Sample records for audible frequency range

  1. Experimental demonstrations in audible frequency range of band gap tunability and negative refraction in two-dimensional sonic crystal.

    PubMed

    Pichard, Hélène; Richoux, Olivier; Groby, Jean-Philippe

    2012-10-01

    The propagation of audible acoustic waves in two-dimensional square lattice tunable sonic crystals (SC) made of square cross-section infinitely rigid rods embedded in air is investigated experimentally. The band structure is calculated with the plane wave expansion (PWE) method and compared with experimental measurements carried out on a finite extend structure of 200 cm width, 70 cm depth and 15 cm height. The structure is made of square inclusions of 5 cm side with a periodicity of L = 7.5 cm placed inbetween two rigid plates. The existence of tunable complete band gaps in the audible frequency range is demonstrated experimentally by rotating the scatterers around their vertical axis. Negative refraction is then analyzed by use of the anisotropy of the equi-frequency surface (EFS) in the first band and of a finite difference time domain (FDTD) method. Experimental results finally show negative refraction in the audible frequency range.

  2. Apparatus for monitoring X-ray beam alignment

    DOEpatents

    Steinmeyer, Peter A.

    1991-10-08

    A self-contained, hand-held apparatus is provided for minitoring alignment of an X-ray beam in an instrument employing an X-ray source. The apparatus includes a transducer assembly containing a photoresistor for providing a range of electrical signals responsive to a range of X-ray beam intensities from the X-ray beam being aligned. A circuit, powered by a 7.5 VDC power supply and containing an audio frequency pulse generator whose frequency varies with the resistance of the photoresistor, is provided for generating a range of audible sounds. A portion of the audible range corresponds to low X-ray beam intensity. Another portion of the audible range corresponds to high X-ray beam intensity. The transducer assembly may include an a photoresistor, a thin layer of X-ray fluorescent material, and a filter layer transparent to X-rays but opaque to visible light. X-rays from the beam undergoing alignment penetrate the filter layer and excite the layer of fluorescent material. The light emitted from the fluorescent material alters the resistance of the photoresistor which is in the electrical circuit including the audio pulse generator and a speaker. In employing the apparatus, the X-ray beam is aligned to a complete alignment by adjusting the X-ray beam to produce an audible sound of the maximum frequency.

  3. Apparatus for monitoring X-ray beam alignment

    DOEpatents

    Steinmeyer, P.A.

    1991-10-08

    A self-contained, hand-held apparatus is provided for monitoring alignment of an X-ray beam in an instrument employing an X-ray source. The apparatus includes a transducer assembly containing a photoresistor for providing a range of electrical signals responsive to a range of X-ray beam intensities from the X-ray beam being aligned. A circuit, powered by a 7.5 VDC power supply and containing an audio frequency pulse generator whose frequency varies with the resistance of the photoresistor, is provided for generating a range of audible sounds. A portion of the audible range corresponds to low X-ray beam intensity. Another portion of the audible range corresponds to high X-ray beam intensity. The transducer assembly may include an a photoresistor, a thin layer of X-ray fluorescent material, and a filter layer transparent to X-rays but opaque to visible light. X-rays from the beam undergoing alignment penetrate the filter layer and excite the layer of fluorescent material. The light emitted from the fluorescent material alters the resistance of the photoresistor which is in the electrical circuit including the audio pulse generator and a speaker. In employing the apparatus, the X-ray beam is aligned to a complete alignment by adjusting the X-ray beam to produce an audible sound of the maximum frequency. 2 figures.

  4. Dynamic stiffness of chemically and physically ageing rubber vibration isolators in the audible frequency range: Part 2—waveguide solution

    NASA Astrophysics Data System (ADS)

    Kari, Leif

    2017-09-01

    The dynamic stiffness of a chemically and physically ageing rubber vibration isolator in the audible frequency range is modelled as a function of ageing temperature, ageing time, actual temperature, time, frequency and isolator dimension. In particular, the dynamic stiffness for an axially symmetric, homogeneously aged rubber vibration isolator is derived by waveguides where the eigenmodes given by the dispersion relation for an infinite cylinder satisfying traction free radial surface boundary condition are matched to satisfy the displacement boundary conditions at the lateral surface ends of the finite rubber cylinder. The constitutive equations are derived in a companion paper (Part 1). The dynamic stiffness is calculated over the whole audible frequency range 20-20,000 Hz at several physical ageing times for a temperature history starting at thermodynamic equilibrium at +25°C and exposed by a sudden temperature step down to -60°C and at several chemical ageing times at temperature +25°C with simultaneous molecular network scission and reformation. The dynamic stiffness results are displaying a strong frequency dependence at a short physical ageing time, showing stiffness magnitude peaks and troughs, and a strong physical ageing time dependence, showing a large stiffness magnitude increase with the increased physical ageing time, while the peaks and troughs are smoothed out. Likewise, stiffness magnitude peaks and troughs are frequency-shifted with increased chemical ageing time. The developed model is possible to apply for dynamic stiffness prediction of rubber vibration isolator over a broad audible frequency range under realistic environmental condition of chemical ageing, mainly attributed to oxygen exposure from outside and of physical ageing, primarily perceived at low-temperature steps.

  5. Modern prescription theory and application: realistic expectations for speech recognition with hearing AIDS.

    PubMed

    Johnson, Earl E

    2013-01-01

    A major decision at the time of hearing aid fitting and dispensing is the amount of amplification to provide listeners (both adult and pediatric populations) for the appropriate compensation of sensorineural hearing impairment across a range of frequencies (e.g., 160-10000 Hz) and input levels (e.g., 50-75 dB sound pressure level). This article describes modern prescription theory for hearing aids within the context of a risk versus return trade-off and efficient frontier analyses. The expected return of amplification recommendations (i.e., generic prescriptions such as National Acoustic Laboratories-Non-Linear 2, NAL-NL2, and Desired Sensation Level Multiple Input/Output, DSL m[i/o]) for the Speech Intelligibility Index (SII) and high-frequency audibility were traded against a potential risk (i.e., loudness). The modeled performance of each prescription was compared one with another and with the efficient frontier of normal hearing sensitivity (i.e., a reference point for the most return with the least risk). For the pediatric population, NAL-NL2 was more efficient for SII, while DSL m[i/o] was more efficient for high-frequency audibility. For the adult population, NAL-NL2 was more efficient for SII, while the two prescriptions were similar with regard to high-frequency audibility. In terms of absolute return (i.e., not considering the risk of loudness), however, DSL m[i/o] prescribed more outright high-frequency audibility than NAL-NL2 for either aged population, particularly, as hearing loss increased. Given the principles and demonstrated accuracy of desensitization (reduced utility of audibility with increasing hearing loss) observed at the group level, additional high-frequency audibility beyond that of NAL-NL2 is not expected to make further contributions to speech intelligibility (recognition) for the average listener.

  6. Surface response of a viscoelastic medium to subsurface acoustic sources with application to medical diagnosis

    NASA Astrophysics Data System (ADS)

    Royston, Thomas J.; Yazicioglu, Yigit; Loth, Francis

    2003-02-01

    The response at the surface of an isotropic viscoelastic medium to buried fundamental acoustic sources is studied theoretically, computationally and experimentally. Finite and infinitesimal monopole and dipole sources within the low audible frequency range (40-400 Hz) are considered. Analytical and numerical integral solutions that account for compression, shear and surface wave response to the buried sources are formulated and compared with numerical finite element simulations and experimental studies on finite dimension phantom models. It is found that at low audible frequencies, compression and shear wave propagation from point sources can both be significant, with shear wave effects becoming less significant as frequency increases. Additionally, it is shown that simple closed-form analytical approximations based on an infinite medium model agree well with numerically obtained ``exact'' half-space solutions for the frequency range and material of interest in this study. The focus here is on developing a better understanding of how biological soft tissue affects the transmission of vibro-acoustic energy from biological acoustic sources below the skin surface, whose typical spectral content is in the low audible frequency range. Examples include sound radiated from pulmonary, gastro-intestinal and cardiovascular system functions, such as breath sounds, bowel sounds and vascular bruits, respectively.

  7. Frequencies of inaudible high-frequency sounds differentially affect brain activity: positive and negative hypersonic effects.

    PubMed

    Fukushima, Ariko; Yagi, Reiko; Kawai, Norie; Honda, Manabu; Nishina, Emi; Oohashi, Tsutomu

    2014-01-01

    The hypersonic effect is a phenomenon in which sounds containing significant quantities of non-stationary high-frequency components (HFCs) above the human audible range (max. 20 kHz) activate the midbrain and diencephalon and evoke various physiological, psychological and behavioral responses. Yet important issues remain unverified, especially the relationship existing between the frequency of HFCs and the emergence of the hypersonic effect. In this study, to investigate the relationship between the hypersonic effect and HFC frequencies, we divided an HFC (above 16 kHz) of recorded gamelan music into 12 band components and applied them to subjects along with an audible component (below 16 kHz) to observe changes in the alpha2 frequency component (10-13 Hz) of spontaneous EEGs measured from centro-parieto-occipital regions (Alpha-2 EEG), which we previously reported as an index of the hypersonic effect. Our results showed reciprocal directional changes in Alpha-2 EEGs depending on the frequency of the HFCs presented with audible low-frequency component (LFC). When an HFC above approximately 32 kHz was applied, Alpha-2 EEG increased significantly compared to when only audible sound was applied (positive hypersonic effect), while, when an HFC below approximately 32 kHz was applied, the Alpha-2 EEG decreased (negative hypersonic effect). These findings suggest that the emergence of the hypersonic effect depends on the frequencies of inaudible HFC.

  8. Biological Effect of Audible Sound Control on Mung Bean (Vigna radiate) Sprout

    PubMed Central

    Cai, W.; He, H.; Zhu, S.; Wang, N.

    2014-01-01

    Audible sound (20–20000 Hz) widely exists in natural world. However, the interaction between audible sound and the growth of plants is usually neglected in biophysics research. Not much effort has been put forth in studying the relation of plant and audible sound. In this work, the effect of audible sound on germination and growth of mung bean (Vigna radiate) was studied under laboratory condition. Audible sound ranging 1000–1500 Hz, 1500–2000 Hz, and 2000–2500 Hz and intensities [80 dB (A), 90 dB (A), 100 dB (A)] were used to stimulate mung bean for 72 hours. The growth of mung bean was evaluated in terms of mean germination time, total length, and total fresh weight. Experimental results indicated that the sound wave can reduce the germination period of mung bean and the mung bean under treatments of sound with intensity around 90 dB and frequency around 2000 Hz and significant increase in growth. Audible sound treatment can promote the growth of mung bean differently for distinct frequency and intensity. The study provides us with a way to understand the effects and rules of sound field on plant growth and a new way to improve the production of mung bean. PMID:25170517

  9. Dynamic stiffness of chemically and physically ageing rubber vibration isolators in the audible frequency range. Part 1: constitutive equations

    NASA Astrophysics Data System (ADS)

    Kari, Leif

    2017-09-01

    The constitutive equations of chemically and physically ageing rubber in the audible frequency range are modelled as a function of ageing temperature, ageing time, actual temperature, time and frequency. The constitutive equations are derived by assuming nearly incompressible material with elastic spherical response and viscoelastic deviatoric response, using Mittag-Leffler relaxation function of fractional derivative type, the main advantage being the minimum material parameters needed to successfully fit experimental data over a broad frequency range. The material is furthermore assumed essentially entropic and thermo-mechanically simple while using a modified William-Landel-Ferry shift function to take into account temperature dependence and physical ageing, with fractional free volume evolution modelled by a nonlinear, fractional differential equation with relaxation time identical to that of the stress response and related to the fractional free volume by Doolittle equation. Physical ageing is a reversible ageing process, including trapping and freeing of polymer chain ends, polymer chain reorganizations and free volume changes. In contrast, chemical ageing is an irreversible process, mainly attributed to oxygen reaction with polymer network either damaging the network by scission or reformation of new polymer links. The chemical ageing is modelled by inner variables that are determined by inner fractional evolution equations. Finally, the model parameters are fitted to measurements results of natural rubber over a broad audible frequency range, and various parameter studies are performed including comparison with results obtained by ordinary, non-fractional ageing evolution differential equations.

  10. Modern Prescription Theory and Application: Realistic Expectations for Speech Recognition With Hearing Aids

    PubMed Central

    2013-01-01

    A major decision at the time of hearing aid fitting and dispensing is the amount of amplification to provide listeners (both adult and pediatric populations) for the appropriate compensation of sensorineural hearing impairment across a range of frequencies (e.g., 160–10000 Hz) and input levels (e.g., 50–75 dB sound pressure level). This article describes modern prescription theory for hearing aids within the context of a risk versus return trade-off and efficient frontier analyses. The expected return of amplification recommendations (i.e., generic prescriptions such as National Acoustic Laboratories—Non-Linear 2, NAL-NL2, and Desired Sensation Level Multiple Input/Output, DSL m[i/o]) for the Speech Intelligibility Index (SII) and high-frequency audibility were traded against a potential risk (i.e., loudness). The modeled performance of each prescription was compared one with another and with the efficient frontier of normal hearing sensitivity (i.e., a reference point for the most return with the least risk). For the pediatric population, NAL-NL2 was more efficient for SII, while DSL m[i/o] was more efficient for high-frequency audibility. For the adult population, NAL-NL2 was more efficient for SII, while the two prescriptions were similar with regard to high-frequency audibility. In terms of absolute return (i.e., not considering the risk of loudness), however, DSL m[i/o] prescribed more outright high-frequency audibility than NAL-NL2 for either aged population, particularly, as hearing loss increased. Given the principles and demonstrated accuracy of desensitization (reduced utility of audibility with increasing hearing loss) observed at the group level, additional high-frequency audibility beyond that of NAL-NL2 is not expected to make further contributions to speech intelligibility (recognition) for the average listener. PMID:24253361

  11. Territorial black-capped chickadee males respond faster to high- than to low-frequency songs in experimentally elevated noise conditions

    PubMed Central

    Slabbekoorn, Hans; Otter, Ken A.

    2017-01-01

    Low-frequency urban noise can interfere with avian communication through masking. Some species are able to shift the frequency of their vocalizations upwards in noisy conditions, which may reduce the effects of masking. However, results from playback studies investigating whether or not such vocal changes improve audibility in noisy conditions are not clear; the responses of free-ranging individuals to shifted signals are potentially confounded by functional trade-offs between masking-related audibility and frequency-dependent signal quality. Black-capped chickadees (Poecile atricapillus) naturally sing their songs at several different frequencies as they pitch-shift to match conspecifics during song-matching contests. They are also known to switch to higher song frequencies in response to experimental noise exposure. Each male produces both high- and low-frequency songs and absolute frequency is not a signal of aggression or dominance, making this an interesting species in which to test whether higher-frequency songs are more audible than lower-frequency songs in noisy conditions. We conducted playback studies across southern and central British Columbia, Canada, using paired song stimuli (high- vs low-frequency songs, n = 24 pairs) embedded in synthetic background noise created to match typical urban sound profiles. Over the course of each playback, the signal-to-noise ratio of the song stimuli was gradually increased by raising the amplitude of the song stimuli while maintaining background noise at a constant amplitude. We evaluated variation in how quickly and aggressively territorial males reacted to each of the paired stimuli. We found that males responded more quickly to playbacks of high- than low-frequency songs when high-frequency songs were presented first, but not when low-frequency songs were first. This difference may be explained by high-frequency songs being more audible combined with a carry-over effect resulting in slower responses to the second stimulus due to habituation. We observed no difference in overall aggression between stimuli. These results suggest that high-frequency songs may be more audible under noisy conditions. PMID:28462051

  12. Correlation between audible noise and corona current generated by AC corona discharge in time and frequency domains

    NASA Astrophysics Data System (ADS)

    Li, Xuebao; Wang, Jing; Li, Yinfei; Zhang, Qian; Lu, Tiebing; Cui, Xiang

    2018-06-01

    Corona-generated audible noise is induced by the collisions between space charges and air molecules. It has been proven that there is a close correlation between audible noise and corona current from DC corona discharge. Analysis on the correlation between audible noise and corona current can promote the cognition of the generation mechanism of corona discharge. In this paper, time-domain waveforms of AC corona-generated audible noise and corona current are measured simultaneously. The one-to-one relationship between sound pressure pulses and corona current pulses can be found and is used to remove the interferences from background noise. After the interferences are removed, the linear correlated relationships between sound pressure pulse amplitude and corona current pulse amplitude are obtained through statistical analysis. Besides, frequency components at the harmonics of power frequency (50 Hz) can be found both in the frequency spectrums of audible noise and corona current through frequency analysis. Furthermore, the self-correlation relationships between harmonic components below 400 Hz with the 50 Hz component are analyzed for audible noise and corona current and corresponding empirical formulas are proposed to calculate the harmonic components based on the 50 Hz component. Finally, based on the AC corona discharge process and generation mechanism of audible noise and corona current, the correlation between audible noise and corona current in time domain and frequency domain are interpreted qualitatively. Besides, with the aid of analytical expressions of periodic square waves, sound pressure pulses, and corona current pulses, the modulation effects from the AC voltage on the pulse trains are used to interpret the generation of the harmonic components of audible noise and corona current.

  13. Physiological and content considerations for a second low frequency channel for bass management, subwoofers, and low frequency enhancement (LFE)

    NASA Astrophysics Data System (ADS)

    Miller, Robert E. (Robin)

    2005-04-01

    Perception of very low frequencies (VLF) below 125 Hz reproduced by large woofers and subwoofers (SW), encompassing 3 octaves of the 10 regarded as audible, has physiological and content aspects. Large room acoustics and vibrato add VLF fluctuations, modulating audible carrier frequencies to >1 Hz. By convention, sounds below 90 Hz produce no interaural cues useful for spatial perception or localization, therefore bass management redirects the VLF range from main channels to a single (monaural) subwoofer channel, even if to more than one subwoofer. Yet subjects claim they hear a difference between a single subwoofer channel and two (stereo bass). If recordings contain spatial VLF content, is it possible physiologically to perceive interaural time/phase difference (ITD/IPD) between 16 and 125 Hz? To what extent does this perception have a lifelike quality; to what extent is it localization? If a first approximation of localization, would binaural SWs allow a higher crossover frequency (smaller satellite speakers)? Reported research supports the Jeffress model of ITD determination in brain structures, and extending the accepted lower frequency limit of IPD. Meanwhile, uncorrelated very low frequencies exist in all tested multi-channel music and movie content. The audibility, recording, and reproduction of uncorrelated VLF are explored in theory and experiments.

  14. Development of micro-electromechanical system (MEMS) cochlear biomodel

    NASA Astrophysics Data System (ADS)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira

    2015-05-01

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.

  15. Development of micro-electromechanical system (MEMS) cochlear biomodel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. Inmore » this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.« less

  16. Audible acoustics in high-shear wet granulation: application of frequency filtering.

    PubMed

    Hansuld, Erin M; Briens, Lauren; McCann, Joe A B; Sayani, Amyn

    2009-08-13

    Previous work has shown analysis of audible acoustic emissions from high-shear wet granulation has potential as a technique for end-point detection. In this research, audible acoustic emissions (AEs) from three different formulations were studied to further develop this technique as a process analytical technology. Condenser microphones were attached to three different locations on a PMA-10 high-shear granulator (air exhaust, bowl and motor) to target different sound sources. Size, flowability and tablet break load data was collected to support formulator end-point ranges and interpretation of AE analysis. Each formulation had a unique total power spectral density (PSD) profile that was sensitive to granule formation and end-point. Analyzing total PSD in 10 Hz segments identified profiles with reduced run variability and distinct maxima and minima suitable for routine granulation monitoring and end-point control. A partial least squares discriminant analysis method was developed to automate selection of key 10 Hz frequency groups using variable importance to projection. The results support use of frequency refinement as a way forward in the development of acoustic emission analysis for granulation monitoring and end-point control.

  17. The influence of audibility on speech recognition with nonlinear frequency compression for children and adults with hearing loss

    PubMed Central

    McCreery, Ryan W.; Alexander, Joshua; Brennan, Marc A.; Hoover, Brenda; Kopun, Judy; Stelmachowicz, Patricia G.

    2014-01-01

    Objective The primary goal of nonlinear frequency compression (NFC) and other frequency lowering strategies is to increase the audibility of high-frequency sounds that are not otherwise audible with conventional hearing-aid processing due to the degree of hearing loss, limited hearing aid bandwidth or a combination of both factors. The aim of the current study was to compare estimates of speech audibility processed by NFC to improvements in speech recognition for a group of children and adults with high-frequency hearing loss. Design Monosyllabic word recognition was measured in noise for twenty-four adults and twelve children with mild to severe sensorineural hearing loss. Stimuli were amplified based on each listener’s audiogram with conventional processing (CP) with amplitude compression or with NFC and presented under headphones using a software-based hearing aid simulator. A modification of the speech intelligibility index (SII) was used to estimate audibility of information in frequency-lowered bands. The mean improvement in SII was compared to the mean improvement in speech recognition. Results All but two listeners experienced improvements in speech recognition with NFC compared to CP, consistent with the small increase in audibility that was estimated using the modification of the SII. Children and adults had similar improvements in speech recognition with NFC. Conclusion Word recognition with NFC was higher than CP for children and adults with mild to severe hearing loss. The average improvement in speech recognition with NFC (7%) was consistent with the modified SII, which indicated that listeners experienced an increase in audibility with NFC compared to CP. Further studies are necessary to determine if changes in audibility with NFC are related to speech recognition with NFC for listeners with greater degrees of hearing loss, with a greater variety of compression settings, and using auditory training. PMID:24535558

  18. Spectro-temporal characteristics of speech at high frequencies, and the potential for restoration of audibility to people with mild-to-moderate hearing loss.

    PubMed

    Moore, Brian C J; Stone, Michael A; Füllgrabe, Christian; Glasberg, Brian R; Puria, Sunil

    2008-12-01

    It is possible for auditory prostheses to provide amplification for frequencies above 6 kHz. However, most current hearing-aid fitting procedures do not give recommended gains for such high frequencies. This study was intended to provide information that could be useful in quantifying appropriate high-frequency gains, and in establishing the population of hearing-impaired people who might benefit from such amplification. The study had two parts. In the first part, wide-bandwidth recordings of normal conversational speech were obtained from a sample of male and female talkers. The recordings were used to determine the mean spectral shape over a wide frequency range, and to determine the distribution of levels (the speech dynamic range) as a function of center frequency. In the second part, audiometric thresholds were measured for frequencies of 0.125, 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, and 12.5 kHz for both ears of 31 people selected to have mild or moderate cochlear hearing loss. The hearing loss was never greater than 70 dB for any frequency up to 4 kHz. The mean spectrum level of the speech fell progressively with increasing center frequency above about 0.5 kHz. For speech with an overall level of 65 dB SPL, the mean 1/3-octave level was 49 and 37 dB SPL for center frequencies of 1 and 10 kHz, respectively. The dynamic range of the speech was similar for center frequencies of 1 and 10 kHz. The part of the dynamic range below the root-mean-square level was larger than reported in previous studies. The mean audiometric thresholds at high frequencies (10 and 12.5 kHz) were relatively high (69 and 77 dB HL, respectively), even though the mean thresholds for frequencies below 4 kHz were 41 dB HL or better. To partially restore audibility for a hearing loss of 65 dB at 10 kHz would require an effective insertion gain of about 36 dB at 10 kHz. With this gain, audibility could be (partly) restored for 25 of the 62 ears assessed.

  19. Characterization and Impact of Low Frequency Wind Turbine Noise Emissions

    NASA Astrophysics Data System (ADS)

    Finch, James

    Wind turbine noise is a complex issue that requires due diligence to minimize any potential impact on quality of life. This study enhances existing knowledge of wind turbine noise through focused analyses of downwind sound propagation, directionality, and the low frequency component of the noise. Measurements were conducted at four wind speeds according to a design of experiments at incremental distances and angles. Wind turbine noise is shown to be highly directional, while downwind sound propagation is spherical with limited ground absorption. The noise is found to have a significant low frequency component that is largely independent of wind speed over the 20-250 Hz range. The generated low frequency noise is shown to be audible above 40 Hz at the MOE setback distance of 550 m. Infrasound levels exhibit higher dependency on wind speed, but remain below audible levels up to 15 m/s.

  20. Audible and infrasonic noise levels in the cabins of modern agricultural tractors--does the risk of adverse, exposure-dependent effects still exist?

    PubMed

    Bilski, Bartosz

    2013-06-01

    The agricultural tractor is one of the most commonly used vehicles on farms and one of the most prominent sources of noise. This article presents an exemplary assessment of the audible and infrasonic noise levels in the cabins of selected modern wheeled agricultural tractors. Operator-perceived audible and infrasonic noise levels in the cabins were examined for 20 types of modern tractors during typical conditions of work. The tractors had been in use for no longer than 3 years, with rated power between 96 kW and 227 kW, designed and produced by world-renowned companies. Noise level measurements were performed in accordance with PN-EN ISO 9612:2011 (ISO 9612:2009). Audible noise levels (A-weighted) ranged from 62.1 to 87.4 dB-A (average: 68.2 to 83.8 dB-A) for different work tasks. The factors influencing noise levels include performed tasks, soil, weather conditions and the skills of individual drivers. In spectrum analysis, the highest noise levels occurred at frequencies 250 Hz, 1 and 2 kHz. Infrasound noise levels (G-weighted) ranged from 87.3 to 111.3 dB-G. The driver-experienced exposure to infrasound was found to increase significantly when the vehicle was in motion. Average audible noise levels have no potential to adversely affect the hearing organ during tasks performed inside the closed cabins of the analysed modern agricultural tractors. Due to the relatively low audible noise levels inside the cabins of modern agricultural tractors, non-auditory effects are the only adverse symptoms that can develop. Modern agricultural tractors emit considerable infrasonic noise levels. All tractors introduced into the market should be subjected to tests with regard to infrasonic noise levels.

  1. Audibility-based predictions of speech recognition for children and adults with normal hearing.

    PubMed

    McCreery, Ryan W; Stelmachowicz, Patricia G

    2011-12-01

    This study investigated the relationship between audibility and predictions of speech recognition for children and adults with normal hearing. The Speech Intelligibility Index (SII) is used to quantify the audibility of speech signals and can be applied to transfer functions to predict speech recognition scores. Although the SII is used clinically with children, relatively few studies have evaluated SII predictions of children's speech recognition directly. Children have required more audibility than adults to reach maximum levels of speech understanding in previous studies. Furthermore, children may require greater bandwidth than adults for optimal speech understanding, which could influence frequency-importance functions used to calculate the SII. Speech recognition was measured for 116 children and 19 adults with normal hearing. Stimulus bandwidth and background noise level were varied systematically in order to evaluate speech recognition as predicted by the SII and derive frequency-importance functions for children and adults. Results suggested that children required greater audibility to reach the same level of speech understanding as adults. However, differences in performance between adults and children did not vary across frequency bands. © 2011 Acoustical Society of America

  2. Underwater noise from three types of offshore wind turbines: estimation of impact zones for harbor porpoises and harbor seals.

    PubMed

    Tougaard, Jakob; Henriksen, Oluf Damsgaard; Miller, Lee A

    2009-06-01

    Underwater noise was recorded from three different types of wind turbines in Denmark and Sweden (Middelgrunden, Vindeby, and Bockstigen-Valar) during normal operation. Wind turbine noise was only measurable above ambient noise at frequencies below 500 Hz. Total sound pressure level was in the range 109-127 dB re 1 microPa rms, measured at distances between 14 and 20 m from the foundations. The 1/3-octave noise levels were compared with audiograms of harbor seals and harbor porpoises. Maximum 1/3-octave levels were in the range 106-126 dB re 1 microPa rms. Maximum range of audibility was estimated under two extreme assumptions on transmission loss (3 and 9 dB per doubling of distance, respectively). Audibility was low for harbor porpoises extending 20-70 m from the foundation, whereas audibility for harbor seals ranged from less than 100 m to several kilometers. Behavioral reactions of porpoises to the noise appear unlikely except if they are very close to the foundations. However, behavioral reactions from seals cannot be excluded up to distances of a few hundred meters. It is unlikely that the noise reaches dangerous levels at any distance from the turbines and the noise is considered incapable of masking acoustic communication by seals and porpoises.

  3. Audible sound treatment of the microalgae Picochlorum oklahomensis for enhancing biomass productivity.

    PubMed

    Cai, Weiming; Dunford, Nurhan Turgut; Wang, Ning; Zhu, Songming; He, Huinong

    2016-02-01

    It has been reported in the literature that exposure of microalgae cells to audible sound could promote growth. This study examined the effect of sound waves with the frequency of 1100 Hz, 2200 Hz, and 3300 Hz to stimulate the biomass productivity of an Oklahoma native strain, Picochlorum oklahomensis (PO). The effect of the frequency of sound on biomass mass was measured. This study demonstrated that audible sound treatment of the algae cultures at 2200 Hz was the most effective in terms of biomass production and volumetric oil yield. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. The effects of decreased audibility produced by high-pass noise masking on cortical event-related potentials to speech sounds/ba/and/da.

    PubMed

    Martin, B A; Sigal, A; Kurtzberg, D; Stapells, D R

    1997-03-01

    This study investigated the effects of decreased audibility produced by high-pass noise masking on cortical event-related potentials (ERPs) N1, N2, and P3 to the speech sounds /ba/and/da/presented at 65 and 80 dB SPL. Normal-hearing subjects pressed a button in response to the deviant sound in an oddball paradigm. Broadband masking noise was presented at an intensity sufficient to completely mask the response to the 65-dB SPL speech sounds, and subsequently high-pass filtered at 4000, 2000, 1000, 500, and 250 Hz. With high-pass masking noise, pure-tone behavioral thresholds increased by an average of 38 dB at the high-pass cutoff and by 50 dB one octave above the cutoff frequency. Results show that as the cutoff frequency of the high-pass masker was lowered, ERP latencies to speech sounds increased and amplitudes decreased. The cutoff frequency where these changes first occurred and the rate of the change differed for N1 compared to N2, P3, and the behavioral measures. N1 showed gradual changes as the masker cutoff frequency was lowered. N2, P3, and behavioral measures showed marked changes below a masker cutoff of 2000 Hz. These results indicate that the decreased audibility resulting from the noise masking affects the various ERP components in a differential manner. N1 is related to the presence of audible stimulus energy, being present whether audible stimuli are discriminable or not. In contrast, N2 and P3 were absent when the stimuli were audible but not discriminable (i.e., when the second formant transitions were masked), reflecting stimulus discrimination. These data have implications regarding the effects of decreased audibility on cortical processing of speech sounds and for the study of cortical ERPs in populations with hearing impairment.

  5. Maturation of the auditory system in clinically normal puppies as reflected by the brain stem auditory-evoked potential wave V latency-intensity curve and rarefaction-condensation differential potentials.

    PubMed

    Poncelet, L C; Coppens, A G; Meuris, S I; Deltenre, P F

    2000-11-01

    To evaluate auditory maturation in puppies. Ten clinically normal Beagle puppies. Puppies were examined repeatedly from days 11 to 36 after birth (8 measurements). Click-evoked brain stem auditory-evoked potentials (BAEP) were obtained in response to rarefaction and condensation click stimuli from 90 dB normal hearing level to wave V threshold, using steps of 10 dB. Responses were added, providing an equivalent to alternate polarity clicks, and subtracted, providing the rarefaction-condensation differential potential (RCDP). Steps of 5 dB were used to determine thresholds of RCDP and wave V. Slope of the low-intensity segment of the wave V latency-intensity curve was calculated. The intensity range at which RCDP could not be recorded (ie, pre-RCDP range) was calculated by subtracting the threshold of wave V from threshold of RCDP RESULTS: Slope of the wave V latency-intensity curve low-intensity segment evolved with age, changing from (mean +/- SD) -90.8 +/- 41.6 to -27.8 +/- 4.1 micros/dB. Similar results were obtained from days 23 through 36. The pre-RCDP range diminished as puppies became older, decreasing from 40.0 +/- 7.5 to 20.5 +/- 6.4 dB. Changes in slope of the latency-intensity curve with age suggest enlargement of the audible range of frequencies toward high frequencies up to the third week after birth. Decrease in the pre-RCDP range may indicate an increase of the audible range of frequencies toward low frequencies. Age-related reference values will assist clinicians in detecting hearing loss in puppies.

  6. Health-Based Audible Noise Guidelines Account for Infrasound and Low-Frequency Noise Produced by Wind Turbines

    PubMed Central

    Berger, Robert G.; Ashtiani, Payam; Ollson, Christopher A.; Whitfield Aslund, Melissa; McCallum, Lindsay C.; Leventhall, Geoff; Knopper, Loren D.

    2015-01-01

    Setbacks for wind turbines have been established in many jurisdictions to address potential health concerns associated with audible noise. However, in recent years, it has been suggested that infrasound (IS) and low-frequency noise (LFN) could be responsible for the onset of adverse health effects self-reported by some individuals living in proximity to wind turbines, even when audible noise limits are met. The purpose of this paper was to investigate whether current audible noise-based guidelines for wind turbines account for the protection of human health, given the levels of IS and LFN typically produced by wind turbines. New field measurements of indoor IS and outdoor LFN at locations between 400 and 900 m from the nearest turbine, which were previously underrepresented in the scientific literature, are reported and put into context with existing published works. Our analysis showed that indoor IS levels were below auditory threshold levels while LFN levels at distances >500 m were similar to background LFN levels. A clear contribution to LFN due to wind turbine operation (i.e., measured with turbines on in comparison to with turbines off) was noted at a distance of 480 m. However, this corresponded to an increase in overall audible sound measures as reported in dB(A), supporting the hypothesis that controlling audible sound produced by normally operating wind turbines will also control for LFN. Overall, the available data from this and other studies suggest that health-based audible noise wind turbine siting guidelines provide an effective means to evaluate, monitor, and protect potential receptors from audible noise as well as IS and LFN. PMID:25759808

  7. Health-based audible noise guidelines account for infrasound and low-frequency noise produced by wind turbines.

    PubMed

    Berger, Robert G; Ashtiani, Payam; Ollson, Christopher A; Whitfield Aslund, Melissa; McCallum, Lindsay C; Leventhall, Geoff; Knopper, Loren D

    2015-01-01

    Setbacks for wind turbines have been established in many jurisdictions to address potential health concerns associated with audible noise. However, in recent years, it has been suggested that infrasound (IS) and low-frequency noise (LFN) could be responsible for the onset of adverse health effects self-reported by some individuals living in proximity to wind turbines, even when audible noise limits are met. The purpose of this paper was to investigate whether current audible noise-based guidelines for wind turbines account for the protection of human health, given the levels of IS and LFN typically produced by wind turbines. New field measurements of indoor IS and outdoor LFN at locations between 400 and 900 m from the nearest turbine, which were previously underrepresented in the scientific literature, are reported and put into context with existing published works. Our analysis showed that indoor IS levels were below auditory threshold levels while LFN levels at distances >500 m were similar to background LFN levels. A clear contribution to LFN due to wind turbine operation (i.e., measured with turbines on in comparison to with turbines off) was noted at a distance of 480 m. However, this corresponded to an increase in overall audible sound measures as reported in dB(A), supporting the hypothesis that controlling audible sound produced by normally operating wind turbines will also control for LFN. Overall, the available data from this and other studies suggest that health-based audible noise wind turbine siting guidelines provide an effective means to evaluate, monitor, and protect potential receptors from audible noise as well as IS and LFN.

  8. 76 FR 17613 - Aviation Service Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ...) regarding audio visual warning systems (AVWS). OCAS, Inc. installs such technology under the trademark OCAS... frequencies to activate obstruction lighting and transmit audible warnings to aircraft on a potential... transmit audible warnings to pilots. We seek comment on operational, licensing, eligibility and equipment...

  9. Segmental and Suprasegmental Perception in Children Using Hearing Aids.

    PubMed

    Wenrich, Kaitlyn A; Davidson, Lisa S; Uchanski, Rosalie M

    Suprasegmental perception (perception of stress, intonation, "how something is said" and "who says it") and segmental speech perception (perception of individual phonemes or perception of "what is said") are perceptual abilities that provide the foundation for the development of spoken language and effective communication. While there are numerous studies examining segmental perception in children with hearing aids (HAs), there are far fewer studies examining suprasegmental perception, especially for children with greater degrees of residual hearing. Examining the relation between acoustic hearing thresholds, and both segmental and suprasegmental perception for children with HAs, may ultimately enable better device recommendations (bilateral HAs, bimodal devices [one CI and one HA in opposite ears], bilateral CIs) for a particular degree of residual hearing. Examining both types of speech perception is important because segmental and suprasegmental cues are affected differentially by the type of hearing device(s) used (i.e., cochlear implant [CI] and/or HA). Additionally, suprathreshold measures, such as frequency resolution ability, may partially predict benefit from amplification and may assist audiologists in making hearing device recommendations. The purpose of this study is to explore the relationship between audibility (via hearing thresholds and speech intelligibility indices), and segmental and suprasegmental speech perception for children with HAs. A secondary goal is to explore the relationships among frequency resolution ability (via spectral modulation detection [SMD] measures), segmental and suprasegmental speech perception, and receptive language in these same children. A prospective cross-sectional design. Twenty-three children, ages 4 yr 11 mo to 11 yr 11 mo, participated in the study. Participants were recruited from pediatric clinic populations, oral schools for the deaf, and mainstream schools. Audiological history and hearing device information were collected from participants and their families. Segmental and suprasegmental speech perception, SMD, and receptive vocabulary skills were assessed. Correlations were calculated to examine the significance (p < 0.05) of relations between audibility and outcome measures. Measures of audibility and segmental speech perception are not significantly correlated, while low-frequency pure-tone average (unaided) is significantly correlated with suprasegmental speech perception. SMD is significantly correlated with all measures (measures of audibility, segmental and suprasegmental perception and vocabulary). Lastly, although age is not significantly correlated with measures of audibility, it is significantly correlated with all other outcome measures. The absence of a significant correlation between audibility and segmental speech perception might be attributed to overall audibility being maximized through well-fit HAs. The significant correlation between low-frequency unaided audibility and suprasegmental measures is likely due to the strong, predominantly low-frequency nature of suprasegmental acoustic properties. Frequency resolution ability, via SMD performance, is significantly correlated with all outcomes and requires further investigation; its significant correlation with vocabulary suggests that linguistic ability may be partially related to frequency resolution ability. Last, all of the outcome measures are significantly correlated with age, suggestive of developmental effects. American Academy of Audiology

  10. Nonlinear frequency compression: effects on sound quality ratings of speech and music.

    PubMed

    Parsa, Vijay; Scollie, Susan; Glista, Danielle; Seelisch, Andreas

    2013-03-01

    Frequency lowering technologies offer an alternative amplification solution for severe to profound high frequency hearing losses. While frequency lowering technologies may improve audibility of high frequency sounds, the very nature of this processing can affect the perceived sound quality. This article reports the results from two studies that investigated the impact of a nonlinear frequency compression (NFC) algorithm on perceived sound quality. In the first study, the cutoff frequency and compression ratio parameters of the NFC algorithm were varied, and their effect on the speech quality was measured subjectively with 12 normal hearing adults, 12 normal hearing children, 13 hearing impaired adults, and 9 hearing impaired children. In the second study, 12 normal hearing and 8 hearing impaired adult listeners rated the quality of speech in quiet, speech in noise, and music after processing with a different set of NFC parameters. Results showed that the cutoff frequency parameter had more impact on sound quality ratings than the compression ratio, and that the hearing impaired adults were more tolerant to increased frequency compression than normal hearing adults. No statistically significant differences were found in the sound quality ratings of speech-in-noise and music stimuli processed through various NFC settings by hearing impaired listeners. These findings suggest that there may be an acceptable range of NFC settings for hearing impaired individuals where sound quality is not adversely affected. These results may assist an Audiologist in clinical NFC hearing aid fittings for achieving a balance between high frequency audibility and sound quality.

  11. Silent emergency alarm system for schools and the like

    NASA Technical Reports Server (NTRS)

    Read, W. S.; Roberts, V. W. (Inventor)

    1973-01-01

    An emergency alert system is described. In a school each classroom (or other area) is instrumented with a hidden microphone and receiver tuned to a non-audible frequency. The receivers' outputs are connected to a central display unit in the school's administrative office. Each instructor is provided with a small concealable transmitter which, when hand activated by the instructor upon the occurrance of any emergency, generates a non-audible signal at the receiver's tuned frequency.

  12. Ultrasonic airborne insertion loss measurements at normal incidence (L).

    PubMed

    Farley, Jayrin; Anderson, Brian E

    2010-12-01

    Transmission loss and insertion loss measurements of building materials at audible frequencies are commonly made using plane wave tubes or as a panel between reverberant rooms. These measurements provide information for noise isolation control in architectural acoustics and in product development. Airborne ultrasonic sound transmission through common building materials has not been fully explored. Technologies and products that utilize ultrasonic frequencies are becoming increasingly more common, hence the need to conduct such measurements. This letter presents preliminary measurements of the ultrasonic insertion loss levels for common building materials over a frequency range of 28-90 kHz using continuous-wave excitation.

  13. Infra-sound cancellation and mitigation in wind turbines

    NASA Astrophysics Data System (ADS)

    Boretti, Albert; Ordys, Andrew; Al Zubaidy, Sarim

    2018-03-01

    The infra-sound spectra recorded inside homes located even several kilometres far from wind turbine installations is characterized by large pressure fluctuation in the low frequency range. There is a significant body of literature suggesting inaudible sounds at low frequency are sensed by humans and affect the wellbeing through different mechanisms. These mechanisms include amplitude modulation of heard sounds, stimulating subconscious pathways, causing endolymphatic hydrops, and possibly potentiating noise-induced hearing loss. We suggest the study of infra-sound active cancellation and mitigation to address the low frequency noise issues. Loudspeakers generate pressure wave components of same amplitude and frequency but opposite phase of the recorded infra sound. They also produce pressure wave components within the audible range reducing the perception of the infra-sound to minimize the sensing of the residual infra sound.

  14. 200 kHz Commercial Sonar Systems Generate Lower Frequency Side Lobes Audible to Some Marine Mammals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Zhiqun; Southall, Brandon; Carlson, Thomas J.

    2014-04-15

    The spectral properties of pulses transmitted by three commercially available 200 kHz echo sounders were measured to assess the possibility that sound energy in below the center (carrier) frequency might be heard by marine mammals. The study found that all three sounders generated sound at frequencies below the center frequency and within the hearing range of some marine mammals and that this sound was likely detectable by the animals over limited ranges. However, at standard operating source levels for the sounders, the sound below the center frequency was well below potentially harmful levels. It was concluded that the sounds generatedmore » by the sounders could affect the behavior of marine mammals within fairly close proximity to the sources and that that the blanket exclusion of echo sounders from environmental impact analysis based solely on the center frequency output in relation to the range of marine mammal hearing should be reconsidered.« less

  15. 33 CFR 86.05 - Sound signal intensity and range of audibility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Sound signal intensity and range... HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Whistles § 86.05 Sound signal intensity and range of audibility. A whistle on a vessel shall provide, in the...

  16. 33 CFR 86.05 - Sound signal intensity and range of audibility.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Sound signal intensity and range... HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Whistles § 86.05 Sound signal intensity and range of audibility. A whistle on a vessel shall provide, in the...

  17. 33 CFR 86.05 - Sound signal intensity and range of audibility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Sound signal intensity and range... HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Whistles § 86.05 Sound signal intensity and range of audibility. A whistle on a vessel shall provide, in the...

  18. Simulation of Acoustic Noise Generated by an Airbreathing, Beam-Powered Launch Vehicle

    NASA Astrophysics Data System (ADS)

    Kennedy, W. C.; Van Laak, P.; Scarton, H. A.; Myrabo, L. N.

    2005-04-01

    A simple acoustic model is developed for predicting the noise signature vs. power level for advanced laser-propelled lightcraft — capable of single-stage flights into low Earth orbit. This model predicts the noise levels generated by a pulsed detonation engine (PDE) during the initial lift-off and acceleration phase, for two representative `tractor-beam' lightcraft designs: a 1-place `Mercury' vehicle (2.5-m diameter, 900-kg); and a larger 5-place `Apollo' vehicle (5-m diameter, 5555-kg) — both the subject of an earlier study. The use of digital techniques to simulate the expected PDE noise signature is discussed, and three examples of fly-by noise signatures are presented. The reduction, or complete elimination of perceptible noise from such engines, can be accomplished by shifting the pulse frequency into the supra-audible or sub-audible range.

  19. Hear it, See it, Explore it: Visualizations and Sonifications of Seismic Signals

    NASA Astrophysics Data System (ADS)

    Fisher, M.; Peng, Z.; Simpson, D. W.; Kilb, D. L.

    2010-12-01

    Sonification of seismic data is an innovative way to represent seismic data in the audible range (Simpson, 2005). Seismic waves with different frequency and temporal characteristics, such as those from teleseismic earthquakes, deep “non-volcanic” tremor and local earthquakes, can be easily discriminated when time-compressed to the audio range. Hence, sonification is particularly useful for presenting complicated seismic signals with multiple sources, such as aftershocks within the coda of large earthquakes, and remote triggering of earthquakes and tremor by large teleseismic earthquakes. Previous studies mostly focused on converting the seismic data into audible files by simple time compression or frequency modulation (Simpson et al., 2009). Here we generate animations of the seismic data together with the sounds. We first read seismic data in the SAC format into Matlab, and generate a sequence of image files and an associated WAV sound file. Next, we use a third party video editor, such as the QuickTime Pro, to combine the image sequences and the sound file into an animation. We have applied this simple procedure to generate animations of remotely triggered earthquakes, tremor and low-frequency earthquakes in California, and mainshock-aftershock sequences in Japan and California. These animations clearly demonstrate the interactions of earthquake sequences and the richness of the seismic data. The tool developed in this study can be easily adapted for use in other research applications and to create sonification/animation of seismic data for education and outreach purpose.

  20. Hush House-induced vibrations at the Arkansas Air National Guard Facility, Fort Smith, Arkansas. Environmental research papers, 1 October 1986-30 September 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Battis, J.C.

    1987-11-13

    The T-10 jet engine ground run-up noise suppressor, or Hush House, was designed to reduce the audible effects of jet engine testing on the surrounding community. At least in part, the noise-suppression characteristics of the Hush House are achieved by the transfer of energy from the audible (> 20 Hz) to the infrasonic range (<20 Hz). At some sites these lower-frequency emissions have had deleterious effects on the vibro-acoustic environment of nearby buildings. This report describes a case study on this problem and demonstrates that existing siting criteria for the Hush House are inadequate; in one case being too stringentmore » and in another case too lax. An acoustic-emissions model for the Hush House is proposed based on multiple jet-type sources.« less

  1. Emergency Vehicle Siren Noise Effectiveness

    NASA Astrophysics Data System (ADS)

    D'Angela, Peter

    Navigating safely through traffic, while responding to an emergency, is often a challenge for emergency responders. To help alert other motorists, these responders use emergency lights and/or sirens. However, the former is useful only if within clear visual range of the other drivers. This shortcoming puts a greater emphasis on the importance of the audible emergency siren, which has its own shortcomings. This study considered several emergency siren systems with the goal to determine the most effective siren system(s) based on several criteria. Multiple experimental measurements and subjective analysis using jury testing using an NVH driving simulator were performed. It was found that the traditional mechanical siren was the most effective audible warning device; however, with significantly reduced electrical power requirements, the low frequency Rumbler siren, in conjunction with a more conventional electronic Yelp siren, was the preferred option. Recommendations for future work are also given.

  2. Effects of Proof Mass Geometry on Piezoelectric Vibration Energy Harvesters

    PubMed Central

    Gratuze, Mathieu; Elsayed, Mohannad Y.

    2018-01-01

    Piezoelectric energy harvesters have proven to have the potential to be a power source in a wide range of applications. As the harvester dimensions scale down, the resonance frequencies of these devices increase drastically. Proof masses are essential in micro-scale devices in order to decrease the resonance frequency and increase the strain along the beam to increase the output power. In this work, the effects of proof mass geometry on piezoelectric energy harvesters are studied. Different geometrical dimension ratios have significant impact on the resonance frequency, e.g., beam to mass lengths, and beam to mass widths. A piezoelectric energy harvester has been fabricated and tested operating at a frequency of about 4 kHz within the audible range. The responses of various prototypes were studied, and an optimized T-shaped piezoelectric vibration energy harvester design is presented for improved performance. PMID:29772706

  3. Effects of Proof Mass Geometry on Piezoelectric Vibration Energy Harvesters.

    PubMed

    Alameh, Abdul Hafiz; Gratuze, Mathieu; Elsayed, Mohannad Y; Nabki, Frederic

    2018-05-16

    Piezoelectric energy harvesters have proven to have the potential to be a power source in a wide range of applications. As the harvester dimensions scale down, the resonance frequencies of these devices increase drastically. Proof masses are essential in micro-scale devices in order to decrease the resonance frequency and increase the strain along the beam to increase the output power. In this work, the effects of proof mass geometry on piezoelectric energy harvesters are studied. Different geometrical dimension ratios have significant impact on the resonance frequency, e.g., beam to mass lengths, and beam to mass widths. A piezoelectric energy harvester has been fabricated and tested operating at a frequency of about 4 kHz within the audible range. The responses of various prototypes were studied, and an optimized T-shaped piezoelectric vibration energy harvester design is presented for improved performance.

  4. Intelligent Weather Agent

    NASA Technical Reports Server (NTRS)

    Spirkovska, Liljana (Inventor)

    2006-01-01

    Method and system for automatically displaying, visually and/or audibly and/or by an audible alarm signal, relevant weather data for an identified aircraft pilot, when each of a selected subset of measured or estimated aviation situation parameters, corresponding to a given aviation situation, has a value lying in a selected range. Each range for a particular pilot may be a default range, may be entered by the pilot and/or may be automatically determined from experience and may be subsequently edited by the pilot to change a range and to add or delete parameters describing a situation for which a display should be provided. The pilot can also verbally activate an audible display or visual display of selected information by verbal entry of a first command or a second command, respectively, that specifies the information required.

  5. 200 kHz Commercial Sonar Systems Generate Lower Frequency Side Lobes Audible to Some Marine Mammals

    PubMed Central

    Deng, Z. Daniel; Southall, Brandon L.; Carlson, Thomas J.; Xu, Jinshan; Martinez, Jayson J.; Weiland, Mark A.; Ingraham, John M.

    2014-01-01

    The spectral properties of pulses transmitted by three commercially available 200 kHz echo sounders were measured to assess the possibility that marine mammals might hear sound energy below the center (carrier) frequency that may be generated by transmitting short rectangular pulses. All three sounders were found to generate sound at frequencies below the center frequency and within the hearing range of some marine mammals, e.g. killer whales, false killer whales, beluga whales, Atlantic bottlenose dolphins, harbor porpoises, and others. The frequencies of these sub-harmonic sounds ranged from 90 to 130 kHz. These sounds were likely detectable by the animals over distances up to several hundred meters but were well below potentially harmful levels. The sounds generated by the sounders could potentially affect the behavior of marine mammals within fairly close proximity to the sources and therefore the exclusion of echo sounders from environmental impact analysis based solely on the center frequency output in relation to the range of marine mammal hearing should be reconsidered. PMID:24736608

  6. Correlated evolution between hearing sensitivity and social calls in bats

    PubMed Central

    Bohn, Kirsten M; Moss, Cynthia F; Wilkinson, Gerald S

    2006-01-01

    Echolocating bats are auditory specialists, with exquisite hearing that spans several octaves. In the ultrasonic range, bat audiograms typically show highest sensitivity in the spectral region of their species-specific echolocation calls. Well-developed hearing in the audible range has been commonly attributed to a need to detect sounds produced by prey. However, bat pups often emit isolation calls with low-frequency components that facilitate mother–young reunions. In this study, we examine whether low-frequency hearing in bats exhibits correlated evolution with (i) body size; (ii) high-frequency hearing sensitivity or (iii) pup isolation call frequency. Using published audiograms, we found that low-frequency hearing sensitivity is not dependent on body size but is related to high-frequency hearing. After controlling for high-frequency hearing, we found that low-frequency hearing exhibits correlated evolution with isolation call frequency. We infer that detection and discrimination of isolation calls have favoured enhanced low-frequency hearing because accurate parental investment is critical: bats have low reproductive rates, non-volant altricial young and must often identify their pups within large crèches. PMID:17148288

  7. Sound Generation by Aircraft Wake Vortices

    NASA Technical Reports Server (NTRS)

    Hardin, Jay C.; Wang, Frank Y.

    2003-01-01

    This report provides an extensive analysis of potential wake vortex noise sources that might be utilized to aid in their tracking. Several possible mechanisms of aircraft vortex sound generation are examined on the basis of discrete vortex dynamic models and characteristic acoustic signatures calculated by application of vortex sound theory. It is shown that the most robust mechanisms result in very low frequency infrasound. An instability of the vortex core structure is discussed and shown to be a possible mechanism for generating higher frequency sound bordering the audible frequency range. However, the frequencies produced are still low and cannot explain the reasonably high-pitched sound that has occasionally been observed experimentally. Since the robust mechanisms appear to generate only very low frequency sound, infrasonic tracking of the vortices may be warranted.

  8. A numerical model of acoustic wave caused by a single positive corona source

    NASA Astrophysics Data System (ADS)

    Zhang, Bo; Li, Zhen; He, Jinliang

    2017-10-01

    Audible noise accompanies corona discharge, which is one of the most important electromagnetic environment issues of high voltage transmission lines. Most of the studies on the audible noise generated by corona discharge focused on statistical analysis of the experimental results and a series of empirical formulas were derived to predict the audible noise. However, few of them interpreted the generating mechanism of the audible noise. Sound wave in the air is actually the fluctuation of the air, which lead to the hypothesis that the sound wave is generated by the interaction of the charged particles and the air molecules in the discharge progress. To validate this hypothesis, experiments were carried out in this paper to study the relationship between the audible noise and the corona current, including the correlation both in time domain and in frequency domain. Based on the experimental results, the fluid equations of the particles in the air were introduced to study the interactions among the electrons, ions, and neutral molecules in the discharge, and a numerical model for the amplitude of corona acoustic emission was developed and validated.

  9. A priori mesh grading for the numerical calculation of the head-related transfer functions

    PubMed Central

    Ziegelwanger, Harald; Kreuzer, Wolfgang; Majdak, Piotr

    2017-01-01

    Head-related transfer functions (HRTFs) describe the directional filtering of the incoming sound caused by the morphology of a listener’s head and pinnae. When an accurate model of a listener’s morphology exists, HRTFs can be calculated numerically with the boundary element method (BEM). However, the general recommendation to model the head and pinnae with at least six elements per wavelength renders the BEM as a time-consuming procedure when calculating HRTFs for the full audible frequency range. In this study, a mesh preprocessing algorithm is proposed, viz., a priori mesh grading, which reduces the computational costs in the HRTF calculation process significantly. The mesh grading algorithm deliberately violates the recommendation of at least six elements per wavelength in certain regions of the head and pinnae and varies the size of elements gradually according to an a priori defined grading function. The evaluation of the algorithm involved HRTFs calculated for various geometric objects including meshes of three human listeners and various grading functions. The numerical accuracy and the predicted sound-localization performance of calculated HRTFs were analyzed. A-priori mesh grading appeared to be suitable for the numerical calculation of HRTFs in the full audible frequency range and outperformed uniform meshes in terms of numerical errors, perception based predictions of sound-localization performance, and computational costs. PMID:28239186

  10. Cell type-specific suppression of mechanosensitive genes by audible sound stimulation.

    PubMed

    Kumeta, Masahiro; Takahashi, Daiji; Takeyasu, Kunio; Yoshimura, Shige H

    2018-01-01

    Audible sound is a ubiquitous environmental factor in nature that transmits oscillatory compressional pressure through the substances. To investigate the property of the sound as a mechanical stimulus for cells, an experimental system was set up using 94.0 dB sound which transmits approximately 10 mPa pressure to the cultured cells. Based on research on mechanotransduction and ultrasound effects on cells, gene responses to the audible sound stimulation were analyzed by varying several sound parameters: frequency, wave form, composition, and exposure time. Real-time quantitative PCR analyses revealed a distinct suppressive effect for several mechanosensitive and ultrasound-sensitive genes that were triggered by sounds. The effect was clearly observed in a wave form- and pressure level-specific manner, rather than the frequency, and persisted for several hours. At least two mechanisms are likely to be involved in this sound response: transcriptional control and RNA degradation. ST2 stromal cells and C2C12 myoblasts exhibited a robust response, whereas NIH3T3 cells were partially and NB2a neuroblastoma cells were completely insensitive, suggesting a cell type-specific response to sound. These findings reveal a cell-level systematic response to audible sound and uncover novel relationships between life and sound.

  11. Cell type-specific suppression of mechanosensitive genes by audible sound stimulation

    PubMed Central

    Takahashi, Daiji; Takeyasu, Kunio; Yoshimura, Shige H.

    2018-01-01

    Audible sound is a ubiquitous environmental factor in nature that transmits oscillatory compressional pressure through the substances. To investigate the property of the sound as a mechanical stimulus for cells, an experimental system was set up using 94.0 dB sound which transmits approximately 10 mPa pressure to the cultured cells. Based on research on mechanotransduction and ultrasound effects on cells, gene responses to the audible sound stimulation were analyzed by varying several sound parameters: frequency, wave form, composition, and exposure time. Real-time quantitative PCR analyses revealed a distinct suppressive effect for several mechanosensitive and ultrasound-sensitive genes that were triggered by sounds. The effect was clearly observed in a wave form- and pressure level-specific manner, rather than the frequency, and persisted for several hours. At least two mechanisms are likely to be involved in this sound response: transcriptional control and RNA degradation. ST2 stromal cells and C2C12 myoblasts exhibited a robust response, whereas NIH3T3 cells were partially and NB2a neuroblastoma cells were completely insensitive, suggesting a cell type-specific response to sound. These findings reveal a cell-level systematic response to audible sound and uncover novel relationships between life and sound. PMID:29385174

  12. Wideband acoustic records of explosive volcanic eruptions at Stromboli: New insights on the explosive process and the acoustic source

    NASA Astrophysics Data System (ADS)

    Goto, A.; Ripepe, M.; Lacanna, G.

    2014-06-01

    Wideband acoustic waves, both inaudible infrasound (<20 Hz) and audible component (>20 Hz), generated by strombolian eruptions were recorded at 5 kHz and correlated with video images. The high sample rate revealed that in addition to the known initial infrasound, the acoustic signal includes an energetic high-frequency (typically >100 Hz) coda. This audible signal starts before the positive infrasound onset goes negative. We suggest that the infrasonic onset is due to magma doming at the free surface, whereas the immediate high-frequency signal reflects the following explosive discharge flow. During strong gas-rich eruptions, positively skewed shockwave-like components with sharp compression and gradual depression appeared. We suggest that successive bursting of overpressurized small bubbles and the resultant volcanic jets sustain the highly gas-rich explosions and emit the audible sound. When the jet is supersonic, microexplosions of ambient air entrained in the hot jet emit the skewed waveforms.

  13. Audible thunder characteristic and the relation between peak frequency and lightning parameters

    NASA Astrophysics Data System (ADS)

    Yuhua, Ouyang; Ping, Yuan

    2012-02-01

    In recent summers, some natural lightning optical spectra and audible thunder signals were observed. Twelve events on 15 August 2008 are selected as samples since some synchronizing information about them are obtained, such as lightning optical spectra, surface E-field changes, etc. By using digital filter and Fourier transform, thunder frequency spectra in observation location have been calculated. Then the two main propagation effects, finite amplitude propagation and attenuation by air, are calculated. Upon that we take the test thunder frequency spectra and work backward to recalculate the original frequency spectra near generation location. Thunder frequency spectra and the frequency distribution varying with distance are researched. According to the theories on plasma, the channel temperature and electron density are further calculated by transition parameters of lines in lightning optical spectra. Pressure and the average ionization degree of each discharge channel are obtained by using Saha equations, charge conservation equations and particle conservation equations. Moreover, the relationship between the peak frequency of each thunder and channel parameters of the lightning is studied.

  14. Spatial separation benefit for unaided and aided listening

    PubMed Central

    Ahlstrom, Jayne B.; Horwitz, Amy R.; Dubno, Judy R.

    2013-01-01

    Consonant recognition in noise was measured at a fixed signal-to-noise ratio as a function of low-pass-cutoff frequency and noise location in older adults fit with bilateral hearing aids. To quantify age-related differences, spatial benefit was assessed in younger and older adults with normal hearing. Spatial benefit was similar for all groups suggesting that older adults used interaural difference cues to improve speech recognition in noise equivalently to younger adults. Although amplification was sufficient to increase high-frequency audibility with spatial separation, hearing-aid benefit was minimal, suggesting that factors beyond simple audibility may be responsible for limited hearing-aid benefit. PMID:24121648

  15. Development of a Novel Bone Conduction Verification Tool Using a Surface Microphone: Validation With Percutaneous Bone Conduction Users.

