Pilot-optimal augmentation synthesis
NASA Technical Reports Server (NTRS)
Schmidt, D. K.
1978-01-01
An augmentation synthesis method usable in the absence of quantitative handling qualities specifications, and yet explicitly including design objectives based on pilot-rating concepts, is presented. The algorithm involves the unique approach of simultaneously solving for the stability augmentation system (SAS) gains, pilot equalization and pilot rating prediction via optimal control techniques. Simultaneous solution is required in this case since the pilot model (gains, etc.) depends upon the augmented plant dynamics, and the augmentation is obviously not a priori known. Another special feature is the use of the pilot's objective function (from which the pilot model evolves) to design the SAS.
Advanced Control System Increases Helicopter Safety
NASA Technical Reports Server (NTRS)
2008-01-01
With support and funding from a Phase II NASA SBIR project from Ames Research Center, Hoh Aeronautics Inc. (HAI), of Lomita, California, produced HeliSAS, a low-cost, lightweight, attitude-command-attitude-hold stability augmentation system (SAS) for civil helicopters and unmanned aerial vehicles. HeliSAS proved itself in over 160 hours of flight testing and demonstrations in a Robinson R44 Raven helicopter, a commercial helicopter popular with news broadcasting and police operations. Chelton Flight Systems, of Boise, Idaho, negotiated with HAI to develop, market, and manufacture HeliSAS, now available as the Chelton HeliSAS Digital Helicopter Autopilot.
14 CFR Appendix B to Part 29 - Airworthiness Criteria for Helicopter Instrument Flight
Code of Federal Regulations, 2010 CFR
2010-01-01
.... Dynamic stability. (a) Any oscillation having a period of less than 5 seconds must damp to 1/2 amplitude... achieve double amplitude in less than 9 seconds. VII. Stability Augmentation System (SAS) (a) If a SAS is... control system must be considered. In addition— (i) The controllability and maneuverability requirements...
The SAS-3 delayed command system
NASA Technical Reports Server (NTRS)
Hoffman, E. J.
1975-01-01
To meet the requirements arising from the increased complexity of the power, attitude control and telemetry systems, a full redundant high-performance control section with delayed command capability was designed for the Small Astronomy Satellite-3 (SAS-3). The relay command system of SAS-3 is characterized by 56 bystate relay commands, with capability for handling up to 64 commands in future versions. The 'short' data command service of SAS-1 and SAS-2 consisting of shifting 24-bit words to two users was expanded to five users and augmented with a 'long load' data command service (up to 4080 bits) used to program the telemetry system and the delayed command subsystem. The inclusion of a delayed command service ensures a program of up to 30 relay or short data commands to be loaded for execution at designated times. The design and system operation of the SAS-3 command section are analyzed, with special attention given to the delayed command subsystem.
NASA Technical Reports Server (NTRS)
Vomaske, R. F.; Innis, R. C.; Swan, B. E.; Grossmith, S. W.
1978-01-01
The stability, control, and handling qualities of an augmented jet flap STOL airplane are presented. The airplane is an extensively modified de Havilland Buffalo military transport. The modified airplane has two fan-jet engines which provide vectorable thrust and compressed air for the augmentor jet flap and Boundary-Layer Control (BLC). The augmentor and BLC air is cross ducted to minimize asymmetric moments produced when one engine is inoperative. The modifications incorporated in the airplane include a Stability Augmentation System (SAS), a powered elevator, and a powered lateral control system. The test gross weight of the airplane was between 165,000 and 209,000 N (37,000 and 47,000 lb). Stability, control, and handling qualities are presented for the airspeed range of 40 to 180 knots. The lateral-directional handling qualities are considered satisfactory for the normal operating range of 65 to 160 knots airspeed when the SAS is functioning. With the SAS inoperative, poor turn coordination and spiral instability are primary deficiencies contributing to marginal handling qualities in the landing approach. The powered elevator control system enhanced the controllability in pitch, particularly in the landing flare and stall recovery.
Helicopter force-feel and stability augmentation system with parallel servo-actuator
NASA Technical Reports Server (NTRS)
Hoh, Roger H. (Inventor)
2006-01-01
A force-feel system is implemented by mechanically coupling a servo-actuator to and in parallel with a flight control system. The servo-actuator consists of an electric motor, a gearing device, and a clutch. A commanded cockpit-flight-controller position is achieved by pilot actuation of a trim-switch. The position of the cockpit-flight-controller is compared with the commanded position to form a first error which is processed by a shaping function to correlate the first error with a commanded force at the cockpit-flight-controller. The commanded force on the cockpit-flight-controller provides centering forces and improved control feel for the pilot. In an embodiment, the force-feel system is used as the basic element of stability augmentation system (SAS). The SAS provides a stabilization signal that is compared with the commanded position to form a second error signal. The first error is summed with the second error for processing by the shaping function.
B-52 stability augmentation system reliability
NASA Technical Reports Server (NTRS)
Bowling, T. C.; Key, L. W.
1976-01-01
The B-52 SAS (Stability Augmentation System) was developed and retrofitted to nearly 300 aircraft. It actively controls B-52 structural bending, provides improved yaw and pitch damping through sensors and electronic control channels, and puts complete reliance on hydraulic control power for rudder and elevators. The system has experienced over 300,000 flight hours and has exhibited service reliability comparable to the results of the reliability test program. Development experience points out numerous lessons with potential application in the mechanization and development of advanced technology control systems of high reliability.
Augmented reality-assisted skull base surgery.
Cabrilo, I; Sarrafzadeh, A; Bijlenga, P; Landis, B N; Schaller, K
2014-12-01
Neuronavigation is widely considered as a valuable tool during skull base surgery. Advances in neuronavigation technology, with the integration of augmented reality, present advantages over traditional point-based neuronavigation. However, this development has not yet made its way into routine surgical practice, possibly due to a lack of acquaintance with these systems. In this report, we illustrate the usefulness and easy application of augmented reality-based neuronavigation through a case example of a patient with a clivus chordoma. We also demonstrate how augmented reality can help throughout all phases of a skull base procedure, from the verification of neuronavigation accuracy to intraoperative image-guidance. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Stability boundaries for command augmentation systems
NASA Technical Reports Server (NTRS)
Shrivastava, P. C.
1987-01-01
The Stability Augmentation System (SAS) is a special case of the Command Augmentation System (CAS). Control saturation imposes bounds on achievable commands. The state equilibrium depends only on the open loop dynamics and control deflection. The control magnitude to achieve a desired command equilibrium is independent of the feedback gain. A feedback controller provides the desired response, maintains the system equilibrium under disturbances, but it does not affect the equilibrium values of states and control. The saturation boundaries change with commands, but the location of the equilibrium points in the saturated region remains unchanged. Nonzero command vectors yield saturation boundaries that are asymmetric with respect to the state equilibrium. Except for the saddle point case with MCE control law, the stability boundaries change with commands. For the cases of saddle point and unstable nodes, the region of stability decreases with increasing command magnitudes.
Design of a control configured tanker aircraft
NASA Technical Reports Server (NTRS)
Walker, S. A.
1976-01-01
The benefits that accrue from using control configured vehicle (CCV) concepts were examined along with the techniques for applying these concepts to an advanced tanker aircraft design. Reduced static stability (RSS) and flutter mode control (FMC) were the two primary CCV concepts used in the design. The CCV tanker was designed to the same mission requirements specified for a conventional tanker design. A seven degree of freedom mathematical model of the flexible aircraft was derived and used to synthesize a lateral stability augmentation system (SAS), a longitudinal control augmentation system (CAS), and a FMC system. Fatigue life and cost analyses followed the control system synthesis, after which a comparative evaluation of the CCV and conventional tankers was made. This comparison indicated that the CCV weight and cost were lower but that, for this design iteration, the CCV fatigue life was shorter. Also, the CCV crew station acceleration was lower, but the acceleration at the boom operator station was higher relative to the corresponding conventional tanker. Comparison of the design processes used in the CCV and conventional design studies revealed that they were basically the same.
Body-freedom flutter of a 1/2-scale forward-swept-wing model, an experimental and analytical study
NASA Technical Reports Server (NTRS)
Chipman, R.; Rauch, F.; Rimer, M.; Muniz, B.
1984-01-01
The aeroelastic phenomenon known as body-freedom flutter (BFF), a dynamic instability involving aircraft-pitch and wing-bending motions which, though rarely experienced on conventional vehicles, is characteristic of forward swept wing (FSW) aircraft was investigated. Testing was conducted in the Langley transonic dynamics tunnel on a flying, cable-mounted, 1/2-scale model of a FSW configuration with and without relaxed static stability (RSS). The BFF instability boundaries were found to occur at significantly lower airspeeds than those associated with aeroelastic wing divergence on the same model. For those cases with RSS, a canard-based stability augmentation system (SAS) was incorporated in the model. This SAS was designed using aerodynamic data measured during a preliminary tunnel test in which the model was attached to a force balance. Data from the subsequent flutter test indicated that BFF speed was not dependent on open-loop static margin but, rather, on the equivalent closed-loop dynamics provided by the SAS. Servo-aeroelastic stability analyses of the flying model were performed using a computer code known as SEAL and predicted the onset of BFF reasonably well.
Three-dimensional imaging, an important factor of decision in breast augmentation.
de Runz, A; Boccara, D; Bertheuil, N; Claudot, F; Brix, M; Simon, E
2018-04-01
Since the beginning of the 21st century, three-dimensional imaging systems have been used more often in plastic surgery, especially during preoperative planning for breast surgery and to simulate the postoperative appearance of the implant in the patient's body. The main objective of this study is to assess the patients' attitudes regarding 3D simulation for breast augmentation. A study was conducted, which included women who were operated on for primary breast augmentation. During the consultation, a three-dimensional simulation with Crisalix was done and different sized implants were fitted in the bra. Thirty-eight women were included. The median age was 29.4, and the median prosthesis volume was 310mL. The median rank given regarding the final result was 9 (IQR: 8-9). Ninety percent of patients agreed (66% absolutely agreed, and 24% partially agreed) that the final product after breast augmentations was similar to the Crisalix simulation. Ninety-three percent of the patients believed that the three-dimensional simulation helped them choose their prosthesis (61% a lot and 32% a little). After envisaging a breast enlargement, patients estimated that the Crisalix system was absolutely necessary (21%), very useful (32%), useful (45%), or unnecessary (3%). Regarding prosthesis choice, an equal number of women preferred the 3D simulation (19 patients) as preferred using different sizes of implants in the bra (19 patients). The present study demonstrated that 3D simulation is actually useful for patients in order to envisage a breast augmentation. But it should be used as a complement to the classic method of trying different sized breast implants in the bra. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
[Association between oxytocin augmentation intervals and the risk of postpartum haemorrhage].
Loscul, C; Chantry, A-A; Caubit, L; Deneux-Tharaux, C; Goffinet, F; Le Ray, C
2016-09-01
To study the association between the duration of oxytocin augmentation intervals and the risk of postpartum haemorrhage (PPH) among primiparous women in spontaneous labour. Retrospective cohort including primiparous women in spontaneous labour who received oxytocin during labour (n=454). Oxytocin augmentation intervals were dichotomized in intervals<20minutes and≥20minutes. Obstetrical and neonatal issues were analyzed according to the duration oxytocin augmentation intervals. The association between oxytocin augmentation intervals and PPH was analyzed using univariate and multivariate analysis. Oxytocin augmentation intervals were shorter than 20minutes for 43.8% of the study population. The rate of PPH was higher (9.1% vs 3.5%; P=0.014), and the use of sulprostone was more frequent (6.5% vs 3.5%; P=0.013) if oxytocin augmentation intervals were shorter than 20minutes in comparison with intervals≥20minutes. The association between oxytocin augmentation intervals and PPH remains significant after adjustment on other PPH risk factors (adjusted OR=3.48, 95% CI [1.45-8.34]). The rate of adverse neonatal issue, defined by arterial pH at birth≤7.10 and/or 5minutes score d'Apgar≤7, was higher if oxytocin augmentation intervals were<20minutes (12.1% vs 4.3%; P=0.002). Our study demonstrated an increased risk of PPH for primiparous women in spontaneous labour who received oxytocin with augmentation intervals shorter than 20minutes. Copyright © 2016. Published by Elsevier Masson SAS.
An in-flight simulation of approach and landing of a STOL transport with adverse ground effect
NASA Technical Reports Server (NTRS)
Ellis, D. R.
1976-01-01
The results of an in-flight simulation program undertaken to study the problems of landing a representative STOL transport in the presence of adverse ground effects are presented. Landings were performed with variations in ground effect magnitude, ground effect lag, and thrust response. Other variations covered the effects of augmented lift response, SAS-failures, turbulence, segmented approach, and flare warning. The basic STOL airplane required coordinated use of both stick and throttle for consistently acceptable landings, and the presence of adverse ground effects made the task significantly more difficult. Ground effect lag and good engine response gave noticeable improvement, as did augmented lift response.
ERIC Educational Resources Information Center
Amrein-Beardsley, Audrey; Collins, Clarin
2012-01-01
The SAS Educational Value-Added Assessment System (SAS[R] EVAAS[R]) is the most widely used value-added system in the country. It is also self-proclaimed as "the most robust and reliable" system available, with its greatest benefit to help educators improve their teaching practices. This study critically examined the effects of SAS[R] EVAAS[R] as…
[Switching and combining strategies of antidepressant medications].
Charpeaud, Thomas; Moliere, Fanny; Bubrovszky, Maxime; Haesebaert, Frédéric; Allaïli, Najib; Bation, Rémy; Nieto, Isabel; Richieri, Raphaëlle; Saba, Ghassen; Bellivier, Frank; Bennabi, Djamila; Holtzmann, Jérôme; Camus, Vincent; Courtet, Philippe; Courvoisier, Pierre; d'Amato, Thierry; Doumy, Olivier; Garnier, Marion; Bougerol, Thierry; Lançon, Christophe; Haffen, Emmanuel; Leboyer, Marion; Llorca, Pierre-Michel; Vaiva, Guillaume; El-Hage, Wissam; Aouizerate, Bruno
2016-03-01
Switching antidepressant medication may be helpful in depressed patients having no benefit from the initial antidepressant treatment. Before considering switching strategy, the initial antidepressant treatment should produce no therapeutic effect after at least 4 weeks of administration at adequate dosage. Choosing an antidepressant of pharmacologically distinct profile fails to consistently demonstrate a significant superiority in terms of effectiveness over the switching to another antidepressant within the same pharmacological class. Augmenting SSRI/SNRIs with mirtazapine/mianserin has become the most recommended strategy of antidepressant combinations. Augmenting SSRI with tricyclic drugs is now a less recommended strategy of antidepressant combinations given the increased risk for the occurrence of pharmacokinetic drug-drug interactions and adverse effects. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Winklewski, Pawel J; Barak, Otto; Madden, Dennis; Gruszecka, Agnieszka; Gruszecki, Marcin; Guminski, Wojciech; Kot, Jacek; Frydrychowski, Andrzej F; Drvis, Ivan; Dujic, Zeljko
2015-01-01
The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on infrared radiation, called near-infrared transillumination/backscattering sounding (NIR-T/BSS). The experimental group consisted of seven breath-hold divers (six men). During testing, each participant performed a single maximal end-inspiratory breath hold. Apnoea consisted of the easy-going and struggle phases (characterised by involuntary breathing movements (IBMs)). Heart rate (HR) was determined using a standard ECG. BP was assessed using the photoplethysmography method. SaO2 was monitored continuously with pulse oximetry. A pneumatic chest belt was used to register thoracic and abdominal movements. Cerebral blood flow velocity (CBFV) was estimated by a 2-MHz transcranial Doppler ultrasonic probe. sas-TQ and cc-TQ were measured using NIR-T/BSS. Wavelet transform analysis was performed to assess cardiac contribution to BP, CBFV and cc-TQ oscillations. Mean BP and CBFV increased compared to baseline at the end of the easy phase and were further augmented by IBMs. cc-TQ increased compared to baseline at the end of the easy phase and remained stable during the IBMs. HR did not change significantly throughout the apnoea, although a trend toward a decrease during the easy phase and recovery during the IBMs was visible. Amplitudes of BP, CBFV and cc-TQ were augmented. sas-TQ and SaO2 decreased at the easy phase of apnoea and further decreased during the IBMs. Apnoea increases intracranial pressure and pial artery pulsation. Pial artery pulsation seems to be stabilised by the IBMs. Cardiac contribution to BP, CBFV and cc-TQ oscillations does not change throughout the apnoea.
Malchow, Berend; Keller, Katriona; Hasan, Alkomiet; Dörfler, Sebastian; Schneider-Axmann, Thomas; Hillmer-Vogel, Ursula; Honer, William G.; Schulze, Thomas G.; Niklas, Andree; Wobrock, Thomas; Schmitt, Andrea; Falkai, Peter
2015-01-01
Aerobic exercise has been shown to improve symptoms in multiepisode schizophrenia, including cognitive impairments, but results are inconsistent. Therefore, we evaluated the effects of an enriched environment paradigm consisting of bicycle ergometer training and add-on computer-assisted cognitive remediation (CACR) training. To our knowledge, this is the first study to evaluate such an enriched environment paradigm in multiepisode schizophrenia. Twenty-two multiepisode schizophrenia patients and 22 age- and gender-matched healthy controls underwent 3 months of endurance training (30min, 3 times/wk); CACR training (30min, 2 times/wk) was added from week 6. Twenty-one additionally recruited schizophrenia patients played table soccer (known as “foosball” in the United States) over the same period and also received the same CACR training. At baseline and after 6 weeks and 3 months, we measured the Global Assessment of Functioning (GAF), Social Adjustment Scale-II (SAS-II), schizophrenia symptoms (Positive and Negative Syndrome Scale), and cognitive domains (Verbal Learning Memory Test [VLMT], Wisconsin Card Sorting Test [WCST], and Trail Making Test). After 3 months, we observed a significant improvement in GAF and in SAS-II social/leisure activities and household functioning adaptation in the endurance training augmented with cognitive remediation, but not in the table soccer augmented with cognitive remediation group. The severity of negative symptoms and performance in the VLMT and WCST improved significantly in the schizophrenia endurance training augmented with cognitive remediation group from week 6 to the end of the 3-month training period. Future studies should investigate longer intervention periods to show whether endurance training induces stable improvements in everyday functioning. PMID:25782770
NASA Technical Reports Server (NTRS)
Skavdahl, H.; Patterson, D. H.
1972-01-01
The initial flight test phase of the modified C-8A airplane was conducted. The primary objective of the testing was to establish the basic airworthiness of the research vehicle. This included verification of the structural design and evaluation of the aircraft's systems. Only a minimum amount of performance testing was scheduled; this has been used to provide a preliminary indication of the airplane's performance and flight characteristics for future flight planning. The testing included flutter and loads investigations up to the maximum design speed. The operational characteristics of all systems were assessed including hydraulics, environmental control system, air ducts, the vectoring conical nozzles, and the stability augmentation system (SAS). Approaches to stall were made at three primary flap settings: up, 30 deg and 65 deg, but full stalls were not scheduled. Minimum control speeds and maneuver margins were checked. All takeoffs and landings were conventional, and STOL performance was not scheduled during this phase of the evaluation.
Security Controls in the Stockpoint Logistics Integrated Communications Environment (SPLICE).
1985-03-01
call programs as authorized after checks by the Terminal Management Subsystem on SAS databases . SAS overlays the TANDEM GUARDIAN operating system to...Security Access Profile database (SAP) and a query capability generating various security reports. SAS operates with the System Monitor (SMON) subsystem...system to DDN and other components. The first SAS component to be reviewed is the SAP database . SAP is organized into two types of files. Relational
Ostojic, Sergej M
2017-07-01
A confined absorption of exogenous creatine through creatine transporter (CRT1) seems to hamper its optimal uptake in bioenergetical deficits. Co-administration of guanidinoacetic acid (GAA) along with creatine could target other transport channels besides CRT1, and supremely improve cellular levels of creatine. This innovative approach might tackle tissues difficult to reach with conventional creatine interventions, providing a potentially more effective and safe mixture in clinical pharmacology and therapeutics. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Charles, Y P; Pelletier, H; Hydier, P; Schuller, S; Garnon, J; Sauleau, E A; Steib, J-P; Clavert, P
2015-05-01
Vertebroplasty prefilling or fenestrated pedicle screw augmentation can be used to enhance pullout resistance in elderly patients. It is not clear which method offers the most reliable fixation strength if axial pullout and a bending moment is applied. The purpose of this study is to validate a new in vitro model aimed to reproduce a cut out mechanism of lumbar pedicle screws, to compare fixation strength in elderly spines with different cement augmentation techniques and to analyze factors that might influence the failure pattern. Six human specimens (82-100 years) were instrumented percutaneously at L2, L3 and L4 by non-augmented screws, vertebroplasty augmentation and fenestrated screws. Cement distribution (2 ml PMMA) was analyzed on CT. Vertebral endplates and the rod were oriented at 45° to the horizontal plane. The vertebral body was held by resin in a cylinder, linked to an unconstrained pivot, on which traction (10 N/s) was applied until rupture. Load-displacement curves were compared to simultaneous video recordings. Median pullout forces were 488.5 N (195-500) for non-augmented screws, 643.5 N (270-1050) for vertebroplasty augmentation and 943.5 N (750-1084) for fenestrated screws. Cement augmentation through fenestrated screws led to significantly higher rupture forces compared to non-augmented screws (P=0.0039). The pullout force after vertebroplasty was variable and linked to cement distribution. A cement bolus around the distal screw tip led to pullout forces similar to non-augmented screws. A proximal cement bolus, as it was observed in fenestrated screws, led to higher pullout resistance. This cement distribution led to vertebral body fractures prior to screw pullout. The experimental setup tended to reproduce a pullout mechanism observed on radiographs, combining axial pullout and a bending moment. Cement augmentation with fenestrated screws increased pullout resistance significantly, whereas the fixation strength with the vertebroplasty prefilling method was linked to the cement distribution. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
The Environmental Technology Verification report discusses the technology and performance of Seal Assist System (SAS) for natural gas reciprocating compressor rod packing manufactured by A&A Environmental Seals, Inc. The SAS uses a secondary containment gland to collect natural g...
The report presents results of tests determining the efficacy of A&A Environmental Seals, Inc's Seal Assist System (SAS) in preventing natural gas compressor station's compressor rod packing leaks from escaping into the atmosphere. The SAS consists of an Emission Containment Glan...
The Mexican Sistema de Alerta Sismica (SAS) Experience
NASA Astrophysics Data System (ADS)
Espinosa-Aranda, J.; Rodriguez, F.
2003-12-01
The Mexico City's SAS is an Early Warning System developed in accordance with recommendations of foreign and national seismology experts, after the disaster generated in 1985 by the M8.1 Michoacan earthquake. The SAS aim is to help mitigate future seismic disasters in Mexico City (MC), mainly if the big forecast "Guerrero Earthquake" hits. In 1991 the SAS started its service in an experimental basis for evaluating its performance both with a group of basic education students in public schools, and with the emergency stop function for the Mexico City Metropolitan Subway System (METRO of MC); after this The Federal District Government (FDG) opened the SAS as a public service in August, 1993, shortly after the SAS warned, with more than 60 seconds of anticipation, the incoming effect of May 13, 1993, M5.8, and M6 double earthquake originated more than 300 Km from MC between Guerrero and Oaxaca, on the coast. That year, an initial technical flaw generated one false alert signal; the cause was readily corrected. The SAS has 12 seismic sensor stations covering a stripe close to 400 X 100 Km on the Guerrero's coast, between Papanoa and Punta Maldonado, that send information through a dedicated radio relay system to the SAS Central Control in MC., using the valuable support of some TELMEX field installations. Until August, 2003, the SAS sensor system has detected more than 1550 earthquakes in the 2.5
Airway and sleep disorders in patients with acromegaly.
Turan, Onur; Akinci, Barış; Ikiz, Ahmet Omer; Itil, Oya; Oztura, Ibrahim; Ada, Emel; Akdeniz, Bahri; Yener, Serkan; Kaya, Murat; Gedik, Arzu; Comlekci, Abdurrahman
2018-03-01
Acromegaly is a multisystemic disorder caused by excessive secretion of growth hormone (GH). Sleep-disordered breathing (SDB) such as sleep apnea syndrome (SAS) may occur in acromegaly. The aim of study was to assess the presence of sleep disorders and evaluate the systemic complications on respiratory, cardiovascular, and upper airway systems in acromegalic patients. The study group consisted of 30 acromegaly outpatients. GH and insulin-like growth factor 1 (IGF-1) measurements were obtained; body pletysmography, arterial blood gas analysis, tissue-doppler imaging, echocardiography, polysomnography, otorhinolaryngologic examination, and head-neck computed tomography were performed. Sixteen female (53.3%) and 14 male (46.7%) acromegalic patients had a mean age of 51.1 ± 13.2. GH was supressed in 19 patients (63.3%) when 11 had active acromegaly (36.7%). There were 17 patients with SAS (62.9%) (7: mild, 3:intermediate, 7:severe SAS) and average AHI was 16/h. Sixteen patients had predominantly obstructive SAS while one patient had predominantly central SAS. SAS was statistically more frequent in males than females (P = .015). The mean neck circumference was significantly longer in patients with SAS (P = .048). In SAS patients,the soft palate was elongated and thickened,which was statistically significant (P = .014 and P = .05).Vallecula-to-tongue distance was statistically longer in acromegalic patients with SAS (P = .007).There was a positive correlation between tonsil size,vallecula-to-tongue distance and AHI (r = 0.432, P = .045 and r = 0.512, P = .021, respectively). SDB seems to be common and clinically important in patients with acromegaly, particularly in men. The most frequent type of apnea in acromegalics is obstructive. Hormonal activity of acromegaly does not seem to have an effect on the development of SAS. Despite its high prevalence, SAS is frequently under-assessed in patients with acromegaly. Systemic complications and SDB should be researched in acromegalics. © 2017 John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Collins, Clarin
2014-01-01
This study examined the SAS Education Value-Added Assessment System (EVAAS®) in practice, as perceived and experienced by teachers in the Southwest School District (SSD). To evaluate teacher effectiveness, SSD is using SAS EVAAS® for high-stakes consequences more than any other district or state in the country. A mixed-method design including a…
NASA Astrophysics Data System (ADS)
Arai, K.; TAMA Collaboration
2008-07-01
Current effort of the TAMA project is focused on establishment of the interferometer operation with a new vibration isolation system, called 'Seismic Attenuation System' (SAS). The SAS employs a multiple stage structure to realize soft spring for all of directions, as well as utilizes active control systems to stabilize mechanical resonances in the low frequency region below 1 Hz. The SASs were installed for four test masses, resulting in improvement of cavity length fluctuation below 150 Hz. We describe the structure of the SAS and its local active control system, and the status of the interferometer.
INTERFACING SAS TO ORACLE IN THE UNIX ENVIRONMENT
SAS is an EPA standard data and statistical analysis software package while ORACLE is EPA's standard data base management system software package. RACLE has the advantage over SAS in data retrieval and storage capabilities but has limited data and statistical analysis capability....
NASA Astrophysics Data System (ADS)
Kim, M.; Pangle, L. A.; Cardoso, C.; Lora, M.; Meira, A.; Volkmann, T. H. M.; Wang, Y.; Harman, C. J.; Troch, P. A. A.
2015-12-01
Transit time distributions (TTDs) are an efficient way of characterizing complex transport dynamics of a hydrologic system. Time-invariant TTD has been studied extensively, but TTDs are time-varying under unsteady hydrologic systems due to both external variability (e.g., time-variability in fluxes), and internal variability (e.g., time-varying flow pathways). The use of "flow-weighted time" has been suggested to account for the effect of external variability on TTDs, but neglects the role of internal variability. Recently, to account both types of variability, StorAge Selection (SAS) function approaches were developed. One of these approaches enables the transport characteristics of a system - how the different aged water in the storage is sampled by the outflow - to be parameterized by time-variable probability distribution called the rank SAS (rSAS) function, and uses it directly to determine the time-variable TTDs resulting from a given timeseries of fluxes in and out of a system. Unlike TTDs, the form of the rSAS function varies only due to changes in flow pathways, but is not affected by the timing of fluxes alone. However, the relation between physical mechanisms and the time-varying rSAS functions are not well understood. In this study, relative effects of internal and external variability on the TTDs are examined using observations from a homogeneously packed 1 m3 sloping soil lysimeter. The observations suggest the importance of internal variability on TTDs, and reinforce the need to account for this variability using time-variable rSAS functions. Furthermore, the relative usefulness of two other formulations of SAS functions and the mortality rate (which plays a similar role to SAS functions in the McKendrick-von Foerster model of age-structured population dynamics) are also discussed. Finally, numerical modeling is used to explore the role of internal and external variability for hydrologic systems with diverse geomorphic and climate characteristics. This works will give an insight that which approach (or SAS function) is preferable under different conditions.
Bosc, R; Fitoussi, A; Pigneur, F; Tacher, V; Hersant, B; Meningaud, J-P
2017-08-01
The augmented reality on smart glasses allows the surgeon to visualize three-dimensional virtual objects during surgery, superimposed in real time to the anatomy of the patient. This makes it possible to preserve the vision of the surgical field and to dispose of added computerized information without the need to use a physical surgical guide or a deported screen. The three-dimensional objects that we used and visualized in augmented reality came from the reconstructions made from the CT-scans of the patients. These objects have been transferred through a dedicated application on stereoscopic smart glasses. The positioning and the stabilization of the virtual layers on the anatomy of the patients were obtained thanks to the recognition, by the glasses, of a tracker placed on the skin. We used this technology, in addition to the usual locating methods for preoperative planning and the selection of perforating vessels for 12 patients operated on a breast reconstruction, by perforating flap of deep lower epigastric artery. The "hands-free" smart glasses with two stereoscopic screens make it possible to provide the reconstructive surgeon with binocular visualization in the operative field of the vessels identified with the CT-scan. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
XMM-Newton Science Analysis Software: How to Bring New Technologies to Long-life Satellite Missions
NASA Astrophysics Data System (ADS)
Ibarra, A.; Calle, I.; Gabriel, C.; Salgado, J.; Osuna, P.
2009-09-01
We present here the beta version of the Remote Interface to SAS Analysis (RISA), a web service-based system that allows users the analysis of XMM-Newton data making use of all of the existing SAS functionalities. RISA takes advantage of GRID architecture to run SAS, achieving high performance in resource management. We are also making the SAS remote analysis compatible with present and future VO standards.
2004-03-01
Allison , Logistic Regression: Using the SAS System (Cary, NC: SAS Institute, Inc, 2001), 57. 23 using the likelihood ratio that SAS generates...21, respectively. 33 Jesse M. Rothstein, College Performance Predictions and the SAT ( Berkely , CA: UC
Structural alignment sensor. [laser applications and interferometry
NASA Technical Reports Server (NTRS)
Davis, L.; Buholz, N. E.; Gillard, C. W.; Huang, C. C.; Wells, W. M., III
1978-01-01
Comparative Michelson interferometers are discussed as well as the operating range potential of a structural alignment sensor (SAS) which requires only one laser mode. Schematics are presented for the distance measurement logic, the basic SAS system, the SAS optical layout, the coarse measurement signal processor, and the measured range resolution.
Data Management in the Euclid Science Archive System
NASA Astrophysics Data System (ADS)
de Teodoro, P.; Nieto, S.; Altieri, B.
2017-06-01
Euclid is the ESA M2 mission and a milestone in the understanding of the geometry of the Universe. In total Euclid will produce up to 26 PB per year of observations. The Science Archive Systems (SAS) belongs to the Euclid Archive System (EAS) that sits in the core of the Euclid Science Ground Segment (SGS). The SAS is being built at the ESAC Science Data Centre (ESDC), which is responsible for the development and operations of the scientific archives for the Astronomy, Planetary and Heliophysics missions of ESA. The SAS is focused on the needs of the scientific community and is intended to provide access to the most valuable scientific metadata from the Euclid mission. In this paper we describe the architectural design of the system, implementation progress and the main challenges from the data management point of view in the building of the SAS.
Coupling the System Analysis Module with SAS4A/SASSYS-1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanning, T. H.; Hu, R.
2016-09-30
SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced reactors, with an emphasis on sodium fast reactors. SAS4A/SASSYS-1 has been under development and in active use for nearly forty-five years, and is currently maintained by the U.S. Department of Energy under the Office of Advanced Reactor Technology. Although SAS4A/SASSYS-1 contains a very capable primary and intermediate system modeling component, PRIMAR-4, it also has some shortcomings: outdated data management and code structure makes extension of the PRIMAR-4 module somewhat difficult. The user input format formore » PRIMAR-4 also limits the number of volumes and segments that can be used to describe a given system. The System Analysis Module (SAM) is a fairly new code development effort being carried out under the U.S. DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. SAM is being developed with advanced physical models, numerical methods, and software engineering practices; however, it is currently somewhat limited in the system components and phenomena that can be represented. For example, component models for electromagnetic pumps and multi-layer stratified volumes have not yet been developed. Nor is there support for a balance of plant model. Similarly, system-level phenomena such as control-rod driveline expansion and vessel elongation are not represented. This report documents fiscal year 2016 work that was carried out to couple the transient safety analysis capabilities of SAS4A/SASSYS-1 with the system modeling capabilities of SAM under the joint support of the ART and NEAMS programs. The coupling effort was successful and is demonstrated by evaluating an unprotected loss of flow transient for the Advanced Burner Test Reactor (ABTR) design. There are differences between the stand-alone SAS4A/SASSYS-1 simulations and the coupled SAS/SAM simulations, but these are mainly attributed to the limited maturity of the SAM development effort. The severe accident modeling capabilities in SAS4A/SASSYS-1 (sodium boiling, fuel melting and relocation) will continue to play a vital role for a long time. Therefore, the SAS4A/SASSYS-1 modernization effort should remain a high priority task under the ART program to ensure continued participation in domestic and international SFR safety collaborations and design optimizations. On the other hand, SAM provides an advanced system analysis tool, with improved numerical solution schemes, data management, code flexibility, and accuracy. SAM is still in early stages of development and will require continued support from NEAMS to fulfill its potential and to mature into a production tool for advanced reactor safety analysis. The effort to couple SAS4A/SASSYS-1 and SAM is the first step on the integration of these modeling capabilities.« less
South Carolina Student Accountability System OSIRIS Instruction Manual.
ERIC Educational Resources Information Center
South Carolina State Dept. of Education, Columbia.
This manual expresses the South Carolina State Department of Education's understanding of the new, computerized school administration system called OSIRIS and the policy regarding its use with the Student Accountability System (SAS). The SAS is a method used to obtain a cumulative headcount of students served in certain programs specified in the…
NASA Technical Reports Server (NTRS)
Kocher, Joshua E; Gilliam, David P.
2005-01-01
Secure computing is a necessity in the hostile environment that the internet has become. Protection from nefarious individuals and organizations requires a solution that is more a methodology than a one time fix. One aspect of this methodology is having the knowledge of which network ports a computer has open to the world, These network ports are essentially the doorways from the internet into the computer. An assessment method which uses the nmap software to scan ports has been developed to aid System Administrators (SAs) with analysis of open ports on their system(s). Additionally, baselines for several operating systems have been developed so that SAs can compare their open ports to a baseline for a given operating system. Further, the tool is deployed on a website where SAs and Users can request a port scan of their computer. The results are then emailed to the requestor. This tool aids Users, SAs, and security professionals by providing an overall picture of what services are running, what ports are open, potential trojan programs or backdoors, and what ports can be closed.
Pearson, Amy C. S.; Subramanian, Arun; Schroeder, Darrell R.; Findlay, James Y.
2017-01-01
Background The surgical Apgar score (SAS) is a 10-point scale using the lowest heart rate, lowest mean arterial pressure, and estimated blood loss (EBL) during surgery to predict postoperative outcomes. The SAS has not yet been validated in liver transplantation patients, because typical blood loss usually exceeds the highest EBL category. Our primary aim was to develop a modified SAS for liver transplant (SAS-LT) by replacing the EBL parameter with volume of red cells transfused. We hypothesized that the SAS-LT would predict death or severe complication within 30 days of transplant with similar accuracy to current scoring systems. Methods A retrospective cohort of consecutive liver transplantations from July 2007 to November 2013 was used to develop the SAS-LT. The predictive ability of SAS-LT for early postoperative outcomes was compared with Model for End-stage Liver Disease, Sequential Organ Failure Assessment, and Acute Physiology and Chronic Health Evaluation III scores using multivariable logistic regression and receiver operating characteristic analysis. Results Of 628 transplants, death or serious perioperative morbidity occurred in 105 (16.7%). The SAS-LT (receiver operating characteristic area under the curve [AUC], 0.57) had similar predictive ability to Acute Physiology and Chronic Health Evaluation III, model for end-stage liver disease, and Sequential Organ Failure Assessment scores (0.57, 0.56, and 0.61, respectively). Seventy-nine (12.6%) patients were discharged from the ICU in 24 hours or less. These patients’ SAS-LT scores were significantly higher than those with a longer stay (7.0 vs 6.2, P < 0.01). The AUC on multivariable modeling remained predictive of early ICU discharge (AUC, 0.67). Conclusions The SAS-LT utilized simple intraoperative metrics to predict early morbidity and mortality after liver transplant with similar accuracy to other scoring systems at an earlier postoperative time point. PMID:29184910
RISA: Remote Interface for Science Analysis
NASA Astrophysics Data System (ADS)
Gabriel, C.; Ibarra, A.; de La Calle, I.; Salgado, J.; Osuna, P.; Tapiador, D.
2008-08-01
The Scientific Analysis System (SAS) is the package for interactive and pipeline data reduction of all XMM-Newton data. Freely distributed by ESA to run under many different operating systems, the SAS has been used by almost every one of the 1600 refereed scientific publications obtained so far from the mission. We are developing RISA, the Remote Interface for Science Analysis, which makes it possible to run SAS through fully configurable web service workflows, enabling observers to access and analyse data making use of all of the existing SAS functionalities, without any installation/download of software/data. The workflows run primarily but not exclusively on the ESAC Grid, which offers scalable processing resources, directly connected to the XMM-Newton Science Archive. A first project internal version of RISA was issued in May 2007, a public release is expected already within this year.
The development of augmented video system on postcards
NASA Astrophysics Data System (ADS)
Chen, Chien-Hsu; Chou, Yin-Ju
2013-03-01
This study focuses on development of augmented video system on traditional picture postcards. The system will provide users to print out the augmented reality marker on the sticker to stick on the picture postcard, and it also allows users to record their real time image and video to augment on that stick marker. According dynamic image, users can share travel moods, greeting, and travel experience to their friends. Without changing in the traditional picture postcards, we develop augmented video system on them by augmented reality (AR) technology. It not only keeps the functions of traditional picture postcards, but also enhances user's experience to keep the user's memories and emotional expression by augmented digital media information on them.
Clinical heterogeneity of patients with complex sleep apnea syndrome.
Kuźniar, Tomasz J; Kasibowska-Kuźniar, Kamilla; Ray, Daniel W; Freedom, Thomas
2013-12-01
The definition of complex sleep apnea (CompSAS) encompasses patients with obstructive sleep apnea (OSA) who develop central apnea activity upon restitution of airway patency. Presence of arterial hypertension (HTN), coronary artery disease (CAD) and heart failure (HF) have been proposed as risk factors for CompSAS among OSA patients. Using our database of patients with CompSAS, we examined the prevalence of these risk factors and defined other clinical characteristics of patients with CompSAS. Through retrospective search of the database, we examined the medical and clinical characteristics of consecutive patients diagnosed with CompSAS between 11/1/2006 and 6/30/2011 at NorthShore University HealthSystem. One hundred and fifty patients with CompSAS were identified. Among patients included in the study, 97 (64.7 %) had at least one risk factor for CompSAS, while 53 (35.3 %) did not have any of them. Prevalence of low left ventricular ejection fraction and hypocapnia were low. Therapeutic interventions consisted of several positive airway pressure therapies, mainly adaptive servo ventilation. A hundred and ten patients (73.3 %) complied with recommended therapy and improved clinically. Although most patients with CompSAS have cardiac comorbidities, about one third of patients do not have any risk factors of CompSAS prior to sleep testing. Further research on factors involved in development of CompSAS will allow for better tailoring of therapy to pathophysiology involved in an individual case.
Psychosocial stress alters the strength of reticulospinal input to the human upper trapezius.
Marker, Ryan J; Campeau, Serge; Maluf, Katrina S
2017-01-01
Psychosocial stress has been shown to influence several aspects of human motor control associated with the fight-or-flight response, including augmentation of upper trapezius muscle activity. Given the established role of the reticular formation in arousal, this study investigated the contribution of reticulospinal activation to trapezius muscle activity during exposure to an acute psychosocial stressor. Twenty-five healthy adults were exposed to startling acoustic stimuli (SAS) while performing a motor task during periods of low and high psychosocial stress. Acoustic startle reflexes (ASRs) were recorded in the upper trapezius during low intensity contractions using both surface and intramuscular electromyography. Exposure to the stressor increased subjective and physiological measures of arousal (P < 0.01). The majority of participants demonstrated inhibitory ASRs, whereas a small subgroup with significantly higher trait anxiety (n = 5) demonstrated excitatory ASRs in the low stress condition. Changes in synaptic input for inhibitory ASRs were confirmed by decreases in the discharge rate of single motor units in response to the SAS. ASRs decreased in magnitude for all participants during exposure to the acute psychosocial stressor. These findings suggest that the reticular formation has predominately inhibitory effects on the human upper trapezius during an ongoing motor task and that disinhibition caused by psychosocial stress may contribute to augmentation of trapezius muscle activity. Further research is required to investigate mechanisms underlying the complex ASRs characterized by this study, particularly the phase reversal to excitatory responses observed among more anxious individuals. This study is the first to quantify stress-evoked changes in the acoustic startle reflex in the upper trapezius muscle of humans, and our findings reveal a complex pattern of inhibitory and facilitatory responses consistent with observations in nonhuman primates. We further demonstrate that psychosocial stress consistently reduces the amplitude of these responses. These findings have implications for the control of motor behaviors in response to stress. Copyright © 2017 the American Physiological Society.
Psychosocial stress alters the strength of reticulospinal input to the human upper trapezius
Marker, Ryan J.; Campeau, Serge
2016-01-01
Psychosocial stress has been shown to influence several aspects of human motor control associated with the fight-or-flight response, including augmentation of upper trapezius muscle activity. Given the established role of the reticular formation in arousal, this study investigated the contribution of reticulospinal activation to trapezius muscle activity during exposure to an acute psychosocial stressor. Twenty-five healthy adults were exposed to startling acoustic stimuli (SAS) while performing a motor task during periods of low and high psychosocial stress. Acoustic startle reflexes (ASRs) were recorded in the upper trapezius during low intensity contractions using both surface and intramuscular electromyography. Exposure to the stressor increased subjective and physiological measures of arousal (P < 0.01). The majority of participants demonstrated inhibitory ASRs, whereas a small subgroup with significantly higher trait anxiety (n = 5) demonstrated excitatory ASRs in the low stress condition. Changes in synaptic input for inhibitory ASRs were confirmed by decreases in the discharge rate of single motor units in response to the SAS. ASRs decreased in magnitude for all participants during exposure to the acute psychosocial stressor. These findings suggest that the reticular formation has predominately inhibitory effects on the human upper trapezius during an ongoing motor task and that disinhibition caused by psychosocial stress may contribute to augmentation of trapezius muscle activity. Further research is required to investigate mechanisms underlying the complex ASRs characterized by this study, particularly the phase reversal to excitatory responses observed among more anxious individuals. NEW & NOTEWORTHY This study is the first to quantify stress-evoked changes in the acoustic startle reflex in the upper trapezius muscle of humans, and our findings reveal a complex pattern of inhibitory and facilitatory responses consistent with observations in nonhuman primates. We further demonstrate that psychosocial stress consistently reduces the amplitude of these responses. These findings have implications for the control of motor behaviors in response to stress. PMID:27832595
Tracking social motivation systems deficits: the affective neuroscience view of autism.
Carré, Arnaud; Chevallier, Coralie; Robel, Laurence; Barry, Caroline; Maria, Anne-Solène; Pouga, Lydia; Philippe, Anne; Pinabel, François; Berthoz, Sylvie
2015-10-01
Abnormal functioning of primary brain systems that express and modulate basic emotional drives are increasingly considered to underlie mental disorders including autism spectrum disorders. We hypothesized that ASD are characterized by disruptions in the primary systems involved in the motivation for social bonding. Twenty adults with ASD were compared to 20 neurotypical participants on the basis of self-reports and clinical assessments, including the Social Anhedonia Scale (SAS) and the Affective Neuroscience Personality Scales (ANPS). ASD diagnosis was related to SAS, as well as to positive (PLAYFULNESS) and negative (FEAR) ANPS-traits. In the overall sample, levels of autistic traits (AQ) were related to SAS and PLAYFULNESS. We argue that PLAYFULNESS could be at the root of social bonding impairments in ASD.
System definition phase and acquisition phase project plan for Small Astronomy Satellite SAS-D
NASA Technical Reports Server (NTRS)
1971-01-01
The objective of the SAS-D project is to conduct spectral distribution studies of celestial ultraviolet sources using an Explorer-class spacecraft launched by a Delta vehicle into a geosynchronous orbit in the last half of 1975. The telescope system is intended for use by guest astronomers for a major portion of the total observing time. The concept of the overall system, designed to resemble functionally the operation of a ground-based observatory, should maximize the usefulness of the instrument to the astronomical community by limiting the amount of special instruction needed to use the spaceborne telescope. The SAS-D mission will obtain information on what stars, nebulae, and galaxies are and how they develop.
Ito, A; Kawakami, H; Ishikawa, N; Ito, M; Oikawa, T; Sato, A; Umita, T
2017-05-01
Accelerated release of potassium (K), magnesium (Mg) and phosphorus (P) from surplus activated sludge (SAS) was investigated to develop a new system for the recovery of the elements. Anaerobic cultivation of SAS during 24 h released 78% of K and about 50% of Mg and P from SAS more effectively compared to aerobic cultivation (K: 40%, Mg: 15%, P: 15%). Furthermore, the addition of sodium acetate as an organic carbon source remarkably accelerated the release of K, Mg and P from SAS under anaerobic condition. However, no increase in the maximum release efficiencies was observed. The elements released from SAS could be transferred to separate liquid with the existing mechanical thickener and be recovered as MgKPO 4 by some additional process. Furthermore, the removal of the elements from SAS would inhibit the formation of struvite causing the blockage of sludge transport pipe after anaerobic digestion process of thickened sludge.
Remote sensing and geographic information system for appraisal of salt-affected soils in India.
Singh, Gurbachan; Bundela, D S; Sethi, Madhurama; Lal, Khajanchi; Kamra, S K
2010-01-01
Quantification of the nature, extent, and spatial distribution of salt-affected soils (SAS) for India and the world is essential for planning and implementing reclamation programs in a timely and cost-effective manner for sustained crop production. The national extent of SAS for India over the last four decades was assessed by conventional and remote sensing approaches using diverse methodologies and class definitions and ranged from 6.0 to 26.1 million hectares (Mha) and 1.2 to 10.1 Mha, respectively. In 1966, an area of 6 Mha under SAS was first reported using the former approach. Three national estimates, obtained using remote sensing, were reconciled using a geographic information system, resulting in an acceptable extent of 6.73 Mha. Moderately and severely salt-encrusted lands having large contiguous area have been correctly mapped, but slightly salt-encrusted land having smaller affected areas within croplands has not been accurately mapped. Recent satellite sensors (e.g., Resourcesat-1, Cartosat-2, IKONOS-II, and RISAT-2), along with improved image processing techniques integrated with terrain and other spatial data using a geographic information system, are enabling mapping at large scale. Significant variations in salt encrustation at the surface caused by soil moisture, waterlogging conditions, salt-tolerant crops, and dynamics of subsurface salts present constraints in appraisal, delineation, and mapping efforts. The article provides an overview of development, identification, characterization, and delineation of SAS, past and current national scenarios of SAS using conventional and remote sensing approaches, reconciliation of national estimates, issues of SAS mapping, and future scope.
Augmentative Communication for Children with Deaf-Blindness: Guidelines for Decision-Making.
ERIC Educational Resources Information Center
Cress, Cynthia J.; And Others
This manual is intended to assist in developing augmentative communication systems for deaf-blind children. After a brief introduction, section II provides an overview of general augmentative communication systems and theory. Section III presents a general decision-making process for developing and selecting augmentative communication systems for…
The standardized functional support sectional for the Small Astronomy Satellite (SAS)
NASA Technical Reports Server (NTRS)
Townsend, M. R.
1974-01-01
The standardized functional support section for the improved Small Astronomy Satellite (SAS) spacecraft, which can be used virtually without change for a wide variety of experimental packages and missions, is described. This functional support section makes the spacecraft remarkably flexible for a small satellite. Able to point its thrust axis to any direction in space, it can also spin or slow its outer body rotation to zero for star- or earth-locked pointing of side-viewing experiments. It features a reprogrammable telemetry system, a delayed command system, and an improved control system. Experiments can be built independently and attached to the SAS spacecraft just prior to final acceptance testing and launch. The spacecraft subsystems are described in detail. Included are a summary of the spacecraft characteristics, special design considerations, project reliability requirements, and environmental test conditions. It is intended that this new functional support section afford virtual off-the-shelf availability of the SAS spacecraft to independently built experiments, thus providing quick response time and minimum cost in meeting a wide variety of experimenter needs.
Multifractal spectra of laser Doppler flowmetry signals in healthy and sleep apnea syndrome subjects
NASA Astrophysics Data System (ADS)
Buard, Benjamin; Trzepizur, Wojciech; Mahe, Guillaume; Chapeau-Blondeau, François; Rousseau, David; Gagnadoux, Frédéric; Abraham, Pierre; Humeau, Anne
2009-07-01
Laser Doppler flowmetry (LDF) signals give a peripheral view of the cardiovascular system. To better understand the possible modifications brought by sleep apnea syndrome (SAS) in LDF signals, we herein propose to analyze the complexity of such signals in obstructive SAS subjects, and to compare the results with those obtained in healthy subjects. SAS is a pathology that leads to a drop in the parasympathetic tone associated with an increase in the sympathetic tone in awakens SAS patients. Nine men with obstructive SAS and nine healthy men participated awaken in our study and LDF signals were recorded in the forearm. In our work, complexity of LDF signals is analyzed through the computation and analysis of their multifractal spectra. The multifractal spectra are estimated by first estimating the discrete partition function of the signals, then by determining their Renyi exponents with a linear regression, and finally by computing their Legendre transform. The results show that, at rest, obstructive SAS has no or little impact on the multifractal spectra of LDF signals recorded in the forearm. This study shows that the physiological modifications brought by obstructive SAS do not modify the complexity of LDF signals when recorded in the forearm.
Transaction Costs and Cost Breaches in Major Defense Acquisition Programs
2014-02-04
bases, schools, missile storage facilities, maintenance facilities, medical/ dental clinics, libraries, and military family housing (DAU, 2011b...AIM-9_Sidewinder Allison, P. D. (2001). Logistic regression using the SAS system. Cary , NC: SAS Institute. Angelis, D., Dillard, J., Franck, C
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-26
... System. OMB Control Number: Pending. Type of Review: New collection, request for a new OMB Control Number... been issued the required two factor authentication tokens can access the FS SAS. The FS SAS allows...
C-C1-04: How to Win Friends and Influence People with the SAS Output Delivery System
Tolbert, William
2010-01-01
Background and Aims: Long-time SAS users remember the days when SAS output was embarrassingly ugly. Version 7 saw the introduction of the Output Delivery System (ODS). ODS has matured into a very capable subsystem that gives users powerful reporting options. This presentation will highlight useful features and outline a macro-based system for handling multiple ODS destinations simultaneously. Nowadays there is no excuse for ugly SAS output! When building reports, SAS users should think about the needs of those using the reports. Some people just want to review frequency tables, and are happy to do so on a monitor. Others want to be able to print data for review in a meeting. And, there are always those that want to work with the data in a spreadsheet. Consider the ideal formats for each of the users outlined above. For the casual data browser, HTML output is ideal. For printing, PDF is preferred. And for the additional analysis, Excel is a popular option. With ODS, we can meet all of these needs. Methods: Because ODS permits opening multiple output destinations simultaneously, a single procedure can be used to generate data in HTML, PDF, and Excel at once. The presentation will demonstrate the following: o- basic ODS syntax for HTML, PDF, and Excel output o- custom HTML table of contents o- using the ExcelXP tagset for multi-tab spreadsheets o- a custom macro for managing multiple ODS destinations simultaneously o- simple PROC Template code for easy customization o- techniques for consistent output from multiple platforms. Results: The techniques outlined here have been well-received in a variety of business reporting environments. Conclusions: The SAS ODS provides a wide array of reporting options. Don’t limit yourself to just one type of output.
The SAS4A/SASSYS-1 Safety Analysis Code System, Version 5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanning, T. H.; Brunett, A. J.; Sumner, T.
The SAS4A/SASSYS-1 computer code is developed by Argonne National Laboratory for thermal, hydraulic, and neutronic analysis of power and flow transients in liquidmetal- cooled nuclear reactors (LMRs). SAS4A was developed to analyze severe core disruption accidents with coolant boiling and fuel melting and relocation, initiated by a very low probability coincidence of an accident precursor and failure of one or more safety systems. SASSYS-1, originally developed to address loss-of-decay-heat-removal accidents, has evolved into a tool for margin assessment in design basis accident (DBA) analysis and for consequence assessment in beyond-design-basis accident (BDBA) analysis. SAS4A contains detailed, mechanistic models of transientmore » thermal, hydraulic, neutronic, and mechanical phenomena to describe the response of the reactor core, its coolant, fuel elements, and structural members to accident conditions. The core channel models in SAS4A provide the capability to analyze the initial phase of core disruptive accidents, through coolant heat-up and boiling, fuel element failure, and fuel melting and relocation. Originally developed to analyze oxide fuel clad with stainless steel, the models in SAS4A have been extended and specialized to metallic fuel with advanced alloy cladding. SASSYS-1 provides the capability to perform a detailed thermal/hydraulic simulation of the primary and secondary sodium coolant circuits and the balance-ofplant steam/water circuit. These sodium and steam circuit models include component models for heat exchangers, pumps, valves, turbines, and condensers, and thermal/hydraulic models of pipes and plena. SASSYS-1 also contains a plant protection and control system modeling capability, which provides digital representations of reactor, pump, and valve controllers and their response to input signal changes.« less
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... power-operated systems. 29.672 Section 29.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated system is necessary to show...
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... power-operated systems. 29.672 Section 29.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated system is necessary to show...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... power-operated systems. 27.672 Section 27.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... power-operated systems. 29.672 Section 29.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated system is necessary to show...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... power-operated systems. 27.672 Section 27.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... power-operated systems. 29.672 Section 29.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated system is necessary to show...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... power-operated systems. 27.672 Section 27.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... power-operated systems. 27.672 Section 27.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... power-operated systems. 25.672 Section 25.672 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the functioning of stability augmentation or other automatic or power-operated systems is necessary to show...
Development of a space activity suit
NASA Technical Reports Server (NTRS)
Annis, J. F.; Webb, P.
1971-01-01
The development of a series of prototype space activity suit (SAS) assemblies is discussed. The SAS is a new type of pressure suit designed especially for extravehicular activity. It consists of a set of carefully tailored elastic fabric garments which have been engineered to supply sufficient counterpressure to the body to permit subjects to breath O2 at pressures up to 200 mm Hg without circulatory difficulty. A closed, positive pressure breathing system (PPBS) and a full bubble helmet were also developed to complete the system. The ultimate goal of the SAS is to improve the range of activity and decrease the energy cost of work associated with wearing conventional gas filled pressure suits. Results are presented from both laboratory (1 atmosphere) and altitude chamber tests with subjects wearing various SAS assemblies. In laboratory tests lasting up to three hours, the SAS was worn while subjects breathed O2 at pressures up to 170 mm Hg without developing physiological problems. The only physiological symptoms apparent were a moderate tachycardia related to breathing pressures above 130 mm Hg, and a small collection of edema fluid in the hands. Both problems were considered to be related to areas of under-pressurization by the garments. These problems, it is suggested, can ultimately be corrected by the development of new elastic fabrics and tailoring techniques. Energy cost of activity, and mobility and dexterity of subjects in the SAS, were found to be superior to those in comparable tests on subjects in full pressure suits.
NASA Astrophysics Data System (ADS)
Seifollahi, Alireza
It is said that future of the world is based on space exploration which leads us to think more about low cost and light weight instruments. Cheap and sensitive instruments should be de-signed and replace the expensive ones. One of the required instruments in space ships is gyroscope controls the direction of space ship. In this article I am going to give an idea to use optical properties in a new gyroscope which will be cheaper as well as more sensitive in com-pare with most of the being used normal gyroscope nowadays. This instrument uses an optical system to measure the angular changes in the direction of a space craft movements in any of the three axels. Any movement, even very small one, will move a crystal bulb which is lashed by some narrow elastic bands in a fixed box surrounded by three optical sources and light meters. Light meters measure the attitude and the angel of changes in the light beams going through the bulb which is related to the amount of changes in the space craft directions. The system will be very sensitive even against movement around its access. As an electro digital device in connection to a Main Process Unit (MPU) it can be used in Stability Augmentation System (SAS) in a space ship. The sensitivity rate of the instrument will be based on the quality and sensitivity of the light meters.
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
14 CFR 23.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... CATEGORY AIRPLANES Design and Construction Control Systems § 23.672 Stability augmentation and automatic... systems must not activate the control system. (b) The design of the stability augmentation system or of... thereof, or by overriding the failure by movement of the flight controls in the normal sense. (c) It must...
Global navigation satellite systems performance analysis and augmentation strategies in aviation
NASA Astrophysics Data System (ADS)
Sabatini, Roberto; Moore, Terry; Ramasamy, Subramanian
2017-11-01
In an era of significant air traffic expansion characterized by a rising congestion of the radiofrequency spectrum and a widespread introduction of Unmanned Aircraft Systems (UAS), Global Navigation Satellite Systems (GNSS) are being exposed to a variety of threats including signal interferences, adverse propagation effects and challenging platform-satellite relative dynamics. Thus, there is a need to characterize GNSS signal degradations and assess the effects of interfering sources on the performance of avionics GNSS receivers and augmentation systems used for an increasing number of mission-essential and safety-critical aviation tasks (e.g., experimental flight testing, flight inspection/certification of ground-based radio navigation aids, wide area navigation and precision approach). GNSS signal deteriorations typically occur due to antenna obscuration caused by natural and man-made obstructions present in the environment (e.g., elevated terrain and tall buildings when flying at low altitude) or by the aircraft itself during manoeuvring (e.g., aircraft wings and empennage masking the on-board GNSS antenna), ionospheric scintillation, Doppler shift, multipath, jamming and spurious satellite transmissions. Anyone of these phenomena can result in partial to total loss of tracking and possible tracking errors, depending on the severity of the effect and the receiver characteristics. After designing GNSS performance threats, the various augmentation strategies adopted in the Communication, Navigation, Surveillance/Air Traffic Management and Avionics (CNS + A) context are addressed in detail. GNSS augmentation can take many forms but all strategies share the same fundamental principle of providing supplementary information whose objective is improving the performance and/or trustworthiness of the system. Hence it is of paramount importance to consider the synergies offered by different augmentation strategies including Space Based Augmentation System (SBAS), Ground Based Augmentation System (GBAS), Aircraft Based Augmentation System (ABAS) and Receiver Autonomous Integrity Monitoring (RAIM). Furthermore, by employing multi-GNSS constellations and multi-sensor data fusion techniques, improvements in availability and continuity can be obtained. SBAS is designed to improve GNSS system integrity and accuracy for aircraft navigation and landing, while an alternative approach to GNSS augmentation is to transmit integrity and differential correction messages from ground-based augmentation systems (GBAS). In addition to existing space and ground based augmentation systems, GNSS augmentation may take the form of additional information being provided by other on-board avionics systems, such as in ABAS. As these on-board systems normally operate via separate principles than GNSS, they are not subject to the same sources of error or interference. Using suitable data link and data processing technologies on the ground, a certified ABAS capability could be a core element of a future GNSS Space-Ground-Aircraft Augmentation Network (SGAAN). Although current augmentation systems can provide significant improvement of GNSS navigation performance, a properly designed and flight-certified SGAAN could play a key role in trusted autonomous system and cyber-physical system applications such as UAS Sense-and-Avoid (SAA).
Noncontact respiration-monitoring system using fiber grating sensor
NASA Astrophysics Data System (ADS)
Sato, Isao; Nakajima, Masato
2004-10-01
In this research, the new non-contact breathing motion monitoring system using Fiber Grating 3-dimension Sensor is used to measure the respiratory movement of the chest and the abdomen and the shape of the human body simultaneously. Respiratory trouble during sleep brings about various kinds of diseases. Particularly, Sleep Apnea Syndrome (SAS), which restricts respiration during sleep, has been in the spotlight in recent years. However, present equipment for analyzing the blessing motion requires attaching various sensors on the patient's body. This system adopted two CCD cameras to measure the movements of projected infrared bright spots on the patient's body which measure the body form, breathing motion of the chest and breathing motion of the abdomen in detail. Since the equipment does not contact the patient's body, the patient feels incompatibility, and there is no necessity to worry about the equipment coming off. Sleep Apnea Syndrome is classified into three types by their respiratory pattern-Obstructive, Central and Mixed SAS based on the characteristic. This paper reports the method of diagnosing SAS automatically. It is thought that this method will be helpful not only for the diagnosis of SAS but also for the diagnosis of other kinds of complicated respiratory disease.
A preliminary look at control augmented dynamic response of structures
NASA Technical Reports Server (NTRS)
Ryan, R. S.; Jewell, R. E.
1983-01-01
The augmentation of structural characteristics, mass, damping, and stiffness through the use of control theory in lieu of structural redesign or augmentation was reported. The standard single-degree-of-freedom system was followed by a treatment of the same system using control augmentation. The system was extended to elastic structures using single and multisensor approaches and concludes with a brief discussion of potential application to large orbiting space structures.
Research on Design of MUH Attitude Stability Augmentation Control System
NASA Astrophysics Data System (ADS)
Fan, Shigang
2017-09-01
Attitude stability augmentation control system with a lower cost need to be designed so that MUH (Mini Unmanned Helicopter) can adapt to different types of geographic environment and fly steadily although the weather may be bad. Attitude feedback was calculated mainly by filtering estimation within attitude acquisition module in this system. Stability augmentation can be improved mainly by PI. This paper will depict running principle and designing process of MUH attitude stability augmentation control system and algorithm that is considered as an important part in this system.
Augmented Reality Imaging System: 3D Viewing of a Breast Cancer.
