million dynamic cells, making the approach ideal for closed loop testing of medical devices.
Pacemakers in large arrays of oscillators with nonlocal coupling
NASA Astrophysics Data System (ADS)
Jaramillo, Gabriela; Scheel, Arnd
2016-02-01
We model pacemaker effects of an algebraically localized heterogeneity in a 1 dimensional array of oscillators with nonlocal coupling. We assume the oscillators obey simple phase dynamics and that the array is large enough so that it can be approximated by a continuous nonlocal evolution equation. We concentrate on the case of heterogeneities with positive average and show that steady solutions to the nonlocal problem exist. In particular, we show that these heterogeneities act as a wave source. This effect is not possible in 3 dimensional systems, such as the complex Ginzburg-Landau equation, where the wavenumber of weak sources decays at infinity. To obtain our results we use a series of isomorphisms to relate the nonlocal problem to the viscous eikonal equation. We then use Fredholm properties of the Laplace operator in Kondratiev spaces to obtain solutions to the eikonal equation, and by extension to the nonlocal problem.
Epigenetics of sleep and chronobiology.
Qureshi, Irfan A; Mehler, Mark F
2014-03-01
The circadian clock choreographs fundamental biological rhythms. This system is comprised of the master circadian pacemaker in the suprachiasmatic nucleus and associated pacemakers in other tissues that coordinate complex physiological processes and behaviors, such as sleep, feeding, and metabolism. The molecular circuitry that underlies these clocks and orchestrates circadian gene expression has been the focus of intensive investigation, and it is becoming clear that epigenetic factors are highly integrated into these networks. In this review, we draw attention to the fundamental roles played by epigenetic mechanisms in transcriptional and post-transcriptional regulation within the circadian clock system. We also highlight how alterations in epigenetic factors and mechanisms are being linked with sleep-wake disorders. These observations provide important insights into the pathogenesis and potential treatment of these disorders and implicate epigenetic deregulation in the significant but poorly understood interconnections now emerging between circadian processes and neurodegeneration, metabolic diseases, cancer, and aging.
The Drosophila Circadian Pacemaker Circuit: Pas de Deux or Tarantella?
Sheeba, Vasu; Kaneko, Maki; Sharma, Vijay Kumar; Holmes, Todd C.
2008-01-01
Molecular genetic analysis of the fruit fly Drosophila melanogaster has revolutionized our understanding of the transcription/translation loop mechanisms underlying the circadian molecular oscillator. More recently, Drosophila has been used to understand how different neuronal groups within the circadian pacemaker circuit interact to regulate the overall behavior of the fly in response to daily cyclic environmental cues as well as seasonal changes. Our present understanding of circadian timekeeping at the molecular and circuit level is discussed with a critical evaluation of the strengths and weaknesses of present models. Two models for circadian neural circuits are compared: one that posits that two anatomically distinct oscillators control the synchronization to the two major daily morning and evening transitions, versus a distributed network model that posits that many cell-autonomous oscillators are coordinated in a complex fashion and respond via plastic mechanisms to changes in environmental cues. PMID:18307108
A Novel Way Of Repair Of Insulation Breaks During Pacemaker Generator Replacement
Manzoor Ali, Syed; Iqbal, Khurshid; Tramboo, Nisar A; Lone, Aijaz A; Kaul, Suresh; Kaul, Neelam; Hafiz, Imran
2009-01-01
Minor abrasions can occur while mobilising old lead during pacemaker generator replacement necesittating placement of additional lead adding to the financial burden and junk in heart. We describe a novel way of repair of old pacemaker lead preventing additional lead placement. PMID:19763196