    PubMed

    Hodgetts, William; Scott, Dylan; Maas, Patrick; Westover, Lindsey

    2018-03-23

    To determine if a newly-designed, forehead-mounted surface microphone would yield equivalent estimates of audibility when compared to audibility measured with a skull simulator for adult bone conduction users. Data was analyzed using a within subjects, repeated measures design. There were two different sensors (skull simulator and surface microphone) measuring the same hearing aid programmed to the same settings for all subjects. We were looking for equivalent results. Twenty-one adult percutaneous bone conduction users (12 females and 9 males) were recruited for this study. Mean age was 54.32 years with a standard deviation of 14.51 years. Nineteen of the subjects had conductive/mixed hearing loss and two had single-sided deafness. To define audibility, we needed to establish two things: (1) in situ-level thresholds at each audiometric frequency in force (skull simulator) and in sound pressure level (SPL; surface microphone). Next, we measured the responses of the preprogrammed test device in force on the skull simulator and in SPL on the surface mic in response to pink noise at three input levels: 55, 65, and 75 dB SPL. The skull simulator responses were converted to real head force responses by means of an individual real head to coupler difference transform. Subtracting the real head force level thresholds from the real head force output of the test aid yielded the audibility for each audiometric frequency for the skull simulator. Subtracting the SPL thresholds from the surface microphone from the SPL output of the test aid yielded the audibility for each audiometric frequency for the surface microphone. The surface microphone was removed and retested to establish the test-retest reliability of the tool. We ran a 2 (sensor) × 3 (input level) × 10 (frequency) mixed analysis of variance to determine if there were any significant main effects and interactions. There was a significant three-way interaction, so we proceeded to explore our planned comparisons. There were 90 planned comparisons of interest, three at each frequency (3 × 10) for the three input levels (30 × 3). Therefore, to minimize a type 1 error associated with multiple comparisons, we adjusted alpha using the Holm-Bonferroni method. There were five comparisons that yielded significant differences between the skull simulator and surface microphone (test and retest) in the estimation of audibility. However, the mean difference in these effects was small at 3.3 dB. Both sensors yielded equivalent results for the majority of comparisons. Models of bone conduction devices that have intact skin cannot be measured with the skull simulator. This study is the first to present and evaluate a new tool for bone conduction verification. The surface microphone is capable of yielding equivalent audibility measurements as the skull simulator for percutaneous bone conduction users at multiple input levels. This device holds potential for measuring other bone conduction devices (Sentio, BoneBridge, Attract, Soft headband devices) that do not have a percutaneous implant.

  16. Longitudinal predictors of aided speech audibility in infants and children

    PubMed Central

    McCreery, Ryan W.; Walker, Elizabeth A.; Spratford, Meredith; Bentler, Ruth; Holte, Lenore; Roush, Patricia; Oleson, Jacob; Van Buren, John; Moeller, Mary Pat

    2015-01-01

    Objectives Amplification is a core component of early intervention for children who are hard of hearing (CHH), but hearing aids (HAs) have unique effects that may be independent from other components of the early intervention process, such as caregiver training or speech and language intervention. The specific effects of amplification are rarely described in studies of developmental outcomes. The primary purpose of this manuscript is to quantify aided speech audibility during the early childhood years and examine the factors that influence audibility with amplification for children in the Outcomes of Children with Hearing Loss (OCHL) study. Design Participants were 288 children with permanent hearing loss who were followed as part of the OCHL study. All of the children in this analysis had bilateral hearing loss and wore air-conduction behind-the-ear HAs. At every study visit, hearing thresholds were measured using developmentally-appropriate behavioral methods. Data were obtained for a total of 1043 audiometric evaluations across all subjects for the first four study visits. In addition, the aided audibility of speech through the HA was assessed using probe microphone measures. Hearing thresholds and aided audibility were analyzed. Repeated-measures analyses of variance were conducted to determine if patterns of thresholds and aided audibility were significantly different between ears (left vs. right) or across the first four study visits. Furthermore, a cluster analysis was performed based on the aided audibility at entry into the study, aided audibility at the child’s final visit, and change in aided audibility between these two intervals to determine if there were different patterns of longitudinal aided audibility within the sample. Results Eighty-four percent of children in the study had stable audiometric thresholds during the study, defined as threshold changes <10 dB for any single study visit. There were no significant differences in hearing thresholds, aided audibility, or deviation of the HA fitting from prescriptive targets between ears or across test intervals for the first four visits. Approximately 35% of the children in the study had aided audibility that was below the average for the normative range for the Speech Intelligibility Index (SII) based on degree of hearing loss. The cluster analysis of longitudinal aided audibility revealed three distinct groups of children: a group with consistently high aided audibility throughout the study, a group with decreasing audibility during the study, and a group with consistently low aided audibility. Conclusions The current results indicated that approximately 65% of children in the study had adequate aided audibility of speech and stable hearing during the study period. Limited audibility was associated with greater degrees of hearing loss and larger deviations from prescriptive targets. Studies of developmental outcomes will help to determine how aided audibility is necessary to affects developmental outcomes in CHH. PMID:26731156

  17. A Patient-Centered, Provider-Facilitated Approach to the Refinement of Nonlinear Frequency Compression Parameters Based on Subjective Preference Ratings of Amplified Sound Quality.

    PubMed

    Johnson, Earl E; Light, Keri C

    2015-09-01

    To evaluate sound quality preferences of participants wearing hearing aids with different strengths of nonlinear frequency compression (NFC) processing versus no NFC processing. Two analysis methods, one without and one with a qualifier as to the magnitude of preferences, were compared for their percent agreement to differentiate a small difference in perceived sound quality as a result of applied NFC processing. A single-blind design was used with participants unaware of the presence or strength of NFC processing (independent variable). The National Acoustic Laboratories-Nonlinear 2 (NAL-NL2) prescription of amplification was chosen because audibility is intentionally not prescribed in the presence of larger sensorineural hearing loss thresholds. A lack of prescribed audibility, when present, was deemed an objective qualifier for NFC. NFC is known to improve the input bandwidth available to listeners when high-frequency audibility is not otherwise available and increasing strengths of NFC were examined. Experimental condition 3 (EC3) was stronger than the manufacturer default (EC2). More aggressive strengths (e.g., EC4 and EC5), however, were expected to include excessive distortion and even reduce the output bandwidth that had been prescribed as audible by NAL-NL2 (EC1). A total of 14 male Veterans with severe high-frequency sensorineural hearing loss. Participant sound quality preference ratings (dependent variable) without a qualifier as to the magnitude of preference were analyzed based on binomial probability theory, as is traditional with paired comparison data. The ratings with a qualifier as to the magnitude of preference were analyzed based on the nonparametric statistic of the Wilcoxon signed rank test. The binomial probability analysis method identified a sound quality preference as well as the nonparametric probability test method. As the strength of NFC increased, more participants preferred the EC with less NFC. Fourteen of 14 participants showed equal preference between EC1 and EC2 perhaps, in part, because EC2 showed no objective improvement in audibility for six of the 14 participants (42%). Thirteen of the 14 participants showed no preference between NAL-NL2 and EC3, but all participants had an objective improvement in audibility. With more NFC than EC3, more and more participants preferred the other EC with less NFC in the paired comparison. By referencing the recommended sensation levels of amplitude compression (e.g., NAL-NL2) in the ear canal of hearing aid wearers, the targeting of NFC parameters can likely be optimized with respect to improvements in effective audibility that may contribute to speech recognition without adversely impacting sound quality. After targeting of NFC parameters, providers can facilitate decisions about the use of NFC parameters (strengths of processing) via sound quality preference judgments using paired comparisons. American Academy of Audiology.

  18. Photoacoustic Sounds from Meteors.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spalding, Richard E.; Tencer, John; Sweatt, William C.

    2015-03-01

    High-speed photometric observations of meteor fireballs have shown that they often produce high-amplitude light oscillations with frequency components in the kHz range, and in some cases exhibit strong millisecond flares. We built a light source with similar characteristics and illuminated various materials in the laboratory, generating audible sounds. Models suggest that light oscillations and pulses can radiatively heat dielectric materials, which in turn conductively heats the surrounding air on millisecond timescales. The sound waves can be heard if the illuminated material is sufficiently close to the observer’s ears. The mechanism described herein may explain many reports of meteors that appearmore » to be audible while they are concurrently visible in the sky and too far away for sound to have propagated to the observer. This photoacoustic (PA) explanation provides an alternative to electrophonic (EP) sounds hypothesized to arise from electromagnetic coupling of plasma oscillation in the meteor wake to natural antennas in the vicinity of an observer.« less

  19. A Noise Level Prediction Method Based on Electro-Mechanical Frequency Response Function for Capacitors

    PubMed Central

    Zhu, Lingyu; Ji, Shengchang; Shen, Qi; Liu, Yuan; Li, Jinyu; Liu, Hao

    2013-01-01

    The capacitors in high-voltage direct-current (HVDC) converter stations radiate a lot of audible noise which can reach higher than 100 dB. The existing noise level prediction methods are not satisfying enough. In this paper, a new noise level prediction method is proposed based on a frequency response function considering both electrical and mechanical characteristics of capacitors. The electro-mechanical frequency response function (EMFRF) is defined as the frequency domain quotient of the vibration response and the squared capacitor voltage, and it is obtained from impulse current experiment. Under given excitations, the vibration response of the capacitor tank is the product of EMFRF and the square of the given capacitor voltage in frequency domain, and the radiated audible noise is calculated by structure acoustic coupling formulas. The noise level under the same excitations is also measured in laboratory, and the results are compared with the prediction. The comparison proves that the noise prediction method is effective. PMID:24349105

  20. A noise level prediction method based on electro-mechanical frequency response function for capacitors.

    PubMed

    Zhu, Lingyu; Ji, Shengchang; Shen, Qi; Liu, Yuan; Li, Jinyu; Liu, Hao

    2013-01-01

    The capacitors in high-voltage direct-current (HVDC) converter stations radiate a lot of audible noise which can reach higher than 100 dB. The existing noise level prediction methods are not satisfying enough. In this paper, a new noise level prediction method is proposed based on a frequency response function considering both electrical and mechanical characteristics of capacitors. The electro-mechanical frequency response function (EMFRF) is defined as the frequency domain quotient of the vibration response and the squared capacitor voltage, and it is obtained from impulse current experiment. Under given excitations, the vibration response of the capacitor tank is the product of EMFRF and the square of the given capacitor voltage in frequency domain, and the radiated audible noise is calculated by structure acoustic coupling formulas. The noise level under the same excitations is also measured in laboratory, and the results are compared with the prediction. The comparison proves that the noise prediction method is effective.

  1. Optimization of hydrostatic pressure at varied sonication conditions--power density, intensity, very low frequency--for isothermal ultrasonic sludge treatment.

    PubMed

    Delmas, Henri; Le, Ngoc Tuan; Barthe, Laurie; Julcour-Lebigue, Carine

    2015-07-01

    This work aims at investigating for the first time the key sonication (US) parameters: power density (DUS), intensity (IUS), and frequency (FS) - down to audible range, under varied hydrostatic pressure (Ph) and low temperature isothermal conditions (to avoid any thermal effect). The selected application was activated sludge disintegration, a major industrial US process. For a rational approach all comparisons were made at same specific energy input (ES, US energy per solid weight) which is also the relevant economic criterion. The decoupling of power density and intensity was obtained by either changing the sludge volume or most often by changing probe diameter, all other characteristics being unchanged. Comprehensive results were obtained by varying the hydrostatic pressure at given power density and intensity. In all cases marked maxima of sludge disintegration appeared at optimum pressures, which values increased at increasing power intensity and density. Such optimum was expected due to opposite effects of increasing hydrostatic pressure: higher cavitation threshold then smaller and fewer bubbles, but higher temperature and pressure at the end of collapse. In addition the first attempt to lower US frequency down to audible range was very successful: at any operation condition (DUS, IUS, Ph, sludge concentration and type) higher sludge disintegration was obtained at 12 kHz than at 20 kHz. The same values of optimum pressure were observed at 12 and 20 kHz. At same energy consumption the best conditions - obtained at 12 kHz, maximum power density 720 W/L and 3.25 bar - provided about 100% improvement with respect to usual conditions (1 bar, 20 kHz). Important energy savings and equipment size reduction may then be expected. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. The isolation of low frequency impact sounds in hotel construction

    NASA Astrophysics Data System (ADS)

    LoVerde, John J.; Dong, David W.

    2002-11-01

    One of the design challenges in the acoustical design of hotels is reducing low frequency sounds from footfalls occurring on both carpeted and hard-surfaced floors. Research on low frequency impact noise [W. Blazier and R. DuPree, J. Acoust. Soc. Am. 96, 1521-1532 (1994)] resulted in a conclusion that in wood construction low frequency impact sounds were clearly audible and that feasible control methods were not available. The results of numerous FIIC (Field Impact Insulation Class) measurements performed in accordance with ASTM E1007 indicate the lack of correlation between FIIC ratings and the reaction of occupants in the room below. The measurements presented include FIIC ratings and sound pressure level measurements below the ASTM E1007 low frequency limit of 100 Hertz, and reveal that excessive sound levels in the frequency range of 63 to 100 Hertz correlate with occupant complaints. Based upon this history, a tentative criterion for maximum impact sound level in the low frequency range is presented. The results presented of modifying existing constructions to reduce the transmission of impact sounds at low frequencies indicate that there may be practical solutions to this longstanding problem.

  3. An Intrinsically Digital Amplification Scheme for Hearing Aids

    NASA Astrophysics Data System (ADS)

    Blamey, Peter J.; Macfarlane, David S.; Steele, Brenton R.

    2005-12-01

    Results for linear and wide-dynamic range compression were compared with a new 64-channel digital amplification strategy in three separate studies. The new strategy addresses the requirements of the hearing aid user with efficient computations on an open-platform digital signal processor (DSP). The new amplification strategy is not modeled on prior analog strategies like compression and linear amplification, but uses statistical analysis of the signal to optimize the output dynamic range in each frequency band independently. Using the open-platform DSP processor also provided the opportunity for blind trial comparisons of the different processing schemes in BTE and ITE devices of a high commercial standard. The speech perception scores and questionnaire results show that it is possible to provide improved audibility for sound in many narrow frequency bands while simultaneously improving comfort, speech intelligibility in noise, and sound quality.

  4. Application of ultrasound in periodontics: Part I

    PubMed Central

    Bains, Vive K.; Mohan, Ranjana; Bains, Rhythm

    2008-01-01

    Ultrasonic is a branch of acoustics concerned with sound vibrations in frequency ranges above audible level. Ultrasound uses the transmission and reflection of acoustic energy. A pulse is propagated and its reflection is received, both by the transducer. For clinical purposes ultrasound is generated by transducers, which converts electrical energy into ultrasonic waves. This is usually achieved by magnetostriction or piezoelectricity. Primary effects of ultrasound are thermal, mechanical (cavitation and microstreaming), and chemical (sonochemicals). Knowledge of the basic and other secondary effects of ultrasound is essential for the development of techniques of application. PMID:20142941

  5. High intensity tone generation by axisymmetric ring cavities on training projectiles

    NASA Technical Reports Server (NTRS)

    Parthasarathy, S. P.; Cho, Y. I.; Back, L. H.

    1984-01-01

    An experimental investigation has been carried out on the production of high intensity tones by axisymmetric ring cavities. Maximum sound production occurs during a double resonance at Strouhal numbers which depend only on the local flow velocity independent of cavity location. Values of sound pressure of about 115 dB at 1 meter distance can be generated by axisymmetric ring cavities on projectiles moving at a relatively low flight speed equal to 65 m/s. Frequencies in the audible range up to several Kilo Hertz can be generated aeroacoustically.

  6. Experimental characterization of vertical-axis wind turbine noise.

    PubMed

    Pearson, C E; Graham, W R

    2015-01-01

    Vertical-axis wind turbines are wind-energy generators suitable for use in urban environments. Their associated noise thus needs to be characterized and understood. As a first step, this work investigates the relative importance of harmonic and broadband contributions via model-scale wind-tunnel experiments. Cross-spectra from a pair of flush-mounted wall microphones exhibit both components, but further analysis shows that the broadband dominates at frequencies corresponding to the audible range in full-scale operation. This observation has detrimental implications for noise-prediction reliability and hence also for acoustic design optimization.

  7. Assessment of autonomic response by broad-band respiration

    NASA Technical Reports Server (NTRS)

    Berger, R. D.; Saul, J. P.; Cohen, R. J.

    1989-01-01

    We present a technique for introducing broad-band respiratory perturbations so that the response characteristics of the autonomic nervous system can be determined noninvasively over a wide range of physiologically relevant frequencies. A subject's respiratory bandwidth was broadened by breathing on cue to a sequence of audible tones spaced by Poisson intervals. The transfer function between the respiratory input and the resulting instantaneous heart rate was then computed using spectral analysis techniques. Results using this method are comparable to those found using traditional techniques, but are obtained with an economy of data collection.

  8. Reference-Free Assessment of Speech Intelligibility Using Bispectrum of an Auditory Neurogram.

    PubMed

    Hossain, Mohammad E; Jassim, Wissam A; Zilany, Muhammad S A

    2016-01-01

    Sensorineural hearing loss occurs due to damage to the inner and outer hair cells of the peripheral auditory system. Hearing loss can cause decreases in audibility, dynamic range, frequency and temporal resolution of the auditory system, and all of these effects are known to affect speech intelligibility. In this study, a new reference-free speech intelligibility metric is proposed using 2-D neurograms constructed from the output of a computational model of the auditory periphery. The responses of the auditory-nerve fibers with a wide range of characteristic frequencies were simulated to construct neurograms. The features of the neurograms were extracted using third-order statistics referred to as bispectrum. The phase coupling of neurogram bispectrum provides a unique insight for the presence (or deficit) of supra-threshold nonlinearities beyond audibility for listeners with normal hearing (or hearing loss). The speech intelligibility scores predicted by the proposed method were compared to the behavioral scores for listeners with normal hearing and hearing loss both in quiet and under noisy background conditions. The results were also compared to the performance of some existing methods. The predicted results showed a good fit with a small error suggesting that the subjective scores can be estimated reliably using the proposed neural-response-based metric. The proposed metric also had a wide dynamic range, and the predicted scores were well-separated as a function of hearing loss. The proposed metric successfully captures the effects of hearing loss and supra-threshold nonlinearities on speech intelligibility. This metric could be applied to evaluate the performance of various speech-processing algorithms designed for hearing aids and cochlear implants.

  9. Reference-Free Assessment of Speech Intelligibility Using Bispectrum of an Auditory Neurogram

    PubMed Central

    Hossain, Mohammad E.; Jassim, Wissam A.; Zilany, Muhammad S. A.

    2016-01-01

    Sensorineural hearing loss occurs due to damage to the inner and outer hair cells of the peripheral auditory system. Hearing loss can cause decreases in audibility, dynamic range, frequency and temporal resolution of the auditory system, and all of these effects are known to affect speech intelligibility. In this study, a new reference-free speech intelligibility metric is proposed using 2-D neurograms constructed from the output of a computational model of the auditory periphery. The responses of the auditory-nerve fibers with a wide range of characteristic frequencies were simulated to construct neurograms. The features of the neurograms were extracted using third-order statistics referred to as bispectrum. The phase coupling of neurogram bispectrum provides a unique insight for the presence (or deficit) of supra-threshold nonlinearities beyond audibility for listeners with normal hearing (or hearing loss). The speech intelligibility scores predicted by the proposed method were compared to the behavioral scores for listeners with normal hearing and hearing loss both in quiet and under noisy background conditions. The results were also compared to the performance of some existing methods. The predicted results showed a good fit with a small error suggesting that the subjective scores can be estimated reliably using the proposed neural-response-based metric. The proposed metric also had a wide dynamic range, and the predicted scores were well-separated as a function of hearing loss. The proposed metric successfully captures the effects of hearing loss and supra-threshold nonlinearities on speech intelligibility. This metric could be applied to evaluate the performance of various speech-processing algorithms designed for hearing aids and cochlear implants. PMID:26967160

  10. New vibro-acoustic paradigms in biological tissues with application to diagnosis of pulmonary disorders

    NASA Astrophysics Data System (ADS)

    Zhang, Xiangling

    The fundamental objective of the present study is to improve our understanding of audible sound propagation in the pulmonary system and torso. A related applied objective is to assess the feasibility of using audible acoustics for diagnosis of specific pulmonary conditions, such as pneumothorax (PTX). To accomplish these objectives, this study includes theoretical, computational and experimental developments aimed at: (1) better identifying the mechanical dynamic properties of soft biological tissues found in the torso region, (2) investigating the mechanisms of sound attenuation that occur when a PTX is present using greatly simplified theoretical and computational models, and (3) exploring the feasibility and utility of more comprehensive and precise computational finite element models of audible sound propagation in the pulmonary system and torso that would aid in related diagnostic developments. Mechanical material properties of soft biological tissue are studied for the low audible frequency range. The sensitivity to shear viscoelastic material constants of theoretical solutions for radiation impedance and surface wave motion are compared. Theoretical solutions are also compared to experimental measurements and numerical results from finite element analysis. It is found that, while prior theoretical solutions for radiation impedance are accurate, use of such measurements to estimate shear viscoelastic constants is not as precise as the use of surface wave measurements. The feasibility of using audible sound for diagnosis of pneumothorax is studied. Simplified one- and two-dimensional theoretical and numerical models of sound transmission through the pulmonary system and chest region to the chest wall surface are developed to more clearly understand the mechanism of energy loss when a pneumothorax is present, relative to a baseline case. A canine study on which these models are based predicts significant decreases in acoustic transmission strength when a pneumothorax is presented, in qualitative agreement with experimental measurements in dogs. Finally, the feasibility of building three-dimensional computational models is studied based on CT images of human subject or combination of the Horsfield airway model with geometry of other parts approximate from medical illustration. Preliminary results from these models show the same trend of acoustic energy loss when a PTX is present.

  11. Investigating the Feedback Path in a Jet-Surface Resonant Interaction

    NASA Technical Reports Server (NTRS)

    Zaman, Khairul; Fagan, Amy; Bridges, James; Brown, Cliff

    2015-01-01

    A resonant interaction between an 8:1 aspect ratio rectangular jet and flat-plates, placed parallel to the jet, is addressed in this study. For certain relative locations of the plates, the resonance takes place with accompanying audible tones. Even when the tone is not audible the sound pressure level spectra is often marked by conspicuous peaks. The frequencies of the spectral peaks, as functions of the streamwise length of the plate and its relative location to the jet as well as the jet Mach number, are explored in an effort of understand the flow mechanism. It is demonstrated that the tones are not due to a simple feedback between the plates trailing edge and the nozzle exit; the leading edge also comes into play in determining the frequency. An acoustic feedback path, involving diffraction from the leading edge, appears to explain the frequencies of some of the spectral peaks.

  12. An Evaluation of Frequency Transposition for Hearing-Impaired School-Age Children

    ERIC Educational Resources Information Center

    Smith, Jenny; Dann, Marilyn; Brown, P. Margaret

    2009-01-01

    A key objective when fitting hearing aids to children is to maximize the audibility of high frequency speech cues which are critical in the understanding of spoken English. Recent advances in digital signal processing have enabled the development of hearing aids which offer linear frequency transposition as a new way of accessing these important…

  13. Psychoacoustic processing of test signals

    NASA Astrophysics Data System (ADS)

    Kadlec, Frantisek

    2003-10-01

    For the quantitative evaluation of electroacoustic system properties and for psychoacoustic testing it is possible to utilize harmonic signals with fixed frequency, sweeping signals, random signals or their combination. This contribution deals with the design of various test signals with emphasis on audible perception. During the digital generation of signals, some additional undesirable frequency components and noise are produced, which are dependent on signal amplitude and sampling frequency. A mathematical analysis describes the origin of this distortion. By proper selection of signal frequency and amplitude it is possible to minimize those undesirable components. An additional step is to minimize the audible perception of this signal distortion by the application of additional noise (dither). For signals intended for listening tests a dither with triangular or Gaussian probability density function was found to be most effective. Signals modified this way may be further improved by the application of noise shaping, which transposes those undesirable products into frequency regions where they are perceived less, according to psychoacoustic principles. The efficiency of individual processing steps was confirmed both by measurements and by listening tests. [Work supported by the Czech Science Foundation.

  14. What is infrasound?

    PubMed

    Leventhall, Geoff

    2007-01-01

    Definitions of infrasound and low-frequency noise are discussed and the fuzzy boundary between them described. Infrasound, in its popular definition as sound below a frequency of 20 Hz, is clearly audible, the hearing threshold having been measured down to 1.5 Hz. The popular concept that sound below 20 Hz is inaudible is not correct. Sources of infrasound are in the range from very low-frequency atmospheric fluctuations up into the lower audio frequencies. These sources include natural occurrences, industrial installations, low-speed machinery, etc. Investigations of complaints of low-frequency noise often fail to measure any significant noise. This has led some complainants to conjecture that their perception arises from non-acoustic sources, such as electromagnetic radiation. Over the past 40 years, infrasound and low-frequency noise have attracted a great deal of adverse publicity on their effects on health, based mainly on media exaggerations and misunderstandings. A result of this has been that the public takes a one-dimensional view of infrasound, concerned only by its presence, whilst ignoring its low levels.

  15. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials.

    PubMed

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L

    2013-12-01

    The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners who participated in the psychoacoustical experiment. The data indicate differences in N1 and P2 between stimuli with and without interaural phase disparities. However, differences for stimuli with and without coherent masker modulation were only found for P2, i.e., only P2 is sensitive to the increase in audibility, irrespective of the cue that caused the masking release. The amplitude of P2 is consistent with the psychoacoustical finding of an addition of the masking releases when both cues are present. Even though it cannot be concluded where along the auditory pathway the audibility is represented, the P2 component of auditory evoked potentials is a candidate for an objective measure of audibility in the human auditory system. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. 3D simulation of an audible ultrasonic electrolarynx using difference waves.

    PubMed

    Mills, Patrick; Zara, Jason

    2014-01-01

    A total laryngectomy removes the vocal folds which are fundamental in forming voiced sounds that make speech possible. Although implanted prosthetics are commonly used in developed countries, simple handheld vibrating electrolarynxes are still common worldwide. These devices are easy to use but suffer from many drawbacks including dedication of a hand, mechanical sounding voice, and sound leakage. To address some of these drawbacks, we introduce a novel electrolarynx that uses vibro-acoustic interference of dual ultrasonic waves to generate an audible fundamental frequency. A 3D simulation of the principles of the device is presented in this paper.

  17. CAVITATION SOUNDS DURING CERVICOTHORACIC SPINAL MANIPULATION.

    PubMed

    Dunning, James; Mourad, Firas; Zingoni, Andrea; Iorio, Raffaele; Perreault, Thomas; Zacharko, Noah; de Las Peñas, César Fernández; Butts, Raymond; Cleland, Joshua A

    2017-08-01

    No study has previously investigated the side, duration or number of audible cavitation sounds during high-velocity low-amplitude (HVLA) thrust manipulation to the cervicothoracic spine. The primary purpose was to determine which side of the spine cavitates during cervicothoracic junction (CTJ) HVLA thrust manipulation. Secondary aims were to calculate the average number of cavitations, the duration of cervicothoracic thrust manipulation, and the duration of a single cavitation. Quasi-experimental study. Thirty-two patients with upper trapezius myalgia received two cervicothoracic HVLA thrust manipulations targeting the right and left T1-2 articulation, respectively. Two high sampling rate accelerometers were secured bilaterally 25 mm lateral to midline of the T1-2 interspace. For each manipulation, two audio signals were extracted using Short-Time Fourier Transformation (STFT) and singularly processed via spectrogram calculation in order to evaluate the frequency content and number of instantaneous energy bursts of both signals over time for each side of the CTJ. Unilateral cavitation sounds were detected in 53 (91.4%) of 58 cervicothoracic HVLA thrust manipulations and bilateral cavitation sounds were detected in just five (8.6%) of the 58 thrust manipulations; that is, cavitation was significantly (p<0.001) more likely to occur unilaterally than bilaterally. In addition, cavitation was significantly (p<0.0001) more likely to occur on the side contralateral to the clinician's short-lever applicator. The mean number of audible cavitations per manipulation was 4.35 (95% CI 2.88, 5.76). The mean duration of a single manipulation was 60.77 ms (95% CI 28.25, 97.42) and the mean duration of a single audible cavitation was 4.13 ms (95% CI 0.82, 7.46). In addition to single-peak and multi-peak energy bursts, spectrogram analysis also demonstrated high frequency sounds, low frequency sounds, and sounds of multiple frequencies for all 58 manipulations. Cavitation was significantly more likely to occur unilaterally, and on the side contralateral to the short-lever applicator contact, during cervicothoracic HVLA thrust manipulation. Clinicians should expect multiple cavitation sounds when performing HVLA thrust manipulation to the CTJ. Due to the presence of multi-peak energy bursts and sounds of multiple frequencies, the cavitation hypothesis (i.e. intra-articular gas bubble collapse) alone appears unable to explain all of the audible sounds during HVLA thrust manipulation, and the possibility remains that several phenomena may be occurring simultaneously. 2b.

  18. Spatial filtering of audible sound with acoustic landscapes

    NASA Astrophysics Data System (ADS)

    Wang, Shuping; Tao, Jiancheng; Qiu, Xiaojun; Cheng, Jianchun

    2017-07-01

    Acoustic metasurfaces manipulate waves with specially designed structures and achieve properties that natural materials cannot offer. Similar surfaces work in audio frequency range as well and lead to marvelous acoustic phenomena that can be perceived by human ears. Being intrigued by the famous Maoshan Bugle phenomenon, we investigate large scale metasurfaces consisting of periodic steps of sizes comparable to the wavelength of audio frequency in both time and space domains. We propose a theoretical method to calculate the scattered sound field and find that periodic corrugated surfaces work as spatial filters and the frequency selective character can only be observed at the same side as the incident wave. The Maoshan Bugle phenomenon can be well explained with the method. Finally, we demonstrate that the proposed method can be used to design acoustical landscapes, which transform impulsive sound into famous trumpet solos or other melodious sound.

  19. Cortical Auditory Evoked Potentials Reveal Changes in Audibility with Nonlinear Frequency Compression in Hearing Aids for Children: Clinical Implications

    PubMed Central

    Ching, Teresa Y. C.; Zhang, Vicky W.; Hou, Sanna; Van Buynder, Patricia

    2016-01-01

    Hearing loss in children is detected soon after birth via newborn hearing screening. Procedures for early hearing assessment and hearing aid fitting are well established, but methods for evaluating the effectiveness of amplification for young children are limited. One promising approach to validating hearing aid fittings is to measure cortical auditory evoked potentials (CAEPs). This article provides first a brief overview of reports on the use of CAEPs for evaluation of hearing aids. Second, a study that measured CAEPs to evaluate nonlinear frequency compression (NLFC) in hearing aids for 27 children (between 6.1 and 16.8 years old) who have mild to severe hearing loss is reported. There was no significant difference in aided sensation level or the detection of CAEPs for /g/ between NLFC on and off conditions. The activation of NLFC was associated with a significant increase in aided sensation levels for /t/ and /s/. It also was associated with an increase in detection of CAEPs for /t/ and /s/. The findings support the use of CAEPs for checking audibility provided by hearing aids. Based on the current data, a clinical protocol for using CAEPs to validate audibility with amplification is presented. PMID:27587920

  20. [Industrial sound spectrum entailing noise-induced occupational hearing loss in Iasi industry].

    PubMed

    Carp, Cristina Maria; Costinescu, V N

    2011-01-01

    In European Union every day millions of employees are exposed to noise at work and the risk this can entail. this study presents the sound spectrum in Iasi heavy industry: metal foundries industry, punching and embossing of metal sheets, cold and hot metal processing. it was used a type 2 Sound Level Meter (SLM) and the considered value was the average value over 10 test values in 10 consecutive days for each octave band in common audible frequency range. It is obviously that the large values of sound intensities in the most of frequency octave band exceed maximum admissible and legal values. The study reveals the necessity of hardware, medical and managerial measures in order to reduce the occupational noise and to prevent the hearing acuity damage of the workers.

  1. Characterization of St. Lawrence blue whale vocalizations and their correlation with field observations

    NASA Astrophysics Data System (ADS)

    Berchok, Catherine L.

    During four field seasons from 1998--2001, 115 hours of acoustic recordings were made in the presence of the well-studied St. Lawrence population of blue whales. The primary field site for this study was the estuary region of the St. Lawrence River (Quebec, Canada) with most recordings made between mid-August and late October. Effort was concentrated in the daylight hours, although occasionally extending past nightfall. An inexpensive and portable recording system was built that was easy to deploy and provided quality recordings in a variety of sea conditions. It consisted of a calibrated omni-directional hydrophone with a flat (+/-3dB) response from 5Hz to 800Hz; and a surface isolation buoy to minimize the vertical movement of the sensor. During the recording sessions detailed field notes were taken on all blue whales within sight, with individual identities confirmed through photo-identification work between sessions. Notes were also taken on all other species sighted during the recording sessions. Characterization of the more than one-thousand blue whale calls detected during this study revealed that the St. Lawrence repertoire is much more extensive than previously reported. Three infrasonic (<20Hz) and four audible range (30--200Hz) call types were detected in this study, with much time/frequency variation seen within each type. The infrasonic calls were long (5--30s) in duration and arranged into regularly patterned series. These calls were similar in call characteristics and spacing to those detected in the North Atlantic, but had much shorter and more variable patterned series. The audible call types were much shorter (1--4s), and occurred singly or in irregularly spaced clusters, although a special patterning was seen that contained both regular and irregular spaced components. Comparison of the daily, seasonal, and spatial distributions of calling behavior with those of several biological parameters revealed interesting differences between the three call types examined. The trends seen suggest a migratory, reproductive, or foraging context for the infrasonic calls. A closer-range social context is suggested for the audible downsweeps, which have been detected in foraging situations as well as in courtship displays. The audible mixed-pattern call type appears to have a primarily reproductive context.

  2. Elastic and viscoelastic effects in rubber/air acoustic band gap structures: A theoretical and experimental study

    NASA Astrophysics Data System (ADS)

    Merheb, B.; Deymier, P. A.; Jain, M.; Aloshyna-Lesuffleur, M.; Mohanty, S.; Berker, A.; Greger, R. W.

    2008-09-01

    The transmission of acoustic waves through centimeter-scale elastic and viscoelastic two-dimensional silicone rubber/air phononic crystal structures is investigated theoretically and experimentally. We introduce a finite difference time domain method for two-dimensional elastic and viscoelastic composite structures. Elastic fluid-solid phononic crystals composed of a two-dimensional array of cylindrical air inclusions in a solid rubber matrix, as well as an array of rubber cylinders in an air matrix, are shown to behave similarly to fluid-fluid composite structures. These systems exhibit very wide band gaps in their transmission spectra that extend to frequencies in the audible range of the spectrum. This effect is associated with the very low value of the transverse speed of sound in rubber compared to that of the longitudinal polarization. The difference in transmission between elastic and viscoelastic rubber/air crystals results from attenuation of transmission over a very wide frequency range, leaving only narrow passing bands at very low frequencies. These phononic crystals demonstrate the practical design of elastic or viscoelastic solid rubber/air acoustic band gap sound barriers with small dimensions.

  3. Listening Effort and Speech Recognition with Frequency Compression Amplification for Children and Adults with Hearing Loss.

    PubMed

    Brennan, Marc A; Lewis, Dawna; McCreery, Ryan; Kopun, Judy; Alexander, Joshua M

    2017-10-01

    Nonlinear frequency compression (NFC) can improve the audibility of high-frequency sounds by lowering them to a frequency where audibility is better; however, this lowering results in spectral distortion. Consequently, performance is a combination of the effects of increased access to high-frequency sounds and the detrimental effects of spectral distortion. Previous work has demonstrated positive benefits of NFC on speech recognition when NFC is set to improve audibility while minimizing distortion. However, the extent to which NFC impacts listening effort is not well understood, especially for children with sensorineural hearing loss (SNHL). To examine the impact of NFC on recognition and listening effort for speech in adults and children with SNHL. Within-subject, quasi-experimental study. Participants listened to amplified nonsense words that were (1) frequency-lowered using NFC, (2) low-pass filtered at 5 kHz to simulate the restricted bandwidth (RBW) of conventional hearing aid processing, or (3) low-pass filtered at 10 kHz to simulate extended bandwidth (EBW) amplification. Fourteen children (8-16 yr) and 14 adults (19-65 yr) with mild-to-severe SNHL. Participants listened to speech processed by a hearing aid simulator that amplified input signals to fit a prescriptive target fitting procedure. Participants were blinded to the type of processing. Participants' responses to each nonsense word were analyzed for accuracy and verbal-response time (VRT; listening effort). A multivariate analysis of variance and linear mixed model were used to determine the effect of hearing-aid signal processing on nonsense word recognition and VRT. Both children and adults identified the nonsense words and initial consonants better with EBW and NFC than with RBW. The type of processing did not affect the identification of the vowels or final consonants. There was no effect of age on recognition of the nonsense words, initial consonants, medial vowels, or final consonants. VRT did not change significantly with the type of processing or age. Both adults and children demonstrated improved speech recognition with access to the high-frequency sounds in speech. Listening effort as measured by VRT was not affected by access to high-frequency sounds. American Academy of Audiology

  4. Hearing at low and infrasonic frequencies.

    PubMed

    Møller, H; Pedersen, C S

    2004-01-01

    The human perception of sound at frequencies below 200 Hz is reviewed. Knowledge about our perception of this frequency range is important, since much of the sound we are exposed to in our everyday environment contains significant energy in this range. Sound at 20-200 Hz is called low-frequency sound, while for sound below 20 Hz the term infrasound is used. The hearing becomes gradually less sensitive for decreasing frequency, but despite the general understanding that infrasound is inaudible, humans can perceive infrasound, if the level is sufficiently high. The ear is the primary organ for sensing infrasound, but at levels somewhat above the hearing threshold it is possible to feel vibrations in various parts of the body. The threshold of hearing is standardized for frequencies down to 20 Hz, but there is a reasonably good agreement between investigations below this frequency. It is not only the sensitivity but also the perceived character of a sound that changes with decreasing frequency. Pure tones become gradually less continuous, the tonal sensation ceases around 20 Hz, and below 10 Hz it is possible to perceive the single cycles of the sound. A sensation of pressure at the eardrums also occurs. The dynamic range of the auditory system decreases with decreasing frequency. This compression can be seen in the equal-loudness-level contours, and it implies that a slight increase in level can change the perceived loudness from barely audible to loud. Combined with the natural spread in thresholds, it may have the effect that a sound, which is inaudible to some people, may be loud to others. Some investigations give evidence of persons with an extraordinary sensitivity in the low and infrasonic frequency range, but further research is needed in order to confirm and explain this phenomenon.

  5. Maximization of the directivity ratio with the desired audible gain level for broadband design of near field loudspeaker arrays

    NASA Astrophysics Data System (ADS)

    Kim, Daesung; Kim, Kihyun; Wang, Semyung; Lee, Sung Q.; Crocker, Malcolm J.

    2011-11-01

    This paper mainly addresses design methods for near field loudspeaker arrays. These methods have been studied recently since they can be used to realize a personal audio space without the use of headphones. From a practical view point, they can also be used to form a directional sound beam within a short distance from the sources especially using a linear loudspeaker array. In this regard, we re-analyzed the previous near field beamforming methods in order to obtain a comprehensive near field beamforming formulation. Broadband directivity control is proposed for multi-objective optimization, which maximizes the directivity with the desired gain, where both the directivity and the gain are commonly used array performance measures. This method of control aims to form a directive sound beam within a short distance while widening the frequency range of the beamforming. Simulation and experimental results demonstrate that broadband directivity control achieves higher directivity and gain over our whole frequency range of interest compared with previous beamforming methods.

  6. Rovers Eye View of 3 Year Trek on Mars

    NASA Image and Video Library

    2010-06-11

    309 images of the Martian horizon taken during 13-mile journey from Victoria crater to Endeavour crater. Numbers at top left are Martian day numbers (sols). Audio comes from rover accelerometer data adjusted to an audible frequency.

  7. Viscoelastic effect on acoustic band gaps in polymer-fluid composites

    NASA Astrophysics Data System (ADS)

    Merheb, B.; Deymier, P. A.; Muralidharan, K.; Bucay, J.; Jain, M.; Aloshyna-Lesuffleur, M.; Greger, R. W.; Mohanty, S.; Berker, A.

    2009-10-01

    In this paper, we present a theoretical analysis of the propagation of acoustic waves through elastic and viscoelastic two-dimensional phononic crystal structures. Numerical calculations of transmission spectra are conducted by extending the finite-difference-time-domain method to account for linear viscoelastic materials with time-dependent moduli. We study a phononic crystal constituted of a square array of cylindrical air inclusions in a solid viscoelastic matrix. The elastic properties of the solid are those of a silicone rubber. This system exhibits very wide band gaps in its transmission spectrum that extend to frequencies in the audible range of the spectrum. These gaps are characteristic of fluid matrix/air inclusion systems and result from the very large contrast between the longitudinal and transverse speeds of sound in rubber. By treating the matrix as a viscoelastic medium within the standard linear solid (SLS) model, we demonstrate that viscoelasticity impacts the transmission properties of the rubber/air phononic crystal not only by attenuating the transmitted acoustic waves but also by shifting the passing bands frequencies toward lower values. The ranges of frequencies exhibiting attenuation or frequency shift are determined by the value of the relaxation time in the SLS model. We show that viscoelasticity can be used to decrease the frequency of pass bands (and consequently stop bands) in viscoelastic/air phononic crystals.

  8. Exposure to audible and infrasonic noise by modern agricultural tractors operators.

    PubMed

    Bilski, Bartosz

    2013-03-01

    The wheeled agricultural tractor is one of the most prominent sources of noise in agriculture. This paper presents the assessment of the operator's exposure to audible and infrasonic noise in 32 selected modern wheeled agricultural tractors designed and produced by world-renowned companies in normal working conditions. The tractors have been in use for no longer than 4 years, with rated power of 51 kW to up to 228 kW (as per 97/68 EC). Audible and infrasonic noise level measurements and occupational exposure analysis to noise were performed according to ISO 9612:2009 (strategy 1 - task-based measurements). The measurements were made in different typical work conditions inside and outside of tractors cabs. The results indicated that exposure levels to noise perceived by the operators (L(ex,Te) between 62,3 and 84,7 dB-A) and can make a small risk of potential adversely effects on hearing during tasks performed inside the closed cab. It should be remarked that uncertainty interval is wider and in in some conditions can occur transgression of audible noise occupational exposure limits. The measured audible noise levels can potentially develop the non-auditory effects. Analysed tractors emit considerable infrasonic noise levels that tend to exceed the occupational exposure limits (both inside and outside the driver's cab). The levels of infrasound: 83,8-111,4 dB-G. All tractors introduced for sale should be subjected to tests in terms of infrasonic noise levels. The applicable standards for low frequency noise and its measurement methods for vehicles, including agricultural tractors, should be scientifically revised. In the last years there has been a noticeable technical progress in reduction of audible noise exposure at the tractors operators workplaces with simultaneously lack of important works for limitation of exposure to infrasound. Author discuss possible health and ergonomic consequencies of such exposure. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  9. Vowel perception by noise masked normal-hearing young adults

    NASA Astrophysics Data System (ADS)

    Richie, Carolyn; Kewley-Port, Diane; Coughlin, Maureen

    2005-08-01

    This study examined vowel perception by young normal-hearing (YNH) adults, in various listening conditions designed to simulate mild-to-moderate sloping sensorineural hearing loss. YNH listeners were individually age- and gender-matched to young hearing-impaired (YHI) listeners tested in a previous study [Richie et al., J. Acoust. Soc. Am. 114, 2923-2933 (2003)]. YNH listeners were tested in three conditions designed to create equal audibility with the YHI listeners; a low signal level with and without a simulated hearing loss, and a high signal level with a simulated hearing loss. Listeners discriminated changes in synthetic vowel tokens /smcapi e ɛ invv æ/ when F1 or F2 varied in frequency. Comparison of YNH with YHI results failed to reveal significant differences between groups in terms of performance on vowel discrimination, in conditions of similar audibility by using both noise masking to elevate the hearing thresholds of the YNH and applying frequency-specific gain to the YHI listeners. Further, analysis of learning curves suggests that while the YHI listeners completed an average of 46% more test blocks than YNH listeners, the YHI achieved a level of discrimination similar to that of the YNH within the same number of blocks. Apparently, when age and gender are closely matched between young hearing-impaired and normal-hearing adults, performance on vowel tasks may be explained by audibility alone.

  10. CAVITATION SOUNDS DURING CERVICOTHORACIC SPINAL MANIPULATION

    PubMed Central

    Mourad, Firas; Zingoni, Andrea; Iorio, Raffaele; Perreault, Thomas; Zacharko, Noah; de las Peñas, César Fernández; Butts, Raymond; Cleland, Joshua A.

    2017-01-01

    Background No study has previously investigated the side, duration or number of audible cavitation sounds during high-velocity low-amplitude (HVLA) thrust manipulation to the cervicothoracic spine. Purpose The primary purpose was to determine which side of the spine cavitates during cervicothoracic junction (CTJ) HVLA thrust manipulation. Secondary aims were to calculate the average number of cavitations, the duration of cervicothoracic thrust manipulation, and the duration of a single cavitation. Study Design Quasi-experimental study Methods Thirty-two patients with upper trapezius myalgia received two cervicothoracic HVLA thrust manipulations targeting the right and left T1-2 articulation, respectively. Two high sampling rate accelerometers were secured bilaterally 25 mm lateral to midline of the T1-2 interspace. For each manipulation, two audio signals were extracted using Short-Time Fourier Transformation (STFT) and singularly processed via spectrogram calculation in order to evaluate the frequency content and number of instantaneous energy bursts of both signals over time for each side of the CTJ. Result Unilateral cavitation sounds were detected in 53 (91.4%) of 58 cervicothoracic HVLA thrust manipulations and bilateral cavitation sounds were detected in just five (8.6%) of the 58 thrust manipulations; that is, cavitation was significantly (p<0.001) more likely to occur unilaterally than bilaterally. In addition, cavitation was significantly (p<0.0001) more likely to occur on the side contralateral to the clinician's short-lever applicator. The mean number of audible cavitations per manipulation was 4.35 (95% CI 2.88, 5.76). The mean duration of a single manipulation was 60.77 ms (95% CI 28.25, 97.42) and the mean duration of a single audible cavitation was 4.13 ms (95% CI 0.82, 7.46). In addition to single-peak and multi-peak energy bursts, spectrogram analysis also demonstrated high frequency sounds, low frequency sounds, and sounds of multiple frequencies for all 58 manipulations. Discussion Cavitation was significantly more likely to occur unilaterally, and on the side contralateral to the short-lever applicator contact, during cervicothoracic HVLA thrust manipulation. Clinicians should expect multiple cavitation sounds when performing HVLA thrust manipulation to the CTJ. Due to the presence of multi-peak energy bursts and sounds of multiple frequencies, the cavitation hypothesis (i.e. intra-articular gas bubble collapse) alone appears unable to explain all of the audible sounds during HVLA thrust manipulation, and the possibility remains that several phenomena may be occurring simultaneously. Level of Evidence 2b PMID:28900571

  11. Critical ratios of beluga whales (Delphinapterus leucas) and masked signal duration.

    PubMed

    Erbe, Christine

    2008-10-01

    This article examines the masking of a complex beluga vocalization by natural and anthropogenic noise. The call consisted of six 150 ms pulses exhibiting spectral peaks between 800 Hz and 8 kHz. Comparing the spectra and spectrograms of the call and noises at detection threshold showed that the animal did not hear the entire call at threshold. It only heard parts of the call in frequency and time. From the masked hearing thresholds in broadband continuous noises, critical ratios were computed. Fletcher critical bands were narrower than either 15 or 111 of an octave at the low frequencies of the call (<2 kHz), depending on which frequency the animal cued on. From the masked hearing thresholds in intermittent noises, the audible signal duration at detection threshold was computed. The intermittent noises differed in gap length, gap number, and masking, but the total audible signal duration at threshold was the same: 660 ms. This observation supports a multiple-looks model. The two amplitude modulated noises exhibited weaker masking than the unmodulated noises hinting at a comodulation masking release.

  12. Sonotropic effects of commercial air transport sound on birds.

    DOT National Transportation Integrated Search

    1962-03-01

    The Electra sound spectrum contains an audible chirp which appears identical in frequency and wave form to the chirp of field crickets. Field observations strongly indicate the sound of the taxiing Electra exerts an attraction for starlings, and poss...

  13. Binaural beats at high frequencies.

    PubMed

    McFadden, D; Pasanen, E G

    1975-10-24

    Binaural beats have long been believed to be audible only at low frequencies, but an interaction reminiscent of a binaural beat can sometimes be heard when different two-tone complexes of high frequency are presented to the two ears. The primary requirement is that the frequency separation in the complex at one ear be slightly different from that in the other--that is, that there be a small interaural difference in the envelope periodicities. This finding is in accord with other recent demonstrations that the auditory system is not deaf to interaural time differences at high frequencies.

  14. High-Frequency Amplification and Sound Quality in Listeners with Normal through Moderate Hearing Loss

    ERIC Educational Resources Information Center

    Ricketts, Todd A.; Dittberner, Andrew B.; Johnson, Earl E.

    2008-01-01

    Purpose: One factor that has been shown to greatly affect sound quality is audible bandwidth. Provision of gain for frequencies above 4-6 kHz has not generally been supported for groups of hearing aid wearers. The purpose of this study was to determine if preference for bandwidth extension in hearing aid processed sounds was related to the…

  15. Chirp-Z analysis for sol-gel transition monitoring.

    PubMed

    Martinez, Loïc; Caplain, Emmanuel; Serfaty, Stéphane; Griesmar, Pascal; Gouedard, Gérard; Gindre, Marcel

    2004-04-01

    Gelation is a complex reaction that transforms a liquid medium into a solid one: the gel. In gel state, some gel materials (DMAP) have the singular property to ring in an audible frequency range when a pulse is applied. Before the gelation point, there is no transmission of slow waves observed; after the gelation point, the speed of sound in the gel rapidly increases from 0.1 to 10 m/s. The time evolution of the speed of sound can be measured, in frequency domain, by following the frequency spacing of the resonance peaks from the Synchronous Detection (SD) measurement method. Unfortunately, due to a constant frequency sampling rate, the relative error for low speeds (0.1 m/s) is 100%. In order to maintain a low constant relative error, in the whole speed time evolution range, Chirp-Z Transform (CZT) is used. This operation transforms a time variant signal to a time invariant one using only a time dependant stretching factor (S). In the frequency domain, the CZT enables us to stretch each collected spectrum from time signals. The blind identification of the S factor gives us the complete time evolution law of the speed of sound. Moreover, this method proves that the frequency bandwidth follows the same time law. These results point out that the minimum wavelength stays constant and that it only depends on the gel.

  16. Wind turbines and human health.

    PubMed

    Knopper, Loren D; Ollson, Christopher A; McCallum, Lindsay C; Whitfield Aslund, Melissa L; Berger, Robert G; Souweine, Kathleen; McDaniel, Mary

    2014-01-01

    The association between wind turbines and health effects is highly debated. Some argue that reported health effects are related to wind turbine operation [electromagnetic fields (EMF), shadow flicker, audible noise, low-frequency noise, infrasound]. Others suggest that when turbines are sited correctly, effects are more likely attributable to a number of subjective variables that result in an annoyed/stressed state. In this review, we provide a bibliographic-like summary and analysis of the science around this issue specifically in terms of noise (including audible, low-frequency noise, and infrasound), EMF, and shadow flicker. Now there are roughly 60 scientific peer-reviewed articles on this issue. The available scientific evidence suggests that EMF, shadow flicker, low-frequency noise, and infrasound from wind turbines are not likely to affect human health; some studies have found that audible noise from wind turbines can be annoying to some. Annoyance may be associated with some self-reported health effects (e.g., sleep disturbance) especially at sound pressure levels >40 dB(A). Because environmental noise above certain levels is a recognized factor in a number of health issues, siting restrictions have been implemented in many jurisdictions to limit noise exposure. These setbacks should help alleviate annoyance from noise. Subjective variables (attitudes and expectations) are also linked to annoyance and have the potential to facilitate other health complaints via the nocebo effect. Therefore, it is possible that a segment of the population may remain annoyed (or report other health impacts) even when noise limits are enforced. Based on the findings and scientific merit of the available studies, the weight of evidence suggests that when sited properly, wind turbines are not related to adverse health. Stemming from this review, we provide a number of recommended best practices for wind turbine development in the context of human health.

  17. Wind Turbines and Human Health

    PubMed Central

    Knopper, Loren D.; Ollson, Christopher A.; McCallum, Lindsay C.; Whitfield Aslund, Melissa L.; Berger, Robert G.; Souweine, Kathleen; McDaniel, Mary

    2014-01-01

    The association between wind turbines and health effects is highly debated. Some argue that reported health effects are related to wind turbine operation [electromagnetic fields (EMF), shadow flicker, audible noise, low-frequency noise, infrasound]. Others suggest that when turbines are sited correctly, effects are more likely attributable to a number of subjective variables that result in an annoyed/stressed state. In this review, we provide a bibliographic-like summary and analysis of the science around this issue specifically in terms of noise (including audible, low-frequency noise, and infrasound), EMF, and shadow flicker. Now there are roughly 60 scientific peer-reviewed articles on this issue. The available scientific evidence suggests that EMF, shadow flicker, low-frequency noise, and infrasound from wind turbines are not likely to affect human health; some studies have found that audible noise from wind turbines can be annoying to some. Annoyance may be associated with some self-reported health effects (e.g., sleep disturbance) especially at sound pressure levels >40 dB(A). Because environmental noise above certain levels is a recognized factor in a number of health issues, siting restrictions have been implemented in many jurisdictions to limit noise exposure. These setbacks should help alleviate annoyance from noise. Subjective variables (attitudes and expectations) are also linked to annoyance and have the potential to facilitate other health complaints via the nocebo effect. Therefore, it is possible that a segment of the population may remain annoyed (or report other health impacts) even when noise limits are enforced. Based on the findings and scientific merit of the available studies, the weight of evidence suggests that when sited properly, wind turbines are not related to adverse health. Stemming from this review, we provide a number of recommended best practices for wind turbine development in the context of human health. PMID:24995266

  18. Acoustic dispersive prism.

    PubMed

    Esfahlani, Hussein; Karkar, Sami; Lissek, Herve; Mosig, Juan R

    2016-01-07

    The optical dispersive prism is a well-studied element, which allows separating white light into its constituent spectral colors, and stands in nature as water droplets. In analogy to this definition, the acoustic dispersive prism should be an acoustic device with capability of splitting a broadband acoustic wave into its constituent Fourier components. However, due to the acoustical nature of materials as well as the design and fabrication difficulties, there is neither any natural acoustic counterpart of the optical prism, nor any artificial design reported so far exhibiting an equivalent acoustic behaviour. Here, based on exotic properties of the acoustic transmission-line metamaterials and exploiting unique physical behaviour of acoustic leaky-wave radiation, we report the first acoustic dispersive prism, effective within the audible frequency range 800 Hz-1300 Hz. The dispersive nature, and consequently the frequency-dependent refractive index of the metamaterial are exploited to split the sound waves towards different and frequency-dependent directions. Meanwhile, the leaky-wave nature of the structure facilitates the sound wave radiation into the ambient medium.

  19. The Dynamic Range for Korean Standard Sentence Material: A Gender Comparison in a Male and a Female Speakers.

    PubMed

    Park, Kyeong-Yeon; Jin, In-Ki

    2015-09-01

    The purpose of this study was to identify differences between the dynamic ranges (DRs) of male and female speakers using Korean standard sentence material. Consideration was especially given to effects within the predefined segmentalized frequency-bands. We used Korean standard sentence lists for adults as stimuli. Each sentence was normalized to a root-mean-square of 65 dB sound pressure level. The sentences were then modified to ensure there were no pauses, and the modified sentences were passed through a filter bank in order to perform the frequency analysis. Finally, the DR was quantified using a histogram that showed the cumulative envelope distribution levels of the speech in each frequency band. In DRs that were averaged across all frequency bands, there were no significant differences between the male and the female speakers. However, when considering effects within the predefined frequency bands, there were significant differences in several frequency bands between the DRs of male speech and those of female speech. This study shows that the DR of speech for the male speaker differed from the female speaker in nine frequency bands among 21 frequency bands. These observed differences suggest that a standardized DR of male speech in the band-audibility function of the speech intelligibility index may differ from that of female speech derived in the same way. Further studies are required to derive standardized DRs for Korean speakers.

  20. Industrial wind turbines and adverse health effects.

    PubMed

    Jeffery, Roy D; Krogh, Carmen M E; Horner, Brett

    2014-01-01

    Some people living in the environs of industrial wind turbines (IWTs) report experiencing adverse health and socioeconomic effects. This review considers the hypothesis that annoyance from audible IWTs is the cause of these adverse health effects. We searched PubMed and Google Scholar for articles published since 2000 that included the terms "wind turbine health," "wind turbine infrasound," "wind turbine annoyance," "noise annoyance" or "low frequency noise" in the title or abstract. Industrial wind turbines produce sound that is perceived to be more annoying than other sources of sound. Reported effects from exposure to IWTs are consistent with well-known stress effects from persistent unwanted sound. If placed too close to residents, IWTs can negatively affect the physical, mental and social well-being of people. There is sufficient evidence to support the conclusion that noise from audible IWTs is a potential cause of health effects. Inaudible low-frequency noise and infrasound from IWTs cannot be ruled out as plausible causes of health effects.

  1. Electrocardiogram provides a continuous heart rate faster than oximetry during neonatal resuscitation.

    PubMed

    Katheria, Anup; Rich, Wade; Finer, Neil

    2012-11-01

    To compare the time required to obtain a continuous audible heart rate signal from an electrocardiogram (ECG) monitor and pulse oximeter (PO) in infants requiring resuscitation. Infants who had both ECG and PO placed during resuscitation were analyzed using video and analog recordings. The median times from arrival until the ECG electrodes and PO sensor were placed, and the time to achieve audible tones from the devices, were compared. Forty-six infants had ECG and PO data. Thirty infants were very low birth weight (23-30 weeks). There was a difference in the median total time to place either device (26 vs 38 seconds; P = .04), and a difference (P < .001) in the time to achieve an audible heart rate signal after ECG lead (2 seconds) versus PO probe (24 seconds) placement. In infants weighing >1500 g (n = 16), the median time (interquartile range) to place the ECG was 20 seconds (14-43) whereas the time to place the PO was 36 seconds (28-56) (P = .74). The median times (interquartile range) to acquire a signal from the ECG and PO were 4 seconds (1-6) and 32 seconds (15-40, P = .001), respectively. During the first minutes of resuscitation, 93% of infants had an ECG heart rate compared with only 56% for PO. Early application of ECG electrodes during infant resuscitation can provide the resuscitation team with a continuous audible heart rate, and its use may improve the timeliness of appropriate critical interventions.

  2. Flow control using audio tones in resonant microfluidic networks: towards cell-phone controlled lab-on-a-chip devices.

    PubMed

    Phillips, Reid H; Jain, Rahil; Browning, Yoni; Shah, Rachana; Kauffman, Peter; Dinh, Doan; Lutz, Barry R

    2016-08-16

    Fluid control remains a challenge in development of portable lab-on-a-chip devices. Here, we show that microfluidic networks driven by single-frequency audio tones create resonant oscillating flow that is predicted by equivalent electrical circuit models. We fabricated microfluidic devices with fluidic resistors (R), inductors (L), and capacitors (C) to create RLC networks with band-pass resonance in the audible frequency range available on portable audio devices. Microfluidic devices were fabricated from laser-cut adhesive plastic, and a "buzzer" was glued to a diaphragm (capacitor) to integrate the actuator on the device. The AC flowrate magnitude was measured by imaging oscillation of bead tracers to allow direct comparison to the RLC circuit model across the frequency range. We present a systematic build-up from single-channel systems to multi-channel (3-channel) networks, and show that RLC circuit models predict complex frequency-dependent interactions within multi-channel networks. Finally, we show that adding flow rectifying valves to the network creates pumps that can be driven by amplified and non-amplified audio tones from common audio devices (iPod and iPhone). This work shows that RLC circuit models predict resonant flow responses in multi-channel fluidic networks as a step towards microfluidic devices controlled by audio tones.

  3. Thermal tuning on band gaps of 2D phononic crystals considering adhesive layers

    NASA Astrophysics Data System (ADS)

    Zhou, Xiaoliang; Chen, Jialin; Li, Yuhang; Sun, Yuxin; Xing, Yufeng

    2018-02-01

    Phononic crystals are very attractive in many applications, such as noise reduction, filters and vibration isolation, due to their special forbidden band gap structures. In the present paper, the investigation of tunable band gaps of 2D phononic crystals with adhesive layers based on thermal changing is conducted. Based on the lumped-mass method, an analytical model of 2D phononic crystals with relatively thin adhesive layers is established, in which the in-plane and out-of-plane modes are both in consideration. The adhesive material is sensitive to temperature so that the band structure can be tuned and controlled by temperature variation. As temperature increases from 20 °C-80 °C, the first band gap shifts to the frequency zone around 10 kHz, which is included by the audible frequency range. The results propose an important guideline for applications, such as noise suppression using the 2D phononic crystals.