Douglas, David B; Boone, John M; Petricoin, Emanuel; Liotta, Lance; Wilson, Eugene
2016-01-01
To display images of breast cancer from a dedicated breast CT using Depth 3-Dimensional (D3D) augmented reality. A case of breast cancer imaged using contrast-enhanced breast CT (Computed Tomography) was viewed with the augmented reality imaging, which uses a head display unit (HDU) and joystick control interface. The augmented reality system demonstrated 3D viewing of the breast mass with head position tracking, stereoscopic depth perception, focal point convergence and the use of a 3D cursor and joy-stick enabled fly through with visualization of the spiculations extending from the breast cancer. The augmented reality system provided 3D visualization of the breast cancer with depth perception and visualization of the mass's spiculations. The augmented reality system should be further researched to determine the utility in clinical practice.
Statin-Associated Side Effects.
Thompson, Paul D; Panza, Gregory; Zaleski, Amanda; Taylor, Beth
2016-05-24
Hydroxy-methyl-glutaryl-coenzyme A (HMG-CoA) reductase inhibitors or statins are well tolerated, but associated with various statin-associated symptoms (SAS), including statin-associated muscle symptoms (SAMS), diabetes mellitus (DM), and central nervous system complaints. These are "statin-associated symptoms" because they are rare in clinical trials, making their causative relationship to statins unclear. SAS are, nevertheless, important because they prompt dose reduction or discontinuation of these life-saving mediations. SAMS is the most frequent SAS, and mild myalgia may affect 5% to 10% of statin users. Clinically important muscle symptoms, including rhabdomyolysis and statin-induced necrotizing autoimmune myopathy (SINAM), are rare. Antibodies against HMG-CoA reductase apparently provoke SINAM. Good evidence links statins to DM, but evidence linking statins to other SAS is largely anecdotal. Management of SAS requires making the possible diagnosis, altering or discontinuing the statin treatment, and using alternative lipid-lowering therapy. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ishizaki, Yoshihiro; Kobayashi, Misao; Suzuki, Hironori; Futagami, Koichi
It is very suitable to select the polymer materials for the housings of surge arresters (SAs), because the polymer materials are generally soft and light weight. Therefore, many kinds of polymer-housed SAs using various polymer materials have been developed, and expanding into many countries. Considering these backgrounds, the JEC technical report (JEC-TR) 23002-2008; polymer-housed surge arrester(1) has been established based on the existent relevant standards of arresters, such as JEC-2371-2003; Insulator-housed surge arresters(2) and IEC 60099-4 Edition 2.2, Metal-oxide surge arresters (MOSAs) without gaps for a.c. systems(3) in order to introduce the technology and provide a common guide for testing of polymer-housed SAs. According as the JEC-TR, the various new applications of the polymer-housed SAs, which are caused by superior advantages such as compact, light weight, safe failure mode, anti-seismic performance, anti-pollution performance and cost efficiency design, have been realized recently in Japan. Therefore, this paper gives specific consideration on the superior performance of the polymer-housed SAs and the evaluation methods of the polymer-housed SAs, because there are some issues in the existent standards to be solved.
Gislason, T; Hedner, J; Terenius, L; Bisette, G; Nemeroff, C B
1992-09-01
The cerebrospinal fluid (CSF) concentrations of thyrotropin-releasing hormone (TRH), substance P (SP), 5-hydroxyindoleacetic acid (5-HIAA), homovanillic acid (HVA), and 3-methoxy-4-hydroxyphenyl glycol (MHPG) were measured in 15 consecutive patients with the sleep apnea syndrome (SAS) and in healthy control subjects. Second measurements were performed 6 months after surgical treatment in 10 of the patients. The mean (+/- SD) concentration of TRH-like immunoreactive material (TRH-LIM) (pg/ml) did not differ significantly between patients with SAS (8.1 +/- 2.8) and control subjects (7.5 +/- 2.2). However, postoperatively, this concentration was increased in the six clinically cured patients with SAS, from 6.9 +/- 2.7 to 9.4 +/- 1.6 (p less than 0.03). Substance P-like immunoreactive material (SP-LIM) was higher in untreated patients with SAS than in control subjects: 19.2 +/- 6.7 versus 14.4 +/- 4.2 fmol/ml (p less than 0.02), and the level remained high after operation in the group treated surgically. The HVA, 5-HIAA, and MHPG concentrations were similar in patients with SAS and control subjects, and no consistent changes were found postoperatively. The CSF deviations in TRH-LIM and SP-LIM concentrations in the patients may reflect a primary central nervous system defect or they may be secondary to intermittent nocturnal hypoxia, progressive hypercapnia, and/or sleep fragmentation. In this sense, both these systems may be markers of SAS-SP as a "trait" marker and TRH as an indicator of the current state.
Augmented Reality for Close Quarters Combat
None
2018-01-16
Sandia National Laboratories has developed a state-of-the-art augmented reality training system for close-quarters combat (CQB). This system uses a wearable augmented reality system to place the user in a real environment while engaging enemy combatants in virtual space (Boston Dynamics DI-Guy). Umbra modeling and simulation environment is used to integrate and control the AR system.
D3D augmented reality imaging system: proof of concept in mammography.
Douglas, David B; Petricoin, Emanuel F; Liotta, Lance; Wilson, Eugene
2016-01-01
The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called "depth 3-dimensional (D3D) augmented reality". A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice.
User’s Guide for the SAS (Stand-Off Attack Simulation) Computer Model.
1982-01-15
A99QAXFD000-01 Albuquerque, New Mexico 87110 I1. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT DATE Director 15 January 1982 Defense Nuclear Aqency 13...computer model. SAS is an effective survivability and security system design tool which allows an analyst to compare the relative effectiveness of selected...mounted against other systems during uploading for dispersal or for non -emergency relocation. GLCM and LANCE must be mobilized and formed into convoys
Introduction to the scientific application system of DAMPE (On behalf of DAMPE collaboration)
NASA Astrophysics Data System (ADS)
Zang, Jingjing
2016-07-01
The Dark Matter Particle Explorer (DAMPE) is a high energy particle physics experiment satellite, launched on 17 Dec 2015. The science data processing and payload operation maintenance for DAMPE will be provided by the DAMPE Scientific Application System (SAS) at the Purple Mountain Observatory (PMO) of Chinese Academy of Sciences. SAS is consisted of three subsystems - scientific operation subsystem, science data and user management subsystem and science data processing subsystem. In cooperation with the Ground Support System (Beijing), the scientific operation subsystem is responsible for proposing observation plans, monitoring the health of satellite, generating payload control commands and participating in all activities related to payload operation. Several databases developed by the science data and user management subsystem of DAMPE methodically manage all collected and reconstructed science data, down linked housekeeping data, payload configuration and calibration data. Under the leadership of DAMPE Scientific Committee, this subsystem is also responsible for publication of high level science data and supporting all science activities of the DAMPE collaboration. The science data processing subsystem of DAMPE has already developed a series of physics analysis software to reconstruct basic information about detected cosmic ray particle. This subsystem also maintains the high performance computing system of SAS to processing all down linked science data and automatically monitors the qualities of all produced data. In this talk, we will describe all functionalities of whole DAMPE SAS system and show you main performances of data processing ability.
The Augmentation System Framework.
ERIC Educational Resources Information Center
Engelbart, Doug; Hooper, Kristina
1986-01-01
Augmentation systems are composed of things that will add to what the human is genetically endowed with in order to extend the net capabilities that a human or human organization can apply to the problems or goals of human society. A broad brush categorization of the components of an augmentation system includes three distinct though interacting…
Functional Reflective Polarizer for Augmented Reality and Color Vision Deficiency
2016-03-03
Functional reflective polarizer for augmented reality and color vision deficiency Ruidong Zhu, Guanjun Tan, Jiamin Yuan, and Shin-Tson Wu* College...polarizer that can be incorporated into a compact augmented reality system. The design principle of the functional reflective polarizer is explained and...augment reality system is relatively high as compared to a polarizing beam splitter or a conventional reflective polarizer. Such a functional reflective
Collection and Analysis of Augmented Weigh-In-Motion Data
DOT National Transportation Integrated Search
1996-12-01
Traffic loading data are essential for the planning and design of adequate and cost-effective highway pavements. Data from an augmented weigh-in-motion (WIM) system have been collected and analyzed. The augmented WIM systems, which comprise bending-p...
NASA Technical Reports Server (NTRS)
Sizlo, T. R.; Berg, R. A.; Gilles, D. L.
1979-01-01
An augmentation system for a 230 passenger, twin engine aircraft designed with a relaxation of conventional longitudinal static stability was developed. The design criteria are established and candidate augmentation system control laws and hardware architectures are formulated and evaluated with respect to reliability, flying qualities, and flight path tracking performance. The selected systems are shown to satisfy the interpreted regulatory safety and reliability requirements while maintaining the present DC 10 (study baseline) level of maintainability and reliability for the total flight control system. The impact of certification of the relaxed static stability augmentation concept is also estimated with regard to affected federal regulations, system validation plan, and typical development/installation costs.
SAS- Semantic Annotation Service for Geoscience resources on the web
NASA Astrophysics Data System (ADS)
Elag, M.; Kumar, P.; Marini, L.; Li, R.; Jiang, P.
2015-12-01
There is a growing need for increased integration across the data and model resources that are disseminated on the web to advance their reuse across different earth science applications. Meaningful reuse of resources requires semantic metadata to realize the semantic web vision for allowing pragmatic linkage and integration among resources. Semantic metadata associates standard metadata with resources to turn them into semantically-enabled resources on the web. However, the lack of a common standardized metadata framework as well as the uncoordinated use of metadata fields across different geo-information systems, has led to a situation in which standards and related Standard Names abound. To address this need, we have designed SAS to provide a bridge between the core ontologies required to annotate resources and information systems in order to enable queries and analysis over annotation from a single environment (web). SAS is one of the services that are provided by the Geosematnic framework, which is a decentralized semantic framework to support the integration between models and data and allow semantically heterogeneous to interact with minimum human intervention. Here we present the design of SAS and demonstrate its application for annotating data and models. First we describe how predicates and their attributes are extracted from standards and ingested in the knowledge-base of the Geosemantic framework. Then we illustrate the application of SAS in annotating data managed by SEAD and annotating simulation models that have web interface. SAS is a step in a broader approach to raise the quality of geoscience data and models that are published on the web and allow users to better search, access, and use of the existing resources based on standard vocabularies that are encoded and published using semantic technologies.
Ahmed, Emad; El-Menyar, Ayman
2016-03-01
The South Asian (SA) population constitutes one of the largest ethnic groups in the world. Several studies that compared host and migrant populations around the world indicate that SAs have a higher risk of developing cardiovascular disease (CVD) than their native-born counterparts. Herein, we review the literature to address the role of the screening tools, scoring systems, and guidelines for primary, secondary, and tertiary prevention in these populations. Management based on screening for the CVD risk factors in a high-risk population such as SAs can improve health care outcomes. There are many scoring tools for calculating 10-year CVD risk; however, each scoring system has its limitations in this particular ethnicity. Further work is needed to establish a unique scoring and guidelines in SAs. © The Author(s) 2015.
Crunelle, Cleo L; Veltman, Dick J; Booij, Jan; Emmerik – van Oortmerssen, Katelijne; den Brink, Wim
2012-01-01
Stimulant dependence is associated with neuropsychological impairments. Here, we summarize and integrate the existing neuroimaging literature on the neural substrates of neuropsychological (dys)function in stimulant dependence, including cocaine, (meth-)amphetamine, ecstasy and nicotine dependence, and excessive caffeine use, comparing stimulant abusers (SAs) to nondrug using healthy controls (HCs). Despite some inconsistencies, most studies indicated altered brain activation in prefrontal cortex (PFC) and insula in response to reward and punishment, and higher limbic and anterior cingulate cortex (ACC)/PFC activation during craving and attentional bias paradigms in SAs compared with HCs. Impulsivity in SAs was associated with lower ACC and presupplementary motor area activity compared with HCs, and related to both ventral (amygdala, ventrolateral PFC, insula) and dorsal (dorsolateral PFC, dorsal ACC, posterior parietal cortex) systems. Decision making in SAs was associated with low dorsolateral PFC activity and high orbitofrontal activity. Finally, executive function in SAs was associated with lower activation in frontotemporal regions and higher activation in premotor cortex compared with HCs. It is concluded that the lower activations compared with HCs are likely to reflect the neural substrate of impaired neurocognitive functions, whereas higher activations in SAs compared with HCs are likely to reflect compensatory cognitive control mechanisms to keep behavioral task performance to a similar level as in HCs. However, before final conclusions can be drawn, additional research is needed using neuroimaging in SAs and HCs using larger and more homogeneous samples as well as more comparable task paradigms, study designs, and statistical analyses. PMID:22950052
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Kyo-Sun; Hong, Song You; Yoon, Jin-Ho
2014-10-01
The most recent version of Simplified Arakawa-Schubert (SAS) cumulus scheme in National Center for Environmental Prediction (NCEP) Global Forecast System (GFS) (GFS SAS) has been implemented into the Weather and Research Forecasting (WRF) model with a modification of triggering condition and convective mass flux to become depending on model’s horizontal grid spacing. East Asian Summer Monsoon of 2006 from June to August is selected to evaluate the performance of the modified GFS SAS scheme. Simulated monsoon rainfall with the modified GFS SAS scheme shows better agreement with observation compared to the original GFS SAS scheme. The original GFS SAS schememore » simulates the similar ratio of subgrid-scale precipitation, which is calculated from a cumulus scheme, against total precipitation regardless of model’s horizontal grid spacing. This is counter-intuitive because the portion of resolved clouds in a grid box should be increased as the model grid spacing decreases. This counter-intuitive behavior of the original GFS SAS scheme is alleviated by the modified GFS SAS scheme. Further, three different cumulus schemes (Grell and Freitas, Kain and Fritsch, and Betts-Miller-Janjic) are chosen to investigate the role of a horizontal resolution on simulated monsoon rainfall. The performance of high-resolution modeling is not always enhanced as the spatial resolution becomes higher. Even though improvement of probability density function of rain rate and long wave fluxes by the higher-resolution simulation is robust regardless of a choice of cumulus parameterization scheme, the overall skill score of surface rainfall is not monotonically increasing with spatial resolution.« less
Aglycone solanidine and solasodine derivatives: A natural approach towards cancer.
Hameed, Abdul; Ijaz, Shakeel; Mohammad, Imran Shair; Muhammad, Kiran Sher; Akhtar, Naveed; Khan, Haji Muhammad Shoaib
2017-10-01
Over the past few years, it was suggested that a rational approach to treat cancer in clinical settings requires a multipronged approach that augments improvement in systemic efficiency along with modification in cellular phenotype leads to more efficient cell death response. Recently, the combinatory delivery of traditional chemotherapeutic drugs with natural compounds proved to be astonishing to deal with a variety of cancers, especially that are resistant to chemotherapeutic drugs. The natural compounds not only synergize the effects of chemotherapeutics but also minimize drug associated systemic toxicity. In this review, our primary focus was on antitumor effects of natural compounds. Previously, the drugs from natural sources are highly precise and safer than drugs of synthetic origins. Many natural compounds exhibit anti-cancer potentials by inducing apoptosis in different tumor models, in-vitro and in-vivo. Furthermore, natural compounds are also found equally useful in chemotherapeutic drug resistant tumors. Moreover, these Phyto-compounds also possess numerous other pharmacological properties such as antifungal, antimicrobial, antiprotozoal, and hepatoprotection. Aglycone solasodine and solanidine derivatives are the utmost important steroidal glycoalkaloids that are present in various Solanum species, are discussed here. These natural compounds are highly cytotoxic against different tumor cell lines. As the molecular weight is concerned; these are smaller molecular weight chemotherapeutic agents that induce cell death response by initiating apoptosis through both extrinsic and intrinsic pathways. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Space-based augmentation for global navigation satellite systems.
Grewal, Mohinder S
2012-03-01
This paper describes space-based augmentation for global navigation satellite systems (GNSS). Space-based augmentations increase the accuracy and integrity of the GNSS, thereby enhancing users' safety. The corrections for ephemeris, ionospheric delay, and clocks are calculated from reference station measurements of GNSS data in wide-area master stations and broadcast via geostationary earth orbit (GEO) satellites. This paper discusses the clock models, satellite orbit determination, ionospheric delay estimation, multipath mitigation, and GEO uplink subsystem (GUS) as used in the Wide Area Augmentation System developed by the FAA.
Bahuguna, Rajeev Nayan; Joshi, Rohit; Shukla, Alok; Pandey, Mayank; Kumar, J
2012-08-01
A novel pathogen defense strategy by thiamine priming was evaluated for its efficacy against sheath blight pathogen, Rhizoctonia solani AG-1A, of rice and compared with that of systemic fungicide, carbendazim (BCM). Seeds of semidwarf, high yielding, basmati rice variety Vasumati were treated with thiamine (50 mM) and BCM (4 mM). The pot cultured plants were challenge inoculated with R. solani after 40 days of sowing and effect of thiamine and BCM on rice growth and yield traits was examined. Higher hydrogen peroxide content, total phenolics accumulation, phenylalanine ammonia lyase (PAL) activity and superoxide dismutase (SOD) activity under thiamine treatment displayed elevated level of systemic resistance, which was further augmented under challenging pathogen infection. High transcript level of phenylalanine ammonia lyase (PAL) and manganese superoxide dismutase (MnSOD) validated mode of thiamine primed defense. Though minimum disease severity was observed under BCM treatment, thiamine produced comparable results, with 18.12 per cent lower efficacy. Along with fortifying defense components and minor influence on photosynthetic pigments and nitrate reductase (NR) activity, thiamine treatment significantly reduced pathogen-induced loss in photosynthesis, stomatal conductance, chlorophyll fluorescence, NR activity and NR transcript level. Physiological traits affected under pathogen infection were found signatory for characterizing plant's response under disease and were detectable at early stage of infection. These findings provide a novel paradigm for developing alternative, environmentally safe strategies to control plant diseases. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Güleçyüz, Mehmet F; Kraus-Petersen, Michael; Schröder, Christian; Ficklscherer, Andreas; Wagenhäuser, Markus U; Braun, Christian; Müller, Peter E; Pietschmann, Matthias F
2018-02-01
The incidence of osteoporosis and rotator cuff tears increases with age. Cement augmentation of bones is an established method in orthopedic and trauma surgery. This study analyses if polymethylmethacrylate or bioabsorbable cement can improve the primary stability of a bioabsorbable suture anchor in vitro in comparison to a non-augmented suture anchor in osteoporotic human humeri. The trabecular bone mineral density was measured to ensure osteopenic human specimens. Then the poly-l-lactic acid Bio-Corkscrew® FT was implanted in the greater tuberosity footprint with polymethylmethacrylate Refobacin® cement augmentation ( n = 8), with Cerament™ Bone Void Filler augmentation ( n = 8) and without augmentation ( n = 8). Using a cyclic testing protocol, the failure loads, system displacement, and failure modes were recorded. The Cerament™ augmented Bio-Corkscrew® FT yielded the highest failure loads (206.7 N), followed by polymethylmethacrylate Refobacin® augmentation (206.1 N) and without augmentation (160.0 N). The system displacement was lowest for Cerament™ augmentation (0.72 mm), followed by polymethylmethacrylate (0.82 mm) and without augmentation (1.50 mm). Statistical analysis showed no significant differences regarding the maximum failure loads ( p = 0.1644) or system displacement ( p = 0.4199). The main mode of failure for all three groups was suture slippage. The primary stability of the Bio-Corkscrew® FT is not influenced by bone cement augmentation with polymethylmethacrylate Refobacin® or with bioabsorbable Cerament™ in comparison to the non-cemented anchors. The cement augmentation of rotator cuff suture anchors in osteoporotic bones remains questionable since biomechanical tests show no significant advantage.
Duron, J-B; Nguyen, P S; Levet, Y; Bardot, J; Aiach, G
2014-12-01
Overprojected tip is a pretty usual request not easy to manage. Preop analysis is crucial in order to evaluate tip support and skin thickness and ability to retract. For example, if the skin is very thick and has poor chance to retract, the surgeon should be very careful in the tip projection decreasing to avoid a skin pollybeak deformity. In such cases, he has to analyze the facial proportions, especially other areas projection (radix, dorsum and chin) and think about augmenting them to balance the profile rather than decreasing tip projection. Correction should always be conducted incrementally, starting with weakening the tip support mechanisms and, only if necessary, continue with alar cartilage interruption. This can be performed on many areas (lateral cruras, domes, medial cruras) and with several techniques (resection or interruption+overlapping). Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Performance Assessment of a Large Scale Pulsejet- Driven Ejector System
NASA Technical Reports Server (NTRS)
Paxson, Daniel E.; Litke, Paul J.; Schauer, Frederick R.; Bradley, Royce P.; Hoke, John L.
2006-01-01
Unsteady thrust augmentation was measured on a large scale driver/ejector system. A 72 in. long, 6.5 in. diameter, 100 lb(sub f) pulsejet was tested with a series of straight, cylindrical ejectors of varying length, and diameter. A tapered ejector configuration of varying length was also tested. The objectives of the testing were to determine the dimensions of the ejectors which maximize thrust augmentation, and to compare the dimensions and augmentation levels so obtained with those of other, similarly maximized, but smaller scale systems on which much of the recent unsteady ejector thrust augmentation studies have been performed. An augmentation level of 1.71 was achieved with the cylindrical ejector configuration and 1.81 with the tapered ejector configuration. These levels are consistent with, but slightly lower than the highest levels achieved with the smaller systems. The ejector diameter yielding maximum augmentation was 2.46 times the diameter of the pulsejet. This ratio closely matches those of the small scale experiments. For the straight ejector, the length yielding maximum augmentation was 10 times the diameter of the pulsejet. This was also nearly the same as the small scale experiments. Testing procedures are described, as are the parametric variations in ejector geometry. Results are discussed in terms of their implications for general scaling of pulsed thrust ejector systems
Virtual and Augmented Reality Systems for Renal Interventions: A Systematic Review.
Detmer, Felicitas J; Hettig, Julian; Schindele, Daniel; Schostak, Martin; Hansen, Christian
2017-01-01
Many virtual and augmented reality systems have been proposed to support renal interventions. This paper reviews such systems employed in the treatment of renal cell carcinoma and renal stones. A systematic literature search was performed. Inclusion criteria were virtual and augmented reality systems for radical or partial nephrectomy and renal stone treatment, excluding systems solely developed or evaluated for training purposes. In total, 52 research papers were identified and analyzed. Most of the identified literature (87%) deals with systems for renal cell carcinoma treatment. About 44% of the systems have already been employed in clinical practice, but only 20% in studies with ten or more patients. Main challenges remaining for future research include the consideration of organ movement and deformation, human factor issues, and the conduction of large clinical studies. Augmented and virtual reality systems have the potential to improve safety and outcomes of renal interventions. In the last ten years, many technical advances have led to more sophisticated systems, which are already applied in clinical practice. Further research is required to cope with current limitations of virtual and augmented reality assistance in clinical environments.
Carrier Air Wing Tactics Incorporating Navy Unmanned Combat Air System (NUCAS)
2010-03-01
Profile Curves of Mean Target Casualty Rate Versus GBU-31 Phit and NUCAS Sensor Aperture (After SAS Institute, 2010...Prediction Profile Curve of Mean Blue Survivability Percent Versus AIM- 120 Weapons Phit (After SAS Institute, 2010...Weapons Phit is a major factor in target destruction and blue survivability. Our approach shows how simulation, data farming techniques, and data
Augmented reality in neurovascular surgery: feasibility and first uses in the operating room.
Kersten-Oertel, Marta; Gerard, Ian; Drouin, Simon; Mok, Kelvin; Sirhan, Denis; Sinclair, David S; Collins, D Louis
2015-11-01
The aim of this report is to present a prototype augmented reality (AR) intra-operative brain imaging system. We present our experience of using this new neuronavigation system in neurovascular surgery and discuss the feasibility of this technology for aneurysms, arteriovenous malformations (AVMs), and arteriovenous fistulae (AVFs). We developed an augmented reality system that uses an external camera to capture the live view of the patient on the operating room table and to merge this view with pre-operative volume-rendered vessels. We have extensively tested the system in the laboratory and have used the system in four surgical cases: one aneurysm, two AVMs and one AVF case. The developed AR neuronavigation system allows for precise patient-to-image registration and calibration of the camera, resulting in a well-aligned augmented reality view. Initial results suggest that augmented reality is useful for tailoring craniotomies, localizing vessels of interest, and planning resection corridors. Augmented reality is a promising technology for neurovascular surgery. However, for more complex anomalies such as AVMs and AVFs, better visualization techniques that allow one to distinguish between arteries and veins and determine the absolute depth of a vessel of interest are needed.
Augmented reality based real-time subcutaneous vein imaging system
Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian
2016-01-01
A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed. PMID:27446690
Augmented reality based real-time subcutaneous vein imaging system.
Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian
2016-07-01
A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.
NASA Astrophysics Data System (ADS)
Tsujii, Toshiaki; Harigae, Masatoshi
Recently, some feasibility studies on a regional positioning system using the quasi-zenith satellites and the geostationary satellites have been conducted in Japan. However, the geometry of this system seems to be unsatisfactory in terms of the positioning accuracy in north-south direction. In this paper, an augmented satellite positioning system by the High Altitude Platform Systems (HAPS) is proposed since the flexibility of the HAPS location is effective to improve the geometry of satellite positioning system. The improved positioning performance of the augmented system is also demonstrated.
Data management system for USGS/USEPA urban hydrology studies program
Doyle, W.H.; Lorens, J.A.
1982-01-01
A data management system was developed to store, update, and retrieve data collected in urban stormwater studies jointly conducted by the U.S. Geological Survey and U.S. Environmental Protection Agency in 11 cities in the United States. The data management system is used to retrieve and combine data from USGS data files for use in rainfall, runoff, and water-quality models and for data computations such as storm loads. The system is based on the data management aspect of the Statistical Analysis System (SAS) and was used to create all the data files in the data base. SAS is used for storage and retrieval of basin physiography, land-use, and environmental practices inventory data. Also, storm-event water-quality characteristics are stored in the data base. The advantages of using SAS to create and manage a data base are many with a few being that it is simple, easy to use, contains a comprehensive statistical package, and can be used to modify files very easily. Data base system development has progressed rapidly during the last two decades and the data managment system concepts used in this study reflect the advancement made in computer technology during this era. Urban stormwater data is, however, just one application for which the system can be used. (USGS)
From Augmentation Media to Meme Media.
ERIC Educational Resources Information Center
Tanaka, Yuzuru
Computers as meta media are now evolving from augmentation media vehicles to meme media vehicles. While an augmentation media system provides a seamlessly integrated environment of various tools and documents, meme media system provides further functions to edit and distribute tools and documents. Documents and tools on meme media can easily…
Lefèvre-Dognin, C; Stana, L; Jousse, M; Lucas, C; Sportouch, P; Bradai, N; Guettard, E; Vicaut, E; Yelnik, A P
2014-12-01
Sleep apnea syndrome (SAS) frequently occurs after a stroke. Its association with a poor prognosis is open to discussion. To study, in a physical and rehabilitation medicine (PRM) unit, the possible repercussions of SAS on neurological and functional recovery as well as attentional abilities following a stroke. Forty-five patients, all of whom had recently had a stroke without previously documented SAS, were screened using the ApneaLink(®) system. An apnea-hypopnea index (AHI) score ≥10 was considered as indicative of SAS. The NIHSS, Fugl-Meyer (FM) and Functional Independence Measure (FIM) Scales were applied on admission and at two months as means of assessing neurological and functional recovery, which was expressed by the difference between the first and the second scores (delta FM, delta NIHSS, delta FIM). The Battery Attention William Lennox (BAWL) Test was given once in order to evaluate attention disorders. SAS severity was categorized according to the AHI. We compared the groups formed (mild, moderate and severe) using the same method. Twenty-eight patients (62.2%) presented AHI ≥ 10. Stroke characteristics were comparable in the SAS+ and the SAS- groups, with average post-stroke time lapse of 26 days, initial average FIM score of 71.2 points ± 26.3 and initial average NIHSS score of 8.9 ± 4.9. The demographic characteristics of the two groups were likewise comparable with the exception of age, as the SAS+ group was pronouncedly older (65.4 vs. 53.5 years). As for delta FIM, which evaluated functional recovery, it averaged 31.8 ± 20.6. Cases of SAS were found to be mild (37.1%), moderate (28.6%) or severe (34.3%). No significant difference was observed on admission or at 2 months as regards the clinical scales or the BAWL test between the two groups or according to severity, except for the NIHSS score at 2 months in the severe sub-group. This study did not demonstrate the supposed repercussions of SAS on the recovery or attentional abilities of post-stroke patients. The tests were maybe given too early; they should take place at a lengthier time interval after the stroke, and also to be more complete. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Zhu, Ming; Liu, Fei; Chai, Gang; Pan, Jun J.; Jiang, Taoran; Lin, Li; Xin, Yu; Zhang, Yan; Li, Qingfeng
2017-01-01
Augmented reality systems can combine virtual images with a real environment to ensure accurate surgery with lower risk. This study aimed to develop a novel registration and tracking technique to establish a navigation system based on augmented reality for maxillofacial surgery. Specifically, a virtual image is reconstructed from CT data using 3D software. The real environment is tracked by the augmented reality (AR) software. The novel registration strategy that we created uses an occlusal splint compounded with a fiducial marker (OSM) to establish a relationship between the virtual image and the real object. After the fiducial marker is recognized, the virtual image is superimposed onto the real environment, forming the “integrated image” on semi-transparent glass. Via the registration process, the integral image, which combines the virtual image with the real scene, is successfully presented on the semi-transparent helmet. The position error of this navigation system is 0.96 ± 0.51 mm. This augmented reality system was applied in the clinic and good surgical outcomes were obtained. The augmented reality system that we established for maxillofacial surgery has the advantages of easy manipulation and high accuracy, which can improve surgical outcomes. Thus, this system exhibits significant potential in clinical applications. PMID:28198442
Zhu, Ming; Liu, Fei; Chai, Gang; Pan, Jun J; Jiang, Taoran; Lin, Li; Xin, Yu; Zhang, Yan; Li, Qingfeng
2017-02-15
Augmented reality systems can combine virtual images with a real environment to ensure accurate surgery with lower risk. This study aimed to develop a novel registration and tracking technique to establish a navigation system based on augmented reality for maxillofacial surgery. Specifically, a virtual image is reconstructed from CT data using 3D software. The real environment is tracked by the augmented reality (AR) software. The novel registration strategy that we created uses an occlusal splint compounded with a fiducial marker (OSM) to establish a relationship between the virtual image and the real object. After the fiducial marker is recognized, the virtual image is superimposed onto the real environment, forming the "integrated image" on semi-transparent glass. Via the registration process, the integral image, which combines the virtual image with the real scene, is successfully presented on the semi-transparent helmet. The position error of this navigation system is 0.96 ± 0.51 mm. This augmented reality system was applied in the clinic and good surgical outcomes were obtained. The augmented reality system that we established for maxillofacial surgery has the advantages of easy manipulation and high accuracy, which can improve surgical outcomes. Thus, this system exhibits significant potential in clinical applications.
Human Augmentics: augmenting human evolution.
Kenyon, Robert V; Leigh, Jason
2011-01-01
Human Augmentics (HA) refers to technologies for expanding the capabilities, and characteristics of humans. One can think of Human Augmentics as the driving force in the non-biological evolution of humans. HA devices will provide technology to compensate for human biological limitations either natural or acquired. The strengths of HA lie in its applicability to all humans. Its interoperability enables the formation of ecosystems whereby augmented humans can draw from other realms such as "the Cloud" and other augmented humans for strength. The exponential growth in new technologies portends such a system but must be designed for interaction through the use of open-standards and open-APIs for system development. We discuss the conditions needed for HA to flourish with an emphasis on devices that provide non-biological rehabilitation.
Situation awareness system for Canada
NASA Astrophysics Data System (ADS)
Hill, Andrew
1999-07-01
Situation awareness encompasses a knowledge of orders, plans and current knowledge of friendly force actions. Knowing where you are and being able to transmit that information in near real-time to other friendly forces provides the ability to exercise precise command and control over those forces. With respect to current command and control using voice methods, between 40 percent and 60 percent of Combat Net Radio traffic relates to location reporting of some sort. Commanders at Battle Group and below spend, on average, 40 percent of their total time performing position and navigation related functions. The need to rapidly transfer own force location information throughout a force and to process the received information quickly, accurately and reliably provides the rationale for the requirement for an automated situation awareness system. This paper describes the Situation Awareness System (SAS) being developed by Computing Devices Canada for the Canadian Department of National Defence as a component of the Position Determination and Navigation for Land Forces program. The SAS is being integrated with the Iris Tactical Command, Control, Communications System, which is also being developed by Computing Devices. The SAS software provides a core operating environment onto which command and control functionality can be easily added to produce general and specialist battlefield management systems.
Theoretical Investigations on the Efficiency and the Conditions for the Realization of Jet Engines
NASA Technical Reports Server (NTRS)
Roy, Maurice
1950-01-01
Contents: Preliminary notes on the efficiency of propulsion systems; Part I: Propulsion systems with direct axial reaction rockets and rockets with thrust augmentation; Part II: Helicoidal reaction propulsion systems; Appendix I: Steady flow of viscous gases; Appendix II: On the theory of viscous fluids in nozzles; and Appendix III: On the thrusts augmenters, and particularly of gas augmenters
A Solar Aspect System for the HEROES Mission
NASA Technical Reports Server (NTRS)
Christe, Steven; Shih, Albert; Rodriguez, Marcello; Gregory, Kyle; Cramer, Alexander; Edgerton, Melissa; Gaskin, Jessica; O'Connor, Brian; Sobey, Alexander
2014-01-01
A new Solar Aspect System (SAS) has been developed to provide the ability to observe the Sun on an existing balloon payload HERO (short for High Energy Replicated Optics). Developed under the HEROES program (High Energy Replicated Optics to Explore the Sun), the SAS aspect system provides solar pointing knowledge in pitch, yaw, and roll. The required precision of these measurements must be better than the HEROES X-ray resolution of approximately 20 arcsec Full Width at Half Maximum (FWHM) so as to not degrade the image resolution. The SAS consists of two separate systems: the Pitch-Yaw Aspect System (PYAS) and the Roll Aspect System (RAS). The PYAS functions by projecting an image of the Sun onto a screen with precision fiducials. A CCD camera takes an image of these fiducials, and an automated algorithm determines the location of the Sun as well as the location of the fiducials. The spacing between fiducials is unique and allows each to be identified so that the location of the Sun on the screen can be precisely determined. The RAS functions by imaging the Earth's horizon in opposite directions using a silvered prism imaged by a CCD camera. The design and first results of the performance of these systems during the HEROES flight which occurred in September 2013 are presented here.
NASA Astrophysics Data System (ADS)
Cuellar Martinez, A.; Espinosa Aranda, J.; Suarez, G.; Ibarrola Alvarez, G.; Ramos Perez, S.; Camarillo Barranco, L.
2013-05-01
The Seismic Alert System of Mexico (SASMEX) uses three algorithms for alert activation that involve the distance between the seismic sensing field station (FS) and the city to be alerted; and the forecast for earthquake early warning activation in the cities integrated to the system, for example in Mexico City, the earthquakes occurred with the highest accelerations, were originated in the Pacific Ocean coast, whose distance this seismic region and the city, favors the use of algorithm called Algorithm SAS-I. This algorithm, without significant changes since its beginning in 1991, employs the data that generate one or more FS during P wave detection until S wave detection plus a period equal to the time employed to detect these phases; that is the double S-P time, called 2*(S-P). In this interval, the algorithm performs an integration process of quadratic samples from FS which uses a triaxial accelerometer to get two parameters: amplitude and growth rate measured until 2*(S-P) time. The parameters in SAS-I are used in a Magnitude classifier model, which was made from Guerrero Coast earthquakes time series, with reference to Mb magnitude mainly. This algorithm activates a Public or Preventive Alert if the model predicts whether Strong or Moderate earthquake. The SAS-I algorithm has been operating for over 23 years in the subduction zone of the Pacific Coast of Mexico, initially in Guerrero and followed by Oaxaca; and since March 2012 in the seismic region of Pacific covering the coasts among Jalisco, Colima, Michoacan, Guerrero and Oaxaca, where this algorithm has issued 16 Public Alert and 62 Preventive Alerts to the Mexico City where its soil conditions increase damages by earthquake such as the occurred in September 1985. This work shows the review of the SAS-I algorithm and possible alerts that it could generate from major earthquakes recordings detected by FS or seismometers near the earthquakes, coming from Pacific Ocean Coast whose have been felt in Mexico City, in order to observe the performance SAS-I algorithm.
Augmentation of Cognition and Perception Through Advanced Synthetic Vision Technology
NASA Technical Reports Server (NTRS)
Prinzel, Lawrence J., III; Kramer, Lynda J.; Bailey, Randall E.; Arthur, Jarvis J.; Williams, Steve P.; McNabb, Jennifer
2005-01-01
Synthetic Vision System technology augments reality and creates a virtual visual meteorological condition that extends a pilot's cognitive and perceptual capabilities during flight operations when outside visibility is restricted. The paper describes the NASA Synthetic Vision System for commercial aviation with an emphasis on how the technology achieves Augmented Cognition objectives.
NASA Technical Reports Server (NTRS)
Farhangi, Shahram; Trent, Donnie (Editor)
1992-01-01
A study was directed towards assessing viability and effectiveness of an air augmented ejector/rocket. Successful thrust augmentation could potentially reduce a multi-stage vehicle to a single stage-to-orbit vehicle (SSTO) and, thereby, eliminate the associated ground support facility infrastructure and ground processing required by the eliminated stage. The results of this preliminary study indicate that an air augmented ejector/rocket propulsion system is viable. However, uncertainties resulting from simplified approach and assumptions must be resolved by further investigations.
NASA Technical Reports Server (NTRS)
Mcgee, L. A.; Smith, G. L.; Hegarty, D. M.; Merrick, R. B.; Carson, T. M.; Schmidt, S. F.
1970-01-01
A preliminary study has been made of the navigation performance which might be achieved for the high cross-range space shuttle orbiter during final approach and landing by using an optimally augmented inertial navigation system. Computed navigation accuracies are presented for an on-board inertial navigation system augmented (by means of an optimal filter algorithm) with data from two different ground navigation aids; a precision ranging system and a microwave scanning beam landing guidance system. These results show that augmentation with either type of ground navigation aid is capable of providing a navigation performance at touchdown which should be adequate for the space shuttle. In addition, adequate navigation performance for space shuttle landing is obtainable from the precision ranging system even with a complete dropout of precision range measurements as much as 100 seconds before touchdown.
National Airspace System : observations on the wide area augmentation system
DOT National Transportation Integrated Search
1997-10-01
This congressional testimony by Gerald L. Dillingham, Associate Director, : Transportation Issues Resources, Community, and Economic Development Division : discusses the Federal Aviation Administration's (FAA) Wide Area Augmentation : System (WAAS) p...
[Display technologies for augmented reality in medical applications].
Eck, Ulrich; Winkler, Alexander
2018-04-01
One of the main challenges for modern surgery is the effective use of the many available imaging modalities and diagnostic methods. Augmented reality systems can be used in the future to blend patient and planning information into the view of surgeons, which can improve the efficiency and safety of interventions. In this article we present five visualization methods to integrate augmented reality displays into medical procedures and the advantages and disadvantages are explained. Based on an extensive literature review the various existing approaches for integration of augmented reality displays into medical procedures are divided into five categories and the most important research results for each approach are presented. A large number of mixed and augmented reality solutions for medical interventions have been developed as research prototypes; however, only very few systems have been tested on patients. In order to integrate mixed and augmented reality displays into medical practice, highly specialized solutions need to be developed. Such systems must comply with the requirements with respect to accuracy, fidelity, ergonomics and seamless integration into the surgical workflow.
Moneghini, M; Perissutti, B; Kikic, I; Grassi, M; Cortesi, A; Princivalle, F
2006-01-01
Several controlled release systems of drugs have been elaborated using a supercritical fluid process. Indeed, recent techniques using a supercritical fluid as a solvent or as an antisolvent are considered to be useful alternatives to produce fine powders. In this preliminary study, the effect of Supercritical Anti Solvent process (SAS) on the release of theophylline from matrices manufactured with hydroxypropylmethylcellulose (HPMC) was investigated. Two grades of HPMC (HPMC E5 and K100) as carriers were considered in order to prepare a sustained delivery system for theophylline which was used as a model drug. The characterization of the drug before and after SAS treatment, and the coprecipitates with carriers, was performed by X-ray Diffraction (XRD) and Differential Scanning Calorimetry (DSC). The dissolution rate of theophylline, theophylline-coprecipitates, and matricial tablets prepared with coprecipitates were determined. The physical characterizations revealed a substantial correspondence of the drug solid state before and after supercritical fluid treatment while drug-polymer interactions in the SAS-coprecipitates were attested. The dissolution studies of the matrices prepared compressing the coprecipitated systems showed that the matrices based on HPMC K100 were able to promote a sustained release of the drug. Further, this advantageous dissolution performance was found to be substantially independent of the pH of the medium. The comparison with the matrices prepared with untreated substances demonstrated that matrices obtained with SAS technique can provide a slower theophylline release rate. A new mathematical model describing the in vitro dissolution kinetics was proposed and successfully tested on these systems.
Cranial implant design using augmented reality immersive system.
Ai, Zhuming; Evenhouse, Ray; Leigh, Jason; Charbel, Fady; Rasmussen, Mary
2007-01-01
Software tools that utilize haptics for sculpting precise fitting cranial implants are utilized in an augmented reality immersive system to create a virtual working environment for the modelers. The virtual environment is designed to mimic the traditional working environment as closely as possible, providing more functionality for the users. The implant design process uses patient CT data of a defective area. This volumetric data is displayed in an implant modeling tele-immersive augmented reality system where the modeler can build a patient specific implant that precisely fits the defect. To mimic the traditional sculpting workspace, the implant modeling augmented reality system includes stereo vision, viewer centered perspective, sense of touch, and collaboration. To achieve optimized performance, this system includes a dual-processor PC, fast volume rendering with three-dimensional texture mapping, the fast haptic rendering algorithm, and a multi-threading architecture. The system replaces the expensive and time consuming traditional sculpting steps such as physical sculpting, mold making, and defect stereolithography. This augmented reality system is part of a comprehensive tele-immersive system that includes a conference-room-sized system for tele-immersive small group consultation and an inexpensive, easily deployable networked desktop virtual reality system for surgical consultation, evaluation and collaboration. This system has been used to design patient-specific cranial implants with precise fit.
NASA Astrophysics Data System (ADS)
Wu, Jiang; Liao, Fucheng; Tomizuka, Masayoshi
2017-01-01
This paper discusses the design of the optimal preview controller for a linear continuous-time stochastic control system in finite-time horizon, using the method of augmented error system. First, an assistant system is introduced for state shifting. Then, in order to overcome the difficulty of the state equation of the stochastic control system being unable to be differentiated because of Brownian motion, the integrator is introduced. Thus, the augmented error system which contains the integrator vector, control input, reference signal, error vector and state of the system is reconstructed. This leads to the tracking problem of the optimal preview control of the linear stochastic control system being transformed into the optimal output tracking problem of the augmented error system. With the method of dynamic programming in the theory of stochastic control, the optimal controller with previewable signals of the augmented error system being equal to the controller of the original system is obtained. Finally, numerical simulations show the effectiveness of the controller.
Venkatachalam, P; Jayaraj, M; Manikandan, R; Geetha, N; Rene, Eldon R; Sharma, N C; Sahi, S V
2017-01-01
The present study describes the role of zinc oxide nanoparticles (ZnONPs) in reversing oxidative stress symptoms induced by heavy metal (Cd and Pb) exposure in Leucaena leucocephala (Lam.) de Wit. Seedling growth was significantly enhanced with the augmentation of ZnONPs following Cd and Pb exposure. Heavy metal accumulations were recorded as 1253.1 mg Cd per kg DW and 1026.8 mg Pb per kg DW for the respective treatments. Results demonstrated that ZnONPs augmentation caused an increase in photosynthetic pigment and total soluble protein contents while a significant decrease in malondialdehyde (MDA-lipid peroxidation) content in leaves. Antioxidative enzymes such as superoxide dismutase (SOD), catalase (CAT) and peroxidase (POX) were, in turn, elevated in heavy metal-exposed leaves amended with ZnONPs. The ameliorating effect of ZnO nanoparticles on oxidative stress induced toxicity was also confirmed by the reduced MDA content and the elevated level of antioxidative enzyme activities in leaf tissues of L. leucocephala seedlings. Further, addition of ZnONPs in combination with Cd and Pb metals induced distinct genomic alterations such as presence of new DNA bands and/or absence of normal bands in the RAPD pattern of the exposed plants. This study uniquely suggests a potential role of zinc oxide nanoparticles in the remediation of heavy metal contaminated media. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
CVD silicon carbide monofilament reinforced SrO-Al2O3-2SiO2 (SAS) glass-ceramic composites
NASA Technical Reports Server (NTRS)
Bansal, Narottam P.
1995-01-01
Unidirectional CVD SiC fiber-reinforced SrO.Al2O3.2SiO2 (SAS) glass-ceramic matrix composites have been fabricated by hot pressing at various combinations of temperature, pressure and time. Both carbon-rich surface coated SCS-6 and uncoated SCS-0 fibers were used as reinforcements. Almost fully dense composites have been obtained. Monoclinic celsian, SrAl2Si2O8, was the only crystalline phase observed in the matrix from x-ray diffraction. During three point flexure testing of composites, a test span to thickness ratio of approximately 25 or greater was necessary to avoid sample delamination. Strong and tough SCS-6/SAS composites having a first matrix crack stress of approximately 300 MPa and an ultimate bend strength of approximately 825 MPa were fabricated. No chemical reaction between the SCS-6 fibers and the SAS matrix was observed after high temperature processing. The uncoated SCS-0 fiber-reinforced SAS composites showed only limited improvement in strength over SAS monolithic. The SCS-0/SAS composite having a fiber volume fraction of 0.24 and hot pressed at 1400 deg C exhibited a first matrix cracking stress of approximately 231 +/- 20 MPa and ultimate strength of 265 +/- 17 MPa. From fiber push-out tests, the fiber/matrix interfacial debonding strength (tau(sub debond)) and frictional sliding stress (tau(sub friction)) in the SCS-6/SAS system were evaluated to be approximately 6.7 +/- 2.3 MPa and 4.3 +/- 0.6 MPa, respectively, indicating a weak interface. However, for the SCS-0/SAS composite, much higher values of approximately 17.5 +/- 2.7 MPa for tau(sub debond) and 11.3 +/- 1.6 MPa for tau(sub friction) respectively, were observed; some of the fibers were so strongly bonded to the matrix that they could not be pushed out. Examination of fracture surfaces revealed limited short pull-out length of SCS-0 fibers. The applicability of various micromechanical models for predicting the values of first matrix cracking stress and ultimate strength of these composites were examined.
NASA Astrophysics Data System (ADS)
Kim, Seoksoo; Jung, Sungmo; Song, Jae-Gu; Kang, Byong-Ho
As augmented reality and a gravity sensor is of growing interest, siginificant developement is being made on related technology, which allows application of the technology in a variety of areas with greater expectations. In applying Context-aware to augmented reality, it can make useful programs. A traning system suggested in this study helps a user to understand an effcienct training method using augmented reality and make sure if his exercise is being done propery based on the data collected by a gravity sensor. Therefore, this research aims to suggest an efficient training environment that can enhance previous training methods by applying augmented reality and a gravity sensor.
Architecture and Key Techniques of Augmented Reality Maintenance Guiding System for Civil Aircrafts
NASA Astrophysics Data System (ADS)
hong, Zhou; Wenhua, Lu
2017-01-01
Augmented reality technology is introduced into the maintenance related field for strengthened information in real-world scenarios through integration of virtual assistant maintenance information with real-world scenarios. This can lower the difficulty of maintenance, reduce maintenance errors, and improve the maintenance efficiency and quality of civil aviation crews. Architecture of augmented reality virtual maintenance guiding system is proposed on the basis of introducing the definition of augmented reality and analyzing the characteristics of augmented reality virtual maintenance. Key techniques involved, such as standardization and organization of maintenance data, 3D registration, modeling of maintenance guidance information and virtual maintenance man-machine interaction, are elaborated emphatically, and solutions are given.
A Practical Guide To Solar Array Simulation And PCDU Test
NASA Astrophysics Data System (ADS)
Schmitz, Noah; Carroll, Greg; Clegg, Russell
2011-10-01
Solar arrays consisting of multiple photovoltaic segments provide power to satellites and charge internal batteries for use during eclipse. Solar arrays have unique I-V characteristics and output power which vary with environmental and operational conditions such as temperature, irradiance, spin, and eclipse. Therefore, specialty power solutions are needed to properly test the satellite on the ground, especially the Power Control and Distribution Unit (PCDU) and the Array Power Regulator (APR.) This paper explores some practical and theoretical considerations that should be taken into account when choosing a commercial, off-the-shelf solar array simulator (SAS) for verification of the satellite PCDU. An SAS is a unique power supply with I-V output characteristics that emulate the solar arrays used to power a satellite. It is important to think about the strengths and the limitations of this emulation capability, how closely the SAS approximates a real solar panel, and how best to design a system using SAS as components.
Kenig, Jakub; Mastalerz, Kinga; Mitus, Jerzy; Kapelanczyk, Agata
2018-05-30
Frailty increases the risk of poor surgical outcomes in the older population. Some measurable intraoperative factors may also influence the final outcome. The Surgical Apgar Score (SAS) is a simple system predicting postoperative mortality and morbidity. However, the usefulness of the SAS remains unknown in fit and frail older patients. We aimed to test this, as well as investigate whether SAS can increase the predictive value of frailty in this group of patients. Consecutive patients ≥70 years of age, needing elective abdominal surgery for cancer were enrolled in a prospective study. Comprehensive Geriatric Assessment was used to determine frailty. Logistic regression was conducted investigating the association between the scores and 30-day postoperative outcomes and 1-year mortality. The study included 165 older patients with a median age of 77 (range 70-93) years. The prevalence of frailty was 38.2%. The most significant predictors of short-term morbidity and mortality were frailty [OR 6.2 (95%CI 2.9-13.4) and 14.9 (95%CI 5.9-38)] and the SAS [OR 12.5 (95%CI 2.8-45) and 29.5 (95%CI 6.3-125)]. At long-term follow-up frailty was the best predictor of mortality: OR 4.6 (95%CI 1.8-17.6). Frailty and the SAS, not age, were significant predictors of 30-day postoperative morbidity and mortality both in fit and frail older patients undergoing elective abdominal cancer surgery. At 1-yearfollow-up frailty, not the SAS, was an independent risk factor of mortality. The combination of frailty and the SAS increased predictive accuracy and may be a target of care. Copyright © 2018 Elsevier Inc. All rights reserved.
Osada, Shigehiro; Sutton, Ann; Muster, Nemone; Brown, Christine E.; Yates, John R.; Sternglanz, Rolf; Workman, Jerry L.
2001-01-01
It is well established that acetylation of histone and nonhistone proteins is intimately linked to transcriptional activation. However, loss of acetyltransferase activity has also been shown to cause silencing defects, implicating acetylation in gene silencing. The something about silencing (Sas) 2 protein of Saccharomyces cerevisiae, a member of the MYST (MOZ, Ybf2/Sas3, Sas2, and TIP60) acetyltransferase family, promotes silencing at HML and telomeres. Here we identify a ∼450-kD SAS complex containing Sas2p, Sas4p, and the tf2f-related Sas5 protein. Mutations in the conserved acetyl-CoA binding motif of Sas2p are shown to disrupt the ability of Sas2p to mediate the silencing at HML and telomeres, providing evidence for an important role for the acetyltransferase activity of the SAS complex in silencing. Furthermore, the SAS complex is found to interact with chromatin assembly factor Asf1p, and asf1 mutants show silencing defects similar to mutants in the SAS complex. Thus, ASF1-dependent chromatin assembly may mediate the role of the SAS complex in silencing. PMID:11731479
Won, Dong-Han; Kim, Min-Soo; Lee, Sibeum; Park, Jeong-Sook; Hwang, Sung-Joo
2005-09-14
Solid dispersions of felodipine were formulated with HPMC and surfactants by the conventional solvent evaporation (CSE) and supercritical anti-solvent precipitation (SAS) methods. The solid dispersion particles were characterized by particle size, zeta potential, scanning electron microscopy (SEM), differential scanning calorimetry (DSC), powder X-ray diffraction (XRD), solubility and dissolution studies. The effects of the drug/polymer ratio and surfactants on the solubility of felodipine were also studied. The mean particle size of the solid dispersions was 200-250 nm; these had a relatively regular spherical shape with a narrow size distribution. The particle size of the solid dispersions from the CSE method increased at 1 h after dispersed in distilled water. However, the particle sizes of solid dispersions from the SAS process were maintained for 6 h due to the increased solubility of felodipine. The physical state of felodipine changed from crystalline to amorphous during the CSE and SAS processes, confirmed by DSC/XRD data. The equilibrium solubility of the felodipine solid dispersion prepared by the SAS process was 1.5-20 microg/ml, while the maximum solubility was 35-110 microg/ml. Moreover, the solubility of felodipine increased with decreasing drug/polymer ratio or increasing HCO-60 content. The solid dispersions from the SAS process showed a high dissolution rate of over 90% within 2 h. The SAS process system may be used to enhance solubility or to produce oral dosage forms with high dissolution rate.
Flight Performance of the HEROES Solar Aspect System
NASA Astrophysics Data System (ADS)
Shih, Albert Y.; Christe, Steven; Rodriguez, Marcello; Gregory, Kyle; Cramer, Alexander; Edgerton, Melissa; Gaskin, Jessica; O'Connor, Brian; Sobey, Alexander
2014-06-01
Hard X-ray (HXR) observations of solar flares reveal the signatures of energetic electrons, and HXR images with high dynamic range and high sensitivity can distinguish between where electrons are accelerated and where they stop. Furthermore, high-sensitivity HXR measurements may be able to detect the presence of electron acceleration in the non-flaring corona. The High Energy Replicated Optics to Explore the Sun (HEROES) balloon mission added the capability of solar observations to an existing astrophysics balloon payload, HERO, which used grazing-incidence optics for direct HXR imaging. The HEROES Solar Aspect System (SAS) was developed and built to provide pointing knowledge during solar observations to better than the ~20 arcsec FWHM angular resolution of the HXR instrument. The SAS consists of two separate systems: the Pitch-Yaw aspect System (PYAS) and the Roll Aspect System (RAS). The PYAS compares the position of an optical image of the Sun relative to precise fiducials to determine the pitch and yaw pointing offsets from the desired solar target. The RAS images the Earth's horizon in opposite directions simultaneously to determine the roll of the gondola. HEROES launched in September 2013 from Fort Sumner, New Mexico, and had a successful one-day flight. We present the detailed analysis of the performance of the SAS for that flight.
Li, Xin; Cai, Wenwu; Zhang, Ping; Fang, Kun; Zhu, Jieting; Shu, Chang
2018-05-18
Patients with Stanford B aortic dissection usually complicated with sleep apnea syndrome. This condition always threatens the patients' respiration situation. In this study, we collected and analysis data of patients' peri-operative managements of Thoracic Endovascular Aortic Repair (TEVAR) for Stanford B Aortic Dissection (AD) complicated with Sleep Apnea Syndrome (SAS). Comparison has been made between these SAS patients and those who without SAS. Between June 2013 and June 2014, the clinical data and outcomes of the Stanford B AD patients in the department of vascular surgery in the Second Xiangya Hospital were retrospectively reviewed and studied. According to the result of intentionally polysomonography by using portable Polysomnography monitor (Nox T3, Nox Medical Co. Iceland) in TEVAR candidates, patients has been divided to SAS positive and SAS negative group. Comparison has been made in various variables between these two groups. 134 patients, with Stanford B AD and treated by TEVAR in our center, were enrolled in this study. Patients' mean age was 52.46±10.84 years old. Gender ratio is 114:20, including male 85.07% (114/134) and female 14.93% (20/134). 71.64% (96/134) patients had been performed TEVAR under general anesthesia (GA) and 38 patients were under local anesthesia (LA).The mean body mass index (BMI) was 23.5±4.2, and the longest follow-up time was 46 months. The patients were divided into SAS-positive group (n=23) and SAS-negative group (n=111). Compared with the SAS-negative group, patients in the SAS-positive group were younger (54.36±0.97 vs 43.3±1.84 p<0.0001) but in higher BMI (25.48±0.71 vs 22.24±0.23, p<0.0001 ), with longer hospitalization time (25.52±0.59 vs 15.68±0.27; p<0.0001) but without significant differences of ICU stay time (54.87±12.57 vs 40.27±8.10; p=0.3369). Furthermore, the complication rate of both pulmonary infection (65.22% vs 13.51%; p<0.0001), respiratory failure (26.09% vs 1.80%; p=0.003), heart failure ( 26.09% vs 3.60%; p=0.0018) and renal failure ( 30.43% vs 5.40%; p=0.0016) are significant differences in SAS positive and SAS negative group. According to the 46 months duration follow-up, the survival rate of the two groups is with no significant differences ( p=0.0846). The SAS negative group result is survival time has no correlation significant with all the factors we explored. The SAS positive result is survival time has only correlation significant with pulmonary infection/failure ( r=0.2798, 95%CI 0.08741 to 0.452, p=0.0038). Stanford B AD patients combined with SAS are likely to have higher BMI. After treated by TEVAR, they usually have longer hospitalization and ICU stay time, as well as higher complications rate. However, there are no significant differences of the survival rate in mid-time follow-up. The respiratory system evaluation should be considerate carefully in those patients who has diagnosed as SAS before and after TEVAR because those patients' survival situation may has correlation with their respiratory condition. Copyright © 2018 Elsevier Inc. All rights reserved.
Effective augmentation of networked systems and enhancing pinning controllability
NASA Astrophysics Data System (ADS)
Jalili, Mahdi
2018-06-01
Controlling dynamics of networked systems to a reference state, known as pinning control, has many applications in science and engineering. In this paper, we introduce a method for effective augmentation of networked systems, while also providing high levels of pinning controllability for the final augmented network. The problem is how to connect a sub-network to an already existing network such that the pinning controllability is maximised. We consider the eigenratio of the augmented Laplacian matrix as a pinning controllability metric, and use graph perturbation theory to approximate the influence of edge addition on the eigenratio. The proposed metric can be effectively used to find the inter-network links connecting the disjoint networks. Also, an efficient link rewiring approach is proposed to further optimise the pinning controllability of the augmented network. We provide numerical simulations on synthetic networks and show that the proposed method is more effective than heuristic ones.
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the... the pilot were not aware of the failure. Warning systems must not activate the control systems. (b...
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the... the pilot were not aware of the failure. Warning systems must not activate the control systems. (b...
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the... the pilot were not aware of the failure. Warning systems must not activate the control systems. (b...
14 CFR 25.672 - Stability augmentation and automatic and power-operated systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.672 Stability augmentation and automatic and power-operated systems. If the... the pilot were not aware of the failure. Warning systems must not activate the control systems. (b...
A novel augmented reality system of image projection for image-guided neurosurgery.
Mahvash, Mehran; Besharati Tabrizi, Leila
2013-05-01
Augmented reality systems combine virtual images with a real environment. To design and develop an augmented reality system for image-guided surgery of brain tumors using image projection. A virtual image was created in two ways: (1) MRI-based 3D model of the head matched with the segmented lesion of a patient using MRIcro software (version 1.4, freeware, Chris Rorden) and (2) Digital photograph based model in which the tumor region was drawn using image-editing software. The real environment was simulated with a head phantom. For direct projection of the virtual image to the head phantom, a commercially available video projector (PicoPix 1020, Philips) was used. The position and size of the virtual image was adjusted manually for registration, which was performed using anatomical landmarks and fiducial markers position. An augmented reality system for image-guided neurosurgery using direct image projection has been designed successfully and implemented in first evaluation with promising results. The virtual image could be projected to the head phantom and was registered manually. Accurate registration (mean projection error: 0.3 mm) was performed using anatomical landmarks and fiducial markers position. The direct projection of a virtual image to the patients head, skull, or brain surface in real time is an augmented reality system that can be used for image-guided neurosurgery. In this paper, the first evaluation of the system is presented. The encouraging first visualization results indicate that the presented augmented reality system might be an important enhancement of image-guided neurosurgery.
A Multimedia, Augmented Reality Interactive System for the Application of a Guided School Tour
NASA Astrophysics Data System (ADS)
Lin, Ko-Chun; Huang, Sheng-Wen; Chu, Sheng-Kai; Su, Ming-Wei; Chen, Chia-Yen; Chen, Chi-Fa
The paper describes an implementation of a multimedia, augmented reality system used for a guided school tour. The aim of this work is to improve the level of interactions between a viewer and the system by means of augmented reality. In the implemented system, hand motions are captured via computer vision based approaches and analyzed to extract representative actions which are used to interact with the system. In this manner, tactile peripheral hardware such as keyboard and mouse can be eliminated. In addition, the proposed system also aims to reduce hardware related costs and avoid health risks associated with contaminations by contact in public areas.
14 CFR 29.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Control Systems § 29.672 Stability augmentation, automatic, and power-operated systems. If the... unsafe condition if the pilot is unaware of the failure. Warning systems must not activate the control...
14 CFR 27.672 - Stability augmentation, automatic, and power-operated systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Design and Construction Control Systems § 27.672 Stability augmentation, automatic, and power-operated systems. If the... unsafe condition if the pilot is unaware of the failure. Warning systems must not activate the control...
Critical review of the safety assessment of nano-structured silica additives in food.
Winkler, Hans Christian; Suter, Mark; Naegeli, Hanspeter
2016-06-10
The development of nano-materials is viewed as one of the most important technological advances of the 21st century and new applications of nano-sized particles in the production, processing, packaging or storage of food are expected to emerge soon. This trend of growing commercialization of engineered nano-particles as part of modern diet will substantially increase oral exposure. Contrary to the proven benefits of nano-materials, however, possible adverse health effects have generally received less attention. This problem is very well illustrated by nano-structured synthetic amorphous silica (SAS), which is a common food additive since several decades although the relevant risk assessment has never been satisfactorily completed. A no observed adverse effect level of 2500 mg SAS particles/kg body weight per day was derived from the only available long-term administration study in rodents. However, extrapolation to a safe daily intake for humans is problematic due to limitations of this chronic animal study and knowledge gaps as to possible local intestinal effects of SAS particles, primarily on the gut-associated lymphoid system. This uncertainty is aggravated by digestion experiments indicating that dietary SAS particles preserve their nano-sized structure when reaching the intestinal lumen. An important aspect is whether food-borne particles like SAS alter the function of dendritic cells that, embedded in the intestinal mucosa, act as first-line sentinels of foreign materials. We conclude that nano-particles do not represent a completely new threat and that most potential risks can be assessed following procedures established for conventional chemical hazards. However, specific properties of food-borne nano-particles should be further examined and, for that purpose, in vitro tests with decision-making cells of the immune system are needed to complement existing in vivo studies.
Usability engineering: domain analysis activities for augmented-reality systems
NASA Astrophysics Data System (ADS)
Gabbard, Joseph; Swan, J. E., II; Hix, Deborah; Lanzagorta, Marco O.; Livingston, Mark; Brown, Dennis B.; Julier, Simon J.
2002-05-01
This paper discusses our usability engineering process for the Battlefield Augmented Reality System (BARS). Usability engineering is a structured, iterative, stepwise development process. Like the related disciplines of software and systems engineering, usability engineering is a combination of management principals and techniques, formal and semi- formal evaluation techniques, and computerized tools. BARS is an outdoor augmented reality system that displays heads- up battlefield intelligence information to a dismounted warrior. The paper discusses our general usability engineering process. We originally developed the process in the context of virtual reality applications, but in this work we are adapting the procedures to an augmented reality system. The focus of this paper is our work on domain analysis, the first activity of the usability engineering process. We describe our plans for and our progress to date on our domain analysis for BARS. We give results in terms of a specific urban battlefield use case we have designed.
Human-in-the-loop evaluation of RMS Active Damping Augmentation
NASA Technical Reports Server (NTRS)
Demeo, Martha E.; Gilbert, Michael G.; Scott, Michael A.; Lepanto, Janet A.; Bains, Elizabeth M.; Jensen, Mary C.
1993-01-01
Active Damping Augmentation is the insertion of Controls-Structures Integration Technology to benefit the on-orbit performance of the Space Shuttle Remote Manipulator System. The goal is to reduce the vibration decay time of the Remote Manipulator System following normal payload maneuvers and operations. Simulation of Active Damping Augmentation was conducted in the realtime human-in-the-loop Systems Engineering Simulator at the NASA Johnson Space Center. The objective of this study was to obtain a qualitative measure of operational performance improvement from astronaut operators and to obtain supporting quantitative performance data. Sensing of vibratory motions was simulated using a three-axis accelerometer mounted at the end of the lower boom of the Remote Manipulator System. The sensed motions were used in a feedback control law to generate commands to the joint servo mechanisms which reduced the unwanted oscillations. Active damping of the Remote Manipulator System with an attached 3990 lb. payload was successfully demonstrated. Six astronaut operators examined the performance of an Active Damping Augmentation control law following single-joint and coordinated six-joint translational and rotational maneuvers. Active Damping Augmentation disturbance rejection of Orbiter thruster firings was also evaluated. Significant reductions in the dynamic response of the 3990 lb. payload were observed. Astronaut operators recommended investigation of Active Damping Augmentation benefits to heavier payloads where oscillations are a bigger problem (e.g. Space Station Freedom assembly operators).
Fiia: A Model-Based Approach to Engineering Collaborative Augmented Reality
NASA Astrophysics Data System (ADS)
Wolfe, Christopher; Smith, J. David; Phillips, W. Greg; Graham, T. C. Nicholas
Augmented reality systems often involve collaboration among groups of people. While there are numerous toolkits that aid the development of such augmented reality groupware systems (e.g., ARToolkit and Groupkit), there remains an enormous gap between the specification of an AR groupware application and its implementation. In this chapter, we present Fiia, a toolkit which simplifies the development of collaborative AR applications. Developers specify the structure of their applications using the Fiia modeling language, which abstracts details of networking and provides high-level support for specifying adapters between the physical and virtual world. The Fiia.Net runtime system then maps this conceptual model to a runtime implementation. We illustrate Fiia via Raptor, an augmented reality application used to help small groups collaboratively prototype video games.
Benefit assessment of solar-augmented natural gas systems
NASA Technical Reports Server (NTRS)
Davis, E. S.; French, R. L.; Sohn, R. L.
1980-01-01
Report details how solar-energy-augmented system can reduce natural gas consumption by 40% to 70%. Applications discussed include: domestic hot water system, solar-assisted gas heat pumps, direct heating from storage tank. Industrial uses, solar-assisted appliances, and economic factors are discussed.
Orion MPCV Continuum RCS Heating Augmentation Model Development
NASA Technical Reports Server (NTRS)
Hyatt, Andrew J.; White, Molly E.
2014-01-01
The reaction control system jets of the Orion Multi Purpose Crew Vehicle can have a significant impact on the magnitude and distribution of the surface heat flux on the leeside of the aft-body, when they are fired. Changes in surface heating are expressed in terms of augmentation factor over the baseline smooth body heating. Wind tunnel tests revealed heating augmentation factors as high as 13.0, 7.6, 2.8, and 5.8 for the roll, pitch down, pitch up, and yaw jets respectively. Heating augmentation factor models, based almost exclusively on data from a series of wind tunnel tests have been developed, for the purposes of thermal protection system design. The wind tunnel tests investigated several potential jet-to-freestream similarity parameters, and heating augmentation factors derived from the data showed correlation with the jet-to-freestream momentum ratio. However, this correlation was not utilized in the developed models. Instead augmentation factors were held constant throughout the potential trajectory space. This simplification was driven by the fact that ground to flight traceability and sting effects are not well understood. Given the sensitivity of the reaction control system jet heating augmentation to configuration, geometry, and orientation the focus in the present paper is on the methodology used to develop the models and the lessons learned from the data. The models that are outlined in the present work are specific to the aerothermal database used to design the thermal protection system for the Exploration Flight Test 1 vehicle.
NASA Technical Reports Server (NTRS)
Goeke, R. F.
1975-01-01
Spacecraft electronic systems usually demand tight packaging. It was this consideration which initially forced us to consider hybrid circuits for the analog signal processing circuits in the Small Astronomy Satellite-C (SAS-C) scientific payload. We gradually discovered that increased reliability, low power consumption, and reduced program costs all followed. This paper will attempt to share our laboratory's first experience with hybrid circuits and indicate those areas which we found to be important.
Bschor, Tom; Baethge, Christopher; Adli, Mazda; Lewitzka, Ute; Eichmann, Uta; Bauer, Michael
2003-01-01
Objective Lithium augmentation is an established strategy in the treatment of refractory depression, but little is known about predictors of response and its mode of action. There is increasing evidence that low thyroid function indices within the normal range are associated with a poorer treatment response to antidepressants, but previous studies on the hypothalamic-pituitary-thyroid (HPT) system during lithium augmentation provide inconclusive results and have methodological limitations. This study aimed at exploring the role of thyroid function in lithium augmentation and used a prospective design that included a homogeneous sample of inpatients with unipolar major depressive disorder. Methods In 24 euthyroid patients with a major depressive episode who had not responded to antidepressant monotherapy of at least 4 weeks, we measured serum thyroid-stimulating hormone (TSH), total triiodothyronine (T3) and total thyroxine (T4) before (baseline) and during lithium augmentation therapy (follow-up). The time point of the endocrinological follow-up depended on the status of response, which was assessed weekly with the Hamilton Depression Rating Scale, 17-item version (HDRS17). Responders were reassessed immediately after response was determined, and non-responders after 4 weeks of lithium augmentation. Results There was a statistically significant change in thyroid system activity during lithium augmentation, with an increase of TSH levels and a decrease of peripheral T3 and T4 levels. However, there were no differences in any of the HPT hormones between responders and non-responders at baseline or at follow-up. Conclusions The decrease of thyroid system activity during lithium treatment reflects the well-established “antithyroid” properties of lithium. However, it appears that thyroid status does not predict response to lithium augmentation in euthyroid patients before treatment. PMID:12790161
Surgical apgar score in patients undergoing lumbar fusion for degenerative spine diseases.
Ou, Chien-Yu; Hsu, Shih-Yuan; Huang, Jian-Hao; Huang, Yu-Hua
2017-01-01
Lumbar fusion is a procedure broadly performed for degenerative diseases of spines, but it is not without significant morbidities. Surgical Apgar Score (SAS), based on intraoperative blood loss, blood pressure, and heart rate, was developed for prognostic prediction in general and vascular operations. We aimed to examine whether the application of SAS in patients undergoing fusion procedures for degeneration of lumbar spines predicts in-hospital major complications. One hundred and ninety-nine patients that underwent lumbar fusion operation for spine degeneration were enrolled in this retrospective study. Based on whether major complications were present (N=16) or not (N=183), the patients were subdivided. We identified the intergroup differences in SAS and clinical parameters. The incidence of in-hospital major complications was 8%. The duration of hospital stay for the morbid patents was significantly prolonged (p=0.04). In the analysis of multivariable logistic regression, SAS was an independent predicting factor of the complications after lumbar fusion for degenerative spine diseases [p=0.001; odds ratio (95% confidence interval)=0.35 (0.19-0.64)]. Lower scores were accompanied with higher rates of major complications, and the area was 0.872 under the receiver operating characteristic curve. SAS is an independent predicting factor of major complications in patients after fusion surgery for degenerative diseases of lumbar spines, and provides good risk discrimination. Since the scoring system is relatively simple, objective, and practical, we suggest that SAS be included as an indicator in the guidance for level of care after lumbar fusion surgery. Copyright © 2016 Elsevier B.V. All rights reserved.
Design and implementation of reliability evaluation of SAS hard disk based on RAID card
NASA Astrophysics Data System (ADS)
Ren, Shaohua; Han, Sen
2015-10-01
Because of the huge advantage of RAID technology in storage, it has been widely used. However, the question associated with this technology is that the hard disk based on the RAID card can not be queried by Operating System. Therefore how to read the self-information and log data of hard disk has been a problem, while this data is necessary for reliability test of hard disk. In traditional way, this information can be read just suitable for SATA hard disk, but not for SAS hard disk. In this paper, we provide a method by using LSI RAID card's Application Program Interface, communicating with RAID card and analyzing the feedback data to solve the problem. Then we will get the necessary information to assess the SAS hard disk.
On the use of Augmented Reality techniques in learning and interpretation of cardiologic data.
Lamounier, Edgard; Bucioli, Arthur; Cardoso, Alexandre; Andrade, Adriano; Soares, Alcimar
2010-01-01
Augmented Reality is a technology which provides people with more intuitive ways of interaction and visualization, close to those in real world. The amount of applications using Augmented Reality is growing every day, and results can be already seen in several fields such as Education, Training, Entertainment and Medicine. The system proposed in this article intends to provide a friendly and intuitive interface based on Augmented Reality for heart beating evaluation and visualization. Cardiologic data is loaded from several distinct sources: simple standards of heart beating frequencies (for example situations like running or sleeping), files of heart beating signals, scanned electrocardiographs and real time data acquisition of patient's heart beating. All this data is processed to produce visualization within Augmented Reality environments. The results obtained in this research have shown that the developed system is able to simplify the understanding of concepts about heart beating and its functioning. Furthermore, the system can help health professionals in the task of retrieving, processing and converting data from all the sources handled by the system, with the support of an edition and visualization mode.
An augmented reality system for upper-limb post-stroke motor rehabilitation: a feasibility study.
Assis, Gilda Aparecida de; Corrêa, Ana Grasielle Dionísio; Martins, Maria Bernardete Rodrigues; Pedrozo, Wendel Goes; Lopes, Roseli de Deus
2016-08-01
To determine the clinical feasibility of a system based on augmented reality for upper-limb (UL) motor rehabilitation of stroke participants. A physiotherapist instructed the participants to accomplish tasks in augmented reality environment, where they could see themselves and their surroundings, as in a mirror. Two case studies were conducted. Participants were evaluated pre- and post-intervention. The first study evaluated the UL motor function using Fugl-Meyer scale. Data were compared using non-parametric sign tests and effect size. The second study used the gain of motion range of shoulder flexion and abduction assessed by computerized biophotogrammetry. At a significance level of 5%, Fugl-Meyer scores suggested a trend for greater UL motor improvement in the augmented reality group than in the other. Moreover, effect size value 0.86 suggested high practical significance for UL motor rehabilitation using the augmented reality system. System provided promising results for UL motor rehabilitation, since enhancements have been observed in the shoulder range of motion and speed. Implications for Rehabilitation Gain of range of motion of flexion and abduction of the shoulder of post-stroke patients can be achieved through an augmented reality system containing exercises to promote the mental practice. NeuroR system provides a mental practice method combined with visual feedback for motor rehabilitation of chronic stroke patients, giving the illusion of injured upper-limb (UL) movements while the affected UL is resting. Its application is feasible and safe. This system can be used to improve UL rehabilitation, an additional treatment past the traditional period of the stroke patient hospitalization and rehabilitation.
NASA Technical Reports Server (NTRS)
Homick, J. L.; Reschke, M. F.; Vanderploeg, J. M.
1984-01-01
Better methods for the prediction, prevention, and treatment of the space adaptation syndome (SAS) were developed. A systematic, long range program of operationally oriented data collection on all individuals flying space shuttle missions was initiated. Preflight activities include the use of a motion experience questionnaire, laboratory tests of susceptibility to motion sickness induced by Coriolis stimuli and determinations of antimotion sickness drug efficacy and side effects. During flight, each crewmember is required to provide a daily report of symptom status, use of medications, and other vestibular related sensations. Additional data are obtained postflight. During the first nine shuttle missions, the reported incidence of SAS has been48%. Self-induced head motions and unusual visual orientation attitudes appear to be the principal triggering stimuli. Antimotion sickness medication, was of limited therapeutic value. Complete recovery from symptoms occurred by mission day three or four. Also of relevance is the lack of a statistically significant correlation between the ground based Coriolis test and SAS. The episodes of SAS have resulted in no impact to shuttle mission objectives and, no significant impact to mission timelines.
NASA Technical Reports Server (NTRS)
Chernyakov, Boris; Thakore, Kamal
2010-01-01
Launched June 18, 2009 on an Atlas V rocket, NASA's Lunar Reconnaissance Orbiter (LRO) is the first step in NASA's Vision for Space Exploration program and for a human return to the Moon. The spacecraft (SC) carries a wide variety of scientific instruments and provides an extraordinary opportunity to study the lunar landscape at resolutions and over time scales never achieved before. The spacecraft systems are designed to enable achievement of LRO's mission requirements. To that end, LRO's mechanical system employed two two-axis gimbal assemblies used to drive the deployment and articulation of the Solar Array System (SAS) and the High Gain Antenna System (HGAS). This paper describes the design, development, integration, and testing of Gimbal Control Electronics (GCE) and Actuators for both the HGAS and SAS systems, as well as flight testing during the on-orbit commissioning phase and lessons learned.
Characteristic Risk Factors Associated with Planned versus Impulsive Suicide Attempters.
Kim, Jaeha; Lee, Kang-Sook; Kim, Dai Jin; Hong, Seung-Chul; Choi, Kyoung Ho; Oh, Youngmin; Wang, Sheng-Min; Lee, Hae-Kook; Kweon, Yong-Sil; Lee, Chung Tai; Lee, Kyoung-Uk
2015-12-31
The present study aimed to investigate predictors for planned suicide attempters. This study included 1,003 patients who attempted suicide and visited emergency department. They were divided into two groups, planned suicide attempters (SAs; n=133 [13.3%]) and impulsive SAs (n=870, [86.7%]), and the demographic variables, clinical characteristics, factors related to suicide, and psychiatric resources of the groups were compared. Major depressive disorder and substance use disorders were more common among planned SAs than among impulsive SAs. Additionally, the planned SAs were older, more likely to be divorced, separated or widowed, and more likely to have comorbid medical illnesses, severe depression, higher suicidality, and self-blaming tendencies than the impulsive SAs. Financial problems and physical illnesses were more common in planned SAs but interpersonal conflicts were more frequent in impulsive SAs. Planned SAs had fewer previous suicide attempts but these were more serious suicide attempts. The presence of the hope to die, a written will, and suicidal ideation of a repetitive, intense, and continuous nature were predictive of planned SAs. The present findings demonstrated that planned SAs had more severe psychopathology and medical illnesses than impulsive SAs. Therefore, screening for depression, substance use disorders, and suicidal plans among old and medically ill patients may be important for preventing suicide attempts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Sandia National Laboratories has developed a state-of-the-art augmented reality training system for close-quarters combat (CQB). This system uses a wearable augmented reality system to place the user in a real environment while engaging enemy combatants in virtual space (Boston Dynamics DI-Guy). Umbra modeling and simulation environment is used to integrate and control the AR system.
Towards Pervasive Augmented Reality: Context-Awareness in Augmented Reality.
Grubert, Jens; Langlotz, Tobias; Zollmann, Stefanie; Regenbrecht, Holger
2017-06-01
Augmented Reality is a technique that enables users to interact with their physical environment through the overlay of digital information. While being researched for decades, more recently, Augmented Reality moved out of the research labs and into the field. While most of the applications are used sporadically and for one particular task only, current and future scenarios will provide a continuous and multi-purpose user experience. Therefore, in this paper, we present the concept of Pervasive Augmented Reality, aiming to provide such an experience by sensing the user's current context and adapting the AR system based on the changing requirements and constraints. We present a taxonomy for Pervasive Augmented Reality and context-aware Augmented Reality, which classifies context sources and context targets relevant for implementing such a context-aware, continuous Augmented Reality experience. We further summarize existing approaches that contribute towards Pervasive Augmented Reality. Based our taxonomy and survey, we identify challenges for future research directions in Pervasive Augmented Reality.
Shen, Xin; Javidi, Bahram
2018-03-01
We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.
Extension of the sasCIF format and its applications for data processing and deposition
Kachala, Michael; Westbrook, John; Svergun, Dmitri
2016-02-01
Recent advances in small-angle scattering (SAS) experimental facilities and data analysis methods have prompted a dramatic increase in the number of users and of projects conducted, causing an upsurge in the number of objects studied, experimental data available and structural models generated. To organize the data and models and make them accessible to the community, the Task Forces on SAS and hybrid methods for the International Union of Crystallography and the Worldwide Protein Data Bank envisage developing a federated approach to SAS data and model archiving. Within the framework of this approach, the existing databases may exchange information and providemore » independent but synchronized entries to users. At present, ways of exchanging information between the various SAS databases are not established, leading to possible duplication and incompatibility of entries, and limiting the opportunities for data-driven research for SAS users. In this work, a solution is developed to resolve these issues and provide a universal exchange format for the community, based on the use of the widely adopted crystallographic information framework (CIF). The previous version of the sasCIF format, implemented as an extension of the core CIF dictionary, has been available since 2000 to facilitate SAS data exchange between laboratories. The sasCIF format has now been extended to describe comprehensively the necessary experimental information, results and models, including relevant metadata for SAS data analysis and for deposition into a database. Processing tools for these files (sasCIFtools) have been developed, and these are available both as standalone open-source programs and integrated into the SAS Biological Data Bank, allowing the export and import of data entries as sasCIF files. Software modules to save the relevant information directly from beamline data-processing pipelines in sasCIF format are also developed. Lastly, this update of sasCIF and the relevant tools are an important step in the standardization of the way SAS data are presented and exchanged, to make the results easily accessible to users and to promote further the application of SAS in the structural biology community.« less
Advanced intellect-augmentation techniques
NASA Technical Reports Server (NTRS)
Engelbart, D. C.
1972-01-01
User experience in applying our augmentation tools and techniques to various normal working tasks within our center is described so as to convey a subjective impression of what it is like to work in an augmented environment. It is concluded that working-support, computer-aid systems for augmenting individuals and teams, are undoubtedly going to be widely developed and used. A very special role in this development is seen for multi-access computer networks.
Augmented Reality: A Brand New Challenge for the Assessment and Treatment of Psychological Disorders
Chicchi Giglioli, Irene Alice; Pedroli, Elisa
2015-01-01
Augmented Reality is a new technological system that allows introducing virtual contents in the real world in order to run in the same representation and, in real time, enhancing the user's sensory perception of reality. From another point of view, Augmented Reality can be defined as a set of techniques and tools that add information to the physical reality. To date, Augmented Reality has been used in many fields, such as medicine, entertainment, maintenance, architecture, education, and cognitive and motor rehabilitation but very few studies and applications of AR exist in clinical psychology. In the treatment of psychological disorders, Augmented Reality has given preliminary evidence to be a useful tool due to its adaptability to the patient needs and therapeutic purposes and interactivity. Another relevant factor is the quality of the user's experience in the Augmented Reality system determined from emotional engagement and sense of presence. This experience could increase the AR ecological validity in the treatment of psychological disorders. This paper reviews the recent studies on the use of Augmented Reality in the evaluation and treatment of psychological disorders, focusing on current uses of this technology and on the specific features that delineate Augmented Reality a new technique useful for psychology. PMID:26339283
Chicchi Giglioli, Irene Alice; Pallavicini, Federica; Pedroli, Elisa; Serino, Silvia; Riva, Giuseppe
2015-01-01
Augmented Reality is a new technological system that allows introducing virtual contents in the real world in order to run in the same representation and, in real time, enhancing the user's sensory perception of reality. From another point of view, Augmented Reality can be defined as a set of techniques and tools that add information to the physical reality. To date, Augmented Reality has been used in many fields, such as medicine, entertainment, maintenance, architecture, education, and cognitive and motor rehabilitation but very few studies and applications of AR exist in clinical psychology. In the treatment of psychological disorders, Augmented Reality has given preliminary evidence to be a useful tool due to its adaptability to the patient needs and therapeutic purposes and interactivity. Another relevant factor is the quality of the user's experience in the Augmented Reality system determined from emotional engagement and sense of presence. This experience could increase the AR ecological validity in the treatment of psychological disorders. This paper reviews the recent studies on the use of Augmented Reality in the evaluation and treatment of psychological disorders, focusing on current uses of this technology and on the specific features that delineate Augmented Reality a new technique useful for psychology.
Computer Augmented Learning; A Survey.
ERIC Educational Resources Information Center
Kindred, J.
The report contains a description and summary of computer augmented learning devices and systems. The devices are of two general types programed instruction systems based on the teaching machines pioneered by Pressey and developed by Skinner, and the so-called "docile" systems that permit greater user-direction with the computer under student…
3D interactive augmented reality-enhanced digital learning systems for mobile devices
NASA Astrophysics Data System (ADS)
Feng, Kai-Ten; Tseng, Po-Hsuan; Chiu, Pei-Shuan; Yang, Jia-Lin; Chiu, Chun-Jie
2013-03-01
With enhanced processing capability of mobile platforms, augmented reality (AR) has been considered a promising technology for achieving enhanced user experiences (UX). Augmented reality is to impose virtual information, e.g., videos and images, onto a live-view digital display. UX on real-world environment via the display can be e ectively enhanced with the adoption of interactive AR technology. Enhancement on UX can be bene cial for digital learning systems. There are existing research works based on AR targeting for the design of e-learning systems. However, none of these work focuses on providing three-dimensional (3-D) object modeling for en- hanced UX based on interactive AR techniques. In this paper, the 3-D interactive augmented reality-enhanced learning (IARL) systems will be proposed to provide enhanced UX for digital learning. The proposed IARL systems consist of two major components, including the markerless pattern recognition (MPR) for 3-D models and velocity-based object tracking (VOT) algorithms. Realistic implementation of proposed IARL system is conducted on Android-based mobile platforms. UX on digital learning can be greatly improved with the adoption of proposed IARL systems.
Embedding Augmentative Communication within Early Childhood Classrooms.
ERIC Educational Resources Information Center
DiCarlo, Cynthia; Banajee, Meher; Stricklin, Sarintha Buras
2000-01-01
This article first describes various augmentative communication systems including sign language, picture symbols, and voice output communication devices. It then explains ways to embed augmentative communication within four types of early childhood classroom activities: (1) special or planned activities, (2) meal time, (3) circle time, and (4)…
FY2017 Updates to the SAS4A/SASSYS-1 Safety Analysis Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanning, T. H.
The SAS4A/SASSYS-1 safety analysis software is used to perform deterministic analysis of anticipated events as well as design-basis and beyond-design-basis accidents for advanced fast reactors. It plays a central role in the analysis of U.S. DOE conceptual designs, proposed test and demonstration reactors, and in domestic and international collaborations. This report summarizes the code development activities that have taken place during FY2017. Extensions to the void and cladding reactivity feedback models have been implemented, and Control System capabilities have been improved through a new virtual data acquisition system for plant state variables and an additional Block Signal for a variablemore » lag compensator to represent reactivity feedback for novel shutdown devices. Current code development and maintenance needs are also summarized in three key areas: software quality assurance, modeling improvements, and maintenance of related tools. With ongoing support, SAS4A/SASSYS-1 can continue to fulfill its growing role in fast reactor safety analysis and help solidify DOE’s leadership role in fast reactor safety both domestically and in international collaborations.« less
Sir- and silencer-independent disruption of silencing in Saccharomyces by Sas10p.
Kamakaka, R T; Rine, J
1998-06-01
A promoter fusion library of Saccharomyces cerevisiae genes was used to exploit phenotypes associated with altered protein dosage. We identified a novel gene, SAS10, by the ability of Sas10p, when overproduced, to disrupt silencing. The predicted Sas10p was 70,200 kD and strikingly rich in charged amino acids. Sas10p was exclusively nuclear in all stages of the cell cycle. Overproduction of Sas10p caused derepression of mating type genes at both HML and HMR, as well as of URA3, TRP1, and ADE2 when inserted near a telomere or at HMR or the rDNA locus. Repressed genes not associated with silenced chromatin were unaffected. Sas10p was essential for viability, and the termination point following Sas10p depletion was as large budded cells. Remarkably, Sas10p overproduction disrupted silencing even under conditions that bypassed the requirement for Sir proteins, ORC, and Rap1p in silencing. These data implied that Sas10p function was intimately connected with the structure of silenced chromatin.
An augmented reality haptic training simulator for spinal needle procedures.
Sutherland, Colin; Hashtrudi-Zaad, Keyvan; Sellens, Rick; Abolmaesumi, Purang; Mousavi, Parvin
2013-11-01
This paper presents the prototype for an augmented reality haptic simulation system with potential for spinal needle insertion training. The proposed system is composed of a torso mannequin, a MicronTracker2 optical tracking system, a PHANToM haptic device, and a graphical user interface to provide visual feedback. The system allows users to perform simulated needle insertions on a physical mannequin overlaid with an augmented reality cutaway of patient anatomy. A tissue model based on a finite-element model provides force during the insertion. The system allows for training without the need for the presence of a trained clinician or access to live patients or cadavers. A pilot user study demonstrates the potential and functionality of the system.
Flexible augmented reality architecture applied to environmental management
NASA Astrophysics Data System (ADS)
Correia, Nuno M. R.; Romao, Teresa; Santos, Carlos; Trabuco, Adelaide; Santos, Rossana; Romero, Luis; Danado, Jose; Dias, Eduardo; Camara, Antonio; Nobre, Edmundo
2003-05-01
Environmental management often requires in loco observation of the area under analysis. Augmented Reality (AR) technologies allow real time superimposition of synthetic objects on real images, providing augmented knowledge about the surrounding world. Users of an AR system can visualize the real surrounding world together with additional data generated in real time in a contextual way. The work reported in this paper was done in the scope of ANTS (Augmented Environments) project. ANTS is an AR project that explores the development of an augmented reality technological infrastructure for environmental management. This paper presents the architecture and the most relevant modules of ANTS. The system"s architecture follows the client-server model and is based on several independent, but functionally interdependent modules. It has a flexible design, which allows the transfer of some modules to and from the client side, according to the available processing capacities of the client device and the application"s requirements. It combines several techniques to identify the user"s position and orientation allowing the system to adapt to the particular characteristics of each environment. The determination of the data associated to a certain location involves the use of both a 3D Model of the location and the multimedia geo-referenced database.
GPS/GLONASS RAIM augmentation to WAAS for CAT 1 precision approach
DOT National Transportation Integrated Search
1997-06-30
This paper deals with the potential use of Receiver Autonomous Integrity Monitoring @AIM) to supplement the FAAs Wide Area Augmentation System (WAAS). Integrity refers to the capability of a navigation or landing system to provide a timely warning...
NASA Astrophysics Data System (ADS)
Wardani, D. S.; Kirana, T.; Ibrahim, M.
2018-01-01
The aim of this research is to produce SAS based on MI and problem-solving skills using simple science tools that are suitable to be used by elementary school students. The feasibility of SAS is evaluated based on its validity, practicality, and effectiveness. The completion Lesson Plan (LP) implementation and student’s activities are the indicators of SAS practicality. The effectiveness of SAS is measured by indicators of increased learning outcomes and problem-solving skills. The development of SAS follows the 4-D (define, design, develop, and disseminate) phase. However, this study was done until the third stage (develop). The written SAS was then validated through expert evaluation done by two experts of science, before its is tested to the target students. The try-out of SAS used one group with pre-test and post-test design. The result of this research shows that SAS is valid with “good” category. In addition, SAS is considered practical as seen from the increase of student activity at each meeting and LP implementation. Moreover, it was considered effective due to the significant difference between pre-test and post-test result of the learning outcomes and problem-solving skill test. Therefore, SAS is feasible to be used in learning.
Personalized augmented reality for anatomy education.
Ma, Meng; Fallavollita, Pascal; Seelbach, Ina; Von Der Heide, Anna Maria; Euler, Ekkehard; Waschke, Jens; Navab, Nassir
2016-05-01
Anatomy education is a challenging but vital element in forming future medical professionals. In this work, a personalized and interactive augmented reality system is developed to facilitate education. This system behaves as a "magic mirror" which allows personalized in-situ visualization of anatomy on the user's body. Real-time volume visualization of a CT dataset creates the illusion that the user can look inside their body. The system comprises a RGB-D sensor as a real-time tracking device to detect the user moving in front of a display. In addition, the magic mirror system shows text information, medical images, and 3D models of organs that the user can interact with. Through the participation of 7 clinicians and 72 students, two user studies were designed to respectively assess the precision and acceptability of the magic mirror system for education. The results of the first study demonstrated that the average precision of the augmented reality overlay on the user body was 0.96 cm, while the results of the second study indicate 86.1% approval for the educational value of the magic mirror, and 91.7% approval for the augmented reality capability of displaying organs in three dimensions. The usefulness of this unique type of personalized augmented reality technology has been demonstrated in this paper. © 2015 Wiley Periodicals, Inc.
Preliminary design-lift/cruise fan research and technology airplane flight control system
NASA Technical Reports Server (NTRS)
Gotlieb, P.; Lewis, G. E.; Little, L. J.
1976-01-01
This report presents the preliminary design of a stability augmentation system for a NASA V/STOL research and technology airplane. This stability augmentation system is postulated as the simplest system that meets handling qualities levels for research and technology missions flown by NASA test pilots. The airplane studied in this report is a T-39 fitted with tilting lift/cruise fan nacelles and a nose fan. The propulsion system features a shaft interconnecting the three variable pitch fans and three power plants. The mathematical modeling is based on pre-wind tunnel test estimated data. The selected stability augmentation system uses variable gains scheduled with airspeed. Failure analysis of the system illustrates the benign effect of engine failure. Airplane rate sensor failure must be solved with redundancy.
The preliminary design of a lift-cruise fan airplane flight control system
NASA Technical Reports Server (NTRS)
Gotlieb, P.
1977-01-01
This paper presents the preliminary design of a stability augmentation system for a NASA V/STOL research and technology airplane. This stability augmentation system is postulated as the simplest system that meets handling-quality levels for research and technology missions flown by NASA test pilots. The airplane studied in this report is a modified T-39 fitted with tilting lift/cruise fan nacelles and a nose fan. The propulsion system features a shaft that interconnects three variable-pitch fans and three powerplants. The mathematical modeling is based on pre-wind tunnel test estimated data. The selected stability augmentation system uses variable gains scheduled with airspeed. Failure analysis of the system illustrates the benign effect of engine failure. Airplane rate sensor failure must be solved with redundancy.
Experiences with an Augmented Human Intellect System: A Revolution in Communication.
ERIC Educational Resources Information Center
Bair, James H.
The Augmented Human Intellect System (AHI) has been designed to facilitate communication among knowledge workers who may accomplish their entire job utilizing this advanced technology. The system is capable of sending information to geographically distributed users. It permits access to and modification of stored information by a number of persons…
ERIC Educational Resources Information Center
Lin, Hao-Chiang Koong; Chen, Mei-Chi; Chang, Chih-Kai
2015-01-01
This study integrates augmented reality (AR) technology into teaching activities to design a learning system that assists junior high-school students in learning solid geometry. The following issues are addressed: (1) the relationship between achievements in mathematics and performance in spatial perception; (2) whether system-assisted learning…
Li, Tianxiang; Shi, Zhengren; He, Xianru; Jiang, Ping; Lu, Xiaobin; Zhang, Rui; Wang, Xin
2018-05-18
With the aim of improving the anti-aging properties of nitrile-butadiene rubber (NBR), a functional organic filler, namely LDH⁻SAS, prepared by intercalating 4-amino-benzenesulfonic acid monosodium salt (SAS) into layered double hydroxides (LDHs) through anion exchange, was added to nitrile-butadiene rubber (NBR), giving the NBR/LDH⁻SAS composites. Successful preparation of LDH⁻SAS was confirmed by XRD, TGA and FTIR. LDH⁻SAS was well dispersed in the NBR matrix, owing to its strong interaction with the nitrile group of NBR. The obtained NBR/LDH⁻SAS composites exhibited excellent thermo-oxidative aging resistance as shown by TGA-DSC. Further investigation by ATR-FTIR indicated that SAS can capture the radical groups, even during the aging process, which largely accounts for the improved aging resistance.
Li, Tianxiang; Shi, Zhengren; He, Xianru; Jiang, Ping; Lu, Xiaobin; Zhang, Rui
2018-01-01
With the aim of improving the anti-aging properties of nitrile-butadiene rubber (NBR), a functional organic filler, namely LDH–SAS, prepared by intercalating 4-amino-benzenesulfonic acid monosodium salt (SAS) into layered double hydroxides (LDHs) through anion exchange, was added to nitrile-butadiene rubber (NBR), giving the NBR/LDH–SAS composites. Successful preparation of LDH–SAS was confirmed by XRD, TGA and FTIR. LDH–SAS was well dispersed in the NBR matrix, owing to its strong interaction with the nitrile group of NBR. The obtained NBR/LDH–SAS composites exhibited excellent thermo-oxidative aging resistance as shown by TGA-DSC. Further investigation by ATR-FTIR indicated that SAS can capture the radical groups, even during the aging process, which largely accounts for the improved aging resistance. PMID:29783656
Human grasp assist device and method of use
NASA Technical Reports Server (NTRS)
Linn, Douglas Martin (Inventor); Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor)
2012-01-01
A grasp assist device includes a glove portion having phalange rings, contact sensors for measuring a grasping force applied by an operator wearing the glove portion, and a tendon drive system (TDS). The device has flexible tendons connected to the phalange rings for moving the rings in response to feedback signals from the sensors. The TDS is connected to each of the tendons, and applies an augmenting tensile force thereto via a microcontroller adapted for determining the augmenting tensile force as a function of the grasping force. A method of augmenting a grasping force of an operator includes measuring the grasping force using the sensors, encoding the grasping force as the feedback signals, and calculating the augmenting tensile force as a function of the feedback signals using the microcontroller. The method includes energizing at least one actuator of a tendon drive system (TDS) to thereby apply the augmenting tensile force.
Kuwahara, Yoshikazu; Mori, Miyuki; Kitahara, Shuji; Fukumoto, Motoi; Ezaki, Taichi; Mori, Shiro; Echigo, Seishi; Ohkubo, Yasuhito; Fukumoto, Manabu
2014-01-01
Radiotherapy is widely used to treat cancer because it has the advantage of physically and functionally conserving the affected organ. To improve radiotherapy and investigate the molecular mechanisms of cellular radioresistance, we established a clinically relevant radioresistant (CRR) cell line, SAS-R, from SAS cells. SAS-R cells continue to proliferate when exposed to fractionated radiation (FR) of 2 Gy/day for more than 30 days in vitro. A xenograft tumor model of SAS-R was also resistant to 2 Gy/day of X-rays for 30 days. The density of blood vessels in SAS-R tumors was higher than in SAS tumors. Everolimus, a mammalian target of rapamycin (mTOR) inhibitor, sensitized microvascular endothelial cells to radiation, but failed to radiosensitize SAS and SAS-R cells in vitro. Everolimus with FR markedly reduced SAS and SAS-R tumor volumes. Additionally, the apoptosis of endothelial cells (ECs) increased in SAS-R tumor tissues when both Everolimus and radiation were administered. Both CD34-positive and tomato lectin-positive blood vessel densities in SAS-R tumor tissues decreased remarkably after the Everolimus and radiation treatment. Everolimus-induced apoptosis of vascular ECs in response to radiation was also followed by thrombus formation that leads to tumor necrosis. We conclude that FR combined with Everolimus may be an effective modality to overcome radioresistant tumors via targeting tumor ECs. PMID:24464839
Ulak, Güner; Mutlu, Oguz; Akar, Füruzan Yildiz; Komsuoğlu, F Ipek; Tanyeri, Pelin; Erden, B Faruk
2008-10-01
Treatment-resistant depression has necessitated new therapeutic strategies in augmenting the therapeutic actions of currently existing antidepressant drugs. The aim of this study was to investigate the possibility of synergistic interaction between 1-(2-trifluoromethylphenyl)-imidazole (TRIM), a novel neuronal nitric oxide synthase (nNOS) inhibitor and conventional antidepressants of different classes in the forced swimming test (FST) in rats. TRIM decreased the immobility time at 50 mg/kg doses in the FST in rats. Treatment with a behaviourally subeffective dose of TRIM (20 mg/kg) augmented the behavioural effect of tricyclic antidepressant imipramine, selective serotonin re-uptake inhibitor (SSRI) citalopram and fluoxetine or selective serotonin reuptake enhancer tianeptine but failed to augment the antidepressant effect of reboxetine, a noradrenaline re-uptake inhibitor, in this test. Therefore inhibition of NOS augments the effects of antidepressants acting on serotonergic system in the FST. Neither TRIM (10-50 mg/kg) nor other drug treatments affected the locomotor activity of animals. These findings are in agreement with the view that antidepressant effects or augmentation of these effects in the FST may be explained with inhibition of NOS activity and this may be a new approach in offering greater therapeutic efficacy of antidepressants acting via serotonergic system.
Augmented kinematic feedback from haptic virtual reality for dental skill acquisition.
Suebnukarn, Siriwan; Haddawy, Peter; Rhienmora, Phattanapon; Jittimanee, Pannapa; Viratket, Piyanuch
2010-12-01
We have developed a haptic virtual reality system for dental skill training. In this study we examined several kinds of kinematic information about the movement provided by the system supplement knowledge of results (KR) in dental skill acquisition. The kinematic variables examined involved force utilization (F) and mirror view (M). This created three experimental conditions that received augmented kinematic feedback (F, M, FM) and one control condition that did not (KR-only). Thirty-two dental students were randomly assigned to four groups. Their task was to perform access opening on the upper first molar with the haptic virtual reality system. An acquisition session consisted of two days of ten trials of practice in which augmented kinematic feedback was provided for the appropriate experimental conditions after each trial. One week after, a retention test consisting of two trials without augmented feedback was completed. The results showed that the augmented kinematic feedback groups had larger mean performance scores than the KR-only group in Day 1 of the acquisition and retention sessions (ANOVA, p<0.05). The apparent differences among feedback groups were not significant in Day 2 of the acquisition session (ANOVA, p>0.05). The trends in acquisition and retention sessions suggest that the augmented kinematic feedback can enhance the performance earlier in the skill acquisition and retention sessions.
Murray, Louis C.
2010-01-01
Multivariate linear regression analyses were used to define the relations of water levels in the Upper Floridan aquifer (UFA) and surficial aquifer system (SAS) to anthropogenic and meteorological stressors between 1995 and 2007 at two monitoring well sites (Charlotte Street and Lake Oliver) in east-central Florida. Anthropogenic stressors of interest included municipal and agricultural groundwater withdrawals, and application of reclaimed-water to rapid-infiltration basins (source of aquifer recharge). Meteorological stressors included precipitation and potential evapotranspiration. Overall, anthropogenic and meteorological stressors accounted for about 40 to 89 percent of the variance in UFA and SAS groundwater levels and water-level changes. While mean monthly water levels were better correlated with monthly stressor values, changes in UFA and SAS water levels were better correlated with changes in stressor values. Water levels and water-level changes were influenced by system persistence as the moving-averaged values of both stressor types, which accounted for the influence of the previous month(s) conditions, consistently yielded higher adjusted coefficients of determination (R2 adj) values than did single monthly values. While monthly water-level changes tend to be influenced equally with both stressors across the hydrologically averaged 13-year period, changes were more influenced by one stressor or the other seasonally and during extended wet and dry periods. Seasonally, UFA water-level changes tended to be more influenced by anthropogenic stressors than by meteorological stressors, while changes in SAS water levels tended to be more influenced by meteorological stressors. During extended dry periods (12 months or greater), changes in UFA water levels at Charlotte Street were more affected by anthropogenic stressors than by meteorological stressors, while changes in SAS levels were more affected by meteorological stressors. At Lake Oliver, changes in both UFA and SAS water levels were better correlated with meteorological stressors for all but the wet period between April 1995 and April 1996. Interestingly, changes in both UFA and SAS water levels at Charlotte Street were also better correlated with anthropogenic stressors during a similar wet period between April 1995 and June 1996 when substantive reductions in groundwater withdrawals resulted in appreciable recovery of both UFA and SAS water levels. The regional effects of anthropogenic stressors had limited influence on water-level changes at Charlotte Street and virtually no influence on changes at Lake Oliver. When regressed against the 2.2 Mgal/d (million gallons per day) of municipal withdrawals located within 2 miles of the Charlotte Street site, water-level changes were influenced solely by precipitation and potential evapotranspiration. At a radius of 2.5 miles, however, where cumulative withdrawals totaled about 9.5 Mgal/d, water-level changes were equally influenced by both anthropogenic and meteorological stressors. Withdrawals located at distances of greater than 3 miles from this site had no appreciable effect on relations between water-level changes and these stressors. At Lake Oliver, changes in UFA water levels were equally influenced by both stressors regardless of distance, while changes in SAS levels were more influenced by meteorological stressors at all distances.
Woodruff, M. F. A.; Inchley, M. P.
1971-01-01
The cytotoxic titre−1 of rabbit-anti-mouse thymocyte IgG (ALG), determined by a modified test in which the cells were first incubated with ALG, then washed and re-incubated with guinea-pig C, ranged from 3110 to 5470. The cytolytic efficiency (i.e. the reciprocal of the mean number of IgG molecules attached per cell under conditions in which 50% lysis occurs in the presence of C), measured with 131I-ALG, was about 0·002%. When γ2 IgG from guinea-pigs immunized with rabbit IgG was added prior to the second incubation the cytotoxic titre was augmented up to ten-fold and the cytotoxic efficiency up to twenty-fold. The same γ2 preparation resulted in up to 300-fold augmentation in a haemolytic system. In the thymocyte-ALG system, unlike the haemolytic system, augmentation was maximal at reduced concentrations of γ2. The mechanism of augmentation by γ2 has been investigated using 131I-ALG and 125I- γ2 IgG. PMID:5316638
Kim, Il-Hwan; Bong, Jae-Hwan; Park, Jooyoung; Park, Shinsuk
2017-01-01
Driver assistance systems have become a major safety feature of modern passenger vehicles. The advanced driver assistance system (ADAS) is one of the active safety systems to improve the vehicle control performance and, thus, the safety of the driver and the passengers. To use the ADAS for lane change control, rapid and correct detection of the driver’s intention is essential. This study proposes a novel preprocessing algorithm for the ADAS to improve the accuracy in classifying the driver’s intention for lane change by augmenting basic measurements from conventional on-board sensors. The information on the vehicle states and the road surface condition is augmented by using an artificial neural network (ANN) models, and the augmented information is fed to a support vector machine (SVM) to detect the driver’s intention with high accuracy. The feasibility of the developed algorithm was tested through driving simulator experiments. The results show that the classification accuracy for the driver’s intention can be improved by providing an SVM model with sufficient driving information augmented by using ANN models of vehicle dynamics. PMID:28604582
Cosmetic tourism for breast augmentation: a systematic review.
Brightman, Louise; Ng, Sze; Ahern, Susannah; Cooter, Rodney; Hopper, Ingrid
2017-12-03
The medical tourism industry, and in particular cosmetic tourism for breast augmentation, is becoming an increasingly popular global phenomenon. The objective of this study is to determine the extent of medical literature and the patient risk profiles associated with cosmetic tourism for breast augmentation both locally and abroad. OVID MEDLINE, OVID Embase, Cochrane Central and Proquest electronic databases. The search was conducted through to April 2017. Studies pertaining entirely or partly to cosmetic tourism for breast augmentation were considered for inclusion. Exclusion criteria included non-English articles, studies relating to non-cosmetic or non-implant breast augmentation, and studies that did not separately report on findings associated with breast augmentation abroad. We identified 17 observational studies. Common destinations included Europe, South America and South East Asia. Infectious complications were common. Wound dehiscence and aesthetic dissatisfaction also featured. Catastrophic outcomes such as sepsis, intubation and ventilation, radical bilateral mastectomy, irreversible hypoxic brain injury and death were also reported. There were expectations that home country health systems would treat complications and provide non-medically indicated revision procedures. The burden on home country health systems was evident from a public health perspective. Determining the extent of cosmetic tourism for breast augmentation, including outcomes and complications, will help to inform Australian patients who this seek procedure abroad. Furthermore, it will aid in better understanding the health system implications and may help to guide future research and public health interventions both locally and internationally. © 2017 Royal Australasian College of Surgeons.
Reduced-Order Kalman Filtering for Processing Relative Measurements
NASA Technical Reports Server (NTRS)
Bayard, David S.
2008-01-01
A study in Kalman-filter theory has led to a method of processing relative measurements to estimate the current state of a physical system, using less computation than has previously been thought necessary. As used here, relative measurements signifies measurements that yield information on the relationship between a later and an earlier state of the system. An important example of relative measurements arises in computer vision: Information on relative motion is extracted by comparing images taken at two different times. Relative measurements do not directly fit into standard Kalman filter theory, in which measurements are restricted to those indicative of only the current state of the system. One approach heretofore followed in utilizing relative measurements in Kalman filtering, denoted state augmentation, involves augmenting the state of the system at the earlier of two time instants and then propagating the state to the later time instant.While state augmentation is conceptually simple, it can also be computationally prohibitive because it doubles the number of states in the Kalman filter. When processing a relative measurement, if one were to follow the state-augmentation approach as practiced heretofore, one would find it necessary to propagate the full augmented state Kalman filter from the earlier time to the later time and then select out the reduced-order components. The main result of the study reported here is proof of a property called reduced-order equivalence (ROE). The main consequence of ROE is that it is not necessary to augment with the full state, but, rather, only the portion of the state that is explicitly used in the partial relative measurement. In other words, it suffices to select the reduced-order components first and then propagate the partial augmented state Kalman filter from the earlier time to the later time; the amount of computation needed to do this can be substantially less than that needed for propagating the full augmented Kalman state filter.
Methods and systems relating to an augmented virtuality environment
Nielsen, Curtis W; Anderson, Matthew O; McKay, Mark D; Wadsworth, Derek C; Boyce, Jodie R; Hruska, Ryan C; Koudelka, John A; Whetten, Jonathan; Bruemmer, David J
2014-05-20
Systems and methods relating to an augmented virtuality system are disclosed. A method of operating an augmented virtuality system may comprise displaying imagery of a real-world environment in an operating picture. The method may further include displaying a plurality of virtual icons in the operating picture representing at least some assets of a plurality of assets positioned in the real-world environment. Additionally, the method may include displaying at least one virtual item in the operating picture representing data sensed by one or more of the assets of the plurality of assets and remotely controlling at least one asset of the plurality of assets by interacting with a virtual icon associated with the at least one asset.
Napoli, C; Tafuri, S; Montenegro, L; Cassano, M; Notarnicola, A; Lattarulo, S; Montagna, M T; Moretti, B
2012-02-01
To evaluate the level of microbial contamination of air in operating theatres using active [i.e. surface air system (SAS)] and passive [i.e. index of microbial air contamination (IMA) and nitrocellulose membranes positioned near the wound] sampling systems. Sampling was performed between January 2010 and January 2011 in the operating theatre of the orthopaedics department in a university hospital in Southern Italy. During surgery, the mean bacterial loads recorded were 2232.9 colony-forming units (cfu)/m(2)/h with the IMA method, 123.2 cfu/m(3) with the SAS method and 2768.2 cfu/m(2)/h with the nitrocellulose membranes. Correlation was found between the results of the three methods. Staphylococcus aureus was detected in 12 of 60 operations (20%) with the membranes, five (8.3%) operations with the SAS method, and three operations (5%) with the IMA method. Use of nitrocellulose membranes placed near a wound is a valid method for measuring the microbial contamination of air. This method was more sensitive than the IMA method and was not subject to any calibration bias, unlike active air monitoring systems. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
2009-09-01
SAS Statistical Analysis Software SE Systems Engineering SEP Systems Engineering Process SHP Shaft Horsepower SIGINT Signals Intelligence......management occurs (OSD 2002). The Systems Engineering Process (SEP), displayed in Figure 2, is a comprehensive , iterative and recursive problem
A fault isolation method based on the incidence matrix of an augmented system
NASA Astrophysics Data System (ADS)
Chen, Changxiong; Chen, Liping; Ding, Jianwan; Wu, Yizhong
2018-03-01
A new approach is proposed for isolating faults and fast identifying the redundant sensors of a system in this paper. By introducing fault signal as additional state variable, an augmented system model is constructed by the original system model, fault signals and sensor measurement equations. The structural properties of an augmented system model are provided in this paper. From the viewpoint of evaluating fault variables, the calculating correlations of the fault variables in the system can be found, which imply the fault isolation properties of the system. Compared with previous isolation approaches, the highlights of the new approach are that it can quickly find the faults which can be isolated using exclusive residuals, at the same time, and can identify the redundant sensors in the system, which are useful for the design of diagnosis system. The simulation of a four-tank system is reported to validate the proposed method.
Narayanan, Ram M; Pooler, Richard K; Martone, Anthony F; Gallagher, Kyle A; Sherbondy, Kelly D
2018-02-22
This paper describes a multichannel super-heterodyne signal analyzer, called the Spectrum Analysis Solution (SAS), which performs multi-purpose spectrum sensing to support spectrally adaptive and cognitive radar applications. The SAS operates from ultrahigh frequency (UHF) to the S-band and features a wideband channel with eight narrowband channels. The wideband channel acts as a monitoring channel that can be used to tune the instantaneous band of the narrowband channels to areas of interest in the spectrum. The data collected from the SAS has been utilized to develop spectrum sensing algorithms for the budding field of spectrum sharing (SS) radar. Bandwidth (BW), average total power, percent occupancy (PO), signal-to-interference-plus-noise ratio (SINR), and power spectral entropy (PSE) have been examined as metrics for the characterization of the spectrum. These metrics are utilized to determine a contiguous optimal sub-band (OSB) for a SS radar transmission in a given spectrum for different modalities. Three OSB algorithms are presented and evaluated: the spectrum sensing multi objective (SS-MO), the spectrum sensing with brute force PSE (SS-BFE), and the spectrum sensing multi-objective with brute force PSE (SS-MO-BFE).
Pooler, Richard K.; Martone, Anthony F.; Gallagher, Kyle A.; Sherbondy, Kelly D.
2018-01-01
This paper describes a multichannel super-heterodyne signal analyzer, called the Spectrum Analysis Solution (SAS), which performs multi-purpose spectrum sensing to support spectrally adaptive and cognitive radar applications. The SAS operates from ultrahigh frequency (UHF) to the S-band and features a wideband channel with eight narrowband channels. The wideband channel acts as a monitoring channel that can be used to tune the instantaneous band of the narrowband channels to areas of interest in the spectrum. The data collected from the SAS has been utilized to develop spectrum sensing algorithms for the budding field of spectrum sharing (SS) radar. Bandwidth (BW), average total power, percent occupancy (PO), signal-to-interference-plus-noise ratio (SINR), and power spectral entropy (PSE) have been examined as metrics for the characterization of the spectrum. These metrics are utilized to determine a contiguous optimal sub-band (OSB) for a SS radar transmission in a given spectrum for different modalities. Three OSB algorithms are presented and evaluated: the spectrum sensing multi objective (SS-MO), the spectrum sensing with brute force PSE (SS-BFE), and the spectrum sensing multi-objective with brute force PSE (SS-MO-BFE). PMID:29470448
Message Passing vs. Shared Address Space on a Cluster of SMPs
NASA Technical Reports Server (NTRS)
Shan, Hongzhang; Singh, Jaswinder Pal; Oliker, Leonid; Biswas, Rupak
2000-01-01
The convergence of scalable computer architectures using clusters of PCs (or PC-SMPs) with commodity networking has become an attractive platform for high end scientific computing. Currently, message-passing and shared address space (SAS) are the two leading programming paradigms for these systems. Message-passing has been standardized with MPI, and is the most common and mature programming approach. However message-passing code development can be extremely difficult, especially for irregular structured computations. SAS offers substantial ease of programming, but may suffer from performance limitations due to poor spatial locality, and high protocol overhead. In this paper, we compare the performance of and programming effort, required for six applications under both programming models on a 32 CPU PC-SMP cluster. Our application suite consists of codes that typically do not exhibit high efficiency under shared memory programming. due to their high communication to computation ratios and complex communication patterns. Results indicate that SAS can achieve about half the parallel efficiency of MPI for most of our applications: however, on certain classes of problems SAS performance is competitive with MPI. We also present new algorithms for improving the PC cluster performance of MPI collective operations.
Markerless client-server augmented reality system with natural features
NASA Astrophysics Data System (ADS)
Ning, Shuangning; Sang, Xinzhu; Chen, Duo
2017-10-01
A markerless client-server augmented reality system is presented. In this research, the more extensive and mature virtual reality head-mounted display is adopted to assist the implementation of augmented reality. The viewer is provided an image in front of their eyes with the head-mounted display. The front-facing camera is used to capture video signals into the workstation. The generated virtual scene is merged with the outside world information received from the camera. The integrated video is sent to the helmet display system. The distinguishing feature and novelty is to realize the augmented reality with natural features instead of marker, which address the limitations of the marker, such as only black and white, the inapplicability of different environment conditions, and particularly cannot work when the marker is partially blocked. Further, 3D stereoscopic perception of virtual animation model is achieved. The high-speed and stable socket native communication method is adopted for transmission of the key video stream data, which can reduce the calculation burden of the system.
Congenital heart diseases in the boxer dog: A retrospective study of 105 cases (1998-2005).
Chetboul, V; Trollé, J M; Nicolle, A; Carlos Sampedrano, C; Gouni, V; Laforge, H; Benalloul, T; Tissier, R; Pouchelon, J-L
2006-09-01
Subaortic stenosis (SAS) is one of the most common congenital heart diseases (CHD) in dogs with Boxers being predominantly affected. However, the increasing availability of modern diagnostic imaging systems now allows a better assessment of cardiac morphology and function, thereby facilitating early detection of CHD in awake animals. In this context, the case records of Boxer dogs diagnosed with CHD using echocardiography combined with Doppler mode, were retrospectively reviewed (1998-2005). One hundred and five Boxers exhibiting either a single CHD (53/105, 50.5%) or association of several CHD (52/105, 49.5%) were included. The most common CHD was atrial septal defect (ASD) observed in 56.2% of these animals (59/105), followed by mitral dysplasia (58/105, 55.2%), and SAS (49/105, 46.7%). SAS was associated with one or two CHD in 29.5% of cases (31/105). Most of the dogs with a low intensity left heart base systolic murmur had an isolated ASD whereas most of the dogs with a similar but high intensity murmur had SAS, either isolated or associated with a concurrent CHD. The incidence of ASD and mitral dysplasia in Boxer dogs is higher than previously assumed, and ASD is a common cause of left heart base systolic murmur in this breed of dog. This confirms that the detection of such a murmur should not be used as the unique criterion for diagnostic confirmation of SAS.
The Glimm scheme for perfect fluids on plane-symmetric Gowdy spacetimes
NASA Astrophysics Data System (ADS)
Barnes, A. P.; Lefloch, P. G.; Schmidt, B. G.; Stewart, J. M.
2004-11-01
We propose a new, augmented formulation of the coupled Euler Einstein equations for perfect fluids on plane-symmetric Gowdy spacetimes. The unknowns of the augmented system are the density and velocity of the fluid and the first- and second-order spacetime derivatives of the metric. We solve the Riemann problem for the augmented system, allowing propagating discontinuities in both the fluid variables and the first- and second-order derivatives of the geometry coefficients. Our main result, based on Glimm's random choice scheme, is the existence of solutions with bounded total variation of the Euler Einstein equations, up to the first time where a blow-up singularity (unbounded first-order derivatives of the geometry coefficients) occurs. We demonstrate the relevance of the augmented system for numerical relativity. We also consider general vacuum spacetimes and solve a Riemann problem, by relying on a theorem by Rendall on the characteristic value problem for the Einstein equations.
An IBM PC-based math model for space station solar array simulation
NASA Technical Reports Server (NTRS)
Emanuel, E. M.
1986-01-01
This report discusses and documents the design, development, and verification of a microcomputer-based solar cell math model for simulating the Space Station's solar array Initial Operational Capability (IOC) reference configuration. The array model is developed utilizing a linear solar cell dc math model requiring only five input parameters: short circuit current, open circuit voltage, maximum power voltage, maximum power current, and orbit inclination. The accuracy of this model is investigated using actual solar array on orbit electrical data derived from the Solar Array Flight Experiment/Dynamic Augmentation Experiment (SAFE/DAE), conducted during the STS-41D mission. This simulator provides real-time simulated performance data during the steady state portion of the Space Station orbit (i.e., array fully exposed to sunlight). Eclipse to sunlight transients and shadowing effects are not included in the analysis, but are discussed briefly. Integrating the Solar Array Simulator (SAS) into the Power Management and Distribution (PMAD) subsystem is also discussed.
Tukiendorf, Andrzej; Mansournia, Mohammad Ali; Wydmański, Jerzy; Wolny-Rokicka, Edyta
2017-04-01
Background: Clinical datasets for epithelial ovarian cancer brain metastatic patients are usually small in size. When adequate case numbers are lacking, resulting estimates of regression coefficients may demonstrate bias. One of the direct approaches to reduce such sparse-data bias is based on penalized estimation. Methods: A re- analysis of formerly reported hazard ratios in diagnosed patients was performed using penalized Cox regression with a popular SAS package providing additional software codes for a statistical computational procedure. Results: It was found that the penalized approach can readily diminish sparse data artefacts and radically reduce the magnitude of estimated regression coefficients. Conclusions: It was confirmed that classical statistical approaches may exaggerate regression estimates or distort study interpretations and conclusions. The results support the thesis that penalization via weak informative priors and data augmentation are the safest approaches to shrink sparse data artefacts frequently occurring in epidemiological research. Creative Commons Attribution License
[The breast of the adolescent girl].
Bruant-Rodier, C; Dissaux, C; Baratte, A; Francois Fiquet, C; Bodin, F
2016-10-01
During adolescence, psychological and physical changes occur and breast takes a major place in the young woman body image. Except rare malign tumors, breast pathologies at this age are mainly benign or malformative. Malformative issues are revealed during breast growth, as isolated asymmetry or associated to other regional anomalies, with abnormal shape or volume of the breast, or even supernumerary breast. Therapeutic solutions will not differ from the ones used for adults. Breast lipofilling, recently admitted by plastic surgery community is an interesting tool that can be used on young women. Choosing the right technic depends on the initial problem. It comes at an early stage to offset hypoplasia resulting in a problem of asymmetry. It waits for breast stability in case of hypertrophy and for legal majority in case of breast augmentation using implants. Psychological impairment stays however a central issue and forces the surgeon to adapt to the individual and to his body change over time. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Rasch analysis for psychometric improvement of science attitude rating scales
NASA Astrophysics Data System (ADS)
Oon, Pey-Tee; Fan, Xitao
2017-04-01
Students' attitude towards science (SAS) is often a subject of investigation in science education research. Survey of rating scale is commonly used in the study of SAS. The present study illustrates how Rasch analysis can be used to provide psychometric information of SAS rating scales. The analyses were conducted on a 20-item SAS scale used in an existing dataset of The Trends in International Mathematics and Science Study (TIMSS) (2011). Data of all the eight-grade participants from Hong Kong and Singapore (N = 9942) were retrieved for analyses. Additional insights from Rasch analysis that are not commonly available from conventional test and item analyses were discussed, such as invariance measurement of SAS, unidimensionality of SAS construct, optimum utilization of SAS rating categories, and item difficulty hierarchy in the SAS scale. Recommendations on how TIMSS items on the measurement of SAS can be better designed were discussed. The study also highlights the importance of using Rasch estimates for statistical parametric tests (e.g. ANOVA, t-test) that are common in science education research for group comparisons.
Drosophila Ana2 is a conserved centriole duplication factor
Stevens, Naomi R.; Dobbelaere, Jeroen; Brunk, Kathrin; Franz, Anna
2010-01-01
In Caenorhabditis elegans, five proteins are required for centriole duplication: SPD-2, ZYG-1, SAS-5, SAS-6, and SAS-4. Functional orthologues of all but SAS-5 have been found in other species. In Drosophila melanogaster and humans, Sak/Plk4, DSas-6/hSas-6, and DSas-4/CPAP—orthologues of ZYG-1, SAS-6, and SAS-4, respectively—are required for centriole duplication. Strikingly, all three fly proteins can induce the de novo formation of centriole-like structures when overexpressed in unfertilized eggs. Here, we find that of eight candidate duplication factors identified in cultured fly cells, only two, Ana2 and Asterless (Asl), share this ability. Asl is now known to be essential for centriole duplication in flies, but no equivalent protein has been found in worms. We show that Ana2 is the likely functional orthologue of SAS-5 and that it is also related to the vertebrate STIL/SIL protein family that has been linked to microcephaly in humans. We propose that members of the SAS-5/Ana2/STIL family of proteins are key conserved components of the centriole duplication machinery. PMID:20123993
An Argument Against Augmenting the Lagrangean for Nonholonomic Systems
NASA Technical Reports Server (NTRS)
Roithmayr, Carlos M.; Hodges, Dewey H.
2009-01-01
Although it is known that correct dynamical equations of motion for a nonholonomic system cannot be obtained from a Lagrangean that has been augmented with a sum of the nonholonomic constraint equations weighted with multipliers, previous publications suggest otherwise. An example has been proposed in support of augmentation and purportedly demonstrates that an accepted method fails to produce correct equations of motion whereas augmentation leads to correct equations; this paper shows that in fact the opposite is true. The correct equations, previously discounted on the basis of a flawed application of the Newton-Euler method, are verified by using Kane's method and a new approach to determining the directions of constraint forces. A correct application of the Newton-Euler method reproduces valid equations.