  4. Rectification of Lamb wave propagation in thin plates with piezo-dielectric periodic structures

    NASA Astrophysics Data System (ADS)

    Iwasaki, Yuhei; Tsuruta, Kenji; Ishikawa, Atsushi

    2016-07-01

    Based on a heterostructured plate consisting of piezoelectric-ceramic/epoxy-resin composites with different periodicities, we design a novel acoustic diode for the symmetrical/asymmetrical (S/A) mode of Lamb wave at audible ranges. The acoustic diode is constructed with two parts, i.e., the mode conversion part and the mode selection part, and the mode conversion mechanism at the interface is applied to the mode hybridization from S to S+A and for the mode conversion from A to S. The phonon band structures for each part are calculated and optimized so that the mode selection is realized for a specific mode at the junction. Finite-element simulations prove that the proposed acoustic diode achieves efficient rectification at audio frequency ranges for both S and A mode incidences of the Lamb wave.

  5. Exploring the limits of frequency lowering

    PubMed Central

    Souza, Pamela E.; Arehart, Kathryn H.; Kates, James M.; Croghan, Naomi B.H.; Gehani, Namita

    2013-01-01

    Objective This study examined how frequency lowering affected sentence intelligibility and quality, for adults with postlingually acquired, mild-to-moderate hearing loss. Method Listeners included adults aged 60–92 years with sloping sensorineural loss and a control group of similarly-aged adults with normal hearing. Sentences were presented in quiet and babble at a range of signal-to-noise ratios. Intelligibility and quality were measured with varying amounts of frequency lowering, implemented using a form of frequency compression. Results Moderate amounts of compression, particularly with high cutoff frequencies, had minimal effects on intelligibility. Listeners with the greatest high-frequency hearing loss showed the greatest benefit. Sentence intelligibility decreased with more compression. Listeners were more affected by a given set of parameters in noise. In quiet, any amount of compression resulted in lower speech quality for most listeners, with the greatest degradation for listeners with better high-frequency hearing. Quality ratings were lower with background noise, and in noise the effect of changing compression parameters was small. Conclusions The benefits of frequency lowering in adults were affected by the compression parameters as well as individual hearing thresholds. Data are consistent with the idea that frequency lowering can be viewed in terms of an improved audibility vs increased distortion tradeoff. PMID:23785188

  6. Changes in vocal parameters with social context in humpback whales: considering the effect of bystanders.

    PubMed

    Dunlop, Rebecca A

    Many theories and communication models developed from terrestrial studies focus on a simple dyadic exchange between a sender and receiver. During social interactions, the "frequency code" hypothesis suggests that frequency characteristics of vocal signals can simultaneously encode for static signaler attributes (size or sex) and dynamic information, such as motivation or emotional state. However, the additional presence of a bystander may result in a change of signaling behavior if the costs and benefits associated with the presence of this bystander are different from that of a simple dyad. In this study, two common humpback whale social calls ("wops" and "grumbles") were tested for differences related to group social behavior and the presence of bystanders. "Wop" parameters were stable with group social behavior, but were emitted at lower (14 dB) levels in the presence of a nearby singing whale compared to when a singing whale was not in the area. "Grumbles" were emitted at lower (30-39 Hz) fundamental frequencies in affiliative compared to non-affiliative groups and, in the presence of a nearby singing whale, were also emitted at lower (14 dB) levels. Vocal rates did not significantly change. The results suggest that, in humpbacks, the frequency in certain sound types relates to the social behavior of the vocalizing group, implying a frequency code system. The presence of a nearby audible bystander (a singing whale) had no effect on this frequency code, but by reducing their acoustic level, the signal-to-noise ratio at the singer would have been below 0, making it difficult for the singer to audibly detect the group. The frequency, duration, and amplitude parameters of humpback whale social vocalizations were tested between different social contexts: group social behavior (affiliating versus non-affiliating), the presence of a nearby singing whale, and the presence of a nearby non-singing group. "Grumbles" (commonly heard low-frequency unmodulated sounds) frequencies were lower in affiliating groups compared to non-affiliating groups, suggesting a change in group motivation (such as levels of aggression). "Wop" (another common sound type) structure (frequency and duration) was similar in affiliating and non-affiliating groups. In the presence of an audible bystander (a singing whale), both sound types were emitted at similar rates, but much lower amplitudes (14 dB), vastly reducing the detectability of these sounds by the singer. This suggests that these groups were acoustically avoiding the singing whale. They did not, however, acoustically respond to the presence of a nearby non-singing group.

  7. A crossover trial comparing wide dynamic range compression and frequency compression in hearing aids for tinnitus therapy.

    PubMed

    Hodgson, Shirley-Anne; Herdering, Regina; Singh Shekhawat, Giriraj; Searchfield, Grant D

    2017-01-01

    It has been suggested that frequency lowering may be a superior tinnitus reducing digital signal processing (DSP) strategy in hearing aids than conventional amplification. A crossover trial was undertaken to determine if frequency compression (FC) was superior to wide dynamic range compression (WDRC) in reducing tinnitus. A 6-8-week crossover trial of two digital signal-processing techniques (WDRC and 2 WDRC with FC) was undertaken in 16 persons with high-frequency sensorineural hearing loss and chronic tinnitus. WDRC resulted in larger improvements in Tinnitus Functional Index and rating scale scores than WDRC with FC. The tinnitus improvements obtained with both processing types appear to be due to reduced hearing handicap and possibly decreased tinnitus audibility. Hearing aids are useful assistive devices in the rehabilitation of tinnitus. FC was very successful in a few individuals but was not superior to WDRC across the sample. It is recommended that WDRC remain as the default first choice tinnitus hearing aid processing strategy for tinnitus. FC should be considered as one of the many other options for selection based on individual hearing needs. Implications of Rehabilitation Hearing aids can significantly reduce the effects of tinnitus after 6-8 weeks of use. Addition of frequency compression digital signal processing does not appear superior to standard amplitude compression alone. Improvements in tinnitus were correlated with reductions in hearing handicap.

  8. Surface response of a fractional order viscoelastic halfspace to surface and subsurface sources

    PubMed Central

    Meral, F. Can; Royston, Thomas J.; Magin, Richard L.

    2009-01-01

    Previous studies by the second author published in this journal focused on low audible frequency (40–400 Hz) shear and surface wave motion in and on a viscoelastic material representative of biological tissue. Specific cases considered were that of surface wave motion on a halfspace caused by a finite rigid circular disk located on the surface and oscillating normal to it [Royston et al., J. Acoust. Soc. Am. 106, 3678–3686 (1999)] and compression, shear, and surface wave motion in a halfspace generated by a subsurface finite dipole [Royston et al., J. Acoust. Soc. Am. 113, 1109–1121 (2003)]. In both studies, a Voigt model of viscoelasticity was assumed in the theoretical treatment, which resulted in agreement between theoretical predictions and experimental measurements over a limited frequency range. In the present article, the linear viscoelastic assumption in these two prior works is revisited to consider a (still linear) fractional order Voigt model, where the rate-dependent damping component that is dependent on the first derivative of time is replaced with a component that is dependent on a fractional derivative of time. It is shown that in both excitation source configurations, the fractional order Voigt model assumption improves the match of theory to experiment over a wider frequency range (in some cases up to the measured range of 700 Hz). PMID:20000941

  9. Evaluation of a multi-channel algorithm for reducing transient sounds.

    PubMed

    Keshavarzi, Mahmoud; Baer, Thomas; Moore, Brian C J

    2018-05-15

    The objective was to evaluate and select appropriate parameters for a multi-channel transient reduction (MCTR) algorithm for detecting and attenuating transient sounds in speech. In each trial, the same sentence was played twice. A transient sound was presented in both sentences, but its level varied across the two depending on whether or not it had been processed by the MCTR and on the "strength" of the processing. The participant indicated their preference for which one was better and by how much in terms of the balance between the annoyance produced by the transient and the audibility of the transient (they were told that the transient should still be audible). Twenty English-speaking participants were tested, 10 with normal hearing and 10 with mild-to-moderate hearing-impairment. Frequency-dependent linear amplification was provided for the latter. The results for both participant groups indicated that sounds processed using the MCTR were preferred over the unprocessed sounds. For the hearing-impaired participants, the medium and strong settings of the MCTR were preferred over the weak setting. The medium and strong settings of the MCTR reduced the annoyance produced by the transients while maintaining their audibility.

  10. Towards direct realisation of the SI unit of sound pressure in the audible hearing range based on optical free-field acoustic particle measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koukoulas, Triantafillos, E-mail: triantafillos.koukoulas@npl.co.uk; Piper, Ben

    Since the introduction of the International System of Units (the SI system) in 1960, weights, measures, standardised approaches, procedures, and protocols have been introduced, adapted, and extensively used. A major international effort and activity concentrate on the definition and traceability of the seven base SI units in terms of fundamental constants, and consequently those units that are derived from the base units. In airborne acoustical metrology and for the audible range of frequencies up to 20 kHz, the SI unit of sound pressure, the pascal, is realised indirectly and without any knowledge or measurement of the sound field. Though themore » principle of reciprocity was originally formulated by Lord Rayleigh nearly two centuries ago, it was devised in the 1940s and eventually became a calibration standard in the 1960s; however, it can only accommodate a limited number of acoustic sensors of specific types and dimensions. International standards determine the device sensitivity either through coupler or through free-field reciprocity but rely on the continuous availability of specific acoustical artefacts. Here, we show an optical method based on gated photon correlation spectroscopy that can measure sound pressures directly and absolutely in fully anechoic conditions, remotely, and without disturbing the propagating sound field. It neither relies on the availability or performance of any measurement artefact nor makes any assumptions of the device geometry and sound field characteristics. Most importantly, the required units of sound pressure and microphone sensitivity may now be experimentally realised, thus providing direct traceability to SI base units.« less

  11. Power conversion distribution system using a resonant high-frequency AC link

    NASA Technical Reports Server (NTRS)

    Sood, P. K.; Lipo, T. A.

    1986-01-01

    Static power conversion systems based on a resonant high frequency (HF) link offers a significant reduction in the size and weight of the equipment over that achieved with conventional approaches, especially when multiple sources and loads are to be integrated. A faster system response and absence of audible noise are the other principal characteristics of such systems. A conversion configuration based on a HF link which is suitable for applications requiring distributed power is proposed.

  12. A microelectromechanical system artificial basilar membrane based on a piezoelectric cantilever array and its characterization using an animal model.

    PubMed

    Jang, Jongmoon; Lee, JangWoo; Woo, Seongyong; Sly, David J; Campbell, Luke J; Cho, Jin-Ho; O'Leary, Stephen J; Park, Min-Hyun; Han, Sungmin; Choi, Ji-Wong; Jang, Jeong Hun; Choi, Hongsoo

    2015-07-31

    We proposed a piezoelectric artificial basilar membrane (ABM) composed of a microelectromechanical system cantilever array. The ABM mimics the tonotopy of the cochlea: frequency selectivity and mechanoelectric transduction. The fabricated ABM exhibits a clear tonotopy in an audible frequency range (2.92-12.6 kHz). Also, an animal model was used to verify the characteristics of the ABM as a front end for potential cochlear implant applications. For this, a signal processor was used to convert the piezoelectric output from the ABM to an electrical stimulus for auditory neurons. The electrical stimulus for auditory neurons was delivered through an implanted intra-cochlear electrode array. The amplitude of the electrical stimulus was modulated in the range of 0.15 to 3.5 V with incoming sound pressure levels (SPL) of 70.1 to 94.8 dB SPL. The electrical stimulus was used to elicit an electrically evoked auditory brainstem response (EABR) from deafened guinea pigs. EABRs were successfully measured and their magnitude increased upon application of acoustic stimuli from 75 to 95 dB SPL. The frequency selectivity of the ABM was estimated by measuring the magnitude of EABRs while applying sound pressure at the resonance and off-resonance frequencies of the corresponding cantilever of the selected channel. In this study, we demonstrated a novel piezoelectric ABM and verified its characteristics by measuring EABRs.

  13. 49 CFR 214.339 - Audible warning from trains.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Audible warning from trains. 214.339 Section 214... Audible warning from trains. Each railroad shall require that the locomotive whistle be sounded, and the locomotive bell be rung, by trains approaching roadway workers on or about the track. Such audible warning...

  14. 49 CFR 230.85 - Audible warning device.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Audible warning device. 230.85 Section 230.85... Tenders Cabs, Warning Signals, Sanders and Lights § 230.85 Audible warning device. (a) General provisions. Each steam locomotive shall be equipped with an audible warning device that produces a minimum sound...

  15. 49 CFR 230.85 - Audible warning device.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Audible warning device. 230.85 Section 230.85... Tenders Cabs, Warning Signals, Sanders and Lights § 230.85 Audible warning device. (a) General provisions. Each steam locomotive shall be equipped with an audible warning device that produces a minimum sound...

  16. 49 CFR 214.339 - Audible warning from trains.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Audible warning from trains. 214.339 Section 214... Audible warning from trains. Each railroad shall require that the locomotive whistle be sounded, and the locomotive bell be rung, by trains approaching roadway workers on or about the track. Such audible warning...

  17. 49 CFR 214.339 - Audible warning from trains.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Audible warning from trains. 214.339 Section 214... Audible warning from trains. Each railroad shall require that the locomotive whistle be sounded, and the locomotive bell be rung, by trains approaching roadway workers on or about the track. Such audible warning...

  18. 49 CFR 214.339 - Audible warning from trains.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Audible warning from trains. 214.339 Section 214... Audible warning from trains. Each railroad shall require that the locomotive whistle be sounded, and the locomotive bell be rung, by trains approaching roadway workers on or about the track. Such audible warning...

  19. 49 CFR 230.85 - Audible warning device.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Audible warning device. 230.85 Section 230.85... Tenders Cabs, Warning Signals, Sanders and Lights § 230.85 Audible warning device. (a) General provisions. Each steam locomotive shall be equipped with an audible warning device that produces a minimum sound...

  20. 49 CFR 230.85 - Audible warning device.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Audible warning device. 230.85 Section 230.85... Tenders Cabs, Warning Signals, Sanders and Lights § 230.85 Audible warning device. (a) General provisions. Each steam locomotive shall be equipped with an audible warning device that produces a minimum sound...

  1. 49 CFR 214.339 - Audible warning from trains.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Audible warning from trains. 214.339 Section 214... Audible warning from trains. Each railroad shall require that the locomotive whistle be sounded, and the locomotive bell be rung, by trains approaching roadway workers on or about the track. Such audible warning...

  2. 49 CFR 230.85 - Audible warning device.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Audible warning device. 230.85 Section 230.85... Tenders Cabs, Warning Signals, Sanders and Lights § 230.85 Audible warning device. (a) General provisions. Each steam locomotive shall be equipped with an audible warning device that produces a minimum sound...

  3. Pure tone audiograms and possible aminoglycoside-induced hearing loss in belugas (Delphinapterus leucas)

    NASA Astrophysics Data System (ADS)

    Finneran, James J.; Carder, Donald A.; Dear, Randall; Belting, Traci; McBain, Jim; Dalton, Les; Ridgway, Sam H.

    2005-06-01

    A behavioral response paradigm was used to measure pure-tone hearing sensitivities in two belugas (Delphinapterus leucas). Tests were conducted over a 20-month period at the Point Defiance Zoo and Aquarium, in Tacoma, WA. Subjects were two males, aged 8-10 and 9-11 during the course of the study. Subjects were born in an oceanarium and had been housed together for all of their lives. Hearing thresholds were measured using a modified up/down staircase procedure and acoustic response paradigm where subjects were trained to produce audible responses to test tones and to remain quiet otherwise. Test frequencies ranged from approximately 2 to 130 kHz. Best sensitivities ranged from approximately 40 to 50 dB re 1 μPa at 50-80 kHz and 30-35 kHz for the two subjects. Although both subjects possessed traditional ``U-shaped'' mammalian audiograms, one subject exhibited significant high-frequency hearing loss above 37 kHz compared to previously published data for belugas. Hearing loss in this subject was estimated to approach 90 dB for frequencies above 50 kHz. Similar ages, ancestry, and environmental conditions between subjects, but a history of ototoxic drug administration in only one subject, suggest that the observed hearing loss was a result of the aminoglycoside antibiotic amikacin. .

  4. Pure tone audiograms and possible aminoglycoside-induced hearing loss in belugas (Delphinapterus leucas).

    PubMed

    Finneran, James J; Carder, Donald A; Dear, Randall; Belting, Traci; McBain, Jim; Dalton, Les; Ridgway, Sam H

    2005-06-01

    A behavioral response paradigm was used to measure pure-tone hearing sensitivities in two belugas (Delphinapterus leucas). Tests were conducted over a 20-month period at the Point Defiance Zoo and Aquarium, in Tacoma, WA. Subjects were two males, aged 8-10 and 9-11 during the course of the study. Subjects were born in an oceanarium and had been housed together for all of their lives. Hearing thresholds were measured using a modified up/down staircase procedure and acoustic response paradigm where subjects were trained to produce audible responses to test tones and to remain quiet otherwise. Test frequencies ranged from approximately 2 to 130 kHz. Best sensitivities ranged from approximately 40 to 50 dB re 1 microPa at 50-80 kHz and 30-35 kHz for the two subjects. Although both subjects possessed traditional "U-shaped" mammalian audiograms, one subject exhibited significant high-frequency hearing loss above 37 kHz compared to previously published data for belugas. Hearing loss in this subject was estimated to approach 90 dB for frequencies above 50 kHz. Similar ages, ancestry, and environmental conditions between subjects, but a history of ototoxic drug administration in only one subject, suggest that the observed hearing loss was a result of the aminoglycoside antibiotic amikacin.

  5. On noninvasive assessment of acoustic fields acting on the fetus

    NASA Astrophysics Data System (ADS)

    Antonets, V. A.; Kazakov, V. V.

    2014-05-01

    The aim of this study is to verify a noninvasive technique for assessing the characteristics of acoustic fields in the audible range arising in the uterus under the action of maternal voice, external sounds, and vibrations. This problem is very important in view of actively developed methods for delivery of external sounds to the uterus: music, maternal voice recordings, sounds from outside the mother's body, etc., that supposedly support development of the fetus at the prenatal stage psychologically and cognitively. However, the parameters of acoustic signals have been neither measured nor normalized, which may be dangerous for the fetus and hinder actual assessment of their impact on fetal development. The authors show that at frequencies below 1 kHz, acoustic pressure in the uterus may be measured noninvasively using a hydrophone placed in a soft capsule filled with liquid. It was found that the acoustic field at frequencies up to 1 kHz arising in the uterus under the action of an external sound field has amplitude-frequency parameters close to those of the external field; i.e., the external field penetrates the uterus with hardly any difficulty.

  6. Sentence intelligibility during segmental interruption and masking by speech-modulated noise: Effects of age and hearing loss

    PubMed Central

    Fogerty, Daniel; Ahlstrom, Jayne B.; Bologna, William J.; Dubno, Judy R.

    2015-01-01

    This study investigated how single-talker modulated noise impacts consonant and vowel cues to sentence intelligibility. Younger normal-hearing, older normal-hearing, and older hearing-impaired listeners completed speech recognition tests. All listeners received spectrally shaped speech matched to their individual audiometric thresholds to ensure sufficient audibility with the exception of a second younger listener group who received spectral shaping that matched the mean audiogram of the hearing-impaired listeners. Results demonstrated minimal declines in intelligibility for older listeners with normal hearing and more evident declines for older hearing-impaired listeners, possibly related to impaired temporal processing. A correlational analysis suggests a common underlying ability to process information during vowels that is predictive of speech-in-modulated noise abilities. Whereas, the ability to use consonant cues appears specific to the particular characteristics of the noise and interruption. Performance declines for older listeners were mostly confined to consonant conditions. Spectral shaping accounted for the primary contributions of audibility. However, comparison with the young spectral controls who received identical spectral shaping suggests that this procedure may reduce wideband temporal modulation cues due to frequency-specific amplification that affected high-frequency consonants more than low-frequency vowels. These spectral changes may impact speech intelligibility in certain modulation masking conditions. PMID:26093436

  7. Perfect and broadband acoustic absorption by critically coupled sub-wavelength resonators.

    PubMed

    Romero-García, V; Theocharis, G; Richoux, O; Merkel, A; Tournat, V; Pagneux, V

    2016-01-19

    Perfect absorption is an interdisciplinary topic with a large number of applications, the challenge of which consists of broadening its inherently narrow frequency-band performance. We experimentally and analytically report perfect and broadband absorption for audible sound, by the mechanism of critical coupling, with a sub-wavelength multi-resonant scatterer (SMRS) made of a plate-resonator/closed waveguide structure. In order to introduce the role of the key parameters, we first present the case of a single resonant scatterer (SRS) made of a Helmholtz resonator/closed waveguide structure. In both cases the controlled balance between the energy leakage of the several resonances and the inherent losses of the system leads to perfect absorption peaks. In the case of the SMRS we show that systems with large inherent losses can be critically coupled using resonances with large leakage. In particular, we show that in the SMRS system, with a thickness of λ/12 and diameter of λ/7, several perfect absorption peaks overlap to produce absorption bigger than 93% for frequencies that extend over a factor of 2 in audible frequencies. The reported concepts and methodology provide guidelines for the design of broadband perfect absorbers which could contribute to solve the major issue of noise reduction.

  8. Perfect and broadband acoustic absorption by critically coupled sub-wavelength resonators

    NASA Astrophysics Data System (ADS)

    Romero-García, V.; Theocharis, G.; Richoux, O.; Merkel, A.; Tournat, V.; Pagneux, V.

    2016-01-01

    Perfect absorption is an interdisciplinary topic with a large number of applications, the challenge of which consists of broadening its inherently narrow frequency-band performance. We experimentally and analytically report perfect and broadband absorption for audible sound, by the mechanism of critical coupling, with a sub-wavelength multi-resonant scatterer (SMRS) made of a plate-resonator/closed waveguide structure. In order to introduce the role of the key parameters, we first present the case of a single resonant scatterer (SRS) made of a Helmholtz resonator/closed waveguide structure. In both cases the controlled balance between the energy leakage of the several resonances and the inherent losses of the system leads to perfect absorption peaks. In the case of the SMRS we show that systems with large inherent losses can be critically coupled using resonances with large leakage. In particular, we show that in the SMRS system, with a thickness of λ/12 and diameter of λ/7, several perfect absorption peaks overlap to produce absorption bigger than 93% for frequencies that extend over a factor of 2 in audible frequencies. The reported concepts and methodology provide guidelines for the design of broadband perfect absorbers which could contribute to solve the major issue of noise reduction.

  9. Perfect and broadband acoustic absorption by critically coupled sub-wavelength resonators

    PubMed Central

    Romero-García, V.; Theocharis, G.; Richoux, O.; Merkel, A.; Tournat, V.; Pagneux, V.

    2016-01-01

    Perfect absorption is an interdisciplinary topic with a large number of applications, the challenge of which consists of broadening its inherently narrow frequency-band performance. We experimentally and analytically report perfect and broadband absorption for audible sound, by the mechanism of critical coupling, with a sub-wavelength multi-resonant scatterer (SMRS) made of a plate-resonator/closed waveguide structure. In order to introduce the role of the key parameters, we first present the case of a single resonant scatterer (SRS) made of a Helmholtz resonator/closed waveguide structure. In both cases the controlled balance between the energy leakage of the several resonances and the inherent losses of the system leads to perfect absorption peaks. In the case of the SMRS we show that systems with large inherent losses can be critically coupled using resonances with large leakage. In particular, we show that in the SMRS system, with a thickness of λ/12 and diameter of λ/7, several perfect absorption peaks overlap to produce absorption bigger than 93% for frequencies that extend over a factor of 2 in audible frequencies. The reported concepts and methodology provide guidelines for the design of broadband perfect absorbers which could contribute to solve the major issue of noise reduction. PMID:26781863

  10. Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line

    NASA Astrophysics Data System (ADS)

    Liu, Yingyi; Zhou, Lijuan; Liu, Yuanqing; Yuan, Haiwen; Ji, Liang

    2017-11-01

    Audible noise is closely related to corona current on a high voltage direct current (HVDC) transmission line. In this paper, we measured a large amount of audible noise and corona current waveforms simultaneously based on the largest outdoor HVDC corona cage all over the world. By analyzing the experimental data, the related statistical regularities between a corona current spectrum and an audible noise spectrum were obtained. Furthermore, the generation mechanism of audible noise was analyzed theoretically, and the related mathematical expression between the audible noise spectrum and the corona current spectrum, which is suitable for all of these measuring points in the space, has been established based on the electro-acoustic conversion theory. Finally, combined with the obtained mathematical relation, the internal reasons for these statistical regularities appearing in measured corona current and audible noise data were explained. The results of this paper not only present the statistical association regularities between the corona current spectrum and the audible noise spectrum on a HVDC transmission line, but also reveal the inherent reasons of these associated rules.

  11. PERSONAL RADIATION MONITOR

    DOEpatents

    Dilworth, R.H.; Borkowski, C.J.

    1961-12-26

    A transistorized, fountain pen type radiation monitor to be worn on the person is described. Radiation produces both light flashes in a small bulb and an audible warning tone, the frequency of both the tone and light flashes being proportional to radiation intensity. The device is powered by a battery and a blocking oscillator step-up power supply The oscillator frequency- is regulated to be proportional to the radiation intensity, to provide adequate power in high radiation fields, yet minimize battery drain at low operating intensities. (AEC)

  12. Marine mammal audibility of selected shallow-water survey sources.

    PubMed

    MacGillivray, Alexander O; Racca, Roberto; Li, Zizheng

    2014-01-01

    Most attention about the acoustic effects of marine survey sound sources on marine mammals has focused on airgun arrays, with other common sources receiving less scrutiny. Sound levels above hearing threshold (sensation levels) were modeled for six marine mammal species and seven different survey sources in shallow water. The model indicated that odontocetes were most likely to hear sounds from mid-frequency sources (fishery, communication, and hydrographic systems), mysticetes from low-frequency sources (sub-bottom profiler and airguns), and pinnipeds from both mid- and low-frequency sources. High-frequency sources (side-scan and multibeam) generated the lowest estimated sensation levels for all marine mammal species groups.

  13. Determining the speed of sound in the air by sound wave interference

    NASA Astrophysics Data System (ADS)

    Silva, Abel A.

    2017-07-01

    Mechanical waves propagate through material media. Sound is an example of a mechanical wave. In fluids like air, sound waves propagate through successive longitudinal perturbations of compression and decompression. Audible sound frequencies for human ears range from 20 to 20 000 Hz. In this study, the speed of sound v in the air is determined using the identification of maxima of interference from two synchronous waves at frequency f. The values of v were correct to 0 °C. The experimental average value of {\\bar{ν }}\\exp =336 +/- 4 {{m}} {{{s}}}-1 was found. It is 1.5% larger than the reference value. The standard deviation of 4 m s-1 (1.2% of {\\bar{ν }}\\exp ) is an improved value by the use of the concept of the central limit theorem. The proposed procedure to determine the speed of sound in the air aims to be an academic activity for physics classes of scientific and technological courses in college.

  14. Large endolymphatic potentials from low-frequency and infrasonic tones in the guinea pig.

    PubMed

    Salt, Alec N; Lichtenhan, Jeffery T; Gill, Ruth M; Hartsock, Jared J

    2013-03-01

    Responses of the ear to low-frequency and infrasonic sounds have not been extensively studied. Understanding how the ear responds to low frequencies is increasingly important as environmental infrasounds are becoming more pervasive from sources such as wind turbines. This study shows endolymphatic potentials in the third cochlear turn from acoustic infrasound (5 Hz) are larger than from tones in the audible range (e.g., 50 and 500 Hz), in some cases with peak-to-peak amplitude greater than 20 mV. These large potentials were suppressed by higher-frequency tones and were rapidly abolished by perilymphatic injection of KCl at the cochlear apex, demonstrating their third-turn origins. Endolymphatic iso-potentials from 5 to 500 Hz were enhanced relative to perilymphatic potentials as frequency was lowered. Probe and infrasonic bias tones were used to study the origin of the enhanced potentials. Potentials were best explained as a saturating response summed with a sinusoidal voltage (Vo), that was phase delayed by an average of 60° relative to the biasing effects of the infrasound. Vo is thought to arise indirectly from hair cell activity, such as from strial potential changes caused by sustained current changes through the hair cells in each half cycle of the infrasound.

  15. Is metal-on-metal squeaking related to acetabular angle of inclination?

    PubMed

    Bernasek, Thomas; Fisher, David; Dalury, David; Levering, Melissa; Dimitris, Kirk

    2011-09-01

    Postoperative audible squeaking has been well documented in ceramic-on-ceramic hip prostheses, and several metal-on-metal (MOM) THA designs, specifically those used for large-head resurfacing and MOM polyethylene sandwich designs, and are attributed to different implant- and patient-specific factors. Current literature does not identify the incidence of squeaking in modular MOM THA or possible etiologic factors. Our purposes were to (1) identify the incidence of squeaking in modular MOM prostheses in THA; (2) determine whether males or females were more likely to have squeaking; and (3) determine whether the incidence of squeaking relates to acetabular inclination angle. We retrospectively reviewed the patient records and radiographs of 539 patients (542 hips) from three independent centers who underwent a MOM THA between February 2001 and December 2005. Demographic and implant factors were evaluated, including measurement of cup inclination angles. The minimum followup was 36 months (mean, 76 months; range, 36-119 months). We identified squeaking in eight of the 542 hips (1.5%); five were in women and two were in men (one patient had bilateral squeaking). The time to onset of patient-reported audible squeaking averaged 23 months (range, 6-84 months). Squeaking was more likely to occur in women (six of eight hips). No hips with 45º or less acetabular inclination squeaked (291 hips); eight of 251 hips (3.2%) with inclination angles greater than 45º squeaked. Patients who reported squeaking had higher inclination angles than those who did not report squeaking. Our observations suggest an increased frequency of squeaking in female patients and in patients with greater inclination angles with this MOM implant design.

  16. Enhanced and reduced transmission of acoustic waves with bubble meta-screens

    NASA Astrophysics Data System (ADS)

    Bretagne, Alice; Tourin, Arnaud; Leroy, Valentin

    2011-11-01

    We present a class of sonic meta-screens for manipulating air-borne acoustic waves at ultrasonic or audible frequencies. Our screens consist of periodic arrangements of air bubbles in water or possibly embedded in a soft elastic matrix. They can be used for soundproofing but also for exalting transmission at an air/water interface or even to achieve enhanced absorption.

  17. Loudness of steady sounds - A new theory

    NASA Technical Reports Server (NTRS)

    Howes, W. L.

    1979-01-01

    A new mathematical theory for calculating the loudness of steady sounds from power summation and frequency interaction, based on psychoacoustic and physiological information, assuems that loudness is a subjective measure of the electrical energy transmitted along the auditory nerve to the central nervous system. The auditory system consists of the mechanical part modeled by a bandpass filter with a transfer function dependent on the sound pressure, and the electrical part where the signal is transformed into a half-wave reproduction represented by the electrical power in impulsive discharges transmitted along neurons comprising the auditory nerve. In the electrical part the neurons are distributed among artificial parallel channels with frequency bandwidths equal to 'critical bandwidths for loudness', within which loudness is constant for constant sound pressure. The total energy transmitted to the central nervous system is the sum of the energy transmitted in all channels, and the loudness is proportional to the square root of the total filtered sound energy distributed over all channels. The theory explains many psychoacoustic phenomena such as audible beats resulting from closely spaced tones, interaction of sound stimuli which affect the same neurons affecting loudness, and of individually subliminal sounds becoming audible if they lie within the same critical band.

  18. Perception of binary acoustic events associated with the first heart sound

    NASA Technical Reports Server (NTRS)

    Spodick, D. H.

    1977-01-01

    The resolving power of the auditory apparatus permits discrete vibrations associated with cardiac activity to be perceived as one or more events. Irrespective of the vibratory combinations recorded by conventional phonocardiography, in normal adults and in most adult patients auscultators tend to discriminate only two discrete events associated with the first heart sound S1. It is stressed that the heart sound S4 may be present when a binary acoustic event associated with S1 occurs in the sequence 'low pitched sound preceding high pitched sound', i.e., its components are perceived by auscultation as 'dull-sharp'. The question of S4 audibility arises in those individuals, normal and diseased, in whom the major components of S1 ought to be, at least clinically, at their customary high pitch and indeed on the PCG appear as high frequency oscillations. It is revealed that the apparent audibility of recorded S4 is not related to P-R interval, P-S4 interval, or relative amplitude of S4. The significant S4-LFC (low frequency component of S1) differences can be related to acoustic modification of the early component of S1.

  19. A microelectromechanical system artificial basilar membrane based on a piezoelectric cantilever array and its characterization using an animal model

    PubMed Central

    Jang, Jongmoon; Lee, JangWoo; Woo, Seongyong; Sly, David J.; Campbell, Luke J.; Cho, Jin-Ho; O’Leary, Stephen J.; Park, Min-Hyun; Han, Sungmin; Choi, Ji-Wong; Hun Jang, Jeong; Choi, Hongsoo

    2015-01-01

    We proposed a piezoelectric artificial basilar membrane (ABM) composed of a microelectromechanical system cantilever array. The ABM mimics the tonotopy of the cochlea: frequency selectivity and mechanoelectric transduction. The fabricated ABM exhibits a clear tonotopy in an audible frequency range (2.92–12.6 kHz). Also, an animal model was used to verify the characteristics of the ABM as a front end for potential cochlear implant applications. For this, a signal processor was used to convert the piezoelectric output from the ABM to an electrical stimulus for auditory neurons. The electrical stimulus for auditory neurons was delivered through an implanted intra-cochlear electrode array. The amplitude of the electrical stimulus was modulated in the range of 0.15 to 3.5 V with incoming sound pressure levels (SPL) of 70.1 to 94.8 dB SPL. The electrical stimulus was used to elicit an electrically evoked auditory brainstem response (EABR) from deafened guinea pigs. EABRs were successfully measured and their magnitude increased upon application of acoustic stimuli from 75 to 95 dB SPL. The frequency selectivity of the ABM was estimated by measuring the magnitude of EABRs while applying sound pressure at the resonance and off-resonance frequencies of the corresponding cantilever of the selected channel. In this study, we demonstrated a novel piezoelectric ABM and verified its characteristics by measuring EABRs. PMID:26227924

  20. Underwater detection of tonal signals between 0.125 and 100 kHz by harbor seals (Phoca vitulina).

    PubMed

    Kastelein, Ronald A; Wensveen, Paul J; Hoek, Lean; Verboom, Willem C; Terhune, John M

    2009-02-01

    The underwater hearing sensitivities of two 1-year-old female harbor seals were quantified in a pool built for acoustic research, using a behavioral psychoacoustic technique. The animals were trained to respond when they detected an acoustic signal and not to respond when they did not (go/no-go response). Pure tones (0.125-0.25 kHz) and narrowband frequency modulated (tonal) signals (center frequencies 0.5-100 kHz) of 900 ms duration were tested. Thresholds at each frequency were measured using the up-down staircase method and defined as the stimulus level resulting in a 50% detection rate. The audiograms of the two seals did not differ statistically: both plots showed the typical mammalian U-shape, but with a wide and flat bottom. Maximum sensitivity (54 dB re 1 microPa, rms) occurred at 1 kHz. The frequency range of best hearing (within 10 dB of maximum sensitivity) was from 0.5 to 40 kHz (6(1/3) octaves). Higher hearing thresholds (indicating poorer sensitivity) were observed below 1 and above 40 kHz. Thresholds below 4 kHz were lower than those previously described for harbor seals, which demonstrates the importance of using quiet facilities, built specifically for acoustic research, for hearing studies in marine mammals. The results suggest that under unmasked conditions many anthropogenic noise sources and sounds from conspecifics are audible to harbor seals at greater ranges than formerly believed.

  1. A microelectromechanical system artificial basilar membrane based on a piezoelectric cantilever array and its characterization using an animal model

    NASA Astrophysics Data System (ADS)

    Jang, Jongmoon; Lee, Jangwoo; Woo, Seongyong; Sly, David J.; Campbell, Luke J.; Cho, Jin-Ho; O'Leary, Stephen J.; Park, Min-Hyun; Han, Sungmin; Choi, Ji-Wong; Hun Jang, Jeong; Choi, Hongsoo

    2015-07-01

    We proposed a piezoelectric artificial basilar membrane (ABM) composed of a microelectromechanical system cantilever array. The ABM mimics the tonotopy of the cochlea: frequency selectivity and mechanoelectric transduction. The fabricated ABM exhibits a clear tonotopy in an audible frequency range (2.92-12.6 kHz). Also, an animal model was used to verify the characteristics of the ABM as a front end for potential cochlear implant applications. For this, a signal processor was used to convert the piezoelectric output from the ABM to an electrical stimulus for auditory neurons. The electrical stimulus for auditory neurons was delivered through an implanted intra-cochlear electrode array. The amplitude of the electrical stimulus was modulated in the range of 0.15 to 3.5 V with incoming sound pressure levels (SPL) of 70.1 to 94.8 dB SPL. The electrical stimulus was used to elicit an electrically evoked auditory brainstem response (EABR) from deafened guinea pigs. EABRs were successfully measured and their magnitude increased upon application of acoustic stimuli from 75 to 95 dB SPL. The frequency selectivity of the ABM was estimated by measuring the magnitude of EABRs while applying sound pressure at the resonance and off-resonance frequencies of the corresponding cantilever of the selected channel. In this study, we demonstrated a novel piezoelectric ABM and verified its characteristics by measuring EABRs.

  2. Remote infrared audible signage (RIAS) pilot program report.

    DOT National Transportation Integrated Search

    2011-07-01

    The Remote Infrared Audible Sign Model Accessibility Program (RIAS MAP) is a program funded by the Federal Transit Administration (FTA) to evaluate the effectiveness of remote infrared audible sign systems in enabling persons with visual and cognitiv...

  3. Underwater localization of pure tones by harbor seals (Phoca vitulina).

    PubMed

    Bodson, Anaïs; Miersch, Lars; Dehnhardt, Guido

    2007-10-01

    The underwater sound localization acuity of harbor seals (Phoca vitulina) was measured in the horizontal plane. Minimum audible angles (MAAs) of pure tones were determined as a function of frequency from 0.2 to 16 kHz for two seals. Testing was conducted in a 10-m-diam underwater half circle using a right/left psychophysical procedure. The results indicate that for both harbor seals, MAAs were large at high frequencies (13.5 degrees and 17.4 degrees at 16 kHz), transitional at intermediate frequencies (9.6 degrees and 10.1 degrees at 4 kHz), and particularly small at low frequencies (3.2 degrees and 3.1 degrees at 0.2 kHz). Harbor seals seem to be able to utilize both binaural cues, interaural time differences (ITDs) and interaural intensity differences (IIDs), but a significant decrease in the sound localization acuity with increasing frequency suggests that IID cues may not be as robust as ITD cues under water. These results suggest that the harbor seal can be regarded as a low-frequency specialist. Additionally, to obtain a MAA more representative of the species, the horizontal underwater MAA of six adult harbor seals was measured at 2 kHz under identical conditions. The MAAs of the six animals ranged from 8.8 degrees to 11.7 degrees , resulting in a mean MAA of 10.3 degrees .

  4. Directional guidance from audible pedestrian signals for street crossing.

    PubMed

    Wall, Robert S; Ashmead, Daniel H; Bentzen, Billie Louise; Barlow, Janet

    2004-10-10

    Typical audible pedestrian signals indicate when the pedestrian walk interval is in effect but provide little, or even misleading information for directional alignment. In three experiments, blind and blindfolded sighted adults crossed a simulated crossing with recorded traffic noise to approximate street sounds. This was done to investigate how characteristics of signal presentation affected usefulness of the auditory signal for guiding crossing behaviour. Crossing was more accurate when signals came only from the far end of the crossing rather than the typical practice of presenting signals simultaneously from both ends. Alternating the signal between ends of the crossing was not helpful. Also, the customary practice of signalling two parallel crossings at the same time drew participants somewhat toward the opposite crossing. Providing a locator tone at the end of the crossing during the pedestrian clearance interval improved crossing accuracy. These findings provide a basis for designing audible pedestrian signals to enhance directional guidance. The principal findings were the same for blind and sighted participants and applied across a range of specific signals (e.g. chirps, clicks, voices).

  5. Hearing in alpacas (Vicugna pacos): audiogram, localization acuity, and use of binaural locus cues.

    PubMed

    Heffner, Rickye S; Koay, Gimseong; Heffner, Henry E

    2014-02-01

    Behavioral audiograms and sound localization abilities were determined for three alpacas (Vicugna pacos). Their hearing at a level of 60 dB sound pressure level (SPL) (re 20 μPa) extended from 40 Hz to 32.8 kHz, a range of 9.7 octaves. They were most sensitive at 8 kHz, with an average threshold of -0.5 dB SPL. The minimum audible angle around the midline for 100-ms broadband noise was 23°, indicating relatively poor localization acuity and potentially supporting the finding that animals with broad areas of best vision have poorer sound localization acuity. The alpacas were able to localize low-frequency pure tones, indicating that they can use the binaural phase cue, but they were unable to localize pure tones above the frequency of phase ambiguity, thus indicating complete inability to use the binaural intensity-difference cue. In contrast, the alpacas relied on their high-frequency hearing for pinna cues; they could discriminate front-back sound sources using 3-kHz high-pass noise, but not 3-kHz low-pass noise. These results are compared to those of other hoofed mammals and to mammals more generally.

  6. The Audible Pop from Thoracic Spine Thrust Manipulation and Its Relation to Short-Term Outcomes in Patients with Neck Pain

    PubMed Central

    Cleland, Joshua A.; Flynn, Timothy W.; Childs, John D.; Eberhart, Sarah

    2007-01-01

    Clinicians routinely consider the success of a thrust manipulation technique based on the presence or absence of an audible pop despite the lack of evidence suggesting that this pop is associated with improved outcomes. The purpose of this study was to determine the relationship between the number of audible pops with thoracic spinal manipulation and improvement in pain and function in patients with mechanical neck pain. In this prospective cohort study, 78 patients referred to physical therapy with mechanical neck pain underwent a standardized examination and thoracic spine manipulation treatment protocol. All patients were treated with a total of 6 thrust manipulation techniques directed to the thoracic spine followed by a basic cervical range of motion exercise. The treating clinician recorded the presence or absence of a pop during each manipulation. Outcomes were assessed at a 2–4 day follow-up with an 11-point numeric pain rating (NPRS), the Neck Disability Index, the patient Global Rating of Change (GROC), and measurements of cervical range of motion (CROM). The relationship between the number of pops and change scores for pain, disability, and CROM was first examined using Pearson correlation coefficients. Individuals were then categorized as having received ≤3 or >3 pops. Repeated measures analyses of variance were used to examine whether achievement of >3 pops resulted in improved outcome. Seventy-eight patients with a mean age of 42 (SD 11.3) years participated in the study. Pearson correlation coefficients revealed no significant correlation existed between the number of pops and outcomes with the exception of 3 of the 6 CROM measurements, which were inversely related. There was no significant interaction for group X time for any of the dependent measures (P>0.05). The odds ratio for patients experiencing dramatic improvement was in favor of the group experiencing ≤3 pops but this was not clinically meaningful (1.3: 95% CI 0.46, 3.7). The results of this analysis provide preliminary evidence for the hypothesis that there is no relationship between the number of audible pops during thoracic spine thrust manipulation and clinically meaningful improvements in pain, disability, or CROM in patients with mechanical neck pain. Additionally, a greater number of audible pops experienced was not associated with a dramatic improvement with manipulation treatment. PMID:19066662

  7. Locomotor effects of a low-frequency fire alarm on C57BL/6 male mice: a preliminary study.

    PubMed

    Povroznik, Jessica M; Faith, Robert E; Kessler, Matthew J; Ali, Frank N; Kosik, James; Prince, Stephen; Engler-Chiurazzi, Elizabeth B

    2017-12-01

    Maintaining appropriate acoustic conditions for animal welfare and data collection are crucial in biomedical research facilities. Negative impacts of disruptive sound are known and can include auditory damage, immune function changes, and behavioral alterations. One type of disruptive sound occurring in research facilities is that of fire alarms. To ameliorate this problem, many facilities have incorporated the use of low-frequency fire alarms that emit tones outside the rodent audible range. The impact of these devices has been assumed to be negligible. However, this has yet to be evaluated with controlled behavioral experiments. Thus, our objective was to investigate the impact of low-frequency fire alarm exposure on locomotor behavior in the open field, a test sensitive to acoustic stimuli disruption. Male mice were randomized to three alarm exposure groups (No-Alarm; Alarm-During; and Alarm-After) and placed in individual photobeam-activated locomotor chambers. The Alarm-During group displayed significantly reduced horizontal locomotion, with a trend towards reduced vertical locomotion. These data suggest that a low-frequency brief alarm tone can temporarily disrupt movement, a valuable insight should an alarm be deployed. Further, findings support close collaboration between researchers and institutional facility staff to ensure appropriate acoustic conditions are maintained, whenever possible, for research animals.

  8. Effects of degree and configuration of hearing loss on the contribution of high- and low-frequency speech information to bilateral speech understanding

    PubMed Central

    Hornsby, Benjamin W. Y.; Johnson, Earl E.; Picou, Erin

    2011-01-01

    Objectives The purpose of this study was to examine the effects of degree and configuration of hearing loss on the use of, and benefit from, information in amplified high- and low-frequency speech presented in background noise. Design Sixty-two adults with a wide range of high- and low-frequency sensorineural hearing loss (5–115+ dB HL) participated. To examine the contribution of speech information in different frequency regions, speech understanding in noise was assessed in multiple low- and high-pass filter conditions, as well as a band-pass (713–3534 Hz) and wideband (143–8976 Hz) condition. To increase audibility over a wide frequency range, speech and noise were amplified based on each individual’s hearing loss. A stepwise multiple linear regression approach was used to examine the contribution of several factors to 1) absolute performance in each filter condition and 2) the change in performance with the addition of amplified high- and low-frequency speech components. Results Results from the regression analysis showed that degree of hearing loss was the strongest predictor of absolute performance for low- and high-pass filtered speech materials. In addition, configuration of hearing loss affected both absolute performance for severely low-pass filtered speech and benefit from extending high-frequency (3534–8976 Hz) bandwidth. Specifically, individuals with steeply sloping high-frequency losses made better use of low-pass filtered speech information than individuals with similar low-frequency thresholds but less high-frequency loss. In contrast, given similar high-frequency thresholds, individuals with flat hearing losses received more benefit from extending high-frequency bandwidth than individuals with more sloping losses. Conclusions Consistent with previous work, benefit from speech information in a given frequency region generally decreases as degree of hearing loss in that frequency region increases. However, given a similar degree of loss, the configuration of hearing loss also affects the ability to use speech information in different frequency regions. Except for individuals with steeply sloping high-frequency losses, providing high-frequency amplification (3534–8976 Hz) had either a beneficial effect on, or did not significantly degrade, speech understanding. These findings highlight the importance of extended high-frequency amplification for listeners with a wide range of high-frequency hearing losses, when seeking to maximize intelligibility. PMID:21336138

  9. 33 CFR 86.05 - Sound signal intensity and range of audibility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... direction of the forward axis of the whistle and at a distance of 1 meter from it, a sound pressure level in... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Sound signal intensity and range... HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Whistles...

  10. In-Vivo Animation of Auditory-Language-Induced Gamma-Oscillations in Children with Intractable Focal Epilepsy

    PubMed Central

    Brown, Erik C.; Rothermel, Robert; Nishida, Masaaki; Juhász, Csaba; Muzik, Otto; Hoechstetter, Karsten; Sood, Sandeep; Chugani, Harry T.; Asano, Eishi

    2008-01-01

    We determined if high-frequency gamma-oscillations (50- to 150-Hz) were induced by simple auditory communication over the language network areas in children with focal epilepsy. Four children (ages: 7, 9, 10 and 16 years) with intractable left-hemispheric focal epilepsy underwent extraoperative electrocorticography (ECoG) as well as language mapping using neurostimulation and auditory-language-induced gamma-oscillations on ECoG. The audible communication was recorded concurrently and integrated with ECoG recording to allow for accurate time-lock upon ECoG analysis. In three children, who successfully completed the auditory-language task, high-frequency gamma-augmentation sequentially involved: i) the posterior superior temporal gyrus when listening to the question, ii) the posterior lateral temporal region and the posterior frontal region in the time interval between question completion and the patient’s vocalization, and iii) the pre- and post-central gyri immediately preceding and during the patient’s vocalization. The youngest child, with attention deficits, failed to cooperate during the auditory-language task, and high-frequency gamma-augmentation was noted only in the posterior superior temporal gyrus when audible questions were given. The size of language areas suggested by statistically-significant high-frequency gamma-augmentation was larger than that defined by neurostimulation. The present method can provide in-vivo imaging of electrophysiological activities over the language network areas during language processes. Further studies are warranted to determine whether recording of language-induced gamma-oscillations can supplement language mapping using neurostimulation in presurgical evaluation of children with focal epilepsy. PMID:18455440

  11. 33 CFR 86.05 - Sound signal intensity and range of audibility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... average background noise level at the listening posts (taken to be 68 dB in the octave band centered on... regarded as typical but under conditions of strong wind or high ambient noise level at the listening post...

  12. 49 CFR 236.513 - Audible indicator.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.513 Audible indicator. (a) The automatic cab signal... control system shall have a distinctive sound and be clearly audible throughout the cab under all...

  13. 49 CFR 236.513 - Audible indicator.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.513 Audible indicator. (a) The automatic cab signal... control system shall have a distinctive sound and be clearly audible throughout the cab under all...

  14. Noise in a Laboratory Animal Facility from the Human and Mouse Perspectives

    PubMed Central

    Reynolds, Randall P; Kinard, Will L; Degraff, Jesse J; Leverage, Ned; Norton, John N

    2010-01-01

    The current study was performed to understand the level of sound produced by ventilated racks, animal transfer stations, and construction equipment that mice in ventilated cages hear relative to what humans would hear in the same environment. Although the ventilated rack and animal transfer station both produced sound pressure levels above the ambient level within the human hearing range, the sound pressure levels within the mouse hearing range did not increase above ambient noise from either noise source. When various types of construction equipment were used 3 ft from the ventilated rack, the sound pressure level within the mouse hearing range was increased but to a lesser degree for each implement than were the sound pressure levels within the human hearing range. At more distant locations within the animal facility, sound pressure levels from the large jackhammer within the mouse hearing range decreased much more rapidly than did those in the human hearing range, indicating that less of the sound is perceived by mice than by humans. The relatively high proportion of low-frequency sound produced by the shot blaster, used without the metal shot that it normally uses to clean concrete, increased the sound pressure level above the ambient level for humans but did not increase sound pressure levels above ambient noise for mice at locations greater than 3 ft from inside of the cage, where sound was measured. This study demonstrates that sound clearly audible to humans in the animal facility may be perceived to a lesser degree or not at all by mice, because of the frequency content of the sound. PMID:20858361

  15. Design and Validation of a Breathing Detection System for Scuba Divers.

    PubMed

    Altepe, Corentin; Egi, S Murat; Ozyigit, Tamer; Sinoplu, D Ruzgar; Marroni, Alessandro; Pierleoni, Paola

    2017-06-09

    Drowning is the major cause of death in self-contained underwater breathing apparatus (SCUBA) diving. This study proposes an embedded system with a live and light-weight algorithm which detects the breathing of divers through the analysis of the intermediate pressure (IP) signal of the SCUBA regulator. A system composed mainly of two pressure sensors and a low-power microcontroller was designed and programmed to record the pressure sensors signals and provide alarms in absence of breathing. An algorithm was developed to analyze the signals and identify inhalation events of the diver. A waterproof case was built to accommodate the system and was tested up to a depth of 25 m in a pressure chamber. To validate the system in the real environment, a series of dives with two different types of workload requiring different ranges of breathing frequencies were planned. Eight professional SCUBA divers volunteered to dive with the system to collect their IP data in order to participate to validation trials. The subjects underwent two dives, each of 52 min on average and a maximum depth of 7 m. The algorithm was optimized for the collected dataset and proved a sensitivity of inhalation detection of 97.5% and a total number of 275 false positives (FP) over a total recording time of 13.9 h. The detection algorithm presents a maximum delay of 5.2 s and requires only 800 bytes of random-access memory (RAM). The results were compared against the analysis of video records of the dives by two blinded observers and proved a sensitivity of 97.6% on the data set. The design includes a buzzer to provide audible alarms to accompanying dive buddies which will be triggered in case of degraded health conditions such as near drowning (absence of breathing), hyperventilation (breathing frequency too high) and skip-breathing (breathing frequency too low) measured by the improper breathing frequency. The system also measures the IP at rest before the dive and indicates with flashing light-emitting diodes and audible alarm the regulator malfunctions due to high or low IP that may cause fatal accidents during the dive by preventing natural breathing. It is also planned to relay the alarm signal to underwater and surface rescue authorities by means of acoustic communication.

  16. Multichannel Compression, Temporal Cues, and Audibility.

    ERIC Educational Resources Information Center

    Souza, Pamela E.; Turner, Christopher W.

    1998-01-01

    The effect of the reduction of the temporal envelope produced by multichannel compression on recognition was examined in 16 listeners with hearing loss, with particular focus on audibility of the speech signal. Multichannel compression improved speech recognition when superior audibility was provided by a two-channel compression system over linear…

  17. Bendable Electro-Acoustic Transducer Fabricated Utilizing Frequency Dispersion of Elastic Modulus

    NASA Astrophysics Data System (ADS)

    Miyoshi, Tetsu; Ohga, Juro

    2013-09-01

    To realize the speaker diaphragm that can be united with a flexible display without deteriorating lightweight properties and flexibility, a novel bendable electro-acoustic transducer (BEAT) based on 0-3-type piezoelectric composites has been developed. To overcome the trade-off between flexibility and the transmission efficiency of vibration energy, a viscoelastic polymer that has local maximum points in the loss factor as well as large frequency dispersion in the storage modulus near room temperature was employed as the matrix of the piezoelectric composite layer. Against the comparatively slow (10 Hz or less) deformation from the outside, the viscoelastic matrix is viscous enough to prevent cracking and delamination. On the other hand, in the audible range (20 Hz to 20 kHz), the matrix is elastic enough to transmit piezoelectric vibration energy, maintaining a moderately large loss factor as well as a high sound velocity. For the first time, we successfully demonstrated a rollable speaker that can continue to generate a high-quality sound while being rolled and unrolled repeatedly onto a cylinder with a curvature radius of 4 mm.

  18. DIRECT NUMERICAL SIMULATION OF TRANSITIONAL FLOW IN A STENOSED CAROTID BIFURCATION

    PubMed Central

    Lee, Seung E.; Lee, Sang-Wook; Fischer, Paul F.; Bassiouny, Hisham S.; Loth, Francis

    2008-01-01

    The blood flow dynamics of a stenosed, subject-specific, carotid bifurcation were numerically simulated using the spectral element method. Pulsatile inlet conditions were based on in vivo color Doppler ultrasound measurements of blood velocity. The results demonstrated the transitional or weakly turbulent state of the blood flow, which featured rapid velocity and pressure fluctuations in the post-stenotic region of the internal carotid artery during systole and laminar flow during diastole. High-frequency vortex shedding was greatest downstream of the stenosis during the deceleration phase of systole. Velocity fluctuations had a frequency within the audible range of 100–300 Hz. Instantaneous wall shear stress within the stenosis was relatively high during systole (~25-45 Pa) compared to that in a healthy carotid. In addition, high spatial gradients of wall shear stress were present due to flow separation on the inner wall. Oscillatory flow reversal and low pressure were observed distal to the stenosis in the internal carotid artery. This study predicts the complex flow field, the turbulence levels and the distribution of the biomechanical stresses present in vivo within a stenosed carotid artery. PMID:18656199

  19. New Principles in Weapons.

    DTIC Science & Technology

    1980-10-10

    mishaps. The oscillation frequency of infra - sonic waves is lower than 16 times per second and they are in- audible. In the air, their disseminating speed...chemistry methods to injure living targets. For example, the production of immense ultrasonic waves or infrasonic waves can cause headaches, vomiting...human body. Foreign statements, based on research and experiments carried out over a long period of time, report that the use of infrasonic wave weapons

  20. Can temporal fine structure represent the fundamental frequency of unresolved harmonics?

    PubMed

    Oxenham, Andrew J; Micheyl, Christophe; Keebler, Michael V

    2009-04-01

    At least two modes of pitch perception exist: in one, the fundamental frequency (F0) of harmonic complex tones is estimated using the temporal fine structure (TFS) of individual low-order resolved harmonics; in the other, F0 is derived from the temporal envelope of high-order unresolved harmonics that interact in the auditory periphery. Pitch is typically more accurate in the former than in the latter mode. Another possibility is that pitch can sometimes be coded via the TFS from unresolved harmonics. A recent study supporting this third possibility [Moore et al. (2006a). J. Acoust. Soc. Am. 119, 480-490] based its conclusion on a condition where phase interaction effects (implying unresolved harmonics) accompanied accurate F0 discrimination (implying TFS processing). The present study tests whether these results were influenced by audible distortion products. Experiment 1 replicated the original results, obtained using a low-level background noise. However, experiments 2-4 found no evidence for the use of TFS cues with unresolved harmonics when the background noise level was raised, or the stimulus level was lowered, to render distortion inaudible. Experiment 5 measured the presence and phase dependence of audible distortion products. The results provide no evidence that TFS cues are used to code the F0 of unresolved harmonics.

  1. Making Thinking Audible and Visible via Cooperative Learning

    ERIC Educational Resources Information Center

    Jacobs, George M.; Wang, Aili; Li, Xishuang; Xie, Yongye

    2008-01-01

    This chapter begins with a section that describes cooperative learning and explains eight cooperative learning principles. The second section looks briefly at why making thinking audible and visible enriches students' thinking. Making thinking audible means that teachers and students speak out what is going through their minds as they do a task,…

  2. Methods and Applications of the Audibility Index in Hearing Aid Selection and Fitting

    PubMed Central

    Amlani, Amyn M.; Punch, Jerry L.; Ching, Teresa Y. C.

    2002-01-01

    During the first half of the 20th century, communications engineers at Bell Telephone Laboratories developed the articulation model for predicting speech intelligibility transmitted through different telecommunication devices under varying electroacoustic conditions. The profession of audiology adopted this model and its quantitative aspects, known as the Articulation Index and Speech Intelligibility Index, and applied these indices to the prediction of unaided and aided speech intelligibility in hearing-impaired listeners. Over time, the calculation methods of these indices—referred to collectively in this paper as the Audibility Index—have been continually refined and simplified for clinical use. This article provides (1) an overview of the basic principles and the calculation methods of the Audibility Index, the Speech Transmission Index and related indices, as well as the Speech Recognition Sensitivity Model, (2) a review of the literature on using the Audibility Index to predict speech intelligibility of hearing-impaired listeners, (3) a review of the literature on the applicability of the Audibility Index to the selection and fitting of hearing aids, and (4) a discussion of future scientific needs and clinical applications of the Audibility Index. PMID:25425917

  3. The effect of a movie soundtrack on auditory event-related potentials in children, adolescents, and adults.

    PubMed

    Mahajan, Yatin; McArthur, Genevieve

    2011-05-01

    To determine if an audible movie soundtrack has a degrading effect on the auditory P1, N1, P2, N2, or mismatch negativity (MMN) event-related potentials (ERPs) in children, adolescents, or adults. The auditory ERPs of 36 children, 32 young adolescents, 19 older adolescents, and 10 adults were measured while they watched a movie in two conditions: with an audible soundtrack and with a silent soundtrack. In children and adolescents, the audible movie soundtrack had a significant impact on amplitude, latency or split-half reliability of the N1, P2, N2, and MMN ERPs. The audible soundtrack had minimal impact on the auditory ERPs of adults. These findings challenge previous claims that an audible soundtrack does not degrade the auditory ERPs of children. Further, the reliability of the MMN is poorer than P1, N1, P2, and N2 peaks in both sound-off and sound-on conditions. Researchers should be cautious about using an audible movie soundtrack when measuring auditory ERPs in younger listeners. Copyright © 2010 International Federation of Clinical Neurophysiology. All rights reserved.

  4. Acoustic characteristics of ultrasonic coded transmitters for fishery applications: could marine mammals hear them?

    PubMed

    Bowles, Ann E; Denes, Samuel L; Shane, Michael A

    2010-11-01

    Ultrasonic coded transmitters (UCTs) producing frequencies of 69-83 kHz are used increasingly to track fish and invertebrates in coastal and estuarine waters. To address concerns that they might be audible to marine mammals, acoustic properties of UCTs were measured off Mission Beach, San Diego, and at the U.S. Navy TRANSDEC facility. A regression model fitted to VEMCO UCT data yielded an estimated source level of 147 dB re 1 μPa SPL @ 1 m and spreading constant of 14.0. Based on TRANSDEC measurements, five VEMCO 69 kHz UCTs had source levels ranging from 146 to 149 dB re 1 μPa SPL @ 1 m. Five Sonotronics UCTs (69 kHz and 83 kHz) had source levels ranging from 129 to 137 dB re 1 μPa SPL @ 1 m. Transmitter directionality ranged from 3.9 to 18.2 dB. Based on propagation models and published data on marine mammal auditory psychophysics, harbor seals potentially could detect the VEMCO 69 kHz UCTs at ranges between 19 and >200 m, while odontocetes potentially could detect them at much greater ranges. California sea lions were not expected to detect any of the tested UCTs at useful ranges.

  5. Comparing phase-sensitive and phase-insensitive echolocation target images using a monaural audible sonar.

    PubMed

    Kuc, Roman

    2018-04-01

    This paper describes phase-sensitive and phase-insensitive processing of monaural echolocation waveforms to generate target maps. Composite waveforms containing both the emission and echoes are processed to estimate the target impulse response using an audible sonar. Phase-sensitive processing yields the composite signal envelope, while phase-insensitive processing that starts with the composite waveform power spectrum yields the envelope of the autocorrelation function. Analysis and experimental verification show that multiple echoes form an autocorrelation function that produces near-range phantom-reflector artifacts. These artifacts interfere with true target echoes when the first true echo occurs at a time that is less than the total duration of the target echoes. Initial comparison of phase-sensitive and phase-insensitive maps indicates that both display important target features, indicating that phase is not vital. A closer comparison illustrates the improved resolution of phase-sensitive processing, the near-range phantom-reflectors produced by phase-insensitive processing, and echo interference and multiple reflection artifacts that were independent of the processing.

  6. Meteor fireball sounds identified

    NASA Technical Reports Server (NTRS)

    Keay, Colin

    1992-01-01

    Sounds heard simultaneously with the flight of large meteor fireballs are electrical in origin. Confirmation that Extra/Very Low Frequency (ELF/VLF) electromagnetic radiation is produced by the fireball was obtained by Japanese researchers. Although the generation mechanism is not fully understood, studies of the Meteorite Observation and Recovery Project (MORP) and other fireball data indicate that interaction with the atmosphere is definitely responsible and the cut-off magnitude of -9 found for sustained electrophonic sounds is supported by theory. Brief bursts of ELF/VLF radiation may accompany flares or explosions of smaller fireballs, producing transient sounds near favorably placed observers. Laboratory studies show that mundane physical objects can respond to electrical excitation and produce audible sounds. Reports of electrophonic sounds should no longer be discarded. A catalog of over 300 reports relating to electrophonic phenomena associated with meteor fireballs, aurorae, and lightning was assembled. Many other reports have been cataloged in Russian. These may assist the full solution of the similar long-standing and contentious mystery of audible auroral displays.

  7. High-speed imaging, acoustic features, and aeroacoustic computations of jet noise from Strombolian (and Vulcanian) explosions

    NASA Astrophysics Data System (ADS)

    Taddeucci, J.; Sesterhenn, J.; Scarlato, P.; Stampka, K.; Del Bello, E.; Pena Fernandez, J. J.; Gaudin, D.

    2014-05-01

    High-speed imaging of explosive eruptions at Stromboli (Italy), Fuego (Guatemala), and Yasur (Vanuatu) volcanoes allowed visualization of pressure waves from seconds-long explosions. From the explosion jets, waves radiate with variable geometry, timing, and apparent direction and velocity. Both the explosion jets and their wave fields are replicated well by numerical simulations of supersonic jets impulsively released from a pressurized vessel. The scaled acoustic signal from one explosion at Stromboli displays a frequency pattern with an excellent match to those from the simulated jets. We conclude that both the observed waves and the audible sound from the explosions are jet noise, i.e., the typical acoustic field radiating from high-velocity jets. Volcanic jet noise was previously quantified only in the infrasonic emissions from large, sub-Plinian to Plinian eruptions. Our combined approach allows us to define the spatial and temporal evolution of audible jet noise from supersonic jets in small-scale volcanic eruptions.

  8. Low power adder based auditory filter architecture.

    PubMed

    Rahiman, P F Khaleelur; Jayanthi, V S

    2014-01-01

    Cochlea devices are powered up with the help of batteries and they should possess long working life to avoid replacing of devices at regular interval of years. Hence the devices with low power consumptions are required. In cochlea devices there are numerous filters, each responsible for frequency variant signals, which helps in identifying speech signals of different audible range. In this paper, multiplierless lookup table (LUT) based auditory filter is implemented. Power aware adder architectures are utilized to add the output samples of the LUT, available at every clock cycle. The design is developed and modeled using Verilog HDL, simulated using Mentor Graphics Model-Sim Simulator, and synthesized using Synopsys Design Compiler tool. The design was mapped to TSMC 65 nm technological node. The standard ASIC design methodology has been adapted to carry out the power analysis. The proposed FIR filter architecture has reduced the leakage power by 15% and increased its performance by 2.76%.

  9. Overview of an Indoor Sonic Boom Simulator at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Klos, Jacob

    2012-01-01

    A facility has been constructed at NASA Langley Research Center to simulate the soundscape inside residential houses that are exposed to environmental noise from aircraft. This controllable indoor listening environment, the Interior Effects Room, enables systematic study of parameters that affect psychoacoustic response. The single-room facility, built using typical residential construction methods and materials, is surrounded on adjacent sides by two arrays of loudspeakers in close proximity to the exterior walls. The arrays, containing 52 subwoofers and 52 mid-range speakers, have a usable bandwidth of 3 Hz to 5 kHz and sufficient output to allow study of sonic boom noise. In addition to these exterior arrays, satellite speakers placed inside the room are used to augment the transmitted sound with rattle and other audible contact ]induced noise that can result from low frequency excitation of a residential house. The layout of the facility, operational characteristics, acoustic characteristics and equalization approaches are summarized.

  10. PT-SAFE: a software tool for development and annunciation of medical audible alarms.

    PubMed

    Bennett, Christopher L; McNeer, Richard R

    2012-03-01

    Recent reports by The Joint Commission as well as the Anesthesia Patient Safety Foundation have indicated that medical audible alarm effectiveness needs to be improved. Several recent studies have explored various approaches to improving the audible alarms, motivating the authors to develop real-time software capable of comparing such alarms. We sought to devise software that would allow for the development of a variety of audible alarm designs that could also integrate into existing operating room equipment configurations. The software is meant to be used as a tool for alarm researchers to quickly evaluate novel alarm designs. A software tool was developed for the purpose of creating and annunciating audible alarms. The alarms consisted of annunciators that were mapped to vital sign data received from a patient monitor. An object-oriented approach to software design was used to create a tool that is flexible and modular at run-time, can annunciate wave-files from disk, and can be programmed with MATLAB by the user to create custom alarm algorithms. The software was tested in a simulated operating room to measure technical performance and to validate the time-to-annunciation against existing equipment alarms. The software tool showed efficacy in a simulated operating room environment by providing alarm annunciation in response to physiologic and ventilator signals generated by a human patient simulator, on average 6.2 seconds faster than existing equipment alarms. Performance analysis showed that the software was capable of supporting up to 15 audible alarms on a mid-grade laptop computer before audio dropouts occurred. These results suggest that this software tool provides a foundation for rapidly staging multiple audible alarm sets from the laboratory to a simulation environment for the purpose of evaluating novel alarm designs, thus producing valuable findings for medical audible alarm standardization.

  11. Dissecting auditory verbal hallucinations into two components: audibility (Gedankenlautwerden) and alienation (thought insertion).

    PubMed

    Sommer, Iris E; Selten, Jean-Paul; Diederen, Kelly M; Blom, Jan Dirk

    2010-01-01

    This study proposes a theoretical framework which dissects auditory verbal hallucinations (AVH) into 2 essential components: audibility and alienation. Audibility, the perceptual aspect of AVH, may result from a disinhibition of the auditory cortex in response to self-generated speech. In isolation, this aspect leads to audible thoughts: Gedankenlautwerden. The second component is alienation, which is the failure to recognize the content of AVH as self-generated. This failure may be related to the fact that cerebral activity associated with AVH is predominantly present in the speech production area of the right hemisphere. Since normal inner speech is derived from the left speech area, an aberrant source may lead to confusion about the origin of the language fragments. When alienation is not accompanied by audibility, it will result in the experience of thought insertion. The 2 hypothesized components are illustrated using case vignettes. Copyright 2010 S. Karger AG, Basel.

  12. Reconfigurable Auditory-Visual Display

    NASA Technical Reports Server (NTRS)

    Begault, Durand R. (Inventor); Anderson, Mark R. (Inventor); McClain, Bryan (Inventor); Miller, Joel D. (Inventor)

    2008-01-01

    System and method for visual and audible communication between a central operator and N mobile communicators (N greater than or equal to 2), including an operator transceiver and interface, configured to receive and display, for the operator, visually perceptible and audibly perceptible signals from each of the mobile communicators. The interface (1) presents an audible signal from each communicator as if the audible signal is received from a different location relative to the operator and (2) allows the operator to select, to assign priority to, and to display, the visual signals and the audible signals received from a specified communicator. Each communicator has an associated signal transmitter that is configured to transmit at least one of the visual signals and the audio signal associated with the communicator, where at least one of the signal transmitters includes at least one sensor that senses and transmits a sensor value representing a selected environmental or physiological parameter associated with the communicator.

  13. Integrating cognitive and peripheral factors in predicting hearing-aid processing effectiveness

    PubMed Central

    Kates, James M.; Arehart, Kathryn H.; Souza, Pamela E.

    2013-01-01

    Individual factors beyond the audiogram, such as age and cognitive abilities, can influence speech intelligibility and speech quality judgments. This paper develops a neural network framework for combining multiple subject factors into a single model that predicts speech intelligibility and quality for a nonlinear hearing-aid processing strategy. The nonlinear processing approach used in the paper is frequency compression, which is intended to improve the audibility of high-frequency speech sounds by shifting them to lower frequency regions where listeners with high-frequency loss have better hearing thresholds. An ensemble averaging approach is used for the neural network to avoid the problems associated with overfitting. Models are developed for two subject groups, one having nearly normal hearing and the other mild-to-moderate sloping losses. PMID:25669257

  14. Tonal response on the stairway of the main pyramid at La Ciudadela, Teotihuacan archaeological site

    NASA Astrophysics Data System (ADS)

    Beristain, Sergio; Coss, Cecilia; Aquino, Gabriela; Negrete, Jose; Lizana, Pablo

    2002-11-01

    This paper presents new research on the very interesting audible effects produced by the stairways of many archaeological sites in Mexico. This investigation was made at the main stairway of the pyramid at La Ciudadela, Teotihuacan archaeological site. The effect previously studied was a chirped echo reflected from the stairway at normal incidence, which resembles the singing of the Quetzal. Now it is presented with the impulsive sound source and the listeners located at different angles, where apart from the characteristic chirped sound, several musical notes could be obtained and identified, covering a range of at least one half an octave. This evaluation was made at the site, where the effect is clearly audible, and it is supported with simple mathematics.

  15. Modeling the directivity of parametric loudspeaker

    NASA Astrophysics Data System (ADS)

    Shi, Chuang; Gan, Woon-Seng

    2012-09-01

    The emerging applications of the parametric loudspeaker, such as 3D audio, demands accurate directivity control at the audible frequency (i.e. the difference frequency). Though the delay-and-sum beamforming has been proven adequate to adjust the steering angles of the parametric loudspeaker, accurate prediction of the mainlobe and sidelobes remains a challenging problem. It is mainly because of the approximations that are used to derive the directivity of the difference frequency from the directivity of the primary frequency, and the mismatches between the theoretical directivity and the measured directivity caused by system errors incurred at different stages of the implementation. In this paper, we propose a directivity model of the parametric loudspeaker. The directivity model consists of two tuning vectors corresponding to the spacing error and the weight error for the primary frequency. The directivity model adopts a modified form of the product directivity principle for the difference frequency to further improve the modeling accuracy.

  16. En route noise of turboprop aircraft and their acceptability: Report of tests

    NASA Technical Reports Server (NTRS)

    Held, Wolf

    1990-01-01

    The development of propfan-powered aircraft has been observed with great interest. It is obvious that during cruising flight, the aircraft powerplant (propellers) cause a noise clearly perceivable on the ground. It is the audible frequency spectrum of the propfan powerplants relative to the high tip speeds that presents the problem. A flight test was conducted on 30 April, 1989 at the Frankfurt Airport. Results of the test flight are present.

  17. Evaluating signal-to-noise ratios, loudness, and related measures as indicators of airborne sound insulation.

    PubMed

    Park, H K; Bradley, J S

    2009-09-01

    Subjective ratings of the audibility, annoyance, and loudness of music and speech sounds transmitted through 20 different simulated walls were used to identify better single number ratings of airborne sound insulation. The first part of this research considered standard measures such as the sound transmission class the weighted sound reduction index (R(w)) and variations of these measures [H. K. Park and J. S. Bradley, J. Acoust. Soc. Am. 126, 208-219 (2009)]. This paper considers a number of other measures including signal-to-noise ratios related to the intelligibility of speech and measures related to the loudness of sounds. An exploration of the importance of the included frequencies showed that the optimum ranges of included frequencies were different for speech and music sounds. Measures related to speech intelligibility were useful indicators of responses to speech sounds but were not as successful for music sounds. A-weighted level differences, signal-to-noise ratios and an A-weighted sound transmission loss measure were good predictors of responses when the included frequencies were optimized for each type of sound. The addition of new spectrum adaptation terms to R(w) values were found to be the most practical approach for achieving more accurate predictions of subjective ratings of transmitted speech and music sounds.

  18. [Characteristics of infrasound and its influence on workers in working environment of certain thermoelectricity works and department].

    PubMed

    Dang, Wei-Min; Wang, Sheng; Tian, Shi-Xiu; Zhao, Quan-Hong; Chen, Bing; Sun, Fei; He, Li-Hua; Zou, Zhi-Fang; Guo, Zhi-Bin; Ma, Wen-Jun

    2008-12-01

    To study the characteristics of infrasound and its effects on the workers at power plants. The audible noise and infrasound in three thermoelectricity plants were measured and by using Symptom Checklist 90 (SCL-90), the subjective sensation, and the physiological indices were compared between exposed workers and controls. The infrasound levels were different at different measure sites of the three thermoelectricity works ranging from 40 to 98 dB. There was still 40 approximately 80 dB infrasound even when the soot blower stopped running. Different apparatus produced different infrasound levels with the highest ranging from 62 to 115 dB. A single frequency (16 Hz) infrasound was produced in certain department during working hour with sound pressure levels of 110 to 120 dB, but the audible noise sound pressure level was less than 70 dB. There was no significant difference in the indices representing vision fatigue and neurobehaviour function between exposed workers and controls. Workers at certain department experienced evident subjective sensation of neurobehavioral dysfunction, and the scores of somatization, depression, hostility, phobic anxiety, and psychotism in the SCL-90 were significantly higher in the exposed group than in the control and the norm in China (P < 0.05). Infrasound is ubiquitous in the working environment, but usually, the noise levels are less than 120 dB. In some special production department, there is persistent infrasound above 110 to 120 dB. No obvious health effects are found among those who are exposed to infrasound below 100 dB. However, the workers who are chronically exposed to infrasound above 110 to 120 dB present notable subjective sensation of autonomic neurobehavioral dysfunction, and their psychological health status is not as good as those in the control and those in the domestic normal pattern.

  19. Audibility and visual biasing in speech perception

    NASA Astrophysics Data System (ADS)

    Clement, Bart Richard

    Although speech perception has been considered a predominantly auditory phenomenon, large benefits from vision in degraded acoustic conditions suggest integration of audition and vision. More direct evidence of this comes from studies of audiovisual disparity that demonstrate vision can bias and even dominate perception (McGurk & MacDonald, 1976). It has been observed that hearing-impaired listeners demonstrate more visual biasing than normally hearing listeners (Walden et al., 1990). It is argued here that stimulus audibility must be equated across groups before true differences can be established. In the present investigation, effects of visual biasing on perception were examined as audibility was degraded for 12 young normally hearing listeners. Biasing was determined by quantifying the degree to which listener identification functions for a single synthetic auditory /ba-da-ga/ continuum changed across two conditions: (1)an auditory-only listening condition; and (2)an auditory-visual condition in which every item of the continuum was synchronized with visual articulations of the consonant-vowel (CV) tokens /ba/ and /ga/, as spoken by each of two talkers. Audibility was altered by presenting the conditions in quiet and in noise at each of three signal-to- noise (S/N) ratios. For the visual-/ba/ context, large effects of audibility were found. As audibility decreased, visual biasing increased. A large talker effect also was found, with one talker eliciting more biasing than the other. An independent lipreading measure demonstrated that this talker was more visually intelligible than the other. For the visual-/ga/ context, audibility and talker effects were less robust, possibly obscured by strong listener effects, which were characterized by marked differences in perceptual processing patterns among participants. Some demonstrated substantial biasing whereas others demonstrated little, indicating a strong reliance on audition even in severely degraded acoustic conditions. Listener effects were not correlated with lipreading performance. The large effect of audibility suggests that conclusions regarding an increased reliance on vision among hearing- impaired listeners were premature, and that accurate comparisons only can be made after equating audibility. Further, if after such control, individual hearing- impaired listeners demonstrate the processing differences that were demonstrated in the present investigation, then these findings have the potential to impact aural rehabilitation strategies.

  20. Seeing Chemistry through Sound: A Submersible Audible Light Sensor for Observing Chemical Reactions for Students Who Are Blind or Visually Impaired

    ERIC Educational Resources Information Center

    Supalo, Cary A.; Kreuter, Rodney A.; Musser, Aaron; Han, Josh; Briody, Erika; McArtor, Chip; Gregory, Kyle; Mallouk, Thomas E.

    2006-01-01

    In order to enable students who are blind and visually impaired to observe chemical changes in solutions, a hand-held device was designed to output light intensity as an audible tone. The submersible audible light sensor (SALS) creates an audio signal by which one can observe reactions in a solution in real time, using standard laboratory…

  1. Audible handheld Doppler ultrasound determines reliable and inexpensive exclusion of significant peripheral arterial disease.

    PubMed

    Alavi, Afsaneh; Sibbald, R Gary; Nabavizadeh, Reza; Valaei, Farnaz; Coutts, Pat; Mayer, Dieter

    2015-12-01

    To determine the accuracy of audible arterial foot signals with an audible handheld Doppler ultrasound for identification of significant peripheral arterial disease as a simple, quick, and readily available bedside screening tool. Two hundred consecutive patients referred to an interprofessional wound care clinic underwent audible handheld Doppler ultrasound of both legs. As a control and comparator, a formal bilateral lower leg vascular study including the calculation of Ankle Brachial Pressure Index and toe pressure (TP) was performed at the vascular lab. Diagnostic reliability of audible handheld Doppler ultrasound was calculated versus Ankle Brachial Pressure Index as the gold standard test. A sensitivity of 42.8%, a specificity of 97.5%, negative predictive value of 94.10%, positive predictive value of 65.22%, positive likelihood ratio of 17.52, and negative likelihood ratio of 0.59. The univariable logistic regression model had an area under the curve of 0.78. There was a statistically significant difference at the 5% level between univariable and multivariable area under the curves of the dorsalis pedis and posterior tibial models (p < 0.001). Audible handheld Doppler ultrasound proved to be a reliable, simple, rapid, and inexpensive bedside exclusion test of peripheral arterial disease in diabetic and nondiabetic patients. © The Author(s) 2015.

  2. Detection Rates of Cortical Auditory Evoked Potentials at Different Sensation Levels in Infants with Sensory/Neural Hearing Loss and Auditory Neuropathy Spectrum Disorder

    PubMed Central

    Gardner-Berry, Kirsty; Chang, Hsiuwen; Ching, Teresa Y. C.; Hou, Sanna

    2016-01-01

    With the introduction of newborn hearing screening, infants are being diagnosed with hearing loss during the first few months of life. For infants with a sensory/neural hearing loss (SNHL), the audiogram can be estimated objectively using auditory brainstem response (ABR) testing and hearing aids prescribed accordingly. However, for infants with auditory neuropathy spectrum disorder (ANSD) due to the abnormal/absent ABR waveforms, alternative measures of auditory function are needed to assess the need for amplification and evaluate whether aided benefit has been achieved. Cortical auditory evoked potentials (CAEPs) are used to assess aided benefit in infants with hearing loss; however, there is insufficient information regarding the relationship between stimulus audibility and CAEP detection rates. It is also not clear whether CAEP detection rates differ between infants with SNHL and infants with ANSD. This study involved retrospective collection of CAEP, hearing threshold, and hearing aid gain data to investigate the relationship between stimulus audibility and CAEP detection rates. The results demonstrate that increases in stimulus audibility result in an increase in detection rate. For the same range of sensation levels, there was no difference in the detection rates between infants with SNHL and ANSD. PMID:27587922

  3. Perfect absorption of low-frequency sound waves by critically coupled subwavelength resonant system

    NASA Astrophysics Data System (ADS)

    Long, Houyou; Cheng, Ying; Tao, Jiancheng; Liu, Xiaojun

    2017-01-01

    The perfect absorption (PA) for low-frequency audible sound waves has been achieved by critically coupling the inherent loss factor to the inherent leakage factor of a system, which is constructed by attaching a deep-subwavelength lossy resonant plate (LRP) to a backed rigid wall closely. We have certified it by using the graphical method in the complex frequency plane. By coupling the LRP to an air cavity in front of the rigid wall, the high efficient (>80%) low-frequency broadband absorption is obtained from 99.1 Hz to 294.8 Hz. Here, the thickness of LRP is only 1/13.5 of the relevant wavelength at 294.8 Hz. The impedance analyses further demonstrate that the impedances are perfectly matched between the system and the surrounding background medium at PA.

  4. Audible vision for the blind and visually impaired in indoor open spaces.

    PubMed

    Yu, Xunyi; Ganz, Aura

    2012-01-01

    In this paper we introduce Audible Vision, a system that can help blind and visually impaired users navigate in large indoor open spaces. The system uses computer vision to estimate the location and orientation of the user, and enables the user to perceive his/her relative position to a landmark through 3D audio. Testing shows that Audible Vision can work reliably in real-life ever-changing environment crowded with people.

  5. Sub-Audible Speech Recognition Based upon Electromyographic Signals

    NASA Technical Reports Server (NTRS)

    Jorgensen, Charles C. (Inventor); Agabon, Shane T. (Inventor); Lee, Diana D. (Inventor)

    2012-01-01

    Method and system for processing and identifying a sub-audible signal formed by a source of sub-audible sounds. Sequences of samples of sub-audible sound patterns ("SASPs") for known words/phrases in a selected database are received for overlapping time intervals, and Signal Processing Transforms ("SPTs") are formed for each sample, as part of a matrix of entry values. The matrix is decomposed into contiguous, non-overlapping two-dimensional cells of entries, and neural net analysis is applied to estimate reference sets of weight coefficients that provide sums with optimal matches to reference sets of values. The reference sets of weight coefficients are used to determine a correspondence between a new (unknown) word/phrase and a word/phrase in the database.

  6. ``Hiss, clicks and pops'' - The enigmatic sounds of meteors

    NASA Astrophysics Data System (ADS)

    Finnegan, J. A.

    2015-04-01

    The improbability of sounds heard simultaneously with meteors allows the phenomenon to remain on the margins of scientific interest and research. This is unjustified, since these audibly perceived electric field effects indicate complex, inconsistent and still unresolved electric-magnetic coupling and charge dynamics; interacting between the meteor; the ionosphere and mesosphere; stratosphere; troposphere and the surface of the earth. This paper reviews meteor acoustic effects, presents illustrating reports and hypotheses and includes a summary of similar and additional phenomena observed during the 2013 February 15 asteroid fragment disintegration above the Russian district of Chelyabinsk. An augmenting theory involving near ground, non uniform electric field production of Ozone, as a stimulated geo-physical phenomenon to explain some hissing `meteor sounds' is suggested in section 2.2. Unlike previous theories, electric-magnetic field fluctuation rates are not required to occur in the audio frequency range for this process to acoustically emit hissing and intermittent impulsive sounds; removing the requirements of direct conversion, passive human transduction or excited, localised acoustic `emitters'. Links to the Armagh Observatory All-sky meteor cameras, electrophonic meteor research and full construction plans for an extremely low frequency (ELF) receiver are also included.

  7. A Precision, Low-Cost GPS-Based Transmitter Synchronization Scheme for Improved AM Reception

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Stephen Fulton; Moore, Anthony

    2009-01-01

    This paper describes a highly accurate carrier-frequency synchronization scheme for actively, automatically locking multiple, remotely located AM broadcast transmitters to a common frequency/timing reference source such as GPS. The extremely tight frequency lock (to {approx}1 part in 10{sup 9} or better) permits the effective elimination of audible and even sub-audible beats between the local (desired) station's carrier signal and the distant stations carriers, usually received via skywave propagation during the evening and nighttime hours. These carrier-beat components cause annoying modulations of the desired station's audio at the receiver and concurrent distortion of the audio modulation from the distant station(s) andmore » often cause listeners to ldquotune outrdquo due to the low reception quality. Significant reduction or elimination of the beats and related effects will greatly enlarge the effective (interference-limited) listening area of the desired station (from 4 to 10 times as indicated in our tests) and simultaneously reduce the corresponding interference of the local transmitter to the distant stations as well. In addition, AM stereo (CQUAM) reception will be particularly improved by minimizing the phase shifts induced by co-channel interfering signals; hybrid digital (HD) signals will also benefit via reduction in beats from analog signals. The automatic frequency-control hardware described is inexpensive ($1000-$2000), requires no periodic recalibration, has essentially zero long-term drift, and could employ alternate wide-area frequency references of suitable accuracy, including broadcasts from WWVB, LORAN-C, and equivalent sources. The basic configuration of the GPS-disciplined oscillator which solves this problem is extremely simple. The main oscillator is a conventional high-stability quartz-crystal type. To counter long- term drifts, the oscillator is slightly adjusted to track a high-precision source of standard frequency obtained from a specialized GPS receiver (or other source), usually at 10.000 MHz. This very stable local reference frequency is then used as a clock for a standard digitally implemented frequency synthesizer, which is programmed to generate the specific carrier frequency desired. The stability of the disciplining source, typically {approx}1 part in 10{sup 9} to 10{sup 11}, is thus transferred to the final AM transmitter carrier output frequency.« less

  8. Tactical Sensors for Dispersed TNF (Tactical Nuclear Force) Units. Appendix 1.Tactical Sensory Survey.

    DTIC Science & Technology

    1983-06-30

    activating a separate transmitter, audible alarm, or contact closure. This sensor is compatible with any device that utilizes an input pulse or...transmitter, audible alarm, or contact closure. This sensor is compatible *i with any device that utilizes an output to produce an alarm. 110-4769-002. This...used to generate an alarm by activating a separate transmitter, audible alarm, or contact closure. This sensor is compatible with any device that

  9. A study of methods to predict and measure the transmission of sound through the walls of light aircraft. A survey of techniques for visualization of noise fields

    NASA Technical Reports Server (NTRS)

    Marshall, S. E.; Bernhard, R.

    1984-01-01

    A survey of the most widely used methods for visualizing acoustic phenomena is presented. Emphasis is placed on acoustic processes in the audible frequencies. Many visual problems are analyzed on computer graphic systems. A brief description of the current technology in computer graphics is included. The visualization technique survey will serve as basis for recommending an optimum scheme for displaying acoustic fields on computer graphic systems.

  10. Temporal Envelope Changes of Compression and Speech Rate: Combined Effects on Recognition for Older Adults

    ERIC Educational Resources Information Center

    Jenstad, Lorienne M.; Souza, Pamela E.

    2007-01-01

    Purpose: When understanding speech in complex listening situations, older adults with hearing loss face the double challenge of cochlear hearing loss and deficits of the aging auditory system. Wide-dynamic range compression (WDRC) is used in hearing aids as remediation for the loss of audibility associated with hearing loss. WDRC processing has…

  11. Description of a 20 kilohertz power distribution system

    NASA Technical Reports Server (NTRS)

    Hansen, I. G.

    1986-01-01

    A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution links multiphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

  12. Description of a 20 Kilohertz power distribution system

    NASA Technical Reports Server (NTRS)

    Hansen, I. G.

    1986-01-01

    A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution link; mulitphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

  13. An Evidence-Based Systematic Review of Amplitude Compression in Hearing Aids for School-Age Children With Hearing Loss

    PubMed Central

    McCreery, Ryan W.; Venediktov, Rebecca A.; Coleman, Jaumeiko J.; Leech, Hillary M.

    2013-01-01

    Purpose Two clinical questions were developed: one addressing the comparison of linear amplification with compression limiting to linear amplification with peak clipping, and the second comparing wide dynamic range compression with linear amplification for outcomes of audibility, speech recognition, speech and language, and self- or parent report in children with hearing loss. Method Twenty-six databases were systematically searched for studies addressing a clinical question and meeting all inclusion criteria. Studies were evaluated for methodological quality, and effect sizes were reported or calculated when possible. Results The literature search resulted in the inclusion of 8 studies. All 8 studies included comparisons of wide dynamic range compression to linear amplification, and 2 of the 8 studies provided comparisons of compression limiting versus peak clipping. Conclusions Moderate evidence from the included studies demonstrated that audibility was improved and speech recognition was either maintained or improved with wide dynamic range compression as compared with linear amplification. No significant differences were observed between compression limiting and peak clipping on outcomes (i.e., speech recognition and self-/parent report) reported across the 2 studies. Preference ratings appear to be influenced by participant characteristics and environmental factors. Further research is needed before conclusions can confidently be drawn. PMID:22858616

  14. Integrating the acoustics of running speech into the pure tone audiogram: a step from audibility to intelligibility and disability.

    PubMed

    Corthals, Paul

    2008-01-01

    The aim of the present study is to construct a simple method for visualizing and quantifying the audibility of speech on the audiogram and to predict speech intelligibility. The proposed method involves a series of indices on the audiogram form reflecting the sound pressure level distribution of running speech. The indices that coincide with a patient's pure tone thresholds reflect speech audibility and give evidence of residual functional hearing capacity. Two validation studies were conducted among sensorineurally hearing-impaired participants (n = 56 and n = 37, respectively) to investigate the relation with speech recognition ability and hearing disability. The potential of the new audibility indices as predictors for speech reception thresholds is comparable to the predictive potential of the ANSI 1968 articulation index and the ANSI 1997 speech intelligibility index. The sum of indices or a weighted combination can explain considerable proportions of variance in speech reception results for sentences in quiet free field conditions. The proportions of variance that can be explained in questionnaire results on hearing disability are less, presumably because the threshold indices almost exclusively reflect message audibility and much less the psychosocial consequences of hearing deficits. The outcomes underpin the validity of the new audibility indexing system, even though the proposed method may be better suited for predicting relative performance across a set of conditions than for predicting absolute speech recognition performance. (c) 2007 S. Karger AG, Basel

  15. Design and implementation of an audio indicator

    NASA Astrophysics Data System (ADS)

    Zheng, Shiyong; Li, Zhao; Li, Biqing

    2017-04-01

    This page proposed an audio indicator which designed by using C9014, LED by operational amplifier level indicator, the decimal count/distributor of CD4017. The experimental can control audibly neon and holiday lights through the signal. Input audio signal after C9014 composed of operational amplifier for power amplifier, the adjust potentiometer extraction amplification signal input voltage CD4017 distributors make its drive to count, then connect the LED display running situation of the circuit. This simple audio indicator just use only U1 and can produce two colors LED with the audio signal tandem come pursuit of the running effect, from LED display the running of the situation takes can understand the general audio signal. The variation in the audio and the frequency of the signal and the corresponding level size. In this light can achieve jump to change, slowly, atlas, lighting four forms, used in home, hotel, discos, theater, advertising and other fields, and a wide range of USES, rU1h life in a modern society.

  16. The forced sound transmission of finite single leaf walls using a variational technique.

    PubMed

    Brunskog, Jonas

    2012-09-01

    The single wall is the simplest element of concern in building acoustics, but there still remain some open questions regarding the sound insulation of this simple case. The two main reasons for this are the effects on the excitation and sound radiation of the wall when it has a finite size, and the fact that the wave field in the wall is consisting of two types of waves, namely forced waves due to the exciting acoustic field, and free bending waves due to reflections in the boundary. The aim of the present paper is to derive simple analytical formulas for the forced part of the airborne sound insulation of a single homogeneous wall of finite size, using a variational technique based on the integral-differential equation of the fluid loaded wall. The so derived formulas are valid in the entire audible frequency range. The results are compared with full numerical calculations, measurements and alternative theory, with reasonable agreement.

  17. Effectiveness of Audible Warning Devices on Emergency Vehicles.

    DOT National Transportation Integrated Search

    1977-08-01

    The purpose of the study was to examine the effectiveness of audible warning devices (AWD's) on emergency vehicles in terms of aural detectability. Community noise intrusion and opportunities for AWD optimization were also investigated. Measurements ...

  18. The relationship between professional operatic soprano voice and high range spectral energy

    NASA Astrophysics Data System (ADS)

    Barnes, Jennifer J.; Davis, Pamela; Oates, Jennifer; Chapman, Janice

    2004-07-01

    Operatic sopranos need to be audible over an orchestra yet they are not considered to possess a singer's formant. As in other voice types, some singers are more successful than others at being heard and so this work investigated the frequency range of the singer's formant between 2000 and 4000 Hz to consider the question of extra energy in this range. Such energy would give an advantage over an orchestra, so the aims were to ascertain what levels of excess energy there might be and look at any relationship between extra energy levels and performance level. The voices of six operatic sopranos (national and international standard) were recorded performing vowel and song tasks and subsequently analyzed acoustically. Measures taken from vowel data were compared with song task data to assess the consistency of the approaches. Comparisons were also made with regard to two conditions of intended projection (maximal and comfortable), two song tasks (anthem and aria), two recording environments (studio and anechoic room), and between subjects. Ranking the singers from highest energy result to lowest showed the consistency of the results from both vowel and song methods and correlated reasonably well with the performance level of the subjects. The use of formant tuning is considered and examined.

  19. Vibrational Profiling of Brain Tumors and Cells

    PubMed Central

    Nelson, Sultan L; Proctor, Dustin T; Ghasemloonia, Ahmad; Lama, Sanju; Zareinia, Kourosh; Ahn, Younghee; Al-Saiedy, Mustafa R; Green, Francis HY; Amrein, Matthias W; Sutherland, Garnette R

    2017-01-01

    This study reports vibration profiles of neuronal cells and tissues as well as brain tumor and neocortical specimens. A contact-free method and analysis protocol was designed to convert an atomic force microscope into an ultra-sensitive microphone with capacity to record and listen to live biological samples. A frequency of 3.4 Hz was observed for both cultured rat hippocampal neurons and tissues and vibration could be modulated pharmacologically. Malignant astrocytoma tissue samples obtained from operating room, transported in artificial cerebrospinal fluid, and tested within an hour, vibrated with a much different frequency profile and amplitude, compared to meningioma or lateral temporal cortex providing a quantifiable measurement to accurately distinguish the three tissues in real-time. Vibration signals were converted to audible sound waves by frequency modulation, thus demonstrating, acoustic patterns unique to meningioma, malignant astrocytoma and neocortex. PMID:28744324

  20. Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces.

    PubMed

    Liu, Yuhao; Norton, James J S; Qazi, Raza; Zou, Zhanan; Ammann, Kaitlyn R; Liu, Hank; Yan, Lingqing; Tran, Phat L; Jang, Kyung-In; Lee, Jung Woo; Zhang, Douglas; Kilian, Kristopher A; Jung, Sung Hee; Bretl, Timothy; Xiao, Jianliang; Slepian, Marvin J; Huang, Yonggang; Jeong, Jae-Woong; Rogers, John A

    2016-11-01

    Physiological mechano-acoustic signals, often with frequencies and intensities that are beyond those associated with the audible range, provide information of great clinical utility. Stethoscopes and digital accelerometers in conventional packages can capture some relevant data, but neither is suitable for use in a continuous, wearable mode, and both have shortcomings associated with mechanical transduction of signals through the skin. We report a soft, conformal class of device configured specifically for mechano-acoustic recording from the skin, capable of being used on nearly any part of the body, in forms that maximize detectable signals and allow for multimodal operation, such as electrophysiological recording. Experimental and computational studies highlight the key roles of low effective modulus and low areal mass density for effective operation in this type of measurement mode on the skin. Demonstrations involving seismocardiography and heart murmur detection in a series of cardiac patients illustrate utility in advanced clinical diagnostics. Monitoring of pump thrombosis in ventricular assist devices provides an example in characterization of mechanical implants. Speech recognition and human-machine interfaces represent additional demonstrated applications. These and other possibilities suggest broad-ranging uses for soft, skin-integrated digital technologies that can capture human body acoustics.

  1. Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces

    PubMed Central

    Liu, Yuhao; Norton, James J. S.; Qazi, Raza; Zou, Zhanan; Ammann, Kaitlyn R.; Liu, Hank; Yan, Lingqing; Tran, Phat L.; Jang, Kyung-In; Lee, Jung Woo; Zhang, Douglas; Kilian, Kristopher A.; Jung, Sung Hee; Bretl, Timothy; Xiao, Jianliang; Slepian, Marvin J.; Huang, Yonggang; Jeong, Jae-Woong; Rogers, John A.

    2016-01-01

    Physiological mechano-acoustic signals, often with frequencies and intensities that are beyond those associated with the audible range, provide information of great clinical utility. Stethoscopes and digital accelerometers in conventional packages can capture some relevant data, but neither is suitable for use in a continuous, wearable mode, and both have shortcomings associated with mechanical transduction of signals through the skin. We report a soft, conformal class of device configured specifically for mechano-acoustic recording from the skin, capable of being used on nearly any part of the body, in forms that maximize detectable signals and allow for multimodal operation, such as electrophysiological recording. Experimental and computational studies highlight the key roles of low effective modulus and low areal mass density for effective operation in this type of measurement mode on the skin. Demonstrations involving seismocardiography and heart murmur detection in a series of cardiac patients illustrate utility in advanced clinical diagnostics. Monitoring of pump thrombosis in ventricular assist devices provides an example in characterization of mechanical implants. Speech recognition and human-machine interfaces represent additional demonstrated applications. These and other possibilities suggest broad-ranging uses for soft, skin-integrated digital technologies that can capture human body acoustics. PMID:28138529

  2. Audible sonar images generated with proprioception for target analysis.

    PubMed

    Kuc, Roman B

    2017-05-01

    Some blind humans have demonstrated the ability to detect and classify objects with echolocation using palatal clicks. An audible-sonar robot mimics human click emissions, binaural hearing, and head movements to extract interaural time and level differences from target echoes. Targets of various complexity are examined by transverse displacements of the sonar and by target pose rotations that model movements performed by the blind. Controlled sonar movements executed by the robot provide data that model proprioception information available to blind humans for examining targets from various aspects. The audible sonar uses this sonar location and orientation information to form two-dimensional target images that are similar to medical diagnostic ultrasound tomograms. Simple targets, such as single round and square posts, produce distinguishable and recognizable images. More complex targets configured with several simple objects generate diffraction effects and multiple reflections that produce image artifacts. The presentation illustrates the capabilities and limitations of target classification from audible sonar images.

  3. The importance of laughing in your face: influences of visual laughter on auditory laughter perception.

    PubMed

    Jordan, Timothy R; Abedipour, Lily

    2010-01-01

    Hearing the sound of laughter is important for social communication, but processes contributing to the audibility of laughter remain to be determined. Production of laughter resembles production of speech in that both involve visible facial movements accompanying socially significant auditory signals. However, while it is known that speech is more audible when the facial movements producing the speech sound can be seen, similar visual enhancement of the audibility of laughter remains unknown. To address this issue, spontaneously occurring laughter was edited to produce stimuli comprising visual laughter, auditory laughter, visual and auditory laughter combined, and no laughter at all (either visual or auditory), all presented in four levels of background noise. Visual laughter and no-laughter stimuli produced very few reports of auditory laughter. However, visual laughter consistently made auditory laughter more audible, compared to the same auditory signal presented without visual laughter, resembling findings reported previously for speech.

  4. Quantification of the effects of audible rattle and source type on the human response to environmental vibration.

    PubMed

    Woodcock, J; Sica, G; Peris, E; Sharp, C; Moorhouse, A T; Waddington, D C

    2016-03-01

    The present research quantifies the influence of source type and the presence of audible vibration-induced rattle on annoyance caused by vibration in residential environments. The sources of vibration considered are railway and the construction of a light rail system. Data were measured in the United Kingdom using a socio-vibration survey (N = 1281). These data are analyzed using ordinal logit models to produce exposure-response relationships describing community annoyance as a function of vibration exposure. The influence of source type and the presence of audible vibration-induced rattle on annoyance are investigated using dummy variable analysis, and quantified using odds-ratios and community tolerance levels. It is concluded that the sample population is more likely to express higher levels of annoyance if the vibration source is construction compared to railway, and if vibration-induced rattle is audible.

  5. The direct and inverse problems of an air-saturated porous cylinder submitted to acoustic radiation.

    PubMed

    Ogam, Erick; Depollier, Claude; Fellah, Z E A

    2010-09-01

    Gas-saturated porous skeleton materials such as geomaterials, polymeric and metallic foams, or biomaterials are fundamental in a diverse range of applications, from structural materials to energy technologies. Most polymeric foams are used for noise control applications and knowledge of the manner in which the energy of sound waves is dissipated with respect to the intrinsic acoustic properties is important for the design of sound packages. Foams are often employed in the audible, low frequency range where modeling and measurement techniques for the recovery of physical parameters responsible for energy loss are still few. Accurate acoustic methods of characterization of porous media are based on the measurement of the transmitted and/or reflected acoustic waves by platelike specimens at ultrasonic frequencies. In this study we develop an acoustic method for the recovery of the material parameters of a rigid-frame, air-saturated polymeric foam cylinder. A dispersion relation for sound wave propagation in the porous medium is derived from the propagation equations and a model solution is sought based on plane-wave decomposition using orthogonal cylindrical functions. The explicit analytical solution equation of the scattered field shows that it is also dependent on the intrinsic acoustic parameters of the porous cylinder, namely, porosity, tortuosity, and flow resistivity (permeability). The inverse problem of the recovery of the flow resistivity and porosity is solved by seeking the minima of the objective functions consisting of the sum of squared residuals of the differences between the experimental and theoretical scattered field data.

  6. The Relationship between Reduplicated Babble Onset and Laterality Biases in Infant Rhythmic Arm Movements

    ERIC Educational Resources Information Center

    Iverson, Jana M.; Hall, Amanda J.; Nickel, Lindsay; Wozniak, Robert H.

    2007-01-01

    This study examined changes in rhythmic arm shaking and laterality biases in infants observed longitudinally at three points: just prior to, at, and just following reduplicated babble onset. Infants (ranging in age from 4 to 9 months at babble onset) were videotaped at home as they played with two visually identical audible and silent rattles…

  7. Hair cells use active zones with different voltage dependence of Ca2+ influx to decompose sounds into complementary neural codes

    PubMed Central

    Ohn, Tzu-Lun; Rutherford, Mark A.; Jing, Zhizi; Jung, Sangyong; Duque-Afonso, Carlos J.; Hoch, Gerhard; Picher, Maria Magdalena; Scharinger, Anja; Strenzke, Nicola; Moser, Tobias

    2016-01-01

    For sounds of a given frequency, spiral ganglion neurons (SGNs) with different thresholds and dynamic ranges collectively encode the wide range of audible sound pressures. Heterogeneity of synapses between inner hair cells (IHCs) and SGNs is an attractive candidate mechanism for generating complementary neural codes covering the entire dynamic range. Here, we quantified active zone (AZ) properties as a function of AZ position within mouse IHCs by combining patch clamp and imaging of presynaptic Ca2+ influx and by immunohistochemistry. We report substantial AZ heterogeneity whereby the voltage of half-maximal activation of Ca2+ influx ranged over ∼20 mV. Ca2+ influx at AZs facing away from the ganglion activated at weaker depolarizations. Estimates of AZ size and Ca2+ channel number were correlated and larger when AZs faced the ganglion. Disruption of the deafness gene GIPC3 in mice shifted the activation of presynaptic Ca2+ influx to more hyperpolarized potentials and increased the spontaneous SGN discharge. Moreover, Gipc3 disruption enhanced Ca2+ influx and exocytosis in IHCs, reversed the spatial gradient of maximal Ca2+ influx in IHCs, and increased the maximal firing rate of SGNs at sound onset. We propose that IHCs diversify Ca2+ channel properties among AZs and thereby contribute to decomposing auditory information into complementary representations in SGNs. PMID:27462107

  8. Remote Infrared Audible Signage (RIAS) Pilot Program : evaluation report

    DOT National Transportation Integrated Search

    2009-09-01

    This report presents evaluation findings on the Remote Infrared Audible Signage (RIAS) Pilot Program in the Puget Sound Region of Washington. The installation, demonstration and evaluation of RIAS were required by a provision in the Safe, Accountable...

  9. Infrasonic Stethoscope for Monitoring Physiological Processes

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor); Dimarcantonio, Albert L. (Inventor)

    2018-01-01

    An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece.

  10. Infrasonic Stethoscope for Monitoring Physiological Processes

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor); Dimarcantonio, Albert L. (Inventor)

    2016-01-01

    An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece.

  11. The rodent ultrasound production mechanism.

    PubMed

    Roberts, L H

    1975-03-01

    Rodents produce two types of sounds, audible and ultrasonic, that differ markedly in physical structure. Studies of sound production in light gases show that whereas the audible cries appear to be produced, as in the case of most other mammals, by vibrating structures in the larynx, the ultrasonic cries are produced by a different mechanism, probably a whistle. 'Bird-call' whistles are shown to have all the properties of rodent ultrasonic cries and to mimic them in almost every detail. Thus it is concluded that rodents have two distinct sound production mechanisms, one for audible cries and one for ultrasonic cries.

  12. Self-Assessed Hearing Handicap in Older Adults With Poorer-Than-Predicted Speech Recognition in Noise.

    PubMed

    Eckert, Mark A; Matthews, Lois J; Dubno, Judy R

    2017-01-01

    Even older adults with relatively mild hearing loss report hearing handicap, suggesting that hearing handicap is not completely explained by reduced speech audibility. We examined the extent to which self-assessed ratings of hearing handicap using the Hearing Handicap Inventory for the Elderly (HHIE; Ventry & Weinstein, 1982) were significantly associated with measures of speech recognition in noise that controlled for differences in speech audibility. One hundred sixty-two middle-aged and older adults had HHIE total scores that were significantly associated with audibility-adjusted measures of speech recognition for low-context but not high-context sentences. These findings were driven by HHIE items involving negative feelings related to communication difficulties that also captured variance in subjective ratings of effort and frustration that predicted speech recognition. The average pure-tone threshold accounted for some of the variance in the association between the HHIE and audibility-adjusted speech recognition, suggesting an effect of central and peripheral auditory system decline related to elevated thresholds. The accumulation of difficult listening experiences appears to produce a self-assessment of hearing handicap resulting from (a) reduced audibility of stimuli, (b) declines in the central and peripheral auditory system function, and (c) additional individual variation in central nervous system function.

  13. Self-Assessed Hearing Handicap in Older Adults With Poorer-Than-Predicted Speech Recognition in Noise

    PubMed Central

    Matthews, Lois J.; Dubno, Judy R.

    2017-01-01

    Purpose Even older adults with relatively mild hearing loss report hearing handicap, suggesting that hearing handicap is not completely explained by reduced speech audibility. Method We examined the extent to which self-assessed ratings of hearing handicap using the Hearing Handicap Inventory for the Elderly (HHIE; Ventry & Weinstein, 1982) were significantly associated with measures of speech recognition in noise that controlled for differences in speech audibility. Results One hundred sixty-two middle-aged and older adults had HHIE total scores that were significantly associated with audibility-adjusted measures of speech recognition for low-context but not high-context sentences. These findings were driven by HHIE items involving negative feelings related to communication difficulties that also captured variance in subjective ratings of effort and frustration that predicted speech recognition. The average pure-tone threshold accounted for some of the variance in the association between the HHIE and audibility-adjusted speech recognition, suggesting an effect of central and peripheral auditory system decline related to elevated thresholds. Conclusion The accumulation of difficult listening experiences appears to produce a self-assessment of hearing handicap resulting from (a) reduced audibility of stimuli, (b) declines in the central and peripheral auditory system function, and (c) additional individual variation in central nervous system function. PMID:28060993

  14. Locating arbitrarily time-dependent sound sources in three dimensional space in real time.

    PubMed

    Wu, Sean F; Zhu, Na

    2010-08-01

    This paper presents a method for locating arbitrarily time-dependent acoustic sources in a free field in real time by using only four microphones. This method is capable of handling a wide variety of acoustic signals, including broadband, narrowband, impulsive, and continuous sound over the entire audible frequency range, produced by multiple sources in three dimensional (3D) space. Locations of acoustic sources are indicated by the Cartesian coordinates. The underlying principle of this method is a hybrid approach that consists of modeling of acoustic radiation from a point source in a free field, triangulation, and de-noising to enhance the signal to noise ratio (SNR). Numerical simulations are conducted to study the impacts of SNR, microphone spacing, source distance and frequency on spatial resolution and accuracy of source localizations. Based on these results, a simple device that consists of four microphones mounted on three mutually orthogonal axes at an optimal distance, a four-channel signal conditioner, and a camera is fabricated. Experiments are conducted in different environments to assess its effectiveness in locating sources that produce arbitrarily time-dependent acoustic signals, regardless whether a sound source is stationary or moves in space, even toward behind measurement microphones. Practical limitations on this method are discussed.

  15. An experimental investigation of thermoacoustic lasers operating in audible frequency range

    NASA Astrophysics Data System (ADS)

    Kolhe, Sanket Anil

    Thermoacoustic lasers convert heat from a high-temperature heat source into acoustic power while rejecting waste heat to a low temperature sink. The working fluids involved can be air or noble gases which are nontoxic and environmentally benign. Simple in construction due to absence of moving parts, thermoacoustic lasers can be employed to achieve generation of electricity at individual homes, water-heating for domestic purposes, and to facilitate space heating and cooling. The possibility of utilizing waste heat or solar energy to run thermoacoustic devices makes them technically promising and economically viable to generate large quantities of acoustic energy. The research presented in this thesis deals with the effects of geometric parameters (stack position, stack length, tube length) associated with a thermoacoustic laser on the output sound wave. The effects of varying input power on acoustic output were also studied. Based on the experiments, optimum operating conditions were identified and qualitative and/or quantitative explanations were provided to justify our observations. It was observed that the maximum sound pressure level was generated for the laser with the stack positioned at a distance of quarter lengths of a resonator from the closed end. Higher sound pressure levels were recorded for the laser with longer stack lengths and longer resonator lengths. Efforts were also made to develop high-frequency thermoacoustic lasers.

  16. Relative contributions of specific frequency bands to the loudness of broadband sounds.

    PubMed

    Jesteadt, Walt; Walker, Sara M; Ogun, Oluwaseye A; Ohlrich, Brenda; Brunette, Katyarina E; Wróblewski, Marcin; Schmid, Kendra K

    2017-09-01

    Listeners with normal hearing (NH) and sensorineural hearing loss (SNHL) were asked to compare pairs of noise stimuli and choose the louder noise in each pair. Each noise was made up of 15, two-ERB N (equivalent rectangular bandwidth) wide frequency bands that varied independently over a 12-dB range from one presentation to the next. Mean levels of the bands followed the long-term average speech spectrum (LTASS) or were set to 43, 51, or 59 dB sound pressure level (SPL). The relative contribution of each band to the total loudness of the noise was determined by computing the correlation between the difference in levels for a given band on every trial and the listener's decision on that trial. Weights for SNHL listeners were governed by audibility and the spectrum of the noise stimuli, with bands near the spectral peak of the LTASS noise receiving greatest weight. NH listeners assigned greater weight to the lowest and highest bands, an effect that increased with overall level, but did not assign greater weight to bands near the LTASS peak. Additional loudness-matching and paired-comparison studies using stimuli missing one of the 15 bands showed a significant contribution by the highest band, but properties other than loudness may have contributed to the decisions.

  17. Discovery of rapid whistlers close to Jupiter implying lightning rates similar to those on Earth

    NASA Astrophysics Data System (ADS)

    Kolmašová, Ivana; Imai, Masafumi; Santolík, Ondřej; Kurth, William S.; Hospodarsky, George B.; Gurnett, Donald A.; Connerney, John E. P.; Bolton, Scott J.

    2018-06-01

    Electrical currents in atmospheric lightning strokes generate impulsive radio waves in a broad range of frequencies, called atmospherics. These waves can be modified by their passage through the plasma environment of a planet into the form of dispersed whistlers1. In the Io plasma torus around Jupiter, Voyager 1 detected whistlers as several-seconds-long slowly falling tones at audible frequencies2. These measurements were the first evidence of lightning at Jupiter. Subsequently, Jovian lightning was observed by optical cameras on board several spacecraft in the form of localized flashes of light3-7. Here, we show measurements by the Waves instrument8 on board the Juno spacecraft9-11 that indicate observations of Jovian rapid whistlers: a form of dispersed atmospherics at extremely short timescales of several milliseconds to several tens of milliseconds. On the basis of these measurements, we report over 1,600 lightning detections, the largest set obtained to date. The data were acquired during close approaches to Jupiter between August 2016 and September 2017, at radial distances below 5 Jovian radii. We detected up to four lightning strokes per second, similar to rates in thunderstorms on Earth12 and six times the peak rates from the Voyager 1 observations13.

  18. Realization of an omnidirectional source of sound using parametric loudspeakers.

    PubMed

    Sayin, Umut; Artís, Pere; Guasch, Oriol

    2013-09-01

    Parametric loudspeakers are often used in beam forming applications where a high directivity is required. Withal, in this paper it is proposed to use such devices to build an omnidirectional source of sound. An initial prototype, the omnidirectional parametric loudspeaker (OPL), consisting of a sphere with hundreds of ultrasonic transducers placed on it has been constructed. The OPL emits audible sound thanks to the parametric acoustic array phenomenon, and the close proximity and the large number of transducers results in the generation of a highly omnidirectional sound field. Comparisons with conventional dodecahedron loudspeakers have been made in terms of directivity, frequency response, and in applications such as the generation of diffuse acoustic fields in reverberant chambers. The OPL prototype has performed better than the conventional loudspeaker especially for frequencies higher than 500 Hz, its main drawback being the difficulty to generate intense pressure levels at low frequencies.

  19. An audible automobile back-up pedestrian warning device--development and evaluation

    DOT National Transportation Integrated Search

    1976-11-01

    The purpose of the study was to develop and field-test an audible back-up warning device for use on automobiles. Detailed criteria of pedestrian age and hearing ability combined with noise characteristics of typical accident sites provide the basis f...

  20. Audibility threshold spectrum for prominent discrete tone analysis

    NASA Astrophysics Data System (ADS)

    Kimizuka, Ikuo

    2005-09-01

    To evaluate the annoyance of tonal components in noise emissions, ANSI S1.13 (for general purposes) and/or ISO 7779/ECMA-74 (dedicatedfor IT equipment) state two similar metrics: tone-to-noise ratio (TNR) and prominence ratio(PR). By these or either of these two parameters, noise of question with a sharp spectral peak is analyzed by high resolution FFF and classified as prominent when it exceeds some criterion curve. According to present procedures, however this designation is dependent on only the spectral shape. To resolve this problem, the author proposes a threshold spectrum of human ear audibility. The spectrum is based on the reference threshold of hearing which is defined in ISO 389-7 and/or ISO 226. With this spectrum, one can objectively define whether the noise peak of question is audible or not, by simple comparison of the peak amplitude of noise emission and the corresponding value of threshold. Applying the threshold, one can avoid overkilling or unnecessary action for noise. Such a peak with absolutely low amplitude is not audible.

  1. The effects of limited bandwidth and noise on verbal processing time and word recall in normal-hearing children.

    PubMed

    McCreery, Ryan W; Stelmachowicz, Patricia G

    2013-09-01

    Understanding speech in acoustically degraded environments can place significant cognitive demands on school-age children who are developing the cognitive and linguistic skills needed to support this process. Previous studies suggest the speech understanding, word learning, and academic performance can be negatively impacted by background noise, but the effect of limited audibility on cognitive processes in children has not been directly studied. The aim of the present study was to evaluate the impact of limited audibility on speech understanding and working memory tasks in school-age children with normal hearing. Seventeen children with normal hearing between 6 and 12 years of age participated in the present study. Repetition of nonword consonant-vowel-consonant stimuli was measured under conditions with combinations of two different signal to noise ratios (SNRs; 3 and 9 dB) and two low-pass filter settings (3.2 and 5.6 kHz). Verbal processing time was calculated based on the time from the onset of the stimulus to the onset of the child's response. Monosyllabic word repetition and recall were also measured in conditions with a full bandwidth and 5.6 kHz low-pass cutoff. Nonword repetition scores decreased as audibility decreased. Verbal processing time increased as audibility decreased, consistent with predictions based on increased listening effort. Although monosyllabic word repetition did not vary between the full bandwidth and 5.6 kHz low-pass filter condition, recall was significantly poorer in the condition with limited bandwidth (low pass at 5.6 kHz). Age and expressive language scores predicted performance on word recall tasks, but did not predict nonword repetition accuracy or verbal processing time. Decreased audibility was associated with reduced accuracy for nonword repetition and increased verbal processing time in children with normal hearing. Deficits in free recall were observed even under conditions where word repetition was not affected. The negative effects of reduced audibility may occur even under conditions where speech repetition is not impacted. Limited stimulus audibility may result in greater cognitive effort for verbal rehearsal in working memory and may limit the availability of cognitive resources to allocate to working memory and other processes.

  2. Contactless ultrasonic energy transfer for wireless systems: acoustic-piezoelectric structure interaction modeling and performance enhancement

    NASA Astrophysics Data System (ADS)

    Shahab, S.; Erturk, A.

    2014-12-01

    There are several applications of wireless electronic components with little or no ambient energy available to harvest, yet wireless battery charging for such systems is still of great interest. Example applications range from biomedical implants to sensors located in hazardous environments. Energy transfer based on the propagation of acoustic waves at ultrasonic frequencies is a recently explored alternative that offers increased transmitter-receiver distance, reduced loss and the elimination of electromagnetic fields. As this research area receives growing attention, there is an increased need for fully coupled model development to quantify the energy transfer characteristics, with a focus on the transmitter, receiver, medium, geometric and material parameters. We present multiphysics modeling and case studies of the contactless ultrasonic energy transfer for wireless electronic components submerged in fluid. The source is a pulsating sphere, and the receiver is a piezoelectric bar operating in the 33-mode of piezoelectricity with a fundamental resonance frequency above the audible frequency range. The goal is to quantify the electrical power delivered to the load (connected to the receiver) in terms of the source strength. Both the analytical and finite element models have been developed for the resulting acoustic-piezoelectric structure interaction problem. Resistive and resistive-inductive electrical loading cases are presented, and optimality conditions are discussed. Broadband power transfer is achieved by optimal resistive-reactive load tuning for performance enhancement and frequency-wise robustness. Significant enhancement of the power output is reported due to the use of a hard piezoelectric receiver (PZT-8) instead of a soft counterpart (PZT-5H) as a result of reduced material damping. The analytical multiphysics modeling approach given in this work can be used to predict and optimize the coupled system dynamics with very good accuracy and dramatically improved computational efficiency compared to the use of commercial finite element packages.

  3. Infrasonic Signals from the 29 June 2012 Derecho

    NASA Astrophysics Data System (ADS)

    Winslow, N.; Howard, W. B.; Pulli, J. J.; Kofford, A. S.

    2012-12-01

    Common weather events such as pressure fronts, tornados, and hurricanes generate infrasonic signals (sub-audible acoustic signals with an oscillatory frequency below 20 Hz). These signals can provide a distal (>10km) analysis of weather events because: (1) the attenuation of an infrasonic signal with distance is less than that of a similar audible signal, and (2) the propagation velocities of typical weather events are much slower than the speed of sound. The 29 June, 2012 Derecho (a widespread, long-lived, rapidly moving linear band of storms extending more than 240 miles and including wind gusts in excess of 58 mph) that stretched from Chicago, IL to Washington, DC generated infrasonic signals in addition to causing over $100 million in damage to the power systems of Virginia, West Virginia, and Maryland alone. The infrasonic (and seismic) signals from this event were recorded on the NCPA micro barometers along the northeastern edge of the current configuration of the USArray. These instruments, which sample at 40 Hz, exhibit a flat frequency response from around 0.1 Hz to above 20 Hz and show a sensitivity of 1.57 x 104 Volts/Pascal at 0.8 Hz. An analysis of the recordings observed at multiple stations identified several infrasonic signatures from the Derecho. The signal's duration was approximately 40 minutes and exhibited a large peak pressure fluctuation. A characteristic ramp up occurred before the peak pressure fluctuation, and the majority of the infrasonic energy occurred below 1 Hz. These signatures are analyzed within the context of the Derecho as an infrasonic source, and the propagation of infrasound in the atmosphere.

  4. Resting-Associated Vocalization Emitted by Captive Asian House Shrews (Suncus murinus): Acoustic Structure and Variability in an Unusual Mammalian Vocalization

    PubMed Central

    Schneiderová, Irena; Zouhar, Jan

    2014-01-01

    Shrews have rich vocal repertoires that include vocalizations within the human audible frequency range and ultrasonic vocalizations. Here, we recorded and analyzed in detail the acoustic structure of a vocalization with unclear functional significance that was spontaneously produced by 15 adult, captive Asian house shrews (Suncus murinus) while they were lying motionless and resting in their nests. This vocalization was usually emitted repeatedly in a long series with regular intervals. It showed some structural variability; however, the shrews most frequently emitted a tonal, low-frequency vocalization with minimal frequency modulation and a low, non-vocal click that was clearly noticeable at its beginning. There was no effect of sex, but the acoustic structure of the analyzed vocalizations differed significantly between individual shrews. The encoded individuality was low, but it cannot be excluded that this individuality would allow discrimination of family members, i.e., a male and female with their young, collectively resting in a common nest. The question remains whether the Asian house shrews indeed perceive the presence of their mates, parents or young resting in a common nest via the resting-associated vocalization and whether they use it to discriminate among their family members. Additional studies are needed to explain the possible functional significance of resting-associated vocalizations emitted by captive Asian house shrews. Our study highlights that the acoustic communication of shrews is a relatively understudied topic, particularly considering that they are highly vocal mammals. PMID:25390304

  5. 46 CFR 154.804 - Vacuum protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Vent.... (2) There must be a pressure switch that operates an audible and visual alarm in the cargo control station identifying the tank and the alarm condition and a remote group audible and visual alarm in the...