Low cost photonic comb for sub-m/s wavelength calibration
NASA Astrophysics Data System (ADS)
Betters, Christopher H.; Hermouet, Maxime; Blanc, Thomas; Colless, James I.; Bland-Hawthorn, Joss; Kos, Janez; Leon-Saval, Sergio
2016-07-01
A fundamental limitation of precision radial velocity measurements is the accuracy and stability of the calibration source. Here we present a low-cost alternative to more complex laser metrology based systems that utilises a single-mode fibre Fabry-Perot etalon. There are three key elements on this photonic comb: i) an optical fibre etalon with thermo-electric coolers; ii) a Rubidium Saturation Absorption Spectroscopy (SAS) setup; and iii) an optical fibre switch system for simultaneous laser locking of the etalon. We simultaneously measure the Rubidium D2 transitions around 780.2 nm and the closest etalon line. A PID loop controls the etalon temperate to maintain the position of its peak with an RMS error of <10cm/s for 10 minute integration intervals in continous operation. The optical fibre switch system allows for a time multiplexed coupling of the etalon to a spectrograph and SAS system.
NASA Technical Reports Server (NTRS)
Rising, J. J.
1982-01-01
The L-1011 has been flight tested to demonstrate the relaxed static stability concept as a means of obtaining significant drag benefits to achieve a more energy efficient transport. Satisfactory handling qualities were maintained with the design of an active control horizontal tail for stability and control augmentation to allow operation of the L-1011 at centers of gravity close to the neutral point. Prior to flight test, a motion base visual flight simulator program was performed to optimize the augmentation system. The system was successfully demonstrated in a test program totaling forty-eight actual flight hours.
[A SAS marco program for batch processing of univariate Cox regression analysis for great database].
Yang, Rendong; Xiong, Jie; Peng, Yangqin; Peng, Xiaoning; Zeng, Xiaomin
2015-02-01
To realize batch processing of univariate Cox regression analysis for great database by SAS marco program. We wrote a SAS macro program, which can filter, integrate, and export P values to Excel by SAS9.2. The program was used for screening survival correlated RNA molecules of ovarian cancer. A SAS marco program could finish the batch processing of univariate Cox regression analysis, the selection and export of the results. The SAS macro program has potential applications in reducing the workload of statistical analysis and providing a basis for batch processing of univariate Cox regression analysis.
NASA Astrophysics Data System (ADS)
Zabelskii, D. V.; Vlasov, A. V.; Ryzhykau, Yu L.; Murugova, T. N.; Brennich, M.; Soloviov, D. V.; Ivankov, O. I.; Borshchevskiy, V. I.; Mishin, A. V.; Rogachev, A. V.; Round, A.; Dencher, N. A.; Büldt, G.; Gordeliy, V. I.; Kuklin, A. I.
2018-03-01
The method of small angle scattering (SAS) is widely used in the field of biophysical research of proteins in aqueous solutions. Obtaining low-resolution structure of proteins is still a highly valuable method despite the advances in high-resolution methods such as X-ray diffraction, cryo-EM etc. SAS offers the unique possibility to obtain structural information under conditions close to those of functional assays, i.e. in solution, without different additives, in the mg/mL concentration range. SAS method has a long history, but there are still many uncertainties related to data treatment. We compared 1D SAS profiles of apoferritin obtained by X-ray diffraction (XRD) and SAS methods. It is shown that SAS curves for X-ray diffraction crystallographic structure of apoferritin differ more significantly than it might be expected due to the resolution of the SAS instrument. Extrapolation to infinite dilution (EID) method does not sufficiently exclude dimerization and oligomerization effects and therefore could not guarantee total absence of dimers account in the final SAS curve. In this study, we show that EID SAXS, EID SANS and SEC-SAXS methods give complementary results and when they are used all together, it allows obtaining the most accurate results and high confidence from SAS data analysis of proteins.
Residual veterinary antibiotics in pig excreta after oral administration of sulfonamides.
Qiu, Jinrong; Zhao, Tao; Liu, Qingyun; He, Jinhua; He, Dechun; Wu, Genyi; Li, Yongtao; Jiang, Chengai; Xu, Zhencheng
2016-04-01
Sulfonamides (SAs) are applied widely as feed additives in the farming of livestock and poultry. It can lead to the excretion of large amounts of SAs in manure and result in persistent environmental pollution. We evaluated the fate of four SAs, sulfamerazine (SM1), sulfachloropyridazine (SCP), sulfadimoxine (SDM') and sulfaquinoxaline (SQ), from oral administration to excretion in urine and feces in pigs. The four SAs were added to homemade feed to make them reach the required concentration gradient, which were 0, 50 and 100 mg/kg (low, normal and high concentrations, respectively). In different treatments, excretions of the four SAs were 35.68-86.88 %. With regard to total excretion, the order was SQ > SCP > SM1 > SDM' for all treatments. The concentration of SAs in the feed had significant effects on the amount of the four SAs excreted every day. The concentration of SAs in feces and in the urine for different treatments was 15.03-26.55 and 14.54-69.22 %, respectively. In each treatment, excretions of SCP, SDM' and SQ in feces were lower than that in urine. The four SAs remained longer in urine than in feces. Excretions in urine and feces were lower if SAs were administered orally rather than by injection.
DOT National Transportation Integrated Search
2000-07-01
This report summarizes Global Positioning System (GPS) technology and its augmentation-related activities within State and local transportation agencies. In general, the following items are addressed for each State that participated in this investiga...
First report of sasX-positive methicillin-resistant Staphylococcus aureus in Japan.
Nakaminami, Hidemasa; Ito, Teruyo; Han, Xiao; Ito, Ayumu; Matsuo, Miki; Uehara, Yuki; Baba, Tadashi; Hiramatsu, Keiichi; Noguchi, Norihisa
2017-09-01
SasX is a known virulence factor of Staphylococcus aureus involved in colonisation and immune evasion of the bacterium. The sasX gene, which is located on the ϕSPβ prophage, is frequently found in the sequence type (ST) 239 S. aureus lineage, which is the predominant healthcare-associated clone in Asian countries. In Japan, ST239 clones have rarely been identified, and sasX-positive strains have not been reported to date. Here, we report the first identification of 18 sasX-positive methicillin-resistant S. aureus (MRSA) strains in Japanese hospitals between 2009 and 2011. All sasX-positive isolates belonged to an ST239-staphylococcal cassette chromosome mec type III (ST239-III) lineage. However, we were unable to identify additional sasX-positive MRSA strains from 2012 to 2016, indicating that the small epidemic of sasX-positive isolates observed in this study was temporary. The sequence surrounding sasX in the strain TOHH628 lacked 51 genes that encode phage packaging and structural proteins, and no bacteriophage was induced by mitomycin C. Additionally, in the TOHH628 strain, the region (64.6 kb) containing sasX showed high identity to the ϕSPβ-like element (71.3 kb) of the Taiwanese MRSA strain Z172. The data strongly suggest that the present sasX-positive isolates found in Japanese hospitals were transmitted incidentally from other countries. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Augmented reality application for industrial non-destructive inspection training
NASA Astrophysics Data System (ADS)
Amza, Catalin Gheorghe; Zapciu, Aurelian; Teodorescu, Octav
2018-02-01
Such a technology - Augmented Reality (AR) has great potential of use, especially for training purposes of new operators on using expensive equipment. In this context, the paper presents an augmented reality training system developed for phased-array ultrasonic non-destructive testing (NDT) equipment. The application has been developed using Unity 5.6.0 game-engine platform integrated with Vuforia sdk toolkit for devices with Android operating system. The test results performed by several NDT operators showed good results, thus proving the potential of using the application in the industrial field.
Augmented Reality Comes to Physics
ERIC Educational Resources Information Center
Buesing, Mark; Cook, Michael
2013-01-01
Augmented reality (AR) is a technology used on computing devices where processor-generated graphics are rendered over real objects to enhance the sensory experience in real time. In other words, what you are really seeing is augmented by the computer. Many AR games already exist for systems such as Kinect and Nintendo 3DS and mobile apps, such as…
NASA Astrophysics Data System (ADS)
Dunn, James P.; Rolland, James L.; Grim, James S.; Machado, Reinaldo M.; Hartz, Christopher L.
2006-11-01
A beta level evaluation of the GASGUARD® SAS GGT Arsine ion implant dopant supply developed by Air Products and Chemicals, Inc. was conducted by Atmel Corporation. The evaluation included characterization of the normalized wafer yield, mass spectra, ionization efficiency, flow rate, beam current, extraction of usable material and cylinder lifetime. This new and novel sub-atmospheric dopant gas delivery system utilizes a unique electrochemical process, which can generate, on demand, high flows of arsine at a constant 400 torr pressure while limiting net inventory of arsine to only 1 gram. This paper illustrates how Atmel Corporation evaluated and released this new arsine dopant delivery system for commercial production and verified high delivery capacity, resulting in reduced gas costs and increased cylinder life compared to the traditional adsorbent based technology.
Biological Small Angle Scattering: Techniques, Strategies and Tips
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaudhuri, Barnali; Muñoz, Inés G.; Urban, Volker S.
This book provides a clear, comprehensible and up-to-date description of how Small Angle Scattering (SAS) can help structural biology researchers. SAS is an efficient technique that offers structural information on how biological macromolecules behave in solution. SAS provides distinct and complementary data for integrative structural biology approaches in combination with other widely used probes, such as X-ray crystallography, Nuclear magnetic resonance, Mass spectrometry and Cryo-electron Microscopy. The development of brilliant synchrotron small-angle X-ray scattering (SAXS) beam lines has increased the number of researchers interested in solution scattering. SAS is especially useful for studying conformational changes in proteins, highly flexible proteins,more » and intrinsically disordered proteins. Small-angle neutron scattering (SANS) with neutron contrast variation is ideally suited for studying multi-component assemblies as well as membrane proteins that are stabilized in surfactant micelles or vesicles. SAS is also used for studying dynamic processes of protein fibrillation in amyloid diseases, and pharmaceutical drug delivery. The combination with size-exclusion chromatography further increases the range of SAS applications.The book is written by leading experts in solution SAS methodologies. The principles and theoretical background of various SAS techniques are included, along with practical aspects that range from sample preparation to data presentation for publication. Topics covered include techniques for improving data quality and analysis, as well as different scientific applications of SAS. With abundant illustrations and practical tips, we hope the clear explanations of the principles and the reviews on the latest progresses will serve as a guide through all aspects of biological solution SAS.The scope of this book is particularly relevant for structural biology researchers who are new to SAS. Advanced users of the technique will find it helpful for exploring the diversity of solution SAS methods and applications.« less
NASA Astrophysics Data System (ADS)
Zhao, Shouwei; Zhang, Yong; Zhou, Bin; Ma, Dongxi
2014-09-01
Interaction is one of the key techniques of augmented reality (AR) maintenance guiding system. Because of the complexity of the maintenance guiding system's image background and the high dimensionality of gesture characteristics, the whole process of gesture recognition can be divided into three stages which are gesture segmentation, gesture characteristic feature modeling and trick recognition. In segmentation stage, for solving the misrecognition of skin-like region, a segmentation algorithm combing background mode and skin color to preclude some skin-like regions is adopted. In gesture characteristic feature modeling of image attributes stage, plenty of characteristic features are analyzed and acquired, such as structure characteristics, Hu invariant moments features and Fourier descriptor. In trick recognition stage, a classifier based on Support Vector Machine (SVM) is introduced into the augmented reality maintenance guiding process. SVM is a novel learning method based on statistical learning theory, processing academic foundation and excellent learning ability, having a lot of issues in machine learning area and special advantages in dealing with small samples, non-linear pattern recognition at high dimension. The gesture recognition of augmented reality maintenance guiding system is realized by SVM after the granulation of all the characteristic features. The experimental results of the simulation of number gesture recognition and its application in augmented reality maintenance guiding system show that the real-time performance and robustness of gesture recognition of AR maintenance guiding system can be greatly enhanced by improved SVM.
NASA Astrophysics Data System (ADS)
Bazhenova, E.; Zarayskaya, Y.; Wigley, R. A.; Anderson, R.; Falconer, R. K. H.; Kearns, T.; Martin, T.; Minami, H.; Roperez, J.; Rosedee, A.; Sade, H.; Seeboruth, S.; Simpson, B.; Sumiyoshi, M.; Tinmouth, N.; Zwolak, K.
2017-12-01
In preparation for the XPRIZE 2017 Round 1, a new sea-floor mapping system has been assembled based on an Unmanned Surface Vessel (USV) coupled with an Autonomous Underwater Vehicle (AUV). USV operation allows reducing logistics costs, while the AUV provides enhanced maneuverability and high accuracy of stabilization for the mapping missions. The AUV is equipped with a high-resolution interferometric synthetic aperture sonar (HISAS) and a multibeam sonar (MBES), covering a wide bathymetry swath and the nadir, respectively. Typically operating at 20 to 40 m altitude, the HISAS is capable of providing SAS imagery with 4 x 4 cm resolution and bathymetry with 40 x 40 cm resolution throughout the swath. Smaller areas of interest (50 x 50 m) can be further examined using the Spot processing technique, to produce SAS imagery with 2 x 2 cm resolution and high- resolution SAS bathymetry with 5 x 5 cm resolution. This allows multi-aspect imaging and examination of seabed geological features at different scales. Advanced data post-processing can be performed to produce 3D images of objects and explore their structure using the shadow contrast and shape. Being an interferometric system, the HISAS collects data for both imagery and bathymetry in the same swath. This improves the robustness for SAS in areas with significant relief. In the standard survey mode, the HISAS can typically collect SAS data at 2.6 km2/hr over relatively flat ground. Another limiting factor to the HISAS data coverage and quality is the vehicle stability influenced by downslope and cross currents and the resulting vehicle's speed. From experience, the best coverage occurs at a vehicle speed of around 2 m/s. At slower speeds the vehicle starts to lose steerage leading to degradation of tracking and navigation performance, which harms the focusing algorithm that creates the SAS data. For the AUV mission planning in unknown areas or in case of highly variable conditions at the study site, MBES reconnaissance data can be acquired at higher altitudes prior to running the AUV close to the seabed. Additionally, the MBES is used to collect the acoustic bottom reflectivity (backscatter) data, which allows further sea-floor characterization and potentially description of sediment types and marine bottom habitats, such as coral reefs, deep sea hydrothermal vents etc.
NASA Technical Reports Server (NTRS)
Sevart, F. D.; Patel, S. M.; Wattman, W. J.
1972-01-01
Testing and evaluation of stability augmentation systems for aircraft flight control were conducted. The flutter suppression system analysis of a scale supersonic transport wing model is described. Mechanization of the flutter suppression system is reported. The ride control synthesis for the B-52 aeroelastic model is discussed. Model analyses were conducted using equations of motion generated from generalized mass and stiffness data.
Augmentative and Alternative Communication in the Early Childhood Years
ERIC Educational Resources Information Center
Hanline, Mary Frances; Nunes, Debora; Worthy, M. Brandy
2007-01-01
Augmentative and alternative communication (AAC) systems provide individuals unable to communicate effectively with speech a method of communicating. The choice and use of an AAC system is a complex and challenging process. It is best accomplished within a collaborative team model involving family members, child care providers and teachers,…
SAS-6 assembly templated by the lumen of cartwheel-less centrioles precedes centriole duplication
Fong, Chii Shyang; Kim, Minhee; Yang, T. Tony; Liao, Jung-Chi; Tsou, Meng-Fu Bryan
2014-01-01
SUMMARY Centrioles are 9-fold symmetric structures duplicating once per cell cycle. Duplication involves self-oligomerization of the centriolar protein SAS-6, but how the 9-fold symmetry is invariantly established remains unclear. Here, we found that SAS-6 assembly can be shaped by preexisting (or mother) centrioles. During S phase, SAS-6 molecules are first recruited to the proximal lumen of the mother centriole, adopting a cartwheel-like organization through interactions with the luminal wall, rather than via their self-oligomerization activity. The removal or release of luminal SAS-6 requires Plk4 and the cartwheel protein STIL. Abolishing either the recruitment or the removal of luminal SAS-6 hinders SAS-6 (or centriole) assembly at the outside wall of mother centrioles. After duplication, the lumen of engaged mother centrioles becomes inaccessible to SAS-6, correlating with a block for re-duplication. These results lead to a proposed model that centrioles may duplicate via a template-based process to preserve their geometry and copy number. PMID:25017693
Negahban, Hossein; Mohtasebi, Elham; Goharpey, Shahin
2015-01-01
The aim of this methodological study was to cross-culturally translate the Shoulder Activity Scale (SAS) into the Persian and determine its clinimetric properties including reliability, validity, and responsiveness in patients with shoulder disorders. Persian version of the SAS was obtained after standard forward-backward translation. Three questionnaires were completed by the respondents: SAS, shoulder pain and disability index (SPADI), and Short-Form 36 Health Survey (SF-36). The patients completed the SAS, 1 week after the first visit to evaluate the test-retest reliability. Construct validity was evaluated by examining the associations between the scores on the SAS and the scores obtained from the SPADI, SF-36, and age of the patients. To assess responsiveness, data were collected in the first visit and then again after 4 weeks physiotherapy intervention. Test-retest reliability and internal consistency were assessed using Intra-class Correlation Coefficient (ICC) and Cronbach's alpha, respectively. To evaluate construct validity, Spearman's rank correlation was used. The ability of the SAS to detect changes was evaluated by the receiver-operating characteristics method. No problem or language difficulties were reported during translation process. Test-retest reliability of the SAS was excellent with an ICC of 0.98. Also, the marginal Cronbach's alpha level of 0.64 was obtained. The correlation between the SAS and the SPADI was low, proving divergent validity, whereas the correlations between the SAS and the SF-36/age were moderate proving convergent validity. A marginally acceptable responsiveness was achieved for the Persian SAS. The study provides some evidences to support the test-retest reliability, internal consistency, construct validity, and responsiveness of the Persian version of the SAS in patients with shoulder disorders. Therefore, it seems that this instrument is a useful measure of shoulder activity level in research setting and clinical practice. The shoulder activity scale (SAS) is a reliable, valid, and responsive measure of shoulder activity level in Persian-speaking patients with different shoulder disorders. The results on clinimetric properties of the Persian SAS are comparable with its original, English version. Persian version of the SAS can be used in "clinical" and "research" settings of patients with shoulder disorders.
H2OTSTUF: Appropriate Operating Regimes for Magnetohydrodynamic Augmentation
NASA Technical Reports Server (NTRS)
Jones, Jonathan E.; Hawk, Clark W.
1998-01-01
A trade study of magnetohydrodynamic (MHD) augmented propulsion reveals a unique operating regime at lower thrust levels. Substantial mass savings are realized over conventional chemical, solar, and electrical propulsion concepts when MHD augmentation is used to obtain optimal I(sub sp). However, trip times for the most conservative estimates of power plant specific impulse and accelerator efficiency may be prohibitively long. Quasi-one-dimensional calculations show that a solar or nuclear thermal system augmented by MHD can provide competitive performance while utilizing a diverse range of propellants including water, which is available from the Space Shuttle, the Moon, asteroids, and various moons and planets within our solar system. The use of in-situ propellants will reduce costs of space operations as well as enable human exploration of our Solar System. The following conclusions can be drawn from the results of the mission trade study: (1) There exists a maximum thrust or mass flow rate above which MHD augmentation increases the initial mass in low earth orbit (LEO); (2) Mass saving of over 50% can be realized for unique combination of solar/MHD systems; (3) Trip times for systems utilizing current power supply technology may be prohibitively long. Theoretical predictions of MHD performance for in space propulsion systems show that improved efficiencies can reduce trip times to acceptable levels; (4) Long trip times indicative of low thrust systems can be shortened by an increase in the MHD accelerator efficiency or a decrease in the specific mass of the power supply and power processing unit; and (5) As for all propulsion concepts, missions with larger (Delta)v's benefit more from the increased specific impulse resulting from MHD augmentation. Using a quasi-one-dimensional analysis, the required operating conditions for a MHD accelerator to reach acceptable efficiencies are outlined. This analysis shows that substantial non-equilibrium ionization is desirable.
Improvements to information management systems simulator
NASA Technical Reports Server (NTRS)
Bilek, R. W.
1972-01-01
The performance of personnel in the augmentation and improvement of the interactive IMSIM information management simulation model is summarized. With this augmented model, NASA now has even greater capabilities for the simulation of computer system configurations, data processing loads imposed on these configurations, and executive software to control system operations. Through these simulations, NASA has an extremely cost effective capability for the design and analysis of computer-based data management systems.
Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego
2014-03-01
To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the surgeon's confidence, as well as surgical safety, efficiency, and precision by filtering tremor. The integration of augmented reality may be valuable for surgeons dealing with complex cases of congenital anatomic abnormality, for revision cochlear implant with distorted anatomy and poorly pneumatized mastoids, and as a method of interactive teaching. Further research into the cost-benefit ratio of da Vinci Si-assisted otologic surgery, as well as refinements of the proposed workflow, are required before considering clinical studies.
Patient-specific finite element modeling for femoral bone augmentation
Basafa, Ehsan; Armiger, Robert S.; Kutzer, Michael D.; Belkoff, Stephen M.; Mears, Simon C.; Armand, Mehran
2015-01-01
The aim of this study was to provide a fast and accurate finite element (FE) modeling scheme for predicting bone stiffness and strength suitable for use within the framework of a computer-assisted osteoporotic femoral bone augmentation surgery system. The key parts of the system, i.e. preoperative planning and intraoperative assessment of the augmentation, demand the finite element model to be solved and analyzed rapidly. Available CT scans and mechanical testing results from nine pairs of osteoporotic femur bones, with one specimen from each pair augmented by polymethylmethacrylate (PMMA) bone cement, were used to create FE models and compare the results with experiments. Correlation values of R2 = 0.72–0.95 were observed between the experiments and FEA results which, combined with the fast model convergence (~3 min for ~250,000 degrees of freedom), makes the presented modeling approach a promising candidate for the intended application of preoperative planning and intraoperative assessment of bone augmentation surgery. PMID:23375663
Validity of Simpson-Angus Scale (SAS) in a naturalistic schizophrenia population.
Janno, Sven; Holi, Matti M; Tuisku, Katinka; Wahlbeck, Kristian
2005-03-17
Simpson-Angus Scale (SAS) is an established instrument for neuroleptic-induced parkinsonism (NIP), but its statistical properties have been studied insufficiently. Some shortcomings concerning its content have been suggested as well. According to a recent report, the widely used SAS mean score cut-off value 0.3 of for NIP detection may be too low. Our aim was to evaluate SAS against DSM-IV diagnostic criteria for NIP and objective motor assessment (actometry). Ninety-nine chronic institutionalised schizophrenia patients were evaluated during the same interview by standardised actometric recording and SAS. The diagnosis of NIP was based on DSM-IV criteria. Internal consistency measured by Cronbach's alpha, convergence to actometry and the capacity for NIP case detection were assessed. Cronbach's alpha for the scale was 0.79. SAS discriminated between DSM-IV NIP and non-NIP patients. The actometric findings did not correlate with SAS. ROC-analysis yielded a good case detection power for SAS mean score. The optimal threshold value of SAS mean score was between 0.65 and 0.95, i.e. clearly higher than previously suggested threshold value. We conclude that SAS seems a reliable and valid instrument. The previously commonly used cut-off mean score of 0.3 has been too low resulting in low specificity, and we suggest a new cut-off value of 0.65, whereby specificity could be doubled without loosing sensitivity.
Validity of Simpson-Angus Scale (SAS) in a naturalistic schizophrenia population
Janno, Sven; Holi, Matti M; Tuisku, Katinka; Wahlbeck, Kristian
2005-01-01
Background Simpson-Angus Scale (SAS) is an established instrument for neuroleptic-induced parkinsonism (NIP), but its statistical properties have been studied insufficiently. Some shortcomings concerning its content have been suggested as well. According to a recent report, the widely used SAS mean score cut-off value 0.3 of for NIP detection may be too low. Our aim was to evaluate SAS against DSM-IV diagnostic criteria for NIP and objective motor assessment (actometry). Methods Ninety-nine chronic institutionalised schizophrenia patients were evaluated during the same interview by standardised actometric recording and SAS. The diagnosis of NIP was based on DSM-IV criteria. Internal consistency measured by Cronbach's α, convergence to actometry and the capacity for NIP case detection were assessed. Results Cronbach's α for the scale was 0.79. SAS discriminated between DSM-IV NIP and non-NIP patients. The actometric findings did not correlate with SAS. ROC-analysis yielded a good case detection power for SAS mean score. The optimal threshold value of SAS mean score was between 0.65 and 0.95, i.e. clearly higher than previously suggested threshold value. Conclusion We conclude that SAS seems a reliable and valid instrument. The previously commonly used cut-off mean score of 0.3 has been too low resulting in low specificity, and we suggest a new cut-off value of 0.65, whereby specificity could be doubled without loosing sensitivity. PMID:15774006
Wall, Richard J; Roques, Magali; Katris, Nicholas J; Koreny, Ludek; Stanway, Rebecca R; Brady, Declan; Waller, Ross F; Tewari, Rita
2016-06-24
The SAS6-like (SAS6L) protein, a truncated paralogue of the ubiquitous basal body/centriole protein SAS6, has been characterised recently as a flagellum protein in trypanosomatids, but associated with the conoid in apicomplexan Toxoplasma. The conoid has been suggested to derive from flagella parts, but is thought to have been lost from some apicomplexans including the malaria-causing genus Plasmodium. Presence of SAS6L in Plasmodium, therefore, suggested a possible role in flagella assembly in male gametes, the only flagellated stage. Here, we have studied the expression and role of SAS6L throughout the Plasmodium life cycle using the rodent malaria model P. berghei. Contrary to a hypothesised role in flagella, SAS6L was absent during gamete flagellum formation. Instead, SAS6L was restricted to the apical complex in ookinetes and sporozoites, the extracellular invasive stages that develop within the mosquito vector. In these stages SAS6L forms an apical ring, as we show is also the case in Toxoplasma tachyzoites. The SAS6L ring was not apparent in blood-stage invasive merozoites, indicating that the apical complex is differentiated between the different invasive forms. Overall this study indicates that a conoid-associated apical complex protein and ring structure is persistent in Plasmodium in a stage-specific manner.
Li, Aihua; Roy, Sarah H; Nattie, Eugene E
2016-09-01
Activation of central chemoreceptors by CO2 increases sympathetic nerve activity (SNA), arterial blood pressure (ABP) and breathing. These effects are exaggerated in spontaneously hypertensive rats (SHRs), resulting in an augmented CO2 chemoreflex that affects both breathing and ABP. The augmented CO2 chemoreflex and the high ABP are measureable in young SHRs (postnatal day 30-58) and become greater in adult SHRs. Blockade of orexin receptors can normalize the augmented CO2 chemoreflex and the high ABP in young SHRs and normalize the augmented CO2 chemoreflex and significantly lower the high ABP in adult SHRs. In the hypothalamus, SHRs have more orexin neurons, and a greater proportion of them increase their activity with CO2 . The orexin system is overactive in SHRs and contributes to the augmented CO2 chemoreflex and hypertension. Modulation of the orexin system may be beneficial in the treatment of neurogenic hypertension. Activation of central chemoreceptors by CO2 increases arterial blood pressure (ABP), sympathetic nerve activity and breathing. In spontaneously hypertensive rats (SHRs), high ABP is associated with enhanced sympathetic nerve activity and peripheral chemoreflexes. We hypothesized that an augmented CO2 chemoreflex and overactive orexin system are linked with high ABP in both young (postnatal day 30-58) and adult SHRs (4-6 months). Our main findings are as follows. (i) An augmented CO2 chemoreflex and higher ABP in SHRs are measureable at a young age and increase in adulthood. In wakefulness, the ventilatory response to normoxic hypercapnia is higher in young SHRs (mean ± SEM: 179 ± 11% increase) than in age-matched normotensive Wistar-Kyoto rats (114 ± 9% increase), but lower than in adult SHRs (226 ± 10% increase; P < 0.05). The resting ABP is higher in young SHRs (122 ± 5 mmHg) than in age-matched Wistar-Kyoto rats (99 ± 5 mmHg), but lower than in adult SHRs (152 ± 4 mmHg; P < 0.05). (ii) Spontaneously hypertensive rats have more orexin neurons and more CO2 -activated orexin neurons in the hypothalamus. (iii) Antagonism of orexin receptors with a dual orexin receptor antagonist, almorexant, normalizes the augmented CO2 chemoreflex in young and adult SHRs and the high ABP in young SHRs and significantly lowers ABP in adult SHRs. (iv) Attenuation of peripheral chemoreflexes by hyperoxia does not abolish the augmented CO2 chemoreflex (breathing and ABP) in SHRs, which indicates an important role for the central chemoreflex. We suggest that an overactive orexin system may play an important role in the augmented central CO2 chemoreflex and in the development of hypertension in SHRs. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
NASA Technical Reports Server (NTRS)
Edwards, J. W.; Deets, D. A.
1975-01-01
A cost-effective approach to flight testing advanced control concepts with remotely piloted vehicles is described. The approach utilizes a ground based digital computer coupled to the remotely piloted vehicle's motion sensors and control surface actuators through telemetry links to provide high bandwidth feedback control. The system was applied to the control of an unmanned 3/8-scale model of the F-15 airplane. The model was remotely augmented; that is, the F-15 mechanical and control augmentation flight control systems were simulated by the ground-based computer, rather than being in the vehicle itself. The results of flight tests of the model at high angles of attack are discussed.
Passive-performance, analysis, and upgrades of a 1-ton seismic attenuation system
NASA Astrophysics Data System (ADS)
Bergmann, G.; Mow-Lowry, C. M.; Adya, V. B.; Bertolini, A.; Hanke, M. M.; Kirchhoff, R.; Köhlenbeck, S. M.; Kühn, G.; Oppermann, P.; Wanner, A.; Westphal, T.; Wöhler, J.; Wu, D. S.; Lück, H.; Strain, K. A.; Danzmann, K.
2017-03-01
The 10 m prototype facility at the Albert-Einstein-institute (AEI) in Hanover, Germany, employs three large seismic attenuation systems to reduce mechanical motion. The AEI seismic-attenuation-system (AEI-SAS) uses mechanical anti-springs in order to achieve resonance frequencies below 0.5 Hz. This system provides passive isolation from ground motion by a factor of about 400 in the horizontal direction at 4 Hz and in the vertical direction at 9 Hz. The presented isolation performance is measured under vacuum conditions using a combination of commercial and custom-made inertial sensors. Detailed analysis of this performance led to the design and implementation of tuned dampers to mitigate the effect of the unavoidable higher order modes of the system. These dampers reduce RMS motion substantially in the frequency range between 10 and 100 Hz in 6 degrees of freedom. The results presented here demonstrate that the AEI-SAS provides substantial passive isolation at all the fundamental mirror-suspension resonances.
Schiegnitz, Eik; Al-Nawas, Bilal; Tegner, Alexander; Sagheb, Keyvan; Berres, Manfred; Kämmerer, Peer W; Wagner, Wilfried
2016-08-01
Tapered implant designs aim to improve primary stability and implant survival in soft bone. However, respective clinical long-term data are scarce. Therefore, a clinical and radiological evaluation of the long-term success of a transgingival-supracrestal inserted tapered implant system with special emphasis on the influence of augmentation procedures was conducted. In a retrospective study design, all in the Department of Oral and Maxillofacial Surgery of the University Medical Centre, Mainz, Germany, between May 2002 and March 2012, placed tapered implants (Straumann TE®, Basel, Switzerland) were analyzed. In this time period, a total of one hundred ninety-seven tapered implants were inserted in 90 patients. For patients available for clinical recall, success criteria according to Albrektsson and Buser were evaluated. The in situ rate was 96.3% after an average time in situ of 62 ± 31 months. In one hundred twenty-seven sites, bone augmentation procedures were performed. Hereof, 96 sites were sinus augmentation procedures and 31 sites were alveolar ridge augmentations. For patients with sinus augmentation procedures, implant survival was 97.9% and for patients with alveolar ridge augmentations, implant survival was 93.5% after 5 years, indicating a higher implant survival for sinus augmentation, however not statistically different (p = .194). Implant diameter and timing of implant placement had no significant impact on implant survival (p > .05). Mean marginal bone loss was -0.50 ± 1.54 mm for patients receiving maxillary sinus augmentation and -1.16 ± 1.13 mm for patients with alveolar ridge augmentations, indicating a lower marginal bone loss in patients receiving maxillary sinus augmentation (p = .046). Implant success rates ranged between 88% and 92% after a mean follow-up of 6 years. Within the limits of the retrospective character of this study, the tapered soft tissue level implant showed especially in maxillary sinus augmentation promising long-term survival and success rates and a low peri-implant bone resorption compared with the literature. © 2015 Wiley Periodicals, Inc.
Lockheed L-1101 avionic flight control redundant systems
NASA Technical Reports Server (NTRS)
Throndsen, E. O.
1976-01-01
The Lockheed L-1011 automatic flight control systems - yaw stability augmentation and automatic landing - are described in terms of their redundancies. The reliability objectives for these systems are discussed and related to in-service experience. In general, the availability of the stability augmentation system is higher than the original design requirement, but is commensurate with early estimates. The in-service experience with automatic landing is not sufficient to provide verification of Category 3 automatic landing system estimated availability.
Hoogeslag, Roy A G; Brouwer, Reinoud W; Huis In 't Veld, Rianne; Stephen, Joanna M; Amis, Andrew A
2018-02-03
There is a lack of objective evidence investigating how previous non-augmented ACL suture repair techniques and contemporary augmentation techniques in ACL suture repair restrain anterior tibial translation (ATT) across the arc of flexion, and after cyclic loading of the knee. The purpose of this work was to test the null hypotheses that there would be no statistically significant difference in ATT after non-, static- and dynamic-augmented ACL suture repair, and they will not restore ATT to normal values across the arc of flexion of the knee after cyclic loading. Eleven human cadaveric knees were mounted in a test rig, and knee kinematics from 0° to 90° of flexion were recorded by use of an optical tracking system. Measurements were recorded without load and with 89-N tibial anterior force. The knees were tested in the following states: ACL-intact, ACL-deficient, non-augmented suture repair, static tape augmentation and dynamic augmentation after 10 and 300 loading cycles. Only static tape augmentation and dynamic augmentation restored ATT to values similar to the ACL-intact state directly postoperation, and maintained this after cyclic loading. However, contrary to dynamic augmentation, the ATT after static tape augmentation failed to remain statistically less than for the ACL-deficient state after cyclic loading. Moreover, after cyclic loading, ATT was significantly less with dynamic augmentation when compared to static tape augmentation. In contrast to non-augmented ACL suture repair and static tape augmentation, only dynamic augmentation resulted in restoration of ATT values similar to the ACL-intact knee and decreased ATT values when compared to the ACL-deficient knee immediately post-operation and also after cyclic loading, across the arc of flexion, thus allowing the null hypotheses to be rejected. This may assist healing of the ruptured ACL. Therefore, this study would support further clinical evaluation of dynamic augmentation of ACL repair.
Augmented reality in neurosurgery
Tagaytayan, Raniel; Kelemen, Arpad
2016-01-01
Neurosurgery is a medical specialty that relies heavily on imaging. The use of computed tomography and magnetic resonance images during preoperative planning and intraoperative surgical navigation is vital to the success of the surgery and positive patient outcome. Augmented reality application in neurosurgery has the potential to revolutionize and change the way neurosurgeons plan and perform surgical procedures in the future. Augmented reality technology is currently commercially available for neurosurgery for simulation and training. However, the use of augmented reality in the clinical setting is still in its infancy. Researchers are now testing augmented reality system prototypes to determine and address the barriers and limitations of the technology before it can be widely accepted and used in the clinical setting. PMID:29765445
Augmented reality in neurosurgery.
Tagaytayan, Raniel; Kelemen, Arpad; Sik-Lanyi, Cecilia
2018-04-01
Neurosurgery is a medical specialty that relies heavily on imaging. The use of computed tomography and magnetic resonance images during preoperative planning and intraoperative surgical navigation is vital to the success of the surgery and positive patient outcome. Augmented reality application in neurosurgery has the potential to revolutionize and change the way neurosurgeons plan and perform surgical procedures in the future. Augmented reality technology is currently commercially available for neurosurgery for simulation and training. However, the use of augmented reality in the clinical setting is still in its infancy. Researchers are now testing augmented reality system prototypes to determine and address the barriers and limitations of the technology before it can be widely accepted and used in the clinical setting.
ERIC Educational Resources Information Center
Ray, Jayanti
2015-01-01
Given the linguistic and cognitive demands of communication, adult Augmentative and Alternative Communication (AAC) users with acquired communication disorders may have difficulty using AAC systems consistently and effectively in "real-life" situations. The process of recommending AAC systems and strategies is an area of exploration,…
14 CFR 25.945 - Thrust or power augmentation system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Thrust or power augmentation system. 25.945 Section 25.945 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... must have an expansion space of not less than 2 percent of the tank capacity. It must be impossible to...
14 CFR 25.945 - Thrust or power augmentation system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Thrust or power augmentation system. 25.945 Section 25.945 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... must have an expansion space of not less than 2 percent of the tank capacity. It must be impossible to...
14 CFR 25.945 - Thrust or power augmentation system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Thrust or power augmentation system. 25.945 Section 25.945 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... must have an expansion space of not less than 2 percent of the tank capacity. It must be impossible to...
14 CFR 25.945 - Thrust or power augmentation system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Thrust or power augmentation system. 25.945 Section 25.945 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... must have an expansion space of not less than 2 percent of the tank capacity. It must be impossible to...
14 CFR 25.945 - Thrust or power augmentation system.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Thrust or power augmentation system. 25.945 Section 25.945 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... must have an expansion space of not less than 2 percent of the tank capacity. It must be impossible to...
Peer-Directed Communicative Interactions of Augmented Language Learners with Mental Retardation.
ERIC Educational Resources Information Center
Romski, Mary Ann; And Others
1994-01-01
Evaluation of naturally occurring peer-directed communicative interactions of 13 youth with moderate to severe mental retardation and little or no functional speech, who used the System for Augmenting Language as their primary means of communication, found that the system was an integral component of successful and effective conversations and…
The inertial attitude augmentation for ambiguity resolution in SF/SE-GNSS attitude determination.
Zhu, Jiancheng; Hu, Xiaoping; Zhang, Jingyu; Li, Tao; Wang, Jinling; Wu, Meiping
2014-06-26
The Unaided Single Frequency/Single Epoch Global Navigation Satellite System (SF/SE GNSS) model is the most challenging scenario for ambiguity resolution in the GNSS attitude determination application. To improve the performance of SF/SE-GNSS ambiguity resolution without excessive cost, the Micro-Electro-Mechanical System Inertial Measurement Unit (MEMS-IMU) is a proper choice for the auxiliary sensor that carries out the inertial attitude augmentation. Firstly, based on the SF/SE-GNSS compass model, the Inertial Derived Baseline Vector (IDBV) is defined to connect the MEMS-IMU attitude measurement with the SF/SE-GNSS ambiguity search space, and the mechanism of inertial attitude augmentation is revealed from the perspective of geometry. Then, through the quantitative description of model strength by Ambiguity Dilution of Precision (ADOP), two ADOPs are specified for the unaided SF/SE-GNSS compass model and its inertial attitude augmentation counterparts, respectively, and a sufficient condition is proposed for augmenting the SF/SE-GNSS model strength with inertial attitude measurement. Finally, in the framework of an integer aperture estimator with fixed failure rate, the performance of SF/SE-GNSS ambiguity resolution with inertial attitude augmentation is analyzed when the model strength is varying from strong to weak. The simulation results show that, in the SF/SE-GNSS attitude determination application, MEMS-IMU can satisfy the requirements of ambiguity resolution with inertial attitude augmentation.
The Inertial Attitude Augmentation for Ambiguity Resolution in SF/SE-GNSS Attitude Determination
Zhu, Jiancheng; Hu, Xiaoping; Zhang, Jingyu; Li, Tao; Wang, Jinling; Wu, Meiping
2014-01-01
The Unaided Single Frequency/Single Epoch Global Navigation Satellite System (SF/SE GNSS) model is the most challenging scenario for ambiguity resolution in the GNSS attitude determination application. To improve the performance of SF/SE-GNSS ambiguity resolution without excessive cost, the Micro-Electro-Mechanical System Inertial Measurement Unit (MEMS-IMU) is a proper choice for the auxiliary sensor that carries out the inertial attitude augmentation. Firstly, based on the SF/SE-GNSS compass model, the Inertial Derived Baseline Vector (IDBV) is defined to connect the MEMS-IMU attitude measurement with the SF/SE-GNSS ambiguity search space, and the mechanism of inertial attitude augmentation is revealed from the perspective of geometry. Then, through the quantitative description of model strength by Ambiguity Dilution of Precision (ADOP), two ADOPs are specified for the unaided SF/SE-GNSS compass model and its inertial attitude augmentation counterparts, respectively, and a sufficient condition is proposed for augmenting the SF/SE-GNSS model strength with inertial attitude measurement. Finally, in the framework of an integer aperture estimator with fixed failure rate, the performance of SF/SE-GNSS ambiguity resolution with inertial attitude augmentation is analyzed when the model strength is varying from strong to weak. The simulation results show that, in the SF/SE-GNSS attitude determination application, MEMS-IMU can satisfy the requirements of ambiguity resolution with inertial attitude augmentation. PMID:24971472
Development of augmented reality system for servicing electromechanical equipment
NASA Astrophysics Data System (ADS)
Zhukovskiy, Y.; Koteleva, N.
2018-05-01
Electromechanical equipment is widely used. It is used in industrial enterprises, in the spheres of public services, in everyday life, etc. Maintenance servicing of electromechanical equipment is an important part of its life cycle. High-quality and timely service can extend the life of the electromechanical equipment. The creation of special systems that simplify the process of servicing electromechanical equipment is an urgent task. Such systems can shorten the time for maintenance of electrical equipment, and, therefore, reduce the cost of maintenance in general. This article presents an analysis of information on the operation of service services for maintenance and repair of electromechanical equipment, identifies the list of services, and estimates the time required to perform basic service operations. The structure of the augmented reality system is presented, the ways of interaction of the augmented reality system with the automated control systems working at the enterprise are presented.
SAS-6 assembly templated by the lumen of cartwheel-less centrioles precedes centriole duplication.
Fong, Chii Shyang; Kim, Minhee; Yang, T Tony; Liao, Jung-Chi; Tsou, Meng-Fu Bryan
2014-07-28
Centrioles are 9-fold symmetric structures duplicating once per cell cycle. Duplication involves self-oligomerization of the centriolar protein SAS-6, but how the 9-fold symmetry is invariantly established remains unclear. Here, we found that SAS-6 assembly can be shaped by preexisting (or mother) centrioles. During S phase, SAS-6 molecules are first recruited to the proximal lumen of the mother centriole, adopting a cartwheel-like organization through interactions with the luminal wall, rather than via their self-oligomerization activity. The removal or release of luminal SAS-6 requires Plk4 and the cartwheel protein STIL. Abolishing either the recruitment or the removal of luminal SAS-6 hinders SAS-6 (or centriole) assembly at the outside wall of mother centrioles. After duplication, the lumen of engaged mother centrioles becomes inaccessible to SAS-6, correlating with a block for reduplication. These results lead to a proposed model that centrioles may duplicate via a template-based process to preserve their geometry and copy number. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Nooij, S. A. E.; Bos, J. E.; Groen, E. L.; Bles, W.; Ockels, W. J.
2007-09-01
During the first days in space, i.e., after a transition from 1G to 0G, more than 50% of the astro- (and cosmonauts) suffer from the Space Adaptation Syndrome (SAS).The symptoms of SAS, like nausea and dizziness, are especially provoked by head movements. Astronauts have mentioned close similarities between the symptoms of SAS and the symptoms they experienced after a 1 hour centrifuge run on Earth, i.e., after a transition from 3G to 1G (denoted by Sickness Induced by Centrifugation, SIC). During several space missions, we related susceptibility to SAS and to SIC in 11 astronauts and found 4 of them being susceptible to both SIC and SAS, and 7 being not susceptible to SIC nor to SAS. This correspondence in susceptibility suggests that SIC and SAS share the same underlying mechanism. To further study this mechanism, several vestibular parameters have been investigated (e.g. postural stability, vestibularly driven eye movements, subjective vertical). We found some striking changes in individual cases that are possibly due to the centrifuge run. However, the variability between subjects generally is very large, making physiological links to SIC and SAS still hard to find.
A Method for Estimating Costs and Benefits of Space Assembly and Servicing By Astronauts and Robots
NASA Technical Reports Server (NTRS)
Purves, Lloyd R.; Benfield, Mark (Technical Monitor)
2002-01-01
One aspect of designing future space missions is to determine whether Space Assembly and Servicing (SAS) is useful and, if so, what combination of robots and astronauts provides the most effective means of accomplishing it. Certain aspects of these choices, such as the societal value of developing the means for humans to live in space, do not lend themselves to quantification. However, other SAS costs and benefits can be quantified in a manner that can help select the most cost-effective SAS approach. Any space facility, whether it is assembled and serviced or not, entails an eventual replacement cost due to wear and obsolescence. Servicing can reduce this cost by limiting replacement to only failed or obsolete components. However, servicing systems, such as space robots, have their own logistics cost, and astronauts can have even greater logistics requirements. On the other hand, humans can be more capable than robots at performing dexterous and unstructured tasks, which can reduce logistics costs by allowing a reduction in mass of replacement components. Overall, the cost-effectiveness of astronaut SAS depends on its efficiency; and, if astronauts have to be wholly justified by their servicing usefulness, then the serviced space facility has to be large enough to fully occupy them.
Sleep apnoea syndromes and the cardiovascular system.
Pepperell, Justin C
2011-06-01
Management of SAS and cardiovascular disease risk should be closely linked. It is important to screen for cardiovascular disease risk in patients with SAS and vice versa. CSA/CSR may be improved by ventilation strategies in heart failure, but benefit remains to be proven. For OSA, although CPAP may reduce cardiovascular disease risk, its main benefit is symptom control. In the longer-term, CPAP should be used alongside standard cardiovascular risk reduction strategies including robust weight management programmes, with referral for bariatric surgery in appropriate cases. CPAP and NIV should be considered for acute admissions with decompensated cardiac failure.
Genetic evidence of subaortic stenosis in the Newfoundland dog.
Reist-Marti, S B; Dolf, G; Leeb, T; Kottmann, S; Kietzmann, S; Butenhoff, K; Rieder, S
2012-06-09
Subaortic stenosis (SAS) is a cardiac disorder with a narrowing of the descending aorta below the left ventricular outflow tract of the heart. It occurs in several species and breeds. The Newfoundland is one of the dog breeds where it is more common and usually leads to death at early adulthood. It is still discussed to which extent SAS has a genetic background and what its mode of inheritance could be. Extensive pedigree data comprising more than 230,000 Newfoundland dogs from the European and North American population reaching back to the 19th century including 6023 dogs with a SAS diagnosis were analysed for genetic factors influencing SAS affection. The incidence and prevalence of SAS in the analysed Newfoundland population sample were much higher than those reported in previous studies on smaller population samples. Assuming that some SAS-affected dogs remained undiscovered or were not reported, these figures may even be underestimated. SAS-affected Newfoundland dogs were more often inbred and closer related to each other than unaffected dogs, which is an indicator for a genetic background of SAS. The sex had no significant impact on SAS affectedness, pointing at an autosomal inheritance. The only simple mode of inheritance that fitted the data well was autosomal codominant with lethal homozygosity and a penetrance of 1/3 in the heterozygotes.
Experimental Investigations of Generalized Predictive Control for Tiltrotor Stability Augmentation
NASA Technical Reports Server (NTRS)
Nixon, Mark W.; Langston, Chester W.; Singleton, Jeffrey D.; Piatak, David J.; Kvaternik, Raymond G.; Bennett, Richard L.; Brown, Ross K.
2001-01-01
A team of researchers from the Army Research Laboratory, NASA Langley Research Center (LaRC), and Bell Helicopter-Textron, Inc. have completed hover-cell and wind-tunnel testing of a 1/5-size aeroelastically-scaled tiltrotor model using a new active control system for stability augmentation. The active system is based on a generalized predictive control (GPC) algorithm originally developed at NASA LaRC in 1997 for un-known disturbance rejection. Results of these investigations show that GPC combined with an active swashplate can significantly augment the damping and stability of tiltrotors in both hover and high-speed flight.
Augmented reality for anatomical education.
Thomas, Rhys Gethin; John, Nigel William; Delieu, John Michael
2010-03-01
The use of Virtual Environments has been widely reported as a method of teaching anatomy. Generally such environments only convey the shape of the anatomy to the student. We present the Bangor Augmented Reality Education Tool for Anatomy (BARETA), a system that combines Augmented Reality (AR) technology with models produced using Rapid Prototyping (RP) technology, to provide the student with stimulation for touch as well as sight. The principal aims of this work were to provide an interface more intuitive than a mouse and keyboard, and to evaluate such a system as a viable supplement to traditional cadaver based education.
Besharati Tabrizi, Leila; Mahvash, Mehran
2015-07-01
An augmented reality system has been developed for image-guided neurosurgery to project images with regions of interest onto the patient's head, skull, or brain surface in real time. The aim of this study was to evaluate system accuracy and to perform the first intraoperative application. Images of segmented brain tumors in different localizations and sizes were created in 10 cases and were projected to a head phantom using a video projector. Registration was performed using 5 fiducial markers. After each registration, the distance of the 5 fiducial markers from the visualized tumor borders was measured on the virtual image and on the phantom. The difference was considered a projection error. Moreover, the image projection technique was intraoperatively applied in 5 patients and was compared with a standard navigation system. Augmented reality visualization of the tumors succeeded in all cases. The mean time for registration was 3.8 minutes (range 2-7 minutes). The mean projection error was 0.8 ± 0.25 mm. There were no significant differences in accuracy according to the localization and size of the tumor. Clinical feasibility and reliability of the augmented reality system could be proved intraoperatively in 5 patients (projection error 1.2 ± 0.54 mm). The augmented reality system is accurate and reliable for the intraoperative projection of images to the head, skull, and brain surface. The ergonomic advantage of this technique improves the planning of neurosurgical procedures and enables the surgeon to use direct visualization for image-guided neurosurgery.
NASA Technical Reports Server (NTRS)
Chen, R. T. N.; Talbot, P. D.; Gerdes, R. M.; Dugan, D. C.
1978-01-01
A piloted simulation study assessed various levels of stability and control augmentation designed to improve the handling qualities of several helicopters in nap-of-the-earth (NOE) flight. Five basic single rotor helicopters - one teetering, two articulated, and two hingeless - which were found to have a variety of major deficiencies in a previous fixed-based simulator study were selected as baseline configurations. The stability and control augmentation systems (SCAS) include simple control augmentation systems (CAS) to decouple pitch and yaw responses due to collective input and to quicken the pitch and roll control responses; SCAS of rate command type designed to optimize the sensitivity and damping and to decouple the pitch-roll due to aircraft angular rate; and attitude command type SCAS. Pilot ratings and commentary are presented as well as performance data related to the task. SCAS control usage and their gain levels associated with specific rotor type are also discussed.
NASA Technical Reports Server (NTRS)
1980-01-01
Parasite drag reduction evaluation is composed of wind tunnel tests with a standard L-1011 tail and two reduced area tail configurations. Trim drag reduction is evaluated by rebalancing the airplane for relaxed static stability. This is accomplished by pumping water to tanks in the forward and aft of the airplane to acheive desired center of gravity location. Also, the L-1011 is modified to incorporate term and advanced augmented systems. By using advanced wings and aircraft relaxed static stability significant fuel savings can be realized. An airplane's dynamic stability becomes more sensitive for decreased tail size, relaxed static stability, and advanced wing configurations. Active control pitch augmentation will be used to acheive the required handling qualities. Flight tests will be performed to evaluate the pitch augmentation systems. The effect of elevator downrig on stabilizer/elevator hinge moments will be measured. For control system analysis, the normal acceleration feedback and pitch rate feedback are analyzed.
Death and Disability in Patients with Sleep Apnea - A Meta-analysis
Fonseca, Maria Inês Pires; Pereira, Telmo; Caseiro, Paulo
2015-01-01
Background Several studies have been attempting to ascertain the risks of Sleep Apnea Syndrome (SAS) and its morbidity and mortality. Objective The main objective was to verify whether SAS increases the risk of death; the secondary objective was to evaluate its morbidity in relation to cardiovascular disease and the number of days hospitalized. Methods A systematic review and a meta-analysis were performed of the published literature. The research focused on studies comparing the number of deaths in patients with untreated SAS and in patients with non-SAS. Results The meta-analysis was based on 13 articles, corresponding to a total of 13394 participants divided into two groups (non-SAS = 6631; SAS = 6763). The meta-analysis revealed a clear association of SAS with the occurrence of fatal events, where the presence of SAS corresponded to a 61% higher risk of total mortality (OR=1.61; CI: 1.43 - 1.81; p < 0.00001), while the risk of death from cardiac causes was 2.52 times higher in these patients (OR = 2.52; IC: 1.80 - 3.52; p < 0.00001). Similar results were obtained for mortality from other causes (OR = 1.68; CI: 1.08 - 2.61; p = 0.02). Resembling results were obtained in the remaining outcomes: non-fatal cardiovascular events were higher in the SAS group (OR = 2.46; IC: 1.80 - 3.36; p < 0.00001), the average number of days hospitalized was also higher in the SAS group (IV = 18.09; IC: 13.34 - 22.84; p < 0.00001). Conclusion The results show that untreated SAS significantly increases the risk of death, cardiovascular events and the average number of days hospitalized. PMID:25409880
Sobol, Julia B.; Gershengorn, ayley B.; Wunsch, Hannah; Li, Guohua
2014-01-01
Background Understanding intensive care unit (ICU) triage decisions for high-risk surgical patients may ultimately facilitate resource allocation and improve outcomes. The surgical Apgar score (SAS) is a simple score that uses intraoperative information on hemodynamics and blood loss to predict postoperative morbidity and mortality, with lower scores associated with worse outcomes. We hypothesized that the SAS would be associated with the decision to admit a patient to the ICU postoperatively. Methods Retrospective cohort study of adults undergoing major intra-abdominal surgery from 2003 to 2010 at an academic medical center. We calculated the SAS (0 – 10) for each patient based on intraoperative heart rate, mean arterial pressure, and estimated blood loss. Using logistic regression, we assessed the association of the SAS with the decision to admit a patient directly to the ICU after surgery. Results The cohort consisted of 8,501 patients, with 72.7% having a SAS of 7-10 and less than 5% a SAS of 0-4. A total of 8.7% of patients were transferred immediately to the ICU postoperatively. After multivariate adjustment, there was a strong association between the SAS and the decision to admit a patient to the ICU (adjusted odds ratio 14.41 [95% CI 6.88 – 30.19, P < 0.001] for SAS 0-2, 4.42 [95% CI 3.19 – 6.13, P <0.001] for SAS 3-4, and 2.60 [95% CI 2.08 – 3.24, P < 0.001] for SAS 5-6 compared with SAS 7-8). Conclusions The SAS is strongly associated with clinical decisions regarding immediate ICU admission after high-risk intra-abdominal surgery. These results provide an initial step towards understanding whether intraoperative hemodynamics and blood loss influence ICU triage for post-surgical patients. PMID:23744956
Leong, Hio Teng; Tsui, Sammi Sin Mei; Ng, Gabriel Yin-Fat; Fu, Siu Ngor
2016-12-01
To compare the reduction of subacromial space (SAS) during arm abduction between overhead athletes with and without rotator cuff (RC) tendinopathy, and to explore the relationship between the strength of scapular muscles with the SAS. Cross-sectional study. Sixty-six athletes (33 healthy and 33 with RC tendinopathy, mean age=22.3 years) participated in the study. Ultrasound measurement of the SAS with arm at 0°, 30° and 60° of shoulder abduction were taken, and the maximal isometric force in upper, middle and lower trapezius, and serratus anterior with manual muscle tests (MMT) were assessed using a handheld dynamometer. The change in SAS during arm abduction from 0° to 30° (SAS 0°-30° ), 30° to 60° (SAS 30°-60° ) and 0° to 60° (SAS 0°-60° ) was compared between groups. Differences in force produced with scapular muscles MMT between groups and relationships with reduction in SAS were explored. We found more reduction of the SAS during SAS 0°-30° in athletes with RC tendinopathy (0.44±1.22mm) than healthy athletes (-0.06±1.41mm) (p=0.045). Athletes with RC tendinopathy demonstrated significant decrease in all scapular muscles MMT strength when compared to their healthy counterparts (p<0.05). In healthy athletes, a lower middle and lower trapezius MMT strength were moderately associated with a greater reduction in SAS during 0° to 30° (r=-0.445, p=0.016 and r=-0.423, p=0.022, respectively) and 0° to 60° of shoulder abduction (r=-0.415, p=0.018 and r=-0.504, p=0.003, respectively). Athletes with RC tendinopathy demonstrated more reduction in the SAS during early arm abduction. Decreased strength of middle and lower trapezius was related to reduction of the SAS. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeung, Yu-Hong; Pothen, Alex; Halappanavar, Mahantesh
We present an augmented matrix approach to update the solution to a linear system of equations when the coefficient matrix is modified by a few elements within a principal submatrix. This problem arises in the dynamic security analysis of a power grid, where operators need to performmore » $N-x$ contingency analysis, i.e., determine the state of the system when up to $x$ links from $N$ fail. Our algorithms augment the coefficient matrix to account for the changes in it, and then compute the solution to the augmented system without refactoring the modified matrix. We provide two algorithms, a direct method, and a hybrid direct-iterative method for solving the augmented system. We also exploit the sparsity of the matrices and vectors to accelerate the overall computation. Our algorithms are compared on three power grids with PARDISO, a parallel direct solver, and CHOLMOD, a direct solver with the ability to modify the Cholesky factors of the coefficient matrix. We show that our augmented algorithms outperform PARDISO (by two orders of magnitude), and CHOLMOD (by a factor of up to 5). Further, our algorithms scale better than CHOLMOD as the number of elements updated increases. The solutions are computed with high accuracy. Our algorithms are capable of computing $N-x$ contingency analysis on a $778K$ bus grid, updating a solution with $x=20$ elements in $$1.6 \\times 10^{-2}$$ seconds on an Intel Xeon processor.« less
76 FR 35197 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-16
... access to the database is restricted to authorized System Administrators (SAs) only. Server access is..., examination and lesson grades, student academic status, curricula, course description. Authority for... student academic status; course and sub-course descriptions; produce course completion certificates and...
Augmented REality Sandtables (ARESs) Impact on Learning
2016-07-01
Disclaimers The findings in this report are not to be construed as an official Department of the Army position unless so designated by other authorized...The use of augmented reality ( AR ) to supplement training tools, specifically sand tables, can produce highly effective systems at relatively low...engagement and enhanced-scenario customization. The Augmented REality Sandtable ( ARES ) is projected to enhance training and retention of spatial
Recent Development of Augmented Reality in Surgery: A Review.
Vávra, P; Roman, J; Zonča, P; Ihnát, P; Němec, M; Kumar, J; Habib, N; El-Gendi, A
2017-01-01
The development augmented reality devices allow physicians to incorporate data visualization into diagnostic and treatment procedures to improve work efficiency, safety, and cost and to enhance surgical training. However, the awareness of possibilities of augmented reality is generally low. This review evaluates whether augmented reality can presently improve the results of surgical procedures. We performed a review of available literature dating from 2010 to November 2016 by searching PubMed and Scopus using the terms "augmented reality" and "surgery." Results . The initial search yielded 808 studies. After removing duplicates and including only journal articles, a total of 417 studies were identified. By reading of abstracts, 91 relevant studies were chosen to be included. 11 references were gathered by cross-referencing. A total of 102 studies were included in this review. The present literature suggest an increasing interest of surgeons regarding employing augmented reality into surgery leading to improved safety and efficacy of surgical procedures. Many studies showed that the performance of newly devised augmented reality systems is comparable to traditional techniques. However, several problems need to be addressed before augmented reality is implemented into the routine practice.
2015-11-30
Assessments for Efficient Evaluation of Auditory Situation Awareness Characteristics of Tactical Communications and Protective Systems (TCAPS) and Augmented...Hearing Protective Devices (HPDs) W81XWH-13-C-0193 John G. Casali, Ph.D, CPE & Kichol Lee, Ph.D Auditory Systems Lab, Industrial and Systems ...Suite 1 JBSA Lackland, TX 78236-9908 Approved for public release: distribution unlimited. The Virginia Tech Auditory Systems Laboratory (ASL
NASA Technical Reports Server (NTRS)
Finger, Herbert; Weeks, Bill
1985-01-01
This presentation discusses instrumentation that will be used for a specific event, which we hope will carry on to future events within the Space Shuttle program. The experiment is the Autogenic Feedback Training Experiment (AFTE) scheduled for Spacelab 3, currently scheduled to be launched in November, 1984. The objectives of the AFTE are to determine the effectiveness of autogenic feedback in preventing or reducing space adaptation syndrome (SAS), to monitor and record in-flight data from the crew, to determine if prediction criteria for SAS can be established, and, finally, to develop an ambulatory instrument package to mount the crew throughout the mission. The purpose of the Ambulatory Feedback System (AFS) is to record the responses of the subject during a provocative event in space and provide a real-time feedback display to reinforce the training.
NASA Technical Reports Server (NTRS)
Sevart, F. D.; Patel, S. M.
1973-01-01
Testing and evaluation of a stability augmentation system for aircraft flight control were performed. The flutter suppression system and synthesis conducted on a scale model of a supersonic wing for a transport aircraft are discussed. Mechanization and testing of the leading and trailing edge surface actuation systems are described. The ride control system analyses for a 375,000 pound gross weight B-52E aircraft are presented. Analyses of the B-52E aircraft maneuver load control system are included.
Liu, Miao; Yang, Shourui; Wang, Zhangying; Huang, Shujun; Liu, Yue; Niu, Zhenqi; Zhang, Xiaoxuan; Zhu, Jigui; Zhang, Zonghua
2016-05-30
Augmented reality system can be applied to provide precise guidance for various kinds of manual works. The adaptability and guiding accuracy of such systems are decided by the computational model and the corresponding calibration method. In this paper, a novel type of augmented reality guiding system and the corresponding designing scheme are proposed. Guided by external positioning equipment, the proposed system can achieve high relative indication accuracy in a large working space. Meanwhile, the proposed system is realized with a digital projector and the general back projection model is derived with geometry relationship between digitized 3D model and the projector in free space. The corresponding calibration method is also designed for the proposed system to obtain the parameters of projector. To validate the proposed back projection model, the coordinate data collected by a 3D positioning equipment is used to calculate and optimize the extrinsic parameters. The final projecting indication accuracy of the system is verified with subpixel pattern projecting technique.