  6. 46 CFR 154.804 - Vacuum protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Vent.... (2) There must be a pressure switch that operates an audible and visual alarm in the cargo control station identifying the tank and the alarm condition and a remote group audible and visual alarm in the...

  7. 46 CFR 154.804 - Vacuum protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Vent.... (2) There must be a pressure switch that operates an audible and visual alarm in the cargo control station identifying the tank and the alarm condition and a remote group audible and visual alarm in the...

  8. Experimental and analytical studies of a true airspeed sensor

    NASA Technical Reports Server (NTRS)

    Goglia, G. L.; Shen, J. Y.

    1983-01-01

    A true airspeed sensor based on the precession of a vortex whistle for sensing airspeeds up to 321.9 km/hr (200 mph). In an attempt to model the complicated fluid mechanics of the vortex precession, three dimensional, inviscid, unsteady, incompressible fluid flow was studied by using the hydrodynamical linearized stability theory. The temporal stability approach was used to derive the relationship between the true airspeed and frequency response. The results show that the frequency response is linearly proportional to the airspeed. A computer program was developed to obtain the numerical solution. Computational results for various parameters were obtained. The designed sensor basically consisted of a vortex tube, a swirler, and a transducer system. A microphone converted the audible tone to an electronic frequency signal. Measurements for both the closed conduit tests and wind tunnel tests were recorded. For a specific flow rate or airspeed, larger exit swirler angles produced higher frequencies. For a smaller cross sectional area in the precessional flow region, the frequency was higher. It was observed that as the airspeed was increased the Strouhal number remained constant.

  9. Two-Band Pyrometers Detect Hydrogen Fires

    NASA Technical Reports Server (NTRS)

    Collins, J. David; Youngquist, Robert C.; Simmons, Stephen M.

    1993-01-01

    Two-band infrared pyrometers detect small hydrogen fires at greater distances in full daylight being developed. Detectors utilize part of infrared spectrum in which signals from hydrogen flames 10 to the 3rd power to 10 to the 4th power times as intense as ultraviolet region of current detectors. Utilize low-loss infrared lenses for focusing and for limiting fields of view to screen out spurious signals from nearby sources. Working distances of as much as 100 meters possible. Portable, battery-powered unit gives audible alarm, in form of increase in frequency of tone, when aimed at hydrogen fire.

  10. Seasonal presence of cetaceans and ambient noise levels in polar waters of the North Atlantic.

    PubMed

    Klinck, Holger; Nieukirk, Sharon L; Mellinger, David K; Klinck, Karolin; Matsumoto, Haruyoshi; Dziak, Robert P

    2012-09-01

    In 2009 two calibrated acoustic recorders were deployed in polar waters of the North Atlantic to study the seasonal occurrence of blue, fin, and sperm whales and to assess current ambient noise levels. Sounds from these cetaceans were recorded at both locations in most months of the year. During the summer months, seismic airguns associated with oil and gas exploration were audible for weeks at a time and dominated low frequency noise levels. Noise levels might further increase in the future as the receding sea ice enables extended human use of the area.

  11. Low-Frequency Cortical Oscillations Entrain to Subthreshold Rhythmic Auditory Stimuli

    PubMed Central

    Schroeder, Charles E.; Poeppel, David; van Atteveldt, Nienke

    2017-01-01

    Many environmental stimuli contain temporal regularities, a feature that can help predict forthcoming input. Phase locking (entrainment) of ongoing low-frequency neuronal oscillations to rhythmic stimuli is proposed as a potential mechanism for enhancing neuronal responses and perceptual sensitivity, by aligning high-excitability phases to events within a stimulus stream. Previous experiments show that rhythmic structure has a behavioral benefit even when the rhythm itself is below perceptual detection thresholds (ten Oever et al., 2014). It is not known whether this “inaudible” rhythmic sound stream also induces entrainment. Here we tested this hypothesis using magnetoencephalography and electrocorticography in humans to record changes in neuronal activity as subthreshold rhythmic stimuli gradually became audible. We found that significant phase locking to the rhythmic sounds preceded participants' detection of them. Moreover, no significant auditory-evoked responses accompanied this prethreshold entrainment. These auditory-evoked responses, distinguished by robust, broad-band increases in intertrial coherence, only appeared after sounds were reported as audible. Taken together with the reduced perceptual thresholds observed for rhythmic sequences, these findings support the proposition that entrainment of low-frequency oscillations serves a mechanistic role in enhancing perceptual sensitivity for temporally predictive sounds. This framework has broad implications for understanding the neural mechanisms involved in generating temporal predictions and their relevance for perception, attention, and awareness. SIGNIFICANCE STATEMENT The environment is full of rhythmically structured signals that the nervous system can exploit for information processing. Thus, it is important to understand how the brain processes such temporally structured, regular features of external stimuli. Here we report the alignment of slowly fluctuating oscillatory brain activity to external rhythmic structure before its behavioral detection. These results indicate that phase alignment is a general mechanism of the brain to process rhythmic structure and can occur without the perceptual detection of this temporal structure. PMID:28411273

  12. Mechanically Robust Magnetic Carbon Nanotube Papers Prepared with CoFe2O4 Nanoparticles for Electromagnetic Interference Shielding and Magnetomechanical Actuation.

    PubMed

    Lim, Guh-Hwan; Woo, Seongwon; Lee, Hoyoung; Moon, Kyoung-Seok; Sohn, Hiesang; Lee, Sang-Eui; Lim, Byungkwon

    2017-11-22

    The introduction of inorganic nanoparticles into carbon nanotube (CNT) papers can provide a versatile route to the fabrication of CNT papers with diverse functionalities, but it may lead to a reduction in their mechanical properties. Here, we describe a simple and effective strategy for the fabrication of mechanically robust magnetic CNT papers for electromagnetic interference (EMI) shielding and magnetomechanical actuation applications. The magnetic CNT papers were produced by vacuum filtration of an aqueous suspension of CNTs, CoFe 2 O 4 nanoparticles, and poly(vinyl alcohol) (PVA). PVA plays a critical role in enhancing the mechanical strength of CNT papers. The magnetic CNT papers containing 73 wt % of CoFe 2 O 4 nanoparticles exhibited high mechanical properties with Young's modulus of 3.2 GPa and tensile strength of 30.0 MPa. This magnetic CNT paper was successfully demonstrated as EMI shielding paper with shielding effectiveness of ∼30 dB (99.9%) in 0.5-1.0 GHz, and also as a magnetomechanical actuator in an audible frequency range from 200 to 20 000 Hz.

  13. Global patterns of changes in underwater sound transmission caused by ocean acidification

    NASA Astrophysics Data System (ADS)

    Ilyina, T.; Zeebe, R. E.; Brewer, P. G.

    2009-04-01

    Oceanic uptake of man-made CO2 leads to a decrease in the ocean pH and carbonate saturation state. This processes, known as ocean acidification is expected to have adverse effects on a variety of marine organisms. A surprising consequence of ocean acidification, which has gone widely unrecognized, is its effect on underwater sound transmission. Low-frequency sound absorption in the ocean occurs due to chemical relaxation of the pH-dependent boric acid-borate ion reaction. As ocean pH drops, sound absorption in the audible range decreases. The decreased sound absorption will amplify ambient noise levels, and enhance long distance sound transmission, although its exact environmental impact is uncertain. Changes in the underwater sound absorption will affect the operation of scientific, commercial, and naval applications that are based on ocean acoustics, with yet unknown consequences for marine life. We project these changes using a global biogeochemical model (HAMOCC), which is forced by the anthropogenic CO2 emissions during the years 1800-2300. Based on model projections, we quantify when and where in the ocean these ocean chemistry induced perturbations in sound absorption will occur.

  14. The Pulsar Quartet: Listening to a Galactic Symphony

    NASA Astrophysics Data System (ADS)

    Kiziltan, Bülent

    2014-06-01

    Pulsars are exotic dead stars that emit very regular radio pulses. These pulses are attributed to their regular rotation. Some pulsars are spinning fast enough that the audio equivalent waveform of their pulses fall within our hearing range. If human ears were tuned to radio waves it would have been possible to ‘hear’ these very compact stars. We produced the audio waveform of these pulsar signals and mapped them onto a frequency chart to find the corresponding musical notes. We use these ‘audible' pulsars like musical instruments in a symphony orchestra to play a full quartet. At the same time, an accompanying visual interface shows the realistic distribution of all pulsars in our own Galaxy. Pulsars shine as they play each note in the quartet with realistic brightening and subsequent dimming proportional to their rotational energies. This can serve as an educational tool at all levels to demonstrate many interesting aspects of stellar evolution and articulate an aesthetic connection of us with the cosmos. Interested in watching the light show while the Milky Way Pulsar Orchestra plays a quartet?

  15. 49 CFR 214.511 - Required audible warning devices for new on-track roadway maintenance machines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... roadway maintenance machines. 214.511 Section 214.511 Transportation Other Regulations Relating to... SAFETY On-Track Roadway Maintenance Machines and Hi-Rail Vehicles § 214.511 Required audible warning devices for new on-track roadway maintenance machines. Each new on-track roadway maintenance machine shall...

  16. 49 CFR 214.511 - Required audible warning devices for new on-track roadway maintenance machines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... roadway maintenance machines. 214.511 Section 214.511 Transportation Other Regulations Relating to... SAFETY On-Track Roadway Maintenance Machines and Hi-Rail Vehicles § 214.511 Required audible warning devices for new on-track roadway maintenance machines. Each new on-track roadway maintenance machine shall...

  17. Audible Conversational Affordances and Constraints of Verbalizing Professional Noticing during Prospective Teacher Lesson Study

    ERIC Educational Resources Information Center

    Amador, Julie M.; Carter, Ingrid S.

    2018-01-01

    Lesson Study, which assumes multiple variations, is a collaborative method that provides an opportunity for teachers to notice professionally. We analyzed how audible conversational components afforded and constrained the verbalization of professional noticing of a lesson study team. The team, comprised of six prospective teachers, a classroom…

  18. A microacoustic analysis including viscosity and thermal conductivity to model the effect of the protective cap on the acoustic response of a MEMS microphone

    PubMed Central

    Homentcovschi, D.; Miles, R. N.; Loeppert, P. V.; Zuckerwar, A. J.

    2013-01-01

    An analysis is presented of the effect of the protective cover on the acoustic response of a miniature silicon microphone. The microphone diaphragm is contained within a small rectangular enclosure and the sound enters through a small hole in the enclosure's top surface. A numerical model is presented to predict the variation in the sound field with position within the enclosure. An objective of this study is to determine up to which frequency the pressure distribution remains sufficiently uniform so that a pressure calibration can be made in free space. The secondary motivation for this effort is to facilitate microphone design by providing a means of predicting how the placement of the microphone diaphragm in the package affects the sensitivity and frequency response. While the size of the package is typically small relative to the wavelength of the sounds of interest, because the dimensions of the package are on the order of the thickness of the viscous boundary layer, viscosity can significantly affect the distribution of sound pressure around the diaphragm. In addition to the need to consider viscous effects, it is shown here that one must also carefully account for thermal conductivity to properly represent energy dissipation at the system's primary acoustic resonance frequency. The sound field is calculated using a solution of the linearized system consisting of continuity equation, Navier-Stokes equations, the state equation and the energy equation using a finite element approach. The predicted spatial variation of both the amplitude and phase of the sound pressure is shown over the range of audible frequencies. Excellent agreement is shown between the predicted and measured effects of the package on the microphone's sensitivity. PMID:24701031

  19. Decision strategies of hearing-impaired listeners in spectral shape discrimination

    NASA Astrophysics Data System (ADS)

    Lentz, Jennifer J.; Leek, Marjorie R.

    2002-03-01

    The ability to discriminate between sounds with different spectral shapes was evaluated for normal-hearing and hearing-impaired listeners. Listeners detected a 920-Hz tone added in phase to a single component of a standard consisting of the sum of five tones spaced equally on a logarithmic frequency scale ranging from 200 to 4200 Hz. An overall level randomization of 10 dB was either present or absent. In one subset of conditions, the no-perturbation conditions, the standard stimulus was the sum of equal-amplitude tones. In the perturbation conditions, the amplitudes of the components within a stimulus were randomly altered on every presentation. For both perturbation and no-perturbation conditions, thresholds for the detection of the 920-Hz tone were measured to compare sensitivity to changes in spectral shape between normal-hearing and hearing-impaired listeners. To assess whether hearing-impaired listeners relied on different regions of the spectrum to discriminate between sounds, spectral weights were estimated from the perturbed standards by correlating the listener's responses with the level differences per component across two intervals of a two-alternative forced-choice task. Results showed that hearing-impaired and normal-hearing listeners had similar sensitivity to changes in spectral shape. On average, across-frequency correlation functions also were similar for both groups of listeners, suggesting that as long as all components are audible and well separated in frequency, hearing-impaired listeners can use information across frequency as well as normal-hearing listeners. Analysis of the individual data revealed, however, that normal-hearing listeners may be better able to adopt optimal weighting schemes. This conclusion is only tentative, as differences in internal noise may need to be considered to interpret the results obtained from weighting studies between normal-hearing and hearing-impaired listeners.

  20. A numerical model to reproduce squeaking of ceramic-on-ceramic total hip arthroplasty. Influence of design and material.

    PubMed

    Piriou, P; Ouenzerfi, G; Migaud, H; Renault, E; Massi, F; Serrault, M

    2016-06-01

    Modern ceramic (CoC) bearings for hip arthroplasty (THA) have been used in younger patients who expect improved survivorship. However, audible squeaking produced by the implant is an annoying complication. Previous numerical simulations were not able to accurately reproduce in vitro and in vivo observations. Therefore, we developed a finite element model to: (1) reproduce in vitro squeaking and validate the model by comparing it with in vivo recordings, (2) determine why there are differences between in vivo and in vitro squeaking frequencies, (3) identify the stem's role in this squeaking, (4) predict which designs and materials are more likely to produce squeaking. A CoC THA numerical model can be developed that reproduces the squeaking frequencies observed in vivo. Numerical methods (finite element analysis [ANSYS]) and experimental methods (using a non-lubricated simulated hip with a cementless 32mm CoC THA) were developed to reproduce squeaking. Numerical analysis was performed to identify the frequencies that cause vibrations perceived as an acoustic emission. The finite element analysis (FEA) model was enhanced by adjusting periprosthetic bone and soft tissue elements in order to reproduce the squeaking frequencies recorded in vivo. A numerical method (complex eigenvalue analysis) was used to find the acoustic frequencies of the squeaking noise. The frequencies obtained from the model and the hip simulator were compared to those recorded in vivo. The numerical results were validated by experiments with the laboratory hip simulator. The frequencies obtained (mean 2790Hz with FEA, 2755Hz with simulator, decreasing to 1759Hz when bone and soft tissue were included in the FEA) were consistent with those of squeaking hips recorded in vivo (1521Hz). The cup and ceramic insert were the source of the vibration, but had little influence on the diffusion of the noise required to make the squeaking audible to the human ear. The FEA showed that diffusion of squeaking was due to an unstable vibration of the stem during frictional contact. The FEA predicted a higher rate of squeaking (at a lower coefficient of friction) when TZMF™ alloy is used instead of Ti6Al4V and when an anatomic press-fit stem is used instead of straight self-locking designs. The current FEA model is reliable; it can be used to assess various stem designs and alloys to predict the different rates of squeaking that certain stems will likely produce. Level IV in vitro study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Coupling of Head and Body Movement with Motion of the Audible Environment

    ERIC Educational Resources Information Center

    Stoffregen, Thomas A.; Villard, Sebastien; Kim, ChungGon; Ito, Kiyohide; Bardy, Benoit G.

    2009-01-01

    The authors asked whether standing posture could be controlled relative to audible oscillation of the environment. Blindfolded sighted adults were exposed to acoustic flow in a moving room, and were asked to move so as to maintain a constant distance between their head and the room. Acoustic flow had direct (source) and indirect (reflected)…

  2. Use of Audible and Chart-recorded Ultrasonography to Monitor Fetal Heart Rate and Uterine Blood Flow Parameters in Cattle

    USDA-ARS?s Scientific Manuscript database

    The objective of the present study was to evaluate the use of audible chart-recorded doppler ultrasonography (DUS) to monitor both uterine blood flow and fetal heart rate (FHR) during pregnancy in dairy cattle. Possible applications of DUS include the monitoring of fetal distress when a pregnancy be...

  3. The Use of Audible Traffic Signals in the United States.

    ERIC Educational Resources Information Center

    Peck, A. F.; Uslan, M.

    1990-01-01

    This paper discusses audible traffic signals (ATS) and their use by visually impaired pedestrians in the United States and other countries. Areas of concern are noted, including the types of intersections at which ATS should be installed, the locations of poles and buttons for activating the system, and the specific type of device used.…

  4. Impact of low-frequency sound on historic structures

    NASA Astrophysics Data System (ADS)

    Sutherland, Louis C.; Horonjeff, Richard D.

    2005-09-01

    In common usage, the term soundscape usually refers to portions of the sound spectrum audible to human observers, and perhaps more broadly other members of the animal kingdom. There is, however, a soundscape regime at the low end of the frequency spectrum (e.g., 10-25 Hz), which is inaudible to humans, where nonindigenous sound energy may cause noise-induced vibrations in structures. Such low frequency components may be of sufficient magnitude to pose damage risk potential to historic structures and cultural resources. Examples include Anasazi cliff and cave dwellings, and pueblo structures of vega type roof construction. Both are susceptible to noise induced vibration from low-frequency sound pressures that excite resonant frequencies in these structures. The initial damage mechanism is usually fatigue cracking. Many mechanisms are subtle, temporally multiphased, and not initially evident to the naked eye. This paper reviews the types of sources posing the greatest potential threat, their low-frequency spectral characteristics, typical structural responses, and the damage risk mechanisms involved. Measured sound and vibration levels, case history studies, and conditions favorable to damage risk are presented. The paper concludes with recommendations for increasing the damage risk knowledge base to better protect these resources.

  5. Analytical model for viscous damping and the spring force for perforated planar microstructures acting at both audible and ultrasonic frequencies

    PubMed Central

    Homentcovschi, Dorel; Miles, Ronald N.

    2008-01-01

    The paper presents a model for the squeezed film damping, the resistance of the holes, and the corresponding spring forces for a periodic perforated microstructure including the effects of compressibility, inertia, and rarefied gas. The viscous damping and spring forces are obtained by using the continuity equation. The analytical formula for the squeezed film damping is applied to analyze the response of an ultrasonic transducer. The inclusion of these effects in a model significantly improves the agreement with measured results. Finally, it is shown that the frequency dependence of the total damping and total spring force for a cell are very similar to those corresponding to a rectangular open microstructure without holes. A separate analysis reveals the importance of each particular correction. The most important is the compressibility correction; the inertia has to be considered only for determining the spring force and the damping force for sufficiently high frequencies. PMID:18646964

  6. Reverse transduction measured in the living cochlea by low-coherence heterodyne interferometry.

    PubMed

    Ren, Tianying; He, Wenxuan; Barr-Gillespie, Peter G

    2016-01-06

    It is generally believed that the remarkable sensitivity and frequency selectivity of mammalian hearing depend on outer hair cell-generated force, which amplifies sound-induced vibrations inside the cochlea. This 'reverse transduction' force production has never been demonstrated experimentally, however, in the living ear. Here by directly measuring microstructure vibrations inside the cochlear partition using a custom-built interferometer, we demonstrate that electrical stimulation can evoke both fast broadband and slow sharply tuned responses of the reticular lamina, but only a slow tuned response of the basilar membrane. Our results indicate that outer hair cells can generate sufficient force to drive the reticular lamina over all audible frequencies in living cochleae. Contrary to expectations, the cellular force causes a travelling wave rather than an immediate local vibration of the basilar membrane; this travelling wave vibrates in phase with the reticular lamina at the best frequency, and results in maximal vibration at the apical ends of outer hair cells.

  7. Insertion Loss of Personal Protective Clothing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shull D.J.; Biesel, V.B.; Cunefare, K.A.

    1999-05-13

    'The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested atmore » least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing''s noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'« less

  8. Audible Image Description as an Accommodation in Statewide Assessments for Students with Visual and Print Disabilities

    ERIC Educational Resources Information Center

    Ferrell, Kay Alicyn; Correa-Torres, Silvia M.; Howell, Jennifer Johnson; Pearson, Robert; Carver, Wendy Morrow; Groll, Amy Spencer; Anthony, Tanni L.; Matthews, Deborah; Gould, Bryan; O'Connell, Trisha; Botsford, Kathryn D,; Dewald, Hong Phangia; Smyth, Catherine A.; Dewald, Aaron John

    2017-01-01

    Introduction:Although image description has been identified as an accommodation for presentations conducted in the classroom, only a few U.S. states have approved it for use in high-stakes assessments. This study examined the use of audible image description as an assessment accommodation for students with visual and print disabilities by…

  9. Validity and Reliability of Visual Analog Scaling for Assessment of Hypernasality and Audible Nasal Emission in Children With Repaired Cleft Palate.

    PubMed

    Baylis, Adriane; Chapman, Kathy; Whitehill, Tara L; Group, The Americleft Speech

    2015-11-01

    To investigate the validity and reliability of multiple listener judgments of hypernasality and audible nasal emission, in children with repaired cleft palate, using visual analog scaling (VAS) and equal-appearing interval (EAI) scaling. Prospective comparative study of multiple listener ratings of hypernasality and audible nasal emission. Multisite institutional. Five trained and experienced speech-language pathologist listeners from the Americleft Speech Project. Average VAS and EAI ratings of hypernasality and audible nasal emission/turbulence for 12 video-recorded speech samples from the Americleft Speech Project. Intrarater and interrater reliability was computed, as well as linear and polynomial models of best fit. Intrarater and interrater reliability was acceptable for both rating methods; however, reliability was higher for VAS as compared to EAI ratings. When VAS ratings were plotted against EAI ratings, results revealed a stronger curvilinear relationship. The results of this study provide additional evidence that alternate rating methods such as VAS may offer improved validity and reliability over EAI ratings of speech. VAS should be considered a viable method for rating hypernasality and nasal emission in speech in children with repaired cleft palate.

  10. Guitar Strings as Standing Waves: A Demonstration

    NASA Astrophysics Data System (ADS)

    Davis, Michael

    2007-08-01

    An undergraduate student's first exposure to modern atomic theory tends to start with Bohr's model of the atom. This familiar introduction to atomic structure also marks a general chemistry student's first foray into waves. Many popular chemistry textbooks illustrate the concept of a standing wave in the development of the modern quantum model by using the phrase “as seen on a guitar string”. In these illustrations, the wave itself is often small and difficult to discern. The same phenomenon, however, can be easily and audibly observed. This demonstration uses an acoustic guitar to produce three unique harmonic vibrations, each of which is representative of a standing wave and illustrates the concept of quantization. Manipulation of the guitar string to produce a standing wave is pervasive in popular music and is audibly recognizable. Lightly placing a finger on the 12th, 7th, or 5th fret and strumming any one or all six strings can produce an audible example of a standing wave on a guitar. This corresponds to a standing wave with 1, 2, or 3 nodes, respectively. Attempting to induce a node at other points on a guitar string does not generate a standing wave, due to destructive interference, thus no audible tone is produced.

  11. Establishing the Response of Low Frequency Auditory Filters

    NASA Technical Reports Server (NTRS)

    Rafaelof, Menachem; Christian, Andrew; Shepherd, Kevin; Rizzi, Stephen; Stephenson, James

    2017-01-01

    The response of auditory filters is central to frequency selectivity of sound by the human auditory system. This is true especially for realistic complex sounds that are often encountered in many applications such as modeling the audibility of sound, voice recognition, noise cancelation, and the development of advanced hearing aid devices. The purpose of this study was to establish the response of low frequency (below 100Hz) auditory filters. Two experiments were designed and executed; the first was to measure subject's hearing threshold for pure tones (at 25, 31.5, 40, 50, 63 and 80 Hz), and the second was to measure the Psychophysical Tuning Curves (PTCs) at two signal frequencies (Fs= 40 and 63Hz). Experiment 1 involved 36 subjects while experiment 2 used 20 subjects selected from experiment 1. Both experiments were based on a 3-down 1-up 3AFC adaptive staircase test procedure using either a variable level narrow-band noise masker or a tone. A summary of the results includes masked threshold data in form of PTCs, the response of auditory filters, their distribution, and comparison with similar recently published data.

  12. A micromachined efficient parametric array loudspeaker with a wide radiation frequency band.

    PubMed

    Je, Yub; Lee, Haksue; Been, Kyounghun; Moon, Wonkyu

    2015-04-01

    Parametric array (PA) loudspeakers generate directional audible sound via the PA effect, which can make private listening possible. The practical applications of PA loudspeakers include information technology devices that require large power efficiency transducers with a wide frequency bandwidth. Piezoelectric micromachined ultrasonic transducers (PMUTs) are compact and efficient units for PA sources [Je, Lee, and Moon, Ultrasonics 53, 1124-1134 (2013)]. This study investigated the use of an array of PMUTs to make a PA loudspeaker with high power efficiency and wide bandwidth. The achievable maximum radiation bandwidth of the driver was calculated, and an array of PMUTs with two distinct resonance frequencies (f1 = 100 kHz, f2 = 110 kHz) was designed. Out-of-phase driving was used with the dual-resonance transducer array to increase the bandwidth. The fabricated PMUT array exhibited an efficiency of up to 71%, together with a ±3-dB bandwidth of 17 kHz for directly radiated primary waves, and 19.5 kHz (500 Hz to 20 kHz) for the difference frequency waves (with equalization).

  13. RADIATION COUNTER

    DOEpatents

    Goldsworthy, W.W.

    1958-02-01

    This patent relates to a radiation counter, and more particularly, to a scintillation counter having high uniform sensitivity over a wide area and capable of measuring alpha, beta, and gamma contamination over wide energy ranges, for use in quickly checking the contami-nation of personnel. Several photomultiplier tubes are disposed in parallel relationship with a light tight housing behind a wall of scintillation material. Mounted within the housing with the photomultipliers are circuit means for producing an audible sound for each pulse detected, and a range selector developing a voltage proportional to the repetition rate of the detected pulses and automatically altering its time constant when the voltage reaches a predetermined value, so that manual range adjustment of associated metering means is not required.

  14. Characterization of Underwater Sounds Produced by Trailing Suction Hopper Dredges During Sand Mining and Pump-out Operations

    DTIC Science & Technology

    2014-03-01

    origin and potential impacts on aquatic organisms including marine mammals (e.g., whales and seals), sea turtles , and fishes. Until recently these...species of whales and sea turtles , as well as many species of fish. Exposure to underwater sound may potentially affect communication, foraging...the audible range of several species of marine mammals such as whales and dolphins as well as sea turtles . Right (Eubalaena glacialis), humpback

  15. Nonlinear Frequency Compression in Hearing Aids: Impact on Speech and Language Development

    PubMed Central

    Bentler, Ruth; Walker, Elizabeth; McCreery, Ryan; Arenas, Richard M.; Roush, Patricia

    2015-01-01

    Objectives The research questions of this study were: (1) Are children using nonlinear frequency compression (NLFC) in their hearing aids getting better access to the speech signal than children using conventional processing schemes? The authors hypothesized that children whose hearing aids provided wider input bandwidth would have more access to the speech signal, as measured by an adaptation of the Speech Intelligibility Index, and (2) are speech and language skills different for children who have been fit with the two different technologies; if so, in what areas? The authors hypothesized that if the children were getting increased access to the speech signal as a result of their NLFC hearing aids (question 1), it would be possible to see improved performance in areas of speech production, morphosyntax, and speech perception compared with the group with conventional processing. Design Participants included 66 children with hearing loss recruited as part of a larger multisite National Institutes of Health–funded study, Outcomes for Children with Hearing Loss, designed to explore the developmental outcomes of children with mild to severe hearing loss. For the larger study, data on communication, academic and psychosocial skills were gathered in an accelerated longitudinal design, with entry into the study between 6 months and 7 years of age. Subjects in this report consisted of 3-, 4-, and 5-year-old children recruited at the North Carolina test site. All had at least at least 6 months of current hearing aid usage with their NLFC or conventional amplification. Demographic characteristics were compared at the three age levels as well as audibility and speech/language outcomes; speech-perception scores were compared for the 5-year-old groups. Results Results indicate that the audibility provided did not differ between the technology options. As a result, there was no difference between groups on speech or language outcome measures at 4 or 5 years of age, and no impact on speech perception (measured at 5 years of age). The difference in Comprehensive Assessment of Spoken Language and mean length of utterance scores for the 3-year-old group favoring the group with conventional amplification may be a consequence of confounding factors such as increased incidence of prematurity in the group using NLFC. Conclusions Children fit with NLFC had similar audibility, as measured by a modified Speech Intelligibility Index, compared with a matched group of children using conventional technology. In turn, there were no differences in their speech and language abilities. PMID:24892229

  16. Nonlinear frequency compression in hearing aids: impact on speech and language development.

    PubMed

    Bentler, Ruth; Walker, Elizabeth; McCreery, Ryan; Arenas, Richard M; Roush, Patricia

    2014-01-01

    The research questions of this study were: (1) Are children using nonlinear frequency compression (NLFC) in their hearing aids getting better access to the speech signal than children using conventional processing schemes? The authors hypothesized that children whose hearing aids provided wider input bandwidth would have more access to the speech signal, as measured by an adaptation of the Speech Intelligibility Index, and (2) are speech and language skills different for children who have been fit with the two different technologies; if so, in what areas? The authors hypothesized that if the children were getting increased access to the speech signal as a result of their NLFC hearing aids (question 1), it would be possible to see improved performance in areas of speech production, morphosyntax, and speech perception compared with the group with conventional processing. Participants included 66 children with hearing loss recruited as part of a larger multisite National Institutes of Health-funded study, Outcomes for Children with Hearing Loss, designed to explore the developmental outcomes of children with mild to severe hearing loss. For the larger study, data on communication, academic and psychosocial skills were gathered in an accelerated longitudinal design, with entry into the study between 6 months and 7 years of age. Subjects in this report consisted of 3-, 4-, and 5-year-old children recruited at the North Carolina test site. All had at least at least 6 months of current hearing aid usage with their NLFC or conventional amplification. Demographic characteristics were compared at the three age levels as well as audibility and speech/language outcomes; speech-perception scores were compared for the 5-year-old groups. Results indicate that the audibility provided did not differ between the technology options. As a result, there was no difference between groups on speech or language outcome measures at 4 or 5 years of age, and no impact on speech perception (measured at 5 years of age). The difference in Comprehensive Assessment of Spoken Language and mean length of utterance scores for the 3-year-old group favoring the group with conventional amplification may be a consequence of confounding factors such as increased incidence of prematurity in the group using NLFC. Children fit with NLFC had similar audibility, as measured by a modified Speech Intelligibility Index, compared with a matched group of children using conventional technology. In turn, there were no differences in their speech and language abilities.

  17. Evaluation of the effects of nonlinear frequency compression on speech recognition and sound quality for adults with mild to moderate hearing loss.

    PubMed

    Picou, Erin M; Marcrum, Steven C; Ricketts, Todd A

    2015-03-01

    While potentially improving audibility for listeners with considerable high frequency hearing loss, the effects of implementing nonlinear frequency compression (NFC) for listeners with moderate high frequency hearing loss are unclear. The purpose of this study was to investigate the effects of activating NFC for listeners who are not traditionally considered candidates for this technology. Participants wore study hearing aids with NFC activated for a 3-4 week trial period. After the trial period, they were tested with NFC and with conventional processing on measures of consonant discrimination threshold in quiet, consonant recognition in quiet, sentence recognition in noise, and acceptableness of sound quality of speech and music. Seventeen adult listeners with symmetrical, mild to moderate sensorineural hearing loss participated. Better ear, high frequency pure-tone averages (4, 6, and 8 kHz) were 60 dB HL or better. Activating NFC resulted in lower (better) thresholds for discrimination of /s/, whose spectral center was 9 kHz. There were no other significant effects of NFC compared to conventional processing. These data suggest that the benefits, and detriments, of activating NFC may be limited for this population.

  18. Rolling ball sifting algorithm for the augmented visual inspection of carotid bruit auscultation

    NASA Astrophysics Data System (ADS)

    Huang, Adam; Lee, Chung-Wei; Liu, Hon-Man

    2016-07-01

    Carotid bruits are systolic sounds associated with turbulent blood flow through atherosclerotic stenosis in the neck. They are audible intermittent high-frequency (above 200 Hz) sounds mixed with background noise and transmitted low-frequency (below 100 Hz) heart sounds that wax and wane periodically. It is a nontrivial task to extract both bruits and heart sounds with high fidelity for further computer-aided auscultation and diagnosis. In this paper we propose a rolling ball sifting algorithm that is capable to filter signals with a sharper frequency selectivity mechanism in the time domain. By rolling two balls (one above and one below the signal) of a suitable radius, the balls are large enough to roll over bruits and yet small enough to ride on heart sound waveforms. The high-frequency bruits can then be extracted according to a tangibility criterion by using the local extrema touched by the balls. Similarly, the low-frequency heart sounds can be acquired by a larger radius. By visualizing the periodicity information of both the extracted heart sounds and bruits, the proposed visual inspection method can potentially improve carotid bruit diagnosis accuracy.

  19. Measurement of thin films using very long acoustic wavelengths

    NASA Astrophysics Data System (ADS)

    Clement, G. T.; Nomura, H.; Adachi, H.; Kamakura, T.

    2013-12-01

    A procedure for measuring material thickness by means of necessarily long acoustic wavelengths is examined. The approach utilizes a temporal phase lag caused by the impulse time of wave momentum transferred through a thin layer that is much denser than its surrounding medium. In air, it is predicted that solid or liquid layers below approximately 1/2000 of the acoustic wavelength will exhibit a phase shift with an arctangent functional dependence on thickness and layer density. The effect is verified for thin films on the scale of 10 μm using audible frequency sound (7 kHz). Soap films as thin as 100 nm are then measured using 40 kHz air ultrasound. The method's potential for imaging applications is demonstrated by combining the approach with near-field holography, resulting in reconstructions with sub-wavelength resolution in both the depth and lateral directions. Potential implications at very high and very low acoustic frequencies are discussed.

  20. Applications of sub-audible speech recognition based upon electromyographic signals

    NASA Technical Reports Server (NTRS)

    Jorgensen, C. Charles (Inventor); Betts, Bradley J. (Inventor)

    2009-01-01

    Method and system for generating electromyographic or sub-audible signals (''SAWPs'') and for transmitting and recognizing the SAWPs that represent the original words and/or phrases. The SAWPs may be generated in an environment that interferes excessively with normal speech or that requires stealth communications, and may be transmitted using encoded, enciphered or otherwise transformed signals that are less subject to signal distortion or degradation in the ambient environment.

  1. Infants' response to the audible and visible properties of the human face: II. Discrimination of differences between singing and adult-directed speech.

    PubMed

    Lewkowicz, D J

    1998-05-01

    Human infants' responsiveness to the audible and visible features of human faces was studied by habituating them to a person speaking a prepared script in an adult-directed manner and then administering a series of separate test trials where a person could be seen, heard, or seen and heard singing. When habituated to a female person speaking in an adult-directed manner and tested with a singing female 4, 6, and 8-month-old infants responded to the audible, visible, and bimodal changes, whereas 3-month-old infants only responded to the visual and bimodal changes. In contrast, when habituated to a male person speaking in an adult-directed manner and tested with a singing female, all age groups discriminated all three types of changes. These findings demonstrate that infants are responsive to differences between low- and high-prosody content inherent in both the facial and vocal characteristics of the human face and that, whereas responsiveness to the visible and bimodal features associated with differences between adult-directed speech and singing is present as early as 3 months of age, responsiveness to the audible features emerges between 3 and 4 months of age depending on whether gender differences are present as well.

  2. Near-threshold equal-loudness contours for harbor seals (Phoca vitulina) derived from reaction times during underwater audiometry: a preliminary study.

    PubMed

    Kastelein, Ronald A; Wensveen, Paul J; Terhune, John M; de Jong, Christ A F

    2011-01-01

    Equal-loudness functions describe relationships between the frequencies of sounds and their perceived loudness. This pilot study investigated the possibility of deriving equal-loudness contours based on the assumption that sounds of equal perceived loudness elicit equal reaction times (RTs). During a psychoacoustic underwater hearing study, the responses of two young female harbor seals to tonal signals between 0.125 and 100 kHz were filmed. Frame-by-frame analysis was used to quantify RT (the time between the onset of the sound stimulus and the onset of movement of the seal away from the listening station). Near-threshold equal-latency contours, as surrogates for equal-loudness contours, were estimated from RT-level functions fitted to mean RT data. The closer the received sound pressure level was to the 50% detection hearing threshold, the more slowly the animals reacted to the signal (RT range: 188-982 ms). Equal-latency contours were calculated relative to the RTs shown by each seal at sound levels of 0, 10, and 20 dB above the detection threshold at 1 kHz. Fifty percent detection thresholds are obtained with well-trained subjects actively listening for faint familiar sounds. When calculating audibility ranges of sounds for harbor seals in nature, it may be appropriate to consider levels 20 dB above this threshold.

  3. Speech Recognition and Parent Ratings From Auditory Development Questionnaires in Children Who Are Hard of Hearing.

    PubMed

    McCreery, Ryan W; Walker, Elizabeth A; Spratford, Meredith; Oleson, Jacob; Bentler, Ruth; Holte, Lenore; Roush, Patricia

    2015-01-01

    Progress has been made in recent years in the provision of amplification and early intervention for children who are hard of hearing. However, children who use hearing aids (HAs) may have inconsistent access to their auditory environment due to limitations in speech audibility through their HAs or limited HA use. The effects of variability in children's auditory experience on parent-reported auditory skills questionnaires and on speech recognition in quiet and in noise were examined for a large group of children who were followed as part of the Outcomes of Children with Hearing Loss study. Parent ratings on auditory development questionnaires and children's speech recognition were assessed for 306 children who are hard of hearing. Children ranged in age from 12 months to 9 years. Three questionnaires involving parent ratings of auditory skill development and behavior were used, including the LittlEARS Auditory Questionnaire, Parents Evaluation of Oral/Aural Performance in Children rating scale, and an adaptation of the Speech, Spatial, and Qualities of Hearing scale. Speech recognition in quiet was assessed using the Open- and Closed-Set Test, Early Speech Perception test, Lexical Neighborhood Test, and Phonetically Balanced Kindergarten word lists. Speech recognition in noise was assessed using the Computer-Assisted Speech Perception Assessment. Children who are hard of hearing were compared with peers with normal hearing matched for age, maternal educational level, and nonverbal intelligence. The effects of aided audibility, HA use, and language ability on parent responses to auditory development questionnaires and on children's speech recognition were also examined. Children who are hard of hearing had poorer performance than peers with normal hearing on parent ratings of auditory skills and had poorer speech recognition. Significant individual variability among children who are hard of hearing was observed. Children with greater aided audibility through their HAs, more hours of HA use, and better language abilities generally had higher parent ratings of auditory skills and better speech-recognition abilities in quiet and in noise than peers with less audibility, more limited HA use, or poorer language abilities. In addition to the auditory and language factors that were predictive for speech recognition in quiet, phonological working memory was also a positive predictor for word recognition abilities in noise. Children who are hard of hearing continue to experience delays in auditory skill development and speech-recognition abilities compared with peers with normal hearing. However, significant improvements in these domains have occurred in comparison to similar data reported before the adoption of universal newborn hearing screening and early intervention programs for children who are hard of hearing. Increasing the audibility of speech has a direct positive effect on auditory skill development and speech-recognition abilities and also may enhance these skills by improving language abilities in children who are hard of hearing. Greater number of hours of HA use also had a significant positive impact on parent ratings of auditory skills and children's speech recognition.

  4. Contribution of low-frequency harmonics to Mandarin Chinese tone identification in quiet and six-talker babble background.

    PubMed

    Liu, Chang; Azimi, Behnam; Bhandary, Moulesh; Hu, Yi

    2014-01-01

    The goal of this study was to investigate Mandarin Chinese tone identification in quiet and multi-talker babble conditions for normal-hearing listeners. Tone identification was measured with speech stimuli and stimuli with low and/or high harmonics that were embedded in three Mandarin vowels with two fundamental frequencies. There were six types of stimuli: all harmonics (All), low harmonics (Low), high harmonics (High), and the first (H1), second (H2), and third (H3) harmonic. Results showed that, for quiet conditions, individual harmonics carried frequency contour information well enough for tone identification with high accuracy; however, in noisy conditions, tone identification with individual low harmonics (e.g., H1, H2, and H3) was significantly lower than that with the Low, High, and All harmonics. Moreover, tone identification with individual harmonics in noise was lower for a low F0 than for a high F0, and was also dependent on vowel category. Tone identification with individual low-frequency harmonics was accounted for by local signal-to-noise ratios, indicating that audibility of harmonics in noise may play a primary role in tone identification.

  5. Transferring Data from Smartwatch to Smartphone through Mechanical Wave Propagation.

    PubMed

    Kim, Seung-Chan; Lim, Soo-Chul

    2015-08-28

    Inspired by the mechanisms of bone conduction transmission, we present a novel sensor and actuation system that enables a smartwatch to securely communicate with a peripheral touch device, such as a smartphone. Our system regards hand structures as a mechanical waveguide that transmits particular signals through mechanical waves. As a signal, we used high-frequency vibrations (18.0-20.0 kHz) so that users cannot sense the signals either tactually or audibly. To this end, we adopted a commercial surface transducer, which is originally developed as a bone-conduction actuator, for mechanical signal generation. At the receiver side, a piezoelement was adopted for picking up the transferred mechanical signals. Experimental results have shown that the proposed system can successfully transfer data using mechanical waves. We also validate dual-frequency actuations under which high-frequency signals (18.0-20.0 kHz) are generated along with low-frequency (up to 250 Hz) haptic vibrations. The proposed method has advantages in terms of security in that it does not reveal the signals outside the body, meaning that it is not possible for attackers to eavesdrop on the signals. To further illustrate the possible application spaces, we conclude with explorations of the proposed approach.

  6. The homogeneity of audibility and prosody of Zulu words for speech reception threshold (SRT) testing.

    PubMed

    Panday, Seema; Kathard, Harsha; Pillay, Mershen; Govender, Cyril

    2009-01-01

    The aim of this investigation was to determine which of 58 preselected Zulu words developed by Panday et al. (2007) could be used for Speech Reception Threshold (SRT) testing. To realize this aim the homogeneity of audibility of 58 bisyllabic Zulu low tone verbs was measured, followed by an analysis of the prosodic features of the selected words. The words were digitally recorded by a Zulu first language male speaker and presented at 6 intensity levels to 30 Zulu first language speakers (18-25 years, mean age of 21.5 years), whose hearing was normal. Homogeneity of audibility was determined by employing logistic regression analysis. Twenty eight words met the criterion of homogeneity of audibility. This was evidenced by a mean slope of 50% at 5.98%/dB. The prosodic features of the twenty eight words were further analyzed using a computerized speech laboratory system. The findings confirmed that the pitch contours of the words followed the prosodic pattern apparent within Zulu linguistic structure. Eighty nine percent of the Zulu verbs were found to have a difference in the pitch pattern between the two syllables i.e. the first syllable was low in pitch, while the second syllable was high in pitch. It emerged that the twenty eight words could be used for establishing SRT within a normal hearing Zulu speaking population. Further research within clinical populations is recommended.

  7. Apparatus for detecting the presence of a liquid

    DOEpatents

    Kronberg, James W.

    1995-01-01

    An apparatus for detecting the presence of a liquid in a region, including an electrically passive sensor adapted for contacting the liquid, and an electrically active detector. The sensor is a circuit with a pair of spaced-apart terminals connected to a switch that closes in the presence of the liquid. The detector carries an alternating current with a resonant frequency. When the sensor is placed in a region and liquid is present in the region, the circuit of the sensor is closed. By bringing the detector close to the sensor, an alternating current is induced in the sensor that will, in turn, alter the resonant frequency of the detector. The change in the resonant frequency is signaled by a transducer. The switch can operate by a change in conductivity of a material between the terminals of the sensor or by expansion of a liquid absorber that pushes the two terminals together, or by a change in the conductivity of the space between the terminals as a result of the presence of the liquid. The detector generates an audible or visible signal, or both, in response to the change in current.

  8. Vibration amplitude sonoelastography lesion imaging using low-frequency audible vibration

    NASA Astrophysics Data System (ADS)

    Taylor, Lawrence; Parker, Kevin

    2003-04-01

    Sonoelastography or vibration amplitude imaging is an ultrasound imaging technique in which low-amplitude, low-frequency shear waves, less than 0.1-mm displacement and 1-kHz frequency, are propagated deep into tissue, while real time Doppler techniques are used to image the resulting vibration pattern. Finite-element studies and experiments on tissue-mimicking phantoms verify that a discrete hard inhomogeneity present within a larger region of soft tissue will cause a decrease in the vibration field at its location. This forms the basis for tumor detection using sonoelastography. Real time relative imaging of the vibration field is possible because a vibrating particle will phase modulate an ultrasound signal. The particle's amplitude is directly proportional to the spectral spread of the reflected Doppler echo. Real time estimation of the variance of the Doppler power spectrum at each pixel allows the vibration field to be imaged. Results are shown for phantom lesions, thermal lesions, and 3-D in vitro and 2-D in vivo prostate cancer. MRI and whole mount histology is used to validate the system accuracy.

  9. Effect of real-world sounds on protein crystallization.

    PubMed

    Zhang, Chen-Yan; Liu, Yue; Tian, Xu-Hua; Liu, Wen-Jing; Li, Xiao-Yu; Yang, Li-Xue; Jiang, Han-Jun; Han, Chong; Chen, Ke-An; Yin, Da-Chuan

    2018-06-01

    Protein crystallization is sensitive to the environment, while audible sound, as a physical and environmental factor during the entire process, is always ignored. We have previously reported that protein crystallization can be affected by a computer-generated monotonous sound with fixed frequency and amplitude. However, real-world sounds are not so simple but are complicated by parameters (frequency, amplitude, timbre, etc.) that vary over time. In this work, from three sound categories (music, speech, and environmental sound), we selected 26 different sounds and evaluated their effects on protein crystallization. The correlation between the sound parameters and the crystallization success rate was studied mathematically. The results showed that the real-world sounds, similar to the artificial monotonous sounds, could not only affect protein crystallization, but also improve crystal quality. Crystallization was dependent not only on the frequency, amplitude, volume, irradiation time, and overall energy of the sounds but also on their spectral characteristics. Based on these results, we suggest that intentionally applying environmental sound may be a simple and useful tool to promote protein crystallization. Copyright © 2018. Published by Elsevier B.V.

  10. World Record Magnetic Field 100T

    ScienceCinema

    McDonald, Ross; Mielke, Chuck; Rickel, Dwight

    2018-01-16

    Scientists at the Los Alamos National Laboratory campus of the National High Magnetic Field Laboratory have successfully produced the world's first 100 Tesla non-destructive magnetic field. The achievement was decades in the making, involving a diverse team of scientists and engineers. The 100 Tesla mark was reached at approximately 3:30 p.m. on March 22, 2012. A note about the sound you'll hear when the magnet is energized: The sound that the 100 T multi-shot magnet makes is due to the electrical current modulation from the 3 phase power converters (known as 12 pulse converters) and the harmonics associated with the chopping of the sinusoidal input power. The magnet vibrates at the electrical current frequencies multiplied by 12 (i.e. ~ 55 Hz x 12 = 660 Hz) hence making an audible sound. The generator is not run at full speed (1650 RPM instead of 1800 RPM) so the frequency is slightly lower than US Line frequency (i.e. 55 Hz instead of 60 Hz). A spectrograph of the sound from the magnet pulse shows the multiple harmonics as reddish horizontal bands as a function of time.

  11. Rapidly deployable emergency communication system

    DOEpatents

    Gladden, Charles A.; Parelman, Martin H.

    1979-01-01

    A highly versatile, highly portable emergency communication system which permits deployment in a very short time to cover both wide areas and distant isolated areas depending upon mission requirements. The system employs a plurality of lightweight, fully self-contained repeaters which are deployed within the mission area to provide communication between field teams, and between each field team and a mobile communication control center. Each repeater contains a microcomputer controller, the program for which may be changed from the control center by the transmission of digital data within the audible range (300-3,000 Hz). Repeaters are accessed by portable/mobile transceivers, other repeaters, and the control center through the transmission and recognition of digital data code words in the subaudible range.

  12. Far Forward Life Support System (FFLSS) Phase II

    DTIC Science & Technology

    2001-05-01

    button will clear audible, flashing , or constant red alarms. Pushing the Config button drops down to the Level 2 menu (bottom line of Figure 8). In...disabled. Again, with testing this audible noise can be disabled. The visual flashing or constant red cannot be disabled. Pushing Return goes back to Level...Calling PLOTPIXEL( x ,y) and PLOTLINE(xl,x2,yl,y2) is as simple as pushing the appropriate bytes (unsigned integers) onto the stack and jumping to the

  13. Is it necessary to occlude the ear in bone-conduction testing at 4 kHz, in order to prevent air-borne radiation affecting the results?

    PubMed

    Tate Maltby, Maryanne; Gaszczyk, David

    2015-01-01

    To re-evaluate the current BSA recommendation that the test ear should be occluded during the bone-conduction procedure at frequencies above 2 kHz to prevent audible air-borne radiation. Pure-tone audiometry was undertaken during routine hearing tests. The audiograms of fifty-two ears met the criteria for the study and were included. Bone conduction at 4 kHz was tested in three different conditions: test ear open/occluded by earplug and occluded by circumaural earphone. Forty-four adults aged 41-77 years with average hearing levels from normal to severe loss. All complied fully with the test procedure. No audiogram had a significant conductive element. There was no significant difference in each of the three test situations. Only two audiograms showed any (5 dB) difference at 4 kHz when bone conduction was retested with the ear occluded. The errors that result in a false air-bone gap at 4 kHz would not appear to be due to air-borne radiation. Failure to occlude the ear canal at 4 kHz, where air-borne radiation is greatest, makes no significant difference to the audiometric results. It is therefore suggested that it is unnecessary to block the test ear during routine pure-tone bone-conduction testing to prevent audible air-borne radiation, and that this should no longer form part of normal clinical practice.

  14. Ultrathin thermoacoustic nanobridge loudspeakers from ALD on polyimide

    NASA Astrophysics Data System (ADS)

    Brown, J. J.; Moore, N. C.; Supekar, O. D.; Gertsch, J. C.; Bright, V. M.

    2016-11-01

    The recent development of low-temperature (<200 °C) atomic layer deposition (ALD) for fabrication of freestanding nanostructures has enabled consideration of active device design based on engineered ultrathin films. This paper explores audible sound production from thermoacoustic loudspeakers fabricated from suspended tungsten nanobridges formed by ALD. Additionally, this paper develops an approach to lumped-element modeling for design of thermoacoustic nanodevices and relates the near-field plane wave model of individual transducer beams to the far-field spherical wave sound pressure that can be measured with standard experimental techniques. Arrays of suspended nanobridges with 25.8 nm thickness and sizes as small as 17 μm × 2 μm have been fabricated and demonstrated to produce audible sound using the thermoacoustic effect. The nanobridges were fabricated by ALD of 6.5 nm Al2O3 and 19.3 nm tungsten on sacrificial polyimide, with ALD performed at 130 °C and patterned by standard photolithography. The maximum observed loudspeaker sound pressure level (SPL) is 104 dB, measured at 20 kHz, 9.71 W input power, and 1 cm measurement distance, providing a loudspeaker sensitivity value of ∼64.6 dB SPL/1 mW. Sound production efficiency was measured to vary proportional to frequency f 3 and was directly proportional to input power. The devices in this paper demonstrate industrially feasible nanofabrication of thermoacoustic transducers and a sound production mechanism pertinent to submicron-scale device engineering.

  15. A Precision, Low-Cost GPS-Based Synchronization Scheme for Improved AM Reception.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Stephen Fulton; Moore, Anthony

    2009-01-01

    This paper describes a highly accurate carrier-frequency synchronization scheme for actively, automatically locking multiple, remotely located AM broadcast transmitters to a common frequency/timing reference source such as GPS. The extremely tight frequency lock (to ~1 part in 109 or better) permits the effective elimination of audible and even sub-audible beats between the local (desired) station s carrier signal and the distant stations carriers, usually received via skywave propagation during the evening and nighttime hours. These carrier-beat components cause annoying modulations of the desired station s audio at the receiver and concurrent distortion of the audio modulation from the distant station(s)more » and often cause listeners to tune out due to the poor reception quality. Significant reduction or elimination of the beats and related effects will greatly enlarge the effective (interference-limited) listening area of the desired station (from 4 to 10 times as indicated in our tests) and simultaneously reduce the corresponding interference of the local transmitter to the distant stations as well. In addition, AM stereo (CQUAM) reception will be particularly improved by minimizing the phase shifts induced by co-channel interfering signals; HD will also benefit via reduction in beats from analog signals. The automatic frequency-control hardware described is inexpensive ($1-2K), requires no periodic recalibration, has essentially zero long-term drift, and could employ alternate wide-area frequency references of suitable accuracy, including broadcasts from WWVB, LORAN-C, and equivalent sources. The basic configuration of the GPS-disciplined oscillator which solves this problem is extremely simple. The main oscillator is a conventional high-stability quartz-crystal type. To counter long-term drifts, the oscillator is slightly adjusted to track a high-precision source of standard frequency obtained from a specialized GPS receiver (or other source), usually at 10.000 MHz. This very stable local reference frequency is then used as a clock for a standard digitally implemented frequency synthesizer, which is programmed to generate the specific (AM broadcast) transmitter carrier frequency desired. The stability of the disciplining source, typically ~ 1 part in 109 to 1011, is thus transferred to the final AM transmitter carrier output frequency. Generally, an AM radio listener during the evening and nighttime hours, and to a lesser extent in the early morning, receives undesired skywave signals from several distant stations as well as the desired local (groundwave) signal. If all of these signals are within about 0.01-0.001 Hz of each other, any resulting carrier beats will be of such long periods that the beats will be effectively suppressed by the action of the receiver s AGC circuitry and thus be unnoticeable to the listener. Many modern, synthesizer-based transmitters can directly lock to the precision disciplined 10-MHz source, while older units usually require references at either1 e, 2 e, or 4 e the final frequency. In these latter cases, the existing transmitter crystal can usually be satisfactorily pulled via injection locking. The effectiveness of the synchronization concept to reduce interference effects was demonstrated in a laboratory test setup. Many hours of careful subjective listening were conducted, with the two interfering units both precisely on-frequency with the main unit (synchronous operation) and with the two interferers at various frequency offsets, from below 1 Hz to above 10 Hz.« less

  16. Blink rate, incomplete blinks and computer vision syndrome.

    PubMed

    Portello, Joan K; Rosenfield, Mark; Chu, Christina A

    2013-05-01

    Computer vision syndrome (CVS), a highly prevalent condition, is frequently associated with dry eye disorders. Furthermore, a reduced blink rate has been observed during computer use. The present study examined whether post task ocular and visual symptoms are associated with either a decreased blink rate or a higher prevalence of incomplete blinks. An additional trial tested whether increasing the blink rate would reduce CVS symptoms. Subjects (N = 21) were required to perform a continuous 15-minute reading task on a desktop computer at a viewing distance of 50 cm. Subjects were videotaped during the task to determine their blink rate and amplitude. Immediately after the task, subjects completed a questionnaire regarding ocular symptoms experienced during the trial. In a second session, the blink rate was increased by means of an audible tone that sounded every 4 seconds, with subjects being instructed to blink on hearing the tone. The mean blink rate during the task without the audible tone was 11.6 blinks per minute (SD, 7.84). The percentage of blinks deemed incomplete for each subject ranged from 0.9 to 56.5%, with a mean of 16.1% (SD, 15.7). A significant positive correlation was observed between the total symptom score and the percentage of incomplete blinks during the task (p = 0.002). Furthermore, a significant negative correlation was noted between the blink score and symptoms (p = 0.035). Increasing the mean blink rate to 23.5 blinks per minute by means of the audible tone did not produce a significant change in the symptom score. Whereas CVS symptoms are associated with a reduced blink rate, the completeness of the blink may be equally significant. Because instructing a patient to increase his or her blink rate may be ineffective or impractical, actions to achieve complete corneal coverage during blinking may be more helpful in alleviating symptoms during computer operation.

  17. Beaconing Signalization Substantially Reduces Blind Pedestrians’ Veer on Snow-Covered Pavement

    PubMed Central

    Guth, David A.; Long, Richard G.; Kim, Dae Shik; Robertson, Elizabeth A.; Reesor, Abbie L.; Bacik, Catherine J.; Eckert, Jaclyn M.

    2017-01-01

    Veering outside of crosswalks is a common problem experienced by individuals who are blind. One technology found to be effective for reducing this veer when other guidance cues are absent is audible beaconing. However, veering in general and veering from crosswalks in particular have been studied primarily on smooth, flat walking surfaces such as clear pavement. This experiment compared veering on clear pavement with veering on snow-covered pavement, with and without audible beaconing. Eleven blind participants traveling with long canes attempted to walk a straight path for 72 ft (21.9 m), a typical length of a six-lane crosswalk. Beaconing substantially reduced veering at 36 ft (11.0 m) and 72 ft from the starting point and enabled participants to remain within a simulated crosswalk. Walking on snow was not found to affect veering but did increase the number of steps taken. The findings suggest that in snowy and clear conditions alike, audible beaconing is an effective wayfinding tool for intersections equipped with accessible pedestrian signals. PMID:29307955

  18. Short-Term and Working Memory Impairments in Early-Implanted, Long-Term Cochlear Implant Users Are Independent of Audibility and Speech Production

    PubMed Central

    AuBuchon, Angela M.; Pisoni, David B.; Kronenberger, William G.

    2015-01-01

    OBJECTIVES Determine if early-implanted, long-term cochlear implant (CI) users display delays in verbal short-term and working memory capacity when processes related to audibility and speech production are eliminated. DESIGN Twenty-three long-term CI users and 23 normal-hearing controls each completed forward and backward digit span tasks under testing conditions which differed in presentation modality (auditory or visual) and response output (spoken recall or manual pointing). RESULTS Normal-hearing controls reproduced more lists of digits than the CI users, even when the test items were presented visually and the responses were made manually via touchscreen response. CONCLUSIONS Short-term and working memory delays observed in CI users are not due to greater demands from peripheral sensory processes such as audibility or from overt speech-motor planning and response output organization. Instead, CI users are less efficient at encoding and maintaining phonological representations in verbal short-term memory utilizing phonological and linguistic strategies during memory tasks. PMID:26496666

  19. Short-Term and Working Memory Impairments in Early-Implanted, Long-Term Cochlear Implant Users Are Independent of Audibility and Speech Production.

    PubMed

    AuBuchon, Angela M; Pisoni, David B; Kronenberger, William G

    2015-01-01

    To determine whether early-implanted, long-term cochlear implant (CI) users display delays in verbal short-term and working memory capacity when processes related to audibility and speech production are eliminated. Twenty-three long-term CI users and 23 normal-hearing controls each completed forward and backward digit span tasks under testing conditions that differed in presentation modality (auditory or visual) and response output (spoken recall or manual pointing). Normal-hearing controls reproduced more lists of digits than the CI users, even when the test items were presented visually and the responses were made manually via touchscreen response. Short-term and working memory delays observed in CI users are not due to greater demands from peripheral sensory processes such as audibility or from overt speech-motor planning and response output organization. Instead, CI users are less efficient at encoding and maintaining phonological representations in verbal short-term memory using phonological and linguistic strategies during memory tasks.

  20. Beaconing Signalization Substantially Reduces Blind Pedestrians' Veer on Snow-Covered Pavement.

    PubMed

    Guth, David A; Long, Richard G; Kim, Dae Shik; Robertson, Elizabeth A; Reesor, Abbie L; Bacik, Catherine J; Eckert, Jaclyn M

    2017-01-01

    Veering outside of crosswalks is a common problem experienced by individuals who are blind. One technology found to be effective for reducing this veer when other guidance cues are absent is audible beaconing. However, veering in general and veering from crosswalks in particular have been studied primarily on smooth, flat walking surfaces such as clear pavement. This experiment compared veering on clear pavement with veering on snow-covered pavement, with and without audible beaconing. Eleven blind participants traveling with long canes attempted to walk a straight path for 72 ft (21.9 m), a typical length of a six-lane crosswalk. Beaconing substantially reduced veering at 36 ft (11.0 m) and 72 ft from the starting point and enabled participants to remain within a simulated crosswalk. Walking on snow was not found to affect veering but did increase the number of steps taken. The findings suggest that in snowy and clear conditions alike, audible beaconing is an effective wayfinding tool for intersections equipped with accessible pedestrian signals.