TDRSS Augmentation System for Satellites
NASA Technical Reports Server (NTRS)
Heckler, Gregory W.; Gramling, Cheryl; Valdez, Jennifer; Baldwin, Philip
2016-01-01
In 2015, NASA Goddard Space Flight Center (GSFC) reinvigorated the development of the TDRSS Augmentation Service for Satellites (TASS). TASS is a global, space-based, communications and navigation service for users of Global Navigation Satellite Systems(GNSS) and the Tracking and Data Relay Satellite System (TDRSS). TASS leverages the existing TDRSS to provide an S-band beacon radio navigation and messaging source to users at orbital altitudes 1400 km and below.
NASA Technical Reports Server (NTRS)
1983-01-01
The engineering and fabrication of the test ACT system, produced in the third program element of the IAAC Project is documented. The system incorporates pitch-augmented stability and wing-load alleviation, plus full authority fly-by-wire control of the elevators. The pitch-augmented stability is designed to have reliability sufficient to allow flight with neutral or negative inherent longitudinal stability.
ERIC Educational Resources Information Center
Hsu, Wen-Chun; Shih, Ju-Ling
2016-01-01
In this study, to learn the routine of Tantui, a branch of martial arts was taken as an object of research. Fitts' stages of motor learning and augmented reality (AR) were applied to a 3D mobile-assisted learning system for martial arts, which was characterized by free viewing angles. With the new system, learners could rotate the viewing angle of…
Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment
López-Mir, F.; Naranjo, V.; Fuertes, J. J.; Alcañiz, M.; Bueno, J.; Pareja, E.
2013-01-01
Purpose. This work presents the protocol carried out in the development and validation of an augmented reality system which was installed in an operating theatre to help surgeons with trocar placement during laparoscopic surgery. The purpose of this validation is to demonstrate the improvements that this system can provide to the field of medicine, particularly surgery. Method. Two experiments that were noninvasive for both the patient and the surgeon were designed. In one of these experiments the augmented reality system was used, the other one was the control experiment, and the system was not used. The type of operation selected for all cases was a cholecystectomy due to the low degree of complexity and complications before, during, and after the surgery. The technique used in the placement of trocars was the French technique, but the results can be extrapolated to any other technique and operation. Results and Conclusion. Four clinicians and ninety-six measurements obtained of twenty-four patients (randomly assigned in each experiment) were involved in these experiments. The final results show an improvement in accuracy and variability of 33% and 63%, respectively, in comparison to traditional methods, demonstrating that the use of an augmented reality system offers advantages for trocar placement in laparoscopic surgery. PMID:24236293
Flashback Detection Sensor for Hydrogen Augmented Natural Gas Combustion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, J.D.; Chorpening, B.T.; Sidwell, T.
2007-05-01
The use of hydrogen augmented fuel is being investigated by various researchers as a method to extend the lean operating limit, and potentially reduce thermal NOx formation in natural gas fired lean premixed (LPM) combustion systems. The resulting increase in flame speed during hydrogen augmentation, however, increases the propensity for flashback in LPM systems. Real-time in-situ monitoring of flashback is important for the development of control strategies for use of hydrogen augmented fuel in state-of-the-art combustion systems, and for the development of advanced hydrogen combustion systems. The National Energy Technology Laboratory (NETL) and Woodward Industrial Controls are developing a combustionmore » control and diagnostics sensor (CCADS), which has already been demonstrated as a useful sensor for in-situ monitoring of natural gas combustion, including detection of important combustion events such as flashback and lean blowoff. Since CCADS is a flame ionization sensor technique, the low ion concentration produced in pure hydrogen combustion raises concerns of whether CCADS can be used to monitor flashback in hydrogen augmented combustion. This paper discusses CCADS tests conducted at 0.2-0.6 MPa (2-6 atm), demonstrating flashback detection with fuel compositions up to 80% hydrogen (by volume) mixed with natural gas. NETL’s Simulation Validation (SimVal) combustor offers full optical access to pressurized combustion during these tests. The CCADS data and high-speed video show the reaction zone moves upstream into the nozzle as the hydrogen fuel concentration increases, as is expected with the increased flame speed of the mixture. The CCADS data and video also demonstrate the opportunity for using CCADS to provide the necessary in-situ monitor to control flashback and lean blowoff in hydrogen augmented combustion applications.« less
Usability Evaluation of an Augmented Reality System for Teaching Euclidean Vectors
ERIC Educational Resources Information Center
Martin-Gonzalez, Anabel; Chi-Poot, Angel; Uc-Cetina, Victor
2016-01-01
Augmented reality (AR) is one of the emerging technologies that has demonstrated to be an efficient technological tool to enhance learning techniques. In this paper, we describe the development and evaluation of an AR system for teaching Euclidean vectors in physics and mathematics. The goal of this pedagogical tool is to facilitate user's…
A Mobile Augmented Reality System for the Learning of Dental Morphology
ERIC Educational Resources Information Center
Juan, M.-Carmen; Alexandrescu, Lucian; Folguera, Fernando; García-García, Inmaculada
2016-01-01
Three-dimensional models are important when the learning content is difficult to acquire from 2D images or other traditional methods. This is the case for learning dental morphology. In this paper, we present a mobile augmented reality (AR) system for learning dental morphology. A study with students was carried out to determine whether learning…
ERIC Educational Resources Information Center
Crowe, Dale; LaPierre, Martin; Kebritchi, Mansureh
2017-01-01
With augmented intelligence/knowledge based system (KBS) it is now possible to develop distance learning applications to support both curriculum and administrative tasks. Instructional designers and information technology (IT) professionals are now moving from the programmable systems era that started in the 1950s to the cognitive computing era.…
NASA Technical Reports Server (NTRS)
Feather, J. B.; Joshi, D. S.
1981-01-01
Handling qualities of the unaugmented advanced supersonic transport (AST) are deficient in the low-speed, landing approach regime. Consequently, improvement in handling with active control augmentation systems has been achieved using implicit model-following techniques. Extensive fixed-based simulator evaluations were used to validate these systems prior to tests with full motion and visual capabilities on a six-axis motion-base simulator (MBS). These tests compared the handling qualities of the unaugmented AST with several augmented configurations to ascertain the effectiveness of these systems. Cooper-Harper ratings, tracking errors, and control activity data from the MBS tests have been analyzed statistically. The results show the fully augmented AST handling qualities have been improved to an acceptable level.
Krause, Margaret B
2015-11-01
The aim of this review is to provide a background on the neurocognitive aspects of the reading process and review neuroscientific studies of individuals with developmental dyslexia, which provide evidence for amodal processing deficits. Hari, Renvall, and Tanskanen (2001) propose amodal sluggish attentional shifting (SAS) as a causal factor for temporal processing deficits in dyslexia. Undergirding this theory is the notion that when dyslexics are faced with rapid sequences of stimuli, their automatic attentional systems fail to disengage efficiently, which leads to difficulty when moving from one item to the next (Lallier et al., ). This results in atypical perception of rapid stimulus sequences. Until recently, the SAS theory, particularly the examination of amodal attentional deficits, was studied solely through the use of behavioural measures (Facoetti et al., ; Facoetti, Lorusso, Cattaneo, Galli, & Molteni, ). This paper examines evidence within the literature that provides a basis for further exploration of amodal SAS as an underlying deficit in developmental dyslexia. Copyright © 2015 John Wiley & Sons, Ltd.
Applied Augmented Reality for High Precision Maintenance
NASA Astrophysics Data System (ADS)
Dever, Clark
Augmented Reality had a major consumer breakthrough this year with Pokemon Go. The underlying technologies that made that app a success with gamers can be applied to improve the efficiency and efficacy of workers. This session will explore some of the use cases for augmented reality in an industrial environment. In doing so, the environmental impacts and human factors that must be considered will be explored. Additionally, the sensors, algorithms, and visualization techniques used to realize augmented reality will be discussed. The benefits of augmented reality solutions in industrial environments include automated data recording, improved quality assurance, reduction in training costs and improved mean-time-to-resolution. As technology continues to follow Moore's law, more applications will become feasible as performance-per-dollar increases across all system components.
Avoiding Focus Shifts in Surgical Telementoring Using an Augmented Reality Transparent Display.
Andersen, Daniel; Popescu, Voicu; Cabrera, Maria Eugenia; Shanghavi, Aditya; Gomez, Gerardo; Marley, Sherri; Mullis, Brian; Wachs, Juan
2016-01-01
Conventional surgical telementoring systems require the trainee to shift focus away from the operating field to a nearby monitor to receive mentor guidance. This paper presents the next generation of telementoring systems. Our system, STAR (System for Telementoring with Augmented Reality) avoids focus shifts by placing mentor annotations directly into the trainee's field of view using augmented reality transparent display technology. This prototype was tested with pre-medical and medical students. Experiments were conducted where participants were asked to identify precise operating field locations communicated to them using either STAR or a conventional telementoring system. STAR was shown to improve accuracy and to reduce focus shifts. The initial STAR prototype only provides an approximate transparent display effect, without visual continuity between the display and the surrounding area. The current version of our transparent display provides visual continuity by showing the geometry and color of the operating field from the trainee's viewpoint.
Wearable computer for mobile augmented-reality-based controlling of an intelligent robot
NASA Astrophysics Data System (ADS)
Turunen, Tuukka; Roening, Juha; Ahola, Sami; Pyssysalo, Tino
2000-10-01
An intelligent robot can be utilized to perform tasks that are either hazardous or unpleasant for humans. Such tasks include working in disaster areas or conditions that are, for example, too hot. An intelligent robot can work on its own to some extent, but in some cases the aid of humans will be needed. This requires means for controlling the robot from somewhere else, i.e. teleoperation. Mobile augmented reality can be utilized as a user interface to the environment, as it enhances the user's perception of the situation compared to other interfacing methods and allows the user to perform other tasks while controlling the intelligent robot. Augmented reality is a method that combines virtual objects into the user's perception of the real world. As computer technology evolves, it is possible to build very small devices that have sufficient capabilities for augmented reality applications. We have evaluated the existing wearable computers and mobile augmented reality systems to build a prototype of a future mobile terminal- the CyPhone. A wearable computer with sufficient system resources for applications, wireless communication media with sufficient throughput and enough interfaces for peripherals has been built at the University of Oulu. It is self-sustained in energy, with enough operating time for the applications to be useful, and uses accurate positioning systems.
Voncken, M J; Dijk, K F L
2013-02-01
Socially anxious individuals (SAs) not only fear social rejection, accumulating studies show that SAs are indeed judged as less likeable after social interaction with others. This study investigates if SAs already make a more negative impression on others in the very first seconds of contact. The study further investigates the development of likeability and the role of self-disclosure herein in two sequential social interactions: first after an unstructured waiting room situation and next after a 'getting acquainted' conversation. Results showed that high SAs (n = 24) elicited a more negative first impression than low SAs (n = 22). Also, although high SAs improved from the first to the second task, they were rated as less likeable after both interactions. The level of self-disclosure behaviour was the strongest predictor for the development of likeability during the sequential social tasks. The absence of an interaction between group and self-disclosure in predicting the development of likeability suggests that this is true for both groups. Thus, high SAs can improve their negative first impression if they are able to increase their self-disclosure behaviour. However, SAs showed a decreased level of self-disclosure behaviour during both social interactions. Targeting self-disclosure behaviour may improve the negative impression SAs elicit in others.
Monitoring Aquifer Depletion from Space: Case Studies from the Saharan and Arabian Aquifers
NASA Astrophysics Data System (ADS)
Ahmed, M.; Sultan, M.; Wahr, J. M.; Yan, E.
2013-12-01
Access to potable fresh water resources is a human right and a basic requirement for economic development in any society. In arid and semi-arid areas, the characterization and understanding of the geologic and hydrologic settings of, and the controlling factors affecting, these resources is gaining increasing importance due to the challenges posed by increasing population. In these areas, there is immense natural fossil fresh water resources stored in large extensive aquifers, the transboundary aquifers. Yet, natural phenomena (e.g., rainfall patterns and climate change) together with human-related factors (e.g., population growth, unsustainable over-exploitation, and pollution) are threatening the sustainability of these resources. In this study, we are developing and applying an integrated cost-effective approach to investigate the nature (i.e., natural and anthropogenic) and the controlling factors affecting the hydrologic settings of the Saharan (i.e., Nubian Sandstone Aquifer System [NSAS], Northwest Sahara Aquifer System [NWSA]) and Arabian (i.e., Arabian Peninsula Aquifer System [APAS]) aquifer systems. Analysis of the Gravity Recovery and Climate Experiment (GRACE)-derived Terrestrial Water Storage (TWS) inter-annual trends over the NSAS and the APAS revealed two areas of significant TWS depletions; the first correlated with the Dakhla Aquifer System (DAS) in the NSAS and second with the Saq Aquifer System (SAS) in the APAS. Annual depletion rates were estimated at 1.3 × 0.66 × 109 m3/yr and 6.95 × 0.68 × 109 m3/yr for DAS and SAS, respectively. Findings include (1) excessive groundwater extraction, not climatic changes, is responsible for the observed TWS depletions ;(2) the DAS could be consumed in 350 years if extraction rates continue to double every 50 years and the APAS available reserves could be consumed within 60-140 years at present extraction (7.08 × 109 m3/yr) and depletion rates; and (3) observed depletions over DAS and SAS and their absence across the remaining segments of the NSAS and the APAS suggest the aquifers are at near-steady conditions except for the DAS and SAS that are witnessing unsteady transient conditions. Implications for applying the methodologies advocated for assessment and optimum management of a large suite of fossil aquifers worldwide are clear.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perkins, Stephen J.; Wright, David W.; Zhang, Hailiang
2016-10-14
The capabilities of current computer simulations provide a unique opportunity to model small-angle scattering (SAS) data at the atomistic level, and to include other structural constraints ranging from molecular and atomistic energetics to crystallography, electron microscopy and NMR. This extends the capabilities of solution scattering and provides deeper insights into the physics and chemistry of the systems studied. Realizing this potential, however, requires integrating the experimental data with a new generation of modelling software. To achieve this, the CCP-SAS collaboration (http://www.ccpsas.org/) is developing open-source, high-throughput and user-friendly software for the atomistic and coarse-grained molecular modelling of scattering data. Robust state-of-the-artmore » molecular simulation engines and molecular dynamics and Monte Carlo force fields provide constraints to the solution structure inferred from the small-angle scattering data, which incorporates the known physical chemistry of the system. The implementation of this software suite involves a tiered approach in whichGenAppprovides the deployment infrastructure for running applications on both standard and high-performance computing hardware, andSASSIEprovides a workflow framework into which modules can be plugged to prepare structures, carry out simulations, calculate theoretical scattering data and compare results with experimental data.GenAppproduces the accessible web-based front end termedSASSIE-web, andGenAppandSASSIEalso make community SAS codes available. Applications are illustrated by case studies: (i) inter-domain flexibility in two- to six-domain proteins as exemplified by HIV-1 Gag, MASP and ubiquitin; (ii) the hinge conformation in human IgG2 and IgA1 antibodies; (iii) the complex formed between a hexameric protein Hfq and mRNA; and (iv) synthetic `bottlebrush' polymers.« less
Brookes, Emre; Rocco, Mattia
2018-03-28
The UltraScan SOlution MOdeller (US-SOMO) is a comprehensive, public domain, open-source suite of computer programs centred on hydrodynamic modelling and small-angle scattering (SAS) data analysis and simulation. We describe here the advances that have been implemented since its last official release (#3087, 2017), which are available from release #3141 for Windows, Linux and Mac operating systems. A major effort has been the transition from the legacy Qt3 cross platform software development and user interface library to the modern Qt5 release. Apart from improved graphical support, this has allowed the direct implementation of the newest, almost two-orders of magnitude faster version of the ZENO hydrodynamic computation algorithm for all operating systems. Coupled with the SoMo-generated bead models with overlaps, ZENO provides the most accurate translational friction computations from atomic-level structures available (Rocco and Byron Eur Biophys J 44:417-431, 2015a), with computational times comparable with or faster than those of other methods. In addition, it has allowed us to introduce the direct representation of each atom in a structure as a (hydrated) bead, opening interesting new modelling possibilities. In the small-angle scattering (SAS) part of the suite, an indirect Fourier transform Bayesian algorithm has been implemented for the computation of the pairwise distance distribution function from SAS data. Finally, the SAS HPLC module, recently upgraded with improved baseline correction and Gaussian decomposition of not baseline-resolved peaks and with advanced statistical evaluation tools (Brookes et al. J Appl Cryst 49:1827-1841, 2016), now allows automatic top-peak frame selection and averaging.
Gu, Liqiang; Hou, Pengyi; Zhang, Ruowen; Liu, Ziying; Bi, Kaishun; Chen, Xiaohui
2016-10-15
A Previous metabolomics study has demonstrated that tyrosine metabolism might be disrupted by treating with Semen Strychni on the cell nephrotoxicity model. To investigate the relationship between Semen Strychni alkaloids (SAs) and endogenous tyrosine, tyramine under the nephrotoxicity condition, an HILIC-ESI-MS/MS based analytical strategy was applied in this study. Based on the established Semen Strychni nephrotoxicity cell model, strychnine and brucine were identified and screened as the main SAs by an HPLC-Q Exactive hybrid quadrupole Orbitrap mass system. Then, a sensitive HILIC-ESI-MS/MS method was developed to simultaneously monitor strychnine, brucine, tyrosine and tyramine in cell lysate. The analytes were separated by a Shiseido CAPCELL CORE PC (150mm×2.1mm, 2.7μm) HILIC column in an acetonitrile/0.1% formic acid gradient system. All the calibration curves were linear with regression coefficients above 0.9924. The absolute recoveries were more than 80.5% and the matrix effects were between 91.6%-107.0%. With the developed method, analytes were successfully determined in cell lysates. Decreased levels of tyrosine and tyramine were observed only in combination with increased levels of SAs, indicating that the disturbance of tyrosine metabolism might be induced by the accumulation of SAs in kidney cell after exposure of Semen Strychni. The HILIC-ESI-MS/MS based analytical strategy is a useful tool to reveal the relationships between the toxic herb components and the endogenous metabolite profiling in the toxicity investigation of herb medicines. Copyright © 2016 Elsevier B.V. All rights reserved.
Perkins, Stephen J; Wright, David W; Zhang, Hailiang; Brookes, Emre H; Chen, Jianhan; Irving, Thomas C; Krueger, Susan; Barlow, David J; Edler, Karen J; Scott, David J; Terrill, Nicholas J; King, Stephen M; Butler, Paul D; Curtis, Joseph E
2016-12-01
The capabilities of current computer simulations provide a unique opportunity to model small-angle scattering (SAS) data at the atomistic level, and to include other structural constraints ranging from molecular and atomistic energetics to crystallography, electron microscopy and NMR. This extends the capabilities of solution scattering and provides deeper insights into the physics and chemistry of the systems studied. Realizing this potential, however, requires integrating the experimental data with a new generation of modelling software. To achieve this, the CCP-SAS collaboration (http://www.ccpsas.org/) is developing open-source, high-throughput and user-friendly software for the atomistic and coarse-grained molecular modelling of scattering data. Robust state-of-the-art molecular simulation engines and molecular dynamics and Monte Carlo force fields provide constraints to the solution structure inferred from the small-angle scattering data, which incorporates the known physical chemistry of the system. The implementation of this software suite involves a tiered approach in which GenApp provides the deployment infrastructure for running applications on both standard and high-performance computing hardware, and SASSIE provides a workflow framework into which modules can be plugged to prepare structures, carry out simulations, calculate theoretical scattering data and compare results with experimental data. GenApp produces the accessible web-based front end termed SASSIE-web , and GenApp and SASSIE also make community SAS codes available. Applications are illustrated by case studies: (i) inter-domain flexibility in two- to six-domain proteins as exemplified by HIV-1 Gag, MASP and ubiquitin; (ii) the hinge conformation in human IgG2 and IgA1 antibodies; (iii) the complex formed between a hexameric protein Hfq and mRNA; and (iv) synthetic 'bottlebrush' polymers.
Formation of indomethacin-saccharin cocrystals using supercritical fluid technology.
Padrela, Luis; Rodrigues, Miguel A; Velaga, Sitaram P; Matos, Henrique A; de Azevedo, Edmundo Gomes
2009-08-12
The main objective of the present work is to check the feasibility of supercritical fluid (SCF) technologies in the screening and design of cocrystals (novel crystalline solids). The cocrystal formation tendencies in three different SCF techniques, focusing on distinct supercritical fluid properties - solvent, anti-solvent and atomization enhancer - were investigated. The effect of processing parameters on the cocrystal formation behaviour and particle properties in these techniques was also studied. A recently reported indomethacin-saccharin (IND-SAC) cocrystalline system was our model system. A 1:1 molar ratio of indomethacin (gamma-form) and saccharin was used as a starting material. The SCF techniques employed in the study include the CSS technique (cocrystallization with supercritical solvent), the SAS technique (supercritical anti-solvent), and the AAS technique (atomization and anti-solvent). The resulting cocrystalline phase was identified using differential scanning calorimetry (DSC), powder X-ray diffraction (PXRD), and Fourier transform-Raman (FT-Raman). The particle morphologies and size distributions were determined using scanning electron microscopy (SEM) and aerosizer, respectively. The pure IND-SAC cocrystals were obtained from SAS and AAS processes, whilst partial to no cocrystal formation occurred in the CSS process. However, no remarkable differences were observed in terms of cocrystal formation at different processing conditions in SAS and AAS processes. Particles from CSS processes were agglomerated and large, whilst needle-to-block-shaped and spherical particles were obtained from SAS and AAS processes, respectively. The particle size distribution of these particles was 0.2-5microm. Particulate IND-SAC cocrystals with different morphologies and sizes (nano-to-micron) were produced using supercritical fluid techniques. This work demonstrates the potential of SCF technologies as screening methods for cocrystals with possibilities for particle engineering.
DOT National Transportation Integrated Search
2001-02-01
The Minnesota data system includes the following basic files: Accident data (Accident File, Vehicle File, Occupant File); Roadlog File; Reference Post File; Traffic File; Intersection File; Bridge (Structures) File; and RR Grade Crossing File. For ea...
Rasch Analysis for Psychometric Improvement of Science Attitude Rating Scales
ERIC Educational Resources Information Center
Oon, Pey-Tee; Fan, Xitao
2017-01-01
Students' attitude towards science (SAS) is often a subject of investigation in science education research. Survey of rating scale is commonly used in the study of SAS. The present study illustrates how Rasch analysis can be used to provide psychometric information of SAS rating scales. The analyses were conducted on a 20-item SAS scale used in an…
Kanou, S; Nagaoka, T; Kobayashi, N; Kurahashi, M; Takeda, S; Aoki, T; Tsuji, T; Urano, T; Abe, T; Magatani, K
2013-01-01
A new concept expired gas measurement system used double cold-trap method was developed. The system could detect selectively volatile organic compound (VOC) derived from the human body. The gas chromatography (GC) profiles of healthy volunteer's expired gas collected by our system were analyzed. As a result, 60 VOCs were detected from the healthy volunteer's expired gas. We examined 14 VOCs among them further, which could be converted to the concentration from the GC profiles. The concentration of almost VOCs decreased when the subjects inspired purified air compared with the atmosphere. On the other hand, isoprene was almost the same. It was strongly suggested that these VOCs were derived from the human body because the concentration of these VOCs in the atmosphere were nearly zero. Expired gas of two sleep apnea syndrome (SAS) patients were analyzed as preliminary study. As a result of the study, the concentration of some VOCs contained in the expired gas of the SAS patients showed higher value than a healthy controls.
Augmented Reality Comes to Physics
NASA Astrophysics Data System (ADS)
Buesing, Mark; Cook, Michael
2013-04-01
Augmented reality (AR) is a technology used on computing devices where processor-generated graphics are rendered over real objects to enhance the sensory experience in real time. In other words, what you are really seeing is augmented by the computer. Many AR games already exist for systems such as Kinect and Nintendo 3DS and mobile apps, such as Tagwhat and Star Chart (a must for astronomy class). The yellow line marking first downs in a televised football game2 and the enhanced puck that makes televised hockey easier to follow3 both use augmented reality to do the job.
Dammermann, Alexander; Maddox, Paul S; Desai, Arshad; Oegema, Karen
2008-02-25
Centrioles are surrounded by pericentriolar material (PCM), which is proposed to promote new centriole assembly by concentrating gamma-tubulin. Here, we quantitatively monitor new centriole assembly in living Caenorhabditis elegans embryos, focusing on the conserved components SAS-4 and SAS-6. We show that SAS-4 and SAS-6 are coordinately recruited to the site of new centriole assembly and reach their maximum levels during S phase. Centriolar SAS-6 is subsequently reduced by a mechanism intrinsic to the early assembly pathway that does not require progression into mitosis. Centriolar SAS-4 remains in dynamic equilibrium with the cytoplasmic pool until late prophase, when it is stably incorporated in a step that requires gamma-tubulin and microtubule assembly. These results indicate that gamma-tubulin in the PCM stabilizes the nascent daughter centriole by promoting microtubule addition to its outer wall. Such a mechanism may help restrict new centriole assembly to the vicinity of preexisting parent centrioles that recruit PCM.
Hebert, G. Ann
1974-01-01
Optimal (NH4)2SO4 concentrations were sought for serum fractionation in order to obtain the gamma globulin as free as possible from other serum components while maintaining a reasonable recovery. Various ammonium sulfate concentrations were used to fractionate sera from mice, hamsters, guinea pigs, monkeys, chimpanzees, swine, chicken, and cattle. All precipitates and supernatants were analyzed by electrophoresis to study the effects of various treatments on the composition of these materials. Approximately 75% of all the gamma globulins were recovered when each serum was fractionated with its optimal sulfate concentration. These optimals were determined to be as follows: three precipitations in 35% saturated ammonium sulfate (SAS) for hamster, chimpanzee, swine, and chicken serum; one precipitation in 35% SAS followed by two in 40% SAS for mouse and guinea pig serum; one precipitation in 30% SAS and then two in 40% SAS for monkey serum; and one precipitation in 30% SAS followed by two in 35% SAS for cattle serum. Images PMID:4132689
Logic flowgraph methodology - A tool for modeling embedded systems
NASA Technical Reports Server (NTRS)
Muthukumar, C. T.; Guarro, S. B.; Apostolakis, G. E.
1991-01-01
The logic flowgraph methodology (LFM), a method for modeling hardware in terms of its process parameters, has been extended to form an analytical tool for the analysis of integrated (hardware/software) embedded systems. In the software part of a given embedded system model, timing and the control flow among different software components are modeled by augmenting LFM with modified Petrinet structures. The objective of the use of such an augmented LFM model is to uncover possible errors and the potential for unanticipated software/hardware interactions. This is done by backtracking through the augmented LFM mode according to established procedures which allow the semiautomated construction of fault trees for any chosen state of the embedded system (top event). These fault trees, in turn, produce the possible combinations of lower-level states (events) that may lead to the top event.
NASA Astrophysics Data System (ADS)
Kulikov, G. M.; Plotnikova, S. V.
2017-03-01
The possibility of using the method of sampling surfaces (SaS) for solving the free vibration problem of threedimensional elasticity for metal-ceramic shells is studied. According to this method, in the shell body, an arbitrary number of SaS parallel to its middle surface are selected in order to take displacements of these surfaces as unknowns. The SaS pass through the nodes of a Chebyshev polynomial, which improves the convergence of the SaS method significantly. As a result, the SaS method can be used to obtain analytical solutions of the vibration problem for metal-ceramic plates and cylindrical shells that asymptotically approach the exact solutions of elasticity as the number of SaS tends to infinity.
Robust preview control for a class of uncertain discrete-time systems with time-varying delay.
Li, Li; Liao, Fucheng
2018-02-01
This paper proposes a concept of robust preview tracking control for uncertain discrete-time systems with time-varying delay. Firstly, a model transformation is employed for an uncertain discrete system with time-varying delay. Then, the auxiliary variables related to the system state and input are introduced to derive an augmented error system that includes future information on the reference signal. This leads to the tracking problem being transformed into a regulator problem. Finally, for the augmented error system, a sufficient condition of asymptotic stability is derived and the preview controller design method is proposed based on the scaled small gain theorem and linear matrix inequality (LMI) technique. The method proposed in this paper not only solves the difficulty problem of applying the difference operator to the time-varying matrices but also simplifies the structure of the augmented error system. The numerical simulation example also illustrates the effectiveness of the results presented in the paper. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
Fransson, Boel A; Chen, Chi-Ya; Noyes, Julie A; Ragle, Claude A
2016-11-01
To determine the construct and concurrent validity of instrument motion metrics for laparoscopic skills assessment in virtual reality and augmented reality simulators. Evaluation study. Veterinarian students (novice, n = 14) and veterinarians (experienced, n = 11) with no or variable laparoscopic experience. Participants' minimally invasive surgery (MIS) experience was determined by hospital records of MIS procedures performed in the Teaching Hospital. Basic laparoscopic skills were assessed by 5 tasks using a physical box trainer. Each participant completed 2 tasks for assessments in each type of simulator (virtual reality: bowel handling and cutting; augmented reality: object positioning and a pericardial window model). Motion metrics such as instrument path length, angle or drift, and economy of motion of each simulator were recorded. None of the motion metrics in a virtual reality simulator showed correlation with experience, or to the basic laparoscopic skills score. All metrics in augmented reality were significantly correlated with experience (time, instrument path, and economy of movement), except for the hand dominance metric. The basic laparoscopic skills score was correlated to all performance metrics in augmented reality. The augmented reality motion metrics differed between American College of Veterinary Surgeons diplomates and residents, whereas basic laparoscopic skills score and virtual reality metrics did not. Our results provide construct validity and concurrent validity for motion analysis metrics for an augmented reality system, whereas a virtual reality system was validated only for the time score. © Copyright 2016 by The American College of Veterinary Surgeons.
NASA Technical Reports Server (NTRS)
Dyakonov, Artem A.; Buck, Gregory M.; Decaro, Anthony D.
2009-01-01
The analysis of effects of the reaction control system jet plumes on aftbody heating of Orion entry capsule is presented. The analysis covered hypersonic continuum part of the entry trajectory. Aerothermal environments at flight conditions were evaluated using Langley Aerothermal Upwind Relaxation Algorithm (LAURA) code and Data Parallel Line Relaxation (DPLR) algorithm code. Results show a marked augmentation of aftbody heating due to roll, yaw and aft pitch thrusters. No significant augmentation is expected due to forward pitch thrusters. Of the conditions surveyed the maximum heat rate on the aftshell is expected when firing a pair of roll thrusters at a maximum deceleration condition.
Goldman, D; Kohn, P M; Hunt, R W
1983-08-01
The following measures were obtained from 42 student volunteers: the General and the Disinhibition subscales of the Sensation Seeking Scale (Form IV), the Reducer-Augmenter Scale, and the Absolute Auditory Threshold. General sensation seeking correlated significantly with the Reducer-Augmenter Scale, r(40) = .59, p less than .001, and the Absolute Auditory Threshold, r(40) = .45, p less than .005. Both results proved general across sex. These findings, that high-sensation seekers tend to be reducers and to lack sensitivity to weak stimulation, were interpreted as supporting strength-of-the-nervous-system theory more than the formulation of Zuckerman and his associates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCord, R.A.; Olson, R.J.
1988-01-01
Environmental research and assessment activities at Oak Ridge National Laboratory (ORNL) include the analysis of spatial and temporal patterns of ecosystem response at a landscape scale. Analysis through use of geographic information system (GIS) involves an interaction between the user and thematic data sets frequently expressed as maps. A portion of GIS analysis has a mathematical or statistical aspect, especially for the analysis of temporal patterns. ARC/INFO is an excellent tool for manipulating GIS data and producing the appropriate map graphics. INFO also has some limited ability to produce statistical tabulation. At ORNL we have extended our capabilities by graphicallymore » interfacing ARC/INFO and SAS/GRAPH to provide a combined mapping and statistical graphics environment. With the data management, statistical, and graphics capabilities of SAS added to ARC/INFO, we have expanded the analytical and graphical dimensions of the GIS environment. Pie or bar charts, frequency curves, hydrographs, or scatter plots as produced by SAS can be added to maps from attribute data associated with ARC/INFO coverages. Numerous, small, simplified graphs can also become a source of complex map ''symbols.'' These additions extend the dimensions of GIS graphics to include time, details of the thematic composition, distribution, and interrelationships. 7 refs., 3 figs.« less
Suenaga, Hideyuki; Hoang Tran, Huy; Liao, Hongen; Masamune, Ken; Dohi, Takeyoshi; Hoshi, Kazuto; Mori, Yoshiyuki; Takato, Tsuyoshi
2013-01-01
To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror. Thereafter, a feasibility study was performed on a volunteer. The accuracy of this system was verified on a solid model while simulating bone resection. Positional registration was attained by identifying and tracking the patient/surgical instrument's position. Thus, integral videography images of jawbones, teeth and the surgical tool were superimposed in the correct position. Stereoscopic images viewed from various angles were accurately displayed. Change in the viewing angle did not negatively affect the surgeon's ability to simultaneously observe the three-dimensional images and the patient, without special glasses. The difference in three-dimensional position of each measuring point on the solid model and augmented reality navigation was almost negligible (<1 mm); this indicates that the system was highly accurate. This augmented reality system was highly accurate and effective for surgical navigation and for overlaying a three-dimensional computed tomography image on a patient's surgical area, enabling the surgeon to understand the positional relationship between the preoperative image and the actual surgical site, with the naked eye. PMID:23703710
PETERS, NICK T.; ROHRBACH, JUSTIN A.; ZALEWSKI, BRIAN A.; BYRKETT, COLLEEN M.; VAUGHN, JACK C.
2003-01-01
We have previously described an example of extensively A-to-G edited cDNA derived from adult heads of the fruitfly Drosophila melanogaster. In that study, the source of the predicted antisense RNA pairing strand for template recognition by dADAR editase was not identified, and the biological significance of the observed hyperediting was not known. Here, we address each of these questions. 4f-rnp and sas-10 are closely adjacent X-linked genes located on opposite DNA strands that produce convergent transcripts. We show that developmentally regulated antisense sas-10 readthrough mRNA arises by activation of an upstream promoter P2 during the late embryo stage of fly development. The sas-10 readthrough transcripts pair with 4f-rnp mRNA to form double-stranded molecules, as indicated by A-to-G editing observed in both RNA strands. It would be predicted that perfect RNA duplexes would be targeted for modification/degradation by enzyme pathways that recognize double-stranded RNAs, leading to decline in 4f-rnp mRNA levels, and this is what we observe. The observation using quantitative RT-PCR that sas-10 readthrough and 4f-rnp transcript levels are inversely related suggests a role for the antisense RNA in posttranscriptional regulation of 4f-rnp gene expression during development. Potential molecular mechanisms that could lead to this result are discussed, one of which is targeted transcript degradation via the RNAi pathway. Insofar as the dADAR editase and RNAi pathways are known to be constitutive in this system, it is likely that control of antisense RNA transcription is the rate-limiting factor. The results provide insight into roles of naturally occurring antisense RNAs in regulation of eukaryotic gene expression. PMID:12756328
Florida, Richard; Goodnight, Jim
2005-01-01
A company's most important asset isn't raw materials, transportation systems, or political influence. It's creative capital--simply put, an arsenal of creative thinkers whose ideas can be turned into valuable products and services. Creative employees pioneer new technologies, birth new industries, and power economic growth. If you want your company to succeed, these are the people you entrust it to. But how do you accommodate the complex and chaotic nature of the creative process while increasing efficiency, improving quality, and raising productivity? Most businesses haven't figured this out. A notable exception is SAS Institute, the world's largest privately held software company. SAS makes Fortune's 100 Best Companies to Work For list every year. The company has enjoyed low employee turnover, high customer satisfaction, and 28 straight years of revenue growth. What's the secret to all this success? The authors, an academic and a CEO, approach this question differently, but they've come to the same conclusion: SAS has learned how to harness the creative energies of all its stakeholders, including its customers, software developers, managers, and support staff. Its framework for managing creativity rests on three guiding principles. First, help employees do their best work by keeping them intellectually engaged and by removing distractions. Second, make managers responsible for sparking creativity and eliminate arbitrary distinctions between "suits" and "creatives". And third, engage customers as creative partners so you can deliver superior products. Underlying all three principles is a mandate to foster interaction--not just to collect individuals' ideas. By nurturing relationships among developers, salespeople, and customers, SAS is investing in its future creative capital. Within a management framework like SAS's, creativity and productivity flourish, flexibility and profitability go hand in hand, and work/life balance and hard work aren't mutually exclusive.
Vulnerability of a public supply well in a karstic aquifer to contamination
Katz, B.G.; McBride, W.S.; Hunt, A.G.; Crandall, C.A.; Metz, P.A.; Eberts, S.M.; Berndt, M.P.
2009-01-01
To assess the vulnerability of ground water to contamination in the karstic Upper Floridan aquifer (UFA), age-dating tracers and selected anthropogenic and naturally occurring compounds were analyzed in multiple water samples from a public supply well (PSW) near Tampa, Florida. Samples also were collected from 28 monitoring wells in the UFA and the overlying surficial aquifer system (SAS) and intermediate confining unit located within the contributing recharge area to the PSW. Age tracer and geochemical data from the earlier stage of the study (2003 through 2005) were combined with new data (2006) on concentrations of sulfur hexafluoride (SF6), tritium (3H), and helium-3, which were consistent with binary mixtures of water for the PSW dominated by young water (less than 7 years). Water samples from the SAS also indicated mostly young water (less than 7 years); however, most water samples from monitoring wells in the UFA had lower SF6 and 3H concentrations than the PSW and SAS, indicating mixtures containing high proportions of older water (more than 60 years). Vulnerability of the PSW to contamination was indicated by predominantly young water and elevated nitrate-N and volatile organic compound concentrations that were similar to those in the SAS. Elevated arsenic (As) concentrations (3 to 19 ??g/L) and higher As(V)/As(III) ratios in the PSW than in water from UFA monitoring wells indicate that oxic water from the SAS likely mobilizes As from pyrite in the UFA matrix. Young water found in the PSW also was present in UFA monitoring wells that tap a highly transmissive zone (43- to 53-m depth) in the UFA. ?? 2008 National Ground Water Association.
Vulnerability of a public supply well in a karstic aquifer to contamination.
Katz, B G; McBride, W S; Hunt, A G; Crandall, C A; Metz, P A; Eberts, S M; Berndt, M P
2009-01-01
To assess the vulnerability of ground water to contamination in the karstic Upper Floridan aquifer (UFA), age-dating tracers and selected anthropogenic and naturally occurring compounds were analyzed in multiple water samples from a public supply well (PSW) near Tampa, Florida. Samples also were collected from 28 monitoring wells in the UFA and the overlying surficial aquifer system (SAS) and intermediate confining unit located within the contributing recharge area to the PSW. Age tracer and geochemical data from the earlier stage of the study (2003 through 2005) were combined with new data (2006) on concentrations of sulfur hexafluoride (SF(6)), tritium ((3)H), and helium-3, which were consistent with binary mixtures of water for the PSW dominated by young water (less than 7 years). Water samples from the SAS also indicated mostly young water (less than 7 years); however, most water samples from monitoring wells in the UFA had lower SF(6) and (3)H concentrations than the PSW and SAS, indicating mixtures containing high proportions of older water (more than 60 years). Vulnerability of the PSW to contamination was indicated by predominantly young water and elevated nitrate-N and volatile organic compound concentrations that were similar to those in the SAS. Elevated arsenic (As) concentrations (3 to 19 microg/L) and higher As(V)/As(III) ratios in the PSW than in water from UFA monitoring wells indicate that oxic water from the SAS likely mobilizes As from pyrite in the UFA matrix. Young water found in the PSW also was present in UFA monitoring wells that tap a highly transmissive zone (43- to 53-m depth) in the UFA.
Park, Junsung; Cho, Wonkyung; Cha, Kwang-Ho; Ahn, Junhyun; Han, Kang; Hwang, Sung-Joo
2013-01-30
Telmisartan is a biopharmaceutical classification system (BCS) class II drug that has extremely low water solubility but is freely soluble in highly alkalized solutions. Few organic solvents can dissolve telmisartan. This solubility problem is the main obstacle achieving the desired bioavailability. Because of its unique characteristics, the supercritical anti-solvent (SAS) process was used to BCS class II drug in a variety of ways including micronization, amorphization and solid dispersion. Solid dispersions were prepared using hydroxypropylmethylcellulose/polyvinylpyrrolidone (HPMC/PVP) at 1:0.5, 1:1, and 1:2 weight ratios of drug to polymer, and pure telmisartan was also treated using the SAS process. Processed samples were characterized for morphology, particle size, crystallinity, solubility, dissolution rate and polymorphic stability. After the SAS process, all samples were converted to the amorphous form and were confirmed to be hundreds nm in size. Solubility and dissolution rate were increased compared to the raw material. Solubility tended to increase with increases in the amount of polymer used. However, unlike the solubility results, the dissolution rate decreased with increases in polymer concentration due to gel layer formation of the polymer. Processed pure telmisartan showed the best drug release even though it had lower solubility compared to other solid dispersions; however, because there were no stabilizers in processed pure telmisartan, it recrystallized after 1 month under severe conditions, while the other solid dispersion samples remained amorphous form. We conclude that after controlling the formulation of solid dispersion, the SAS process could be a promising approach for improving the solubility and dissolution rate of telmisartan. Copyright © 2012 Elsevier B.V. All rights reserved.
Effect of bladder augmentation on VP shunt failure rates in spina bifida.
Gonzalez, Dani O; Cooper, Jennifer N; McLeod, Daryl J
2017-12-11
Most patients with spina bifida require ventriculoperitoneal (VP) shunt placement. Some also require bladder augmentation, which may increase the risk of VP shunt malfunction and/or failure. The aim of this study was to assess whether bladder augmentation affects the rate of VP shunt failure in this population. Using the Pediatric Health Information System, we studied patients with spina bifida born between 1992 and 2014 who underwent VP shunt placement. Using conditional logistic regression, we compared age- and hospital-matched patients who did and did not undergo a bladder augmentation to determine their difference in rates of VP shunt failure. There were 4192 patients with spina bifida who underwent both surgical closure and VP shunt placement. Of these, 203 patients with bladder augmentation could be matched to 593 patients without bladder augmentation. VP shunt failure occurred within 2 years in 7.7% of patients, the majority of whom were in the group who underwent bladder augmentation (87%). After adjusting for confounders, undergoing bladder augmentation was independently associated with VP shunt failure (HR: 33.5, 95% CI: 13.15-85.44, p< 0.001). Bladder augmentation appears to be associated with VP shunt failure. Additional studies are necessary to better define this relationship and identify risk-reduction techniques.
Ishikawa, Joji; Hoshide, Satoshi; Eguchi, Kazuo; Ishikawa, Shizukiyo; Pickering, Thomas G; Shimada, Kazuyuki; Kario, Kazuomi
2010-01-01
Objective Patients with sleep apnea syndrome (SAS) have an increased risk of cardiovascular events and frequently show a non-dipper pattern (blunted nocturnal decline <10%) of systolic blood pressure (BP). We investigated neurohumoral activation and risk factors in relation to nocturnal BP dipping pattern and SAS. Methods We conducted sleep polysomnography and ambulatory BP monitoring, and measured high-sensitivity C-reactive protein (hsCRP), tissue-type plasminogen activator inhibitor-1 (PAI-1), and neurohumoral factors in 121 outpatients with suspected SAS, who were classified in 4 groups depending on the presence or absence of dipping/non-dipping and SAS. Results Non-dippers with SAS had higher hsCRP (overall P<0.001), PAI-1 (overall P=0.004), and aldosterone levels (overall P=0.010) than any of the other 3 groups. After adjustment for significant covariates such as age, sex, body mass index, waist circumference, smoking, alcohol drinking, aspirin use, presence of DM, and insulin, non-dippers with SAS still had a higher hsCRP level than non-dippers without SAS (geometric mean: 1.47 vs. 0.37 mg/L, P=0.001). In multiple linear regression analysis controlling for confounding factors that related with SAS, hsCRP was significantly correlated with 3% oxygen desaturation index (P=0.047). PAI-1 was also highest in the non-dippers with SAS, but this was not independent of obesity. PAI-1 was correlated with insulin (r=0.32, P=0.002) and hsCRP levels (r=0.26, P=0.005). Conclusion Non-dipper status was associated with an increased hsCRP in patients who also had SAS, but not in those who did not, and hsCRP was closely affected by the desaturation level. PAI-1 is also increased in non-dippers with SAS, and is related to insulin and hsCRP. PMID:18475156
Leong, Hio Teng; Fu, Siu Ngor
2018-02-21
Reduction of the subacromial space (SAS) during arm elevation may contribute to rotator cuff tendinopathy. The effects of scapular taping on the SAS in athletes with and without RC tendinopathy is unknown. To investigate the immediate effects of scapular taping on the SAS in athletes with and without RC tendinopathy. Randomized-controlled with repeated measures. University laboratory. Forty-three male volleyball players (17 asymptomatic and 26 with RC tendinopathy, mean age = 22.9±3.5 years) participated in the study. Three scapular taping protocols - no taping (control), taping with tension (therapeutic taping) and taping without tension (sham taping). Ultrasound measurements of the SAS with the arm at 0° and 60° of shoulder abduction, and the change in the SAS between 0° and 60° of shoulder abduction (SAS 0°-60° ) were calculated. Athletes with RC tendinopathy demonstrated larger SAS with therapeutic taping at 60° of shoulder abduction (6.9±1.9 mm vs. 5.8±1.7 mm, mean difference = 1.1 mm, 95% CI = -1.80 - -0.39, p=0.002) when compared to the no taping condition. The tendinopathy group also showed less reduction in the SAS with therapeutic taping during SAS 0°-60° (2.0±1.4 mm vs. 2.8±1.4 mm, p=0.023) when compared to the no taping condition. When tape was applied to the scapula in asymptomatic athletes, our results showed a relatively small increase in the SAS with therapeutic taping during arm resting at 0° of abduction when compared to the no taping condition (8.7±0.9 mm vs. 8.3±0.8 mm, mean difference = 0.4 mm, 95% CI = -0.71 - -0.11, p=0.008). Athletes with RC tendinopathy demonstrated less reduction of the SAS with rigid scapular taping during early arm abduction. Such observation was not evidenced in asymptomatic athletes.
ERIC Educational Resources Information Center
Hsiao, Hsien-Sheng; Chang, Cheng-Sian; Lin, Chien-Yu; Wang, Yau-Zng
2016-01-01
This study focused on how to enhance the interactivity and usefulness of augmented reality (AR) by integrating manipulative interactive tools with a real-world environment. A manipulative AR (MAR) system, which included 3D interactive models and manipulative aids, was designed and developed to teach the unit "Understanding Weather" in a…
Ride quality systems for commuter aircraft
NASA Technical Reports Server (NTRS)
Downing, D. R.; Hammond, T. A.; Amin, S. P.
1983-01-01
The state-of-the-art in Active Ride Augmentation, specifically in terms of its feasibility for commuter aircraft applications. A literature survey was done, and the principal results are presented here through discussion of different Ride Quality Augmentation System (RQAS) designs and advances in related technologies. Recommended follow-on research areas are discussed, and a preliminary RQAS configuration for detailed design and development is proposed.
ERIC Educational Resources Information Center
Wang, Hung-Yuan; Duh, Henry Been-Lirn; Li, Nai; Lin, Tzung-Jin; Tsai, Chin-Chung
2014-01-01
The purpose of this study is to investigate and compare students' collaborative inquiry learning behaviors and their behavior patterns in an augmented reality (AR) simulation system and a traditional 2D simulation system. Their inquiry and discussion processes were analyzed by content analysis and lag sequential analysis (LSA). Forty…
DOT National Transportation Integrated Search
1996-06-01
This volume expands on the presentations in the main manual by presenting further discussions and examples. Contents: Appendix A: The Costs of Travel Surveys; Appendix B: Census Data for Travel Surveys; Appendix C: An Example of the Systems Capabilit...
Image-guided laparoscopic surgery in an open MRI operating theater.
Tsutsumi, Norifumi; Tomikawa, Morimasa; Uemura, Munenori; Akahoshi, Tomohiko; Nagao, Yoshihiro; Konishi, Kozo; Ieiri, Satoshi; Hong, Jaesung; Maehara, Yoshihiko; Hashizume, Makoto
2013-06-01
The recent development of open magnetic resonance imaging (MRI) has provided an opportunity for the next stage of image-guided surgical and interventional procedures. The purpose of this study was to evaluate the feasibility of laparoscopic surgery under the pneumoperitoneum with the system of an open MRI operating theater. Five patients underwent laparoscopic surgery with a real-time augmented reality navigation system that we previously developed in a horizontal-type 0.4-T open MRI operating theater. All procedures were performed in an open MRI operating theater. During the operations, the laparoscopic monitor clearly showed the augmented reality models of the intraperitoneal structures, such as the common bile ducts and the urinary bladder, as well as the proper positions of the prosthesis. The navigation frame rate was 8 frames per min. The mean fiducial registration error was 6.88 ± 6.18 mm in navigated cases. We were able to use magnetic resonance-incompatible surgical instruments out of the 5-Gs restriction area, as well as conventional laparoscopic surgery, and we developed a real-time augmented reality navigation system using open MRI. Laparoscopic surgery with our real-time augmented reality navigation system in the open MRI operating theater is a feasible option.
Belanger, M C; Côté, E; Beauchamp, G
2014-01-01
Predicting subaortic stenosis (SAS) in adult Golden Retriever dogs (GRs) by evaluating them as puppies is hampered by the progressive expression of the SAS phenotype in youth. In some children who develop SAS as adults, an abnormal aortoseptal angle (AoSA) precedes development of stenosis. To determine the normal AoSA in young adult GRs using echocardiography; to assess the value of AoSA in GR puppies for predicting development of the SAS phenotype. Forty-eight 2- to 6-month-old GR puppies. Prospective study. Puppies were recruited from clients and breeders. Puppies were evaluated with a physical examination and an echocardiogram, and this evaluation was repeated when they were 12-18-month-old adults. Puppies were classified as unaffected (WNL) or affected (SAS) retroactively, based on their results as adults. In WNL young adult GRs, mean ± SD AoSA was 152.3 ± 6.5°. Mean ± SD AoSA in SAS puppies (144.9 ± 8.6°) was significantly different from mean AoSA in WNL puppies (155.7 ± 8.8°, P < .01). No puppy with AoSA >160° had the SAS phenotype as a young adult; 93% (75.7-99.1%) of puppies with AoSA <145° had the SAS phenotype as young adults. Peak LVOT velocity increased significantly between evaluations (P < .0001) whereas AoSA did not (P = .45). A steep AoSA in GR puppies is associated with the SAS phenotype in young adulthood. Some GR puppies have an abnormal AoSA that persists in young adulthood and is detectable before peak LVOT velocity reaches levels consistent with SAS. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Trewhella, Jill; Hendrickson, Wayne A; Kleywegt, Gerard J; Sali, Andrej; Sato, Mamoru; Schwede, Torsten; Svergun, Dmitri I; Tainer, John A; Westbrook, John; Berman, Helen M
2013-06-04
This report presents the conclusions of the July 12-13, 2012 meeting of the Small-Angle Scattering Task Force of the worldwide Protein Data Bank (wwPDB; Berman et al., 2003) at Rutgers University in New Brunswick, New Jersey. The task force includes experts in small-angle scattering (SAS), crystallography, data archiving, and molecular modeling who met to consider questions regarding the contributions of SAS to modern structural biology. Recognizing there is a rapidly growing community of structural biology researchers acquiring and interpreting SAS data in terms of increasingly sophisticated molecular models, the task force recommends that (1) a global repository is needed that holds standard format X-ray and neutron SAS data that is searchable and freely accessible for download; (2) a standard dictionary is required for definitions of terms for data collection and for managing the SAS data repository; (3) options should be provided for including in the repository SAS-derived shape and atomistic models based on rigid-body refinement against SAS data along with specific information regarding the uniqueness and uncertainty of the model, and the protocol used to obtain it; (4) criteria need to be agreed upon for assessment of the quality of deposited SAS data and the accuracy of SAS-derived models, and the extent to which a given model fits the SAS data; (5) with the increasing diversity of structural biology data and models being generated, archiving options for models derived from diverse data will be required; and (6) thought leaders from the various structural biology disciplines should jointly define what to archive in the PDB and what complementary archives might be needed, taking into account both scientific needs and funding. Copyright © 2013 Elsevier Ltd. All rights reserved.
Adaptive multimodal interaction in mobile augmented reality: A conceptual framework
NASA Astrophysics Data System (ADS)
Abidin, Rimaniza Zainal; Arshad, Haslina; Shukri, Saidatul A'isyah Ahmad
2017-10-01
Recently, Augmented Reality (AR) is an emerging technology in many mobile applications. Mobile AR was defined as a medium for displaying information merged with the real world environment mapped with augmented reality surrounding in a single view. There are four main types of mobile augmented reality interfaces and one of them are multimodal interfaces. Multimodal interface processes two or more combined user input modes (such as speech, pen, touch, manual gesture, gaze, and head and body movements) in a coordinated manner with multimedia system output. In multimodal interface, many frameworks have been proposed to guide the designer to develop a multimodal applications including in augmented reality environment but there has been little work reviewing the framework of adaptive multimodal interface in mobile augmented reality. The main goal of this study is to propose a conceptual framework to illustrate the adaptive multimodal interface in mobile augmented reality. We reviewed several frameworks that have been proposed in the field of multimodal interfaces, adaptive interface and augmented reality. We analyzed the components in the previous frameworks and measure which can be applied in mobile devices. Our framework can be used as a guide for designers and developer to develop a mobile AR application with an adaptive multimodal interfaces.
Recent Development of Augmented Reality in Surgery: A Review
Vávra, P.; Zonča, P.; Ihnát, P.; El-Gendi, A.
2017-01-01
Introduction The development augmented reality devices allow physicians to incorporate data visualization into diagnostic and treatment procedures to improve work efficiency, safety, and cost and to enhance surgical training. However, the awareness of possibilities of augmented reality is generally low. This review evaluates whether augmented reality can presently improve the results of surgical procedures. Methods We performed a review of available literature dating from 2010 to November 2016 by searching PubMed and Scopus using the terms “augmented reality” and “surgery.” Results. The initial search yielded 808 studies. After removing duplicates and including only journal articles, a total of 417 studies were identified. By reading of abstracts, 91 relevant studies were chosen to be included. 11 references were gathered by cross-referencing. A total of 102 studies were included in this review. Conclusions The present literature suggest an increasing interest of surgeons regarding employing augmented reality into surgery leading to improved safety and efficacy of surgical procedures. Many studies showed that the performance of newly devised augmented reality systems is comparable to traditional techniques. However, several problems need to be addressed before augmented reality is implemented into the routine practice. PMID:29065604
Hiendrawan, Stevanus; Veriansyah, Bambang; Widjojokusumo, Edward; Tjandrawinata, Raymond R.
2017-01-01
Simultaneous micronization and purification of DLBS3233 bioactive fraction, a combination of two Indonesian herbals Lagerstroemia speciosa and Cinnamomum burmannii has been successfully performed via supercritical anti-solvent (SAS) technology. The objective of the present study was to investigate the effectiveness of SAS technology to micronize and reduce coumarin content of DLBS3233. The effects of four SAS process parameters, i.e. pressure, temperature, concentration and solution flow rate on particle formation were investigated. In SAS process, DLBS3233 was dissolved in dimethylformamide (DMF) as the liquid solvent. The solution was then pumped through a nozzle into a chamber simultaneously with supercritical carbon dioxide (SC-CO2) which acts as the anti-solvent, resulting in DLBS3233 precipitation. Physicochemical properties of unprocessed DLBS3233 and SAS-processed DLBS3233 particles were analyzed using scanning electron microscopy (SEM) and high pressure liquid chromatography (HPLC). Total polyphenol content (TPC) was also analyzed. Particles with mean particle size ranging from 0.107±0.028 μm to 0.298±0.138 μm were obtained by varying the process parameters. SAS-processed DLBS3233 particles showed no coumarin content in all experiments studied in this work. Results of TPC analysis revealed no significant change in SAS-processed DLBS3233 particles compared to unprocessed DLBS3233. Nano-sized DLBS3233 particles with no coumarin content have been successfully produced using SAS process. This study demonstrates the ability of SAS for processing herbal medicine in single step process. PMID:28516056
Social Anxiety Scale for Adolescents (SAS-A): measuring social anxiety among Finnish adolescents.
Ranta, Klaus; Junttila, Niina; Laakkonen, Eero; Uhmavaara, Anni; La Greca, Annette M; Niemi, Päivi M
2012-08-01
The aim of this study was to investigate symptoms of social anxiety and the psychometric properties of the Social Anxiety Scale for Adolescents (SAS-A) among Finnish adolescents, 13-16 years of age. Study 1 (n = 867) examined the distribution of SAS-A scores according to gender and age, and the internal consistency and factor structure of the SAS-A. In a subsample (n = 563; Study 2) concurrent and discriminant validity of the SAS-A were examined relative to the Social Phobia Inventory and the Beck Depression Inventory. Test-retest stability was examined over a 30-month period by repeated measures every 6 months in another subsample (n = 377; Study 3). Results mostly revealed no gender differences in social anxiety, except that boys reported more general social avoidance and distress than girls. Older adolescents (14-16-year-olds) reported higher social anxiety than younger adolescents (12-13-year-olds). Internal consistency for the SAS-A was acceptable for both genders and for all three SAS-A subscales. Confirmatory factor analysis replicated the original 18-item three-factor structure of the SAS-A, accounting for 61% of the variance between items. Evidence for concurrent and discriminant validity was found. Test-retest stability over 6 months was satisfactory. Results support the reliability and validity of the Finnish adaptation of the SAS-A, and further indicate that gender differences in adolescents' social anxiety may vary across Western countries.
Hashim, Hairul Anuar; Shaharuddin, Saidatin Sabiyah; Hamidan, Shazarina; Grove, J Robert
2017-02-01
This study examined psychometric properties of a Malaysian-language Sport Anxiety Scale-2 (SAS-2) in three separate studies. Study 1 examined the criterion validity and internal consistency of SAS-2 among 119 developmental hockey players. Measures of trait anxiety and mood states along with digit vigilance, choice reaction time, and depth perception tests were administered. Regression analysis revealed that somatic anxiety and concentration disruption were significantly associated with sustained attention. Worry was significantly associated with depth perception but not sustained attention. Pearson correlation coefficients also revealed significant relationships between SAS-2 subscales and negative mood state dimensions. Study 2 examined the convergent and discriminant validity of SAS-2 by correlating it with state anxiety measured by the CSAI-2R. Significant positive relationships were obtained between SAS-2 subscales and somatic and cognitive state anxiety. Conversely, state self-confidence was negatively related to SAS-2 subscales. In addition, significant differences were observed between men and women in somatic anxiety. Study 3 examined the factorial validity of the Malaysian SAS-2 using confirmatory factor analysis in a sample of 539 young athletes. Confirmatory factor analysis results provided strong support for the SAS-2 factor structure. Path loadings exceeding 0.5 indicated convergent validity among the subscales, and low to moderate subscale intercorrelations provided evidence of discriminant validity. Overall, the results supported the criterion and construct validity of this Malaysian-language SAS-2 instrument.
Hiendrawan, Stevanus; Veriansyah, Bambang; Widjojokusumo, Edward; Tjandrawinata, Raymond R
2017-01-01
Simultaneous micronization and purification of DLBS3233 bioactive fraction, a combination of two Indonesian herbals Lagerstroemia speciosa and Cinnamomum burmannii has been successfully performed via supercritical anti-solvent (SAS) technology. The objective of the present study was to investigate the effectiveness of SAS technology to micronize and reduce coumarin content of DLBS3233. The effects of four SAS process parameters, i.e. pressure, temperature, concentration and solution flow rate on particle formation were investigated. In SAS process, DLBS3233 was dissolved in dimethylformamide (DMF) as the liquid solvent. The solution was then pumped through a nozzle into a chamber simultaneously with supercritical carbon dioxide (SC-CO2) which acts as the anti-solvent, resulting in DLBS3233 precipitation. Physicochemical properties of unprocessed DLBS3233 and SAS-processed DLBS3233 particles were analyzed using scanning electron microscopy (SEM) and high pressure liquid chromatography (HPLC). Total polyphenol content (TPC) was also analyzed. Particles with mean particle size ranging from 0.107±0.028 μ m to 0.298±0.138 μ m were obtained by varying the process parameters. SAS-processed DLBS3233 particles showed no coumarin content in all experiments studied in this work. Results of TPC analysis revealed no significant change in SAS-processed DLBS3233 particles compared to unprocessed DLBS3233. Nano-sized DLBS3233 particles with no coumarin content have been successfully produced using SAS process. This study demonstrates the ability of SAS for processing herbal medicine in single step process.
Search for an X-ray identification of a strong gamma-ray source. [sas-3 observations
NASA Technical Reports Server (NTRS)
Lamb, R. C.
1979-01-01
X-rays from Cygnus X-3 were observed during early 1978 with the detectors of the SAS-3 satellite. These observations in conjunction with earlier UHURU and ANS data indicate that the 4.8 hr period of Cygnus X-3 is increasing at the rate of P/P = (5/1 plus or minus 1.3) x 10 to the minus 6 power/1 yr. The sign and magnitude for this change are incompatible with a rotation model for the period and are in reasonable agreement with model predictions for orbital changes associated with mass loss and transfer in a binary system.
NASA Technical Reports Server (NTRS)
Chen, R. T. N.; Talbot, P. D.; Gerdes, R. M.; Dugan, D. C.
1979-01-01
Four basic single-rotor helicopters, one teetering, on articulated, and two hingeless, which were found to have a variety of major deficiencies in a previous fixed-based simulator study, were selected as baseline configurations. The stability and control augmentation systems (SCAS) include simple control augmentation systems to decouple pitch and yaw responses due to collective input and to quicken the pitch and roll control responses; SCAS of rate-command type designed to optimize the sensitivity and damping and to decouple the pitch-roll due to aircraft angular tate; and attitude-command type SCAS. Pilot ratings and commentary are presented as well as performance data related to the task. SCAS control usages and their gain levels associated with specific rotor types are also discussed.
Hands in space: gesture interaction with augmented-reality interfaces.