  1. The effects of audibility and novel word learning ability on vocabulary level in children with cochlear implants.

    PubMed

    Davidson, Lisa S; Geers, Ann E; Nicholas, Johanna G

    2014-07-01

    A novel word learning (NWL) paradigm was used to explore underlying phonological and cognitive mechanisms responsible for delayed vocabulary level in children with cochlear implants (CIs). One hundred and one children using CIs, 6-12 years old, were tested along with 47 children with normal hearing (NH). Tests of NWL, receptive vocabulary, and speech perception at 2 loudness levels were administered to children with CIs. Those with NH completed the NWL task and a receptive vocabulary test. CI participants with good audibility (GA) versus poor audibility (PA) were compared on all measures. Analysis of variance was used to compare performance across the children with NH and the two groups of children with CIs. Multiple regression analysis was employed to identify independent predictors of vocabulary outcomes. Children with CIs in the GA group scored higher in receptive vocabulary and NWL than children in the PA group, although they did not reach NH levels. CI-aided pure tone threshold and performance on the NWL task predicted independent variance in vocabulary after accounting for other known predictors. Acquiring spoken vocabulary is facilitated by GA with a CI and phonological learning and memory skills. Children with CIs did not learn novel words at the same rate or achieve the same receptive vocabulary levels as their NH peers. Maximizing audibility for the perception of speech and direct instruction of new vocabulary may be necessary for children with CIs to reach levels seen in peers with NH.

  2. Speech recognition and parent-ratings from auditory development questionnaires in children who are hard of hearing

    PubMed Central

    McCreery, Ryan W.; Walker, Elizabeth A.; Spratford, Meredith; Oleson, Jacob; Bentler, Ruth; Holte, Lenore; Roush, Patricia

    2015-01-01

    Objectives Progress has been made in recent years in the provision of amplification and early intervention for children who are hard of hearing. However, children who use hearing aids (HA) may have inconsistent access to their auditory environment due to limitations in speech audibility through their HAs or limited HA use. The effects of variability in children’s auditory experience on parent-report auditory skills questionnaires and on speech recognition in quiet and in noise were examined for a large group of children who were followed as part of the Outcomes of Children with Hearing Loss study. Design Parent ratings on auditory development questionnaires and children’s speech recognition were assessed for 306 children who are hard of hearing. Children ranged in age from 12 months to 9 years of age. Three questionnaires involving parent ratings of auditory skill development and behavior were used, including the LittlEARS Auditory Questionnaire, Parents Evaluation of Oral/Aural Performance in Children Rating Scale, and an adaptation of the Speech, Spatial and Qualities of Hearing scale. Speech recognition in quiet was assessed using the Open and Closed set task, Early Speech Perception Test, Lexical Neighborhood Test, and Phonetically-balanced Kindergarten word lists. Speech recognition in noise was assessed using the Computer-Assisted Speech Perception Assessment. Children who are hard of hearing were compared to peers with normal hearing matched for age, maternal educational level and nonverbal intelligence. The effects of aided audibility, HA use and language ability on parent responses to auditory development questionnaires and on children’s speech recognition were also examined. Results Children who are hard of hearing had poorer performance than peers with normal hearing on parent ratings of auditory skills and had poorer speech recognition. Significant individual variability among children who are hard of hearing was observed. Children with greater aided audibility through their HAs, more hours of HA use and better language abilities generally had higher parent ratings of auditory skills and better speech recognition abilities in quiet and in noise than peers with less audibility, more limited HA use or poorer language abilities. In addition to the auditory and language factors that were predictive for speech recognition in quiet, phonological working memory was also a positive predictor for word recognition abilities in noise. Conclusions Children who are hard of hearing continue to experience delays in auditory skill development and speech recognition abilities compared to peers with normal hearing. However, significant improvements in these domains have occurred in comparison to similar data reported prior to the adoption of universal newborn hearing screening and early intervention programs for children who are hard of hearing. Increasing the audibility of speech has a direct positive effect on auditory skill development and speech recognition abilities, and may also enhance these skills by improving language abilities in children who are hard of hearing. Greater number of hours of HA use also had a significant positive impact on parent ratings of auditory skills and children’s speech recognition. PMID:26731160

  3. Effects of infrasound on vestibular function

    NASA Astrophysics Data System (ADS)

    Takigawa, H.; Sakamoto, H.; Murata, M.

    1991-12-01

    The present study was undertaken to elucidate subjective symptoms reported by some individuals exposed to various sounds, including infrasound. Narrow band infrasound of 5 Hz at center frequency and wide octave band audible noise were separately applied at an intensity of 95 dB. Parameters such as involuntary eye movement with the eyes visually fixed, body sway and pulse-wave were investigated. The total amount and power percentage in the low-frequency band of involuntary eye movement was significantly increased upon exposure to infrasound. Furthermore, confusion in postural control at the time of transition from opening to closing of the subject's eyes was inhibited by this exposure. Conversely, pulse-wave height decrement was observed upon exposure to both sounds, although this was smaller in the case of infrasound as compared with that of noise. These findings are taken to indicate that the effects taking place via the two different pathways were mixed in the subjective symptoms, and that functional changes caused by infrasound exposure were unrelated to an emotion stimulated by acoustical sensation.

  4. The effect of talocrural joint manipulation on range of motion at the ankle.

    PubMed

    Fryer, Gary A; Mudge, Jacob M; McLaughlin, Patrick A

    2002-01-01

    To determine whether a single high-velocity, low-amplitude thrust manipulation to the talocrural joint altered ankle range of motion. A randomized, controlled and blinded study. Asymptomatic male and female volunteers (N = 41). Subjects were randomly assigned into either an experimental group (n = 20) or a control group (n = 21). Both ankles of subjects in the experimental group were manipulated by using a single high-velocity, low-amplitude thrust to the talocrural joint. Pretest and posttest measurements of passive dorsiflexion range of motion were taken. No significant changes in dorsiflexion range of motion were detected between manipulated ankles and those of control subjects. A significantly greater pretest dorsiflexion range of motion existed in those ankles in which manipulation produced an audible cavitation. Manipulation of the ankle does not increase dorsiflexion range of motion in asymptomatic subjects. Ankles that displayed a greater pretest range of dorsiflexion were more likely to cavitate, raising the possibility that ligament laxity may be associated with the tendency for ankles to cavitate.

  5. Evaluation of small arms noise in a natural soundscape-Bear Butte, SD

    NASA Astrophysics Data System (ADS)

    Braslau, David

    2005-09-01

    Most studies on soundscape intrusion have been limited to moving sources. Of less concern is noise from small arms. Potential impact was predicted from a proposed large small arms facility with 10000 rounds or more per day on the natural soundscape at Bear Butte, one of the most sacred sites of the Northern Cheyenne and other tribes. The primary impacted activity is meditation and oneness with the natural environment that can continue for several days through day and night. Non-natural sources included limited vehicles on a nearby highway and farm equipment, but few aircraft. Second-by-second ambient octave band readings were taken at 20 sites starting before sunrise. The minimum ambient level observed was 19.6 dBA but limits were encountered with a 1/2 in. microphone. Sound level data on small arms were projected from the proposed range four miles north of Bear Butte to elevated points on the Butte assuming a zero wind environment. Impact was evaluated using audibility, intrusiveness and impulse-weighted DNL. Projected levels were well above ambient. While the DNL was projected to increase by 15 dBA, this metric has little meaning for this type of activity. Assumptions related to outdoor sound propagation, audibility and impulsive noise perception are discussed.

  6. Drilling and operational sounds from an oil production island in the ice-covered Beaufort sea.

    PubMed

    Blackwell, Susanna B; Greene, Charles R; Richardson, W John

    2004-11-01

    Recordings of sounds underwater and in air, and of iceborne vibrations, were obtained at Northstar Island, an artificial gravel island in the Beaufort Sea near Prudhoe Bay (Alaska). The aim was to document the levels, characteristics, and range dependence of sounds and vibrations produced by drilling and oil production during the winter, when the island was surrounded by shore-fast ice. Drilling produced the highest underwater broadband (10-10,000 Hz) levels (maximum= 124 dB re: 1 microPa at 1 km), and mainly affected 700-1400 Hz frequencies. In contrast, drilling did not increase broadband levels in air or ice relative to levels during other island activities. Production did not increase broadband levels for any of the sensors. In all media, broadband levels decreased by approximately 20 dB/tenfold change in distance. Background levels underwater were reached by 9.4 km during drilling and 3-4 km without. In the air and ice, background levels were reached 5-10 km and 2-10 km from Northstar, respectively, depending on the wind but irrespective of drilling. A comparison of the recorded sounds with harbor and ringed seal audiograms showed that Northstar sounds were probably audible to seals, at least intermittently, out to approximately 1.5 km in water and approximately 5 km in air.

  7. A MEMS Condenser Microphone-Based Intracochlear Acoustic Receiver.

    PubMed

    Pfiffner, Flurin; Prochazka, Lukas; Peus, Dominik; Dobrev, Ivo; Dalbert, Adrian; Sim, Jae Hoon; Kesterke, Rahel; Walraevens, Joris; Harris, Francesca; Roosli, Christof; Obrist, Dominik; Huber, Alexander

    2017-10-01

    Intracochlear sound pressure (ICSP) measurements are limited by the small dimensions of the human inner ear and the requirements imposed by the liquid medium. A robust intracochlear acoustic receiver (ICAR) for repeated use with a simple data acquisition system that provides the required high sensitivity and small dimensions does not yet exist. The work described in this report aims to fill this gap and presents a new microelectromechanical systems (MEMS) condenser microphone (CMIC)-based ICAR concept suitable for ICSP measurements in human temporal bones. The ICAR head consisted of a passive protective diaphragm (PD) sealing the MEMS CMIC against the liquid medium, enabling insertion into the inner ear. The components of the MEMS CMIC-based ICAR were expressed by a lumped element model (LEM) and compared to the performance of successfully fabricated ICARs. Good agreement was achieved between the LEM and the measurements with different sizes of the PD. The ICSP measurements in a human cadaver temporal bone yielded data in agreement with the literature. Our results confirm that the presented MEMS CMIC-based ICAR is a promising technology for measuring ICSP in human temporal bones in the audible frequency range. A sensor for evaluation of the biomechanical hearing process by quantification of ICSP is presented. The concept has potential as an acoustic receiver in totally implantable cochlear implants.

  8. Transferring Data from Smartwatch to Smartphone through Mechanical Wave Propagation

    PubMed Central

    Kim, Seung-Chan; Lim, Soo-Chul

    2015-01-01

    Inspired by the mechanisms of bone conduction transmission, we present a novel sensor and actuation system that enables a smartwatch to securely communicate with a peripheral touch device, such as a smartphone. Our system regards hand structures as a mechanical waveguide that transmits particular signals through mechanical waves. As a signal, we used high-frequency vibrations (18.0–20.0 kHz) so that users cannot sense the signals either tactually or audibly. To this end, we adopted a commercial surface transducer, which is originally developed as a bone-conduction actuator, for mechanical signal generation. At the receiver side, a piezoelement was adopted for picking up the transferred mechanical signals. Experimental results have shown that the proposed system can successfully transfer data using mechanical waves. We also validate dual-frequency actuations under which high-frequency signals (18.0–20.0 kHz) are generated along with low-frequency (up to 250 Hz) haptic vibrations. The proposed method has advantages in terms of security in that it does not reveal the signals outside the body, meaning that it is not possible for attackers to eavesdrop on the signals. To further illustrate the possible application spaces, we conclude with explorations of the proposed approach. PMID:26343674

  9. High-frequency amplification and sound quality in listeners with normal through moderate hearing loss.

    PubMed

    Ricketts, Todd A; Dittberner, Andrew B; Johnson, Earl E

    2008-02-01

    One factor that has been shown to greatly affect sound quality is audible bandwidth. Provision of gain for frequencies above 4-6 kHz has not generally been supported for groups of hearing aid wearers. The purpose of this study was to determine if preference for bandwidth extension in hearing aid processed sounds was related to the magnitude of hearing loss in individual listeners. Ten participants with normal hearing and 20 participants with mild-to-moderate hearing loss completed the study. Signals were processed using hearing aid-style compression algorithms and filtered using two cutoff frequencies, 5.5 and 9 kHz, which were selected to represent bandwidths that are achievable in modern hearing aids. Round-robin paired comparisons based on the criteria of preferred sound quality were made for 2 different monaurally presented brief sound segments, including music and a movie. Results revealed that preference for either the wider or narrower bandwidth (9- or 5.5-kHz cutoff frequency, respectively) was correlated with the slope of hearing loss from 4 to 12 kHz, with steep threshold slopes associated with preference for narrower bandwidths. Consistent preference for wider bandwidth is present in some listeners with mild-to-moderate hearing loss.

  10. "Ring" in the solo child singing voice.

    PubMed

    Howard, David M; Williams, Jenevora; Herbst, Christian T

    2014-03-01

    Listeners often describe the voices of solo child singers as being "pure" or "clear"; these terms would suggest that the voice is not only pleasant but also clearly audible. The audibility or clarity could be attributed to the presence of high-frequency partials in the sound: a "brightness" or "ring." This article aims to investigate spectrally the acoustic nature of this ring phenomenon in children's solo voices, and in particular, relating it to their "nonring" production. Additionally, this is set in the context of establishing to what extent, if any, the spectral characteristics of ring are shared with those of the singer's formant cluster associated with professional adult opera singers in the 2.5-3.5kHz region. A group of child solo singers, acknowledged as outstanding by a singing teacher who specializes in teaching professional child singers, were recorded in a major UK concert hall performing Come unto him, all ye that labour, from the aria He shall feed his flock from The Messiah by GF Handel. Their singing was accompanied by a recording of a piano played through in-ear headphones. Sound pressure recordings were made from well within the critical distance in the hall. The singers were observed to produce notes with and without ring, and these recordings were analyzed in the frequency domain to investigate their spectra. The results indicate that there is evidence to suggest that ring in child solo singers is carried in two areas of the output spectrum: first in the singer's formant cluster region, centered around 4kHz, which is more than 1000Hz higher than what is observed in adults; and second in the region around 7.5-11kHz where a significant strengthening of harmonic presence is observed. A perceptual test has been carried out demonstrating that 94% of 62 listeners label a synthesized version of the calculated overall average ring spectrum for all subjects as having ring when compared with a synthesized version of the calculated overall average nonring spectrum. The notion of ring in the child solo voice manifests itself not only with spectral features in common with the projection peak found in adult singers but also in a higher frequency region. It is suggested that the formant cluster at around 4kHz is the children's equivalent of the singers' formant cluster; the frequency is higher than in the adult, most likely due to the smaller dimensions of the epilaryngeal tube. The frequency cluster observed as a strong peak at about 7.5-11kHz, when added to the children's singers' formant cluster, may be the key to cueing the notion of ring in the child solo voice. Copyright © 2014 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  11. World Record Magnetic Field 100T

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, Ross; Mielke, Chuck; Rickel, Dwight

    2012-03-22

    Scientists at the Los Alamos National Laboratory campus of the National High Magnetic Field Laboratory have successfully produced the world's first 100 Tesla non-destructive magnetic field. The achievement was decades in the making, involving a diverse team of scientists and engineers. The 100 Tesla mark was reached at approximately 3:30 p.m. on March 22, 2012. A note about the sound you'll hear when the magnet is energized: The sound that the 100 T multi-shot magnet makes is due to the electrical current modulation from the 3 phase power converters (known as 12 pulse converters) and the harmonics associated with themore » chopping of the sinusoidal input power. The magnet vibrates at the electrical current frequencies multiplied by 12 (i.e. ~ 55 Hz x 12 = 660 Hz) hence making an audible sound. The generator is not run at full speed (1650 RPM instead of 1800 RPM) so the frequency is slightly lower than US Line frequency (i.e. 55 Hz instead of 60 Hz). A spectrograph of the sound from the magnet pulse shows the multiple harmonics as reddish horizontal bands as a function of time.« less

  12. Apparatus for detecting the presence of a liquid

    DOEpatents

    Kronberg, J.W.

    1995-10-31

    An apparatus is described for detecting the presence of a liquid in a region, including an electrically passive sensor adapted for contacting the liquid, and an electrically active detector. The sensor is a circuit with a pair of spaced-apart terminals connected to a switch that closes in the presence of the liquid. The detector carries an alternating current with a resonant frequency. When the sensor is placed in a region and liquid is present in the region, the circuit of the sensor is closed. By bringing the detector close to the sensor, an alternating current is induced in the sensor that will, in turn, alter the resonant frequency of the detector. The change in the resonant frequency is signaled by a transducer. The switch can operate by a change in conductivity of a material between the terminals of the sensor or by expansion of a liquid absorber that pushes the two terminals together, or by a change in the conductivity of the space between the terminals as a result of the presence of the liquid. The detector generates an audible or visible signal, or both, in response to the change in current. 12 figs.

  13. Estimating material viscoelastic properties based on surface wave measurements: A comparison of techniques and modeling assumptions

    PubMed Central

    Royston, Thomas J.; Dai, Zoujun; Chaunsali, Rajesh; Liu, Yifei; Peng, Ying; Magin, Richard L.

    2011-01-01

    Previous studies of the first author and others have focused on low audible frequency (<1 kHz) shear and surface wave motion in and on a viscoelastic material comprised of or representative of soft biological tissue. A specific case considered has been surface (Rayleigh) wave motion caused by a circular disk located on the surface and oscillating normal to it. Different approaches to identifying the type and coefficients of a viscoelastic model of the material based on these measurements have been proposed. One approach has been to optimize coefficients in an assumed viscoelastic model type to match measurements of the frequency-dependent Rayleigh wave speed. Another approach has been to optimize coefficients in an assumed viscoelastic model type to match the complex-valued frequency response function (FRF) between the excitation location and points at known radial distances from it. In the present article, the relative merits of these approaches are explored theoretically, computationally, and experimentally. It is concluded that matching the complex-valued FRF may provide a better estimate of the viscoelastic model type and parameter values; though, as the studies herein show, there are inherent limitations to identifying viscoelastic properties based on surface wave measurements. PMID:22225067

  14. Audible Beaconing with Accessible Pedestrian Signals

    PubMed Central

    Barlow, Janet M.; Scott, Alan C.; Bentzen, Billie Louise

    2010-01-01

    Purpose Although Accessible Pedestrian Signals (APS) are often assumed to provide wayfinding information, the type of APS that has been typically installed in the U.S has not had positive effects on finding crosswalks, locating pushbuttons, or providing directional guidance. This paper reports the results of research on crossings by blind pedestrians at complex signalized intersections, before and after the installation of APS with innovative audible beaconing features, designed to improve wayfinding. Methods Objective data on measures of street crossing performance by 56 participants was obtained at four intersections, two each in Charlotte, NC, and Portland, OR. Results In the first round of testing, APS with beaconing features resulted in only slightly improved wayfinding. Revisions to the audible beaconing features resulted in improved performance on four measures of wayfinding as compared to the pre-installation condition: beginning crossings within the crosswalk, ending crossings within the crosswalk, independence in finding the starting location, and independence in aligning to cross. Implications for Practice Use of APS that provide beaconing from the far-end of the crosswalk show promise of improving wayfinding at street crossings. PMID:20622978

  15. Quantitative measuring system for combustible gas with audible tick rate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batz, J.E.

    1979-09-04

    Northern Illinois Gas Co.'s new gas-detection instrument is lightweight, portable, easy to use, and in compliance with industry standards as an intrinsically safe device. The instrument uses a semiconductor gas-sensor element energyzed with the regulated voltage source. Placed in the atmosphere to be tested, the detector generates a signal representative of the concentration of natural gas in the air. A meter displays the signal to determine whether the area is hazardous; a variable-repetition-rate blocking oscillator feeding a speaker responds to the signal, generating an audible tick rate useful in locating a leak.

  16. Instrument for analysis of electric motors based on slip-poles component

    DOEpatents

    Haynes, Howard D.; Ayers, Curtis W.; Casada, Donald A.

    1996-01-01

    A new instrument for monitoring the condition and speed of an operating electric motor from a remote location. The slip-poles component is derived from a motor current signal. The magnitude of the slip-poles component provides the basis for a motor condition monitor, while the frequency of the slip-poles component provides the basis for a motor speed monitor. The result is a simple-to-understand motor health monitor in an easy-to-use package. Straightforward indications of motor speed, motor running current, motor condition (e.g., rotor bar condition) and synthesized motor sound (audible indication of motor condition) are provided. With the device, a relatively untrained worker can diagnose electric motors in the field without requiring the presence of a trained engineer or technician.

  17. Instrument for analysis of electric motors based on slip-poles component

    DOEpatents

    Haynes, H.D.; Ayers, C.W.; Casada, D.A.

    1996-11-26

    A new instrument is described for monitoring the condition and speed of an operating electric motor from a remote location. The slip-poles component is derived from a motor current signal. The magnitude of the slip-poles component provides the basis for a motor condition monitor, while the frequency of the slip-poles component provides the basis for a motor speed monitor. The result is a simple-to-understand motor health monitor in an easy-to-use package. Straightforward indications of motor speed, motor running current, motor condition (e.g., rotor bar condition) and synthesized motor sound (audible indication of motor condition) are provided. With the device, a relatively untrained worker can diagnose electric motors in the field without requiring the presence of a trained engineer or technician. 4 figs.

  18. Wind turbines and health: a critical review of the scientific literature.

    PubMed

    McCunney, Robert J; Mundt, Kenneth A; Colby, W David; Dobie, Robert; Kaliski, Kenneth; Blais, Mark

    2014-11-01

    This review examines the literature related to health effects of wind turbines. We reviewed literature related to sound measurements near turbines, epidemiological and experimental studies, and factors associated with annoyance. (1) Infrasound sound near wind turbines does not exceed audibility thresholds. (2) Epidemiological studies have shown associations between living near wind turbines and annoyance. (3) Infrasound and low-frequency sound do not present unique health risks. (4) Annoyance seems more strongly related to individual characteristics than noise from turbines. Further areas of inquiry include enhanced noise characterization, analysis of predicted noise values contrasted with measured levels postinstallation, longitudinal assessments of health pre- and postinstallation, experimental studies in which subjects are "blinded" to the presence or absence of infrasound, and enhanced measurement techniques to evaluate annoyance.

  19. Skylab electronic technological advancements

    NASA Technical Reports Server (NTRS)

    Hornback, G. L.

    1974-01-01

    The present work describes three electronic devices designed for use in the Skylab airlock module: the teleprinter system, the quartz crystal microbalance contamination monitor (QCM), and the speaker. Design considerations, operation, characteristics, and system development are described for these systems, with accompanying diagrams, graphs, and photographs. The teleprinter is a thermal dot printer used to produce hard copy messages by electrically heating print elements in contact with heat-sensitive paper. The QCM was designed to estimate contamination buildup on optical surfaces of the earth resources experiment package. A vibrating quartz crystal is used as a microbalance relating deposited mass to shifts in the crystal's resonant frequency. Audio devices provide communication between crew members and between crew and STDN, and also provide audible alarms, via the caution and warning system, of out-of-limit-conditions.

  20. Oak Ridge Reservation Public Warning Siren System Annual Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. F. Gee

    2000-10-01

    The full operational test of the Oak Ridge Reservation (ORR) Public Warning Siren System (PWSS) was successfully conducted on September 27, 2000. The annual test is a full-scale sounding of the individual siren systems around each of the three Department of Energy (DOE) sites in Oak Ridge, Tennessee. The purpose of the annual test is to demonstrate and validate the siren systems' ability to alert personnel outdoors in the Immediate Notification Zones (INZ) (approximately two miles) around each site. The success of this test is based on two critical functions of the siren system. The first function is system operability.more » The system is considered operable if 90% of the sirens are operational. System diagnostics and direct field observations were used to validate the operability of the siren systems. Based on the diagnostic results and field observations, greater than 90% of the sirens were considered operational. The second function is system audibility. The system is considered audible if the siren could be heard in the immediate notification zones around each of the three sites. Direct field observations, along with sound level measurements, were used to validate the audibility of the siren system. Based on the direct field observations and sound level measurements, the siren system was considered audible. The combination of field observations, system diagnostic status reports, and sound level measurements provided a high level of confidence that the system met and would meet operational requirements upon demand. As part of the overall system test, the Tennessee Emergency Management Agency (TEMA) activated the Emergency Alerting System (EAS), which utilized area radio stations to make announcements regarding the test and to remind residents of what to do in the event of an actual emergency.« less

  1. Ionizing radiation detector

    DOEpatents

    Thacker, Louis H.

    1990-01-01

    An ionizing radiation detector is provided which is based on the principle of analog electronic integration of radiation sensor currents in the sub-pico to nano ampere range between fixed voltage switching thresholds with automatic voltage reversal each time the appropriate threshold is reached. The thresholds are provided by a first NAND gate Schmitt trigger which is coupled with a second NAND gate Schmitt trigger operating in an alternate switching state from the first gate to turn either a visible or audible indicating device on and off in response to the gate switching rate which is indicative of the level of radiation being sensed. The detector can be configured as a small, personal radiation dosimeter which is simple to operate and responsive over a dynamic range of at least 0.01 to 1000 R/hr.

  2. A New Test of Attention in Listening (TAIL) Predicts Auditory Performance

    PubMed Central

    Zhang, Yu-Xuan; Barry, Johanna G.; Moore, David R.; Amitay, Sygal

    2012-01-01

    Attention modulates auditory perception, but there are currently no simple tests that specifically quantify this modulation. To fill the gap, we developed a new, easy-to-use test of attention in listening (TAIL) based on reaction time. On each trial, two clearly audible tones were presented sequentially, either at the same or different ears. The frequency of the tones was also either the same or different (by at least two critical bands). When the task required same/different frequency judgments, presentation at the same ear significantly speeded responses and reduced errors. A same/different ear (location) judgment was likewise facilitated by keeping tone frequency constant. Perception was thus influenced by involuntary orienting of attention along the task-irrelevant dimension. When information in the two stimulus dimensions were congruent (same-frequency same-ear, or different-frequency different-ear), response was faster and more accurate than when they were incongruent (same-frequency different-ear, or different-frequency same-ear), suggesting the involvement of executive control to resolve conflicts. In total, the TAIL yielded five independent outcome measures: (1) baseline reaction time, indicating information processing efficiency, (2) involuntary orienting of attention to frequency and (3) location, and (4) conflict resolution for frequency and (5) location. Processing efficiency and conflict resolution accounted for up to 45% of individual variances in the low- and high-threshold variants of three psychoacoustic tasks assessing temporal and spectral processing. Involuntary orientation of attention to the irrelevant dimension did not correlate with perceptual performance on these tasks. Given that TAIL measures are unlikely to be limited by perceptual sensitivity, we suggest that the correlations reflect modulation of perceptual performance by attention. The TAIL thus has the power to identify and separate contributions of different components of attention to auditory perception. PMID:23300934

  3. Analysis of High Switching Frequency Quasi-Z-Source Photovoltaic Inverter Using Wide Bandgap Devices

    NASA Astrophysics Data System (ADS)

    Kayiranga, Thierry

    Power inverters continue to play a key role in todays electrical system more than ever. Power inverters employ power semiconductors to converter direct current (DC) into alternating current (AC). The performance of the semiconductors is based on speed and efficiency. Until recently, Silicon (Si) semiconductors had been established as mature. However, the continuous optimization and improvements in the production process of Si to meet today technology requirements have pushed Si materials to their theoretical limits. In an effort to find a suitable replacement, wide bandgap devices mainly Gallium Nitride (GaN) and Silicon Carbide (SiC), have proved to be excellent candidates offering high operation temperature, high blocking voltage and high switching frequency; of which the latter makes GaN a better candidate in high switching low voltage in Distributed Generations (DG). The single stage Quasi-Z-Source Inverter (qZSI) is also able to draw continuous and constant current from the source making ideal for PV applications in addition to allowing shoot-through states. The qZSI find best applications in medium level ranges where multiples qZS inverters can be cascaded (qZS-CMI) by combining the benefit of the qZSI, boost capabilities and continuous and constant input current, and those of the CMI, low output harmonic content and independent MPPT. When used with GaN devices operating at very high frequency, the qZS network impedance can be significantly reduced. However, the impedance network becomes asymmetric. The asymmetric impedance network (AIN-qZSI) has several advantages such as increased power density, increases system lifetime, small size volume and size making it more attractive for module integrated converter (MIC) concepts. However, there are technical challenges. With asymmetric component, resonance is introduced in the system leading to more losses and audible noise. With small inductances, new operation states become available further increasing the system complexity. This report investigates the AIN-qZSI and present solutions to aforementioned issues.

  4. Numerical study of dynamic glottis and tidal breathing on respiratory sounds in a human upper airway model

    PubMed Central

    Wang, Zhaoxuan; Talaat, Khaled; Glide-Hurst, Carri; Dong, Haibo

    2018-01-01

    Background Human snores are caused by vibrating anatomical structures in the upper airway. The glottis is a highly variable structure and a critical organ regulating inhaled flows. However, the effects of the glottis motion on airflow and breathing sound are not well understood, while static glottises have been implemented in most previous in silico studies. The objective of this study is to develop a computational acoustic model of human airways with a dynamic glottis and quantify the effects of glottis motion and tidal breathing on airflow and sound generation. Methods Large eddy simulation and FW-H models were adopted to compute airflows and respiratory sounds in an image-based mouth-lung model. User-defined functions were developed that governed the glottis kinematics. Varying breathing scenarios (static vs. dynamic glottis; constant vs. sinusoidal inhalations) were simulated to understand the effects of glottis motion and inhalation pattern on sound generation. Pressure distributions were measured in airway casts with different glottal openings for model validation purpose. Results Significant flow fluctuations were predicted in the upper airways at peak inhalation rates or during glottal constriction. The inhalation speed through the glottis was the predominating factor in the sound generation while the transient effects were less important. For all frequencies considered (20–2500 Hz), the static glottis substantially underestimated the intensity of the generated sounds, which was most pronounced in the range of 100–500 Hz. Adopting an equivalent steady flow rather than a tidal breathing further underestimated the sound intensity. An increase of 25 dB in average was observed for the life condition (sine-dynamic) compared to the idealized condition (constant-rigid) for the broadband frequencies, with the largest increase of approximately 40 dB at the frequency around 250 Hz. Conclusion Results show that a severely narrowing glottis during inhalation, as well as flow fluctuations in the downstream trachea, can generate audible sound levels. PMID:29101633

  5. Numerical study of dynamic glottis and tidal breathing on respiratory sounds in a human upper airway model.

    PubMed

    Xi, Jinxiang; Wang, Zhaoxuan; Talaat, Khaled; Glide-Hurst, Carri; Dong, Haibo

    2018-05-01

    Human snores are caused by vibrating anatomical structures in the upper airway. The glottis is a highly variable structure and a critical organ regulating inhaled flows. However, the effects of the glottis motion on airflow and breathing sound are not well understood, while static glottises have been implemented in most previous in silico studies. The objective of this study is to develop a computational acoustic model of human airways with a dynamic glottis and quantify the effects of glottis motion and tidal breathing on airflow and sound generation. Large eddy simulation and FW-H models were adopted to compute airflows and respiratory sounds in an image-based mouth-lung model. User-defined functions were developed that governed the glottis kinematics. Varying breathing scenarios (static vs. dynamic glottis; constant vs. sinusoidal inhalations) were simulated to understand the effects of glottis motion and inhalation pattern on sound generation. Pressure distributions were measured in airway casts with different glottal openings for model validation purpose. Significant flow fluctuations were predicted in the upper airways at peak inhalation rates or during glottal constriction. The inhalation speed through the glottis was the predominating factor in the sound generation while the transient effects were less important. For all frequencies considered (20-2500 Hz), the static glottis substantially underestimated the intensity of the generated sounds, which was most pronounced in the range of 100-500 Hz. Adopting an equivalent steady flow rather than a tidal breathing further underestimated the sound intensity. An increase of 25 dB in average was observed for the life condition (sine-dynamic) compared to the idealized condition (constant-rigid) for the broadband frequencies, with the largest increase of approximately 40 dB at the frequency around 250 Hz. Results show that a severely narrowing glottis during inhalation, as well as flow fluctuations in the downstream trachea, can generate audible sound levels.

  6. Magnetoencephalographic accuracy profiles for the detection of auditory pathway sources.

    PubMed

    Bauer, Martin; Trahms, Lutz; Sander, Tilmann

    2015-04-01

    The detection limits for cortical and brain stem sources associated with the auditory pathway are examined in order to analyse brain responses at the limits of the audible frequency range. The results obtained from this study are also relevant to other issues of auditory brain research. A complementary approach consisting of recordings of magnetoencephalographic (MEG) data and simulations of magnetic field distributions is presented in this work. A biomagnetic phantom consisting of a spherical volume filled with a saline solution and four current dipoles is built. The magnetic fields outside of the phantom generated by the current dipoles are then measured for a range of applied electric dipole moments with a planar multichannel SQUID magnetometer device and a helmet MEG gradiometer device. The inclusion of a magnetometer system is expected to be more sensitive to brain stem sources compared with a gradiometer system. The same electrical and geometrical configuration is simulated in a forward calculation. From both the measured and the simulated data, the dipole positions are estimated using an inverse calculation. Results are obtained for the reconstruction accuracy as a function of applied electric dipole moment and depth of the current dipole. We found that both systems can localize cortical and subcortical sources at physiological dipole strength even for brain stem sources. Further, we found that a planar magnetometer system is more suitable if the position of the brain source can be restricted in a limited region of the brain. If this is not the case, a helmet-shaped sensor system offers more accurate source estimation.

  7. Passive pavement-mounted acoustical linguistic drive alert system and method

    DOEpatents

    Kisner, Roger A.; Anderson, Richard L.; Carnal, Charles L.; Hylton, James O.; Stevens, Samuel S.

    2001-01-01

    Systems and methods are described for passive pavement-mounted acoustical alert of the occupants of a vehicle. A method of notifying a vehicle occupant includes providing a driving medium upon which a vehicle is to be driven; and texturing a portion of the driving medium such that the textured portion interacts with the vehicle to produce audible signals, the textured portion pattern such that a linguistic message is encoded into the audible signals. The systems and methods provide advantages because information can be conveyed to the occupants of the vehicle based on the location of the vehicle relative to the textured surface.

  8. System and Method for Providing a Real Time Audible Message to a Pilot

    NASA Technical Reports Server (NTRS)

    Johnson, Walter W. (Inventor); Lachter, Joel B. (Inventor); Koteskey, Robert W. (Inventor); Battiste, Vernol (Inventor)

    2016-01-01

    A system and method for providing information to a crew of the aircraft while in-flight. The system includes a module having: a receiver for receiving a message while in-flight; a filter having a set of screening parameters and operative to filter the message based on the set of screening parameters; and a converter for converting the message into an audible message. The message includes a pilot report having at least one of weather information, separation information, congestion information, flight deviation information and destination information. The message is sent to the aircraft by another aircraft or an air traffic controller.

  9. Low Voltage MEMS Digital Loudspeaker Array Based on Thin-film PZT Actuators

    NASA Astrophysics Data System (ADS)

    Fanget, S.; Casset, F.; Dejaeger, R.; Maire, F.; Desloges, B.; Deutzer, J.; Morisson, R.; Bohard, Y.; Laroche, B.; Escato, J.; Leclere, Q.

    This paper reports on the development of a Digital Loudspeaker Array (DLA) solution based on Pb(Zr0.52,Ti0.48)O3 (PZT) thin-film actuated membranes. These membranes called speaklets are arranged in a matrix and operate in a binary manner by emitting short pulses of sound pressure. Using the principle of additivity of pressures in the air, it is possible to reconstruct audible sounds. For the first time, electromechanical and acoustic characterizations are reported on a 256-MEMS-membranes DLA. Sounds audible as far as several meters from the loudspeaker have been generated using low voltage (8 V).

  10. Mechanisms of spectral and temporal integration in the mustached bat inferior colliculus

    PubMed Central

    Wenstrup, Jeffrey James; Nataraj, Kiran; Sanchez, Jason Tait

    2012-01-01

    This review describes mechanisms and circuitry underlying combination-sensitive response properties in the auditory brainstem and midbrain. Combination-sensitive neurons, performing a type of auditory spectro-temporal integration, respond to specific, properly timed combinations of spectral elements in vocal signals and other acoustic stimuli. While these neurons are known to occur in the auditory forebrain of many vertebrate species, the work described here establishes their origin in the auditory brainstem and midbrain. Focusing on the mustached bat, we review several major findings: (1) Combination-sensitive responses involve facilitatory interactions, inhibitory interactions, or both when activated by distinct spectral elements in complex sounds. (2) Combination-sensitive responses are created in distinct stages: inhibition arises mainly in lateral lemniscal nuclei of the auditory brainstem, while facilitation arises in the inferior colliculus (IC) of the midbrain. (3) Spectral integration underlying combination-sensitive responses requires a low-frequency input tuned well below a neuron's characteristic frequency (ChF). Low-ChF neurons in the auditory brainstem project to high-ChF regions in brainstem or IC to create combination sensitivity. (4) At their sites of origin, both facilitatory and inhibitory combination-sensitive interactions depend on glycinergic inputs and are eliminated by glycine receptor blockade. Surprisingly, facilitatory interactions in IC depend almost exclusively on glycinergic inputs and are largely independent of glutamatergic and GABAergic inputs. (5) The medial nucleus of the trapezoid body (MNTB), the lateral lemniscal nuclei, and the IC play critical roles in creating combination-sensitive responses. We propose that these mechanisms, based on work in the mustached bat, apply to a broad range of mammals and other vertebrates that depend on temporally sensitive integration of information across the audible spectrum. PMID:23109917

  11. Apparatus for detecting the presence of a liquid

    DOEpatents

    Kronberg, J.W.

    1993-01-01

    This invention is comprised of an apparatus for detecting the presence of a liquid in a region, including an electrically passive sensor adapted for contacting the liquid, and an electrically active detector. The sensor is a circuit with a pair of spaced-apart terminals connected to a switch that closes in the presence of the liquid. The detector carries an alternating current with a resonant frequency. When the sensor is placed in a region and liquid is present, the circuit of the sensor is closed. By bringing the detector close to the sensor, an alternating current is induced in the sensor that will, in turn, alter the resonant frequency of the detector. This change is signaled by a transducer. The switch can operate by a change in conductivity of a material between the terminals of the sensor or by expansion of a liquid absorber that pushes the two terminals together, or by a change in the conductivity of the space between the terminals as a result of the liquid. The detector generates an audible or visible signal, or both, in response to the current change.

  12. Evaluating the performance of active noise control systems in commercial and industrial applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Depies, C.; Deneen, S.; Lowe, M.

    1995-06-01

    Active sound cancellation technology is increasingly being used to quiet commercial and industrial air-moving devices. Engineers and designers are implementing active or combination active/passive technology to control sound quality in the workplace and the acoustical environment in residential areas near industrial facilities. Sound level measurements made before and after the installation of active systems have proved that significant improvements in sound quality can be obtained even if there is little or no change in the NC/RC or dBA numbers. Noise produced by centrifugal and vane-axial fans, pumps and blowers, commonly used for ventilation and material movement in industry, are frequentlymore » dominated by high amplitude, tonal noise at low frequencies. And the low-frequency noise produced by commercial air handlers often has less tonal and more broadband characteristics, resulting in audible duct rumble noise and objectionable room spectrums. Because the A-weighting network, which is commonly used for industrial noise measurements, de-emphasizes low frequencies, its single number rating can be misleading in terms of judging the overall subjective sound quality in impacted areas and assessing the effectiveness of noise control measures. Similarly, NC values, traditionally used for commercial HVAC acoustical design criteria, can be governed by noise at any frequency and cannot accurately depict human judgment of the aural comfort level. Analyses of frequency spectrum characteristics provide the most effective means of assessing sound quality and determining mitigative measures for achieving suitable background sound levels.« less

  13. Air pressure waves from Mount St. Helens eruptions

    NASA Astrophysics Data System (ADS)

    Reed, Jack W.

    1987-10-01

    Infrasonic recordings of the pressure wave from the Mount St. Helens (MSH) eruption on May 18, 1980, together with the weather station barograph records were used to estimate an equivalent explosion airblast yield for this eruption. Pressure wave amplitudes versus distance patterns were found to be comparable with patterns found for a small-scale nuclear explosion, the Krakatoa eruption, and the Tunguska comet impact, indicating that the MSH wave came from an explosion equivalent of about 5 megatons of TNT. The peculiar audibility pattern reported, with the blast being heard only at ranges beyond about 100 km, is explained by consideration of finite-amplitude shock propagation developments.

  14. A Subjective Test of Modulated Blade Spacing for Helicopter Main Rotors

    NASA Technical Reports Server (NTRS)

    Sullivan, Brenda M.; Edwards, Bryan D.; Brentner, Kenneth S.; Booth, Earl R., Jr.

    2002-01-01

    Analytically, uneven (modulated) spacing of main rotor blades was found to reduce helicopter noise. A study was performed to see if these reductions transferred to improvements in subjective response. Using a predictive computer code, sounds produced by six main rotor configurations: 4 blades evenly spaced, 5 blades evenly spaced and four configurations with 5 blades with modulated spacing of varying amounts, were predicted. These predictions were converted to audible sounds corresponding to the level flyover, takeoff and approach flight conditions. Subjects who heard the simulations were asked to assess the overflight sounds in terms of noisiness on a scale of 0 to 10. In general the evenly spaced configurations were found less noisy than the modulated spacings, possibly because the uneven spacings produced a perceptible pulsating sound due to the very low fundamental frequency.

  15. Psychoacoustic Analysis of Synthesized Jet Noise

    NASA Technical Reports Server (NTRS)

    Okcu, Selen; Rathsam, Jonathan; Rizzi, Stephen A.

    2013-01-01

    An aircraft noise synthesis capability is being developed so the annoyance caused by proposed aircraft can be assessed during the design stage. To make synthesized signals as realistic as possible, high fidelity simulation is required for source (e.g., engine noise, airframe noise), propagation and receiver effects. This psychoacoustic study tests whether the jet noise component of synthesized aircraft engine noise can be made more realistic using a low frequency oscillator (LFO) technique to simulate fluctuations in level observed in recordings. Jet noise predictions are commonly made in the frequency domain based on models of time-averaged empirical data. The synthesis process involves conversion of the frequency domain prediction into an audible pressure time history. However, because the predictions are time-invariant, the synthesized sound lacks fluctuations observed in recordings. Such fluctuations are hypothesized to be perceptually important. To introduce time-varying characteristics into jet noise synthesis, a method has been developed that modulates measured or predicted 1/3-octave band levels with a (<20Hz) LFO. The LFO characteristics are determined through analysis of laboratory jet noise recordings. For the aft emission angle, results indicate that signals synthesized using a generic LFO are perceived as more similar to recordings than those using no LFO, and signals synthesized with an angle-specific LFO are more similar to recordings than those synthesized with a generic LFO.

  16. Piezohydraulic Pump Development

    NASA Technical Reports Server (NTRS)

    Lynch, Christopher S.

    2005-01-01

    Reciprocating piston piezohydraulic pumps were developed originally under the Smart Wing Phase II program (Lynch) and later under the CHAP program (CSA, Kinetic Ceramics). These pumps focused on 10 cm scale stack actuators operating below resonance and, more recently, at resonance. A survey of commercially available linear actuators indicates that obtaining power density and specific power greater than electromagnetic linear actuators requires driving the stacks at frequencies greater than 1 KHz at high fields. In the case of 10 cm scale actuators the power supply signal conditioning becomes large and heavy and the soft PZT stack actuators generate a lot of heat due to internal losses. Reciprocation frequencies can be increased and material losses significantly decreased through use of millimeter scale single crystal stack actuators. We are presently targeting the design of pumps that utilize stacks at the 1-10 mm length scale and run at reciprocating frequencies of 20kHz or greater. This offers significant advantages over current approaches including eliminating audible noise and significantly increasing the power density and specific power of the system (including electronics). The pump currently under development will comprise an LC resonant drive of a resonant crystal and head mass operating against a resonant fluid column. Each of these resonant systems are high Q and together should produce a single high Q second order system.

  17. Evaluating standard airborne sound insulation measures in terms of annoyance, loudness, and audibility ratings.

    PubMed

    Park, H K; Bradley, J S

    2009-07-01

    This paper reports the results of an evaluation of the merits of standard airborne sound insulation measures with respect to subjective ratings of the annoyance and loudness of transmitted sounds. Subjects listened to speech and music sounds modified to represent transmission through 20 different walls with sound transmission class (STC) ratings from 34 to 58. A number of variations in the standard measures were also considered. These included variations in the 8-dB rule for the maximum allowed deficiency in the STC measure as well as variations in the standard 32-dB total allowed deficiency. Several spectrum adaptation terms were considered in combination with weighted sound reduction index (R(w)) values as well as modifications to the range of included frequencies in the standard rating contour. A STC measure without an 8-dB rule and an R(w) rating with a new spectrum adaptation term were better predictors of annoyance and loudness ratings of speech sounds. R(w) ratings with one of two modified C(tr) spectrum adaptation terms were better predictors of annoyance and loudness ratings of transmitted music sounds. Although some measures were much better predictors of responses to one type of sound than were the standard STC and R(w) values, no measure was remarkably improved for predicting annoyance and loudness ratings of both music and speech sounds.

  18. Acoustic Imaging of Snowpack Physical Properties

    NASA Astrophysics Data System (ADS)

    Kinar, N. J.; Pomeroy, J. W.

    2011-12-01

    Measurements of snowpack depth, density, structure and temperature have often been conducted by the use of snowpits and invasive measurement devices. Previous research has shown that acoustic waves passing through snow are capable of measuring these properties. An experimental observation device (SAS2, System for the Acoustic Sounding of Snow) was used to autonomously send audible sound waves into the top of the snowpack and to receive and process the waves reflected from the interior and bottom of the snowpack. A loudspeaker and microphone array separated by an offset distance was suspended in the air above the surface of the snowpack. Sound waves produced from a loudspeaker as frequency-swept sequences and maximum length sequences were used as source signals. Up to 24 microphones measured the audible signal from the snowpack. The signal-to-noise ratio was compared between sequences in the presence of environmental noise contributed by wind and reflections from vegetation. Beamforming algorithms were used to reject spurious reflections and to compensate for movement of the sensor assembly during the time of data collection. A custom-designed circuit with digital signal processing hardware implemented an inversion algorithm to relate the reflected sound wave data to snowpack physical properties and to create a two-dimensional image of snowpack stratigraphy. The low power consumption circuit was powered by batteries and through WiFi and Bluetooth interfaces enabled the display of processed data on a mobile device. Acoustic observations were logged to an SD card after each measurement. The SAS2 system was deployed at remote field locations in the Rocky Mountains of Alberta, Canada. Acoustic snow properties data was compared with data collected from gravimetric sampling, thermocouple arrays, radiometers and snowpit observations of density, stratigraphy and crystal structure. Aspects for further research and limitations of the acoustic sensing system are also discussed.

  19. Worker piping triggers hissing for coordinated colony defence in the dwarf honeybee Apis florea.

    PubMed

    Sen Sarma, Moushumi; Fuchs, Stefan; Werber, Christian; Tautz, Jürgen

    2002-01-01

    Defending a large social insect colony containing several thousands of workers requires the simultaneous action of many individuals. Ideally this action involves communication between the workers, enabling coordinated action and a fast response. The Asian dwarf honeybee, Apis florea, is a small honeybee with an open nesting habit and a comparatively small colony size, features that leave them particularly exposed to predators. We describe here a novel defence response of these bees in which the emission of an initial warning signal from one individual ("piping") is followed 0.3 to 0.7 seconds later by a general response from a large number of bees ("hissing"). Piping is audible to the human ear, with a fundamental frequency of 384 +/- 31Hz and lasting for 0.82 +/- 0.35 seconds. Hissing is a broad band, noisy signal, clearly audible to the human observer and produced by slight but visible movements of the bees' wings. Hissing begins in individuals close to the piping bee, spreads rapidly to neighbours and results in an impressive coordinated crescendo occasionally involving the entire colony. Piping and hissing are accompanied by a marked decrease, or even cessation, of worker activities such as forager dancing and departures from the colony. We show that whereas hissing of the colony can be elicited without piping, the sequential and correlated piping and hissing response is specific to the presence of potential predators close to the colony. We suggest that the combined audio-visual effect of the hissing might deter small predators, while the cessation of flight activity could decrease the risk of predation by birds and insects which prey selectively on flying bees.

  20. Modulation frequency discrimination with single and multiple channels in cochlear implant users

    PubMed Central

    Galvin, John J.; Oba, Sandy; Başkent, Deniz; Fu, Qian-Jie

    2015-01-01

    Temporal envelope cues convey important speech information for cochlear implant (CI) users. Many studies have explored CI users’ single-channel temporal envelope processing. However, in clinical CI speech processors, temporal envelope information is processed by multiple channels. Previous studies have shown that amplitude modulation frequency discrimination (AMFD) thresholds are better when temporal envelopes are delivered to multiple rather than single channels. In clinical fitting, current levels on single channels must often be reduced to accommodate multi-channel loudness summation. As such, it is unclear whether the multi-channel advantage in AMFD observed in previous studies was due to coherent envelope information distributed across the cochlea or to greater loudness associated with multi-channel stimulation. In this study, single- and multi-channel AMFD thresholds were measured in CI users. Multi-channel component electrodes were either widely or narrowly spaced to vary the degree of overlap between neural populations. The reference amplitude modulation (AM) frequency was 100 Hz, and coherent modulation was applied to all channels. In Experiment 1, single- and multi-channel AMFD thresholds were measured at similar loudness. In this case, current levels on component channels were higher for single- than for multi-channel AM stimuli, and the modulation depth was approximately 100% of the perceptual dynamic range (i.e., between threshold and maximum acceptable loudness). Results showed no significant difference in AMFD thresholds between similarly loud single- and multi-channel modulated stimuli. In Experiment 2, single- and multi-channel AMFD thresholds were compared at substantially different loudness. In this case, current levels on component channels were the same for single-and multi-channel stimuli (“summation-adjusted” current levels) and the same range of modulation (in dB) was applied to the component channels for both single- and multi-channel testing. With the summation-adjusted current levels, loudness was lower with single than with multiple channels and the AM depth resulted in substantial stimulation below single-channel audibility, thereby reducing the perceptual range of AM. Results showed that AMFD thresholds were significantly better with multiple channels than with any of the single component channels. There was no significant effect of the distribution of electrodes on multi-channel AMFD thresholds. The results suggest that increased loudness due to multi-channel summation may contribute to the multi-channel advantage in AMFD, and that that overall loudness may matter more than the distribution of envelope information in the cochlea. PMID:25746914

  1. Testing the concept of a modulation filter bank: the audibility of component modulation and detection of phase change in three-component modulators.

    PubMed

    Sek, Aleksander; Moore, Brian C J

    2003-05-01

    Two experiments were performed to test the concept that the auditory system contains a "modulation filter bank" (MFB). Experiment 1 examined the ability to "hear out" the modulation frequency of the central component of a three-component modulator applied to a 4-kHz sinusoidal carrier. On each trial, three modulated stimuli were presented. The modulator of the first stimulus contained three components. Within a run the frequencies of the outer two components were fixed and the frequency of the central ("target") component was drawn randomly from one of five values. The modulators of second and third stimuli contained one component. One had a frequency equal to that of the target and the other had a frequency randomly selected from one of the other possible values. Subjects indicated whether the target corresponded to the second or third stimulus. Scores were around 80% correct when the components in the three-component modulator were widely spaced and when the frequencies of the target and comparison differed sufficiently. Experiment 2 examined the ability to hear a change in the relative phase of the components in a three-component modulator with harmonically spaced components, using a 31FC task. The frequency of the central component, f(c), was either 50 or 100 Hz. Scores were 80%-90% correct when the component spacing was < or = 0.5 f(c), but decreased markedly for greater spacings. Performance was only slightly impaired by randomizing the overall modulation depth from one stimulus to the next. The results of both experiments are broadly consistent with what would be expected from a MFB with a Q value of 1 or slightly less.

  2. Measures for assessing architectural speech security (privacy) of closed offices and meeting rooms.

    PubMed

    Gover, Bradford N; Bradley, John S

    2004-12-01

    Objective measures were investigated as predictors of the speech security of closed offices and rooms. A new signal-to-noise type measure is shown to be a superior indicator for security than existing measures such as the Articulation Index, the Speech Intelligibility Index, the ratio of the loudness of speech to that of noise, and the A-weighted level difference of speech and noise. This new measure is a weighted sum of clipped one-third-octave-band signal-to-noise ratios; various weightings and clipping levels are explored. Listening tests had 19 subjects rate the audibility and intelligibility of 500 English sentences, filtered to simulate transmission through various wall constructions, and presented along with background noise. The results of the tests indicate that the new measure is highly correlated with sentence intelligibility scores and also with three security thresholds: the threshold of intelligibility (below which speech is unintelligible), the threshold of cadence (below which the cadence of speech is inaudible), and the threshold of audibility (below which speech is inaudible). The ratio of the loudness of speech to that of noise, and simple A-weighted level differences are both shown to be well correlated with these latter two thresholds (cadence and audibility), but not well correlated with intelligibility.

  3. Longitudinal changes in speech recognition in older persons.

    PubMed

    Dubno, Judy R; Lee, Fu-Shing; Matthews, Lois J; Ahlstrom, Jayne B; Horwitz, Amy R; Mills, John H

    2008-01-01

    Recognition of isolated monosyllabic words in quiet and recognition of key words in low- and high-context sentences in babble were measured in a large sample of older persons enrolled in a longitudinal study of age-related hearing loss. Repeated measures were obtained yearly or every 2 to 3 years. To control for concurrent changes in pure-tone thresholds and speech levels, speech-recognition scores were adjusted using an importance-weighted speech-audibility metric (AI). Linear-regression slope estimated the rate of change in adjusted speech-recognition scores. Recognition of words in quiet declined significantly faster with age than predicted by declines in speech audibility. As subjects aged, observed scores deviated increasingly from AI-predicted scores, but this effect did not accelerate with age. Rate of decline in word recognition was significantly faster for females than males and for females with high serum progesterone levels, whereas noise history had no effect. Rate of decline did not accelerate with age but increased with degree of hearing loss, suggesting that with more severe injury to the auditory system, impairments to auditory function other than reduced audibility resulted in faster declines in word recognition as subjects aged. Recognition of key words in low- and high-context sentences in babble did not decline significantly with age.

  4. Changes in the highest frequency of breath sounds without wheezing during methacholine inhalation challenge in children.

    PubMed

    Habukawa, Chizu; Murakami, Katsumi; Mochizuki, Hiroyuki; Takami, Satoru; Muramatsu, Reiko; Tadaki, Hiromi; Hagiwara, Satomi; Mizuno, Takahisa; Arakawa, Hirokazu; Nagasaka, Yukio

    2010-04-01

    It is difficult for clinicians to identify changes in breath sounds caused by bronchoconstriction when wheezing is not audible. A breath sound analyser can identify changes in the frequency of breath sounds caused by bronchoconstriction. The present study aimed to identify the changes in the frequency of breath sounds during bronchoconstriction and bronchodilatation using a breath sound analyser. Thirty-six children (8.2 +/- 3.7 years; males : females, 22 : 14) underwent spirometry, methacholine inhalation challenge and breath sound analysis. Methacholine inhalation challenge was performed and baseline respiratory resistance, minimum dose of methacholine (bronchial sensitivity) and speed of bronchoconstriction in response to methacholine (Sm: bronchial reactivity) were calculated. The highest frequency of inspiratory breath sounds (HFI), the highest frequency of expiratory breath sounds (HFE) and the percentage change in HFI and HFE were determined. The HFI and HFE were compared before methacholine inhalation (pre-HFI and pre-HFE), when respiratory resistance reached double the baseline value (max HFI and max HFE), and after bronchodilator inhalation (post-HFI and post-HFE). Breath sounds increased during methacholine-induced bronchoconstriction. Max HFI was significantly greater than pre-HFI (P < 0.001), and decreased to the basal level after bronchodilator inhalation. Post-HFI was significantly lower than max HFI (P < 0.001). HFI and HFE were also significantly changed (P < 0.001). The percentage change in HFI showed a significant correlation with the speed of bronchoconstriction in response to methacholine (P = 0.007). Methacholine-induced bronchoconstriction significantly increased HFI, and the increase in HFI was correlated with bronchial reactivity.

  5. Implant for in-vivo parameter monitoring, processing and transmitting

    DOEpatents

    Ericson, Milton N [Knoxville, TN; McKnight, Timothy E [Greenback, TN; Smith, Stephen F [London, TN; Hylton, James O [Clinton, TN

    2009-11-24

    The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.

  6. Implantable device for in-vivo intracranial and cerebrospinal fluid pressure monitoring

    DOEpatents

    Ericson, Milton N.; McKnight, Timothy E.; Smith, Stephen F.; Hylton, James O.

    2003-01-01

    The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.

  7. An inexpensive frequency-modulated (FM) audio monitor of time-dependent analog parameters.

    PubMed

    Langdon, R B; Jacobs, R S

    1980-02-01

    The standard method for quantification and presentation of an experimental variable in real time is the use of visual display on the ordinate of an oscilloscope screen or chart recorder. This paper describes a relatively simple electronic circuit, using commercially available and inexpensive integrated circuits (IC), which generates an audible tone, the pitch of which varies in proportion to a running variable of interest. This device, which we call an "Audioscope," can accept as input the monitor output from any instrument that expresses an experimental parameter as a dc voltage. The Audioscope is particularly useful in implanting microelectrodes intracellularly. It may also function to mediate the first step in data recording on magnetic tape, and/or data analysis and reduction by electronic circuitary. We estimate that this device can be built, with two-channel capability, for less than $50, and in less than 10 hr by an experienced electronics technician.

  8. Exposure to seismic survey alters blue whale acoustic communication

    PubMed Central

    Di Iorio, Lucia; Clark, Christopher W.

    2010-01-01

    The ability to perceive biologically important sounds is critical to marine mammals, and acoustic disturbance through human-generated noise can interfere with their natural functions. Sounds from seismic surveys are intense and have peak frequency bands overlapping those used by baleen whales, but evidence of interference with baleen whale acoustic communication is sparse. Here we investigated whether blue whales (Balaenoptera musculus) changed their vocal behaviour during a seismic survey that deployed a low-medium power technology (sparker). We found that blue whales called consistently more on seismic exploration days than on non-exploration days as well as during periods within a seismic survey day when the sparker was operating. This increase was observed for the discrete, audible calls that are emitted during social encounters and feeding. This response presumably represents a compensatory behaviour to the elevated ambient noise from seismic survey operations. PMID:19776059

  9. Foreign bodies in the larynx and tracheobronchial tree in children. A review of 225 cases.

    PubMed

    Rothmann, B F; Boeckman, C R

    1980-01-01

    In a study of 225 patients with foreign bodies in the larynx, trachea and bronchi, 77% were 36 months of age or less. The male-female ratio was 2:1. Food or food derivatives were the causative agent in 70% of the cases, with 38% due to a portion of nut. The foreign body involved the right and left bronchus with equal frequency. A choking episode followed by an audible wheeze (55%) was the most common presenting complaint. Obstructive emphysema was demonstrated in 60% and was best demonstrated by inspiration-expiration chest roentgenograms or fluoroscopy. A radio-opaque object was seen in 13%. Two hundred ten foreign objects (93%) were removed by endoscopy. Four patients required pulmonary resection for bronchiectasis and in three patients bronchotomy was performed. Five patients expelled the foreign body spontaneously, two patients were transferred to another hospital, and one foreign body was not recovered. There was no mortality.

  10. Light-induced vibration in the hearing organ

    PubMed Central

    Ren, Tianying; He, Wenxuan; Li, Yizeng; Grosh, Karl; Fridberger, Anders

    2014-01-01

    The exceptional sensitivity of mammalian hearing organs is attributed to an active process, where force produced by sensory cells boost sound-induced vibrations, making soft sounds audible. This process is thought to be local, with each section of the hearing organ capable of amplifying sound-evoked movement, and nearly instantaneous, since amplification can work for sounds at frequencies up to 100 kHz in some species. To test these fundamental precepts, we developed a method for focally stimulating the living hearing organ with light. Light pulses caused intense and highly damped mechanical responses followed by traveling waves that developed with considerable delay. The delayed response was identical to movements evoked by click-like sounds. This shows that the active process is neither local nor instantaneous, but requires mechanical waves traveling from the cochlear base toward its apex. A physiologically-based mathematical model shows that such waves engage the active process, enhancing hearing sensitivity. PMID:25087606

  11. Resonant Interaction of a Rectangular Jet with a Flat-Plate

    NASA Technical Reports Server (NTRS)

    Zaman, K. B. M. Q.; Fagan, A. F.; Clem, M. M.; Brown, C. A.

    2014-01-01

    A resonant interaction between a large aspect ratio rectangular jet and a flat-plate is addressed in this experimental study. The plate is placed parallel to but away from the direct path of the jet. At high subsonic conditions and for certain relative locations of the plate, the resonance accompanied by an audible tone is encountered. The trends of the tone frequency variation exhibit some similarities to, but also marked differences from, corresponding trends of the well-known edge-tone phenomenon. Under the resonant condition flow visualization indicates a periodic flapping motion of the jet column. Phase-averaged Mach number data obtained near the plate's trailing edge illustrate that the jet cross-section goes through large contortions within the period of the tone. Farther downstream a clear 'axis switching' takes place. These results suggest that the assumption of two-dimensionality should be viewed with caution in any analysis of the flow.