Billinghurst, Mark; Piumsomboon, Tham; Huidong Bai
2014-01-01
Researchers at the Human Interface Technology Laboratory New Zealand (HIT Lab NZ) are investigating free-hand gestures for natural interaction with augmented-reality interfaces. They've applied the results to systems for desktop computers and mobile devices.
Sleeve reaction chamber system
Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA
2009-08-25
A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.
Wolf, Marc E; Chatzikonstantinou, Anastasios; Grüttner, Joachim; Ebert, Anne D; Walter, Thomas; Hennerici, Michael G; Fatar, Marc
2016-01-01
Acute stroke is a medical emergency with various clinical presentations. Since the introduction of systemic thrombolytic treatment, stroke diagnosis has been made quickly and with great caution, and the trend of rapid presentation at hospitals has increased. In our multidisciplinary Emergency Department, we prospectively collected and analysed data of consecutive patients presenting with suspected acute stroke (SAS) or transient ischemic attack (TIA). Four hundred ten patients (200 men, mean age 68 ± 16, range 17-93 years) with SAS were admitted of which 105 were prehospitally announced as within the time-window for thrombolytic treatment (TW). Diagnosis of acute stroke/TIA was retained in 147 (35.9%). The initially reported TW <4.5 h was wrong in 35.3%. Thrombolysis was performed in 27 patients (23.5% of ischemic stroke patients; 6.6% of all SAS). Diagnosis of another neurologic disease was made in 62 (15.1%). Major differential diagnoses came from the field of internal medicine, psychiatry or otorhinolaryngology. One hundred fifty patients (36.6%) were rapidly discharged. About half the number of our patients admitted for SAS did not suffer from an acute neurologic disease. Residual symptoms post-stroke might be partly responsible for initial misinterpretation. The crucial difference between symptom onset and symptom recognition needs to be emphasized to improve the prehospital assessment of the TW. © 2016 S. Karger AG, Basel.
Hilbert, Manuel; Noga, Akira; Frey, Daniel; Hamel, Virginie; Guichard, Paul; Kraatz, Sebastian H W; Pfreundschuh, Moritz; Hosner, Sarah; Flückiger, Isabelle; Jaussi, Rolf; Wieser, Mara M; Thieltges, Katherine M; Deupi, Xavier; Müller, Daniel J; Kammerer, Richard A; Gönczy, Pierre; Hirono, Masafumi; Steinmetz, Michel O
2016-04-01
Centrioles are critical for the formation of centrosomes, cilia and flagella in eukaryotes. They are thought to assemble around a nine-fold symmetric cartwheel structure established by SAS-6 proteins. Here, we have engineered Chlamydomonas reinhardtii SAS-6-based oligomers with symmetries ranging from five- to ten-fold. Expression of a SAS-6 mutant that forms six-fold symmetric cartwheel structures in vitro resulted in cartwheels and centrioles with eight- or nine-fold symmetries in vivo. In combination with Bld10 mutants that weaken cartwheel-microtubule interactions, this SAS-6 mutant produced six- to eight-fold symmetric cartwheels. Concurrently, the microtubule wall maintained eight- and nine-fold symmetries. Expressing SAS-6 with analogous mutations in human cells resulted in nine-fold symmetric centrioles that exhibited impaired length and organization. Together, our data suggest that the self-assembly properties of SAS-6 instruct cartwheel symmetry, and lead us to propose a model in which the cartwheel and the microtubule wall assemble in an interdependent manner to establish the native architecture of centrioles.
Flight test results for a separate surface stability augmented Beech model 99
NASA Technical Reports Server (NTRS)
Jenks, G. E.; Henry, H. F.; Roskam, J.
1977-01-01
A flight evaluation of a Beech model 99 equipped with an attitude command control system incorporating separate surface stability augmentation (SSSA) was conducted to determine whether an attitude command control system could be implemented using separate surface controls, and to determine whether the handling and ride qualities of the aircraft were improved by the SSSA attitude command system. The results of the program revealed that SSSA is a viable approach to implementing attitude command and also that SSSA has the capability of performing less demanding augmentation tasks such as yaw damping, wing leveling, and pitch damping. The program also revealed that attitude command did improve the pilot rating and ride qualities of the airplane while flying an IFR mission in turbulence. Some disadvantages of the system included the necessity of holding aileron force in a banked turn and excessive stiffness in the pitch axis.
An adaptive brain actuated system for augmenting rehabilitation
Roset, Scott A.; Gant, Katie; Prasad, Abhishek; Sanchez, Justin C.
2014-01-01
For people living with paralysis, restoration of hand function remains the top priority because it leads to independence and improvement in quality of life. In approaches to restore hand and arm function, a goal is to better engage voluntary control and counteract maladaptive brain reorganization that results from non-use. Standard rehabilitation augmented with developments from the study of brain-computer interfaces could provide a combined therapy approach for motor cortex rehabilitation and to alleviate motor impairments. In this paper, an adaptive brain-computer interface system intended for application to control a functional electrical stimulation (FES) device is developed as an experimental test bed for augmenting rehabilitation with a brain-computer interface. The system's performance is improved throughout rehabilitation by passive user feedback and reinforcement learning. By continuously adapting to the user's brain activity, similar adaptive systems could be used to support clinical brain-computer interface neurorehabilitation over multiple days. PMID:25565945
Development and human factors analysis of neuronavigation vs. augmented reality.
Pandya, Abhilash; Siadat, Mohammad-Reza; Auner, Greg; Kalash, Mohammad; Ellis, R Darin
2004-01-01
This paper is focused on the human factors analysis comparing a standard neuronavigation system with an augmented reality system. We use a passive articulated arm (Microscribe, Immersion technology) to track a calibrated end-effector mounted video camera. In real time, we superimpose the live video view with the synchronized graphical view of CT-derived segmented object(s) of interest within a phantom skull. Using the same robotic arm, we have developed a neuronavigation system able to show the end-effector of the arm on orthogonal CT scans. Both the AR and the neuronavigation systems have been shown to be within 3mm of accuracy. A human factors study was conducted in which subjects were asked to draw craniotomies and answer questions to gage their understanding of the phantom objects. The human factors study included 21 subjects and indicated that the subjects performed faster, with more accuracy and less errors using the Augmented Reality interface.
Improved approximations for control augmented structural synthesis
NASA Technical Reports Server (NTRS)
Thomas, H. L.; Schmit, L. A.
1990-01-01
A methodology for control-augmented structural synthesis is presented for structure-control systems which can be modeled as an assemblage of beam, truss, and nonstructural mass elements augmented by a noncollocated direct output feedback control system. Truss areas, beam cross sectional dimensions, nonstructural masses and rotary inertias, and controller position and velocity gains are treated simultaneously as design variables. The structural mass and a control-system performance index can be minimized simultaneously, with design constraints placed on static stresses and displacements, dynamic harmonic displacements and forces, structural frequencies, and closed-loop eigenvalues and damping ratios. Intermediate design-variable and response-quantity concepts are used to generate new approximations for displacements and actuator forces under harmonic dynamic loads and for system complex eigenvalues. This improves the overall efficiency of the procedure by reducing the number of complete analyses required for convergence. Numerical results which illustrate the effectiveness of the method are given.
Safety Arguments for Next Generation, Location Aware Computing
NASA Technical Reports Server (NTRS)
Johnson, C. W.; Holloway, C. M.
2010-01-01
Concerns over accuracy, availability, integrity, and continuity have limited the integration of Global Positioning System (GPS) and Global Navigation Satellite System (GLONASS) for safety-critical applications. More recent augmentation systems, such as the European Geostationary Navigation Overlay Service (EGNOS) and the North American Wide Area Augmentation System (WAAS) have begun to address these concerns. Augmentation architectures build on the existing GPS/GLONASS infrastructures to support location based services in Safety of Life (SoL) applications. Much of the technical development has been directed by air traffic management requirements, in anticipation of the more extensive support to be offered by GPS III and Galileo. WAAS has already been approved to provide vertical guidance for aviation applications. During the next twelve months, the full certification of EGNOS for SoL applications is expected. This paper discusses similarities and differences between the safety assessment techniques used in Europe and North America.
During the summer of 2002, phytoplankton chlorophyll concentrations were determined in Narragansett Bay, Rhode Island using a light aircraft equipped with the MicroSAS remote sensing system. From an altitude of 300 m, the three sensor system measured sea surface radiance (Lt), sk...
Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei
2016-01-01
Objective To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. Materials and Methods In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. Results The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. Conclusion The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon’s skills and knowledge, not as a substitute. PMID:26757365
Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei
2016-01-01
To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon's skills and knowledge, not as a substitute.
Augmentative Communication Services in the Schools.
ERIC Educational Resources Information Center
Blackstone, Sarah W.
1989-01-01
The article considers current issues concerning service delivery systems and practices concerning augmentative and alternative communication (AAC) services in U.S. schools. Concerns in AAC program development are noted and service delivery models (center-based, community-based, or collaborative) are compared. (DB)
Monterey-Salinas Transit ITS Augmentation Project : Phase III Evaluation Report
DOT National Transportation Integrated Search
2009-12-01
The purpose of this document is to present the findings from Phase II and Phase III of the Evaluation of the Intelligent Transportation Systems (ITS) Augmentation Project that was implemented at the Monterey-Salinas Transit (MST) in Monterey, Califor...
NASA Technical Reports Server (NTRS)
Nissim, E. (Inventor)
1973-01-01
An active aerodynamic control system to control flutter over a large range of oscillatory frequencies is described. The system is not affected by mass, stiffness, elastic axis, or center of gravity location of the system, mode of vibration, or Mach number. The system consists of one or more pairs of leading edge and trailing edge hinged or deformable control surfaces, each pair operated in concert by a stability augmentation system. Torsion and bending motions are sensed and converted by the stability augmentation system into leading and trailing edge control surface deflections which produce lift forces and pitching moments to suppress flutter.
ERIC Educational Resources Information Center
Chiang, Tosti H. C.; Yang, Stephen J. H.; Hwang, Gwo-Jen
2014-01-01
In this study, an augmented reality-based mobile learning system is proposed for conducting inquiry-based learning activities. An experiment has been conducted to examine the effectiveness of the proposed approach in terms of learning achievements and motivations. The subjects were 57 fourth graders from two classes taught by the same teacher in…
ERIC Educational Resources Information Center
Mayer, John; Kieras, David E.
Using a system based on standard augmented transition network (ATN) parsing approach, this report describes a technique for the rapid development of natural language parsing, called High-Level Grammar Specification Language (HGSL). The first part of the report describes the syntax and semantics of HGSL and the network implementation of each of its…
Use of NTRIP for optimizing the decoding algorithm for real-time data streams.
He, Zhanke; Tang, Wenda; Yang, Xuhai; Wang, Liming; Liu, Jihua
2014-10-10
As a network transmission protocol, Networked Transport of RTCM via Internet Protocol (NTRIP) is widely used in GPS and Global Orbiting Navigational Satellite System (GLONASS) Augmentation systems, such as Continuous Operational Reference System (CORS), Wide Area Augmentation System (WAAS) and Satellite Based Augmentation Systems (SBAS). With the deployment of BeiDou Navigation Satellite system(BDS) to serve the Asia-Pacific region, there are increasing needs for ground monitoring of the BeiDou Navigation Satellite system and the development of the high-precision real-time BeiDou products. This paper aims to optimize the decoding algorithm of NTRIP Client data streams and the user authentication strategies of the NTRIP Caster based on NTRIP. The proposed method greatly enhances the handling efficiency and significantly reduces the data transmission delay compared with the Federal Agency for Cartography and Geodesy (BKG) NTRIP. Meanwhile, a transcoding method is proposed to facilitate the data transformation from the BINary EXchange (BINEX) format to the RTCM format. The transformation scheme thus solves the problem of handing real-time data streams from Trimble receivers in the BeiDou Navigation Satellite System indigenously developed by China.
[Hypertrophic adipose tissue transplantation secondary to a lipopenisculpture].
Moullot, P; Nguyen, P-S; Philandrianos, C; Casanova, D
2014-10-01
Reconstruction of the penile skin requires a functional and esthetically perfect result, combining a high degree of skin elasticity to allow regular erections and a satisfactory cosmetic appearance. Demand for cosmetic surgery penile augmentation continues to increase for several years. The surgical technique most commonly used is now widening and lengthening lipopenisculpture (LPS), combining an adipocyte graft to a section of the suspensory ligament of the penis. A patient who underwent LPS presented several years after a major hypertrophy of the adipocyte graft, making it impossible to have sexual activities, imposing to perform liposuction. This liposuction was being complicated by necrosis of the penile skin. Reconstruction was required and consisted of an unexpanded thin skin graft associated with artificial dermis. Through technical adaptation of the skin graft on the erect penis, the use of artificial dermis and external stabilization by negative pressure therapy, reconstruction of the penile skin provides excellent aesthetic and functional results. Finally, it is rarely reported in the literature complications of lipofilling like alteration of the aesthetic result after weight gain. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Jakovetic, Dusan; Xavier, João; Moura, José M. F.
2011-08-01
We study distributed optimization in networked systems, where nodes cooperate to find the optimal quantity of common interest, x=x^\\star. The objective function of the corresponding optimization problem is the sum of private (known only by a node,) convex, nodes' objectives and each node imposes a private convex constraint on the allowed values of x. We solve this problem for generic connected network topologies with asymmetric random link failures with a novel distributed, decentralized algorithm. We refer to this algorithm as AL-G (augmented Lagrangian gossiping,) and to its variants as AL-MG (augmented Lagrangian multi neighbor gossiping) and AL-BG (augmented Lagrangian broadcast gossiping.) The AL-G algorithm is based on the augmented Lagrangian dual function. Dual variables are updated by the standard method of multipliers, at a slow time scale. To update the primal variables, we propose a novel, Gauss-Seidel type, randomized algorithm, at a fast time scale. AL-G uses unidirectional gossip communication, only between immediate neighbors in the network and is resilient to random link failures. For networks with reliable communication (i.e., no failures,) the simplified, AL-BG (augmented Lagrangian broadcast gossiping) algorithm reduces communication, computation and data storage cost. We prove convergence for all proposed algorithms and demonstrate by simulations the effectiveness on two applications: l_1-regularized logistic regression for classification and cooperative spectrum sensing for cognitive radio networks.
NASA Astrophysics Data System (ADS)
Tu, Rui; Zhang, Rui; Zhang, Pengfei; Liu, Jinhai; Lu, Xiaochun
2018-07-01
This study proposes an approach to facilitate real-time fast point positioning of the BeiDou Navigation Satellite System (BDS) based on regional augmentation information. We term this as the precise positioning based on augmentation information (BPP) approach. The coordinates of the reference stations were highly constrained to extract the augmentation information, which contained not only the satellite orbit clock error correlated with the satellite running state, but also included the atmosphere error and unmodeled error, which are correlated with the spatial and temporal states. Based on these mixed augmentation corrections, a precise point positioning (PPP) model could be used for the coordinates estimation of the user stations, and the float ambiguity could be easily fixed for the single-difference between satellites. Thus, this technique provided a quick and high-precision positioning service. Three different datasets with small, medium, and large baselines (0.6 km, 30 km and 136 km) were used to validate the feasibility and effectiveness of the proposed BPP method. The validations showed that using the BPP model, 1–2 cm positioning service can be provided in a 100 km wide area after just 2 s of initialization. Thus, as the proposed approach not only capitalized on both PPP and RTK but also provided consistent application, it can be used for area augmentation positioning.
Kramers, Matthew; Armstrong, Ryan; Bakhshmand, Saeed M; Fenster, Aaron; de Ribaupierre, Sandrine; Eagleson, Roy
2014-01-01
Image guidance can provide surgeons with valuable contextual information during a medical intervention. Often, image guidance systems require considerable infrastructure, setup-time, and operator experience to be utilized. Certain procedures performed at bedside are susceptible to navigational errors that can lead to complications. We present an application for mobile devices that can provide image guidance using augmented reality to assist in performing neurosurgical tasks. A methodology is outlined that evaluates this mode of visualization from the standpoint of perceptual localization, depth estimation, and pointing performance, in scenarios derived from a neurosurgical targeting task. By measuring user variability and speed we can report objective metrics of performance for our augmented reality guidance system.
Quantification of intraventricular blood clot in MR-guided focused ultrasound surgery
NASA Astrophysics Data System (ADS)
Hess, Maggie; Looi, Thomas; Lasso, Andras; Fichtinger, Gabor; Drake, James
2015-03-01
Intraventricular hemorrhage (IVH) affects nearly 15% of preterm infants. It can lead to ventricular dilation and cognitive impairment. To ablate IVH clots, MR-guided focused ultrasound surgery (MRgFUS) is investigated. This procedure requires accurate, fast and consistent quantification of ventricle and clot volumes. We developed a semi-autonomous segmentation (SAS) algorithm for measuring changes in the ventricle and clot volumes. Images are normalized, and then ventricle and clot masks are registered to the images. Voxels of the registered masks and voxels obtained by thresholding the normalized images are used as seed points for competitive region growing, which provides the final segmentation. The user selects the areas of interest for correspondence after thresholding and these selections are the final seeds for region growing. SAS was evaluated on an IVH porcine model. SAS was compared to ground truth manual segmentation (MS) for accuracy, efficiency, and consistency. Accuracy was determined by comparing clot and ventricle volumes produced by SAS and MS, and comparing contours by calculating 95% Hausdorff distances between the two labels. In Two-One-Sided Test, SAS and MS were found to be significantly equivalent (p < 0.01). SAS on average was found to be 15 times faster than MS (p < 0.01). Consistency was determined by repeated segmentation of the same image by both SAS and manual methods, SAS being significantly more consistent than MS (p < 0.05). SAS is a viable method to quantify the IVH clot and the lateral brain ventricles and it is serving in a large-scale porcine study of MRgFUS treatment of IVH clot lysis.
Ting, Miriam; Rice, Jeremy G; Braid, Stanton M; Lee, Cameron Y S; Suzuki, Jon B
2017-06-01
The objective of this systemic review was to perform a comprehensive overview of systematic reviews and meta-analyses of the maxillary sinus augmentation procedure for implant rehabilitation in humans. The following were evaluated in this overview: (1) anatomic variables affecting sinus augmentation, (2) histomorphometric analysis of the grafted sinus, (3) volumetric changes after sinus grafting, and (4) implant survival beyond 1 year. Electronic databases were searched for systematic reviews and meta-analyses of implant-related sinus augmentation published from 1976 to September 2015. The studies selected must identify itself as a systemic review or meta-analysis in the title or abstract and must pertain to sinus augmentation. Thirty-three publications fulfilled the review criteria. The AMSTAR ratings for the 33 chosen reviews scored greater than 3 of 11, with 8 reviews scoring greater or equal to 8 of 11. The outcome of this overview suggested that the following will increase the success of sinus augmentation and survival of implants placed in the grafted sinus: (1) the use of barrier membranes over the lateral window when using a lateral approach to graft the sinus, (2) the use of particulate autogenous bone with or without other substitute graft materials, (3) sinus augmentation without the use of grafting materials may be considered provided that the space between the sinus membrane and floor can be maintained, (4) the use of rough-surfaced implants, (5) simultaneous implant placement with residual bone height greater than 4 mm, and (6) the cessation of smoking.
Fruijtier-Pölloth, Claudia
2012-04-11
Synthetic amorphous silica (SAS), in the form of pyrogenic (fumed), precipitated, gel or colloidal SAS, has been used in a wide variety of industrial and consumer applications including food, cosmetics and pharmaceutical products for many decades. Based on extensive physico-chemical, ecotoxicology, toxicology, safety and epidemiology data, no environmental or health risks have been associated with these materials if produced and used under current hygiene standards and use recommendations. With internal structures in the nanoscale size range, pyrogenic, precipitated and gel SAS are typical examples of nanostructured materials as recently defined by the International Organisation for Standardisation (ISO). The manufacturing process of these SAS materials leads to aggregates of strongly (covalently) bonded or fused primary particles. Weak interaction forces (van der Waals interactions, hydrogen bonding, physical adhesion) between aggregates lead to the formation of micrometre (μm)-sized agglomerates. Typically, isolated nanoparticles do not occur. In contrast, colloidal SAS dispersions may contain isolated primary particles in the nano-size range which can be considered nano-objects. The size of the primary particle resulted in the materials often being considered as "nanosilica" and in the inclusion of SAS in research programmes on nanomaterials. The biological activity of SAS can be related to the particle shape and surface characteristics interfacing with the biological milieu rather than to particle size. SAS adsorbs to cellular surfaces and can affect membrane structures and integrity. Toxicity is linked to mechanisms of interactions with outer and inner cell membranes, signalling responses, and vesicle trafficking pathways. Interaction with membranes may induce the release of endosomal substances, reactive oxygen species, cytokines and chemokines and thus induce inflammatory responses. None of the SAS forms, including colloidal nano-sized particles, were shown to bioaccumulate and all disappear within a short time from living organisms by physiological excretion mechanisms with some indications that the smaller the particle size, the faster the clearance is. Therefore, despite the new nomenclature designating SAS a nanomaterial, none of the recent available data gives any evidence for a novel, hitherto unknown mechanism of toxicity that may raise concerns with regard to human health or environmental risks. Taken together, commercial SAS forms (including colloidal silicon dioxide and surface-treated SAS) are not new nanomaterials with unknown properties, but are well-studied materials that have been in use for decades. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Heritability and intrafamilial aggregation of arterial characteristics.
Seidlerová, Jitka; Bochud, Murielle; Staessen, Jan A; Cwynar, Marcin; Dolejsová, Milena; Kuznetsova, Tatiana; Nawrot, Tim; Olszanecka, Agnieszka; Stolarz, Katarzyna; Thijs, Lutgarde; Wojciechowska, Wiktoria; Struijker-Boudier, Harry A; Kawecka-Jaszcz, Kalina; Elston, Robert C; Fagard, Robert; Filipovský, Jan
2008-04-01
We investigated the heritability and familial aggregation of various indexes of arterial stiffness and wave reflection and we partitioned the phenotypic correlation between these traits into shared genetic and environmental components. Using a family-based population sample, we recruited 204 parents (mean age, 51.7 years) and 290 offspring (29.4 years) from the population in Cracow, Poland (62 families), Hechtel-Eksel, Belgium (36), and Pilsen, the Czech Republic (50). We measured peripheral pulse pressure (PPp) sphygmomanometrically at the brachial artery; central pulse pressure (PPc), the peripheral augmentation indexes (PAIxs) and central augmentation indexes (CAIxs) by applanation tonometry at the radial artery; and aortic pulse wave velocity (PWV) by tonometry or ultrasound. In multivariate-adjusted analyses, we used the ASSOC and PROC GENMOD procedures as implemented in SAGE and SAS, respectively. We found significant heritability for PAIx, CAIx, PPc and mean arterial pressure ranging from 0.37 to 0.41; P < or = 0.0001. The method of intrafamilial concordance confirmed these results; intrafamilial correlation coefficients were significant for all arterial indexes (r > or = 0.12; P < or = 0.02) with the exception of PPc (r = -0.007; P = 0.90) in parent-offspring pairs. The sib-sib correlations were also significant for CAIx (r = 0.22; P = 0.001). The genetic correlation between PWV and the other arterial indexes were significant (rhoG > or = 0.29; P < 0.0001). The corresponding environmental correlations were only significantly positive for PPp (rhoE = 0.10, P = 0.03). The observation of significant intrafamilial concordance and heritability of various indexes of arterial stiffness as well as the genetic correlations among arterial phenotypes strongly support the search for shared genetic determinants underlying these traits.
Quantitative analysis of eyes and other optical systems in linear optics.
Harris, William F; Evans, Tanya; van Gool, Radboud D
2017-05-01
To show that 14-dimensional spaces of augmented point P and angle Q characteristics, matrices obtained from the ray transference, are suitable for quantitative analysis although only the latter define an inner-product space and only on it can one define distances and angles. The paper examines the nature of the spaces and their relationships to other spaces including symmetric dioptric power space. The paper makes use of linear optics, a three-dimensional generalization of Gaussian optics. Symmetric 2 × 2 dioptric power matrices F define a three-dimensional inner-product space which provides a sound basis for quantitative analysis (calculation of changes, arithmetic means, etc.) of refractive errors and thin systems. For general systems the optical character is defined by the dimensionally-heterogeneous 4 × 4 symplectic matrix S, the transference, or if explicit allowance is made for heterocentricity, the 5 × 5 augmented symplectic matrix T. Ordinary quantitative analysis cannot be performed on them because matrices of neither of these types constitute vector spaces. Suitable transformations have been proposed but because the transforms are dimensionally heterogeneous the spaces are not naturally inner-product spaces. The paper obtains 14-dimensional spaces of augmented point P and angle Q characteristics. The 14-dimensional space defined by the augmented angle characteristics Q is dimensionally homogenous and an inner-product space. A 10-dimensional subspace of the space of augmented point characteristics P is also an inner-product space. The spaces are suitable for quantitative analysis of the optical character of eyes and many other systems. Distances and angles can be defined in the inner-product spaces. The optical systems may have multiple separated astigmatic and decentred refracting elements. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.
Sfendla, Anis; Laita, Meriame; Nejjar, Basma; Souirti, Zouhayr; Touhami, Ahami Ahmed Omar; Senhaji, Meftaha
2018-05-01
The extensive accessibility to smartphones in the last decade raises the concerns of addictive behavior patterns toward these technologies worldwide and in developing countries, and Arabic ones in particular. In an area of stigmatized behavior such as Internet and smartphone addiction, the hypothesis extends to whether there is a reliable instrument that can assess smartphone addiction. To our knowledge, no scale in Arabic language is available to assess maladaptive behavior associated with smartphone use. This study aims to assess the factorial validity and internal reliability of the Arabic Smartphone Addiction Scale (SAS) and Smartphone Addiction Scale-Short Version (SAS-SV) in a Moroccan surveyed population. Participants (N = 440 and N = 310) completed an online survey, including SAS, SAS-SV, and questions about sociodemographic status. Factor analysis results showed six factors with factor loading ranging from 0.25 to 0.99 for SAS. Reliability, based on Cronbach's alpha, was excellent (α = 0.94) for this instrument. The SAS-SV showed one factor (unidimensional construct), and internal reliability was in the good range with an alpha coefficient of (α = 0.87). The prevalence of excessive users was 55.8 percent with highest symptom prevalence reported for tolerance and preoccupation. This study proved factor validity of the Arabic SAS and SAS-SV instruments and confirmed their internal reliability.
Investigation of Thrust Augmentation and Acoustic Performance by Ejectors on PDE
NASA Astrophysics Data System (ADS)
Xu, Gui-yang; Weng, Chun-sheng; Li, Ning; Huang, Xiao-long
2016-04-01
Thrust augmentation and acoustic performance of a Pulse Detonation Engine (PDE) with ejector system is experimentally investigated. For these tests the LEjector/DEjector is varied from 1.18 to 4 and the axial placement of the ejector relative to the PDE exhaust is varied from an x/DPDE of -3 to 3. Results from the tests show that the optimum LEjector/DEjector based on thrust augmentation and Overall Sound Pressure Level (OASPL) is found to be 2.61. The divergent ejector performed the best based on thrust augmentation, while the reduction effect for OASPL and Peak Sound Pressure Level (PSPL) at 60° is most prominent for the convergent ejector. The optimum axial position based on thrust augmentation is determined to be x/DPDE = 2, while, x/DPDE = 0 based on OASPL and PSPL.
Low Bandwidth Robust Controllers for Flight
NASA Technical Reports Server (NTRS)
Biezad, Daniel J.; Chou, Hwei-Lan
1993-01-01
Through throttle manipulations, engine thrust can be used for emergency flight control for multi-engine aircraft. Previous study by NASA Dryden has shown the use of throttles for emergency flight control to be very difficult. In general, manual fly-by-throttle is extremely difficult - with landing almost impossible, but control augmentation makes runway landings feasible. Flight path control using throttles-only to achieve safe emergency landing for a large jet transport airplane, Boeing 720, was investigated using Quantitative Feedback Theory (QFT). Results were compared to an augmented control developed in a previous simulation study. The control augmentation corrected the unsatisfactory open-loop characteristics by increasing system bandwidth and damping, but increasing the control bandwidth substantially proved very difficult. The augmented pitch control is robust under no or moderate turbulence. The augmented roll control is sensitive to configuration changes.
Low bandwidth robust controllers for flight
NASA Technical Reports Server (NTRS)
Biezad, Daniel J.; Chou, Hwei-Lan
1993-01-01
Through throttle manipulations, engine thrust can be used for emergency flight control for multi-engine aircraft. Previous study by NASA Dryden has shown the use of throttles for emergency flight control to be very difficult. In general, manual fly-by-throttle is extremely difficult - with landing almost impossible, but control augmentation makes runway landings feasible. Flight path control using throttles-only to achieve safe emergency landing for a large jet transport airplane, Boeing 720, was investigated using Quantitative Feedback Theory (QFT). Results were compared to an augmented control developed in a previous simulation study. The control augmentation corrected the unsatisfactory open-loop characteristics by increasing system bandwidth and damping, but increasing the control bandwidth substantially proved very difficult. The augmented pitch control is robust under no or moderate turbulence. The augmented roll control is sensitive to configuration changes.
DOT National Transportation Integrated Search
1994-12-01
THIS REPORT DOCUMENTS THE DEVELOPMENT OF RECOMMENDATIONS FOR A NATIONAL APPROACH TO AUGMENTED GLOBAL POSITIONING SYSTEM (GPS) SERVICES. THE INSTITUTE FOR TELECOMMUNICATION SCIENCES LED A STUDY TEAM THAT INCLUDED THE U.S. ARMY TOPOGRAPHIC ENGINEERING ...
Computer Augmented Video Education.
ERIC Educational Resources Information Center
Sousa, M. B.
1979-01-01
Describes project CAVE (Computer Augmented Video Education), an ongoing effort at the U.S. Naval Academy to present lecture material on videocassette tape, reinforced by drill and practice through an interactive computer system supported by a 12 channel closed circuit television distribution and production facility. (RAO)
Behavior sensitivities for control augmented structures
NASA Technical Reports Server (NTRS)
Manning, R. A.; Lust, R. V.; Schmit, L. A.
1987-01-01
During the past few years it has been recognized that combining passive structural design methods with active control techniques offers the prospect of being able to find substantially improved designs. These developments have stimulated interest in augmenting structural synthesis by adding active control system design variables to those usually considered in structural optimization. An essential step in extending the approximation concepts approach to control augmented structural synthesis is the development of a behavior sensitivity analysis capability for determining rates of change of dynamic response quantities with respect to changes in structural and control system design variables. Behavior sensitivity information is also useful for man-machine interactive design as well as in the context of system identification studies. Behavior sensitivity formulations for both steady state and transient response are presented and the quality of the resulting derivative information is evaluated.
Identifiability of Additive, Time-Varying Actuator and Sensor Faults by State Augmentation
NASA Technical Reports Server (NTRS)
Upchurch, Jason M.; Gonzalez, Oscar R.; Joshi, Suresh M.
2014-01-01
Recent work has provided a set of necessary and sucient conditions for identifiability of additive step faults (e.g., lock-in-place actuator faults, constant bias in the sensors) using state augmentation. This paper extends these results to an important class of faults which may affect linear, time-invariant systems. In particular, the faults under consideration are those which vary with time and affect the system dynamics additively. Such faults may manifest themselves in aircraft as, for example, control surface oscillations, control surface runaway, and sensor drift. The set of necessary and sucient conditions presented in this paper are general, and apply when a class of time-varying faults affects arbitrary combinations of actuators and sensors. The results in the main theorems are illustrated by two case studies, which provide some insight into how the conditions may be used to check the theoretical identifiability of fault configurations of interest for a given system. It is shown that while state augmentation can be used to identify certain fault configurations, other fault configurations are theoretically impossible to identify using state augmentation, giving practitioners valuable insight into such situations. That is, the limitations of state augmentation for a given system and configuration of faults are made explicit. Another limitation of model-based methods is that there can be large numbers of fault configurations, thus making identification of all possible configurations impractical. However, the theoretical identifiability of known, credible fault configurations can be tested using the theorems presented in this paper, which can then assist the efforts of fault identification practitioners.
Dong, Xing; Zhang, Kevin; Ren, Yuan; Wilson, Reda; O'Neil, Mary Elizabeth
2016-01-01
Studying population-based cancer survival by leveraging the high-quality cancer incidence data collected by the Centers for Disease Control and Prevention's National Program of Cancer Registries (NPCR) can offer valuable insight into the cancer burden and impact in the United States. We describe the development and validation of a SASmacro tool that calculates population-based cancer site-specific relative survival estimates comparable to those obtained through SEER*Stat. The NPCR relative survival analysis SAS tool (NPCR SAS tool) was developed based on the relative survival method and SAS macros developed by Paul Dickman. NPCR cancer incidence data from 25 states submitted in November 2012 were used, specifically cases diagnosed from 2003 to 2010 with follow-up through 2010. Decennial and annual complete life tables published by the National Center for Health Statistics (NCHS) for 2000 through 2009 were used. To assess comparability between the 2 tools, 5-year relative survival rates were calculated for 25 cancer sites by sex, race, and age group using the NPCR SAS tool and the National Cancer Institute's SEER*Stat 8.1.5 software. A module to create data files for SEER*Stat was also developed for the NPCR SAS tool. Comparison of the results produced by both SAS and SEER*Stat showed comparable and reliable relative survival estimates for NPCR data. For a majority of the sites, the net differences between the NPCR SAS tool and SEER*Stat-produced relative survival estimates ranged from -0.1% to 0.1%. The estimated standard errors were highly comparable between the 2 tools as well. The NPCR SAS tool will allow researchers to accurately estimate cancer 5-year relative survival estimates that are comparable to those produced by SEER*Stat for NPCR data. Comparison of output from the NPCR SAS tool and SEER*Stat provided additional quality control capabilities for evaluating data prior to producing NPCR relative survival estimates.
Zhao, Zhi; Xie, Jingming; Wang, Yingsong; Bi, Ni; Li, Tao; Zhang, Ying; Shi, Zhiyue
2017-07-01
In using posterior vertebral column resection (PVCR) to treat severe kyphoscoliosis, it is unavoidable to ligate and cut off several segmental arteries (SAs) of the spinal cord for exposure and hemostasis, but which would raise the neurological risks. The aim of this study is to explore the changes of intraoperative spinal cord monitoring (IOM) following ligating different numbers of SAs in PVCR. Twenty-one consecutive patients with severe kyphoscoliosis were included and treated by PVCR correction. In operation, according to ligate different numbers of SAs, the IOM changes were recorded, respectively. Examinations of the covariance between different numbers of SAs ligations and IOM changes were performed to reveal the effect to the spinal cord by SAs ligations. In all the 21 cases, averaging 1.9 pairs of SAs were ligated. With the increased numbers of ligations, SSEP amplitudes and latencies were changed more obviously: from 1 to 3 pairs ligations, the mean decreased percentages of amplitudes were from 53.20 to 78.15%, the mean increased percentages of latency were from 1.23 to 1.40%, and the mean durations of decreased SSEP amplitudes were from 3.23 to 5.2 min; but without abnormal MEP changes. None occurred postoperative or delayed neurological deficit. Correlation analysis identified significant correlations between the number of SAs ligation and decreased percentage of SSEP amplitude (r = 0.945, P < 0.0001), and between the number of SAs being ligated and the duration of SSEP change (r = 0.945, P = 0.0002). Following the increased number of SAs ligation, the amplitude of SSEP is decreased more obviously with a much longer duration of recovery and the risk to spinal cord will be increased greatly. In the PVCR correction on the basis of spinal shortening, the numbers of SAs ligations should be as less as possible for neurological safety.
Sensor fusion and augmented reality with the SAFIRE system
NASA Astrophysics Data System (ADS)
Saponaro, Philip; Treible, Wayne; Phelan, Brian; Sherbondy, Kelly; Kambhamettu, Chandra
2018-04-01
The Spectrally Agile Frequency-Incrementing Reconfigurable (SAFIRE) mobile radar system was developed and exercised at an arid U.S. test site. The system can detect hidden target using radar, a global positioning system (GPS), dual stereo color cameras, and dual stereo thermal cameras. An Augmented Reality (AR) software interface allows the user to see a single fused video stream containing the SAR, color, and thermal imagery. The stereo sensors allow the AR system to display both fused 2D imagery and 3D metric reconstructions, where the user can "fly" around the 3D model and switch between the modalities.
Richardson, Matthew Allen; Rousso, Daniel Elliott; Replogle, William H
2017-01-01
To our knowledge, long-term, objective results of lip augmentation using superficial musculoaponeurotic system (SMAS) tissue transfer beyond 1 year have not been previously described. To evaluate the efficacy, longevity, and safety of lip augmentation using SMAS tissue transfer. A retrospective single-blind cohort study was designed to evaluate all patients who underwent surgical lip augmentation using SMAS following rhytidectomy between January 1, 2000, and November, 16, 2015, at a private facial plastic surgery practice in Birmingham, Alabama. Preoperative photographs of each patient served as controls and were compared with postoperative photographs at 3 months, 1 year, and 5 years after lip augmentation. A total of 104 images (from 26 individual patients) were reviewed by 12 blinded observers using a validated lip augmentation grading scale. Lip augmentation using SMAS. Median lip volumes of all patients at each postoperative interval (3 months, 1 year, and 5 years) compared with preoperative lip volumes. Secondary outcome measures included postoperative complications. A total of 423 patients were identified who underwent surgical lip augmentation using SMAS. Sixty patients with approximately 5 years or more of postoperative photographs were reviewed for complications. Twenty-six patients had 3-month, 1-year, and 5-year postoperative follow-up photographs and were included in the photographic evaluation. The mean age of these patients at the time of surgery was 54.6 years (range, 41.2-80.6 years. Fifty-nine of the 60 patients (98.3%) were female. Two of 60 patients (3.3%) with 5 years or more of postoperative follow-up developed complications requiring intervention. Both the superior lip and the inferior lip showed statistically significant increases in volume at 3 months, 1 year, and 5 years (P ≤ .004 for the superior lip after 5 years; P ≤ .001 for all other comparisons) after SMAS lip augmentation. The greatest median increase was observed in the superior lip at 3 months, while the smallest median increase was observed for the inferior lip at 5 years. The degree of increase in median volume seemed to weaken slightly over time, but remained statistically significant even at 5 years. SMAS lip augmentation is an effective and safe method for lip augmentation that can yield natural, long-lasting results with minimal risk. The degree of augmentation tends to fade slightly over time, but remains significant for at least 5 years postoperatively. 3.
TDRSS Augmentation Service for Satellites (TASS)
NASA Technical Reports Server (NTRS)
Heckler, Gregory W.; Gramling, Cheryl; Valdez, Jennifer; Baldwin, Philip
2016-01-01
In 2015, NASA Goddard Space Flight Center (GSFC) reinvigorated the development of the TDRSS Augmentation Service for Satellites (TASS). TASS is a global, space-based, communications and navigation service for users of Global Navigation Satellite Systems (GNSS) and the Tracking and Data Relay Satellite System (TDRSS). TASS leverages the existing TDRSS to provide an S-band beacon radio navigation and messaging source to users at orbital altitudes 1400 km and below.
NASA Technical Reports Server (NTRS)
Willis, W. S.; Konarski, M.; Sutherland, M. V.
1982-01-01
Ejector concepts for use with a remote augmented lift system (RALS) exhaust nozzle were studied. A number of concepts were considered and three were selected as having the greatest promise of providing the desired aircraft and exhaust gas cooling and lift enhancement. A scale model test program is recommended to explore the effects of the more important parameters on ejector performance.
The future of radiology augmented with Artificial Intelligence: A strategy for success.
Liew, Charlene
2018-05-01
The rapid development of Artificial Intelligence/deep learning technology and its implementation into routine clinical imaging will cause a major transformation to the practice of radiology. Strategic positioning will ensure the successful transition of radiologists into their new roles as augmented clinicians. This paper describes an overall vision on how to achieve a smooth transition through the practice of augmented radiology where radiologists-in-the-loop ensure the safe implementation of Artificial Intelligence systems. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Hensley, Douglas; Creighton, Thomas; Haddad, Raphael; Hendrich, Louis; Morgan, Louise; Russell, Mark; Swift, Gerald
1987-01-01
The methodology and results for a flight control design and implementation for common handling qualities by Separate Surface Stability Augmentation (SSSA) for the family of commuter airplanes are contained. The open and closed loop dynamics and the design results of augmenting for common handling qualities are presented. The physical and technology requirements are presented for implementing the SSSA system. The conclusion of this report and recommendations for changes or improvement are discussed.
NASA Astrophysics Data System (ADS)
Sun, Limin; Chen, Lin
2017-10-01
Residual mode correction is found crucial in calibrating linear resonant absorbers for flexible structures. The classic modal representation augmented with stiffness and inertia correction terms accounting for non-resonant modes improves the calibration accuracy and meanwhile avoids complex modal analysis of the full system. This paper explores the augmented modal representation in calibrating control devices with nonlinearity, by studying a taut cable attached with a general viscous damper and its Equivalent Dynamic Systems (EDSs), i.e. the augmented modal representations connected to the same damper. As nonlinearity is concerned, Frequency Response Functions (FRFs) of the EDSs are investigated in detail for parameter calibration, using the harmonic balance method in combination with numerical continuation. The FRFs of the EDSs and corresponding calibration results are then compared with those of the full system documented in the literature for varied structural modes, damper locations and nonlinearity. General agreement is found and in particular the EDS with both stiffness and inertia corrections (quasi-dynamic correction) performs best among available approximate methods. This indicates that the augmented modal representation although derived from linear cases is applicable to a relatively wide range of damper nonlinearity. Calibration of nonlinear devices by this means still requires numerical analysis while the efficiency is largely improved owing to the system order reduction.
The eye in sleep apnea syndrome.
Abdal, Helen; Pizzimenti, Joseph J; Purvis, Cheryl C
2006-03-01
Sleep apnea syndrome (SAS) is a disease characterized by recurrent complete or partial upper airway obstructions during sleep. The majority of patients with SAS demonstrate this obstruction either at the nasopharynx or the oropharynx. Risk factors for SAS include obesity, male gender, upper airway abnormalities, alcohol use, snoring, and neck girth of more than 17 in. in men or 16 in. in women. Reported ophthalmic findings in patients with SAS include floppy eyelid syndrome (FES), glaucoma, and non-arteritic anterior ischemic optic neuropathy (NAION).
Therapeutics: Alpha-1 Antitrypsin Augmentation Therapy.
Campos, Michael; Lascano, Jorge
2017-01-01
Subjects with alpha-1 antitrypsin deficiency who develop pulmonary disease are managed following general treatment guidelines, including disease management interventions. In addition, administration of intravenous infusions of alpha-1 proteinase inhibitor (augmentation therapy) at regular schedules is a specific therapy for individuals with AATD with pulmonary involvement.This chapter summarizes the manufacturing differences of commercially available formulations and the available evidence of the effects of augmentation therapy. Biologically, there is clear evidence of in vivo local antiprotease effects in the lung and systemic immunomodulatory effects. Clinically, there is cumulative evidence of slowing lung function decline and emphysema progression. The optimal dose of augmentation therapy is being revised as well as more individualized assessment of who needs this therapy.
Utilization of the Space Vision System as an Augmented Reality System For Mission Operations
NASA Technical Reports Server (NTRS)
Maida, James C.; Bowen, Charles
2003-01-01
Augmented reality is a technique whereby computer generated images are superimposed on live images for visual enhancement. Augmented reality can also be characterized as dynamic overlays when computer generated images are registered with moving objects in a live image. This technique has been successfully implemented, with low to medium levels of registration precision, in an NRA funded project entitled, "Improving Human Task Performance with Luminance Images and Dynamic Overlays". Future research is already being planned to also utilize a laboratory-based system where more extensive subject testing can be performed. However successful this might be, the problem will still be whether such a technology can be used with flight hardware. To answer this question, the Canadian Space Vision System (SVS) will be tested as an augmented reality system capable of improving human performance where the operation requires indirect viewing. This system has already been certified for flight and is currently flown on each shuttle mission for station assembly. Successful development and utilization of this system in a ground-based experiment will expand its utilization for on-orbit mission operations. Current research and development regarding the use of augmented reality technology is being simulated using ground-based equipment. This is an appropriate approach for development of symbology (graphics and annotation) optimal for human performance and for development of optimal image registration techniques. It is anticipated that this technology will become more pervasive as it matures. Because we know what and where almost everything is on ISS, this reduces the registration problem and improves the computer model of that reality, making augmented reality an attractive tool, provided we know how to use it. This is the basis for current research in this area. However, there is a missing element to this process. It is the link from this research to the current ISS video system and to flight hardware capable of utilizing this technology. This is the basis for this proposed Space Human Factors Engineering project, the determination of the display symbology within the performance limits of the Space Vision System that will objectively improve human performance. This utilization of existing flight hardware will greatly reduce the costs of implementation for flight. Besides being used onboard shuttle and space station and as a ground-based system for mission operational support, it also has great potential for science and medical training and diagnostics, remote learning, team learning, video/media conferencing, and educational outreach.
Treatment of complex sleep apnea syndrome: a retrospective comparative review.
Pusalavidyasagar, Snigdha S; Olson, Eric J; Gay, Peter C; Morgenthaler, Timothy I
2006-09-01
Some patients with obstructive sleep apnea syndrome (OSAS) develop problematic central apneas or Cheyne-Stokes pattern with acute application of continuous positive airway pressure (CPAP), herein called complex sleep apnea syndrome (CompSAS). This response makes it difficult to be certain that CPAP will be a successful treatment strategy. We sought to compare treatments between patients with CompSAS vs. OSAS and hypothesized that CompSAS patients would find CPAP less effective and have more problems with adherence than patients with OSAS. We performed a retrospective review of patients studied in our sleep disorders center over 1 month. There were 133 patients with OSAS (mean age=57.6+/-12.2 years; males=63.9%) and 34 with CompSAS (mean age=54.4+/-16 years; males=82.35%). CPAP was prescribed in 93.7 and 87.9% of OSAS and CompSAS patients, respectively (P=0.284), with no significant difference in required CPAP pressures (P=0.112). There was no difference in prescription frequency of alternative therapies. Mean time to the first follow-up was shorter in CompSAS patients (46.2+/-47.3 vs. 53.8+/-36.8 days; P=0.022). CPAP compliance in OSAS and CompSAS patients (5.1+/-1.6 vs. 6.1+/-1.5h, P=0.156) and improvement in Epworth Sleepiness Scale (ESS) (-4.6+/-4.8 vs. -5.9+/-6.9, P=0.483) was similar. However, interface problems were more common in CompSAS patients, especially air hunger/dyspnea (0.8 vs. 8.8%) and inadvertent mask removal (2.6 vs. 17.7%) (all P<0.050). CompSAS patients have more CPAP interface problems and require more follow-up than OSAS patients but with intervention may have similar treatment results compared to patients with OSAS.
Guichard, Yves; Maire, Marie-Aline; Sébillaud, Sylvie; Fontana, Caroline; Langlais, Cristina; Micillino, Jean-Claude; Darne, Christian; Roszak, Joanna; Stępnik, Maciej; Fessard, Valérie; Binet, Stéphane; Gaté, Laurent
2015-03-01
Synthetic amorphous silica nanomaterials (SAS) are extensively used in food and tire industries. In many industrial processes, SAS may become aerosolized and lead to occupational exposure of workers through inhalation in particular. However, little is known about the in vivo genotoxicity of these particulate materials. To gain insight into the toxicological properties of four SAS (NM-200, NM-201, NM-202, and NM-203), rats are treated with three consecutive intratracheal instillations of 3, 6, or 12 mg/kg of SAS at 48, 24, and 3 hrs prior to tissue collection (cumulative doses of 9, 18, and 36 mg/kg). Deoxyribonucleic acid (DNA) damage was assessed using erythrocyte micronucleus test and the standard and Fpg-modified comet assays on cells from bronchoalveolar lavage fluid (BALF), lung, blood, spleen, liver, bone marrow, and kidney. Although all of the SAS caused increased dose-dependent changes in lung inflammation as demonstrated by BALF neutrophilia, they did not induce any significant DNA damage. As the amount of SAS reaching the blood stream and subsequently the internal organs is probably to be low following intratracheal instillation, an additional experiment was performed with NM-203. Rats received three consecutive intravenous injections of 5, 10, or 20 mg/kg of SAS at 48, 24, and 3 hrs prior to tissue collection. Despite the hepatotoxicity, thrombocytopenia, and even animal death induced by this nanomaterial, no significant increase in DNA damage or micronucleus frequency was observed in SAS-exposed animals. It was concluded that under experimental conditions, SAS induced obvious toxic effects but did cause any genotoxicity following intratracheal instillation and intravenous injection. © 2014 Wiley Periodicals, Inc.
Nakazaki, Chie; Noda, Akiko; Yasuda, Yoshinari; Nakata, Seiichi; Koike, Yasuo; Yasuma, Fumihiko; Murohara, Toyoaki; Nakashima, Tsutomu
2012-09-01
Complex sleep apnea syndrome (CompSAS) is diagnosed after an elimination of obstructive events with continuous positive airway pressure (CPAP), when a central apnea index ≥5/h or Cheyne-Stokes respiration pattern emerges in patients with obstructive sleep apnea syndrome (OSAS). However, the pathophysiology of CompSAS remains controversial. Of the 281 patients with suspected OSAS, all of whom underwent polysomnography conducted at Nagoya University Hospital, we enrolled 52 patients with apnea-hypopnea index ≥15/h (age 51.4 ± 13.3 years). The polysomnographic findings, left ventricular ejection fraction (LVEF), and nasal resistance were compared between the CompSAS patients and OSAS patients. Forty-three patients were diagnosed with OSAS and nine patients with central sleep apnea syndrome by natural sleep PSG. Furthermore, 43 OSAS patients were classified into the OSAS patients (OSAS group, n = 38) and the CompSAS patients (CompSAS group, n = 5) by the night on CPAP PSG. The nasal resistance was significantly higher in CompSAS group than in OSAS group (0.30 ± 0.10 vs. 0.19 ± 0.07 Pa/cm(3)/s, P = 0.004). The arousal index, percentage of stage 1 sleep, and oxygen desaturation index were significantly decreased, and the percentage of stage REM sleep was significantly increased in the OSAS group with the initial CPAP treatment, but not in the CompSAS group. In addition, the patients with CompSAS showed normal LVEF. CPAP intolerance secondary to an elevated nasal resistance might relate to frequent arousals, which could presumably contribute to an increase in central sleep apnea. Further evaluation in a large study is needed to clarify the mechanism of CompSAS.
The small tellurium-based compound SAS suppresses inflammation in human retinal pigment epithelium
Livnat, Tami; Halpert, Gilad; Jawad, Shayma; Nisgav, Yael; Azar-Avivi, Shirley; Liu, Baoying; Nussenblatt, Robert B.; Weinberger, Dov; Sredni, Benjamin
2016-01-01
Purpose Pathological angiogenesis and chronic inflammation greatly contribute to the development of choroidal neovascularization (CNV) in chorioretinal diseases involving abnormal contact between retinal pigment epithelial (RPE) and endothelial cells (ECs), associated with Bruch’s membrane rupture. We explored the ability of the small organotellurium compound octa-O-bis-(R,R)-tartarate ditellurane (SAS) to mitigate inflammatory processes in human RPE cells. Methods Cell adhesion assays and analyses of gene and protein expression were used to examine the effect of SAS on ARPE-19 cells or primary human RPE cells that were grown alone or in an RPE-EC co-culture. Results Adhesion assays showed that SAS inhibited αv integrins expressed on RPE cells. Co-cultures of RPE cells with ECs significantly reduced the gene expression of PEDF, as compared to RPE cells cultured alone. Both SAS and the anti-αvβ3 antibody LM609 significantly enhanced the production of PEDF at both mRNA and protein levels in RPE cells. RPE cells co-cultured with EC exhibited increased gene expression of CXCL5, COX1, MMP2, IGF1, and IL8, all of which are involved in both angiogenesis and inflammation. The enhanced expression of these genes was greatly suppressed by SAS, but interestingly, remained unaffected by LM609. Zymography assay showed that SAS reduced the level of MMP-2 activity in RPE cells. We also found that SAS significantly suppressed IL-1β-induced IL-6 expression and secretion from RPE cells by reducing the protein levels of phospho-IkappaBalpha (pIκBα). Conclusions Our results suggest that SAS is a promising anti-inflammatory agent in RPE cells, and may be an effective therapeutic approach for controlling chorioretinal diseases. PMID:27293373
The small tellurium-based compound SAS suppresses inflammation in human retinal pigment epithelium.
Dardik, Rima; Livnat, Tami; Halpert, Gilad; Jawad, Shayma; Nisgav, Yael; Azar-Avivi, Shirley; Liu, Baoying; Nussenblatt, Robert B; Weinberger, Dov; Sredni, Benjamin
2016-01-01
Pathological angiogenesis and chronic inflammation greatly contribute to the development of choroidal neovascularization (CNV) in chorioretinal diseases involving abnormal contact between retinal pigment epithelial (RPE) and endothelial cells (ECs), associated with Bruch's membrane rupture. We explored the ability of the small organotellurium compound octa-O-bis-(R,R)-tartarate ditellurane (SAS) to mitigate inflammatory processes in human RPE cells. Cell adhesion assays and analyses of gene and protein expression were used to examine the effect of SAS on ARPE-19 cells or primary human RPE cells that were grown alone or in an RPE-EC co-culture. Adhesion assays showed that SAS inhibited αv integrins expressed on RPE cells. Co-cultures of RPE cells with ECs significantly reduced the gene expression of PEDF, as compared to RPE cells cultured alone. Both SAS and the anti-αvβ3 antibody LM609 significantly enhanced the production of PEDF at both mRNA and protein levels in RPE cells. RPE cells co-cultured with EC exhibited increased gene expression of CXCL5, COX1, MMP2, IGF1, and IL8, all of which are involved in both angiogenesis and inflammation. The enhanced expression of these genes was greatly suppressed by SAS, but interestingly, remained unaffected by LM609. Zymography assay showed that SAS reduced the level of MMP-2 activity in RPE cells. We also found that SAS significantly suppressed IL-1β-induced IL-6 expression and secretion from RPE cells by reducing the protein levels of phospho-IkappaBalpha (pIκBα). Our results suggest that SAS is a promising anti-inflammatory agent in RPE cells, and may be an effective therapeutic approach for controlling chorioretinal diseases.
Li, Shipeng; Sun, Jing; Zhang, Jianzhong; Li, Xiangmei; Tao, Xiaoxia; Wang, Lijuan; Sun, Mingjiao; Liu, Yingchao; Li, Juan; Qiao, Yanhong; Yu, Sangjie; Yao, Kaihu; Yang, Yonghong; Shen, Xuzhuang
2014-02-01
This study aims to investigate the prevalence of a novel cell wall-anchored protein gene, sasX, and to obtain information on the genetic basis for the pathogenic potential of the MRSA strains isolated from Chinese children. The molecular and virulence characteristics of the clinical strains were analyzed. Twenty-two sequence types (STs) were obtained, with six epidemic clones ST59, ST239, ST1, ST910, ST88, and ST338 accounting for 35.8, 22, 6.6, 6.6, 5.3, and 4.1% respectively. The expression levels of hla, psmα, and RNAIII were higher in ST59 than in other STs (p < 0.05). The sasX gene was detected in 26 (10.7%) MRSA isolates. ST239-MRSA-SCCmecIII-t037 (61.5%) was the predominant sasX-positive MRSA clone. The expressions of PSMα and RNAIII were higher in sasX-positive ST239 isolates than in sasX-negative ST239 ones (p < 0.01). Notably, the percentage of invasive infection in infections caused by sasX-positive ST239 MRSA was higher than that by sasX-negative ST239 MRSA (p = 0.008). This study indicated that ST59 was the predominant clone in the MRSA isolates obtained from Chinese children and might have stronger pathogenic potential. The prevalence of the sasX gene in the MRSA isolates from children was relatively low. Furthermore, the sasX gene might be related to the expressions of PSMα and RNAIII and infection invasiveness. © 2013 APMIS Published by John Wiley & Sons Ltd.
Javard, Romain; Bélanger, Marie-Claude; Côté, Etienne; Beauchamp, Guy; Pibarot, Philippe
2014-12-15
To evaluate the usefulness of Doppler-derived peak flow velocity through the left ventricular outflow tract (LVOT Vmax) and effective orifice area indexed to body surface area (EOAi) in puppies to predict development of subaortic stenosis (SAS) in the same dogs as adults. Prospective, longitudinal, observational study. 38 Golden Retrievers. Cardiac auscultation and echocardiography were performed on 2- to 6-month-old puppies, then repeated at 12 to 18 months. Subaortic stenosis was diagnosed when LVOT Vmax was ≥ 2.3 m/s in adult dogs with left basilar systolic murmurs. All puppies with EOAi < 1.46 cm(2)/m(2) had SAS as adults. All adults with EOAi < 1.29 cm(2)/m(2) had SAS. An LVOT Vmax > 2.3 m/s in puppyhood was 63% sensitive and 100% specific for SAS in adulthood. In puppies, LVOT Vmax was more strongly associated with a future diagnosis of SAS (area under the curve [AUC], 0.89) than was EOAi (AUC, 0.80). In puppies, the combination of LVOT Vmax and EOAi yielded slightly higher sensitivity (69%) and specificity (100%) for adult SAS than did LVOT Vmax alone. In unaffected and affected dogs, LVOT Vmax increased significantly from puppyhood to adulthood but EOAi did not. In Golden Retriever puppies, LVOT Vmax > 2.3 m/s and EOAi < 1.46 cm(2)/m(2) were both associated with a diagnosis of SAS at adulthood. The combination of these 2 criteria may result in higher sensitivity for SAS screening. Unlike LVOT Vmax, EOAi did not change during growth in either unaffected Golden Retrievers or those with SAS.
[Toward innovative hospital care].
Loudcher, Rose-Marie; Tebib-Chibani, Yasmine
2017-10-01
For healthcare financing to remain profitable and to continue to function, the care system must be innovative in terms of patient care. Work organisation has changed with the pricing system for medical acts. The system of enhanced recovery after surgery helps to reduce hospitalisation times and to reflect on organisation. Nurses are on the front line. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
The effect of in situ augmentation on implant anchorage in proximal humeral head fractures.
Unger, Stefan; Erhart, Stefanie; Kralinger, Franz; Blauth, Michael; Schmoelz, Werner
2012-10-01
Fracture fixation in patients suffering from osteoporosis is difficult as sufficient implant anchorage is not always possible. One method to enhance implant anchorage is implant/screw augmentation with PMMA-cement. The present study investigated the feasibility of implant augmentation with PMMA-cement to enhance implant anchorage in the proximal humerus. A simulated three part humeral head fracture was stabilised with an angular stable plating system in 12 pairs of humeri using six head screws. In the augmentation group the proximal four screws were treated with four cannulated screws, each augmented with 0.5ml of PMMA-cement, whereas the contra lateral side served as a non-augmented control. Specimens were loaded in varus-bending or axial-rotation using a cyclic loading protocol with increasing load magnitude until failure of the osteosynthesis occurred. Augmented specimens showed a significant higher number of load cycles until failure than non-augment specimens (varus-bending: 8516 (SD 951.6) vs. 5583 (SD 2273.6), P=0.014; axial-rotation: 3316 (SD 348.8) vs. 2050 (SD 656.5), P=0.003). Non-augmented specimens showed a positive correlation of load cycles until failure and measured bone mineral density (varus-bending: r=0.893, P=0.016; axial-rotation: r=0.753, P=0.084), whereas no correlation was present in augmented specimens (varus-bending: r=0,258, P=0.621; axial-rotation r=0.127, P=0.810). These findings suggest that augmentation of cannulated screws is a feasible method to enhance implant/screw anchorage in the humeral head. The improvement of screw purchase is increasing with decreasing bone mineral density. Copyright © 2012 Elsevier Ltd. All rights reserved.
Numerical Modeling of Ophthalmic Response to Space
NASA Technical Reports Server (NTRS)
Nelson, E. S.; Myers, J. G.; Mulugeta, L.; Vera, J.; Raykin, J.; Feola, A.; Gleason, R.; Samuels, B.; Ethier, C. R.
2015-01-01
To investigate ophthalmic changes in spaceflight, we would like to predict the impact of blood dysregulation and elevated intracranial pressure (ICP) on Intraocular Pressure (IOP). Unlike other physiological systems, there are very few lumped parameter models of the eye. The eye model described here is novel in its inclusion of the human choroid and retrobulbar subarachnoid space (rSAS), which are key elements in investigating the impact of increased ICP and ocular blood volume. Some ingenuity was required in modeling the blood and rSAS compartments due to the lack of quantitative data on essential hydrodynamic quantities, such as net choroidal volume and blood flowrate, inlet and exit pressures, and material properties, such as compliances between compartments.
Neurology of microgravity and space travel
NASA Technical Reports Server (NTRS)
Fujii, M. D.; Patten, B. M.
1992-01-01
Exposure to microgravity and space travel produce several neurologic changes, including SAS, ataxia, postural disturbances, perceptual illusions, neuromuscular weakness, and fatigue. Inflight SAS, perceptual illusions, and ocular changes are of more importance. After landing, however, ataxia, perceptual illusions, neuromuscular weakness, and fatigue play greater roles in astronaut health and readaptation to a terrestrial environment. Cardiovascular adjustments to microgravity, bone demineralization, and possible decompression sickness and excessive radiation exposure contribute further to medical problems of astronauts in space. A better understanding of the mechanisms by which microgravity adversely affects the nervous system and more effective treatments will provide healthier, happier, and longer stays in space on the space station Freedom and during the mission to Mars.
[Extending the palliative approach across the French health system].
Mino, Jean-Christophe
2015-11-01
The care provision for people at the end of life requires a palliative care approach to be extended across the whole healthcare system. Access to palliative care for everyone requires training for professionals, support for specialised structures and teams as well as clear political will. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system.
Sugawara, Junji; Kanzaki, Reiko; Takahashi, Ichiro; Nagasaka, Hiroshi; Nanda, Ravindra
2006-06-01
It is now possible to predictably move maxillary molars distally in nongrowing patients with the skeletal anchorage system (SAS) and to improve malocclusions without having to extract the premolars and regardless of the patient's compliance. The purposes of this study were to investigate the amount of distal movement of the maxillary first molars, the type of movement, the difference between actual and predicted amounts of distalization, and the relationship between the amount of distalization and age. Twenty-five nongrowing patients (22 female, 3 male) successfully treated with the SAS were the subjects in this study. The amount and the type of distalization, the difference between predicted and resulting amounts of distalization, and the relationship between the patient's age and the amount of distalization were analyzed with wide-opening cephalometric radiographs. The average amount of distalization of the maxillary first molars was 3.78 mm at the crown level and 3.20 mm at the root level. The amount of distalization at the crown level was significantly correlated with the average value of treatment goals (3.60 mm). The maxillary molars were predictably distalized in accordance with the individualized treatment goals without regard to patient age and extraction of the third or second molars. The SAS is a viable noncompliance modality to move maxillary molars for distally correcting maxillary protrusions and malocclusions characterized by maxillary incisor crowding.
South Asian ethnicity and cardiovascular risk: the known, the unknown, and the paradox.
Ahmed, Emad; El-Menyar, Ayman
2015-05-01
South Asians (SAs), in their countries or after migration, are at high risk of coronary artery disease (CAD) and mortality compared to other ethnic groups. It has been shown that >90% of CAD global risk could be attributed to 9 modifiable risk factors (RFs) worldwide. However, these conventional RFs may not fully explain this high risk of CAD among SAs. Therefore, attention has been directed toward nonconventional RFs. In this narrative review, we evaluate the conventional and emerging cardiovascular RFs characterizing SAs. These factors may explain the high morbidity and mortality among SAs. Further prospective studies are urgently needed to set algorithms for the optimal management of these RFs in high-risk populations like SAs. © The Author(s) 2014.
SAS-1 Is a C2 Domain Protein Critical for Centriole Integrity in C. elegans
Delattre, Marie; Balestra, Fernando R.; Blanchoud, Simon; Finger, Susanne; Knott, Graham; Müller-Reichert, Thomas; Gönczy, Pierre
2014-01-01
Centrioles are microtubule-based organelles important for the formation of cilia, flagella and centrosomes. Despite progress in understanding the underlying assembly mechanisms, how centriole integrity is ensured is incompletely understood, including in sperm cells, where such integrity is particularly critical. We identified C. elegans sas-1 in a genetic screen as a locus required for bipolar spindle assembly in the early embryo. Our analysis reveals that sperm-derived sas-1 mutant centrioles lose their integrity shortly after fertilization, and that a related defect occurs when maternal sas-1 function is lacking. We establish that sas-1 encodes a C2 domain containing protein that localizes to centrioles in C. elegans, and which can bind and stabilize microtubules when expressed in human cells. Moreover, we uncover that SAS-1 is related to C2CD3, a protein required for complete centriole formation in human cells and affected in a type of oral-facial-digital (OFD) syndrome. PMID:25412110
Uliano, D; Falciglia, G; Del Viscio, C; Picelli, A; Gandolfi, M; Passarella, A
2010-06-01
Augmentative and alternative communication devices proved to be effective in patients with severe intellectual disability to overcome their communication impairments. In order to give a contribution for design of augmentative and alternative communication systems that better meet the needs of beginning communicators we decided to report our clinical experience about using augmentative and alternative communication in adolescents with severe intellectual disability. Five patients who underwent a long time traditional speech rehabilitation program (at least 5 years) with scant improvements in linguistic function were recruited and evaluated by means of the Vineland Adaptive Behaviour Scale before and after a three years augmentative and alternative communication intervention carried out by a multidisciplinary team. After the rehabilitative intervention patients showed an improvement in communication, daily living skills and socialization as measured by the Vineland Adaptive Behaviour Scale. Augmentative and alternative communication is an effective rehabilitation approach to people with severe intellectual disability and impairments in linguistic expression. Moreover augmentative and alternative communication is a useful tool allowing these patients to increase their social participation also enhancing their self-esteem. Our clinical experience confirmed these topics also in adolescents who underwent a long time traditional speech rehabilitation program with scant improvements, providing practical information to clinicians.
From Uhuru at CfA to SAS-3 at MIT: Looking for X-Ray Binaries in all the Right Places
NASA Astrophysics Data System (ADS)
Cominsky, Lynn R.
2013-01-01
My career in X-ray astronomy started almost accidentally, when in 1975 I was hired fresh out of college as a “data aide” for the Uhuru satellite, in Riccardo Giacconi’s group at the Harvard-Smithsonian Center for Astrophysics. Working first for Mel Ulmer, and later for Bill Forman and Christine Jones, I learned the fundamentals of data analysis, and helped produce the Fourth Uhuru catalog of X-ray sources (Forman et al. 1978), as well as studying transient X-ray sources (Cominsky et al. 1978). Christine was the first woman scientist I had ever met, and with her encouragement, I applied to graduate school to continue on in X-ray astronomy. Lured down the street to MIT by the chance to work on SAS-3, I eagerly learned how to operate the satellite from a control room in the Center for Space Research. The SAS-3 group was led by Prof. George Clark, and it was my good luck that he was around during the holiday break in January 1978 when everyone else in the group was at an AAS meeting in Hawaii. A source I recognized from my Uhuru work, 4U0115+63, had reappeared, and I knew that it was likely to be a pulsar. With the help of George and Project Scientist Bill Mayer, I managed to send the commands to stop SAS-3 and point at the source. The 3.6 second pulsations were so strong that they could be seen in the raw data! This discovery made the New York Times, as 4U0115+63 was the first transient x-ray source shown to be in a binary system (Cominsky et al. 1978, Rappaport et al. 1978). Another personal SAS-3 highlight included working on Prof. Walter Lewin’s “World-wide Burst Watch” - coordinated multi-wavelength observations of x-ray burst sources which led to the discoveries of slightly delayed but coincident optical bursts (Grindlay et al. 1978, McClintock et al. 1979). Although live operations of SAS-3 ended when it re-entered on April 9, 1979, many years of additional data analysis remained. And later, as a continuation of work I began in my Ph.D. Thesis on X-ray burst sources, I used SAS-3 data together with data from HEAO A-1 to discover the first true eclipses from an x-ray burster (MXB1659-29, Cominsky and Wood 1984), providing definitive evidence of the binary nature of a second class of x-ray sources.
Duan, Liya; Guan, Tao; Yang, Bo
2009-01-01
Augmented reality (AR) is a field of computer research which deals with the combination of real world and computer generated data. Registration is one of the most difficult problems currently limiting the usability of AR systems. In this paper, we propose a novel natural feature tracking based registration method for AR applications. The proposed method has following advantages: (1) it is simple and efficient, as no man-made markers are needed for both indoor and outdoor AR applications; moreover, it can work with arbitrary geometric shapes including planar, near planar and non planar structures which really enhance the usability of AR systems. (2) Thanks to the reduced SIFT based augmented optical flow tracker, the virtual scene can still be augmented on the specified areas even under the circumstances of occlusion and large changes in viewpoint during the entire process. (3) It is easy to use, because the adaptive classification tree based matching strategy can give us fast and accurate initialization, even when the initial camera is different from the reference image to a large degree. Experimental evaluations validate the performance of the proposed method for online pose tracking and augmentation.
Smith, Zachary A.; Armin, Sean; Raphael, Dan; Khoo, Larry T.
2011-01-01
Background: We describe a new posterior dynamic stabilizing system that can be used to augment the mechanics of the degenerating lumbar segment. The mechanism of this system differs from other previously described surgical techniques that have been designed to augment lumbar biomechanics. The implant and technique we describe is an extension-limiting one, and it is designed to support and cushion the facet complex. Furthermore, it is inserted through an entirely percutaneous technique. The purpose of this technical note is to demonstrate a novel posterior surgical approach for the treatment of lumbar degenerative. Methods: This report describes a novel, percutaneously placed, posterior dynamic stabilization system as an alternative option to treat lumbar degenerative disk disease with and without lumbar spinal stenosis. The system does not require a midline soft-tissue dissection, nor subperiosteal dissection, and is a truly minimally invasive means for posterior augmentation of the functional facet complex. This system can be implanted as a stand-alone procedure or in conjunction with decompression procedures. Results: One-year clinical results in nine individual patients, all treated for degenerative disease of the lower lumbar spine, are presented. Conclusions: This novel technique allows for percutaneous posterior dynamic stabilization of the lumbar facet complex. The use of this procedure may allow a less invasive alternative to traditional approaches to the lumbar spine as well as an alternative to other newly developed posterior dynamic stabilization systems. PMID:22145084
Comparative evaluation of monocular augmented-reality display for surgical microscopes.
Rodriguez Palma, Santiago; Becker, Brian C; Lobes, Louis A; Riviere, Cameron N
2012-01-01
Medical augmented reality has undergone much development recently. However, there is a lack of studies quantitatively comparing the different display options available. This paper compares the effects of different graphical overlay systems in a simple micromanipulation task with "soft" visual servoing. We compared positioning accuracy in a real-time visually-guided task using Micron, an active handheld tremor-canceling microsurgical instrument, using three different displays: 2D screen, 3D screen, and microscope with monocular image injection. Tested with novices and an experienced vitreoretinal surgeon, display of virtual cues in the microscope via an augmented reality injection system significantly decreased 3D error (p < 0.05) compared to the 2D and 3D monitors when confounding factors such as magnification level were normalized.
Vision-based augmented reality system
NASA Astrophysics Data System (ADS)
Chen, Jing; Wang, Yongtian; Shi, Qi; Yan, Dayuan
2003-04-01
The most promising aspect of augmented reality lies in its ability to integrate the virtual world of the computer with the real world of the user. Namely, users can interact with the real world subjects and objects directly. This paper presents an experimental augmented reality system with a video see-through head-mounted device to display visual objects, as if they were lying on the table together with real objects. In order to overlay virtual objects on the real world at the right position and orientation, the accurate calibration and registration are most important. A vision-based method is used to estimate CCD external parameters by tracking 4 known points with different colors. It achieves sufficient accuracy for non-critical applications such as gaming, annotation and so on.
Validation of a Malay Version of the Smartphone Addiction Scale among Medical Students in Malaysia.
Ching, Siew Mooi; Yee, Anne; Ramachandran, Vasudevan; Sazlly Lim, Sazlyna Mohd; Wan Sulaiman, Wan Aliaa; Foo, Yoke Loong; Hoo, Fan Kee
2015-01-01
This study was initiated to determine the psychometric properties of the Smart Phone Addiction Scale (SAS) by translating and validating this scale into the Malay language (SAS-M), which is the main language spoken in Malaysia. This study can distinguish smart phone and internet addiction among multi-ethnic Malaysian medical students. In addition, the reliability and validity of the SAS was also demonstrated. A total of 228 participants were selected between August 2014 and September 2014 to complete a set of questionnaires, including the SAS and the modified Kimberly Young Internet addiction test (IAT) in the Malay language. There were 99 males and 129 females with ages ranging from 19 to 22 years old (21.7±1.1) included in this study. Descriptive and factor analyses, intra-class coefficients, t-tests and correlation analyses were conducted to verify the reliability and validity of the SAS. Bartlett's test of sphericity was significant (p <0.01), and the Kaiser-Mayer-Olkin measure of sampling adequacy for the SAS-M was 0.92, indicating meritoriously that the factor analysis was appropriate. The internal consistency and concurrent validity of the SAS-M were verified (Cronbach's alpha = 0.94). All of the subscales of the SAS-M, except for positive anticipation, were significantly related to the Malay version of the IAT. This study developed the first smart phone addiction scale among medical students. This scale was shown to be reliable and valid in the Malay language.
Preliminary Assessment of Thrust Augmentation of NEP Based Missions
NASA Technical Reports Server (NTRS)
Chew, Gilbert; Pelaccio, Dennis G.; Chiroux, Robert; Pervan, Sherry; Rauwolf, Gerald A.; White, Charles
2005-01-01
Science Applications International Corporation (SAIC), with support from NASA Marshall Space Flight Center, has conducted a preliminary study to compare options for augmenting the thrust of a conventional nuclear electric propulsion (NEP) system. These options include a novel nuclear propulsion system concept known as Hybrid Indirect Nuclear Propulsion (HINP) and conventional chemical propulsion. The utility and technical feasibility of the HINP concept are assessed, and features and potential of this new in-space propulsion system concept are identified. As part of the study, SAIC developed top-level design tools to model the size and performance of an HINP system, as well as for several chemical propulsion options, including liquid and gelled propellants. A mission trade study was performed to compare a representative HINP system with chemical propulsion options for thrust augmentation of NEP systems for a mission to Saturn's moon Titan. Details pertaining to the approach, features, initial demonstration results for HINP model development, and the mission trade study are presented. Key technology and design issues associated with the HINP concept and future work recommendations are also identified.
DMS augmented monitoring and diganosis application (DMS AMDA) prototype
NASA Technical Reports Server (NTRS)
Patterson-Hine, F. A.; Boyd, Mark A.; Iverson, David L.; Donnell, Brian; Lauritsen, Janet; Doubek, Sharon; Gibson, Jim; Monahan, Christine; Rosenthal, Donald A.
1993-01-01
The Data Management System Augmented Monitoring and Diagnosis Application (DMS AMDA) is currently under development at NASA Ames Research Center (ARC). It will provide automated monitoring and diagnosis capabilities for the Space Station Freedom (SSF) Data Management System (DMS) in the Control Center Complex (CCC) at NASA Johnson Space Center. Several advanced automation applications are under development for use in the CCC for other SSF subsystems. The DMS AMDA, however, is the first application to utilize digraph failure analysis techniques and the Extended Realtime FEAT (ERF) application as the core of its diagnostic system design, since the other projects were begun before the digraph tools were available. Model-based diagnosis and expert systems techniques will provide additional capabilities and augment ERF where appropriate. Utilization of system knowledge captured in the design phase of a system in digraphs should result in both a cost savings and a technical advantage during implementation of the diagnostic software. This paper addresses both the programmatic and technical considerations of this approach, and describes the software design and initial prototyping effort.
Kim, Ji-Min; Sohn, Dong-Seok; Heo, Jeong-Uk; Park, Jun-Sub; Jung, Heui-Seung; Moon, Jee-Won; Lee, Ju-Hyoung; Park, In-Sook
2012-12-01
The purpose of this study was to evaluate the success rate of implants and vertical bone gain of edentulous posterior maxilla using ultrasonic piezoelectric vibration and hydraulic pressure, namely the hydrodynamic piezoelectric internal sinus elevation (HPISE) technique through a crestal approach. A total of 250 maxillary sinuses were augmented using HPISE and 353 implants (averaging 11.8 mm in length and 4.5 mm in diameter), with 12 different systems, were placed simultaneously with or without additional bone grafting. Plain radiograms and cone beam computed tomograms were taken in all patients to evaluate sinus augmentation. Membrane perforation was recorded at 10 of the 353 implant sites. The perforation rate was 2.83%. The total success rate of implantation was 97.2% after an average of 69.3 weeks of loading. The crestally approached sinus augmentation using ultrasonic piezoelectric vibration and hydraulic pressure is an additional method of maxillary sinus augmentation.
Augmented Virtual Reality: How to Improve Education Systems
ERIC Educational Resources Information Center
Fernandez, Manuel
2017-01-01
This essay presents and discusses the developing role of virtual and augmented reality technologies in education. Addressing the challenges in adapting such technologies to focus on improving students' learning outcomes, the author discusses the inclusion of experiential modes as a vehicle for improving students' knowledge acquisition.…
Time Counts! Some Comments on System Latency in Head-Referenced Displays
NASA Technical Reports Server (NTRS)
Ellis, Stephen R.; Adelstein, Bernard D.
2013-01-01
System response latency is a prominent characteristic of human-computer interaction. Laggy systems are; however, not simply annoying but substantially reduce user productivity. The impact of latency on head referenced display systems, particularly head-mounted systems, is especially disturbing since not only can it interfere with dynamic registration in augmented reality displays but it also can in some cases indirectly contribute to motion sickness. We will summarize several experiments using standard psychophysical discrimination techniques that suggest what system latencies will be required to achieve perceptual stability for spatially referenced computer-generated imagery. In conclusion I will speculate about other system performance characteristics that I would hope to have for a dream augmented reality system.
D’Souza, Malcolm J.; Kashmar, Richard J.; Hurst, Kent; Fiedler, Frank; Gross, Catherine E.; Deol, Jasbir K.; Wilson, Alora
2015-01-01
Wesley College is a private, primarily undergraduate minority-serving institution located in the historic district of Dover, Delaware (DE). The College recently revised its baccalaureate biological chemistry program requirements to include a one-semester Physical Chemistry for the Life Sciences course and project-based experiential learning courses using instrumentation, data-collection, data-storage, statistical-modeling analysis, visualization, and computational techniques. In this revised curriculum, students begin with a traditional set of biology, chemistry, physics, and mathematics major core-requirements, a geographic information systems (GIS) course, a choice of an instrumental analysis course or a statistical analysis systems (SAS) programming course, and then, students can add major-electives that further add depth and value to their future post-graduate specialty areas. Open-sourced georeferenced census, health and health disparity data were coupled with GIS and SAS tools, in a public health surveillance system project, based on US county zip-codes, to develop use-cases for chronic adult obesity where income, poverty status, health insurance coverage, education, and age were categorical variables. Across the 48 contiguous states, obesity rates are found to be directly proportional to high poverty and inversely proportional to median income and educational achievement. For the State of Delaware, age and educational attainment were found to be limiting obesity risk-factors in its adult population. Furthermore, the 2004–2010 obesity trends showed that for two of the less densely populated Delaware counties; Sussex and Kent, the rates of adult obesity were found to be progressing at much higher proportions when compared to the national average. PMID:26191337
D'Souza, Malcolm J; Kashmar, Richard J; Hurst, Kent; Fiedler, Frank; Gross, Catherine E; Deol, Jasbir K; Wilson, Alora
Wesley College is a private, primarily undergraduate minority-serving institution located in the historic district of Dover, Delaware (DE). The College recently revised its baccalaureate biological chemistry program requirements to include a one-semester Physical Chemistry for the Life Sciences course and project-based experiential learning courses using instrumentation, data-collection, data-storage, statistical-modeling analysis, visualization, and computational techniques. In this revised curriculum, students begin with a traditional set of biology, chemistry, physics, and mathematics major core-requirements, a geographic information systems (GIS) course, a choice of an instrumental analysis course or a statistical analysis systems (SAS) programming course, and then, students can add major-electives that further add depth and value to their future post-graduate specialty areas. Open-sourced georeferenced census, health and health disparity data were coupled with GIS and SAS tools, in a public health surveillance system project, based on US county zip-codes, to develop use-cases for chronic adult obesity where income, poverty status, health insurance coverage, education, and age were categorical variables. Across the 48 contiguous states, obesity rates are found to be directly proportional to high poverty and inversely proportional to median income and educational achievement. For the State of Delaware, age and educational attainment were found to be limiting obesity risk-factors in its adult population. Furthermore, the 2004-2010 obesity trends showed that for two of the less densely populated Delaware counties; Sussex and Kent, the rates of adult obesity were found to be progressing at much higher proportions when compared to the national average.
The SAMS: Smartphone Addiction Management System and verification.
Lee, Heyoung; Ahn, Heejune; Choi, Samwook; Choi, Wanbok
2014-01-01
While the popularity of smartphones has given enormous convenience to our lives, their pathological use has created a new mental health concern among the community. Hence, intensive research is being conducted on the etiology and treatment of the condition. However, the traditional clinical approach based surveys and interviews has serious limitations: health professionals cannot perform continual assessment and intervention for the affected group and the subjectivity of assessment is questionable. To cope with these limitations, a comprehensive ICT (Information and Communications Technology) system called SAMS (Smartphone Addiction Management System) is developed for objective assessment and intervention. The SAMS system consists of an Android smartphone application and a web application server. The SAMS client monitors the user's application usage together with GPS location and Internet access location, and transmits the data to the SAMS server. The SAMS server stores the usage data and performs key statistical data analysis and usage intervention according to the clinicians' decision. To verify the reliability and efficacy of the developed system, a comparison study with survey-based screening with the K-SAS (Korean Smartphone Addiction Scale) as well as self-field trials is performed. The comparison study is done using usage data from 14 users who are 19 to 50 year old adults that left at least 1 week usage logs and completed the survey questionnaires. The field trial fully verified the accuracy of the time, location, and Internet access information in the usage measurement and the reliability of the system operation over more than 2 weeks. The comparison study showed that daily use count has a strong correlation with K-SAS scores, whereas daily use times do not strongly correlate for potentially addicted users. The correlation coefficients of count and times with total K-SAS score are CC = 0.62 and CC =0.07, respectively, and the t-test analysis for the contrast group of potential addicts and the values for the non-addicts were p = 0.047 and p = 0.507, respectively.
[Interactive augmented reality systems : Aid for personalized patient education and rehabilitation].
Bork, F
2018-04-01
During patient education, information exchange plays a critical role both for patient compliance during medical or rehabilitative treatment and for obtaining an informed consent for an operative procedure. In this article the augmented reality system "Magic Mirror" as an additive tool during patient education, rehabilitation as well as anatomical education is highlighted. The Magic Mirror system allows the user of the system to inspect both a detailed model of the 3‑dimensional anatomy of the human body and volumetric slice images in a virtual mirror environment. First preliminary results from the areas of rehabilitation and learning anatomy indicate the broad potential of the Magic Mirror. Similarly, the system also provides interesting advantages for patient education situations in comparison to traditional methods of information exchange. Novel technologies, such as augmented reality are a door opener for many innovations in medicine. In the future, patient-specific systems, such as the Magic Mirror will be used increasingly more in areas such as patient education and rehabilitation. In order to maximize the benefits of such systems, further evaluation studies are necessary to find out about the best use cases and to start an iterative optimization process of these systems.
The following SAS macros can be used to create a multivariate usual intake distribution for multiple dietary components that are consumed nearly every day or episodically. A SAS macro for performing balanced repeated replication (BRR) variance estimation is also included.
A SAS IML Macro for Loglinear Smoothing
ERIC Educational Resources Information Center
Moses, Tim; von Davier, Alina
2011-01-01
Polynomial loglinear models for one-, two-, and higher-way contingency tables have important applications to measurement and assessment. They are essentially regarded as a smoothing technique, which is commonly referred to as loglinear smoothing. A SAS IML (SAS Institute, 2002a) macro was created to implement loglinear smoothing according to…
PROC IRT: A SAS Procedure for Item Response Theory
Matlock Cole, Ki; Paek, Insu
2017-01-01
This article reviews the procedure for item response theory (PROC IRT) procedure in SAS/STAT 14.1 to conduct item response theory (IRT) analyses of dichotomous and polytomous datasets that are unidimensional or multidimensional. The review provides an overview of available features, including models, estimation procedures, interfacing, input, and output files. A small-scale simulation study evaluates the IRT model parameter recovery of the PROC IRT procedure. The use of the IRT procedure in Statistical Analysis Software (SAS) may be useful for researchers who frequently utilize SAS for analyses, research, and teaching.
De novo centriole formation in human cells is error-prone and does not require SAS-6 self-assembly.
Wang, Won-Jing; Acehan, Devrim; Kao, Chien-Han; Jane, Wann-Neng; Uryu, Kunihiro; Tsou, Meng-Fu Bryan
2015-11-26
Vertebrate centrioles normally propagate through duplication, but in the absence of preexisting centrioles, de novo synthesis can occur. Consistently, centriole formation is thought to strictly rely on self-assembly, involving self-oligomerization of the centriolar protein SAS-6. Here, through reconstitution of de novo synthesis in human cells, we surprisingly found that normal looking centrioles capable of duplication and ciliation can arise in the absence of SAS-6 self-oligomerization. Moreover, whereas canonically duplicated centrioles always form correctly, de novo centrioles are prone to structural errors, even in the presence of SAS-6 self-oligomerization. These results indicate that centriole biogenesis does not strictly depend on SAS-6 self-assembly, and may require preexisting centrioles to ensure structural accuracy, fundamentally deviating from the current paradigm.
Sugioka, Kenji; Hamill, Danielle R; Lowry, Joshua B; McNeely, Marie E; Enrick, Molly; Richter, Alyssa C; Kiebler, Lauren E; Priess, James R; Bowerman, Bruce
2017-01-01
The centriole/basal body is a eukaryotic organelle that plays essential roles in cell division and signaling. Among five known core centriole proteins, SPD-2/Cep192 is the first recruited to the site of daughter centriole formation and regulates the centriolar localization of the other components in C. elegans and in humans. However, the molecular basis for SPD-2 centriolar localization remains unknown. Here, we describe a new centriole component, the coiled-coil protein SAS-7, as a regulator of centriole duplication, assembly and elongation. Intriguingly, our genetic data suggest that SAS-7 is required for daughter centrioles to become competent for duplication, and for mother centrioles to maintain this competence. We also show that SAS-7 binds SPD-2 and regulates SPD-2 centriolar recruitment, while SAS-7 centriolar localization is SPD-2-independent. Furthermore, pericentriolar material (PCM) formation is abnormal in sas-7 mutants, and the PCM-dependent induction of cell polarity that defines the anterior-posterior body axis frequently fails. We conclude that SAS-7 functions at the earliest step in centriole duplication yet identified and plays important roles in the orchestration of centriole and PCM assembly. DOI: http://dx.doi.org/10.7554/eLife.20353.001 PMID:28092264
He, Jian; Zhao, Hangyuan; Li, Xiaolei; Su, Dong; Zhang, Fengrui; Ji, Huiming; Liu, Rui
2018-03-15
Bacterial cellulose aerogels/silica aerogels (BCAs/SAs) are prepared using three-dimensional self-assembled BC skeleton as reinforcement and methyltriethoxysilane derived silica aerogels as filler through vacuum infiltration and freeze drying. The BCAs/SAs possess a hierarchical cellular structure giving them superelasticity and recyclable compressibility. The BCAs/SAs can bear a compressive strain up to 80% and recover their original shapes after the release of the stress. The BCAs/SAs exhibit super-hydrophobicity with a contact angle of 152° and super-oleophilicity resulting from the methyl groups on the surface of silica aerogel filler. This endows the BCAs/SAs outstanding oil absorbing capability with the quality factor Q from 8 to 14 for organic solvents and oils. Moreover, the absorbed oil can be retrieved by mechanically squeezed with a recovery of 88% related to the superelastic ability of the composites. In addition, the oil absorbing of BS/SAs could be well maintained with the quality factor Q about 11 for gasoline after harsh conditional treatment down to -200 °C and up to 300 °C. Such outstanding elastic and oleophilic properties make the BC/SAs tremendous potential for applications of oil absorbing, recovery and oil-water separation. Copyright © 2017. Published by Elsevier B.V.
Sathigari, Sateesh Kumar; Ober, Courtney A; Sanganwar, Ganesh P; Gupta, Ram B; Babu, R Jayachandra
2011-07-01
Itraconazole (ITZ) microflakes were produced by supercritical antisolvent (SAS) method and simultaneously mixed with pharmaceutical excipients in a single step to prevent drug agglomeration. Simultaneous ITZ particle formation and mixing with fast-flo lactose (FFL) was performed in a high-pressure stirred vessel at 116 bar and 40 °C by the SAS-drug excipient mixing (SAS-DEM) method. The effects of stabilizers, such as sodium dodecyl sulfate and poloxamer 407 (PLX), on particle formation and drug dissolution were studied. Drug-excipient formulations were characterized for surface morphology, crystallinity, drug-excipient interactions, drug content uniformity, and drug dissolution rate. Mixture of drug microflakes and FFL formed by the SAS-DEM process shows that the process was successful in overcoming drug-drug agglomeration. PLX produced crystalline drug flakes in loose agglomerates with superior dissolution and flow properties even at higher drug loadings. Characterization studies confirmed the crystallinity of the drug and absence of chemical interactions during the SAS process. The dissolution of ITZ was substantially higher due to SAS and SAS-DEM processes; this improvement can be attributed to the microflake particle structures, effective deagglomeration, and wetting of the drug flakes with the excipients. Copyright © 2011 Wiley-Liss, Inc. and the American Pharmacists Association
NASA Astrophysics Data System (ADS)
Friesdorf, Florian; Pangercic, Dejan; Bubb, Heiner; Beetz, Michael
In mac, an ergonomic dialog-system and algorithms will be developed that enable human experts and companions to be integrated into knowledge gathering and decision making processes of highly complex cognitive systems (e.g. Assistive Household as manifested further in the paper). In this event we propose to join algorithms and methodologies coming from Ergonomics and Artificial Intelligence that: a) make cognitive systems more congenial for non-expert humans, b) facilitate their comprehension by utilizing a high-level expandable control code for human experts and c) augment representation of such cognitive system into “deep representation” obtained through an interaction with human companions.
High-brightness displays in integrated weapon sight systems
NASA Astrophysics Data System (ADS)
Edwards, Tim; Hogan, Tim
2014-06-01
In the past several years Kopin has demonstrated the ability to provide ultra-high brightness, low power display solutions in VGA, SVGA, SXGA and 2k x 2k display formats. This paper will review various approaches for integrating high brightness overlay displays with existing direct view rifle sights and augmenting their precision aiming and targeting capability. Examples of overlay display systems solutions will be presented and discussed. This paper will review significant capability enhancements that are possible when augmenting the real-world as seen through a rifle sight with other soldier system equipment including laser range finders, ballistic computers and sensor systems.
NASA Technical Reports Server (NTRS)
1982-01-01
The Current and Advanced Technology ACT control system definition tasks of the Integrated Application of Active Controls (IAAC) Technology project within the Energy Efficient Transport Program are summarized. The systems mechanize six active control functions: (1) pitch augmented stability; (2) angle of attack limiting; (3) lateral/directional augmented stability; (4) gust load alleviation; (5) maneuver load control; and (6) flutter mode control. The redundant digital control systems meet all function requirements with required reliability and declining weight and cost as advanced technology is introduced.
New approaches to evaluate sympathoadrenal system activity in experiments on Earth and in space
NASA Astrophysics Data System (ADS)
Kvetnansky, R.; Noskov, V. B.; Blazicek, P.; Macho, L.; Grigoriev, A. I.; Goldstein, D. S.; Kopin, I. J.
In previous studies the activity of the sympathoadrenal system (SAS) in cosmonauts during space flights was evaluated by measuring plasma catecholamines (CA) levels and urinary CA and their metabolites concentrations. Plasma CA levels are accepted indicators of SAS activity, however, they are determined by the plasma clearances as well as the rates of CA release (spillover-SO) into the bloodstream. Nowadays methods are available which evaluate not only plasma levels of CA but also their release, spillover, uptake, reuptake, degradation and also CA synthesis in vivo measured by plasma levels of dihydroxyphenylalanine (DOPA). Plasma concentrations of DOPA, the CA noradrenaline (NE), adrenaline (ADR), and dopamine (DA), the deaminated catechol metabolites dihydroxyphenylglycol (DHPG) and dihydroxyphenylacetic acid (DOPAC), and the O-methylated metabolites methoxyhydroxyphenylglycol (MHPG) and homovanillic acid (HVA) were measured during immobilization stress (IMO) in conscious rats. Radiotracer methods were used to measure NE SO. IMO markedly increased arterial NE levels but NE SO was less elevated bacause the NE clearance was slightly reduced in IMO rats. Simultaneous measurements of plasma CA and their metabolites provide another means to obtain information about SAS function. For instance, dissociation between changes of plasma DHPG and NE levels can indicate changes in neuronal reuptake of NE. We found marked parallel increases in plasma NE and DHPG levels during acute IMO; however after repeated IMO, plasma NE levels were increased but DHPG responses were less pronounced suggesting a reduced NE reuptake. DOPA, the CA precursor, circulates in plasma at a concentration higher than NE. During stress, increased sympathoneural outflow stimulates DOPA synthesis and release into the circulation supporting the view that changes in plasma DOPA levels during stress reflect in vivo changes in the rate of CA synthesis. We propose to measure the new plasma indicators of SAS activity in cosmonauts and/or in animals before, during and after space flights.
Game-Based Evacuation Drill Using Augmented Reality and Head-Mounted Display
ERIC Educational Resources Information Center
Kawai, Junya; Mitsuhara, Hiroyuki; Shishibori, Masami
2016-01-01
Purpose: Evacuation drills should be more realistic and interactive. Focusing on situational and audio-visual realities and scenario-based interactivity, the authors have developed a game-based evacuation drill (GBED) system that presents augmented reality (AR) materials on tablet computers. The paper's current research purpose is to improve…
Intelligent Augmented Reality Training for Motherboard Assembly
ERIC Educational Resources Information Center
Westerfield, Giles; Mitrovic, Antonija; Billinghurst, Mark
2015-01-01
We investigate the combination of Augmented Reality (AR) with Intelligent Tutoring Systems (ITS) to assist with training for manual assembly tasks. Our approach combines AR graphics with adaptive guidance from the ITS to provide a more effective learning experience. We have developed a modular software framework for intelligent AR training…
Examining Young Children's Perception toward Augmented Reality-Infused Dramatic Play
ERIC Educational Resources Information Center
Han, Jeonghye; Jo, Miheon; Hyun, Eunja; So, Hyo-jeong
2015-01-01
Amid the increasing interest in applying augmented reality (AR) in educational settings, this study explores the design and enactment of an AR-infused robot system to enhance children's satisfaction and sensory engagement with dramatic play activities. In particular, we conducted an exploratory study to empirically examine children's perceptions…
Design of ground test suspension systems for verification of flexible space structures
NASA Technical Reports Server (NTRS)
Cooley, V. M.; Juang, J. N.; Ghaemmaghami, P.
1988-01-01
A simple model demonstrates the frequency-increasing effects of a simple cable suspension on flexible test article/suspension systems. Two passive suspension designs, namely a negative spring mechanism and a rolling cart mechanism, are presented to alleviate the undesirable frequency-increasing effects. Analysis methods are provided for systems in which the augmentations are applied to both discrete and continuous representations of test articles. The damping analyses are based on friction equivalent viscous damping. Numerical examples are given for comparing the two augmentations with respect to minimizing frequency and damping increases.
Antibrowning and antimicrobial properties of sodium acid sulfate in apple slices.
Fan, Xuetong; Sokorai, Kimberly J B; Liao, Ching-Hsing; Cooke, Peter; Zhang, Howard Q
2009-01-01
There are few available compounds that can both control browning and enhance microbial safety of fresh-cut fruits. In the present study, the antibrowning ability of sodium acid sulfate (SAS) on "Granny Smith" apple slices was first investigated in terms of optimum concentration and treatment time. In a separate experiment, the apple slices were treated with water or 3% of SAS, calcium ascorbate, citric acid, or acidified calcium sulfate for 5 min. Total plate count, color, firmness, and tissue damage were assessed during a 21-d storage at 4 degrees C. Results showed that the efficacy of SAS in inhibiting browning of apple slices increased with increasing concentration. A minimum 3% of SAS was needed to achieve 14 d of shelf life. Firmness was not significantly affected by SAS at 3% or lower concentrations. Antibrowning potential of SAS was similar for all treatment times ranging from 2 to 10 min. However, SAS caused some skin discoloration of apple slices. When cut surface of apple slices were stained with a fluorescein diacetate solution, tissue damage could be observed under a microscope even though visual damage was not evident. Among the antibrowning agents tested, SAS was the most effective in inhibiting browning and microbial growth for the first 14 d. Total plate count of samples treated with 3% SAS was significantly lower than those treated with calcium ascorbate, a commonly used antibrowning agent. Our results suggested that it is possible to use SAS to control browning while inhibiting the growth of microorganisms on the apple slices if the skin damage can be minimized. Practical Application: Fresh-cut apples have emerged as one of the popular products in restaurants, schools, and food service establishments as more consumers demand fresh, convenient, and nutritious foods. Processing of fresh-cut apples induces mechanical damage to the fruit and exposes apple tissue to air, resulting in the development of undesirable tissue browning. The fresh-cut industry currently uses antibrowning agents to prevent discoloration. However, the antibrowning solutions can become contaminated with human pathogens such as Listeria monocytogenes, and washing of apple slices with the contaminated solutions can result in the transfer of pathogens to the product. It would be ideal if an antibrowning compound prevented the proliferation of human pathogens in solutions and minimized the growth of pathogens during storage. The study was conducted to investigate antibrowning and antimicrobial properties of sodium acid sulfate (SAS) in comparison with other common antibrowning agents on Granny Smith apples. Results showed that among the antimicrobial agents we tested, SAS was the most effective in inhibiting browning and microbial growth for 14 d at 4 degrees C. However, SAS caused some skin discoloration of apple slices. Overall, SAS can potentially be used to inhibit tissue browning while reducing the microbial growth on apple slices. The information is useful for the fresh-cut produce industry to enhance microbial safety of fresh-cut apples while minimizing browning, thus increasing the consumption of the health benefiting fresh fruit.
Ohnishi, Yuichi; Yasui, Hiroki; Kakudo, Kenji; Nozaki, Masami
2016-11-01
Lapatinib, a dual inhibitor of epidermal growth factor receptor (EGFR)/ErbB2, has antiproliferative effects and is used to treat patients with ErbB2-positive metastatic breast cancer. In the present study, we examined the effects of lapatinib on growth of oral and prostate cancer cells. Oral squamous cell carcinoma (OSCC) cell lines HSC3, HSC4 and Ca9-22 were sensitive to the antiproliferative effects of lapatinib in anchorage-dependent culture, but the OSCC cell lines KB and SAS and the prostate cancer cell line DU145 were resistant to lapatinib. Phosphorylation levels of EGFR in all cell lines decreased during lapatinib treatment in anchorage‑dependent culture. Furthermore, the phosphorylation levels of ErbB2, ErbB3 and Akt and the protein levels of cyclin D1 were decreased by lapatinib treatment of HSC3, HSC4 and Ca9-22 cells. ErbB3 was not expressed and cyclin D1 protein levels were not altered by lapatinib treatment in KB, DU145 and SAS cells. The phosphorylation of ErbB2 and AKT was not affected by lapatinib in SAS cells and was not detected in KB and DU145 cells. Lapatinib-resistant cell lines exhibited sphere-forming ability, and SAS cells developed sensitivity to lapatinib during sphere formation. The phosphorylation levels of ErbB2 and AKT and protein levels of cyclin D2 increased during sphere formation of SAS cells and decreased with lapatinib treatment. In addition, sphere formation of SAS cells was inhibited by the AKT inhibitor MK2206. AKT phosphorylation and cyclin D2 levels in SAS spheres were decreased by MK2206 treatment. SAS cells expressed E-cadherin, but not vimentin and KB cells expressed vimentin, but not E-cadherin. DU145 cells expressed vimentin and E-cadherin. These results suggested that phosphorylation of EGFR and ErbB2 by cell detachment from the substratum induces the AKT pathway/cyclin D2-dependent sphere growth in SAS epithelial cancer stem-like cells, thereby rendering SAS spheres sensitive to lapatinib treatment.
NASA Technical Reports Server (NTRS)
1948-01-01
The conference on Turbojet-Engine Thrust-Augmentation Research was organized by the NACA to present in summarized form the results of the latest experimental and analytical investigations conducted at the Lewis Flight Propulsion Laboratory on methods of augmenting the thrust of turbojet engines. The technical discussions are reproduced herewith in the same form in which they were presented. The original presentation in this record are considered as complementary to, rather than substitutes for, the committee's system of complete and formal reports.
Validation of a Malay Version of the Smartphone Addiction Scale among Medical Students in Malaysia
Sazlly Lim, Sazlyna Mohd; Wan Sulaiman, Wan Aliaa; Foo, Yoke Loong; Hoo, Fan kee
2015-01-01
Introduction This study was initiated to determine the psychometric properties of the Smart Phone Addiction Scale (SAS) by translating and validating this scale into the Malay language (SAS-M), which is the main language spoken in Malaysia. This study can distinguish smart phone and internet addiction among multi-ethnic Malaysian medical students. In addition, the reliability and validity of the SAS was also demonstrated. Materials and Methods A total of 228 participants were selected between August 2014 and September 2014 to complete a set of questionnaires, including the SAS and the modified Kimberly Young Internet addiction test (IAT) in the Malay language. Results There were 99 males and 129 females with ages ranging from 19 to 22 years old (21.7±1.1) included in this study. Descriptive and factor analyses, intra-class coefficients, t-tests and correlation analyses were conducted to verify the reliability and validity of the SAS. Bartlett’s test of sphericity was significant (p <0.01), and the Kaiser-Mayer-Olkin measure of sampling adequacy for the SAS-M was 0.92, indicating meritoriously that the factor analysis was appropriate. The internal consistency and concurrent validity of the SAS-M were verified (Cronbach’s alpha = 0.94). All of the subscales of the SAS-M, except for positive anticipation, were significantly related to the Malay version of the IAT. Conclusions This study developed the first smart phone addiction scale among medical students. This scale was shown to be reliable and valid in the Malay language. PMID:26431511
Weathers, Trenna; Unni, Elizabeth
2018-04-01
Objective. To assess the level of publication rates from 2011 through 2015 by Social and Administrative Sciences (SAS) faculty at non-research intensive pharmacy schools. Methods. The Web of Science database was searched using faculty names identified from the American Association of Colleges of Pharmacy (AACP) faculty and professional staff roster. Publication rates of SAS faculty were calculated and compared using several demographic subcategories such as public/private school, part of an academic health center, schools with PhD program, funding status, etc. Results. The 208 SAS faculty members from 59 colleges contributed to 478 publications with a mean of 95.6 publications per year and 1.62 publications per institution per year. The number of publications increased 45% over the five years from 67 publications in 2011 to 122 in 2015.The average number of publications was 0.92 per year per SAS faculty compared to 0.82 publications per year per faculty from other basic pharmaceutical sciences divisions. The most commonly published research was research articles in the area of scholarship of teaching and learning. The significant predictors of publications were being part of an academic health center, having a PhD program, and higher percent of faculty members who are SAS faculty. Conclusion. Despite being affiliated with institutions with missions less targeted on research, this study showed SAS faculty members at non-research intensive institutions consistently contribute to published literature. Further studies are needed to examine reasons for the lack of publishing by almost half of the SAS faculty and ways to increase research and publication in the field of SAS.
Li, Yingjie; Qiao, Xianliang; Zhang, Ya-Nan; Zhou, Chengzhi; Xie, Huaijun; Chen, Jingwen
2016-10-01
The occurrence of sulfonamide antibiotics (SAs) in estuarine waters urges insights into their environmental fate for ecological risk assessment. Although many studies focused on the photochemical behavior of SAs, yet the effects of halide ions relevant to estuarine and marine environments on their photodegradation have been poorly understood. Here, we investigated the effects of halide ions on the photodegradation of SAs with sulfapyridine, sulfamethazine, and sulfamethoxazole as representative compounds. Results showed that halide ions did not significantly impact the photodegradation of sulfapyridine and sulfamethoxazole, while they significantly promoted the photodegradation of sulfamethazine. Further experiments found that ionic strength applied with NaClO4 significantly enhanced the photodegradation of the SAs, which was attributed to the decreased quenching rate constant of the triplet-excited SAs ((3)SA(∗)). Compared with ionic strength, specific Cl(-) effects retarded the photodegradation of the SAs. Our study found that triplet-excited sulfamethazine can oxidize halide ions to produce halogen radicals, subsequently leading to the halogenation of sulfamethazine, which was confirmed by the identification of both chlorinated and brominated intermediates. These results indicate that halide ions play an important role in the photochemical behavior of some SAs in estuarine waters and seawater. The occurrence of halogenation for certain organic pollutants can be predicted by comparing the oxidation potentials of triplet-excited contaminants with those of halogen radicals. Our findings are helpful in understanding the photochemical behavior and assessing the ecological risks of SAs and other organic pollutants in estuarine and marine environment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Personality disorders and suicide attempts in unipolar and bipolar mood disorders.
Jylhä, Pekka; Rosenström, Tom; Mantere, Outi; Suominen, Kirsi; Melartin, Tarja; Vuorilehto, Maria; Holma, Mikael; Riihimäki, Kirsi; Oquendo, Maria A; Keltikangas-Järvinen, Liisa; Isometsä, Erkki T
2016-01-15
Comorbid personality disorders may predispose patients with mood disorders to suicide attempts (SAs), but factors mediating this effect are not well known. Altogether 597 patients from three prospective cohort studies (Vantaa Depression Study, Jorvi Bipolar Study, and Vantaa Primary Care Depression Study) were interviewed at baseline, at 18 months, and in VDS and PC-VDS at 5 years. Personality disorders (PDs) at baseline, number of previous SAs, life-charted time spent in major depressive episodes (MDEs), and precise timing of SAs during follow-up were determined and investigated. Overall, 219 (36.7%) patients had a total of 718 lifetime SAs; 88 (14.7%) patients had 242 SAs during the prospective follow-up. Having any PD diagnosis increased the SA rate, both lifetime and prospectively evaluated, by 90% and 102%, respectively. All PD clusters increased the rate of new SAs, although cluster C PDs more than the others. After adjusting for time spent in MDEs, only cluster C further increased the SA rate (by 52%). Mediation analyses of PD effects on prospectively ascertained SAs indicated significant mediated effects through time at risk in MDEs, but also some direct effects. Findings generalizable only to patients with mood disorders. Among mood disorder patients, comorbid PDs increase the risk of SAs to approximately two-fold. The excess risk is mostly due to patients with comorbid PDs spending more time in depressive episodes than those without. Consequently, risk appears highest for PDs that most predispose to chronicity and recurrences. However, also direct risk-modifying effects of PDs exist. Copyright © 2015 Elsevier B.V. All rights reserved.
Stern, Joshua A; White, Stephen N; Lehmkuhl, Linda B; Reina-Doreste, Yamir; Ferguson, Jordan L; Nascone-Yoder, Nanette M; Meurs, Kathryn M
2014-09-01
Familial subvalvular aortic stenosis (SAS) is one of the most common congenital heart defects in dogs and is an inherited defect of Newfoundlands, golden retrievers and human children. Although SAS is known to be inherited, specific genes involved in Newfoundlands with SAS have not been defined. We hypothesized that SAS in Newfoundlands is inherited in an autosomal dominant pattern and caused by a single genetic variant. We studied 93 prospectively recruited Newfoundland dogs, and 180 control dogs of 30 breeds. By providing cardiac screening evaluations for Newfoundlands we conducted a pedigree evaluation, genome-wide association study and RNA sequence analysis to identify a proposed pattern of inheritance and genetic loci associated with the development of SAS. We identified a three-nucleotide exonic insertion in phosphatidylinositol-binding clathrin assembly protein (PICALM) that is associated with the development of SAS in Newfoundlands. Pedigree evaluation best supported an autosomal dominant pattern of inheritance and provided evidence that equivocally affected individuals may pass on SAS in their progeny. Immunohistochemistry demonstrated the presence of PICALM in the canine myocardium and area of the subvalvular ridge. Additionally, small molecule inhibition of clathrin-mediated endocytosis resulted in developmental abnormalities within the outflow tract (OFT) of Xenopus laevis embryos. The ability to test for presence of this PICALM insertion may impact dog-breeding decisions and facilitate reduction of SAS disease prevalence in Newfoundland dogs. Understanding the role of PICALM in OFT development may aid in future molecular and genetic investigations into other congenital heart defects of various species.
Divertor Coil Design and Implementation on Pegasus
NASA Astrophysics Data System (ADS)
Shriwise, P. C.; Bongard, M. W.; Cole, J. A.; Fonck, R. J.; Kujak-Ford, B. A.; Lewicki, B. T.; Winz, G. R.
2012-10-01
An upgraded divertor coil system is being commissioned on the Pegasus Toroidal Experiment in conjunction with power system upgrades in order to achieve higher β plasmas, reduce impurities, and possibly achieve H-mode operation. Design points for the divertor coil locations and estimates of their necessary current ratings were found using predictive equilibrium modeling based upon a 300 kA target plasma. This modeling represented existing Pegasus coil locations and current drive limits. The resultant design calls for 125 kA-turns from the divertor system to support the creation of a double null magnetic topology in plasmas with Ip<=300 kA. Initial experiments using this system will employ 900 V IGBT power supply modules to provide IDIV<=4 kA. The resulting 20 kA-turn capability of the existing divertor coil will be augmented by a new coil providing additional A-turns in series. Induced vessel wall current modeling indicates the time response of a 28 turn augmentation coil remains fast compared to the poloidal field penetration rate through the vessel. First results operating the augmented system are shown.
Zhou, Qi; Peng, Dapeng; Wang, Yulian; Pan, Yuanhu; Wan, Dan; Zhang, Xiya; Yuan, Zonghui
2014-07-01
For high-throughput monitoring of the residues of sulfonamides (SAs) in edible animal tissues, a novel hapten and monoclonal-based indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was developed. The novel hapten was synthesized and conjugated to carrier protein as immunogen. The spleen cells of the inoculated mice expressing group-specificity against SAs were fused. The obtained monoclonal antibody 4E5 showed the cross-reactivity (CR) to 16 structurally different SAs. Based on this antibody, an optimised icELISA protocol was carried out with only phosphate-buffered saline for the fast extraction of SAs in the tissues. The limits of detection of SAs in chicken ranged from 1.5 to 22.3μgkg(-1). The recoveries were 70.6-121% with less than 24.1% relative standard deviation. The developed ic-ELISA showed a good correlation with high performance liquid chromatography. It would be a useful tool for the screening of residues of SAs in edible animal tissues. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chen, Vivian Yi-Ju; Yang, Tse-Chuan
2012-08-01
An increasing interest in exploring spatial non-stationarity has generated several specialized analytic software programs; however, few of these programs can be integrated natively into a well-developed statistical environment such as SAS. We not only developed a set of SAS macro programs to fill this gap, but also expanded the geographically weighted generalized linear modeling (GWGLM) by integrating the strengths of SAS into the GWGLM framework. Three features distinguish our work. First, the macro programs of this study provide more kernel weighting functions than the existing programs. Second, with our codes the users are able to better specify the bandwidth selection process compared to the capabilities of existing programs. Third, the development of the macro programs is fully embedded in the SAS environment, providing great potential for future exploration of complicated spatially varying coefficient models in other disciplines. We provided three empirical examples to illustrate the use of the SAS macro programs and demonstrated the advantages explained above. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Cottee, Matthew A; Muschalik, Nadine; Johnson, Steven; Leveson, Joanna; Raff, Jordan W; Lea, Susan M
2015-01-01
Sas-6 and Ana2/STIL proteins are required for centriole duplication and the homo-oligomerisation properties of Sas-6 help establish the ninefold symmetry of the central cartwheel that initiates centriole assembly. Ana2/STIL proteins are poorly conserved, but they all contain a predicted Central Coiled-Coil Domain (CCCD). Here we show that the Drosophila Ana2 CCCD forms a tetramer, and we solve its structure to 0.8 Å, revealing that it adopts an unusual parallel-coil topology. We also solve the structure of the Drosophila Sas-6 N-terminal domain to 2.9 Å revealing that it forms higher-order oligomers through canonical interactions. Point mutations that perturb Sas-6 or Ana2 homo-oligomerisation in vitro strongly perturb centriole assembly in vivo. Thus, efficient centriole duplication in flies requires the homo-oligomerisation of both Sas-6 and Ana2, and the Ana2 CCCD tetramer structure provides important information on how these proteins might cooperate to form a cartwheel structure. DOI: http://dx.doi.org/10.7554/eLife.07236.001 PMID:26002084
Li, Xiaohui; Wu, Kan; Sun, Zhipei; Meng, Bo; Wang, Yonggang; Wang, Yishan; Yu, Xuechao; Yu, Xia; Zhang, Ying; Shum, Perry Ping; Wang, Qi Jie
2016-01-01
Low phase noise mode-locked fiber laser finds important applications in telecommunication, ultrafast sciences, material science, and biology, etc. In this paper, two types of carbon nano-materials, i.e. single-wall carbon nanotube (SWNT) and graphene oxide (GO), are investigated as efficient saturable absorbers (SAs) to achieve low phase noise mode-locked fiber lasers. Various properties of these wall-paper SAs, such as saturable intensity, optical absorption and degree of purity, are found to be key factors determining the performance of the ultrafast pulses. Reduced-noise femtosecond fiber lasers based on such carbon-based SAs are experimentally demonstrated, for which the phase noise has been reduced by more than 10 dB for SWNT SAs and 8 dB for GO SAs at 10 kHz. To the best of our knowledge, this is the first investigation on the relationship between different carbon material based SAs and the phase noise of mode-locked lasers. This work paves the way to generate high-quality low phase noise ultrashort pulses in passively mode-locked fiber lasers. PMID:27126900
2010-05-01
decontaminate chemical and biological agents from sensitive equipment (avionics, electronics, electrical , and environmental systems and equipment...fabricated 2 x 2 in. square, 3/32 in. thick aluminum shims, augmented with electrical tape for added thickness as needed, were used in these tests to make...test coupons, thin custom-fabricated 2x2 in. square x 3/32 in. thick aluminum shims, augmented with electrical tape for added thickness as needed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ionescu-Bujor, Mihaela; Jin Xuezhou; Cacuci, Dan G.
2005-09-15
The adjoint sensitivity analysis procedure for augmented systems for application to the RELAP5/MOD3.2 code system is illustrated. Specifically, the adjoint sensitivity model corresponding to the heat structure models in RELAP5/MOD3.2 is derived and subsequently augmented to the two-fluid adjoint sensitivity model (ASM-REL/TF). The end product, called ASM-REL/TFH, comprises the complete adjoint sensitivity model for the coupled fluid dynamics/heat structure packages of the large-scale simulation code RELAP5/MOD3.2. The ASM-REL/TFH model is validated by computing sensitivities to the initial conditions for various time-dependent temperatures in the test bundle of the Quench-04 reactor safety experiment. This experiment simulates the reflooding with water ofmore » uncovered, degraded fuel rods, clad with material (Zircaloy-4) that has the same composition and size as that used in typical pressurized water reactors. The most important response for the Quench-04 experiment is the time evolution of the cladding temperature of heated fuel rods. The ASM-REL/TFH model is subsequently used to perform an illustrative sensitivity analysis of this and other time-dependent temperatures within the bundle. The results computed by using the augmented adjoint sensitivity system, ASM-REL/TFH, highlight the reliability, efficiency, and usefulness of the adjoint sensitivity analysis procedure for computing time-dependent sensitivities.« less
Guo, Dongchuan; Wu, Yun; Kaplan, Heidi B.
2000-01-01
Starvation and cell density regulate the developmental expression of Myxococcus xanthus gene 4521. Three classes of mutants allow expression of this developmental gene during growth on nutrient agar, such that colonies of strains containing a Tn5 lac Ω4521 fusion are Lac+. One class of these mutants inactivates SasN, a negative regulator of 4521 expression; another class activates SasS, a sensor kinase-positive regulator of 4521 expression; and a third class blocks lipopolysaccharide (LPS) O-antigen biosynthesis. To identify additional positive regulators of 4521 expression, 11 Lac− TnV.AS transposon insertion mutants were isolated from a screen of 18,000 Lac+ LPS O-antigen mutants containing Tn5 lac Ω4521 (Tcr). Ten mutations identified genes that could encode positive regulators of 4521 developmental expression based on their ability to abolish 4521 expression during development in the absence of LPS O antigen and in an otherwise wild-type background. Eight of these mutations mapped to the sasB locus, which encodes the known 4521 regulators SasS and SasN. One mapped to sasS, whereas seven identified new genes. Three mutations mapped to a gene encoding an NtrC-like response regulator homologue, designated sasR, and four others mapped to a gene designated sasP. One mutation, designated ssp10, specifically suppressed the LPS O-antigen defect; the ssp10 mutation had no effect on 4521 expression in an otherwise wild-type background but reduced 4521 developmental expression in the absence of LPS O antigen to a level close to that of the parent strain. All of the mutations except those in sasP conferred defects during growth and development. These data indicate that a number of elements are required for 4521 developmental expression and that most of these are necessary for normal growth and fruiting body development. PMID:10913090
Pallaskorpi, Sanna; Suominen, Kirsi; Ketokivi, Mikko; Valtonen, Hanna; Arvilommi, Petri; Mantere, Outi; Leppämäki, Sami; Isometsä, Erkki
2017-02-01
Few long-term studies on bipolar disorder (BD) have investigated the incidence and risk factors of suicide attempts (SAs) specifically related to illness phases. We examined the incidence of SAs during different phases of BD in a long-term prospective cohort of bipolar I (BD-I) and bipolar II (BD-II) patients, and risk factors specifically for SAs during major depressive episodes (MDEs). In the Jorvi Bipolar Study (JoBS), 191 BD-I and BD-II patients were followed using life-chart methodology. Prospective information on SAs of 177 patients (92.7%) during different illness phases was available up to 5 years. The incidence of SAs and their predictors were investigated using logistic and Poisson regression models. Analyses of risk factors for SAs occurring during MDEs were conducted using two-level random-intercept logistic regression models. During the 5 years of follow-up, 90 SAs per 718 patient-years occurred. The incidence was highest, over 120-fold higher than in euthymia, during mixed states (765/1000 person-years; 95% confidence interval [CI] 461-1269 person-years), and also very high in MDEs, almost 60-fold higher than in euthymia (354/1000 person-years; 95% CI 277-451 person-years). For risk of SAs during MDEs, the duration of MDEs, severity of depression, and cluster C personality disorders were significant predictors. We confirmed in this long-term study that the highest incidences of SAs occur in mixed and major depressive illness phases. The variations in incidence rates between euthymia and illness phases were remarkably large, suggesting that the question "when" rather than "who" may be more relevant for suicide risk in BD. However, risk during MDEs is likely also influenced by personality factors. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cabrilo, Ivan; Bijlenga, Philippe; Schaller, Karl
2014-09-01
Augmented reality technology has been used for intraoperative image guidance through the overlay of virtual images, from preoperative imaging studies, onto the real-world surgical field. Although setups based on augmented reality have been used for various neurosurgical pathologies, very few cases have been reported for the surgery of arteriovenous malformations (AVM). We present our experience with AVM surgery using a system designed for image injection of virtual images into the operating microscope's eyepiece, and discuss why augmented reality may be less appealing in this form of surgery. N = 5 patients underwent AVM resection assisted by augmented reality. Virtual three-dimensional models of patients' heads, skulls, AVM nidi, and feeder and drainage vessels were selectively segmented and injected into the microscope's eyepiece for intraoperative image guidance, and their usefulness was assessed in each case. Although the setup helped in performing tailored craniotomies, in guiding dissection and in localizing drainage veins, it did not provide the surgeon with useful information concerning feeder arteries, due to the complexity of AVM angioarchitecture. The difficulty in intraoperatively conveying useful information on feeder vessels may make augmented reality a less engaging tool in this form of surgery, and might explain its underrepresentation in the literature. Integrating an AVM's hemodynamic characteristics into the augmented rendering could make it more suited to AVM surgery.
Progress of studies on preparation of TiO2 photocatalysts with sol-gel auto igniting synthesis
NASA Astrophysics Data System (ADS)
Wu, Di; Shi, Zaifeng; Zhang, Xiaopeng; Xinghui, Wu
2017-11-01
In this article, influencing factors on the kinetics of the process of Sol-gel Auto igniting Synthesis (SAS) which is an advanced technology for preparing nanometer particles of inorganic materials were reviewed. The studies on preparing of nanometer TiO2 photocatalysts with SAS were focused. It was concluded that SAS will play an important role in practical preparing of high-pure nanometer TiO2 powder, and as a technical support, preparation of titania TiO2 from titanic iron ore with SAS is feasible and practicable.
C-A1-03: Considerations in the Design and Use of an Oracle-based Virtual Data Warehouse
Bredfeldt, Christine; McFarland, Lela
2011-01-01
Background/Aims The amount of clinical data available for research is growing exponentially. As it grows, increasing the efficiency of both data storage and data access becomes critical. Relational database management systems (rDBMS) such as Oracle are ideal solutions for managing longitudinal clinical data because they support large-scale data storage and highly efficient data retrieval. In addition, they can greatly simplify the management of large data warehouses, including security management and regular data refreshes. However, the HMORN Virtual Data Warehouse (VDW) was originally designed based on SAS datasets, and this design choice has a number of implications for both the design and use of an Oracle-based VDW. From a design standpoint, VDW tables are designed as flat SAS datasets, which do not take full advantage of Oracle indexing capabilities. From a data retrieval standpoint, standard VDW SAS scripts do not take advantage of SAS pass-through SQL capabilities to enable Oracle to perform the processing required to narrow datasets to the population of interest. Methods Beginning in 2009, the research department at Kaiser Permanente in the Mid-Atlantic States (KPMA) has developed an Oracle-based VDW according to the HMORN v3 specifications. In order to take advantage of the strengths of relational databases, KPMA introduced an interface layer to the VDW data, using views to provide access to standardized VDW variables. In addition, KPMA has developed SAS programs that provide access to SQL pass-through processing for first-pass data extraction into SAS VDW datasets for processing by standard VDW scripts. Results We discuss both the design and performance considerations specific to the KPMA Oracle-based VDW. We benchmarked performance of the Oracle-based VDW using both standard VDW scripts and an initial pre-processing layer to evaluate speed and accuracy of data return. Conclusions Adapting the VDW for deployment in an Oracle environment required minor changes to the underlying structure of the data. Further modifications of the underlying data structure would lead to performance enhancements. Maximally efficient data access for standard VDW scripts requires an extra step that involves restricting the data to the population of interest at the data server level prior to standard processing.
The FY 1979 Department of Defense Program for Research, Development, and Acquisition
1978-02-01
in mobile SA~s, diversity. -- U.S. leads in look-down/shoot-down interceptor technology. -- USSR is making a substantial effort to advance ABM ...penetrate advanced SAM and ABM systems without loss of the overall system accuracy now achievable only with ballistic reentry systems. Later AMaRV...not witnessed a corresponding decrease in the level of Soviet BMD activity. In addition to continuing the operation of their Moscow ABM System, the
Mogl, Martina T; Nüssler, Natascha C; Presser, Sabine J; Podrabsky, Petr; Denecke, Timm; Grieser, Christian; Neuhaus, Peter; Guckelberger, Olaf
2010-08-01
Impaired hepatic arterial perfusion after orthotopic liver transplantation (OLT) may lead to ischemic biliary tract lesions and graft-loss. Hampered hepatic arterial blood flow is observed in patients with hypersplenism, often described as arterial steal syndrome (ASS). However, arterial and portal perfusions are directly linked via the hepatic arterial buffer response (HABR). Recently, the term 'splenic artery syndrome' (SAS) was coined to describe the effect of portal hyperperfusion leading to diminished hepatic arterial blood flow. We retrospectively analyzed 650 transplantations in 585 patients. According to preoperative imaging, 78 patients underwent prophylactic intraoperative ligation of the splenic artery. In case of postoperative SAS, coil-embolization of the splenic artery was performed. After exclusion of 14 2nd and 3rd retransplantations and 83 procedures with arterial interposition grafts, SAS was diagnosed in 28 of 553 transplantations (5.1%). Twenty-six patients were treated with coil-embolization, leading to improved liver function, but requiring postinterventional splenectomy in two patients. Additionally, two patients with SAS underwent splenectomy or retransplantation without preceding embolization. Prophylactic ligation could not prevent SAS entirely (n = 2), but resulted in a significantly lower rate of complications than postoperative coil-embolization. We recommend prophylactic ligation of the splenic artery for patients at risk of developing SAS. Post-transplant coil-embolization of the splenic artery corrected hemodynamic changes of SAS, but was associated with a significant morbidity.