  12. Physiologic and pathologic belching.

    PubMed

    Bredenoord, Albert J; Smout, André J P M

    2007-07-01

    Accumulation of air in the stomach increases gastric volume, which activates receptors in the gastric wall. A reflex is initiated, leading to relaxation of the lower esophageal sphincter, upward movement of the air through the esophagus, and finally passage through the upper esophageal sphincter, during which an audible belch can sometimes be heard. Excessive belching is often reported in patients with gastroesophageal reflux disease and functional dyspepsia. Often other symptoms are predominant, and these should be treated first. Sometimes patients present with excessive belching as an isolated symptom. These patients belch in very high frequencies, up to 20 times per minute, and often during consultation. This condition is referred to as aerophagia. In these patients air is sucked into the esophagus or injected by pharyngeal contraction, after which it is expelled immediately. Aerophagia is a behavioral disorder, and behavioral therapy and/or speech therapy seems to be the therapy of choice.

  13. Self-demodulation of amplitude-modulated signal components in amplitude-modulated bone-conducted ultrasonic hearing

    NASA Astrophysics Data System (ADS)

    Ito, Kazuhito; Nakagawa, Seiji

    2015-07-01

    A novel hearing aid system utilizing amplitude-modulated bone-conducted ultrasound (AM-BCU) is being developed for use by profoundly deaf people. However, there is a lack of research on the acoustic aspects of AM-BCU hearing. In this study, acoustic fields in the ear canal under AM-BCU stimulation were examined with respect to the self-demodulation effect of amplitude-modulated signal components generated in the ear canal. We found self-demodulated signals with an audible sound pressure level related to the amplitude-modulated signal components of bone-conducted ultrasonic stimulation. In addition, the increases in the self-demodulated signal levels at low frequencies in the ear canal after occluding the ear canal opening, i.e., the positive occlusion effect, indicate the existence of a pathway by which the self-demodulated signals pass through the aural cartilage and soft tissue, and radiate into the ear canal.

  14. Source localization of turboshaft engine broadband noise using a three-sensor coherence method

    NASA Astrophysics Data System (ADS)

    Blacodon, Daniel; Lewy, Serge

    2015-03-01

    Turboshaft engines can become the main source of helicopter noise at takeoff. Inlet radiation mainly comes from the compressor tones, but aft radiation is more intricate: turbine tones usually are above the audible frequency range and do not contribute to the weighted sound levels; jet is secondary and radiates low noise levels. A broadband component is the most annoying but its sources are not well known (it is called internal or core noise). Present study was made in the framework of the European project TEENI (Turboshaft Engine Exhaust Noise Identification). Its main objective was to localize the broadband sources in order to better reduce them. Several diagnostic techniques were implemented by the various TEENI partners. As regards ONERA, a first attempt at separating sources was made in the past with Turbomeca using a three-signal coherence method (TSM) to reject background non-acoustic noise. The main difficulty when using TSM is the assessment of the frequency range where the results are valid. This drawback has been circumvented in the TSM implemented in TEENI. Measurements were made on a highly instrumented Ardiden turboshaft engine in the Turbomeca open-air test bench. Two engine powers (approach and takeoff) were selected to apply TSM. Two internal pressure probes were located in various cross-sections, either behind the combustion chamber (CC), the high-pressure turbine (HPT), the free-turbine first stage (TL), or in four nozzle sections. The third transducer was a far-field microphone located around the maximum of radiation, at 120° from the intake centerline. The key result is that coherence increases from CC to HPT and TL, then decreases in the nozzle up to the exit. Pressure fluctuations from HPT and TL are very coherent with the far-field acoustic spectra up to 700 Hz. They are thus the main acoustic source and can be attributed to indirect combustion noise (accuracy decreases above 700 Hz because coherence is lower, but far-field sound spectra also are much lower above 700 Hz).

  15. How do rats respond to playing radio in the animal facility?

    PubMed

    Krohn, Thomas C; Salling, Bo; Hansen, Axel Kornerup

    2011-07-01

    In the animal facility, a range of different sounds are present. On the one hand, rats and humans will regard sound and noise differently even within the audible range, but on the other hand mice and rats being very adaptable to the environment may adapt to living in a noisy facility with e.g. a radio playing. It was the aim of the present study to investigate whether two different strains of rats had different preferences for different kinds of sound patterns, including radio, and to get an indication of whether they are able to distinguish between different sound patterns. The present preference study revealed that rats were able to distinguish between different sound patterns. They showed a clear preference for silence to anything else, which may be taken as an indication that they feel disturbed by the sound from the speaker.

  16. Eddy current inspection tool. [Patent application

    DOEpatents

    Petrini, R.R.; Van Lue, D.F.

    1980-10-29

    A miniaturized inspection tool, for testing and inspection of metal objects in locations with difficult accessibility, which comprises eddy current sensing equipment with a probe coil, and associated coaxial coil cable, oil energizing means, and circuit means responsive to impedance changes in the coil as effected by induced eddy currents in a test object to produce a data output signal proportional to such changes. The coil and cable are slideably received in the utility channel of the flexible insertion tube of a fiberoptic scope. The scope is provided with light transmitting and receiving fiberoptics for viewing through the flexible tube, and articulation means for articulating the distal end of the tube and permitting close control of coil placement relative to a test object. The eddy current sensing equipment includes a tone generator for generating audible signals responsive to the data output signal. In one selected mode of operation, the tone generator responsive to the output signal above a selected level generates a constant single frequency tone for signalling detection of a discontinuity and, in a second selected mode, generates a tone whose frequency is proportional to the difference between the output signal and a predetermined selected threshold level.

  17. Measurement and Prediction of Field Transmission Loss as a Diagnostic Tool in Evaluation of Emergency Evacuation Signal Propagation in a Dormitory Facility

    NASA Astrophysics Data System (ADS)

    Robinson, Donald Arthur

    1984-06-01

    A method is presented to predict airborne and barrier transmission loss of an audible signal as it travels from a corridor based octave band sound source to a room based receiver location. Flanking pathways are not considered in the prediction model. Although the central focus of the research is on the propagation of the signal, a comprehensive review of the source, path and receiver are presented as related to emergency audible signal propagation. Linear attenuation of the signal and end wall reflection is applied along the corridor path incorporating research conducted by T. L. Redmore of Essex, England. Classical room acoustics are applied to establish the onset of linear attenuation beyond the near field. The "coincidence effect" is applied to the transmission loss through the room door barrier. A constant barrier door transmission loss from corridor-to-room is applied throughout the 250 - 8000 Hertz octave bands. In situ measurements were conducted in two separate dormitories on the University of Massachusetts Amherst campus to verify the validity of the approach. All of the experimental data points follow the corresponding points predicted by the model with all correlations exceeding 0.9. The 95 percent confidence intervals for the absolute difference between predicted and measured values ranged from 0.76 dB to 4.5 dB based on five Leq dB levels taken at each octave band along the length of the corridor. For the corridor to room attenuation in the six test rooms, with the door closed and edge sealed, the predicted minus measured levels ranged from an interval of 0.54 to 2.90 dB Leq at octave bands from 250 to 8000 Hertz. Given the inherent difficulty of in situ tests compared to laboratory or modeling approaches the confidence intervals obtained confirm the usefulness of the prediction model presented.

  18. Infrasonic tremor wavefield of the Pu`u `Ō`ō crater complex and lava tube system, Hawaii, in April 2007

    NASA Astrophysics Data System (ADS)

    Matoza, Robin S.; Fee, David; GarcéS, Milton A.

    2010-12-01

    Long-lived effusive volcanism at the Pu`u `Ō`ō crater complex, Kilauea Volcano, Hawaii produces persistent infrasonic tremor that has been recorded almost continuously for months to years. Previous studies showed that this infrasonic tremor wavefield can be recorded at a range of >10 km. However, the low signal power of this tremor relative to ambient noise levels results in significant propagation effects on signal detectability at this range. In April 2007, we supplemented a broadband infrasound array at ˜12.5 km from Pu`u `Ō`ō (MENE) with a similar array at ˜2.4 km from the source (KIPU). The additional closer-range data enable further evaluation of tropospheric propagation effects and provide higher signal-to-noise ratios for studying volcanic source processes. The infrasonic tremor source appears to consist of at least two separate physical processes. We suggest that bubble cloud oscillation in a roiling magma conduit beneath the crater complex may produce a broadband component of the tremor. Low-frequency sound sourced in a shallow magma conduit may radiate infrasound efficiently into the atmosphere due to the anomalous transparency of the magma-air interface. We further propose that more sharply peaked tones with complex temporal evolution may result from oscillatory interactions of a low-velocity gas jet with solid vent boundaries in a process analogous to the hole tone or whistler nozzle. The infrasonic tremor arrives with a median azimuth of ˜67° at KIPU. Additional infrasonic signals and audible sounds originating from the extended lava tube system to the south of the crater complex (median azimuth ˜77°) coincided with turbulent degassing activity at a new lava tube skylight. Our observations indicate that acoustic studies may aid in understanding persistent continuous degassing and unsteady flow dynamics at Kilauea Volcano.

  19. Relation between Working Memory Capacity and Auditory Stream Segregation in Children with Auditory Processing Disorder.

    PubMed

    Lotfi, Yones; Mehrkian, Saiedeh; Moossavi, Abdollah; Zadeh, Soghrat Faghih; Sadjedi, Hamed

    2016-03-01

    This study assessed the relationship between working memory capacity and auditory stream segregation by using the concurrent minimum audible angle in children with a diagnosed auditory processing disorder (APD). The participants in this cross-sectional, comparative study were 20 typically developing children and 15 children with a diagnosed APD (age, 9-11 years) according to the subtests of multiple-processing auditory assessment. Auditory stream segregation was investigated using the concurrent minimum audible angle. Working memory capacity was evaluated using the non-word repetition and forward and backward digit span tasks. Nonparametric statistics were utilized to compare the between-group differences. The Pearson correlation was employed to measure the degree of association between working memory capacity and the localization tests between the 2 groups. The group with APD had significantly lower scores than did the typically developing subjects in auditory stream segregation and working memory capacity. There were significant negative correlations between working memory capacity and the concurrent minimum audible angle in the most frontal reference location (0° azimuth) and lower negative correlations in the most lateral reference location (60° azimuth) in the children with APD. The study revealed a relationship between working memory capacity and auditory stream segregation in children with APD. The research suggests that lower working memory capacity in children with APD may be the possible cause of the inability to segregate and group incoming information.

  20. Cortical Auditory Evoked Potentials in (Un)aided Normal-Hearing and Hearing-Impaired Adults

    PubMed Central

    Van Dun, Bram; Kania, Anna; Dillon, Harvey

    2016-01-01

    Cortical auditory evoked potentials (CAEPs) are influenced by the characteristics of the stimulus, including level and hearing aid gain. Previous studies have measured CAEPs aided and unaided in individuals with normal hearing. There is a significant difference between providing amplification to a person with normal hearing and a person with hearing loss. This study investigated this difference and the effects of stimulus signal-to-noise ratio (SNR) and audibility on the CAEP amplitude in a population with hearing loss. Twelve normal-hearing participants and 12 participants with a hearing loss participated in this study. Three speech sounds—/m/, /g/, and /t/—were presented in the free field. Unaided stimuli were presented at 55, 65, and 75 dB sound pressure level (SPL) and aided stimuli at 55 dB SPL with three different gains in steps of 10 dB. CAEPs were recorded and their amplitudes analyzed. Stimulus SNRs and audibility were determined. No significant effect of stimulus level or hearing aid gain was found in normal hearers. Conversely, a significant effect was found in hearing-impaired individuals. Audibility of the signal, which in some cases is determined by the signal level relative to threshold and in other cases by the SNR, is the dominant factor explaining changes in CAEP amplitude. CAEPs can potentially be used to assess the effects of hearing aid gain in hearing-impaired users. PMID:27587919

  1. New orientation and accessibility option for persons with visual impairment: transportation applications for remote infrared audible signage.

    PubMed

    Crandall, William; Bentzen, Billie Louise; Myers, Linda; Brabyn, John

    2001-05-01

    BACKGROUND: For a blind or visually impaired person, a vital prerequisite to accessing any feature of the built environment is being able to find this feature. Braille signs, even where available, do not replace the functions of print signage because they cannot be read from a distance. Remotely readable infrared signs utilise spoken infrared message transmissions to label key environmental features, so that a blind person with a suitable receiver can locate and identify them from a distance. METHODS: Three problems that are among the most challenging and dangerous faced by blind travellers are negotiating complex transit stations, locating bus stops and safely and efficiently crossing light-controlled intersections. We report the results of human factors studies using a remote infrared audible sign system (RIAS), Talking Signs(R), in these critical tasks, examining issues such as the amount of training needed to use the system, its impact on performance and safety, benefits for different population subgroups and user opinions of its value. RESULTS: Results are presented in the form of both objective performance measures and in subjects' ratings of the usefulness of the system in performing these tasks. Findings are that blind people can quickly and easily learn to use remote infrared audible signage effectively and that its use improves travel safety, efficiency and independence.? CONCLUSIONS: The technology provides equal access to a wide variety of public facilities.

  2. Longitudinal Development of Phonology and Morphology in Children with Late-Identified Mild-Moderate Sensorineural Hearing Loss

    PubMed Central

    Moeller, Mary Pat; McCleary, Elizabeth; Putman, Coille; Tyler-Krings, Amy; Hoover, Brenda; Stelmachowicz, Patricia

    2010-01-01

    Objective Studies of language development in children with mild-moderate hearing loss are relatively rare. Longitudinal studies of children with late-identified hearing loss have not been conducted, and they are relevant for determining how a period of unaided mild-moderate hearing loss impacts development. In recent years, newborn hearing screening programs have effectively reduced the ages of identification for most children with permanent hearing loss. However, some children continue to be identified late and research is needed to guide management decisions. Further, studies of this group may help to discern if language normalizes following intervention, and/or if certain aspects of language might be vulnerable to persistent delays. The current study examines the impact of late identification and reduced audibility on speech and language outcomes via a longitudinal study of four children with mild-moderate sensorineural hearing loss. Design Longitudinal outcomes of four children with late-identified mild-moderate sensorinueral hearing loss were studied using standardized measures and language sampling procedures, from at or near the point of identification (28 – 41 months) through 84 months of age. The children with hearing loss were compared to ten age-matched children with normal hearing on a majority of the measures through 60 months of age. Spontaneous language samples were collected from mother-child interaction sessions, recorded at consistent intervals in a laboratory-based play setting. Transcripts were analyzed using computer-based procedures (Systematic Analysis of Language Transcripts) and the Index of Productive Syntax. Possible influences of audibility were explored by examining the onset and productive use of a set of verb tense markers, and by monitoring the children’s accuracy in use of morphological endings. Phonological samples at baseline were transcribed and analyzed using Computerized Profiling. Results At entry to the study, the four children with hearing loss demonstrated language delays, with pronounced delays in phonological development. Three of the four children demonstrated rapid progress with development and interventions, and performed within the average range on standardized speech and language measures compared to age-matched children by 60-months of age. However, persistent differences from children with normal hearing were observed in the areas of morphosyntax, speech intelligibility in conversation, and production of fricatives. Children with mild-moderate hearing loss demonstrated later than typical emergence of certain verb tense markers, which may be related to reduced or inconsistent audibility. Conclusions The results of this study suggest that early communication delays will resolve for children with late-identified mild-moderate hearing loss, given appropriate amplification and intervention services. A positive result is that three of four children demonstrated normalization of broad language behaviors by 60-months of age, in spite of significant delays at baseline. However, these children are at risk for persistent delays in phonology at the conversational level and for accuracy in use of morphological markers. The ways in which reduced auditory experiences and audibility may contribute to these delays are explored, along with implications for evaluation of outcomes. PMID:20548239

  3. Dead-time compensation for a logarithmic display rate meter

    DOEpatents

    Larson, John A.; Krueger, Frederick P.

    1988-09-20

    An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events.

  4. Dead-time compensation for a logarithmic display rate meter

    DOEpatents

    Larson, J.A.; Krueger, F.P.

    1987-10-05

    An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events. 5 figs.

  5. If you can't take the room out of your mix, you can't take your mix out of the room!

    NASA Astrophysics Data System (ADS)

    D'Antonio, Peter

    2003-04-01

    The key issue in any recording studio is transferability-the ability of a mix to transfer to other listening environments outside the studio. For a mix to faithfully transfer to a wide range of acoustical environments, it must be created in a room with minimal acoustic distortion. The music industry is very aware of electronic distortion; however, the audible effects of acoustic distortion are only now being fully appreciated. The four forms of acoustic distortion are modal coupling, speaker boundary interference response, comb filtering and poor diffusion or a sparse spatial and temporal reflection density. These phenomena will be explained and methods to minimize them will be suggested.

  6. Detection of the large meteoroid/NEO flux using infrasound: recent detection of the November 21, 1995, Colorado fireball

    NASA Astrophysics Data System (ADS)

    Revelle, Douglas O.; Whitaker, Rodney W.

    1996-10-01

    During the early morning of November 21, 1995, a fireball as bright as the full moon entered the atmosphere over southeastern Colorado and initially produced audible sonic boom reports from Texas to Wyoming. The event was detected locally by a security video camera which showed the reflection of the fireball event on the hood of a truck. The camera also recorded tree shadows cast by the light of the fireball. This recording includes the audio signal of a strong double boom as well. Subsequent investigation of the array near Los Alamos, New Mexico operated by the Los Alamos National Laboratory as part of its commitment to the Comprehensive Test Ban Treaty negotiations, showed the presence of an infrasonic signal from the proper direction at about the correct time for this fireball. The Los Alamos array is a four-element infrasonic system in near-continuous operation on the laboratory property. The nominal spacing between the array elements is 212 m. The basic sensor is a Globe Universal Sciences Model 100C microphone whose response is flat from about 0.1 to 300 Hz (which we filter at the high frequency end to be limited to 20 Hz). Each low frequency microphone is connected to a set of twelve porous hoses to reduce wind noise. The characteristics of the observed signal include the onset arrival time of 0939:20 UT (0239:20 MST), with a maximum timing uncertainty of plus or minus 2 minutes, the signal onset time delay from the appearance of the fireball of 21 minutes, 20 seconds, total signal duration of 2 minutes 10 seconds, the source location determined to be toward 31 degrees from true north, the horizontal trace velocity of 429 m/sec, the signal velocity of 0.29 plus or minus 0.03 km/sec, assuming a 375 km horizontal range to the fireball, the dominant signal frequency content of 0.25 to 0.84 Hz (analyzed in the frequency interval from 0.2 to 2.0 Hz), the maximum signal cross-correlation of 0.97 and the maximum signal amplitude of 2.0 plus or minus 0.1 microbars. Also, on the basis of the signal period at maximum amplitude, we estimate a probable source energy for this event of between 10 to 100 tons of TNT (53.0 tons nominal).

  7. West Texas array experiment: Noise and source characterization of short-range infrasound and acoustic signals, along with lab and field evaluation of Intermountain Laboratories infrasound microphones

    NASA Astrophysics Data System (ADS)

    Fisher, Aileen

    The term infrasound describes atmospheric sound waves with frequencies below 20 Hz, while acoustics are classified within the audible range of 20 Hz to 20 kHz. Infrasound and acoustic monitoring in the scientific community is hampered by low signal-to-noise ratios and a limited number of studies on regional and short-range noise and source characterization. The JASON Report (2005) suggests the infrasound community focus on more broad-frequency, observational studies within a tactical distance of 10 km. In keeping with that recommendation, this paper presents a study of regional and short-range atmospheric acoustic and infrasonic noise characterization, at a desert site in West Texas, covering a broad frequency range of 0.2 to 100 Hz. To spatially sample the band, a large number of infrasound gauges was needed. A laboratory instrument analysis is presented of the set of low-cost infrasound sensors used in this study, manufactured by Inter-Mountain Laboratories (IML). Analysis includes spectra, transfer functions and coherences to assess the stability and range of the gauges, and complements additional instrument testing by Sandia National Laboratories. The IMLs documented here have been found reliably coherent from 0.1 to 7 Hz without instrument correction. Corrections were built using corresponding time series from the commercially available and more expensive Chaparral infrasound gauge, so that the corrected IML outputs were able to closely mimic the Chaparral output. Arrays of gauges are needed for atmospheric sound signal processing. Our West Texas experiment consisted of a 1.5 km aperture, 23-gauge infrasound/acoustic array of IMLs, with a compact, 12 m diameter grid-array of rented IMLs at the center. To optimize signal recording, signal-to-noise ratio needs to be quantified with respect to both frequency band and coherence length. The higher-frequency grid array consisted of 25 microphones arranged in a five by five pattern with 3 meter spacing, without spatial wind noise filtering hoses or pipes. The grid was within the distance limits of a single gauge's normal hose array, and data were used to perform a spatial noise correlation study. The highest correlation values were not found in the lower frequencies as anticipated, owing to a lack of sources in the lower range and the uncorrelated nature of wind noise. The highest values, with cross-correlation averages between 0.4 and 0.7 from 3 to 17 m between gauges, were found at night from 10 and 20 Hz due to a continuous local noise source and low wind. Data from the larger array were used to identify continuous and impulsive signals in the area that comprise the ambient noise field. Ground truth infrasound and acoustic, time and location data were taken for a highway site, a wind farm, and a natural gas compressor. Close-range sound data were taken with a single IML "traveler" gauge. Spectrograms and spectrum peaks were used to identify their source signatures. Two regional location techniques were also tested with data from the large array by using a propane cannon as a controlled, impulsive source. A comparison is presented of the Multiple Signal Classification Algorithm (MUSIC) to a simple, quadratic, circular wavefront algorithm. MUSIC was unable to effectively separate noise and source eignenvalues and eigenvectors due to spatial aliasing of the propane cannon signal and a lack of incoherent noise. Only 33 out of 80 usable shots were located by MUSIC within 100 m. Future work with the algorithm should focus on location of impulsive and continuous signals with development of methods for accurate separation of signal and noise eigenvectors in the presence of coherent noise and possible spatial aliasing. The circular wavefront algorithm performed better with our specific dataset and successfully located 70 out of 80 propane cannon shots within 100 m of the original location, 66 of which were within 20 m. This method has low computation requirements, making it well suited for real-time automated processing and smaller computers. Future research could focus on development of the method for an automated system and statistical impulsive noise filtering for higher accuracy.

  8. 16 CFR 1210.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... visual effects, or that depicts (logos, decals, art work, etc.) or resembles in physical form or function... produce a flame; and produces an audible or visual signal that will be clearly discernible when the...

  9. 16 CFR 1210.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... visual effects, or that depicts (logos, decals, art work, etc.) or resembles in physical form or function... produce a flame; and produces an audible or visual signal that will be clearly discernible when the...

  10. Optimization of programming parameters in children with the advanced bionics cochlear implant.

    PubMed

    Baudhuin, Jacquelyn; Cadieux, Jamie; Firszt, Jill B; Reeder, Ruth M; Maxson, Jerrica L

    2012-05-01

    Cochlear implants provide access to soft intensity sounds and therefore improved audibility for children with severe-to-profound hearing loss. Speech processor programming parameters, such as threshold (or T-level), input dynamic range (IDR), and microphone sensitivity, contribute to the recipient's program and influence audibility. When soundfield thresholds obtained through the speech processor are elevated, programming parameters can be modified to improve soft sound detection. Adult recipients show improved detection for low-level sounds when T-levels are set at raised levels and show better speech understanding in quiet when wider IDRs are used. Little is known about the effects of parameter settings on detection and speech recognition in children using today's cochlear implant technology. The overall study aim was to assess optimal T-level, IDR, and sensitivity settings in pediatric recipients of the Advanced Bionics cochlear implant. Two experiments were conducted. Experiment 1 examined the effects of two T-level settings on soundfield thresholds and detection of the Ling 6 sounds. One program set T-levels at 10% of most comfortable levels (M-levels) and another at 10 current units (CUs) below the level judged as "soft." Experiment 2 examined the effects of IDR and sensitivity settings on speech recognition in quiet and noise. Participants were 11 children 7-17 yr of age (mean 11.3) implanted with the Advanced Bionics High Resolution 90K or CII cochlear implant system who had speech recognition scores of 20% or greater on a monosyllabic word test. Two T-level programs were compared for detection of the Ling sounds and frequency modulated (FM) tones. Differing IDR/sensitivity programs (50/0, 50/10, 70/0, 70/10) were compared using Ling and FM tone detection thresholds, CNC (consonant-vowel nucleus-consonant) words at 50 dB SPL, and Hearing in Noise Test for Children (HINT-C) sentences at 65 dB SPL in the presence of four-talker babble (+8 signal-to-noise ratio). Outcomes were analyzed using a paired t-test and a mixed-model repeated measures analysis of variance (ANOVA). T-levels set 10 CUs below "soft" resulted in significantly lower detection thresholds for all six Ling sounds and FM tones at 250, 1000, 3000, 4000, and 6000 Hz. When comparing programs differing by IDR and sensitivity, a 50 dB IDR with a 0 sensitivity setting showed significantly poorer thresholds for low frequency FM tones and voiced Ling sounds. Analysis of group mean scores for CNC words in quiet or HINT-C sentences in noise indicated no significant differences across IDR/sensitivity settings. Individual data, however, showed significant differences between IDR/sensitivity programs in noise; the optimal program differed across participants. In pediatric recipients of the Advanced Bionics cochlear implant device, manually setting T-levels with ascending loudness judgments should be considered when possible or when low-level sounds are inaudible. Study findings confirm the need to determine program settings on an individual basis as well as the importance of speech recognition verification measures in both quiet and noise. Clinical guidelines are suggested for selection of programming parameters in both young and older children. American Academy of Audiology.

  11. Active control of sound transmission through partitions composed of discretely controlled modules

    NASA Astrophysics Data System (ADS)

    Leishman, Timothy W.

    This thesis provides a detailed theoretical and experimental investigation of active segmented partitions (ASPs) for the control of sound transmission. ASPs are physically segmented arrays of interconnected acoustically and structurally small modules that are discretely controlled using electronic controllers. Theoretical analyses of the thesis first address physical principles fundamental to ASP modeling and experimental measurement techniques. Next, they explore specific module configurations, primarily using equivalent circuits. Measured normal-incidence transmission losses and related properties of experimental ASPs are determined using plane wave tubes and the two-microphone transfer function technique. A scanning laser vibrometer is also used to evaluate distributed transmitting surface vibrations. ASPs have the inherent potential to provide excellent active sound transmission control (ASTC) through lightweight structures, using very practical control strategies. The thesis analyzes several unique ASP configurations and evaluates their abilities to produce high transmission losses via global minimization of normal transmitting surface vibrations. A novel dual diaphragm configuration is shown to employ this strategy particularly well. It uses an important combination of acoustical actuation and mechano-acoustical segmentation to produce exceptionally high transmission loss (e.g., 50 to 80 dB) over a broad frequency range-including lower audible frequencies. Such performance is shown to be comparable to that produced by much more massive partitions composed of thick layers of steel or concrete and sand. The configuration uses only simple localized error sensors and actuators, permitting effective use of independent single-channel controllers in a decentralized format. This work counteracts the commonly accepted notion that active vibration control of partitions is an ineffective means of controlling sound transmission. With appropriate construction, actuation, and error sensing, ASPs can achieve high sound transmission loss through efficient global control of transmitting surface vibrations. This approach is applicable to a wide variety of source and receiving spaces-and to both near fields and far fields.

  12. The viscoelastic effect in bending bucky-gel actuators

    NASA Astrophysics Data System (ADS)

    Kruusamäe, Karl; Mukai, Ken; Sugino, Takushi; Asaka, Kinji

    2014-03-01

    Electromechanically active polymers (EAP) are considered a good actuator candidate for a variety of reasons, e.g. they are soft, easy to miniaturize and operate without audible noise. The main structural component in EAPs is, as the name states, a type of deformable polymer. As polymers are known to exhibit a distinct mechanical response, the nature of polymer materials should never be neglected when characterizing and modeling the performance of EAP actuators. Bucky-gel actuators are a subtype of EAPs where ion-containing polymer membrane acts as an electronically insulating separator between two electrodes of carbon nanotubes and ionic liquid. In many occasions, the electrodes also contain polymer for the purpose of binding it together. Therefore, mechanically speaking, bucky-gel actuators are composite structures with layers of different mechanical nature. The viscoelastic response and the shape change property are perhaps the most characteristic effects in polymers. These effects are known to have high dependence on factors such as the type of polymer, the concentration of additives and the structural ratio of different layers. At the same time, most reports about optimization of EAP actuators describe the alteration of electromechanical performance dependent on the same factors. In this paper, the performance of bucky-gel actuators is measured as a function between the output force and bending deflection. It is observed that effective stiffness of these actuators depends on the input voltage. This finding is also supported by dynamic mechanical analysis which demonstrates that the viscoelastic response of bucky-gel laminate depends on both frequency and temperature. Moreover, the dynamic mechanical analysis reveals that in the range of standard operation temperatures, tested samples were in their glass transition region, which made it possible to alter their shape by using mechanical fixing. The mechanical fixity above 90% was obtained when high-frequency input signal was used to heat the bucky-gel sample.

  13. Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers.

    PubMed

    Shetty, Hemanth Narayan; Puttabasappa, Manjula

    Hearing aids are prescribed to alleviate loss of audibility. It has been reported that about 31% of hearing aid users reject their own hearing aid because of annoyance towards background noise. The reason for dissatisfaction can be located anywhere from the hearing aid microphone till the integrity of neurons along the auditory pathway. To measure spectra from the output of hearing aid at the ear canal level and frequency following response recorded at the auditory brainstem from individuals with hearing impairment. A total of sixty participants having moderate sensorineural hearing impairment with age range from 15 to 65 years were involved. Each participant was classified as either Good or Poor Hearing aid Performers based on acceptable noise level measure. Stimuli /da/ and /si/ were presented through loudspeaker at 65dB SPL. At the ear canal, the spectra were measured in the unaided and aided conditions. At auditory brainstem, frequency following response were recorded to the same stimuli from the participants. Spectrum measured in each condition at ear canal was same in good hearing aid performers and poor hearing aid performers. At brainstem level, better F 0 encoding; F 0 and F 1 energies were significantly higher in good hearing aid performers than in poor hearing aid performers. Though the hearing aid spectra were almost same between good hearing aid performers and poor hearing aid performers, subtle physiological variations exist at the auditory brainstem. The result of the present study suggests that neural encoding of speech sound at the brainstem level might be mediated distinctly in good hearing aid performers from that of poor hearing aid performers. Thus, it can be inferred that subtle physiological changes are evident at the auditory brainstem in a person who is willing to accept noise from those who are not willing to accept noise. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  14. 16 CFR § 1210.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... visual effects, or that depicts (logos, decals, art work, etc.) or resembles in physical form or function... produce a flame; and produces an audible or visual signal that will be clearly discernible when the...

  15. 49 CFR 382.103 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... who are required to wear military uniforms), and active duty U.S. Coast Guard personnel; or (3) Who a... governmental functions, are equipped with audible and visual signals, and are not subject to normal traffic...

  16. 49 CFR 382.103 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... who are required to wear military uniforms), and active duty U.S. Coast Guard personnel; or (3) Who a... governmental functions, are equipped with audible and visual signals, and are not subject to normal traffic...

  17. 49 CFR 382.103 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... who are required to wear military uniforms), and active duty U.S. Coast Guard personnel; or (3) Who a... governmental functions, are equipped with audible and visual signals, and are not subject to normal traffic...

  18. 49 CFR 382.103 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... who are required to wear military uniforms), and active duty U.S. Coast Guard personnel; or (3) Who a... governmental functions, are equipped with audible and visual signals, and are not subject to normal traffic...

  19. 49 CFR 382.103 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... who are required to wear military uniforms), and active duty U.S. Coast Guard personnel; or (3) Who a... governmental functions, are equipped with audible and visual signals, and are not subject to normal traffic...

  20. Design and analysis of ultrasonic monaural audio guiding device for the visually impaired.

    PubMed

    Kim, Keonwook; Kim, Hyunjai; Yun, Gihun; Kim, Myungsoo

    2009-01-01

    The novel Audio Guiding Device (AGD) based on the ultrasonic, which is named as SonicID, has been developed in order to localize point of interest for the visually impaired. The SonicID requires the infrastructure of the transmitters for broadcasting the location information over the ultrasonic carrier. The user with ultrasonic headset receives the information with variable amplitude upon the location and direction of the user due to the ultrasonic characteristic and modulation method. This paper proposes the monaural headset form factor of the SonicID which improves the daily life of the beneficiary compare to the previous version which uses the both ears. Experimental results from SonicID, Bluetooth, and audible sound show that the SonicID demonstrates comparable localization performance to the audible sound with silence to others.

  1. Perception of the Multisensory Coherence of Fluent Audiovisual Speech in Infancy: Its Emergence & the Role of Experience

    PubMed Central

    Lewkowicz, David J.; Minar, Nicholas J.; Tift, Amy H.; Brandon, Melissa

    2014-01-01

    To investigate the developmental emergence of the ability to perceive the multisensory coherence of native and non-native audiovisual fluent speech, we tested 4-, 8–10, and 12–14 month-old English-learning infants. Infants first viewed two identical female faces articulating two different monologues in silence and then in the presence of an audible monologue that matched the visible articulations of one of the faces. Neither the 4-month-old nor the 8–10 month-old infants exhibited audio-visual matching in that neither group exhibited greater looking at the matching monologue. In contrast, the 12–14 month-old infants exhibited matching and, consistent with the emergence of perceptual expertise for the native language, they perceived the multisensory coherence of native-language monologues earlier in the test trials than of non-native language monologues. Moreover, the matching of native audible and visible speech streams observed in the 12–14 month olds did not depend on audio-visual synchrony whereas the matching of non-native audible and visible speech streams did depend on synchrony. Overall, the current findings indicate that the perception of the multisensory coherence of fluent audiovisual speech emerges late in infancy, that audio-visual synchrony cues are more important in the perception of the multisensory coherence of non-native than native audiovisual speech, and that the emergence of this skill most likely is affected by perceptual narrowing. PMID:25462038

  2. Perception of the multisensory coherence of fluent audiovisual speech in infancy: its emergence and the role of experience.

    PubMed

    Lewkowicz, David J; Minar, Nicholas J; Tift, Amy H; Brandon, Melissa

    2015-02-01

    To investigate the developmental emergence of the perception of the multisensory coherence of native and non-native audiovisual fluent speech, we tested 4-, 8- to 10-, and 12- to 14-month-old English-learning infants. Infants first viewed two identical female faces articulating two different monologues in silence and then in the presence of an audible monologue that matched the visible articulations of one of the faces. Neither the 4-month-old nor 8- to 10-month-old infants exhibited audiovisual matching in that they did not look longer at the matching monologue. In contrast, the 12- to 14-month-old infants exhibited matching and, consistent with the emergence of perceptual expertise for the native language, perceived the multisensory coherence of native-language monologues earlier in the test trials than that of non-native language monologues. Moreover, the matching of native audible and visible speech streams observed in the 12- to 14-month-olds did not depend on audiovisual synchrony, whereas the matching of non-native audible and visible speech streams did depend on synchrony. Overall, the current findings indicate that the perception of the multisensory coherence of fluent audiovisual speech emerges late in infancy, that audiovisual synchrony cues are more important in the perception of the multisensory coherence of non-native speech than that of native audiovisual speech, and that the emergence of this skill most likely is affected by perceptual narrowing. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Relation between Working Memory Capacity and Auditory Stream Segregation in Children with Auditory Processing Disorder

    PubMed Central

    Lotfi, Yones; Mehrkian, Saiedeh; Moossavi, Abdollah; Zadeh, Soghrat Faghih; Sadjedi, Hamed

    2016-01-01

    Background: This study assessed the relationship between working memory capacity and auditory stream segregation by using the concurrent minimum audible angle in children with a diagnosed auditory processing disorder (APD). Methods: The participants in this cross-sectional, comparative study were 20 typically developing children and 15 children with a diagnosed APD (age, 9–11 years) according to the subtests of multiple-processing auditory assessment. Auditory stream segregation was investigated using the concurrent minimum audible angle. Working memory capacity was evaluated using the non-word repetition and forward and backward digit span tasks. Nonparametric statistics were utilized to compare the between-group differences. The Pearson correlation was employed to measure the degree of association between working memory capacity and the localization tests between the 2 groups. Results: The group with APD had significantly lower scores than did the typically developing subjects in auditory stream segregation and working memory capacity. There were significant negative correlations between working memory capacity and the concurrent minimum audible angle in the most frontal reference location (0° azimuth) and lower negative correlations in the most lateral reference location (60° azimuth) in the children with APD. Conclusion: The study revealed a relationship between working memory capacity and auditory stream segregation in children with APD. The research suggests that lower working memory capacity in children with APD may be the possible cause of the inability to segregate and group incoming information. PMID:26989281

  4. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs. (b) Classification. Class II (special controls). The guidance...

  5. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs. (b) Classification. Class II (special controls). The guidance...

  6. 46 CFR 160.151-57 - Servicing procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... its weight loss exceeds five percent of the weight of the charge, it must be recharged. (c) When an... in the buoyancy tubes is audible, accompanied by pressure loss, condemn the liferaft. If it is not...

  7. Zones of impact around icebreakers affecting beluga whales in the Beaufort Sea.

    PubMed

    Erbe, C; Farmer, D M

    2000-09-01

    A software model estimating zones of impact on marine mammals around man-made noise [C. Erbe and D. M. Farmer, J. Acoust. Soc. Am. 108, 1327-1331 (2000)] is applied to the case of icebreakers affecting beluga whales in the Beaufort Sea. Two types of noise emitted by the Canadian Coast Guard icebreaker Henry Larsen are analyzed: bubbler system noise and propeller cavitation noise. Effects on beluga whales are modeled both in a deep-water environment and a near-shore environment. The model estimates that the Henry Larsen is audible to beluga whales over ranges of 35-78 km, depending on location. The zone of behavioral disturbance is only slightly smaller. Masking of beluga communication signals is predicted within 14-71-km range. Temporary hearing damage can occur if a beluga stays within 1-4 km of the Henry Larsen for at least 20 min. Bubbler noise impacts over the short ranges quoted; propeller cavitation noise accounts for all the long-range effects. Serious problems can arise in heavily industrialized areas where animals are exposed to ongoing noise and where anthropogenic noise from a variety of sources adds up.

  8. Computational Approach to Musical Consonance and Dissonance

    PubMed Central

    Trulla, Lluis L.; Di Stefano, Nicola; Giuliani, Alessandro

    2018-01-01

    In sixth century BC, Pythagoras discovered the mathematical foundation of musical consonance and dissonance. When auditory frequencies in small-integer ratios are combined, the result is a harmonious perception. In contrast, most frequency combinations result in audible, off-centered by-products labeled “beating” or “roughness;” these are reported by most listeners to sound dissonant. In this paper, we consider second-order beats, a kind of beating recognized as a product of neural processing, and demonstrate that the data-driven approach of Recurrence Quantification Analysis (RQA) allows for the reconstruction of the order in which interval ratios are ranked in music theory and harmony. We take advantage of computer-generated sounds containing all intervals over the span of an octave. To visualize second-order beats, we use a glissando from the unison to the octave. This procedure produces a profile of recurrence values that correspond to subsequent epochs along the original signal. We find that the higher recurrence peaks exactly match the epochs corresponding to just intonation frequency ratios. This result indicates a link between consonance and the dynamical features of the signal. Our findings integrate a new element into the existing theoretical models of consonance, thus providing a computational account of consonance in terms of dynamical systems theory. Finally, as it considers general features of acoustic signals, the present approach demonstrates a universal aspect of consonance and dissonance perception and provides a simple mathematical tool that could serve as a common framework for further neuro-psychological and music theory research. PMID:29670552

  9. An Ultrasonic Contactless Sensor for Breathing Monitoring

    PubMed Central

    Arlotto, Philippe; Grimaldi, Michel; Naeck, Roomila; Ginoux, Jean-Marc

    2014-01-01

    The monitoring of human breathing activity during a long period has multiple fundamental applications in medicine. In breathing sleep disorders such as apnea, the diagnosis is based on events during which the person stops breathing for several periods during sleep. In polysomnography, the standard for sleep disordered breathing analysis, chest movement and airflow are used to monitor the respiratory activity. However, this method has serious drawbacks. Indeed, as the subject should sleep overnight in a laboratory and because of sensors being in direct contact with him, artifacts modifying sleep quality are often observed. This work investigates an analysis of the viability of an ultrasonic device to quantify the breathing activity, without contact and without any perception by the subject. Based on a low power ultrasonic active source and transducer, the device measures the frequency shift produced by the velocity difference between the exhaled air flow and the ambient environment, i.e., the Doppler effect. After acquisition and digitization, a specific signal processing is applied to separate the effects of breath from those due to subject movements from the Doppler signal. The distance between the source and the sensor, about 50 cm, and the use of ultrasound frequency well above audible frequencies, 40 kHz, allow monitoring the breathing activity without any perception by the subject, and therefore without any modification of the sleep quality which is very important for sleep disorders diagnostic applications. This work is patented (patent pending 2013-7-31 number FR.13/57569). PMID:25140632

  10. Remotely Exploring Deeper-Into-Matter by Non-Contact Detection of Audible Transients Excited by Laser Radiation

    PubMed Central

    Moros, Javier; Gaona, Inmaculada; Laserna, J. Javier

    2017-01-01

    An acoustic spectroscopic approach to detect contents within different packaging, with substantially wider applicability than other currently available subsurface spectroscopies, is presented. A frequency-doubled Nd:YAG (neodymium-doped yttrium aluminum garnet) pulsed laser (13 ns pulse length) operated at 1 Hz was used to generate the sound field of a two-component system at a distance of 50 cm. The acoustic emission was captured using a unidirectional microphone and analyzed in the frequency domain. The focused laser pulse hitting the system, with intensity above that necessary to ablate the irradiated surface, transferred an impulsive force which led the structure to vibrate. Acoustic airborne transients were directly radiated by the vibrating elastic structure of the outer component that excited the surrounding air in contact with. However, under boundary conditions, sound field is modulated by the inner component that modified the dynamical integrity of the system. Thus, the resulting frequency spectra are useful indicators of the concealed content that influences the contributions originating from the wall of the container. High-quality acoustic spectra could be recorded from a gas (air), liquid (water), and solid (sand) placed inside opaque chemical-resistant polypropylene and stainless steel sample containers. Discussion about effects of laser excitation energy and sampling position on the acoustic emission events is reported. Acoustic spectroscopy may complement the other subsurface alternative spectroscopies, severely limited by their inherent optical requirements for numerous detection scenarios. PMID:29261126

  11. Photoacoustic sounds from meteors

    DOE PAGES

    Spalding, Richard; Tencer, John; Sweatt, William; ...

    2017-02-01

    Concurrent sound associated with very bright meteors manifests as popping, hissing, and faint rustling sounds occurring simultaneously with the arrival of light from meteors. Numerous instances have been documented with –11 to –13 brightness. These sounds cannot be attributed to direct acoustic propagation from the upper atmosphere for which travel time would be several minutes. Concurrent sounds must be associated with some form of electromagnetic energy generated by the meteor, propagated to the vicinity of the observer, and transduced into acoustic waves. Previously, energy propagated from meteors was assumed to be RF emissions. This has not been well validated experimentally.more » Herein we describe experimental results and numerical models in support of photoacoustic coupling as the mechanism. Recent photometric measurements of fireballs reveal strong millisecond flares and significant brightness oscillations at frequencies ≥40 Hz. Strongly modulated light at these frequencies with sufficient intensity can create concurrent sounds through radiative heating of common dielectric materials like hair, clothing, and leaves. This heating produces small pressure oscillations in the air contacting the absorbers. Calculations show that –12 brightness meteors can generate audible sound at ~25 dB SPL. As a result, the photoacoustic hypothesis provides an alternative explanation for this longstanding mystery about generation of concurrent sounds by fireballs.« less

  12. A correlational method to concurrently measure envelope and temporal fine structure weights: effects of age, cochlear pathology, and spectral shaping.

    PubMed

    Fogerty, Daniel; Humes, Larry E

    2012-09-01

    The speech signal may be divided into spectral frequency-bands, each band containing temporal properties of the envelope and fine structure. This study measured the perceptual weights for the envelope and fine structure in each of three frequency bands for sentence materials in young normal-hearing listeners, older normal-hearing listeners, aided older hearing-impaired listeners, and spectrally matched young normal-hearing listeners. The availability of each acoustic property was independently varied through noisy signal extraction. Thus, the full speech stimulus was presented with noise used to mask six different auditory channels. Perceptual weights were determined by correlating a listener's performance with the signal-to-noise ratio of each acoustic property on a trial-by-trial basis. Results demonstrate that temporal fine structure perceptual weights remain stable across the four listener groups. However, a different weighting typography was observed across the listener groups for envelope cues. Results suggest that spectral shaping used to preserve the audibility of the speech stimulus may alter the allocation of perceptual resources. The relative perceptual weighting of envelope cues may also change with age. Concurrent testing of sentences repeated once on a previous day demonstrated that weighting strategies for all listener groups can change, suggesting an initial stabilization period or susceptibility to auditory training.

  13. Predicting word-recognition performance in noise by young listeners with normal hearing using acoustic, phonetic, and lexical variables.

    PubMed

    McArdle, Rachel; Wilson, Richard H

    2008-06-01

    To analyze the 50% correct recognition data that were from the Wilson et al (this issue) study and that were obtained from 24 listeners with normal hearing; also to examine whether acoustic, phonetic, or lexical variables can predict recognition performance for monosyllabic words presented in speech-spectrum noise. The specific variables are as follows: (a) acoustic variables (i.e., effective root-mean-square sound pressure level, duration), (b) phonetic variables (i.e., consonant features such as manner, place, and voicing for initial and final phonemes; vowel phonemes), and (c) lexical variables (i.e., word frequency, word familiarity, neighborhood density, neighborhood frequency). The descriptive, correlational study will examine the influence of acoustic, phonetic, and lexical variables on speech recognition in noise performance. Regression analysis demonstrated that 45% of the variance in the 50% point was accounted for by acoustic and phonetic variables whereas only 3% of the variance was accounted for by lexical variables. These findings suggest that monosyllabic word-recognition-in-noise is more dependent on bottom-up processing than on top-down processing. The results suggest that when speech-in-noise testing is used in a pre- and post-hearing-aid-fitting format, the use of monosyllabic words may be sensitive to changes in audibility resulting from amplification.

  14. Eddy current inspection tool which is selectively operable in a discontinuity detection mode and a discontinuity magnitude mode

    DOEpatents

    Petrini, Richard R.; Van Lue, Dorin F.

    1983-01-01

    A miniaturized inspection tool, for testing and inspection of metal objects in locations with difficult accessibility, which comprises eddy current sensing equipment (12) with a probe coil (11), and associated coaxial coil cable (13), coil energizing means (21), and circuit means (21, 12) responsive to impedance changes in the coil as effected by induced eddy currents in a test object to produce a data output signal proportional to such changes. The coil and cable are slideably received in the utility channel of the flexible insertion tube 17 of fiberoptic scope 10. The scope 10 is provided with light transmitting and receiving fiberoptics for viewing through the flexible tube, and articulation means (19, 20) for articulating the distal end of the tube and permitting close control of coil placement relative to a test object. The eddy current sensing equipment includes a tone generator 30 for generating audibly signals responsive to the data output signal. In one selected mode of operation, the tone generator responsive to the output signal above a selected level generates a constant single frequency tone for signalling detection of a discontinuity and, in a second selected mode, generates a tone whose frequency is proportional to the difference between the output signal and a predetermined selected threshold level.

  15. Eddy current inspection tool which is selectively operable in a discontinuity detection mode and a discontinuity magnitude mode

    DOEpatents

    Petrini, R.R.; Van Lue, D.F.

    1983-10-25

    A miniaturized inspection tool, for testing and inspection of metal objects in locations with difficult accessibility, which comprises eddy current sensing equipment with a probe coil, and associated coaxial coil cable, coil energizing means, and circuit means responsive to impedance changes in the coil as effected by induced eddy currents in a test object to produce a data output signal proportional to such changes. The coil and cable are slideably received in the utility channel of the flexible insertion tube of fiberoptic scope. The scope is provided with light transmitting and receiving fiberoptics for viewing through the flexible tube, and articulation means for articulating the distal end of the tube and permitting close control of coil placement relative to a test object. The eddy current sensing equipment includes a tone generator 30 for generating audibly signals responsive to the data output signal. In one selected mode of operation, the tone generator responsive to the output signal above a selected level generates a constant single frequency tone for signaling detection of a discontinuity and, in a second selected mode, generates a tone whose frequency is proportional to the difference between the output signal and a predetermined selected threshold level. 5 figs.

  16. Why credible propeller noise measurements are possible in the acoustically untreated NASA Lewis 8 ft by 6 ft wind tunnel

    NASA Technical Reports Server (NTRS)

    Dittmar, J. H.

    1984-01-01

    An explanation is presented for the lack of acoustic reflections in noise studies of propfan models in the NASA-Lewis 8 x 6 ft wind tunnel, where trials were run at Mach numbers 0.5-0.85. The highly directional propeller noise, i.e., mainly in the plane of rotation, experiences a convective effect due to the high subsonic axial Mach number. Reflected sounds are carried downstream, out of range of the acoustic sensors in the tunnel. Furthermore, reflected noise is less audible, and therefore does not affect measurements near peak values. It is suggested that some data contamination may occur below Mach 0.6, and that measurements be performed on higher harmonics generated by low level reflected noise.

  17. Sonification Prototype for Space Physics

    NASA Astrophysics Data System (ADS)

    Candey, R. M.; Schertenleib, A. M.; Diaz Merced, W. L.

    2005-12-01

    As an alternative and adjunct to visual displays, auditory exploration of data via sonification (data controlled sound) and audification (audible playback of data samples) is promising for complex or rapidly/temporally changing visualizations, for data exploration of large datasets (particularly multi-dimensional datasets), and for exploring datasets in frequency rather than spatial dimensions (see also International Conferences on Auditory Display ). Besides improving data exploration and analysis for most researchers, the use of sound is especially valuable as an assistive technology for visually-impaired people and can make science and math more exciting for high school and college students. Only recently have the hardware and software come together to make a cross-platform open-source sonification tool feasible. We have developed a prototype sonification data analysis tool using the JavaSound API and NASA GSFC's ViSBARD software . Wanda Diaz Merced, a blind astrophysicist from Puerto Rico, is instrumental in advising on and testing the tool.

  18. Ultrafast imaging of cell elasticity with optical microelastography

    PubMed Central

    Grasland-Mongrain, Pol; Zorgani, Ali; Nakagawa, Shoma; Bernard, Simon; Paim, Lia Gomes; Fitzharris, Greg; Catheline, Stefan

    2018-01-01

    Elasticity is a fundamental cellular property that is related to the anatomy, functionality, and pathological state of cells and tissues. However, current techniques based on cell deformation, atomic force microscopy, or Brillouin scattering are rather slow and do not always accurately represent cell elasticity. Here, we have developed an alternative technique by applying shear wave elastography to the micrometer scale. Elastic waves were mechanically induced in live mammalian oocytes using a vibrating micropipette. These audible frequency waves were observed optically at 200,000 frames per second and tracked with an optical flow algorithm. Whole-cell elasticity was then mapped using an elastography method inspired by the seismology field. Using this approach we show that the elasticity of mouse oocytes is decreased when the oocyte cytoskeleton is disrupted with cytochalasin B. The technique is fast (less than 1 ms for data acquisition), precise (spatial resolution of a few micrometers), able to map internal cell structures, and robust and thus represents a tractable option for interrogating biomechanical properties of diverse cell types. PMID:29339488

  19. Automatic Recognition of Underground Targets Using Time-Frequency Analysis and Optimization Techniques

    NASA Astrophysics Data System (ADS)

    Gaunaurd, Guillermo C.; Strifors, Hans C.

    Landmines have been laid in conflicts around the world, and they cause enormous humanitarian problems in more than 60 countries, killing, mutilating, or maiming the innocent every day. They do not differentiate between elderly, men, women, children, or animals, and they are triggered off by the victims themselves. Detection and clearance of landmines, however, have turned out to be an immensely challenging problem. A traditional means for detecting mines is the metal detector. The detector head is slowly moved over the suspicious terrain, and it gives out audible alerts when metal in the ground disturbs the magnetic field the detector generates. In general, the number of false alarms caused by various (man-made) metal objects in the ground is a great deal larger than the number of mines. This makes mine clearance a tiring task that demands the highest level of concentration. Moreover, a hazard involved is that the metal detector could be too insensitive to mines of low-metal content.

  20. Through-the-earth radio

    DOEpatents

    Reagor, David [Los Alamos, NM; Vasquez-Dominguez, Jose [Los Alamos, NM

    2006-05-09

    A method and apparatus for effective through-the-earth communication involves a signal input device connected to a transmitter operating at a predetermined frequency sufficiently low to effectively penetrate useful distances through-the earth, and having an analog to digital converter receiving the signal input and passing the signal input to a data compression circuit that is connected to an encoding processor, the encoding processor output being provided to a digital to analog converter. An amplifier receives the analog output from the digital to analog converter for amplifying said analog output and outputting said analog output to an antenna. A receiver having an antenna receives the analog output passes the analog signal to a band pass filter whose output is connected to an analog to digital converter that provides a digital signal to a decoding processor whose output is connected to an data decompressor, the data decompressor providing a decompressed digital signal to a digital to analog converter. An audio output device receives the analog output form the digital to analog converter for producing audible output.

  1. Strategic Acoustic Control of a Hummingbird Courtship Dive.

    PubMed

    Clark, Christopher J; Mistick, Emily A

    2018-04-23

    Male hummingbirds court females with a high-speed dive in which they "sing" with their tail feathers. The male's choice of trajectory provides him strategic control over acoustic frequency and pressure levels heard by the female. Unlike related species, male Costa's hummingbirds (Calypte costae) choose to place their dives to the side of females. Here we show that this minimizes an audible Doppler curve in their dive sound, thereby depriving females of an acoustic indicator that would otherwise reveal male dive speed. Wind-tunnel experiments indicate that the sounds produced by their feathers are directional; thus, males should aim their tail toward females. High-speed video of dives reveal that males twist half of their tail vertically during the dive, which acoustic-camera video shows effectively aims this sound sideways, toward the female. Our results demonstrate that male animals can strategically modulate female perception of dynamic aspects of athletic motor displays, such as their speed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Relationship between thoracic auscultation and lung pathology detected by ultrasonography in sheep.

    PubMed

    Scott, Phil; Collie, Dave; McGorum, Bruce; Sargison, Neil

    2010-10-01

    The utility of routine auscultation to detect and characterise the nature of a range of superficial lung and pleural pathologies in domestic sheep was assessed using ultrasonographic examination to indicate and localise pathologies pre-mortem. Necropsy examination was then used to fully characterise the nature and extent of the lesions. Auscultation recordings were made from 10 normal sheep with no clinical evidence of respiratory disease and with absence of significant superficial lung pathology, which was confirmed initially by ultrasound examination and subsequently at necropsy examination. A further two sheep with endotoxaemia and 30 sheep with well-defined lung lesions were also examined. Increased audibility of normal lung sounds in 4/10 normal sheep was associated with tachypnoea as a consequence of handling and transport during hot weather and was also observed in the two sheep with endotoxaemia. Moderate to severe coarse crackles detected in all advanced cases of ovine pulmonary adenocarcinoma (n=16) were audible over an area larger than the lesion distribution identified during ultrasound examination, and confirmed later at necropsy. Auscultation did not detect abnormal sounds in any of the five sheep with focal pleural abscesses (up to 10 cm diameter). Unilateral pyothorax caused attenuation of sounds relative to the contra-lateral normal lung in all three sheep with this condition. Marked fibrinous pleurisy caused attenuation of sounds relative to normal areas of lung in six sheep. No sounds resembling the description of pleural frictions rubs were heard in the sheep with marked fibrinous pleurisy (n=6) or associated with focal pleural abscesses (n=5). Routine interpretation of auscultated sound did not allow the presence of superficial lung pathology or its distribution to be accurately defined in the respiratory diseases represented in this study. Copyright © 2009 Elsevier Ltd. All rights reserved.

  3. Initial utility experience with cluster of three Mod-2 wind turbine systems

    NASA Technical Reports Server (NTRS)

    Seely, D. B.; Warchol, E. J.; Butler, N. G.; Ciranny, S.

    1982-01-01

    This paper describes the initial utility experiences of operating three MOD-2s during the Engineering Acceptance Testing. Electrical quantities of bus voltage, phase currents and power are initially being recorded to evaluate impacts to customers on the 69-kV subtransmission line during synchronization and operation of one or more WTSs. To date, effects on the system have been essentially undetectable. Measurements of television signal strengths were taken at an existing television remote pickup and relay station at the WTS site. Potential TV signal interference problems from the WTSs have been avoided by replacing the remote pickups with microwave repeater links for the four TV channels received from Portland, Oregon. Preliminary measurements of audible and sub-audible noise levels indicate that the upwind rotor, tubular tower design of the MOD-2 does not have the pulsing high intensity infrasound problems experienced by the MOD-1 machine at Boone, North Carolina.

  4. Metronome rate and walking foot contact time in young adults.

    PubMed

    Dickstein, Ruth; Plax, Michael

    2012-02-01

    It is assumed that when people walk guided by an audible constant rate, they match foot contact to the external pace. The purpose of this preliminary study was to test that assumption by examining the temporal relationship between audible signals generated by a metronome and foot contact time during gait. Ten healthy young women were tested in walking repetitions guided by metronome rates of 60, 110, and 150 beats/min. Metronome beats and foot contact times were collected in real time. The findings indicated that foot contact was not fully synchronized with the auditory signals; the shortest time interval between the metronome beat and foot contact time was at the prescribed rate of 60 beats/min., while the longest interval was at the rate of 150 beats/min. The correlation between left and right foot contact times was highest with the slowest rate and lowest with the fastest rate.

  5. Neurophysiological evidence of efference copies to inner speech

    PubMed Central

    Jack, Bradley N; Pearson, Daniel; Griffiths, Oren; Luque, David; Harris, Anthony WF; Spencer, Kevin M; Le Pelley, Mike E

    2017-01-01

    Efference copies refer to internal duplicates of movement-producing neural signals. Their primary function is to predict, and often suppress, the sensory consequences of willed movements. Efference copies have been almost exclusively investigated in the context of overt movements. The current electrophysiological study employed a novel design to show that inner speech – the silent production of words in one’s mind – is also associated with an efference copy. Participants produced an inner phoneme at a precisely specified time, at which an audible phoneme was concurrently presented. The production of the inner phoneme resulted in electrophysiological suppression, but only if the content of the inner phoneme matched the content of the audible phoneme. These results demonstrate that inner speech – a purely mental action – is associated with an efference copy with detailed auditory properties. These findings suggest that inner speech may ultimately reflect a special type of overt speech. PMID:29199947

  6. The Recognizability and Localizability of Auditory Alarms: Setting Global Medical Device Standards.

    PubMed

    Edworthy, Judy; Reid, Scott; McDougall, Siné; Edworthy, Jonathan; Hall, Stephanie; Bennett, Danielle; Khan, James; Pye, Ellen

    2017-11-01

    Objective Four sets of eight audible alarms matching the functions specified in IEC 60601-1-8 were designed using known principles from auditory cognition with the intention that they would be more recognizable and localizable than those currently specified in the standard. Background The audible alarms associated with IEC 60601-1-8, a global medical device standard, are known to be difficult to learn and retain, and there have been many calls to update them. There are known principles of design and cognition that might form the basis of more readily recognizable alarms. There is also scope for improvement in the localizability of the existing alarms. Method Four alternative sets of alarms matched to the functions specified in IEC 60601-1-8 were tested for recognizability and localizability and compared with the alarms currently specified in the standard. Results With a single exception, all prototype sets of alarms outperformed the current IEC set on both recognizability and localizability. Within the prototype sets, auditory icons were the most easily recognized, but the other sets, using word rhythms and simple acoustic metaphors, were also more easily recognized than the current alarms. With the exception of one set, all prototype sets were also easier to localize. Conclusion Known auditory cognition and perception principles were successfully applied to an existing audible alarm problem. Application This work constitutes the first (benchmarking) phase of replacing the alarms currently specified in the standard. The design principles used for each set demonstrate the relative ease with which different alarm types can be recognized and localized.

  7. Evaluation of the effectiveness of centerline rumble stripes on rural roads.

    DOT National Transportation Integrated Search

    2015-03-01

    This report documents the site characteristics, constructability, summary of audibility testing, and maintenance response of centerline rumble : stripes at two locations: US Route 4 in Mendon-Killington and VT Route 105 in Sheldon. : The primary obje...

  8. 49 CFR 393.75 - Tires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Has body ply or belt material exposed through the tread or sidewall, (2) Has any tread or sidewall separation, (3) Is flat or has an audible leak, or (4) Has a cut to the extent that the ply or belt material...

  9. 49 CFR 393.75 - Tires.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Has body ply or belt material exposed through the tread or sidewall, (2) Has any tread or sidewall separation, (3) Is flat or has an audible leak, or (4) Has a cut to the extent that the ply or belt material...

  10. 49 CFR 393.75 - Tires.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Has body ply or belt material exposed through the tread or sidewall, (2) Has any tread or sidewall separation, (3) Is flat or has an audible leak, or (4) Has a cut to the extent that the ply or belt material...

  11. 49 CFR 393.75 - Tires.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Has body ply or belt material exposed through the tread or sidewall, (2) Has any tread or sidewall separation, (3) Is flat or has an audible leak, or (4) Has a cut to the extent that the ply or belt material...

  12. 49 CFR 393.75 - Tires.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Has body ply or belt material exposed through the tread or sidewall, (2) Has any tread or sidewall separation, (3) Is flat or has an audible leak, or (4) Has a cut to the extent that the ply or belt material...

  13. Computers for Interactive Learning.

    ERIC Educational Resources Information Center

    Grabowski, Barbara; Aggen, William

    1984-01-01

    Analyzes features of computer-based interactive video including sophisticated answer judging, diagnostic feedback, simulation, animation, audible tones, touch sensitive screen, function keys, and video enhancements, and matches these to the characteristics and pedagogical styles of learners. The learner characteristics discussed include internal…

  14. Development of a Lead-free Piezoelectric (K,Na)NbO3 Thin Film Deposited on Nickel-based Electrodes

    NASA Astrophysics Data System (ADS)

    Bani Milhim, Alaeddin

    It is desirable to replace noble metals used as electrode materials for piezoelectric thin film with base metals. This will reduce the piezoelectric thin film fabrication cost. A nickel?based layer in conjunction with other protective layers is proposed as a bottom electrode for lead-free piezoelectric KNN thin film. The obtained results do not indicate the oxidation of the nickel?based bottom electrode after the deposition of KNN at 600 °C for 10 hours in the presence of oxygen and/or after annealing the sample at 400 °C for an hour in air. The fabricated KNN thin film was fully characterized in this work. The effective piezoelectric coefficients d33 and d31 were estimated to be 37 pm/V and 17.2 pm/V, respectively, at 100 kV/cm. The piezoelectric properties of the fabricated KNN/Ni/Ti/SiO2/Si are affected by the crystal orientation of the KNN layer, which was preferentially oriented in the (110) direction. Optimization of the deposition parameters of the fabricated KNN/Ni/Ti/SiO2/Si film is expected to further enhance the piezoelectric properties. Two novel systems utilizing the developed KNN piezoelectric thin film are proposed and their performance simulated based on the achieved KNN thin film parameters. The first is a precision automated nanomanipulation system using an AFM as a sensor and piezo-actuated manipulators. Real-time feedback of the particle being manipulated can be achieved using the proposed system. The length of the manipulators needs to be at least 2 mm to be incorporated with a commercial AFM system. To fabricate the required manipulators, a three-step electrochemical etching technique was developed. Tungsten tips combining well-defined conical shape, a length as large as 2 mm, and sharpness with a radius of curvature of around 20 nm were fabricated using the proposed technique. By depositing the KNN thin film on the fabricated manipulator, nanomanipulators with out-of-plane actuation can be produced. Ultrasonic piezoelectric fan array, the second system, is proposed for GPU cooling applications. The developed KNN thin film is proposed as the piezo layer in the piezo fan structure. The novel solution can offer large air flow rate and low power consumption. Since the operating frequency is beyond the human audible frequencies, non?audible noise fans are expected by using the proposed ultrasonic piezo fan system. Moreover, fabrication of these ultrasonic piezo fans can be part of the GPU fabrication process itself.

  15. Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity: A Pilot Study.

    PubMed

    Ardic, Fusun; Göcer, Esra

    2016-03-01

    The purpose of this study was to examine the monitoring capabilities of the equipment for clever exercise pedometer (ECE PEDO) that provides audible feedback when the person exceeds the upper and lower limits of the target step numbers per minute and to compare step counts with Yamax SW-200 (YX200) as the criterion pedometer.A total of 30 adult volunteers (15 males and 15 females) were classified as normal weight (n = 10), overweight (n = 10), and obese (n = 10). After the submaximal exercise test on a treadmill, the moderate intensity for walking was determined by using YX200 pedometer and then the number of steps taken in a minute was measured. Lower and upper limits of steps per minute (cadence) were recorded in ECE PEDO providing audible feedback when the person's walking speed gets out of the limits. Volunteers walked for 30 minutes in the individual step count range by attaching the ECE PEDO and YX200 pedometer on both sides of the waist belt in the same session. Step counts of the volunteers were recorded. Wilcoxon, Spearman correlation, and Bland-Altman analyses were performed to show the relationship and agreement between the results of 2 devices.Subjects took an average of 3511 ± 426 and 3493 ± 399 steps during 30 minutes with ECE PEDO and criterion pedometer, respectively. About 3500 steps taken by ECE PEDO reflected that this pedometer has capability of identifying steps per minute to meet moderate intensity of physical activity. There was a strong correlation between step counts of both devices (P < 0.001, r = 0.96). Correlations across all three BMI categories and both sex remained consistently high ranging from 0.92 to 0.95. There was a high level of agreement between the ECE PEDO and YX200 pedometer in the Bland-Altman analysis.Although both devices showed a strong similarity in counting steps, the ECE PEDO provides monitoring of intensity such that a person can walk in a specified time with a desired speed.

  16. Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity

    PubMed Central

    Ardic, Fusun; Göcer, Esra

    2016-01-01

    Abstract The purpose of this study was to examine the monitoring capabilities of the equipment for clever exercise pedometer (ECE PEDO) that provides audible feedback when the person exceeds the upper and lower limits of the target step numbers per minute and to compare step counts with Yamax SW-200 (YX200) as the criterion pedometer. A total of 30 adult volunteers (15 males and 15 females) were classified as normal weight (n = 10), overweight (n = 10), and obese (n = 10). After the submaximal exercise test on a treadmill, the moderate intensity for walking was determined by using YX200 pedometer and then the number of steps taken in a minute was measured. Lower and upper limits of steps per minute (cadence) were recorded in ECE PEDO providing audible feedback when the person's walking speed gets out of the limits. Volunteers walked for 30 minutes in the individual step count range by attaching the ECE PEDO and YX200 pedometer on both sides of the waist belt in the same session. Step counts of the volunteers were recorded. Wilcoxon, Spearman correlation, and Bland–Altman analyses were performed to show the relationship and agreement between the results of 2 devices. Subjects took an average of 3511 ± 426 and 3493 ± 399 steps during 30 minutes with ECE PEDO and criterion pedometer, respectively. About 3500 steps taken by ECE PEDO reflected that this pedometer has capability of identifying steps per minute to meet moderate intensity of physical activity. There was a strong correlation between step counts of both devices (P < 0.001, r = 0.96). Correlations across all three BMI categories and both sex remained consistently high ranging from 0.92 to 0.95. There was a high level of agreement between the ECE PEDO and YX200 pedometer in the Bland–Altman analysis. Although both devices showed a strong similarity in counting steps, the ECE PEDO provides monitoring of intensity such that a person can walk in a specified time with a desired speed. PMID:26962822

  17. 30 CFR 75.1600-2 - Communication facilities; working sections; installation and maintenance requirements; audible or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., however, that where trolley phones and telephones are both used, an alternate source of power for the trolley phone system is not required. (d) Trolley phones connected to the trolley wire shall be grounded...

  18. Strength and Dislocation Structure Evolution of Small Metals under Vibrations

    NASA Astrophysics Data System (ADS)

    Ngan, Alfonso

    2015-03-01

    It is well-known that ultrasonic vibration can soften metals, and this phenomenon has been widely exploited in industrial applications concerning metal forming and bonding. In this work, we explore the effects of a superimposed small oscillatory load on metal plasticity, from the nano- to macro-size range, and from audible to ultrasonic frequency ranges. Macroscopic and nano-indentation were performed on aluminum, copper and molybdenum, and the results show that the simultaneous application of oscillatory stresses can lower the hardness of these samples. More interestingly, EBSD and TEM observations show that subgrain formation and reduction in dislocation density generally occurred when stress oscillations were applied. These findings point to an important knowledge gap in metal plasticity - the existing understanding of ultrasound softening in terms of the vibrations either imposing additional stress waves to augment the quasi-static applied load, or heating up the metal, whereas the metal's intrinsic deformation resistance or dislocation interactive processes are assumed unaltered by the ultrasound, is proven wrong by the present results. Furthermore, in the case of nanoindentation, the Continuous Stiffness Measurement technique for contact stiffness measurement assumes that the imposed signal-carrier oscillations do not intrinsically alter the material properties of the specimen, and again, the present results prove that this can be wrong. To understand the enhanced subgrain formation and dislocation annihilation, Discrete Dislocation Dynamics (DDD) simulations were carried out and these show that when an oscillatory stress is superimposed on a quasi-static applied stress, reversals of motion of dislocations may occur, and these allow the dislocations to revisit repeatedly suitable configurations for annihilation. DDD, however, was unable to predict the observed subgrain formation presumably because the number of dislocations that can be handled is not large enough. Subgrain formation was directly predicted by a new simulation method of dislocation plasticity based on the dynamics of dislocation density functions.

  19. The effect of instantaneous input dynamic range setting on the speech perception of children with the nucleus 24 implant.

    PubMed

    Davidson, Lisa S; Skinner, Margaret W; Holstad, Beth A; Fears, Beverly T; Richter, Marie K; Matusofsky, Margaret; Brenner, Christine; Holden, Timothy; Birath, Amy; Kettel, Jerrica L; Scollie, Susan

    2009-06-01

    The purpose of this study was to examine the effects of a wider instantaneous input dynamic range (IIDR) setting on speech perception and comfort in quiet and noise for children wearing the Nucleus 24 implant system and the Freedom speech processor. In addition, children's ability to understand soft and conversational level speech in relation to aided sound-field thresholds was examined. Thirty children (age, 7 to 17 years) with the Nucleus 24 cochlear implant system and the Freedom speech processor with two different IIDR settings (30 versus 40 dB) were tested on the Consonant Nucleus Consonant (CNC) word test at 50 and 60 dB SPL, the Bamford-Kowal-Bench Speech in Noise Test, and a loudness rating task for four-talker speech noise. Aided thresholds for frequency-modulated tones, narrowband noise, and recorded Ling sounds were obtained with the two IIDRs and examined in relation to CNC scores at 50 dB SPL. Speech Intelligibility Indices were calculated using the long-term average speech spectrum of the CNC words at 50 dB SPL measured at each test site and aided thresholds. Group mean CNC scores at 50 dB SPL with the 40 IIDR were significantly higher (p < 0.001) than with the 30 IIDR. Group mean CNC scores at 60 dB SPL, loudness ratings, and the signal to noise ratios-50 for Bamford-Kowal-Bench Speech in Noise Test were not significantly different for the two IIDRs. Significantly improved aided thresholds at 250 to 6000 Hz as well as higher Speech Intelligibility Indices afforded improved audibility for speech presented at soft levels (50 dB SPL). These results indicate that an increased IIDR provides improved word recognition for soft levels of speech without compromising comfort of higher levels of speech sounds or sentence recognition in noise.

  20. Audible monitor for electroplating

    NASA Technical Reports Server (NTRS)

    Burowick, E. A.

    1979-01-01

    "No buzzer" indicates early problem in electroplating when parts are properly immersed into electropolating bath. Buzzer sounds when current flows through part; however, if current is cut, buzzer stops warning that parts must be removed and refinished thus preventing unnecessary waste of electrical energy and labor.

  1. [Study on the disabilities in aged 0-7 years children in Shenzhen, China].

    PubMed

    Sun, Xi-bin; Qu, Cheng-yi; Yang, Lei; Yan, Jia-mu; Xie, Jian-wen; Chen, Yi-qing; Long, Mo; Liang, Wei; Li, Su-pei; Gao, Shou-yan; Yin, Dong-yi; Zhou, Wen-pei; Shi, Shuai; Hua, Fang; Zhou, Ben-li; Zhu, Shao-ming; Wang, Li; Feng, Dai-hao; Zhou, Lin

    2003-11-01

    To explore the prevalence of vision, mental, audibility, language, psychiatry, extremity, and influence factors in the 0 - 7 year olds. A total number of 77,727 0 - 7 year old children living in Shenzhen city were tested with tree phase screening under the Chinese standard of evaluation in disabilities. The prevalence of all disabilities was 5.59 per thousand (adjusted rate was 8.49 per thousand with a false negative of 3.1 per thousand ). The prevalence of mental disease was the highest (1.88 per thousand, with adjusted rate 3.43 per thousand ), the prevalence of language disability was 1.88 per thousand (including retarded language development, with adjusted rate 3.43 per thousand ). The prevalence rates of psychiatry, extremity and audibility disability were 1.59 per thousand, 1.56 per thousand, 1.11 per thousand respectively with of vision the lowest (0.37 per thousand ). The prevalence of all disabilities, audibility, language and mental was on the increase with age. The difference was statistically significant. Among all different age groups regarding psychiatric disease, the highest fell in the 2 - 4 year olds. The prevalence of extremity was not statistically different among age groups. The suspected agents of disease which occurred before or during pregnancy took up 45.7%. The prevalence of six kinds disabilities in Shenzhen was about 10 per thousand lower than that of the samples of the nation in 1989, but two times higher than that of similar studies in Japan. The prevalence rates of language and psychiatric disease were higher than that of the nation in 1989. The causation should be further studied.

  2. Spontaneous obliteration of spontaneous vertebral arteriovenous fistula associated with fibromuscular dysplasia after partial surgery: A case report.

    PubMed

    Iampreechakul, Prasert; Siriwimonmas, Somkiet

    2016-12-01

    We describe a patient with spontaneous obliteration of spontaneous vertebral arteriovenous fistula (VAVF) associated with fibromuscular dysplasia (FMD) after partial surgery. A 52-year-old hypertensive female woke up one morning with left shoulder pain and weakness of the left upper extremity. A few days later, she developed left-sided audible bruit. She was treated for left frozen shoulder and supportive treatment for audible bruit for four years. She was referred from her general physician to a neurosurgeon because of left arm weakness. Physical examination showed signs of cervical radiculomyelopathy. Magnetic resonance imaging (MRI) showed an extradural mass on the left side of the cervical spinal canal from level C2 to C6. Provisional diagnosis was epidural vascular tumour. Laminectomy and partial removal of the mass was performed at level C5 to C6. Pathological report revealed suspected vascular malformation. Postoperative MRI showed thrombosed epidural vascular structure. Angiography showed dysplastic changes of both vertebral arteries representing FMD with VAVF of the left vertebral artery at level C1-C2. Two years after surgery, follow-up MRI demonstrated complete spontaneous resolution of the large thrombosed epidural vein. Disappearance of her audible bruit immediately after surgery and gradual improvement of her cervical radiculomyelopathy were observed after two years of clinical follow-up. From the literature, we found another 11 patients with 12 VAVFs who had spontaneous obliteration or cure of their fistulas. In the present case, spontaneous obliteration of the fistula seems to correlate with surgery inducing closure of the epidural venous exit leading to thrombosis of the enlarged epidural draining vein. © The Author(s) 2016.

  3. Responses of the ear to low frequency sounds, infrasound and wind turbines

    PubMed Central

    Salt, Alec N.; Hullar, Timothy E.

    2010-01-01

    Infrasonic sounds are generated internally in the body (by respiration, heartbeat, coughing, etc) and by external sources, such as air conditioning systems, inside vehicles, some industrial processes and, now becoming increasingly prevalent, wind turbines. It is widely assumed that infrasound presented at an amplitude below what is audible has no influence on the ear. In this review, we consider possible ways that low frequency sounds, at levels that may or may not be heard, could influence the function of the ear. The inner ear has elaborate mechanisms to attenuate low frequency sound components before they are transmitted to the brain. The auditory portion of the ear, the cochlea, has two types of sensory cells, inner hair cells (IHC) and outer hair cells (OHC), of which the IHC are coupled to the afferent fibers that transmit “hearing” to the brain. The sensory stereocilia (“hairs”) on the IHC are “fluid coupled” to mechanical stimuli, so their responses depend on stimulus velocity and their sensitivity decreases as sound frequency is lowered. In contrast, the OHC are directly coupled to mechanical stimuli, so their input remains greater than for IHC at low frequencies. At very low frequencies the OHC are stimulated by sounds at levels below those that are heard. Although the hair cells in other sensory structures such as the saccule may be tuned to infrasonic frequencies, auditory stimulus coupling to these structures is inefficient so that they are unlikely to be influenced by airborne infrasound. Structures that are involved in endolymph volume regulation are also known to be influenced by infrasound, but their sensitivity is also thought to be low. There are, however, abnormal states in which the ear becomes hypersensitive to infrasound. In most cases, the inner ear’s responses to infrasound can be considered normal, but they could be associated with unfamiliar sensations or subtle changes in physiology. This raises the possibility that exposure to the infrasound component of wind turbine noise could influence the physiology of the ear. PMID:20561575

  4. Responses of the ear to low frequency sounds, infrasound and wind turbines.

    PubMed

    Salt, Alec N; Hullar, Timothy E

    2010-09-01

    Infrasonic sounds are generated internally in the body (by respiration, heartbeat, coughing, etc) and by external sources, such as air conditioning systems, inside vehicles, some industrial processes and, now becoming increasingly prevalent, wind turbines. It is widely assumed that infrasound presented at an amplitude below what is audible has no influence on the ear. In this review, we consider possible ways that low frequency sounds, at levels that may or may not be heard, could influence the function of the ear. The inner ear has elaborate mechanisms to attenuate low frequency sound components before they are transmitted to the brain. The auditory portion of the ear, the cochlea, has two types of sensory cells, inner hair cells (IHC) and outer hair cells (OHC), of which the IHC are coupled to the afferent fibers that transmit "hearing" to the brain. The sensory stereocilia ("hairs") on the IHC are "fluid coupled" to mechanical stimuli, so their responses depend on stimulus velocity and their sensitivity decreases as sound frequency is lowered. In contrast, the OHC are directly coupled to mechanical stimuli, so their input remains greater than for IHC at low frequencies. At very low frequencies the OHC are stimulated by sounds at levels below those that are heard. Although the hair cells in other sensory structures such as the saccule may be tuned to infrasonic frequencies, auditory stimulus coupling to these structures is inefficient so that they are unlikely to be influenced by airborne infrasound. Structures that are involved in endolymph volume regulation are also known to be influenced by infrasound, but their sensitivity is also thought to be low. There are, however, abnormal states in which the ear becomes hypersensitive to infrasound. In most cases, the inner ear's responses to infrasound can be considered normal, but they could be associated with unfamiliar sensations or subtle changes in physiology. This raises the possibility that exposure to the infrasound component of wind turbine noise could influence the physiology of the ear. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  5. A correlational method to concurrently measure envelope and temporal fine structure weights: Effects of age, cochlear pathology, and spectral shaping1

    PubMed Central

    Fogerty, Daniel; Humes, Larry E.

    2012-01-01

    The speech signal may be divided into spectral frequency-bands, each band containing temporal properties of the envelope and fine structure. This study measured the perceptual weights for the envelope and fine structure in each of three frequency bands for sentence materials in young normal-hearing listeners, older normal-hearing listeners, aided older hearing-impaired listeners, and spectrally matched young normal-hearing listeners. The availability of each acoustic property was independently varied through noisy signal extraction. Thus, the full speech stimulus was presented with noise used to mask six different auditory channels. Perceptual weights were determined by correlating a listener’s performance with the signal-to-noise ratio of each acoustic property on a trial-by-trial basis. Results demonstrate that temporal fine structure perceptual weights remain stable across the four listener groups. However, a different weighting typography was observed across the listener groups for envelope cues. Results suggest that spectral shaping used to preserve the audibility of the speech stimulus may alter the allocation of perceptual resources. The relative perceptual weighting of envelope cues may also change with age. Concurrent testing of sentences repeated once on a previous day demonstrated that weighting strategies for all listener groups can change, suggesting an initial stabilization period or susceptibility to auditory training. PMID:22978896

  6. Investigation Of Aeroacoustic Mechanisms By Remote Thermal Imaging

    NASA Astrophysics Data System (ADS)

    Witten, Alan J.; Courville, George E.

    1988-01-01

    A hush house is a hangar-like structure designed to isolate, from the surrounding environment, the noise produced by extended aircraft engine operations during diagnostic testing. While hush houses meet this intended need by suppressing audible noise, they do emit significant subaudible acoustic energy which has caused structural vibrations in nearby facilities. As a first step in mitigating the problems associated with hush house induced vibrations, it is necessary to identify the mechanism responsible for the low frequency acoustic emissions. It was hypothesized that the low frequency acoustic waves are a result of acoustic Cherenkov radiation. This radiation is in the form of a coherent wave produced by the engine exhaust gas flow. The speed of sound in the exhaust gas is quite high as a result of its elevated temperature. Therefore, the gas flow is sonic or subsonic relative to its own sound speed, but is supersonic relative to sound speed in the surrounding cooler air and, as a result, produces acoustic Cherenkov radiation. To confirm this hypothesis, thermographic surveys were conducted to image the thermal structure of the engine exhaust gas within the hush house. In the near-field, these images revealed that the exhaust gases did not behave like a high Reynolds number turbulent jet, but rather, the transition to turbulence is delayed by a suppression in growth of the self-excited instability wave as a result of acoustic Cherenkov radiation.

  7. The Influence of Cochlear Mechanical Dysfunction, Temporal Processing Deficits, and Age on the Intelligibility of Audible Speech in Noise for Hearing-Impaired Listeners

    PubMed Central

    Johannesen, Peter T.; Pérez-González, Patricia; Kalluri, Sridhar; Blanco, José L.

    2016-01-01

    The aim of this study was to assess the relative importance of cochlear mechanical dysfunction, temporal processing deficits, and age on the ability of hearing-impaired listeners to understand speech in noisy backgrounds. Sixty-eight listeners took part in the study. They were provided with linear, frequency-specific amplification to compensate for their audiometric losses, and intelligibility was assessed for speech-shaped noise (SSN) and a time-reversed two-talker masker (R2TM). Behavioral estimates of cochlear gain loss and residual compression were available from a previous study and were used as indicators of cochlear mechanical dysfunction. Temporal processing abilities were assessed using frequency modulation detection thresholds. Age, audiometric thresholds, and the difference between audiometric threshold and cochlear gain loss were also included in the analyses. Stepwise multiple linear regression models were used to assess the relative importance of the various factors for intelligibility. Results showed that (a) cochlear gain loss was unrelated to intelligibility, (b) residual cochlear compression was related to intelligibility in SSN but not in a R2TM, (c) temporal processing was strongly related to intelligibility in a R2TM and much less so in SSN, and (d) age per se impaired intelligibility. In summary, all factors affected intelligibility, but their relative importance varied across maskers. PMID:27604779

  8. Study of tonotopic brain changes with functional MRI and FDG-PET in a patient with unilateral objective cochlear tinnitus.

    PubMed

    Guinchard, A-C; Ghazaleh, Naghmeh; Saenz, M; Fornari, E; Prior, J O; Maeder, P; Adib, S; Maire, R

    2016-11-01

    We studied possible brain changes with functional MRI (fMRI) and fluorodeoxyglucose positron emission tomography (FDG-PET) in a patient with a rare, high-intensity "objective tinnitus" (high-level SOAEs) in the left ear of 10 years duration, with no associated hearing loss. This is the first case of objective cochlear tinnitus to be investigated with functional neuroimaging. The objective cochlear tinnitus was measured by Spontaneous Otoacoustic Emissions (SOAE) equipment (frequency 9689 Hz, intensity 57 dB SPL) and is clearly audible to anyone standing near the patient. Functional modifications in primary auditory areas and other brain regions were evaluated using 3T and 7T fMRI and FDG-PET. In the fMRI evaluations, a saturation of the auditory cortex at the tinnitus frequency was observed, but the global cortical tonotopic organization remained intact when compared to the results of fMRI of healthy subjects. The FDG-PET showed no evidence of an increase or decrease of activity in the auditory cortices or in the limbic system as compared to normal subjects. In this patient with high-intensity objective cochlear tinnitus, fMRI and FDG-PET showed no significant brain reorganization in auditory areas and/or in the limbic system, as reported in the literature in patients with chronic subjective tinnitus. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. The marine soundscape of the Perth Canyon

    NASA Astrophysics Data System (ADS)

    Erbe, Christine; Verma, Arti; McCauley, Robert; Gavrilov, Alexander; Parnum, Iain

    2015-09-01

    The Perth Canyon is a submarine canyon off Rottnest Island in Western Australia. It is rich in biodiversity in general, and important as a feeding and resting ground for great whales on migration. Australia's Integrated Marine Observing System (IMOS) has moorings in the Perth Canyon monitoring its acoustical, physical and biological oceanography. Data from these moorings, as well as weather data from a near-by Bureau of Meteorology weather station on Rottnest Island and ship traffic data from the Australian Maritime Safety Authority were correlated to characterise and quantify the marine soundscape between 5 and 3000 Hz, consisting of its geophony, biophony and anthrophony. Overall, biological sources are a strong contributor to the soundscape at the IMOS site, with whales dominating seasonally at low (15-100 Hz) and mid frequencies (200-400 Hz), and fish or invertebrate choruses dominating at high frequencies (1800-2500 Hz) at night time throughout the year. Ships contribute significantly to the 8-100 Hz band at all times of the day, all year round, albeit for a few hours at a time only. Wind-dependent noise is significant at 200-3000 Hz; winter rains are audible underwater at 2000-3000 Hz. We discuss how passive acoustic data can be used as a proxy for ocean weather. Passive acoustics is an efficient way of monitoring animal visitation times and relative densities, and potential anthropogenic influences.

  10. 46 CFR 63.15-7 - Alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...

  11. 46 CFR 63.15-7 - Alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...

  12. 46 CFR 63.15-7 - Alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...

  13. 46 CFR 63.15-7 - Alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...

  14. 46 CFR 63.15-7 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General Requirements § 63.15-7 Alarms. (a) An audible alarm must automatically sound when a flame safety system shutdown occurs. A visible indicator must indicate that the shutdown was caused by the flame safety system...

  15. 40 CFR 65.143 - Closed vent systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... storage vessel, process vent, transfer rack, or equipment leaks. (1) Collection of emissions. Each closed... material from a storage vessel, transfer rack or equipment leaks. Inspection records shall be generated as... (B) Conduct annual visual inspections for visible, audible, or olfactory indications of leaks. (ii...

  16. 75 FR 34486 - Petitions for Modification

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-17

    ... while continuously monitoring for methane levels. Immediately prior to the use of the non-permissible equipment, the mine atmosphere will be tested for methane within 6 inches, and would be continuously monitored with an approved instrument capable of providing both visual and audible alarms. Methane levels...

  17. 46 CFR 151.40-10 - Operational requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... shall operate when either the pressure or the temperature exceeds the operating limits of the system... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES... Operational requirements. Control systems, required by Table 151.05 shall be provided with an audible or...

  18. Analysis of modeling cumulative noise from simultaneous flights volume 2 : supplemental analysis

    DOT National Transportation Integrated Search

    2012-12-31

    This is the second of two volumes of the report on modeling cumulative noise from simultaneous flights. This volume examines the effect of several modeling input cases on Percent Time Audible results calculated by the Integrated Noise Model. The case...

  19. 29 CFR 1926.555 - Conveyors.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Helicopters, Hoists, Elevators, and Conveyors § 1926.555... operator's station. Conveyor systems shall be equipped with an audible warning signal to be sounded... tagged out with a “Do Not Operate” tag during repairs and when operation is hazardous to employees...

  20. 29 CFR 1926.555 - Conveyors.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Helicopters, Hoists, Elevators, and Conveyors § 1926.555... operator's station. Conveyor systems shall be equipped with an audible warning signal to be sounded... tagged out with a “Do Not Operate” tag during repairs and when operation is hazardous to employees...

  1. 29 CFR 1926.555 - Conveyors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Helicopters, Hoists, Elevators, and Conveyors § 1926.555... operator's station. Conveyor systems shall be equipped with an audible warning signal to be sounded... tagged out with a “Do Not Operate” tag during repairs and when operation is hazardous to employees...

  2. 29 CFR 1926.555 - Conveyors.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Helicopters, Hoists, Elevators, and Conveyors § 1926.555... operator's station. Conveyor systems shall be equipped with an audible warning signal to be sounded... tagged out with a “Do Not Operate” tag during repairs and when operation is hazardous to employees...

  3. 10 CFR 70.24 - Criticality accident requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Criticality accident requirements. 70.24 Section 70.24... Applications § 70.24 Criticality accident requirements. (a) Each licensee authorized to possess special nuclear...-sensitive radiation detectors which will energize clearly audible alarm signals if accidental criticality...

  4. 10 CFR 70.24 - Criticality accident requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Criticality accident requirements. 70.24 Section 70.24... Applications § 70.24 Criticality accident requirements. (a) Each licensee authorized to possess special nuclear...-sensitive radiation detectors which will energize clearly audible alarm signals if accidental criticality...

  5. 10 CFR 70.24 - Criticality accident requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Criticality accident requirements. 70.24 Section 70.24... Applications § 70.24 Criticality accident requirements. (a) Each licensee authorized to possess special nuclear...-sensitive radiation detectors which will energize clearly audible alarm signals if accidental criticality...

  6. 10 CFR 70.24 - Criticality accident requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Criticality accident requirements. 70.24 Section 70.24... Applications § 70.24 Criticality accident requirements. (a) Each licensee authorized to possess special nuclear...-sensitive radiation detectors which will energize clearly audible alarm signals if accidental criticality...

  7. 10 CFR 70.24 - Criticality accident requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Criticality accident requirements. 70.24 Section 70.24... Applications § 70.24 Criticality accident requirements. (a) Each licensee authorized to possess special nuclear...-sensitive radiation detectors which will energize clearly audible alarm signals if accidental criticality...

  8. Concealed wire tracing apparatus

    DOEpatents

    Kronberg, J.W.

    1994-05-31

    An apparatus and method that combines a signal generator and a passive signal receiver to detect and record the path of partially or completely concealed electrical wiring without disturbing the concealing surface is disclosed. The signal generator applies a series of electrical pulses to the selected wiring of interest. The applied pulses create a magnetic field about the wiring that can be detected by a coil contained within the signal receiver. An audible output connected to the receiver and driven by the coil reflects the receivers position with respect to the wiring. The receivers audible signal is strongest when the receiver is directly above the wiring and the long axis of the receivers coil is parallel to the wiring. A marking means is mounted on the receiver to mark the location of the wiring as the receiver is directed over the wiring's concealing surface. Numerous marks made on various locations of the concealing surface will trace the path of the wiring of interest. 4 figs.

  9. Unvoiced Speech Recognition Using Tissue-Conductive Acoustic Sensor

    NASA Astrophysics Data System (ADS)

    Heracleous, Panikos; Kaino, Tomomi; Saruwatari, Hiroshi; Shikano, Kiyohiro

    2006-12-01

    We present the use of stethoscope and silicon NAM (nonaudible murmur) microphones in automatic speech recognition. NAM microphones are special acoustic sensors, which are attached behind the talker's ear and can capture not only normal (audible) speech, but also very quietly uttered speech (nonaudible murmur). As a result, NAM microphones can be applied in automatic speech recognition systems when privacy is desired in human-machine communication. Moreover, NAM microphones show robustness against noise and they might be used in special systems (speech recognition, speech transform, etc.) for sound-impaired people. Using adaptation techniques and a small amount of training data, we achieved for a 20 k dictation task a[InlineEquation not available: see fulltext.] word accuracy for nonaudible murmur recognition in a clean environment. In this paper, we also investigate nonaudible murmur recognition in noisy environments and the effect of the Lombard reflex on nonaudible murmur recognition. We also propose three methods to integrate audible speech and nonaudible murmur recognition using a stethoscope NAM microphone with very promising results.

  10. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    PubMed

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p < 0.0001. The stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  11. Interactive physically-based sound simulation

    NASA Astrophysics Data System (ADS)

    Raghuvanshi, Nikunj

    The realization of interactive, immersive virtual worlds requires the ability to present a realistic audio experience that convincingly compliments their visual rendering. Physical simulation is a natural way to achieve such realism, enabling deeply immersive virtual worlds. However, physically-based sound simulation is very computationally expensive owing to the high-frequency, transient oscillations underlying audible sounds. The increasing computational power of desktop computers has served to reduce the gap between required and available computation, and it has become possible to bridge this gap further by using a combination of algorithmic improvements that exploit the physical, as well as perceptual properties of audible sounds. My thesis is a step in this direction. My dissertation concentrates on developing real-time techniques for both sub-problems of sound simulation: synthesis and propagation. Sound synthesis is concerned with generating the sounds produced by objects due to elastic surface vibrations upon interaction with the environment, such as collisions. I present novel techniques that exploit human auditory perception to simulate scenes with hundreds of sounding objects undergoing impact and rolling in real time. Sound propagation is the complementary problem of modeling the high-order scattering and diffraction of sound in an environment as it travels from source to listener. I discuss my work on a novel numerical acoustic simulator (ARD) that is hundred times faster and consumes ten times less memory than a high-accuracy finite-difference technique, allowing acoustic simulations on previously-intractable spaces, such as a cathedral, on a desktop computer. Lastly, I present my work on interactive sound propagation that leverages my ARD simulator to render the acoustics of arbitrary static scenes for multiple moving sources and listener in real time, while accounting for scene-dependent effects such as low-pass filtering and smooth attenuation behind obstructions, reverberation, scattering from complex geometry and sound focusing. This is enabled by a novel compact representation that takes a thousand times less memory than a direct scheme, thus reducing memory footprints to fit within available main memory. To the best of my knowledge, this is the only technique and system in existence to demonstrate auralization of physical wave-based effects in real-time on large, complex 3D scenes.

  12. Language (In)competency, Communication Strategies, and the Development of an International Academic Teacher Identity: Becoming an Audible Minority

    ERIC Educational Resources Information Center

    McAllum, Kirstie

    2017-01-01

    Despite universities' enthusiasm for internationalization, international academic mobility requires considerable institutional and cultural adjustment in terms of teaching and supervision styles, research expectations, and departmental relationships. Although language competency underpins these practices, research on international academics has…

  13. NOAA Weather Radio

    Science.gov Websites

    Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME does not make an audible beep. However, it will display the words "CHECK RECEPTION" until it Reception Problems General Information NWR Alarms FIPS Codes Automated Voices Spanish Voices Public

  14. 46 CFR 95.15-30 - Alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... automatically and audibly for at least 20 seconds before carbon dioxide is discharged into the space; (2) Be..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) A protected space must be fitted with an...

  15. Chicanos y Chicanas Prominentes.

    ERIC Educational Resources Information Center

    Wood, Theodore E. B.

    A sequel to "A Portfolio of Outstanding Americans of Mexican Descent", this portfolio contains 24 portraits and biographical sketches in both English and Spanish of Mexican American personalities who have become familiar as emergent figures in various sectors of public life. Featured are several women who have made themselves audible as…

  16. 46 CFR 154.1340 - Temperature measuring devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Each device must actuate an audible and visual alarm at the cargo control station and a remote group... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment... cargo control station. (c) Except for independent tanks type C, each cargo containment system for a...

  17. 46 CFR 154.1340 - Temperature measuring devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Each device must actuate an audible and visual alarm at the cargo control station and a remote group... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment... cargo control station. (c) Except for independent tanks type C, each cargo containment system for a...

  18. 46 CFR 154.1340 - Temperature measuring devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Each device must actuate an audible and visual alarm at the cargo control station and a remote group... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment... cargo control station. (c) Except for independent tanks type C, each cargo containment system for a...

  19. 46 CFR 154.1340 - Temperature measuring devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Each device must actuate an audible and visual alarm at the cargo control station and a remote group... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment... cargo control station. (c) Except for independent tanks type C, each cargo containment system for a...

  20. 46 CFR 154.1340 - Temperature measuring devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Each device must actuate an audible and visual alarm at the cargo control station and a remote group... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment... cargo control station. (c) Except for independent tanks type C, each cargo containment system for a...

  1. 16 CFR 1210.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... which this regulation applies. (d) Novelty lighter means a lighter that has entertaining audio or visual effects, or that depicts (logos, decals, art work, etc.) or resembles in physical form or function... produce a flame; and produces an audible or visual signal that will be clearly discernible when the...

  2. 30 CFR 57.14214 - Train warnings.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Train warnings. 57.14214 Section 57.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Equipment Safety Practices and Operational Procedures § 57.14214 Train warnings. A warning that is audible...

  3. 30 CFR 56.14214 - Train warnings.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Train warnings. 56.14214 Section 56.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Safety Practices and Operational Procedures § 56.14214 Train warnings. A warning that is audible above...

  4. 30 CFR 56.14214 - Train warnings.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Train warnings. 56.14214 Section 56.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Safety Practices and Operational Procedures § 56.14214 Train warnings. A warning that is audible above...

  5. 30 CFR 56.14214 - Train warnings.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Train warnings. 56.14214 Section 56.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Safety Practices and Operational Procedures § 56.14214 Train warnings. A warning that is audible above...

  6. 30 CFR 56.14214 - Train warnings.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Train warnings. 56.14214 Section 56.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Safety Practices and Operational Procedures § 56.14214 Train warnings. A warning that is audible above...

  7. 30 CFR 56.14214 - Train warnings.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Train warnings. 56.14214 Section 56.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Safety Practices and Operational Procedures § 56.14214 Train warnings. A warning that is audible above...

  8. 30 CFR 57.14214 - Train warnings.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Train warnings. 57.14214 Section 57.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Equipment Safety Practices and Operational Procedures § 57.14214 Train warnings. A warning that is audible...

  9. 30 CFR 57.14214 - Train warnings.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Train warnings. 57.14214 Section 57.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Equipment Safety Practices and Operational Procedures § 57.14214 Train warnings. A warning that is audible...

  10. 30 CFR 57.14214 - Train warnings.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Train warnings. 57.14214 Section 57.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Equipment Safety Practices and Operational Procedures § 57.14214 Train warnings. A warning that is audible...

  11. 30 CFR 57.14214 - Train warnings.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Train warnings. 57.14214 Section 57.14214 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Equipment Safety Practices and Operational Procedures § 57.14214 Train warnings. A warning that is audible...

  12. 30 CFR 18.20 - Quality of material, workmanship, and design.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES... facilitate inspection and maintenance. (b) MSHA will test only electrical equipment that in the opinion of... shall be accessible for field inspection, where practicable. (e) An audible warning device shall be...

  13. 30 CFR 18.20 - Quality of material, workmanship, and design.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES... facilitate inspection and maintenance. (b) MSHA will test only electrical equipment that in the opinion of... shall be accessible for field inspection, where practicable. (e) An audible warning device shall be...

  14. Quieter Cars and the Safety of Blind Pedestrians, Phase 2 : Development of Potential Specifications for Vehicle Countermeasure Sounds.

    DOT National Transportation Integrated Search

    2011-10-01

    This project performed research to support the development of potential specifications for vehicle : sounds, (i.e., audible countermeasures) to be used in vehicles while operating in electric mode in specific low speed : conditions. The purpose of th...

  15. Interaction of a Rectangular Jet with a Flat-Plate Placed Parallel to the Flow

    NASA Technical Reports Server (NTRS)

    Zaman, K. B. M. Q.; Brown, C. A.; Bridges, J. A.

    2013-01-01

    An experimental study is carried out addressing the flowfield and radiated noise from the interaction of a large aspect ratio rectangular jet with a flat plate placed parallel to but away from the direct path of the jet. Sound pressure level spectra exhibit an increase in the noise levels for both the 'reflected' and 'shielded' sides of the plate relative to the free-jet case. Detailed cross-sectional distributions of flowfield properties obtained by hot-wire anemometry are documented for a low subsonic condition. Corresponding mean Mach number distributions obtained by Pitot-probe surveys are presented for high subsonic conditions. In the latter flow regime and for certain relative locations of the plate, a flow resonance accompanied by audible tones is encountered. Under the resonant condition the jet cross-section experiences an 'axis-switching' and flow visualization indicates the presence of an organized 'vortex street'. The trends of the resonant frequency variation with flow parameters exhibit some similarities to, but also marked differences with, corresponding trends of the well-known edgetone phenomenon.

  16. Sound, infrasound, and sonic boom absorption by atmospheric clouds.

    PubMed

    Baudoin, Michaël; Coulouvrat, François; Thomas, Jean-Louis

    2011-09-01

    This study quantifies the influence of atmospheric clouds on propagation of sound and infrasound, based on an existing model [Gubaidulin and Nigmatulin, Int. J. Multiphase Flow 26, 207-228 (2000)]. Clouds are considered as a dilute and polydisperse suspension of liquid water droplets within a mixture of dry air and water vapor, both considered as perfect gases. The model is limited to low and medium altitude clouds, with a small ice content. Four physical mechanisms are taken into account: viscoinertial effects, heat transfer, water phase changes (evaporation and condensation), and vapor diffusion. Physical properties of atmospheric clouds (altitude, thickness, water content and droplet size distribution) are collected, along with values of the thermodynamical coefficients. Different types of clouds have been selected. Quantitative evaluation shows that, for low audible and infrasound frequencies, absorption within clouds is several orders of magnitude larger than classical absorption. The importance of phase changes and vapor diffusion is outlined. Finally, numerical simulations for nonlinear propagation of sonic booms indicate that, for thick clouds, attenuation can lead to a very large decay of the boom at the ground level. © 2011 Acoustical Society of America

  17. Flexible black phosphorus ambipolar transistors, circuits and AM demodulator.

    PubMed

    Zhu, Weinan; Yogeesh, Maruthi N; Yang, Shixuan; Aldave, Sandra H; Kim, Joon-Seok; Sonde, Sushant; Tao, Li; Lu, Nanshu; Akinwande, Deji

    2015-03-11

    High-mobility two-dimensional (2D) semiconductors are desirable for high-performance mechanically flexible nanoelectronics. In this work, we report the first flexible black phosphorus (BP) field-effect transistors (FETs) with electron and hole mobilities superior to what has been previously achieved with other more studied flexible layered semiconducting transistors such as MoS2 and WSe2. Encapsulated bottom-gated BP ambipolar FETs on flexible polyimide afforded maximum carrier mobility of about 310 cm(2)/V·s with field-effect current modulation exceeding 3 orders of magnitude. The device ambipolar functionality and high-mobility were employed to realize essential circuits of electronic systems for flexible technology including ambipolar digital inverter, frequency doubler, and analog amplifiers featuring voltage gain higher than other reported layered semiconductor flexible amplifiers. In addition, we demonstrate the first flexible BP amplitude-modulated (AM) demodulator, an active stage useful for radio receivers, based on a single ambipolar BP transistor, which results in audible signals when connected to a loudspeaker or earphone. Moreover, the BP transistors feature mechanical robustness up to 2% uniaxial tensile strain and up to 5000 bending cycles.

  18. 12th Anglo-French Physical Acoustics Conference (AFPAC2013)

    NASA Astrophysics Data System (ADS)

    2014-04-01

    The Anglo-French Physical Acoustics Conference (AFPAC) had its 12th annual meeting in Villa Clythia, Fréjus, France, from 16th to 18th January 2013. This series of meetings is a collaboration between the Physical Acoustics Group (PAG) of the Institute of Physics and the Groupe d'Acoustique Physique, Sous-marine et UltraSonore (GAPSUS) of the Société Française d'Acoustique. This year, attendees got the opportunity to see the French Riviera with its Mediterranean vegetation covered by a nice thick snow layer. The participants heard 34 excellent oral presentations and saw 3 posters covering an exciting and diverse range of subjects and of frequencies, from ultrasonic wave propagation in chocolate to metamaterials applied to seismic waves for protecting buildings. Among them, invited talks were given by Pr F A Duck ( Enhanced healing by ultrasound: clinical effects and mechanisms), Pr. J-C Valiére, who actually gave two invited talks ( 1. Measurement of audible acoustic particle velocity using laser: Principles, signal processing and applications, 2. Acoustic pots in ancient and medieval buildings: Literary analysis of ancient texts and comparison with recent observations in French churches), Dr P Huthwaite ( Ultrasonic imaging through the resolution of inverse problems), Dr X Lurton ( Underwater acoustic systems on oceanographic research vessels: principles and applications), Dr S Guenneau ( From platonics to seismic metamaterials). For the fifth consecutive year AFPAC is followed by the publication of its proceedings with 12 peer-reviewed papers which cover the most recent research developments in the field of Physical Acoustics in the UK and France. Alain Lhémery (CEA, France) and Nader Saffari (UCL, United Kingdom) French Riviera 12th AFPAC — Villa Clythia, Fréjus (French Riviera), the 17th of January 2013

  19. Laryngeal evidence for the first and second passaggio in professionally trained sopranos

    PubMed Central

    Burk, Fabian; Köberlein, Marie; Selamtzis, Andreas; Döllinger, Michael; Burdumy, Michael; Richter, Bernhard

    2017-01-01

    Introduction Due to a lack of empirical data, the current understanding of the laryngeal mechanics in the passaggio regions (i.e., the fundamental frequency ranges where vocal registration events usually occur) of the female singing voice is still limited. Material and methods In this study the first and second passaggio regions of 10 professionally trained female classical soprano singers were analyzed. The sopranos performed pitch glides from A3 (ƒo = 220 Hz) to A4 (ƒo = 440 Hz) and from A4 (ƒo = 440 Hz) to A5 (ƒo = 880 Hz) on the vowel [iː]. Vocal fold vibration was assessed with trans-nasal high speed videoendoscopy at 20,000 fps, complemented by simultaneous electroglottographic (EGG) and acoustic recordings. Register breaks were perceptually rated by 12 voice experts. Voice stability was documented with the EGG-based sample entropy. Glottal opening and closing patterns during the passaggi were analyzed, supplemented with open quotient data extracted from the glottal area waveform. Results In both the first and the second passaggio, variations of vocal fold vibration patterns were found. Four distinct patterns emerged: smooth transitions with either increasing or decreasing durations of glottal closure, abrupt register transitions, and intermediate loss of vocal fold contact. Audible register transitions (in both the first and second passaggi) generally coincided with higher sample entropy values and higher open quotient variance through the respective passaggi. Conclusions Noteworthy vocal fold oscillatory registration events occur in both the first and the second passaggio even in professional sopranos. The respective transitions are hypothesized to be caused by either (a) a change of laryngeal biomechanical properties; or by (b) vocal tract resonance effects, constituting level 2 source-filter interactions. PMID:28467509

  20. Data mining of audiology patient records: factors influencing the choice of hearing aid type

    PubMed Central

    2012-01-01

    Background This paper describes the analysis of a database of over 180,000 patient records, collected from over 23,000 patients, by the hearing aid clinic at James Cook University Hospital in Middlesbrough, UK. These records consist of audiograms (graphs of the faintest sounds audible to the patient at six different pitches), categorical data (such as age, gender, diagnosis and hearing aid type) and brief free text notes made by the technicians. This data is mined to determine which factors contribute to the decision to fit a BTE (worn behind the ear) hearing aid as opposed to an ITE (worn in the ear) hearing aid. Methods From PCA (principal component analysis) four main audiogram types are determined, and are related to the type of hearing aid chosen. The effects of age, gender, diagnosis, masker, mould and individual audiogram frequencies are combined into a single model by means of logistic regression. Some significant keywords are also discovered in the free text fields by using the chi-squared (χ2) test, which can also be used in the model. The final model can act a decision support tool to help decide whether an individual patient should be offered a BTE or an ITE hearing aid. Results The final model was tested using 5-fold cross validation, and was able to replicate the decisions of audiologists whether to fit an ITE or a BTE hearing aid with precision in the range 0.79 to 0.87. Conclusions A decision support system was produced to predict the type of hearing aid which should be prescribed, with an explanation facility explaining how that decision was arrived at. This system should prove useful in providing a "second opinion" for audiologists. PMID:22595091

  1. Sports betting marketing during sporting events: a stadium and broadcast census of Australian Football League matches.

    PubMed

    Thomas, Samantha; Lewis, Sophie; Duong, Jenny; McLeod, Colin

    2012-04-01

    Using Australian Football League (AFL) matches as a case study, we investigated the frequency, length and content of marketing strategies for sports betting during two specific settings: 1) at stadiums during four live matches; and 2) during eight televised broadcasts of matches. Census of sports betting marketing during Round 12 of the 2011 AFL premiership season. Per match, there was an average of 58.5 episodes (median 49.5, s.d 27.8) and 341.1 minutes (median 324.1 minutes and s.d 44.5) of sports betting marketing at stadiums, and 50.5 episodes (median 53.5, s.d 45.2) and 4.8 minutes (median 5.0 minutes, s.d 4.0) during televised broadcasts. A diverse range of marketing techniques were used to: a) embed sports betting within the game; b) align sports betting with fans' overall experience of the game; and c) encourage individuals to bet live during the game. There were very few visible or audible messages (such as responsible gambling or Gambler's Help messages) to counter-frame the overwhelmingly positive messages that individuals received about sports betting during the match. This study raises important questions about the impacts of saturation, integrated and impulse gambling marketing strategies in sporting matches. Future research should explore: 1) how wagering industry marketing strategies may affect the attitudes and behaviours of community sub-groups (e.g. young male sports fans, and children); and 2) which public health and policy strategies, including regulation and harm minimisation messaging, will be effective in responding to wagering industry marketing strategies during sporting matches. © 2012 The Authors. ANZJPH © 2012 Public Health Association of Australia.

  2. Treating youths with selective mutism with an alternating design of exposure-based practice and contingency management.

    PubMed

    Vecchio, Jennifer; Kearney, Christopher A

    2009-12-01

    Selective mutism is a severe childhood disorder involving failure to speak in public situations in which speaking is expected. The present study examined 9 youths with selective mutism treated with child-focused, exposure-based practices and parent-focused contingency management via an alternating treatments design. Broadband measures of functioning were employed, but particular focus was made on behavioral assessment of words spoken audibly and daily in public situations. Treatment ranged from 8 to 32 sessions and resulted in positive end-state functioning for 8 of 9 participants. Broader analyses indicated greater effectiveness for exposure-based practice than contingency management. The results support recent case reports of behavioral treatment for this population but in more rigorous fashion. Clinical and research challenges are discussed, including caveats about length and intensity of treatment for this population and need to develop standardized daily measures.

  3. Laboratory Study of the Noticeability and Annoyance of Sounds of Low Signal-to-Noise Ratio

    NASA Technical Reports Server (NTRS)

    Sneddon, Matthew; Howe, Richard; Pearsons, Karl; Fidell, Sanford

    1996-01-01

    This report describes a study of the noticeability and annoyance of intruding noises to test participants who were engaged in a distracting foreground task. Ten test participants read material of their own choosing while seated individually in front of a loudspeaker in an anechoic chamber. One of three specially constructed masking noise environments with limited dynamic range was heard at all times. A laboratory computer produced sounds of aircraft and ground vehicles as heard at varying distances at unpredictable intervals and carefully controlled levels. Test participants were instructed to click a computer mouse at any time that a noise distinct from the background noise environment came to their attention, and then to indicate their degree of annoyance with the noise that they had noticed. The results confirmed that both the noticeability of noise intrusions and their annoyance were closely related to their audibility.

  4. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment... it to be turned off after sounding. For remote group alarms this arrangement must not interrupt the..., except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must have...

  5. 30 CFR 57.14132 - Horns and backup alarms for surface equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14132 Horns and backup alarms for surface equipment. (a) Manually-operated horns or other audible warning devices provided on self-propelled mobile equipment as a safety device shall be maintained in a functional...

  6. AFB's Computerized Travel Aid: Two Years of Research and Development.

    ERIC Educational Resources Information Center

    Uslan, Mark M.; And Others

    1983-01-01

    Progress on the computerized travel aid, an electronic device, using elements of the Polaroid Sonar Camera and a microprocessor, for visually handicapped persons is reviewed, and research on the effectiveness of various models noted. Recommended modifications touch on aspects of mounting, beam shape, and audible outputs. (CL)

  7. 30 CFR 75.344 - Compressors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air course or to the surface and equipped with sensors to monitor for heat and for carbon monoxide or smoke. The sensors shall deenergize power to the compressor, activate a visual and audible alarm located... every 31 days, sensors installed to monitor for carbon monoxide shall be calibrated with a known...

  8. 77 FR 56265 - Proposed Information Collection Submitted to the Office of Management and Budget (OMB); Request...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-12

    ... the second experiment will evaluate the lack of effectiveness in current audible warnings designed to...: Title: Recruitment of human subjects for observational experiments regarding keyless ignition controls... motor vehicle safety standards (FMVSSs). Human factors observational experiments are proposed to support...

  9. The Sounds of Science

    ERIC Educational Resources Information Center

    Grant, Julian

    2017-01-01

    In this article, Julian Grant, a Prep VI class teacher at Bridgewater School, Worsley, Manchester, explores the cross-curricular nature of language in scientific recording and how children can waken an audible science world with words. The ideas that came from what started as an applied vocabulary exercise demonstrated just how many…

  10. 30 CFR 75.344 - Compressors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air course or to the surface and equipped with sensors to monitor for heat and for carbon monoxide or smoke. The sensors shall deenergize power to the compressor, activate a visual and audible alarm located... every 31 days, sensors installed to monitor for carbon monoxide shall be calibrated with a known...

  11. 30 CFR 75.344 - Compressors.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air course or to the surface and equipped with sensors to monitor for heat and for carbon monoxide or smoke. The sensors shall deenergize power to the compressor, activate a visual and audible alarm located... every 31 days, sensors installed to monitor for carbon monoxide shall be calibrated with a known...

  12. 30 CFR 75.344 - Compressors.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air course or to the surface and equipped with sensors to monitor for heat and for carbon monoxide or smoke. The sensors shall deenergize power to the compressor, activate a visual and audible alarm located... every 31 days, sensors installed to monitor for carbon monoxide shall be calibrated with a known...

  13. 30 CFR 75.344 - Compressors.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air course or to the surface and equipped with sensors to monitor for heat and for carbon monoxide or smoke. The sensors shall deenergize power to the compressor, activate a visual and audible alarm located... every 31 days, sensors installed to monitor for carbon monoxide shall be calibrated with a known...

  14. 46 CFR 95.15-30 - Alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) Spaces which are protected by a carbon... audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to... sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and the...

  15. 77 FR 69923 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-21

    ... businesses, while maintaining the safety of an audible warning by ringing the bell. A copy of the petition, as well as any written communications concerning the petition, is available for review online at www... following methods: Web site: http://www.regulations.gov/ . Follow the online instructions for submitting...

  16. 30 CFR 250.1004 - Safety equipment requirements for DOI pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of... a flow safety valve (FSV). (ii) For sulphur operations, incoming pipelines delivering gas to the power plant platform may be equipped with high- and low-pressure sensors (PSHL), which activate audible...

  17. 30 CFR 250.1004 - Safety equipment requirements for DOI pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL... operations, incoming pipelines delivering gas to the power plant platform may be equipped with high- and low-pressure sensors (PSHL), which activate audible and visual alarms in lieu of requirements in paragraph (b...

  18. 46 CFR 28.320 - Fixed gas fire extinguishing systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... only in a normally unoccupied machinery space, paint locker, or space containing flammable liquid... protect more than one space. The quantity of extinguishing agent must be at least sufficient for the... to indicate the discharge of the extinguishing agent; (ii) An audible alarm to sound upon discharge...

  19. 46 CFR 28.320 - Fixed gas fire extinguishing systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... only in a normally unoccupied machinery space, paint locker, or space containing flammable liquid... protect more than one space. The quantity of extinguishing agent must be at least sufficient for the... to indicate the discharge of the extinguishing agent; (ii) An audible alarm to sound upon discharge...

  20. 46 CFR 28.320 - Fixed gas fire extinguishing systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... only in a normally unoccupied machinery space, paint locker, or space containing flammable liquid... protect more than one space. The quantity of extinguishing agent must be at least sufficient for the... to indicate the discharge of the extinguishing agent; (ii) An audible alarm to sound upon discharge...

  1. 16 CFR 1500.17 - Banned hazardous substances.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (including but not limited to cherry bombs, M-80 salutes, silver salutes, and other large firecrackers, aerial bombs, and other fireworks designed to produce audible effects, and including kits and components... rocket), aerial bombs, and devices that may be confused with candy or other foods, such as “dragon eggs...

  2. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20... there is no off position. (5) Automation alarms must be separate and independent of the following: (i... with a means to test audible and visual annunciators; (iv) Provide for normal equipment starting and...

  3. Acoustics in Physical Education Settings: The Learning Roadblock

    ERIC Educational Resources Information Center

    Ryan, Stu; Mendel, Lisa Lucks

    2010-01-01

    Background: The audibility of teachers and peers is an essential factor in determining the academic performance of school children. However, acoustic conditions in most classrooms are less than optimal and have been viewed as "hostile listening environments" that undermine the learning of children in school. While research has shown that…

  4. 46 CFR 184.610 - Public address systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... public address system must be a fixed installation and be audible during normal operating conditions... system operable from the operating station. (d) On a vessel of not more than 19.8 meters (65 feet) in... passengers, a public address system is not required if a public announcement made from operating station...

  5. 33 CFR 146.105 - General alarm system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... manned facility must have a general alarm system. When operated, this system shall be audible in all... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false General alarm system. 146.105 Section 146.105 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  6. 46 CFR 154.1335 - Pressure and vacuum protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... audible and visual alarm at the cargo control station, and a remote group alarm in the wheelhouse. (c) If... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and...) Has remote readouts at the cargo control station. (2) If vacuum protection is required under § 154.804...

  7. 46 CFR 154.1335 - Pressure and vacuum protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... audible and visual alarm at the cargo control station, and a remote group alarm in the wheelhouse. (c) If... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and...) Has remote readouts at the cargo control station. (2) If vacuum protection is required under § 154.804...

  8. 46 CFR 154.1335 - Pressure and vacuum protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... audible and visual alarm at the cargo control station, and a remote group alarm in the wheelhouse. (c) If... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and...) Has remote readouts at the cargo control station. (2) If vacuum protection is required under § 154.804...

  9. 46 CFR 154.1335 - Pressure and vacuum protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... audible and visual alarm at the cargo control station, and a remote group alarm in the wheelhouse. (c) If... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and...) Has remote readouts at the cargo control station. (2) If vacuum protection is required under § 154.804...

  10. 46 CFR 63.25-7 - Exhaust gas boilers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... results in inadequate heat transfer, a high temperature alarm or low flow alarm must be activated. An... insufficient to ensure proper heat transfer. Additionally, an audible alarm must automatically sound, and a... water level, the control system must supply the feed water at a rate sufficient to ensure proper heat...

  11. 46 CFR 63.25-7 - Exhaust gas boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... results in inadequate heat transfer, a high temperature alarm or low flow alarm must be activated. An... insufficient to ensure proper heat transfer. Additionally, an audible alarm must automatically sound, and a... water level, the control system must supply the feed water at a rate sufficient to ensure proper heat...

  12. 30 CFR 57.14200 - Warnings prior to starting or moving equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Warnings prior to starting or moving equipment... NONMETAL MINES Machinery and Equipment Safety Practices and Operational Procedures § 57.14200 Warnings... equipment, equipment operators shall sound a warning that is audible above the surrounding noise level or...

  13. 30 CFR 57.14200 - Warnings prior to starting or moving equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Warnings prior to starting or moving equipment... NONMETAL MINES Machinery and Equipment Safety Practices and Operational Procedures § 57.14200 Warnings... equipment, equipment operators shall sound a warning that is audible above the surrounding noise level or...

  14. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic warning device. 27.23 Section 27.23... Automatic warning device. (a) An automatic warning device shall be suitably constructed for incorporation in... automatic warning device shall include an alarm signal (audible or colored light), which shall be made to...

  15. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic warning device. 27.23 Section 27.23... Automatic warning device. (a) An automatic warning device shall be suitably constructed for incorporation in... automatic warning device shall include an alarm signal (audible or colored light), which shall be made to...

  16. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic warning device. 27.23 Section 27.23... Automatic warning device. (a) An automatic warning device shall be suitably constructed for incorporation in... automatic warning device shall include an alarm signal (audible or colored light), which shall be made to...

  17. 30 CFR 27.23 - Automatic warning device.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic warning device. 27.23 Section 27.23... Automatic warning device. (a) An automatic warning device shall be suitably constructed for incorporation in... automatic warning device shall include an alarm signal (audible or colored light), which shall be made to...

  18. Conceptual apparatus for detecting leaks of nonconductive liquids

    NASA Technical Reports Server (NTRS)

    Walsh, G. D.

    1968-01-01

    Apparatus detects leaks at joints in lines carrying electrically nonconductive liquids. The proposed apparatus could include a panel that would give a visual or audible indication of a leak /to permit manual shutdown/ and/or an electromechanical actuator that would automatically cut off the flow when a leak occurs.

  19. How to Generate Chaos at Home.

    ERIC Educational Resources Information Center

    Smith, Douglas

    1992-01-01

    Describes an electronic circuit that can function as a prototype for chaotic systems. Specific applied voltages produce chaotic signals that can be viewed with an oscilloscope or be made audible with a home stereo system. Provides directions for assembly with typical costs, mathematical basis of chaos theory, and experimental extensions. (JJK)

  20. Automatic patient respiration failure detection system with wireless transmission

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Pope, J. M.

    1968-01-01

    Automatic respiration failure detection system detects respiration failure in patients with a surgically implanted tracheostomy tube, and actuates an audible and/or visual alarm. The system incorporates a miniature radio transmitter so that the patient is unencumbered by wires yet can be monitored from a remote location.

Top