Park, Junsung; Park, Hee Jun; Cho, Wonkyung; Cha, Kwang-Ho; Kang, Young-Shin; Hwang, Sung-Joo
2010-08-30
The aim of this study was to investigate the effects of micronization and amorphorization of cefdinir on solubility and dissolution rate. The amorphous samples were prepared by spray-drying (SD) and supercritical anti-solvent (SAS) process, respectively and their amorphous natures were confirmed by DSC, PXRD and FT-IR. Thermal gravimetric analysis was performed by TGA. SEM was used to investigate the morphology of particles and the processed particle had a spherical shape, while the unprocessed crystalline particle had a needle-like shape. The mean particle size and specific surface area were measured by dynamic light scattering (DLS) and BET, respectively. The DLS result showed that the SAS-processed particle was the smallest, followed by SD and the unprocessed cefdinir. The BET result was the same as DLS result in that the SAS-processed particle had the largest surface area. Therefore, the processed cefdinir, especially the SAS-processed particle, appeared to have enhanced apparent solubility, improved intrinsic dissolution rate and better drug release when compared with SD-processed and unprocessed crystalline cefdinir due not only to its amorphous nature, but also its reduced particle size. Conclusions were that the solubility and dissolution rate of crystalline cefdinir could be improved by physically modifying the particles using SD and SAS-process. Furthermore, SAS-process was a powerful methodology for improving the solubility and dissolution rate of cefdinir. Copyright 2010 Elsevier B.V. All rights reserved.
Advanced Visual and Instruction Systems for Maintenance Support (AVIS-MS)
2006-12-01
Hayashi , "Augmentable Reality: Situated Communication through Physical and Digital Spaces," Proc. 2nd Int’l Symp. Wearable Computers, IEEE CS Press...H. Ohno , "An Optical See-through Display for Mutual Occlusion of Real and Virtual Environments," Proc. Int’l Symp. Augmented Reality 2000 (ISARO0
Volumetric, dashboard-mounted augmented display
NASA Astrophysics Data System (ADS)
Kessler, David; Grabowski, Christopher
2017-11-01
The optical design of a compact volumetric display for drivers is presented. The system displays a true volume image with realistic physical depth cues, such as focal accommodation, parallax and convergence. A large eyebox is achieved with a pupil expander. The windshield is used as the augmented reality combiner. A freeform windshield corrector is placed at the dashboard.
NASA Technical Reports Server (NTRS)
Gregory, Irene M.; Gadient, ROss; Lavretsky, Eugene
2011-01-01
This paper presents flight test results of a robust linear baseline controller with and without composite adaptive control augmentation. The flight testing was conducted using the NASA Generic Transport Model as part of the Airborne Subscale Transport Aircraft Research system at NASA Langley Research Center.
Integrated Authoring Tool for Mobile Augmented Reality-Based E-Learning Applications
ERIC Educational Resources Information Center
Lobo, Marcos Fermin; Álvarez García, Víctor Manuel; del Puerto Paule Ruiz, María
2013-01-01
Learning management systems are increasingly being used to complement classroom teaching and learning and in some instances even replace traditional classroom settings with online educational tools. Mobile augmented reality is an innovative trend in e-learning that is creating new opportunities for teaching and learning. This article proposes a…
Using Augmented Reality Tools to Enhance Children's Library Services
ERIC Educational Resources Information Center
Meredith, Tamara R.
2015-01-01
Augmented reality (AR) has been used and documented for a variety of commercial and educational purposes, and the proliferation of mobile devices has increased the average person's access to AR systems and tools. However, little research has been done in the area of using AR to supplement traditional library services, specifically for patrons aged…
The Design of Immersive English Learning Environment Using Augmented Reality
ERIC Educational Resources Information Center
Li, Kuo-Chen; Chen, Cheng-Ting; Cheng, Shein-Yung; Tsai, Chung-Wei
2016-01-01
The study uses augmented reality (AR) technology to integrate virtual objects into the real learning environment for language learning. The English AR classroom is constructed using the system prototyping method and evaluated by semi-structured in-depth interviews. According to the flow theory by Csikszenmihalyi in 1975 along with the immersive…
Review of Augmented Paper Systems in Education: An Orchestration Perspective
ERIC Educational Resources Information Center
Prieto, Luis P.; Wen, Yun; Caballero, Daniela; Dillenbourg, Pierre
2014-01-01
Augmented paper has been proposed as a way to integrate more easily ICTs in settings like formal education, where paper has a strong presence. However, despite the multiplicity of educational applications using paper-based computing, their deployment in authentic settings is still marginal. To better understand this gap between research proposals…
ERIC Educational Resources Information Center
Coston, Caroline A., Ed.
The document consists of 30 author contributed chapters concerned with augmentative communication service delivery. Chapter titles and authors are: "Communication Options for Persons Who Cannot Speak: Planning for Service Delivery" (David Beukelman); "Planning Service Delivery Systems" (Roland Hahn II); "Planning Ohio's…
CNN-SVM for Microvascular Morphological Type Recognition with Data Augmentation.
Xue, Di-Xiu; Zhang, Rong; Feng, Hui; Wang, Ya-Lei
2016-01-01
This paper focuses on the problem of feature extraction and the classification of microvascular morphological types to aid esophageal cancer detection. We present a patch-based system with a hybrid SVM model with data augmentation for intraepithelial papillary capillary loop recognition. A greedy patch-generating algorithm and a specialized CNN named NBI-Net are designed to extract hierarchical features from patches. We investigate a series of data augmentation techniques to progressively improve the prediction invariance of image scaling and rotation. For classifier boosting, SVM is used as an alternative to softmax to enhance generalization ability. The effectiveness of CNN feature representation ability is discussed for a set of widely used CNN models, including AlexNet, VGG-16, and GoogLeNet. Experiments are conducted on the NBI-ME dataset. The recognition rate is up to 92.74% on the patch level with data augmentation and classifier boosting. The results show that the combined CNN-SVM model beats models of traditional features with SVM as well as the original CNN with softmax. The synthesis results indicate that our system is able to assist clinical diagnosis to a certain extent.
Comprehension: an overlooked component in augmented language development.
Sevcik, Rose A
2006-02-15
Despite the importance of children's receptive skills as a foundation for later productive word use, the role of receptive language traditionally has received very limited attention since the focus in linguistic development has centered on language production. For children with significant developmental disabilities and communication impairments, augmented language systems have been devised as a tool both for language input and output. The role of both speech and symbol comprehension skills is emphasized in this paper. Data collected from two longitudinal studies of children and youth with severe disabilities and limited speech serve as illustrations in this paper. The acquisition and use of the System for Augmenting Language (SAL) was studied in home and school settings. Communication behaviors of the children and youth and their communication partners were observed and language assessment measures were collected. Two patterns of symbol learning and achievement--beginning and advanced--were observed. Extant speech comprehension skills brought to the augmented language learning task impacted the participants' patterns of symbol learning and use. Though often overlooked, the importance of speech and symbol comprehension skills were underscored in the studies described. Future areas for research are identified.
Li, Yingxin; Zhang, Xiaoxiao; Zhang, Chen; Zhang, Xiaoying; Li, Ying; Qi, Zhao; Szeto, Christopher; Tang, Mingxin; Peng, Yizhi; Molkentin, Jeffery D; Houser, Steven R; Xie, Mingxing; Chen, Xiongwen
2018-04-01
Cav3.1 T-type Ca 2+ channel current (I Ca-T ) contributes to heart rate genesis but is not known to contribute to heart rate regulation by the sympathetic/β-adrenergic system (SAS). We show that the loss of Cav3.1 makes the beating rates of the heart in vivo and perfused hearts ex vivo, as well as sinoatrial node cells, less sensitive to β-adrenergic stimulation; it also renders less conduction acceleration through the atrioventricular node by β-adrenergic stimulation. Increasing Cav3.1 in cardiomyocytes has the opposite effects. I Ca-T in sinoatrial nodal cells can be upregulated by β-adrenergic stimulation. The results of the present study add a new contribution to heart rate regulation by the SAS system and provide potential new mechanisms for the dysregulation of heart rate and conduction by the SAS in the heart. T-type Ca 2+ channel can be a target for heart disease treatments that aim to slow down the heart rate ABSTRACT: Cav3.1 (α 1G ) T-type Ca 2+ channel (TTCC) is expressed in mouse sinoatrial node cells (SANCs) and atrioventricular (AV) nodal cells and contributes to heart rate (HR) genesis and AV conduction. However, its role in HR regulation and AV conduction acceleration by the β-adrenergic system (SAS) is unclear. In the present study, L- (I Ca-L ) and T-type (I Ca-T ) Ca 2+ currents were recorded in SANCs from Cav3.1 transgenic (TG) and knockout (KO), and control mice. I Ca-T was absent in KO SANCs but enhanced in TG SANCs. In anaesthetized animals, different doses of isoproterenol (ISO) were infused via the jugular vein and the HR was recorded. The EC 50 of the HR response to ISO was lower in TG mice but higher in KO mice, and the maximal percentage of HR increase by ISO was greater in TG mice but less in KO mice. In Langendorff-perfused hearts, ISO increased HR and shortened PR intervals to a greater extent in TG but to a less extent in KO hearts. KO SANCs had significantly slower spontaneous beating rates than control SANCs before and after ISO; TG SANCs had similar basal beating rates as control SANCs probably as a result of decreased I Ca-L but a greater response to ISO than control SANCs. I Ca-T in SANCs was significantly increased by ISO. I Ca-T upregulation by β-adrenergic stimulation contributes to HR and conduction regulation by the SAS. TTCC can be a target for slowing the HR. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
Virtual interactive presence and augmented reality (VIPAR) for remote surgical assistance.
Shenai, Mahesh B; Dillavou, Marcus; Shum, Corey; Ross, Douglas; Tubbs, Richard S; Shih, Alan; Guthrie, Barton L
2011-03-01
Surgery is a highly technical field that combines continuous decision-making with the coordination of spatiovisual tasks. We designed a virtual interactive presence and augmented reality (VIPAR) platform that allows a remote surgeon to deliver real-time virtual assistance to a local surgeon, over a standard Internet connection. The VIPAR system consisted of a "local" and a "remote" station, each situated over a surgical field and a blue screen, respectively. Each station was equipped with a digital viewpiece, composed of 2 cameras for stereoscopic capture, and a high-definition viewer displaying a virtual field. The virtual field was created by digitally compositing selected elements within the remote field into the local field. The viewpieces were controlled by workstations mutually connected by the Internet, allowing virtual remote interaction in real time. Digital renderings derived from volumetric MRI were added to the virtual field to augment the surgeon's reality. For demonstration, a fixed-formalin cadaver head and neck were obtained, and a carotid endarterectomy (CEA) and pterional craniotomy were performed under the VIPAR system. The VIPAR system allowed for real-time, virtual interaction between a local (resident) and remote (attending) surgeon. In both carotid and pterional dissections, major anatomic structures were visualized and identified. Virtual interaction permitted remote instruction for the local surgeon, and MRI augmentation provided spatial guidance to both surgeons. Camera resolution, color contrast, time lag, and depth perception were identified as technical issues requiring further optimization. Virtual interactive presence and augmented reality provide a novel platform for remote surgical assistance, with multiple applications in surgical training and remote expert assistance.
USDA-ARS?s Scientific Manuscript database
Familial subvalvular aortic stenosis (SAS) is one of the most common congenital heart defects in dogs and is an inherited defect of Newfoundlands, golden retrievers and human children. Although SAS is known to be inherited, specific genes involved in Newfoundlands with SAS have not been defined. We ...
ERIC Educational Resources Information Center
Choi, Jinnie
2017-01-01
This article reviews PROC IRT, which was added to Statistical Analysis Software in 2014. We provide an introductory overview of a free version of SAS, describe what PROC IRT offers for item response theory (IRT) analysis and how one can use PROC IRT, and discuss how other SAS macros and procedures may compensate the IRT functionalities of PROC IRT.
Bootstrap Methods: A Very Leisurely Look.
ERIC Educational Resources Information Center
Hinkle, Dennis E.; Winstead, Wayland H.
The Bootstrap method, a computer-intensive statistical method of estimation, is illustrated using a simple and efficient Statistical Analysis System (SAS) routine. The utility of the method for generating unknown parameters, including standard errors for simple statistics, regression coefficients, discriminant function coefficients, and factor…
Reduced orexin immunoreactivity in Perry syndrome and multiple system atrophy.
Mishima, Takayasu; Kasanuki, Koji; Koga, Shunsuke; Castanedes-Casey, Monica; Wszolek, Zbigniew K; Tsuboi, Yoshio; Dickson, Dennis W
2017-09-01
Orexin is a neuropeptide that plays a key role in maintaining a state of arousal, and possibly associates with sleep apnea syndrome (SAS). Reduced orexin immunoreactivity has been reported in various neurologic conditions such as narcolepsy, Alzheimer's disease, Lewy body disease and multiple system atrophy (MSA); however, there has been no report investigating orexin in Perry syndrome, a rare hereditary neurodegenerative disease characterized by four clinical cardinal signs (parkinsonism, depression/apathy, weight loss, and central hypoventilation). Perry syndrome patients frequently have sleep disturbances, including SAS and insomnia. We evaluated orexin immunoreactivity in Perry syndrome. Using imaging analysis, we quantitatively assessed orexin immunoreactivity in the nucleus basalis of Meynert in three Perry syndrome cases, as well as five cases of frontotemporal lobar degeneration with motor neuron disease, five cases of MSA and five age-matched controls. For these cases, antemortem clinical information on sleep disturbances has been reviewed. In Perry syndrome and MSA, there was reduction of orexin immunoreactivity compared with controls (Perry syndrome: p = 0.020, MSA: p < 0.001). In contrast, FTLD-MND did not have significant reduction of orexin immunoreactivity. Two out of three cases of Perry syndrome had SAS confirmed by polysomnography. This is the first report assessing orexin immunoreactivity in Perry syndrome, and it showed significant reduction, similar to select neurodegenerative diseases, such as MSA. Further analysis with more cases will be needed to elucidate the specific mechanism of orexin loss in these disorders. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ju, Gawon; Yoon, In-Young; Lee, Sang Don; Kim, Yu Kyeong; Yoon, Eunjin; Kim, Jeong-Whun
2012-01-01
Decreased cerebral glucose metabolism has been reported in patients with sleep apnea syndrome (SAS), but it has yet to be decided whether cerebral glucose metabolism in SAS can be altered by continuous positive airway pressure (CPAP) treatment. The aim of this study was to evaluate cerebral glucose metabolism changes in patients with SAS after CPAP treatment. Thirteen middle-aged male patients with severe SAS [mean age 49.3 ± 7.2 years, mean apnea-hypopnea index (AHI) 60.4 ± 21.2] and 13 male controls (mean age 46.0 ± 9.4 years, mean AHI 4.1 ± 3.7) participated in the study. All 26 study subjects underwent fluorodeoxyglucose-positron emission tomography (FDG-PET), but SAS patients underwent FDG-PET twice, namely before and 3 months after acceptable CPAP usage. Significant hypometabolism was observed in the bilateral prefrontal areas, left cuneus and left cingulate cortex of SAS patients before CPAP, and after CPAP, significant increases in cortical glucose metabolism were observed in the bilateral precentral gyri and left anterior cingulate cortex. However, these improvements in hypometabolism in both areas were insufficient to reach control levels, and hypometabolism in other regions persisted after CPAP treatment. Reduced cerebral glucose metabolism in the precentral gyrus and the cingulate cortex in patients with SAS was modestly improved by acceptable CPAP treatment. The findings of this study suggest that acceptable CPAP usage cannot completely reverse reduced cerebral glucose metabolism in SAS patients. Further studies are required to evaluate the long-term effects of CPAP treatment with total compliance. Copyright © 2012 S. Karger AG, Basel.
Guzman, Oscar; Campbell, Noll L.; Walroth, Todd; Tricker, Jason L.; Hui, Siu L.; Perkins, Anthony; Zawahiri, Mohammed; Buckley, John D.; Farber, Mark O.; Ely, E. Wesley; Boustani, Malaz A.
2012-01-01
Background: Delirium evaluation in patients in the ICU requires the use of an arousal/sedation assessment tool prior to assessing consciousness. The Richmond Agitation-Sedation Scale (RASS) and the Riker Sedation-Agitation Scale (SAS) are well-validated arousal/sedation tools. We sought to assess the concordance of RASS and SAS assessments in determining eligibility of patients in the ICU for delirium screening using the confusion assessment method for the ICU (CAM-ICU). Methods: We performed a prospective cohort study in the adult medical, surgical, and progressive (step-down) ICUs of a tertiary care, university-affiliated, urban hospital in Indianapolis, Indiana. The cohort included 975 admissions to the ICU between January and October 2009. Results: The outcome measures of interest were the correlation and agreement between RASS and SAS measurements. In 2,469 RASS and SAS paired screens, the rank correlation using the Spearman correlation coefficient was 0.91, and the agreement between the two screening tools for assessing CAM-ICU eligibility as estimated by the κ coefficient was 0.93. Analysis showed that 70.1% of screens were eligible for CAM-ICU assessment using RASS (7.1% sedated [RASS −3 to −1]; 62.6% calm [0]; and 0.4% restless, agitated [+1 to +3]), compared with 72.1% using SAS (5% sedated [SAS 3]; 66.5% calm [4]; and 0.6% anxious, agitated [5, 6]). In the mechanically ventilated subgroup, RASS identified 19.1% CAM-ICU eligible patients compared with 24.6% by SAS. The correlation coefficient in this subgroup was 0.70 and the agreement was 0.81. Conclusion: Both SAS and RASS led to similar rates of delirium assessment using the CAM-ICU. PMID:22539644
Zheng, Xiangdong; Gooi, Li Ming; Wason, Arpit; Gabriel, Elke; Mehrjardi, Narges Zare; Yang, Qian; Zhang, Xingrun; Debec, Alain; Basiri, Marcus L.; Avidor-Reiss, Tomer; Pozniakovsky, Andrei; Poser, Ina; Šarić, Tomo; Hyman, Anthony A.; Li, Haitao; Gopalakrishnan, Jay
2014-01-01
Pericentriolar material (PCM) recruitment to centrioles forms a key step in centrosome biogenesis. Deregulation of this process leads to centrosome aberrations causing disorders, one of which is autosomal recessive primary microcephaly (MCPH), a neurodevelopmental disorder where brain size is reduced. During PCM recruitment, the conserved centrosomal protein Sas-4/CPAP/MCPH6, known to play a role in centriole formation, acts as a scaffold for cytoplasmic PCM complexes to bind and then tethers them to centrioles to form functional centrosomes. To understand Sas-4’s tethering role, we determined the crystal structure of its T complex protein 10 (TCP) domain displaying a solvent-exposed single-layer of β-sheets fold. This unique feature of the TCP domain suggests that it could provide an “extended surface-like” platform to tether the Sas-4–PCM scaffold to a centriole. Functional studies in Drosophila, human cells, and human induced pluripotent stem cell-derived neural progenitor cells were used to test this hypothesis, where point mutations within the 9–10th β-strands (β9–10 mutants including a MCPH-associated mutation) perturbed PCM tethering while allowing Sas-4/CPAP to scaffold cytoplasmic PCM complexes. Specifically, the Sas-4 β9–10 mutants displayed perturbed interactions with Ana2, a centrosome duplication factor, and Bld-10, a centriole microtubule-binding protein, suggesting a role for the β9–10 surface in mediating protein–protein interactions for efficient Sas-4–PCM scaffold centriole tethering. Hence, we provide possible insights into how centrosomal protein defects result in human MCPH and how Sas-4 proteins act as a vehicle to tether PCM complexes to centrioles independent of its well-known role in centriole duplication. PMID:24385583
SAS doctors career progression survey 2013.
Oroz, Carlos; Sands, Lorna R; Lee, John
2016-03-01
We conducted a national survey of Staff, Associate Specialists and Specialty (SAS) doctors working in sexual health clinics in the UK in 2013 in order to explore their career progression. The aim of the survey was to assess SAS doctors' experience in passing through the thresholds and to gather information about the adherence by SAS doctors and employers to the terms and conditions of service laid out by the new 2008 contract. Out of 185 responders, whom the authors estimate comprise 34% of the total workforce, 159 were on the new contract. Of those, most SAS doctors were women (84%), the majority (67%) worked less than nine programmed activities per week; only a few had intentions to join the consultant grade (15%), and a considerable minority (26%) were older than 54 years of age and likely to retire in the next ten years. The survey showed that most participating SAS doctors had undergone appraisal in the previous 15 months (90%), most had a job planning discussion (83%) with their employer and most had some allocated time for supporting professional activities (86%). However, a significant minority had no appraisal (10%), no job planning discussion (17%) and had no allocated supporting professional activities (14%), which allows time for career development in the specialty. Most SAS doctors, who had the opportunity, had progressed through the thresholds automatically (88%); some experienced difficulties in passing (8%) and only a few did not pass (4%). SAS doctors must ensure that they work together with their employer in order to improve adherence to the terms and conditions of service of the contract, which allow for career progression and benefit both the individual doctors and ultimately service provision. © The Author(s) 2015.
Preliminary Flight Results of a Fly-by-throttle Emergency Flight Control System on an F-15 Airplane
NASA Technical Reports Server (NTRS)
Burcham, Frank W., Jr.; Maine, Trindel A.; Fullerton, C. Gordon; Wells, Edward A.
1993-01-01
A multi-engine aircraft, with some or all of the flight control system inoperative, may use engine thrust for control. NASA Dryden has conducted a study of the capability and techniques for this emergency flight control method for the F-15 airplane. With an augmented control system, engine thrust, along with appropriate feedback parameters, is used to control flightpath and bank angle. Extensive simulation studies were followed by flight tests. The principles of throttles only control, the F-15 airplane, the augmented system, and the flight results including actual landings with throttles-only control are discussed.
Non-fragile multivariable PID controller design via system augmentation
NASA Astrophysics Data System (ADS)
Liu, Jinrong; Lam, James; Shen, Mouquan; Shu, Zhan
2017-07-01
In this paper, the issue of designing non-fragile H∞ multivariable proportional-integral-derivative (PID) controllers with derivative filters is investigated. In order to obtain the controller gains, the original system is associated with an extended system such that the PID controller design can be formulated as a static output-feedback control problem. By taking the system augmentation approach, the conditions with slack matrices for solving the non-fragile H∞ multivariable PID controller gains are established. Based on the results, linear matrix inequality -based iterative algorithms are provided to compute the controller gains. Simulations are conducted to verify the effectiveness of the proposed approaches.
Optical augmented reality assisted navigation system for neurosurgery teaching and planning
NASA Astrophysics Data System (ADS)
Wu, Hui-Qun; Geng, Xing-Yun; Wang, Li; Zhang, Yuan-Peng; Jiang, Kui; Tang, Le-Min; Zhou, Guo-Min; Dong, Jian-Cheng
2013-07-01
This paper proposed a convenient navigation system for neurosurgeon's pre-operative planning and teaching with augmented reality (AR) technique, which maps the three-dimensional reconstructed virtual anatomy structures onto a skull model. This system included two parts, a virtual reality system and a skull model scence. In our experiment, a 73 year old right-handed man initially diagnosed with astrocytoma was selected as an example to vertify our system. His imaging data from different modalities were registered and the skull soft tissue, brain and inside vessels as well as tumor were reconstructed. Then the reconstructed models were overlayed on the real scence. Our findings showed that the reconstructed tissues were augmented into the real scence and the registration results were in good alignment. The reconstructed brain tissue was well distributed in the skull cavity. The probe was used by a neurosurgeon to explore the surgical pathway which could be directly posed into the tumor while not injuring important vessels. In this way, the learning cost for students and patients' education about surgical risks reduced. Therefore, this system could be a selective protocol for image guided surgery(IGS), and is promising for neurosurgeon's pre-operative planning and teaching.
NASA Technical Reports Server (NTRS)
Urie, D. M.
1979-01-01
Relaxed static stability and stability augmentation with active controls were investigated for subsonic transport aircraft. Analytical and simulator evaluations were done using a contemporary wide body transport as a baseline. Criteria for augmentation system performance and unaugmented flying qualities were evaluated. Augmentation control laws were defined based on selected frequency response and time history criteria. Flying qualities evaluations were conducted by pilots using a moving base simulator with a transport cab. Static margin and air turbulence intensity were varied in test with and without augmentation. Suitability of a simple pitch control law was verified at neutral static margin in cruise and landing flight tasks. Neutral stability was found to be marginally acceptable in heavy turbulence in both cruise and landing conditions.
Assessment of In Situ Time Resolved Shock Experiments at Synchrotron Light Sources*
NASA Astrophysics Data System (ADS)
Belak, J.; Ilavsky, J.; Hessler, J. P.
2005-07-01
Prior to fielding in situ time resolved experiments of shock wave loading at the Advanced Photon Source, we have performed feasibility experiments assessing a single photon bunch. Using single and poly-crystal Al, Ti, V and Cu shock to incipient spallation on the gas gun, samples were prepared from slices normal to the spall plane of thickness 100-500 microns. In addition, single crystal Al of thickness 500 microns was shocked to incipient spallation and soft recovered using the LLNL e-gun mini-flyer system. The e-gun mini-flyer impacts the sample target producing a 10's ns flat-top shock transient. Here, we present results for imaging, small-angle scattering (SAS), and diffraction. In particular, there is little SAS away from the spall plane and significant SAS at the spall plane, demonstrating the presence of sub-micron voids. * Use of the Advanced Photon Source was supported by the U. S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. W-31-109-Eng-38 and work performed under the auspices of the U.S. Department of Energy by University of California, Lawrence Livermore National Laboratory under Contract W-7405-Eng-48.
Meyer, Nicole; Woidacki, Katja; Knöfler, Martin; Meinhardt, Gudrun; Nowak, Désirée; Velicky, Philipp; Pollheimer, Jürgen; Zenclussen, Ana C.
2017-01-01
Intrauterine growth restriction (IUGR) is caused by insufficient remodeling of spiral arteries (SAs). The mechanism underlying the relevance of natural killer cells (NKs) and mast cells (MCs) for SA remodeling and its effects on pregnancy outcome are not well understood. We show that NK depletion arrested SA remodeling without affecting pregnancy. MC depletion resulted in abnormally remodeled SAs and IUGR. Combined absence of NKs and MCs substantially affected SA remodeling and impaired fetal growth. We found that α-chymase mast cell protease (Mcpt) 5 mediates apoptosis of uterine smooth muscle cells, a key feature of SA remodeling. Additionally, we report a previously unknown source for Mcpt5: uterine (u) NKs. Mice with selective deletion of Mcpt5+ cells had un-remodeled SAs and growth-restricted progeny. The human α-chymase CMA1, phylogenetic homolog of Mcpt5, stimulated the ex vivo migration of human trophoblasts, a pre-requisite for SA remodeling. Our results show that chymases secreted by uMCs and uNKs are pivotal to the vascular changes required to support pregnancy. Understanding the mechanisms underlying pregnancy-induced vascular changes is essential for developing therapeutic options against pregnancy complications associated with poor vascular remodeling. PMID:28327604
Raglio, Alfredo; Gnesi, Marco; Monti, Maria Cristina; Oasi, Osmano; Gianotti, Marta; Attardo, Lapo; Gontero, Giulia; Morotti, Lara; Boffelli, Sara; Imbriani, Chiara; Montomoli, Cristina; Imbriani, Marcello
2017-11-01
Music therapy (MT) interventions are aimed at creating and developing a relationship between patient and therapist. However, there is a lack of validated observational instruments to consistently evaluate the MT process. The purpose of this study was the validation of Music Therapy Session Assessment Scale (MT-SAS), designed to assess the relationship between therapist and patient during active MT sessions. Videotapes of a single 30-min session per patient were considered. A pilot study on the videotapes of 10 patients was carried out to help refine the items, define the scoring system and improve inter-rater reliability among the five raters. Then, a validation study on 100 patients with different clinical conditions was carried out. The Italian MT-SAS was used throughout the process, although we also provide an English translation. The final scale consisted of 7 binary items accounting for eye contact, countenance, and nonverbal and sound-music communication. In the pilot study, raters were found to share an acceptable level of agreement in their assessments. Explorative factorial analysis disclosed a single homogeneous factor including 6 items (thus supporting an ordinal total score), with only the item about eye contact being unrelated to the others. Moreover, the existence of 2 different archetypal profiles of attuned and disattuned behaviours was highlighted through multiple correspondence analysis. As suggested by the consistent results of 2 different analyses, MT-SAS is a reliable tool that globally evaluates sonorous-musical and nonverbal behaviours related to emotional attunement and empathetic relationship between patient and therapist during active MT sessions. Copyright © 2017 John Wiley & Sons, Ltd.
Ahmad, Iqbal; Akhter, Sohail; Anwar, Mohammed; Zafar, Sobiya; Sharma, Rakesh Kumar; Ali, Asgar; Ahmad, Farhan Jalees
2017-05-15
The aim of this study was to develop Thymoquinone (TQ) loaded PEGylated liposomes using supercritical anti-solvent (SAS) process for enhanced blood circulation, and greater radioprotection. The SAS process of PEGylated liposomes synthesis was optimized by Box-Behnken design. Spherical liposomes with a particle size of 195.6±5.56nm and entrapment efficiency (%EE) of 89.4±3.69% were obtained. Optimized SAS process parameters; temperature, pressure and solution flow rate were 35°C, 140bar and 0.18mL/min, respectively, while 7.5mmol phospholipid, 0.75mmol of cholesterol, and 1mmol TQ were optimized formulation ingredients. Incorporation of MPEG-2000-DSPE (5% w/w) provided the PEGylated liposomes (FV-17B; particle size=231.3±6.74nm, %EE=91.9±3.45%, maximum TQ release >70% in 24h). Pharmacokinetics of FV-17B in mice demonstrated distinctly superior systemic circulation time for TQ in plasma. Effectiveness of radioprotection by FV-17B in mice model was demonstrated by non-significant body weight change, normal vital blood components (WBCs, RBCs, and Platelets), micronuclei and spleen index and increased survival probability in post irradiation animal group as compared to controls (plain TQ and marketed formulation). Altogether, the results anticipated that the SAS process could serve as a single step environmental friendly technique for the development of stable long circulating TQ loaded liposomes for effective radioprotection. Copyright © 2017 Elsevier B.V. All rights reserved.
De novo centriole formation in human cells is error-prone and does not require SAS-6 self-assembly
Wang, Won-Jing; Acehan, Devrim; Kao, Chien-Han; Jane, Wann-Neng; Uryu, Kunihiro; Tsou, Meng-Fu Bryan
2015-01-01
Vertebrate centrioles normally propagate through duplication, but in the absence of preexisting centrioles, de novo synthesis can occur. Consistently, centriole formation is thought to strictly rely on self-assembly, involving self-oligomerization of the centriolar protein SAS-6. Here, through reconstitution of de novo synthesis in human cells, we surprisingly found that normal looking centrioles capable of duplication and ciliation can arise in the absence of SAS-6 self-oligomerization. Moreover, whereas canonically duplicated centrioles always form correctly, de novo centrioles are prone to structural errors, even in the presence of SAS-6 self-oligomerization. These results indicate that centriole biogenesis does not strictly depend on SAS-6 self-assembly, and may require preexisting centrioles to ensure structural accuracy, fundamentally deviating from the current paradigm. DOI: http://dx.doi.org/10.7554/eLife.10586.001 PMID:26609813
Sb2O3/Ag/Sb2O3 Multilayer Transparent Conducting Films For Ultraviolet Organic Light-emitting Diode
NASA Astrophysics Data System (ADS)
Song, Chunyan; Zhang, Nan; Lin, Jie; Guo, Xiaoyang; Liu, Xingyuan
2017-01-01
A novel UV transparent conducting films based on Sb2O3/Ag/Sb2O3 (SAS) structure, which were prepared by an electron-beam thermal evaporation at room temperature. This SAS exhibits excellent electrical, optical and stable properties. Especially for UV region, the SAS has high transmittance of 80% at 306 nm and 92% at 335 nm, meanwhile achieving low sheet resistance ( ≤ 10 Ω sq-1). The UV OLED based on the SAS show competitive device performance. The UV OLED obtains the peak of UV electroluminescence at 376 nm and shows a very high maximum EQE of 4.1% with the maximum output power density of 5.18 mW cm-2. These results indicate that the potential of SAS applications in deep UV transparent electrodes and large-scale flexible transparent electronics.
Sb2O3/Ag/Sb2O3 Multilayer Transparent Conducting Films For Ultraviolet Organic Light-emitting Diode.
Song, Chunyan; Zhang, Nan; Lin, Jie; Guo, Xiaoyang; Liu, Xingyuan
2017-01-25
A novel UV transparent conducting films based on Sb 2 O 3 /Ag/Sb 2 O 3 (SAS) structure, which were prepared by an electron-beam thermal evaporation at room temperature. This SAS exhibits excellent electrical, optical and stable properties. Especially for UV region, the SAS has high transmittance of 80% at 306 nm and 92% at 335 nm, meanwhile achieving low sheet resistance ( ≤ 10 Ω sq -1 ). The UV OLED based on the SAS show competitive device performance. The UV OLED obtains the peak of UV electroluminescence at 376 nm and shows a very high maximum EQE of 4.1% with the maximum output power density of 5.18 mW cm -2 . These results indicate that the potential of SAS applications in deep UV transparent electrodes and large-scale flexible transparent electronics.
Sb2O3/Ag/Sb2O3 Multilayer Transparent Conducting Films For Ultraviolet Organic Light-emitting Diode
Song, Chunyan; Zhang, Nan; Lin, Jie; Guo, Xiaoyang; Liu, Xingyuan
2017-01-01
A novel UV transparent conducting films based on Sb2O3/Ag/Sb2O3 (SAS) structure, which were prepared by an electron-beam thermal evaporation at room temperature. This SAS exhibits excellent electrical, optical and stable properties. Especially for UV region, the SAS has high transmittance of 80% at 306 nm and 92% at 335 nm, meanwhile achieving low sheet resistance ( ≤ 10 Ω sq−1). The UV OLED based on the SAS show competitive device performance. The UV OLED obtains the peak of UV electroluminescence at 376 nm and shows a very high maximum EQE of 4.1% with the maximum output power density of 5.18 mW cm−2. These results indicate that the potential of SAS applications in deep UV transparent electrodes and large-scale flexible transparent electronics. PMID:28120888
Active glass-type human augmented cognition system considering attention and intention
NASA Astrophysics Data System (ADS)
Kim, Bumhwi; Ojha, Amitash; Lee, Minho
2015-10-01
Human cognition is the result of an interaction of several complex cognitive processes with limited capabilities. Therefore, the primary objective of human cognitive augmentation is to assist and expand these limited human cognitive capabilities independently or together. In this study, we propose a glass-type human augmented cognition system, which attempts to actively assist human memory functions by providing relevant, necessary and intended information by constantly assessing intention of the user. To achieve this, we exploit selective attention and intention processes. Although the system can be used in various real-life scenarios, we test the performance of the system in a person identity scenario. To detect the intended face, the system analyses the gaze points and change in pupil size to determine the intention of the user. An assessment of the gaze points and change in pupil size together indicates that the user intends to know the identity and information about the person in question. Then, the system retrieves several clues through speech recognition system and retrieves relevant information about the face, which is finally displayed through head-mounted display. We present the performance of several components of the system. Our results show that the active and relevant assistance based on users' intention significantly helps the enhancement of memory functions.
Comparison of Programs Used for FIA Inventory Information Dissemination and Spatial Representation
Roger C. Lowe; Chris J. Cieszewski
2005-01-01
Six online applications developed for the interactive display of Forest Inventory and Analysis (FIA) data in which FIA database information and query results can be viewed as or selected from interactive geographic maps are compared. The programs evaluated are the U.S. Department of Agriculture Forest Service?s online systems; a SAS server-based mapping system...
Ranky, Richard G; Sivak, Mark L; Lewis, Jeffrey A; Gade, Venkata K; Deutsch, Judith E; Mavroidis, Constantinos
2014-06-05
Cycling has been used in the rehabilitation of individuals with both chronic and post-surgical conditions. Among the challenges with implementing bicycling for rehabilitation is the recruitment of both extremities, in particular when one is weaker or less coordinated. Feedback embedded in virtual reality (VR) augmented cycling may serve to address the requirement for efficacious cycling; specifically recruitment of both extremities and exercising at a high intensity. In this paper a mechatronic rehabilitation bicycling system with an interactive virtual environment, called Virtual Reality Augmented Cycling Kit (VRACK), is presented. Novel hardware components embedded with sensors were implemented on a stationary exercise bicycle to monitor physiological and biomechanical parameters of participants while immersing them in an augmented reality simulation providing the user with visual, auditory and haptic feedback. This modular and adaptable system attaches to commercially-available stationary bicycle systems and interfaces with a personal computer for simulation and data acquisition processes. The complete bicycle system includes: a) handle bars based on hydraulic pressure sensors; b) pedals that monitor pedal kinematics with an inertial measurement unit (IMU) and forces on the pedals while providing vibratory feedback; c) off the shelf electronics to monitor heart rate and d) customized software for rehabilitation. Bench testing for the handle and pedal systems is presented for calibration of the sensors detecting force and angle. The modular mechatronic kit for exercise bicycles was tested in bench testing and human tests. Bench tests performed on the sensorized handle bars and the instrumented pedals validated the measurement accuracy of these components. Rider tests with the VRACK system focused on the pedal system and successfully monitored kinetic and kinematic parameters of the rider's lower extremities. The VRACK system, a virtual reality mechatronic bicycle rehabilitation modular system was designed to convert most bicycles in virtual reality (VR) cycles. Preliminary testing of the augmented reality bicycle system was successful in demonstrating that a modular mechatronic kit can monitor and record kinetic and kinematic parameters of several riders.
O'Connor, Timothy; Rawat, Siddharth; Markman, Adam; Javidi, Bahram
2018-03-01
We propose a compact imaging system that integrates an augmented reality head mounted device with digital holographic microscopy for automated cell identification and visualization. A shearing interferometer is used to produce holograms of biological cells, which are recorded using customized smart glasses containing an external camera. After image acquisition, segmentation is performed to isolate regions of interest containing biological cells in the field-of-view, followed by digital reconstruction of the cells, which is used to generate a three-dimensional (3D) pseudocolor optical path length profile. Morphological features are extracted from the cell's optical path length map, including mean optical path length, coefficient of variation, optical volume, projected area, projected area to optical volume ratio, cell skewness, and cell kurtosis. Classification is performed using the random forest classifier, support vector machines, and K-nearest neighbor, and the results are compared. Finally, the augmented reality device displays the cell's pseudocolor 3D rendering of its optical path length profile, extracted features, and the identified cell's type or class. The proposed system could allow a healthcare worker to quickly visualize cells using augmented reality smart glasses and extract the relevant information for rapid diagnosis. To the best of our knowledge, this is the first report on the integration of digital holographic microscopy with augmented reality devices for automated cell identification and visualization.
Social Anxiety Scale for Adolescents (SAS-A): Measuring Social Anxiety among Finnish Adolescents
ERIC Educational Resources Information Center
Ranta, Klaus; Junttila, Niina; Laakkonen, Eero; Uhmavaara, Anni; La Greca, Annette M.; Niemi, Paivi M.
2012-01-01
The aim of this study was to investigate symptoms of social anxiety and the psychometric properties of the "Social Anxiety Scale for Adolescents" (SAS-A) among Finnish adolescents, 13-16 years of age. Study 1 (n = 867) examined the distribution of SAS-A scores according to gender and age, and the internal consistency and factor structure…
ERIC Educational Resources Information Center
Travers, Jason C.; Fefer, Sarah A.
2017-01-01
Shared active surface (SAS) technology can be described as a supersized tablet computer for multiple simultaneous users. SAS technology has the potential to resolve issues historically associated with learning via single-user computer technology. This study reports findings of a SAS on the social communication and nonsocial speech of two preschool…
Structures of SAS-6 suggest its organization in centrioles.
van Breugel, Mark; Hirono, Masafumi; Andreeva, Antonina; Yanagisawa, Haru-aki; Yamaguchi, Shoko; Nakazawa, Yuki; Morgner, Nina; Petrovich, Miriana; Ebong, Ima-Obong; Robinson, Carol V; Johnson, Christopher M; Veprintsev, Dmitry; Zuber, Benoît
2011-03-04
Centrioles are cylindrical, ninefold symmetrical structures with peripheral triplet microtubules strictly required to template cilia and flagella. The highly conserved protein SAS-6 constitutes the center of the cartwheel assembly that scaffolds centrioles early in their biogenesis. We determined the x-ray structure of the amino-terminal domain of SAS-6 from zebrafish, and we show that recombinant SAS-6 self-associates in vitro into assemblies that resemble cartwheel centers. Point mutations are consistent with the notion that centriole formation in vivo depends on the interactions that define the self-assemblies observed here. Thus, these interactions are probably essential to the structural organization of cartwheel centers.
Hemispheric Sunspot Unit Area: Comparison with Hemispheric Sunspot Number and Sunspot Area
NASA Astrophysics Data System (ADS)
Li, K. J.; Xiang, N. B.; Qu, Z. N.; Xie, J. L.
2014-03-01
The monthly mean northern and southern hemispheric sunspot numbers (SNs) and sunspot areas (SAs) in the time interval of 1945 January to 2012 December are utilized to construct the monthly northern and southern hemispheric sunspot unit areas (SUAs), which are defined as the ratio of hemispheric SA to SN. Hemispheric SUAs are usually found to rise at the beginning and to fall at the ending time of a solar cycle more rapidly, forming a more irregular cycle profile than hemispheric SNs and SAs, although it also presents Schwabe-cycle-like hemispheric SNs and SAs. Sunspot activity (SN, SA, and SUA) is found asynchronously and is asymmetrically distributed in the northern and southern hemispheres, and hemispheric SNs, SAs, and SUAs are not in phase in the two hemispheres. The similarity of hemispheric SNs and SAs is found to be much more obvious than that of hemispheric SUAs and SNs (or SAs), and also for their north-south asymmetry. A notable feature is found for the behavior of the SUA around the minimum time of cycle 24: the SUA rapidly decreases from the cycle maximum value to the cycle minimum value of sunspot cycles 19-24 within just 22 months.
Hemispheric sunspot unit area: comparison with hemispheric sunspot number and sunspot area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, K. J.; Xiang, N. B.; Qu, Z. N.
2014-03-01
The monthly mean northern and southern hemispheric sunspot numbers (SNs) and sunspot areas (SAs) in the time interval of 1945 January to 2012 December are utilized to construct the monthly northern and southern hemispheric sunspot unit areas (SUAs), which are defined as the ratio of hemispheric SA to SN. Hemispheric SUAs are usually found to rise at the beginning and to fall at the ending time of a solar cycle more rapidly, forming a more irregular cycle profile than hemispheric SNs and SAs, although it also presents Schwabe-cycle-like hemispheric SNs and SAs. Sunspot activity (SN, SA, and SUA) is foundmore » asynchronously and is asymmetrically distributed in the northern and southern hemispheres, and hemispheric SNs, SAs, and SUAs are not in phase in the two hemispheres. The similarity of hemispheric SNs and SAs is found to be much more obvious than that of hemispheric SUAs and SNs (or SAs), and also for their north-south asymmetry. A notable feature is found for the behavior of the SUA around the minimum time of cycle 24: the SUA rapidly decreases from the cycle maximum value to the cycle minimum value of sunspot cycles 19-24 within just 22 months.« less
Modification of solid-state property of sulfasalazine by using the supercritical antisolvent process
NASA Astrophysics Data System (ADS)
Wu, Wei-Yi; Su, Chie-Shaan
2017-02-01
In this study, the supercritical antisolvent (SAS) process was used to recrystallize an active pharmaceutical ingredient, sulfasalazine, to modify the solid-state properties including particle size, crystal habit and polymorphic form. Supercritical CO2 and tetrahydrofuran were used as the antisolvent and solvent, respectively. SAS results obtained from different operating temperatures (35, 45, 55 and 65 °C) were compared and discussed. The results indicate that at 55 °C, spherical sulfasalazine crystals were produced and that their mean particle size was micronized to approximately 1 μm. In addition, according to the analytical results of powder X-ray diffractometry (PXRD), a novel polymorphic form of sulfasalazine was obtained after SAS. Furthermore, the spectroscopic and thermal behavior of produced sulfasalazine crystals were also studied by Fourier transform infrared spectrometry (FTIR), differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Finally, SAS results obtained from different operating temperature was discussed on the basis of the mixture critical point (MCP) of CO2 and tetrahydrofuran. Operation at slightly higher than the MCP is favorable for recrystallization of sulfasalazine through SAS. These results demonstrate that the SAS process is an efficient tool for controlling and modifying the solid-state property of sulfasalazine.
Thrust Augmentation Measurements for a Pulse Detonation Engine Driven Ejector
NASA Technical Reports Server (NTRS)
Pal, S.; Santoro, Robert J.; Shehadeh, R.; Saretto, S.; Lee, S.-Y.
2005-01-01
Thrust augmentation results of an ongoing study of pulse detonation engine driven ejectors are presented and discussed. The experiments were conducted using a pulse detonation engine (PDE) setup with various ejector configurations. The PDE used in these experiments utilizes ethylene (C2H4) as the fuel, and an equi-molar mixture of oxygen and nitrogen as the oxidizer at an equivalence ratio of one. High fidelity thrust measurements were made using an integrated spring damper system. The baseline thrust of the PDE engine was first measured and agrees with experimental and modeling results found in the literature. Thrust augmentation measurements were then made for constant diameter ejectors. The parameter space for the study included ejector length, PDE tube exit to ejector tube inlet overlap distance, and straight versus rounded ejector inlets. The relationship between the thrust augmentation results and various physical phenomena is described. To further understand the flow dynamics, shadow graph images of the exiting shock wave front from the PDE were also made. For the studied parameter space, the results showed a maximum augmentation of 40%. Further increase in augmentation is possible if the geometry of the ejector is tailored, a topic currently studied by numerous groups in the field.
Methodology, Methods, and Metrics for Testing and Evaluating Augmented Cognition Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greitzer, Frank L.
The augmented cognition research community seeks cognitive neuroscience-based solutions to improve warfighter performance by applying and managing mitigation strategies to reduce workload and improve the throughput and quality of decisions. The focus of augmented cognition mitigation research is to define, demonstrate, and exploit neuroscience and behavioral measures that support inferences about the warfighter’s cognitive state that prescribe the nature and timing of mitigation. A research challenge is to develop valid evaluation methodologies, metrics and measures to assess the impact of augmented cognition mitigations. Two considerations are external validity, which is the extent to which the results apply to operational contexts;more » and internal validity, which reflects the reliability of performance measures and the conclusions based on analysis of results. The scientific rigor of the research methodology employed in conducting empirical investigations largely affects the validity of the findings. External validity requirements also compel us to demonstrate operational significance of mitigations. Thus it is important to demonstrate effectiveness of mitigations under specific conditions. This chapter reviews some cognitive science and methodological considerations in designing augmented cognition research studies and associated human performance metrics and analysis methods to assess the impact of augmented cognition mitigations.« less
New-generation diabetes management: glucose sensor-augmented insulin pump therapy
Cengiz, Eda; Sherr, Jennifer L; Weinzimer, Stuart A; Tamborlane, William V
2011-01-01
Diabetes is one of the most common chronic disorders with an increasing incidence worldwide. Technologic advances in the field of diabetes have provided new tools for clinicians to manage this challenging disease. For example, the development of continuous subcutaneous insulin infusion systems have allowed for refinement in the delivery of insulin, while continuous glucose monitors provide patients and clinicians with a better understanding of the minute to minute glucose variability, leading to the titration of insulin delivery based on this variability when applicable. Merging of these devices has resulted in sensor-augmented insulin pump therapy, which became a major building block upon which the artificial pancreas (closed-loop systems) can be developed. This article summarizes the evolution of sensor-augmented insulin pump therapy until present day and its future applications in new-generation diabetes management. PMID:21728731
New-generation diabetes management: glucose sensor-augmented insulin pump therapy.
Cengiz, Eda; Sherr, Jennifer L; Weinzimer, Stuart A; Tamborlane, William V
2011-07-01
Diabetes is one of the most common chronic disorders with an increasing incidence worldwide. Technologic advances in the field of diabetes have provided new tools for clinicians to manage this challenging disease. For example, the development of continuous subcutaneous insulin infusion systems have allowed for refinement in the delivery of insulin, while continuous glucose monitors provide patients and clinicians with a better understanding of the minute to minute glucose variability, leading to the titration of insulin delivery based on this variability when applicable. Merging of these devices has resulted in sensor-augmented insulin pump therapy, which became a major building block upon which the artificial pancreas (closed-loop systems) can be developed. This article summarizes the evolution of sensor-augmented insulin pump therapy until present day and its future applications in new-generation diabetes management.
An analysis of a candidate control algorithm for a ride quality augmentation system
NASA Technical Reports Server (NTRS)
Suikat, Reiner; Donaldson, Kent; Downing, David R.
1987-01-01
This paper presents a detailed analysis of a candidate algorithm for a ride quality augmentation system. The algorithm consists of a full-state feedback control law based on optimal control output weighting, estimators for angle of attack and sideslip, and a maneuvering algorithm. The control law is shown to perform well by both frequency and time domain analysis. The rms vertical acceleration is reduced by about 40 percent over the whole mission flight envelope. The estimators for the angle of attack and sideslip avoid the often inaccurate or costly direct measurement of those angles. The maneuvering algorithm will allow the augmented airplane to respond to pilot inputs. The design characteristics and performance are documented by the closed-loop eigenvalues; rms levels of vertical, lateral, and longitudinal acceleration; and representative time histories and frequency response.
Magnetohydrodynamic Augmented Propulsion Experiment: I. Performance Analysis and Design
NASA Technical Reports Server (NTRS)
Litchford, R. J.; Cole, J. W.; Lineberry, J. T.; Chapman, J. N.; Schmidt, H. J.; Lineberry, C. W.
2003-01-01
The performance of conventional thermal propulsion systems is fundamentally constrained by the specific energy limitations associated with chemical fuels and the thermal limits of available materials. Electromagnetic thrust augmentation represents one intriguing possibility for improving the fuel composition of thermal propulsion systems, thereby increasing overall specific energy characteristics; however, realization of such a system requires an extremely high-energy-density electrical power source as well as an efficient plasma acceleration device. This Technical Publication describes the development of an experimental research facility for investigating the use of cross-field magnetohydrodynamic (MHD) accelerators as a possible thrust augmentation device for thermal propulsion systems. In this experiment,a 1.5-MW(sub e) Aerotherm arc heater is used to drive a 2-MW(sub e) MHD accelerator. The heatsink MHD accelerator is configured as an externally diagonalized, segmented channel, which is inserted into a large-bore, 2-T electromagnet. The performance analysis and engineering design of the flow path are described as well as the parameter measurements and flow diagnostics planned for the initial series of test runs.
An augmented magnetic navigation system for Transcatheter Aortic Valve Implantation.
Luo, Zhe; Cai, Junfeng; Nie, Yuanyuan; Wang, Guotai; Gu, Lixu
2013-01-01
This research proposes an augmented magnetic navigation system for Transcatheter Aortic Valve Implantation (TAVI) employing a magnetic tracking system (MTS) combined with a dynamic aortic model and intra-operative ultrasound (US) images. The dynamic 3D aortic model is constructed based on the preoperative 4D computed tomography (CT), which is animated according to the real time electrocardiograph (ECG) input of patient. And a preoperative planning is performed to determine the target position of the aortic valve prosthesis. The temporal alignment is performed to synchronize the ECG signals, intra-operative US image and tracking information. Afterwards, with the assistance of synchronized ECG signals, the contour of aortic root automatic extracted from short axis US image is registered to the dynamic aortic model by a feature based registration intra-operatively. Then the augmented MTS guides the interventionist to confidently position and deploy the aortic valve prosthesis to target. The system was validated by animal studies on three porcine subjects, the deployment and tilting errors of which are 3.17 ± 0.91 mm and 7.40 ± 2.89° respectively.
Comparing two types of augmentative and alternative communication systems for children with autism.
Son, Seung-Hyun; Sigafoos, Jeff; O'Reilly, Mark; Lancioni, Giulio E
2006-01-01
This study compared acquisition and preference for two types of augmentative and alternative communication (AAC) systems in three pre-schoolers with autism. Acquisition of requesting behaviour using a picture-exchange system vs a voice-output communication aide (VOCA) was compared in an alternating treatments design. Following acquisition, both ACC systems were simultaneously available and the child could select which one of the two systems to use. There was little difference between picture-exchange and VOCA in terms of acquisition rates. Two children demonstrated a consistent preference for picture-exchange and the third showed a preference for the VOCA. Both speed of acquisition and system preference should be considered when designing AAC interventions for children with autism and related developmental disabilities.
Flow interaction of diffuser augmented wind turbines
NASA Astrophysics Data System (ADS)
Göltenbott, U.; Ohya, Y.; Yoshida, S.; Jamieson, P.
2016-09-01
Up-scaling of wind turbines has been a major trend in order to reduce the cost of energy generation from the wind. Recent studies however show that for a given technology, the cost always rises with upscaling, notably due to the increased mass of the system. To reach capacities beyond 10 MW, multi-rotor systems (MRS) have promising advantages. On the other hand, diffuser augmented wind turbines (DAWTs) can significantly increase the performance of the rotor. Up to now, diffuser augmentation has only been applied to single small wind turbines. In the present research, DAWTs are used in a multi-rotor system. In wind tunnel experiments, the aerodynamics of two and three DAWTs, spaced in close vicinity in the same plane normal to a uniform flow, have been analysed. Power increases of up to 5% and 9% for the two and three rotor configurations are respectively achieved in comparison to a stand-alone turbine. The physical dynamics of the flows are analysed on the basis of the results obtained with a stand-alone turbine.
Murugesan, Yahini Prabha; Alsadoon, Abeer; Manoranjan, Paul; Prasad, P W C
2018-06-01
Augmented reality-based surgeries have not been successfully implemented in oral and maxillofacial areas due to limitations in geometric accuracy and image registration. This paper aims to improve the accuracy and depth perception of the augmented video. The proposed system consists of a rotational matrix and translation vector algorithm to reduce the geometric error and improve the depth perception by including 2 stereo cameras and a translucent mirror in the operating room. The results on the mandible/maxilla area show that the new algorithm improves the video accuracy by 0.30-0.40 mm (in terms of overlay error) and the processing rate to 10-13 frames/s compared to 7-10 frames/s in existing systems. The depth perception increased by 90-100 mm. The proposed system concentrates on reducing the geometric error. Thus, this study provides an acceptable range of accuracy with a shorter operating time, which provides surgeons with a smooth surgical flow. Copyright © 2018 John Wiley & Sons, Ltd.
DOT National Transportation Integrated Search
1996-06-01
This manual has been developed to provide information and guidance to engineering staffs involved with project develop and design of highways. It identifies those standards, specifications, guides, and references approved for use in carrying out the ...
DOT National Transportation Integrated Search
2012-05-05
As part of the Federal Highway Administration (FHWA) Traffic Analysis Toolbox (Volume XIII), this guide was designed to help corridor stakeholders implement the ICM AMS methodology successfully and effectively. It provides a step-by-step approach to ...
ERIC Educational Resources Information Center
Gavish, Nirit; Gutiérrez, Teresa; Webel, Sabine; Rodríguez, Jorge; Peveri, Matteo; Bockholt, Uli; Tecchia, Franco
2015-01-01
The current study evaluated the use of virtual reality (VR) and augmented reality (AR) platforms, developed within the scope of the SKILLS Integrated Project, for industrial maintenance and assembly (IMA) tasks training. VR and AR systems are now widely regarded as promising training platforms for complex and highly demanding IMA tasks. However,…
An Augmented Lecture Feedback System to Support Learner and Teacher Communication
ERIC Educational Resources Information Center
Zarraonandia, Telmo; Aedo, Ignacio; Diaz, Paloma; Montero, Alvaro
2013-01-01
In this paper, it is advocated that the feedback loop between learners and teachers could be improved by making use of augmented reality (AR) techniques. The bidirectional communication between teacher and learners is sometimes hampered by students' fear of showing themselves up in front of their classmates. In order to overcome this problem, a…
NASA Astrophysics Data System (ADS)
Nono, O. H.; Natawidjaja, R.; Arief, B.; Suryadi, D.; Kapa, M. M. J.
2018-02-01
The aim of this study was to analyse the impact of sharing arrangement systems to performance of beef cattle breeding. This research was conducted in Kupang Regency - East Nusa Tenggara Province, Indonesia. The study used multi stage cluster random sampling method to determine the sample area and respondents. The sample areas consisted of 2 sub-districts and 6 villages, while the total respondents were 117 people comprised 74 Participant Farmers (PF) of sharing arrangement systems (SAS) and 43 non-participant farmers (NPF). 23 investors were selected for the survey. The result of the study indicated that the performance of NPF in terms of revenue, net profit, and return on investment (ROI) was better than PF respondents. The value of ROI was between 16.69-32.23 %. This indicated that utilization of farm asset was not optimum yet. It was found that farm efficiency was 1.73 which indicated that SAS does not increase farm productivity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jankovsky, Zachary Kyle; Denman, Matthew R.
It is difficult to assess the consequences of a transient in a sodium-cooled fast reactor (SFR) using traditional probabilistic risk assessment (PRA) methods, as numerous safety-related sys- tems have passive characteristics. Often there is significant dependence on the value of con- tinuous stochastic parameters rather than binary success/failure determinations. One form of dynamic PRA uses a system simulator to represent the progression of a transient, tracking events through time in a discrete dynamic event tree (DDET). In order to function in a DDET environment, a simulator must have characteristics that make it amenable to changing physical parameters midway through themore » analysis. The SAS4A SFR system analysis code did not have these characteristics as received. This report describes the code modifications made to allow dynamic operation as well as the linking to a Sandia DDET driver code. A test case is briefly described to demonstrate the utility of the changes.« less
Development and Validation of a Smartphone Addiction Scale (SAS)
Kwon, Min; Lee, Joon-Yeop; Won, Wang-Youn; Park, Jae-Woo; Min, Jung-Ah; Hahn, Changtae; Gu, Xinyu; Choi, Ji-Hye; Kim, Dai-Jin
2013-01-01
Objective The aim of this study was to develop a self-diagnostic scale that could distinguish smartphone addicts based on the Korean self-diagnostic program for Internet addiction (K-scale) and the smartphone's own features. In addition, the reliability and validity of the smartphone addiction scale (SAS) was demonstrated. Methods A total of 197 participants were selected from Nov. 2011 to Jan. 2012 to accomplish a set of questionnaires, including SAS, K-scale, modified Kimberly Young Internet addiction test (Y-scale), visual analogue scale (VAS), and substance dependence and abuse diagnosis of DSM-IV. There were 64 males and 133 females, with ages ranging from 18 to 53 years (M = 26.06; SD = 5.96). Factor analysis, internal-consistency test, t-test, ANOVA, and correlation analysis were conducted to verify the reliability and validity of SAS. Results Based on the factor analysis results, the subscale “disturbance of reality testing” was removed, and six factors were left. The internal consistency and concurrent validity of SAS were verified (Cronbach's alpha = 0.967). SAS and its subscales were significantly correlated with K-scale and Y-scale. The VAS of each factor also showed a significant correlation with each subscale. In addition, differences were found in the job (p<0.05), education (p<0.05), and self-reported smartphone addiction scores (p<0.001) in SAS. Conclusions This study developed the first scale of the smartphone addiction aspect of the diagnostic manual. This scale was proven to be relatively reliable and valid. PMID:23468893
Development and validation of a smartphone addiction scale (SAS).
Kwon, Min; Lee, Joon-Yeop; Won, Wang-Youn; Park, Jae-Woo; Min, Jung-Ah; Hahn, Changtae; Gu, Xinyu; Choi, Ji-Hye; Kim, Dai-Jin
2013-01-01
The aim of this study was to develop a self-diagnostic scale that could distinguish smartphone addicts based on the Korean self-diagnostic program for Internet addiction (K-scale) and the smartphone's own features. In addition, the reliability and validity of the smartphone addiction scale (SAS) was demonstrated. A total of 197 participants were selected from Nov. 2011 to Jan. 2012 to accomplish a set of questionnaires, including SAS, K-scale, modified Kimberly Young Internet addiction test (Y-scale), visual analogue scale (VAS), and substance dependence and abuse diagnosis of DSM-IV. There were 64 males and 133 females, with ages ranging from 18 to 53 years (M = 26.06; SD = 5.96). Factor analysis, internal-consistency test, t-test, ANOVA, and correlation analysis were conducted to verify the reliability and validity of SAS. Based on the factor analysis results, the subscale "disturbance of reality testing" was removed, and six factors were left. The internal consistency and concurrent validity of SAS were verified (Cronbach's alpha = 0.967). SAS and its subscales were significantly correlated with K-scale and Y-scale. The VAS of each factor also showed a significant correlation with each subscale. In addition, differences were found in the job (p<0.05), education (p<0.05), and self-reported smartphone addiction scores (p<0.001) in SAS. This study developed the first scale of the smartphone addiction aspect of the diagnostic manual. This scale was proven to be relatively reliable and valid.
Factors associated with severity of sleep apnoea syndrome in patients with chronic kidney disease.
Tanaka, Akihito; Inaguma, Daijo; Ito, Eri; Kamegai, Naoki; Kato, Akiko; Mizutani, Minami; Shimogushi, Hiroya; Shinjo, Hibiki; Otsuka, Yasuhiro; Takeda, Asami
2017-08-01
Background In patients with chronic kidney disease (CKD), prevalence of sleep apnoea syndrome (SAS) is reported to be markedly high. However, the factors associated with severity of SAS in such patients rarely have been reported. Methods This was a cross-sectional study of 100 stable non-dialysis patients with CKD who attended a CKD educational programme from April 2014 to August 2015. Diagnosis of SAS and its severity were assessed using a type-3 portable monitor. Results Eighty-six men and 14 women with a mean age of 71.6 ± 9.7 years were included. Mean apnoea-hypopnoea index (AHI) was 26.0 ± 13.8. Severe SAS was seen in 39 patients. Significant differences in brain natriuretic peptide (BNP) level (213.6 ± 329.6 pg/mL vs 107.8 ± 141.3 pg/mL, P < 0.05) and cardiothoracic ratio (CTR, 52.4% ± 6.3% vs 49.6% ± 5.7%, P < 0.05) were seen between patients with and without severe SAS. After adjusting for various parameters, BNP level, CTR, and diameter of the inferior vena cava at the end of inhalation were found to correlate with AHI. Conclusions In patients with CKD, prevalence of severe SAS is extremely high. In these patients, fluid retention, rather than systolic or diastolic function, correlates with severity of SAS.